WorldWideScience

Sample records for fire resistance design

  1. Design of fire resistant concrete structures, using validated Fem models

    NARCIS (Netherlands)

    Erich, S.J.F.; Overbeek, van A.B.M.; Heijden, van der G.H.A.; Pel, L.; Huinink, H.P.; Vervuurt, A.H.J.M.; Schlangen, E.; Schlutter, de G.

    2008-01-01

    Fire safety of buildings and structures is an important issue, and has a great impact on human life and economy. One of the processes negatively affecting the strength of a concrete building or structure during fire is spalling. Many examples exists in which spalling of concrete during fire has

  2. Optimizing Organophosphorus Fire Resistant Finish for Cotton Fabric Using Box-Behnken Design

    International Nuclear Information System (INIS)

    Sohail, Y.; Parag, B.; Nemeshwaree, B.; Giorgio, R.

    2016-01-01

    N-methylol dimethyl phosphono propionamide (MDPA) is one of the most utilized fire resistant (FR) finishes for cotton fabrics, utilized as part of a formulation with trimethylol melamine (TMM) to acquire better crosslinking and enhanced FR properties. The system parameters of the finishing treatment were upgraded for better FR properties and low mechanical loss to the fabric by the response surface methodology utilizing Box-Behnken statistical designed experimental strategy. The impacts of concentration on the cotton fabric’s properties (fire resistance and mechanical properties) were assessed with the regression equations. The optimum conditions by predicting the FR reagents focusing intact mechanical properties of the fabric were additionally studied. It was found that the parameters of crosslinking agents in the FR formulation have a prime role in the general FR properties of the cotton fabrics. The R-squared estimations of the considerable number of responses were above 92%, demonstrating the level of relationship between the predicted values by the Box-Behnken frameworks and the real test results.

  3. Study to develop improved fire resistant aircraft passenger seat materials

    Science.gov (United States)

    Duskin, F. E.; Schutter, K. J.; Sieth, H. H.; Trabold, E. L.

    1980-01-01

    The Phase 3 study of the NASA 'Improved Fire Resistant Aircraft Seat Materials' involved fire tests of improved materials in multilayered combinations representative of cushion configurations. Tests were conducted to determine their thermal, smoke, and fire resistance characteristics. Additionally, a 'Design Guideline' for Fire Resistant Passenger Seats was written outlining general seat design considerations. Finally, a three-abreast 'Tourist Class' passenger seat assembly fabricated from the most advanced fire-resistant materials was delivered.

  4. Fire Resistant, Moisture Barrier Membrane

    Science.gov (United States)

    St.Clair, Terry L. (Inventor)

    2000-01-01

    A waterproof and breathable, fire-resistant laminate is provided for use in tents, garments, shoes, and covers, especially in industrial, military and emergency situations. The laminate permits water vapor evaporation while simultaneously preventing liquid water penetration. Further, the laminate is fire-resistant and significantly reduces the danger of toxic compound production when exposed to flame or other high heat source. The laminate may be applied to a variety of substrates and is comprised of a silicone rubber and plurality of fire-resistant, inherently thermally-stable polyimide particles.

  5. Stronger Fire-Resistant Epoxies

    Science.gov (United States)

    Fohlen, George M.; Parker, John A.; Kumar, Devendra

    1988-01-01

    New curing agent improves mechanical properties and works at lower temperature. Use of aminophenoxycyclotriphosphazene curing agents yields stronger, more heat- and fire-resistant epoxy resins. Used with solvent if necessary for coating fabrics or casting films.

  6. Fire Resistant Materials

    Science.gov (United States)

    1982-01-01

    Fire hazard is greater in atmospheres containing a high percentage of oxygen under pressure. NASA intensified its fire safety research after a 1967 Apollo fire. A chemically treated fabric called Durette developed by Monsanto Company, which will not burn or produce noxious fumes, was selected as a material for Apollo astronaut garments. Monsanto sold production rights for this material to Fire Safe Products (FSP). Durette is now used for a wide range of applications such as: sheets, attendants' uniforms in hyperbaric chambers; crew's clothing, furniture and interior walls of diving chambers operated by the U.S. Navy and other oceanographic companies and research organizations. Pyrotect Safety Equipment, Minneapolis, MN produces Durette suits for auto racers, refuelers and crew chiefs from material supplied by FSP. FSP also manufactures Durette bags for filtering gases and dust from boilers, electric generators and similar systems. Durette bags are an alternative to other felted fiber capable of operating at high temperature that cost twice as much.

  7. Fire Models and Design Fires

    DEFF Research Database (Denmark)

    Poulsen, Annemarie

    The aim of this project is to perform an experimental study on the influence of the thermal feedback on the burning behavior of well ventilated pre-flashover fires. For the purpose an experimental method has been developed. Here the same identical objects are tested under free burn conditions...... carried out by Carleton University and NRC-IRC performed on seven different types of fire loads representing commercial premises, comprise the tests used for the study. The results show that for some of the room test the heat release rate increased due to thermal feedback compared to free burn for a pre......-flashover fire. Two phenomena were observed, that relate well to theory was found. In an incipient phase the heat release rate rose with the temperature of the smoke layer/enclosure boundaries. This increase was also found to depend on the flammability properties of the burning object. The results also...

  8. Fire resistant nuclear fuel cask

    International Nuclear Information System (INIS)

    Heckman, R.C.; Moss, M.

    1979-01-01

    The disclosure is directed to a fire resistant nuclear fuel cask employing reversibly thermally expansible bands between adjacent cooling fins such that normal outward flow of heat is not interfered with, but abnormal inward flow of heat is impeded or blocked

  9. Fire resistant PV shingle assembly

    Science.gov (United States)

    Lenox, Carl J.

    2012-10-02

    A fire resistant PV shingle assembly includes a PV assembly, including PV body, a fire shield and a connection member connecting the fire shield below the PV body, and a support and inter-engagement assembly. The support and inter-engagement assembly is mounted to the PV assembly and comprises a vertical support element, supporting the PV assembly above a support surface, an upper interlock element, positioned towards the upper PV edge, and a lower interlock element, positioned towards the lower PV edge. The upper interlock element of one PV shingle assembly is inter-engageable with the lower interlock element of an adjacent PV shingle assembly. In some embodiments the PV shingle assembly may comprise a ventilation path below the PV body. The PV body may be slidably mounted to the connection member to facilitate removal of the PV body.

  10. Fire resistance of prefabricated monolithic slab

    Directory of Open Access Journals (Sweden)

    Gravit Marina

    2017-01-01

    Full Text Available A prefabricated monolithic slab (PMS has a number of valuable advantages, they allow to significantly decrease the weight of construction keeping the necessary structural-load capacity, to speed up and cheapen work conduction, to increase the heat isolating properties of an enclosure structure [1]. In order to create a design method of prefabricated monolithic slab fire-resistance, it's necessary to perform a series of PMS testing, one of which is being described in this article. Subjected to the test is a fragment of prefabricated monolithic slab with polystyrene concrete inserts along the beams with bent metal profile 250 mm thick, with a 2.7 m span loaded with evenly spread load equal to 600 kg/m2. After 3 hour testing for fire-resistance [2] no signs of construction ultimate behavior were detected.

  11. Fire resistance of extruded hollow-core slabs

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl; Sørensen, Lars Schiøtt; Giuliani, Luisa

    2017-01-01

    to the structural codes with data derived from a standard fire test and from a thorough examination of the comprehensive test documentation available on fire exposed hollow-core slabs. Findings – Mechanisms for loss of load-bearing capacity are clarified, and evidence of the fire resistance is found. Originality......Purpose – Prefabricated extruded hollow-core slabs are preferred building components for floor structures in several countries. It is therefore important to be able to document the fire resistance of these slabs proving fulfilment of standard fire resistance requirements of 60 and 120 min found...... in most national building regulations. The paper aims to present a detailed analysis of the mechanisms responsible for the loss of loadbearing capacity of hollow-core slabs when exposed to fire. Design/methodology/approach – Furthermore, it compares theoretica calculation and assessment according...

  12. Designing fire safe interiors.

    Science.gov (United States)

    Belles, D W

    1992-01-01

    Any product that causes a fire to grow large is deficient in fire safety performance. A large fire in any building represents a serious hazard. Multiple-death fires almost always are linked to fires that grow quickly to a large size. Interior finishes have large, continuous surfaces over which fire can spread. They are regulated to slow initial fire growth, and must be qualified for use on the basis of fire tests. To obtain meaningful results, specimens must be representative of actual installation. Variables--such as the substrate, the adhesive, and product thickness and density--can affect product performance. The tunnel test may not adequately evaluate some products, such as foam plastics or textile wall coverings, thermoplastic materials, or materials of minimal mass. Where questions exist, products should be evaluated on a full-scale basis. Curtains and draperies are examples of products that ignite easily and spread flames readily. The present method for testing curtains and draperies evaluates one fabric at a time. Although a fabric tested alone may perform well, fabrics that meet test standards individually sometimes perform poorly when tested in combination. Contents and furnishings constitute the major fuels in many fires. Contents may involve paper products and other lightweight materials that are easily ignited and capable of fast fire growth. Similarly, a small source may ignite many items of furniture that are capable of sustained fire growth. Upholstered furniture can reach peak burning rates in less than 5 minutes. Furnishings have been associated with many multiple-death fires.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Fire resistant aircraft seat program

    Science.gov (United States)

    Fewell, L. A.

    1979-01-01

    Foams, textiles, and thermoformable plastics were tested to determine which materials were fire retardant, and safe for aircraft passenger seats. Seat components investigated were the decorative fabric cover, slip covers, fire blocking layer, cushion reinforcement, and the cushioning layer.

  14. Probability based high temperature engineering creep and structural fire resistance

    CERN Document Server

    Razdolsky, Leo

    2017-01-01

    This volume on structural fire resistance is for aerospace, structural, and fire prevention engineers; architects, and educators. It bridges the gap between prescriptive- and performance-based methods and simplifies very complex and comprehensive computer analyses to the point that the structural fire resistance and high temperature creep deformations will have a simple, approximate analytical expression that can be used in structural analysis and design. The book emphasizes methods of the theory of engineering creep (stress-strain diagrams) and mathematical operations quite distinct from those of solid mechanics absent high-temperature creep deformations, in particular the classical theory of elasticity and structural engineering. Dr. Razdolsky’s previous books focused on methods of computing the ultimate structural design load to the different fire scenarios. The current work is devoted to the computing of the estimated ultimate resistance of the structure taking into account the effect of high temperatur...

  15. Parametric Fires for Structural Design

    DEFF Research Database (Denmark)

    Hertz, Kristian

    2012-01-01

    The authorities, the construction association, and a number of companies in Denmark have supported the author writing a guide for design of building structures for parametric fires. The guide is published by the ministry as a supplement to the building regulations. However, consultants and contra......The authorities, the construction association, and a number of companies in Denmark have supported the author writing a guide for design of building structures for parametric fires. The guide is published by the ministry as a supplement to the building regulations. However, consultants...... and contractors have asked for a reference in English in order to make the guide-lines and the background for them available internationally. The paper therefore presents recommendations from the design guide especially concerning how to assess parametric design fires based on the opening factor method for large...... compartments. Findings leading to the guide-lines are discussed, and it is indicated what a safe design fire model means for structural design and how it differs from a safe design fire model for evacuation. Furthermore, the paper includes some experiences from the application of the design guide in practise...

  16. Fire resistance of slim floor beams

    NARCIS (Netherlands)

    Fellinger, J.H.H.; Twilt, L.

    1996-01-01

    Slim floor beams support decks on a wide plate welded on the lower flange of an 1- shaped beam. The air gap between the plate and the lower flange increases the fire resistance of the beam. A Finite Element Method (FEM) model, validated with three fire tests, is used to set up simple calculation

  17. The importance of verifiable fire protection design

    Energy Technology Data Exchange (ETDEWEB)

    Medonos, Sava [Petrellus Ltd. (United Kingdom)]. E-mail: smm@petrellus.co.uk; Geddes, Paul [Global Solutions UK Ltd. (United Kingdom)]. E-mail: paul@globalsolutionsuk.com

    2004-07-01

    Simplistic methods based on the Hp/A ratio between the heated surface area and volume or a 2-dimensional analysis may be sufficient for the determination of fire protection coatings for simple components. For the optimization of fire protection of pressure systems and load bearing structures, however, they have proved to be inadequate, as they do not represent the response taking place. This often leads to over-protection or inadequate fire resistance. In the past 10 years there have been claims in petrochemical industry of 'methods' for fire protection 'optimization' based on a walk-down through a topside or plant, or a heat-up calculation of a few cross sections with no regard to stress. These methods are wrong. In the best case these 'methods of optimization' lead to high unnecessary costs and in the worst case in an explosion of a vessel, structural collapse, domino effects and cataclysmic fire throughout the plant. The operator or design contractor should always require a Method Statement including a proof of verification to obtain the adequate quality of fire protection. (author)

  18. Manufacturing of Fire Resistance Geopolymer: A Review

    Directory of Open Access Journals (Sweden)

    Aziz Ikmal Hakem

    2016-01-01

    Full Text Available Protection against fire using inorganic polymer is a new application of engineering technology. Even though, there are varieties of fire-protection materials, there is always a need for the development of new materials with improved thermophysical properties and low cost. Geopolymer composites materials are promising from this point of view. Granulated blast furnace slag, boiler ash and fly ash have been used as the prime materials for forming geopolymers composites. Geopolymers have been studied due to its unique properties such as a good fire resistance. Geopolymer offers an innovative for application associated with the high thermal application. This paper summarizes on the potential of alkaliactivated materials over the past decades along with outlines of the manufacturing of geopolymer composites for fire resistance application.

  19. Fire resistance in American heavy timber construction history and preservation

    CERN Document Server

    Heitz, Jesse

    2016-01-01

    This volume presents a history of heavy timber construction (HTC) in the United States, chronicling nearly two centuries of building history, from inception to a detailed evaluation of one of the best surviving examples of the type, with an emphasis on fire resistance. The book does not limit itself in scope to serving only as a common history. Rather, it provides critical analysis of HTC in terms of construction methods, design, technical specifications, and historical performance under fire conditions. As such, this book provides readers with a truly comprehensive understanding and exploration of heavy timber construction in the United States and its performance under fire conditions.

  20. Fire resistance of single pitched-roof steel portal frame

    Directory of Open Access Journals (Sweden)

    J. J. Ferrán Gozálvez

    2017-03-01

    Full Text Available The standard procedure of structural fire design is based on the simplified analysis of single members. This method leads to conservative results in the case of structures able to redistribution of forces. The failure mechanism affecting both life safety and fire propagation is unknown. This work proposes a methodology for the advanced fire calculation of single pitched-roof portal frame for an agroindustrial building according to the Spanish Specifications with the structural software SAP2000. A non-linear dynamic and plastic, geometric (P-Delta and large-displacements calculation method has been developed. The different failure mechanisms and their influence are studied in terms of fire time resistance, human hazard and good safety. Also, parametric analyses were conducted: load level, rotational stiffness of the base and finally, support fire protection.

  1. Fire Resistance Tests of Various Fire Protective Coatings

    Directory of Open Access Journals (Sweden)

    Mindaugas GRIGONIS

    2011-03-01

    Full Text Available Tests were carried out on more than 14 different samples of fire protective coatings in order to investigate a relation between the thickness of the intumescent fire protection coating and the time of exposure to heat. A number of coatings of different chemical composition enabled to determine the fire resistance behaviour patterns. During test the one-side and volumetric methods were employed in observance of the standard temperature-time curves. For one-side method, the coating was applied on one side and all edges of the specimen, whereas for volumetric test the specimens were completely covered with fire protective coating. It is shown that a layer of coating protects the specimen's surface from heat exposure for a certain period of time until full oxidation of the coating occurs. The efficiency of fire protective coatings also depends on thickness of the charred layer of the side exposed to heat.http://dx.doi.org/10.5755/j01.ms.17.1.257

  2. Fire resistant aircraft seat materials

    Science.gov (United States)

    Trabold, E. L.

    1978-01-01

    The establishment of a technical data base for individual seat materials in order to facilitate materials selections is reviewed. The thermal response of multi-layer constructions representative of the basic functional layers of a typical future seat is examined. These functional layers include: (1) decorative fabric cover; (2) slip sheet (topper); (3) fire blocking layer; (4) cushion reinforcement; and (5) cushioning layer. The implications for material selection for full-scale seats are discussed.

  3. Methodology for fire PSA during design process

    International Nuclear Information System (INIS)

    Kollasko, Heiko; Blombach, Joerg

    2009-01-01

    Fire PSA is an essential part of a full scope level 1 PSA. Cable fires play an important role in fire PSA. Usually, cable routing is therefore modeled in detail. During the design of new nuclear power plants the information on cable routing is not yet available. However, for the use of probabilistic safety insights during the design and for licensing purposes a fire PSA may be requested. Therefore a methodology has been developed which makes use of the strictly divisional separation of redundancies in the design of modern nuclear power plants: cable routing is not needed within one division but replaced by the conservative assumption that all equipment fails due to a fire in the concerned division; critical fire areas are defined where components belonging to different divisions may be affected by a fire. For the determination of fire frequencies a component based approach is proposed. The resulting core damage frequencies due to fire are conservative. (orig.)

  4. Fire Resistant Panels for the Tunnel Linings

    Directory of Open Access Journals (Sweden)

    Gravit Marina

    2016-01-01

    Full Text Available Presents the results of studies of innovative materials in the field of experimental and theoretical research fire resistance fireproof panels Pyro-Safe Aestuver T. Owing to the assembly simplicity, materials cheapness, high ecological standard, recycling, reuse potential, are benefit. Research work is running to improve the knowledge about fireproof panels Pyro-Safe Aestuver T for tunnel lining, its basic performance, its long term behavior and in particular also its fire proof for example when used for the lining of road tunnels.

  5. Development of assembly techniques for fire resistant aircraft interior panels

    Science.gov (United States)

    Lee, S. C. S.

    1978-01-01

    Ten NASA Type A fire resistant aircraft interior panels were fabricated and tested to develop assembly techniques. These techiques were used in the construction of a full scale lavatory test structure for flame propagation testing. The Type A panel is of sandwich construction consisting of Nomex honeycomb filled with quinone dioxime foam, and bismaleimide/glass face sheets bonded to the core with polyimide film adhesive. The materials selected and the assembly techniques developed for the lavatory test structure were designed for obtaining maximum fire containment with minimum smoke and toxic emission.

  6. Fire resistance of wood members with directly applied protection

    Science.gov (United States)

    Robert H. White

    2009-01-01

    Fire-resistive wood construction is achieved either by having the structural elements be part of fire-rated assemblies or by using elements of sufficient size that the elements themselves have the required fire-resistance ratings. For exposed structural wood elements, the ratings in the United States are calculated using either the T.T. Lie method or the National...

  7. A new design method for industrial portal frames in fire

    OpenAIRE

    Song, YY; Huang, Z; Burgess, IW; Plank, RJ

    2009-01-01

    For single-storey steel portal frames in fire, especially when they are situated close to a site perimeter, it is imperative that the boundary walls stay close to vertical, so that fires which occur are not allowed to spread to adjacent properties. A current UK fire design guide requires either that the whole frame be protected as a single element, or that the rafter may be left unprotected if column bases and foundations are designed to resist the forces and moments generated by rafter colla...

  8. Materials for fire resistant passenger seats in aircraft

    Science.gov (United States)

    Tesoro, G.; Moussa, A.

    1980-01-01

    The paper considers the selection of cushioning foam and upholstery fabric materials for aircraft passenger seats. Polyurethane, polychloroprene, polyimide, and polyphosphazene are the foam materials considered; and a variety of commercial and developmental fabrics (including wool, cotton, synthetics, and blends) are examined. Viable approaches to the design of fire-resistant seat assemblies are indicated. Results of an experimental laboratory study of fabrics and fabric/foam assemblies exposed to external point-source radiative heat flux are discussed.

  9. DOE Standard: Fire protection design criteria

    International Nuclear Information System (INIS)

    1999-07-01

    The development of this Standard reflects the fact that national consensus standards and other design criteria do not comprehensively or, in some cases, adequately address fire protection issues at DOE facilities. This Standard provides supplemental fire protection guidance applicable to the design and construction of DOE facilities and site features (such as water distribution systems) that are also provided for fire protection. It is intended to be used in conjunction with the applicable building code, National Fire Protection Association (NFPA) Codes and Standards, and any other applicable DOE construction criteria. This Standard replaces certain mandatory fire protection requirements that were formerly in DOE 5480.7A, ''Fire Protection'', and DOE 6430.1A, ''General Design Criteria''. It also contains the fire protection guidelines from two (now canceled) draft standards: ''Glove Box Fire Protection'' and ''Filter Plenum Fire Protection''. (Note: This Standard does not supersede the requirements of DOE 5480.7A and DOE 6430.1A where these DOE Orders are currently applicable under existing contracts.) This Standard, along with the criteria delineated in Section 3, constitutes the basic criteria for satisfying DOE fire and life safety objectives for the design and construction or renovation of DOE facilities

  10. Fire Safety Design of Wood Structures

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl

    2006-01-01

    Lecture Notes on Fire Safety Design of Wood Structures including charring of wood and load bearing capacity of beams, columns, and connections.......Lecture Notes on Fire Safety Design of Wood Structures including charring of wood and load bearing capacity of beams, columns, and connections....

  11. Fire resistant films for aircraft applications

    Science.gov (United States)

    Kourtides, D. A.

    1983-01-01

    Alternative sandwich panel decorative films were investigated as replacements for the polyvinyl fluoride currently used in aircraft interiors. Candidate films were studied for flammability, smoke emission, toxic gas emission, flame spread, and suitability as a printing surface for the decorative acrylic ink system. Several of the candidate films tested were flame modified polyvinyl fluoride, polyvinylidene fluoride, polyimide, polyamide, polysulfone, polyphenylsulfone, polyethersulfone, polybenzimidazole, polycarbonate, polyparabanic acid, polyphosphazene, polyetheretherketon, and polyester. The films were evaluated as pure films only, films silk-screened with an acrylic ink, and films adhered to a phenolic fiberglass substrate. Films which exhibited the highest fire resistant properties included PEEK polyetheretherketon, Aramid polyamide, and ISO-BPE polyester.

  12. Structural fire resistance experimental research priority needs of U.S. industry

    CERN Document Server

    Almand, Kathleen H

    2012-01-01

    Structural Fire Resistance Experimental Research – Priority Needs of U.S. Industry provides a synthesis of stakeholder input to a prioritized agenda for research at the National Fire Research Laboratory (NFRL) at the National Institute of Standards and Technology (NIST) designed to accelerate the implementation of performance-based fire engineering for structures. The NFRL presents a broad range of unanswered questions regarding the performance of real structures in fire conditions, and informs performance-based design methods and standards in this field. The authors conducted a comprehensive literature review of large-scale structural fire testing and compiled research needs from a variety of sources. The book addresses major issues of broad concern in the fire community, such as real fire exposure and structural response, composite floor system performance, enhancing modeling performance, and understanding the embedded safety features in design methods. It concludes with a prioritized set of research reco...

  13. Post-earthquake fire resistance of steel buildings

    DEFF Research Database (Denmark)

    Jelinek, T.; Zania, V.; Giuliani, Luisa

    2017-01-01

    -resistant steel frame to post-earthquake fires (PEFs) is investigated and compared with the response of the undamaged frame exposed to fire only, by means of numerical analyses performed using a commercial finite element software. The frame considered as a case study is not insulated against fire...

  14. Fire resistance of extruded hollow-core slabs

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl; Giuliani, Luisa; Sørensen, Lars Schiøtt

    2016-01-01

    Prefabricated extruded hollow-core slabs are preferred building components for floor structures in several countries. It is therefore important to be able to document the fire resistance of these slabs proving fulfilment of standard fire resistance requirements of 60- and 120 minutes found in most...... a standard fire test and from a thorough examination of the comprehensive test documentation available on fire exposed hollow-core slabs. Mechanisms for loss of load-bearing capacity are clarified, and evidence of the fire resistance is found. For the first time the mechanisms responsible for loss of load......-bearing capacity are identified and test results and calculation approach are for the first time Applied in accordance with each other for assessment of fire resistance of the structure....

  15. Different design approaches to structural fire safety

    DEFF Research Database (Denmark)

    Giuliani, Luisa; Budny, I.

    2013-01-01

    -priori evaluate which design is the safest or the most economical one: a punctual analysis of the different aspects and a comparison of the resulting designs is therefore of interest and is presented in this paper with reference to the case study considered.The third approach refers instead to a performance......-based fire design of the structure(PBFD), where safety goals are explicitly defined and a deeper knowledge of the structural response to fire effects can be achieved, for example with the avail of finite element analyses (FEA). On the other hand, designers can’t follow established procedures when undertaking...... such advanced investigations, which are generally quite complex ones, due to the presence of material degradation and large displacements induced by fire, as well as the possible triggering of local mechanism in the system. An example of advanced investigations for fire design is given in the paper...

  16. 30 CFR 77.1913 - Fire-resistant wood.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  17. Sodium Fire Demonstration Facility Design and Operation

    International Nuclear Information System (INIS)

    Cho, Youngil; Kim, Jong-Man; Lee, Jewhan; Hong, Jonggan; Yeom, Sujin; Cho, Chungho; Jung, Min-Hwan; Gam, Da-Young; Jeong, Ji-Young

    2014-01-01

    Although sodium has good characteristics such as high heat transfer rate and stable nuclear property, it is difficult to manage because of high reactivity. Sodium is solid at the room temperature and it easily reacts with oxygen resulting in fire due to the reaction heat. Thus, sodium must be stored in a chemically stable place, i.e., an inert gas-sealed or oil filled vessel. When a sodium fire occurs, the Na 2 O of white fume is formed. It is mainly composed of Na 2 O 2 , NaOH, and Na 2 CO 3 , ranging from 0.1 to several tens of micrometers in size. It is known that the particle size increases by aggregation during floating in air. Thus, the protection method is important and should be considered in the design and operation of a sodium system. In this paper, sodium fire characteristics are described, and the demonstration utility of outbreak of sodium fire and its extinguishing is introduced. In this paper, sodium fire characteristics and a demonstration facility are described. The introduced sodium fire demonstration facility is the only training device used to observe a sodium fire and extinguish it domestically. Furthermore, the type of sodium fire will be diversified with the enhancement of the utility. It is expected that this utility will contribute to experience in the safe treatment of sodium by the handlers

  18. INVESTIGATION OF THERMAL BEHAVIOR OF MULTILAYERED FIRE RESISTANT STRUCTURE

    Directory of Open Access Journals (Sweden)

    R. GUOBYS

    2016-09-01

    Full Text Available This paper presents experimental and numerical investigations of thermal behavior under real fire conditions of new generation multilayered fire resistant structure (fire door, dimensions H × W × D: 2090 × 980 × 52 mm combining high strength and fire safety. This fire door consists of two steel sheets (thickness 1.5 and 0.7 mm with stone wool ( = 33 kg/m3, k = 0.037 W/mK, E = 5000 N/m2,  = 0.2 insulating layer in between. One surface of the structure was heated in fire furnace for specified period of time of 60 min. Temperature and deformation of opposite surface were measured from outside at selected measuring points during fire resistance test. Results are presented as temperature-time and thermal deformation-time graphs. Experimental results were compared with numerical temperature field simulation results obtained from SolidWorks®Simulation software. Numerical results were found to be in good agreement with experimental data. The percent differences between door temperatures from simulation and fire resistance test don’t exceed 8%. This shows that thermal behaviour of such multilayered structures can be investigated numerically, thus avoiding costly and time-consuming fire resistance tests. It is established that investigated structure should be installed in a way that places thicker steel sheet closer to the potential heat source than thinner one. It is also obtained that stone wool layer of higher density should be used to improve fire resistance of the structure.

  19. Evidence of fire resistance of hollow-core slabs

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl; Sørensen, Lars Schiøtt; Giuliani, Luisa

    is therefore going on in the Netherlands about the fire resistance of hollow-core slabs. In 2014 the producers of hollow-core slabs have published a report of a project called Holcofire containing a collection of 162 fire tests on hollow-core slabs giving for the first time an overview of the fire tests made....... The present paper analyses the evidence now available for assessment of the fire resistance of extruded hollow-core slabs. The 162 fire tests from the Holcofire report are compared against the requirements for testing from the product standard for hollow-core slabs EN1168 and knowledge about the possible......Hollow-core slabs have during the past 50 years comprised a variety of different structures with different cross-sections and reinforcement. At present the extruded hollow-core slabs without cross-reinforcement in the bottom flange and usually round or oval longitudinal channels (holes...

  20. An Expert System for Designing Fire Prescriptions

    Science.gov (United States)

    Elizabeth Reinhardt

    1987-01-01

    Managers use prescribed fire to accomplish a variety of resource objectives. The knowledge needed to design successful prescriptions is both quantitative and qualitative. Some of it is available through publications and computer programs, but much of the knowledge of expert practitioners has never been collected or published. An expert system being developed at the,...

  1. FIRE

    International Nuclear Information System (INIS)

    Brtis, J.S.; Hausheer, T.G.

    1990-01-01

    FIRE, a microcomputer based program to assist engineers in reviewing and documenting the fire protection impact of design changes has been developed. Acting as an electronic consultant, FIRE is designed to work with an experienced nuclear system engineer, who may not have any detailed fire protection expertise. FIRE helps the engineer to decide if a modification might adversely affect the fire protection design of the station. Since its first development, FIRE has been customized to reflect the fire protection philosophy of the Commonwealth Edison Company. That program is in early production use. This paper discusses the FIRE program in light of its being a useful application of expert system technologies in the power industry

  2. Evaluating a protocol for testing fire-resistant oil-spill containment boom

    International Nuclear Information System (INIS)

    Walton, W.D.; Twilley, W.H.; Hiltabrand, R.R.; Mullin, J.V.

    1998-01-01

    A series of experiments were conducted to evaluate a protocol for testing the ability of fire-resistant booms to withstand both fire and waves. Most response plans for in situ burning of oil at sea require the use of a fire-resistant boom to contain the oil during a burn. For this study, a wave tank was designed and constructed to assess the capabilities of a 15 m section of a boom subjected to a 5 m diameter fire with 0.15 m high waves. Five typical fire-resistant oil-spill containment booms were tested. The purpose of the project was to evaluate the test procedure, therefore the overall performance of the boom was not evaluated on a pass-fail criterion. The two most important aspects of the test method were repeatability and reproducibility. Some of the parameters tested included the effect of wind, waves, fire size, and fire duration. Methods to constrain the booms were also tested. 7 refs., 6 tabs., 7 figs

  3. Fire Extinguisher Training for Fire Watch and Designated Workers, Course 9893

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Jimmy D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-04-19

    At Los Alamos National Laboratory (LANL), all workers must be aware of LANL fire protection policies and be trained on what to do in the event of a fire. This course, Fire Extinguisher Training for Fire Watch and Designated Workers (#9893), provides awareness-level and hands-on training for fire watch personnel and designated workers. Fire watch personnel and designated workers are appointed by line management and must receive both awareness-level training and hands-on training in the use of portable fire extinguishers to extinguish an incipient-stage fire. This training meets the requirements of the Occupational Safety and Health Administration (OSHA) Code of Federal Regulations (CFR) 29 CFR 1910.157, Portable Fire Extinguishers, and Procedure (P) 101-26, Welding, Cutting, and Other Spark-/Flame-Producing Operations.

  4. Fire Extinguisher Designated Worker and Fire Watch: Self-Study Course 15672

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Jimmy D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-07-08

    At Los Alamos National Laboratory (LANL), all workers must be aware of LANL fire protection policies and be trained on what to do in the event of a fire. This course, Fire Extinguisher Training for Fire Watch and Designated Workers (#9893), provides awareness-level and hands-on training for fire watch personnel and designated workers. Fire watch personnel and designated workers are appointed by line management and must receive both awareness-level training and hands-on training in the use of portable fire extinguishers to extinguish an incipient-stage fire. This training meets the requirements of the Occupational Safety and Health Administration (OSHA) Code of Federal Regulations (CFR) 29 CFR 1910.157, Portable Fire Extinguishers, and Procedure (P) 101-26, Welding, Cutting, and Other Spark-/Flame-Producing Operations.

  5. Prove of structural fire design in nuclear power plants

    International Nuclear Information System (INIS)

    Schneider, U.; Hosser, D.; Max, U.

    1986-01-01

    Based on the application of comprehensive heat balance calculations the whole parameters like geometry, fire load, ventilation conditions etc. of a German PWR were covered. A practical design procedure based on diagrams was developed whereby separate diagrams for oil and cable fires were presented. A probabilistic safety concept was employed as to account for the specific variations of fire parameters as fire load and area, ventilation condition, rate of burning. With respect to the frequency of fire occurrences and the impact of fire fighting measures on the spread of fires latest statistical data of a special BMI investigation were used. (orig./HP) [de

  6. Safety design guides for fire protection for CANDU 9

    International Nuclear Information System (INIS)

    Lee, Duk Su; Chang, Woo Hyun; Lee, Nam Young; A. C. D. Wright

    1996-03-01

    This safety design guide establishes design requirements to ensure the radiological risk to the public due to fire is acceptable and operating personnel are adequately protected from the hazards of fires. This safety design guide also specifies the safety criteria for fire protection to be applied to mitigate fires and recommends the fire protection program to be established to initiate, coordinate and document the design activities associated with fire protection. The requirements for fire protection outlined in this safety design guide shall be satisfied in the design stage and the change status of the regulatory requirements, code and standards should be traced and incorporated into this safety design guide accordingly. 1 fig., (Author) .new

  7. Improvement of flame resistance of non-flame retardant cables by applying fire protection measures

    International Nuclear Information System (INIS)

    Takemura, Yujiro; Segoshi, Yoshinori; Jinno, Susumu; Mii, Kazuki

    2017-01-01

    The new regulatory requirements, which were put in force after the Fukushima Daiichi accident, impose the use of flame retardant cables on the plant components having safety functions for the purpose of fire protection. However, some Japanese nuclear power plants built in the early days use non-flame retardant cables that do not pass the demonstration test to check for the flame resistance. To cope with the new regulatory requirements, a fire protection measure for non-flame retardant cables was introduced to assure flame resistance of non-flame retardant cables equivalent to or higher than that of flame retardant cables. To illustrate the fire protection measure, both non-flame retardant cables and its cable tray are covered with fire protection sheet fabricated from incombustible material to form an assembly. Considering the demonstration test results, it can be concluded that flame resistance performance of non-flame retardant cables equivalent to or higher than that of flame retardant cables can be assured by forming the assembly even if an external fire outside the assembly and internal cable fire inside the assembly are assumed. This paper introduces the design of the assembly consisting of a bundle of cables and a cable tray and summarizes the results of demonstration tests. (author)

  8. Fire blight resistance in wild accessions of Malus sieversii

    Science.gov (United States)

    Fire blight (Erwinia amylovora) is a devastating bacterial disease in apple that results in severe economic losses. Epidemics are becoming more common as susceptible cultivars and rootstocks are being planted, and control is becoming more difficult as antibiotic-resistant strains develop. Resistan...

  9. Fire and the Design of Educational Buildings. Building Bulletin 7. Sixth Edition.

    Science.gov (United States)

    Department of Education and Science, London (England).

    This bulletin offers guidance on English school premises regulations applying to safety protection against fires in the following general areas: means of escape in case of fire; precautionary measures to prevent fire; fire warning systems and fire fighting; fire spreading speed; structures and materials resistant to fires; and damage control. It…

  10. 76 FR 71831 - Defense Federal Acquisition Regulation Supplement: Fire-Resistant Fiber for Production of...

    Science.gov (United States)

    2011-11-18

    ..., suppliers, or distributors of fire-resistant fibers, yarns, fabrics, or military uniforms) submitted.... The law does not restrict DoD's selection and use of fabrics containing fire-resistant rayon fiber... from selecting fabrics that include fire- resistant rayon fibers. Response: These responses have...

  11. Seismic design criteria of fire protection systems for DOE facilities

    International Nuclear Information System (INIS)

    Hardy, G.; Cushing, R.; Driesen, G.

    1991-01-01

    Fire protection systems are critical to the safety of personnel and to the protection of inventory during any kind of emergency situation that involves a fire. The importance of these fire protection systems is hightened for DOE facilities which often house nuclear, chemical or scientific processes. Current research into the topic of open-quotes fires following earthquakesclose quotes has demonstrated that the risks of a fire starting as a result of a major earthquake can be significant. Thus, fire protection systems need to be designed to withstand the anticipated seismic event for the site in question

  12. Basing of a complex design measures for protection against fire

    International Nuclear Information System (INIS)

    Kryuger, V.

    1983-01-01

    Fire impact on NPP radiation safety is analyzed. The general industry requirements to the protection system against fire are shown to be insufficient for NPPs. A complex of protection measures against fire is suggested that should be taken into account in the NPP designs [ru

  13. The Fire Resistance Performance of Recycled Aggregate Concrete Columns with Different Concrete Compressive Strengths.

    Science.gov (United States)

    Dong, Hongying; Cao, Wanlin; Bian, Jianhui; Zhang, Jianwei

    2014-12-08

    In order to ascertain the fire resistance performance of recycled aggregate concrete (RAC) components with different concrete compressive strengths, four full-scaled concrete columns were designed and tested under high temperature. Two of the four specimens were constructed by normal concrete with compressive strength ratings of C20 and C30, respectively, while the others were made from recycled coarse aggregate (RCA) concrete of C30 and C40, respectively. Identical constant axial forces were applied to specimens while being subjected to simulated building fire conditions in a laboratory furnace. Several parameters from the experimental results were comparatively analyzed, including the temperature change, vertical displacement, lateral deflection, fire endurance, and failure characteristics of specimens. The temperature field of specimens was simulated with ABAQUS Software (ABAQUS Inc., Provindence, RI, USA) and the results agreed quite well with those from the experiments. Results show that the rate of heat transfer from the surface to the interior of the column increases with the increase of the concrete's compressive strength for both RAC columns and normal concrete columns. Under the same initial axial force ratio, for columns with the same cross section, those with lower concrete compressive strengths demonstrate better fire resistance performance. The fire resistance performance of RAC columns is better than that of normal concrete columns, with the same concrete compressive strength.

  14. The Fire Resistance Performance of Recycled Aggregate Concrete Columns with Different Concrete Compressive Strengths

    Science.gov (United States)

    Dong, Hongying; Cao, Wanlin; Bian, Jianhui; Zhang, Jianwei

    2014-01-01

    In order to ascertain the fire resistance performance of recycled aggregate concrete (RAC) components with different concrete compressive strengths, four full-scaled concrete columns were designed and tested under high temperature. Two of the four specimens were constructed by normal concrete with compressive strength ratings of C20 and C30, respectively, while the others were made from recycled coarse aggregate (RCA) concrete of C30 and C40, respectively. Identical constant axial forces were applied to specimens while being subjected to simulated building fire conditions in a laboratory furnace. Several parameters from the experimental results were comparatively analyzed, including the temperature change, vertical displacement, lateral deflection, fire endurance, and failure characteristics of specimens. The temperature field of specimens was simulated with ABAQUS Software (ABAQUS Inc., Provindence, RI, USA) and the results agreed quite well with those from the experiments. Results show that the rate of heat transfer from the surface to the interior of the column increases with the increase of the concrete’s compressive strength for both RAC columns and normal concrete columns. Under the same initial axial force ratio, for columns with the same cross section, those with lower concrete compressive strengths demonstrate better fire resistance performance. The fire resistance performance of RAC columns is better than that of normal concrete columns, with the same concrete compressive strength. PMID:28788279

  15. Fire Resistance of Large-Scale Cross-Laminated Timber Panels

    Science.gov (United States)

    Henek, Vladan; Venkrbec, Václav; Novotný, Miloslav

    2017-12-01

    Wooden structures are increasingly being used in the construction of residential buildings. A common and often published reason to avoid wooden structures is their insufficient fire resistance, which reduces bearing capacity. For this reason, composite sandwich structures began to be designed to eliminate this drawback, as well as others. Recently, however, the trend is for a return to the original, wood-only variant and a search is underway for new technical means of improving the properties of such structures. Many timber structure technologies are known, but structures made from cross-laminated timber (CLT) panels have been used very often in recent years. CLT panels, also known as X-LAM, are currently gaining popularity in Europe. In the case of CLT panels composed of several layers of boards, they can be said to offer a certain advantage in that after the surface layer of a board has burnt and the subsurface layer has dried, oxygen is not drawn to the unburned wood for further combustion and thus the burning process ceases. CLT panels do not need to be specially modified or coated with fire resistant materials, although they are usually lined with gypsum-fibre fire resistant boards due to guidelines set out in the relevant standards. This paper presents a new method for the assessment of load-bearing perimeter walls fabricated from CLT panels without the use of an inner fire-retardant lining to ensure fire resistance at the level required by European standards (i.e. those harmonized for the Czech construction industry). The calculations were verified through laboratory tests which show that better parameters can be achieved during the classification of structures from the fire resistance point of view. The aim of the article is to utilize the results of assessment and testing by an accredited laboratory in order to demonstrate the possibilities of using CLT panels for the construction of multistorey as well as multi-purpose buildings in the Czech Republic.

  16. Numerical prediction of fire resistance of RC beams

    Science.gov (United States)

    Serega, Szymon; Wosatko, Adam

    2018-01-01

    Fire resistance of different structural members is an important issue of their strength and durability. A simple but effective tool to investigate multi-span reinforced concrete beams exposed to fire is discussed in the paper. Assumptions and simplifications of the theory as well as numerical aspects are briefly reviewed. Two steps of nonlinear finite element analysis and two levels of observation are distinguished. The first step is the solution of transient heat transfer problem in representative two-dimensional reinforced concrete cross-section of a beam. The second part is a nonlinear mechanical analysis of the whole beam. All spans are uniformly loaded, but an additional time-dependent thermal load due to fire acts on selected ones. Global changes of curvature and bending moment functions induce deterioration of the stiffness. Benchmarks are shown to confirm the correctness of the model.

  17. Fire resistance properties of ceramic wool fiber reinforced intumescent coatings

    Energy Technology Data Exchange (ETDEWEB)

    Amir, N., E-mail: norlailiamir@petronas.com.my; Othman, W. M. S. W., E-mail: wamosa@gmail.com; Ahmad, F., E-mail: faizahmad@petronas.com.my [Mechanical Engineering Department, Universiti Teknologi PETRONAS Bandar Seri Iskandar, 31750 Tronoh, Perak (Malaysia)

    2015-07-22

    This research studied the effects of varied weight percentage and length of ceramic wool fiber (CWF) reinforcement to fire retardant performance of epoxy-based intumescent coating. Ten formulations were developed using ammonium polyphosphate (APP), expandable graphite (EG), melamine (MEL) and boric acid (BA). The mixing was conducted in two stages; powdered materials were grinded in Rocklabs mortar grinder and epoxy-mixed using Caframo mixer at low speed mixing. The samples were applied on mild steel substrate and exposed to 500°C heat inside Carbolite electric furnace. The char expansion and its physical properties were observed. Scanning electron microscopy (SEM) analyses were conducted to inspect the fiber dispersion, fiber condition and the cell structure of both coatings and chars produced. Thermogravimetric analyses (TGA) were conducted to study the thermal properties of the coating such as degradation temperature and residual weight. Fire retardant performance was determined by measuring backside temperature of substrate in 1-hour, 1000°C Bunsen burner test according to UL 1709 fire regime. The results showed that intumescent coating reinforced with CWF produced better fire resistance performance. When compared to unreinforced coating, formulation S6-15 significantly reduced steel temperature at approximately 34.7% to around 175°C. However, higher fiber weight percentage had slightly decreased fire retardant performance of the coating.

  18. Fire resistance properties of ceramic wool fiber reinforced intumescent coatings

    International Nuclear Information System (INIS)

    Amir, N.; Othman, W. M. S. W.; Ahmad, F.

    2015-01-01

    This research studied the effects of varied weight percentage and length of ceramic wool fiber (CWF) reinforcement to fire retardant performance of epoxy-based intumescent coating. Ten formulations were developed using ammonium polyphosphate (APP), expandable graphite (EG), melamine (MEL) and boric acid (BA). The mixing was conducted in two stages; powdered materials were grinded in Rocklabs mortar grinder and epoxy-mixed using Caframo mixer at low speed mixing. The samples were applied on mild steel substrate and exposed to 500°C heat inside Carbolite electric furnace. The char expansion and its physical properties were observed. Scanning electron microscopy (SEM) analyses were conducted to inspect the fiber dispersion, fiber condition and the cell structure of both coatings and chars produced. Thermogravimetric analyses (TGA) were conducted to study the thermal properties of the coating such as degradation temperature and residual weight. Fire retardant performance was determined by measuring backside temperature of substrate in 1-hour, 1000°C Bunsen burner test according to UL 1709 fire regime. The results showed that intumescent coating reinforced with CWF produced better fire resistance performance. When compared to unreinforced coating, formulation S6-15 significantly reduced steel temperature at approximately 34.7% to around 175°C. However, higher fiber weight percentage had slightly decreased fire retardant performance of the coating

  19. Fire resistance properties of ceramic wool fiber reinforced intumescent coatings

    Science.gov (United States)

    Amir, N.; Othman, W. M. S. W.; Ahmad, F.

    2015-07-01

    This research studied the effects of varied weight percentage and length of ceramic wool fiber (CWF) reinforcement to fire retardant performance of epoxy-based intumescent coating. Ten formulations were developed using ammonium polyphosphate (APP), expandable graphite (EG), melamine (MEL) and boric acid (BA). The mixing was conducted in two stages; powdered materials were grinded in Rocklabs mortar grinder and epoxy-mixed using Caframo mixer at low speed mixing. The samples were applied on mild steel substrate and exposed to 500°C heat inside Carbolite electric furnace. The char expansion and its physical properties were observed. Scanning electron microscopy (SEM) analyses were conducted to inspect the fiber dispersion, fiber condition and the cell structure of both coatings and chars produced. Thermogravimetric analyses (TGA) were conducted to study the thermal properties of the coating such as degradation temperature and residual weight. Fire retardant performance was determined by measuring backside temperature of substrate in 1-hour, 1000°C Bunsen burner test according to UL 1709 fire regime. The results showed that intumescent coating reinforced with CWF produced better fire resistance performance. When compared to unreinforced coating, formulation S6-15 significantly reduced steel temperature at approximately 34.7% to around 175°C. However, higher fiber weight percentage had slightly decreased fire retardant performance of the coating.

  20. Fire-resistant materials for aircraft passenger seat construction

    Science.gov (United States)

    Fewell, L. L.; Tesoro, G. C.; Moussa, A.; Kourtides, D. A.

    1979-01-01

    The thermal response characteristics of fabric and fabric-foam assemblies are described. The various aspects of the ignition behavior of contemporary aircraft passenger seat upholstery fabric materials relative to fabric materials made from thermally stable polymers are evaluated. The role of the polymeric foam backing on the thermal response of the fabric-foam assembly is also ascertained. The optimum utilization of improved fire-resistant fabric and foam materials in the construction of aircraft passenger seats is suggested.

  1. Advanced analysis and design for fire safety of steel structures

    CERN Document Server

    Li, Guoqiang

    2013-01-01

    Advanced Analysis and Design for Fire Safety of Steel Structures systematically presents the latest findings on behaviours of steel structural components in a fire, such as the catenary actions of restrained steel beams, the design methods for restrained steel columns, and the membrane actions of concrete floor slabs with steel decks. Using a systematic description of structural fire safety engineering principles, the authors illustrate the important difference between behaviours of an isolated structural element and the restrained component in a complete structure under fire conditions. The book will be an essential resource for structural engineers who wish to improve their understanding of steel buildings exposed to fires. It is also an ideal textbook for introductory courses in fire safety for master’s degree programs in structural engineering, and is excellent reading material for final-year undergraduate students in civil engineering and fire safety engineering. Furthermore, it successfully bridges th...

  2. Development of fire resistant, nontoxic aircraft interior materials

    Science.gov (United States)

    Haley, G.; Silverman, B.; Tajima, Y.

    1976-01-01

    All available newly developed nonmetallic polymers were examined for possible usage in developing fire resistant, nontoxic nonmetallic parts or assemblies for aircraft interiors. Specifically, feasibility for the development of clear films for new decorative laminates, compression moldings, injection molded parts, thermoformed plastic parts, and flexible foams were given primary considerations. Preliminary data on the flame resistant characteristics of the materials were obtained. Preliminary toxicity data were generated from samples of materials submitted from the contractor. Preliminary data on the physical characteristics of various thermoplastic materials to be considered for either compression molded, injection molded, or thermoformed parts were obtained.

  3. Fatigue Characterization of Fire Resistant Syntactic Foam Core Material

    Science.gov (United States)

    Hossain, Mohammad Mynul

    Eco-Core is a fire resistant material for sandwich structural application; it was developed at NC A&T State University. The Eco-Core is made of very small amount of phenolic resin and large volume of flyash by a syntactic process. The process development, static mechanical and fracture, fire and toxicity safety and water absorption properties and the design of sandwich structural panels with Eco-Core material was established and published in the literature. One of the important properties that is needed for application in transportation vehicles is the fatigue performance under different stress states. Fatigue data are not available even for general syntactic foams. The objective of this research is to investigate the fatigue performance of Eco-Core under three types of stress states, namely, cyclic compression, shear and flexure, then document failure modes, and develop empherical equations for predicting fatigue life of Eco-Core under three stress states. Compression-Compression fatigue was performed directly on Eco-Core cylindrical specimen, whereas shear and flexure fatigue tests were performed using sandwich beam made of E glass-Vinyl Ester face sheet and Eco-Core material. Compression-compression fatigue test study was conducted at two values of stress ratios (R=10 and 5), for the maximum compression stress (sigmamin) range of 60% to 90% of compression strength (sigmac = 19.6 +/- 0.25 MPa) for R=10 and 95% to 80% of compression strength for R=5. The failure modes were characterized by the material compliance change: On-set (2% compliance change), propagation (5%) and ultimate failure (7%). The number of load cycles correspond to each of these three damages were characterized as on-set, propagation and total lives. A similar approach was used in shear and flexure fatigue tests with stress ratio of R=0.1. The fatigue stress-number of load cycles data followed the standard power law equation for all three stress states. The constant of the equation were

  4. An evaluation of propane as a fuel for testing fire-resistant oil spill containment booms

    International Nuclear Information System (INIS)

    Walton, W. D.; Twilley, W. H.

    1997-01-01

    A series of experiments have been conducted to measure and compare the thermal exposure to a fire-resistant boom from liquid hydrocarbon fuel and propane fires. The objective was to test the potential of propane fueled fires as a fire source for testing fire-resistant oil spill containment booms.Thermal exposure from propane fires have been measured with and without waves. Results indicated that although propane diffusion flames on water look like liquid hydrocarbon fuel flames and produce very little smoke, the heat flux at the boom location from propane fires is about 60 per cent of that from liquid hydrocarbon fuel fires. Despite the attractive features in terms of ease of application, control and smoke emissions, it was concluded that the low heat flux would preclude the application of propane as a fuel for evaluating fire resistant containment booms. 2 refs., 7 figs

  5. Fire resistance of a steel plate reinforced concrete bearing wall

    International Nuclear Information System (INIS)

    Kodaira, Akio; Kanchi, Masaki; Fujinaka, Hideo; Akita, Shodo; Ozaki, Masahiko

    2003-01-01

    Samples from a steel plate reinforced concrete bearing wall composed of concrete slab sandwiched between studded steel plates, were subjected to loaded fire resistance tests. There were two types of specimens: some were 1800 mm high while the rest were 3000 mm high ; thickness and width were the same for all specimens, at 200 mm and 800 mm, respectively. Under constant load conditions, one side of each specimen was heated along the standard fire-temperature curve. The results enabled us to approximate the relationship between the ratio of working load to concrete strength N/(Ac x c σ b) and the fire resistance time (t: minutes), as equation (1) for the 1800 mm - high specimen, and equation (2) for the 3000 mm - high specimen. N/(Ac x c σ b) = 2.21 x (1/t) 0.323 (1), .N/(Ac x c σ b) 2.30 x (1/t) 0.378 (2) In addition, the temperature of the unheated side of the specimens was 100degC at 240 minutes of continuous heating, clearly indicating that there was sufficient heat insulation. (author)

  6. The Fire Resistance Performance of Recycled Aggregate Concrete Columns with Different Concrete Compressive Strengths

    OpenAIRE

    Dong, Hongying; Cao, Wanlin; Bian, Jianhui; Zhang, Jianwei

    2014-01-01

    In order to ascertain the fire resistance performance of recycled aggregate concrete (RAC) components with different concrete compressive strengths, four full-scaled concrete columns were designed and tested under high temperature. Two of the four specimens were constructed by normal concrete with compressive strength ratings of C20 and C30, respectively, while the others were made from recycled coarse aggregate (RCA) concrete of C30 and C40, respectively. Identical constant axial forces were...

  7. Design criteria document, Fire Protection Task, K Basin Essential Systems Recovery, Project W-405

    International Nuclear Information System (INIS)

    Johnson, B.H.

    1994-01-01

    The K Basin were constructed in the early 1950's with a 20 year design life. The K Basins are currently in their third design life and are serving as a near term storage facility for irradiated N Reactor fuel until an interim fuel storage solution can be implemented. In April 1994, Project W-405, K Basin Essential Systems Recovery, was established to address (among other things) the immediate fire protection needs of the 100K Area. A Fire Barrier Evaluation was performed for the wall between the active and inactive areas of the 105KE and 105KW buildings. This evaluation concludes that the wall is capable of being upgraded to provide an equivalent level of fire resistance as a qualified barrier having a fire resistance rating of 2 hours. The Fire Protection Task is one of four separate Tasks included within the scope of Project W405, K Basin Essential systems Recovery. The other three Tasks are the Water Distribution System Task, the Electrical System Task, and the Maintenance Shop/Support Facility Task. The purpose of Project W-405's Fire Protection Task is to correct Life Safety Code (NFPA 101) non-compliances and to provide fire protection features in Buildings 105KE, 105KW and 190KE that are essential for assuring the safe operation and storage of spent nuclear fuel at the 100K Area Facilities' Irradiated Fuel Storage Basins (K Basins)

  8. Fire behavior sensor package remote trigger design

    Science.gov (United States)

    Dan Jimenez; Jason Forthofer; James Reardon; Bret Butler

    2007-01-01

    Fire behavior characteristics (such as temperature, radiant and total heat flux, 2- and 3-dimensional velocities, and air flow) are extremely difficult to measure insitu. Although insitu sensor packages are capable of such measurements in realtime, it is also essential to acquire video documentation as a means of better understanding the fire behavior data recorded by...

  9. Design guide for fire protection of grouped electrical cables

    International Nuclear Information System (INIS)

    Dungan, K.W.

    1991-05-01

    This paper develops design guidance for fire protection of grouped electrical cables using previous research and the concept of design objectives based on damage limits. A quantitative approach is taken to establishing performance-oriented design objectives and addressing fires exposing cables as well as cable fires. A one-page Design Calculation Checklist is developed and examples are shown. In addition, testing was done for placement of linear thermal detection on cable trays and recommendations are given. 32 refs., 10 figs., 8 tabs

  10. Influence of expandable graphite on fire resistance and water resistance of flame-retardant coatings

    International Nuclear Information System (INIS)

    Wang, Zhenyu; Han, Enhou; Ke, Wei

    2007-01-01

    Expandable graphite (EG) coating and ammonium polyphosphate-pentaerythritol-melamine (APP-PER-MEL) coating were prepared. Thermal degradation and char formation of the coatings were investigated by differential thermal analysis (DTA), thermogravimetry (TG), X-ray diffraction (XRD), scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The results have shown that the anti-oxidation and fire-resistant properties of expandable graphite coating containing EG with size of 74 μm are better than those of APP-PER-MEL coating. The static immersion test was applied to study water resistance of the coatings, and the fire protection test and mechanical test were used to analyse heat insulation and mechanical properties of coatings before and after water immersion. The fire-resistant and mechanical properties of APP-PER-MEL coating were severely damaged by water immersion, whereas EG coating containing 8.5% EG with size of 74 μm could retain the good fire resistance even after 500 h water immersion

  11. Development of new radiation resistant, fire-retardant cables

    International Nuclear Information System (INIS)

    Hagiwara, Ko; Morita, Yosuke; Udagawa, Takashi; Fujimura, Shun-ichi; Oda, Eisuke.

    1982-01-01

    For the cables for nuclear facilities, radiation resistance and fire-retardation are severely required. The authors took note of the fact that even in the existing cables for nuclear power plants, their mechanical properties are greatly degraded by the exposure to large dose (for example, 200 Mrad in PWR testing conditions), and attempted the improvement. They employed a new additive, bromated acenaphthylene condensate (con-BACN), which effectively gives radiation resistance and also is a good flame retarder, to be compounded to an insulation material, and examined the characteristics. In this paper, the features of con-BACN and the investigation of fire-retardant EPDM composition are described. As an initial composition, a small amount of zinc white, sulphur, stearic acid, noclac 224 (Ouchi-Shinko Chemicals, Co.), and antimony trioxide, 100 parts of tale and 45 parts of con-BACN were added to 100 parts of EPDM (propylene content 34 %, Japan Synthetic Rubber Co.). As the antiaging agent, it was decided to use phenol series No. 3 as a result of test. The fire-retardant EP rubber-composed cable was produced for trial, its insulation being fabricated, using a Furukawa's pressurized salt bath continuous vulcanizer. The tests of γ-irradiation, simulated LOCA and combustion were carried out, and the test results are reported. It was indicated that the cable resisted against high dose several times as much as 200 Mrad, and was suitable for the applications, in which the mechanical properties such as bending are required to be maintained after radiation exposure. It was also found that con-BACN was safe, and its properties of decomposition, concentration and acute toxicity were all very low. (Wakatsuki, Y.)

  12. Maleimido substituted cyclotriphosphazene resins for fire and heat resistant composites

    Science.gov (United States)

    Kumar, D.; Fohlen, G. M.; Parker, J. A.

    1983-01-01

    A new class of fire- and heat-resistant matrix resins have been synthesized by the thermal polymerization of maleimido substituted phenoxycyclotriphosphazenes. The resins have exhibited a char yield of 82 percent at 800 C in nitrogen and 81 percent at 700 C in air. Graphite-fabric laminates based on a resin of this class have shown a limiting oxygen index of 100 percent even at 300 C. Details of the fabrication of the resins and the composites and testing procedures are discussed.

  13. Thermal Radiation for Structural Fire Safety Design

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl

    2006-01-01

    The lecture notes give a short introduction of the theory of thermal radiation. The most elementary concepts and methods are presented in order to give a fundamental knowledge for calculation of the load bearing capacities of fire exposed building constructions....

  14. Design and Construction of Oil Fired Compact Crucible Furnace ...

    African Journals Online (AJOL)

    As a prelude to necessary industrialization, foundries are springing up in various parts of Nigeria and most of these foundries rely on oil fired furnaces in their operation. This study is aimed at developing an oil fired crucible furnace from locally sourced materials for foundries in Nigeria. In our design, a new system of fuel ...

  15. Testing fire resistant boom in waves and flames

    International Nuclear Information System (INIS)

    McCourt, J.; Buist, I.; Pratte, B.; Jamieson, W.; Mullin, J.

    1997-01-01

    A near full-scale screening test to evaluate the durability and ability of refractory-fabric fire resistant booms to contain oil during an in-situ burn without the environmental problems of burning crude oil or the cost of testing offshore, was developed. The boom was first flexed under tension for two hours, then deployed in a U-configuration in an outdoor wave tank. Propane gas was burned in the pocket of the boom to simulate the collection and burning phases of an in-situ burn. Finally, the boom was returned to the indoor wave flume for another two hours of wave action and then inspected for damage. Results indicated damage of the same type as suffered in previously conducted sea trials, although the extent of damage was less severe. These results led to recommendations for improvement of the test protocol which included: (1) increasing the heat flux to the boom, (2) improving the heat flux measurement, (3) increasing the tension in the fire boom during flame testing, and (4) improving the characterization of the waves near the fire boom. 16 refs., 6 figs

  16. Earthquake resistant design of structures

    International Nuclear Information System (INIS)

    Choi, Chang Geun; Kim, Gyu Seok; Lee, Dong Geun

    1990-02-01

    This book tells of occurrence of earthquake and damage analysis of earthquake, equivalent static analysis method, application of equivalent static analysis method, dynamic analysis method like time history analysis by mode superposition method and direct integration method, design spectrum analysis considering an earthquake-resistant design in Korea. Such as analysis model and vibration mode, calculation of base shear, calculation of story seismic load and combine of analysis results.

  17. Internal fire protection analysis for the United Kingdom EPR design

    Energy Technology Data Exchange (ETDEWEB)

    Laid, Abdallah [Nuclear New Build Generation Company Ltd. (NNB GenCo), Barnwood (United Kingdom). EDF Energy Plc.; Cesbron, Mickael [Service Etudes et Project Thermiques et Nucleaires (SEPTEN), Lyon (France). EDF-SA

    2015-12-15

    In the deterministic design basis analysis of the United Kingdom (UK) EPR based nuclear power plants all postulated initiating events are grouped into two different types, internal faults and internal/external hazards. ''Internal Fires'' is one of the internal hazards analysed at the design stage of the UK EPR. In effect, the main safety objective for fire protection is to ensure that all the required safety functions are performed in the event of an internal fire. To achieve this safety objective, provisions for protection against fire risks are taken to: (i) limit the spread of a fire, protect the safety functions of the facility; (ii) limit the propagation of smoke and dispersion of toxic, radioactive, inflammable, corrosive or explosive materials, and (iii) ensure the achievement of a safe shutdown state, personnel evacuation and all other necessary emergency actions. This paper presents the UK EPR approach on how the above provisions are applied. Such provisions involve implementing means of fire prevention, surveillance, firefighting and limiting fire consequences, appropriate to the risks inherent to the facility. Overall, the design of the UK EPR fire protection systems is based on three types of measures: prevention, containment and control.

  18. Fabrics for fire resistant passenger seats in aircraft

    Science.gov (United States)

    Tesoro, G. C.

    1978-01-01

    The essential elements of the problem and of approaches to improved fire resistance in aircraft seats are reviewed. The performance requirements and availability of materials, delay in the ignition of upholstery fabric by a small source are considered a realistic objective. Results of experimental studies on the thermal response of fabrics and fabric/foam combinations suggest significant conclusions regarding: (1) the ignition behavior of a commercial 90/10 wool/nylon upholstery fabric relative to fabrics made from thermally stable polymers; (2) the role of the foam backing; (3) the behavior of seams. These results, coupled with data from other sources, also confirm the importance of materials' interactions in multicomponent assemblies, and the need for system testing prior to materials' selection. The use of an interlinear or thermal barrier between upholstery fabric and foam is a promising and viable approach to improved fire resistance of the seat assembly, but experimental evaluation of specific combinations of materials or systems is an essential part of the selection process.

  19. Japanese studies on sodium fires, design and testing

    International Nuclear Information System (INIS)

    Mitsutsuka, N.; Yoshida, N.

    1983-01-01

    Considerations of sodium fires are very important for the design and licensing of LMFBRs. Continuing effort has been made in the study of sodium fires and their consequences since the beginning of the Japanese fast breeder reactor development program. Recent effort is mainly focussed on studies related to Monju, especially on the design and testing of primary cell liners against large sodium spills. Experimental and analytical studies on sodium fires, water release from concrete and sodium concrete reactions are conducted as a part of this study. Some extinguishing agents are also tested against sodium fires. In addition, considerable effort is being made in the development of detection systems for the small sodium leaks before a pipe rupture. This paper briefly summarizes the Japanese status of these sodium fire related activities conducted by Fast Breeder Reactor Development Project of the Power Reactor and Nuclear Fuel Development Corporation (PNC)

  20. Resistance is not futile: The response of hardwoods to fire-caused wounding

    Science.gov (United States)

    Elaine Kennedy Sutherland; Kevin Smith

    2000-01-01

    Fires wound trees; but not all of them, and not always. Specific fire behavior and differences among tree species and individual trees produce variable patterns of wounding and wound response. Our work focuses on the relationships between fire behavior and tree biology to better understand how hardwood trees resist injury to the lower stem and either survive or succumb...

  1. The Calculation and Design of Fire suppression system in the proton accelerator research center

    International Nuclear Information System (INIS)

    Jeon, G. P.; Kim, J. Y.; Cho, J. H.; Min, Y. S.; Mun, K. J.; Cho, J. S.; Nam, J. M.; Park, S. S.; Joo, H. G.

    2010-01-01

    The fire protection system is composed of various fire suppression systems and fire detection and alarm systems. The primary function of the fire protection system is to protect life and property from a fire through detecting fires quickly and suppressing those fires that occur. In this paper, we described the fire suppression system only. The fire suppression system capacity for fire hydrant, the water mist system, sprinkler system and clean agent system is calculated and designed in compliance with the applicable Korean Acts that are applicable to fire protection and the NFSC code

  2. Parametric study for the fire safety design of steel structures

    DEFF Research Database (Denmark)

    Aiuti, Riccardo; Giuliani, Luisa

    2013-01-01

    the considered time of fire exposure. A deeper knowledge on the failure mode of steel structure is however important in order to ensure the safety of the people and properties outside the building. Aim of this paper is to analyze the behaviour of single elements, sub-assemblies and frames exposed to fire...... or hindered thermal expansion induced on the element by the rest of the structure. Nevertheless, restrained thermal expansion is known to significantly affect the behaviour of steel structures in fire, and the compliance with a prescribed resistance class doesn’t ensure the integrity of the building after...... and find out the basic collapse mechanisms of structural elements in fire conditions, considering the rest of the construction with appropriate constraints. The analysis is carried out taking into account material and geometrical nonlinearities as well as the degradation of steel properties at high...

  3. Study of the fire resistant behavior of unfilled and carbon nanofibers reinforced polybenzimidazole coating for structural applications

    OpenAIRE

    Iqbal, H.M.S.; Stec, A.A.; Patel, P.; Bhowmik, S.; Benedictus, R.

    2013-01-01

    With increasing interest in epoxy-based carbon fiber composites for structural applications, it is important to improve the fire resistant properties of these materials. The fire resistant performance of these materials can be improved either by using high performance epoxy resin for manufacturing carbon fiber composite or by protecting the previously used epoxy-based composite with some fire resistant coating. In this context, work is carried out to evaluate the fire resistance performance o...

  4. Increased heat resistance in mycelia from wood fungi prevalent in forests characterized by fire: a possible adaptation to forest fire.

    Science.gov (United States)

    Carlsson, Fredrik; Edman, Mattias; Holm, Svante; Eriksson, Anna-Maria; Jonsson, Bengt Gunnar

    2012-10-01

    Forest fires have been the major stand-replacing/modifying disturbance in boreal forests. To adapt to fire disturbance, different strategies have evolved. This study focuses on wood fungi, and a specific adaptation to forest fire: increased heat resistance in their mycelia. Fifteen species of wood fungi were selected and a priori sorted in two groups according to their prevalence in fire-affected environments. The fungi were cultivated on fresh wood and exposed to 100, 140, 180, 220 °C for 5, 10, 15, 20 and 25 min. under laboratory conditions. A clear difference was found among the two groups. Species prevalent in fire-affected habitats had a much higher survival rate over all combinations of time and temperature compared to species associated with other environments. Thus, the results indicate that fire adaptation in terms of increased heat resistance in mycelia occurs in some species of wood fungi. Such adaptation will influence the ecology and population dynamics of wood fungi, as well as having implications for best practices during restoration fires. Copyright © 2012 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  5. United States position paper on sodium fires, design and testing

    International Nuclear Information System (INIS)

    Hilliard, R.K.; Johnson, R.P.

    1983-01-01

    The first Specialists' Meeting on sodium fire technology sponsored by the International Working Group on Fast Reactors (IWGFR) was held in Richland, Washington in 1972. The group concluded that the state-of-technology at that time was inadequate to support the growing LMFBR industry. During the second IWGFR Specialists' Meeting on sodium fires, held in Cadarache, France in 1978, a large quantity of technical information was exchanged and areas were identified where additional work was needed. Advances in several important areas of sodium fire technology have been made in the United States since that time, including improved computer codes, design of a sodium fire protection system for the CRBRP, measurement of water release from heated concrete, and testing and modeling of the sodium-concrete reaction. Research in the U.S. related to sodium fire technology is performed chiefly at the Energy Systems Group of Rockwell International (including Atomics International), the Hanford Engineering Development Laboratory (HEDL), and the Sandia National Laboratories (SNL). The work at the first two laboratories is sponsored by the U.S. Department of Energy, while that at the latter is sponsored by the U.S. Nuclear Regulatory Commission. Various aspects of sodium fire related work is also performed at several other laboratories. The current status of sodium fire technology in the U.S. is summarized in this report

  6. Development of fire-resistant, low smoke generating, thermally stable end items for aircraft and spacecraft

    Science.gov (United States)

    Gagliani, J.; Sorathia, U. A. K.; Wilcoxson, A. L.

    1977-01-01

    Materials were developed to improve aircraft interior materials by modifying existing polymer structures, refining the process parameters, and by the use of mechanical configurations designed to overcome specific deficiencies. The optimization, selection, and fabrication of five fire resistant, low smoke emitting open cell foams are described for five different types of aircraft cabin structures. These include: resilient foams, laminate floor and wall paneling, thermal/acoustical insulation, molded shapes, and coated fabrics. All five have been produced from essentially the same polyimide precursor and have resulted in significant benefits from transfer of technology between the various tasks.

  7. Fire resistivity of irradiated nuclear fuel shipping cask

    International Nuclear Information System (INIS)

    Shimada, Hirohisa

    1975-01-01

    The fire resistance of lead-lined casks was examined and compared with that of a cask without lead lining. Three cask models with 1/8 radius of actual casks and one with 1/4 radius were used, each one is composed of three layers, i.e. steel outer shell, lead shield, and stainless steel inner shell. The models were heated in an oil furnace only from their side at 800 0 C and cooled in the furnace. During the experiment, the temperature in the furnace and of the models were recorded continuously. The lead shield of the models started to melt 5--7 min after the start of heating. The temperature difference between the outer shell and the lead shield of the models was larger in case of the model without lead lining treatment than the models with it, and it is attributable to the low heat conductivity of the gap between the outer shell and the lead shield. The heat transfer property of casks was affected by the fabricating method of the casks. The temperature at the outer shell and that at the lead shield were calculated, and the results agreed considerably well with the experimental values, when 180 and 1800 kcal/m 2 h 0 C were employed as the heat conductivity of the gaps of the models. The gaps were estimated as 0.23 mm and 0.023 mm, respectively. In order to dissipate effectively the heat generated by contained fuel, lead lining treatment is necessary before pouring molten lead for shielding, but when the casks with the lead lining treatment are exposed to fire, the lead shield cannot keep its integrity. (Kako, I.)

  8. Resistance of eastern hardwood stems to fire injury and damage

    Science.gov (United States)

    Kevin T. Smith; Elaine Kennedy Sutherland

    2006-01-01

    This paper reviews the protective features and defensive responses of eastern hardwood species exposed to fire. Trees survive fire through protective features such as thick bark and the induced defenses of compartmentalization. Dissection of trees exposed to prescribed fire in an oak forest in southern Ohio highlights the need to distinguish between bark scorch, stem...

  9. Performance of Link-To-Stub Bolted Connection in Column-Tree Moment Resisting Frames under Fire Conditions

    Directory of Open Access Journals (Sweden)

    Mahmood Yahyai

    2015-12-01

    Full Text Available Column-tree moment resisting frames, as the efficient shop-welded and field-bolted structural systems, are used in many countries. Very limited research has been carried out on such systems under fire conditions. This paper presents experimental investigations of the behavior of beam and bolted splice connections in steel column-tree moment resisting frames exposed to fire. Two full-scale steel sub-frames with different splice connections were tested under ISO 834 standard fire. The flange splice plates were configured as a single plate with single shear bolts in first specimen, and as double plates with double shear bolts in second specimen. The observation of thermal and structural fire behaviors including temperature histories, temperature-deflection of the beam, temperature-rotation of splice connections and failure modes were investigated. The temperature-deflection and temperature-rotation curves remained in the elastic range until about 600°C. Beyond 600°C, the behavior would be highly nonlinear plastic. The beam splice connection failed due to shear fracture of top bolts at temperatures beyond 750°C. Consequently, stub beam web failed at those temperatures because of block-shear. Using double plates with double shear bolts for flange splices would enhance the temperature resistance and rotational capacity of the beam splice connections. Both tests results confirmed that specimens retain the capacity to support the design load when the average beam temperature does not exceed 600°C. This temperature limit confirms the temperature criteria provided by ASTM E119 and ANSI/UL 263 for a restrained beam, and can be used to specify the minimum fire resistance criteria for beams in column-tree MRFs. The measured time-deflection curves showed that the restrained fire resistance rating for both unprotected specimens obtained about 15 minutes in both tests.

  10. Research of the Fire Resistance оf Translucent and Composite Facade System

    Directory of Open Access Journals (Sweden)

    Nedryshkin Oleg

    2016-01-01

    Full Text Available The paper aims at researching fire resistance of a prototype facade system “Technocom” (type Alucobond A2. Experimental and theoretical research of fire hazard facade system is carried out. The objectives of the study are to determine compliance with the applicable front of special technical requirements. The status of problem reducing fire hazard facade system is reviewed. The method developed by compensatory measures is applied.

  11. Design and Implementation of Fire Extinguisher Robot with Robotic Arm

    Directory of Open Access Journals (Sweden)

    Memon Abdul Waris

    2018-01-01

    Full Text Available Robot is a device, which performs human task or behave like a human-being. It needs expertise skills and complex programming to design. For designing a fire fighter robot, many sensors and motors were used. User firstly send robot to an affected area, to get live image of the field with the help of mobile camera via Wi-Fi using IP camera application to laptop. If any signs of fire shown in image, user direct robot in that particular direction for confirmation. Fire sensor and temperature sensor detects and measures the reading, after confirmation robot sprinkle water on affected field. During extinguish process if any obstacle comes in between the prototype and the affected area the ultrasonic sensor detects the obstacle, in response the robotic arm moves to pick and place that obstacle to another location for clearing the path. Meanwhile if any poisonous gas is present, the gas sensor detects and indicates by making alarm.

  12. A New Design Method for Industrial Portal Frames in Fire

    Directory of Open Access Journals (Sweden)

    Y. Song

    2009-01-01

    Full Text Available Industrial portal frames near to other buildings must keep their vertical walls standing in fire in order to prevent fire spread.  A recently developed analysis, implemented in the program Vulcan, using a combination of static and dynamic solvers, has shown that the strong base connections recommended by the current design method may not always lead to conservative design. A second-phase failure mechanism observed in numerical modelling, and the critical temperature at which final run-away collapse occurs, may be higher than the temperature at which the roof frame initially loses its stability, because a re-stabilisation often happens.  A new method for estimating critical temperatures of portal frames in fire, using these two failure mechanisms, is presented. Numerical tests on typical industrial frames are used to calibrate this new method. 

  13. Use of numerical modeling in design for co-firing biomass in wall-fired burners

    DEFF Research Database (Denmark)

    Yin, Chungen; Rosendahl, Lasse Aistrup; Kær, Søren Knudsen

    2004-01-01

    modification to the motion and reaction due to their non-sphericity. The simulation results show a big difference between the two cases and indicate it is very significant to take into account the non-sphericity of biomass particles in order to model biomass combustion more accurately. Methods to improve...... of numerical modeling. The models currently used to predict solid fuel combustion rely on a spherical particle shape assumption, which may deviate a lot from reality for big biomass particles. A sphere gives a minimum in terms of the surface-area-to-volume ratio, which impacts significantly both motion...... and reaction of a particle. To better understand biomass combustion and thus improve the design for co-firing biomass in wall-fired burners, non-sphericity of biomass particles is considered. To ease comparison, two cases are numerically studied in a 10m long gas/biomass co-fired burner model. (1) The biomass...

  14. Fire Risk Analysis and Optimization of Fire Prevention Management for Green Building Design and High Rise Buildings: Hong Kong Experience

    Directory of Open Access Journals (Sweden)

    Yau Albert

    2014-12-01

    Full Text Available There are many iconic high rise buildings in Hong Kong, for example, International Commercial Centre, International Financial Centre, etc. Fire safety issue in high rise buildings has been raised by local fire professionals in terms of occupant evacuation, means of fire-fighting by fire fighters, sprinkler systems to automatically put off fires in buildings, etc. Fire risk becomes an important issue in building fire safety because it relates to life safety of building occupants where they live and work in high rise buildings in Hong Kong. The aim of this research is to identify the fire risk for different types of high rise buildings in Hong Kong and to optimise the fire prevention management for those high rise buildings with higher level of fire risk and to validate the model and also to carry out the study of the conflict between the current fire safety building code and the current trend of green building design. Survey via the 7-point scale questionnaire was conducted through 50 participants and their responses were received and analysed via the statistical tool SPSS software computer program. A number of statistical methods of testing for significantly difference in samples were adopted to carry out the analysis of the data received. When the statistical analysis was completed, the results of the data analysis were validated by two Fire Safety Experts in this area of specialisation and also by quantitative fire risk analysis.

  15. Probabilistic Evaluation of Eurocode 5 Fire Design Criteria of a ...

    African Journals Online (AJOL)

    Structural reliability analysis for a three-hinge timber portal frame subjected to fire was undertaken. Eight modes of failure were identified for the frame and limit state function was formulated for each failure mode. The limit state functions were based on the Eurocode 5 design criteria. Uncertainties in the timber material ...

  16. Unified Facilities Criteria (UFC) Design: Fire Protection Engineering for Facilities

    Science.gov (United States)

    2003-08-20

    following provisions: • Ceiling sprinkler design area must be increased by 10 percent. ESFR sprinklers must increase the required number to be...Control System ESFR Early Suppression Fast-Response Sprinklers ETL Engineering Technical Letters FAAA Fire Administration Authorization Act FM

  17. Effect of Environmental Variables on the Flammability of Fire Resistant Materials

    OpenAIRE

    Osorio, Andres Felipe

    2014-01-01

    This work investigates the effects of external radiation, ambient pressure and microgravity on the flammability limits of fire-resistant (FR) materials. Future space missions may require spacecraft cabin environments different than those used in the International Space Station, 21%O2, 101.3kPa. Environmental variables include flow velocity, oxygen concentration, ambient pressure, micro or partial-gravity, orientation, presence of an external radiant flux, etc. Fire-resistant materials are use...

  18. Design guides for cell atmosphere controls, utilities and fire protection

    International Nuclear Information System (INIS)

    Hill, A.J. Jr.; Peishel, F.L.; Slattery, E.F.

    1981-01-01

    Facilities for handling radioactive and toxic materials must be designed not only for efficient operation, but also for protection of the operating personnel and the public. The ventilation system is of primary importance in maintaining containment of any airborne radioactivity. The type, number, and location of in-cell services must be adequate for planned operations, but also must allow flexibility to accommodate expansion in the scope of operations or changes in programs. Fire protection systems and operational controls are mandatory to maintain containment of radioactivity in the event of an operating error or process accident that may result in a fire

  19. Luminescent, Fire-Resistant, and Water-Proof Ultralong Hydroxyapatite Nanowire-Based Paper for Multimode Anticounterfeiting Applications.

    Science.gov (United States)

    Yang, Ri-Long; Zhu, Ying-Jie; Chen, Fei-Fei; Dong, Li-Ying; Xiong, Zhi-Chao

    2017-08-02

    Counterfeiting of valuable certificates, documents, and banknotes is a serious issue worldwide. As a result, the need for developing novel anticounterfeiting materials is greatly increasing. Herein, we report a new kind of ultralong hydroxyapatite nanowire (HAPNW)-based paper with luminescence, fire resistance, and waterproofness properties that may be exploited for anticounterfeiting applications. In this work, lanthanide-ion-doped HAPNWs (HAPNW:Ln 3+ ) with lengths over 100 μm have been synthesized and used as a raw material to fabricating a free-standing luminescent, fire-resistant, water-proof paper through a simple vacuum filtration process. It is interesting to find that the luminescence intensity, structure, and morphology of HAPNW:Ln 3+ highly depend on the experimental conditions. The as-prepared HAPNW:Ln 3+ paper has a unique combination of properties, such as high flexibility, good processability, writing and printing abilities, luminescence, tunable emission color, waterproofness, and fire resistance. In addition, a well-designed pattern can be embedded in the paper that is invisible under ambient light but viewable as a luminescent color under ultraviolet light. Moreover, the HAPNW:Ln 3+ paper can be well-preserved without any damage after being burned by fire or soaked in water. The unique combination of luminescence, fire resistance, and waterproofness properties and the nanowire structure of the as-prepared HAPNW:Ln 3+ paper may be exploited toward developing a new kind of multimode anticounterfeiting technology for various high-level security antiforgery applications, such as in making forgery-proof documents, certificates, labels, and tags and in packaging.

  20. FIRE-RESISTANCE PROPERTIES RESEARCH OF “WATER GLASS - GRAPHITE MICROPARTICLES” COMPOSITE MATERIAL

    Directory of Open Access Journals (Sweden)

    E. A. Pitukhin

    2016-03-01

    Full Text Available Subject of Research. Research results of the fire-resistance for “water glass - graphite microparticles” composite material (CM are given. The method for fire-resistance test of the micro composition is suggested in order to determine the limit state of the experimental samples under hightemperature action. Method. Test-benchequipment being used for research includes metering devices of temperature and time, as well as laboratory electric furnace PL20 with a maximum temperature in the chamber up to 1250ºC. Fire-resistance limit for the test samples of composite material is determined by the loss of insulating ability (I. For that purpose, the time is obtained from the test beginning with the standard temperature mode up to a limiting condition. Main Results. In accordance with the requirements of regulatory documents fire-resistance limit I15 has been obtained equal to 15 minutes. The qualitative and quantitative phase analysis of the CM structure has been done. By the study of samples by X-ray diffraction and electron microscopy we have determined that the material retains the same chemical structure with a monotonic heating above 700° C. Practical Relevance. The composite material with obtained characteristics can be used as a protective coating for building constructions with the aim of fire-resistance enhancement and fuel hazard reduction.

  1. Ecological fire use for ecological fire management: Managing large wildfires by design

    Science.gov (United States)

    Timothy Ingalsbee

    2015-01-01

    Past fire exclusion policies and fire suppression actions have led to a historic "fire deficit" on public wildlands. These sociocultural actions have led to unprecedented environmental changes that have created conditions conducive to more frequent large-scale wildfires. Politicians, the newsmedia, and agency officials portray large wildland fires as...

  2. FIRE-RESISTANT SHIELDING COATING BASED ON SHUNGITE-CONTAINING PAINT

    Directory of Open Access Journals (Sweden)

    BELOUSOVA Elena Sergeevna

    2013-08-01

    Full Text Available Today when specific shielded facilities are designed the construction materials and shields should meet a range of fire safety requirements. A composite coating on the basis of a water-based fire-resistant paint filled with shungite nanopowder can be applied onto walls, floors, ceilings and other surfaces in the shielded areas to reduce electromagnetic radiation and simultaneously to ensure fire safety. Shungit is a mineral with multilayer carbon fullerene globules which diameter is 10–30 nm. Due to the high conductivity shungite is able to weaken electromagnetic radiation. A coating made of schungite-containing paint on a cellulose substrate was subjected to the open flame under the temperature of 1700° C for 3 minutes and 40 seconds. That resulted in the formation of insulating foam layer without mechanical damage of the substrate. The XRD diffraction analysis of the powder obtained in the process of flame influence on the coating showed the formation of the such substances as orthoclase, barite, rutile, etc. Carbon contained in shungit and used as a filler for the fireproof paint wasn’t detected. This fact indicates carbon oxidation as the result of its burning out. The shielding efficiency of the composite coating after open flame exposure was measured for the frequency range 8…12 GHz with the use of the panoramic attenuation meter and voltage standing wave ratio meter YA2R-67-61 with a sweep generator and waveguides. After that the reflection and transmission coefficients were calculated. The results of measurements and calculations showed decrease of the reflection and transmission coefficients due to conductivity decrease and dielectric losses changes of the composite coating provided by silica content increase and carbon percentage decrease.

  3. Effect of Spacecraft Environmental Variables on the Flammability of Fire Resistant Fabrics

    Science.gov (United States)

    Osorio, A. F.; Fernandez-Pello, C.; Takahashi, S.; Rodriguez, J.; Urban, D. L.; Ruff, G.

    2012-01-01

    Fire resistant fabrics are used for firefighter, racecar drivers as well as astronaut suits. However, their fire resistant characteristics depend on the environment conditions and require study. Particularly important is the response of these fabrics to elevated oxygen concentration environments and radiant heat from a source such as an adjacent fire. In this work, experiments using two fire resistant fabrics were conducted to study the effect of oxygen concentration, external radiant flux and oxidizer flow velocity in concurrent flame spread. Results show that for a given fabric the minimum oxygen concentration for flame spread depends strongly on the magnitude of the external radiant flux. At increased oxygen concentrations the external radiant flux required for flame spread decreases. Oxidizer flow velocity influences the external radiant flux only when the convective heat flux from the flame has similar values to the external radiant flux. The results of this work provide further understanding of the flammability characteristics of fire resistant fabrics in environments similar to those of future spacecrafts.

  4. Termites Are Resistant to the Effects of Fire at Multiple Spatial Scales.

    Directory of Open Access Journals (Sweden)

    Sarah C Avitabile

    Full Text Available Termites play an important ecological role in many ecosystems, particularly in nutrient-poor arid and semi-arid environments. We examined the distribution and occurrence of termites in the fire-prone, semi-arid mallee region of south-eastern Australia. In addition to periodic large wildfires, land managers use fire as a tool to achieve both asset protection and ecological outcomes in this region. Twelve taxa of termites were detected by using systematic searches and grids of cellulose baits at 560 sites, clustered in 28 landscapes selected to represent different fire mosaic patterns. There was no evidence of a significant relationship between the occurrence of termite species and time-since-fire at the site scale. Rather, the occurrence of species was related to habitat features such as the density of mallee trees and large logs (>10 cm diameter. Species richness was greater in chenopod mallee vegetation on heavier soils in swales, rather than Triodia mallee vegetation of the sandy dune slopes. At the landscape scale, there was little evidence that the frequency of occurrence of termite species was related to fire, and no evidence that habitat heterogeneity generated by fire influenced termite species richness. The most influential factor at the landscape scale was the environmental gradient represented by average annual rainfall. Although termites may be associated with flammable habitat components (e.g. dead wood, they appear to be buffered from the effects of fire by behavioural traits, including nesting underground, and the continued availability of dead wood after fire. There is no evidence to support the hypothesis that a fine-scale, diverse mosaic of post-fire age-classes will enhance the diversity of termites. Rather, termites appear to be resistant to the effects of fire at multiple spatial scales.

  5. LMFBR plant design features for sodium spill and fire protection

    International Nuclear Information System (INIS)

    Palm, R.E.

    1982-01-01

    Design features have been developed for an LMFBR plant to protect the concrete structures from potential liquid spills and fires and prevent sodium-concrete reactions. The inclusion of these features in the plant design reduces the severity of design basis accident conditions imposed on containment and other critical plant structures. Steel liners are provided in cells containing radioactive sodium systems, and catch pans are located in non-radioactive sodium system cells. The design requirements and descriptions of each of these protective features are presented. The loading conditions, analytical approach and numerical results are also included. Design of concrete cell structures that are subject to high temperature effects from sodium spills is discussed. The structural design considers the influence of high temperature on design properties of concrete and carbon steel materials based on results of a comprehensive test program. The development of these design features and high temperature design considerations for the Clinch River Breeder Reactor Plant (CRBRP) are presented in this paper

  6. Fire resistant polyamide based on 1-(diorganooxyphosphonyl)methyl-2,4- and -2,6diamino benzene

    Science.gov (United States)

    Mikroyannidis, J. A. (Inventor); Kourtides, D. A. (Inventor)

    1986-01-01

    1-(Diorganooxyphosphonyl)methyl2,4- and-2,6diamino benzenes are reacted with polyacylhalides and optionally comonomers to produce polyamides which have desirable heat and fire resistance properties. These polymers are used to form fibers and fabrics where fire resistance properties are important, e.g., aircraft equipment and structures.

  7. 49 CFR 178.358 - Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack. 178.358 Section 178.358 Transportation Other Regulations Relating... Class 7 (Radioactive) Materials § 178.358 Specification 21PF fire and shock resistant, phenolic-foam...

  8. Study of the fire resistant behavior of unfilled and carbon nanofibers reinforced polybenzimidazole coating for structural applications

    NARCIS (Netherlands)

    Iqbal, H.M.S.; Stec, A.A.; Patel, P.; Bhowmik, S.; Benedictus, R.

    2013-01-01

    With increasing interest in epoxy-based carbon fiber composites for structural applications, it is important to improve the fire resistant properties of these materials. The fire resistant performance of these materials can be improved either by using high performance epoxy resin for manufacturing

  9. Fire-Resistant Hydrogel-Fabric Laminates: A Simple Concept That May Save Lives.

    Science.gov (United States)

    Illeperuma, Widusha R K; Rothemund, Philipp; Suo, Zhigang; Vlassak, Joost J

    2016-01-27

    There is a large demand for fabrics that can survive high-temperature fires for an extended period of time, and protect the skin from burn injuries. Even though fire-resistant polymer fabrics are commercially available, many of these fabrics are expensive, decompose rapidly, and/or become very hot when exposed to high temperatures. We have developed a new class of fire-retarding materials by laminating a hydrogel and a fabric. The hydrogel contains around 90% water, which has a large heat capacity and enthalpy of vaporization. When the laminate is exposed to fire, a large amount of energy is absorbed as water heats up and evaporates. The temperature of the hydrogel cannot exceed 100 °C until it is fully dehydrated. The fabric has a low thermal conductivity and maintains the temperature gradient between the hydrogel and the skin. The laminates are fabricated using a recently developed tough hydrogel to ensure integrity of the laminate during processing and use. A thermal model predicts the performance of the laminates and shows that they have excellent heat resistance in good agreement with experiments, making them viable candidates in life saving applications such as fire-resistant blankets or apparel.

  10. Calculation of Limits of Fire Resistance for Structures with Fire Retardant Coating

    Directory of Open Access Journals (Sweden)

    Krivtcov Artem

    2016-01-01

    Full Text Available This article is devoted to fireproof processing of steel structures. The main task is to consider different types of sections of rod elements and to choose the most effective section for a steel column from the point of view of fire protection. For the solution of this task the steel columns with various cross sections working in identical entry conditions were considered. All necessary calculations for all types of sections were carried out. Results of calculations were presented in the summary table according to which the comparative analysis was made. At the end of work the conclusion that the compound section from four equal corners is the most effective from the point of view of fire protection.

  11. Role of Firing Temperature, Sheet Resistance, and Contact Area in Contact Formation on Screen-Printed Metal Contact of Silicon Solar Cell

    Science.gov (United States)

    Ahmad, Samir Mahmmod; Leong, Cheow Siu; Sopian, K.; Zaidi, Saleem H.

    2018-03-01

    Formation of an Ohmic contact requires a suitable firing temperature, appropriate doping profile, and contact dimensions within resolution limits of the screen-printing process. In this study, the role of the peak firing temperature in standard rapid thermal annealing (RTA) six-zone conveyor belt furnace (CBF) and two inexpensive alternate RTA systems [a custom-designed, three-zone, 5″-diameter quartz tube furnace (QTF) and a tabletop, 3″-diameter rapid thermal processing (RTP)] has been investigated. In addition, the role of sheet resistance and contact area in achieving low-resistance ohmic contacts has been examined. Electrical measurements of ohmic contacts between silver paste/ n +-emitter layer with varying sheet resistances and aluminum paste/ p-doped wafer were carried out in transmission line method configuration. Experimental measurements of the contact resistivity ( ρ c) exhibited the lowest values for CBF at 0.14 mΩ cm2 for Ag and 100 mΩ cm2 for Al at a peak firing temperature of 870°C. For the QTF configuration, lowest measured contact resistivities were 3.1 mΩ cm2 for Ag and 74.1 mΩ cm2 for Al at a peak firing temperature of 925°C. Finally, for the RTP configuration, lowest measured contact resistivities were 1.2 mΩ cm2 for Ag and 68.5 mΩ cm2 for Al at a peak firing temperature of 780°C. The measured contact resistivity exhibits strong linear dependence on sheet resistance. The contact resistivity for Ag decreases with contact area, while for Al the opposite behavior is observed.

  12. Cold Vacuum Dryer (CVD) Facility Fire Protection System Design Description (SYS 24)

    Energy Technology Data Exchange (ETDEWEB)

    SINGH, G.

    2000-10-17

    This system design description (SDD) addresses the Cold Vacuum Drying (CVD) Facility fire protection system (FPS). The primary features of the FPS for the CVD are a fire alarm and detection system, automatic sprinklers, and fire hydrants. The FPS also includes fire extinguishers located throughout the facility and fire hydrants to assist in manual firefighting efforts. In addition, a fire barrier separates the operations support (administrative) area from the process bays and process bay support areas. Administrative controls to limit combustible materials have been established and are a part of the overall fire protection program. The FPS is augmented by assistance from the Hanford Fire Department (HED) and by interface systems including service water, electrical power, drains, instrumentation and controls. This SDD, when used in conjunction with the other elements of the definitive design package, provides a complete picture of the FPS for the CVD Facility.

  13. Designing for resistance to disaster

    International Nuclear Information System (INIS)

    1970-01-01

    Tsunami is a Japanese word from a double root: tsu, meaning port or harbour, and nami, meaning wave. The word looks innocuous in simple translation, but to those who live on the rim of the Pacific it can spell disaster. The designers of nuclear installations at coastal sites, in particular, must take the possibility of occurrence of a tsunami into account in their work. (author)

  14. Design and Development of Fire Gridding Platform Based on Internet of Things

    Directory of Open Access Journals (Sweden)

    Wei San-Xi

    2016-01-01

    Full Text Available This article describes the construction background about fire gridding platform, reviews the research and progress in fire Internet of Things and fire gridding. The platform includes perception / execution layer, field control layer, network layer, center platform layer and application layer, which provide a good bonding about site control and remote monitoring. This article supplies a detail design for the main functions of application and task flow of fire hazard investigation. At the same time, a digital management platform was developed.

  15. Designing an Earthquake-Resistant Building

    Science.gov (United States)

    English, Lyn D.; King, Donna T.

    2016-01-01

    How do cross-bracing, geometry, and base isolation help buildings withstand earthquakes? These important structural design features involve fundamental geometry that elementary school students can readily model and understand. The problem activity, Designing an Earthquake-Resistant Building, was undertaken by several classes of sixth- grade…

  16. Optimization of investment economic in PCI using the methodology of benefits design in analysis of the spread of fires with FDS (Fire Dynamics Simulator) in areas of nuclear fire

    International Nuclear Information System (INIS)

    Salellas, J.

    2015-01-01

    Fire simulation analysis allows knowing the evolution and spread fire in areas of interest within a NPP such as control room, cable room and multi zone comportment among others. fires are a main concern regarding safety analysis of NPP. IDOM has the capability to carry out fire simulations, taken in to account smoke control, fire spread, toxicity levels, ventilation and all physical phenomena. As a result, appropriate fire protection measures can be assessed in each scenario. CFD tools applied to fire simulations can determine with higher resolution all damages caused during the fire. Furthermore, such tools can reduce costs due to a lower impact of design modifications. (Author)

  17. Mission and design of the Fusion Ignition Research Experiment (FIRE)

    International Nuclear Information System (INIS)

    Meade, D.M.; Jardin, S.C.; Schmidt, J.

    2001-01-01

    Experiments are needed to test and extend present understanding of confinement, macroscopic stability, alpha-driven instabilities, and particle/power exhaust in plasmas dominated by alpha heating. A key issue is to what extent pressure profile evolution driven by strong alpha heating will act to self-organize advanced configurations with large bootstrap current fractions and internal transport barriers. A design study of a Fusion Ignition Research Experiment (FIRE) is underway to assess near term opportunities for advancing the scientific understanding of self-heated fusion plasmas. The emphasis is on understanding the behavior of fusion plasmas dominated by alpha heating (Q≥5) that are sustained for durations comparable to the characteristic plasma time scales (≥20 τ E and ∼τ skin , where τ skin is the time for the plasma current profile to redistribute at fixed current). The programmatic mission of FIRE is to attain, explore, understand and optimize alpha-dominated plasmas to provide knowledge for the design of attractive magnetic fusion energy systems. The programmatic strategy is to access the alpha-heating-dominated regime with confidence using the present advanced tokamak data base (e.g., Elmy-H-mode, ≤0.75 Greenwald density) while maintaining the flexibility for accessing and exploring other advanced tokamak modes (e. g., reversed shear, pellet enhanced performance) at lower magnetic fields and fusion power for longer durations in later stages of the experimental program. A major goal is to develop a design concept that could meet these physics objectives with a construction cost in the range of $1B. (author)

  18. New methods for testing fire resistance of wood façade systems

    Directory of Open Access Journals (Sweden)

    Mårtensson August

    2016-01-01

    Full Text Available Arson in schools has been a huge problem in Sweden over the last fifteen years. The average amount of school arsons between 2000 and 2014 was 285 cases each year which corresponds to 50% of the total amount of reported fires in school buildings. This is a well-known problem and a lot of research has been done in this area. Investigations has been done about fire and heat detection systems, different technical factors significance in fire scenarios and how to prevent adolescents from starting fires. Another part of the problem that partly been investigated is how the schools are constructed. Roughly 50% of the arsons are outside of the school building. In Sweden one and two storey buildings are allowed to be built with wooden façades in accordance with the building code, which is one of the reasons many schools are built with wooden façade systems. The most critical part in a wood façade system from a fire safety perspective is concluded to be the eaves because of how they usually are built to let air pass through. Even though a wood façade isn't as well resistant to fire compared to a concrete façade, three versions of new test methods for combustible façades have been developed to make it possible to make sure in advance that a construction is resistant enough. The new test methods are focused on specific details and parts of a façade system to provide a more informative and useful result compared to SP Fire 105. Observations and measurements of flame spread and temperature changes in the eave, over the window joints and in the air gap are made. With these parameters in consideration criteria's has been chosen for a critical temperature of 280 ∘C at a critical time of 20 minutes.

  19. The improvement for fire retardant and radiation resistance characteristics of chloroprene rubber

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K. Y.; Lee, C.; Kim, P. J.; Kim, J. H

    2004-04-01

    In the report, in order to improve the fire retardancy better Chloroprene Rubber (CR) after adding each fixed amount of inorganic metallic hydroxide, and then compared and assessed fire retardancy with electrical properties and mechanical properties we intended to choose the most excellent additives. Also according to Co{sup 60} {gamma}-ray irradiation, we compared electrical, echanical and fire retardant characteristics to analyse to have the additives of inorganic filler effect on CR's antirad characteristic. In result, CR containing inorganic additive, advanced considerably fire retardant characteristics, but seems to be tended to declined electrical and mechanical characteristics on the whole. In syntherically comparison, the specimen viewed the most excellent characteristics is CR containing Magnesium hydroxide. As to Co{sup 60} {gamma}-ray irradiated Chloroprene rubber containing inorganic additives, fire retardant characteristic are improved, but electrical and mechanical properties are deteriorated as a function of radiation dose. Comparing before irradiation and after irradiation, the best inorganic filler into CR consider Magnesium hydroxide. In this report, in case of adding 30 phr of inorganic filler to CR we observed fire retardancy and radiation resistance characteristics change in according to the kinds of additives, but the research for choosing the optimum amount of additives is considered to progress from now on as adjusting the amount of additives presented excellent characteristics.

  20. Rootstock-regulated gene expression patterns associated with fire blight resistance in apple

    Directory of Open Access Journals (Sweden)

    Jensen Philip J

    2012-01-01

    Full Text Available Abstract Background Desirable apple varieties are clonally propagated by grafting vegetative scions onto rootstocks. Rootstocks influence many phenotypic traits of the scion, including resistance to pathogens such as Erwinia amylovora, which causes fire blight, the most serious bacterial disease of apple. The purpose of the present study was to quantify rootstock-mediated differences in scion fire blight susceptibility and to identify transcripts in the scion whose expression levels correlated with this response. Results Rootstock influence on scion fire blight resistance was quantified by inoculating three-year old, orchard-grown apple trees, consisting of 'Gala' scions grafted to a range of rootstocks, with E. amylovora. Disease severity was measured by the extent of shoot necrosis over time. 'Gala' scions grafted to G.30 or MM.111 rootstocks showed the lowest rates of necrosis, while 'Gala' on M.27 and B.9 showed the highest rates of necrosis. 'Gala' scions on M.7, S.4 or M.9F56 had intermediate necrosis rates. Using an apple DNA microarray representing 55,230 unique transcripts, gene expression patterns were compared in healthy, un-inoculated, greenhouse-grown 'Gala' scions on the same series of rootstocks. We identified 690 transcripts whose steady-state expression levels correlated with the degree of fire blight susceptibility of the scion/rootstock combinations. Transcripts known to be differentially expressed during E. amylovora infection were disproportionately represented among these transcripts. A second-generation apple microarray representing 26,000 transcripts was developed and was used to test these correlations in an orchard-grown population of trees segregating for fire blight resistance. Of the 690 transcripts originally identified using the first-generation array, 39 had expression levels that correlated with fire blight resistance in the breeding population. Conclusions Rootstocks had significant effects on the fire blight

  1. RCC-F: Design and construction rules for PWR fire protection systems

    International Nuclear Information System (INIS)

    2013-01-01

    The RCC-F code defines the rules for designing, building and installing the fire protection systems used to manage the nuclear hazards inherent in the outbreak of a fire inside the facility and thereby control the fundamental nuclear functions. The code provides fire protection recommendations in terms of: the industrial risk (loss of assets and/or operation), personnel safety, the environment. The code is divided into five main sections: generalities, design safety principles, fire protection design bases, construction provisions, rules for installing the fire protection components and equipment. The RCC-F code is available as an ETC-F version specifically for EPR projects (European pressurized reactor). Contents of the 2013 edition of the ETC-F code: Volume A - Generalities: Structure of ETC-F general points, documentation (in progress), chapter (provision) quality assurance; Volume B - Design safety principles: design nuclear safety principles; Volume C - Fire protection design bases: fire protection design bases; Volume D - Construction provisions: construction provisions; Volume E - Installation rules for fire protection: rules for installing the fire protection, components and equipment

  2. Fracture Resistance of Zirconia Restorations with a Modified Framework Design

    Directory of Open Access Journals (Sweden)

    sakineh Nikzadjamnani

    2017-12-01

    Full Text Available Objectives: Chipping is one of the concerns related to zirconia crowns. The reasons of chipping have not been completely understood. This in-vitro study aimed to assess the effect of coping design on the fracture resistance of all-ceramic single crowns with zirconia frameworks. Materials and Methods: Two types of zirconia copings were designed (n=12: (1 a standard coping (SC with a 0.5mm uniform thickness and (2 a modified coping (MC consisted of a lingual margin of 1mm thickness and 2mm height connected to a proximal strut of 4mm height and a 0.3mm-wide facial collar. After veneer porcelain firing, the crowns were cemented to metal dies. Afterwards, a static vertical load was applied until failure. The modes of failure were determined. Data were calculated and statistically analyzed by independent samples T-test. P<0.05 was considered statistically significant.Results: The mean and standard deviation (SD of the final fracture resistance equaled to 3519.42±1154.96 N and 3570.01±1224.33 N in SC and MC groups, respectively; the difference was not statistically significant (P=0.9. Also, the mean and SD of the initial fracture resistance equaled to 3345.34±1190.93 N and 3471.52±1228.93 N in SC and MC groups, respectively (P=0.8. Most of the specimens in both groups showed the mixed failure mode. Conclusions: Based on the results, the modified core design may not significantly improve the fracture resistance.

  3. Cold Vacuum Drying facility fire protection system design description

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) fire protection system (FPS). The FPS provides fire detection, suppression, and loss limitation for the CVDF structure, personnel, and in-process spent nuclear fuel. The system provides, along with supporting interfacing systems, detection, alarm, and activation instrumentation and controls, distributive piping system, isolation valves, and materials and controls to limit combustibles and the associated fire loadings

  4. Fighting Fire with Fire: Surgical Options for Patients with Drug-Resistant Epilepsy.

    Science.gov (United States)

    Bayer, Alina D; Blum, Andrew S; Asaad, Wael F; Roth, Julie; Toms, Steven A; Deck, Gina M

    2018-03-01

    While antiepileptic drugs (AEDs) provide adequate seizure control for most patients with epilepsy, ~30% continue to have seizures despite treatment with two or more AEDs.1 In addition to direct harm from seizures, poor epilepsy control correlates with higher mortality, morbidity, 2, 3 and cost to the healthcare system.4 In the subset of patients with persistent seizures despite medical management, surgical intervention and neuromodulation may be more effective. Primary care physicians and general neurologists should be aware of non-AED treatment options that are standard of care for drug- resistant epilepsy (DRE). [Full article available at http://rimed.org/rimedicaljournal-2018-03.asp].

  5. Ecofriendly Fire Retardant and Rot Resistance Finishing of Jute Fabric Using Tin and Boron Based Compound

    Science.gov (United States)

    Samanta, Ashis Kumar; Bagchi, Arindam

    2017-06-01

    Treatment with sodium stannate followed by treatment with boric acid imparts jute fabric wash fast fire resistance property as indicated by its Limiting Oxygen Index (LOI) value and 45° inclined flammability test results. The treatment was carried out by impregnation of sodium stannate followed by impregnation with an aqueous solution of boric acid and drying. Application of sodium stannate (20%) and boric acid (20%) treatment on jute fabric showed balanced flame retardancy property (LOI value 34) with some loss in fabric tenacity (loss of tenacity is 14.5%). Treated fabric retained good fire retardant property after three consecutive washing. Treated fabric also possessed good rot resistance property as indicated by soil burial test and strength retention after 21 days soil burial was found to be 65%. It is found that of sodium stannate and boric acid combination by double bath process form a synergistic durable fire-retardant as well as rot resistant when impregnated on jute material, which is considerably greater than the use of either sodium stannate or boric acid alone. TGA, FTIR and SEM analysis are also reported to support the results and reaction mechanism.

  6. French position paper on sodium fires, design and testing

    International Nuclear Information System (INIS)

    Malet, J.C.; Casselman, C.; Charpenel, J.; Duverger de Cuy, G.; Rzekiecki, R.; Dufresne, J.; Lo Pinto, P.; Montaignac de; Herault, A.

    1983-01-01

    This document gives an up-to-date account of studies carried out in France in the fields of sodium fires, extinction, filtration and prefiltration of aerosols originating from a sodium fire, and of sodium concrete reactions. It also indicates how the CEA, in collaboration with the CNEN, intends to deal with scale effects. (author)

  7. Fire Related Temperature Resistance of Fly Ash Based Geopolymer Mortar

    Directory of Open Access Journals (Sweden)

    Jeyalakshmi R.

    2017-01-01

    Full Text Available The study presented in this paper is on the effect of heat treatment on fly ash based geopolymer mortar synthesized from fly ash (Class F –Low lime using alkaline binary activator solution containing sodium hydroxide (18 M and sodium silicate solution (MR 2.0, cured at 80oC for 24 h. 7 days aged specimen heated at elevated temperature (200°C, 400°C, 600°C and 800°C for the sustained period of 2hrs. The TGA/DTA analysis and thermal conductivity measurement as per ASTM C113 were carried out besides the compressive strengths. The thermal stability of the fly ash mortar at elevated temperature was found to be high as reflected in the observed value of f800°C/f30°C being more than 1 and this ratio was raised to about 1.3 with the addition of 2% Zirconium di oxide (ZrO2. No visible cracks were found on the specimens with and without ZrO2 when 800°C was sustained for 4 hrs in smaller specimens of size: 50 mm diameter x 100 mm height and in also bigger size specimens: 22 cm × 11 cm × 7 cm specimens. TGA/DTA analysis of the geopolymer paste showed that the retention of mass was around 90%. The addition of ZrO2 improved thermal resistance. The micro structure of the matrix found to be intact even at elevated temperature that was evident from the FESEM studies.

  8. Practical fire design of partially encased composite steel-concrete columns according to Eurocode 4

    Directory of Open Access Journals (Sweden)

    Sadaoui Arezki

    2014-04-01

    Full Text Available A practical method based on Campus-Massonet criteria which is developed initially to steel structures with combined compression and bending is adapted for the calculation of the buckling resistance of eccentrically loaded columns. The latter at room temperature or in fire situation is expressed by a simple formula as a function of an equivalent buckling coefficient taking into account the amount the eccentricity of the compressive applied load. The method proposed combines accuracy, efficiency and convenience obviating the need of M-N interaction diagrams and long iteration process. Otherwise, the estimation of the fire resistance for a given loading is made on the assumption based on the linearity with the level applied compressive load. It was found that the fire resistance of a column subjected to an eccentric load decreases gradually with the increase in the load level (ƞ , the slenderness ratio (λ or the amount of the eccentricity. For a fire resistance of one hour, time enough to evacuate the building of all its occupants, it recommended to use η≤ 0.5 and λ ≤45. The range of values of reinforcement cover (u suggested by Eurocode 4 leads to a better fire resistance except for u = 60 mm where there is a decline of the about 10%.

  9. The novel silicon-containing epoxy/PEPA phosphate flame retardant for transparent intumescent fire resistant coating

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Yanchao [School of Materials Science and Engineering, Tongji University, 4800 Cao' an Road, Shanghai 201804 (China); Wang, Guojian, E-mail: wanggj@tongji.edu.cn [School of Materials Science and Engineering, Tongji University, 4800 Cao' an Road, Shanghai 201804 (China); Key Laboratory of Advanced Civil Engineering Materials, Ministry of Education, 4800 Cao' an Road, Shanghai 201804 (China)

    2016-11-01

    Highlights: • The novel halogen-free flame retardant containing silicon and caged bicyclic phosphate was synthesized. • A novel transparent intumescent fire resistant coating was developed by the P-Si synergistic flame retardant and melamine formaldehyde resin. • Excellent fire protection of the transparent intumescent fire resistant coating. • The P-Si synergistic flame retardant could improve the thermo-oxidation resistance of transparent fire resistant coating. - Abstract: A series of novel silicon-containing epoxy/PEPA phosphate flame retardants (EPPSi) were synthesized by polyphosphoric acid (PPA), caged bicyclic phosphate 1-oxo-4-hydroxymethyl-2,6,7-trioxa-L-phosphabicyclo [2.2.2] octane (PEPA), and different ratios of silicon-containing epoxy 1,1,3,3-tetramethyl-1,3-bis(3-(oxiran-2-ylmethoxy)propyl)disiloxane (TMSEP) to 1,4-butanediol diglycidyl ether (BDE). The chemical structure of EPPSi was confirmed by Fourier transform infrared spectroscopy (FTIR) and {sup 1}H nuclear magnetic resonance spectroscopy ({sup 1}H NMR). Afterwards, the transparent intumescent fire resistant coatings were prepared by mixing EPPSi and melamine formaldehyde resin. The influence of silicon on the fire protection of coatings was intensively investigated by fire protection test, intumescence ratio, scanning electron microscope (SEM), compressive strength test, X-ray photoelectron spectroscopy (XPS), thermogravimetric analysis (TGA) and real-time FTIR. It was found that the fire resistant coatings obtained the best fire protection when the ratio of TMESP/BDE was 20/100, while excessive TMSEP made the fire protection of coatings deceased sharply. The intumescence ratio, compressive strength test and SEM result showed that a synergistic effect existed between phosphorus and silicon, which improved the foam structure and compressive strength of the char layer significantly. XPS result proved the out-migration effect of silicon. The high concentration silicon on surface played

  10. Selection and use of fire-resistant hydraulic fluids for underground mining equipment. [Oil-in-water emulsions; water-in-oil emulsions; phosphate esters; chlorinated hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, A J

    1981-02-01

    During the initial introduction of fire-resistant fluids to the Canadian underground mining industry, all hydraulic systems for which they were being considered were originally designed for operation with mineral oil. This meant that each system had to be individually examined and assessed with regard to its suitability in terms of acceptable component life and operation, at the same time as the selection of a fluid was being undertaken. Fluid selection by cost differential, toxicity content and fire resistancy was narrowed to types HFB and HFC, with HFB water-in-oil emulsion being the preferred fluid based on performance characteristics. By incorporating British mining industry experience and superior fluid types with practical trials, it was found that by modifing the design of some systems and slightly derating the operational parameters of individual components, it was possible to obtain a system performance comparable to that obtained when mineral oil was being used.

  11. A study on fire design accidental loads for aluminum safety helidecks

    Directory of Open Access Journals (Sweden)

    Sang Jin Kim

    2016-11-01

    Full Text Available The helideck structure must satisfy the safety requirements associated with various environmental and accidental loads. Especially, there have been a number of fire accidents offshore due to helicopter collision (take-off and/or landing in recent decades. To prevent further accidents, a substantial amount of effort has been directed toward the management of fire in the safety design of offshore helidecks. The aims of this study are to introduce and apply a procedure for quantitative risk assessment and management of fires by defining the fire loads with an applied example. The frequency of helicopter accidents are considered, and design accidental levels are applied. The proposed procedures for determining design fire loads can be efficiently applied in offshore helideck development projects.

  12. Analysis of Architectural Building Design Influences on Fire Spread in Densely Urban Settlement using Cellular Automata

    Science.gov (United States)

    Tambunan, L.; Salamah, H.; Asriana, N.

    2017-03-01

    This study aims to determine the influence of architectural design on the risk of fire spread in densely urban settlement area. Cellular Automata (CA) is used to analyse the fire spread pattern, speed, and the extent of damage. Four cells represent buildings, streets, and fields characteristic in the simulated area, as well as their flammability level and fire spread capabilities. Two fire scenarios are used to model the spread of fire: (1) fire origin in a building with concrete and wood material majority, and (2) fire origin in building with wood material majority. Building shape, building distance, road width, and total area of wall openings are considered constant, while wind is ignored. The result shows that fire spread faster in the building area with wood majority than with concrete majority. Significant amount of combustible building material, absence of distance between buildings, narrow streets and limited fields are factors which influence fire spread speed and pattern as well as extent of damage when fire occurs in the densely urban settlement area.

  13. Assessment of the fire resistance of a nuclear power plant subjected to a large commercial aircraft crash

    International Nuclear Information System (INIS)

    Jeon, Se-Jin; Jin, Byeong-Moo; Kim, Young-Jin

    2012-01-01

    Highlights: ► A procedure to assess fire resistance of structure for aircraft crash is proposed. ► Fire scenario of containment and auxiliary building is determined for aircraft crash. ► Heat transfer and thermal stress analyses are performed to obtain section forces. ► Fire endurance time is evaluated by load–moment strength interaction diagram. - Abstract: The safety assessment of infrastructures, such as a nuclear power plant, for the crash of a large commercial aircraft has been performed worldwide after the terrorism that occurred in the U.S. on September 11, 2001. The assessment, however, has mainly focused on the techniques of impact analysis. In this study, a systematic procedure to assess the fire resistance of containment and auxiliary buildings subjected to such an aircraft crash is proposed. The intensity, duration and distribution of the fire are determined based on aircraft crash analyses and characteristics of jet fuel. A three-dimensional detailed finite element model of the containment and auxiliary buildings is established and used for heat transfer and thermal stress analyses, taking into account the material properties at an elevated temperature. Section forces can then be obtained that are based on a nonlinear stress–strain relationship. The fire resistance of the structure is assessed by comparing the fire-induced section forces with the section resistance which is evaluated using the load–moment strength interaction diagram. The study addresses the problem whereby the conventional assessment that only considers the flexural behaviour is less accurate. The assessment results support the general conclusion that the nuclear power plant structures can maintain structural integrity against external fire due to their relatively thick sections. The proposed procedure can be extensively applied to evaluate the fire endurance time of any type of structure subjected to an arbitrary fire.

  14. Application of synthetic fire-resistant oils in oil systems of turbine equipment for NPPs

    Science.gov (United States)

    Galimova, L. A.

    2017-10-01

    Results of the investigation of the synthetic fire-resistant turbine oil Fyrquel-L state in oil systems of turbosets under their operation in the equipment and oil supply facilities of nuclear power plants (NPPs) are presented. On the basis of the analysis of the operating experience, it is established that, for reliable and safe operation of the turbine equipment, at which oil systems synthetic fire-resistant oils on the phosphoric acid esters basis are used, special attention should be paid to two main factors, namely, both the guarantee of the normalized oil water content under the operation and storage and temperature regime of the operation. Methods of the acid number maintenance and reduction are shown. Results of the analysis and investigation of influence of temperature and of the variation of the qualitative state of the synthetic fair-resistant oil on its water content are reported. It is shown that the fire-resistant turbine oils are characterized by high hydrophilicity, and, in distinction to the mineral turbine oils, are capable to contain a significant amount of dissolved water, which is not extracted under the use of separation technologies. It is shown that the more degradation products are contained in oil and higher acid number, the more amount of dissolved water it is capable to retain. It is demonstrated that the organization of chemical control of the total water content of fireresistant oils with the use of the coulometric method is an important element to support the reliable operation of oil systems. It is recommended to use automatic controls of water content for organization of daily monitoring of oil state in the oil system. Recommendations and measures for improvement of oil operation on the NPP, the water content control, the use of oil cleaning plants, and the oil transfer for storage during repair works are developed.

  15. Failure analysis of fire resistant fluid (FRF piping used in hydraulic control system at oil-fired thermal power generation plant

    Directory of Open Access Journals (Sweden)

    Muhammad Akram

    2017-04-01

    Full Text Available This is a case study regarding frequent forced outages in an oil-fired power generating station due to failure of fire resistant fluid (FRF piping of material ASTM A-304. This analysis was done to find out the most probable cause of failure and to rectify the problem. Methods for finding and analyzing the cracks include nondestructive testing techniques such as visual testing (VT and dye penetrant testing (PT along with that periodic monitoring after rectification of problem. The study revealed that pitting and pit to crack transitions were formed in stainless steel piping containing high pressure (system pressure 115 bars fire resistant fluid. However, after replacement of piping the pitting and cracking reoccurred. It was observed that due to possible exposure to chlorinated moisture in surrounding environment pitting was formed which then transformed into cracks. The research work discussed in this paper illustrates the procedure used in detection of the problem and measures taken to solve the problem.

  16. Cernavoda nuclear power plant: Modifications in the fire protection measures of the CANDU 6 standard design

    International Nuclear Information System (INIS)

    Covalschi, V.

    1998-01-01

    Having as purpose the improvement of fire safety at the Cernavoda NPP - both in the prevention and the protection aspects in the case of fire - we implemented some modifications in the CANDU 6 standard design. These improvements are inspired, mainly, from two sources: the world-wide achievements in the field of fire protection techniques, introduced in nuclear power plants since the middle of 70's, when the CANDU 6 design was completed; the national practice and experience in fire protection, usually applied in industrial objectives (conventional power plants, in particular). The absence of any incident may be considered as a proof of the efficiency of the implemented fire preventing and protection measures. (author)

  17. Resistive gaseous detectors designs, performance, and perspectives

    CERN Document Server

    Abbrescia, Marcello; Peskov, Vladimir

    2018-01-01

    This first book to critically summarize the latest achievements and emerging applications within this interdisciplinary topic focuses on one of the most important types of detectors for elementary particles and photons: resistive plate chambers (RPCs). In the first part, the outstanding, international team of authors comprehensively describes and presents the features and design of single and double-layer RPCs before covering more advanced multi-layer RPCs. The second part then focuses on the application of RPCs in high energy physics, materials science, medicine and security. Throughout, the experienced authors adopt a didactic approach, with each subject presented in a simple way, increasing in complexity step by step.

  18. arXiv Radiation resistant LGAD design

    CERN Document Server

    Ferrero, M.; Boscardin, M.; Cartiglia, N.; Dalla Betta, G.F.; Galloway, Z.; Mandurrino, M.; Mazza, S.; Paternoster, G.; Ficorella, F.; Pancheri, L.; Sadrozinski, H-F W.; Sola, V.; Staiano, A.; Seiden, A.; Zhao, Y.

    In this paper, we report on the radiation resistance of 50-micron thick LGAD detectors manufactured at the Fondazione Bruno Kessler employing several different doping combinations of the gain layer. LGAD detectors with gain layer doping of Boron, Boron low-diffusion, Gallium, Carbonated Boron and Carbonated Gallium have been designed and successfully produced. These sensors have been exposed to neutron fluences up to $\\phi_n \\sim 3 \\cdot 10^{16}\\; n/cm^2$ and to proton fluences up to $\\phi_p \\sim 9\\cdot10^{15}\\; p/cm^2$ to test their radiation resistance. The experimental results show that Gallium-doped LGADs are more heavily affected by initial acceptor removal than Boron-doped LGAD, while the presence of Carbon reduces initial acceptor removal both for Gallium and Boron doping. Boron low-diffusion shows a higher radiation resistance than that of standard Boron implant, indicating a dependence of the initial acceptor removal mechanism upon the implant width. This study also demonstrates that proton irradiati...

  19. Development of new radiation resistant, fire-retardant cables. [Gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Hagiwara, Ko; Morita, Yosuke; Udagawa, Takashi (Japan Atomic Energy Research Inst., Takasaki, Gunma. Takasaki Radiation Chemistry Research Establishment); Fujimura, Shun-ichi; Oda, Eisuke

    1982-12-01

    For the cables for nuclear facilities, radiation resistance and fire-retardation are severely required. The authors took note of the fact that even in the existing cables for nuclear power plants, their mechanical properties are greatly degraded by the exposure to large dose (for example, 200 Mrad in PWR testing conditions), and attempted the improvement. They employed a new additive, bromated acenaphthylene condensate (con-BACN), which effectively gives radiation resistance and also is a good flame retarder, to be compounded to an insulation material, and examined the characteristics. In this paper, the features of con-BACN and the investigation of fire-retardant EPDM composition are described. As an initial composition, a small amount of zinc white, sulphur, stearic acid, noclac 224 (Ouchi-Shinko Chemicals, Co.), and antimony trioxide, 100 parts of tale and 45 parts of con-BACN were added to 100 parts of EPDM (propylene content 34 %, Japan Synthetic Rubber Co.). As the antiaging agent, it was decided to use phenol series No. 3 as a result of test. The fire-retardant EP rubber-composed cable was produced for trial, its insulation being fabricated, using a Furukawa's pressurized salt bath continuous vulcanizer. The tests of ..gamma..-irradiation, simulated LOCA and combustion were carried out, and the test results are reported. It was indicated that the cable resisted against high dose several times as much as 200 Mrad, and was suitable for the applications, in which the mechanical properties such as bending are required to be maintained after radiation exposure. It was also found that con-BACN was safe, and its properties of decomposition, concentration and acute toxicity were all very low.

  20. Putative resistance gene markers associated with quantitative trait loci for fire blight resistance in Malus ‘Robusta 5’ accessions

    Science.gov (United States)

    2012-01-01

    Background Breeding of fire blight resistant scions and rootstocks is a goal of several international apple breeding programs, as options are limited for management of this destructive disease caused by the bacterial pathogen Erwinia amylovora. A broad, large-effect quantitative trait locus (QTL) for fire blight resistance has been reported on linkage group 3 of Malus ‘Robusta 5’. In this study we identified markers derived from putative fire blight resistance genes associated with the QTL by integrating further genetic mapping studies with bioinformatics analysis of transcript profiling data and genome sequence databases. Results When several defined E.amylovora strains were used to inoculate three progenies from international breeding programs, all with ‘Robusta 5’ as a common parent, two distinct QTLs were detected on linkage group 3, where only one had previously been mapped. In the New Zealand ‘Malling 9’ X ‘Robusta 5’ population inoculated with E. amylovora ICMP11176, the proximal QTL co-located with SNP markers derived from a leucine-rich repeat, receptor-like protein ( MxdRLP1) and a closely linked class 3 peroxidase gene. While the QTL detected in the German ‘Idared’ X ‘Robusta 5’ population inoculated with E. amylovora strains Ea222_JKI or ICMP11176 was approximately 6 cM distal to this, directly below a SNP marker derived from a heat shock 90 family protein gene ( HSP90). In the US ‘Otawa3’ X ‘Robusta5’ population inoculated with E. amylovora strains Ea273 or E2002a, the position of the LOD score peak on linkage group 3 was dependent upon the pathogen strains used for inoculation. One of the five MxdRLP1 alleles identified in fire blight resistant and susceptible cultivars was genetically associated with resistance and used to develop a high resolution melting PCR marker. A resistance QTL detected on linkage group 7 of the US population co-located with another HSP90 gene-family member and a WRKY transcription factor

  1. Fire and heat resistant laminating resins based on maleimido substituted aromatic cyclotriphosphazene polymer

    Science.gov (United States)

    Kumar, Devendra (Inventor); Fohlen, George M. (Inventor); Parker, John A. (Inventor)

    1987-01-01

    4-Aminophenoxy cyclotriphosphazenes are reacted with maleic anhydride to produce maleamic acids which are converted to the maleimides. The maleimides are polymerized. By selection of starting materials (e.g., hexakis amino or trisaminophenoxy trisphenoxy cyclotriphosphazenes), selection of molar proportions of reactants, use of mixtures of anhydrides and use of dianhydrides as bridging groups a variety of maleimides and polymers are produced. The polymers have high limiting oxygen indices, high char yields and other useful heat and fire resistant properties making them useful as, for example, impregnants of fabrics.

  2. Study of thermal stability and degradation of fire resistant candidate polymers for aircraft interiors

    Science.gov (United States)

    Hsu, M. T. S.

    1976-01-01

    The thermochemistry of bismaleimide resins and phenolphthalein polycarbonate was studied. Both materials are fire-resistant polymers and may be suitable for aircraft interiors. The chemical composition of the polymers has been determined by nuclear magnetic resonance and infrared spectroscopy and by elemental analysis. Thermal properties of these polymers have been characterized by thermogravimetric analyses. Qualitative evaluation of the volatile products formed in pyrolysis under oxidative and non-oxidative conditions has been made using infrared spectrometry. The residues after pyrolysis were analyzed by elemental analysis. The thermal stability of composite panel and thermoplastic materials for aircraft interiors was studied by thermogravimetric analyses.

  3. The Design of a Fire Source in Scale-Model Experiments with Smoke Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Brohus, Henrik; la Cour-Harbo, H.

    2004-01-01

    The paper describes the design of a fire and a smoke source for scale-model experiments with smoke ventilation. It is only possible to work with scale-model experiments where the Reynolds number is reduced compared to full scale, and it is demonstrated that special attention to the fire source...... (heat and smoke source) may improve the possibility of obtaining Reynolds number independent solutions with a fully developed flow. The paper shows scale-model experiments for the Ofenegg tunnel case. Design of a fire source for experiments with smoke ventilation in a large room and smoke movement...

  4. Optimization of investment economic in PCI using the methodology of benefits design in analysis of the spread of fires with FDS (Fire Dynamics Simulator) in areas of nuclear fire; Optimizacion de la inversion economica en PCI mediante la metodologia de diseo prestaional en el analisis de la propagacion de incendios con FDS (Fire Dynnamics Simulator) en areas de fuego de centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Salellas, J.

    2015-07-01

    Fire simulation analysis allows knowing the evolution and spread fire in areas of interest within a NPP such as control room, cable room and multi zone comportment among others. fires are a main concern regarding safety analysis of NPP. IDOM has the capability to carry out fire simulations, taken in to account smoke control, fire spread, toxicity levels, ventilation and all physical phenomena. As a result, appropriate fire protection measures can be assessed in each scenario. CFD tools applied to fire simulations can determine with higher resolution all damages caused during the fire. Furthermore, such tools can reduce costs due to a lower impact of design modifications. (Author)

  5. Design and Realization of Ship Fire Simulation Training System Based on Unity3D

    Science.gov (United States)

    Ting, Ye; Feng, Chen; Wenqiang, Wang; Kai, Yang

    2018-01-01

    Ship fire training is a very important training to ensure the safety of the ship, but limited by the characteristics of the ship itself, it is difficult to carry out fire training on the ship. This paper proposes to introduce a virtual reality technology to build a set of ship fire simulation training system, used to improve the quality of training, reduce training costs. First, the system design ideas are elaborated, and the system architecture diagram is given. Then, the key technologies in the process of system implementation are analyzed. Finally, the system examples are built and tested.

  6. [Study on discrimination of varieties of fire resistive coating for steel structure based on near-infrared spectroscopy].

    Science.gov (United States)

    Xue, Gang; Song, Wen-qi; Li, Shu-chao

    2015-01-01

    In order to achieve the rapid identification of fire resistive coating for steel structure of different brands in circulating, a new method for the fast discrimination of varieties of fire resistive coating for steel structure by means of near infrared spectroscopy was proposed. The raster scanning near infrared spectroscopy instrument and near infrared diffuse reflectance spectroscopy were applied to collect the spectral curve of different brands of fire resistive coating for steel structure and the spectral data were preprocessed with standard normal variate transformation(standard normal variate transformation, SNV) and Norris second derivative. The principal component analysis (principal component analysis, PCA)was used to near infrared spectra for cluster analysis. The analysis results showed that the cumulate reliabilities of PC1 to PC5 were 99. 791%. The 3-dimentional plot was drawn with the scores of PC1, PC2 and PC3 X 10, which appeared to provide the best clustering of the varieties of fire resistive coating for steel structure. A total of 150 fire resistive coating samples were divided into calibration set and validation set randomly, the calibration set had 125 samples with 25 samples of each variety, and the validation set had 25 samples with 5 samples of each variety. According to the principal component scores of unknown samples, Mahalanobis distance values between each variety and unknown samples were calculated to realize the discrimination of different varieties. The qualitative analysis model for external verification of unknown samples is a 10% recognition ration. The results demonstrated that this identification method can be used as a rapid, accurate method to identify the classification of fire resistive coating for steel structure and provide technical reference for market regulation.

  7. Properties of fly ash and metakaolín based geopolymer panels under fire resistance tests

    Directory of Open Access Journals (Sweden)

    Luna-Galiano, Y.

    2015-09-01

    Full Text Available This paper presents the results of a study about the effect of fire on geopolymer paste composed of fly ashes, metakaolin and sodium silicate. 2 cm thick, 28 cm high and 18 cm wide panels were filled with the paste obtained. After 28 days of curing at 20 °C and 45% of relative humidity, different tests were carried out in the geopolymers: physico-chemical (density, water absorption, porosity, mechanical (flexural and compressive strength, fire resistance and environmental (leaching and radioactivity. The panels manufactured have been compared with other commercial panels in order to determine the recycling possibilities of fly ashes in manufacturing new fire-insulating geopolymers. The panels obtained can be utilized for the production of interior wall materials, with a good physical, mechanical, fire resistant properties without any environmental problem.Este documento presenta los resultados de un estudio sobre el efecto del fuego sobre pastas de geopolímeros compuestas de cenizas volantes, metacaolín y silicato sódico. Con la pasta obtenida se han rellenado paneles de dimensiones 2 cm de espesor, 28 cm de altura y 18 cm de ancho. Tras 28 días de curado a 20 °C y un 45% de humedad relativa, diferentes ensayos fueron realizados en los geopolímeros obtenidos: fisicoquímicos (densidad, absorción de agua, porosidad, mecánicos (resistencia a compresión y a flexión, de resistencia al fuego y medioambientales (lixiviación y radioactividad. Los paneles fabricados han sido comparados con paneles comerciales para determinar las posibilidades de reciclaje de las cenizas volantes para la fabricación de nuevos productos geopoliméricos con propiedades aislantes al fuego. Los paneles obtenidos pueden ser utilizados para la producción de paredes interiores, con buenas propiedades físicas, mecánicas y de resistencia al fuego sin ningún problema medioambiental.

  8. Evaluation of mechanical design fire brick at test section on the HeaTiNG-02

    International Nuclear Information System (INIS)

    Dedy Haryanto; Riswan Djambiar; Sagino; Edy Sumarno

    2013-01-01

    The activity was carried out due to the modification of the heating in the HeaTiNG-02 test section. Modification of the heater needs to be done to overcome the obstacles that arise as part of the test section is used. Constraint that often arises is the fall of the heating source with super khantal material when it reaches a certain temperature. To mitigate the super khantal position is initially converted into a vertical position horizontal. The change from vertical to horizontal position on super khantal cause any deformities in refractory fire brick which serves as a support super khantal. Manufacture of refractory design fire brick formation and mechanical strength evaluation performed using CATIA V5 R20 software. Evaluation of fireproof rock mechanics to be based on the mechanical properties of alumina as a refractory material of fire brick. The results of the analysis have a fire brick design stress greater than the bend strength alumina materials, so that the necessary checks before and after the experiment as well as the replacement of refractory fire brick if something is broken. Translational greatest displacement 0.453 mm at a temperature of 1575 K did not give any meaningful form. Thus the refractory fire brick design can be used as heating source support in the HeaTiNG-02 test section with checks before and after the operation. (author)

  9. Guidelines of the Design of Electropyrotechnic Firing Circuit for Unmanned Flight and Ground Test Projects

    Science.gov (United States)

    Gonzalez, Guillermo A.; Lucy, Melvin H.; Massie, Jeffrey J.

    2013-01-01

    The NASA Langley Research Center, Engineering Directorate, Electronic System Branch, is responsible for providing pyrotechnic support capabilities to Langley Research Center unmanned flight and ground test projects. These capabilities include device selection, procurement, testing, problem solving, firing system design, fabrication and testing; ground support equipment design, fabrication and testing; checkout procedures and procedure?s training to pyro technicians. This technical memorandum will serve as a guideline for the design, fabrication and testing of electropyrotechnic firing systems. The guidelines will discuss the entire process beginning with requirements definition and ending with development and execution.

  10. Improving Reliability of a fire-fighting pump set with Axiomatic Design

    Directory of Open Access Journals (Sweden)

    Arcidiacono Gabriele

    2017-01-01

    Full Text Available This paper introduces a case study featuring Axiomatic Design and Multi-Level Hierarchical model (MLH applied to redesign a fire-fighting pump set. In particular, two different design concepts are presented to be applied to the supporting frame of the system to limit a vibration problem that can arise during potential malfunctioning of the fire-fighting pump. The selection of the best design has been carried out through reliability evaluation process and through the cost of failure based on the MLH model.

  11. FREEZE-THAW AND FIRE RESISTANCE OF GEOPOLYMER MORTAR BASED ON NATURAL AND WASTE POZZOLANS

    Directory of Open Access Journals (Sweden)

    F.Nurhayat Degirmenci

    2017-12-01

    Full Text Available The purpose of this research was to investigate the resistance of pozzolan-based geopolymer mortars subjected to high temperatures and freeze-thaw cycles. Low calcium fly ash and granulated blast furnace slag as waste pozzolans and natural zeolite as a natural pozzolan were used as base materials for producing geopolymer mortar. The other purpose the research was to study the effect of alkaline activator ratio (Na₂SiO₃/NaOH on the performance of pozzolan-based geopolymer mortar specimens subjected to extreme temperatures. The influence of high temperatures on the properties of mortars was investigated at 300°C, 600°C, and 900°C. Fire and freeze-thaw and resistance of mortars were investigated in terms of visual appearance, weight loss and residual compressive strength. The minimal values of the residual compressive strength were obtained at 900°C for all mixtures. The residual compressive strength of all specimens was lower than the values obtained for specimens not subjected to any freeze-thaw resistance test, except those containing GGBS. The Na₂SiO₃/NaOH ratios of the alkaline activator solution used to prepare the geopolymer mortars have an effect on the weight losses and residual compressive strengths of the specimens subjected to high temperatures and freeze-thaw cycles. As the Na2SiO3/NaOH ratios increased, the weight and strength losses decreased.

  12. Design of 500kW grate fired test facility using CFD

    DEFF Research Database (Denmark)

    Rosendahl, Lasse Aistrup; Kær, Søren Knudsen; Jørgensen, K.

    2005-01-01

    A 500kW vibrating grate fired test facility for solid biomass fuels has been designed using numerical models including CFD. The CFD modelling has focussed on the nozzle layout and flowpatterns in the lower part of the furnace, and the results have established confidence in the chosen design...

  13. Contributions of microgravity test results to the design of spacecraft fire-safety systems

    Science.gov (United States)

    Friedman, Robert; Urban, David L.

    1993-01-01

    Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.

  14. Contributions of Microgravity Test Results to the Design of Spacecraft Fire Safety Systems

    Science.gov (United States)

    Friedman, Robert; Urban, David L.

    1993-01-01

    Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) as compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.

  15. Research on design and firing performance of Si-based detonator

    Directory of Open Access Journals (Sweden)

    Rui-zhen Xie

    2014-03-01

    Full Text Available For the chip integration of MEMS (micro-electromechanical system safety and arming device, a miniature detonator needs to be developed to reduce the weight and volume of explosive train. A Si-based micro-detonator is designed and fabricated, which meets the requirement of MEMS safety and arming device. The firing sensitivity of micro-detonator is tested according to GJB/z377A-94 sensitivity test methods: Langlie. The function time of micro-detonator is measured using wire probe and photoelectric transducer. The result shows the average firing voltage is 6.4 V when the discharge capacitance of firing electro-circuit is 33 μF. And the average function time is 5.48 μs. The firing energy actually utilized by Si-based micro-detonator is explored.

  16. Resistance to fire of walls constituted by hollow blocks: Experiments and thermal modeling

    International Nuclear Information System (INIS)

    Al Nahhas, F.; Ami Saada, R.; Bonnet, G.; Delmotte, P.

    2007-01-01

    The thermo-mechanical behavior of masonry walls is investigated from both experimental and theoretical points of view. Fire tests have been performed in order to evaluate the thermo-mechanical resistance of masonry wall submitted to a vertical load (13 ton/m) and exposed to temperatures ranging from 20 to 1200 o C. As a result we measure the temperature evolution inside the wall and evaluate the vertical and lateral displacements of this wall during heating for a period of 6 h. These results are affected significantly by phase-change phenomena which appeared as a plateau around o C in temperature-time curves. A theoretical model was then developed to describe the experimental results taking in to account convection, conduction and radiation phenomena inside the wall. In addition, liquid water migration using an enthalpic method is considered

  17. Fire protection considerations in the design of plutonium handling and storage facility

    International Nuclear Information System (INIS)

    Blanchard, A.

    2000-01-01

    Unwanted fire in a facility that handles plutonium must be addressed early in the facility design. Such fires have the potential for transporting radioactive contamination throughout the building and widespread downwind dispersal. Features that mitigate such events can be severely challenged during the fire. High temperatures can cause storage containers to burst; a very efficient dispersal mechanism for radioactive contamination. The fire will also establish ventilation patterns that cause the migration of smoke and radioactive contamination throughout the facility. The smoke and soot generated by the fire will enter the exhaust system and travel to the filtration system where it will deposit on the filters. The quantity of smoke generated during a typical multi-room fire is expected to blind most High Efficiency Particulate Airfilter (HEPA) media. The blinding can have two possible outcomes. (1) The air movement though the facility is reduced, compromising the negative pressure containment and allowing contamination to leave the building though doors and other openings; or (2) the filters collapse allowing the contamination to bypass the filtration media and exit the building through the filter plenum. HEPA filter blinding during severe fires can be prevented or mitigated. Increasing the face surface area of HEPA filters will increase the smoke filtration capacity of the system, thus preventing blinding. As an alternative sandfilters can be provided to mitigate the effects of the HEPA filter bypass. Both concepts have distinct advantages. This paper will explore these two design concepts and two others; it will describe the design requirements necessary for each concept to prevent unacceptable contamination spread. The intent is to allow the filter media selection to be based on a comprehensive understanding of the four different design concepts

  18. Fire-resistance, physical, and mechanical characterization of particleboard containing Oceanic Posidonia waste

    Directory of Open Access Journals (Sweden)

    Saval, J. M.

    2014-06-01

    Full Text Available In this work, particleboards manufactured with Oceanic Posidonia waste and bonded with cement are investigated. The particleboards are made with 3/1.5/0.5 parts of cement per part of Posidonia waste. The physical properties of bulk density, swelling, surface absorption, and dimensional changes due to relative humidity as well as the mechanical properties of modulus of elasticity, bending strength, surface soundness, perpendicular tensile strength and impact resistance are studied. In terms of the above properties, the best results were obtained for particleboards with high cement content and when the waste “leaves” are treated (crushed before board fabrication, due to internal changes to the board structure under these conditions. Based on the results of fire tests, the particleboard is non-flammable without any fire-resistant treatment.En esta investigación se han diseñado y fabricado tableros con residuo de Posidonia Oceánica y cemento. Los tableros se han fabricado con 3/1.5/0.5 partes de cemento por cada parte de Posidonia estudiándose sus propiedades físicas (densidad, hinchazón, absorción superficial, variaciones dimensionales por humedad y mecánicas (módulo de elasticidad, resistencia a flexión, al arranque de superficie, al arranque de tornillo, a la tracción perpendicular y al choque. Se observa una mejora de los resultados de resistencia mecánica con el incremento de la cantidad de cemento y si la hoja del residuo es previamente tratada ya que proporciona una mejor estructura interna en el tablero. Además, tras los ensayos de reacción al fuego, se observa que el material es no inflamable sin ningún tipo de tratamiento ignifugante.

  19. FireProt: web server for automated design of thermostable proteins

    Science.gov (United States)

    Musil, Milos; Stourac, Jan; Brezovsky, Jan; Prokop, Zbynek; Zendulka, Jaroslav; Martinek, Tomas

    2017-01-01

    Abstract There is a continuous interest in increasing proteins stability to enhance their usability in numerous biomedical and biotechnological applications. A number of in silico tools for the prediction of the effect of mutations on protein stability have been developed recently. However, only single-point mutations with a small effect on protein stability are typically predicted with the existing tools and have to be followed by laborious protein expression, purification, and characterization. Here, we present FireProt, a web server for the automated design of multiple-point thermostable mutant proteins that combines structural and evolutionary information in its calculation core. FireProt utilizes sixteen tools and three protein engineering strategies for making reliable protein designs. The server is complemented with interactive, easy-to-use interface that allows users to directly analyze and optionally modify designed thermostable mutants. FireProt is freely available at http://loschmidt.chemi.muni.cz/fireprot. PMID:28449074

  20. Design and fabrication of a 50 MWt prototypical MHD coal-fired combustor

    International Nuclear Information System (INIS)

    Albright, J.; Braswell, R.; Listvinsky, G.; McAllister, M.; Myrick, S.; Ono, D.; Thom, H.

    1992-01-01

    A prototypical 50 MWt coal-fired combustor has been designed and fabricated as part of the Magnetohydrodynamic (MHD) Integrated Topping Cycle (ITC) Program. This is a DOE-funded program to develop a prototypical MHD power train to be tested at the Component Development and Integration Facility (CDIF) in Butte, Montana. The prototypical combustor is an outgrowth of the 50 MWt workhorse combustor which has previously been tested at the CDIF. In addition to meeting established performance criteria of the existing 50 MWt workhorse combustor, the prototypical combustor design is required to be scaleable for use at the 250 MWt retrofit level. This paper presents an overview of the mechanical design of the prototypical combustor and a description of its fabrication. Fabrication of the 50 MWt prototypical coal-fired combustor was completed in February 1992 and hot-fire testing is scheduled to begin in May 1992

  1. Alkali resistant Cu/zeolite deNOx catalysts for flue gas cleaning in biomass fired applications

    DEFF Research Database (Denmark)

    Putluru, Siva Sankar Reddy; Riisager, Anders; Fehrmann, Rasmus

    2011-01-01

    to investigate the redox and acidic properties of the catalysts. The poisoning resistivity seems to be due to a combination of high surface area and strong acidity of the Cu/zeolite catalysts. The catalysts might be attractive alternatives to conventional catalysts for deNOx of flue gases from biomass fired...... power plants and other stationary industrial installations....

  2. Study of fire-resistance of reinforced concrete slab of a new type

    Directory of Open Access Journals (Sweden)

    Kalmykov Oleg

    2017-01-01

    Full Text Available Reinforced concrete structures with complex inner geometry under the effect of high temperatures considering void former materials were examined. The analysis of strain-stress state of new type of architectural and construction system ‘Monofant’ under the effect of high temperature heating in standard fire mode, considering the change of design pattern was carried out. Numerical study of concrete slab with given reinforcement and complex inner geometry was carried out with use of software packages based on finite element method. Temperature fields throughout the depth of cross section of the slab of new type of architectural and construction system ‘Monofant’ upon heating in standard fire mode for time interval 0-240 min. were obtained. The carrying capacity of sections exposed to high temperatures was determined by deformation method. Offered the algorithm that considers the transformation of design patterns depending on temperature values and excessive pressure in thermal insulation cavities taking into account influence of deformation fields on temperature distribution.

  3. Design and fabrication of heat resistant multilayers

    International Nuclear Information System (INIS)

    Thorne, J.M.; Knight, L.V.; Peterson, B.G.; Perkins, R.T.; Gray, K.J.

    1986-01-01

    Many promising applications of multilayer x-ray optical elements subject them to intense radiation. This paper discusses the selection of optimal pairs of materials to resist heat damage and presents simulations of multilayer performance under extreme heat loadings

  4. Advanced fire-resistant forms of activated carbon and methods of adsorbing and separating gases using same

    Science.gov (United States)

    Xiong, Yongliang; Wang, Yifeng

    2015-02-03

    Advanced, fire-resistant activated carbon compositions useful in adsorbing gases; and having vastly improved fire resistance are provided, and methods for synthesizing the compositions are also provided. The advanced compositions have high gas adsorption capacities and rapid adsorption kinetics (comparable to commercially-available activated carbon), without having any intrinsic fire hazard. They also have superior performance to Mordenites in both adsorption capacities and kinetics. In addition, the advanced compositions do not pose the fibrous inhalation hazard that exists with use of Mordenites. The fire-resistant compositions combine activated carbon mixed with one or more hydrated and/or carbonate-containing minerals that release H.sub.2O and/or CO.sub.2 when heated. This effect raises the spontaneous ignition temperature to over 500.degree. C. in most examples, and over 800.degree. C. in some examples. Also provided are methods for removing and/or separating target gases, such as Krypton or Argon, from a gas stream by using such advanced activated carbons.

  5. Flexural behaviour of partially bonded carbon fibre reinforced polymers strengthened concrete beams: Application to fire protection systems design

    International Nuclear Information System (INIS)

    Firmo, J.P.; Arruda, M.R.T.; Correia, J.R.; Tiago, C.

    2015-01-01

    Highlights: • The mechanical behaviour of partially bonded CFRP strengthened beams was modelled. • Two dimensional non-linear finite element models were developed. • Partially bonded beams can present similar flexural strength to fully bonded ones. • Relations between the bonded length and the strength reduction were proposed. • The proposed relations were used for the design of fire protection systems. - Abstract: Recent fire resistance tests on reinforced concrete (RC) beams strengthened with carbon fibre reinforced polymers (CFRP) laminates showed that it is possible to attain considerable fire endurance provided that thermal insulation is applied at the anchorage zones of the strengthening system. With such protection, although the CFRP laminate prematurely debonds in the central part of the beam, it transforms into a cable fixed at the extremities until one of the anchorage zones loses its bond strength. The main objective of this paper is to propose a simplified methodology for the design of fire protection systems for CFRP strengthened-RC beams, which is based on applying thicker insulation at the anchorage zones (promoting the above mentioned “cable behaviour”) and a thinner one at the current zone (avoiding tensile rupture of the carbon fibres). As a first step towards the validation of this methodology, finite element (FE) models were developed to simulate the flexural behaviour at ambient temperature of full-scale RC beams strengthened with CFRP laminates according to the externally bonded reinforcement (EBR) and near surface mounted (NSM) techniques, in both cases fully or partially bonded (the latter simulating the cable). The FE models were calibrated with results of 4-point bending tests on small-scale beams and then extended for different beam geometries, with spans (L) varying from 2 m to 5 m, in which the influence of the CFRP bonded length (l b ) and the loading type (point or uniformly distributed) on the strength reduction was

  6. Different approaches of European regulations for fire design of steel structural elements

    DEFF Research Database (Denmark)

    Giuliani, Luisa; Budny, Iwona

    2010-01-01

    how both safety issues (avoid people injuries and preserve integrity of constructions) are addressed in the framework of European structural fire safety design of steel constructions. Some relevant differences can be found both in the procedures and in the philosophy of national and community...

  7. Protection against internal fires and explosions in the design of nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2004-01-01

    Experience of the past two decades in the operation of nuclear power plants and modern analysis techniques confirm that fire may be a real threat to nuclear safety and should receive adequate attention from the beginning of the design process throughout the life of the plant. Within the framework of the NUSS programme, a Safety Guide on fire protection had therefore been developed to enlarge on the general requirements given in the Code. Since its first publication in 1979, there has been considerable development in protection technology and analysis methods and after the Chernobyl accident it was decided to revise the existing Guide. This Safety Guide supplements the requirements established in Safety of Nuclear Power Plants: Design. It supersedes Safety Series No. 50-SG-D2 (Rev. 1), Fire Protection in Nuclear Power Plants: A Safety Guide, issued in 1992.The present Safety Guide is intended to advise designers, safety assessors and regulators on the concept of fire protection in the design of nuclear power plants and on recommended ways of implementing the concept in some detail in practice

  8. Design and performance of a skid-mounted portable compartment fire gas furnace and monitoring system

    Directory of Open Access Journals (Sweden)

    Mueller K.

    2013-09-01

    Full Text Available A custom, portable natural gas fire furnace was designed and constructed for use at the University of Notre Dame to experimentally investigate the out-of-plane behavior of full-scale reinforced concrete (RC bearing walls under fire. The unique aspects of this furnace allowed the application of large mechanical loads and non-contact optical response monitoring to be done while subjecting the wall to elevated temperatures. The performance of the experimental furnace, mechanical loading, and response monitoring system is reported using the results from the first two RC wall test specimens.

  9. Fire protection requirements of the insurance industry and their impact on nuclear power plant design and construction

    International Nuclear Information System (INIS)

    Deitchman, J.V.; King, W.T. Jr.; Nashman, T.A.

    1976-01-01

    The insurance industry, with its wealth of knowledge and experience in the fire protection area and with preservation of its funds at stake, has always been heavily involved in the fire protection programs of nuclear power plants. Since it was concerned with property preservation in addition to nuclear safety, the insurance industry placed more detailed emphasis on fire protection requirements than did the nuclear regulatory bodies. Since the Browns Ferry fire, however, the insurance industry, the Nuclear Regulatory Commission, the Advisory Committee on Reactor Safeguards and the utilities themselves have re-examined their approaches to fire protection. A more coordinated approach seems to have emerged, which is based largely upon insurance industry specifications and guidelines. The paper briefly summarizes the fire protection requirements of the insurance industry as they apply to nuclear power plants. Some of the ways these requirements affect project planning, plant design, and construction timing are reviewed, as well as some of the more controversial fire protection areas

  10. Overview of internal fire hazards aspects of ABWR design for United Kingdom

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kawai, Hiroki [Hitachi-GE Nuclear Energy, Ltd., Ibaraki (Japan)

    2015-12-15

    The ABWR (Advanced Boiling Water Reactor) is a generation III+ reactor, the most modern operational generation of nuclear power plants. The UK ABWR design is proposed for development and construction in the United Kingdom (UK), and under review by the Office for Nuclear Regulation (ONR) through Generic Design Assessment (GDA). The UK ABWR design has mainly two types of the safety system: ''preventing'' and ''mitigating'' a fault and their consequences. The prevention of internal hazards starts with design processes and procedures. These processes lead to limiting the sources of potential hazards. The mitigative safety systems are required to ensure the fundamental safety functions (FSFs): control of reactivity, Fuel cooling, long term heat removal, confinement/containment of radioactive materials, and others. Implementation of the safety philosophy is based upon redundant and diverse safety systems that deliver the FSFs. Three mechanical divisions are provided, each of which contains redundant systems, structures, and components (SSCs) capable of carrying out all the FSFs. The safety divisions are separated by robust barriers which act to contain a hazard in an affected division and prevent the spread of the hazard to a different division. The deterministic assessments and the hazard schedule argue that the rooms containing SSCs providing the FSFs are located in different fire safety divisions. The approach to maintaining the FSFs during and after internal fires is to ensure fires do not spread beyond that division to affect redundant equipment in other divisions. During the GDA process, it is demonstrated that generally barrier compartmentation (the divisional barrier walls, ceilings and floors) is sufficient to contain the postulated fires. The UK ABWR design has sufficient capability of withstanding the postulated internal fire hazard to achieve the FSFs. Further development is being undertaken with feedback in the GDA

  11. Design of an actively cooled plate calorimeter for the investigation of pool fire heat fluxes

    International Nuclear Information System (INIS)

    Koski, J.A.; Keltner, N.R.; Nicolette, V.F.; Wix, S.D.

    1992-01-01

    For final qualification of shipping containers for transport of hazardous materials, thermal testing in accordance with regulations such as 10CFR71 must be completed. Such tests typically consist of 30 minute exposures with the container fully engulfed in flames from a large, open pool of JP4 jet engine fuel. Despite careful engineering analyses of the container, testing often reveals design problems that must be solved by modification and expensive retesting of the container. One source of this problem is the wide variation in surface heat flux to the container that occurs in pool fires. Average beat fluxes of 50 to 60 kW/m 2 are typical and close the values implied by the radiation model in 10CFR71, but peak fluxes up to 150 kW/m 2 are routinely observed in fires (Keltner, et al,1990). Heat fluxes in pool fires have been shown to be a function of surface temperature of the container, height above the pool, surface orientation, wind, and other variables. If local variations in the surface heat flux to the container can be better predicted, design analyses will become more accurate, and fewer problems will be uncovered during testing. The objective of the calorimeter design described in this paper is to measure accurately pool fire heat fluxes under controlled conditions, and to provide data for calibration of improved analytical models of local flame-surface interactions

  12. Design of an actively cooled plate calorimeter for the investigation of pool fire heat fluxes

    International Nuclear Information System (INIS)

    Koski, J.A.; Keltner, N.R.; Nicolette, V.F.; Wix, S.D.

    1992-01-01

    For final qualification of shipping containers for transport of hazardous materials, thermal testing in accordance with regulations such as 10CFR71 must be completed. Such tests typically consist of 30 minute exposures with the container fully engulfed in flames from a large, open pool of JP4 jet engine fuel. Despite careful engineering analyses of the container, testing often reveals design problems that must be solved by modification and expensive retesting of the container. One source of this problem is the wide variation in surface heat flux to the container that occurs in pool fires. Average heat fluxes of 50 to 60 kW/m 2 are typical and close the values implied by the radiation model in 10CFR71, but peak fluxes up to 150 kW/m 2 are routinely observed in fires. Heat fluxes in pool fires have been shown to be a function of surface temperature of the container, height above the pool, surface orientation, wind, and other variables. If local variations in the surface heat flux to the container could be better predicted, design analyses would become more accurate, and fewer problems will be uncovered during testing. The objective of the calorimeter design described in this paper is to measure accurately pool fire heat fluxes under controlled conditions, and to provide data for calibration of improved analytical models of local flame-surface interactions

  13. Design and analysis of the federal aviation administration next generation fire test burner

    Science.gov (United States)

    Ochs, Robert Ian

    The United States Federal Aviation Administration makes use of threat-based fire test methods for the certification of aircraft cabin materials to enhance the level of safety in the event of an in-flight or post-crash fire on a transport airplane. The global nature of the aviation industry results in these test methods being performed at hundreds of laboratories around the world; in some cases testing identical materials at multiple labs but yielding different results. Maintenance of this standard for an elevated level of safety requires that the test methods be as well defined as possible, necessitating a comprehensive understanding of critical test method parameters. The tests have evolved from simple Bunsen burner material tests to larger, more complicated apparatuses, requiring greater understanding of the device for proper application. The FAA specifies a modified home heating oil burner to simulate the effects of large, intense fires for testing of aircraft seat cushions, cargo compartment liners, power plant components, and thermal acoustic insulation. Recently, the FAA has developed a Next Generation (NexGen) Fire Test burner to replace the original oil burner that has become commercially unavailable. The NexGen burner design is based on the original oil burner but with more precise control of the air and fuel flow rates with the addition of a sonic nozzle and a pressurized fuel system. Knowledge of the fundamental flow properties created by various burner configurations is desired to develop an updated and standardized burner configuration for use around the world for aircraft materials fire testing and airplane certification. To that end, the NexGen fire test burner was analyzed with Particle Image Velocimetry (PIV) to resolve the non-reacting exit flow field and determine the influence of the configuration of burner components. The correlation between the measured flow fields and the standard burner performance metrics of flame temperature and

  14. Guide design study for the high-resolution backscattering spectrometer FIRES

    Energy Technology Data Exchange (ETDEWEB)

    Pelley, C; Kargl, F; Sakai, V Garcia; Telling, M T F; Fernandez-Alonso, F; Demmel, F, E-mail: franz.demmel@stfc.ac.uk

    2010-11-01

    Different options are considered to transport cold neutrons along 90 m for the proposed new spectrometer FIRES at the ISIS facility. Monte Carlo simulations using the McStas programme package are used to assess the performance of various guide designs from the biological shield to the sample position. By employing a curved geometry, to avoid the direct line of sight, a hybrid design which combines a curved ballistic guide and an elliptic focusing section appears to be the best solution.

  15. Fire Protection Engineering Design Brief Template. Hydrogen Refueling Station.

    Energy Technology Data Exchange (ETDEWEB)

    LaFleur, Angela Christine [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Muna, Alice Baca [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Groth, Katrina M. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-08-01

    Building a hydrogen infrastructure system is critical to supporting the development of alternate- fuel vehicles. This report provides a methodology for implementing a performance-based design of an outdoor hydrogen refueling station that does not meet specific prescriptive requirements in NFPA 2, The Hydrogen Technologies Code . Performance-based designs are a code-compliant alternative to meeting prescriptive requirements. Compliance is demonstrated by comparing a prescriptive-based fueling station design with a performance-based design approach using Quantitative Risk Assessment (QRA) methods and hydrogen risk assessment tools. This template utilizes the Sandia-developed QRA tool, Hydrogen Risk Analysis Models (HyRAM), which combines reduced-order deterministic models that characterize hydrogen release and flame behavior with probabilistic risk models to quantify risk values. Each project is unique and this template is not intended to account for site-specific characteristics. Instead, example content and a methodology are provided for a representative hydrogen refueling site which can be built upon for new hydrogen applications.

  16. Ultralight and fire-resistant ceramic nanofibrous aerogels with temperature-invariant superelasticity.

    Science.gov (United States)

    Si, Yang; Wang, Xueqin; Dou, Lvye; Yu, Jianyong; Ding, Bin

    2018-04-01

    Ultralight aerogels that are both highly resilient and compressible have been fabricated from various materials including polymer, carbon, and metal. However, it has remained a great challenge to realize high elasticity in aerogels solely based on ceramic components. We report a scalable strategy to create superelastic lamellar-structured ceramic nanofibrous aerogels (CNFAs) by combining SiO 2 nanofibers with aluminoborosilicate matrices. This approach causes the random-deposited SiO 2 nanofibers to assemble into elastic ceramic aerogels with tunable densities and desired shapes on a large scale. The resulting CNFAs exhibit the integrated properties of flyweight densities of >0.15 mg cm -3 , rapid recovery from 80% strain, zero Poisson's ratio, and temperature-invariant superelasticity to 1100°C. The integral ceramic nature also provided the CNFAs with robust fire resistance and thermal insulation performance. The successful synthesis of these fascinating materials may provide new insights into the development of ceramics in a lightweight, resilient, and structurally adaptive form.

  17. Proposal for the award of a blanket purchase contract for the design, supply, installation and maintenance of automatic fire-detection, fire-protection and voice-alarm systems for the Super Proton Synchrotron

    CERN Document Server

    2017-01-01

    Proposal for the award of a blanket purchase contract for the design, supply, installation and maintenance of automatic fire-detection, fire-protection and voice-alarm systems for the Super Proton Synchrotron

  18. Fire and grazing influence site resistance to Bromus tectorum through their effects on shrub, bunchgrass and biocrust communities in the Great Basin (USA)

    Science.gov (United States)

    Condon, Lea A.; Pyke, David A.

    2018-01-01

    Shrubs, bunchgrasses and biological soil crusts (biocrusts) are believed to contribute to site resistance to plant invasions in the presence of cattle grazing. Although fire is a concomitant disturbance with grazing, little is known regarding their combined impacts on invasion resistance. We are the first to date to test the idea that biotic communities mediate the effects of disturbance on site resistance. We assessed cover of Bromus tectorum, shrubs, native bunchgrasses, lichens and mosses in 99 burned and unburned plots located on similar soils where fires occurred between 12 and 23 years before sampling. Structural equation modeling was used to test hypothesized relationships between environmental and disturbance characteristics, the biotic community and resistance to B. tectorum cover. Characteristics of fire and grazing did not directly relate to cover of B. tectorum. Relationships were mediated through shrub, bunchgrass and biocrust communities. Increased site resistance following fire was associated with higher bunchgrass cover and recovery of bunchgrasses and mosses with time since fire. Evidence of grazing was more pronounced on burned sites and was positively correlated with the cover of B. tectorum, indicating an interaction between fire and grazing that decreases site resistance. Lichen cover showed a weak, negative relationship with cover of B. tectorum. Fire reduced near-term site resistance to B. tectorum on actively grazed rangelands. Independent of fire, grazing impacts resulted in reduced site resistance to B. tectorum, suggesting that grazing management that enhances plant and biocrust communities will also enhance site resistance.

  19. Unites States position paper on sodium fires. Design basis and testing

    International Nuclear Information System (INIS)

    Lancet, R.T.; Johnson, R.P.; Matlin, E.; Vaughan, E.U.; Fields, D.E.; Glueckler, E.; McCormack, J.D.; Miller, C.W.; Pedersen, D.R.

    1989-01-01

    This paper focuses on designs, analyses, and tests performed since the last Sodium Fires Meeting of the IAEA International Working Group on Fast Reactors in May 1982. Since the U.S. Liquid Metal Reactor (LMR) program is focused on the two advanced LMRs, SAFR and PRISM, the paper relates this work to these designs. First, the design philosophy and approach taken by these advanced pool reactors are described. This includes methods of leak detection, the design basis leaks, and passive accommodation of sodium fires. Then the small- and large-scale sodium fire tests performed in support of the Clinch River Breeder Reactor Plant (CRBRP) program, including post-accident cleanup, are presented and related to the advanced LMR designs. Next, the assessment and behavior of the aerosols generated are discussed including generation rate, behavior within structures, release and dispersal, and deposition on safety-grade equipment. Finally, the impact of these aerosols on the performance of safety-grade decay heat removal heat exchange surfaces is discussed including some test results as well as planned tests. (author)

  20. Design and construction of a resistivity meter for shallow investigation

    African Journals Online (AJOL)

    Design and construction of a resistivity meter for shallow investigation. ... Nigerian Journal of Physics. Journal Home ... Consequently many institutions that need this equipment for teaching and research purposes cannot afford the price.

  1. Recent operating experience in Europe and the Soviet Union with fire resistant turbine lubricants

    International Nuclear Information System (INIS)

    Vilyanskaya, G.D.; Lysko, V.V.; Phillips, W.D.

    1990-01-01

    Power station fires are of continuing concern to the electricity generation industry. Statistics on their frequency and severity are however difficult to obtain and it is suspected that many fires are not officially reported unless they result in a forced outage or casualties are involved. It is well known that fires in power stations can be extremely expensive incidents. Not only is the cost of repairing equipment very high but outage costs can amount to millions of dollars. A recent publication listed the financial cost (where known) of seven major fires in the USA occurring between 1985--89. The author of the article commented that In many cases fixed fire suppression systems were non-existent, incomplete or inaccessible. The fire emergency planning proved to be generally ineffective and in some cases non-existent

  2. Evaluation of Fire Resistance for H-Section Columns Made of Rolled Steels for General Structures and for Welded Structures by Analytic Method

    International Nuclear Information System (INIS)

    Kwon, In-Kyu

    2014-01-01

    Fire resistance is an important factor in sustaining the structural stability of steel framed buildings on fire. However, evaluation of the fire resistance of steel columns has been conducted using rolled steels for general structures, SS 400. Recently, rolled steels for welded structures, such as SM 400 and SM 490, have been used frequently because they have better performance of welding than the SS 400. However, there has been doubt about how much fire resistance SM 400 and SM 490 have. To evaluate by calculation the fire resistance of an H-section column made of SS 400 its mechanical and thermal properties were derived and suggested respectively in the form of regressive equations and the analysis was done based on heat transfer and thermal stress analysis. In this study, the results of the evaluation of H-section columns made of SS 400 with loaded fire tests turned out to be conservative. As a result, a new guideline is required to get the exact fire resistance of another structural steel.

  3. Managing resistance and negotiating co-design

    DEFF Research Database (Denmark)

    Yndigegn, Signe Louise

    work. The aim was to design services for senior citizens with the focus on social interaction – and with technology as a way to support the interaction among communities of elderlies. The dissertation is a retrospective reflection of the author’s experience with taking part and being heavily involved......This dissertation is a retrospective reflection on a user-driven innovation project, Senior Interaktion. The project was a three-year long project with focus on how to design services for senior citizens and to do that with a co-design approach involving citizens and private partners in the design...... organizations. The loose set-up of the living lab and these project constellations raise questions of who is working for whom, who owns it, who is responsible - but also questions of who knows the rules and terms of conditions. The dissertation ends with a discussion of the issues raised throughout...

  4. Design of Fire/Gas Penetration Seals and fire exposure tests for Tokamak Fusion Test Reactor experimental areas

    International Nuclear Information System (INIS)

    Cavalluzzo, S.

    1983-01-01

    A Fire/Gas Penetration Seal is required in every penetration through the walls and ceilings into the Test Cell housing the Tokamak Fusion Test Reactor (TFTR), as well as other adjacent areas to protect the TFTR from fire damage. The penetrations are used for field coil lead stems, diagnostics systems, utilities, cables, trays, mechanical devices, electrical conduits, vacuum liner, air conditioning ducts, water pipes, and gas pipes. The function of the Fire/Gas Penetration Seals is to prevent the passage of fire and products of combustion through penetrations for a period of time up to three hours and remain structurally intact during fire exposure. The Penetration Seal must withstand, without rupture, a fire hose water stream directed at the hot surface. There are over 3000 penetrations ranging in size from several square inches to 100 square feet, and classified into 90 different types. The material used to construct the Fire/Gas Penetration Seals consist of a single and a two-component room temperature vulcanizing (RTV) silicone rubber compound. Miscellaneous materials such as alumina silica refractory fibers in board, blanket and fiber forms are also used in the construction and assembly of the Seals. This paper describes some of the penetration seals and the test procedures used to perform the three-hour fire exposure tests to demonstrate the adequacy of the seals

  5. A Survey of a System of Methods for Fire Safety Design of Traditional Concrete Constructions

    DEFF Research Database (Denmark)

    Hertz, Kristian

    2000-01-01

    constructions DS411. And the bases for many of the methods have been distributed by CIB W14 reports. But a survey of all the methods in coherence has never been presented, and much of this documentation and the additional documentation produced for the work with the codes needs still to be printed in papers......During the years since 1978 the author has been developing a series of calculation methods and sup-porting test methods for the fire safety design of concrete constructions. The basic methods have been adopted in the fire chapters of the Eurocode ENV1992-1-2 and the Danish code for concrete.......It is the aim of this paper to give a coherent presentation of the design methods, their degree of documentation and the available references in order to facilitate the application of them....

  6. Clinch River breeder reactor sodium fire protection system design and development

    International Nuclear Information System (INIS)

    Foster, K.W.; Boasso, C.J.; Kaushal, N.N.

    1984-01-01

    To assure the protection of the public and plant equipment, improbable accidents were hypothesized to form the basis for the design of safety systems. One such accident is the postulated failure of the Intermediate Heat Transfer System (IHTS) piping within the Steam Generator Building (SGB), resulting in a large-scale sodium fire. This paper discusses the design and development of plant features to reduce the consequences of the accident to acceptable levels. Additional design solutions were made to mitigate the sodium spray contribution to the accident scenario. Sodium spill tests demonstrated that large sodium leaks can be safely controlled in a sodium-cooled nuclear power plant

  7. Forest Management and the Evolution of Project Design in Dynamic Wildland Urban Interface Fire Environments

    Science.gov (United States)

    Conway, S.

    2014-12-01

    The Truckee Ranger District on the Tahoe National Forest, in the heart of the Sierra Nevada Mountains, has a rich history of human activities. Native American influences, comstock-era logging, fire suppression, development, and recreation have all shaped the natural environment into what it is today. Like much of our national forests in California, forest conditions that have developed are generally much more homogenous and less resistant to disturbance from fire, insect, and disease than they might have been without the myriad of human influences. However, in order to improve the resiliency of our forests to stand replacing disturbances like high severity fire, while managing for integrated anthropomorphic values, it is imperative that management evolve to meet those dynamic needs. Recent advances in remote sensing and GIS allow land managers more access to forest information and can inform site specific prescriptions to change site specific undesirable conditions. It is ecologically and politically complex, yet our forests deserve that microscope. This particular presentation will focus on how the Truckee Ranger District began this process of incorporating several values, generated from stakeholder collaboration, into one project's goals and how those lessons learned informed their most recent project.

  8. Performance and damages of R.C. slabs in fire

    DEFF Research Database (Denmark)

    Giuliani, Luisa; Gentili, Filippo

    2015-01-01

    Contrary to a common misconception, concrete structures are particularly vulnerable to fire, as witnesses by several cases of fire-induced collapses of buildings with a primary concrete structural system. Even when no collapse occurs, concrete elements are permanently damaged by the fire and may...... on the vulnerability of the slab to the fire action and can be used for optimizing the design on the basis of the required class of resistance or for choosing between different slab alternatives....

  9. Technologies for Protection and Resistance Enhancement of Critical Infrastructures againstExtreme Fire

    Science.gov (United States)

    2014-05-01

    involving hydrocarbon fires, such as gasoline or crude oil carried in a tanker truck/train, or any other fuel fire of equivalent intensity. Examples of...and impact of weather exposure on the insulation, as well as possible health risk by inhalation (mainly concern for interior application), application

  10. Considerations in designing and using superconductors with high resistivity matrices

    International Nuclear Information System (INIS)

    Bartlett, R.J.; Carlson, R.V.; Laquer, H.L.; Migliori, A.

    1976-01-01

    Superconductors are often designed with matrices of much higher residual resistivities than copper for reasons of manufacturing (multifilamentary Nb 3 Sn in CuSn bronze) or loss reduction (mixed matrix NbTi with Cu and CuNi). The high resistivity matrix may complicate or degrade contact resistances at the joints, generate excess heat, reduce the stability of the conductor, and interfere with the observation of flux flow resistivities in the 10 -12 Ω-cm region. The minimization of these effects is discussed, presenting both simple and more refined models for the current transfer length, and it is shown how variations in transfer length (with current), particularly under significant self field conditions, can mimic flux flow resistivity

  11. Fire, safety and ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Hindle, D.

    1999-02-01

    Correct ventilation in tunnel environments is vital for the comfort and safety of the people passing through. This article gives details of products from several manufacturers of safety rescue and fire fighting equipment, fire and fume detection equipment, special fire resistant materials, fire resistant hydraulic oils and fire dampers, and ventilation systems. Company addresses and fax numbers are supplied. 4 refs., 5 tabs., 10 photos.

  12. Verification of fire and explosion accident analysis codes (facility design and preliminary results)

    International Nuclear Information System (INIS)

    Gregory, W.S.; Nichols, B.D.; Talbott, D.V.; Smith, P.R.; Fenton, D.L.

    1985-01-01

    For several years, the US Nuclear Regulatory Commission has sponsored the development of methods for improving capabilities to analyze the effects of postulated accidents in nuclear facilities; the accidents of interest are those that could occur during nuclear materials handling. At the Los Alamos National Laboratory, this program has resulted in three computer codes: FIRAC, EXPAC, and TORAC. These codes are designed to predict the effects of fires, explosions, and tornadoes in nuclear facilities. Particular emphasis is placed on the movement of airborne radioactive material through the gaseous effluent treatment system of a nuclear installation. The design, construction, and calibration of an experimental ventilation system to verify the fire and explosion accident analysis codes are described. The facility features a large industrial heater and several aerosol smoke generators that are used to simulate fires. Both injected thermal energy and aerosol mass can be controlled using this equipment. Explosions are simulated with H 2 /O 2 balloons and small explosive charges. Experimental measurements of temperature, energy, aerosol release rates, smoke concentration, and mass accumulation on HEPA filters can be made. Volumetric flow rate and differential pressures also are monitored. The initial experiments involve varying parameters such as thermal and aerosol rate and ventilation flow rate. FIRAC prediction results are presented. 10 figs

  13. CONCEPTUAL DESIGN ASSESSMENT FOR THE CO-FIRING OF BIO-REFINERY SUPPLIED LIGNIN PROJECT

    International Nuclear Information System (INIS)

    Ted Berglund; Jeffrey T. Ranney; Carol L. Babb; Jacqueline G. Broder

    2001-01-01

    The major aspects of this project are proceeding toward completion. Prior to this quarter, design criteria, tentative site selection, facility layout, and preliminary facility cost estimates have been completed and issued for review. Processing of bio-solids was completed, providing material for the pilot operations. Pilot facility design, equipment selection, and modification were completed during the fourth quarter of 2000. Initial pilot facility shakedown was completed during the fourth quarter. After some unavoidable delays, a suitable representative supply of municipal solid waste (MSW) feed material was procured. During this quarter (first quarter of 2001), shredding of the feed material was completed and final feed conditioning was completed. Pilot facility hydrolysis production was completed to produce lignin for co-fire testing. Pilot facility modifications continued to improve facility operations and performance during the first quarter of 2001. Samples of the co-fire fuel material were sent to the co-fire facility for evaluation. The TVA-Colbert facility has neared completion of the task to evaluate the co-location of the Masada facility on the operation of the power generation facility. The TVA-Colbert fossil plant is fully capable of providing a reliable steam supply. The preferred steam supply connection points and steam pipeline routing have been identified. The environmental review of the pipeline routing has been completed and no major impacts have been identified. Detailed assessment of steam export impacts on the Colbert boiler system have been completed and a cost estimate for steam supply system is being developed

  14. Constructive fire protection of steel corrugated beams of buildings and other structures

    Directory of Open Access Journals (Sweden)

    Ilyin Nikolay

    2017-01-01

    Full Text Available The research introduces a methodology of establishing indicators of fire safety of a building in relation to a guaranteed duration of steel fire-proof corrugated beams resistance in conditions of standard fire tests. Indicators of fire safety are also established in the assessment of design limits of steel fire-proof corrugated beams during design process, construction or maintenance of the building as well as in reducing economic costs when testing steel structures for fire resisting property. The suggested methodology introduces the system of actions aimed to design constructive fire protection of steel corrugated beams of buildings. Technological effect is achieved by conducting firing tests of steel construction by non-destructive methods; the evaluation of fire resistance of fire-proof elements of corrugated beams (corrugated web, upper and lower shelves is identified by the least fire-proof element of a welded I-beam. In this methodology fire resistance duration of the constituent elements of a welded I-beam with account of its fire protection ability is described with an analytic function taken as variables. These variables are intensity strength of stresses and the degree of fire protection of a compound element.

  15. Conceptual designs of pressurized fluidized bed and pulverized coal fired power plants

    International Nuclear Information System (INIS)

    Doss, H.S.; Bezella, W.A.; Hamm, J.R.; Pietruszkiewicz, J.

    1984-01-01

    This paper presents the major technical and economic characteristics of steam and air-cooled pressurized fluidized bed (PFB) power plant concepts, along with the characteristics of a pulverized coal fired power plant equipped with an adipic acid enhanced wet-limestone flue gas desulfurization system. Conceptual designs for the three plants were prepared to satisfy a set of common groundrules developed for the study. Grassroots plants, located on a generic plant site were assumed. The designs incorporate technologies projected to be commercial in the 1990 time frame. Power outputs, heat rates, and costs are presented

  16. Design of an actively cooled plate calorimeter for the investigation of pool fire heat fluxes

    International Nuclear Information System (INIS)

    Koski, J.A.; Keltner, N.R.; Nicolette, V.F.; Wix, S.D.

    1993-01-01

    In order to better measure local heat fluxes in open pool fires, an actively cooled calorimeter has been designed and analyzed. As this paper is being prepared, the calorimeter is in fabrication. Following fabrication, testing in a radiant heat facility is planned to assure proper performance before introduction into the pool fire environment. Initially, testing in the SMERF facility will assure reproducibility of tests by removing wind effects. As the program progresses, tests in open facilities, and with different geometries are anticipated. Experimental data from the initial tests will be compared continuously to the gray gas model, and as experiments proceed, the gray gas analytical model will be refined with the goal of improving finite element code analysis of shipping containers. (J.P.N.)

  17. Does prescribed fire promote resistance to drought in low elevation forests of the Sierra Nevada, California, USA?

    Science.gov (United States)

    van Mantgem, Phillip J.; Caprio, Anthony C.; Stephenson, Nathan L.; Das, Adrian J.

    2016-01-01

    Prescribed fire is a primary tool used to restore western forests following more than a century of fire exclusion, reducing fire hazard by removing dead and live fuels (small trees and shrubs).  It is commonly assumed that the reduced forest density following prescribed fire also reduces competition for resources among the remaining trees, so that the remaining trees are more resistant (more likely to survive) in the face of additional stressors, such as drought.  Yet this proposition remains largely untested, so that managers do not have the basic information to evaluate whether prescribed fire may help forests adapt to a future of more frequent and severe drought.During the third year of drought, in 2014, we surveyed 9950 trees in 38 burned and 18 unburned mixed conifer forest plots at low elevation (accounting for differences in individual tree diameter, common conifer species found in the burned plots had significantly reduced probability of mortality compared to unburned plots during the drought.  Stand density (stems ha-1) was significantly lower in burned versus unburned sites, supporting the idea that reduced competition may be responsible for the differential drought mortality response.  At the time of writing, we are not sure if burned stands will maintain lower tree mortality probabilities in the face of the continued, severe drought of 2015.  Future work should aim to better identify drought response mechanisms and how these may vary across other forest types and regions, particularly in other areas experiencing severe drought in the Sierra Nevada and on the Colorado Plateau.

  18. FIRE RESISTANCE OF DOUGLAS FIR [Pseudotsuga menziesii (Mirb. Franco] WOOD TREATED WITH SOME CHEMICALS

    Directory of Open Access Journals (Sweden)

    M. Kemal YALINKILIÇ

    1998-02-01

    Full Text Available Combustible properties of treated douglas wood specimens and fire-retardancy of some preservatives were tested in this study. Crib test of ASTM E 160-150 was followed. Results indicated that, aqueous solutions of boric acid (BA, borax (Bx (Na2BO7 10H2O or BA + Bx mixture (7: 3, w: w had fire retardant efficacy (FRE over untreated wood and reduced the combustibility of vinil monomers (Styrene and methylmetacrylate which were applied as secondary treatment.

  19. ABB. CASE's GUARDIANTM Debris Resistant Fuel Assembly Design

    International Nuclear Information System (INIS)

    Dixon, D. J.; Wohlsen, W. D.

    1992-01-01

    ABB CE's experience, that 72% of all recent fuel-rod failures are caused by debris fretting, is typical. In response to this problem, ABB Combustion Engineering began supplying in the late 1980s fuel assemblies with a variety of debris resistant features, including both long-end caps and small flow holes. Now ABB CAE has developed an advanced debris resistant design concept, GUARDIAN TM , which has the advantage of capturing and retaining more debris than other designs, while displacing less plenum or active fuel volume than the long end-cap design. GUARDIAN TM design features have now been implemented into four different assembly designs. ABB CASE's GUARDIAN TM fuel assembly is an advanced debris-resistant design which has both superior filtering performance and uniquely, excellent debris retention, Retention effectively removes the debris from circulation in the coolant so that it is not able to threaten the fuel again. GUARDIAN TM features have been incorporated into four ABB. CAE fuel assembly designs. These assemblies are all fully compatible with the NSLS, and full-batch operation with GUARDIAN TM began in 1992. The number of plants of both CAE and non-CAE design which accept GUARDIAN TM for debris protection is expected to grow significantly during the next few years

  20. CONCEPTUAL DESIGN ASSESSMENT FOR THE CO-FIRING OF BIO-REFINERY SUPPLIED LIGNIN PROJECT

    International Nuclear Information System (INIS)

    Ted Berglund; Jeffrey T. Ranney; Carol L. Babb; Jacqueline G. Broder

    2002-01-01

    The major aspects of this project are proceeding toward completion. Prior to this quarter, design criteria, tentative site selection, facility layout, and preliminary facility cost estimates were completed and issued. Processing of bio-solids was completed, providing material for the pilot operations. Pilot facility hydrolysis production has been completed to produce lignin for co-fire testing and the lignin fuel was washed and dewatered. Both the lignin and bio-solids fuel materials for co-fire testing were sent to the co-fire facility (EERC) for evaluation and co-firing. EERC has received coal typical of the fuel to the TVA-Colbert boilers. This material was used at EERC as baseline material and for mixing with the bio-fuel for combustion testing. All the combustion and fuel handling tests at EERC have been completed. During fuel preparation EERC reported no difficulties in fuel blending and handling. Preliminary co-fire test results indicate that the blending of lignin and bio-solids with the Colbert coal blend generally reduces NO(sub x) emissions, increases the reactivity of the coal, and increases the ash deposition rate on superheater surfaces. Deposits produced from the fuel blends, however, are more friable and hence easier to remove from tube surfaces relative to those produced from the baseline Colbert coal blend. The final co-fire testing report is being prepared at EERC and will be completed by the end of the second quarter of 2002. The TVA-Colbert facility has neared completion of the task to evaluate co-location of the Masada facility on the operation of the power generation facility. The TVA-Colbert fossil plant is fully capable of providing a reliable steam supply. The preferred steam supply connection points and steam pipeline routing have been identified. The environmental review of the pipeline routing has been completed and no major impacts have been identified. Detailed assessment of steam export impacts on the Colbert boiler system have been

  1. Measurements and simulation for design optimization for low NOx coal-firing system

    Energy Technology Data Exchange (ETDEWEB)

    E. Bar-Ziv; Y. Yasur; B. Chudnovsky; L. Levin; A. Talanker [Ben-Gurion University of Negev, Beer-Sheva (Israel)

    2003-07-01

    The information required to design a utility steam generator is the heat balance, fuel analysis and emission. These establish the furnace wall configuration, the heat release rates, and the firing technology. The furnace must be sized for (1) residence time for complete combustion with low NOx, and (2) reduction of flue gas temperature to minimize ash deposition. To meet these, computational fluid dynamics (CFD) of the combustion process in the furnace were performed and proven to be a powerful tool for this purpose. Still, reliable numerical simulations require careful interpretation and comparison with measurements. We report numerical results and measurements for a 575 MW pulverized coal tangential firing boiler of the Hadera power plant of Israel Electric Corporation (IEC). Measured and calculated values were found to be in reasonable agreement. We used the simulations for optimization and investigated temperature distribution, heat fluxes and concentration of chemical species. We optimized both the furnace flue gas temperature entering the convective path and the staged residence time for low NOx. We tested mass flow rates through close-coupled and separate overfire air ports and its arrangement and the coal powder fineness. These parameters can control the mixing rate between the fuel and the oxidizer streams and can affect the most important characteristics of the boiler such as temperature regimes, coal burning rate and nitrogen oxidation/reduction. From this effort, IEC started to improve the boiler performance by replacing the existing typical tangential burners to low NOx firing system to ensure the current regulation requirements of emission pollutions.

  2. Assessment of nitrogen oxide emission for designing boilers fired with coal dust

    Energy Technology Data Exchange (ETDEWEB)

    Kotler, V.R.; Gusev, L.N.; Babii, V.I.

    1983-09-01

    A method for forecasting emission of nitrogen oxides from steam boilers fired with coal is described. The method produces accurate results when nitrogen oxide emission from furnaces with straight-flow burners and turbulent-type burners fired with coal dusts is forecast. Oxides formed by decomposition of chemical compounds in coal (so-called 'fuel' nitrogen oxides) and nitrogen oxides formed by oxidation of molecular nitrogen by atomic oxygen (so-called 'thermal' nitrogen oxides) are evaluated. Zones in which the two types of nitrogen oxide are formed in flames are characterized. Factors which influence formation of nitrogen oxides in a furnace are evaluated: excess air, flue gas recirculation, design of a furnace and burners, movement of air and coal dust mixture in a furnace, temperature, methods for coal dust preparation, coal dust properties. Equations for forecasting emission of nitrogen oxides from furnaces are derived. Nomograms for easy calculation of emission are also given. Examples of using the method for forecasting emission of nitrogen oxides from furnaces fired with coal from the Kuzbass, the Donbass and Ehkibastuz are discussed. Comparisons of emission of nitrogen oxides calculated on the basis of the method and emission determined experimentally show that forecasting accuracy is high and errors do not exceed 10%. 5 references.

  3. Fire Response of Concrete Filled Hollow Steel Sections

    DEFF Research Database (Denmark)

    Nyman, Simon; Virdi, Kuldeep

    2011-01-01

    Advanced and simplified methods of analysis and design for the fire resistance of structural elements and assemblages of structures have been developed in recent years. Some simplified methods for the fire design of concrete filled tubes have appeared in Eurocode 4 part 1.2. Experience to date in...... hollow sections....

  4. Adsorber fires

    International Nuclear Information System (INIS)

    Holmes, W.

    1987-01-01

    The following conclusions are offered with respect to activated charcoal filter systems in nuclear power plants: (1) The use of activated charcoal in nuclear facilities presents a potential for deep-seated fires. (2) The defense-in-depth approach to nuclear fire safety requires that if an ignition should occur, fires must be detected quickly and subsequently suppressed. (3) Deep-seated fires in charcoal beds are difficult to extinguish. (4) Automatic water sprays can be used to extinguish fires rapidly and reliably when properly introduced into the burning medium. The second part of the conclusions offered are more like challenges: (1) The problem associated with inadvertent actuations of fire protection systems is not a major one, and it can be reduced further by proper design review, installation, testing, and maintenance. Eliminating automatic fire extinguishing systems for the protection of charcoal adsorbers is not justified. (2) Removal of automatic fire protection systems due to fear of inadvertent fire protection system operation is a case of treating the effect rather than the cause. On the other hand, properly maintaining automatic fire protection systems will preserve the risk of fire loss at acceptable levels while at the same time reducing the risk of damage presented by inadvertent operation of fire protection systems

  5. Fabrication of Robust Super hydrophobic Bamboo Based on ZnO Nano sheet Networks with Improved Water-, UV-, and Fire-Resistant Properties

    International Nuclear Information System (INIS)

    Li, J.; Sun, Q.; Yao, Q.; Wang, J.; Han, Sh.; Jin, Ch.

    2014-01-01

    Bamboo with water-resistant, UV-resistant, and fire-resistant properties was desirable in modern society. In this paper, the original bamboo was firstly treated with ZnO sol and then hydrothermally the ZnO nano sheet networks grow onto the bamboo surface and subsequently modified with fluoro alkyl silane (FAS-17). The FAS-17 treated bamboo substrate exhibited not only robust super hydrophobicity with a high contact angle of 161° but also stable repellency towards simulated acid rain (ph = 3) with a contact angle of 152°. Except for its robust super hydrophobicity, such a bamboo also presents superior water-resistant, UV-resistant, and fire-resistant properties.

  6. Fabrication of Robust Superhydrophobic Bamboo Based on ZnO Nanosheet Networks with Improved Water-, UV-, and Fire-Resistant Properties

    Directory of Open Access Journals (Sweden)

    Jingpeng Li

    2015-01-01

    Full Text Available Bamboo with water-resistant, UV-resistant, and fire-resistant properties was desirable in modern society. In this paper, the original bamboo was firstly treated with ZnO sol and then hydrothermally the ZnO nanosheet networks grow onto the bamboo surface and subsequently modified with fluoroalkyl silane (FAS-17. The FAS-17 treated bamboo substrate exhibited not only robust superhydrophobicity with a high contact angle of 161° but also stable repellency towards simulated acid rain (pH = 3 with a contact angle of 152°. Except for its robust superhydrophobicity, such a bamboo also presents superior water-resistant, UV-resistant, and fire-resistant properties.

  7. New design on air-core resistive NMR imaging magnet

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yan; Mingwu, Fan; Yixin, Miao

    1984-08-01

    A new type of NMR imaging air-core resistive magnet is designed. Based on the BIM Magnetostatic calculation the resultant four equiradial coils structure with optimized shapes of cross section possesses a larger spherical working volume obviously, comparing with the common four-coils imaging magnet. The manufacturing tolerance is also calculated.

  8. Recent amendments of the KTA 2101.2 fire barrier resistance rating method for German NPP and comparison to the Eurocode t-equivalent method

    Energy Technology Data Exchange (ETDEWEB)

    Forell, Burkhard [Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) gGmbH, Koeln (Germany)

    2015-12-15

    The German nuclear standard KTA2101 on ''Fire Protection in Nuclear Power Plants'', Part 2: ''Fire Protection of Structural Plant Components'' includes a simplified method for the fire resistance rating of fire barrier elements based on the t-equivalent approach. The method covers the specific features of compartments in nuclear power plant buildings in terms of the boundary conditions which have to be expected in the event of fire. The method has proven to be relatively simple and straightforward to apply. The paper gives an overview of amendments with respect to the rating method made within the regular review of the KTA 2101.2. A comparison to the method of the non-nuclear Eurocode 1 is also provided. The Eurocode method is closely connected to the German standard DIN 18230 on structural fire protection in industrial buildings. Special emphasis of the comparison is given to the ventilation factor, which has a large impact on the required fire resistance.

  9. Development of aircraft lavatory compartments with improved fire resistance characteristics. Phase 4: Sandwich panel decorative ink development

    Science.gov (United States)

    Jayarajan, A.; Johnson, G. A.; Korver, G. L.; Anderson, R. A.

    1983-01-01

    Five chemically different resin systems with improved fire resistance properties were studied for a possible screenprinting ink application. Fire resistance is hereby defined as the cured ink possessing improvements in flammability, smoke emission, and thermal stability. The developed ink is for application to polyvinyl fluoride film. Only clear inks without pigments were considered. Five formulations were evaluated compared with KC4900 clear acrylic ink, which was used as a baseline. The tests used in the screening evaluation included viscosity, smoke and toxic gas emission, limiting oxygen index (LOI), and polyvinyl fluoride film (PVF) printability. A chlorofluorocarbon resin (FPC461) was selected for optimization studies. The parameters for optimization included screenprinting process performance, quality of coating, and flammability of screenprinted 0.051-mm (0.002-in.) white Tedlar. The quality of the screenprinted coating on Tedlar is dependent on viscosity, curing time, adhesion to polyvinyl fluoride film, drying time (both inscreen and as an applied film), and silk screen mesh material and porosity.

  10. To Enhance the Fire Resistance Performance of High-Speed Steel Roller Door with Water Film System

    Directory of Open Access Journals (Sweden)

    De-Hua Chung

    2015-01-01

    Full Text Available The structure of high-speed roller door with water film has improved in this study. The flameproof water film system is equipped with a water circulating device to reduce the water consumption of water film system. The water film is generated at the roller box of the high-speed roller door in this study. The heating test is done with the full-scale heating furnace. Both cases of the water film on unexposed surface and water film on exposed surface passed the fire resistance test based on ISO 834, proving that the high-speed roller door with water film system has 120A fire resistance period. The main findings indicate that the water film on exposed surface shows that as the amount of water film evaporated by high temperature inside the furnace must be greater than the evaporation capacity of water film on unexposed surface, the required water supply is 660 L more than the water film on unexposed surface.

  11. Fire resistant behaviour of cellulosic textile functionalized with wastage plant bio-molecules: A comparative scientific report.

    Science.gov (United States)

    Basak, Santanu; Wazed Ali, S

    2018-07-15

    Three different wastage plant based bio-molecules named banana peel powder (Musa acuminata) (BPP), coconut shell (Cocos nucifera) extract (CSE) and pomegranate rind (Punica granatum) extract (PRE) have been explored as fire resistant material on the cellulosic polymer (cotton fabric). To this end, extracts have been applied to the cotton fabric in different concentration at elevated temperature for specific time period. Treated cotton fabric showed 6 (BPP), 8.5 (CSE) and 12 (PRE) times lower vertical burning rate compared to the control cotton fabric. Thermo-gravimetry (TG) curves and the limiting oxygen index (LOI) value revealed that the PRE extract (LOI: 32) treated fabric encompassed more thermal stability compared to the BPP (LOI:26) and the CSE (LOI: 27) treated fabric as it showed higher oxygen index and more weight retention (40%) at higher temperature 450°C. Moreover, the carbonaceous samples remained after the burning of the extracts and the treated fabrics showed structural integration and more carbon content [65.6 (PRE extract) and 76.3% (PRE treated cotton)] compared to the fragile, net like char of the control cotton fabric, having less carbon content (49.8%). Gas Chromatography Mass spectroscopy (GC-MS) of the different extracts (CSE, PRE, BPP) used for the study showed the presence of high molecular weight aromatic phenolic compounds, tannin based compound and the nitrogen containing alkaloids, responsible for fire resistant effect of the different extract treated fabric. Besides fire retardancy, all the treated fabric showed attractive natural colour (measured by colour strength values) and there has been no adverse effect on the tensile strength property of the fabric after the treatment. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Development of fire-resistant, low smoke generating, thermally stable end items for aircraft and spacecraft

    Science.gov (United States)

    Gagliani, J.

    1978-01-01

    A new approach to the problem of flammability by the use of materials obtained from foamy polyimide resins is developed. The ability of these materials to provide fire protection is demonstrated. The development of processes for producing resilient cell foam for use in aircraft seating, thermal acoustical insulation, floor and wall panels, coated glass fabrics, and molded hardware.

  13. Resistance to invasion and resilience to fire in desert shrublands of North America

    Science.gov (United States)

    Matthew L. Brooks; Jeanne C. Chambers

    2011-01-01

    Settlement by Anglo-Americans in the desert shrublands of North America resulted in the introduction and subsequent invasion of multiple nonnative grass species. These invasions have altered presettlement fire regimes, resulted in conversion of native perennial shrublands to nonnative annual grasslands, and placed many native desert species at risk. Effective...

  14. Conceptual design of a commercial tokamak reactor using resistive magnets

    International Nuclear Information System (INIS)

    LeClaire, R.J. Jr.

    1988-01-01

    The future of the tokamak approach to controlled thermonuclear fusion depends in part on its potential as a commercial electricity-producing device. This potential is continually being evaluated in the fusion community using parametric, system, and conceptual studies of various approaches to improving tokamak reactor design. The potential of tokamaks using resistive magnets as commercial electricity-producing reactors is explored. Parametric studies have been performed to examine the major trade-offs of the system and to identify the most promising configurations for a tokamak using resistive magnets. In addition, a number of engineering issues have been examined including magnet design, blanket/first-wall design, and maintenance. The study indicates that attractive design space does exist and presents a conceptual design for the Resistive Magnet Commercial Tokamak Reactor (RCTR). No issue has been identified, including recirculating power, that would make the overall cost of electricity of RCTR significantly different from that of a comparably sized superconducting tokamak. However, RCTR may have reliability and maintenance advantages over commercial superconducting magnet devices

  15. Nonvolatile memory design magnetic, resistive, and phase change

    CERN Document Server

    Li, Hai

    2011-01-01

    The manufacture of flash memory, which is the dominant nonvolatile memory technology, is facing severe technical barriers. So much so, that some emerging technologies have been proposed as alternatives to flash memory in the nano-regime. Nonvolatile Memory Design: Magnetic, Resistive, and Phase Changing introduces three promising candidates: phase-change memory, magnetic random access memory, and resistive random access memory. The text illustrates the fundamental storage mechanism of these technologies and examines their differences from flash memory techniques. Based on the latest advances,

  16. A Shape Optimization Study for Tool Design in Resistance Welding

    DEFF Research Database (Denmark)

    Bogomolny, Michael; Bendsøe, Martin P.; Hattel, Jesper Henri

    2009-01-01

    The purpose of this study is to apply shape optimization tools for design of resistance welding electrodes. The numerical simulation of the welding process has been performed by a simplified FEM model implemented in COMSOL. The design process is formulated as an optimization problem where...... the objective is to prolong the life-time of the electrodes. Welding parameters like current, time and electrode shape parameters are selected to be the design variables while constraints are chosen to ensure a high quality of the welding. Surrogate models based on a Kriging approximation has been used in order...

  17. Structures to Resist the Effects of Accidental Explosions. Volume 6. Special Considerations in Explosive Facility Design

    Science.gov (United States)

    1985-04-01

    addition to their Inherent advantages with respect to fire protection, acoustical and thermal insulation, structural mass and resistance to flying...suspended from a monorail system. The panel is inside the shield and is not rigidly attached to the column members. Special consideration was given to...characteristic pulse emitted by an explosion to prevent actuation by other sources such as lightning, fires , etc., **ich cay occur with flash sensors. ■112

  18. Overview of seismic resistant design of Indian Nuclear Power Plants

    International Nuclear Information System (INIS)

    Sharma, G.K.; Hawaldar, R.V.K.P.; Vinod Kumar

    2007-01-01

    Safe operation of a Nuclear Power Plant (NPP) is of utmost importance. NPPs consist of various Structure, System and Equipment (SS and E) that are designed to resist the forces generated due to a natural phenomenon like earthquake. An earthquake causes severe oscillatory ground motion of short duration. Seismic resistant design of SS and E calls for evaluation of effect of severe ground shaking for assuring the structural integrity and operability during and after the occurrence of earthquake event. Overall exercise is a multi-disciplinary approach. First of standardized 220 MWe design reactor is Narora Atomic Power Station. Seismic design was carried out as per state of art then, for the first time. The twelve 220 MWe reactors and two 540 MWe reactors designed since 1975 have been seismically qualified for the earthquake loads expected in the region. Seismic design of 700 MWe reactor is under advanced stage of finalization. Seismic re-evaluation of six numbers of old plants has been completed as per latest state of art. Over the years, expertise have been developed at Nuclear Power Corporation of India Limited, Bhabha Atomic Research Centre, prominent educational institutes, research laboratories and engineering consultants in the country in the area of seismic design, analysis and shake table testing. (author)

  19. Design and Implementation of Software for Resistance Welding Process Simulations

    DEFF Research Database (Denmark)

    Zhang, Wenqi

    2003-01-01

    Based on long time engineering research and dedicated collaborations with industry, a new welding software, SORPAS, has been developed for simulation of resistance projection and spot welding processes applying the powerful finite element method (FEM). In order to make the software directly usabl...... equipment manufacturers...... by engineers and technicians in industry, all of the important parameters in resistance welding are considered and automatically implemented into the software. With the specially designed graphic user interface for Windows, engineers (even without prior knowledge of FEM) can quickly learn and easily operate...... and utilize the software. All industrial users, including welding engineers from DaimlerChrysler, Volkswangen, PSA Peugeot Citroen, VOLVO, Siemens, ABB and so on, have started using the software just after taking a one-day training course. With the user-friendly facilities for flexible geometric design...

  20. Design of a pressurized water loop heated by electric resistances

    International Nuclear Information System (INIS)

    Ribeiro, S.V.G.

    1981-01-01

    A pressurized water loop design is presented. Its operating pressure is 420 psi and we seek to simulate qualitatively some thermo-hydraulic phenomena of PWR reactors. The primary circuit simulator consists basically of two elements: 1)the test section housing 16 electric resistences dissipating a total power of 100 Kw; 2)the loop built of SCH40S 304L steel piping, consisting of the pump, a heat exchanger and the pressurizer. (Author) [pt

  1. Designing and Maintaining a Communication Consulting Relationship: A Fire Officer Case Study

    Science.gov (United States)

    Cragan, John F.

    2008-01-01

    This case study describes a 35-year communication consulting relationship with the Illinois Fire Chiefs' Association. This case explains the fire chiefs' educational problems, the five-step method for creating an educational curriculum for fire officers, and the five-step procedure for continuous evaluation of the curriculum. Finally, an…

  2. U.S. position paper on sodium fires, design and testing

    International Nuclear Information System (INIS)

    Hilliard, R.K.; Johnson, R.P.; Powers, D.A.

    1982-05-01

    Sodium combustion phenomena and U.S. computer codes developed for sodium fires are discussed. Ways of preventing and mitigating sodium fires are described. Effects of sodium fires and spills on LMFBR structural materials, thermal insulation materials, and equipment/instrumentation are considered

  3. Hazardous air pollutant emissions from gas-fired combustion sources: emissions and the effects of design and fuel type

    Energy Technology Data Exchange (ETDEWEB)

    England, G.C.; McGrath, T.P. [GE-Energy and Environmental Research Corp., Irvine, CA (United States); Gilmer, L. [Equilon Enterprises, Bellaire, TX (United States); Seebold, J.G. [Chevron Research and Technology Co., Richmond, CA (United States); Lev-On, M. [ARCO, Los Angeles, CA (United States); Hunt, T. [American Petroleum Institute, Washington, DC (United States)

    2001-07-01

    Air emissions from gas-fired combustion devices such as boilers, process heaters, gas turbines and stationary reciprocating engines contain hazardous air pollutants (HAPs) subjected to consideration under the federal clean air act (CAA). This work presents a recently completed major research project to develop an understanding of HAP emissions from gas-fired boilers and process heaters and new HAP emission factors based on field emission tests of gas-fired external combustion devices used in the petroleum industry. The effect of combustion system design and operating parameters on HAP emissions determined by both field and research tests are discussed. Data from field tests of gas-fired petroleum industry boilers and heaters generally show very low emission levels of organic HAPs. A comparison of the emission data for boilers and process heaters, including units with and without various forms of NO{sub x} emission controls, showed no significant difference in organic HAP emission characteristics due to process or burner design. This conclusion is also supported by the results of research tests with different burner designs. Based on field tests of units fired with natural gas and various petroleum industry process gases and research tests in which gas composition was intentionally varied, organic HAP emissions were not determined to be significantly affected by the gas composition. Research data indicate that elevated organic HAP emission levels are found only under extreme operating conditions (starved air or high excess air combustion) associated with poor combustion. (author)

  4. Hazardous air pollutant emissions from gas-fired combustion sources: emissions and the effects of design and fuel type

    International Nuclear Information System (INIS)

    England, G.C.; McGrath, T.P.; Gilmer, L.; Seebold, J.G.; Lev-On, M.; Hunt, T.

    2001-01-01

    Air emissions from gas-fired combustion devices such as boilers, process heaters, gas turbines and stationary reciprocating engines contain hazardous air pollutants (HAPs) subjected to consideration under the federal clean air act (CAA). This work presents a recently completed major research project to develop an understanding of HAP emissions from gas-fired boilers and process heaters and new HAP emission factors based on field emission tests of gas-fired external combustion devices used in the petroleum industry. The effect of combustion system design and operating parameters on HAP emissions determined by both field and research tests are discussed. Data from field tests of gas-fired petroleum industry boilers and heaters generally show very low emission levels of organic HAPs. A comparison of the emission data for boilers and process heaters, including units with and without various forms of NO x emission controls, showed no significant difference in organic HAP emission characteristics due to process or burner design. This conclusion is also supported by the results of research tests with different burner designs. Based on field tests of units fired with natural gas and various petroleum industry process gases and research tests in which gas composition was intentionally varied, organic HAP emissions were not determined to be significantly affected by the gas composition. Research data indicate that elevated organic HAP emission levels are found only under extreme operating conditions (starved air or high excess air combustion) associated with poor combustion. (author)

  5. Evaluation of the Ventilation and Air Cleaning System Design Concepts for Safety Requirements during Fire Conditions in Nuclear Applications

    International Nuclear Information System (INIS)

    Rashad, S.; El-Fawal, M.; Kandil, M.

    2013-01-01

    The ventilation and air cleaning system in the nuclear or radiological installations is one of the essential nuclear safety concerns. It is responsible for confining the radioactive materials involved behind suitable barriers during normal and abnormal conditions. It must be designed to prevent the release of harmful products (radioactive gases, or airborne radioactive materials) from the system or facility, impacting the public or workers, and doing environmental damage. There are two important safety functions common to all ventilation and air cleaning system in nuclear facilities. They are: a) the requirements to maintain the pressure of the ventilated volume below that of surrounding, relatively non-active areas, in order to inhibit the spread of contamination during normal and abnormal conditions, and b) the need to treat the ventilated gas so as to minimize the release of any radioactive or toxic materials. Keeping the two important safety functions is achieved by applying the fire protection for the ventilation system to achieve safety and adequate protection in nuclear applications facilities during fire and accidental criticality conditions.The main purpose of this research is to assist ventilation engineers and experts in nuclear installations for safe operation and maintaining ventilation and air cleaning system during fire accident in nuclear facilities. The research focuses on fire prevention and protection of the ventilation systems in nuclear facilities. High-Efficiency particulate air (HEPA) filters are extremely susceptible to damage when exposed to the effects of fire, smoke, and water; it is the intent of this research to provide the designer with the experience gained over the years from hard lessons learned in protecting HEPA filters from fire. It describes briefly and evaluates the design safety features, constituents and working conditions of ventilation and air cleaning system in nuclear and radioactive industry.This paper provides and

  6. Fatigue characteristics of high strength fire resistance steel for frame structure and time-frequency analysis its acoustic emission signal

    International Nuclear Information System (INIS)

    Kim, Hyun Soo; Nam, Ki Woo; Kang, Chang Young

    2000-01-01

    Demand for now nondestructive evaluation are growing to detect fatigue crack growth behavior to predict long term performance of materials and structure in aggressive environments, especially when they are in non-visible area. Acoustic emission technique is well suited to these problems and has drawn a keen interests because of its dynamic detection ability, extreme sensitivity and location of growing defects. In this study, we analysed acoustic emission signals obtained in fatigue and tensile test of high strength fire resistance steel for frame structure with time-frequency analysis methods. The main frequency range is different in the noise and the fatigue crack propagation. It could be classified that it were also generated by composite fracture mechanics of cleavage, dimple, inclusion separation etc

  7. A novel method to design water spray cooling system to protect floating roof atmospheric storage tanks against fires

    Directory of Open Access Journals (Sweden)

    Iraj Alimohammadi

    2015-01-01

    Full Text Available Hydrocarbon bulk storage tank fires are not very common, but their protection is essential due to severe consequences of such fires. Water spray cooling system is one of the most effective ways to reduce damages to a tank from a fire. Many codes and standards set requirements and recommendations to maximize the efficiency of water spray cooling systems, but these are widely different and still various interpretations and methods are employed to design such systems. This article provides a brief introduction to some possible design methods of cooling systems for protection of storage tanks against external non-contacting fires and introduces a new method namely “Linear Density Method” and compares the results from this method to the “Average Method” which is currently in common practice. The average Method determines the flow rate for each spray nozzle by dividing the total water demand by the number of spray nozzles while the Linear Density Method determines the nozzle flow rate based on the actual flow over the surface to be protected. The configuration of the system includes a one million barrel crude oil floating roof tank to be protected and which is placed one half tank diameter from a similar adjacent tank with a full surface fire. Thermal radiation and hydraulics are modeled using DNV PHAST Version 6.53 and Sunrise PIPENET Version 1.5.0.2722 software respectively. Spray nozzles used in design are manufactured by Angus Fire and PNR Nozzles companies. Schedule 40 carbon steel pipe is used for piping. The results show that the cooling system using the Linear Density Method consumes 3.55% more water than the design using the average method assuming a uniform application rate of 4.1 liters per minute. Despite higher water consumption the design based on Linear Density Method alleviates the problems associated with the Average Method and provides better protection.

  8. Design of an experiment to measure fire exposure of packages aboard container cargo ships

    International Nuclear Information System (INIS)

    Koski, J.A.

    1998-01-01

    The test described in this paper is intended to measure the typical accident environment for a radioactive materials package in a fire abroad a container cargo ship. A stack of nice used standard cargo containers will be variously loaded with empty packages, simulated packages and combustible cargo and placed over a large hydrocarbon pool fire of one hour duration. Fire environments, both inside and outside the containers, typical of on-deck stowage will be measured as well as the potential for container-to-container fire spread. With the use of the inverse heat conduction calculations, the local heat transfer to the simulated packages can be estimated from thermocouple data. Data recorded will also provide information on fire durations in each container, fire intensity and container-to-container fire spread characteristics. (authors)

  9. Development of fire PRA methodologies for the analysis of typical Italian NPP designs

    International Nuclear Information System (INIS)

    Silvestri, E.; Dore, B.; Ferro, G.; Apostolakis, G.

    1987-01-01

    To compute fire induced Core Melt probability, the results of hazard and propagation analyses were combined with the Core Melt frequency computed for the initiating event and the support state as determined by the fire considered. From the PRA for internal event, the average value of this frequency was found 2.5x10 -3 event/year. Using the average fire frequency the resulting fire induced Core Melt frequency is 1.4x10 -8 event/year. Although high separation of safety systems is required in Italian PWR plants, the frequency of fire induced Core Melt can reach values not negligible with respect to Italian safety standards. For this reason, fire PRA studies for the entire plant are considered necessary and should be performed with appropriate modifications of the methods used for the American plants in order to be able to estimate lower fire induced Core Melt frequencies. (orig./HP)

  10. Assessment of the Fire Risk Levels in an Office Building and a Nightclub with Prescriptive Designs

    DEFF Research Database (Denmark)

    Yilmaz, D.; Steffensen, F.B.; Jomaas, Grunde

    2014-01-01

    A comparison of the risk level of an office building and a nightclub with code compliant prescriptive designs was conducted in order to evaluate whether an uniform safety level of the two occupancy types can be established. A risk assessment method using Monte Carlo simulations and 1- and 2-zone......-movement time and the movement time were adjusted for the required safe egress time (RSET) of the nightclub. The number of simulations required in order to obtain reliable results was considered sufficient at 20,000. The comparison of the risk profiles of the nightclub and the office building showed significant...... difference in risk levels, with that of the nightclub being substantially higher. The higher risk level in the nightclub is caused by a relatively fast mean value of the fire growth rate and the high number of occupants. Hence, the requirements in the prescriptive code do not ensure a similar safety level...

  11. Thermodynamic analysis and conceptual design for partial coal gasification air preheating coal-fired combined cycle

    Science.gov (United States)

    Xu, Yue; Wu, Yining; Deng, Shimin; Wei, Shirang

    2004-02-01

    The partial coal gasification air pre-heating coal-fired combined cycle (PGACC) is a cleaning coal power system, which integrates the coal gasification technology, circulating fluidized bed technology, and combined cycle technology. It has high efficiency and simple construction, and is a new selection of the cleaning coal power systems. A thermodynamic analysis of the PGACC is carried out. The effects of coal gasifying rate, pre-heating air temperature, and coal gas temperature on the performances of the power system are studied. In order to repower the power plant rated 100 MW by using the PGACC, a conceptual design is suggested. The computational results show that the PGACC is feasible for modernizing the old steam power plants and building the new cleaning power plants.

  12. THE CONCEPTUAL DESIGN ASSESSMENT FOR THE CO-FIRING OF BIO-REFINERY SUPPLIED LIGNIN PROJECT

    International Nuclear Information System (INIS)

    Ted Berglund; Jeffrey T. Ranney; Carol L. Babb; Jacqueline G. Broder

    2001-01-01

    The major aspects of this project are proceeding toward completion. Prior to this quarter, design criteria, tentative site selection, facility layout, and preliminary facility cost estimates were completed and issued. Processing of bio-solids was completed, providing material for the pilot operations. Pilot facility design, equipment selection, and modification were completed during the fourth quarter of 2000. Initial pilot facility shakedown was completed during the fourth quarter. After some unavoidable delays, a suitable representative supply of MSW feed material was procured. During this first quarter of 2001, shredding of the feed material and final feed conditioning were completed. Pilot facility hydrolysis production was completed to produce lignin for co-fire testing. During this quarter, TVA completed the washing and dewatering of the lignin material produced from the MSW hydrolysis. Seven drums of lignin material were washed to recover the acid and sugar from the lignin and provide an improved fuel for steam generation. Samples of both the lignin and bio-solids fuel materials for co-fire testing were sent to the co-fire facility (EERC) for evaluation. After sample evaluation, EERC approved sending the material and all of the necessary fuel for testing was shipped to EERC. EERC has requested and will receive coal typical of the fuel to the TVA-Colbert boilers. This material will be used at EERC as baseline material and for mixing with the bio-fuel for combustion testing. EERC combustion testing of the bio based fuels is scheduled to begin in August of 2001. The TVA-Colbert facility has neared completion of the task to evaluate the co-location of the Masada facility on the operation of the power generation facility. The TVA-Colbert fossil plant is fully capable of providing a reliable steam supply. The preferred steam supply connection points and steam pipeline routing have been identified. The environmental review of the pipeline routing has been completed

  13. Predictions of fire behavior and resistance to control: for use with photo series for the ponderosa pine type, ponderosa pine and associated species type, and lodgepole pine type.

    Science.gov (United States)

    Franklin R. Ward; David V. Sandberg

    1981-01-01

    This publication presents tables on the behavior of fire and the resistance of fuels to control. The information is to be used with the publication, "Photo Series for Quantifying Forest Residues in the Ponderosa Pine Type, Ponderosa Pine and Associated Species Type, Lodgepole Pine Type" (Maxwell, Wayne G.; Ward, Franklin R. 1976. Gen. Tech. Rep. PNW-GTR-052....

  14. Connective Heating Improvement for Emergency Fire Shelters (CHIEFS): Composition and Performance of Fire Shelter Concepts at Close-Out

    Science.gov (United States)

    Fody, Joshua M.; Daryabeigi, Kamran; Bruce, Walter E., III; Wells, John M.; Wusk, Mary E.; Calomino, Anthony M.; Miller, Steve D.

    2018-01-01

    Summary of highlights of the Convective Heating Improvement for Emergency Fire Shelters (CHIEFS) taskunder NASA. CHIEFS was tasked with providing the US Forest Service with an emergency fire shelter forimproved resistance to flame contact. Emphasis is on the final shelter designs at task close-out (end of FY17).

  15. On ethics and the earthquake resistant interior design of buildings.

    Science.gov (United States)

    Hurol, Yonca

    2014-03-01

    The most common tectonic quality of modern structures, such as frame systems, is their flexibility; they are open for change. Although this characteristic is a big advantage in comparison to the inflexible masonry structures of the past, it might also create some serious problems, such as e.g. the lack of safety in the event of an earthquake, if the flexibility is not used consciously by architects and interior designers. This article attempts to define and establish some rules for the interior design of buildings with reinforced concrete frame systems. The rules for making subtractions from these structures and extending them by making additions to them are contained within this article. The main objective of this article is to derive some ethical values from these rules. Thus, the conclusion of the article focuses on the derivation of some ethical values for achieving earthquake resistant interior design of buildings with reinforced concrete frame systems.

  16. Soft shell hard core concept for aircraft impact resistant design

    International Nuclear Information System (INIS)

    Chen, C.; Rieck, P.J.

    1978-01-01

    For nuclear power plants sited in the vicinity of airports, the hypothetical events of aircraft impact have to be designed for. The conventional design concept is to strengthen the exterior structure to resist the impact induced force. The stiffened structures have two (2) disadvantages; one is the high construction cost, and the other is the high reaction force induced as well as the vibrational effects on the interior equipment and piping systems. This new soft shell hard core concept can relieve the above shortcomings. In this concept, the essential equipment required for safety are installed inside the hard core area for protection and the non-essential equipment are maintained between the hard core and soft shell area. During a hypothetical impact event, the soft shell will collapse locally and absorb large amounts of kinetic energy; hence, it reduces the reaction force and the vibrational effects. The design and analysis of the soft shell concept are discussed. (Author)

  17. Development of a new composite system: fire resistant and highly structural

    Directory of Open Access Journals (Sweden)

    González, J.

    2010-06-01

    Full Text Available Infrastructure and rail sectors share two singularities in terms of materials: highly structural performance and strict fire requirements. Moreover, there is a common growing interest in both sectors: the use of organic matrix composite materials due to their high performance, lightweight and in-service behavior. Traditionally, fire fillers have been added to the matrix, decreasing its mechanical performance in a critical way. A study about composite materials formed by three different matrices and four different carbon fibers will be presented in this paper. A number of laminates have been manufactured by using these composite materials in order to analyze both the resin processing and the compatibility of the different matrices and fibers. This study is a need due to the fact that these matrices are fire-related and therefore further problems may arise in comparison with standard matrices.

    Los sectores de la construcción y del ferrocarril tienen dos aspectos en común en el ámbito de los materiales: la utilización de materiales altamente estructurales y la aplicación de estrictos requerimientos de fuego. Asimismo, en ambos sectores existe un interés creciente en el uso de materiales compuestos de matriz orgánica por sus excelentes prestaciones, ligereza y comportamiento en servicio. Tradicionalmente, se han aplicado cargas anti-fuego a la matriz orgánica, disminuyendo sus propiedades mecánicas de forma importante. En este artículo se presentará un estudio de materiales compuestos formados por tres matrices orgánicas diferentes y cuatro tipos de fibras de carbono. Con estos constituyentes se han fabricado diferentes laminados para analizar, por un lado, la procesabilidad de estas resinas, y, por otro, la compatibilidad de estas resinas con las fibras de refuerzo utilizadas. Este estudio es necesario debido a que al tratarse de resinas formuladas con características frente a fuego y humos, su fabricabilidad puede

  18. Proliferation resistance design of a plutonium cycle (Proliferation Resistance Engineering Program: PREP)

    Energy Technology Data Exchange (ETDEWEB)

    Sorenson, R.J.; Roberts, F.P.; Clark, R.G.

    1979-01-19

    This document describes the proliferation resistance engineering concepts developed to counter the threat of proliferation of nuclear weapons in an International Fuel Service Center (IFSC). The basic elements of an International Fuel Service Center are described. Possible methods for resisting proliferation such as processing alternatives, close-coupling of facilities, process equipment layout, maintenance philosophy, process control, and process monitoring are discussed. Political and institutional issues in providing proliferation resistance for an International Fuel Service Center are analyzed. The conclusions drawn are (1) use-denial can provide time for international response in the event of a host nation takeover. Passive use-denial is more acceptable than active use-denial, and acceptability of active-denial concepts is highly dependent on sovereignty, energy dependence and economic considerations; (2) multinational presence can enhance proliferation resistance; and (3) use-denial must be nonprejudicial with balanced interests for governments and/or private corporations being served. Comparisons between an IFSC as a national facility, an IFSC with minimum multinational effect, and an IFSC with maximum multinational effect show incremental design costs to be less than 2% of total cost of the baseline non-PRE concept facility. The total equipment acquisition cost increment is estimated to be less than 2% of total baseline facility costs. Personnel costs are estimated to increase by less than 10% due to maximum international presence. 46 figures, 9 tables.

  19. Proliferation resistance design of a plutonium cycle (Proliferation Resistance Engineering Program: PREP)

    International Nuclear Information System (INIS)

    Sorenson, R.J.; Roberts, F.P.; Clark, R.G.

    1979-01-01

    This document describes the proliferation resistance engineering concepts developed to counter the threat of proliferation of nuclear weapons in an International Fuel Service Center (IFSC). The basic elements of an International Fuel Service Center are described. Possible methods for resisting proliferation such as processing alternatives, close-coupling of facilities, process equipment layout, maintenance philosophy, process control, and process monitoring are discussed. Political and institutional issues in providing proliferation resistance for an International Fuel Service Center are analyzed. The conclusions drawn are (1) use-denial can provide time for international response in the event of a host nation takeover. Passive use-denial is more acceptable than active use-denial, and acceptability of active-denial concepts is highly dependent on sovereignty, energy dependence and economic considerations; (2) multinational presence can enhance proliferation resistance; and (3) use-denial must be nonprejudicial with balanced interests for governments and/or private corporations being served. Comparisons between an IFSC as a national facility, an IFSC with minimum multinational effect, and an IFSC with maximum multinational effect show incremental design costs to be less than 2% of total cost of the baseline non-PRE concept facility. The total equipment acquisition cost increment is estimated to be less than 2% of total baseline facility costs. Personnel costs are estimated to increase by less than 10% due to maximum international presence. 46 figures, 9 tables

  20. Analysis of design strategies for mitigating the consequences of lithium fire within containment of controlled thermonuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Dube, D A; Kazimi, M S

    1978-07-01

    A lithium combustion model (LITFIRE) was developed to describe the physical and chemical processes which occur during a hypothetical lithium spill and fire. The model was used to study the effectiveness of various design strategies for mitigating the consequences of lithium fire, using the UWMAK-III features as a reference design. Calculations show that without any special fire protection measures, the containment may reach pressures of up to 32 psig when one coolant loop is spilled inside the reactor building. Temperatures as high as 2000/sup 0/F would also be experienced by some of the containment structures. These consequences were found to diminish greatly by the incorporation of a number of design strategies including initially subatmospheric containment pressures, enhanced structural surface heat removal capability, initially low oxygen concentrations, and active post-accident cooling of the containment gas. The EBTR modular design was found to limit the consequences of a lithium spill, and hence offers a potential safety advantage. Calculations of the maximum flame temperature resulting from lithium fire indicate that none of the radioactive first wall materials under consideration would vaporize, and only a few could possibly melt.

  1. Analysis of design strategies for mitigating the consequences of lithium fire within containment of controlled thermonuclear reactors

    International Nuclear Information System (INIS)

    Dube, D.A.; Kazimi, M.S.

    1978-07-01

    A lithium combustion model (LITFIRE) was developed to describe the physical and chemical processes which occur during a hypothetical lithium spill and fire. The model was used to study the effectiveness of various design strategies for mitigating the consequences of lithium fire, using the UWMAK-III features as a reference design. Calculations show that without any special fire protection measures, the containment may reach pressures of up to 32 psig when one coolant loop is spilled inside the reactor building. Temperatures as high as 2000 0 F would also be experienced by some of the containment structures. These consequences were found to diminish greatly by the incorporation of a number of design strategies including initially subatmospheric containment pressures, enhanced structural surface heat removal capability, initially low oxygen concentrations, and active post-accident cooling of the containment gas. The EBTR modular design was found to limit the consequences of a lithium spill, and hence offers a potential safety advantage. Calculations of the maximum flame temperature resulting from lithium fire indicate that none of the radioactive first wall materials under consideration would vaporize, and only a few could possibly melt

  2. HIV protease drug resistance and its impact on inhibitor design.

    Science.gov (United States)

    Ala, P J; Rodgers, J D; Chang, C H

    1999-07-01

    The primary cause of resistance to the currently available HIV protease inhibitors is the accumulation of multiple mutations in the viral protease. So far more than 20 substitutions have been observed in the active site, dimer interface, surface loops and flaps of the homodimer. While many mutations reduce the protease's affinity for inhibitors, others appear to enhance its catalytic efficiency. This high degree of genetic flexibility has made the protease an elusive drug target. The design of the next generation of HIV protease inhibitors will be discussed in light of the current structural information.

  3. Earthquake resistant design of nuclear facilities with limited radioactive inventory

    International Nuclear Information System (INIS)

    1985-10-01

    This document comprises the essential elements of an earthquake resistant design code for nuclear facilities with limited radioactive inventory. The purpose of the document is the enhancement of seismic safety for such facilities without the necessity to resort to complicated and sophisticated methodologies which are often associated with and borrowed from nuclear power plant analysis and design. The first two sections are concerned with the type of facility for which the document is applicable and the radiological consideration for accident conditions. The principles of facility classification and item categorization as a function of the potential radiological consequences of failure are given in section 3. The design basis ground motion is evaluated in sections 4-6 using a simplified but conservative approach which also includes considerations for the underlying soil characteristics. Sections 7 and 8 specify the principles of seismic design of building structures and equipment using two methods, called the equivalent static and simplified dynamic approach. Considerations for the detailing of equipment and piping and those other than for lateral load calculations, such as sloshing effects, are given in the subsequent sections. Several appendices are given for illustration of the principles presented in the text. Finally, a design tree diagram is included to facilitate the user's task of making the appropriate selections. (author)

  4. Design of power balance SRAM for DPA-resistance

    Science.gov (United States)

    Keji, Zhou; Pengjun, Wang; Liang, Wen

    2016-04-01

    A power balance static random-access memory (SRAM) for resistance to differential power analysis (DPA) is proposed. In the proposed design, the switch power consumption and short-circuit power consumption are balanced by discharging and pre-charging the key nodes of the output circuit and adding an additional short-circuit current path. Thus, the power consumption is constant in every read cycle. As a result, the DPA-resistant ability of the SRAM is improved. In 65 nm CMOS technology, the power balance SRAM is fully custom designed with a layout area of 5863.6 μm2. The post-simulation results show that the normalized energy deviation (NED) and normalized standard deviation (NSD) are 0.099% and 0.04%, respectively. Compared to existing power balance circuits, the power balance ability of the proposed SRAM has improved 53%. Project supported by the Zhejiang Provincial Natural Science Foundation of China (No. LQ14F040001), the National Natural Science Foundation of China (Nos. 61274132, 61234002), and the K. C. Wong Magna Fund in Ningbo University, China.

  5. Design and Development of Functionally Effective Human-Machine Interfaces for Firing Room Displays

    Science.gov (United States)

    Cho, Henry

    2013-01-01

    This project involves creating software for support equipment used on the Space Launch System (SLS). The goal is to create applications and displays that will be used to remotely operate equipment from the firing room and will continue to support the SLS launch vehicle to the extent of its program. These displays include design practices that help to convey information effectively, such as minimizing distractions at normal operating state and displaying intentional distractions during a warning or alarm state. The general practice for creating an operator display is to reduce the detail of unimportant aspects of the display and promote focus on data and dynamic information. These practices include using minimalist design, using muted tones for background colors, using a standard font at a readable text size, displaying alarms visible for immediate attention, grouping data logically, and displaying data appropriately varying on the type of data. Users of these displays are more likely to stay focused on operating for longer periods by using design practices that reduce eye strain and fatigue. Effective operator displays will improve safety by reducing human errors during operation, which will help prevent catastrophic accidents. This report entails the details of my work on developing remote displays for the Hypergolic fuel servicing system. Before developing a prototype display, the design and requirements of the system are outlined and compiled into a document. Then each subsystem has schematic representations drawn that meet the specifications detailed in the document. The schematics are then used as the outline to create display representations of each subsystem. Each display is first tested individually. Then the displays are integrated with a prototype of the master system, and they are tested in a simulated environment then retested in the real environment. Extensive testing is important to ensure the displays function reliably as intended.

  6. Microfine coal firing results from a retrofit gas/oil-designed industrial boiler

    Energy Technology Data Exchange (ETDEWEB)

    Patel, R.; Borio, R.W.; Liljedahl, G. [Combustion Engineering, Inc., Windsor, CT (United States)] [and others

    1995-11-01

    Under US Department of Energy, Pittsburgh Energy Technology Center (PETC) support, the development of a High Efficiency Advanced Coal Combustor (HEACC) has been in progress since 1987 at the ABB Power Plant Laboratories. The initial work on this concept produced an advanced coal firing system that was capable of firing both water-based and dry pulverized coal in an industrial boiler environment.

  7. Rationalization design on large equipment dismantling facility. The cell fire-extinguishing examination (3)

    International Nuclear Information System (INIS)

    Donomae, Yasushi; Matsumoto, Yoshihiro; Takita, Koji; Kikuchi, Yutaka; Katoh, Noriyoshi; Miyazaki, Hitoshi; Tanimoto, Ken-ichi

    2002-07-01

    In order to rationalize for Large Equipment Dismantling Facility (LEDF), the plan of removing vaporizer belong to Cell-fire-extinguishing-system was investigated. When a vaporizer is cut down, it is necessary to grasp a fire-extinguishing performance. The fire-extinguishing performance check examination by liquefaction carbon dioxide in the cell fire-extinguishing examination (I) was carried out in 1999 fiscal year. As the result, the good performance was obtained to polyethylene. But there was the deep-seated fire about a piece of wood. Then, the check items were carbon dioxide (CO2) concentration and CO2 concentration holding time for the deep-seated fire in the cell fire-extinguishing examination (III). The results were as follows; (1) By use of the combustion model in which a piece of wood and cotton were put is lit, temperature inside model, mass reduction, and combustion situation were examined. The model burned remarkably in 30∼60 min. The peak temperature rise to 680 degC (MAX), and attained smoldering after (ignition) 70 min. Moreover, in order to determine the generating conditions of a deep-seated fire, the situation of CO2 extinguishing after ignition by the time lag of 50∼90 min were examined. The model around ignition 50 minutes was the most difficult to extinguish, and it turned out that they are the conditions which were most suitable for the deep-seated fire examination model of an exam. (2) In order to decide on CO2 concentration and concentration holding time required for fire extinguishing of the deep-seated fire in LEDF, the fire-extinguishing performance was investigated by 40 ∼ 65% of CO2 concentration. Consequently, CO2 concentration required for deep-seated fire extinguishing was understood that 60% or more was required when safety was taken into consideration at 50% or more. Moreover, when it was 50% or more of CO2 concentration and the holding time of CO2 concentration was 180 minutes or more and 60% or more of CO2 concentration, it

  8. POWER SUPPLY MANAGEMENT SYSTEM DESIGN ON NODE EARLY WARNING SYSTEM FOR PEATLANDS FIRE MITIGATION

    Directory of Open Access Journals (Sweden)

    Taufiq Muammar

    2018-02-01

    Full Text Available Early warning system is one of the technology to detect land fires by utilizing a network of wireless sensors. Constant data transmission by the sensor nodes consumes a large amount of energy on the nodes’ sides that could affect the battery’s longevity. This research is done to discover the amount of power consumption and battery longevity during fire emergencies, and during non-emergency situation on peatlands. Power saving on the fire detecting system uses an LM35 temperature sensor, ATmega8 micro-controller and HC-12 transmission module. The overall result of powered by a 9 volt battery during fire emergencies, and during non-emergency, the power consumption reaches up to 1 Wh, with various longevity levels of the battery. The implementation of sleep/wake up mode scheduling during fire emergencies and non-emergencies could save battery for 2 hours compared to those without the power saving mode implementation. Power saving during fire emergency could be minimalized by activating the sleep mode activation power-down on the micro controller and it can also set the data transmission schedule to minimalize data usage during fire emergency, so that the usage of sleep/wake up mode interval scheduling during transmission could minimalize energy consumption and elongate the power supply active period.

  9. Evaluation of retrofitting gas-fired cooling and heating systems into BCHP using design optimization

    International Nuclear Information System (INIS)

    Cao Jiacong

    2009-01-01

    The influence of energy prices on the feasibility of a retrofit is investigated. The retrofit describes the conversion of a system from HVAC to BCHP for energy-saving. This includes two optimal retrofit design models, of which the exergetic efficiency and annual costs (AC) are the separate objective functions. The retrofit scheme is planned to insert gas engines as prime movers into the original system, which have adopted gas-fired absorption chillers. The solutions of the optimizations show that such a retrofit can result in a remarkable rise in exergetic efficiency but is not viable with current energy prices. The contradictory solutions reveal a gap between the current energy prices system of the country and the present energy situation. Further investigation gives the critical lines of which each divides the coordinate plane of natural gas-electric prices into two parts of benefit and deficit. If the electric price rises to a certain extent, the retrofit will be advantageous both in benefit and energy-saving. So it is really an urgent task to reform the energy prices system in China. Conclusions may be helpful for other similar retrofit projects, and for legislators and the government which are responsible for improving the energy market in China.

  10. Severe burn injuries caused by bioethanol-design fireplaces-an overview on recreational fire threats.

    Science.gov (United States)

    Kraemer, Robert; Knobloch, Karsten; Lorenzen, Johan; Breuing, Karl H; Koennecker, Soeren; Rennekampff, Hans-Oliver; Vogt, Peter M

    2011-01-01

    Commercially available bioethanol-fueled fireplaces have become increasingly popular additions for interior home decoration in Europe and more recently in the United States. These fireplaces are advertised as smokeless, ecologically friendly, and do not require professional installation, formal gas lines, or venting. Although manufacturers and businesses promote their safety, recent presentations of injuries have alerted the authors to the relevant danger bioethanol fireplaces can pose for the incautious user. Are bioethanol fireplaces going to become the future threat in domestic burn accidents beside common barbeque burns? A Medline literature search on barbeque and domestic fireplace accidents was performed to compare and stratify the injury patterns reported and to identify a risk profile for contemporary bioethanol-fueled fireplaces. To exemplify, two representative clinical cases of severe burn accidents caused by bioethanol-fueled fireplaces, both treated in the burn unit of the authors, are being presented. Design fireplaces are being recognized as an increasing source of fuel and fire-related danger in the home. This risk may be underestimated by the uninformed customer, resulting in severe burn injuries. Because bioethanol-fueled fireplaces have become more commonplace, they may overtake barbecue-related injury as the most common domestic burn injury.

  11. Final report on the radiological surveys of designated DX firing sites at Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    1996-01-01

    CHEMRAD was contracted by Los Alamos National Laboratory to perform USRADS reg-sign (UltraSonic Ranging And Data System) radiation scanning surveys at designated DX Sites at the Los Alamos National Laboratory. The primary purpose of these scanning surveys was to identify the presence of Depleted Uranium (D-38) resulting from activities at the DX Firing Sites. This effort was conducted to update the most recent surveys of these areas. This current effort was initiated with site orientation on August 12, 1996. Surveys were completed in the field on September 4, 1996. This Executive Summary briefly presents the major findings of this work. The detail survey results are presented in the balance of this report and are organized by Technical Area and Site number in section 2. This organization is not in chronological order. USRADS and the related survey methods are described in section 3. Quality Control issues are addressed in section 4. Surveys were conducted with an array of radiation detectors either mounted on a backpack frame for man-carried use (Manual mode) or on a tricycle cart (RadCart mode). The array included radiation detectors for gamma and beta surface near surface contamination as well as dose rate at 1 meter above grade. The radiation detectors were interfaced directly to an USRADS 2100 Data Pack

  12. SUS 321 HTB boiler tubing with fire grained internal surface resistant to steam-induced oxidation

    International Nuclear Information System (INIS)

    Kanero, Takahiro; Minami, Yuusuke; Kodera, Toshihide

    1981-01-01

    Considerable amount of scale is produced by high temperature steam on the austenitic stainless steel tubes used for the superheaters and reheaters of large boilers for power generation. The scale of outer layer separates off due to the thermal stress at the time of starting-up and stopping, and causes the blocking of pipes and the erosion of turbine blades. Following the increase of nuclear power generation, large boilers are used for medium load, accordingly it is expected that the troubles like these increase. In this paper, the manufacturing method and the properties of SUS 321 HTB with fine grain internal surface are reported, which was developed to reduce the rate of growth of scale and to prevent the separation of scale. In order to prevent the separation of scale from austenitic stainless steel tubes, the reduction of scale thickness, surface treatment such as chrome plating, the use of alloys with excellent oxidation resistance, the formation of chrome-rich film rapidly, the heat treatment of cold-worked tubes and so on were carried out. The nitrification of SUS 321 H steel brought about two-phase structure of the fine grain internal surface with excellent oxidation resistance and the rest of coarse grains with high creep strength. (Kako, I.)

  13. Seismic hazard maps for earthquake-resistant construction designs

    International Nuclear Information System (INIS)

    Ohkawa, Izuru

    2004-01-01

    Based on the idea that seismic phenomena in Japan varying in different localities are to be reflected in designing specific nuclear facilities in specific site, the present research program started to make seismic hazard maps representing geographical distribution of seismic load factors. First, recent research data on historical earthquakes and materials on active faults in Japan have been documented. Differences in character due to different localities are expressed by dynamic load in consideration of specific building properties. Next, hazard evaluation corresponding to seismic-resistance factor is given as response index (spectrum) of an adequately selected building, for example a nuclear power station, with the help of investigation results of statistical analysis. (S. Ohno)

  14. Design of a charge sensitive preamplifier on high resistivity silicon

    International Nuclear Information System (INIS)

    Radeka, V.; Rehak, P.; Rescia, S.; Gatti, E.; Longoni, A.; Sampietro, M.; Holl, P.; Strueder, L.; Kemmer, J.

    1987-01-01

    A low noise, fast charge sensitive preamplifier was designed on high resistivity, detector grade silicon. It is built at the surface of a fully depleted region of n-type silicon. This allows the preamplifier to be placed very close to a detector anode. The preamplifier uses the classical input cascode configuration with a capacitor and a high value resistor in the feedback loop. The output stage of the preamplifier can drive a load up to 20pF. The power dissipation of the preamplifier is 13mW. The amplifying elements are ''Single Sided Gate JFETs'' developed especially for this application. Preamplifiers connected to a low capacitance anode of a drift type detector should achieve a rise time of 20ns and have an equivalent noise charge (ENC), after a suitable shaping, of less than 50 electrons. This performance translates to a position resolution better than 3μm for silicon drift detectors. 6 refs., 9 figs

  15. Control of fire blight (Erwinia amylovora on apple trees with trunk-injected plant resistance inducers and antibiotics and assessment of induction of pathogenesis-related protein genes

    Directory of Open Access Journals (Sweden)

    Srđan G. Aćimović

    2015-02-01

    Full Text Available Management of fire blight is complicated by limitations on use of antibiotics in agriculture, antibiotic resistance development, and limited efficacy of alternative control agents. Even though successful in control, preventive antibiotic sprays also affect non-target bacteria, aiding the selection for resistance which could ultimately be transferred to the pathogen Erwinia amylovora. Trunk injection is a target-precise pesticide delivery method that utilizes tree xylem to distribute injected compounds. Trunk injection could decrease antibiotic usage in the open environment and increase the effectiveness of compounds in fire blight control. In field experiments, after 1-2 apple tree injections of either streptomycin, potassium phosphites (PH or acibenzolar-S-methyl (ASM, significant reduction of blossom and shoot blight symptoms was observed compared to water- or non-injected control trees. Overall disease suppression with streptomycin was lower than typically observed following spray applications to flowers. Trunk injection of oxytetracycline resulted in excellent control of shoot blight severity, suggesting that injection is a superior delivery method for this antibiotic. Injection of both ASM and PH resulted in the significant induction of PR-1, PR-2 and PR-8 protein genes in apple leaves indicating induction of systemic acquired resistance (SAR under field conditions. The time separating SAR induction and fire blight symptom suppression indicated that various defensive compounds within the SAR response were synthesized and accumulated in the canopy. ASM and PH suppressed fire blight even after cessation of induced gene expression. With the development of injectable formulations and optimization of doses and injection schedules, the injection of protective compounds could serve as an effective option for fire blight control.

  16. Hot topic - fire resistant clothing for electrical workers has no Canadian standard

    Energy Technology Data Exchange (ETDEWEB)

    Douglas, R

    1996-07-01

    Fabrics which could be used for protective clothing for electrical workers was discussed. In Canada there are no stringent clothing rules for the electrical industry, but in the United States, the Federal Occupational Safety and Health Administration (OSHA) have made protective clothing an issue within the industry. Dupont`s Nomex, Westex`s Indura, and Hoechst Celanese`s PBI fibres are among the materials which have been through a series of thermal protection tests and are based on proven materials which are now being applied to work wear. The testing standards cover the ignition of the basic materials, untreated cottons, wools, and the thermal protection of flame resistant materials. The final tests are based on high current arc tests conducted on the fabrics used in the industry. These tests are now being conducted at Ontario Hydro`s High Current Test Facility preliminary to a Canadian standard being formulated and proposed in the very near future. 2 figs.

  17. Hydrothermal Synthesis of Nanooctahedra MnFe₂O₄ onto the Wood Surface with Soft Magnetism, Fire Resistance and Electromagnetic Wave Absorption.

    Science.gov (United States)

    Wang, Hanwei; Yao, Qiufang; Wang, Chao; Ma, Zhongqing; Sun, Qingfeng; Fan, Bitao; Jin, Chunde; Chen, Yipeng

    2017-05-23

    In this study, nanooctahedra MnFe₂O₄ were successfully deposited on a wood surface via a low hydrothermal treatment by hydrogen bonding interactions. As-prepared MnFe₂O₄/wood composite (MW) had superior performance of soft magnetism, fire resistance and electromagnetic wave absorption. Among them, small hysteresis loops and low coercivity (magnetization-field curve of MW with saturation magnetization of 28.24 emu/g, indicating its excellent soft magnetism. The MW also exhibited a good fire-resistant property due to its initial burning time at 20 s; while only 6 s for the untreated wood (UW) in combustion experiments. Additionally, this composite revealed good electromagnetic wave absorption with a minimum reflection loss of -9.3 dB at 16.48 GHz. Therefore, the MW has great potential in the fields of special decoration and indoor electromagnetic wave absorbers.

  18. Effect of design parameters on performance of a top fired natural gas reformer

    International Nuclear Information System (INIS)

    Ebrahimi, Hadi; Mohammadzadeh, Jafar S. Soltan; Zamaniyan, Akbar; Shayegh, Flora

    2008-01-01

    A three-dimensional zone method was applied to an industrial fired heater of methane steam reforming reactor. Radiation heat transfer from all gases and surfaces inside the furnace was considered. Results from previous work and data of an industrial top fired furnace were used to validate the model. A maximum temperature in external reaction tube skin was obtained at about one third of the reactor length from top in the industrial furnace. Effect of important parameters such as emissivity, extinction coefficient, heat release pattern and flame angle on performance of the fired heater are presented. It was found that decreasing the extinction coefficients of combustion gases by 25% (from about 0.20 to 0.15) caused 2.6% rise in temperature of heat sink surfaces. It was demonstrated that the three-dimensional zone method developed in this work is simple, easy and flexible for modeling and simulation of the fired heaters

  19. Calibration of Resistance Factors Needed in the LRFD Design of Driven Piles

    Science.gov (United States)

    2009-05-01

    This research project presents the calibration of resistance factors for the Load and Resistance Factor Design (LRFD) method of driven : piles driven into Louisiana soils based on reliability theory. Fifty-three square Precast-Prestressed-Concrete (P...

  20. Design basis for resistance to shock and vibration

    International Nuclear Information System (INIS)

    Glass, R.E.; Gwinn, K.W.

    1989-01-01

    Sandia National Laboratories, in conjunction with its participation in the American National Standards Institute (ANSI) writing groups, has undertaken to provide an experimental and analytical basis for the design of components of radioactive materials packages to resist normal transport shock and vibration loads. Previous efforts have resulted in an overly conservative shock spectra description of the loads in the tie-downs and cask attachment points anticipated during normal shipment. The present effort is aimed at predicting the actual loads so that the design basis can be accurately determined. This goal is being accomplished with road simulator and over-the-road tests and the development of an analytical model. This model is used to parametrically evaluate and envelop the transportation systems' responses. The parameters to be varied include damping, stiffness, geometry, and cargo mass. The over-the-road tests provide operational data that are used to validate the selection of environments for the road simulator tests. The road simulator tests provide verification for the model. This verification is accomplished since the road simulator tests provide not only the system response which can be measured in over-the-road tests but also the system input. Finally, when the model has been verified, it can be used to vary parameters to envelop a wide range of normal transport conditions

  1. Tunable Noncollinear Antiferromagnetic Resistive Memory through Oxide Superlattice Design

    Science.gov (United States)

    Hoffman, Jason D.; Wu, Stephen M.; Kirby, Brian J.; Bhattacharya, Anand

    2018-04-01

    Antiferromagnets (AFMs) have recently gathered a large amount of attention as a potential replacement for ferromagnets (FMs) in spintronic devices due to their lack of stray magnetic fields, invisibility to external magnetic probes, and faster magnetization dynamics. Their development into a practical technology, however, has been hampered by the small number of materials where the antiferromagnetic state can be both controlled and read out. We show that by relaxing the strict criterion on pure antiferromagnetism, we can engineer an alternative class of magnetic materials that overcome these limitations. This is accomplished by stabilizing a noncollinear magnetic phase in LaNiO3 /La2 /3Sr1 /3MnO3 superlattices. This state can be continuously tuned between AFM and FM coupling through varying the superlattice spacing, strain, applied magnetic field, or temperature. By using this alternative "knob" to tune magnetic ordering, we take a nanoscale materials-by-design approach to engineering ferromagneticlike controllability into antiferromagnetic synthetic magnetic structures. This approach can be used to trade-off between the favorable and unfavorable properties of FMs and AFMs when designing realistic resistive antiferromagnetic memories. We demonstrate a memory device in one such superlattice, where the magnetic state of the noncollinear antiferromagnet is reversibly switched between different orientations using a small magnetic field and read out in real time with anisotropic magnetoresistance measurements.

  2. 1024x1024 resistive emitter array design and fabrication status

    Science.gov (United States)

    Bryant, Paul T.; Oleson, Jim; McHugh, Stephen W.; Beuville, Eric; Schlesselmann, John D.; Woolaway, James T.; Barskey, Steve; Solomon, Steven L.; Joyner, Thomas W.

    2002-07-01

    Santa Barbara Infrared (SBIR) is producing a high performance 1,024 x 1,024 Large Format Resistive emitter Array (LFRA) for use in the next generation of IR Scene Projectors (IRSPs). LFRA requirements were developed through close cooperation with the Tri-Service IR Scene Projector working group, and through detailed trade studies sponsored by the OSD Central T&E Investment Program (CTEIP) and a Phase I US Navy Small Business Innovative Research (SBIR) contract. The CMOS Read-In Integrated Circuit (RIIC) is being designed by SBIR and Indigo Systems under a Small Business Innovative Research (SBIR) contract. Performance and features include 750 K MWIR maximum apparent temperature, 5 ms radiance rise time, 200 Hz full frame update, and 400 Hz window mode operation. Ten 8-inch CMOS wafers will be fabricated and characterized in mid-2002, followed by emitter fabrication in late 2002. This paper discusses array performance, requirements flow-down, array design, fabrication of 2 X 2-inch CMOS devices, and plans for subsequent RIIC wafer test and emitter pixel fabrication.

  3. Design basis for resistance to shock and vibration

    International Nuclear Information System (INIS)

    Glass, R.E.; Gwinn, K.W.

    1989-01-01

    Sandia National Laboratories, in conjunction with its participation in the American National Standards Institute (ANSI) writing groups, has undertaken to provide an experimental and analytical basis for the design of components of radioactive materials packages to resist normal transport shock and vibration loads. Previous efforts have resulted in an overly conservative shock spectra description of the loads in the tie-downs and cask attachment points anticipated during normal shipment. The present effort is aimed at predicting the actual loads so that the design basis can be accurately determined. This goal is being accomplished with road simulator and over-the-road tests and the development of an analytical model. This model is used to parametrically evaluate and envelop the transportation systems responses. The parameters to be varied include damping, stiffness, geometry, and cargo mass. The over-the-road tests provide operational data that are used to validate the selection of environments for the road simulator tests. The road simulator tests provide verification for the model. This verification is accomplished since the road simulator tests provide not only the system response which can be measured in over-the-road tests but also the system input. Finally, when the model has been verified, it can be used to vary parameters to envelope a wide range of normal transport conditions

  4. Review of the IAEA fire symposium

    International Nuclear Information System (INIS)

    Fischer, J.

    1991-01-01

    The IAEA Symposium on Fire Protection and Fire Fighting in Nuclear Installations covered a large scope in the field in order to provide the opportunity for screening all aspects of present technology, research and development, standardization, licensing and fire fighting practices. Although application to any nuclear facility was within its scope, the majority of presentations concerned nuclear power plants. The approach to fire protection is the classical one in all plant designs: reduction of fire loads, appropriate zoning, manual and automatic extinguishment. However, methods of analysis and consequence prediction are changing. Computerized fire modelling is becoming a powerful tool in this area; probabilistic analytical methods are being improved, though they are not yet used widely for fire hazards. Differences in opinion were revealed in the definition of barrier resistance, the prediction of cable insulation behaviour and the optimal design of extinguishing systems. Greater international co-operation, especially in these areas, may be a good way of optimizing results with limited resources. Discussion contributions showed interest in exchange of experience in more specialized topics and encouraged the IAEA to increase its activity in the area of fire protection. (orig.)

  5. Design of online testing system of material radiation resistance

    International Nuclear Information System (INIS)

    Wan Junsheng; He Shengping; Gao Xinjun

    2014-01-01

    The capability of radiation resistance is important for some material used in some specifically engineering fields. It is the same principal applied in all existing test system that compares the performance parameter after radiation to evaluate material radiation resistance. A kind of new technique on test system of material radiation resistance is put forward in this paper. Experimentation shows that the online test system for material radiation resistance works well and has an extending application outlook. (authors)

  6. Fire safety

    International Nuclear Information System (INIS)

    Keski-Rahkonen, O.; Bjoerkman, J.; Hostikka, S.; Mangs, J.; Huhtanen, R.; Palmen, H.; Salminen, A.; Turtola, A.

    1998-01-01

    According to experience and probabilistic risk assessments, fires present a significant hazard in a nuclear power plant. Fires may be initial events for accidents or affect safety systems planned to prevent accidents and to mitigate their consequences. The project consists of theoretical work, experiments and simulations aiming to increase the fire safety at nuclear power plants. The project has four target areas: (1) to produce validated models for numerical simulation programmes, (2) to produce new information on the behavior of equipment in case of fire, (3) to study applicability of new active fire protecting systems in nuclear power plants, and (4) to obtain quantitative knowledge of ignitions induced by important electric devices in nuclear power plants. These topics have been solved mainly experimentally, but modelling at different level is used to interpret experimental data, and to allow easy generalisation and engineering use of the obtained data. Numerical fire simulation has concentrated in comparison of CFD modelling of room fires, and fire spreading on cables on experimental data. So far the success has been good to fair. A simple analytical and numerical model has been developed for fire effluents spreading beyond the room of origin in mechanically strongly ventilated compartments. For behaviour of equipment in fire several full scale and scaled down calorimetric experiments were carried out on electronic cabinets, as well as on horizontal and vertical cable trays. These were carried out to supply material for CFD numerical simulation code validation. Several analytical models were developed and validated against obtained experimental results to allow quick calculations for PSA estimates as well as inter- and extrapolations to slightly different objects. Response times of different commercial fire detectors were determined for different types of smoke, especially emanating from smoldering and flaming cables to facilitate selection of proper detector

  7. Fire retardant formulations

    DEFF Research Database (Denmark)

    2017-01-01

    The present invention relates to compositions where a substrate is liable to catch fire such as bituminous products, paints, carpets or the like. The invention relates to a composition comprising 40-95 weight % of a substrate to be rendered fire resistant such as bituminous material or paint......, carpets which substrate is mixed with 5-60 weight % of a fire retardant component. The invention relates to a fire retardant component comprising or being constituted of attapulgite, and a salt being a source of a blowing or expanding agent, where the attapulgite and the salt are electrostatically...... connected by mixing and subjecting the mixture of the two components to agitation. Also, the invention relates to compositions comprising 40-95 weight % of a substrate to be rendered fire resistant mixed with 5-60 weight % of a fire retardant according to claim 1 or 2, which fire retardant component...

  8. Fire Safety Consideration in the Pre-conceptual Design State of Pyro-Facillity

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Hong Rae; Seo, Seok Jun; Lee, Hyo Jik [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The government, in order to solve this problem, has organized a public engagement committee and is searching for a solution. To use sustainable nuclear energy, our country is also pursuing research and development of fast breeder reactor and pyroprocessing technology in accordance with the international movement of spent fuel recycling and efforts towards nuclear non-proliferation which is centered on the development and demonstration of recycling spent fuel and fast breeder reactors. Pyro-facility has different features with nuclear power plant. In the pyroprocess, chemical and electrochemical separation were took place in the hot cells and material at risk (MAR) is distributed in many working areas. In this paper, we conducted the fire modeling of hot cells to see the stability of pyrophoric materials which is considered as one of the potential hazardous materials in the main process cell. Based on modeling results, consideration of fire safety pyrofacility will be discussed. We performed preliminary hazard analysis for pyrofacility and summarized potential fire hazard. Pyrophoric material fire is the dominant hazard in the main process hot cell and fire modeling of cable tray in the cell was analyzed to see the stability of pyrophoric materials. Analysis results clearly shows that pyrophoric materials are prone to be affected.

  9. Engineering fire blight resistance into the apple cultivar 'Gala' using the FB_MR5 CC-NBS-LRR resistance gene of Malus × robusta 5.

    Science.gov (United States)

    Broggini, Giovanni A L; Wöhner, Thomas; Fahrentrapp, Johannes; Kost, Thomas D; Flachowsky, Henryk; Peil, Andreas; Hanke, Maria-Viola; Richter, Klaus; Patocchi, Andrea; Gessler, Cesare

    2014-08-01

    The fire blight susceptible apple cultivar Malus × domestica Borkh. cv. 'Gala' was transformed with the candidate fire blight resistance gene FB_MR5 originating from the crab apple accession Malus × robusta 5 (Mr5). A total of five different transgenic lines were obtained. All transgenic lines were shown to be stably transformed and originate from different transgenic events. The transgenic lines express the FB_MR5 either driven by the constitutive CaMV 35S promoter and the ocs terminator or by its native promoter and terminator sequences. Phenotyping experiments were performed with Mr5-virulent and Mr5-avirulent strains of Erwinia amylovora, the causal agent of fire blight. Significantly less disease symptoms were detected on transgenic lines after inoculation with two different Mr5-avirulent E. amylovora strains, while significantly more shoot necrosis was observed after inoculation with the Mr5-virulent mutant strain ZYRKD3_1. The results of these experiments demonstrated the ability of a single gene isolated from the native gene pool of apple to protect a susceptible cultivar from fire blight. Furthermore, this gene is confirmed to be the resistance determinant of Mr5 as the transformed lines undergo the same gene-for-gene interaction in the host-pathogen relationship Mr5-E. amylovora. © 2014 Society for Experimental Biology, Association of Applied Biologists and John Wiley & Sons Ltd.

  10. Resistive wall mode active control physics design for KSTAR

    International Nuclear Information System (INIS)

    Park, Y. S.; Sabbagh, S. A.; Bialek, J. M.; Berkery, J. W.; Bak, J. G.; Lee, S. G.; Oh, Y. K.

    2014-01-01

    As KSTAR H-mode operation approaches the region where the resistive wall mode (RWM) can be unstable, an important issue for future long pulse, high beta plasma operation is to evaluate RWM active feedback control performance using a planned active/passive RWM stabilization system on the device. In particular, an optimal design of feedback sensors allows mode stabilization up to the highest achievable β N close to the ideal with-wall limit, β N wall , with reduced control power requirements. The computed ideal n = 1 mode structure from the DCON code has been input to the VALEN-3D code to calculate the projected performance of an active RWM control system in the KSTAR three-dimensional conducting structure device geometry. Control performance with the midplane locked mode detection sensors, off-midplane saddle loops, and magnetic pickup coils is examined. The midplane sensors measuring the radial component of the mode perturbation is found to be strongly affected by the wall eddy current. The off-axis saddle loops with proper compensation of the prompt applied field are computed to provide stabilization at β N up to 86% of β N wall but the low RWM amplitude computed in the off-axis regions near the sensors can produce a low signal-to-noise ratio. The required control power and bandwidth are also estimated with varied noise levels in the feedback sensors. Further improvements have been explored by examining a new RWM sensor design motivated by the off-midplane poloidal magnetic field sensors in NSTX. The new sensors mounted off of the copper passive stabilizer plates near the device midplane show a clear advantage in control performance corresponding to achieving 99% of β N wall without the need of compensation of the prompt field. The result shows a significant improvement of RWM feedback stabilization using the new sensor set which motivates a future feedback sensor upgrade

  11. Seismic resistant design of a nuclear category I earth dam

    International Nuclear Information System (INIS)

    Vaidya, N.R.; Ries, E.R.; Kissenpfennig, J.F.

    1975-01-01

    An integral part of many nuclear power plants is the ultimate heat sink (UHS); the purpose of which is to retain and deliver a supply of service water to the plant when water from the primary circulating water system is not available. The earth dam described herein is designed to retain the reservoir for the UHS of a nuclear power plant in Southern Europe. The usual pseudo-static analysis is only as good as the estimate for the seismic coefficient used to compute an equivalent horizontal static force on a potential sliding mass. In view of the earth dam considered herein, a more accurate computation of the seismic coefficients is to be made. A two-dimensional dynamic finite element analysis is made to predict the response of the earth dam to a Safe Shutdown Earthquake excitation which is in the form of a time history of accelerations appropriately deconvoluted from the surficial time history and applied at the base of the model. The material properties such as shear modulus and damping are adjusted to be compatible with the level of strain obtained. Thus, non-linear behavior of soil is considered in the analysis and a more realistic response is predicted. Acceleration and stress are determined throughout the dam and are used to compute a seismic coefficient for a pseudo-static stability analysis and the dynamic strength to stress ratios at several points in the body of the dam. The need to design the dam to resist a progressive erosion accident resulting from postulated concentrated leaks is discussed. This may be accomplished by providing a wide, well graded core protected by wide transition cores also heavily compacted

  12. A study of the evolution of rust on Mo–Cu-bearing fire-resistant steel submitted to simulated atmospheric corrosion

    International Nuclear Information System (INIS)

    Hao Long; Zhang Sixun; Dong Junhua; Ke Wei

    2012-01-01

    Highlights: ► The rusting evolution of a Mo–Cu-bearing fire-resistant steel in a simulated industrial atmosphere was investigated. ► The rusting evolution of the steel is related to the rust composition, structure, and electrochemical characteristics. ► Increased content of α-FeOOH and decreased γ-FeOOH and Fe 3 O 4 indicate the enhanced resistance of the rust. ► Mo and Cu are involved in the formation of molybdate and Cu(I)-bearing compounds in the rust. - Abstract: The corrosion evolution of a Mo–Cu-bearing fire-resistant steel in a simulated industrial atmosphere was investigated by corrosion weight gain, XRD, EPMA, XPS, and polarization curves. The results indicate that the corrosion kinetics is closely related to the rust composition and electrochemical properties. As the corrosion proceeds, the relative content of γ-FeOOH and Fe 3 O 4 decreases and α-FeOOH increases, and the rust layer becomes compact and adherent to steel substrate. Molybdenum and copper enrich in the inner rust layer, especially at the bottom of the corrosion nest, forming non-soluble molybdate and Cu(I)-bearing compounds responsible for enhanced corrosion resistance of the rust layer.

  13. Safety considerations and countermeasures against fire and explosion at an HTGR-hydrogen production system. Proposal of safety design concept

    International Nuclear Information System (INIS)

    Nishihara, T.; Hada, K.; Shibata, T.; Shiozawa, S.

    1996-01-01

    Establishment of safety design concept and countermeasures against fire and explosion accidents is among key safety-related issues in an HTGR-hydrogen production system. We propose the different safety design concepts depending upon the origin of fire and explosion which may happen in the HTGR-hydrogen production plant. Against fire and explosion originated outside the reactor building (R/B), namely in the area of hydrogen production plant, the safety design concept is primarily to take a safe distance for preventing the damage on safety-related items or a proof wall if necessary. Because the hydrogen production plant is designed in the same safety level as a conventional chemical plant. The safe distance is proposed to limit an incident overpressure to 10 kPa so as not to suffer any damage on the items and to limit a wall-averaged temperature of concrete structures of the R/B to 175degC according to the current regulation. On the other hand, against a potential possibility of explosion originated inside the R/B, the safety design concept is to minimize the possibility of explosion low enough to assume no occurrence inside the R/B. That is, the measure is to exclude a simultaneous failure of a secondary helium piping and an endothermic chemical reactor. Furthermore, in severe accident condition in which the explosion may be postulated a priori, an incidental overpressure of explosion inside the reactor containment vessel (C/V) should be limited so as not to fail the C/V through restricting the amount of combustible gas ingress into the C/V by means of a combination of C/V isolation valve installed in the helium piping and emergency shut off valve in the process feed gas line. (author)

  14. Fire safety of wood construction

    Science.gov (United States)

    Robert H. White; Mark A. Dietenberger

    2010-01-01

    Fire safety is an important concern in all types of construction. The high level of national concern for fire safety is reflected in limitations and design requirements in building codes. These code requirements and related fire performance data are discussed in the context of fire safety design and evaluation in the initial section of this chapter. Because basic data...

  15. Simulating forest fuel and fire risk dynamics across landscapes--LANDIS fuel module design

    Science.gov (United States)

    Hong S. He; Bo Z. Shang; Thomas R. Crow; Eric J. Gustafson; Stephen R. Shifley

    2004-01-01

    Understanding fuel dynamics over large spatial (103-106 ha) and temporal scales (101-103 years) is important in comprehensive wildfire management. We present a modeling approach to simulate fuel and fire risk dynamics as well as impacts of alternative fuel treatments. The...

  16. An algorithm to help design fire simulation and other data base work

    Science.gov (United States)

    Romain Mees

    1974-01-01

    The data necessary for fire simulation may be made available through an algorithm based on tracing of boundaries composed of straight-line segments. Useful assumptions are that if a closed boundary does not contain a given point, then any other closed boundary contained within the former one does not contain the location; and that a given location will be contained in...

  17. Analysis of Moisture Evaporation from Underwear Designed for Fire-Fighters

    Directory of Open Access Journals (Sweden)

    Elena Onofrei

    2015-03-01

    Full Text Available In this study we analysed the effect of moisture on the thermal protective performance of fire-fighter clothing in case of routine fire-fighting conditions. In the first stage of this research we investigated simultaneous heat and moisture transfer through a single-layer fabric, used as underwear for fire-fighters, at different moisture conditions. In the second stage of the study, the underwear in dry and wet state was tested together with protective clothing systems for fire-fighter consisting of three or four layers. It was found that during the evaporation of the moisture, a temperature plateau appeared during which temperatures hardly rose. The energy consumption used for the phase change of moisture located in the assembly dominated the heat transfer process as long as there was moisture present. As soon as all water had evaporated, the temperatures approached the temperatures measured for dry samples. The moisture within the clothing assembly did not lead to increased temperatures compared with the measurements with dry samples. This research has confirmed that moisture can positively affect the thermal protection of a clothing system.

  18. 75 FR 20516 - Special Conditions: Cirrus Design Corporation, Model SF50; Fire Extinguishing for Upper Aft...

    Science.gov (United States)

    2010-04-20

    ... defined in Sec. 11.19, under Sec. 11.38 and they become part of the type certification basis under Sec. 21... requiring and defining engine compartment fire extinguishing systems already exist for part 23 commuter... structure or the fuselage. In essence the engine could burn off of the pylon and not adversely compromise...

  19. Resistance identification and rational process design in Capacitive Deionization

    NARCIS (Netherlands)

    Dykstra, Jouke; Zhao, R.; Biesheuvel, P.M.; Wal, van der A.

    2016-01-01

    Capacitive Deionization (CDI) is an electrochemical method for water desalination employing porous carbon electrodes. To enhance the performance of CDI, identification of electronic and ionic resistances in the CDI cell is important. In this work, we outline a method to identify these resistances.

  20. The effects of model composition design choices on high-fidelity simulations of motoneuron recruitment and firing behaviors

    Science.gov (United States)

    Allen, John M.; Elbasiouny, Sherif M.

    2018-06-01

    Objective. Computational models often require tradeoffs, such as balancing detail with efficiency; yet optimal balance should incorporate sound design features that do not bias the results of the specific scientific question under investigation. The present study examines how model design choices impact simulation results. Approach. We developed a rigorously-validated high-fidelity computational model of the spinal motoneuron pool to study three long-standing model design practices which have yet to be examined for their impact on motoneuron recruitment, firing rate, and force simulations. The practices examined were the use of: (1) generic cell models to simulate different motoneuron types, (2) discrete property ranges for different motoneuron types, and (3) biological homogeneity of cell properties within motoneuron types. Main results. Our results show that each of these practices accentuates conditions of motoneuron recruitment based on the size principle, and minimizes conditions of mixed and reversed recruitment orders, which have been observed in animal and human recordings. Specifically, strict motoneuron orderly size recruitment occurs, but in a compressed range, after which mixed and reverse motoneuron recruitment occurs due to the overlap in electrical properties of different motoneuron types. Additionally, these practices underestimate the motoneuron firing rates and force data simulated by existing models. Significance. Our results indicate that current modeling practices increase conditions of motoneuron recruitment based on the size principle, and decrease conditions of mixed and reversed recruitment order, which, in turn, impacts the predictions made by existing models on motoneuron recruitment, firing rate, and force. Additionally, mixed and reverse motoneuron recruitment generated higher muscle force than orderly size motoneuron recruitment in these simulations and represents one potential scheme to increase muscle efficiency. The examined model

  1. Calibration of resistance factors for drilled shafts for the new FHWA design method.

    Science.gov (United States)

    2013-01-01

    The Load and Resistance Factor Design (LRFD) calibration of deep foundation in Louisiana was first completed for driven piles (LTRC Final Report 449) in May 2009 and then for drilled shafts using 1999 FHWA design method (ONeill and Reese method) (...

  2. Taxonomically-linked growth phenotypes during arsenic stress among arsenic resistant bacteria isolated from soils overlying the Centralia coal seam fire.

    Science.gov (United States)

    Dunivin, Taylor K; Miller, Justine; Shade, Ashley

    2018-01-01

    Arsenic (As), a toxic element, has impacted life since early Earth. Thus, microorganisms have evolved many As resistance and tolerance mechanisms to improve their survival outcomes given As exposure. We isolated As resistant bacteria from Centralia, PA, the site of an underground coal seam fire that has been burning since 1962. From a 57.4°C soil collected from a vent above the fire, we isolated 25 unique aerobic As resistant bacterial strains spanning seven genera. We examined their diversity, resistance gene content, transformation abilities, inhibitory concentrations, and growth phenotypes. Although As concentrations were low at the time of soil collection (2.58 ppm), isolates had high minimum inhibitory concentrations (MICs) of arsenate and arsenite (>300 mM and 20 mM respectively), and most isolates were capable of arsenate reduction. We screened isolates (PCR and sequencing) using 12 published primer sets for six As resistance genes (AsRGs). Genes encoding arsenate reductase (arsC) and arsenite efflux pumps (arsB, ACR3(2)) were present, and phylogenetic incongruence between 16S rRNA genes and AsRGs provided evidence for horizontal gene transfer. A detailed investigation of differences in isolate growth phenotypes across As concentrations (lag time to exponential growth, maximum growth rate, and maximum OD590) showed a relationship with taxonomy, providing information that could help to predict an isolate's performance given As exposure in situ. Our results suggest that microbiological management and remediation of environmental As could be informed by taxonomically-linked As tolerance, potential for resistance gene transferability, and the rare biosphere.

  3. Highly Flexible, Fire Resistant HybridSil Foams for Next Generation Fireproofing, Insulation, and Energy Absorption NASA Applications, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this Phase I STTR program is to adapt NanoSonic's HybridSil™ nanocomposite technology for the creation of next generation highly flexible, fire...

  4. Review of biomass fired space heating/domestic hot water boilers' application, operation and design parameters

    International Nuclear Information System (INIS)

    1997-01-01

    Monitoring exercises have been carried out for ETSU, by a number of contractors, on a number of wood fired heating schemes; feasibility studies on proposed schemes have also been carried out. Monitoring reports and feasibility studies have been reviewed to try and establish the suitability and economic viability of the various types of plant used (or proposed) and their application. Of the sixteen schemes reviewed just over 30% showed a reasonable return on the incremental capital cost of plant compared to gas oil fired plant. These schemes had one or more of the following attributes: - Low wood fuel cost -Long operating hours -Relatively low incremental capital cost of wood plant over gas oil plant. Small systems with low operating hours (e.g. short weekday occupancy premises, like schools) and relatively high incremental operating and maintenance costs and capital costs exhibited no advantage over equivalent fossil fuel fired plant. The unit fuel cost advantage to wood, in these cases, was insufficient to outweigh the increased O and M and capital costs, because of the comparatively low annual fuel consumption. Most of the plants reviewed had low thermal efficiencies due to the simplicity of the fuel to air control systems and the wide range of heating demand over which they had to operate. The former can be increased by improved combustion control systems and the latter by correct sizing of boilers and/or the installation of hybrid systems. (Author)

  5. FireProt: Energy- and Evolution-Based Computational Design of Thermostable Multiple-Point Mutants.

    Science.gov (United States)

    Bednar, David; Beerens, Koen; Sebestova, Eva; Bendl, Jaroslav; Khare, Sagar; Chaloupkova, Radka; Prokop, Zbynek; Brezovsky, Jan; Baker, David; Damborsky, Jiri

    2015-11-01

    There is great interest in increasing proteins' stability to enhance their utility as biocatalysts, therapeutics, diagnostics and nanomaterials. Directed evolution is a powerful, but experimentally strenuous approach. Computational methods offer attractive alternatives. However, due to the limited reliability of predictions and potentially antagonistic effects of substitutions, only single-point mutations are usually predicted in silico, experimentally verified and then recombined in multiple-point mutants. Thus, substantial screening is still required. Here we present FireProt, a robust computational strategy for predicting highly stable multiple-point mutants that combines energy- and evolution-based approaches with smart filtering to identify additive stabilizing mutations. FireProt's reliability and applicability was demonstrated by validating its predictions against 656 mutations from the ProTherm database. We demonstrate that thermostability of the model enzymes haloalkane dehalogenase DhaA and γ-hexachlorocyclohexane dehydrochlorinase LinA can be substantially increased (ΔTm = 24°C and 21°C) by constructing and characterizing only a handful of multiple-point mutants. FireProt can be applied to any protein for which a tertiary structure and homologous sequences are available, and will facilitate the rapid development of robust proteins for biomedical and biotechnological applications.

  6. FireProt: Energy- and Evolution-Based Computational Design of Thermostable Multiple-Point Mutants.

    Directory of Open Access Journals (Sweden)

    David Bednar

    2015-11-01

    Full Text Available There is great interest in increasing proteins' stability to enhance their utility as biocatalysts, therapeutics, diagnostics and nanomaterials. Directed evolution is a powerful, but experimentally strenuous approach. Computational methods offer attractive alternatives. However, due to the limited reliability of predictions and potentially antagonistic effects of substitutions, only single-point mutations are usually predicted in silico, experimentally verified and then recombined in multiple-point mutants. Thus, substantial screening is still required. Here we present FireProt, a robust computational strategy for predicting highly stable multiple-point mutants that combines energy- and evolution-based approaches with smart filtering to identify additive stabilizing mutations. FireProt's reliability and applicability was demonstrated by validating its predictions against 656 mutations from the ProTherm database. We demonstrate that thermostability of the model enzymes haloalkane dehalogenase DhaA and γ-hexachlorocyclohexane dehydrochlorinase LinA can be substantially increased (ΔTm = 24°C and 21°C by constructing and characterizing only a handful of multiple-point mutants. FireProt can be applied to any protein for which a tertiary structure and homologous sequences are available, and will facilitate the rapid development of robust proteins for biomedical and biotechnological applications.

  7. The economics of fire protection

    CERN Document Server

    Ramachandran, Ganapathy

    2003-01-01

    This important new book, the first of its kind in the fire safety field, discusses the economic problems faced by decision-makers in the areas of fire safety and fire precautions. The author considers the theoretical aspects of cost-benefit analysis and other relevant economic problems with practical applications to fire protection systems. Clear examples are included to illustrate these techniques in action. The work covers: * the performance and effectiveness of passive fire protection measures such as structural fire resistance and means of escape facilities, and active systems such as sprinklers and detectors * the importance of educating for better understanding and implementation of fire prevention through publicity campaigns and fire brigade operations * cost-benefit analysis of fire protection measures and their combinations, taking into account trade-offs between these measures. The book is essential reading for consultants and academics in construction management, economics and fire safety, as well ...

  8. Documentation for Calculations of Standard Fire Resistance of Slabs and Walls of Concrete with Expanded Clay Aggregate

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl

    A number of full-scale tests are made in order to document calculation methods for fire-exposed slabs and walls derived during a previous project on fire exposed light-weight aggregate concrete constructions. The calculation methods are derived, and thus have a logical connection with the calcula......A number of full-scale tests are made in order to document calculation methods for fire-exposed slabs and walls derived during a previous project on fire exposed light-weight aggregate concrete constructions. The calculation methods are derived, and thus have a logical connection...... with the calculation methods used for other load cases. In addition the methods are shown to be valid for heavy concrete constructions by cooperation with tests for beams and columns, and a few slabs and walls. The two test series phase 1 and 2 of this report can therefore be seen as a necessary supplement to show...... that the methods are applicable for slabs and walls of light weight aggregate concrete. It is shown that the temperatures for standard fire exposed cross sections can be calculated, that the ultimate moment capacity can be calculated for slabs, and that the anchorage capacity and the shear tension capacity can...

  9. Tunnel fire dynamics

    CERN Document Server

    Ingason, Haukur; Lönnermark, Anders

    2015-01-01

    This book covers a wide range of issues in fire safety engineering in tunnels, describes the phenomena related to tunnel fire dynamics, presents state-of-the-art research, and gives detailed solutions to these major issues. Examples for calculations are provided. The aim is to significantly improve the understanding of fire safety engineering in tunnels. Chapters on fuel and ventilation control, combustion products, gas temperatures, heat fluxes, smoke stratification, visibility, tenability, design fire curves, heat release, fire suppression and detection, CFD modeling, and scaling techniques all equip readers to create their own fire safety plans for tunnels. This book should be purchased by any engineer or public official with responsibility for tunnels. It would also be of interest to many fire protection engineers as an application of evolving technical principles of fire safety.

  10. Fire Perimeters

    Data.gov (United States)

    California Natural Resource Agency — The Fire Perimeters data consists of CDF fires 300 acres and greater in size and USFS fires 10 acres and greater throughout California from 1950 to 2003. Some fires...

  11. Fire History

    Data.gov (United States)

    California Natural Resource Agency — The Fire Perimeters data consists of CDF fires 300 acres and greater in size and USFS fires 10 acres and greater throughout California from 1950 to 2002. Some fires...

  12. Fire tests and their relevance

    International Nuclear Information System (INIS)

    Malhotra, H.L.

    1984-01-01

    Background information is provided about the nature of fire tests in general, not specifically designed for testing nuclear flasks. Headings are: brief history (including various temperature/time fire curves); the current position; types of tests; validation of fire tests; fire safety system. (U.K.)

  13. Off-design thermodynamic performances on typical days of a 330 MW solar aided coal-fired power plant in China

    International Nuclear Information System (INIS)

    Peng, Shuo; Hong, Hui; Wang, Yanjuan; Wang, Zhaoguo; Jin, Hongguang

    2014-01-01

    Highlights: • Optical loss and heat loss of solar field under different turbine load were investigated. • Off-design thermodynamic feature was disclosed by analyzing several operational parameters. • Possible schemes was proposed to improve the net solar-to-electricity efficiency. - Abstract: The contribution of mid-temperature solar thermal power to improve the performance of coal-fired power plant is analyzed in the present paper. In the solar aided coal-fired power plant, solar heat at <300 °C is used to replace the extracted steam from the steam turbine to heat the feed water. In this way, the steam that was to be extracted could consequently expand in the steam turbine to boost output power. The advantages of a solar aided coal-fired power plant in design condition have been discussed by several researchers. However, thermodynamic performances on off-design operation have not been well discussed until now. In this paper, a typical 330 MW coal-fired power plant in Sinkiang Province of China is selected as the case study to demonstrate the advantages of the solar aided coal-fired power plant under off-design conditions. Hourly thermodynamic performances are analyzed on typical days under partial load. The effects of several operational parameters, such as solar irradiation intensity, incident angle, flow rate of thermal oil, on the performance of solar field efficiency and net solar-to-electricity efficiency were examined. Possible schemes have been proposed for improving the solar aided coal-fired power plant on off-design operation. The results obtained in the current study could provide a promising approach to solve the poor thermodynamic performance of solar thermal power plant and also offer a basis for the practical operation of MW-scale solar aided coal-fired power plant

  14. Overview of fire curtains in construction

    Directory of Open Access Journals (Sweden)

    Nedryshkin Oleg

    2016-01-01

    Full Text Available A fire curtain is use where, if there is a fire, it is necessary to create a temporary barrier within an opening, which seals off the area on fire. The curtain descends and prevents any fire and smoke from spreading from one area to another. It also allows people access to protected escape routes without any loss of fire resistance. The paper aims to presents the results of analysis of the scientific literature on the subject of fire curtains.

  15. Proposal of safety design methodologies for an HTGR-hydrogen production system. Mainly on countermeasures against fire and explosion

    International Nuclear Information System (INIS)

    Nishihara, Tetsuo; Hada, Kazuhiko; Shiozawa, Syusaku

    1996-03-01

    Among key issues of the safety design for an HTGR-hydrogen production system is to ensure the safety of the nuclear reactor against fire and explosion accidents in the hydrogen production plant. The fire and explosion accidents in the hydrogen production plant are categorized into the following two cases; Accidents inside the reactor building (R/B) and accidents outside the R/B. Against accidents inside the R/B, the proposed safety design concept is to prevent the occurrence of the accidents based on the defence in depth concept. The piping system and/or heat transfer tubes which have the potential possibility of combustible materials ingress into the R/B due to the failure are designed at the highest aseismic level to prevent the failure against severe earthquake. Even if the failure occurs, the piping trench and related compartments are fulfilled with nitrogen so as to prevent the occurrence of accidents. The proposed safety design concept for the accidents outside the R/B is the mitigation of effects of accidents. Proposed countermeasures is to take the safe distance between the hydrogen production plant and the items important to safety in the nuclear plant. We showed that the anticipated accidents to estimate the safe distance are large scale pool burning, fireball, pressure vessel burst and vapor cloud explosion. Especially, new estimating concept to establish the safe distance is proposed for the vapor cloud explosion. To reduce the safe distance, we proposed the underground non-pressurized storage tank and ventilation system for the storage of large amount of combustible liquid. (author). 61 refs

  16. A dual fired downdraft gasifier system to produce cleaner gas for power generation: Design, development and performance analysis

    International Nuclear Information System (INIS)

    Raman, P.; Ram, N.K.; Gupta, Ruchi

    2013-01-01

    The existing biomass gasifier systems have several technical challenges, which need to be addressed. They are reduction of impurities in the gas, increasing the reliability of the system, easy in operation and maintenance. It is also essential to have a simple design of gasifier system for power generation, which can work even in remote locations. A dual fired downdraft gasifier system was designed to produce clean gas from biomass fuel, used for electricity generation. This system is proposed to overcome a number of technical challenges. The system is equipped with dry gas cleaning and indirect gas cooling equipment. The dry gas cleaning system completely eliminates wet scrubbers that require large quantities of water. It also helps to do away with the disposal issues with the polluted water. With the improved gasifier system, the tar level in the raw gas is less than 100 mg Nm −3 .Cold gas efficiency has improved to 89% by complete gasification of biomass and recycling of waste heat into the reactor. Several parameters, which are considered in the design and development of the reactors, are presented in detail with their performance indicators. - Highlights: • Hot air injection in dual fired reactor reduces the tar content to less than 100 mg Nm −3 . • In clean gas the tar content is 35 mg Nm −3 and the dust content is nil. • The specific gasification rate is 2.8 Nm 3 kg −1 of fuel wood and cold gas efficiency is 89.7%. • CV of the gas: 5.3 MJ Nm −3 , SFC: 1.1 kg kWh −1 and wood to power efficiency: 21%. • Cold gas efficiency is improved by optimizing the reactor's design and recycling the waste heat from hot gas

  17. Design of an experiment to measure the fire exposure of radioactive materials packages aboard container cargo ships

    International Nuclear Information System (INIS)

    Koski, J.A.

    1997-11-01

    The test described in this paper is intended to measure the typical accident environment for a radioactive materials package in a fire aboard a container cargo ship. A stack of nine used standard cargo containers will be variously loaded with empty packages, simulated packages and combustible cargo and placed over a large hydrocarbon pool fire of one hour duration. Both internal and external fire container fire environments typical of on-deck stowage will be measured as well as the potential for container to container fire spread. With the use of the inverse heat conduction calculations, the local heat transfer to the simulated packages can be estimated from thermocouple data. Data recorded will also provide information on fire durations in each container, fire intensity and container to container fire spread characteristics

  18. Building configuration and seismic design: The architecture of earthquake resistance

    Science.gov (United States)

    Arnold, C.; Reitherman, R.; Whitaker, D.

    1981-05-01

    The architecture of a building in relation to its ability to withstand earthquakes was determined. Aspects of round motion which are significant to building behavior are discussed. Results of a survey of configuration decisions that affect the performance of buildings with a focus on the architectural aspects of configuration design are provided. Configuration derivation, building type as it relates to seismic design, and seismic design, and seismic issues in the design process are examined. Case studies of the Veterans' Administration Hospital in Loma Linda, California, and the Imperial Hotel in Tokyo, Japan, are presented. The seismic design process is described paying special attention to the configuration issues. The need is stressed for guidelines, codes, and regulations to ensure design solutions that respect and balance the full range of architectural, engineering, and material influences on seismic hazards.

  19. RESEARCH OF HEAT-RESISTANT CONCRETE ON THE BASIS OF BASALT FILLER FOR CONCRETING OF METAL DESIGNS

    Directory of Open Access Journals (Sweden)

    R. M. Curbanov

    2013-01-01

    Full Text Available Expediency of use of heat-resistant concrete locates in article on the basis of a basalt filler. It is thin a ground additive promotes increase in power of internal friction between material particles. With increase in power of internal friction between particles viscosity knitting increases and as a result ryazmyagcheniye temperature under loading increases and fire resistance of a material increases

  20. Mapping fusiform rust resistance genes within a complex mating design of loblolly pine

    Science.gov (United States)

    Tania Quesada; Marcio F.R. Resende Jr.; Patricio Munoz; Jill L. Wegrzyn; David B. Neale; Matias Kirst; Gary F. Peter; Salvador A. Gezan; C.Dana Nelson; John M. Davis

    2014-01-01

    Fusiform rust resistance can involve gene-for-gene interactions where resistance (Fr) genes in the host interact with corresponding avirulence genes in the pathogen, Cronartium quercuum f.sp. fusiforme (Cqf). Here, we identify trees with Fr genes in a loblolly pine population derived from a complex mating design challenged with two Cqf inocula (one gall and 10 gall...

  1. Censoring Data for Resistance Factor Calculations in Load and Resistance Factor Design: A Preliminary Study

    Science.gov (United States)

    James W. Evans; David W. Green

    2007-01-01

    Reliability estimates for the resistance distribution of wood product properties may be made from test data where all specimens are broken (full data sets) or by using data sets where information is obtained only from the weaker pieces in the distribution (censored data). Whereas considerable information exists on property estimation from full data sets, much less...

  2. Scrubbing system design for CO{sub 2} capture in coal-fired power plants

    Energy Technology Data Exchange (ETDEWEB)

    Heischkamp, Elizabeth

    2017-07-01

    Within the last decades a continuous tightening of environmental regulations has been observed in several countries around the world. These include restriction of anthropogenic CO{sub 2} emissions, since they are considered responsible for intensifying global warming. Coal-fired power plants represent a good possibility for capturing CO{sub 2} before it is emitted in the atmosphere, thereby contributing to combat global warming. This work focuses on reducing the CO{sub 2} emissions of such a power plant by 90 %. For this purpose a hard coal power plant is retrofitted with a chemical absorption using different solutions of piperazine promoted potassium carbonate. The resulting power plant's efficiency losses have been accounted for. A comparison of different scenarios such as the variation of operating parameters offer an insight in detecting suitable operating conditions that will allow to minimize efficiency penalties. Simulation details are provided along with a technical and an economic analysis.

  3. Scrubbing system design for CO2 capture in coal-fired power plants

    International Nuclear Information System (INIS)

    Heischkamp, Elizabeth

    2017-01-01

    Within the last decades a continuous tightening of environmental regulations has been observed in several countries around the world. These include restriction of anthropogenic CO 2 emissions, since they are considered responsible for intensifying global warming. Coal-fired power plants represent a good possibility for capturing CO 2 before it is emitted in the atmosphere, thereby contributing to combat global warming. This work focuses on reducing the CO 2 emissions of such a power plant by 90 %. For this purpose a hard coal power plant is retrofitted with a chemical absorption using different solutions of piperazine promoted potassium carbonate. The resulting power plant's efficiency losses have been accounted for. A comparison of different scenarios such as the variation of operating parameters offer an insight in detecting suitable operating conditions that will allow to minimize efficiency penalties. Simulation details are provided along with a technical and an economic analysis.

  4. Re-sensitizing drug-resistant bacteria to antibiotics by designing Antisense Therapeutics

    Science.gov (United States)

    Courtney, Colleen; Chatterjee, Anushree

    2014-03-01

    ``Super-bugs'' or ``multi-drug resistant organisms'' are a serious international health problem, with devastating consequences to patient health care. The Center for Disease Control has identified antibiotic resistance as one of the world's most pressing public health problems as a significant fraction of bacterial infections contracted are drug resistant. Typically, antibiotic resistance is encoded by ``resistance-genes'' which express proteins that carryout the resistance causing functions inside the bacterium. We present a RNA based therapeutic strategy for designing antimicrobials capable of re-sensitizing resistant bacteria to antibiotics by targeting labile regions of messenger RNAs encoding for resistance-causing proteins. We perform in silico RNA secondary structure modeling to identify labile target regions in an mRNA of interest. A synthetic biology approach is then used to administer antisense nucleic acids to our model system of ampicillin resistant Escherichia coli. Our results show a prolonged lag phase and decrease in viability of drug-resistant E. colitreated with antisense molecules. The antisense strategy can be applied to alter expression of other genes in antibiotic resistance pathways or other pathways of interest.

  5. Resisting Technological Gravity: Using Guiding Principles for Instructional Design

    Science.gov (United States)

    McDonald, Jason K.

    2010-01-01

    Instructional designers face tremendous pressure to abandon the essential characteristics of educational approaches, and settle instead for routine practices that do not preserve the level of quality those approaches originally expressed. Because this pressure can be strong enough to affect designers almost as gravity affects objects in the…

  6. Embedded data collector (EDC) phase II load and resistance factor design (LRFD) : [summary].

    Science.gov (United States)

    2015-07-01

    Piles that support bridge structures are designed for the specific site characteristics and loads : that the piles are expected to bear. In Florida, driven piles are monitored during installation : (dynamically tested) to assess resistance, com...

  7. Structural design guidelines for concrete bridge decks reinforced with corrosion-resistant reinforcing bars.

    Science.gov (United States)

    2014-10-01

    This research program develops and validates structural design guidelines and details for concrete bridge decks with : corrosion-resistant reinforcing (CRR) bars. A two-phase experimental program was conducted where a control test set consistent : wi...

  8. Resistive RAM: Simulation and Modeling for Reliable Design

    OpenAIRE

    García Redondo, Fernando

    2017-01-01

    Las tecnologías emergentes de resistencia variable o resistencia-commutativa, Resistive-Switching (RS) technologies, están consideradas como una de las alternativas más prometedoras para el futuro de aplicaciones electrónicas de almacenamiento y sistemas de computación. Características tales como su no-volatilidad, alta densidad de integración, bajo consumo, así como su compatibilidad con circuitos CMOS tradicionales, despierta el interés de fabricantes de dispositivos, diseñadores de circuit...

  9. Chapter 6: Fire damage of wood structures

    Science.gov (United States)

    B. Kukay; R.H. White; F. Woeste

    2012-01-01

    Depending on the severity, fire damage can compromise the structural integrity of wood structures such as buildings or residences. Fire damage of wood structures can incorporate several models that address (1) the type, cause, and spread of the fire, (2) the thermal gradients and fire-resistance ratings, and (3) the residual load capacity (Figure 6.1). If there is a...

  10. Designing Base and Subbase to Resist Environmental Effects on Pavements

    Science.gov (United States)

    2018-02-02

    MnDOTs current pavement thickness design procedures do not characterize the effects of subgrade soil frost susceptibility. Previous research indicates frost action is the most severe environmental factor on pavement performance. The most accepted ...

  11. Specialists' meeting on sodium fires

    Energy Technology Data Exchange (ETDEWEB)

    Kozlov, F A; Kuznetsova, R I [eds.

    1989-07-01

    The four sessions of the meeting covered the following topics: 1. general approach to fast reactor safety, standards of fire safety, maximum design basis accidents for sodium leaks and fires, status of sodium fires in different countries; 2. physical and chemical processes during combustion of sodium and its interaction with structural and technological materials and methods for structural protection; 3. methods of sodium fires extinguishing and measures for localizing aerosol combustion products, organization of fire fighting procedures, instruction and training of fire personnel; 4. elimination of the consequences of sodium fires.

  12. Specialists' meeting on sodium fires

    International Nuclear Information System (INIS)

    Kozlov, F.A.; Kuznetsova, R.I.

    1989-01-01

    The four sessions of the meeting covered the following topics: 1. general approach to fast reactor safety, standards of fire safety, maximum design basis accidents for sodium leaks and fires, status of sodium fires in different countries; 2. physical and chemical processes during combustion of sodium and its interaction with structural and technological materials and methods for structural protection; 3. methods of sodium fires extinguishing and measures for localizing aerosol combustion products, organization of fire fighting procedures, instruction and training of fire personnel; 4. elimination of the consequences of sodium fires

  13. Solving the Problem of Multiple-Criteria Building Design Decisions with respect to the Fire Safety of Occupants: An Approach Based on Probabilistic Modelling

    Directory of Open Access Journals (Sweden)

    Egidijus Rytas Vaidogas

    2015-01-01

    Full Text Available The design of buildings may include a comparison of alternative architectural and structural solutions. They can be developed at different levels of design process. The alternative design solutions are compared and ranked by applying methods of multiple-criteria decision-making (MCDM. Each design is characterised by a number of criteria used in a MCDM problem. The paper discusses how to choose MCDM criteria expressing fire safety related to alternative designs. Probability of a successful evacuation of occupants from a building fire and difference between evacuation time and time to untenable conditions are suggested as the most important criteria related to fire safety. These two criteria are treated as uncertain quantities expressed by probability distributions. Monte Carlo simulation of fire and evacuation processes is natural means for an estimation of these distributions. The presence of uncertain criteria requires applying stochastic MCDM methods for ranking alternative designs. An application of the safety-related criteria is illustrated by an example which analyses three alternative architectural floor plans prepared for a reconstruction of a medical building. A MCDM method based on stochastic simulation is used to solve the example problem.

  14. Interactions between crush conditions and fire resistance for type B(U) packages less than 500 kg

    International Nuclear Information System (INIS)

    Huebner, H.W.; Masslowski, J.P.

    1983-01-01

    In the continuation of the research work by BAM and the Commissariat a l'Energie Atomique (CEA), France, a study was made of the increased risk in regard to low-probability accidents, involving small, type B packages. An evaluation was made of the increased risk when small, type B packages are involved with a low-probability accident - one that involves both crush forces and exposure to a hydrocarbon fire. 3 references, 3 figures

  15. Application of Corrosion- and Fire-Resistant Coating Systems on Buildings 227 and 299 at Rock Island Arsenal

    Science.gov (United States)

    2009-08-01

    event of a fire. The mesh prevents cracking to the steel substrate, which would reduce the insulating properties of the char. The procedure is as...Top Coats: MPI #9, Exterior Alkyd Enamel , Gloss, MPI Gloss Level 6 (i.e., a semi-gloss) • System 2: o Primer: MPI #23, Surface Tolerant Metal...Metal Primer X X MPI Paint #9 Exterior Alkyd Enamel , Gloss X MPI Paint #94 Exterior Alkyd

  16. System design methodology of non-fossil fuel fired power plants

    International Nuclear Information System (INIS)

    Mohamed, J.A.; Guven, H.M.

    1992-01-01

    In most thermal system designs, economic and thermodynamic aspects of the design are not studied simultaneously early on in the design process. As a result, the economic ramification of thermodynamic changes to the system configuration, and vice versa, are not immediately apparent to the designer or the performance, involving both thermal and economic aspects of the plant. In this study, a rational approach is presented to formalize the design process of small power plants, typically, burning non-conventional fuel sources such as wood residues, tires, biofuels, etc. The method presented in this paper allows for handling of process information, both qualitative and quantitative, to enable the designer to change his design in an optimal manner. A two-level design structure (macro-level and micro-level), is introduced to enable the designer to adapt his design in an efficient manner to the available (or required) technology-level, type of application, economic factors, O and M requirements, etc. At the macro-level of design, economic feasibility (business) decisions are made, while at the micro-level of design, technical feasibility (engineering) decisions are made

  17. Destination, Imagination and the Fires within: Design Thinking in a Middle School Classroom

    Science.gov (United States)

    Carroll, Maureen; Goldman, Shelley; Britos, Leticia; Koh, Jaime; Royalty, Adam; Hornstein, Michael

    2010-01-01

    The purpose of the Taking Design Thinking to Schools Research Project was to extend the knowledge base that contributes to an improved understanding of the role of design thinking in K-12 classrooms. The ethnographic qualitative study focused on the implementation of an interdisciplinary design curriculum by a team of university instructors in a…

  18. The role of the fire dampers in the event of fire in a nuclear facility. Selection criteria for devices

    International Nuclear Information System (INIS)

    Savornin, J.; Laborde, J.C.

    1989-10-01

    In nuclear facilities, where unacceptable quantities of radioactive aerosols could be spread in the event of a fire, the ventilation system must be designed so that an underpressure is maintained under such circumstances. This is the reason why the extracting ventilation of the room in which the fire has broken out has generally to be kept going as long as possible. This prevents smoke and radioactive aerosols from spreading to accessways and adjacent rooms. Consequently, the various devices of the ventilation network need to have high fire resistance. Fire dampers can be applied to exhaust air to delay the heat build-up of a major fire. Specialized qualification testing is required for these dampers. The criteria we have used as a basis for specifying the required qualities of installations are defined. The tests that have been performed, or are now in progress, are described. The results obtained so far are given. Devices and arrangements are suggested

  19. The application of RANS CFD for design of SNCR technology for a pulverized coal-fired boiler

    Directory of Open Access Journals (Sweden)

    Ruszak Monika

    2017-06-01

    Full Text Available The article describes the technology of NOx emission abatement by SNCR method. The scope of research included CDF simulations as well as design and construction of the pilot plant and tests of NOx reduction by urea in the plant located in industrial pulverized-coal fired boiler. The key step of research was to determine the appropriate temperature window for the SNCR process. The proposed solution of the location of injection lances in the combustion chamber enabled to achieve over a 30% reduction of NOx. It is possible to achieve higher effectiveness of the proposed SNCR technology and meet the required emission standards via providing prior reduction of NOx to the level of 350 mg/um3 using the primary methods.

  20. Design of permanent block stopping to resist strata convergence

    Energy Technology Data Exchange (ETDEWEB)

    Ray, R.E.

    1985-11-01

    Conventional concrete block plastered with a cementitious coating is the most common material used in the construction of permanent stoppings to direct airflow in underground mines in the US. All mines experience various degrees of strata convergence depending on depth of overburden, geological conditions, and type of roof support employed. Strata convergence will cause cracks and joint openings in masonry stoppings, resulting in significant air leakage losses. Where strata convergence is severe, complete structural failure of the stopping can ultimately occur. Reconstruction of damaged or destroyed stoppings adds expensive overheads to mining operations, and even greater expenses are incurred from the additional fan horsepower required to overcome leakage losses. Ideally, a stopping should maintain high resistance to airflow while yielding to strata convergence. By properly incorporating a polyisocyanurate rigid foam material within the masonry block structure, stopping service life can be increased in mines experiencing strata convergence problems such as floor heave, roof loading, and lateral rib movement.

  1. Development of rational design technique for frame steel structure combining seismic resistance and economic performance

    International Nuclear Information System (INIS)

    Kato, Motoki; Morishita, Kunihiro; Shimono, Masaki; Chuman, Yasuharu; Okafuji, Takashi; Monaka, Toshiaki

    2015-01-01

    Anti-seismic designs have been applied to plant support steel frames for years. Today, a rational structure that further improves seismic resistance and ensures economic performance is required in response to an increase of seismic load on the assumption of predicted future massive earthquakes. For satisfying this requirement, a steel frame design method that combines a steel frame weight minimizing method, which enables economic design through simultaneous minimization of multiple steel frame materials, and a seismic response control design technology that improves seismic resistance has been established. Its application in the design of real structures has been promoted. This paper gives an overview of this design technology and presents design examples to which this design technology is applied. (author)

  2. Numerical case studies of vertical wall fire protection using water spray

    Directory of Open Access Journals (Sweden)

    L.M. Zhao

    2014-11-01

    Full Text Available Studies of vertical wall fire protection are evaluated with numerical method. Typical fire cases such as heated dry wall and upward flame spread have been validated. Results predicted by simulations are found to agree with experiment results. The combustion behavior and flame development of vertical polymethylmethacrylate slabs with different water flow rates are explored and discussed. Water spray is found to be capable of strengthening the fire resistance of combustible even under high heat flux radiation. Provided result and data are expected to provide reference for fire protection methods design and development of modern buildings.

  3. 18T resistive magnet development. Conceptual design second annual report

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, K.L.; Burgeson, J.E.; Gurol, H.; Mancuso, A.; Michels, P.H.

    1985-10-01

    This report documents the work performed on a normal conducting magnet during fiscal year 1985. Emphasis, during the study, was on refinement of the structural design and optimization of the coil current density distribution for either maximum field generation or minimum power consumption. The results have shown that one can generate a 4.4 tesla field using 6.14 megawatts or 3.1 tesla at 1.43 megawatts. The structural design has been modified to stiffen the outer turn of the conductor. The modification was confirmed to be structurally adequate by both analysis and test. 37 figs., 21 tabs.

  4. 18T resistive magnet development. Conceptual design second annual report

    International Nuclear Information System (INIS)

    Agarwal, K.L.; Burgeson, J.E.; Gurol, H.; Mancuso, A.; Michels, P.H.

    1985-10-01

    This report documents the work performed on a normal conducting magnet during fiscal year 1985. Emphasis, during the study, was on refinement of the structural design and optimization of the coil current density distribution for either maximum field generation or minimum power consumption. The results have shown that one can generate a 4.4 tesla field using 6.14 megawatts or 3.1 tesla at 1.43 megawatts. The structural design has been modified to stiffen the outer turn of the conductor. The modification was confirmed to be structurally adequate by both analysis and test. 37 figs., 21 tabs

  5. Fire safety engineering

    International Nuclear Information System (INIS)

    Smith, D.N.

    1989-01-01

    The periodic occurrence of large-scale, potentially disastrous industrial accidents involving fire in hazardous environments such as oilwell blowouts, petrochemical explosions and nuclear installations highlights the need for an integrated approach to fire safety engineering. Risk reduction 'by design' and rapid response are of equal importance in the saving of life and property in such situations. This volume of papers covers the subject thoroughly, touching on such topics as hazard analysis, safety design and testing, fire detection and control, and includes studies of fire hazard in the context of environment protection. (author)

  6. Experimental Investigation of Closed Porosity of Inorganic Solidified Foam Designed to Prevent Coal Fires

    Directory of Open Access Journals (Sweden)

    Yi Lu

    2015-01-01

    Full Text Available In order to overcome the deficiency of the existing fire control technology and control coal spontaneous combustion by sealing air leakages in coal mines, inorganic solidified foam (ISF with high closed porosity was developed. The effect of sodium dodecyl sulfate (SDS concentration on the porosity of the foams was investigated. The results showed that the optimized closed porosity of the solidified foam was 38.65 wt.% for an SDS concentration of approximately 7.4×10-3 mol/L. Based on observations of the microstructure of the pore walls after solidification, it was inferred that an equilibrium between the hydration process and the drainage process existed. Therefore, the ISF was improved using three different systems. Gelatin can increase the viscosity of the continuous phase to form a viscoelastic film around the air cells, and the SDS + gelatin system can create a mixed surfactant layer at gas/liquid interfaces. The accelerator (AC accelerates the hydration process and coagulation of the pore walls before the end of drainage. The mixed SDS + gelatin + AC systems produced an ISF with a total porosity of 79.89% and a closed porosity of 66.89%, which verified the proposed stabilization mechanism.

  7. 46 CFR 108.419 - Fire main capacity.

    Science.gov (United States)

    2010-10-01

    ... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fire Main System § 108.419 Fire main capacity. The diameter of the fire... pumps operating simultaneously. ...

  8. Fire Propagation Performance of Intumescent Fire Protective Coatings Using Eggshells as a Novel Biofiller

    Directory of Open Access Journals (Sweden)

    M. C. Yew

    2014-01-01

    Full Text Available This paper aims to synthesize and characterize an effective intumescent fire protective coating that incorporates eggshell powder as a novel biofiller. The performances of thermal stability, char formation, fire propagation, water resistance, and adhesion strength of coatings have been evaluated. A few intumescent flame-retardant coatings based on these three ecofriendly fire retardant additives ammonium polyphosphate phase II, pentaerythritol and melamine mixed together with flame-retardant fillers, and acrylic binder have been prepared and designed for steel. The fire performance of the coatings has conducted employing BS 476: Part 6-Fire propagation test. The foam structures of the intumescent coatings have been observed using field emission scanning electron microscopy. On exposure, the coated specimens’ B, C, and D had been certified to be Class 0 due to the fact that their fire propagation indexes were less than 12. Incorporation of ecofriendly eggshell, biofiller into formulation D led to excellent performance in fire stopping (index value, (I=4.3 and antioxidation of intumescent coating. The coating is also found to be quite effective in water repellency, uniform foam structure, and adhesion strength.

  9. General Concerns Life-Cycle Design of Economical Ice-Resistant Structures in the Bohai Sea

    Directory of Open Access Journals (Sweden)

    Zhang Da-yong

    2017-08-01

    Full Text Available In China, the oil and natural gas resources of Bohai Bay are mainly marginal oil fields. It is necessary to build both iceresistant and economical offshore platforms. However, there are many risks during the life cycle of offshore platforms due to the imperfect preliminary design for the Bohai Sea economical ice-resistant structures. As a result, the whole life-cycle design should be considered, including plan, design, construction, management and maintenance design. Based on the demand of existing codes and research of the basic design, structural ice-resistant performance and the reasonable management and maintenance, the life-cycle design theory is discussed. It was concluded that the life-cycle cost-effective optimum design proposed will lead to a minimum risk.

  10. Development of fire-resistant, low smoke generating, thermally stable end items for commercial aircraft and spacecraft using a basic polyimide resin

    Science.gov (United States)

    Gagliani, J.; Lee, R.; Sorathia, U. A.; Wilcoxson, A. L.

    1980-01-01

    A terpolyimide precursor was developed which can be foamed by microwave methods and yields foams possessing the best seating properties. A continuous process, based on spray drying techniques, permits production of polyimide powder precursors in large quantities. The constrained rise foaming process permits fabrication of rigid foam panels with improved mechanical properties and almost unlimited density characteristics. Polyimide foam core rigid panels were produced by this technique with woven fiberglass fabric bonded to each side of the panel in a one step microwave process. The fire resistance of polyimide foams was significantly improved by the addition of ceramic fibers to the powder precursors. Foams produced from these compositions are flexible, possess good acoustical attenuation and meet the minimum burnthrough requirements when impinged by high flux flame sources.

  11. Design of housing file box of fire academy based on RFID

    Science.gov (United States)

    Li, Huaiyi

    2018-04-01

    This paper presents a design scheme of intelligent file box based on RFID. The advantages of RFID file box and traditional file box are compared and analyzed, and the feasibility of RFID file box design is analyzed based on the actual situation of our university. After introducing the shape and structure design of the intelligent file box, the paper discusses the working process of the file box, and explains in detail the internal communication principle of the RFID file box and the realization of the control system. The application of the RFID based file box will greatly improve the efficiency of our school's archives management.

  12. Nuclear power plant design resistance to earthquakes. Pt. 3

    International Nuclear Information System (INIS)

    1990-01-01

    The rule specifies the standards to be met by the architectural design for building structures in order to ensure that they will not collapse during an earthquake. Building structures including the sub-structures covered by the rule are understood as buildings and building sections made of steel-reinforced concrete, prestressed concrete, steel and masoury (brickwork). They include i.a. crane tracks and gantries. For reactor safety containment buildings constructed of steel, steel-reinforced concrete or prestressed concrete, this rule applies for the calculation of section size. (orig./HP) [de

  13. Intrusion resistant underground structure (IRUS) : design and operations

    International Nuclear Information System (INIS)

    Lange, B.A.

    1997-01-01

    The safety case for the IRUS low-level radioactive waste disposal facility is based on the fact that IRUS will contain three specific types of wastes only. The types of these wastes are baled wastes, bituminized incinerator ash, and bituminized reverse osmosis concentrate. IRUS will be a below-ground vault consisting of an open bottom reinforced-concrete structure (approximate dimensions 30m x 20m x 8m) with a reinforced-concrete roof. This paper covers the vault design and construction and operational features. 2 tabs

  14. Improvement of fire fighting means for NPPs

    International Nuclear Information System (INIS)

    Viktorov, V.V.

    1993-01-01

    The problems dealing with testing of flame dampers for NPP ventilation systems are considered. The characteristics of the Darmatt fire-resistant material developed for protection of cable lines and equipment against fire effects are given

  15. Using resistance and resilience concepts to reduce impacts of invasive annual grasses and altered fire regimes on the sagebrush ecosystem and greater sage-grouse: A strategic multi-scale approach

    Science.gov (United States)

    Jeanne C. Chambers; David A. Pyke; Jeremy D. Maestas; Mike Pellant; Chad S. Boyd; Steven B. Campbell; Shawn Espinosa; Douglas W. Havlina; Kenneth E. Mayer; Amarina Wuenschel

    2014-01-01

    This Report provides a strategic approach for conservation of sagebrush ecosystems and Greater Sage- Grouse (sage-grouse) that focuses specifically on habitat threats caused by invasive annual grasses and altered fire regimes. It uses information on factors that influence (1) sagebrush ecosystem resilience to disturbance and resistance to invasive annual grasses and (2...

  16. Design and construction of a resistive energy dump device for bipolar superconducting magnet systems

    Energy Technology Data Exchange (ETDEWEB)

    Mohan, M. J.

    1977-05-01

    When superconducting magnets quench, the resistance of the conductor material rises rapidly to its normal value. This increase in resistance can result in catastrophic heating in the magnet unless stored field energy is quickly removed from the system. Phase inversion is the normal mode of energy removal. SCR's in the power supply are phased back, the output of the supply is inverted, and magnetic field energy is directed back into the utility grid. Under certain conditions, however, the power supply may fail to invert properly, and an alternate energy removal scheme must protect the superconducting magnet system. Composed of an isolation switch, a semiconductor switching module, and a dump resistor, the resistive dump device provides a viable protection scheme. Operationally, several conditions are capable of activating the isolation switch and triggering the bipolar SCR switching module. Manual dump commands, for instance, permit the operator to dump field energy in the event of observed abnormalities. A special voltage tap quench detector senses the aforementioned abnormal power supply output inversion and also fires the dump circuit. Regardless of the nature of the trigger input, however, activation of the energy dump device diverts coil current through the dump resistor. I/sup 2/R losses over time then safely dissipate stored magnetic field energy.

  17. Reliability-based load and resistance factor design for piping: an exploratory case study

    International Nuclear Information System (INIS)

    Gupta, Abhinav; Choi, Byounghoan

    2003-01-01

    This paper presents an exploratory case study on the application of Load and Resistance Factor Design (LRFD) approach to the Section III of ASME Boiler and Pressure Vessel code for piping design. The failure criterion for defining the performance function is considered as plastic instability. Presently used design equation is calibrated by evaluating the minimum reliability levels associated with it. If the target reliability in the LRFD approach is same as that evaluated for the presently used design equation, it is shown that the total safety factors for the two design equations are identical. It is observed that the load and resistance factors are not dependent upon the diameter to thickness ratio. A sensitivity analysis is also conducted to study the variations in the load and resistance factors due to changes in (a) coefficients of variation for pressure, moment, and ultimate stress, (b) ratio of mean design pressure to mean design moment, (c) distribution types used for characterizing the random variables, and (d) statistical correlation between random variables. It is observed that characterization of random variables by log-normal distribution is reasonable. Consideration of statistical correlation between the ultimate stress and section modulus gives higher values of the load factor for pressure but lower value for the moment than the corresponding values obtained by considering the variables to be uncorrelated. Since the effect of statistical correlation on the load and resistance factors is relatively insignificant for target reliability values of practical interest, the effect of correlated variables may be neglected

  18. Lightweight, fire-retardant, crashworthy aircraft seat cushioning

    Science.gov (United States)

    Haslim, Leonard A.; Mcdonough, Paul T.

    1991-01-01

    A two page discussion of non-aerospace seating applications and the design of NASA's safety seat cushioning (SSC) is presented. The SSC was designed for both safety and comfort in order to replace polyurethane cushioning which is flammable and produces lethal fumes upon combustion. The SSC is composed of advanced fabric reinforced composites and is lightweight, fire-retardent, and crashworthy. The seat design consists of central elliptical tubular spring supports made of fire-resistant and fatigue-durable composites surrounded by a fire-blocking sheath. The cushioning is made crashworthy by incorporating energy-absorbing, viscoelastic layers between the nested, elliptical-hoop springs. The design is intended to provide comfortable seating that meets aircraft-loading requirements without using the conventional polyurethane materials. The designs of an aircraft seat and structural components of the SSC are also presented.

  19. Optimized design of a low-resistance electrical conductor for the multimegahertz range

    Science.gov (United States)

    Kurs, André; Kesler, Morris; Johnson, Steven G.

    2011-04-01

    We propose a design for a conductive wire composed of several mutually insulated coaxial conducting shells. With the help of numerical optimization, it is possible to obtain electrical resistances significantly lower than those of a heavy-gauge copper wire or litz wire in the 2-20 MHz range. Moreover, much of the reduction in resistance can be achieved for just a few shells; in contrast, litz wire would need to contain ˜104 strands to perform comparably in this frequency range.

  20. Fire protection and fire fighting in nuclear installations

    International Nuclear Information System (INIS)

    1989-01-01

    Fires are a threat to all technical installations. While fire protection has long been a well established conventional discipline, its application to nuclear facilities requires special considerations. Nevertheless, for a long time fire engineering has been somewhat neglected in the design and operation of nuclear installations. In the nuclear industry, the Browns Ferry fire in 1975 brought about an essential change in the attention paid to fire problems. Designers and plant operators, as well as insurance companies and regulators, increased their efforts to develop concepts and methods for reducing fire risks, not only to protect the capital investment in nuclear plants but also to consider the potential secondary effects which could lead to nuclear accidents. Although the number of fires in nuclear installations is still relatively large, their overall importance to the safety of nuclear power plants was not considered to be very high. Only more recently have probabilistic analyses changed this picture. The results may well have to be taken into account more carefully. Various aspects of fire fighting and fire protection were discussed during the Symposium, the first of its kind to be organized by the IAEA. It was convened in co-operation with several organizations working in the nuclear or fire protection fields. The intention was to gather experts from nuclear engineering areas and the conventional fire protection field at one meeting with a view to enhancing the exchange of information and experience and to presenting current knowledge on the various disciplines involved. The presentations at the meeting were subdivided into eight sessions: standards and licensing (6 papers); national fire safety practices (7 papers); fire safety by design (11 papers); fire fighting (2 papers); computer fire modeling (7 papers); fire safety in fuel center facilities (7 papers); fire testing of materials (3 papers); fire risk assessment (5 papers). A separate abstract was

  1. Design of a horizontal penetrometer for measuring on-the-go soil resistance.

    Science.gov (United States)

    Topakci, Mehmet; Unal, Ilker; Canakci, Murad; Celik, Huseyin Kursat; Karayel, Davut

    2010-01-01

    Soil compaction is one of the main negative factors that limits plant growth and crop yield. Therefore, it is important to determine the soil resistance level and map it for the field to find solutions for the negative effects of the compaction. Nowadays, high powered communication technology and computers help us on this issue within the approach of precision agriculture applications. This study is focused on the design of a penetrometer, which can make instantaneous soil resistance measurements in the soil horizontally and data acquisition software based on the GPS (Global Positioning System). The penetrometer was designed using commercial 3D parametric solid modelling design software. The data acquisition software was developed in Microsoft Visual Basic.NET programming language. After the design of the system, manufacturing and assembly of the system was completed and then a field experiment was carried out. According to the data from GPS and penetration resistance values which are collected in Microsoft SQL Server database, a Kriging method by ArcGIS was used and soil resistance was mapped in the field for a soil depth of 40 cm. During operation, no faults, either in mechanical and software parts, were seen. As a result, soil resistance values of 0.2 MPa and 3 MPa were obtained as minimum and maximum values, respectively. In conclusion, the experimental results showed that the designed system works quite well in the field and the horizontal penetrometer is a practical tool for providing on-line soil resistance measurements. This study contributes to further research for the development of on-line soil resistance measurements and mapping within the precision agriculture applications.

  2. Design of a Horizontal Penetrometer for Measuring On‑the‑Go Soil Resistance

    Directory of Open Access Journals (Sweden)

    Davut Karayel

    2010-10-01

    Full Text Available Soil compaction is one of the main negative factors that limits plant growth and crop yield. Therefore, it is important to determine the soil resistance level and map it for the field to find solutions for the negative effects of the compaction. Nowadays, high powered communication technology and computers help us on this issue within the approach of precision agriculture applications. This study is focused on the design of a penetrometer, which can make instantaneous soil resistance measurements in the soil horizontally and data acquisition software based on the GPS (Global Positioning System. The penetrometer was designed using commercial 3D parametric solid modelling design software. The data acquisition software was developed in Microsoft Visual Basic.NET programming language. After the design of the system, manufacturing and assembly of the system was completed and then a field experiment was carried out. According to the data from GPS and penetration resistance values which are collected in Microsoft SQL Server database, a Kriging method by ArcGIS was used and soil resistance was mapped in the field for a soil depth of 40 cm. During operation, no faults, either in mechanical and software parts, were seen. As a result, soil resistance values of 0.2 MPa and 3 MPa were obtained as minimum and maximum values, respectively. In conclusion, the experimental results showed that the designed system works quite well in the field and the horizontal penetrometer is a practical tool for providing on‑line soil resistance measurements. This study contributes to further research for the development of on-line soil resistance measurements and mapping within the precision agriculture applications.

  3. Generation of advanced fire blight-resistant apple (Malus × domestica) selections of the fifth generation within 7 years of applying the early flowering approach.

    Science.gov (United States)

    Schlathölter, Ina; Jänsch, Melanie; Flachowsky, Henryk; Broggini, Giovanni Antonio Lodovico; Hanke, Magda-Viola; Patocchi, Andrea

    2018-03-14

    The approach presented here can be applied to reduce the time needed to introduce traits from wild apples into null segregant advanced selections by one-fourth. Interesting traits like resistances to pathogens are often found within the wild apple gene pool. However, the long juvenile phase of apple seedlings hampers the rapid introduction of these traits into new cultivars. The rapid crop cycle breeding approach used in this paper is based on the overexpression of the birch (Betula pendula) MADS4 transcription factor in apple. Using the early flowering line T1190 and 'Evereste' as source of the fire blight resistance (Fb_E locus), we successfully established 18 advanced selections of the fifth generation in the greenhouse within 7 years. Fifteen individuals showed the habitus expected of a regular apple seedling, while three showed very short internodes. The null segregants possessing a regular habitus maintained the high level of fire blight resistance typical for 'Evereste'. Using SSR markers, we estimated the percentage of genetic drag from 'Evereste' still associated with Fb_E on linkage group 12 (LG12). Eight out of the 18 selections had only 4% of 'Evereste' genome left. Since genotypes carrying the apple scab resistance gene Rvi6 and the fire blight resistance QTL Fb_F7 were used as parents in the course of the experiments, these resistances were also identified in some of the null segregants. One seedling is particularly interesting as, beside Fb_E, it also carries Fb_F7 heterozygously and Rvi6 homozygously. If null segregants obtained using this method will be considered as not genetically modified in Europe, as is already the case in the USA, this genotype could be a very promising parent for breeding new fire blight and scab-resistant apple cultivars in European apple breeding programs.

  4. Material design of negative-tone polyphenol resist for EUV and EB lithography

    Science.gov (United States)

    Kojima, Kyoko; Mori, Shigeki; Shiono, Daiju; Hada, Hideo; Onodera, Junichi

    2007-03-01

    In order to enable design of a negative-tone polyphenol resist using polarity-change reaction, five resist compounds (3M6C-MBSA-BLs) with different number of functional group of γ-hydroxycarboxyl acid were prepared and evaluated by EB lithography. The resist using mono-protected compound (3M6C-MBSA-BL1a) showed 40-nm hp resolution at an improved dose of 52 μC/cm2 probably due to removal of a non-protected polyphenol while the sensitivity of the resist using a compound of protected ratio of 1.1 on average with distribution of different protected ratio was 72 μC/cm2. For evaluation of the di-protected compound based resist, a di-protected polyphenol was synthesized by a newly developed synthetic route of 3-steps reaction, which is well-suited for mass production. The resist using di-protected compound (3M6C-MBSA-BL2b) also showed 40-nm hp resolution at a dose of 40 μC/cm2, which was faster than that of mono-protected resist. Fundamental EUV lithographic evaluation of the resist using 3M6C-MBSA-BL2b by an EUV open frame exposure tool (EUVES-7000) gave its estimated optimum sensitivity of 7 mJ/cm2 and a proof of fine development behavior without any swelling.

  5. A quantitative performance assessment of improved cooking stoves and traditional three-stone-fire stoves using a two-pot test design in Chamwino, Dodoma, Tanzania

    Science.gov (United States)

    Hafner, J.; Uckert, G.; Graef, F.; Hoffmann, H.; Kimaro, A. A.; Sererya, O.; Sieber, S.

    2018-02-01

    In Tanzania, a majority of rural residents cook using firewood-based three-stone-fire stoves. In this study, quantitative performance differences between technologically advanced improved cooking stoves and three-stone-fire stoves are analysed. We test the performance of improved cooking stoves and three-stone-fire stoves using local cooks, foods, and fuels, in the semi-arid region of Dodoma in Tanzania. We used the cooking protocol of the Controlled Cooking Test following a two-pot test design. The findings of the study suggest that improved cooking stoves use less firewood and less time than three-stone-fire stoves to conduct a predefined cooking task. In total, 40 households were assessed and ask to complete two different cooking tasks: (1) a fast cooking meal (rice and vegetables) and (2) a slow cooking meal (beans and rice). For cooking task 1, the results show a significant reduction in firewood consumption of 37.1% by improved cooking stoves compared to traditional three-stone-fire stoves; for cooking task 2 a reduction of 15.6% is found. In addition, it was found that the time needed to conduct cooking tasks 1 and 2 was significantly reduced by 26.8% and 22.8% respectively, when improved cooking stoves were used instead of three-stone-fire-stoves. We observed that the villagers altered the initial improved cooking stove design, resulting in the so-called modified improved cooking stove. In an additional Controlled Cooking Test, we conducted cooking task 3: a very fast cooking meal (maize flour and vegetables) within 32 households. Significant changes between the initial and modified improved cooking stoves regarding firewood and time consumption were not detected. However, analyses show that both firewood and time consumption during cooking was reduced when large amounts (for 6-7 household members) of food were prepared instead of small amounts (for 2-3 household members).

  6. Design, construction and test run of a two-tonne capacity solar rice dryer with rice-husk-fired auxiliary heater

    International Nuclear Information System (INIS)

    Iloeje, O.C.; Ekechukwu, O.V.; Ezeike, G.O.I.

    1993-09-01

    The design and construction details of a two-tonne per batch capacity natural-circulation solar rice dryer and the highlights of the design of its rice-husk-fired auxiliary heating system which is still under construction are presented. The dryer measures approximately 17.7m long by 9.8m wide by 6m high. Preliminary results of a test run on the solar dryer section only is reported. (author). 5 refs, 3 figs

  7. A comparison between prescriptive- and performance-based approaches in fire safety design of structures

    DEFF Research Database (Denmark)

    Budny, Iwona; Giuliani, Luisa

    2010-01-01

    methodology of the performance-based fire design approach is considered, with the avail of computer-aided simulations of the main frame of the car-park. Nonlinear analyses, with respect to thermally induced effects and emphasis laid to the collapse modality, are carried out on a frame of the considered...

  8. Structural Glass Systems under Fire: Overview of Design Issues, Experimental Research, and Developments

    OpenAIRE

    Bedon, Chiara

    2017-01-01

    Architectural design concepts incorporating glass beams, panels, or generally load-carrying elements and stiffeners for buildings, claddings, windows, and partitions are largely considered in modern high-rise constructions. A multitude of aspects, including motivations related to transparency, aesthetics, illumination, and energy conservation, progressively increased the use and interest for such a still rather innovative constructional material. However, compared to other traditional materia...

  9. High-throughput design of low-activation, high-strength creep-resistant steels for nuclear-reactor applications

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Qi; Zwaag, Sybrand van der [Novel Aerospace Materials Group, Faculty of Aerospace Engineering, Delft University of Technology, Kluyverweg 1, 2629 HS, Delft (Netherlands); Xu, Wei, E-mail: xuwei@ral.neu.edu.cn [State Key Laboratory of Rolling and Automation, Northeastern University, 110819, Shenyang (China); Novel Aerospace Materials Group, Faculty of Aerospace Engineering, Delft University of Technology, Kluyverweg 1, 2629 HS, Delft (Netherlands)

    2016-02-15

    Reduced-activation ferritic/martensitic steels are prime candidate materials for structural applications in nuclear power reactors. However, their creep strength is much lower than that of creep-resistant steel developed for conventional fossil-fired power plants as alloying elements with a high neutron activation cannot be used. To improve the creep strength and to maintain a low activation, a high-throughput computational alloy design model coupling thermodynamics, precipitate-coarsening kinetics and an optimization genetic algorithm, is developed. Twelve relevant alloying elements with either low or high activation are considered simultaneously. The activity levels at 0–10 year after the end of irradiation are taken as optimization parameter. The creep-strength values (after exposure for 10 years at 650 °C) are estimated on the basis of the solid-solution strengthening and the precipitation hardening (taking into account precipitate coarsening). Potential alloy compositions leading to a high austenite fraction or a high percentage of undesirable second phase particles are rejected automatically in the optimization cycle. The newly identified alloys have a much higher precipitation hardening and solid-solution strengthening at the same activity level as existing reduced-activation ferritic/martensitic steels.

  10. FIRE PROTECTION SYSTEMS AND TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    Aristov Denis Ivanovich

    2016-03-01

    Full Text Available The All-Russian Congress “Fire Stop Moscow” was de-voted to the analysis of the four segments of the industry of fire protection systems and technologies: the design of fire protec-tion systems, the latest developments and technologies of active and passive fire protection of buildings, the state and the devel-opment of the legal framework, the practice of fire protection of buildings and structures. The forum brought together the repre-sentatives of the industry of fire protection systems, scientists, leading experts, specialists in fire protection and representatives of construction companies from different regions of Russia. In parallel with the Congress Industrial Exhibition of fire protection systems, materials and technology was held, where manufacturers presented their products. The urgency of the “Fire Stop Moscow” Congress in 2015 organized by the Congress Bureau ODF Events lies primarily in the fact that it considered the full range of issues related to the fire protection of building and construction projects; studied the state of the regulatory framework for fire safety and efficiency of public services, research centers, private companies and busi-nesses in the area of fire safety. The main practical significance of the event which was widely covered in the media space, was the opportunity to share the views and information between management, science, and practice of business on implementing fire protection systems in the conditions of modern economic relations and market realities. : congress, fire protection, systems, technologies, fire protection systems, exhibition

  11. 36 CFR 331.15 - Fires.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Fires. 331.15 Section 331.15... INDIANA § 331.15 Fires. Open fires are prohibited unless confined to fireplaces, grills, or other facilities designed for this purpose as designated by the District Engineer. Fires shall not be left...

  12. Fire exposed aluminium structures

    NARCIS (Netherlands)

    Maljaars, J.; Fellinger, J.E.J.; Soetens, F.

    2005-01-01

    Material properties and mechanical response models for fire design of steel structures are based on extensive research and experience. Contrarily, the behaviour of aluminium load bearing structures exposed to fire is relatively unexplored. This article gives an overview of physical and mechanical

  13. Proposed Modifications to Engineering Design Guidelines Related to Resistivity Measurements and Spacecraft Charging

    Science.gov (United States)

    Dennison, J. R.; Swaminathan, Prasanna; Jost, Randy; Brunson, Jerilyn; Green, Nelson; Frederickson, A. Robb

    2005-01-01

    A key parameter in modeling differential spacecraft charging is the resistivity of insulating materials. This determines how charge will accumulate and redistribute across the spacecraft, as well as the time scale for charge transport and dissipation. Existing spacecraft charging guidelines recommend use of tests and imported resistivity data from handbooks that are based principally upon ASTM methods that are more applicable to classical ground conditions and designed for problems associated with power loss through the dielectric, than for how long charge can be stored on an insulator. These data have been found to underestimate charging effects by one to four orders of magnitude for spacecraft charging applications. A review is presented of methods to measure the resistive of highly insulating materials, including the electrometer-resistance method, the electrometer-constant voltage method, the voltage rate-of-change method and the charge storage method. This is based on joint experimental studies conducted at NASA Jet Propulsion Laboratory and Utah State University to investigate the charge storage method and its relation to spacecraft charging. The different methods are found to be appropriate for different resistivity ranges and for different charging circumstances. A simple physics-based model of these methods allows separation of the polarization current and dark current components from long duration measurements of resistivity over day- to month-long time scales. Model parameters are directly related to the magnitude of charge transfer and storage and the rate of charge transport. The model largely explains the observed differences in resistivity found using the different methods and provides a framework for recommendations for the appropriate test method for spacecraft materials with different resistivities and applications. The proposed changes to the existing engineering guidelines are intended to provide design engineers more appropriate methods for

  14. Special requirements for the fluid mechanical design of hard coal-fired SCR retrofit units

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    The system design of high-dust SCR units for retrofits is a challenge that is to be mastered in order to meet the fluid mechanical requirements. Retrofitting power plants with NOx control technologies is a cost-intensive adventure that many utilities are undertaking. Except for a few recent new boiler installations, SCR installations must be considered as retrofit projects. In most cases the limitation of space on site entails unfavorable conditions that do not allow appropriate upstream conditions for SCR catalysts. To comply with the requirements of high performance DeNOx systems and to lower the investment costs for retrofit units, several technical solutions and concepts for the reactor layout, for NOx and dust distribution, for flow stabilization in diffusers, and advanced ammonia injection systems are explained in this paper. Balcke-Duerr offers customer-tailored solutions for flow optimization, which are evaluated by model studies. Physical flow and dust model tests in an appropriate scale provide flexibility to test various engineering concepts. The experience of Balcke-Duerr is based on continuous research and development activities over the last 25 years and more than 350 executed projects for gas flow optimization applications. The success of these installations is a direct result of the key decisions based on the improved fluid mechanical design and proper system integration. This paper also identifies the sensible design particularities and solutions that have two be considered in the fluid mechanical design of high-dust SCR retrofit units. This article demonstrates that the layout of SCR units must be carefully reviewed in order to meet the performance requirements and to avoid problems, i.e. wear, catalyst plugging and ammonia slip. 9 refs., 18 figs.

  15. Design of a Percussion and Electric Primer Gun Firing Power Supply

    Science.gov (United States)

    2014-07-01

    solenoid failure. As new instrumentation techniques such as high-speed video and laser interferometry have been introduced into our gun testing...to drive a solenoid into a percussion primer or ignite the M52A3B1 electric primer. To reduce power requirements, it uses charged capacitor banks to...drive the solenoid or ignite the primer. This report details the design and construction of the power supplies. 15. SUBJECT TERMS power supply

  16. Quantitative comparison of fire danger index performance using fire activity

    CSIR Research Space (South Africa)

    Steenkamp, KC

    2012-07-01

    Full Text Available parameters such as flame length or rate of spread can be physically measured or modeled. Fire danger indices are not designed to describe the characteristics of a fire but rather the potential of a fire taking place in an area of interest [5]. Several...

  17. The French fire protection concept. Vulnerability analysis

    International Nuclear Information System (INIS)

    Kaercher, M.

    1998-01-01

    The French fire protection concept is based on a principle of three levels of defence in depth: fire prevention, fire containing and fire controlling. Fire prevention is based on arrangements which prevent the fire from starting or which make difficult for the fire to start. Fire containing is based on design measures so that the fire will have no impact on the safety of the installation. For fire controlling, equipment nad personnel are on duty in order to detect, to fight and to gain control over the fire as early as possible. The French fire protection concept gives priority to fire containing based on passive structural measures. All buildings containing safety equipment are divided into fire compartments (or fire areas) and fire cells (or fire zones). Basically, a compartment houses safety equipment belonging to one division (or train) so that the other division is always available to reach the plant safe shut down or to mitigate an accident. Because there is a large number of fire compartments and fire cells, deviations from the general principle can be observed. To this reason the RCC-I (Design and Construction Rules applicable for fire protection) requires to implement an assessment of the principle of division. This assessment is called vulnerability analysis. The vulnerability analysis is usually performed at the end of the project, before erection. It is also possible to perform a vulnerability analysis in an operating nuclear power plant in the scope of a fire safety upgrading programme. In the vulnerability analysis, the functional failure of all the equipment (except for those protected by a qualified fire barrier, designed or able to withstand the fire consequences) within the fire compartment or cell, where the fire breaks out, is postulated. The potential consequences for the plant safety are analysed

  18. Fire intensity impacts on post-fire temperate coniferous forest net primary productivity

    Science.gov (United States)

    Sparks, Aaron M.; Kolden, Crystal A.; Smith, Alistair M. S.; Boschetti, Luigi; Johnson, Daniel M.; Cochrane, Mark A.

    2018-02-01

    Fire is a dynamic ecological process in forests and impacts the carbon (C) cycle through direct combustion emissions, tree mortality, and by impairing the ability of surviving trees to sequester carbon. While studies on young trees have demonstrated that fire intensity is a determinant of post-fire net primary productivity, wildland fires on landscape to regional scales have largely been assumed to either cause tree mortality, or conversely, cause no physiological impact, ignoring the impacted but surviving trees. Our objective was to understand how fire intensity affects post-fire net primary productivity in conifer-dominated forested ecosystems on the spatial scale of large wildland fires. We examined the relationships between fire radiative power (FRP), its temporal integral (fire radiative energy - FRE), and net primary productivity (NPP) using 16 years of data from the MOderate Resolution Imaging Spectrometer (MODIS) for 15 large fires in western United States coniferous forests. The greatest NPP post-fire loss occurred 1 year post-fire and ranged from -67 to -312 g C m-2 yr-1 (-13 to -54 %) across all fires. Forests dominated by fire-resistant species (species that typically survive low-intensity fires) experienced the lowest relative NPP reductions compared to forests with less resistant species. Post-fire NPP in forests that were dominated by fire-susceptible species were not as sensitive to FRP or FRE, indicating that NPP in these forests may be reduced to similar levels regardless of fire intensity. Conversely, post-fire NPP in forests dominated by fire-resistant and mixed species decreased with increasing FRP or FRE. In some cases, this dose-response relationship persisted for more than a decade post-fire, highlighting a legacy effect of fire intensity on post-fire C dynamics in these forests.

  19. Basic design of radiation-resistant LVDTs: Linear Variable Differential Transformer

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, J. M.; Park, S. J.; Kang, Y. H. (and others)

    2008-02-15

    A LVDT(Linear Variable Differential Transformer) for measuring the pressure level was used to measure the pressure of a nuclear fuel rod during the neutron irradiation test in a research reactor. A LVDT for measuring the elongation was also used to measure the elongation of nuclear fuels, and the creep and fatigue of materials during a neutron irradiation test in a research reactor. In this report, the basic design of two radiation-resistant LVDTs for measuring the pressure level and elongation are described. These LVDTs are used a under radiation environment such as a research reactor. In the basic design step, we analyzed the domestic and foreign technical status for radiation-resistant LVDTs, made part and assembly drawings and established simple procedures for their assembling. Only a few companies in the world can produce radiation-resistant LVDTs. Not only these are extremely expensive, but the prices are continuously rising. Also, it takes a long time to procure a LVDT, as it can only be bought about by an order-production. The localization of radiation-resistant LVDTs is necessary in order to provide them quickly and at a low cost. These radiation-resistant LVDTs will be used at neutron irradiation devices such as instrumented fuel capsules, special purpose capsules and a fuel test loop in research reactors. We expect that the use of neutron irradiation tests will be revitalized by the localization of radiation-resistant LVDTs.

  20. Deterioration of mechanical properties of high strength structural steel S460N under transient state fire condition

    International Nuclear Information System (INIS)

    Qiang, Xuhong; Bijlaard, Frans S.K.; Kolstein, Henk

    2012-01-01

    Highlights: ► Mechanical properties of S460N under transient state fire condition are obtained. ► Elevated-temperature mechanical properties of steels are dependent on steel grades. ► No design standard is applicable to HSS S460N under transient state fire condition. ► Specific statements on various HSS in fire should be proposed in design standards. ► Research results offer accurate material property for structural design engineers. -- Abstract: 911 World Trade Centre Tragedy put fire safety of constructional steel structures into question. Since then, more and more research attention has been paid to the elevated-temperature mechanical properties of structural steels, which is a critical basis of evaluating the fire performance of steel structures. In the literature the available mechanical properties of structural steels under fire conditions were mainly obtained from steady state test method, as steady state test method is easier to perform than transient state test method and offers stress–strain curves directly. However, the transient state fire condition is considered to be more realistic to represent the real condition when constructions are exposed to fire. In order to reveal the deterioration of mechanical properties of the commonly used high strength structural steel S460N under transient state fire condition, tensile tests were conducted under various constant stress levels up to 800 MPa. The reduction factors of elastic modulus, yield and ultimate strengths of S460N under transient state fire condition were obtained and compared with current leading design standards and available literature. The application of such accurate elevated-temperature mechanical properties reduction factors of S460N can ensure a safe fire-resistance design and evaluation of steel structures with high strength steel S460N under transient state fire condition. This experimental study also supports other relative research on fire performance of steel structures with

  1. System Design and Implementation of Intelligent Fire Engine Path Planning based on SAT Algorithm

    Institute of Scientific and Technical Information of China (English)

    CAI Li-sha[1; ZENG Wei-peng[1; HAN Bao-ru[1

    2016-01-01

    In this paper, in order to make intelligent fi re car complete autonomy path planning in simulation map. Proposed system design of intelligent fi re car path planning based on SAT. The system includes a planning module, a communication module, a control module. Control module via the communication module upload the initial state and the goal state to planning module. Planning module solve this planning solution,and then download planning solution to control module, control the movement of the car fi re. Experiments show this the system is tracking short time, higher planning effi ciency.

  2. Gas fired boilers: Perspective for near future fuel composition and impact on burner design process

    Science.gov (United States)

    Schiro, Fabio; Stoppato, Anna; Benato, Alberto

    2017-11-01

    The advancements on gas boiler technology run in parallel with the growth of renewable energy production. The renewable production will impact on the fuel gas quality, since the gas grid will face an increasing injection of alternative fuels (biogas, biomethane, hydrogen). Biogas allows producing energy with a lower CO2 impact; hydrogen production by electrolysis can mitigate the issues related to the mismatch between energy production by renewable and energy request. These technologies will contribute to achieve the renewable production targets, but the impact on whole fuel gas production-to-consumption chain must be evaluated. In the first part of this study, the Authors present the future scenario of the grid gas composition and the implications on gas fed appliances. Given that the widely used premixed burners are currently designed mainly by trial and error, a broader fuel gas quality range means an additional hitch on this design process. A better understanding and structuring of this process is helpful for future appliance-oriented developments. The Authors present an experimental activity on a premixed condensing boiler setup. A test protocol highlighting the burners' flexibility in terms of mixture composition is adopted and the system fuel flexibility is characterized around multiple reference conditions.

  3. Materials development for alternative rotor designs for improved fossil-fired power plants

    International Nuclear Information System (INIS)

    Scarlin, R.B.; Bertilsson, J.E.; Ernst, P.; Uggowitzer, P.J.; Speidel, M.O.

    1987-01-01

    At present developments are underway aimed at an improvement of the operating efficiency of steam turbines by an increase in the operating temperature and pressure. As a result certain critical components such as the high-pressure and intermediate-pressure rotors will be subject to higher levels of creep loading. In order to avoid the use of expensive austenitic materials with their inferior thermal fatigue properties, improved ferritic steels with 9-12% Chromium are required. The present paper considers development work on 9-12% Cr steels being performed worldwide. In particular European activities focused on boron-containing steels are highlighted. Steels with up to 100 ppm boron, now under long-term creep rupture testing, will exceed the design goal of a 10/sup 5/ hour creep rupture strength of 100 MPa at 600 0 C (-- 1100 0 F). The optimization of the steels included not only alloy composition but also austenitizing and tempering heat treatment. Weldability tests using the tungsten inert gas technique have shown positive results. Long-term testing to validate this design approach is underway

  4. Gas fired boilers: Perspective for near future fuel composition and impact on burner design process

    Directory of Open Access Journals (Sweden)

    Schiro Fabio

    2017-01-01

    Full Text Available The advancements on gas boiler technology run in parallel with the growth of renewable energy production. The renewable production will impact on the fuel gas quality, since the gas grid will face an increasing injection of alternative fuels (biogas, biomethane, hydrogen. Biogas allows producing energy with a lower CO2 impact; hydrogen production by electrolysis can mitigate the issues related to the mismatch between energy production by renewable and energy request. These technologies will contribute to achieve the renewable production targets, but the impact on whole fuel gas production-to-consumption chain must be evaluated. In the first part of this study, the Authors present the future scenario of the grid gas composition and the implications on gas fed appliances. Given that the widely used premixed burners are currently designed mainly by trial and error, a broader fuel gas quality range means an additional hitch on this design process. A better understanding and structuring of this process is helpful for future appliance-oriented developments. The Authors present an experimental activity on a premixed condensing boiler setup. A test protocol highlighting the burners' flexibility in terms of mixture composition is adopted and the system fuel flexibility is characterized around multiple reference conditions.

  5. Analysis of the Earthquake-Resistant Design Approach for Buildings in Mexico

    Directory of Open Access Journals (Sweden)

    Carrillo Julián

    2014-01-01

    Full Text Available The development of new codes for earthquake-resistant structures has made possible to guarantee a better performance of buildings, when they are subjected to seismic actions. Therefore, it is convenient that current codes for design of building become conceptually transparent when defining the strength modification factors and assessing maximum lateral displacements, so that the design process can be clearly understood by structural engineers. The aim of this study is to analyze the transparency of earthquake-resistant design approach for buildings in Mexico by means of a critical review of the factors for strength modification and displacement amplification. The approach of building design codes in US is also analyzed. It is concluded that earthquake-resistant design in Mexico have evolved in refinement and complexity. It is also demonstrated that the procedure prescribed by such design codes allows the assessment of the design strengths and displacements in a more rational way, in accordance not only with the present stage of knowledge but also with the contemporary tendencies in building codes. In contrast, the procedures used in US codes may not provide a clear view for seismic response assessment of buildings.

  6. Evaluation of earthquake resistance design for underground structures of nuclear power plant, (1)

    International Nuclear Information System (INIS)

    Tohma, Junichi; Kokusho, Kenji; Iwatate, Takahiro; Ohtomo, Keizo

    1986-01-01

    As to earthquake resistant design of underground civil engineering structures related with emergency cooling water system of nuclear power plant, it is required these structures must maintain the function of great important their own facilities during earthquakes, especially for design earthquake motion. In this study, shaft pipline, pit and duct for cooling sea water facilities were chosen as typical underground structures, and the authors deal with the seismic design method for calculation of the principal sectional force in these structures generated by design earthquake motion. Especially, comparative investigations concerned with response displacement method versus dynamic analysis methods (lumped mass analysis and finite element analysis) are discussed. (author)

  7. Seismic resistance design of nuclear power plant building structures in Japan

    International Nuclear Information System (INIS)

    Kitano, Takehito

    1997-01-01

    Japan is one of the countries where earthquakes occur most frequently in the world and has incurred a lot of disasters in the past. Therefore, the seismic resistance design of a nuclear power plant plays a very important role in Japan. This report describes the general method of seismic resistance design of a nuclear power plant giving examples of PWR and BWR type reactor buildings in Japan. Nuclear facilities are classified into three seismic classes and is designed according to the corresponding seismic class in Japan. Concerning reactor buildings, the short-term allowable stress design is applied for the S1 seismic load and it is confirmed that the structures have a safety margin against the S2 seismic load. (J.P.N.)

  8. Seismic resistance design of nuclear power plant building structures in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Kitano, Takehito [Kansai Electric Power Co., Inc., Osaka (Japan)

    1997-03-01

    Japan is one of the countries where earthquakes occur most frequently in the world and has incurred a lot of disasters in the past. Therefore, the seismic resistance design of a nuclear power plant plays a very important role in Japan. This report describes the general method of seismic resistance design of a nuclear power plant giving examples of PWR and BWR type reactor buildings in Japan. Nuclear facilities are classified into three seismic classes and is designed according to the corresponding seismic class in Japan. Concerning reactor buildings, the short-term allowable stress design is applied for the S1 seismic load and it is confirmed that the structures have a safety margin against the S2 seismic load. (J.P.N.)

  9. Polyfire project- an example of an industrial research project promoting safe industrial production of fire-resistant nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Vaquero, C; Lopez de Ipina, J; Galarza, N [TECNALIA, Leonardo Da Vinci No 11, 01510 Minano (Alava) (Spain); Hargreaves, B; Weager, B [NetComposites Ltd, 4A Broom Business Park, Chesterfield S41 9QG (United Kingdom); Breen, C, E-mail: celinav@leia.es [Materials and Engineering Research Institute, Sheffield Hallam University, Sheffield S1 1WB (United Kingdom)

    2011-07-06

    New developments based on nanotechnology have to guarantee safe products and processes to be accepted by society. The Polyfire project will develop and scale-up techniques for processing halogen-free, fire-retardant nanocomposite materials and coatings based on unsaturated polyester resins and organoclays. The project includes a work package that will assess the Health and Environmental impacts derived from the manipulation of nanoparticles. This work package includes the following tasks: (1) Identification of Health and Environment Impacts derived from the processes, (2) Experimentation to study specific Nanoparticle Emissions, (3) Development of a Risk Management Methodology for the process, and (4) A Comparison of the Health and Environmental Impact of New and Existing Materials. To date, potential exposure scenarios to nanomaterials have been identified through the development of a Preliminary Hazard Analysis (PHA) of the new production processes. In the next step, these scenarios will be studied and simulated to evaluate potential emissions of nanomaterials. Polyfire is a collaborative European project, funded by the European Commission 7th Framework Programme (Grant Agreement No 229220). It features 11 partners from 5 countries (5 SMEs, 3 research institutes, 2 large companies, 1 association) and runs for three years (1st September 2009 - 31st August 2012). This project is an example of an industrial research development which aims to introduce to the market new products promoting the safe use of nanomaterials.

  10. Polyfire project- an example of an industrial research project promoting safe industrial production of fire-resistant nanocomposites

    International Nuclear Information System (INIS)

    Vaquero, C; Lopez de Ipina, J; Galarza, N; Hargreaves, B; Weager, B; Breen, C

    2011-01-01

    New developments based on nanotechnology have to guarantee safe products and processes to be accepted by society. The Polyfire project will develop and scale-up techniques for processing halogen-free, fire-retardant nanocomposite materials and coatings based on unsaturated polyester resins and organoclays. The project includes a work package that will assess the Health and Environmental impacts derived from the manipulation of nanoparticles. This work package includes the following tasks: (1) Identification of Health and Environment Impacts derived from the processes, (2) Experimentation to study specific Nanoparticle Emissions, (3) Development of a Risk Management Methodology for the process, and (4) A Comparison of the Health and Environmental Impact of New and Existing Materials. To date, potential exposure scenarios to nanomaterials have been identified through the development of a Preliminary Hazard Analysis (PHA) of the new production processes. In the next step, these scenarios will be studied and simulated to evaluate potential emissions of nanomaterials. Polyfire is a collaborative European project, funded by the European Commission 7th Framework Programme (Grant Agreement No 229220). It features 11 partners from 5 countries (5 SMEs, 3 research institutes, 2 large companies, 1 association) and runs for three years (1st September 2009 - 31st August 2012). This project is an example of an industrial research development which aims to introduce to the market new products promoting the safe use of nanomaterials.

  11. Design of squat shear walls using continuous strut-and-tie resistant models

    International Nuclear Information System (INIS)

    Santos, S.H. de C; Silva, R.E. da

    1993-01-01

    A new approach is presented for designing squat shear walls, subjected to seismic loading. In this approach, the strut-and-tie resistant models, proposed by Schlaich et al., are generalized in order to analyze continuous fields of compression and tension stresses. The application of the presented methodology is illustrated through numerical examples. (author)

  12. Wildfire ignition resistant home design(WIRHD) program: Full-scale testing and demonstration final report.

    Energy Technology Data Exchange (ETDEWEB)

    Quarles, Stephen, L.; Sindelar, Melissa

    2011-12-13

    The primary goal of the Wildfire ignition resistant home design(WIRHD) program was to develop a home evaluation tool that could assess the ignition potential of a structure subjected to wildfire exposures. This report describes the tests that were conducted, summarizes the results, and discusses the implications of these results with regard to the vulnerabilities to homes and buildings.

  13. Towards appropriate design solutions for drug-resistant TB facilities in SA

    CSIR Research Space (South Africa)

    Parsons, SA

    2010-07-01

    Full Text Available South Africa has a high and increasing burden of both drugs-susceptible and drug-resistant tuberculosis. This disease has been declared an emergency in Africa. South Africa has committed itself to addressing this national crises by designing...

  14. Thermal design and technical economical and environmental analyses of a hydrogen fired multi-objective cogeneration system

    International Nuclear Information System (INIS)

    Durmaz, A; Yilmazoglu, M. Z.; Pasoglu, A.

    2007-01-01

    Approximately 85% of rapidly increasing world energy demand is supplied by fossil fuels. Extreme usage of fossil fuels causes serious global warming and environmental problems in form of air, soil and water pollutions. The period, in which fossil fuel reserves are decreasing, energy costs are increasing rapidly and new energy sources and technologies do not exist on the horizon, can be called as the expensive and critical energy period. Hydrogen becomes a matter of primary importance as a candidate energy source and carrier in the critical energy period and beyond to solve the energy and environmental problems radically. In this respect, the main obstacle for the use of hydrogen is the high cost of hydrogen production, which is expected to be decreased in the feature. The aim of this study is to examine how hydrogen energy will be able to be integrated with the existing energy substructure with technical and economical dimensions. In this sense, a multi objective hydrogen fired gas turbine cogeneration system is designed and optimized. Technical and economical analyses depending on the load conditions and different hydrogen production cost are carried out. It is possible that the co-generated heat is to be marketed for residence and industrial plants in the surrounding at or under market prices. The produced electricity however can only be sold to the public grid at a high unit support price which is only obtainable in case of the development of new energy technologies. This price should however be kept within the nowadays supportable energy price range. The main mechanism to be used during the design stage of the system to achieve this goal is to decrease the amortization and operational costs which lead to decrease investment and fuel costs and to increase the system load factor and co-generated heat revenues

  15. Fire protection

    International Nuclear Information System (INIS)

    Janetzky, E.

    1980-01-01

    Safety and fire prevention measurements have to be treated like the activities developing, planning, construction and erection. Therefore it is necessary that these measurements have to be integrated into the activities mentioned above at an early stage in order to guarantee their effectiveness. With regard to fire accidents the statistics of the insurance companies concerned show that the damage caused increased in the last years mainly due to high concentration of material. Organization of fire prevention and fire fighting, reasons of fire break out, characteristics and behaviour of fire, smoke and fire detection, smoke and heat venting, fire extinguishers (portable and stationary), construction material in presence of fire, respiratory protection etc. will be discussed. (orig./RW)

  16. Seismic design of steel moment resisting frames-European versus American practice

    International Nuclear Information System (INIS)

    Naqash, M.T.; Matteis, G.D.; Luca, A.D.

    2012-01-01

    This paper provides an overview on the design philosophy of moment resisting frames (MRF) according to the seismic provisions of Eurocode 8 and American Institute of Steel Construction (AISC). A synopsis of the main recommendations of the two codes is briefly described. Then in order to examine the structural efficiency of the design principles of MRF according to the aforementioned codes, a case study is developed in which spatial and perimeter moment resisting frames of 12, 6 and 3 storeys residential building are considered. In the case of EC8, Ductility Class Medium (DCM) with behaviour factor of 4 and Ductility Class High (DCH) with behaviour factor of 6.5 for 6-storey frames are used, while only DCH is employed in the design of 12 and 3 storey frames. When dealing with AISC/American Society of Civil Engineers (ASCE) code, special moment resisting frame (SMF) with response modification factor of 8 is employed in the design. The outcomes from the design are illustrated in terms of frame performance, section profiles, strength-demand to capacity ratios, drift-demand to capacity ratios and structural weight, thus allowing the understanding of pros and cons of the design criteria and the capacity design rules of the two codes. The main purpose of the current paper is to compare the seismic design rules of the two codes with a parametric analysis developed by a case study in order to let the technician knows about the importance and influence of some important parameters which are given in the capacity design rules of the two codes. This study will be a benchmark for further analysis on the two codes for seismic design of steel structures. (author)

  17. Fire Perimeters (2012)

    Data.gov (United States)

    Department of Homeland Security — The Geospatial Multi-Agency Coordination Group, or GeoMAC, is an internet-based mapping tool originally designed for fire managers to access online maps of current...

  18. Cable tray fire tests

    International Nuclear Information System (INIS)

    Klamerus, L.J.

    1978-01-01

    Funds were authorized by the Nuclear Regulatory Commission to provide data needed for confirmation of the suitability of current design standards and regulatory guides for fire protection and control in water reactor power plants. The activities of this program through August 1978 are summarized. A survey of industry to determine current design practices and a screening test to select two cable constructions which were used in small scale and full scale testing are described. Both small and full scale tests to assess the adequacy of fire retardant coatings and full scale tests on fire shields to determine their effectiveness are outlined

  19. The designing of launch vehicles with liquid propulsion engines ensuring fire, explosion and environmental safety requirements of worked-off stages

    Science.gov (United States)

    Trushlyakov, V.; Shatrov, Ya.; Sujmenbaev, B.; Baranov, D.

    2017-02-01

    The paper addresses the problem of the launch vehicles (LV) with main liquid propulsion engines launch technogenic impact in different environment areas. Therefore, as the study subjects were chosen the worked-off stages (WS) with unused propellant residues in tanks, the cosmodrome ecological monitoring system, the worked-off stage design and construction solutions development system and the unified system with the "WS+the cosmodrome ecological monitoring system+design and construction solutions development system" feedback allowing to form the optimal ways of the WS design and construction parameters variations for its fire and explosion hazard management in different areas of the environment. It is demonstrated that the fire hazard effects of propellant residues in WS tanks increase the ecosystem disorder level for the Vostochny cosmodrome impact area ecosystem. Applying the system analysis, the proposals on the selection of technologies, schematic and WS design and construction solutions aimed to the fire and explosion safety improvement during the LV worked-off stages with the main liquid propulsion engines operation were formulated. Among them are the following: firstly, the unused propellant residues in tanks convective gasification based on the hot gas (heat carrier) supply in WS tanks after main liquid propulsion engines cutoff is proposed as the basic technology; secondly, the obtained unused propellant residues in WS tanks gasification products (evaporated propellant residues + pressurizing agent + heat carrier) are used for WS stabilization and orientation while descending trajectory moving. The applying of the proposed technologies allows providing fire and explosion safety requirements of LV with main liquid propulsion engines practically.

  20. Moving Aerospace Structural Design Practice to a Load and Resistance Factor Approach

    Science.gov (United States)

    Larsen, Curtis E.; Raju, Ivatury S.

    2016-01-01

    Aerospace structures are traditionally designed using the factor of safety (FOS) approach. The limit load on the structure is determined and the structure is then designed for FOS times the limit load - the ultimate load. Probabilistic approaches utilize distributions for loads and strengths. Failures are predicted to occur in the region of intersection of the two distributions. The load and resistance factor design (LRFD) approach judiciously combines these two approaches by intensive calibration studies on loads and strength to result in structures that are efficient and reliable. This paper discusses these three approaches.

  1. Fire and smoke retardants

    Science.gov (United States)

    Drews, M. J.

    Despite a reduction in Federal regulatory activity, research concerned with flame retardancy and smoke suppression in the private sector appears to be increasing. This trend seem related to the increased utilization of plastics for end uses which traditionally have employed metal or wood products. As a result, new markets have appeared for thermally stable and fire resistance thermoplastic materials, and this in turn has spurred research and development activity. In addition, public awareness of the dangers associated with fire has increased as a result of several highly publicized hotel and restaurant fires within the past two years. The consumers recognition of flammability characteristics as important materials property considerations has increased. The current status of fire and smoke retardant chemistry and research are summarized.

  2. Fire protection in nuclear power plants

    International Nuclear Information System (INIS)

    1979-01-01

    The Safety Guide gives design and some operational guidance for protection from fire and fire-related explosions in nuclear power plants (NPP). It confines itself to fire protection of items important to safety, leaving the aspects of fire protection not related to safety in NPP to be decided upon the basis of the national practices and regulations

  3. 36 CFR 261.52 - Fire.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 2 2010-07-01 2010-07-01 false Fire. 261.52 Section 261.52... in Areas Designated by Order § 261.52 Fire. When provided by an order, the following are prohibited: (a) Building, maintaining, attending or using a fire, campfire, or stove fire. (b) Using an explosive...

  4. Modelling of fire spread in car parks

    NARCIS (Netherlands)

    Noordijk, L.M.; Lemaire, A.D.

    2005-01-01

    Currently, design codes assume that in a car park fire at most 3-4 vehicles are on fire at the same time. Recent incidents in car parks have drawn international attention to such assumptions and have raised questions as to the fire spreading mechanism and the resulting fire load on the structure.

  5. Measuring fire size in tunnels

    International Nuclear Information System (INIS)

    Guo, Xiaoping; Zhang, Qihui

    2013-01-01

    A new measure of fire size Q′ has been introduced in longitudinally ventilated tunnel as the ratio of flame height to the height of tunnel. The analysis in this article has shown that Q′ controls both the critical velocity and the maximum ceiling temperature in the tunnel. Before the fire flame reaches tunnel ceiling (Q′ 1.0), Fr approaches a constant value. This is also a well-known phenomenon in large tunnel fires. Tunnel ceiling temperature shows the opposite trend. Before the fire flame reaches the ceiling, it increases very slowly with the fire size. Once the flame has hit the ceiling of tunnel, temperature rises rapidly with Q′. The good agreement between the current prediction and three different sets of experimental data has demonstrated that the theory has correctly modelled the relation among the heat release rate of fire, ventilation flow and the height of tunnel. From design point of view, the theoretical maximum of critical velocity for a given tunnel can help to prevent oversized ventilation system. -- Highlights: • Fire sizing is an important safety measure in tunnel design. • New measure of fire size a function of HRR of fire, tunnel height and ventilation. • The measure can identify large and small fires. • The characteristics of different fire are consistent with observation in real fires

  6. Fire Stations

    Data.gov (United States)

    Department of Homeland Security — Fire Stations in the United States Any location where fire fighters are stationed or based out of, or where equipment that such personnel use in carrying out their...

  7. Design and Implementation of a Dual-Mass MEMS Gyroscope with High Shock Resistance.

    Science.gov (United States)

    Gao, Yang; Huang, Libin; Ding, Xukai; Li, Hongsheng

    2018-03-30

    This paper presents the design and implementation of a dual-mass MEMS gyroscope with high shock resistance by improving the in-phase frequency of the gyroscope and by using a two-stage elastic stopper mechanism and proposes a Simulink shock model of the gyroscope equipped with the two-stage stopper mechanism, which is a very efficient method to evaluate the shock resistance of the gyroscope. The structural design takes into account both the mechanical sensitivity and the shock resistance. The design of the primary structure and the analysis of the stopper mechanism are first introduced. Based on the expression of the restoring force of the stopper beam, the analytical shock response model of the gyroscope is obtained. By this model, the shock response of the gyroscope is theoretically analyzed, and the appropriate structural parameters are obtained. Then, the correctness of the model is verified by finite element (FE) analysis, where the contact collision analysis is introduced in detail. The simulation results show that the application of the two-stage elastic stopper mechanism can effectively improve the shock resistance by more than 1900 g and 1500 g in the x - and y -directions, respectively. Finally, experimental verifications are carried out by using a machete hammer on the micro-gyroscope prototype fabricated by the deep dry silicon on glass (DDSOG) technology. The results show that the shock resistance of the prototype along the x -, y - and z -axes all exceed 10,000 g. Moreover, the output of the gyroscope can return to normal in about 2 s.

  8. Development of reliability-based load and resistance factor design methods for piping

    International Nuclear Information System (INIS)

    Ayyub, Bilal M.; Hill, Ralph S. III; Balkey, Kenneth R.

    2003-01-01

    Current American Society of Mechanical Engineers (ASME) nuclear codes and standards rely primarily on deterministic and mechanistic approaches to design. The American Institute of Steel Construction and the American Concrete Institute, among other organizations, have incorporated probabilistic methodologies into their design codes. ASME nuclear codes and standards could benefit from developing a probabilistic, reliability-based, design methodology. This paper provides a plan to develop the technical basis for reliability-based, load and resistance factor design of ASME Section III, Class 2/3 piping for primary loading, i.e., pressure, deadweight and seismic. The plan provides a proof of concept in that LRFD can be used in the design of piping, and could achieve consistent reliability levels. Also, the results from future projects in this area could form the basis for code cases, and additional research for piping secondary loads. (author)

  9. The fire brigade renovates

    CERN Multimedia

    2002-01-01

    The new fire engine at CERN's Fire Station. A shiny brand-new fire engine is now attracting all the attention of the members of CERN's fire brigade. Since the beginning of last week this engine has taken over from an 18-year-old one, which has now been 'retired' from service. This modern vehicle, built in Brescia, Italy, is much lighter and more powerful than the old one and is equipped to allow the fire service to tackle most call-outs without the support of at least one other vehicle, as is currently necessary. The new fire engine is designed to transport six fire-fighters, 2000 litres of water, and is equipped not only for fire fighting actions but also to respond initially to any other kind of call-out, such as traffic accidents, chemical incidents, pollution, lightning, etc. It goes almost without saying that it is provided with the most modern safety measures, a low centre of gravity, as well as a special chassis and a combination pump (low and high pressure), which improve the safety and performance ...

  10. Engineering development of advanced coal-fired low-emissions boiler system. Phase II subsystem test design and plan - an addendum to the Phase II RD & T Plan

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    Shortly after the year 2000 it is expected that new generating plants will be needed to meet the growing demand for electricity and to replace the aging plants that are nearing the end of their useful service life. The plants of the future will need to be extremely clean, highly efficient and economical. Continuing concerns over acid rain, air toxics, global climate changes, ozone depletion and solid waste disposal are expected to further then regulations. In the late 1980`s it was commonly believed that coal-fired power plants of the future would incorporate either some form of Integrated Gasification Combined Cycle (IGCC) or first generation Pressurized Fluidized Bed Combustion (PFBS) technologies. However, recent advances In emission control techniques at reduced costs and auxiliary power requirements coupled with significant improvements In steam turbine and cycle design have clearly indicated that pulverized coal technology can continue to be competitive In both cost and performance. In recognition of the competitive potential for advanced pulverized coal-fired systems with other emerging advanced coal-fired technologies, DOE`s Pittsburgh Energy Technology Center (PETC) began a research and development initiative In late 1990 named, Combustion 2000, with the intention of preserving and expanding coal as a principal fuel In the Generation of electrical power. The project was designed for two stages of commercialization, the nearer-term Low Emission Boiler System (LEBS) program, and for the future, the High Performance Power System (HIPPS) program. B&W is participating In the LEBS program.

  11. A wood-waste fuelled, indirectly-fired gas turbine cogeneration plant for sawmill application. Phase 1. Preliminary engineering design and financial evaluation

    Energy Technology Data Exchange (ETDEWEB)

    1986-02-01

    Most sawmills generate more than enough wood waste to be potentially self-sufficient in both dry-kiln heat and electricity requirements. It is not generally economically viable to use conventional steam/electricty cogeneration systems at the sawmill scale of operation. As a result, Canadian sawmills are still large consumers of purchased fuels and electricity. The overall objective of this project was to develop a cost-effective wood waste-fired power generation and lumber drying system for sawmill applications. The system proposed and evaluated in this project is a wood waste-fuelled, indirectly-fired gas turbine cogeneration plant. Research, design, and development of the system has been planned to take place in a number of phases. Phase 1 consists of a preliminary engineering design and financial evaluation of the system, the subjects of this report. The results indicate that the proposed indirectly-fired gas turbine cogeneration system is both technically and financially feasible under a variety of conditions. 8 figs., 8 tabs.

  12. US Fire Administration Fire Statistics

    Data.gov (United States)

    Department of Homeland Security — The U.S. Fire Administration collects data from a variety of sources to provide information and analyses on the status and scope of the fire problem in the United...

  13. Hardware Design of Tuber Electrical Resistance Tomography System Based on the Soil Impedance Test and Analysis

    OpenAIRE

    Liu Shuyi; Deng Xiang; Jiang Zili; Tang Yu

    2016-01-01

    The hardware design of tuber electrical resistance tomography (TERT) system is one of the key research problems of TERT data acquisition system. The TERT system can be applied to the tuber growth process monitoring in agriculture, i.e., the TERT data acquisition system can realize the real imaging of tuber plants in soil. In TERT system, the imaging tuber and soil multiphase medium is quite complexity. So, the impedance test and analysis of soil multiphase medium is very important to the desi...

  14. Sodium fires and its extinguishment

    International Nuclear Information System (INIS)

    Mikhedov, V.G.

    1979-01-01

    The fire safety problems of NPP with sodium coolants in USSR are presented. The design of sodium reactors is made with premises with sodium coolants being hermetic and filled with nitrogen. Some engineering solutions of fire safety including design, elaboration and choice of construction and protection materials are presented. Some theoretical aspects of sodium burning are presented as well as methods of sodium fire extinguishing methods including the use of powder

  15. Design and preliminary evaluation of an exoskeleton for upper limb resistance training

    Science.gov (United States)

    Wu, Tzong-Ming; Chen, Dar-Zen

    2012-06-01

    Resistance training is a popular form of exercise recommended by national health organizations, such as the American College of Sports Medicine (ACSM) and the American Heart Association (AHA). This form of training is available for most populations. A compact design of upper limb exoskeleton mechanism for homebased resistance training using a spring-loaded upper limb exoskeleton with a three degree-of-freedom shoulder joint and a one degree-of-freedom elbow joint allows a patient or a healthy individual to move the upper limb with multiple joints in different planes. It can continuously increase the resistance by adjusting the spring length to train additional muscle groups and reduce the number of potential injuries to upper limb joints caused by the mass moment of inertia of the training equipment. The aim of this research is to perform a preliminary evaluation of the designed function by adopting an appropriate motion analysis system and experimental design to verify our prototype of the exoskeleton and determine the optimal configuration of the spring-loaded upper limb exoskeleton.

  16. Structure-Based Design of Novel HIV-1 Protease Inhibitors to Combat Drug Resistance

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh,A.; Sridhar, P.; Leshchenko, S.; Hussain, A.; Li, J.; Kovalevsky, A.; Walters, D.; Wedelind, J.; Grum-Tokars, V.; et al.

    2006-01-01

    Structure-based design and synthesis of novel HIV protease inhibitors are described. The inhibitors are designed specifically to interact with the backbone of HIV protease active site to combat drug resistance. Inhibitor 3 has exhibited exceedingly potent enzyme inhibitory and antiviral potency. Furthermore, this inhibitor maintains impressive potency against a wide spectrum of HIV including a variety of multi-PI-resistant clinical strains. The inhibitors incorporated a stereochemically defined 5-hexahydrocyclopenta[b]furanyl urethane as the P2-ligand into the (R)-(hydroxyethylamino)sulfonamide isostere. Optically active (3aS,5R,6aR)-5-hydroxy-hexahydrocyclopenta[b]furan was prepared by an enzymatic asymmetrization of meso-diacetate with acetyl cholinesterase, radical cyclization, and Lewis acid-catalyzed anomeric reduction as the key steps. A protein-ligand X-ray crystal structure of inhibitor 3-bound HIV-1 protease (1.35 Angstroms resolution) revealed extensive interactions in the HIV protease active site including strong hydrogen bonding interactions with the backbone. This design strategy may lead to novel inhibitors that can combat drug resistance.

  17. Forest fires

    International Nuclear Information System (INIS)

    Fuller, M.

    1991-01-01

    This book examines the many complex and sensitive issues relating to wildland fires. Beginning with an overview of the fires of 1980s, the book discusses the implications of continued drought and considers the behavior of wildland fires, from ignition and spread to spotting and firestorms. Topics include the effects of weather, forest fuels, fire ecology, and the effects of fire on plants and animals. In addition, the book examines firefighting methods and equipment, including new minimum impact techniques and compressed air foam; prescribed burning; and steps that can be taken to protect individuals and human structures. A history of forest fire policies in the U.S. and a discussion of solutions to fire problems around the world completes the coverage. With one percent of the earth's surface burning every year in the last decade, this is a penetrating book on a subject of undeniable importance

  18. Forest fires in Pennsylvania.

    Science.gov (United States)

    Donald A. Haines; William A. Main; Eugene F. McNamara

    1978-01-01

    Describes factors that contribute to forest fires in Pennsylvania. Includes an analysis of basic statistics; distribution of fires during normal, drought, and wet years; fire cause, fire activity by day-of-week; multiple-fire day; and fire climatology.

  19. 46 CFR 105.35-15 - Fire hose.

    Science.gov (United States)

    2010-10-01

    ... bronze or equivalent metal. (e) All fittings on fire hose shall be of brass, copper, or other suitable corrosion resistant metal. (f) A length of fire hose shall be attached to each fire hydrant at all times... 46 Shipping 4 2010-10-01 2010-10-01 false Fire hose. 105.35-15 Section 105.35-15 Shipping COAST...

  20. 9-12% Cr heat resistant steels. Alloy design, TEM characterisation of microstructure evolution and creep response at 650 C

    Energy Technology Data Exchange (ETDEWEB)

    Rojas Jara, David

    2011-03-21

    This work was carried out aiming to design and characterise 9-12% Cr steels with tailormade microstructures for applications in fossil fuel fired power plants. The investigations concentrated in the design and characterisation of heat resistant steels for applications in high oxidising atmospheres (12% Cr) and 9% Cr alloys for components such as rotors (P91). ThermoCalc calculations showed to be a reliable tool for alloy development. The modeling also provided valuable information for the adjustment of the processing parameters (austenisation and tempering temperatures). Two 12% Cr heat resistant steels with a fine dispersion of nano precipitates were designed and produced supported by thermodynamic modeling (ThermoCalc). A detailed characterisation of the microstructure evolution at different creep times (100 MPa / 650 C / 8000 h) was carried out by scanning transmission electron microscopy (STEM). The results of the microstructure analysis were correlated with the mechanical properties in order to investigate the influence of different precipitates (especially M{sub 23}C{sub 6} carbides) on the creep strength of the alloys. Precipitation of Laves phase and Z-phase was observed after several hundred hours creep time. Very few Z-phase of the type Cr(V,Ta)N nucleating from existing (V,Ta)(C,N) was observed. Both alloys show growth and coarsening of Laves phase, meanwhile the MX carbonitrides present a very slow growth and coarsening rate. Alloys containing Laves phase, MX and M{sub 23}C{sub 6} precipitates show best creep properties. The influence of hot-deformation and tempering temperature on the microstructure evolution on one of the designed 12% Cr alloys was studied during short-term creep at 80-250 MPa and 650 C. Quantitative determination of dislocation density and sub-grain size in the initial microstructure and after creep was investigated by STEM combined with the high-angle annular dark-field detector (HAADF). A correlation between microstructure

  1. 9-12% Cr heat resistant steels. Alloy design, TEM characterisation of microstructure evolution and creep response at 650 C

    International Nuclear Information System (INIS)

    Rojas Jara, David

    2011-01-01

    This work was carried out aiming to design and characterise 9-12% Cr steels with tailormade microstructures for applications in fossil fuel fired power plants. The investigations concentrated in the design and characterisation of heat resistant steels for applications in high oxidising atmospheres (12% Cr) and 9% Cr alloys for components such as rotors (P91). ThermoCalc calculations showed to be a reliable tool for alloy development. The modeling also provided valuable information for the adjustment of the processing parameters (austenisation and tempering temperatures). Two 12% Cr heat resistant steels with a fine dispersion of nano precipitates were designed and produced supported by thermodynamic modeling (ThermoCalc). A detailed characterisation of the microstructure evolution at different creep times (100 MPa / 650 C / 8000 h) was carried out by scanning transmission electron microscopy (STEM). The results of the microstructure analysis were correlated with the mechanical properties in order to investigate the influence of different precipitates (especially M 23 C 6 carbides) on the creep strength of the alloys. Precipitation of Laves phase and Z-phase was observed after several hundred hours creep time. Very few Z-phase of the type Cr(V,Ta)N nucleating from existing (V,Ta)(C,N) was observed. Both alloys show growth and coarsening of Laves phase, meanwhile the MX carbonitrides present a very slow growth and coarsening rate. Alloys containing Laves phase, MX and M 23 C 6 precipitates show best creep properties. The influence of hot-deformation and tempering temperature on the microstructure evolution on one of the designed 12% Cr alloys was studied during short-term creep at 80-250 MPa and 650 C. Quantitative determination of dislocation density and sub-grain size in the initial microstructure and after creep was investigated by STEM combined with the high-angle annular dark-field detector (HAADF). A correlation between microstructure evolution and creep

  2. Design of AN Intelligent Individual Evacuation Model for High Rise Building Fires Based on Neural Network Within the Scope of 3d GIS

    Science.gov (United States)

    Atila, U.; Karas, I. R.; Turan, M. K.; Rahman, A. A.

    2013-09-01

    One of the most dangerous disaster threatening the high rise and complex buildings of today's world including thousands of occupants inside is fire with no doubt. When we consider high population and the complexity of such buildings it is clear to see that performing a rapid and safe evacuation seems hard and human being does not have good memories in case of such disasters like world trade center 9/11. Therefore, it is very important to design knowledge based realtime interactive evacuation methods instead of classical strategies which lack of flexibility. This paper presents a 3D-GIS implementation which simulates the behaviour of an intelligent indoor pedestrian navigation model proposed for a self -evacuation of a person in case of fire. The model is based on Multilayer Perceptron (MLP) which is one of the most preferred artificial neural network architecture in classification and prediction problems. A sample fire scenario following through predefined instructions has been performed on 3D model of the Corporation Complex in Putrajaya (Malaysia) and the intelligent evacuation process has been realized within a proposed 3D-GIS based simulation.

  3. 46 CFR 28.820 - Fire pumps, fire mains, fire hydrants, and fire hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fire pumps, fire mains, fire hydrants, and fire hoses... REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.820 Fire pumps, fire mains, fire hydrants, and fire hoses. (a) Each vessel must be equipped with a self-priming, power driven fire...

  4. Influence of the preparation design and artificial aging on the fracture resistance of monolithic zirconia crowns.

    Science.gov (United States)

    Mitov, Gergo; Anastassova-Yoshida, Yana; Nothdurft, Frank Phillip; von See, Constantin; Pospiech, Peter

    2016-02-01

    The aim of this study was to evaluate the fracture resistance and fracture behavior of monolithic zirconia crowns in accordance with the preparation design and aging simulation method. An upper first molar was prepared sequentially with three different preparation designs: shoulderless preparation, 0.4 mm chamfer and 0.8 mm chamfer preparation. For each preparation design, 30 monolithic zirconia crowns were fabricated. After cementation on Cr-Co alloy dies, the following artificial aging procedures were performed: (1) thermal cycling and mechanical loading (TCML): 5000 cycles of thermal cycling 5℃-55℃ and chewing simulation (1,200,000 cycles, 50 N); (2) Low Temperature Degradation simulation (LTD): autoclave treatment at 137℃, 2 bar for 3 hours and chewing simulation; and (3) no pre-treatment (control group). After artificial aging, the crowns were loaded until fracture. The mean values of fracture resistance varied between 3414 N (LTD; 0.8 mm chamfer preparation) and 5712 N (control group; shoulderless preparation). Two-way ANOVA analysis showed a significantly higher fracture loads for the shoulderless preparation, whereas no difference was found between the chamfer preparations. In contrast to TCML, after LTD simulation the fracture strength of monolithic zirconia crowns decreased significantly. The monolithic crowns tested in this study showed generally high fracture load values. Preparation design and LTD simulation had a significant influence on the fracture strength of monolithic zirconia crowns.

  5. Design and evaluation of a low thermal electromotive force guarded scanner for resistance measurements

    Science.gov (United States)

    Jarrett, Dean G.; Marshall, James A.; Marshall, Thomas A.; Dziuba, Ronald F.

    1999-06-01

    The design and testing of a low thermal electromotive force guarded scanner, developed to provide completely guarded switching when used with actively guarded resistance bridge networks, is described. The design provides a continuous guard circuit trace on the scanner circuit boards that surrounds the relay contacts and protects the measurement circuit from leakages to ground. Modification to the circuit boards and relays of the guarded scanner are explained. Several tests were developed to evaluate the guarding effectiveness, including isolating sections of the guard circuit to create a potential drop between the main and guard circuits. Calibration of standard resistors using the guarded scanner has shown relative differences less than 1×10-6, 30×10-6, and 150×10-6 for measurements made with and without the guarded scanner at nominal resistances of 1, 10, and 100 GΩ, respectively. The substitution method was used to significantly reduce the relative differences between channels to less than 0.5×10-6, 3×10-6, and 30×10-6 for nominal resistances of 1, 10, and 100 GΩ, respectively. Applications for the guarded scanner in automated direct current measurement systems are presented.

  6. Wildland fire limits subsequent fire occurrence

    Science.gov (United States)

    Sean A. Parks; Carol Miller; Lisa M. Holsinger; Scott Baggett; Benjamin J. Bird

    2016-01-01

    Several aspects of wildland fire are moderated by site- and landscape-level vegetation changes caused by previous fire, thereby creating a dynamic where one fire exerts a regulatory control on subsequent fire. For example, wildland fire has been shown to regulate the size and severity of subsequent fire. However, wildland fire has the potential to influence...

  7. Comparison of Chamfer and Deep Chamfer Preparation Designs on the Fracture Resistance of Zirconia Core Restorations

    Directory of Open Access Journals (Sweden)

    Ezatollah Jalalian

    2011-06-01

    Full Text Available Background and aims. One of the major problems of all-ceramic restorations is their probable fracture under occlusal force. The aim of the present in vitro study was to compare the effect of two marginal designs (chamfer and deep chamfer on the fracture resistance of all-ceramic restorations, CERCON. Materials and methods. This in vitro study was carried out with single-blind experimental technique. One stainless steel die with 50’ chamfer finish line design (0.8 mm deep was prepared using a milling machine. Ten epoxy resin dies were prepared. The same die was retrieved and 50' chamfer was converted into a deep chamfer design (1 mm. Again ten epoxy resin dies were prepared from the deep chamfer die. Zirconia cores with 0.4 mm thickness and 35 µm cement space were fabricated on the epoxy resin dies (10 chamfer and 10 deep chamfer samples. The zirconia cores were cemented on the epoxy resin dies and underwent a fracture test with a universal testing machine and the samples were investigated from the point of view of the origin of the failure. Results. The mean values of fracture resistance for deep chamfer and chamfer samples were 1426.10±182.60 and 991.75±112.00 N, respectively. Student’s t-test revealed statistically significant differences between the groups. Conclusion. The results indicated a relationship between the marginal design of zirconia cores and their fracture resistance. A deep chamfer margin improved the biomechanical performance of posterior single zirconia crown restorations, which might be attributed to greater thickness and rounded internal angles in deep chamfer margins.

  8. Fire test database

    International Nuclear Information System (INIS)

    Lee, J.A.

    1989-01-01

    This paper describes a project recently completed for EPRI by Impell. The purpose of the project was to develop a reference database of fire tests performed on non-typical fire rated assemblies. The database is designed for use by utility fire protection engineers to locate test reports for power plant fire rated assemblies. As utilities prepare to respond to Information Notice 88-04, the database will identify utilities, vendors or manufacturers who have specific fire test data. The database contains fire test report summaries for 729 tested configurations. For each summary, a contact is identified from whom a copy of the complete fire test report can be obtained. Five types of configurations are included: doors, dampers, seals, wraps and walls. The database is computerized. One version for IBM; one for Mac. Each database is accessed through user-friendly software which allows adding, deleting, browsing, etc. through the database. There are five major database files. One each for the five types of tested configurations. The contents of each provides significant information regarding the test method and the physical attributes of the tested configuration. 3 figs

  9. CMOS sensors in 90 nm fabricated on high resistivity wafers: Design concept and irradiation results

    International Nuclear Information System (INIS)

    Rivetti, A.; Battaglia, M.; Bisello, D.; Caselle, M.; Chalmet, P.; Costa, M.; Demaria, N.; Giubilato, P.; Ikemoto, Y.; Kloukinas, K.; Mansuy, C.; Marchioro, A.; Mugnier, H.; Pantano, D.; Potenza, A.; Rousset, J.; Silvestrin, L.; Wyss, J.

    2013-01-01

    The LePix project aims at improving the radiation hardness and the readout speed of monolithic CMOS sensors through the use of standard CMOS technologies fabricated on high resistivity substrates. In this context, high resistivity means beyond 400Ωcm, which is at least one order of magnitude greater than the typical value (1–10Ωcm) adopted for integrated circuit production. The possibility of employing these lightly doped substrates was offered by one foundry for an otherwise standard 90 nm CMOS process. In the paper, the case for such a development is first discussed. The sensor design is then described, along with the key challenges encountered in fabricating the detecting element in a very deep submicron process. Finally, irradiation results obtained on test matrices are reported

  10. Design of high-speed planing hulls for the improvement of resistance and seakeeping performance

    Directory of Open Access Journals (Sweden)

    Dong Jin Kim

    2013-03-01

    Full Text Available High-speed vessels require good resistance and seakeeping performance for safe operations in rough seas. The resistance and seakeeping performance of high-speed vessels varies significantly depending on their hull forms. In this study, three planing hulls that have almost the same displacement and principal dimension are designed and the hydrodynamic characteristics of those hulls are estimated by high-speed model tests. All model ships are deep-V type planing hulls. The bows of no.2 and no.3 model ships are designed to be advantageous for wave-piercing in rough water. No. 2 and no. 3 model ships have concave and straight forebody cross-sections, respectively. And length-to-beam ratios of no.2 and no.3 models are larger than that of no.1 model. In calm water tests, running attitude and resistance of model ships are measured at various speeds. And motion tests in regular waves are performed to measure the heave and pitch motion responses of the model ships. The required power of no.1 (VPS model is smallest, but its vertical motion amplitudes in waves are the largest. No.2 (VWC model shows the smallest motion amplitudes in waves, but needs the greatest power at high speed. The resistance and seakeeping performance of no.3 (VWS model ship are the middle of three model ships, respectively. And in regular waves, no.1 model ship experiences ‘fly over’ phenomena around its resonant frequency. Vertical accelerations at specific locations such as F.P., center of gravity of model ships are measured at their resonant frequency. It is necessary to measure accelerations by accelerometers or other devices in model tests for the accurate prediction of vertical accelerations in real ships.

  11. Evaluation of factors that affect rutting resistance of asphalt mixes by orthogonal experiment design

    Directory of Open Access Journals (Sweden)

    Guilian Zou

    2017-05-01

    Full Text Available Rutting has been one of the major distresses observed on asphalt pavement in China, due to increasing traffic volume, heavy axle load, continuous hot weather, etc., especially in long-steep-slope section, bus stops, etc. Many factors would affect rutting resistance of asphalt pavement, including material properties, climatic condition, traffic volumes, speed, and axle types, and construction quality.The orthogonal experimental design method was used in this study to reduce the number of tests required, without comprising the validity of the test results. The testing variables and their levels were selected according to investigations and field test results. Effects of various factors on asphalt pavement rutting performance were evaluated, including the asphalt binders, mixture type (aggregate gradation, axle load, vehicle speed and temperature.In this study, the wheel tracking test was used to evaluate rutting performance, as represented by the parameter Dynamic Stability (DS, of the various asphalt mixes. Test results were analyzed using range analysis and analysis of variance (ANOVA. All four factors evaluated in this study had significant effects on pavement rutting performance. The ranking of the significance was asphalt mixture type, temperature, loading frequency, and tire-pavement contact pressure. Asphalt mixture type was the most important factor that affects rutting resistance. Within the asphalt mixtures, asphalt binder had significant effects on rutting performance of mixes more than aggregate gradation. Rutting resistance of SBS modified asphalt mixes was significantly better than neat asphalt mixes, and skeleton dense structure mixes were better than suspended dense structure mixes. Keywords: Asphalt mixes, Rutting resistance, Effect factor, Orthogonal experiment design

  12. 14 CFR 33.17 - Fire protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection. 33.17 Section 33.17... STANDARDS: AIRCRAFT ENGINES Design and Construction; General § 33.17 Fire protection. (a) The design and... protection unless damage by fire will not cause leakage or spillage of a hazardous quantity of flammable...

  13. Evaluation of the Internal and Borehole Resistances during Thermal Response Tests and Impact on Ground Heat Exchanger Design

    Directory of Open Access Journals (Sweden)

    Louis Lamarche

    2017-12-01

    Full Text Available The main parameters evaluated with a conventional thermal response test (TRT are the subsurface thermal conductivity surrounding the borehole and the effective borehole thermal resistance, when averaging the inlet and outlet temperature of a ground heat exchanger with the arithmetic mean. This effective resistance depends on two resistances: the 2D borehole resistance (Rb and the 2D internal resistance (Ra which is associated to the short-circuit effect between pipes in the borehole. This paper presents a field method to evaluate these two components separately. Two approaches are proposed. In the first case, the temperature at the bottom of the borehole is measured at the same time as the inlet and outlet temperatures as done in a conventional TRT. In the second case, different flow rates are used during the experiment to infer the internal resistance. Both approaches assumed a predefined temperature profile inside the borehole. The methods were applied to real experimental tests and compared with numerical simulations. Interesting results were found by comparison with theoretical resistances calculated with the multipole method. The motivation for this work is evidenced by analyzing the impact of the internal resistance on a typical geothermal system design. It is shown to be important to know both resistance components to predict the variation of the effective resistance when the flow rate and the height of the boreholes are changed during the design process.

  14. Temporary fire sealing of penetrations on TFTR

    International Nuclear Information System (INIS)

    Hondorp, H.L.

    1981-02-01

    The radiation shielding provided for TFTR for D-D and D-T operation will be penetrated by numerous electrical and mechanical services. Eventually, these penetrations will have to be sealed to provide the required fire resistance, tritium sealability, pressure integrity and radiation attenuation. For the initial hydrogen operation, however, fire sealing of the penetrations in the walls and floor is the primary concern. This report provides a discussion of the required and desirable properties of a temporary seal which can be used to seal these penetrations for the hydrogen operation and then subsequently be removed and replaced as required for the D-D and D-T operations. Several candidate designs are discussed and evaluated and recommendations are made for specific applications

  15. Standpipe systems for fire protection

    CERN Document Server

    Isman, Kenneth E

    2017-01-01

    This important new manual goes beyond the published NFPA standards on installation of standpipe systems to include the rules in the International Building Code, municipal fire codes, the National Fire Code of Canada, and information on inspection, testing, and maintenance of standpipe systems. Also covered are the interactions between standpipe and sprinkler systems, since these important fire protection systems are so frequently installed together. Illustrated with design examples and practical applications to reinforce the learning experience, this is the go-to reference for engineers, architects, design technicians, building inspectors, fire inspectors, and anyone that inspects, tests or maintains fire protection systems. Fire marshals and plan review authorities that have the responsibility for reviewing and accepting plans and hydraulic calculations for standpipe systems are also an important audience, as are firefighters who actually use standpipe systems. As a member of the committees responsible for s...

  16. Optimum design of matrix fault current limiters using the series resistance connected with shunt coil

    Science.gov (United States)

    Chung, D. C.; Choi, H. S.; Lee, N. Y.; Nam, G. Y.; Cho, Y. S.; Sung, T. H.; Han, Y. H.; Kim, B. S.; Lim, S. H.

    2007-10-01

    In this paper we described the improved design for the matrix fault current limiters (MFCL). To do this, we used thin film-type superconducting elements. therefore it means that we can make the MFCL with minimized size and high switching speed because of the high current density and the high indexing value of superconducting thin film. Also we could minimize the bulky shunt coil using the connection of a series resistance with a shunt coil. Also we could effectively block up a leakage current in shunt coils under no-fault condition and simply control total impedances of a current-limiting part using this method. After we designed an appropriated 1 × 2 basic MFCL module with an applied voltage of 160 V, we enlarged it to a 2 × 2 MFCL module and a 3 × 2 MFCL module where applied voltages were 320 V and 480 V, respectively. Experimental results for our MFCL were reported in terms of various fault currents, variation of series resistance and so on. We think that these methods will be useful in the optimum design of an m × n MFCL.

  17. Optimum design of matrix fault current limiters using the series resistance connected with shunt coil

    International Nuclear Information System (INIS)

    Chung, D.C.; Choi, H.S.; Lee, N.Y.; Nam, G.Y.; Cho, Y.S.; Sung, T.H.; Han, Y.H.; Kim, B.S.; Lim, S.H.

    2007-01-01

    In this paper we described the improved design for the matrix fault current limiters (MFCL). To do this, we used thin film-type superconducting elements. therefore it means that we can make the MFCL with minimized size and high switching speed because of the high current density and the high indexing value of superconducting thin film. Also we could minimize the bulky shunt coil using the connection of a series resistance with a shunt coil. Also we could effectively block up a leakage current in shunt coils under no-fault condition and simply control total impedances of a current-limiting part using this method. After we designed an appropriated 1 x 2 basic MFCL module with an applied voltage of 160 V, we enlarged it to a 2 x 2 MFCL module and a 3 x 2 MFCL module where applied voltages were 320 V and 480 V, respectively. Experimental results for our MFCL were reported in terms of various fault currents, variation of series resistance and so on. We think that these methods will be useful in the optimum design of an m x n MFCL

  18. Comparison of cyclic fatigue resistance of three different rotary nickel-titanium instruments designed for retreatment.

    Science.gov (United States)

    Inan, Ugur; Aydin, Cumhur

    2012-01-01

    A number of rotary nickel-titanium (NiTi) systems have been developed to provide better, faster, and easier cleaning and shaping of the root canal system, and recently, rotary NiTi systems designed for root canal retreatment have been introduced. Because the main problem with the rotary NiTi files is fracture, the aim of this study was to compare the cyclic fatigue resistance of 3 different rotary NiTi systems designed for root canal retreatment. Total of 60 instruments of 3 different rotary NiTi systems designed for root canal retreatment were used in this study. Twenty R-Endo R3, 20 ProTaper D3, and 20 Mtwo R (Retreatment) 25.05 instruments were tested. Cyclic fatigue testing of instruments was performed by using a device that allowed the instruments to rotate freely inside an artificial canal. Each instrument was rotated until fracture occurred, and the number of cycles to fracture for each instrument was calculated. Representative samples were also evaluated under a scanning electron microscope to confirm the fracture was flexural. Data were analyzed by using 1-way analysis of variance test. R-Endo R3 instruments showed better cyclic fatigue resistance than ProTaper D3 and Mtwo R 25.05 instruments, and the difference was statistically significant (P instruments were more resistant to fatigue failure than ProTaper D3 and Mtwo R 25.05. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. [Fracture resistance of Procera Allceram depending on the framework design--an in vitro study].

    Science.gov (United States)

    Hagmann, Edgar; Marinello, Carlo P; Zitzmann, Nicola U

    2006-01-01

    Procera AllCeram is one of the all-ceramic systems with an aluminium-oxide core employing CAD/CAM technology. The aim of the current study was to investigate the fracture resistance of Procera AllCeram full-ceramic crowns with a reduced core design compared to the conventional method. In addition, a possible influence of the preparation form (molars or premolars) and the cementation material (glas-ionomer or composite) was analyzed. For both preparation forms, 30 ceramic cores with reduced margins (collarless cores, test) and 30 cores with extended cores (control) were veneered with porcelain in a standardized procedure (total 120 crowns). For the test group, Procera-AllCeram-margin ceramic material was used for the porcelain collar. 40 crowns each were cemented on stainless steel dies with either Ketac-Cem Aplicap or Panavia F. The additional 40 crowns were set on polyurethane dies without cementation and occlusally loaded until fracture occurred. Among the molar crowns, no differences were observed in fracture resistance neither for the different core designs (test or control) nor for the cementation materials. For the premolar form, fusing of a porcelain margin was associated with a reduction in fracture resistance, while the use of composite cement was accompanied with an increase. The present in vitro results indicate that for Procera AllCeram crowns with a highly undulating preparation margin, a conventional core design combined with adhesive cementation is preferable, especially in the posterior region due to higher chewing forces; this assumption needs to be proven in clinical studies.

  20. Application Study of Fire Severity Classification

    International Nuclear Information System (INIS)

    Kim, In Hwan; Kim, Hyeong Taek; Jee, Moon Hak; Kim, Yun Jung

    2013-01-01

    This paper introduces the Fire Incidents Severity Classification Method for Korean NPPs that may be derived directly from the data fields and feasibility study for domestic uses. FEDB was characterized in more detail and assessed based on the significance of fire incidents in the updated database and five fire severity categories were defined. The logical approach to determine the fire severity starts from the most severe characteristics, namely challenging fires, and continues to define the less challenging and undetermined categories in progress. If the FEDB is utilized for Korean NPPs, the ways of Fire Severity Classification suggested in 2.4 above can be utilized for the quantitative fire risk analysis in future. The Fire Events Database (FEDB) is the primary source of fire data which are used for fire frequency in Fire PSA (Probabilistic Safety Assessment). The purpose of its development is to calculate the quantitative fire frequency at the comprehensive and consolidated source derived from the fire incident information available for Nuclear Power Plants (NPPs). Recently, the Fire Events Database (FEDB) was updated by Electric Power Research Institute (EPRI) and Nuclear Regulatory Commission (NRC) in U. S. The FEDB is intended to update the fire event history up to 2009. A significant enhancement to it is the reorganization and refinement of the database structure and data fields. It has been expanded and improved data fields, coding consistency, incident detail, data review fields, and reference data source traceability. It has been designed to better support several Fire PRA uses as well

  1. Numerical Investigation of Progressive Collapse Resistance for Seismically Designed RC Buildings

    OpenAIRE

    Marchiş, Adrian G.; Ioani, Adrian M.

    2014-01-01

    In this paper the progressive collapse behavior of a reinforced concrete framed building located in different seismic areas from Romania is investigated. The six-storey structure is designed for low (ag = 0.08 g), moderate (ag = 0.16 g) and high (ag = 0.24 g) seismic zone. Based on the GSA (2003) criteria, a nonlinear static analysis is conducted first in order to estimate the progressive collapse resistance of the models. It was shown that all the structures will collapse when subjected to i...

  2. Differences in the motor unit firing rates and amplitudes in relation to recruitment thresholds during submaximal contractions of the first dorsal interosseous between chronically resistance trained and physically active men.

    Science.gov (United States)

    Sterczala, Adam J; Miller, Jonathan D; Trevino, Michael A; Dimmick, Hannah L; Herda, Trent J

    2018-02-26

    Previous investigations report no changes in motor unit (MU) firing rates during submaximal contractions following resistance training. These investigations did not account for MU recruitment or examine firing rates as a function of recruitment threshold (REC).Therefore, MU recruitment and firing rates in chronically resistance trained (RT) and physically active controls (CON) were examined. Surface electromyography signals were collected from the first dorsal interosseous (FDI) during isometric muscle actions at 40% and 70% maximal voluntary contraction (MVC). For each MU, force at REC, mean firing rate (MFR) during the steady force, and MU action potential amplitude (MUAPAMP) were analyzed. For each individual and contraction, the MFRs were linearly regressed against REC, whereas, exponential models were applied to the MFR vs. MUAPAMP and MUAPAMP vs. REC relationships with the y-intercepts and slopes (linear) and A and B terms (exponential) calculated. For the 40% MVC, the RT group had less negative slopes (p=0.001) and lower y-intercepts (p=0.006) of the MFR vs. REC relationships and lower B terms (p=0.011) of the MUAPAMP vs. REC relationships. There were no differences in either relationship between groups for the 70% MVC. During the 40% MVC, the RT had a smaller range of MFRs and MUAPAMPS in comparison to the CON, likely due to reduced MU recruitment. The RT had lower MFRs and recruitment during the 40% MVC that may indicate a leftward shift in the force-frequency relationship, and thus require less excitation to the motoneuron pool to match the same relative force.

  3. Development of a Midscale Test for Flame Resistant Protection

    Science.gov (United States)

    2016-08-01

    Evaluation of Flame Resistant Clothing for Protection against Fire Simulations Using an Instrumented Manikin, which provides both radiant and convective heat...TEST METHODS FIRE RESISTANT MATERIALS TORCHES SIMULATION TEST EQUIPMENT FLAME RESISTANT CLOTHING PERFORMANCE(ENGINEERING... fabric during a fire , and even after the fire has been extinguished. The best known full scale transmitted heat flux test is the "ASTM F1930

  4. The development of fire detection robot

    OpenAIRE

    Sucuoğlu, Hilmi Saygın

    2015-01-01

    The aim of this thesis is to design and manufacture a fire detection robot that especially operates in industrial areas for fire inspection and early detection. Robot is designed and implemented to track prescribed paths with obstacle avoidance function through obstacle avoidance and motion planning units and to scan the environment in order to detect fire source using fire detection unit. Robot is able to track patrolling routes using virtual lines that defined to the motion planning unit. ...

  5. Design of a new bottom antireflective coating composition for KrF resist

    Science.gov (United States)

    Mizutani, Kazuyoshi; Momota, Makoto; Aoai, Toshiaki; Yagihara, Morio

    1999-06-01

    A study for a new organic bottom antireflective coating (BARC) composition is described. A structural design of a light-absorbing dye was most important because dye structure not only plays a role in eliminating reflection from a substrate but also shows influence on dry etch rate of BARC material to a considerable extent. For example, an anthracene moiety with large absorption at 248 nm had undesirable dry etch resistance. 3-Hydroxy-2-naphthoic acid moiety was found to be one of suitable dyes for KrF BARC compositions, and the polymer bearing the dye showed enough absorbance and good erodability in dry etch. The BARC polymer was eroded as one and a half times faster than a novolak resin, and a little faster than an anthracene incorporated polymer. The result was discussed from the concepts of Ohnishi parameter and the ring parameter for dry etch durability of resist materials. BARC polymer should be thermoset by hard bake to eliminate intermixing with resist compositions. The BARC polymer bearing hydroxy group which is useful for a crosslinking reaction was thermoset in the presence of melamine-formaldehyde crosslinker and an acid catalyst after baking over 200 degrees C.

  6. Performance of a Heating Block System Designed for Studying the Heat Resistance of Bacteria in Foods

    Science.gov (United States)

    Kou, Xiao-xi; Li, Rui; Hou, Li-xia; Huang, Zhi; Ling, Bo; Wang, Shao-jin

    2016-01-01

    Knowledge of bacteria’s heat resistance is essential for developing effective thermal treatments. Choosing an appropriate test method is important to accurately determine bacteria’s heat resistances. Although being a major factor to influence the thermo-tolerance of bacteria, the heating rate in samples cannot be controlled in water or oil bath methods due to main dependence on sample’s thermal properties. A heating block system (HBS) was designed to regulate the heating rates in liquid, semi-solid and solid foods using a temperature controller. Distilled water, apple juice, mashed potato, almond powder and beef were selected to evaluate the HBS’s performance by experiment and computer simulation. The results showed that the heating rates of 1, 5 and 10 °C/min with final set-point temperatures and holding times could be easily and precisely achieved in five selected food materials. A good agreement in sample central temperature profiles was obtained under various heating rates between experiment and simulation. The experimental and simulated results showed that the HBS could provide a sufficiently uniform heating environment in food samples. The effect of heating rate on bacterial thermal resistance was evaluated with the HBS. The system may hold potential applications for rapid and accurate assessments of bacteria’s thermo-tolerances. PMID:27465120

  7. A STUDY ON THE EARTHQUAKE RESPONSE AND EARTHQUAKE RESISTANT DESIGN METHOD OF AN OPEN TYPE WHARF WITH PNEUMATIC CAISSONS

    Science.gov (United States)

    Oishi, Masahiko; Nagao, Takashi; Shigeki, Kouji; Ouchi, Masatoshi; Sato, Yuske; Kinomiya, Osamu

    Seismic response of an open type wharf with pneumatic caisson was clarified using a dynamic finite element method. As a result, rocking behavior of caisson foundations were observed and applicability of a frame model analysis to the earthquake resistant design of a wharf was suggested. Authors proposed the framework of earthquake resistant design method of the wharf including the evaluation method of response acceleration of the wharf.

  8. Methodology for developing and implementing alternative temperature-time curves for testing the fire resistance of barriers for nuclear power plant applications

    International Nuclear Information System (INIS)

    Cooper, L.Y.; Steckler, K.D.

    1996-08-01

    Advances in fire science over the past 40 years have offered the potential for developing technically sound alternative temperature-time curves for use in evaluating fire barriers for areas where fire exposures can be expected to be significantly different than the ASTM E-119 standard temperature-time exposure. This report summarizes the development of the ASTM E-119, standard temperature-time curve, and the efforts by the federal government and the petrochemical industry to develop alternative fire endurance curves for specific applications. The report also provides a framework for the development of alternative curves for application at nuclear power plants. The staff has concluded that in view of the effort necessary for the development of nuclear power plant specific temperature-time curves, such curves are not a viable approach for resolving the issues concerning Thermo-Lag fire barriers. However, the approach may be useful to licensees in the development of performance-based fire protection methods in the future

  9. Methodology for developing and implementing alternative temperature-time curves for testing the fire resistance of barriers for nuclear power plant applications

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, L.Y.; Steckler, K.D.

    1996-08-01

    Advances in fire science over the past 40 years have offered the potential for developing technically sound alternative temperature-time curves for use in evaluating fire barriers for areas where fire exposures can be expected to be significantly different than the ASTM E-119 standard temperature-time exposure. This report summarizes the development of the ASTM E-119, standard temperature-time curve, and the efforts by the federal government and the petrochemical industry to develop alternative fire endurance curves for specific applications. The report also provides a framework for the development of alternative curves for application at nuclear power plants. The staff has concluded that in view of the effort necessary for the development of nuclear power plant specific temperature-time curves, such curves are not a viable approach for resolving the issues concerning Thermo-Lag fire barriers. However, the approach may be useful to licensees in the development of performance-based fire protection methods in the future.

  10. Fire Resistant Aircraft Hydraulic System.

    Science.gov (United States)

    1982-07-01

    Chemical Division "Fluorinert" FC-48 - Fluorinated Hydrocarbon "Fluorinert" FC-70 - Fluorinated Hydrocarbon Montedison S. p. A. "Fomblin" Z-04...forming substances such as varnish which could seize a spool valve or other small-clearance sliding surfaces. The test setup is pictorially described in...breakdown products such as solid particles, gels, and sludge’can plug system filters and even small fluid passages, nozzles, and orifices. Varnish -like

  11. Examination of alternatives to upgrade fire safety in operating NPPs

    International Nuclear Information System (INIS)

    Park, J. H.; Jung, I. S.

    2003-01-01

    For the Kori unit 2,3,4, Younggwang 1,2 and Ulchin 1,2 fire protection vulnerabilities and further improvement items are investigated. The most major problem is that those plants do not have plant-specific Fire Hazard Analysis Report. To improve fire safety of those plants, their own Fire Hazard Analysis should be proceed at first. Then, according to results of Fire Hazard Analysis, fire protection improvement program should be implemented. For the assurance of long term fire safety, result of Fire Hazard Analysis should be incorporated in the FSAR and periodically reviewed the impact of design change to fire safety

  12. On fire

    DEFF Research Database (Denmark)

    Hansen, Helle Rabøl

    The title of this paper: “On fire”, refers to two (maybe three) aspects: firstly as a metaphor of having engagement in a community of practice according to Lave & Wenger (1991), and secondly it refers to the concrete element “fire” in the work of the fire fighters – and thirdly fire as a signifier...

  13. Fire Power

    Science.gov (United States)

    Denker, Deb; West, Lee

    2009-01-01

    For education administrators, campus fires are not only a distressing loss, but also a stark reminder that a campus faces risks that require special vigilance. In many ways, campuses resemble small communities, with areas for living, working and relaxing. A residence hall fire may raise the specter of careless youth, often with the complication of…

  14. 46 CFR 28.315 - Fire pumps, fire mains, fire hydrants, and fire hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fire pumps, fire mains, fire hydrants, and fire hoses... After September 15, 1991, and That Operate With More Than 16 Individuals on Board § 28.315 Fire pumps, fire mains, fire hydrants, and fire hoses. (a) Each vessel 36 feet (11.8 meters) or more in length must...

  15. Forest-fire models

    Science.gov (United States)

    Haiganoush Preisler; Alan Ager

    2013-01-01

    For applied mathematicians forest fire models refer mainly to a non-linear dynamic system often used to simulate spread of fire. For forest managers forest fire models may pertain to any of the three phases of fire management: prefire planning (fire risk models), fire suppression (fire behavior models), and postfire evaluation (fire effects and economic models). In...

  16. Hardware Design of Tuber Electrical Resistance Tomography System Based on the Soil Impedance Test and Analysis

    Directory of Open Access Journals (Sweden)

    Liu Shuyi

    2016-01-01

    Full Text Available The hardware design of tuber electrical resistance tomography (TERT system is one of the key research problems of TERT data acquisition system. The TERT system can be applied to the tuber growth process monitoring in agriculture, i.e., the TERT data acquisition system can realize the real imaging of tuber plants in soil. In TERT system, the imaging tuber and soil multiphase medium is quite complexity. So, the impedance test and analysis of soil multiphase medium is very important to the design of sensitive array sensor subsystem and signals processing circuits. In the paper, the soil impedance test experimental is described and the results are analysed. The data acquisition hardware system is designed based on the result of soil medium impedance test and analysis. In the hardware design, the switch control chip ADG508, the instrumentation amplifier AD620 and programmable amplifier AD526 are employed. In the meantime, the phase locked loop technique for signal demodulation is introduced. The initial data collection is given and discussed under the conditions of existing plant tuber and no existing plant tuber. Conclusions of the hardware design of TERT system are presented.

  17. Conceptual design of a versatile radiation tolerant integrated signal conditioning circuit for resistive sensors

    Energy Technology Data Exchange (ETDEWEB)

    Leroux, P. [Katholieke Hogeschool Kempen, Kleinhoefstraat 4, B-2440 Geel (Belgium); Katholieke Universiteit Leuven, Dept. ESAT-MICAS, Kasteelpark Arenberg 10, B-3001 Heverlee (Belgium); SCK-CEN, Belgian Nuclear Research Centre, Boeretang 200, B-2400 Mol (Belgium); Sterckx, J. [Katholieke Hogeschool Kempen, Kleinhoefstraat 4, B-2440 Geel (Belgium); Van Uffelen, M.; Damiani, C. [Fusion 4 Energy, Ed. B3, c/Josep, no 2, Torres Diagonal Litoral, 08019 Barcelona (Spain)

    2011-07-01

    This paper presents the design of a radiation tolerant configurable discrete time CMOS signal conditioning circuit for use with resistive sensors like strain gauge pressure sensors. The circuit is intended to be used for remote handling in harsh environments in the International Thermonuclear Experimental fusion Reactor (ITER). The design features a 5 V differential preamplifier using a Correlated Double Sampling (CDS) architecture at a sample rate of 20 kHz and a 24 V discrete time post amplifier. The gain is digitally controllable between 27 and 400 in the preamplifier and between 1 and 8 in the post amplifier. The nominal input referred noise voltage is only 8.5 {mu}V while consuming only 1 mW. The circuit has a simulated radiation tolerance of more than 1 MGy. (authors)

  18. Characterization of potential fire regimes: applying landscape ecology to fire management in Mexico

    Science.gov (United States)

    Jardel, E.; Alvarado, E.; Perez-Salicrup, D.; Morfín-Rios, J.

    2013-05-01

    Knowledge and understanding of fire regimes is fundamental to design sound fire management practices. The high ecosystem diversity of Mexico offers a great challenge to characterize the fire regime variation at the landscape level. A conceptual model was developed considering the main factors controlling fire regimes: climate and vegetation cover. We classified landscape units combining bioclimatic zones from the Holdridge life-zone system and actual vegetation cover. Since bioclimatic conditions control primary productivity and biomass accumulation (potential fuel), each landscape unit was considered as a fuel bed with a particular fire intensity and behavior potential. Climate is also a determinant factor of post-fire recovery rates of fuel beds, and climate seasonality (length of the dry and wet seasons) influences fire probability (available fuel and ignition efficiency). These two factors influence potential fire frequency. Potential fire severity can be inferred from fire frequency, fire intensity and behavior, and vegetation composition and structure. Based in the conceptual model, an exhaustive literature review and expert opinion, we developed rules to assign a potential fire regime (PFR) defined by frequency, intensity and severity (i.e. fire regime) to each bioclimatic-vegetation landscape unit. Three groups and eight types of potential fire regimes were identified. In Group A are fire-prone ecosystems with frequent low severity surface fires in grasslands (PFR type I) or forests with long dry season (II) and infrequent high-severity fires in chaparral (III), wet temperate forests (IV, fire restricted by humidity), and dry temperate forests (V, fire restricted by fuel recovery rate). Group B includes fire-reluctant ecosystems with very infrequent or occasional mixed severity surface fires limited by moisture in tropical rain forests (VI) or fuel availability in seasonally dry tropical forests (VII). Group C and PFR VIII include fire-free environments

  19. Design and optimization of resistance wire electric heater for hypersonic wind tunnel

    Science.gov (United States)

    Rehman, Khurram; Malik, Afzaal M.; Khan, I. J.; Hassan, Jehangir

    2012-06-01

    The range of flow velocities of high speed wind tunnels varies from Mach 1.0 to hypersonic order. In order to achieve such high speed flows, a high expansion nozzle is employed in the converging-diverging section of wind tunnel nozzle. The air for flow is compressed and stored in pressure vessels at temperatures close to ambient conditions. The stored air is dried and has minimum amount of moisture level. However, when this air is expanded rapidly, its temperature drops significantly and liquefaction conditions can be encountered. Air at near room temperature will liquefy due to expansion cooling at a flow velocity of more than Mach 4.0 in a wind tunnel test section. Such liquefaction may not only be hazardous to the model under test and wind tunnel structure; it may also affect the test results. In order to avoid liquefaction of air, a pre-heater is employed in between the pressure vessel and the converging-diverging section of a wind tunnel. A number of techniques are being used for heating the flow in high speed wind tunnels. Some of these include the electric arc heating, pebble bed electric heating, pebble bed natural gas fired heater, hydrogen burner heater, and the laser heater mechanisms. The most common are the pebble bed storage type heaters, which are inefficient, contaminating and time consuming. A well designed electrically heating system can be efficient, clean and simple in operation, for accelerating the wind tunnel flow up to Mach 10. This paper presents CFD analysis of electric preheater for different configurations to optimize its design. This analysis has been done using ANSYS 12.1 FLUENT package while geometry and meshing was done in GAMBIT.

  20. 30 CFR 75.1107-6 - Capacity of fire suppression devices; location and direction of nozzles.

    Science.gov (United States)

    2010-07-01

    ... nozzles of each fire suppression device shall, where practicable, be located so as to take advantage of... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Capacity of fire suppression devices; location... Fire Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment...

  1. Computational design and performance prediction of creep-resistant ferritic superalloys

    Energy Technology Data Exchange (ETDEWEB)

    Liaw, Peter K. [Univ. of Tennessee, Knoxville, TN (United States); Wang, Shao-Yu [Univ. of Tennessee, Knoxville, TN (United States); Dunand, David C. [Northwestern Univ., Evanston, IL (United States); Ghosh, Gautum [Northwestern Univ., Evanston, IL (United States); Song, Gian [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rawlings, Michael [Univ. of Tennessee, Knoxville, TN (United States); Baik, Sung Il [Northwestern Univ., Evanston, IL (United States)

    2017-12-04

    Ferritic superalloys containing the B2 phase with the parent L21 phase precipitates in a disordered solid-solution matrix, also known as a hierarchical-precipitate-strengthened ferritic alloy (HPSFA), had been developed for high-temperature structural applications in fossil-energy power plants. These alloys were designed by adding Ti into a previously-studied NiAl-strengthened ferritic alloy (denoted as FBB8 in this study). Following with the concept of HPSFAs, in the present research, a systematic investigation on adding other elements, such as Hf and Zr, and optimizing the Ti content within the alloy system, has been conducted, in order to further improve the creep resistance of the model alloys. Studies include advanced experimental techniques, first-principles calculations on thermodynamic and mechanical properties, and numerical simulations on precipitation hardening, have been integrated and conducted to characterize the complex microstructures and excellent creep resistance of alloys. The experimental techniques include transmission-electron microscopy (TEM), scanning-electron microscopy (SEM), neutron diffraction (ND), and atom-probe tomography (APT), which provide the detailed microstructural information of the model alloys. Systematic tension/compression creep tests have also been conducted in order to verify the creep resistance of the potential alloy compositions. The results show that when replacing Ti with Hf and Zr, it does not form the L21 phase. Instead, the hexagonal Laves phase forms and distributes majorly along the grain boundary, or large segregation within grains. Since the Laves phase does not form parent to the B2-phase precipitates, it cannot bring the strengthening effect of HPSFAs. As a result, the FBB8 + 2 wt. % Hf and FBB8 + 2 wt. % Zr alloys have similar mechanical properties to the original FBB8. The FBB8 + Ti series alloys had also been studied, from the creep tests and microstructural characterizations, the FBB8 + 3.5 wt.% Ti

  2. Fire characteristics associated with firefighter injury on large federal wildland fires.

    Science.gov (United States)

    Britton, Carla; Lynch, Charles F; Torner, James; Peek-Asa, Corinne

    2013-02-01

    Wildland fires present many injury hazards to firefighters. We estimate injury rates and identify fire-related factors associated with injury. Data from the National Interagency Fire Center from 2003 to 2007 provided the number of injuries in which the firefighter could not return to his or her job assignment, person-days worked, and fire characteristics (year, region, season, cause, fuel type, resistance to control, and structures destroyed). We assessed fire-level risk factors of having at least one reported injury using logistic regression. Negative binomial regression was used to examine incidence rate ratios associated with fire-level risk factors. Of 867 fires, 9.5% required the most complex management and 24.7% required the next-highest level of management. Fires most often occurred in the western United States (82.8%), during the summer (69.6%), caused by lightening (54.9%). Timber was the most frequent fuel source (40.2%). Peak incident management level, person-days of exposure, and the fire's resistance to control were significantly related to the odds of a fire having at least one reported injury. However, the most complex fires had a lower injury incidence rate than less complex fires. Although fire complexity and the number of firefighters were associated with the risk for at least one reported injury, the more experienced and specialized firefighting teams had lower injury incidence. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. 46 CFR 108.404 - Selection of fire detection system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Selection of fire detection system. 108.404 Section 108... DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.404 Selection of fire detection system. (a) If a... space. (b) The fire detection system must be designed to minimize false alarms. ...

  4. Computational Design of Creep-Resistant Alloys and Experimental Validation in Ferritic Superalloys

    Energy Technology Data Exchange (ETDEWEB)

    Liaw, Peter

    2014-12-31

    A new class of ferritic superalloys containing B2-type zones inside parent L21-type precipitates in a disordered solid-solution matrix, also known as a hierarchical-precipitate strengthened ferritic alloy (HPSFA), has been developed for high-temperature structural applications in fossil-energy power plants. These alloys were designed by the addition of the Ti element into a previously-studied NiAl-strengthened ferritic alloy (denoted as FBB8 in this study). In the present research, systematic investigations, including advanced experimental techniques, first-principles calculations, and numerical simulations, have been integrated and conducted to characterize the complex microstructures and excellent creep resistance of HPSFAs. The experimental techniques include transmission-electron microscopy, scanningtransmission- electron microscopy, neutron diffraction, and atom-probe tomography, which provide detailed microstructural information of HPSFAs. Systematic tension/compression creep tests revealed that HPSFAs exhibit the superior creep resistance, compared with the FBB8 and conventional ferritic steels (i.e., the creep rates of HPSFAs are about 4 orders of magnitude slower than the FBB8 and conventional ferritic steels.) First-principles calculations include interfacial free energies, anti-phase boundary (APB) free energies, elastic constants, and impurity diffusivities in Fe. Combined with kinetic Monte- Carlo simulations of interdiffusion coefficients, and the integration of computational thermodynamics and kinetics, these calculations provide great understanding of thermodynamic and mechanical properties of HPSFAs. In addition to the systematic experimental approach and first-principles calculations, a series of numerical tools and algorithms, which assist in the optimization of creep properties of ferritic superalloys, are utilized and developed. These numerical simulation results are compared with the available experimental data and previous first

  5. Fire testing for package approval

    International Nuclear Information System (INIS)

    Burgess, M.H.; Fry, C.J.

    1990-01-01

    The IAEA Transport Regulations require packaging systems for radioactive material to survive transport accidents without a significant increase in hazard to members of the public. Tests used to demonstrate this include a fire or 'thermal' test which may be a practical demonstration or based on calculations. Work at Winfrith, involving the development of computer models and pool fire techniques, has given an improved understanding of physical processes. This has been used to improve computer models and pool fire techniques. The paper covers the regulatory requirements for fire testing, the basic physics of fires, practical tests, computer modelling and their applications to package design. We have confidence in our ability to predict temperatures and other conditions in accident situations and can illustrate the important features of fires with experimental evidence. (author)

  6. Co-firing biomass and fossil fuels

    International Nuclear Information System (INIS)

    Junge, D.C.

    1991-01-01

    In June 1989, the Alaska Energy Authority and the University of Alaska Anchorage published a monograph summarizing the technology of co-firing biomass and fossil fuels. The title of the 180 page monograph is 'Use of Mixed Fuels in Direct Combustion Systems'. Highlights from the monograph are presented in this paper with emphasis on the following areas: (1) Equipment design and operational experience co-firing fuels; (2) The impact of co-firing on efficiency; (3) Environmental considerations associated with co-firing; (4) Economic considerations in co-firing; and (5) Decision making criteria for co-firing

  7. Nuclear hazard/fire hazard: an elusive and important linkage

    International Nuclear Information System (INIS)

    Mariani, L.P.

    1977-01-01

    The Brown's Ferry Fire signaled a yellow alert for nuclear safety related fire protection and showed that fire protection engineering must be regarded as a bona fide nuclear discipline. A single-failure design criteria violation resulted in fire damage to plant systems and plant instrumentation. Localized damage lead to significant consequences. Although the linkage between fire and nuclear hazard is termed subtle, effective standards and criteria development must be aimed to future plants. Combined fire protection and nuclear engineering inspections are planned

  8. Thermal resistance matrix representation of thermal effects and thermal design in multi-finger power heterojunction bipolar transistors

    Institute of Scientific and Technical Information of China (English)

    Jin Dong-Yue; Zhang Wan-Rong; Chen Liang; Fu Qiang; Xiao Ying; Wang Ren-Qing; Zhao Xin

    2011-01-01

    The thermal resistance matrix including self-heating thermal resistance and thermal coupling resistance is presented to describe the thermal effects of multi-finger power heterojunction bipolar transistors. The dependence of thermal resistance matrix on finger spacing is also investigated. It is shown that both self-heating thermal resistance and thermal coupling resistance are lowered by increasing the finger spacing, in which the downward dissipated heat path is widened and the heat flow from adjacent fingers is effectively suppressed. The decrease of self-heating thermal resistance and thermal coupling resistance is helpful for improving the thermal stability of power devices. Furthermore, with the aid of the thermal resistance matrix, a 10-finger power heterojunction bipolar transistor (HBT) with non-uniform finger spacing is designed for high thermal stability. The optimized structure can effectively lower the peak temperature while maintaining a uniformity of the temperature profile at various biases and thus the device effectively may operate at a higher power level.

  9. Toward a Theoretical Model of Decision-Making and Resistance to Change among Higher Education Online Course Designers

    Science.gov (United States)

    Dodd, Bucky J.

    2013-01-01

    Online course design is an emerging practice in higher education, yet few theoretical models currently exist to explain or predict how the diffusion of innovations occurs in this space. This study used a descriptive, quantitative survey research design to examine theoretical relationships between decision-making style and resistance to change…

  10. Using resistance and resilience concepts to reduce impacts of annual grasses and altered fire regimes on the sagebrush ecosystem and sage-grouse- A strategic multi-scale approach

    Science.gov (United States)

    Chambers, Jeanne C.; Pyke, David A.; Maestas, Jeremy D.; Boyd, Chad S.; Campbell, Steve; Espinosa, Shawn; Havlina, Doug; Mayer, Kenneth F.; Wuenschel, Amarina

    2014-01-01

    This Report provides a strategic approach for conservation of sagebrush ecosystems and Greater Sage- Grouse (sage-grouse) that focuses specifically on habitat threats caused by invasive annual grasses and altered fire regimes. It uses information on factors that influence (1) sagebrush ecosystem resilience to disturbance and resistance to invasive annual grasses and (2) distribution, relative abundance, and persistence of sage-grouse populations to develop management strategies at both landscape and site scales. A sage-grouse habitat matrix links relative resilience and resistance of sagebrush ecosystems with sage-grouse habitat requirements for landscape cover of sagebrush to help decision makers assess risks and determine appropriate management strategies at landscape scales. Focal areas for management are assessed by overlaying matrix components with sage-grouse Priority Areas for Conservation (PACs), breeding bird densities, and specific habitat threats. Decision tools are discussed for determining the suitability of focal areas for treatment and the most appropriate management treatments.

  11. 46 CFR 108.499 - Fire axes.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire axes. 108.499 Section 108.499 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Miscellaneous Firefighting Equipment § 108.499 Fire axes. Each unit must have at least two...

  12. 36 CFR 2.13 - Fires.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Fires. 2.13 Section 2.13... PROTECTION, PUBLIC USE AND RECREATION § 2.13 Fires. (a) The following are prohibited: (1) Lighting or maintaining a fire, except in designated areas or receptacles and under conditions that may be established by...

  13. Evaluation of performance under fire of compressed earth blocks

    OpenAIRE

    Buson, M.; Lopes, N.; Varum, H.; Sposto, R. M.; Real, P. Vila

    2012-01-01

    In this paper are presented and discussed the main results of fire resistance tests on walls made of soil-cement and Kraftterra compressed earth blocks (CEB). Within this research it was intended to evaluate the fire resistance of walls made with CEB, with and without cellulose pulp incorporation deriving from recycling of cement sacks. Firstly, it is described the Kraftterra production processes and the fire resistance test campaign. Then, the performance of the blocks under anal...

  14. Topological design of all-ceramic dental bridges for enhancing fracture resistance.

    Science.gov (United States)

    Zhang, Zhongpu; Chen, Junning; Li, Eric; Li, Wei; Swain, Michael; Li, Qing

    2016-06-01

    Layered all-ceramic systems have been increasingly adopted in major dental prostheses. However, ceramics are inherently brittle, and they often subject to premature failure under high occlusion forces especially in the posterior region. This study aimed to develop mechanically sound novel topological designs for all-ceramic dental bridges by minimizing the fracture incidence under given loading conditions. A bi-directional evolutionary structural optimization (BESO) technique is implemented within the extended finite element method (XFEM) framework. Extended finite element method allows modeling crack initiation and propagation inside all-ceramic restoration systems. Following this, BESO searches the optimum distribution of two different ceramic materials, namely porcelain and zirconia, for minimizing fracture incidence. A performance index, as per a ratio of peak tensile stress to material strength, is used as a design objective. In this study, the novel XFEM based BESO topology optimization significantly improved structural strength by minimizing performance index for suppressing fracture incidence in the structures. As expected, the fracture resistance and factor of safety of fixed partial dentures structure increased upon redistributing zirconia and porcelain in the optimal topological configuration. Dental CAD/CAM systems and the emerging 3D printing technology were commercially available to facilitate implementation of such a computational design, exhibiting considerable potential for clinical application in the future. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Windscale fire

    International Nuclear Information System (INIS)

    Auxier, J.A.

    1986-01-01

    A graphite fire in the Windscale No. 1 reactor occurred during the period October 8-12, 1957. The Windscale reactors were located on a coastal plain in northwest England and were used to produce plutonium. A great wealth of information was gathered on the causes, handling, decontamination, and environmental effects of reactor accidents. Topics of discussion include: the cause of the fire; handling of the incident; radiation doses to the population; and radiation effects on the population

  16. Design and simulation of resistive SOI CMOS micro-heaters for high temperature gas sensors

    International Nuclear Information System (INIS)

    Iwaki, T; Covington, J A; Udrea, F; Ali, S Z; Guha, P K; Gardner, J W

    2005-01-01

    This paper describes the design of doped single crystal silicon (SCS) microhotplates for gas sensors. Resistive heaters are formed by an n+/p+ implantation into a Silicon-On-Insulator (SOI) wafer with a post-CMOS deep reactive ion etch to remove the silicon substrate. Hence they are fully compatible with CMOS technologies and allows for the integration of associated drive/detection circuitry. 2D electro-thermal models have been constructed and the results of numerical simulations using FEMLAB[reg] are given. Simulations show these micro-hotplates can operate at temperatures of 500 deg. C with a drive voltage of only 5 V and a power consumption of less than 100 mW

  17. Simulation and design of feedback control on resistive wall modes in Keda Torus eXperiment

    International Nuclear Information System (INIS)

    Li, Chenguang; Liu, Wandong; Li, Hong

    2014-01-01

    The feedback control of resistive wall modes (RWMs) in Keda Torus eXperiment (KTX) (Liu et al., Plasma Phys. Controlled Fusion 56, 094009 (2014)) is investigated by simulation. A linear model is built to describe the growth of the unstable modes in the absence of feedback and the resulting mode suppression due to feedback, given the typical reversed field pinch plasma equilibrium. The layout of KTX with two shell structures (the vacuum vessel and the stabilizing shell) is taken into account. The feedback performance is explored both in the scheme of “clean mode control” (Zanca et al., Nucl. Fusion 47, 1425 (2007)) and “raw mode control.” The discrete time control model with specific characteristic times will mimic the real feedback control action and lead to the favored control cycle. Moreover, the conceptual design of feedback control system is also presented, targeting on both RWMs and tearing modes

  18. The Design and Implementation of Tamper Resistance for Mobile Game Service

    Directory of Open Access Journals (Sweden)

    Hang Bae Chang

    2010-01-01

    Full Text Available The commensurate number of the attacks and infringement targeting a vulnerability of the game service has been increasing constantly, due to the dramatic growth and expansion of the impact of the game industry. However, there exist no subsequent researches for the differentiated technology, which is to prevent the reverse function of the game service. Therefore, in this study, we examined the current status of infringement toward online game services which are provided in the market currently and designed the proper technical measures ('Software Tamper Resistance' for a manipulation of the game service which is the most vulnerable part. In detail, we have encrypted an execution file and decrypted it in real time process. After that we implemented antibebugging, disassemble, and antidump technology.

  19. Development of flame retardant, radiation resistant insulating materials

    Energy Technology Data Exchange (ETDEWEB)

    Hagiwara, M.

    1984-01-01

    On the cables used for nuclear power stations, in particular those ranked as IE class, flame retardation test, simulated LOCA environment test, radiation resistance test and so on are imposed. The results of the evaluation of performance by these tests largely depend on the insulating materials mainly made of polymers. Ethylene propylene copolymer rubber has been widely used as cable insulator because of its electrical characteristics, workability, economy and relatively good radiation resistance, but it is combustible, therefore, in the practical use, it is necessary to make it fire resistant. The author et al. have advanced the research on the molecular design of new fire retarding materials, and successfully developed acenaphthylene bromide condensate, which is not only fire resistant but also effective for improving radiation resistance. The condition of flame retardant, radiation resistant auxiliary agents is explained, and there are additive type and reaction type in fire retarding materials. The synthesis of acenaphthylene bromide condensate and its effect of giving flame retardant and radiation resistant properties are reported. The characteristics of the cables insulated with the flame retardant ethylene propylene rubber containing acenaphthylene bromide condensate were tested, and the results are shown. (Kako, I.).

  20. Response of fire detectors to different smokes

    International Nuclear Information System (INIS)

    Bjoerkman, J.; Keski-Rahkonen, O.

    1997-01-01

    The purpose of this work is to characterize the behavior of fire alarm systems based on smoke detectors on smoldering fires especially cable fires in nuclear power plants (NPP). Full-scale fire experiments were carried out in a laboratory designed according to the standard EN54-9. The laboratory was instrumented with additional equipment such as thermocouples and flow meters which are not used in standard fire sensitivity tests. This allows the results to be used as experimental data for validation tasks of numerical fire simulation computerized fluid dynamics (CFD)-codes. The ultimate goal of the research is to model theoretically smoldering and flaming cable fires, their smoke production, transfer of smoke to detectors, as well as the response of detectors and fire alarm systems to potential fires. This would allow the use of numerical fire simulation to predict fire hazards in different fire scenarios found important in PSA (probability safety assessment) of NPPs. This report concentrates on explaining full-scale fire experiments in the smoke sensitivity laboratory and experimental results from fire tests of detectors. Validation tasks with CFD-codes will be first carried out 'blind' without any idea about corresponding experimental results. Accordingly, the experimental results cannot be published in this report. (orig.)

  1. Solution of Fire Protection in Historic Buildings

    Science.gov (United States)

    Iringová, Agnes; Idunk, Róbert

    2016-12-01

    The paper introduces optimization of the functional use of renovated spaces in historic buildings in terms of fire risk. It brings assessment of fire protection in the folk house Habánsky Dvor, situated in the village of Veľké Leváre, whose function was changed into the museum. It goes into static analysis of existing load-bearing structures and assessment of their fire resistance according to Eurocodes.

  2. Conceptual design for muon detectors using resistive plastic tubes. Final technical report

    International Nuclear Information System (INIS)

    Border, P.; Courant, H.; Heller, K.; Jones, A.; Lin, J.; Maxam, D.; Ruddick, K.

    1998-01-01

    Reliable low cost detectors which can be built in quantity require a simple design consisting of as few separate pieces as possible using inexpensive materials. For example, ordinary insulating plastics with good structural strength, such as polyethylene or polystyrene, have about 1/3 the cost of aluminum per unit weight. Since plastic is also about 1/3 the density of aluminum, the material cost for a drift tube would be reduced by an order of magnitude. This substitution of plastic for aluminum alone would save the muon system for the SDC more than $2M. Additional savings of greater magnitude can be expected since an entire drift tube, including a field shaping electrode structure, can be manufactured as a single piece by the technique of co-extrusion. A symmetric design with all walls far from the wire will also eliminate critical tolerances in the relative position of the electrodes with respect to the wire. Furthermore, module assembly and mounting costs will surely be reduced if the muon detectors were light weight and, as far as possible, had the same shape and size. With the 8 cm diameter plastic tube of the design, the electric drift field is nearly uniform as shown. This field is determined by a simple symmetric electrode structure, so that the necessary drift/position relationship can be achieved without precisely controlling the position of the electrode structure with respect to the wire. If the positioning of the electrode structure relative to the wire is not a critical dimension, the structural support for the tube need not be maintained to a high tolerance reducing the cost of the structure. Using a resistive plastic to shape the potential gives a simple electrode structure that will require a minimum number of electronic connections. The basic element of this design is the cylindrical plastic drift tube constructed from co-extruded plastics of different conductivity

  3. Design and implementation of a control system to improve the quality of the combustion gases in the fire-tube boiler of 5 BHP

    Directory of Open Access Journals (Sweden)

    Carlos Alfredo Pérez Albán

    2016-06-01

    Full Text Available The goal of this paper is the design and implementation of a system for controlling the quality of the combustion gases in a fire-tube boiler of 5 BHP. Based on the percentage of O2 present in the combustion gases, measured by a lambda sensor, the percentage of CO2 emitted into the atmosphere is determined. PID proportional control is responsible for the automatic regulation of the entry of air to the boiler by an actuator, according to the percentage of the oxygen concentration in the combustion gases. The control system has an HMI display and a modular PLC. The results achieved ensure pollutant gases emissions within the parameters established by current environmental standards, achieving the required quality of combustion gases and reducing the fuel consumption of the boiler.

  4. Design optimization and sensitivity analysis of a biomass-fired combined cooling, heating and power system with thermal energy storage systems

    International Nuclear Information System (INIS)

    Caliano, Martina; Bianco, Nicola; Graditi, Giorgio; Mongibello, Luigi

    2017-01-01

    Highlights: • A novel operation strategy for biomass-fired combined cooling, heating and power system is presented. • A design optimization of the system is conducted. • The effects of variation of the incentive for the electricity generation are evaluated. • The effects of the variation of the absorption chiller size and the thermal energy storage system one are evaluated. • The inclusion of a cold storage system into the combined cooling, heating and power system is also analyzed. - Abstract: In this work, an operation strategy for a biomass-fired combined cooling, heating and power system, composed of a cogeneration unit, an absorption chiller, and a thermal energy storage system, is formulated in order to satisfy time-varying energy demands of an Italian cluster of residential multi-apartment buildings. This operation strategy is adopted for performing the economical optimization of the design of two of the devices composing the combined cooling, heating and power system, namely the absorption chiller and the storage system. A sensitivity analysis is carried out in order to evaluate the impact of the incentive for the electricity generation on the optimized results, and also to evaluate, separately, the effects of the variation of the absorption chiller size, and the effects of the variation of the thermal energy storage system size on the system performance. In addition, the inclusion into the system of a cold thermal energy storage system is analyzed, as well, assuming different possible values for the cold storage system cost. The results of the sensitivity analysis indicate that the most influencing factors from the economical point of view are represented by the incentive for the electricity generation and the absorption chiller power. Results also show that the combined use of a thermal energy storage and of a cold thermal energy storage during the hot season could represent a viable solution from the economical point of view.

  5. Identifying the location of fire refuges in wet forest ecosystems.

    Science.gov (United States)

    Berry, Laurence E; Driscoll, Don A; Stein, John A; Blanchard, Wade; Banks, Sam C; Bradstock, Ross A; Lindenmayer, David B

    2015-12-01

    The increasing frequency of large, high-severity fires threatens the survival of old-growth specialist fauna in fire-prone forests. Within topographically diverse montane forests, areas that experience less severe or fewer fires compared with those prevailing in the landscape may present unique resource opportunities enabling old-growth specialist fauna to survive. Statistical landscape models that identify the extent and distribution of potential fire refuges may assist land managers to incorporate these areas into relevant biodiversity conservation strategies. We used a case study in an Australian wet montane forest to establish how predictive fire simulation models can be interpreted as management tools to identify potential fire refuges. We examined the relationship between the probability of fire refuge occurrence as predicted by an existing fire refuge model and fire severity experienced during a large wildfire. We also examined the extent to which local fire severity was influenced by fire severity in the surrounding landscape. We used a combination of statistical approaches, including generalized linear modeling, variogram analysis, and receiver operating characteristics and area under the curve analysis (ROC AUC). We found that the amount of unburned habitat and the factors influencing the retention and location of fire refuges varied with fire conditions. Under extreme fire conditions, the distribution of fire refuges was limited to only extremely sheltered, fire-resistant regions of the landscape. During extreme fire conditions, fire severity patterns were largely determined by stochastic factors that could not be predicted by the model. When fire conditions were moderate, physical landscape properties appeared to mediate fire severity distribution. Our study demonstrates that land managers can employ predictive landscape fire models to identify the broader climatic and spatial domain within which fire refuges are likely to be present. It is essential

  6. Fire-safety engineering and performance-based codes

    DEFF Research Database (Denmark)

    Sørensen, Lars Schiøtt

    project administrators, etc. The book deals with the following topics: • Historical presentation on the subject of fire • Legislation and building project administration • European fire standardization • Passive and active fire protection • Performance-based Codes • Fire-safety Engineering • Fundamental......Fire-safety Engineering is written as a textbook for Engineering students at universities and other institutions of higher education that teach in the area of fire. The book can also be used as a work of reference for consulting engineers, Building product manufacturers, contractors, building...... thermodynamics • Heat exchange during the fire process • Skin burns • Burning rate, energy release rate and design fires • Proposal to Risk-based design fires • Proposal to a Fire scale • Material ignition and flame spread • Fire dynamics in buildings • Combustion products and toxic gases • Smoke inhalation...

  7. Advanced turbine systems program conceptual design and product development task 5 -- market study of the gas fired ATS. Topical report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    Solar Turbines Incorporated (Solar), in partnership with the Department of Energy, will develop a family of advanced gas turbine-based power systems (ATS) for widespread commercialization within the domestic and international industrial marketplace, and to the rapidly changing electric power generation industry. The objective of the jointly-funded Program is to introduce an ATS with high efficiency, and markedly reduced emissions levels, in high numbers as rapidly as possible following introduction. This Topical Report is submitted in response to the requirements outlined in Task 5 of the Department of Energy METC Contract on Advanced Combustion Systems, Contract No, DE AC21-93MC30246 (Contract), for a Market Study of the Gas Fired Advanced Turbine System. It presents a market study for the ATS proposed by Solar, and will examine both the economic and siting constraints of the ATS compared with competing systems in the various candidate markets. Also contained within this report is an examination and analysis of Solar`s ATS and its ability to compete in future utility and industrial markets, as well as factors affecting the marketability of the ATS.

  8. Fiscal 1998 achievement report on regional consortium research and development project. Venture business raising type regional consortium - small business creating base type (Development of fire resistant materials for preventing dioxin emissions from waste incinerators and development of fused ash into resources - 2nd year); 1998 nendo gomi shokyaku shisetsu kara no dioxin haishutsu boshiyo taika zairyo no kaihatsu oyobi hai yoyubutsu no shigenka seika hokokusho. 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The above-named studies aim at enhancing the practical application of gasification fusion furnaces designed to burn at high temperatures for the prevention of dioxin emissions. In the basic study for the development of high-temperature corrosion resistant refractories, it is found that cromia, picrochromite, zirconia, and some others are highly resistant to fused slag of refuse and that chromia is the best among them. As for non-chromia based materials, it is found that they turn equivalent in terms of corrosion resistance to chromia based materials when silica based minerals are added to them. In the effort to develop chromia based new fire resistant materials, some which are excellent in corrosion resistance are obtained out of materials based on MgO-Cr{sub 2}O{sub 3} or Al{sub 2}O{sub 3}-Cr{sub 2}O{sub 3}. In the study of developing fused slag into resources, it is learned that there is feasibility of using heat treated mixtures of slag and waste glass as a material for pavement, as a material for ordinary building bricks, and as a substitute of sand for concrete. (NEDO)

  9. Solid waste drum array fire performance

    International Nuclear Information System (INIS)

    Louie, R.L.; Haecker, C.F.; Beitel, J.J.; Gottuck, D.T.; Rhodes, B.T.; Bayier, C.L.

    1995-09-01

    Fire hazards associated with drum storage of radioactively contaminated waste are a major concern in DOE waste storage facilities. This report is the second of two reports on fire testing designed to provide data relative to the propagation of a fire among storage drum arrays. The first report covers testing of individual drums subjected to an initiating fire and the development of the analytical methodology to predict fire propagation among storage drum arrays. This report is the second report, which documents the results of drum array fire tests. The purpose of the array tests was to confirm the analytical methodology developed by Phase I fire testing. These tests provide conclusive evidence that fire will not propagate from drum to drum unless an continuous fuel source other than drum contents is provided

  10. SFPE handbook of fire protection engineering

    CERN Document Server

    Gottuk, Daniel; Jr, John; Harada, Kazunori; Kuligowski, Erica; Puchovsky, Milosh; Torero, Jose´; Jr, John; WIECZOREK, CHRISTOPHER

    2016-01-01

    Revised and significantly expanded, the fifth edition of this classic work offers both new and substantially updated information. As the definitive reference on fire protection engineering, this book provides thorough treatment of the current best practices in fire protection engineering and performance-based fire safety. Over 130 eminent fire engineers and researchers contributed chapters to the book, representing universities and professional organizations around the world. It remains the indispensible source for reliable coverage of fire safety engineering fundamentals, fire dynamics, hazard calculations, fire risk analysis, modeling and more. With seventeen new chapters and over 1,800 figures, the this new edition contains: • Step-by-step equations that explain engineering calculations • Comprehensive revision of the coverage of human behavior in fire, including several new chapters on egress system design, occupant evacuation scenarios, combustion toxicity and data for human behavior analysis • Rev...

  11. Performance-based plastic design of earthquake resistant reinforced concrete moment frames

    Science.gov (United States)

    Liao, Wen-Cheng

    Performance-Based Plastic Design (PBPD) method has been recently developed to achieve enhanced performance of earthquake resistant structures. The design concept uses pre-selected target drift and yield mechanism as performance criteria. The design base shear for selected hazard level is determined by equating the work needed to push the structure monotonically up to the target drift to the corresponding energy demand of an equivalent SDOF oscillator. This study presents development of the PBPD approach as applied to reinforced concrete special moment frame (RC SMF) structures. RC structures present special challenge because of their complex and degrading ("pinched") hysteretic behavior. In order to account for the degrading hysteretic behavior the 1-EMA 440 C2 factor approach was used in the process of determining the design base shear. Four baseline RC SMF (4, 8, 12 and 20-story) as used in the FEMA P695 were selected for this study. Those frames were redesigned by the PBPD approach. The baseline frames and the PBPD frames were subjected to extensive inelastic pushover and time-history analyses. The PBPD frames showed much improved response meeting all desired performance objectives, including the intended yield mechanisms and the target drifts. On the contrary, the baseline frames experienced large story drifts due to flexural yielding of the columns. The work-energy equation to determine design base shear can also be used to estimate seismic demands, called the energy spectrum method. In this approach the skeleton force-displacement (capacity) curve of the structure is converted into energy-displacement plot (Ec) which is superimposed over the corresponding energy demand plot ( Ed) for the specified hazard level to determine the expected peak displacement demands. In summary, this study shows that the PBPD approach can be successfully applied to RC moment frame structures as well, and that the responses of the example moment frames were much improved over those

  12. Active Fire Mapping Program

    Science.gov (United States)

    Active Fire Mapping Program Current Large Incidents (Home) New Large Incidents Fire Detection Maps MODIS Satellite Imagery VIIRS Satellite Imagery Fire Detection GIS Data Fire Data in Google Earth ...

  13. Fire Safety (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Fire Safety KidsHealth / For Parents / Fire Safety What's in ... event of a fire emergency in your home. Fire Prevention Of course, the best way to practice ...

  14. Fire Research Enclosure

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Simulates submarine fires, enclosed aircraft fires, and fires in enclosures at shore facilities .DESCRIPTION: FIRE I is a pressurizable, 324 cu m(11,400 cu...

  15. 46 CFR 108.413 - Fusible element fire detection system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fusible element fire detection system. 108.413 Section... UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.413 Fusible element fire detection system. (a) A fusible element fire detection system may be installed. (b) The arrangements for the system...

  16. Terminology and biology of fire scars in selected central hardwoods

    Science.gov (United States)

    Kevin T. Smith; Elaine Kennedy Sutherland

    2001-01-01

    Dendrochronological analysis of fire scars requires tree survival of fire exposure. Trees survive fire exposure by: (1) avoidance of injury through constitutive protection and (2) induced defense. Induced defenses include (a) compartmentalization processes that resist the spread of injury and infection and (b) closure processes that restore the continuity of the...

  17. Fire safety regulations and licensing

    International Nuclear Information System (INIS)

    Berg, H.P.

    1998-01-01

    Experience of the past tow decades of nuclear power plant operation and results obtained from modern analytical techniques confirm that fires may be a real threat to nuclear safety and should receive adequate attention from the design phase throughout the life of the plant. Fire events, in particular influence significantly plant safety due to the fact that fires have the potential to simultaneously damage components of redundant safety-related equipment. Hence, the importance of fire protection for the overall safety of a nuclear power plant has to be reflected by the fire safety regulations and to be checked during the licensing process of a plant as well as during the continuous supervision of the operating plant

  18. A study for disaster prevention in the case of the underground fire

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bok Youn; Kang, Chang Hee; Jo, Young Do; Lim, Sang Taek [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1997-12-01

    There are three categories of possible disaster or hazard in workings where diesel equipment are operating. 1) Disasters by exhaust pollutants: The equipment specially designed for underground use are strongly recommended. Workings using diesel equipment should be properly ventilated all the time to maintain the gas concentration bellow the permissible level. The fume diluter is recommended as the most practical after treatment device in Korean mines. 2) Underground fire: The main cause of diesel fire is over heated engine and spillage of hydraulic liquid. Therefore, protecting the over heat of engine, using fire resistive hydraulic liquid and high flash point fuel is requested. Fuel and the other oils are recommended to be stored at surface. To protect the smoke return in case of underground fire, the ventilation velocity must be kept more than 1.5m/sec. The fire smoke starts to return on 1.5m/sec and stops to return on 2.0m/sec. The fire smoke flows through upper half of the tunnel and it`s temperature is 10 degrees higher than ventilation air flow. For taking an immediate measure on fire, keeping the updated simulation is essential matter. 3) Other disasters. (author). 9 tabs., 15 figs.

  19. Comparing effects of fire modeling methods on simulated fire patterns and succession: a case study in the Missouri Ozarks

    Science.gov (United States)

    Jian Yang; Hong S. He; Brian R. Sturtevant; Brian R. Miranda; Eric J. Gustafson

    2008-01-01

    We compared four fire spread simulation methods (completely random, dynamic percolation. size-based minimum travel time algorithm. and duration-based minimum travel time algorithm) and two fire occurrence simulation methods (Poisson fire frequency model and hierarchical fire frequency model) using a two-way factorial design. We examined these treatment effects on...

  20. Ecological effects of alternative fuel-reduction treatments: highlights of the National Fire and Fire Surrogate study (FFS)

    Science.gov (United States)

    James D. McIver; Scott L. Stephens; James K. Agee; Jamie Barbour; Ralph E. J. Boerner; Carl B. Edminster; Karen L. Erickson; Kerry L. Farris; Christopher J. Fettig; Carl E. Fiedler; Sally Haase; Stephen C. Hart; Jon E. Keeley; Eric E. Knapp; John F. Lehmkuhl; Jason J. Moghaddas; William Otrosina; Kenneth W. Outcalt; Dylan W. Schwilk; Carl N. Skinner; Thomas A. Waldrop; C. Phillip Weatherspoon; Daniel A. Yaussy; Andrew Youngblood; Steve Zack

    2012-01-01

    The 12-site National Fire and Fire Surrogate study (FFS) was a multivariate experiment that evaluated ecological consequences of alternative fuel-reduction treatments in seasonally dry forests of the US. Each site was a replicated experiment with a common design that compared an un-manipulated control, prescribed fire, mechanical and mechanical + fire treatments....

  1. Fire management of California shrubland landscapes

    Science.gov (United States)

    Keeley, Jon E.

    2002-01-01

    Fire management of California shrublands has been heavily influenced by policies designed for coniferous forests, however, fire suppression has not effectively excluded fire from chaparral and coastal sage scrub landscapes and catastrophic wildfires are not the result of unnatural fuel accumulation. There is no evidence that prescribed burning in these shrublands provides any resource benefit and in some areas may negatively impact shrublands by increasing fire frequency. Therefore, fire hazard reduction is the primary justification for prescription burning, but it is doubtful that rotational burning to create landscape age mosaics is a cost effective method of controlling catastrophic wildfires. There are problems with prescription burning in this crown-fire ecosystem that are not shared by forests with a natural surface-fire regime. Prescription weather conditions preclude burning at rotation intervals sufficient to effect the control of fires ignited under severe weather conditions. Fire management should focus on strategic placement of prescription burns to both insure the most efficient fire hazard reduction and to minimize the amount of landscape exposed to unnaturally high fire frequency. A major contributor to increased fire suppression costs and increased loss of property and lives is the continued urban sprawl into wildlands naturally subjected to high intensity crown fires. Differences in shrubland fire history suggest there may be a need for different fire management tactics between central coastal and southern California. Much less is known about shrubland fire history in the Sierra Nevada foothills and interior North Coast Ranges, and thus it would be prudent to not transfer these ideas too broadly across the range of chaparral until we have a clearer understanding of the extent of regional variation in shrubland fire regimes.

  2. Flux control-based design of furfural-resistance strains of Saccharomyces cerevisiae for lignocellulosic biorefinery.

    Science.gov (United States)

    Unrean, Pornkamol

    2017-04-01

    We have previously developed a dynamic flux balance analysis of Saccharomyces cerevisiae for elucidation of genome-wide flux response to furfural perturbation (Unrean and Franzen, Biotechnol J 10(8):1248-1258, 2015). Herein, the dynamic flux distributions were analyzed by flux control analysis to identify target overexpressed genes for improved yeast robustness against furfural. The flux control coefficient (FCC) identified overexpressing isocitrate dehydrogenase (IDH1), a rate-controlling flux for ethanol fermentation, and dicarboxylate carrier (DIC1), a limiting flux for cell growth, as keys of furfural-resistance phenotype. Consistent with the model prediction, strain characterization showed 1.2- and 2.0-fold improvement in ethanol synthesis and furfural detoxification rates, respectively, by IDH1 overexpressed mutant compared to the control. DIC1 overexpressed mutant grew at 1.3-fold faster and reduced furfural at 1.4-fold faster than the control under the furfural challenge. This study hence demonstrated the FCC-based approach as an effective tool for guiding the design of robust yeast strains.

  3. Design of barrier coatings on kink-resistant peripheral nerve conduits

    Directory of Open Access Journals (Sweden)

    Basak Acan Clements

    2016-02-01

    Full Text Available Here, we report on the design of braided peripheral nerve conduits with barrier coatings. Braiding of extruded polymer fibers generates nerve conduits with excellent mechanical properties, high flexibility, and significant kink-resistance. However, braiding also results in variable levels of porosity in the conduit wall, which can lead to the infiltration of fibrous tissue into the interior of the conduit. This problem can be controlled by the application of secondary barrier coatings. Using a critical size defect in a rat sciatic nerve model, the importance of controlling the porosity of the nerve conduit walls was explored. Braided conduits without barrier coatings allowed cellular infiltration that limited nerve recovery. Several types of secondary barrier coatings were tested in animal studies, including (1 electrospinning a layer of polymer fibers onto the surface of the conduit and (2 coating the conduit with a cross-linked hyaluronic acid-based hydrogel. Sixteen weeks after implantation, hyaluronic acid-coated conduits had higher axonal density, displayed higher muscle weight, and better electrophysiological signal recovery than uncoated conduits or conduits having an electrospun layer of polymer fibers. This study indicates that braiding is a promising method of fabrication to improve the mechanical properties of peripheral nerve conduits and demonstrates the need to control the porosity of the conduit wall to optimize functional nerve recovery.

  4. Simulating wall and corner fire tests on wood products with the OSU room fire model

    Science.gov (United States)

    H. C. Tran

    1994-01-01

    This work demonstrates the complexity of modeling wall and corner fires in a compartment. The model chosen for this purpose is the Ohio State University (OSU) room fire model. This model was designed to simulate fire growth on walls in a compartment and therefore lends itself to direct comparison with standard room test results. The model input were bench-scale data...

  5. A new conceptual cold-end design of boilers for coal-fired power plants with waste heat recovery

    International Nuclear Information System (INIS)

    Yang, Yongping; Xu, Cheng; Xu, Gang; Han, Yu; Fang, Yaxiong; Zhang, Dongke

    2015-01-01

    Highlights: • A new cold-end design of boilers for CFPPs with waste heat recovery is proposed. • Thermodynamic and economic analyses are quantitatively conducted. • Higher energy efficiency improvement and greater economic benefits are achieved. • Lower exergy destruction and better matched energy level are obtained. - Abstract: After conducting an in-depth analysis of the conventional boiler cold-end design for waste heat recovery, this work proposed a new conceptual boiler cold-end design integrated with the steam cycle in a 1000 MW CFPP, in which the preheating of air was divided into high-temperature air preheater (HTAP), main air preheater (MAP) and low-temperature air preheater (LTAP). The HTAP and an economizer were installed in separate flue ducts, and the low temperature economizer (LTE) was situated between the MAP and the LTAP in the main flue duct to heat the condensed water. In the proposed boiler cold-end design, the flue gas waste heat was not only used to heat condensed water, but also to further preheat the combustion air. The air temperature at the air-preheater outlet increases and part of the steam bleeds with high exergy can be saved, resulting in greater energy-savings and better economics. Results showed that, for a typical 1000 MW CFPP in China, using the proposed boiler cold-end design for waste heat recovery could produce 13.3 MW e additional net power output with a heat rate reduction of approximately 112.0 kJ/kW h and could yield a net benefit of up to $85.8 M per year, which is much greater than those of the conventional cases. Exergy destruction is also reduced from 49.9 MW th in the conventional boiler cold-end design to 39.6 MW th in the proposed design

  6. Fire safety assessment of tunnel structures

    DEFF Research Database (Denmark)

    Gkoumas, Konstantinos; Giuliani, Luisa; Petrini, Francesco

    2011-01-01

    .g. structural and non structural, organizational, human behavior). This is even more truth for the fire safety design of such structures. Fire safety in tunnels is challenging because of the particular environment, bearing in mind also that a fire can occur in different phases of the tunnel’s lifecycle. Plans...... for upgrading fire safety provisions and tunnel management are also important for existing tunnels. In this study, following a brief introduction of issues regarding the above mentioned aspects, the structural performance of a steel rib for a tunnel infrastructure subject to fire is assessed by means...

  7. Parametric fuselage design : Integration of mechanics and acoustic & thermal insulation

    NARCIS (Netherlands)

    Krakers, L.A.

    2009-01-01

    Designing a fuselage is a very complex process, which involves many different aspects like strength and stability, fatigue, damage tolerance, fire resistance, thermal and acoustic insulation but also inspection, maintenance, production and repair aspects. It is difficult to include all design

  8. Energy Design Analysis and Evaluation of a Proposed Air Rescue and Fire Fighting Administration Building for Teterboro Airport

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, B.; Pless, S.; Talbert, B.; Deru, M.; Torcellini, P.

    2003-07-01

    A new/proposed building for the Teterboro Airport was selected as a case study for High Performance Building Initiative research efforts. This report documents research-level energy analysis conducted on the Teterboro Airport building during predesign and design phases of the project.

  9. A dynamic model used for controller design of a coal fired once-through boiler-turbine unit

    International Nuclear Information System (INIS)

    Liu, Ji-Zhen; Yan, Shu; Zeng, De-Liang; Hu, Yong; Lv, You

    2015-01-01

    Supercritical OTB (once-through boiler) units with high steam temperature and pressure have been widely used in modern power plants due to their high cycle efficiency and less emissions. To ensure the effective operation of such power generation systems, it is necessary to build a model for the design of the overall control system. There are already detailed models of once-through boilers; however, their complexity prevents them from being applied in the controller design. This study describes a lumped parameter dynamic model that has a relatively low complexity while faithfully capturing the essential overall plant dynamics. The model structure was derived by fundamental physical laws utilizing reasonable simplifications and data analysis to avoid the phase transition position problem. Parameter identification for the model structure was completed using operational data from a 1000 MW ultra-supercritical OTB. The model was determined to be reasonable by comparison tests between computed data and measured data for both steady and dynamic states. The simplified model is verified to have appropriate fidelity in control system design to achieve effective and economic operation of the unit. - Highlights: • A simplified dynamic model of once-through boiler-turbine unit is given. • The essential dynamics of active power and throttle pressure is presented. • The change of phase transition position is avoided in modeling process. • The model has appropriate complexity and fidelity for controller design.

  10. Fire extinguishing device for nuclear power plant

    International Nuclear Information System (INIS)

    Arakawa, Ken

    1990-01-01

    Fire extinguishing pipelines disposed in turbine buildings of low earthquake proof grade and fire extinguishing pipelines disposed in reactor buildings of high earthquakes proof grade have been used in common with each other. Accordingly, if the fire extinguishing device in the turbine buildings designed for low earthquake proof grade are partially destroyed upon occurrence of medium-scale earthquakes, there is a worry that fire extinguishing water can not be supplied to the inside of the reactor buildings. In view of the above, an emergency fire extinguishing water system using a fire extinguishing reservoir at the outdoor of low earthquake proof grade as a feedwater source and suitable to the low earthquake proof grade is disposed in the turbine buildings. Another emergency fire extinguishing water system using an emergency fire extinguishing water reservoir disposed in the reactor buildings as a feedwater source and suitable to the high earthquake proof grade is disposed in the reactor buildings. Then, ordinary fire extinguishing water system and the emergency fire extinguishing water system are connected to each other. Thus, upon occurrence of earthquakes if the function of the ordinary fire extinguishing water system of low earthquake proof grade is lost, fires breaking out in the reactor buildings can rapidly be extinguished. (N.H.)

  11. Thermal characterization of intumescent fire retardant paints

    International Nuclear Information System (INIS)

    Calabrese, L; Bozzoli, F; Rainieri, S; Pagliarini, G; Bochicchio, G; Tessadri, B

    2014-01-01

    Intumescent coatings are now the dominant passive fire protection materials used in industrial and commercial buildings. The coatings, which usually are composed of inorganic components contained in a polymer matrix, are inert at low temperatures and at higher temperatures, they expand and degrade to provide a charred layer of low conductivity materials. The charred layer, which acts as thermal barrier, will prevent heat transfer to underlying substrate. The thermal properties of intumescent paints are often unknown and difficult to be estimated since they vary significantly during the expansion process; for this reason the fire resistance validation of a commercial coatings is based on expensive, large-scale methods where each commercial coating-beam configuration has to be tested one by one. Adopting, instead, approaches based on a thermal modelling of the intumescent paint coating could provide an helpful tool to make easier the test procedure and to support the design of fire resistant structures as well. The present investigation is focused on the assessment of a methodology intended to the restoration of the equivalent thermal conductivity of the intumescent layer produced under the action of a cone calorimetric apparatus. The estimation procedure is based on the inverse heat conduction problem approach, where the temperature values measured at some locations inside the layer during the expansion process are used as input known data. The results point out that the equivalent thermal conductivity reached by the intumescent material at the end of the expansion process significantly depends on the temperature while the initial thickness of the paint does not seem to have much effect

  12. Thermal characterization of intumescent fire retardant paints

    Science.gov (United States)

    Calabrese, L.; Bozzoli, F.; Bochicchio, G.; Tessadri, B.; Rainieri, S.; Pagliarini, G.

    2014-11-01

    Intumescent coatings are now the dominant passive fire protection materials used in industrial and commercial buildings. The coatings, which usually are composed of inorganic components contained in a polymer matrix, are inert at low temperatures and at higher temperatures, they expand and degrade to provide a charred layer of low conductivity materials. The charred layer, which acts as thermal barrier, will prevent heat transfer to underlying substrate. The thermal properties of intumescent paints are often unknown and difficult to be estimated since they vary significantly during the expansion process; for this reason the fire resistance validation of a commercial coatings is based on expensive, large-scale methods where each commercial coating-beam configuration has to be tested one by one. Adopting, instead, approaches based on a thermal modelling of the intumescent paint coating could provide an helpful tool to make easier the test procedure and to support the design of fire resistant structures as well. The present investigation is focused on the assessment of a methodology intended to the restoration of the equivalent thermal conductivity of the intumescent layer produced under the action of a cone calorimetric apparatus. The estimation procedure is based on the inverse heat conduction problem approach, where the temperature values measured at some locations inside the layer during the expansion process are used as input known data. The results point out that the equivalent thermal conductivity reached by the intumescent material at the end of the expansion process significantly depends on the temperature while the initial thickness of the paint does not seem to have much effect.

  13. FIRE-PRAN

    International Nuclear Information System (INIS)

    Waterfall, K.W.

    1991-01-01

    Shell Internationale Petroleum Maatschappij B.V. (SIPM), is a service company in the Royal Dutch/Shell Group of Companies who provides services worldwide (outside of the USA) to Shell Operating Companies. It has defined and recommended for implementation by Shell Companies a policy on safety (Enhanced Safety Management policy) to manage the total safety aspects of all they do, including the design, engineering, installation and operation of their facilities worldwide. This policy affects all activities in such a way as to avoid harm to health of, or injury to employees and others as well as avoiding damage to property. This in turn reflects through specific policies and standards for investment strategy, engineering and operations of facilities. With average Group losses due to major fires and explosion (for each incident over Brit-pounds 100,000) between 1988 and 1990 being of the order of Brit-pounds 28 million, there is an obvious potential to effectively employ fire protection criteria in design. However, Shell need to ensure the cost-effective application of protective measures, but first and foremost it is essential not to jeopardize life or risk damage to the environment. FIRE-PRAN has the possibility to do this efficiently as it is A systematic team approach for identification of all potential fire and explosion hazards and consequences, and a means for developing optimal means of protection for all types of facilities. It should thus be considered as an auditing technique, but one that fits into the overall safe management of activities. This paper discusses the status of development of the FIRE-PRAN technique following its successful application over a number of years to a variety of equipment and installations

  14. A method to design high SNR nanoscale magnetic sensors using an array of tunnelling magneto-resistance (TMR) devices

    International Nuclear Information System (INIS)

    Gomez, P; Litvinov, D; Khizroev, S

    2007-01-01

    This paper presents a systematic method to design and calculate tunnelling magneto-resistance (TMR) sensors with high signal-to-noise ratio (SNR). The sensing module consists of four TMR devices arranged in a Wheatstone-bridge configuration. Closed-form equations were obtained to calculate TMR sensor current, array output voltage, magneto-resistance ratio, overall noise (thermal and shot) and SNR for a given bandwidth. Using this technique we were able to maximize the SNR by tuning the many parameters of the TMR devices. Typical SNR values are in excess of 45 dB

  15. PG BN 1600 sodium fire protection system

    International Nuclear Information System (INIS)

    Bar, J.; Urbancik, L.

    1978-12-01

    A design was developed of a fire protection system for steam generator of a 1600 MW sodium cooled fast reactor (BN-1600). Chemical reactions are described of liquid sodium with atmospheric components and solid materials coming into contact with sodium in its release from the steam generator, and in safeguarding protection against sodium fires. The requirements for the purity of nitrogen as an atmosphere inert to liquid sodium are given. Characteristics and basic parameters are shown of level and spray fires, elementary terms are explained concerning the properties of aerosols formed during fires, the methods and means of release signalling and fire alarm are described as are fire precautions using fire-fighting equipment, modifying the support tank and the cell bottom and building sewage pits. The design of the system comprises an alarm system for liquid sodium using point and line electric contact sensors and flame photometer based aerosol sensors as well as a fire-fighting system based on the system of channelling liquid sodium into emergency discharge tanks filled with an inert gas, a set of fire extinguishers and other fire fighting material, and measures for the elimination of sodium fire consequences. (J.B.)

  16. Testing and design of radon resisting membranes based on the experience from the Czech Republic

    International Nuclear Information System (INIS)

    Jiranek, M.

    2004-01-01

    Testing of barrier properties of insulating materials against radon is usually based on the measurement of the radon diffusion coefficient. Presented report summarizes results of radon diffusion coefficients measurements in more than 120 insulating materials obtained throughout Europe. All measurements were performed by the Czech Technical University, Faculty of Civil Engineering in cooperation with the Radiation Protection Institute. We have found out that great differences exist in diffusion properties, because the diffusion coefficients vary within eight orders from 10 -15 m 2 /s to 10 -8 m 2 /s. For each material category of different chemical composition statistical evaluation of results is presented. Possibilities of usage of the radon diffusion coefficient for the design of radon resisting membranes are discussed. Based on the experience from the Czech Republic the paper is trying to show that controlling applicability of membranes by setting of the upper limit for the radon diffusion coefficient is not a convenient approach. The main reason is that it is almost impossible to choose correctly one limit value for the whole Europe. The second reason is that a great number of common waterproofing materials have their radon diffusion coefficients above the probable limit value. As a consequence of this the protection against radon will be solved preferably by materials with Al foils, which is from the technical point of view meaningless, because membranes with Al foils have very low elongation and therefore they can very easily loose their barrier properties by destroying of the Al foil. The paper will show that it seems to be reasonable to replace strict limits by the real design of the insulation in dependence on particular building and soil characteristics. The design is proposed to be based on the calculation of the insulation thickness according to the formula: d ≥ l.arc sinh ((α 1 .l.λ.C S .(A f + A w ))/C dif .n.V)) (in m), where C S is the third

  17. FIRE - Flyby of Io with Repeat Encounters: A conceptual design for a New Frontiers mission to Io

    Science.gov (United States)

    Suer, Terry-Ann; Padovan, Sebastiano; Whitten, Jennifer L.; Potter, Ross W. K.; Shkolyar, Svetlana; Cable, Morgan; Walker, Catherine; Szalay, Jamey; Parker, Charles; Cumbers, John; Gentry, Diana; Harrison, Tanya; Naidu, Shantanu; Trammell, Harold J.; Reimuller, Jason; Budney, Charles J.; Lowes, Leslie L.

    2017-09-01

    A conceptual design is presented for a low complexity, heritage-based flyby mission to Io, Jupiter's innermost Galilean satellite and the most volcanically active body in the Solar System. The design addresses the 2011 Decadal Survey's recommendation for a New Frontiers class mission to Io and is based upon the result of the June 2012 NASA-JPL Planetary Science Summer School. A science payload is proposed to investigate the link between the structure of Io's interior, its volcanic activity, its surface composition, and its tectonics. A study of Io's atmospheric processes and Io's role in the Jovian magnetosphere is also planned. The instrument suite includes a visible/near-IR imager, a magnetic field and plasma suite, a dust analyzer, and a gimbaled high gain antenna to perform radio science. Payload activity and spacecraft operations would be powered by three Advanced Stirling Radioisotope Generators (ASRG). The primary mission includes 10 flybys with close-encounter altitudes as low as 100 km. The mission risks are mitigated by ensuring that relevant components are radiation tolerant and by using redundancy and flight-proven parts in the design. The spacecraft would be launched on an Atlas V rocket with a delta-v of 1.3 km/s. Three gravity assists (Venus, Earth, Earth) would be used to reach the Jupiter system in a 6-year cruise. The resulting concept demonstrates the rich scientific return of a flyby mission to Io.

  18. Fuel moisture influences on fire-altered carbon in masticated fuels: An experimental study

    Science.gov (United States)

    Nolan W. Brewer; Alistair M.S. Smith; Jeffery A. Hatten; Philip E. Higuera; Andrew T. Hudak; Roger D. Ottmar; Wade T. Tinkham

    2013-01-01

    Biomass burning is a significant contributor to atmospheric carbon emissions but may also provide an avenue in which fire-affected ecosystems can accumulate carbon over time, through the generation of highly resistant fire-altered carbon. Identifying how fuel moisture, and subsequent changes in the fire behavior, relates to the production of fire-altered carbon is...

  19. IPSN's experimental programmes on fires

    International Nuclear Information System (INIS)

    1999-01-01

    Every year fires occur in nuclear installations as they do in any industrial facility. They feed on cables, electrical equipment cabinets, oils, solvents..., they might lead to the degradation of the safety standard of the installation or they might threaten the confinement of radioactive materials. In this document IPSN presents its experimental programmes and its facilities in Saclay and Cadarache designed to study the triggering and the propagation of fires and flames in closed and ventilated premises. (A.C.)

  20. Fire Behavior (FB)

    Science.gov (United States)

    Robert E. Keane

    2006-01-01

    The Fire Behavior (FB) method is used to describe the behavior of the fire and the ambient weather and fuel conditions that influence the fire behavior. Fire behavior methods are not plot based and are collected by fire event and time-date. In general, the fire behavior data are used to interpret the fire effects documented in the plot-level sampling. Unlike the other...