WorldWideScience

Sample records for filling materials medico-legal

  1. Medico-legal aspects of vertical root fractures in root filled teeth

    DEFF Research Database (Denmark)

    Rosen, E; Tsesis, I; Tamse, A

    2012-01-01

    To analyse the medico-legal aspects of vertical root fracture (VRF) following root canal treatment (RCT).......To analyse the medico-legal aspects of vertical root fracture (VRF) following root canal treatment (RCT)....

  2. Medico-legal issues in breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Purushothaman, H.N., E-mail: hema.purushothaman@bartsandthelondon.nhs.uk [Department of Radiology, St Bartholomew' s Hospital, London (United Kingdom); Wilson, R. [Department of Radiology, The Royal Marsden Hospital, Sutton, Surrey (United Kingdom); Michell, M.J. [Department of Radiology, King' s College Hospital, London (United Kingdom)

    2012-07-15

    Aim: To identify medico-legal issues that occur in the diagnosis and radiological management of breast disease and to propose measures to reduce the risk of patient complaints and legal action in breast radiology and diagnosis. Materials and methods: Institutional review board approval was not applicable for this study. A retrospective study was undertaken and records of 120 medico-legal investigations over a 10 year period were examined. The reports were compiled by two consultant breast radiologists. Results: The mean age of the patients represented in this study was 48.3 years. The main complaint in this series was a delay in diagnosis (92%) followed by inappropriate or inadequate treatment (8%). 81% of cases were patients who had presented to the symptomatic clinic. The main presenting symptom was a palpable lump (65%). Substandard care was cited in 49/120 cases (41%). The mean average delay in diagnosis was 15.6 months. Of the cases cited as substandard care, 61% were considered the fault of the radiologist and 14% considered the fault of the breast surgeon. Of the cases where the radiologist was considered to be at fault, microcalcification was the most common mammographic sign to be missed or misinterpreted (12/26 cases, 46%). Conclusion: The most common complaint in this series was delay in diagnosis with microcalcification being the main mammographic sign that was either not seen or misinterpreted by the radiologist. Clear and precise written protocols are recommended for all breast imaging practice to ensure that medico-legal investigations will be greatly reduced.

  3. Medico-legal issues in breast imaging

    International Nuclear Information System (INIS)

    Purushothaman, H.N.; Wilson, R.; Michell, M.J.

    2012-01-01

    Aim: To identify medico-legal issues that occur in the diagnosis and radiological management of breast disease and to propose measures to reduce the risk of patient complaints and legal action in breast radiology and diagnosis. Materials and methods: Institutional review board approval was not applicable for this study. A retrospective study was undertaken and records of 120 medico-legal investigations over a 10 year period were examined. The reports were compiled by two consultant breast radiologists. Results: The mean age of the patients represented in this study was 48.3 years. The main complaint in this series was a delay in diagnosis (92%) followed by inappropriate or inadequate treatment (8%). 81% of cases were patients who had presented to the symptomatic clinic. The main presenting symptom was a palpable lump (65%). Substandard care was cited in 49/120 cases (41%). The mean average delay in diagnosis was 15.6 months. Of the cases cited as substandard care, 61% were considered the fault of the radiologist and 14% considered the fault of the breast surgeon. Of the cases where the radiologist was considered to be at fault, microcalcification was the most common mammographic sign to be missed or misinterpreted (12/26 cases, 46%). Conclusion: The most common complaint in this series was delay in diagnosis with microcalcification being the main mammographic sign that was either not seen or misinterpreted by the radiologist. Clear and precise written protocols are recommended for all breast imaging practice to ensure that medico-legal investigations will be greatly reduced.

  4. Medico-legal autopsies in Denmark

    DEFF Research Database (Denmark)

    Larsen, Sara Tangmose; Lynnerup, Niels

    2011-01-01

    At 2.7% in 1970, the Danish medico-legal autopsy frequency was lower than recent frequencies observed in the Nordic countries (4-24%). The aim of this study was to analyse trends in the number and frequency of Danish medico-legal autopsies.......At 2.7% in 1970, the Danish medico-legal autopsy frequency was lower than recent frequencies observed in the Nordic countries (4-24%). The aim of this study was to analyse trends in the number and frequency of Danish medico-legal autopsies....

  5. Ethical issues in medico-legal exposures

    International Nuclear Information System (INIS)

    O'Reilly, G.; Malone, J. F.

    2008-01-01

    The Medical Exposure Directive (MED) 97/43/Euratom defines medico-legal procedures as 'procedures performed for insurance or legal purposes without a medical indication'. The term 'medico-legal exposures' covers a wide range of possible types of exposures, very different in nature, for which the only feature in common is the fact that the main reason for performing them does not relate directly to the health of the individual being exposed to ionising radiation. The key issue in medico-legal exposures is justification. Balancing the advantages and disadvantages of such exposures is complex because not only can these be difficult to quantify and hence compare, but often the advantage may be to society whereas the disadvantage is usually to an individual. This adds an additional layer of ethical complexity to the problem and one, which requires input from a number of sources beyond the established radiation protection community. Because medico-legal exposures are considered to be medical exposures, they are not subject to dose limits. In medico-legal exposures where the benefit is not necessarily to the individual undergoing the exposure, the question must be asked as to whether or not this is an appropriate framework within which to conduct such exposures. This paper looks at the current situation in Europe, highlighting some of the particular problems that have arisen, and tries to identify the areas, which require further clarification and guidance. (authors)

  6. Radiodermatitis. Etiological and medico-legal considerations

    International Nuclear Information System (INIS)

    Bredard-Usseglio, Catherine.

    1978-04-01

    This study covers 22 radiodermatitis cases recorded in and around Paris and in industry, from January 1st 1967 to mid-1977, by the health insurance treasury of te Paris region. Special attention was paid to the analysis of their frequency, seriousness and causes and of the medico-legal problems involved. According to our observations these accidents mainly affect radiometallographers, crystallographers, people studying materials by X-fluorescence and technicians responsible for maintenance of medical X-ray radiotherapy machines, the activities most prevalent in the industrial use of ionizing radiations. Three main accident factors are observed: imperfections in the protection system and in the maintenance of equipment; carelessness of personnel towards ionizing radiations owing to the apparent absence of immediate effects; lack of information on the danger of ionizing radiations and on the defensive measures necessary. Three means of protection must be developed as a result: wearing of an extra dosimeter on the wrist or finger; permanent information of staff; checks on equipment and constant improvement in the protection of particularly dangerous instruments (gammagraphs). Acute and chronic radiodermatitis are taken in charge as occupational diseases since they appear in table six of these illnesses with a coverage period of 60 days and 10 years. Radiodermatitis patients face the question of professional reclassification, a difficulty all the greater as their qualifications are high. The possibility of paid professional training for occupational disease victims is especially useful when the subjects are still young [fr

  7. Radiographic investigations during medico-legal autopsies

    Energy Technology Data Exchange (ETDEWEB)

    Bratzke, H.; Schneider, V.; Dietz, W.

    1982-04-01

    During the last 13 years (1968-1980), 427 radiographic examinations were carried out during the course of medico-legal autopsies at the Institute of Forensic Medicine at the Free University of Berlin. Important problems were the demonstration of retained foreign bodies resulting from shooting, stabbing or blunt trauma, bone injuries, identification, and the question of life in neonates. An historical survey is given and 12 cases with special forensic problems are illustrated and discussed, and further means of investigations are described.

  8. Awareness of medico-legal issues among medical and dental college health professionals

    Directory of Open Access Journals (Sweden)

    S Senthilkumar

    2013-01-01

    Full Text Available Introduction: The changing doctor-patient relationship and commercialization of modem medical practice has affected the practice of medicine. The fundamental values of medicine insist that the doctors should be aware about the various medico-legal issues which help in proper recording of medical management details. Aim: To evaluate the knowledge on Medico-legal Issues among Medical and Dental College Health Professionals of Meenakshi University (MAHER, Tamilnadu. Materials & Method: A cross-sectional survey was conducted among health professionals of Meenakshi University (MAHER, Tamilnadu. A total o f320 health professionals (163 medical and 157 dental participated in the study. A structured, closed ended, self-administered questionnaire was used for collection of data. Chi-square test was used to compare the awareness of medico-legal issues between medical and dental health professionals. Results: Among the 320 health professionals, 87.4% of medical and 76.1% of dental professionals were aware about the informed consent, 18.8% of medical and 5.7% of dental professionals had awareness about COPRA and only 14.3% of medical and 7.6% of dental professionals had awareness regarding the Medico-legal programs/courses. Conclusions: The results illustrated that the participants had little awareness on medico-legal issues. Hence there is an urgent need to update the understanding of these issues to be on a legally safer side.

  9. Radiographic investigations during medico-legal autopsies

    International Nuclear Information System (INIS)

    Bratzke, H.; Schneider, V.; Dietz, W.

    1982-01-01

    During the last 13 years (1968-1980), 427 radiographic examinations were carried out during the course of medico-legal autopsies at the Institute of Forensic Medicine at the Free University of Berlin. Important problems were the demonstration of retained foreign bodies resulting from shooting, stabbing or blunt trauma, bone injuries, identification, and the question of life in neonates. An historical survey is given and 12 cases with special forensic problems are illustrated and discussed, and further means of investigations are described. (orig.) [de

  10. Forensic medicine experts' opinion on medico-legal autopsies in hospital deaths: a questionnaire survey.

    Science.gov (United States)

    D'Souza, Deepak Herald; Pant, Sadip; Menezes, Ritesh George

    2013-10-01

    Medico-legal autopsy is conducted routinely in some countries and selectively in others in hospital deaths. This study was conducted to evaluate the views of the forensic medicine experts regarding this matter. A questionnaire pro forma was sent to sixty-five forensic medicine experts practicing in different medical institutions all around India. Designations and experiences of the participants were noted by requests in the same questionnaire. Their specific experience in conducting medico-legal autopsy in hospital deaths was also requested for. Responses were charted in frequency distribution tables and analyzed using SPSS, version 17.0. One-third of the participants felt that a medico-legal autopsy was necessary in all the hospital death cases as defined in the present study. Ten percent of the participants opined that a medico-legal autopsy was unnecessary in hospital deaths. The majority of the experts mentioned finding the cause of death, followed by finding the manner of death and collecting the evidentiary materials, as the reasons for medico-legal autopsy in hospital deaths. Twenty percent of the participants felt that internal findings at autopsy poorly matched with the case records. All the experts agreed that external autopsy findings matched with the hospital case records. Nearly two-third of the participants felt that it was difficult in some cases to interpret the autopsy findings without case records from the hospital where the deceased was treated. Our findings suggest that the exercise of carrying out medico-legal autopsy routinely in every hospital death as evident in the Indian framework is often unnecessary as per the experts' opinion. Autopsy findings in hospital deaths often correlate with hospital case records.

  11. Part 1: Medico-legal documentation South African Police Services ...

    African Journals Online (AJOL)

    Valid medico-legal consent differs from medical consent. Knowledge of legislation pertaining to child pornography and the practical and ethical aspects of photography is also necessary. Inappropriate completion of medico-legal documentation may necessitate the practitioner having to explain the documentation to make it ...

  12. Medico-legal documentation South African Police Services forms

    African Journals Online (AJOL)

    information to the court and to be an educator. S Afr Fam ... Keywords: forensic medicine, medico-legal, legal documentation, assault, sexual assault, under the influence. Abstract .... Documentation in the absence of a South African Police.

  13. Aspects of dento/medico-legal report writing.

    Science.gov (United States)

    Wood, Geoff D

    2014-03-01

    This paper offers some guidance on aspects of dento/medico-legal report writing, citing anonymized examples from the author's caseload for clarification of the points made, and also serves to illustrate that sometimes not everything is as straightforward as it may initially appear. It provides reference to the current Civil Procedure Rules in England and Wales and its relevance in report writing. To provide guidance on aspects of dento/medico-legal report writing.

  14. [Medical data security in medico-legal opinioning].

    Science.gov (United States)

    Susło, Robert; Swiatek, Barbara

    2005-01-01

    Medical data security can be approached in medico-legal opinioning in three main situations: security of medical data, on which the opinion should be based, opinioning itself and whether the medical data security was properly ensured and ensuring medical data security during medico-legal opinion giving. The importance of medical data security, during collecting, processing and storing, as well in medical as in legal institutions, is of major importance for the possibility of providing a proper medico-legal opinion. Theoretically speeking, it is possible to give a proper medico-legal opinion using incorrect data, but the possibility is low. When the expert is given improper, unreadable, incomplete or even bogus in part or in the whole medical data it is extremely possible, that he fails in giving his opinion. The term "medical data" was defined and subsequently there was a brief review of medical data storing methods made and specific threats bound with them, based on modern literature. The authors also pointed out possible methods of preventing the threats. They listed Polish as well as international regulations and laws concerning the problem, accenting the importance of preserving medical data for the purposes of medico-legal opinioning.

  15. [Relevant factors in medico-legal prognosis of whiplash injury].

    Science.gov (United States)

    Pujol, Amadeo; Puig, Luisa; Mansilla, Joaquina; Idiaquez, Itziar

    2003-07-12

    Whiplash injury (WI) is commonly evaluated in medico-legal practice. With the aim of knowing the determining factors of WI's medico-legal prognosis, a prospective and observational study was carried out. One hundred and twenty consecutive patients who were clinically observed and evaluated in the Medico-Legal Clinic of Barcelona were studied. Socio-demographic, clinical, radiographic and evolutive factors were analyzed. We included 120 patients with a mean age of 35.6 (14) years (range, 4-74), with a homogeneous male/female distribution. An earlier cervical pathology was detected in 10% of patients; none of them had previous psychiatric pathology. 95% corresponded to road-traffic accident cases and there were 5 aggression cases. Over 50% of cases involved a rear-end collision. All patients had neck pain, almost 25% had headache and 13% had paresthesia. According to the Whiplash Association Disorders clinical classification, distribution in grades (G) was: G I 51%, G II 32% and G III 17%. Patients reported recovery within a mean time of 71.6 (46) days (range, 4-244), with 51,2 (45) no working days (range, 0-180 days). The 52% of the patients rest with complains. According to the recovery time, the following medico-legal prognostic factors were identified: age (p legal prognostic factors were age, being females, severity of initial clinical symptoms, previous cervical pathology and abnormal cervical MRI/CT.

  16. Medico Legal Autopsies In Aba, Nigeria | Offiah | Abia State ...

    African Journals Online (AJOL)

    To determine the pattern of medico legal autopsies performed between January 2001 to December 2005 so as to highlight any differences or similarities to the observation of workers in other parts of the country and/or world. A hospital based retrospective analysis of coroner's autopsies in Abia State University Teaching ...

  17. Medico-legal documentation of rape or sexual assault: are ...

    African Journals Online (AJOL)

    L Fouché

    Background: Following upon two-year internship, community-service doctors make mistakes when they deal with evidence of medico-legal examinations in various settings. These mistakes .... the participants were doing/had done their community service were obtained. Age and gender distribution. The average age of the ...

  18. Medico-legal litigation: Balancing spiralling costs with fair ...

    African Journals Online (AJOL)

    2015-05-02

    May 2, 2015 ... 8, No. 1 SAJBL. Ames Dhai. Editor amaboo.dhai@wits.ac.za. A Medico Legal Summit was convened by the National. Minister of Health, Dr Aaron Motsoaledi, on 9 and 10 ... of preventable harm at healthcare facilities when managing patients there. Patient safety is a component of good quality healthcare.

  19. Ethical and medico-legal aspects of dementia | Potocnik ...

    African Journals Online (AJOL)

    Ethical and medico-legal aspects of dementia. FCV Potocnik. Abstract. No Abstract. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL ...

  20. Medico legal and de ontological features of breast diagnosis

    International Nuclear Information System (INIS)

    Lopez, J. A.; Lopez, M. C.

    2001-01-01

    A medical and legal review of the literature in regards to the medico legal and de ontological features involved in Imaging Diagnosis of the breast was performed in order to elaborate a series of preventive measures to prevent or reduce the demands on the radiologist. Basically, the contents of the Spanish Medical De ontology Code as well the rules and laws in force in our country have been considered, both from the medical professional point of view as well as from that of the law professional. As a result of the review carried out, a series of preventive measures aimed at reducing the incidence of possible lawsuits against the radiologist who works in breast imaging diagnosis are proposed. The radiologist is regularly involved in lawsuits, especially related with the delay in the diagnosis of breast cancer. In the United States of America and Italy. he(she is the professional who receives the greatest number of lawsuits, being ahead of the gynecologist. The radiologist occupies and important place in the diagnosis of breast cancer, which converts him/her into the object of possible lawsuits. Within these, deadly in the diagnosis of cancer caused by several situations are included: these being, principally, non-detection by mammography, not using the complementary studies and not carrying out an integrated reading of the triad or binomial diagnosis. In some cases, these situations are favored by lack of experience (incompetence) of the radiologists as well as by lack of information from the patient. In order to avoid possible lawsuits, the most important preventive measures are: a) inform the patient; b) be competent in the material: c) follow an action Protocol according to the l ex artis: d) in the case of being staff, comply with the guidelines of Quality Control: e) elaborate clear and concise written reports, maintaining, if relevant, the limitations of the procedures used and suggestions for the professional clinician. (Author) 27 refs

  1. The medico-legal investigation of the El Aqsah Intifada.

    Science.gov (United States)

    Hiss, Jehuda; Freund, Maya; Motro, Uzi; Kahana, Tzipi

    2002-07-01

    The majority (n = 445) of the Israeli and Palestinian fatal victims of the El Aqsah Intifada was examined at the National Center of Forensic Medicine in Tel Aviv. Analysis of the trauma sustained and the anthropologic profile of both the victims and the perpetrators elucidates the trends and contrasts them with the phenomenon in the past. The purpose of the forensic investigation of mass casualty incidents is manifold: establishing the minimal number of individuals involved, identifying the victims and perpetrators, collecting material evidence, and determining the modus operandi. The postmortem examination includes external description of the bodies and their injuries, photo-documentation, and sampling of tissues. Radiography, dental examination, and a ten-print card of each cadaver are also recorded. The modus operandi of the current Intifada is somewhat different from that of the previous wave of terrorism and includes more road shootings and vehicular terrorism. In addition, three suicide bombers who detonated explosive devices within crowded areas were young women, and the age of the perpetrators has increased from up to 35 years to individuals as old as 47, thus greatly enlarging the potential number of suicide terrorists. Virologic and biologic tests have been introduced to examine the tissues of the suicide bombers since they are possible sources of contagion to the wounded victims. The results of the medico-legal investigation of victims and perpetrators of terrorism enable us to establish the modus operandi and the profile of potential perpetrators, which can help in the prevention of similar attacks. Documentation of the different types of injuries in fatal victims of explosion and shooting contributes to improving the awareness of the medical staff treating the wounded of similar attacks. Further investigation into the reliability of virologic and biologic tests conducted on postmortem tissue is recommended.

  2. Imaging of body packing: errors and medico-legal issues.

    Science.gov (United States)

    Reginelli, Alfonso; Russo, Anna; Urraro, Fabrizio; Maresca, Duilia; Martiniello, Ciro; D'Andrea, Alfredo; Brunese, Luca; Pinto, Antonio

    2015-10-01

    Body packing is the ingestion or insertion in the human body of packed illicit substances. Over the last 20 years, drug smuggling has increased global and new means of transport of narcotics have emerged. Among these, the most frequent one is the gastrointestinal tract: from mouth to anus, vagina, and ears. Cocaine is one of the most traded drugs, followed by heroin. Condoms, latex gloves, and balloons are typically used as drug packets for retention in the body. There are different radiologic modalities to detect illicit drugs in body packing: Plain radiography, computed tomography (CT), ultrasound, and magnetic resonance. Current protocols recommend the use of radiography to confirm packet retention and, in case of doubt, the use of abdominal CT scan with reduced mAs. In case of packet rupture, catastrophic effects can occur. Management of patients carrying packets of drugs is a recurrent medico-legal problem. To improve diagnostic accuracy and prevent hazardous complications, radiologists and emergency physicians should be familiar with radiologic features of body packing. The radiologist plays both a social and a medico-legal role in their assessment, and it should not be limited only to the identification of the packages but must also provide accurate information about their number and their exact location. In this review, we focus on diagnostic errors and medico-legal issues related to the radiological assessment of body packers.

  3. Ethics and medico legal aspects of "Not for Resuscitation"

    Directory of Open Access Journals (Sweden)

    Naveen Sulakshan Salins

    2010-01-01

    Full Text Available Not for resuscitation in India still remains an abstract concept with no clear guidelines or legal frame work. Cardiopulmonary resuscitation is a complex medical intervention which is often used inappropriately in hospitalized patients and usually guided by medical decision making rather than patient-directed choices. Patient autonomy still remains a weak concept and relatives are expected to make this big decision in a short time and at a time of great emotional distress. This article outlines concepts around ethics and medico legal aspects of not for resuscitation, especially in Indian setting.

  4. Medico legal investigations into sudden sniffing deaths linked with trichloroethylene.

    Science.gov (United States)

    Da Broi, Ugo; Colatutto, Antonio; Sala, Pierguido; Desinan, Lorenzo

    2015-08-01

    Sudden deaths attributed to sniffing trichloroethylene are caused by the abuse of this solvent which produces pleasant inebriating effects with rapid dissipation. In the event of repeated cycles of inhalation, a dangerous and uncontrolled systemic accumulation of trichloroethylene may occur, followed by central nervous system depression, coma and lethal cardiorespiratory arrest. Sometimes death occurs outside the hospital environment, without medical intervention or witnesses and without specific necroscopic signs. Medico legal investigations into sudden sniffing deaths associated with trichloroethylene demand careful analysis of the death scene and related circumstances, a detailed understanding of the deceased's medical history and background of substance abuse and an accurate evaluation of all autopsy and laboratory data, with close cooperation between the judiciary, coroners and toxicologists. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  5. Necessity of including medico-legal autopsy data in epidemiological surveys of individuals with major trauma.

    Science.gov (United States)

    Bagher, A; Wingren, C J; Ottosson, A; Andersson, L; Wangefjord, S; Acosta, S

    2015-08-01

    It is rare that epidemiological surveys of patients with major trauma include both those admitted to the emergency department and those sent for medico-legal autopsy. The main aim of the present population-based study of major trauma was to examine the importance of medico-legal autopsy data. A new injury severity score (NISS)>15 or lethal outcome was used as criteria for major trauma and to identify patients at the emergency, anaesthesiology and forensic departments and/or being within the jurisdiction of the Malmö police authority and subjected to a medico-legal autopsy between 2011 and 2013. According to Swedish legislation all trauma related deaths should be reported to the police who refer these cases for medico-legal autopsy. Among the 174 individuals included, 92 (53%) died and 81 (47%) underwent medico-legal autopsy. One hundred twenty-six patients were primarily admitted to hospital and 48 died before admission to hospital and were sent directly for medico-legal autopsy. Forty-four in-hospital deaths occurred, of whom 33 (75%) were sent to medico-legal autopsy. In those sent directly to the department of forensic medicine the proportion of accidents was lower (pautopsies among trauma-related deaths at hospital were high age (pautopsy according to legislation, but did not. The high proportion of positive toxicological findings among fatalities examined at medico-legal autopsy implies that toxicology screening should be routine in major trauma patients, in order to improve treatment and prevention. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Medico-legal aspects of altered sensation following endodontic treatment: a retrospective case series

    DEFF Research Database (Denmark)

    Givol, Navot; Rosen, Eyal; Bjørndal, Lars

    2011-01-01

    The objective of this study was to analyze cases of liability claims related to persistent altered sensation following endodontic treatments so as to characterize the medico-legal aspects of this complication.......The objective of this study was to analyze cases of liability claims related to persistent altered sensation following endodontic treatments so as to characterize the medico-legal aspects of this complication....

  7. Preventing medico-legal issues in clinical practice

    Directory of Open Access Journals (Sweden)

    Bevinahalli N Raveesh

    2016-01-01

    Full Text Available The medical profession is considered to be one of the noblest professions in the world. The practice of medicine is capable of rendering noble service to humanity provided due care, sincerity, efficiency, and professional skill is observed by the doctors. However, today, the patient–doctor relationship has almost diminished its fiduciary character and has become more formal and structured. Doctors are no longer regarded as infallible and beyond questioning. Corporatization of health care has made it like any other business, and the medical profession is increasingly being guided by the profit motive rather than that of service. On the other hand, a well-publicized malpractice case can ruin the doctor's career and practice. The law, like medicine, is an inexact science. One cannot predict with certainty an outcome of cases many a time. It depends on the particular facts and circumstances of the case, and also the personal notions of the judge concerned who is hearing the case. The axiom “you learn from your mistakes” is too little honored in healthcare. The best way to handle medico-legal issues is by preventing them, and this article tries to enumerate the preventive measures in safeguarding the doctor against negligence suit.

  8. Application of X-rays to dental age estimation in medico-legal practice

    Directory of Open Access Journals (Sweden)

    Dorota Lorkiewicz-Muszyńska

    2015-05-01

    Full Text Available Aim of the study: The paper addresses the use of dental age assessment methods based on radiographs in medico-legal practice. Different cases of practical application of the methods are presented including identification of human remains, dental age assessment in a living person and one archaeological case. Material and methods : The study material consisted of cases involving dental age assessment performed in the Department of Forensic Medicine, Poznan University of Medical Sciences in Poznan. Depending on the preliminary assessment of age, the Liversidge or the Kvaal et al. methods were applied. Dental age was estimated on the basis of available pantomograms. In the case of the living person, it was a radiograph supplied for expert evaluation. In the other cases, dental computed tomography was performed. Results : Dental age was successfully estimated in all of the cases. Various methods based on the analysis of X-ray images were applied. Dental age was shown to be correlated with skeletal age. Conclusions : The methods based on radiographs were demonstrated to be useful, and the results they yield are fully correlated with results of anthropological analyses.

  9. A guide to medico-legal photography for personal injury claims.

    Science.gov (United States)

    Bryson, D

    1994-01-01

    Clinical photographs are in essence medico-legal records but when instructions are given to take photographs for litigation the requirement is for a more specialized approach than when producing a clinical record for the notes. There are special considerations when providing a medico-legal photographic service, from clients' instructions, preparations before photography, and the photography itself to presenting the photographs and handling the administration. As photographs are taken in support of claims for compensation for personal injury many of them can have far greater impact, financially and psychologically, on the client than clinical photographs. Inadequate coverage could be construed as professional negligence.

  10. Documentation of torture victims, assessment of the start procedure for medico-legal documentation.

    Science.gov (United States)

    Mandel, Lene; Worm, Lise

    2007-01-01

    A Pilot Study was performed at the Rehabilitation and Research Centre for Torture Victims (RCT) in Copenhagen in order to explore the possibilities for adding a medico-legal documentation component to the rehabilitation of torture victims already taking place. It describes the process and results on implementing medico-legal documentation in a rehabilitative setting. A modified version of the Guidelines in the Istanbul Protocol was developed on the basis of the review of literature and current practices described in "Documentation of torture victims, implementation of medico-legal protocols". The modified guidelines were tested on five clients. The aim was twofold: 1) To assess the client's attitude towards the idea of adding a documentation component to the rehabilitation process and: 2) To assess the practical circumstances of implementing the Istanbul Protocol in the everyday life of a rehabilitation centre. Results show that all five clients were positive towards the project and found comfort in being able to contribute to the fight against impunity. Also, the Pilot Study demonstrated that a large part of the medico-legal documentation was already obtained in the rehabilitation process. It was however not accessible due to lack of systematization and a data registering system. There are thus important synergies in collecting data for rehabilitation and documentation but a joint database system is necessary to realize these synergies.

  11. HIV/AIDS and mental illness: ethical and medico-legal issues for ...

    African Journals Online (AJOL)

    QuickSilver

    Keywords: HIV/AIDS, Mental health, Ethical, Medico - legal. S Afr Psychiatry Rev 2003 ... Implementation of the Mental Health Care Act of 2002will entail a shift in attitudes .... (Act 17 of 2002). 13 Gauteng Health Department; Environmental and Occupational. Health and Safety Directorate: Memorandum: 7 April 2000. Guide-.

  12. Mob justice as an emerging medico-legal, social and public health ...

    African Journals Online (AJOL)

    Background: Mob-justice poses a medico-legal, social and public health problem in most developing countries including Tanzania and has shown to have negative effects on social and health of the country, communities, and families. This study was conducted to analyze the mob-justice situation in north-western Tanzania ...

  13. The clinical management of diabetic foot in the elderly and medico-legal implications.

    Science.gov (United States)

    Terranova, Claudio; Bruttocao, Andrea

    2013-10-01

    Diabetic foot is a complex and challenging pathological state, characterized by high complexity of management, morbidity and mortality. The elderly present peculiar problems which interfere on one hand with the patient's compliance and on the other with their diagnostic-therapeutic management. Difficult clinical management may result in medico-legal problems, with criminal and civil consequences. In this context, the authors present a review of the literature, analysing aspects concerning the diagnosis and treatment of diabetic foot in the elderly which may turn out to be a source of professional responsibility. Analysis of these aspects provides an opportunity to discuss elements important not only for clinicians and medical workers but also experts (judges, lawyers, medico-legal experts) who must evaluate hypotheses of professional responsibility concerning diabetic foot in the elderly.

  14. Awareness about medico legal aspects and Consumer Protection Act among dentists.

    Science.gov (United States)

    Radhika, T; Nadeem, J; Arthi, R; Nithya, S

    2017-07-01

    The practice of medicine in India has undergone considerable change affecting delivery of health in both positive and negative directions. As a result, there was a growing feeling that medical treatment should be made accountable and this led to doctors and dentists becoming subject to the process of law. Patients have become more aware of their right to compensation and as a consequence doctors and dentists should be knowledgeable about the laws that govern them. To assess the awareness about Medico legal aspects and Consumer Protection Act [CPA] among Dental professionals. A self-structured validated questionnaire comprising of 20 questions related to medico legal aspects and CPA was designed. A total of 450 dental professionals were surveyed from 4 prime dental institutions in Chennai, India. Of the 450 professionals that were surveyed 150 were MDS faculty, 150 were BDS faculty and 150 were PG students. The data was subjected to SPSS, version 16 and statistically analysed using Chi square test and Fisher's exact test. A- p value less than 0.05 was considered to be statistically significant. BDS faculty, MDS faculty and PG students were found to possess similar level of understanding and there was no significant difference between the groups. Knowledge was found to be equal between male and female dentists. The young practitioners were found to be more informed about CPA than the senior practitioners. It was found that most of the participants were aware of relevant Medico legal aspects, but were less aware of CPA. This study emphasises the need for education relevant to Medico legal aspects and CPA for dental professionals.

  15. Traumatic spinal cord injuries – epidemiologic and medico-legal issues

    OpenAIRE

    Hanganu Bianca; Velnic Andreea Alexandra; Petre-Ciudin Valentin; Manoilescu Irina; Ioan Beatrice Gabriela

    2017-01-01

    Spinal cord injuries represent a special category of injuries in traumatic pathology, with high morbidity and mortality, which justify their analysis with the aim to identify useful aspects in order to prevent and treat them. We therefore performed a retrospective study on 426 cases in order to analyze epidemiology and medico-legal issues related to spinal cord injuries. The studied items regarded socio-demographic aspects (gender, age, home region), type of lesions (vertebral, spinal cord, a...

  16. Sexual violence legislation in sub-Saharan Africa: the need for strengthened medico-legal linkages.

    Science.gov (United States)

    Kilonzo, Nduku; Ndung'u, Njoki; Nthamburi, Nerida; Ajema, Caroline; Taegtmeyer, Miriam; Theobald, Sally; Tolhurst, Rachel

    2009-11-01

    Six sub-Saharan African countries currently have laws on sexual violence, including Kenya, and eight others have provisions on sexual violence in other legislation. Effective legislation requires functioning medico-legal linkages to enable both justice to be done in cases of sexual violence and the provision of health services for survivors of sexual violence. The health sector also needs to provide post-rape care services and collect and deliver evidence to the criminal justice system. This paper reviews existing data on sexual violence in sub-Saharan Africa, and summarises the content of sexual violence legislation in the region and the strengths and weaknesses of existing medico-legal linkages, using Kenya as a case study. Many sub-Saharan African countries do not yet have comprehensive post-rape care services, nor substantial co-ordination between HIV and sexual and reproductive health services, the legal and judicial systems, and sexual violence legislation. These need to be integrated by cross-referrals, using standardised referral guidelines and pathways, treatment protocols, and medico-legal procedures. Common training approaches and harmonised information across sectors, and common indicators, would facilitate government accountability. Joint and collaborative planning and working at country level, through sharing of information and data between the different systems remain key to achieving this.

  17. Iatrogenic splenic injury: review of the literature and medico-legal issues

    Directory of Open Access Journals (Sweden)

    Feola Alessandro

    2016-01-01

    Full Text Available Iatrogenic splenic injury is a recognized complication in abdominal surgery. The aim of this paper is to understand the medico-legal issues of iatrogenic splenic injuries. We performed a literature review on PubMed and Scopus using iatrogenic splenic or spleen injury and iatrogenic splenic rupture as keywords. Iatrogenic splenic injury cases were identified. Most cases were related to colonoscopy, but we also identified cases related to upper gastrointestinal procedures, colonic surgery, ERCP, left nephrectomy and/or adrenalectomy, percutaneous nephrolithotomy, vascular operations involving the abdominal aorta, gynecological operation, left lung biopsy, chest drain, very rarely spinal surgery and even cardiopulmonary resuscitation. There are several surgical procedures that can lead to a splenic injury. However, from a medico-legal point of view, it is important to assess whether the cause can be attributed to a technical error of the operator rather than being an unpredictable and unpreventable complication. It is important for the medico-legal expert to have great knowledge on iatrogenic splenic injuries because it is important to evaluate every step of the first procedure performed, how a splenic injury is produced, and whether the correct treatment for the splenic injury was administered in a judgment.

  18. Medico-legal perspectives on sudden cardiac death in young athletes.

    Science.gov (United States)

    Oliva, Antonio; Grassi, Vincenzo M; Campuzano, Oscar; Brion, Maria; Arena, Vincenzo; Partemi, Sara; Coll, Monica; Pascali, Vincenzo L; Brugada, Josep; Carracedo, Angel; Brugada, Ramon

    2017-03-01

    Sudden cardiac death (SCD) in a young athlete represents a dramatic event, and an increasing number of medico-legal cases have addressed this topic. In addition to representing an ethical and medico-legal responsibility, prevention of SCD is directly correlated with accurate eligibility/disqualification decisions, with an inappropriate pronouncement in either direction potentially leading to legal controversy. This review summarizes the common causes of SCD in young athletes, divided into structural (hypertrophic cardiomyopathy, arrhythmogenic cardiomyopathy, congenital coronary artery anomalies, etc.), electrical (Brugada, congenital LQT, Wolf-Parkinson-White syndrome, etc.), and acquired cardiac abnormalities (myocarditis, etc.). In addition, the roles of hereditary cardiac anomalies in SCD in athletes and the effects of a positive result on them and their families are discussed. The medico-legal relevance of pre-participation screening is analyzed, and recommendations from the American Heart Association and European Society of Cardiology are compared. Finally, the main issues concerning the differentiation between physiologic cardiac adaptation in athletes and pathologic findings and, thereby, definition of the so-called gray zone, which is based on exact knowledge of the mechanism of cardiac remodeling including structural or functional adaptions, will be addressed.

  19. Coronary atherosclerosis in medico-legal autopsy cases

    Directory of Open Access Journals (Sweden)

    VN Prasad

    2014-09-01

    Full Text Available Background: Coronary atherosclerosis is the major cause of death worldwide. Lifestyle and habits are the major contributory factor in the development of coronary atherosclerosis. Materials and Methods: This is an autopsy-based study in which 45 autopsy cases were randomly selected for study. Proximal one third of all three epicardial coronary arteries (LAD, LCX and RCA were dissected out for study and serial sections were made and stained with H&E method and under the light microscope. Atherosclerosis was graded according to American heart association classification. The risk factors (cigarette smoking, hypertension, diabetes, alcohol consumption, age, sex were also correlated with the grade of atherosclerosis. Results: Seventy-Eight percent of American Heart Association classification grade V lesions were seen in > 70 yrs of age. Almost all cases of > 70 yrs of age had American Heart Association classification grade > IV lesions. Out of all grade IV lesions, 88.9% was seen in male while only 11.1% in female. Similarly out of all grade V lesions, 77.8% was seen in male while 22.2% in female. LAD showed maximum involvement by higher grade lesion, followed by LCX and RCA. American Heart Association classification grade > IV in LAD, LCX and RCA was seen in 25(55.6%, 5(11.1%, and 3(6.7% cases respectively. Conclusion: Higher grade lesion occurs in advancing age. Various cardiovascular risk factors were significantly associated with higher grade of lesions. The multiple risk factors had a synergistic effect on the progression of coronary atherosclerosis. DOI: http://dx.doi.org/10.3126/jpn.v4i8.11492 Journal of Pathology of Nepal; Vol.4,No8(2014 607-611

  20. Forensic Odontology: A Boon to Community in Medico-legal Affairs

    Directory of Open Access Journals (Sweden)

    Ramasamy Chidambaram

    2016-03-01

    Full Text Available Forensic odontology is a sub-discipline of dental science which involves the relationship between dentistry and the law. The specialty of forensic odontology is applied in radiographic investigation, human bite marks analysis, anthropologic examination and during mass disasters. Besides the fact that radiographs require pretentious laboratory, it is still claimed to be a facile, rapid, non-invasive method of age identification in the deceased. The budding DNA technology has conquered the traditional procedures and currently being contemplated as chief investigating tool in revealing the hidden mysteries of victims and suspects, especially in hopeless circumstances. Forensic odontology has played a chief role in solving cold cases and proved to be strong evidence in the court of law. Systematic collection of dental records and preservation of the same would marshal the legal officials in identification of the deceased. To serve the forensic operation and legal authorities, dental professionals need to be familiar with the basics of forensic odontology, which would create a consciousness to preserve the dental data. The aim of this paper is to emphasize the vital applications of forensic odontology in medico-legal issues. Conjointly the recent advancements applied in forensic human identification have been updated. Keywords: bite marks; dental records; forensic identification; mass disaster; medico-legal issues. | PubMed

  1. Remaking the medico-legal scene: a social history of the late-Victorian coroner in Oxford.

    Science.gov (United States)

    Hurren, Elizabeth T

    2010-04-01

    There have been wide-ranging debates about medicine and the law encapsulated in the figure of the coroner in Victorian England. Recently the historical literature on coroners has been enriched by macro-studies. Despite this important research, the social lives of coroners and their daily interactions remain relatively neglected in standard historical accounts. This article redresses that issue by examining the working life of the coroner for Oxford during the late-Victorian era. Edward Law Hussey kept very detailed records of his time in office as coroner. New research material makes it feasible to trace his professional background, from doctor of the sick poor, to hospital house surgeon and then busy coroner. His career trajectory, personal interactions, and professional disputes, provide an important historical prism illuminating contemporary debates that occupied coroners in their working lives. Hussey tried to improve his medico-legal reach and the public image of his coroner's office by reducing infanticide rates, converting a public mortuary, and acquiring a proper coroner's court. His campaigns had limited success because the social scene in which he worked was complicated by the dominance of health and welfare agencies that resented his role as an expanding arm of the Victorian information state.

  2. Clinical photography in dermatology: ethical and medico-legal considerations in the age of digital and smartphone technology.

    Science.gov (United States)

    Kunde, Lauren; McMeniman, Erin; Parker, Malcolm

    2013-08-01

    Clinical photography has long been an important aspect in the management of dermatological pathology and has many applications in contemporary dermatology practice. With the continuous evolution of digital and smartphone technology, clinicians must maintain ethical and medico-legal standards. This article reviews how dermatology trainees are utilising this technology in their clinical practice and what procedures they follow when taking photos of patients. We review the ethical and legal considerations of clinical photography in dermatology and present a hypothetical medico-legal scenario. Dermatology registrars were surveyed on their use of personal smartphones and digital equipment for photographing patients in their clinical practice. Numerous medico-legal providers were approached to provide medico-legal advice about a hypothetical scenario. We found that the use of these technologies is prevalent among dermatology registrars and all respondents reported regular use. Clinicians should routinely obtain and document adequate patient consent in relation to clinical photography, utilise strict privacy settings on smartphones and other digital devices and ensure that the images are stored on these devices for minimal periods. Express consent documentation in the clinical file puts the clinician in a more defensible position if a complaint is made to the medical board or privacy commissioner. © 2013 The Authors. Australasian Journal of Dermatology © 2013 The Australasian College of Dermatologists.

  3. Back to the Future - Part 1. The medico-legal autopsy from ancient civilization to the post-genomic era.

    Science.gov (United States)

    Cecchetto, Giovanni; Bajanowski, Thomas; Cecchi, Rossana; Favretto, Donata; Grabherr, Silke; Ishikawa, Takaki; Kondo, Toshikazu; Montisci, Massimo; Pfeiffer, Heidi; Bonati, Maurizio Rippa; Shokry, Dina; Vennemann, Marielle; Ferrara, Santo Davide

    2017-07-01

    Part 1 of the review "Back to the Future" examines the historical evolution of the medico-legal autopsy and microscopy techniques, from Ancient Civilization to the Post-Genomic Era. In the section focusing on "The Past", the study of historical sources concerning the origins and development of the medico-legal autopsy, from the Bronze Age until the Middle Ages, shows how, as early as 2000 BC, the performance of autopsies for medico-legal purposes was a known and widespread practice in some ancient civilizations in Egypt, the Far East and later in Europe. In the section focusing on "The Present", the improvement of autopsy techniques by Friedrich Albert Zenker and Rudolf Virchow and the contemporary development of optical microscopy techniques for forensic purposes during the 19th and 20th centuries are reported, emphasizing, the regulation of medico-legal autopsies in diverse nations around the world and the publication of international guidelines or best practices elaborated by International Scientific Societies. Finally, in "The Future" section, innovative robotized and advanced microscopy systems and techniques, including their possible use in the bio-medicolegal field, are reported, which should lead to the improvement and standardization of the autopsy methodology, thereby achieving a more precise identification of natural and traumatic pathologies.

  4. Ireland and medical research with minors: some medico-legal aspects.

    Science.gov (United States)

    Sheikh, Asim A

    2008-07-01

    The practice of medical research with minors in Ireland consist of practices pertaining to therapeutic and non-therapeutic medical research. Clinical trials (a category of therapeutic research), is governed by legislation. However, any other therapeutic research (non-clinical trials research) and non-therapeutic research, e.g. observational medical research such as a longitudinal study of children or non-therapeutic research such as blood sample collection for analysis of cause of disease, are unregulated by legislation. This, article will outline and describe some of the medico-legal issues involved in both types of research and will comment on matters such as what national law exists, how the directive on good clinical practice has been implemented, what guidelines, if any, exist.

  5. [Prevention of the post-surgical insatisfactions and possible medico-legal complications].

    Science.gov (United States)

    Flageul, G; Pessis, R

    2017-10-01

    The purpose of this work is to better understand the reasons for post-surgical instability and what makes up the bed of medico-legal complications. Beyond technical competence, it is essential to observe a very high degree of rigor in listening to the real motivations in order to give the most accurate possible surgical indications and in particular to know to detect and never to operate certain patients who, whatever we do, will always be dissatisfied. The quality of information is one of the essential elements of prevention: information is part of the care and there is no therapeutic success without a successful relationship between a caregiver and a carereceiver. Before the surgery, it is essential to pre-establish written proof of the proper delivery of the information by signing a receipt and an informed consent document. However, the information does not stop at the time of the operative gesture and it is necessary to be able to provide complete and timely information about any post-surgical complications. Furthermore, aesthetic medicine is well understood and rigorously implemented, contributes to the prevention of surgical and medico-legal complications, reducing the heaviness of certain surgical gestures. The question of e-reputation should in no way be neglected. From this point of view, prevention consists in controlling as much as possible the Internet environment. Indeed, where, in the past, in the presence of a dissatisfied patient awaited us, the fear of word-of-mouth or trial is added to the risk of harm E-reputation whose implications can be very damaging. At a time when the intensive use of the Internet allows anyone to get out of anonymity, we must also control these tools at the risk of sacrificing our expertise at the coronation of amateurs. Copyright © 2017. Published by Elsevier Masson SAS.

  6. Radiopacity of root filling materials

    International Nuclear Information System (INIS)

    Beyer-Olsen, E.M.

    1983-01-01

    A method for measuring the radiopacity of root filling materials is described. Direct measurements were made of the optic density values of the materials in comparison with a standard curve relating optic density to the thickness of an aluminium step wedge exposed simultaneously. By proper selection of film and conditions for exposure and development, it was possible to obtain a near-linear standard curve which added to the safety and reproducibility of the method. The technique of radiographic assessment was modified from clinical procedures in evaluating the obturation in radiographs, and it was aimed at detecting slits or voids between the dental wall and the filling material. This radiographic assessment of potensial leakage was compared with actual in vitro lekage of dye (basic fuchsin) into the roots of filled teeth. The result of the investigation show that root filling materials display a very wide range of radiopacity, from less than 3 mm to more than 12 mm of aluminium. It also seem that tooth roots that appear to be well obturated by radiographic evaluation, stand a good chance of beeing resistant to leakage in vitro, and that the type of filling material rather than its radiographic appearance, determines the susceptibility of the filled tooth to leakage in vitro. As an appendix the report contains a survey of radiopaque additives in root filling materials

  7. Traumatic spinal cord injuries – epidemiologic and medico-legal issues

    Directory of Open Access Journals (Sweden)

    Hanganu Bianca

    2017-12-01

    Full Text Available Spinal cord injuries represent a special category of injuries in traumatic pathology, with high morbidity and mortality, which justify their analysis with the aim to identify useful aspects in order to prevent and treat them. We therefore performed a retrospective study on 426 cases in order to analyze epidemiology and medico-legal issues related to spinal cord injuries. The studied items regarded socio-demographic aspects (gender, age, home region, type of lesions (vertebral, spinal cord, association with other trauma, circumstances leading to trauma (cause of the injury, season, data regarding hospitalization (medical condition at the hospital admission, number of days of hospitalization, clinical diagnosis, imaging exploration level and data resulting from autopsy (diagnosis, toxicological examination. Most of our results are consistent with literature data, except for some epidemiological items, which might be explained with cultural differences, life style and inhomogeneous population. Based on our results, the general conclusion is the need for prevention campaigns, focusing on road traffic accidents and falls (especially in elderly as the main causes of spinal cord injuries.

  8. Removal of root filling materials.

    LENUS (Irish Health Repository)

    Duncan, H.F. Chong, B.S.

    2011-05-01

    Safe, successful and effective removal of root filling materials is an integral component of non-surgical root canal re-treatment. Access to the root canal system must be achieved in order to negotiate to the canal terminus so that deficiencies in the original treatment can be rectified. Since a range of materials have been advocated for filling root canals, different techniques are required for their removal. The management of commonly encountered root filling materials during non-surgical re-treatment, including the clinical procedures necessary for removal and the associated risks, are reviewed. As gutta-percha is the most widely used and accepted root filling material, there is a greater emphasis on its removal in this review.

  9. Medico-legal findings, legal case progression, and outcomes in South African rape cases: retrospective review.

    Directory of Open Access Journals (Sweden)

    Rachel Jewkes

    2009-10-01

    Full Text Available BACKGROUND: Health services for victims of rape are recognised as a particularly neglected area of the health sector internationally. Efforts to strengthen these services need to be guided by clinical research. Expert medical evidence is widely used in rape cases, but its contribution to the progress of legal cases is unclear. Only three studies have found an association between documented bodily injuries and convictions in rape cases. This article aims to describe the processing of rape cases by South African police and courts, and the association between documented injuries and DNA and case progression through the criminal justice system. METHODS AND FINDINGS: We analysed a provincially representative sample of 2,068 attempted and completed rape cases reported to 70 randomly selected Gauteng province police stations in 2003. Data sheets were completed from the police dockets and available medical examination forms were copied. 1,547 cases of rape had medical examinations and available forms and were analysed, which was at least 85% of the proportion of the sample having a medical examination. We present logistic regression models of the association between whether a trial started and whether the accused was found guilty and the medico-legal findings for adult and child rapes. Half the suspects were arrested (n = 771, 14% (209 of cases went to trial, and in 3% (31 of adults and 7% (44 of children there was a conviction. A report on DNA was available in 1.4% (22 of cases, but the presence or absence of injuries were documented in all cases. Documented injuries were not associated with arrest, but they were associated with children's cases (but not adult's going to trial (adjusted odds ratio [AOR] for having genital and nongenital injuries 5.83, 95% confidence interval [CI] 1.87-18.13, p = 0.003. In adult cases a conviction was more likely if there were documented injuries, whether nongenital injuries alone AOR 6.25 (95% CI 1.14-34.3, p = 0

  10. Considerations on the medico-legal compensation for stochastic effects induced by the exposure to ionizing radiations in working environment

    International Nuclear Information System (INIS)

    Lafontaine, M.

    1988-01-01

    A better detection of stochastic diseases induced by the exposure to ionizing radiations and the establishment of causative correlation are presently reasons to justify new medico-legal approaches. The right to reparation for workers suffering from diseases which may have been caused by occupational exposure to ionizing radiations in Belgium, is covered by the law on occupational diseases and by the legislation on industrial accidents. However, some difficulties persist, concerning the right for compensation, consisting in the very short delay for prescription, the existence of an administrative list of diseases eligible for compensation and in the burden of proof to establish an obvious etiological relation. (Author)

  11. Some medical and biological reasons of drunkenness and alcoholism and feature of their medico-legal establishment

    Directory of Open Access Journals (Sweden)

    Г. А. Білецька

    2014-12-01

    Full Text Available The article is sanctified to some вiomedical questions of reasons of drunkenness and alcoholism, and also features of their establishment in practice of medico-legal expert in the process of examining and dead body of living man. Study of constitutional and individual features of organism of man, terms of stay and reception of алкогоя help more exactly to diagnose the state of alcoholic intoxication, that is reflected in the conclusion of expert and can be proof on criminal and civil cases.

  12. Using medico-legal data to investigate fatal older road user crash circumstances and risk factors.

    Science.gov (United States)

    Koppel, Sjaan; Bugeja, Lyndal; Smith, Daisy; Lamb, Ashne; Dwyer, Jeremy; Fitzharris, Michael; Newstead, Stuart; D'Elia, Angelo; Charlton, Judith

    2018-02-17

    This study used medico-legal data to investigate fatal older road user (ORU, aged 65 years and older) crash circumstances and risk factors relating to 4 key components of the Safe System approach (e.g., roads and roadsides, vehicles, road users, and speeds) to identify areas of priority for targeted prevention activity. The Coroners' Court of Victoria's (CCOV) Surveillance Database was searched to identify and describe the frequency and rate per 100,000 population of fatal ORU crashes in the Australian state of Victoria for 2013-2014. Information relating to the deceased ORU, crash characteristics and circumstances, and risk factors was extracted and analyzed. One hundred and thirty-eight unintentional fatal ORU crashes were identified in the CCOV Surveillance Database. Of these fatal ORU crashes, most involved older drivers (44%), followed by older pedestrians (32%), older passengers (17%), older pedal cyclists (4%), older motorcyclists (1%), and older mobility scooter users (1%). The average annual rate of fatal ORU crashes per 100,000 population was 8.1 (95% confidence interval [CI], 6.0-10.2). In terms of the crash characteristics and circumstances, most fatal ORU crashes involved a counterpart (98%), of which the majority were passenger cars (50%) or fixed/stationary objects (25%), including trees (46%) or embankments (23%). In addition, most fatal ORU crashes occurred close to home (73%), on-road (87%), on roads that were paved (94%), on roads with light traffic volume (37%), and during low-risk conditions: between 12 p.m. and 6 p.m. (44%), on weekdays (80%), during daylight (75%), and under dry/clear conditions (81%). Road user (RU) error was identified by the police and/or the coroner for the majority of fatal crashes (55%), with a significant proportion of deceased ORUs deemed to have failed to yield (54%) or misjudged (41%). RU error was the most significant factor identified in fatal ORU crashes, which suggests that there is a limited capacity of the

  13. Analysis of the origin and importance of acetone and isopropanol levels in the blood of the deceased for medico-legal testimony.

    Science.gov (United States)

    Borowska-Solonynko, A; Siwińska-Ziółkowska, A; Piotrkowicz, M; Wysmołek, M; Demkow, M

    2014-01-01

    The aim of the study was to analyze the incidence of acetone and isopropanol in the blood of the deceased, and to assess cases in which the compounds have been detected with a focus on their origin and usefulness for medico-legal testimony. The study material consisted of results of tests detecting ethyl alcohol and reports of autopsies performed at the Department of Forensic Medicine, Medical University of Warsaw, from January 2008 to April 2009 - a total of 2,475 cases. The test group proper (group B) comprised only those cases in which acetone was detected in blood, either with or without isopropanol [n = 202 (8.2%)]. The blood levels of isopropanol varied depending on the cause of death. The need for differentiating the origin of isopropanol in the case of its presence in the blood of the deceased was pointed out. The results of the present study show that the differentiation should be based on the isopropanol and acetone concentration ratio, as isopropanol concentration alone is not sufficient for preparing expert opinions. Even high concentrations of isopropanol, when accompanied by even higher concentrations of acetone, imply that isopropanol could have been formed as a result of acetone transformations. Isopropanol concentrations exceeding acetone levels strongly point to the exogenous origin of isopropanol, particularly when high levels of ethanol are concurrently detected.

  14. Drug-related deaths with evidences of body packing: Two case reports and medico-legal issues.

    Science.gov (United States)

    Cappelletti, Simone; Aromatario, Mariarosaria; Bottoni, Edoardo; Fiore, Paola Antonella; Straccamore, Marco; Umani Ronchi, Federica; De Mari, Guido Maria; Ciallella, Costantino

    2016-05-01

    Body packing is a general term used to indicate the internal transportation of drug packages, mainly cocaine, heroin, amphetamines, and methamphetamine, within the gastrointestinal tract. We described two cases of accidental drug intoxication, observed over the last year period, with evidence of intracorporeal drug concealment. The first case concerned a body packer transporting 69 drug packages of heroin adulterated with piracetam. The second body packer transported 16 drug packages of cocaine adulterated with levamisole. For both cases, forensic examination and toxicological analysis of drug packages and biological samples were carried out. Authors also wants to highlight the main medico-legal issues that commonly arise in cases of suspected or ascertained body packers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. An audit of the toxicology findings in 555 medico-legal autopsies finds manner of death changed in 5 cases.

    Science.gov (United States)

    Langlois, Neil E I; Gilbert, John D; Heath, Karen J; Winskog, Calle; Kostakis, Chris

    2013-03-01

    An audit of toxicological analysis in Coronial autopsies performed at Forensic Science South Australia was conducted on the cases of three pathologists. Toxicological analysis had been performed in 555 (68 %) from a total of 815 autopsies. It was found that the proffered manner of death was changed from the provisional report (provided immediately after the post-mortem examination) in five cases (just under 1 %) as a consequence of the toxicological findings. This is a limited study as it is retrospective, not all cases had toxicological analysis and the findings are constrained by the range of the substances that could be detected. Nonetheless, the audit supports the application of toxicological analysis in medico-legal death investigation and suggests that an inclusive policy should be adopted.

  16. Guidelines examination of victims of sexual assault harmonization of forensic and medico-legal examination of persons.

    Science.gov (United States)

    Ludes, B; Geraut, A; Väli, M; Cusack, D; Ferrara, D; Keller, E; Mangin, P; Vieira, D N

    2018-02-21

    Sexual assault is a complex situation with medical, psychological, and legal aspects. Forensic experts play a major role in terms of forensic and gynecological medical examination and evidence collection in order to maintain the chain of custody. Victims should be examined by a specially trained medico-legal examiner in order to avoid multiple examinations in the surroundings that do not meet minimum health standards. The evolution and treatment of sexual assault victims are time-intensive and should optimally be provided by a team that includes a forensic medical doctor. These guidelines will be of interest to forensic medical doctors who will have responsibility for the examination and assessment of victims of sexual violence and can be used as a day-to-day service document and/or a guide to develop health service for victims of sexual violence.

  17. The implementation of medical monitoring programs following potentially hazardous exposures: a medico-legal perspective.

    Science.gov (United States)

    Vearrier, David; Greenberg, Michael I

    2017-11-01

    approach is inconsistent with the targeted approach advocated by the Agency for Toxic Substances and Disease Registry and the United States Preventive Services Task Force and the bulk of the peer-reviewed medical literature. Medical monitoring in legal contexts: Numerous medical monitoring actions have been litigated. Legal rationales for allowing medical monitoring claims often incorporate some of the scientific criteria for the appropriateness of monitoring programs. In the majority of cases in which plaintiffs were awarded medical monitoring relief, plaintiffs were required to demonstrate both that the condition for which medical monitoring was sought could be detected early, and that early detection and treatment will improve morbidity and mortality. However, the treatment of medical monitoring claims varies significantly depending upon jurisdiction. Examples of large-scale, comprehensive medical monitoring programs: Large-scale, comprehensive medical monitoring programs have been implemented, such as the Fernald Medical Monitoring Program and the World Trade Center Health Program, both of which exceeded the scope of medical monitoring typically recommended in the peer-reviewed medical literature and the courts. The Fernald program sought to prevent death and disability due to non-exposure-related conditions in a manner similar to general preventive medicine. The World Trade Center Health Program provides comprehensive medical care for World Trade Center responders and may be viewed as a large-scale, federally--funded research effort, which distinguishes it from medical monitoring in a medico-legal context. Synthesis of public health approaches to medical monitoring: Medical monitoring may be indicated following a hazardous exposure in limited circumstances. General causation for a specific adverse health effect must be either established by scientific consensus through a formal causal analysis using a framework such as the Bradford-Hill criteria. The exposure must be

  18. Microhardness of bulk-fill composite materials

    OpenAIRE

    Kelić, Katarina; Matić, Sanja; Marović, Danijela; Klarić, Eva; Tarle, Zrinka

    2016-01-01

    The aim of the study was to determine microhardness of high- and low-viscosity bulk-fill composite resins and compare it with conventional composite materials. Four materials of high-viscosity were tested, including three bulk-fills: QuiXfi l (QF), x-tra fil (XTF) and Tetric EvoCeram Bulk Fill (TEBCF), while nanohybrid composite GrandioSO (GSO) served as control. The other four were low-viscosity composites, three bulk-fill materials: Smart Dentin Replacement (SDR), Venus Bulk Fill (VBF) and ...

  19. Padova Charter on personal injury and damage under civil-tort law : Medico-legal guidelines on methods of ascertainment and criteria of evaluation.

    Science.gov (United States)

    Ferrara, Santo Davide; Baccino, Eric; Boscolo-Berto, Rafael; Comandè, Giovanni; Domenici, Ranieri; Hernandez-Cueto, Claudio; Gulmen, Mete Korkut; Mendelson, George; Montisci, Massimo; Norelli, Gian Aristide; Pinchi, Vilma; Ranavaya, Mohammed; Shokry, Dina A; Sterzik, Vera; Vermylen, Yvo; Vieira, Duarte Nuno; Viel, Guido; Zoja, Riccardo

    2016-01-01

    Compensation for personal damage, defined as any pecuniary or non-pecuniary loss causally related to a personal injury under civil-tort law, is strictly based on the local jurisdiction and therefore varies significantly across the world. This manuscript presents the first "International Guidelines on Medico-Legal Methods of Ascertainment and Criteria of Evaluation of Personal Injury and Damage under Civil-Tort Law". This consensus document, which includes a step-by-step illustrated explanation of flow charts articulated in eight sequential steps and a comprehensive description of the ascertainment methodology and the criteria of evaluation, has been developed by an International Working Group composed of juridical and medico-legal experts and adopted as Guidelines by the International Academy of Legal Medicine (IALM).

  20. A clinical analysis of 500 medico-legal claims evaluating the causes and assessing the potential benefit of alternative dispute resolution.

    Science.gov (United States)

    B-Lynch, C; Coker, A; Dua, J A

    1996-12-01

    1. To evaluate the common causes of medico-legal dispute in obstetrics and gynaecology. 2. To assess the potential benefit of early alternative dispute resolution. A prospective analysis of over 500 cases submitted from over 100 solicitors between 1984 and 1994 for medical expert opinion on potential medico-legal claims. Five hundred consecutive cases that met the inclusion criteria: 488 from the United Kingdom and 12 from abroad (Hong Kong, Republic of Ireland). The main principles underlining medico-legal disputes and causes of such claims. Analysis of 500 claims show 46% were misguided allegations, 19% incompetent care, 12% error of judgement, 9% lack of expertise, 7% failure of communication, 6% poor supervision and 1% inadequate staffing. Of the misguided allegations 119/225 cases (59%) were obstetric and 111/275 (40%) cases were gynaecological. The most common cause of obstetric dispute was "cerebral palsy' (22%), while the commonest cause of gynaecological dispute was failed sterilisation (19%). Settled claims were under-reported by solicitors. Because of the high percentage (46%) of misguided allegations, an alternative course of dispute resolution must be a realistic way forward. This course of action, combined with improved communication, could result in a major reduction in the costs of potential medical litigation. Early alternative dispute resolution should be considered in an attempt to reduce the escalating quantum of damages and costs. We recommend recruiting independent, experienced and unbiased consultants in active practice within the appropriate specialty to review such cases at the level of hospital complaints management as an in house review procedure, particularly for small and moderate-sized claims, as a means whereby doctors can retain control of medico-legal disputes, in contrast to control by the legal profession.

  1. [Alcohol and work: ethical-deontological and medico-legal remark upon the recent set of rules].

    Science.gov (United States)

    Chiaravalli, M; Guzzetti, Laura; Tavani, M

    2007-01-01

    The Disposition of the Permanent Conference for the relation among the State, the Regions and the Autonomous Provinces of Trento and Bolzano, published in Gazzetta Ufficiale n. 75 on the 30th March 2006 the list of high-risk occupations under the influence of alcohol, activating de facto a previous law (Legge n. 125, 3017 march 2001, "Legge quadro in materia di alcol e di problemi alcolcorrelati"). We here present some ethical-deontological and medical-juridical profiles on the contents of this law and some consideration about its application. Particular attention is dedicated to deontological aspects about industrial safety rules and to medico-legal aspects about occupation under the influence of alcohol, with references to complex relations among worker's discretion right, employer's right to the protection of his own interests and qualified doctor's (or someone to him comparable) right to the respect for the deontological code, with regard to benefit recipient information before the medical treatment. Authors'purpose is to evidence critical points and interpretative ambiguities of a regulation lacking in its practical applications, to provide further proposals of consideration, available to revalue a thematic rich in questions and with a significant social impact.

  2. The necessity of repeated assessment of imaging studies contained in medical records in medico-legal opinions

    Directory of Open Access Journals (Sweden)

    Aleksandra Borowska-Solonynko

    2014-12-01

    Full Text Available The paper presents two case reports of living victims, in which imaging studies of the chest conducted at a medical facility were an essential part of the medico-legal opinion. The first case was that of a young male hospitalized due to CT evidence of bilateral rib fractions, who claimed to have been assaulted by police officers. The other case was that of a six week old baby hospitalized due to chest X-ray evidence of right hand side rib fractions. The chest X-ray was performed due to one bruise found on the baby’s forehead and two small bruises on the back, which gave rise to suspicions of child abuse. In both cases, expert witnesses in radiology definitively excluded the presence of any fractures. These cases indicate that a new assessment of imaging studies contained in medical records is needed. Expert opinions based solely on the description of imaging studies may result in grave consequences.

  3. European Council of Legal Medicine (ECLM) principles for on-site forensic and medico-legal scene and corpse investigation.

    Science.gov (United States)

    Cusack, D; Ferrara, S D; Keller, E; Ludes, B; Mangin, P; Väli, M; Vieira, N

    2017-07-01

    Forensic medical practitioners need to define the general principles governing procedures to be used for the on-site examination of a body where the death has occurred in unnatural, violent or suspicious circumstances. These principles should be followed whenever a medical expert is required to perform an on-site corpse inspection and should be utilised as a set of general guidelines to be adapted to the specific situation in hand and interpreted using common sense and scientific knowledge of the relevant procedures and facts of the case. The aim of these principles is to ensure that forensic evidence at the scene of a death is properly observed and assessed and all necessary relevant evidence gathered in order to ensure that a comprehensive report is available to the judicial authority (investigating judge or coroner) in the justice system. The on-site corpse inspection by a forensic practitioner is a mandatory and essential stage of the forensic and medico-legal autopsy, as it may provide important information for subsequent investigation stages.

  4. A Preliminary Analysis of Insects of Medico-legal Importance in Curitiba, State of Paraná

    Directory of Open Access Journals (Sweden)

    Mauricio Osvaldo Moura

    1997-03-01

    Full Text Available A survey of the carrion fauna was made at two sites in Curitiba, State of Paraná, with the objective of describing the insects associated with carrion and setting up a preliminary data-base for medico-legal purposes in south Brazil. Vertebrate exclusion experiments were carried out in each season between 1994 and 1995 with a 250 g laboratory-bred rat (Rattus norvegicus. Five stages of decomposition were identified: fresh, bloated, decaying, dry and adipocere-like. Some species showed seasonal and site preference and so could be used to identify the probable place and season where death took place. Sarconesia chlorogaster (Diptera, Calliphoridae was restricted to an open field site and to cooler months. Hemilucilia semidiaphana (Diptera, Calliphoridae and Pattonella resona (Diptera, Sarcophagidae were restricted to the forest site and warmer months. Phaenicia eximia (Diptera, Calliphoridae and Oxyletrum discicolle (Coleoptera, Silphidae were present at both sites throughout the year and could be useful for population level analysis. Dissochaetus murray (Coleoptera, Cholevidae was present throughout the year at the forest site and was associated with the adipocere-like stage. Ants played an important role producing post-mortem injuries to the carcasses. Insects of 32 species are reported as being useful in community level approaches

  5. [Giving medico-legal opinions in cases with suspicion of medical mistake.part 1. between medicine and justice.

    Science.gov (United States)

    Chowaniec, Czesław; Chowaniec, Małgorzata; Wilk, Mateusz

    2017-01-01

    Creating medico-legal opinion is a sophisticated investigative, analytical, decision-making and creative process. Forensic medicine specialist in cooperation with clinical medicine consultants, on the basis of evidence analysis, which was gathered during procedures and contained in the acts has to create an objective and essential opinion. This opinion is a vital, very important and irreplaceable proof in every case. Judicial body consults with forensic medicine specialist or specialists if there are circumstances for settlement of which there is a need of classified informations - art. 193 of Penalty Code. Forensic medicine specialists face many difficulties which may have effect on quality, positiveness of opinion, compliance with the deadline, increasing expectancy of judicial body or sides. It is very difficult to find clinical specialists which except their clinical knowledge have basic knowledge about law, the role and duties of an court expert. In this article we discuss creating-opinion problems, role and position of court expert in confrontation with expectations of judicial body and the Justice with particular emphasis on medical mistakes and assessment of medical proceedings. We show the complexity of creating of medical opinions, especially these institutional.

  6. Sudden and unexpected childhood deaths investigated at the Pretoria Medico-Legal Laboratory, South Africa, 2007 - 2011.

    Science.gov (United States)

    Van Deventer, B S; Rossouw, S H; Du Toit-Prinsloo, L

    2016-09-06

     Sudden and unexpected death is well known to occur in infants, and although sudden deaths are less frequent after the first birthday, they still account for a significant proportion of childhood deaths. In 2009, 1.9% of the total deaths in the USA were childhood deaths. In South Africa (SA) this proportion was much higher at 11.85%. According to the law, sudden and unexpected deaths are generally investigated as unnatural deaths. Establishing an exact underlying anatomical cause of death will depend on available resources and can be difficult in a substantial proportion of cases.  A retrospective descriptive case audit was conducted at the Pretoria Medico-Legal Laboratory (PMLL), SA, from 1 January 2007 through to 31 December 2011. All children aged 1 - 18 years who died suddenly and unexpectedly were included.  Ninety-eight cases were identified, which constituted nearly 1% of total admissions to the PMLL. The majority of the deaths were of children aged 1 - 5 years, and the male/female ratio was 1.04:1. In the largest proportion of cases (n=28, 28.6%), the medicolegal investigation, including autopsy and ancillary investigations, did not establish an underlying anatomical cause of death. In the cases where a cause of death was established, pneumonia was the most common diagnosis (n=22, 22.4%).  The fact that the cause of the largest proportion of deaths could not be ascertained emphasises the need for consideration of additional investigative techniques, such as molecular/genetic screening, which have provided an underlying cause of death in a significant number of cases in other countries. There is a lack of published research on the causes and incidence of sudden unexpected deaths in children in SA, and further research in this area is needed.

  7. Toward a standardized investigation protocol in sudden unexpected deaths in infancy in South Africa: a multicenter study of medico-legal investigation procedures and outcomes.

    Science.gov (United States)

    du Toit-Prinsloo, Lorraine; Dempers, Johan; Verster, Janette; Hattingh, Christa; Nel, Hestelle; Brandt, V D; Jordaan, Joyce; Saayman, Gert

    2013-09-01

    South Africa manifests a socio-economic dichotomy that shows features of both a developed and developing country. As a result of this, areas exist where a lack of resources and expertise prevents the implementation of a highly standardized protocol for the investigation of sudden and unexpected deaths in infants (SUDI). Although the medico-legal mortuaries attached to academic centers have the capacity to implement standardized protocols, a previous study conducted at two large medico-legal mortuaries indicated otherwise. This study also revealed that the exact number and incidence of sudden infant death syndrome (SIDS) cases was unknown. These findings prompted a multicenter study of the medico-legal investigation procedures and outcomes in five academic centers in South Africa. A retrospective case audit was conducted for a 5-year period (2005-2009) at medico-legal laboratories attached to universities in Bloemfontein, Cape Town-Tygerberg, Durban, Johannesburg, and Pretoria. The total case load as well as the total number of infants younger than 1 year of age admitted to these mortuaries was documented. The case files on all infants younger than 1 year of age who were admitted as sudden and unexpected or unexplained deaths were included in the study population. Data collected on the target population included demographic details, the nature and scope of the post-mortem examinations, as well as the final outcome (cause of death). A total case load of 80,399 cases were admitted to the mortuaries over the 5 year period with a total of 3,295 (6.5 %) infants. In the infant group, 591 (0.7 %) died from non-natural causes and 2,704 (3.3 %) cases of sudden, unexpected and/or unexplained deaths in infants were admitted and included in the detailed case analysis study. One hundred and ninety-nine babies were between 0 and 7 days of age and 210 babies between 8 and 30 days. The remaining 2,295 infants were between 1 month and 12 months of age. Death scene investigation was

  8. Medico-legal aspects of congenital heart diseases in buying and selling of pets

    Directory of Open Access Journals (Sweden)

    Annamaria Passantino

    2017-01-01

    Full Text Available Aim: The veterinarian should be able to assess congenital and inherited malformations such as heart defects because they may be object of legal disputes. In this study, the authors report some cases of congenital heart defects in pets (dogs and cats to clarify whether or not they may be considered a redhibitory defect. Materials and Methods: A total of 28 medical records of pets referred with suspected congenital heart disease were examined. All patients aged between 3 and 24 months underwent clinical examination, chest X-ray examination, electrocardiogram, and echocardiography and angiocardiography when necessary. Results: Congenital heart diseases or associated cardiac malformations were confirmed. Considering the above congenital diseases as redhibitory defect and the rights of the owners from a strictly legal viewpoint, 9 owners demanded an estimatory action and 11 a redhibitory action; 1 owner decided to demand the reimbursement of veterinary expenses because the animal died; 7 owners took no legal action but requested surgical intervention. Conclusions: Until more appropriate and detailed legislation on the buying and selling of pet animals is put in place; the authors propose to include in the contract a temporal extension of the guarantee relating to congenital heart disease, which can often become evident later.

  9. The Impact of the Danish Medico-Legal Council on the Choice Between Treatment and Punishment for Non-psychotic Offenders

    DEFF Research Database (Denmark)

    Gottlieb, Peter; Gabrielsen, Gorm; Kørner, Alex

    2014-01-01

    punishment and treatment in cases of offenders falling under §69 of the Penal Code, i.e. mentally disordered, although not psychotic offenders. Methods. In 298 cases of defendants who according to the Medico-Legal Council might fall under §69 the recommendations of the assessment reports, the recommendations...... some measure of treatment was about 50% for adult males, and higher for adolescents and for females. In court, however, the two genders as well as adolescents and adults alike all had the same probability, approximately 50%, of being sentenced with treatment instead of punishment. When measured...

  10. Topological materials discovery using electron filling constraints

    Science.gov (United States)

    Chen, Ru; Po, Hoi Chun; Neaton, Jeffrey B.; Vishwanath, Ashvin

    2018-01-01

    Nodal semimetals are classes of topological materials that have nodal-point or nodal-line Fermi surfaces, which give them novel transport and topological properties. Despite being highly sought after, there are currently very few experimental realizations, and identifying new materials candidates has mainly relied on exhaustive database searches. Here we show how recent studies on the interplay between electron filling and nonsymmorphic space-group symmetries can guide the search for filling-enforced nodal semimetals. We recast the previously derived constraints on the allowed band-insulator fillings in any space group into a new form, which enables effective screening of materials candidates based solely on their space group, electron count in the formula unit, and multiplicity of the formula unit. This criterion greatly reduces the computation load for discovering topological materials in a database of previously synthesized compounds. As a demonstration, we focus on a few selected nonsymmorphic space groups which are predicted to host filling-enforced Dirac semimetals. Of the more than 30,000 entires listed, our filling criterion alone eliminates 96% of the entries before they are passed on for further analysis. We discover a handful of candidates from this guided search; among them, the monoclinic crystal Ca2Pt2Ga is particularly promising.

  11. Medico legal issues.

    Science.gov (United States)

    Mackenzie, Geraldine; Carter, Hugh

    2010-01-01

    This chapter gives an educational overview of: * An awareness of the legal issues involved in health informatics * The need for the privacy and security of the patient record * The legal consequences of a breach of the security of the patient record * The concept of privacy law and what precautions ought to be taken to minimize legal liability for a breach of privacy and/or confidentiality.

  12. Organ retention and communication of research use following medico-legal autopsy: a pilot survey of university forensic medicine departments in Japan.

    Science.gov (United States)

    Tsujimura-Ito, Takako; Inoue, Yusuke; Yoshida, Ken-ichi

    2014-09-01

    This study investigated the circumstances and problems that departments of forensic medicine encounter with bereaved families regarding samples obtained from medico-legal autopsies. A questionnaire was posted to all 76 departments of forensic medicine performing medico-legal autopsies in Japan, and responses were received from 48 (63.2%). Of the respondents, 12.8% had approached and communicated with bereaved families about collecting samples from the deceased person during an autopsy and the storage of the samples. In addition, 23.4% of these had informed families that samples might be used in research. Eighteen departments had received enquiries and requests from families about the samples, with most requests concerning their return. The response to such requests varied according to the department. Few departments interacted with the bereaved families regarding the procedure for obtaining autopsy samples, and their methods for handling family concerns differed depending on the person within the department authorised to contact the family. Moreover, the procedures for engaging in such communication have long been unclear, and no legal or ethical consensus or agreement with the general public has been established. It is important for researchers to further discuss the correct way for forensic medicine departments to communicate with bereaved families. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. Carbon Nanotubes Filled with Ferromagnetic Materials

    Directory of Open Access Journals (Sweden)

    Albrecht Leonhardt

    2010-08-01

    Full Text Available Carbon nanotubes (CNT filled with ferromagnetic metals like iron, cobalt or nickel are new and very interesting nanostructured materials with a number of unique properties. In this paper we give an overview about different chemical vapor deposition (CVD methods for their synthesis and discuss the influence of selected growth parameters. In addition we evaluate possible growth mechanisms involved in their formation. Moreover we show their identified structural and magnetic properties. On the basis of these properties we present different application possibilities. Some selected examples reveal the high potential of these materials in the field of medicine and nanotechnology.

  14. Carbon Nanotubes Filled with Ferromagnetic Materials

    Science.gov (United States)

    Weissker, Uhland; Hampel, Silke; Leonhardt, Albrecht; Büchner, Bernd

    2010-01-01

    Carbon nanotubes (CNT) filled with ferromagnetic metals like iron, cobalt or nickel are new and very interesting nanostructured materials with a number of unique properties. In this paper we give an overview about different chemical vapor deposition (CVD) methods for their synthesis and discuss the influence of selected growth parameters. In addition we evaluate possible growth mechanisms involved in their formation. Moreover we show their identified structural and magnetic properties. On the basis of these properties we present different application possibilities. Some selected examples reveal the high potential of these materials in the field of medicine and nanotechnology. PMID:28883334

  15. Colloid transport in model fracture filling materials

    Science.gov (United States)

    Wold, S.; Garcia-Garcia, S.; Jonsson, M.

    2010-12-01

    Colloid transport in model fracture filling materials Susanna Wold*, Sandra García-García and Mats Jonsson KTH Chemical Science and Engineering Royal Institute of Technology, SE-100 44 Stockholm, Sweden *Corresponding author: E-mail: wold@kth.se Phone: +46 8 790 6295 In colloid transport in water-bearing fractures, the retardation depends on interactions with the fracture surface by sorption or filtration. These mechanisms are difficult to separate. A rougher surface will give a larger area available for sorption, and also when a particle is physically hindered, it approaches the surface and enables further sorption. Sorption can be explained by electrostatics were the strongest sorption on minerals always is observed at pH below pHpzc (Filby et al., 2008). The adhesion of colloids to mineral surfaces is related to the surface roughness according to a recent study (Darbha et al., 2010). There is a large variation in the characteristics of water-bearing fractures in bedrock in terms of aperture distribution, flow velocity, surface roughness, mineral distributions, presence of fracture filling material, and biological and organic material, which is hard to implement in modeling. The aim of this work was to study the transport of negatively charged colloids in model fracture filling material in relation to flow, porosity, mineral type, colloid size, and surface charge distribution. In addition, the impact on transport of colloids of mixing model fracture filling materials with different retention and immobilization capacities, determined by batch sorption experiments, was investigated. The transport of Na-montmorillonite colloids and well-defined negatively charged latex microspheres of 50, 100, and 200 nm diameter were studied in either columns containing quartz or quartz mixed with biotite. The ionic strength in the solution was exclusively 0.001 and pH 6 or 8.5. The flow rates used were 0.002, 0.03, and 0.6 mL min-1. Sorption of the colloids on the model fracture

  16. 21 CFR 872.3310 - Coating material for resin fillings.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coating material for resin fillings. 872.3310... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3310 Coating material for resin fillings. (a) Identification. A coating material for resin fillings is a device intended to be applied to the...

  17. [Permanent essential defacement--remarks on the possibilities of verification of the accepted criteria in medico-legal certification in criminal and civil law proceedings].

    Science.gov (United States)

    Chowaniec, Czesław; Nowak, Agnieszka; Jabłoński, Christian; Neniczka, Stanisława

    2007-01-01

    Despite the fact that some criteria of medico-legal certification in criminal and civil proceedings have been established, there are still some topics which are controversial and thus require modification. This is also true of the notion of "permanent essential defacement". In the opinion of the authors, changes in social conventions that are occurring nowadays, as well as a highly diversified, subjective perception of esthetic values indicate the need for discussing a possible modification of the presently obligatory criteria. Apart from the assessment of posttraumatic changes, an important problem is posed by defining the notion of "a part of the body customarily open to the view ". Additionally, the authors bring up for discussion the issue of experts taking into consideration the age and sex of the victims while assessing damages. A separate problem lies in difficulties in assessing the degree of detriment to health because of defacement due to the fact that official tables for evaluating permanent or long-term detriment to health do not include relevant information.

  18. Social isolation and delayed discovery of bodies in houses: the value of forensic pathology, anthropology, odontology and entomology in the medico-legal investigation.

    Science.gov (United States)

    Archer, M S; Bassed, R B; Briggs, C A; Lynch, M J

    2005-07-16

    The bodies of socially isolated people may remain undiscovered in their own houses for prolonged periods. Occasionally the body is in situ for sufficient time to become skeletonised, or partially so. Medico-legal investigation of these cases is complicated by degradation and contamination of evidence. Thus, a multidisciplinary forensic investigation is recommended. The potential contributions of forensic pathology, anthropology, odontology and entomology are outlined here with reference to two cases that occurred in Victoria, Australia, in 2003. Forensic pathologists are often unable to determine the cause of death in skeletonised bodies, however, they may find evidence to support either a natural or unnatural mode of death, and they may describe skeletal pathology or trauma, and identify skeletal features to support radiological identification of the deceased. Anthropologists can provide supplementary evidence of skeletal trauma. Additionally, they can assess age, sex, stature and racial affiliation from skeletal remains. Odontologists can identify individuals through comparison with ante-mortem dental records; however, potential difficulties exist in identifying the treating dentist of a socially isolated person. Odontologists may also examine the teeth and oro-facial skeleton for trauma. Entomologists may estimate minimum death time and/or season of death. Entomological examination of insect remains may also confirm that a body has lain in situ for a considerable period.

  19. Sorption of Np (Ⅴ) on Beishan granite fracture filling materials

    International Nuclear Information System (INIS)

    Jiang Tao; Wang Bo; Bao Liangjin; Zhou Duo; Long Haoqi; Song Zhixin; Chen Xi

    2012-01-01

    The sorption behaviors of Np (Ⅴ) on the granite fracture filling materials were studied by batch experiments under anaerobic in Beishan groundwater. The impact of pH of groundwater, CO 3 2- , humic acid and different components of granite fracture filling materials on sorption of Np (Ⅴ) was investigated. The results show that the granite fracture filling materials have strong capacity of Np (Ⅴ) adsorption. The value of K d , for Np (Ⅴ) sorption on the granite fracture filling materials is 843 mL/g. With the increase of pH, the value of K d increases at first and then decreases. K d of Np sorption on granite fracture filling materials in the presence of CO 3 2- and humic acid decreases. The chlorite and feldspar are major contributors to the sorption of Np (Ⅴ) on Beishan granite fracture filling materials. (authors)

  20. Biocompatibility of root-end filling materials: recent update

    Directory of Open Access Journals (Sweden)

    Payal Saxena

    2013-08-01

    Full Text Available The purpose of a root-end filling is to establish a seal between the root canal space and the periradicular tissues. As root-end filling materials come into contact with periradicular tissues, knowledge of the tissue response is crucial. Almost every available dental restorative material has been suggested as the root-end material of choice at a certain point in the past. This literature review on root-end filling materials will evaluate and comparatively analyse the biocompatibility and tissue response to these products, with primary focus on newly introduced materials.

  1. [Epidemiology of the medico-legal risk associated with the practice of ambulatory surgery in France: a study based on insurance data].

    Science.gov (United States)

    Theissen, A; Fuz, F; Catineau, J; Sultan, W; Beaussier, M; Carles, M; Raucoules-Aimé, M; Niccolai, P

    2014-03-01

    The medico-legal risk specifically associated with the practice of ambulatory surgery is still not well studied. SHAM insurances are the biggest French provider of medical liability insurances. The study of the insurance claims provided by this insurer is therefore a relevant source of data on the complications related to ambulatory surgery. The aim of this study was to compare the claim rate related to ambulatory surgery with non-ambulatory surgery. We did a retrospective study on insurance claims provided by SHAM insurances between 2007 and 2011 to compare the claim rate related to ambulatory surgery with non-ambulatory surgery. We searched the files in the SHAM database, and then analyzed them. On the study period, out of a total of 29565 registered claims, 467 (1.6%) originated from ambulatory surgery. On the total of 29,098 registered claims for non-ambulatory surgery, 2151 (7.4%) led to a condemnation whereas the rate was 7% (33 out of 467 claims) for ambulatory surgery. The condemnations linked to ambulatory surgery amounted to 1.5% of the total (33 out of 2184), for a cost of 1.7 M€ (versus 400,3 M€ for non-ambulatory surgery). The average cost of a compensation is therefore 50,500 € for ambulatory surgery and 186,000 € for non-ambulatory surgery. The medical specialties concerned are primarily ophthalmology, abdominal and orthopedics surgery. The main identified causes were medical errors (n=16) and nosocomial infections (n=13). The claim rate in ambulatory surgery is proportionally less frequent with compensations three times less and were related to the most frequent type of surgery done in ambulatory settings. These data should help strengthen quality approach in ambulatory surgery. Copyright © 2014 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  2. The medico-legal investigation of sudden, unexpected and/or unexplained infant deaths in South Africa: where are we--and where are we going?

    Science.gov (United States)

    du Toit-Prinsloo, L; Dempers, J J; Wadee, S A; Saayman, G

    2011-03-01

    Sudden Infant Death Syndrome (SIDS) has been reported to be the leading cause of death in infants under 1 year of age in many countries. Unfortunately, a paucity of published research data exists in South Africa, with regard to the incidence of and investigation into the circumstances surrounding Sudden Unexplained Deaths in Infants (SUDI) and/or SIDS. Currently, even though most academic centers conform to a protocol consistent with internationally accepted standards, there exists no nationally accepted infant death investigation protocol in South Africa. It is the aim of this study to review the current practice of infant death investigation in two representative but geographically and demographically distinct centers. Retrospective case audit over a five-year period (2000-2004) was conducted at two large medico-legal mortuaries in Pretoria (Gauteng) and Tygerberg (Cape Town). Case files on all infants younger than 1 year of age were reviewed. The outcome measures included number of deaths, demographic details and the nature and final outcome of the post mortem examinations. A total of 512 cases were identified as possible SIDS cases and of these, 171 was classified as SIDS. The study showed marked inter-case and inter-divisional variation in terms of the investigation of infant deaths at the two institutions. It is envisaged that this study will focus attention on the current lack of usable data regarding sudden/unexplained/unexpected infant deaths in South Africa, and aid in the formulation and implementation of a practical (yet internationally accountable) infant death investigation protocol, which could facilitate comparisons with other countries and initiate further structured research in this field.

  3. Patterns of abuse amongst Sri Lankan women returning home after working as domestic maids in the Middle East: An exploratory study of medico-legal referrals.

    Science.gov (United States)

    Wickramage, Kolitha; De Silva, Malintha; Peiris, Sharika

    2017-01-01

    Migrant worker abuse is well recognised, but poorly characterised within the scientific literature. This study aimed to explore patterns of abuse amongst Sri Lankan women returning home after working as domestic maids. Sri Lanka has over 2 million of its citizens employed overseas as international labor migrants. A cross-sectional study was conducted on Sri Lankan female domestic maids returning from the Middle East region who were referred for medico-legal opinion. A total of 20 women were included in the study. Average length of their employment overseas was 14 months. Complaints of physical violence directed mainly through their employers were made by 60% of women. Upon physical examination, two-thirds had evidence of injuries, with a third being subjected to repetitive/systematic violence. Eighty percent suffered some form of psychological trauma. Personal identity papers and travel documents had been confiscated by the employer in 85% of cases, with two thirds indicating they were prevented and/or restricted from leaving their place of work/residence. Our study demonstrates that female domestic maid abuse manifests through multiple pathways. Violence against such workers span the full spectrum of physical, financial, verbal, emotional abuse and neglect, as defined by the World Health Organization. Findings from this exploratory study cannot be generalized to the large volume of migrant worker outflows. Further research is needed to determine incidence and define patterns in other migrant worker categories such as low-skilled male workers. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  4. Suicide among nursing home residents in Australia: A national population-based retrospective analysis of medico-legal death investigation information.

    Science.gov (United States)

    Murphy, Briony J; Bugeja, Lyndal C; Pilgrim, Jennifer L; Ibrahim, Joseph E

    2018-05-01

    Suicide among nursing home residents is a growing public health concern, currently lacking in empirical research. This study aims to describe the frequency and nature of suicide among nursing home residents in Australia. This research comprised a national population-based retrospective analysis of suicide deaths among nursing home residents in Australia reported to the Coroner between July 2000 and December 2013. Cases were identified using the National Coronial Information System, and data collected from paper-based coroners' records on individual, incident, and organizational factors, as well as details of the medico-legal death investigation. Data analysis comprised univariate and bivariate descriptive statistical techniques; ecological analysis of incidence rates using population denominators; and comparison of age and sex of suicide cases to deaths from other causes using logistic regression. The study identified 141 suicides among nursing home residents, occurring at a rate of 0.02 deaths per 100 000 resident bed days. The ratio of deaths from suicide to deaths from any other cause was higher in males than females (OR = 3.56, 95%CI = 2.48-5.12, P = home for less than 12 months (n = 71, 50.3%). Common major life stressors identified in suicide cases included the following: health deterioration (n = 112, 79.4%); isolation and loneliness (n = 60, 42.6%); and maladjustment to nursing home life (n = 42, 29.8%). This research provides a foundational understanding of suicide among nursing home residents in Australia and contributes important new information to the international knowledge base. Copyright © 2018 John Wiley & Sons, Ltd.

  5. Mechanical behaviour of dental composite filling materials using digital holography

    OpenAIRE

    Monteiro, J.M.; Lopes, H.; Vaz, M.A.P.; Campos, J.C. Reis

    2010-01-01

    One of the most common clinical problems in dentistry is tooth decay. Among the dental filling materials used to repair tooth structure that has been destroyed by decay are dental amalgam and composite materials based on acrylics. Dental amalgam has been used by dentists for the past 150 years as a dental restorative material due to its low cost, ease of application, strength, durability, and bacteriostatic effects. However its safety as a filling material has been questioned due to th...

  6. CHARACTERISTICS OF FLORIDA FILL MATERIALS AND SOILS 1990

    Science.gov (United States)

    The report gives results of laboratory work by the University of Florida in support of the Foundation Fill Data Base project of the Foundation Fill Materials Specifications Task Area of the Florida Radon Research Program (FRRP). Work included determination of radon concentrations...

  7. Effect of Different Filling Materials in Anammox Bacteria Enrichment

    Directory of Open Access Journals (Sweden)

    Dilek ÖZGÜN

    2012-12-01

    Full Text Available Purpose: Anaerobic ammonium oxidation (Anammox is a process that ammonium as electron donor is oxidized to nitrogen gas using nitrite as electron acceptor. Compared to conventional nitrification-denitrification processes, this process is used less oxygen and no organic material (methanol, glucose. However, the slow growth rate of Anammox bacteria (11-30 days is disadvantages. Therefore, batch reactors have been carried out in these bacteria enrichment. In this study continuously operated upflow anaerobic sludge reactor (UASB using different filling materials disposing of sensitive and slow-growing Anammox bacteria out of the system is purposed. Design and Methods: System is operated up-flow column reactor at 2 days hydraulic retention time (HRT in 45 days. In this study, ceramic stones and Linpor filling material are used. Using synthetic wastewater containing ammonium and nitrite, Ar/CO2 anaerobic conditions (95/5% supplied with gas. System is operated at a temperature 253 C in UASB. Temperature, pH, ammonia-nitrogen and nitrite nitrogen are measured. Results: Both filling material reactors are operated in 45 days. Ceramic stones filling reactor is observed quickly reaches 90% were used reactor ammonium removal. The ammonium nitrogen removal was slower in Linpor filling materials reactor. Nitrite removal is reached up to 90% in both the reactor. When compared to the stoichiometric equation in Linpor was composed of large amounts of nitrate. At the end of 25 days the results were similar to ceramic stone filling reactor with Linpor filling material reactors. Conclusions and Original Value: Anammox process as from nitrogen removal processes was discovered in 1995. Anammox bacteria that make up this process due to very low growth rates of microbial bacteria in the system must be kept in the system. Most of the studies in the literature, these bacteria enrichment stage is started instead of a continuous batch reactor system. In this study

  8. Experimental study of strontium sorption on fissure filling material

    Energy Technology Data Exchange (ETDEWEB)

    Eriksen, T E; Cui, Daqing [Royal Institute of Technology, Stockholm (Sweden). Dept. of Chemistry

    1994-12-01

    We have carried out a comparative study of sorption and desorption of strontium in groundwater on separated magnetic and size fractions of fissure filling material taken from natural fissures in granitic rock. Complete reversibility of the sorption process was demonstrated by identical Freundlich isotherms, isotopic exchangeability and pH dependence of the distribution coefficients Rd. The sorption was found to be strongly pH dependent in the range 3-11. The pH effect can be accommodated in the sorption model by considering the surface areas and surface charges of the minerals in the fissure filling material. 20 refs, 9 figs, 3 tabs.

  9. Experimental study of strontium sorption on fissure filling material

    International Nuclear Information System (INIS)

    Eriksen, T.E.; Cui, Daqing

    1994-12-01

    We have carried out a comparative study of sorption and desorption of strontium in groundwater on separated magnetic and size fractions of fissure filling material taken from natural fissures in granitic rock. Complete reversibility of the sorption process was demonstrated by identical Freundlich isotherms, isotopic exchangeability and pH dependence of the distribution coefficients Rd. The sorption was found to be strongly pH dependent in the range 3-11. The pH effect can be accommodated in the sorption model by considering the surface areas and surface charges of the minerals in the fissure filling material. 20 refs, 9 figs, 3 tabs

  10. Experimental Study of Goaf Filling Materials Based on Red Mud

    Science.gov (United States)

    Mu, Mangen; Gao, Xiaozhen; Guo, Taoming; Hu, Xinping

    2018-01-01

    Red mud as soild waste is difficult to treatment. Goaf filling materials can make a large use of red mud. By the experimental study,we find that the red mud, fly ash, ground slag and desulfida-tion gypsum can be used to make goaf filling materials based on the principle of alkali excitation and metalion stability.Through the control variable method, we find that the optimal proportion of goaf filling materials based on red mud is red mud 55%, fly ash 30%, cement 7.5%, fly ash 2.5%, desulfurization gypsum 5%, admixture 1%, and water solid ratio=1:1.2.The 28days final material strength was 2.0 MPa,which achives the technical specification requirements.Through the test of SEM, XRD and IR, it is indicated that the strength formation of goaf filling material based on red mud is from the unformed linking hydration products of amorphous alkali excitation system. With curing time from 3 to 7 days, the unformed linking hydration products grown a lot of vitreous hydration products. When hydration reaction basicly finished after 28 days, the hydration products have developed into a large volume of massive vitreous with an extremely dense structure. The Ca2SiO3 mineral phase is significantly reduced, which is participate in hydration reactions. The decrease of Ca2SiO3 indicates that the Si-O bond in the system have been ruptured and reorganized.

  11. Multifunctional composite material based on carbon-filled polyurethane

    International Nuclear Information System (INIS)

    Malinovskaya, T; Melentyev, S; Pavlov, S

    2015-01-01

    The research paper deals with the performance of composite resistive material heating coatings based on the polyurethane binder, filled with colloidal-graphite preparation C- 1, which can be used in structures of electric heaters. Frequency dependences of transmission and reflection coefficients, dielectric permeability of composite materials with the various content of carbon fillers (technical carbon, graphite) in polyurethane varnish in ranges of frequencies 26-40 GHz and 110-260 GHz are experimentally investigated. (paper)

  12. Contrast material filling of the peroneal tendon sheath

    International Nuclear Information System (INIS)

    Zadravecz, Gy.; Grexa, E.

    1981-01-01

    In case of complaints after fracture of the calcaneus the common sheath of the peroneus tendons was filled up with contrast material. The tendon sheath was punctured Oehind the external ankle. The three-directional radiograms clearly showed the dislocation and compression of the tendons, caused by the exostosis of the calcaneus. The concomitant tendovaginitis caused the complaints. This alteration was observed in 11% of all the calcaneus fractures. (L.E.)

  13. Innovations in endodontic filling materials: guttapercha vs Resilon.

    Science.gov (United States)

    de Souza Filho, Francisco José; Gallina, Giuseppe; Gallottini, Livio; Russo, Riccardo; Cumbo, Enzo Maria

    2012-01-01

    One of the goals of endodontic treatment is to achieve a complete, tridimensional, hermetic sealing of the root canal system to prevent the entry of microorganisms or their products through both the coronal and apical pathways. Gutta-percha is the most widely used material for root canal filling and despite its numerous properties, such as biocompatibility and thermoplasticity, it has however an important limit: the lack of adhesion to the canal walls. Attempts to address this problem have been made over the years by using endodontic cements capable of bonding to canal dentine but their tendency to resorption in time can compromise the quality of treatment. The first step towards a real adhesive endodontic filling(4) is rather recent; in fact, it goes back to 2003 when, on the occasion of the American Dental Association (ADA) Annual Session, Resilon Research LLC introduced a new canal filling adhesive system based on a thermoplastic synthetic resin material called Resilon™. The real innovation of this system is its capacity of creating a core made of Resilon™ bonded to the cement which adheres to dentine walls previously conditioned with a self-etching primer(4) so no changes in the techniques of canal preparation are required. The aim of this study was to evaluate the capacity of two filling materials (gutta-percha and Resilon) to adapt to the canal anatomy, especially on the apical third, using the continuous wave of condensation technique. Our data suggest that in the third apical the gutta-percha best shows rheological properties that are as important as the bond capability.

  14. Comparative evaluation of low cost materials as constructed wetland filling media

    Science.gov (United States)

    Pinho, Henrique J. O.; Vaz, Mafalda M.; Mateus, Dina M. R.

    2017-11-01

    Three waste materials from civil construction activities were assessed as low cost alternative filling materials used in Constructed Wetlands (CW). CW are green processes for wastewater treatment, whose design includes an appropriate selection of vegetation and filling material. The sustainability of such processes may be incremented using recovered wastes as filling materials. The abilities of the materials to support plant growth and to contribute to pollutants removal from wastewater were assessed and compared to expanded clay, a filling usually used in CW design. Statistical analysis, using one-way ANOVA and Welch's ANOVA, demonstrate that limestone fragments are a better choice of filling material than brick fragments and basalt gravel.

  15. Color of bulk-fill composite resin restorative materials.

    Science.gov (United States)

    Barutcigil, Çağatay; Barutcigil, Kubilay; Özarslan, Mehmet Mustafa; Dündar, Ayşe; Yilmaz, Burak

    2018-03-01

    To evaluate the color stability of novel bulk-fill composite resins. Color measurements of a nanohybrid composite resin (Z550) and 3 bulk-fill composite resins (BLK, AFX, XTF; n = 45) were performed before polymerization. After polymerization, color measurements were repeated and specimens were immersed in distilled water or red wine, or coffee. Color change [CIEDE2000 (ΔE 00 )] was calculated after 24 h, 1 and 3 weeks. Data were analyzed with Kruskal-Wallis, Mann-Whitney U and Wilcoxon tests (α = 0.05). Color changes observed after polymerization were significant for all groups. Color changes observed in distilled water for Z550 and AFX were significant. Color changes after stored in red wine and coffee were significant for all groups. Bulk-fill composite resin color change increased over time for all groups in red wine and coffee (P composite resin and bulk-fill composite resins. AFX had the highest color change in distilled water. The color of tested bulk-fill composite resins significantly changed after immersion in beverages and over time. Color change observed with the nanohybrid composite resin after 1 week was stable. Clinicians should keep in mind that tested composite resins may change color when exposed to water and significantly change color immediately after they are polymerized. In addition, the color change continues over time should the patient is a coffee and/or red wine consumer. © 2017 Wiley Periodicals, Inc.

  16. The application of waste fly ash and construction-waste in cement filling material in goaf

    Science.gov (United States)

    Chen, W. X.; Xiao, F. K.; Guan, X. H.; Cheng, Y.; Shi, X. P.; Liu, S. M.; Wang, W. W.

    2018-01-01

    As the process of urbanization accelerated, resulting in a large number of abandoned fly ash and construction waste, which have occupied the farmland and polluted the environment. In this paper, a large number of construction waste and abandoned fly ash are mixed into the filling material in goaf, the best formula of the filling material which containing a large amount of abandoned fly ash and construction waste is obtained, and the performance of the filling material is analyzed. The experimental results show that the cost of filling material is very low while the performance is very good, which have a good prospect in goaf.

  17. Computed tomography assessment of the efficiency of different techniques for removal of root canal filling material

    International Nuclear Information System (INIS)

    Dall'agnol, Cristina; Barletta, Fernando Branco; Hartmann, Mateus Silveira Martins

    2008-01-01

    This study evaluated the efficiency of different techniques for removal of filling material from root canals, using computed tomography (CT). Sixty mesial roots from extracted human mandibular molars were used. Root canals were filled and, after 6 months, the teeth were randomly assigned to 3 groups, according to the root-filling removal technique: Group A - hand instrumentation with K-type files; Group B - reciprocating instrumentation with engine-driven K-type files; and Group C rotary instrumentation with engine-driven ProTaper system. CT scans were used to assess the volume of filling material inside the root canals before and after the removal procedure. In both moments, the area of filling material was outlined by an experienced radiologist and the volume of filling material was automatically calculated by the CT software program. Based on the volume of initial and residual filling material of each specimen, the percentage of filling material removed from the root canals by the different techniques was calculated. Data were analyzed statistically by ANOVA and chi-square test for linear trend (α=0.05). No statistically significant difference (p=0.36) was found among the groups regarding the percent means of removed filling material. The analysis of the association between the percentage of filling material removal (high or low) and the proposed techniques by chi-square test showed statistically significant difference (p=0.015), as most cases in group B (reciprocating technique) presented less than 50% of filling material removed (low percent removal). In conclusion, none of the techniques evaluated in this study was effective in providing complete removal of filling material from the root canals. (author)

  18. Computed tomography assessment of the efficiency of different techniques for removal of root canal filling material

    Energy Technology Data Exchange (ETDEWEB)

    Dall' agnol, Cristina; Barletta, Fernando Branco [Lutheran University of Brazil, Canoas, RS (Brazil). Dental School. Dept. of Dentistry and Endodontics]. E-mail: fbarletta@terra.com.br; Hartmann, Mateus Silveira Martins [Uninga Dental School, Passo Fundo, RS (Brazil). Postgraduate Program in Dentistry

    2008-07-01

    This study evaluated the efficiency of different techniques for removal of filling material from root canals, using computed tomography (CT). Sixty mesial roots from extracted human mandibular molars were used. Root canals were filled and, after 6 months, the teeth were randomly assigned to 3 groups, according to the root-filling removal technique: Group A - hand instrumentation with K-type files; Group B - reciprocating instrumentation with engine-driven K-type files; and Group C rotary instrumentation with engine-driven ProTaper system. CT scans were used to assess the volume of filling material inside the root canals before and after the removal procedure. In both moments, the area of filling material was outlined by an experienced radiologist and the volume of filling material was automatically calculated by the CT software program. Based on the volume of initial and residual filling material of each specimen, the percentage of filling material removed from the root canals by the different techniques was calculated. Data were analyzed statistically by ANOVA and chi-square test for linear trend ({alpha}=0.05). No statistically significant difference (p=0.36) was found among the groups regarding the percent means of removed filling material. The analysis of the association between the percentage of filling material removal (high or low) and the proposed techniques by chi-square test showed statistically significant difference (p=0.015), as most cases in group B (reciprocating technique) presented less than 50% of filling material removed (low percent removal). In conclusion, none of the techniques evaluated in this study was effective in providing complete removal of filling material from the root canals. (author)

  19. [Application of hair analysis of selected psychoactive substances for medico-legal purposes. Part II. Cases of complex fatal poisonings: interactions of heroine - cocaine - amphetamines].

    Science.gov (United States)

    Rojek, Sebastian; Kłys, Małgorzata; Rzepecka-Woźniak, Ewa; Konopka, Tomasz

    2010-01-01

    The study represents an attempt at employing segmental hair analysis in complex poisonings with xenobiotic mixtures of heroine - cocaine - amphetamines in the context of the cause of death as a consequence of complex interaction mechanisms which occurred prior to death. Two cases of complex poisonings: heroine - cocaine and heroine - cocaine - amphetamines were analyzed and documented with macro- and microscopic examinations and complex toxicological examinations, including the analysis of classic biological material, i.e. samples of selective blood, and alternative material, i.e. hair samples. Determinations of opioids, cocaine and its metabolite and amphetamines in the hair biological matrix were performed using high performance liquid chromatography--atmospheric pressure chemical ionization--tandem mass spectrometry (HPLC-APCI-MS-MS). Segmental hair analysis of the investigated cases indicated a prolonged intake of similar psychoactive substances and a developed adaptation of the addicted to interaction mechanisms, which, however, led gradually to multiorgan anatomopathological changes, and in consequence to death.

  20. Medico-legal and legal-penal aspects of expert opinions and adjudication in cases of intoxications with intoxicating agents and ethanol-like intoxicants

    Directory of Open Access Journals (Sweden)

    Monika Ćwiklińska

    2015-08-01

    Full Text Available Introduction: The available legal regulations in Poland do not define the concentration thresholds enabling to differentiate between the states of “after-use” versus “under the influence” of a drug, as it is in the case of alcohol. The aim of the study was to analyse jurisdiction in cases regarding the evaluation of the effects of intoxicating agents and ethanol-like intoxicants and to identify ambiguities and gaps in the applicable regulations leading to problems in preparing expert opinions. Material and methods: The material included the opinions of experts in the field of toxicology and forensic medicine made by the Department of Forensic Medicine in Lublin in the years 2009–2011 and records obtained in the process of inquiry from the regional prosecutor’s offices and courts in 52 cases. Results : Amongst 52 cases in which the ordered toxicology examinations demonstrated the presence of intoxicating agents in drivers’ blood (tetrahydrocannabinols in 39 and amphetamine in 21 cases in 2 cases petty offence proceedings were instituted (Art. 87 of the Petty Offence Code although high concentrations of xenobiotics indicated the state of being “under the influence” of a narcotic drug (Art. 178a of the Penal Code. Three cases were discontinued despite expert opinions that the drivers were at least in the after-narcotic use state. In only 3 cases were witnesses asked to provide testimony about the circumstances of the driver’s conduct. Conclusions : The analysis has demonstrated that judicial bodies expect forensic expertise based exclusively on toxicological examination results; when expert findings are inconclusive, they only administer litigations opportunistically applying the principle of the presumption of innocence understood literally. Considering the above, threshold values of “use” and “influence” of the most commonly detected drugs should be urgently determined.

  1. Should a doctor stop rendering medical services? Part II – Analysis of medico-legal conduct in cases of uncertainties regarding informed consent in minors. The Polish perspective

    Directory of Open Access Journals (Sweden)

    Justyna Zajdel

    2014-06-01

    Full Text Available introduction. The doctor’s decision whether to save the life of a minor who has attempted to commit suicide depends on the decision of the person who, under legal regulations, is responsible for the minor. In everyday medical practice doctors are often placed in difficult situations and often cannot make any decision. Such doubts arise when it is impossible to contact the person(s responsible for the minor. The doctor encounters similar issues when the parents of a minor under 16 years of age express different opinions on the recommended procedures, and are against the doctor’s decision and do not want their child to be hospitalized. materials and methods. The current legislation and doctrine was analyzed and an attempt was made to determine the way of conduct with regard to suicidal minors, and algorithmize the way of conduct towards such suicidal minors. The conduct was discussed on the two examples, based on real clinical cases. results. With regard to minors in a clinical state demanding urgent procedures, who have of the decision made by the guardian, and regardless of the fact there is no contact with the guardian. If the status is stable, the physician’s modus operandi depends on various accompanying circumstances. However, he is still obliged to provide medical help. discussion. A practical algorithm is presented and all the possible legal variations discussed and clarified.

  2. Density of loose-fill insulation material exposed to cyclic humidity conditions

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    the granulated loose-fill material is exposed to a climate that is characterised as cyclic humidity conditions (a constant temperature and a relative humidity alternating between two predetermined constant relative humidity levels). A better understanding of the behaviour of granulated loose-fill material...

  3. Neutralization of Aerosolized Bio-Agents by Filled Nanocomposite Materials through Thermal and Chemical Inactivation Mechanisms

    Science.gov (United States)

    2016-06-01

    Bio -agents by Filled Nanocomposite Materials through Thermal and Chemical Inactivation Mechanisms Distribution Statement A. Approved for public...of Cincinnati Project Title: Neutralization of Aerosolized Bio -agents by Filled Nanocomposite Materials through Thermal and Chemical Inactivation...fire ball, where they will not effectively interact with any viable bio -aerosol. 1.1.4. Conclusions Cryo-milling is necessary to achieve a

  4. Non-clinicians' judgments about asylum seekers' mental health: how do legal representatives of asylum seekers decide when to request medico-legal reports?

    Science.gov (United States)

    Wilson-Shaw, Lucy; Pistrang, Nancy; Herlihy, Jane

    2012-01-01

    Procedures for determining refugee status across Europe are being speeded up, despite the high prevalence of mental health difficulties among asylum seekers. An assurance given is that ''vulnerable applicants'' will be identified and excluded from accelerated procedures. Although experts have recommended assessments to be undertaken by experienced clinicians, this is unlikely to happen for political and financial reasons. Understanding how non-clinically qualified personnel perform assessments of mental health issues is timely and crucial. Misrecognition of refugees due to the inappropriate use of accelerated procedures involves the risk of returning the very people who have the right to protection from further persecution. To examine the decision making of immigration lawyers, who are an example of a group of nonclinicians who decide when and whether to refer asylum-seekers for psychiatric assessment. Semi-structured interviews were conducted with 12 legal representatives working with people seeking refugee or human rights protection in the United Kingdom. The resultant material was analysed using Framework Analysis. Themes clustered around the legal case, the client, the representative and the systems, all with sub-themes. A mapping exercise integrated these themes to show how representatives brought together questions of (1) evidential reasons for a report, influenced by their legal, psychological and case law knowledge, and (2) perceived evidence of mental distress, influenced by professional and personal experiences and expectations. The legal representatives interviewed were well-informed and trained in psychological issues as well as clearly dedicated to their clients. This helped them to attempt quasi-diagnoses of common mental health problems. They nonetheless demonstrated stereotypical understanding of post-traumatic stress disorder and other possible diagnoses and the role of subjectivity. The study has implications for other groups - particularly those

  5. Non-clinicians’ judgments about asylum seekers’ mental health: how do legal representatives of asylum seekers decide when to request medico-legal reports?

    Directory of Open Access Journals (Sweden)

    Lucy Wilson-Shaw

    2012-10-01

    Full Text Available Background : Procedures for determining refugee status across Europe are being speeded up, despite the high prevalence of mental health difficulties among asylum seekers. An assurance given is that ‘‘vulnerable applicants’’ will be identified and excluded from accelerated procedures. Although experts have recommended assessments to be undertaken by experienced clinicians, this is unlikely to happen for political and financial reasons. Understanding how non-clinically qualified personnel perform assessments of mental health issues is timely and crucial. Misrecognition of refugees due to the inappropriate use of accelerated procedures involves the risk of returning the very people who have the right to protection from further persecution. Objective : To examine the decision making of immigration lawyers, who are an example of a group of nonclinicians who decide when and whether to refer asylum-seekers for psychiatric assessment. Method : Semi-structured interviews were conducted with 12 legal representatives working with people seeking refugee or human rights protection in the United Kingdom. The resultant material was analysed using Framework Analysis. Results : Themes clustered around the legal case, the client, the representative and the systems, all with sub-themes. A mapping exercise integrated these themes to show how representatives brought together questions of (1 evidential reasons for a report, influenced by their legal, psychological and case law knowledge, and (2 perceived evidence of mental distress, influenced by professional and personal experiences and expectations. Conclusions : The legal representatives interviewed were well-informed and trained in psychological issues as well as clearly dedicated to their clients. This helped them to attempt quasi-diagnoses of common mental health problems. They nonetheless demonstrated stereotypical understanding of post-traumatic stress disorder and other possible diagnoses and the

  6. Medico-legal problems in radiology

    International Nuclear Information System (INIS)

    Becker, W.

    1979-01-01

    The obligation of the pysician to inform the patient - which he has to prove in case of a suit - is based on the patient's right of selfdetermination. This self-dicision information was subject of the panel discussion. Not discussed in detail were the information concerning diagnosis and prognosis, and the instruction of the patient regarding his conduct postoperatively and during medical treatment. Not considered was the so-called malpractice and negligence respectively. Medical liability suits are increasing for various reasons and are frequently directed at a failure to inform the patient because the patient is often unable to prove a negligence of the physician ('surrogate liability'). The dimension of the duty of disclosure (complete information - no information at all) is discussed in general and with special regard to the radiological field. (orig.) [de

  7. medico-legal perspectives in history

    African Journals Online (AJOL)

    Various legal codes dealing with medical malpractice existed in Egypt, Mesopotamia, China, Islam, Greece, Rome, Persia and India. The first documented Code of Laws ever used by human civilisation in, for example, Mesopotamia is to be found from the Law Code of Hammurabi – a textual source of evidence concerning ...

  8. Radiopacity of bulk fill flowable resin composite materials

    African Journals Online (AJOL)

    2015-08-23

    Aug 23, 2015 ... 2017 Nigerian Journal of Clinical Practice | Published by Wolters Kluwer - Medknow. Abstract ... one of the latest trends in dental materials research is the ..... Geneva: International Organisation for Standardization; 2000. 13.

  9. The presence of antimony in various dental filling materials

    International Nuclear Information System (INIS)

    Molokhia, Anat; Combe, E.C.; Lilley, J.D.

    1985-01-01

    Antimony was determined in a number of non-metallic dental materials currently used for tooth restoration. The method applied was instrumental neutron activation analysis. The concentration of antimony in some of the brands tested was found to be as high as 900 fold that in the normal hard dental tissues. (author)

  10. Chemical properties of gutta-percha endodontic filling material: investigation of five commercial brands

    International Nuclear Information System (INIS)

    Silva Junior, Joao Batista A.; Paula, Regina C.M.; Feitosa, Judith P.A.; Gurgel Filho, Eduardo; Teixeira, Fabricio B

    2001-01-01

    Chemical composition e thermal stability of five brands of gutta-percha endodontic filling material were investigated. Samples with higher amount of organic materials possess higher thermal stability. Investigation of gutta-percha polymer extracted from the endodontic filling by IR and NMR shows that the polymer is predominantly trans-polyisoprene. The thermal stability and molar mass were similar for four brands, however the 'Tanari' brand has got lower molar mass value than the other ones. (author)

  11. Designing strip footing foundations using expanded polystyrene (EPS) as fill material

    DEFF Research Database (Denmark)

    Psarropoulos, Prodromos; Zania, Varvara; Spyrakos, Konstantinos

    2010-01-01

    One of the modern uses of expanded polystyrene (EPS) is in strip footings as fill material. The current study investigates the effect of the geofoam filling in the static and seismic design of the base slab founded on strip footings. For this purpose the finite element method is employed, and three......-dimensional as well as two-dimensional parametric analyses are conducted taking into account static and seismic loading conditions. The interaction of the soil–geofoam–foundation system is taken into consideration. The use of EPS as fill material in foundation systems is proven to be not only technically but also...

  12. Portland cement versus MTA as a root-end filling material. A pilot study.

    Science.gov (United States)

    da Silva, Sérgio Ribeiro; da Silva Neto, José Dias; Veiga, Daniela Francescato; Schnaider, Taylor Brandão; Ferreira, Lydia Masako

    2015-02-01

    To assess periradicular lesions clinically and by computed tomography (CT) after endodontic surgery using either Portland cement or mineral trioxide aggregate (MTA) as a root-end filling material. Three patients diagnosed with periradicular lesions by cone-beam CT underwent endodontic surgery with root-end filling. Patient A was treated with MTA as the root-end filling material, patient B was treated with Portland cement and patient C had two teeth treated, one with MTA and the other with Portland cement. Six months after surgery, the patients were assessed clinically and by CT scan and the obtained results were compared. Periradicular tissue regeneration was observed in all cases, with no significant differences in bone formation when comparing the use of MTA and Portland cement as root-end filling materials. Both mineral trioxide aggregate and Portland cement were successful in the treatment of periradicular lesions.

  13. Privacy and Property? Multi-level Strategies for Protecting Personal Interests in Genetic Material

    OpenAIRE

    Laurie, Graeme

    2003-01-01

    The paper builds on earlier medico-legal work by Laurie on privacy in relation to genetic material. In this chapter, the author discusses not only Laurie's views as 'pro-privacy' but the limitations of privacy, particularly once information, genetic or otherwise, enters a public sphere. The article draws on cases and laws in the UK, continental Europe, and the US, to provide a comparative view in suggesting an alternative approach to privacy.

  14. 3D Analysis of D-RaCe and Self-Adjusting File in Removing Filling Materials from Curved Root Canals Instrumented and Filled with Different Techniques

    Directory of Open Access Journals (Sweden)

    Neslihan Simsek

    2014-01-01

    Full Text Available The aim of this study was to compare the efficacy of D-RaCe files and a self-adjusting file (SAF system in removing filling material from curved root canals instrumented and filled with different techniques by using microcomputed tomography (micro-CT. The mesial roots of 20 extracted mandibular first molars were used. Root canals (mesiobuccal and mesiolingual were instrumented with SAF or Revo-S. The canals were then filled with gutta-percha and AH Plus sealer using cold lateral compaction or thermoplasticized injectable techniques. The root fillings were first removed with D-RaCe (Step 1, followed by Step 2, in which a SAF system was used to remove the residual fillings in all groups. Micro-CT scans were used to measure the volume of residual filling after root canal filling, reinstrumentation with D-RaCe (Step 1, and reinstrumentation with SAF (Step 2. Data were analyzed using Wilcoxon and Kruskal-Wallis tests. There were no statistically significant differences between filling techniques in the canals instrumented with SAF (P=0.292 and Revo-S (P=0.306. The amount of remaining filling material was similar in all groups (P=0.363; all of the instrumentation techniques left filling residue inside the canals. However, the additional use of SAF was more effective than using D-RaCe alone.

  15. Effectiveness of rotatory and reciprocating movements in root canal filling material removal

    Directory of Open Access Journals (Sweden)

    Emmanuel João Nogueira Leal SILVA

    2015-01-01

    Full Text Available The purpose of this study was to compare the efficacy of reciprocating and rotary techniques for removing gutta-percha and sealer from root canals. Forty straight and oval single-rooted premolars were prepared up to size 30, filled with gutta-percha and sealer, and then randomly allocated to two experimental retreatment groups: ProTaper Retreatment System (PTRS and WaveOne System (WS. Procedural errors, time of retreatment and apically extruded material were recorded for all the roots. The roots were radiographed after retreatment. The percentage of residual material was calculated using image analysis software. The data were analyzed by Kolmogorov-Smirnov and t tests, with a significance level set at 5%. No system completely removed the root filling material from the root canal. No significant differences were observed between the systems, in terms of residual filling material in any tested third (p > 0.05. WS was faster in removing filling material than PTRS (p< 0.05. Extrusion was observed in 4 cases in PTRS and in 5 cases in WS. No procedural errors were observed in either group. It can be concluded that although no differences were observed in the efficacy of PTRS and WS for removing root filling material, WS was faster than PTRS.

  16. Efficacy of ProTaper universal retreatment files in removing filling materials during root canal retreatment.

    Science.gov (United States)

    Giuliani, Valentina; Cocchetti, Roberto; Pagavino, Gabriella

    2008-11-01

    The aim of this study was to evaluate the efficacy of the ProTaper Universal System rotary retreatment system and of Profile 0.06 and hand instruments (K-file) in the removal of root filling materials. Forty-two extracted single-rooted anterior teeth were selected. The root canals were enlarged with nickel-titanium (NiTi) rotary files, filled with gutta-percha and sealer, and randomly divided into 3 experimental groups. The filling materials were removed with solvent in conjunction with one of the following devices and techniques: the ProTaper Universal System for retreatment, ProFile 0.06, and hand instruments (K-file). The roots were longitudinally sectioned, and the image of the root surface was photographed. The images were captured in JPEG format; the areas of the remaining filling materials and the time required for removing the gutta-percha and sealer were calculated by using the nonparametric one-way Kruskal-Wallis test and Tukey-Kramer tests, respectively. The group that showed better results for removing filling materials was the ProTaper Universal System for retreatment files, whereas the group of ProFile rotary instruments yielded better root canal cleanliness than the hand instruments, even though there was no statistically significant difference. The ProTaper Universal System for retreatment and ProFile rotary instruments worked significantly faster than the K-file. The ProTaper Universal System for retreatment files left cleaner root canal walls than the K-file hand instruments and the ProFile Rotary instruments, although none of the devices used guaranteed complete removal of the filling materials. The rotary NiTi system proved to be faster than hand instruments in removing root filling materials.

  17. RECOMMENDED FOUNDATION FILL MATERIALS CONSTRUCTION STANDARD OF THE FLORIDA RADON RESEARCH PROGRAM

    Science.gov (United States)

    The report summarizes the technical basis for a recommended foundation fill materials standard for new construction houses in Florida. he radon-control construction standard was developed by the Florida Radon Research Program (FRRP). ill material standards are formulated for: (1)...

  18. Setting of loose-fill insulation materials in walls; Saetningsfri indblaesning af loesfyldsisolering i vaegge

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, T.V.

    2001-07-01

    The report describes material behaviour, which significantly influences the settling of loose-fill insulation materials. The specific application presented here is loose-fill insulation material injected in walls as thermal insulation. The physical formulation of the issue to be discussed is that the mass is kept in position in the cavity by frictional forces, which counteracts the settling but complicates injection. The purpose of this study is to investigate whether there is a possibility that decreased friction will be able to release settling. Cellulose loose-fill material injected in a 0.1 m thick and 1 m wide gypsum wall with a minimum density of 48 kg/m3 was found not to settle if kept at a constant relative humidity, RH 50 %. A minimum density of 53 kg/m3 is necessary if the thickness of the wall is increased from 0.1 m to 0.3 m. If changing the constant environment from RH 50 % to RH 80 % a minimum density of 63 kg/m3 is necessary. Furthermore, results so far show that cellulose loose-fill material spread on the attic floor will have a density after settling of 48 kg /M3 for a constant RH 50 %, corresponding to 43 kg/m3 dry material. The results were found by using a model and tests. (au)

  19. The choice of iron-containing filling for composite radioprotective material

    Science.gov (United States)

    Matyukhin, P. V.

    2018-03-01

    The paper presents the data the composition of modern composite building materials including materials which in addition to high physical-mechanical have radio-protective properties. The article presents infrared researches and differential thermal data of fine-grained magnetite and hematite beneficiated iron-ore concentrates. The choice of the most suitable filling for new composite radio-protective building material engineering and development was made basing on the magnetite and hematite data presented in the paper.

  20. Rheology of Emulsion-Filled Gels Applied to the Development of Food Materials

    Directory of Open Access Journals (Sweden)

    Ivana M. Geremias-Andrade

    2016-08-01

    Full Text Available Emulsion-filled gels are classified as soft solid materials and are complex colloids formed by matrices of polymeric gels into which emulsion droplets are incorporated. Several structural aspects of these gels have been studied in the past few years, including their applications in food, which is the focus of this review. Knowledge of the rheological behavior of emulsion-filled gels is extremely important because it can measure interferences promoted by droplets or particle inclusion on the textural properties of the gelled systems. Dynamic oscillatory tests, more specifically, small amplitude oscillatory shear, creep-recovery tests, and large deformation experiments, are discussed in this review as techniques present in the literature to characterize rheological behavior of emulsion-filled gels. Moreover, the correlation of mechanical properties with sensory aspects of emulsion-filled gels appearing in recent studies is discussed, demonstrating the applicability of these parameters in understanding mastication processes.

  1. Construction of a test embankment using a sand-tire shred mixture as fill material.

    Science.gov (United States)

    Yoon, Sungmin; Prezzi, Monica; Siddiki, Nayyar Zia; Kim, Bumjoo

    2006-01-01

    Use of tire shreds in construction projects, such as highway embankments, is becoming an accepted way of beneficially recycling scrap tires. However, in the last decade there was a decline in the use of pure tire shreds as fill materials in embankment construction, as they are susceptible to fire hazards due to the development of exothermic reactions. Tire shred-sand mixtures, on the other hand, were found to be effective in inhibiting exothermic reactions. When compared with pure tire shreds, tire shred-sand mixtures are less compressible and have higher shear strength. However, the literature contains limited information on the use of tire shred-soil mixtures as a fill material. The objectives of this paper are to discuss and evaluate the feasibility of using tire shred-sand mixtures as a fill material in embankment construction. A test embankment constructed using a 50/50 mixture, by volume, of tire shreds and sand was instrumented and monitored to: (a) determine total and differential settlements; (b) evaluate the environmental impact of the embankment construction on the groundwater quality due to leaching of fill material; and (c) study the temperature variation inside the embankment. The findings in this research indicate that mixtures of tire shreds and sand are viable materials for embankment construction.

  2. Cleaning efficacy of reciprocal and rotary systems in the removal of root canal filling material

    Science.gov (United States)

    Koçak, Mustafa Murat; Koçak, Sibel; Türker, Sevinç Aktemur; Sağlam, Baran Can

    2016-01-01

    Aim: The aim of this study was to compare the efficacy of hand file, nickel titanium rotary instrument, and two reciprocating instruments for removing gutta-percha and sealer from the root canals. Materials and Methods: Eighty-eight mandibular premolar teeth were used. The root canals were shaped and filled with gutta-percha and a resin-based sealer. The specimens were divided into four groups according to the technique by which the root filling material was removed: Group 1 — Wave One; Group 2 — Reciproc; Group 3 — ProTaper; and Group 4 — Gates-Glidden burs and stainless steel hand file. Then teeth were split longitudinally and photographed. The images were transferred to a computer. The ratio of remaining filling material to the root canal periphery was calculated with the aid of ImageJ software. Statistical analysis was performed using Kruskal–Wallis and Mann–Whitney tests. Results: A significant difference was found among all groups (P hand file. Conclusion: The reciprocating files were found to be significantly more effective in removing the filling material from the canal walls compared to the rotational file and hand file. PMID:27099429

  3. Push-out bond strength of different tricalcium silicate-based filling materials to root dentin

    Directory of Open Access Journals (Sweden)

    Jorge Henrique Stefaneli Marques

    2018-03-01

    Full Text Available Abstract: The aim of this study was to evaluate the bond strength of different triccalcium silicate cements to retrograde cavity using a push out test. Thirty maxillary central incisors were shaped using #80 hand files and sectioned transversally. Root slices were obtained from the apical 4 mm after eliminating the apical extremity. The specimens were embedded in acrylic resin and positioned at 45° to the horizontal plane for preparation of root-end cavities with a diamond ultrasonic retrotip. The samples were divided into three groups according to the root-end filling material (n = 10: MTA Angelus, ProRoot MTA and Biodentine. A gutta-percha cone (#80 was tugged-back at the limit between the canal and the root-end cavity. The root-end cavity was filled and the gutta-percha cone was removed after complete setting of the materials. The specimens were placed in an Instron machine with the root-end filling turned downwards. The push-out shaft was inserted in the space previously occupied by the gutta-percha cone and push out testing was performed at a crosshead speed of 1.0 mm/min. There was no statistically significant difference in resistance to push out by the materials tested (p > 0.01. MTA Angelus and ProRoot MTA showed predominantly mixed failure while Biodentine exhibited mixed and cohesive failures. The tricalcium silicate-based root-end filling materials showed similar bond strength retrograde cavity.

  4. Push-out bond strength of different tricalcium silicate-based filling materials to root dentin.

    Science.gov (United States)

    Stefaneli Marques, Jorge Henrique; Silva-Sousa, Yara Teresinha Corrêa; Rached-Júnior, Fuad Jacob Abi; Macedo, Luciana Martins Domingues de; Mazzi-Chaves, Jardel Francisco; Camilleri, Josette; Sousa-Neto, Manoel Damião

    2018-03-08

    The aim of this study was to evaluate the bond strength of different triccalcium silicate cements to retrograde cavity using a push out test. Thirty maxillary central incisors were shaped using #80 hand files and sectioned transversally. Root slices were obtained from the apical 4 mm after eliminating the apical extremity. The specimens were embedded in acrylic resin and positioned at 45° to the horizontal plane for preparation of root-end cavities with a diamond ultrasonic retrotip. The samples were divided into three groups according to the root-end filling material (n = 10): MTA Angelus, ProRoot MTA and Biodentine. A gutta-percha cone (#80) was tugged-back at the limit between the canal and the root-end cavity. The root-end cavity was filled and the gutta-percha cone was removed after complete setting of the materials. The specimens were placed in an Instron machine with the root-end filling turned downwards. The push-out shaft was inserted in the space previously occupied by the gutta-percha cone and push out testing was performed at a crosshead speed of 1.0 mm/min. There was no statistically significant difference in resistance to push out by the materials tested (p > 0.01). MTA Angelus and ProRoot MTA showed predominantly mixed failure while Biodentine exhibited mixed and cohesive failures. The tricalcium silicate-based root-end filling materials showed similar bond strength retrograde cavity.

  5. Dental Glass Ionomer Cements as Permanent Filling Materials? – Properties, Limitations and Future Trends

    Directory of Open Access Journals (Sweden)

    Ulrich Lohbauer

    2009-12-01

    Full Text Available Glass ionomer cements (GICs are clinically attractive dental materials that have certain unique properties that make them useful as restorative and luting materials. This includes adhesion to moist tooth structures and base metals, anticariogenic properties due to release of fluoride, thermal compatibility with tooth enamel, biocompatibility and low toxicity. The use of GICs in a mechanically loaded situation, however, has been hampered by their low mechanical performance. Poor mechanical properties, such as low fracture strength, toughness and wear, limit their extensive use in dentistry as a filling material in stress-bearing applications. In the posterior dental region, glass ionomer cements are mostly used as a temporary filling material. The requirement to strengthen those cements has lead to an ever increasing research effort into reinforcement or strengthening concepts.

  6. Characteristics of novel root-end filling material using epoxy resin and Portland cement.

    Science.gov (United States)

    Lee, Sang-Jin; Chung, Jin; Na, Hee-Sam; Park, Eun-Joo; Jeon, Hyo-Jin; Kim, Hyeon-Cheol

    2013-04-01

    The aim of this study was to evaluate the physical properties and cytotoxicity of a novel root-end filling material (EPC) which is made from epoxy resin and Portland cement as a mineral trioxide aggregate (MTA) substitute. EPC, developed as a root-end filling material, was compared with MTA and a mixture of AH Plus sealer and MTA (AMTA) with regard to the setting time, radio-opacity, and microleakage. Setting times were evaluated using Vicat apparatus. Digital radiographs were taken to evaluate the aluminium equivalent radio-opacity using an aluminium step wedge. Extracted single-rooted teeth were used for leakage test using methylene blue dye. After canal shaping and obturation, the apical 3-mm root was resected, and a root-end cavity with a depth of 3 mm was prepared. The root-end cavities were filled with MTA, AMTA, and EPC for 15 specimens in each of three groups. After setting in humid conditions for 24 h, the specimens were tested for apical leakage. For evaluation of the biocompatibility of EPC, cell (human gingival fibroblast) viability was compared for MTA and Portland cement by MTT assay, and cell morphological changes were compared for MTA and AH Plus by fluorescence microscopy using DAPI and F-actin staining. The setting time, radio-opacity, and microleakage were compared using one-way ANOVA and Scheffe's post hoc comparison, and the cytotoxicity was compared using the nonparametric Kruskal-Wallis rank sum test. Statistical significance was set at 95%. EPC had a shorter setting time and less microleakage compared with MTA (p Portland cement, was found to be a useful material for root-end filling, with favourable radio-opacity, short setting time, low microleakage, and clinically acceptable low cytotoxicity. The novel root-end filling material would be a potentially useful material for a surgical endodontic procedure with favourable properties.

  7. Thermal properties of lauric acid filled in carbon nanotubes as shape-stabilized phase change materials.

    Science.gov (United States)

    Feng, Yanhui; Wei, Runzhi; Huang, Zhi; Zhang, Xinxin; Wang, Ge

    2018-03-14

    Carbon nanotubes (CNTs) filled with lauric acid (LA) as a kind of shape-stabilized phase change material were prepared and their structures and phase change properties were characterized. The results showed that the melting point and latent heat of LA confined in carbon nanotubes were lower than those of the bulk material, and both decrease as the diameters of CNTs and the filling ratios of LA decrease. Molecular dynamics (MD) simulations indicated that LA molecules form a liquid layer near pore walls and crystallize at the pore center. When the LA filling ratio was reduced to a certain value, all LA molecules were attached to the inner walls of CNTs, hindering their crystallization. A linear relationship between the melting temperature shift and structural properties was obtained based on the modified Gibbs-Thomson equation, which gives a reliable interpretation of the size effect of nanochannels in phase change materials. We also found that the thermal conductivity of the composite CNTs/LA was four times larger than that of pure LA. This study will provide insights into the design of novel composite phase change materials with better thermal properties by the selection of suitable porous materials and tailoring their pore structures.

  8. Experimental Study and Application of Inorganic Solidified Foam Filling Material for Coal Mines

    Directory of Open Access Journals (Sweden)

    Hu Wen

    2017-01-01

    Full Text Available Spontaneous combustion of residual coal in a gob due to air leakage poses a major risk to mining safety. Building an airtight wall is an effective measure for controlling air leakage. A new type of inorganic solidified foam-filled material was developed and its physical and chemical properties were analyzed experimentally. The compressive strength of this material increased with the amount of sulphoaluminate cement. With an increasing water–cement ratio, the initial setting time was gradually extended while the final setting time firstly shortened and then extended. The change in compressive strength had the opposite tendency. Additionally, as the foam expansion ratio increased, the solidification time tended to decrease but the compressive strength remained approximately constant. With an increase in foam production, the solidification time increased and the compressive strength decreased exponentially. The results can be used to determine the optimal material ratios of inorganic solidified foam-filled material for coal mines, and filling technology for an airtight wall was designed. A field application of the new material demonstrated that it seals crossheadings tightly, leaves no fissures, suppresses air leakage to the gob, and narrows the width of the spontaneous combustion and heat accumulation zone.

  9. Shear bond strength of bulk-fill and nano-restorative materials to dentin.

    Science.gov (United States)

    Colak, Hakan; Ercan, Ertugrul; Hamidi, Mehmet Mustafa

    2016-01-01

    Bulk-fill composite materials are being developed for preparation depths of up to 4 mm in an effort to simplify and improve the placement of direct composite posterior restorations. The aim of our study was to compare shear-bond strength of bulk-fill and conventional posterior composite resins. In this study, 60 caries free extracted human molars were used and sectioned parallel to occlusal surface to expose midcoronal dentin. The specimens were randomly divided into four groups. Total-etch dentine bonding system (Adper Scotchbond 1XT, 3M ESPE) was applied to dentin surface in all the groups to reduce variability in results. Then, dentine surfaces covered by following materials. Group I: SonicFill Bulk-Fill, Group II: Tetric EvoCeram (TBF), Group III: Herculite XRV Ultra, and Group IV: TBF Bulk-Fill, 2 mm × 3 mm cylindrical restorations were prepared by using application apparatus. Shear bond testing was measured by using a universal testing machine. Kruskal-Wallis and Mann-Whitney U-tests were performed to evaluate the data. The highest value was observed in Group III (14.42 ± 4.34) and the lowest value was observed in Group IV (11.16 ± 2.76) and there is a statistically significant difference between these groups (P = 0.046). However, there is no statistically significant difference between the values of other groups. In this study, Group III was showed higher strength values. There is a need for future studies about long-term bond strength and clinical success of these adhesive and bulk-fill systems.

  10. Comparison of Endoflas and Zinc oxide Eugenol as root canal filling materials in primary dentition

    Directory of Open Access Journals (Sweden)

    Nivedita Rewal

    2014-01-01

    Full Text Available Background: Zinc oxide eugenol has long been the material of choice of pediatric dentists worldwide, although it fails to meet the ideal requirements of root canal filling material for primary teeth. Endoflas, a mixture of zinc oxide eugenol, calcium hydroxide, and iodoform, can be considered to be an effective root canal filling material in primary teeth as compared with zinc oxide eugenol. This study was carried out to compare zinc oxide eugenol with endoflas for pulpectomy in primary dentition. Aim: The objective of the study was to compare clinically and radiographically success rates of zinc oxide eugenol with endoflas for the root canal filling of primary teeth at 3, 6, and 9 months. Design: Fifty primary molars were included in the study with 26 teeth in Group I (Endoflas and 24 in Group II (zinc oxide eugenol. A single visit pulpectomy was carried out. Results: The overall success rate of zinc oxide eugenol was 83% whereas 100% success was found in the case of endoflas. The obtained results were compiled and subjected to statistical analysis using the chi-square test. The difference in the success rate between the two was statistically significant (P < 0.05. Conclusion: Endoflas has shown to have better results than zinc oxide eugenol. It should therefore be the material of choice for root canal treatment in deciduous dentition.

  11. Air-Filled Nanopore Based High-Performance Thermal Insulation Materials

    OpenAIRE

    Gangåssæter, Haakon Fossen; Jelle, Bjørn Petter; Alex Mofid, Sohrab; Gao, Tao

    2017-01-01

    State-of-the-art thermal insulation solutions like vacuum insulation panels (VIP) and aerogels have low thermal conductivity, but their drawbacks may make them unable to be the thermal insulation solutions that will revolutionize the building industry regarding energy-efficient building envelopes. Nevertheless, learning from these materials may be crucial to make new and novel high-performance thermal insulation products. This study presents a review on the state-of-the-art air-filled thermal...

  12. Effect of bulk-fill base material on fracture strength of root-filled teeth restored with laminate resin composite restorations.

    Science.gov (United States)

    Taha, N A; Maghaireh, G A; Ghannam, A S; Palamara, J E

    2017-08-01

    To evaluate the effect of using a bulk-fill flowable base material on fracture strength and fracture patterns of root-filled maxillary premolars with MOD preparations restored with laminate restorations. Fifty extracted maxillary premolars were selected for the study. Standardized MOD cavities with endodontic treatment were prepared for all teeth, except for intact control. The teeth were divided randomly into five groups (n=10); (Group 1) sound teeth, (Group 2) unrestored teeth; (Group 3) MOD cavities with Vitrebond base and resin-based composite (Ceram. X One Universal); (Group 4) MOD cavities with 2mm GIC base (Fuji IX GP) and resin-based composite (Ceram. X One Universal) open laminate, (Group 5) MOD cavities were restored with 4mm of bulk-fill flowable base material (SDR) and resin-based composite (Ceram. X One Universal). All teeth were thermocycled and subjected to a 45° ramped oblique load in a universal testing machine. Fracture load and fracture patterns were recorded. Data were analyzed using one-way ANOVA and Dunnett's T3 test. Restoration in general increased the fracture strength compared to unrestored teeth. The fracture strength of group 5 (bulk-fill) was significantly higher than the fracture strength of the GIC laminate groups and not significantly different from the intact teeth (355±112N, P=0.118). The type of failure was unfavorable for most of the groups, with the majority being mixed failures. The use of a bulk-fill flowable base material significantly increased the fracture strength of extracted root-filled teeth with MOD cavities; however it did not improve fracture patterns to more favorable ones. Investigating restorative techniques that may improve the longevity of root-filled premolar teeth restored with direct resin restorations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Development of a novel filling technique. Loading bulk particulate materials into tankers or processes

    Energy Technology Data Exchange (ETDEWEB)

    Farnish, R.J.; Berry, R.; Bradley, M. [Greenwich Univ., Chatham Maritime, Kent (United Kingdom). Wolfson Centre for Bulk Solids Handling Technology

    2008-07-01

    The majority of industrial dosing or filling operations demand high filling rates and often good repeatability of discharges. For coarse, free-flowing materials the issues of obtaining a high degree of filling efficiency are substantially less challenging than for less free-flowing or cohesive bulk particulates. Typical equipment arrangements for achieving a controlled (often dual rate) discharge of particles into a relatively small capacity container (flask, sack or big bag) often rely on either a mechanical extraction of material from a buffer (screw feeders) or the manipulation of a constricting arrangement to achieve a turn down in discharge rate. Where less freeflowing or very fine particles are being handled, the introduction of air into the powder is invariably used to modify the bulk condition of the material to a condition where discharge can be initiated and supported (typical examples being powder feed to an impeller packer, or discharge of powder into a rail or road wagon). This article will therefore report on some recent research that has been undertaken by The Wolfson Centre for Bulk Solids Handling Technology, University of Greenwich. (orig.)

  14. Dark localized structures in a cavity filled with a left-handed material

    International Nuclear Information System (INIS)

    Tlidi, Mustapha; Kockaert, Pascal; Gelens, Lendert

    2011-01-01

    We consider a nonlinear passive optical cavity filled with left-handed and right-handed materials and driven by a coherent injected beam. We assume that both left-handed and right-handed materials possess a Kerr focusing type of nonlinearity. We show that close to the zero-diffraction regime, high-order diffraction allows us to stabilize dark localized structures in this device. These structures consist of dips in the transverse profile of the intracavity field and do not exist without high-order diffraction. We analyze the snaking bifurcation diagram associated with these structures. Finally, a realistic estimation of the model parameters is provided.

  15. Soft Chemistry, Coloring and Polytypism in Filled Tetrahedral Semiconductors: Toward Enhanced Thermoelectric and Battery Materials.

    Science.gov (United States)

    White, Miles A; Medina-Gonzalez, Alan M; Vela, Javier

    2018-03-12

    Filled tetrahedral semiconductors are a rich family of compounds with tunable electronic structure, making them ideal for applications in thermoelectrics, photovoltaics, and battery anodes. Furthermore, these materials crystallize in a plethora of related structures that are very close in energy, giving rise to polytypism through the manipulation of synthetic parameters. This Minireview highlights recent advances in the solution-phase synthesis and nanostructuring of these materials. These methods enable the synthesis of metastable phases and polytypes that were previously unobtainable. Additionally, samples synthesized in solution phase have enhanced thermoelectric performance due to their decreased grain size. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Retention of uranium(VI) by laumontite, a fracture-filling material of granite

    International Nuclear Information System (INIS)

    Baik, M.H.; Lee, S.Y.; Shon, W.J.

    2009-01-01

    Retention of U(VI) by laumontite, a fracture-filling material of granite as investigated by conducting dynamic and batch sorption experiments in a love-box using a granite core with a natural fracture. The hydrodynamic properties of the granite core were obtained from the elution curve of a on-sorbing tracer, Br - . The elution curve of U(VI) showed a similar behavior to Br - . This reveals that the retention of U(VI) by the fracture-filling material was not significant when migrating through the fracture at a given condition. From the dynamic sorption experiment, the retardation factor R a and the distribution coefficient K a of U(VI) were obtained as about 2.9 and 0.16 cm, respectively. The distribution coefficient K d ) of U(VI) onto laumontite obtained by conducting a batch sorption experiment resulted in a small value of 2.3±0.5 mL/g. This low K d value greed with the result of the dynamic sorption experiment. For the distribution of uranium on the granite surface investigated by an X-ray image mapping, the fracture region filled with laumontite showed a relatively lower content of uranium compared to the surrounding granite surface. Thus, the low retention of U(VI) by the fracture-filling material can be explained by following two mechanisms. One is that U(VI) exists as anionic uranyl hydroxides or uranyl carbonates at a given groundwater condition and the other is the remarkably low sorption capacity of the laumontite for U(VI). author)

  17. Microstructure and wettability of root canal dentine and root canal filling materials after different chemical irrigation

    Energy Technology Data Exchange (ETDEWEB)

    Antonijevic, Djordje; Milovanovic, Petar [Laboratory for Anthropology, Institute for Anatomy, Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Brajkovic, Denis [Department of Dentistry, Faculty of Medical Sciences, University of Kragujevac, Kragujevac (Serbia); Ilic, Dragan [Department of Restorative Medicine, School of Dental Medicine, University of Belgrade, Belgrade (Serbia); Hahn, Michael; Amling, Michael [Department of Osteology and Biomechanics (IOBM), University Medical Center Hamburg-Eppendorf, Lottestr. 55A, 22529 Hamburg (Germany); Rakocevic, Zlatko [Laboratory for Atomic Physics, Institute for Nuclear Science “Vinca”, University of Belgrade, Belgrade (Serbia); Djuric, Marija [Laboratory for Anthropology, Institute for Anatomy, Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Busse, Björn, E-mail: b.busse@uke.uni-hamburg.de [Department of Osteology and Biomechanics (IOBM), University Medical Center Hamburg-Eppendorf, Lottestr. 55A, 22529 Hamburg (Germany)

    2015-11-15

    Graphical abstract: - Highlights: • Different irrigation solutions and disinfectants were used for treatment of root canal dentine and gutta-percha points. • Materials surface characteristics were assessed using quantitative backscattered electron imaging, reference point indentation, and contact angle analyzer. • The most significant differences in mineralization, indentation, and adhesive outcomes were observed after ethylenediaminetetraacetic acid treatment. • Irrigation solutions confer to superior sealing ability of endodontic filling materials. • Micromechanical characteristics of dentine after irrigation are considerable reduced. - Abstract: The objective of this study was to determine the effects of various irrigation solutions on root canal dentine and gutta-percha surface properties. In addition, the effects of disinfectant chemicals on the wettability and surface morphological properties of the filling materials were evaluated. Ethylenediaminetetraacetic acid (EDTA), citric acid, and ozone were employed as irrigation solutions for dentine and gutta-percha treatment. Thereafter, the samples’ microstructure, degree of mineralization, and mechanical properties were assessed by means of quantitative backscattered electron imaging (qBEI) and reference point indentation (RPI). A contact angle analyzer was used to measure adhesion on the tested materials. Here, EDTA had the most significant affect on both the mechanical properties and the adhesive behavior of dentine. Citric acid did not affect dentine wettability, whereas the indentation properties and the mineralization were reduced. Similar effects were observed when ozone was used. The dentinal tubules were significantly widened in citric acid compared to the ozone group. EDTA causes considerable micromechanical surface alteration of dentine and gutta-percha, but represents the best option in clinical cases where a high adhesiveness of the filling materials is desired.

  18. Hybrid waste filler filled bio-polymer foam composites for sound absorbent materials

    Science.gov (United States)

    Rus, Anika Zafiah M.; Azahari, M. Shafiq M.; Kormin, Shaharuddin; Soon, Leong Bong; Zaliran, M. Taufiq; Ahraz Sadrina M. F., L.

    2017-09-01

    Sound absorption materials are one of the major requirements in many industries with regards to the sound insulation developed should be efficient to reduce sound. This is also important to contribute in economically ways of producing sound absorbing materials which is cheaper and user friendly. Thus, in this research, the sound absorbent properties of bio-polymer foam filled with hybrid fillers of wood dust and waste tire rubber has been investigated. Waste cooking oil from crisp industries was converted into bio-monomer, filled with different proportion ratio of fillers and fabricated into bio-polymer foam composite. Two fabrication methods is applied which is the Close Mold Method (CMM) and Open Mold Method (OMM). A total of four bio-polymer foam composite samples were produce for each method used. The percentage of hybrid fillers; mixture of wood dust and waste tire rubber of 2.5 %, 5.0%, 7.5% and 10% weight to weight ration with bio-monomer. The sound absorption of the bio-polymer foam composites samples were tested by using the impedance tube test according to the ASTM E-1050 and Scanning Electron Microscope to determine the morphology and porosity of the samples. The sound absorption coefficient (α) at different frequency range revealed that the polymer foam of 10.0 % hybrid fillers shows highest α of 0.963. The highest hybrid filler loading contributing to smallest pore sizes but highest interconnected pores. This also revealed that when highly porous material is exposed to incident sound waves, the air molecules at the surface of the material and within the pores of the material are forced to vibrate and loses some of their original energy. This is concluded that the suitability of bio-polymer foam filled with hybrid fillers to be used in acoustic application of automotive components such as dashboards, door panels, cushion and etc.

  19. Microstructure and wettability of root canal dentine and root canal filling materials after different chemical irrigation

    International Nuclear Information System (INIS)

    Antonijevic, Djordje; Milovanovic, Petar; Brajkovic, Denis; Ilic, Dragan; Hahn, Michael; Amling, Michael; Rakocevic, Zlatko; Djuric, Marija; Busse, Björn

    2015-01-01

    Graphical abstract: - Highlights: • Different irrigation solutions and disinfectants were used for treatment of root canal dentine and gutta-percha points. • Materials surface characteristics were assessed using quantitative backscattered electron imaging, reference point indentation, and contact angle analyzer. • The most significant differences in mineralization, indentation, and adhesive outcomes were observed after ethylenediaminetetraacetic acid treatment. • Irrigation solutions confer to superior sealing ability of endodontic filling materials. • Micromechanical characteristics of dentine after irrigation are considerable reduced. - Abstract: The objective of this study was to determine the effects of various irrigation solutions on root canal dentine and gutta-percha surface properties. In addition, the effects of disinfectant chemicals on the wettability and surface morphological properties of the filling materials were evaluated. Ethylenediaminetetraacetic acid (EDTA), citric acid, and ozone were employed as irrigation solutions for dentine and gutta-percha treatment. Thereafter, the samples’ microstructure, degree of mineralization, and mechanical properties were assessed by means of quantitative backscattered electron imaging (qBEI) and reference point indentation (RPI). A contact angle analyzer was used to measure adhesion on the tested materials. Here, EDTA had the most significant affect on both the mechanical properties and the adhesive behavior of dentine. Citric acid did not affect dentine wettability, whereas the indentation properties and the mineralization were reduced. Similar effects were observed when ozone was used. The dentinal tubules were significantly widened in citric acid compared to the ozone group. EDTA causes considerable micromechanical surface alteration of dentine and gutta-percha, but represents the best option in clinical cases where a high adhesiveness of the filling materials is desired.

  20. Discrimination of high-Z materials in concrete-filled containers using muon scattering tomography

    Science.gov (United States)

    Frazão, L.; Velthuis, J.; Thomay, C.; Steer, C.

    2016-07-01

    An analysis method of identifying materials using muon scattering tomography is presented, which uses previous knowledge of the position of high-Z objects inside a container and distinguishes them from similar materials. In particular, simulations were performed in order to distinguish a block of Uranium from blocks of Lead and Tungsten of the same size, inside a concrete-filled drum. The results show that, knowing the shape and position from previous analysis, it is possible to distinguish 5 × 5 × 5 cm3 blocks of these materials with about 4h of muon exposure, down to 2 × 2 × 2 cm3 blocks with 70h of data using multivariate analysis (MVA). MVA uses several variables, but it does not benefit the discrimination over a simpler method using only the scatter angles. This indicates that the majority of discrimination is provided by the angular information. Momentum information is shown to provide no benefits in material discrimination.

  1. Reactive transport of Sr, Cs and Tc through a column packed with fracture-filling material

    International Nuclear Information System (INIS)

    Cui, D.; Eriksen, T.

    1998-01-01

    The migration behaviour of the fission products 90 Sr, 137 Cs and 99 Tc in a granite fracture-groundwater system was studied in column experiments using crushed Stripa granite fracture-filling material (125-250 μm) as a sorbent. Based on breakthrough curves of Sr 2+ , Cs + , TcO 4 - and anthraquinonsulphonate, the distribution ratio K d (cm 3 /g) values for Sr 2+ and Cs + were estimated to be 1.5 and 2 respectively; non-sorbing behaviour of TcO 4 - under oxic conditions was observed. The diffusion of Sr 2+ in the material is shown to be a kinetic-controlling step in the desorption process that followed the initial leaching. Under reducing conditions, it was found that TcO 4 - was reduced to TcO 2 .nH 2 O(s) by the Fe(II)-containing fracture-filling material and Tc(IV) aq was rapidly sorbed by the material. This observation proves that the migration of technetium under reducing conditions in deep groundwater systems will not only be controlled by the solubility of TcO 2 . nH 2 O(s) and the speed of groundwater flow but also by the rapid sorption of Tc(IV) aq on all available mineral surfaces. (orig.)

  2. Opportunities of influence of plasma streams formed in IKA with continuos nor king gas filling en the surface of materials

    International Nuclear Information System (INIS)

    Useinov, B.M.; Useinova, A.M.; Amrenova, A.U.; Pusankov, S.A.; Sartin, S.A.; Virko, P.G.

    2001-01-01

    The results of the investigation of influence of plasma stream formed in IKA with continuous working gas filling on the surface of stainless steel 12X18H10T and aluminum are given in this article. It is shown here that the effect of influence of plasma stream on the surface of materials depends on the way of working gas filling. There is the comparison of influence of plasma stream formed in plasma accelerator with impulse and continuous working gas filling

  3. Filling the gaps in SCWR materials research: advanced nuclear corrosion research facilities in Hamilton

    International Nuclear Information System (INIS)

    Krausher, J.L.; Zheng, W.; Li, J.; Guzonas, D.; Botton, G.

    2011-01-01

    Research efforts on materials selection and development in support of the design of supercritical water-cooled reactors (SCWRs) have produced a considerable amount of data on corrosion, creep and other related properties. Summaries of the data on corrosion [1] and stress corrosion cracking [2] have recently been produced. As research on the SCWR advances, gaps and limitations in the published data are being identified. In terms of corrosion properties, these gaps can be seen in several areas, including: 1) the test environment, 2) the physical and chemical severity of the tests conducted as compared with likely reactor service/operating conditions, and 3) the test methods used. While some of these gaps can be filled readily using existing facilities, others require the availability of advanced test facilities for specific tests and assessments. In this paper, highlights of the new materials research facilities jointly established in Hamilton by CANMET Materials Technology Laboratory and McMaster University are presented. (author)

  4. Development and Sliding Wear Response of Epoxy Composites Filled with Coal Mine Overburden Material

    Science.gov (United States)

    Das, Prithika; Satapathy, Alok; Mishra, M. K.

    2018-03-01

    The paper reports on development and characterization of epoxy based composites filled with micro-sized mine overburden material. Coal mine overburden material is typically highly heterogeneous and is considered as waste material. For excavating each ton of coal, roughly 5 tons of overburden materials are removed and is dumped nearby occupying large space. Gainful utilization of this waste is a major challenge. In the present work, this material is used as filler materials in making a new class of epoxy matrix composites. Composites with different weight proportions of fillers (0, 10, 20, 30 and 40) wt. % are prepared by hand layup technique. Compression tests are performed as per corresponding ASTM standards to assess the compressive strength of these composites. Further, dry sliding tests are performed following ASTM G99 standards using a pin on disk machine. A design of experiment approach based on Taguchi’s L16 orthogonal arrays is adopted. Tests are performed at different sliding velocities for multiple sliding distances under varying normal loads. Specific wear rates of the composites under different test conditions are obtained. The analysis of the test results revealed that the filler content and the sliding velocity are the most predominant control factors affecting the wear rate. This work thus, opens up a new avenue for the value added utilization of coal mine overburden material.

  5. Ex vivo evaluation of coronal and apical microbial leakage of root canal - Filled with gutta-percha or Resilon/Epiphany root canal filling material

    Directory of Open Access Journals (Sweden)

    de Almeida-Gomes Fabio

    2010-01-01

    Full Text Available Objective: This ex vivo study compared coronal and apical microleakage of root canals filled with Resilon/Epiphany (RE or gutta-percha/Grossman sealer (GP, using either lateral condensation (LC or System B (SB technique. Materials and Methods: Specimens in eight experimental groups were obturated using the following materials and techniques: Groups 1 and 3 - GP and LC; groups 2 and 4 - GP and SB; groups 5 and 7 - RE and LC; groups 6 and 8 - RE and SB. Apical and coronal leakages were tested using bacterial methods. For coronal analysis, the number of days required for complete contamination of the root canals was recorded according to observation of the brain heart infusion broth turbidity for 15 weeks. For apical analysis, the teeth were cleaved and the leakage was measured at 30 days. Data were collected for each sample and analyzed statistically with the Chi-square and ANOVA tests. Results: Leakage was found in all groups. The difference between filling materials, obturation techniques, and median time of leakage was not statistically significant for coronal ( P=0.847 and apical ( P=0.5789 leakages. Conclusion: There were no differences between the different filling materials (gutta-percha/Grossman sealer and Resilon/Epiphany and obturation techniques (lateral condensation and system B technique in coronal or apical leakages.

  6. Adjustable Polyurethane Foam as Filling Material for a Novel Spondyloplasty: Biomechanics and Biocompatibility.

    Science.gov (United States)

    Jiang, Hongzhen; Sitoci-Ficici, Kerim Hakan; Reinshagen, Clemens; Molcanyi, Marek; Zivcak, Jozef; Hudak, Radovan; Laube, Thorsten; Schnabelrauch, Matthias; Weisser, Jürgen; Schäfer, Ute; Pinzer, Thomas; Schackert, Gabriele; Zhang, Xifeng; Wähler, Mario; Brautferger, Uta; Rieger, Bernhard

    2018-04-01

    To investigate the biomechanics and biocompatibility of polyurethane (PU) foam with adjustable stiffness as a filling material for a novel spondyloplasty that is designed to reduce the risk of postoperative adjacent level fractures. Sixty individual porcine lumbar vertebrae were randomly split into 4 groups: A, B, C, and D. Group A served as unmodified vertebral body controls. Groups B, C, and D consisted of hollowed vertebral bodies. Vertebrae of groups C and D were filled with adjustable PU foams of different stiffness. The compressive strength and stiffness of vertebrae from groups A-D were recorded and analyzed. 3T3 mouse fibroblasts were cultured with preformed PU foams for 4 days to test biocompatibility. The strength and stiffness of the hollowed groups were lower than in group A. However, the differences were not statistically significant between group A and group C (P > 0.05), and were obviously different between group A and group B or group D (P < 0.01 and <0.05, respectively). Moreover, the strength and stiffness after filling foams in group C or group D were significantly greater than in group B (P < 0.01 and <0.05, respectively). Live/dead staining of 3T3 cells confirmed the biocompatibility of the PU foam. The new PU foam shows adaptability regarding its stiffness and excellent cytocompatibility in vitro. The results support the clinical translation of the new PU foams as augmentation material in the development of a novel spondyloplasty. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Tanks 18 And 19-F Structural Flowable Grout Fill Material Evaluation And Recommendations

    International Nuclear Information System (INIS)

    Langton, C. A.; Stefanko, D. B.

    2013-01-01

    Cementitious grout will be used to close Tanks 18-F and 19-F. The functions of the grout are to: 1) physically stabilize the final landfill by filling the empty volume in the tanks with a non-compressible material; 2) provide a barrier for inadvertent intrusion into the tank; 3) reduce contaminant mobility by a) limiting the hydraulic conductivity of the closed tank and b) reducing contact between the residual waste and infiltrating water; and 4) providing an alkaline, chemically reducing environment in the closed tank to control speciation and solubility of selected radionuclides. The objective of this work was to identify a single (all-in-one) grout to stabilize and isolate the residual radionuclides in the tank, provide structural stability of the closed tank and serve as an inadvertent intruder barrier. This work was requested by V. A. Chander, High Level Waste (HLW) Tank Engineering, in HLW-TTR-2011-008. The complete task scope is provided in the Task Technical and QA Plan, SRNL-RP-2011-00587 Revision 0. The specific objectives of this task were to: 1) Identify new admixtures and dosages for formulating a zero bleed flowable tank fill material selected by HLW Tank Closure Project personnel based on earlier tank fill studies performed in 2007. The chemical admixtures used for adjusting the flow properties needed to be updated because the original admixture products are no longer available. Also, the sources of cement and fly ash have changed, and Portland cements currently available contain up to 5 wt. % limestone (calcium carbonate). 2) Prepare and evaluate the placement, compressive strength, and thermal properties of the selected formulation with new admixture dosages. 3) Identify opportunities for improving the mix selected by HLW Closure Project personnel and prepare and evaluate two potentially improved zero bleed flowable fill design concepts; one based on the reactor fill grout and the other based on a shrinkage compensating flowable fill mix design. 4

  8. Tanks 18 And 19-F Structural Flowable Grout Fill Material Evaluation And Recommendations

    International Nuclear Information System (INIS)

    Stefanko, D.; Langton, C.

    2011-01-01

    Cementitious grout will be used to close Tanks 18-F and 19-F. The functions of the grout are to: (1) physically stabilize the final landfill by filling the empty volume in the tanks with a non compressible material; (2) provide a barrier for inadvertent intrusion into the tank; (3) reduce contaminant mobility by (a) limiting the hydraulic conductivity of the closed tank and (b) reducing contact between the residual waste and infiltrating water; and (4) providing an alkaline, chemically reducing environment in the closed tank to control speciation and solubility of selected radionuclides. The objective of this work was to identify a single (all-in-one) grout to stabilize and isolate the residual radionuclides in the tank, provide structural stability of the closed tank and serve as an inadvertent intruder barrier. This work was requested by V. A. Chander, High Level Waste (HLW) Tank Engineering, in HLW-TTR-2011-008. The complete task scope is provided in the Task Technical and QA Plan, SRNL-RP-2011-00587 Revision 0. The specific objectives of this task were to: (1) Identify new admixtures and dosages for formulating a zero bleed flowable tank fill material selected by HLW Tank Closure Project personnel based on earlier tank fill studies performed in 2007. The chemical admixtures used for adjusting the flow properties needed to be updated because the original admixture products are no longer available. Also, the sources of cement and fly ash have changed, and Portland cements currently available contain up to 5 wt. % limestone (calcium carbonate). (2) Prepare and evaluate the placement, compressive strength, and thermal properties of the selected formulation with new admixture dosages. (3) Identify opportunities for improving the mix selected by HLW Closure Project personnel and prepare and evaluate two potentially improved zero bleed flowable fill design concepts; one based on the reactor fill grout and the other based on a shrinkage compensating flowable fill mix

  9. Tanks 18 And 19-F Structural Flowable Grout Fill Material Evaluation And Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Langton, C. A.; Stefanko, D. B.

    2013-04-23

    Cementitious grout will be used to close Tanks 18-F and 19-F. The functions of the grout are to: 1) physically stabilize the final landfill by filling the empty volume in the tanks with a non-compressible material; 2) provide a barrier for inadvertent intrusion into the tank; 3) reduce contaminant mobility by a) limiting the hydraulic conductivity of the closed tank and b) reducing contact between the residual waste and infiltrating water; and 4) providing an alkaline, chemically reducing environment in the closed tank to control speciation and solubility of selected radionuclides. The objective of this work was to identify a single (all-in-one) grout to stabilize and isolate the residual radionuclides in the tank, provide structural stability of the closed tank and serve as an inadvertent intruder barrier. This work was requested by V. A. Chander, High Level Waste (HLW) Tank Engineering, in HLW-TTR-2011-008. The complete task scope is provided in the Task Technical and QA Plan, SRNL-RP-2011-00587 Revision 0. The specific objectives of this task were to: 1) Identify new admixtures and dosages for formulating a zero bleed flowable tank fill material selected by HLW Tank Closure Project personnel based on earlier tank fill studies performed in 2007. The chemical admixtures used for adjusting the flow properties needed to be updated because the original admixture products are no longer available. Also, the sources of cement and fly ash have changed, and Portland cements currently available contain up to 5 wt. % limestone (calcium carbonate). 2) Prepare and evaluate the placement, compressive strength, and thermal properties of the selected formulation with new admixture dosages. 3) Identify opportunities for improving the mix selected by HLW Closure Project personnel and prepare and evaluate two potentially improved zero bleed flowable fill design concepts; one based on the reactor fill grout and the other based on a shrinkage compensating flowable fill mix design. 4

  10. TANKS 18 AND 19-F STRUCTURAL FLOWABLE GROUT FILL MATERIAL EVALUATION AND RECOMMENDATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Stefanko, D.; Langton, C.

    2011-11-01

    Cementitious grout will be used to close Tanks 18-F and 19-F. The functions of the grout are to: (1) physically stabilize the final landfill by filling the empty volume in the tanks with a non compressible material; (2) provide a barrier for inadvertent intrusion into the tank; (3) reduce contaminant mobility by (a) limiting the hydraulic conductivity of the closed tank and (b) reducing contact between the residual waste and infiltrating water; and (4) providing an alkaline, chemically reducing environment in the closed tank to control speciation and solubility of selected radionuclides. The objective of this work was to identify a single (all-in-one) grout to stabilize and isolate the residual radionuclides in the tank, provide structural stability of the closed tank and serve as an inadvertent intruder barrier. This work was requested by V. A. Chander, High Level Waste (HLW) Tank Engineering, in HLW-TTR-2011-008. The complete task scope is provided in the Task Technical and QA Plan, SRNL-RP-2011-00587 Revision 0. The specific objectives of this task were to: (1) Identify new admixtures and dosages for formulating a zero bleed flowable tank fill material selected by HLW Tank Closure Project personnel based on earlier tank fill studies performed in 2007. The chemical admixtures used for adjusting the flow properties needed to be updated because the original admixture products are no longer available. Also, the sources of cement and fly ash have changed, and Portland cements currently available contain up to 5 wt. % limestone (calcium carbonate). (2) Prepare and evaluate the placement, compressive strength, and thermal properties of the selected formulation with new admixture dosages. (3) Identify opportunities for improving the mix selected by HLW Closure Project personnel and prepare and evaluate two potentially improved zero bleed flowable fill design concepts; one based on the reactor fill grout and the other based on a shrinkage compensating flowable fill mix

  11. Comparative evaluation of microleakage of various retrograde filling materials: An in vitro study.

    Science.gov (United States)

    Galhotra, Virat; Sofat, Anjali; Pandit, Inder K; Gambhir, Ramandeep Singh; Srivastava, Nikhil; Gugnani, Neeraj

    2013-07-01

    The present study is envisaged to evaluate and compare the microleakage of mineral trioxide aggregate (MTA) with commonly used retrograde filling materials, like light-cured composite with dentin-bonding agents, light-cured glass ionomer cement (LC GIC) and resin-modified zinc oxide eugenol. Ninety freshly extracted non-carious single-rooted human anterior teeth were used in the study. They were randomly divided into four experimental groups and two control groups of 15 each. Following the biomechanical preparation, all teeth were obturated and then the apices of the obturated teeth were resected by removing 3 mm of each apex at 90° to the long axis of the tooth with a straight fissure bur in a high-speed air-rotor handpiece with water coolant. A 3-mm-deep root end cavity was prepared and the root end fillings were placed as per the manufacturer's instructions and according to the groups divided. The samples were then immersed in 1% methylene blue at room temperature for 72 h, 96 h and 1 week and the dye penetration was measured. All the four materials used in the study showed some microleakage throughout the experimental period. The sealing ability in terms of microleakage can be summarized as: MTA > Composite resin with dentin bonding agent > LC GIC > Resin modified zinc oxide eugenol.

  12. Broadband giant-refractive-index material based on mesoscopic space-filling curves

    Science.gov (United States)

    Chang, Taeyong; Kim, Jong Uk; Kang, Seung Kyu; Kim, Hyowook; Kim, Do Kyung; Lee, Yong-Hee; Shin, Jonghwa

    2016-08-01

    The refractive index is the fundamental property of all optical materials and dictates Snell's law, propagation speed, wavelength, diffraction, energy density, absorption and emission of light in materials. Experimentally realized broadband refractive indices remain 1,800 resulting from a mesoscopic crystal with a dielectric constant greater than three million. This gigantic enhancement effect originates from the space-filling curve concept from mathematics. The principle is inherently very broad band, the enhancement being nearly constant from zero up to the frequency of interest. This broadband giant-refractive-index medium promises not only enhanced resolution in imaging and raised fundamental absorption limits in solar energy devices, but also compact, power-efficient components for optical communication and increased performance in many other applications.

  13. Three-dimensional evaluation of effectiveness of hand and rotary instrumentation for retreatment of canals filled with different materials.

    Science.gov (United States)

    Hammad, Mohammad; Qualtrough, Alison; Silikas, Nick

    2008-11-01

    The aim of this study was to measure the remaining filling volume of different obturation materials from root-filled extracted teeth by using 2 removal techniques. Eighty single-rooted teeth were collected and decoronated, and the root canal was prepared by using the ProTaper nickel-titanium rotary files. The teeth were randomly allocated into 4 groups, and each group was obturated by using a different material. Group 1 was filled with gutta-percha and TubliSeal sealer, group 2 was filled with EndoRez points and EndoRez sealer, group 3 was filled with RealSeal points and RealSeal sealer, and Group 4 was filled with a gutta-percha point and GuttaFlow sealer. Teeth were scanned with a micro-computed tomography scan, and then root fillings were removed by using ProTaper retreatment files or hand K-files. Teeth were scanned again, and volume measurements were carried out with micro-computed tomography software. Statistical analysis showed significant differences between the 2 removal techniques for gutta-percha and for both techniques between gutta-percha and the other groups. The present study showed that all tested filling materials were not completely removed during retreatment by using hand or rotary files. Gutta-percha was more efficiently removed by using hand K-files.

  14. Synthesis of partial stabilized cement-gypsum as new dental retrograde filling material

    Energy Technology Data Exchange (ETDEWEB)

    Sadhasivam, S. [Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan (China); Division of Medical Engineering Research, National Health Research Institute, Zhunan, Miaoli County, Taiwan (China); Chen, Jung-Chih [Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan (China); Medical Device Innovation Center, National Cheng Kung University, Tainan,Taiwan (China); Savitha, S. [Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan (China); Hsu, Ming-Xiang; Hsu, Chung-King [Institute of Materials Science and Engineering, National Taipei University of Technology, Taipei, Taiwan (China); Lin, Chun-Pin [School of Dentistry and Graduate Institute of Clinical Dentistry, College of Medicine, National Taiwan University and National Taiwan University Hospital, Taipei, Taiwan (China); Lin, Feng-Huei, E-mail: double@ntu.edu.tw [Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan (China); Division of Medical Engineering Research, National Health Research Institute, Zhunan, Miaoli County, Taiwan (China)

    2012-10-01

    The study describes the sol-gel synthesis of a new dental retrograde filling material partial stabilized cement (PSC)-gypsum by adding different weight percentage of gypsum (25% PSC + 75% gypsum, 50% PSC + 50% gypsum and 75% PSC + 25% gypsum) to the PSC. The crystalline phase and hydration products of PSC-gypsum were characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis. The handling properties such as setting time, viscosity, tensile strength, porosity and pH, were also studied. The XRD and microstructure analysis demonstrated the formation of hydroxyapatite and removal of calcium dihydrate during its immersion in simulated body fluid (SBF) on day 10 for 75% PSC + 25% gypsum. The developed PSC-gypsum not only improved the setting time but also greatly reduced the viscosity, which is very essential for endodontic surgery. The cytotoxic and cell proliferation studies indicated that the synthesized material is highly biocompatible. The increased alkaline pH of the PSC-gypsum also had a remarkable antibacterial activity. - Highlights: Black-Right-Pointing-Pointer A new dental retrograde filling material PSC-gypsum was developed. Black-Right-Pointing-Pointer PSC-gypsum cement has shown excellent initial and final setting time as 15-35 min. Black-Right-Pointing-Pointer It not only improved the setting time but also retain the viscosity, 2 Pa{center_dot}s. Black-Right-Pointing-Pointer High alkaline pH of the cement had a remarkable antibacterial activity. Black-Right-Pointing-Pointer Cytotoxicity studies revealed that the synthesized material is highly biocompatible.

  15. Radiopacity evaluation of new root canal filling materials by digitalization of images.

    Science.gov (United States)

    Tanomaru-Filho, Mário; Jorge, Erica Gouveia; Guerreiro Tanomaru, Juliane Maria; Gonçalves, Marcelo

    2007-03-01

    The aim of this study was to evaluate the radiopacity of five root canal filling materials (AH Plus, Intrafill, Roeko Seal, Epiphany, and EndoRez). Following the International Organization of Standardization 6876/2001, five circular specimens (10 x 1 mm) were made from each material. After the material set, radiographs were made using occlusal film and a graduated aluminum step-wedge varying in thickness from 2 to 16 mm. The dental X-ray unit (GE1000) was set at 50 Kvp, 10 mA, 18 pulses/second, and distance of 33.5 cm. The radiographs were digitized, and the radiopacity was compared with the aluminum step-wedge, using WIXWIN-2000 software (Gendex). Data (mm Al) were analyzed using ANOVA and Tukey tests. AH Plus and Epiphany were the most radiopaque materials (9.8 and 8.8 mm Al, respectively), followed by EndoRez (7.2 mm Al). Roeko Seal and Intrafill presented the lowest radiopacity values (5.7 and 6.1 mm Al, respectively). Although the materials evaluated demonstrated different radiopacities, all had values above the minimum recommended by the International Organization of Standardization.

  16. Nd:YAG laser in endodontics: filling-material edge bordering on a root channel laser cavity

    Science.gov (United States)

    Belikov, Andrei V.; Sinelnik, Yuri A.; Moroz, Boris T.; Pavlovskaya, Irina V.

    1997-12-01

    For the very first time it is represented a study of filling material edge bordering upon root channel cavity modified with a laser. As a filling material it is used a glass ionomer cement. It is demonstrated that Nd:YAG laser radiation effects on increase of grade of edge bordering on the average of 20 - 30% at temperature rise of no more than 2 - 3 degrees in periodontium area in a period of operation.

  17. Study on filling materials suitable for seawater piping trench closure work at Fukushima Daiichi Nuclear Power Plant

    International Nuclear Information System (INIS)

    Yanai, Shuji; Hibi, Yasuki; Nishikori, Kazumasa; Sato, Keita

    2016-01-01

    Highly contaminated water leaking from the reactor buildings and turbine buildings damaged by the 2011 Great East Japan Earthquake has accumulated in the seawater piping trenches of Fukushima Daiichi Nuclear Power Station Units 2, 3, and 4. In November 2014, work commenced to replace and remove this contaminated water by filling the trenches with filling materials, and this work was completed in December 2015. This paper summarizes the contents of this study on various filling materials, including special fillers with long-distance underwater flowability applied to the horizontal tunnel parts of the trenches. (author)

  18. Midfacial analysis and planning for midface augmentation with injectable filling materials: an anatomical approach.

    Science.gov (United States)

    Taheri, A; Mansoori, P

    2012-06-01

      Midfacial augmentation improves the appearance of patients with flat or ptotic cheek.   To develop a simple method of preoperative delineating the location of the ideal malar prominence and determining the best area to augment with injectable filling materials.   We used detailed analysis of the facial features of some Caucasian men and women as the basis for this study.   We described a technique to locate the ideal malar prominence and proposed a classification of midfacial contour defects.   This method greatly simplifies the surgeon's task of determining the area to be augmented. © 2011 The Authors. Journal of the European Academy of Dermatology and Venereology © 2011 European Academy of Dermatology and Venereology.

  19. Evaluation of a new nano-filled restorative material for bonding orthodontic brackets.

    Science.gov (United States)

    Bishara, Samir E; Ajlouni, Raed; Soliman, Manal M; Oonsombat, Charuphan; Laffoon, John F; Warren, John

    2007-01-01

    To compare the shear bond strength of a nano-hybrid restorative material, Grandio (Voco, Cuxhaven, Germany), to that of a traditional adhesive material (Transbond XT; 3M Unitek, Monrovia, CA, USA) when bonding orthodontic brackets. Forty teeth were randomly divided into 2 groups: 20 teeth were bonded with the Transbond adhesive system and the other 20 teeth with the Grandio restorative system, following manufacturer's instructions. Student t test was used to compare the shear bond strength of the 2 systems. Significance was predetermined at P 5 .05. The t test comparisons (t = 0.55) of the shear bond strength between the 2 adhesives indicated the absence of a significant (P = .585) difference. The mean shear bond strength for Grandio was 4.1 +/- 2.6 MPa and that for Transbond XT was 4.6 +/- 3.2 MPa. During debonding, 3 of 20 brackets (15%) bonded with Grandio failed without registering any force on the Zwick recording. None of the brackets bonded with Transbond XT had a similar failure mode. The newly introduced nano-filled composite materials can potentially be used to bond orthodontic brackets to teeth if its consistency can be more flowable to readily adhere to the bracket base.

  20. Potential of fish scales as a filling material in surface coating of cellulosic paper.

    Science.gov (United States)

    Ural, Elif; Kandirmaz, Emine A

    2018-01-01

    Paper is one of the important inputs for the printing industry, and the most important leading parameter in the printing process is its brightness. Brightness can be brought to paper using coatings and sizing. Desired surface properties and, most importantly, surface roughness can be achieved by changing the contents of the coating and sizing of the materials it contains. The use of biomaterials is becoming more important in the paper industry, as they represent substances with a lower carbon footprint. Fish scales are already used as a filling material, cosmetic material and fish food, as well as for determining the age of fish. Fish scales were brought to different sizes by a milling process. Paper formulations including different amounts of fish scales were prepared with fish scales, and coatings on raw paper were subjected to test printings in IGT-C1, with formulations and physical characteristics of coatings such as brightness, lightfastness, strength, adhesion etc. being determined. Regarding the value of yellowness, mixtures of 2.5%-10% can be used. The maximum value of brightness was obtained from a mixture of 10%. Aging visibly changed the colors. The coatings obtained were brighter than the initial coating compositions. The top quality formulation was the coating with 5% medium-sized fish scale particles.

  1. Evaluation of physicochemical properties of root-end filling materials using conventional and Micro-CT tests

    Directory of Open Access Journals (Sweden)

    Fernanda Ferrari Esteves TORRES

    Full Text Available Abstract Objective To evaluate solubility, dimensional stability, filling ability and volumetric change of root-end filling materials using conventional tests and new Micro-CT-based methods. Material and Methods Solubility (loss of mass after 7 and 30 days, and dimensional stability (in mm were evaluated in accordance with Carvalho-Junior, et al. 7 (2007. The filling ability and volumetric change (in mm3 were evaluated by Micro-CT (Bruker-MicroCT, Kontich, Belgium using resin models with cavities 3 mm deep and 1 mm in diameter. The cavities were filled with materials to evaluate filling ability, and then scanned by Micro-CT. After 7 and 30 days immersed in distilled water, the filled cavities were scanned again to evaluate the volumetric change. MTA Angelus (MTA, Biodentine (BIO and zinc oxide-eugenol cement (ZOE were evaluated. Data were submitted to analysis of variance (ANOVA and Tukey's test with 5% significance level. Results The results suggested correlated or complementary data between the proposed tests. At 7 days, BIO showed higher solubility and at 30 days, showed higher volumetric change in comparison with MTA (p0.05 at 7 days. At 30 days, they presented similar solubility. BIO and MTA showed higher dimensional stability than ZOE (p<0.05. ZOE and BIO showed higher filling ability (p<0.05. Conclusions ZOE presented a higher dimensional change, and BIO had greater solubility after 7 days. BIO presented filling ability and dimensional stability, but greater volumetric change than MTA after 30 days. Micro-CT can provide important data on the physicochemical properties of materials complementing conventional tests.

  2. Rock fill in a KBS-3 repository. Rock material for filling of shafts and ramps in a KBS-3V repository in the closure phase

    International Nuclear Information System (INIS)

    Pusch, Roland

    2008-09-01

    The content of large blocks in blasted rock makes it impossible to fill and compact the material effectively unless those larger than about 500 mm are removed. Tunnel Boring Machine (TBM) muck gives flat chips, that are usually not longer than a couple of decimeters, and serves better as backfill. The granulometrical composition of both types can be more suitable for effective compaction by crushing, which is hence a preferable process. Use of unsorted, unprocessed blasted rock can only be accepted if the density and physical properties, like self-compaction, are not important. Crushing of blasted rock and TBM muck for backfilling can be made in one or two steps depending on the required gradation. Placement of rock fill is best made by use of tractors with blades that push the material forwards over already placed and compacted material. The dry density of well graded rock fill effectively compacted by very heavy vibratory rollers can be as high as 2,400 kg/m3. For road compaction by ordinary vibratory rollers common dry density values are in the interval 2,050 to 2,200 kg m 3 . Blasted rock dumped and moved on site by tractors can get an average dry density of 1,600-1,800 kg/m3 without compaction. Crushed, blasted rock and TBM muck placed by tractors in horizontal layers and compacted by 5-10 t vibrating rollers in the lower part of the rooms, and moved by tractors to form inclined layers compacted by vibrating plates in the upper part, would get a dry density of 1,900-2,000 kg/m 3 . Flushing water over the rock fill in conjunction with the compaction work gives more effective densification than dry compaction. Based on recorded settlement of Norwegian rock fill dams constructed with water flushing it is estimated that the self-compaction of a 5 m high backfill of crushed rock or TBM muck causes a settlement of the top of the backfill of about 8 mm while a 200 m high shaft fill would undergo compression by more than half a meter. Repeated, strong earthquakes may

  3. Rock fill in a KBS-3 repository. Rock material for filling of shafts and ramps in a KBS-3V repository in the closure phase

    Energy Technology Data Exchange (ETDEWEB)

    Pusch, Roland (Geodevelopment International AB/SWECO AB, Lund (Sweden))

    2008-09-15

    The content of large blocks in blasted rock makes it impossible to fill and compact the material effectively unless those larger than about 500 mm are removed. Tunnel Boring Machine (TBM) muck gives flat chips, that are usually not longer than a couple of decimeters, and serves better as backfill. The granulometrical composition of both types can be more suitable for effective compaction by crushing, which is hence a preferable process. Use of unsorted, unprocessed blasted rock can only be accepted if the density and physical properties, like self-compaction, are not important. Crushing of blasted rock and TBM muck for backfilling can be made in one or two steps depending on the required gradation. Placement of rock fill is best made by use of tractors with blades that push the material forwards over already placed and compacted material. The dry density of well graded rock fill effectively compacted by very heavy vibratory rollers can be as high as 2,400 kg/m3. For road compaction by ordinary vibratory rollers common dry density values are in the interval 2,050 to 2,200 kg m3. Blasted rock dumped and moved on site by tractors can get an average dry density of 1,600-1,800 kg/m3 without compaction. Crushed, blasted rock and TBM muck placed by tractors in horizontal layers and compacted by 5-10 t vibrating rollers in the lower part of the rooms, and moved by tractors to form inclined layers compacted by vibrating plates in the upper part, would get a dry density of 1,900-2,000 kg/m3. Flushing water over the rock fill in conjunction with the compaction work gives more effective densification than dry compaction. Based on recorded settlement of Norwegian rock fill dams constructed with water flushing it is estimated that the self-compaction of a 5 m high backfill of crushed rock or TBM muck causes a settlement of the top of the backfill of about 8 mm while a 200 m high shaft fill would undergo compression by more than half a meter. Repeated, strong earthquakes may

  4. 33 CFR 336.1 - Discharges of dredged or fill material into waters of the U.S.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Discharges of dredged or fill material into waters of the U.S. 336.1 Section 336.1 Navigation and Navigable Waters CORPS OF ENGINEERS... ENGINEERS DREDGING PROJECTS INVOLVING THE DISCHARGE OF DREDGED MATERIAL INTO WATERS OF THE U.S. AND OCEAN...

  5. 3D Surface Profile and Color Stability of Tooth Colored Filling Materials after Bleaching

    Directory of Open Access Journals (Sweden)

    Bryant Anthony Irawan

    2015-01-01

    Full Text Available This study aims to evaluate the effects of vital tooth bleaching with carbamide peroxide home bleaching and in-office bleaching on the color stability and 3D surface profile of dental restorative filling materials. Thirty discs (n=30 measure 6 mm in diameter and 2 mm thick for each of three restorative materials. These are nanofilled composite Filtek Z350 XT, the submicron composite Estelite Σ Quick, and nanofilled glass ionomer Ketac N100 nanoionomer and were fabricated in shade A2. Each group was further divided into three subgroups (n=10: subgroup A (Opalescence PF, subgroup B (Opalescence Boost in-office bleaching, and subgroup C (distilled water serving as control. Samples were bleached according to the manufacturer’s instructions for a period of two weeks. The Commission Internationale de L’Eclairage (CIE L*, a*, b* system was chosen for image processing, while 3D surface profile was tested with atomic force microscopy (AFM. Statistical analyses were performed with the Mann-Whitney tests and Krusal-Wallis with a P value of ≤0.05. The three restorative materials showed significant color changes (ΔE; P≤0.05. In diminishing order, the mean color changes recorded were Estelite Σ (3.82 ± 1.6 > Ketac Nano (2.97 ± 1.2 > Filtek Z350 XT (2.25 ± 1.0. However, none of the tested materials showed statistically significant changes in surface roughness; P>0.05.

  6. The apical leakage of mineral trioxide aggregate as the retrograde filling material with various mixing agents

    Directory of Open Access Journals (Sweden)

    Ema Mulyawati

    2010-06-01

    Full Text Available Background: Mineral trioxide aggregate (MTA is relatively considered as a new material in endodontic. It even has been used as retrograde filling material due to its biocompatibility, antibacterial effect, sealing ability and anti-moist effect. Some materials have been used as mixing agent to achieve an appropiate setting of MTA. Purpose: The aim of this study is to investigate the effect of the mixing agents of MTA towards the apical leakage when they are used together as retrograde filling materials. Method: The samples of this research consist of 30 human extracted upper central incisors. First, the crown of each tooth is sectioned. The root canals are prepared by using the conventional technique and then are obturated with gutta percha. After cutting the root apex, 2 mm from apical, class 1 cavities are prepared by using fissure bur with the depth of 3 mm. The samples then are divided into 3 groups with 10 teeth for each. Group I uses aquabidest as mixing agent of MTA (MTA-aquabidest, group II uses saline (MTA-saline, while group III uses 0.12% chlorhexidine (MTA-chlorhexidine. The apex of each group then is filled with the mixing MTA determined already. Afterwards, clearing method is used to evaluate the apical leakage. The apical leakage actually is determined by measuring the depth of methylene blue penetration with stereomicroscope. The statictical analyses of the linear dye penetration then are performed with analysis of varians ANOVA. Result: The dye penetration for both MTA-aquadest and MTA-saline groups indicates the lowest penetration, and there is even a significant difference compared with MTA-0.12% chlorhexidine group (p<0.005. Conclusion: It can be concluded that aquabidest and saline as mixing agents of MTA produce less apical leakage compared with 0.12% chlorhexidine.Latar belakang: Mineral trioxide aggregate (MTA merupakan bahan yang relatif baru dalam bidang endodontik. Bahan tersebut diindikasikan sebagai bahan pengisi

  7. Comparison of the sealing ability of mineral trioxide aggregate and Portland cement used as root-end filling materials.

    Science.gov (United States)

    Shahi, Shahriar; Yavari, Hamid R; Rahimi, Saeed; Eskandarinezhad, Mahsa; Shakouei, Sahar; Unchi, Mahsa

    2011-12-01

    Inadequate apical seal is the major cause of surgical endodontic failure. The root-end filling material used should prevent egress of potential contaminants into periapical tissue. The purpose of this study was to compare the sealing ability of four root-end filling materials: white mineral trioxide aggregate (MTA), gray MTA, white Portland cement (PC) and gray PC by dye leakage test. Ninety-six human single-rooted teeth were instrumented, and obturated with gutta-percha. After resecting the apex, an apical cavity was prepared. The teeth were randomly divided into four experimental groups (A: white MTA, B: gray MTA, C: white PC and D: gray PC; n = 20) and two control groups (positive and negative control groups; n = 8). Root-end cavities in the experimental groups were filled with the experimental materials. The teeth were exposed to Indian ink for 72 hours. The extent of dye penetration was measured with a stereomicroscope at 16× magnification. The negative controls showed no dye penetration and dye penetration was seen in the entire root-end cavity of positive controls. However, there was no statistically significant difference among the four experimental groups (P > 0.05). All retrograde filling materials tested in this study showed the same microleakage in vitro. Given the low cost and apparently similar sealing ability of PC, PC could be considered as a substitute for MTA as a root-end filling material.

  8. Friction Properties of Laminated Composite Materials of Alpha-Tricalcium Phosphate–Filled Poly (Vinyl Alcohol) Hydrogels

    OpenAIRE

    Yamamoto, Kanae; Iwai, Tomoaki; Shoukaku, Yutaka

    2015-01-01

    The aim of this study was to examine the mechanical characteristics of a polyvinyl alcohol hydrogel (PVA-H) as a candidate material for artificial joint cartilage. In the study, PVA-H was filled with α-tricalcium phosphate (α-TCP) in order to improve its mechanical properties. In addition, laminated composite materials with 3 layers were prepared by laminating α-TCP–filled PVA-H and unfilled PVA-H. The samples were prepared with different numbers of repeated freeze–thaw cycles and several con...

  9. Designing dual phase sensing materials from polyaniline filled styrene–isoprene–styrene composites

    International Nuclear Information System (INIS)

    Sadasivuni, Kishor Kumar; Ponnamma, Deepalekshmi; Kasak, Peter; Krupa, Igor; Ali S A Al-Maadeed, Mariam

    2014-01-01

    The demand for developing oil detectors is ever increasing since the cleanup and recovery from oil spill usually take long time. Here we propose oil sensors made of polyaniline (PANI) filled poly(styrene–isoprene–styrene) (SIS) block copolymer composite films with good uniformity and dispersion. The changes in resistivity of the samples in presence of both oil and water media reveal the good sensing ability of SIS–PANI films towards oil in water (dual phase). The morphology and chemical composition of the developed products are characterized by scanning electron microscopy and Fourier transformation infrared spectroscopy. Swelling studies are performed to correlate the sensing response to the structural variations and based on it a mechanism is derived for the dual phase sensing. Contact angle measurements confirm the behavior further. The thermal properties and crystallinity of the composites are also addressed by the thermogravimetric and differential scanning calorimetric studies. The developed oil sensor material is able to withstand extreme temperature condition as well. - Highlights: • We model a dual phase sensor capable of detecting oil in water. • A mechanism is proposed to correlate sensing with diffusion. • In situ polymerization helps in the uniform distribution of filler. • Polymer composite sensor could be used as stickers on oil pipelines

  10. Cytotoxic effects of cyanoacrylates used as retrograde filling materials: an in vitro analysis

    Directory of Open Access Journals (Sweden)

    Azevedo Cledson Lima de

    2003-01-01

    Full Text Available Cyanoacrylate has been used in medicine and dentistry for many years. It has been used as a postextraction dressing and retrograde filling material in endodontic surgery. The aim of this study was to evaluate the cytotoxic effects of Histoacryl and other two homologue ethyl cyanoacrylates, Super Bonder and Ultrabond, on cultured fibroblasts, using the Trypan blue dye exclusion assay. The cyanoacrylates were applied to round glass coverslips, which were placed in contact with NIH 3T3 cells. After 0, 6, 12 and 24 h (short-term assay; viability and 1, 3, 5 and 7 days (long-term assay; survival, the cells were examined under phase light microscopy and counted. The data were compared by the Kruskal-Wallis test. In the short-term experiments, only the cultures of the Ultrabond group (GIV presented significant smaller percentages of cell viability than the cultures of the other groups (GI: control; GII: Super Bonder; GIII: Histoacryl. Although the cultures of the Super Bonder group (GII presented smaller percentages of cell viability than cultures of the other groups (GI, GIII, GIV at the long-term assay, this group was the only experimental group presenting a continuous and progressive cell growth. Our results have shown an in vitro biocompatibility of Histoacryl and ethyl cyanoacrylate homologues. These cyanoacrylates could therefore be of importance for endodontic purposes.

  11. Designing dual phase sensing materials from polyaniline filled styrene–isoprene–styrene composites

    Energy Technology Data Exchange (ETDEWEB)

    Sadasivuni, Kishor Kumar, E-mail: kishor_kumars@yahoo.com [Centre for Advanced Materials, Qatar University, Doha (Qatar); Ponnamma, Deepalekshmi [School of Chemical Sciences, Mahatma Gandhi University, Kottayam 686560, Kerala (India); Kasak, Peter; Krupa, Igor; Ali S A Al-Maadeed, Mariam [Centre for Advanced Materials, Qatar University, Doha (Qatar)

    2014-10-15

    The demand for developing oil detectors is ever increasing since the cleanup and recovery from oil spill usually take long time. Here we propose oil sensors made of polyaniline (PANI) filled poly(styrene–isoprene–styrene) (SIS) block copolymer composite films with good uniformity and dispersion. The changes in resistivity of the samples in presence of both oil and water media reveal the good sensing ability of SIS–PANI films towards oil in water (dual phase). The morphology and chemical composition of the developed products are characterized by scanning electron microscopy and Fourier transformation infrared spectroscopy. Swelling studies are performed to correlate the sensing response to the structural variations and based on it a mechanism is derived for the dual phase sensing. Contact angle measurements confirm the behavior further. The thermal properties and crystallinity of the composites are also addressed by the thermogravimetric and differential scanning calorimetric studies. The developed oil sensor material is able to withstand extreme temperature condition as well. - Highlights: • We model a dual phase sensor capable of detecting oil in water. • A mechanism is proposed to correlate sensing with diffusion. • In situ polymerization helps in the uniform distribution of filler. • Polymer composite sensor could be used as stickers on oil pipelines.

  12. The effects of irradiance and exposure time on the surface roughness of bulk-fill composite resin restorative materials

    Science.gov (United States)

    Alkhudhairy, Fahad I.

    2018-01-01

    Objectives: To evaluate the surface roughness of 4 different bulk-fill resin-based composites cured using different irradiance levels. Methods: This in vitro study was performed in February 2017 to August 2017 at the College of Dentistry, King Saud University. Twenty-four specimens were prepared from each of the bulk-fill materials [Tetric N-Ceram (TNC), SonicFill (SF), Smart Dentin Replacement (SDR), and Filtek Bulk-Fill (FB)] using a brass metal mold, resulting in a total of 96 specimens, cured using a Bluephase N light curing unit. Half of the total number of specimens (N=48) were cured using high-power irradiance (1200 mW/cm2) for 20 seconds, while the remaining half (N=48) were cured using low power irradiance (650 mW/cm2) for 40 seconds. After 24 hours, baseline surface roughness of each specimen was analyzed using a profilometer, then polished using Sof-lex abrasive disks, and the surface roughness of all groups was assessed. Results: Post-polished SonicFill cured at high irradiance had the highest mean surface roughness (0.23±0.03), whereas pre-polished Smart Dentin Replacement (0.11±0.01) and SonicFill (0.11±0.02) cured at low irradiance had the lowest mean surface roughness. Conclusion: High curing irradiance (1,200 mW/cm2) had no positive influence on the surface roughness of Filtek Bulk Fill and Tetric N-Ceram bulk-fill RBCs compared with lower curing irradiance (650 mW/cm2). However, the difference of curing irradiance significantly affected the surface roughness in SDR and sonic fill RBCs. PMID:29436570

  13. Depleted uranium oxides as spent-nuclear-fuel waste-package fill materials

    International Nuclear Information System (INIS)

    Forsberg, C.W.

    1997-01-01

    Depleted uranium dioxide fill inside the waste package creates the potential for significant improvements in package performance based on uranium geochemistry, reduces the potential for criticality in a repository, and consumes DU inventory. As a new concept, significant uncertainties exist: fill properties, impacts on package design, post- closure performance

  14. Influence of dental filling material type on the concentration of interleukin 9 in the samples of gingival crevicular fluid

    Directory of Open Access Journals (Sweden)

    Stefanović Vladimir

    2016-01-01

    Full Text Available Background/Aim. Several cytokines and lymphokines (IL1β, ENA78, IL6, TNFα, IL8 and S100A8 are expressed during dental pulp inflammation. Analysis of gingival crevicu-lar fluid (GCF offers a non-invasive means of studying gen-eral host response in oral cavity. Although GCF levels of various mediators could reflect the state of inflammation both in dental pulp and gingiva adjacent to a tooth, GCF samples of those without significant gingivitis could be inter-preted as reflection of pulpal process. The aim of this study was to investigate IL9 GCF values in patients with dental car-ies and to assess possible influence of various dental fillings materials on local IL9 production. Methods. The study group included 90 patients, aged 18–70, with inclusion and exclusion criteria in the prospective clinical study. Of the 6 types of material used for the restoration of prepared cavities, 3 were intended for temporary and 3 for definitive restora-tion. According to dental fillings weight, all the participants were divided into 3 groups: those with fillings lighter than 0.50 g, those with 0.50–1.00 g, and those with fillings heavier than 1.00 g. Samples were taken from gingival sulcus using the filter paper technique. Clinical parameters were deter-mined by bleeding index, plaque index (Silness-Lou, 0–3, gingival index (0–3, and gingival sulcus depth. Cytokine con-centrations were assessed using commercially available cy-tomix. Results. According to the weight of dental fillings, there was a clear decreament trend of IL9 values meaning that dental defects greater than 1.00 g of dental filling were associated with lower GCF IL9 concentration. The IL9 val-ues correlated with the degree of gingival index and depth of gingival sulcus, being higher with more advanced gingivitis and more pronounced anatomical changes in the tooth edge. Different filling materials exerted various local IL9 responses. Zink polycarbonate cement and amalgam fillings induced

  15. About Dental Amalgam Fillings

    Science.gov (United States)

    ... and Medical Procedures Dental Devices Dental Amalgam About Dental Amalgam Fillings Share Tweet Linkedin Pin it More ... should I have my fillings removed? What is dental amalgam? Dental amalgam is a dental filling material ...

  16. Quantitative assessment of image artifacts from root filling materials on CBCT scans made using several exposure parameters

    Energy Technology Data Exchange (ETDEWEB)

    Rabelo, Katharina Alves; Cavalcanti, Yuri Wanderley; De Oliveira Pinto, Martina Gerlane; De Melo, Daniela Pita [Dept. of Oral Diagnosis, State University of Paraiba, Campina Grande (Brazil); Melo, Saulo Leonardo Sousa [Dept. of Oral Pathology, Radiology and Medicine, University of Iowa, Iowa City (United States); Campos, Paulo Sergio Flores; De Andrade Freitas Oliveira, Luciana Soares [Federal University of Bahia, Salvador (Brazil)

    2017-09-15

    To quantify artifacts from different root filling materials in cone-beam computed tomography (CBCT) images acquired using different exposure parameters. Fifteen single-rooted teeth were scanned using 8 different exposure protocols with 3 different filling materials and once without filling material as a control group. Artifact quantification was performed by a trained observer who made measurements in the central axial slice of all acquired images in a fixed region of interest using ImageJ. Hyperdense artifacts, hypodense artifacts, and the remaining tooth area were identified, and the percentages of hyperdense and hypodense artifacts, remaining tooth area, and tooth area affected by the artifacts were calculated. Artifacts were analyzed qualitatively by 2 observers using the following scores: absence (0), moderate presence (1), and high presence (2) for hypodense halos, hypodense lines, and hyperdense lines. Two-way ANOVA and the post-hoc Tukey test were used for quantitative and qualitative artifact analysis. The Dunnet test was also used for qualitative analysis. The significance level was set at P<.05. There were no significant interactions among the exposure parameters in the quantitative or qualitative analysis. Significant differences were observed among the studied filling materials in all quantitative analyses. In the qualitative analyses, all materials differed from the control group in terms of hypodense and hyperdense lines (P<.05). Fiberglass posts did not differ statistically from the control group in terms of hypodense halos (P>.05). Different exposure parameters did not affect the objective or subjective observations of artifacts in CBCT images; however, the filling materials used in endodontic restorations did affect both types of assessments.

  17. Experimental investigation of different fill materials in arch bridges with particular focus on Pearl-Chain Bridges

    DEFF Research Database (Denmark)

    Lund, Mia Schou Møller; Hansen, Kurt Kielsgaard; Hertz, Kristian Dahl

    2016-01-01

    Pearl-Chain Bridge technology is a recently developed prefabricated arch solution for road and railway bridges allowing faster, more environmentally friendly, and cheaper bridge construction. This study compared the strength and durability properties of three different types of fill material...

  18. Quantitative assessment of image artifacts from root filling materials on CBCT scans made using several exposure parameters

    International Nuclear Information System (INIS)

    Rabelo, Katharina Alves; Cavalcanti, Yuri Wanderley; De Oliveira Pinto, Martina Gerlane; De Melo, Daniela Pita; Melo, Saulo Leonardo Sousa; Campos, Paulo Sergio Flores; De Andrade Freitas Oliveira, Luciana Soares

    2017-01-01

    To quantify artifacts from different root filling materials in cone-beam computed tomography (CBCT) images acquired using different exposure parameters. Fifteen single-rooted teeth were scanned using 8 different exposure protocols with 3 different filling materials and once without filling material as a control group. Artifact quantification was performed by a trained observer who made measurements in the central axial slice of all acquired images in a fixed region of interest using ImageJ. Hyperdense artifacts, hypodense artifacts, and the remaining tooth area were identified, and the percentages of hyperdense and hypodense artifacts, remaining tooth area, and tooth area affected by the artifacts were calculated. Artifacts were analyzed qualitatively by 2 observers using the following scores: absence (0), moderate presence (1), and high presence (2) for hypodense halos, hypodense lines, and hyperdense lines. Two-way ANOVA and the post-hoc Tukey test were used for quantitative and qualitative artifact analysis. The Dunnet test was also used for qualitative analysis. The significance level was set at P .05). Different exposure parameters did not affect the objective or subjective observations of artifacts in CBCT images; however, the filling materials used in endodontic restorations did affect both types of assessments

  19. Feasibility of soil-EFB mixtures as a filled barrier material for waste disposal site

    International Nuclear Information System (INIS)

    Kamarudin Samuding; Ismail Abustan; Mohd Tadza Abdul Rahman; Mohamed Hasnain Isa

    2010-01-01

    This paper present the results of laboratory experiment that is involved the characterization and removal efficiency test of soil-EFB (Empty Fruit Bunch) of oil palm mixture. In this study, soil samples were mixed with EFB at 10 % (EFB10), 30 % (EFB30), and 50 % (EFB50). The characterization included the physical and chemical properties of the soil-EFB mixture such as compaction behaviour, cation exchange capacity, permeability and its surface physical morphology. Batch Equilibrium Test was performed in order to determine the adsorption capability of the soil-EFB mixture with the heavy metals solution. Five solutions with different concentrations (2.5 mg/l, 5.0 mg/l, 7.5 mg/l, 10.0 mg/l and 12.5 mg/l) were used in this experiment. Base on the compaction test, the value of optimum water content was influence by the EFB introduced into the soil. This is due to the presence of hydroxyl group, which was probably attributed to absorb water. The permeability of the soil-EFB mixtures ranges from 2.4 x 10 -7 to 6.5 x 10 -7 cm/s meanwhile the Cation Exchange Capacity (CEC) result ranges from 11.6 to 31.9 meq/ 100 g. The study has revealed that different percentages of soil-EFB mixture possess different capabilities to remove heavy metals. From the removal efficiency test, it is shown that the removal percentages of heavy metals for soil-EFB mixtures were relatively high as compared to soil alone. Based on the characterization and removal data, the soil-EFB mixture has a good potential to be used as filled barrier material. (author)

  20. Filling material for a buried cavity in a collapse area using light-weighted foam and active feldspar

    Science.gov (United States)

    Cho, Jin Woo; Lee, Ju-hyoung; Kim, Sung-Wook; Choi, Eun-Kyeong

    2017-04-01

    Concrete which is generally used as filling material for a buried cavity has very high strength but significantly high self-load is considered its disadvantage. If it is used as filling material, the second collapse due to additional load, causing irreversible damage. If light-weighted foam and active feldspar are used to solve this problem, the second collapse can be prevented by reducing of self-load of filling material. In this study, the specimen was produced by mixing light-weighted foam, active feldspar and cement, and changes in the density, unconfined compressive strength and hydraulic conductivity were analyzed. Using the light-weighted foam could enable the adjustment of density of specimen between 0.5 g/cm3 and 1.7 g/cm3, and if the mixing ratio of the light-weighted foam increases, the specimen has more pores and smaller range of cross-sectional area. It is confirmed that it has direct correlation with the density, and if the specimen has more pores, the density of the specimen is lowered. The density of the specimen influences the unconfined compressive strength and the hydraulic conductivity, and it was also confirmed that the unconfined compressive strength could be adjusted between 0.6 MPa and 8 MPa and the hydraulic conductivity could be adjusted between 10-9cm/sec and 10-3cm/sec. These results indicated that we can adjust unconfined compressive strength and hydraulic conductivity of filling materials by changing the mixing amount of lightweight-weighted foam according to the requirements of the field condition. Keywords: filling material, buried cavity, light-weighted foam, feldspar Acknowledgement This research was supported by a Grant from a Strategic Research Project (Horizontal Drilling and Stabilization Technologies for Urban Search and Rescue (US&R) Operation) funded by the Korea Institute of Civil Engineering and Building Technology.

  1. Elaboration of protocol for characterization of clay as a filling material and coverage for surface repository

    International Nuclear Information System (INIS)

    Santos, Daisy Mary Marchezini dos

    2017-01-01

    The nuclear energy in its various applications generates wastes that must be properly treated. The Radioactive Waste Management covers operations since generation of the waste until to its storage in repository ensuring the protection of man and of environment of the possible negative impacts. The radioactive waste are segregated, treated, conditioned in suitable packaging and posteriorly are stored or disposal in repository. The “RBMN Project” is a priority project of CNEN to implementation the repository for the deposition of low and intermediate level radioactive waste generated by nuclear energy activities in Brazil, proposing a definitive solution for its storage. Engineered and natural barriers as the filling layer and coverage layer will compose the disposal system of a near surface repository, concept proposed by the “RBMN Project”. The use these barriers views to avoid or restrict the release of radionuclides present in waste for the humans beings and environment. The waterproofing barriers are composed of clays. Certainly, for the national repository, will be used those clays existing in the place where it will be implanted it. So some fundamentals tests will have to be carried for to verify the suitability of these clays as barriers. These tests were determined and realized with a reference clay, a brazilian bentonite constituted of 67.2% montmorillonite. The results were compared with national and international literature of materials with similar mineralogical features. The values found with 95% reliance were 9.73±0,35 μm for granulometric size. For the moisture content were 13,3±0,6% and for capacity of cationic exchange were , 816±9 mmol.kg"-"1. For the hydraulic conductivity, without the use of internal pressure, it was obtained maximum value of 59.0% saturated. In addition, during the observed period, there was no percolation in the test specimen submitted to internal pressure of 200 kPa. This result leads to the conclusion that the

  2. Proportioning equipment for vibration filling and compacting of grain materials in pipe containers, especially of fuel elements

    International Nuclear Information System (INIS)

    Pinkas, V.; Filip, Z.; Beranek, J.

    1981-01-01

    The equipment consists of a base plate to which are attached the fastening collar fo the pipe container and the guide column with the height-adjustable support. The filling pipe is fixed to the support. The proportioning equipment prevents particles of grain material from segregation, thus allowing to achieve homogeneity of the material in the whole volume to be compacted. It also allows determining the height of the column of material in the pipe container without destructive effects on the stacked material. The equipment is designed for the manufacture of shortened fuel elements. (J.B.)

  3. Condições mais frequentes em um ambulatório de perícia neurológica The most common disorders in neurological clinic for medico-legal assessment of labour capacity at the Brazilian Social Security System (INSS in Florianópolis - SC, Brazil

    Directory of Open Access Journals (Sweden)

    Paulo Cesar Trevisol-Bittencourt

    2001-06-01

    Full Text Available OBJETIVO: Apresentar as condições nosológicas vistas em perícia neurológica em um ambulatório de referência estadual do Instituto Nacional de Seguridade Social (INSS, Florianópolis, Santa Catarina, Brasil, durante o período de outubro de 97 a maio de 98. MÉTODO: Revisão dos relatórios especializados das perícias solicitadas ao especialista em neurologia, com identificação dos diagnósticos finais dos 108 pacientes encaminhados para avaliação. RESULTADOS: Os diagnósticos mais comuns em ordem decrescente de frequência foram: epilepsia, doenças reumatológicas, distúrbios psiquiátricos, alterações neurológicas associadas a alcoolismo crônico, síndrome pós TCE e doença vascular cerebral. CONCLUSÕES: Doenças neurológicas podem determinar importante grau de incapacidade no trabalhador catarinense. Contudo, existe um subestimado potencial de recuperação funcional. Além disso, diversas condições não genuinamente neurológicas são encaminhadas para avaliação especializada.OBJECTIVE: To present the most frequent diagnosis among patients refered for neurological evaluation to estimate their labour capacities at the unit of National Institute of Social Security (INSS, Florianópolis-SC, southern Brazil. METHOD: Review of all medical records of 108 patients evaluated between October 97 and May 98. The sample was submited to judicious medico-legal assessment to define their final diagnosis. RESULTS: Neurological evaluation disclosed as the commonest disorders, in decreasing order of frequency: epilepsy, rheumatic diseases, psychiatric illnesses, neurological disorders related to chronic alcoholism, head trauma syndrome and cerebrovascular diseases. CONCLUSION: Neurological disorders may be responsible for important disability among workers in our society. However, the potential for social rehabilitation, often underestimated, must be considered. Moreover, diverse non-neurological conditions used to be sent for

  4. CURRENT PRACTICES AND MEDICO-LEGAL ASPECTS OF PRE ...

    African Journals Online (AJOL)

    hi-tech

    2004-07-01

    Jul 1, 2004 ... Lecturer 1, Faculty of Law and S. Mohammed, MBBS., Resident Doctor, Department of Community Health, University of ... Over a hundred respondents were not informed of risk of procedure. .... requires patient's capacity, adequate disclosure of ... dealing with cases requiring major surgical procedures.

  5. special article the medico-legal prerequisite for initiating quarantine

    African Journals Online (AJOL)

    1Department of Biological, Environmental and Occupational Health Science, School of Public Health, Univer- ... and isolation in public health emergency management. ... The implementation of quarantine or isolation ... ety, technological systems within a given population ..... Ghana Civil Aviation Act, 2004 (Act 678).

  6. Medico-legal claims against English radiologists: 1995–2006

    Science.gov (United States)

    Halpin, S F S

    2009-01-01

    A list of claims against radiologists from 1995–2006 was obtained from the NHS Litigation Authority. It shows a total of 440 claims. The largest number of claims (199) related to delayed or missed diagnoses of cancer, and 73 claims related to breast radiology. There is a trend for a mild increase in the number of claims each year. 30 claims were made after a false-positive diagnosis of cancer. Just under £8.5 million has so far been paid in damages, with a further £5 million in legal fees. A claim for multiple missed diagnoses of breast cancer led to a pay-out of £464 000 (£673 000 after legal fees); the largest sum awarded following a delay in the diagnosis of an individual cancer was £300 000. The subtle legal distinction between error and negligence is reviewed here. The reason why breast radiologists are more likely to be sued than any other type of British radiologist is also discussed, along with the implications for UK radiological practice, particularly in light of the recent Chief Medical Officer's report on revalidation. A method is proposed that may protect radiologists from allegations of clinical negligence in the future. PMID:19470570

  7. Medico-legal claims against English radiologists: 1995-2006.

    Science.gov (United States)

    Halpin, S F S

    2009-12-01

    A list of claims against radiologists from 1995-2006 was obtained from the NHS Litigation Authority. It shows a total of 440 claims. The largest number of claims (199) related to delayed or missed diagnoses of cancer, and 73 claims related to breast radiology. There is a trend for a mild increase in the number of claims each year. 30 claims were made after a false-positive diagnosis of cancer. Just under pound8.5 million has so far been paid in damages, with a further pound5 million in legal fees. A claim for multiple missed diagnoses of breast cancer led to a pay-out of pound464 000 ( pound673 000 after legal fees); the largest sum awarded following a delay in the diagnosis of an individual cancer was pound300 000. The subtle legal distinction between error and negligence is reviewed here. The reason why breast radiologists are more likely to be sued than any other type of British radiologist is also discussed, along with the implications for UK radiological practice, particularly in light of the recent Chief Medical Officer's report on revalidation. A method is proposed that may protect radiologists from allegations of clinical negligence in the future.

  8. Aesthetic Dental Procedures: Legal and Medico-legal Implications.

    Science.gov (United States)

    Di Lorenzo, Pierpaolo; Casella, Claudia; Capasso, Emanuele; Delbon, Paola; Fedeli, Piergiorgio; Policino, Fabio; Niola, Massimo

    2018-01-01

    Dental treatments, as well as simple anatomical and functional repair work, can also be for aesthetic purposes. This is because the anatomical area concerned, i.e. the oral cavity, has a great power of attraction. Aesthetic treatments in general - in particular dental treatments - have been on the rise in recent years, and this has also meant an increase in claims due to patient dissatisfaction with the results obtained. Numerous laws have been introduced that emphasise the need for comprehensive prior information in order to acquire valid consent. This has resulted in the elimination of the distinction between the obligation of means and obligation of result, with achievement of the normally expected result required in any case.

  9. Computed tomography in dental implantology: medico-legal implications.

    Science.gov (United States)

    Scribano, Emanuele; Ascenti, Giorgio; Mazziotti, Silvio; Blandino, Alfredo; Racchiusa, Silvio; Gualniera, Patrizia

    2003-01-01

    Diagnostic imaging plays an important role in both the planning of dental implants and the follow-up evaluation of the procedure. It is widely known that computed tomography (CT) together with Dentascan software is the most accurate imaging technique in the planning of implant treatment. Unlike conventional radiological techniques, CT enables the three-dimensional evaluation of the bone without the overlapping of adjacent structures, as well as a precise measurement of the bone tissue available in the future implant site, contributing in this way to a significant reduction in unsuccessful treatment. CT also enables a qualitative evaluation of the bone structure together with a precise definition of the adjacent anatomical structures and possible associated pathologies. Finally, given the wealth of information provided by CT, it is clear that the technique can also be used for judging in retrospect the correctness of a dental implant procedure. The present paper describes the CT findings that are most relevant to the medicolegal assessment of professional liability in implantology.

  10. Page | 1 MEDICO-LEGAL EXAMINATION OF BIOLOGICAL ...

    African Journals Online (AJOL)

    Fr. Ikenga

    what triggers sexual arousal and the responses of both male and female to ... Keywords: Biological responses, Sexual Stimulation, Rape, Defence of Provocation, Criminal Law, ..... it all control over his emotions and action but also that, that feeling had an ... It is that which arouses, moves, calls forth, causes or occasions.

  11. Doctors and Medico Legal Examination of Victims of Sexual Offenses

    OpenAIRE

    Khan MK

    2015-01-01

    This increasing incident of crime against woman is adding up to the number of female patients. This, along with normal female patients there is a dire emergency in the treatment of female victims of sexual assault. We need provision in our hospital set up to treat the victims separately. There is also an awareness campaign against the sexual crimes and the right of women. Thus increasing trend of crime against woman in India is also burdening the health system in providing treatment and me...

  12. Medico-legal documentation South African Police Services forms

    African Journals Online (AJOL)

    be overly time consuming, and they may also feel intimidated ... practitioner to achieve this is by proper examination of victims and/or ... able to prove that it was safe for the patient to be observed in .... suspicion thereof with respect to a mentally disabled person, ... except for the right to know the human immunodeficiency.

  13. Medico-legal documentation of rape or sexual assault: are ...

    African Journals Online (AJOL)

    L Fouché

    Results: A response rate of 59.3% was achieved. ... on how to manage alleged rape or sexual assault cases, only 11.4% of the participants had hands-on exposure to an ..... atrocious crimes, constituting a huge human rights violation and.

  14. The ethical and medico-legal issues of trauma care

    African Journals Online (AJOL)

    the case of polytrauma, the patient's autonomy is further reduced. In addition, the risk .... Rational resource use in these circumstances has been an ac- cepted part of ... The high prevalence of HIV among the trauma population is well known in ...

  15. Medico-legal analysis of a case of mass shooting.

    Science.gov (United States)

    Kuruc, R; Šidlo, J; Zummerová, A; Šikuta, J; Baloghová, A

    Despite the existence of organised crime in Slovakia, no case has ever been monitored in which one individual used a firearm against several people, as happens in the U.S. or in Western Europe. The aim of this work is to demonstrate a "unique" case in the history of Slovak criminality, when six members of one family were killed and some other accidental victims were wounded or even killed by one perpetrator using a firearm.

  16. CAUSES OF SUDDEN NATURAL DEATH: A MEDICO-LEGAL ...

    African Journals Online (AJOL)

    89 No. 10 October 2012 ... The age range of the cases was 19-105 years with a mean age ... majority of cases (39.3%), the cause of death was related to the cardio-vascular ... Six hundred and twenty six cases of sudden natural .... (39/60) and a mean age of 54.2±15years. ..... D. A population-based autopsy study of sudden,.

  17. Childhood and adolescent fatalities at the Pretoria Medico-Legal ...

    African Journals Online (AJOL)

    in children <12 years, found the leading external cause of death to be road traffic fatalities (22% of cases). In Nigeria, Nwafor et al.[9] reviewed deaths in children ≤14 years; in a 20-year period, road traffic accidents ..... We thank Ms B English,.

  18. The use of propofol by gastroenterologists: medico-legal issues.

    Science.gov (United States)

    Axon, Andrew E

    2010-01-01

    The increasing use of non-anesthesiologist-administered propofol for sedation during gastrointestinal endoscopy has both clinical and legal consequences. As medical practices develop, the law of clinical negligence will be applied in the context of such developments. While the law will recognize the desirability of advanced techniques and methods, in circumstances where an injury or adverse outcome occurs, the facts of a particular case will be scrutinized to determine whether or not the duty of care between patient and clinician has been breached. This paper considers a number of specific matters likely to arise in the context of a clinical negligence/malpractice claim resulting from the use of non-anesthesiologist-administered propofol, in particular the role and standard of care expected of gastroenterologist and/or anesthetic provider, the relevance of FDA labeling, the implementation and use of protocols, the importance of patient selection and informed consent. Copyright 2010 S. Karger AG, Basel.

  19. [The flexible fiberoptic bronchoscopy report: medico-legal issues].

    Science.gov (United States)

    Trosini-Désert, V; Morin, J-M; Fournier, C; Similowski, T; Vergnon, J-M

    2010-09-01

    The flexible bronchoscopy report is one of the tools permitting exchange of medical information in respiratory medicine and is an integral part of the medical record. Currently, there is no consensus on its content, and consequently, there are no recommendations. A survey was carried out involving experts from the Groupe d'Endoscopie de Langue Française (GELF--Endoscopy Research Group of the French Language Society of Pneumology) and a lawyer from the legal affairs and patient's rights department of the Paris public hospital system. Thirty-four questions distributed in eight chapters were asked in an eight-part questionnaire covering: 1) general administration, 2) environmental safety, 3) medical and anatomical description of the examination, 4) tolerance/complications of the examination, 5) conclusion, 6) image and video sequence capture, 7) administrative data for archiving, 8) disposable elements used during the examination. The results showed as many areas of convergence as they did divergence, between physicians, and between physicians and lawyer. Collective consideration is required to harmonize the writing of bronchoscopy reports, to provide a tool that is not only consensual and complete, but also valid and sound from the medicolegal viewpoint. Copyright © 2010 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  20. Editorial: Medico-legal Litigation: Balancing Spiralling Costs with ...

    African Journals Online (AJOL)

    South African Journal of Bioethics and Law. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 8, No 1 (2015) >. Log in or Register to get access to full text downloads.

  1. Effect of the insulation materials filling on the thermal performance of sintered hollow bricks under the air-conditioning intermittent operation

    Directory of Open Access Journals (Sweden)

    Chaoping Hou

    2018-06-01

    Full Text Available Wall insulation performance is an important factor affecting building energy consumption and indoor comfortable level. This study proposes that the insulation materials are filled into the cavities of the sintered hollow brick to replace the single insulation layer. The physical models of typical walls were built by the hollow bricks filled with expanding polystyrene board (EPS in cavities and wall thermal performance is numerically analyzed by the Finite Volume Method under air-conditioning intermittent operation, which conforms to the actual operation rules of air-conditioning. Results show that filling EPS in cavities is beneficial to improve the thermal performance of the bricks, and the larger the EPS filling ratio, the higher the thermal performance improvement. The EPS filling ratio increase has the higher sensitivity on inner surface heat flow under the low EPS filling ratio, and filling EPS in the external cavities is optimum with the decrement rate 5.92% higher than filling EPS in internal cavities for the EPS filling ratio of 20%, while filling EPS in internal and external cavities simultaneously is optimum with decrement rate 2.45%–6.87% higher than that with filling EPS in the internal cavities for the EPS filling ratio of 40%–80%. Keywords: Insulation filling ratio, Insulation filling location, Thermal performance, Sintered hollow bricks

  2. Sealing ability of a new polydimethylsiloxane-based root canal filling material

    NARCIS (Netherlands)

    Özok, A.R.; van der Sluis, L.W.M.; Wu, M.K.; Wesselink, P.R.

    2008-01-01

    We tested the null hypothesis that there is no difference in the sealing ability of GuttaFlow, RoekoSeal, and AH26 in root canals. Sixty extracted mandibular premolars were filled with AH26 (lateral compaction), RoekoSeal, or GuttaFlow (modified single-cone). The sealing ability of the root canal

  3. Sealing ability of a new polydimethylsiloxane-based root canal filling material

    NARCIS (Netherlands)

    Ozok, Ahmet R.; van der Sluis, Lucas W. M.; Wu, Min-Kai; Wesselink, Paul R.

    We tested the null hypothesis that there is no difference in the sealing ability of GuttaFlow, RoekoSeal, and AH26 in root canals. Sixty extracted mandibular premolars were filled with AH26 (lateral compaction), RoekoSeal, or GuttaFlow (modified single-cone). The sealing ability of the root canal

  4. Distribution of anthropogenic fill material within the Y-12 plant area, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Sutton, G.E. Jr.; Field, S.M.

    1995-10-01

    Widespread groundwater contamination in the vicinity of the Oak Ridge Y-12 Plant has been documented through a variety of monitoring efforts since the late 1970s. Various contaminants, most notably volatile organic compounds (VOCs), have migrated through the subsurface and formed extensive contaminant plumes within the Knox Aquifer/Maynardville Limestone, the primary exit pathway for groundwater transport within the Bear Creek Valley. In 1991, an integrated, comprehensive effort (Upper East Fork Poplar Creek [UEFPC] Phase I monitoring network) was initiated in order to (1) identify contaminant source areas within the industrialized portions of the plant and (2) define contamination migration pathways existing between the source areas and the Knox Aquifer/Maynardville Limestone. Data obtained during previous studies have indicated that extensive zones of fill and buried utility trenches may serve as preferred migration pathways. In addition, portions of UEFPC were rerouted, with several of its tributaries being filled during the initial construction of the plant. These filled surface drainage features are also believed to serve as preferred migration pathways. The identification of preferred contaminant migration pathways within the Y-12 Plant area is essential and required to refine the current Bear Creek Valley groundwater conceptual model and to assist in the selection of technically feasible and cost effective remedial strategies. This report presents the results of an initial investigation of the occurrence of manmade (anthropogenic) fill and its effect upon groundwater movement within the plant area. These interpretations are subject to revision and improvement as further investigation of the effects of the fill upon contaminant migration progresses

  5. Analysis of Material Removal and Surface Characteristics in Machining Multi Walled Carbon Nanotubes Filled Alumina Composites by WEDM Process

    Directory of Open Access Journals (Sweden)

    Annebushan Singh Meinam

    2017-01-01

    Full Text Available The reinforcement of ceramic materials with electrically conductive particles increases the overall conductivity of the ceramic material. This allows the ceramic material to be more readily machined using wire electrical discharge machining process. The current work is an approach to identify the machinability of multi walled carbon nanotubes filled alumina composites in wire electrical discharge machining process. Alumina samples of 5 vol. % and 10 vol. % multi walled carbon nanotubes are machined and analysed for material removal rate and the surface characteristics. An increase in material removal rate is observed with increase in filler concentrations. At the same time, better surface roughness is observed. The surface characteristics of composite alumina are further compared with Monel 400 alloy. It has been observed that spalling action is the dominating material removal mechanism for alumina composites, while melting and evaporation is for the Monel 400 alloy.

  6. Sealing ability of MTA, CPM, and MBPc as root-end filling materials: a bacterial leakage study.

    Science.gov (United States)

    Medeiros, Paulo Leal; Bernardineli, Norberti; Cavenago, Bruno Cavalini; Torres, Sérgio Aparecido; Duarte, Marco Antonio Hungaro; Bramante, Clovis Monteiro; Marciano, Marina Angélica

    2016-04-01

    Objectives To evaluate the sealing ability of three root-end filling materials (white MTA, CPM, and MBPc) using an Enterococcus faecalis leakage model. Material and Methods Seventy single-root extracted human teeth were instrumented and root-ends were resected to prepare 3 mm depth cavities. Root-end preparations were filled with white MTA, CPM, and MBPc cements. Enterococcus faecalis was coronally introduced and the apical portion was immersed in BHI culture medium with phenol red indicator. The bacterial leakage was monitored every 24 h for 4 weeks. The statistical analysis was performed using the Wilcoxon-Gehan test (pCPM and the other groups. Conclusions The epoxy resin-based cement MBPc had lower bacterial leakage compared with the calcium silicate-based cements MTA and CPM.

  7. Comparison of antibacterial activities of root-end filling materials by an agar diffusion assay and Alamar blue assay

    Directory of Open Access Journals (Sweden)

    Tsui-Hsien Huang

    2012-12-01

    Conclusion: We concluded that both the agar diffusion test and Alamar blue assay gave comparable findings of assessing the antimicrobial activity present in root-end filling materials. No antimicrobial activity was detected for mineral trioxide aggregate, calcium silicate cement, or amalgam after coming into contact with S. mutans, S. sanguinis and E. coli. IRM showed high antimicrobial activity against both S. sanguinis and E. coli.

  8. Characterisation of bentonites from Kutch, India and Milos, Greece - some candidate tunnel back-fill materials?

    International Nuclear Information System (INIS)

    Olsson, Siv; Karnland, Ola

    2009-12-01

    During the past decades comprehensive investigations have been made on bentonite clays in order to find optimal components of the multi-barrier system of repositories for radioactive waste. The present study gives a mineralogical characterisation of some selected bentonites, in order to supply some of the necessary background data on the bentonites for evaluating their potential as tunnel back-fill materials. Two bentonites from the island of Milos, Greece (Milos BF 04 and BF 08), and two bentonites from Kutch, India (Kutch BF 04 and BF 08) were analysed for their grain size distribution, cation exchange properties and chemical composition. The mineralogical composition was determined by X-ray diffraction analysis and evaluated quantitatively by use of the Siroquant software. Both the bulk bentonite and the 63 μm. The bentonite is distinguished by a high content of dolomite and calcite, which make up almost 25% of the bulk sample. The major accessory minerals are K-feldspars and plagioclase, whereas the content of sulphur-bearing minerals is very low (0.06% total S). Smectite makes up around 60% of the bulk sample, which has a CEC value of 73 meq/100 g. The pool of interlayer cations has a composition Mg>Ca>>Na>>K. The X-ray diffraction characteristics and the high potassium content (1.03% K 2 O) of the Na>Mg>>K. The 2 O) which indicates that also this smectite may be interstratified with a few percent illitic layers. Based on the charge distribution the smectite should be classified as montmorillonite but in this case Fe predominates over Mg in the octahedral sheet. The structural formula suggests that this smectite has the lowest total layer charge of the smectites examined. Kutch BF 04 contains essentially no particles >63 μm. The bentonite has a high content of titanium and iron-rich accessory minerals, such as anatase, magnetite, hematite and goethite. Other accessory minerals of significance are feldspars and quartz, whereas the content of sulphur

  9. Effect of ultrasonic agitation on push-out bond strength and adaptation of root-end filling materials.

    Science.gov (United States)

    Alcalde, Murilo Priori; Vivan, Rodrigo Ricci; Marciano, Marina Angélica; Duque, Jussaro Alves; Fernandes, Samuel Lucas; Rosseto, Mariana Bailo; Duarte, Marco Antonio Hungaro

    2018-05-01

    This study evaluated the effect of ultrasonic agitation of mineral trioxide aggregate (MTA), calcium silicate-based cement (CSC), and Sealer 26 (S26) on adaptation at the cement/dentin interface and push-out bond strength. Sixty maxillary canines were divided into 6 groups ( n = 10): MTA, S26, and CSC, with or without ultrasonic activation (US). After obturation, the apical portions of the teeth were sectioned, and retrograde cavities were prepared and filled with cement by hand condensation. In the US groups, the cement was activated for 60 seconds: 30 seconds in the mesio-distal direction and 30 seconds in the buccal-lingual direction, using a mini Irrisonic insert coupled with the ultrasound transducer. After the materials set, 1.5-mm thick sections were obtained from the apexes. The presence of gaps and the bond between cement and dentin were analyzed using low-vacuum scanning electron microscopy. Push-out bond strength was measured using a universal testing machine. Ultrasonic agitation increased the interfacial adaptation of the cements. The S26 US group showed a higher adaptation value than MTA ( p < 0.05). US improved the push-out bond strength for all the cements ( p < 0.05). The US of retrograde filling cements enhanced the bond to the dentin wall of the root-end filling materials tested.

  10. MoS2-Filled PEEK Composite as a Self-Lubricating Material for Aerospace Applications

    Science.gov (United States)

    Theiler, Geraldine; Gradt, Thomas

    2010-01-01

    At BAM, several projects were conducted in the past years dealing with the tribological properties of friction couples at cryogenic temperature and in vacuum environment. Promising candidates for vacuum application are MoS2-filled PEEK/PTFE composites, which showed a friction coefficient as low as 0.03 in high vacuum. To complete the tribological profile of these composites, further tests were performed in ultra-high vacuum (UHV) at room temperature. In this paper, friction and stick slip behavior, as well as outgassing characteristics during the test are presented.

  11. Effectiveness of the ProTaper Universal Retreatment™ system for removing a 10-year-old filling material.

    Science.gov (United States)

    Aguiar, C; Bernart, F; Lima, G; Câmara, A

    2012-01-01

    The aim of the present study was to evaluate the effectiveness of the ProTaper Universal Retreatment™ system and the manual technique for removing a 10-year-old filling material. Twenty mesiobuccal canals of mandibular first molars with curvature degrees ranging from 20° to 35° were instrumented by the Double-Flared Instrumentation Technique with the NitiFlex files. The root canals were dried with sterile paper points and filled with gutta-percha and a zinc oxide-eugenol-based sealer using a cold lateral condensation technique. Accesses to the cavities were temporarily sealed with Cavit. The teeth were embedded in gauze containing saline solution, which was renewed every 2 weeks, and were stored at 37 °C in 100% humidity for 10 years. Buccolingual and mesiodistal radiographs were taken to evaluate the quality of the root canal filling. The radiographs were mounted in slide frames to allow them to be evaluated by the three examiners, who were specialists in endodontics. Only the specimens in whom there was agreement between the three evaluators were included in the study. The specimens were divided into 2 groups with 10 root canals each, according to gutta-percha removal techniques: Group 1: ProTaper Universal Retreatment™ system; Group 2: Hedström and K-files. Buccolingual and mesiodistal radiographs were taken and evaluated by three examiners who determined the effectiveness of the removal of the filling material. The presence of material was measured according to a score scale. Data were analyzed statistically by Fisher's exact test at 5% significance level. There were no statistical differences between the two methods in the coronal (P=0.211), and middle (P=0.266) thirds, but there were statistical differences between the two methods in the apical third (P=0.038). Not one of the experimental techniques promoted complete removal of the filling materials. The manual technique with K-file and Hedström files achieved better results than the Pro

  12. Characterisation of bentonites from Kutch, India and Milos, Greece - some candidate tunnel back-fill materials?

    Energy Technology Data Exchange (ETDEWEB)

    Olsson, Siv; Karnland, Ola (Clay Technology AB, Lund (Sweden))

    2009-12-15

    During the past decades comprehensive investigations have been made on bentonite clays in order to find optimal components of the multi-barrier system of repositories for radioactive waste. The present study gives a mineralogical characterisation of some selected bentonites, in order to supply some of the necessary background data on the bentonites for evaluating their potential as tunnel back-fill materials. Two bentonites from the island of Milos, Greece (Milos BF 04 and BF 08), and two bentonites from Kutch, India (Kutch BF 04 and BF 08) were analysed for their grain size distribution, cation exchange properties and chemical composition. The mineralogical composition was determined by X-ray diffraction analysis and evaluated quantitatively by use of the Siroquant software. Both the bulk bentonite and the <1mum fraction were analyzed when relevant. Prior to the chemical analyses the <1 mum fractions were converted to homo-ionic clays and purified by dialysis. The chemical data were used for calculating the structural formula of the smectites. Milos BF 04 contains ca. 10% particles >63 mum. The bentonite is distinguished by a high content of dolomite and calcite, which make up almost 25% of the bulk sample. The major accessory minerals are K-feldspars and plagioclase, whereas the content of sulphur-bearing minerals is very low (0.06% total S). Smectite makes up around 60% of the bulk sample, which has a CEC value of 73 meq/100 g. The pool of interlayer cations has a composition Mg>Ca>>Na>>K. The X-ray diffraction characteristics and the high potassium content (1.03% K{sub 2}O) of the <1 mum fraction suggest that the smectite is interstratified with ca. 10% illitic layers. Based on the charge distribution the smectite should be classified as montmorillonite and according to the structural formula, Mg predominates over Fe in the octahedral sheet. However, remnants of Mg-carbonates, if present, may be a source of error in the formula calculation. Milos BF 08 has a

  13. Healing process following application of set or fresh mineral trioxide aggregate as a root-end filling material.

    Science.gov (United States)

    Habibi, Mehdi; Ghoddusi, Jamileh; Habibi, Ataollah; Mohtasham, Nooshin

    2011-01-01

    An unsuccessful attempt to reach the apical area or to place the retrograde material is a major difficulty in periradicular surgery. The aim of this study was to compare the histological evaluation of the healing process following an orthograde versus a retrograde application of mineral trioxide aggregate (MTA) as a root-end filling material during apical surgery on cats' teeth in order to find out whether orthograde placement of MTA before surgery can be used instead of retrograde placement during surgery. In this experimental study, 24 canine teeth in 12 mature and healthy cats were filled with either MTA or gutta-percha in an orthograde manner. Two weeks later, the teeth with MTA were surgically exposed and resected to the set-MTA within the canals. The teeth previously filled by gutta-percha were also surgically exposed, and retrograde cavities were prepared at the root ends and filled with fresh-MTA. After 8 weeks, the animals were euthanized by vital perfusion. Six-micron histological slices were prepared from samples, stained by Hematoxylin & Eosin, and histologically studied by means of a light microscope. The collected data was analyzed by the Chi-square and the T-test. One of the samples in the fresh-MTA group was omitted during processing because of inappropriate sectioning. In the set-MTA group, 5 out of 12 showed chronic abscess, while in the fresh-MTA group, 2 out of 11 were discovered to have chronic abscess; however, no significant difference was observed (P>.05). Hard tissue healing (cementum, bone, cementum + bone formation) in the set-MTA and fresh-MTA groups were 7 out of 12 and 9 out of 11, respectively. While healing seemed more likely to occur in the fresh-MTA group, the difference was statistically insignificant (P>.05). The magnitude of bone, cementum, or bone and cementum formation showed slight differences between the two groups; however, the figures failed to show any marked differences (P>.05). Orthograde placement of MTA could be used

  14. Entropy generation in Poiseuille flow through a channel partially filled with a porous material

    Directory of Open Access Journals (Sweden)

    Kumar Vikas

    2015-01-01

    Full Text Available In the present paper, a theoretical analysis of entropy generation due to fully developed flow and heat transfer through a parallel plate channel partially filled with a porous medium under the effect of transverse magnetic field and radiation is presented. Both horizontal plates of the channel are kept at constant and equal temperature. An exact solution of governing equation for both porous and clear fluid regions has been obtained in closed form. The entropy generation number and the Bejan number are also calculated. The effects of various parameters such as magnetic field parameter, radiation parameter, Brinkman number, permeability parameter, ratios of viscosities and thermal conductivities are examined on velocity, temperature, entropy generation rate.

  15. Glucose reactivity with filling materials as a limitation for using the glucose leakage model

    NARCIS (Netherlands)

    Shemesh, H.; Souza, E.M.; Wu, M.K.; Wesselink, P.R.

    2008-01-01

    Aim To evaluate the reactivity of different endodontic materials and sealers with glucose and to asses the reliability of the glucose leakage model in measuring penetration of glucose through these materials. Methodology Ten uniform discs (radius 5 mm, thickness 2 mm) were made of each of the

  16. Computerized simulation of the mechanical behavior of wood-filled shock absorbers of radioactive materials transport casks

    International Nuclear Information System (INIS)

    Neumann, Martin; Wille, Frank

    2011-01-01

    In Germany the mechanical component inspection of transport containers for radioactive materials is performed by BAM (Bundesanstalt fuer Materialforschung und -pruefung) under consideration of national and international standards and guidelines. Experimental and calculative (analytical and numerical) techniques combined with material and/or component testing are the basis of assessment concepts according the state of the art. The authors describe the experiences of BAM concerning assessment and description of the mechanical behavior of shock absorbing components, including modeling strategies, material models, drop tests and experiment-calculation comparison. Energy absorbing components are used to reduce the impact forces at the container in case of a transport accident. In Germany wood filled thin-walled constructions are used. The deformation behavior of the wood is a main part of the calculative simulation procedures in comparison with experimental tests.

  17. Microbial leakage of MTA, Portland cement, Sealapex and zinc oxide-eugenol as root-end filling materials.

    Science.gov (United States)

    Estrela, Carlos; Estrada-Bernabé, Pedro-Felício; de Almeida-Decurcio, Daniel; Almeida-Silva, Julio; Rodrigues-Araújo-Estrela, Cyntia; Poli-Figueiredo, José-Antonio

    2011-05-01

    The aim of this study was to compare the microbial leakage of mineral trioxide aggregate (MTA), Portland cement (PC), Sealapex and zinc oxide-eugenol (ZOE) as root-end filling materials. An in vitro microbial leakage test (MLT) with a split chamber was used in this study. A mixture of facultative bacteria and one yeast (S. aureus+E. faecalis+P. aeruginosa+B. subtilis+C. albicans) was placed in the upper chamber and it could only reach the lower chamber containing Brain Heart Infusion broth by way of leakage through the root-end filling. Microbial leakage was observed daily for 60 days. Sixty maxillary anterior human teeth were randomly assigned to different groups--MTA and PC (gray and white), Sealapex+zinc oxide and ZOE, control groups and subgroups to evaluate the influence of EDTA for smear layer removal. These materials were further evaluated by an agar diffusion test (ADT) to verify their antimicrobial efficacy. Data were analyzed statistically by Kruskal-Wallis and Mann-Whitney test. In the MLT, Sealapex+zinc oxide and ZOE did not show evidence of microbial leakage over the 60-day experimental period. The other materials showed leakage from the 15th day. The presence of smear layer influenced microbial leakage. Microbial inhibition zones were not observed in all samples tested by ADT. Sealapex+zinc oxide and ZOE did not show microbial leakage over the experimental period, whereas it was verified within 15 to 45 days in MTA and Portland cement.

  18. Wide band design on the scaled absorbing material filled with flaky CIPs

    Science.gov (United States)

    Xu, Yonggang; Yuan, Liming; Gao, Wei; Wang, Xiaobing; Liang, Zichang; Liao, Yi

    2018-02-01

    The scaled target measurement is an important method to get the target characteristic. Radar absorbing materials are widely used in the low detectable target, considering the absorbing material frequency dispersion characteristics, it makes designing and manufacturing scaled radar absorbing materials on the scaled target very difficult. This paper proposed a wide band design method on the scaled absorbing material of the thin absorption coating with added carbonyl iron particles. According to the theoretical radar cross section (RCS) of the plate, the reflection loss determined by the permittivity and permeability was chosen as the main design factor. Then, the parameters of the scaled absorbing materials were designed using the effective medium theory, and the scaled absorbing material was constructed. Finally, the full-size coating plate and scaled coating plates (under three different scale factors) were simulated; the RCSs of the coating plates were numerically calculated and measured at 4 GHz and a scale factor of 2. The results showed that the compensated RCS of the scaled coating plate was close to that of the full-size coating plate, that is, the mean deviation was less than 0.5 dB, and the design method for the scaled material was very effective.

  19. Thermal Protection Performance of Carbon Aerogels Filled with Magnesium Chloride Hexahydrate as a Phase Change Material

    Directory of Open Access Journals (Sweden)

    Ali Kazemi

    2014-02-01

    Full Text Available Carbon aerogels are comprised of a class of low density open-cell foams with large void space, nanometer pore size and composed of sparsely semi-colloidal nanometer sized particles forming an open porous structure. Phase change materials are those with high heat of fusion that could absorb and release a large amount of energy at the time of phase transition. These materials are mostly used as thermal energy storage materials but in addition they could serve as an obstacle for passage of heat during phase changes and this has led to their use in thermal protection systems. In this study, the effect of magnesium chloride hexahydrate, as a phase change material (melting point 115°C, on thermal properties of carbon aerogels is investigated. Thermal performance tests are designed and used for comparing the temperature-time behavior of the samples. DSC is applied to obtain the latent heat of melting of the phase change materials and the SEM tests are used to analyze the microstructure and morphology of carbon aerogels. The results show that the low percentage of phase change materials in carbon aerogels does not have any significant positive effect on carbon aerogels thermal properties. However, these properties are improved by increasing the percentage of phase change materials. With high percentage of phase change materials, a sample surface at 300°C would display an opposite surface with a significant drop in temperature increases, while at 115-200°C, with carbon aerogels, having no phase change materials, there is a severe reduction in the rate of temperature increase of the sample.

  20. Algal growth inhibition test in filled, closed bottles for volatile and sorptive materials

    DEFF Research Database (Denmark)

    Mayer, Philipp; Nyholm, Niels; Verbruggen, Eric M. J.

    2000-01-01

    Exposure concentrations of many hydrophobic substances are difficult to maintain in algal growth inhibition tests performed in open agitated flasks. This is partly because such compounds tend to volatilize from aqueous solution and partly because of sorption to the algal biomass as well as to the......Exposure concentrations of many hydrophobic substances are difficult to maintain in algal growth inhibition tests performed in open agitated flasks. This is partly because such compounds tend to volatilize from aqueous solution and partly because of sorption to the algal biomass as well......, and the resulting dissolved CO2 concentration supported maximum algal growth rates without pH drift for algal densities up to 4 mg dry weight/L. Two-day toxicity tests with kerosene were performed with this new test design and compared with an open bottle test and with a closed bottle test with headspace. Exposure...... concentrations of the volatile fraction of kerosene decreased by 99% in the open test, by 77% in the closed flask test with headspace, and by 16% in the filled closed bottle test. Algal growth inhibition was observed at much lower additions of kerosene in the new test design because of the improved maintenance...

  1. Systematic review of "filling" procedures for lip augmentation regarding types of material, outcomes and complications.

    Science.gov (United States)

    San Miguel Moragas, Joan; Reddy, Rajgopal R; Hernández Alfaro, Federico; Mommaerts, Maurice Y

    2015-07-01

    The ideal lip augmentation technique provides the longest period of efficacy, lowest complication rate, and best aesthetic results. A myriad of techniques have been described for lip augmentation, but the optimal approach has not yet been established. This systematic review with meta-regression will focus on the various filling procedures for lip augmentation (FPLA), with the goal of determining the optimal approach. A systematic search for all English, French, Spanish, German, Italian, Portuguese and Dutch language studies involving FPLA was performed using these databases: Elsevier Science Direct, PubMed, Highwire Press, Springer Standard Collection, SAGE, DOAJ, Sweetswise, Free E-Journals, Ovid Lippincott Williams & Wilkins, Willey Online Library Journals, and Cochrane Plus. The reference section of every study selected through this database search was subsequently examined to identify additional relevant studies. The database search yielded 29 studies. Nine more studies were retrieved from the reference sections of these 29 studies. The level of evidence ratings of these 38 studies were as follows: level Ib, four studies; level IIb, four studies; level IIIb, one study; and level IV, 29 studies. Ten studies were prospective. This systematic review sought to highlight all the quality data currently available regarding FPLA. Because of the considerable diversity of procedures, no definitive comparisons or conclusions were possible. Additional prospective studies and clinical trials are required to more conclusively determine the most appropriate approach for this procedure. IV. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Castor oil polyurethane containing silica nanoparticles as filling material of bone defect in rats.

    Science.gov (United States)

    Nacer, Renato Silva; Poppi, Rodrigo Ré; Carvalho, Paulo de Tarso Camilo de; Silva, Baldomero Antonio Kato da; Odashiro, Alexandre Nakao; Silva, Iandara Schettert; Delben, José Renato Jurkevicz; Delben, Angela Antonia Sanches Tardivo

    2012-01-01

    To evaluate the biologic behavior of the castor polymer containing silica nanoparticles as a bone substitute in diafisary defect. Twenty seven male Rattus norvegicus albinus Wistar lineage were submitted to bone defect filled with castor oil polymer. Three experimental groups had been formed with nine animals each: (1) castor oil polymer containing only calcium carbonate; (2) castor oil polymer with calcium carbonate and doped with 5% of silica nanoparticles; (3) castor polymer with calcium carbonate doped with 10% of silica nanoparticles; 3 animals of each group were submitted to euthanasia 15, 30 and 60 days after experimental procedure, and their femurs were removed to histological evaluation. there was bone growth in all the studied groups, with a greater tendency of growth in the group 1. After 30 days all the groups presented similar results. After 60 days a greater amount of fibroblasts, osteoblasts, osteocytes and osteoclasts in group 3 was observed, with integrated activity of 3 kinds of cells involved in the bone activation-reabsorption-formation. The castor polymer associated to the silica nanoparticles is biocompatible and allows osteoconduction. The presence of osteoprogenitors cells suggests silica osteoinduction capacity.

  3. Hydration characteristics of zirconium oxide replaced Portland cement for use as a root-end filling material.

    Science.gov (United States)

    Camilleri, J; Cutajar, A; Mallia, B

    2011-08-01

    Zirconium oxide can be added to dental materials rendering them sufficiently radiopaque. It can thus be used to replace the bismuth oxide in mineral trioxide aggregate (MTA). Replacement of Portland cement with 30% zirconium oxide mixed at a water/cement ratio of 0.3 resulted in a material with adequate physical properties. This study aimed at investigating the microstructure, pH and leaching in physiological solution of Portland cement replaced zirconium oxide at either water-powder or water-cement ratios of 0.3 for use as a root-end filling material. The hydration characteristics of the materials which exhibited optimal behavior were evaluated. Portland cement replaced by zirconium oxide in varying amounts ranging from 0 to 50% in increments of 10 was prepared and divided into two sets. One set was prepared at a constant water/cement ratio while the other set at a constant water/powder ratio of 0.3. Portland cement and MTA were used as controls. The materials were analyzed under the scanning electron microscope (SEM) and the hydration products were determined. X-ray energy dispersive analysis (EDX) was used to analyze the elemental composition of the hydration products. The pH and the amount of leachate in Hank's balanced salt solution (HBSS) were evaluated. A material that had optimal properties that satisfied set criteria and could replace MTA was selected. The microstructure of the prototype material and Portland cement used as a control was assessed after 30 days using SEM and atomic ratio diagrams of Al/Ca versus Si/Ca and S/Ca versus Al/Ca were plotted. The hydration products of Portland cement replaced with 30% zirconium oxide mixed at water/cement ratio of 0.3 were calcium silicate hydrate, calcium hydroxide and minimal amounts of ettringite and monosulphate. The calcium hydroxide leached in HBSS solution resulted in an increase in the pH value. The zirconium oxide acted as inert filler and exhibited no reaction with the hydration by-products of Portland

  4. Evaluation of simulation learning materials use to fill the gap in Japanese dental English education.

    Science.gov (United States)

    Seki, Naoko; Moross, Janelle; Sunaga, Masayo; Hobo, Koki; Miyoshi, Tomoe; Nitta, Hiroshi; Kinoshita, Atsuhiro; Morio, Ikuko

    2016-01-01

    Even though English is most frequently the common language when the patient's native language differs from that of a dentist, the opportunities for Japanese undergraduate dental students to learn dental English are now quite limited. The purposes of our study were to investigate: the effectiveness and feasibility of the computer-assisted simulation materials as one solution strategy for dental English education in Japan, and the needs and demands for dental English from the learners' side. Interactive simulation materials for medical interviews in English and clinical cases which were translated to English, were delivered via Learning Management System (LMS) to nineteen trainee residents of dentistry (residents). Evaluation for the materials, learners' knowledge and interests in the contents, and ease of operation were obtained by post-questionnaire (response rates were 100% and 95%, respectively). Both questionnaire-surveys received positive feedback toward the materials, yet 47% answered that they lacked the level of knowledge about contents of the medical interview in English. Results were sufficient to suggest that the residents would like to have the opportunity to study or practice medical interview in English, or English related to dentistry, and that the simulation materials could be one of the solution strategies for opportunity provision.

  5. In vivo Evaluation of Marginal Microgaps of Sheep Incisors filled with Two Composite Materials

    Directory of Open Access Journals (Sweden)

    Mária Figurová

    2009-01-01

    Full Text Available The aim of the study was to evaluate the marginal microgaps of two light-induced polymerization composite materials: Filtek P60 (3M ESPE and Opticor New (Spofa Dental in ovine teeth in vivo. The restorative materials were placed to type A-cavity to buccal surfaces of permanent teeth (Triadan system 301, 302, 303, 401, 402, 403. The variables of composite materials were evaluated in 3 groups of animals, 2 animals in each, at different time intervals (1, 6 and 9 months after beginning of the experiment. In various time intervals, 12 teeth per group were extracted under general injection anaesthesia, 6 teeth from each animal. Altogether 36 teeth were extracted throughout the experiment. During the experiment we observed neither cracks nor marginal discoloration in both Filtek P60 and Opticor New restorations. Retention of all restorations was 100%. Significant (P = 0.029 ANOVA differences were observed in the dentin with Filtek P60 packable restorations which exhibited smaller marginal microgaps (OPTICOR NEW and dentin 11.09 mm, FILTEK P60 and dentin 5.64 μm. The mean size of microgaps between dentin and the packable composite material Filtek P60 was significantly lower (P = 0.029 ANOVA in comparison with the microhybrid Opticor New composite restorations. These materials are suitable as permanent restoration of dental cervical caries in sheep and other herbivores, such as those kept in zoological gardens and companion animals.

  6. Mechanical and thermal properties of hydroxyapatite filled poly(methyl methacrylate) heat processed denture base material

    International Nuclear Information System (INIS)

    Mohamed, S.H.; Arifin, A.; Mohd Ishak, Z.A.; Nizam, A.; Samsudin, A.R.

    2004-01-01

    The aim of this study was to evaluate the effect of powder-to-liquid ratio on the glass transition temperature (Tg) and the tensile properties of denture base material prepared from poly (methyl methacrylate) (PMMA) and hydroxyapatite (HA) previously treated with 3-trimethoxysilylpropyl methacrylate (γ-MPS). Specimens for, mechanical testing were prepared by adding composites powder (PMMA, BPO and RA) to the monomer (MMA and EGDMA) followed by hand mixing as in dental laboratory description usage. The glass transition temperature was studied by using differential scanning calorimetry (DSQ. It was observed that the tensile properties and the Tg were affected by the powder-to-liquid ratio. The mechanical characterization of the materials were performed by using single edge notch-tension (SEN-T) specimens; the fracture toughness was slightly higher in formulation which contained RA filler compared to commercial denture base material. (Author)

  7. 40 CFR 230.60 - General evaluation of dredged or fill material.

    Science.gov (United States)

    2010-07-01

    ... (previous tests, the presence of polluting industries and information about their discharge or runoff into... is most likely to be free from chemical, biological, or other pollutants where it is composed... industries, municipalities, or other sources, including types and amounts of waste materials discharged along...

  8. Cuspal deflection and microleakage in premolar teeth restored with bulk-fill flowable resin-based composite base materials

    DEFF Research Database (Denmark)

    Moorthy, A; Hogg, C H; Dowling, A H

    2012-01-01

    To assess the cuspal deflection and cervical microleakage of standardised Class II cavities incrementally filled with a dimethacrylate RBC or bulk-fill flowable RBC bases.......To assess the cuspal deflection and cervical microleakage of standardised Class II cavities incrementally filled with a dimethacrylate RBC or bulk-fill flowable RBC bases....

  9. Anisotropic local physical properties of human dental enamel in comparison to properties of some common dental filling materials.

    Science.gov (United States)

    Raue, Lars; Hartmann, Christiane D; Rödiger, Matthias; Bürgers, Ralf; Gersdorff, Nikolaus

    2014-11-01

    A major aspect in evaluating the quality of dental materials is their physical properties. Their properties should be a best fit of the ones of dental hard tissues. Manufacturers give data sheets for each material. The properties listed are characterized by a specific value. This assumes (but does not prove) that there is no direction dependence of the properties. However, dental enamel has direction-dependent properties which additionally vary with location in the tooth. The aim of this paper is to show the local direction dependence of physical properties like the elastic modulus or the thermal expansion in dental hard tissues. With this knowledge the 'perfect filling/dental material' could be characterized. Enamel sections of ∼400-500 μm thickness have been cut with a diamond saw from labial/buccal to palatal/lingual (canine, premolar and molar) and parallel to labial (incisor). Crystallite arrangements have been measured in over 400 data points on all types of teeth with x-ray scattering techniques, known from materials science. X-ray scattering measurements show impressively that dental enamel has a strong direction dependence of its physical properties which also varies with location within the tooth. Dental materials possess only little or no property direction dependence. Therefore, a mismatch was found between enamel and dental materials properties. Since dental materials should possess equal (direction depending) properties, worthwhile properties could be characterized by transferring the directional properties of enamel into a property 'wish list' which future dental materials should fulfil. Hereby the 'perfect dental material' can be characterized.

  10. Experimental evaluation and design of unfilled and concrete-filled FRP composite piles : Task 4B : material & construction specifications : final report.

    Science.gov (United States)

    2015-07-01

    The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP composite piles for load-bearing in bridges. This report covers Task 4B, Materials and Construction Specifications. : This technical report...

  11. Comparing ProFile Vortex to ProTaper Next for the efficacy of removal of root filling material: An ex vivo micro-computed tomography study

    Directory of Open Access Journals (Sweden)

    Emad AlShwaimi

    2018-01-01

    Conclusion: Our findings suggest that PV is as effective as PTN for removal of root canal filling material. Therefore, PV can be considered for use in endodontic retreatment, although more effective files or techniques are still required.

  12. Sealing ability of cermet ionomer cement as a retrograde filling material.

    Science.gov (United States)

    Aktener, B O; Pehlivan, Y

    1993-03-01

    An in vitro dye leakage study was performed to compare the sealing ability of high copper amalgam with cavity varnish and cermet ionomer cement with and without varnish when used as retrofilling materials. The root canals of 54 maxillary anterior teeth were instrumented and obturated with gutta-percha and sealer. The apical 3 mm of the roots were resected and apical class I cavity preparations were made. The roots were then randomly divided into three groups and retrofilled with one of the experimental materials. After 72 h of immersion in India ink, the roots were cleared and evaluated for leakage with a stereomicroscope. Statistical analysis indicated that the cermet ionomer cement with varnish group had significantly less leakage than the amalgam group (P cermet ionomer cement without varnish group (P 0.05).

  13. Robust synthesis of epoxy resin-filled microcapsules for application to self-healing materials.

    Science.gov (United States)

    Bolimowski, Patryk A; Bond, Ian P; Wass, Duncan F

    2016-02-28

    Mechanically and thermally robust microcapsules containing diglycidyl ether bisphenol A-based epoxy resin and a high-boiling-point organic solvent were synthesized in high yield using in situ polymerization of urea and formaldehyde in an oil-in-water emulsion. Microcapsules were characterized in terms of their size and size distribution, shell surface morphology and thermal resistance to the curing cycles of commercially used epoxy polymers. The size distribution of the capsules and characteristics such as shell thickness can be controlled by the specific parameters of microencapsulation, including concentrations of reagents, stirrer speed and sonication. Selected microcapsules, and separated core and shell materials, were analysed using thermogravimetric analysis and differential scanning calorimetry. It is demonstrated that capsules lose minimal 2.5 wt% at temperatures no higher than 120°C. These microcapsules can be applied to self-healing carbon fibre composite structural materials, with preliminary results showing promising performance. © 2016 The Author(s).

  14. Sound transmission through panels and shells filled with porous material in the presence of external flow

    OpenAIRE

    Zhou, Jie

    2014-01-01

    With increasingly tighter regulations on noise exposure during flight, aircraft designers have been compelled to innovate structures that minimise noise transmission into the cabin space. Porous material is widely used as a passive noise control medium because of their light weight, low cost, and broad band sound abatement effectiveness. The present work, inspired by the need to be able to predict noise transmission characteristics for commonly used constructions, incorporates the effect of f...

  15. Microleakage of conventional, resin-modified, and nano-ionomer glass ionomer cement as primary teeth filling material

    Directory of Open Access Journals (Sweden)

    Dita Madyarani

    2014-12-01

    Full Text Available Background: Glass ionomer cements are one of many dental materials that widely used in pediatric dentistry due to their advantage of fluoride release and chemical bond to tooth structure. Adherence of the filling material to the cavity walls is one of the most important characteristic that need to be examined its effect on microleakage. Purpose: This study was conducted to examine the microleakage of nano-ionomer glass ionomer cement compared with the conventional and resin-modified glass ionomer cements. Methods: Standard class V cavities sized 3 mm x 2 mm x 2 mm were made on a total of 21 extracted maxillary primary canine teeth and restored with the conventional, resin-modified, dan nano-ionomer glass ionomer cements. All the teeth were immersed in a 2% methylene blue dye for 4 hours. The depth of dye penetration was assessed using digital microscope after sectioning the teeth labio-palatally. The results were statistically analyzed using Kruskal-Wallis test. Results: All type of glass ionomer material showed microleakage. Conventional glass ionomer cement demonstrated the least microleakage with mean score 1.29. the resin-modified glass ionomer cements (mean score 1.57 and nano-ionomer glass ionomer cement (mean score 2.57. Conclusion: The conventional glassionomer, resin modified glassionomer, and nano-ionomer glassionomer showed micro leakage as filling material in primary teeth cavity. The micro leakage among three types was not significant difference. All three material were comparable in performance and can be used for filling material but still needs a coating material to fill the microleakage.Latar belakang: Semen ionomer kaca adalah salah satu dari banyak bahan gigi yang banyak digunakan dalam praktek kedokteran gigi anak karena bahan tersebut merilis fluoride dan berikatan kimia dengan struktur gigi. Perlekatan bahan tumpatan pada dinding kavitas adalah salah satu karakteristik paling penting yang perlu diteliti efeknya terhadap

  16. Chemical properties of gutta-percha endodontic filling material: investigation of five commercial brands; Propriedades quimicas de cones de guta-percha: avaliacao de diferentes marcas comerciais

    Energy Technology Data Exchange (ETDEWEB)

    Silva Junior, Joao Batista A.; Paula, Regina C.M.; Feitosa, Judith P.A. [Ceara Univ., Fortaleza, CE (Brazil). Dept. de Quimica Organica e Inorganica]. E-mail: juniorquim@yahoo.com.br; rpaula@dqoi.ufc.br; judith@dqoi.ufc.br; Gurgel Filho, Eduardo; Teixeira, Fabricio B [Universidade Estadual de Campinas, Piracicaba, SP (Brazil). Faculdade de Odontologia.Dept. de Odontologia Restauradora]. E-mail: gurgeleduardo@aol.com

    2001-07-01

    Chemical composition e thermal stability of five brands of gutta-percha endodontic filling material were investigated. Samples with higher amount of organic materials possess higher thermal stability. Investigation of gutta-percha polymer extracted from the endodontic filling by IR and NMR shows that the polymer is predominantly trans-polyisoprene. The thermal stability and molar mass were similar for four brands, however the 'Tanari' brand has got lower molar mass value than the other ones. (author)

  17. Establishment of characterizing parameters of clay as a filling material and coverage for repository

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Daisy M.M. dos; Tello, Cledola Cassia Oliveira de, E-mail: dmms@cdtn.br, E-mail: tellocc@cdtn.br [Centro de Desenvolvimento da Tecnologia Nucelar (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-07-01

    The multiple barriers of a repository should be able to provide adequate containment of radionuclides during all the previewed time for the operation and institutional control. One of these barriers is the backfill layer, located between the waste packages and other barriers. Furthermore, after shutting the disposal units with concrete, various materials are used to compose the final coverage of the deposition area. The backfill and the cover layer can be composed of clay or clay mixed with cement, with soil or with rocks. The last layer is a vegetation cover. The selection of the best clay should take into consideration some physical-chemical and mechanical properties. Bentonite is a clay with high absorption capacity, and large volume change in moistening and drying processes, being also effective in the contaminant retention. Additionally, it presents unique properties, such as high swelling potential. Some bentonite characterization works have been developed in the Laboratory of Cementation at CDTN/CNEN (LABCIM/CDTN). The sequence of experiments was: granulometric analysis, moisture, compaction test, hydraulic conductivity and cation exchange capacity. Some initial characterization results are presented and discussed. The paper summarizes these previous studies in order to have the basis for creating a protocol for characterization of a bentonite as a reference material. (author)

  18. Establishment of characterizing parameters of clay as a filling material and coverage for repository

    International Nuclear Information System (INIS)

    Santos, Daisy M.M. dos; Tello, Cledola Cassia Oliveira de

    2015-01-01

    The multiple barriers of a repository should be able to provide adequate containment of radionuclides during all the previewed time for the operation and institutional control. One of these barriers is the backfill layer, located between the waste packages and other barriers. Furthermore, after shutting the disposal units with concrete, various materials are used to compose the final coverage of the deposition area. The backfill and the cover layer can be composed of clay or clay mixed with cement, with soil or with rocks. The last layer is a vegetation cover. The selection of the best clay should take into consideration some physical-chemical and mechanical properties. Bentonite is a clay with high absorption capacity, and large volume change in moistening and drying processes, being also effective in the contaminant retention. Additionally, it presents unique properties, such as high swelling potential. Some bentonite characterization works have been developed in the Laboratory of Cementation at CDTN/CNEN (LABCIM/CDTN). The sequence of experiments was: granulometric analysis, moisture, compaction test, hydraulic conductivity and cation exchange capacity. Some initial characterization results are presented and discussed. The paper summarizes these previous studies in order to have the basis for creating a protocol for characterization of a bentonite as a reference material. (author)

  19. Cytotoxicity of newly developed pozzolan cement and other root-end filling materials on human periodontal ligament cell

    Directory of Open Access Journals (Sweden)

    Minju Song

    2014-02-01

    Full Text Available Objectives The purpose of this study was to evaluate in vitro cytotoxicity of the pozzolan cement and other root-end filling materials using human periodontal ligament cell. Materials and Methods Endocem (Maruchi, white ProRoot MTA (Dentsply, white Angelus MTA (Angelus, and Super EBA (Bosworth Co. were tested after set completely in an incubator at 37℃ for 7 days, Endocem was tested in two ways: 1 immediately after mixing (fresh specimens and 2 after setting completely like other experimental materials. The methods for assessment included light microscopic examination, cell counting and WST-1 assay on human periodontal ligament cell. Results In the results of microscopic examination and cell counting, Super EBA showed significantly lower viable cell than any other groups (p < 0.05. As the results of WST-1 assay, compared with untreated control group, there was no significant cell viability of the Endocem group. However, the fresh mixed Endocem group had significantly less cell viability. The cells exposed to ProRoot MTA and Angelus MTA showed the highest viability, whereas the cells exposed to Super EBA displayed the lowest viability (p < 0.05. Conclusions The cytotoxicity of the pozzolan cement (Endocem was comparable with ProRoot MTA and Angelus MTA. Considering the difficult manipulation and long setting time of ProRoot MTA and Angelus MTA, Endocem can be used as the alternative of retrofilling material.

  20. Modification induced by laser irradiation on physical features of plastics materials filled with nanoparticles

    Directory of Open Access Journals (Sweden)

    Scolaro Cristina

    2018-01-01

    Full Text Available The Thermal Laser Welding (TLW process involves localized heating at the interface of two pieces of plastic that will be joined. Polymeric materials of Ultra High Molecular Weight Polyethylene (UHMWPE, both pure and containing nanostructures at different concentrations (titanium and silver nanoparticles, were prepared as thin foils in order to produce an interface between a substrate transparent to the infrared laser wavelength and an highly absorbent substrate, in order to be welded by the laser irradiation. The used diode laser operates at 970 nm wavelength, in continuum, with a maximum energy of 100 mJ, for times of the order of 1 -60 s, with a spot of 300 μm of diameter. The properties of the polymers and of nanocomposite sheets, before and after the laser welding process, were measured in terms of optical characteristics, wetting ability, surface roughness and surface morphology.

  1. Preliminary laboratory assessments of a lightweight geocomposite material for embankment fill application

    Directory of Open Access Journals (Sweden)

    Felix Okonta

    2015-03-01

    Full Text Available The cost of retaining structures used for the lateral support of roadside embankments can be significantly reduced through the use of lightly cemented mixtures of expanded polystyrene (EPS beads and backfill soils as lightweight roadside embankment material. Four grades of residually derived sandy soils were mixed with EPS beads and the geocomposites were stabilised with 3% cement content, compacted and cured. The textural properties and shear strength parameters of dry and soaked specimens of the cemented geocomposites were determined by direct shear tests. The shear parameters and slope stability charts were used to simulate the slope of typical road embankments. The settlement potentials at different applied normal stresses were also determined. Inclusion of EPS reduced the dry density of the residual soils from an average value of 1790 kg/m3 to 1335 kg/m3. The maximum friction coefficient, tan ᴓ′, mobilised by the geocomposite specimens decreased with an increase in the soil fines content (>0.425 mm. The difference in tan ᴓ′ between the stabilised geocomposites and the natural soil was also dependent on the fines content. For an embankment height of 20 m, slope angles of 38° and 62° were determined for fine sand geocomposites in fully saturated drainage and drained conditions, respectively. Lower slope angles were determined for geocomposites made from silty, coarse and gravelly sands. A limiting embankment height of 50 m was determined for the four geocomposites. Rainfall-induced settlement of geocomposites was dependent on pre-inundation stiffness; for the range of applied stress up to 200 kPa, the settlement exhibited by the fine and silty sand geocomposites was lower than that for the coarse and gravelly sand geocomposites. Fine and silty sands make poor materials for slope embankments because of their poor hydraulic conductivity; however, fine and silty sand geocomposites have a good conductivity and friction angle to support

  2. The Effect of Hole Transport Material Pore Filling on Photovoltaic Performance in Solid-State Dye-Sensitized Solar Cells

    KAUST Repository

    Melas-Kyriazi, John

    2011-04-05

    A detailed investigation of the effect of hole transport material (HTM) pore filling on the photovoltaic performance of solid-state dye-sensitized solar cells (ss-DSCs) and the specific mechanisms involved is reported. It is demonstrated that the efficiency and photovoltaic characteristics of ss-DSCs improve with the pore filling fraction (PFF) of the HTM, 2,2\\',7,7\\'-tetrakis-(N, N-di-p-methoxyphenylamine)9,9\\'-spirobifluorene(spiro-OMeTAD). The mechanisms through which the improvement of photovoltaic characteristics takes place were studied with transient absorption spectroscopy and transient photovoltage/photocurrent measurements. It is shown that as the spiro-OMeTAD PFF is increased from 26% to 65%, there is a higher hole injection efficiency from dye cations to spiro-OMeTAD because more dye molecules are covered with spiro-OMeTAD, an order-of-magnitude slower recombination rate because holes can diffuse further away from the dye/HTM interface, and a 50% higher ambipolar diffusion coefficient due to an improved percolation network. Device simulations predict that if 100% PFF could be achieved for thicker devices, the efficiency of ss-DSCs using a conventional rutheniumdye would increase by 25% beyond its current value. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. The Effect of Hole Transport Material Pore Filling on Photovoltaic Performance in Solid-State Dye-Sensitized Solar Cells

    KAUST Repository

    Melas-Kyriazi, John; Ding, I-Kang; Marchioro, Arianna; Punzi, Angela; Hardin, Brian E.; Burkhard, George F.; Té treault, Nicolas; Grä tzel, Michael; Moser, Jacques-E.; McGehee, Michael D.

    2011-01-01

    A detailed investigation of the effect of hole transport material (HTM) pore filling on the photovoltaic performance of solid-state dye-sensitized solar cells (ss-DSCs) and the specific mechanisms involved is reported. It is demonstrated that the efficiency and photovoltaic characteristics of ss-DSCs improve with the pore filling fraction (PFF) of the HTM, 2,2',7,7'-tetrakis-(N, N-di-p-methoxyphenylamine)9,9'-spirobifluorene(spiro-OMeTAD). The mechanisms through which the improvement of photovoltaic characteristics takes place were studied with transient absorption spectroscopy and transient photovoltage/photocurrent measurements. It is shown that as the spiro-OMeTAD PFF is increased from 26% to 65%, there is a higher hole injection efficiency from dye cations to spiro-OMeTAD because more dye molecules are covered with spiro-OMeTAD, an order-of-magnitude slower recombination rate because holes can diffuse further away from the dye/HTM interface, and a 50% higher ambipolar diffusion coefficient due to an improved percolation network. Device simulations predict that if 100% PFF could be achieved for thicker devices, the efficiency of ss-DSCs using a conventional rutheniumdye would increase by 25% beyond its current value. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Study of filling material of dental composites. An analytical approach using radio-activation

    Energy Technology Data Exchange (ETDEWEB)

    Eke, Canel [Akdeniz Univ., Antalya (Turkey). Nuclear Sciences Application and Research Center; Akdeniz Univ., Antalya (Turkey). Div. of Physics Education; Er, Kursat [Akdeniz Univ., Antalya (Turkey). Dept. of Endodontics; Segebade, Christian [Akdeniz Univ., Antalya (Turkey). Nuclear Sciences Application and Research Center; Boztosun, Ismail [Akdeniz Univ., Antalya (Turkey). Nuclear Sciences Application and Research Center; Akdeniz Univ., Antalya (Turkey). Dept. of Physics

    2018-04-01

    The aim of this study is to carry out elemental analyses of dental composites acquired from different producers using photoactivation analysis (PAA). High energy electrons produced by an electron linear accelerator are absorbed by a tungsten disk (Bremsstrahlung converter) thereby producing high energy X-rays (bremsstrahlung). The dental composite materials under study were exposed to the bremsstrahlung radiation whereby radionuclides were produced through photonuclear reactions. Their radioactivities were measured using high resolution semiconductor spectrometers equipped with high purity germanium detectors (HPGe). The spectra were analysed using appropriate computer software. As a result, photonuclear reactions of 12 stable elements were detected in different dental composite species, and the elemental concentrations were calculated. For comparison, the dental composites were also investigated using scanning electron microscopy (SEM) and energy-dispersive X-ray fluorescence spectrometry (EDXRF). Various sizes and shapes of dental composites were observed using SEM. However, contents of dental composites, e.g. Mg, Ni, Ba and Sr were obtained by PAA whilst C, O, Al, S, Ba and Sr were detected by EDXRF spectrometry. The results for Ba and Sr obtained using the two techniques show considerable difference.

  5. Characteristics of low polymerization shrinkage flowable resin composites in newly-developed cavity base materials for bulk filling technique.

    Science.gov (United States)

    Nitta, Keiko; Nomoto, Rie; Tsubota, Yuji; Tsuchikawa, Masuji; Hayakawa, Tohru

    2017-11-29

    The purpose of this study was to evaluate polymerization shrinkage and other physical properties of newly-developed cavity base materials for bulk filling technique, with the brand name BULK BASE (BBS). Polymerization shrinkage was measured according to ISO/FDIS 17304. BBS showed the significantly lowest polymerization shrinkage and significantly higher depth of cure than conventional flowable resin composites (p<0.05). The Knoop hardness, flexural strength and elastic modulus of that were significantly lower than conventional flowable resin composites (p<0.05). BBS had the significantly greatest filler content (p<0.05). SEM images of the surface showed failure of fillers. The lowest polymerization shrinkage was due to the incorporation of a new type of low shrinkage monomer, which has urethane moieties. There were no clear correlations between inorganic filler contents and polymerization shrinkage, flexural strength and elastic modulus. In conclusion, the low polymerization shrinkage of BBS will be useful for cavity treatment in dental clinics.

  6. Evaluation of the physical properties of an endodontic Portland cement incorporating alternative radiopacifiers used as root-end filling material.

    Science.gov (United States)

    Camilleri, J

    2010-03-01

    To investigate the physical and chemical properties of Portland cement (PC) loaded with alternative radiopacifying materials for use as root-end filling materials in a mineral trioxide aggregate (MTA)-like system. Portland cement loaded with barium sulphate, gold and silver/tin alloy was mixed with water, and the physical and chemical properties of the hydrated cements were evaluated. MTA and intermediate restorative material (IRM) were used as controls. The radiopacity was compared to the equivalent thickness of aluminium, and the setting time of the cements was assessed using an indentation technique. The compressive strength and the stress-strain relationship were determined at 28 days. The stress-strain relationship was determined by monitoring the strain generated when the cement was subjected to compressive load. In addition, the pH was determined in water and simulated body fluid for a period of 28 days. The radiopacity of the cements using alternative radiopacifiers was comparable to MTA (P > 0.05). IRM demonstrated a higher radiopacity than all the materials tested (P cements with the exception of IRM exhibited an alkaline pH and had an extended setting time when compared to IRM. MTA had a longer setting time than the PC (P cement (P = 0.159). The addition of a radiopacifier retarded the setting time (P cements had comparable strength to PC (P > 0.05). IRM was the weakest cement tested (P cement loaded with gold radiopacifier had comparable strength to MTA (P = 1). The stress-strain relationship was linear for all the cements with IRM generating more strain on loading. Within the parameters set in this study, bismuth oxide in MTA can be replaced by gold or silver/tin alloy. The physical, mechanical and chemical properties of the cement replaced with alternative radiopacifiers were similar and comparable to ProRoot MTA.

  7. Coronal leakage of four intracanal medications after exposure to human saliva in the presence of a temporary filling material.

    Science.gov (United States)

    Verissimo, Rebeca Dibe; Gurgel-Filho, Eduardo Diogo; De-Deus, Gustavo; Coutinho-Filho, Tauby; de Souza-Filho, Francisco Jose

    2010-01-01

    To determine the time required for the recontamination of root canals medicated with four different materials. A total of 60 intact, caries-free, human single-rooted teeth with straight roots were selected for this study. After chemo-mechanical preparation they must be changed in the specimens into seven groups: 10 teeth medicated with calcium hydroxide (Ca(OH) 2) + Camphorated paramonochlorophanol (CPMC) (G.1); 10 medicated with 2.5% Sodium hypochlorite (NaOCL) (G.2); 10 medicated with 2% Chlorhexidine gluconate (CHX) in gel (G.3); 10 medicated with 2% CHX in gel + Ca(OH) 2 (G.4); 10 without intracanal medicament and sealed with a coronal temporary filling (G.5). Five teeth were without intracanal medicament and coronally unsealed, used as the positive control group (PC) (G.6) and 5 teeth with intact crowns used as the negative control group (NC) (G.7). Glass vials with rubber stoppers were adjusted for use. The medicaments were prepared and injected into the root canals using sterile plastic syringes. An apparatus was used to evaluate for 30 days leakage. The chamber was filled with 3 ml of human saliva and Brain Heart Infusion (BHI) broth, incubated at 37 degrees C and checked daily for the appearance of turbidity in the BHI broth. Recontamination was detected after an average time of 2.6 days in group 2, 15.9 days in group 3, 30 days in group 1, 27.6 days in group 4, 2.9 days in group 5, 1 day in the positive control, and there was no contamination in the negative control group. The NaOCl group showed the highest worst average of recontamination; on the other hand, high averages were also shown by Ca(OH) 2 + CPMC and Ca(OH) 2 + 2% CHX in gel.

  8. Efficacy of ultrasonic activation of NaOCl and orange oil in removing filling material from mesial canals of mandibular molars with and without isthmus

    Directory of Open Access Journals (Sweden)

    Mirela Sangoi BARRETO

    2015-01-01

    Full Text Available Objectives The aim of this study was to evaluate the volume of remaining filling material after passive ultrasonic irrigation (PUI of sodium hypochlorite (NaOCl and orange oil in mesial canals of mandibular molars, with and without isthmus. Material and Methods Thirty mesial roots of mandibular molars were divided according to the presence or absence of isthmus. Canals were prepared and filled (Micro-CT #1. Filling was removed using rotary instruments, and specimens were sub-divided into three groups according to the irrigation procedures: Conventional – conventional irrigation with NaOCl, PUI/NaOCl – PUI of NaOCl (three activations, 20 seconds each, and PUI/orange oil – PUI of orange oil (Micro-CT#2. Specimens were enlarged using the X2 and X3 ProTaper Next instruments and submitted to the same irrigation protocols (Micro-CT #3. Results No differences were found between the experimental groups in each stage of assessment (P>0.05. The volume of residual filling material was similar to that in Micro-CT #2 and Micro-CT #3, but lower than that observed in Micro-CT #1 (P<0.05. When groups were pooled according to the presence or absence of an isthmus, volume of residual filling material was higher in specimens presenting isthmus (P<0.05. Conclusions PUI of NaOCl or orange oil did not improve filling removal. Isthmus consists in an anatomical obstacle that impairs the removal of filling material.

  9. Heat release, time required, and cleaning ability of MTwo R and ProTaper universal retreatment systems in the removal of filling material.

    Science.gov (United States)

    Bramante, Clovis Monteiro; Fidelis, Natasha Siqueira; Assumpção, Tatiana Santos; Bernardineli, Norberti; Garcia, Roberto Brandão; Bramante, Alexandre Silva; de Moraes, Ivaldo Gomes

    2010-11-01

    This ex vivo study evaluated the heat release, time required, and cleaning efficacy of MTwo (VDW, Munich, Germany) and ProTaper Universal Retreatment systems (Dentsply/Maillefer, Ballaigues, Switzerland) and hand instrumentation in the removal of filling material. Sixty single-rooted human teeth with a single straight canal were obturated with gutta-percha and zinc oxide and eugenol-based cement and randomly allocated to 3 groups (n = 20). After 30-day storage at 37 °C and 100% humidity, the root fillings were removed using ProTaper UR, MTwo R, or hand files. Heat release, time required, and cleaning efficacy data were analyzed statistically (analysis of variance and the Tukey test, α = 0.05). None of the techniques removed the root fillings completely. Filling material removal with ProTaper UR was faster but caused more heat release. Mtwo R produced less heat release than the other techniques but was the least efficient in removing gutta-percha/sealer. ProTaper UR and MTwo R caused the greatest and lowest temperature increase on root surface, respectively; regardless of the type of instrument, more heat was released in the cervical third. Pro Taper UR needed less time to remove fillings than MTwo R. All techniques left filling debris in the root canals. Copyright © 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  10. Efficacy of Different Methods for Removing Root Canal Filling Material in Retreatment - An In-vitro Study.

    Science.gov (United States)

    Kasam, Swetha; Mariswamy, Annapoorna Ballagere

    2016-06-01

    Although success of endodontic therapy has significantly improved in the last few decades due to the introduction of novel materials and techniques, failures of endodontic therapy requiring re-treatment still comprise a significant percentage of patients requiring root canal treatment. To evaluate and compare the effective removal of gutta percha and sealer, amount of apical debris extrusion and time required for gutta percha removal using various endodontic files. Total 48 extracted mandibular premolars were mounted on acrylic blocks and endodontic procedure was carried out using size 40 K file and obturated using guttapercha and zinc oxide eugenol sealer. After one month storage, samples were decoronated, mounted on screw capped vials and subjected to removal of obturated material by four instruments: H files, safe sided H files, protaper universal retreatment rotary system and ultrasonic retreatment tip, grouped as 1, 2, 3, and 4 respectively. Only 2mm of obturated material from the coronal part was removed using no. 3 Gates Glidden drill, guttapercha was softened with a drop of xylene for 2 mins for each canal and retreatment was performed. The retreatment procedure was said to be complete when no visible debris were observed on the instrument flutes. The samples split into two halves and examined under stereomicroscope, photographed, assessed using AUTOCAD software and percentage of remaining filling material in coronal, middle, apical thirds of the canal was calculated in mm(2). Retreatment time was recorded in seconds and apically extruded debris was assessed by microbalance in grams for each tooth. The data was analyzed by using descriptive statistics, ANOVA and Scheffe's post hoc test through SPSS for windows (v 16.0). The ultrasonic retreatment tip had less percentage of residual guttapercha/sealer, shorter mean operating time and little apical extrusion with a significant difference (p<0.05) between the other groups. All techniques retained guttapercha

  11. Properties of n-eicosane-filled microcapsules with different morphology. Phase Change Materials studied by positron spectroscopy and complementary methods

    Energy Technology Data Exchange (ETDEWEB)

    Zgardzińska, B., E-mail: bozena.zgardzinska@poczta.umcs.lublin.pl [Department of Nuclear Methods, Institute of Physics, Maria Curie-Sklodowska University, Pl. M. Curie-Sklodowskiej 1, 20-031 Lublin (Poland); Filipek, M. [Department of Nuclear Methods, Institute of Physics, Maria Curie-Sklodowska University, Pl. M. Curie-Sklodowskiej 1, 20-031 Lublin (Poland); Fortuniak, W. [Center of Molecular and Macromolecular Studies, Polish Academy of Sciences, Sienkiewicza 112, 90-363 Łódź (Poland); Mroczek, P. [Department of Geoecology and Palaeogeography, Faculty of Earth Sciences and Spatial Management, Maria Curie-Sklodowska University, Al. Kraśnicka 2cd, 20-718 Lublin (Poland)

    2016-07-01

    The Positron Annihilation Lifetime Spectroscopy (PALS) was used to investigate properties of selected Phase Change Materials (PCMs) as a function of temperature from 123 K to 333 K. Three different PCM microcapsules investigated in this work were built of n-eicosane filling and a siloxane polymer as a shell material. It has been found that the properties of ortho-positronium (o-Ps) annihilating in n-eicosane filler depend on the microcapsule morphology. In the samples where the whole interior is composed of n-eicosane and the polymer forms the outer shell only, the n-eicosane behaves like a neat macroscopic sample. In the microcapsules containing the network of polymer threads inside the globule, n-eicosane shows no rise of o-Ps intensity with time which is typical for all pure alkanes. For this morphology, the melting point of n-eicosane is preceded by the 4 K wide temperature range, where the structure resembling the rotator phase is observed (rotator phase appears in neat even-numbered alkanes with carbon chain over 20 atoms). Supplementary data were obtained by the DSC method. SEM images confirmed the morphological differentiation of microcapsules. Low temperature (close to liquid nitrogen) destroys the structure of microcapsules, particularly their outer shell. - Highlights: • Polymer-alkane microcapsules were synthesized with different morphology. • Morphological diversity of microcapsules is reflected in the parameters of the PALS. • PALS show the effect of spatial limitations on the formation of lamellar structure. • PALS is a new way to determine the percentage of microcapsules components.

  12. Effectiveness of ProTaper Universal retreatment instruments used with rotary or reciprocating adaptive motion in the removal of root canal filling material.

    Science.gov (United States)

    Capar, I D; Arslan, H; Ertas, H; Gök, T; Saygılı, G

    2015-01-01

    To compare the effectiveness of ProTaper Universal retreatment instruments with continuous rotation and adaptive motion (AM; a modified reciprocating motion that combines rotational and reciprocating motion) in the removal of filling material. Mesiobuccal root canals in 36 mandibular first molars were instrumented up to size F2 with the ProTaper Universal instrument (Dentsply Maillefer, Ballaigues, Switzerland) and filled using sealer and ProTaper Universal F2 gutta-percha cones. Gutta-percha was then down-packed and the root canal backfilled using the extruder hand-piece of the Elements Obturation System (SybronEndo, Orange, CA, USA). The teeth were assigned to two groups (n = 18), and removal of the root fillings was performed using one of the following techniques: group 1) ProTaper Universal retreatment files used with rotational motion (RM) and group 2) ProTaper Universal retreatment files used with adaptive motion (AM) (600° clockwise/0° counter-clockwise to 370° clockwise/50° counter-clockwise). The teeth were sectioned, and both halves were analysed at 8 × magnification. The percentage of remaining filling material was recorded. The data were analysed statistically using the Student's t-test at a 95% confidence level (P ProTaper Universal retreatment files with adaptive motion removed more filling materials from root canals than the rotational movement. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  13. Diffusion and Leaching Behavior of Radionuclides in Category 3 Waste Encasement Concrete and Soil Fill Material – Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Mattigod, Shas V.; Wellman, Dawn M.; Bovaird, Chase C.; Parker, Kent E.; Clayton, Libby N.; Powers, Laura; Recknagle, Kurtis P.; Wood, Marcus I.

    2011-08-31

    One of the methods being considered for safely disposing of Category 3 low-level radioactive wastes is to encase the waste in concrete. Such concrete encasement would contain and isolate the waste packages from the hydrologic environment and would act as an intrusion barrier. The current plan for waste isolation consists of stacking low-level waste packages on a trench floor, surrounding the stacks with reinforced steel, and encasing these packages in concrete. These concrete-encased waste stacks are expected to vary in size with maximum dimensions of 6.4 m long, 2.7 m wide, and 4 m high. The waste stacks are expected to have a surrounding minimum thickness of 15 cm of concrete encasement. These concrete-encased waste packages are expected to withstand environmental exposure (solar radiation, temperature variations, and precipitation) until an interim soil cover or permanent closure cover is installed, and to remain largely intact thereafter. Any failure of concrete encasement may result in water intrusion and consequent mobilization of radionuclides from the waste packages. The mobilized radionuclides may escape from the encased concrete by mass flow and/or diffusion and move into the surrounding subsurface environment. Therefore, it is necessary to assess the performance of the concrete encasement structure and the ability of the surrounding soil to retard radionuclide migration. The retardation factors for radionuclides contained in the waste packages can be determined from measurements of diffusion coefficients for these contaminants through concrete and fill material. Some of the mobilization scenarios include (1) potential leaching of waste form before permanent closure cover is installed; (2) after the cover installation, long-term diffusion of radionuclides from concrete waste form into surrounding fill material; (3) diffusion of radionuclides from contaminated soils into adjoining concrete encasement and clean fill material. Additionally, the rate of

  14. Numerical Calculation of Light Metal Filling Material PELE%轻金属填充材料 PELE 的数值仿真研究

    Institute of Scientific and Technical Information of China (English)

    李干; 王志军; 李运禄; 魏波

    2016-01-01

    In order to analyze the influence of the light metal filling material on the Penetrator with Enhanced Lateral Efficiency (PELE),AUTODYN explicit nonlinear dynamic analysis software was used to simulate the penetration of PELE filled with different light metal materials against target plate,and the damage effects of different projectile on target plates were obtained.The simulation results shows that the lower hardness of filling material is,the short the length of residual jacket is.Mg-Li alloy is suitable for filling material of PELE.%为了研究铝镁等轻金属作为弹芯对横向效应增强型侵彻体(PELE)的影响,采用显式非线性动力分析软件 AU-TODYN 对内装不同轻金属材料弹丸进行侵彻靶板数值模拟,获得了不同弹体对靶板的毁伤效应。结果表明:填充材料硬度越低,PELE 壳体残留越少,锂镁合金适宜作为 PELE 的填充材料。

  15. 33 CFR 338.2 - Activities involving the discharge of dredged or fill material into waters of the U.S.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Activities involving the discharge of dredged or fill material into waters of the U.S. 338.2 Section 338.2 Navigation and Navigable Waters CORPS OF ENGINEERS, DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE OTHER CORPS ACTIVITIES INVOLVING...

  16. The impacts of dental filling materials on RapidArc treatment planning and dose delivery: Challenges and solution

    Energy Technology Data Exchange (ETDEWEB)

    Mail, Noor; Al-Ghamdi, S.; Saoudi, A. [Princess Norah Oncology Center, National Guard Health Affairs, Jeddah 21423, Saudi Arabia and King Abdullah International Medical Research Center, Jeddah 21423 (Saudi Arabia); Albarakati, Y.; Ahmad Khan, M.; Saeedi, F.; Safadi, N. [Princess Norah Oncology Center, National Guard Health Affairs, Jeddah 21423 (Saudi Arabia)

    2013-08-15

    Purpose: The presence of high-density material in the oral cavity creates dose perturbation in both downstream and upstream directions at the surfaces of dental filling materials (DFM). In this study, the authors have investigated the effect of DFM on head and neck RapidArc treatment plans and delivery. Solutions are proposed to address (1) the issue of downstream dose perturbation, which might cause target under dosage, and (2) to reduce the upstream dose from DFM which may be the primary source of mucositis. In addition, an investigation of the clinical role of a custom-made plastic dental mold/gutter (PDM) in sparing the oral mucosa and tongue reaction is outlined.Methods: The influence of the dental filling artifacts on dose distribution was investigated using a geometrically well-defined head and neck intensity modulated radiation therapy (IMRT) verification phantom (PTW, Freiberg, Germany) with DFM inserts called amalgam, which contained 50% mercury, 25% silver, 14% tin, 8% copper, and 3% other trace metals. Three RapidArc plans were generated in the Varian Eclipse System to treat the oral cavity using the same computer tomography (CT) dataset, including (1) a raw CT image, (2) a streaking artifacts region, which was replaced with a mask of 10 HU, and (3) a 2 cm-thick 6000 HU virtual filter [a volume created in treatment planning system to compensate for beam attenuation, where the thickness of this virtual filter is based on the measured percent depth dose (PDD) data and Eclipse calculation]. The dose delivery for the three plans was verified using Gafchromic-EBT2 film measurements. The custom-made PDM technique to reduce backscatter dose was clinically tested on four head and neck cancer patients (T3, N1, M0) with DFM, two patients with PDM and the other two patients without PDM. The thickness calculation of the PDM toward the mucosa and tongue was purely based on the measured upstream dose. Patients’ with oral mucosal reaction was clinically examined

  17. The impacts of dental filling materials on RapidArc treatment planning and dose delivery: Challenges and solution

    International Nuclear Information System (INIS)

    Mail, Noor; Al-Ghamdi, S.; Saoudi, A.; Albarakati, Y.; Ahmad Khan, M.; Saeedi, F.; Safadi, N.

    2013-01-01

    Purpose: The presence of high-density material in the oral cavity creates dose perturbation in both downstream and upstream directions at the surfaces of dental filling materials (DFM). In this study, the authors have investigated the effect of DFM on head and neck RapidArc treatment plans and delivery. Solutions are proposed to address (1) the issue of downstream dose perturbation, which might cause target under dosage, and (2) to reduce the upstream dose from DFM which may be the primary source of mucositis. In addition, an investigation of the clinical role of a custom-made plastic dental mold/gutter (PDM) in sparing the oral mucosa and tongue reaction is outlined.Methods: The influence of the dental filling artifacts on dose distribution was investigated using a geometrically well-defined head and neck intensity modulated radiation therapy (IMRT) verification phantom (PTW, Freiberg, Germany) with DFM inserts called amalgam, which contained 50% mercury, 25% silver, 14% tin, 8% copper, and 3% other trace metals. Three RapidArc plans were generated in the Varian Eclipse System to treat the oral cavity using the same computer tomography (CT) dataset, including (1) a raw CT image, (2) a streaking artifacts region, which was replaced with a mask of 10 HU, and (3) a 2 cm-thick 6000 HU virtual filter [a volume created in treatment planning system to compensate for beam attenuation, where the thickness of this virtual filter is based on the measured percent depth dose (PDD) data and Eclipse calculation]. The dose delivery for the three plans was verified using Gafchromic-EBT2 film measurements. The custom-made PDM technique to reduce backscatter dose was clinically tested on four head and neck cancer patients (T3, N1, M0) with DFM, two patients with PDM and the other two patients without PDM. The thickness calculation of the PDM toward the mucosa and tongue was purely based on the measured upstream dose. Patients’ with oral mucosal reaction was clinically examined

  18. Apical adaptation, sealing ability and push-out bond strength of five root-end filling materials

    Directory of Open Access Journals (Sweden)

    Pablo Andrés AMOROSO-SILVA

    2014-08-01

    Full Text Available This study compared the fluid filtration, adaptation to the root canal walls, and the push-out bond strength of two resin-based sealers and three calcium silicate-based retrograde filling materials. Fifty maxillary canines were shaped using manual instruments and the apical portion was sectioned. Retrograde cavities of 3-mm depth were prepared. The specimens were divided into five groups (n = 10: Sealer 26 (S26; MBPc (experimental; MTA; Portland cement with 20% zirconium oxide (PC/ZO, and Portland cement with 20% calcium tungstate (PC/CT. The fluid filtration was measured at 7 and 15 days. To evaluate the interfacial adaptation, sections of the teeth, 1 and 2 mm from the apex, were prepared and the percentage of gaps was calculated. The push-out bond strength at 2 mm from the apex was evaluated. Statistical analysis was performed using the ANOVA/Tukey’s test (p < 0.05. At 7 and 15 days (p = 0.0048, p = 0.006, the PC/CT group showed higher fluid filtration values when compared to other groups. At 1 mm from the apex, no statistical differences in the adaptation were found among the cements (p = 0.44. At 2 mm from the apex, the PC/ZO group presented statistically lower percentage of gaps than S26, MBPc, and MTA (p = 0.0007. The MBPc group showed higher push-out bond strength than other cements evaluated (p = 0.0008. The fluid filtration and interfacial adaptation of the calcium silicate-based cements were similar to those of the resin-based cements. The resinous cement MBPc showed superior push-out bond strength.

  19. High-etch-rate bottom-antireflective coating and gap-fill materials using dextrin derivatives in via first dual-Damascene lithography process

    Science.gov (United States)

    Takei, Satoshi; Sakaida, Yasushi; Shinjo, Tetsuya; Hashimoto, Keisuke; Nakajima, Yasuyuki

    2008-03-01

    The present paper describes a novel class of bottom antireflective coating (BARC) and gap fill materials using dextrin derivatives. The general trend of interconnect fabrication for such a high performance LSI is to apply cupper (Cu)/ low-dielectric-constant (low-k) interconnect to reduce RC delay. A via-first dual damascene process is one of the most promising processes to fabricate Cu/ low-k interconnect due to its wide miss-alignment margin. The sacrificial materials containing dextrin derivatives under resist for lithography were developed in via-first dual damascene process. The dextrin derivatives in this study was obtained by the esterification of the hydroxyl groups of dextrin resulting in improved solubility in the resist solvents such as propylene glycol monomethylether, propylene glycol monomethylether acetate, and ethyl lactate due to avoid the issue of defects that were caused by incompatability. The etch rate of our developed BARC and gap fill materials using dextrin derivatives was more than two times faster than one of the ArF resists evaluated in a CF4 gas condition using reactive ion etching. The improved etch performance was also verified by comparison with poly(hydroxystyrene), acrylate-type materials and latest low-k materials as a reference. In addition to superior etch performance, these materials showed good resist profiles and via filling performance without voids in via holes.

  20. Evaluation of bacterial leakage of four root- end filling materials: Gray Pro Root MTA, White Pro Root MTA, Root MTA and Portland Cement (type I

    Directory of Open Access Journals (Sweden)

    Zarabian M.

    2005-07-01

    Full Text Available Background and Aim: Today several materials have been used for root- end filling in endodontic surgery. Optimal properties of Pro Root MTA in in-vitro and in-vivo studies has been proven. On the other hand, based on some studies, Root MTA (Iranian Pro Root MTA and Portland cement are similar to Pro Root MTA in physical and biologic properties. The aim of this study was to evaluate bacterial leakage (amount and mean leakage time of four root- end filling materials. Materials and Methods: In this experimental in-vitro study, seventy six extracted single- rooted human teeth were randomly divided into six groups for root-end filling with gray Pro Root MTA, white Pro Root MTA, Root MTA (Iranian Pro Root MTA, Portland Cement (type I and positive and negative control groups. Root canals were instrumented using the step- back technique. Root- end filling materials were placed in 3mm ultra sonic retro preparations. Samples and microleakage model system were sterilized in autoclave. The apical 3-4 mm of the roots were immersed in phenol red with 3% lactose broth culture medium. The coronal access of each specimen was inoculated every 24h with a suspension of Streptococcus sanguis (ATCC 10556. Culture media were observed every 24h for colour change indicating bacterial contamination for 60 days. Statistical analysis was performed using log- rank test with P<0.05 as the limit of significance. Results: At the end of study 50%, 56.25%, 56.25% and 50% of specimens filled with Gray Pro Root MTA, White Pro Root MTA. Root MTA and Portland Cement (type I had evidence of leakage respectively. The mean leakage time was 37.19±6.29, 36.44±5.81, 37.69±5.97 and 34.81±6.67 days respectively. Statistical analysis of data showed no significant difference among the leakage (amount and mean leakage time of the four tested root- end filling materials (P=0.9958. Conclusion: Based on the results of this study, there were no significant differences in leakage among the four

  1. Cuspal deflection and microleakage in premolar teeth restored with bulk-fill flowable resin-based composite base materials.

    Science.gov (United States)

    Moorthy, A; Hogg, C H; Dowling, A H; Grufferty, B F; Benetti, A R; Fleming, G J P

    2012-06-01

    To assess the cuspal deflection and cervical microleakage of standardised Class II cavities incrementally filled with a dimethacrylate RBC or bulk-fill flowable RBC bases. Twenty-four sound upper premolar teeth with Class II cavities were allocated to three groups (n=8). Restoration of the teeth involved the placement of an RBC (GrandioSO) in eight oblique increments (Group A) or Groups B and C were restored to within 2 mm of the palatal cusp in a single increment with bulk-fill flowable RBC bases (SDR and x-tra base) before the two occlusal cavity increments were placed with GrandioSO. Buccal and palatal cusp deflections were recorded postirradiation using a twin channel deflection measuring gauge. Following restoration, the teeth were thermocycled, immersed in 0.2% basic fuchsin dye for 24h, sectioned and examined for cervical microleakage. The mean total cuspal deflection for the oblique incremental restoration technique was 11.26 (2.56) μm (Group A) and 4.63 (1.19) μm (Group B) and 4.73 (0.99) μm (Group C) for the bulk-fill flowable RBC bases. A significant increase in the mean total cuspal deflection for the incrementally filled GrandioSO compared with the SDR (P=0.007) and x-tra base (P=0.005) restored teeth was evident. No significant difference in the cervical microleakage scores was recorded between groups AC (P>0.05). The bulk-fill flowable RBC bases significantly reduced cuspal deflection compared with a conventional RBC restored in an oblique incremental filling technique with no associated change in cervical microleakage recorded. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Filled skutterudite antimonides: Validation of the electron-crystal phonon-glass approach to new thermoelectric materials

    Energy Technology Data Exchange (ETDEWEB)

    Mandrus, D; Sales, B C; Keppens, V [and others

    1997-07-01

    After a brief review of the transport and thermoelectric properties of filled skutterudite antimonides, the authors present resonant ultrasound, specific heat, and inelastic neutron scattering results that establish the existence of two low-energy vibrational modes in the filled skutterudite LaFe{sub 3}CoSb{sub 12}. It is likely that at least one of these modes represents the localized, incoherent vibrations of the La ion in an oversized atomic cage. These results support the usefulness of weakly bound, rattling ions for the improvement of thermoelectric performance.

  3. Effects of filling material and laser power on the formation of intermetallic compounds during laser-assisted friction stir butt welding of steel and aluminum alloys

    Science.gov (United States)

    Fei, Xinjiang; Jin, Xiangzhong; Peng, Nanxiang; Ye, Ying; Wu, Sigen; Dai, Houfu

    2016-11-01

    In this paper, two kinds of materials, Ni and Zn, are selected as filling material during laser-assisted friction stir butt welding of Q235 steel and 6061-T6 aluminum alloy, and their influences on the formation of intermetallic compounds on the steel/aluminum interface of the joints were first studied. SEM was used to analyze the profile of the intermetallic compound layer and the fractography of tensile fracture surfaces. In addition, EDS was applied to investigate the types of the intermetallic compounds. The results indicate that a thin iron-abundant intermetallic compound layer forms and ductile fracture mode occurs when Ni is added, but a thick aluminum-abundant intermetallic compound layer generates and brittle fracture mode occurs when Zn is added. So the tensile strength of the welds with Ni as filling material is greater than that with Zn as filling material. Besides, the effect of laser power on the formation of intermetallic compound layer when Ni is added was investigated. The preheated temperature field produced by laser beam in the cross section of workpiece was calculated, and the tensile strength of the joints at different laser powers was tested. Results show that only when suitable laser power is adopted, can suitable preheating temperature of the steel reach, then can thin intermetallic compound layer form and high tensile strength of the joints reach. Either excessive or insufficient laser power will reduce the tensile strength of the joints.

  4. Contamination of tooth-colored mineral trioxide aggregate used as a root-end filling material: a bacterial leakage study.

    Science.gov (United States)

    Montellano, Angela M; Schwartz, Scott A; Beeson, Thomas J

    2006-05-01

    This experiment investigated the ability of tooth-colored mineral trioxide aggregate (MTA) to maintain an apical seal in the presence of bacteria when contaminated with blood, saline or saliva. Ninety extracted human teeth with single canals were randomly placed into six groups of 15. Canals were prepared to size 50. The apical 3 mm of each root was removed and 3 mm root-end preparations were made with a #329 bur. Root-end preparations in groups 1 through 3 were filled with MTA after contamination with blood, saline, or saliva, respectively. In group 4, uncontaminated root-end preparations were filled with MTA. Groups 5 and 6 served as negative and positive controls. A tube/tooth assembly was utilized to suspend each root end in Trypticase Soy Broth (TSB). The access chambers were filled with Staphylococcus epidermidis. Positive growth over thirty days was demonstrated by turbidity of the TSB. Vitek analysis was used to confirm the presence of S. epidermidis in the positive samples. Data evaluation consisted of a chi(2) analysis (p < 0.05). Although all experimental groups demonstrated leakage, tooth-colored MTA contaminated with saliva (group 3) leaked significantly more than the uncontaminated tooth-colored MTA (group 4) (p = 0.028).

  5. 装填材料对PELE侵彻混凝土效能影响研究%Influence of filling material on penetration of PELE into concrete target

    Institute of Scientific and Technical Information of China (English)

    范少博; 陈智刚; 郭光全; 侯秀成; 陈冬梅

    2012-01-01

    为研究惰性装填物对PELE侵彻混凝土靶板效能影响,利用有限元软件LS-DYNA对不同惰性装填物的PELE侵彻混凝土靶板进行数值模拟.结果表明:与PELE侵彻混凝土靶板相比钢靶的形成破片质量较大、速度较慢;不同装填物对靶板的破坏效能不同;尼龙装填物比橡胶对靶板破坏的面积大,破片数量多.通过实验验证了模拟结果的正确性和可靠性.%Researches on the influence of inert fillings on penetration of PELE into concrete targets were carried out Penetration of PELE with different inert fillings into concrete targets was simulated by LS-DYNA. The results show that the fragments formed by penetration into concrete targets are larger and the velocity is lower than those into steel targets, and the different fillings have different damage efficiency. The damage area and the amount of fragments are larger for nylon filling material than for rubber. Correctness and reliability of the simulation results are verified by experiments.

  6. The influence of irradiation potential on the degree of conversion and mechanical properties of two bulk-fill flowable RBC base materials.

    Science.gov (United States)

    Finan, Leah; Palin, William M; Moskwa, Natalia; McGinley, Emma Louise; Fleming, Garry J P

    2013-08-01

    To assess the depth of cure claims of two bulk-fill flowable RBC bases (SDR and x-tra base) using Fourier transform infrared (FTIR) spectroscopy, biaxial flexure strength (BFS), and Vickers hardness number (VHN) for specimen depths of 8mm (in 1mm increments). The degree of conversion (DC) was measured by monitoring the peak height (6164cm(-1)) of specimens (11.0±0.1mm diameter, 1.0±0.1mm thickness) during light irradiation for 20s using a quartz tungsten halogen light curing unit at 650±26mW/cm(2). DC was measured up to 120s post irradiation and repeated (n=3) for irradiation depths up to 8mm (in 1mm increments). Further series (n=20) of eight discs were prepared, stacked, light irradiated and numbered from one to eight (distance from the LCU). The specimens were stored at 37±1°C for 24h and BFS tested with the fracture fragments used to determine the VHN for each specimen. X-tra base can be irradiated to 8mm without a change in DC, something the SDR material cannot claim. However, the DC results confirm both bulk-fill flowable RBC bases have a depth of cure in excess of 4mm. One-way ANOVAs of BFS and VHN data showed significant differences between irradiation depths for x-tra base and SDR with increasing irradiation depth (4mm) resulting in significant reductions in mean BFS and VHN. The claims that the bulk-fill flowable RBC bases have a depth of cure in excess of 4mm can be confirmed but the differing chemistry of the resin formulations and filler characteristics contribute to significant differences in DC, BFS and VHN data between the two materials tested. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  7. Study of the pore filling fraction of carbazole-based hole-transporting materials in solid-state dye-sensitized solar cells

    Directory of Open Access Journals (Sweden)

    Marwa Ben Manaa

    2016-07-01

    Full Text Available Carbazole-based molecular glasses have emerged as a promising alternative to the widely used hole-transporting materials (HTM spiro-OMeTAD in solid-state dye-sensitized solar cells (DSSCs. The pore filling fraction (PFF of the mesoporous TiO2 layer by the HTM appears as a key parameter determining the final efficiency of a DSSC. In this work, the pore-filling properties of a family of carbazole-based HTMs are investigated for the first time and the photovoltaic behavior of DSSC devices (fabricated using the D102 dye is discussed in light of the present findings. It is found that N-aryl substituted 3,6-bis(diphenylaminyl-carbazole derivatives exhibit relatively low PFF of ca. 60%. Methoxy groups on the diphenylamine moieties have little influence on the PFF, indicating that the strong enhancement in power conversion efficiency (PCE is not related to an improved filling of the pores by the HTM. N-alkylated HTMs lead to higher PFF, increasing with the alkyl chain length, up to 78%.

  8. Effectiveness of ProTaper, D-RaCe, and Mtwo retreatment files with and without supplementary instruments in the removal of root canal filling material.

    Science.gov (United States)

    Marques da Silva, B; Baratto-Filho, F; Leonardi, D P; Henrique Borges, A; Volpato, L; Branco Barletta, F

    2012-10-01

    To assess the efficacy of different retreatment rotary files in removing gutta-percha and endodontic sealer from canals. Ninety straight single-rooted premolars were prepared up to a size 30 and filled with gutta-percha and sealer and then randomly assigned to six retreatment groups (n = 15). Groups I, III, and V were retreated using rotary systems ProTaper Universal Retreatment (PTUR), D-RaCe, and Mtwo Retreatment, respectively. Groups II, IV, and VI were retreated using the additional instruments F4, size 40, .04 taper RaCe, and size 40, .04 taper Mtwo, respectively. The roots were split vertically, and images of the halves were obtained using a high-resolution scanner and evaluated with AutoCAD software to calculate the percentage of residual material. Data were analyzed with Kruskal-Wallis and Student-Newman-Keuls tests using a 5% significance cutoff (P 0.05) between groups when additional instruments were used. The percentage of residual material was lowest in the PTUR group and was statistically significant only when compared to the D-RaCe system (P = 0.0038). All root canals had residual filling material after retreatment even when additional instruments were used. © 2012 International Endodontic Journal.

  9. Periapical tissue response after use of intermediate restorative material, gutta-percha, reinforced zinc oxide cement, and mineral trioxide aggregate as retrograde root-end filling materials: a histologic study in dogs.

    Science.gov (United States)

    Wälivaara, Dan-Åke; Abrahamsson, Peter; Isaksson, Sten; Salata, Luiz Antonio; Sennerby, Lars; Dahlin, Christer

    2012-09-01

    To investigate the periapical tissue response of 4 different retrograde root-filling materials, ie, intermediate restorative material, thermoplasticized gutta-percha, reinforced zinc oxide cement (Super-EBA), and mineral trioxide aggregate (MTA), in conjunction with an ultrasonic root-end preparation technique in an animal model. Vital roots of the third and fourth right mandibular premolars in 6 healthy mongrel dogs were apicectomized and sealed with 1 of the materials using a standardized surgical procedure. After 120 days, the animals were sacrificed and the specimens were analyzed radiologically, histologically, and scanning electron microscopically. The Fisher exact test was performed on the 2 outcome values. Twenty-three sections were analyzed histologically. Evaluation showed better re-establishment of the periapical tissues and generally lower inflammatory infiltration in the sections from teeth treated with the intermediate restorative material and the MTA. New root cement on the resected dentin surfaces was seen on all sections regardless of the used material. New hard tissue formation, directly on the surface of the material, was seen only in the MTA sections. There was no statistical difference in outcome among the tested materials. The results from this dog model favor the intermediate restorative material and MTA as retrograde fillings when evaluating the bone defect regeneration. MTA has the most favorable periapical tissue response when comparing the biocompatibility of the materials tested. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Wear studies on ZrO2-filled PEEK as coating bearing materials for artificial cervical discs of Ti6Al4V

    International Nuclear Information System (INIS)

    Song, Jian; Liu, Yuhong; Liao, Zhenhua; Wang, Song; Tyagi, Rajnesh; Liu, Weiqiang

    2016-01-01

    Polyetheretherketone (PEEK) and its composite coatings are believed to be the potential candidates' bio-implant materials. However, these coatings have not yet been used on the surface of titanium-based orthopedics and joint products and very few investigations on the tribological characteristics could be found in the published literature till date. In this study, the wettabilities, composition and micro-hardness were characterized using contact angle measurement, scanning electron microscopy (SEM) and hardness tester. The tribological tests were conducted using a ball-on-disc contact pair under 25% newborn calf serum (NCS) lubricated condition. For comparison, bare Ti6Al4V was studied. The obtained results revealed that those PEEK/ZrO 2 composite coatings could improve the tribological properties of Ti6Al4V significantly. Adhesive wear and mild abrasive wear might be the dominant wear and failure mechanisms for PEEK/ZrO 2 composite coatings in NCS lubricated condition. After comprehensive evaluation in the present study, 5 wt.% ZrO 2 nanoparticles filled PEEK coating displayed the optimum tribological characteristics and could be taken as a potential candidate for the bearing material of artificial cervical disc. - Graphical abstract: Polyetheretherketone (PEEK) is a type of biomaterial which might be used in surface modification. In this study, the wettabilities, composition, hardness, friction and wear characteristics of PEEK/ZrO 2 coatings were investigated, compared with bare Ti6Al4V sample. After comprehensive evaluation, 5 wt.% ZrO 2 nanoparticles filled PEEK coating displayed the optimum tribological characteristics and could be taken as a potential candidate for the bearing material of artificial cervical disc. - Highlights: • PEEK coating were filled by ZrO 2 nanoparticles with different weight percentage. • The lubrication regime of all the tested samples are boundary lubrication. • Adhesive wear and mild abrasive wear were the dominant wear

  11. Wear studies on ZrO{sub 2}-filled PEEK as coating bearing materials for artificial cervical discs of Ti6Al4V

    Energy Technology Data Exchange (ETDEWEB)

    Song, Jian [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Liu, Yuhong, E-mail: liuyuhong@tsinghua.edu.cn [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Liao, Zhenhua; Wang, Song [Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China); Tyagi, Rajnesh [Department of Mechanical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi 221005 (India); Liu, Weiqiang, E-mail: weiqliu@hotmail.com [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China)

    2016-12-01

    Polyetheretherketone (PEEK) and its composite coatings are believed to be the potential candidates' bio-implant materials. However, these coatings have not yet been used on the surface of titanium-based orthopedics and joint products and very few investigations on the tribological characteristics could be found in the published literature till date. In this study, the wettabilities, composition and micro-hardness were characterized using contact angle measurement, scanning electron microscopy (SEM) and hardness tester. The tribological tests were conducted using a ball-on-disc contact pair under 25% newborn calf serum (NCS) lubricated condition. For comparison, bare Ti6Al4V was studied. The obtained results revealed that those PEEK/ZrO{sub 2} composite coatings could improve the tribological properties of Ti6Al4V significantly. Adhesive wear and mild abrasive wear might be the dominant wear and failure mechanisms for PEEK/ZrO{sub 2} composite coatings in NCS lubricated condition. After comprehensive evaluation in the present study, 5 wt.% ZrO{sub 2} nanoparticles filled PEEK coating displayed the optimum tribological characteristics and could be taken as a potential candidate for the bearing material of artificial cervical disc. - Graphical abstract: Polyetheretherketone (PEEK) is a type of biomaterial which might be used in surface modification. In this study, the wettabilities, composition, hardness, friction and wear characteristics of PEEK/ZrO{sub 2} coatings were investigated, compared with bare Ti6Al4V sample. After comprehensive evaluation, 5 wt.% ZrO{sub 2} nanoparticles filled PEEK coating displayed the optimum tribological characteristics and could be taken as a potential candidate for the bearing material of artificial cervical disc. - Highlights: • PEEK coating were filled by ZrO{sub 2} nanoparticles with different weight percentage. • The lubrication regime of all the tested samples are boundary lubrication. • Adhesive wear and mild abrasive

  12. Long-Term Strength of a Thick-Walled Pipe Filled with an Aggressive Medium, with Account for Damageability of the Pipe Material and Residual Strength

    Science.gov (United States)

    Piriev, S. A.

    2018-01-01

    This paper describes the study of scattered fracture of a thick-walled pipe filled with an aggressive medium, which creates uniform pressure on the inner surface of the pipe. It is assumed that the aggressive medium affects only the value of instantaneous strength. Damageability is described by an integral operator of the hereditary type. The problem is solved with allowance for residual strength of the pipe material behind the fracture front. Numerical calculation is carried out, and relationships between the fracture front coordinate and time for various concentrations of the aggressive medium and residual strength behind the fracture front are constructed.

  13. Bulk-Fill Resin Composites

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Havndrup-Pedersen, Cæcilie; Honoré, Daniel

    2015-01-01

    the restorative procedure. The aim of this study, therefore, was to compare the depth of cure, polymerization contraction, and gap formation in bulk-fill resin composites with those of a conventional resin composite. To achieve this, the depth of cure was assessed in accordance with the International Organization...... for Standardization 4049 standard, and the polymerization contraction was determined using the bonded-disc method. The gap formation was measured at the dentin margin of Class II cavities. Five bulk-fill resin composites were investigated: two high-viscosity (Tetric EvoCeram Bulk Fill, SonicFill) and three low......-viscosity (x-tra base, Venus Bulk Fill, SDR) materials. Compared with the conventional resin composite, the high-viscosity bulk-fill materials exhibited only a small increase (but significant for Tetric EvoCeram Bulk Fill) in depth of cure and polymerization contraction, whereas the low-viscosity bulk...

  14. Possibilities of structure stabilisation in saliniferous formations using salt grit as a filling material; Moeglichkeiten der Gefuegestabilisierung von Salzgrusversatz

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Sebastian; Gruner, Matthias; Mischo, Helmut [TU Bergakademie Freiberg (Germany). Inst. fuer Bergbau und Spezialtiefbau

    2014-09-15

    The final disposal of high-active wastes in deep geological formations is an issue of great national and international import. On account of its good thermal conductivity and creep capability much research is currently focussed on sand as a host rock material. After the emplacement of wastes in abandoned mining cavities these must be sealed up to prevent fluids from coming into contact with the wastes. This must be done using materials that are either native or similar to the materials of the host formation. A particularly suitable material in the case of saliniferous formations is salt grit. Up to this point investigations have primarily been focused on preparing a suitable salt grit material and the rheological properties of the binding agent. This article presents and interprets the results of preliminary experiments on the miscibility of salt grit and binding agent suspensions. The MgO and CaSO{sub 4}-based binding agent systems analysed proved to be suitable. Among the MgO binding agents a composition of 3:1:8 was found to be more suitable than one of 5:1:8 on account of its lower initial viscosity. This reduces the amount of mixing required for wetting the material across all grain sizes, improving the chances of success. In the case of the two semihydrates of CaSO{sub 4} both the α and the β semihydrate proved suitable. This is due to a low fluid content which still also allows for a sufficiently low viscosity of the binding agent suspensions.

  15. The outcome of apical microsurgery using MTA as the root-end filling material: 2- to 6-year follow-up study.

    Science.gov (United States)

    Çalışkan, M K; Tekin, U; Kaval, M E; Solmaz, M C

    2016-03-01

    To evaluate the influence of various predictors on the healing outcome 2-6 years after apical microsurgery (AMS) using MTA as the root-end filling material. A total of 90 anterior teeth with asymptomatic persistent periradicular periodontitis of strictly endodontic origin that failed after either nonsurgical or surgical treatment were included. Surgery was completed under local anaesthesia using a standardized clinical protocol. Clinical and radiographic measures as well as the follow-up period were used to determine the healing outcome. For statistical analysis of the predictors, the outcome was dichotomized into healed cases and nonhealed cases. Odds ratios were calculated, and Pearson chi-square or Fisher's exact tests were used to analyse the data. Clinical and radiographic assessment of AMS revealed that 80% were healed, 14.4% were nonhealed, whilst 5.6% were judged to be uncertain. None of the various predictors investigated had a significant influence on the outcome of AMS. The results of this clinical study demonstrated that 80% of cases that received apical microsurgery healed when using MTA as the root-end filling material. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  16. Optical, magnetic, and dielectric properties of opal matrices with intersphere nanocavities filled with crystalline multiferroic, piezoelectric, and segnetoelectric materials

    Czech Academy of Sciences Publication Activity Database

    Samoilovich, M.I.; Rinkevich, A.B.; Bovtun, Viktor; Belyanin, A.F.; Kempa, Martin; Nuzhnyy, Dmitry; Tsvetkov, M.Yu.; Klescheva, S.M.

    2013-01-01

    Roč. 83, č. 11 (2013), s. 2132-2147 ISSN 1070-3632 R&D Projects: GA ČR GAP204/12/0232 Institutional support: RVO:68378271 Keywords : composites * opal matrices * optical, magnetic, and dielectric properties Subject RIV: JI - Composite Materials Impact factor: 0.418, year: 2013

  17. A multi-scale methodology to model damage, deformation and ignition of highly-filled energetic materials

    Energy Technology Data Exchange (ETDEWEB)

    Vivier, G. [Paris Univ., Paris (France). LMT Cachan; CEA Le Ripault, Monts (France); Trumel, H. [CEA Le Ripault, Monts (France); Hild, F. [Paris Univ., Paris (France). LMT Cachan

    2009-07-01

    The kinetic energy that occurs when energetic materials are impacted can be converted to heat through dissipative deformation processes while the macroscopic temperature remains unaffected. In this study, a thermodynamics-based approach was used to model the elasto-plastic behaviour that occurs during the deformation process of microstructures. Macroscopic material was modelled as a statistical distribution of unit cells containing a crack grain embedded in an elastic mortar-like matrix. A mesoscopic unit cell model was also developed under confined shear. The study demonstrated that stored energy is a non-negligible part of the total energy of the system, and that stored energy can be released during the unloading process. It was concluded that the mesoscopic analysis of the cracked cell demonstrates that continuum thermodynamics can be used to predict hot spots induced by friction. 7 refs., 7 figs.

  18. Bioaccessibility and Risk of Exposure to Metals and SVOCs in Artificial Turf Field Fill Materials and Fibers.

    Science.gov (United States)

    Pavilonis, Brian T; Weisel, Clifford P; Buckley, Brian; Lioy, Paul J

    2014-01-01

    To reduce maintenance costs, municipalities and schools are starting to replace natural grass fields with a new generation synthetic turf. Unlike Astro-Turf, which was first introduced in the 1960s, synthetic field turf provides more cushioning to athletes. Part of this cushioning comes from materials like crumb rubber infill, which is manufactured from recycled tires and may contain a variety of chemicals. The goal of this study was to evaluate potential exposures from playing on artificial turf fields and associated risks to trace metals, semi-volatile organic compounds (SVOCs), and polycyclic aromatic hydrocarbons (PAHs) by examining typical artificial turf fibers (n = 8), different types of infill (n = 8), and samples from actual fields (n = 7). Three artificial biofluids were prepared, which included: lung, sweat, and digestive fluids. Artificial biofluids were hypothesized to yield a more representative estimation of dose than the levels obtained from total extraction methods. PAHs were routinely below the limit of detection across all three biofluids, precluding completion of a meaningful risk assessment. No SVOCs were identified at quantifiable levels in any extracts based on a match of their mass spectrum to compounds that are regulated in soil. The metals were measurable but at concentrations for which human health risk was estimated to be low. The study demonstrated that for the products and fields we tested, exposure to infill and artificial turf was generally considered de minimus, with the possible exception of lead for some fields and materials. © 2013 Society for Risk Analysis.

  19. Bio-accessibility and Risk of Exposure to Metals and SVOCs in Artificial Turf Field Fill Materials and Fibers

    Science.gov (United States)

    Pavilonis, Brian T.; Weisel, Clifford P.; Buckley, Brian; Lioy, Paul J.

    2014-01-01

    To reduce maintenance costs, municipalities and schools are starting to replace natural grass fields with a new generation synthetic turf. Unlike Astro-Turf, which was first introduced in the 1960’s, synthetic field turf provides more cushioning to athletes. Part of this cushioning comes from materials like crumb rubber infill, which is manufactured from recycled tires and may contain a variety of chemicals. The goal of this study was to evaluate potential exposures from playing on artificial turf fields and associated risks to trace metals, semivolatile organic compounds (SVOCs), and polycyclic aromatic hydrocarbons (PAHs) by examining typical artificial turf fibers (n=8), different types of infill (n=8), and samples from actual fields (n=7). Three artificial biofluids were prepared which included: lung, sweat, and digestive fluids. Artificial biofluids were hypothesized to yield a more representative estimation of dose than the levels obtained from total extraction methods. PAHs were routinely below the limit of detection across all three biofluids precluding completion of a meaningful risk assessment. No SVOCs were identified at quantifiable levels in any extracts based on a match of their mass spectrum to compounds that are regulated in soil. The metals were measurable but at concentrations for which human health risk was estimated to be low. The study demonstrated that for the products and fields we tested, exposure to infill and artificial turf was generally considered de minimus, with the possible exception of lead for some fields and materials. PMID:23758133

  20. Additive Manufacturing of Metallic and Ceramic Components by the Material Extrusion of Highly-Filled Polymers: A Review and Future Perspectives

    Science.gov (United States)

    Cano, Santiago

    2018-01-01

    Additive manufacturing (AM) is the fabrication of real three-dimensional objects from metals, ceramics, or plastics by adding material, usually as layers. There are several variants of AM; among them material extrusion (ME) is one of the most versatile and widely used. In MEAM, molten or viscous materials are pushed through an orifice and are selectively deposited as strands to form stacked layers and subsequently a three-dimensional object. The commonly used materials for MEAM are thermoplastic polymers and particulate composites; however, recently innovative formulations of highly-filled polymers (HP) with metals or ceramics have also been made available. MEAM with HP is an indirect process, which uses sacrificial polymeric binders to shape metallic and ceramic components. After removing the binder, the powder particles are fused together in a conventional sintering step. In this review the different types of MEAM techniques and relevant industrial approaches for the fabrication of metallic and ceramic components are described. The composition of certain HP binder systems and powders are presented; the methods of compounding and filament making HP are explained; the stages of shaping, debinding, and sintering are discussed; and finally a comparison of the parts produced via MEAM-HP with those produced via other manufacturing techniques is presented. PMID:29783705

  1. Additive Manufacturing of Metallic and Ceramic Components by the Material Extrusion of Highly-Filled Polymers: A Review and Future Perspectives.

    Science.gov (United States)

    Gonzalez-Gutierrez, Joamin; Cano, Santiago; Schuschnigg, Stephan; Kukla, Christian; Sapkota, Janak; Holzer, Clemens

    2018-05-18

    Additive manufacturing (AM) is the fabrication of real three-dimensional objects from metals, ceramics, or plastics by adding material, usually as layers. There are several variants of AM; among them material extrusion (ME) is one of the most versatile and widely used. In MEAM, molten or viscous materials are pushed through an orifice and are selectively deposited as strands to form stacked layers and subsequently a three-dimensional object. The commonly used materials for MEAM are thermoplastic polymers and particulate composites; however, recently innovative formulations of highly-filled polymers (HP) with metals or ceramics have also been made available. MEAM with HP is an indirect process, which uses sacrificial polymeric binders to shape metallic and ceramic components. After removing the binder, the powder particles are fused together in a conventional sintering step. In this review the different types of MEAM techniques and relevant industrial approaches for the fabrication of metallic and ceramic components are described. The composition of certain HP binder systems and powders are presented; the methods of compounding and filament making HP are explained; the stages of shaping, debinding, and sintering are discussed; and finally a comparison of the parts produced via MEAM-HP with those produced via other manufacturing techniques is presented.

  2. Assessment of exposure to chemical agents in in fill material for artificial turf soccer pitches: development and implementation of a survey protocol

    International Nuclear Information System (INIS)

    Castellano, P.; Proietto, A.R.; Gordiani, A.; Ferrante, R.; Tranfo, G.; Paci, E.; Pigini, D.

    2008-01-01

    Health concerns over the composition of the in fill material used to construct artificial turf pitches (e.g., for soccer and rugby), raised the need to develop a specific procedure to assess the risks of human exposure to pollutants that may be released by these materials. The aim of this paper was to develop and implement a survey protocol to assess exposure of artificial turf pitches users (e.g., coaches and maintenance personnel) through environmental and biological monitoring of toxic and carcinogenic substances contained in some types of in fill materials for artificial turf pitches. The exposure was assessed by personal and environmental sampling of hazardous substances - particularly of benzene, toluene, xylene (BTX), polycyclic aromatic hydrocarbons (PAHs) and heavy metals (lead, cadmium, chromium, tin and zinc) - for comparison with the occupational exposure limit values as per the Italian regulations and the lists of the American Conference of Industrial Governmental Hygienists (ACGIH). In addition, biological monitoring was performed for the quantitative and qualitative determination of the exposure bio markers of the substances of interest in potentially exposed individuals and in control group. Environmental sampling was performed on an outdoor, artificial turf soccer pitch in a sports facility in Rome characterized by recycled in fill material (rubber granules from recycled tyres, without any further processing); suction pumps were used as environmental samplers to collect the samples (located in areas of the soccer pitch deemed representative of exposure conditions) and personal samplers (in this latter case exclusively for monitoring PAHs) worn by the coaches during training sessions. For the various substances the following sampling systems were used: vials for BTX (benzene, toluene, and xylene), filters for metals and combined systems (filter plus vial) for the PAHs. The extracts were then analyzed by various instrumental techniques such as gas

  3. Cytotoxicity and Initial Biocompatibility of Endodontic Biomaterials (MTA and Biodentine™) Used as Root-End Filling Materials.

    Science.gov (United States)

    Escobar-García, Diana María; Aguirre-López, Eva; Méndez-González, Verónica; Pozos-Guillén, Amaury

    2016-01-01

    Objective. The aim of this study was to evaluate the cytotoxicity and cellular adhesion of Mineral Trioxide Aggregate (MTA) and Biodentine (BD) on periodontal ligament fibroblasts (PDL). Methods. PDL cells were obtained from nonerupted third molars and cultured; MTS cellular profusion test was carried out in two groups: MTA and BD, with respective controls at different time periods. Also, the LIVE/DEAD assay was performed at 24 h. For evaluation of cellular adhesion, immunocytochemistry was conducted to discern the expression of Integrin β1 and Vinculin at 12 h and 24 h. Statistical analysis was performed by the Kruskal-Wallis and Mann-Whitney U tests. Results. MTA and BD exhibited living cells up to 7 days. More expressions of Integrin β1 and Vinculin were demonstrated in the control group, followed by BD and MTA, which also showed cellular loss and morphological changes. There was a significant difference in the experimental groups cultured for 5 and 7 days compared with the control, but there was no significant statistical difference between both cements. Conclusions. Neither material was cytotoxic during the time evaluated. There was an increase of cell adhesion through the expression of focal contacts observed in the case of BD, followed by MTA, but not significantly.

  4. An interview study of persons who attribute health problems to dental filling materials--part two in a triangulation study on 65 and 75 years old Swedes.

    Science.gov (United States)

    Ståhlnacke, Katri; Söderfeldt, Björn

    2013-01-01

    Dental materials are perceived as a health problem by some people, although scientists do not agree about possible causes of such problems. The aim of this paper was to gain a deeper knowledge and understanding of experiences from living with health problems attributed to dental materials. Addressed topics were the type of problem, both as to general and oral health, perceived causes of the problems,their experienced effect on life, and reception by health professionals. Persons, who in a previous large questionnaire study had answered that they had experienced troubles from dental materials and also agreed to answer follow-up questions, were contacted with a request to take part in an interview study. Eleven individual interviews were held.The interviews were transcribed verbatim and the material was analysed according to the Qualitative Content Analysis method. Meaning units were extracted and condensed into a number of codes, which were combined into subcategories, categories, and themes. Four themes were identified: 1) Long-term oral, mental, and somatic difficulties of varying character, caused by dental amalgam. 2) Problems treated mainly by replacement of dental material in fillings. 3) Powerful effects on life, mostly negative. 4) The reception by health professionals was generally good, but with elements of encounters where they felt treated with nonchalance and lack of respect. In conclusion, people who attributed their health difficulties to dental materials had a complex range of problems and the perception was that amalgam/mercury was the cause of the troubles. The reception from health professionals was perceived as generally good, although with occasional negative experiences.

  5. Combined effects of nonparaxiality, optical activity, and walk-off on rogue wave propagation in optical fibers filled with chiral materials

    Science.gov (United States)

    Temgoua, D. D. Estelle; Tchokonte, M. B. Tchoula; Kofane, T. C.

    2018-04-01

    The generalized nonparaxial nonlinear Schrödinger (NLS) equation in optical fibers filled with chiral materials is reduced to the higher-order integrable Hirota equation. Based on the modified Darboux transformation method, the nonparaxial chiral optical rogue waves are constructed from the scalar model with modulated coefficients. We show that the parameters of nonparaxiality, third-order dispersion, and differential gain or loss term are the main keys to control the amplitude, linear, and nonlinear effects in the model. Moreover, the influence of nonparaxiality, optical activity, and walk-off effect are also evidenced under the defocusing and focusing regimes of the vector nonparaxial NLS equations with constant and modulated coefficients. Through an algorithm scheme of wider applicability on nonparaxial beam propagation methods, the most influential effect and the simultaneous controllability of combined effects are underlined, showing their properties and their potential applications in optical fibers and in a variety of complex dynamical systems.

  6. Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments

    Directory of Open Access Journals (Sweden)

    Taha Özyürek

    2017-11-01

    Full Text Available Objectives To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR, Mtwo-R, ProTaper Next (PTN, and Twisted File Adaptive (TFA systems. Materials and Methods The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU, Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with χ2 tests using SPSS 21.0 software. Results New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. Conclusions This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.

  7. Selection and specification criteria for fills for cut-and-fill mining

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, E. G.

    1980-05-15

    Because of significant differences in placement and loading conditions, the ideal fill material for a cut-and-fill operation has different characteristics to those for a fill for a filled open stoping operation. The differing requirements of the two mining operations must be understood and accounted for in establishing fill selection and specification criteria. Within the paper, aspects of the particular requirements of cut-and-fill mining are analyzed and related to the specific fill tests and properties required. Emphasis is placed upon the role of fill in ground support, though this cannot be isolated from overall fill performance. Where appropriate, test data are introduced and areas requiring continuing research highlighted.

  8. Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments.

    Science.gov (United States)

    Özyürek, Taha; Tek, Vildan; Yılmaz, Koray; Uslu, Gülşah

    2017-11-01

    To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with χ 2 tests using SPSS 21.0 software. New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.

  9. Effect of Flapless Immediate Implantation and Filling the Buccal Gap with Xenograft Material on the Buccal Bone Level: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Mojgan Paknejad

    2017-12-01

    Full Text Available Objectives: Following tooth extraction, soft and hard tissue alterations occur; Different factors can affect this process. The objective of this study was to determine the effect of gap filling on buccal alveolar crestal bone level after immediate implant placement after 4- to 6-month observation period.Materials and Methods: This   randomized clinical trial was performed on 20 patients (mean age of 38.8 years requiring tooth extraction in a total of 27 areas in the anterior maxilla. The treatment strategy was as follows: atraumatic flapless tooth extraction, implant placement, insertion of a graft (test group or no material (control group between the implant and the socket wall, connection healing abutment placement and suturing the area. Clinical and cone beam computed tomographic examinations were performed before implant placement (baseline, 24 hours after surgery and 4-6 months (T2 after implant placement, to assess the buccal plate height (BH and implant complications.Results: After 4 months of healing, a reduction in different bone measurements was noticed in the two groups. No statistically significant differences were assessed in bone height measurements between the test and control groups at different time points. The study demonstrated that immediate implantation resulted in 1.30 and 1.66 mm reduction in buccal bone plate in the test and control groups, respectively.Conclusions: The study demonstrated that immediate implantation in the extraction socket together with xenograft failed to prevent bone resorption.

  10. Enhancement of open-circuit voltage and the fill factor in CdTe nanocrystal solar cells by using interface materials

    International Nuclear Information System (INIS)

    Zhu, Jiaoyan; Yang, Yuehua; Gao, Yuping; Qin, Donghuan; Wu, Hongbin; Huang, Wenbo; Hou, Lintao

    2014-01-01

    Interface states influence the operation of nanocrystal (NC) solar cell carrier transport, recombination and energetic mechanisms. In a typical CdTe NC solar cell with a normal structure of a ITO/p-CdTe NCs/n-acceptor (or without)/Al configuration, the contact between the ITO and CdTe is a non-ohm contact due to a different work function (for an ITO, the value is ∼4.7 eV, while for CdTe NCs, the value is ∼5.3 eV), which results in an energetic barrier at the ITO/CdTe interface and decreases the performance of the NC solar cells. This work investigates how interface materials (including Au, MoO x and C 60 ) affect the performance of NC solar cells. It is found that devices with interface materials have shown higher V oc than those without interface materials. For the case in which we used Au as an interface, we obtained a high open-circuit voltage of 0.65 V, coupled with a high fill factor (62%); this resulted in a higher energy conversion efficiency (ECE) of 5.3%, which showed a 30% increase in the ECE compared with those without the interlayer. The capacitance measurements indicate that the increased V oc in the case in which Au was used as the interface is likely due to good ohm contact between the Au’s and the CdTe NCs’ thin film, which decreases the energetic barrier at the ITO/CdTe interface. (paper)

  11. Part 3: Medico-legal documentation Practical completion of pages 2 ...

    African Journals Online (AJOL)

    for medical indications and to detect foreign objects in adults ..... development in rural and urban South African black children. Ann Hum Biol. 1993 .... Darnell C. Forensic science in healthcare: caring for patients, preserving the evidence.

  12. [The issue of medico-legal assessment of noise induced hearing loss: comparison of methods].

    Science.gov (United States)

    Bosio, D; Coggiola, M; Baracco, A; Andreis, P; Perrelli, F

    2011-01-01

    Audiogram classification is crucial for hearing protection of workers occupationally exposed to noise. The methods that have been proposed are based on two principles: the morphological evaluation of the audiometric curve (eg. Merluzzi-Pira-Bosio--MPB) or the average hearing loss on different frequencies (eg. Albera-Beatrice--AB). The purpose of this study was to classify audiograms compatible with chronic acoustic trauma performed at the Occupational Medicine Outpatient Clinic of CTO Hospital in Turin from 2004 to 2011 with the methods outlined in Guidelines published by SIMLII. A substantial agreement among the methods was observed. While MPB is the most appropriate method for secondary prevention, the AB would seem more appropriate for the verification of a permanent weakening that has to be reported to the competent legal authorities.

  13. Radiological informed consent in cardiovascular imaging: towards the medico-legal perfect storm?

    Directory of Open Access Journals (Sweden)

    Loré Cosimo

    2007-10-01

    Full Text Available Abstract Use of radiation for medical examinations and tests is the largest manmade source of radiation exposure. No one can doubt the immense clinical and scientific benefits of imaging to the modern practice of medicine. Every radiological and nuclear medicine examination confers a definite (albeit low long-term risk of cancer, but patients undergoing such examinations often receive no or inaccurate information about radiological dose exposure and corresponding risk directly related to the radiological dose received. Too detailed information on radiological dose and risk may result in undue anxiety, but information "economical with the truth" may violate basic patients' rights well embedded in ethics (Oviedo convention 1997 and law (97/43 Euratom Directive 1997. Informed consent is a procedure needed to establish a respectful and ethical relation between doctors and patients. Nevertheless, in an "ideal" consent process, the principle of patient autonomy in current radiological practice might be reinforced by making it mandatory to obtain explicit and transparent informed consent form for radiological examination with high exposure (≥ 500 chest x-rays. The form may spell-out the type of examination, the exposure in effective dose (mSv, derived from reference values in guidelines or – better – from actual values from their department. The dose equivalent might be also expressed in number of chest radiographs and the risk of cancer as number of extra cases in the exposed population, derived from most recent and authorative guidelines (e.g., BEIR VII Committee, release 2006. Common sense, deontological code, patients'rights, medical imaging guidelines, Euratom law, all coherently and concordantly encourage and recommend a justified, optimized, responsible and informed use of testing with ionizing radiation. Although the idea of informed consent for radiation dose does not seem to be on the immediate radar screen at least in the US, the current practice clashes against these guidelines and laws.

  14. Medico-legal implications of sleep apnoea syndrome: Driving license regulations in Europe

    DEFF Research Database (Denmark)

    Alonderis, A.; Barbee, F.; Bonsignore, M.

    2008-01-01

    Background: Sleep apnoea syndrome (SAS), one of the main medical causes of excessive daytime sleepiness, has been shown to be a risk factor for traffic accidents. Treating SAS results in a normalized rate of traffic accidents. As part of the COST Action B-26, we looked at driving license regulati......Background: Sleep apnoea syndrome (SAS), one of the main medical causes of excessive daytime sleepiness, has been shown to be a risk factor for traffic accidents. Treating SAS results in a normalized rate of traffic accidents. As part of the COST Action B-26, we looked at driving license...... sleep apnoea syndrome is mentioned in 10 countries. A patient with untreated sleep apnoea is always considered unfit to drive. To recover the driving capacity, seven countries rely on a physician's medical certificate based on symptom control and compliance with therapy, whereas in two countries...... it is up to the patient to decide (on his doctor's advice) to drive again. Only FR requires a normalized electroencephalography (EEG)-based Maintenance of Wakefulness Test for professional drivers. Rare conditions (e.g., narcolepsy) are considered a driving safety risk more frequently than sleep apnoea...

  15. Death from Barotrauma Due to Compressed Air: A Medico-legal Analysis.

    Science.gov (United States)

    Giugliano, Pasquale; Massoni, Francesco; Crisci, Antonello; Ricci, Serafino

    2016-11-01

    Lesions of the digestive tract due to barotrauma resulting from compressed air application are not common, are rarely lethal, and largely affect the sigmoid and descending colon. Moreover, their pathogenic mechanism is a topic of discussion because these lesions have multiple characteristics. Here, the authors describe an autoptic case of death from lesions of the ascending and transverse segments, with perforations and bleeding suffusions as well as ischemic areas covered the colonic wall that was extremely thinned, congested, and hemorrhagic, with considerable flattening leading to disappearance of the mucosal folds and with numerous petechial hemorrhages. The pathological framework of lung congestion made it possible to identify the mechanism responsible for this death as depletion of the heart's pumping function, which contributed significantly to the acute respiratory failure due to respiratory distress as well as to reduced mobility of the diaphragm due to intestinal distension. Acute heart failure played an important role in this death. © 2016 American Academy of Forensic Sciences.

  16. medico-legal an overview of some of the key legal developments in ...

    African Journals Online (AJOL)

    Enrique

    equipped to admit a child with HIV as none of its teachers ... Head, Legal Unit, AIDS Law Project, and Centre for Applied Legal Studies, University of the Witwatersrand, Johannesburg ... once they have certified that the test or treatment is in the.

  17. Part 3: Medico-legal documentation Practical completion of pages 2 ...

    African Journals Online (AJOL)

    revision so that the research and advances in knowledge that have taken place .... the female breasts, and not the menarche.3 The information is of medical value in .... Examination on a lap makes the prone knee-chest position difficult, but not.

  18. The ethical and medico-legal issues of trauma care | Hardcastle ...

    African Journals Online (AJOL)

    Abstract. Ethical issues confront trauma clinicians on a daily basis. This article highlights the similarities of trauma ethical dilemmas to those faced by other emergency care providers and takes the reader through the inpatient aspects of trauma care.

  19. Part 2: Medico-legal documentation Practical completion of pages 1 ...

    African Journals Online (AJOL)

    Part 3 will address the sexual assault section of the J88 form. As a legal document, ... shown that suspects can manipulate crucial biological results and examinations to ..... of speech, and orientation with regard to the time, place and person.3.

  20. Breakdowns in communication of radiological findings: an ethical and medico-legal conundrum

    OpenAIRE

    Berlin, Leonard; Murphy, Daniel R.; Singh, Hardeep

    2014-01-01

    Communication problems in diagnostic testing have increased in both number and importance in recent years. The medical and legal impact of failure of communication is dramatic. Over the past decades, the courts have expanded and strengthened the duty imposed on radiologists to timely communicate radiologic abnormalities to referring physicians and perhaps the patients themselves in certain situations. The need to communicate these findings goes beyond strict legal requirements: there is a mor...

  1. Breakdowns in communication of radiological findings: an ethical and medico-legal conundrum.

    Science.gov (United States)

    Berlin, Leonard; Murphy, Daniel R; Singh, Hardeep

    2014-12-01

    Communication problems in diagnostic testing have increased in both number and importance in recent years. The medical and legal impact of failure of communication is dramatic. Over the past decades, the courts have expanded and strengthened the duty imposed on radiologists to timely communicate radiologic abnormalities to referring physicians and perhaps the patients themselves in certain situations. The need to communicate these findings goes beyond strict legal requirements: there is a moral imperative as well. The Code of Medical Ethics of the American Medical Association points out that "Ethical values and legal principles are usually closely related, but ethical obligations typically exceed legal duties." Thus, from the perspective of the law, radiologists are required to communicate important unexpected findings to referring physicians in a timely fashion, or alternatively to the patients themselves. From a moral perspective, radiologists should want to effect such communications. Practice standards, moral values, and ethical statements from professional medical societies call for full disclosure of medical errors to patients affected by them. Surveys of radiologists and non-radiologic physicians reveal that only few would divulge all aspects of the error to the patient. In order to encourage physicians to disclose errors to patients and assist in protecting them in some manner if malpractice litigation follows, more than 35 states have passed laws that do not allow a physician's admission of an error and apologetic statements to be revealed in the courtroom. Whether such disclosure increases or decreases the likelihood of a medical malpractice lawsuit is unclear, but ethical and moral considerations enjoin physicians to disclose errors and offer apologies.

  2. The Development of the Interface between Law, Medicine and Psychiatry: Medico-Legal Perspectives in History

    Directory of Open Access Journals (Sweden)

    M Swanepoel

    2009-12-01

    Full Text Available Medicine and law were related from early times. This relation resulted as a necessity of protecting communities from the irresponsible acts of impostors. Various legal codes dealing with medical malpractice existed in Egypt, Mesopotamia, China, Islam, Greece, Rome, Persia and India. Over the course of the past 30 years, interest in the history of psychiatry has boomed. Much of this proliferation of interest has taken place under the broad influence of postmodernism and has resulted in multiple and diverse histories that no longer seek to provide a linear narrative of constant evolutionary progress. Rather, these new histories explore and disrupt taken for granted assumptions about the past and provide a starting point for discussion and debate about the some of the very foundations of mental health care in South Africa. As a matter of practical importance knowledge of how knowledge accrues and knowledge of the mistakes of the past is of prime importance in preventing similar mistakes in present and future work. An important reason for specifically understanding historical psychiatry is the fact that many of the uncertainties experienced in the present are a direct result of decisions made in the past. The key issue is that while it is tempting to experience current psychiatric and legal approaches towards the mentally disordered as natural and permanent, an understanding of the past helps mental health and legal practitioners to see things in a different perspective. Psychiatric and legal approaches towards the mentally disordered have changed over time and can undoubtedly also be changed in future. Therefore, the research conducted in this article focuses on the history and development of law and psychiatry including prehistoric times, the Arabian countries, the Nile Valley as well as Greece and Rome.

  3. IGF-1 abuse in sport: clinical and medico-legal aspects.

    Science.gov (United States)

    Molinelli, A; Bonsignore, A; Cicconi, M; Cioè, A; Traverso, A

    2010-12-01

    The frequent revisions of prohibited substances list established by WADA are aimed at keeping up with those drugs that, being increasingly used in medicine and in sports, play on one side a therapeutic role and, on the other, a doping role. Among the various hormone substances widely used in sports, the authors draw particular attention on IGF-1, a growth factor that is rapidly widespreading among athletes. Moreover, IGF-1 diffusion is not exclusively correlated with the doping phenomenon, being various the pathological conditions that may require the therapeutic use of this substance. As a consequence, during pathologies or medical treatments of various nature, the athletes should be informed of the IGF-1 administration because, if they are not duly apprised, they risk undergoing unjust sanctions from the competent authority. In fact, the athlete is given the possibility of communicating, before using, he is taking a medication of the WADA list for therapeutic reasons by applying for a TUE (Therapeutic Use Exemption). If this application is accepted on certified clinical grounds, the athlete will be allowed to use that substance even during sports competitions. However, the IGF-1 detection in the athlete's body shows, at the present state-of-art, two different problems: the first one has a technical character and concerns the differential diagnosis between the quantity of the physiologically produced substance and the quantity of the exogenously administrated substance; the second problem has an economic character and regards to the high cost of the analysis and, consecutively, the necessity of finding a well-equipped laboratory centre.

  4. MEDICO-LEGAL HIV/AIDS, LAW AND ETHICS: A BRIEF ANALYSIS ...

    African Journals Online (AJOL)

    Enrique

    ... are in a unique situation, as both legal and ethical rules apply to a ... Guidelines for the Management of Patients with HIV. Infection or ... process of obtaining informed consent from a patient. Not ... narrowly construed and applied. Although ...

  5. Medico-legal implications of mobbing. A false accusation of psychological harassment at the workplace.

    Science.gov (United States)

    Jarreta, Begoña Martínez; García-Campayo, Javier; Gascón, Santiago; Bolea, Miguel

    2004-12-02

    Mobbing, or psychological harassment at the workplace, is usually defined as a situation in which a person or a group of people engage in extreme psychological violence against another person. In Spain, the number of reports for mobbing has increased extraordinarily in the last years. The reports are increasing dramatically not only before the Labour Courts, but also before the Civil Courts, with claims for damages, and before the Penal Court for offences causing physical or moral injury, etc., since at the present time this figure is not typified as an offence in the Spanish Penal Code. The high degree of complexity of this situation has given rise to frequent misuse of the term and to a number of false accusations of mobbing. A recent European Parliament Resolution on harassment at the workplace addressed the devastating consequences of false accusations. In this paper we present a case in which the "false" victim was mentally ill (paranoia) but succeed in generating an extreme dangerous environment of great harassment against the "false" assailants that were "falsely" accused of mobbing. Forensic diagnosis of the psychiatric disorder suffered by the "false" victim was essential to clarify the issue at the Penal Court.

  6. Diptera of Medico-Legal Importance Associated With Pig Carrion in a Tropical Dry Forest.

    Science.gov (United States)

    Vasconcelos, S D; Salgado, R L; Barbosa, T M; Souza, J R B

    2016-06-20

    The diversity of necrophagous Diptera is largely unknown in seasonally dry tropical forests, despite their medical, veterinary, and forensic relevance. We performed a study in the dry Caatinga forest exclusive to Brazil in order to assess the diversity and temporal pattern of Diptera species using pig carcasses as substrates. Adults were collected daily until complete skeletonization. We collected 17,142 adults from 18 families, 10 of which comprise species with known necrophagous habits. The most abundant families were Calliphoridae (47.3% of specimens), Sarcophagidae (20.8%), and Muscidae (15.5%), whereas Sarcophagidae stood out in terms of richness with 21 species. The native Cochliomyia macellaria (F.) (Diptera: Calliphoridae) and the invasive Chrysomya albiceps (Wiedmann) (Calliphoridae) were the dominant species. A total of 18 species reached the carcass during the first 48 h postdeath. The bloated and active decay stages had the highest richness and abundance of dipterans. From a forensic standpoint, C. macellaria and C. albiceps are likely to aid in establishing postmortem interval due to their early arrival and high abundance on the carcass. Despite harsh environmental conditions, the Caatinga harbors a rich assemblage of dipterans that play a key role in carrion decomposition. Their medico-veterinary importance is strengthened by the poor local sanitary conditions. © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Piercing and tattoos in adolescents: legal and medico-legal implications

    Directory of Open Access Journals (Sweden)

    Conti Adelaide

    2018-04-01

    Full Text Available Non-therapeutic body modification interventions are permitted within the limits of the use of one’s own body that can be specified in the legal system. The authors take into consideration Italian regulation on tattooing and piercing, in particular in relation to adolescents.

  8. Piercing and Tattoos in Adolescents: Legal and Medico-legal Implications.

    Science.gov (United States)

    Conti, Adelaide; Bin, Paola; Casella, Claudia; Capasso, Emanuele; Fedeli, Piergiorgio; Salzano, Francesco Antonio; Terracciano, Lucia; Piras, Mauro

    2018-01-01

    Non-therapeutic body modification interventions are permitted within the limits of the use of one's own body that can be specified in the legal system. The authors take into consideration Italian regulation on tattooing and piercing, in particular in relation to adolescents. In Italy, several regions have therefore issued acts aimed at regulating the activities of tattoo and piercing also in reference to minors. Discussion. With regard to minors, the rules taken into account set precise limits in relation to the age criterion and subordinate the implementation of such practices to the provision of consent by legal representatives. If such practices are of an aesthetic nature, we cannot avoid considering the implications they have on health protection, and then adopt appropriate measures to protect the person who intends to undergo them, particularly in the case of minors.

  9. Medico-legal analysis of a case of mass shooting

    Directory of Open Access Journals (Sweden)

    Roman Kuruc

    2014-12-01

    Full Text Available Despite the existence of organised crime in Slovakia, no case has ever been monitored in which one individual used a firearm against several people, as happens in the U.S. or in Western Europe. The aim of this work is to demonstrate a “unique” case in the history of Slovak criminality, when six members of one family were killed and some other accidental victims were wounded or even killed by one perpetrator using a firearm.

  10. Survey of medico-legal investigation of homicide in the region of Epirus (Northwest Greece).

    Science.gov (United States)

    Fragkouli, Kleio; Boumba, Vassiliki; Vougiouklakis, Theodore

    2016-01-01

    This study analyzed the forensic features of homicides in North-West Greece (Epirus) from 1998 to 2013, a borderland area between Greece and Albania. Although Greece is critically influenced by both the increasing flow of refugees and the current socioeconomic crisis, very little information has been published regarding the patterns of homicide in the country. Fifty-eight autopsied victims (36 males; 22 females) were investigated. The median age was 37 years old. The average annual homicide rate was 0.85 per 100,000 inhabitants and showed remarkable fluctuation, with largest increase during Greek financial downturn. Sixteen victims were not Greek citizens. The most common method of commitment was the use of firearm (40%). The main motives were economical causes (26%) and passion (14%). Four cases were categorized as matricide (7%), 3 as homicide-suicide (5%), 2 as patricide (3%) and 1 as infanticide (2%). Toxicological analysis proved negative for ethanol and other psychotropic substances in the majority of the victims (50%). There is an urgent need for public actions both in Epirus and in Greece, with the application of effective strategies against criminality. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  11. A Management Guide to Asbestos: Medico-Legal, Regulatory, and Hazard Abatement Considerations

    Science.gov (United States)

    1986-08-01

    of the medical hazards of asbestos exposure. Essentially, plaintiffs suffer from a failure of the courts to apply the doctrine of collateral estoppel ...93-114. Brennan, Troyen A, "Collateral Estoppel in Asbestos Litigation." Environmental Law 14 (1983): 197-222. Brodeur, Paul. ’The Asbestos

  12. HANNIBAL REVISITED: ANTISOCIAL PERSONALITY DISORDER VERSUS PSYCHOPATHY--MEDICO-LEGAL PERSPECTIVES FROM SOUTH AFRICA.

    Science.gov (United States)

    Stevens, Philip

    2014-07-01

    Psychopathy and its relation to criminal behaviour has been the focus of clinical research for many years. Within the context of South African criminal law, the impact of psychopathy on criminal liability has been addressed in numerous decisions with varying outcomes all indicative of the reality that psychopathy will at most serve as a factor in mitigation of sentence, but will not exonerate an accused of criminal responsibility. In this contribution, the author reflects on the diagnostic entities of psychopathy and antisocial personality disorder against the backdrop of South African criminal law cases in terms of which either of these entities were raised in support of mitigation of sentence and/or as extenuating circumstances.

  13. Medical advancements: emergency contraception (EC). Medico-legal implications of EC on adolescents.

    Science.gov (United States)

    Signore, F; Napoletano, S; Bruti, V; di Luca, N M

    2018-01-01

    The article's main focus is documenting what the best options are in order to make sure that minors are allowed to play a key role in the management of issues arising from the use of emergency contraception. In that regard, there is a lack of clean-cut legislative measures and, although there are several legal and ethical norms designed to get parents or legal guardians involved in such decisions, there seems to be an increasingly widespread tendency to give weight to the minor's will, thus acknowledging her decision-making capacity. Lastly, the paper's authors undertake a thorough examination as to what the duties of doctors are, and the measures that need to be put in place in order to safeguard the minor patients' conditions. They arrive at the conclusion that emergency contraception is suitable for minors even in absence of the stated consent from their parents or guardians, but it is of utmost importance to implement adequate measures aimed at the provision of proper care, prevention and education.

  14. Piercing and Tattoos in Adolescents: Legal and Medico-legal Implications

    Science.gov (United States)

    Conti, Adelaide; Bin, Paola; Casella, Claudia; Capasso, Emanuele; Fedeli, Piergiorgio; Salzano, Francesco Antonio; Terracciano, Lucia; Piras, Mauro

    2018-01-01

    Abstract Non-therapeutic body modification interventions are permitted within the limits of the use of one’s own body that can be specified in the legal system. The authors take into consideration Italian regulation on tattooing and piercing, in particular in relation to adolescents. Results In Italy, several regions have therefore issued acts aimed at regulating the activities of tattoo and piercing also in reference to minors. Discussion. With regard to minors, the rules taken into account set precise limits in relation to the age criterion and subordinate the implementation of such practices to the provision of consent by legal representatives. Conclusion If such practices are of an aesthetic nature, we cannot avoid considering the implications they have on health protection, and then adopt appropriate measures to protect the person who intends to undergo them, particularly in the case of minors. PMID:29675481

  15. Efficacy of CM-Wire, M-Wire, and Nickel-Titanium Instruments for Removing Filling Material from Curved Root Canals: A Micro-Computed Tomography Study.

    Science.gov (United States)

    Rodrigues, Clarissa Teles; Duarte, Marco Antonio Hungaro; de Almeida, Marcela Milanezi; de Andrade, Flaviana Bombarda; Bernardineli, Norberti

    2016-11-01

    The aim of this ex vivo study was to evaluate the removal of filling material after using CM-wire, M-wire, and nickel-titanium instruments in both reciprocating and rotary motions in curved canals. Thirty maxillary lateral incisors were divided into 9 groups according to retreatment procedures: Reciproc R25 followed by Mtwo 40/.04 and ProDesign Logic 50/.01 files; ProDesign R 25/.06 followed by ProDesign Logic 40/.05 and ProDesign Logic 50/.01 files; and Gates-Glidden drills, Hedström files, and K-files up to apical size 30 followed by K-file 40 and K-file 50 up to the working length. Micro-computed tomography scans were performed before and after each reinstrumentation procedure to evaluate root canal filling removal. Statistical analysis was performed with Kruskal-Wallis, Friedman, and Wilcoxon tests (P < .05). No significant differences in filling material removal were found in the 3 groups of teeth. The use of Mtwo and ProDesign Logic 40/.05 rotary files did not enhance filling material removal after the use of reciprocating files. The use of ProDesign Logic 50/.01 files significantly reduced the amount of filling material at the apical levels compared with the use of reciprocating files. Association of reciprocating and rotary files was capable of removing a large amount of filling material in the retreatment of curved canals, irrespective of the type of alloy of the instruments. The use of a ProDesign Logic 50/.01 file for apical preparation significantly reduced the amount of remnant material in the apical portion when compared with reciprocating instruments. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Mechanics of filled carbon nanotubes

    KAUST Repository

    Monteiro, A.O.; Cachim, P.B.; Da Costa, Pedro M. F. J.

    2014-01-01

    The benefits of filling carbon nanotubes (CNTs) with assorted molecular and crystalline substances have been investigated for the past two decades. Amongst the study of new structural phases, defects, chemical reactions and varied types of host-guest interactions, there is one fundamental characterisation aspect of these systems that continues to be overlooked: the mechanical behaviour of filled CNTs. In contrast to their empty counterparts, the mechanics of filled CNTs is a subject where reports appear far and apart, this despite being key to the application of these materials in technological devices. In the following paragraphs, we review the work that has been carried out up to the present on the mechanics of filled CNTs. The studies discussed range from experimental resonant frequency essays performed within electron microscopes to modelling, via molecular dynamics, of three-point bending of nanotubes filled with gases. (C) 2014 Elsevier B.V. All rights reserved.

  17. Mechanics of filled carbon nanotubes

    KAUST Repository

    Monteiro, A.O.

    2014-04-01

    The benefits of filling carbon nanotubes (CNTs) with assorted molecular and crystalline substances have been investigated for the past two decades. Amongst the study of new structural phases, defects, chemical reactions and varied types of host-guest interactions, there is one fundamental characterisation aspect of these systems that continues to be overlooked: the mechanical behaviour of filled CNTs. In contrast to their empty counterparts, the mechanics of filled CNTs is a subject where reports appear far and apart, this despite being key to the application of these materials in technological devices. In the following paragraphs, we review the work that has been carried out up to the present on the mechanics of filled CNTs. The studies discussed range from experimental resonant frequency essays performed within electron microscopes to modelling, via molecular dynamics, of three-point bending of nanotubes filled with gases. (C) 2014 Elsevier B.V. All rights reserved.

  18. Technology of hardening fills for mined spaces

    International Nuclear Information System (INIS)

    Simek, P.; Holas, M.; Chyla, A.; Pech, P.

    1985-01-01

    The technology is described of hardening fills for mined spaces of uranium deposits in North Bohemian chalk. A special equipment was developed for the controlled preparation of a hardening mixture. The composition of the fill is determined by the strength of the filled rock, expecially by the standard strength, i.e., the minimal strength of the filling under uniaxial pressure. The said parameter determines the consumption of binding materials and thereby the total costs of the filling. A description is presented of the filling technology, including rabbit tube transport of the mixture and quality control. (Pu)

  19. Fluoride release and recharge behavior of a nano-filled resin-modified glass ionomer compared with that of other fluoride releasing materials.

    Science.gov (United States)

    Mitra, Sumita B; Oxman, Joe D; Falsafi, Afshin; Ton, Tiffany T

    2011-12-01

    To compare the long-term fluoride release kinetics of a novel nano-filled two-paste resin-modified glass-ionomer (RMGI), Ketac Nano (KN) with that of two powder-liquid resin-modified glass-ionomers, Fuji II LC (FLC) and Vitremer (VT) and one conventional glass-ionomer, Fuji IX (FIX). Fluoride release was measured in vitro using ion-selective electrodes. Kinetic analysis was done using regression analysis and compared with existing models for GIs and compomers. In a separate experiment the samples of KN and two conventional glass-ionomers, FIX and Ketac Molar (KM) were subjected to a treatment with external fluoride source (Oral-B Neutra-Foam) after 3 months of fluoride release and the recharge behavior studied for an additional 7-day period. The cumulative amount of fluoride released from KN, VT and FLC and the release profiles were statistically similar but greater than that for FIX at P coating of KN with its primer and of DY with its adhesive did not significantly alter the fluoride release behavior of the respective materials. The overall rate for KN was significantly higher than for the compomer DY. DY showed a linear rate of release vs. t and no burst effect as expected for compomers. The nanoionomer KN showed fluoride recharge behavior similar to the conventional glass ionomers FIX and KM. Thus, it was concluded that the new RMGI KN exhibits fluoride ion release behavior similar to typical conventional and RMGIs and that the primer does not impede the release of fluoride.

  20. Study of 5f electron based filled skutterudite compound EuFe{sub 4}Sb{sub 12}, a thermoelectric (TE) material: FP-LAPW method

    Energy Technology Data Exchange (ETDEWEB)

    Shankar, A., E-mail: amitshan2009@gmail.com [Department of Physics, Mizoram University, Aizawl 796004 (India); Rai, D.P., E-mail: dibyaprakashrai@gmail.com [Beijing Computational Science Research Center, 3 Heqing Road, Beijing 100084 (China); Khenata, R. [Laboratoire de Physique Quantique et de Modlisation Mathmatique (LPQ3M), Dpartement de Technologie, Universit de Mascara, 29000 Mascara (Algeria); Maibam, J. [Department of Physics, Assam University, Silchar 788011 (India); Sandeep, E-mail: sndp.chettri@gmail.com [Department of Physics, Mizoram University, Aizawl 796004 (India); Thapa, R.K., E-mail: r.k.thapa@gmail.com [Department of Physics, Mizoram University, Aizawl 796004 (India)

    2015-01-15

    Highlights: • The compound EuFe{sub 4}Sb{sub 12} shows a semi-metallic behavior with pseudo gap. • The inherent dense band near E{sub F} facilitate the charge carriers. • The magnetic moment within LSDA and mBJ are underestimated. • The inclusion of onsite Coulomb repulsion (U) in LSDA has improved the result. • The results obtained from LSDA + U are consistent with the experimental data. - Abstract: We have studied the elastic, electronic and magnetic properties along with the thermoelectric properties of an undoped filled skutterudite EuFe{sub 4}Sb{sub 12} using full-potential linearized augmented plane wave (FP-LAPW) method. The LSDA, LSDA + U and a new exchange-correlation functional called modified Becke Johnson (mBJ) potential based on density functional theory (DFT) were used for studying material properties. The Eu-f and Fe-d are strongly correlated elements thus the inclusion of Coulomb repulsion (U) expected to give an exact ground state properties. The exchange-splitting of Eu-4f states were analyzed to explain the ferromagnetic behavior of EuFe{sub 4}Sb{sub 12} (half-metallic behavior). The numerical values of isotropic elastic parameters and related properties are estimated in the framework of the Voigt–Reuss–Hill approximation. The calculation of thermal transport properties at various temperature shows the high value of Seebeck coefficient and figure of merit (ZT) = 0.25 at room temperature in consistent to the experimental results.

  1. Evaluation of debris extruded apically during the removal of root canal filling material using ProTaper, D-RaCe, and R-Endo rotary nickel-titanium retreatment instruments and hand files.

    Science.gov (United States)

    Topçuoğlu, Hüseyin Sinan; Aktı, Ahmet; Tuncay, Öznur; Dinçer, Asiye Nur; Düzgün, Salih; Topçuoğlu, Gamze

    2014-12-01

    The aim of this study was to evaluate the amount of debris extruded apically during the removal of root canal filling material using ProTaper (Dentsply Maillefer, Ballaigues, Switzerland), D-RaCe (FKG Dentaire, La Chaux-de-Fonds, Switzerland), and R-Endo (Micro-Mega, Besançon, France) nickel-titanium (NiTi) rotary retreatment instruments and hand files. Sixty extracted single-rooted mandibular premolar teeth were prepared with K-files and filled with gutta-percha and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany). The teeth were then randomly assigned to 4 groups (n = 15 for each group) for retreatment. The removal of canal filling material was performed as follows: hand files, ProTaper, D-RaCe, and R-Endo retreatment instruments. Debris extruded apically during the removal of canal filling material was collected into preweighed Eppendorf tubes. The tubes were then stored in an incubator at 70°C for 5 days. The weight of the dry extruded debris was established by subtracting the preretreatment and postretreatment weight of the Eppendorf tubes for each group. The data obtained were analyzed using 1-way analysis of variance and Tukey post hoc tests. All retreatment techniques caused the apical extrusion of debris. Hand files produced significantly more debris when compared with ProTaper, D-RaCe, and R-Endo rotary systems (P ProTaper, D-RaCe, and R-Endo retreatment systems (P > .05). The findings showed that during the removal of root canal filling material, rotary NiTi retreatment instruments used in this study caused less apical extrusion of debris compared with hand files. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Hydrogen Filling Station

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, Robert F; Sabacky, Bruce; Anderson II, Everett B; Haberman, David; Al-Hassin, Mowafak; He, Xiaoming; Morriseau, Brian

    2010-02-24

    future. Project partners also conducted a workshop on hydrogen safety and permitting. This provided an opportunity for the various permitting agencies and end users to gather to share experiences and knowledge. As a result of this workshop, the permitting process for the hydrogen filling station on the Las Vegas Valley Water District’s land was done more efficiently and those who would be responsible for the operation were better educated on the safety and reliability of hydrogen production and storage. The lessons learned in permitting the filling station and conducting this workshop provided a basis for future hydrogen projects in the region. Continuing efforts to increase the working pressure of electrolysis and efficiency have been pursued. Research was also performed on improving the cost, efficiency and durability of Proton Exchange Membrane (PEM) hydrogen technology. Research elements focused upon PEM membranes, electrodes/catalysts, membrane-electrode assemblies, seals, bipolar plates, utilization of renewable power, reliability issues, scale, and advanced conversion topics. Additionally, direct solar-to-hydrogen conversion research to demonstrate stable and efficient photoelectrochemistry (PEC) hydrogen production systems based on a number of optional concepts was performed. Candidate PEC concepts included technical obstacles such as inefficient photocatalysis, inadequate photocurrent due to non-optimal material band gap energies, rapid electron-hole recombination, reduced hole mobility and diminished operational lifetimes of surface materials exposed to electrolytes. Project Objective 1: Design, build, operate hydrogen filling station Project Objective 2: Perform research and development for utilizing solar technologies on the hydrogen filling station and convert two utility vehicles for use by the station operators Project Objective 3: Increase capacity of hydrogen filling station; add additional vehicle; conduct safety workshop; develop a roadmap for

  3. QENS investigation of filled rubbers

    CERN Document Server

    Triolo, A; Desmedt, A; Pieper, J K; Lo Celso, F; Triolo, R; Negroni, F; Arrighi, V; Qian, H; Frick, B

    2002-01-01

    The polymer segmental dynamics is investigated in a series of silica-filled rubbers. The presence of inert fillers in polymers greatly affects the mechanical and physical performance of the final materials. For example, silica has been proposed as a reinforcing agent of elastomers in tire production. Results from quasielastic neutron scattering and Dynamic Mechanical Thermal Analysis (DMTA) measurements are presented on styrene-ran-butadiene rubber filled with silica. A clear indication is obtained of the existence of a bimodal dynamics, which can be rationalized in terms of the relaxation of bulk rubber and the much slower relaxation of the rubber adsorbed on the filler surface. (orig.)

  4. Sodium fill of FFTF

    International Nuclear Information System (INIS)

    Waldo, J.B.; Greenwell, R.K.; Keasling, T.A.; Collins, J.R.; Klos, D.B.

    1980-02-01

    With construction of the Fast Flux Test Facility (FFTF) completed, the first major objective in the startup program was to fill the sodium systems. A sodium fill sequence was developed to match construction completion, and as systems became available, they were inerted, preheated, and filled with sodium. The secondary sodium systems were filled first while dry refueling system testing was in progress in the reactor vessel. The reactor vessel and the primary loops were filled last. This paper describes the methods used and some of the key results achieved for this major FFTF objective

  5. Evaluation of Root-End Resections Performed by Er, Cr: YSGG Laser with and without Placement of a Root-End Filling Material

    Directory of Open Access Journals (Sweden)

    John Sullivan

    2009-01-01

    Full Text Available Microleakage following root-end resections has a direct influence on the outcome of surgical endodontic procedures. This study compared the microleakage after root-end resections performed by the Er, Cr: YSGG laser or carbide burs with or without the placement of MTA, and evaluated the presence of microcracks and gaps at the interface of GP/MTA and the canal walls. Ninety single-rooted teeth were instrumented, obturated with GP and AH-Plus sealer, and divided into 3 experimental groups: (I root-end resections were performed with the laser and G6 tips (parameters: 4.5 w, 30 pps, 20% water and 50% air; (II Lindeman burs were used, without the placement of MTA; (III the burs were used followed by root-end fillings with MTA, and one control (IV of five unobturated roots resected with the burs. The samples were prepared for microleakage (=20 and SEM (=10 analysis. They were immersed in 1% methylene blue, decalcified, cleared, and evaluated for dye penetration (mm2 with the ImageJ software. Epoxy-resin replicas of the root-ends were analyzed by SEM for gaps (m2 and microcracks. Microleakage results were 0.518±1.059, 0.172±0.223, and 0.158±0.253, for the laser (I, no root-end filling (II, and MTA (III samples, respectively, (ANOVA =.02. The laser (7831.7±2329.2 and no root-end filling (7137.3±1400.7 samples presented gaps. Whereas, none was found in the MTA (ANOVA =.002. Microcracks were not observed. The MTA group demonstrated statistically less leakage and better adaptation to the canal walls when compared to the other groups. There was no correlation between the size of the gaps and the degree of microleakage.

  6. 装填材料密度对侵彻膨胀弹终点效应的影响%Influence of Filling Material Density on Terminal Effect of PELE Projectile

    Institute of Scientific and Technical Information of China (English)

    尹建平; 王志军; 魏继允

    2011-01-01

    By building the model of the penetrator with enhanced lateral efficiency(PELE) and target of steel plate, LS-DYNA was used to simulate penetration of PELE filled copper, 2024-T3 aluminium and nylon against 4340 steel plate at the impact velocity of 1 500 m/s. The results show that the filling material has important influence on the producing of lateral efficiency. In a certain range, with the filling material density decreases, the lateral efficiency range becomes wider, and the remnant velocity after penetrating target becomes lesser.%在建立弹靶模型的基础上,采用有限元软件LS-DYNA分别对装填铜,2024-T3铝和尼龙的侵彻膨胀弹以1 500 m/s着靶速度侵彻4340钢靶板的过程进行了数值模拟.结果表明:装填材料对侵彻膨胀弹横向效应的产生有较大影响.一定范围内装填材料的密度越小,PELE速度变化缓慢,而且变化持续时间越长,穿透靶板后的残余速度越小,产生横向效应的区域越大.

  7. Elaboration of protocol for characterization of clay as a filling material and coverage for surface repository; Elaboracao de protocolo para caracterizacao de argilas como material de recheio e de cobertura para repositorio de superficie

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Daisy Mary Marchezini dos

    2017-04-01

    The nuclear energy in its various applications generates wastes that must be properly treated. The Radioactive Waste Management covers operations since generation of the waste until to its storage in repository ensuring the protection of man and of environment of the possible negative impacts. The radioactive waste are segregated, treated, conditioned in suitable packaging and posteriorly are stored or disposal in repository. The “RBMN Project” is a priority project of CNEN to implementation the repository for the deposition of low and intermediate level radioactive waste generated by nuclear energy activities in Brazil, proposing a definitive solution for its storage. Engineered and natural barriers as the filling layer and coverage layer will compose the disposal system of a near surface repository, concept proposed by the “RBMN Project”. The use these barriers views to avoid or restrict the release of radionuclides present in waste for the humans beings and environment. The waterproofing barriers are composed of clays. Certainly, for the national repository, will be used those clays existing in the place where it will be implanted it. So some fundamentals tests will have to be carried for to verify the suitability of these clays as barriers. These tests were determined and realized with a reference clay, a brazilian bentonite constituted of 67.2% montmorillonite. The results were compared with national and international literature of materials with similar mineralogical features. The values found with 95% reliance were 9.73±0,35 μm for granulometric size. For the moisture content were 13,3±0,6% and for capacity of cationic exchange were , 816±9 mmol.kg{sup -1}. For the hydraulic conductivity, without the use of internal pressure, it was obtained maximum value of 59.0% saturated. In addition, during the observed period, there was no percolation in the test specimen submitted to internal pressure of 200 kPa. This result leads to the conclusion that the

  8. Iron filled carbon nanostructures from different precursors

    International Nuclear Information System (INIS)

    Costa, S.; Borowiak-Palen, E.; Bachmatiuk, A.; Ruemmeli, M.H.; Gemming, T.; Kalenczuk, R.J.

    2008-01-01

    Here, we present a study on the synthesis of different nanostructures with one single-step in situ filling (encapsulation) via carbon vapor deposition (CVD). Ferrocene, acetylferrocene and iron (II) nitrate as iron precursors were explored. The application of each of these compounds resulted in different carbon nanomaterials such as: iron filled multiwalled carbon nanotubes with a low filling ratio (Fe-MWCNT), iron filled nanocapsules and unfilled MWCNT. The as-produced samples were purified by high temperature annealing and acid treatment. The purified materials were characterised using transmission electron microscopy (TEM) and Raman spectroscopy

  9. Computerized simulation of the mechanical behavior of wood-filled shock absorbers of radioactive materials transport casks; Rechnerische Simulation des mechanischen Verhaltens von holzgefuellten Stossdaempfern von Transportbehaeltern fuer radioaktive Stoffe

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, Martin; Wille, Frank [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany)

    2011-07-01

    In Germany the mechanical component inspection of transport containers for radioactive materials is performed by BAM (Bundesanstalt fuer Materialforschung und -pruefung) under consideration of national and international standards and guidelines. Experimental and calculative (analytical and numerical) techniques combined with material and/or component testing are the basis of assessment concepts according the state of the art. The authors describe the experiences of BAM concerning assessment and description of the mechanical behavior of shock absorbing components, including modeling strategies, material models, drop tests and experiment-calculation comparison. Energy absorbing components are used to reduce the impact forces at the container in case of a transport accident. In Germany wood filled thin-walled constructions are used. The deformation behavior of the wood is a main part of the calculative simulation procedures in comparison with experimental tests.

  10. Operation feedback of hydrogen filling station

    International Nuclear Information System (INIS)

    Pregassame, S.; Barral, K.; Allidieres, L.; Charbonneau, T.; Lacombe, Y.

    2004-01-01

    One of the technical challenges of hydrogen technology is the development of hydrogen infrastructures which satisfy either safety requirements and reliability of filling processes. AIR LIQUIDE realized an hydrogen filling station in Sassenage (France) operational since September 2003. This station is able to fill 3 buses a day up to 350bar by equilibrium with high pressure buffers. In parallel with commercial stations, the group wanted to create a testing ground in real conditions running with several objectives: validate on a full scale bench a simulation tool able to predict the temperature of both gas and cylinder's materials during filling processes; define the best filling procedures in order to reach mass, temperature and filling time targets; analyse the temperature distribution and evolution inside the cylinder; get a general knowledge about hydrogen stations from safety and reliability point of view; operate the first full scale refuelling station in France. The station is also up-graded for 700bar filling from either a liquid hydrogen source or a gas booster, with cold filling possibility. This paper presents the results concerning 350bar filling : thermal effects, optimal filling procedures and influence of parameters such as climatic conditions are discussed. (author)

  11. Sealing ability of white and gray mineral trioxide aggregate mixed with distilled water and 0.12% chlorhexidine gluconate as a root end filling material: An ex vivo evaluation

    Directory of Open Access Journals (Sweden)

    Sreegowri

    2013-01-01

    Full Text Available Aim: The aim of this study was to evaluate the sealing ability of white and gray mineral trioxide aggregate (MTA mixed with distilled water and 0.12% chlorhexidine (CHX gluconate when used as a root-end filling material using the dye-penetration technique. Materials and Methods: A total of 48 single-rooted human teeth were cleaned, shaped, and obturated with gutta-percha and AH Plus sealer. The apical 3 mm of each root was resected, and 3-mm deep root-end cavity preparations were made. The teeth were randomly divided into 4 experimental groups, each containing 8 teeth, and 2 negative and positive control groups, each containing 8 teeth. Root-end cavities in the experimental groups were filled with the experimental materials. After application of nail polish, the teeth were exposed to India ink for 72 h and longitudinally sectioned, and the extent of dye penetration was measured with a stereomicroscope. Results : No statistically significant differences were observed in the sealing ability of gray and white MTA mixed with distilled water and 0.12% CHX. Conclusion : CHX appears to be a good alternative to replace distilled water, as a solution to be mixed with MTA.

  12. Effects of Ceramic Density and Sintering Temperature on the Mechanical Properties of a Novel Polymer-Infiltrated Ceramic-Network Zirconia Dental Restorative (Filling) Material.

    Science.gov (United States)

    Li, Weiyan; Sun, Jian

    2018-05-10

    BACKGROUND Polymer-infiltrated ceramic-network (PICN) dental material is a new and practical development in orthodontics. Sintering is the process of forming a stable solid mass from a powder by heating without melting. The aim of this study was to evaluate the effects of sintering temperature on the mechanical properties of a PICN zirconia dental material. MATERIAL AND METHODS A dense zirconia ceramic and four PICN zirconia dental materials, with varying porosities, were sintered at three different temperatures; 12 PICN zirconia dental materials based on these porous ceramics were prepared, as well as a pure polymer. After the specimen preparation, flexural strength and elastic modulus values were measured using the three-point bending test, and fracture toughness were determined by the single-edge notched beam (SENB) method. The Vickers hardness test method was used with an indentation strength (IS) test. Scanning electron microscopy (SEM) was used to examine the microstructure of the ceramic surface and the fracture surface. RESULTS Mechanical properties of the PICN dental materials, including flexural strength, elastic modulus, fracture toughness, and hardness, were more similar to the properties of natural teeth when compared with traditional dental ceramic materials, and were affected by the density and sintering temperature. SEM showed that the porous ceramic network became cohesive and that the length of cracks in the PICN dental material was reduced. CONCLUSIONS PICN zirconia dental materials were characterized by similar mechanical properties to natural dental tissues, but further studies are required continue to improve the similarities with natural human enamel and dentin.

  13. Filter to be tightly installed in a room as a partition and which can be filled with a contact material susceptible of being poured e.g. activated charcoal for cleaning especially radioactive air or gases in nuclear installations

    International Nuclear Information System (INIS)

    Neumann, G.M.

    1978-01-01

    The filter is designed in such manner that it will resist all loads - including earthquake - without loosing its operability. It consists of a box formed by stable corner irons filled with absorbing material and bounded on two sides by sieves through which the radioactive gases can flow in and out. The invention especially concerns the configuration of the perforations and the screwing of the casing elements to the frame as well as the arrangement in the concrete wall. Measures for fire fighting are also provided for. (UWI) [de

  14. New recycling approaches for thermoset polymeric composite wastes – an experimental study on polyester based concrete materials filled with fibre reinforced plastic recyclates

    OpenAIRE

    Ribeiro, M. C. S.; Fiúza, António; Meira Castro, A C; Dinis, M. L.; Silva, Francisco J. G.; Meixedo, João Paulo

    2011-01-01

    In this study, a new waste management solution for thermoset glass fibre reinforced polymer (GFRP) based products was assessed. Mechanical recycling approach, with reduction of GFRP waste to powdered and fibrous materials was applied, and the prospective added-value of obtained recyclates was experimentally investigated as raw material for polyester based mortars. Different GFRP waste admixed mortar formulations were analyzed varying the content, between 4% up to 12% in we...

  15. Filling a Conical Cavity

    Science.gov (United States)

    Nye, Kyle; Eslam-Panah, Azar

    2016-11-01

    Root canal treatment involves the removal of infected tissue inside the tooth's canal system and filling the space with a dense sealing agent to prevent further infection. A good root canal treatment happens when the canals are filled homogeneously and tightly down to the root apex. Such a tooth is able to provide valuable service for an entire lifetime. However, there are some examples of poorly performed root canals where the anterior and posterior routes are not filled completely. Small packets of air can be trapped in narrow access cavities when restoring with resin composites. Such teeth can cause trouble even after many years and lead the conditions like acute bone infection or abscesses. In this study, the filling of dead-end conical cavities with various liquids is reported. The first case studies included conical cavity models with different angles and lengths to visualize the filling process. In this investigation, the rate and completeness at which a variety of liquids fill the cavity were observed to find ideal conditions for the process. Then, a 3D printed model of the scaled representation of a molar with prepared post spaces was used to simulate the root canal treatment. The results of this study can be used to gain a better understanding of the restoration for endodontically treated teeth.

  16. Raman spectra of filled carbon nanotubes

    International Nuclear Information System (INIS)

    Bose, S.M.; Behera, S.N.; Sarangi, S.N.; Entel, P.

    2004-01-01

    The Raman spectra of a metallic carbon nanotube filled with atoms or molecules have been investigated theoretically. It is found that there will be a three way splitting of the main Raman lines due to the interaction of the nanotube phonon with the collective excitations (plasmons) of the conduction electrons of the nanotube as well as its coupling with the phonon of the filling material. The positions and relative strengths of these Raman peaks depend on the strength of the electron-phonon interaction, phonon frequency of the filling atom and the strength of interaction of the nanotube phonon and the phonon of the filling atoms. Careful experimental studies of the Raman spectra of filled nanotubes should show these three peaks. It is also shown that in a semiconducting nanotube the Raman line will split into two and should be observed experimentally

  17. Conductive materials for proton exchange membrane fuel cell bipolar plates made from PVDF, PET and co-continuous PVDF/PET filled with carbon additives

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, L.; Mighri, F.; Deyrail, Y. [CREPEC, Center for Applied Research on Polymers and Composites, QC (Canada); Department of Chemical Engineering, Laval University, QC (Canada); Elkoun, S. [CREPEC, Center for Applied Research on Polymers and Composites, QC (Canada); Department of Mechanical Engineering, Sherbrooke University, QC (Canada)

    2010-12-15

    The aim of this work was to develop and characterise electrically conductive materials for proton exchange membrane fuel cells and bipolar plates (BPPs). These BPPs were made from highly conductive blends of polyethylene terephthalate (PET) and polyvinylidene fluoride (PVDF), as matrix phase. The conductive materials were developed from carefully formulated blends composed of conductive carbon black (CB) powder and, in some cases, graphite synthetic flakes mixed with pure PET, PVDF or with PVDF/PET systems. They were first developed by twin-screw extrusion process then compression-molded to give BPP final shape. As the developed blends have to meet properties suitable for BPP applications, they were characterised for their rheological properties, electrical through-plane resistivity (the inverse of conductivity), oxygen permeability, flexural and impact properties. Results showed that lower resistivity was obtained with PVDF/CB blends due to the higher interfacial energy between the PVDF matrix and CB and also the higher density and crystallinity of PVDF, compared to those of PET. It was also observed that the lowest resistivity values were obtained with mixing PVDF and PET at controlled compositions to ensure PVDF/PET co-continuous morphology. Also, slow cooling rates helped to attain the lowest values of through-plane resistivity for all studied blends. This behaviour was related to the higher crystallinity obtained with low cooling rates leading to smaller amorphous regions in which carbon particles are much more concentrated. (Copyright copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. 21 CFR 872.3820 - Root canal filling resin.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Root canal filling resin. 872.3820 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3820 Root canal filling resin. (a) Identification. A root canal filling resin is a device composed of material, such as methylmethacrylate, intended...

  19. Creep of granulated loose-fill insulation

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    This report presents a proposal for a standardised method for creep tests and the necessary theoretical framework that can be used to describe creep of a granulated loose-fill material. Furthermore results from a round robin test are shown. The round robin test was carried out in collaboration...... with SP-Building Physics in Sweden and VTT Building Technology in Finland. For the round robin test a cellulosic fibre insulation material was used. The proposed standardised method for creep tests and theories are limited to cases when the granulated loose-fill material is exposed to a constant...

  20. Analysis of the heat transfer mechanisms during energy storage in a Phase Change Material filled vertical finned cylindrical unit for free cooling application

    International Nuclear Information System (INIS)

    Solomon, Gnanadurai Ravikumar; Velraj, Ramalingam

    2013-01-01

    Highlights: • Freezing behavior of a PCM, in a cylinder with annular longitudinal fins is presented. • Among various fin heights, 20 mm fin contribute maximum heat transfer enhancement. • Addition of fins plays a contradictory role during the sensible cooling of liquid PCM. • The fin effect along with external cooling, vary the sensible cooling rate of liquid PCM. • The surface convective resistance dominated over the conductive resistance of PCM. - Abstract: The heat transfer performance of the Phase Change Material (PCM) used in free cooling application is low due to poor thermal conductivity. The addition of fins to enhance the heat transfer during solidification process is commonly employed, to address this. However for application such as free cooling, where the driving temperature potential is very less, the present experimental study is intended to investigate the sensible and subcooling phenomena during the outward cylindrical solidification of the PCM stored on the annulus side, along with 8 longitudinal uniformly spaced copper fins of different heights. The performance of the fins during solidification is analyzed, and the best suitable height is arrived at. The addition of fins plays a contradicting role during the sensible cooling of the liquid PCM, due to the suppression of free convection. The external cooling conditions along with the effect of the fin, vary the sensible cooling rate of the liquid PCM, that influences the subcooling effect, and also drifts the temperature at which major phase change occurs. In addition, the effects due to the inlet velocity of the heat transfer fluid, and its temperature on heat transfer are investigated and reported. The increase in velocity decreases the duration of solidification, and this effect is more pronounced towards the entry region, due to the higher local convective heat transfer co-efficient and a comparatively higher driving temperature potential

  1. Relleno de cavidades óseas en cirugía maxilofacial con materiales aloplásticos Bone cavity filling with alloplastic material in maxillofacial surgery

    Directory of Open Access Journals (Sweden)

    S. Ochandiano Caicoya

    2007-02-01

    Full Text Available En los estudios de regeneración ósea se distinguen dos tipos de defectos, los que carecen de capacidad de regeneración espontánea durante toda la vida del individuo (defectos de tamaño crítico y los que sí que poseen dicha capacidad (de tamaño no crítico, siempre que aportemos las condiciones adecuadas, estabilización del coágulo, mantenimiento del espacio y reposo mecánico (concepto de regeneración ósea guiada. En esta controversia revisamos el defecto óseo del seno maxilar y las cavidades residuales postquistectomía, ambos defectos de tamaño no crítico que conservan varias de sus paredes. En la elevación de seno muchos autores concluían que era necesario aportar siempre hueso autólogo en el material de injerto, bien en solitario o en distintas mezclas con biomateriales en proporciones no definidas, 50:50, 20:80 etc. La evidencia clínica y la que recoge la literatura en los últimos años contradice esa conclusión y ya se afirma que los biomateriales en exclusiva en el seno maxilar consiguen resultados equiparables al hueso autólogo siempre que se aumente el periodo de osificación. Repasamos nuevos estudios que incluso discuten la necesidad de utilizar ningún tipo de injerto para conseguir neoformación ósea dentro del seno maxilar. Los resultados en el defecto óseo de cavidades residuales postquistectomía, en las que consigamos mantener varias de sus paredes, son todavía más concluyentes. El mejor tratamiento de esos defectos es el cierre directo de la mucosa y esperar a la regeneración espontánea del defecto. La utilización de hueso autólogo es innecesaria y si aportamos biomateriales tampoco conseguimos un mejor comportamiento biomecánico del hueso residual, retrasamos la osificación y aumentamos el número de complicaciones. Sólo los defectos de espesor total pueden beneficiarse de la utilización de membranas. Los defectos que han perdido varias paredes pueden perder su capacidad de regeneración

  2. Tension-filled Governance?

    DEFF Research Database (Denmark)

    Celik, Tim Holst

    on the statesituated tension-filled functional relationship between legitimation and accumulation, the study both historically and theoretically reworks this approach and reapplies it for the post-1970s/1990s governance period. It asks whether and to what extent governance has served as a distinctive post- 1970s/1990s...

  3. filled neutron detectors

    Indian Academy of Sciences (India)

    Boron trifluoride (BF3) proportional counters are used as detectors for thermal neutrons. They are characterized by high neutron sensitivity and good gamma discriminating properties. Most practical BF3 counters are filled with pure boron trifluoride gas enriched up to 96% 10B. But BF3 is not an ideal proportional counter ...

  4. Gas filled detectors

    International Nuclear Information System (INIS)

    Stephan, C.

    1993-01-01

    The main types of gas filled nuclear detectors: ionization chambers, proportional counters, parallel-plate avalanche counters (PPAC) and microstrip detectors are described. New devices are shown. A description of the processes involved in such detectors is also given. (K.A.) 123 refs.; 25 figs.; 3 tabs

  5. [Legal and medico-legal issues in adolescent medicine. A critical review of the present regulation and legislation].

    Science.gov (United States)

    Schwarzenberg, T L; Buffone, M R

    2001-02-01

    During the last years the Italian Government has taken many different initiatives to protect the adolescents rights to benefit from physical, psychical and social well-being. In particular, various projects concerning the promotion and the support of the school, the family, sport, mass-media, judicial and medical infrastructures, have been organised, promoted and financed. However, it is not always possible to assure a real safeguarding of teenagers rights; this especially happens because the problem concerning the autonomous capacity of minors to consent (or non consent) to the medical treatment is much debated. However, many contradictions still persist about the effective duration of the pediatric age. All the same, it must be noted that the Legislator apparently realised that not only the physical, psychological and social maturity proceed by steps, but also the legal capacity.

  6. Pregnancy-associated Death - Clarifying the Cause of Death and Medico-legal Assessments in Accusations of Malpractice.

    Science.gov (United States)

    Dettmeyer, Reinhard; Lang, Juliane; Amberg, Rainer; Zedler, Barbara; Schulz, Ronald; Birngruber, Christoph

    2018-02-01

    Pregnancy-associated deaths are extremely rare in Germany. Most deaths are from natural causes, and a range of causes are possible. The deaths of 22 women who died of pregnancy-associated causes and who were autopsied in the Institute of Forensic Medicine of Justus-Liebig University Gießen between 1992 and 2016 were analyzed. The autopsy results and histological examinations for the majority of women who died of pregnancy-associated causes between 1992 and 2016 showed that they had died of natural causes, although complications of pregnancy were a leading cause of death. The death of a pregnant woman should not automatically raise the suspicion of malpractice, although the question does arise in cases of bleeding complications only detected at very late stages. Experts must prove that a real mistake was made during treatment and provide evidence of the causality between malpractice and patient death. Particularly when well-known complications of pregnancy were present, this is only the case if poor monitoring resulted in the complication being detected too late or if treatment was not in accordance with accepted standards of care. The majority of pregnancy-associated deaths are from natural causes and the death of a pregnant woman does not mean that medical malpractice was involved, although this accusation is often levelled in cases where rupture was not immediately diagnosed or in cases of fatal postpartum hemorrhage.

  7. Necrotizing fasciitis: case series and review of the literature on clinical and medico-legal diagnostic challenges.

    Science.gov (United States)

    Fais, Paolo; Viero, Alessia; Viel, Guido; Giordano, Renzo; Raniero, Dario; Kusstatscher, Stefano; Giraudo, Chiara; Cecchetto, Giovanni; Montisci, Massimo

    2018-04-07

    Necrotizing fasciitis (NF) is a life-threatening infection of soft tissues spreading along the fasciae to the surrounding musculature, subcutaneous fat and overlying skin areas that can rapidly lead to septic shock and death. Due to the pandemic increase of medical malpractice lawsuits, above all in Western countries, the forensic pathologist is frequently asked to investigate post-mortem cases of NF in order to determine the cause of death and to identify any related negligence and/or medical error. Herein, we review the medical literature dealing with cases of NF in a post-mortem setting, present a case series of seven NF fatalities and discuss the main ante-mortem and post-mortem diagnostic challenges of both clinical and forensic interests. In particular, we address the following issues: (1) origin of soft tissue infections, (2) micro-organisms involved, (3) time of progression of the infection to NF, (4) clinical and histological staging of NF and (5) pros and cons of clinical and laboratory scores, specific forensic issues related to the reconstruction of the ideal medical conduct and the evaluation of the causal value/link of any eventual medical error.

  8. Medico legal aspects of self-injection of metallic mercury in cases of suicide or self-harming.

    Science.gov (United States)

    Da Broi, Ugo; Moreschi, Carlo; Colatutto, Antonio; Marcon, Barbara; Zago, Silvia

    2017-08-01

    Metallic mercury may be self-injected for suicidal or self-harm purposes or sometimes for superstitious or other inadvisable reasons. Local tissue or systemic consequences such as mercurialism can frequently occur in cases of subcutaneous or deep injection, while death due to pulmonary embolism and cardiac, brain, hepatic or renal toxicity may occur in cases of high dosage intravenous administration. The aim of this review is to focus on the diagnostic difficulties facing coroners and forensic pathologists when the courts require confirmation that evidence of self-injection of metallic mercury is the result of suicide or self-harming. Forensic examination performed on the corpses of victims who died in or out of hospital or on surviving injured or intoxicated victims showing signs of mercurialism, demands the careful evaluation of the death scene, of all related circumstances and of the clinical and autopsy data. Close interaction between forensic pathologists and toxicologists is also needed to identify and quantify mercury levels in blood, urine and tissue. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  9. Medico-legal significance of service difficulties and clinical errors in the management of patients with inflammatory bowel diseases.

    Science.gov (United States)

    Farrukh, Affifa; Mayberry, John F

    2015-03-01

    There is a significant growth in medical litigation, and cases involving the care and management of patients with inflammatory bowel disease are becoming common. There is no central register of such cases, and the majority are settled before court proceedings. As a result, there is no specific case law related to such conditions, and secrecy usually surrounds the outcome with "no admission of guilt" by the defendant and a clause about non-disclosure and discussion linked to the financial compensation received by the claimant. This review discusses common areas of potential litigation. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  10. Bio-inspired dental fillings

    Science.gov (United States)

    Deyhle, Hans; Bunk, Oliver; Buser, Stefan; Krastl, Gabriel; Zitzmann, Nicola U.; Ilgenstein, Bernd; Beckmann, Felix; Pfeiffer, Franz; Weiger, Roland; Müller, Bert

    2009-08-01

    Human teeth are anisotropic composites. Dentin as the core material of the tooth consists of nanometer-sized calcium phosphate crystallites embedded in collagen fiber networks. It shows its anisotropy on the micrometer scale by its well-oriented microtubules. The detailed three-dimensional nanostructure of the hard tissues namely dentin and enamel, however, is not understood, although numerous studies on the anisotropic mechanical properties have been performed and evaluated to explain the tooth function including the enamel-dentin junction acting as effective crack barrier. Small angle X-ray scattering (SAXS) with a spatial resolution in the 10 μm range allows determining the size and orientation of the constituents on the nanometer scale with reasonable precision. So far, only some dental materials, i.e. the fiber reinforced posts exhibit anisotropic properties related to the micrometer-size glass fibers. Dental fillings, composed of nanostructures oriented similar to the natural hard tissues of teeth, however, do not exist at all. The current X-ray-based investigations of extracted human teeth provide evidence for oriented micro- and nanostructures in dentin and enamel. These fundamental quantitative findings result in profound knowledge to develop biologically inspired dental fillings with superior resistance to thermal and mechanical shocks.

  11. Systolic ventricular filling.

    Science.gov (United States)

    Torrent-Guasp, Francisco; Kocica, Mladen J; Corno, Antonio; Komeda, Masashi; Cox, James; Flotats, A; Ballester-Rodes, Manel; Carreras-Costa, Francesc

    2004-03-01

    The evidence of the ventricular myocardial band (VMB) has revealed unavoidable coherence and mutual coupling of form and function in the ventricular myocardium, making it possible to understand the principles governing electrical, mechanical and energetical events within the human heart. From the earliest Erasistratus' observations, principal mechanisms responsible for the ventricular filling have still remained obscured. Contemporary experimental and clinical investigations unequivocally support the attitude that only powerful suction force, developed by the normal ventricles, would be able to produce an efficient filling of the ventricular cavities. The true origin and the precise time frame for generating such force are still controversial. Elastic recoil and muscular contraction were the most commonly mentioned, but yet, still not clearly explained mechanisms involved in the ventricular suction. Classical concepts about timing of successive mechanical events during the cardiac cycle, also do not offer understandable insight into the mechanism of the ventricular filling. The net result is the current state of insufficient knowledge of systolic and particularly diastolic function of normal and diseased heart. Here we summarize experimental evidence and theoretical backgrounds, which could be useful in understanding the phenomenon of the ventricular filling. Anatomy of the VMB, and recent proofs for its segmental electrical and mechanical activation, undoubtedly indicates that ventricular filling is the consequence of an active muscular contraction. Contraction of the ascendent segment of the VMB, with simultaneous shortening and rectifying of its fibers, produces the paradoxical increase of the ventricular volume and lengthening of its long axis. Specific spatial arrangement of the ascendent segment fibers, their interaction with adjacent descendent segment fibers, elastic elements and intra-cavitary blood volume (hemoskeleton), explain the physical principles

  12. Dye filled security seal

    International Nuclear Information System (INIS)

    Wilson, D.C.

    1982-01-01

    A security seal for providing an indication of unauthorized access to a sealed object includes an elongate member to be entwined in the object such that access is denied unless the member is removed. The elongate member has a hollow, pressurizable chamber extending throughout its length that is filled with a permanent dye under greater than atmospheric pressure. Attempts to cut the member and weld it together are revealed when dye flows through a rupture in the chamber wall and stains the outside surface of the member

  13. Benign gastric filling defect

    International Nuclear Information System (INIS)

    Oh, K. K.; Lee, Y. H.; Cho, O. K.; Park, C. Y.

    1979-01-01

    The gastric lesion is a common source of complaints to Orientals, however, evaluation of gastric symptoms and laboratory examination offer little specific aid in the diagnosis of gastric diseases. Thus roentgenography of gastrointestinal tract is one of the most reliable method for detail diagnosis. On double contract study of stomach, gastric filling defect is mostly caused by malignant gastric cancer, however, other benign lesions can cause similar pictures which can be successfully treated by surgery. 66 cases of benign causes of gastric filling defect were analyzed at this point of view, which was verified pathologically by endoscope or surgery during recent 7 years in Yensei University College of Medicine, Severance Hospital. The characteristic radiological picture of each disease was discussed for precise radiologic diagnosis. 1. Of total 66 cases, there were 52 cases of benign gastric tumor 10 cases of gastric varices, 5 cases of gastric bezoar, 5 cases of corrosive gastritis, 3 cases of granulomatous disease and one case of gastric hematoma. 2. The most frequent causes of benign tumors were adenomatous polyp (35/42) and the next was leiomyoma (4/42). Others were one of case of carcinoid, neurofibroma and cyst. 3. Characteristic of benign adenomatous polyp were relatively small in size, smooth surface and were observed that large size, benign polyp was frequently type IV lesion with a stalk. 4. Submucosal tumors such as leiomyoma needed differential diagnosis with polypoid malignant cancer. However, the characteristic points of differentiation was well circumscribed smooth margined filling defect without definite mucosal destruction on surface. 5. Gastric varices showed multiple lobulated filling defected especially on gastric fundus that changed its size and shape by respiration and posture of patients. Same varices lesions on esophagus and history of liver disease were helpful for easier diagnosis. 6. Gastric bezoar showed well defined movable mass

  14. Benign gastric filling defect

    Energy Technology Data Exchange (ETDEWEB)

    Oh, K. K.; Lee, Y. H.; Cho, O. K.; Park, C. Y. [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1979-06-15

    The gastric lesion is a common source of complaints to Orientals, however, evaluation of gastric symptoms and laboratory examination offer little specific aid in the diagnosis of gastric diseases. Thus roentgenography of gastrointestinal tract is one of the most reliable method for detail diagnosis. On double contract study of stomach, gastric filling defect is mostly caused by malignant gastric cancer, however, other benign lesions can cause similar pictures which can be successfully treated by surgery. 66 cases of benign causes of gastric filling defect were analyzed at this point of view, which was verified pathologically by endoscope or surgery during recent 7 years in Yensei University College of Medicine, Severance Hospital. The characteristic radiological picture of each disease was discussed for precise radiologic diagnosis. 1. Of total 66 cases, there were 52 cases of benign gastric tumor 10 cases of gastric varices, 5 cases of gastric bezoar, 5 cases of corrosive gastritis, 3 cases of granulomatous disease and one case of gastric hematoma. 2. The most frequent causes of benign tumors were adenomatous polyp (35/42) and the next was leiomyoma (4/42). Others were one of case of carcinoid, neurofibroma and cyst. 3. Characteristic of benign adenomatous polyp were relatively small in size, smooth surface and were observed that large size, benign polyp was frequently type IV lesion with a stalk. 4. Submucosal tumors such as leiomyoma needed differential diagnosis with polypoid malignant cancer. However, the characteristic points of differentiation was well circumscribed smooth margined filling defect without definite mucosal destruction on surface. 5. Gastric varices showed multiple lobulated filling defected especially on gastric fundus that changed its size and shape by respiration and posture of patients. Same varices lesions on esophagus and history of liver disease were helpful for easier diagnosis. 6. Gastric bezoar showed well defined movable mass

  15. Benign gastric filling defect

    Energy Technology Data Exchange (ETDEWEB)

    Oh, K K; Lee, Y H; Cho, O K; Park, C Y [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1979-06-15

    The gastric lesion is a common source of complaints to Orientals, however, evaluation of gastric symptoms and laboratory examination offer little specific aid in the diagnosis of gastric diseases. Thus roentgenography of gastrointestinal tract is one of the most reliable method for detail diagnosis. On double contract study of stomach, gastric filling defect is mostly caused by malignant gastric cancer, however, other benign lesions can cause similar pictures which can be successfully treated by surgery. 66 cases of benign causes of gastric filling defect were analyzed at this point of view, which was verified pathologically by endoscope or surgery during recent 7 years in Yensei University College of Medicine, Severance Hospital. The characteristic radiological picture of each disease was discussed for precise radiologic diagnosis. 1. Of total 66 cases, there were 52 cases of benign gastric tumor 10 cases of gastric varices, 5 cases of gastric bezoar, 5 cases of corrosive gastritis, 3 cases of granulomatous disease and one case of gastric hematoma. 2. The most frequent causes of benign tumors were adenomatous polyp (35/42) and the next was leiomyoma (4/42). Others were one of case of carcinoid, neurofibroma and cyst. 3. Characteristic of benign adenomatous polyp were relatively small in size, smooth surface and were observed that large size, benign polyp was frequently type IV lesion with a stalk. 4. Submucosal tumors such as leiomyoma needed differential diagnosis with polypoid malignant cancer. However, the characteristic points of differentiation was well circumscribed smooth margined filling defect without definite mucosal destruction on surface. 5. Gastric varices showed multiple lobulated filling defected especially on gastric fundus that changed its size and shape by respiration and posture of patients. Same varices lesions on esophagus and history of liver disease were helpful for easier diagnosis. 6. Gastric bezoar showed well defined movable mass

  16. The utilization of coal mining wastes as filling materials in reinforced earth structures. III. Construction of a full scale experimental structure; Utilizacion de los esteriles del carbon como material de relleno en estructuras de tierra reforzada. II. Construccion de una estructura experimental

    Energy Technology Data Exchange (ETDEWEB)

    CaNibano Gonzalez, J.; Martinez, C.; Gonzalez, M.R. [HUNOSA. Programa Desarrollo Esteriles. Oviedo (Spain); Pardo, F.; SopeNa, L. [CEDEX. Laboratorio Geotecnia, Madrid (Spain); Torres, M. [Escuela Tecnica Superior de Ingenieros de Minas, Oviedo (Spain); Perez, J.J. [MOPTMA. Demarcacion Carreteras del Estado, Oviedo (Spain)

    1997-06-01

    This article describes the construction of a full scale experimental structure in which coal mining wastes (mine stones) were utilized as a filling material. In such structure, which was 20 m long and 2 high coal mining wastes from two different tips were tested together with different types of reinforcing frames such as metal bands, geomeshes and Paraweb (Freyssisol) bands. Also, thermocouples were placed at different heights. On the other hand, the said structure was subjected to 3.085 passes of a truck having a ballast of 10.5 tons on its rear axle. The performance of the coal mining wastes was completely satisfactory. (Author) 3 refs.

  17. Initial settlements of rock fills on soft clay

    OpenAIRE

    Pedersen, Truls Martens

    2012-01-01

    Rock fills that hit the seabed will remold the underlying material. If this material is a clay with sufficiently low shear strength, it will adopt rheological properties, causing flow through the rock fill, and contributing to the initial settlements of the rock fill in addition to conventional consolidation theory. The settlements of the rocks depend upon the height of the rock fill and how the rocks have been laid out. This is due to the viscosity of the clay, and the fact that clay is thix...

  18. Root canal filling using Resilon: a review.

    LENUS (Irish Health Repository)

    Shanahan, D J

    2011-07-01

    Root canal treatment is achieved by chemo-mechanical debridement of the root canal system followed by filling. The filling material \\'entombs\\' residual bacteria and acts as a barrier which prevents the entrance of oral microorganisms and reinfection of the root canal system through microleakage. However, filling with contemporary root filling materials such as gutta-percha offers limited long-term resistance to microorganisms; as a result other materials such as Resilon have been investigated as alternatives. The aim of this review was to analyse the literature to consider whether Resilon is a suitable root canal filling material. A MEDLINE and Cochrane library search including various keyword searches identified several papers which investigated or discussed Resilon or RealSeal\\/Epiphany. Analysis of the literature demonstrated that the bulk of the literature is in vitro in nature, based largely on leakage-type studies, and demonstrates a wide variety of methodologies with conflicting findings; as a result meaningful conclusions are difficult. Within the limit of these in vitro studies Resilon appears to perform adequately in comparison to gutta-percha, however, as a result of the questionable merit of such studies, it cannot presently be considered an evidence-based alternative to the current gold standard gutta-percha. It is imperative that before Resilon is considered as a replacement material, a better understanding of the physical properties of the resin sealer and the reality of the adhesive \\'monoblock\\' are elucidated. The literature also demonstrates a paucity of quality long-term clinical outcome studies which will need to be addressed before firm conclusions can be reached.

  19. Preparing for faster filling

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Following the programmed technical stop last week, operators focussed on preparing the machine for faster filling, which includes multibunch injection and a faster pre-cycle phase.   The LHC1 screen shot during the first multibunch injection operation. The LHC operational schedule incorporates a technical stop for preventive maintenance roughly every six weeks of stable operation, during which several interventions on the various machines are carried out. Last week these included the replacement of a faulty magnet in the SPS pre-accelerator, which required the subsequent re-setting of the system of particle extraction and transfer to the LHC. At the end of last week, all the machines were handed back for operation and work could start on accommodating all the changes made into the complex systems in order for normal operation to be resumed. These ‘recovery’ operations continued through the weekend and into this week. At the beginning of this week, operators succeeded in pro...

  20. Alkaline earth filled nickel skutterudite antimonide thermoelectrics

    Science.gov (United States)

    Singh, David Joseph

    2013-07-16

    A thermoelectric material including a body centered cubic filled skutterudite having the formula A.sub.xFe.sub.yNi.sub.zSb.sub.12, where A is an alkaline earth element, x is no more than approximately 1.0, and the sum of y and z is approximately equal to 4.0. The alkaline earth element includes guest atoms selected from the group consisting of Be, Mb, Ca, Sr, Ba, Ra and combinations thereof. The filled skutterudite is shown to have properties suitable for a wide variety of thermoelectric applications.

  1. Curing characteristics of flowable and sculptable bulk-fill composites

    OpenAIRE

    Miletic, Vesna; Pongpruenska, Pong; De Munck, Jan; Brooks, Neil R; Van Meerbeek, Bart

    2016-01-01

    OBJECTIVES: The aim of this study was to determine and correlate the degree of conversion (DC) with Vickers hardness (VH) and translucency parameter (TP) with the depth of cure (DoC) of five bulk-fill composites. MATERIALS AND METHODS: Six specimens per group, consisting of Tetric EvoCeram Bulk Fill ("TEC Bulk," Ivoclar Vivadent), SonicFill (Kerr), SDR Smart Dentin Replacement ("SDR," Dentsply), Xenius base ("Xenius," StickTech; commercialized as EverX Posterior, GC), Filtek Bul...

  2. Fissure fillings from Finnsjoen and Studsvik Sweden

    International Nuclear Information System (INIS)

    Tullborg, E.-L.; Larsson, S.Aa.

    1982-12-01

    Samples were taken from cores and collected at different levels. The bedrock at Finnsjoen is a Svecokarelian granite-granodiorite, the most frequent mineral in the fissures being calcite. The water from boreholes have a mean S 18 O value of -12 per thousand and saturated by calcite. Isotopically three different groups of calcite have been distinguished. Ages of 29+-13x10 3 years to 79+-25x10 3 years were estimated. Two generations of quartz were recognized the minerals prehnite and lanmontite were found Most fissure filling materials have cation exchange capacities. The bedrock at Studsvik is a Svecokarelian gneiss of sedimentary type which is migmatized with calcite and chlorite as fissure filling minerals. Most fissure fillings are thin and simple Claby minerals of smectite type are also frequent. (G.B.)

  3. In vitro evaluation of radiopacity of different filling materials by resources of digital radiography = Avaliação in vitro da radiopacidade de diferentes materiais obturadores através de recursos de radiografia digital

    Directory of Open Access Journals (Sweden)

    Souza, Matheus Albino

    2015-01-01

    Full Text Available Objetivo: Avaliar a radiopacidade de diferentes sistemas obturadores endodônticos por meio de radiografia digital em um modelo de dentes humanos. Metodologia: Setenta dentes humanos unirradiculares extraídos foram selecionados, a abertura coronária foi feita e o comprimento de trabalho foi determinado 1 mm aquém do forame apical. Após o preparo químicomecânico os dentes foram divididos em 7 grupos [n=10] de acordo com o material obturador utilizado: G1, Epiphany; G2, AH Plus; G3, EndoRez; G4, EndoFill; G5, Endomethasone; G6, Sealapex; G7, Sealer 26. No G1 foram utilizados cones de Resilon e nos demais grupos cones de guta-percha. Sete dias após a obturação foram feitas radiografias digitais e as imagens foram introduzidas num software para a leitura dos resultados. Para avaliar a radiopacidade, o software digitale DBSWIN gerou um gráfico colorimétrico para cada amostra, relacionando o gradiente de cor observado na amostra com o respectivo escore numérico contido em uma escala desse gráfico. Os dados foram analisados estaticamente pelo teste ANOVA e Tukey’s ao nível de 5% de significância. Resultados: O sistema Epiphany/Resilon foi superior estatisticamente aos grupos do AH Plus, EndoRez, Sealapex e Sealer 26 em termos de radiopacidade [P<0,05]. Conclusão: O cimento endodôntico Epiphany, associado aos cones Resilon, apresentou os maiores valores de radiopacidade

  4. Improving the support characteristics of hydraulic fill

    Energy Technology Data Exchange (ETDEWEB)

    Corson, D. R.; Dorman, K. R.; Sprute, R. H.

    1980-05-15

    Extensive laboratory and field testing has defined the physical properties of hydraulic fill. Effect of void ratio on percolation rate has been quantified, and tests were developed to estimate waterflow through fill material in a given state underground. Beneficial effect on fill's support capability through addition of cement alone or in conjunction with vibratory compaction has been investigated. Two separate field studies in operating cut-and-fill mines measured vein-wall deformation and loads imposed on backfilled stopes. Technology has been developed that will effectively and efficiently dewater and densify ultra-fine-grained slurries typical of metal mine hydraulic backfill. At least two operators are using this electrokinetic technique to dewater slimes collected in underground sumps or impoundments. This technique opens up the possibility of using the total unclassified tailings product as a hydraulic backfill. Theoretical enhancement of ground support and rock-burst control through improved support capability will be tested in a full-scale mine stope installation. Both a horizontal layer and a vertical column of high modulus fill will be placed in an attempt to reduce stope wall closure, support more ground pressure, and lessen rock-burst occurrence.

  5. 46 CFR 151.03-21 - Filling density.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Filling density. 151.03-21 Section 151.03-21 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES BARGES CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Definitions § 151.03-21 Filling density. The ratio, expressed as...

  6. Boron filled siloxane polymers for radiation shielding

    Science.gov (United States)

    Labouriau, Andrea; Robison, Tom; Shonrock, Clinton; Simmonds, Steve; Cox, Brad; Pacheco, Adam; Cady, Carl

    2018-03-01

    The purpose of the present work was to evaluate changes to structure-property relationships of 10B filled siloxane-based polymers when exposed to nuclear reactor radiation. Highly filled polysiloxanes were synthesized with the intent of fabricating materials that could shield high neutron fluences. The newly formulated materials consisted of cross-linked poly-diphenyl-methylsiloxane filled with natural boron and carbon nanofibers. This polymer was chosen because of its good thermal and chemical stabilities, as well as resistance to ionizing radiation thanks to the presence of aromatic groups in the siloxane backbone. Highly isotopically enriched 10B filler was used to provide an efficient neutron radiation shield, and carbon nanofibers were added to improve mechanical strength. This novel polymeric material was exposed in the Annular Core Research Reactor (ACRR) at Sandia National Labs to five different neutron/gamma fluxes consisting of very high neutron fluences within very short time periods. Thermocouples placed on the specimens recorded in-situ temperature changes during radiation exposure, which agreed well with those obtained from our MCNP simulations. Changes in the microstructural, thermal, chemical, and mechanical properties were evaluated by SEM, DSC, TGA, FT-IR NMR, solvent swelling, and uniaxial compressive load measurements. Our results demonstrate that these newly formulated materials are well-suitable to be used in applications that require exposure to different types of ionizing conditions that take place simultaneously.

  7. Dielectric-filled radiofrequency linacs

    Energy Technology Data Exchange (ETDEWEB)

    Faehl, R J; Keinigs, R K; Pogue, E W [Los Alamos National Lab., NM (United States)

    1997-12-31

    High current, high brightness electron beam accelerators promise to open up dramatic new applications. Linear induction accelerators are currently viewed as the appropriate technology for these applications. A concept by Humphries and Hwang may permit radiofrequency accelerators to fulfill the same functions with greater simplicity and enhanced flexibility. This concept involves the replacement of vacuum rf cavities with dielectric filled ones. Simple analysis indicates that the resonant frequencies are reduced by a factor of ({epsilon}{sub 0}/{epsilon}){sup 1/2} while the stored energy is increased by {epsilon}/{epsilon}{sub 0}. For a high dielectric constant like water, this factor can approach 80. A series of numerical calculations of simple pill-box cavities was performed. Eigenfunctions and resonant frequencies for a full system configuration, including dielectric material, vacuum beamline, and a ceramic window separating the two have been computed. These calculations are compared with the results of a small experimental cavity which have been constructed and operated. Low power tests show excellent agreement. (author). 4 figs., 8 refs.

  8. Gas-filled hohlraum fabrication

    International Nuclear Information System (INIS)

    Salazar, M.A.; Gobby, P.L.; Foreman, L.R.; Bush, H. Jr.; Gomez, V.M.; Moore, J.E.; Stone, G.F.

    1995-01-01

    Los Alamos National Laboratory (LANL) researchers have fabricated and fielded gas-filled hohlraums at the Lawrence Livermore National Laboratory (LLNL) Nova laser. Fill pressures of 1--5 atmospheres have been typical. We describe the production of the parts, their assembly and fielding. Emphasis is placed on the production of gas-tight polyimide windows and the fielding apparatus and procedure

  9. Time effects of water drainage from deposited back-fill

    International Nuclear Information System (INIS)

    Baranski, L.A.

    1976-01-01

    Time effects of water drainage from deposited back-fill in mine excavations are considered. The time dependence of drainage from the deposited material was determined from ''in situ'' measurements with the aid of radioisotope gauges. The measurements were performed for given drainage conditions and practically constant grain size composition. It was found that in a few hours after the end of the back-filling operation the mechanical properties of the deposited material are practically constant. (author)

  10. Recent developments in inorganically filled carbon nanotubes: successes and challenges

    Directory of Open Access Journals (Sweden)

    Ujjal K Gautam, Pedro M F J Costa, Yoshio Bando, Xiaosheng Fang, Liang Li, Masataka Imura and Dmitri Golberg

    2010-01-01

    Full Text Available Carbon nanotubes (CNTs are a unique class of nanomaterials that can be imagined as rolled graphene sheets. The inner hollow of a CNT provides an extremely small, one-dimensional space for storage of materials. In the last decade, enormous effort has been spent to produce filled CNTs that combine the properties of both the host CNT and the guest filling material. CNTs filled with various inorganic materials such as metals, alloys, semiconductors and insulators have been obtained using different synthesis approaches including capillary filling and chemical vapor deposition. Recently, several potential applications have emerged for these materials, such as the measurement of temperature at the nanoscale, nano-spot welding, and the storage and delivery of extremely small quantities of materials. A clear distinction between this class of materials and other nanostructures is the existence of an enormous interfacial area between the CNT and the filling matter. Theoretical investigations have shown that the lattice mismatch and strong exchange interaction of CNTs with the guest material across the interface should result in reordering of the guest crystal structure and passivation of the surface dangling bonds and thus yielding new and interesting physical properties. Despite preliminary successes, there remain many challenges in realizing applications of CNTs filled with inorganic materials, such as a comprehensive understanding of their growth and physical properties and control of their structural parameters. In this article, we overview research on filled CNT nanomaterials with special emphasis on recent progress and key achievements. We also discuss the future scope and the key challenges emerging out of a decade of intensive research on these fascinating materials.

  11. Better building of valley fills

    Energy Technology Data Exchange (ETDEWEB)

    Chironis, N.P.

    1980-03-01

    Current US regulations for building valley fills or head of hollow fills to hold excess spoil resulting from contour mining are meeting with considerable opposition, particularly from operators in steep-slope areas. An alternative method has been submitted to the Office of Surface Mining by Virgina. Known as the zoned concept method, it has already been used successfully in building water-holding dams and coal refuse embankments on sloping terrain. The ways in which drainage and seepage are managed are described.

  12. Magnetically Active and Coated Gadolinium-Filled Carbon Nanotubes

    KAUST Repository

    Fidiani, Elok; Da Costa, Pedro M. F. J.; Wolter, Anja U. B.; Maier, Diana; Buechner, Bernd; Hampel, Silke

    2013-01-01

    Gd-filled carbon nanotubes (which include the so-called gadonanotubes(1)) have been attracting much interest due to their potential use in medical diagnostic applications. In the present work, a vacuum filling method was performed to confine gadolinium(III) iodide in carbon nanotubes (CNTs). Filling yields in excess of 50% were obtained. Cleaning and dosing of the external walls was undertaken, as well as the study of the filled CNT magnetic properties. Overall, we found that the encapsulating procedure can lead to reduction of the lanthanide metal and induce disorder in the initial GdI3-type structure. Notwithstanding, the magnetic response of the material is not compromised, retaining a strong paramagnetic response and an effective magnetic moment of similar to 6 mu B. Our results may entice further investigation into whether an analogous Gd3+ to Gd2+ reduction takes place in other Gd-filled CNT systems.

  13. Magnetically Active and Coated Gadolinium-Filled Carbon Nanotubes

    KAUST Repository

    Fidiani, Elok

    2013-08-15

    Gd-filled carbon nanotubes (which include the so-called gadonanotubes(1)) have been attracting much interest due to their potential use in medical diagnostic applications. In the present work, a vacuum filling method was performed to confine gadolinium(III) iodide in carbon nanotubes (CNTs). Filling yields in excess of 50% were obtained. Cleaning and dosing of the external walls was undertaken, as well as the study of the filled CNT magnetic properties. Overall, we found that the encapsulating procedure can lead to reduction of the lanthanide metal and induce disorder in the initial GdI3-type structure. Notwithstanding, the magnetic response of the material is not compromised, retaining a strong paramagnetic response and an effective magnetic moment of similar to 6 mu B. Our results may entice further investigation into whether an analogous Gd3+ to Gd2+ reduction takes place in other Gd-filled CNT systems.

  14. Safety Distances for hydrogen filling stations

    Energy Technology Data Exchange (ETDEWEB)

    Matthijsen, A. J. C. M.; Kooi, E. S.

    2005-07-01

    In the Netherlands there is a growing interest in using natural gas as a transport fuel. The most important drivers behind this development are formed by poor inner city air quality and the decision to close several LPG filling stations. Dwellings are not allowed within the safety distances of 45 or 110 meters from the tanker filling point of these LPG stations, depending on the capacity of the station. Another driver is global warming. We are carrying out a study on station supply, compression, storage and filling for natural gas stations, and a similar, simultaneous study on hydrogen as a followup to our risk analysis for the hydrogen filling station in Amsterdam. Here, three buses drive on hydrogen as part of the European CUTE project. Driving on natural gas is an important step in the transition to cars on hydrogen. This study was commissioned by the Dutch Ministry of Spatial Planning, Housing and the Environment to advise on external safety aspects of future hydrogen filling stations. According to Dutch law homes may not be built within an individual risk contour of 10-6 per year of a dangerous object, such as a plant with hazardous materials or a filling station. An individual risk contour of 10-6 is represented by a line around a dangerous object that connects locations with an individual risk level of 10-6 per year. An individual 'located' within this contour line has a chance of one per million per year or more to be killed as a result of an accident caused by this object. The longest distance between the object and such a contour is called a 'safety distance'. A study on safety distances is now in progress for different kinds of hydrogen filling stations (e. g. gaseous and liquid hydrogen) and for different capacities, such as big, medium and small stations. The focus is on different kinds of hydrogen production and the hydrogen supply of the filling station. To decide on the design and supply of the hydrogen station, we examined the

  15. Materialism.

    Science.gov (United States)

    Melnyk, Andrew

    2012-05-01

    Materialism is nearly universally assumed by cognitive scientists. Intuitively, materialism says that a person's mental states are nothing over and above his or her material states, while dualism denies this. Philosophers have introduced concepts (e.g., realization and supervenience) to assist in formulating the theses of materialism and dualism with more precision, and distinguished among importantly different versions of each view (e.g., eliminative materialism, substance dualism, and emergentism). They have also clarified the logic of arguments that use empirical findings to support materialism. Finally, they have devised various objections to materialism, objections that therefore serve also as arguments for dualism. These objections typically center around two features of mental states that materialism has had trouble in accommodating. The first feature is intentionality, the property of representing, or being about, objects, properties, and states of affairs external to the mental states. The second feature is phenomenal consciousness, the property possessed by many mental states of there being something it is like for the subject of the mental state to be in that mental state. WIREs Cogn Sci 2012, 3:281-292. doi: 10.1002/wcs.1174 For further resources related to this article, please visit the WIREs website. Copyright © 2012 John Wiley & Sons, Ltd.

  16. Optimization of foam-filled bitubal structures for crashworthiness criteria

    International Nuclear Information System (INIS)

    Zhang, Yong; Sun, Guangyong; Li, Guangyao; Luo, Zhen; Li, Qing

    2012-01-01

    Highlights: ► The paper aims to optimize foam-filled bitubal squared column for crashworthiness. ► It explores different formulations and configurations of design. ► The optimal foam-filled bitubal column is better than foam-filled monotubal column. ► The optimal foam-filled bitubal column is better than empty bitubal column. -- Abstract: Thin-walled structures have been widely used as key components in automobile and aerospace industry to improve the crashworthiness and safety of vehicles while maintaining overall light-weight. This paper aims to explore the design issue of thin-walled bitubal column structures filled with aluminum foam. As a relatively new filler material, aluminum foam can increase crashworthiness without sacrificing too much weight. To optimize crashworthiness of the foam-filled bitubal square column, the Kriging meta-modeling technique is adopted herein to formulate the objective and constraint functions. The genetic algorithm (GA) and Non-dominated Sorting Genetic Algorithm II (NSGA II) are used to seek the optimal solutions to the single and multiobjective optimization problems, respectively. To compare with other thin-walled configurations, the design optimization is also conducted for empty bitubal column and foam-filled monotubal column. The results demonstrate that the foam-filled bitubal configuration has more room to enhance the crashworthiness and can be an efficient energy absorber.

  17. Bulk-fill resin composites: polymerization contraction, depth of cure, and gap formation.

    Science.gov (United States)

    Benetti, A R; Havndrup-Pedersen, C; Honoré, D; Pedersen, M K; Pallesen, U

    2015-01-01

    The bulk-filling of deep, wide dental cavities is faster and easier than traditional incremental restoration. However, the extent of cure at the bottom of the restoration should be carefully examined in combination with the polymerization contraction and gap formation that occur during the restorative procedure. The aim of this study, therefore, was to compare the depth of cure, polymerization contraction, and gap formation in bulk-fill resin composites with those of a conventional resin composite. To achieve this, the depth of cure was assessed in accordance with the International Organization for Standardization 4049 standard, and the polymerization contraction was determined using the bonded-disc method. The gap formation was measured at the dentin margin of Class II cavities. Five bulk-fill resin composites were investigated: two high-viscosity (Tetric EvoCeram Bulk Fill, SonicFill) and three low-viscosity (x-tra base, Venus Bulk Fill, SDR) materials. Compared with the conventional resin composite, the high-viscosity bulk-fill materials exhibited only a small increase (but significant for Tetric EvoCeram Bulk Fill) in depth of cure and polymerization contraction, whereas the low-viscosity bulk-fill materials produced a significantly larger depth of cure and polymerization contraction. Although most of the bulk-fill materials exhibited a gap formation similar to that of the conventional resin composite, two of the low-viscosity bulk-fill resin composites, x-tra base and Venus Bulk Fill, produced larger gaps.

  18. Gas-Filled Capillary Model

    International Nuclear Information System (INIS)

    Steinhauer, L. C.; Kimura, W. D.

    2006-01-01

    We have developed a 1-D, quasi-steady-state numerical model for a gas-filled capillary discharge that is designed to aid in selecting the optimum capillary radius in order to guide a laser beam with the required intensity through the capillary. The model also includes the option for an external solenoid B-field around the capillary, which increases the depth of the parabolic density channel in the capillary, thereby allowing for propagation of smaller laser beam waists. The model has been used to select the parameters for gas-filled capillaries to be utilized during the Staged Electron Laser Acceleration -- Laser Wakefield (STELLA-LW) experiment

  19. Filling of charged cylindrical capillaries

    NARCIS (Netherlands)

    Das, Siddhartha; Chanda, Sourayon; Eijkel, J.C.T.; Tas, N.R.; Chakraborty, Suman; Mitra, Sushanta K.

    2014-01-01

    We provide an analytical model to describe the filling dynamics of horizontal cylindrical capillaries having charged walls. The presence of surface charge leads to two distinct effects: It leads to a retarding electrical force on the liquid column and also causes a reduced viscous drag force because

  20. Space-filling polyhedral sorbents

    Energy Technology Data Exchange (ETDEWEB)

    Haaland, Peter

    2016-06-21

    Solid sorbents, systems, and methods for pumping, storage, and purification of gases are disclosed. They derive from the dynamics of porous and free convection for specific gas/sorbent combinations and use space filling polyhedral microliths with facial aplanarities to produce sorbent arrays with interpenetrating interstitial manifolds of voids.

  1. ADVANTAGES AND DISADVANTAGES OF THE SONICFILL™ METHOD FOR LATERAL FILLINGS

    Directory of Open Access Journals (Sweden)

    Nicolae BARANOV

    2017-06-01

    Full Text Available The aim of the study was to evaluate the advantages and disadvantages of bulk-fill type fillings realized with SONICFill™ over an 18 month interval, on a batch of patients with different ages and occupations. Materials and methods: the study was performed on a batch of 73 patients who addressed the Clinical of OdontologyEndodontics within the Platform of Practical Training (PIP of the Faculty of Dental Medicine of the ”Apollonia” University of Iaşi, between Octomber 1, 2014 - May 1, 2016, subjected to 91 bulk-fill fillings with SonicFill™ on the posterior teeth. Results and discussion: out of the total number of 73 patients, 56 came from the urban environment, and 17 - from the rural medium, the highest ratio being represented by the 21-30 year age group (45%, closely followed by the 31-40 year one (40%. As for gender distribution within the batch, nearly two-thirds are women, the rest being men. The education level influenced patients’ decision – that of accepting a new method of filling application. As to the types of teeth to which restorations were applied, the highest ratio is represented by lower molars (41%, followed by upper molars (23% and mandibular premolars (20%, the lowest number of restorations being applied to maxillary premolars. Out of the total number of 91 bulk-fill restorations, 28 were applied over a base filling while, in 63 restorations, the basic filling was absent. Conclusions: The SonicFill ™ system for bulk-fill posterior restorations has a number of advantages, such as: high photopolymerization depth, significant reduction of setting contraction, better composite adaptation to the cavity walls, long-term predictable clinical results.

  2. Incidence of apical crack initiation and propagation during the removal of root canal filling material with ProTaper and Mtwo rotary nickel-titanium retreatment instruments and hand files.

    Science.gov (United States)

    Topçuoğlu, Hüseyin Sinan; Düzgün, Salih; Kesim, Bertan; Tuncay, Oznur

    2014-07-01

    The aim of this study was to determine the incidence of crack initiation and propagation in apical root dentin after retreatment procedures performed by using 2 rotary retreatment systems and hand files with additional instrumentation. Eighty extracted mandibular premolars with single canals were selected. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the control group, and no preparation was performed. The remaining 60 teeth were prepared to size 35 with rotary files and filled with gutta-percha and AH Plus sealer. Specimens were then divided into 3 groups (n = 20), and retreatment procedures were performed with the following devices and techniques: ProTaper Universal retreatment files, Mtwo retreatment files, and hand files. After retreatment, the additional instrumentation was performed by using size 40 ProTaper, Mtwo, and hand files. Digital images of the apical root surface were recorded before preparation, after instrumentation, after filling, after retreatment, and after additional instrumentation. The images were then inspected for the presence of any new apical cracks and propagation. Data were analyzed with the logistic regression and Fisher exact tests. All experimental groups caused crack initiation and propagation after use of retreatment instruments. The ProTaper and Mtwo retreatment groups caused greater crack initiation and propagation than the hand instrument group (P ProTaper and Mtwo instruments after the use of retreatment instruments caused crack initiation and propagation, whereas hand files caused neither crack initiation nor propagation (P < .05). This study showed that retreatment procedures and additional instrumentation after the use of retreatment files may cause crack initiation and propagation in apical dentin. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Materials

    CSIR Research Space (South Africa)

    Van Wyk, Llewellyn V

    2009-02-01

    Full Text Available . It is generally included as part of a structurally insulated panel (SIP) where the foam is sandwiched between external skins of steel, wood or cement. Cement composites Cement bonded composites are an important class of building materials. These products... for their stone buildings, including the Egyptians, Aztecs and Inca’s. As stone is a very dense material it requires intensive heating to become warm. Rocks were generally stacked dry but mud, and later cement, can be used as a mortar to hold the rocks...

  4. Understanding the safety and tolerability of facial filling therapeutics.

    Science.gov (United States)

    Kulichova, Daniela; Borovaya, Alyona; Ruzicka, Thomas; Thomas, Peter; Gauglitz, Gerd G

    2014-09-01

    Aesthetic medicine represents an emerging field for many specialties. Nowadays, a plethora of approaches are available to rejuvenate the human body and face, the latter being a frequent target for the placement of filling substances to correct wrinkles and volume loss. Nevertheless, based on the many products on the market, treating clinicians must pay specific attention to the properties of the respective materials, their associated side effects and any specific handling requirements to prevent potential short- and long-term adverse events. Types of filling materials, including biodegradable and non-biodegradable products, related complications, their conservative and invasive treatment options, as well as prevention strategies are described in this review. A profound knowledge of the facial anatomy as well as extensive experience with the various filling techniques and suitable materials for the respective areas remains crucial to prevent adverse events associated with filling procedures to the human face. Since side effects such as malar edema and foreign body granuloma do affect patients physically and psychologically to a significant extent and their successful treatment still remains challenging, further in depth studies on the tolerability of many filling materials utilized are required.

  5. Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance.

    Science.gov (United States)

    Ilie, N; Bucuta, S; Draenert, M

    2013-01-01

    The study aimed to assess the mechanical performance of seven bulk-fill RBCs (Venus Bulk Fill, Heraeus Kulzer; SureFil SDR flow, Dentsply Caulk; x-tra base and x-tra fil, VOCO; Filtek Bulk Fill, 3M ESPE; SonicFill, Kerr; Tetric EvoCeram Bulk Fill, Ivoclar Vivadent) by determining their flexural strength (σ), reliability (Weibull parameter, m), flexural modulus (Eflexural), indentation modulus (YHU), Vickers hardness (HV), and creep (Cr). The significant highest flexural strengths were measured for SonicFill, x-tra base, and x-tra fil, while x-tra base, SureFil SDR flow, and Venus Bulk Fill showed the best reliability. The differences among the materials became more evident in terms of Eflexural and YHU, with x-tra fil achieving the highest values, while Filtek Bulk Fill and Venus Bulk Fill achieved the lowest. The enlarged depth of cure in bulk-fill RBCs seems to have been realized by enhancing the materials' translucency through decreasing the filler amount and increasing the filler size. The manufacturer's recommendation to finish a bulk-fill RBC restoration by adding a capping layer made of regular RBCs is an imperative necessity, since the modulus of elasticity and hardness of certain materials (SureFil SDR flow, Venus Bulk Fill, and Filtek Bulk Fill) were considerably below the mean values measured in regular nanohybrid and microhybrid RBCs. The class of bulk-fill RBCs revealed similar flexural strength values as the class of nanohybrid and microhybrid RBCs, and significantly higher values when compared to flowable RBCs. The modulus of elasticity (Eflexural), the indentation modulus (YHU), and the Vickers hardness (HV) classify the bulk-fill RBCs as between the hybrid RBCs and the flowable RBCs; in terms of creep, bulk-fill and the flowable RBCs perform similarly, both showing a significantly lower creep resistance when compared to the nanohybrid and microhybrid RBCs.

  6. Hard-to-fill vacancies.

    Science.gov (United States)

    Williams, Ruth

    2010-09-29

    Skills for Health has launched a set of resources to help healthcare employers tackle hard-to-fill entry-level vacancies and provide sustainable employment for local unemployed people. The Sector Employability Toolkit aims to reduce recruitment and retention costs for entry-level posts and repare people for employment through pre-job training programmes, and support employers to develop local partnerships to gain access to wider pools of candidates and funding streams.

  7. Hydraulic fracturing of rock-fill dam

    Directory of Open Access Journals (Sweden)

    Jun-Jie WANG

    2016-02-01

    Full Text Available The condition in which hydraulic fracturing in core of earth-rock fill dam maybe induced, the mechanism by which the reason of hydraulic fracturing canbe explained, and the failure criterion by which the occurrence of hydraulicfracturing can be determined, were investigated. The condition dependson material properties such as, cracks in the core and low permeability ofcore soil, and “water wedging” action in cracks. An unsaturated core soiland fast impounding are the prerequisites for the formation of “waterwedging” action. The mechanism of hydraulic fracturing can be explainedby fracture mechanics. The crack propagation induced by water pressuremay follow any of mode I, mode II and mixed mode I-II. Based on testingresults of a core soil, a new criterion for hydraulic fracturing was suggested,from which mechanisms of hydraulic fracturing in the core of rock-fill damwere discussed. The results indicated that factors such as angle betweencrack surface and direction of principal stress, local stress state at thecrack, and fracture toughness KIC of core soil may largely affect theinduction of hydraulic fracturing and the mode of the propagation of thecrack.The condition in which hydraulic fracturing in core of earth-rock fill dam maybe induced, the mechanism by which the reason of hydraulic fracturing canbe explained, and the failure criterion by which the occurrence of hydraulicfracturing can be determined, were investigated. The condition dependson material properties such as, cracks in the core and low permeability ofcore soil, and “water wedging” action in cracks. An unsaturated core soiland fast impounding are the prerequisites for the formation of “waterwedging” action. The mechanism of hydraulic fracturing can be explainedby fracture mechanics. The crack propagation induced by water pressuremay follow any of mode I, mode II and mixed mode I-II. Based on testingresults of a core soil, a new criterion for hydraulic fracturing

  8. Post-cure depth of cure of bulk fill dental resin-composites.

    Science.gov (United States)

    Alrahlah, A; Silikas, N; Watts, D C

    2014-02-01

    To determine the post-cure depth of cure of bulk fill resin composites through using Vickers hardness profiles (VHN). Five bulk fill composite materials were examined: Tetric EvoCeram(®) Bulk Fill, X-tra base, Venus(®) Bulk Fill, Filtek™ Bulk Fill, SonicFill™. Three specimens of each material type were prepared in stainless steel molds which contained a slot of dimensions (15 mm × 4 mm × 2 mm), and a top plate. The molds were irradiated from one end. All specimens were stored at 37°C for 24h, before measurement. The Vickers hardness was measured as a function of depth of material, at 0.3mm intervals. Data were analysed by one-way ANOVA using Tukey post hoc tests (α=0.05). The maximum VHN ranged from 37.8 to 77.4, whilst the VHN at 80% of max.VHN ranged from 30.4 to 61.9. The depth corresponding to 80% of max.VHN, ranged from 4.14 to 5.03 mm. One-way ANOVA showed statistically significant differences between materials for all parameters tested. SonicFill exhibited the highest VHN (pFill the lowest (p≤0.001). SonicFill and Tetric EvoCeram Bulk Fill had the greatest depth of cure (5.03 and 4.47 mm, respectively) and was significant's different from X-tra base, Venus Bulk Fill and Filtek Bulk Fill (p≤0.016). Linear regression confirmed a positive regression between max.VHN and filler loading (r(2)=0.94). Bulk fill resin composites can be cured to an acceptable post-cure depth, according to the manufacturers' claims. SonicFill and Tetric EvoCeram Bulk Fill had the greatest depth of cure among the composites examined. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. 30 CFR 817.72 - Disposal of excess spoil: Valley fill/head-of-hollow fills.

    Science.gov (United States)

    2010-07-01

    ... STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.72 Disposal of excess spoil: Valley fill/head-of-hollow fills.... Uncontrolled surface drainage may not be directed over the outslope of the fill. (2) Runoff from areas above the fill and runoff from the surface of the fill shall be diverted into stabilized diversion channels...

  10. Fissure fillings from the Klipperaas study site

    International Nuclear Information System (INIS)

    Tullborg, E.L.

    1986-07-01

    The Klipperaas study site is located within the Smaaland-Vaermland granitoid belt in southern Sweden. The area investigated can be subdivided into blocks with different hydraulic character and fracture frequency of the rocks. A fissure filling, study has been carried out within the area. This includes identification of the minerals, mineral frequency, textures within the fissures and isotope analyses of calcites. Four generation of fissure fillings, within the time space c. 1600 M.a. to present, has been distinguished. These are 1) quartz; 2) epidote + muscovite and adularia + hematite; 3) calcite + chlorite +/hematite; 4) calcite, clay minerals and Fe-oxyhydroxide. It is observed that the surface water affect the uppermost part of the bedrock resulting in calcite dissolution, break down of pyrite and precipitation of Fe-oxyhydroxide. It is also obvious from the fracture calcite frequency that calcite dissolution is more intensive close to and within the fracture zones. There, Fe-oxyhydroxide can be found down to at least 400 m depth. This gives valuable information about the physic-chemical character of the groundwater within the bedrock. Several fracture zones have been reactivated. It is also suspected that relatively late movements have taken place causing crushing of the rock and only a slight cementation of the crushed material is visible. Some of the fracture zones correspond to mafic dikes. These zones exhibit lower hydraulic conductivity than other zones due to fracture sealing by clay minerals but also by chlorite and calcite. (author)

  11. Charge balancing fill rate monitor

    International Nuclear Information System (INIS)

    Rothman, J.L.; Blum, E.B.

    1995-01-01

    A fill rate monitor has been developed for the NSLS storage rings to allow machine tuning over a very large dynamic range of beam current. Synchrotron light, focused on a photodiode, produces a signal proportional to the beam current. A charge balancing circuit processes the diode current, creating an output signal proportional to the current injected into the ring. The unit operates linearly over a dynamic range of 120 dB and can resolve pulses of injected beam as small as 1 μA

  12. Modelling the filling rate of pit latrines | Brouckaert | Water SA

    African Journals Online (AJOL)

    Excreta (faeces and urine) that are deposited into a pit latrine are subject to biodegradation, which substantially reduces the volume that remains. On the other hand, other matter that is not biodegradable usually finds itsway into pit latrines. The net filling rate is thus dependent on both the rate of addition of material and its ...

  13. The Effects of Iron Filling On Some Mechanical and Physical ...

    African Journals Online (AJOL)

    acer

    sawdust of particle size 1.18mm and iron fillings of size 300µm, 20g binder (urea formaldehyde) concentration, hot ... The water absorption and thickness swell test results showed that the .... of this type of magnetic material include: easier.

  14. [Contributions and difficulties of the social approach in psychiatry: apropos of the American forces and veterans in Vietnam. 2. Psychosociological, psychiatric and medico-legal aspects in veterans].

    Science.gov (United States)

    Juillet, P

    1987-10-01

    In many veterans, the post-Vietnam era is that of "post-traumatic stress disorder" (P.T.S.D.), chronic or delayed, practically corresponding to the traumatic neurosis, dominated at all times by the intrusive-repetitive syndrome. This phenomenon is considered as concerning at least 800,000 persons. Acting out, in fact less common than it was feared, may be associated with it, as well as delinquency, likely more frequent than in the general population, alcoholism and substance abuse. Regarding the latter, the notion of a "legacy of Vietnam" is very questionable. Its decrease, which is sometimes spontaneous, puts the question of dependency, including opiates. The evidence of a possible P.T.S.D. behind these miscellaneous behavior disorders which evoke more an antisocial personality, is ticklish. With regard to epidemiology, the part of psychiatric sequels of Vietnam is so much the more difficult to appreciate as the affective and social support provided to these people at the time of their return "into the world" is often poor. A partial induction of such troubles, inspired with ideological or utilitarian purposes, is not excluded.

  15. Number of addictive substances used related to increased risk of unnatural death: A combined medico-legal and case-record study

    Directory of Open Access Journals (Sweden)

    Lindgren Anna

    2009-08-01

    Full Text Available Abstract Background Substance use disorders have repeatedly been found to lead to premature death, i.e. drug-related death by disease, fatal intoxications, or trauma (accidents, suicide, undetermined suicide, and homicide. The present study examined the relationship between multi-drug substance use and natural and unnatural death. Methods All consecutive, autopsied patients who had been in contact with the Addiction Centre in Malmö University Hospital from 1993 to 1997 inclusive were investigated. Drug abuse was investigated blindly in the case records and related to the cause of death in 387 subjects. Results Every substance apart from alcohol used previously in life added to the risk of unnatural death in a linear way. There were independent increased risks of fatal heroin overdoses or undetermined suicide. Death by suicide and violent death were unrelated to additional abuse. Conclusion The number of drugs used was related to an increased risk of unnatural death by undetermined suicide (mainly fatal intoxications and heroin overdose.

  16. "Legal highs"--toxicity in the clinical and medico-legal aspect as exemplified by suicide with bk-MBDB administration.

    Science.gov (United States)

    Rojek, Sebastian; Kłys, Małgorzata; Strona, Marcin; Maciów, Martyna; Kula, Karol

    2012-10-10

    The easily available "legal highs", which are products containing psychoactive substances, such as cathinones, piperazines and synthetic cannabinoids, are abused by adolescents in Poland and in the world as alternatives to classic drugs, such as amphetamines or marijuana. The majority of these potentially dangerous substances are still legal and they are associated with a risk of severe poisoning or even death, and provide new challenges in clinical and forensic toxicological practice. Investigations in the field of "designer drugs" may be well illustrated by the case of a suicide of a 21-year old male who ingested a specified dose of a preparation called "Amphi-bi-a" that contains bk-MBDB, chemically 2-methylamino-1-(3,4-methylenedioxyphenyl) butan-1-one, which belongs to the cathinone group, as a synthetic euphoric empathogen and psychoactive stimulant that is chemically similar to MDMA. It is one of more common components of "legal highs" examined in Poland and other countries. The documentation of the case includes a clinical assessment of the patient's health status performed during his almost 4-h hospitalization before death, autopsy and histological examinations supported by toxicological findings revealing bk-MBDB at extremely high concentrations (at 20 mg/l in the blood and 33 mg/kg in the liver); hence, this body of evidence contributes to knowledge in the field of "designer drugs". Inventions of designers of new psychoactive xenobiotics, which are much in demand, especially in view of the dynamic Internet marketing, which drums up narcobusiness, must be balanced by a national strategy developed by medical, legal and educational circles in the modern civilized world in order to prevent the spreading of the phenomenon. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. The management, privacy and medico-legal issues of electronic CPAP data in Australia and New Zealand: Electronic CPAP data management in Australia and New Zealand.

    Science.gov (United States)

    Swieca, John; Hamilton, Garun S; Meaklim, Hailey

    2017-08-01

    Continuous Positive Airway Pressure (CPAP) is considered to be the gold standard treatment for obstructive sleep apnoea (OSA). CPAP monitoring systems allow tracking of patient CPAP adherence and treatment efficacy, by measuring residual sleep-disordered breathing, hours of CPAP use, and mask leak etc. The American Thoracic Society (ATS) published a position paper in 2013 highlighting issues of interpreting CPAP data such as a lack of consistency between CPAP manufacturers data algorithms, legal implications of CPAP data and implications for CPAP adherence. This paper extends on this work by investigating these issues in an Australasian context. A review of current literature on CPAP monitoring systems, privacy and security of CPAP data for major Australasian CPAP providers, and CPAP adherence was undertaken. A legal review was also commissioned for issues related to privacy and security of CPAP data. CPAP manufacturers' utilize different algorithms for respiratory event detection and clinicians need to be aware the implications for interpreting CPAP data. Australasian CPAP manufacturers have created security/privacy policies with the intent to follow relevant legislation to protect patients' CPAP data, however they do need to be constantly reviewed and updated to avoid data breaches and changes to agreements. No guarantees can be provided by the Australasian Sleep Association on CPAP manufacturers' compliance with these policies and there is the potential for some degree of liability for physicians and CPAP providers associated with CPAP data. Lastly, providing patients with feedback on their CPAP usage and OSA management appears to have positive influence CPAP adherence. CPAP data provides many opportunities to increase OSA patient care and to help patients self-manage this chronic condition. However, issues relating to lack of standardization of CPAP parameters, privacy, security, and legal implications will need to be managed in this changing technologic and clinical environment. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Elution of monomer from different bulk fill dental composite resins.

    Science.gov (United States)

    Cebe, Mehmet Ata; Cebe, Fatma; Cengiz, Mehmet Fatih; Cetin, Ali Rıza; Arpag, Osman Fatih; Ozturk, Bora

    2015-07-01

    The purpose of this study was to evaluate the elution of Bis-GMA, TEGDMA, HEMA, and Bis-EMA monomers from six bulk fill composite resins over four different time periods, using HPLC. Six different composite resin materials were used in the present study: Tetric Evo Ceram Bulk Fill (Ivoclar Vivadent, Amherst, NY), X-tra Fill (VOCO, Cuxhaven, Germany), Sonic Fill (Kerr, Orange, CA, USA), Filtek Bulk Fill (3M ESPE Dental Product, St. Paul, MN), SDR (Dentsply, Konstanz, Germany), EQUIA (GC America INC, Alsip, IL). The samples (4mm thickness, 5mm diameter) were prepared and polymerized for 20s with a light emitted diode unit. After fabrication, each sample was immediately immersed in 75wt% ethanol/water solution used as extraction fluid and stored in the amber colored bottles at room temperature. Ethanol/water samples were taken (0.5mL) at predefined time intervals:10m (T1), 1h (T2), 24h (T3) and 30 days (T4). These samples were analyzed by HPLC. The obtained data were analyzed with one-way ANOVA and Tukey HSD at significance level of pcomposites (pcomposite resins in all time periods and the amount of eluted monomers was increased with time. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  19. Vertical Scan-Conversion for Filling Purposes

    OpenAIRE

    Hersch, R. D.

    1988-01-01

    Conventional scan-conversion algorithms were developed independently of filling algorithms. They cause many problems, when used for filling purposes. However, today's raster printers and plotters require extended use of filling, especially for the generation of typographic characters and graphic line art. A new scan-conversion algorithm, called vertical scan-conversion has been specifically designed to meet the requirements of parity scan line fill algorithms. Vertical scan-conversion ensures...

  20. 7 CFR 58.923 - Filling containers.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Filling containers. 58.923 Section 58.923 Agriculture... Procedures § 58.923 Filling containers. (a) The filling of small containers with product shall be done in a sanitary manner. The containers shall not contaminate or detract from the quality of the product in any way...

  1. Bulk fill restoratives: to cap or not to cap--that is the question?

    Science.gov (United States)

    Tomaszewska, Iwona M; Kearns, Jennifer O; Ilie, Nicoleta; Fleming, Garry J P

    2015-03-01

    To assess the cuspal deflection and cervical microleakage scores of standardised large mesio-occlusal-distal (MOD) cavities filled with different restoration protocols: (1) conventional resin restoratives, (2) bulk fill flowable base materials 'capped' with a conventional dimethacrylate resin-based composite (RBC) or (3) bulk fill resin restorative materials. Standardised MOD cavities were prepared in sixty-four sound maxillary premolar teeth and randomly allocated to eight groups. Restorations were placed in conjunction with a universal bonding system and resin restorative materials were irradiated with a quartz-tungsten-halogen light-curing-unit. Restoration protocol (eight oblique increments of conventional resin restorative, bulk fill flowable base and two occlusal 'capping' RBC increments (three increments in total) or bulk fill resin restorative (two increments)) was the dependent variable. A twin channel deflection measuring gauge measured the buccal and palatal cuspal deflections. Teeth were thermally fatigued, immersed in a 0.2% basic fuchsin dye for 24h, sectioned and examined for cervical microleakage score. Post hoc Tukey's tests highlighted significant differences in the mean total cuspal deflection values between resin restoratives (p fill flowable base materials with occlusal 'capping' RBC increments (restoration protocol 2) compared with bulk fill resin restoratives (restoration protocol 3). Not all bulk fill flowable materials or bulk fill resin restoratives behave in a similar fashion when used to restore standardised MOD cavities in maxillary premolar teeth and material selection is vital in the absence of clinical data. Poorly performing bulk fill flowable materials or bulk fill restoratives can be identified using the cuspal deflection and cervical microleakage protocol which could save the complications encountered clinically when restoring Class II restorations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Spectral radiative property control method based on filling solution

    International Nuclear Information System (INIS)

    Jiao, Y.; Liu, L.H.; Hsu, P.-F.

    2014-01-01

    Controlling thermal radiation by tailoring spectral properties of microstructure is a promising method, can be applied in many industrial systems and have been widely researched recently. Among various property tailoring schemes, geometry design of microstructures is a commonly used method. However, the existing radiation property tailoring is limited by adjustability of processed microstructures. In other words, the spectral radiative properties of microscale structures are not possible to change after the gratings are fabricated. In this paper, we propose a method that adjusts the grating spectral properties by means of injecting filling solution, which could modify the thermal radiation in a fabricated microstructure. Therefore, this method overcomes the limitation mentioned above. Both mercury and water are adopted as the filling solution in this study. Aluminum and silver are selected as the grating materials to investigate the generality and limitation of this control method. The rigorous coupled-wave analysis is used to investigate the spectral radiative properties of these filling solution grating structures. A magnetic polaritons mechanism identification method is proposed based on LC circuit model principle. It is found that this control method could be used by different grating materials. Different filling solutions would enable the high absorption peak to move to longer or shorter wavelength band. The results show that the filling solution grating structures are promising for active control of spectral radiative properties. -- Highlights: • A filling solution grating structure is designed to adjust spectral radiative properties. • The mechanism of radiative property control is studied for engineering utilization. • Different grating materials are studied to find multi-functions for grating

  3. Dynamic compaction with high energy of sandy hydraulic fills

    Directory of Open Access Journals (Sweden)

    Khelalfa Houssam

    2017-09-01

    Full Text Available A case study about the adoption of the dynamic compaction technique with high energy in a sandy hydraulic fill is presented. The feasibility of this technique to ensure the stability of the caisson workshop and to minimize the risk of liquefaction during manufacture. This Article is interested to establish diagnostic of dynamic compaction test, basing on the results of SPT tests and quality control as well as the details of work of compaction and the properties of filling materials. A theory of soil response to a high-energy impact during dynamic compaction is proposed.

  4. Review of fill mining technology in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Singh, K. H.; Hedley, D. G.F.

    1980-05-15

    The Canadian mining industry has a long history of being in the fore-front in developing new technology in underground hardrock mines. Examples include the development of hydraulic and cemented fills, undercut-and-fill, mechanized cut-and-fill, post pillar, vertical retreat and blasthole mining methods. The evolution of this technology is briefly described in an historical review. Backfill serves many functions, although it is generally considered in terms of its support capabilities. These functions, mainly related to the mining method used, are evaluated in regard to regional support, pillar support, fill roof, working floor, dilution control and waste disposal. With the advent of blasthole and vertical retreat methods for pillar recovery operations, the freestanding height of backfill walls has assumed greater importance. Consequently, more attention is being given to what fill properties are required to achieve fill wall exposures up to 25 m wide by 90 m high. With the large increases in energy costs, alternatives to partially replace Portland cement in fill are being examined. The validation of mining concepts and the interaction of backfill is perhaps best evaluated by in-situ measurements. Examples are given of stress, deformation and fill pressure measurements in longitudinal cut-and-fill, post pillar mining and blasthole stoping with delayed fill which were taken in several mines in Canada. Finally, the overall design procedure used in deciding mining method, stope and pillar dimensions, sequence of extraction, fill properties and support systems at a new mine is described.

  5. Investigating the effect of aeration powder filling on the actual compacting press; Eareto jutenho no jikki press deno hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, M. [Toyota Central Research and Development Labs., Inc., Nagoya (Japan); Urata, I. [Toyota Motor Co. Ltd., Aichi (Japan)

    1998-05-15

    The authors proposed an aeration filling method as a new filling method in order to obtain uniform and high speed filling by carrying out basic experiments on powder material filling using a visual apparatus. In this study, the aeration powder filling was applied to the product compacting on the actual compacting press, and its evaluation was carried out. As a result, the following effects were confirmed. The weight scattering was reduced to about 70% in the high speed filling and about 50% in the low speed filling. The maximum density was reduced to about 30% in the high speed filling and about 25% in the low speed filling. The maximum thickness difference was reduced to 65% in the high speed filling and about 20% in the low speed filling. The aeration powder effect was stronger in the high speed filling than that in the low speed filling. The weight and size accuracy of the components were increased by the aeration powder filling. The pause and the shaking operation were discarded in the front part of the powder box, thus the filling time could be remarkable shortened. 3 refs., 6 figs.

  6. The use of CT-scanning at the medicolegal external postmortem examination and at the forensic autopsy

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2006-01-01

    Introduction: Can CT-scanning of deceased at the medico legal external examination improve the selection of cases to autopsy? Is CT-scanning a substitute or a supplement to the traditional forensic autopsy? Material: In 2006 60 deceased individuals from Southern Denmark (counties of Fyn and Sønde...

  7. Physico-mechanical characteristics of commercially available bulk-fill composites.

    Science.gov (United States)

    Leprince, Julian G; Palin, William M; Vanacker, Julie; Sabbagh, Joseph; Devaux, Jacques; Leloup, Gaetane

    2014-08-01

    Bulk-fill composites have emerged, arguably, as a new "class" of resin-based composites, which are claimed to enable restoration in thick layers, up to 4mm. The objective of this work was to compare, under optimal curing conditions, the physico-mechanical properties of most currently available bulk-fill composites to those of two conventional composite materials chosen as references, one highly filled and one flowable "nano-hybrid" composite. Tetric EvoCeram Bulk Fill (Ivoclar-Vivadent), Venus Bulk Fill (Heraeus-Kulzer), SDR (Dentsply), X-tra Fil (VOCO), X-tra Base (VOCO), Sonic Fill (Kerr), Filtek Bulk Fill (3M-Espe), Xenius (GC) were compared to the two reference materials. The materials were light-cured for 40s in a 2mm×2mm×25mm Teflon mould. Degree of conversion was measured by Raman spectroscopy, Elastic modulus and flexural strength were evaluated by three point bending, surface hardness using Vickers microindentation before and after 24h ethanol storage, and filler weight content by thermogravimetric analysis. The ratio of surface hardness before and after ethanol storage was considered as an evaluation of polymer softening. Data were analyzed by one-way ANOVA and post hoc Tukey's test (p=0.05). The mechanical properties of the bulk-fill composites were mostly lower compared with the conventional high viscosity material, and, at best, comparable to the conventional flowable composite. Linear correlations of the mechanical properties investigated were poor with degree of conversion (0.090.8). Softening in ethanol revealed differences in polymer network density between material types. The reduction of time and improvement of convenience associated with bulk-fill materials is a clear advantage of this particular material class. However, a compromise with mechanical properties compared with more conventional commercially-available nano-hybrid materials was demonstrated by the present work. Given the lower mechanical properties of most bulk-fill materials

  8. Characterization of Low Density Glass Filled Epoxies

    National Research Council Canada - National Science Library

    Quesenberry, Matthew

    2003-01-01

    This report discusses the experimental determination and modeling of several thermophysical and mechanical properties of glass filled epoxy composite systems for potential use as electronic potting compounds...

  9. [Evaluation of cermet fillings in abutment teeth in removable partial prostheses].

    Science.gov (United States)

    Saulic, S; Tihacek-Sojic, Lj

    2001-01-01

    The aim of the study was to describe the clinical process of setting the purpose filling on abutment teeth, after finishing the removable partial dentures. The aim was also to investigate the use of cermet glass-ionomer cement for the purpose filling in the abutment teeth for removable partial dentures, as well as to investigate the surface of the purpose filling. For the clinical evaluation of purpose filling slightly modified criteria according to Ryg's were used in 20 patients with different type of edentulousness. Changes occurring on the surface of purpose filling have been experimentally established by the method of scanning electron microscopy on the half-grown third molars in seven patients. It could be concluded that cement glass-ionomer was not the appropriate material for the purpose fillings in abutment teeth for removable partial dentures.

  10. Inactivation of Aerosolized Biological Agents using Filled Nanocomposite Materials

    Science.gov (United States)

    2013-02-01

    radiation dose absorbed) roentgen shake slug torr (mm Hg, 0 0 C) *The bacquerel (Bq) is the SI unit of radioactivity ; 1 Bq = 1 event/s...setup was made of stainless steel. The setup was assembled and operated inside a class II biosafety cabinet (Model 6TX, Baker Co., Inc., Sanford, ME...system; (ii) Effectiveness of the facility decontamination conducted between the tests; (iii) Inactivation of spores exposed to combustion of strands

  11. Market Assessment and Demonstration of Lignite FBC Ash Flowable Fill Applications

    International Nuclear Information System (INIS)

    Alan E. Bland

    2003-01-01

    Montana-Dakota Utilities (MDU) and Western Research Institute (WRI) have been developing flowable fill materials formulated using ash from the Montana-Dakota Utilities R. M. Heskett Station in Mandan, North Dakota. MDU and WRI have partnered with the U.S. Department of Energy (DOE) and the North Dakota Industrial Commission (NDIC) to further the development of these materials for lignite-fired fluidized-bed combustion (FBC) facilities. The MDU controlled density fill (CDF) appears to be a viable engineering material and environmentally safe. WRI is pursuing the commercialization of the technology under the trademark Ready-Fill(trademark). The project objectives were to: (1) assess the market in the Bismarck-Mandan area; (2) evaluate the geotechnical properties and environmental compatibility; and (3) construct and monitor demonstrations of the various grades of flowable fill products in full-scale demonstrations. The scope of initial phase of work entailed the following: Task I--Assess Market for MDU Flowable Fill Products; Task II--Assess Geotechnical and Environmental Properties of MDU Flowable Fill Products; and Task III--Demonstrate and Monitor MDU Flowable Fill Products in Field-Scale Demonstrations. The results of these testing and demonstration activities proved the following: (1) The market assessment indicated that a market exists in the Bismarck-Mandan area for structural construction applications, such as sub-bases for residential and commercial businesses, and excavatable fill applications, such as gas line and utility trench filling. (2) The cost of the MDU flowable fill product must be lower than the current $35-$45/cubic yard price if it is to become a common construction material. Formulations using MDU ash and lower-cost sand alternatives offer that opportunity. An estimated market of 10,000 cubic yards of MDU flowable fill products could be realized if prices could be made competitive. (3) The geotechnical properties of the MDU ash-based flowable

  12. Market Assessment and Demonstration of Lignite FBC Ash Flowable Fill Applications

    Energy Technology Data Exchange (ETDEWEB)

    Alan E. Bland

    2003-09-30

    Montana-Dakota Utilities (MDU) and Western Research Institute (WRI) have been developing flowable fill materials formulated using ash from the Montana-Dakota Utilities R. M. Heskett Station in Mandan, North Dakota. MDU and WRI have partnered with the U.S. Department of Energy (DOE) and the North Dakota Industrial Commission (NDIC) to further the development of these materials for lignite-fired fluidized-bed combustion (FBC) facilities. The MDU controlled density fill (CDF) appears to be a viable engineering material and environmentally safe. WRI is pursuing the commercialization of the technology under the trademark Ready-Fill{trademark}. The project objectives were to: (1) assess the market in the Bismarck-Mandan area; (2) evaluate the geotechnical properties and environmental compatibility; and (3) construct and monitor demonstrations of the various grades of flowable fill products in full-scale demonstrations. The scope of initial phase of work entailed the following: Task I--Assess Market for MDU Flowable Fill Products; Task II--Assess Geotechnical and Environmental Properties of MDU Flowable Fill Products; and Task III--Demonstrate and Monitor MDU Flowable Fill Products in Field-Scale Demonstrations. The results of these testing and demonstration activities proved the following: (1) The market assessment indicated that a market exists in the Bismarck-Mandan area for structural construction applications, such as sub-bases for residential and commercial businesses, and excavatable fill applications, such as gas line and utility trench filling. (2) The cost of the MDU flowable fill product must be lower than the current $35-$45/cubic yard price if it is to become a common construction material. Formulations using MDU ash and lower-cost sand alternatives offer that opportunity. An estimated market of 10,000 cubic yards of MDU flowable fill products could be realized if prices could be made competitive. (3) The geotechnical properties of the MDU ash-based flowable

  13. 7 CFR 58.730 - Filling containers.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Filling containers. 58.730 Section 58.730 Agriculture... Procedures § 58.730 Filling containers. Hot fluid cheese from the cookers may be held in hotwells or hoppers... shall effectively measure the desired amount of product into the pouch or container in a sanitary manner...

  14. Selective filling of Photonic Crystal Fibres

    DEFF Research Database (Denmark)

    Nielsen, Kristian; Noordegraaf, Danny; Sørensen, Thorkild

    2005-01-01

    A model for calculating the time necessary for filling one or more specific holes in a photonic crystal fibre is made. This model is verified for water, and its enabling potential is illustrated by a polymer application. Selective filling of the core in an air-guide photonic crystal fibre...

  15. Thermal conductivity and stability of nano size carbon black filled PDMS: Fuel cell perspective

    CSIR Research Space (South Africa)

    Chen, H

    2011-01-01

    Full Text Available Carbon black filled Polydimethylsiloxane (PDMS) was considered as a prospective bipolar plate material candidate for a Fuel Cell. In this perspective, thermal conductivity and stability of the composites were investigated. Samples with filler weight...

  16. Impact testing of polymer-filled auxetics using Split Hopkinson Pressure Bar

    Czech Academy of Sciences Publication Activity Database

    Fíla, T.; Zlámal, P.; Jiroušek, O.; Falta, J.; Koudelka_ml., P.; Kytýř, D.; Doktor, T.; Valach, Jaroslav

    2017-01-01

    Roč. 19, č. 10 (2017), č. článku 1700076. ISSN 1438-1656 R&D Projects: GA MŠk(CZ) LO1219 Keywords : bridge decks * filled polymers * filling * honeycomb structures * impact testing * mechanical testing * Poisson ratio * polyurethanes Subject RIV: JJ - Other Materials OBOR OECD: Materials engineering Impact factor: 2.319, year: 2016 http://onlinelibrary.wiley.com/doi/10.1002/adem.201700076/abstract

  17. Biopharmaceutical formulations for pre-filled delivery devices.

    Science.gov (United States)

    Jezek, Jan; Darton, Nicholas J; Derham, Barry K; Royle, Nikki; Simpson, Iain

    2013-06-01

    Pre-filled syringes are becoming an increasingly popular format for delivering biotherapeutics conveniently and cost effectively. The device design and stable liquid formulations required to enable this pre-filled syringe format are technically challenging. In choosing the materials and process conditions to fabricate the syringe unit, their compatibility with the biotherapeutic needs to be carefully assessed. The biothereaputic stability demanded for the production of syringe-compatible low-viscosity liquid solutions requires critical excipient choices to be made. The purpose of this review is to discuss key issues related to the stability aspects of biotherapeutics in pre-filled devices. This includes effects on both physical and chemical stability due to a number of stress conditions the product is subjected to, as well as interactions with the packaging system. Particular attention is paid to the control of stability by formulation. We anticipate that there will be a significant move towards polymer primary packaging for most drugs in the longer term. The timescales for this will depend on a number of factors and hence will be hard to predict. Formulation will play a critical role in developing successful products in the pre-filled syringe format, particularly with the trend towards concentrated biotherapeutics. Development of novel, smart formulation technologies will, therefore, be increasingly important.

  18. Text-Filled Stacked Area Graphs

    DEFF Research Database (Denmark)

    Kraus, Martin

    2011-01-01

    -filled stacked area graphs; i.e., graphs that feature stacked areas that are filled with small-typed text. Since these graphs allow for computing the text layout automatically, it is possible to include large amounts of textual detail with very little effort. We discuss the most important challenges and some...... solutions for the design of text-filled stacked area graphs with the help of an exemplary visualization of the genres, publication years, and titles of a database of several thousand PC games....

  19. Droplet Measurement below Single-Layer Grid Fill

    Directory of Open Access Journals (Sweden)

    Vitkovic Pavol

    2016-01-01

    Full Text Available The main part of the heat transfer in a cooling tower is in a fill zone. This one is consist of a cooling fill. For the cooling tower is used a film fill or grid fill or splash fill in the generally. The grid fill has lower heat transfer performance like film fill usually. But their advantage is high resistance to blockage of the fill. The grid fill is consisted with independent layers made from plastic usually. The layers consist of several bars connected to the different shapes. For experiment was used the rhombus shape. The drops diameter was measured above and below the Grid fill.

  20. Potential of scrap tire rubber as lightweight aggregate in flowable fill.

    Science.gov (United States)

    Pierce, C E; Blackwell, M C

    2003-01-01

    Flowable fill is a self-leveling and self-compacting material that is rapidly gaining acceptance and application in construction, particularly in transportation and utility earthworks. When mixed with concrete sand, standard flowable fill produces a mass density ranging from 1.8 to 2.3 g/cm(3) (115-145 pcf). Scrap tires can be granulated to produce crumb rubber, which has a granular texture and ranges in size from very fine powder to coarse sand-sized particles. Due to its low specific gravity, crumb rubber can be considered a lightweight aggregate. This paper describes an experimental study on replacing sand with crumb rubber in flowable fill to produce a lightweight material. To assess the technical feasibility of using crumb rubber, the fluid- and hardened-state properties of nine flowable fill mixtures were measured. Mixture proportions were varied to investigate the effects of water-to-cement ratio and crumb rubber content on fill properties. Experimental results indicate that crumb rubber can be successfully used to produce a lightweight flowable fill (1.2-1.6 g/cm(3) [73-98 pcf]) with excavatable 28-day compressive strengths ranging from 269 to 1194 kPa (39-173 psi). Using a lightweight fill reduces the applied stress on underlying soils, thereby reducing the potential for bearing capacity failure and minimizing soil settlement. Based on these results, a crumb rubber-based flowable fill can be used in a substantial number of construction applications, such as bridge abutment fills, trench fills, and foundation support fills.

  1. Water sorption and solubility of bulk-fill composites polymerized with a third generation LED LCU

    Directory of Open Access Journals (Sweden)

    Tuğba MİSİLLİ

    2017-10-01

    Full Text Available Abstract The aim of this study was to compare the degree of water sorption and solubility in bulk-fills after curing with a polywave light source. A total of 120 disc-shaped specimens (8 mm diameter; 4 mm depth were prepared from three regular bulk-fill materials (X-tra Fil, Tetric N-Ceram Bulk Fill, SonicFill, and a control material (Filtek Z250, cured in 3 different modes (standard: 1000 mW/cm2-20 s; high power: 1400 mW/cm2-12 s; xtra power: 3200 mW/cm2-6 s using a third generation light-emitting diode light curing unit. Water sorption and solubility levels of the specimens were measured according to the ISO 4049:2009 specification after storing in distilled water for 30 days. Data were analyzed using two-way ANOVA and Tukey’s post-hoc test (p < 0.05. The Z250 sample exposed to high power presented a higher sorption compared to the X-tra Fil and SonicFill samples. In xtra power mode, the values of Z250 and SonicFill were similar to each other and higher compared to those of X-tra Fil. Only SonicFill exhibited significantly different sorption values depending on the curing mode, the highest of which was achieved when using the xtra power mode. The highest solubility values were obtained for SonicFill. No statistically significant differences were found among other groups. No significant correlation was detected between water sorption and solubility. The traditional composite group exhibited a higher water sorption values than the bulk-fills. The reduction in polymerization time significantly increased the sorption of SonicFill. SonicFill showed the highest water solubility value among the composites tested.

  2. Flexible walled container having membrane fitment for use with aseptic filling apparatus

    International Nuclear Information System (INIS)

    Davis, J.C.; Reiss, R.J.; Rica, A.F.

    1984-01-01

    There is disclosed an aseptic flexible walled container having a rigid fitment member cooperative with an aseptic filling apparatus and including a neck, outer flanges surrounding the neck, a frangible membrane and an outer end rim receptive of an hermetically sealed lid. The neck is formed with an internal chamferred seating shoulder for fluid-tight engagement with a fill tube. One outer flange cooperates with clamping jaws of the aseptic filling apparatus for detachably sealing the fitment to a sterilizing chamber and placing it in position for insertion of the filling tube which ruptures the membrane and permits the aseptic introduction of product to the container's interior. The other outer flange is secured to an opening in a wall of the flexible container. The joined fitment and container are presterilized prior to filling. Selected materials for the multi-ply container walls and the fitment permit the container to withstand gamma ray and other sterilization treatment, heat and pressure while maintaining required strength. After the container is aseptically filled, such as with flowable food product, the fill tube is withdrawn and a lid is hermetically sealed onto the rim of the fitment. A heat shield adjacent a container wall surrounds the fitment to protect the container from excessive heat generated by the associated filling apparatus during filling

  3. The screen character of the Whitetiger mountain filling to radioactivity waste disposal

    International Nuclear Information System (INIS)

    Shi Jianfang

    2003-01-01

    Safety disposal of radioactivity waste depends on geology protective screen and artificial protective screen. After disposal site is chosen, the effect of artificial protective screen appears very important. The smashing material of Whitetiger Mountain clay rock is selected as researching object. The method of combining soil mechanics with radiochemistry is adopted on the basis of many experiment of laboratory. The screen effect and mechanism of filling layer to radioactivity nuclide 90 Sr are discussed. Under the circumstance of filling layer composition, control effect of soil body construction to permeability and adsorption of filling protective screen layer are analysed. Synthesis evaluation model of filling protective screen layer is established. It is found that the filling belongs to high-liquids-clay. For filling with diameter equal or smaller than 2 millimeter, when the ρ d equal 1.73 g/cm 3 , the most equitable moving speed of 90 Sr in compaction filling is 4.5 x 10 -5 cm/min, the k equals 2.68 x10 -8 cm/s. For filling with diameter equal or smaller than 5 mm, when the ρ d equal 1.74 g/cm 3 , the most equitable moving speed of 90 Sr in compaction filling is 4.3 x 10 -5 cm/min, the k equals 6.1 x 10 -8 cm/s. (author)

  4. Thermal, spectral, and surface properties of LED light-polymerized bulk fill resin composites.

    Science.gov (United States)

    Pişkin, Mehmet Burçin; Atalı, Pınar Yılmaz; Figen, Aysel Kantürk

    2015-02-01

    The aim of this study was to evaluate the thermal, spectral, and surface properties of four different bulk fill materials – SureFil SDR (SDR, Dentsplay DETREY), QuixFil (QF, Dentsplay DETREY), X-tra base (XB, Voco) X-tra fil (XF, Voco) – polymerized by light-emitting diode (LED). Resin matrix, filler type, size and amount, and photoinitiator types influence the degree of conversion. LED-cured bulk fill composites achieved sufficient polymerization. Scanning electron microscope (SEM) analysis revealed different patterns of surface roughness, depending on the composite material. Bulk fill materials showed surface characteristics similar to those of nanohybrid composites. Based on the thermal analysis results, glass transition (T(g)) and initial degradation (T(i)) temperatures changed depending on the bulk fill resin composites.

  5. PERVAPORATION USING ADSORBENT-FILLED MEMBRANES

    Science.gov (United States)

    Membranes containing selective fillers, such as zeolites and activated carbon, can improve the separation by pervaporation. Applications of adsorbent-filled membranes in pervaporation have been demonstrated by a number of studies. These applications include removal of organic co...

  6. Microtensile bond strength of bulk-fill restorative composites to dentin.

    Science.gov (United States)

    Mandava, Jyothi; Vegesna, Divya-Prasanna; Ravi, Ravichandra; Boddeda, Mohan-Rao; Uppalapati, Lakshman-Varma; Ghazanfaruddin, M D

    2017-08-01

    To facilitate the easier placement of direct resin composite in deeper cavities, bulk fill composites have been introduced. The Mechanical stability of fillings in stress bearing areas restored with bulk-fill resin composites is still open to question, since long term clinical studies are not available so far. Thus, the objective of the study was to evaluate and compare the microtensile bond strength of three bulk-fill restorative composites with a nanohybrid composite. Class I cavities were prepared on sixty extracted mandibular molars. Teeth were divided into 4 groups (n= 15 each) and in group I, the prepared cavities were restored with nanohybrid (Filtek Z250 XT) restorative composite in an incremental manner. In group II, III and IV, the bulk-fill composites (Filtek, Tetric EvoCeram, X-tra fil bulk-fill restoratives) were placed as a 4 mm single increment and light cured. The restored teeth were subjected to thermocycling and bond strength testing was done using instron testing machine. The mode of failure was assessed by scanning electron microscope (SEM). The bond strength values obtained in megapascals (MPa) were subjected to statistical analysis, using SPSS/PC version 20 software.One-way ANOVA was used for groupwise comparison of the bond strength. Tukey's Post Hoc test was used for pairwise comparisons among the groups. The highest mean bond strength was achieved with Filtek bulk-fill restorative showing statistically significant difference with Tetric EvoCeram bulk-fill ( p composites. Adhesive failures are mostly observed with X-tra fil bulk fill composites, whereas mixed failures are more common with other bulk fill composites. Bulk-fill composites exhibited adequate bond strength to dentin and can be considered as restorative material of choice in posterior stress bearing areas. Key words: Bond strength, Bulk-fill restoratives, Configuration factor, Polymerization shrinkage.

  7. Relationships between the climate change and the grain filling of winter wheat

    International Nuclear Information System (INIS)

    Shang, Z.; Jiang, D.

    2016-01-01

    The present study is based on the material in a grain filling rate experiment of winter wheat and hourly weather data organised by Xinghua city of Jiangsu Province. The aims are to objectively evaluate the possible influences of the temperature, precipitation, sunshine at the different time of the same day on the grain filling rate of winter wheat. The grain filling rate evaluation model of climate change is firstly developed, and then, the model calculation results are compared with the observed data. The along the changes of the microclimate, changes of the grain filling rate of winter wheat, which is not same in the gradual, rapid and slow increase stages. The changes in grain filling rate of winter wheat, which were caused by variations of temperature, precipitation and sunshine duration, showed periodic fluctuation. Variation in temperature resulted in 1.36 g d/sup -1/(10a)/sup -1/ of grain filling rate change; variation in precipitation resulted in -1.35 g d/sup -1/. (10a)/sup -1/ of grain filling rate change; and variation in sunshine duration resulted in 0.07 g d/sup -1/ (10a)/sup -1/ of grain filling rate change. Three samples showed a grain filling rate change of 0.08 g d/sup -1/(10a)/sup -1/. These findings indicate that the increase in temperature and sunshine duration caused the elevation of grain filling rate, whereas the increase in precipitation decreased the grain filling rate. Therefore, monitoring and predication capability of Meteorological disasters, such as drought caused by high temperature, should be strengthened to ensure the favourable weather condition and improve the grain filling rate through scientific methods such as artificial precipitation. (author)

  8. Dural sinus filling defect: intrasigmoid encephalocele

    Science.gov (United States)

    Karatag, Ozan; Cosar, Murat; Kizildag, Betul; Sen, Halil Murat

    2013-01-01

    Filling defects of dural venous sinuses are considered to be a challenging problem especially in case of symptomatic patients. Many lesions have to be ruled out such as sinus thrombosis, arachnoid granulations and tumours. Encephalocele into dural sinus is also a rare cause of these filling defects of dural sinuses. Here, we report an extremely rare case with spontaneous occult invagination of temporal brain tissue into the left sigmoid sinus and accompanying cerebellar ectopia. PMID:24311424

  9. 129 Xe-NMR of carbon black filled elastomers

    International Nuclear Information System (INIS)

    Sperling-Ischinsky, K.; Veeman, W.S.

    1999-01-01

    It is shown that 129 Xe-NMR is a powerful tool to investigate carbon black and carbon black filled elastomers. For the carbon black material itself the 129 Xe chemical shift of xenon adsorbed at the surface of carbon black aggregates yields information about the relative average pore size of the carbon black aggregates. The experimental 129 Xe-NMR results of carbon black filled ethylene-propylene-diene (EPDM) can be explained when it is assumed that the xenon atoms in the bound EPDM fraction exchange rapidly on the NMR time scale between a state where they are adsorbed on the carbon black surface and a state in which they are absorbed in the EPDM layer. This would imply that the carbon black aggregates are not completely covered with EPDM chains. (author)

  10. Security of bottle to fill in a high pressure air

    Science.gov (United States)

    Todic, M.; Latinovic, T.; Golubovic-Bugarski, V.; Majstorovic, A.

    2018-01-01

    Charging the bottle of high pressure air isolation devices is performed by a high-pressure compressor. The charging time is in function of the compressor capacity and the intensity of the nominal pressure of the air in the bottle. However, in accident situations this time is long and therefore high-pressure accumulators are used where the filling time of the bottle of isolation apparatus has been drastically reduced. Due to the short filling time of the bottle through the air flow, there is a thermodynamic load of bottle material that could endanger the safety of users and other participants in the area. It is therefore necessary to determine the critical parameters of the rapid charge and their intensity.

  11. A comparative study of bulk-fill composites: degree of conversion, post-gel shrinkage and cytotoxicity

    Directory of Open Access Journals (Sweden)

    Flávia Gonçalves

    2018-03-01

    Full Text Available Abstract: Bulk-fill composites are claimed to be restorative materials used in deep preparations and effectively photoactivated in layers up to 4 mm. The aim of the present study was to evaluate the degree of conversion, post-gel volumetric shrinkage, and cytotoxicity of six bulk-fill and two conventional composites. Degree of conversion was determined by FTIR spectroscopy; post-gel volumetric shrinkage was determined using the strain gauge method; and cytotoxicity in human fibroblasts was evaluated indirectly by the MTT assay. Data were subjected to one-way ANOVA/Tukey's test (α = 0.05. All materials, including bulk-fill and conventional composites, were classified as non-toxic, with cell viability higher than 70%. Bulk-fill composites exhibited volumetric shrinkage similar to or lower (1.4 to 0.4% than that of conventional composites (1.7–2.1%. However, only four of the bulk-fill composites were able to sustain a homogeneous conversion at the 4-mm depth. Despite their non-toxicity and shrinkage similar to that of conventional materials, not all commercial bulk-fill materials were able to maintain a conversion as high as 80% of the superficial layer, at the 4-mm depth, indicating some failure in the bulk-fill design of some commercial brands. Therefore, the use of bulk-fill materials in dental practice is advantageous, but special attention should be given to the selection and correct use of the materials.

  12. Measuring the fill height of sealed cans with a compound pendulum

    International Nuclear Information System (INIS)

    Rinard, P.M.

    1995-06-01

    A compound pendulum has been designed, fabricated, tested, and used to determine the fill height of material in sealed cans. The specific cans that stimulated this work are partially filled with uranium and plutonium oxide. Fill height affects nondestructive assays using fission neutrons, but corrections for various fill heights can be made once the height is known. Heights vary with use as the powder compacts or loosens, so it is necessary to determine the height at the time of the neutron measurement. The pendulum is small and readily portable so it can be taken to the location of the neutron measurement. Tests with open cans filled with sand to various known heights had accuracies generally within 3%. Factors that can affect the accuracy are examined and discussed. Experience in using the pendulum on sealed cans is related

  13. Assessment of periapical health, quality of root canal filling, and ...

    African Journals Online (AJOL)

    Sixty three teeth were found to have short root canal fillings, whereas 74 teeth had adequate root canal fillings, and the remaining 10 teeth had over extended root canal filling. A significant correlation was observed between the length of root filling and apical periodontitis (P = 0,023). Inadequately dense root canal filling was ...

  14. Soil and minespoil fill as media for renovation of nitrogen and phosphorus in domestic wastewater

    International Nuclear Information System (INIS)

    Peterson, C.E.; Reneau, R.B. Jr.; Hagedorn, C.

    1998-01-01

    Development of US Appalachian coal mining regions has been hampered by lack of domestic waste disposal technologies suited to fills. The suitability of on-site wastewater treatment and disposal systems (OSWTDS) in fill material is uncertain due to the effects of surface mining on soil physical properties. This research evaluated the potential for renovation of N and P present in domestic wastewater by fills from mining operations. N and P were chosen because of their potential adverse environmental impacts. Soil-fill (a mixture of Jefferson, fine-loamy, siliceous, mesic Typic Hapludult and Muskingom, fine-loamy, mixed, mesic Typic Dystrochrept soils) and minespoil (spoil)-fill (blasted rock material associated with the Taggart Marker and Low Splint Bench coal seams of the Upper Middle Wise Formation) were used. Septic tank effluent (STE) and sand filter effluent (SFE) were applied to spoil-fill columns at four loading rates and spoil-fill columns at one loading rate for a period of 20 wk. Renovation of wastewater was assessed by determining the concentration of N and P present in column leachate. Reduction of inorganic N(NO 3 - + NH 4 + ), based on N/Cl ratios ranged from 14.9 to 32.1% after the varying application rates of STE and SFE passed through the soil columns. However, leachate NO 3 - -N concentrations were still above the 10 mg -1 drinking water standard. The quantity of P emerging from the spoil-fill columns (3.0 mg PL -1 ) was higher than anticipated and may be related to the indigenous P present in the minespoil. Sorption of P in the spoil-fill column decreased with increased STE and SFE application (reduction ranged from 99.1 to 74.4%). Results from this study indicate that there is potential for renovating wastewater in OSWTDS in selected soil-fill areas in reclaimed minelands. 33 refs., 2 figs., 4 tabs

  15. NSLS-II filling pattern measurement

    International Nuclear Information System (INIS)

    Yong Hu; Dalesio, L.B.; Kiman Ha; Pinayev, I.

    2012-01-01

    Multi-bunch injection will be deployed at NSLS-II. High bandwidth diagnostic beam monitors with high speed digitizers are used to measure bunch-by-bunch charge variation. In order to minimize intensity-correlated orbit oscillations due to uneven bunch patterns, we need to measure the filling pattern (also named bunch pattern or bunch structure). This paper focuses on filling pattern measurements: how to measure bunch structure and make this information available in EPICS-based control system. This measurement requires combination of 3 types of beam monitors (Wall Current Monitor, Fast Current Transformer and Beam Position Monitor), data acquisition and controls (fast digitizer, EPICS software, etc.) and Event Timing system. High-bandwidth filling pattern monitor requires high-speed digitizer to sample its analog output signal. The evaluation results of commercial fast digitizer Agilent Acqiris and high bandwidth detector Bergoz FCT are presented. We have also tested the algorithm software for filling pattern measurement as well as the interface to event timing system. It appears that filling pattern measurement system is well understood and the tests for control hardware and software have given good results

  16. Strength of biodegradable polypropylene tapes filled with a modified starch

    Science.gov (United States)

    Vinidiktova, N. S.; Ermolovich, O. A.; Goldade, V. A.; Pinchuk, L. S.

    2006-05-01

    The possibility of creating composite materials with high deformation and strength characteristics based on polypropylene (PP) and a natural polysaccharide in the form of a modified starch (MS) has been studied. The modified starch is shown to interact chemically with functional groups of PP, thereby positively affecting the physicomechanical properties, structure, and water absorption properties of films and oriented flat fibers based on starch-filled PP. The strength characteristics of both oriented and unoriented composites are 1.5-2.0 times as high as those of the initial PP. The water absorption ability of the materials varies symbatically with content of MS, which points to the dominant contribution of interactions at the PP-MS interface. The introduction of MS into synthetic polymers offers a possibility of producing new ecologically safe materials with high strength characteristics.

  17. One-dimensional Gromov minimal filling problem

    International Nuclear Information System (INIS)

    Ivanov, Alexandr O; Tuzhilin, Alexey A

    2012-01-01

    The paper is devoted to a new branch in the theory of one-dimensional variational problems with branching extremals, the investigation of one-dimensional minimal fillings introduced by the authors. On the one hand, this problem is a one-dimensional version of a generalization of Gromov's minimal fillings problem to the case of stratified manifolds. On the other hand, this problem is interesting in itself and also can be considered as a generalization of another classical problem, the Steiner problem on the construction of a shortest network connecting a given set of terminals. Besides the statement of the problem, we discuss several properties of the minimal fillings and state several conjectures. Bibliography: 38 titles.

  18. Development and Substantiation of Parameters of Environmentally Friendly Technology for Filling the Vertical Mine Workings with Autoclaved Slag-Concrete

    Directory of Open Access Journals (Sweden)

    Uglyanitca Andrey

    2017-01-01

    Full Text Available The environmentally friendly technology for filling the vertical mine workings with autoclaved slag-concrete, prefabricated on the surface of the mine is presented in the article; the optimal parameters of filling technology are proposed. The developed technology for filling the abandoned vertical mine workings allows ensuring the environmental safety of the territories adjacent to the abandoned mine, utilizing slag dumps and providing the possibility of shaft recovery, if necessary, with minimal labor and material costs.

  19. Burrowing inhibition by fine textured beach fill: Implications for recovery of beach ecosystems

    Science.gov (United States)

    Viola, Sloane M.; Hubbard, David M.; Dugan, Jenifer E.; Schooler, Nicholas K.

    2014-10-01

    Beach nourishment is often considered the most environmentally sound method of maintaining eroding shorelines. However, the ecological consequences are poorly understood. Fill activities cause intense disturbance and high mortality and have the potential to alter the diversity, abundance, and distribution of intertidal macroinvertebrates for months to years. Ecological recovery following fill activities depends on successful recolonization and recruitment of the entire sandy intertidal community. The use of incompatible sediments as fill material can strongly affect ecosystem recovery. We hypothesized that burrowing inhibition of intertidal animals by incompatible fine fill sediments contributes to ecological impacts and limits recovery in beach ecosystems. We experimentally investigated the influence of intertidal zone and burrowing mode on responses of beach invertebrates to altered sediment texture (28-38% fines), and ultimately the potential for colonization and recovery of beaches disturbed by beach filling. Using experimental trials in fill material and natural beach sand, we found that the mismatched fine fill sediments significantly inhibited burrowing of characteristic species from all intertidal zones, including sand crabs, clams, polychaetes, isopods, and talitrid amphipods. Burrowing performance of all five species we tested was consistently reduced in the fill material and burrowing was completely inhibited for several species. The threshold for burrowing inhibition by fine sediment content in middle and lower beach macroinvertebrates varied by species, with highest sensitivity for the polychaete (4% fines, below the USA regulatory limit of 10% fines), followed by sand crabs and clams (20% fines). These results suggest broader investigation of thresholds for burrowing inhibition in fine fill material is needed for beach animals. Burrowing inhibition caused by mismatched fill sediments exposes beach macroinvertebrates to stresses, which could depress

  20. Toughening Mechanisms in Silica-Filled Epoxy Nanocomposites

    Science.gov (United States)

    Patel, Binay S.

    Epoxies are widely used as underfill resins throughout the microelectronics industry to mechanically couple and protect various components of flip-chip assemblies. Generally rigid materials largely surround underfill resins. Improving the mechanical and thermal properties of epoxy resins to better match those of their rigid counterparts can help extend the service lifetime of flip-chip assemblies. Recently, researchers have demonstrated that silica nanoparticles are effective toughening agents for lightly-crosslinked epoxies. Improvements in the fracture toughness of silica-filled epoxy nanocomposites have primarily been attributed to two toughening mechanisms: particle debonding with subsequent void growth and matrix shear banding. Various attempts have been made to model the contribution of these toughening mechanisms to the overall fracture energy observed in silica-filled epoxy nanocomposites. However, disparities still exist between experimental and modeled fracture energy results. In this dissertation, the thermal, rheological and mechanical behavior of eight different types of silica-filled epoxy nanocomposites was investigated. Each nanocomposite consisted of up to 10 vol% of silica nanoparticles with particle sizes ranging from 20 nm to 200 nm, with a variety of surface treatments and particle structures. Fractographical analysis was conducted with new experimental approaches in order to accurately identify morphological evidence for each proposed toughening mechanism. Overall, three major insights into the fracture behavior of real world silica-filled epoxy nanocomposites were established. First, microcracking was observed as an essential toughening mechanism in silica-filled epoxy nanocomposites. Microcracking was observed on the surface and subsurface of fractured samples in each type of silica-filled epoxy nanocomposite. The additional toughening contribution of microcracking to overall fracture energy yielded excellent agreement between experimental

  1. Posterior bulk-filled resin composite restorations.

    DEFF Research Database (Denmark)

    van Dijken, Jan WV; Pallesen, Ulla

    2016-01-01

    up to 4mm as needed to fill the cavity 2mm short of the occlusal cavosurface. The occlusal part was completed with the nano-hybrid resin composite (Ceram X mono+). In the other cavity, the resin composite-only (Ceram X mono+) was placed in 2mm increments. The restorations were evaluated using...... Class II, 4 SDR-CeramX mono+ and 6 CeramXmono+-only restorations. The main reasons for failurewere tooth fracture (6) and secondary caries (4). The annual failure rate (AFR) for all restorations (Class I and II) was for the bulk-filled-1.1% and for the resin composite-only restorations 1...

  2. Application of mathematical planning in production of filled emulsion rubbers

    Science.gov (United States)

    Pugacheva, I. N.; Molokanova, L. V.; Popova, L. V.; Repin, P. S.

    2018-05-01

    The applicability of mathematical planning of experiment in the field of chemistry and chemical engineering, in particular in the industrial production of synthetic rubbers, is considered in the article. Possibility of using secondary material resources, which are waste products of light industry, in the production of elastomeric compositions is studied. The method of obtaining a powdered cellulose additive from wastes containing cellulose fiber is described. The best way of introducing the obtained additive into elastomeric compositions based on the emulsion rubber is established. Optimal conditions for obtaining filled emulsion rubber with the help of a powdered cellulose additive were established basing on the mathematical planning of experiment.

  3. The structure of filled skutterudites and the local vibration behavior of the filling atom

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xiaojuan [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Dongguan Institute of Neutron Science, Dongguan 523808 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Zong, Peng-an [State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Chen, Xihong [Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Tao, Juzhou, E-mail: taoj@ihep.ac.cn [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Dongguan Institute of Neutron Science, Dongguan 523808 (China); Lin, He, E-mail: linhe@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Science, Shanghai 201204 (China)

    2017-02-15

    Both of atomic pair distribution function (PDF) and extended x-ray absorption fine structure (EXAFS) experiments have been carried out on unfilled and Yb-filled skutterudites Yb{sub x}Co{sub 4}Sb{sub 12} (x=0, 0.15, 0.2 and 0.25) samples. The structure refinements on PDF data confirm the large amplitude vibration of Yb atom and the dependence of Yb vibration amplitude on the filling content. Temperature dependent EXAFS experiment on filled skutterudites have been carried out at Yb L{sub Ⅲ}-edge in order to explore the local vibration behavior of filled atom. EXAFS experiments show that the Einstein temperature of the filled atom is very low (70.9 K) which agrees with the rattling behavior.

  4. Application of isotope tracer technique on the study of the filling and release behavior of carbon nanotubes

    International Nuclear Information System (INIS)

    Wu Shengwei; Guo Jinxue; Li Yan; Li Yulan; Li Wenxin; Liu Shiyuan

    2004-01-01

    The behaviors of washing and release of 110 Ag m -AgNO 3 from carbon nanotubes (CNTs), following soak of opened CNTs in 110 Ag m -AgNO 3 solutions are investigated with the isotope tracer technique. The filled CNTs samples are characterized by HREM, SEM, XRD and EDS. The amount of filled materials is also estimated by the isotope tracer technique. It shows that there are silver materials filled in the CNTs and would not release from the cavities. The results indicate that radioactive tracer is an effective and powerful technique to be applied into study of filling and release behaviors of CNTs as well as estimating the amount of filled materials. (authors)

  5. Form Filling with Self-Compacting Concrete

    DEFF Research Database (Denmark)

    Thrane, Lars Nyholm

    2002-01-01

    This paper describes a newly started Ph.D. project with the aim of simulating the form filling ability of Self-Compacting Concrete (SCC) taking into account the form geometry, reinforcement configuration, casting technique, and the rheological properties of the concrete. Comparative studies...

  6. Stock keeping unit fill rate specification

    NARCIS (Netherlands)

    Teunter, R. H.; Syntetos, A. A.; Babai, M. Z.

    2017-01-01

    The fill rate is the most widely applied service level measure in industry and yet there is minimal advice available on how it should be differentiated on an individual Stock Keeping Unit (SKU) basis given that there is an overall system target service level. The typical approach utilized in

  7. New Skeletal-Space-Filling Models

    Science.gov (United States)

    Clarke, Frank H.

    1977-01-01

    Describes plastic, skeletal molecular models that are color-coded and can illustrate both the conformation and overall shape of small molecules. They can also be converted to space-filling counterparts by the additions of color-coded polystyrene spheres. (MLH)

  8. Safety distances for hydrogen filling stations

    NARCIS (Netherlands)

    Matthijsen, A J C M; Kooi, E S

    2006-01-01

    In the context of spatial planning the Dutch Ministry of Housing, Spatial Planning and the Environment asked the Centre for External Safety of the National Institute for Public Health and the Environment (RIVM) to advice on safe distances pertaining to hydrogen filling stations. The RIVM made use of

  9. Banach spaces that realize minimal fillings

    International Nuclear Information System (INIS)

    Bednov, B. B.; Borodin, P. A.

    2014-01-01

    It is proved that a real Banach space realizes minimal fillings for all its finite subsets (a shortest network spanning a fixed finite subset always exists and has the minimum possible length) if and only if it is a predual of L 1 . The spaces L 1 are characterized in terms of Steiner points (medians). Bibliography: 25 titles. (paper)

  10. INS gas-filled recoil isotope separator

    International Nuclear Information System (INIS)

    Miyatake, M.; Nomura, T.; Kawakami, H.

    1986-09-01

    The characteristics and performance of a small sized gas-filled recoil isotope separator recently made at INS are described. The total efficiency and the ΔBρ/Bρ values have been measured using low velocity 16 O, 40 Ar and 68 As ions and found to be 10 and 5 %, respectively. The Z-dependence of the mean charge is discussed. (author)

  11. Stability of fruit bases and chocolate fillings

    Directory of Open Access Journals (Sweden)

    Joice Natali Miquelim

    2011-03-01

    Full Text Available Syrups with high sugar content and dehydrated fruits in its composition can be added to chocolate fillings to reduce the need of artificial flavor and dyes attributing a natural appeal to the product. Fruit bases were produced with lyophilized strawberry, passion fruit, and sliced orange peel. Rheological dynamic oscillatory tests were applied to determine the products stability and tendency of shelf life. Values of G´ G´´ were found for orange flavor during the 90 days of storage. It was observed that shear stress values did not vary significantly suggesting product stability during the studied period. For all fillings, it was found a behavior similar to the fruit base indicating that it has great influence on the filling behavior and its stability. The use of a sugar matrix in fillings provided good shelf life for the fruit base, which could be kept under room temperature conditions for a period as long as one year. The good stability and storage conditions allow the use of fruit base for handmade products as well as for industrialized products.

  12. Full-waveform inversion: Filling the gaps

    KAUST Repository

    Beydoun, Wafik B.; Alkhalifah, Tariq Ali

    2015-01-01

    After receiving an outstanding response to its inaugural workshop in 2013, SEG once again achieved great success with its 2015 SEG Middle East Workshop, “Full-waveform inversion: Filling the gaps,” which took place 30 March–1 April 2015 in Abu Dhabi

  13. A mathematical model for lake ontogeny in terms of filling with sediments and macrophyte vegetation

    International Nuclear Information System (INIS)

    Brydsten, Lars

    2004-05-01

    A mathematical model for simulation of lake basin filling processes in areas with positive shore displacement was constructed. The model was calibrated using sediment and catchments data from eight existing lake basins situated in the northern coastal area of the province of Uppland, Sweden. The lake basin filling processes were separated into three phases: basin filling with wave-washed material (silt, silty sand or sand), filling with fine-grained material during the shallow gulf and lake stages, respectively, and filling with vegetation during the lake stage. The basin filling rates for wave-washed material were generally low but varied considerably both between and within lakes. The mean basin filling rate of wave-washed material was 4.1%. The volume of inorganic sediments produced, and basin filling rates during the shallow gulf and lake phases were determined for all the eight lakes. The relationship between basin filling rate and parameters describing the catchments, the former postglacial basins and the lakes, respectively, was determined using multiple regression analysis. The basin filling rate with inorganic sediments was best described by parameters related to former postglacial basin morphometry and current lake morphometry, e.g. basin volume, lake volume, and lake area. The goodness of fit turned out to be 0.99 for a simple regression with basin volume as the sole independent variable. The basin filling with vegetation (Phragmites australis followed by Sphagnum spp.) was treated as a 2-dimensional process. A dataset with 84 bogs was selected from a digital soil map. The ages of the bogs were calculated using a digital elevation map and an equation for shore displacement. The choke-up rate was then calculated by dividing the area of the bogs with their age. A strong exponential relationship exists between areas of the bogs and choke-up rat, and this relationship was then used in the model. The resulting model starts by filling the former coastal basin

  14. A mathematical model for lake ontogeny in terms of filling with sediments and macrophyte vegetation

    Energy Technology Data Exchange (ETDEWEB)

    Brydsten, Lars [Umeaa Univ. (Sweden). Dept. of Biology and Environmental Science

    2004-05-01

    A mathematical model for simulation of lake basin filling processes in areas with positive shore displacement was constructed. The model was calibrated using sediment and catchments data from eight existing lake basins situated in the northern coastal area of the province of Uppland, Sweden. The lake basin filling processes were separated into three phases: basin filling with wave-washed material (silt, silty sand or sand), filling with fine-grained material during the shallow gulf and lake stages, respectively, and filling with vegetation during the lake stage. The basin filling rates for wave-washed material were generally low but varied considerably both between and within lakes. The mean basin filling rate of wave-washed material was 4.1%. The volume of inorganic sediments produced, and basin filling rates during the shallow gulf and lake phases were determined for all the eight lakes. The relationship between basin filling rate and parameters describing the catchments, the former postglacial basins and the lakes, respectively, was determined using multiple regression analysis. The basin filling rate with inorganic sediments was best described by parameters related to former postglacial basin morphometry and current lake morphometry, e.g. basin volume, lake volume, and lake area. The goodness of fit turned out to be 0.99 for a simple regression with basin volume as the sole independent variable. The basin filling with vegetation (Phragmites australis followed by Sphagnum spp.) was treated as a 2-dimensional process. A dataset with 84 bogs was selected from a digital soil map. The ages of the bogs were calculated using a digital elevation map and an equation for shore displacement. The choke-up rate was then calculated by dividing the area of the bogs with their age. A strong exponential relationship exists between areas of the bogs and choke-up rat, and this relationship was then used in the model. The resulting model starts by filling the former coastal basin

  15. Study of a low-dose capsule filling process by dynamic and static tests for advanced process understanding.

    Science.gov (United States)

    Stranzinger, S; Faulhammer, E; Scheibelhofer, O; Calzolari, V; Biserni, S; Paudel, A; Khinast, J G

    2018-04-05

    Precise filling of capsules with doses in the mg-range requires a good understanding of the filling process. Therefore, we investigated the various process steps of the filling process by dynamic and static mode tests. Dynamic tests refer to filling of capsules in a regular laboratory dosator filling machine. Static tests were conducted using a novel filling system developed by us. Three grades of lactose excipients were filled into size 3 capsules with different dosing chamber lengths, nozzle diameters and powder bed heights, and, in the dynamic mode, with two filling speeds (500, 3000 caps/h). The influence of the gap at the bottom of the powder container on the fill weight and variability was assessed. Different gaps resulted in a change in fill weight in all materials, although in different ways. In all cases, the fill weight of highly cohesive Lactohale 220 increased when decreasing the gap. Furthermore, experiments with the stand-alone static test tool indicated that this very challenging powder could successfully be filled without any pre-compression in the range of 5 mg-20 mg with acceptable RSDs. This finding is of great importance since for very fine lactose powders high compression ratios (dosing-chamber-length-to-powder-bed height compression ratios) may result in jamming of the piston. Moreover, it shows that the static mode setup is suitable for studying fill weight and variability. Since cohesive powders, such as Lactohale 220, are hard to fill, we investigated the impact of vibration on the process. Interestingly, we found no correlation between the reported fill weight changes in dynamic mode at 3000 cph and static mode using similar vibration. However, we could show that vibrations during sampling in the static mode dramatically reduced fill weight variability. Overall, our results indicate that by fine-tuning instrumental settings even very challenging powders can be filled with a low-dose dosator capsule filling machine. This study is a

  16. Multiscale Modeling of Dewetting Damage in Highly Filled Particulate Composites

    Science.gov (United States)

    Geubelle, P. H.; Inglis, H. M.; Kramer, J. D.; Patel, J. J.; Kumar, N. C.; Tan, H.

    2008-02-01

    Particle debonding or dewetting constitutes one of the key damage processes in highly filled particulate composites such as solid propellant and other energetic materials. To analyze this failure process, we have developed a multiscale finite element framework that combines, at the microscale, a nonlinear description of the binder response with a cohesive model of the damage process taking place in a representative periodic unit cell (PUC). To relate micro-scale damage to the macroscopic constitutive response of the material, we employ the mathematical theory of homogenization (MTH). After a description of the numerical scheme, we present the results of the damage response of a highly filled particulate composite subjected to a uniaxial macroscopic strain, and show the direct correlation between the complex damage processes taking place in the PUC and the nonlinear macroscopic constitutive response. We also present a detailed study of the PUC size and a comparison between the finite element MTH-based study and a micromechanics model of the dewetting process.

  17. The order and volume fill rates in inventory control systems

    DEFF Research Database (Denmark)

    Thorstenson, Anders; Larsen, Christian

    2011-01-01

    This paper differentiates between an order (line) fill rate and a volume fill rate and specifies their performance for different inventory control systems. When the focus is on filling complete customer orders rather than total quantities the order fill rate would be the preferred service level m...

  18. Iterative and variational homogenization methods for filled elastomers

    Science.gov (United States)

    Goudarzi, Taha

    Elastomeric composites have increasingly proved invaluable in commercial technological applications due to their unique mechanical properties, especially their ability to undergo large reversible deformation in response to a variety of stimuli (e.g., mechanical forces, electric and magnetic fields, changes in temperature). Modern advances in organic materials science have revealed that elastomeric composites hold also tremendous potential to enable new high-end technologies, especially as the next generation of sensors and actuators featured by their low cost together with their biocompatibility, and processability into arbitrary shapes. This potential calls for an in-depth investigation of the macroscopic mechanical/physical behavior of elastomeric composites directly in terms of their microscopic behavior with the objective of creating the knowledge base needed to guide their bottom-up design. The purpose of this thesis is to generate a mathematical framework to describe, explain, and predict the macroscopic nonlinear elastic behavior of filled elastomers, arguably the most prominent class of elastomeric composites, directly in terms of the behavior of their constituents --- i.e., the elastomeric matrix and the filler particles --- and their microstructure --- i.e., the content, size, shape, and spatial distribution of the filler particles. This will be accomplished via a combination of novel iterative and variational homogenization techniques capable of accounting for interphasial phenomena and finite deformations. Exact and approximate analytical solutions for the fundamental nonlinear elastic response of dilute suspensions of rigid spherical particles (either firmly bonded or bonded through finite size interphases) in Gaussian rubber are first generated. These results are in turn utilized to construct approximate solutions for the nonlinear elastic response of non-Gaussian elastomers filled with a random distribution of rigid particles (again, either firmly

  19. Characterization of subvisible particle formation during the filling pump operation of a monoclonal antibody solution.

    Science.gov (United States)

    Nayak, Arpan; Colandene, James; Bradford, Victor; Perkins, Melissa

    2011-10-01

    Characterization and control of aggregate and subvisible particle formation during fill-finish process steps are important for biopharmaceutical products. The filling step is of key importance as there is no further filtration of the drug product beyond sterile filtration. Filling processes can impact product quality by introducing physical stresses such as shear, friction, and cavitation. Other detrimental factors include temperature generated in the process of filling, foaming, and contact with filling system materials, including processing aids such as silicone oil. Certain pumps may shed extrinsic particles that may lead to heterogeneous nucleation-induced aggregation. In this work, microflow imaging, size-exclusion chromatography (SEC), and turbidimetry were utilized to quantify subvisible particles, aggregation, and opalescence, respectively. The filling process was performed using several commonly used filling systems, including rotary piston pump, rolling diaphragm pump, peristaltic pump, and time-pressure filler. The rolling diaphragm pump, peristaltic pump, and time-pressure filler generated notably less protein subvisible particles than the rotary piston pump, although no change in aggregate content by SEC was observed by any pump. An extreme increase in subvisible particles was also reflected in an increase in turbidity. Copyright © 2011 Wiley-Liss, Inc.

  20. Hugoniot-based equations of state for two filled EPDM rubbers

    Science.gov (United States)

    Pacheco, Adam; Dattelbaum, Dana; Orler, E.; Gustavsen, R.

    2013-06-01

    The shock response of silica filled and Kevlar filled ethylene-propylene-diene (EPDM) rubbers was studied using gas gun-driven plate impact experiments. Both materials are proprietary formulations made by Kirkhill-TA, Brea CA USA, and are used for ablative internal rocket motor insulation. Two types of experiments were performed. In the first, the filled-EPDM sample was mounted on the front of the projectile and impacted a Lithium Fluoride (LiF) window. The Hugoniot state was determined from the measured projectile velocity, the EPDM/LiF interface velocity (measured using VISAR) and impedance matching to LiF. In the second type of experiment, electromagnetic particle velocity gauges were embedded between layers of filled-EPDM. These provided in situ particle velocity and shock velocity measurements. Experiments covered a pressure range of 0.34 - 14 GPa. Hugoniot-based equations of state were obtained for both materials, and will be compared to those of other filled elastomers such as silica-filled polydimethylsiloxane and adiprene. Work performed while at Los Alamos National Laboratory.

  1. Flammability of Gas-Filled Polymers

    Directory of Open Access Journals (Sweden)

    Ushkov Valentin Anatol'evich

    2017-09-01

    Full Text Available The regularities of flame propagation on the horizontal surface of gas-filled polymers are considered depending on the concentration of oxygen in the oxidizer flow. The values of the coefficients in the expression describing relationship between the rate of flame propagation on the surface of foams and oxygen concentration are obtained. It was shown that with the mass content of reactive organophosphorus compounds reaching 4.0...5.9%, non-smoldering resole foam plastics with high performance characteristics are obtained. It was found that in order to obtain moderately combustible polyurethane foams based on oxyethylated phosphorus-containing polyols, the phosphorus concentration should not exceed 3 % of mass. To obtain flame-retardant urea-formaldehyde foam cellular plastics, the concentration of phosphorus should not exceed 0.3 % of mass. Physical-mechanical properties and flammability indices of developed gas-filled polymers based on reactive oligomers are presented.

  2. Form Filling with Self-Compacting Concrete

    DEFF Research Database (Denmark)

    Thrane, Lars Nyholm

    2007-01-01

    to the prospects of improving the structural quality, working environment, productivity, and architectural appearance. However, especially in vertical applications there is a great unused potential. Controlling the casting process is important in many different industries such as the metal, plastic, and food...... the framework of Computational Fluid Dynamics (CFD). CFD is applied to simulate the homogeneous form filling characteristics, i.e. the form filling ability and flow patterns, taking into account the rheological properties and casting technique. It is assumed that the rheological properties of SCC follow...... dimensions. For the heterogeneous flow phenomena, this project focusses on the assessment of blocking, which is of special interest in relation to high quality and complicated structures with a dense reinforcement configuration. A phenomenological micro-mechanical model has been developed, which introduces...

  3. Rainwater drained through fully filled pipes

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, B; Koestel, P

    1989-02-01

    The conventional rainwater drainage system according to DIN 1986 always seems to be a point of problemacy in the building services as far as the occupancy of installation shafts and ducts is at stake. The excavation work and the necessary gravity lines are considered to be expensive. The consideration of the necessary slope complicates the installation additionally. Basing on those considerations, the raindraining system with fully filled pipes has been developed. DIN 1986, edition June 1988, part 1, point 6.1.1 allows to install rainwater pipes operated as planned, fully filled without slope. An enterprise specialised in building services investigated all system laws because only by a hydraulically exact balance, the function of the rainwater drainage system operated by negative and positive pressure can be insured. The results of those investigations are integrated in a computer program developed for this purpose.

  4. Optical properties study of nano-composite filled D shape photonic crystal fibre

    Science.gov (United States)

    Udaiyakumar, R.; Mohamed Junaid, K. A.; Janani, T.; Maheswar, R.; Yupapin, P.; Amiri, I. S.

    2018-06-01

    With the nano-composite materials gaining momentum in the optical field, a new nano-composite filled D shape Photonic Crystal Fiber (PCF) is designed and the various optical properties are investigated with help of Finite Element Method. In the proposed structure the D-shape PCF is made up of silica with embedded silver nanoparticles and air holes are distributed along the fibre. The designed fibre shows various optical properties such as dispersion, birefringence, beat length and loss with respect to wavelength and compared with different filling factor like 0.1, 0.3 and 0.5. From our estimation and comparative analysis, it has been proved that the fibre loss has been decreased with increasing filling factor. Further this also showed flat dispersion at maximum filling factor.

  5. Optical properties study of nano-composite filled D shape photonic crystal fibre

    Directory of Open Access Journals (Sweden)

    R. Udaiyakumar

    2018-06-01

    Full Text Available With the nano-composite materials gaining momentum in the optical field, a new nano-composite filled D shape Photonic Crystal Fiber (PCF is designed and the various optical properties are investigated with help of Finite Element Method. In the proposed structure the D-shape PCF is made up of silica with embedded silver nanoparticles and air holes are distributed along the fibre. The designed fibre shows various optical properties such as dispersion, birefringence, beat length and loss with respect to wavelength and compared with different filling factor like 0.1, 0.3 and 0.5. From our estimation and comparative analysis, it has been proved that the fibre loss has been decreased with increasing filling factor. Further this also showed flat dispersion at maximum filling factor. Keywords: Nanoparticles, Nano-composite, Dispersion, Birefringence, Beat length

  6. Design compliance matrix waste sample container filling system for nested, fixed-depth sampling system

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    This design compliance matrix document provides specific design related functional characteristics, constraints, and requirements for the container filling system that is part of the nested, fixed-depth sampling system. This document addresses performance, external interfaces, ALARA, Authorization Basis, environmental and design code requirements for the container filling system. The container filling system will interface with the waste stream from the fluidic pumping channels of the nested, fixed-depth sampling system and will fill containers with waste that meet the Resource Conservation and Recovery Act (RCRA) criteria for waste that contains volatile and semi-volatile organic materials. The specifications for the nested, fixed-depth sampling system are described in a Level 2 Specification document (HNF-3483, Rev. 1). The basis for this design compliance matrix document is the Tank Waste Remediation System (TWRS) desk instructions for design Compliance matrix documents (PI-CP-008-00, Rev. 0)

  7. Air filled porosity in composting processes

    Energy Technology Data Exchange (ETDEWEB)

    Ruggieri, L.; Gea, T.; Artola, A.; Sanchez, A.

    2009-07-01

    As it is widely known, the composting process consists in the aerobic decomposition of the biodegradable organic matter present in different types of solid wastes. Water and oxygen are necessary for the biological activity of microorganisms involved in the composting process and their availability is directly related to the total and the air filled porosity (AFP). Maintaining adequate AFP level satisfies the oxygen content requirement to achieve the desired composting conditions and thus, tho enhance biological activity. (Author)

  8. Moon - 'Ghost' craters formed during Mare filling.

    Science.gov (United States)

    Cruikshank, D. P.; Hartmann, W. K.; Wood, C. A.

    1973-01-01

    This paper discusses formation of 'pathological' cases of crater morphology due to interaction of craters with molten lavas. Terrestrial observations of such a process are discussed. In lunar maria, a number of small impact craters (D less than 10 km) may have been covered by thin layers of fluid lavas, or formed in molten lava. Some specific lunar examples are discussed, including unusual shallow rings resembling experimental craters deformed by isostatic filling.

  9. Mobile myelographic filling defects: Spinal cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Savoiardo, M.; Cimino, C.; Passerini, A.; La Mantia, L.

    1986-03-01

    Cysticercosis usually affects the brain and is easily demonstrated by CT. Spinal cysticercosis is much rarer and is usually diagnosed only at surgery. Myelographic demonstration of multiple rounded filling defects, some of which were mobile, allowed diagnosis of spinal extramedullary cysticercosis in an unsuspected case. The literature on spinal cysticercosis is briefly reviewed. Diagnosis is important in view of the recent development of medical treatment.

  10. The partially filled viscous ring damper.

    Science.gov (United States)

    Alfriend, K. T.

    1973-01-01

    The problem of a spinning satellite with a partially filled viscous ring damper is investigated. It is shown that there are two distinct modes of motion, the nutation-synchronous mode and spin-synchronous mode. From an approximate solution of the equations of motion a time constant is obtained for each mode. From a consideration of the fluid dynamics several methods are developed for determining the damping constant.

  11. Pulse formation of gas-filled counter

    International Nuclear Information System (INIS)

    Iwatani, Kazuo; Teshima, Kazunori; Shizuma, Kiyoshi; Hasai, Hiromi

    1991-01-01

    The pulse formation of gas-filled counter has been calculated by simple models for the proportional and self-quenching streamer (SQS) modes. Calculated pulse shapes of counter output have accurately reproduced the observed ones for both modes. As a result, it is shown that the special density distribution of ion pairs in a streamer can be estimated with the rising part of observed pulse shape, using the model. (author)

  12. Full-waveform inversion: Filling the gaps

    KAUST Repository

    Beydoun, Wafik B.

    2015-09-01

    After receiving an outstanding response to its inaugural workshop in 2013, SEG once again achieved great success with its 2015 SEG Middle East Workshop, “Full-waveform inversion: Filling the gaps,” which took place 30 March–1 April 2015 in Abu Dhabi, UAE. The workshop was organized by SEG, and its partner sponsors were Saudi Aramco (gold sponsor), ExxonMobil, and CGG. Read More: http://library.seg.org/doi/10.1190/tle34091106.1

  13. Air filled porosity in composting processes

    International Nuclear Information System (INIS)

    Ruggieri, L.; Gea, T.; Artola, A.; Sanchez, A.

    2009-01-01

    As it is widely known, the composting process consists in the aerobic decomposition of the biodegradable organic matter present in different types of solid wastes. Water and oxygen are necessary for the biological activity of microorganisms involved in the composting process and their availability is directly related to the total and the air filled porosity (AFP). Maintaining adequate AFP level satisfies the oxygen content requirement to achieve the desired composting conditions and thus, tho enhance biological activity. (Author)

  14. MORPHOLOGICAL FILLING OF DIGITAL ELEVATION MODELS

    Directory of Open Access Journals (Sweden)

    T. Krauß

    2012-09-01

    Full Text Available In this paper a new approach for a more detailed post processing and filling of digital elevation models (DEMs in urban areas is presented. To reach the required specifications in a first step the errors in digital surface models (DSMs generated by dense stereo algorithms are analyzed and methods for detection and classification of the different types of errors are implemented. Subsequently the classified erroneous areas are handled in separate manner to eliminate outliers and fill the DSM properly. The errors which can be detected in DSMs range from outliers – single pixels or small areas containing extremely high or low values – over noise from mismatches, single small holes to occlusions, where large areas are not visible in one of the images of the stereo pair. To validate the presented method artificial DSMs are generated and superimposed with all different kinds of described errors like noise (small holes cut in, outliers (small areas moved up/down, occlusions (larger areas beneath steep walls and so on. The method is subsequently applied to the artificial DSMs and the resulting filled DSMs are compared to the original artificial DSMs without the introduced errors. Also the method is applied to stereo satellite generated DSMs from the ISPRS Comission 1 WG4 benchmark dataset and the results are checked with the also provided first pulse laser DSM data. Finally the results are discussed, strengths and weaknesses of the approach are shown and suggestions for application and optimization are given.

  15. Highly filled biocomposites based on ethylene-vinyl acetate copolymer and wood flour

    Science.gov (United States)

    Shelenkov, P. G.; Pantyukhov, P. V.; Popov, A. A.

    2018-05-01

    Recently, there is a great interest in the world to biodegradable materials based on synthetic polymers in a composition with natural fillers. Highly filled polymer composite materials based on various grades of synthetic block copolymer of ethylene vinyl acetate with wood flour were under investigation. Five grades of ethylene-vinyl acetate copolymer differing in the content of vinyl acetate groups and a melt flow index were used in this work in order to find the best one for highly filled biocomposites. Wood flour content in biocomposites was 50, 60, 70 weight %. The rheological and physico-mechanical characteristics of the resulting biocomposites were studied.

  16. Insulating and sheathing materials of electric and optical cables - Common test methods - Part 5-1: Methods specific to filling compounds - Drop-point - Separation of oil - Lower temperature brittleness - Total acid number - Absence of corrosive components - Permittivity at 23 °C - DC resistivity at 23 °C and 100 °C

    CERN Document Server

    International Electrotechnical Commission. Geneva

    2004-01-01

    Specifies the test methods for filling compounds of electric cables used with telecommunication equipment. Gives the methods for drop-point, separation of oil, lower temperature brittleness, total acid number, absence of corrosive components, permittivity at 23 °C, d.c. resistivity at 23°C and 100°C.

  17. Calculation of depleted uranium concentration in dental fillings samples using the nuclear track detector CR-39

    International Nuclear Information System (INIS)

    Mahdi, K. H.; Subhi, A. T.; Tawfiq, N. F.

    2012-12-01

    The purpose of this study is to determine the concentration of depleted uranium in dental fillings samples, which were obtained some hospital and dental office, sale of materials deployed in Iraq. 8 samples were examined from two different fillings and lead-filling (amalgam) and composite filling (plastic). concentrations of depleted uranium were determined in these samples using a nuclear track detector CR-39 through the recording of the tracks left by of fragments of fission resulting from the reaction 2 38U (n, f). The samples are bombarded by neutrons emitted from the neutron source (2 41A m-Be) with flux of ( 10 5 n. cm- 2. s -1 ). The period of etching to show the track of fission fragments is 5 hours using NaOH solution with normalization (6.25N), and temperature (60 o C ). Concentration of depleted uranium were calculated by comparison with standard samples. The result that obtained showed that the value of the weighted average for concentration of uranium in the samples fillings (5.54± 1.05) ppm lead to thr filling (amalgam) and (5.33±0.6) ppm of the filling composite (plastic). The hazard- index, the absorbed dose and the effective dose for these concentration were determined. The obtained results of the effective dose for each of the surface of the bone and skin (as the areas most affected by this compensation industrial) is (0.56 mSv / y) for the batting lead (amalgam) and (0.54 mSv / y) for the filling composite (plastic). From the results of study it was that the highest rate is the effective dose to a specimen amalgam filling (0.68 mSv / y) which is less than the allowable limit for exposure of the general people set the World Health Organization (WHO), a (1 mSv / y). (Author)

  18. Effect of fill volume on solidification characteristics of DI (deionized) water in a spherical capsule – An experimental study

    International Nuclear Information System (INIS)

    Chandrasekaran, P.; Cheralathan, M.; Velraj, R.

    2015-01-01

    The present study aims to investigate the solidification characteristics of water, as the PCM (phase change material), due to the effect of fill volume of PCM in a spherical capsule. The experiments were conducted with the spherical capsule, filling it with water of 80, 85, 90, 92 and 95 percentage of its full volume and immersing it in a constant temperature bath maintained at various temperatures. It was observed that the increase in fill volume had a significant influence in reducing the degree of supercooling and it was eliminated with 95% fill volume. Further, the increase in fill volume had a considerable effect in advancing the commencement of solidification. Increasing the temperature potential enhanced the heat flux during the solidification of first 50% of PCM mass and its effect was more pronounced at higher fill volumes. The heat flux was increased several fold particularly at 95% fill volume making it highly suitable for applications that demand large cooling load in a short duration. Hence the proper selection of fill volume and temperature driving potential is essential to achieve overall energy efficiency while designing the CTES (cool thermal energy storage) system. - Highlights: • Supercooling was eliminated with 95% fill volume at all surrounding bath temperature. • The effect of higher fill volume is more pronounced with higher temperature potential. • 50% mass is solidified in 10% of solidification duration with 95% fill volume at −12 °C. • Several fold increase in heat flux is achieved with 95% fill volume at −12 °C. • Combination of fill volume and temperature potential is essential for good design.

  19. Mechanical evaluation of bone gap filled with rigid formulations castor oil polyurethane and chitosan in horses

    Directory of Open Access Journals (Sweden)

    Rodrigo Crispim Moreira

    Full Text Available ABSTRACT: Often fractures of long bones in horses are comminuted and form bone gaps, which represent a major challenge for the fixation of these fractures by loss of contact between the fragments. Bone grafts help in treating this kind of fracture and synthetic materials have been gaining ground because of the limitations of autologous and heterologous grafts. In this study were performed compressive non destructive test in 10 bones with complete cross-bone gap in mid-diaphyseal of the third metacarpal bone of horses. Using a mechanism of "crossing" the 10 bones were used in the three groups (control, castor oil poliuretane and chitosan according to the filling material. After the test with maximum load of 1000N bone had a gap filled by another material and the test was repeated. Deformations caused on the whole bone, plate and bone tissue near and distant of gap were evaluated, using strain gauges adhered to the surface at these locations. There was a reduction in bone deformation from 14% (control to 3,5% and 4,8% by filling the gap with Chitosan and castor oil respectively, and a reduction of strain on the plate of 96% and 85% by filling gap with chitosan and castor respectively. An increase in intensity and direction of deformations occurred in bone near to gap after its filling; however, there was no difference in bone deformations occurring far the gap.

  20. Influence of high energy β-radiation on thermoelectric performance of filled skutterudites compounds

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jikun, E-mail: jikunchen@seas.harvard.edu [CAS Key Laboratory of Materials for Energy Conversion, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Zha, Hao [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China); Xia, Xugui; Qiu, Pengfei; Li, Yulong [CAS Key Laboratory of Materials for Energy Conversion, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Wang, Chuanjing; Han, Yunsheng [Nuctech Company Limited, Beijing (China); Shi, Xun; Chen, Lidong [CAS Key Laboratory of Materials for Energy Conversion, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Jin, Qingxiu [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China); Chen, Huaibi, E-mail: chenhb@mail.tsinghua.edu.cn [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China)

    2015-08-15

    Highlights: • Impact by MeV β-rays irradiation on skutterudite TE material was investigated. • Monte-Carlo simulation is used to simulate the deposited energy irradiations. • The high deposited energy does not change the TE performance. • The light irradiation does not show a significant impact on TE materials. - Abstract: The influence of MeV β-rays irradiation on the thermoelectric performance of n-type filled skutterudite material has been investigated using an electron accelerator. Using a Monte-Carlo simulation base on Fluka code, the deposited energy in the sample material from the irradiation is estimated, which shows a large power deposited around 50 W/mm. Nevertheless, the thermoelectric performances of the filled skutterudite samples are compared before and after irradiations. It indicates that the thermoelectric material will not be easily jeopardized by ‘light’ irradiations with energy lower than MeV range.

  1. Influence of high energy β-radiation on thermoelectric performance of filled skutterudites compounds

    International Nuclear Information System (INIS)

    Chen, Jikun; Zha, Hao; Xia, Xugui; Qiu, Pengfei; Li, Yulong; Wang, Chuanjing; Han, Yunsheng; Shi, Xun; Chen, Lidong; Jin, Qingxiu; Chen, Huaibi

    2015-01-01

    Highlights: • Impact by MeV β-rays irradiation on skutterudite TE material was investigated. • Monte-Carlo simulation is used to simulate the deposited energy irradiations. • The high deposited energy does not change the TE performance. • The light irradiation does not show a significant impact on TE materials. - Abstract: The influence of MeV β-rays irradiation on the thermoelectric performance of n-type filled skutterudite material has been investigated using an electron accelerator. Using a Monte-Carlo simulation base on Fluka code, the deposited energy in the sample material from the irradiation is estimated, which shows a large power deposited around 50 W/mm. Nevertheless, the thermoelectric performances of the filled skutterudite samples are compared before and after irradiations. It indicates that the thermoelectric material will not be easily jeopardized by ‘light’ irradiations with energy lower than MeV range

  2. Electrically conductive composite material

    Science.gov (United States)

    Clough, Roger L.; Sylwester, Alan P.

    1989-01-01

    An electrically conductive composite material is disclosed which comprises a conductive open-celled, low density, microcellular carbon foam filled with a non-conductive polymer or resin. The composite material is prepared in a two-step process consisting of first preparing the microcellular carbon foam from a carbonizable polymer or copolymer using a phase separation process, then filling the carbon foam with the desired non-conductive polymer or resin. The electrically conductive composites of the present invention has a uniform and consistant pattern of filler distribution, and as a result is superior over prior art materials when used in battery components, electrodes, and the like.

  3. Cytotoxic evaluation of hydroxyapatite-filled and silica/hydroxyapatite-filled acrylate-based restorative composite resins: An in vitro study.

    Science.gov (United States)

    Chadda, Harshita; Naveen, Sangeetha Vasudevaraj; Mohan, Saktiswaren; Satapathy, Bhabani K; Ray, Alok R; Kamarul, Tunku

    2016-07-01

    Although the physical and mechanical properties of hydroxyapatite-filled dental restorative composite resins have been examined, the biocompatibility of these materials has not been studied in detail. The purpose of this in vitro study was to analyze the toxicity of acrylate-based restorative composite resins filled with hydroxyapatite and a silica/hydroxyapatite combination. Five different restorative materials based on bisphenol A-glycidyl methacrylate (bis-GMA) and tri-ethylene glycol dimethacrylate (TEGDMA) were developed: unfilled (H0), hydroxyapatite-filled (H30, H50), and silica/hydroxyapatite-filled (SH30, SH50) composite resins. These were tested for in vitro cytotoxicity by using human bone marrow mesenchymal stromal cells. Surface morphology, elemental composition, and functional groups were determined by scanning electron microscopy (SEM), energy-dispersive x-ray spectroscopy (EDX), and Fourier-transformed infrared spectroscopy (FTIR). The spectra normalization, baseline corrections, and peak integration were carried out by OPUS v4.0 software. Both in vitro cytotoxicity results and SEM analysis indicated that the composite resins developed were nontoxic and supported cell adherence. Elemental analysis with EDX revealed the presence of carbon, oxygen, calcium, silicon, and gold, while the presence of methacrylate, hydroxyl, and methylene functional groups was confirmed through FTIR analysis. The characterization and compatibility studies showed that these hydroxyapatite-filled and silica/hydroxyapatite-filled bis-GMA/TEGDMA-based restorative composite resins are nontoxic to human bone marrow mesenchymal stromal cells and show a favorable biologic response, making them potential biomaterials. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. Controlled low strength materials (CLSM), reported by ACI Committee 229

    International Nuclear Information System (INIS)

    Rajendran, N.

    1997-01-01

    Controlled low-strength material (CLSM) is a self-compacted, cementitious material used primarily as a backfill in lieu of compacted fill. Many terms are currently used to describe this material including flowable fill, unshrinkable fill, controlled density fill, flowable mortar, flowable fly ash, fly ash slurry, plastic soil-cement, soil-cement slurry, K-Krete and other various names. This report contains information on applications, material properties, mix proportioning, construction and quality-control procedures. This report's intent is to provide basic information on CLSM technology, with emphasis on CLSM material characteristics and advantages over conventional compacted fill. Applications include backfills, structural fills, insulating and isolation fills, pavement bases, conduit bedding, erosion control, void filling, and radioactive waste management

  5. Buoyancy of gas-filled bladders at great depth

    Science.gov (United States)

    Priede, Imants G.

    2018-02-01

    At high hydrostatic pressures exceeding 20 MPa or 200 bar, equivalent to depths exceeding ca.2000 m, the behaviour of gases deviates significantly from the predictions of standard equations such as Boyle's Law, the Ideal Gas Law and Van der Waals equation. The predictions of these equations are compared with experimental data for nitrogen, oxygen and air at 0 °C and 15 °C, at pressures up to 1100 bar (110 MPa) equivalent to full ocean depth of ca. 11000 m. Owing to reduced compressibility of gases at high pressures, gas-filled bladders at full ocean depth have a density of 847 kg m-3 for Oxygen, 622 kg m-3 for Nitrogen and 660 kg m-3 for air providing potentially useful buoyancy comparable with that available from man-made materials. This helps explain why some of the deepest-living fishes at ca. 7000 m depth (700 bar or 70 MPa) have gas-filled swim bladders. A table is provided of the density and buoyancy of oxygen, nitrogen and air at 0 °C and 15 °C from 100 to 1100 bar.

  6. Fissure fillings from Gideaa, central Sweden

    International Nuclear Information System (INIS)

    Tullborg, E.L.; Larsson, S.Aa.

    1983-08-01

    The most frequent fissure filling minerals at Gideaa are calcite, chlorite, pyrite, laumontite, stilbite, smectite, quartz and epidote. Potentially young minerals, i.e. minerals which can be formed during present conditions, are smectite, calcite and quartz, Equilibrium calculations show that these minerals can be stable in the water analysed from Gideaa. In borehole Gi 2, the water exhibits a greater equilibrium with existing minerals in the fissures than water from Gi 4. This is due to the recharge of the water in Gi 4 and discharge of the water in Gi 2. When carbonate saturated water penetrated through the bedrock, calcite precipitated within the more superficial portions of the rock. However, both calcite and zeolite fissures fillings are associated with certain zones in the drill holes. A large number of fractures can be concluded to be of post-Jotnian age. Stilbite, calcite and smectite are associated with these fractures. Laumontite can also be assumed to belong here. The dolerites in the area exhibit a high fracture frequency but a relatively low hydraulic conductivity. This is due to the fact that smectite is very prevalent in the dolerite fractures, Several generations of fracturefilling minerals (above all calcite) have been found in a single fracture. Stable isotope analyses of fissure filling calcites indicate that there are three different groups of calcite. Most of the calcites could not have been precipitated from water of present-day isotope composition at Gideaa, whereas recent calcite may be found in one of the groups. Another group of calcite was precipitated during hydro-thermal conditions.(author)

  7. The effect of tube filling on the electronic properties of Fe filled carbon nanotubes

    International Nuclear Information System (INIS)

    Linganiso, Ella C.; Chimowa, George; Franklyn, Paul J.; Bhattacharyya, Somnath; Coville, Neil J.

    2012-01-01

    Graphical abstract: HRTEM image of a twisted CNT filled with a bent single crystal of Fe. Insets from top to bottom show the power spectra of the corresponding regions, indicating the twisting of the Fe lattice. Inset in the top right shows the relative angling of the lattice fringes to accommodate the twisting of the Fe. Highlights: ► Synthesis of Fe filled CNTs with Fe content varying from 3 to 35%. ► TEM analysis indicates that Fe in the tubes is in contact with the CNTs. ► TEM analysis reveals that α-Fe crystallizes after CNT formation. ► Temperature dependent electronic transport measurements performed. ► Conductivity varies with the % Fe filling in the CNTs. - Abstract: Carbon nanotubes filled with Fe nanostructures (Fe-CNTs) were synthesized using an injection method in a 1-stage horizontal CVD furnace and a bubbling method in a 2-stage horizontal CVD reactor. Fe-CNTs were obtained through the pyrolysis of a mixture of dichlorobenzene and ferrocene in 5%H 2 /Ar. Metal impurities from the Fe-CNTs were removed using 1 M HCl solution. CNTs filled with crystalline Fe nanoparticles, nanorods and nanowires were obtained using these procedures. An intimate interaction between the Fe and the CNT was established by HRTEM studies. The α-Fe phase was observed to be the most dominant fraction found in the synthesized Fe-CNTs. The Fe 2 O 3 residue obtained from the TGA analysis revealed the amount of Fe filled inside the CNTs and this ranged between 3 and 31% by mass after purification. The temperature dependence of the conductivity in the temperature range between 2.5 and 100 K for an entangled network of Fe-CNTs was measured. An increase in conductivity due to the increased Fe filling inside the CNTs with increased temperature was observed. The observed temperature dependence was explained in terms of variable range hopping (VRH) conduction mechanisms. A transition from Efros–Shklovskii behavior at low % Fe filling of the CNTs to Mott 3D VRH behavior at

  8. Multiple scattering theory for space filling potentials

    International Nuclear Information System (INIS)

    Butler, W.H.; Brown, R.G.; Nesbet, R.K.

    1990-01-01

    Multiple scattering theory (MST) provides an efficient technique for solving the wave equation for the special case of muffin-tin potentials. Here MST is extended to treat space filling non-muffin tin potentials and its validity, accuracy and efficiency are tested by application of the two dimensional empty lattice test. For this test it is found that the traditional formulation of MST does not coverage as the number of partial waves is increased. A simple modification of MST, however, allows this problem to be solved exactly and efficiently. 15 refs., 3 tabs

  9. Le déficit de filles

    International Development Research Centre (IDRC) Digital Library (Canada)

    de la population est une tendance plus récente. C. Le déficit de filles. Le déséquilibre du ratio hommes-femmes en Inde. D. R. O. I. T. S. D. E. S. F. E. M. M. E. S. E. T. P. A. R. T. IC. I. P. A. T. IO. N. C. I. T. O. Y. E. N. N. E. CENTRE DE. RECHERCHES. POUR LE. DÉVELOPPEMENT. INTERNATIONAL. CRDI : Jason Taylor ...

  10. Evaluation of Flowable Fill Surface Performance

    Science.gov (United States)

    2016-11-01

    general, traditional flowable fill is a low- viscosity , grout-like, cementitious blend commonly composed of portland cement, fine aggregate, and water...93.7 45.0 19.6 % Finer No. 200 7.0 0.5 9.1 % Gravel 2.2 0.0 56.1 % Sand 90.8 99.5 34.8 % Silt 3.2 < 0.5 6.8 % Clay 3.8 < 0.5 2.3 Fineness Modulus

  11. Dielectric properties of nanosilica filled epoxy nanocomposites

    Indian Academy of Sciences (India)

    M G Veena

    Polymer nanocomposites are the 21st century engineering materials with wide range of ... the electronic industry for dielectric materials in electrical insulation ..... be ascribed to the interface barriers and chain entangle- ments towards the ...

  12. Fracture-filling minerals as uranium sinks and sources, a natural analogue study at Palmottu, Finland

    International Nuclear Information System (INIS)

    Cui, D.; Eriksen, T.

    2000-01-01

    The nucleation of a mineral crystal and its growth in groundwater carrying fractures 300 m above the Palmottu uranium deposit provide an impressive example of geochemical selectivity of uranium. Fracture-filling material was collected from a 3 mm thick fracture at depth 74.8-75 m (drillcore R348). SEM and EDS analyses on a thin section of the original fracture-filling show that the fracture filling is heterogeneous, composing mineral crystal particles and very porous clay-rich aggregates. The results of INAA on millimetre-sized single mineral crystals and aggregates selected from grinded fracture-filling show that porous aggregates (composed of clays and micrometer sized mineral particles) contain up to 1000 ppm U, which is higher than the average of the whole fracture-filling (400 ppm) and host rock related millimetre sized mineral particles (18-100 ppm). 233 U/ 238 U isotope exchange proves that a large fraction of the uranium in the fracture-filling is not easily exchanged with uranium in the solution. The amount of 238 U released in the isotope exchange experiment is too high to be explained by reversible U(VI) sorption. Oxidation state analyses show that 30% of the uranium exists as U(IV). Laboratory batch experiment at anoxic conditions proved that pyrite can immobilise U(VI). (orig.)

  13. Simulations of indirectly driven gas-filled capsules at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Weber, S. V.; Casey, D. T.; Eder, D. C.; Pino, J. E.; Smalyuk, V. A.; Remington, B. A.; Rowley, D. P.; Yeamans, C. B.; Tipton, R. E.; Barrios, M.; Benedetti, R.; Berzak Hopkins, L.; Bleuel, D. L.; Bond, E. J.; Bradley, D. K.; Caggiano, J. A.; Callahan, D. A.; Cerjan, C. J.; Clark, D. S.; Divol, L. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2014-11-15

    Gas-filled capsules imploded with indirect drive on the National Ignition Facility have been employed as symmetry surrogates for cryogenic-layered ignition capsules and to explore interfacial mix. Plastic capsules containing deuterated layers and filled with tritium gas provide a direct measure of mix of ablator into the gas fuel. Other plastic capsules have employed DT or D{sup 3}He gas fill. We present the results of two-dimensional simulations of gas-filled capsule implosions with known degradation sources represented as in modeling of inertial confinement fusion ignition designs; these are time-dependent drive asymmetry, the capsule support tent, roughness at material interfaces, and prescribed gas-ablator interface mix. Unlike the case of cryogenic-layered implosions, many observables of gas-filled implosions are in reasonable agreement with predictions of these simulations. Yields of TT and DT neutrons as well as other x-ray and nuclear diagnostics are matched for CD-layered implosions. Yields of DT-filled capsules are over-predicted by factors of 1.4–2, while D{sup 3}He capsule yields are matched, as well as other metrics for both capsule types.

  14. Liquid-filled ionization chamber temperature dependence

    Energy Technology Data Exchange (ETDEWEB)

    Franco, L. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)]. E-mail: luciaff@usc.es; Gomez, F. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Iglesias, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pardo, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pazos, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pena, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Zapata, M. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)

    2006-05-10

    Temperature and pressure corrections of the read-out signal of ionization chambers have a crucial importance in order to perform high-precision absolute dose measurements. In the present work the temperature and pressure dependences of a sealed liquid isooctane filled ionization chamber (previously developed by the authors) for radiotherapy applications have been studied. We have analyzed the thermal response of the liquid ionization chamber in a {approx}20 deg. C interval around room temperature. The temperature dependence of the signal can be considered linear, with a slope that depends on the chamber collection electric field. For example, a relative signal slope of 0.27x10{sup -2}K{sup -1} for an operation electric field of 1.67x10{sup 6}Vm{sup -1} has been measured in our detector. On the other hand, ambient pressure dependence has been found negligible, as expected for liquid-filled chambers. The thermal dependence of the liquid ionization chamber signal can be parametrized within the Onsager theory on initial recombination. Considering that changes with temperature of the detector response are due to variations in the free ion yield, a parametrization of this dependence has been obtained. There is a good agreement between the experimental data and the theoretical model from the Onsager framework.

  15. GRAVITY PIPELINE TRANSPORT FOR HARDENING FILLING MIXTURES

    Directory of Open Access Journals (Sweden)

    Leonid KROUPNIK

    2015-12-01

    Full Text Available In underground mining of solid minerals becoming increasingly common development system with stowing hardening mixtures. In this case the natural ore array after it is replaced by an artificial excavation of solidified filling mixture consisting of binder, aggregates and water. Such a mixture is prepared on the surface on special stowing complexes and transported underground at special stowing pipelines. However, it is transported to the horizons of a few kilometers, which requires a sustainable mode of motion of such a mixture in the pipeline. Hardening stowing mixture changes its rheological characteristics over time, which complicates the calculation of the parameters of pipeline transportation. The article suggests a method of determining the initial parameters of such mixtures: the status coefficient, indicator of transportability, coefficient of hydrodynamic resistance to motion of the mixture. These indicators characterize the mixture in terms of the possibility to transport it through pipes. On the basis of these indicators is proposed methodology for calculating the parameters of pipeline transport hardening filling mixtures in drift mode when traffic on the horizontal part of the mixture under pressure column of the mixture in the vertical part of the backfill of the pipeline. This technique allows stable operation is guaranteed to provide pipeline transportation.

  16. Filling behaviour of wood plastic composites

    Science.gov (United States)

    Duretek, I.; Lucyshyn, T.; Holzer, C.

    2017-01-01

    Wood plastic composites (WPC) are a young generation of composites with rapidly growing usage within the plastics industry. The advantages are the availability and low price of the wood particles, the possibility of partially substituting the polymer in the mixture and sustainable use of the earth’s resources. The current WPC products on the market are to a large extent limited to extruded products. Nowadays there is a great interest in the market for consumer products in more use of WPC as an alternative to pure thermoplastics in injection moulding processes. This work presents the results of numerical simulation and experimental visualisation of the mould filling process in injection moulding of WPC. The 3D injection moulding simulations were done with the commercial software package Autodesk® Moldflow® Insight 2016 (AMI). The mould filling experiments were conducted with a box-shaped test part. In contrast to unfilled polymers the WPC has reduced melt elasticity so that the fountain flow often does not develop. This results in irregular flow front shapes in the moulded part, especially at high filler content.

  17. Transparent Metal-Salt-Filled Polymeric Radiation Shields

    Science.gov (United States)

    Edwards, David; Lennhoff, John; Harris, George

    2003-01-01

    "COR-RA" (colorless atomic oxygen resistant -- radiation shield) is the name of a transparent polymeric material filled with x-ray-absorbing salts of lead, bismuth, cesium, and thorium. COR-RA is suitable for use in shielding personnel against bremsstrahlung radiation from electron-beam welding and industrial and medical x-ray equipment. In comparison with lead-foil and leaded-glass shields that give equivalent protection against x-rays (see table), COR-RA shields are mechanically more durable. COR-RA absorbs not only x-rays but also neutrons and rays without adverse effects on optical or mechanical performance. The formulation of COR-RA with the most favorable mechanical-durability and optical properties contains 22 weight percent of bismuth to absorb x-rays, plus 45 atomic percent hydrogen for shielding against neutrons.

  18. Decayed/missing/filled teeth and shortened dental arches in Tanzanian adults.

    NARCIS (Netherlands)

    Sarita, P.T.N.; Witter, D.J.; Kreulen, C.M.; Matee, M.I.N.; Hof, M.A. van 't; Creugers, N.H.J.

    2004-01-01

    PURPOSE: This study assessed decayed/missing/filled teeth (DMFT), presence of occlusal units, and prevalence of shortened dental arches in a Tanzanian adult population. MATERIALS AND METHODS: The dental state of samples of the Tanzanian population was studied. Oral examinations were conducted on

  19. Light propagation in optical crystal powders: effects of particle size and volume filling factor

    International Nuclear Information System (INIS)

    GarcIa-Ramiro, B; Illarramendi, M A; Aramburu, I; Fernandez, J; Balda, R; Al-Saleh, M

    2007-01-01

    In this work, we analyse the light propagation in some laser and nonlinear crystal powders. In particular, we study the dependence of the diffusive absorption lengths and the transport lengths on particle size and volume filling factor. The theoretical calculations have been made by assuming a diffusive propagation of light in these materials

  20. Partial discharge patterns and surface deterioration in voids in filled and unfilled epoxy

    DEFF Research Database (Denmark)

    Holbøll, Joachim; Henriksen, Mogens

    1992-01-01

    /height analyses were performed over a period of 2400 h and showed very characteristic discharge patterns for each material combination. A unique behavior with regard to changes of pulse repetition rate and maximum apparent charge was observed for PD in alumina- and silica-filled epoxy. The void surfaces were...