Sample records for fielded thermal neutron

  1. Photon spectrometry in thermal neutron standard field

    CERN Document Server

    Kudo, K; Koshikawa, S; Toyokawa, H; Ohgaki, H; Matzke, M

    2002-01-01

    An NE213 liquid scintillation counter (5.08 cm in diameter and 5.08 cm long) with an LiF filter was used to measure the energy distribution of photons mixed in a thermal neutron field. The response function matrix of photons in an energy range up to 10 MeV was calculated by the EGS4/PRESTA code and properly folded with a resolution function. Pulse height spectra measured with a set of reference gamma-ray sources were compared to the calculated response function and agreed very well for all reference gamma-ray sources. The GRAVEL and MIEKE codes from the HEPRO program were used to unfold measured pulse height spectra. Energy distributions obtained by the unfolding were applied to evaluate the effective dose equivalent of photons mixed in a thermal neutron field.

  2. The Response of Alanine Dosimeters in Thermal Neutron Fields

    DEFF Research Database (Denmark)

    Schmitz, T.; Bassler, Niels; Sharpe, P.

    Purpose: Boron Neutron Capture Therapy (BNCT) is a special kind of particle therapy, based on the neutron induced fission of the boron isotope 10B [1]. We have performed dosimetry experiments on the mixed neutron and gamma fields at the TRIGA Mark II research reactor in Mainz. Commonly, dosimetry...... in such fields is realized by foil activation and ion chambers [2]. Here we investigate alanine as an easier and more robust alternative dosimeter. Methods: We have performed four phantom experiments at the TRIGA Mark II research reactor in Mainz [3], in a predominantly thermal neutron field with a strong gamma...... neutron capture of hydrogen. The primary gamma dose deposited originate from the reactor core itself. Conclusion: Alanine dosimeters are suitable of measurements in mixed neutron fields and the alanine response in thermal neutron fields can be fully understood by the used interpretation model. In further...

  3. The PTB thermal neutron reference field at GeNF

    Energy Technology Data Exchange (ETDEWEB)

    Boettger, R.; Friedrich, H.; Janssen, H.

    2004-07-01

    The experimental setup and procedure for the characterization of the thermal neutron reference field established at the Geesthacht neutron facility (GeNF) of the GKSS is described. The neutron beam, free in air, with a maximum flux of 10{sup 6} s{sup -1}, can easily be reduced to less than 10{sup 4} s{sup -1} by using a diaphragm variable in size and without changing the beam divergence. Also, the spectral distribution with a mean energy of 45 meV, measured by time-of-flight over a 6.6 m long flight path, is independent of the beam current chosen. In the 2002/2003 experiments reported here, a {sup 6}Li glass detector was employed to determine the absolute beam current and to calibrate the {sup 3}He transmission beam monitor. In addition, activation measurements of gold foils were carried out at a reduced beam divergence. The results agree within {+-}2%. Furthermore, the beam is characterized by a low gamma background intensity and a negligible fraction of epithermal neutrons. Irradiations in combination with a scanner device to achieve a homogeneously illuminated scan field have shown that the thermal beam is well suited for dosemeter development and for the calibration of radiation protection instruments. (orig.)

  4. Evaluation of thermal neutron irradiation field using a cyclotron-based neutron source for alpha autoradiography.

    Science.gov (United States)

    Tanaka, H; Sakurai, Y; Suzuki, M; Masunaga, S; Mitsumoto, T; Kinashi, Y; Kondo, N; Narabayashi, M; Nakagawa, Y; Watanabe, T; Fujimoto, N; Maruhashi, A; Ono, K

    2014-06-01

    It is important to measure the microdistribution of (10)B in a cell to predict the cell-killing effect of new boron compounds in the field of boron neutron capture therapy. Alpha autoradiography has generally been used to detect the microdistribution of (10)B in a cell. Although it has been performed using a reactor-based neutron source, the realization of an accelerator-based thermal neutron irradiation field is anticipated because of its easy installation at any location and stable operation. Therefore, we propose a method using a cyclotron-based epithermal neutron source in combination with a water phantom to produce a thermal neutron irradiation field for alpha autoradiography. This system can supply a uniform thermal neutron field with an intensity of 1.7×10(9) (cm(-2)s(-1)) and an area of 40mm in diameter. In this paper, we give an overview of our proposed system and describe a demonstration test using a mouse liver sample injected with 500mg/kg of boronophenyl-alanine.

  5. A militarily fielded thermal neutron activation sensor for landmine detection

    Energy Technology Data Exchange (ETDEWEB)

    Clifford, E.T.H. [Bubble Technology Industries, Chalk River (Canada); McFee, J.E. [Defence R and D Canada-Suffield, Medicine Hat (Canada)], E-mail: john.mcfee@drdc-rddc.gc.ca; Ing, H.; Andrews, H.R.; Tennant, D.; Harper, E. [Bubble Technology Industries, Chalk River (Canada); Faust, A.A. [Defence R and D Canada-Suffield, Medicine Hat (Canada)

    2007-08-21

    The Canadian Department of National Defence has developed a teleoperated, vehicle-mounted, multi-sensor system to detect anti-tank landmines on roads and tracks in peacekeeping operations. A key part of the system is a thermal neutron activation (TNA) sensor which is placed above a suspect location to within a 30 cm radius and confirms the presence of explosives via detection of the 10.835 MeV gamma ray associated with thermal neutron capture on {sup 14}N. The TNA uses a 100{mu}g{sup 252}Cf neutron source surrounded by four 7.62cmx7.62cm NaI(Tl) detectors. The system, consisting of the TNA sensor head, including source, detectors and shielding, the high-rate, fast pulse processing electronics and the data processing methodology are described. Results of experiments to characterize detection performance are also described. The experiments have shown that anti-tank mines buried 10 cm or less can be detected in roughly a minute or less, but deeper mines and mines significantly displaced horizontally take considerably longer time. Mines as deep as 30 cm can be detected for long count times (1000 s). Four TNA detectors are now in service with the Canadian Forces as part of the four multi-sensor systems, making it the first militarily fielded TNA sensor and the first militarily fielded confirmation sensor for landmines. The ability to function well in adverse climatic conditions has been demonstrated, both in trials and operations.

  6. Thermal neutron irradiation field design for boron neutron capture therapy of human explanted liver.

    Science.gov (United States)

    Bortolussi, S; Altieri, S

    2007-12-01

    The selective uptake of boron by tumors compared to that by healthy tissue makes boron neutron capture therapy (BNCT) an extremely advantageous technique for the treatment of tumors that affect a whole vital organ. An example is represented by colon adenocarcinoma metastases invading the liver, often resulting in a fatal outcome, even if surgical resection of the primary tumor is successful. BNCT can be performed by irradiating the explanted organ in a suitable neutron field. In the thermal column of the Triga Mark II reactor at Pavia University, a facility was created for this purpose and used for the irradiation of explanted human livers. The neutron field distribution inside the organ was studied both experimentally and by means of the Monte Carlo N-particle transport code (MCNP). The liver was modeled as a spherical segment in MCNP and a hepatic-equivalent solution was used as an experimental phantom. In the as-built facility, the ratio between maximum and minimum flux values inside the phantom ((phi(max)/phi(min)) was 3.8; this value can be lowered to 2.3 by rotating the liver during the irradiation. In this study, the authors proposed a new facility configuration to achieve a uniform thermal neutron flux distribution in the liver. They showed that a phi(max)/phi(min) ratio of 1.4 could be obtained without the need for organ rotation. Flux distributions and dose volume histograms were reported for different graphite configurations.

  7. ESR-dosimetry in thermal and epithermal neutron fields for application in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, Tobias

    2016-01-22

    Dosimetry is essential for every form of radiotherapy. In Boron Neutron Capture Therapy (BNCT) mixed neutron and gamma fields have to be considered. Dose is deposited in different neutron interactions with elements in the penetrated tissue and by gamma particles, which are always part of a neutron field. The therapeutic dose in BNCT is deposited by densely ionising particles, originating from the fragmentation of the isotope boron-10 after capture of a thermal neutron. Despite being investigated for decades, dosimetry in neutron beams or fields for BNCT remains complex, due to the variety in type and energy of the secondary particles. Today usually ionisation chambers combined with metal foils are used. The applied techniques require extensive effort and are time consuming, while the resulting uncertainties remain high. Consequently, the investigation of more effective techniques or alternative dosimeters is an important field of research. In this work the possibilities of ESR-dosimeters in those fields have been investigated. Certain materials, such as alanine, generate stable radicals upon irradiation. Using Electron Spin Resonance (ESR) spectrometry the amount of radicals, which is proportional to absorbed dose, can be quantified. Different ESR detector materials have been irradiated in the thermal neutron field of the research reactor TRIGA research reactor in Mainz, Germany, with five setups, generating different secondary particle spectra. Further irradiations have been conducted in two epithermal neutron beams. The detector response, however, strongly depends on the dose depositing particle type and energy. It is hence necessary to accompany measurements by computational modelling and simulation. In this work the Monte Carlo code FLUKA was used to calculate absorbed doses and dose components. The relative effectiveness (RE), linking absorbed dose and detector response, has been calculated using amorphous track models. For the simulation, detailed models of

  8. The optimization study of Bonner sphere in the epi-thermal neutron irradiation field for BNCT.

    Science.gov (United States)

    Ueda, H; Tanaka, H; Maruhashi, A; Ono, K; Sakurai, Y

    2011-12-01

    The optimization study on the Bonner sphere in the epi-thermal neutron irradiation field for BNCT was done for the moderator material, moderator size, and activation foils as a neutron detector in the sphere. The saturated activity for the activation foil was obtained from the calculated response, and the effective energy range for each Bonner sphere was determined from the saturated activity. We can see that boric acid solution moderator is suitable for the spectrum measurement of a epi-thermal neutron irradiation field.

  9. Design of a new IRSN thermal neutron field facility using Monte-Carlo simulations.

    Science.gov (United States)

    Lacoste, V

    2007-01-01

    The Institute for Radiological Protection and Nuclear Safety owns a graphite-moderated AmBe neutron field facility, SIGMA, that has to be reconstructed. Monte-Carlo simulations were performed to study the design of a new thermal facility based on IRSN existing facilities. Studies related to an update version of SIGMA concerned the enhancement of the thermal neutrons contribution to the dose equivalent. Calculations were mainly performed for a (252)Cf neutron source distribution located at the centre of a graphite moderator block. A quasi-pure thermal neutron field was obtained with a 2.4 x 2.4 x 2.4-m(3) block of graphite. A second acceptable neutron field was obtained with 3.3-MeV mono-energetic neutrons created by a 400-kV accelerator coupled to a graphite assembly of 1.5 x 1.5 x 1.5 m(3). The characteristics of the studied thermal fields with the requirement for a reference calibration field are compared, and the advantages and drawbacks of the different producing methods are discussed.

  10. Thermal emission from low-field neutron stars

    CERN Document Server

    Gänsicke, B T; Romani, R W

    2002-01-01

    We present a new grid of LTE model atmospheres for weakly magnetic (B<=10e10G) neutron stars, using opacity and equation of state data from the OPAL project and employing a fully frequency and angle dependent radiation transfer. We discuss the differences to earlier models, including a comparison with a detailed NLTE calculation. As a first application of the new synthetic spectra, we re-analyze the available ROSAT PSPC data of the isolated neutron star candidate RXJ1856.5-3754. Our iron and solar abundance model spectra provide satisfactory fits to the X-ray spectrum and are consistent with the distance of RXJ1856.5-3754 recently measured by the Hubble Space Telescope, although pulse fractions as small as those observed are difficult to obtain for canonical neutron star radii.

  11. The alanine detector in BNCT dosimetry: Dose response in thermal and epithermal neutron fields

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, T., E-mail: schmito@uni-mainz.de [Institute for nuclear chemistry, Johannes Gutenberg-University, Mainz D-55128 (Germany); Bassler, N. [Department of Physics and Astronomy, Aarhus University, Ny Munkegade 120, Aarhus C, Aarhus 8000 (Denmark); Blaickner, M. [AIT Austrian Institute of Technology GmbH, Vienna A-1220 (Austria); Ziegner, M. [AIT Austrian Institute of Technology GmbH, Vienna A-1220, Austria and TU Wien, Vienna University of Technology, Vienna A-1020 (Austria); Hsiao, M. C. [Insitute of Nuclear Engineering and Science, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Liu, Y. H. [Nuclear Science and Technology Development Center, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Koivunoro, H. [Department of Physics, University of Helsinki, POB 64, FI-00014, Finland and HUS Medical Imaging Center, Helsinki University Central Hospital, FI-00029 HUS (Finland); Auterinen, I.; Serén, T.; Kotiluoto, P. [VTT Technical Research Centre of Finland, Espoo (Finland); Palmans, H. [National Physical Laboratory, Acoustics and Ionising Radiation Division, Teddington TW11 0LW, United Kingdom and Medical Physics Group, EBG MedAustron GmbH, Wiener Neustadt A-2700 (Austria); Sharpe, P. [National Physical Laboratory, Acoustics and Ionising Radiation Division, Teddington TW11 0LW (United Kingdom); Langguth, P. [Department of Pharmacy and Toxicology, University of Mainz, Mainz D-55128 (Germany); Hampel, G. [Institut für Kernchemie, Johannes Gutenberg-Universität, Mainz D-55128 (Germany)

    2015-01-15

    Purpose: The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different neutron beams to explore the alanine dose response behavior and to validate model predictions. Additionally, application in medical neutron fields for boron neutron capture therapy is discussed. Methods: Alanine detectors have been irradiated in the thermal neutron field of the research reactor TRIGA Mainz, Germany, in five experimental conditions, generating different secondary particle spectra. Further irradiations have been made in the epithermal neutron beams at the research reactors FiR 1 in Helsinki, Finland, and Tsing Hua open pool reactor in HsinChu, Taiwan ROC. Readout has been performed with electron spin resonance spectrometry with reference to an absorbed dose standard in a {sup 60}Co gamma ray beam. Absorbed doses and dose components have been calculated using the Monte Carlo codes FLUKA and MCNP. The relative effectiveness (RE), linking absorbed dose and detector response, has been calculated using the Hansen and Olsen alanine response model. Results: The measured dose response of the alanine detector in the different experiments has been evaluated and compared to model predictions. Therefore, a relative effectiveness has been calculated for each dose component, accounting for its dependence on particle type and energy. Agreement within 5% between model and measurement has been achieved for most irradiated detectors. Significant differences have been observed in response behavior between thermal and epithermal neutron fields, especially regarding dose composition and depth dose curves. The calculated dose components could be verified with the experimental results in the different primary and secondary particle fields. Conclusions: The

  12. THERMAL NEUTRON BACKSCATTER IMAGING.

    Energy Technology Data Exchange (ETDEWEB)

    VANIER,P.; FORMAN,L.; HUNTER,S.; HARRIS,E.; SMITH,G.

    2004-10-16

    Objects of various shapes, with some appreciable hydrogen content, were exposed to fast neutrons from a pulsed D-T generator, resulting in a partially-moderated spectrum of backscattered neutrons. The thermal component of the backscatter was used to form images of the objects by means of a coded aperture thermal neutron imaging system. Timing signals from the neutron generator were used to gate the detection system so as to record only events consistent with thermal neutrons traveling the distance between the target and the detector. It was shown that this time-of-flight method provided a significant improvement in image contrast compared to counting all events detected by the position-sensitive {sup 3}He proportional chamber used in the imager. The technique may have application in the detection and shape-determination of land mines, particularly non-metallic types.

  13. Thermal and epithermal neutron fluence rate gradient measurements by PADC detectors in LINAC radiotherapy treatments-field

    Energy Technology Data Exchange (ETDEWEB)

    Barrera, M. T., E-mail: mariate9590@gmail.com; Barros, H.; Pino, F.; Sajo-Bohus, L. [Universidad Simón Bolívar, Nuclear Physics Laboratory, Sartenejas, Caracas (Venezuela, Bolivarian Republic of); Dávila, J. [Física Médica C. A. and Universidad Central de Venezuela, Caracas (Venezuela, Bolivarian Republic of)

    2015-07-23

    LINAC VARIAN 2100 is where energetic electrons produce Bremsstrahlung radiation, with energies above the nucleon binding energy (E≈5.5MeV). This radiation induce (γ,n) and (e,e’n) reactions mainly in the natural tungsten target material (its total photoneutron cross section is about 4000 mb in a energy range from 9-17 MeV). These reactions may occur also in other components of the system (e.g. multi leaf collimator). During radiation treatment the human body may receive an additional dose inside and outside the treated volume produced by the mentioned nuclear reactions. We measured the neutron density at the treatment table using nuclear track detectors (PADC-NTD). These covered by a boron-converter are employed, including a cadmium filter, to determine the ratio between two groups of neutron energy, i.e. thermal and epithermal. The PADC-NTD detectors were exposed to the radiation field at the iso-center during regular operation of the accelerator. Neutron are determined indirectly by the converting reaction {sup 10}B(n,α){sup 7}Li the emerging charged particle leave their kinetic energy in the PADC forming a latent nuclear track, enlarged by chemical etching (6N, NaOH, 70°C). Track density provides information on the neutron density through calibration coefficient (∼1.6 10{sup 4} neutrons /track) obtained by a californium source. We report the estimation of the thermal and epithermal neutron field and its gradient for photoneutrons produced in radiotherapy treatments with 18 MV linear accelerators. It was obsered that photoneutron production have higher rate at the iso-center.

  14. The imprint of the crustal magnetic field on the thermal spectra and pulse profiles of isolated neutron stars

    CERN Document Server

    Perna, Rosalba; Pons, Jose' A; Rea, Nanda

    2013-01-01

    Isolated neutron stars (NSs) show a bewildering variety of astrophysical manifestations, presumably shaped by the magnetic field strength and topology at birth. Here, using state-of-the art calculations of the coupled magnetic and thermal evolution of NSs, we compute the thermal spectra and pulse profiles expected for a variety of initial magnetic field configurations. In particular, we contrast models with purely poloidal magnetic fields to models dominated by a strong internal toroidal component. We find that, while the former displays double peaked profiles and very low pulsed fractions, in the latter, the anisotropy in the surface temperature produced by the toroidal field often results in a single pulse profile, with pulsed fractions that can exceed the 50-60% level even for perfectly isotropic local emission. We further use our theoretical results to generate simulated "observed" spectra, and show that blackbody (BB) fits result in inferred radii that can be significantly smaller than the actual NS radi...

  15. Fission Product Yields of 233U, 235U, 238U and 239Pu in Fields of Thermal Neutrons, Fission Neutrons and 14.7-MeV Neutrons

    Science.gov (United States)

    Laurec, J.; Adam, A.; de Bruyne, T.; Bauge, E.; Granier, T.; Aupiais, J.; Bersillon, O.; Le Petit, G.; Authier, N.; Casoli, P.

    2010-12-01

    The yields of more than fifteen fission products have been carefully measured using radiochemical techniques, for 235U(n,f), 239Pu(n,f) in a thermal spectrum, for 233U(n,f), 235U(n,f), and 239Pu(n,f) reactions in a fission neutron spectrum, and for 233U(n,f), 235U(n,f), 238U(n,f), and 239Pu(n,f) for 14.7 MeV monoenergetic neutrons. Irradiations were performed at the EL3 reactor, at the Caliban and Prospero critical assemblies, and at the Lancelot electrostatic accelerator in CEA-Valduc. Fissions were counted in thin deposits using fission ionization chambers. The number of fission products of each species were measured by gamma spectrometry of co-located thick deposits.

  16. Thermal neutron flux distribution in ET-RR-2 reactor thermal column

    OpenAIRE

    Imam Mahmoud M.; Roushdy Hassan

    2002-01-01

    The thermal column in the ET-RR-2 reactor is intended to promote a thermal neutron field of high intensity and purity to be used for following tasks: (a) to provide a thermal neutron flux in the neutron transmutation silicon doping, (b) to provide a thermal flux in the neutron activation analysis position, and (c) to provide a thermal neutron flux of high intensity to the head of one of the beam tubes leading to the room specified for boron thermal neutron capture therapy. It was, therefore, ...

  17. Compound Refractive Lenses for Thermal Neutron Applications

    Energy Technology Data Exchange (ETDEWEB)

    Gary, Charles K.

    2013-11-12

    This project designed and built compound refractive lenses (CRLs) that are able to focus, collimate and image using thermal neutrons. Neutrons are difficult to manipulate compared to visible light or even x rays; however, CRLs can provide a powerful tool for focusing, collimating and imaging neutrons. Previous neutron CRLs were limited to long focal lengths, small fields of view and poor resolution due to the materials available and manufacturing techniques. By demonstrating a fabrication method that can produce accurate, small features, we have already dramatically improved the focal length of thermal neutron CRLs, and the manufacture of Fresnel lens CRLs that greatly increases the collection area, and thus efficiency, of neutron CRLs. Unlike a single lens, a compound lens is a row of N lenslets that combine to produce an N-fold increase in the refraction of neutrons. While CRLs can be made from a variety of materials, we have chosen to mold Teflon lenses. Teflon has excellent neutron refraction, yet can be molded into nearly arbitrary shapes. We designed, fabricated and tested Teflon CRLs for neutrons. We demonstrated imaging at wavelengths as short as 1.26 ? with large fields of view and achieved resolution finer than 250 μm which is better than has been previously shown. We have also determined designs for Fresnel CRLs that will greatly improve performance.

  18. The thermal neutron facility HOTNES: theoretical design.

    Science.gov (United States)

    Bedogni, R; Pietropaolo, A; Gomez-Ros, J M

    2017-09-01

    HOTNES (HOmogeneous Thermal NEutron Source) is a thermal neutron irradiation facility with extended and very uniform irradiation area. A (241)Am-B radionuclide neutron source with nominal strenght 3.5×10(6) s(-1) is located on bottom of a large cylindrical cavity (30cm diameter, 70cm in height) delimited by polyethylene walls. The upper part of this volume (30cm diameter, 40cm in height) is used to irradiate samples. A polyethylene cylinder, acting as shadowing object, prevents fast neutrons to directly reach the irradiation volume. Indeed neutrons can only reach the irradiation volume after multiple scattering with the cavity walls. The facility was designed trough extensive calculations with MCNPX. Irradiation planes are disks with 30cm diameter, centred on the cavity axis, and parallel to the cavity bottom. The value of thermal fluence in a given irradiation plane is as uniform as 1-2%. The value of thermal fluence rate simply depends on the height from the cavity bottom. Values of thermal fluence rate in the range 700-1000cm(-2)s(-1) are available, depending on the irradiation plane chosen. The fraction of thermal neutrons is in the order of 90%, also depending on the irradiation plane. The angular distribution of thermal neutrons is roughly isotropic. Taking advantage of the HOTNES design, even large devices can be uniformly irradiated. This work presents HOTNES's design and describes the neutron field in the irradiation volume in terms of spatial, energy and direction distributions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Thermal radiation from magnetic neutron star surfaces

    CERN Document Server

    Pérez-Azorin, J F; Pons, J A

    2005-01-01

    We investigate the thermal emission from magnetic neutron star surfaces in which the cohesive effects of the magnetic field have produced the condensation of the atmosphere and the external layers. This may happen for sufficiently cool atmospheres with moderately intense magnetic fields. The thermal emission from an isothermal bare surface of a neutron star shows no remarkable spectral features, but it is significantly depressed at energies below some threshold energy. However, since the thermal conductivity is very different in the normal and parallel directions to the magnetic field lines, the presence of the magnetic field is expected to produce a highly anisotropic temperature distribution, depending on the magnetic field geometry. In this case, the observed flux of such an object looks very similar to a BB spectrum, but depressed in a nearly constant factor at all energies. This results in a systematic underestimation of the area of the emitter (and therefore its size) by a factor 5-10 (2-3).

  20. Fail-safe neutron shutter used for thermal neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Sachs, R.D.; Morris, R.A.

    1976-11-01

    A fail-safe, reliable, easy-to-use neutron shutter was designed, built, and put into operation at the Omega West Reactor, Los Alamos Scientific Laboratory. The neutron shutter will be used primarily to perform thermal neutron radiography, but is also available for a highly collimated source of thermal neutrons (neutron flux = 3.876 x 10/sup 6/ (neutrons)/(cm/sup 2/.s)). Neutron collimator sizes of either 10.16 by 10.16 cm or 10.16 by 30.48 cm are available.

  1. Forming images with thermal neutrons

    Science.gov (United States)

    Vanier, Peter E.; Forman, Leon

    2003-01-01

    Thermal neutrons passing through air have scattering lengths of about 20 meters. At further distances, the majority of neutrons emanating from a moderated source will scatter multiple times in the air before being detected, and will not retain information about the location of the source, except that their density will fall off somewhat faster than 1/r2. However, there remains a significant fraction of the neutrons that will travel 20 meters or more without scattering and can be used to create an image of the source. A few years ago, a proof-of-principle "camera" was demonstrated that could produce images of a scene containing sources of thermalized neutrons and could locate a source comparable in strength with an improvised nuclear device at ranges over 60 meters. The instrument makes use of a coded aperture with a uniformly redundant array of openings, analogous to those used in x-ray and gamma cameras. The detector is a position-sensitive He-3 proportional chamber, originally used for neutron diffraction. A neutron camera has many features in common with those designed for non-focusable photons, as well as some important differences. Potential applications include detecting nuclear smuggling, locating non-metallic land mines, assaying nuclear waste, and surveying for health physics purposes.

  2. Thermalization of monoenergetic neutrons in a concrete room

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Mercado, G.A. [UAZ, A.P. 336, 98000 Zacatecas (Mexico); Iniguez, M.P.; Martin M, A. [Universidad de Valladolid, (Spain)

    2006-07-01

    The thermalization of neutrons from monoenergetic neutron sources in a concrete room has been studied. During calibration of neutron detectors it is mandatory to make corrections due to neutron scattering produced by the room walls, therefore this factor must be known in advance. The scattered neutrons are thermalized and produce a neutron field that is directly proportional to source strength and inversely proportional to room total wall-surfaces, the proportional coefficient has been calculated for neutrons whose energy goes from 1 eV to 20 MeV. This coefficient was calculated using Monte Carlo methods for 150, 200 and 300 cm-radius spherical cavity, where monoenergetic neutrons were located at the center, along the spherical cavity radius neutron spectra were calculated at several source-to-detector distances inside the cavity. The obtained coefficient is almost three times larger than the factor normally utilized. (Author)

  3. Magneto--thermal evolution of neutron stars

    CERN Document Server

    Pons, J A; Geppert, U

    2008-01-01

    We study the mutual influence of thermal and magnetic evolution in a neutron star's crust in axial symmetry. Taking into account realistic microphysical inputs, we find the heat released by Joule effect consistent with the circulation of currents in the crust, and we incorporate its effects in 2D cooling calculations. We solve the induction equation numerically using a hybrid method (spectral in angles, but a finite--differences scheme in the radial direction), coupled to the thermal diffusion equation. We present the first long term 2D simulations of the coupled magneto-thermal evolution of neutron stars. This substantially improves previous works in which a very crude approximation in at least one of the parts (thermal or magnetic diffusion) has been adopted. Our results show that the feedback between Joule heating and magnetic diffusion is strong, resulting in a faster dissipation of the stronger fields during the first million years of a NS's life. As a consequence, all neutron stars born with fields larg...

  4. Thermal neutron flux distribution in ET-RR-2 reactor thermal column

    Directory of Open Access Journals (Sweden)

    Imam Mahmoud M.

    2002-01-01

    Full Text Available The thermal column in the ET-RR-2 reactor is intended to promote a thermal neutron field of high intensity and purity to be used for following tasks: (a to provide a thermal neutron flux in the neutron transmutation silicon doping, (b to provide a thermal flux in the neutron activation analysis position, and (c to provide a thermal neutron flux of high intensity to the head of one of the beam tubes leading to the room specified for boron thermal neutron capture therapy. It was, therefore, necessary to determine the thermal neutron flux at above mentioned positions. In the present work, the neutron flux in the ET-RR-2 reactor system was calculated by applying the three dimensional diffusion depletion code TRITON. According to these calculations, the reactor system is composed of the core, surrounding external irradiation grid, beryllium block, thermal column and the water reflector in the reactor tank next to the tank wall. As a result of these calculations, the thermal neutron fluxes within the thermal column and at irradiation positions within the thermal column were obtained. Apart from this, the burn up results for the start up core calculated according to the TRITION code were compared with those given by the reactor designer.

  5. Novel Boron Based Multilayer Thermal Neutron Detector

    CERN Document Server

    SCHIEBER, M

    2010-01-01

    The detector contains four or more layers of natural Boron absorbing thermal neutrons. Thickness of a layer is 0.4 - 1.2 mg/cm2. The layers are deposited on one or on both sides of a metal surface used as contacts. Between the absorbing layers there are gas-filled gaps 3 - 6 mm thick. Electric field of 100 - 200 V/cm is applied to the gas-filled gaps. Natural Boron contains almost 20% of 10B isotope. When atoms of 10B capture a thermal neutron, nuclear reaction occurs, as a result of which two heavy particles - alpha particle and ion 7Li - from the thin absorber layer are emitted in opposing sides. One of the two particles penetrates into gas-filled gap between Boron layers and ionizes the gas. An impulse of electric current is created in the gas-filled gap actuated by the applied electric field. The impulse is registered by an electronic circuit. We have made and tested detectors containing from two to sixteen layers of natural Boron with an efficiency of thermal neutron registration from 2.9% to 12.5% accor...

  6. Using thermalizers in measuring 'Ukryttia' object's FCM neutron fluxes

    CERN Document Server

    Krasnyanskaya, O G; Odinokin, G I; Pavlovich, V N

    2003-01-01

    The results of research of a thermalizer (heater) width influence on neutron thermalization efficiency during FCM neutron flux measuring in the 'Ukryttia' are described. The calculations of neutron flux densities were performed by the Monte-Carlo method with the help of computer code MCNP-4C for FCM different models.Three possible installations of detectors were considered: on FCM surface,inside the FCM, and inside the concrete under the FCM layer. It was shown,that in order to increase the sensitivity of neutron detectors in intermediate and fast neutrons field,and consequently, to decrease the dependence of the readings of spectral distribution of neutron flux,it is necessary to position the detector inside the so-called thermalizer or heater. The most reasonable application of thick 'heaters' is the situation, when the detector is placed on FCM surface.

  7. Testing and linearity calibration of films of phenol compounds exposed to thermal neutron field for EPR dosimetry.

    Science.gov (United States)

    Gallo, S; Panzeca, S; Longo, A; Altieri, S; Bentivoglio, A; Dondi, D; Marconi, R P; Protti, N; Zeffiro, A; Marrale, M

    2015-12-01

    This paper reports the preliminary results obtained by Electron Paramagnetic Resonance (EPR) measurements on films of IRGANOX® 1076 phenols with and without low content (5% by weight) of gadolinium oxide (Gd2O3) exposed in the thermal column of the Triga Mark II reactor of LENA (Laboratorio Energia Nucleare Applicata) of Pavia (Italy). Thanks to their size, the phenolic films here presented are good devices for the dosimetry of beams with high dose gradient and which require accurate knowledge of the precise dose delivered. The dependence of EPR signal as function of neutron dose was investigated in the fluence range between 10(11) cm(-2) and 10(14) cm(-2). Linearity of EPR response was found and the signal was compared with that of commercial alanine films. Our analysis showed that gadolinium oxide (5% by weight) can enhance the thermal neutron sensitivity more than 18 times. Irradiated dosimetric films of phenolic compound exhibited EPR signal fading of about 4% after 10 days from irradiation.

  8. Deconfinement Phase Transition Heating and Thermal Evolution of Neutron Stars

    CERN Document Server

    Kang, Miao; Wang, Xiaodong

    2007-01-01

    The deconfinement phase transition will lead to the release of latent heat during spins down of neutron stars if the transition is the first-order one.We have investigated the thermal evolution of neutron stars undergoing such deconfinement phase transition. The results show that neutron stars may be heated to higher temperature.This feature could be particularly interesting for high temperature of low-magnetic field millisecond pulsar at late stage.

  9. Magnetic fields in Neutron Stars

    CERN Document Server

    Viganò, Daniele; Miralles, Juan A; Rea, Nanda

    2015-01-01

    Isolated neutron stars show a diversity in timing and spectral properties, which has historically led to a classification in different sub-classes. The magnetic field plays a key role in many aspects of the neutron star phenomenology: it regulates the braking torque responsible for their timing properties and, for magnetars, it provides the energy budget for the outburst activity and high quiescent luminosities (usually well above the rotational energy budget). We aim at unifying this observational variety by linking the results of the state-of-the-art 2D magneto-thermal simulations with observational data. The comparison between theory and observations allows to place two strong constraints on the physical properties of the inner crust. First, strong electrical currents must circulate in the crust, rather than in the star core. Second, the innermost part of the crust must be highly resistive, which is in principle in agreement with the presence of a novel phase of matter so-called nuclear pasta phase.

  10. Magnetic Fields of Neutron Stars

    Indian Academy of Sciences (India)

    Sushan Konar

    2017-09-01

    This article briefly reviews our current understanding of the evolution of magnetic fields in neutron stars, which basically defines the evolutionary pathways between different observational classes of neutron stars. The emphasis here is on the evolution in binary systems and the newly emergent classes of millisecond pulsars.

  11. Cosmic-ray neutron transport at a forest field site

    DEFF Research Database (Denmark)

    Andreasen, Mie; Jensen, Karsten Høgh; Desilets, Darin

    2017-01-01

    parameters describing the subsurface to match measured height profiles and time series of thermal and epithermal neutron intensities at a field site in Denmark. Overall, modeled thermal and epithermal neutron intensities are in satisfactory agreement with measurements; however, the choice of forest canopy...... conceptualization is found to be significant. Modeling results show that the effect of canopy interception, soil chemistry and dry bulk density of litter and mineral soil on neutron intensity is small. On the other hand, the neutron intensity decreases significantly with added litter-layer thickness, especially...... for epithermal neutron energies. Forest biomass also has a significant influence on the neutron intensity height profiles at the examined field site, altering both the shape of the profiles and the ground-level thermal-to-epithermal neutron ratio. This ratio increases with increasing amounts of biomass...

  12. Thermal neutron shield and method of manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Metzger, Bert Clayton; Brindza, Paul Daniel

    2014-03-04

    A thermal neutron shield comprising boron shielding panels with a high percentage of the element Boron. The panel is least 46% Boron by weight which maximizes the effectiveness of the shielding against thermal neutrons. The accompanying method discloses the manufacture of boron shielding panels which includes enriching the pre-cursor mixture with varying grit sizes of Boron Carbide.

  13. Thermal neutron shield and method of manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Brindza, Paul Daniel; Metzger, Bert Clayton

    2013-05-28

    A thermal neutron shield comprising concrete with a high percentage of the element Boron. The concrete is least 54% Boron by weight which maximizes the effectiveness of the shielding against thermal neutrons. The accompanying method discloses the manufacture of Boron loaded concrete which includes enriching the concrete mixture with varying grit sizes of Boron Carbide.

  14. Research of Multi Detectors of Neutron Spectrum in Mix Fields

    Institute of Scientific and Technical Information of China (English)

    LI; Wei; CHEN; Jun; WANG; Zhi-qiang; LI; Chun-juan; LIU; Yi-na; LUO; Hai-long; ZHANG; Wei-hua

    2013-01-01

    This neutron spectrometer can be used to measure neutron spectrum and neutron equivalent dosimetry.The range of neutron spectrum is thermal-20 MeV,and the range of neutron equivalent dosimetry is 1μSv·h-1-4 mSv·h-1.The sensor head of the neutron spectrum of multi detectors in mix fields houses five gas-filled sensors and a photo-scintillator column.There are two boron tri-fluoride(BF3)and three hydrogen

  15. Calculating and measuring thermal neutrons exiting from neutron diffractometers collimators

    CERN Document Server

    Tafazolee, K

    2000-01-01

    process, effectiveness of them are studied for the enhancement of the available system. Final conclusion from the simulation process, indicates that the heavy water with the thickness of 50 to 60 cm. is the best moderator for gaining the better thermal neutrons flux for enhancement of P.N.D. in the T.R.R. Powder Neutron Diffractometer y (P.N.D.) is relatively good and practical way for identification of the 3 dimensional construction of materials. In order to exploit the capabilities of this method, in one of the neutron beam of the Tehran Research Reactor (T.R.R.), a collimator embedded inside the concrete wall, direct the neutrons produced in the core reactor towards a monochromator e. Neutrons having been monochromated by 2 nd collimator are then directed towards the sample. Then the pattern of diffracted neutrons from the sample are studied. In order to make the best out of it, neutrons coming to sit on the sample must be of the thermal type. That means the number/amount of thermal neutrons flux in compar...

  16. Selective data analysis for diamond detectors in neutron fields

    Science.gov (United States)

    Weiss, Christina; Frais-Kölbl, Helmut; Griesmayer, Erich; Kavrigin, Pavel

    2017-09-01

    Detectors based on synthetic chemical vapor deposition diamond gain importance in various neutron applications. The superior thermal robustness and the excellent radiation hardness of diamond as well as its excellent electronic properties make this material uniquely suited for rough environments, such as nuclear fission and fusion reactors. The intrinsic electronic properties of single-crystal diamond sensors allow distinguishing various interactions in the detector. This can be used to successfully suppress background of γ-rays and charged particles in different neutron experiments, such as neutron flux measurements in thermal nuclear reactors or cross-section measurements in fast neutron fields. A novel technique of distinguishing background reactions in neutron experiments with diamond detectors will be presented. A proof of principle will be given on the basis of experimental results in thermal and fast neutron fields.

  17. Selective data analysis for diamond detectors in neutron fields

    Directory of Open Access Journals (Sweden)

    Weiss Christina

    2017-01-01

    Full Text Available Detectors based on synthetic chemical vapor deposition diamond gain importance in various neutron applications. The superior thermal robustness and the excellent radiation hardness of diamond as well as its excellent electronic properties make this material uniquely suited for rough environments, such as nuclear fission and fusion reactors. The intrinsic electronic properties of single-crystal diamond sensors allow distinguishing various interactions in the detector. This can be used to successfully suppress background of γ-rays and charged particles in different neutron experiments, such as neutron flux measurements in thermal nuclear reactors or cross-section measurements in fast neutron fields. A novel technique of distinguishing background reactions in neutron experiments with diamond detectors will be presented. A proof of principle will be given on the basis of experimental results in thermal and fast neutron fields.

  18. Thermal Neutron Imaging Using A New Pad-Based Position Sensitive Neutron Detector

    Energy Technology Data Exchange (ETDEWEB)

    Dioszegi I.; Vanier P.E.; Salwen C.; Chichester D.L.; Watson S.M.

    2016-10-29

    Thermal neutrons (with mean energy of 25 meV) have a scattering mean free path of about 20 m in air. Therefore it is feasible to find localized thermal neutron sources up to ~30 m standoff distance using thermal neutron imaging. Coded aperture thermal neutron imaging was developed in our laboratory in the nineties, using He-3 filled wire chambers. Recently a new generation of coded-aperture neutron imagers has been developed. In the new design the ionization chamber has anode and cathode planes, where the anode is composed of an array of individual pads. The charge is collected on each of the individual 5x5 mm2 anode pads, (48x48 in total, corresponding to 24x24 cm2 sensitive area) and read out by application specific integrated circuits (ASICs). The high sensitivity of the ASICs allows unity gain operation mode. The new design has several advantages for field deployable imaging applications, compared to the previous generation of wire-grid based neutron detectors. Among these are the rugged design, lighter weight and use of non-flammable stopping gas. For standoff localization of thermalized neutron sources a low resolution (11x11 pixel) coded aperture mask has been fabricated. Using the new larger area detector and the coarse resolution mask we performed several standoff experiments using moderated californium and plutonium sources at Idaho National Laboratory. In this paper we will report on the development and performance of the new pad-based neutron camera, and present long range coded-aperture images of various thermalized neutron sources.

  19. Thermal neutron dosimetry using electrochemical etching

    Energy Technology Data Exchange (ETDEWEB)

    Su, S.J.; Sanders, M.E.; Morgan, K.Z.

    1979-07-10

    This study demonstrates the feasibility of using high LET particle radiators to determine the thermal neutron dose by reaction particle registration in low background polycarbonate foils using electrochemical etching. When used in conjunction with the already proven fast neutron recoil particle track registration technique, a viable fast and thermal neutron dosimeter is realized with the advantages of being: non-fading, insensitive to low LET radiation reactions, inexpensive in both processing and materials, useable over a wide dose range, a permanant record and good reproducibility, highly sensitive, and tissue equivalent and a dose equivalent response over a wide range. Most importantly, it finally provides a simple and reliable dosimeter for both the fast and thermal neutron components.

  20. Magnetic fields of neutron stars

    CERN Document Server

    Reisenegger, Andreas

    2013-01-01

    Neutron stars contain the strongest magnetic fields known in the Universe. In this paper, I discuss briefly how these magnetic fields are inferred from observations, as well as the evidence for their time-evolution. I show how these extremely strong fields are actually weak in terms of their effects on the stellar structure, as is also the case for magnetic stars on the upper main sequence and magnetic white dwarfs, which have similar total magnetic fluxes. I propose a scenario in which a stable hydromagnetic equilibrium (containing a poloidal and a toroidal field component) is established soon after the birth of the neutron star, aided by the strong compositional stratification of neutron star matter, and this state is slowly eroded by non-ideal magnetohydrodynamic processes such as beta decays and ambipolar diffusion in the core of the star and Hall drift and breaking of the solid in its crust. Over sufficiently long time scales, the fluid in the neutron star core will behave as if it were barotropic, becau...

  1. Instrumentation To Handle Thermal-polarized Neutron Beams

    CERN Document Server

    Kraan, W H

    2004-01-01

    In this thesis we investigate devices needed to handle the polarization of thermal neutron beams: π/2- flippers (to start/stop Larmor precession) and π- flippers (to reverse polarization/ precession direction) and illustrate how these devices are used to investigate the properties of matter and of the neutron. The central theme is: demonstration—for the full thermal spectrum—of a special mode of Larmor precession (called “zero-field”-precession) over the neutron beam path length between two “adiabatic Radio-Frequency flippers”. This technique enables one to build neutron spin-echo spectrometers with exceedingly large precession angles, without applying magnetic fields over long distances (meters). As an extension of this demonstration, a prototype S&barbelow;pin-E&barbelow;cho instrument for S&barbelow;mall A&barbelow;ngle N&barbelow;eutron S&barbelow;cattering (SESANS) was built, based on similar flippers with s...

  2. EAS thermal neutron lateral and temporal distributions

    CERN Document Server

    Stenkin, Yu V; Petrukhin, A A; Shchegolev, O B; Stepanov, V I; Volchenko, V I; Yashin, I I; Zadeba, E A

    2015-01-01

    A novel type of EAS array (PRISMA-32) has been constructed on the base of NEVOD-DECOR experiment (MEPhI,Moscow) and is now taking data. It consists of 32 specially designed scintillator en-detectors able to measure two main EAS components: hadrons (n) and electrons (e). First results on thermal neutron lateral as well as temporal distributions are presented. Obtained exponential neutron lateral distributions are consistent with that expected for normal hadron production with exponential transverse momentum distribution. As there are no other experimental data on thermal neutron distributions and so, to compare results with other measurements, we additionally obtained electron lateral distribution function (using the same detectors) and compared it with NKG - function. Recorded neutron temporal distributions are very close to that obtained with data of our previous prototypes.

  3. Introduction to the theory of thermal neutron scattering

    CERN Document Server

    Squires, G L

    2012-01-01

    Since the advent of the nuclear reactor, thermal neutron scattering has proved a valuable tool for studying many properties of solids and liquids, and research workers are active in the field at reactor centres and universities throughout the world. This classic text provides the basic quantum theory of thermal neutron scattering and applies the concepts to scattering by crystals, liquids and magnetic systems. Other topics discussed are the relation of the scattering to correlation functions in the scattering system, the dynamical theory of scattering and polarisation analysis. No previous knowledge of the theory of thermal neutron scattering is assumed, but basic knowledge of quantum mechanics and solid state physics is required. The book is intended for experimenters rather than theoreticians, and the discussion is kept as informal as possible. A number of examples, with worked solutions, are included as an aid to the understanding of the text.

  4. Experimental verification of improved depth-dose distribution using hyper-thermal neutron incidence in neutron capture therapy

    Science.gov (United States)

    Sakurai, Yoshinori; Kobayashi, Tooru

    2001-01-01

    We have proposed the utilization of `hyper-thermal neutrons' for neutron capture therapy (NCT) from the viewpoint of the improvement in the dose distribution in a human body. In order to verify the improved depth-dose distribution due to hyper-thermal neutron incidence, two experiments were carried out using a test-type hyper-thermal neutron generator at a thermal neutron irradiation field in Kyoto University Reactor (KUR), which is actually utilized for NCT clinical irradiation. From the free-in-air experiment for the spectrum-shift characteristics, it was confirmed that the hyper-thermal neutrons of approximately 860 K at maximum could be obtained by the generator. From the phantom experiment, the improvement effect and the controllability for the depth-dose distribution were confirmed. For example, it was found that the relative neutron depth-dose distribution was about 1 cm improved with the 860 K hyper-thermal neutron incidence, compared to the normal thermal neutron incidence.

  5. Experimental verification of improved depth-dose distribution using hyper-thermal neutron incidence in neutron capture therapy.

    Science.gov (United States)

    Sakurai, Y; Kobayashi, T

    2001-01-01

    We have proposed the utilization of 'hyper-thermal neutrons' for neutron capture therapy (NCT) from the viewpoint of the improvement in the dose distribution in a human body. In order to verify the improved depth-dose distribution due to hyper-thermal neutron incidence, two experiments were carried out using a test-type hyper-thermal neutron generator at a thermal neutron irradiation field in Kyoto University Reactor (KUR), which is actually utilized for NCT clinical irradiation. From the free-in-air experiment for the spectrum-shift characteristics, it was confirmed that the hyper-thermal neutrons of approximately 860 K at maximum could be obtained by the generator. From the phantom experiment, the improvement effect and the controllability for the depth-dose distribution were confirmed. For example, it was found that the relative neutron depth-dose distribution was about 1 cm improved with the 860 K hyper-thermal neutron incidence, compared to the normal thermal neutron incidence.

  6. New PTB thermal neutron calibration facility: first results.

    Science.gov (United States)

    Luszik-Bhadra, M; Reginatto, M; Wershofen, H; Wiegel, B; Zimbal, A

    2014-10-01

    A new thermal neutron calibration facility based on a moderator assembly has been set up at PTB. It consists of 16 (241)Am-Be radionuclide sources mounted in a graphite block, 1.5 m wide, 1.5 m high and 1.8 m deep. The sources are distributed to eight different positions, at a mean distance of ∼1.25 m from the front face of the moderator. The neutron field at the reference position, 30 cm in front of the moderator device and 75 cm above the floor, has been characterised using calculations, Bonner sphere measurements and gold foil activation. First results are shown. The field is highly thermalised: 99 % in terms of fluence. It is quite homogenous within a 20 cm×20 cm area, but the absolute value of the thermal neutron fluence rate is small and yields an ambient dose equivalent rate of 3 µSv h(-1).

  7. High precision thermal neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Radeka, V.; Schaknowski, N.A.; Smith, G.C.; Yu, B. [Brookhaven National Laboratory, Upton, NY (United States)

    1994-12-31

    Two-dimensional position sensitive detectors are indispensable in neutron diffraction experiments for determination of molecular and crystal structures in biology, solid-state physics and polymer chemistry. Some performance characteristics of these detectors are elementary and obvious, such as the position resolution, number of resolution elements, neutron detection efficiency, counting rate and sensitivity to gamma-ray background. High performance detectors are distinguished by more subtle characteristics such as the stability of the response (efficiency) versus position, stability of the recorded neutron positions, dynamic range, blooming or halo effects. While relatively few of them are needed around the world, these high performance devices are sophisticated and fairly complex, their development requires very specialized efforts. In this context, we describe here a program of detector development, based on {sup 3}He filled proportional chambers, which has been underway for some years at the Brookhaven National Laboratory. Fundamental approaches and practical considerations are outlined that have resulted in a series of high performance detectors with the best known position resolution, position stability, uniformity of response and reliability over time, for devices of this type.

  8. Instrumentation to handle thermal polarized neutron beams

    NARCIS (Netherlands)

    Kraan, W.H.

    2004-01-01

    In this thesis we investigate devices needed to handle the polarization of thermal neutron beams: Ï/2-flippers (to start/stop Larmor precession) and Ï-flippers (to reverse polarization/precession direction) and illustrate how these devices are used to investigate the properties of matter and of the

  9. Thermal annealing in neutron-irradiated tribromobenzenes

    DEFF Research Database (Denmark)

    Siekierska, K.E.; Halpern, A.; Maddock, A. G.

    1968-01-01

    The distribution of 82Br among various products in neutron-irradiated isomers of tribromobenzene has been investigated, and the effect of thermal annealing examined. Reversed-phase partition chromatography was employed for the determination of radioactive organic products, and atomic bromine...

  10. Fast and thermal neutron profiles for a 25-MV x-ray beam.

    Science.gov (United States)

    Price, K W; Nath, R; Holeman, G R

    1978-01-01

    High-energy x-ray radiotherapy machines generate neutrons by photonuclear reactions in the target and the treatment head and expose the patient to a neutron flux. In order to evaluate the neutron exposure quantitatively, fast and thermal neutron profiles for 25-MV x-ray beams of the Sagittaire accelerator have been measured. An activation technique, using the reactions 31P(n, gamma)32P (thermal neutrons) and 31P(n, p)31Si (fast neutrons, E greater than 0.7 MeV), has been developed to measure fast- and thermal-neutron fluxes in an intense high-energy photon flux. The sensitivity of this activation detector to high-energy photons, which has plagued many previous neutron measurements, was carefully measured and found to be less than 4%. Neutron fluxes for various photon field sizes ranging from 5 X 5 cm to 30 X 30 cm have been measured. The fast-neutron profiles were observed to have rounded edges and the thermal fluxes were found to be relatively uniform. In the central part of the x-ray beam, the ratio of neutron dose equivalent to photon absorbed dose was found to be between 0.2% and 0.5%. Outside of the photon field, the ratio of neutron dose equivalent to the central-axis photon absorbed dose was 0.12%.

  11. A fundamental study on hyper-thermal neutrons for neutron capture therapy.

    Science.gov (United States)

    Sakurai, Y; Kobayashi, T; Kanda, K

    1994-12-01

    The utilization of hyper-thermal neutrons, which have an energy spectrum with a Maxwellian distribution at a higher temperature than room temperature (300 K), was studied in order to improve the thermal neutron flux distribution at depth in a living body for neutron capture therapy. Simulation calculations were carried out using a Monte Carlo code 'MCNP-V3' in order to investigate the characteristics of hyper-thermal neutrons, i.e. (i) depth dependence of the neutron energy spectrum, and (ii) depth distribution of the reaction rate in a water phantom for materials with 1/v neutron absorption. It is confirmed that hyper-thermal neutron irradiation can improve the thermal neutron flux distribution in the deeper areas in a living body compared with thermal neutron irradiation. When hyper-thermal neutrons with a 3000 K Maxwellian distribution are incident on a body, the reaction rates of 1/v materials such as 14N, 10B etc are about twice that observed for incident thermal neutrons at 300 K, at a depth of 5 cm. The limit of the treatable depth for tumours having 30 ppm 10B is expected to be about 1.5 cm greater by utilizing hyper-thermal neutrons at 3000 K compared with the incidence of thermal neutrons at 300 K.

  12. Thermal neutron imaging using microchannel plates

    Science.gov (United States)

    Fraser, George W.; Pearson, James F.; Al-Horayess, O. S.; Feller, W. Bruce; Cook, Lee M.

    1993-02-01

    Microchannel plates (MCPs) are compact electron multipliers of high gain, widely used for the high resolution imaging of charged particles and photons. In this paper, we consider the use of lead glass MCPs for the imaging of thermal neutrons. Two contrasting techniques are described. The first method involves direct neutron detection within a special channel plate structure containing lithium and/or boron. We review the constraints of glass chemistry on the attainable lithium oxide and boron oxide fractions and, hence, on the maximum neutron detection efficiency. The second method involves the detection, using MCPs of standard glass composition, of the internal conversion electrons from a thin gadolinium foil. We present the first measurements of the detection efficiency, pulse height resolution and imaging properties of a pulse-counting MCP/Gd detector system.

  13. Measurements of gamma dose and thermal neutron fluence in phantoms exposed to a BNCT epithermal beam with TLD-700.

    Science.gov (United States)

    Gambarini, G; Magni, D; Regazzoni, V; Borroni, M; Carrara, M; Pignoli, E; Burian, J; Marek, M; Klupak, V; Viererbl, L

    2014-10-01

    Gamma dose and thermal neutron fluence in a phantom exposed to an epithermal neutron beam for boron neutron capture therapy (BNCT) can be measured by means of a single thermoluminescence dosemeter (TLD-700). The method exploits the shape of the glow curve (GC) and requires the gamma-calibration GC (to obtain gamma dose) and the thermal-neutron-calibration GC (to obtain neutron fluence). The method is applicable for BNCT dosimetry in case of epithermal neutron beams from a reactor because, in most irradiation configurations, thermal neutrons give a not negligible contribution to the TLD-700 GC. The thermal neutron calibration is not simple, because of the impossibility of having thermal neutron fields without gamma contamination, but a calibration method is here proposed, strictly bound to the method itself of dose separation.

  14. Neutron field features in a calibration hall

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R. [Universidad Autonoma de Zacatecas, A.P. 336, 98000 Zacatecas (Mexico)]. E-mail: rvega@cantera.reduaz.mx; Gallego, E.; Lorente, A. [Nuclear Engineering Department, Universidad Politecnica de Madrid C/Jose Gutierrez Abascal, 2, E-28006- Madrid (Spain)

    2004-07-01

    A new source facility ({sup 241} Am-Be) has been installed in a large size bunker-type room. To characterize the neutron fields in the facility, detailed calculations have been made with MCNP-4C, showing the different components of the neutron radiation reaching the reference points (direct, in scattered, backscattered). The contribution from neutrons scattered in the walls to the total ambient dose equivalent remains reasonably low (< 10%) in the reference points. Additionally, spectra measurements have been performed with a Bonner spheres spectrometer with a {sup 6}LiI(Eu) scintillator (0.4 cm 0 x 0.4 cm), UTA4 response matrix and BUNKIUT unfolding code. The calculated and experimentally obtained spectra are compared, with small differences found in the epithermal and thermal region, attributable to the concrete composition used in the calculations. The H*(10) rate has been determined from the spectra, and then compared to the reading of an active dosemeter (LB 6411), with differences found lower than 8%. (Author)

  15. Storage phosphors for thermal neutron detection

    CERN Document Server

    Sidorenko, A V; Dorenbos, P; Le Masson, N J M; Rodnyi, P A; Eijk, C W E; Berezovskaya, I V; Dotsenko, V P

    2002-01-01

    The commercial BaFBr:Eu sup 2 sup +centre dot Gd sub 2 O sub 3 image plate (IP) is used nowadays for thermal neutron detection. However, it is rather sensitive to gamma-ray background, which can deteriorate the image quality. We focused our research on the development of new types of storage phosphors with the general formula M sub 2 B sub 5 O sub 9 Br:Ce sup 3 sup + (M=Sr, Ca). Neutron detection is based on the sup 1 sup 0 B(n,alpha) reaction. The advantages of this system are the low Z sub e sub f sub f , and the 40 times higher energy deposition resulting from the neutron capture reaction in comparison with that in the commercial IP. Here we present storage and spectroscopic properties of a series of newly synthesized haloborates. Comparative measurements with commercial IPs were done under neutron and beta irradiation. A satisfying light output of optically stimulated luminescence was achieved upon neutron irradiation.

  16. Measurement of thermal neutron capture cross section

    CERN Document Server

    Huang Xiao Long; LuHanLin; Yu Wei Xiang; Zhao Wen Rong

    2001-01-01

    The thermal neutron capture cross sections of sup 7 sup 1 Ga(n, gamma) sup 7 sup 2 Ga, sup 9 sup 4 Zr(n, gamma) sup 9 sup 5 Zr and sup 1 sup 9 sup 1 Ir(n, gamma) sup 1 sup 9 sup 2 Ir sup m sup 1 sup + sup g sup , sup m sup 2 reactions were measured by using activation method and compared with other measured data. Meanwhile the half-life of sup 7 sup 2 Ga was also measured. The samples were irradiated with the neutron in the thermal column of heavy water reactor of China Institute of Atomic Energy. The activities of the reaction products were measured by well-calibrated Ge(Li) detector

  17. Cell death following thermal neutron exposure

    Energy Technology Data Exchange (ETDEWEB)

    Paterson, L.C. [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada); Atanackovic, J. [Ontario Power Generation, Toronto, Ontario (Canada); Boyer, C. [Canadian Neutron Beam Centre, Chalk River, Ontario (Canada); El-Jaby, S.; Priest, N.D. [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada); Seymour, C.B.; Boreham, D.R. [McMaster Univ., Hamilton, Ontario (Canada); Richardson, R.B. [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada)

    2014-07-01

    When individuals are exposed to unknown external ionizing radiation, it is desirable to have the means to assess both the absorbed dose received (Gy) and the radiation quality. Yet, conventional biodosimetry techniques, specifically the dicentric chromosome assay, cannot differentiate between the damage caused by high- and low-linear energy transfer (LET) exposures. Frequencies of apoptosis and necrosis, may provide an alternative method that assesses both the absorbed dose and radiation quality after unknown exposures. For this preliminary study, human lymphocytes were irradiated with {sup 60}Co gamma rays and thermal neutrons. Both apoptosis and necrosis increased with increasing gamma dose. In contrast, no dose-response was observed following thermal neutron exposure at doses up to 2.61 Gy. (author)

  18. Design of the thermal neutron detection system for CJPL-II

    Science.gov (United States)

    Zeng, Zhao-Ming; Gong, Hui; Li, Jian-Min; Yue, Qian; Zeng, Zhi; Cheng, Jian-Ping

    2017-05-01

    A low background thermal neutron flux detection system has been designed to measure the ambient thermal neutron flux of the second phase of the China Jinping Underground Laboratory (CJPL-II), right after completion of the rock bolting work. A 3He proportional counter tube combined with an identical 4He proportional counter tube was employed as the thermal neutron detector, which has been optimised in energy resolution, wall effect and radioactivity of construction materials for low background performance. The readout electronics were specially designed for long-term stable operation and easy maintenance in an underground laboratory under construction. The system was installed in Lab Hall No. 3 of CJPL-II and accumulated data for about 80 days. The ambient thermal neutron flux was determined under the assumption that the neutron field is fully thermalized, uniform and isotropic at the measurement position. Supported by National Natural Science Foundation of China (11475094)

  19. A novel detector assembly for detecting thermal neutrons, fast neutrons and gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Cester, D., E-mail: davide.cester@gmail.com [Dipartimento di Fisica ed Astronomia dell' Università di Padova, Via Marzolo 8, I-35131 Padova (Italy); Lunardon, M.; Moretto, S. [Dipartimento di Fisica ed Astronomia dell' Università di Padova, Via Marzolo 8, I-35131 Padova (Italy); INFN Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy); Nebbia, G. [INFN Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy); Pino, F. [Dipartimento di Fisica ed Astronomia dell' Università di Padova, Via Marzolo 8, I-35131 Padova (Italy); Sajo-Bohus, L. [Dipartimento di Fisica ed Astronomia dell' Università di Padova, Via Marzolo 8, I-35131 Padova (Italy); Laboratorio de Fisica Nuclear, Universidad Simon Bolivar, Apartado 89000, 1080 A Caracas (Venezuela, Bolivarian Republic of); Stevanato, L.; Bonesso, I.; Turato, F. [Dipartimento di Fisica ed Astronomia dell' Università di Padova, Via Marzolo 8, I-35131 Padova (Italy)

    2016-09-11

    A new composite detector has been developed by combining two different commercial scintillators. The device has the capability to detect gamma rays as well as thermal and fast neutrons; the signal discrimination between the three types is performed on-line by means of waveform digitizers and PSD algorithms. This work describes the assembled detector and its discrimination performance to be employed in the applied field.

  20. Evolution of Neutron Star Magnetic Fields

    Indian Academy of Sciences (India)

    Dipankar Bhattacharya

    2002-03-01

    This paper reviews the current status of the theoretical models of the evolution of the magnetic fields of neutron stars other than magnetars. It appears that the magnetic fields of neutron stars decay significantly only if they are in binary systems. Three major physical models for this, namely spindown-induced flux expulsion, ohmic evolution of crustal field and diamagnetic screening of the field by accreted plasma, are reviewed.

  1. Neutron Field Measurements in Phantom with Foil Activation Methods.

    Science.gov (United States)

    1986-11-29

    jI25 Ii III uumu ullli~ S....- - Lb - w * .qJ’ AD-A 192 122 ulJ. IL (pj DNA-TR-87- 10 N EUTRON FIELD MEASUREMENTS IN PHANTOM WITH FOIL ACTIVATION...SAND II Measurements in Phantom 6 4 The 5-Foil Neutron Dosimetry Method 29 5 Comparison of SAND II and Simple 5-Foil Dosimetry Method 34 6 Thermal ...quite reasonable. The monkey phantom spectrum differs from the NBS U-235 fission spectrum in that the former has a I/E tail plus thermal -neutron peak

  2. Study of thermal neutron capture by /sup 32/S

    Energy Technology Data Exchange (ETDEWEB)

    Taichang, G.; Zongren, S.; Xiantang, Z.; Guohua, L.; Dazhao, D.

    1985-01-15

    The thermal neutron capture by /sup 32/S has been studied using a 140 cm/sup 3/ Ge(Li) detector at the thermal column of the heavy water moderated reactor at Institute of Atomic Energy. The thermal neutron flux at sample is 2 x 10/sup 6/n/cm/sup 2/-sec and the cadmium ratio (for gold) is 200.

  3. CR-39 detector based thermal neutron flux measurements, in the photo neutron project

    Energy Technology Data Exchange (ETDEWEB)

    Mameli, A.; Greco, F.; Fidanzio, A. [U.O. di Fisica Sanitaria Policlinico A. Gemelli, Universita Cattolica S. Cuore, Roma (Italy); Fusco, V. [U.O. di Radioterapia, Centro di Riferimento Oncologico della Basilicata, CROB Rionero Pz (Italy); Cilla, S.; D' Onofrio, G.; Grimaldi, L.; Augelli, B.G. [U.O. di Fisica Sanitaria, Centro di Ricerca e Formazione ad Alta Tecnologia nelle Scienze Biomediche dell' Universita Cattolica S. Cuore, Campobasso (Italy); Giannini, G.; Bevilacqua, R.; Totaro, P. [Dipartimento di Fisica-Universita di Trieste e INFN Sez Trieste, Padriciano, Trieste (Italy); Tommasino, L. [Consultant, Via Cassia 1727, 00123 Roma (Italy); Azario, L. [Istituto di Fisica, Universita Cattolica del S. Cuore, Roma (Italy); Piermattei, A. [Istituto di Fisica, Universita Cattolica del S. Cuore, Roma (Italy)], E-mail: a.piermattei@rm.unicatt.it

    2008-08-15

    PhoNeS (photo neutron source) is a project aimed at the production and moderation of neutrons by exploiting high energy linear accelerators, currently used in radiotherapy. A feasibility study has been carried out with the scope in mind to use the high energy photon beams from these accelerators for the production of neutrons suitable for boron neutron capture therapy (BNCT). Within these investigations, it was necessary to carry out preliminary measurements of the thermal neutron component of neutron spectra, produced by the photo-conversion of X-ray radiotherapy beams supplied by three LinAcs: 15 MV, 18 MV and 23 MV. To this end, a simple passive thermal neutron detector has been used which consists of a CR-39 track detector facing a new type of boron-loaded radiator. Once calibrated, this passive detector has been used for the measurement of both the thermal neutron component and the cadmium ratio of different neutron spectra. In addition, bubble detectors with a response highly sensitive to thermal neutrons have also been used. Both thermal neutron detectors are simple to use, very compact and totally insensitive to low-ionizing radiation such as electrons and X-rays. The resultant thermal neutron flux was above 10{sup 6} n/cm{sup 2}s and the cadmium ratio was no greater than 15 for the first attempt of photo-conversion of X-ray radiotherapy beams.

  4. Boron-10 layers, Neutron Reflectometry and Thermal Neutron Gaseous Detectors

    CERN Document Server

    Piscitelli, Francesco

    2014-01-01

    Nowadays neutron facilities are going toward higher fluxes, e.g. the European Spallation Source (ESS) in Lund (Sweden), and this translates into a higher demand in the instrument performances. Because of its favorable properties,He-3 has been the main actor in thermal neutron detection for years. Starting in about 2001 the He-3 stockpile has been declining. The world is now experiencing the shortage of He-3. This makes the construction of large area detectors (several squared meters) not realistic anymore. A way to reduce the He-3 demand for those applications is to move users to alternative technologies, such as Boron-10. Although it is absolutely necessary to replace He-3 for large area applications, this is not the main issue for what concerns small area detectors for which the research is focused on improving their performances. Some technologies appear promising, though implementation would likely present technical challenges. There are several aspects that must be investigated in order to validate those...

  5. Neutron interferometry constrains dark energy chameleon fields

    Directory of Open Access Journals (Sweden)

    H. Lemmel

    2015-04-01

    Full Text Available We present phase shift measurements for neutron matter waves in vacuum and in low pressure Helium using a method originally developed for neutron scattering length measurements in neutron interferometry. We search for phase shifts associated with a coupling to scalar fields. We set stringent limits for a scalar chameleon field, a prominent quintessence dark energy candidate. We find that the coupling constant β is less than 1.9×107 for n=1 at 95% confidence level, where n is an input parameter of the self-interaction of the chameleon field φ inversely proportional to φn.

  6. Magnetic field evolution in neutron stars

    Science.gov (United States)

    Castillo, F.; Reisenegger, A.; Valdivia, J. A.

    2017-07-01

    Neutron stars contain the strongest magnetic fields known in the Universe. Using numerical simulations restricted to axially symmetric geometry, we study the long-term evolution of the magnetic field in the interior of an isolated neutron star under the effect of ambipolar diffusion, i.e. the drift of the magnetic field and the charged particles relative to the neutrons. We model the stellar interior as an electrically neutral fluid composed of neutrons, protons and electrons; these species can be converted into each other by weak interactions (beta decays), suffer binary collisions, and be affected by each other's macroscopic electromagnetic fields. We show that, in the restricted case of pure ambipolar diffusion, neglecting weak interactions, the magnetic fields evolves towards a stable MHD equilibria configuration, in the timescales analytically expected.

  7. 6Li foil thermal neutron detector

    Energy Technology Data Exchange (ETDEWEB)

    Ianakiev, Kiril D [Los Alamos National Laboratory; Swinhoe, Martyn T [Los Alamos National Laboratory; Favalli, Andrea [Los Alamos National Laboratory; Chung, Kiwhan [Los Alamos National Laboratory; Macarthur, Duncan W [Los Alamos National Laboratory

    2010-01-01

    In this paper we report on the design of a multilayer thermal neutron detector based on {sup 6}Li reactive foil and thin film plastic scintillators. The {sup 6}Li foils have about twice the intrinsic efficiency of {sup 10}B films and about four times higher light output due to a unique combination of high energy of reaction particles, low self absorption, and low ionization density of tritons. The design configuration provides for double sided readout of the lithium foil resulting in a doubling of the efficiency relative to a classical reactive film detector and generating a pulse height distribution with a valley between neutron and gamma signals similar to {sup 3}He tubes. The tens of microns thickness of plastic scintillator limits the energy deposited by gamma rays, which provides the necessary neutron/gamma discrimination. We used MCNPX to model a multilayer Li foil detector design and compared it with the standard HLNCC-II (18 {sup 3}He tubes operated at 4 atm). The preliminary results of the {sup 6}Li configuration show higher efficiency and one third of the die-away time. These properties, combined with the very short dead time of the plastic scintillator, offer the potential of a very high performance detector.

  8. Thermal neutron capture gamma-rays

    Energy Technology Data Exchange (ETDEWEB)

    Tuli, J.K.

    1983-01-01

    The energy and intensity of gamma rays as seen in thermal neutron capture are presented. Only those (n,..cap alpha..), E = thermal, reactions for which the residual nucleus mass number is greater than or equal to 45 are included. These correspond to evaluations published in Nuclear Data Sheets. The publication source data are contained in the Evaluated Nuclear Structure Data File (ENSDF). The data presented here do not involve any additional evaluation. Appendix I lists all the residual nuclides for which the data are included here. Appendix II gives a cumulated index to A-chain evaluations including the year of publication. The capture gamma ray data are given in two tables - the Table 1 is the list of all gamma rays seen in (n,..gamma..) reaction given in the order of increasing energy; the Table II lists the gamma rays according to the nuclide.

  9. Development of neutron calibration field using accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Mamoru [Tohoku Univ., Cyclotron and Radioisotope Center, Sendai, Miyagi (Japan)

    2003-03-01

    A brief summary is given on the fast neutron calibration fields for 1) 8 keV to 15 MeV range, and 2) 30-80 MeV range. The field for 8 keV to 15 MeV range was developed at the Fast Neutron Laboratory (FNL) at Tohoku University using a 4.5 MV pulsed Dynamitron accelerator and neutron production reactions, {sup 45}Sc(p, n), {sup 7}Li(p, n), {sup 3}H(p, n), D(d, n) and T(d, n). The latter 30-80 MeV fields are setup at TIARA of Takasaki Establishment of Japan Atomic Energy Research Institute, and at Cyclotron Radio Isotope Center (CYRIC) of Tohoku University using a 90 MeV AVF cyclotron and the {sup 7}Li(p, n) reaction. These fields have been applied for various calibration of neutron spectrometers and dosimeters, and for irradiation purposes. (author)

  10. Dosimetry in Thermal Neutron Irradiation Facility at BMRR

    OpenAIRE

    2016-01-01

    Radiation dosimetry for Neutron Capture Therapy (NCT) has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF) of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR). In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation f...

  11. Characteristics of the KUR Heavy Water Neutron Irradiation Facility as a neutron irradiation field with variable energy spectra

    Science.gov (United States)

    Sakurai, Yoshinori; Kobayashi, Tooru

    2000-10-01

    The Heavy Water Neutron Irradiation Facility (HWNIF) of the Kyoto University Research Reactor (KUR) was updated in March 1996, mainly for the improvement in neutron capture therapy (NCT). A striking feature of the updated facility is that the energy spectrum of the neutron beam can be controlled from almost pure thermal to epi-thermal, within 5 min by remote control under a continuous reactor operation. This feature is advantageous not only to medical science such as NCT, but also to the other research fields such as physics, engineering, biology, etc. The performance of the updated facility as a neutron irradiation field with variable energy spectra, was characterized. Thermal neutron flux, cadmium ratio, gamma-ray dose rate, etc., at the normal irradiation position for various irradiation modes were determined, mainly on the basis of the measurement using gold activation foils and thermo-luminescent dosimeters (TLDs). The emphasis was on the performance of the new neutron energy spectrum shifter and cadmium thermal neutron filter, that control the mixing ratio of thermal and epi-thermal neutrons, through the change in the heavy water thickness of the spectrum shifter and the aperture size of the cadmium filter. The evaluation of neutron energy spectra at the normal irradiation position was also performed for three representative irradiation modes, in which the neutron intensities are largest of all the irradiation modes. In addition, the irradiation characteristics of two irradiation devices, namely the Irradiation Rail Device and the Remote Patient Carrier, which were updated concurrently with the facility update, were evaluated.

  12. Applications of Neutron Bubble Dosimeters for Neutron Dose Monitoring in Mixed n-γ Fields

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>Bubble dosimeter is a promising technology in the field of neutron dosimetry. It provides real-time monitoring of neutron dose, stable energy response over wide range of neutron energy, and a very low

  13. Magneto–Thermal Evolution of Neutron Stars with Emphasis to Radio Pulsars

    Indian Academy of Sciences (India)

    U. Geppert

    2017-09-01

    The magnetic and thermal evolution of neutron stars is a very complex process with many non-linear interactions. For a decent understanding of neutron star physics, these evolutions cannot be considered isolated. A brief overview is presented, which describes the main magneto–thermal interactions that determine the fate of both isolated neutron stars and accreting ones. Special attention is devoted to the interplay of thermal and magnetic evolution at the polar cap of radio pulsars. There, a strong meridional temperature gradient is maintained over the lifetime of radio pulsars. It may be strong enough to drive thermoelectric magnetic field creation which perpetuate a toroidal magnetic field around the polar cap rim. Such a local field component may amplify and curve the poloidal surface field at the cap, forming a strong and small scale magnetic field as required for the radio emission of pulsars.

  14. Neutron-deuteron system and the photon polarization parameter at thermal neutron energies

    Science.gov (United States)

    Sadeghi, H.

    2007-04-01

    Effective field theory (EFT) is the unique, model independent and systematic low-energy version of QCD for processes involving momenta below the pion mass. A low-energy photonuclear observable in three-body systems, photon polarization parameter at thermal neutron energies is calculated by using pionless EFT up to next-to-next to leading order (NLO2). In order to make a comparative study of this model, we compared our results for photon polarization parameter with the realistic Argonne v18 two-nucleon and Urbana IX or Tucson-Melbourne three-nucleon interactions. Three-body currents give small but significant contributions to some of the observables in the neutron-deuteron radiative capture cross section at thermal neutron energies. In this formalism the three-nucleon forces are needed up to NLO2 for cut-off independent results. Our result converges order by order in low energy expansion and also cut-off independent at this order.

  15. Neutron-Deuteron System and Photon Polarization Parameter at Thermal Neutron Energies

    CERN Document Server

    Sadeghi, H

    2007-01-01

    Effective Field Theory(EFT) is, the unique, model independent and systematic low-energy version of QCD for processes involving momenta below the pion mass. A low-energy photo-nuclear observable in three-body systems, photon polarization parameter at thermal neutron energies is calculated by using pionless EFT up to next-to-next to leading order(N$^2$LO). In order to make a comparative study of this model, we compared our results for photon polarization parameter with the realistic Argonne $v_{18}$ two-nucleon and Urbana IX or Tucson-Melbourne three-nucleon interactions. Three-body currents give small but significant contributions to some of the observables in the neutron-deuteron radiative capture cross section at thermal neutron energies. In this formalism the three-nucleon forces are needed up to N$^2$LO for cut-off independent results. Our result converges order by order in low energy expansion and also cut-off independent at this order.

  16. Atmospheres and radiating surfaces of neutron stars with strong magnetic fields

    CERN Document Server

    Potekhin, A Y; Chabrier, G

    2016-01-01

    We review the current status of the theory of thermal emission from the surface layers of neutron stars with strong magnetic fields $B\\sim 10^{10}-10^{15}$ G, including formation of the spectrum in a partially ionized atmosphere and at a condensed surface. In particular, we describe recent progress in modeling partially ionized atmospheres of central compact objects in supernova remnants, which may have moderately strong fields $B\\sim 10^{10}-10^{11}$ G. Special attention is given to polarization of thermal radiation emitted by a neutron star surface. Finally, we briefly describe applications of the theory to observations of thermally emitting isolated neutron stars.

  17. UCN Source at an External Beam of Thermal Neutrons

    Directory of Open Access Journals (Sweden)

    E. V. Lychagin

    2015-01-01

    Full Text Available We propose a new method for production of ultracold neutrons (UCNs in superfluid helium. The principal idea consists in installing a helium UCN source into an external beam of thermal or cold neutrons and in surrounding this source with a solid methane moderator/reflector cooled down to ~4 K. The moderator plays the role of an external source of cold neutrons needed to produce UCNs. The flux of accumulated neutrons could exceed the flux of incident neutrons due to their numerous reflections from methane; also the source size could be significantly larger than the incident beam diameter. We provide preliminary calculations of cooling of neutrons. These calculations show that such a source being installed at an intense source of thermal or cold neutrons like the ILL or PIK reactor or the ESS spallation source could provide the UCN density 105 cm−3, the production rate 107 UCN/s−1. Main advantages of such an UCN source include its low radiative and thermal load, relatively low cost, and convenient accessibility for any maintenance. We have carried out an experiment on cooling of thermal neutrons in a methane cavity. The data confirm the results of our calculations of the spectrum and flux of neutrons in the methane cavity.

  18. Introduction of Prompt Gamma Thermal Neutron Activation Analysis at CARR

    Institute of Scientific and Technical Information of China (English)

    WANG; Xing-hua; XIAO; Cai-jin; ZHANG; Gui-ying; YAO; Yong-gang; JIN; Xiang-chun; WANG; Ping-sheng; HUA; Long; NI; Bang-fa

    2013-01-01

    CARR will provide with maximal neutron flux in Asia,the third of the world.By using the high quality neutron beam and the advanced international experience,Prompt Gamma Neutron Activation Analysis(PGNAA)facility will be setup at high level.PGNAA on CARR will promote the development of nuclear analysis technology and improve Chinese status in the nuclear analysis field.

  19. Deterministic simulation of thermal neutron radiography and tomography

    Science.gov (United States)

    Pal Chowdhury, Rajarshi; Liu, Xin

    2016-05-01

    In recent years, thermal neutron radiography and tomography have gained much attention as one of the nondestructive testing methods. However, the application of thermal neutron radiography and tomography is hindered by their technical complexity, radiation shielding, and time-consuming data collection processes. Monte Carlo simulations have been developed in the past to improve the neutron imaging facility's ability. In this paper, a new deterministic simulation approach has been proposed and demonstrated to simulate neutron radiographs numerically using a ray tracing algorithm. This approach has made the simulation of neutron radiographs much faster than by previously used stochastic methods (i.e., Monte Carlo methods). The major problem with neutron radiography and tomography simulation is finding a suitable scatter model. In this paper, an analytic scatter model has been proposed that is validated by a Monte Carlo simulation.

  20. Real-time detection of fast and thermal neutrons in radiotherapy with CMOS sensors

    Science.gov (United States)

    Arbor, Nicolas; Higueret, Stephane; Elazhar, Halima; Combe, Rodolphe; Meyer, Philippe; Dehaynin, Nicolas; Taupin, Florence; Husson, Daniel

    2017-03-01

    The peripheral dose distribution is a growing concern for the improvement of new external radiation modalities. Secondary particles, especially photo-neutrons produced by the accelerator, irradiate the patient more than tens of centimeters away from the tumor volume. However the out-of-field dose is still not estimated accurately by the treatment planning softwares. This study demonstrates the possibility of using a specially designed CMOS sensor for fast and thermal neutron monitoring in radiotherapy. The 14 microns-thick sensitive layer and the integrated electronic chain of the CMOS are particularly suitable for real-time measurements in γ/n mixed fields. An experimental field size dependency of the fast neutron production rate, supported by Monte Carlo simulations and CR-39 data, has been observed. This dependency points out the potential benefits of a real-time monitoring of fast and thermal neutron during beam intensity modulated radiation therapies.

  1. Thermal neutron calibration channel at LNMRI/IRD.

    Science.gov (United States)

    Astuto, A; Salgado, A P; Leite, S P; Patrão, K C S; Fonseca, E S; Pereira, W W; Lopes, R T

    2014-10-01

    The Brazilian Metrology Laboratory of Ionizing Radiations (LNMRI) standard thermal neutron flux facility was designed to provide uniform neutron fluence for calibration of small neutron detectors and individual dosemeters. This fluence is obtained by neutron moderation from four (241)Am-Be sources, each with 596 GBq, in a facility built with blocks of graphite/paraffin compound and high-purity carbon graphite. This study was carried out in two steps. In the first step, simulations using the MCNPX code on different geometric arrangements of moderator materials and neutron sources were performed. The quality of the resulting neutron fluence in terms of spectrum, cadmium ratio and gamma-neutron ratio was evaluated. In the second step, the system was assembled based on the results obtained on the simulations, and new measurements are being made. These measurements will validate the system, and other intercomparisons will ensure traceability to the International System of Units.

  2. Research on Prompt Neutron Multiplicity Distribution at Thermal Neutrons

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>The prompt neutron multiplicity distribution as a function of mass of fission fragments ν(A) was studied using the semi-empirical method of excitation energy distributions between the two fission

  3. Experimental investigations of the neutron contamination in high-energy photon fields at medical linear accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Brunckhorst, Elin

    2009-02-26

    The scope of this thesis was to develop a device for the detection of the photoneutron dose inside the high-energy photon field. The photoneutron contamination of a Siemens PRIMUS linear accelerator was investigated in detail in its 15 MV photon mode. The experimental examinations were performed with three ionisation chambers (a tissue equivalent chamber, a magnesium chamber and a {sup 10}B-coated magnesium chamber) and two types of thermoluminescence detectors (enriched with {sup 6}Li and {sup 7}Li, respectively). The detectors have different sensitivities to photons and neutrons and their combination allows the dose separation in a mixed neutron/photon field. The application of the ionisation chamber system, as well as the present TLD system for photoneutron detection in high-energy photon beams is a new approach. The TLD neutron sensitivity was found to be too low for a measurement inside the open photon field and the further investigation focused on the ionisation chambers. The three ionisation chambers were calibrated at different photon and neutron sources and a the borated magnesium chamber showed a very high response to thermal neutrons. For a cross check of the calibration, the three chambers were also used for dose separation of a boron neutron capture therapy beam where the exact determination of the thermal neutron dose is essential. Very accurate results were achieved for the thermal neutron dose component. At the linear accelerator the chamber system was reduced to a paired chamber system utilising the two magnesium chambers, since the fast neutron component was to small to be separated. The neutron calibration of the three chambers could not be applied, instead a conversion of measured thermal neutron signal by the borated chamber to Monte Carlo simulated total neutron dose was performed. Measurements for open fields in solid water and liquid water were performed with the paired chamber system. In larger depths the neutron dose could be determined

  4. Shift-register coincidence electronics system for thermal neutron counters

    Energy Technology Data Exchange (ETDEWEB)

    Swansen, J.E.; Collinsworth, P.R.; Krick, M.S.

    1980-04-01

    An improved shift-register, coincidence-counting logic circuit, developed for use with thermal neutron well counters, is described in detail. A distinguishing feature of the circuit is its ability to operate usefully at neutron counting rates of several hundred kHz. A portable electronics package incorporating the new coincidence logic and support circuits is also described.

  5. Characterization of neutron reference fields at US Department of Energy calibration fields.

    Science.gov (United States)

    Olsher, R H; McLean, T D; Mallett, M W; Seagraves, D T; Gadd, M S; Markham, Robin L; Murphy, R O; Devine, R T

    2007-01-01

    The Health Physics Measurements Group at the Los Alamos National Laboratory (LANL) has initiated a study of neutron reference fields at selected US Department of Energy (DOE) calibration facilities. To date, field characterisation has been completed at five facilities. These fields are traceable to the National Institute for Standards and Technology (NIST) through either a primary calibration of the source emission rate or through the use of a secondary standard. However, neutron spectral variation is caused by factors such as room return, scatter from positioning tables and fixtures, source anisotropy and spectral degradation due to source rabbits and guide tubes. Perturbations from the ideal isotropic point source field may impact the accuracy of instrument calibrations. In particular, the thermal neutron component of the spectrum, while contributing only a small fraction of the conventionally true dose, can contribute a significant fraction of a dosemeter's response with the result that the calibration becomes facility-specific. A protocol has been developed to characterise neutron fields that relies primarily on spectral measurements with the Bubble Technology Industries (BTI) rotating neutron spectrometer (ROSPEC) and the LANL Bonner sphere spectrometer. The ROSPEC measurements were supplemented at several sites by the BTI Simple Scintillation Spectrometer probe, which is designed to extend the ROSPEC upper energy range from 5 to 15 MeV. In addition, measurements were performed with several rem meters and neutron dosemeters. Detailed simulations were performed using the LANL MCNPX Monte Carlo code to calculate the magnitude of source anisotropy and scatter factors.

  6. Thermal-neutron capture for A=36-44

    CERN Document Server

    Chunmei, Z

    2003-01-01

    A new evaluation has been undertaken of the level properties, prompt gamma rays and decay scheme properties of thermal neutron capture for nuclides with mass number A=36-44. The cutoff date is March 2002. This evaluation is effectively an update of the data table of the Prompt Gamma Rays from Thermal Neutron Capture as published in Atomic Data and Nuclear Data Tables 26, 511, (1981).

  7. Thermal neutron capture cross sections of tellurium isotopes

    Science.gov (United States)

    Tomandl, I.; Honzátko, J.; von Egidy, T.; Wirth, H.-F.; Belgya, T.; Lakatos, M.; Szentmiklósi, L.; Révay, Zs.; Molnár, G. L.; Firestone, R. B.; Bondarenko, V.

    2003-12-01

    New values for thermal neutron capture cross sections of the tellurium isotopes 122 Te , 124 Te , 125 Te , 126 Te , 128 Te , and 130 Te are reported. These values are based on a combination of newly determined partial γ -ray cross sections obtained from experiments on targets contained natural Te and γ intensities per capture of individual Te isotopes. Isomeric ratios for the thermal neutron capture on the even tellurium isotopes are also given.

  8. Study of the RPC-Gd as thermal neutron detector

    Institute of Scientific and Technical Information of China (English)

    QIAN Sen; WANG Yi-Fang; ZHANG Jia-Wen; LI Jin; CHEN yuan-Bo; CHEN Jin; WANG Zhi-Gang; MA Lie-Hua

    2009-01-01

    The BESⅢ RPC with Gd coating as thermal neutron detector was designed and constructed. Three prototypes were built with different techniques of producing the gadolinium converter. The performance of the cosmic ray test, the signal and the radiation spectrum were discussed in this paper. Lastly, the efficiency of one prototype with the best performance for detecting the thermal neutron was tested as 8.7%.

  9. Thermal neutron capture cross sections of tellurium isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Tomandl, I.; Honzatko, J.; von Egidy, T.; Wirth, H.-F.; Belgya, T.; Lakatos, M.; Szentmiklosi, L.; Revay, Zs.; Molnar, G.L.; Firestone, R.B.; Bondarenko, V.

    2004-03-01

    New values for thermal neutron capture cross sections of the tellurium isotopes 122Te, 124Te, 125Te, 126Te, 128Te, and 130Te are reported. These values are based on a combination of newly determined partial g-ray cross sections obtained from experiments on targets contained natural Te and gamma intensities per capture of individual Te isotopes. Isomeric ratios for the thermal neutron capture on the even tellurium isotopes are also given.

  10. Neutron matter, neutron pairing, and neutron drops based on chiral effective field theory interactions

    Energy Technology Data Exchange (ETDEWEB)

    Krueger, Thomas

    2016-10-19

    The physics of neutron-rich systems is of great interest in nuclear and astrophysics. Precise knowledge of the properties of neutron-rich nuclei is crucial for understanding the synthesis of heavy elements. Infinite neutron matter determines properties of neutron stars, a final stage of heavy stars after a core-collapse supernova. It also provides a unique theoretical laboratory for nuclear forces. Strong interactions are determined by quantum chromodynamics (QCD). However, QCD is non-perturbative at low energies and one presently cannot directly calculate nuclear forces from it. Chiral effective field theory circumvents these problems and connects the symmetries of QCD to nuclear interactions. It naturally and systematically includes many-nucleon forces and gives access to uncertainty estimates. We use chiral interactions throughout all calculation in this thesis. Neutron stars are very extreme objects. The densities in their interior greatly exceed those in nuclei. The exact composition and properties of neutron stars is still unclear but they consist mainly of neutrons. One can explore neutron stars theoretically with calculations of neutron matter. In the inner core of neutron stars exist very high densities and thus maybe exotic phases of matter. To investigate whether there exists a phase transition to such phases even at moderate densities we study the chiral condensate in neutron matter, the order parameter of chiral symmetry breaking, and find no evidence for a phase transition at nuclear densities. We also calculate the more extreme system of spin-polarised neutron matter. With this we address the question whether there exists such a polarised phase in neutron stars and also provide a benchmark system for lattice QCD. We find spin-polarised neutron matter to be an almost non-interacting Fermi gas. To understand the cooling of neutron stars neutron pairing is of great importance. Due to the high densities especially triplet pairing is of interest. We

  11. Lithium-containing scintillators for thermal neutron, fast neutron, and gamma detection

    Energy Technology Data Exchange (ETDEWEB)

    Zaitseva, Natalia P.; Carman, M. Leslie; Faust, Michelle A.

    2016-03-01

    In one embodiment, a scintillator includes a scintillator material; a primary fluor, and a Li-containing compound, where the Li-containing compound is soluble in the primary fluor, and where the scintillator exhibits an optical response signature for thermal neutrons that is different than an optical response signature for fast neutrons and gamma rays.

  12. Experimental research on the THGEM-based thermal neutron detector

    CERN Document Server

    Lei, Yang; Zhi-Jia, Sun; Ying, Zhang; Chao-Qiang, Huang; Guang-Ai, Sun; Yan-Feng, Wang; Gui-An, Yang; Hong, Xu; Yu-Guang, Xie; Yuan-Bo, Chen

    2014-01-01

    A new thermal neutron detector with the domestically produced THGEM (THick Gas Electron Multiplier) was developed as an alternative to 3He to meet the needs of the next generation of neutron facilities. One type of Au-coated THGEM was designed specifically for the neutron detection. A detector prototype had been developed and the preliminary experimental tests were presented, including the performance of the Au-coated THGEM working in the Ar/CO2 gas mixtures and the neutron imaging test with 252CF source, which would provide the reference of experimental data for the research in future.

  13. Use of Neutron Benchmark Fields for the Validation of Dosimetry Cross Sections

    Directory of Open Access Journals (Sweden)

    Griffin Patrick

    2016-01-01

    Full Text Available The evolution of validation metrics for dosimetry cross sections in neutron benchmark fields is explored. The strength of some of the metrics in providing validation evidence is examined by applying them to the 252Cf spontaneous fission standard neutron benchmark field, the 235U thermal neutron fission reference benchmark field, the ACRR pool-type reactor central cavity reference benchmark fields, and the SPR-III fast burst reactor central cavity. The IRDFF dosimetry cross section library is used in the validation study and observations are made on the amount of coverage provided to the library contents by validation data available in these benchmark fields.

  14. Development of a thermal neutron sensor for Humanitarian Demining.

    Science.gov (United States)

    Cinausero, M; Lunardon, M; Nebbia, G; Pesente, S; Viesti, G; Filippini, V

    2004-07-01

    A thermal neutron sensor prototype for Humanitarian Demining has been developed, trying to minimize cost and complexity of the system as required in such application. A (252)Cf source or a sealed-tube neutron generator is employed to produce primary fast neutrons that are thermalized in a moderator designed to optimize the neutron capture reaction yield in buried samples. A description of the sensor, including the performances of the acquisition system based on a Flash ADC card and final tests with explosive simulants are reported. A comparison of the sensor performance when using a radioactive source to that when employing a sealed-tube neutron generator is presented. Limitations and possible applications of this technique are discussed.

  15. Development of a thermal neutron sensor for Humanitarian Demining

    Energy Technology Data Exchange (ETDEWEB)

    Cinausero, M.; Lunardon, M. E-mail: lunardon@pd.infn.it; Nebbia, G.; Pesente, S.; Viesti, G.; Filippini, V

    2004-07-01

    A thermal neutron sensor prototype for Humanitarian Demining has been developed, trying to minimize cost and complexity of the system as required in such application. A {sup 252}Cf source or a sealed-tube neutron generator is employed to produce primary fast neutrons that are thermalized in a moderator designed to optimize the neutron capture reaction yield in buried samples. A description of the sensor, including the performances of the acquisition system based on a Flash ADC card and final tests with explosive simulants are reported. A comparison of the sensor performance when using a radioactive source to that when employing a sealed-tube neutron generator is presented. Limitations and possible applications of this technique are discussed.

  16. Thin Film Polymer Composite Scintillators for Thermal Neutron Detection

    Directory of Open Access Journals (Sweden)

    Andrew N. Mabe

    2013-01-01

    Full Text Available Thin film polystyrene composite scintillators containing LiF6 and organic fluors have been fabricated and tested as thermal neutron detectors. Varying fluorescence emission intensities for different compositions are interpreted in terms of the Beer-Lambert law and indicate that the sensitivity of fluorescent sensors can be improved by incorporating transparent particles with refractive index different than that of the polymer matrix. Compositions and thicknesses were varied to optimize the fluorescence and thermal neutron response and to reduce gamma-ray sensitivity. Neutron detection efficiency and neutron/gamma-ray discrimination are reported herein as functions of composition and thickness. Gamma-ray sensitivity is affected largely by changing thickness and unaffected by the amount of LiF6 in the film. The best neutron/gamma-ray discrimination characteristics are obtained for film thicknesses in the range 25–150 μm.

  17. Neutron stars and their magnetic fields

    CERN Document Server

    Reisenegger, Andreas

    2008-01-01

    Neutron stars have the strongest magnetic fields known anywhere in the Universe. In this review, I intend to give a pedagogical discussion of some of the related physics. Neutron stars exist because of Pauli's exclusion principle, in two senses: 1) It makes it difficult to squeeze particles too close together, in this way allowing a mechanical equilibrium state in the presence of extremely strong gravity. 2) The occupation of low-energy proton and electron states makes it impossible for low-energy neutrons to beta decay. A corollary of the second statement is that charged particles are necessarily present inside a neutron star, allowing currents to flow. Since these particles are degenerate, they collide very little, and therefore make it possible for the star to support strong, organized magnetic fields over long times. These show themselves in pulsars and are the most likely energy source for the high X-ray and gamma-ray luminosity ``magnetars''. I briefly discuss the possible origin of this field and some ...

  18. Study of prompt-neutron emission in thermal-neutron-induced fission of /sup 235/U

    Energy Technology Data Exchange (ETDEWEB)

    Franklyn, C.B.

    1987-01-01

    An original experiment was performed to measure the angular correlation of fission neutrons from thermal-neutron-induced fission of /sup 235/U, with respect to the light fission fragment direction, as a function of fragment mass division and neutron energy. A Monte Carlo model, with a realistic description of the fission fragment deexcitation process, was developed to simulate the observed neutron-fragment angular correlation data. Simulated neutron-fragment angular correlations displaying similar distributions with respect to the light fragment direction for different forms of neutron emission are shown to exhibit differing distributions when examined as a function of fragment mass division or neutron energy, thus illustrating the sensitivity of the experiment to the forms of neutron emission occurring in fission. A primary conclusion of the investigation was that neutron emission solely from fully accelerated fragments, whether isotropically or anisotropically emitted in the fragment center of mass system, was unable to adequately describe the observed neutron-fragment angular correlations. Simulation of the fission process with some neutron emission before or during fragment acceleration exhibited a closer correspondence with observed phenomena.

  19. Field ion source development for neutron generators

    Science.gov (United States)

    Bargsten Johnson, B.; Schwoebel, P. R.; Holland, C. E.; Resnick, P. J.; Hertz, K. L.; Chichester, D. L.

    2012-01-01

    An ion source based on the principles of electrostatic field desorption is being developed to improve the performance of existing compact neutron generators. The ion source is an array of gated metal tips derived from field electron emitter array microfabrication technology. A comprehensive summary of development and experimental activities is presented. Many structural modifications to the arrays have been incorporated to achieve higher tip operating fields, while lowering fields at the gate electrode to prevent gate field electron emission which initiates electrical breakdown in the array. The latest focus of fabrication activities has been on rounding the gate electrode edge and surrounding the gate electrode with dielectric material. Array testing results have indicated a steady progression of increased array tip operating fields with each new design tested. The latest arrays have consistently achieved fields beyond those required for the onset of deuterium desorption (˜20 V/nm), and have demonstrated the desorption of deuterium at fields up to 36 V/nm. The number of ions desorbed from an array has been quantified, and field desorption of metal tip substrate material from array tips has been observed for the first time. Gas-phase field ionization studies with ˜10,000 tip arrays have achieved deuterium ion currents of ˜50 nA. Neutron production by field ionization has yielded ˜10 2 n/s from ˜1 mm 2 of array area using the deuterium-deuterium fusion reaction at 90 kV.

  20. Field ion source development for neutron generators

    Energy Technology Data Exchange (ETDEWEB)

    Bargsten Johnson, B. [University of New Mexico, Albuquerque, NM 87131 (United States); Schwoebel, P.R., E-mail: schwoebel@chtm.unm.edu [University of New Mexico, Albuquerque, NM 87131 (United States); Holland, C.E. [SRI International, Menlo Park, CA 94025 (United States); Resnick, P.J. [Sandia National Laboratories, Albuquerque, NM 87123 (United States); Hertz, K.L. [Sandia National Laboratories, Livermore, CA 94551 (United States); Chichester, D.L. [Idaho National Laboratory, Idaho Falls, ID 83415 (United States)

    2012-01-21

    An ion source based on the principles of electrostatic field desorption is being developed to improve the performance of existing compact neutron generators. The ion source is an array of gated metal tips derived from field electron emitter array microfabrication technology. A comprehensive summary of development and experimental activities is presented. Many structural modifications to the arrays have been incorporated to achieve higher tip operating fields, while lowering fields at the gate electrode to prevent gate field electron emission which initiates electrical breakdown in the array. The latest focus of fabrication activities has been on rounding the gate electrode edge and surrounding the gate electrode with dielectric material. Array testing results have indicated a steady progression of increased array tip operating fields with each new design tested. The latest arrays have consistently achieved fields beyond those required for the onset of deuterium desorption ({approx}20 V/nm), and have demonstrated the desorption of deuterium at fields up to 36 V/nm. The number of ions desorbed from an array has been quantified, and field desorption of metal tip substrate material from array tips has been observed for the first time. Gas-phase field ionization studies with {approx}10,000 tip arrays have achieved deuterium ion currents of {approx}50 nA. Neutron production by field ionization has yielded {approx}10{sup 2} n/s from {approx}1 mm{sup 2} of array area using the deuterium-deuterium fusion reaction at 90 kV.

  1. Field Ion Source Development for Neutron Generators

    Energy Technology Data Exchange (ETDEWEB)

    B. Bargsten Johnson; P. R. Schwoebel; C. E. Holland; P. J. Resnick; K. L. Hertz; D. L. Chichester

    2012-01-01

    An ion source based on the principles of electrostatic field desorption is being developed to improve the performance of existing compact neutron generators. The ion source is an array of gated metal tips derived from field electron emitter array microfabrication technology. A comprehensive summary of development and experimental activities is presented. Many structural modifications to the arrays have been incorporated to achieve higher tip operating fields, while lowering fields at the gate electrode to prevent gate field electron emission which initiates electrical breakdown in the array. The latest focus of fabrication activities has been on rounding the gate electrode edge and surrounding the gate electrode with dielectric material. Array testing results have indicated a steady progression of increased array tip operating fields with each new design tested. The latest arrays have consistently achieved fields beyond those required for the onset of deuterium desorption ({approx}20 V/nm), and have demonstrated the desorption of deuterium at fields up to 36 V/nm. The number of ions desorbed from an array has been quantified, and field desorption of metal tip substrate material from array tips has been observed for the first time. Gas-phase field ionization studies with {approx}10,000 tip arrays have achieved deuterium ion currents of {approx}50 nA. Neutron production by field ionization has yielded {approx}10{sup 2} n/s from {approx}1 mm{sup 2} of array area using the deuterium-deuterium fusion reaction at 90 kV.

  2. EL-2 reactor: Thermal neutron flux distribution; EL-2: Repartition du flux de neutrons thermiques

    Energy Technology Data Exchange (ETDEWEB)

    Rousseau, A.; Genthon, J.P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The flux distribution of thermal neutrons in EL-2 reactor is studied. The reactor core and lattices are described as well as the experimental reactor facilities, in particular, the experimental channels and special facilities. The measurement shows that the thermal neutron flux increases in the central channel when enriched uranium is used in place of natural uranium. However the thermal neutron flux is not perturbed in the other reactor channels by the fuel modification. The macroscopic flux distribution is measured according the radial positioning of fuel rods. The longitudinal neutron flux distribution in a fuel rod is also measured and shows no difference between enriched and natural uranium fuel rods. In addition, measurements of the flux distribution have been effectuated for rods containing other material as steel or aluminium. The neutron flux distribution is also studied in all the experimental channels as well as in the thermal column. The determination of the distribution of the thermal neutron flux in all experimental facilities, the thermal column and the fuel channels has been made with a heavy water level of 1825 mm and is given for an operating power of 1000 kW. (M.P.)

  3. Experimental characterization of semiconductor-based thermal neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bedogni, R., E-mail: roberto.bedogni@lnf.infn.it [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); Bortot, D.; Pola, A.; Introini, M.V.; Lorenzoli, M. [Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano (Italy); INFN—Milano, Via Celoria 16, 20133 Milano (Italy); Gómez-Ros, J.M. [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); CIEMAT, Av. Complutense 40, 28040 Madrid (Spain); Sacco, D. [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); INAIL—DIT, Via di Fontana Candida 1, 00040 Monteporzio Catone (Italy); Esposito, A.; Gentile, A.; Buonomo, B. [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); Palomba, M.; Grossi, A. [ENEA Triga RC-1C.R. Casaccia, via Anguillarese 301, 00060 S. Maria di Galeria, Roma (Italy)

    2015-04-21

    In the framework of NESCOFI@BTF and NEURAPID projects, active thermal neutron detectors were manufactured by depositing appropriate thickness of {sup 6}LiF on commercially available windowless p–i–n diodes. Detectors with different radiator thickness, ranging from 5 to 62 μm, were manufactured by evaporation-based deposition technique and exposed to known values of thermal neutron fluence in two thermal neutron facilities exhibiting different irradiation geometries. The following properties of the detector response were investigated and presented in this work: thickness dependence, impact of parasitic effects (photons and epithermal neutrons), linearity, isotropy, and radiation damage following exposure to large fluence (in the order of 10{sup 12} cm{sup −2})

  4. Boron neutron capture therapy (BNCT). Recent aspect, a change from thermal neutron to epithermal neutron beam and a new protocol

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Yoshinobu [Dept. of Neurosurgery National Kagawa Children' s Hospital, Zentsuji, Kagawa (Japan)

    1999-08-01

    Since 1968, One-hundred seventy three patients with glioblastoma (n=81), anaplastic astrocytoma (n=44), low grade astrocytoma (n=16) or other types of tumor (n=32) were treated by boron-neutron capture therapy (BNCT) using a combination of thermal neutron and BSH in 5 reactors (HTR n=13, JRR-3 n=1, MuITR n=98, KUR n=28, JRR-2 n=33). Out of 101 patients with glioma treated by BNCT under the recent protocol, 33 (10 glioblastoma, 14 anaplastic astrocytoma, 9 low grade astrocytoma) patients lived or have lived longer than 3 years. Nine of these 33 lived or have lived longer than 10 years. According to the retrospective analysis, the important factors related to the clinical results were tumor dose radiation dose and maximum radiation dose in thermal brain cortex. The result was not satisfied as it was expected. Then, we decided to introduce mixed beams which contain thermal neutron and epithermal neutron beams. KUR was reconstructed in 1996 and developed to be available to use mixed beams. Following the shutdown of the JRR-2, JRR-4 was renewed for medical use in 1998. Both reactors have capacity to yield thermal neutron beam, epithermal neutron beam and mixed beams. The development of the neutron source lead us to make a new protocol. (author)

  5. Monitoring of the thermal neutron flux in the LSM underground laboratory

    CERN Document Server

    Rozov, S; Augier, C; Bergé, L; Benoit, A; Besida, O; Blümer, J; Broniatowski, A; Brudanin, V; Chantelauze, A; Chapellier, M; Chardin, G; Charlieux, F; Collin, S; Crauste, O; De Jesus, M; Defay, X; Di Stefano, P; Dolgorouki, Y; Domange, J; Dumoulin, L; Eitel, K; Filosofov, D; Gascon, J; Gerbier, G; Gros, M; Hannawald, M; Juillard, A; Kluck, H; Kozlov, V; Lemrani, R; Lubashevskiy, A; Marrach, C; Marnieros, S; Navick, X-F; Nones, C; Olivieri, E; Pari, P; Paul, B; Sanglard, V; Scorza, S; Semikh, S; Verdier, M-A; Vagneron, L; Yakushev, E

    2010-01-01

    This paper describes precise measurements of the thermal neutron flux in the LSM underground laboratory in proximity of the EDELWEISS-II dark matter search experiment together with short measurements at various other locations. Monitoring of the flux of thermal neutrons is accomplished using a mobile detection system with low background proportional counter filled with $^3$He. On average 75 neutrons per day are detected with a background level below 1 count per day (cpd). This provides a unique possibility of a day by day study of variations of the neutron field in a deep underground site. The measured average 4$\\pi$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is $\\Phi_{MB}=3.57\\pm0.05^{stat}\\pm0.27^{syst}\\times 10^{-6}$ neutrons/sec. We report the first experimental observation that the point-to-point thermal neutron flux at LSM varies by more than a factor two.

  6. Gamma discrimination in pillar structured thermal neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Q; Radev, R P; Conway, A M; Voss, L F; Wang, T F; Nikolic, R J; Deo, N; Cheung, C L

    2012-03-26

    Solid-state thermal neutron detectors are desired to replace {sup 3}He tube based technology for the detection of special nuclear materials. {sup 3}He tubes have some issues with stability, sensitivity to microphonics and very recently, a shortage of {sup 3}He. There are numerous solid-state approaches being investigated that utilize various architectures and material combinations. By using the combination of high-aspect-ratio silicon PIN pillars, which are 2 {micro}m wide with a 2 {micro}m separation, arranged in a square matrix, and surrounded by {sup 10}B, the neutron converter material, a high efficiency thermal neutron detector is possible. Besides intrinsic neutron detection efficiency, neutron to gamma discrimination is an important figure of merit for unambiguous signal identification. In this work, theoretical calculations and experimental measurements are conducted to determine the effect of structure design of pillar structured thermal neutron detectors including: intrinsic layer thickness, pillar height, substrate doping and incident gamma energy on neutron to gamma discrimination.

  7. Thermal Modeling and Feedback Requirements for LIFE Neutronic Simulations

    Energy Technology Data Exchange (ETDEWEB)

    Seifried, J E

    2009-07-15

    An initial study is performed to determine how temperature considerations affect LIFE neutronic simulations. Among other figures of merit, the isotopic mass accumulation, thermal power, tritium breeding, and criticality are analyzed. Possible fidelities of thermal modeling and degrees of coupling are explored. Lessons learned from switching and modifying nuclear datasets is communicated.

  8. Enhanced plastic neutron shielding for thermal and epithermal neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Palomino, L A RodrIguez; Blostein, J J; Dawidowski, J [Consejo Nacional de Investigaciones CientIficas y Tecnicas, Centro Atomico Bariloche and Instituto Balseiro, Comision Nacional de EnergIa Atomica, Universidad Nacional de Cuyo, (8400) Bariloche, Av. Bustillo 9500, S. C. de Bariloche, RIo Negro (Argentina); Cuello, G J [Institut Laue Langevin, 6, rue Jules Horowitz, F-38042 Grenoble Cedex 9 (France)], E-mail: javier@cab.cnea.gov.ar

    2008-06-15

    We describe a compound made of paraffin and boron carbide (boraffin) deviced to enhance epithermal neutron shielding. The compound is easily prepared and is specially suited to be adapted to particular surfaces. Transmission experiments show a favourable comparison with a commercial rubber-boron carbide compound in the epithermal range. A detector shielding built with this material is described and the achieved background reduction experimentally determined is shown.

  9. Experimental determination of gamma-ray discrimination in pillar-structured thermal neutron detectors under high gamma-ray flux

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Qinghui [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Conway, Adam M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Voss, Lars F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Radev, Radoslav P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Nikolić, Rebecca J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Dar, Mushtaq A. [King Saud Univ., Riyadh (Saudi Arabia); Cheung, Chin L. [Univ. of Nebraska, Lincoln, NE (United States). Dept. of Chemistry

    2015-08-04

    Silicon pillar structures filled with a neutron converter material (10B) are designed to have high thermal neutron detection efficiency with specific dimensions of 50 μm pillar height, 2 μm pillar diameter and 2 μm spacing between adjacent pillars. In this paper, we have demonstrated such a detector has a high neutron-to-gamma discrimination of 106 with a high thermal neutron detection efficiency of 39% when exposed to a high gamma-ray field of 109 photons/cm2s.

  10. Experimental determination of gamma-ray discrimination in pillar-structured thermal neutron detectors under high gamma-ray flux

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Qinghui [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Conway, Adam M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Voss, Lars F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Radev, Radoslav P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Nikolić, Rebecca J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Dar, Mushtaq A. [King Saud Univ., Riyadh (Saudi Arabia); Cheung, Chin L. [Univ. of Nebraska, Lincoln, NE (United States). Dept. of Chemistry

    2015-08-04

    Silicon pillar structures filled with a neutron converter material (10B) are designed to have high thermal neutron detection efficiency with specific dimensions of 50 μm pillar height, 2 μm pillar diameter and 2 μm spacing between adjacent pillars. In this paper, we have demonstrated such a detector has a high neutron-to-gamma discrimination of 106 with a high thermal neutron detection efficiency of 39% when exposed to a high gamma-ray field of 109 photons/cm2s.

  11. Modern Techniques for Inelastic Thermal Neutron Scattering Analysis

    Science.gov (United States)

    Hawari, A. I.

    2014-04-01

    A predictive approach based on ab initio quantum mechanics and/or classical molecular dynamics simulations has been formulated to calculate the scattering law, S(κ⇀,ω), and the thermal neutron scattering cross sections of materials. In principle, these atomistic methods make it possible to generate the inelastic thermal neutron scattering cross sections of any material and to accurately reflect the physical conditions of the medium (i.e, temperature, pressure, etc.). In addition, the generated cross sections are free from assumptions such as the incoherent approximation of scattering theory and, in the case of solids, crystalline perfection. As a result, new and improved thermal neutron scattering data libraries have been generated for a variety of materials. Among these are materials used for reactor moderators and reflectors such as reactor-grade graphite and beryllium (including the coherent inelastic scattering component), silicon carbide, cold neutron media such as solid methane, and neutron beam filters such as sapphire and bismuth. Consequently, it is anticipated that the above approach will play a major role in providing the nuclear science and engineering community with its needs of thermal neutron scattering data especially when considering new materials where experimental information may be scarce or nonexistent.

  12. Gel dosimeters as useful dose and thermal-fluence detectors in Boron Neutron Capture Therapy (BNCT)

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G.; Valente, M. [Department of Physics of the University and INFN, Via Celoria 16, I-20133 Milan (Italy); Moss, R.L.; Daquino, G.G.; Nievaart, V.A. [Joint Research Centre, Institute for Energy, P.O. Box 2, NL-1755ZG Petten, The Netherlands (Netherlands); Mariani, M.; Vanossi, E. [Department of Nuclear Engineering of Polytechnic, CESNEF, Via Ponzio, 34/3 - I-20133 Milan (Italy); Carrara, M. [Medical Physics Department, National Cancer Institute, Via Venezian 1, I-20131, Milan (Italy)

    2006-07-01

    The dosimetry method based on Fricke-Xylenol-Orange-infused gels in form of layers has shown noticeable potentiality for in-phantom or in-free-beam dose and thermal flux profiling and imaging in the high fluxes of thermal or epithermal neutrons utilised for boron neutron capture therapy (BNCT). Gel-dosimeters in form of layers give the possibility not only of obtaining spatial dose distributions but also of achieving measurements of each dose contribution in neutron fields. The discrimination of the various dose components is achieved by means of pixel-to-pixel manipulations of pairs of images obtained with gel-dosimeters having different isotopic composition. It is possible to place large dosimeters, detecting in such a way large dose images, because the layer geometry of dosimeters avoids sensitive variation of neutron transport due to the gel isotopic composition. Some results obtained after the last improvements of the method are reported. (Author)

  13. Magnetic field evolution of accreting neutron stars

    CERN Document Server

    Istomin, Ya N

    2016-01-01

    The flow of a matter, accreting onto a magnetized neutron star, is accompanied by an electric current. The closing of the electric current occurs in the crust of a neutron stars in the polar region across the magnetic field. But the conductivity of the crust along the magnetic field greatly exceeds the conductivity across the field, so the current penetrates deep into the crust down up to the super conducting core. The magnetic field, generated by the accretion current, increases greatly with the depth of penetration due to the Hall conductivity of the crust is also much larger than the transverse conductivity. As a result, the current begins to flow mainly in the toroidal direction, creating a strong longitudinal magnetic field, far exceeding an initial dipole field. This field exists only in the narrow polar tube of $r$ width, narrowing with the depth, i.e. with increasing of the crust density $\\rho$, $r\\propto \\rho^{-1/4}$. Accordingly, the magnetic field $B$ in the tube increases with the depth, $B\\propto...

  14. Electromagnetic multipole fields of neutron stars

    Science.gov (United States)

    Roberts, W. J.

    1979-01-01

    A formalism is developed for treating general multipole electromagnetic fields of neutron stars. The electric multipoles induced in a neutron star by its rotation with an arbitrary magnetic multipole at its center are presented. It is shown how to express a family of off-centered multipoles having the same l weight as an infinite array of centered multipoles of increasing l weight referred to the rotational axis. General expressions are given for the linear momentum present in the superposition of arbitrary multipole fields, and the results are combined to compute the radiation rate of linear momentum by an off-centered dipole to zeroth order in the parameter Omega x R/c. The general Deutsch (1955) solution is then rederived in a clear consistent manner, and some minor additions and corrections are provided.

  15. Thermal-neutron capture for A=26-35

    Energy Technology Data Exchange (ETDEWEB)

    Chunmei, Z.; Firestone, R.B.

    2001-06-01

    The prompt gamma-ray data of thermal- neutron captures fornuclear mass number A=26-35 had been evaluated and published in "ATOMICDATA AND NUCLEAR DATA TABLES, 26, 511 (1981)". Since that time themanyexperimental data of the thermal-neutron captures have been measuredand published. The update of the evaluated prompt gamma-ray data is verynecessary for use in PGAA of high-resolution analytical prompt gamma-rayspectroscopy. Besides, the evaluation is also very needed in theEvaluated Nuclear Structure Data File, ENSDF, because there are no promptgamma-ray data in ENSDF. The levels, prompt gamma-rays and decay schemesof thermal-neutron captures for nuclides (26Mg, 27Al, 28Si, 29Si, 30Si,31P, 32S, 33S, 34S, and 35Cl) with nuclear mass number A=26-35 have beenevaluated on the basis of all experimental data. The normalizationfactors, from which absolute prompt gamma-ray intensity can be obtained,and necessary comments are given in the text. The ENSDF format has beenadopted in this evaluation. The physical check (intensity balance andenergy balance) of evaluated thermal-neutron capture data has been done.The evaluated data have been put into Evaluated Nuclear Structure DataFile, ENSDF. This evaluation may be considered as an update of the promptgamma-ray from thermal-neutron capture data tables as published in"ATOMIC DATA AND NUCLEAR DATA TABLES, 26, 511 (1981)".

  16. Thermal-neutron capture for A=36-44

    Energy Technology Data Exchange (ETDEWEB)

    Chunmei, Z.; Firestone, R.B.

    2003-01-01

    The prompt gamma-ray data of thermal- neutron captures fornuclear mass number A=26-35 had been evaluated and published in "ATOMICDATA AND NUCLEAR DATA TABLES, 26, 511 (1981)". Since that time the manyexperimental data of the thermal-neutron captures have been measured andpublished. The update of the evaluated prompt gamma-ray data is verynecessary for use in PGAA of high-resolution analytical prompt gamma-rayspectroscopy. Besides, the evaluation is also very needed in theEvaluated Nuclear Structure Data File, ENSDF, because there are no promptgamma-ray data in ENSDF. The levels, prompt gamma-rays and decay schemesof thermal-neutron captures fornuclides (26Mg, 27Al, 28Si, 29Si, 30Si,31P, 32S, 33S, 34S, and 35Cl) with nuclear mass number A=26-35 have beenevaluated on the basis of all experimental data. The normalizationfactors, from which absolute prompt gamma-ray intensity can be obtained,and necessary comments are given in the text. The ENSDF format has beenadopted in this evaluation. The physical check (intensity balance andenergy balance) of evaluated thermal-neutron capture data has been done.The evaluated data have been put into Evaluated Nuclear Structure DataFile, ENSDF. This evaluation may be considered as an update of the promptgamma-ray from thermal-neutron capture data tables as published in"ATOMIC DATA AND NUCLEAR DATA TABLES, 26, 511 (1981)".

  17. Isotopic characterization and thermal neutron flux determination of a PuBe neutron source.

    Science.gov (United States)

    Purty, Ravi Ankit; Akanchha; Prasad, Shikha

    2017-07-01

    The Indian Institute of Technology Kanpur (IIT Kanpur) possesses a PuBe neutron source facility with an initial activity of 5 Ci, dated September 1966 (nearly 50 years ago). An understanding of the present activity and the rate of its change will allow implementation of proper radiological safety procedures and future radiological safety planning. Knowing the absolute neutron flux will help us in future neutron activation studies. These details are also important to ensure proper security precautions. In our work, we attempt to identify the isotopic composition to determine the rate of change of the source and the absolute thermal neutron flux of plutonium beryllium (PuBe) sample at IIT Kanpur. We have used gamma-ray spectroscopy for determining the isotopic composition of the PuBe neutron source. After utilizing gamma-ray spectroscopy it is found that the source is composed of (239)Pu and a small amount of (241)Am is present as an impurity. The mass ratio of (241)Am to (239)Pu is found to be approximately 18.1µg/g with an uncertainty of 1.39%. Delayed gamma neutron activation analysis (DGNAA) is used to determine the thermal neutron flux of the same PuBe neutron source using copper, cobalt, nickel and cadmium samples. The average thermal neutron flux as calculated from DGNAA is approximately 1.27×10(3)n/(cm(2)-s) at 1cm above the PuBe neutron source. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. PADC Detected External Neutron Field by Nuclear Tracks at RFX-mod

    Directory of Open Access Journals (Sweden)

    W. Gonzalez

    2014-08-01

    Full Text Available Measured neutron signals relevant for plasma diagnostics on Reversed Field pinch eXperiment, RFX-mod, are obtained by nuclear track methodology with PADC-NTD’s. This technique provides the external neutron field values around the RFX-mod installation during pulsed operation. Charged particles from (n, p and (n, α reactions are related to formed latent tracks. These are etched in a thermoregulated water bath with a 6.25M, KOH solution at 60o C. Observed tracks were analyzed to determine track density from which neutron fluence spatial values should be derived. Results indicate that the neutron density in the surrounding environment change at most 40%. The epithermal component is 60% higher than that corresponding to the thermal region. The estimated neutron fluence for the whole experiment is 7.5×1010 neutrons cm2 /s.

  19. Measurement of neutron dose equivalent to proton therapy patients outside of the proton radiation field

    CERN Document Server

    Yan, X; Köhler, A; Newhauser, W D

    2002-01-01

    Measurements of neutron dose equivalent values and neutron spectral fluences close to but outside of the therapeutic proton radiation field are presented. The neutron spectral fluences were determined at five locations with Bonner sphere measurements and established by unfolding techniques. More than 50 additional neutron dose equivalent values were measured with LiI and BF sub 3 thermal neutron detectors surrounded by a 25 cm polyethylene moderating sphere. For a large-field treatment, typical values of neutron dose equivalent per therapeutic proton absorbed dose, H/D, at 50 cm distance from isocenter, range from 1 mSv/Gy (at 0 deg.with respect to the proton beam axis) to 5 mSv/Gy (at 90 deg.). Experiments reveal that H/D varies significantly with the treatment technique, e.g., patient orientation, proton beam energy, and range-modulation. The relative uncertainty in H/D values is approximately 40% (one standard deviation).

  20. Dosimetry in Thermal Neutron Irradiation Facility at BMRR

    Directory of Open Access Journals (Sweden)

    Hu J.-P.

    2016-01-01

    Full Text Available Radiation dosimetry for Neutron Capture Therapy (NCT has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR. In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation facility, a series of innovative designs and major modifications made to enhance the beam intensity and to ease the experimental sampling at BMRR were performed; including (1 in-core fuel addition to increase source strength and balance flux of neutrons towards two ports, (2 out of core moderator remodeling, done by replacing thicker D2O tanks at graphite-shutter interfacial areas, to expedite neutron thermalization, (3 beam shutter upgrade to reduce strayed neutrons and gamma dose, (4 beam collimator redesign to optimize the beam flux versus dose for animal treatment, (5 beam port shielding installation around the shutter opening area (lithium-6 enriched polyester-resin in boxes, attached with polyethylene plates to reduce prompt gamma and fast neutron doses, (6 sample holder repositioning to optimize angle versus distance for a single organ or whole body irradiation, and (7 holder wall buildup with neutron reflector materials to increase dose and dose rate from scattered thermal neutrons. During the facility upgrade, reactor dosimetry was conducted using thermoluminescent dosimeters TLD for gamma dose estimate, using ion chambers to confirm fast neutron and gamma dose rate, and by the activation of gold-foils with and without cadmium-covers, for fast and thermal neutron flux determination. Based on the combined effect from the size and depth of tumor cells and the location and geometry of dosimeters, the measured flux from cadmium-difference method was 4–7

  1. Dosimetry in Thermal Neutron Irradiation Facility at BMRR

    Energy Technology Data Exchange (ETDEWEB)

    Hu, J. P. [Brookhaven National Lab. (BNL), Upton, NY (United States); Holden, N. E. [Brookhaven National Lab. (BNL), Upton, NY (United States); Reciniello, R. N.

    2014-05-23

    Radiation dosimetry for Neutron Capture Therapy (NCT) has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF) of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR). In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation facility, a series of innovative designs and major modifications made to enhance the beam intensity and to ease the experimental sampling at BMRR were performed; including (1) in-core fuel addition to increase source strength and balance flux of neutrons towards two ports, (2) out of core moderator remodeling, done by replacing thicker D2O tanks at graphite-shutter interfacial areas, to expedite neutron thermalization, (3) beam shutter upgrade to reduce strayed neutrons and gamma dose, (4) beam collimator redesign to optimize the beam flux versus dose for animal treatment, (5) beam port shielding installation around the shutter opening area (lithium-6 enriched polyester-resin in boxes, attached with polyethylene plates) to reduce prompt gamma and fast neutron doses, (6) sample holder repositioning to optimize angle versus distance for a single organ or whole body irradiation, and (7) holder wall buildup with neutron reflector materials to increase dose and dose rate from scattered thermal neutrons. During the facility upgrade, reactor dosimetry was conducted using thermoluminescent dosimeters TLD for gamma dose estimate, using ion chambers to confirm fast neutron and gamma dose rate, and by the activation of gold-foils with and without cadmium-covers, for fast and thermal neutron flux determination. Based on the combined effect from the size and depth of tumor cells and the location and geometry of dosimeters, the measured flux from cadmium-difference method was 4 - 7

  2. Dosimetry in Thermal Neutron Irradiation Facility at BMRR

    Science.gov (United States)

    Hu, J.-P.; Holden, N. E.; Reciniello, R. N.

    2016-02-01

    Radiation dosimetry for Neutron Capture Therapy (NCT) has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF) of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR). In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation facility, a series of innovative designs and major modifications made to enhance the beam intensity and to ease the experimental sampling at BMRR were performed; including (1) in-core fuel addition to increase source strength and balance flux of neutrons towards two ports, (2) out of core moderator remodeling, done by replacing thicker D2O tanks at graphite-shutter interfacial areas, to expedite neutron thermalization, (3) beam shutter upgrade to reduce strayed neutrons and gamma dose, (4) beam collimator redesign to optimize the beam flux versus dose for animal treatment, (5) beam port shielding installation around the shutter opening area (lithium-6 enriched polyester-resin in boxes, attached with polyethylene plates) to reduce prompt gamma and fast neutron doses, (6) sample holder repositioning to optimize angle versus distance for a single organ or whole body irradiation, and (7) holder wall buildup with neutron reflector materials to increase dose and dose rate from scattered thermal neutrons. During the facility upgrade, reactor dosimetry was conducted using thermoluminescent dosimeters TLD for gamma dose estimate, using ion chambers to confirm fast neutron and gamma dose rate, and by the activation of gold-foils with and without cadmium-covers, for fast and thermal neutron flux determination. Based on the combined effect from the size and depth of tumor cells and the location and geometry of dosimeters, the measured flux from cadmium-difference method was 4-7% lower than

  3. Radiation Fields in the Vicinity of Compact Accelerator Neutron Generators

    Energy Technology Data Exchange (ETDEWEB)

    David L. Chichester; Brandon W. Blackburn; Augustine J. Caffrey

    2006-10-01

    Intense pulsed radiation fields emitted from sealed tube neutron generators provide a challenge for modern health physics survey instrumentation. The spectral sensitivity of these survey instruments requires calibration under realistic field conditions while the pulsed emission characteristics of neutron generators can vary from conditions of steady-state operation. As a general guide for assessing radiological conditions around neutron generators, experiments and modeling simulations have been performed to assess radiation fields near DD and DT neutron generators. The presence of other materials and material configurations can also have important effects on the radiation dose fields around compact accelerator neutron generators.

  4. Targets for bulk hydrogen analysis using thermal neutrons

    CERN Document Server

    Csikai, J; Buczko, C M

    2002-01-01

    The reflection property of substances can be characterized by the reflection cross-section of thermal neutrons, sigma subbeta. A combination of the targets with thin polyethylene foils allowed an estimation of the flux depression of thermal neutrons caused by a bulk sample containing highly absorbing elements or compounds. Some new and more accurate sigma subbeta values were determined by using the combined target arrangement. For the ratio, R of the reflection and the elastic scattering cross-sections of thermal neutrons, R=sigma subbeta/sigma sub E sub L a value of 0.60+-0.02 was found on the basis of the data obtained for a number of elements from H to Pb. Using this correlation factor, and the sigma sub E sub L values, the unknown sigma subbeta data can be deduced. The equivalent thicknesses, to polyethylene or hydrogen, of the different target materials were determined from the sigma subbeta values.

  5. System and plastic scintillator for discrimination of thermal neutron, fast neutron, and gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Zaitseva, Natalia P.; Carman, M. Leslie; Faust, Michelle A.; Glenn, Andrew M.; Martinez, H. Paul; Pawelczak, Iwona A.; Payne, Stephen A.

    2017-05-16

    A scintillator material according to one embodiment includes a polymer matrix; a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount of 3 wt % or more; and at least one component in the polymer matrix, the component being selected from a group consisting of B, Li, Gd, a B-containing compound, a Li-containing compound and a Gd-containing compound, wherein the scintillator material exhibits an optical response signature for thermal neutrons that is different than an optical response signature for fast neutrons and gamma rays. A system according to one embodiment includes a scintillator material as disclosed herein and a photodetector for detecting the response of the material to fast neutron, thermal neutron and gamma ray irradiation.

  6. NEUTRON CAPTURE GAMMA RAY FIELD WITH ENERGY TO 10 MeV FOR METROLOGICAL SUPPORT OF RADIATION PROTECTION DEVICES

    Directory of Open Access Journals (Sweden)

    D. I. Komar

    2016-01-01

    Full Text Available Medical, and technological linear particle accelerators, and nuclear reactors are vastly widespread worldwide today. These facility generate fields of secondary gamma radiation with energy to 10 MeV. Therefore, we have a need to calibrate spectrometric and dosimetric ionization measurement instruments for the energies to 10 MeV. The aim of this work is to determine possibility to use thermal neutron collimator of АТ140 Neutron Calibration Facility with 238Pu-Be fast neutron source (IBN-8-6 for this. Below 3 MeV we use a set of point gamma standard spectrometry sources OSGI. We can acquire gamma rays with energies above 3 MeV using radioactive thermal neutron capture on target, i.e. (n, γ-nuclear reaction. We can use neutron capture gamma-ray from titanium target (to 7 MeV or nickel target (to 10 MeV situated in thermal neutron field for calibration. We can use thermal neutron collimator of АТ140 Neutron Calibration Facility with 238Pu-Be fast neutron source (IBN-8-6 for slowing down neutrons from radionuclide fast neutron sources to thermal energies in polyethylene. Thermal neutron collimator forms a beam from radionuclide source with a significant amount of neutrons with thermal energies. We placed Ti and Ni targets in collimator’s canal. We got experimental spectral data on detection unit BDKG-19M NaI(Tl 63 × 160 mm with nonlinear channel-energy conversion characteristic in range to 10 MeV. For additional filtration we proposed to use polyethylene neutron reflector and lead discs. We experimentally determined that placement of lead discs in collimator in front of the target allows to filter all spectrum while insignificantly weakening target’s emission. Using theoretical and experimental data we proved the ability to calibrate gamma-ray spectrometers in the range to 10 MeV. 

  7. Thermal Neutron Capture onto the Stable Tungsten Isotopes

    Directory of Open Access Journals (Sweden)

    Nichols A.

    2012-02-01

    Full Text Available Thermal neutron-capture measurements of the stable tungsten isotopes have been carried out using the guided thermal-neutron beam at the Budapest Reactor. Prompt singles spectra were collected and analyzed using the HYPERMET γ-ray analysis software package for the compound tungsten systems 183W, 184W, and 187W, prepared from isotopically-enriched samples of 182W, 183W, and 186W, respectively. These new data provide both confirmation and new insights into the decay schemes and structure of the tungsten isotopes reported in the Evaluated Gamma-ray Activation File based upon previous elemental analysis. The experimental data have also been compared to Monte Carlo simulations of γ-ray emission following the thermal neutron-capture process using the statistical-decay code DICEBOX. Together, the experimental cross sections and modeledfeeding contribution from the quasi continuum, have been used to determine the total radiative thermal neutron-capture cross sections for the tungsten isotopes and provide improved decay-scheme information for the structural- and neutron-data libraries.

  8. Dose Determination using alanine detectors in a Mixed Neutron and Gamma Field for Boron Neutron Capture Therapy of Liver Malignancies

    DEFF Research Database (Denmark)

    Schmitz, T.; Blaickner, M.; Ziegner, M.

    2011-01-01

    be suitable for measurements in mixed neutron and gamma fields. Materials and Methods Two experiments have been carried out in the thermal column of the TRIGA Mark II reactor at the University of Mainz. Alanine dosimeters have been irradiated in a phantom and in liver tissue. Results For the interpretation......, in combination with flux measurements and Monte Carlo calculations with FLUKA, suggest that it is possible to establish a system for monitoring the dose in a mixed neutron and gamma field for BNCT and other applications in radiotherapy....

  9. Neutron dose in and out of 18MV photon fields.

    Science.gov (United States)

    Ezzati, A O; Studenski, M T

    2017-04-01

    In radiation therapy, neutron contamination is an undesirable side effect of using high energy photons to treat patients. Neutron contamination requires adjustments to the shielding requirements of the linear accelerator vault and contributes to the risk of secondary malignancies in patients by delivering dose outside of the primary treatment field. Using MCNPX, an established Monte Carlo code, manufacturer blueprints, and the most up to date ICRP neutron dose conversion factors, the neutron spectra, neutron/photon dose ratio, and the neutron capture gamma ray dose were calculated at different depths and off axis distances in a tissue equivalent phantom. Results demonstrated that the neutron spectra and dose are dependent on field size, depth in the phantom, and off-axis distance. Simulations showed that because of the low neutron absorption cross section of the linear accelerator head materials, the contribution to overall patient dose from neutrons can be up to 1000 times the photon dose out of the treatment field and is also dependent on field size and depth. Beyond 45cm off-axis, the dependence of the neutron dose on field size is minimal. Neutron capture gamma ray dose is also field size dependent and is at a maximum at a depth of about 7cm. It is important to remember that when treating with high energy photons, the dose from contamination neutrons must be considered as it is much greater than the photon dose.

  10. Neutron spectrometry in mixed fields: superheated drop (bubble) detectors.

    Science.gov (United States)

    d'Errico, F; Matzke, M

    2003-01-01

    The BINS neutron threshold spectrometer permits the analysis of the main features of a neutron field for radiation protection purposes. The system offers a virtually complete photon discrimination and nested threshold responses to neutrons, which allow the use of very effective 'few-channel' unfolding procedures. To date, the practical operating energy range of a BINS is 0.1-10 MeV, over which a resolving power of 20-30% can be expected when the deconvolution is performed without explicit pre-information. Spectrum unfolding results in relatively high uncertainties on the differential fluence distributions, but due to negative correlations in adjacent energy groups the uncertainties on integral quantities such as dose equivalent are small and of the order of 5% to 10%, similar to the results of other active spectrometers. In comparison with most radiation detectors, the BINS is an extremely slow system due to the intrinsic duration of a bubble pulse and to the time associated with pulse analysis. For example, the maximum sustainable fluence rate of 1 MeV neutrons is about 10(4) cm(-2) s(-1), which is low for many neutron physics experiments. However, this rate corresponds to an ambient dose equivalent rate of about 1 mSv h(-1), making the active device adequate for radiation protection applications in the workplaces described in Section 1. There are ample margins for improvement of the spectrometer. In particular, in the low-energy region a thermal-epithermal neutron group may be added by using chlorine-bearing emulsions stabilised at suitable temperatures. In fact, the latest version of the system achieves this goal by using a single superheated emulsion of dichlorotetrafluoroethane (R-114) operated at temperatures up to 55 degrees C. This extends the range of the spectrometer and at the same time removes the undue enhancement of the UNFANA output in the low energy region. Above 10 MeV, the resolution can be improved by adding more thresholds, e.g. by starting from

  11. Influence of thermal and resonance neutron on fast neutron flux measurement by Pu-239 fission chamber

    CERN Document Server

    zeng, Lina; Song, Lingli; Zheng, Chun

    2014-01-01

    The Pu-239 fission chambers are widely used to measure fission spectrum neutron flux due to a flat response to fast neutrons. However, in the mean time the resonance and thermal neutrons can cause a significant influence on the measurement if they are moderated, which could be eliminated by using B and Cd covers. At a column enriched uranium fast neutron critical assembly, the fission reaction rates of Pu-239 are measured as 1.791*10-16,2.350*10-16 and 1.385*10-15 per second for 15mm thick B cover, 0.5mm thick Cd cover, and no cover respectively. While the fission reaction rate of Pu-239 is rapidly increased to 2.569*10-14 for a 20mm thick polythene covering fission chamber. The average Pu-239 fission cross-section of thermal and resonance neutrons is calculated to be 500b and 24.95b with the assumption of 1/v and 1/E spectra respectively, then thermal, resonance and fast neutron flux are achieved to be 2.30*106,2.24*106 and 1.04*108cm-2s-1.

  12. Magnetic field homogeneity for neutron EDM experiment

    Science.gov (United States)

    Anderson, Melissa

    2016-09-01

    The neutron electric dipole moment (nEDM) is an observable which, if non-zero, would violate time-reversal symmetry, and thereby charge-parity symmetry of nature. New sources of CP violation beyond those found in the standard model of particle physics are already tightly constrained by nEDM measurements. Our future nEDM experiment seeks to improve the precision on the nEDM by a factor of 30, using a new ultracold neutron (UCN) source that is being constructed at TRIUMF. Systematic errors in the nEDM experiment are driven by magnetic field inhomogeneity and instability. The goal field inhomogeneity averaged over the experimental measurement cell (order of 1 m) is 1 nT/m, at a total magnetic field of 1 microTesla. This equates to roughly 10-3 homogeneity. A particularly challenging aspect of the design problem is that nearby magnetic materials will also affect the magnetic inhomogeneity, and this must be taken into account in completing the design. This poster will present the design methodology and status of the main coil for the experiment where we use FEA software (COMSOL) to simulate and analyze the magnetic field. Natural Sciences and Engineering Research Council.

  13. Numerical research on the anisotropic transport of thermal neutron in heterogeneous porous media with micron X-ray computed tomography

    OpenAIRE

    Yong Wang; Wenzheng Yue; Mo Zhang

    2016-01-01

    The anisotropic transport of thermal neutron in heterogeneous porous media is of great research interests in many fields. In this paper, it is the first time that a new model based on micron X-ray computed tomography (CT) has been proposed to simultaneously consider both the separation of matrix and pore and the distribution of mineral components. We apply the Monte Carlo method to simulate thermal neutrons transporting through the model along different directions, and meanwhile detect those ...

  14. Study of the neutron field in the vicinity of an unshielded PET cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Mendez, R [Dpto. Fisica Teorica, Atomica y Optica, Universidad de Valladolid (Spain); Iniguez, M P [Dpto. Fisica Teorica, Atomica y Optica, Universidad de Valladolid (Spain); MartI-Climent, J M [Servicio de Medicina Nuclear, ClInica Universitaria de Navarra (Spain); Penuelas, I [Servicio de Medicina Nuclear, ClInica Universitaria de Navarra (Spain); Vega-Carrillo, H R [Dpto. Estudios Nucleares, IngenierIa Electrica, Matematicas, Universidad Autonoma de Zacatecas (Mexico); Barquero, R [Hospital Universitario RIo Hortega, Valladolid (Spain)

    2005-11-07

    The neutron field in the proximity of an unshielded PET cyclotron was investigated during {sup 18}F radioisotope production with an 18 MeV proton beam. Thermoluminescent detector (TLD) models TLD600 and TLD700 as well as Bonner moderating spheres were irradiated at different positions inside the vault room where the cyclotron is located to determine the thermal neutron flux, neutron spectrum and dose equivalent. Furthermore, from a combination of measurements and Monte Carlo simulations the neutron source intensity at the target was estimated. The resulting intensity is in good agreement with the IAEA recommendations. Neutron doses derived from the measured spectra were found to vary between 7 and 320 mSv per 1 {mu}A h of proton-integrated current. Finally, gamma doses were determined from TLD700 readings and amounted to around 10% of the neutron doses.

  15. Study of the neutron field in the vicinity of an unshielded PET cyclotron.

    Science.gov (United States)

    Méndez, R; Iñiguez, M P; Martí-Climent, J M; Peñuelas, I; Vega-Carrillo, H R; Barquero, R

    2005-11-01

    The neutron field in the proximity of an unshielded PET cyclotron was investigated during 18F radioisotope production with an 18 MeV proton beam. Thermoluminescent detector (TLD) models TLD600 and TLD700 as well as Bonner moderating spheres were irradiated at different positions inside the vault room where the cyclotron is located to determine the thermal neutron flux, neutron spectrum and dose equivalent. Furthermore, from a combination of measurements and Monte Carlo simulations the neutron source intensity at the target was estimated. The resulting intensity is in good agreement with the IAEA recommendations. Neutron doses derived from the measured spectra were found to vary between 7 and 320 mSv per 1 microA h of proton-integrated current. Finally, gamma doses were determined from TLD700 readings and amounted to around 10% of the neutron doses.

  16. Proposal of thermal neutron flux monitors based on vibrating wire

    CERN Document Server

    Arutunian, S G; Chung, M; Harutyunyan, G S; Lazareva, E G

    2015-01-01

    Two types of neutron monitors with fine spatial resolution are proposed based on vibrating wire. In the first type, neutrons interact with the vibrating wire, heat it, and lead to the change of natural frequency, which can be precisely measured. To increase the heat deposition during the neutron scattering, use of gadolinium layer which has the highest thermal neutron capture cross section among all elements is proposed. The second type of the monitor uses vibrating wire as a resonant target. Besides the measurement of beam profile according to the average signal, the differential signal synchronized with the wire oscillations defines the gradient of beam profile. Spatial resolution of the monitor is defined by the diameter of the wire.

  17. Spin diffusive modes and thermal transport in neutron star crusts

    CERN Document Server

    Sedrakian, Armen

    2015-01-01

    In this contribution we first review a method for obtaining the collective modes of pair-correlated neutron matter as found in a neutron star inner crust. We discuss two classes of modes corresponding to density and spin perturbations with energy spectra $\\omega = \\omega_0 + \\alpha q^2$, where $\\omega_0 = 2\\Delta$ is the threshold frequency and $\\Delta$ is the gap in the neutron fluid spectrum. For characteristic values of Landau parameters in neutron star crusts the exitonic density modes have $\\alpha 0$ and they exist above $\\omega_0$ which implies that these modes are damped. As an application of these findings we compute the thermal conductivity due to spin diffusive modes and show that it scales as $T^{1/2} \\exp(-2\\omega_0/T)$ in the case where their two-by-two scattering cross-section is weakly dependent on temperature.

  18. Computational characterization and experimental validation of the thermal neutron source for neutron capture therapy research at the University of Missouri

    Energy Technology Data Exchange (ETDEWEB)

    Broekman, J. D. [University of Missouri, Research Reactor Center, 1513 Research Park Drive, Columbia, MO 65211-3400 (United States); Nigg, D. W. [Idaho National Laboratory, PO Box 1625, Idaho Falls, ID 83415 (United States); Hawthorne, M. F. [University of Missouri, International Institute of Nano and Molecular Medicine, 1514 Research Park Dr., Columbia, MO 65211-3450 (United States)

    2013-07-01

    Parameter studies, design calculations and neutronic performance measurements have been completed for a new thermal neutron beamline constructed for neutron capture therapy cell and small-animal radiobiology studies at the University of Missouri Research Reactor. The beamline features the use of single-crystal silicon and bismuth sections for neutron filtering and for reduction of incident gamma radiation. The computational models used for the final beam design and performance evaluation are based on coupled discrete-ordinates and Monte Carlo techniques that permit detailed modeling of the neutron transmission properties of the filtering crystals with very few approximations. Validation protocols based on neutron activation spectrometry measurements and rigorous least-square adjustment techniques show that the beam produces a neutron spectrum that has the anticipated level of thermal neutron flux and a somewhat higher than expected, but radio-biologically insignificant, epithermal neutron flux component. (authors)

  19. Magnetic field devices for neutron spin transport and manipulation in precise neutron spin rotation measurements

    Science.gov (United States)

    Maldonado-Velázquez, M.; Barrón-Palos, L.; Crawford, C.; Snow, W. M.

    2017-05-01

    The neutron spin is a critical degree of freedom for many precision measurements using low-energy neutrons. Fundamental symmetries and interactions can be studied using polarized neutrons. Parity-violation (PV) in the hadronic weak interaction and the search for exotic forces that depend on the relative spin and velocity, are two questions of fundamental physics that can be studied via the neutron spin rotations that arise from the interaction of polarized cold neutrons and unpolarized matter. The Neutron Spin Rotation (NSR) collaboration developed a neutron polarimeter, capable of determining neutron spin rotations of the order of 10-7 rad per meter of traversed material. This paper describes two key components of the NSR apparatus, responsible for the transport and manipulation of the spin of the neutrons before and after the target region, which is surrounded by magnetic shielding and where residual magnetic fields need to be below 100 μG. These magnetic field devices, called input and output coils, provide the magnetic field for adiabatic transport of the neutron spin in the regions outside the magnetic shielding while producing a sharp nonadiabatic transition of the neutron spin when entering/exiting the low-magnetic-field region. In addition, the coils are self contained, forcing the return magnetic flux into a compact region of space to minimize fringe fields outside. The design of the input and output coils is based on the magnetic scalar potential method.

  20. Study of thermal neutron capture in /sup 32/S

    Energy Technology Data Exchange (ETDEWEB)

    GUO Taichang; SHI Zongren; ZENG Xiantang; LI Guohua; DING Dazhao

    1985-10-01

    The ..gamma..-ray spectrum of the /sup 32/S (n, ..gamma..) reaction at thermal neutron energy is measured by using a Ge(Li) detector. Among 86 ..gamma.. rays identified, 23 are recognized as primary ..gamma.. transitions. The excitation energies of 25 levels and the decay branching ratios are deduced. Three possible levels at 7505.0, 4473.1, and 2884.6 keV were not reported previously. The neutron separation energy of S is determined to be 8641.7 +- 0.6 keV. The thermal neutron capture cross section of /sup 32/S is determined to be 529 +- 26 mb by summing the transition intensities to the ground state of /sup 33/S and comparing with the well-known Au (n, ..gamma..) cross section. The partial capture cross sections of seven primary E1 transitions are calculated by the formula of the Lane-Lynn direct capture theory, and compared with measured values.

  1. Parameters measurement for the thermal neutron beam in the thermal column hole of Xi’an pulse reactor

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The distribution of the neutron spectra in the thermal column hole of Xi’an pulse reactor was measured with the time-of-flight method.Compared with the thermal Maxwellian theory neutron spectra,the thermal neutron spectra measured is a little softer,and the average neutron energy of the experimental spectra is about 0.042±0.01 eV.The thermal neutron fluence rate at the front end of thermal column hole,measured with gold foil activation techniques,is about 1.18×105 cm-2 s-1.The standard uncertainty of the measured thermal neutron fluence is about 3%.The spectra-averaged cross section of 197Au(n,γ) determined by the experimental thermal neutron spectra is(92.8±0.93) ×10-24 cm2.

  2. Shape Isomer in 236U Populated by Thermal Neutron Capture

    DEFF Research Database (Denmark)

    Andersen, Verner; Christensen, Carl Jørgen; Borggreen, J.

    1976-01-01

    The 116 ns shape isomer in 236U was populated by thermal neutron capture. Conversion electrons and X-rays were detected simultaneously in delayed coincidence with fission. The ratio of delayed to prompt fission was measured with the result, σIIf/σf = (1.0±0.2) × 10−5. A branching of the isomeric...

  3. A system of materials composition and geometry arrangement for fast neutron beam thermalization: An MCNP study

    Science.gov (United States)

    Uhlář, Radim; Alexa, Petr; Pištora, Jaromír

    2013-03-01

    Compact deuterium-tritium neutron generators emit fast neutrons (14.2 MeV) that have to be thermalized for neutron activation analysis experiments. To maximize thermal neutron flux and minimize epithermal and fast neutron fluxes across the output surface of the neutron generator facility, Monte Carlo calculations (MCNP5; Los Alamos National Laboratory) for different moderator types and widths and collimator and reflector designs have been performed. A thin lead layer close to the neutron generator as neutron multiplier followed by polyethylene moderator and surrounded by a massive lead and nickel collimator and reflector was obtained as the optimum setup.

  4. Characterization of neutron field in a NPP workplace.

    Science.gov (United States)

    Breznik, B; Pochat, J L; Muller, H; Asselineau, B; Pavlin, M

    2007-01-01

    At the Krsko Nuclear Power Plant (NPP), albedo dosimeters are used for personal neutron dosimetry. Spectrometric measurements allow determination of reference dosimetric values of realistic neutron fields to be used for calibration of albedo dosimeters. The Laboratory for Neutron Metrology and Dosimetry from the Institute for Radiological Protection and Nuclear Safety (IRSN) was in charge of characterising neutron fields in the plant at two representative points with high neutron and gamma dose rate. Calibration of the dosimeters in the workplace used to be performed only by a spherical survey meter. Based on the reference dosimetric values, the Plant Dosimetry Laboratory has verified the response of albedo dosimeters.

  5. ATLAS-TPX: a two-layer pixel detector setup for neutron detection and radiation field characterization

    Science.gov (United States)

    Bergmann, B.; Caicedo, I.; Leroy, C.; Pospisil, S.; Vykydal, Z.

    2016-10-01

    A two-layer pixel detector setup (ATLAS-TPX), designed for thermal and fast neutron detection and radiation field characterization is presented. It consists of two segmented silicon detectors (256 × 256 pixels, pixel pitch 55 μm, thicknesses 300 μm and 500 μm) facing each other. To enhance the neutron detection efficiency a set of converter layers is inserted in between these detectors. The pixelation and the two-layer design allow a discrimination of neutrons against γs by pattern recognition and against charged particles by using the coincidence and anticoincidence information. The neutron conversion and detection efficiencies are measured in a thermal neutron field and fast neutron fields with energies up to 600 MeV. A Geant4 simulation model is presented, which is validated against the measured detector responses. The reliability of the coincidence and anticoincidence technique is demonstrated and possible applications of the detector setup are briefly outlined.

  6. Stationary DIANE equipment Description and performance of the thermal neutron source

    Science.gov (United States)

    Cluzeau, S.; Le Tourneur, P.

    1994-05-01

    A new neutron radiography facility using a GENIE 46 generator is now operating at SODERN (France). In contrast to the first mobile DIANE system working at IABG (Germany), this new version uses a stationary thermal neutron source. With this second equipment the performance has been significantly improved. Thanks to computer simulations and experimental thermal neutron cartography, progress has been made on neutron moderation/thermalization (combination of lead and HD polyethylene), extraction geometry, neutron and photon collimation. The results in terms of gamma ray and thermal neutron contents in the beam are reported.

  7. Development of advanced radiation monitors for pulsed neutron fields

    CERN Document Server

    AUTHOR|(CDS)2081895

    The need of radiation detectors capable of efficiently measuring in pulsed neutron fields is attracting widespread interest since the 60s. The efforts of the scientific community substantially increased in the last decade due to the increasing number of applications in which this radiation field is encountered. This is a major issue especially at particle accelerator facilities, where pulsed neutron fields are present because of beam losses at targets, collimators and beam dumps, and where the correct assessment of the intensity of the neutron fields is fundamental for radiation protection monitoring. LUPIN is a neutron detector that combines an innovative acquisition electronics based on logarithmic amplification of the collected current signal and a special technique used to derive the total number of detected neutron interactions, which has been specifically conceived to work in pulsed neutron fields. Due to its special working principle, it is capable of overcoming the typical saturation issues encountere...

  8. The Magnificent Seven: Nearby Isolated Neutron Stars with strong Magnetic Fields

    CERN Document Server

    Haberl, F

    2005-01-01

    Although the true origin of the broad absorption lines in X-ray spectra of thermal isolated neutron stars is not clear yet, our current knowledge about the "magnificent seven" strongly suggests that they are highly magnetized ($10^{13} - 10^{14}$ G), slowly rotating cooling neutron stars. Further timing studies would be very useful to obtain more independent estimates of the magnetic field strength (as they currently only exist from RX J0720.4-3125).

  9. Fabrication and Characterization of a Conduction Cooled Thermal Neutron Filter

    Energy Technology Data Exchange (ETDEWEB)

    Heather Wampler; Adam Gerth; Heng Ban; Donna Post Guillen; Douglas Porter; Cynthia Papesch

    2010-06-01

    Installation of a conduction cooled thermal (low-energy) neutron filter in an existing domestic test reactor would provide the U.S. the capability to test new reactor fuels and materials for advanced fast (high-energy) reactor concepts. A composite consisting of Al3Hf-Al has been proposed for the neutron filter due to both the neutron filtering properties of hafnium and the conducting capabilities of aluminum. Knowledge of the thermal conductivity of the Al3Hf-Al composite is essential for the design of the filtering system. The present objectives are to identify a suitable fabrication technique and to measure the thermophysical properties of the Al3Hf intermetallic, which has not been done previous to this study. A centrifugal casting method was used to prepare samples of Al3Hf. X-ray diffraction and Rietveld analysis were conducted to determine the structural make-up of each of the samples. Thermophysical properties were measured as follows: specific heat by a differential scanning calorimeter (DSC), thermal diffusivity by a laser flash thermal diffusivity measuring system, thermal expansion by a dilatometer, and thermal conductivity was calculated based on the previous measurements. All measurements were acquired over a temperature range of 90°C - 375°C with some measurements outside these bounds. The average thermal conductivity of the intermetallic Al3Hf (~7 at.% Hf) was found to be ~ 41 W/m-K for the given temperature range. This information fills a knowledge gap in the thermophysical properties of the intermetallic Al3Hf with the specified percentage of hafnium. A model designed to predict composite properties was used to calculate a thermal conductivity of ~177 W/m-K for an Al3Hf-Al composite with 23 vol% Al3Hf. This calculation was based upon the average thermal conductivity of Al3Hf over the specified temperature range.

  10. Ortho- and para-hydrogen in neutron thermalization

    Energy Technology Data Exchange (ETDEWEB)

    Daemen, L. L.; Brun, T. O.

    1998-01-01

    The large difference in neutron scattering cross-section at low neutron energies between ortho- and para-hydrogen was recognized early on. In view of this difference (more than an order of magnitude), one might legitimately ask whether the ortho/para ratio has a significant effect on the neutron thermalization properties of a cold hydrogen moderator. Several experiments performed in the 60`s and early 70`s with a variety of source and (liquid hydrogen) moderator configurations attempted to investigate this. The results tend to show that the ortho/para ratio does indeed have an effect on the energy spectrum of the neutron beam produced. Unfortunately, the results are not always consistent with each other and much unknown territory remains to be explored. The problem has been approached from a computational standpoint, but these isolated efforts are far from having examined the ortho/para-hydrogen problem in neutron moderation in all its complexity. Because of space limitations, the authors cannot cover, even briefly, all the aspects of the ortho/para question here. This paper will summarize experiments meant to investigate the effect of the ortho/para ratio on the neutron energy spectrum produced by liquid hydrogen moderators.

  11. Thermal neutron detectors based on hexagonal boron nitride epilayers

    Science.gov (United States)

    Doan, T. C.; Marty, A.; Li, J.; Lin, J. Y.; Jiang, H. X.

    2016-09-01

    Solid-state neutron detectors with high performances are urgently sought after for the detection of fissile materials. Until now, direct-conversion neutron detectors based on semiconductors with a measureable efficiency have not been realized. We have successfully synthesized hexagonal boron nitride (h-BN) epilayers with varying thicknesses (0.3 μm - 50 μm) by metal organic chemical vapor deposition (MOCVD) on sapphire substrates. In this paper, we present the detailed characterization of thermal neutron detectors fabricated from h-BN epilayers with a thickness up to 5 m to obtain insights into the h-BN epilayer thickness dependence of the device performance. The results revealed that the charge collection efficiency is almost independent of the h-BN epilayer thickness. By minimizing h-BN material removal by dry etching, it was shown that detectors incorporating an isotopically 10B-enriched h-BN epilayer of 2.7 μm in thickness exhibited an overall detection efficiency for thermal neutrons of 4% and a charge collection efficiency as high as 83%. By doing away altogether with dry etching, we have successfully realized a simple vertical 43 μm thick h-10BN detector which delivers a detection efficiency of 51.4% for thermal neutrons, which is the highest reported efficiency for any semiconductor-based neutron detector The h-BN detectors possess all the advantages of semiconductor devices including low cost, high efficiency and sensitivity, wafer-scale processing, compact size, light weight, and ability to integrate with other functional devices.

  12. Spectrometer equipment for neutron spectra measurements in mixed neutron/photon fields

    CERN Document Server

    Chernov, V A; Trykov, L A

    2002-01-01

    The paper describes spectrometer equipment in the IPPE experimental laboratory for neutron spectra measurement in mixed (n,gamma) fields. The laboratory was founded in 1957 and it occupies a leading position in the field of nuclear facilities radiation spectrometry and benchmark experiments in Russia. Spectrometer equipment includes spectrometers based on the organic stilbene scintillator, hydrogen counter and Bonner balls. Basic fields of spectrometer application are mixed radiation neutron spectra measurement of radionuclide sources, of nuclear reactors and accelerators; study of neutron transfer through the material, including benchmark experiments and measurement of neutron spectra in the rooms of nuclear facilities.

  13. Neutron induced degradation in nitrided pyrogenic field oxide MOS capacitors

    CERN Document Server

    Vaidya, S J; Shaikh, A M; Chandorkar, A N

    2002-01-01

    Neutron induced oxide charge trapping and generation of interface states in MOS capacitors with pyrogenic and nitrided pyrogenic field oxides have been studied. In order to assess the damage due to neutrons alone, it is necessary to account for the damage produced by the accompanying gamma rays from neutron radiation. This is done by measuring the intensity of gamma radiation accompanying neutrons at different neutron fluences at the irradiation position. MOS capacitor structures were subjected to neutron radiation in a swimming pool type of reactor. Other samples from the same batch were then subjected to an equivalent dose of gamma radiation from a Co sup 6 sup 0 source. The difference in the damage observed was used to characterize the damage caused by neutrons. It is observed that neutrons, though uncharged, are capable of causing ionization damage. This damage is found to be significant when the radiation is performed under biased conditions. Nitridation in different ambients is found to improve the radi...

  14. Study of thermal neutron capture in /sup 23/Na

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Ming; Shi Zongren; Zeng Xiantang; Li Guohua; Ding Dazhao

    1987-11-01

    Energies and intensities of 117 gamma-rays produced by the capture of thermal neutron in /sup 23/Na are measured by using a single Ge(Li) detector and a pair spectrometer. 107 gamma-rays are placed in the decay scheme consisting of 35 levels. The neutron binding energy is found to be 6959.51 (21) keV. The parameters of /sup 24/Na energy level density are determined with the Back-Shift Fermi Gas Model. The /sup 23/Na(n, ..gamma..)/sup 24/Na reaction is mainly a statistical process from the resonance capture of 2.85 keV state.

  15. Study of thermal neutron capture in /sup 23/Na

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Ming; Shi Zongren; Zeng Xiantang; Li Guohua; Ding Dazhao

    1989-04-01

    Energies and intensities of 117 gamma-rays produced by the capture of thermal neutrons in /sup 23/Na are measured by using a single Ge(Li) detector and a pair spectrometer. 107 gamma-rays are placed in a decay scheme consisting of 35 levels. The neutron binding energy is found to be 6959.51 (21) keV. The parameters of /sup 24/Na energy-level density are determined with the Back-Shift Fermi Gas Model. The /sup 23/Na(/ital n/,..gamma..) /sup 24/Na reaction is mainly a statistical process from the resonance capture of the 2.85 keV state.

  16. New thermal neutron calibration channel at LNMRI/IRD

    Energy Technology Data Exchange (ETDEWEB)

    Astuto, A.; Lopes, R.T., E-mail: achillesbr@gmail.com [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil); Patrao, K.C.S.; Fonseca, E.S.; Pereira, W.W. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ/LNMRI), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes

    2015-07-01

    A new standard thermal neutron flux unit was designed in the National Ionizing Radiation Metrology Laboratory (LNMRI) for calibration of neutron detectors. Fluence is achieved by moderation of four {sup 241}Am-Be sources with 596 GBq each, in a facility built with graphite and paraffin blocks. The study was divided into two stages. First, simulations were performed using MCNPX code in different geometric arrangements, seeking the best performance in terms of fluence and their uncertainties. Last, the system was assembled based on the results obtained on the simulations. The simulation results indicate quasi-homogeneous fluence (less than 1%) in the central chamber. (author)

  17. Standard Test Method for Determining Thermal Neutron Reaction Rates and Thermal Neutron Fluence Rates by Radioactivation Techniques

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 The purpose of this test method is to define a general procedure for determining an unknown thermal-neutron fluence rate by neutron activation techniques. It is not practicable to describe completely a technique applicable to the large number of experimental situations that require the measurement of a thermal-neutron fluence rate. Therefore, this method is presented so that the user may adapt to his particular situation the fundamental procedures of the following techniques. 1.1.1 Radiometric counting technique using pure cobalt, pure gold, pure indium, cobalt-aluminum, alloy, gold-aluminum alloy, or indium-aluminum alloy. 1.1.2 Standard comparison technique using pure gold, or gold-aluminum alloy, and 1.1.3 Secondary standard comparison techniques using pure indium, indium-aluminum alloy, pure dysprosium, or dysprosium-aluminum alloy. 1.2 The techniques presented are limited to measurements at room temperatures. However, special problems when making thermal-neutron fluence rate measurements in high-...

  18. Handheld dual thermal neutron detector and gamma-ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Stowe, Ashley C.; Burger, Arnold; Bhattacharya, Pijush; Tupitsyn, Yevgeniy

    2017-05-02

    A combined thermal neutron detector and gamma-ray spectrometer system, including: a first detection medium including a lithium chalcopyrite crystal operable for detecting neutrons; a gamma ray shielding material disposed adjacent to the first detection medium; a second detection medium including one of a doped metal halide, an elpasolite, and a high Z semiconductor scintillator crystal operable for detecting gamma rays; a neutron shielding material disposed adjacent to the second detection medium; and a photodetector coupled to the second detection medium also operable for detecting the gamma rays; wherein the first detection medium and the second detection medium do not overlap in an orthogonal plane to a radiation flux. Optionally, the first detection medium includes a .sup.6LiInSe.sub.2 crystal. Optionally, the second detection medium includes a SrI.sub.2(Eu) scintillation crystal.

  19. Determining the thermal neutron absorption cross section of rocks

    Energy Technology Data Exchange (ETDEWEB)

    Kreft, A.; Dydejczyk, A.; Gyurcsak, J.

    1984-07-01

    A new simple rapid and cost effective method of determining the thermal neutron absorption cross section of rocks is proposed. It uses samples of about 2 kg and a measuring set-up consisting of paraffin block, Pu-Be neutron source emitting roughly 5 x 10/sup 5/ n/s, BF/sub 3/ proportional counter and conventional counting equipment. The method has been tested with a set of 49 artificial samples and 95% confidence intervals of about 0.27 m/sup -1/ have been estimated for 2 x 300 s counting times. Measurements carried out for several basalt samples have been compared with results obtained by a pulsed neutron technique.

  20. Magnetic Fields in neutron stars : A theoretical perspective

    NARCIS (Netherlands)

    Reisenegger, A.; Prieto, J.; Benguria, R.; Lai, D.; Araya, P.

    2005-01-01

    Abstract: We present our view of the main physical ingredients determining the evolution of neutron star magnetic fields. This includes the basic properties of neutron star matter, possible scenarios for the origin of the magnetic field, constraints and mechanisms for its evolution, and a discussion

  1. Thermal Neutron Point Source Imaging using a Rotating Modulation Collimator (RMC)

    Science.gov (United States)

    2010-03-01

    2.5 Neutron Attenuation Neutron attenuation is an important physical aspect that influences the design of the RMC components. The narrow- beam ...29 3.3 Mask Designs .......................................................................................................36 3.4 Neutron ...detection efficiency is very high for thermal and epithermal neutrons but begins to approach zero at 1 MeV and above. For this reason the detector is

  2. Efficiency and spatial resolution of the CASCADE thermal neutron detector

    Science.gov (United States)

    Köhli, M.; Allmendinger, F.; Häußler, W.; Schröder, T.; Klein, M.; Meven, M.; Schmidt, U.

    2016-08-01

    We report on the CASCADE project - a detection system, which has been designed for the purposes of neutron Spin Echo spectroscopy and which is continuously further developed and adapted to various applications. It features 2D spatially resolved detection of thermal neutrons at high rates. The CASCADE detector is composed of a stack of solid 10B coated Gas Electron Multiplier foils, which serve both as a neutron converter and as an amplifier for the primary ionization deposited in the standard counting gas environment. This multi-layer setup efficiently increases the detection efficiency and by extracting the signal of the charge traversing the stack the conversion layer can be identified allowing a precise determination of the time-of-flight. The spatial resolution is found by optical contrast determination to be σ =(1.39 ± 0.05) mm and by divergence corrected aperture measurements σ =(1.454 ± 0.007) mm , which is in agreement with the simulated detector model. Furthermore this enabled to investigate and describe the non-Gaussian resolution function. At the HEiDi diffractometer the absolute detection efficiency has been studied. At 0.6 Å for the 6 layer detector, which is currently part of the RESEDA spectrometer, an efficiency of 7.8% has been measured, which by means of Monte Carlo simulations translates to (21.0±1.5)% for thermal neutrons at 1.8 Å and (46.9±3.3)% at 5.4 Å.

  3. Thermal Neutron Tomography for Cultural Heritage at INR

    Science.gov (United States)

    Dinca, Marin; Mandescu, Dragos

    The neutron and gamma imaging facility placed at the tangential channel of the TRIGA-ACPR from INR was used for tomography investigations on a test object with good results and shortly followed its involvement for tomography investigations on prehistoric statues of clay from the Arges County Museum. This activity was performed in connection with a research contract with IAEA with title "The neutron and gamma imaging method combined with neutron-based analytical methods for cultural heritage research", in the frame of a current CRP, that helps curators to reveal the internal structure and composition of the objects. The detector system has been developed based on two interchangeable scintillators, one for thermal neutrons and the other one for gamma radiations, a mirror of float glass coated with aluminum and two interchangeable CCD cameras. Experiments of tomography imaging for two prehistoric statues of clay with CCD STARLIGHT XPRESS SXV-H9 camera with XD-4 type image intensifier are presented in this paper. The tomography reconstructions with Octopus software have shown the potential of good results even for 100 projections/1800. This was a good opportunity for the dissemination of the investigation methods based on neutrons for cultural heritage and beyond this area.

  4. Electrical conductivity of warm neutron star crust in magnetic fields

    CERN Document Server

    Harutyunyan, Arus

    2016-01-01

    We study the electrical conductivity of finite-temperature crust of a warm compact star which may be formed in the aftermath of a supernova explosion or a binary neutron star merger as well as when a cold neutron star is heated by accretion of material from a companion. We focus on the temperature-density regime where plasma is in the liquid state and, therefore, the conductivity is dominated by the electron scattering off correlated nuclei. The dynamical screening of this interaction is implemented in terms of polarization tensor computed in the hard-thermal-loop effective field theory of QED plasma. The correlations of the background ionic component are accounted for via a structure factor derived from Monte-Carlo simulations of one-component-plasma. With this input we solve the Boltzmann kinetic equation in relaxation time approximation taking into account the anisotropy of transport due to the magnetic field. The electrical conductivity tensor is studied numerically as a function of temperature and densit...

  5. The review of the application of neutron radiography to thermal hydraulic research

    CERN Document Server

    Mishima, K; Saitô, Y; Nakamura, H; Matsubayashi, M

    1999-01-01

    This paper is concerned with the establishment of thermal neutron radiography as a high accuracy measurement method. This paper reviews the present status on the development of high-frame-rate neutron radiography with a steady thermal neutron beam and its application to multiphase flow research performed at the Research Reactor Institute of Kyoto University in collaboration with the Japan Atomic Energy Research Institute.

  6. Thermal-neutron capture gamma rays from natural calcium

    NARCIS (Netherlands)

    Gruppelaar, H.; Spilling, P.

    1967-01-01

    Gamma rays from thermal-neutron capture in natural Ca and enriched 40Ca were investigated with a 5 cm3 Ge(Li) detector. Many low-energy γ-lines have been found. More than 90% of the γ-rays result from capture in 40Ca and about 5% from capture in 44Ca. From the data a decay scheme of 41Ca and a parti

  7. Response of a lithium gadolinium borate scintillator in monoenergetic neutron fields.

    Science.gov (United States)

    Williams, A M; Beeley, P A; Spyrou, N M

    2004-01-01

    Accurate estimation of neutron dose requires knowledge of the neutron energy distribution in the working environment. Existing neutron spectrometry systems, Bonner spheres for example, are large and bulky, and require long data acquisition times. A portable system that could indicate the approximate neutron energy spectrum in a short time would be extremely useful in radiation protection. A composite scintillator, consisting of lithium gadolinium borate crystals in a plastic scintillator matrix, produced by Photogenics is being tested for this purpose. A prototype device based on this scintillator and digital pulse processing electronics has been calibrated using quasi-monoenergetic neutron fields at the low-scatter facility of the UK National Physical Laboratory (NPL). Energies selected were 144, 250, 565, 1400, 2500 and 5000 keV, with correction for scattered neutrons being made using the shadow cone technique. Measurements were also made in the NPL thermal neutron field. Pulse distributions collected with the digitiser in capture-gated mode are presented, and detection efficiency and energy resolution derived. For comparison, neutron spectra were also collected using the commercially available Microspec N-Probe from Bubble Technology Industries, which consists of an NE213 scintillator and a 3He proportional counter.

  8. Neutron Tomography Using Mobile Neutron Generators for Assessment of Void Distributions in Thermal Hydraulic Test Loops

    Science.gov (United States)

    Andersson, P.; Bjelkenstedt, T.; Sundén, E. Andersson; Sjöstrand, H.; Jacobsson-Svärd, S.

    Detailed knowledge of the lateral distribution of steam (void) and water in a nuclear fuel assembly is of great value for nuclear reactor operators and fuel manufacturers, with consequences for both reactor safety and economy of operation. Therefore, nuclear relevant two-phase flows are being studied at dedicated thermal-hydraulic test loop, using two-phase flow systems ranging from simplified geometries such as heated circular pipes to full scale mock-ups of nuclear fuel assemblies. Neutron tomography (NT) has been suggested for assessment of the lateral distribution of steam and water in such test loops, motivated by a good ability of neutrons to penetrate the metallic structures of metal pipes and nuclear fuel rod mock-ups, as compared to e.g. conventional X-rays, while the liquid water simultaneously gives comparatively good contrast. However, these stationary test loops require the measurement setup to be mobile, which is often not the case for NT setups. Here, it is acknowledged that fast neutrons of 14 MeV from mobile neutron generators constitute a viable option for a mobile NT system. We present details of the development of neutron tomography for this purpose at the division of Applied Nuclear Physics at Uppsala University. Our concept contains a portable neutron generator, exploiting the fusion reaction of deuterium and tritium, and a detector with plastic scintillator elements designed to achieveadequate spatial and energy resolution, all mounted in a light-weight frame without collimators or bulky moderation to allow for a mobile instrument that can be moved about the stationary thermal hydraulic test sections. The detector system stores event-to-event pulse-height information to allow for discrimination based on the energy deposition in the scintillator elements.

  9. Neutron radiography as a non-destructive method for diagnosing neutron converters for advanced thermal neutron detectors

    Science.gov (United States)

    Muraro, A.; Albani, G.; Perelli Cippo, E.; Croci, G.; Angella, G.; Birch, J.; Cazzaniga, C.; Caniello, R.; Dell'Era, F.; Ghezzi, F.; Grosso, G.; Hall-Wilton, R.; Höglund, C.; Hultman, L.; Schimdt, S.; Robinson, L.; Rebai, M.; Salvato, G.; Tresoldi, D.; Vasi, C.; Tardocchi, M.

    2016-03-01

    Due to the well-known problem of 3He shortage, a series of different thermal neutron detectors alternative to helium tubes are being developed, with the goal to find valid candidates for detection systems for the future spallation neutron sources such as the European Spallation Source (ESS). A possible 3He-free detector candidate is a charged particle detector equipped with a three dimensional neutron converter cathode (3D-C). The 3D-C currently under development is composed by a series of alumina (Al2O3) lamellas coated by 1 μ m of 10B enriched boron carbide (B4C). In order to obtain a good characterization in terms of detector efficiency and uniformity it is crucial to know the thickness, the uniformity and the atomic composition of the B4C neutron converter coating. In this work a non-destructive technique for the characterization of the lamellas that will compose the 3D-C was performed using neutron radiography. The results of these measurements show that the lamellas that will be used have coating uniformity suitable for detector applications. This technique (compared with SEM, EDX, ERDA, XPS) has the advantage of being global (i.e. non point-like) and non-destructive, thus it is suitable as a check method for mass production of the 3D-C elements.

  10. Transparent lithiated polymer films for thermal neutron detection

    Energy Technology Data Exchange (ETDEWEB)

    Mabe, Andrew N., E-mail: andrew.n.mabe@gmail.com [Department of Chemistry, University of Tennessee, Knoxville, TN 37996 (United States); Auxier, John D. [Department of Chemistry, University of Tennessee, Knoxville, TN 37996 (United States); Urffer, Matthew J. [Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Penumadu, Dayakar [Department of Civil and Environmental Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Schweitzer, George K. [Department of Chemistry, University of Tennessee, Knoxville, TN 37996 (United States); Miller, Laurence F. [Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States)

    2013-09-11

    Novel water-soluble {sup 6}Li loaded copolymer scintillation films have been designed and fabricated to detect thermal neutrons. Styrene and maleic anhydride were copolymerized to form an alternating copolymer, then the anhydride functionality was hydrolyzed using {sup 6}Li hydroxide. The resulting poly(styrene-co-lithium maleate) was mixed with salicylic acid as a fluor and cast as a thin film from water. The maximum {sup 6}Li loading obtained that resulted in a transparent film was 4.36% by mass ({sup 6}Li to polymer). The optimum fluorescence output was obtained for 11.7% salicylic acid by mass, presumably in the form of lithium salicylate, resulting in an optimum film containing 3.85% by mass of {sup 6}Li. A facile and robust synthesis method, film fabrication protocol, photoluminescence results, and scintillation responses are reported herein. -- Highlights: • A transparent polymer scintillator containing 3.85 wt% {sup 6}Li has been synthesized. • This class of polymeric thermal neutron scintillation detector is water-soluble. • Salicylic acid, presumably in the form of lithium salicylate, is used as a fluor. • The material emits 373 photons/α ({sup 241}Am) and an average of 139 photons/β ({sup 36}Cl). • The material emits 360 photons per thermal neutron capture event.

  11. Quiescent thermal emission from neutron stars in LMXBs

    CERN Document Server

    Turlione, Anabela; Pons, José A

    2013-01-01

    The quiescent thermal emission from neutron stars in low mass X-ray binaries after active periods of intense activity in x-rays (outbursts) has been monitored. The theoretical modeling of the thermal relaxation of the neutron star crust may be used to establish constraints on the crust and envelope composition and transport properties, depending on the astrophysical scenarios assumed. We perform numerical simulations of the neutron star crust thermal evolution and compare them with inferred surface temperatures for five sources: MXB 1659-29, KS 1731-260, EXO 0748-676, XTE J1701-462 and IGR J17480-2446. We also present stationary envelope models to be used as a boundary condition for the crustal cooling models. We obtain a relation between the mass accretion rate and the temperature reached at the crust-envelope interface at the end of the active phase that accounts for early observations and reduces the number of free parameters of the problem. With this relation we are also able to set constraints to the env...

  12. distributions for the thermal neutron induced fission of 234U

    Directory of Open Access Journals (Sweden)

    Al-Adili A.

    2016-01-01

    In addition, the analysis of thermal neutron induced fission of 234U(n,f will be discussed. Currently analysis of data is ongoing, originally taken at the ILL reactor. The experiment is of particular interest since no measurement exist of the mass and energy distributions for this system at thermal energies. One main problem encountered during analysis was the huge background of 235U(nth,f. Despite the negligible isotopic traces in the sample, the cross section difference is enormous. Solution to this parasitic background will be highlighted.

  13. Rotating proto-neutron stars under strong magnetic fields

    CERN Document Server

    Franzon, B; Schramm, S

    2016-01-01

    In this work, we study the effects of magnetic fields and rotation on the structure and composition of proto-neutron stars (PNSs). A hadronic chiral SU(3) model is applied to cold neutron stars (NS) and proto-neutron stars with trapped neutrinos and at fixed entropy per baryon. We obtain general relativistic solutions for neutron and proto-neutron stars endowed with a poloidal magnetic field by solving Einstein-Maxwell field equations in a self-consistent way. As the neutrino chemical potential decreases in value over time, this alters the chemical equilibrium and the composition inside the star, leading to a change in the structure and in the particle population of these objects. We find that the magnetic field deforms the star and significantly alters the number of trapped neutrinos in the stellar interior, together with strangeness content and temperature in each evolution stage.

  14. Thermalization Using Quantum Field Dynamics?

    CERN Document Server

    Salle, M; Vink, Jeroen C

    2001-01-01

    We describe a Hartree ensemble method to approximately solve the Heisenberg equations for the \\phi^4 model in 1+1 dimensions. We compute the energies and number densities of the quantum particles described by the \\phi field and find that the particles initially thermalize with a Bose-Einstein distribution for the particle density. Gradually, however, the distribution changes towards classical equipartition. Using suitable initial conditions quantum thermalization is achieved much faster than the onset of this undesirable equipartition. We also show how the numerical efficiency of our method can be significantly improved.

  15. Ionization signals from diamond detectors in fast-neutron fields

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, C. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); CIVIDEC Instrumentation, Wien (Austria); Frais-Koelbl, H. [University of Applied Sciences, Wiener Neustadt (Austria); Griesmayer, E.; Kavrigin, P. [CIVIDEC Instrumentation, Wien (Austria); Vienna University of Technology, Wien (Austria)

    2016-09-15

    In this paper we introduce a novel analysis technique for measurements with single-crystal chemical vapor deposition (sCVD) diamond detectors in fast-neutron fields. This method exploits the unique electronic property of sCVD diamond sensors that the signal shape of the detector current is directly proportional to the initial ionization profile. In fast-neutron fields the diamond sensor acts simultaneously as target and sensor. The interaction of neutrons with the stable isotopes {sup 12}C and {sup 13}C is of interest for fast-neutron diagnostics. The measured signal shapes of detector current pulses are used to identify individual types of interactions in the diamond with the goal to select neutron-induced reactions in the diamond and to suppress neutron-induced background reactions as well as γ-background. The method is verified with experimental data from a measurement in a 14.3 MeV neutron beam at JRC-IRMM, Geel/Belgium, where the {sup 13}C(n, α){sup 10}Be reaction was successfully extracted from the dominating background of recoil protons and γ-rays and the energy resolution of the {sup 12}C(n, α){sup 9}Be reaction was substantially improved. The presented analysis technique is especially relevant for diagnostics in harsh radiation environments, like fission and fusion reactors. It allows to extract the neutron spectrum from the background, and is particularly applicable to neutron flux monitoring and neutron spectroscopy. (orig.)

  16. Ionization signals from diamond detectors in fast-neutron fields

    Science.gov (United States)

    Weiss, C.; Frais-Kölbl, H.; Griesmayer, E.; Kavrigin, P.

    2016-09-01

    In this paper we introduce a novel analysis technique for measurements with single-crystal chemical vapor deposition (sCVD) diamond detectors in fast-neutron fields. This method exploits the unique electronic property of sCVD diamond sensors that the signal shape of the detector current is directly proportional to the initial ionization profile. In fast-neutron fields the diamond sensor acts simultaneously as target and sensor. The interaction of neutrons with the stable isotopes 12 C and 13 C is of interest for fast-neutron diagnostics. The measured signal shapes of detector current pulses are used to identify individual types of interactions in the diamond with the goal to select neutron-induced reactions in the diamond and to suppress neutron-induced background reactions as well as γ-background. The method is verified with experimental data from a measurement in a 14.3 MeV neutron beam at JRC-IRMM, Geel/Belgium, where the 13C(n, α)10Be reaction was successfully extracted from the dominating background of recoil protons and γ-rays and the energy resolution of the 12C(n, α)9Be reaction was substantially improved. The presented analysis technique is especially relevant for diagnostics in harsh radiation environments, like fission and fusion reactors. It allows to extract the neutron spectrum from the background, and is particularly applicable to neutron flux monitoring and neutron spectroscopy.

  17. Energy of Gravitational Field of Static Spherically Symmetric Neutron Stars

    Institute of Scientific and Technical Information of China (English)

    WENDe-Hua; CHENWei; WANGXian-Ju; AIBao-Quan; LIUGuo-Tao; LIULiang-Gang

    2003-01-01

    By using the Einstein-Tolman expression of the energy-momentum pseudo-tensor, the energy density of the gravitational field of the static spherically symmetric neutron stars is calculated in the Cartesian coordinate system.It is exciting that the energy density of gravitational field is positive and rational The xmmerical results of the energy density of gravitational field of neutron stars are calculated. For neutron stars with M=2M, the ratio of the energy density of gravitational field to the energy density of pure matters would be up to 0.54 at the surface.

  18. Neutron Tomography Using Mobile Neutron Generators for Assessment of Void Distributions in Thermal Hydraulic Test Loops

    OpenAIRE

    Andersson, Peter; Bjelkenstedt, Tom; Andersson Sundén, Erik; Sjöstrand, Henrik; Jacobsson, Staffan

    2015-01-01

    Detailed knowledge of the lateral distribution of steam (void) and water in a nuclear fuel assembly is of great value for nuclear reactor operators and fuel manufacturers, with consequences for both reactor safety and economy of operation. Therefore, nuclear relevant two-phase flows are being studied at dedicated thermal-hydraulic test loop, using twophase flow systems ranging from simplified geometries such as heated circular pipes to full scale mock-ups of nuclear fuel assemblies. Neutron t...

  19. The thermal neutron scattering cross section of {sup 86}Kr

    Energy Technology Data Exchange (ETDEWEB)

    Terburg, B.P.

    1992-05-01

    The availability of 27 1 STP krypton-86 gas, an isotope with unknown thermal neutron scattering cross section, was an excellent occasion to determine the (bound atom) scattering cross section and its coherent part by application of the neutron transmission method and neutron interferometry. The transmission method was applied in a diffractometer, a Larmor spectrometer and a TOF-spectrometer. In addition to {sup 86}Kr also natural krypton ({sup n}Kr) was used for sample in the diffractometer. The diffractometer measurements result in bound atom scattering cross sections {sigma}{sub s}=8.92(46) b for {sup 86}Kr and {sigma}{sub s}=7.08(95) b for {sup n}Kr. The Larmor transmission measurements lead to a final result {sigma}{sub s}=8.44(9) b for {sup 86}Kr. In the TOF-spectrometer the wavelength-dependent total cross section of water was determined. Coherent neutron scattering lengths were determined using the neutron interferometry method with a skew symmetric neutron interferometer. Scans with {sup 86}Kr and {sup n}Kr led to b{sub c}=8.07(26) fm for {sup 86}Kr and 7.72(33) fm for {sup n}Kr, corresponding to coherent scattering cross sections {sigma}{sub c}=8.18(53) b and 7.49(64) b respectively. Due to the large errors in the bound atom scattering cross section and coherent scattering cross section of {sup 86}Kr and {sup n}Kr, the incoherent cross section of both gases, {sigma}{sub i} = 0 within its inaccuracy, {sigma}{sub i}=0.26(54) b for {sup 86}Kr and {sigma}{sub i}=0.41(1.15) b for {sup n}Kr. (orig.).

  20. {sup 6}Li foil scintillation sandwich thermal neutron detector

    Energy Technology Data Exchange (ETDEWEB)

    Ianakiev, K.D., E-mail: ianakiev@lanl.gov [Los Alamos National Laboratory, MS E540, Los Alamos, NM 87545 (United States); Swinhoe, M.T.; Favalli, A.; Chung, K.; MacArthur, D.W. [Los Alamos National Laboratory, MS E540, Los Alamos, NM 87545 (United States)

    2011-10-01

    Increasing needs for neutron detection and limited supply of {sup 3}He have led to the need for replacement neutron detection technology. This paper presents the design and initial results for a neutron detector ({sup 6}Li foil scintillator sandwich) that uses lithium metal foil to detect thermal neutrons. The reaction products, primarily triton, deposit most of their energy in thin scintillator films and create light pulses. Gamma rays can deposit only a small amount of energy in the thin films and so produce only very small light pulses. Lithium is preferable to boron in this application because triton escapes from lithium more easily than does the alpha particle from boron, allowing the use of thicker films and hence greater efficiency. In addition, triton has a higher light output in the scintillator than the boron alpha particle. Lithium metal is preferable to a lithium compound, such as lithium fluoride, because the number of tritons that escape from the metal is greater for the same amount of lithium. Monte Carlo simulations show that good efficiency values can be achieved with reasonably sized detectors, values that are greater than that of comparable {sup 3}He systems for portal monitors. In addition, simulations of a neutron coincidence counting concept show high counting efficiency and short die-away time (16 {mu}s), which imply better performance than that of the high-level neutron coincidence counter (HLNCC)-II. Initial experimental measurements on a prototype detector using alpha particles (having similar light output to the expected tritons) show good light collection and transport properties.

  1. Measurement of accelerator neutron radiation field spectrum by Extended Range Neutron Multisphere Spectrometers and unfolding program

    CERN Document Server

    Li, Guanjia; Ma, Zhongjian; Guo, Siming; Yan, Mingyang; Shi, Haoyu; Xu, Chao

    2015-01-01

    This paper described a measurement of accelerator neutron radiation field at a transport beam line of Beijing-TBF. The experiment place was be selected around a Faraday Cup with a graphite target impacted by electron beam at 2.5GeV. First of all, we simulated the neutron radiation experiment by FLUKA. Secondly, we chose six appropriate ERNMS according to their neutron fluence response function to measure the neutron count rate. Then the U_M_G package program was be utilized to unfolding experiment data. Finally, we drew a comparison between the unfolding with the simulation spectrum and made an analysis about the result.

  2. SNM detection by means of thermal neutron interrogation and a liquid scintillation detector

    Science.gov (United States)

    Ocherashvili, A.; Roesgen, E.; Beck, A.; Caspi, E. N.; Mosconi, M.; Crochemore, J.-M.; Pedersen, B.

    2012-03-01

    The feasibility of using a pulsed neutron generator in a graphite assembly together with a single liquid scintillation detector for the detection of special nuclear materials is investigated. Thermal source neutrons induce fission in fissile material present in the sample. By means of pulse shape discrimination the detector signals from fast fission neutrons are easily identified among the signals from gamma rays and the interrogating thermal neutrons. The method has potential in applications for detection of special nuclear materials in shielded containers.

  3. Rotational and magnetic field instabilities in neutron stars

    Energy Technology Data Exchange (ETDEWEB)

    Kokkotas, Kostas D. [Theoretical Astrophysics, IAAT, Eberhard Karls University of Tübingen, Tübingen 72076 (Germany)

    2014-01-14

    In this short review we present recent results on the dynamics of neutron stars and their magnetic fields. We discuss the progress that has been made, during the last 5 years, in understanding the rotational instabilities with emphasis to the one due to the f-mode, the possibility of using gravitational wave detection in constraining the parameters of neutron stars and revealing the equation of state as well as the detectability of gravitational waves produced during the unstable phase of a neutron star’s life. In addition we discuss the dynamics of extremely strong magnetic fields observed in a class of neutron stars (magnetars). Magnetic fields of that strength are responsible for highly energetic phenomena (giant flares) and we demonstrate that the analysis of the emitted electromagnetic radiation can lead in constraining the parameters of neutron stars. Furthermore, we present our results from the study of such violent phenomena in association with the emission of gravitational radiation.

  4. LiCaAlF6 scintillators in neutron and gamma radiation fields

    Science.gov (United States)

    Viererbl, L.; Klupák, V.; Vinš, M.; Koleška, M.; Šoltés, J.; Yoshikawa, A.; Nikl, M.

    2016-09-01

    Intentionally doped LiCaAlF6 (LiCAF) single crystals are prospective scintillators, especially for thermal neutron detection through the 6Li(n,t)4He nuclear reaction. Four different LiCAF scintillator samples were tested in various neutron and gamma fields. Two of the tested samples were LiCAF:Eu and LiCAF:Eu,Na single crystals, and another two samples were made of LiCAF:Eu micro crystals dispersed in transparent rubber, with different rubber dimensions. All LiCAF samples contain lithium enriched to6Li. A plutonium-beryllium source was used as a neutron source. The neutron spectrum was modified by moderator and filter to get different ratios between thermal, epithermal and fast neutron fluence rates. The MCNP code was used for calculations of the fluence rates for different configurations. Radionuclides 137Cs and 60Co were applied as gamma radiation sources. The light signal from the scintillator was evaluated with a photomultiplier and a multichannel analyzer. The purpose of this work was to study the characteristics of LiCAF scintillators, especially the ability to discriminate signals from neutron and gamma radiation, which is the basic scintillator condition for neutron detection in mixed neutron-gamma radiation fields. Generally, the discrimination can be done by the pulse height and/or the pulse shape of the evaluated signals. Both methods can be used for a LiCAF scintillator. However, only the pulse height discrimination method is discussed in this paper. The possibility of fast neutron detection with LiCAF scintillators was also tested.

  5. Evaluation of room-scattered neutrons at the JNC Tokai neutron reference field

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Tadayoshi; Tsujimura, Norio [Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan). Tokai Works; Oyanagi, Katsumi [Japan Radiation Engineering Co., Ltd., Hitachi, Ibaraki (Japan)

    2002-09-01

    Neutron reference fields for calibrating neutron-measuring devices in JNC Tokai Works are produced by using radionuclide neutron sources, {sup 241}Am-Be and {sup 252}Cf sources. The reference field for calibration includes scattered neutrons from the material surrounding sources, wall, floor and ceiling of the irradiation room. It is, therefore, necessary to evaluate the scattered neutrons contribution and their energy spectra at reference points. Spectral measurements were performed with a set of Bonner multi-sphere spectrometers and the reference fields were characterized in terms of spectral composition and the fractions of room-scattered neutrons. In addition, two techniques stated in ISO 10647, the shadow-cone method and the polynomial fit method, for correcting the contributions from the room-scattered neutrons to the readings of neutron survey instruments were compared. It was found that the two methods gave an equivalent result within a deviation of 3.3% at a source-to-detector distance from 50cm to 500cm. (author)

  6. Unifying the observational diversity of isolated neutron stars via magneto-thermal evolution models

    CERN Document Server

    Viganò, Daniele; Pons, Jose A; Perna, Rosalba; Aguilera, Deborah N; Miralles, Juan A

    2013-01-01

    Observations of magnetars and some of the high magnetic field pulsars have shown that their thermal luminosity is systematically higher than that of classical radio-pulsars, thus confirming the idea that magnetic fields are involved in their X-ray emission. Here we present the results of 2D simulations of the fully-coupled evolution of temperature and magnetic field in neutron stars, including the state-of-the-art kinetic coefficients and, for the first time, the important effect of the Hall term. After gathering and thoroughly re-analysing in a consistent way all the best available data on isolated, thermally emitting neutron stars, we compare our theoretical models to a data sample of 40 sources. We find that our evolutionary models can explain the phenomenological diversity of magnetars, high-B radio-pulsars, and isolated nearby neutron stars by only varying their initial magnetic field, mass and envelope composition. Nearly all sources appear to follow the expectations of the standard theoretical models. ...

  7. Study on neutron radiation field of carbon ions therapy

    CERN Document Server

    Xu, Jun-Kui; Li, Wu-Yuan; Yan, Wei-Wei; Chen, Xi-Meng; Mao, Wang; Pang, Cheng-Guo

    2015-01-01

    Carbon ions offer significant advantages for deep-seated local tumors therapy due to their physical and biological properties. Secondary particles, especially neutrons caused by heavy ion reactions should be carefully considered in treatment process and radiation protection. For radiation protection purposes, the FLUKA Code was used in order to evaluate the radiation field at deep tumor therapy room of HIRFL in this paper. The neutron energy spectra, neutron dose and energy deposition of carbon ion and neutron in tissue-like media was studied for bombardment of solid water target by 430MeV/u C ions. It is found that the calculated neutron dose have a good agreement with the experimental date, and the secondary neutron dose may not exceed one in a thousand of the carbon ions dose at Bragg peak area in tissue-like media.

  8. Flexible neutron shielding composite material of EPDM rubber with boron trioxide: Mechanical, thermal investigations and neutron shielding tests

    Science.gov (United States)

    Özdemir, T.; Güngör, A.; Reyhancan, İ. A.

    2017-02-01

    In this study, EPDM and boron trioxide composite was produced and mechanical, thermal and neutron shielding tests were performed. EPDM rubber (Ethylene Propylene Diene Monomer) having a considerably high hydrogen content is an effective neutron shielding material. On the other hand, the materials containing boron components have effective thermal neutron absorption crossection. The composite of EPDM and boron trioxide would be an effective solution for both respects of flexibility and effectiveness for developing a neutron shielding material. Flexible nature of EPDM would be a great asset for the shielding purpose in case of intervention action to a radiation accident. The theoretical calculations and experimental neutron absorption tests have shown that the results were in parallel and an effective neutron shielding has been achieved with the use of the developed composite material.

  9. New thermal neutron calibration channel at LNMRI/IRD

    Science.gov (United States)

    Astuto, A.; Patrão, K. C. S.; Fonseca, E. S.; Pereira, W. W.; Lopes, R. T.

    2016-07-01

    A new standard thermal neutron flux unit was designed in the National Ionizing Radiation Metrology Laboratory (LNMRI) for calibration of neutron detectors. Fluence is achieved by moderation of four 241Am-Be sources with 0.6 TBq each, in a facility built with graphite and paraffin blocks. The study was divided into two stages. First, simulations were performed using MCNPX code in different geometric arrangements, seeking the best performance in terms of fluence and their uncertainties. Last, the system was assembled based on the results obtained on the simulations. The simulation results indicate quasi-homogeneous fluence in the central chamber and H*(10) at 50 cm from the front face with the polyethylene filter.

  10. Experimental evaluation of scattered thermal neutrons from various jig materials for use in fixing detectors for the calibration

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Shigeru; Yoshizawa, Michio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Nemoto, Hisashi; Kurosawa, Koji [Institute of Radiation Measurement, Tokai, Ibaraki (Japan)

    2000-05-01

    Some jigs to fix detectors are used when radiation measuring instruments are calibrated or reference fluence rates are measured in thermal neutron irradiation fields. In this case, scattered thermal neutrons from the jigs, in particular, which contain hydrogenous materials, may affect the results of the calibration and measurements. In this study, scattered thermal neutrons were measured and calculated to clarify the characteristics of the thermal neutron scattered from various materials which are frequently used for the jigs. A spherical BF{sub 3}-counter of 2-inches in diameter was used in the experiment. Ratios of the fluence of scattered neutrons to primaries (hereinafter, scattering ratio) were evaluated as a function of thickness and size of the materials, as well as the distance from the surface of the materials. The scattering ratios of the jigs that were actually-used in the calibration were also measured in order to select appropriate materials and thickness for the jigs. It was found that the scattering ratios were saturated with increase of thickness and size of the materials. The higher values were observed in the case of PMMA (polymethylmethacrylates) and paraffin since these materials contain more number of hydrogen atoms than the others. The saturated value was obtained 130% for PMMA and paraffin with the thickness of more than 5 cm and the size of 40 cm x 40 cm. The results for the actually-used jigs show that the thinner plate of styrofoam and aluminum reduces the scattering ratio to the value of less than 1%. The obtained data will be useful to improve the accuracy of the calibration of thermal neutron detectors and the measurement of reference fluence rates in thermal neutron irradiation fields. (author)

  11. Thermal Performance and Operation Limit of Heat Pipe Containing Neutron Absorber

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Mo; Jeong, Yeong Shin; Kim, In Guk; Bang, In Choel [UNIST, Ulsan (Korea, Republic of)

    2015-05-15

    Recently, passive safety systems are under development to ensure the core cooling in accidents involving impossible depressurization such as station blackout (SBO). Hydraulic control rod drive mechanisms, passive auxiliary feedwater system (PAFS), Passive autocatalystic recombiner (PAR), and so on are types of passive safety systems to enhance the safety of nuclear power plants. Heat pipe is used in various engineering fields due to its advantages in terms of easy fabrication, high heat transfer rate, and passive heat transfer. Also, the various concepts associated with safety system and heat transfer using the heat pipe were developed in nuclear engineering field.. Thus, our group suggested the hybrid control rod which combines the functions of existing control rod and heat pipe. If there is significant temperature difference between active core and condenser, the hybrid control rod can shutdown the nuclear fission reaction and remove the decay heat from the core to ultimate heat sink. The unique characteristic of the hybrid control rod is the presence of neutron absorber inside the heat pipe. Many previous researchers studied the effect of parameters on the thermal performance of heat pipe. However, the effect of neutron absorber on the thermal performance of heat pipe has not been investigated. Thus, the annular heat pipe which contains B{sub 4}C pellet in the normal heat pipe was prepared and the thermal performance of the annular heat pipe was studied in this study. Hybrid control rod concept was developed as a passive safety system of nuclear power plant to ensure the safety of the reactor at accident condition. The hybrid control rod must contain the neutron absorber for the function as a control rod. So, the effect of neutron absorber on the thermal performance of heat pipe was experimentally investigated in this study. Temperature distributions at evaporator section of annular heat pipe were lower than normal heat pipe due to the larger volume occupied by

  12. Differences in TLD 600 and TLD 700 glow curves derived from distict mixed gamma/neutron field irradiations

    Energy Technology Data Exchange (ETDEWEB)

    Cavalieri, Tassio A.; Castro, Vinicius A.; Siqueira, Paulo T.D., E-mail: tassio.cavalieri@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Engenharia Nuclear

    2013-07-01

    In Neutron Capture Therapy, a thermal neutron beam shall impinge on a specific nuclide, such as {sup 10}B, to promote a nuclear reaction which releases the useful therapeutic energy. A nuclear reactor is usually used as the neutron source, and therefore field contaminants such as gamma and high energy neutrons are also present in the field. However, mixed field dosimetry still stands as a challenge in some cases, due to the difficulty to experimentally discriminate the dose from each field component. For the mixed field dosimetry, the International Commission on Radiation end Units (ICRU) recommends the use of detector pairs with different responses for each beam component. The TLD 600/700 pair meets this need, because these LiF detectors have different Li isotopes concentration, with distinct thermal neutron responses because {sup 6}Li presents a much higher neutron capture cross section than does {sup 7}Li for low energy neutrons. TLD 600 is {sup 6}Li enriched while TLD 700 is {sup 7}Li enriched. However, depending on the neutron spectrum presented in the mixed field, TLD 700 response to thermal neutrons cannot be disregarded. This work aims to study the difference in TLD 600 and TLD 700 glow curves when these TLDs are submitted to mixed fields of different energy spectra and components balance. The TLDs were irradiated in a pure gamma source, and in mixed fields from an AmBe sealed source and from the IPEN/MB-01 reactor. These TLDs were read and had their two main dosimetric regions analyzed to observe the differences in the glow curves of these TLDs in each irradiation. Field components discrimination was achieved through Monte Carlo simulations run with MCNP radiation transport code. (author)

  13. Optimization of Thermal Neutron Converter in SiC Sensors for Spectral Radiation Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Krolikowski, Igor; Cetnar, Jerzy [Department of Nuclear Energy, Faculty of Energy and Fuels at AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Issa, Fatima; Ferrone, Raffaello; Ottaviani, Laurent [IM2NP, UMR CNRS 7334, Aix-Marseille University, Case 231, 13397 Marseille Cedex 20 (France); Szalkai, Dora; Klix, Axel [KIT- Karlsruhe Institute of Technology, Institute of Neutron Physics and Reactor Technology, Karlsruhe 76344 (Germany); Vermeeren, Ludo [SCK-CEN, Boeretang 200, B-2400 Mol (Belgium); Lyoussi, Abdalla [CEA, DEN, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St-Paul-Lez-Durance (France); Saenger, Richard [Etudes et Productions Schlumberger, Clamart (France)

    2015-07-01

    Optimization of the neutron converter in SiC sensors is presented. The sensors are used for spectral radiation measurements of thermal and fast neutrons and optionally gamma ray at elevated temperature in harsh radiation environment. The neutron converter, which is based on 10B, allows to detect thermal neutrons by means of neutron capture reaction. Two construction of the sensors were used to measure radiation in experiments. Sensor responses collected in experiments have been reproduced by the computer tool created by authors, it allows to validate the tool. The tool creates the response matrix function describing the characteristic of the sensors and it was used for detailed analyses of the sensor responses. Obtained results help to optimize the neutron converter in order to increase thermal neutron detection. Several enhanced construction of the sensors, which includes the neutron converter based on {sup 10}B or {sup 6}Li, were proposed. (authors)

  14. First observation of trapped high-field seeking ultracold neutron spin states

    Energy Technology Data Exchange (ETDEWEB)

    Daum, M., E-mail: manfred.daum@psi.ch [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Department of Physics, University of Virginia, Charlottesville, VA 22904-4714 (United States); Fierlinger, P. [TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Franke, B. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Geltenbort, P. [ILL, Institut Laue-Langevin, Grenoble (France); Goeltl, L. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); Gutsmiedl, E. [TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Karch, J. [Institut fuer Physik, Johannes-Gutenberg-Universitaet, Mainz (Germany); Kessler, G. [TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Kirch, K. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); IPP, Institut f. Teilchenphysik, ETH Zuerich, CH-8093 Zuerich (Switzerland); Koch, H.-C.; Kraft, A.; Lauer, T. [Institut fuer Physik, Johannes-Gutenberg-Universitaet, Mainz (Germany); Lauss, B. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); Pierre, E. [LPC, Laboratoire de Physique Corpusculaire, ENSICAEN-CNRS/IN2P3, Caen (France); Pignol, G. [LPSC, Laboratoire de Physique Subatomique et de Cosmologie, UJF-CNRS/IN2P3-INPG, Grenoble (France); Reggiani, D.; Schmidt-Wellenburg, P. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); Sobolev, Yu.; Zechlau, T. [Institut fuer Physik, Johannes-Gutenberg-Universitaet, Mainz (Germany); Zsigmond, G. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland)

    2011-10-25

    Ultracold neutrons were stored in a volume, using a magnetic dipole field shutter. Radial confinement was provided by material walls. Low-field seeking neutrons were axially confined above the magnetic field. High-field seeking neutrons are trapped inside the magnetic field. They can systematically shift the measured neutron lifetime to lower values in experiments with magnetic confinement.

  15. Computational evaluation oa a neutron field facility

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Jose Julio de O.; Pazianotto, Mauricio T., E-mail: jjfilos@hotmail.com, E-mail: mpazianotto@gmail.com [Instituto Tecnologico de Aeronautica (ITA/DCTA), Sao Jose dos Campos, SP (Brazil); Federico, Claudio A.; Passaro, Angelo, E-mail: claudiofederico@ieav.cta.br, E-mail: angelo@ieav.cta.br [Instituto de Estudos Avancados (IEAv/DCTA), Sao Jose dos Campos, SP (Brazil)

    2015-07-01

    This paper describes the results of a study based on computer simulation for a realistic 3D model of Ionizing Radiation Laboratory of the Institute for Advanced Studies (IEAv) using the MCNP5 (Monte Carlo N-Particle) code, in order to guide the installing a neutron generator, produced by reaction {sup 3}H(d,n){sup 4}He. The equipment produces neutrons with energy of 14.1 MeV and 2 x 10{sup 8} n/s production rate in 4 πgeometry, which can also be used for neutron dosimetry studies. This work evaluated the spectra and neutron fluence provided on previously selected positions inside the facility, chosen due to the interest to evaluate the assessment of ambient dose equivalent so that they can be made the necessary adjustments to the installation to be consistent with the guidelines of radiation protection and radiation safety, determined by the standards of National Nuclear Energy Commission (CNEN). (author)

  16. HEIMDAL: A thermal neutron powder diffractometer with high and flexible resolution combined with SANS and neutron imaging - Designed for materials science studies at the European Spallation Source

    Science.gov (United States)

    Holm, Sonja L.; Lefmann, Kim; Henry, Paul F.; Bertelsen, Mads; Schefer, Jürg; Christensen, Mogens

    2016-08-01

    HEIMDAL will be a multi length scale neutron scattering instrument for the study of structures covering almost nine orders of magnitude from 0.01 nm to 50 mm. The instrument is accepted for construction at the European Spallation Source (ESS) and features a variable resolution thermal neutron powder diffractometer (TNPD), combined with small angle neutron scattering (SANS) and neutron imaging (NI). The instrument uses a novel combination of a cold and a thermal guide to fulfill the diverse requirements for diffraction and SANS. With an instrument length of 170 m, HEIMDAL will take advantage of the high neutron flux of the long pulse at ESS, whilst maintaining a high q-resolution due to the long flight path. The q-range coverage is up to 20 Å-1 allowing low-resolution PDF analysis. With the addition of SANS, HEIMDAL will be able to cover a uniquely broad length scale within a single instrumental set-up. HEIMDAL will be able to accommodate modern materials research in a broad variety of fields, and the task of the instrument will be to study advanced functional materials in action, as in situ and in operandi at multiple length scales (0.01-100 nm) quasi simultaneously. The instrument combines state-of-the-art neutron scattering techniques (TNPD, SANS, and NI) with the goal of studying real materials, in real time, under real conditions. This article describes the instrument design ideas, calculations and results of simulations and virtual experiments.

  17. Neutron Limit on the Strongly-Coupled Chameleon Field

    CERN Document Server

    Li, K; Cory, D G; Haun, R; Heacock, B; Huber, M G; Nsofini, J; Pushin, D A; Saggu, P; Sarenac, D; Shahi, C B; Skavysh, V; Snow, W M; Young, A R

    2016-01-01

    The physical origin of the dark energy that causes the accelerated expansion rate of the universe is one of the major open questions of cosmology. One set of theories postulates the existence of a self-interacting scalar field for dark energy coupling to matter. In the chameleon dark energy theory, this coupling induces a screening mechanism such that the field amplitude is nonzero in empty space but is greatly suppressed in regions of terrestrial matter density. However measurements performed under appropriate vacuum conditions can enable the chameleon field to appear in the apparatus, where it can be subjected to laboratory experiments. Here we report the most stringent upper bound on the free neutron-chameleon coupling in the strongly-coupled limit of the chameleon theory using neutron interferometric techniques. Our experiment sought the chameleon field through the relative phase shift it would induce along one of the neutron paths inside a perfect crystal neutron interferometer. The amplitude of the cham...

  18. Neutral Spinning Particles in Electromagnetic Fields and Neutron Interference

    Institute of Scientific and Technical Information of China (English)

    丁秀香; 梁九卿

    1994-01-01

    The dynamics of neutral spinning particles in electromagnetic fields is investigated. The phase interference of unpolarized neutron beams is reasonably interpreted as the observed spin precession in external fields instead of potential effects in the quantum physics; namely, the Aharonov-Bohm and Aharonov-Casher effects. It is also pointed out that the recent experiment claimed to be the verification of Aharonov-Casher phase with neutron interferometry, however, can be considered as a test of new anyon model.

  19. Numerical research on the anisotropic transport of thermal neutron in heterogeneous porous media with micron X-ray computed tomography

    Science.gov (United States)

    Wang, Yong; Yue, Wenzheng; Zhang, Mo

    2016-06-01

    The anisotropic transport of thermal neutron in heterogeneous porous media is of great research interests in many fields. In this paper, it is the first time that a new model based on micron X-ray computed tomography (CT) has been proposed to simultaneously consider both the separation of matrix and pore and the distribution of mineral components. We apply the Monte Carlo method to simulate thermal neutrons transporting through the model along different directions, and meanwhile detect those unreacted thermal neutrons by an array detector on the other side of the model. Therefore, the anisotropy of pore structure can be imaged by the amount of received thermal neutrons, due to the difference of rock matrix and pore-filling fluids in the macroscopic reaction cross section (MRCS). The new model has been verified by the consistent between the simulated data and the pore distribution from X-ray CT. The results show that the evaluation of porosity can be affected by the anisotropy of media. Based on the research, a new formula is developed to describe the correlation between the resolution of array detectors and the quality of imaging. The formula can be further used to analyze the critical resolution and the suitable number of thermal neutrons emitted in each simulation. Unconventionally, we find that a higher resolution cannot always lead to a better image.

  20. Study and development of new dosemeters for thermal neutrons; Estudio y desarrollo de nuevos dosimetros para neutrones termicos

    Energy Technology Data Exchange (ETDEWEB)

    Urena N, F

    1998-12-31

    An alanine-boron compound, alanine hydroborate, was synthesized and chemically characterized to be used for thermal neutrons fluence measurements. The synthesis of the compound was made by reacting the amino acid alanine with boric acid in three different media: acidic, neutral and alkaline. Physicochemical analysis showed that the alkaline medium is favorable for the synthesis of the alanine hydroborate. The compound was evaluated as a thermal neutron fluence detector by the detection of the free radical yield upon neutron thermal irradiation by Electron Paramagnetic Resonance (EPR). The present work also studies the EPR-signal response of the three preparations to thermal neutron irradiation ({phi} = 5 x 10{sup 7} n/cm{sup 2} -s). The following EPR signal parameters of the samples were investigated: peak-to-peak signal intensity vs. thermal neutron fluence {Phi} = {phi} {Delta}t ; where {Delta}t = 1, 5, 10, 20, 40, 60, 80, 90, 100, 110 and 120 h. , peak-to-peak signal intensity vs. microwave power, signal fading; repeatability, batch homogeneity, stability and zero dose response. It is concluded that these new products could be used in thermal neutron fluence estimations. (Author)

  1. Double helix boron-10 powder thermal neutron detector

    Science.gov (United States)

    Wang, Zhehui; Morris, Christopher L.; Bacon, Jeffrey D.

    2015-06-02

    A double-helix Boron-10 powder detector having intrinsic thermal neutron detection efficiency comparable to 36'' long, 2-in diameter, 2-bar Helium-3 detectors, and which can be used to replace such detectors for use in portal monitoring, is described. An embodiment of the detector includes a metallic plate coated with Boron-10 powder for generating alpha and Lithium-7 particles responsive to neutrons impinging thereon supported by insulators affixed to at least two opposing edges; a grounded first wire wound in a helical manner around two opposing insulators; and a second wire having a smaller diameter than that of the first wire, wound in a helical manner around the same insulators and spaced apart from the first wire, the second wire being positively biased. A gas, disposed within a gas-tight container enclosing the plate, insulators and wires, and capable of stopping alpha and Lithium-7 particles and generating electrons produces a signal on the second wire which is detected and subsequently related to the number of neutrons impinging on the plate.

  2. Double helix boron-10 powder thermal neutron detector

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhehui; Morris, Christopher L.; Bacon, Jeffrey D.

    2015-06-02

    A double-helix Boron-10 powder detector having intrinsic thermal neutron detection efficiency comparable to 36'' long, 2-in diameter, 2-bar Helium-3 detectors, and which can be used to replace such detectors for use in portal monitoring, is described. An embodiment of the detector includes a metallic plate coated with Boron-10 powder for generating alpha and Lithium-7 particles responsive to neutrons impinging thereon supported by insulators affixed to at least two opposing edges; a grounded first wire wound in a helical manner around two opposing insulators; and a second wire having a smaller diameter than that of the first wire, wound in a helical manner around the same insulators and spaced apart from the first wire, the second wire being positively biased. A gas, disposed within a gas-tight container enclosing the plate, insulators and wires, and capable of stopping alpha and Lithium-7 particles and generating electrons produces a signal on the second wire which is detected and subsequently related to the number of neutrons impinging on the plate.

  3. Thin film CdTe based neutron detectors with high thermal neutron efficiency and gamma rejection for security applications

    Science.gov (United States)

    Smith, L.; Murphy, J. W.; Kim, J.; Rozhdestvenskyy, S.; Mejia, I.; Park, H.; Allee, D. R.; Quevedo-Lopez, M.; Gnade, B.

    2016-12-01

    Solid-state neutron detectors offer an alternative to 3He based detectors, but suffer from limited neutron efficiencies that make their use in security applications impractical. Solid-state neutron detectors based on single crystal silicon also have relatively high gamma-ray efficiencies that lead to false positives. Thin film polycrystalline CdTe based detectors require less complex processing with significantly lower gamma-ray efficiencies. Advanced geometries can also be implemented to achieve high thermal neutron efficiencies competitive with silicon based technology. This study evaluates these strategies by simulation and experimentation and demonstrates an approach to achieve >10% intrinsic efficiency with <10-6 gamma-ray efficiency.

  4. Development of a thermal neutron detector based on scintillating fibers and silicon photomultipliers.

    Science.gov (United States)

    Barbagallo, Massimo; Cosentino, Luigi; Greco, Giuseppe; Montereali, Rosa Maria; Pappalardo, Alfio; Scirè, Carlotta; Scirè, Sergio; Vincenti, Maria Aurora; Finocchiaro, Paolo

    2010-09-01

    We propose a technique for thermal neutron detection, based on a (6)Li converter placed in front of scintillating fibers readout by means of silicon photomultipliers. Such a technique allows building cheap and compact detectors and dosimeters, thus possibly opening new perspectives in terms of granular monitoring of neutron fluxes as well as space-resolved neutron detection.

  5. H_3~(10)BO_3/ZnS(Ag) Scintillator Screen for Thermal Neutron Radiography

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    In 2011, neutron image team has completed the fabrication work of the scintillator screen for thermal neutron radiography. The neutron converter screens consist of a dispersion of H310BO3/ZnS(Ag) particles in epoxy binder. H310BO3/ZnS(Ag) screen with

  6. Nuclear Science with Thermal and Fast Neutrons at UMass Lowell

    Science.gov (United States)

    Guess, C. J.; Chowdhury, P.; Borges, N.; D'Olympia, N.; Deo, A. Y.; Harrington, T.; Hota, S.; Jackson, E. G.; Kegel, G.; Lakshmi, S.; Parker, G.; Prasher, V. S.; Recca, K.; Regan, T.; Thomas, J.; Yuan, Q.

    2011-10-01

    Increased interest in improving nuclear data for applied nuclear science has prompted new research activity at the UMass Lowell Radiation Laboratory. At the 5.5-MV CN Van de Graaff accelerator facility, the beamline for precision (n, γ) and (n,n' γ) measurements with sub-nanosecond proton beam bunches is being refurbished. A proton microbeam facility is being installed for interdisciplinary studies of materials using applied nuclear techniques. In addition, the thermal column of the 1-MW research reactor will be fitted with a new shielded area for thermal (n, γ) measurements. Neutron flux measurements, shielding calculations, and simulations are underway. Progress, status and research plans with these facilities will be discussed. This work is supported by the US Department of Energy.

  7. Neutron Star Magnetic Field as for Nonzero Photon Mass

    Institute of Scientific and Technical Information of China (English)

    WANG Qing-Wu; L(U) Xiao-Fu

    2005-01-01

    We investigate the neutron star magnetic field by the relative mean-field theory, where the photon effective mass depending on baryon density of charged particles is nonzero. This field is produced by star itself, which is the function of baryon density. The result fits the observations.

  8. Study of thermal neutron capture on /sup 32/S

    Energy Technology Data Exchange (ETDEWEB)

    Guo Taichang; Shi Zongren; Zeng Xiantang; Li Guohua; Ding Dazhao

    1985-02-01

    The ..gamma..-ray spectrum of the /sup 32/S (n,..gamma..) reaction at thermal energy measured by using a Ge(Li) detector. Among 86 ..gamma.. rays identified 23 ones are recognized as primary ..gamma..-transitions. The excitation energies of 25 levels and the decay branch ratios are deduced. Three possible levels of 7505.0, 4473.1, and 2884.6 keV were not reported previously. The neutron separation energy of /sup 33/S is determined to be 8641.7 +- 0.6 keV. The thermal neutron capture cross section of /sup 32/S is determined to be 529 +- 26 mb by summing the transition intensities to the ground state of /sup 33/S and comparing with the well known Au (n,..gamma..) cross sections. The partial capture cross section of seven primary E1 transitions are calculated by the formula of the Lane-Lynn direct capture theory and compared with measured values.

  9. The acceleration of a neutron in a static electric field

    Science.gov (United States)

    Cappelletti, R. L.

    2012-06-01

    We show that when a non-relativistic neutron travels in a static electric field, the acceleration vector operator is perpendicular to the velocity operator. Kinetic energy is conserved. A spin-dependent field term in the canonical momentum gives rise to a non-dispersive contribution to the quantum mechanical (Aharonov-Casher) phase. This motion differs from that in a static magnetic field which has no field term in the canonical momentum and no conservation of kinetic energy. For the geometry of the Aharonov-Casher effect, there is no acceleration, while in Mott-Schwinger scattering, the acceleration causes a spin-dependent change in neutron direction.

  10. Producing ultrastrong magnetic fields in neutron star mergers.

    Science.gov (United States)

    Price, D J; Rosswog, S

    2006-05-01

    We report an extremely rapid mechanism for magnetic field amplification during the merger of a binary neutron star system. This has implications for the production of the short class of gamma-ray bursts, which recent observations suggest may originate in such mergers. In detailed magnetohydrodynamic simulations of the merger process, the fields are amplified by Kelvin-Helmholtz instabilities beyond magnetar field strength and may therefore represent the strongest magnetic fields in the universe. The amplification occurs in the shear layer that forms between the neutron stars and on a time scale of only 1 millisecond, that is, long before the remnant can collapse into a black hole.

  11. In-phantom two-dimensional thermal neutron distribution for intraoperative boron neutron capture therapy of brain tumours

    Science.gov (United States)

    Yamamoto, T.; Matsumura, A.; Yamamoto, K.; Kumada, H.; Shibata, Y.; Nose, T.

    2002-07-01

    The aim of this study was to determine the in-phantom thermal neutron distribution derived from neutron beams for intraoperative boron neutron capture therapy (IOBNCT). Gold activation wires arranged in a cylindrical water phantom with (void-in-phantom) or without (standard phantom) a cylinder styrene form placed inside were irradiated by using the epithermal beam (ENB) and the mixed thermal-epithermal beam (TNB-1) at the Japan Research Reactor No 4. With ENB, we observed a flattened distribution of thermal neutron flux and a significantly enhanced thermal flux delivery at a depth compared with the results of using TNB-1. The thermal neutron distribution derived from both the ENB and TNB-1 was significantly improved in the void-in-phantom, and a double high dose area was formed lateral to the void. The flattened distribution in the circumference of the void was observed with the combination of ENB and the void-in-phantom. The measurement data suggest that the ENB may provide a clinical advantage in the form of an enhanced and flattened dose delivery to the marginal tissue of a post-operative cavity in which a residual and/or microscopically infiltrating tumour often occurs. The combination of the epithermal neutron beam and IOBNCT will improve the clinical results of BNCT for brain tumours.

  12. Thermal neutron response of a boron-coated GEM detector via GEANT4 Monte Carlo code.

    Science.gov (United States)

    Jamil, M; Rhee, J T; Kim, H G; Ahmad, Farzana; Jeon, Y J

    2014-10-22

    In this work, we report the design configuration and the performance of the hybrid Gas Electron Multiplier (GEM) detector. In order to make the detector sensitive to thermal neutrons, the forward electrode of the GEM has been coated with the enriched boron-10 material, which works as a neutron converter. A total of 5×5cm(2) configuration of GEM has been used for thermal neutron studies. The response of the detector has been estimated via using GEANT4 MC code with two different physics lists. Using the QGSP_BIC_HP physics list, the neutron detection efficiency was determined to be about 3%, while with QGSP_BERT_HP physics list the efficiency was around 2.5%, at the incident thermal neutron energies of 25meV. The higher response of the detector proves that GEM-coated with boron converter improves the efficiency for thermal neutrons detection.

  13. Pulse-shape analysis for gamma background rejection in thermal neutron radiation using CVD diamond detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kavrigin, P., E-mail: pavel.kavrigin@cividec.at [Vienna University of Technology (Austria); Finocchiaro, P., E-mail: finocchiaro@lns.infn.it [INFN Laboratori Nazionali del Sud, via S.Sofia 62, 95123 Catania (Italy); Griesmayer, E., E-mail: erich.griesmayer@cividec.at [Vienna University of Technology (Austria); Jericha, E., E-mail: jericha@ati.ac.at [Vienna University of Technology (Austria); Pappalardo, A., E-mail: apappalardo@lns.infn.it [INFN Laboratori Nazionali del Sud, via S.Sofia 62, 95123 Catania (Italy); Weiss, C., E-mail: Christina.Weiss@cern.ch [Vienna University of Technology (Austria); European Organisation for Nuclear Research (CERN), Geneva (Switzerland)

    2015-09-21

    A novel technique for the rejection of gamma background from charged-particle spectra was demonstrated using a CVD diamond detector with a {sup 6}Li neutron converter installed at a thermal neutron beamline of the TRIGA research reactor at the Atominstitut (Vienna University of Technology). Spectra of the alpha particles and tritons of {sup 6}Li(n,T){sup 4}He thermal neutron capture reaction were separated from the gamma background by a new algorithm based on pulse-shape analysis. The thermal neutron capture in {sup 6}Li is already used for neutron flux monitoring, but the ability to remove gamma background allows using a CVD diamond detector for thermal neutron counting. The pulse-shape analysis can equally be applied to all cases where the charged products of an interaction are absorbed in the diamond and to other background particles that fully traverse the detector.

  14. The study of the thermal neutron flux in the deep underground laboratory DULB-4900

    CERN Document Server

    Gavrilyuk, Yu M; Gezhaev, A M; Kazalov, V V; Kuzminov, V V; Panasenko, S I; Ratkevich, S S; Tekueva, D A; Yakimenko, S P

    2015-01-01

    We report on the study of thermal neutron flux using monitors based on mixture of ZnS(Ag) and LiF enriched with a lithium-6 isotope at the deep underground laboratory DULB-4900 at the Baksan Neutrino Observatory. An annual modulation of thermal neutron flux in DULB-4900 is observed. Experimental evidences were obtained of correlation between the long-term thermal neutron flux variations and the absolute humidity of the air in laboratory. The amplitude of the modulation exceed 5\\% of total neutron flux flux.

  15. A toroidal vortex field as an origin of the narrow mass spectrum of neutron stars

    Science.gov (United States)

    Kontorovich, V. M.

    2016-03-01

    The evolution and collapse of a gaseous, self-gravitating sphere in the presence of an internal massive toroidal vortex analogous to the vortex created by the toroidal magnetic field of the Sun is considered. When thermal pressure is taken into account, for sufficiently high masses, the instability is preserved even for a polytropic index γ neutrons differs appreciably. In the ultrarelativistic limit, an interval of stablemasses arises in a neutron gas, between a minimum mass that depends on the circulation velocity in the vortex and the critical mass for the formation of a black hole. This suggests toroidal vortex fields as a possible physical origin for the observed narrow spectrum of neutron-star masses.

  16. Development and characteristics of the HANARO ex-core neutron irradiation facility for applications in the boron neutron capture therapy field

    CERN Document Server

    Kim, M S; Jun, B J; Kim, H; Lee, B C; Hwang, Sung-Yul; Jun, Byung-Jin; Kim, Heonil; Kim, Myong-Seop; Lee, Byung-Chul

    2006-01-01

    The HANARO ex-core neutron irradiation facility was developed for various applications in the boron neutron capture therapy (BNCT) field, and its characteristics have been investigated. In order to obtain a sufficient thermal neutron flux with a low level contamination of fast neutrons and gamma-rays, a radiation filtering method is adopted. The radiation filter has been designed by using a silicon single crystal cooled by liquid nitrogen and a bismuth crystal. The installation of the main components of the irradiation facility and the irradiation room are finished. Experimental measurements of the neutron beam characteristics have been performed by using bare and cadmium covered gold foils and wires. The in-phantom neutron flux distribution was measured for a flux mapping inside the phantom. The gamma-ray dose was determined by using TLD-700 thermoluminescence dosimeters. The thermal and fast neutron fluxes and the gamma-ray dose were calculated by using the MCNP code, and they were compared with experimenta...

  17. A time-of-flight detector for thermal neutrons from radiotherapy Linacs

    Science.gov (United States)

    Conti, V.; Bartesaghi, G.; Bolognini, D.; Mascagna, V.; Perboni, C.; Prest, M.; Scazzi, S.; Mozzanica, A.; Cappelletti, P.; Frigerio, M.; Gelosa, S.; Monti, A.; Ostinelli, A.; Giannini, G.; Vallazza, E.

    2007-10-01

    Boron Neutron Capture Therapy (BNCT) is a therapeutic technique exploiting the release of dose inside the tumour cell after a fission of a 10B nucleus following the capture of a thermal neutron. BNCT could be the treatment for extended tumors (liver, stomach, lung), radio-resistant ones (melanoma) or tumours surrounded by vital organs (brain). The application of BNCT requires a high thermal neutron flux (>5×108 n cm-2 s-1) with the correct energy spectrum (neutron energy reactors. The INFN PhoNeS (Photo Neutron Source) project is trying to produce such a neutron beam with standard radiotherapy Linacs, maximizing with a dedicated photo-neutron converter the neutrons produced by Giant Dipole Resonance by a high energy ( >8 MeV) photon beam. In this framework, we have developed a real-time detector to measure the thermal neutron time-of -flight to compute the flux and the energy spectrum. Given the pulsed nature of Linac beams, the detector is a single neutron counting system made of a scintillator detecting the photon emitted after the neutron capture by the hydrogen nuclei. The scintillator signal is sampled by a dedicated FPGA clock thus obtaining the exact arrival time of the neutron itself. The paper will present the detector and its electronics, the feasibility measurements with a Varian Clinac 1800/2100CD and comparison with a Monte Carlo simulation.

  18. Three dimensional neutronic/thermal-hydraulic coupled simulation of MSR in steady state condition

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Jianjun; Wang, Chenglong [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an, Shaanxi 710049 (China); An, Hongzhen [Nuclear and Radiation Safety Center, Ministry of Environmental Protection of the People' s Republic of China, Beijing 100082 (China); Zhang, Daling, E-mail: dlzhang@mail.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an, Shaanxi 710049 (China); Qiu, Suizheng; Su, Guanghui; Tian, Wenxi; Wu, Yingwei [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an, Shaanxi 710049 (China)

    2014-02-15

    Highlights: • Developed a three dimensional coupled code for MSR. • Investigated the neutron distribution and thermal-hydraulic characters of the core under steady state condition. • Analyzed the influence of inlet temperature and inlet velocity to thermal-hydraulics characteristics of the reactor. - Abstract: MSR (molten salt reactor) uses liquid molten salt as the coolant and fuel solvent, making it the only liquid reactor among the six generation IV reactor types. As a liquid reactor the physical properties of the reactor are significantly influenced by the fuel salt flow therefore conventional analysis methods applied in solid fuel reactors are not applicable for this type of reactors. The present work developed a three dimensional neutronic/thermal-hydraulic coupled code and applied it to investigate the thermal-hydraulic characteristics of the core in steady state condition based on neutron diffusion theory and numerical heat transfer. The code consists of two group neutron diffusion equations for fast and thermal neutron fluxes and six group balance equations for delayed neutron precursors. The temperature distribution, neutron fluxes and delayed neutron precursors distribution of the core in steady state conditions was studied, and the result analyzed when inlet temperature and velocity were changed. From simulation it was found that the inlet temperature has little influence to neutron distribution however inlet velocity affects the delayed neutron distribution in steady state condition. The results provide some valuable information in design and research of this kind of reactor.

  19. Soil water content determination with cosmic-ray neutron sensor: Correcting aboveground hydrogen effects with thermal/fast neutron ratio

    Science.gov (United States)

    Tian, Zhengchao; Li, Zizhong; Liu, Gang; Li, Baoguo; Ren, Tusheng

    2016-09-01

    The cosmic-ray neutron sensor (CRNS), which estimates field scale soil water content, bridges the gap between point measurement and remote sensing. The accuracy of CRNS measurements, however, is affected by additional hydrogen pools (e.g., vegetation, snow, and rainfall interception). The objectives of this study are to: (i) evaluate the accuracy of CRNS estimates in a farmland system using depth and horizontal weighted point measurements, (ii) introduce a novel method for estimating the amounts of hydrogen from biomass and snow cover in CRNS data, and (iii) propose a simple approach for correcting the influences of aboveground hydrogen pool (expressed as aboveground water equivalent, AWE) on CRNS measurements. A field experiment was conducted in northeast China to compare soil water content results from CRNS to in-situ data with time domain reflectometry (TDR) and neutron probe (NP) in the 0-40 cm soil layers. The biomass water equivalent (BWE) and snow water equivalent (SWE) were observed to have separate linear relationships with the thermal/fast neutron ratio, and the dynamics of BWE and SWE were estimated correctly in the crop seasons and snow-covered seasons, respectively. A simple approach, which considered the AWE, AWE at calibration, and the effective measurement depth of CRNS, was introduced to correct the errors caused by BWE and SWE. After correction, the correlation coefficients between soil water contents determined by CRNS and TDR were 0.79 and 0.77 during the 2014 and 2015 crop seasons, respectively, and CRNS measurements had RMSEs of 0.028, 0.030, and 0.039 m3 m-3 in the 2014 and 2015 crop seasons and the snow-covered seasons, respectively. The experimental results also indicated that the accuracies of CRNS estimated BWE and SWE were affected by the distributions of aboveground hydrogen pools, which were related to the height of the CRNS device above ground surface.

  20. Intercomparison of radiation protection instrumentation in a pulsed neutron field

    Energy Technology Data Exchange (ETDEWEB)

    Caresana, M., E-mail: marco.caresana@polimi.it [Politecnico di Milano, CESNEF, Dipartimento di Energia, via Ponzio 34/3, 20133 Milano (Italy); Denker, A. [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner-Platz 1, D-14109 Berlin (Germany); Esposito, A. [IFNF-LNF, FISMEL, via E. Fermi 40, 00044 Frascati (Italy); Ferrarini, M. [CNAO, Via Privata Campeggi, 27100 Pavia (Italy); Golnik, N. [Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Sw. A. Boboli 8, 02-525 Warsaw (Poland); Hohmann, E. [Paul Scherrer Institut (PSI), Radiation Metrology Section, CH-5232 Villigen PSI (Switzerland); Leuschner, A. [Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22603 Hamburg (Germany); Luszik-Bhadra, M. [Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig (Germany); Manessi, G. [CERN, 1211 Geneva 23 (Switzerland); University of Liverpool, Department of Physics, L69 7ZE Liverpool (United Kingdom); Mayer, S. [Paul Scherrer Institut (PSI), Radiation Metrology Section, CH-5232 Villigen PSI (Switzerland); Ott, K. [Helmholtz-Zentrum Berlin, BESSYII, Albert-Einstein-Str.15, 12489 Berlin (Germany); Röhrich, J. [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner-Platz 1, D-14109 Berlin (Germany); Silari, M. [CERN, 1211 Geneva 23 (Switzerland); Trompier, F. [Institute for Radiological Protection and Nuclear Safety, F-92262 Fontenay aux Roses (France); Volnhals, M.; Wielunski, M. [Helmholtz Zentrum München, Ingolstädter Landstr. 1, D-85764 Neuherberg (Germany)

    2014-02-11

    In the framework of the EURADOS working group 11, an intercomparison of active neutron survey meters was performed in a pulsed neutron field (PNF). The aim of the exercise was to evaluate the performances of various neutron instruments, including commercially available rem-counters, personal dosemeters and instrument prototypes. The measurements took place at the cyclotron of the Helmholtz-Zentrum Berlin für Materialien und Energie GmbH. The cyclotron is routinely used for proton therapy of ocular tumours, but an experimental area is also available. For the therapy the machine accelerates protons to 68 MeV. The interaction of the proton beam with a thick tungsten target produces a neutron field with energy up to about 60 MeV. One interesting feature of the cyclotron is that the beam can be delivered in bursts, with the possibility to modify in a simple and flexible way the burst length and the ion current. Through this possibility one can obtain radiation bursts of variable duration and intensity. All instruments were placed in a reference position and irradiated with neutrons delivered in bursts of different intensity. The analysis of the instrument response as a function of the burst charge (the total electric charge of the protons in the burst shot onto the tungsten target) permitted to assess for each device the dose underestimation due to the time structure of the radiation field. The personal neutron dosemeters were exposed on a standard PMMA slab phantom and the response linearity was evaluated.

  1. The CLYC-6 and CLYC-7 response to γ-rays, fast and thermal neutrons

    Science.gov (United States)

    Giaz, A.; Pellegri, L.; Camera, F.; Blasi, N.; Brambilla, S.; Ceruti, S.; Million, B.; Riboldi, S.; Cazzaniga, C.; Gorini, G.; Nocente, M.; Pietropaolo, A.; Pillon, M.; Rebai, M.; Tardocchi, M.

    2016-02-01

    The crystal Cs2LiYCl6:Ce (CLYC) is a very interesting scintillator material because of its good energy resolution and its capability to identify γ-rays and fast/thermal neutrons. The crystal Cs2LiYCl6:Ce contains 6Li and 35Cl isotopes, therefore, it is possible to detect thermal neutrons through the reaction 6Li(n, α)t while 35Cl ions allow to measure fast neutrons through the reactions 35Cl(n, p)35S and 35Cl(n, α)32P. In this work two CLYC 1″×1″ crystals were used: the first crystal, enriched with 6Li at 95% (CLYC-6) is ideal for thermal neutron measurements while the second one, enriched with 7Li at >99% (CLYC-7) is suitable for fast neutron measurements. The response of CLYC scintillators was measured with different PMT models: timing or spectroscopic, with borosilicate glass or quartz window. The energy resolution, the neutron-γ discrimination and the internal activity are discussed. The capability of CLYC scintillators to discriminate γ rays from neutrons was tested with both thermal and fast neutrons. The thermal neutrons were measured with both detectors, using an AmBe source. The measurements of fast neutrons were performed at the Frascati Neutron Generator facility (Italy) where a deuterium beam was accelerated on a deuterium or on a tritium target, providing neutrons of 2.5 MeV or 14.1 MeV, respectively. The different sensitivity to thermal and fast neutrons of a CLYC-6 and of a CLYC-7 was additionally studied.

  2. The CLYC-6 and CLYC-7 response to γ-rays, fast and thermal neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Giaz, A.; Pellegri, L. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Camera, F., E-mail: franco.camera@mi.infn.it [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Università degli Studi di Milano, Physics Department, Via Celoria 16, 20133 Milano (Italy); Blasi, N.; Brambilla, S. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Ceruti, S. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Università degli Studi di Milano, Physics Department, Via Celoria 16, 20133 Milano (Italy); Million, B. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Riboldi, S. [INFN Milano, Via Celoria 16, 20133 Milano (Italy); Università degli Studi di Milano, Physics Department, Via Celoria 16, 20133 Milano (Italy); Cazzaniga, C.; Gorini, G.; Nocente, M. [University of Milano Bicocca, Physics Department, Piazza della Scienza 3, 20126 Milano (Italy); Istituto di Fisica del Plasma, Associazione EURATOM-ENEA-CNR, via Roberto Cozzi 53, 20125 Milano (Italy); Pietropaolo, A.; Pillon, M. [Associazione EURATOM-ENEA sulla Fusione ENEA C.R. Frascati, Via E. Fermi 45, 00044 Frascati, Roma (Italy); Rebai, M. [University of Milano Bicocca, Physics Department, Piazza della Scienza 3, 20126 Milano (Italy); Tardocchi, M. [Istituto di Fisica del Plasma, Associazione EURATOM-ENEA-CNR, via Roberto Cozzi 53, 20125 Milano (Italy)

    2016-02-21

    The crystal Cs{sub 2}LiYCl{sub 6}:Ce (CLYC) is a very interesting scintillator material because of its good energy resolution and its capability to identify γ-rays and fast/thermal neutrons. The crystal Cs{sub 2}LiYCl{sub 6}:Ce contains {sup 6}Li and {sup 35}Cl isotopes, therefore, it is possible to detect thermal neutrons through the reaction {sup 6}Li(n, α)t while {sup 35}Cl ions allow to measure fast neutrons through the reactions {sup 35}Cl(n, p){sup 35}S and {sup 35}Cl(n, α){sup 32}P. In this work two CLYC 1″×1″ crystals were used: the first crystal, enriched with {sup 6}Li at 95% (CLYC-6) is ideal for thermal neutron measurements while the second one, enriched with {sup 7}Li at >99% (CLYC-7) is suitable for fast neutron measurements. The response of CLYC scintillators was measured with different PMT models: timing or spectroscopic, with borosilicate glass or quartz window. The energy resolution, the neutron-γ discrimination and the internal activity are discussed. The capability of CLYC scintillators to discriminate γ rays from neutrons was tested with both thermal and fast neutrons. The thermal neutrons were measured with both detectors, using an AmBe source. The measurements of fast neutrons were performed at the Frascati Neutron Generator facility (Italy) where a deuterium beam was accelerated on a deuterium or on a tritium target, providing neutrons of 2.5 MeV or 14.1 MeV, respectively. The different sensitivity to thermal and fast neutrons of a CLYC-6 and of a CLYC-7 was additionally studied.

  3. Prompt gamma-ray analysis using cold and thermal guided neutron beams at JAERI.

    Science.gov (United States)

    Yonezawa, C

    1999-01-01

    A highly sensitive neutron-induced prompt gamma-ray analysis (PGA) system, usable at both cold and thermal neutron beam guides of JRR-3M, has been constructed. The system was designed to achieve the lowest gamma-ray background by using lithium fluoride tiles as neutron shielding, by placing the samples in a He atmosphere and by using a Ge-bismuth germanate detector system for Compton suppression. The gamma-ray spectrometer can acquire three modes of spectra simultaneously: single, Compton suppression, and pair modes. Because of the low-energy guided neutron beams and the low-background system, analytical sensitivities and detection limits better than those in usual PGA systems have been achieved. Boron and multielemental determination by a comparative standardization have been investigated, and accuracy, precision, and detection limits for the elements in various materials were evaluated. The system has been applied to the determination of B and multielements in samples of various fields such as medical, environmental, and geological sciences.

  4. Field and Thermal Characteristics of Magnetizing Fixture

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    This paper describes field modeling and thermal modeling for magnetizing fixture. As the detailed characteristics of magnetizing fixture can be obtained, the efficient design of magnetizer which produce desired magnet will be possible using our modeling. For field modeling finite-element analysis is used as part of the design and analysis process for magnetizing fixture. The thermal modeling method of magnetizing fixture resistor uses multi-lumped model with equivalent thermal resistance and thermal capacitance.

  5. Effect of magnetized phonons on electrical and thermal conductivity of neutron star crust

    Science.gov (United States)

    Baiko, D. A.

    2016-05-01

    We study electrical and thermal conductivities of degenerate electrons emitting and absorbing phonons in a strongly magnetized crystalline neutron star crust. We take into account modification of the phonon spectrum of a Coulomb solid of ions caused by a strong magnetic field. Boltzmann transport equation is solved using a generalized variational method. The ensuing 3D integrals over the transferred momenta are evaluated by two different numerical techniques, the Monte Carlo method and a regular integration over the first Brillouin zone. The results of the two numerical approaches are shown to be in a good agreement. An appreciable growth of electrical and thermal resistivities is reported at quantum and intermediate temperatures T ≲ 0.1Tp (Tp is the ion plasma temperature) in a wide range of chemical compositions and mass densities of matter even for moderately magnetized crystals ωB ˜ ωp (ωB and ωp are the ion cyclotron and plasma frequencies). This effect is due to an appearance of a soft (ω ∝ k2) phonon mode in the magnetized ion Coulomb crystal, which turns out to be easier to excite than acoustic phonons characteristic of the field-free case. These results are important for modelling magneto-thermal evolution of neutron stars.

  6. Arrangement of high-energy neutron irradiation field and shielding experiment using 4 m concrete at KENS.

    Science.gov (United States)

    Nakao, N; Yashima, H; Kawai, M; Oishi, K; Nakashima, H; Masumoto, K; Matsumura, H; Sasaki, S; Numajiri, M; Sanami, T; Wang, Q; Toyoda, A; Takahashi, K; Iijima, K; Eda, K; Ban, S; Hirayama, H; Muto, S; Nunomiya, T; Yonai, S; Rasolonjatovo, D R H; Terunuma, K; Yamauchi, K; Sarkar, P K; Kim, E; Nakamura, T; Maruhashi, A

    2005-01-01

    An irradiation field of high-energy neutrons produced in the forward direction from a thick tungsten target bombarded by 500 MeV protons was arranged at the KENS spallation neutron source facility. In this facility, shielding experiment was performed with an ordinary concrete shield of 4 m thickness assembled in the irradiation room, 2.5 m downstream from the target centre. Activation detectors of bismuth, aluminium, indium and gold were inserted into eight slots inside the shield and attenuations of neutron reaction rates were obtained by measurements of gamma-rays from the activation detectors. A MARS14 Monte Carlo simulation was also performed down to thermal energy, and comparisons between the calculations and measurements show agreements within a factor of 3. This neutron field is useful for studies of shielding, activation and radiation damage of materials for high-energy neutrons, and experimental data are useful to check the accuracies of the transmission and activation calculation codes.

  7. Thermal emission of neutron stars with internal heaters

    CERN Document Server

    Kaminker, A D; Potekhin, A Y; Yakovlev, D G

    2014-01-01

    Using 1D and 2D cooling codes we study thermal emission from neutron stars with steady state internal heaters of various intensities and geometries (blobs or spherical layers) located at different depths in the crust. The generated heat tends to propagate radially, from the heater down to the stellar core and up to the surface; it is also emitted by neutrinos. In local regions near the heater the results are well described with the 1D code. The heater's region projects onto the stellar surface forming a hot spot. There are two heat propagation regimes. In the first, conduction outflow regime (realized at heat rates $H_0 \\lesssim 10^{20}$ erg cm$^{-3}$ s$^{-1}$ or temperatures $T_\\mathrm{h} \\lesssim 10^9$ K in the heater) the thermal surface emission of the star depends on the heater's power and neutrino emission in the stellar core. In the second, neutrino outflow regime ($H_0 \\gtrsim 10^{20}$ erg cm$^{-3}$ s$^{-1}$ or $T_\\mathrm{h} \\gtrsim 10^9$ K) the surface thermal emission becomes independent of heater's...

  8. A comprehensive spectrometry study of a stray neutron radiation field in scanning proton therapy

    Science.gov (United States)

    Mares, Vladimir; Romero-Expósito, Maite; Farah, Jad; Trinkl, Sebastian; Domingo, Carles; Dommert, Martin; Stolarczyk, Liliana; Van Ryckeghem, Laurent; Wielunski, Marek; Olko, Pawel; Harrison, Roger M.

    2016-06-01

    The purpose of this study is to characterize the stray neutron radiation field in scanning proton therapy considering a pediatric anthropomorphic phantom and a clinically-relevant beam condition. Using two extended-range Bonner sphere spectrometry systems (ERBSS), Working Group 9 of the European Radiation Dosimetry Group measured neutron spectra at ten different positions around a pediatric anthropomorphic phantom irradiated for a brain tumor with a scanning proton beam. This study compares the different systems and unfolding codes as well as neutron spectra measured in similar conditions around a water tank phantom. The ten spectra measured with two ERBSS systems show a generally similar thermal component regardless of the position around the phantom while high energy neutrons (above 20 MeV) were only registered at positions near the beam axis (at 0°, 329° and 355°). Neutron spectra, fluence and ambient dose equivalent, H *(10), values of both systems were in good agreement (<15%) while the unfolding code proved to have a limited effect. The highest H *(10) value of 2.7 μSv Gy-1 was measured at 329° to the beam axis and 1.63 m from the isocenter where high-energy neutrons (E  ⩾  20 MeV) contribute with about 53%. The neutron mapping within the gantry room showed that H *(10) values significantly decreased with distance and angular position with respect to the beam axis dropping to 0.52 μSv Gy-1 at 90° and 3.35 m. Spectra at angles of 45° and 135° with respect to the beam axis measured here with an anthropomorphic phantom showed a similar peak structure at the thermal, fast and high energy range as in the previous water-tank experiments. Meanwhile, at 90°, small differences at the high-energy range were observed. Using ERBSS systems, neutron spectra mapping was performed to characterize the exposure of scanning proton therapy patients. The ten measured spectra provide precise information about the exposure of healthy organs to thermal

  9. Properties of the lithium carbonate for to be used as thermal neutrons detector; Propiedades del carbonato de litio para ser usado como detector de neutrones termicos

    Energy Technology Data Exchange (ETDEWEB)

    Herrera A, E.; Urena N, F. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    In this work the dosimetric properties of the lithium carbonate used as detecting of thermal neutrons and by means of free radicals is evaluated and presented. The studied parameters that were carried out for this detector were: intensity of the Electron paramagnetic resonance signal (EPR); reproducibility, fading of the signal to ambient temperature, stability of the signal to low temperature (0 degrees); answer of zero dose and homogeneity or reliability of the data of the detector, humidity, solar light, temperature and radio sensitivity. These parameters indicate the utility that have the detectors for the estimation of fields of neutron fluences that are applicable to capture therapies by neutron-boron and, nuclear reactors. (Author)

  10. A compact neutron scatter camera for field deployment

    CERN Document Server

    Goldsmith, John E M; Brennan, James S

    2016-01-01

    We describe a very compact (0.9 m high, 0.4 m diameter, 40 kg) battery operable neutron scatter camera designed for field deployment. Unlike most other systems, the configuration of the sixteen liquid-scintillator detection cells are arranged to provide omnidirectional (4{\\pi}) imaging with sensitivity comparable to a conventional two-plane system. Although designed primarily to operate as a neutron scatter camera for localizing energetic neutron sources, it also functions as a Compton camera for localizing gamma sources. In addition to describing the radionuclide source localization capabilities of this system, we demonstrate how it provides neutron spectra that can distinguish plutonium metal from plutonium oxide sources, in addition to the easier task of distinguishing AmBe from fission sources.

  11. Levels of 186Re populated in thermal neutron capture reaction

    Directory of Open Access Journals (Sweden)

    Bērzinš J.

    2015-01-01

    Full Text Available Levels of 186Re have been studied in the thermal neutron capture reaction with an enriched 185Re target. Evaluation of spectrum measured with GAMS5 allowed to obtain energies and intensities of more than 500 γ-lines assigned to 186Re. Most of the obtained transitions have been placed in the model-independent level scheme of the doubly odd 186Re nucleus, taking into account the available data of earlier experiments as well as the results of recent 187Re(p, d186Re reaction measurements. Structure of the 186Re low-lying levels has been analysed in terms of the particle-plus-rotor coupling model.

  12. Transparent lithiated polymer films for thermal neutron detection

    Science.gov (United States)

    Mabe, Andrew N.; Auxier, John D.; Urffer, Matthew J.; Penumadu, Dayakar; Schweitzer, George K.; Miller, Laurence F.

    2013-09-01

    Novel water-soluble 6Li loaded copolymer scintillation films have been designed and fabricated to detect thermal neutrons. Styrene and maleic anhydride were copolymerized to form an alternating copolymer, then the anhydride functionality was hydrolyzed using 6Li hydroxide. The resulting poly(styrene-co-lithium maleate) was mixed with salicylic acid as a fluor and cast as a thin film from water. The maximum 6Li loading obtained that resulted in a transparent film was 4.36% by mass (6Li to polymer). The optimum fluorescence output was obtained for 11.7% salicylic acid by mass, presumably in the form of lithium salicylate, resulting in an optimum film containing 3.85% by mass of 6Li. A facile and robust synthesis method, film fabrication protocol, photoluminescence results, and scintillation responses are reported herein.

  13. Estimation of thermal neutron fluences in the concrete of proton accelerator facilities from 36Cl production

    Science.gov (United States)

    Bessho, K.; Matsumura, H.; Miura, T.; Wang, Q.; Masumoto, K.; Hagura, H.; Nagashima, Y.; Seki, R.; Takahashi, T.; Sasa, K.; Sueki, K.; Matsuhiro, T.; Tosaki, Y.

    2007-06-01

    The thermal neutron fluence that poured into the shielding concrete of proton accelerator facilities was estimated from the in situ production of 36Cl. The thermal neutron fluences at concrete surfaces during 10-30 years of operation were in the range of 1012-1014 n/cm2. The maxima in thermal neutron fluences were observed at ≈5-15 cm in the depths analyzed for 36Cl/35Cl by AMS. These characteristics imply that thermalization of neutrons occurred inside the concrete. Compared to the several tens of MeV cyclotrons, secondary neutrons penetrate deeper into the concrete at the high-energy accelerators possessing acceleration energies of 400 MeV and 12 GeV. The attenuation length of neutrons reflects the energy spectra of secondary neutrons emitted by the nuclear reaction at the beam-loss points. Increasing the energy of secondary neutrons shifts the maximum in the thermal neutron fluences to deeper positions. The data obtained in this study will be useful for the radioactive waste management at accelerator facilities.

  14. Pulsed neutron fields measurements around a synchrotron storage ring

    Science.gov (United States)

    Caresana, Marco; Ballerini, Marcello; Ulfbeck, David Garf; Hertel, Niels; Manessi, Giacomo Paolo; Søgaard, Carsten

    2017-09-01

    A measurement campaign was performed for characterizing the neutron ambient dose equivalent, H*(10), in selected positions at ISA, Aarhus, Denmark, around the ASTRID and ASTRID2 storage rings. The neutron stray radiation field is characterized here by very intense radiation bursts with a low repetition rate, which result in a comparatively low average H*(10) rate. As a consequence, devices specifically conceived for operating in pulsed neutron fields must be employed for efficiently measuring in this radiation environment, in order to avoid severe underestimations of the H*(10) rate. The measurements were performed with the ELSE NUCLEAR LUPIN 5401 BF3-NP rem counter, a detector characterized by an innovative working principle that is not affected by dead time losses. This allowed characterizing both the H*(10) and the time structure of the radiation field in the pre-selected positions.

  15. Neutron spectrometry in mixed fields: superheated drop (bubble) detectors

    Energy Technology Data Exchange (ETDEWEB)

    D' Errico, F.; Matzke, M

    2003-07-01

    This handbook describes the instruments and methods which may be used in workplace environments in the nuclear industry, at accelerator facilities, and in aircraft, to measure: neutron spectra, photon spectra in mixed neutron gamma fields, and the direction distribution for both types of radiation. This information is needed in radiation protection research both to characterise those fields where it is important to know the dose equivalent accurately, and to investigate the performance of area survey meters and personal dosemeters in order to select the most suitable devices or to determine correction factors, or to do both. For neutron fields neither types of dosemeter, can, in general, be relied upon to give the correct answer. The spectrometry instrumentation is covered here in sufficient detail to enable an end user to select the optimum system for a particular application, and also to construct and commission the chosen system.

  16. Neutron limit on the strongly-coupled chameleon field

    Science.gov (United States)

    Li, K.; Arif, M.; Cory, D. G.; Haun, R.; Heacock, B.; Huber, M. G.; Nsofini, J.; Pushin, D. A.; Saggu, P.; Sarenac, D.; Shahi, C. B.; Skavysh, V.; Snow, W. M.; Young, A. R.; Index Collaboration

    2016-03-01

    The physical origin of the dark energy that causes the accelerated expansion rate of the Universe is one of the major open questions of cosmology. One set of theories postulates the existence of a self-interacting scalar field for dark energy coupling to matter. In the chameleon dark energy theory, this coupling induces a screening mechanism such that the field amplitude is nonzero in empty space but is greatly suppressed in regions of terrestrial matter density. However measurements performed under appropriate vacuum conditions can enable the chameleon field to appear in the apparatus, where it can be subjected to laboratory experiments. Here we report the most stringent upper bound on the free neutron-chameleon coupling in the strongly coupled limit of the chameleon theory using neutron interferometric techniques. Our experiment sought the chameleon field through the relative phase shift it would induce along one of the neutron paths inside a perfect crystal neutron interferometer. The amplitude of the chameleon field was actively modulated by varying the millibar pressures inside a dual-chamber aluminum cell. We report a 95% confidence level upper bound on the neutron-chameleon coupling β ranging from β <4.7 ×106 for a Ratra-Peebles index of n =1 in the nonlinear scalar field potential to β <2.4 ×107 for n =6 , one order of magnitude more sensitive than the most recent free neutron limit for intermediate n . Similar experiments can explore the full parameter range for chameleon dark energy in the foreseeable future.

  17. Dependence of the thermal neutron fluence at the size installations radiotherapy bunker; Dependencia de la fluencia termica de neutrones en el tamano del bunquer en instalaciones de radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Soto, X.; Amgarou, K.; Langares, J. L.; Exposito, M. R.; Gomez, F.; Domingo, C.; Sanchez-Doblado, F.

    2011-07-01

    The project aims to infer the dose deposited by neutrons in the patient treated by radiation therapy, from a measurement of the thermal neutron fluence at a selected point within the treatment room. These thermal neutrons are created when fast neutrons produced in the linac head are moderate, mainly in the walls of the bunker, and its yield depends on both the volume of the room and its geometry.

  18. Probing energy dissipation, γ-ray and neutron multiplicity in the thermal neutron-induced fission of {sup 239}Pu

    Energy Technology Data Exchange (ETDEWEB)

    Pahlavani, M.R.; Mirfathi, S.M. [University of Mazandaran, Department of Nuclear Physics, Faculty of Basic Science, Babolsar (Iran, Islamic Republic of)

    2016-04-15

    The incorporation of the four-dimensional Langevin equations led to an integrative description of fission cross-section, fragment mass distribution and the multiplicity and energy distribution of prompt neutrons and γ-rays in the thermal neutron-induced fission of {sup 239}Pu. The dynamical approach presented in this paper thoroughly reproduces several experimental observables of the fission process at low excitation energy. (orig.)

  19. Determination of thermal neutrons diffusion length in graphite; Determinacion de la Longitud de Difusion de los Neutrones Termicos en Grafito

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Fite, J.

    1959-07-01

    The diffusion length of thermal neutrons in graphite using the less possible quantity of material has been determined. The proceeding used was the measurement in a graphite pile which has a punctual source of rapid neutrons inside surrounded by a reflector medium (paraffin or water). The measurement was done in the following conditions: a) introducing an aluminium plate between both materials. b) Introducing a cadmium plate between both materials. (Author) 91 refs.

  20. ETHERNES: A new design of radionuclide source-based thermal neutron facility with large homogeneity area.

    Science.gov (United States)

    Bedogni, R; Sacco, D; Gómez-Ros, J M; Lorenzoli, M; Gentile, A; Buonomo, B; Pola, A; Introini, M V; Bortot, D; Domingo, C

    2016-01-01

    A new thermal neutron irradiation facility based on an (241)Am-Be source embedded in a polyethylene moderator has been designed, and is called ETHERNES (Extended THERmal NEutron Source). The facility shows a large irradiation cavity (45 cm × 45 cm square section, 63 cm in height), which is separated from the source by means of a polyethylene sphere acting as shadowing object. Taking advantage of multiple scattering of neutrons with the walls of this cavity, the moderation process is especially effective and allows obtaining useful thermal fluence rates from 550 to 800 cm(-2) s(-1) with a source having nominal emission rate 5.7×10(6) s(-1). Irradiation planes parallel to the cavity bottom have been identified. The fluence rate across a given plane is as uniform as 3% (or better) in a disk with 30 cm (or higher) diameter. In practice, the value of thermal fluence rate simply depends on the height from the cavity bottom. The thermal neutron spectral fraction ranges from 77% up to 89%, depending on the irradiation plane. The angular distribution of thermal neutrons is roughly isotropic, with a slight prevalence of directions from bottom to top of the cavity. The mentioned characteristics are expected to be attractive for the scientific community involved in neutron metrology, neutron dosimetry and neutron detector testing.

  1. Thermal neutron imaging through XRQA2 GAFCHROMIC films coupled with a cadmium radiator

    Energy Technology Data Exchange (ETDEWEB)

    Sacco, D. [INFN – LNF, Via E. Fermi n.40, Frascati, 00044 Roma (Italy); INAIL – DIT, Via di Fontana Candida n.1, 00040 Monteporzio Catone (Italy); Bedogni, R., E-mail: roberto.bedogni@lnf.infn.it [INFN – LNF, Via E. Fermi n.40, Frascati, 00044 Roma (Italy); Bortot, D. [Politecnico di Milano, Dipartimento di Energia, Via La Masa 34, 20156 Milano (Italy); INFN – Milano, Via Celoria16, 20133 Milano (Italy); Palomba, M. [ENEA Casaccia, Via Anguillarese, 301, S. Maria di Galeria, 00123 Roma (Italy); Pola, A. [Politecnico di Milano, Dipartimento di Energia, Via La Masa 34, 20156 Milano (Italy); INFN – Milano, Via Celoria16, 20133 Milano (Italy); Introini, M.V.; Lorenzoli, M. [Politecnico di Milano, Dipartimento di Energia, Via La Masa 34, 20156 Milano (Italy); Gentile, A. [INFN – LNF, Via E. Fermi n.40, Frascati, 00044 Roma (Italy); Strigari, L. [Laboratory of Medical Physics, Regina Elena National Cancer Institute, Via E. Chianesi 53, 00144 Roma (Italy); Pressello, C. [Department of Medical Physics, Azienda Ospedaliera San Camillo Forlanini, Circonvallazione Gianicolense 87, 00152 Roma (Italy); Soriani, A. [Laboratory of Medical Physics, Regina Elena National Cancer Institute, Via E. Chianesi 53, 00144 Roma (Italy); Gómez-Ros, J.M. [INFN – LNF, Via E. Fermi n.40, Frascati, 00044 Roma (Italy); CIEMAT, Av. Complutense 40, 28040 Madrid (Spain)

    2015-10-21

    A simple and inexpensive method to perform passive thermal neutron imaging on large areas was developed on the basis of XRQA2 GAFCHROMIC films, commonly employed for quality assurance in radiology. To enhance their thermal neutron response, the sensitive face of film was coupled with a 1 mm thick cadmium radiator, forming a sandwich. By exchanging the order of Cd filter and sensitive film with respect to the incident neutron beam direction, two different configurations (beam-Cd-film and beam-film-Cd) were identified. These configurations were tested at thermal neutrons fluence values in the range 10{sup 9}–10{sup 10} cm{sup −2}, using the ex-core radial thermal neutron column of the ENEA Casaccia – TRIGA reactor. The results are presented in this work.

  2. Thermal neutron imaging through XRQA2 GAFCHROMIC films coupled with a cadmium radiator

    Science.gov (United States)

    Sacco, D.; Bedogni, R.; Bortot, D.; Palomba, M.; Pola, A.; Introini, M. V.; Lorenzoli, M.; Gentile, A.; Strigari, L.; Pressello, C.; Soriani, A.; Gómez-Ros, J. M.

    2015-10-01

    A simple and inexpensive method to perform passive thermal neutron imaging on large areas was developed on the basis of XRQA2 GAFCHROMIC films, commonly employed for quality assurance in radiology. To enhance their thermal neutron response, the sensitive face of film was coupled with a 1 mm thick cadmium radiator, forming a sandwich. By exchanging the order of Cd filter and sensitive film with respect to the incident neutron beam direction, two different configurations (beam-Cd-film and beam-film-Cd) were identified. These configurations were tested at thermal neutrons fluence values in the range 109-1010 cm-2, using the ex-core radial thermal neutron column of the ENEA Casaccia - TRIGA reactor. The results are presented in this work.

  3. Computed tomography with thermal neutrons and gaseous position sensitive detector; Tomografia computadorizada com neutrons termicos e detetor a gas sensivel a posicao

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Maria Ines Silvani

    2001-12-01

    A third generation tomographic system using a parallel thermal neutron beam and gaseous position sensitive detector has been developed along three discrete phases. At the first one, X-ray tomographic images of several objects, using a position sensitive detector designed and constructed for this purpose have been obtained. The second phase involved the conversion of that detector for thermal neutron detection, by using materials capable to convert neutrons into detectable charged particles, testing afterwards its performance in a tomographic system by evaluation the quality of the image arising from several test-objects containing materials applicable in the engineering field. High enriched {sup 3} He, replacing the argon-methane otherwise used as filling gas for the X-ray detection, as well as, a gadolinium foil, have been utilized as converters. Besides the pure enriched {sup 3} He, its mixture with argon-methane and later on with propane, have been also tested, in order to evaluate the detector efficiency and resolution. After each gas change, the overall performance of the tomographic system using the modified detector, has been analyzed through measurements of the related parameters. This was done by analyzing the images produced by test-objects containing several materials having well known attenuation coefficients for both thermal neutrons and X-rays. In order to compare the performance of the position sensitive detector as modified to detect thermal neutrons, with that of a conventional BF{sub 3} detector, additional tomographs have been conducted using the last one. The results have been compared in terms of advantages, handicaps and complementary aspects for different kinds of radiation and materials. (author)

  4. Measurement and Simulation of Thermal Conductivity of Hafnium-Aluminum Thermal Neutron Absorber Material

    Science.gov (United States)

    Guillen, Donna Post; Harris, William H.

    2016-09-01

    A metal matrix composite (MMC) material composed of hafnium aluminide (Al3Hf) intermetallic particles in an aluminum matrix has been identified as a promising material for fast flux irradiation testing applications. This material can filter thermal neutrons while simultaneously providing high rates of conductive cooling for experiment capsules. The purpose of this work is to investigate effects of Hf-Al material composition and neutron irradiation on thermophysical properties, which were measured before and after irradiation. When performing differential scanning calorimetry (DSC) on the irradiated specimens, a large exotherm corresponding to material annealment was observed. Therefore, a test procedure was developed to perform DSC and laser flash analysis (LFA) to obtain the specific heat and thermal diffusivity of pre- and post-annealment specimens. This paper presents the thermal properties for three states of the MMC material: (1) unirradiated, (2) as-irradiated, and (3) irradiated and annealed. Microstructure-property relationships were obtained for the thermal conductivity. These relationships are useful for designing components from this material to operate in irradiation environments. The ability of this material to effectively conduct heat as a function of temperature, volume fraction Al3Hf, radiation damage, and annealing is assessed using the MOOSE suite of computational tools.

  5. Neutron Reference Benchmark Field Specification: ACRR Free-Field Environment (ACRR-FF-CC-32-CL).

    Energy Technology Data Exchange (ETDEWEB)

    Vega, Richard Manuel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Parma, Edward J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Griffin, Patrick J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Vehar, David W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-07-01

    This report was put together to support the International Atomic Energy Agency (IAEA) REAL- 2016 activity to validate the dosimetry community’s ability to use a consistent set of activation data and to derive consistent spectral characterizations. The report captures details of integral measurements taken in the Annular Core Research Reactor (ACRR) central cavity free-field reference neutron benchmark field. The field is described and an “a priori” calculated neutron spectrum is reported, based on MCNP6 calculations, and a subject matter expert (SME) based covariance matrix is given for this “a priori” spectrum. The results of 31 integral dosimetry measurements in the neutron field are reported.

  6. Magneto-rotational and thermal evolution of young neutron stars

    CERN Document Server

    Popov, S B

    2015-01-01

    After a brief review of population synthesis of close-by cooling neutron stars, I focus on the interpretation of dichotomy of spin periods of near-by coolers. The existence of two well separated groups -- short period ($\\sim$0.1-0.3 s) radio pulsars and long period ($\\sim$3-10 s) radio quiet sources, aka the Magnificent seven, -- can not be easily explained in unified models developed recently (Popov et al. 2010, Gull{\\'o}n et al. 2014). I speculate that the most natural solution of the problem can be in bimodal initial magnetic field distribution related to the existence of an additional mechanism of field generation in magnetars.

  7. Enhancement of thermal neutron attenuation of nano-B{sub 4}C, -BN dispersed neutron shielding polymer nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jaewoo, E-mail: kimj@kaeri.re.kr [Nuclear Materials Research Division, Korea Atomic Energy Research Institute, 111-989 Daeduck-daero, Yuseong-gu, Daejeon-si 305-353 (Korea, Republic of); WCI Quantum Beam based Radiation Research Center, Korea Atomic Energy Research Institute, 111-989 Daeduck-daero, Yuseong-gu, Daejeon-si 305-353 (Korea, Republic of); Missouri University Research Reactor, University of Missouri-Columbia, Columbia, MO 65211 (United States); Lee, Byung-Chul [Nuclear Reactor Core Design Division, Korea Atomic Energy Research Institute, 111-989 Daeduck-daero, Yuseong-gu, Daejeon-si 305-353 (Korea, Republic of); Uhm, Young Rang [Radioisotopes Research Division, Korea Atomic Energy Research Institute, 111-989 Daeduck-daero, Yuseong-gu, Daejeon-si 305-353 (Korea, Republic of); Miller, William H. [Missouri University Research Reactor, University of Missouri-Columbia, Columbia, MO 65211 (United States)

    2014-10-15

    Highlights: • Preparation of B{sub 4}C and BN nanopowders using a simple ball milling process. • Homogeneous dispersion and strong adhesion of nano-B{sub 4}C and -BN with polymer matrix. • Enhancement of mechanical properties of the nanocomposites compared to their micro counterparts. • Enhancement of thermal neutron attenuation of the nanocomposites. - Abstract: Nano-sized boron carbide (B{sub 4}C) and boron nitride (BN) powder were prepared using ball milling. Micro- and milled nano-powders were melt blended with high density polyethylene (HDPE) using a polymer mixer followed by hot pressing to fabricate sheet composites. The tensile and flexural strengths of HDPE nanocomposites were ∼20% higher than their micro counterparts, while those for latter decreased compared to neat HDPE. Thermal neutrons attenuation of the prepared HDPE nanocomposites was evaluated using a monochromatic ∼0.025 eV neutron beam. Thermal neutron attenuation of the HDPE nanocomposites was greatly enhanced compared to their micro counterparts at the same B-10 areal densities. Monte Carlo n-Particles (MCNP) simulations based on the lattice structure modeling also shows the similar filler size dependent thermal neutron absorption.

  8. Mapping Microwave Fields With Thermal Paper

    Science.gov (United States)

    Watkins, John L.

    1992-01-01

    Simple, inexpensive technique used to map direction and intensity of electric field in microwave resonant cavity. Technique extension of using thermal paper to map intensities (only) of microwave fields.

  9. Measurements of neutron distribution in neutrons-gamma-rays mixed field using imaging plate for neutron capture therapy.

    Science.gov (United States)

    Tanaka, Kenichi; Endo, Satoru; Hoshi, Masaharu

    2010-01-01

    The imaging plate (IP) technique is tried to be used as a handy method to measure the spatial neutron distribution via the (157)Gd(n,gamma)(158)Gd reaction for neutron capture therapy (NCT). For this purpose, IP is set in a water phantom and irradiated in a mixed field of neutrons and gamma-rays. The Hiroshima University Radiobiological Research Accelerator is utilized for this experiment. The neutrons are moderated with 20-cm-thick D(2)O to obtain suitable neutron field for NCT. The signal for IP doped with Gd as a neutron-response enhancer is subtracted with its contribution by gamma-rays, which was estimated using IP without Gd. The gamma-ray response of Gd-doped IP to non-Gd IP is set at 1.34, the value measured for (60)Co gamma-rays, in estimating the gamma-ray contribution to Gd-doped IP signal. Then measured distribution of the (157)Gd(n,gamma)(158)Gd reaction rate agrees within 10% with the calculated value based on the method that has already been validated for its reproducibility of Au activation. However, the evaluated distribution of the (157)Gd(n,gamma)(158)Gd reaction rate is so sensitive to gamma-ray energy, e.g. the discrepancy of the (157)Gd(n,gamma)(158)Gd reaction rate between measurement and calculation becomes 30% for the photon energy change from 33keV to 1.253MeV.

  10. Measurements of neutron distribution in neutrons-{gamma}-rays mixed field using imaging plate for neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Kenichi [Center of Medical Education, Sapporo Medical University, 17, Minami 1 Jo, Chuo-ku, Sapporo 060-8556 (Japan)], E-mail: tanakaken@sapmed.ac.jp; Endo, Satoru [Quantum Energy Applications, Graduate School of Engineering, Hiroshima University, 1-4-1 Kagamiyama, Higashi-Hiroshima 739-8527 (Japan); Hoshi, Masaharu [Research Institute for Radiation Biology and Medicine, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8553 (Japan)

    2010-01-15

    The imaging plate (IP) technique is tried to be used as a handy method to measure the spatial neutron distribution via the {sup 157}Gd(n,{gamma}){sup 158}Gd reaction for neutron capture therapy (NCT). For this purpose, IP is set in a water phantom and irradiated in a mixed field of neutrons and {gamma}-rays. The Hiroshima University Radiobiological Research Accelerator is utilized for this experiment. The neutrons are moderated with 20-cm-thick D{sub 2}O to obtain suitable neutron field for NCT. The signal for IP doped with Gd as a neutron-response enhancer is subtracted with its contribution by {gamma}-rays, which was estimated using IP without Gd. The {gamma}-ray response of Gd-doped IP to non-Gd IP is set at 1.34, the value measured for {sup 60}Co {gamma}-rays, in estimating the {gamma}-ray contribution to Gd-doped IP signal. Then measured distribution of the {sup 157}Gd(n,{gamma}){sup 158}Gd reaction rate agrees within 10% with the calculated value based on the method that has already been validated for its reproducibility of Au activation. However, the evaluated distribution of the {sup 157}Gd(n,{gamma}){sup 158}Gd reaction rate is so sensitive to {gamma}-ray energy, e.g. the discrepancy of the {sup 157}Gd(n,{gamma}){sup 158}Gd reaction rate between measurement and calculation becomes 30% for the photon energy change from 33 keV to 1.253 MeV.

  11. Three dimensional neutronic/thermal-hydraulic coupled simulation of MSR in transient state condition

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Jianjun [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xianning Road, 28, Xi’an 710049, Shaanxi (China); College of Mechanical and Power Engineering, China Three Gorges University, No 8, Daxue road, Yichang, Hubei 443002 (China); Zhang, Daling, E-mail: dlzhang@mail.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xianning Road, 28, Xi’an 710049, Shaanxi (China); Qiu, Suizheng; Su, Guanghui; Tian, Wenxi; Wu, Yingwei [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xianning Road, 28, Xi’an 710049, Shaanxi (China)

    2015-02-15

    Highlights: • Developed a three dimensional neutronic/thermal-hydraulic coupled transient analysis code for MSR. • Investigated the neutron distribution and thermal-hydraulic characters of the core under transient condition. • Analyzed three different transient conditions of inlet temperature drop, reactivity jump and pump coastdown. - Abstract: MSR (molten salt reactor) use liquid molten salt as coolant and fuel solvent, which was the only one liquid reactor of six Generation IV reactor types. As a liquid reactor the physical property of reactor was significantly influenced by fuel salt flow and the conventional analysis methods applied in solid fuel reactors are not applicable for this type of reactors. The present work developed a three dimensional neutronic/thermal-hydraulic coupled code investigated the neutronics and thermo-hydraulics characteristics of the core in transient condition based on neutron diffusion theory and numerical heat transfer. The code consists of two group neutron diffusion equations for fast and thermal neutron fluxes and six group balance equations for delayed neutron precursors. The code was separately validated by neutron benchmark and flow and heat transfer benchmark. Three different transient conditions was analyzed with inlet temperature drop, reactivity jump and pump coastdown. The results provide some valuable information in design and research this kind of reactor.

  12. A comparative study of the attenuation of reactor thermal neutrons in different types of concrete

    Energy Technology Data Exchange (ETDEWEB)

    Bashiter, I.I. [Zagazig Univ. (Egypt). Dept. of Physics; El-Sayed Abdo, A.; Makarious, A.S. [Atomic Energy Authority, Cairo (Egypt). Nuclear Research Centre

    1996-05-20

    This study was carried out to assess the distribution of thermal neutrons emitted directly from the core of the ET-RR-1 reactor in ordinary concrete, ilmenite concrete and ilmenite-limonite concrete shields. Measurements were carried out by using a direct beam and a cadmium filtered beam of reactor neutrons. The neutron dose distributions were measured using Li{sub 2}B{sub 4}O{sub 7}:Mn thermoluminescent dosimeters. The data obtained show that ilmenite concrete is better for slow and thermal neutron attenuation than both ordinary and ilmenite-limonite concrete. Also it was concluded that thermal neutrons emitted directly from the reactor core are highly absorbed within the first few centimeters of each type of concrete. The thickness of ilmenite concrete required to attenuate the doses of neutrons to a certain value along the beam axis for a direct reactor beam estimated to be about 75 and 57% of the shield thickness made from ordinary and ilmenite-limonite concretes, respectively. Empirical formulae were derived to calculate the neutron dose distribution in ordinary, ilmenite and ilmenite-limonite concrete shields both along and perpendicular to the beam axis for both the direct reactor neutrons and the reactor thermal neutrons. (author).

  13. The acceleration of a neutron in a static electric field

    Energy Technology Data Exchange (ETDEWEB)

    Cappelletti, R.L., E-mail: ron.cappelletti@nist.gov [NIST Center for Neutron Research, Gaithersburg, MD 20899 (United States)

    2012-06-18

    We show that when a non-relativistic neutron travels in a static electric field, the acceleration vector operator is perpendicular to the velocity operator. Kinetic energy is conserved. A spin-dependent field term in the canonical momentum gives rise to a non-dispersive contribution to the quantum mechanical (Aharonov–Casher) phase. This motion differs from that in a static magnetic field which has no field term in the canonical momentum and no conservation of kinetic energy. For the geometry of the Aharonov–Casher effect, there is no acceleration, while in Mott–Schwinger scattering, the acceleration causes a spin-dependent change in neutron direction. -- Highlights: ► Acceleration of a neutron in an E field is orthogonal to velocity. KE is conserved. ► For the Aharonov–Casher (AC) effect, acceleration is 0. ► The AC phase arises from the field term in the canonical momentum. ► In a static B field there is no field term in the canonical momentum. ► In a static B field KE is exchanged with Zeeman energy to conserve energy.

  14. Molecular structural analysis of HPRT mutations induced by thermal and epithermal neutrons in Chinese hamster ovary cells.

    Science.gov (United States)

    Kinashi, Y; Sakurai, Y; Masunaga, S; Suzuki, M; Takagaki, M; Akaboshi, M; Ono, K

    2000-09-01

    Chinese hamster ovary (CHO) cells were exposed to thermal and epithermal neutrons, and the occurrence of mutations at the HPRT locus was investigated. The Kyoto University Research Reactor (KUR), which has been improved for use in neutron capture therapy, was the neutron source. Neutron energy spectra ranging from nearly pure thermal to epithermal can be chosen using the spectrum shifters and thermal neutron filters. To determine mutant frequency and cell survival, cells were irradiated with thermal and epithermal neutrons under three conditions: thermal neutron mode, mixed mode with thermal and epithermal neutrons, and epithermal neutron mode. The mutagenicity was different among the three irradiation modes, with the epithermal neutrons showing a mutation frequency about 5-fold that of the thermal neutrons and about 1.5-fold that of the mixed mode. In the thermal neutron and mixed mode, boron did not significantly increase the frequency of the mutants at the same dose. Therefore, the effect of boron as used in boron neutron capture therapy (BNCT) is quantitatively minimal in terms of mutation induction. Over 300 independent neutron-induced mutant clones were isolated from 12 experiments. The molecular structure of HPRT mutations was determined by analysis of all nine exons by multiplex polymerase chain reaction. In the thermal neutron and mixed modes, total and partial deletions were dominant and the fraction of total deletions was increased in the presence of boron. In the epithermal neutron mode, more than half of the mutations observed were total deletions. Our results suggest that there are clear differences between thermal and epithermal neutron beams in their mutagenicity and in the structural pattern of the mutants that they induce. Mapping of deletion breakpoints of 173 partial-deletion mutants showed that regions of introns 3-4, 7/8-9 and 9-0 are sensitive to the induction of mutants by neutron irradiation.

  15. Evolutions of Neutron Stars and their Magnetic Fields

    CERN Document Server

    Bisnovatyi-Kogan, G S

    2016-01-01

    Estimations of magnetic fields of neutron stars, observed as radio and X-ray pulsars, are discussed. It is shown, that theoretical and observational values for different types of radiopulsars are in good correspondence. Radiopulsars in close binaries and millisecond pulsars, which have passed the stage of disk accretion (recycled radiopulsars), have magnetic fields 2-4 orders of magnitude smaller than ordinary single pulsars. Most probably, the magnetic field of the neutron star was screened by the infalling material. Several screening models are considered. Formation of single recycled pulsars loosing its companion is discussed. Magnetic fields of some X-ray pulsars are estimated from the cyclotron line energy. In the case of Her X-1 this estimation exceeds considerably the value of its magnetic field obtained from long term observational data related to the beam structure evolution. Another interpretation of the cyclotron feature, based on the relativistic dipole radiation mechanism, could remove this discr...

  16. The new hybrid thermal neutron facility at TAPIRO reactor for BNCT radiobiological experiments.

    Science.gov (United States)

    Esposito, J; Rosi, G; Agosteo, S

    2007-01-01

    A new thermal neutron irradiation facility, devoted to carry out both dosimetric and radiobiological studies on boron carriers, which are being developed in the framework of INFN BNCT project, has been installed at the ENEA Casaccia TAPIRO research fast reactor. The thermal column, based on an original, hybrid, neutron spectrum shifter configuration, has been recently become operative. In spite of its low power (5 kW), the new facility is able to provide a high thermal neutron flux level, uniformly distributed inside the irradiation cavity, with a quite low gamma background. The main features and preliminary benchmark measurements of the Beam-shaping assembly are here presented and discussed.

  17. Waste Package Neutron Absorber, Thermal Shunt, and Fill Gas Selection Report

    Energy Technology Data Exchange (ETDEWEB)

    V. Pasupathi

    2000-01-28

    Materials for neutron absorber, thermal shunt, and fill gas for use in the waste package were selected using a qualitative approach. For each component, selection criteria were identified; candidate materials were selected; and candidates were evaluated against these criteria. The neutron absorber materials evaluated were essentially boron-containing stainless steels. Two candidates were evaluated for the thermal shunt material. The fill gas candidates were common gases such as helium, argon, nitrogen, carbon dioxide, and dry air. Based on the performance of each candidate against the criteria, the following selections were made: Neutron absorber--Neutronit A978; Thermal shunt--Aluminum 6061 or 6063; and Fill gas--Helium.

  18. Disordered nuclear pasta, magnetic field decay, and crust cooling in neutron stars

    CERN Document Server

    Horowitz, C J; Briggs, C M; Caplan, M E; Cumming, A; Schneider, A S

    2014-01-01

    Nuclear pasta, with non-spherical shapes, is expected near the base of the crust in neutron stars. Large scale molecular dynamics simulations of pasta show long lived topological defects that could increase electron scattering and reduce both the thermal and electrical conductivities. We model a possible low conductivity pasta layer by increasing an impurity parameter Q_{imp}. Predictions of light curves for the low mass X-ray binary MXB 1659-29, assuming a large Q_{imp}, find continued late time cooling that is consistent with Chandra observations. The electrical and thermal conductivities are likely related. Therefore observations of late time crust cooling can provide insight on the electrical conductivity and the possible decay of neutron star magnetic fields (assuming these are supported by currents in the crust).

  19. MeV Neutron Production from Thermal Neutron Capture in {6}^Li Simulated with Geant4

    CERN Document Server

    Santoro, Valentina; Bentley, Phillip M

    2015-01-01

    Various Li compounds are commonly used at neutron facilities as neutron absorbers. These compounds provide one of the highest ratios of neutron attenuation to $\\gamma$-ray production. Unfortunately, the usage of these compounds can also give rise to fast neutron emission with energies up to almost 16 MeV. Historically, some details in this fast neutron production mechanism can be absent from some modeling packages under some optimization scenarios. In this work, we tested Geant4 to assess the performance of this simulation toolkit for the fast neutron generation mechanism. We compare the results of simulations performed with Geant4 to available measurements. The outcome of our study shows that results of the Geant4 simulations are in good agreement with the available measurements for $^6$Li fast neutron production, and suitable for neutron instrument background evaluation at spallation neutron sources.

  20. MeV Neutron Production from Thermal Neutron Capture in 6Li Simulated With Geant4

    Science.gov (United States)

    Santoro, Valentina; DiJulio, Douglas D.; Bentley, Phillip M.

    2016-09-01

    Various Li compounds are commonly used at neutron facilities as neutron absorbers. These compounds provide one of the highest ratios of neutron attenuation to y- ray production. Unfortunately, the usage of these compounds can also give rise to fast neutron emission with energies up to almost 16 MeV. Historically, some details in this fast neutron production mechanism can be absent from some modeling packages under some optimization scenarios. In this work, we tested Geant4 to assess the performance of this simulation toolkit for the fast neutron generation mechanism. We compare the results of simulations performed with Geant4 to available measurements. The outcome of our study shows that results of the Geant4 simulations are in good agreement with the available measurements for 6 Li fast neutron production, and suitable for neutron instrument background evaluation at spallation neutron sources.

  1. Feasibility study on epithermal neutron field for cyclotron-based boron neutron capture therapy.

    Science.gov (United States)

    Yonai, Shunsuke; Aoki, Takao; Nakamura, Takashi; Yashima, Hiroshi; Baba, Mamoru; Yokobori, Hitoshi; Tahara, Yoshihisa

    2003-08-01

    To realize the accelerator-based boron neutron capture therapy (BNCT) at the Cyclotron and Radioisotope Center of Tohoku University, the feasibility of a cyclotron-based BNCT was evaluated. This study focuses on optimizing the epithermal neutron field with an energy spectrum and intensity suitable for BNCT for various combinations of neutron-producing reactions and moderator materials. Neutrons emitted at 90 degrees from a thick (stopping-length) Ta target, bombarded by 50 MeV protons of 300 microA beam current, were selected as a neutron source, based on the measurement of angular distributions and neutron energy spectra. As assembly composed of iron, AlF3/Al/6LiF, and lead was chosen as moderators, based on the simulation trials using the MCNPX code. The depth dose distributions in a cylindrical phantom, calculated with the MCNPX code, showed that, within 1 h of therapeutic time, the best moderator assembly, which is 30-cm-thick iron, 39-cm-thick AlF3/Al/6LiF, and 1-cm-thick lead, provides an epithermal neutron flux of 0.7 x 10(9) [n cm(-2) s(-1)]. This results in a tumor dose of 20.9 Gy-eq at a depth of 8 cm in the phantom, which is 6.4 Gy-eq higher than that of the Brookhaven Medical Research Reactor at the equivalent condition of maximum normal tissue tolerance. The beam power of the cyclotron is 15 kW, which is much lower than other accelerator-based BNCT proposals.

  2. Deformed neutron stars due to strong magnetic field in terms of relativistic mean field theories

    Science.gov (United States)

    Yanase, Kota; Yoshinaga, Naotaka

    2014-09-01

    Some observations suggest that magnetic field intensity of neutron stars that have particularly strong magnetic field, magnetars, reaches values up to 1014-15G. It is expected that there exists more strong magnetic field of several orders of magnitude in the interior of such stars. Neutron star matter is so affected by magnetic fields caused by intrinsic magnetic moments and electric charges of baryons that masses of neutron stars calculated by using Tolman-Oppenheimer-Volkoff equation is therefore modified. We calculate equation of state (EOS) in density-dependent magnetic field by using sigma-omega-rho model that can reproduce properties of stable nuclear matter in laboratory Furthermore we calculate modified masses of deformed neutron stars.

  3. Neutron spectrometry and dosimetry in 100 and 300 MeV quasi-mono-energetic neutron field at RCNP, Osaka University, Japan

    Science.gov (United States)

    Mares, Vladimir; Trinkl, Sebastian; Iwamoto, Yosuke; Masuda, Akihiko; Matsumoto, Tetsuro; Hagiwara, Masayuki; Satoh, Daiki; Yashima, Hiroshi; Shima, Tatsushi; Nakamura, Takashi

    2017-09-01

    This paper describes the results of neutron spectrometry and dosimetry measurements using an extended range Bonner Sphere Spectrometer (ERBSS) with 3He proportional counter performed in quasi-mono-energetic neutron fields at the ring cyclotron facility of the Research Center for Nuclear Physics (RCNP), Osaka University, Japan. Using 100 MeV and 296 MeV proton beams, neutron fields with nominal peak energies of 96 MeV and 293 MeV were generated via 7Li(p,n)7Be reactions. Neutrons produced at 0° and 25° emission angles were extracted into the 100 m long time-of-flight (TOF) tunnel, and the energy spectra were measured at a distance of 35 m from the target. To deduce the corresponding neutron spectra from thermal to the nominal maximum energy, the ERBSS data were unfolded using the MSANDB unfolding code. At high energies, the neutron spectra were also measured by means of the TOF method using NE213 organic liquid scintillators. The results are discussed in terms of ambient dose equivalent, H*(10), and compared with the readings of other instruments operated during the experiment.

  4. Spot--like Structures of Neutron Star Surface Magnetic Fields

    CERN Document Server

    Geppert, U; Gil, J

    2003-01-01

    There is growing evidence, based on both X-ray and radio observations of isolated neutron stars, that besides the large--scale (dipolar) magnetic field, which determines the pulsar spin--down behaviour, small--scale poloidal field components are present, which have surface strengths one to two orders of magnitude larger than the dipolar component. We argue in this paper that the Hall--effect can be an efficient process in producing such small--scale field structures just above the neutron star surface. It is shown that due to a Hall--drift induced instability, poloidal magnetic field structures can be generated from strong subsurface toroidal fields, which are the result of either a dynamo or a thermoelectric instability acting at early times of a neutron star's life. The geometrical structure of these small--scale surface anomalies of the magnetic field resembles that of some types of ``star--spots''. The magnetic field strength and the length--scales are comparable with values that can be derived from vario...

  5. Identification of the fast and thermal neutron characteristics of transuranic waste drums

    Energy Technology Data Exchange (ETDEWEB)

    Storm, B.H. Jr.; Bramblett, R.L. [Lockheed Martin Specialty Components, Largo, FL (United States); Hensley, C. [Oak Ridge National Lab., TN (United States)

    1997-11-01

    Fissile and spontaneously fissioning material in transuranic waste drums can be most sensitively assayed using an active and passive neutron assay system such as the Active Passive Neutron Examination and Assay. Both the active and the passive assays are distorted by the presence of the waste matrix and containerization. For accurate assaying, this distortion must be characterized and accounted for. An External Matrix Probe technique has been developed that accomplishes this task. Correlations between in-drum neutron flux measurements and monitors in the Active Passive Neutron Examination and Assay chamber with various matrix materials provide a non-invasive means of predicting the thermal neutron flux in waste drums. Similarly, measures of the transmission of fast neutrons emitted from sources in the drum. Results obtained using the Lockheed Martin Specialty Components Active Passive Neutron Examination and Assay system are discussed. 12 figs., 1 tab.

  6. Magnetic fields in mixed neutron-star-plus-wormhole systems

    CERN Document Server

    Aringazin, Ascar; Folomeev, Vladimir; Kleihaus, Burkhard; Kunz, Jutta

    2014-01-01

    We consider mixed configurations consisting of a wormhole filled by a strongly magnetized isotropic or anisotropic neutron fluid. The nontrivial topology of the spacetime is allowed by the presence of exotic matter. By comparing these configurations with ordinary magnetized neutron stars, we clarify the question of how the presence of the nontrivial topology influences the magnetic field distribution inside the fluid. In the case of an anisotropic fluid, we find new solutions describing configurations, where the maximum of the fluid density is shifted from the center. A linear stability analysis shows that these mixed configurations are unstable.

  7. Evaluating the 239Pu Prompt Fission Neutron Spectrum Induced by Thermal to 30 MeV Neutrons

    Directory of Open Access Journals (Sweden)

    Neudecker D.

    2016-01-01

    Full Text Available We present a new evaluation of the 239Pu prompt fission neutron spectrum (PFNS induced by thermal to 30 MeV neutrons. Compared to the ENDF/B-VII.1 evaluation, this one includes recently published experimental data as well as an improved and extended model description to predict PFNS. For instance, the pre-equilibrium neutron emission component to the PFNS is considered and the incident energy dependence of model parameters is parametrized more realistically. Experimental and model parameter uncertainties and covariances are estimated in detail. Also, evaluated covariances are provided between all PFNS at different incident neutron energies. Selected evaluation results and first benchmark calculations using this evaluation are briefly discussed.

  8. Evaluating the 239Pu Prompt Fission Neutron Spectrum Induced by Thermal to 30 MeV Neutrons

    Science.gov (United States)

    Neudecker, D.; Talou, P.; Kawano, T.; Kahler, A. C.; Rising, M. E.; White, M. C.

    2016-03-01

    We present a new evaluation of the 239Pu prompt fission neutron spectrum (PFNS) induced by thermal to 30 MeV neutrons. Compared to the ENDF/B-VII.1 evaluation, this one includes recently published experimental data as well as an improved and extended model description to predict PFNS. For instance, the pre-equilibrium neutron emission component to the PFNS is considered and the incident energy dependence of model parameters is parametrized more realistically. Experimental and model parameter uncertainties and covariances are estimated in detail. Also, evaluated covariances are provided between all PFNS at different incident neutron energies. Selected evaluation results and first benchmark calculations using this evaluation are briefly discussed.

  9. Simultaneous measurement of fission fragments and prompt neutrons for thermal neutron-induced fission of U-235

    Energy Technology Data Exchange (ETDEWEB)

    Nishio, Katsuhisa; Yamamoto, Hideki; Kimura, Itsuro; Nakagome, Yoshihiro [Kyoto Univ. (Japan)

    1997-03-01

    Simultaneous measurement of fission fragments and prompt neutrons following the thermal neutron induced fission of U-235 has been performed in order to obtain the neutron multiplicity (v) and its emission energy ({eta}) against the specified mass (m{sup *}) and the total kinetic energy (TKE). The obtained value of -dv/dTKE(m{sup *}) showed a saw-tooth distribution. The average neutron energy <{eta}>(m{sup *}) had a distribution with a reflection symmetry around the half mass division. The measurement also gave the level density parameters of the specified fragment, a(m{sup *}), and this parameters showed a saw-tooth trend too. The analysis by a phenomenological description of this parameters including the shell and collective effects suggested the existence of a collective motion of the fission fragments. (author)

  10. Neutron spectroscopy by thermalization light yield measurement in a composite heterogeneous scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Shi, T.; Nattress, J.; Mayer, Michael F.; Lin, M-W; Jovanovic, Igor

    2016-12-11

    An exothermic neutron capture reaction can be used to uniquely identify neutrons in particle detectors. With the use of a capture-gated coincidence technique, the sequence of scatter events that lead to neutron thermalization prior to the neutron capture can also be used to measure neutron energy. We report on the measurement of thermalization light yield via a time-of-flight technique in a polyvinyl toluene-based scintillator EJ-290 within a heterogeneous composite detector that also includes 6Li-doped glass scintillator. The thermalization light output exhibits a strong correlation with neutron energy because of the preference for near-complete energy deposition prior to the 6Li(n,t)4He neutron capture reaction. The nonproportionality of the light yield from nuclear recoils contributes to the observed broadening of the distribution of thermalization light output. The nonproportional dependence of the scintillation light output in the EJ-290 scintillator as a function of proton recoil energy has been characterized in the range of 0.3–14.1 MeV via the Birks parametrization through a combination of time-of-flight measurement and previously conducted measurements with Monoenergetic neutron sources.

  11. Measurement of thermal neutron cross section for {sup 241}Am(n,f) reaction

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Katsuhei; Yamamoto, Shuji; Fujita, Yoshiaki [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst.; Miyoshi, Mitsuharu; Kimura, Itsuro; Kanno, Ikuo; Shinohara, Nobuo

    1997-03-01

    Making use of a standard neutron spectrum field with a pure Maxwellian distribution, the thermal neutron cross section for the {sup 241}Am(n,f) reaction has been measured relative to the reference value of 586.2b for the {sup 235U}(n,f) reaction. For the present measurement, electrodeposited layers of {sup 241}Am and {sup 235}U have been employed as back-to-back type double fission chambers. The present result at neutron energy of 0.0253 eV is 3.15 {+-} 0.097b. The ENDF/B-VI data is in good agreement with the present value, while the JENDL-3.2 data is lower by 4.2%. The evaluated data in JEF-2.2 and by Mughabghab are higher by 0.9% and 1.6%, respectively than the present result. The ratios of the earlier experimental data to the present value are distributed between 0.89 and 1.02. (author)

  12. Neutronic and thermal-hydraulic coupling for 3D reactor core modeling combining MCB and fluent

    Directory of Open Access Journals (Sweden)

    Królikowski Igor P.

    2015-09-01

    Full Text Available Three-dimensional simulations of neutronics and thermal hydraulics of nuclear reactors are a tool used to design nuclear reactors. The coupling of MCB and FLUENT is presented, MCB allows to simulate neutronics, whereas FLUENT is computational fluid dynamics (CFD code. The main purpose of the coupling is to exchange data such as temperature and power profile between both codes. Temperature required as an input parameter for neutronics is significant since cross sections of nuclear reactions depend on temperature. Temperature may be calculated in thermal hydraulics, but this analysis needs as an input the power profile, which is a result from neutronic simulations. Exchange of data between both analyses is required to solve this problem. The coupling is a better solution compared to the assumption of estimated values of the temperatures or the power profiles; therefore the coupled analysis was created. This analysis includes single transient neutronic simulation and several steady-state thermal simulations. The power profile is generated in defined points in time during the neutronic simulation for the thermal analysis to calculate temperature. The coupled simulation gives information about thermal behavior of the reactor, nuclear reactions in the core, and the fuel evolution in time. Results show that there is strong influence of neutronics on thermal hydraulics. This impact is stronger than the impact of thermal hydraulics on neutronics. Influence of the coupling on temperature and neutron multiplication factor is presented. The analysis has been performed for the ELECTRA reactor, which is lead-cooled fast reactor concept, where the coolant fl ow is generated only by natural convection

  13. Characterisation of neutron fields: challenges in assessing the directional distribution.

    Science.gov (United States)

    Cauwels, Vanessa; Vanhavere, Filip; Reginatto, Marcel

    2014-10-01

    The SCK·CEN has carried out neutron field characterisation campaigns at several nuclear reactors. The main goal of these measurement campaigns was to evaluate the performance of different neutron personal dosemeters. To be able to evaluate the performance of neutron personal dosemeters in terms of Hp(10), knowledge of the directional distribution is indispensable. This distribution was estimated by placing several personal dosemeters on all six sides of a slab phantom. The interpretation and conversion of this information into a reliable value for Hp(10) requires great care. The data were analysed using three methods. In the first approach, a linear interpolation was performed on three perpendicular axes. In the other two approaches, an icosahedron was used to model the angle of incidence of the neutrons and a linear interpolation or a Bayesian analysis was performed. This study describes the limitations and advantages of each of these methods and provides recommendations for their use to estimate the personal dose equivalent Hp(10) for neutron dosimetry. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Report on Thermal Neutron Diffusion Length Measurement in Reactor Grade Graphite Using MCNP and COMSOL Multiphysics

    CERN Document Server

    Mirfayzi, S R

    2013-01-01

    Neutron diffusion length in reactor grade graphite is measured both experimentally and theoretically. The experimental work includes Monte Carlo (MC) coding using 'MCNP' and Finite Element Analysis (FEA) coding suing 'COMSOL Multiphysics' and Matlab. The MCNP code is adopted to simulate the thermal neutron diffusion length in a reactor moderator of 2m x 2m with slightly enriched uranium ($^{235}U$), accompanied with a model designed for thermal hydraulic analysis using point kinetic equations, based on partial and ordinary differential equation. The theoretical work includes numerical approximation methods including transcendental technique to illustrate the iteration process with the FEA method. Finally collision density of thermal neutron in graphite is measured, also specific heat relation dependability of collision density is also calculated theoretically, the thermal neutron diffusion length in graphite is evaluated at $50.85 \\pm 0.3cm$ using COMSOL Multiphysics and $50.95 \\pm 0.5cm$ using MCNP. Finally ...

  15. Impact of thermal and intermediate energy neutrons on the semiconductor memories for the CERN accelerators

    CERN Document Server

    Cecchetto, Matteo; Gerardin, Simone

    A wide quantity of SRAM memories are employed along the Large Hadron Collider (LHC), the main CERN accelerator, and they are subjected to high levels of ionizing radiations which compromise the reliability of these devices. The Single Event Effect (SEE) qualification for components to be used in the complex high-energy accelerator at CERN relies on the characterization of two cross sections: 200-MeV protons and thermal neutrons. However, due to cost and time constraints, it is not always possible to characterize the SEE response of components to thermal neutrons, which is often regarded as negligible for components without borophosphosilicate glass (BPSG). Nevertheless, as recent studies show, the sensitivity of deep sub-micron technologies to thermal neutrons has increased owing to the presence of Boron 10 as a dopant and contact contaminant. The very large thermal neutron fluxes relative to high-energy hadron fluxes in some of the heavily shielded accelerator areas imply that even comparatively small therm...

  16. The Experimental Determination of Thermal Neutron Flux in the Radiochemistry Curriculum

    Science.gov (United States)

    Grant, Patrick M.

    1977-01-01

    Describes an experiment for determining the thermal neutron flux of the light-water nuclear reactor at the University of California, Irvine. The difficulty of the activity can be varied to match the student's level of proficiency. (SL)

  17. Compositional variability across Mercury's surface revealed by MESSENGER measurements of variations in thermal neutron count rates

    Science.gov (United States)

    Peplowski, P. N.; Lawrence, D. J.; Goldsten, J. O.; Nittler, L. R.; Solomon, S. C.

    2013-12-01

    Measurements by MESSENGER's Gamma-Ray and Neutron Spectrometer (GRNS) have revealed variations in the flux of thermal neutrons across Mercury's northern hemisphere. These variations are interpreted to originate from spatial variations in surface elemental composition. In particular, the measurements are sensitive to the near-surface abundances of elements that absorb thermal neutrons, including major rock-forming elements such as Fe and Ti, minor elements such as Mn and Cl, and rare-earth elements such as Gd and Sm. We have constructed a map of thermal neutron variability across the surface and compared it with known variations in elemental composition and with the distribution of geologic units. Development of the map included the derivation of the macroscopic thermal neutron absorption cross section across the surface, a quantity whose value and variability provides useful constraints on the formation and geochemical evolution of Mercury's crust. Finally, by combining the thermal neutron measurements with previously reported elemental measurements from the GRNS and MESSENGER's X-Ray Spectrometer, we have derived constraints on the abundances of neutron-absorbing elements, including previously unreported limits for some minor and rare-earth elements.

  18. Calculation of thermal neutron self-shielding correction factors for aqueous bulk sample prompt gamma neutron activation analysis using the MCNP code

    Energy Technology Data Exchange (ETDEWEB)

    Nasrabadi, M.N. [Department of Physics, Faculty of Science, University of Kashan, Km. 6, Ravand Road, Kashan (Iran, Islamic Republic of)], E-mail: mnnasri@kashanu.ac.ir; Jalali, M. [Isfahan Nuclear Science and Technology Research Institute, Atomic Energy organization of Iran (Iran, Islamic Republic of); Mohammadi, A. [Department of Physics, Faculty of Science, University of Kashan, Km. 6, Ravand Road, Kashan (Iran, Islamic Republic of)

    2007-10-15

    In this work thermal neutron self-shielding in aqueous bulk samples containing neutron absorbing materials is studied using bulk sample prompt gamma neutron activation analysis (BSPGNAA) with the MCNP code. The code was used to perform three dimensional simulations of a neutron source, neutron detector and sample of various material compositions. The MCNP model was validated against experimental measurements of the neutron flux performed using a BF{sub 3} detector. Simulations were performed to predict thermal neutron self-shielding in aqueous bulk samples containing neutron absorbing solutes. In practice, the MCNP calculations are combined with experimental measurements of the relative thermal neutron flux over the sample's surface, with respect to a reference water sample, to derive the thermal neutron self-shielding within the sample. The proposed methodology can be used for the determination of the elemental concentration of unknown aqueous samples by BSPGNAA where knowledge of the average thermal neutron flux within the sample volume is required.

  19. Neutronics and thermal hydraulics feedback models of the Harwell materials testing reactors DIDO and PLUTO: I Neutronics analysis

    Energy Technology Data Exchange (ETDEWEB)

    Javadi, M.

    1986-10-01

    Neutronics modelling of the Harwell MTRs DIDO and PLUTO has been achieved in the WIMS-E framework using (r,z) and (x,y) two dimensional diffusion theory. The modelling takes into account fuel burnup and the presence of the coarse control arms and experimental rigs. The modelling is validated by comparisons with measurements of thermal and fast flux distributions.

  20. Torsional oscillations of neutron stars with highly tangled magnetic fields

    CERN Document Server

    Sotani, Hajime

    2015-01-01

    To determine the frequencies of magnetic oscillations in the neutron stars with highly tangled magnetic fields, we derive the perturbation equations. We assume that the field strength of the global magnetic structure is so small that such fields are negligible compared with the tangled fields, which may still be far from a realistic configuration. Then, we systematically examine the spectra of the magnetic oscillations, as varying the magnetic field strength and stellar mass. The frequencies without crust elasticity are completely proportional to the strength of magnetic field, whose proportionality constant depends strongly on the stellar mass. On the other hand, the oscillation spectra with crust elasticity become more complicated, where the frequencies even for weak magnetic fields are different from the crustal torsional oscillations without magnetic fields. For discussing the spectra, the critical field strength can play an important role, which is determined in such a way that the shear velocity is equi...

  1. Tables for simplifying calculations of activities produced by thermal neutrons

    Science.gov (United States)

    Senftle, F.E.; Champion, W.R.

    1954-01-01

    The method of calculation described is useful for the types of work of which examples are given. It is also useful in making rapid comparison of the activities that might be expected from several different elements. For instance, suppose it is desired to know which of the three elements, cobalt, nickel, or vanadium is, under similar conditions, activated to the greatest extent by thermal neutrons. If reference is made to a cross-section table only, the values may be misleading unless properly interpreted by a suitable comparison of half-lives and abundances. In this table all the variables have been combined and the desired information can be obtained directly from the values of A 3??, the activity produced per gram per second of irradiation, under the stated conditions. Hence, it is easily seen that, under similar circumstances of irradiation, vanadium is most easily activated even though the cross section of one of the cobalt isotopes is nearly five times that of vanadium and the cross section of one of the nickel isotopes is three times that of vanadium. ?? 1954 Societa?? Italiana di Fisica.

  2. Thermal conductivity of the neutron star crust: A reappraisal

    CERN Document Server

    Abbar, Sajad; Duan, Huaiyu; Reddy, Sanjay

    2015-01-01

    We use classical and quantum Monte Carlo techniques to study the static structure function $S(q)$ of a one-component ion lattice and use it to calculate the thermal conductivity $\\kappa$ of high-density solid matter expected in the neutron star crust. We also calculate the phonon spectrum using the dynamic-matrix method and use it to obtain $\\kappa$ in the one-phonon approximation. We compare the results obtained with these methods and assess the validity of some commonly used approximations in the literature. We find that quantum effects became relevant for the calculation of $\\kappa$ when the temperature $T\\lesssim 0.3~\\Omega_\\mathrm{P}$, where $\\Omega_\\mathrm{P}$ is the ion plasma frequency. Dynamical information beyond the static structure becomes relevant when $T\\lesssim 0.1~\\Omega_\\mathrm{P}$. We discuss the implications of these findings for calculations of $\\kappa$ in multi-component systems and identify strategies for using Monte Carlo techniques in future work.

  3. Feasibility of culvert IED detection using thermal neutron activation

    Science.gov (United States)

    Faust, Anthony A.; McFee, John E.; Clifford, Edward T. H.; Andrews, Hugh Robert; Mosquera, Cristian; Roberts, William C.

    2012-06-01

    Bulk explosives hidden in culverts pose a serious threat to the Canadian and allied armies. Culverts provide an opportunity to conceal insurgent activity, avoid the need for detectable surface disturbances, and limit the applicability of conventional sub-surface sensing techniques. Further, in spite of the large masses of explosives that can be employed, the large sensor{target separation makes detection of the bulk explosive content challeng- ing. Defence R&D Canada { Sueld and Bubble Technology Industries have been developing thermal neutron activation (TNA) sensors for detection of buried bulk explosives for over 15 years. The next generation TNA sensor, known as TNA2, incorporates a number of improvements that allow for increased sensor-to-target dis- tances, making it potentially feasible to detect large improvised explosive devices (IEDs) in culverts using TNA. Experiments to determine the ability of TNA2 to detect improvised explosive devices in culverts are described, and the resulting signal levels observed for relevant quantities of explosives are presented. Observations conrm that bulk explosives detection using TNA against a culvert-IED is possible, with large charges posing a detection challenge at least as dicult as that of a deeply buried anti-tank landmine. Because of the prototype nature of the TNA sensor used, it is not yet possible to make denitive statements about the absolute sensitivity or detection time. Further investigation is warranted.

  4. Abnormal changes in the density of thermal neutron flux in biocenoses near the earth surface.

    Science.gov (United States)

    Plotnikova, N V; Smirnov, A N; Kolesnikov, M V; Semenov, D S; Frolov, V A; Lapshin, V B; Syroeshkin, A V

    2007-04-01

    We revealed an increase in the density of thermal neutron flux in forest biocenoses, which was not associated with astrogeophysical events. The maximum spike of this parameter in the biocenosis reached 10,000 n/(sec x m2). Diurnal pattern of the density of thermal neutron flux depended only on the type of biocenosis. The effects of biomodulation of corpuscular radiation for balneology are discussed.

  5. Report on Thermal Neutron Diffusion Length Measurement in Reactor Grade Graphite Using MCNP and COMSOL Multiphysics

    OpenAIRE

    2013-01-01

    Neutron diffusion length in reactor grade graphite is measured both experimentally and theoretically. The experimental work includes Monte Carlo (MC) coding using 'MCNP' and Finite Element Analysis (FEA) coding suing 'COMSOL Multiphysics' and Matlab. The MCNP code is adopted to simulate the thermal neutron diffusion length in a reactor moderator of 2m x 2m with slightly enriched uranium ($^{235}U$), accompanied with a model designed for thermal hydraulic analysis using point kinetic equations...

  6. Transport calculation of thermal and cold neutrons using NMTC/JAERI-MCNP4A code system

    Energy Technology Data Exchange (ETDEWEB)

    Iga, Kiminori [Kyushu Univ., Fukuoka (Japan); Takada, Hiroshi; Nagao, Tadashi

    1998-01-01

    In order to investigate the applicability of the NMTC/JAERI-MCNP4A code system to the neutronics design study in the neutron science research project of JAERI, transport calculations of thermal and cold neutrons are performed with the code system on a spallation neutron source composed of light water cooled tantalum target with a moderator and a reflector system. The following neutronic characteristics are studied in the calculation : the variation of the intensity of neutrons emitted from a light water moderator or a liquid hydrogen with/without the B{sub 4}C decoupler, which are installed to produce sharp pulse, and that dependent on the position of external source neutrons in the tantalum target. The calculated neutron energy spectra are reproduced well by the semi-empirical formula with the parameter values reliable in physical meanings. It is found to be necessary to employ proper importance sampling technique in the statistics. It is confirmed from this work that the NMTC/JAERI-MCNP4A code system is applicable to the neutronics design study of spallation neutron sources proposed for the neutron science research project. (author)

  7. Near-field thermal electromagnetic transport

    CERN Document Server

    Edalatpour, Sheila

    2015-01-01

    A general near-field thermal electromagnetic transport formalism that is independent of the size, shape and number of heat sources is derived. The formalism is based on fluctuational electrodynamics, where fluctuating currents due to thermal agitation are added into Maxwell's curl equations, and is thus valid for heat sources in local thermodynamic equilibrium. Using a volume integral formulation, it is shown that the proposed formalism is a generalization of the classical electromagnetic scattering framework in which thermal emission is implicitly assumed to be negligible. The near-field thermal electromagnetic transport formalism is afterwards applied to a problem involving three spheres exchanging thermal radiation, where all multipolar interactions are taken into account. Using the thermal discrete dipole approximation, it is shown that depending on the dielectric function, the presence of a third sphere slightly affects the spatial distribution of power absorbed compared to the two-sphere case. The forma...

  8. Experimental characterization of HOTNES: A new thermal neutron facility with large homogeneity area

    Science.gov (United States)

    Bedogni, R.; Sperduti, A.; Pietropaolo, A.; Pillon, M.; Pola, A.; Gómez-Ros, J. M.

    2017-01-01

    A new thermal neutron irradiation facility, called HOTNES (HOmogeneous Thermal NEutron Source), was established in the framework of a collaboration between INFN-LNF and ENEA-Frascati. HOTNES is a polyethylene assembly, with about 70 cmx70 cm square section and 100 cm height, including a large, cylindrical cavity with diameter 30 cm and height 70 cm. The facility is supplied by a 241Am-B source located at the bottom of this cavity. The facility was designed in such a way that the iso-thermal-fluence surfaces, characterizing the irradiation volume, coincide with planes parallel to the cavity bottom. The thermal fluence rate across a given isofluence plane is as uniform as 1% on a disk with 30 cm diameter. Thermal fluence rate values from about 700 cm-2 s-1 to 1000 cm-2 s-1 can be achieved. The facility design, previously optimized by Monte Carlo simulation, was experimentally verified. The following techniques were used: gold activation foils to assess the thermal fluence rate, semiconductor-based active detector for mapping the irradiation volume, and Bonner Sphere Spectrometer to determine the complete neutron spectrum. HOTNES is expected to be attractive for the scientific community involved in neutron metrology, neutron dosimetry and neutron detector testing.

  9. Intercomparison of radiation protection instrumentation in a pulsed neutron field

    CERN Document Server

    Caresana, M; Esposito, A; Ferrarini, M; Golnik, N; Hohmann, E; Leuschner, A; Luszik-Bhadra, M; Manessi, G; Mayer, S; Ott, K; Röhrich, J; Silari, M; Trompier, F; Volnhals, M; Wielunski, M

    2014-01-01

    In the framework of the EURADOS working group 11, an intercomparison of active neutron survey meters was performed in a pulsed neutron field (PNF). The aim of the exercise was to evaluate the performances of various neutron instruments, including commercially available rem-counters, personal dosemeters and instrument prototypes. The measurements took place at the cyclotron of the Helmholtz-Zentrum Berlin für Materialien und Energie GmbH. The cyclotron is routinely used for proton therapy of ocular tumours, but an experimental area is also available. For the therapy the machine accelerates protons to 68 MeV. The interaction of the proton beam with a thick tungsten target produces a neutron field with energy up to about 60 MeV. One interesting feature of the cyclotron is that the beam can be delivered in bursts, with the possibility to modify in a simple and flexible way the burst length and the ion current. Through this possibility one can obtain radiation bursts of variable duration and intensity. All instru...

  10. Neutron field characterization in the installation for BNCT study in the IEA-R1 reactor; Caracterizacao do campo de neutrons na instalacao para estudo em BNCT no reator IEA-R1

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro Junior, Valdeci

    2008-07-01

    This work aims to characterize the mixed neutron and gamma field, in the sample irradiation position, in a research installation for Boron Neutron Capture Therapy (BNCT), in the IPEN IEA-R1 reactor. The BNCT technique has been studied as a safe and selective option in the treatment of resistant cancerigenous tumors or considered non-curable by the conventional techniques, for example, the Glioblastoma Multiform - a brain cancerigenous tumor. Neutron flux measurements were carried out: thermal, resonance and fast, as well as neutron and gamma rays doses, in the sample position, using activation foils detectors and thermoluminescent dosimeters. For the determination of the neutron spectrum and intensity, a set of different threshold activation foils and gold foils covered and uncovered with cadmium irradiated in the installation was used, analyzed by a high Pure Germanium semiconductor detector, coupled to an electronic system suitable for gamma spectrometry. The results were processed with the SAND-BP code. The doses due to gamma and neutron rays were determined using thermoluminescent dosimeters TLD 400 and TLD 700 sensitive to gamma and TLD 600, sensitive to neutrons. The TLDs were selected and used for obtaining the calibration curves - dosimeter answer versus dose - from each of the TLD three types, which were necessary to calculate the doses due to neutron and gamma, in the sample position. The radiation field, in the sample irradiation position, was characterized flux for thermal neutrons of 1.39.10{sup 8} {+-} 0,12.10{sup 8} n/cm{sup 2}s the doses due to thermal neutrons are three times higher than those due to gamma radiation and confirm the reproducibility and consistency of the experimental findings obtained. Considering these results, the neutron field and gamma radiation showed to be appropriated for research in BNCT. (author)

  11. Latitude Variation of the Subsurface Lunar Temperature: Lunar Prospector Thermal Neutrons

    Science.gov (United States)

    Little, R. C.; Feldman, W. C.; Maurice, S.; Genetay, I.; Lawrence, D. J.; Lawson, S. L.; Gasnault, O.; Barraclough, B. L.; Elphic, R. C.; Prettyman, T. H.; Binder, A. B.

    2001-05-01

    Planetary thermal neutron fluxes provide a sensitive proxy for mafic and feldspathic terranes, and are also necessary for translating measured gamma-ray line strengths to elemental abundances. Both functions require a model for near surface temperatures and a knowledge of the dependence of thermal neutron flux on temperature. We have explored this dependence for a representative sample of lunar soil compositions and surface temperatures using MCNP. For all soil samples, the neutron density is found to be independent of temperature, in accord with neutron moderation theory. The thermal neutron flux, however, does vary with temperature in a way that depends on D, the ratio of macroscopic absorption to energy-loss cross sections of soil compositions. The weakest dependence is for the largest D (which corresponds to the Apollo 17 high Ti basalt in our soil selection), and the largest dependence is for the lowest D (which corresponds to ferroan anorthosite, [FAN] in our selection). For the lunar model simulated, the depth at which the thermal neutron population is most sensitive to temperature is ~30 g/cm**2. These simulations were compared with the flux of thermal neutrons measured using the Lunar Prospector neutron spectrometer over the lunar highlands using a sub-surface temperature profile that varies with latitude, L, as (Cos L)**0.25. The fit is excellent. The best fitting equatorial temperature is determined to be, Teq=224+/-40 K. This temperature range brackets the average temperature measured below the thermal wave at the equator, Tmeas = 252+/-3K [Langseth and Keihm, 1977]. The present result represents the first measurement of subsurface temperature from orbit using neutrons.

  12. Microdosimetry of neutron field for boron neutron capture therapy at Kyoto university reactor.

    Science.gov (United States)

    Endo, S; Onizuka, Y; Ishikawa, M; Takada, M; Sakurai, Y; Kobayashi, T; Tanaka, K; Hoshi, M; Shizuma, K

    2004-01-01

    Microdosimetric single event spectrum in a human body simulated by an acrylic phantom has been measured for the clinical BNCT field at the Kyoto University Reactor (KUR). The recoil particles resulting from the initial reaction and subsequent interactions, namely protons, electrons, alpha particles and carbon nuclei are identified in the microdosimetric spectrum. The relative contributions to the neutron dose from proton, alpha particles and carbon are estimated to be about 0.9, 0.07 and 0.3, respectively, four depths between 5 and 41 mm. We estimate that the dose averaged lineal energy, yD decreased with depth from 64 to 46 keV microm(-1). Relative biological effectiveness (RBE) of this neutron field using a response function for the microdosimetric spectrum was estimated to decrease from 3.6 to 2.9 with increasing depth.

  13. Long distance propagation of a polarized neutron beam in zero magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, U.; Bitter, T.; El-Muzeini, P. (Heidelberg Univ. (Germany). Physikalisches Inst.); Dubbers, D. (Technische Univ. Muenchen, Garching (Germany). Fakultaet fuer Physik E21); Schaerpf, O. (Inst. Laue Langevin, 38 - Grenoble (France))

    1992-09-01

    A beam of fully polarized cold neutrons was transported through a zero magnetic field region of 70 m length without loss of polarization. The purpose of this exercise was twofold: Firstly, to demonstrate that the new zero-field neutron spin-echo method will work also for very long neutron flight paths; secondly, to prove in the most direct way that the neutron free-flight region of the ILL neutron-antineutron oscillation experiment was indeed sufficiently field-free ('quasifree condition') by using the neutrons themselves as a magnetometer. To this purpose the residual magnetic field integrals in the long 'zero-field' region were measured with a conventional neutron spin-echo method. The overall spin precession angle of the neutrons during their flight through the long zero-field region was found to be less than 2[sup 0]. (orig.).

  14. Thermal neutron radiative capture cross-section of 186W(n, γ)187W reaction

    Science.gov (United States)

    Tan, V. H.; Son, P. N.

    2016-06-01

    The thermal neutron radiative capture cross section for 186W(n, γ)187W reaction was measured by the activation method using the filtered neutron beam at the Dalat research reactor. An optimal composition of Si and Bi, in single crystal form, has been used as neutron filters to create the high-purity filtered neutron beam with Cadmium ratio of Rcd = 420 and peak energy En = 0.025 eV. The induced activities in the irradiated samples were measured by a high resolution HPGe digital gamma-ray spectrometer. The present result of cross section has been determined relatively to the reference value of the standard reaction 197Au(n, γ)198Au. The necessary correction factors for gamma-ray true coincidence summing, and thermal neutron self-shielding effects were taken into account in this experiment by Monte Carlo simulations.

  15. The Possibilities of Fission Material Reproduction Increase in Thermal Reactor with the Assemblies with a Hard Neutron Spectrum

    Directory of Open Access Journals (Sweden)

    Vladimir M. Kotov

    2011-01-01

    The possibility of additional neutron source development with the use of fast neutrons with an energy distribution close to the fission spectrum in the major part of thermal reactor core is researched in this paper.

  16. Spectral performance of a composite single-crystal filtered thermal neutron beam for BNCT research at the University of Missouri.

    Science.gov (United States)

    Brockman, J; Nigg, D W; Hawthorne, M F; McKibben, C

    2009-07-01

    Parameter studies, design calculations and initial neutronic performance measurements have been completed for a new thermal neutron beamline to be used for neutron capture therapy cell and small-animal radiobiology studies at the University of Missouri Research Reactor. The beamline features the use of single-crystal silicon and bismuth sections for neutron filtering and for reduction of incident gamma radiation. The calculated and measured thermal neutron fluxes produced at the irradiation location are 9.6 x 10(8) and 8.8 x 10(8)neutrons/cm(2)s, respectively. Calculated and measured cadmium ratios (Au foils) are 217 and 132. These results indicate a well-thermalized neutron spectrum with sufficient thermal neutron flux for a variety of small animal BNCT studies.

  17. Neutron resonance spin echo with longitudinal DC fields

    Science.gov (United States)

    Krautloher, Maximilian; Kindervater, Jonas; Keller, Thomas; Häußler, Wolfgang

    2016-12-01

    We report on the design, construction, and performance of a neutron resonance spin echo (NRSE) instrument employing radio frequency (RF) spin flippers combining RF fields with DC fields, the latter oriented parallel (longitudinal) to the neutron propagation direction (longitudinal NRSE (LNRSE)). The advantage of the longitudinal configuration is the inherent homogeneity of the effective magnetic path integrals. In the center of the RF coils, the sign of the spin precession phase is inverted by a π flip of the neutron spins, such that non-uniform spin precession at the boundaries of the RF flippers is canceled. The residual inhomogeneity can be reduced by Fresnel- or Pythagoras-coils as in the case of conventional spin echo instruments (neutron spin echo (NSE)). Due to the good intrinsic homogeneity of the B0 coils, the current densities required for the correction coils are at least a factor of three less than in conventional NSE. As the precision and the current density of the correction coils are the limiting factors for the resolution of both NSE and LNRSE, the latter has the intrinsic potential to surpass the energy resolution of present NSE instruments. Our prototype LNRSE spectrometer described here was implemented at the resonance spin echo for diverse applications (RESEDA) beamline at the MLZ in Garching, Germany. The DC fields are generated by B0 coils, based on resistive split-pair solenoids with an active shielding for low stray fields along the beam path. One pair of RF flippers at a distance of 2 m generates a field integral of ˜0.5 Tm. The LNRSE technique is a future alternative for high-resolution spectroscopy of quasi-elastic excitations. In addition, it also incorporates the MIEZE technique, which allows to achieve spin echo resolution for spin depolarizing samples and sample environments. Here we present the results of numerical optimization of the coil geometry and first data from the prototype instrument.

  18. LHC RadMon SRAM Detectors Used at Different Voltages to Determine the Thermal Neutron to High Energy Hadron Fluence Ratio

    CERN Document Server

    Kramer, D; Pignard, C; Brugger, M; Spiezia, G; Roeed, K; Klupak, V; Wijnands, T

    2011-01-01

    The thermal neutron SEU cross-section of the Toshiba SRAM memory used in the LHC RadMon system was measured at different voltages. A method using the difference in its response compared to mixed particle energy field is proposed to be used as a discriminator between thermal neutron and high-energy hadron fluences. For test purposes, the proposed method was used at the CNGS and CERF facilities to estimate the field composition by counting SEUs at two different voltages and the results were compared to simulations.

  19. Modification of ROSPEC to cover neutrons from thermal to 18 MeV.

    Science.gov (United States)

    Ing, H; Djeffal, S; Clifford, T; Li, L; Noulty, R; Machrafi, R

    2007-01-01

    Rotating Spectrometer (ROSPEC) is a neutron spectrometer designed to measure neutron energy distributions, and provide accurate neutron dosimetry. It is a completely self-contained unit and measures neutron energy via recoiling protons in gas proportional counters. Each of the four original gas counters is dedicated to a particular neutron energy range dictated by sensitivity to gamma rays at the low energy end of the spectrum and by proton collisions with the counter walls at the high energy end. Introduced originally in 1992, ROSPEC has a proven operational record with a program of continued upgrades. The operating range of the original ROSPEC spans 50 keV-4.5 MeV. The range of the ROSPEC has now been extended down to include epithermal and thermal neutrons by adding two 2 in. (3)He counters. Also, an optional simple scintillation spectrometer was designed to extend the upper limit of ROSPEC up to 18 MeV.

  20. Geant4 Analysis of a Thermal Neutron Real-Time Imaging System

    Science.gov (United States)

    Datta, Arka; Hawari, Ayman I.

    2017-07-01

    Thermal neutron imaging is a technique for nondestructive testing providing complementary information to X-ray imaging for a wide range of applications in science and engineering. Advancement of electronic imaging systems makes it possible to obtain neutron radiographs in real time. This method requires a scintillator to convert neutrons to optical photons and a charge-coupled device (CCD) camera to detect those photons. Alongside, a well collimated beam which reduces geometrical blurriness, the use of a thin scintillator can improve the spatial resolution significantly. A representative scintillator that has been applied widely for thermal neutron imaging is 6LiF:ZnS (Ag). In this paper, a multiphysics simulation approach for designing thermal neutron imaging system is investigated. The Geant4 code is used to investigate the performance of a thermal neutron imaging system starting with a neutron source and including the production of charged particles and optical photons in the scintillator and their transport for image formation in the detector. The simulation geometry includes the neutron beam collimator and sapphire filter. The 6LiF:ZnS (Ag) scintillator is modeled along with a pixelated detector for image recording. The spatial resolution of the system was obtained as the thickness of the scintillator screen was varied between 50 and 400 μm. The results of the simulation were compared to experimental results, including measurements performed using the PULSTAR nuclear reactor imaging beam, showing good agreement. Using the established model, further examination showed that the resolution contribution of the scintillator screen is correlated with its thickness and the range of the neutron absorption reaction products (i.e., the alpha and triton particles). Consequently, thinner screens exhibit improved spatial resolution. However, this will compromise detection efficiency due to the reduced probability of neutron absorption.

  1. Neutron dosimetry; Dosimetria de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Fratin, Luciano

    1993-12-31

    A neutron irradiation facility was designed and built in order to establish a procedure for calibrating neutron monitors and dosemeters. A 185 GBq {sup 241} Am Be source of known is used as a reference source. The irradiation facility using this source in the air provides neutron dose rates between 9 nSv s{sup -1} and 0,5 {sup {mu}}Sv s{sup -1}. A calibrated 50 nSv s{sup -1} thermal neutron field is obtained by using a specially designed paraffin block in conjunction with the {sup 241} Am Be source. A Bonner multisphere spectrometer was calibrated, using a procedure based on three methods proposed by international standards. The unfold {sup 241} Am Be neutron spectrum was determined from the Bonner spheres data and resulted in a good agreement with expected values for fluence rate, dose rate and mean energy. A dosimetric system based on the electrochemical etching of CR-39 was developed for personal dosimetry. The dosemeter badge using a (n,{alpha}) converter, the etching chamber and high frequency power supply were designed and built specially for this project. The electrochemical etching (ECE) parameters used were: a 6N KOH solution, 59 deg C, 20 kV{sub pp} cm{sup -1}, 2,0 kHz, 3 hours of ECE for thermal and intermediate neutrons and 6 hours for fast neutrons. The calibration factors for thermal, intermediate and fast neutrons were determined for this personal dosemeter. The sensitivities determined for the developed dosimetric system were (1,46{+-} 0,09) 10{sup 4} tracks cm{sup -2} mSv{sup -1} for thermal neutrons, (9{+-}3) 10{sup 2} tracks cm{sup -2} mSV{sup -1} for intermediate neutrons and (26{+-}4) tracks cm{sup -2} mSv{sup -1} for fast neutrons. The lower and upper limits of detection were respectively 0,002 mSv and 0,6 mSv for thermal neutrons, 0,04 mSv and 8 mSv for intermediate neutrons and 1 mSv and 12 mSv for fast neutrons. In view of the 1990`s ICRP recommendations, it is possible to conclude that the personal dosemeter described in this work is

  2. The freedom to choose neutron star magnetic field equilibria

    CERN Document Server

    Glampedakis, Kostas

    2016-01-01

    Our ability to interpret and glean useful information from the large body of observations of strongly magnetised neutron stars rests largely on our theoretical understanding of magnetic field equilibria. We answer the following question: is one free to arbitrarily prescribe magnetic equilibria such that fluid degrees of freedom can balance the equilibrium equations? We examine this question for various models for neutron star matter; from the simplest single-fluid barotrope to more realistic non-barotropic multifluid models with superfluid/superconducting components, muons and entropy. We do this for both axi- and non-axisymmetric equilibria, and in Newtonian gravity and general relativity. We show that, in axisymmetry, the most realistic model allows complete freedom in choosing a magnetic field equilibrium whereas non-axisymmetric equilibria are never completely arbitrary.

  3. Accurate characterization of weak neutron fields by using a Bayesian approach.

    Science.gov (United States)

    Medkour Ishak-Boushaki, G; Allab, M

    2017-04-01

    A Bayesian analysis of data derived from neutron spectrometric measurements provides the advantage of determining rigorously integral physical quantities characterizing the neutron field and their respective related uncertainties. The first and essential step in a Bayesian approach is the parameterization of the investigated neutron spectrum. The aim of this paper is to investigate the sensitivity of the Bayesian results, mainly the neutron dose H(*)(10) required for radiation protection purposes and its correlated uncertainty, to the selected neutron spectrum parameterization.

  4. Thermal Effects in Dense Matter Beyond Mean Field Theory

    CERN Document Server

    Constantinou, Constantinos; Prakash, Madappa

    2016-01-01

    The formalism of next-to-leading order Fermi Liquid Theory is employed to calculate the thermal properties of symmetric nuclear and pure neutron matter in a relativistic many-body theory beyond the mean field level which includes two-loop effects. For all thermal variables, the semi-analytical next-to-leading order corrections reproduce results of the exact numerical calculations for entropies per baryon up to 2. This corresponds to excellent agreement down to sub-nuclear densities for temperatures up to $20$ MeV. In addition to providing physical insights, a rapid evaluation of the equation of state in the homogeneous phase of hot and dense matter is achieved through the use of the zero-temperature Landau effective mass function and its derivatives.

  5. Radiative Neutron Capture on Carbon-14 in Effective Field Theory

    CERN Document Server

    Rupak, Gautam; Vaghani, Akshay

    2012-01-01

    The cross section for radiative capture of neutron on carbon-14 is calculated using the model-independent formalism of halo effective field theory. The dominant contribution from E1 transition is considered, and the cross section is expressed in terms of elastic scattering parameters of the effective range expansion. Contributions from both resonant and non-resonant interaction are calculated. Significant interference between these leads to a capture contribution that deviates from simple Breit-Wigner resonance form.

  6. The near-field scanning thermal microscope

    Science.gov (United States)

    Wischnath, Uli F.; Welker, Joachim; Munzel, Marco; Kittel, Achim

    2008-07-01

    We report on the design, characterization, and performance of a near-field scanning thermal microscope capable to detect thermal heat currents mediated by evanescent thermal electromagnetic fields close to the surface of a sample. The instrument operates in ultrahigh vacuum and retains its scanning tunneling microscope functionality, so that its miniature, micropipette-based thermocouple sensor can be positioned with high accuracy. Heat currents on the order of 10-7W are registered in z spectroscopy at distances from the sample ranging from 1 to about 30nm. In addition, the device provides detailed thermographic images of a sample's surface.

  7. Theoretical Study of Compact Objects: Pulsars, Thermally Emitting Neutron Stars and Magnetars

    Science.gov (United States)

    Lai, Dong

    This proposal focuses on understanding the various observational manifestations of magnetized neutron stars (NSs), including pulsars, radio-quiet thermally emitting NSs and magnetars. This is motivated by the recent and ongoing observational progress in the study of isolated NSs, made possible by space telescopes such as Chandra and XMM-Newton, and the prospect of near-future observations by NASA's Gravity and Extreme Magnetism SMEX (GEMS) mission (to be launched in 2014). Recent observations have raised a number of puzzles/questions that beg for theoretical understanding and modeling. The proposed research projects are grouped into two parts: (1) Theoretical modeling of surface (or near surface) X-ray emission from magnetized NSs, including the study of the physics of electron/ion cyclotron lines, radiative transfer during magnetar bursts, dense plasma refractive effect, partially ionized atmospheres, and calculations of X-ray polarization signatures of isolated and accreting magnetic NSs, in anticipation of their detections by GEMS. (2) Theoretical study and observational constraint on the internal structure and evolution of magnetic fields in young neutron stars in supernova remnants. The proposed research will improve our understanding of different populations of NSs and their underlying physical processes (including the extreme physics of strong-field quantum electrodynamics) and enhance the scientific return from the current and future NASA astrophysics missions. It is relevant to NASA's objective, ``Discover the origin, structure, evolution, and destiny of the universe''.

  8. Differentially rotating magnetised neutron stars: production of toroidal magnetic fields

    CERN Document Server

    Thampan, A V

    2004-01-01

    We initiate numerical studies of differentially rotating magnetised (proto) neutron stars by studying - through construction from first principles - the coupling between an assumed differential rotation and an impressed magnetic field. For a perfect incompressible, homogeneous, non-dissipative fluid sphere immersed in an ambient plasma, we solve the (coupled) azimuthal components of the Navier-Stokes equation and the Maxwell induction equation. The assumed time--independent poloidal field lines get dragged by the rotating fluid and produce toroidal magnetic fields. Surface magnetic fields take away energy redistributing the angular momentum to produce rigid rotation along poloidal field lines. Due to absence of viscous dissipation, sustained torsional oscillations are set up within the star. However, the perpetual oscillations of neighbouring `closed' field lines get increasingly out of phase with time, leading to structure build up as in Liu & Shapiro (2004) implying the importance of taking into account...

  9. Neutron star mass-radius relation with gravitational field shielding by a scalar field

    Institute of Scientific and Technical Information of China (English)

    Bo-Jun Zhang; Tian-Xi Zhang; Padmaja Guggilla; Mostafa Dokhanian

    2013-01-01

    The currently well-developed models for equations of state (EoSs) have been severely impacted by recent measurements of neutron stars with a small radius and/or large mass.To explain these measurements,the theory of gravitational field shielding by a scalar field is applied.This theory was recently developed in accordance with the five-dimensional (5D) fully covariant Kaluza-Klein (KK) theory that has successfully unified Einstein's general relativity and Maxwell's electromagnetic theory.It is shown that a massive,compact neutron star can generate a strong scalar field,which can significantly shield or reduce its gravitational field,thus making it more massive and more compact.The mass-radius relation developed under this type of modified gravity can be consistent with these recent measurements of neutron stars.In addition,the effect of gravitational field shielding helps explain why the supernova explosions of some very massive stars (e.g.,40 M⊙ as measured recently) actually formed neutron stars rather than black holes as expected.The EoS models,ruled out by measurements of small radius and/or large mass neutron stars according to the theory of general relativity,can still work well in terms of the 5D fully covariant KK theory with a scalar field.

  10. Fast and thermal neutron intensity measurements at the KFUPM PGNAA setup

    CERN Document Server

    Al-Jarallah, M I; Fazal-Ur-Rehman; Abu-Jarad, F A

    2002-01-01

    Fast and thermal neutron intensity distributions have been measured at an accelerator based prompt gamma ray neutron activation analysis (PGNAA) setup. The setup is built at the 350 keV accelerator laboratory of King Fahd University of Petroleum and Minerals (KFUPM). The setup is mainly designed to carry out PGNAA elemental analysis via thermal neutron capture. In this study relative intensity of fast and thermal neutrons was measured as a function of the PGNAA moderator assembly parameters using nuclear track detectors (NTDs). The relative intensity of the neutrons was measured inside the sample region as a function of front moderator thickness as well as sample length. Measurements were carried out at the KFUPM 350 keV accelerator using 2.8 MeV pulsed neutron beam from D(d,n) reaction. The pulsed deuteron beam with 5 ns pulse width and 30 kHz frequency was used to produce neutrons. Experimental results were compared with results of Monte Carlo design calculations of the PGNAA setup. A good agreement has bee...

  11. INFLUENCE OF SCATTERED NEUTRON RADIATION ON METROLOGICAL CHARACTERISTICS OF АТ140 NEUTRON CALIBRATION FACILITY

    Directory of Open Access Journals (Sweden)

    D. I. Komar

    2017-01-01

    Full Text Available Today facilities with collimated radiation field are widely used as reference in metrological support of devices for neutron radiation measurement. Neutron fields formed by radionuclide neutron sources. The aim of this research was to study characteristics of experimentally realized neutron fields geometries on АТ140 Neutron Calibration Facility using Monte Carlo method.For calibration, we put a device into neutron field with known flux density or ambient equivalent dose rate. We can form neutron beam from radionuclide fast-neutron source in different geometries. In containercollimator of АТ140 Neutron Calibration Facility we can install special inserts to gather fast-neutron geometry or thermal-neutron geometry. We need to consider neutron scattering from air and room’s walls. We can conduct measurements of neutron field characteristics in several points and get the other using Monte Carlo method.Thermal neutron collimator forms a beam from radionuclide source with a significant amount of neutrons with thermal energies. From found relationship between full neutron flux and distance to neutron source we see that inverse square law is violated. Scattered radiation contribution into total flux increases when we are moving away from neutron source and significantly influences neutron fields characteristics. While source is exposed in shadow-cone geometry neutron specter has pronounced thermal component from wall scattering.In this work, we examined main geometry types used to acquire reference neutron radiation using radionuclide sources. We developed Monte Carlo model for 238Pu-Be neutron source and АТ140 Neutron Calibration Facility’s container-collimator. We have shown the most significant neutron energy distribution factor to be scattered radiation from room’s walls. It leads to significant changes of neutron radiation specter at a distance from the source. When planning location, and installing the facility we should consider

  12. A new monitor for routine thermal and epithermal neutron fluence rate monitoring in k0 INAA.

    Science.gov (United States)

    Koster-Ammerlaan, M J J; Bacchi, M A; Bode, P; De Nadai Fernandes, E A

    2008-12-01

    The Zr-Au set for monitoring the thermal and epithermal neutron fluence rate and the epithermal spectrum parameter alpha is not always practicable for routine application of INAA in well-thermalized facilities. An alternative set consisting of Cr, Au and Mo provides values for the thermal neutron fluence rate, f and alpha that are not significantly different from those found via the Zr-Au method and the Cd-covered Zr-method. The IRMM standard SMELS-II was analyzed using the (Au-Cr-Mo) monitor and a good agreement was obtained.

  13. Characterization of Monoenergetic Low Energy Neutron Fields with the {mu}TPC Detector

    Energy Technology Data Exchange (ETDEWEB)

    Golabek, C.; Lebreton, L.; Petit, M. [Laboratoire de Metrologie et de Dosimetrie des Neutrons, IRSN Cadarache, 13115 Saint-Paul-Lez-Durance (France); Billard, J.; Grignon, C.; Bosson, G.; Bourrion, O.; Guillaudin, O.; Mayet, F.; Richer, J.-P.; Santos, D. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Joseph (France)

    2011-12-13

    The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 2 keV up to 1 MeV. We present simulations showing that such a detector, which allows the measurement of the ionization energy and the 3D reconstruction of the recoil nucleus, provides the determination of neutron energy and fluence of such low energy neutron fields.

  14. Preliminary Research of Neutron Energy Spectrum of Thermal Neutron Beam Port for IHNI

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    IHNI with 30 kW is specially designed for Boron Neutron Capture Therapy (BNCT), it is the pool-tank reactor, UO2 with enrichment of 12.5% 235U as fuel, beryllium as reflector, light water as moderator and coolant. There are two neutron beams in the opposite side

  15. Neutron oscillations in a periodically varying magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Pusch, G.D. (Virginia Polytechnic Inst. and State Univ., Blacksburg (USA). Dept. of Physics)

    1983-03-21

    We transform the driven-neutron-oscillation problem into a form similar to a magnetic-resonance problem in an internal space, and obtain an approximate analytical solution in the neighborhood of the resonances. The results are in good agreement with the numerical work of Arndt, Prasad and Riazuddin. We find that the anti n probability is quite insensitive to variations in magnetic-field strength and driving frequency when near a resonance maximum, the only critical aspect being the alginment between the static and oscillating fields.

  16. Signatures of photon-axion conversion in the thermal spectra and polarization of neutron stars

    CERN Document Server

    Perna, Rosalba; Verde, Licia; van Adelsberg, Matthew; Jimenez, Raul

    2012-01-01

    Conversion of photons into axions under the presence of a strong magnetic field can dim the radiation from magnetized astrophysical objects. Here we perform a detailed calculation aimed at quantifying the signatures of photon-axion conversion in the spectra, light curves, and polarization of neutron stars (NSs). We take into account the energy and angle-dependence of the conversion probability and the surface thermal emission from NSs. The latter is computed from magnetized atmosphere models that include the effect of photon polarization mode conversion due to vacuum polarization. The resulting spectral models, inclusive of the general-relativistic effects of gravitational redshift and light deflection, allow us to make realistic predictions for the effects of photon to axion conversion on observed NS spectra, light curves, and polarization signals. We identify unique signatures of the conversion, such as an increase of the effective area of a hot spot as it rotates away from the observer line of sight. For a...

  17. Investigation of the response characteristics of OSL albedo neutron dosimeters in a 241AmBe reference neutron field

    Science.gov (United States)

    Liamsuwan, T.; Wonglee, S.; Channuie, J.; Esoa, J.; Monthonwattana, S.

    2017-06-01

    The objective of this work was to systematically investigate the response characteristics of optically stimulated luminescence Albedo neutron (OSLN) dosimeters to ensure reliable personal dosimetry service provided by Thailand Institute of Nuclear Technology (TINT). Several batches of InLight® OSLN dosimeters were irradiated in a reference neutron field generated by the in-house 241AmBe neutron irradiator. The OSL signals were typically measured 24 hours after irradiation using the InLight® Auto 200 Reader. Based on known values of delivered neutron dose equivalent, the reading correction factor to be used by the reader was evaluated. Subsequently, batch homogeneity, dose linearity, lower limit of detection and fading of the OSLN dosimeters were examined. Batch homogeneity was evaluated to be 0.12 ± 0.05. The neutron dose response exhibited a linear relationship (R2=0.9974) within the detectable neutron dose equivalent range under test (0.4-3 mSv). For this neutron field, the lower limit of detection was between 0.2 and 0.4 mSv. Over different post-irradiation storage times of up to 180 days, the readings fluctuated within ±5%. Personal dosimetry based on the investigated OSLN dosimeter is considered to be reliable under similar neutron exposure conditions, i.e. similar neutron energy spectra and dose equivalent values.

  18. Properties of Neutron Stars Rotating at Kepler Frequency with Uniform Strong Magnetic Field

    Institute of Scientific and Technical Information of China (English)

    WEN De-Hua; CHEN Wei; LU Yi-Gang; LIU Liang-Gang

    2007-01-01

    A uniform strong magnetic field is considered in calculating the properties of neutron star rotating at the Kepler frequency. The results show that the effect of the magnetic field on the properties of neutron star is evident, and the properties of the neutron stars rotating at the Kepler frequency can be used as a criterion to the equations of states of the neutron star matters.

  19. LUPIN, a new instrument for pulsed neutron fields

    Science.gov (United States)

    Caresana, M.; Ferrarini, M.; Manessi, G. P.; Silari, M.; Varoli, V.

    2013-06-01

    A number of studies focused in the last decades on the development of survey meters to be used in pulsed radiation fields. This is a topic attracting widespread interest for applications such as radiation protection and beam diagnostics in accelerators. This paper describes a new instrument specifically conceived for applications in pulsed neutron fields (PNF). The detector, called LUPIN, is a rem counter type instrument consisting of a 3He proportional counter placed inside a spherical moderator. It works in current mode with a front-end electronics consisting of a current-voltage logarithmic amplifier, whose output signal is acquired with an ADC and processed on a PC. This alternative signal processing allows the instrument to be used in PNF without being affected by saturation effects. Moreover, it has a measurement capability ranging over many orders of burst intensity. Despite the fact that it works in current mode, it can measure a single neutron interaction. The LUPIN was first calibrated in CERN's calibration laboratory with a PuBe source. Measurements were carried out under various experimental conditions at the Helmholtz-Zentrum in Berlin, in the stray field at various locations of the CERN Proton Synchrotron complex and around a radiotherapy linear accelerator at the S. Raffaele hospital in Milan. The detector can withstand single bursts with values of H*(10) up to 16 nSv/burst without showing any saturation effect. It efficiently works in pulsed stray fields, where a conventional rem-counter underestimates by a factor of 2. It is also able to reject the very intense and pulsed photon contribution that often accompanies the neutron field with good reliability.

  20. Impact of the neutron and nuclear matter equations of state on neutron skin and neutron drip lines in chiral effective field theory

    CERN Document Server

    Sammarruca, Francesca

    2016-01-01

    We present predictions of the binding energy per nucleon and the neutron skin thickness in highly neutron-rich isotopes of Oxygen, Magnesium, and Aluminum. The calculations are carried out at and below the neutron drip line. The nuclear properties are obtained via an energy functional whose input is the equation of state of isospin-asymmetric in?finite matter. The latter is based on a microscopic derivation applying chiral few-nucleon forces. We highlight the impact of the equation of state at diff?erent orders of chiral effective fi?eld theory and discuss the role of three-neutron forces.

  1. Electromagnetic field occupational exposure: non-thermal vs. thermal effects.

    Science.gov (United States)

    Israel, M; Zaryabova, V; Ivanova, M

    2013-06-01

    There are a variety of definitions for "non-thermal effects" included in different international standards. They start by the simple description that they are "effects of electromagnetic energy on a body that are not heat-related effects", passing through the very general definition related to low-level effects: "biological effects ascribed to exposure to low-level electric, magnetic and electromagnetic fields, i.e. at or below the corresponding dosimetric reference levels in the frequency range covered in this standard (0 Hz-300 GHz)", and going to the concrete definition of "the stimulation of muscles, nerves, or sensory organs, vertigo or phosfenes". Here, we discuss what kind of effect does the non-thermal one has on human body and give data of measurements in different occupations with low-frequency sources of electromagnetic field such as electric power distribution systems, transformers, MRI systems and : video display units (VDUs), whereas thermal effects should not be expected. In some of these workplaces, values above the exposure limits could be found, nevertheless that they are in the term "non-thermal effects" on human body. Examples are workplaces in MRI, also in some power plants. Here, we will not comment on non-thermal effects as a result of RF or microwave exposure because there are not proven evidence about the existance of such effects and mechanisms for them are not clear.

  2. Numerical Simulations of Pillar Structured Solid State Thermal Neutron Detector Efficiency and Gamma Discrimination

    Energy Technology Data Exchange (ETDEWEB)

    Conway, A; Wang, T; Deo, N; Cheung, C; Nikolic, R

    2008-06-24

    This work reports numerical simulations of a novel three-dimensionally integrated, {sup 10}boron ({sup 10}B) and silicon p+, intrinsic, n+ (PIN) diode micropillar array for thermal neutron detection. The inter-digitated device structure has a high probability of interaction between the Si PIN pillars and the charged particles (alpha and {sup 7}Li) created from the neutron - {sup 10}B reaction. In this work, the effect of both the 3-D geometry (including pillar diameter, separation and height) and energy loss mechanisms are investigated via simulations to predict the neutron detection efficiency and gamma discrimination of this structure. The simulation results are demonstrated to compare well with the measurement results. This indicates that upon scaling the pillar height, a high efficiency thermal neutron detector is possible.

  3. Simulation and optimisation of a position sensitive scintillation detector with wavelength shifting fibers for thermal neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Herzkamp, Matthias; Engels, Ralf; Kemmerling, Guenter [ZEA-2, Forschungszentrum Juelich (Germany); Brueckel, Thomas [JCNS, Forschungszentrum Juelich (Germany); Stahl, Achim [III. Physikalisches Institut B, RWTH Aachen (Germany); Waasen, Stefan van [ZEA-2, Forschungszentrum Juelich (Germany); Faculty of Engineering, University of Duisburg-Essen (Germany)

    2015-07-01

    In neutron scattering experiments it is important to have position sensitive large scale detectors for thermal neutrons. A detector based on a neutron scintillator with wave length shifting fibers is a new kind of such a detector. We present the simulation of the detector based on the microscopic structure of the scintillation material of the mentioned detector. It consists of a converter and a scintillation powder bound in a matrix. The converter in our case is lithium fluoride with enriched lithium 6, to convert thermal neutrons into high energetic alpha and triton particles. The scintillation material is silver doped zinc sulfide. We show that pulse height spectra obtained by these scintillators can be be explained by the simple model of randomly distributed spheres of zinc sulfide and lithium fluoride. With this model, it is possible to optimise the mass ratio of zinc sulfide to lithium fluoride with respect to detection efficiency and/or energy deposition in zinc sulfide.

  4. Enhancement of thermal neutron shielding of cement mortar by using borosilicate glass powder.

    Science.gov (United States)

    Jang, Bo-Kil; Lee, Jun-Cheol; Kim, Ji-Hyun; Chung, Chul-Woo

    2017-05-01

    Concrete has been used as a traditional biological shielding material. High hydrogen content in concrete also effectively attenuates high-energy fast neutrons. However, concrete does not have strong protection against thermal neutrons because of the lack of boron compound. In this research, boron was added in the form of borosilicate glass powder to increase the neutron shielding property of cement mortar. Borosilicate glass powder was chosen in order to have beneficial pozzolanic activity and to avoid deleterious expansion caused by an alkali-silica reaction. According to the experimental results, borosilicate glass powder with an average particle size of 13µm showed pozzolanic activity. The replacement of borosilicate glass powder with cement caused a slight increase in the 28-day compressive strength. However, the incorporation of borosilicate glass powder resulted in higher thermal neutron shielding capability. Thus, borosilicate glass powder can be used as a good mineral additive for various radiation shielding purposes.

  5. A novel method to measure low flux ambient thermal neutrons with 3He proportional counters

    Science.gov (United States)

    Zeng, Z. M.; Gong, H.; Yue, Q.; Li, J. M.

    2017-09-01

    A pulse shape discrimination method to discriminate neutron events from backgrounds based on the double-pulse effect of 3He proportional counters is proposed and detailed in this paper. We made an ambient thermal neutron measurement system composed of a commercial 3He proportional counter tube and the corresponding readout electronics. The background of the system has been measured and the minimum detectable amount of the 3He proportional counter tube will be reduced by an order of magnitude with this method. The system was applied to measure the ambient thermal neutron flux inside a large neutron shielding structure at a deep underground laboratory and the pulse shape discrimination method proves to be effective.

  6. TPC-like readout for thermal neutron detection using a GEM-detector

    CERN Document Server

    Flierl, Bernhard; Hertenberger, Ralf; Zeitelhack, Karl

    2015-01-01

    Spatial resolution of less than 200 um is challenging for thermal neutron detection. A novel readout scheme based on the time-projection-chamber (TPC) concept is used in a gaseous electron multiplier (GEM) detector. Thermal neutrons are captured in a single 2 um thick Boron-10 converter cathode and secondary Helium and Lithium ions are produced with a combined energy of 2.8 MeV. These ions have sufficient energy to form straight tracks of several mm length. With a time resolving 2-dimensional readout of 400 um pitch in both directions, based on APV25 chips, the ions are tracked and their respective origin in the cathode converter foil is reconstructed. Using an Ar-CO2 93:7% gas mixture, a resolution of 100 um (FWHM 235 um) has been observed with a triple GEM-detector setup at the Garching neutron source (FRMII) for neutrons of 4.7 Angstrom.

  7. Underground physics and the barometric pumping effect observed for thermal neutron flux underground

    Science.gov (United States)

    Stenkin, Yu. V.; Alekseenko, V. V.; Gromushkin, D. M.; Sulakov, V. P.; Shchegolev, O. B.

    2017-05-01

    It is known that neutron background is a major problem for low-background experiments carrying out underground, such as dark matter search, double-beta decay searches and other experiments known as Underground Physics. We present here some results obtained with the en-detector of 0.75 m2, which is running for more than 4 years underground at a depth of 25 m water equivalent in Skobeltsyn Institute of Nuclear Physics, Moscow State University. Some spontaneous increases in thermal neutron flux up to a factor of 3 were observed in delayed anti-correlation with barometric pressure. The phenomenon can be explained by the radon barometric pumping effect resulting in similar effect in neutron flux being produced in (α, n)-reactions by alpha-decays of radon and its daughters in surrounding rock. This is the first demonstration of the barometric pumping effect observed in thermal neutron flux underground.

  8. Analyzing Neutron Star in HESS J1731-347 from Thermal Emission and Cooling Theory

    CERN Document Server

    Ofengeim, D D; Klochkov, D; Suleimanov, V; Yakovlev, D G

    2015-01-01

    The central compact object in the supernova remnant HESS J1731-347 appears to be the hottest observed isolated cooling neutron star. The cooling theory of neutron stars enables one to explain observations of this star by assuming the presence of strong proton superfluidity in the stellar core and the existence of the surface heat blanketing envelope which almost fully consists of carbon. The cooling model of this star is elaborated to take proper account of the neutrino emission due to neutron-neutron collisions which is not suppressed by proton superfluidity. Using the results of spectral fits of observed thermal spectra for the distance of 3.2 kpc and the cooling theory for the neutron star of age 27 kyr, new constraints on the stellar mass and radius are obtained which are more stringent than those derived from the spectral fits alone.

  9. Monte Carlo simulation of a very high resolution thermal neutron detector composed of glass scintillator microfibers

    CERN Document Server

    Yushou, Song; Zhang, Xiaodong; Hayward, Jason P

    2016-01-01

    In order to develop a high spatial resolution (micron level) thermal neutron detector, a detector assembly composed of cerium doped lithium glass microfibers, each with a diameter of 1\\,$\\mu$m, is proposed, where the neutron absorption location is reconstructed from the observed charged particle products that result from neutron absorption. To suppress the cross talk of the scintillation light, each scintillating fiber is surrounded by air-filled glass capillaries with the same diameter as the fiber. This pattern is repeated to form a bulk microfiber detector. On one end, the surface of the detector is painted with a thin optical reflector to increase the light collection efficiency at the other end. Then the scintillation light emitted by any neutron interaction is transmitted to one end, magnified, and recorded by an intensified CCD camera. A simulation based on the Geant4 toolkit was developed to model this detector. All the relevant physics processes including neutron interaction, scintillation, and optic...

  10. Image processing analysis of nuclear track parameters for CR-39 detector irradiated by thermal neutron

    Science.gov (United States)

    Al-Jobouri, Hussain A.; Rajab, Mustafa Y.

    2016-03-01

    CR-39 detector which covered with boric acid (H3Bo3) pellet was irradiated by thermal neutrons from (241Am - 9Be) source with activity 12Ci and neutron flux 105 n. cm-2. s-1. The irradiation times -TD for detector were 4h, 8h, 16h and 24h. Chemical etching solution for detector was sodium hydroxide NaOH, 6.25N with 45 min etching time and 60 C˚ temperature. Images of CR-39 detector after chemical etching were taken from digital camera which connected from optical microscope. MATLAB software version 7.0 was used to image processing. The outputs of image processing of MATLAB software were analyzed and found the following relationships: (a) The irradiation time -TD has behavior linear relationships with following nuclear track parameters: i) total track number - NT ii) maximum track number - MRD (relative to track diameter - DT) at response region range 2.5 µm to 4 µm iii) maximum track number - MD (without depending on track diameter - DT). (b) The irradiation time -TD has behavior logarithmic relationship with maximum track number - MA (without depending on track area - AT). The image processing technique principally track diameter - DT can be take into account to classification of α-particle emitters, In addition to the contribution of these technique in preparation of nano- filters and nano-membrane in nanotechnology fields.

  11. Physical Processes in Strong Magnetic Fields of Neutron Stars

    CERN Document Server

    Harding, A K

    2003-01-01

    Neutron stars have inferred surface magnetic fields of up to 10^{14} Gauss, in the case of radio pulsars, and up to possibly 10^{15} Gauss, in the case of Soft Gamma-Ray Repeaters and Anomalous X-ray Pulsars. In fields this high, QED effects will profoundly change the characteristics of continuum radiation processes such as synchrotron emission and Compton scattering and will also allow the possibility of additional physical processes such as one-photon pair production, vacuum polarization and photon splitting. Atomic line processes will also be significantly affected by the presence of strong fields. I will review some of the properties of radiation processes in strong magnetic fields that are most relevant to pulsars, SGRs and AXPs and the role they play in models for these sources.

  12. Feasibility study of fast neutron energy spectrometer using magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Yamagishi, Hideshi; Ara, Katsuyuki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-09-01

    A feasibility study of a fast neutron energy spectrometer (NES) using magnetic field was performed for development of a spectrometer having a measuring range of 3 decades and a covered energy range of 8 decades. The NES that is a kind of proton recoil spectrometer consists of a proton radiator, a magnet and a screen to detect protons. The pass of each charge particle flying into the magnetic field is deflected with a certain angle depending on the velocity of the particle, and it reaches the screen of charged particle detection after passing through the magnetic field. The energy of the particle is measured from the position on the screen at which the particle collide with. In this paper, optimization of the magnet geometry and the magnetic field intensity of the NES are discussed. The NES that is designed with the optimized geometry provides the measuring range of 3 decades with an energy measuring error of less than {+-}9%. A neutron energy range of 9 decades from 0.1 (eV) to 100 (MeV) is covered by adjusting the magnetic flux density. (author)

  13. Recent developments and applications for the University of Texas Thermal Neutron Imaging Facility.

    Science.gov (United States)

    Dorsey, D J; Charlton, W S

    2004-10-01

    The Thermal Neutron Imaging Facility (UT-TNIF) at the University of Texas at Austin is being modified to begin work with the non-destructive evaluation of carbon fiber composite materials intended for use in space. The use of high-resolution borated micro channel plate (MCP) detectors has been investigated. MCNP calculations to redesign the external radiation shielding to allow UT-TNIF operation at higher reactor powers and to minimize internal neutron scattering have been performed.

  14. Optimizing diode thickness for thin-film solid state thermal neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, John W.; Mejia, Israel; Quevedo-Lopez, Manuel A.; Gnade, Bruce [Department of Materials and Science, University of Texas at Dallas, Richardson, Texas 75080 (United States); Kunnen, George R.; Allee, David [Flexible Display Center at Arizona State University, Tempe, Arizona 85284 (United States)

    2012-10-01

    In this work, we investigate the optimal thickness of a semiconductor diode for thin-film solid state thermal neutron detectors. We evaluate several diode materials, Si, CdTe, GaAs, C (diamond), and ZnO, and two neutron converter materials, {sup 10}B and {sup 6}LiF. Investigating a coplanar diode/converter geometry, we determine the minimum semiconductor thickness needed to achieve maximum neutron detection efficiency. By keeping the semiconductor thickness to a minimum, gamma rejection is kept as high as possible. In this way, we optimize detector performance for different thin-film semiconductor materials.

  15. Surface temperature of a magnetized neutron star and interpretation of the ROSAT data. 1: Dipole fields

    Science.gov (United States)

    Page, Dany

    1995-01-01

    We model the temperature distribution at the surface of a magnetized neutron star and study the effects on the observed X-ray spectra and light curves. Generalrelativistic effects, i.e., redshift and lensing, are fully taken into account. Atmospheric effects on the emitted spectral flux are not included: we consider only blackbody emission at the local effective temperature. In this first paper we restrict ourselves to dipole fields. General features are studied and compared with the ROSAT data from the pulsars 0833 - 45 (Vela), 0656 + 14, 0630 + 178 (Geminga), and 1055 - 52, the four cases for which there is strong evidence that thermal radiation from the stellar surface is detected. The composite spectra we obtain are not very different from a blackbody spectrum at the star's effective temperature. We conclude that, as far as blackbody spectra are considered, temperature estimates using single-temperature models give results practically identical to our composite models. The change of the (composite blackbody) spectrum with the star's rotational phase is also not very large and may be unobservable inmost cases. Gravitational lensing strongly suppresses the light curve pulsations. If a dipole field is assumed, pulsed fractions comparable to the observed ones can be obtained only with stellar radii larger than those which are predicted by current models of neutron star struture, or with low stellar masses. Moreover, the shapes of the theoretical light curves with dipole fields do not correspond to the observations. The use of magnetic spectra may raise the pulsed fraction sufficiently but will certainly make the discrepancy with the light curve shapes worse: dipole fields are not sufficient to interpret the data. Many neutron star models with a meson condensate or hypersons predict very small radii, and hence very strong lensing, which will require highly nondipolar fields to be able to reproduce the observed pulsed fractions, if possible at all: this may be a new

  16. Thermal neutron cross-section libraries for aromatic hydrocarbons

    Science.gov (United States)

    Cantargi, F.; Granada, J. R.

    2010-08-01

    Solid phases of aromatic hydrocarbons, such as benzene, toluene, mesitylene and a 3:2 mixture by volume of mesitylene and toluene, were studied as potential moderator materials for a cold neutron source. Existing information on the (lattice) translational and rotational modes of the different molecular species was used to produce generalized frequency spectra; the latter included the internal vibrational modes which in turn involved the analysis of the weights of the different modes. Cross-section libraries were generated in ENDF and ACE formats for hydrogen bounded in those materials at several temperatures, and were used in Monte Carlo calculations to analyze their neutron production compared with standard cryogenic materials like liquid hydrogen and solid methane, the best moderators in terms of cold neutron production. In particular, cross-section libraries were generated at 20 K, which is a typical operating temperature for the majority of the existing cold neutron sources. It was found that those aromatic hydrocarbons produce neutron spectra which are slightly warmer than that of solid methane while presenting a high resistance to radiation, conforming in this way a new and advantageous alternative to traditional moderator materials.

  17. Scatter rejection in quantitative thermal and cold neutron imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tremsin, A.S., E-mail: ast@ssl.berkeley.edu [Space Sciences Laboratory, University of California at Berkeley, Berkeley, CA 94720 (United States); Kardjilov, N; Dawson, M; Strobl, M.; Manke, I. [Helmholtz-Zentrum Berlin, 14109 Berlin (Germany); McPhate, J.B.; Vallerga, J.V.; Siegmund, O.H.W. [Space Sciences Laboratory, University of California at Berkeley, Berkeley, CA 94720 (United States); Feller, W.B. [Nova Scientific, Inc., 10 Picker Road, Sturbridge, MA 01566 (United States)

    2011-09-21

    The accuracy of quantitative neutron transmission radiography can be substantially decreased if highly scattering materials, such as water or plastics, exist in the sample. There are currently two main solutions to this problem: either performing experiments at a large distance between the detector and the sample or employ some numerical correction techniques. In the former case, the spatial resolution is substantially reduced by the limited beam divergence, while the latter correction requires a priori information about the sample and is limited to distances of above {approx}2 cm. We demonstrate the feasibility of another technique, namely the possibility to remove the scattered neutron component from the transmitted neutron beam by a very compact polycapillary collimator. These {approx}1 mm thick devices can be placed between the sample and the detector and remove most of the neutrons scattered at angles larger than the acceptance angle of the collimator (typically 1{sup o}). No image distortions above {approx}10 {mu}m scales are introduced by these collimators. The neutron transmission of highly scattering samples (water and plexiglass) is measured in our experiments with and without scatter rejection. In the latter case, the accuracy of measured transmission coefficient was substantially improved by our collimators.

  18. Neutronic and thermal-hydraulic analysis of new irradiation channels inside the Moroccan TRIGA Mark II research reactor core.

    Science.gov (United States)

    Chham, E; El Bardouni, T; Benaalilou, K; Boukhal, H; El Bakkari, B; Boulaich, Y; El Younoussi, C; Nacir, B

    2016-10-01

    This study was conducted to improve the capacity of radioisotope production in the Moroccan TRIGA Mark II research reactor, which is considered as one of the most important applications of research reactors. The aim of this study is to enhance the utilization of TRIGA core in the field of neutron activation and ensure an economic use of the fuel. The main idea was to create an additional irradiation channel (IC) inside the core. For this purpose, three new core configurations are proposed, which differ according to the IC position in the core. Thermal neutron flux distribution and other neutronic safety parameters such as power peaking factors, excess reactivity, and control rods worth reactivity were calculated using the Monte Carlo N-Particle Transport (MCNP) code and neutron cross-section library based on ENDF/B-VII evaluation. The calculated thermal flux in the central thimble (CT) and in the added IC for the reconfigured core is compared with the thermal flux in the CT of the existing core, which is taken as a reference. The results show that all the obtained fluxes in CTs are very close to the reference value, while a remarkable difference is observed between the fluxes in the new ICs and reference. This difference depends on the position of IC in the reactor core. To demonstrate that the Moroccan TRIGA reactor could safely operate at 2MW, with new configurations based on new ICs, different safety-related thermal-hydraulic parameters were investigated. The PARET model was used in this study to verify whether the safety margins are met despite the new modifications of the core. The results show that it is possible to introduce new ICs safely in the reactor core, because the obtained values of the parameters are largely far from compromising the safety of the reactor.

  19. Thermal neutron flux measurement using the DUPIC SPND-instrumented rig

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C. Y.; Moon, J. S.; Park, H. S.; Kang, K. H.; Ryu, H. J.; Jeong, I. H.; Song, K. C.; Yang, M. S. [KAERI, Taejon (Korea, Republic of)

    2002-05-01

    The 3rd irradiation test of DUPIC fuel, which was fabricated in the DFDF(DUPIC Fuel Development Facility) was performed in HANARO. For the objectives of this irradiation test, the newly designed irradiation rig was equipped with three Rh- type SPND sensors around DUPIC mini-elements for estimating the thermal neutron flux in the OR4 hole. The thermal neutron flux was measured at this location for 5 months the start of the test. The measured data were transmitted to monitoring system. We confirmed that the trend of SPND signal is well agree with that of HANARO power. The measured average thermal neutron flux is 0.45 n/cm{sup 2} {center_dot}s and the average linear power of DUPIC mini-element was estimated to be 33.5 KW/m.

  20. The measurements of thermal neutron flux distribution in a paraffin phantom

    Indian Academy of Sciences (India)

    Parisa Akhlaghi; Laleh Rafat-Motavalli; Seyed Hashem Miri-Hakimabad

    2013-05-01

    The term `thermal flux' implies a Maxwellian distribution of velocity and energy corresponding to the most probable velocity of 2200 ms-1 at 293.4 K. In order to measure the thermal neutron flux density, the foil activation method was used. Thermal neutron flux determination in paraffin phantom by counting the emitted rays of indium foils with two different detectors (Geiger–Muller counter and NaI(Tl)) was the aim of this project. The relative differences of the outcome of the experiments were between 2.5% and 5%. The final results were compared with MCNP4C outputs and the best agreement was generated using NaI(Tl) by a minimum discrepancy of about 0.6% for the foil placed 8.5 cm from the neutron source.

  1. Measured Thermal and Fast Neutron Fluence Rates for ATF-1 Holders During ATR Cycle 157D

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Larry Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, David Torbet [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-03-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 157D which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution.

  2. Gamma neutron method applied to field measurement of hydrodynamic dispersion

    Science.gov (United States)

    Brissaud, F.; Pappalardo, A.; Couchat, Ph.

    1983-06-01

    The gamma neutron method is applied to the study of solute movements during field irrigations under steady-state and transient hydrodynamic conditions. Two different types of behavior are discussed. In the first, the labeled water pulse velocity matches the conservation of the vertical rate of water and, when the deuterated water concentration profiles are mass-conservative, the experimental results are accurately described by the equation of dispersion. In the second, the pore water velocity differs considerably from that of strictly vertical displacements and the concentration profiles are not massconservative.

  3. On accelerator-based neutron sources and neutron field characterization with low energy neutron spectrometer based on position sensitive 3He counter.

    Science.gov (United States)

    Murata, I; Miyamaru, H; Kato, I; Mori, Y

    2009-07-01

    The development of new neutron sources for BNCT applications, based on particle accelerators is currently underway all over the world. Though nuclear reactors were used for a long time as the only neutron source available having the requested flux levels, the accelerator-based ones have recently been investigated on the other hand due to its easy-to-use and acceptable performances. However, when using an accelerator, various secondary particles would be emitted which forms a troublesome background. Moreover, the neutrons produced have usually an energy spectrum somewhat different from the requested one and thus should be largely moderated. An additional issue to be taken into account is the patient positioning, which should be close to the neutron source, in order to take advantage of a neutron flux level high enough to limit the BNCT treatment time within 1h. This implies that, inside a relatively narrow space, neutrons should be moderated, while unnecessary secondary particles should be shielded. Considering that a background-free neutron field from an accelerator-driven neutron source dedicated to BNCT application is generally difficult to be provided, the characterization of such a neutron field will have to be clearly assessed. In the present study, a low energy neutron spectrometer has been thus designed and is now being developed to measure the accelerator-based neutron source performance. The presently proposed spectrometer is based on a (3)He proportional counter, which is 50 cm long and 5 cm in diameter, with a gas pressure of 0.5 MPa. It is quite unique that the spectrometer is set up in parallel with the incident neutron beam and a reaction depth distribution is measured by it as a position sensitive detector. Recently, a prototype detector has been developed and the signal test is now underway. In this paper, the feature of the accelerator-based neutron sources is outlined and importance of neutron field characterization is discussed. And the developed

  4. Comparison of Thermal Neutron Detection Efficiency of $^{6}$Li Scintillation Glass and $^{3}$He Gas Proportional Tube

    CERN Document Server

    Xu, Ming; Chen, Guo-Ming; Tao, Jun-Quan

    2013-01-01

    We report on a comparison study of the $^{3}$He gas proportional tube and the $^{6}$Li incorporated scintillation glasses on thermal neutron detection efficiency. Both $^{3}$He and $^{6}$Li are used commonly for thermal neutron detection because of their high neutron capture absorption coefficient. By using a neutron source $^{252}$Cf and a paraffin moderator in an alignment system, we can get a small beam of thermal neutrons. A flash ADC is used to measure the thermal neutron spectrum of each detector, and the detected number of events is determined from the spectrum, then we can calculate the detection efficiency of different detectors. Meanwhile, the experiment have been modeled with GEANT4 to validate the results against the Monte Carlo simulation.

  5. Thermal neutron capture and resonance integral cross sections of 45Sc

    Science.gov (United States)

    Van Do, Nguyen; Duc Khue, Pham; Tien Thanh, Kim; Thi Hien, Nguyen; Kim, Guinyun; Kim, Kwangsoo; Shin, Sung-Gyun; Cho, Moo-Hyun; Lee, Manwoo

    2015-11-01

    The thermal neutron cross section (σ0) and resonance integral (I0) of the 45Sc(n,γ)46Sc reaction have been measured relative to that of the 197Au(n,γ)198Au reaction by means of the activation method. High-purity natural scandium and gold foils without and with a cadmium cover of 0.5 mm thickness were irradiated with moderated pulsed neutrons produced from the Pohang Neutron Facility (PNF). The induced activities in the activated foils were measured with a high purity germanium (HPGe) detector. In order to improve the accuracy of the experimental results the counting losses caused by the thermal (Gth) and resonance (Gepi) neutron self-shielding, the γ-ray attenuation (Fg) and the true γ-ray coincidence summing effects were made. In addition, the effect of non-ideal epithermal spectrum was also taken into account by determining the neutron spectrum shape factor (α). The thermal neutron cross-section and resonance integral of the 45Sc(n,γ)46Sc reaction have been determined relative to the reference values of the 197Au(n,γ)198Au reaction, with σo,Au = 98.65 ± 0.09 barn and Io,Au = 1550 ± 28 barn. The present thermal neutron cross section has been determined to be σo,Sc = 27.5 ± 0.8 barn. According to the definition of cadmium cut-off energy at 0.55 eV, the present resonance integral cross section has been determined to be Io,Sc = 12.4 ± 0.7 barn. The present results are compared with literature values and discussed.

  6. Thermal neutron capture and resonance integral cross sections of {sup 45}Sc

    Energy Technology Data Exchange (ETDEWEB)

    Van Do, Nguyen; Duc Khue, Pham; Tien Thanh, Kim [Institute of Physics, Vietnam Academy of Science and Technology, 10 Dao Tan, Hanoi (Viet Nam); Thi Hien, Nguyen [Institute of Physics, Vietnam Academy of Science and Technology, 10 Dao Tan, Hanoi (Viet Nam); Department of Physics and Center for High Energy Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Kim, Guinyun, E-mail: gnkim@knu.ac.kr [Department of Physics and Center for High Energy Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Kim, Kwangsoo [Department of Physics and Center for High Energy Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Shin, Sung-Gyun; Cho, Moo-Hyun [Department of Advanced Nuclear Engineering, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Lee, Manwoo [Research Center, Dongnam Institute of Radiological and Medical Science, Busan 619-953 (Korea, Republic of)

    2015-11-01

    The thermal neutron cross section (σ{sub 0}) and resonance integral (I{sub 0}) of the {sup 45}Sc(n,γ){sup 46}Sc reaction have been measured relative to that of the {sup 197}Au(n,γ){sup 198}Au reaction by means of the activation method. High-purity natural scandium and gold foils without and with a cadmium cover of 0.5 mm thickness were irradiated with moderated pulsed neutrons produced from the Pohang Neutron Facility (PNF). The induced activities in the activated foils were measured with a high purity germanium (HPGe) detector. In order to improve the accuracy of the experimental results the counting losses caused by the thermal (G{sub th}) and resonance (G{sub epi}) neutron self-shielding, the γ-ray attenuation (F{sub g}) and the true γ-ray coincidence summing effects were made. In addition, the effect of non-ideal epithermal spectrum was also taken into account by determining the neutron spectrum shape factor (α). The thermal neutron cross-section and resonance integral of the {sup 45}Sc(n,γ){sup 46}Sc reaction have been determined relative to the reference values of the {sup 197}Au(n,γ){sup 198}Au reaction, with σ{sub o,Au} = 98.65 ± 0.09 barn and I{sub o,Au} = 1550 ± 28 barn. The present thermal neutron cross section has been determined to be σ{sub o,Sc} = 27.5 ± 0.8 barn. According to the definition of cadmium cut-off energy at 0.55 eV, the present resonance integral cross section has been determined to be I{sub o,Sc} = 12.4 ± 0.7 barn. The present results are compared with literature values and discussed.

  7. Measurements of thermal neutron fluence proton therapy for head and neck; Medidas de la fluencia de neutrones termicos en protonterapia de cabeza y cuello

    Energy Technology Data Exchange (ETDEWEB)

    Lagares, J. I.; Sansaloni, F.; Terron, J. A.; Muniz, J. L.; Exposito, M. r.; Nieto-Camero, J.J.; Korf, A.; Arce, P.; Nunez, L.; Loubser, M.; Sanchez-Doblado, F.

    2011-07-01

    We present an estimate of the distribution of thermal neutron fluence proton therapy for head and neck using an anthropomorphic phantom called NORMA. It also represents a small part within a larger project which aims to develop a risk prediction model due to neutron radiation generated indirectly in radiotherapy.

  8. Neutron star in the presence of strong magnetic field

    Indian Academy of Sciences (India)

    K K Mohanta; R Mallick; N R Panda; L P Singh; P K Sahu

    2014-05-01

    Compact stars such as neutron stars (NS) can have either hadronic or exotic states like strange quark or colour superconducting matter. Stars can also have a quark core surrounded by hadronic matter, known as hybrid stars (HS). The HS is likely to have a mixed phase in between the hadron and the quark phases. Observational results suggest huge surface magnetic field in certain NS. Therefore, we study here the effect of strong magnetic field on the respective equation of states (EOS) of matter under extreme conditions. We further study the hadron–quark phase transition in the interiors of NS giving rise to HS in the presence of strong magnetic field. The hadronic matter EOS is described based on RMF theory and we include the effects of strong magnetic fields leading to Landau quantization of the charged particles. For quark phase, we use the simple Massachusetts Institute of Technology (MIT) bag model, assuming density-dependent bag pressure and magnetic field. The magnetic field strength increases from the surface to the centre of the star. We construct the intermediate mixed phase using Glendenning conjecture. The magnetic field softens the EOS of both the matter phases. We finally study, the mass–radius relationship for such types of mixed HS, calculating their maximum mass, and compare them with the recent observations of pulsar PSR J1614-2230, which is about 2 solar mass.

  9. International key comparison of neutron fluence measurements in monoenergetic neutron fields: CCRI(III)-K11

    Science.gov (United States)

    Gressier, V.; Bonaldi, A. C.; Dewey, M. S.; Gilliam, D. M.; Harano, H.; Masuda, A.; Matsumoto, T.; Moiseev, N.; Nico, J. S.; Nolte, R.; Oberstedt, S.; Roberts, N. J.; Röttger, S.; Thomas, D. J.

    2014-01-01

    To ensure the validity of their national standards, National Metrology Institutes (NMIs) participate regularly in international comparisons. In the area of neutron metrology, Section III of the Consultative Committee for Ionizing Radiation is in charge of the organization of these comparisons. From September 2011 to October 2012, the eleventh key comparison, named CCRI(III)-K11, took place at the AMANDE facility of the LNE-IRSN, in France. Participants from nine NMIs came with their own primary reference instruments, or instruments traceable to primary standards, with the aim of determining the neutron fluence, at 1 m distance from the target in vacuum, per monitor count at four monoenergetic neutron fields: 27 keV, 565 keV, 2.5 MeV and 17 MeV. The key comparison reference values (KCRV) were evaluated as the weighted mean values of the results provided by seven participants. The uncertainties of each KCRV are between 0.9% and 1.7%. The degree of equivalence (DoE), defined as the deviation of the result reported by the laboratories for each energy from the corresponding KCRV, and the associated expanded uncertainty are also reported and discussed. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Compensated gadolinium-loaded plastic scintillators for thermal neutron detection (and counting)

    Energy Technology Data Exchange (ETDEWEB)

    Dumazert, Jonathan; Coulon, Romain; Bertrand, Guillaume H. V.; Hamel, Matthieu; Sguerra, Fabien; Dehe-Pittance, Chrystele; Normand, Stephane [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 99 Gif-sur-Yvette, (France); Mechin, Laurence [CNRS, UCBN, Groupe de Recherche en Informatique, Image, Automatique et Instrumentation de Caen, 4050 Caen, (France)

    2015-07-01

    Plastic scintillator loading with gadolinium-rich organometallic complexes shows a high potential for the deployment of efficient and cost-effective neutron detectors. Due to the low-energy photon and electron signature of thermal neutron capture by gadolinium-155 and gadolinium-157, alternative treatment to Pulse Shape Discrimination has to be proposed in order to display a trustable count rate. This paper discloses the principle of a compensation method applied to a two-scintillator system: a detection scintillator interacts with photon radiation and is loaded with gadolinium organometallic compound to become a thermal neutron absorber, while a non-gadolinium loaded compensation scintillator solely interacts with the photon part of the incident radiation. Posterior to the nonlinear smoothing of the counting signals, a hypothesis test determines whether the resulting count rate after photon response compensation falls into statistical fluctuations or provides a robust image of a neutron activity. A laboratory prototype is tested under both photon and neutron irradiations, allowing us to investigate the performance of the overall compensation system in terms of neutron detection, especially with regards to a commercial helium-3 counter. The study reveals satisfactory results in terms of sensitivity and orientates future investigation toward promising axes. (authors)

  11. Effect of magnetized phonons on electrical and thermal conductivity of neutron star crust

    CERN Document Server

    Baiko, D A

    2016-01-01

    We study electrical and thermal conductivities of degenerate electrons emitting and absorbing phonons in a strongly magnetized crystalline neutron star crust. We take into account modification of the phonon spectrum of a Coulomb solid of ions caused by a strong magnetic field. Boltzmann transport equation is solved using a generalized variational method. The ensuing three-dimensional integrals over the transferred momenta are evaluated by two different numerical techniques, the Monte-Carlo method and a regular integration over the first Brillouin zone. The results of the two numerical approaches are shown to be in a good agreement. An appreciable growth of electrical and thermal resistivities is reported at quantum and intermediate temperatures $T \\lesssim 0.1 T_{\\rm p}$ ($T_{\\rm p}$ is the ion plasma temperature) in a wide range of chemical compositions and mass densities of matter even for moderately magnetized crystals $\\omega_{\\rm B} \\sim \\omega_{\\rm p}$ ($\\omega_{\\rm B}$ and $\\omega_{\\rm p}$ are the ion ...

  12. Thermal and electric conductivities of Coulomb crystals in neutron stars and white dwarfs

    CERN Document Server

    Baiko, D A

    1996-01-01

    Thermal and electric conductivities are calculated for degenerate electrons scattered by phonons in a crystal made of atomic nuclei. The exact phonon spectrum and the Debye--Waller factor are taken into account. Monte Carlo calculations are performed for body-centered cubic (bcc) crystals made of C, O, Ne, Mg, Si, S, Ca, and Fe nuclei in the density range from 10^3 to 10^{11} g cm^{-3} at temperatures lower than the melting temperature but higher than the temperature at which the Umklapp processes begin to be "frozen out". A simplified method of calculation is proposed, which makes it possible to describe the results in terms of simple analytic expressions, to extend these expressions to any species of nucleus, and to consider face-centered cubic (fcc) crystals. The kinetic coefficients are shown to depend tangibly on the lattice type. The results are applicable to studies of heat transfer and evolution of the magnetic field in the cores of white dwarfs and in the crusts of neutron stars. The thermal drift of...

  13. Alternative method for thermal neutron flux measurements based on common boric acid as converter and Lr-15 detectors

    Energy Technology Data Exchange (ETDEWEB)

    Palacios, D.; Greaves, E. D.; Sajo B, L.; Barros, H. [Universidad Simon Bolivar, Laboratorio de Fisica Nuclear, Apdo. Postal 89000, Caracas (Venezuela, Bolivarian Republic of); Ingles, R. [Universidad Nacional de San Antonio Abad del Cusco, Av. de la Cultura No. 733, Cusco (Peru)

    2010-02-15

    A method to determine the flux and angular distribution of thermal neutrons with the use of Lr-115 detectors was developed. The use of the Lr-115 detector involves the exposure of a pressed boric acid sample (tablet) as a target, in tight contact with the track detector, to a flux of thermalized neutrons. The self-absorption effects in thin films or foil type thermal neutron detectors can be neglected by using the Lr-115 detector and boric acid tablet setup to operate via backside irradiation. The energy window and the critical angle-residual energy curve were determined by comparisons between the experimental and simulated track parameters. A computer program was developed to calculate the detector registration efficiency, so that the thermal neutron flux can be calculated from the track densities induced in the Lr-115 detector using the derived empirical formula. The proposed setup can serves as directional detector of thermal neutrons. (Author)

  14. Bis(pinacolato)diboron as an additive for the detection of thermal neutrons in plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Mahl, Adam [Department of Physics and the Nuclear Science and Engineering Center (NuSEC), Colorado School of Mines, Golden, CO 80401 (United States); Yemam, Henok A.; Stuntz, John [Department of Chemistry and Geochemistry and the Materials Science Program Colorado School of Mines, Golden, CO 80401 (United States); Remedes, Tyler [Department of Physics and the Nuclear Science and Engineering Center (NuSEC), Colorado School of Mines, Golden, CO 80401 (United States); Sellinger, Alan [Department of Chemistry and Geochemistry and the Materials Science Program Colorado School of Mines, Golden, CO 80401 (United States); Greife, Uwe, E-mail: ugreife@mines.edu [Department of Physics and the Nuclear Science and Engineering Center (NuSEC), Colorado School of Mines, Golden, CO 80401 (United States)

    2016-04-21

    A readily available and inexpensive boron compound was tested as an additive for the detection of thermal neutrons in plastic scintillators. Bis(pinacolato)diboron (B{sub 2}Pin{sub 2}) was determined to be a compatible boron source (8.51 wt% boron, 1.70 wt% {sup 10}B) in poly(vinyltoluene) based matrices. Plastic scintillator blends of 1–20 wt% 2,5-diphenyloxazole (PPO), 0.1 wt% 1,4-bis(5-phenyloxazol-2-yl) benzene (POPOP) and 1–15 wt% B{sub 2}Pin{sub 2} were prepared that provided optical clarity, good mechanical properties, and the capability of thermal neutron detection. Independent of B{sub 2}Pin{sub 2} concentration, strong {sup 10}B neutron capture signals around 90 keV{sub ee} were observed at essentially constant light output. Increasing PPO concentration allowed for the use of pulse shape discrimination (PSD) in both fast and thermal neutron detection. High PPO concentrations appear to cause additional alpha quenching that affected the {sup 10}B neutron capture signal. Aging effects after storage in air for several months were observed, which led to degradation of performance and in some samples of mechanical stability.

  15. High Field Pulsed Magnets for Neutron Scattering at the Spallation Neutron Source

    Science.gov (United States)

    Granroth, G. E.; Lee, J.; Fogh, E.; Christensen, N. B.; Toft-Petersen, R.; Nojiri, H.

    2015-03-01

    A High Field Pulsed Magnet (HFPM) setup, is in use at the Spallation Nuetron Source(SNS), Oak Ridge National Laboratory. With this device, we recently measured the high field magnetic spin structure of LiNiPO4. The results of this study will be highlighted as an example of possible measurements that can be performed with this device. To further extend the HFPM capabilities at SNS, we have learned to design and wind these coils in house. This contribution will summarize the magnet coil design optimization procedure. Specifically by varying the geometry of the multi-layer coil, we arrive at a design that balances the maximum field strength, neutron scattering angle, and the field homogeneity for a specific set of parameters. We will show that a 6.3kJ capacitor bank, can provide a magnetic field as high as 30T for a maximum scattering angle around 40° with homogeneity of +/- 4 % in a 2mm diameter spherical volume. We will also compare the calculations to measurements from a recently wound test coil. This work was supported in part by the Lab Directors' Research and Development Fund of ORNL.

  16. Neutron and gamma field investigations in the VVER-1000 mock-up concrete shielding on the reactor LR-0

    Energy Technology Data Exchange (ETDEWEB)

    Zaritsky, S.; Egorov, A. [National Research Center, Kurchatov Inst., Moscow 123182 (Russian Federation); Osmera, B.; Marik, M.; Rypar, V. [Research Centre Rez Ltd., Rez 25068 (Czech Republic); Cvachovec, F. [Univ. of Defense, Brno 61200 (Czech Republic); Kolros, A. [Czech Technical Univ., Prague 18000 (Czech Republic)

    2011-07-01

    Two sets of neutron and gamma field investigations were carried out in the dismountable model of radiation shielding of the VVER-1000 mock-up on the LR-0 reactor. First, measurements and calculations of the {sup 3}He(n,p)T reaction rate and fast neutrons and gamma flux spectra in the operational neutron monitor channel inside a concrete shielding for different shapes and locations of the channel (cylindrical channel in a concrete, channels with collimator in a concrete, cylindrical channel in a graphite). In all cases measurements and calculations of the {sup 3}He(n,p)T reaction rate were done with and without an additional moderator-polyethylene insert inside the channel. Second, measurements and calculations of the {sup 3}He(n,p)T reaction rate spatial distribution inside a concrete. The {sup 3}He(n,p)T reaction rate measurements and calculations were carried out exploring the relative thermal neutron density in the channels and its space distribution in the concrete. Fast neutrons and gamma measurements were carried out with a stilbene (45 x 45 mm) scintillation spectrometer in the energy regions 0.5-10 MeV (neutrons) and 0.2-10 MeV (gammas). (authors)

  17. Neutron Flux Density Measured by Analysis of Annealing Heat

    Institute of Scientific and Technical Information of China (English)

    WANG; Fan; SHI; Yong-qian; ZHU; Qing-fu; LU; Jin; LI; Lai-dong

    2015-01-01

    Neutron flux density measurement by thermal analysis is a new method different from the previous.This method is first put the sample to the neutron field.Second,measure the annealingheat of the sample.Find out the suitable mixture of crystal boron and apatite to measure the neutron flux density.Then put the sample to the neutron field in

  18. Initial thermal characterization of the Cornell cold neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Spern, S.A.; Atwood, A.G.; Clark, D.D.; Hossain, T.Z. [Cornell Univ., Ithaca, NY (United States)

    1995-12-31

    The completed full-scale Cornell cold neutron source, an integral component of the Cornell cold neutron beam facility, has undergone testing prior to its insertion (and consequent activation) in the Cornell 500-kW TRIGA reactor. The source consists of an organic moderator (mesitylene) contained within an aluminum chamber, which is cooled by conduction through a 99.999+ pure 1.90-cm-diam copper rod 267 cm long, coupled to the second (4-W capacity), cooler stage of a helium cryorefrigerator. Approximately 18 h is required to achieve equilibrium chamber temperatures. To lower the radiational T 4 load on the second stage, the chamber and rod are surrounded by an active heat shield, consisting of 99.99+ pure copper (oxygen-free high conductivity) coupled to the first 60-W capacity stage of the cryorefrigerator. Other components include the associated mesitylene handling system (MHS) and vacuum system.

  19. Thermal-neutron cross sections and resonance integrals of 138Ba and 141Pr using Am-Be neutron source

    Science.gov (United States)

    Panikkath, Priyada; Mohanakrishnan, P.

    2016-09-01

    The thermal-neutron capture cross sections and resonance integrals of 138Ba(n, γ)139Ba and 141Pr(n, γ)142Pr were measured by activation method using an isotopic Am-Be neutron source. The estimations were with respect to that of 55Mn(n, γ)56Mn and 197Au(n, γ)198Au reference monitors. The measured thermal-capture cross section of 138 Ba with respect to 55 Mn is 0.410±0.023 b and with respect to 197 Au is 0.386±0.019 b. The measured thermal-capture cross section of 141 Pr with respect to 55 Mn is 11.36±1.29 b and with respect to 197 Au is 10.43±1.14 b. The resonance integrals for 138 Ba are 0.380±0.033 b (55 Mn) and 0.364±0.027 b (197 Au) and for 141 Pr are 21.05±2.88 b (55 Mn) and 15.27±1.87 b (197 Au). The comparison between the present measurements and various reported values are discussed. The cross sections corresponding to the selected isotopes are measured using an Am-Be source facility for the first time.

  20. X-Ray and Neutron Diffraction Studies on Thermal Parameters of Thalous Bromide

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Thermal parameters of TIBr were determined using both X-ray and neutron diffraction techniques. The data was analysed by Rietveld profile refinement procedure. From the neutron diffraction data, due to weak odd-order reflections, it was not possible to determine the individual thermal parameters. The X-ray diffraction measurements yielded BT1=0.296(5) nm2 and BBr=0.162(5) nm2. The overall isotropic value, B was 0.252(7) nm2 which is in good agreement with B=0.230(8) nm2 obtained from present neutron diffraction measurements. The present values are also in good agreement with theoretical estimates obtained from the shell models.

  1. Thermal neutron fluence in a treatment room with a Varian linear accelerator at a medical university hospital

    Science.gov (United States)

    Liu, Wen-Shan; Changlai, Sheng-Pin; Pan, Lung-Kwang; Tseng, Hsien-Chun; Chen, Chien-Yi

    2011-09-01

    The indium foil activation technique has been employed to measure thermal neutron fluences ( Φth) among various locations in the treatment room with a 20×20 cm 2 field size and a 15 and 10 MV X-ray beam. Spatial Φth are visualized using colored three-dimensional graphical representations; intensities are up to (1.97±0.13)×10 5 and (1.46±0.13)×10 4 n cm -2/Gy-X at isocenter, respectively. The Φth is found to increase with the X-ray energy of the LINAC and decreases as it moves away from the beam center. However, thermal neutron exposure is not assessed in routine dosimetry planning and radiation assessment of patients since neutron dose contributes <1% of the given therapy dose. However, unlike the accelerated beam limited within the gantry window, photoneutrons are widely spread in the treatment room. Distributions of Φth were measured in water phantom irradiated with 15 MV X-ray beams. The shielding effect of the maze was also evaluated. The experimentally estimated Φth along the maze distance was fitted explicate and the tenth-value layer (TVL) was calculated and discussed. Use of a 10 cm-thick polyethylene door placed at the maze was suitable for radiation shielding.

  2. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 160A

    Energy Technology Data Exchange (ETDEWEB)

    Walker, B. J. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, D. T. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-06-06

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 160A which were measured by the Radiation Measurements Laboratory (RML).

  3. 6LiF oleic acid capped nanoparticles entrapment in siloxanes for thermal neutron detection

    Science.gov (United States)

    Carturan, S.; Maggioni, G.; Marchi, T.; Gramegna, F.; Cinausero, M.; Quaranta, A.; Palma, M. Dalla

    2016-07-01

    The good light output of siloxane based scintillators as displayed under γ-rays and α particles has been exploited here to obtain clear and reliable response toward thermal neutrons. Sensitization towards thermal neutrons has been pursued by adding 6LiF, in form of nanoparticles. Aiming at the enhancement of compatibility between the inorganic nanoparticles and the low polarity, siloxane based surrounding medium, oleic acid-capped 6LiF nanoparticles have been synthesized by thermal decomposition of Li trifluoroacetate. Thin pellets siloxane scintillator maintained their optical transmittance up to weight load of 2% of 6Li. Thin samples with increasing 6Li concentration and thicker ones with fixed 6Li amount have been prepared and tested with several sources (α, γ-rays, moderated neutrons). Light output as high as 80% of EJ212 under α irradiation was measured with thin samples, and negligible changes have been observed as a result of 6LiF addition. In case of thick samples, severe light loss has been observed, as induced by opacity. Nevertheless, thermal neutrons detection has been assessed and the data have been compared with GS20, based on Li glass, taken as a reference material.

  4. Monte Carlo simulations to advance characterisation of landmines by pulsed fast/thermal neutron analysis

    NARCIS (Netherlands)

    Maucec, M.; Rigollet, C.

    2004-01-01

    The performance of a detection system based on the pulsed fast/thermal neutron analysis technique was assessed using Monte Carlo simulations. The aim was to develop and implement simulation methods, to support and advance the data analysis techniques of the characteristic gamma-ray spectra, potentia

  5. Advances in thermal hydraulic and neutronic simulation for reactor analysis and safety

    Energy Technology Data Exchange (ETDEWEB)

    Tentner, A.M.; Blomquist, R.N.; Canfield, T.R.; Ewing, T.F.; Garner, P.L.; Gelbard, E.M.; Gross, K.C.; Minkoff, M.; Valentin, R.A.

    1993-03-01

    This paper describes several large-scale computational models developed at Argonne National Laboratory for the simulation and analysis of thermal-hydraulic and neutronic events in nuclear reactors and nuclear power plants. The impact of advanced parallel computing technologies on these computational models is emphasized.

  6. Review of neutron calibration facilities and monitoring techniques: new needs for emerging fields.

    Science.gov (United States)

    Gressier, V

    2014-10-01

    Neutron calibration facilities and monitoring techniques have been developed since the middle of the 20th century to support research and nuclear power energy development. The technical areas needing reference neutron fields and related instruments were mainly cross section measurements, radiation protection, dosimetry and fission reactors, with energy ranging from a few millielectronvolts to about 20 MeV. The reference neutron fields and calibration techniques developed for these purposes will be presented in this paper. However, in recent years, emerging fields have brought new needs for calibration facilities and monitoring techniques. These new challenges for neutron metrology will be exposed with their technical difficulties.

  7. Entanglement Between Qubits Interacting with Thermal Field

    Directory of Open Access Journals (Sweden)

    Bashkirovaa E.K.

    2015-01-01

    Full Text Available We have investigated the entanglement between two dipole coupled two-level artificial atoms (superconducting qubits, ion, spins etc.. The model, in which only one atom is trapped in an lossless cavity and interacts with single-mode thermal field, and the other one can be spatially moved freely outside the cavity has been carried out. We have considered the effect of the atomic coherence on the entanglement behavior. We have shown that a thermal field might cause high entanglement between the atoms both for coherent and incoherent initial atomic states only for small values of cavity mean photon number. We have also derived that the degree of entanglement is weakly dependent on the strength of dipole-dipole interaction for coherent initial states. In the considered model the atoms would get entangled even when both atoms are initially in the excited state.

  8. Measurements of thermal- and slow-neutron dose distributions in ordinary concrete shield using a reactor neutron beam of different energy ranges

    Energy Technology Data Exchange (ETDEWEB)

    Megahid, R.M.; Makarious, A.S.; El-Kolaly, M.A.; Afifi, Y.A.

    1980-01-01

    Experimental studies on the distribution and attenuation of thermal and slow neutron doses in ordinary concrete shield have been carried-out. A collimated beam of reactor neutrons emitted from one of the horizontal channels of the ET-RR-1 reactor was used. Measurements were performed using, a direct beam, cadmium filtered beam and boron carbide filtered beam. The neutron doses were measured using thermolumin-escent Li/sub 2/B/sub 4/O/sub 7/ detectors. The measured data have been analyzed and a group of attenuation curves were given for beams of reactor neutrons of different energy. These curves show that cadmium and boron carbide filters tend to decrease the neutron doses specially at the beginning of penetration. The data were transformed to that which would be obtained using neutron sources of different geometries.

  9. Neutron-capture Cl-36, Ca-41, Ar-36, and Sm-150 in large chondrites: Evidence for high fluences of thermalized neutrons

    Science.gov (United States)

    Bogard, D. D.; Nyquist, L. E.; Bansal, B. M.; Garrison, D. H.; Wiesmann, H.; Herzog, G. F.; Albrecht, A. A.; Vogt, S.; Klein, J.

    1995-01-01

    We have measured significant concentrations of Cl-36, Ca-41, Ar-36 from decay of Cl-36, and Sm-150 produced from the capture of thermalized neutrons in the large Chico L6 chondrite. Activities of Cl-36 and Ca-41, corrected for a high-energy spallogenic component and a terrestrial age of approximately 50 ka, give average neutron-capture production rates of 208 atoms/min/g-Cl and 1525 atoms/min/kg-Ca, which correspond to thermal neutron (n) fluxes of 6.2 n/sq cm/s and 4.3 n/sq cm/s, respectively. If sustained for the approximately 65 Ma single-stage, cosmic ray exposure age of Chico, these values correspond to thermal neutron fluences of approximately 1.3 x 10(exp 16) and 0.8 x 10(exp 16) n/sq cm for Cl-36 and Ca-41, respectively. Stepwise temperature extraction of Ar in Chico impact melt shows Ar-36/Ar-38 ratios as large as approximately 9. The correlation of high Ar-36/Ar-38 with high Cl/Ca phases in neutron-irradiated Chico indicates that the excess Ar-36 above that expected from spallation is due to decay of neutron-produced Cl-36. Excess Ar-36 in Chico requires a thermal neutron fluence of 0.9-1.7 x 10(exp 16) n/sq cm. Decreases in Sm-149/Sm-152 due to neutron-capture by Sm-149 correlate with increases in Sm-150/Sm-152 for three samples of Chico, and one of the Torino H-chondrite. The 0.08% decrease in Sm-149 shown by Chico corresponds to a neutron fluence of 1.23 x 10(exp 16) n/sq cm. This fluence derived from Sm considers capture of epithermal neutrons and effects of chemical composition on the neutron energy distribution. Excess Ar-36 identified in the Arapahoe, Bruderheim, and Torino chondrites and the Shallowater aubrite suggest exposure to neutron fluences of approximately 0.2-0.2 x 10(exp 16) n/sq cm. Depletion of Sm-149 in Torino and the LEW86010 angrite suggest neutron fluences of 0.8 x 10(exp 16) n/sq cm and 0.25 x 10(exp 16) n/sq cm, respectively. Neutron fluences of approximately 10(exp 16) n/sq cm in Chico are almost as large as those previously

  10. Calculations of the thermal and fast neutron fluxes in the Syrian miniature neutron source reactor using the MCNP-4C code.

    Science.gov (United States)

    Khattab, K; Sulieman, I

    2009-04-01

    The MCNP-4C code, based on the probabilistic approach, was used to model the 3D configuration of the core of the Syrian miniature neutron source reactor (MNSR). The continuous energy neutron cross sections from the ENDF/B-VI library were used to calculate the thermal and fast neutron fluxes in the inner and outer irradiation sites of MNSR. The thermal fluxes in the MNSR inner irradiation sites were also measured experimentally by the multiple foil activation method ((197)Au (n, gamma) (198)Au and (59)Co (n, gamma) (60)Co). The foils were irradiated simultaneously in each of the five MNSR inner irradiation sites to measure the thermal neutron flux and the epithermal index in each site. The calculated and measured results agree well.

  11. Thermal variational principle and gauge fields

    CERN Document Server

    Schröder, Y

    1996-01-01

    A Feynman--Jensen version of the thermal variational principle is applied to hot gauge fields, abelian as well as nonabelian\\,: scalar electrodynamics (without scalar self-coupling) and the gluon plasma. The perturbatively known self-energies are shown to derive by variation from a free quadratic (''gaussian'') trial Lagrangian. Independence of the covariant gauge fixing parameter is reached (within the order g^2 studied and for scalar ED) after a reformulation of the partition function such that it depends on only even powers of the gauge field. This way, however, the potential non-perturbative power of the calculus seems to be ruined.

  12. Image processing analysis of nuclear track parameters for CR-39 detector irradiated by thermal neutron

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jobouri, Hussain A., E-mail: hahmed54@gmail.com; Rajab, Mustafa Y., E-mail: mostafaheete@gmail.com [Department of Physics, College of Science, AL-Nahrain University, Baghdad (Iraq)

    2016-03-25

    CR-39 detector which covered with boric acid (H{sub 3}Bo{sub 3}) pellet was irradiated by thermal neutrons from ({sup 241}Am - {sup 9}Be) source with activity 12Ci and neutron flux 10{sup 5} n. cm{sup −2}. s{sup −1}. The irradiation times -T{sub D} for detector were 4h, 8h, 16h and 24h. Chemical etching solution for detector was sodium hydroxide NaOH, 6.25N with 45 min etching time and 60 C° temperature. Images of CR-39 detector after chemical etching were taken from digital camera which connected from optical microscope. MATLAB software version 7.0 was used to image processing. The outputs of image processing of MATLAB software were analyzed and found the following relationships: (a) The irradiation time -T{sub D} has behavior linear relationships with following nuclear track parameters: i) total track number - N{sub T} ii) maximum track number - MRD (relative to track diameter - D{sub T}) at response region range 2.5 µm to 4 µm iii) maximum track number - M{sub D} (without depending on track diameter - D{sub T}). (b) The irradiation time -T{sub D} has behavior logarithmic relationship with maximum track number - M{sub A} (without depending on track area - A{sub T}). The image processing technique principally track diameter - D{sub T} can be take into account to classification of α-particle emitters, In addition to the contribution of these technique in preparation of nano- filters and nano-membrane in nanotechnology fields.

  13. Apparatus for nuclear transmutation and power production using an intense accelerator-generated thermal neutron flux

    Science.gov (United States)

    Bowman, Charles D.

    1992-01-01

    Apparatus for nuclear transmutation and power production using an intense accelerator-generated thermal neutron flux. High thermal neutron fluxes generated from the action of a high power proton accelerator on a spallation target allows the efficient burn-up of higher actinide nuclear waste by a two-step process. Additionally, rapid burn-up of fission product waste for nuclides having small thermal neutron cross sections, and the practicality of small material inventories while achieving significant throughput derive from employment of such high fluxes. Several nuclear technology problems are addressed including 1. nuclear energy production without a waste stream requiring storage on a geological timescale, 2. the burn-up of defense and commercial nuclear waste, and 3. the production of defense nuclear material. The apparatus includes an accelerator, a target for neutron production surrounded by a blanket region for transmutation, a turbine for electric power production, and a chemical processing facility. In all applications, the accelerator power may be generated internally from fission and the waste produced thereby is transmuted internally so that waste management might not be required beyond the human lifespan.

  14. Radiation detector based on 4H-SiC used for thermal neutron detection

    Science.gov (United States)

    Zaťko, B.; Šagátová, A.; Sedlačková, K.; Boháček, P.; Sekáčová, M.; Kohout, Z.; Granja, C.; Nečas, V.

    2016-11-01

    In this work we have focused on detection of thermal neutrons generated by 239Pu-Be isotopic neutron source. A high quality liquid phase epitaxial layer of 4H-SiC was used as a detection region. The thickness of the layer was 70 μ m and the diameter of circular Au/Ni Schottky contact was 4.5 mm. Around the Schottky contact two guard rings were created. The detector structure was first examined as a detector of protons and alpha particles for energy calibration. Monoenergetic protons of energies from 300 keV up to 1.9 MeV were used for detector energy calibration and a good linearity was observed. The energy resolution of 35 keV was obtained for 1.9 MeV protons. The 6LiF conversion layer was applied on the detector Schottky contact. In the experiment we used different thicknesses of conversion layers from 5 μ m up to 35 μ m. Measured detected spectra show two parts corresponding to alpha particles detection in lower energy channels and 3H in higher energy channels. We have also performed simulations of thermal neutron detection using MCNPX (Monte Carlo N-particle eXtended) code. The detection efficiency and the detector response to thermal neutrons was calculated with respect to the 6LiF layer thickness. The detection efficiency calculation is found to be in good agreement with the experiment.

  15. NUMERICAL SIMULATION OF TRANSIENT THERMAL FIELD IN LASER MELTING PROCESS

    Institute of Scientific and Technical Information of China (English)

    姚国凤; 陈光南

    2004-01-01

    Numerical simulation of thermal field was studied in laser processing. The 3 -D finite element model of transient thermal calculation is given by thermal conductive equation.The effects of phase transformation latent are considered. Numerical example is given to verify the model. Finally the real example of transient thermal field is given.

  16. A model for non-thermalized neutron spectra emitted from para-hydrogen

    DEFF Research Database (Denmark)

    Schönfeldt, Troels; Batkov, K.; Klinkby, Esben Bryndt

    2016-01-01

    to the high radiation environment near the moderator and cooling demands. One of the very popular materials, used at J-PARC and planed for ESS, is the spin singlet state of H2, para-hydrogen. This study assesses the non-Maxwellian neutron spectral structure achieved in para-hydrogen moderators, which is due...... to the complexity of the inelastic scattering cross section below 50 meV. The analytical description of a thermalized spectrum with slowing down components are discussed, then a formula is developed which is a good description of this non-equilibrium para-hydrogen neutron spectrum.These analytical descriptions...

  17. Thermally-Activated Post-Glitch Response of the Neutron Star Inner Crust and Core

    CERN Document Server

    Link, Bennett

    2013-01-01

    Pinning of superfluid vortices is predicted to prevail throughout much of a neutron star. Here I develop a description of the coupling through thermally-activated vortex slippage}, and calculate the post-glitch response of a neutron star to a spin glitch. The theory has three robust conclusions: 1) If vortex pinning occurs in the core, typical large glitches decouple the core superfluid from the charged components over observable timescales. Core response to a glitch has a distinct observational signature that could be identified through analyses of existing and future timing data. 2) Post-glitch response over short timescales (days) in pulsars with large glitches (fractional spin jumps of $\\Delta\

  18. Study of silicon+6LiF thermal neutron detectors: GEANT4 simulations versus real data

    Science.gov (United States)

    Meo, S. Lo; Cosentino, L.; Mazzone, A.; Bartolomei, P.; Finocchiaro, P.

    2017-09-01

    Research and development on alternative thermal neutron detection technologies and methods are nowadays needed as a possible replacement of 3He-based ones. Commercial solid state silicon detectors, coupled with neutron converter layers containing 6Li, have been proved to represent a viable solution for several applications as present in the literature. In order to better understand the detailed operation and the response and efficiency of such detectors, a series of dedicated GEANT4 simulations were performed and compared with real data collected in a few different configurations. The results show an excellent agreement between data and simulations, indicating that the behavior of the detector is fully understood.

  19. Monte Carlo Calculations for Neutron and Gamma Radiation Fields on a Fast Neutron Irradiation Device

    Science.gov (United States)

    Vieira, A.; Ramalho, A.; Gonçalves, I. C.; Fernandes, A.; Barradas, N.; Marques, J. G.; Prata, J.; Chaussy, Ch.

    We used the Monte Carlo program MCNP to calculate the neutron and gamma fluxes on a fast neutron irradiation facility being installed on the Portuguese Research Reactor (RPI). The purpose of this facility is to provide a fast neutron beam for irradiation of electronic circuits. The gamma dose should be minimized. This is achieved by placing a lead shield preceded by a thin layer of boral. A fast neutron flux of the order of 109 n/cm2s is expected at the exit of the tube, while the gamma radiation is kept below 20 Gy/h. We will present results of the neutron and gamma doses for several locations along the tube and different thickness of the lead shield. We found that the neutron beam is very collimated at the end of the tube with a dominant component on the fast region.

  20. Monte Carlo simulation of a very high resolution thermal neutron detector composed of glass scintillator microfibers.

    Science.gov (United States)

    Song, Yushou; Conner, Joseph; Zhang, Xiaodong; Hayward, Jason P

    2016-02-01

    In order to develop a high spatial resolution (micron level) thermal neutron detector, a detector assembly composed of cerium doped lithium glass microfibers, each with a diameter of 1 μm, is proposed, where the neutron absorption location is reconstructed from the observed charged particle products that result from neutron absorption. To suppress the cross talk of the scintillation light, each scintillating fiber is surrounded by air-filled glass capillaries with the same diameter as the fiber. This pattern is repeated to form a bulk microfiber detector. On one end, the surface of the detector is painted with a thin optical reflector to increase the light collection efficiency at the other end. Then the scintillation light emitted by any neutron interaction is transmitted to one end, magnified, and recorded by an intensified CCD camera. A simulation based on the Geant4 toolkit was developed to model this detector. All the relevant physics processes including neutron interaction, scintillation, and optical boundary behaviors are simulated. This simulation was first validated through measurements of neutron response from lithium glass cylinders. With good expected light collection, an algorithm based upon the features inherent to alpha and triton particle tracks is proposed to reconstruct the neutron reaction position in the glass fiber array. Given a 1 μm fiber diameter and 0.1mm detector thickness, the neutron spatial resolution is expected to reach σ∼1 μm with a Gaussian fit in each lateral dimension. The detection efficiency was estimated to be 3.7% for a glass fiber assembly with thickness of 0.1mm. When the detector thickness increases from 0.1mm to 1mm, the position resolution is not expected to vary much, while the detection efficiency is expected to increase by about a factor of ten.

  1. Fabrication and characterization of solid-state thermal neutron detectors based on hexagonal boron nitride epilayers

    Energy Technology Data Exchange (ETDEWEB)

    Doan, T.C.; Majety, S.; Grenadier, S.; Li, J.; Lin, J.Y.; Jiang, H.X., E-mail: hx.jiang@ttu.edu

    2014-06-01

    Solid-state thermal neutron detectors with improved detection efficiencies are highly sought after for many applications. Hexagonal boron nitride (hBN) epilayers have been synthesized by metal organic chemical vapor deposition on sapphire substrates. Important material parameters including the mobility-lifetime (μτ) product and the thermal neutron absorption length (λ) have been measured. For hBN epilayers with a room temperature resistivity of 5.3×10{sup 10} Ω cm, the measured μτ product of electrons is 4.46×10{sup −8} cm{sup 2}/V and of holes is 7.07×10{sup −9} cm{sup 2}/V. The measured λ values are 277 μm and 77 μm for natural and {sup 10}B enriched hBN epilayers, respectively. Metal–semiconductor–metal detectors incorporating 0.3 µm thick hBN epilayers were fabricated. The reaction product pulse-height spectra were measured under thermal neutron irradiation produced by a {sup 252}Cf source moderated by high density polyethylene block. The measured pulse-height spectra revealed distinguishable peaks corresponding to the product energies of {sup 10}B and neutron reaction with the 0.84 MeV {sup 7}Li peak being the most prominent. The detectors exhibited negligible responses to gamma rays produced by {sup 137}Cs decay. Our results indicate that hBN epilayers are highly promising for realizing highly sensitive solid-state thermal neutron detectors with expected advantages resulting from semiconductor technologies, including compact size, light weight, ability to integrate with other functional devices, and low cost.

  2. Electrical conductivity of a warm neutron star crust in magnetic fields

    Science.gov (United States)

    Harutyunyan, Arus; Sedrakian, Armen

    2016-08-01

    We study the electrical conductivity of finite-temperature crust of a warm compact star which may be formed in the aftermath of a supernova explosion or a binary neutron star merger as well as when a cold neutron star is heated by accretion of material from a companion. We focus on the temperature-density regime where plasma is in the liquid state and, therefore, the conductivity is dominated by the electron scattering off correlated nuclei. The dynamical screening of this interaction is implemented in terms of the polarization tensor computed in the hard-thermal-loop effective field theory of QED plasma. The correlations of the background ionic component are accounted for via a structure factor derived from Monte Carlo simulations of one-component plasma. With this input we solve the Boltzmann kinetic equation in relaxation time approximation taking into account the anisotropy of transport due to the magnetic field. The electrical conductivity tensor is studied numerically as a function of temperature and density for carbon and iron nuclei as well as density-dependent composition of zero-temperature dense matter in weak equilibrium with electrons. We also provide accurate fit formulas to our numerical results as well as supplemental tables which can be used in dissipative magneto-hydrodynamics simulations of warm compact stars.

  3. Evaluation of neutronic characteristic of irradiation field in MEU6-core. Comparison of neutron flux and neutron spectrum in MEU6-core and Mixed-core

    Energy Technology Data Exchange (ETDEWEB)

    Nagao, Yoshiharu; Komukai, Bunsaku; Tabata, Toshio; Takeda, Takashi; Fujiki, Kazuo [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    1999-08-01

    In JMTR (Japan Materials Testing Reactor, 50 MW), the core configuration has been changed from previously employed Mixed-core (25 LEUs(low enrichment uranium (19.8%) fuel elements) and 2 MEUs (medium enrichment uranium (45%) fuel elements)) to MEU6-core (21 LEUs and 6 MEUs), since 125th operating cycle (started in Nov. 17, 1998). In order to investigate the effect of core configuration change on the irradiation tests, neutron flux distribution and neutron spectrum of irradiation field in MEU6-core were calculated by diffusion code CITATION and Monte Carlo code MCNP. As the result, it was confirmed that irradiation field in the MEU6-core has the neutronic characteristics almost equivalent to the irradiation field in the Mixed-core. (author)

  4. Spectrum evaluation at the filter-modified neutron irradiation field for neutron capture therapy in Kyoto University Research Reactor

    Science.gov (United States)

    Sakurai, Yoshinori; Kobayashi, Tooru

    2004-10-01

    The Heavy Water Neutron Irradiation Facility of the Kyoto University Research Reactor (KUR-HWNIF) was updated in March 1996, mainly to improve the facility for neutron capture therapy (NCT). In this facility, neutron beams with various energy spectra, from almost pure thermal to epithermal, are available. The evaluation of the neutron energy spectra by multi-activation-foil method was performed as a series of the facility characterization. The spectra at the normal irradiation position were evaluated for the combinations of heavy-water thickness of the spectrum shifter and the open-close condition of the cadmium and boral filters. The initial spectra were made mainly using a two-dimensional transport code, and the final spectra were obtained using an adjusting code. For the verification of the evaluated spectra, simulation calculations using a phantom were performed on the assumption of NCT-clinical-irradiation conditions. It resulted that the calculated data for the depth neutron-flux distributions were in good agreement with the experimental ones.

  5. Characterization of the neutron field of the {sup 241}AmBe in a calibration room; Caracterizacion del campo de neutrones del {sup 241} AmBe en una sala para calibracion

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R. [UAZ, A.P. 336, 98000 Zacatecas (Mexico); Gallego, E.; Lorente, A. [Universidad Politecnica de Madrid, C. Jose Gutierrez Abascal 2, 28006 Madrid (Spain)] e-mail: rvega@cantera.reduaz.mx

    2003-07-01

    The field of neutrons produced by an isotopic source of neutrons of {sup 241} Am Be had been characterized. The characterization was carried out modeling those relevant details of the calibration room and simulating the neutron transport at different distances of the source. The calculated spectra were used to determine the equivalent environmental dose rate. A series of experiments were carried out with the Bonner sphere spectrometric system to measure the spectra in the same points where the calculations were carried out and with these spectra the rates of environmental dose were calculated. By means of a one sphere dosemeter type Berthold the rates of environmental dose were measured. To the one to compare the calculated spectra and measured its were found small differences in the group of the thermal neutrons due to the elementary composition used during the simulation. When comparing the derived rates starting from the calculated spectra with those measured it was found a maxim difference smaller to 13%. (Author)

  6. A {mu}TPC detector for the characterization of low energy neutron fields

    Energy Technology Data Exchange (ETDEWEB)

    Golabek, C., E-mail: cedric.golabek@irsn.fr [Laboratoire de Metrologie et de Dosimetrie des Neutrons, IRSN Cadarache, 13115 Saint-Paul-Lez-Durance (France); Billard, J. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Joseph Fourier Grenoble 1, CNRS/IN2P3, Institut Polytechnique de Grenoble, 53 rue des Martyrs, 38026 Grenoble (France); Allaoua, A. [Laboratoire de Metrologie et de Dosimetrie des Neutrons, IRSN Cadarache, 13115 Saint-Paul-Lez-Durance (France); Bosson, G.; Bourrion, O.; Grignon, C.; Guillaudin, O. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Joseph Fourier Grenoble 1, CNRS/IN2P3, Institut Polytechnique de Grenoble, 53 rue des Martyrs, 38026 Grenoble (France); Lebreton, L., E-mail: lena.lebreton@irsn.fr [Laboratoire de Metrologie et de Dosimetrie des Neutrons, IRSN Cadarache, 13115 Saint-Paul-Lez-Durance (France); Mayet, F. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Joseph Fourier Grenoble 1, CNRS/IN2P3, Institut Polytechnique de Grenoble, 53 rue des Martyrs, 38026 Grenoble (France); Petit, M. [Laboratoire de Metrologie et de Dosimetrie des Neutrons, IRSN Cadarache, 13115 Saint-Paul-Lez-Durance (France); Richer, J.-P.; Santos, D. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Joseph Fourier Grenoble 1, CNRS/IN2P3, Institut Polytechnique de Grenoble, 53 rue des Martyrs, 38026 Grenoble (France)

    2012-06-21

    The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 8 keV up to 1 MeV. In this work we present simulations showing that such a detector, which allows the measurement of the ionization energy and the 3D reconstruction of the recoil nucleus, provides the determination of neutron energy and fluence of these neutron fields.

  7. A {\\mu}-TPC detector for the characterization of low energy neutron fields

    CERN Document Server

    Golabek, C; Allaoua, A; Bosson, G; Bourrion, O; Grignon, C; Guillaudin, O; Lebreton, L; Mayet, F; Petit, M; Richer, J -P; Santos, D

    2012-01-01

    The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 8 keV up to 1 MeV. In this work we present simulations showing that such a detector, which allows the measurement of the ionization energy and the 3D reconstruction of the recoil nucleus, provides the determination of neutron energy and fluence of these neutron fields.

  8. Two-step γ cascades following thermal neutron capture in Gd,157155

    Science.gov (United States)

    Valenta, S.; Bečvář, F.; Kroll, J.; Krtička, M.; Tomandl, I.

    2015-12-01

    Spectra of two-step γ cascades following neutron capture in Gd,157155 are measured using the two-Ge-detector facility installed at the thermal neutron beam of the research reactor LVR-15 at Řež. The main objective of this experiment is to obtain new information on photon strength functions, with the emphasis on the role of M 1 scissors-mode vibration. An analysis of accumulated γ -ray spectra, made within the statistical model, leads to the conclusion that the scissors mode significantly affects γ decay of all states of studied nuclei. Experimental data are compared to photon strength functions deduced from other experiments. Agreement of our results with those obtained from DANCE measurement of γ spectra following resonance neutron capture is obtained.

  9. Radiolysis of Boric Acid Solutions under Mixed Thermal and Fast Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Im, Heejung; Choi, Ke Chon; Yeon, Jeiwon; Song, Kyuseok; Jung Hoansung [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The thermal neutron irradiation of water samples containing neutron absorbers has not been published except for a paper reporting the experimental data obtained at high temperatures. However, irradiation or simulations of water and voluminous liquid samples with fast neutrons and gamma rays are frequently discussed in several published papers. Several water samples containing {sup 10}B-enriched boric acid, and natural and {sup 10}B-enriched mixed boric acids in the range of 0 to 2000 μg/mL for the function of {sup 10}B concentration, were irradiated to study the radiolysis of the cooling water containing boric acid. The concentration of natural boron in the primary coolant of pressurized water reactors (PWRs) is known to start at 1500 μg/mL, and boric acid is used for the purpose of nuclear reaction control.

  10. Measurement of gamma-ray production from thermal neutron capture on gadolinium for neutrino experiments

    Science.gov (United States)

    Yano, Takatomi

    2017-02-01

    Recently, several scientific applications of gadolinium are found in neutrino physics experiments. Gadolinium-157 is the nucleus, which has the largest thermal neutron capture cross-section among all stable nuclei. Gadolinium-155 also has the large cross-section. These neutron capture reactions provide the gamma-ray cascade with the total energy of about 8 MeV. This reaction is applied for several neutrino experiments, e.g. reactor neutrino experiments and Gd doped large water Cherenkov detector experiments, to recognize inverse-beta-decay reaction. A good Gd(n,γ) simulation model is needed to evaluate the detection efficiency of the neutron capture reaction, i.e. the efficiency of IBD detection. In this presentation, we will report the development and study status of a Gd(n,γ) calculation model and comparison with our experimental data taken at ANNRI/MLF beam line, J-PARC.

  11. Investigation of dose distribution in mixed neutron-gamma field of boron neutron capture therapy using N isopropylacrylamide gel

    Energy Technology Data Exchange (ETDEWEB)

    Bavarmegin, Elham; Sadremomtaz, Alireza [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Khalafi, Hossein; Kasesaz, Yaser [Dept. of Physics, University of Guilan, Rasht (Iran, Islamic Republic of); Khajeali, Azim [Medical Education Research Center, Tabriz (Iran, Islamic Republic of)

    2017-02-15

    Gel dosimeters have unique advantages in comparison with other dosimeters. Until now, these gels have been used in different radiotherapy techniques as a reliable dosimetric tool. Because dose distribution measurement is an important factor for appropriate treatment planning in different radiotherapy techniques, in this study, we evaluated the ability of the N-isopropylacrylamide (NIPAM) polymer gel to record the dose distribution resulting from the mixed neutron-gamma field of boron neutron capture therapy (BNCT). In this regard, a head phantom containing NIPAM gel was irradiated using the Tehran Research Reactor BNCT beam line, and then by a magnetic resonance scanner. Eventually, the R2 maps were obtained in different slices of the phantom by analyzing T2-weighted images. The results show that NIPAM gel has a suitable potential for recording three-dimensional dose distribution in mixed neutron-gamma field dosimetry.

  12. Investigation of Dose Distribution in Mixed Neutron-Gamma Field of Boron Neutron Capture Therapy using N-Isopropylacrylamide Gel

    Directory of Open Access Journals (Sweden)

    Elham Bavarnegin

    2017-02-01

    Full Text Available Gel dosimeters have unique advantages in comparison with other dosimeters. Until now, these gels have been used in different radiotherapy techniques as a reliable dosimetric tool. Because dose distribution measurement is an important factor for appropriate treatment planning in different radiotherapy techniques, in this study, we evaluated the ability of the N-isopropylacrylamide (NIPAM polymer gel to record the dose distribution resulting from the mixed neutron-gamma field of boron neutron capture therapy (BNCT. In this regard, a head phantom containing NIPAM gel was irradiated using the Tehran Research Reactor BNCT beam line, and then by a magnetic resonance scanner. Eventually, the R2 maps were obtained in different slices of the phantom by analyzing T2-weighted images. The results show that NIPAM gel has a suitable potential for recording three-dimensional dose distribution in mixed neutron-gamma field dosimetry.

  13. Development and calculation of an energy dependent normal brain tissue neutron RBE for evaluating neutron fields for BNCT.

    Science.gov (United States)

    Woollard, J E; Blue, T E; Gupta, N; Gahbauer, R A

    2001-06-01

    In Boron Neutron Capture Therapy (BNCT) of malignant brain tumors, the energy dependence of a clinically relevant Relative Biological Effectiveness (RBE) for epithermal neutrons, RBE(En), is important in neutron field design. In the first half of this paper, we present the development of an expression for the energy dependent normal-tissue RBE, RBE(En). We then calculate a reasonable estimate for RBE(En) for adult brain tissue. In the second half of the paper, two separate RBE expressions are developed, one for the RBE of the neutrons that interact in tissue via the 14N(n,p)14C reaction, denoted RBE(N), and one for the RBE of the neutrons which interact in tissue via the 1H(n,n')1H reaction, denoted RBE(H). The absorbed-dose-averaged values of these expressions are calculated for the neutron flux spectrum in phantom for the Brookhaven Medical Research Reactor (BMRR) epithermal neutron beam. The calculated values, [RBE(norm)N] = 3.4 and [RBE(norm)H] = 3.2, are within 6% of being equal, and support the use of equal values for RBEN and RBE(H) by researchers at Brookhaven National Laboratory (BNL). Finally, values of [RBE(norm)N] and [RBE(norm)H], along with the absorbed-dose-averaged RBE for brain, [RBE(norm)b], were calculated as a function of depth along the centerline of an ellipsoidal head phantom using flux spectra calculated for our Accelerator-Based Neutron Source (ABNS). These values remained essentially constant with depth, supporting the use of constant values for RBE, as is done at BNL.

  14. Pulse shape discrimination between (fast or thermal) neutrons and gamma rays with plastic scintillators: State of the art

    Energy Technology Data Exchange (ETDEWEB)

    Bertrand, Guillaume H.V. [CEA, LIST, Laboratoire Capteurs & Architectures Électroniques, CEA Saclay, F-91191 Gif-sur-Yvette cedex (France); Hamel, Matthieu, E-mail: matthieu.hamel@cea.fr [CEA, LIST, Laboratoire Capteurs & Architectures Électroniques, CEA Saclay, F-91191 Gif-sur-Yvette cedex (France); Normand, Stéphane [CEA, DAM, Le Ponant, 25 rue Leblanc, F-75015 Paris (France); Sguerra, Fabien [CEA, LIST, Laboratoire Capteurs & Architectures Électroniques, CEA Saclay, F-91191 Gif-sur-Yvette cedex (France)

    2015-03-11

    We would like to present here with the eyes of the chemist the most recent developments of plastic scintillators (PS) for neutron detection. This review covers the period from 2000 to August 2014, and is fragmented in two main chapters. The first chapter deals with the chemical modifications for thermal neutron capture, whereas the second chapter presents the various strategies used to enhance the response to fast neutrons via pulse shape discrimination. For each chapter the theory is also explained.

  15. Neutron matter instabilities induced by strong magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Aguirre, R. [Departamento de Física, Facultad de Ciencias Exactas, Universidad Nacional de La Plata and IFLP-CCT-La Plata, CONICET (Argentina); Bauer, E., E-mail: bauer@fisica.unlp.edu.ar [Departamento de Física, Facultad de Ciencias Exactas, Universidad Nacional de La Plata and IFLP-CCT-La Plata, CONICET (Argentina)

    2013-04-10

    We study some properties of spin-polarized neutron matter in the presence of a strong magnetic field at finite temperature. Using the Skyrme model together with the Hartree–Fock approximation we obtain an energy density functional that is employed to extract the spin polarization, the effective mass and the magnetic free energy of the system. In order to find the equilibrium state, we have analyzed different global spin configurations over a wide range of matter density (0field intensity (10{sup 14} G⩽B<10{sup 19} G) and temperature (T⩽80 MeV). The outcome is that the system can be either completely spin-down polarized or partially polarized. A change in any of the (n,T,B)-variables can induce a transition from one polarization state to the other. The transition takes place in a surface in the (n,T,B)-phase space, which represents an instability of the system. We have also found a discontinuity in the internal energy associated with this change in the state of magnetization.

  16. Measurements of thermal neutron fluence in the bunker of a cyclotron for PET isotope production; Medidas de fluencia de neutrones termicos en el bunker de un ciclotron de produccion de isotopos para PET

    Energy Technology Data Exchange (ETDEWEB)

    Mendez Villafane, R.; Sansoloni florit, F.; Lagares gonzalez, J. L.; Llop Roig, J.; Guerrero Araque, J. E.; Muniz Gutierrez, J. L.; Perez Morales, J. M.

    2011-07-01

    To measure the neutron spectrum has been used spectrometry system based on Bonner spheres with Au flakes as thermal neutron detector at its center while the results are still pending and will be analyzing another job.

  17. Eigenstate Thermalization Hypothesis in Conformal Field Theory

    CERN Document Server

    Lashkari, Nima; Liu, Hong

    2016-01-01

    We investigate the eigenstate thermalization hypothesis (ETH) in d+1 dimensional conformal field theories by studying reduced density matrices in energy eigenstates. We show that if local probes of high energy primary eigenstates satisfy ETH, then any finite energy observable with support on a subsystem of finite size satisfies ETH. In two dimensions, we discover that if ETH holds locally, the finite size reduced density matrix of states created by heavy primary operators is well-approximated by a projection to the Virasoro identity block.

  18. Neutron field produced by 25 MeV deuteron on thick beryllium for radiobiological study; energy spectrum.

    Science.gov (United States)

    Takada, Masashi; Mihara, Erika; Sasaki, Michiya; Nakamura, Takashi; Honma, Toshihiko; Kono, Koji; Fujitaka, Kazunobu

    2004-01-01

    Biological data is necessary for estimation of protection from neutrons, but there is a lack of data on biological effects of neutrons for radiation protection. Radiological study on fast neutrons has been done at the National Institute of Radiological Sciences. An intense neutron source has been produced by 25 MeV deuterons on a thick beryllium target. The neutron energy spectrum, which is essential for neutron energy deposition calculation, was measured from thermal to maximum energy range by using an organic liquid scintillator and multi-sphere moderated 3He proportional counters. The spectrum of the gamma rays accompanying the neutron beam was measured simultaneously with the neutron spectrum using the organic liquid scintillator. The transmission by the shield of the spurious neutrons originating from the target was measured to be less than 1% by using the organic liquid scintillator placed behind the collimator. The measured neutron energy spectrum is useful in dose calculations for radiobiology studies.

  19. Monte Carlo simulations as a feasibility tool for non-metallic land-mine detection by thermal-neutron backscattering

    NARCIS (Netherlands)

    Maucec, M; de Meijer, RJ

    2002-01-01

    The use of Monte Carlo simulations is presented for modelling a simplified land-mine detector system with thermal neutron backscattering (TNB) analysis based on a Cf-252-neutron source. Different aspects and a variety of external conditions, related to localisation and identification of a buried obj

  20. Detection efficiency, spatial and timing resolution of thermal and cold neutron counting MCP detectors

    Science.gov (United States)

    Tremsin, A. S.; McPhate, J. B.; Vallerga, J. V.; Siegmund, O. H. W.; Hull, J. S.; Feller, W. B.; Lehmann, E.

    2009-06-01

    Neutron counting detectors with boron or gadolinium doped microchannel plates (MCPs) have very high detection efficiency, spatial and temporal resolution, and have a very low readout noise. In this paper we present the results of both theoretical predictions and experimental evaluations of detection efficiency and spatial resolution measured at cold and thermal neutron beamlines. The quantum detection efficiency of a detector (not fully optimized) was measured to be 43% and 16% for the cold and thermal beamlines, respectively. The experiments also demonstrate that the spatial resolution can be better than 15 μm—highest achievable with the particular MCP pore dimension used in the experiment, although more electronics development is required in order to increase the counting rate capabilities of those <15 μm resolution devices. The timing accuracy of neutron detection is on the scale of few μs and is limited by the neutron absorption depth in the detector. The good agreement between the predicted and measured performance allows the optimization of the detector parameters in order to achieve the highest spatial resolution and detection efficiency in future devices.

  1. The thermal neutron capture cross section of the radioactive isotope $^{60}$Fe

    CERN Document Server

    Heftrich, T; Dressler, R; Eberhardt, K; Endres, A; Glorius, J; Göbel, K; Hampel, G; Heftrich, M; Käppeler, F; Lederer, C; Mikorski, M; Plag, R; Reifarth, R; Stieghorst, C; Schmidt, S; Schumann, D; Slavkovská, Z; Sonnabend, K; Wallner, A; Weigand, M; Wiehl, N; Zauner, S

    2015-01-01

    50% of the heavy element abundances are produced via slow neutron capture reactions in different stellar scenarios. The underlying nucleosynthesis models need the input of neutron capture cross sections. One of the fundamental signatures for active nucleosynthesis in our galaxy is the observation of long-lived radioactive isotopes, such as $^{60}$Fe with a half-life of $2.60\\times10^6$ yr. To reproduce this $\\gamma$-activity in the universe, the nucleosynthesis of $^{60}$Fe has to be understood reliably. A $^{60}$Fe sample produced at the Paul-Scherrer-Institut was activated with thermal and epithermal neutrons at the research reactor at the Johannes Gutenberg-Universit\\"at Mainz. The thermal neutron capture cross section has been measured for the first time to $\\sigma_{\\text{th}}=0.226 \\ (^{+0.044}_{-0.049})$ b. An upper limit of $\\sigma_{\\text{RI}} < 0.50$ b could be determined for the resonance integral. An extrapolation towards the astrophysicaly interesting energy regime between $kT$=10 keV and 100 ke...

  2. New evaluation of thermal neutron scattering libraries for light and heavy water

    Directory of Open Access Journals (Sweden)

    Marquez Damian Jose Ignacio

    2017-01-01

    Full Text Available In order to improve the design and safety of thermal nuclear reactors and for verification of criticality safety conditions on systems with significant amount of fissile materials and water, it is necessary to perform high-precision neutron transport calculations and estimate uncertainties of the results. These calculations are based on neutron interaction data distributed in evaluated nuclear data libraries. To improve the evaluations of thermal scattering sub-libraries, we developed a set of thermal neutron scattering cross sections (scattering kernels for hydrogen bound in light water, and deuterium and oxygen bound in heavy water, in the ENDF-6 format from room temperature up to the critical temperatures of molecular liquids. The new evaluations were generated and processable with NJOY99 and also with NJOY-2012 with minor modifications (updates, and with the new version of NJOY-2016. The new TSL libraries are based on molecular dynamics simulations with GROMACS and recent experimental data, and result in an improvement of the calculation of single neutron scattering quantities. In this work, we discuss the importance of taking into account self-diffusion in liquids to accurately describe the neutron scattering at low neutron energies (quasi-elastic peak problem. To improve modeling of heavy water, it is important to take into account temperature-dependent static structure factors and apply Sköld approximation to the coherent inelastic components of the scattering matrix. The usage of the new set of scattering matrices and cross-sections improves the calculation of thermal critical systems moderated and/or reflected with light/heavy water obtained from the International Criticality Safety Benchmark Evaluation Project (ICSBEP handbook. For example, the use of the new thermal scattering library for heavy water, combined with the ROSFOND-2010 evaluation of the cross sections for deuterium, results in an improvement of the C/E ratio in 48 out of

  3. Magnetic field amplification in proto-neutron stars -- The role of the neutron-finger instability for dynamo excitation

    CERN Document Server

    Naso, L; Bonanno, A; Paternò, L

    2007-01-01

    During the first 40 s after their birth, proto-neutron stars are expected to be subject to at least two types of instability: the convective instability and the neutron-finger one. Both instabilities involve convective motions and hence can trigger dynamo actions which may be responsible for the large magnetic fields in neutron stars and magnetars. We have solved the mean-field induction equation in a simplified one-dimensional model of both the convective and the neutron-finger instability zones. Although very idealized, the model includes the nonlinearities introduced by the feedback processes which tend to saturate the growth of the magnetic field (alpha-quenching) and suppress its turbulent diffusion (eta-quenching). The possibility of a dynamo action is studied within a dynamical model of turbulent diffusivity where the boundary of the unstable zone is allowed to move. We show that the dynamo action can be operative and that the amplification of the magnetic field can still be very effective. Furthermore...

  4. Thermal neutron detector and gamma-ray spectrometer utilizing a single material

    Energy Technology Data Exchange (ETDEWEB)

    Stowe, Ashley; Burger, Arnold; Lukosi, Eric

    2017-05-02

    A combined thermal neutron detector and gamma-ray spectrometer system, including: a detection medium including a lithium chalcopyrite crystal operable for detecting thermal neutrons in a semiconductor mode and gamma-rays in a scintillator mode; and a photodetector coupled to the detection medium also operable for detecting the gamma rays. Optionally, the detection medium includes a .sup.6LiInSe.sub.2 crystal. Optionally, the detection medium comprises a compound formed by the process of: melting a Group III element; adding a Group I element to the melted Group III element at a rate that allows the Group I and Group III elements to react thereby providing a single phase I-III compound; and adding a Group VI element to the single phase I-III compound and heating; wherein the Group I element includes lithium.

  5. Performance of an improved thermal neutron activation detector for buried bulk explosives

    Energy Technology Data Exchange (ETDEWEB)

    McFee, J.E., E-mail: jemcfee@gmail.com [Defence R and D Canada – Suffield, Medicine Hat (Canada); Faust, A.A. [Defence R and D Canada – Suffield, Medicine Hat (Canada); Andrews, H.R.; Clifford, E.T.H. [Bubble Technology Industries Inc., Chalk River (Canada); Mosquera, C.M. [Defence R and D Canada – Suffield, Medicine Hat (Canada)

    2013-06-01

    First generation thermal neutron activation (TNA) sensors, employing an isotopic source and NaI(Tl) gamma ray detectors, were deployed by Canadian Forces in 2002 as confirmation sensors on multi-sensor landmine detection systems. The second generation TNA detector is being developed with a number of improvements aimed at increasing sensitivity and facilitating ease of operation. Among these are an electronic neutron generator to increase sensitivity for deeper and horizontally displaced explosives; LaBr{sub 3}(Ce) scintillators, to improve time response and energy resolution; improved thermal and electronic stability; improved sensor head geometry to minimize spatial response nonuniformity; and more robust data processing. The sensor is described, with emphasis on the improvements. Experiments to characterize the performance of the second generation TNA in detecting buried landmines and improvised explosive devices (IEDs) hidden in culverts are described. Performance results, including comparisons between the performance of the first and second generation systems are presented.

  6. A numerical model of a coated capillary-plate thermal neutron collimator

    Institute of Scientific and Technical Information of China (English)

    TIAN Yang; YANG Yi-Gang; LI Yu-Lan; LI Yuan-Jing

    2012-01-01

    A novel thermal neutron collimator was successfully fabricated by coating the inner surface of the capillary plate (CP) with gadolinium oxide using atomic layer deposition (ALD) technology.This CP-based collimator is efficient and compact.A numerical model is presented in the paper to estimate the main performance characteristics of the collimator and to optimize the design for specific applications.According to the results of the calculation based on currently available CPs,the FWHM of the collimator's rocking curve can be smaller than 0.15° while suppressing more than 99.9% of the incident thermal neutrons on the double wings of the curve.Such a coated CP is as thin as 1.25 mm or even thinner,providing high angular resolution with good transmission in a very limited space.

  7. THERMAL HYDRAULIC ANALYSIS OF A LIQUID-METAL-COOLED NEUTRON SPALLATION TARGET

    Energy Technology Data Exchange (ETDEWEB)

    W. GREGORY; R. MARTIN; T. VALACHOVIC

    2000-07-01

    We have carried out numerical simulations of the thermal hydraulic behavior of a neutron spallation target where liquid metal lead-bismuth serves as both coolant and as a neutron spallation source. The target is one of three designs provided by the Institute of Physics and Power Engineering (IPPE) in Russia. This type of target is proposed for Accelerator-driven Transmutation of Waste (ATW) to eliminate plutonium from hazardous fission products. The thermal hydraulic behavior was simulated by use of a commercial CFD computer code called CFX. Maximum temperatures in the diaphragm window and in the liquid lead were determined. In addition the total pressure drop through the target was predicted. The results of the CFX analysis were close to those results predicted by IPPE in their preliminary analysis.

  8. Thermal neutrons' flux near the Earth's surface as an evidence of the crustal stress

    Science.gov (United States)

    Sigaeva, Ekaterina; Nechayev, Oleg; Volodichev, Nikolay; Antonova, Valentina; Kryukov, Sergey; Chubenko, Alexander; Shchepetov, Alexander

    There are some ideas about the Earth’s global seismic activity appearance due to tidal forces. At the same time, the correlations between the big series of the earthquakes and the New and Full Moons and between the New and Full Moons and the increasings of the thermal neutrons’ flux from the Earth’s crust were observed. It is as though there are internal links between these three natural phenomena and the physical reasons for their appearance are the same. The paper presents the results of the ground-based thermal neutrons observations during different time periods characterized with phenomena in the near-Earth space (for instance, the New and Full Moon). Basing on the up-to-date conception of the tidal waves influence on the Earth's crust the authors confirm the role of the Moon in the production of the neutron flux near the Earth's surface.

  9. A CONCEPTUAL DESIGN OF NEUTRON COLLIMATOR IN THE THERMAL COLUMN OF KARTINI RESEARCH REACTOR FOR IN VITRO AND IN VIVO TEST OF BORON NEUTRON CAPTURE THERAPY

    OpenAIRE

    Nina Fauziah; Andang Widiharto; Yohannes Sardjono

    2015-01-01

    Studies were carried out to design a collimator which results in epithermal neutron beam for IN VITRO and IN VIVO of Boron Neutron Capture Therapy (BNCT) at the Kartini research reactor by means of Monte Carlo N-Particle (MCNP) codes. Reactor within 100 kW of thermal power was used as the neutron source. The design criteria were based on recommendation from the International Atomic Energy Agency (IAEA). All materials used were varied in size, according to the value of mean free path for each ...

  10. Analytical capabilities of the new thermal neutron prompt gamma-ray activation analysis instrument at the National Institute of Standards and Technology Center for Neutron Research

    Energy Technology Data Exchange (ETDEWEB)

    Mackey, E.A. [National Institute of Standards and Technology, Analytical Chemistry Division, Gaithersburg, MD (United States); Anderson, D.L. [US Food and Drug Administration, Elemental Research Branch, College Park, MD (United States)

    2004-07-01

    A new thermal neutron prompt gamma-ray activation analysis (PGAA) instrument was designed and built to replace the original PGAA system at the National Institute of Standards and Technology's Center for Neutron Research. The new PGAA instrument was constructed to achieve a reduction of the fast neutron beam component, a reduction of background gamma-radiation (including gamma-ray lines that directly interfere with element analyses, low-energy scattered gamma rays, and Compton scattered gamma rays), improvement in element sensitivities and limits of detection (LODs), and a simplified instrument set-up procedure. (orig.)

  11. Radiation fields from neutron generators shielded with different materials

    Science.gov (United States)

    Chichester, D. L.; Blackburn, B. W.

    2007-08-01

    As a general guide for assessing radiological conditions around a DT neutron generator numerical modeling has been performed to assess neutron and photon dose profiles for a variety of shield materials ranging from 1 to 100 cm thick. In agreement with accepted radiation safety practices high-Z materials such as bismuth and lead have been found to be ineffective biological shield materials, owing in part to the existence of (n,2n) reaction channels available with 14.1 MeV DT neutrons, while low-Z materials serve as effective shields for these sources. Composite materials such as a mixture of polyethylene and bismuth, or regular concrete, are ideal shield materials for neutron generator radiation because of their ability to attenuate internally generated photon radiation resulting from neutron scattering and capture within the shields themselves.

  12. Influence of Thermal Neutrons on Fatty Acids with a Mesomorphic Behavior

    Science.gov (United States)

    Honciuc, M.; Slavnicu, E.

    The paper describes the influence of thermal neutron irradiation on the smectic liquid crystal (SLC) properties of fatty acids: lauric, archydic, elaidic and arachidonic. These fatty acids are precursors or constituents of biological membranes. Microstructural aspects and electric measurements of the dependence of current intensity through the sample on the applied external voltage I=I(U) are presented. An outline of a thermodynamic model in good agreement with the experiments is also given.

  13. Analytical sensitivities and energies of thermal-neutron-capture gamma rays

    Science.gov (United States)

    Duffey, D.; El-Kady, A.; Senftle, F.E.

    1970-01-01

    A table of the analytical sensitivities of the principal lines in the thermal-neutron-capture gamma ray spectrum has been compiled for most of the elements. In addition a second table of the full-energy, single-escape, and double-escape peaks has been compiled according to energy for all significant lines above 3 MeV. Lines that contrast well with adjacent lines are noted as prominent. The tables are useful for spectral interpretation and calibration. ?? 1970.

  14. Analytical sensitivities and energies of thermal neutron capture gamma rays II

    Science.gov (United States)

    Senftle, F.E.; Moore, H.D.; Leep, D.B.; El-Kady, A.; Duffey, D.

    1971-01-01

    A table of the analytical sensitivities of the principal lines in the thermal neutron capture gamma-ray spectrum from 0 to 3 MeV has been compiled for most of the elements. A tabulation of the full-energy, single-escape, and double-escape peaks has also been made according to energy. The tables are useful for spectral interpretation and calibration. ?? 1971.

  15. Neutron emission effects on fragment mass and kinetic energy distribution from fission of 239Pu induced by thermal neutrons

    Science.gov (United States)

    Montoya, M.; Rojas, J.; Lobato, I.

    2010-08-01

    The average of fragment kinetic energy (E*) and the multiplicity of prompt neutrons (ν) as a function of fragment mass (m*), as well as the fragment mass yield (Y(m*)) from thermal neutron-induced fission of 239Pu have been measured by Tsuchiya et al.. In that work the mass and kinetic energy are calculated from the measured kinetic energy of one fragment and the difference of time of flight of the two complementary fragments. However they do not present their results about the standard deviation σE*(m*). In this work we have made a numerical simulation of that experiment which reproduces its results, assuming an initial distribution of the primary fragment kinetic energy (E(A)) with a constant value of the standard deviation as function of fragment mass (σE(A)). As a result of the simulation we obtain the dependence σE*(m*) which presents an enhancement between m* = 92 and m* = 110, and a peak at m* = 121.

  16. Magnetic structure determination using zero-field neutron polarimetry. [Cr-O; Cu-Ce

    Energy Technology Data Exchange (ETDEWEB)

    Nunez, V. (Inst. Laue-Langevin, 38 - Grenoble (France) Dept. of Physics, King' s Coll. London, Strand (United Kingdom)); Brown, P.J.; Tasset, F. (Inst. Laue-Langevin, 38 - Grenoble (France)); Chattopadhyay, T. (Inst. Laue-Langevin, 38 - Grenoble (France) Centre d' Etudes Nucleaires, 38 - Grenoble (France)); Forsyth, J.B. (Rutherford Appleton Lab., Chilton (United Kingdom))

    1992-06-01

    A simple interpretation of the formulae which predict the polarisation of elastically scattered neutrons and a pictorial representation of the polarisation directions before and after the scattering process are presented. Some results from recent zero-field neutron polarimetry experiments are used to demonstrate the theory. (orig.).

  17. Deficiency in Monte Carlo simulations of coupled neutron-gamma-ray fields

    NARCIS (Netherlands)

    Maleka, Peane P.; Maucec, Marko; de Meijer, Robert J.

    2011-01-01

    The deficiency in Monte Carlo simulations of coupled neutron-gamma-ray field was investigated by benchmarking two simulation codes with experimental data. Simulations showed better correspondence with the experimental data for gamma-ray transport only. In simulations, the neutron interactions with m

  18. Proton and neutron skins of light nuclei within the Relativistic Mean Field theory

    CERN Document Server

    Geng, L S; Ozawa, A; Meng, J

    2004-01-01

    The Relativistic Mean Field (RMF) theory is applied to the analysis of ground-state properties of Ne, Na, Cl and Ar isotopes. In particular, we study the recently established proton skin in Ar isotopes and neutron skin in Na isotopes as a function of the difference between the proton and the neutron separation energy. We take the TMA effective interaction in the RMF Lagrangian, and describe pairing correlation by the density-independent delta-function interaction. We calculate single neutron and proton separation energies, quadrupole deformations, nuclear matter radii, and differences in proton radii and neutron radii, and compare these results with the recent experimental data.

  19. A CONCEPTUAL DESIGN OF NEUTRON COLLIMATOR IN THE THERMAL COLUMN OF KARTINI RESEARCH REACTOR FOR IN VITRO AND IN VIVO TEST OF BORON NEUTRON CAPTURE THERAPY

    Directory of Open Access Journals (Sweden)

    Nina Fauziah

    2015-03-01

    Full Text Available Studies were carried out to design a collimator which results in epithermal neutron beam for IN VITRO and IN VIVO of Boron Neutron Capture Therapy (BNCT at the Kartini research reactor by means of Monte Carlo N-Particle (MCNP codes. Reactor within 100 kW of thermal power was used as the neutron source. The design criteria were based on recommendation from the International Atomic Energy Agency (IAEA. All materials used were varied in size, according to the value of mean free path for each material. MCNP simulations indicated that by using 5 cm thick of Ni as collimator wall, 60 cm thick of Al as moderator, 15 cm thick of 60Ni as filter, 2 cm thick of Bi as γ-ray shielding, 3 cm thick of 6Li2CO3-polyethylene as beam delimiter, with 1 to 5 cm varied aperture size, epithermal neutron beam with maximum flux of 7.65 x 108 n.cm-2.s-1 could be produced. The beam has minimum fast neutron and γ-ray components of, respectively, 1.76 x 10-13 Gy.cm2.n-1 and 1.32 x 10-13 Gy.cm2.n-1, minimum thermal neutron per epithermal neutron ratio of 0.008, and maximum directionality of 0.73. It did not fully pass the IAEA’s criteria, since the epithermal neutron flux was below the recommended value, 1.0 x 109 n.cm-2.s-1. Nonetheless, it was still usable with epithermal neutron flux exceeding 5.0 x 108 n.cm-2.s-1. When it was assumed that the graphite inside the thermal column was not discharged but only the part which was going to be replaced by the collimator, the performance of the collimator became better within the positive effect from the surrounding graphite that the beam resulted passed all criteria with epithermal neutron flux up to 1.68 x 109 n.cm-2.s-1. Keywords: design, collimator, epithermal neutron beam, BNCT, MCNP, criteria   Telah dilakukan penelitian tentang desain kolimator yang menghasilkan radiasi netron epitermal untuk uji in vitro dan in vivo pada Boron Neutron Capture Therapy (BNCT di Reaktor Riset Kartini dengan menggunakan program Monte

  20. Evaluation of Silicon Neutron Resonance Parameters in the Energy Range Thermal to 1800 keV

    Energy Technology Data Exchange (ETDEWEB)

    Derrien, H.

    2002-09-30

    The evaluation of the neutron cross sections of the three stable isotopes of silicon in the energy range thermal to 20 MeV was performed by Hetrick et al. for ENDF/B-VI (Evaluated Nuclear Data File). Resonance parameters were obtained in the energy range thermal to 1500 keV from a SAMMY analysis of the Oak Ridge National Laboratory experimental neutron transmission data. A new measurement of the capture cross section of natural silicon in the energy range 1 to 700 keV has recently been performed at the Oak Ridge Electron Linear Accelerator. Results of this measurement were used in a SAMMY reevaluation of the resonance parameters, allowing determination of the capture width of a large number of resonances. The experimental data base is described; properties of the resonance parameters are given. For the first time the direct neutron capture component has been taken into account from the calculation by Rauscher et al. in the energy range from thermal to 1 MeV. Results of benchmark calculations are also given. The new evaluation is available in the ENDF/B-VI format.

  1. Thermal neutron response and theoretical comparison of LiF coated aluminized Mylar

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Kyle A., E-mail: knelson1@ksu.edu; Bellinger, Steven L.; Edwards, Nathaniel S.; Montag, Benjamin W.; Schmidt, Aaron J.; Wayant, Clayton; McGregor, Douglas S.

    2014-10-21

    Thin layers of LiF were deposited on a 2.0 µm thick aluminized BoPET (i.e. Mylar) in thicknesses of 4.5, 9.9, and 14.0 µm using an electron beam evaporator. These coatings were thinner than the summed triton and alpha particle range from the {sup 6}Li(n,t){sup 4}He reaction, which allows both particles to escape a suspended absorber sheet simultaneously and measured in a proportional gas region concurrently. Each thickness of the LiF coated Mylar sheets were positioned separately in a test chamber that had a single anode wire positioned on each side of the absorber sheets. The thermal neutron response pulse-height spectra were collected for each LiF thickness and are presented and discussed. The coatings became fragile at thicknesses greater than 5.0 µm and would flake off of the Mylar sheets. Additionally, the ideal LiF coating thickness that maximizes the intrinsic thermal neutron detection efficiency is greater than 5.0 µm, which is discussed in a greater detail in the text. Overall, the detectors are capable of achieving thermal-neutron detection efficiencies greater than 30% for a 5 layer device and 60 % for 20 layers, but these devices are complex to fabricate due to flaking of the LiF coatings. Additional research is required to eliminate flaking by possibly using additional mechanical structures or adhesive materials.

  2. Limits on thermal variations in a dozen quiescent neutron stars over a decade

    CERN Document Server

    Bahramian, Arash; Degenaar, Nathalie; Chomiuk, Laura; Wijnands, Rudy; Strader, Jay; Ho, Wynn C G; Pooley, David

    2015-01-01

    In quiescent low-mass X-ray binaries (qLMXBs) containing neutron stars, the origin of the thermal X-ray component may be either release of heat from the core of the neutron star, or continuing low-level accretion. In general, heat from the core should be stable on timescales $<10^4$ years, while continuing accretion may produce variations on a range of timescales. While some quiescent neutron stars (e.g. Cen X-4, Aql X-1) have shown variations in their thermal components on a range of timescales, several others, particularly those in globular clusters with no detectable nonthermal hard X-rays (fit with a powerlaw), have shown no measurable variations. Here, we constrain the spectral variations of 12 low mass X-ray binaries in 3 globular clusters over $\\sim10$ years. We find no evidence of variations in 10 cases, with limits on temperature variations below 11% for the 7 qLMXBs without powerlaw components, and limits on variations below 20% for 3 other qLMXBs that do show non-thermal emission. However, in 2 ...

  3. The study of physics and thermal characteristics for in-hospital neutron irradiator (IHNI).

    Science.gov (United States)

    Ke, Guotu; Sun, Ziyong; Shen, Feng; Liu, Tiancai; Li, Yiguo; Zhou, Yongmao

    2009-07-01

    The IHNI is designed for boron neutron capture therapy (BNCT) based on miniature neutron source reactor (MNSR). The reactor with thermal power 30 kW is an undermoderated reactor of pool-tank type, and UO(2) as fuel, light water as coolant and moderator, and metallic beryllium as reflector. The fission heat produced by the reactor is removed by the natural convection. The paper gives the calculating results of critical mass and the worths of central control rod, auxiliary control rod, reactivity regulator and neutron beam equipments. The parameters at thermal and small thermal ports and at epithermal port were calculated by optimizing combination of kinds of material by MCNP code. The dynamic feature research was done by RELAP5 code when the reactivities of 3, 4.5 and 6 mK were inserted, respectively. The results show that the reactor power can be limited to safe level by itself owing to the Doppler effect of fuel element and moderator negative temperature effect when the 6 mK reactivity was inserted into the reactor.

  4. Frame Dragging Effect on Properties of Rotating Neutron Stars with Strong Magnetic Field

    Institute of Scientific and Technical Information of China (English)

    GUO Yu-Wu; WEN De-Hua; HU Jian-Xun

    2008-01-01

    The general relativistic frame dragging effect on the properties, such as the moments of inertia and the radii of gyration of fast rotating neutron stars with a uniform strong magnetic field, is calculated accurate to the first order in the uniform angular velocity. The results show that compared with the corresponding non-rotating static spherical symmetric neutron star with a weaker magnetic field, a fast rotating neutron star (millisecond pulsar) with a stronger magnetic field has a relative smaller moment of inertia and radius of gyration.

  5. Quantification of the sensitivity range in neutron dark-field imaging

    Energy Technology Data Exchange (ETDEWEB)

    Betz, B.; Harti, R. P.; Hovind, J.; Kaestner, A.; Lehmann, E.; Grünzweig, C. [Paul Scherrer Institute, LNS, Neutron Imaging and Activation Group, CH-5232 Villigen (Switzerland); Strobl, M. [European Spallation Source ESS, 22100 Lund, Sweden and University of Copenhagen, 2100 Copenhagen (Denmark); Van Swygenhoven, H. [Ecole Polytechnique Fédérale de Lausanne, NXMM Laboratory, IMX, CH-1015 Lausanne, Switzerland and Paul Scherrer Institut, NXMM, CH-5232 Villigen (Switzerland)

    2015-12-15

    In neutron grating interferometry, the dark-field image visualizes the scattering properties of samples in the small-angle and ultra-small-angle scattering range. These angles correspond to correlation lengths from several hundred nanometers up to several tens of micrometers. In this article, we present an experimental study that demonstrates the potential of quantitative neutron dark-field imaging. The dark-field signal for scattering from different particle sizes and concentrations of mono-dispersive polystyrene particles in aqueous solution is compared to theoretical predictions and the good agreement between measurements and calculations underlines the quantitative nature of the measured values and reliability of the technique with neutrons.

  6. Feasibility study for creating spectrum changeable neutron calibration fields. Objective and test simulations of spectra for conceptual design

    Energy Technology Data Exchange (ETDEWEB)

    Saegusa, Jun; Tanimura, Yoshihiko; Yoshizawa, Michio; Yoshida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-03-01

    Feasibility studies were made toward the built of the spectrum changeable neutron calibration fields with the Van-de-Graff accelerator in the Facility of Radiation Standards (FRS) in JAERI. The neutron fields are planed to have various energy spectra to calibrate neutron dosemeters under similar conditions to those in actual workplaces. The objectives and concepts of the fields are discussed, followed by the test simulation results of neutron spectra produced by simple arrangements of a target and moderators. (author)

  7. Skyrme model study of proton and neutron properties in a strong magnetic field

    Science.gov (United States)

    He, Bing-Ran

    2017-02-01

    The proton and neutron properties in a uniform magnetic field are investigated. The Gell-Mann-Nishijima formula is shown to be satisfied for baryon states. It is found that with increasing magnetic field strength, the proton mass first decreases and then increases, while the neutron mass always increases. The ratio between magnetic moment of proton and neutron increases with the increase of the magnetic field strength. With increasing magnetic field strength, the size of proton first increases and then decreases, while the size of neutron always decreases. The present analysis implies that in the core part of the magnetar, the equation of state depend on the magnetic field, which modifies the mass limit of the magnetar.

  8. Skyrme model study of proton and neutron properties in a strong magnetic field

    CERN Document Server

    He, Bing-Ran

    2016-01-01

    The proton and neutron properties in a uniform magnetic field are investigated. The Gell-Mann-Nishijima formula is shown to be satisfied for baryon states. It is found that with increasing magnetic field strength, the proton mass first decreases and then increases, while the neutron mass always increases. The ratio between magnetic moment of proton and neutron increases with the increase of the magnetic field strength. With increasing magnetic field strength, the size of proton first increases and then decreases, while the size of neutron always decreases. The present analyse implies that in the core part of the magnetar, the equation of state depend on the magnetic field, which modifies the mass limit of the magnetar.

  9. Neutron Star Structure in the Presence of Conformally Coupled Scalar Fields

    Science.gov (United States)

    Sultana, Joseph; Bose, Benjamin; Kazanas, Demosthenes

    2014-01-01

    Neutron star models are studied in the context of scalar-tensor theories of gravity in the presence of a conformally coupled scalar field, using two different numerical equations of state (EoS) representing different degrees of stiffness. In both cases we obtain a complete solution by matching the interior numerical solution of the coupled Einstein-scalar field hydrostatic equations, with an exact metric on the surface of the star. These are then used to find the effect of the scalar field and its coupling to geometry, on the neutron star structure, particularly the maximum neutron star mass and radius. We show that in the presence of a conformally coupled scalar field, neutron stars are less dense and have smaller masses and radii than their counterparts in the minimally coupled case, and the effect increases with the magnitude of the scalar field at the center of the star.

  10. Radiation injury of boron neutron capture therapy using mixed epithermal- and thermal neutron beams in patients with malignant glioma

    Energy Technology Data Exchange (ETDEWEB)

    Kageji, T. E-mail: kageji@clin.med.tokushima-u.ac.jp; Nagahiro, S.; Mizobuchi, Y.; Toi, H.; Nakagawa, Y.; Kumada, H

    2004-11-01

    The purpose of this study was to clarify the radiation injury in acute or delayed stage after boron neutron capture therapy (BNCT) using mixed epithermal- and thermal neutron beams in patients with malignant glioma. Eighteen patients with malignant glioma underwent mixed epithermal- and thermal neutron beam and sodium borocaptate between 1998 and 2004. The radiation dose (i.e. physical dose of boron n-alpha reaction) in the protocol used between 1998 and 2000 (Protocol A, n=8) prescribed a maximum tumor volume dose of 15 Gy. In 2001, a new dose-escalated protocol was introduced (Protocol B, n=4); it prescribes a minimum tumor volume dose of 18 Gy or, alternatively, a minimum target volume dose of 15 Gy. Since 2002, the radiation dose was reduced to 80-90% dose of Protocol B because of acute radiation injury. A new Protocol was applied to 6 glioblastoma patients (Protocol C, n=6). The average values of the maximum vascular dose of brain surface in Protocol A, B and C were 11.4{+-}4.2 Gy, 15.7{+-}1.2 and 13.9{+-}3.6 Gy, respectively. Acute radiation injury such as a generalized convulsion within 1 week after BNCT was recognized in three patients of Protocol B. Delayed radiation injury such as a neurological deterioration appeared 3-6 months after BNCT, and it was recognized in 1 patient in Protocol A, 5 patients in Protocol B. According to acute radiation injury, the maximum vascular dose was 15.8{+-}1.3 Gy in positive and was 12.6{+-}4.3 Gy in negative. There was no significant difference between them. According to the delayed radiation injury, the maximum vascular dose was 13.8{+-}3.8 Gy in positive and was 13.6{+-}4.9 Gy in negative. There was no significant difference between them. The dose escalation is limited because most patients in Protocol B suffered from acute radiation injury. We conclude that the maximum vascular dose does not exceed over 12 Gy to avoid the delayed radiation injury, especially, it should be limited under 10 Gy in the case that tumor

  11. Auxiliary-field quantum Monte Carlo simulations of neutron matter in chiral effective field theory.

    Science.gov (United States)

    Wlazłowski, G; Holt, J W; Moroz, S; Bulgac, A; Roche, K J

    2014-10-31

    We present variational Monte Carlo calculations of the neutron matter equation of state using chiral nuclear forces. The ground-state wave function of neutron matter, containing nonperturbative many-body correlations, is obtained from auxiliary-field quantum Monte Carlo simulations of up to about 340 neutrons interacting on a 10(3) discretized lattice. The evolution Hamiltonian is chosen to be attractive and spin independent in order to avoid the fermion sign problem and is constructed to best reproduce broad features of the chiral nuclear force. This is facilitated by choosing a lattice spacing of 1.5 fm, corresponding to a momentum-space cutoff of Λ=414  MeV/c, a resolution scale at which strongly repulsive features of nuclear two-body forces are suppressed. Differences between the evolution potential and the full chiral nuclear interaction (Entem and Machleidt Λ=414  MeV [L. Coraggio et al., Phys. Rev. C 87, 014322 (2013).

  12. Thermal-to-fusion neutron convertor and Monte Carlo coupled simulation of deuteron/triton transport and secondary products generation

    Science.gov (United States)

    Wang, Guan-bo; Liu, Han-gang; Wang, Kan; Yang, Xin; Feng, Qi-jie

    2012-09-01

    Thermal-to-fusion neutron convertor has being studied in China Academy of Engineering Physics (CAEP). Current Monte Carlo codes, such as MCNP and GEANT, are inadequate when applied in this multi-step reactions problems. A Monte Carlo tool RSMC (Reaction Sequence Monte Carlo) has been developed to simulate such coupled problem, from neutron absorption, to charged particle ionization and secondary neutron generation. "Forced particle production" variance reduction technique has been implemented to improve the calculation speed distinctly by making deuteron/triton induced secondary product plays a major role. Nuclear data is handled from ENDF or TENDL, and stopping power from SRIM, which described better for low energy deuteron/triton interactions. As a validation, accelerator driven mono-energy 14 MeV fusion neutron source is employed, which has been deeply studied and includes deuteron transport and secondary neutron generation. Various parameters, including fusion neutron angle distribution, average neutron energy at different emission directions, differential and integral energy distributions, are calculated with our tool and traditional deterministic method as references. As a result, we present the calculation results of convertor with RSMC, including conversion ratio of 1 mm 6LiD with a typical thermal neutron (Maxwell spectrum) incidence, and fusion neutron spectrum, which will be used for our experiment.

  13. Accuracy of the thermal neutron absorption cross section measurements (based on examples of selected pulsed beam methods); Dokladnosc pomiarow przekroju czynnego absorpcji neutronow termicznych (na przykladzie wybranych metod impulsowych)

    Energy Technology Data Exchange (ETDEWEB)

    Krynicka, E. [The H. Niewodniczanski Inst. of Nuclear Physics, Cracow (Poland)

    1997-12-31

    The problem of accuracy of the thermal neutron macroscopic absorption cross section determination is discussed on examples of selected measurement methods which use non-stationary neutron fields. The computer simulation method elaborated by the author is presented as a procedure for estimating the standard deviation of the measured absorption cross section. The computer simulation method presented can be easily utilized to estimate the accuracy of measurement of various physical magnitudes. (author) 46 refs, 3 figs, 1 tab

  14. Thermal field theories and shifted boundary conditions

    CERN Document Server

    Giusti, Leonardo

    2013-01-01

    The analytic continuation to an imaginary velocity of the canonical partition function of a thermal system expressed in a moving frame has a natural implementation in the Euclidean path-integral formulation in terms of shifted boundary conditions. The Poincare' invariance underlying a relativistic theory implies a dependence of the free-energy on the compact length L_0 and the shift xi only through the combination beta=L_0(1+xi^2)^(1/2). This in turn implies that the energy and the momentum distributions of the thermal theory are related, a fact which is encoded in a set of Ward identities among the correlators of the energy-momentum tensor. The latter have interesting applications in lattice field theory: they offer novel ways to compute thermodynamic potentials, and a set of identities to renormalize non-perturbatively the energy-momentum tensor. At fixed bare parameters the shifted boundary conditions also provide a simple method to vary the temperature in much smaller steps than with the standard procedur...

  15. Beryllium, zinc and lead single crystals as a thermal neutron monochromators

    Energy Technology Data Exchange (ETDEWEB)

    Adib, M.; Habib, N. [Reactor Physics Department, NRC, Atomic Energy Authority, Cairo (Egypt); Bashter, I.I. [Physics Department, Faculty of Science, Zagazig University (Egypt); Morcos, H.N.; El-Mesiry, M.S. [Reactor Physics Department, NRC, Atomic Energy Authority, Cairo (Egypt); Mansy, M.S., E-mail: drmohamedmansy88@hotmail.com [Physics Department, Faculty of Science, Zagazig University (Egypt)

    2015-03-15

    Highlights: •Monochromatic features of Be, Zn and Pb single crystals. •Calculations of neutron reflectivity using a computer program MONO. •Optimum mosaic spread, thickness and cutting plane of single crystals. -- Abstract: The monochromatic features of Be, Zn and Pb single crystals are discussed in terms of orientation, mosaic spread, and thickness within the wavelength band from 0.04 up to 0.5 nm. A computer program MONO written in “FORTRAN-77”, has been adapted to carry out the required calculations. Calculations show that a 5 mm thick of beryllium (HCP structure) single crystal cut along its (0 0 2) plane having 0.6° FWHM are the optimum parameters when it is used as a monochromator with high reflected neutron intensity from a thermal neutron flux. Furthermore, at wavelengths shorter than 0.16 nm it is free from the accompanying higher order ones. Zinc (HCP structure) has the same parameters, with intensity much less than the latter. The same features are seen with lead (FCC structure) cut along its (3 1 1) plane with less reflectivity than the former. However, Pb (3 1 1) is more preferable than others at neutron wavelengths ⩽ 0.1 nm, since the glancing angle (θ ∼ 20°) is more suitable to carry out diffraction experiments. For a cold neutron flux, the first-order neutrons reflected from beryllium is free from the higher orders up to 0.36 nm. While for Zn single crystal is up to 0.5 nm.

  16. Measurement of Neutron Field Characteristics at Nuclear-Physics Instalations for Personal Radiation Monitoring

    CERN Document Server

    Alekseev, A G; Britvich, G I; Kosyanenko, E V; Pikalov, V A; Gomonov, I P

    2003-01-01

    n this work the observed data of neutron spectra on Rostov NEP, Kursk NEP and Smolensk NEP and on the reactor IRT MIPHI are submitted. For measurement of neutron spectra two types of spectrometer were used: SHANS (IHEP design ) and SDN-MS01 (FEI design). The comparison of the data measurements per-formed by those spectrometers above one-type cells on the reactor RBMK is submitted. On the basis of the 1-st horizontal experimental channel HEC-1 of the IRT reactor 4 reference fields of neutrons are investigated. It is shown, that spectra of neutrons of reference fields can be used for imitation of neutron spectra for conditions of NEP with VVER and RBMK type reactors.

  17. A high-field adiabatic fast passage ultracold neutron spin flipper for the UCNA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Holley, A. T.; Pattie, R. W.; Young, A. R. [Department of Physics, North Carolina State University, Raleigh, North Carolina 27695 (United States); Broussard, L. J. [Department of Physics, Duke University, Durham, North Carolina 27708 (United States); Davis, J. L.; Ito, T. M.; Lyles, J. T. M.; Makela, M.; Morris, C. L.; Mortensen, R.; Saunders, A. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Hickerson, K.; Mendenhall, M. P. [W. K. Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, California 91125 (United States); Liu, C.-Y. [Department of Physics, Indiana University, Bloomington, Indiana 47405 (United States); Mammei, R. R. [Department of Physics, Virginia Tech, Blacksburg, Virginia 24061 (United States); Rios, R. [Department of Physics, Idaho State University, Pocatello, Idaho 83209 (United States)

    2012-07-15

    The UCNA collaboration is making a precision measurement of the {beta} asymmetry (A) in free neutron decay using polarized ultracold neutrons (UCN). A critical component of this experiment is an adiabatic fast passage neutron spin flipper capable of efficient operation in ambient magnetic fields on the order of 1 T. The requirement that it operate in a high field necessitated the construction of a free neutron spin flipper based, for the first time, on a birdcage resonator. The design, construction, and initial testing of this spin flipper prior to its use in the first measurement of A with UCN during the 2007 run cycle of the Los Alamos Neutron Science Center's 800 MeV proton accelerator is detailed. These studies determined the flipping efficiency of the device, averaged over the UCN spectrum present at the location of the spin flipper, to be {epsilon}=0.9985(4).

  18. The influence of Strong Magnetic Field in Hyperonic Neutron Stars

    CERN Document Server

    Lopes, Luiz L

    2013-01-01

    The physics of neutron stars leads historically towards Landau's speculation. Even before the discovery of the neutron, he postulated the possible existence of stars more compact than white dwarfs, containing matter of the order of nuclear density. From a modern point of view neutron stars are compact objects maintained by the equilibrium between gravity and the degeneracy pressure of the fermions together with a strong nuclear repulsion force due to the high density reached in their interior. While the physics in the vicinity of nuclear saturation density is well know from phenomenology, the physics of ultra-dense nuclear matter is still an open puzzle. In this work we study dense nuclear matter within a relativistic model, allowing hyperons to be present through beta equilibrium. The presence of hyperons is justifiable since the constituents of neutron stars are fermions. So, according to the Pauli principle, as the baryon density increases, so do the Fermi momentum and the Fermi energy. On the other hand, ...

  19. Hexagonal boron nitride thin film thermal neutron detectors with high energy resolution of the reaction products

    Energy Technology Data Exchange (ETDEWEB)

    Doan, T.C.; Majety, S.; Grenadier, S.; Li, J.; Lin, J.Y.; Jiang, H.X., E-mail: hx.jiang@ttu.edu

    2015-05-21

    Hexagonal boron nitride (h-BN) is highly promising for solid-state thermal neutron detector applications due to its many outstanding physical properties, especially its very large thermal neutron capture cross-section (~3840 barns for {sup 10}B), which is several orders of magnitude larger than those of most other isotopes. The focus of the present work is to carry out studies on h-BN thin film and detector properties to lay the foundation for the development of a direct-conversion solid-state thermal neutron detector with high sensitivity. The measured carrier mobility-lifetime (μτ) product of h-BN thin films grown on sapphire substrates is 2.83×10{sup −7} cm{sup 2}/V for electrons and holes, which is comparable to the value of about 10{sup −7} cm{sup 2}/V for GaN thin films grown on sapphire. Detectors based on h-BN thin films were fabricated and the nuclear reaction product pulse height spectra were measured. Under a bias of 20 V, very narrow individual peaks corresponding to the reaction product energies of α and Li particles as well as the sum peaks have been clearly resolved in the pulse height spectrum for the first time by a B-based direct-conversion semiconductor neutron detector. Our results indicate that h-BN thin film detectors possess unique advantages including small size, low weight, portability, low voltage operation and high energy resolution of specific reaction products.

  20. Comments on cold neutron confinement by an electromagnetic classical field

    Energy Technology Data Exchange (ETDEWEB)

    Bruce, S [University of Concepcion, P O Box 160-C, Concepcion (Chile)

    2007-02-15

    Regarding a recent paper (Bruce S 2006 Phys. Scr. 74 371), we comment on cold neutron confining in a system consisting of an Aharonov-Casher together with a properly set Aharonov-Bohm configuration. We find that, for the supersymmetric ground state, an extra spin-orbit (spin-electromagnetic angular momentum density) term should be present. This effect turns out to modify the phenomenology associated with the anomalous magnetic moment of the neutron.

  1. Spin polarization phenomena in dense neutron matter at a strong magnetic field

    CERN Document Server

    Isayev, A A

    2010-01-01

    Spin polarized states in neutron matter at strong magnetic fields up to $10^{18}$ G are considered in the model with the Skyrme effective interaction. Analyzing the self-consistent equations at zero temperature, it is shown that a thermodynamically stable branch of solutions for the spin polarization parameter as a function of density corresponds to the negative spin polarization when the majority of neutron spins are oriented oppositely to the direction of the magnetic field. Besides, it is found that in a strong magnetic field the state with the positive spin polarization can be realized as a metastable state at the high density region in neutron matter. At finite temperature, the entropy of the thermodynamically stable branch demonstrates the unusual behavior being larger than that for the nonpolarized state (at vanishing magnetic field) above certain critical density which is caused by the dependence of the entropy on the effective masses of neutrons in a spin polarized state.

  2. Hall Equilibria: Solutions with toroidal and poloidal magnetic fields in Neutron Star Crusts

    CERN Document Server

    Gourgouliatos, K N; Lyutikov, M; Reisenegger, A

    2013-01-01

    We present Hall equilibrium solutions for neutron stars crusts containing toroidal and poloidal magnetic field. Some simple cases are solved analytically while more complicated configurations are found numerically through a Gauss-Seidel elliptic partial differential equation solver.

  3. Exploration of Adiabatic Resonance Crossing Through Neutron Activator Design for Thermal and Epithermal Neutron Formation in (99)Mo Production and BNCT Applications.

    Science.gov (United States)

    Khorshidi, Abdollah

    2015-10-01

    A feasibility study was performed to design thermal and epithermal neutron sources for radioisotope production and boron neutron capture therapy (BNCT) by moderating fast neutrons. The neutrons were emitted from the reaction between (9)Be, (181)Ta, and (184)W targets and 30 MeV protons accelerated by a small cyclotron at 300 μA. In this study, the adiabatic resonance crossing (ARC) method was investigated by means of (207)Pb and (208)Pb moderators, graphite reflector, and boron absorber around the moderator region. Thermal/epithermal flux, energy, and cross section of accumulated neutrons in the activator were examined through diverse thicknesses of the specified regions. Simulation results revealed that the (181)Ta target had the highest neutron yield, and also tungsten was found to have the highest values in both surface and volumetric flux ratio. Transmutation in the (98)Mo sample through radiative capture was investigated for the natural lead moderator. When the sample radial distance from the target was increased inside the graphite region, the production yield had the greatest value of activity. The potential of the ARC method is a replacement or complements the current reactor-based supply sources of BNCT purposes.

  4. Design and construction of a thermal neutron beam for BNCT at Tehran Research Reactor.

    Science.gov (United States)

    Kasesaz, Yaser; Khalafi, Hossein; Rahmani, Faezeh; Ezzati, Arsalan; Keyvani, Mehdi; Hossnirokh, Ashkan; Shamami, Mehrdad Azizi; Amini, Sepideh

    2014-12-01

    An irradiation facility has been designed and constructed at Tehran Research Reactor (TRR) for the treatment of shallow tumors using Boron Neutron Capture Therapy (BNCT). TRR has a thermal column which is about 3m in length with a wide square cross section of 1.2×1.2m(2). This facility is filled with removable graphite blocks. The aim of this work is to perform the necessary modifications in the thermal column structure to meet thermal BNCT beam criteria recommended by International Atomic Energy Agency. The main modifications consist of rearranging graphite blocks and reducing the gamma dose rate at the beam exit. Activation foils and TLD700 dosimeter have been used to measure in-air characteristics of the neutron beam. According to the measurements, a thermal flux is 5.6×10(8) (ncm(-2)s(-1)), a cadmium ratio is 186 for gold foils and a gamma dose rate is 0.57Gy h(-1).

  5. UCN sources at external beams of thermal neutrons. An example of PIK reactor

    CERN Document Server

    Lychagin, E V; Muzychka, A Yu; Nekhaev, G V; Nesvizhevsky, V V; Onegin, M S; Sharapov, E I; Strelkov, A V

    2015-01-01

    We consider ultracold neutron (UCN) sources based on a new method of UCN production in superfluid helium (4He). The PIK reactor is chosen as a perspective example of the application of this idea, which consists of installing a 4He UCN source in a beam of thermal or cold neutrons and surrounding the source with a moderator-reflector, which plays the role of a source of cold neutrons (CNs) feeding the UCN source. The CN flux in the source can be several times larger than the incident flux, due to multiple neutron reflections from the moderator-reflector. We show that such a source at the PIK reactor would provide an order of magnitude larger density and production rate than an analogous source at the ILL reactor. We estimate parameters of a 4He source with solid methane (CH4) or/and liquid deuterium (D2) moderator-reflector. We show that such a source with CH4 moderator-reflector at the PIK reactor would provide the UCN density of ~1x10^5 1/cm^3, and the UCN production rate of ~2x10^7 1/s. These values are resp...

  6. Benchmarking a first-principles thermal neutron scattering law for water ice with a diffusion experiment

    Science.gov (United States)

    Holmes, Jesse; Zerkle, Michael; Heinrichs, David

    2017-09-01

    The neutron scattering properties of water ice are of interest to the nuclear criticality safety community for the transport and storage of nuclear materials in cold environments. The common hexagonal phase ice Ih has locally ordered, but globally disordered, H2O molecular orientations. A 96-molecule supercell is modeled using the VASP ab initio density functional theory code and PHONON lattice dynamics code to calculate the phonon vibrational spectra of H and O in ice Ih. These spectra are supplied to the LEAPR module of the NJOY2012 nuclear data processing code to generate thermal neutron scattering laws for H and O in ice Ih in the incoherent approximation. The predicted vibrational spectra are optimized to be representative of the globally averaged ice Ih structure by comparing theoretically calculated and experimentally measured total cross sections and inelastic neutron scattering spectra. The resulting scattering kernel is then supplied to the MC21 Monte Carlo transport code to calculate time eigenvalues for the fundamental mode decay in ice cylinders at various temperatures. Results are compared to experimental flux decay measurements for a pulsed-neutron die-away diffusion benchmark.

  7. Event-by-event study of neutron observables in spontaneous and thermal fission

    Energy Technology Data Exchange (ETDEWEB)

    Vogt, R; Randrup, J

    2011-09-14

    The event-by-event fission model FREYA is extended to spontaneous fission of actinides and a variety of neutron observables are studied for spontaneous fission and fission induced by thermal neutrons with a view towards possible applications for SNM detection. We have shown that event-by-event models of fission, such as FREYA, provide a powerful tool for studying fission neutron correlations. Our results demonstrate that these correlations are significant and exhibit a dependence on the fissioning nucleus. Since our method is phenomenological in nature, good input data are especially important. Some of the measurements employed in FREYA are rather old and statistics limited. It would be useful to repeat some of these studies with modern detector techniques. In addition, most experiments made to date have not made simultaneous measurements of the fission products and the prompt observables, such as neutron and photons. Such data, while obviously more challenging to obtain, would be valuable for achieving a more complete understanding of the fission process.

  8. Empirically testing vaterite structural models using neutron diffraction and thermal analysis

    Science.gov (United States)

    Chakoumakos, Bryan C.; Pracheil, Brenda M.; Koenigs, Ryan P.; Bruch, Ronald M.; Feygenson, Mikhail

    2016-11-01

    Otoliths, calcium carbonate (CaCO3) ear bones, are among the most commonly used age and growth structures of fishes. Most fish otoliths are comprised of the most dense CaCO3 polymorph, aragonite. Sturgeon otoliths, in contrast, have been characterized as the rare and structurally enigmatic polymorph, vaterite—a metastable polymorph of CaCO3. Vaterite is an important material ranging from biomedical to personal care applications although its crystal structure is highly debated. We characterized the structure of Lake Sturgeon otoliths using thermal analysis and neutron powder diffraction, which is used non-destructively. We confirmed that while Lake Sturgeon otoliths are primarily composed of vaterite, they also contain the denser CaCO3 polymorph, calcite. For the vaterite fraction, neutron diffraction data provide enhanced discrimination of the carbonate group compared to x-ray diffraction data, owing to the different relative neutron scattering lengths, and thus offer the opportunity to uniquely test the more than one dozen crystal structural models that have been proposed for vaterite. Of those, space group P6522 model, a = 7.1443(4)Å, c = 25.350(4)Å, V = 1121.5(2)Å3 provides the best fit to the neutron powder diffraction data, and allows for a structure refinement using rigid carbonate groups.

  9. Empirically testing vaterite structural models using neutron diffraction and thermal analysis.

    Science.gov (United States)

    Chakoumakos, Bryan C; Pracheil, Brenda M; Koenigs, Ryan P; Bruch, Ronald M; Feygenson, Mikhail

    2016-11-18

    Otoliths, calcium carbonate (CaCO3) ear bones, are among the most commonly used age and growth structures of fishes. Most fish otoliths are comprised of the most dense CaCO3 polymorph, aragonite. Sturgeon otoliths, in contrast, have been characterized as the rare and structurally enigmatic polymorph, vaterite-a metastable polymorph of CaCO3. Vaterite is an important material ranging from biomedical to personal care applications although its crystal structure is highly debated. We characterized the structure of Lake Sturgeon otoliths using thermal analysis and neutron powder diffraction, which is used non-destructively. We confirmed that while Lake Sturgeon otoliths are primarily composed of vaterite, they also contain the denser CaCO3 polymorph, calcite. For the vaterite fraction, neutron diffraction data provide enhanced discrimination of the carbonate group compared to x-ray diffraction data, owing to the different relative neutron scattering lengths, and thus offer the opportunity to uniquely test the more than one dozen crystal structural models that have been proposed for vaterite. Of those, space group P6522 model, a = 7.1443(4)Å, c = 25.350(4)Å, V = 1121.5(2)Å(3) provides the best fit to the neutron powder diffraction data, and allows for a structure refinement using rigid carbonate groups.

  10. A unique focusing property of a parabolic mirror for neutrons in the gravitational field: geometric proof

    CERN Document Server

    Masalovich, S

    2014-01-01

    An extraordinary focusing property of a parabolic mirror for ultracold neutrons in the presence of the gravitational field was first reported by A. Steyerl and co-authors. It was shown that all neutrons emitted from the focus of the mirror will be reflected back upon the same focus point passing, in between, a point of return in the gravitational field. The present note offers a complementary geometric proof of this feature and discusses some implications.

  11. A magnetic trap for high-field seeking neutron spin states

    Directory of Open Access Journals (Sweden)

    Th. Brenner

    2015-02-01

    Full Text Available A first experimental demonstration of a new type of magnetic trap for ultra-cold neutrons is presented. High-field seeking spin-states are trapped in a potential formed by the magnetic field of a straight wire and a repulsive coating on the wire surface. Life-times of the trapped neutrons of 60 s could be observed. This configuration can in principle be used to form bound states of the wave function on the surface of the wire to probe new forces at short distances. Further applications include the use as a guide and selector for perfectly polarized neutrons.

  12. A magnetic trap for high-field seeking neutron spin states

    Energy Technology Data Exchange (ETDEWEB)

    Brenner, Th. [Institut Laue-Langevin, 38042 Grenoble Cedex 9 (France); Chesnevskaya, S. [Physik Department, Technische Universität München, D-85748 Garching (Germany); Fierlinger, P., E-mail: peter.fierlinger@tum.de [Physik Department, Technische Universität München, D-85748 Garching (Germany); Geltenbort, P. [Institut Laue-Langevin, 38042 Grenoble Cedex 9 (France); Gutsmiedl, E. [Physik Department, Technische Universität München, D-85748 Garching (Germany); Lauer, T. [Forschungsneutronenquelle Heinz Maier-Leibnitz, Technische Universität München, D-85748 Garching (Germany); Rezai, K. [University of California at Berkeley, CA 94720 (United States); Rothe, J. [Physik Department, Technische Universität München, D-85748 Garching (Germany); Zechlau, T. [Forschungsneutronenquelle Heinz Maier-Leibnitz, Technische Universität München, D-85748 Garching (Germany); Zou, R. [University of California at Berkeley, CA 94720 (United States)

    2015-02-04

    A first experimental demonstration of a new type of magnetic trap for ultra-cold neutrons is presented. High-field seeking spin-states are trapped in a potential formed by the magnetic field of a straight wire and a repulsive coating on the wire surface. Life-times of the trapped neutrons of 60 s could be observed. This configuration can in principle be used to form bound states of the wave function on the surface of the wire to probe new forces at short distances. Further applications include the use as a guide and selector for perfectly polarized neutrons.

  13. Time-Dependent Neutron and Photon Dose-Field Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wooten, Hasani Omar [Georgia Inst. of Technology, Atlanta, GA (United States)

    2005-08-01

    A unique tool is developed that allows the user to model physical representations of complicated glovebox facilities in two dimensions and determine neutral-particle flux and ambient dose-equivalent fields throughout that geometry. The Pandemonium code, originally designed to determine flux and dose-rates only, is improved to include realistic glovebox geometries, time-dependent source and detector positions, time-dependent shielding thickness calculations, time-integrated doses, a representative criticality accident scenario based on time-dependent reactor kinetics, and more rigorous photon treatment. A primary benefit of this work has been an extensive analysis and improvement of the photon model that is not limited to the application described in this thesis. The photon model has been extended in energy range to 10 MeV to include photons from fission and new photon buildup factors have been included that account for the effects of photon buildup at slant-path thicknesses as a function of angle, where the mean free path thickness has been preserved. The overall system of codes is user-friendly and it is directly applicable to facilities such as the plutonium facility at Los Alamos National Laboratory, where high-intensity neutron and photon emitters are regularly used. The codes may be used to determine a priori doses for given work scenarios in an effort to supply dose information to process models which will in turn assist decision makers on ensuring as low as reasonably achievable (ALARA) compliance. In addition, coupling the computational results of these tools with the process model visualization tools will help to increase worker safety and radiological safety awareness.

  14. Investigation of 186Re via radiative thermal-neutron capture on 185Re

    Science.gov (United States)

    Matters, D. A.; Lerch, A. G.; Hurst, A. M.; Szentmiklósi, L.; Carroll, J. J.; Detwiler, B.; Révay, Zs.; McClory, J. W.; McHale, S. R.; Firestone, R. B.; Sleaford, B. W.; Krtička, M.; Belgya, T.

    2016-05-01

    Partial γ -ray production cross sections and the total radiative thermal-neutron capture cross section for the 185Re(n ,γ ) 186Re reaction were measured using the Prompt Gamma Activation Analysis facility at the Budapest Research Reactor with an enriched 185Re target. The 186Re cross sections were standardized using well-known 35Cl(n ,γ )36Cl cross sections from irradiation of a stoichiometric natReCl3 target. The resulting cross sections for transitions feeding the 186Re ground state from low-lying levels below a cutoff energy of Ec=746 keV were combined with a modeled probability of ground-state feeding from levels above Ec to arrive at a total cross section of σ0=111 (6 ) b for radiative thermal-neutron capture on 185Re. A comparison of modeled discrete-level populations with measured transition intensities led to proposed revisions for seven tentative spin-parity assignments in the adopted level scheme for 186Re. Additionally, 102 primary γ rays were measured, including 50 previously unknown. A neutron-separation energy of Sn=6179.59 (5 ) keV was determined from a global least-squares fit of the measured γ -ray energies to the known 186Re decay scheme. The total capture cross section and separation energy results are comparable to earlier measurements of these values.

  15. Study of the thermal neutron radiative capture sup 31 P( n ,. gamma. ) reaction

    Energy Technology Data Exchange (ETDEWEB)

    Zeng Xiantang; Shi Zongren; Zhang Ming; Li Guohua; Ding Dazhao (Institute of Atomic Energy, P. O. Box 275, Beijing (CN))

    1989-05-01

    The measurement of the {gamma}-ray spectrum of the {sup 31}P({ital n},{gamma}) reaction induced by thermal neutrons from the heavy water reactor is performed by using three crystal pair spectrometer'', Ge(Li) and HPGe detectors. 128 {gamma}-rays are identified, 24 of them are recognized as primary {gamma}-transitions. The excitation energies of 32 levels are deduced. Two possible levels of 5451.44 keV and 5021.10 keV have not been reported previously. The neutron separation energy is determined to be 7936.65(8) keV and partial cross sections are measured. The thermal neutron capture cross section of {sup 31}P is obtained to be 177(5) mb by comparison with Au({ital n}{sub th}, {gamma}) cross section standard. With the formula of the Lane-Lynn direct interaction, the partial capture cross sections of eight strong primary E1-transitions are calculated and compared with their experimental values, leading to the conclusion that the theoretical values are in coincidence with the experimental ones and the E1-transitions mainly come from 1+ capture state. The correlation analyses of the reduced strengths of E1 and M1 transitions with the spectroscopic factors of (d, p) reaction are performed and the reaction mechanisms discussed.

  16. Defect annealing and thermal desorption of deuterium in low dose HFIR neutron-irradiated tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Masashi Shimada; M. Hara; T. Otsuka; Y. Oya; Y. Hatano

    2014-05-01

    Accurately estimating tritium retention in plasma facing components (PFCs) and minimizing its uncertainty are key safety issues for licensing future fusion power reactors. D-T fusion reactions produce 14.1 MeV neutrons that activate PFCs and create radiation defects throughout the bulk of the material of these components. Recent studies show that tritium migrates and is trapped in bulk (>> 10 µm) tungsten beyond the detection range of nuclear reaction analysis technique [1-2], and thermal desorption spectroscopy (TDS) technique becomes the only established diagnostic that can reveal hydrogen isotope behavior in in bulk (>> 10 µm) tungsten. Radiation damage and its recovery mechanisms in neutron-irradiated tungsten are still poorly understood, and neutron-irradiation data of tungsten is very limited. In this paper, systematic investigations with repeated plasma exposures and thermal desorption are performed to study defect annealing and thermal desorption of deuterium in low dose neutron-irradiated tungsten. Three tungsten samples (99.99 at. % purity from A.L.M.T. Co., Japan) irradiated at High Flux Isotope Reactor at Oak Ridge National Laboratory were exposed to high flux (ion flux of (0.5-1.0)x1022 m-2s-1 and ion fluence of 1x1026 m-2) deuterium plasma at three different temperatures (100, 200, and 500 °C) in Tritium Plasma Experiment at Idaho National Laboratory. Subsequently, thermal desorption spectroscopy (TDS) was performed with a ramp rate of 10 °C/min up to 900 °C, and the samples were annealed at 900 °C for 0.5 hour. These procedures were repeated three (for 100 and 200 °C samples) and four (for 500 °C sample) times to uncover damage recovery mechanisms and its effects on deuterium behavior. The results show that deuterium retention decreases approximately 90, 75, and 66 % for 100, 200, and 500 °C, respectively after each annealing. When subjected to the same TDS recipe, the desorption temperature shifts from 800 °C to 600 °C after 1st annealing

  17. Thermal-hydraulic simulation of mercury target concepts for a pulsed spallation neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Siman-Tov, M.; Wendel, M.; Haines, J. [Oak Ridge National Lab., TN (United States)

    1996-06-01

    The Oak Ridge Spallation Neutron Source (ORSNS) is a high-power, accelerator-based pulsed spallation neutron source being designed by a multi-laboratory team led by Oak Ridge National Laboratory to achieve very high fluxes of neutrons for scientific experiments. The ORSNS is projected to have a 1 MW proton beam upgradable to 5 MW. About 60% of the beam power (1-5 MW, 17-83 kJ/pulse in 0.5 microsec at 60 cps) is deposited in the liquid metal (mercury) target having the dimensions of 65x30x10 cm (about 19.5 liter). Peak steady state power density is about 150 and 785 MW/m{sup 3} for 1 MW and 5 MW beam respectively, whereas peak pulsed power density is as high as 5.2 and 26.1 GW/m{sup 3}, respectively. The peak pulse temperature rise rate is 14 million C/s (for 5 MW beam) whereas the total pulse temperature rise is only 7 C. In addition to thermal shock and materials compatibility, key feasibility issues for the target are related to its thermal-hydraulic performance. This includes proper flow distribution, flow reversals, possible {open_quotes}hot spots{close_quotes} and the challenge of mitigating the effects of thermal shock through possible injection of helium bubbles throughout the mercury volume or other concepts. The general computational fluid dynamics (CFD) code CFDS-FLOW3D was used to simulate the thermal and flow distribution in three preliminary concepts of the mercury target. Very initial CFD simulation of He bubbles injection demonstrates some potential for simulating behavior of He bubbles in flowing mercury. Much study and development will be required to be able to `predict`, even in a crude way, such a complex phenomena. Future direction in both design and R&D is outlined.

  18. ITHNA.SYS: An Integrated Thermal Hydraulic and Neutronic Analyzer SYStem for NUR research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Mazidi, S., E-mail: samirmazidi@gmail.com [Division Physique et Applications Nucléaires, Centre de Recherche Nucléaire de Draria (CRND), BP 43 Sebala, Draria, Alger (Algeria); Meftah, B., E-mail: b_meftah@yahoo.com [Division Physique et Applications Nucléaires, Centre de Recherche Nucléaire de Draria (CRND), BP 43 Sebala, Draria, Alger (Algeria); Belgaid, M., E-mail: belgaidm@yahoo.com [Faculté de Physique, Université Houari Boumediene, USTHB, BP 31, Bab Ezzouar, Alger (Algeria); Letaim, F., E-mail: fletaim@yahoo.fr [Faculté des Sciences et Technologies, Université d’El-oued, PO Box 789, El-oued (Algeria); Halilou, A., E-mail: hal_rane@yahoo.fr [Division Réacteur NUR, Centre de Recherche Nucléaire de Draria, BP 43 Sebala, Draria, Alger (Algeria)

    2015-08-15

    Highlights: • We develop a neutronic and thermal hydraulic MTR reactor analyzer. • The analyzer allows a rapid determination of the reactor core parameters. • Some NUR reactor parameters have been analyzed. - Abstract: This paper introduces the Integrated Thermal Hydraulic and Neutronic Analyzer SYStem (ITHNA.SYS) that has been developed for the Algerian research reactor NUR. It is used both as an operating aid tool and as a core physics engineering analysis tool. The system embeds three modules of the MTR-PC software package developed by INVAP SE: the cell calculation code WIMSD, the core calculation code CITVAP and the program TERMIC for thermal hydraulic analysis of a material testing reactor (MTR) core in forced convection. ITHNA.SYS operates both in on-line and off-line modes. In the on-line mode, the system is linked, via the computer parallel port, to the data acquisition console of the reactor control room and allows a real time monitoring of major physical and safety parameters of the NUR core. PC-based ITHNA.SYS provides a viable and convenient way of using an accumulated and often complex reactor physics stock of knowledge and frees the user from the intricacy of adequate reactor core modeling. This guaranties an accurate, though rapid, determination of a variety of neutronic and thermal hydraulic parameters of importance for the operation and safety analysis of the NUR research reactor. Instead of the several hours usually required, the processing time for the determination of such parameters is now reduced to few seconds. Validation of the system was performed with respect to experimental measurements and to calculations using reference codes. ITHNA.SYS can be easily adapted to accommodate other kinds of MTR reactors.

  19. The effects of intense magnetic fields on Landau levels in a neutron star

    Science.gov (United States)

    Gao, Z. F.; Wang, N.; Song, D. L.; Yuan, J. P.; Chou, C.-K.

    2011-08-01

    In this paper, an approximate method of calculating the Fermi energy of electrons ( E F ( e)) in a high-intensity magnetic field, based on the analysis of the distribution of a neutron star magnetic field, has been proposed. In the interior of a neutron star, different forms of intense magnetic field could exist simultaneously and a high electron Fermi energy could be generated by the release of magnetic field energy. The calculation results show that: E F ( e) is related to density ρ, the mean electron number per baryon Y e and magnetic field strength B.

  20. Thermal neutron detection by entrapping 6LiF nanocrystals in siloxane scintillators

    Science.gov (United States)

    Carturan, S. M.; Marchi, T.; Maggioni, G.; Gramegna, F.; Degerlier, M.; Cinausero, M.; Dalla Palma, M.; Quaranta, A.

    2015-06-01

    Exploiting the long experience in design and production of scintillating mixtures based on siloxane matrices with combinations of primary dye and waveshifter, a first set of 6LiF loaded scintillator disks has been produced. The synthesis is herein described and reported, as well as preliminary results on their light response towards thermal neutrons. The preservation of transparency and mechanical integrity of the scintillator material is challenging when introducing the inorganic salt LiF which is a "foreign body" to the organic polysiloxane host matrix Different strategies such as synthesis of nanoparticles and surface functionalization have been pursued to succeed in the entrapment of the neutron converter whilst maintaining moderate light output, optical transparency and flexibility of the base scintillator.

  1. Coupled neutronics/thermal-hydraulics and safety characteristics of liquid-fueled molten salt reactors

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, Suizheng; Zhang, Dalin; Liu, Minghao; Liu, Limin; Xu, Rongshuan; Gong, Cheng; Su, Guanghui [Xi' an Jiaotong Univ. (China). State Key Laboratory of Multiphase Flow in Power Engineering

    2016-05-15

    Molten salt reactor (MSR) as one candidate of the Generation IV advanced nuclear power systems is attracted more attention in China due to its top ranked fuel cycle and thorium utilization. The MSRs are characterized by using liquid-fuel, which offers complicated coupling problem of neutronics and thermal hydraulics. In this paper, the fundamental model and numerical method are established to calculate and analyze the safety characteristics for liquid-fuel MSRs. The theories and methodologies are applied to the MOSART concept. The liquid-fuel flow effects on neutronics, reactivity coefficients and three operation parameters' influences at steady state are obtained, which provide the basic information for safety analysis. The unprotected loss of flow transient is calculated, the results of which shows the inherent safety characteristics of MOSART due to its strong negative reactivity feedbacks.

  2. Influence of rapid thermal process on intrinsic gettering in fast neutron irradiated Czochralski silicon

    Institute of Scientific and Technical Information of China (English)

    CHEN Gui-feng; LI Yang-xian; LI Xing-hua; CAI Li-li; MA Qiao-yun; NIU Ping-juan; NIU Sheng-li; CHEN Dong-feng

    2006-01-01

    A rapid thermal process (RTP) was first introduced into the intrinsic gettering (IG) processes of fast neutron irradiated Czochralski (CZ) silicon. The effect of RTP conditions on bulk microdefects (BMDs) and denuded zone (DZ) was investigated. Fourier transform infrared absorption spectrometer (FTIR) was used to measure the concentration of interstitial oxygen ([Oi]). Bulk microdefects were observed by optical microscope. The results show that,according to the variation of [Oi],it is found that RTP doesn't change the processes of oxygen precipitation in fast neutron irradiated Czochralski silicon. Perfect denuded zone,dense oxygen precipitates and defects form in the bulk of irradiated samples. With increasing temperature of RTP,the width of denuded zone decreases. Increasing RTP cooling rate,the density of Bulk microdefects increases. DZ forms in the sample that annealed in nitrogen atmosphere.

  3. The influence of low dose neutron irradiation on the thermal conductivity of Allcomp carbon foam

    Energy Technology Data Exchange (ETDEWEB)

    Burchell, Timothy D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Porter, Wallace D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McDuffee, Joel Lee [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-03-01

    Oak Ridge National Laboratory was contracted via a Work for Others Agreement with Allcomp Inc. (NFE-14-05011-MSOF: Carbon Foam for Beam Stop Applications ) to determine the influence of low irradiation dose on the thermal conductivity of Allcomp Carbon Foam. Samples (6 mm dia. x 5 mm thick) were successfully irradiated in a rabbit capsule in a hydraulic tube in the target region of the High Flux Isotope Reactor at the Oak Ridge National Laboratory. The specimens were irradiated at Tirr = 747.5 C to a neutron damage dose of 0.2 dpa. There is a small dimensional and volume shrinkage and the mass and density appear reduced (we would expect density to increase as volume reduces at constant mass). The small changes in density, dimensions or volume are not of concern. At 0.2 dpa the irradiation shrinkage rate difference between the glassy carbon skeleton and the CVD coating was not sufficient to cause a large enough irradiation-induced strain to create any mechanical degradation. Similarly differential thermal expansion was not a problem. It appears that only the thermal conductivity was affected by 0.2 dpa. For the intended application conditions, i.e. @ 400 C and 0 DPA (start- up) the foam thermal conductivity is about 57 W/m.K and at 700 C and 0.2 DPA (end of life) the foam thermal conductivity is approx. 30.7 W/m.K. The room temp thermal conductivity drops from 100-120 W/m.K to approximately 30 W/m.K after 0.2 dpa of neutron irradiation.

  4. Magnetic field component demonstration for a neutron electric dipole moment search

    Science.gov (United States)

    Slutsky, Simon

    2016-09-01

    A neutron electric dipole moment (EDM) search at the Oak Ridge National Laboratory's Spallation Neutron Source (SNS) will probe with a sensitivity of EDM will appear as a variation in the precession frequency correlated with the electric field. Magnetic field gradients must be kept below 10 pT/cm to mitigate false EDMs produced by the geometric phase effect and to maximize the neutron spin-relaxation lifetime. I will discuss a prototype magnetic shielding system, including a nearly-hermetic superconducting lead shield, built to demonstrate the required gradients at 1/3-scale of the final experiment. Additionally, the system will evaluate the eddy current heating due to RF fields produced by a proposed neutron-``spin-dressing'' technique.

  5. Measurement of Insulation Compaction in the Cryogenic Fuel Tanks at Kennedy Space Center by Fast/Thermal Neutron Techniques

    Science.gov (United States)

    Livingston, R. A.; Schweitzer, J. S.; Parsons, Ann M.; Arens, Ellen E.

    2010-01-01

    The liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC) use expanded perlite as thermal insulation. Th ere is evidence that some of the perlite has compacted over time, com promising the thermal performance and possibly also structural integr ity of the tanks. Therefore an Non-destructive Testing (NDT) method for measuring the perlite density or void fraction is urgently needed. Methods based on neutrons are good candidates because they can readil y penetrate through the 1.75 cm outer steel shell and through the ent ire 120 cm thickness of the perlite zone. Neutrons interact with the nuclei of materials to produce characteristic gamma rays which are the n detected. The gamma ray signal strength is proportional to the atom ic number density. Consequently, if the perlite is compacted then the count rates in the individual peaks in the gamma ray spectrum will i ncrease. Perlite is a feldspathic volcanic rock made up of the major elements Si, AI, Na, K and 0 along with some water. With commercially available portable neutron generators it is possible to produce simul taneously fluxes of neutrons in two energy ranges: fast (14 MeV) and thermal (25 meV). Fast neutrons produce gamma rays by inelastic scatt ering which is sensitive to Fe and O. Thermal neutrons produce gamma rays by radiative capture in prompt gamma neutron activation (PGNA) and this is sensitive to Si, AI, Na, Kand H. Thus the two energy ranges produce complementary information. The R&D program has three phases: numerical simulations of neutron and gamma ray transport with MCNP s oftware, evaluation of the system in the laboratory on test articles and finally mapping of the perlite density in the cryogenic tanks at KSC. The preliminary MCNP calculations have shown that the fast/therma l neutron NDT method is capable of distinguishing between expanded an d compacted perlite with excellent statistics.

  6. Determination of calibration function in thermal field flow fractionation under thermal field programming.

    Science.gov (United States)

    Pastil, Luisa; Ventosa, Edgar A; Mingozzi, Ines; Dondi, Francesco

    2006-05-01

    A new procedure for determining the calibration function able to relate retention and operative parameters to molecular weight of the species in thermal field flow (ThFFF) under thermal field programming (TFP) conditions is presented. The procedure involves determining the average values of retention parameters under TFP and determining a numerical function related to the temperature variations that occur during TFP. The calibration parameters are obtained by a procedure fitting the retention and operative parameters that hold true at the beginning of the TFP. The procedure is closely related to the one previously developed to calibrate the retention time axis under TFP ThFFF and, together, they constitute a full calibration procedure. Experimental validation was performed with reference to polystyrene (PS)-decalin and PS-THF systems. The calibration functions here obtained were compared to those derived by the classical procedure at constant thermal field ThFFF to obtain the calibration function at variable cold wall temperatures. Excellent agreement was found in all cases proving "universality" of the ThFFF calibration concept, i.e. it is independent of the particular system on which it was determined and can thus be extended to ThFFF operating under TFP. The new procedure is simpler than the classical one since it requires less precision in setting the instrumentation and can be obtained with fewer experiments. The potential applications for the method are discussed.

  7. A new monitor for routine thermal and epithermal neutron fluence rate monitoring in k{sub 0} INAA

    Energy Technology Data Exchange (ETDEWEB)

    Koster-Ammerlaan, M.J.J. [Delft University of Technology, Reactor Institute Delft, Mekelweg 15, 2629JB Delft (Netherlands)], E-mail: m.j.j.koster-ammerlaan@tudelft.nl; Bacchi, M.A. [Centro de Energia Nuclear na Agricultura, Universidade de Sao Paulo 13400-970, Piracicaba (Brazil); Bode, P. [Delft University of Technology, Reactor Institute Delft, Mekelweg 15, 2629JB Delft (Netherlands); Nadai Fernandes, E.A. de [Centro de Energia Nuclear na Agricultura, Universidade de Sao Paulo 13400-970, Piracicaba (Brazil)

    2008-12-15

    The Zr-Au set for monitoring the thermal and epithermal neutron fluence rate and the epithermal spectrum parameter {alpha} is not always practicable for routine application of INAA in well-thermalized facilities. An alternative set consisting of Cr, Au and Mo provides values for the thermal neutron fluence rate, f and {alpha} that are not significantly different from those found via the Zr-Au method and the Cd-covered Zr-method. The IRMM standard SMELS-II was analyzed using the (Au-Cr-Mo) monitor and a good agreement was obtained.

  8. Estimating field scale root zone soil moisture using the cosmic-ray neutron probe

    Science.gov (United States)

    Peterson, A. M.; Helgason, W. D.; Ireson, A. M.

    2015-12-01

    Many practical hydrological, meteorological and agricultural management problems require estimates of soil moisture with an areal footprint equivalent to "field scale", integrated over the entire root zone. The cosmic-ray neutron probe is a promising instrument to provide field scale areal coverage, but these observations are shallow and require depth scaling in order to be considered representative of the entire root zone. A study to identify appropriate depth-scaling techniques was conducted at a grazing pasture site in central Saskatchewan, Canada over a two year period. Area-averaged soil moisture was assessed using a cosmic-ray neutron probe. Root zone soil moisture was measured at 21 locations within the 5002 m2 area, using a down-hole neutron probe. The cosmic-ray neutron probe was found to provide accurate estimates of field scale surface soil moisture, but accounted for less than 40 % of the seasonal change in root zone storage due to its shallow measurement depth. The root zone estimation methods evaluated were: (1) the coupling of the cosmic-ray neutron probe with a time stable neutron probe monitoring location, (2) coupling the cosmic-ray neutron probe with a representative landscape unit monitoring approach, and (3) convolution of the cosmic-ray neutron probe measurements with the exponential filter. The time stability method provided the best estimate of root zone soil moisture (RMSE = 0.004 cm3 cm-3), followed by the exponential filter (RMSE = 0.012 cm3 cm-3). The landscape unit approach, which required no calibration, had a negative bias but estimated the cumulative change in storage reasonably. The feasibility of applying these methods to field sites without existing instrumentation is discussed. It is concluded that the exponential filter method has the most potential for estimating root zone soil moisture from cosmic-ray neutron probe data.

  9. Describing one- and two-neutron halos in effective field theory

    Indian Academy of Sciences (India)

    Daniel R Phillips

    2014-11-01

    In this paper, the recent work our group has undertaken on effective field theory (EFT) analyses of experimental data pertaining to one- and two-neutron halo nuclei is discussed. The cases of 19C and 8Li (one-neutron halos) and 22C (two-neutron halo) are considered. For 19C and 8Li electromagnetic processes, such as Coulomb dissociation and radiative capture are considered. In the 22C system the way in which the measured matter radius can be used to derive constraints on the two-neutron separation energy of this very neutron-rich system is shown. In each case the Halo EFT’s ability to correlate different experimental observables with one another, in a modelindependent manner, and up to an accuracy that is determined by the separation of scales in the halo system is shown.

  10. Neutron Spectrum of Thermal Neutron Beam in IHNI%医院中子照射器热中子束能谱特性研究

    Institute of Scientific and Technical Information of China (English)

    鲁谨; 刘心灵; 夏普; 李义国; 彭旦; 吴小波; 张金花; 邹淑芸; 洪景彦; 郝倩

    2012-01-01

    In-Hospital Neutron Irradiator (IHNI) is the first miniature neutron source reactor for special medical treatment purpose. It got critical on December 7th, 2009, and went to full power on January 22th, 2010. Parameters, such as the neutron flux density and neutron spectrum of the thermal neutron beam in IHNI, should be given before the medical treatment. Model was built and calculation results were given by MCNP program. The neutron flux density was measured by gold foil activation technique, and the neutron spectrum was measured by multiple foils activation technique and unfolded by SAND-Ⅱ program. Detectors were irradiated and then measured by HPGe. Neutron flux density and distribution was given, and neutron spectrum was unfolded with SAND-Ⅱ program.%医院中子照射器是我国建造的第1座用于医疗目的的微型反应堆,已于2009年12月7日首次达临界,2010年1月22日达到满功率运行.在治疗前,需测量出口处的中子通量密度及能谱等参数,为后续实验提供依据.本文用MCNP建立医院中子照射器模型,得到能谱计算值.选用金箔活化法测量绝对中子通量密度,多箔活化法测量中子能谱,用SAND-Ⅱ程序解谱,并将实验结果与计算结果进行了比较.

  11. Neutronic and thermal-hydraulic analysis of fission molybdenum-99 production at Tehran Research Reactor using LEU plate targets.

    Science.gov (United States)

    Abedi, Ebrahim; Ebrahimkhani, Marzieh; Davari, Amin; Mirvakili, Seyed Mohammad; Tabasi, Mohsen; Maragheh, Mohammad Ghannadi

    2016-12-01

    Efficient and safe production of molybdenum-99 ((99)Mo) radiopharmaceutical at Tehran Research Reactor (TRR) via fission of LEU targets is studied. Neutronic calculations are performed to evaluate produced (99)Mo activity, core neutronic safety parameters and also the power deposition values in target plates during a 7 days irradiation interval. Thermal-hydraulic analysis has been also carried out to obtain thermal behavior of these plates. Using Thermal-hydraulic analysis, it can be concluded that the safety parameters are satisfied in the current study. Consequently, the present neutronic and thermal-hydraulic calculations show efficient (99)Mo production is accessible at significant activity values in TRR current core configuration. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Effects of Magnetic Field Topology on Secondary Neutron Spectra in MagLIF

    Science.gov (United States)

    Appelbe, Brian; Chittenden, Jeremy

    2015-11-01

    Ignition in Magneto-Inertial Fusion schemes requires both inertial and magnetic confinement of the fuel and charged fusion products. Recent theoretical and experimental work has demonstrated the confinement of charged fusion products by magnetic fields in Magnetized Liner Inertial Fusion (MagLIF) experiments. This confinement can be inferred from the ratio of secondary to primary neutron yields and the shape of secondary neutron spectra. In this work we investigate the effects of magnetic field topology on the shape of secondary neutron spectra. The MagLIF design has a cylindrical geometry and includes both axial and azimuthal magnetic fields. The azimuthal field is initially in the liner surrounding the fuel but instability growth may cause it to penetrate into the fuel. Charged fusion products (such as tritons or alpha particles) that are isotropically emitted and then confined by an axial field will flow parallel and anti-parallel to the field with equal intensities. In the case of tritons, this motion results in a secondary neutron spectrum emitted in the axial direction that is symmetric. However, in an azimuthal field such particles exhibit singular orbits and there is a net ion drift along the axis. This ion drift can cause the secondary neutron spectrum to be asymmetric. We examine the effects on the spectrum shape of confinement by a combination of axial and azimuthal fields.

  13. Effects of neutrino emissivity on the cooling of neutron stars in the presence of a strong magnetic field

    Science.gov (United States)

    Coelho, Eduardo Lenho; Chiapparini, Marcelo; Negreiros, Rodrigo Picanço

    2015-12-01

    One of the most interesting kind of neutron stars are the pulsars, which are highly magnetized neutron stars with fields up to 1014 G at the surface. The strength of magnetic field in the center of a neutron star remains unknown. According to the scalar virial theorem, magnetic field in the core could be as large as 1018 G. In this work we study the influence of strong magnetic fields on the cooling of neutron stars coming from direct Urca process. Direct Urca process is an extremely efficient mechanism for cooling a neutron star after its formation. The matter is described using a relativistic mean-field model at zero temperature with eight baryons (baryon octet), electrons and muons. We obtain the relative population of each species of particles as function of baryon density for different magnetic fields. We calculate numerically the cooling of neutron stars for a parametrized magnetic field and compare the results for the case without a magnetic field.

  14. Performance of a PADC personal neutron dosemeter at simulated and real workplace fields of the nuclear industry.

    Science.gov (United States)

    Fiechtner, A; Boschung, M; Wernli, C

    2007-01-01

    In the framework of the EVIDOS (Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields) project, funded by the EC, measurements with PADC personal neutron dosemeters were carried out at several workplace fields of the nuclear industry and at simulated workplace fields. The measured personal neutron dose equivalents of the PADC personal neutron dosemeter are compared with values that were assessed within the EVIDOS project by other partners. The detection limits for different spectra types are given. In cases were the neutron dose was too low to be measured by the PADC personal neutron dosemeter, the response is estimated by convoluting the responses to monoenergetic neutrons with the dose energy distribution measured within EVIDOS. The advantages and limitations of the PADC personal neutron dosemeter are discussed.

  15. Measurement of thermal neutron cross-sections and resonance integrals for sup 7 sup 1 Ga(n,gamma) sup 7 sup 2 Ga and sup 7 sup 5 As(n,gamma) sup 7 sup 6 As by using sup 2 sup 4 sup 1 Am-Be isotopic neutron source

    CERN Document Server

    Karadag, M; Tan, M; Oezmen, A

    2003-01-01

    Thermal neutron cross-sections and resonance integrals for the sup 7 sup 1 Ga(n,gamma) sup 7 sup 2 Ga and sup 7 sup 5 As(n,gamma) sup 7 sup 6 As reactions were measured by the activation method. The experimental samples with and without a cylindrical Cd shield case in 1 mm wall thickness were irradiated in an isotropic neutron field of the sup 2 sup 4 sup 1 Am-Be neutron source. The induced activities in the samples were measured by high-resolution gamma-ray spectrometry with a calibrated reverse-electrode germanium detector. Thermal neutron cross-sections for 2200 m/s neutrons and resonance integrals for the sup 7 sup 1 Ga(n,gamma) sup 7 sup 2 Ga and sup 7 sup 5 As(n,gamma) sup 7 sup 6 As reactions have been obtained relative to the reference values, sigma sub 0 =13.3+-0.1 b and I sub 0 =14.0+-0.3 b for the sup 5 sup 5 Mn(n,gamma) sup 5 sup 6 Mn reaction as a single comparator. The necessary correction factors for gamma attenuation, thermal neutron and resonance neutron self-shielding effects were taken into...

  16. Thermal hydraulic design and decay heat removal of a solid target for a spallation neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Takenaka, N. [Department of Mechanical Engineering, Kobe University, Kobe (Japan)]. E-mail: takenaka@mech.kobe-u.ac.jp; Nio, D. [Hokkaido University, Sapporo (Japan); Kiyanagi, Y. [Hokkaido University, Sapporo (Japan); Mishima, K. [Kyoto University Research Reactor Institute, Kumatori (Japan); Kawai, M. [High Energy Accelerator Research Institute, Tsukuba (Japan); Furusaka, M. [High Energy Accelerator Research Institute, Tsukuba (Japan)

    2005-08-01

    Thermal hydraulic design and thermal stress calculations were conducted for a water-cooled solid target irradiated by a MW-class proton beam for a spallation neutron source. Plate type and rod bundle type targets were examined. The thickness of the plate and the diameter of the rod were determined based on the maximum and the wall surface temperature. The thermal stress distributions were calculated by a finite element method (FEM). The neutronics performance of the target is roughly proportional to its average density. The averaged densities of the designed targets were calculated for tungsten plates, tantalum-clad tungsten plates, tungsten rods sheathed by tantalum and Zircaloy and they were compared with mercury density. It was shown that the averaged density was highest for the tungsten plates and was high for the tantalum cladding tungsten plates, the tungsten rods sheathed by tantalum and Zircaloy in order. They were higher than or equal to that of mercury for the 1-2 MW proton beams. Tungsten target without the cladding or the sheath is not practical due to corrosion by water under irradiation condition. Therefore, the tantalum cladding tungsten plate already made successfully by HIP and the sheathed tungsten rod are the candidate of high performance solid targets. The decay heat of each target was calculated. It was low enough low compared to that of ISIS for the target without tantalum but was about four times as high as that of ISIS when the thickness of the tantalum cladding was 0.5 mm. Heat removal methods of the decay heat with tantalum were examined. It was shown that a special cooling system was required for the target exchange when tantalum was used for the target. It was concluded that the tungsten rod target sheathed with stainless steel or Zircaloy was the most reliable from the safety considerations and had similar neutronics performance to that of mercury.

  17. Thermal hydraulic design and decay heat removal of a solid target for a spallation neutron source

    Science.gov (United States)

    Takenaka, N.; Nio, D.; Kiyanagi, Y.; Mishima, K.; Kawai, M.; Furusaka, M.

    2005-08-01

    Thermal hydraulic design and thermal stress calculations were conducted for a water-cooled solid target irradiated by a MW-class proton beam for a spallation neutron source. Plate type and rod bundle type targets were examined. The thickness of the plate and the diameter of the rod were determined based on the maximum and the wall surface temperature. The thermal stress distributions were calculated by a finite element method (FEM). The neutronics performance of the target is roughly proportional to its average density. The averaged densities of the designed targets were calculated for tungsten plates, tantalum clad tungsten plates, tungsten rods sheathed by tantalum and Zircaloy and they were compared with mercury density. It was shown that the averaged density was highest for the tungsten plates and was high for the tantalum cladding tungsten plates, the tungsten rods sheathed by tantalum and Zircaloy in order. They were higher than or equal to that of mercury for the 1 2 MW proton beams. Tungsten target without the cladding or the sheath is not practical due to corrosion by water under irradiation condition. Therefore, the tantalum cladding tungsten plate already made successfully by HIP and the sheathed tungsten rod are the candidate of high performance solid targets. The decay heat of each target was calculated. It was low enough low compared to that of ISIS for the target without tantalum but was about four times as high as that of ISIS when the thickness of the tantalum cladding was 0.5 mm. Heat removal methods of the decay heat with tantalum were examined. It was shown that a special cooling system was required for the target exchange when tantalum was used for the target. It was concluded that the tungsten rod target sheathed with stainless steel or Zircaloy was the most reliable from the safety considerations and had similar neutronics performance to that of mercury.

  18. Mean-field versus microconvection effects in nanofluid thermal conduction.

    Science.gov (United States)

    Eapen, Jacob; Williams, Wesley C; Buongiorno, Jacopo; Hu, Lin-Wen; Yip, Sidney; Rusconi, Roberto; Piazza, Roberto

    2007-08-31

    Transient hot-wire data on thermal conductivity of suspensions of silica and perfluorinated particles show agreement with the mean-field theory of Maxwell but not with the recently postulated microconvection mechanism. The influence of interfacial thermal resistance, convective effects at microscales, and the possibility of thermal conductivity enhancements beyond the Maxwell limit are discussed.

  19. Mean-Field Versus Microconvection Effects in Nanofluid Thermal Conduction

    Science.gov (United States)

    Eapen, Jacob; Williams, Wesley C.; Buongiorno, Jacopo; Hu, Lin-Wen; Yip, Sidney; Rusconi, Roberto; Piazza, Roberto

    2007-08-01

    Transient hot-wire data on thermal conductivity of suspensions of silica and perfluorinated particles show agreement with the mean-field theory of Maxwell but not with the recently postulated microconvection mechanism. The influence of interfacial thermal resistance, convective effects at microscales, and the possibility of thermal conductivity enhancements beyond the Maxwell limit are discussed.

  20. Calibration approaches of cosmic-ray neutron sensing for soil moisture measurement in cropped fields

    Directory of Open Access Journals (Sweden)

    C. A. Rivera Villarreyes

    2013-04-01

    Full Text Available Measurement of soil moisture at the plot or hill-slope scale is an important link between local vadose-zone hydrology and catchment hydrology. This study evaluates the applicability of the cosmic-ray neutron sensing for soil moisture in cropped fields. Measurements of cosmic-ray neutrons (fast neutrons were performed at a lowland farmland in Bornim (Brandenburg, Germany cropped with sunflower and winter rye. Three field calibration approaches and four different ways of integration the soil moisture profile to an integral value for cosmic-ray neutron sensing were evaluated in this study. The cosmic-ray sensing (CRS probe was calibrated against a network of classical point-scale soil moisture measurements. A large CRS parameter variability was observed by choosing calibration periods within the different growing stages of sunflower and winter rye. Therefore, it was not possible to identify a single set of parameters perfectly estimating soil moisture for both sunflower and winter rye periods. On the other hand, CRS signal and its parameter variability could be understood by some crop characteristics and by predicting the attenuated neutrons by crop presence. This study proves the potentiality of the cosmic-ray neutron sensing at the field scale; however, its calibration needs to be adapted for seasonal vegetation in cropped fields.

  1. Levels of 188Re nucleus populated in thermal neutron capture reaction

    Science.gov (United States)

    Běrziņš, J.; Krasta, T.; Simonova, L.; Balodis, M.; Bondarenko, V.; Jentschel, M.; Urban, W.; Tomandl, I.

    2016-03-01

    Levels of 188Re populated in thermal neutron capture reaction with enriched 187Re targets have been studied. Single γ-ray spectrum of 188Re, measured with the high-resolution crystal diffraction spectrometer GAMS5, as well as γγ-coincidence experiments performed with high efficiency Ge detectors, allowed to develop model-independent level scheme of the doubly-odd 188Re nucleus up to ˜ 1.5 MeV excitation energy. Analysis of the established 188Re level scheme in terms of the quasiparticle-plus-rotor model indicates coexistence of axially-deformed and triaxial structures in the energy range above 400 keV.

  2. Thermal neutron absorption cross section and clay mineral content for Miocene Carpathian samples

    Science.gov (United States)

    Woznicka

    2000-12-01

    A correlation between the thermal neutron absorption cross section and the clay volume for samples from the chosen geological region is discussed. A comparison of the calculated and measured absorption cross sections as a function of clay volume allows an estimate to be made on the presence of highly absorbing impurities in clays. From the example presented, it was deduced that 105 ppm of B or 25 ppm of Gd in the clay minerals in the samples tested would be sufficient to explain the difference between the experimental and calculated cross sections.

  3. Relativistic theory of inverse beta-decay of polarized neutron in strong magnetic field

    Indian Academy of Sciences (India)

    S Shinkevich; A Studenikin

    2005-08-01

    The relativistic theory of the inverse beta-decay of polarized neutron, + → + -, in strong magnetic field is developed. For the proton wave function we use the exact solution of the Dirac equation in the magnetic filed that enables us to account exactly for effects of the proton momentum quantization in the magnetic field and also for the proton recoil motion. The effect of nucleons anomalous magnetic moments in strong magnetic fields is also discussed. We examine the cross-section for different energies and directions of propagation of the initial neutrino accounting for neutron polarization. It is shown that in the super-strong magnetic field the totally polarized neutron matter is transparent for neutrinos propagating antiparallel to the direction of polarization. The developed relativistic approach can be used for calculations of cross-sections of the other URCA processes in strong magnetic fields.

  4. Neutron calibration field of bare {sup 252}Cf source in Vietnam

    Energy Technology Data Exchange (ETDEWEB)

    Le, Ngoc Thiem; Tran, Hoai Nam; Nguyen, Khai Tuan [Institute for Nuclear Science and Technology, Hanoi (Viet Nam); Trinh, Glap Van [Institute of Research and Development, Duy Tan University, Da Nang (Viet Nam)

    2017-02-15

    This paper presents the establishment and characterization of a neutron calibration field using a bare {sup 252}Cf source of low neutron source strength in Vietnam. The characterization of the field in terms of neutron flux spectra and neutron ambient dose equivalent rates were performed by Monte Carlo simulations using the MCNP5 code. The anisotropy effect of the source was also investigated. The neutron ambient dose equivalent rates at three reference distances of 75, 125, and 150 cm from the source were calculated and compared with the measurements using the Aloka TPS-451C neutron survey meters. The discrepancy between the calculated and measured values is found to be about 10%. To separate the scattered and the direct components from the total neutron flux spectra, an in-house shadow cone of 10% borated polyethylene was used. The shielding efficiency of the shadow cone was estimated using the MCNP5 code. The results confirmed that the shielding efficiency of the shadow cone is acceptable.

  5. Thermal, intermediate and fast neutron flux measurements using activation detectors; Mesure des flux de neutrons thermiques, intermediaires et rapides au moyen de detecteurs par activation

    Energy Technology Data Exchange (ETDEWEB)

    Brisbois, J.; Lott, M.; Manent, G. [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    The problem of neutron flux measurements using activation detectors is studied in the particular case of protection research. It is shown how it possible, it is possible, using a known thermal flux, to organise a coherent calibration system for all the detectors. The rapid neutron detectors are calibrated with respect to a reference detector (phosphorus) in a natural uranium converter; the intermediate neutron detectors with respect to gold in the axial channel of ZOE. This method makes it possible to minimise the errors due to the activation cross-sections. A brief description is given of the counting room of the Pile Safety Study Service, as well of the practical utilisation characteristics of the counters employed. (authors) [French] Le probleme de la mesure des flux de neutrons au moyen de detecteurs par activation est etudie dans le cas particulier des etudes de protections. On montre comment, a partir d'un flux thermique connu, on peut organiser un systeme coherent d'etalonnage de tous les detecteurs. Les detecteurs de neutrons rapides sont etalonnes par rapport a un detecteur de reference (phosphore) dans un convertisseur en uranium naturel; les detecteurs de neutrons intermediaires, par rapport a l'or dans le canal axial de ZOE, Cette methode permet de minimiser les erreurs dues aux sections efficaces d'activation. On decrit sommairement la salle de comptage du Service d'Etudes de Protections de Piles et on indique les caracteristiques d'emploi pratique des detecteurs utilises. (auteurs)

  6. Neutron scattering studies of a frustrated spinel antiferromagnet in zero and high magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, M [Quantum Beam Science Directorate, Japan Atomic Energy Agency (JAEA), Tokai, Ibaraki 319-1195 (Japan)

    2006-11-15

    A review is given of the neutron scattering studies on a frustrated spinel antiferromagnet CdCr{sub 2}O{sub 4}. As observed in ZnCr{sub 2}O{sub 4}, which has been most extensively studied in the Cr-based spinel oxides, CdCr{sub 2}O{sub 4} also shows an antiferromagnetic phase transition and a structural phase transition simultaneously, indicating a strong spin-lattice coupling. The magnetic structure of CdCr{sub 2}O{sub 4}was determined by neutron scattering studies. The neutron scattering study in magnetic field up to 10 T indicates an orientation of magnetic domains.

  7. Numerical solutions of general-relativistic field equations for rapidly rotating neutron stars

    Institute of Scientific and Technical Information of China (English)

    吴雪君; 须重明

    1997-01-01

    Stationary axial symmetric equilibrium configurations rapidly rotating with uniform angular velocity in the framework of genera! relativity are considered. Sequences of models are numerically computed by means of a computer code that solves the full Einstein equations exactly. This code employs Neugebauer’s minimal surface formalism, where the field equations are equivalent to two-dimensional minimal surface equations for 4 metric potentials. The calculations are based upon 10 different equations of state. Results of various structures of neutron stars and the rotational effects on stellar structures and properties are reported. Finally some limits to equations of state of neutron stars and the stability for rapidly rotating relativistic neutron stars are discussed.

  8. Neutron field measurements at the 590 MeV ring cyclotron of the Paul Scherrer Institute

    CERN Document Server

    Grecescu, M; Boschung, M; Fiechtner, A; Gmuer, K; Laedermann, J P; Valley, J F; Wernli, C

    2002-01-01

    A complete characterization of the neutron field was performed at 3 representative areas around the 590 MeV Ring cyclotron of the Paul Scherrer Institute. The neutron spectra were measured with a Bonner spheres system, sup 2 sup 0 sup 9 Bi and sup 2 sup 3 sup 2 Th fission track detectors. Their shapes are very different according to the location; neutron energies up to about 200 MeV were recorded. The dosimetry was performed with various active instruments: 2202D, LB 6411, LINUS, nm 500, nm 500X, HANDI, REM 500. The comparison between the H*(10) values determined by different systems is presented and discussed.

  9. Demonstration of a white beam far-field neutron interferometer for spatially resolved small angle neutron scattering

    CERN Document Server

    Hussey, Daniel S; Yuan, Guangcui; Pushin, Dmitry; Sarenac, Dusan; Huber, Michael G; Jacobson, David L; LaManna, Jacob M; Wen, Han

    2016-01-01

    We provide the first demonstration that a neutron far-field interferometer can be employed to measure the microstructure of a sample. The interferometer is based on the moir\\'e pattern of two phase modulating gratings which was previously realized in hard x-ray and visible light experiments. The autocorrelation length of this interferometer, and hence the microstructure length scale that is probed, is proportional to the grating spacing and the neutron wavelength, and can be varied over several orders of magnitude for one pair of gratings. We compare our measurements of the change in visibility from monodisperse samples with calculations which show reasonable agreement. The potential advantages of a far-field neutron interferometer include high fringe visibility in a polychromatic beam (over 30 %), no requirement for an absorbing grating to resolve the interference fringes, and the ability to measure the microstructure in the length scale range of 100 nm to 10 \\mum by varying either the grating spacing or neu...

  10. On the optimization of the isotopic neutron source method for measuring the thermal neutron absorption cross section: advantages and disadvantages of BF3 and 3He counters.

    Science.gov (United States)

    Bolewski, A; Ciechanowski, M; Dydejczyk, A; Kreft, A

    2008-04-01

    The effect of the detector characteristics on the performance of an isotopic neutron source device for measuring thermal neutron absorption cross section (Sigma) has been examined by means of Monte Carlo simulations. Three specific experimental arrangements, alternately with BF(3) counters and (3)He counters of the same sizes, have been modelled using the MCNP-4C code. Results of Monte Carlo calculations show that devices with BF(3) counters are more sensitive to Sigma, but high-pressure (3)He counters offer faster assays.

  11. Thermal neutron cross-section and resonance integral of the 152Sm(n,γ)153Sm reaction induced by pulsed neutrons

    Science.gov (United States)

    Van Do, Nguyen; Khue, Pham Duc; Thanh, Kim Tien; Hien, Nguyen Thi; Kim, Guinyun; Kim, Kwangsoo; Shin, Sung-Gyun; Kye, Yong-Uk; Cho, Moo-Hyun

    2017-10-01

    We measured the thermal neutron cross-section (σ0) and resonance integral (I0) of the 152Sm(n,γ)153Sm reaction relative to that of the 197Au(n,γ)198Au reaction. Sm and Au foils with and without a cadmium cover of 0.5 mm were irradiated with moderated pulsed neutrons produced from the electron linac. The induced activities of the reaction products were determined via high energy resolution HPGe detector. The present results: σ0,Sm =212±8 b and I0,Sm =3.02±0.19 kb are consistent with most of the existing reference data.

  12. Neutron field measurements of the CRNA OB26 irradiator using a Bonner sphere spectrometer for radiation protection purposes.

    Science.gov (United States)

    Mazrou, H; Allab, M

    2012-08-01

    The present work deals with the Bonner sphere spectrometer (BSS) measurements performed, to support the authors' Monte-Carlo calculations, to estimate accurately the main characteristics of the neutron field of the (241)Am-Be-based OB26 irradiator acquired for radiation protection purposes by the Nuclear Research Centre of Algiers. The measurements were performed at a reference irradiation position selected at 150 cm from the geometrical centre of the neutron source. The spectrometric system in use is based on a central spherical (3)He thermal neutron proportional counter. The response matrix of the present spectrometer has been taken to be similar to the original Physikalisch-Technische Bundesanstalt (PTB) (Braunschweig, Germany) BSS's response matrix, with a five bins per decade energy group structure, as there is no significant difference in the BSS's physical characteristics. Thereafter, the authors' BSS measurements were used together with MCNP5 results to unfold the neutron spectrum by means of MAXED and GRAVEL computer codes from the U.M.G. 3.3 package, developed at PTB. Besides, sensitivity analysis has been performed to test the consistency of the unfolding procedure. It reveals that no significant discrepancy was observed in the total neutron fluence and total ambient dose values following the perturbation of some pertinent unfolding parameters except for the case where a 10 bins energy structure was assumed for the guess spectrum. In this latter case, a 5 % difference was observed in the ambient dose equivalent compared with the reference case. Finally, a comparative study performed between different counting systems together with MCNP5 and predictive formulas results shows that they were globally satisfactory, highlighting thereby the relevance of the unfolding procedure and the reliability of the obtained results.

  13. Compton Scattering Cross Sections in Strong Magnetic Fields: Advances for Neutron Star Applications

    Science.gov (United States)

    Ickes, Jesse; Gonthier, Peter L.; Eiles, Matthew; Baring, Matthew G.; Wadiasingh, Zorawar

    2014-08-01

    Various telescopes including RXTE, INTEGRAL, Suzaku and Fermi have detected steady non-thermal X-ray emission in the 10 ~ 200 keV band from strongly magnetic neutron stars known as magnetars. Magnetic inverse Compton scattering is believed to be a leading candidate for the production of this intense X-ray radiation. Generated by electrons possessing ultra-relativistic energies, this leads to attractive simplifications of the magnetic Compton cross section. We have recently addressed such a case by developing compact analytic expressions using correct spin-dependent widths acquired through the implementation of Sokolov & Ternov (ST) basis states, focusing specifically on ground state-to-ground state scattering. Such scattering in magnetar magnetospheres can cool electrons down to mildly-relativistic energies. Moreover, soft gamma-ray flaring in magnetars may well involve strong Comptonization in expanding clouds of mildly-relativistic pairs. These situations necessitate the development of more general magnetic scattering cross sections, where the incoming photons acquire substantial incident angles relative to the field in the rest frame of the electron, and the intermediate state can be excited to arbitrary Landau levels. Here, we highlight results from such a generalization using ST formalism. The cross sections treat the plethora of harmonic resonances associated with various cyclotron transitions between Landau states. Polarization dependence of the cross section for the four scattering modes is illustrated and compared with the non-relativistic Thompson cross section with classical widths. Results will find application to various neutron star problems, including computation of Eddington luminosities and polarization mode-switching rates in transient magnetar fireballs.We express our gratitude for the generous support of Michigan Space Grant Consortium, the National Science Foundation (grants AST-0607651, AST-1009725, AST-1009731 and PHY/DMR-1004811), and the

  14. Precision measurement of thermal neutron beam densities using a 3He proportional counter

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage; Bahnsen, A.; Brown, W.K.

    1967-01-01

    A new method, based on the 3He(n, p)T reaction, has been developed for the accurate determination of thermal neutron beam densities. Several comparisons were made with the conventional Au-foil activation method, and agreement was obtained between the two methods within an experimental uncertainty...... of ±0.4%. Fundamental advantages of the method include the 1ν dependence of the 3He(n, p)T cross section up to 1 keV, and the assurance of homogeneity even for very small macroscopic cross sections, because of the gaseous detector material. Although the method requires a relatively clean neutron beam......, it can be used over a wide range of neutron densities and, in particular, is capable of measuring extremely weak beams. A detector has been constructed with a well-defined efficiency and which is able to accept beams of diameters up to 10 cm. The 3He counter method is proposed as a precision standard...

  15. The state-of-the-art of thermal neutron multiplicity counting

    Energy Technology Data Exchange (ETDEWEB)

    Langner, D.G.; Krick, M.S.; Stewart, J.E.; Ensslin, N. [Los Alamos National Lab., NM (United States). Safeguards Science and Technology

    1997-11-01

    Neutron multiplicity counting is a maturing technology. It has been implemented at many facilities to address the increasing need to rapidly measure impure plutonium bearing materials. At Hanford Site and Rocky Flats Environmental Technology Site, multiplicity counting has also been used with excellent results by the International Atomic Energy Agency to verify excess plutonium inventories now under their safeguards. Neutron multiplicity counting as currently implemented, however, will not address all forms of impure plutonium. Materials containing large concentrations of matrix elements like fluorine and beryllium cannot be assayed successfully without extremely long count times. Assays of compact plutonium metals and oxides having a large uranium concentration relative to their plutonium content tend to bias low because of a breakdown in the theoretical model now used to translate the measured multiplicity distributions to plutonium mass. In this paper, the authors will discuss the most recent efforts to extend the range of materials that can be measured successfully with thermal neutron multiplicity counting and a use of multiplicity counting to detect sample changes during long-term storage.

  16. A new method of measuring a large pulsed neutron fluence or dose exploiting the die-away of thermalized neutrons in a polyethylene moderator

    Science.gov (United States)

    Leake, J. W.; Lowe, T.; Mason, R. S.; White, G.

    2010-01-01

    Computer simulations of the response to very short pulses of neutron and gamma radiation of a spherical polyethylene moderator with a central thermal neutron counter and a new, fast, active restore amplifier system have been carried out. A large neutron burst produces count rates in the detector that are too high to measure initially but when the exponential decay of the count rate falls below about 50 k per sec then counting can start. If the counts are recorded in contiguous time intervals (of 60 μs in this case) and the time is measured at which the measured count in an interval falls to 1 or 2 then the size of the initial burst can be calculated. It is shown that it should be possible to measure pulsed neutron ambient dose equivalent H*(10) or dose equivalent rate from about 2 nSv up to about 100 μSv per burst, or 7.2 N μSv s h -1 to 360 N mSv s h -1, where N is the number of neutron bursts per second. The calculations show that a gamma burst of about 10 μGy can be tolerated without affecting the measurement of the largest neutron bursts. This extends our earlier estimate of the maximum dose that can be measured for pulsed neutrons by more than 10 k. This method could also be used to measure the neutron fluence or dose from a single unplanned event such as a beam dump on an accelerator or a criticality incident from fissile material. Although the method described is new it is based on a combination of proven techniques.

  17. 3D neutronic codes coupled with thermal-hydraulic system codes for PWR, and BWR and VVER reactors

    Energy Technology Data Exchange (ETDEWEB)

    Langenbuch, S.; Velkov, K. [GRS, Garching (Germany); Lizorkin, M. [Kurchatov-Institute, Moscow (Russian Federation)] [and others

    1997-07-01

    This paper describes the objectives of code development for coupling 3D neutronics codes with thermal-hydraulic system codes. The present status of coupling ATHLET with three 3D neutronics codes for VVER- and LWR-reactors is presented. After describing the basic features of the 3D neutronic codes BIPR-8 from Kurchatov-Institute, DYN3D from Research Center Rossendorf and QUABOX/CUBBOX from GRS, first applications of coupled codes for different transient and accident scenarios are presented. The need of further investigations is discussed.

  18. Constraints on Thermal X-Ray Radiation from SAX J1808.4-3658 and Implications for Neutron Star Neutrino Emission

    NARCIS (Netherlands)

    C.O. Heinke; P.G. Jonker; R. Wijnands; R.E. Taam

    2007-01-01

    Thermal X-ray radiation from neutron star soft X-ray transients in quiescence provides the strongest constraints on the cooling rates of neutron stars and thus on the interior composition and properties of matter in the cores of neutron stars. We analyze new (2006) and archival (2001) XMM-Newton obs

  19. Semiconductor High-Level Dosimeters Used in the SLAC Mixed Gamma and Neutron Fields

    CERN Document Server

    Mao, S

    2003-01-01

    As part of an exploration of Semiconductor High-Level Dosimetry (SHLD) in the accelerator radiation fields, the response of SHLD system, composed of dual MOSFETs, wide-base PIN diode, and a microprocessor-controlled reader, was calibrated in photon (Co-60) and neutron (Bare-reactor) fields. The response curves for the MOSFET and the PIN diode were determined. The neutron sensitivity of the PIN diode is about a factor of 2200 times higher than its photon sensitivity. Therefore, the PIN diode can be used to measure the neutron dose and virtually ignore the photon dose contribution. The MOSFET can be used to estimate the photon dose after subtracting the ionizing effect of the neutrons. The SHLD was used in the SLAC mixed field to measure the photon and neutron doses around a copper beam dump. The photon measurements near the copper dump agreed reasonably with the FLUKA Monte Carlo calculations. The neutron measurements agreed with FLUKA calculations to within a factor of two.

  20. Time Evolution of Relativistic Force-Free Fields Connecting a Neutron Star and its Disk

    CERN Document Server

    Asano, E; Matsumoto, R; Asano, Eiji; Uchida, Toshio; Matsumoto, Ryoji

    2005-01-01

    We study the magnetic interaction between a neutron star and its disk by solving the time-dependent relativistic force-free equations. At the initial state, we assume that the dipole magnetic field of the neutron star connects the neutron star and its equatorial disk, which deeply enters into the magnetosphere of the neutron star. Magnetic fields are assumed to be frozen to the star and the disk. The rotation of the neutron star and the disk is imposed as boundary conditions. We apply Harten-Lax-van Leer (HLL) method to simulate the evolution of the star-disk system. We carry out simulations for (1) a disk inside the corotation radius, in which the disk rotates faster than the star, and (2) a disk outside the corotation radius, in which the neutron star rotates faster than the disk. Numerical results indicate that for both models, the magnetic field lines connecting the disk and the star inflate as they are twisted by the differential rotation between the disk and the star. When the twist angle exceeds pi rad...