WorldWideScience

Sample records for field test evaluation

  1. Evaluation of field test equipment for halide and DOP testing

    International Nuclear Information System (INIS)

    Schreiber, K.L.; Kovach, J.L.

    1975-01-01

    The Nucon Testing Services Department, field testing at power reactor sites, has performed tests using R-11, R-12, and R-112 in conjunction with gas chromatographs and direct reading halide detectors. The field operational experience with these detector systems, thus sensitivity, precision, and manner of field calibration, are presented. Laboratory experiments regarding 3 H-tagged methyl iodide for in place leak testing of adsorber systems indicate a low hazard, high reliability process for leak testing in facilities where atmospheric cross contamination occurs. (U.S.)

  2. SMART operational field test evaluation : dispatchers survey report : final report

    Science.gov (United States)

    1997-06-01

    The Suburban Mobility Authority for Regional Transportation (SMART) has installed an automaticscheduling and dispatch system (ASD) in Southeast Michigan in accordance with their plans toimplement ITS as a site for an operational field test. The purpo...

  3. SMART operational field test evaluation : scheduler survey report : final report

    Science.gov (United States)

    1997-06-01

    The Suburban Mobility Authority for Regional Transportation (SMART) has installed an automatic scheduling and dispatch system (ASD) in Southeast Michigan in accordance with their plans to implement ITS as a site for an operational field test. The pur...

  4. Personal Radiation Detector Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Chris A. Hodge, Ding Yuan, Raymond P. Keegan, Michael A. Krstich

    2007-01-01

    Following the success of the Anole test of portable detection system, the U.S. Department of Homeland Security (DHS) Domestic Nuclear Detection Office organized a test and evaluation campaign for personal radiation detectors (PRDs), also known as 'Pagers'. This test, 'Bobcat', was conducted from July 17 to August 8, 2006, at the Nevada Test Site. The Bobcat test was designed to evaluate the performance of PRDs under various operational scenarios, such as pedestrian surveying, mobile surveying, cargo container screening, and pedestrian chokepoint monitoring. Under these testing scenarios, many operational characteristics of the PRDs, such as gamma and neutron sensitivities, positive detection and false alarm rates, response delay times, minimum detectable activities, and source localization errors, were analyzed. This paper will present the design, execution, and methodologies used to test this equipment for the DHS

  5. ANOLE Portable Radiation Detection System Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Hodge, Chris A.

    2007-01-01

    Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers the opportunity to submit their equipment for independent operationally relevant testing to subsequently improve their detector performance. This paper will present the design, execution, and methodologies of the DHS Anole portable radiation detection system test campaign

  6. Radiation Isotope Identification Device (RIIDs) Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Christopher Hodge, Raymond Keegan

    2007-01-01

    Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers the opportunity to submit their equipment for independent operationally relevant testing to subsequently improve their detector performance. This paper will present the design, execution, and methodologies of the DHS Anole portable radiation detection system test campaign

  7. Drunk driving warning system (DDWS). Volume 2, Field test evaluation

    Science.gov (United States)

    1983-12-01

    The Drunk Driving Warning System (DDWS) is a vehicle-mounted device for testing driver impairment and activating alarms. The driver must pass a steering competency test (the Critical Tracking Task or CTT) in order to drive the car in a normal manner....

  8. Field test to evaluate colostrum quality in alpaca

    OpenAIRE

    Flodr, Hanna; Wheeler, Jane C.; Krüger D., Paloma; Olazábal L., Juan; Rosadio A., Raúl

    2012-01-01

    Las concentraciones de inmunoglobulinas (Igs) calostrales en la mayoría de especies productivas determinan los niveles de Igs en sus crías, y las fallas en la transferencia pasiva ocasionan susceptibilidades a infecciones en el recién nacido. El presente estudio evaluó dos pruebas de campo (grado de viscosidad visual y uso de refractómetro) para determinar la calidad del calostro de la alpaca en 77 muestras. Asimismo, se determinó la concentración de Igs mediante una prueba de inmunodifusión ...

  9. A Portable Environment Test System: A Field Assessment of Organotin Leachates--Test and Evaluation.

    Science.gov (United States)

    1987-11-01

    of organotin-based antifouling (AF) coatings, NOSC researchers used this facility to study the effects of tributyltin ( TBT ), the primary toxic ...Environmental Test System (PETS) was evaluated with tributyltin ( TBT ) anti oling leachates in Sin Diego Bay over a 7-month period. Overall mean test...EXECUTIVE SUMMARY A Portable Environmental Test System (PETS) was evaluated with tributyltin ( TBT ) antifouling leachates in San Diego Bay for 7

  10. Rapid, high-temperature, field test method for evaluation of geothermal calcium carbonate scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1986-09-01

    A new test method is described that allows the rapid field testing of calcium carbonate scale inhibitors at 500/sup 0/F (260/sup 0/C). The method evolved from use of a full-flow test loop on a well with a mass flow rate of about 1 x 10/sup 6/ lbm/hr (126 kg/s). It is a simple, effective way to evaluate the effectiveness of inhibitors under field conditions. Five commercial formulations were chosen for field evaluation on the basis of nonflowing, laboratory screening tests at 500/sup 0/F (260/sup 0/C). Four of these formulations from different suppliers controlled calcium carbonate scale deposition as measured by the test method. Two of these could dislodge recently deposited scale that had not age-hardened. Performance-profile diagrams, which were measured for these four effective inhibitors, show the concentration interrelationship between brine calcium and inhibitor concentrations at which the formulations will and will not stop scale formation in the test apparatus. With these diagrams, one formulation was chosen for testing on the full-flow brine line. The composition was tested for 6 weeks and showed a dramatic decrease in the scaling occurring at the flow-control valve. This scaling was about to force a shutdown of a major, long-term flow test being done for reservoir economic evaluations. The inhibitor stopped the scaling, and the test was performed without interruption.

  11. Field tests and evaluations of the IAEA Active-Well Coincidence Counter

    International Nuclear Information System (INIS)

    Krick, M.S.; Rinard, P.M.

    1982-12-01

    This report summarizes and evaluates field tests of the Active Well Coincidence Counter (AWCC) at Winfrith and Dounreay, United Kingdom. The applicability of the AWCC for assaying the uranium content of a wide variety of materials was demonstrated and calibration curves were generated. The AWCC was used in three modes (fast, thermal, and passive) while assaying powders, pellets, cartridges, plates, assorted residues, and materials-testing-reactor fuel assemblies

  12. A Bayesian reliability evaluation method with integrated accelerated degradation testing and field information

    International Nuclear Information System (INIS)

    Wang, Lizhi; Pan, Rong; Li, Xiaoyang; Jiang, Tongmin

    2013-01-01

    Accelerated degradation testing (ADT) is a common approach in reliability prediction, especially for products with high reliability. However, oftentimes the laboratory condition of ADT is different from the field condition; thus, to predict field failure, one need to calibrate the prediction made by using ADT data. In this paper a Bayesian evaluation method is proposed to integrate the ADT data from laboratory with the failure data from field. Calibration factors are introduced to calibrate the difference between the lab and the field conditions so as to predict a product's actual field reliability more accurately. The information fusion and statistical inference procedure are carried out through a Bayesian approach and Markov chain Monte Carlo methods. The proposed method is demonstrated by two examples and the sensitivity analysis to prior distribution assumption

  13. Evaluation of field test kits including immunoassays for the detection of contaminants in soil and water

    International Nuclear Information System (INIS)

    Waters, L.C.; Smith, R.R.; Counts, R.W.; Stewart, J.H.; Jenkins, R.A.

    1993-01-01

    Effective field test methods are needed for hazardous waste site characterization and remediation. Useful field methods should be rapid, analyte-specific, cost-effective and accurate in the concentration range at which the analyte is regulated. In this study, field test kits for polychlorinated biphenyls (PCBs), mercury, lead and nitrate were evaluated with reference to these criteria. PCBs and mercury, in soils, were analyzed by immunoassay. Ionic lead and nitrate, in water, were measured chemically using test strips. Except for lead, each analyte was measured in both spiked and actual field samples. Twenty to 40 samples per day can be analyzed with the immunoassays and even more with the strip tests. The sensitivity of the immunoassays is in the 1-3 ppM range. Nitrate was consistently detected at ≥5 ppM; lead ions at ≥20 ppM. Results obtained using these methods compared favorably with those obtained by standard laboratory methods. In addition to being useful field screening methods, these kits can be used in the laboratory to sort out negative samples and/or to define proper dilutions for positive samples requiring further analysis

  14. Shallow geothermal field in Lanzarote (Canary Island). Potential evaluation and heat extraction test

    Energy Technology Data Exchange (ETDEWEB)

    Diez-Gil, J.L.; Valentin, A. [Consejo Superior de Investigaciones Cientificas, Madrid (Spain); Torres, F. [Universidad de Barcelona (Spain); Albert, J.F.

    1994-12-31

    Boreholes were used to perform various experiments. A thermometry was carried out, as well as chemical analysis and an hydrodynamic modelling. This paper presents the scientific aims and conclusions of the whole project called ``Shallow H.D.R. geothermal field`` in Lanzarote (Canary Islands). Potential evaluation and heat extraction test are presented. (Project JOUG-0004 ES -JR - JOULE Program of the EEC). (TEC). 2 tabs.

  15. Sensor design for outdoor racing bicycle field testing for human vibration comfort evaluation

    International Nuclear Information System (INIS)

    Vanwalleghem, Joachim; De Baere, Ives; Van Paepegem, Wim; Loccufier, Mia

    2013-01-01

    This paper is concerned with the vibrational comfort evaluation of the cyclist when cycling a rough surface. Outdoor comfort tests have so far only been done through instrumenting the bicycle with accelerometers. This work instruments a racing bicycle with custom-made contact force sensors and velocity sensors to acquire human comfort through the absorbed power method. Comfort evaluation is assessed at the hand–arm and seat interface of the cyclist with the bicycle. By means of careful finite-element analysis for designing the force gauges at the handlebar and the seat combined with precise calibration of both force and velocity sensors, all sensors have proven to work properly. Initial field tests are focused on the proper functioning of the designed sensors and their suitability for vibration comfort measurements. Tests on a cobblestone road reveal that the outcome of the absorbed power values is within the same range as those from laboratory tests found in the literature. This sensor design approach for outdoor testing with racing bicycles may give a new interpretation on evaluating the cyclist's comfort since the vibrational load is not only quantified in terms of acceleration but also in terms of force and velocity at the bicycle–cyclist contact points. (paper)

  16. Field evaluation of a dual rapid diagnostic test for HIV infection and syphilis in Lima, Peru.

    Science.gov (United States)

    Bristow, Claire C; Leon, Segundo R; Huang, Emily; Brown, Brandon J; Ramos, Lourdes B; Vargas, Silver K; Flores, Juan A; Caceres, Carlos F; Klausner, Jeffrey D

    2016-05-01

    Screening for HIV and syphilis in key populations is recommended by the WHO to reduce the morbidity, mortality and transmission associated with undiagnosed and untreated infections. Rapid point-of-care tests that can detect multiple infections with a single fingerprick whole blood specimen using a single device are gaining popularity. We evaluated the field performance of a rapid dual HIV and syphilis test in people at high risk of HIV and syphilis infections. Participants included men who have sex with men and transgender women recruited in Lima, Peru. Reference standard testing for detection of HIV and syphilis infections, conducted using blood samples from venipuncture, included Treponema pallidum particle agglutination and fourth-generation HIV enzyme immunoassay for which positive results had a confirmation HIV Western blot test. For the evaluation test, SD BIOLINE HIV/Syphilis Duo test (Standard Diagnostics, Korea), a fingerprick blood specimen was used. Sensitivity and specificity were calculated and the exact binomial method was used to determine 95% CIs. A total of 415 participants were recruited for the study. The dual test sensitivity for detection of T. pallidum infection was 89.2% (95% CI 83.5% to 93.5%) and specificity 98.8% (95% CI 96.5% to 99.8%). For detection of HIV infection, the sensitivity of the dual test was 99.1% (95% CI 94.8% to 100%) and specificity 99.4% (95% CI 97.7% to 99.9%). This high performing dual test should be considered for the use in clinical settings to increase uptake of simultaneous testing of HIV and syphilis and accelerate time to treatment for those who need it. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Field test and evaluation of the passive neutron coincidence collar for prototype fast reactor fuel subassemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.; Keddar, A.

    1982-08-01

    The passive neutron Coincidence Collar, which was developed for the verification of plutonium content in fast reactor fuel subassemblies, has been field tested using Prototype Fast Reactor fuel. For passive applications, the system measures the 240 Pu-effective mass from the spontaneous fission rate, and in addition, a self-interrogation technique is used to determine the fissile content in the subassembly. Both the passive and active modes were evaluated at the Windscale Works in the United Kingdom. The results of the tests gave a standard deviation 0.75% for the passive count and 3 to 7% for the active measurement for a 1000-s counting time. The unit will be used in the future for the verification of plutonium in fresh fuel assemblies

  18. Computer-aided dispatch--traffic management center field operational test final evaluation plan : WSDOT deployment

    Science.gov (United States)

    2003-09-22

    This document presents the Evaluation Teams plan for conducting the evaluation of the FOT in Washington State. A companion document exists for the evaluation of the Utah deployment. This plan includes the experimental design for testing hypotheses...

  19. Test plan for the field evaluation and demonstration of the Contamination Control Unit

    International Nuclear Information System (INIS)

    Winberg, M.R.; Thompson, D.N.

    1993-06-01

    This report describes test details of a full demonstration of the Contamination Control Unit (CCU). The CCU is a mobile trailer capable of employing the use of soil fixatives, dust suppression agents, misting, and vacuum systems. These systems can perform a large number of contamination control functions to support the Office of Waste Technology Development (OTD) Buried Waste Integrated Demonstration (BWID) projects, transuranic (TRU) waste retrieval operations, and emergency response for hazardous and radioactive materials incidents. The demonstration will include both performance testing at the North Holmes Laboratory Facility (NHLF) and field testing in conjunction with the Remote Excavation System Demonstration at the Cold Test Pit. The NHLF will test operational parameters using water only, and the field demonstration at the Cold Test Pit involves full scale operation of vacuum, fixant, misting, and dust suppression systems. Test objectives, detailed experimental procedures, and data quality objectives necessary to perform the field demonstration are included in this test plan

  20. Rapid high temperature field test method for evaluation of geothermal calcite scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1982-08-01

    A test method is described which allows the rapid field testing of calcite scale inhibitors in high- temperature geothermal brines. Five commercial formulations, chosen on the basis of laboratory screening tests, were tested in brines with low total dissolved solids at ca 500 F. Four were found to be effective; of these, 2 were found to be capable of removing recently deposited scale. One chemical was tested in the full-flow brine line for 6 wks. It was shown to stop a severe surface scaling problem at the well's control valve, thus proving the viability of the rapid test method. (12 refs.)

  1. Testing the isotropic boundary algorithms method to evaluate the magnetic field configuration in the tail

    International Nuclear Information System (INIS)

    Sergeev, V.A.; Malkov, M.; Mursula, K.

    1993-01-01

    This paper describes tests done on one model system for studying the magnetic field in the magneotail, called the isotropic boundary algorithm method. The tail field lines map into the ionosphere, and there have been two direct methods applied to study tail fields, one a global model, and the other a local model. The global models are so broad in scope that they have a hard time dealing with specific field configurations at some time and some location. Local models rely upon field measurements being simultaneously available over a large region of space to study simultaneously the field configurations. In general this is either very fortuitous or very expensive. The isotropic boundary algorithm method relys upon measuring energetic particles, here protons with energies greater than 30 keV, in the isotropic boundary at low altitudes and interpreting them as representing the boundary between stochastic and adiabatic particle motion regions in the equatorial tail current sheet. The authors have correlated particle measurements by NOAA spacecraft to study the isotropic boundary, with magnetic measurements of tail magnetic fields by the geostationary GOES 2 spacecraft. Positive correlations are observed

  2. Evaluation of initial collector field performance at the Langley Solar Building Test Facility

    Science.gov (United States)

    Boyle, R. J.; Knoll, R. H.; Jensen, R. N.

    1977-01-01

    The thermal performance of the solar collector field for the NASA Langley Solar Building Test Facility is given for October 1976 through January 1977. An 1180 square meter solar collector field with seven collector designs helped to provide hot water for the building heating system and absorption air conditioner. The collectors were arranged in 12 rows with nominally 51 collectors per row. Heat transfer rates for each row are calculated and recorded along with sensor, insolation, and weather data every 5 minutes using a mini-computer. The agreement between the experimental and predicted collector efficiencies was generally within five percentage points.

  3. Field Test and Evaluation of Engineered Biomineralization Technology for Sealing Existing Wells

    Energy Technology Data Exchange (ETDEWEB)

    Cunningham, Alfred [Montana State Univ., Bozeman, MT (United States)

    2015-12-21

    This research project addresses one of the goals of the U.S. Department of Energy (DOE) Carbon Storage Program (CSP) aimed at developing Advanced Wellbore Integrity Technologies to Ensure Permanent Geologic Carbon Storage. The technology field-tested in this research project is referred to as microbially induced calcite precipitation (MICP), which utilizes a biologically-based process to precipitate calcium carbonate. If properly controlled MICP can successfully seal fractures, high permeability zones, and compromised wellbore cement in the vicinity of wellbores and in nearby caprock, thereby improving the storage security of geologically-stored carbon dioxide. This report describes an MICP sealing field test performed on a 24.4 cm (9.625 inch) diameter well located on the Gorgas Steam Generation facility near Jasper, Alabama. The research was aimed at (1) developing methods for delivering MICP promoting fluids downhole using conventional oil field technologies and (2) assessing the ability of MICP to seal cement and formation fractures in the near wellbore region in a sandstone formation. Both objectives were accomplished successfully during a field test performed during the period April 1-11, 2014. The test resulted in complete biomineralization sealing of a horizontal fracture located 340.7 m (1118 feet) below ground surface. A total of 24 calcium injections and six microbial inoculation injections were required over a three day period in order to achieve complete sealing. The fractured region was considered completely sealed when it was no longer possible to inject fluids into the formation without exceeding the initial formation fracture pressure. The test was accomplished using conventional oil field technology including an 11.4 L (3.0 gallon) wireline dump bailer for injecting the biomineralization materials downhole. Metrics indicating successful MICP sealing included reduced injectivity during seal formation, reduction in pressure falloff, and

  4. Flood-Fighting Structures Demonstration and Evaluation Program: Laboratory and Field Testing in Vicksburg, Mississippi

    Science.gov (United States)

    2007-07-01

    then it should be disposed of by recycling or land-filling. This material should not be burned due to the formation of carbon dioxide and carbon...and 2-192). A top spreader bar Chapter 2 Laboratory Testing and Evaluation of Expedient Flood-fighting Barriers 135 Figure 2-189

  5. Field Test Evaluation of Effect on Cone Resistance Caused by Change in Penetration Rate

    DEFF Research Database (Denmark)

    Poulsen, Rikke; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    2012-01-01

    in the laboratory. A change in the measured cone resistance occurs by lowering the penetration rate. This is caused by the changes in drainage conditions. Compared to the normal penetration rate of 20 mm/s, this paper illustrates that lowering the penetration rate leads to an increase in the cone resistance from 1......This paper presents how a change in cone penetration rate affects the measured cone resistance during cone penetration testing in silty soils. Regardless of soil, type the standard rate of penetration is 20 mm/s and it is generally accepted that undrained penetration occurs in clay while drained...... penetration occurs in sand. In intermediate soils such as silty soils, the standard cone penetration rate may result in drainage conditions varying from undrained to partially or fully drained conditions. Field cone penetrations tests have been conducted with different penetration rates on a test site...

  6. Test and evaluation of semiconductor components in mixed field radiation monitoring

    International Nuclear Information System (INIS)

    Cardenas, Jose Patricio N.; Madi Filho, Tufic; Rodrigues, Leticia L.C.

    2009-01-01

    Silicon components have found extensive use in nuclear spectroscopy and counting, as described in many articles in the last three decades. These devices have found utility in radiation dosimetry because a diode, for instance, produces a current approximately 18000 times higher than any ionization chamber of equal sensitive volume. This reduces stringent requirements from the electronics used to amplify or integrate the current and / or allows approaching the ideal detector point for the mapping of radiation fields. For better performance, in the case of diodes, they are normally used with high inverse polarity to obtain a deeper barrier, less noise and shorter transit time. The aim of this work was the evaluation of these semiconductor components for application in ionizing radiation fields monitoring, in nuclear research reactors and radiotherapy facilities, for radiation protection and health physics purposes. Experimental configurations to analyze the performance of commercial semiconductors, such as silicon PIN Photodiodes and Silicon Surface Barrier Detectors, were developed and the performance of three different configurations of charge preamplifier with silicon components was also studied. Components were evaluated for application as neutron detectors, using some types of radiators (converters). The radiation response of these silicon components to neutron fields from nuclear research reactors IEA-R1 and IPEN-MB1 (thermal, epithermal and fast neutrons), from beam holes, experimental halls and AmBe neutron sources in laboratory was investigated. (author)

  7. Evaluation of the Radar Stage Sensor manufactured by Forest Technology Systems—Results of laboratory and field testing

    Science.gov (United States)

    Kunkle, Gerald A.

    2018-01-31

    Two identical Radar Stage Sensors from Forest Technology Systems were evaluated to determine if they are suitable for U.S. Geological Survey (USGS) hydrologic data collection. The sensors were evaluated in laboratory conditions to evaluate the distance accuracy of the sensor over the manufacturer’s specified operating temperatures and distance to water ranges. Laboratory results were compared to the manufacturer’s accuracy specification of ±0.007 foot (ft) and the USGS Office of Surface Water (OSW) policy requirement that water-level sensors have a measurement uncertainty of no more than 0.01 ft or 0.20 percent of the indicated reading. Both of the sensors tested were within the OSW policy requirement in both laboratory tests and within the manufacturer’s specification in the distance to water test over tested distances from 3 to 15 ft. In the temperature chamber test, both sensors were within the manufacturer’s specification for more than 90 percent of the data points collected over a temperature range of –40 to +60 degrees Celsius at a fixed distance of 8 ft. One sensor was subjected to an SDI-12 communication test, which it passed. A field test was conducted on one sensor at a USGS field site near Landon, Mississippi, from February 5 to March 29, 2016. Water-level measurements made by the radar during the field test were in agreement with those made by the Sutron Accubar Constant Flow Bubble Gauge.Upon the manufacturer’s release of updated firmware version 1.09, additional SDI-12 and temperature testing was performed to evaluate added SDI-12 functions and verify that performance was unaffected by the update. At this time, an Axiom data logger is required to perform a firmware update on this sensor. The data confirmed the results of the original test. Based on the test results, the Radar Stage Sensor is a suitable choice for USGS hydrologic data collection.

  8. New test techniques to evaluate near field effects for supersonic store carriage and separation

    Science.gov (United States)

    Sawyer, Wallace C.; Stallings, Robert L., Jr.; Wilcox, Floyd J., Jr.; Blair, A. B., Jr.; Monta, William J.; Plentovich, Elizabeth B.

    1989-01-01

    Store separation and store carriage drag studies were conducted. A primary purpose is to develop new experimental methods to evaluate near field effects of store separation and levels of store carriage drag associated with a variety of carriage techniques for different store shapes and arrangements. Flow field measurements consisting of surface pressure distributions and vapor screen photographs are used to analyze the variations of the store separation characteristics with cavity geometry. Store carriage drag measurements representative of tangent, semi-submerged, and internal carriage installations are presented and discussed. Results are included from both fully metric models and models with only metric segments (metric pallets) and the relative merits of the two are discussed. Carriage drag measurements for store installations on an aircraft parent body are compared both with prediction methods and with installations on a generic parent body.

  9. Evaluation of the rapid plasma reagin "teardrop" card test for screening of syphilis in field conditions.

    Science.gov (United States)

    Van Dyck, E; Van de Velden, L; Ndoye, I; Piot, P; Meheus, A

    1993-01-01

    The availability of simple diagnostic methods may contribute to more efficient control of sexually transmitted diseases (STDs) in developing countries. For the detection of syphilis, a simple rapid plasma reagin (RPR) "teardrop" assay for finger-prick blood samples was developed in 1962. The reliability of this test is compared with RPR, Treponema pallidum hemagglutination assay (TPHA), and fluorescent treponemal antibody absorption (FTA-Abs) assays performed on venous blood samples. To evaluate the potential usefulness of the finger-stick RPR teardrop assay for diagnosis of syphilis in settings with poor medical resources. Pregnant women evaluated at two health centers in Pikine, Senegal were tested for STDs. The RPR teardrop assay was performed on plasma from blood samples obtained by finger prick, and standard RPR, TPHA, and FTA-Abs procedures were performed on serum obtained by vein puncture. The sensitivity and specificity of the finger-prick RPR teardrop assay were 69.7% and 96.5%, respectively, and its reactivity was correlated with RPR serum antibody titer. The finger-prick RPR teardrop assay is not a reliable alternative to the classic serum RPR test.

  10. Field evaluation of a horizontal well recirculation system for groundwater treatment: Pilot test at the Clean Test Site Portsmouth Gaseous Diffusion Plant, Piketon, Ohio

    International Nuclear Information System (INIS)

    Muck, M.T.; Kearl, P.M.; Siegrist, R.L.

    1998-01-01

    This report presents the results of field testing a horizontal well recirculation system at the Portsmouth Gaseous Diffusion Plant (PORTS). The recirculation system uses a pair of horizontal wells, one for groundwater extraction and treatment and the other for reinjection of treated groundwater, to set up a recirculation flow field. The induced flow field from the injection well to the extraction well establishes a sweeping action for the removal and treatment of groundwater contaminants. The overall purpose of this project is to study treatment of mixed groundwater contaminants that occur in a thin water-bearing zone not easily targeted by traditional vertical wells. The project involves several research elements, including treatment-process evaluation, hydrodynamic flow and transport modeling, pilot testing at an uncontaminated site, and pilot testing at a contaminated site. The results of the pilot test at an uncontaminated site, the Clean Test Site (CTS), are presented in this report

  11. An evaluation of corrosion resistant alloys by field corrosion test in Japanese refuse incineration plants

    International Nuclear Information System (INIS)

    Kawahara, Yuuzou; Nakamura, Masanori; Shibuya, Eiichi; Yukawa, Kenichi

    1995-01-01

    As the first step for development of the corrosion resistant superheater tube materials of 500 C, 100 ata used in high efficient waste-to-energy plants, field corrosion tests of six conventional alloys were carried out at metal temperatures of 450 C and 550 C for 700 and 3,000 hours in four typical Japanese waste incineration plants. The test results indicate that austenitic alloys containing approximately 80 wt% [Cr+Ni] show excellent corrosion resistance. When the corrosive environment is severe, intergranular corrosion of 40∼200 microm depth occurs in stainless steel and high alloyed materials. It is confirmed quantitatively that corrosion behavior is influenced by environmental corrosion factors such as Cl concentration and thickness of deposits on tube surface, metal temperature, and flue gas temperature. The excellent corrosion resistance of high [Cr+Ni+Mo] alloys such as Alloy 625 is explained by the stability of its protective oxide, such that the time dependence of corrosion nearly obeys the parabolic rate law

  12. Field Validation of Toxicity Tests to Evaluate the Potential for Beneficial Use of Produced Water

    Energy Technology Data Exchange (ETDEWEB)

    Joseph Bidwell; Jonathan Fisher; Naomi Cooper

    2008-03-31

    This study investigated potential biological effects of produced water contamination derived from occasional surface overflow and possible subsurface intrusion at an oil production site along the shore of Skiatook Lake, Oklahoma. We monitored basic chemistry and acute toxicity to a suite of standard aquatic test species (fathead minnow-Pimephales promelas, Daphnia pulex, Daphnia magna, and Ceriodaphnia dubia) in produced water and in samples taken from shallow groundwater wells on the site. Toxicity identification evaluations and ion toxicity modeling were used to identify toxic constituents in the samples. Lake sediment at the oil production site and at a reference site were also analyzed for brine intrusion chemically and by testing sediment toxicity using the benthic invertebrates, Chironomus dilutus, and Hyallela azteca. Sediment quality was also assessed with in situ survival and growth studies with H. azteca and the Asian clam, Corbicula fluminea, and by benthic macroinvertebrate community sampling. The produced water was acutely toxic to the aquatic test organisms at concentrations ranging from 1% to 10% of the whole produced water sample. Toxicity identification evaluation and ion toxicity modeling indicated major ion salts and hydrocarbons were the primary mixture toxicants. The standardized test species used in the laboratory bioassays exhibited differences in sensitivity to these two general classes of contaminants, which underscores the importance of using multiple species when evaluating produced water toxicity. Toxicity of groundwater was greater in samples from wells near a produced water injection well and an evaporation pond. Principle component analyses (PCA) of chemical data derived from the groundwater wells indicated dilution by lake water and possible biogeochemical reactions as factors that ameliorated groundwater toxicity. Elevated concentrations of major ions were found in pore water from lake sediments, but toxicity from these ions was

  13. Efficacy of the Amsler Grid Test in Evaluating Glaucomatous Central Visual Field Defects.

    Science.gov (United States)

    Su, Daniel; Greenberg, Andrew; Simonson, Joseph L; Teng, Christopher C; Liebmann, Jeffrey M; Ritch, Robert; Park, Sung Chul

    2016-04-01

    To investigate the efficacy of the Amsler grid test in detecting central visual field (VF) defects in glaucoma. Prospective, cross-sectional study. Patients with glaucoma with reliable Humphrey 10-2 Swedish Interactive Threshold Algorithm standard VF on the date of enrollment or within the previous 3 months. Amsler grid tests were performed for each eye and were considered "abnormal" if there was any perceived scotoma with missing or blurry grid lines within the central 10 degrees ("Amsler grid scotoma"). An abnormal 10-2 VF was defined as ≥3 adjacent points at P grid scotoma area were calculated with the 10-2 VF as the clinical reference standard. Among eyes with an abnormal 10-2 VF, regression analyses were performed between the Amsler grid scotoma area and the 10-2 VF parameters (mean deviation [MD], scotoma extent [number of test points with P grid scotoma area. A total of 106 eyes (53 patients) were included (mean ± standard deviation age, 24-2 MD and 10-2 MD = 66±12 years, -9.61±8.64 decibels [dB] and -9.75±9.00 dB, respectively). Sensitivity, specificity, and positive and negative predictive values of the Amsler grid test were 68%, 92%, 97%, and 46%, respectively. Sensitivity was 40% in eyes with 10-2 MD better than -6 dB, 58% in eyes with 10-2 MD between -12 and -6 dB, and 92% in eyes with 10-2 MD worse than -12 dB. The area under the receiver operating characteristic curve of the Amsler grid scotoma area was 0.810 (95% confidence interval, 0.723-0.880, P grid scotoma area had the strongest relationship with 10-2 MD (quadratic R(2)=0.681), followed by 10-2 scotoma extent (quadratic R(2)=0.611) and 10-2 scotoma mean depth (quadratic R(2)=0.299) (all P grid can be used to screen for moderate to severe central vision loss from glaucoma. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  14. Conceptual design for the field test and evaluation of the gas-phase UF6 enrichment meter

    International Nuclear Information System (INIS)

    Strittmatter, R.B.; Leavitt, J.N.; Slice, R.W.

    1980-12-01

    An in-line enrichment monitor is being developed to provide real-time enrichment data for the gas-phase UF 6 feed stream of an enrichment plant. Data from proof-of-principle measurements using a laboratory prototype system are presented. A conceptual design for an enrichment monitor to be field tested and evaluated at the Oak Ridge Gaseous Diffusion Plant is reported

  15. Evaluation of a 3% surf solution (surf field mastitis test) for the diagnosis of subclinical bovine and bubaline mastitis.

    Science.gov (United States)

    Muhammad, Ghulam; Naureen, Abeera; Asi, Muhammad Nadeem; Saqib, Muhammad; Fazal-ur-Rehman

    2010-03-01

    To evaluate a 3% solution of household detergent viz., Surf Excel (Surf field mastitis test, SFMT) vis-à-vis California mastitis test (CMT), Whiteside test (WST), somatic cell counts (SCC; cut off limit = 5 x 10(5) cells per millilitre) and bacteriological cultures for the detection of subclinical mastitis in quarter foremilk samples (n=800) of dairy cows and buffaloes. Culture and SCC were used as gold standards. All tests were evaluated parallel and serial patterns. The sensitivities of SFMT, SCC, culture, CMT and WST in parallel testing were 72.82, 81.55, 87.38, 75.73 and 54.37%, respectively in cows, while 66.22, 79.73, 82.43, 70.27 and 50.00, respectively in buffaloes. SFMT was significantly (pnegative predictive values of SFMT (93.50 in cow; 96.35 in buffaloes) differed non-significantly from that of CMT (94.02 in cow; 96.15 in buffaloes). The kappa index between the tests was moderate to perfect both in parallel (0.54 to >0.80) and serial (0.58 to >0.8) testing. On the basis of closely similar diagnostic efficiency of SFMT to CMT in terms of sensitivity, specificity, predictive values and kappa index together with inexpensive and ready availability of SFMT reagent, it tempting to suggest that SFMT can be use as a cheaper, user-friendly alternative animal-side subclinical mastitis diagnostic test in poor countries.

  16. Field test and evaluation of the IAEA coincidence collar for the measurement of unirradiated BWR fuel assemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.; Keddar, A.

    1982-12-01

    The neutron coincidence counter has been field tested and evaluated for the measurement of boiling-water-reactor (BWR) fuel assemblies at the ASEA-ATOM Fuel Fabrication Facility. The system measures the 235 U content per unit length of full fuel assemblies using neutron interrogation and coincidence counting. The 238 U content is measured in the passive mode without the AmLi neutron interrogatioin source. The field tests included both standard production movable fuel rods to investigate enrichment and absorber variations. Results gave a response standard deviation of 0.9% for the active case and 2.1% for the passive case in 1000-s measurement times. 10 figures, 2 tables

  17. Rationality analysis of field test method for evaluation of geological condition of deposit

    International Nuclear Information System (INIS)

    Huo Jiandang; Wang Ping

    2008-01-01

    The systematical analysis of data obtained is made combined with practical hydrogeology test. The data are treated with computer software for special hydrogeological parameters to obtain hydrogeological parameters at the test zone. Hydrogeological parameters obtained are discussed, the rationality of well pattern employed for hydrogeological test is analyzed, and suggestions are proposed. (authors)

  18. Fostering transfer of web searchers' evaluation skills: A field test of two transfer theories

    NARCIS (Netherlands)

    Walraven, Amber; Brand-Gruwel, Saskia; Boshuizen, Henny P.A.

    2010-01-01

    Transfer of complex cognitive skills is important when stimulating students to become life long learners. An example of a complex cognitive skill is the skill of evaluating results, information and source while solving information problems using the WWW. Especially the knowledge and use of

  19. Test and Evaluation of the Navy Technical Information Presentation System (NTIPS) AN/SPA-25D Field Test Results

    Science.gov (United States)

    1987-12-01

    efficient * and smoothly run test and we are especially grateful for their dedication and support. Finally, Millard Thomas, an engineer with the Display...as a brightened spot ( marker ) on the electronic cursor. Range rings are provided for estimating the range of targets without using the range strobe...asked to express their reactions , for or against, specific TI characteristics, including style, content, format, delivery medium, and, in general, the

  20. SEURAT: Safety Evaluation Ultimately Replacing Animal Testing--recommendations for future research in the field of predictive toxicology.

    Science.gov (United States)

    Daston, George; Knight, Derek J; Schwarz, Michael; Gocht, Tilman; Thomas, Russell S; Mahony, Catherine; Whelan, Maurice

    2015-01-01

    The development of non-animal methodology to evaluate the potential for a chemical to cause systemic toxicity is one of the grand challenges of modern science. The European research programme SEURAT is active in this field and will conclude its first phase, SEURAT-1, in December 2015. Drawing on the experience gained in SEURAT-1 and appreciating international advancement in both basic and regulatory science, we reflect here on how SEURAT should evolve and propose that further research and development should be directed along two complementary and interconnecting work streams. The first work stream would focus on developing new 'paradigm' approaches for regulatory science. The goal here is the identification of 'critical biological targets' relevant for toxicity and to test their suitability to be used as anchors for predicting toxicity. The second work stream would focus on integration and application of new approach methods for hazard (and risk) assessment within the current regulatory 'paradigm', aiming for acceptance of animal-free testing strategies by regulatory authorities (i.e. translating scientific achievements into regulation). Components for both work streams are discussed and may provide a structure for a future research programme in the field of predictive toxicology.

  1. Field testing a soil site field guide for Allegheny hardwoods

    Science.gov (United States)

    S.B. Jones

    1991-01-01

    A site quality evaluation decision model, developed for Allegheny hardwoods on the non-glaciated Allegheny Plateau of Pennsylvania and New York, was field tested by International Paper (IP) foresters and the author, on sites within the region of derivation and on glaciated sites north and west of the Wisconsin drift line. Results from the field testing are presented...

  2. Comparative evaluation of bivalent malaria rapid diagnostic tests versus traditional methods in field with special reference to heat stability testing in Central India.

    Directory of Open Access Journals (Sweden)

    Neeru Singh

    Full Text Available Malaria presents a diagnostic challenge in areas where both Plasmodium falciparum and P.vivax are co-endemic. Bivalent Rapid Diagnostic tests (RDTs showed promise as diagnostic tools for P.falciparum and P.vivax. To assist national malaria control programme in the selection of RDTs, commercially available seven malaria RDTs were evaluated in terms of their performance with special reference to heat stability.This study was undertaken in four forested districts of central India (July, 2011- March, 2012. All RDTs were tested simultaneously in field along with microscopy as gold standard. These RDTs were stored in their original packing at 25°C before transport to the field or they were stored at 35°C and 45°C upto 100 days for testing the performance of RDTs at high temperature. In all 2841 patients with fever were screened for malaria of which 26% were positive for P.falciparum, and 17% for P.vivax. The highest sensitivity of any RDT for P.falciparum was 98% (95% CI; 95.9-98.8 and lowest sensitivity was 76% (95% CI; 71.7-79.6. For P.vivax highest and lowest sensitivity for any RDT was 80% (95% CI; 94.9 - 83.9 and 20% (95% CI; 15.6-24.5 respectively. Heat stability experiments showed that most RDTs for P.falciparum showed high sensitivity at 45°C upto 90 days. While for P.vivax only two RDTs maintained good sensitivity upto day 90 when compared with RDTs kept at room temperature. Agreement between observers was excellent for positive and negative readings for both P.falciparum and P.vivax (Kappa >0.6-0.9.This is first field evaluation of RDTs regarding their temperature stability. Although RDTs are useful as diagnostic tool for P.falciparum and P.vivax even at high temperature, the quality of RDTs should be regulated and monitored more closely.

  3. Ten years later: Evaluation of the effectiveness of 12.5% amitraz against a field population of Rhipicephalus (Boophilus) microplus using field studies, artificial infestation (Stall tests) and adult immersion tests.

    Science.gov (United States)

    Maciel, Willian Giquelin; Lopes, Welber Daniel Zanetti; Cruz, Breno Cayeiro; Gomes, Lucas Vinicius Costa; Teixeira, Weslen Fabrício Pires; Buzzulini, Carolina; Bichuette, Murilo Abud; Campos, Gabriel Pimentel; Felippelli, Gustavo; Soares, Vando Edésio; de Oliveira, Gilson Pereira; da Costa, Alvimar José

    2015-12-15

    Using field trials, artificial infestations (Stall tests) and in vitro adult immersion tests, the present study evaluated the acaricidal efficacy of 12.5% amitraz administered via whole body spraying against a Rhipicephalus (Boophilus) microplus population that did not have any contact with chemical products belonging to this acaricide family for 10 years (approximately 40 generations). Two natural infestation trials, two artificial infestation trials (Stall tests) and two adult immersion tests were performed in two different stages in 2005 and 2015. Between 2002 and 2015, the bovine herd of this property was formed by approximately 450 animals from the Simmental breed that were divided into nine paddocks formed by Cynodon dactylon (L.) Pers. For the natural infestation experiments in 2005 and 2015, we selected nearly 70 animals naturally infested with ticks from the same herd that belonged to the "São Paulo" farm located in São José do Rio Pardo, São Paulo, Brazil. Field studies were performed in the same paddock (9). To evaluate anti-R. (B.) microplus activity in the artificially infested cattle (Stall tests) and adult immersion tests, two experiments of each methodology were performed at CPPAR (the Center of Research in Animal Health located on the FCAV/UNESP campus in Jaboticabal, São Paulo, Brazil) in 2005 and 2015. R. (B.) microplus used in the artificial infestation, and adult immersion test experiments were obtained from paddocks 1-9 in 2005 and 2015 from the commercial farm where the field studies were performed. Based on the obtained results, it was possible to conclude that amitraz use in rotation with pyrethroids every 28 days for three consecutive years (2002-2004) previous to the beginning of the first trial (2005) was sufficient to generate a R. (B.) microplus strain resistant to amitraz. Moreover, using field trials, artificial infestations (Stall tests) and adult immersion tests, we verified that 40 generations of the tick species with no

  4. Integrated field and laboratory tests to evaluate effects of metals-impacted wetlands on amphibians: A case study from Montana

    Science.gov (United States)

    Linder, G.; ,

    2003-01-01

    Mining activities frequently impact wildlife habitats, and a wide range of habitats may require evaluations of the linkages between wildlife and environmental stressors common to mining activities (e.g., physical alteration of habitat, releases of chemicals such as metals and other inorganic constituents as part of the mining operation). Wetlands, for example, are frequently impacted by mining activities. Within an ecological assessment for a wetland, toxicity evaluations for representative species may be advantageous to the site evaluation, since these species could be exposed to complex chemical mixtures potentially released from the site. Amphibian species common to these transition zones between terrestrial and aquatic habitats are one key biological indicator of exposure, and integrated approaches which involve both field and laboratory methods focused on amphibians are critical to the assessment process. The laboratory and field evaluations of a wetland in western Montana illustrates the integrated approach to risk assessment and causal analysis. Here, amphibians were used to evaluate the potential toxicity associated with heavy metal-laden sediments deposited in a reservoir. Field and laboratory methods were applied to a toxicity assessment for metals characteristic of mine tailings to reduce potential "lab to field" extrapolation errors and provide adaptive management programs with critical site-specific information targeted on remediation.

  5. SEURAT: Safety Evaluation Ultimately Replacing Animal Testing – Recommendations for future research in the field of predictive toxicology

    Science.gov (United States)

    The development of non-animal methodology to evaluate the potential for a chemical to cause systemic toxicity is one of the grand challenges of modern science. The European research programme SEURAT is active in this field and will conclude its first phase, SEURAT-1, in December ...

  6. Evaluation of Visual Field Test Parameters after Artificial Tear Administration in Patients with Glaucoma and Dry Eye.

    Science.gov (United States)

    Özyol, Pelin; Özyol, Erhan; Karalezli, Aylin

    2018-01-01

    To examine the effect of a single dose of artificial tear administration on automated visual field (VF) testing in patients with glaucoma and dry eye syndrome. A total of 35 patients with primary open-angle glaucoma experienced in VF testing with symptoms of dry eye were enrolled in this study. At the first visit, standard VF testing was performed. At the second and third visits with an interval of one week, while the left eyes served as control, one drop of artificial tear was administered to each patient's right eye, and then VF testing was performed again. The reliability parameters, VF indices, number of depressed points at probability levels of pattern deviation plots, and test times were compared between visits. No significant difference was observed in any VF testing parameters of control eyes (P>0.05). In artificial tear administered eyes, significant improvement was observed in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2) of pattern deviation plots (P˂0.05). The post-hoc test revealed that artificial tear administration elicited an improvement in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2%) of pattern deviation plots from first visit to second and third visits (P˂0.01, for all comparisons). The intraclass correlation coefficient for the three VF test indices was found to be between 0.735 and 0.85 (P<0.001, for all). A single dose of artificial tear administration immediately before VF testing seems to improve test results and decrease test time.

  7. Comparative evaluation of two rapid field tests for malaria diagnosis: Partec Rapid Malaria Test® and Binax Now® Malaria Rapid Diagnostic Test.

    Science.gov (United States)

    Nkrumah, Bernard; Acquah, Samuel Ek; Ibrahim, Lukeman; May, Juergen; Brattig, Norbert; Tannich, Egbert; Nguah, Samuel Blay; Adu-Sarkodie, Yaw; Huenger, Frank

    2011-05-23

    About 90% of all malaria deaths in sub-Saharan Africa occur in children under five years. Fast and reliable diagnosis of malaria requires confirmation of the presence of malaria parasites in the blood of patients with fever or history suggestive of malaria; hence a prompt and accurate diagnosis of malaria is the key to effective disease management. Confirmation of malaria infection requires the availability of a rapid, sensitive, and specific testing at an affordable cost. We compared two recent methods (the novel Partec Rapid Malaria Test® (PT) and the Binax Now® Malaria Rapid Diagnostic Test (BN RDT) with the conventional Giemsa stain microscopy (GM) for the diagnosis of malaria among children in a clinical laboratory of a hospital in a rural endemic area of Ghana. Blood samples were collected from 263 children admitted with fever or a history of fever to the pediatric clinic of the Agogo Presbyterian Hospital. The three different test methods PT, BN RDT and GM were performed independently by well trained and competent laboratory staff to assess the presence of malaria parasites. Results were analyzed and compared using GM as the reference standard. In 107 (40.7%) of 263 study participants, Plasmodium sp. was detected by GM. PT and BN RDT showed positive results in 111 (42.2%) and 114 (43.4%), respectively. Compared to GM reference standard, the sensitivities of the PT and BN RDT were 100% (95% CI: 96.6-100) and 97.2% (95% CI: 92.0-99.4), respectively, specificities were 97.4% (95% CI: 93.6-99.3) and 93.6% (95% CI: 88.5-96.9), respectively. There was a strong agreement (kappa) between the applied test methods (GM vs PT: 0.97; p < 0.001 and GM vs BN RDT: 0.90; p < 0.001). The average turnaround time per tests was 17 minutes. In this study two rapid malaria tests, PT and BN RDT, demonstrated a good quality of their performance compared to conventional GM. Both methods require little training, have short turnaround times, are applicable as well as affordable and

  8. Design standards for experimental and field studies to evaluate diagnostic accuracy of tests for infectious diseases in aquatic animals.

    Science.gov (United States)

    Laurin, E; Thakur, K K; Gardner, I A; Hick, P; Moody, N J G; Crane, M S J; Ernst, I

    2018-05-01

    Design and reporting quality of diagnostic accuracy studies (DAS) are important metrics for assessing utility of tests used in animal and human health. Following standards for designing DAS will assist in appropriate test selection for specific testing purposes and minimize the risk of reporting biased sensitivity and specificity estimates. To examine the benefits of recommending standards, design information from published DAS literature was assessed for 10 finfish, seven mollusc, nine crustacean and two amphibian diseases listed in the 2017 OIE Manual of Diagnostic Tests for Aquatic Animals. Of the 56 DAS identified, 41 were based on field testing, eight on experimental challenge studies and seven on both. Also, we adapted human and terrestrial-animal standards and guidelines for DAS structure for use in aquatic animal diagnostic research. Through this process, we identified and addressed important metrics for consideration at the design phase: study purpose, targeted disease state, selection of appropriate samples and specimens, laboratory analytical methods, statistical methods and data interpretation. These recommended design standards for DAS are presented as a checklist including risk-of-failure points and actions to mitigate bias at each critical step. Adherence to standards when designing DAS will also facilitate future systematic review and meta-analyses of DAS research literature. © 2018 John Wiley & Sons Ltd.

  9. Small wind turbine performance evaluation using field test data and a coupled aero-electro-mechanical model

    Science.gov (United States)

    Wallace, Brian D.

    A series of field tests and theoretical analyses were performed on various wind turbine rotor designs at two Penn State residential-scale wind-electric facilities. This work involved the prediction and experimental measurement of the electrical and aerodynamic performance of three wind turbines; a 3 kW rated Whisper 175, 2.4 kW rated Skystream 3.7, and the Penn State designed Carolus wind turbine. Both the Skystream and Whisper 175 wind turbines are OEM blades which were originally installed at the facilities. The Carolus rotor is a carbon-fiber composite 2-bladed machine, designed and assembled at Penn State, with the intent of replacing the Whisper 175 rotor at the off-grid system. Rotor aerodynamic performance is modeled using WT_Perf, a National Renewable Energy Laboratory developed Blade Element Momentum theory based performance prediction code. Steady-state power curves are predicted by coupling experimentally determined electrical characteristics with the aerodynamic performance of the rotor simulated with WT_Perf. A dynamometer test stand is used to establish the electromechanical efficiencies of the wind-electric system generator. Through the coupling of WT_Perf and dynamometer test results, an aero-electro-mechanical analysis procedure is developed and provides accurate predictions of wind system performance. The analysis of three different wind turbines gives a comprehensive assessment of the capability of the field test facilities and the accuracy of aero-electro-mechanical analysis procedures. Results from this study show that the Carolus and Whisper 175 rotors are running at higher tip-speed ratios than are optimum for power production. The aero-electro-mechanical analysis predicted the high operating tip-speed ratios of the rotors and was accurate at predicting output power for the systems. It is shown that the wind turbines operate at high tip-speeds because of a miss-match between the aerodynamic drive torque and the operating torque of the wind

  10. Field Evaluation of a High Throughput Loop Mediated Isothermal Amplification Test for the Detection of Asymptomatic Plasmodium Infections in Zanzibar.

    Directory of Open Access Journals (Sweden)

    Berit Aydin-Schmidt

    Full Text Available New field applicable diagnostic tools are needed for highly sensitive detection of residual malaria infections in pre-elimination settings. Field performance of a high throughput DNA extraction system for loop mediated isothermal amplification (HTP-LAMP was therefore evaluated for detecting malaria parasites among asymptomatic individuals in Zanzibar.HTP-LAMP performance was evaluated against real-time PCR on 3008 paired blood samples collected on filter papers in a community-based survey in 2015.The PCR and HTP-LAMP determined malaria prevalences were 1.6% (95%CI 1.3-2.4 and 0.7% (95%CI 0.4-1.1, respectively. The sensitivity of HTP-LAMP compared to PCR was 40.8% (CI95% 27.0-55.8 and the specificity was 99.9% (CI95% 99.8-100. For the PCR positive samples, there was no statistically significant difference between the geometric mean parasite densities among the HTP-LAMP positive (2.5 p/μL, range 0.2-770 and HTP-LAMP negative (1.4 p/μL, range 0.1-7 samples (p = 0.088. Two lab technicians analysed up to 282 samples per day and the HTP-LAMP method was experienced as user friendly.Although field applicable, this high throughput format of LAMP as used here was not sensitive enough to be recommended for detection of asymptomatic low-density infections in areas like Zanzibar, approaching malaria elimination.

  11. Evaluation of the Field Performance of ImmunoCard STAT!® Rapid Diagnostic Test for Rotavirus in Dadaab Refugee Camp and at the Kenya-Somalia Border.

    Science.gov (United States)

    Ope, Maurice; Nyoka, Raymond; Unshur, Ahmed; Oyier, Fredrick O; Mowlid, Shafe A; Owino, Brian; Ochieng, Steve B; Okello, Charles I; Montgomery, Joel M; Wagacha, Burton; Galev, Aleksandar; Abdow, Abdikadir; Esona, Mathew D; Tate, Jacqueline; Fitter, David; Cookson, Susan T; Arunmozhi, Balajee; Marano, Nina

    2017-06-01

    AbstractRotavirus commonly causes diarrhea in children, leading to hospitalization and even death. Rapid diagnostic tests are feasible alternatives for determining rotavirus outbreaks in refugee camps that have inadequate laboratory capacity. We evaluated the field performance of ImmunoCard STAT! ® Rotavirus (ICS-RV) in Dadaab Refugee Camp and at the Kenya-Somalia border. From May to December 2014, we prospectively enrolled children aged < 5 years hospitalized with acute diarrhea, defined as ≥ 3 episodes of loose stool in 24 hours for < 7 days. Stool samples were collected and tested by trained surveillance clerks using ICS-RV per manufacturer's instructions. The field performance characteristics of ICS-RV were evaluated against the gold standard test, Premier ™ Rotaclone ® enzyme immunoassay. The operational characteristics were evaluated using World Health Organization (WHO) ASSURED criteria to determine whether ICS-RV is appropriate as a point-of-care test by administering a standard questionnaire and observing surveillance clerks performing the test. We enrolled 213 patients with a median age of 10 months (range = 1-48); 58.2% were male. A total of 71 (33.3%) and 60 (28.2%) patients tested positive for rotavirus infection by immunoassay and ICS-RV, respectively. The sensitivity, specificity, and positive and negative predictive values of ICS-RV compared with the immunoassay were 83.1% (95% confidence interval [CI] = 72.3-91.0), 99.3% (95% CI = 96.1-100), 98.3% (95% CI = 91.1-100), and 92.1% (95% CI = 86.6-95.5), respectively. The ICS-RV fulfilled the WHO ASSURED criteria for point-of-care testing. ICS-RV is a field-ready point-of-care test with good field performance and operational characteristics. It can be useful in determining rotavirus outbreaks in resource-limited settings.

  12. Field evaluation of two point-of-care tests for syphilis among men who have sex with men, Verona, Italy.

    Science.gov (United States)

    Zorzi, Antonella; Cordioli, Maddalena; Gios, Lorenzo; Del Bravo, Paola; Toskin, Igor; Peeling, Rosanna W; Blondeel, Karel; Cornaglia, Giuseppe; Kiarie, James; Ballard, Ronald; Mirandola, Massimo

    2017-12-01

    The incidence of HIV and syphilis among men who have sex with men (MSM) in Europe has recently increased. Rapid point-of-care tests (POCTs) for syphilis can improve access to screening. The purpose of this study was to evaluate the performance of two syphilis POCTs compared with laboratory tests among MSM. The study was undertaken in Verona, Italy. Asymptomatic MSM, potentially exposed to syphilis, were enrolled prospectively. The POCTs evaluated were SD Bioline Syphilis 3.0 and Chembio DPP Syphilis Screen & Confirm Assay on both serum and fingerprick blood. The results of the POCTs were read by the naked eye by two independent readers and their concordance assessed. A total of 289 MSM were enrolled in the study. Based on laboratory tests, 35 MSM (12.1%) were TPPA-positive alone and 16 (5.5%) were both Treponema pallidum particle agglutination test (TPPA) and rapid plasma reagin (RPR)-positive. The specificities of both POCTs were above 99% on both serum and fingerstick blood specimens, while sensitivities varied considerably. The sensitivity of the SD Bioline test was lower on fingerprick blood (51.4% and 54.3%, readers 1 and 2, respectively) compared with that on serum (80.0% and 82.9%). In contrast, the Chembio test exhibited similar sensitivity values for serum and fingerprick samples (57.7% and 64.0% on serum vs 65.4% and 69.2% on fingerprick for the treponemal component; 63.6% on both samples by both readers for the non-treponemal component). The positive predictive value ranged between 100% and 93.9% for the treponemal component of both syphilis POCTs, but was lower (76.3%-100%)%) for the non-treponemal component of the Chembio POCT. The negative predictive value surpassed 90% for both tests on both samples. The agreement between readers was very high (>99%). The diagnostic performance of the syphilis POCTs was lower than expected; however, considering the prevalence of syphilis among MSM, POCTs should be recommended to improve syphilis detection among MSM

  13. Field Test Evaluation of Conservation Retrofits of Low-Income Single Family Buildings in Wisconsin: Summary Report; TOPICAL

    International Nuclear Information System (INIS)

    Ternes, M.P.

    2001-01-01

    During the winter of 1985-86, a retrofit field test was performed in 66 occupied, low-income, single-family homes in Madison, Wisconsin. The primary objectives of the field test were to (1) determine the measured energy savings and the relative benefits of a combination of envelope and mechanical equipment retrofits that were selected following a new audit-directed retrofit procedure, (2) determine the energy savings and benefits due to performing infiltration reduction work following a recently developed infiltration reduction procedure, and (3) study general occupant behavior and house thermal characteristics and their possible change following retrofit installation. This report provides an overview of the project and summarizes the findings which will be presented in detail in separate reports. Major findings from the field test include: (1) The audit-directed retrofit procedure produced an average savings of 207 therms/year/house. The procedure also more than doubled the overall cost-effectiveness of the low-income weatherization assistance program as compared with the priority system formerly used in Wisconsin. Wall insulation and condensing furnaces were the major retrofits (predicted annual energy savings greater than 100 therms/year) most often selected under the procedure. The respective average energy savings of the houses receiving wall insulation and condensing furnace. s was 14.6 and 14.3 therms/year for each$100 spent on them under the program. (2) The blower-door-guided infiltration reduction procedure reduced expenditures for infiltration reduction to about one-fourth of previous program costs (from$570/house to$106/house). The procedure also reduced the average air leakage rate in the treated houses by 16%, whereas, in a previous study, no significant reduction was found following the installation of typical infiltration reduction measures. (3) Twenty to 60% of the deviation between predicted and measured savings can be attributed to incorrect

  14. Open-field test site

    Science.gov (United States)

    Gyoda, Koichi; Shinozuka, Takashi

    1995-06-01

    An open-field test site with measurement equipment, a turn table, antenna positioners, and measurement auxiliary equipment was remodelled at the CRL north-site. This paper introduces the configuration, specifications and characteristics of this new open-field test site. Measured 3-m and 10-m site attenuations are in good agreement with theoretical values, and this means that this site is suitable for using 3-m and 10-m method EMI/EMC measurements. The site is expected to be effective for antenna measurement, antenna calibration, and studies on EMI/EMC measurement methods.

  15. SRS environmental technology development field test platform

    International Nuclear Information System (INIS)

    Riha, B.D.; Rossabi, J.; Eddy-Dilek, C.A.

    1995-01-01

    A critical and difficult step in the development and implementation of new technologies for environmental monitoring and characterization is successfully transferring these technologies to industry and government users for routine assessment and compliance activities. The Environmental Sciences Section of the DOE Savannah River Technology Center provides a forum for developers, potential users, and regulatory organizations to evaluate new technologies in comparison with baseline technologies in a well characterized field test bed. The principal objective of this project is to conduct comprehensive, objective field tests of monitoring and characterization technologies that are not currently used in EPA standard methods and evaluate their performance during actual operating conditions against baseline methods. This paper provides an overview of the field test site and a description of some of the technologies demonstrated at the site including their field applications

  16. Useful field of view test.

    Science.gov (United States)

    Wood, Joanne M; Owsley, Cynthia

    2014-01-01

    The useful field of view test was developed to reflect the visual difficulties that older adults experience with everyday tasks. Importantly, the useful field of view test (UFOV) is one of the most extensively researched and promising predictor tests for a range of driving outcomes measures, including driving ability and crash risk as well as other everyday tasks. Currently available commercial versions of the test can be administered using personal computers; these measure the speed of visual processing for rapid detection and localization of targets under conditions of divided visual attention and in the presence and absence of visual clutter. The test is believed to assess higher-order cognitive abilities, but performance also relies on visual sensory function because in order for targets to be attended to, they must be visible. The format of the UFOV has been modified over the years; the original version estimated the spatial extent of useful field of view, while the latest version measures visual processing speed. While deficits in the useful field of view are associated with functional impairments in everyday activities in older adults, there is also emerging evidence from several research groups that improvements in visual processing speed can be achieved through training. These improvements have been shown to reduce crash risk, and can have a positive impact on health and functional well-being, with the potential to increase the mobility and hence the independence of older adults. © 2014 S. Karger AG, Basel

  17. Performance Evaluation of Advanced Retrofit Roof Technologies Using Field-Test Data Phase Three Final Report, Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, Kaushik [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Phillip W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    This article presents some miscellaneous data from two low-slope and two steep-slope experimental roofs. The low-slope roofs were designed to compare the performance of various roof coatings exposed to natural weatherization. The steep-slope roofs contained different combinations of phase change material, rigid insulation, low emittance surface and above-sheathing ventilation, with standing-seam metal panels on top. The steep-slope roofs were constructed on a series of adjacent attics separated at the gables using thick foam insulation. This article describes phase three (3) of a study that began in 2009 to evaluate the energy benefits of a sustainable re-roofing technology utilizing standing-seam metal roofing panels combined with energy efficient features like above-sheathing-ventilation (ASV), phase change material (PCM) and rigid insulation board. The data from phases 1 and 2 have been previously published and reported [Kosny et al., 2011; Biswas et al., 2011; Biswas and Childs, 2012; Kosny et al., 2012]. Based on previous data analyses and discussions within the research group, additional test roofs were installed in May 2012, to test new configurations and further investigate different components of the dynamic insulation systems. Some experimental data from phase 3 testing from May 2012 to December 2013 and some EnergyPlus modeling results have been reported in volumes 1 and 3, respectively, of the final report [Biswas et al., 2014; Biswas and Bhandari, 2014].

  18. Prototype Engineered Barrier System Field Tests

    International Nuclear Information System (INIS)

    Ramirez, A.L.; Beatty, J.; Buscheck, T.A.

    1989-01-01

    This paper presents selected preliminary results obtained during the first 54 days of the Prototype Engineered Barrier System Field Tests (PEBSFT) that are being performed in G-Tunnel within the Nevada Test Site. The test described is a precursor to the Engineered Barrier Systems Field Tests (EBSFT). The EBSFT will consist of in situ tests of the geohydrologic and geochemical environment in the near field (within a few meters) of heaters emplaced in welded tuff to simulate the thermal effects of waste packages. The PEBSFTs are being conducted to evaluate the applicability of measurement techniques, numerical models, and procedures for future investigations that will be conducted in the Exploratory Shaft Facilities of the Yucca Mountain Project (YMP). The paper discusses the evolution of hydrothermal behavior during the prototype test, including rock temperatures, changes in rock moisture content, air permeability of fractures, gas pressures, and rock mass gas-phase humidity. 10 refs., 12 figs

  19. Evaluation of the salt deposition on the canister surface of concrete cask. Part 2. Measurement test of the salt concentration in air and salt deposition in the field

    International Nuclear Information System (INIS)

    Wataru, Masumi

    2012-01-01

    Concerning the storage facility of spent nuclear fuel using the concrete cask, there is an issue of stress corrosion cracking(SCC). The cooling air goes up along the canister surface in the concrete cask. To evaluate the initiation of SCC or rusting, it is important to verify the estimation method of the sea salt deposition on the metal canister surface transported by cooling air including sea salt particles. To measure the deposition rate, field tests were performed in Choushi test center. In the field test, it was found that the amount of sea salt deposition was very low because the density of the atmospheric sea salt concentration was very low compared with the laboratory test. Using relation between laboratory data and filed data, it is possible to evaluate the salt deposition rate on the canister surface. We also measured atmospheric sea salt concentration in Choushi test center to make the environment condition clear and compared the measurement data with the calculation data to verify the evaluation model. We are developing the automatic measuring device for atmospheric sea salt concentration. To check its performance, we are measuring atmospheric sea salt concentration in Yokosuka Area of CRIEPI and it was confirmed that the device works for one month automatically and fulfills its specifications. (author)

  20. Survey report for fiscal 1999. Evaluation and analysis on items applied for in high-performance industrial furnace introduction field test project in fiscal 1999; 1999 nendo koseino kogyoro donyu field test jigyo chosa hokokusho. Obo anken hyoka bunseki

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    This paper describes comprehensive evaluation and analysis mainly on the 51 items adopted in the high-performance industrial furnace introduction field tests. The development of a high-performance industrial furnace has completed the fundamental development research in fiscal 1998, and the possibility was verified on energy saving of more than 30% and reduction of NOx emission by 50% over that by conventional furnaces. Upon this fundamental achievement, the field test project has started as the comprehensive approach to developing the practically usable technologies for three years from fiscal 1998 until fiscal 2000, which is being promoted as a joint research project. According to the survey on the actual state in fiscal 1998, a little less than 20,000 industrial furnaces having combustion capacity of more than 500,000 Kcal/hr (excepting boilers) are being used. If these furnaces are converted into the high-performance industrial furnace, energy conservation of 210,000 x 10{sup 6} Mcal (converted to crude oil of 22.7 x 10{sup 6} kl/year) can be achieved from the maximum annual energy consumption of 700,000 x 10{sup 6} Mcal (converted to crude oil of 75.7 x 10{sup 6} kl/year). This conservation amount corresponds to about 12% of the final energy consumption in the whole Japanese industrial departments in fiscal 1996. It is expected that the performance of the full-size high-performance industrial furnace will be verified, and this technology will be promoted for wide proliferation. (NEDO)

  1. Proficiency tests, Evaluating

    NARCIS (Netherlands)

    Cofino, W.P.; Molenaar, J.; Torfs, P.J.J.F.

    2017-01-01

    Marine monitoring programs provide data that are essential for marine management. The reliability of such data is underpinned by proficiency tests. In the context of Quasimeme, a proficiency testing program for the marine environment, a statistical model has been developed in 2000 to evaluate data

  2. Field Evaluation of a Coproantigen Detection Test for Fascioliasis Diagnosis and Surveillance in Human Hyperendemic Areas of Andean Countries

    Science.gov (United States)

    Valero, María Adela; Periago, María Victoria; Pérez-Crespo, Ignacio; Angles, René; Villegas, Fidel; Aguirre, Carlos; Strauss, Wilma; Espinoza, José R.; Herrera, Patricia; Terashima, Angelica; Tamayo, Hugo; Engels, Dirk; Gabrielli, Albis Francesco; Mas-Coma, Santiago

    2012-01-01

    Background Emergence of human fascioliasis prompted a worldwide control initiative including a pilot study in a few countries. Two hyperendemic areas were chosen: Huacullani, Northern Altiplano, Bolivia, representing the Altiplanic transmission pattern with high prevalences and intensities; Cajamarca valley, Peru, representing the valley pattern with high prevalences but low intensities. Coprological sample collection, transport and study procedures were analyzed to improve individual diagnosis and subsequent treatments and surveillance activities. Therefore, a coproantigen-detection technique (MM3-COPRO ELISA) was evaluated, using classical techniques for egg detection for comparison. Methodology and Findings A total of 436 and 362 stool samples from schoolchildren of Huacullani and Cajamarca, respectively, were used. Positive samples from Huacullani were 24.77% using the MM3-COPRO technique, and 21.56% using Kato-Katz. Positive samples from Cajamarca were 11.05% using MM3-COPRO, and 5.24% using rapid sedimentation and Kato-Katz. In Huacullani, using Kato-Katz as gold standard, sensitivity and specificity were 94.68% and 98.48%, respectively, and using Kato-Katz and COPRO-ELISA test together, they were 95.68% and 100%. In Cajamarca, using rapid sedimentation and Kato-Katz together, results were 94.73% and 93.58%, and using rapid sedimentation, Kato-Katz and copro-ELISA together, they were 97.56% and 100%, respectively. There was no correlation between coproantigen detection by optical density (OD) and infection intensity by eggs per gram of feces (epg) in Cajamarca low burden cases (<400 epg), nor in Huacullani high burden cases (≥400 epg), although there was in Huacullani low burden cases (<400 epg). Six cases of egg emission appeared negative by MM3-COPRO, including one with a high egg count (1248 epg). Conclusions The coproantigen-detection test allows for high sensitivity and specificity, fast large mass screening capacity, detection in the chronic phase

  3. Field evaluation of a coproantigen detection test for fascioliasis diagnosis and surveillance in human hyperendemic areas of Andean countries.

    Directory of Open Access Journals (Sweden)

    María Adela Valero

    Full Text Available Emergence of human fascioliasis prompted a worldwide control initiative including a pilot study in a few countries. Two hyperendemic areas were chosen: Huacullani, Northern Altiplano, Bolivia, representing the Altiplanic transmission pattern with high prevalences and intensities; Cajamarca valley, Peru, representing the valley pattern with high prevalences but low intensities. Coprological sample collection, transport and study procedures were analyzed to improve individual diagnosis and subsequent treatments and surveillance activities. Therefore, a coproantigen-detection technique (MM3-COPRO ELISA was evaluated, using classical techniques for egg detection for comparison.A total of 436 and 362 stool samples from schoolchildren of Huacullani and Cajamarca, respectively, were used. Positive samples from Huacullani were 24.77% using the MM3-COPRO technique, and 21.56% using Kato-Katz. Positive samples from Cajamarca were 11.05% using MM3-COPRO, and 5.24% using rapid sedimentation and Kato-Katz. In Huacullani, using Kato-Katz as gold standard, sensitivity and specificity were 94.68% and 98.48%, respectively, and using Kato-Katz and COPRO-ELISA test together, they were 95.68% and 100%. In Cajamarca, using rapid sedimentation and Kato-Katz together, results were 94.73% and 93.58%, and using rapid sedimentation, Kato-Katz and copro-ELISA together, they were 97.56% and 100%, respectively. There was no correlation between coproantigen detection by optical density (OD and infection intensity by eggs per gram of feces (epg in Cajamarca low burden cases (<400 epg, nor in Huacullani high burden cases (≥ 400 epg, although there was in Huacullani low burden cases (<400 epg. Six cases of egg emission appeared negative by MM3-COPRO, including one with a high egg count (1248 epg.The coproantigen-detection test allows for high sensitivity and specificity, fast large mass screening capacity, detection in the chronic phase, early detection of treatment failure

  4. Remote field eddy current testing

    International Nuclear Information System (INIS)

    Cheong, Y. M.; Jung, H. K.; Huh, H.; Lee, Y. S.; Shim, C. M.

    2001-03-01

    The state-of-art technology of the remote field eddy current, which is actively developed as an electromagnetic non-destructive testing tool for ferromagnetic tubes, is described. The historical background and recent R and D activities of remote-field eddy current technology are explained including the theoretical development of remote field eddy current, such as analytical and numerical approach, and the results of finite element analysis. The influencing factors for actual applications, such as the effect of frequency, magnetic permeability, receiving sensitivity, and difficulties of detection and classification of defects are also described. Finally, two examples of actual application, 1) the gap measurement between pressure tubes and calandria tube in CANDU reactor and, 2) the detection of defects in the ferromagnetic heat exchanger tubes, are described. The future research efforts are also included

  5. Evaluate existing radiation fields

    International Nuclear Information System (INIS)

    Aldrich, J.M.; Haggard, D.L.; Endres, G.W.R.; Fix, J.J.

    1981-01-01

    Knowledge of the spectrum of energies for beta, gamma, and neutron radiation experienced in the field is crucial to the proper interpretation of personnel dose. Calibration sources and techniques are determined on the basis of their relationship to field exposure. Selected techniques were used to obtain neutron, photon, and beta energy spectra data at several Hanford locations. Four neutron energy spectra and dose measurement methods were used: (1) multisphere spectrometer system; (2) tissue equivalent proportional counter (TEPC); (3) RASCAL (9'' to 3'' sphere ratios); and (4) helium-3 neutron spectrometer. Gamma spectroscopy was done using standard techniques. A specially designed TLD dosimeter was used to obtain beta spectrum measurements. The design and use of each of these instruments is described in the body of this report. Data collected and analyzed for each of the Hanford locations are included

  6. Leaching Test Relationships, Laboratory-to-Field Comparisons and Recommendations for Leaching Evaluation using the Leaching Environmental Assessment Framework (LEAF)

    Science.gov (United States)

    This report presents examples of the relationships between the results of laboratory leaching tests, as defined by the Leaching Environmental Assessment Framework (LEAF) or analogous international test methods, and leaching of constituents from a broad range of materials under di...

  7. Fiscal 1997 research report on the data collection, evaluation and analysis in the PV power generation field test project for public facilities; 1997 nendo kokyo shisetsu nado yo taiyoko hatsuden field test jigyo ni okeru shushu data hyoka kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    As a part of the field test project for diffusing PV power generation into public facilities generally, evaluation and analysis were made on the collected data from 105 sites installed during fiscal 1993-1996. Analysis of operation characteristics was made by using parameters obtained by developing a basic equation for every component. 94% of all the sites fell under the total solar irradiation of 3.0- 4.5kWh/m{sup 2}/D. 83% of those fell under the equivalent array operation time of 2.5-4.0h/D. 70% of those fell under the equivalent system operation time of 2.5-3.5h/D. 72% of those fell under the system operation time of 9.0-12.0h/D. 78% of those fell under the effective inverter efficiency of 0.84- 0.96. 68% of those fell under the inverter load factor of 0.25-0.35. 85% of those fell under the array performance ratio of 0.7-1.0. 83% of those fell under the system performance ratio of 0.6-0.9. The generation cost decreased from 270yen/kWh in 1993 to 100yen/kWh in 1996 because reduction of an installation cost largely contributed to reduction of the total cost. (NEDO)

  8. Performance Evaluation of "Low-cost" Sensors for Measuring Gaseous and Particle Air Pollutants: Results from Two Years of Field and Laboratory Testing

    Science.gov (United States)

    Feenstra, B. J.; Polidori, A.; Tisopulos, L.; Papapostolou, V.; Zhang, H.; Pathmanabhan, J.

    2016-12-01

    In recent years great progress has been made in development of low-cost miniature air quality sensing technologies. Such low-cost sensors offer a prospect of providing a real-time spatially dense information on pollutants, however, the quality of the data produced by these sensors is so far untested. In an effort to inform the general public about the actual performance of commercially available low-cost air quality sensors, in June 2014 the South Coast Air Quality Management District (SCAQMD) has established the Air Quality Sensor Performance Evaluation Center (AQ-SPEC). This program performs a thorough characterization of low-cost sensors under ambient (in the field) and controlled (in the laboratory) conditions. During the field testing, air quality sensors are operated side-by-side with Federal Reference Methods and Federal Equivalent Methods (FRM and FEM, respectively), which are routinely used to measure the ambient concentration of gaseous or particle pollutants for regulatory purposes. Field testing is conducted at two of SCAQMD's existing air monitoring stations, one in Rubidoux and one near the I-710 freeway. Sensors that demonstrate an acceptable performance in the field are brought back to the lab where a "characterization chamber" is used to challenge these devices with known concentrations of different particle and gaseous pollutants under different temperature and relative humidity levels. Testing results for each sensor are then summarized in a technical report and, along with other relevant information, posted online on a dedicated website (www.aqmd.gov/aq-spec) to educate the public about the capabilities of commercially available sensors and their potential applications. During this presentation, the results from two years of field and laboratory testing will be presented. The major strengths and weaknesses of some of the most commonly available particle and gaseous sensors will be discussed.

  9. Field and Evaluation Methods Used to Test the Performance of a Stormceptor® Class 1 Stormwater Treatment Device in Australia

    Directory of Open Access Journals (Sweden)

    Peter Nichols

    2015-12-01

    Full Text Available Field testing of a proprietary stormwater treatment device was undertaken over 14 months at a site located in Nambour, South East Queensland. Testing was undertaken to evaluate the pollution removal performance of a Stormceptor® treatment train for removing total suspended solids (TSS, total nitrogen (TN and total phosphorous (TP from stormwater runoff. Water quality sampling was undertaken using natural rainfall events complying with an a priori sampling protocol. More than 59 rain events were monitored, of which 18 were found to comply with the accepted sampling protocol. The efficiency ratios (ER observed for the treatment device were found to be 83% for TSS, 11% for TP and 23% for TN. Although adequately removing TSS, additional system components, such as engineered filters, would be required to satisfy minimum local pollution removal regulations. The results of dry weather sampling tests did not conclusively demonstrate that pollutants were exported between storm events or that pollution concentrations increased significantly over time.

  10. Evaluation plan : national advanced rural transportation systems : field operational tests of traveler information services in tourism areas : executive summary

    Science.gov (United States)

    1998-07-01

    This evaluation addresses technical challenges of developing advanced traveler information systems (ATIS) in rural environments, institutional benefits and issues, usefulness of the information to the traveling public, effectiveness of various media ...

  11. Performance Evaluation of Advanced Retrofit Roof Technologies Using Field-Test Data Phase Three Final Report, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, Kaushik [ORNL; Childs, Phillip W [ORNL; Atchley, Jerald Allen [ORNL

    2014-05-01

    This article presents various metal roof configurations that were tested at Oak Ridge National Laboratory in Tennessee, U.S.A. between 2009 and 2013, and describes their potential for reducing the attic-generated space conditioning loads. These roofs contained different combinations of phase change material, rigid insulation, low emittance surface and above-sheathing ventilation, with standing-seam metal panels on top. These roofs were designed to be installed on existing roofs decks, or on top of asphalt shingles for retrofit construction. All the tested roofs showed the potential for substantial energy savings compared to an asphalt shingle roof, which was used as a control for comparison. The roofs were constructed on a series of adjacent attics separated at the gables using thick foam insulation. The attics were built on top of a conditioned room. All attics were vented at the soffit and ridge. The test roofs and attics were instrumented with an array of thermocouples. Heat flux transducers were installed in the roof deck and attic floor (ceiling) to measure the heat flows through the roof and between the attic and conditioned space below. Temperature and heat flux data were collected during the heating, cooling and swing seasons over a 3 year period. Data from previous years of testing have been published. Here, data from the latest roof configurations being tested in year 3 of the project are presented. All test roofs were highly effective in reducing the heat flows through the roof and ceiling, and in reducing the diurnal attic temperature fluctuations.

  12. Field testing plan for unsaturated zone monitoring and field studies

    International Nuclear Information System (INIS)

    Young, M.H.; Wierenga, P.J.; Warrick, A.W.

    1996-10-01

    The University of Arizona, in cooperation with the Bureau of Economic Geology at The University of Texas at Austin, and Stephens and Associates in Albuquerque, New Mexico has developed a field testing plan for evaluating subsurface monitoring systems. The U.S. Nuclear Regulatory Commission has requested development of these testing plans for low-level radioactive waste disposal sites (LLW) and for monitoring at decommissioned facilities designated under the open-quotes Site Decommissioning Management Planclose quotes (SDMP). The tests are conducted on a 50 m by 50 m plot on the University of Arizona's Maricopa Agricultural Center. Within the 50 m by 50 m plot one finds: (1) an instrumented buried trench, (2) monitoring islands similar to those proposed for the Ward Valley, California LLW Facility, (3) deep borehole monitoring sites, (4) gaseous transport monitoring, and (5) locations for testing non-invasive geophysical measurement techniques. The various subplot areas are instrumented with commercially available instruments such as neutron probes, time domain reflectometry probes, tensiometers, psychrometers, heat dissipation sensors, thermocouples, solution samplers, and cross-hole geophysics electrodes. Measurement depths vary from ground surface to 15 m. The data from the controlled flow and transport experiments, conducted over the plot, will be used to develop an integrated approach to long-term monitoring of the vadose zone at waste disposal sites. The data will also be used to test field-scale flow and transport models. This report describes in detail the design of the experiment and the methodology proposed for evaluating the data

  13. Behavior observation during conformation evaluation at a field test for Danish Warmblood horses and associations with rideability and performance traits

    DEFF Research Database (Denmark)

    Rothmann, Janne; Christensen, Ole F.; Søndergaard, Eva

    2014-01-01

    videotaped and scored for reactivity during the evaluation of their conformation, and a questionnaire was completed by the owners. Associations between reactivity and performance traits were investigated by computing partial correlations (Pearson, rp). A low negative correlation was found between rideability...... association was found between reactivity and ratings from owners (rp = 0.15, P = .02), indicating that horses considered to be nervous by their owners also were scored as reactive. In conclusion, it appears possible to measure reactivity in a practical situation. This study also concluded low negative...

  14. Evaluation of two counterflow traps for testing behaviour-mediating compounds for the malaria vector Anopheles gambiae s.s. under semi-field conditions in Tanzania

    NARCIS (Netherlands)

    Schmied, W.H.; Takken, W.; Killeen, G.F.; Knols, B.G.J.; Smallegange, R.C.

    2008-01-01

    Background Evaluation of mosquito responses towards different trap-bait combinations in field trials is a time-consuming process that can be shortened by experiments in contained semi-field systems. Possible use of the BG Sentinel (BGS) trap to sample Anopheles gambiae s.s. was evaluated. The

  15. Prototype Engineered Barrier System Field Test (PEBSFT)

    International Nuclear Information System (INIS)

    Ramirez, A.L.; Buscheck, T.; Carlson, R.; Daily, W.; Lee, K.; Lin, Wunan; Mao, Nai-hsien; Ueng, Tzou-Shin; Wang, H.; Watwood, D.

    1991-08-01

    This final report represents a summary of data and interpretations obtained from the Prototype Engineered Barrier System Field Test (PEBSFT) performed in G-Tunnel within the Nevada Test Site. The PEBSFT was conducted to evaluate the applicability of measurement techniques, numerical models, and procedures developed for future field tests that will be conducted in the Exploratory Studies Facilities (ESF) at Yucca Mountain. The primary objective of the test was to provide a basis for determining whether tests planned for the ESF have the potential to be successful. Chapter 1 on high frequency electromagnetic tomography discusses the rock mass electromagnetic permittivity and attenuation rate changes that were measured to characterize the water distribution in the near field of a simulated waste container. The data are used to obtain quantitative estimates of how the moisture content in the rock mass changes during heating and to infer properties of the spatial variability of water distribution, leading to conclusions about the role of fractures in the system. Chapter 2 discusses the changes in rock moisture content detected by the neutron logging probe. Chapter 3 permeability tests discusses the characterization of the in-situ permeability of the fractured tuff around the borehole. The air permeability testing apparatus, the testing procedures, and the data analysis are presented. Chapter 4 describes the moisture collection system installed in the heater borehole to trap and measure the moisture volumes. Chapter 5 describes relative humidity measurements made with the thermocouple psychrometer and capacitance sensors. Chapter 6 discusses gas pressure measurements in the G-Tunnel, addressing the calibration and installation of piezoresistive-gaged transducers. Chapter 7 describes the calibration and installation of thermocouples for temperature measurements. Chapter 8 discusses the results of the PEBSFT

  16. Field Test Evaluation of Conservation Retrofits of Low-Income, Single-Family Buildings in Wisconsin: Blower-Door-Directed Infiltration Reduction Procedure, Field Test Implementation and Results; TOPICAL

    International Nuclear Information System (INIS)

    Gettings, M.B.

    2001-01-01

    A blower-door-directed infiltration retrofit procedure was field tested on 18 homes in south central Wisconsin. The procedure, developed by the Wisconsin Energy Conservation Corporation, includes recommended retrofit techniques as well as criteria for estimating the amount of cost-effective work to be performed on a house. A recommended expenditure level and target air leakage reduction, in air changes per hour at 50 Pascal (ACH50), are determined from the initial leakage rate measured. The procedure produced an average 16% reduction in air leakage rate. For the 7 houses recommended for retrofit, 89% of the targeted reductions were accomplished with 76% of the recommended expenditures. The average cost of retrofits per house was reduced by a factor of four compared with previous programs. The average payback period for recommended retrofits was 4.4 years, based on predicted energy savings computed from achieved air leakage reductions. Although exceptions occurred, the procedure's 8 ACH50 minimum initial leakage rate for advising retrofits to be performed appeared a good choice, based on cost-effective air leakage reduction. Houses with initial rates of 7 ACH50 or below consistently required substantially higher costs to achieve significant air leakage reductions. No statistically significant average annual energy savings was detected as a result of the infiltration retrofits. Average measured savings were -27 therm per year, indicating an increase in energy use, with a 90% confidence interval of 36 therm. Measured savings for individual houses varied widely in both positive and negative directions, indicating that factors not considered affected the results. Large individual confidence intervals indicate a need to increase the accuracy of such measurements as well as understand the factors which may cause such disparity. Recommendations for the procedure include more extensive training of retrofit crews, checks for minimum air exchange rates to insure air quality

  17. Deep Borehole Field Test Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Ernest L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-09-30

    This report documents conceptual design development for the Deep Borehole Field Test (DBFT), including test packages (simulated waste packages, not containing waste) and a system for demonstrating emplacement and retrieval of those packages in the planned Field Test Borehole (FTB). For the DBFT to have demonstration value, it must be based on conceptualization of a deep borehole disposal (DBD) system. This document therefore identifies key options for a DBD system, describes an updated reference DBD concept, and derives a recommended concept for the DBFT demonstration. The objective of the DBFT is to confirm the safety and feasibility of the DBD concept for long-term isolation of radioactive waste. The conceptual design described in this report will demonstrate equipment and operations for safe waste handling and downhole emplacement of test packages, while contributing to an evaluation of the overall safety and practicality of the DBD concept. The DBFT also includes drilling and downhole characterization investigations that are described elsewhere (see Section 1). Importantly, no radioactive waste will be used in the DBFT, nor will the DBFT site be used for disposal of any type of waste. The foremost performance objective for conduct of the DBFT is to demonstrate safe operations in all aspects of the test.

  18. Comparative evaluation of chest radiography, low-field MRI, the Shwachman-Kulczycki score and pulmonary function tests in patients with cystic fibrosis

    International Nuclear Information System (INIS)

    Anjorin, Angela; Vogl, Thomas J.; Schmidt, Helga; Posselt, Hans-Georg; Smaczny, Christina; Ackermann, Hanns; Deimling, Michael; Abolmaali, Nasreddin

    2008-01-01

    The aim of this study was to investigate whether the parenchymal lung damage in patients suffering from cystic fibrosis (CF) can be equivalently quantified by the Chrispin-Norman (CN) scores determined with low-field magnetic resonance imaging (MRI) and conventional chest radiography (CXR). Both scores were correlated with pulmonary function tests (PFT) and the Shwachman-Kulczycki method (SKM). To evaluate the comparability of MRI and CXR for different states of the disease, all scores were applied to patients divided into three age groups. Seventy-three CF patients (mean SKM score: 62 ± 8) with a median age (range) of 14 years (7-32) were included. The mean CN scores determined with both imaging methods were comparable (CXR: 12.1 ± 4.7; MRI: 12.0 ± 4.5) and showed high correlation (P < 0.05, R = 0.97). Only weak correlations were found between imaging, PFT, and SKM. Both imaging modalities revealed significantly more severe disease expression with age, while PFT and SKM failed to detect early signs of disease. We conclude that imaging of the lung in CF patients is capable of detecting subtle and early parenchymal destruction before lung function or clinical scoring is affected. Furthermore, low-field MRI revealed high consistency with chest radiography and may be used for a thorough follow-up while avoiding radiation exposure. (orig.)

  19. In Situ Field Testing of Processes

    International Nuclear Information System (INIS)

    Wang, J.

    2001-01-01

    The purpose of this Analysis/Model Report (AMR) is to update and document the data and subsequent analyses from ambient field-testing activities performed in underground drifts of the Yucca Mountain Site Characterization Project (YMP). This revision updates data and analyses presented in the initial issue of this AMR. This AMR was developed in accordance with the ''Technical Work Plan for Unsaturated Zone (UZ) Flow and Transport Process Model Report'' and ''Technical Work Plan for UZ Flow, Transport, and Coupled Processes Process Model Report. These activities were performed to investigate in situ flow and transport processes. The evaluations provide the necessary framework to: (1) refine and confirm the conceptual model of matrix and fracture processes in the unsaturated zone (UZ) and (2) analyze the impact of excavation (including use of construction water and effect of ventilation) on the UZ flow and transport processes. This AMR is intended to support revisions to ''Conceptual and Numerical Models for UZ Flow and Transport'' and ''Unsaturated Zone Flow and Transport Model Process Model Report''. In general, the results discussed in this AMR are from studies conducted using a combination or a subset of the following three approaches: (1) air-injection tests, (2) liquid-release tests, and (3) moisture monitoring using in-drift sensors or in-borehole sensors, to evaluate the impact of excavation, ventilation, and construction-water usage on the surrounding rocks. The liquid-release tests and air-injection tests provide an evaluation of in situ fracture flow and the competing processes of matrix imbibition. Only the findings from testing and data not covered in the ''Seepage Calibration Model and Seepage Testing Data'' are analyzed in detail in the AMR

  20. In Situ Field Testing of Processes

    Energy Technology Data Exchange (ETDEWEB)

    J. Wang

    2001-12-14

    The purpose of this Analysis/Model Report (AMR) is to update and document the data and subsequent analyses from ambient field-testing activities performed in underground drifts of the Yucca Mountain Site Characterization Project (YMP). This revision updates data and analyses presented in the initial issue of this AMR. This AMR was developed in accordance with the ''Technical Work Plan for Unsaturated Zone (UZ) Flow and Transport Process Model Report'' and ''Technical Work Plan for UZ Flow, Transport, and Coupled Processes Process Model Report. These activities were performed to investigate in situ flow and transport processes. The evaluations provide the necessary framework to: (1) refine and confirm the conceptual model of matrix and fracture processes in the unsaturated zone (UZ) and (2) analyze the impact of excavation (including use of construction water and effect of ventilation) on the UZ flow and transport processes. This AMR is intended to support revisions to ''Conceptual and Numerical Models for UZ Flow and Transport'' and ''Unsaturated Zone Flow and Transport Model Process Model Report''. In general, the results discussed in this AMR are from studies conducted using a combination or a subset of the following three approaches: (1) air-injection tests, (2) liquid-release tests, and (3) moisture monitoring using in-drift sensors or in-borehole sensors, to evaluate the impact of excavation, ventilation, and construction-water usage on the surrounding rocks. The liquid-release tests and air-injection tests provide an evaluation of in situ fracture flow and the competing processes of matrix imbibition. Only the findings from testing and data not covered in the ''Seepage Calibration Model and Seepage Testing Data'' are analyzed in detail in the AMR.

  1. Field testing of bioenergetic models

    International Nuclear Information System (INIS)

    Nagy, K.A.

    1985-01-01

    Doubly labeled water provides a direct measure of the rate of carbon dioxide production by free-living animals. With appropriate conversion factors, based on chemical composition of the diet and assimilation efficiency, field metabolic rate (FMR), in units of energy expenditure, and field feeding rate can be estimated. Validation studies indicate that doubly labeled water measurements of energy metabolism are accurate to within 7% in reptiles, birds, and mammals. This paper discusses the use of doubly labeled water to generate empirical models for FMR and food requirements for a variety of animals

  2. Prototype Engineered Barrier System Field Tests (PEBSFT)

    International Nuclear Information System (INIS)

    Ramirez, A.L.; Wilder, D.G.

    1991-02-01

    This progress report presents the interpretation of data obtained (up to November 1, 1988) from the Prototype Engineered Barrier System Field Tests (PEBSFT) that are being performed for the Yucca Mountain Project (YMP) in G-Tunnel within the Nevada Test site. The PEBSFTs are being conducted to evaluate the applicability of measurement techniques, numerical models, and procedures developed for the field tests for future investigations that will be conducted in the Exploratory Shaft Facilities, at a potential high-level radioactive waste repository site in Yucca Mountain. The primary objective of the tests is to provide the basis for determining whether tests planned for Yucca Mountain have the potential to be successful. Thirteen chapters discuss the following: mapping the electromagnetic permittivity and attenuation rate of the rock mass; changes in moisture content detected by the neutron logging probe; characterization of the in-situ permeability of the fractured tuff around the heater borehole; electrical resistance heater installed in a 30-cm borehole; relative humidity measurements; the operation, design, construction, calibration, and installation of a microwave circuit that might provide partial pressure information at temperatures in excess of 200 degree C (392 degree F); pressure and temperature measurements in the G-Tunnel; the moisture collection system, which attempts to collect steam that migrates into the heater borehole; The borehole television and borescope surveys that were performed to map the location, orientation, and aperture of the fractures intersecting the boreholes; preliminary scoping calculations of the hydrothermal conditions expected for this prototype test; the Data Acquisition System; and the results of the PEBSFT, preliminary interpretations of these results, and plans for the remainder of the test. Chapters have been indexed separately for inclusion on the data base

  3. Fracture evaluation tests

    International Nuclear Information System (INIS)

    Robinson, G.C.

    1991-01-01

    In this report period, efforts have concentrated on defining the requirements for shallow-flaw beam testing. Analyses have been made to envelope the significant parameters for both deep- and shallow-flaw beams for three-point loading; that is, load to initiation of a frangible flaw, load to plastic collapse, LLD, and CMOD. An assessment was made of facilities capable of performing the tests identified by the parametric analyses discussed above. Two testing machines were identified for performing the scoped test series, the first a 550-kip Instron machine assigned to the Pressure Vessel Technology Section located in Building 9204-1 at the Y-12 Plant and the second a 220-kip MTS machine assigned to a mechanical testing group located at the K-25 Site. An existing bend test fixture previously used in the HSST clad plate test series is being modified for use in testing beams under other sponsorship but will be available for shared usage with the HSST shallow-flaw beam testing activities. To prevent the shared usage from having an adverse impact on the logistics of the HSST Program, the decision was made to procure a bend test fixture tailored specifically to serve the shallow flaw beam test series. A specification was prepared and procurement initiated. A survey is in progress for determining sources and costs of displacement-measuring instrumentation from both foreign and domestic sources. It appears that existing direct current displacement transducers available to the HSST Program may be adequate for the LLD measurements. These devices will be employed in the shakedown tests that are planned. A safety and environmental survey assessment for the beam testing conforming to the revised DOE rules has been prepared and approved

  4. Fiscal 1996 survey report. Data collection and evaluation analysis in the project on field tests on the fuel cell generation; 1996 nendo kenkyu hokokusho. Nenryo denchi hatsuden field test jigyo ni okeru data shuyaku oyobi hyoka kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The paper installed fuel cell power generation equipment experimentally at various facilities which are the final diffusion form of the new energy power generation, conducted long-term operation under the actual load, collected/analyzed various data, arranged them as data useful for full scale introduction/diffusion, aiming at forming the base for general diffusion of the fuel cell power generation. The number of the systems installed for field test execution has been 24 places/28 units since the start of the project, and the system capacity totaled 4,250kW. The actual operation hours in five years are 6,000-28,000. In fiscal 1996, the average cumulative accumulated operational rate was approximately 68%, a little over that in fiscal 1995, 65%. The average load factor was 69% in fiscal 1995 and 70% in fiscal 1996. The utilization rate increased as a whole to about 57% on average if seeing only fiscal 1996, as compared with that in fiscal 1995, about 48%. The power generating efficiency was approximately 34% on average. As to the status of shutdown of the fuel cell power generation, the paper surveyed the average interval of failure, the rate of frequency of shutdown, the analysis of shutdown, etc. 250 figs., 29 tabs.

  5. FY1992 research report on the evaluation and analysis of data collected in fuel cell power generation field test project; 1992 nendo nenryo denchi hatsuden field test jigyo ni okeru shushu data hyoka kaiseki kenkyu hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-03-01

    This paper describes the achievements in fiscal 1992 in the field tests on fuel cell power generation systems. The three locations subjected to the present analysis are all installed with 50-kW systems, whereas power generation efficiency of around 35% such as 35.3, 34.2 and 34.6% was obtained when the systems were operated at the rated output. When the load gets to below a certain load band (about 30 kW), the power generation efficiency decreases proportionately with the load. The overall efficiency including heat supply was 77.8, 70.7 and 80.3% respectively at about the rated output, showing a trend that the higher the thermal efficiency, the higher the overall efficiency. The case of generating both electric power and heat simultaneously has higher efficiency than the case of heat supply alone. The contribution rate of the fuel cell as a base load was 2.8, 4.6 and 13.6%, respectively. The system with as high value as 13.6% takes a power load following type operation mode, in which power is generated during a time band with large load during weekdays, and no power is generated at nighttime and in holidays when load is smaller, playing a role of peak responding power supply. Only one trouble has occurred in an auxiliary generator in the heat recovery system. (NEDO)

  6. FY 1998 evaluation/analysis of the data collected in the field test project for photovoltaic power generation for public facilities; 1998 nendo kokyo shisetsu nadoyo taiyoko hatsuden field test jigyo ni okeru shushu data hyoka kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    In the field test project for the photovoltaic power generation for public facilities, operational data were collected/analyzed on facilities at 158 sites installed from FY 1994 to FY 1997. As a result, the following were found out: Average values of the global radiation on an inclined surface, equivalent array operation time, equivalent system operation time, system operation time, inverter performance efficiency, inverter load factor, array power coefficient, and system power coefficient are 3.51 kWh/m{sup 2}/D, 2.72 h/D, 2.47 h/D, 10.3 h/D, 0.91, 0.30, 0.77 and 0.70, respectively. No deterioration with age was recognized in the 4-year operation data. As to the maintenance, the item, 'there are a lot of failures in the photovoltaic power system,' was 2% in rate. As to the inspection, times are mostly once a month. The annual maintenance cost was widely between about 360 yen/kW and about 30,000 yen/kW. Supposing annual expenses to be a total of capital expense, direct expense, and general administrative expense, the power generation cost dropped from approximately 240 yen/kWh in FY 1994 to 100 yen/kWh in FY 1997. (NEDO)

  7. Deep Borehole Field Test Laboratory and Borehole Testing Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlman, Kristopher L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brady, Patrick V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); MacKinnon, Robert J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Heath, Jason E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Herrick, Courtney G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jensen, Richard P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gardner, W. Payton [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sevougian, S. David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bryan, Charles R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jang, Je-Hun [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stein, Emily R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bauer, Stephen J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Daley, Tom [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Freifeld, Barry M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Birkholzer, Jens [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Spane, Frank A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-19

    Deep Borehole Disposal (DBD) of high-level radioactive wastes has been considered an option for geological isolation for many years (Hess et al. 1957). Recent advances in drilling technology have decreased costs and increased reliability for large-diameter (i.e., ≥50 cm [19.7”]) boreholes to depths of several kilometers (Beswick 2008; Beswick et al. 2014). These advances have therefore also increased the feasibility of the DBD concept (Brady et al. 2009; Cornwall 2015), and the current field test design will demonstrate the DBD concept and these advances. The US Department of Energy (DOE) Strategy for the Management and Disposal of Used Nuclear Fuel and High-Level Radioactive Waste (DOE 2013) specifically recommended developing a research and development plan for DBD. DOE sought input or expression of interest from States, local communities, individuals, private groups, academia, or any other stakeholders willing to host a Deep Borehole Field Test (DBFT). The DBFT includes drilling two boreholes nominally 200m [656’] apart to approximately 5 km [16,400’] total depth, in a region where crystalline basement is expected to begin at less than 2 km depth [6,560’]. The characterization borehole (CB) is the smaller-diameter borehole (i.e., 21.6 cm [8.5”] diameter at total depth), and will be drilled first. The geologic, hydrogeologic, geochemical, geomechanical and thermal testing will take place in the CB. The field test borehole (FTB) is the larger-diameter borehole (i.e., 43.2 cm [17”] diameter at total depth). Surface handling and borehole emplacement of test package will be demonstrated using the FTB to evaluate engineering feasibility and safety of disposal operations (SNL 2016).

  8. In situ respiration testing: A field treatability test for bioventing

    International Nuclear Information System (INIS)

    Kittel, J.A.; Hinchee, R.E.; Miller, R.; Vogel, C.; Hoeppel, R.

    1993-01-01

    Bioventing is the process of aerating subsurface soils to stimulate in situ biological activity and promote bioremediation. Bioventing differs from soil venting in remedial approach. Soil venting is designed and operated to maximize the volatilization of low-molecular-weight compounds, with some biodegradation occurring. In contrast, bioventing is designed to maximize biodegradation of aerobically biodegradable compounds, regardless of their molecular weight, with some volatilization occurring. Bioventing is gaining wide acceptance as a remediation alternative at petroleum-contaminated sites. However, site variability usually requires that a short term treatability test be conducted in situ at potential sites to determine the applicability of bioventing. Battelle has worked with the US Air Force and the US Navy to develop a simple and inexpensive field test to evaluate bioventing potential-contaminated sites. This test has been used to evaluate the applicability of bioventing at over 50 sites. The in situ respiration test consists of injecting air and an inert tracer gas (helium) over a 24-hour period to aerate soils at an oxygen-deficient, petroleum-contaminated site. Soil vapor samples are collected to determine oxygen utilization rates and carbon dioxide production rates. The stoichiometric relationship for the oxidation of hexane is used to calculate the biodegradation rate. The tracer gas is monitored to estimate the effect of diffusion on changes in soil-gas concentrations

  9. Field testing of sulphide electrodes

    International Nuclear Information System (INIS)

    Singh, P.R.; Gaonkar, K.B.; Gadiyar, H.S.

    1993-01-01

    Sulphide ion selective electrodes have been developed at BARC, for determination of Ag + and S - ions directly and Cl - and CN - ions indirectly. The electrodes were tested for their use in sulphide environments in the EAD (Effluent After Dilution) stream at the Heavy Water Plant, Kota. The electrodes are suitable in the concentration range of 16000 ppm to 0.002 ppm, with a slope of 29-31 mV per decade change in the sulphide ion concentration. The response time is less than 10 seconds. These electrodes are reliable for continuous on-line use for a long period. (author). 7 refs., 11 figs., 1 tab

  10. Development and field test of psychophysical tests for DWI arrest

    Science.gov (United States)

    1981-03-01

    Administration and scoring procedures were standardized for a sobriety test battery consisting of the walk-and-turn test, the one leg stand test, and horizontal gaze nystagmus. The effectiveness of the standardized battery was then evaluated in the l...

  11. Test fields cannot destroy extremal black holes

    International Nuclear Information System (INIS)

    Natário, José; Queimada, Leonel; Vicente, Rodrigo

    2016-01-01

    We prove that (possibly charged) test fields satisfying the null energy condition at the event horizon cannot overspin/overcharge extremal Kerr–Newman or Kerr–Newman–anti de Sitter black holes, that is, the weak cosmic censorship conjecture cannot be violated in the test field approximation. The argument relies on black hole thermodynamics (without assuming cosmic censorship), and does not depend on the precise nature of the fields. We also discuss generalizations of this result to other extremal black holes. (paper)

  12. 3X-100 blade field test.

    Energy Technology Data Exchange (ETDEWEB)

    Zayas, Jose R.; Johnson, Wesley D.

    2008-03-01

    In support of a Work-For-Other (WFO) agreement between the Wind Energy Technology Department at Sandia National Laboratories and 3TEX, one of the three Micon 65/13M wind turbines at the USDA Agriculture Research Service (ARS) center in Bushland, Texas, has been used to test a set of 9 meter wind turbine blades, manufactured by TPI composites using the 3TEX carbon material for the spar cap. Data collected from the test has been analyzed to evaluate both the aerodynamic performance and the structural response from the blades. The blades aerodynamic and structural performance, the meteorological inflow and the wind turbine structural response has been monitored with an array of 57 instruments: 15 to characterize the blades, 13 to characterize inflow, and 15 to characterize the time-varying state of the turbine. For the test, data was sampled at a rate of 40 Hz using the ATLAS II (Accurate GPS Time-Linked Data Acquisition System) data acquisition system. The system features a time-synchronized continuous data stream and telemetered data from the turbine rotor. This paper documents the instruments and infrastructure that have been developed to monitor these blades, turbines and inflow, as well as both modeling and field testing results.

  13. IN SITU FIELD TESTING OF PROCESSES

    Energy Technology Data Exchange (ETDEWEB)

    J.S.Y. YANG

    2004-11-08

    The purpose of this scientific analysis report is to update and document the data and subsequent analyses from ambient field-testing activities performed in underground drifts and surface-based boreholes through unsaturated zone (UZ) tuff rock units. In situ testing, monitoring, and associated laboratory studies are conducted to directly assess and evaluate the waste emplacement environment and the natural barriers to radionuclide transport at Yucca Mountain. This scientific analysis report supports and provides data to UZ flow and transport model reports, which in turn contribute to the Total System Performance Assessment (TSPA) of Yucca Mountain, an important document for the license application (LA). The objectives of ambient field-testing activities are described in Section 1.1. This report is the third revision (REV 03), which supercedes REV 02. The scientific analysis of data for inputs to model calibration and validation as documented in REV 02 were developed in accordance with the Technical Work Plan (TWP) ''Technical Work Plan for: Performance Assessment Unsaturated Zone'' (BSC 2004 [DIRS 167969]). This revision was developed in accordance with the ''Technical Work Plan for: Unsaturated Zone Flow Analysis and Model Report Integration'' (BSC 2004 [DIRS 169654], Section 1.2.4) for better integrated, consistent, transparent, traceable, and more complete documentation in this scientific analysis report and associated UZ flow and transport model reports. No additional testing or analyses were performed as part of this revision. The list of relevant acceptance criteria is provided by ''Technical Work Plan for: Unsaturated Zone Flow Analysis and Model Report Integration'' (BSC 2004 [DIRS 169654]), Table 3-1. Additional deviations from the TWP regarding the features, events, and processes (FEPs) list are discussed in Section 1.3. Documentation in this report includes descriptions of how, and under what

  14. IN SITU FIELD TESTING OF PROCESSES

    International Nuclear Information System (INIS)

    YANG, J.S.Y.

    2004-01-01

    The purpose of this scientific analysis report is to update and document the data and subsequent analyses from ambient field-testing activities performed in underground drifts and surface-based boreholes through unsaturated zone (UZ) tuff rock units. In situ testing, monitoring, and associated laboratory studies are conducted to directly assess and evaluate the waste emplacement environment and the natural barriers to radionuclide transport at Yucca Mountain. This scientific analysis report supports and provides data to UZ flow and transport model reports, which in turn contribute to the Total System Performance Assessment (TSPA) of Yucca Mountain, an important document for the license application (LA). The objectives of ambient field-testing activities are described in Section 1.1. This report is the third revision (REV 03), which supercedes2. The scientific analysis of data for inputs to model calibration and validation as documented in2 were developed in accordance with the Technical Work Plan (TWP) ''Technical Work Plan for: Performance Assessment Unsaturated Zone'' (BSC 2004 [DIRS 167969]). This revision was developed in accordance with the ''Technical Work Plan for: Unsaturated Zone Flow Analysis and Model Report Integration'' (BSC 2004 [DIRS 169654], Section 1.2.4) for better integrated, consistent, transparent, traceable, and more complete documentation in this scientific analysis report and associated UZ flow and transport model reports. No additional testing or analyses were performed as part of this revision. The list of relevant acceptance criteria is provided by ''Technical Work Plan for: Unsaturated Zone Flow Analysis and Model Report Integration'' (BSC 2004 [DIRS 169654]), Table 3-1. Additional deviations from the TWP regarding the features, events, and processes (FEPs) list are discussed in Section 1.3. Documentation in this report includes descriptions of how, and under what conditions, the tests were conducted. The descriptions and analyses

  15. Hydrogen Field Test Standard: Laboratory and Field Performance

    Science.gov (United States)

    Pope, Jodie G.; Wright, John D.

    2015-01-01

    The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give equivalent answers if proper sensors without drift are

  16. Handheld Standoff Mine Detection System (HSTAMIDS) Field Evaluation in Thailand

    National Research Council Canada - National Science Library

    Doheny, Robert C; Burke, Sean; Cresci, Roger; Ngan, Peter; Walls, Richard

    2005-01-01

    ...) and with participation from the International Test and Evaluation Project (ITEP) for Humanitarian Demining, conducted an in-country field evaluation of HSTAMIDS in the region of Humanitarian Demining Unit #1 (HMAU1) in Thailand...

  17. Buildings, fields of activity, testing facilities

    International Nuclear Information System (INIS)

    1974-01-01

    Since 1969 the activities of the Materialpruefungsanstalt Stuttgart (MPA) have grown quickly as planned, especially in the field of reactor safety research, which made it necessary to increase the staff to approximately 165 members, to supplement the machines and equipment and to extend the fields of activities occasioning a further departmental reorganization. At present the MPA has the following departments: 1. Teaching (materials testing, materials science and strength of materials) 2. Materials and Welding Technology 3. Materials Science and General Materials Testing with Tribology 4. Design and Strength 5. Creep and Fatigue Testing 6. Central Facilities 7. Vessel and Component Testing. (orig./RW) [de

  18. The Savannah River environmental technology field test platform

    International Nuclear Information System (INIS)

    Rossabi, J.; Riha, B.D.

    1995-01-01

    The principal goal in the development of new technologies for environmental monitoring and characterization is transferring them to organizations and individuals for use in site assessment and compliance monitoring. The Savannah River technology Center (SRTC) has been developing a program to rigorously field test promising environmental technologies that have not undergone EPA equivalency testing. The infrastructure and staff expertise developed as part of the activities of the Savannah River Integrated Demonstration Program allows field testing of technologies without the difficulties of providing remote field support. By providing a well-characterized site and a well-developed infrastructure, technologies are tested in actual field scenarios to determine their appropriate applications in environmental characterization and monitoring activities. The field tests provide regulatory organizations, potential industrial partners, and potential users with the opportunity to evaluate the technology's performance and its utility for implementation in environmental characterization and monitoring programs. This program has resulted in the successful implementation of several new technologies

  19. Advanced Vehicle Testing and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Garetson, Thomas [The Clarity Group, Incorporated, Chicago, IL (United States)

    2013-03-31

    The objective of the United States (U.S.) Department of Energy's (DOEs) Advanced Vehicle Testing and Evaluation (AVTE) project was to provide test and evaluation services for advanced technology vehicles, to establish a performance baseline, to determine vehicle reliability, and to evaluate vehicle operating costs in fleet operations.Vehicles tested include light and medium-duty vehicles in conventional, hybrid, and all-electric configurations using conventional and alternative fuels, including hydrogen in internal combustion engines. Vehicles were tested on closed tracks and chassis dynamometers, as well as operated on public roads, in fleet operations, and over prescribed routes. All testing was controlled by procedures developed specifically to support such testing.

  20. IMOM Field Test Study and Accuracy Verification

    National Research Council Canada - National Science Library

    Levien, Fred

    1998-01-01

    .... It was desired to obtain flight test data for both TAMPS and IMOM in order to compare their ability to accurately predict the effects of Radar Terrain Masking (RTM). It was initially planned to have NPS compare predictive data from both of these systems and then do analysis of how they compared to actual field test data.

  1. The Center-TRACON Automation System: Simulation and field testing

    Science.gov (United States)

    Denery, Dallas G.; Erzberger, Heinz

    1995-01-01

    A new concept for air traffic management in the terminal area, implemented as the Center-TRACON Automation System, has been under development at NASA Ames in a cooperative program with the FAA since 1991. The development has been strongly influenced by concurrent simulation and field site evaluations. The role of simulation and field activities in the development process will be discussed. Results of recent simulation and field tests will be presented.

  2. Evaluation of the Radiochemistry of Near-Field Water Samples at the Nevada Test Site Applied to the Definition of a Hydrologic Source Term

    International Nuclear Information System (INIS)

    Smith, D K

    2002-01-01

    Effective management of available groundwater resources and strategies for remediation of water impacted by past nuclear testing practices depend on knowledge about the migration of radionuclides in groundwater away from the sites of the explosions. A primary concern is to assess the relative mobilities of the different radionuclide species found near sites of underground nuclear tests and to determine the concentration, extent, and speed of this movement. Ultimately the long term transport behavior of radionuclides with half-lives long enough that they will persist for decades, their interaction with groundwater, and the resulting flux of these contaminants is of paramount importance. As part of a comprehensive approach to these assessments, more than three decades of site-specific sites studies have been undertaken at the Nevada Test Site (NTS) which have focused on the means responsible for the observed or suspected movement of radionuclides away from underground nuclear tests (RNM, 1983). More recently regional and local models of groundwater flow and radionuclide transport have been developed as part of a federal and state of Nevada program to assess the long-term effects of underground nuclear testing on human health and environment (e.g., U.S. DOE/NV, 1997a; Tompson et al., 1999; Pawloski et al., 2001). Necessary to these efforts is a reliable measure of the hydrologic source term which is defined as those radionuclides dissolved in or otherwise transported by groundwater (Smith et al., 1995). Measurement of radionuclides in waters sampled near the sites of underground nuclear test provides arguably the best opportunity to bound the hydrologic source term. This empirical approach was recognized early and concentration data has been collected annually since mid-1970's. Initially three sites were studied at the NTS; over the years the program has been expanded to include more than fifteen study locations. As part of various field programs, Lawrence Livermore

  3. Testing of the structural evaluation test unit

    International Nuclear Information System (INIS)

    Ammerman, D.J.; Bobbe, J.G.

    1995-01-01

    In the evaluation of the safety of radioactive material transportation it is important to consider the response of Type B packages to environments more severe than that prescribed by the hypothetical accident sequence in Title 10 Part 71 of the Code of Federal Regulations (NRC 1995). The impact event in this sequence is a 9-meter drop onto an essentially unyielding target, resulting in an impact velocity of 13.4 m/s. The behavior of 9 packages when subjected to impacts more severe than this is not well known. It is the purpose of this program to evaluate the structural response of a test package to these environments. Several types of structural response are considered. Of primary importance is the behavior of the package containment boundary, including the bolted closure and 0-rings. Other areas of concern are loss of shielding capability due to lead slump and the deceleration loading of package contents, that may cause damage to them. This type of information is essential for conducting accurate risk assessments on the transportation of radioactive materials. Currently very conservative estimates of the loss of package protection are used in these assessments. This paper will summarize the results of a regulatory impact test and three extra-regulatory impact tests on a sample package

  4. Background field coils for the High Field Test Facility

    International Nuclear Information System (INIS)

    Zbasnik, J.P.; Cornish, D.N.; Scanlan, R.M.; Jewell, A.M.; Leber, R.L.; Rosdahl, A.R.; Chaplin, M.R.

    1980-01-01

    The High Field Test Facility (HFTF), presently under construction at LLNL, is a set of superconducting coils that will be used to test 1-m-o.d. coils of prototype conductors for fusion magnets in fields up to 12 T. The facility consists of two concentric sets of coils; the outer set is a stack of Nb-Ti solenoids, and the inner set is a pair of solenoids made of cryogenically-stabilized, multifilamentary Nb 3 Sn superconductor, developed for use in mirror-fusion magnets. The HFTF system is designed to be parted along the midplane to allow high-field conductors, under development for Tokamak fusion machines, to be inserted and tested. The background field coils were wound pancake-fashion, with cold-welded joints at both the inner and outer diameters. Turn-to-turn insulation was fabricated at LLNL from epoxy-fiberglass strip. The coils were assembled and tested in our 2-m-diam cryostat to verify their operation

  5. Combustion Safety Simplified Test Protocol Field Study

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L. [Gas Technology Inst., Des Plaines, IL (United States); Cautley, D. [Gas Technology Inst., Des Plaines, IL (United States); Bohac, D. [Gas Technology Inst., Des Plaines, IL (United States); Francisco, P. [Gas Technology Inst., Des Plaines, IL (United States); Shen, L. [Gas Technology Inst., Des Plaines, IL (United States); Gloss, S. [Gas Technology Inst., Des Plaines, IL (United States)

    2015-11-01

    Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project team collected field data on 11 houses in 2015.

  6. Sultan - forced flow, high field test facility

    International Nuclear Information System (INIS)

    Horvath, I.; Vecsey, G.; Weymuth, P.; Zellweger, J.

    1981-01-01

    Three European laboratories: CNEN (Frascati, I) ECN (Petten, NL) and SIN (Villigen, CH) decided to coordinate their development efforts and to install a common high field forced flow test facility at Villigen Switzerland. The test facility SULTAN (Supraleiter Testanlage) is presently under construction. As a first step, an 8T/1m bore solenoid with cryogenic periphery will be ready in 1981. The cryogenic system, data acquisition system and power supplies which are contributed by SIN are described. Experimental feasibilities, including cooling, and instrumentation are reviewed. Progress of components and facility construction is described. Planned extension of the background field up to 12T by insert coils is outlined. 5 refs

  7. Numerical simulations of capillary barrier field tests

    International Nuclear Information System (INIS)

    Morris, C.E.; Stormont, J.C.

    1997-01-01

    Numerical simulations of two capillary barrier systems tested in the field were conducted to determine if an unsaturated flow model could accurately represent the observed results. The field data was collected from two 7-m long, 1.2-m thick capillary barriers built on a 10% grade that were being tested to investigate their ability to laterally divert water downslope. One system had a homogeneous fine layer, while the fine soil of the second barrier was layered to increase its ability to laterally divert infiltrating moisture. The barriers were subjected first to constant infiltration while minimizing evaporative losses and then were exposed to ambient conditions. The continuous infiltration period of the field tests for the two barrier systems was modelled to determine the ability of an existing code to accurately represent capillary barrier behavior embodied in these two designs. Differences between the field test and the model data were found, but in general the simulations appeared to adequately reproduce the response of the test systems. Accounting for moisture retention hysteresis in the layered system will potentially lead to more accurate modelling results and is likely to be important when developing reasonable predictions of capillary barrier behavior

  8. Some Tests on Heather Field Moraine Clay

    DEFF Research Database (Denmark)

    Jørgensen, Mogens B.; Jacobsen, Moust

    This report deals with oedometer tests on three samples of moraine clay from the Heather Field in the English part of the North Sea. The tests have been carried out in the very unelastic apparatus used in Denmark and with special test procedures differing from the ones used elsewhere. In Denmark...... Moraine Clay covers a large part of the surface, and it has therefore been investigated extensively in the field and in the laboratories during the last 25 years. It is to day - from a geotechnical point of view - the best known clay in Denmark. It could therefore be of some interest to compare...... the English North Sea moraine clays with the corresponding Danish Moraine Clays. The Danish test procedures are explained in details and some comments are given in the hope that they may not be banalities all of them....

  9. Automated particulate sampler field test model operations guide

    Energy Technology Data Exchange (ETDEWEB)

    Bowyer, S.M.; Miley, H.S.

    1996-10-01

    The Automated Particulate Sampler Field Test Model Operations Guide is a collection of documents which provides a complete picture of the Automated Particulate Sampler (APS) and the Field Test in which it was evaluated. The Pacific Northwest National Laboratory (PNNL) Automated Particulate Sampler was developed for the purpose of radionuclide particulate monitoring for use under the Comprehensive Test Ban Treaty (CTBT). Its design was directed by anticipated requirements of small size, low power consumption, low noise level, fully automatic operation, and most predominantly the sensitivity requirements of the Conference on Disarmament Working Paper 224 (CDWP224). This guide is intended to serve as both a reference document for the APS and to provide detailed instructions on how to operate the sampler. This document provides a complete description of the APS Field Test Model and all the activity related to its evaluation and progression.

  10. Field evaluation of prototype electrofibrous filters

    International Nuclear Information System (INIS)

    Kuhl, W.D.; Bergman, W.; Biermann, A.H.; Lum, B.Y.

    1982-01-01

    New prototype electrofibrous filters were designed, built and evaluated in laboratory tests and in field installations. Two prototypes were designed for use in nuclear ventilation ducts as prefilters to HEPA filters. One prototype is designed to be a permanent component of the ventilation system while the other is a disposable unit. The disposable electrofibrous prefilter was installed in the exhaust stream of a glove box in which barrels of uranium turnings are burned. Preliminary tests show the disposal prefilter is effectively prolonging the HEPA filter life. An earlier prototype of the rolling prefilter was upgraded to meet the increased requirements for installation in a nuclear facility. This upgraded prototype was evaluated in the fire test facility at LLNL and shown to be effective in protecting HEPA filters from plugging under the most severe smoke conditions. The last prototype described in this report is a recirculating air filter. After demonstrating a high performance in laboratory tests the unit was shipped to Savannah River where it is awaiting installation in a Pu fuel fabrication facility. An analysis of the particulate problem in Savannah River indicates that four recirculating air filter will save $172,000 per year in maintenance costs

  11. Comparative Field Tests of Pressurised Rover Prototypes

    Science.gov (United States)

    Mann, G. A.; Wood, N. B.; Clarke, J. D.; Piechochinski, S.; Bamsey, M.; Laing, J. H.

    The conceptual designs, interior layouts and operational performances of three pressurised rover prototypes - Aonia, ARES and Everest - were field tested during a recent simulation at the Mars Desert Research Station in Utah. A human factors experiment, in which the same crew of three executed the same simulated science mission in each of the three vehicles, yielded comparative data on the capacity of each vehicle to safely and comfortably carry explorers away from the main base, enter and exit the vehicle in spacesuits, perform science tasks in the field, and manage geological and biological samples. As well as offering recommendations for design improvements for specific vehicles, the results suggest that a conventional Sports Utility Vehicle (SUV) would not be suitable for analog field work; that a pressurised docking tunnel to the main habitat is essential; that better provisions for spacesuit storage are required; and that a crew consisting of one driver/navigator and two field science crew specialists may be optimal. From a field operations viewpoint, a recurring conflict between rover and habitat crews at the time of return to the habitat was observed. An analysis of these incidents leads to proposed refinements of operational protocols, specific crew training for rover returns and again points to the need for a pressurised docking tunnel. Sound field testing, circulating of results, and building the lessons learned into new vehicles is advocated as a way of producing ever higher fidelity rover analogues.

  12. Evaluation of resistance in a selected field strain of Haemonchus contortus to ivermectin and moxidectin using the Larval Migration on Agar Test

    Directory of Open Access Journals (Sweden)

    Fernanda S. Fortes

    2013-02-01

    Full Text Available Haemonchus contortus is one of the most common and economically significant causes of disease in small ruminants worldwide, and the control programs of parasitic nematodes - including H. contortus - rely mostly on the use of anthelmintic drugs. The consequence of the use of this, as the sole sanitary strategy to avoid parasite infections, was the reduction of the efficacy of all chemotherapeutic products with a heavy selection for resistance. The widespread of anthelmintic resistance and the difficulty of its early diagnosis has been a major concern for the sustainable parasite management on farms. The objective of this research was to determine and compare the ivermectin (IVM and moxidectin (MOX effect in a selected field strain of H. contortus with a known resistance status, using the in vitro larval migration on agar test (LMAT. Third stage larvae of the selected isolate were obtained from faecal cultures of experimentally infected sheep and incubated in eleven increasing diluted concentrations of IVM and MOX (6, 12, 24, 48, 96, 192, 384, 768, 1536, 3072 and 6144µg/mL. The dose-response sigmoidal curves were obtained using the R² value of >0.90 and the lethal concentration (LC50 dose for the tested anthelmintic drugs using a four-parameter logistic model. The LC50 value for MOX was significantly lower than IVM (1.253µg/mL and 91.06µg/mL, identifying the H. contortus isolate as considerably less susceptible to IVM compared to MOX. Furthermore, the LMAT showed a high consistency (p<0.0001 and provided to be a useful diagnostic tool for monitoring the resistance status of IVM and MOX in H. contortus field isolate, as well as it may be used for official routine drug monitoring programs under the Ministry of Agriculture (MAPA guidance.

  13. Field test of coordinated ramp metering (CRM).

    Science.gov (United States)

    2017-03-15

    This project has focused on field implementation and testing of a Coordinated Ramp Metering (CRM) algorithm at California State Route 99 : Northbound corridor in Sacramento between Calvine Road and the SR50 interchange after 12th Ave. It is a 9 mile ...

  14. Magnetic Field Strength Evaluation Yu. S. Yefimov

    Indian Academy of Sciences (India)

    physical task is to evaluate the strength and topology of magnetic field in blazars and related ... polarization, spectral index of radiation, ratio of apparent velocity of the motion of matter along .... A detailed analysis of the evaluation of physical.

  15. Evaluation of New Fluid Mud Survey System at Field Sites

    National Research Council Canada - National Science Library

    Engler

    1992-01-01

    This technical note presents an intermediate evaluation of a fluid mud survey system with respect to operability, practicability, and repeatability based on field tests conducted at Calcasieu River, Louisiana...

  16. Maintenance proficiency evaluation test bank

    International Nuclear Information System (INIS)

    Maier, Loran

    2003-01-01

    The Maintenance Proficiency Evaluation Test Bank (MPETB) is an Electric Power Research Institute- (EPRJ-) operated, utility-sponsored means of developing, maintaining, and disseminating secure, high-quality written and performance maintenance proficiency tests. EPRTs charter is to ensure that all tests and test items that go into the Test Bank have been validated, screened for reliability, and evaluated to high standards of psychometric excellence. Proficiency tests of maintenance personnel.(mechanics, electricians, and instrumentation and control [I and C] technicians) are most often used to determine if an experienced employee is capable of performing maintenance tasks without further training. Such tests provide objective evidence for decisions to exempt an employee from what, for the employee, is unnecessary training. This leads to considerable savings in training costs and increased productivity because supervisors can assign personnel to tasks at which their competence is proven. The ultimate objective of proficiency evaluation is to ensure that qualified maintenance personnel are available to meet the maintenance requirements of the plant Numerous task-specific MPE tests (both written and performance) have been developed and validated using the EPRI MPE methodology by the utilities participating in the MPETB project A task-specific MPE consists of a multiple-choice written examination and a multi-step performance evaluation that can be used to assess an individual's present knowledge and skill level for a given maintenance task. The MPETB contains MPEs and test items for the mechanical, electrical, and I and C classifications that are readily available to participating utilities. Presently, utilities are placing emphasis on developing MPEs to evaluate outage-related maintenance tasks that demonstrate the competency and qualifications of plant and contractor personnel before the start of outage work. Utilities are also using the MPE methodology and process to

  17. Walkthrough screening evaluation field guide

    International Nuclear Information System (INIS)

    Eder, S.J.; Eli, M.W.; Salmon, M.W.

    1993-11-01

    The US Department of Energy (DOE) has a large inventory of existing facilities. Many of these facilities were not designed and constructed to current natural phenomena hazard (NPH) criteria. The NPH events include earthquakes, extreme winds and tornadoes, and floods. DOE Order 5480.28 establishes policy and requirements for NPH mitigation for DOE facilities. DOE is conducting a multiyear project to develop evaluation guidelines for assessing the condition and determining the need for upgrades at DOE facilities. One element of the NPH evaluation guidelines' development involves the existing systems and components at DOE facilities. This effort is described in detail in a cited reference. In the interim period prior to availability of the final guidelines, DOE facilities are encouraged to implement an NPH walk through screening evaluation process by which systems and components that need attention can be rapidly identified. Guidelines for conducting the walk through screening evaluations are contained herein. The result of the NPH walk through screening evaluation should be a prioritized list of systems and components that need further action. Simple and inexpensive fixes for items identified in the walk through as marginal or inadequate should be implemented without further study. By implementing an NPH walk through screening evaluation, DOE facilities may realize significant reduction in risk from NPH in the short term

  18. Field Testing of Cryogenic Carbon Capture

    Energy Technology Data Exchange (ETDEWEB)

    Sayre, Aaron [Sustainable Energy Solutions, LLC; Frankman, Dave [Sustainable Energy Solutions, LLC; Baxter, Andrew [Sustainable Energy Solutions, LLC; Stitt, Kyler [Sustainable Energy Solutions, LLC; Baxter, Larry [Sustainable Energy Solutions, LLC; Brigham Young Univ., Provo, UT (United States)

    2017-07-17

    Sustainable Energy Solutions has been developing Cryogenic Carbon Capture™ (CCC) since 2008. In that time two processes have been developed, the External Cooling Loop and Compressed Flue Gas Cryogenic Carbon Capture processes (CCC ECL™ and CCC CFG™ respectively). The CCC ECL™ process has been scaled up to a 1TPD CO2 system. In this process the flue gas is cooled by an external refrigerant loop. SES has tested CCC ECL™ on real flue gas slip streams from subbituminous coal, bituminous coal, biomass, natural gas, shredded tires, and municipal waste fuels at field sites that include utility power stations, heating plants, cement kilns, and pilot-scale research reactors. The CO2 concentrations from these tests ranged from 5 to 22% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2 and PMxx at 95+%. NO was also captured at a modest rate. The CCC CFG™ process has been scaled up to a .25 ton per day system. This system has been tested on real flue gas streams including subbituminous coal, bituminous coal and natural gas at field sites that include utility power stations, heating plants, and pilot-scale research reactors. CO2 concentrations for these tests ranged from 5 to 15% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2 and PMxx at 95+%. NO was also captured at 90+%. Hg capture was also verified and the resulting effluent from CCC CFG™ was below a 1ppt concentration. This paper will focus on discussion of the capabilities of CCC, the results of field testing and the future steps surrounding the development of this technology.

  19. The accuracy of prediction of genomic selection in elite hybrid rye populations surpasses the accuracy of marker-assisted selection and is equally augmented by multiple field evaluation locations and test years.

    Science.gov (United States)

    Wang, Yu; Mette, Michael Florian; Miedaner, Thomas; Gottwald, Marlen; Wilde, Peer; Reif, Jochen C; Zhao, Yusheng

    2014-07-04

    Marker-assisted selection (MAS) and genomic selection (GS) based on genome-wide marker data provide powerful tools to predict the genotypic value of selection material in plant breeding. However, case-to-case optimization of these approaches is required to achieve maximum accuracy of prediction with reasonable input. Based on extended field evaluation data for grain yield, plant height, starch content and total pentosan content of elite hybrid rye derived from testcrosses involving two bi-parental populations that were genotyped with 1048 molecular markers, we compared the accuracy of prediction of MAS and GS in a cross-validation approach. MAS delivered generally lower and in addition potentially over-estimated accuracies of prediction than GS by ridge regression best linear unbiased prediction (RR-BLUP). The grade of relatedness of the plant material included in the estimation and test sets clearly affected the accuracy of prediction of GS. Within each of the two bi-parental populations, accuracies differed depending on the relatedness of the respective parental lines. Across populations, accuracy increased when both populations contributed to estimation and test set. In contrast, accuracy of prediction based on an estimation set from one population to a test set from the other population was low despite that the two bi-parental segregating populations under scrutiny shared one parental line. Limiting the number of locations or years in field testing reduced the accuracy of prediction of GS equally, supporting the view that to establish robust GS calibration models a sufficient number of test locations is of similar importance as extended testing for more than one year. In hybrid rye, genomic selection is superior to marker-assisted selection. However, it achieves high accuracies of prediction only for selection candidates closely related to the plant material evaluated in field trials, resulting in a rather pessimistic prognosis for distantly related material

  20. High Efficiency Water Heating Technology Development Final Report. Part I, Lab/Field Performance Evaluation and Accelerated Life Testing of a Hybrid Electric Heat Pump Water Heater (HPWH)

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Murphy, Richard W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linkous, Randall Lee [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-04-01

    DOE has supported efforts for many years with the objective of getting a water heater that uses heat pump technology (aka a heat pump water heater or HPWH) successfully on the residential equipment market. The most recent previous effort (1999-2002) produced a product that performed very well in ORNL-led accelerated durability and field tests. The commercial partner for this effort, Enviromaster International (EMI), introduced the product to the market under the trade name Watter$aver in 2002 but ceased production in 2005 due to low sales. A combination of high sales price and lack of any significant infrastructure for service after the sale were the principal reasons for the failure of this effort. What was needed for market success was a commercial partner with the manufacturing and market distribution capability necessary to allow economies of scale to lead to a viable unit price together with a strong customer service infrastructure. General Electric certainly meets these requirements, and knowing of ORNL s expertise in this area, approached ORNL with the proposal to partner in a CRADA to produce a high efficiency electric water heater. A CRADA with GE was initiated early in Fiscal Year, 2008. GE initially named its product the Hybrid Electric Water Heater (HEWH).

  1. Combustion Safety Simplified Test Protocol Field Study

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L [Gas Technology Inst., Des Plaines, IL (United States); Cautley, D. [Gas Technology Inst., Des Plaines, IL (United States); Bohac, D. [Gas Technology Inst., Des Plaines, IL (United States); Francisco, P. [Gas Technology Inst., Des Plaines, IL (United States); Shen, L. [Gas Technology Inst., Des Plaines, IL (United States); Gloss, S. [Gas Technology Inst., Des Plaines, IL (United States)

    2015-11-05

    "9Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.

  2. Integrated Test and Evaluation Flight Test 3 Flight Test Plan

    Science.gov (United States)

    Marston, Michael Lawrence

    2015-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration into the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability, Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including the integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project will conduct a series of Human-in-the-Loop and Flight Test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity and complexity of the previous tests and

  3. Nuclear explosives testing readiness evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Valk, T.C.

    1993-09-01

    This readiness evaluation considers hole selection and characterization, verification, containment issues, nuclear explosive safety studies, test authorities, event operations planning, canister-rack preparation, site preparation, diagnostic equipment setup, device assembly facilities and processes, device delivery and insertion, emplacement, stemming, control room activities, readiness briefing, arming and firing, test execution, emergency response and reentry, and post event analysis to include device diagnostics, nuclear chemistry, and containment. This survey concludes that the LLNL program and its supporting contractors could execute an event within six months of notification, and a second event within the following six months, given the NET group`s evaluation and the following three restraints: (1) FY94 (and subsequent year) funding is essentially constant with FY93, (2) Preliminary work for the initial event is completed to the historical sic months status, (3) Critical personnel, currently working in dual use technologies, would be recallable as needed.

  4. Field-based evaluations of horizontal flat-plate fish screens, II: Testing of a unique off-stream channel device - The Farmers Screen

    Science.gov (United States)

    Mesa, Matthew G.; Rose, Brien P.; Copeland, Elizabeth S.

    2012-01-01

    Screens are installed at water diversion sites to reduce entrainment of fish. Recently, the Farmers Irrigation District (Oregon) developed a unique flat-plate screen (the “Farmers Screen”) that operates passively and may offer reduced installation and operating costs. To evaluate the effectiveness of this screen on fish, we conducted two separate field experiments. First, juvenile coho salmon Oncorhynchus kisutch were released over a working version of this screen under a range of inflows (0.02–0.42 m3/s) and diversion flows (0.02–0.34 m3/s) at different water depths. Mean approach velocities ranged from 0 to 5 cm/s and sweeping velocities ranged from 36 to 178 cm/s. Water depths over the screen surface ranged from 1 to 25 cm and were directly related to inflow. Passage of fish over the screen under these conditions did not severely injure them or cause delayed mortality, and no fish were observed becoming impinged on the screen surface. Second, juvenile coho salmon and steelhead O. mykiss were released at the upstream end of a 34-m flume and allowed to volitionally move downstream and pass over a 3.5-m section of the Farmers Screen to determine whether fish would refuse to pass over the screen after encountering its leading edge. For coho salmon, 75–95% of the fish passed over the screen within 5 min and 82–98% passed within 20 min, depending on hydraulic conditions. For steelhead, 47–90% of the fish passed over the screen within 5 min and 79–95% passed within 20 min. Our results indicate that when operated within its design criteria, the Farmers Screen provides safe and efficient downstream passage of juvenile salmonids under a variety of hydraulic conditions.

  5. A prototype tap test imaging system: Initial field test results

    Science.gov (United States)

    Peters, J. J.; Barnard, D. J.; Hudelson, N. A.; Simpson, T. S.; Hsu, D. K.

    2000-05-01

    This paper describes a simple, field-worthy tap test imaging system that gives quantitative information about the size, shape, and severity of defects and damages. The system consists of an accelerometer, electronic circuits for conditioning the signal and measuring the impact duration, a laptop PC and data acquisition and processing software. The images are generated manually by tapping on a grid printed on a plastic sheet laid over the part's surface. A mechanized scanner is currently under development. The prototype has produced images for a variety of aircraft composite and metal honeycomb structures containing flaws, damages, and repairs. Images of the local contact stiffness, deduced from the impact duration using a spring model, revealed quantitatively the stiffness reduction due to flaws and damages, as well as the stiffness enhancement due to substructures. The system has been field tested on commercial and military aircraft as well as rotor blades and engine decks on helicopters. Field test results will be shown and the operation of the system will be demonstrated.—This material is based upon work supported by the Federal Aviation Administration under Contract #DTFA03-98-D-00008, Delivery Order No. IA016 and performed at Iowa State University's Center for NDE as part of the Center for Aviation Systems Reliability program.

  6. Field Evaluation of Programmable Thermostats

    Energy Technology Data Exchange (ETDEWEB)

    Sachs, O.; Tiefenbeck, V.; Duvier, C.; Qin, A.; Cheney, K.; Akers, C.; Roth, K.

    2012-12-01

    Prior research suggests that poor programmable thermostats usability may prevent their effective use to save energy. We hypothesized that home occupants with a high-usability thermostats would be more likely to use them to save energy than people with a basic thermostat. We randomly installed a high-usability thermostat in half the 77 apartments of an affordable housing complex, installing a basic thermostat in the other half. During the heating season, we collected space temperature and furnace on-off data to evaluate occupant interaction with the thermostats, foremost nighttime setbacks. We found that thermostat usability did not influence energy-saving behaviors, finding no significant difference in temperature maintained among apartments with high- and low-usability thermostats.

  7. FY 1999 Evaluation and analysis of the data collected by the field test project for photovoltaic power generation in public facilities. By site (1/3); 1999 nendo kokyo shisetsu nadoyo taiyoko hatsuden field test jigyo ni okeru shushu data hyoka kaiseki. 1/3. Kaku site betsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    Described herein are the results of evaluation and analysis of the data (management nos.701 to 814) collected by the field test project for photovoltaic power generation in a total of 45 facilities, mainly public. Each system is operated for 30 to 31 days every month. A total of 23 items of the data described below are recorded every day, and totaled up, averaged and evaluated for effectiveness at the end of the month: solar radiation on a horizontal, sloped and effective sloped plane, average air temperature, array electric energy, system electric energy, system power consumption, load electric energy, load for supplying power to a network, electric energy of reversed flow, linkage protection actions, linkage parallel off time, system operation time, self-sustaining load, load of voluntary supply, equivalent array operation, equivalent system operation, array output coefficient, system output coefficient, system utilization, system power generation efficiency, INV effective efficiency, and INV load factor. (NEDO)

  8. Field evaporation test of uranium tailings solution

    International Nuclear Information System (INIS)

    Chandler, B.L.; Shepard, T.A.; Stewart, T.A.

    1985-01-01

    A field experiment was performed to observe the effect on evaporation rate of a uranium tailings impoundment pond water as salt concentration of the water increased. The duration of the experiment was long enough to cause maximum salt concentration of the water to be attained. The solution used in the experiment was tailings pond water from an inactive uranium tailings disposal site in the initial stages of reclamation. The solution was not neutralized. The initial pH was about 1.0 decreasing to a salt gel at the end of the test. The results of the field experiment show a gradual and slight decrease in evaporation efficiency. This resulted as salt concentrations increased and verified the practical effectiveness of evaporation as a water removal method. In addition, the physical and chemical nature of the residual salts suggest that no long-term stability problem would likely result due to their presence in the impoundment during or after reclamation

  9. Performance Test of CCTV in a Test Field

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyung Min [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2011-10-15

    On April 12-13, 2010, US President Obama hosted a Nuclear Security Summit in Washington, DC, to enhance international cooperation to prevent nuclear terrorism, an issue which he has identified as the most immediate and extreme threat to global security. The Summit focused on the security of nuclear materials, nonproliferation, disarmament, and peaceful nuclear energy. At the summit, the Republic of Korea was chosen as the host of the next Summit in 2012. This series of events reflects the growing global interest on 'Nuclear Security' and as the host country of the next Nuclear Summit it is the time for Korea to strengthen the physical protection regime for nuclear facilities as a first step of securing its nuclear security capability. KINAC has been operating Test field as a mean of preparing solid backup data for reviewing and revising DBT (Design Basis Threat) and to test components of the conventional physical protection system. CCTV is a key component which is used worldwide for the assessment measure of alarms. In terms of performance test of CCTV, there are several elements such as image quality, coverage and mechanical features (speed of zoom-in-out, capture, angle shift etc.). Speaking of image quality acquired by the CCTV, the quality is subject to resolution, monitor specification, camera housing, camera mounting and lightening. Thus it is clear that performance tests on image quality should consider those factors and vary the factors respectively in order to verify the influence and the interaction among those. Nevertheless due to the restrictions of the current Test field, this paper focuses on the image quality through resolution test under the various lightening conditions

  10. Performance analysis in Japanese field test program; Field test data kara no chiiki hatsuden kaiseki hoho

    Energy Technology Data Exchange (ETDEWEB)

    Sugiyama, H.; Kurokawa, K.; Uchida, D. [Tokyo University of Agriculture and Technology, Tokyo (Japan); Otani, K.; Sakuta, K.; Tsuda, I. [Electrotechnical Laboratory, Tsukuba (Japan); Oshiro, T.; Sakamoto, K. [Japan Quality Assurance Organization, Tokyo (Japan)

    1997-11-25

    Power generation characteristics are investigated using data collected in photovoltaic power generation field tests being undertaken by NEDO (New Energy and Industrial Technology Development Organization). The photovoltaic power generation system performance is evaluated by examining loss factors leading to degradation in system performance, with weather conditions such as variation in insolation and air temperature, inverter performance, and shadows cast by surrounding buildings taken into consideration. As the result, it is found that the important loss factors are degradation in module performance due to elevated temperature, drift in the maximum output control, degraded inverter performance due to input power variation, effect of shadows, etc. It is learned that system is greatly affected by degradation in module performance due to increased temperature in summer and by shadows in winter, the two being responsible for the output coefficient dropping to approximately 75% throughout the year. The output coefficient frequency distribution charts for the 75 test sites confirm that the rate is as low as 70-80% at many sites. As for the system operating time, it tends to be longer in West Japan where the annual insolation rate is higher. 3 refs., 10 figs.

  11. Issues related to field testing in tuff

    International Nuclear Information System (INIS)

    Zimmerman, R.M.

    1982-01-01

    This paper has brought out the unique properties of tuffs and related them to needs associated with their use as a host rock for a high level nuclear waste repository. Major issues of temperature, pore water, joints, and depositional patterns have been identified and related responses and impacts outlined in Table 1. Planned experiments have been outlined and their relationships to the rock mechanics issues summarized in Table 2. The conclusions from this paper are: (1) tuff is a complex rock and basic phenomenological understanding is incomplete; and (2) available field test facilities will be used for a series of experiments designed to improve phenomenological understanding and support repository design efforts

  12. The Savannah River environmental technology field test platform: Phase II

    International Nuclear Information System (INIS)

    Rossabi, J.; Riha, B.D.; May, C.P.; Pemberton, B.E.; Jarosch, T.R.; Eddy-Dilek, C.A.; Looney, B.B.; Raymond, R.

    1995-01-01

    The principal goal in the development of new technologies for environmental monitoring and characterization is transferring them to organizations and individuals for use in site assessment and compliance monitoring. The DOE complex has devised several strategies to facilitate this transfer including joint research projects between private industries and government laboratories or universities (CRADAs), and streamlined licensing procedures. One strategy that has been under-utilized is a planned sequence gradually moving from laboratory development and field demonstration to long term evaluation and onsite use. Industrial partnership and commercial production can be initiated at any step based on the performance, market, user needs, and costs associated with the technology. The Savannah River Technology Center (SRTC) has been developing a program to rigorously field test promising environmental technologies that have not undergone EPA equivalency testing. The infrastructure and staff expertise developed as part of the activities of the Savannah River Integrated Demonstration Program (i.e., wells, available power, conventional baseline characterization and monitoring equipment, shelter structures) allows field testing of technologies without the difficulties of providing remote field support. By providing a well-characterized site and a well-developed infrastructure, technologies can be tested for long periods of time to determine their appropriate applications in environmental characterization and monitoring activities. Situation specific evaluations of the technology following stringent test plans can be made in comparison with simultaneous baseline methods and historical data. This program is designed to help expedite regulatory approval and technology transfer to manufacturers and the user community

  13. Evaluating the RELM Test Results

    Directory of Open Access Journals (Sweden)

    Michael K. Sachs

    2012-01-01

    Full Text Available We consider implications of the Regional Earthquake Likelihood Models (RELM test results with regard to earthquake forecasting. Prospective forecasts were solicited for M≥4.95 earthquakes in California during the period 2006–2010. During this period 31 earthquakes occurred in the test region with M≥4.95. We consider five forecasts that were submitted for the test. We compare the forecasts utilizing forecast verification methodology developed in the atmospheric sciences, specifically for tornadoes. We utilize a “skill score” based on the forecast scores λfi of occurrence of the test earthquakes. A perfect forecast would have λfi=1, and a random (no skill forecast would have λfi=2.86×10-3. The best forecasts (largest value of λfi for the 31 earthquakes had values of λfi=1.24×10-1 to λfi=5.49×10-3. The best mean forecast for all earthquakes was λ̅f=2.84×10-2. The best forecasts are about an order of magnitude better than random forecasts. We discuss the earthquakes, the forecasts, and alternative methods of evaluation of the performance of RELM forecasts. We also discuss the relative merits of alarm-based versus probability-based forecasts.

  14. Fiber optic sensor applications in field testing

    International Nuclear Information System (INIS)

    Perea, J.A.

    1984-01-01

    Fiber optic sensors (F.O.S.) are defined, and the application of this technology to measuring various phenomonon in diverse and hostile environments are discussed. F.O.S. advantages and disavantages both technically and operationally are summarized. Three sensor techniques - intensity, interferometric, and polarization - are then discussed in some detail. General environmental instrumentation and controls that support the Nuclear Weapons Test Program at the Nevada Test Site are discussed next to provide the reader with a basic understanding of the programmatic task. This will aid in recognizing the various difficulties of the traditional measurement techniques at the NTS and the potential advantages that fiber optic measurement systems can provide. An F.O.S. development program is then outlined, depicting a plan to design and fabricate a prototype sensor to be available for field testing by the end of FY84. We conclude with future plans for further development of F.O.S. to measure more of the desired physical parameters for the Test Program, and to eventually become an integral part of an overall measurement and control system

  15. Field Tests of a Portable MEMS Gravimeter

    Directory of Open Access Journals (Sweden)

    Richard P. Middlemiss

    2017-11-01

    Full Text Available Gravimeters are used to measure density anomalies under the ground. They are applied in many different fields from volcanology to oil and gas exploration, but present commercial systems are costly and massive. A new type of gravity sensor has been developed that utilises the same fabrication methods as those used to make mobile phone accelerometers. In this study, we describe the first results of a field-portable microelectromechanical system (MEMS gravimeter. The stability of the gravimeter is demonstrated through undertaking a multi-day measurement with a standard deviation of 5.58 × 10 − 6 ms − 2 . It is then demonstrated that a change in gravitational acceleration of 4.5 × 10 − 5 ms − 2 can be measured as the device is moved between the top and the bottom of a 20.7 m lift shaft with a signal-to-noise ratio (SNR of 14.25. Finally, the device is demonstrated to be stable in a more harsh environment: a 4.5 × 10 − 4 ms − 2 gravity variation is measured between the top and bottom of a 275-m hill with an SNR of 15.88. These initial field-tests are an important step towards a chip-sized gravity sensor.

  16. Solid oxide fuel cell field trial evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Wilcox, C.P.; Winstanley, R.; Nietsch, T.; Smith, C.; Knight, R.; Seymore, C.

    2000-07-01

    This report focuses on issues relating to a field trial of a solid oxide fuel cell (SOFC). Aspects examined include markets for SOFC systems, the choice of systems for demonstration in year 2002, the assessment of industrial interest, and evaluation and ranking of candidate systems. The identification and evaluation of interest in field trials, the estimation of the capital and running costs of a field trial, and identification of the benefits to the UK and barriers to implementation of SOFC systems are discussed. (UK)

  17. Computer-aided dispatch--traffic management center field operational test final detailed test plan : WSDOT deployment

    Science.gov (United States)

    2003-10-01

    The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : WSDOT deployment". This document defines the objective, approach,...

  18. Computer-aided dispatch--traffic management center field operational test final test plans : state of Utah

    Science.gov (United States)

    2004-01-01

    The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : state of Utah". This document defines the objective, approach, an...

  19. FY 2000 report on the survey of the project on field tests on the introduction of high performance industrial furnaces. Analysis/evaluation of the collected data; 2000 nendo koseino kogyoro donyu field test jigyo chosa hokokusho. Shushu data kaiseki hyoka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    For the purpose of achieving the target of reduction in CO2 regarded as substance causing global warming which was agreed at COP3, the study has been made since FY 1993 on 'the development of high performance industrial furnaces (regenerative combustion furnace using heat storage type burner for realization of high temperature air combustion).' By applying the good results obtained, a field test project for introduction of high performance industrial furnace has been implemented for three years (FY 1998 - FY 2000) to confirm the actual performance, reliability, etc. Collection/arrangement were made mainly of the data obtained in this field test project for the introduction of high performance industrial furnaces in each fiscal year (1998, 1999 and 2000), and verification/evaluation and arrangement were made. In this R and D, energy conservation was achieved at a rate of more than 30% of the target. Also about NOx, the result was obtained that the NOx by energy saving can be reduced 50% in almost all kinds of furnace if adding the reduction amount in emission amount and the reduction amount by high temperature air combustion. About the quality, the good result was obtained. Downsizing was conducted in approximately 10 examples. (NEDO)

  20. FY 2000 report on the survey of the project on field tests on the introduction of high performance industrial furnaces. Analysis/evaluation of the collected data; 2000 nendo koseino kogyoro donyu field test jigyo chosa hokokusho. Shushu data kaiseki hyoka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    For the purpose of achieving the target of reduction in CO2 regarded as substance causing global warming which was agreed at COP3, the study has been made since FY 1993 on 'the development of high performance industrial furnaces (regenerative combustion furnace using heat storage type burner for realization of high temperature air combustion).' By applying the good results obtained, a field test project for introduction of high performance industrial furnace has been implemented for three years (FY 1998 - FY 2000) to confirm the actual performance, reliability, etc. Collection/arrangement were made mainly of the data obtained in this field test project for the introduction of high performance industrial furnaces in each fiscal year (1998, 1999 and 2000), and verification/evaluation and arrangement were made. In this R and D, energy conservation was achieved at a rate of more than 30% of the target. Also about NOx, the result was obtained that the NOx by energy saving can be reduced 50% in almost all kinds of furnace if adding the reduction amount in emission amount and the reduction amount by high temperature air combustion. About the quality, the good result was obtained. Downsizing was conducted in approximately 10 examples. (NEDO)

  1. FIELD TEST OF THE FLAME QUALITY INDICATOR

    Energy Technology Data Exchange (ETDEWEB)

    Rudin, Andrew M; Butcher, Thomas; Troost, Henry

    2003-02-04

    The flame quality indicator concept was developed at BNL specifically to monitor the brightness of the flame in a small oil burner and to provide a ''call for service'' notification when the brightness has changed from its setpoint, either high or low. In prior development work BNL has explored the response of this system to operational upsets such as excess air changes, fouled atomizer nozzles, poor fuel quality, etc. Insight Technologies, Inc. and Honeywell, Inc. have licensed this technology from the U.S. Department of Energy and have been cooperating to develop product offerings which meet industry needs with an optimal combination of function and price. Honeywell has recently completed the development of the Flame Quality Monitor (FQM or Honeywell QS7100F). This is a small module which connects via a serial cable to the burners primary operating control. Primary advantages of this approach are simplicity, cost, and ease of installation. Call-for-service conditions are output in the form of front panel indicator lights and contact closure which can trigger a range of external communication options. Under this project a field test was conducted of the FQM in cooperation with service organizations in Virginia, Pennsylvania, New Jersey, New York, and Connecticut. At total of 83 field sites were included. At each site the FQM was installed in parallel with another embodiment of this concept--the Insight AFQI. The AFQI incorporates a modem and provides the ability to provide detailed information on the trends in the flame quality over the course of the two year test period. The test site population was comprised of 79.5% boilers, 13.7% warm air furnaces, and 6.8% water heaters. Nearly all were of residential size--with firing rates ranging from 0.6 gallons of oil per hour to 1.25. During the course of the test program the monitoring equipment successfully identified problems including: plugged fuel lines, fouled nozzles, collapsed combustion

  2. Cooperative field test program for wind systems

    Energy Technology Data Exchange (ETDEWEB)

    Bollmeier, W.S. II; Dodge, D.M.

    1992-03-01

    The objectives of the Federal Wind Energy Program, managed by the US Department of Energy (DOE), are (1) to assist industry and utilities in achieving a multi-regional US market penetration of wind systems, and (2) to establish the United States as the world leader in the development of advanced wind turbine technology. In 1984, the program conducted a series of planning workshops with representatives from the wind energy industry to obtain input on the Five-Year Research Plan then being prepared by DOE. One specific suggestion that came out of these meetings was that the federal program should conduct cooperative research tests with industry to enhance the technology transfer process. It was also felt that the active involvement of industry in DOE-funded research would improve the state of the art of wind turbine technology. DOE established the Cooperative Field Test Program (CFTP) in response to that suggestion. This program was one of the first in DOE to feature joint industry-government research test teams working toward common objectives.

  3. Field test plan: Buried waste technologies, Fiscal Year 1995

    International Nuclear Information System (INIS)

    Heard, R.E.; Hyde, R.A.; Engleman, V.S.; Evans, J.D.; Jackson, T.W.

    1995-06-01

    The US Department of Energy, Office of Technology Development, supports the applied research, development, demonstration, testing, and evaluation of a suite of advanced technologies that, when integrated with commercially available baseline technologies, form a comprehensive remediation system for the effective and efficient remediation of buried waste. The Fiscal Year 1995 effort is to deploy and test multiple technologies from four functional areas of buried waste remediation: site characterization, waste characterization, retrieval, and treatment. This document is the basic operational planning document for the deployment and testing of the technologies that support the field testing in Fiscal Year 1995. Discussed in this document are the scope of the tests; purpose and objective of the tests; organization and responsibilities; contingency plans; sequence of activities; sampling and data collection; document control; analytical methods; data reduction, validation, and verification; quality assurance; equipment and instruments; facilities and utilities; health and safety; residuals management; and regulatory management

  4. Applied field test procedures on petroleum release sites

    International Nuclear Information System (INIS)

    Gilbert, G.; Nichols, L.

    1995-01-01

    The effective remediation of petroleum contaminated soils and ground water is a significant issue for Williams Pipe Line Co. (Williams): costing $6.8 million in 1994. It is in the best interest, then, for Williams to adopt approaches and apply technologies that will be both cost-effective and comply with regulations. Williams has found the use of soil vapor extraction (SVE) and air sparging (AS) field test procedures at the onset of a petroleum release investigation/remediation accomplish these goals. This paper focuses on the application of AS/SVE as the preferred technology to a specific type of remediation: refined petroleum products. In situ field tests are used prior to designing a full-scale remedial system to first validate or disprove initial assumptions on applicability of the technology. During the field test, remedial system design parameters are also collected to tailor the design and operation of a full-scale system to site specific conditions: minimizing cost and optimizing effectiveness. In situ field tests should be designed and operated to simulate as close as possible the operation of a full-scale remedial system. The procedures of an in situ field test will be presented. The results of numerous field tests and the associated costs will also be evaluated and compared to full-scale remedial systems and total project costs to demonstrate overall effectiveness. There are many advantages of As/SVE technologies over conventional fluid extraction or SVE systems alone. However, the primary advantage is the ability to simultaneously reduce volatile and biodegradable compound concentrations in the phreatic, capillary fringe, and unsaturated zones

  5. Boraflex test results and evaluation

    International Nuclear Information System (INIS)

    Lindquist, K.; Kline, D.E.; Haley, T.C.

    1993-02-01

    New data developed, collected, and evaluated to further assess the in-pool performance of the neutron absorber material, Boraflex. The data are from new EPRI test programs, utility surveillance programs, and blackness testing at a number of plants. This new data provides a basis for quantifying the gap phenomenon in full length panels of Boraflex in spent fuel racks; the maximum anticipated gap size, frequency of gap occurrence, and axial distribution of gaps. Methods have been developed to assess the reactivity effects of gaps and Boraflex shrinkage. The analyses presented demonstrates that the reactivity effect of gaps is very small, not much larger than the statistical variations inherent in the calculational method. The data and analyses presented serve to close the issue of gap formation and shrinkage in panels of Boraflex and the effect of such gaps and shrinkage on the reactivity of the fuel/rack configuration. Ongoing EPRI programs to assess the long term performance of Boraflex in spent fuel storage racks are described

  6. Protection of testes during radiation treatment by irregular and focused fields of 25 MV x-rays: in vivo evaluation of the absorbed dose.

    Science.gov (United States)

    Marcie, S; Costa, A; Lagrange, J L

    1995-01-01

    During therapeutic irradiation of subdiaphragmatic nodal areas, the gonads are exposed to radiation from the primary beam and scatter. Since young patients have a high probability of cure, limiting exposure to the gonads should be pursued. Primary shielding may be supplemented by additional shields in order to reduce this exposure. Testes dose measurements were performed with thermoluminescent dosimetry (TLD) in 37 patients treated with 25 MV x-rays on subdiaphragmatic nodal areas. Each patient was measured 5 times while under treatment. In 27 cases, an additional shield was placed to protect the testes. For 9 cases, comparative measurements were performed on a phantom with and without additional shielding. The median dose received by gonads was respectively 3% with additional shielding (27 cases) and 5.8% without additional shielding (10 cases, p = 0.001 Mann Whitney test). In the 6 patients for whom the measurements were compared, the differences were also statistically significant (p = 0.028 paired Wilcoxon test). This study confirmed the benefit of additional gonadal shielding during subdiaphragmatic radiation treatment with 25 MV x-rays.

  7. FY 2001 study report on the evaluation/analysis of the data collected in the field test project on the photovoltaic power generation for public facilities, etc.; 2001 nendo kenkyu seika hokokusho. Kokyo shisetsu you taiyoko hatsuden field test jigyo ni okeru shushu data hyoka kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-03-01

    As a field test project on the photovoltaic power generation, collection/analysis/evaluation of the operational data were made about photovoltaic power systems installed at 73 places in FY 2001. As to the analysis of deterioration with age and yearly changes of the system, analysis was made of operation hours of the equivalent system, system output coefficient and inverter performance efficiency in FY 1999, FY 2000 and FY 2001, and it was confirmed that there was few deterioration with age. Relating to the evaluation of reliability of the system, evaluation was made for the record of failures of photovoltaic power systems at 73 places, and the results were not very good as follows: average failure cycle: 1.06 y/system; average failure repair period: 14.9 d/system; rough opportunity loss electric energy: 81,548 kWh/y x 73 sites. Concerning the analysis of economical efficiency, the system cost decreased year by year to 1,102,000 yen/kW in FY 1997, and the power generation cost became 91.8 yen/kWh. The fund recovery year was 35.3 years, assuming the following: unit price of selling electricity: 15 yen/kWh, durable years: 20 years, and public subsidiary rate: 1/2. (NEDO)

  8. Field tests for the comparative evaluation of heat and enthalpy exchangers in compact ventilation units; Feldvergleich von Waerme- und Enthalpieuebertragern in Kompakt-Lueftungsgeraeten - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Frei, B.

    2007-07-01

    In an efficiency review on low energy buildings promoted by the Swiss Federal Office of Energy, low air humidity has been measured during thousands of annual hours. Modern compact ventilation units are being increasingly offered with transmission of heat and moisture. One possibility to raise the air humidity level is an enthalpy exchanger with steam-permeable membranes. With an enthalpy exchanger you can not only recover heat but also a good part of the humidity of the return air. In a comparative field study alternate applications with enthalpy or heat exchangers have been analysed at four different locations. Also calculations have been made to estimate how a rotating heat exchanger with ion-exchange resin would have performed. The comparative field study has shown that the enthalpy exchanger is able to raise the humidity level. Conditions for this are internal humidity loads, balanced air volume rates which correspond to occupancy as well as low leakages of the ventilation unit. Over-moistening due to the system with enthalpy exchanger was not found. The measurements have been affected by a sequence of winter months which have been partially warmer than usual. Otherwise the difference between enthalpy and heat exchangers would have been more significant. (author)

  9. Field operational tests of Smartway in Japan

    Directory of Open Access Journals (Sweden)

    Fumihiko Kanazawa

    2010-07-01

    Full Text Available Efforts are underway in Japan to promote “Smartway” next-generation roadways, which provide a variety of services through the use of advanced ITS technologies. In recent years, the National Institute for Land and Infrastructure Management (NILIM, part of the Ministry of Land, Infrastructure, Transport and Tourism (MLIT, has conducted public–private joint research on next-generation road services using ITS technologies. Field operational tests (FOTs of services including forward obstacle information provision and merging assistance using 5.8 GHz dedicated short range communication (DSRC were conducted on the Tokyo Metropolitan Expressway through FY2007. In FY2008–2009, FOTs were conducted in three major metropolitan areas—Tokyo, Nagoya, and Keihanshin (Kyoto, Osaka, and Kobe—to promote future deployment nationwide. These included tests of information provision services to alert drivers to forward obstacles hidden beyond the crest of an incline and prevent excessive speed on sharp curves. This paper presents an overview of these FOTs conducted by NILIM in recent years and their results.

  10. Field testing at the Climax Stock on the Nevada Test Site: spent fuel test and radionuclide migration experiments

    International Nuclear Information System (INIS)

    Ballou, L.B.; Isherwood, D.J.; Patrick, W.C.

    1982-01-01

    Two field tests in the Climax Stock are being conducted. The Climax Stock, a granitic instrusive, has been administratively excluded from consideration as a full-scale repository site. However, it provides a readily available facility for field testing with high-level radioactive materials at a depth (420 m) approaching that of a repository. The major test activity in the 1980 fiscal year has been initiation of the Spent Fuel Test-Climax (SFT-C). This test, which was authorized in June 1978, is designed to evaluate the generic feasibility of geologic storage and retrievability of commercial power reactor spent fuel assemblies in a granitic medium. In addition, the test is configured and instrumented to provide thermal and thermomechanical response data that will be relevant to the design of a repository in hard crystalline rock. The other field activity in the Climax Stock is a radionuclide migration test. It combines a series of field and laboratory migration experiments with the use of existing hydrologic models for pretest predictions and data interpretation. Goals of this project are to develop: (1) field measurement techniques for radionuclide migration studies in a hydrologic regime where the controlling mechanism is fracture permeability; (2) field test data on radionuclide migration; and (3) a comparison of laboratory- and field-measured retardation factors. This radionuclide migration test, which was authorized in the middle of the 1980 fiscal year, is in the preliminary design phase. The detailed program plan was prepared and subjected to formal peer review in August. In September/October researchers conducted preliminary flow tests with water in selected near-vertical fractures intersected by small horizontal boreholes. These tests were needed to establish the range of pressures, flow rates, and other operating parameters to be used in conducting the nuclide migration tests. 21 references, 14 figures, 1 table

  11. Field Lysimeter Test Facility: Second year (FY 1989) test results

    International Nuclear Information System (INIS)

    Campbell, M.D.; Gee, G.W.; Kanyid, M.J.; Rockhold, M.L.

    1990-04-01

    The Record of Decision associated with the Hanford Defense Waste Environmental Impact Statement (53 FR 12449-53) commits to an evaluation of the use of protective barriers placed over near-surface wastes. The barrier must protect against wind and water erosion and limit plant and animal intrusion and infiltration of water. Successful conclusion of this program will yield the necessary protective barrier design for near-surface waste isolation. This report presents results from the second year of tests at the FLTF. The primary objective of testing protective barriers at the FLTF was to measure the water budgets within the various barriers and assess the effectiveness of their designs in limiting water intrusion into the zone beneath each barrier. Information obtained from these measurements is intended for use in refining barrier designs. Four elements of water budget were measured during the year: precipitation, evaporation, storage, and drainage. Run-off, which is a fifth element of a complete water budget, was made negligible by a lip on the lysimeters that protrudes 5 cm above the soil surface to prevent run-off. A secondary objective of testing protective barriers at the FLTF was to refine procedures and equipment to support data collection for verification of the computer model needed for long-term projections of barrier performance. 6 refs

  12. An evaluation of Tsyganenko magnetic field model

    International Nuclear Information System (INIS)

    Fairfield, D.H.

    1991-01-01

    A long-standing goal of magnetospheric physics has been to produce a model of the Earth's magnetic field that can accurately predict the field vector at all locations within the magnetosphere for all dipole tilt angles and for various solar wind or magnetic activity conditions. A number of models make such predictions, but some only for limited spatial regions, some only for zero tilt angle, and some only for arbitrary conditions. No models depend explicitly on solar wind conditions. A data set of more than 22,000 vector averages of the magnetosphere magnetic field over 0.5 R E regions is used to evaluate Tsyganenko's 1982 and 1987 magnetospheric magnetic field models. The magnetic field predicted by the model in various regions is compared to observations to find systematic discrepancies which future models might address. While agreement is generally good, discrepancies are noted which include: (1) a lack of adequate field line stretching in the tail and ring current regions; (2) an inability to predict weak enough fields in the polar cusps; and (3) a deficiency of Kp as a predictor of the field configuration

  13. Field Testing of Environmentally Friendly Drilling System

    Energy Technology Data Exchange (ETDEWEB)

    David Burnett

    2009-05-31

    The Environmentally Friendly Drilling (EFD) program addresses new low-impact technology that reduces the footprint of drilling activities, integrates light weight drilling rigs with reduced emission engine packages, addresses on-site waste management, optimizes the systems to fit the needs of a specific development sites and provides stewardship of the environment. In addition, the program includes industry, the public, environmental organizations, and elected officials in a collaboration that addresses concerns on development of unconventional natural gas resources in environmentally sensitive areas. The EFD program provides the fundamentals to result in greater access, reasonable regulatory controls, lower development cost and reduction of the environmental footprint associated with operations for unconventional natural gas. Industry Sponsors have supported the program with significant financial and technical support. This final report compendium is organized into segments corresponding directly with the DOE approved scope of work for the term 2005-2009 (10 Sections). Each specific project is defined by (a) its goals, (b) its deliverable, and (c) its future direction. A web site has been established that contains all of these detailed engineering reports produced with their efforts. The goals of the project are to (1) identify critical enabling technologies for a prototype low-impact drilling system, (2) test the prototype systems in field laboratories, and (3) demonstrate the advanced technology to show how these practices would benefit the environment.

  14. A field study evaluation of Petrifilm™ plates as a 24-h rapid diagnostic test for clinical mastitis on a dairy farm.

    Science.gov (United States)

    Mansion-de Vries, Elisabeth Maria; Knorr, Nicole; Paduch, Jan-Hendrik; Zinke, Claudia; Hoedemaker, Martina; Krömker, Volker

    2014-03-01

    Clinical mastitis is one of the most common and expensive diseases of dairy cattle. To make an informed treatment decision, it is important to know the causative pathogen. However, no detection of bacterial growth can be made in approximately 30% of all clinical cases of mastitis. Before selecting the treatment regimen, it is important to know whether the mastitis-causing pathogen (MCP) is Gram-positive or Gram-negative. The aim of this field study was to investigate whether using two 3M Petrifilm™ products on-farm (which conveys a higher degree of sample freshness but also bears a higher risk for contamination than working in a lab) as 24-h rapid diagnostic of clinical mastitis achieved results that were comparable to the conventional microbiological diagnostic method. AerobicCount (AC)-Petrifilm™ and ColiformCount (CC)-Petrifilm™ were used to identify the total bacterial counts and Gram-negative bacteria in samples from clinical mastitis cases, respectively. Missing growth on both plates was classified as no bacterial detection. Growth only on the AC-Petrifilm™ was assessed as Gram-positive, and growth on both Petrifilm™ plates was assessed as Gram-negative bacterial growth. Additionally, milk samples were analysed by conventional microbiological diagnostic method on aesculin blood agar as a reference method. Overall, 616 samples from clinical mastitis cases were analysed. Using the reference method, Gram-positive and Gram-negative bacteria, mixed bacterial growth, contaminated samples and yeast were determined in 32.6%, 20.0%, 2.5%, 14.1% and 1.1% of the samples, respectively. In 29.7% of the samples, microbiological growth could not be identified. Using the Petrifilm™ concept, bacterial growth was detected in 59% of the culture-negative samples. The sensitivity of the Petrifilm™ for Gram-positive and Gram-negative MCP was 85.2% and 89.9%, respectively. The specificity was 75.4% for Gram-positive and 88.4% for Gram-negative MCP. For the culture

  15. Automatic system for evaluation of ionizing field

    International Nuclear Information System (INIS)

    Pimenta, N.L.; Calil, S.J.

    1992-01-01

    A three-dimensional cartesian manipulator for evaluating the ionizing field and able to position a ionization chamber in any point of the space is developed. The control system is made using a IBM microcomputer. The system aimed the study of isodose curves from ionizing sources, verifying the performance of radiotherapeutic equipment. (C.G.C.)

  16. Fiscal 2000 report of research on the analysis and evaluation on data collected in project of field test of photovoltaic power generation for public and other facilities; 2000 nendo kokyo shisetsunadoyo taiyoko hatsuden field test jigyo ni okeru shushu data hyoka kaiseki kenkyu hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    For the purpose of promoting photovoltaic power generation, analysis and evaluation were conducted on the data of the project of the field test in public facilities for example. This paper describes the fiscal 2000 results. The equivalent array operation time was 2.98 h/day and, by multiplying it by the output of the standard test condition, a generated output was obtained. The system generating efficiency was 0.102 while the inverter energy efficiency was 0.917 on the average. The average array performance ratio was 0.778 and the system performance ratio was 0.714. The analysis on cost effectiveness of the installed systems has an important bearing upon the future introduction, promotion and development. The power generating cost (the annual cost was calculated as the sum of the capital cost, the direct cost, and the administrative expenses) decreased as the installation year progressed, with the average at the sites installed in fiscal 1997 at 93 yen/kWh. The system cost (calculated by dividing the construction cost by the array capacity) also decreased as the installation year became more recent. The annual maintenance cost showed a wide range from 500 yen to 30,000 yen/kW. Answers from the sites that the systems were running smoothly were 38 to 45%, while those that trouble occurrence was frequent were 2.4% on the generating systems and 12.9% on the measuring systems. (NEDO)

  17. Waste feed delivery test and evaluation plan

    Energy Technology Data Exchange (ETDEWEB)

    O' TOOLE, S.M.

    1999-09-30

    This plan documents the Waste Feed Delivery Program test and evaluation planning and implementation approach. The purpose of this document is to define and communicate the Waste Feed Delivery Program Test and Evaluation scope, objectives, planning and implementation approach.

  18. Waste feed delivery test and evaluation plan

    International Nuclear Information System (INIS)

    O'TOOLE, S.M.

    1999-01-01

    This plan documents the Waste Feed Delivery Program test and evaluation planning and implementation approach. The purpose of this document is to define and communicate the Waste Feed Delivery Program Test and Evaluation scope, objectives, planning and implementation approach

  19. FIELD EVALUATION OF LOW-EMISSION COAL BURNER TECHNOLOGY ON UTILITY BOILERS VOLUME III. FIELD EVALUATIONS

    Science.gov (United States)

    The report gives results of field tests conducted to determine the emission characteristics of a Babcock and Wilcox Circular burner and Dual Register burner (DRB). The field tests were performed at two utility boilers, generally comparable in design and size except for the burner...

  20. Dose-response tests and semi-field evaluation of lethal and sub-lethal effects of slow release pyriproxyfen granules (Sumilarv®0.5G) for the control of the malaria vectors Anopheles gambiae sensu lato.

    Science.gov (United States)

    Mbare, Oscar; Lindsay, Steven W; Fillinger, Ulrike

    2013-03-14

    Recently research has shown that larviciding can be an effective tool for integrated malaria vector control. Nevertheless, the uptake of this intervention has been hampered by the need to re-apply larvicides frequently. There is a need to explore persistent, environmentally friendly larvicides for malaria vector control to reduce intervention efforts and costs by reducing the frequency of application. In this study, the efficacy of a 0.5% pyriproxyfen granule (Surmilarv®0.5G, Sumitomo Chemicals) was assessed for the control of Anopheles gambiae sensu stricto and Anopheles arabiensis, the major malaria vectors in sub-Saharan Africa. Dose-response and standardized field tests were implemented following standard procedures of the World Health Organization's Pesticide Evaluation Scheme to determine: (i) the susceptibility of vectors to this formulation; (ii) the residual activity and appropriate retreatment schedule for field application; and, (iii) sub-lethal impacts on the number and viability of eggs laid by adults after exposure to Sumilarv®0.5G during larval development. Anopheles gambiae s.s. and An. arabiensis were highly susceptible to Sumilarv®0.5G. Estimated emergence inhibition (EI) values were very low and similar for both species. The minimum dosage that completely inhibited adult emergence was between 0.01-0.03 parts per million (ppm) active ingredient (ai). Compared to the untreated control, an application of 0.018 ppm ai prevented 85% (95% confidence interval (CI) 82%-88%) of adult emergence over six weeks under standardized field conditions. A fivefold increase in dosage of 0.09 ppm ai prevented 97% (95% CI 94%-98%) emergence. Significant sub-lethal effects were observed in the standardized field tests. Female An. gambiae s.s. that were exposed to 0.018 ppm ai as larvae laid 47% less eggs, and females exposed to 0.09 ppm ai laid 74% less eggs than females that were unexposed to the treatment. Furthermore, 77% of eggs laid by females exposed to 0

  1. Evaluative Practices in the Culinary Field

    DEFF Research Database (Denmark)

    Christensen, Bo; Strandgaard, Jesper

    This paper is concerned with evaluative practices within the culinary field. The focus is on the evaluative practices performed by two restaurant ranking systems, respectively the Michelin Red Guide system handled by the French tire manufacturer Michelin and the San Pellegrino ’World’s 50 Best...... Restaurant’ list organized by the English based Restaurant Magazine. Both ranking systems evaluate and rate restaurants (judging their food, service, physical setting and so forth) but in different ways through different practices and means, and with somewhat different results....

  2. SMART wind turbine rotor. Design and field test

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Jonathan Charles; Resor, Brian Ray; Paquette, Joshua A.; White, Jonathan Randall

    2014-01-01

    The Wind Energy Technologies department at Sandia National Laboratories has developed and field tested a wind turbine rotor with integrated trailing-edge flaps designed for active control of rotor aerodynamics. The SMART Rotor project was funded by the Wind and Water Power Technologies Office of the U.S. Department of Energy (DOE) and was conducted to demonstrate active rotor control and evaluate simulation tools available for active control research. This report documents the design, fabrication, and testing of the SMART Rotor. This report begins with an overview of active control research at Sandia and the objectives of this project. The SMART blade, based on the DOE / SNL 9-meter CX-100 blade design, is then documented including all modifications necessary to integrate the trailing edge flaps, sensors incorporated into the system, and the fabrication processes that were utilized. Finally the test site and test campaign are described.

  3. Computer-aided dispatch--traffic management center field operational test : state of Utah final report

    Science.gov (United States)

    2006-07-01

    This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch Traffic Management Center Integration Field Operations Test in the State of Utah. The document discusses evaluation findings in the followin...

  4. Computer-aided dispatch--traffic management center field operational test : Washington State final report

    Science.gov (United States)

    2006-05-01

    This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch - Traffic Management Center Integration Field Operations Test in the State of Washington. The document discusses evaluation findings in the foll...

  5. Conducting field studies for testing pesticide leaching models

    Science.gov (United States)

    Smith, Charles N.; Parrish, Rudolph S.; Brown, David S.

    1990-01-01

    A variety of predictive models are being applied to evaluate the transport and transformation of pesticides in the environment. These include well known models such as the Pesticide Root Zone Model (PRZM), the Risk of Unsaturated-Saturated Transport and Transformation Interactions for Chemical Concentrations Model (RUSTIC) and the Groundwater Loading Effects of Agricultural Management Systems Model (GLEAMS). The potentially large impacts of using these models as tools for developing pesticide management strategies and regulatory decisions necessitates development of sound model validation protocols. This paper offers guidance on many of the theoretical and practical problems encountered in the design and implementation of field-scale model validation studies. Recommendations are provided for site selection and characterization, test compound selection, data needs, measurement techniques, statistical design considerations and sampling techniques. A strategy is provided for quantitatively testing models using field measurements.

  6. The Mehrum Coalfire Test Field (MCTF)

    Science.gov (United States)

    Halisch, M.; Wuttke, M. W.; Hesse, Ph.; Han, J.; Kessels, W.

    2009-04-01

    Spontaneous self ignition of coal causes an immense emission of climate relevant gases and affects regional groundwater conditions in such a large scale, that it could not be even rough estimated. This problem occurs all over the world where coal is mined, stored or processed. Keeping these things and also global warming problems in mind, the extinction of such fires becomes a significant task for future climate and environmental protection. In the big arid coal mining belt of the northwest PR China the necessity of environmental as well as resource protection is now realized, leading to increased fire fighting activities. Mostly, the burning coal is partially removed, the surface is insufficiently sealed from oxygen and fire-zones are cooled with valuable fresh water. Such cooling of fire centers is often not sustainable because oxygen rich air may keep on penetrating through the soil surface and reach the cooled down coal which subsequently starts to burn again. Within the Sino-German project "Innovative Technologies for Exploration, Extinction and Monitoring of Coal Fires in North China" numerical models are developed to simulate the propagation of underground coal fires in realistic scenarios. These models will be adapted to new data from lab and field experiments including multiphase transport and phase transition processes. The Mehrum test site is used to set up a small scale in situ coal fire experiment in order to validate and verify the codes as well as to better understand the coal fire genesis. The experiment will be carried out under usage of two coal heaps with a total volume of about 1 m3. At the bottom, a layer of hydraulic conductive coarse gravel has been built in. Within this layer, a special ventilation system for air supplying has been embedded. The exact amount of led in air is measured by high resolution flow rate devices. The coal lies directly above the coarse gravel layer. The heating source is located in the lower forth of the coal layer

  7. The Evaluator Effect in Usability Tests

    DEFF Research Database (Denmark)

    Jacobsen, Niels Ebbe; Hertzum, Morten; John, Bonnie E.

    1998-01-01

    Usability tests are applied in industry to evaluate systems and in research as a yardstick for other usability evaluation methods. However, one potential threat to the reliability of usability tests has been left unaddressed: the evaluator effect. In this study, four evaluators analyzed four vide...

  8. Efficient field testing for load rating railroad bridges

    Science.gov (United States)

    Schulz, Jeffrey L.; Brett C., Commander

    1995-06-01

    As the condition of our infrastructure continues to deteriorate, and the loads carried by our bridges continue to increase, an ever growing number of railroad and highway bridges require load limits. With safety and transportation costs at both ends of the spectrum. the need for accurate load rating is paramount. This paper describes a method that has been developed for efficient load testing and evaluation of short- and medium-span bridges. Through the use of a specially-designed structural testing system and efficient load test procedures, a typical bridge can be instrumented and tested at 64 points in less than one working day and with minimum impact on rail traffic. Various techniques are available to evaluate structural properties and obtain a realistic model. With field data, a simple finite element model is 'calibrated' and its accuracy is verified. Appropriate design and rating loads are applied to the resulting model and stress predictions are made. This technique has been performed on numerous structures to address specific problems and to provide accurate load ratings. The merits and limitations of this approach are discussed in the context of actual examples of both rail and highway bridges that were tested and evaluated.

  9. Field testing of asphalt-emulsion radon-barrier system

    International Nuclear Information System (INIS)

    Hartley, J.N.; Freeman, H.D.; Baker, E.G.; Elmore, M.R.; Nelson, D.A.; Voss, C.F.; Koehmstedt, P.L.

    1981-09-01

    Three years of laboratory and field testing have demonstrated that asphalt emulsion seals are effective radon diffusion barriers. Both laboratory and field tests in 1979, 1980 and 1981 have shown that an asphalt emulsion seal can reduce radon fluxes by greater than 99.9%. The effective diffusion coefficient for the various asphalt emulsion admix seals averages about 10 -6 cm 2 /s. The 1981 joint field test is a culmination of all the technology developed to date for asphalt emulsion radon barrier systems. Preliminary results of this field test and the results of the 1980 field test are presented. 18 figures, 6 tables

  10. Field tests on migration of TRU-nuclide, (2). Migration test for engineered barrier materials in aerated soil

    International Nuclear Information System (INIS)

    Maeda, Toshikatsu; Tanaka, Tadao; Mukai, Masayuki

    2003-01-01

    Field tests on migration of radionuclides for engineered barrier materials such as bentonite and cementitious materials were performed. The tests were run under both wet conditions with artificial rainfall and dry conditions with natural rainfall. Laboratory experiments such as batch adsorption tests were also conducted to analyze the result of field test. The results of field tests agreed with the predicted moisture conditions and the migration behaviors observed at the laboratory experiment that is reported so far. For bentonite material, the movements of the tracer were calculated using known information such as the results of batch sorption tests and migration mechanism. Comparing the result of field test and calculations, it is suggested that tracer migration behavior in bentonite material in field can be evaluated quantitatively by the known migration mechanism and the results of laboratory experiments such as batch sorption test. (author)

  11. FIELD ACCURACY TEST OF RPAS PHOTOGRAMMETRY

    Directory of Open Access Journals (Sweden)

    P. Barry

    2013-08-01

    Full Text Available Baseline Surveys Ltd is a company which specialises in the supply of accurate geospatial data, such as cadastral, topographic and engineering survey data to commercial and government bodies. Baseline Surveys Ltd invested in aerial drone photogrammetric technology and had a requirement to establish the spatial accuracy of the geographic data derived from our unmanned aerial vehicle (UAV photogrammetry before marketing our new aerial mapping service. Having supplied the construction industry with survey data for over 20 years, we felt that is was crucial for our clients to clearly understand the accuracy of our photogrammetry so they can safely make informed spatial decisions, within the known accuracy limitations of our data. This information would also inform us on how and where UAV photogrammetry can be utilised. What we wanted to find out was the actual accuracy that can be reliably achieved using a UAV to collect data under field conditions throughout a 2 Ha site. We flew a UAV over the test area in a "lawnmower track" pattern with an 80% front and 80% side overlap; we placed 45 ground markers as check points and surveyed them in using network Real Time Kinematic Global Positioning System (RTK GPS. We specifically designed the ground markers to meet our accuracy needs. We established 10 separate ground markers as control points and inputted these into our photo modelling software, Agisoft PhotoScan. The remaining GPS coordinated check point data were added later in ArcMap to the completed orthomosaic and digital elevation model so we could accurately compare the UAV photogrammetry XYZ data with the RTK GPS XYZ data at highly reliable common points. The accuracy we achieved throughout the 45 check points was 95% reliably within 41 mm horizontally and 68 mm vertically and with an 11.7 mm ground sample distance taken from a flight altitude above ground level of 90 m.The area covered by one image was 70.2 m × 46.4 m, which equals 0.325 Ha. This

  12. An Electric Field Test Using the MRI

    Czech Academy of Sciences Publication Activity Database

    Fiala, P.; Bartušek, Karel

    2008-01-01

    Roč. 4, č. 7 (2008), s. 701-705 ISSN 1931-7360 Institutional research plan: CEZ:AV0Z20650511 Keywords : MRI * electric field * numerical modeling Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  13. The four-meter confrontation visual field test.

    OpenAIRE

    Kodsi, S R; Younge, B R

    1992-01-01

    The 4-m confrontation visual field test has been successfully used at the Mayo Clinic for many years in addition to the standard 0.5-m confrontation visual field test. The 4-m confrontation visual field test is a test of macular function and can identify small central or paracentral scotomas that the examiner may not find when the patient is tested only at 0.5 m. Also, macular sparing in homonymous hemianopias and quadrantanopias may be identified with the 4-m confrontation visual field test....

  14. Conceptual Design and Requirements for Characterization and Field Test Boreholes: Deep Borehole Field Test

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlman, Kristopher L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brady, Patrick Vane [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); MacKinnon, Robert J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Heath, Jason E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Herrick, Courtney G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jensen, Richard P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rigali, Mark J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hadgu, Teklu [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sevougian, S. David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Birkholzer, Jens [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Freifeld, Barry M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Daley, Tom [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-09-24

    Deep Borehole Disposal (DBD) of high-level radioactive wastes has been considered an option for geological isolation for many years (Hess et al. 1957). Recent advances in drilling technology have decreased costs and increased reliability for large-diameter (i.e., ≥50 cm [19.7”]) boreholes to depths of several kilometers (Beswick 2008; Beswick et al. 2014). These advances have therefore also increased the feasibility of the DBD concept (Brady et al. 2009; Cornwall 2015), and the current field test, introduced herein, is a demonstration of the DBD concept and these advances.

  15. [Test Reviews in Child Psychology: Test Users Wish to Obtain Practical Information Relevant to their Respective Field of Work].

    Science.gov (United States)

    Renner, Gerolf; Irblich, Dieter

    2016-11-01

    Test Reviews in Child Psychology: Test Users Wish to Obtain Practical Information Relevant to their Respective Field of Work This study investigated to what extent diagnosticians use reviews of psychometric tests for children and adolescents, how they evaluate their quality, and what they expect concerning content. Test users (n = 323) from different areas of work (notably social pediatrics, early intervention, special education, speech and language therapy) rated test reviews as one of the most important sources of information. Readers of test reviews value practically oriented descriptions and evaluations of tests that are relevant to their respective field of work. They expect independent reviews that critically discuss opportunities and limits of the tests under scrutiny. The results show that authors of test reviews should not only have a background in test theory but should also be familiar with the practical application of tests in various settings.

  16. Defence Test and Evaluation Roadmap

    Science.gov (United States)

    2008-01-01

    as staff move into new roles in non-T&E organisations. The majority of T&E training is conducted ‘on the job’ and staff turnover (especially with...T&E Issues / Requirements Robotic Combat Systems Determine vulnerability of emerging combat systems to anti- armour robotic systems. Evaluate...Improvised Explosive Devices (IED) Determine capability of armoured & vehicle systems to withstand IED attacks Translate threat scenarios into framework

  17. Aircraft Test & Evaluation Facility (Hush House)

    Data.gov (United States)

    Federal Laboratory Consortium — The Aircraft Test and Evaluation Facility (ATEF), or Hush House, is a noise-abated ground test sub-facility. The facility's controlled environment provides 24-hour...

  18. Superconductor shields test chamber from ambient magnetic fields

    Science.gov (United States)

    Hildebrandt, A. F.

    1965-01-01

    Shielding a test chamber for magnetic components enables it to maintain a constant, low magnetic field. The chamber is shielded from ambient magnetic fields by a lead foil cylinder maintained in a superconducting state by liquid helium.

  19. Test and Evaluation Management Guide, Fifth Edition

    National Research Council Canada - National Science Library

    Claxton, John D; Cavoli, Christina; Johnson, Collie

    2005-01-01

    This January 2005 update to the Defense Acquisition University's "Test and Evaluation Management Guide" includes updates from the Military Services, Defense Agencies, and other organizations, as well...

  20. Dose–response tests and semi-field evaluation of lethal and sub-lethal effects of slow release pyriproxyfen granules (Sumilarv®0.5G) for the control of the malaria vectors Anopheles gambiae sensu lato

    Science.gov (United States)

    2013-01-01

    Background Recently research has shown that larviciding can be an effective tool for integrated malaria vector control. Nevertheless, the uptake of this intervention has been hampered by the need to re-apply larvicides frequently. There is a need to explore persistent, environmentally friendly larvicides for malaria vector control to reduce intervention efforts and costs by reducing the frequency of application. In this study, the efficacy of a 0.5% pyriproxyfen granule (Surmilarv®0.5G, Sumitomo Chemicals) was assessed for the control of Anopheles gambiae sensu stricto and Anopheles arabiensis, the major malaria vectors in sub-Saharan Africa. Methods Dose–response and standardized field tests were implemented following standard procedures of the World Health Organization’s Pesticide Evaluation Scheme to determine: (i) the susceptibility of vectors to this formulation; (ii) the residual activity and appropriate retreatment schedule for field application; and, (iii) sub-lethal impacts on the number and viability of eggs laid by adults after exposure to Sumilarv®0.5G during larval development. Results Anopheles gambiae s.s. and An. arabiensis were highly susceptible to Sumilarv®0.5G. Estimated emergence inhibition (EI) values were very low and similar for both species. The minimum dosage that completely inhibited adult emergence was between 0.01-0.03 parts per million (ppm) active ingredient (ai). Compared to the untreated control, an application of 0.018 ppm ai prevented 85% (95% confidence interval (CI) 82%-88%) of adult emergence over six weeks under standardized field conditions. A fivefold increase in dosage of 0.09 ppm ai prevented 97% (95% CI 94%-98%) emergence. Significant sub-lethal effects were observed in the standardized field tests. Female An. gambiae s.s. that were exposed to 0.018 ppm ai as larvae laid 47% less eggs, and females exposed to 0.09 ppm ai laid 74% less eggs than females that were unexposed to the treatment. Furthermore, 77

  1. Results from laboratory and field testing of nitrate measuring spectrophotometers

    Science.gov (United States)

    Snazelle, Teri T.

    2015-01-01

    Five ultraviolet (UV) spectrophotometer nitrate analyzers were evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) during a two-phase evaluation. In Phase I, the TriOS ProPs (10-millimeter (mm) path length), Hach NITRATAX plus sc (5-mm path length), Satlantic Submersible UV Nitrate Analyzer (SUNA, 10-mm path length), and S::CAN Spectro::lyser (5-mm path length) were evaluated in the HIF Water-Quality Servicing Laboratory to determine the validity of the manufacturer's technical specifications for accuracy, limit of linearity (LOL), drift, and range of operating temperature. Accuracy specifications were met in the TriOS, Hach, and SUNA. The stock calibration of the S::CAN required two offset adjustments before the analyzer met the manufacturer's accuracy specification. Instrument drift was observed only in the S::CAN and was the result of leaching from the optical path insert seals. All tested models, except for the Hach, met their specified LOL in the laboratory testing. The Hach's range was found to be approximately 18 milligrams nitrogen per liter (mg-N/L) and not the manufacturer-specified 25 mg-N/L. Measurements by all of the tested analyzers showed signs of hysteresis in the operating temperature tests. Only the SUNA measurements demonstrated excessive noise and instability in temperatures above 20 degrees Celsius (°C). The SUNA analyzer was returned to the manufacturer at the completion of the Phase II field deployment evaluation for repair and recalibration, and the performance of the sensor improved significantly.

  2. Comparative Study of Frederikshavn Field Tests

    DEFF Research Database (Denmark)

    Firouzianbandpey, Sarah

    This report contains the results and experiences from a large scale test on a bucket foundation located in saturated sand. The experiment is a part of a large research and development program concerning bucket foundations for offshore wind turbines. The research program is a co-operation between...

  3. Inter operability of smart field devices on an open field-bus: from laboratory tests to on-site applications

    International Nuclear Information System (INIS)

    Piguet, M.; Favennec, J.M.

    1997-01-01

    The paper presents a field trial held in EDF's R and D laboratories concerning smart field instruments (sensors, I/O modules, transmitters) operating on the WorldFIP field-bus. The trial put into operation a supervisory control and data acquisition (SCADA) system on the field-bus with available industrial field devices and software tools. The field trial enables EDF's teams to address the inter-operability issue regarding smart field devices and to prepare the forthcoming step from analog to fully digital measurement technology by evaluating new services and higher performances provided. Possible architectures for process control and on-site testing purposes have been identified. A first application for a flow-measuring rig is under way. It implements a WorldFIP field-bus based DCS with FIP/HART multiplexers, FIP and HART smart devices (sensors and actuators) and a field management system. (authors)

  4. Laboratory and field based evaluation of chromatography ...

    Science.gov (United States)

    The Monitor for AeRosols and GAses in ambient air (MARGA) is an on-line ion-chromatography-based instrument designed for speciation of the inorganic gas and aerosol ammonium-nitrate-sulfate system. Previous work to characterize the performance of the MARGA has been primarily based on field comparison to other measurement methods to evaluate accuracy. While such studies are useful, the underlying reasons for disagreement among methods are not always clear. This study examines aspects of MARGA accuracy and precision specifically related to automated chromatography analysis. Using laboratory standards, analytical accuracy, precision, and method detection limits derived from the MARGA chromatography software are compared to an alternative software package (Chromeleon, Thermo Scientific Dionex). Field measurements are used to further evaluate instrument performance, including the MARGA’s use of an internal LiBr standard to control accuracy. Using gas/aerosol ratios and aerosol neutralization state as a case study, the impact of chromatography on measurement error is assessed. The new generation of on-line chromatography-based gas and particle measurement systems have many advantages, including simultaneous analysis of multiple pollutants. The Monitor for Aerosols and Gases in Ambient Air (MARGA) is such an instrument that is used in North America, Europe, and Asia for atmospheric process studies as well as routine monitoring. While the instrument has been evaluat

  5. Field tests of the mobile robot Sherpa

    International Nuclear Information System (INIS)

    Beaucourt, P. de; Garrec, P.; Morganti, P.; Lucibello, P.; Nobile, M.

    1995-01-01

    This paper summarizes recent demonstrations of the transport capabilities, inside nuclear buildings, of the six egged robot SHERPA, developed by the CEA (Atomic Energy Commission) robotic team. Results of the tests carried out at Chooz-B and Trino Vercellesse Nuclear Power Plants, respectively in June 1993 and in January 1994, in the framework of the European Community TELEMAN Programme, are presented. (authors). 10 refs., 13 figs

  6. Field tests of the mobile robot Sherpa

    Energy Technology Data Exchange (ETDEWEB)

    Beaucourt, P. de; Garrec, P.; Morganti, P. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. des Procedes et Systemes Avances; Trouville, B. [Electricite de France (EDF), 78 - Chatou (France); Lucibello, P.; Nobile, M. [ENEA, Rome (Italy). Direzione Studi

    1995-12-31

    This paper summarizes recent demonstrations of the transport capabilities, inside nuclear buildings, of the six egged robot SHERPA, developed by the CEA (Atomic Energy Commission) robotic team. Results of the tests carried out at Chooz-B and Trino Vercellesse Nuclear Power Plants, respectively in June 1993 and in January 1994, in the framework of the European Community TELEMAN Programme, are presented. (authors). 10 refs., 13 figs.

  7. Processing multilevel secure test and evaluation information

    Science.gov (United States)

    Hurlburt, George; Hildreth, Bradley; Acevedo, Teresa

    1994-07-01

    The Test and Evaluation Community Network (TECNET) is building a Multilevel Secure (MLS) system. This system features simultaneous access to classified and unclassified information and easy access through widely available communications channels. It provides the necessary separation of classification levels, assured through the use of trusted system design techniques, security assessments and evaluations. This system enables cleared T&E users to view and manipulate classified and unclassified information resources either using a single terminal interface or multiple windows in a graphical user interface. TECNET is in direct partnership with the National Security Agency (NSA) to develop and field the MLS TECNET capability in the near term. The centerpiece of this partnership is a state-of-the-art Concurrent Systems Security Engineering (CSSE) process. In developing the MLS TECNET capability, TECNET and NSA are providing members, with various expertise and diverse backgrounds, to participate in the CSSE process. The CSSE process is founded on the concepts of both Systems Engineering and Concurrent Engineering. Systems Engineering is an interdisciplinary approach to evolve and verify an integrated and life cycle balanced set of system product and process solutions that satisfy customer needs (ASD/ENS-MIL STD 499B 1992). Concurrent Engineering is design and development using the simultaneous, applied talents of a diverse group of people with the appropriate skills. Harnessing diverse talents to support CSSE requires active participation by team members in an environment that both respects and encourages diversity.

  8. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    Energy Technology Data Exchange (ETDEWEB)

    Susan S. Sorini; John F. Schabron; Joseph F. Rovani, Jr.

    2002-09-30

    Western Research Institute (WRI) has developed a new commercial product ready for technology transfer, the Diesel Dog{reg_sign} Portable Soil Test Kit, for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated as ASTM Method D 5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In June 2001, the Diesel Dog technology won an American Chemical Society Regional Industrial Innovations Award. To gain field experience with the new technology, Diesel Dog kits have been used for a variety of site evaluation and cleanup activities. Information gained from these activities has led to improvements in hardware configurations and additional insight into correlating Diesel Dog results with results from laboratory methods. The Wyoming Department of Environmental Quality (DEQ) used Diesel Dog Soil Test Kits to guide cleanups at a variety of sites throughout the state. ENSR, of Acton, Massachusetts, used a Diesel Dog Portable Soil Test Kit to evaluate sites in the Virgin Islands and Georgia. ChemTrack and the U.S. Army Corps of Engineers successfully used a test kit to guide excavation at an abandoned FAA fuel-contaminated site near Fairbanks, Alaska. Barenco, Inc. is using a Diesel Dog Portable Soil Test Kit for site evaluations in Canada. A small spill of diesel fuel was cleaned up in Laramie, Wyoming using a Diesel

  9. Role of diagnostic tests in esophageal evaluation

    International Nuclear Information System (INIS)

    Silverstein, B.D.; Pope, C.E. II

    1980-01-01

    In the evaluation of esophageal disease, the appropriate question must be asked before the correct tests can be selected. Reflux can be demonstrated by radiologic methods, pH testing or radioisotopic techniques. Esophageal mucosal damage is best evaluated by x-ray, endoscopy, or biopsy. Chest pain is demonstrated by acid infusion or by manometry. Two algorithms are presented for the evaluation of chest pain and reflux symptoms

  10. Including test errors in evaluating surveillance test intervals

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    Technical Specifications require surveillance testing to assure that the standby systems important to safety will start and perform their intended functions in the event of plant abnormality. However, as evidenced by operating experience, the surveillance tests may be adversely impact safety because of their undesirable side effects, such as initiation of plant transients during testing or wearing-out of safety systems due to testing. This paper first defines the concerns, i.e., the potential adverse effects of surveillance testing, from a risk perspective. Then, we present a methodology to evaluate the risk impact of those adverse effects, focusing on two important kinds of adverse impacts of surveillance testing: (1) risk impact of test-caused trips and (2) risk impact of test-caused equipment wear. The quantitative risk methodology is demonstrated with several surveillance tests conducted at boiling water reactors, such as the tests of the main steam isolation valves, the turbine overspeed protection system, and the emergency diesel generators. We present the results of the risk-effectiveness evaluation of surveillance test intervals, which compares the adverse risk impact with the beneficial risk impact of testing from potential failure detection, along with insights from sensitivity studies

  11. Test of QED at critical field strength

    Energy Technology Data Exchange (ETDEWEB)

    Bula, C. [Princeton Univ., NJ (United States)

    1997-01-01

    In a new experiment at the Final Focus Test Beam at SLAC, a low-emittance 46.6 GeV electron beam is brought into collisions with terawatt pulses of 1054 nm or 527 nm wavelength from a Nd:glass laser. Peak laser intensities of 10{sup 18} W/cm{sup 2} have been achieved corresponding to a value of 0.6 for the parameter {eta} = e{epsilon}/m{omega}{sub 0}c. In this case, an electron that crosses the center of the laser pulse has near-unit interaction probability. Results are presented for multiphoton Compton scattering in which an electron interacts with up to four laser photons, in agreement with theoretical calculations.

  12. The Field Lysimeter Test Facility (FLTF) at the Hanford Site: Installation and initial tests

    International Nuclear Information System (INIS)

    Gee, G.W.; Kirkham, R.R.; Downs, J.L.; Campbell, M.D.

    1989-02-01

    The objectives of this program are to test barrier design concepts and to demonstrate a barrier design that meets established performance criteria for use in isolating wastes disposed of near-surface at the Hanford Site. Specifically, the program is designed to assess how well the barriers perform in controlling biointrusion, water infiltration, and erosion, as well as evaluating interactions between environmental variables and design factors of the barriers. To assess barrier performance and design with respect to infiltration control, field lysimeters and small- and large-scale field plots are planned to test the performance of specific barrier designs under actual and modified (enhanced precipitation) climatic conditions. The Field Lysimeter Test Facility (FLTF) is located in the 600 Area of the Hanford Site just east of the 200 West Area and adjacent to the Hanford Meteorological Station. The FLTF data will be used to assess the effectiveness of selected protective barrier configurations in controlling water infiltration. The facility consists of 14 drainage lysimeters (2 m dia x 3 m deep) and four precision weighing lysimeters (1.5 m x 1.5 m x 1.7 m deep). The lysimeters are buried at grade and aligned in a parallel configuration, with nine lysimeters on each side of an underground instrument chamber. The lysimeters were filled with materials to simulate a multilayer protective barrier system. Data gathered from the FLTF will be used to compare key barrier components and to calibrate and test models for predicting long-term barrier performance

  13. Role of energy systems in two intermittent field tests in women field hockey players

    NARCIS (Netherlands)

    Lemmink, Koen A. P. M.; Visscher, Susan H.

    The energetics of 2 field tests that reflect physical performance in intermittent sports (i.e., the Interval Shuttle Sprint Test [ISST] and the Interval Shuttle Run Test [ISRT]) were examined in 21 women field hockey players. The ISST required the players to perform 10 shuttle sprints starting every

  14. Correlação entre testes para avaliação da qualidade de sementes de girassol e emergência das plântulas em campo Correlation between sunflower seeds quality evaluation tests and seedling emergence in field

    Directory of Open Access Journals (Sweden)

    Madelon Rodrigues Sá Braz

    2009-10-01

    Full Text Available A capacidade do teste de germinação para estimar o potencial de emergência de plântulas no campo diminui à medida que as condições do ambiente são desfavoráveis. No entanto, diferentes testes de vigor têm sido utilizados para identificar os lotes de sementes que apresentam melhor desempenho nessas situações. O objetivo do trabalho foi correlacionar os resultados dos testes conduzidos no laboratório com a emergência das plântulas de girassol em campo. Para isso, cinco lotes de sementes de girassol da cultivar 'Embrapa 122 V2000' foram submetidos aos testes de germinação e vigor (primeira contagem, classificação de plântulas, teste de frio, condutividade elétrica, emergência de plântulas em areia e em campo, índice de velocidade de emergência, envelhecimento acelerado e deterioração controlada. Em condições adversas, a emergência das plântulas de girassol em campo apresentou maior correlação com o vigor, avaliado pelos testes de envelhecimento acelerado, de deterioração controlada e de condutividade elétrica.The germination capacity test to estimate the potential of seedlings emergence in the field decreases when the environmental conditions are unfavorable. However, different vigour tests have been used to identify the seed lots that have better perform in these situations. The objective of this research was to correlate the results of tests conducted in the laboratory with the emergence of sunflower seedlings in the field. For this, five lots of seeds sunflower cultivar 'Embrapa 122 V2000' were submitted to the germination and vigour tests (first count, classification of seedlings, cold test, electrical conductivity, seedling emergence in sand and in the field, emergence speed index, accelerated aging and controlled deterioration. Under adverse conditions, the seed vigour evaluated by accelerated aging, controlled deterioration and electrical conductivity presented higher correlation with sunflower plant

  15. Further evaluation in field tests of the activity of three anthelmintics (fenbendazole, oxibendazole, and pyrantel pamoate) against the ascarid Parascaris equorum in horse foals on eight farms in Central Kentucky (2009-2010).

    Science.gov (United States)

    Lyons, Eugene T; Tolliver, Sharon C; Kuzmina, Tetiana A; Collins, Sandra S

    2011-10-01

    The activity of three anthelmintics (fenbendazole-FBZ; oxibendazole-OBZ; and pyrantel pamoate-PRT) was ascertained against the ascarid Parascaris equorum in horse foals on eight farms in Central Kentucky (2009-2010) in field tests. A total of 316 foals were treated, and 168 (53.2%) were passing ascarid eggs on the day of treatment. Evaluation of drug efficacy was determined qualitatively by comparing the number of foals passing ascarid eggs in their feces before and after treatment. The main purpose was to obtain data on current activity of these compounds against ascarids. Additionally, the objective was to compare these findings with those from earlier data on the efficacy of these three compounds on nematodes in foals in this geographical area. Efficacies (average) for the foals ranged for FBZ (10 mg/kg) from 50% to 100% (80%), for OBZ (10 mg/kg) from 75% to 100% (97%), and for PRT at 1× (6.6 mg base/kg) from 0% to 71% (2%) and at 2× (13.2 mg base/kg) 0% to 0% (0%). Although the efficacy varied among the drugs, combined data for all farms indicated a significant reduction of ascarid infections for FBZ (p < 0.0001) and OBZ (p < 0.0001) but not for PRT (p = 0.0953).

  16. Risk effectiveness evaluation of surveillance testing

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    To address the concerns about nuclear power plant surveillance tests, i.e., their adverse safety impact due to negative effects and too burdensome requirements, it is necessary to evaluate the safety significance or risk effectiveness of such tests explicitly considering both negative and positive effects. This paper defines the negative effects of surveillance testing from a risk perspective, and then presents a methodology to quantify the negative risk impact, i.e., the risk penalty or risk increase caused by the test. The method focuses on two important kinds of negative effects, namely, test-caused transients and test-caused equipment degradations. The concepts and quantitative methods for the risk evaluation can be used in the decision-making process to establish the safety significance of the tests and to screen the plant-specific surveillance test requirements. 6 refs., 2 figs., 2 tabs

  17. Evaluation of seismic stability of near field

    International Nuclear Information System (INIS)

    Taniguchi, Wataru; Takaji, Kazuhiko; Sugino, Hiroyuki; Mori, Koji

    1999-11-01

    For the buffer material of geological disposal of high-level radioactive waste (HLW) in Japan, it is considered to use a compacted bentonite or a compacted sand-mixture bentonite that is one kind of clay. The buffer material is expected to maintain long-term mechanical stability, to hold the waste in designated place, and to avoid the effects on the radionuclides migration. It is considered that the cyclic load due to seismic activities affects long-term mechanical stability in Japan, where many earthquakes have been occurring. In this report, aseismic mechanical stability of engineered barrier of HLW is studied by dynamic analysis based on equation of vibration, mainly in the view point of mechanical stability of the buffer. The analytical computer code that has been developed by JNC in cooperative project with National Research Institute for Earth Science and Disaster Prevention Science and Technology Agency is used in this study. Seismic wave at the disposal depth in the assumed geological environment is established by multiple reflection theory analysis, and then seismic wave at the disposal depth is used for the aseismic mechanical stability analysis. For the aseismic mechanical stability, total stress analyses (single-phase system) with the target field of near field are conducted to evaluate the shear failure of the buffer, the displacement of overpack, and vibrational behavior of the engineered barrier, and then effective stress analyses (two-phase system) with the target field of the engineered barrier are conducted to evaluate excursion in the pore water pressure within the buffer (i. e. liquefaction), concerning the non-linear dynamic properties of the buffer material. From the results, the following conclusions are obtained. (1) From the results of the total stress analyses, it is confirmed that the buffer must not reach a shear failure condition from the stresses caused by an earthquake and the overpack must not move significantly due to the inertial

  18. Evaluation of the Field Gradient Lattice Detector

    CERN Document Server

    AUTHOR|(CDS)2072983

    A novel Micro Pattern Gas Detector, named the Field Gradient Lattice Detector, has been implemented using technologies available to CERN’s Printed Circuit Workshop. Numerous prototypes based on various materials were constructed in different geometries and their gain performance has been studied using 55Fe and 109Cd X-ray sources in Argon-CO2 gas mixtures. Two axis (2D) prototype structures have been shown to provide stable gains of around 1000 while a 3D design, based on the same polyimide foils used in other MPGD elements, holds a gain of 5000 for 8.9 keV X-rays even at high rates of 22 kHz/mm2. At a gain of 3100, the device has been tested up to 1 MHz/mm2 and shows no signs of degradation in performance. The energy resolution of the 3D-in-polyimide is modest, around 40% for 5.9 keV X-rays and 30% if the source is collimated indicating a variation in gain over the 3x3 cm2 active area. Having the most promise for future applications, the 3D-in-polyimide design has been selected for testing with a custom-bu...

  19. Toward a model for field-testing patient decision-support technologies: a qualitative field-testing study.

    NARCIS (Netherlands)

    Evans, R.; Elwyn, G.; Edwards, A.; Watson, E.; Austoker, J.; Grol, R.P.T.M.

    2007-01-01

    BACKGROUND: Field-testing is a quality assurance criterion in the development of patient decision-support technologies (PDSTs), as identified in the consensus statement of the International Patient Decision Aids Standards Collaboration. We incorporated field-testing into the development of a

  20. Component evaluation testing and analysis algorithms.

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Darren M.; Merchant, Bion John

    2011-10-01

    The Ground-Based Monitoring R&E Component Evaluation project performs testing on the hardware components that make up Seismic and Infrasound monitoring systems. The majority of the testing is focused on the Digital Waveform Recorder (DWR), Seismic Sensor, and Infrasound Sensor. In order to guarantee consistency, traceability, and visibility into the results of the testing process, it is necessary to document the test and analysis procedures that are in place. Other reports document the testing procedures that are in place (Kromer, 2007). This document serves to provide a comprehensive overview of the analysis and the algorithms that are applied to the Component Evaluation testing. A brief summary of each test is included to provide the context for the analysis that is to be performed.

  1. 1981 radon barrier field test at Grand Junction uranium mill tailings pile

    International Nuclear Information System (INIS)

    Hartley, J.N.; Gee, G.W.; Baker, E.G.; Freeman, H.D.

    1983-04-01

    Technologies to reduce radon released from uranium mill tailings are being investigated by Pacific Northwest Laboratory as part of the Department of Energy's Uranium Mill Tailings Remedial Action Project (UMTRAP) Technology development program. These technologies include: (1) earthen cover systems, (2) multilayer cover systems, and (3) asphalt emulsion radon barrier systems. During the summer of 1981, a field test was initiated at the Grand Junction, Colorado, uranium tailings pile to evaluate and compare the effectiveness of each radon barrier system. Test plots cover about 1.2 ha (3 acres). The field test has demonstrated the effectiveness of all three cover systems in reducing radon release to near background levels ( 2 s - 1 ). In conjunction with the field tests, column tests (1.8 m diameter) were initiated with cover systems similar to those in the larger field test plots. The column tests allow a direct comparison of the two test procedures and also provide detailed information on radon transport

  2. CORRELATION BETWEEN SEED TESTS AND FIELD EMERGENCE OF TWO MAIZE HYBRIDS (SC704 AND SC500)

    OpenAIRE

    A.A. ALILOO; B. SHOKATI

    2011-01-01

    Early emergence and stand establishment of maize (Zea mays L.) are considered to be the most important yield-contributing factors. The influence of seed vigor on these factors is vital. Therefore, five laboratory tests and field experiment were conducted on basis of a randomized complete block design (RCBD) with five replications in 2011, to evaluate the correlation among the seed vigor tests and field emergence of two maize hybrids (SC704 and SC500). In laboratory tests, differences between ...

  3. Development and manufacture of a Nb3Sn superconductor for the high-field test facility

    International Nuclear Information System (INIS)

    Scanlan, R.M.; Cornish, D.N.; Spencer, C.R.; Gregory, E.; Adam, E.

    1981-01-01

    The High-Field Test Facility (HFTF) project has two primary goals. The first is to establish manufacturing capability for a Nb 3 Sn conductor suitable for use in a mirror fusion coil. The second is to provide a test facility for evaluating other fusion conductor designs at high fields. This paper describes some of the problems encountered and the solutions devised in working toward the first goal. Construction of the test facility coils will be described in a subsequent paper

  4. Fiscal 1996 research report on the PV power generation field test project for public facilities. Evaluation and analysis of collected data for every site (1/2); 1996 nendo kokyo shisetsu nadoyo taiyoko hatsuden field test jigyo ni okeru shushu data hyoka kaiseki. Kaku site betsu (1/2)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    As a part of the PV power generation field test project, this report summarizes the monthly collected data for every site in fiscal 1996. The test sites include various public facilities such as park, school, university, museum, Shinkansen platform, laboratory, technical center, training building, local governmental hotel, health athletic center, community center, joint purchase center, consumers' cooperative (CO-OP), school meals provision center, prefectural office building, police station garage, water purification plant, general disaster prevention center, and health center. Collected data items are as follows: total solar irradiation (kWh/m{sup 2}), average air temperature, array power, system power, load power, power system supply load, reverse power flow, self supply load (kWh for every item), system disinterconnection time (min), system operation time (min), equivalent array/system operation time, array/system performance ratio, system use factor, system generation efficiency, effective inverter efficiency, and inverter load factor. (NEDO)

  5. Student Tests for Teacher Evaluation: A Critique.

    Science.gov (United States)

    Florio, David H.

    1986-01-01

    This article supports Edward Haertel's views on inappropriate use of student test scores in evaluating teachers. Tests scores may identify a few incompetent teachers, but may bring new ailments to schools. The article argues that even the system proposed by Haertal may become subject to abuse by mechanistic or autocratic administrative practices.…

  6. Testing and evaluation of light ablation decontamination

    International Nuclear Information System (INIS)

    Demmer, R.L.; Ferguson, R.L.

    1994-10-01

    This report details the testing and evaluation of light ablation decontamination. It details WINCO contracted research and application of light ablation efforts by Ames Laboratory. Tests were conducted with SIMCON (simulated contamination) coupons and REALCON (actual radioactive metal coupons) under controlled conditions to compare cleaning effectiveness, speed and application to plant process type equipment

  7. Marihuana contact test, evaluation and development

    Science.gov (United States)

    1976-02-01

    A colorimetric swab test for detecting human contact with marihuana was evaluated. The test was found to be capable of detecting only 83% of marihuana smokers immediately after smoking and was also demonstrated to be subject to a wide range of possib...

  8. Glass microspheres covering film: first field evaluations

    International Nuclear Information System (INIS)

    Magnani, G.; Filippi, F.

    2006-01-01

    A trial was carried out to evaluate, in the North-Centre of Italy, the behaviour in field of a new plastic covering film, prepared with the inclusion of empty glass microspheres (Solex). The trial was conducted on tomato (Lycopersicon esculentum L.) and eggplant (Solanum melongena L.). The new film was compared to a covering film with the same optical (diffuse light) and constitutional (co-extruded three layers EVA-WPE) characteristics. Since the first results, the innovative film showed a better behaviour than the control one. It presented light and thermal conditions (lower temperature during the day and slightly higher temperature in the night, compared to the control film) that allowed a better growth and yield than the control film. The growth analysis of tomato showed that plants grown under glass microsphere film had an higher growth rate (dry weight/days) and thickness of leaves compared to the control one. The yield of tomato and eggplant presented an increase in plants cultivated under the innovative film, especially for number and weight of fruits. The commercial quality did not show any differences between the films, except for the flesh hardness of tomato: this could be explained with the fact that the glass microspheres film provides environmental conditions avoiding plant stress during some stages of its cycle [it

  9. Evaluation of pavement joint sealants :a new testing technique

    OpenAIRE

    Abo-Qudais, Saad A.

    1992-01-01

    A new method to evaluate the performance of sealants, used in rigid pavement joints, was developed. A special fixture was designed to transfer cyclic in-line deflection, applied by a testing machine, to cyclic normal and shear deflections on a sealant sandwiched between two-2 x 2 x 2 in. portland cement mortar cubes. The normal and shear deflections were applied simultaneously at a specific ratio controlled by the developed fixture. The new testing method simulates field ...

  10. Field Testing Research at the NWTC (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2015-02-01

    The National Wind Technology Center (NWTC) at the National Renewable Laboratory (NREL) has extensive field testing capabilities that have been used in collaboration with the wind industry to accelerate wind technology development and deployment for more than 30 years.

  11. AFSC/FMA/NPRB Halibut Bycatch Video Field Test

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data arise from a field test of electronic monitoring (EM) of vessels participating in the Pacific halibut fishery off Alaska. A side-by-side comparison was...

  12. Travel Time Data Collection Field Tests - Lessons Learned

    Science.gov (United States)

    1999-06-28

    The Los Angeles Spread Spectrum Radio (SSR) Traffic Signal Interconnect Field Operational Test (FOT) investigated the feasibility of using wireless communications as an alternative to traditional hard-wire interconnection, to extend the coverage of c...

  13. Instructions for 104-SX liquid level measurement field tests

    International Nuclear Information System (INIS)

    Webb, R.H.

    1994-01-01

    This document provides detailed instructions for field testing a suggested solution of inserting a liner inside the 104-SX failed Liquid Observation Well to gain access for making temporary Liquid Level Measurement until a permanent solution has been provided

  14. Remote field eddy current testing of ferromagnetic tubes

    International Nuclear Information System (INIS)

    David, B.

    1990-01-01

    In order to test ferromagnetic tubes using internal probes, Intercontrole and the CEA have carried out theoretical and experimental works and developed a method to adapt the Remote Field Eddy Current technique which has been known and used for 30 years now. This document briefly recalls the basic principles of the Remote Field Eddy Current technique, the various steps of the works carried out and mainly describes examples of field inspection of ferromagnetic tubes and pipes [fr

  15. Field tests and commercialization of natural gas leak detectors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, D S; Jeon, J S; Kim, K D; Cho, Y A [R and D Center, Korea Gas Corporation, Ansan (Korea)

    1999-09-01

    Objectives - (1) fields test of industrial gas leak detection monitoring system. (2) commericialization of residential gas leak detector. Contents - (1) five sets of gas leak detection monitoring system were installed at natural gas transmition facilities and tested long term stability and their performance. (2) improved residential gas leak detector was commercialised. Expected benefits and application fields - (1) contribution to the improvement of domestic gas sensor technology. (2) localization of fabrication technology for gas leak detectors. 23 refs., 126 figs., 37 tabs.

  16. Superconductors for fusion magnets tested under pulsed field in SULTAN

    International Nuclear Information System (INIS)

    Bruzzone, P.; Bottura, L.; Katheder, H.; Blau, B.; Rohleder, I.; Vecsey, G.

    1995-01-01

    The SULTAN III test facility has been upgraded with a pair of pulsed field coils to carry out AC losses and stability experiments under full operating loads on large size, fusion conductors for ITER. A fast data aquisition system records the conductor behaviour under fast field transient. The commissioning results of the pulsed coils and instrumentation are critically discussed and the test capability of the set up is assessed. (orig.)

  17. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2001-05-31

    Western Research Institute (WRI) is commercializing Diesel Dog Portable Soil Test Kits for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated ASTM Method D-5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In FY 99, twenty-five preproduction kits were successfully constructed in cooperation with CF Electronics, Inc., of Laramie, Wyoming. The kit components work well and the kits are fully operational. In the calendar year 2000, kits were provided to the following entities who agreed to participate as FY 99 and FY 00 JSR (Jointly Sponsored Research) cosponsors and use the kits as opportunities arose for field site work: Wyoming Department of Environmental Quality (DEQ) (3 units), F.E. Warren Air Force Base, Gradient Corporation, The Johnson Company (2 units), IT Corporation (2 units), TRC Environmental Corporation, Stone Environmental, ENSR, Action Environmental, Laco Associates, Barenco, Brown and Caldwell, Dames and Moore Lebron LLP, Phillips Petroleum, GeoSyntek, and the State of New Mexico. By early 2001, ten kits had been returned to WRI following the six-month evaluation period. On return, the components of all ten kits were fully functional. The kits were upgraded with circuit modifications, new polyethylene foam inserts, and updated instruction manuals.

  18. Testing of a one dimensional model for Field II calibration

    DEFF Research Database (Denmark)

    Bæk, David; Jensen, Jørgen Arendt; Willatzen, Morten

    2008-01-01

    Field II is a program for simulating ultrasound transducer fields. It is capable of calculating the emitted and pulse-echoed fields for both pulsed and continuous wave transducers. To make it fully calibrated a model of the transducer’s electro-mechanical impulse response must be included. We...... examine an adapted one dimensional transducer model originally proposed by Willatzen [9] to calibrate Field II. This model is modified to calculate the required impulse responses needed by Field II for a calibrated field pressure and external circuit current calculation. The testing has been performed...... to the calibrated Field II program for 1, 4, and 10 cycle excitations. Two parameter sets were applied for modeling, one real valued Pz27 parameter set, manufacturer supplied, and one complex valued parameter set found in literature, Alguer´o et al. [11]. The latter implicitly accounts for attenuation. Results show...

  19. Field vibration test of principal equipment of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Shiraki, Kazuhiro; Fujita, Katsuhisa; Kajimura, Motohiko; Ikegami, Yasuhiko; Hanzawa, Katsumi; Sakai, Yoshiyuki; Kokubo, Eiji; Igarashi, Shigeru

    1984-09-01

    Japan is one of the most earthquake-stricken countries in the world, and demands for aseismic design have become severer recently. In a nuclear power plant in particular, consisting of a reactor vessel and other facilities dealing with a radioactive substance in some form or other, it is essential from the standpoint of safety to eliminate any possibility of radioactive hazards for the local public, and the employees at the plant as well, if these facilities are struck by an earthquake. This paper is related to the reactor vessel, reactor primary cooling equipment and piping system and important general piping as examples of important facilities of a nuclear power plant, and discusses vibration tests of an actual plant in the field from the standpoint of enhancing the aseismic safety of the Mitsubishi PWR nuclear power plant. Especially concerning vibration test technology, the effects in the evaluation of aseismic safety and its limits are studied to prove how it contributes to the enhancement of the reliability of aseismic design of nuclear power plants.

  20. Educational Evaluation: The State of the Field.

    Science.gov (United States)

    Wolf, Richard M., Ed.

    1987-01-01

    Educational evaluation is discussed. Topics include: an evaluation framework, educational objectives and study design from a 20-year perspective, a sample study, educational evaluation for local school improvement, decision-oriented evaluation studies, reporting study results, and professional standards for assuring the quality of educational…

  1. Influence of the magnetic field profile on ITER conductor testing

    International Nuclear Information System (INIS)

    Nijhuis, A; Ilyin, Y; Kate, H H J ten

    2006-01-01

    We performed simulations with the numerical CUDI-CICC code on a typical short ITER (International Thermonuclear Experimental Reactor) conductor test sample of dual leg configuration, as usually tested in the SULTAN test facility, and made a comparison with the new EFDA-Dipole test facility offering a larger applied DC field region. The new EFDA-Dipole test facility, designed for short sample testing of conductors for ITER, has a homogeneous high field region of 1.2 m, while in the SULTAN facility this region is three times shorter. The inevitable non-uniformity of the current distribution in the cable, introduced by the joints at both ends, has a degrading effect on voltage-current (VI) and voltage-temperature (VT) characteristics, particularly for these short samples. This can easily result in an underestimation or overestimation of the actual conductor performance. A longer applied DC high field region along a conductor suppresses the current non-uniformity by increasing the overall longitudinal cable electric field when reaching the current sharing mode. The numerical interpretation study presented here gives a quantitative analysis for a relevant practical case of a test of a short sample poloidal field coil insert (PFCI) conductor in SULTAN. The simulation includes the results of current distribution analysis from self-field measurements with Hall sensor arrays, current sharing measurements and inter-petal resistance measurements. The outcome of the simulations confirms that the current uniformity improves with a longer high field region but the 'measured' VI transition is barely affected, though the local peak voltages become somewhat suppressed. It appears that the location of the high field region and voltage taps has practically no influence on the VI curve as long as the transverse voltage components are adequately cancelled. In particular, for a thin conduit wall, the voltage taps should be connected to the conduit in the form of an (open) azimuthally

  2. FY 1998 evaluation/analysis by site of the data collected in the field test project for photovoltaic power generation for public facilities. 4/4; 1998 nendo kokyo shisetsu nadoyo taiyoko hatsuden field test jigyo ni okeru shushu data hyoka kaiseki kaku site betsu. 4/4

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    The data items are horizontal insolation intensity, inclined insolation intensity, effective inclined insolation intensity (each unit: kWh/m{sup 2}), average temperature, array power energy, system power energy, system consumption power, load power energy, system supply load, and back flow power energy (each unit: kWh). Besides, the number of interconnected protective movement, disconnection hour (minute), system operating hour (minute), independent operating load, independent supply load (each unit: kWh), equivalent array operating hour, equivalent system operating hour, array/system output coefficient, system utilization rate/power generation rate, INV effective efficiency, and INV load factor. The objects of field tests are government office (joint office building, etc.), school (college, high school, elementary school, etc.), the Shinkansen Kyoto Station, health/welfare facilities (health facilities for the elderly, welfare center, etc.), hospital, industrial experimental station, training facilities (exhibition training facilities, etc.), broadcasting facilities, etc. (NEDO)

  3. Accurate evaluation of exchange fields in finite element micromagnetic solvers

    Science.gov (United States)

    Chang, R.; Escobar, M. A.; Li, S.; Lubarda, M. V.; Lomakin, V.

    2012-04-01

    Quadratic basis functions (QBFs) are implemented for solving the Landau-Lifshitz-Gilbert equation via the finite element method. This involves the introduction of a set of special testing functions compatible with the QBFs for evaluating the Laplacian operator. The results by using QBFs are significantly more accurate than those via linear basis functions. QBF approach leads to significantly more accurate results than conventionally used approaches based on linear basis functions. Importantly QBFs allow reducing the error of computing the exchange field by increasing the mesh density for structured and unstructured meshes. Numerical examples demonstrate the feasibility of the method.

  4. Differential Gender Performance on the Major Field Test-Business

    Science.gov (United States)

    Bielinska-Kwapisz, Agnieszka; Brown, F. William

    2013-01-01

    The Major Field Test in Business (MFT-B), a standardized assessment test of business knowledge among undergraduate business seniors, is widely used to measure student achievement. Many previous studies analyzing scores on the MFT-B report gender differences on the exam even after controlling for student's aptitude, general intellectual ability,…

  5. The advanced test reactor strategic evaluation program

    International Nuclear Information System (INIS)

    Buescher, B.J.

    1989-01-01

    Since the Chernobly accident, the safety of test reactors and irradiation facilities has been critically evaluated from the public's point of view. A systematic evaluation of all safety, environmental, and operational issues must be made in an integrated manner to prioritize actions to maximize benefits while minimizing costs. Such a proactive program has been initiated at the Advanced Test Reactor (ATR). This program, called the Strategic Evaluation Program (STEP), is being conducted for the ATR to provide integrated safety and operational reviews of the reactor against the standards applied to licensed commercial power reactors. This has taken into consideration the lessons learned by the US Nuclear Regulatory Commission (NRC) in its Systematic Evaluation Program (SEP) and the follow-on effort known as the Integrated Safety Assessment Program (ISAP). The SEP was initiated by the NRC to review the designs of older operating nuclear power plants to confirm and document their safety. The ATR STEP objectives are discussed

  6. Qualifying tests for TRIAM-1M superconducting toroidal magnetic field coil

    Energy Technology Data Exchange (ETDEWEB)

    Nakanura, Yukio; Hiraki, Naoji; Nakamura, Kazuo; Tanaka, Masayoshi; Nagao, Akihiro; Kawasaki, Shoji; Itoh, Satoshi

    1984-09-01

    In the strong toroidal magnetic field experimental facility ''TRIAM-1M'' currently under construction, construction of the superconducting toroidal magnetic field coil and the following qualifying tests conducted on the full-scale superconducting toroidal magnetic field coil actually fabricated are described: (1) coil excitation test, (2) superconducting stability test, (3) external magnetic field application test, and (4) high-speed excitation test. On the basis of these test results, stability was evaluated of the superconducting coil being operated in the tokamak device. In normal tokamak operation, there occurs no normal conduction transition. At the time of plasma disruption, though this transition takes place in part of the coil, the superconducting state is immediately restored. By its electromagnetic force analysis, the superconducting coil is also stable in structure.

  7. Field testing for cosmic ray soft errors in semiconductor memories

    International Nuclear Information System (INIS)

    O'Gorman, T.J.; Ross, J.M.; Taber, A.H.; Ziegler, J.F.; Muhlfeld, H.P.; Montrose, C.J.; Curtis, H.W.; Walsh, J.L.

    1996-01-01

    This paper presents a review of experiments performed by IBM to investigate the causes of soft errors in semiconductor memory chips under field test conditions. The effects of alpha-particles and cosmic rays are separated by comparing multiple measurements of the soft-error rate (SER) of samples of memory chips deep underground and at various altitudes above the earth. The results of case studies on four different memory chips show that cosmic rays are an important source of the ionizing radiation that causes soft errors. The results of field testing are used to confirm the accuracy of the modeling and the accelerated testing of chips

  8. Fiscal 1997 research report on the PV power generation field test project for public facilities. Evaluation and analysis of collected data for every site (2/3); 1997 nendo kokyo shisetsu nadoyo taiyoko hatsuden field test jigyo ni okeru shushu data hyoka kaiseki. Kaku site betsu (2/3)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    As a part of the PV power generation field test project, this report summarizes the monthly collected data for every site in fiscal 1996. Collected data items are as follows: horizontal/total/effective solar irradiation (kWh/m{sup 2}), average air temperature, array power, system power, load power, power system supply load, reverse power flow (kWh for every item), power system protective operation frequency, system disinterconnection time (min), system operation time (min), self-operation load, self-supply load, equivalent array/system operation time, array/system performance ratio, system use factor, system generation efficiency, effective inverter efficiency, and inverter load factor. The test sites include various public facilities such as doctor's office, newspaper office, general building for public corporations, primary school, hot water pool, health center, public hall, town/ward office, water purification plant, consumers' cooperative (CO-OP), university, high school, technical center, training center, nursery school, kindergarten, and nursing home for the aged. (NEDO)

  9. Field evaluation of a fast anti-Leishmania antibody detection assay in Ethiopia

    NARCIS (Netherlands)

    Hailu, A.; Schoone, G. J.; Diro, E.; Tesfaye, A.; Techane, Y.; Tefera, T.; Assefa, Y.; Genetu, A.; Kebede, Y.; Kebede, T.; Schallig, H. D. F. H.

    2006-01-01

    A fast agglutination screening test (FAST) for the detection of Leishmania antibodies in human serum samples was evaluated under harsh field conditions in northern Ethiopia. Test performance was compared with a standard serological test, namely the direct agglutination test (DAT), and with

  10. Field Tests of the HYDAD-D Landmine Detector

    International Nuclear Information System (INIS)

    Brooks, F.D.; Drosg, M.; Smit, F.D.

    2010-01-01

    The HYDAD-D landmine detector has been field tested in South Africa and in Egypt, using both a dummy landmine and real (disabled) anti-personnel landmines. A hand-held version of the detector and a version that incorporates a motor-driven scanner were tested. The test results demonstrate that HYDAD-D can detect the VS 50 anti-personnel landmine (mass 185 g) when buried at a cover depth of 20 cm in dry sand. (author)

  11. Field Lysimeter Test Facility status report IV: FY 1993

    International Nuclear Information System (INIS)

    Gee, G.W.; Felmy, D.G.; Ritter, J.C.; Campbell, M.D.; Downs, J.L.; Fayer, M.J.; Kirkham, R.R.; Link, S.O.

    1993-10-01

    At the U.S. Department of Energy's Hanford Site near Richland, Washington, a unique facility, the Field Lysimeter Test Facility (FLTF) is used to measure drainage from and water storage in soil covers. Drainage has ranged from near zero amounts to more than 50% of the applied water, with the amount depending on vegetative cover and soil type. Drainage occurred from lysimeters with coarse soils and gravel covers, but did not occur from capillary barrier-type lysimeters (1.5 m silt loam soil over coarse sands and gravels) except under the most extreme condition tested. For capillary barriers that were irrigated and kept vegetation-free (bare surface), no drainage occurred in 5 of the past 6 years. However, this past year (1992--1993) a record snowfall of 1,425 mm occurred and water storage in the irrigated, bare-surfaced capillary barriers exceeded 500 mm resulting in drainage of more than 30 mm from these barriers. In contrast, capillary barriers, covered with native vegetation (i.e., shrubs and grasses) did not drain under any climatic condition (with or without irrigation). In FY 1994, the FLTF treatments will be increased from 11 to 17 with the addition of materials that will simulate portions of a prototype barrier planned for construction in 1994 at the Hanford Site. The 17 FLTF treatments are designed to test the expected range of surface soil, vegetation, and climatic conditions encountered at the Hanford Site and will assist in evaluating final surface barrier designs for a waste disposal facility

  12. Testing of Photomultiplier Tubes in a Magnetic Field

    Science.gov (United States)

    Waldron, Zachary; A1 Collaboration

    2016-09-01

    The A1 collaboration at MAMI in Mainz, Germany has designed a neutron detector that can be used in experiments to measure the electric form factor of the neutron. They will measure elastic scattering from the neutron, using the polarized electron beam from MAMI at A1's experimental hall. The detector will be composed of two walls of staggered scintillator bars which will be read out by photomultiplier tubes (PMT), connected to both ends of each scintillator via light guides. The experiment requires a magnetic field with strength of 1 Tesla, 2m away from the first scintillator wall. The resulting fringe field is sufficient to disrupt the PMTs, despite the addition of Mu Metal shielding. The effects of the fringe field on these PMTs was tested to optimize the amplification of the PMTs. A Helmholtz Coil was designed to generate a controlled magnetic field with equivalent strength to the field that the PMTs will encounter. The PMTs were read out using a multi-channel analyzer, were tested at various angles relative to the magnetic field in order to determine the optimal orientation to minimize signal disruption. Tests were also performed to determine: the neutron detector response to cosmic radiation; and the best method for measuring a magnetic field's strength in two dimensions. National Science Foundation Grant No. IIA-1358175.

  13. Model to Test Electric Field Comparisons in a Composite Fairing Cavity

    Science.gov (United States)

    Trout, Dawn H.; Burford, Janessa

    2013-01-01

    Evaluating the impact of radio frequency transmission in vehicle fairings is important to sensitive spacecraft. This study shows cumulative distribution function (CDF) comparisons of composite a fairing electromagnetic field data obtained by computational electromagnetic 3D full wave modeling and laboratory testing. This work is an extension of the bare aluminum fairing perfect electric conductor (PEC) model. Test and model data correlation is shown.

  14. CMOS test and evaluation a physical perspective

    CERN Document Server

    Bhushan, Manjul

    2015-01-01

    This book extends test structure applications described in Microelectronic Test Struc­tures for CMOS Technology (Springer 2011) to digital CMOS product chips. Intended for engineering students and professionals, this book provides a single comprehensive source for evaluating CMOS technology and product test data from a basic knowledge of the physical behavior of the constituent components. Elementary circuits that exhibit key properties of complex CMOS chips are simulated and analyzed, and an integrated view of design, test and characterization is developed. Appropriately designed circuit monitors embedded in the CMOS chip serve to correlate CMOS technology models and circuit design tools to the hardware and also aid in test debug. Impact of silicon process variability, reliability, and power and performance sensitivities to a range of product application conditions are described. Circuit simulations exemplify the methodologies presented, and problems are included at the end of the chapters.

  15. Vadose zone transport field study: Detailed test plan for simulated leak tests

    International Nuclear Information System (INIS)

    AL Ward; GW Gee

    2000-01-01

    : identify mechanisms controlling transport processes in soils typical of the hydrogeologic conditions of Hanford's waste disposal sites; reduce uncertainty in conceptual models; develop a detailed and accurate database of hydraulic and transport parameters for validation of three-dimensional numerical models; identify and evaluate advanced, cost-effective characterization methods with the potential to assess changing conditions in the vadose zone, particularly as surrogates of currently undetectable high-risk contaminants. This plan provides details for conducting field tests during FY 2000 to accomplish these objectives. Details of additional testing during FY 2001 and FY 2002 will be developed as part of the work planning process implemented by the Integration Project

  16. Improvement of test methodology for evaluating diesel fuel stability

    Energy Technology Data Exchange (ETDEWEB)

    Gutman, M.; Tartakovsky, L.; Kirzhner, Y.; Zvirin, Y. [Internal Combustion Engines Lab., Haifa (Israel); Luria, D. [Fuel Authority, Tel Aviv (Israel); Weiss, A.; Shuftan, M. [Israel Defence Forces, Tel Aviv (Israel)

    1995-05-01

    The storage stability of diesel fuel has been extensively investigated for many years under laboratory conditions. Although continuous efforts have been made to improve testing techniques, there does not yet exist a generally accepted correlation between laboratory methods (such as chemical analysis of the fuel) and actual diesel engine tests. A testing method was developed by the Technion Internal Combustion Engines Laboratory (TICEL), in order to address this problem. The test procedure was designed to simulate diesel engine operation under field conditions. It is based on running a laboratory-modified single cylinder diesel engine for 50 h under cycling operating conditions. The overall rating of each test is based on individual evaluation of the deposits and residue formation in the fuel filter, nozzle body and needle, piston head, piston rings, exhaust valve, and combustion chamber (six parameters). Two methods for analyzing the test results were used: objective, based on measured data, and subjective, based on visual evaluation results of these deposits by a group of experts. Only the residual level in the fuel filter was evaluated quantitatively by measured results. In order to achieve higher accuracy of the method, the test procedure was improved by introducing the measured results of nozzle fouling as an additional objective evaluating (seventh) parameter. This factor is evaluated on the basis of the change in the air flow rate through the nozzle before and after the complete engine test. Other improvements in the method include the use of the nozzle assembly photograph in the test evaluation, and representation of all seven parameters on a continuous scale instead of the discrete scale used anteriorly, in order to achieve higher accuracy. This paper also contains the results obtained by application of this improved fuel stability test for a diesel fuel stored for a five-year period.

  17. A convenient procedure for magnetic field homogeneity evaluation

    International Nuclear Information System (INIS)

    Teles, J; Garrido, C E; Tannus, A

    2004-01-01

    In many areas of research that utilize magnetic fields in their studies, it is important to obtain fields with a spatial distribution as homogeneous as possible. A procedure usually utilized to evaluate and to optimize field homogeneity is the expansion of the measured field in spherical harmonic components. In addition to the methods proposed in the literature, we present a more convenient procedure for evaluation of field homogeneity inside a spherical volume. The procedure uses the orthogonality property of the spherical harmonics to find the field variance. It is shown that the total field variance is equal to the sum of the individual variances of each field component in the spherical harmonic expansion. Besides the advantages of the linear behaviour of the individual variances, there is the fact that the field variance and standard deviation are the best parameters to achieve global homogeneity field information

  18. Pressure test method for reactor pressure vessel in construction field

    International Nuclear Information System (INIS)

    Takeda, Masakado; Ushiroda, Koichi; Miyahara, Ryohei; Takano, Hiroshi; Matsuura, Tadashi; Sato, Keiya.

    1998-01-01

    Plant constitutional parts as targets of both of a primary pressure test and a secondary pressure test are disposed in communication with a reactor pressure vessel, and a pressure of the primary pressure test is applied to the targets of both tests, so that the primary pressure test and the second pressure test are conducted together. Since the number of pressure tests can be reduced to promote construction, and the number of workers can also be reduced. A pressure exceeding the maximum pressure upon use is applied to the pressure vessel after disposing the incore structures, to continuously conduct the primary pressure test and the secondary pressure test joined together and an incore flowing test while closing the upper lid of the pressure vessel as it is in the construction field. The number of opening/closing of the upper lid upon conducting every test can be reduced, and since the pressure resistance test is conducted after arranging circumference conditions for the incore flowing test, the tests can be conducted collectively also in view of time. (N.H.)

  19. Field evaluation of a PfHRP-2/pLDH rapid diagnostic test and light microscopy for diagnosis and screening of falciparum malaria during the peak seasonal transmission in an endemic area in Yemen.

    Science.gov (United States)

    Alareqi, Lina M Q; Mahdy, Mohammed A K; Lau, Yee-Ling; Fong, Mun-Yik; Abdul-Ghani, Rashad; Ali, Arwa A; Cheong, Fei-Wen; Tawfek, Rehab; Mahmud, Rohela

    2016-01-28

    Malaria is a public health threat in Yemen, with 149,451 cases being reported in 2013. Of these, Plasmodium falciparum represents 99%. Prompt diagnosis by light microscopy (LM) and rapid diagnostic tests (RTDs) is a key element in the national strategy of malaria control. The heterogeneous epidemiology of malaria in the country necessitates the field evaluation of the current diagnostic strategies, especially RDTs. Thus, the present study aimed to evaluate LM and an RDT, combining both P. falciparum histidine-rich protein-2 (PfHRP-2) and Plasmodium lactate dehydrogenase (pLDH), for falciparum malaria diagnosis and survey in a malaria-endemic area during the transmission season against nested polymerase chain reaction (PCR) as the reference method. A household-based, cross-sectional malaria survey was conducted in Mawza District, a malaria-endemic area in Taiz governorate. A total of 488 participants were screened using LM and PfHRP-2/pLDH RDT. Positive samples (160) and randomly selected negative samples (52) by both RDT and LM were further analysed using 18S rRNA-based nested PCR. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the RDT were 96.0% (95% confidence interval (CI): 90.9-98.3), 56.0% (95% CI: 44.7-66.8), 76.3% (95% CI: 69.0-82.3), and 90.4% (95% CI: 78.8-96.8), respectively. On the other hand, LM showed sensitivity of 37.6% (95% CI: 29.6-46.3), specificity of 97.6% (95% CI: 91.7-99.7), PPV of 95.9% (95% CI: 86.3-98.9), and NPV of 51.3% (95% CI: 43.2-59.2). The sensitivity of LM dropped to 8.5% for detecting asymptomatic malaria. Malaria prevalence was 32.8% (32.1 and 37.5% for ≥10 and <10 years, respectively) with the RDT compared with 10.7% (10.8 and 9.4% for age groups of ≥10 and <10 years, respectively) with LM. Among asymptomatic malaria individuals, LM and RDT-based prevalence rates were 1.6 and 25.6%, respectively. However, rates of 88.2 and 94.1% of infection with P. falciparum were found

  20. A Field Test of the New Portable Gamma Spectrometry System

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Jung-Ki; Park, Uk Ryang; Park, Seunghoon; Chung, Heejun; Kwak, Sung-Woo [Korea Institute of Nuclear Non-proliferation and Control, Daejeon (Korea, Republic of); Kim, Yongkwn [NuCare Medical Systems, Inc., Incheon (Korea, Republic of)

    2015-10-15

    In order to perform a field test of the system, the measurement of U-235 enrichment for nuclear fuel pellets was conducted along with the IAEA Physical Inventory Verification (PIV) inspection at the KEPCO Nuclear Fuel (KNF). The enrichment value of U-235 was calculated based on the total counts of the 185.7 keV photopeak and compared with the reference line, drawn by certified sources. The goal of this study is to experimentally evaluate the system performance of the developed system. In this study, the new portable gamma spectrometry system showed a good linearity (R{sup 2}=1) but overestimated the enrichment values than IAEA inspection device. It could be caused by the stability of the new system since it found, right after this measurement, that the accuracy of the system gradually increases and becomes stable over time. Further steps will optimize the design parameter based on these results and repeat measurement with the same samples under the same environment.

  1. Rigorously testing multialternative decision field theory against random utility models.

    Science.gov (United States)

    Berkowitsch, Nicolas A J; Scheibehenne, Benjamin; Rieskamp, Jörg

    2014-06-01

    Cognitive models of decision making aim to explain the process underlying observed choices. Here, we test a sequential sampling model of decision making, multialternative decision field theory (MDFT; Roe, Busemeyer, & Townsend, 2001), on empirical grounds and compare it against 2 established random utility models of choice: the probit and the logit model. Using a within-subject experimental design, participants in 2 studies repeatedly choose among sets of options (consumer products) described on several attributes. The results of Study 1 showed that all models predicted participants' choices equally well. In Study 2, in which the choice sets were explicitly designed to distinguish the models, MDFT had an advantage in predicting the observed choices. Study 2 further revealed the occurrence of multiple context effects within single participants, indicating an interdependent evaluation of choice options and correlations between different context effects. In sum, the results indicate that sequential sampling models can provide relevant insights into the cognitive process underlying preferential choices and thus can lead to better choice predictions. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  2. FY 1997 evaluation/analysis by site of the data collected in the field test project for photovoltaic power generation for public facilities. 1/3; Kokyo shisetsunadoyo taiyoko hatsuden field test jigyo ni okeru shushu data hyoka kaiseki kaku site betsu (1997 nendo). 1/3

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The data on field tests of the photovoltaic power generation were collected. The items for survey were as follows: horizontal insolation intensity, inclined insolation intensity, effective inclined insolation intensity, average temperature, array electric energy, system electric energy, load electric energy, system supply load, back flow electric energy, interconnected protective movement, disconnection hour, system operation hour, independent operation load, independent supply load, equivalent array operation, equivalent system operation, array output coefficient, system output coefficient, system utilization rate, system charging efficiency, INV effective efficiency, INV load factor, etc. The number of the places for survey is 37 including the following: Hikarigaoka Park of Sakata City, Koiwai Plant of Koiwai Dairy Product Co., Kameoka Ayumi Nursely School, Ichinoseki I-DOME, Okano Park, Kuriyama Park Health Sports Center, Mejiro University, Tokyo Hikarigaoka Sports Facilities, Regional Community Center, Yokohama Tobu Joint Purchase Center, Taemi-so Nursing Care Center for the Elderly, Uemichi School Meal Providing Center, Okayama Prefectural Office, Oita Prefectural Agricultural Research Center, Kanagawa Industrial Technology Research Center Institute, etc. (NEDO)

  3. FY 1999 research report on the evaluation/analysis of the data collected in the field test project for the photovoltaic power system for public facility use; 1999 nendo kokyo shisetsu nadoyo taiyoko hatsuden field test jigyo ni okeru shushu data hyoka kaiseki kenkyu hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    In this research, the photovoltaic power system is experimentally installed at various facilities (public facilities such as public hall, school and museum), and operated on a long term basis under the actual loads. Various kinds of data are collected/analyzed and used as the data useful for the full-scale introduction and spread. The photovoltaic power generation field test project for public facilities using the photovoltaic power system was started in FY 1992 by NEDO. Systems at 116 sites started operation by FY 1996, and in FY 1997 systems were installed at a total of 70 sites. The paper outlined the project and described the results of the collection/analyses of the operational data obtained at 145 sites where systems were installed from FY 1995 to FY 1997. The term of analysis in FY 1999 was made from April 1999 to December 1999, being different from usual, to avoid the Y2K problem on data collecting software, measuring use personal computer, etc. Further, since there are no sites where no systems were newly installed in and after FY 1998, there are no analyses of economical efficiency in and after FY 1999. The paper indicated a list of all the sites with system installation in FY 1995-1997 including the main items. (NEDO)

  4. Research report for fiscal 1998. Evaluation and analysis of the collected data for the field tests on photovoltaic power generation systems for public facilities; 1998 nendo kokyo shisetsu nado yo taiyoko hatsuden field test jigyo ni okeru shushu data hyoka kaiseki kenkyu hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The field tests on photovoltaic power generation systems for public facilities have begun in fiscal 1992 by NEDO. The systems including those under construction are installed in 116 sites. Analyses were given on 75 sites which have been operated up to fiscal 1996. Analyses of the operation characteristics were performed by using performance parameters derived by developing the basic expressions into each configuration element. For the insolation on slanted surface, the range from 3.0 to 4.5 kWh/m{sup 2}/D accounts for 65% of the total insolation. For the equivalent array operation time, the range from 2.5 to 4.0 h/D accounted for 81%. For the equivalent system operation time, the range from 9.0 to 12.0 h/D accounted for 85%. The range for inverter active efficiency from 0.84 to 0.96 accounted for 79%. The inverter load rate was accounted for 88% by 0.20 to 0.35. The output coefficient was accounted for 82% by 0.7 to 1.0 in the array, and 87% by 0.6 to 0.9 in the system. The power generation cost has decreased to 200 yen per kwh in fiscal 1995 from 340 yen per kwh in fiscal 1992, largely contributed by reduced installation cost. (NEDO)

  5. FY 1997 evaluation/analysis by site of the data collected in the field test project for photovoltaic power generation for public facilities. 3/3; Kokyo shisetsunadoyo taiyoko hatsuden field test jigyo ni okeru shushu data hyoka kaiseki kaku site betsu (1997 nendo). 3/3

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-07-01

    The data were collected on field tests of the photovoltaic power generation. The items of measurement are horizontal insolation intensity, inclined insolation intensity, effective inclined insolation intensity, average temperature, array electric energy, system electric energy, load electric energy, system supply load, back flow electric energy, interconnected protective movement, disconnection hour, system operating hour, independent operation load, independent supply load, equivalent array operation, equivalent system operation, array output coefficient, system output coefficient, system utilization rate, system power generation efficiency, INV effective efficiency, INV load factor, etc. The number of places for measurement is 27 including the following: Environmental Science Research Institute, Utatsu-cho Municipal Office, Ginga-gakuin Junior High School, New Energy Business Coop, Nisshin Techno Center, Shikoku Medicom Co., Miyosawa Kinoko-en, Takasaki City Welfare Vocational School, Madama Junior High School, Hitoo Junior High School, Koshien-gakuin Junior/Senior High School, Sansei Technical Research Development Center, Mitsui Greenland, DHI Mach head office/plant, Nabeya Ueno Water Purification Plant, Hoo Senior High School, National Agricultural Resource Research Center, etc. (NEDO)

  6. Preliminary investigation on determination of radionuclide distribution in field tracing test site

    International Nuclear Information System (INIS)

    Tanaka, Tadao; Mukai, Masayuki; Takebe, Shinichi; Guo Zede; Li Shushen; Kamiyama, Hideo.

    1993-12-01

    Field tracing tests for radionuclide migration have been conducted by using 3 H, 60 Co, 85 Sr and 134 Cs, in the natural unsaturated loess zone at field test site of China Institute for Radiation Protection. It is necessary to obtain confidable distribution data of the radionuclides in the test site, in order to evaluate exactly the migration behavior of the radionuclides in situ. An available method to determine the distribution was proposed on the basis of preliminary discussing results on sampling method of soils from the test site and analytical method of radioactivity in the soils. (author)

  7. Field Guide for Evaluating Cottonwood Sites

    Science.gov (United States)

    W.M. Broadfoot

    1960-01-01

    Two field methods have been developed at the Stoneville Research Center for estimating the capability of Midsouth soils to grow eastern cottonwood (Populus deltoides Bartr.). Data for establishing the procedures were collected from 155 plots* at the locations indicated in Figure 1.The methods give site index-that is, tree-growing...

  8. Smart Infrared Inspection System Field Operational Test Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Siekmann, Adam [ORNL; Capps, Gary J [ORNL; Franzese, Oscar [ORNL; Lascurain, Mary Beth [ORNL

    2011-06-01

    The Smart InfraRed Inspection System (SIRIS) is a tool designed to assist inspectors in determining which vehicles passing through the SIRIS system are in need of further inspection by measuring the thermal data from the wheel components. As a vehicle enters the system, infrared cameras on the road measure temperatures of the brakes, tires, and wheel bearings on both wheel ends of commercial motor vehicles (CMVs) in motion. This thermal data is then presented to enforcement personal inside of the inspection station on a user friendly interface. Vehicles that are suspected to have a violation are automatically alerted to the enforcement staff. The main goal of the SIRIS field operational test (FOT) was to collect data to evaluate the performance of the prototype system and determine the viability of such a system being used for commercial motor vehicle enforcement. From March 2010 to September 2010, ORNL facilitated the SIRIS FOT at the Greene County Inspection Station (IS) in Greeneville, Tennessee. During the course of the FOT, 413 CMVs were given a North American Standard (NAS) Level-1 inspection. Of those 413 CMVs, 384 were subjected to a SIRIS screening. A total of 36 (9.38%) of the vehicles were flagged by SIRIS as having one or more thermal issues; with brakes issues making up 33 (91.67%) of those. Of the 36 vehicles flagged as having thermal issues, 31 (86.11%) were found to have a violation and 30 (83.33%) of those vehicles were placed out-of-service (OOS). Overall the enforcement personnel who have used SIRIS for screening purposes have had positive feedback on the potential of SIRIS. With improvements in detection algorithms and stability, the system will be beneficial to the CMV enforcement community and increase overall trooper productivity by accurately identifying a higher percentage of CMVs to be placed OOS with minimal error. No future evaluation of SIRIS has been deemed necessary and specifications for a production system will soon be drafted.

  9. Field study to evaluate radiation doses in dental practices

    International Nuclear Information System (INIS)

    Panzer, W.; Scheurer, C.

    1984-05-01

    An inexpensive and simple test device was developed and used in a field study to evaluate entrance dose, dose to an intra-oral film, filtration and field size under routine conditions in more than 150 dental practices. The test device consists of two films of different speed and a set of 5 thin copper filters for a filter analytical determination of the radiation quality. Dentists voluntarily participating in the study were asked to expose the test device like they usually do when examining a molar tooth. The main result was the evidence of a significant dose reduction compared to the findings of similar studies performed in 1970 and 1976. This reduction is due to a general shift to lower values and a complete disappearance of values above 45 mGy (5 R) which in 1970 were still more than 15%. In the same way the number of facilities showing insufficient filtration or collimation had decreased. Nevertheless, a large spread of dose values could still be observed, ranging from less than 0.45 mGy (50 mR) to more than 26 mGy (3 R), for the entrance dose. The most striking result, however, was that such an important parameter like the speed of the films used at the respective unit turned out to have no impact on the entrance dose. (orig./HP)

  10. DEVELOPMENT AND FIELD EVALUATION OF LIQUID ...

    African Journals Online (AJOL)

    ACSS

    2016-02-26

    Feb 26, 2016 ... growth media and inoculant stabiliser solutions were evaluated. Balanced medium and ... direct human subsistence and is used in several other food products. .... controlled environment (light intensity of 200 µE m-2 second-1, ...

  11. High field, low current operation of engineering test reactors

    International Nuclear Information System (INIS)

    Schwartz, J.; Cohn, D.R.; Bromberg, L.; Williams, J.E.C.

    1987-06-01

    Steady state engineering test reactors with high field, low current operation are investigated and compared to high current, lower field concepts. Illustrative high field ETR parameters are R = 3 m, α ∼ 0.5 m, B ∼ 10 T, β = 2.2% and I = 4 MA. For similar wall loading the fusion power of an illustrative high field, low current concept could be about 50% that of a lower field device like TIBER II. This reduction could lead to a 50% decrease in tritium consumption, resulting in a substantial decrease in operating cost. Furthermore, high field operation could lead to substantially reduced current drive requirements and cost. A reduction in current drive source power on the order of 40 to 50 MW may be attainable relative to a lower field, high current design like TIBER II implying a possible cost savings on the order of $200 M. If current drive is less efficient than assumed, the savings could be even greater. Through larger β/sub p/ and aspect ratio, greater prospects for bootstrap current operation also exist. Further savings would be obtained from the reduced size of the first wall/blanket/shield system. The effects of high fields on magnet costs are very dependent on technological assumptions. Further improvements in the future may lie with advances in superconducting and structural materials

  12. Evaluating 239Pu levels using field detectors

    International Nuclear Information System (INIS)

    Wahl, L.E.; Smith, W.J. II; Martin, B.

    1996-01-01

    At Los Alamos National Laboratory, cleanup was planned at three septic tanks where surface soil in the outfall drainage areas was found to be contaminated with 239 Pu. To meet budget and deadline constraints, a technique was developed that used field instruments to verify 239 Pu soil contamination at levels less than 2.8 Bq g -1 , the established cleanup level. The drainage areas were surveyed using a low-energy gamma probe to identify likely areas of 239 Pu contamination. Between 40 and 135 0.1-min gamma radiation measurements were obtained from each drainage area. From these data, locations were identified for subsequent screening for alpha radioactivity. Soil samples from between 11 and 18 locations at each drainage area were placed in petri dishes, dried, and counted for 10 minutes using an alpha probe. Alpha counts were then related to 239 Pu concentrations using a curve developed from local soils containing known concentrations of 239 Pu. Up to six soil samples from each drainage area, representing a range of alpha radioactivity levels, were sent for laboratory analysis of isotopic plutonium to confirm field measurement results. Analytical and field results correlated well at all but one outfall area. At this area, field measurements predicted more 239 Pu than was measured in the laboratory, indicating the presence of another alpha-emitting radionuclide that might have been missed if only laboratory analyses for plutonium had been used. This technique, which combined a large number of gamma radioactivity measurements, a moderate number of alpha radioactivity measurements, and a few isotopic plutonium measurements, allowed quick and inexpensive comparison of 239 Pu with the cleanup level

  13. Rheological Method for Alpha Test Evaluation of Developing Superplasticizers’ Performance: Channel Flow Test

    Directory of Open Access Journals (Sweden)

    Jae Hong Kim

    2017-01-01

    Full Text Available Advance in high-range water-reducing admixture revolutionizes the workability and constructability of conventional vibrated concrete as well as self-consolidating concrete. Its need from construction fields has increased, and consequently a variety of new-type polycarboxylates, base polymers for the admixture, are being formulated in these days. Synthesizing new polymers needs a quick, but reliable, test to evaluate its performance on concrete. The test is also asked for selecting the best applicable brand of them before a test concrete will be mixed. This paper proposes a “channel flow test” and its usage for the purpose. The proposed procedure for the test includes the mix proportion of a test mortar, the test method, and rheological interpretation of the test results.

  14. Physicians' subjectivity in evaluating oxytocin challenge tests.

    Science.gov (United States)

    Peck, T M

    1980-07-01

    Five physicians subspecializing in maternal-fetal medicine individually evaluated 50 oxytocin challenge tests (OCTs), of which 33 were originally read as positive. There was considerable disagreement among the study physicians (SPs) such that 2 SPs would agree, on the average, only 52% of the time on any one OCT. The SPs were also asked to evaluate fetal heart rate (FHR) reactivity patterns, if present. Again, there was great disagreement. When the majority (3 of 5 or more) of SPs agreed on the OCT result and/or reactivity, there was reasonable correlation with neonatal outcome, indicating the validity of the physiologic premise of the test. In particular, the presence or absence of FHR accelerations with fetal motion, regardless of the OCT reading, correlated extremely well with eventual neonatal outcome. This indicates that the most significant variable in antepartum FHR monitoring is the FHR acceleration pattern.

  15. A Preliminary Field Test of an Employee Work Passion Model

    Science.gov (United States)

    Zigarmi, Drea; Nimon, Kim; Houson, Dobie; Witt, David; Diehl, Jim

    2011-01-01

    Four dimensions of a process model for the formulation of employee work passion, derived from Zigarmi, Nimon, Houson, Witt, and Diehl (2009), were tested in a field setting. A total of 447 employees completed questionnaires that assessed the internal elements of the model in a corporate work environment. Data from the measurements of work affect,…

  16. Couplex1 test case nuclear - Waste disposal far field simulation

    International Nuclear Information System (INIS)

    2001-01-01

    This first COUPLEX test case is to compute a simplified Far Field model used in nuclear waste management simulation. From the mathematical point of view the problem is of convection diffusion type but the parameters are highly varying from one layer to another. Another particularity is the very concentrated nature of the source, both in space and in time. (author)

  17. Rock sealing - large scale field test and accessory investigations

    International Nuclear Information System (INIS)

    Pusch, R.

    1988-03-01

    The experience from the pilot field test and the basic knowledge extracted from the lab experiments have formed the basis of the planning of a Large Scale Field Test. The intention is to find out how the 'instrument of rock sealing' can be applied to a number of practical cases, where cutting-off and redirection of groundwater flow in repositories are called for. Five field subtests, which are integrated mutually or with other Stripa projects (3D), are proposed. One of them concerns 'near-field' sealing, i.e. sealing of tunnel floors hosting deposition holes, while two involve sealing of 'disturbed' rock around tunnels. The fourth concerns sealing of a natural fracture zone in the 3D area, and this latter test has the expected spin-off effect of obtaining additional information on the general flow pattern around the northeastern wing of the 3D cross. The fifth test is an option of sealing structures in the Validation Drift. The longevity of major grout types is focussed on as the most important part of the 'Accessory Investigations', and detailed plans have been worked out for that purpose. It is foreseen that the continuation of the project, as outlined in this report, will yield suitable methods and grouts for effective and long-lasting sealing of rock for use at stategic points in repositories. (author)

  18. Design and field tests of a modified small mammallivetrap

    African Journals Online (AJOL)

    -vinyl-chloride) and metal small mammal live-trap has been developed and subjected to field tests. The PVC traps captured greater numbers of very small rodents and shrews but fewer large rodents than did hardboard ones. s. Afr. J. Zool.

  19. Field test of a new Australian method of rangeland monitoring

    Science.gov (United States)

    Suzanne Mayne; Neil West

    2001-01-01

    Managers need more efficient means of monitoring changes on the lands they manage. Accordingly, a new Australian approach was field tested and compared to the Daubenmire method of assessing plant cover, litter, and bare soil. The study area was a 2 mile wide by 30.15 mile long strip, mostly covered by salt desert shrub ecosystem types, centered along the SE boundary of...

  20. Heat pumps in field test; Waermepumpen im Feldtest

    Energy Technology Data Exchange (ETDEWEB)

    Becker, R. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany); Miara, M.; Russ, C.

    2007-09-15

    The Fraunhofer ISE has launched two field tests of newly installed heat pumps in 2006. Both deal with the measurement of a high number of heat pump units under real conditions in small houses. Values of volume flows, temperatures, heat quantity and electricity consumption are collected and daily saved and analysed at the Fraunhofer ISE. (orig.)

  1. Simple and rapid field tests for brucellosis in livestock

    NARCIS (Netherlands)

    Abdoel, Theresia; Dias, Isabel Travassos; Cardoso, Regina; Smits, Henk L.

    2008-01-01

    Four simple and rapid field tests for the serodiagnosis of brucellosis in cattle, goat, sheep and swine were developed. The performance of the assays was investigated using serum samples collected in Portugal from animals originating from herds with a defined sanitary status with respect to the

  2. A field performance evaluation of drip emitters: pressure versus ...

    African Journals Online (AJOL)

    Field evaluation of irrigation systems (drip) can form a basis for decision making as to whether the irrigation system needs rehabilitation, overhaul or even dismantling if found to be very uneconomical. A comprehensive field evaluation of irrigation systems involves determining the overall efficiency of the system, for example, ...

  3. The Advanced Test Reactor Strategic Evaluation Program

    International Nuclear Information System (INIS)

    Buescher, B.J.

    1990-01-01

    A systematic evaluation of safety, environmental, and operational issues has been initiated at the Advanced Test Reactor (ATR). This program, the Strategic Evaluation Program (STEP), provides an integrated review of safety and operational issues against the standards applied to licensed commercial facilities. In the review of safety issues, 18 deviations were identified which required prompt attention. Resolution of these items has been accelerated in the program. An integrated living schedule is being developed to address the remaining findings. A risk evaluation is being performed on the proposed corrective actions and these actions will then be formally ranked in order of priority based on considerations of safety and operational significance. Once the final ranking is completed, an integrated schedule will be developed, which will include considerations of availability of funding and operating schedule. 3 refs., 2 figs

  4. REARING TOMATO WHITEFLY AND FIELD EVALUATION OF ...

    African Journals Online (AJOL)

    ACSS

    2015-05-27

    May 27, 2015 ... important agricultural and ornamental crops in all agro-ecological regions in the world. This study evaluated the ... conidia: (a) modified conidia (conidia with improved ecological competence), and (b) unmodified conidia of the three isolates were subjected ..... control of cotton spider mites. There was a wide ...

  5. Sequential accelerated tests: Improving the correlation of accelerated tests to module performance in the field

    Science.gov (United States)

    Felder, Thomas; Gambogi, William; Stika, Katherine; Yu, Bao-Ling; Bradley, Alex; Hu, Hongjie; Garreau-Iles, Lucie; Trout, T. John

    2016-09-01

    DuPont has been working steadily to develop accelerated backsheet tests that correlate with solar panels observations in the field. This report updates efforts in sequential testing. Single exposure tests are more commonly used and can be completed more quickly, and certain tests provide helpful predictions of certain backsheet failure modes. DuPont recommendations for single exposure tests are based on 25-year exposure levels for UV and humidity/temperature, and form a good basis for sequential test development. We recommend a sequential exposure of damp heat followed by UV then repetitions of thermal cycling and UVA. This sequence preserves 25-year exposure levels for humidity/temperature and UV, and correlates well with a large body of field observations. Measurements can be taken at intervals in the test, although the full test runs 10 months. A second, shorter sequential test based on damp heat and thermal cycling tests mechanical durability and correlates with loss of mechanical properties seen in the field. Ongoing work is directed toward shorter sequential tests that preserve good correlation to field data.

  6. Test results of BM109 magnet field stability during ramping

    International Nuclear Information System (INIS)

    Kristalinski, A.

    1992-12-01

    This report presents results of the measured lag between the current ramp and the following magnetic field rise in BM109 magnets. The purpose of these tests is to choose identical ramping programs for PC4AN1, PC4AN2 and PC4AN3 magnets. The lag occurs due to the large eddy currents in the magnets' solid iron cores. The experiment requires a magnetic field stability of 0.1% during beam presence. Using existing equipment and a program slope of 100 Amp/sec starting at Tl yields fields within the 0.05% of set value. Add to this 0.05% for P.S. regulation to meet the required field stability of 0.1%. This program yields annual savings of $200,000 (assuming 100% usage) . Additional savings can be made by using faster slopes, but this requires additional controls

  7. Potential of the test particle in the magnetic field. I

    International Nuclear Information System (INIS)

    Sestak, B.

    1980-01-01

    The problem of the test particle potential in an external homogeneous magnetic field is solved in an unmagnetized plasma. It is shown that for the case when the parallel velocity component of the test particle is greater than the thermal velocity of the background particles, the potential is of a Coulomb character while for the case where the parallel velocity component is less than the thermal velocity the potential is of a Debye character. The Larmor radius of the test particle appears as an additional parameter in these potentials. (author)

  8. Test field for airborne laser scanning in Finland

    Science.gov (United States)

    Ahokas, E.; Kaartinen, H.; Kukko, A.; Litkey, P.

    2014-11-01

    Airborne laser scanning (ALS) is a widely spread operational measurement tool for obtaining 3D coordinates of the ground surface. There is a need for calibrating the ALS system and a test field for ALS was established at the end of 2013. The test field is situated in the city of Lahti, about 100 km to the north of Helsinki. The size of the area is approximately 3.5 km × 3.2 km. Reference data was collected with a mobile laser scanning (MLS) system assembled on a car roof. Some streets were measured both ways and most of them in one driving direction only. The MLS system of the Finnish Geodetic Institute (FGI) consists of a navigation system (NovAtel SPAN GNSS-IMU) and a laser scanner (FARO Focus3D 120). In addition to the MLS measurements more than 800 reference points were measured using a Trimble R8 VRS-GNSS system. Reference points are along the streets, on parking lots, and white pedestrian crossing line corners which can be used as reference targets. The National Land Survey of Finland has already used this test field this spring for calibrating their Leica ALS-70 scanner. Especially it was easier to determine the encoder scale factor parameter using this test field. Accuracy analysis of the MLS points showed that the point height RMSE is 2.8 cm and standard deviation is 2.6 cm. Our purpose is to measure both more MLS data and more reference points in the test field area to get a better spatial coverage. Calibration flight heights are planned to be 1000 m and 2500 m above ground level. A cross pattern, southwest-northeast and northwest-southeast, will be flown both in opposite directions.

  9. Deep Borehole Field Test Research Activities at LBNL

    Energy Technology Data Exchange (ETDEWEB)

    Dobson, Patrick [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Tsang, Chin-Fu [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Kneafsey, Timothy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Borglin, Sharon [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Piceno, Yvette [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Andersen, Gary [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Nakagawa, Seiji [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Nihei, Kurt [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rutqvist, Jonny [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Doughty, Christine [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Reagan, Matthew [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-08-19

    The goal of the U.S. Department of Energy Used Fuel Disposition’s (UFD) Deep Borehole Field Test is to drill two 5 km large-diameter boreholes: a characterization borehole with a bottom-hole diameter of 8.5 inches and a field test borehole with a bottom-hole diameter of 17 inches. These boreholes will be used to demonstrate the ability to drill such holes in crystalline rocks, effectively characterize the bedrock repository system using geophysical, geochemical, and hydrological techniques, and emplace and retrieve test waste packages. These studies will be used to test the deep borehole disposal concept, which requires a hydrologically isolated environment characterized by low permeability, stable fluid density, reducing fluid chemistry conditions, and an effective borehole seal. During FY16, Lawrence Berkeley National Laboratory scientists conducted a number of research studies to support the UFD Deep Borehole Field Test effort. This work included providing supporting data for the Los Alamos National Laboratory geologic framework model for the proposed deep borehole site, conducting an analog study using an extensive suite of geoscience data and samples from a deep (2.5 km) research borehole in Sweden, conducting laboratory experiments and coupled process modeling related to borehole seals, and developing a suite of potential techniques that could be applied to the characterization and monitoring of the deep borehole environment. The results of these studies are presented in this report.

  10. Deep Borehole Field Test Research Activities at LBNL

    International Nuclear Information System (INIS)

    Dobson, Patrick; Tsang, Chin-Fu; Kneafsey, Timothy; Borglin, Sharon; Piceno, Yvette; Andersen, Gary; Nakagawa, Seiji; Nihei, Kurt; Rutqvist, Jonny; Doughty, Christine; Reagan, Matthew

    2016-01-01

    The goal of the U.S. Department of Energy Used Fuel Disposition's (UFD) Deep Borehole Field Test is to drill two 5 km large-diameter boreholes: a characterization borehole with a bottom-hole diameter of 8.5 inches and a field test borehole with a bottom-hole diameter of 17 inches. These boreholes will be used to demonstrate the ability to drill such holes in crystalline rocks, effectively characterize the bedrock repository system using geophysical, geochemical, and hydrological techniques, and emplace and retrieve test waste packages. These studies will be used to test the deep borehole disposal concept, which requires a hydrologically isolated environment characterized by low permeability, stable fluid density, reducing fluid chemistry conditions, and an effective borehole seal. During FY16, Lawrence Berkeley National Laboratory scientists conducted a number of research studies to support the UFD Deep Borehole Field Test effort. This work included providing supporting data for the Los Alamos National Laboratory geologic framework model for the proposed deep borehole site, conducting an analog study using an extensive suite of geoscience data and samples from a deep (2.5 km) research borehole in Sweden, conducting laboratory experiments and coupled process modeling related to borehole seals, and developing a suite of potential techniques that could be applied to the characterization and monitoring of the deep borehole environment. The results of these studies are presented in this report.

  11. R20 Programme: Field testing of grouting materials

    International Nuclear Information System (INIS)

    Ranta-Korpi, R.; Karttunen, P.; Sievaenen, U.

    2008-02-01

    In the year 2004 Finnish nuclear waste management organisation Posiva Oy started to construct an underground rock characterisation facility in Olkiluoto, Eurajoki, Western Finland. The ONKALO was planned to be a final disposal of spent nuclear fuel in Finland. This facility is going to be finished in the end of the year 2010. In ONKALO it is important to grout the water conductive structures to minimize the leakage of the inflowing groundwater in order to keep the geohydrogical environment unchanged and the repository conditions safe. Before the construction began the development of the grouts suitable for this demanding environment was started. Especially pH, the penetration ability and rheology have been the matter of interest. One target for the grout has been that the pH is relatively low. These grouts have different properties than the normal grouts. Several laboratory and field tests have been done for low pH grouts. The suitable recipies are studied in laboratory and the properties are verified in field. This work concerns the field testing of several low pH grout recipies. The different W/DM -ratios and SPL contents were studied. Besides the customary test methods, two new measurement methods were taken into use: the sand column test for measuring the penetration ability and the stick test for determining the plastic viscosity and yield value. The relationships between different properties, the properties as a function of the time and the effect of the (orig.)

  12. Initial field testing definition of subsurface sealing and backfilling tests in unsaturated tuff

    International Nuclear Information System (INIS)

    Fernandez, J.A.; Case, J.B.; Tyburski, J.R.

    1993-05-01

    This report contains an initial definition of the field tests proposed for the Yucca Mountain Project repository sealing program. The tests are intended to resolve various performance and emplacement concerns. Examples of concerns to be addressed include achieving selected hydrologic and structural requirements for seals, removing portions of the shaft liner, excavating keyways, emplacing cementitious and earthen seals, reducing the impact of fines on the hydraulic conductivity of fractures, efficient grouting of fracture zones, sealing of exploratory boreholes, and controlling the flow of water by using engineered designs. Ten discrete tests are proposed to address these and other concerns. These tests are divided into two groups: Seal component tests and performance confirmation tests. The seal component tests are thorough small-scale in situ tests, the intermediate-scale borehole seal tests, the fracture grouting tests, the surface backfill tests, and the grouted rock mass tests. The seal system tests are the seepage control tests, the backfill tests, the bulkhead test in the Calico Hills unit, the large-scale shaft seal and shaft fill tests, and the remote borehole sealing tests. The tests are proposed to be performed in six discrete areas, including welded and non-welded environments, primarily located outside the potential repository area. The final selection of sealing tests will depend on the nature of the geologic and hydrologic conditions encountered during the development of the Exploratory Studies Facility and detailed numerical analyses. Tests are likely to be performed both before and after License Application

  13. Evaluation methodologies for security testing biometric systems beyond technological evaluation

    OpenAIRE

    Fernández Saavedra, María Belén

    2013-01-01

    The main objective of this PhD Thesis is the specification of formal evaluation methodologies for testing the security level achieved by biometric systems when these are working under specific contour conditions. This analysis is conducted through the calculation of the basic technical biometric system performance and its possible variations. To that end, the next two relevant contributions have been developed. The first contribution is the definition of two independent biometric performance ...

  14. Acceptance test report: Field test of mixer pump for 241-AN-107 caustic addition project

    International Nuclear Information System (INIS)

    Leshikar, G.A.

    1997-01-01

    The field acceptance test of a 75 HP mixer pump (Hazleton serial number N-20801) installed in Tank 241-AN-107 was conducted from October 1995 thru February 1996. The objectives defined in the acceptance test were successfully met, with two exceptions recorded. The acceptance test encompassed field verification of mixer pump turntable rotation set-up and operation, verification that the pump instrumentation functions within established limits, facilitation of baseline data collection from the mixer pump mounted ultrasonic instrumentation, verification of mixer pump water flush system operation and validation of a procedure for its operation, and several brief test runs (bump) of the mixer pump

  15. Evaluation of clinical methods for peroneal muscle testing.

    Science.gov (United States)

    Sarig-Bahat, Hilla; Krasovsky, Andrei; Sprecher, Elliot

    2013-03-01

    Manual muscle testing of the peroneal muscles is well accepted as a testing method in musculoskeletal physiotherapy for the assessment of the foot and ankle. The peroneus longus and brevis are primary evertors and secondary plantar flexors of the ankle joint. However, some international textbooks describe them as dorsi flexors, when instructing peroneal muscle testing. The identified variability raised a question whether these educational texts are reflected in the clinical field. The purposes of this study were to investigate what are the methods commonly used in the clinical field for peroneal muscle testing and to evaluate their compatibility with functional anatomy. A cross-sectional study was conducted, using an electronic questionnaire sent to 143 Israeli physiotherapists in the musculoskeletal field. The survey questioned on the anatomical location of manual resistance and the combination of motions resisted. Ninety-seven responses were received. The majority (69%) of respondents related correctly to the peronei as evertors, but asserted that resistance should be located over the dorsal aspect of the fifth metatarsus, thereby disregarding the peroneus longus. Moreover, 38% of the respondents described the peronei as dorsi flexors, rather than plantar flexors. Only 2% selected the correct method of resisting plantarflexion and eversion at the base of the first metatarsus. We consider this technique to be the most compatible with the anatomy of the peroneus longus and brevis. The Fisher-Freeman-Halton test indicated that there was a significant relationship between responses on the questions (P = 0.0253, 95% CI 0.0249-0.0257), thus justifying further correspondence analysis. The correspondence analysis found no clustering of the answers that were compatible with anatomical evidence and were applied in the correct technique, but did demonstrate a common error, resisting dorsiflexion rather than plantarflexion, which was in agreement with the described

  16. Large Field Photogrammetry Techniques in Aircraft and Spacecraft Impact Testing

    Science.gov (United States)

    Littell, Justin D.

    2010-01-01

    The Landing and Impact Research Facility (LandIR) at NASA Langley Research Center is a 240 ft. high A-frame structure which is used for full-scale crash testing of aircraft and rotorcraft vehicles. Because the LandIR provides a unique capability to introduce impact velocities in the forward and vertical directions, it is also serving as the facility for landing tests on full-scale and sub-scale Orion spacecraft mass simulators. Recently, a three-dimensional photogrammetry system was acquired to assist with the gathering of vehicle flight data before, throughout and after the impact. This data provides the basis for the post-test analysis and data reduction. Experimental setups for pendulum swing tests on vehicles having both forward and vertical velocities can extend to 50 x 50 x 50 foot cubes, while weather, vehicle geometry, and other constraints make each experimental setup unique to each test. This paper will discuss the specific calibration techniques for large fields of views, camera and lens selection, data processing, as well as best practice techniques learned from using the large field of view photogrammetry on a multitude of crash and landing test scenarios unique to the LandIR.

  17. Pretest Calculations of Temperature Changes for Field Thermal Conductivity Tests

    International Nuclear Information System (INIS)

    N.S. Brodsky

    2002-01-01

    A large volume fraction of the potential monitored geologic repository at Yucca Mountain may reside in the Tptpll (Tertiary, Paintbrush Group, Topopah Spring Tuff, crystal poor, lower lithophysal) lithostratigraphic unit. This unit is characterized by voids, or lithophysae, which range in size from centimeters to meters. A series of thermal conductivity field tests are planned in the Enhanced Characterization of the Repository Block (ECRB) Cross Drift. The objective of the pretest calculation described in this document is to predict changes in temperatures in the surrounding rock for these tests for a given heater power and a set of thermal transport properties. The calculation can be extended, as described in this document, to obtain thermal conductivity, thermal capacitance (density x heat capacity, J · m -3 · K -1 ), and thermal diffusivity from the field data. The work has been conducted under the ''Technical Work Plan For: Testing and Monitoring'' (BSC 2001). One of the outcomes of this analysis is to determine the initial output of the heater. This heater output must be sufficiently high that it will provide results in a reasonably short period of time (within several weeks or a month) and be sufficiently high that the heat increase is detectable by the instruments employed in the test. The test will be conducted in stages and heater output will be step increased as the test progresses. If the initial temperature is set too high, the experiment will not have as many steps and thus fewer thermal conductivity data points will result

  18. [New visual field testing possibilities (a preliminary report)].

    Science.gov (United States)

    Erichev, V P; Ermolaev, A P; Antonov, A A; Grigoryan, G L; Kosova, D V

    2018-01-01

    There are currently no portable mobile perimeters that allow visual field testing outside ophthalmologist's examination rooms. To develop a mobile perimetry technique based on use of a virtual reality headset (VR). The study involved 26 patients (30 eyes) with II-III stage primary open-angle glaucoma (POAG) with compensated IOP. Perimetry was performed for each patient twice - on Humphrey analyzer (test 30-2, 76 points) and employing similar strategy on a perimeter integrated into VR headset (Total Vision, Russia). Visual field testing was performed with an interval from 1 hour to 3 days. The results were comparatively analyzed. Patients tolerated the examination well. Comparative analysis of preliminary perimetry results obtained with both methods showed high degree of identity, so the results were concluded to be comparable. By visually isolating the wearer, VR headset achieves elimination of distractions and stable light conditions for visual field testing. The headset-perimeter is compact, mobile, easily transportable, can be used in the work of visiting medical teams and for examination at home.

  19. AFFTC Instruction 99-1, Test and Evaluation Test Plans

    National Research Council Canada - National Science Library

    Crane, Roger

    2002-01-01

    .... Test Information Sheets (TISs) are actually appendices to test plans and contain sufficient information for use by a flight test engineer to develop flight test cards and for management to discern the overall technical approach being taken...

  20. Evaluation of Rice Resistance to Southern Rice Black-Streaked Dwarf Virus and Rice Ragged Stunt Virus through Combined Field Tests, Quantitative Real-Time PCR, and Proteome Analysis.

    Science.gov (United States)

    Wang, Zhenchao; Yu, Lu; Jin, Linhong; Wang, Wenli; Zhao, Qi; Ran, Longlu; Li, Xiangyang; Chen, Zhuo; Guo, Rong; Wei, Yongtian; Yang, Zhongcheng; Liu, Enlong; Hu, Deyu; Song, Baoan

    2017-02-22

    Diseases caused by southern rice black-streaked dwarf virus (SRBSDV) and rice ragged stunt virus (RRSV) considerably decrease grain yield. Therefore, determining rice cultivars with high resistance to SRBSDV and RRSV is necessary. In this study, rice cultivars with high resistance to SRBSDV and RRSV were evaluated through field trials in Shidian and Mangshi county, Yunnan province, China. SYBR Green I-based quantitative real-time polymerase chain reaction (qRT-PCR) analysis was used to quantitatively detect virus gene expression levels in different rice varieties. The following parameters were applied to evaluate rice resistance: acre yield (A.Y.), incidence of infected plants (I.I.P.), virus load (V.L.), disease index (D.I.), and insect quantity (I.Q.) per 100 clusters. Zhongzheyou1 (Z1) and Liangyou2186 (L2186) were considered the most suitable varieties with integrated higher A.Y., lower I.I.P., V.L., D.I. and I.Q. In order to investigate the mechanism of rice resistance, comparative label-free shotgun liquid chromatography tandem-mass spectrometry (LC-MS/MS) proteomic approaches were applied to comprehensively describe the proteomics of rice varieties' SRBSDV tolerance. Systemic acquired resistance (SAR)-related proteins in Z1 and L2186 may result in the superior resistance of these varieties compared with Fengyouxiangzhan (FYXZ).

  1. Validation of a field test for the non-invasive determination of badminton specific aerobic performance

    Science.gov (United States)

    Wonisch, M; Hofmann, P; Schwaberger, G; von Duvillard, S P; Klein, W

    2003-01-01

    Aim: To develop a badminton specific test to determine on court aerobic and anaerobic performance. Method: The test was evaluated by using a lactate steady state test. Seventeen male competitive badminton players (mean (SD) age 26 (8) years, weight 74 (10) kg, height 179 (7) cm) performed an incremental field test on the badminton court to assess the heart rate turn point (HRTP) and the individual physical working capacity (PWCi) at 90% of measured maximal heart rate (HRmax). All subjects performed a 20 minute steady state test at a workload just below the PWCi. Results: Significant correlations (pbadminton is possible without HRTP determination. PMID:12663351

  2. Medium and Heavy Duty Vehicle Field Evaluations (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Walkowicz, K.

    2014-06-01

    This presentation discusses field evaluations of medium- and heavy-duty vehicles performed by NREL. The project provides medium-duty (MD) and heavy-duty (HD) test results, aggregated data, and detailed analysis, including 3rd party unbiased data (data that would not normally be shared by industry in an aggregated and detailed manner). Over 5.6 million miles of advanced technology MD and HD truck data have been collected, documented, and analyzed on over 240 different vehicles since 2002. Data, analysis, and reports are shared within DOE, national laboratory partners, and industry for R&D planning and strategy. The results help guide R&D for new technology development, help define intelligent usage of newly developed technology, and help fleets/users understand all aspects of advanced technology.

  3. Test, measurement and evaluation with the mine boot test and evaluation system

    CSIR Research Space (South Africa)

    Ramaloko, PM

    2014-09-01

    Full Text Available Protective footwear that mitigates the shock transferred to the victim’s leg during an antipersonnel landmine blast need to be evaluated to verify their protection levels. The Mine Boot Test and Evaluation System which include a surrogate lower leg...

  4. Evaluation of Mycology Laboratory Proficiency Testing

    Science.gov (United States)

    Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max

    1999-01-01

    Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient testing. This study addresses this issue by evaluating medical mycology OPT and comparing its fungal specimen identification error rates to those obtained in a covert (blinded) proficiency testing (CPT) program. Identifications from 188 laboratories participating in the New York State mycology OPT from 1982 to 1994 were compared with the identifications of the same fungi recovered from patient specimens in 1989 and 1994 as part of the routine procedures of 88 of these laboratories. The consistency in the identification of OPT specimens was sufficient to make accurate predictions of OPT error rates. However, while the error rates in OPT and CPT were similar for Candida albicans, significantly higher error rates were found in CPT for Candida tropicalis, Candida glabrata, and other common pathogenic fungi. These differences may, in part, be due to OPT’s use of ideal organism representatives cultured under optimum growth conditions. This difference, as well as the organism-dependent error rate differences, reflects the limitations of OPT as a means of assessing the quality of routine laboratory performance in medical mycology. PMID:10364601

  5. Thermionic system evaluated test (TSET) facility description

    Science.gov (United States)

    Fairchild, Jerry F.; Koonmen, James P.; Thome, Frank V.

    1992-01-01

    A consortium of US agencies are involved in the Thermionic System Evaluation Test (TSET) which is being supported by the Strategic Defense Initiative Organization (SDIO). The project is a ground test of an unfueled Soviet TOPAZ-II in-core thermionic space reactor powered by electrical heat. It is part of the United States' national thermionic space nuclear power program. It will be tested in Albuquerque, New Mexico at the New Mexico Engineering Research Institute complex by the Phillips Laboratoty, Sandia National Laboratories, Los Alamos National Laboratory, and the University of New Mexico. One of TSET's many objectives is to demonstrate that the US can operate and test a complete space nuclear power system, in the electrical heater configuration, at a low cost. Great efforts have been made to help reduce facility costs during the first phase of this project. These costs include structural, mechanical, and electrical modifications to the existing facility as well as the installation of additional emergency systems to mitigate the effects of utility power losses and alkali metal fires.

  6. Exercise testing in Warmblood sport horses under field conditions.

    Science.gov (United States)

    Munsters, Carolien C B M; van Iwaarden, Alexandra; van Weeren, René; Sloet van Oldruitenborgh-Oosterbaan, Marianne M

    2014-10-01

    Regular exercise testing in Warmblood sport horses may, as in racing, potentially help to characterise fitness indices in different disciplines and at various competition levels and assist in understanding when a horse is 'fit to compete'. In this review an overview is given of the current state of the art of exercise testing in the Olympic disciplines of eventing, show jumping and dressage, and areas for further development are defined. In event horses, a simple four-step incremental exercise test measuring heart rate (HR), lactate concentration (LA) and velocity (V) is most often used. In dressage and riding horses, a wide variety of exercise tests have been developed, including incremental exercise tests, indoor riding tests and lunging tests. In show jumping, the use of a five-step incremental exercise test and exercise tests evaluating technical skills and fatigue of the horse has been reported. The velocity at a plasma LA of 4 mmol/L (VLA4) and HR recovery during submaximal exercise intensity have been shown to be the best parameters in event horses for predicting performance and impending injuries. In riding horses, the fitness level of horses is also an important determinant of injuries. Implementation of regular exercise testing and monitoring of training sessions may have important added value in the assessment of performance ability and potential future injuries in Warmblood sport horses. However, there is an urgent need to standardise methodologies and outcome parameters in order to make results comparable. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Field testing of near-real-time materials accountancy at the PNC-Tokai reprocessing plant

    International Nuclear Information System (INIS)

    Miura, N.; Masui, J.; Komatsu, H.; Todokoro, A.; Iwanaga, M.; Kusano, T.; Komori, Y.; Lovett, J.

    1987-01-01

    In 1985 a decision was taken to conduct a joint PNC-IAEA field test under the JASPAS support programme during the 85-2 campaign. The purpose of the field test, as with the earlier internal field test work performed by PNC, was to demonstrate the practicality of near-real-time accountancy using the ten day detection time model and to collect meaningful real data (as contrasted with model data) to evaluate the potential effectiveness of near-real-time accountancy in IAEA safeguards. This report summarizes, discusses and evaluates the data collected, not only during the 85-2 joint field test, but also during all previous campaigns. Chapter 2 gives a description of near-real-time accountancy as it has developed at PNC-Tokai, although the reader is referred to (3) for a more complete description. Chapter 3 reviews the procedures followed in the collection of the data, in particular during the 85-2 campaign joint field test. Chapter 4 presents the ''raw'' data collected. Chapter 5 then presents what is here termed an ''Engineering Evaluation'' of the data. The discussion in Chapter 5 is directed at a technical understanding of the data and at the resolution of a few identified problems which otherwise limit the usefulness of the data, not at a mathematical evaluation of possible diversion detection. The discussion accordingly is largely qualitative and subjective. Chapter 5 also presents a brief analysis of the data in terms of the ''running book inventory'' concept which some have suggested would be simpler and at least adequately effective. Chapter 6 discusses a number of important questions regarding work load, effect of unmeasured inventory fluctuation, data requirement, verification and authentication, and effectiveness of NRTA. Finally, Chapter 7 summarizes the conclusions which can be drawn from the field test work

  8. Field Test Kit for Gun Residue Detection; TOPICAL

    International Nuclear Information System (INIS)

    WALKER, PAMELA K.; RODACY, PHILIP J.

    2002-01-01

    One of the major needs of the law enforcement field is a product that quickly, accurately, and inexpensively identifies whether a person has recently fired a gun--even if the suspect has attempted to wash the traces of gunpowder off. The Field Test Kit for Gunshot Residue Identification based on Sandia National Laboratories technology works with a wide variety of handguns and other weaponry using gunpowder. There are several organic chemicals in small arms propellants such as nitrocellulose, nitroglycerine, dinitrotoluene, and nitrites left behind after the firing of a gun that result from the incomplete combustion of the gunpowder. Sandia has developed a colorimetric shooter identification kit for in situ detection of gunshot residue (GSR) from a suspect. The test kit is the first of its kind and is small, inexpensive, and easily transported by individual law enforcement personnel requiring minimal training for effective use. It will provide immediate information identifying gunshot residue

  9. Field test of wake steering at an offshore wind farm

    Directory of Open Access Journals (Sweden)

    P. Fleming

    2017-05-01

    Full Text Available In this paper, a field test of wake-steering control is presented. The field test is the result of a collaboration between the National Renewable Energy Laboratory (NREL and Envision Energy, a smart energy management company and turbine manufacturer. In the campaign, an array of turbines within an operating commercial offshore wind farm in China have the normal yaw controller modified to implement wake steering according to a yaw control strategy. The strategy was designed using NREL wind farm models, including a computational fluid dynamics model, Simulator fOr Wind Farm Applications (SOWFA, for understanding wake dynamics and an engineering model, FLOw Redirection and Induction in Steady State (FLORIS, for yaw control optimization. Results indicate that, within the certainty afforded by the data, the wake-steering controller was successful in increasing power capture, by amounts similar to those predicted from the models.

  10. Do Persistence and Passion Matter: Evidence from the Educational Testing Service Major Field Test in Business

    Science.gov (United States)

    Ketcham, David; Nigro, Peter; Roberto, Michael

    2018-01-01

    The authors examined the determinants of success on the Educational Testing Service Major Field Test in Business. The authors find that gender, SAT performance, and concentration are significant predictors of performance. Additionally, they derive proxies for student passion and persistence, and find that the greater the student's passion for…

  11. Scientific investigation plan for initial engineered barrier system field tests

    International Nuclear Information System (INIS)

    Wunan Lin.

    1993-02-01

    The purpose of this Scientific Investigation Plan (SIP) is to describe tests known as Initial Engineered Barrier System Field Tests (IEBSFT) and identified by Work Breakdown Structure as WBS 1.2.2.2.4. The IEBSFT are precursors to the Engineered Barrier System Field Test (EBSFT), WBS 1.2.2.2.4, to be conducted in the Exploratory Study Facility (ESF) at Yucca Mountain. The EBSFT and IEBSFT are designed to provide information on the interaction between waste packages (simulated by heated containers) and the surrounding rock mass, its vadose water, and infiltrated water. Heater assemblies will be installed in drifts or boreholes openings and heated to measure moisture movement during heat-up and subsequent cool-down of the rock mass. In some of the tests, infiltration of water into the heated rock mass will be studied. Throughout the heating and cooling cycle, instruments installed in the rock will monitor such parameters as temperature, moisture content, concentration of some chemical species, and stress and strain. Rock permeability measurements, rock and fluid (water and gas) sampling, and fracture pattern measurements will also be made before and after the test

  12. Field Test of Driven Pile Group under Lateral Loading

    Science.gov (United States)

    Gorska, Karolina; Rybak, Jaroslaw; Wyjadlowski, Marek

    2017-12-01

    All the geotechnical works need to be tested because the diversity of soil parameters is much higher than in other fields of construction. Horizontal load tests are necessary to determine the lateral capacity of driven piles subject to lateral load. Various load tests were carried out altogether on the test field in Kutno (Poland). While selecting the piles for load tests, different load combinations were taken into account. The piles with diverse length were chosen, on the basis of the previous tests of their length and integrity. The subsoil around the piles consisted of mineral soils: clays and medium compacted sands with the density index ID>0.50. The pile heads were free. The points of support of the “base” to which the dial gauges (displacement sensors) were fastened were located at the distance of 0.7 m from the side surface of the pile loaded laterally. In order to assure the independence of measurement, additional control (verifying) geodetic survey of the displacement of the piles subject to the load tests was carried out (by means of the alignment method). The trial load was imposed in stages by means of a hydraulic jack. The oil pressure in the actuator was corrected by means of a manual pump in order to ensure the constant value of the load in the on-going process of the displacement of the pile under test. On the basis of the obtained results it is possible to verify the numerical simulations of the behaviour of piles loaded by a lateral force.

  13. A bench-scale biotreatability methodology to evaluate field bioremediation

    International Nuclear Information System (INIS)

    Saberiyan, A.G.; MacPherson, J.R. Jr.; Moore, R.; Pruess, A.J.; Andrilenas, J.S.

    1995-01-01

    A bench-scale biotreatability methodology was designed to assess field bioremediation of petroleum contaminated soil samples. This methodology was performed successfully on soil samples from more than 40 sites. The methodology is composed of two phases, characterization and experimentation. The first phase is physical, chemical, and biological characterization of the contaminated soil sample. This phase determines soil parameters, contaminant type, presence of indigenous contaminant-degrading bacteria, and bacterial population size. The second phase, experimentation, consists of a respirometry test to measure the growth of microbes indirectly (via generation of CO 2 ) and the consumption of their food source directly (via contaminant loss). Based on a Monod kinetic analysis, the half-life of a contaminant can be calculated. Abiotic losses are accounted for based on a control test. The contaminant molecular structure is used to generate a stoichiometric equation. The stoichiometric equation yields a theoretical ratio for mg of contaminant degraded per mg of CO 2 produced. Data collected from the respirometry test are compared to theoretical values to evaluate bioremediation feasibility

  14. On-site cell field test support program

    Science.gov (United States)

    Staniunas, J. W.; Merten, G. P.

    1982-09-01

    Utility sites for data monitoring were reviewed and selected. Each of these sites will be instrumented and its energy requirements monitored and analyzed for one year prior to the selection of 40 Kilowatt fuel cell field test sites. Analyses in support of the selection of sites for instrumentation shows that many building sectors offered considerable market potential. These sectors include nursing home, health club, restaurant, industrial, hotel/motel and apartment.

  15. Field Test of Gopher Tortoise (Gopherus Polyphemus) Population Estimation Techniques

    Science.gov (United States)

    2008-04-01

    Web (WWW) at URL: http://www.cecer.army.mil ERDC/CERL TR-08-7 4 2 Field Tests The gopher tortoise is a species of conservation concern in the... ncv D ⎛ ⎞⎛ ⎞ = ⎜ ⎟⎜ ⎟ ⎝ ⎠⎝ ⎠ (4) where: L = estimate of line length to be sampled b = dispersion parameter 2ˆ( )tcv D = desired coefficient of

  16. The virtual fields method applied to spalling tests on concrete

    Directory of Open Access Journals (Sweden)

    Forquin P.

    2012-08-01

    Full Text Available For one decade spalling techniques based on the use of a metallic Hopkinson bar put in contact with a concrete sample have been widely employed to characterize the dynamic tensile strength of concrete at strain-rates ranging from a few tens to two hundreds of s−1. However, the processing method mainly based on the use of the velocity profile measured on the rear free surface of the sample (Novikov formula remains quite basic and an identification of the whole softening behaviour of the concrete is out of reach. In the present paper a new processing method is proposed based on the use of the Virtual Fields Method (VFM. First, a digital high speed camera is used to record the pictures of a grid glued on the specimen. Next, full-field measurements are used to obtain the axial displacement field at the surface of the specimen. Finally, a specific virtual field has been defined in the VFM equation to use the acceleration map as an alternative ‘load cell’. This method applied to three spalling tests allowed to identify Young’s modulus during the test. It was shown that this modulus is constant during the initial compressive part of the test and decreases in the tensile part when micro-damage exists. It was also shown that in such a simple inertial test, it was possible to reconstruct average axial stress profiles using only the acceleration data. Then, it was possible to construct local stress-strain curves and derive a tensile strength value.

  17. The forced flow high field test facility SULTAN

    International Nuclear Information System (INIS)

    Horvath, I.; Vecsey, G.; Weymuth, P.

    1984-01-01

    The construction of the 8 Tesla, 1 m bore Test Facility SULTAN - I, a common action of ENEA (I-Frascati), ECN (NL-Petten) and SIN (CH-Villigen), is completed. Results on assembly, cooldown and the first operation of the whole system are presented. The SULTAN facility provides a wide range of capability of parameter variations (field, current, cooling) for the investigation of steady state performance and stability of technical superconductors unders nominal and limiting conditions

  18. Dispersant field testing : a review of procedures and considerations

    International Nuclear Information System (INIS)

    Fingas, M.F.

    2004-01-01

    The effectiveness of a dispersant is defined by the amount of oil that the dispersant puts into the water column compared to the amount of oil that was initially spilled. Effectiveness is generally determined visually in plumes of dispersed oil that are visible from ships and aircraft. This paper describes 25 specific issues and technical concerns regarding field testing of dispersant effectiveness. Recent field tests were reviewed and literature that relates to testing procedures was sited. The 25 factors that are important for the appropriate outcome of dispersant field experiments include: mass balance; proper controls; analytical method; differential plume movement; time lag and length of time followed; mathematics of calculation and integration; lower and upper limits of analytical methods; use of remote sensing; thickness measurement; behaviour of oil with surfactant content; surfactant stripping; tracking surface oil and dispersed oil; recovering surface oil; visibility of oil from the surface; background levels of hydrocarbons; fluorescence of dispersant; herding; emulsion breaking; application success; heterogeneity of slick and plume; deposition measurements; true analytical standards; effect of wind on dispersant and slick; dispersant run-off; and weathering of the oil. It was concluded that the most important factors are the ability to determine mass balance, use proper controls, analytical methods and to avoid procedures that give incorrect results. 34 refs., 4 tabs., 1 fig

  19. Neuroethological validation of an experimental apparatus to evaluate oriented and non-oriented escape behaviours: Comparison between the polygonal arena with a burrow and the circular enclosure of an open-field test.

    Science.gov (United States)

    Biagioni, Audrey Francisco; dos Anjos-Garcia, Tayllon; Ullah, Farhad; Fisher, Isaac René; Falconi-Sobrinho, Luiz Luciano; de Freitas, Renato Leonardo; Felippotti, Tatiana Tocchini; Coimbra, Norberto Cysne

    2016-02-01

    Inhibition of GABAergic neural inputs to dorsal columns of the periaqueductal grey matter (dPAG), posterior (PH) and dorsomedial (DMH) hypothalamic nuclei elicits distinct types of escape behavioural reactions. To differentiate between the variety and intensity of panic-related behaviours, the pattern of defensive behaviours evoked by blockade of GABAA receptors in the DMH, PH and dPAG were compared in a circular open-field test and in a recently designed polygonal arena. In the circular open-field, the defensive behaviours induced by microinjection of bicuculline into DMH and PH were characterised by defensive alertness behaviour and vertical jumps preceded by rearing exploratory behaviour. On the other hand, explosive escape responses interspersed with horizontal jumps and freezing were observed after the blockade of GABAA receptors on dPAG neurons. In the polygonal arena apparatus, the escape response produced by GABAergic inhibition of DMH and PH neurons was directed towards the burrow. In contrast, the blockade of GABAA receptors in dPAG evoked non-oriented escape behaviour characterised by vigorous running and horizontal jumps in the arena. Our findings support the hypothesis that the hypothalamic nuclei organise oriented escape behavioural responses whereas non-oriented escape is elaborated by dPAG neurons. Additionally, the polygonal arena with a burrow made it easy to discriminate and characterise these two different patterns of escape behavioural responses. In this sense, the polygonal arena with a burrow can be considered a good methodological tool to discriminate between these two different patterns of escape behavioural responses and is very useful as a new experimental animal model of panic attacks. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Grimsel Test Site: modelling radionuclide migration field experiments

    International Nuclear Information System (INIS)

    Heer, W.; Hadermann, J.

    1994-09-01

    In the migration field experiments at Nagra's Grimsel Test Site, the processes of nuclide transport through a well defined fractured shear-zone in crystalline rock are being investigated. For these experiments, model calculations have been performed to obtain indications on validity and limitation of the model applied and the data deduced under field conditions. The model consists of a hydrological part, where the dipole flow fields of the experiments are determined, and a nuclide transport part, where the flow field driven nuclide propagation through the shear-zone is calculated. In addition to the description of the model, analytical expressions are given to guide the interpretation of experimental results. From the analysis of experimental breakthrough curves for conservative uranine, weakly sorbing sodium and more stronger sorbing strontium tracers, the following main results can be derived: i) The model is able to represent the breakthrough curves of the migration field experiments to a high degree of accuracy, ii) The process of matrix diffusion is manifest through the tails of the breakthrough curves decreasing with time as t -3/2 and through the special shape of the tail ends, both confirmed by the experiments, iii) For nuclide sorbing rapidly, not too strongly, linearly, and exhibiting a reversible cation exchange process on fault gouge, the laboratory sorption coefficient can reasonably well be extrapolated to field conditions. Adequate care in selecting and preparing the rock samples is, of course, a necessary requirement. Using the parameters determined in the previous analysis, predictions are made for experiments in a smaller an faster flow field. For conservative uranine and weakly sorbing sodium, the agreement of predicted and measured breakthrough curves is good, for the more stronger sorbing strontium reasonable, confirming that the model describes the main nuclide transport processes adequately. (author) figs., tabs., 29 refs

  1. Preparation of the ITER Poloidal Field Conductor Insert (PFCI) test

    International Nuclear Information System (INIS)

    Zanino, R.; Egorov, S.; Kim, K.; Martovetsky, N.; Nunoya, Y.; Okuno, K.; Salpietro, E.; Sborchia, C.; Takahashi, Y.; Weng, P.; Bangasco, M.; Savoldi Richard, L.; Polak, M.; Formisano, A.; Zapretilina, E.; Shikov, A.; Vedernikov, G.; Ciazynski, D.; Zani, L.; Muzzi, L.; Ricci, M.; Deela Corte, A.; Sugimoto, M.; Hamada, K.; Portone, A.; Hurd, F.; Mitchell, N.; Nijhuis, A.; Ilyin, Y.

    2004-01-01

    The Poloidal Field Conductor Insert (PFCI) of the International Thermonuclear Experimental Reactor (ITER) has been designed in Europe and is being manufactured at Tesla Engineering, UK, in the frame of a Task Agreement with the ITER International Team. Completion of the PFCI is expected at the beginning of 2005. Then, the coil shall be shipped to JAERI Naka, Japan, and inserted into the bore of the ITER Central Solenoid Model Coil, where it should be tested in 2005 to 2006. The PFCI consists of a NbTi dual-channel conductor, almost identical to the ITER PF1 and PF6 design, about 45 m long, with a 50 mm thick square stainless steel jacket, wound in a single-layer solenoid. It should carry up to 50 kA in a field of about 6 T, and it will be cooled by supercritical He at around 4.5 K and 0.6 MPa. An intermediate joint, representative of the ITER PF joints and located at relatively high field, will be an important new item in the test configuration with respect to the previous ITER Insert Coils. The PFCI will be fully instrumented with inductive and resistive heaters, as well as with voltage taps, Hall probes, pick-up coils, temperature sensors, pressure taps, strain and displacement sensors. The test program shall be aimed at DC and pulsed performance assessment of conductor and intermediate joint, AC loss measurement, stability and quench propagation, thermalhydraulic characterization. Here we give an overview of the preparatory work towards the test, including a review of the coil manufacturing and of the available instrumentation, a discussion of the most likely test program items, and a presentation of the supporting modeling and characterization work performed so far. (authors)

  2. Deep Borehole Field Test Requirements and Controlled Assumptions.

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Ernest [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-07-01

    This document presents design requirements and controlled assumptions intended for use in the engineering development and testing of: 1) prototype packages for radioactive waste disposal in deep boreholes; 2) a waste package surface handling system; and 3) a subsurface system for emplacing and retrieving packages in deep boreholes. Engineering development and testing is being performed as part of the Deep Borehole Field Test (DBFT; SNL 2014a). This document presents parallel sets of requirements for a waste disposal system and for the DBFT, showing the close relationship. In addition to design, it will also inform planning for drilling, construction, and scientific characterization activities for the DBFT. The information presented here follows typical preparations for engineering design. It includes functional and operating requirements for handling and emplacement/retrieval equipment, waste package design and emplacement requirements, borehole construction requirements, sealing requirements, and performance criteria. Assumptions are included where they could impact engineering design. Design solutions are avoided in the requirements discussion. Deep Borehole Field Test Requirements and Controlled Assumptions July 21, 2015 iv ACKNOWLEDGEMENTS This set of requirements and assumptions has benefited greatly from reviews by Gordon Appel, Geoff Freeze, Kris Kuhlman, Bob MacKinnon, Steve Pye, David Sassani, Dave Sevougian, and Jiann Su.

  3. Design and Installation of a Disposal Cell Cover Field Test

    Energy Technology Data Exchange (ETDEWEB)

    Benson, C.H. [University of Wisconsin–Madison, Madison, Wisconsin; Waugh, W.J. [S.M. Stoller Corporation, Grand Junction, Colorado; Albright, W.H. [Desert Research Institute, Reno, Nevada; Smith, G.M. [Geo-Smith Engineering, Grand Junction, Colorado; Bush, R.P. [U.S. Department of Energy, Grand Junction, Colorado

    2011-02-27

    The U.S. Department of Energy’s Office of Legacy Management (LM) initiated a cover assessment project in September 2007 to evaluate an inexpensive approach to enhancing the hydrological performance of final covers for disposal cells. The objective is to accelerate and enhance natural processes that are transforming existing conventional covers, which rely on low-conductivity earthen barriers, into water balance covers, that store water in soil and release it as soil evaporation and plant transpiration. A low conductivity cover could be modified by deliberately blending the upper layers of the cover profile and planting native shrubs. A test facility was constructed at the Grand Junction, Colorado, Disposal Site to evaluate the proposed methodology. The test cover was constructed in two identical sections, each including a large drainage lysimeter. The test cover was constructed with the same design and using the same materials as the existing disposal cell in order to allow for a direct comparison of performance. One test section will be renovated using the proposed method; the other is a control. LM is using the lysimeters to evaluate the effectiveness of the renovation treatment by monitoring hydrologic conditions within the cover profile as well as all water entering and leaving the system. This paper describes the historical experience of final covers employing earthen barrier layers, the design and operation of the lysimeter test facility, testing conducted to characterize the as-built engineering and edaphic properties of the lysimeter soils, the calibration of instruments installed at the test facility, and monitoring data collected since the lysimeters were constructed.

  4. Evaluation of uncertainty in the measurement of environmental electromagnetic fields

    International Nuclear Information System (INIS)

    Vulevic, B.; Osmokrovic, P.

    2010-01-01

    With regard to Non-ionising radiation protection, the relationship between human exposure to electromagnetic fields and health is controversial. Electromagnetic fields have become omnipresent in the daily environment. This paper assesses the problem of how to compare a measurement result with a limit fixed by the standard for human exposure to electric, magnetic and electromagnetic fields (0 Hz-300 GHz). The purpose of the paper is an appropriate representation of the basic information about evaluation of measurement uncertainty. (authors)

  5. Results of ITER toroidal field coil cover plate welding test

    International Nuclear Information System (INIS)

    Koizumi, Norikiyo; Matsui, Kunihiro; Shimizu, Tatsuya; Nakajima, Hideo; Iijima, Ami; Makino, Yoshinobu

    2012-01-01

    In ITER Toroidal Field (TF) coils, cover plates (CP) are welded to the teeth of the radial plate (RP) to fix conductors in the grooves of the RP. Though the total length of the welds is approximately 1.5 km and the height and width of the RP are 14 and 9 m, respectively, welding deformation of smaller than 1 mm for local out-of-plane distortion and smaller than several millimeters for in-plane deformation is required. Therefore, laser welding is used for CP welding to reduce welding deformation as much as possible. However, the gap in welding joints is expected to be a maximum of 0.5 mm. Thus, a laser welding technique to enable welding of joints with a gap of 0.5 mm in width has been developed. Applying this technology, a CP welding trial using an RP mock-up was successfully performed. The achieved local flatness, that is, the flatness of the cross-section of the RP mock-up, is 0.6 mm. The analysis using inherent strains, which are derived from the welding test using flat plates, also indicates that better local flatness can be achieved if the initial distortion is zero. In addition, the welding deformation of a full-scale RP is evaluated via analysis using the inherent strain. The analytical results show that in-plane deformation is approximately 5 mm and large out-of-plane deformation, consisting of approximately 5 mm-long wave distortion and a twist of approximately 1.5 mm in the RP cross-section, is generated. It is expected that the required profile can be achieved by determining the original geometry of an RP by simulating deformation during welding. It is also expected that the required local flatness of a DP can be achieved, since out-of-plane deformation can be reduced by increasing the number of RPs turned over during CP welding. A more detailed study is required. (author)

  6. Standard Guide for Conducting Corrosion Tests in Field Applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide covers procedures for conducting corrosion tests in plant equipment or systems under operating conditions to evaluate the corrosion resistance of engineering materials. It does not cover electrochemical methods for determining corrosion rates. 1.1.1 While intended primarily for immersion tests, general guidelines provided can be applicable for exposure of test specimens in plant atmospheres, provided that placement and orientation of the test specimens is non-restrictive to air circulation. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See also 10.4.2.

  7. Fabrication and testing of the Nb3Sn superconductor for High-Field Test Facility (HFTF)

    International Nuclear Information System (INIS)

    Spencer, C.; Adam, E.; Gregory, E.; Marancik, W.; Sanger, P.; Scanlan, R.; Cornish, D.

    1979-01-01

    A 5000 A-12 T fully stable Nb 3 Sn superconductor has to be produced for the insert magnet of the high-field test facility being built at Lawrence Livermore Laboratory. A process is described which permits the fabrication of long lengths of large fully transposed monolithic superconductors containing in excess of 100,000 filaments of Nb 3 Sn. Measurements of critical current as a function of magnetic field and longitudinal strain on prototype samples are reported

  8. Relationships Between Anaerobic Performance, Field Tests and Game Performance of Sitting Volleyball Players

    Directory of Open Access Journals (Sweden)

    Marszalek Jolanta

    2015-12-01

    Full Text Available The aim of this study was to evaluate relationships between anaerobic performance, field tests, game performance and anthropometric variables of sitting volleyball players. Twenty elite Polish sitting volleyball players were tested using the 30 s Wingate Anaerobic Test for arm crank ergometer and participated in six physical field tests. Heights in position to block and to spike, as well as arm reach were measured. Players were observed during the game on the court in terms of effectiveness of the serve, block, attack, receive and defense. Pearson analysis and the Spearman's rank correlation coefficient were used. The strongest correlations were found between the chest pass test and mean power and peak power (r=.846; p=.001 and r=.708; p=.0005, respectively, and also between the T-test and peak power (r= −.718; p=.001. Mean power correlated with the 3 m test (r= −.540; p=.014, the 5 m test (r= −.592; p=.006, and the T-test (r= −.582; p=.007. Peak power correlated with the 3 m test (r= −.632; p=.003, the 5 m test (r= −.613; p=.004, speed & agility (r= −.552; p=.012 and speed & endurance (r=−.546; p=.013. Significant correlations were observed between anthropometric parameters and anaerobic performance variables (p≤.001, and also between anthropometric parameters and field tests (p≤.05. Game performance and physical fitness of sitting volleyball players depended on their anthropometric variables: reach of arms, the position to block and to spike. The chest pass test could be used as a non-laboratory field test of anaerobic performance of sitting volleyball players.

  9. Small-scale field test of simple earthen covers for uranium mill tailings

    International Nuclear Information System (INIS)

    Nielson, K.K.; Rogers, V.C.; Rich, D.C.

    1983-01-01

    A series of field tests has been conducted during the past year to provide benchmark data on the performance of simple, single-layer earthen covers at thee uranium tailings sites. The performance of the covers was evaluated in terms of their reduction of radon gas releases, although moisture profiles and other cover parameters were also monitored. The tests were designed to evaluate the effectiveness of local soils applied with minimum engineering design or compaction effort. The tests, therefore, tend to represent a lowest-cost, and perhaps a worst-case scenario for tailings reclamation. The field benchmark tests are part of a major research program being conducted by the US Department of Energy to develop technology for uranium tailings disposal. The present tests with simple earthen covers thus provide a comparative basis for evaluating the effectiveness of more highly-engineered systems and their proportionately higher costs. These tests were conducted on the inactive tailings piles at Salt Lake City; Mexican Hat, Utah; and Grand Junction, Colorado. The test covers were installed during the summer of 1981 (Ri81) and have been monitored during the following year. This report describes the experimental details of the cover tests, the data that were collected during the one-year monitoring period, and the conclusions that were drawn from the experiments. 5 refs., 5 figs., 13 tabs

  10. Field and laboratory test methods for geomembranes during waste management facility construction

    International Nuclear Information System (INIS)

    Allen, S.R.; McCutchan, J.B.

    1991-01-01

    Hazardous waste management facilities are required to use approved lining and leak detection systems to prevent the migration of waste into the environment. Synthetic flexible membrane liners (FMLs) have effectively served as the critical barrier for waste containment and fluid migration. The U.S. EPA has established minimum technology requirements for the construction of lined facilities that include detailed and documented Construction Quality Assurance (CQA) plans. The U.S. EPA (EPA) recognizes that CQA during field construction is imperative for successful completion of project work and long-term facility operation. This paper discusses the importance of CQA during FML installation and the practical aspects of implementing a successful CQA program. Standard methods used for FML evaluation, in both the field and laboratory, are discussed and specific aspects of seam testing and data evaluation are addressed. The general importance of comprehensive definition of geomembrane seam field failures is strongly emphasized so that an appropriate response to test failures can be recommended

  11. Results from Field Testing the RIMFAX GPR on Svalbard.

    Science.gov (United States)

    Hamran, S. E.; Amundsen, H. E. F.; Berger, T.; Carter, L. M.; Dypvik, H.; Ghent, R. R.; Kohler, J.; Mellon, M. T.; Nunes, D. C.; Paige, D. A.; Plettemeier, D.; Russell, P.

    2017-12-01

    The Radar Imager for Mars' Subsurface Experiment - RIMFAX is a Ground Penetrating Radar being developed for NASÁs MARS 2020 rover mission. The principal goals of the RIMFAX investigation are to image subsurface structures, provide context for sample sites, derive information regarding subsurface composition, and search for ice or brines. In meeting these goals, RIMFAX will provide a view of the stratigraphic section and a window into the geological and environmental history of Mars. To verify the design an Engineering Model (EM) of the radar was tested in the field in the spring 2017. Different sounding modes on the EM were tested in different types of subsurface geology on Svalbard. Deep soundings were performed on polythermal glaciers down to a couple of hundred meters. Shallow soundings were used to map a ground water table in the firn area of a glacier. A combination of deep and shallow soundings was used to image buried ice under a sedimentary layer of a couple of meters. Subsurface sedimentary layers were imaged down to more than 20 meters in sand stone permafrost. This presentation will give an overview of the RIMFAX investigation, describe the development of the radar system, and show results from field tests of the radar.

  12. TEST OF AN ANIMAL DRAWN FIELD IMPLEMENT CART

    Directory of Open Access Journals (Sweden)

    Paolo Spugnoli

    2008-06-01

    Full Text Available The field performance of a horse-drawn hitch cart equipped with a PTO system powered by the two cart ground wheels have been investigated. For this purpose field tests on clay and turf soil, with varying ballast and PTO torque, have been carried out pulling the cart by a tractor. Preliminary tests were aimed at assessing the traction capability of horse breed. These tests showed that the mean draught force given by two of these horses was 173daN, average working speed was about 1m*s-1, resulting a mean draught power developed by each horse of about 0.86kW. The PTO cart system performance has shown that the torque has not exceeded 2.4daN*m, maximum draught or PTO power was 1.15kW, rotation speed just higher than 400min-1, with mean efficiency of about 50%. These values are consistent with horse performance and small haymaking, fertilizing, seeding and chemical application machine requirements.

  13. Leaching of saltstone: Laboratory and field testing and mathematical modeling

    International Nuclear Information System (INIS)

    Grant, M.W.; Langton, C.A.; Oblath, S.B.; Pepper, D.W.; Wallace, R.M.; Wilhite, E.L.; Yau, W.W.F.

    1987-01-01

    A low-level alkaline salt solution will be a byproduct in the processing of high-level waste at the Savannah River Plant (SRP). This solution will be incorporated into a wasteform, saltstone, and disposed of in surface vaults. Laboratory and field leach testing and mathematical modeling have demonstrated the predictability of contaminant release from cement wasteforms. Saltstone disposal in surface vaults will meet the design objective, which is to meet drinking water standards in shallow groundwater at the disposal area boundary. Diffusion is the predominant mechanism for release of contaminants to the environment. Leach testing in unsaturated soil, at soil moisture levels above 1 wt %, has shown no difference in leach rate compared to leaching in distilled water. Field leach testing of three thirty-ton blocks of saltstone in lysimeters has been underway since January 1984. Mathematical models were applied to assess design features for saltstone disposal. One dimensional infinite-composite and semi-infinite analytical models were developed for assessing diffusion of nitrate from saltstone through a cement barrier. Numerical models, both finite element and finite difference, were validated by comparison of model predictions with the saltstone lysimeter results. Validated models were used to assess the long-term performance of the saltstone stored in surface vaults. The maximum concentrations of all contaminants released from saltstone to shallow groundwater are predicted to be below drinking water standards at the disposal area boundary. 5 refs., 11 figs., 5 tabs

  14. Fault detection by surface seismic scanning tunneling macroscope: Field test

    KAUST Repository

    Hanafy, Sherif M.

    2014-08-05

    The seismic scanning tunneling macroscope (SSTM) is proposed for detecting the presence of near-surface impedance anomalies and faults. Results with synthetic data are consistent with theory in that scatterers closer to the surface provide brighter SSTM profiles than those that are deeper. The SSTM profiles show superresolution detection if the scatterers are in the near-field region of the recording line. The field data tests near Gulf of Aqaba, Haql, KSA clearly show the presence of the observable fault scarp, and identify the subsurface presence of the hidden faults indicated in the tomograms. Superresolution detection of the fault is achieved, even when the 35 Hz data are lowpass filtered to the 5-10 Hz band.

  15. Detailed field test of yaw-based wake steering

    DEFF Research Database (Denmark)

    Fleming, P.; Churchfield, M.; Scholbrock, A.

    2016-01-01

    production. In the first phase, a nacelle-mounted scanning lidar was used to verify wake deflection of a misaligned turbine and calibrate wake deflection models. In the second phase, these models were used within a yaw controller to achieve a desired wake deflection. This paper details the experimental......This paper describes a detailed field-test campaign to investigate yaw-based wake steering. In yaw-based wake steering, an upstream turbine intentionally misaligns its yaw with respect to the inflow to deflect its wake away from a downstream turbine, with the goal of increasing total power...... design and setup. All data collected as part of this field experiment will be archived and made available to the public via the U.S. Department of Energy’s Atmosphere to Electrons Data Archive and Portal....

  16. Fault detection by surface seismic scanning tunneling macroscope: Field test

    KAUST Repository

    Hanafy, Sherif M.; Schuster, Gerard T.

    2014-01-01

    The seismic scanning tunneling macroscope (SSTM) is proposed for detecting the presence of near-surface impedance anomalies and faults. Results with synthetic data are consistent with theory in that scatterers closer to the surface provide brighter SSTM profiles than those that are deeper. The SSTM profiles show superresolution detection if the scatterers are in the near-field region of the recording line. The field data tests near Gulf of Aqaba, Haql, KSA clearly show the presence of the observable fault scarp, and identify the subsurface presence of the hidden faults indicated in the tomograms. Superresolution detection of the fault is achieved, even when the 35 Hz data are lowpass filtered to the 5-10 Hz band.

  17. Spinning test particles in the field of a black hole

    Energy Technology Data Exchange (ETDEWEB)

    Tod, K P; de Felice, F [Padua Univ. (Italy); Calvani, M [Padua Univ. (Italy). Istituto di Astronomia

    1976-08-11

    It is studied the motion of spinning test bodies in the gravitational field of a rotating black hole, confining the examination of the pole-dipole approximation and of the special case of motion in the equatorial plane with the spin vector perpendicular to it. The study also provides the locus of the turning points for the equatorial orbits and also the exact limits of validity of the pole-dipole approximation for any given set of particle parameters. The innermost stable circular orbits are studied in details, and it is found that opposite spinning accreting particles are separated by the gravitational field of the black hole and that the fraction of energy ''at infinity'' which can be extracted when the particle spin is opposite to that of the black hole can be as high as 100%.

  18. Field test of a post-closure radiation monitor

    International Nuclear Information System (INIS)

    Reed, S.; Christy, C.E.; Heath, R.E.

    1995-01-01

    The DOE is conducting remedial actions at many sites contaminated with radioactive materials. After closure of these sites, long-term subsurface monitoring is typically required by law. This monitoring is generally labor intensive and expensive using conventional sampling and analysis techniques. The U.S. Department of Energy's Morgantown Energy Technology Center (METC) has contracted with Babcock and Wilcox to develop a Long-Term Post-Closure Radiation Monitoring System (LPRMS) to reduce these monitoring costs. A prototype LPRMS probe was built, and B ampersand W and FERMCO field tested this monitoring probe at the Fernald Environmental Management Project in the fall of 1994 with funding from the DOE's Office of Technology Development (EM-50) through METC. The system was used to measure soil and water with known uranium contamination levels, both in drums and in situ at depths up to 3 meters. For comparison purposes, measurements were also performed using a more conventional survey probe with a sodium iodide scintillator directly butt-coupled to detection electronics. This paper presents a description and the results of the field tests. The results were used to characterize the lower detection limits, precision and bias of the system, which allowed the DOE to judge the monitoring system's ability to meet its long-term post-closure radiation monitoring needs. Based on the test results, the monitoring system has been redesigned for fabrication and testing in a potential Phase III of this program. If the DOE feels that this system can meet its needs and chooses to continue into Phase III of this program, this redesigned full scale prototype system will be built and tested for a period of approximately a year. Such a system can be used at a variety of radioactively contaminated sites

  19. Evaluation of nine HIV rapid test kits to develop a national HIV testing algorithm in Nigeria

    Directory of Open Access Journals (Sweden)

    Orji Bassey

    2015-05-01

    Full Text Available Background: Non-cold chain-dependent HIV rapid testing has been adopted in many resource-constrained nations as a strategy for reaching out to populations. HIV rapid test kits (RTKs have the advantage of ease of use, low operational cost and short turnaround times. Before 2005, different RTKs had been used in Nigeria without formal evaluation. Between 2005 and 2007, a study was conducted to formally evaluate a number of RTKs and construct HIV testing algorithms. Objectives: The objectives of this study were to assess and select HIV RTKs and develop national testing algorithms. Method: Nine RTKs were evaluated using 528 well-characterised plasma samples. These comprised 198 HIV-positive specimens (37.5% and 330 HIV-negative specimens (62.5%, collected nationally. Sensitivity and specificity were calculated with 95% confidence intervals for all nine RTKs singly and for serial and parallel combinations of six RTKs; and relative costs were estimated. Results: Six of the nine RTKs met the selection criteria, including minimum sensitivity and specificity (both ≥ 99.0% requirements. There were no significant differences in sensitivities or specificities of RTKs in the serial and parallel algorithms, but the cost of RTKs in parallel algorithms was twice that in serial algorithms. Consequently, three serial algorithms, comprising four test kits (BundiTM, DetermineTM, Stat-Pak® and Uni-GoldTM with 100.0% sensitivity and 99.1% – 100.0% specificity, were recommended and adopted as national interim testing algorithms in 2007. Conclusion: This evaluation provides the first evidence for reliable combinations of RTKs for HIV testing in Nigeria. However, these RTKs need further evaluation in the field (Phase II to re-validate their performance.

  20. Field test and mathematical modeling of bioremediation of an oil-contaminated soil. Part 1: Field test

    International Nuclear Information System (INIS)

    Li, K.Y.; Xu, T.; Colapret, J.A.; Cawley, W.A.; Bonner, J.S.; Ernest, A.; Verramachaneni, P.B.

    1994-01-01

    A fire-wall area (about 270 ft x 310 ft) with the Bunker C oil contaminated soil was selected for the bioremediation field test. This fire-wall area was separated into 18 plots by dirt dikes to test 6 bioremediation methods with three tests of each method. The six treatment methods were: (a) aeration with basic nutrients and indigenous organisms (BNIO); (b) aeration with basic nutrients and inoculation from a refinery wastewater treatment facility (BNSIWT); (c) aeration with an oleophilic fertilizer and indigenous organisms (INIPOL); (d) aeration with basic nutrients and biosurfactant organisms (EPA Seal Beach consortia) (EPA); (e) aeration with proprietary nutrients and organisms (PRO); and (f) aeration only for active control (CONTROL). This field test was conducted for 91 days. In general the oil contents in 18 plots were reduced, but the results showed significant fluctuations. A statistical method was used to examine if the oil reductions of six methods were the results from the random error of sampling and sample analysis or biodegradation. The results of the statistical analysis showed that oil reduction was concluded from all but the plots of PRO. From the data analysis, it may be concluded that the oil reduction rate in these studies is controlled by oil transfer from soil into the aqueous solution. An example of calculation was used to illustrate this conclusion

  1. Test plan for FY-94 digface characterization field experiments

    International Nuclear Information System (INIS)

    Josten, N.E.; Roybal, L.G.

    1994-08-01

    The digface characterization concept has been under development at the Idaho National Engineering Laboratory (INEL) since fiscal year (FY) 1992 through the support of the Buried Waste Integrated Demonstration Program. A digface characterization system conducts continuous subsurface characterization simultaneously with retrieval of hazardous and radioactive waste from buried waste sites. The system deploys multiple sensors at the retrieval operation digface and collects data that provide a basis for detecting, locating, and classifying buried materials and hazardous conditions before they are disturbed by the retrieval equipment. This test plan describes ongoing efforts to test the digface characterization concept at the INEL's Cold Test Pit using a simplified prototype deployment apparatus and off-the-shelf sensors. FY-94 field experiments will explore problems in object detection and classification. Detection and classification of objects are fundamental to three of the four primary functions of digface characterization during overburden removal. This test plan establishes procedures for collecting and validating the digface characterization data sets. Analysis of these data will focus on testing and further developing analysis methods for object detection and classification during overburden removal

  2. Layout of the objects of underground nuclear tests at the Balapan test field of the former Semipalatinsk test site

    International Nuclear Information System (INIS)

    Konovalov, V.E.; Gryaznov, O.V.

    2000-01-01

    Integrated research of practical and scientific interest is conducted at the Balapan test field of the Semipalatinsk test site. The lack of the reliable locations for features associated with nuclear testing causes considerable difficulties while carrying out the research. To fill this gap the authors present data available at the Institute of Geophysical Research of the National Nuclear Center of the Republic of Kazakhstan. (author)

  3. Alternative filtration testing program: Pre-evaluation of test results

    International Nuclear Information System (INIS)

    Georgeton, G.K.; Poirier, M.R.

    1990-01-01

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing

  4. Alternative filtration testing program: Pre-evaluation of test results

    Energy Technology Data Exchange (ETDEWEB)

    Georgeton, G.K.; Poirier, M.R.

    1990-09-28

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing.

  5. Field Lysimeter Test Facility for protective barriers: Experimental plan

    International Nuclear Information System (INIS)

    Kirkham, R.R.; Gee, G.W.; Downs, J.L.

    1987-12-01

    This document was first written in October 1986 and has been used to guide the design of the Field Lysimeter Test Facility (FLTF) and to promote discussions between research and engineering staff regarding the selection of barrier treatments for inclusion in the FLTF. The construction of the lysimeter facility was completed June 28, 1987. This document describes the facility, the treatments placed in each lysimeter, types of measurements made in each lysimeter, and a brief discussion of project activities related to quality assurance, safety, and funding requirements. The treatment description and figures have been updated to reflect the lysimeter facility as constructed. 12 refs., 6 figs., 5 tabs

  6. Pulsed mixed n, γ radiation fields for electronic testing

    International Nuclear Information System (INIS)

    Nurdin, G.; Becret, C.; Jaureguy, J.C.; Vie, M.; Baboulet, J.P.; Lapeyre, P.; Ramisse, D.

    1994-01-01

    For combined n, γ TREE testing we have modified the CALIBAN Fast Burst Reactor Field with CdO/Epoxy converters to cover the range [10 11 -10 12 ] n.cm -2 (1 MeV Si), [10 7 - 10 8 ] cGy(Si).s -1 . Activation and fission σ φvector, 1 MeV(Si) fluences, neutron spectra, total exposures and dose rates were predicted with good agreement by n, γ photon transport codes. (author). 12 refs., 2 figs., 1 tab

  7. Parallelization of ultrasonic field simulations for non destructive testing

    International Nuclear Information System (INIS)

    Lambert, Jason

    2015-01-01

    The Non Destructive Testing field increasingly uses simulation. It is used at every step of the whole control process of an industrial part, from speeding up control development to helping experts understand results. During this thesis, a fast ultrasonic field simulation tool dedicated to the computation of an ultrasonic field radiated by a phase array probe in an isotropic specimen has been developed. During this thesis, a simulation tool dedicated to the fast computation of an ultrasonic field radiated by a phased array probe in an isotropic specimen has been developed. Its performance enables an interactive usage. To benefit from the commonly available parallel architectures, a regular model (aimed at removing divergent branching) derived from the generic CIVA model has been developed. First, a reference implementation was developed to validate this model against CIVA results, and to analyze its performance behaviour before optimization. The resulting code has been optimized for three kinds of parallel architectures commonly available in workstations: general purpose processors (GPP), many-core co-processors (Intel MIC) and graphics processing units (nVidia GPU). On the GPP and the MIC, the algorithm was reorganized and implemented to benefit from both parallelism levels, multithreading and vector instructions. On the GPU, the multiple steps of field computing have been divided in multiple successive CUDA kernels. Moreover, libraries dedicated to each architecture were used to speedup Fast Fourier Transforms, Intel MKL on GPP and MIC and nVidia cuFFT on GPU. Performance and hardware adequation of the produced codes were thoroughly studied for each architecture. On multiple realistic control configurations, interactive performance was reached. Perspectives to address more complex configurations were drawn. Finally, the integration and the industrialization of this code in the commercial NDT platform CIVA is discussed. (author) [fr

  8. Field tests of 2- and 40-tube condensers at the East Mesa Geothermal Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, R.W.; Domingo, N.

    1982-05-01

    Two water-cooled isobutane condensers, one with 2 tubes and one with 40 tubes, were subjected to field tests at the East Mesa Geothermal Test Site to assess relative heat transfer performance in both surface evaporator and direct-contact evaporator modes. The five groups of tests established that field performance was below earlier laboratory-determined levels and that direct-contact evaporator mode performance was poorer than that for the surface evaporator mode. In all test situations, fluted condenser tubes performed better than smooth condenser tubes. Cooling water quality had no significant effect on performance, but brine preflash in the direct-contact mode did promote some relative performance improvement. Important implications of these results for binary geothermal power plants are that (1) working-fluid-side impurities can significantly degrade heat transfer performance of the power plant condensers and (2) provisions for minimizing such impurities may be required.

  9. Integrated Locomotor Function Tests for Countermeasure Evaluation

    Science.gov (United States)

    Bloomberg, J. J.; Mulavara, A. P.; Peters, B. T.; Cohen, H. S.; Landsness, E. C.; Black, F. O.

    2005-01-01

    Following spaceflight crewmembers experience locomotor dysfunction due to inflight adaptive alterations in sensorimotor function. Countermeasures designed to mitigate these postflight gait alterations need to be assessed with a new generation of tests that evaluate the interaction of various sensorimotor sub-systems central to locomotor control. The goal of the present study was to develop new functional tests of locomotor control that could be used to test the efficacy of countermeasures. These tests were designed to simultaneously examine the function of multiple sensorimotor systems underlying the control of locomotion and be operationally relevant to the astronaut population. Traditionally, gaze stabilization has been studied almost exclusively in seated subjects performing target acquisition tasks requiring only the involvement of coordinated eye-head movements. However, activities like walking involve full-body movement and require coordination between lower limbs and the eye-head-trunk complex to achieve stabilized gaze during locomotion. Therefore the first goal of this study was to determine how the multiple, interdependent, full-body sensorimotor gaze stabilization subsystems are functionally coordinated during locomotion. In an earlier study we investigated how alteration in gaze tasking changes full-body locomotor control strategies. Subjects walked on a treadmill and either focused on a central point target or read numeral characters. We measured: temporal parameters of gait, full body sagittal plane segmental kinematics of the head, trunk, thigh, shank and foot, accelerations along the vertical axis at the head and the shank, and the vertical forces acting on the support surface. In comparison to the point target fixation condition, the results of the number reading task showed that compensatory head pitch movements increased, peak head acceleration was reduced and knee flexion at heel-strike was increased. In a more recent study we investigated the

  10. Pump testing - Comparison of factory vs. field test of centrifugal pumps

    International Nuclear Information System (INIS)

    Fehlau, R.

    1992-01-01

    Testing of pumps in situ, i.e., as installed in a system, will typically yield somewhat different performance results from the original manufacturer's factory test. This paper discusses some of the reasons for these variations. It shows that the factory test curves can be used for evaluation of initial acceptance tests but not for reference in normal inservice testing (IST). This is the basis for reference values used in American Society of Mechanical Engineers (ASME) Section 11 specifications and the revised ASME Code 1990

  11. Management and Use of Director, Operational Test and Evaluation Funds

    National Research Council Canada - National Science Library

    2000-01-01

    ... and transferred a wide range of test and evaluation functions and resources, including the oversight of the test ranges and facilities, test investment, and sponsorship of many test related programs...

  12. Estimation of the level of anxiety in rats: differences in results of open-field test, elevated plus-maze test, and Vogel's conflict test.

    Science.gov (United States)

    Sudakov, S K; Nazarova, G A; Alekseeva, E V; Bashkatova, V G

    2013-07-01

    We compared individual anxiety assessed by three standard tests, open-field test, elevated plus-maze test, and Vogel conflict drinking test, in the same animals. No significant correlations between the main anxiety parameters were found in these three experimental models. Groups of animals with high and low anxiety rats were formed by a single parameter and subsequent selection of two extreme groups (10%). It was found that none of the tests could be used for reliable estimation of individual anxiety in rats. The individual anxiety level with high degree of confidence was determined in high-anxiety and low-anxiety rats demonstrating behavioral parameters above and below the mean values in all tests used. Therefore, several tests should be used for evaluation of the individual anxiety or sensitivity to emotional stress.

  13. Evaluation of recent quantitative magnetospheric magnetic field models

    International Nuclear Information System (INIS)

    Walker, R.J.

    1976-01-01

    Recent quantitative magnetospheric field models contain many features not found in earlier models. Magnetopause models which include the effects of the dipole tilt were presented. More realistic models of the tail field include tail currents which close on the magnetopause, cross-tail currents of finite thickness, and cross-tail current models which model the position of the neutral sheet as a function of tilt. Finally, models have attempted to calculate the field of currents distributed in the inner magnetosphere. As the purpose of a magnetospheric model is to provide a mathematical description of the field that reasonably reproduces the observed magnetospheric field, several recent models were compared with the observed ΔB(B/sub observed/--B/sub main field/) contours. Models containing only contributions from magnetopause and tail current systems are able to reproduce the observed quiet time field only in an extremely qualitative way. The best quantitative agreement between models and observations occurs when currents distributed in the inner magnetosphere are added to the magnetopause and tail current systems. However, the distributed current models are valid only for zero tilt. Even the models which reproduce the average observed field reasonably well may not give physically reasonable field gradients. Three of the models evaluated contain regions in the near tail in which the field gradient reverses direction. One region in which all the models fall short is that around the polar cusp, though most can be used to calculate the position of the last closed field line reasonably well

  14. Testing and evaluation of high temperature superconductor current leads

    International Nuclear Information System (INIS)

    Yadav, Anand; Puntambekar, Avinash; Manekar, M.A.

    2009-01-01

    National Institute for Inter-disciplinary Science and Technology (NIIST), Council of Scientific and Industrial Research, Trivandrum (formerly Regional Research Laboratory) has accomplished a DAE-BRNS project with Raja Ramanna Centre for Advanced Technology (RRCAT) as principal collaborator for the development of high temperature superconductor (HTS) current leads. These HTS current leads have self-field critical currents (Ic) ranging from 50 A to 1000 A at liquid nitrogen (LN 2 ) temperature. These HTS are made out of silver sheathed Bismuth Strontium Calcium Copper Oxide (BSCCO-2223), for direct application in superconducting (SC) systems involving transportation of high electric currents from power sources at room temperature to superconducting devices at cryogenic temperatures. RRCAT has participated in this project by testing and evaluation of these HTS current leads and carried out actual load trials. In this paper, we will describe the HTS testing setup, tests performed with their testing procedure and the test results. The testing of these HTS has been done with joint effort of Materials Advanced Accelerator Science and Cryogenics Div. and Superconducting Technology Lab (SCT Lab), Advanced Accelerator Module Development Div., using the test facility available at the SCT Lab. (author)

  15. Analysis of results obtained from field tracing test under natural rain condition

    International Nuclear Information System (INIS)

    Mukai, M.; Kamiyama, H.; Tanaka, T.; Wang Zhiming; Zhao Yingjie; Li Zhengtang

    1993-01-01

    As one of the tests arranged by the cooperative research between CIRP and JAERI, field tracing tests using 3 H, 60 Co, 85 Sr and 134 Cs were conducted in pits at the CIRP's field test site located on a loess tableland under natural rain condition. Precipitation amount and evaporation rate were measured to study complicated spatial-temporal behavior of soil water movement under that condition. The evaporation rate was obtained through an analysis on the measured data by a combined method of heat balance and eddy correlation. Numerical model, that is based on piston flow assumption of soil water movement, was developed and applied to determine the behavior of the soil water movement in the pits. Using the determined water movement, 3 H migration was evaluated by numerical simulation. Change of 3 H distribution as a function of elapsed time as well explained by careful evaluation of the soil water movement that carried out before the analysis. (5 figs.)

  16. Evaluation of geostatistical parameters based on well tests; Estimation de parametres geostatistiques a partir de tests de puits

    Energy Technology Data Exchange (ETDEWEB)

    Gauthier, Y.

    1997-10-20

    Geostatistical tools are increasingly used to model permeability fields in subsurface reservoirs, which are considered as a particular random variable development depending of several geostatistical parameters such as variance and correlation length. The first part of the thesis is devoted to the study of relations existing between the transient well pressure (the well test) and the stochastic permeability field, using the apparent permeability concept.The well test performs a moving permeability average over larger and larger volume with increasing time. In the second part, the geostatistical parameters are evaluated using well test data; a Bayesian framework is used and parameters are estimated using the maximum likelihood principle by maximizing the well test data probability density function with respect to these parameters. This method, involving a well test fast evaluation, provides an estimation of the correlation length and the variance over different realizations of a two-dimensional permeability field

  17. Injection grout for deep repositories - Low-pH cementitious grout for larger fractures. Field testing in Finland, Pilot tests

    International Nuclear Information System (INIS)

    Sievaeen, U.; Syrjaenen, P.; Ranta-aho, S.

    2005-10-01

    Posiva, SKB and NUMO have cooperated for developing a low pH injection grout for sealing of the deep repositories for spent nuclear fuel. A project 'Injection grout for deep repositories' was divided into four subprojects. The development of low pH cementitious grout for > 100 μm fractures was carried out in Finland. The development of non-cementitious low pH grout for < 100 μm fractures was carried out in Sweden. This report concerns the cementitious grout. Requirements for pH and penetration ability were set for the grouts to be developed. Besides these, the grouts were desired to fulfil certain targets set for viscosity, bleeding, shear strength, yield value, compressive strength and open time. Also durability, availability of the components and known history in practical engineering were given as requirements. The object of the work presented here was to test if the grout properties developed in laboratory can be met in field conditions. Only the most promising binder material combinations, which have fulfilled the main requirements in laboratory, were tested in field. Evaluations of environmental aspects are included in this report. In the pilot test 1, carried out in a multi-purpose tunnel in Helsinki, Portland cement-cilicasystem and blast furnace slag-based system were chosen to be tested. In field conditions, mixed with ordinary mixer, all grout properties achieved in laboratory, were not verified. Penetration ability was typically good, but fluidity and strength development were not satisfying. The main conclusion was that water to dry material ratio should be diminished. In order to get better rheological properties at the same time, superplastizicer was needed in further development of the mixes. Also accurate dosing and mixing seemed to be very important. Blast furnace slag - system was after this pilot test ruled out due to high leaching of sulphide from the product, not due to the bad technical properties. The development work continued with

  18. 40 CFR 1065.935 - Emission test sequence for field testing.

    Science.gov (United States)

    2010-07-01

    ... value for the previous 2 min or until an engine thermostat controls engine temperature with coolant or... media, such as evacuated bags or tare-weighed PM sample media. (2) Operate the PEMS according to the... ambient data, and integrate measured values using a PEMS. (3) If engine starting is part of field testing...

  19. Field measurement of albedo for limited extent test surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Sailor, David J. [Portland State University, Department of Mechanical and Materials Engineering, P.O. Box 751-ME, Portland, OR 97207 (United States); Resh, Kyle; Segura, Del [Tulane University, Department of Mechanical Engineering, 400 Lindy Boggs Center, New Orleans, LA 70118 (United States)

    2006-05-15

    A new method is introduced for field measurement of surface albedo. This method consists of the use of a cylindrical shade ring made of opaque fabric with a known (low) albedo placed over a test surface. The albedo measurement is accomplished using two small pyranometers situated so that the downward-facing pyranometer receives radiation only from the test surface and the shade ring. The upward-facing pyranometer simultaneously records the incoming solar radiation. The radiation received by the downward-facing pyramometer is a combination of reflected radiation from shaded and unshaded portions of these two surfaces, requiring detailed accounting of the resulting view factor geometries. The method presented here improves upon past approaches by allowing for smaller sample sizes, minimizing errors associated with reflective properties of the surroundings, and allowing for accurate measurements even under partially cloudy skies. In addition to these methodological improvements we introduce an approach for estimating the uncertainty in the resulting albedo measurements. Results from field measurements are presented to validate the measurement protocol, and to compare its accuracy with the accuracy of a published standard. (author)

  20. Additional patient outcomes and pathways in evaluations of testing

    NARCIS (Netherlands)

    Bossuyt, Patrick M. M.; McCaffery, Kirsten

    2009-01-01

    Before medical tests are introduced into practice, they should be properly evaluated. Randomized trials and other comprehensive evaluations of tests and test strategies can best be designed based on an understanding of how tests can benefit or harm patients. Tests primarily affect patients' health

  1. Field test of hydrogen in the natural gas grid

    Energy Technology Data Exchange (ETDEWEB)

    Iskov, H

    2010-08-15

    In order to prepare for a future use of hydrogen as a fuel gas it became evident that very little information existed regarding the compatibility between long-term exposure and transportation of hydrogen in natural gas pipelines. A program was therefore set to study the transportation in a small-scale pilot grid at the research centre in Hoersholm, Denmark. The test program included steel pipes from the Danish gas transmission grid and polymer pipes from the Danish and Swedish gas distribution grid. The test of polymer pipes was devised so that samples of all test pipes were cut out of the grid each year and analysis performed on these pipe samples; in this way any form of influence on the integrity of the polyethylene pipe would be detected. The analytical program for polymer was devised in order to detect any influence on the additivation of the polyethylene as this has an influence on oxidative resistance, as well as checking already encountered possible degradation caused by extrusion of the material. Further tools as rheology and melt flow rate were used for detecting any structural changes on the material. On the mechanical property side the tensile strength and modulus were followed as well as the most important property for the pipe line, namely slow crack growth. The results of the polymer pipe tests show no degradations of any kind related to the continuous hydrogen exposure for more than 4 years. This is a strong indication of the compatibility to hydrogen of the tested polymer materials PE 80 and PE 100. The object of the steel pipe test was to see the effect on fatigue life of existing natural gas transmission lines with hydrogen replacing the natural gas. Full-scale dynamic tests were performed using randomly selected cut-out API 5L X70 pipe sections with a diameter of 20 inches and a wall thickness of 7 millimetres from the Danish natural gas transmission system. The pipe sections contained field girth weld made during the installation of the pipe

  2. Field test of hydrogen in the natural gas grid

    Energy Technology Data Exchange (ETDEWEB)

    Iskov, H.

    2010-08-15

    In order to prepare for a future use of hydrogen as a fuel gas it became evident that very little information existed regarding the compatibility between long-term exposure and transportation of hydrogen in natural gas pipelines. A program was therefore set to study the transportation in a small-scale pilot grid at the research centre in Hoersholm, Denmark. The test program included steel pipes from the Danish gas transmission grid and polymer pipes from the Danish and Swedish gas distribution grid. The test of polymer pipes was devised so that samples of all test pipes were cut out of the grid each year and analysis performed on these pipe samples; in this way any form of influence on the integrity of the polyethylene pipe would be detected. The analytical program for polymer was devised in order to detect any influence on the additivation of the polyethylene as this has an influence on oxidative resistance, as well as checking already encountered possible degradation caused by extrusion of the material. Further tools as rheology and melt flow rate were used for detecting any structural changes on the material. On the mechanical property side the tensile strength and modulus were followed as well as the most important property for the pipe line, namely slow crack growth. The results of the polymer pipe tests show no degradations of any kind related to the continuous hydrogen exposure for more than 4 years. This is a strong indication of the compatibility to hydrogen of the tested polymer materials PE 80 and PE 100. The object of the steel pipe test was to see the effect on fatigue life of existing natural gas transmission lines with hydrogen replacing the natural gas. Full-scale dynamic tests were performed using randomly selected cut-out API 5L X70 pipe sections with a diameter of 20 inches and a wall thickness of 7 millimetres from the Danish natural gas transmission system. The pipe sections contained field girth weld made during the installation of the pipe

  3. Field Testing of Compartmentalization Methods for Multifamily Construction

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States); Lstiburek, J. [Building Science Corporation, Westford, MA (United States)

    2015-03-01

    The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single-family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, driving the need for easier and more effective methods of compartmentalization in multifamily buildings. Builders and practitioners have found that fire-resistance rated wall assemblies are a major source of difficulty in air sealing/compartmentalization, particularly in townhouse construction. This problem is exacerbated when garages are “tucked in” to the units and living space is located over the garages. In this project, Building Science Corporation examined the taping of exterior sheathing details to improve air sealing results in townhouse and multifamily construction, when coupled with a better understanding of air leakage pathways. Current approaches are cumbersome, expensive, time consuming, and ineffective; these details were proposed as a more effective and efficient method. The effectiveness of these air sealing methods was tested with blower door testing, including “nulled” or “guarded” testing (adjacent units run at equal test pressure to null out inter-unit air leakage, or “pressure neutralization”). Pressure diagnostics were used to evaluate unit-to-unit connections and series leakage pathways (i.e., air leakage from exterior, into the fire-resistance rated wall assembly, and to the interior).

  4. Integrated Test and Evaluation (ITE) Flight Test Series 4

    Science.gov (United States)

    Marston, Michael

    2016-01-01

    The integrated Flight Test 4 (FT4) will gather data for the UAS researchers Sense and Avoid systems (referred to as Detect and Avoid in the RTCA SC 228 ToR) algorithms and pilot displays for candidate UAS systems in a relevant environment. The technical goals of FT4 are to: 1) perform end-to-end traffic encounter test of pilot guidance generated by DAA algorithms; 2) collect data to inform the initial Minimum Operational Performance Standards (MOPS) for Detect and Avoid systems. FT4 objectives and test infrastructure builds from previous UAS project simulations and flight tests. NASA Ames (ARC), NASA Armstrong (AFRC), and NASA Langley (LaRC) Research Centers will share responsibility for conducting the tests, each providing a test lab and critical functionality. UAS-NAS project support and participation on the 2014 flight test of ACAS Xu and DAA Self Separation (SS) significantly contributed to building up infrastructure and procedures for FT3 as well. The DAA Scripted flight test (FT4) will be conducted out of NASA Armstrong over an eight-week period beginning in April 2016.

  5. A retrospective evaluation of proficiency testing, and rapid HIV test ...

    African Journals Online (AJOL)

    Background: Proficiency testing (PT) has been implemented as a form of External Quality Assurance (EQA) by the National HIV Reference Laboratory in Kenya since 2007 in order to monitor and improve on the quality of HIV testing and counselling HTC services. Objective: To compare concordance between National HIV ...

  6. Test and evaluation capabilities at NAVELEXCEN Charleston

    Energy Technology Data Exchange (ETDEWEB)

    Stalvey, T.W.; Anderson, G.B.; Hinson, T.L. [Naval Electronic Systems Engineering Center, Charleston, SC (United States)

    1993-12-31

    The Environmental Systems and Instrumentation Engineering Department is located within the Special Programs Directorate of the Naval Electronic Systems Engineering Center (NAVELEXCEN Charleston). This Center is an echelon 4 Command under the Naval Command Control and Ocean Surveillance Center, San Diego (NCCOSC). NCCOSC is an echelon 3 Command under the Space and Warfare Systems Command (SPAWAR) which is located in Washington DC. Radiation Detection, Indication and Computation (RDIAC) equipment life-cycle management for the entire Navy falls under the auspices of the Naval Sea Systems Command (SEA 04R). The RADIAC Program provides centralized management for the execution of research, development, test, evaluation, maintenance, procurement, allowance, and equipment support for all Navy RADIAC instrumentation and assigned special monitoring equipments. RADIAC equipment is used throughout the Navy to support various functions associated with radioactivity, potential contamination, and personnel exposure to sources of ionizing radiation. Common sources in today`s Navy include nuclear reactors, nuclear weapons, industrial radiography, and nuclear medicine. Types of radiation includes gamma, x-ray, alpha, and beta.

  7. Field test investigation of high sensitivity fiber optic seismic geophone

    Science.gov (United States)

    Wang, Meng; Min, Li; Zhang, Xiaolei; Zhang, Faxiang; Sun, Zhihui; Li, Shujuan; Wang, Chang; Zhao, Zhong; Hao, Guanghu

    2017-10-01

    Seismic reflection, whose measured signal is the artificial seismic waves ,is the most effective method and widely used in the geophysical prospecting. And this method can be used for exploration of oil, gas and coal. When a seismic wave travelling through the Earth encounters an interface between two materials with different acoustic impedances, some of the wave energy will reflect off the interface and some will refract through the interface. At its most basic, the seismic reflection technique consists of generating seismic waves and measuring the time taken for the waves to travel from the source, reflect off an interface and be detected by an array of geophones at the surface. Compared to traditional geophones such as electric, magnetic, mechanical and gas geophone, optical fiber geophones have many advantages. Optical fiber geophones can achieve sensing and signal transmission simultaneously. With the development of fiber grating sensor technology, fiber bragg grating (FBG) is being applied in seismic exploration and draws more and more attention to its advantage of anti-electromagnetic interference, high sensitivity and insensitivity to meteorological conditions. In this paper, we designed a high sensitivity geophone and tested its sensitivity, based on the theory of FBG sensing. The frequency response range is from 10 Hz to 100 Hz and the acceleration of the fiber optic seismic geophone is over 1000pm/g. sixteen-element fiber optic seismic geophone array system is presented and the field test is performed in Shengli oilfield of China. The field test shows that: (1) the fiber optic seismic geophone has a higher sensitivity than the traditional geophone between 1-100 Hz;(2) The low frequency reflection wave continuity of fiber Bragg grating geophone is better.

  8. Evaluation of a rapid immunodiagnostic test kit for rabies virus.

    Science.gov (United States)

    Kang, BoKyu; Oh, JinSik; Lee, ChulSeung; Park, Bong-Kyun; Park, YoungNam; Hong, KyungSoo; Lee, KyungGi; Cho, ByungKi; Song, DaeSub

    2007-10-01

    A rapid immunodiagnostic test kit for rabies virus detection was evaluated using 51 clinical samples and 4 isolates of rabies virus. The quick detection of rabies virus under field conditions may be helpful in determining if post-exposure prophylaxis is needed, thereby avoiding unnecessary treatments, as well as undue economic burden. There are several widely used diagnostic methods for rabies, including fluorescent antibody tests, reverse transcription polymerase chain reaction, and electron microscopy; however, these methods include time-consuming, intricate, and costly procedures. The rapid immunodiagnostic test was able to detect rabies virus in clinical samples, including brain tissue and saliva, in addition to 10(3.2) 50% lethal dose (LD(50))/mL cell-adapted rabies virus. The assay was not cross-reactive with non-rabies virus microbes. When the performance of the rapid immunodiagnostic test was compared to a fluorescent antibody test, the rapid immunodiagnostic test had a sensitivity of 91.7% and specificity of 100% (95.8% CI).

  9. Solar cooker effect test and temperature field simulation of radio telescope subreflector

    International Nuclear Information System (INIS)

    Chen, Deshen; Wang, Huajie; Qian, Hongliang; Zhang, Gang; Shen, Shizhao

    2016-01-01

    Highlights: • Solar cooker effect test of a telescope subreflector is conducted for the first time. • The cause and temperature distribution regularities are analyzed contrastively. • Simulation methods are proposed using light beam segmentation and tracking methods. • The validity of simulation methods is evaluated using the test results. - Abstract: The solar cooker effect can cause a local high temperature of the subreflector and can directly affect the working performance of the radio telescope. To study the daily temperature field and solar cooker effect of a subreflector, experimental studies are carried out with a 3-m-diameter radio telescope model for the first time. Initially, the solar temperature distribution rules, especially the solar cooker effect, are summarized according to the field test results under the most unfavorable conditions. Then, a numerical simulation for the solar temperature field of the subreflector is studied by light beam segmentation and tracking methods. Finally, the validity of the simulation methods is evaluated using the test results. The experimental studies prove that the solar cooker effect really exists and should not be overlooked. In addition, simulation methods for the subreflector temperature field proposed in this paper are effective. The research methods and conclusions can provide valuable references for thermal design, monitoring and control of similar high-precision radio telescopes.

  10. Antioxidant effects of nerolidol in mice hippocampus after open field test.

    Science.gov (United States)

    Nogueira Neto, José Damasceno; de Almeida, Antonia Amanda Cardoso; da Silva Oliveira, Johanssy; Dos Santos, Pauline Sousa; de Sousa, Damião Pergentino; de Freitas, Rivelilson Mendes

    2013-09-01

    The aim of this study was to evaluate the neuroprotective effects of nerolidol in mice hippocampus against oxidative stress in neuronal cells compared to ascorbic acid (positive control) as well as evaluated the nerolidol sedative effects by open field test compared to diazepam (positive control). Thirty minutes prior to behavioral observation on open field test, mice were intraperitoneally treated with vehicle, nerolidol (25, 50 and 75 mg/kg), diazepam (1 mg/kg) or ascorbic acid (250 mg/kg). To clarify the action mechanism of of nerolidol on oxidative stress in animals subjected to the open field test, Western blot analysis of Mn-superoxide dismutase and catalase in mice hippocampus were performed. In nerolidol group, there was a significant decrease in lipid peroxidation and nitrite levels when compared to negative control (vehicle). However, a significant increase was observed in superoxide dismutase and catalase activities in this group when compared to the other groups. Vehicle, diazepam, ascorbic acid and nerolidol groups did not affected Mn-superoxide dismutase, catalase mRNA or protein levels. Our findings strongly support the hypothesis that oxidative stress occurs in hippocampus. Nerolidol showed sedative effects in animals subjected to the open field test. Oxidative process plays a crucial role on neuronal pathological consequence, and implies that antioxidant effects could be achieved using this sesquiterpene.

  11. The Savannah River Environmental Technology Field Test Platform: Phase 2

    International Nuclear Information System (INIS)

    Rossabi, J.; Riha, B.D.; Eddy-Dilek, C.A.; Pemberton, B.E.; May, C.P.; Jarosch, T.R.; Looney, B.B.; Raymond, R.

    1995-01-01

    The principal goal in the development of new technologies for environmental monitoring and characterization is transferring them to organizations and individuals for use in site assessment and compliance monitoring. The DOE complex has devised several strategies to facilitate this transfer including joint research projects between private industries and government laboratories or universities (CRADAs) and streamlined licensing procedures. One strategy that has been under-utilized is a planned sequence gradually moving from laboratory development and field demonstration to long term evaluation and onsite use. Industrial partnership and commercial production can be initiated at any step based on the performance, market, user needs, and costs associated with the technology. This approach allows use of the technology by onsite groups for compliance monitoring tasks (e.g. Environmental Restoration and Waste Management), while following parallel research and development organizations the opportunity to evaluate the long term performance and to make modifications or improvements to the technology. This probationary period also provides regulatory organizations, potential industrial partners, and potential users with the opportunity to evaluate the technology's performance and its utility for implementation in environmental characterization and monitoring programs

  12. fields

    Directory of Open Access Journals (Sweden)

    Brad J. Arnold

    2014-07-01

    Full Text Available Surface irrigation, such as flood or furrow, is the predominant form of irrigation in California for agronomic crops. Compared to other irrigation methods, however, it is inefficient in terms of water use; large quantities of water, instead of being used for crop production, are lost to excess deep percolation and tail runoff. In surface-irrigated fields, irrigators commonly cut off the inflow of water when the water advance reaches a familiar or convenient location downfield, but this experience-based strategy has not been very successful in reducing the tail runoff water. Our study compared conventional cutoff practices to a retroactively applied model-based cutoff method in four commercially producing alfalfa fields in Northern California, and evaluated the model using a simple sensor system for practical application in typical alfalfa fields. These field tests illustrated that the model can be used to reduce tail runoff in typical surface-irrigated fields, and using it with a wireless sensor system saves time and labor as well as water.

  13. Cooperative field test program for wind systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bollmeier, W.S. II; Dodge, D.M.

    1992-03-01

    The objectives of the Federal Wind Energy Program, managed by the US Department of Energy (DOE), are (1) to assist industry and utilities in achieving a multi-regional US market penetration of wind systems, and (2) to establish the United States as the world leader in the development of advanced wind turbine technology. In 1984, the program conducted a series of planning workshops with representatives from the wind energy industry to obtain input on the Five-Year Research Plan then being prepared by DOE. One specific suggestion that came out of these meetings was that the federal program should conduct cooperative research tests with industry to enhance the technology transfer process. It was also felt that the active involvement of industry in DOE-funded research would improve the state of the art of wind turbine technology. DOE established the Cooperative Field Test Program (CFTP) in response to that suggestion. This program was one of the first in DOE to feature joint industry-government research test teams working toward common objectives.

  14. Field Evaluation of Advances in Energy-Efficiency Practices for Manufactured Homes

    Energy Technology Data Exchange (ETDEWEB)

    Levy, E. [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Dentz, J. [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Ansanelli, E. [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Barker, G. [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Rath, P. [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Dadia, D. [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States)

    2016-03-01

    Through field-testing and analysis, this project evaluated whole-building approaches and estimated the relative contributions of select technologies toward reducing energy use related to space conditioning in new manufactured homes. Three lab houses of varying designs were built and tested side-by-side under controlled conditions in Russellville, Alabama. The tests provided a valuable indicator of how changes in the construction of manufactured homes can contribute to significant reductions in energy use.

  15. BENCHMARKING MOBILE LASER SCANNING SYSTEMS USING A PERMANENT TEST FIELD

    Directory of Open Access Journals (Sweden)

    H. Kaartinen

    2012-07-01

    Full Text Available The objective of the study was to benchmark the geometric accuracy of mobile laser scanning (MLS systems using a permanent test field under good coverage of GNSS. Mobile laser scanning, also called mobile terrestrial laser scanning, is currently a rapidly developing area in laser scanning where laser scanners, GNSS and IMU are mounted onboard a moving vehicle. MLS can be considered to fill the gap between airborne and terrestrial laser scanning. Data provided by MLS systems can be characterized with the following technical parameters: a point density in the range of 100-1000 points per m2 at 10 m distance, b distance measurement accuracy of 2-5 cm, and c operational scanning range from 1 to 100 m. Several commercial, including e.g. Riegl, Optech and others, and some research mobile laser scanning systems surveyed the test field using predefined driving speed and directions. The acquired georeferenced point clouds were delivered for analyzing. The geometric accuracy of the point clouds was determined using the reference targets that could be identified and measured from the point cloud. Results show that in good GNSS conditions most systems can reach an accuracy of 2 cm both in plane and elevation. The accuracy of a low cost system, the price of which is less than tenth of the other systems, seems to be within a few centimetres at least in ground elevation determination. Inaccuracies in the relative orientation of the instruments lead to systematic errors and when several scanners are used, in multiple reproductions of the objects. Mobile laser scanning systems can collect high density point cloud data with high accuracy. A permanent test field suits well for verifying and comparing the performance of different mobile laser scanning systems. The accuracy of the relative orientation between the mapping instruments needs more attention. For example, if the object is seen double in the point cloud due to imperfect boresight calibration between two

  16. Numerical evaluation of the tensor bispectrum in two field inflation

    Energy Technology Data Exchange (ETDEWEB)

    Raveendran, Rathul Nath [The Institute of Mathematical Sciences, HBNI, CIT Campus, Chennai, 600113 India (India); Sriramkumar, L., E-mail: rathulnr@imsc.res.in, E-mail: sriram@physics.iitm.ac.in [Department of Physics, Indian Institute of Technology Madras, Chennai, 600036 India (India)

    2017-07-01

    We evaluate the dimensionless non-Gaussianity parameter h {sub NL}, that characterizes the amplitude of the tensor bispectrum, numerically for a class of two field inflationary models such as double inflation, hybrid inflation and aligned natural inflation. We compare the numerical results with the slow roll results which can be obtained analytically. In the context of double inflation, we also investigate the effects on h {sub NL} due to curved trajectories in the field space. We explicitly examine the validity of the consistency relation governing the tensor bispectrum in the squeezed limit. Lastly, we discuss the contribution to h {sub NL} due to the epoch of preheating in two field models.

  17. Numerical evaluation of the tensor bispectrum in two field inflation

    International Nuclear Information System (INIS)

    Raveendran, Rathul Nath; Sriramkumar, L.

    2017-01-01

    We evaluate the dimensionless non-Gaussianity parameter h NL , that characterizes the amplitude of the tensor bispectrum, numerically for a class of two field inflationary models such as double inflation, hybrid inflation and aligned natural inflation. We compare the numerical results with the slow roll results which can be obtained analytically. In the context of double inflation, we also investigate the effects on h NL due to curved trajectories in the field space. We explicitly examine the validity of the consistency relation governing the tensor bispectrum in the squeezed limit. Lastly, we discuss the contribution to h NL due to the epoch of preheating in two field models.

  18. Field evaluation of hazardous waste site bioassessment protocols

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, J.M.; Cline, J.F.; Cushing, C.E.; McShane, M.C.; Rogers, J.E.; Rogers, L.E.; Simpson, J.C.; Skalski, J.R.

    1983-04-01

    The goals were: (1) determine the variability (both within and between laboratories) for the various bioassay procedures using contaminated soil samples from the Rocky Mountain Arsenal (RMA); (2) assess variability within and between plots for several assessment techniques (for sampling small mammals, plants, insects including honeybees and microarthropods) so that field studies could be designed to detect a defined biotic change; (3) establish three field plant transects which are apparently (a) contaminated, (b) appear contaminated and (c) could serve as a control; (4) assess the feasibility (in the laboratory) of using Basin F water to contaminate RMA soil artificially, and to supply information for the design of a field plot study in 1983; (5) attempt to obtain preliminary data on any promising field or laboratory bioassessment techniques not currently mentioned in the statement of work; and (6) obtain field data to assess the ecological status of RMA lakes and compare these observations to results from bioassessment testing.

  19. FAID/SPAR field tests at Kahl: A final report

    International Nuclear Information System (INIS)

    McKenzie, J.M.; Self, B.G.; Crawford, T.J.; Suber, L.A.

    1986-01-01

    LWR fuel assemblies are convenient units for item accounting. A pplication of a fuel assembly seal which gives both integrity and a unique identity to the fuel assembly offers the potential of increased safeguards over present methods. This is particularly the case if the seal can be read at frequent intervals. The BWR Kahl reactor has been used to field evaluate FAID type ultrasonic seals. Twenty-four seals were applied to fresh fuel assemblies before their being placed in the reactor core. At convenient times when the reactor was shut down and the fuel moved to the spent fuel storage pool, the seal's identity and integrity were checked with a seal pattern reader (SPAR). After the reactor was decommissioned all seals were reidentified and their integrity checked. Five seals were removed from their fuel assemblies and embrittlement of the fracture link observed. Several seals were in the reactor core for three years

  20. Results of field testing of radioactive waste forms using lysimeters

    International Nuclear Information System (INIS)

    McConnell, J.W., Jr.; Rogers, R.D.; Jastrow, J.D.; Wickliff, D.S.

    1992-01-01

    The Field Lysimeter Investigation: Low-Level Waste Data Base Development Program is obtaining informaiton on the performance of radioactive waste in a disposal environment. Waste forms fabricated using ion-exchange resins from EPICOR-II prefilters employed in the cleanup of the Three Mile Island (TMI) Nuclear Power Station are being tested to develop a low-level waste data base and to obtain information on survivability of waste forms in a disposal environment. In this paper, radionuclide releases from waste forms in the first six years of sampling are presented and discussed. Application of lysimeter data to use in performance assessment models is presented. Initial results from use of data in a performance assessment model are discussed

  1. Field Tested Service Oriented Robotic Architecture: Case Study

    Science.gov (United States)

    Flueckiger, Lorenzo; Utz, Hanz

    2012-01-01

    This paper presents the lessons learned from six years of experiments with planetary rover prototypes running the Service Oriented Robotic Architecture (SORA) developed by the Intelligent Robotics Group (IRG) at NASA Ames Research Center. SORA relies on proven software methods and technologies applied to the robotic world. Based on a Service Oriented Architecture and robust middleware, SORA extends its reach beyond the on-board robot controller and supports the full suite of software tools used during mission scenarios from ground control to remote robotic sites. SORA has been field tested in numerous scenarios of robotic lunar and planetary exploration. The results of these high fidelity experiments are illustrated through concrete examples that have shown the benefits of using SORA as well as its limitations.

  2. The passive hamstring stretch test: clinical evaluation.

    Science.gov (United States)

    Fisk, J W

    1979-03-28

    The passive hamstring stretch test is described. Using a modified goniometer it is shown that independent measurements taken by trained examiners approximate very closely to each other. This establishes the test as a valid objective measurement. The possible value of this test as a research tool in low back pain problems is discussed.

  3. Near-field modeling in Frenchman Flat, Nevada Test Site

    International Nuclear Information System (INIS)

    Pohlmann, K.; Shirley, C.; Andricevic, R.

    1996-12-01

    The US Department of Energy (DOE) is investigating the effects of nuclear testing in underground test areas (the UGTA program) at the Nevada Test Site. The principal focus of the UGTA program is to better understand and define subsurface radionuclide migration. The study described in this report focuses on the development of tools for generating maps of hydrogeologic characteristics of subsurface Tertiary volcanic units at the Frenchman Flat corrective Action Unit (CAU). The process includes three steps. The first step involves generation of three-dimensional maps of the geologic structure of subsurface volcanic units using geophysical logs to distinguish between two classes: densely welded tuff and nonwelded tuff. The second step generates three-dimensional maps of hydraulic conductivity utilizing the spatial distribution of the two geologic classes obtained in the first step. Each class is described by a correlation structure based on existing data on hydraulic conductivity, and conditioned on the generated spatial location of each class. The final step demonstrates the use of the maps of hydraulic conductivity for modeling groundwater flow and radionuclide transport in volcanic tuffs from an underground nuclear test at the Frenchman Flat CAU. The results indicate that the majority of groundwater flow through the volcanic section occurs through zones of densely welded tuff where connected fractures provide the transport pathway. Migration rates range between near zero to approximately four m/yr, with a mean rate of 0.68 m/yr. This report presents the results of work under the FY96 Near-Field Modeling task of the UGTA program

  4. Testing neoclassical competitive market theory in the field.

    Science.gov (United States)

    List, John A

    2002-11-26

    This study presents results from a pilot field experiment that tests predictions of competitive market theory. A major advantage of this particular field experimental design is that my laboratory is the marketplace: subjects are engaged in buying, selling, and trading activities whether I run an exchange experiment or am a passive observer. In this sense, I am gathering data in a natural environment while still maintaining the necessary control to execute a clean comparison between treatments. The main results of the study fall into two categories. First, the competitive model predicts reasonably well in some market treatments: the expected price and quantity levels are approximated in many market rounds. Second, the data suggest that market composition is important: buyer and seller experience levels impact not only the distribution of rents but also the overall level of rents captured. An unexpected result in this regard is that average market efficiency is lowest in markets that match experienced buyers and experienced sellers and highest when experienced buyers engage in bargaining with inexperienced sellers. Together, these results suggest that both market experience and market composition play an important role in the equilibrium discovery process.

  5. Results of field testing of waste forms using lysimeters

    International Nuclear Information System (INIS)

    McConnell, J.W. Jr.; Rogers, R.D.

    1988-01-01

    The purpose of the field testing task, using lysimeter arrays, is to expose samples of solidified resin waste to the actual physical, chemical, and microbiological conditions of disposal enviroment. Wastes used in the experiment include a mixture of synthetic organic ion exchange resins and a mixture of organic exchange resins and an inorganic zeolite. Solidification agents used to produce the 4.8-by 7.6-cm cylindrical waste forms used in the study were Portland Type I-II cement and Dow vinyl ester-styrene. Seven of these waste forms were stacked end-to-end and inserted into each lysimeter to provide a 1-L volume. There are 10 lysimeters, 5 at ORNL and 5 at ANL-E. Lysimeters used in this study were designed to be self-contained units which will be disposed at the termination of the 20-year study. Each is a 0.91-by 3.12-m right-circular cylinder divided into an upper compartment, which contains fill material, waste forms, and instrumentation, and an empty lower compartment, which collects leachate. Four lysimeters at each site are filled with soil, while a fifth (used as a control) is filled with inert silica oxide sand. Instrumentation within each lysimeter includes porous cup soil-water samplers and soil moisture/temperature probes. The probes are connected to an on-site data acquisition and storage system (DAS) which also collects data from a field meteorological station located at each site. 9 refs

  6. Flood field uniformity testing - effects of crystal hydration

    International Nuclear Information System (INIS)

    Dimcheva, M.; Sergieva, S.; Doldurova, M.; Jovanovska, A.

    2012-01-01

    The most basic and sensitive routine quality control (QC) of gamma camera is that of intrinsic flood-field uniformity. The routine QC test must be assessed daily and any nonuniformity must be eliminated before patient testing to eliminate artifacts and false positive or false-negative patient results. The purpose of this study was to compare uniformity analysis results for scintillation crystal hydration with symmetric and asymmetric energy window on the Siemens Symbia T2 SPECTCT camera. Integral and differential uniformity analysis was performed by placing a point source 99m Tc in front of the detector with removed collimator to measure the effect of correction matrix, a count rate and activity volume on intrinsic uniformity. A 15% energy window set symmetrically over the 99m Tc photo peak is equivalent to 140±10% keV or a window spanning 126-154 keV. The results, received from Detector 2 gave the following uniformity parameter values: Both asymmetric energy window images show clearly multiple focal spots due to crystal hydration: discrete hot spots in the asymmetric low window image and discrete cold spots in the asymmetric high window image. The above results are not seen yet on the symmetric window image. We had replaced Detector 2 in order to avoid spots become visible in flood images obtained with the clinical energy window. The uniformity of a gamma camera is maybe the most important parameter that expresses the quality of the camera's performance. Non uniform areas in the field of view can result in misdiagnosed patients and low quality of clinical services. (authors)

  7. Evaluating amber force fields using computed NMR chemical shifts.

    Science.gov (United States)

    Koes, David R; Vries, John K

    2017-10-01

    NMR chemical shifts can be computed from molecular dynamics (MD) simulations using a template matching approach and a library of conformers containing chemical shifts generated from ab initio quantum calculations. This approach has potential utility for evaluating the force fields that underlie these simulations. Imperfections in force fields generate flawed atomic coordinates. Chemical shifts obtained from flawed coordinates have errors that can be traced back to these imperfections. We use this approach to evaluate a series of AMBER force fields that have been refined over the course of two decades (ff94, ff96, ff99SB, ff14SB, ff14ipq, and ff15ipq). For each force field a series of MD simulations are carried out for eight model proteins. The calculated chemical shifts for the 1 H, 15 N, and 13 C a atoms are compared with experimental values. Initial evaluations are based on root mean squared (RMS) errors at the protein level. These results are further refined based on secondary structure and the types of atoms involved in nonbonded interactions. The best chemical shift for identifying force field differences is the shift associated with peptide protons. Examination of the model proteins on a residue by residue basis reveals that force field performance is highly dependent on residue position. Examination of the time course of nonbonded interactions at these sites provides explanations for chemical shift differences at the atomic coordinate level. Results show that the newer ff14ipq and ff15ipq force fields developed with the implicitly polarized charge method perform better than the older force fields. © 2017 Wiley Periodicals, Inc.

  8. Technical Evaluation of Oak Ridge Filter Test Facility

    CERN Document Server

    Kriskovich, J R

    2002-01-01

    Two evaluations of the Oak Ridge Department of Energy (DOE) Filter Test Facility (FTF) were performed on December 11 and 12, 2001, and consisted of a quality assurance and a technical evaluation. This report documents results of the technical evaluation.

  9. Advanced Utility Mercury-Sorbent Field-Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Ronald Landreth

    2007-12-31

    This report summarizes the work conducted from September 1, 2003 through December 31, 2007 on the project entitled Advanced Utility Mercury-Sorbent Field-Testing Program. The project covers the testing at the Detroit Edison St. Clair Plant and the Duke Power Cliffside and Buck Stations. The St. Clair Plant used a blend of subbituminous and bituminous coal and controlled the particulate emissions by means of a cold-side ESP. The Duke Power Stations used bituminous coals and controlled their particulate emissions by means of hot-side ESPs. The testing at the Detroit Edison St. Clair Plant demonstrated that mercury sorbents could be used to achieve high mercury removal rates with low injection rates at facilities that burn subbituminous coal. A mercury removal rate of 94% was achieved at an injection rate of 3 lb/MMacf over the thirty day long-term test. Prior to this test, it was believed that the mercury in flue gas of this type would be the most difficult to capture. This is not the case. The testing at the two Duke Power Stations proved that carbon- based mercury sorbents can be used to control the mercury emissions from boilers with hot-side ESPs. It was known that plain PACs did not have any mercury capacity at elevated temperatures but that brominated B-PAC did. The mercury removal rate varies with the operation but it appears that mercury removal rates equal to or greater than 50% are achievable in facilities equipped with hot-side ESPs. As part of the program, both sorbent injection equipment and sorbent production equipment was acquired and operated. This equipment performed very well during this program. In addition, mercury instruments were acquired for this program. These instruments worked well in the flue gas at the St. Clair Plant but not as well in the flue gas at the Duke Power Stations. It is believed that the difference in the amount of oxidized mercury, more at Duke Power, was the difference in instrument performance. Much of the equipment was

  10. [Evaluation of the Freiburg monosyllabic speech test in background noise].

    Science.gov (United States)

    Löhler, J; Akcicek, B; Pilnik, M; Saager-Post, K; Dazert, S; Biedron, S; Oeken, J; Mürbe, D; Löbert, J; Laszig, R; Wesarg, T; Langer, C; Plontke, S; Rahne, T; Machate, U; Noppeney, R; Schultz, K; Plinkert, P; Hoth, S; Praetorius, M; Schlattmann, P; Meister, E F; Pau, H W; Ehrt, K; Hagen, R; Shehata-Dieler, W; Cebulla, M; Walther, L E; Ernst, A

    2013-07-01

    The Freiburg speech test has been the gold standard in speech audiometry in Germany for many years. Previously, however, this test had not been evaluated in assessing the effectiveness of a hearing aid in background noise. Furthermore, the validity of particular word lists used in the test has been questioned repeatedly in the past, due to a suspected higher variation within these lists as compared to the other word list used. In this prospective study, two groups of subjects [normal hearing control subjects and patients with SNHL (sensorineural hearing loss) that had been fitted with hearing aid] were examined. In a first group, 113 control subjects with normal age- and gender-related pure tone thresholds were assessed by means of the Freiburg monosyllabic test under free-field conditions at 65 dB. The second group comprised 104 patients that had been fitted with hearing aids at least 3 months previously to treat their SNHL. Members of the SNHL group were assessed by means of the Freiburg monosyllabic test both with and without hearing aids, and in the presence or absence of background noise (CCITT-noise; 65/60 dB signal-noise ratio, in accordance with the Comité Consultatif International Téléphonique et Télégraphique), under free-field conditions at 65 dB. The first (control) group exhibited no gender-related differences in the Freiburg test results. In a few instances, inter-individual variability of responses was observed, although the reasons for this remain to be clarified. Within the second (patient) group, the Freiburg test results under the four different measurement conditions differed significantly from each other (p>0.05). This group exhibited a high degree of inter-individual variability between responses. In light of this, no significant differences in outcome could be assigned to the different word lists employed in the Freiburg speech test. The Freiburg monosyllabic test is able to assess the extent of hearing loss, as well as the effectiveness

  11. GLM Post Launch Testing and Airborne Science Field Campaign

    Science.gov (United States)

    Goodman, S. J.; Padula, F.; Koshak, W. J.; Blakeslee, R. J.

    2017-12-01

    The Geostationary Operational Environmental Satellite (GOES-R) series provides the continuity for the existing GOES system currently operating over the Western Hemisphere. The Geostationary Lightning Mapper (GLM) is a wholly new instrument that provides a capability for total lightning detection (cloud and cloud-to-ground flashes). The first satellite in the GOES-R series, now GOES-16, was launched in November 2016 followed by in-orbit post launch testing for approximately 12 months before being placed into operations replacing the GOES-E satellite in December. The GLM will map total lightning continuously throughout day and night with near-uniform spatial resolution of 8 km with a product latency of less than 20 sec over the Americas and adjacent oceanic regions. The total lightning is very useful for identifying hazardous and severe thunderstorms, monitoring storm intensification and tracking evolution. Used in tandem with radar, satellite imagery, and surface observations, total lightning data has great potential to increase lead time for severe storm warnings, improve aviation safety and efficiency, and increase public safety. In this paper we present initial results from the post-launch in-orbit performance testing, airborne science field campaign conducted March-May, 2017 and assessments of the GLM instrument and science products.

  12. Niland Test Facility Startup Evaluation Task Force

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-01

    The following team reports are included: systems, operation, control, and safety; instrumentation; brine chemistry and materials evaluation; reservoir assessment; environment; and contingency analysis. (MHR)

  13. The ''INVERSE PROBLEM'' to the evaluation of magnetic fields

    International Nuclear Information System (INIS)

    Caspi, S.; Helm, M.; Laslett, L.J.

    1996-01-01

    In the design of superconducting magnet elements, such as may be required to guide and focus ions in a particle accelerator, one frequently premises some particular current distribution and then proceeds to compute the consequent magnetic field through use of the laws of Biot and Savart or of Ampere. When working in this manner one of course may need to revise frequently the postulated current distribution before arriving at a resulting magnetic field of acceptable field quality. It therefore is of interest to consider an alternative (inverse) procedure in which one specifies a desired character for the field required in the region interior to the winding and undertakes then to evaluate the current distribution on the specified winding surface that would provide this desired field. By evaluating the specified potential in the region interior to the winding along the interface, the authors have determined that a relaxation solution to the potential in the region outside the winding can be converged and used to calculate wire location. They have demonstrated this method by applying a slightly modified version of the program POISSON to a periodic alternating sinusoidal quadrupole field

  14. Test and evaluation of pressure vessel materials

    International Nuclear Information System (INIS)

    Choi, Sun Pil; Hong, Jun Hwa; Nho, Kye Hoe; Han, Dae June; Chi, Se Hwan

    1985-01-01

    We have prepared a method for analyzing the Charpy impact test data, which is deduced from ''the standard anelastic solid equation''. The theoretical expression for the absorbed energy is in a form of W=Wsub(U)+(Wsub(R)-Wsub(U))/ [1+(ωtau) 2 ] showing the Debye characteristics and where tau is given by the Arrhenius equation; tau=tau 0 exp(ΔH/ksub(B)T). Four measurable parameters, at the present stage, can characterize the dynamic hehavior of cracking (Charpy impact result). They are the upper shelf energy(Wsub(R), the lower shelf energy (Wsub(U)), the activation energy of crack (ΔH, and wtau(0) where w tau(0) are the resonance frequency of the specimen and the jumping pre-exponential factor of propagating crack respectively. However the states of R (relaxed) and U (un-relaxed) should be defined from reasonable physical conditions in the future and it is possible that Wsub(U) is small enough to be taken as zero. The effects of irradiation, alloying elements, and heat treatment on the impact results should be interpreted as changes in the above characteristic parameters. The present method has been applied for weld metal of SA 508-2 irradiated up to a fluence of 4x10 18 n/cm 2 , E>1.0Mev, resulting in about 29% decrease in Wsub(R), negligible change in Wsub(U), 5.6 times increase in ωtau 0 , and no change in ΔH. This seems to indicate that irradiation degrades an average value of YOUNG's modulus so that cracks propagate more easily and it does not effect on breaking the lattice bond. However much more systematic analyses should be necessary for correct judgment. It is concluded that the present method is quite adequate for analyzing the Charpy impact data even though plastic deformation in the specimen was not considered separately so that the method should be applied for various cases in order to evaluate the proper trend of effects of irradiation, alloying elements, and heat treatment on the Charpy impact results. (Author)

  15. Field Evaluation of Immunogenicity of Five Commercial Vaccines ...

    African Journals Online (AJOL)

    Field Evaluation of Immunogenicity of Five Commercial Vaccines Against Newcastle Disease in Poultry Farms in Ibadan, Nigeria. ... The PDF file you selected should load here if your Web browser has a PDF reader plug-in installed (for example, a recent version of Adobe Acrobat Reader). If you would like more information ...

  16. A field evaluation of coated urea with biodegradable materials and ...

    African Journals Online (AJOL)

    Urease inhibitor and biodegradable polymer coatings are two most suitable startegies to increase urea fertilizer efficiency. Coating of urea with selected inhibitors can increase the crop production by slowing down the hydrolysis process of urea in the soil. For this purpose, a field experiment was conducted to evaluate the ...

  17. Towards strong field tests of beyond Horndeski gravity theories

    Science.gov (United States)

    Sakstein, Jeremy; Babichev, Eugeny; Koyama, Kazuya; Langlois, David; Saito, Ryo

    2017-03-01

    Theories of gravity in the beyond Horndeski class encompass a wide range of scalar-tensor theories that will be tested on cosmological scales over the coming decade. In this work, we investigate the possibility of testing them in the strong field regime by looking at the properties of compact objects—neutron, hyperon, and quark stars—embedded in an asymptotically de Sitter space-time, for a specific subclass of theories. We extend previous works to include slow rotation and find a relation between the dimensionless moment of inertia (I ¯ =I c2/GNM3 ) and the compactness C =GNM /R c2 (an I ¯-C relation), independent of the equation of state, that is reminiscent of but distinct from the general relativity prediction. Several of our equations of state contain hyperons and free quarks, allowing us to revisit the hyperon puzzle. We find that the maximum mass of hyperon stars can be larger than 2 M⊙ for small values of the beyond Horndeski parameter, thus providing a resolution of the hyperon puzzle based on modified gravity. Moreover, stable quark stars exist when hyperonic stars are unstable, which means that the phase transition from hyperon to quark stars is predicted just as in general relativity (GR), albeit with larger quark star masses. Two important and potentially observable consequences of some of the theories we consider are the existence of neutron stars in a range of masses significantly higher than in GR and I ¯-C relations that differ from their GR counterparts. In the former case, we find objects that, if observed, could not be accounted for in GR because they violate the usual GR causality condition. We end by discussing several difficult technical issues that remain to be addressed in order to reach more realistic predictions that may be tested using gravitational wave searches or neutron star observations.

  18. Development and testing of a thermoluminescent dosemeter for mixed neutron-photon-beta radiation fields

    International Nuclear Information System (INIS)

    Zummo, J.J.; Liu, J.C.

    1998-08-01

    A new four-element thermoluminescent (TL) dosemeter and dose evaluation algorithm have been developed and tested to better characterize personnel exposure in mixed neutron-photon-beta radiation fields. The prototype dosemeter is based on a commercially available TL card (with three LiF-7 chips and one LiF-6 chip) and modified filtration elements. The new algorithm takes advantage of the high temperature peak characteristics of the LiF-6 element to better quantify the neutron dose component. The dosemeter was tested in various radiation fields, consisting of mixtures of two radiation types typically used for dosemeter performance testing, as well as mixtures of three radiation types to simulate possible exposure conditions. The new dosemeter gave superior performance, based on the tolerance levels, when using the new algorithm as compared to a conventional algorithm that did not use the high temperature peak methodology. The limitations and further improvements are discussed

  19. Determination of antenna factors using a three-antenna method at open-field test site

    Science.gov (United States)

    Masuzawa, Hiroshi; Tejima, Teruo; Harima, Katsushige; Morikawa, Takao

    1992-09-01

    Recently NIST has used the three-antenna method for calibration of the antenna factor of an antenna used for EMI measurements. This method does not require the specially designed standard antennas which are necessary in the standard field method or the standard antenna method, and can be used at an open-field test site. This paper theoretically and experimentally examines the measurement errors of this method and evaluates the precision of the antenna-factor calibration. It is found that the main source of the error is the non-ideal propagation characteristics of the test site, which should therefore be measured before the calibration. The precision of the antenna-factor calibration at the test site used in these experiments, is estimated to be 0.5 dB.

  20. 25th Test and Evaluation National Conference

    Science.gov (United States)

    2009-03-05

    assembly area.] • Load Aircraft and Weapon Status Check. • Lineup for takeoff. – Execute Mission [R and A mission executed as requested by ground... sequential testing and the sharing of high-demand testing assets Negative impact on ability to successfully execute complex programs: Massive

  1. Empirical Evaluation of Directional-Dependence Tests

    Science.gov (United States)

    Thoemmes, Felix

    2015-01-01

    Testing of directional dependence is a method to infer causal direction that recently has attracted some attention. Previous examples by e.g. von Eye and DeShon (2012a) and extensive simulation studies by Pornprasertmanit and Little (2012) have demonstrated that under specific assumptions, directional-dependence tests can recover the true causal…

  2. Describing of elements IO field in a testing computer program

    Directory of Open Access Journals (Sweden)

    Igor V. Loshkov

    2017-01-01

    Full Text Available A standard of describing the process of displaying interactive windows on a computer monitor, through which an output of questions and input of answers are implemented during computer testing, is presented in the article [11]. According to the proposed standard, the description of the process mentioned above is performed with a format line, containing element names, their parameters as well as grouping and auxiliary symbols. Program objects are described using elements of standard. The majority of objects create input and output windows on a computer monitor. The aim of our research was to develop a minimum possible set of elements of standard to perform mathematical and computer science testing.The choice of elements of the standard was conducted in parallel with the development and testing of the program that uses them. This approach made it possible to choose a sufficiently complete set of elements for testing in fields of study mentioned above. For the proposed elements, names were selected in such a way: firstly, they indicate their function and secondly, they coincide with the names of elements in other programming languages that are similar by function. Parameters, their names, their assignments and accepted values are proposed for the elements. The principle of name selection for the parameters was the same as for elements of the standard: the names should correspond to their assignments or coincide with names of similar parameters in other programming languages. The parameters define properties of objects. Particularly, while the elements of standard create windows, the parameters define object properties (location, size, appearance and the sequence in which windows are created. All elements of standard, proposed in this article are composed in a table, the columns of which have names and functions of these elements. Inside the table, the elements of standard are grouped row by row into four sets: input elements, output elements, input

  3. Portal monitor evaluation and test procedure

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Rich, B.L.

    1983-10-01

    The purpose was to develop techniques and procedures to allow users to measure performance and sensitivity of portal monitors. Additionally, a methodology was developed to assist users in optimizing monitor performance. The two monitors tested utilized thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: a) background count rate and the statistical variability, b) detector efficiency at different distances, c) moving source sensitivity for various size sources and speeds, and d) false alarm rates at different background levels. A model was developed for the moving source measurements to compare the experimental data with measured results, and to test whether it is possible to adequately model the behavior of a portal monitor's response to a moving source. The model results were compared with the actual test results. A procedure for testing portal monitors is also given. 1 reference, 9 figures, 8 tables

  4. Advanced Rooftop Control (ARC) Retrofit: Field-Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Weimin; Katipamula, Srinivas; Ngo, Hung; Underhill, Ronald M.; Taasevigen, Danny J.; Lutes, Robert G.

    2013-07-31

    The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

  5. A strategy for field shape evaluation in digital portal imaging

    International Nuclear Information System (INIS)

    Vos, P.H.; Quist, M.; Weistra, J.; Vossepoel, A.M.

    1995-01-01

    Digital portal imagers allow accurate measurement of the field shape in radiotherapy. A strategy is introduced to determine origin and magnitude of discrepancies between the prescribed and measured field outline. After measurement of the actual detector position relative to the beam a conversion is made from pixels in the image matrix to mm in the plane of the isocenter, without using information from the imaged field. Using a distance transform a quick check is performed: the outline is accepted if all outline points deviate less then a predefined minimum (usually 5 mm). Subsequent evaluation starts if somewhere in the outline this minimum is exceeded. The collimator defined parts in the field outline are discriminated from the shielding blocks using an enclosing rectangle of the portal outline. This rectangle is found by minimization of the area as a function of rotation. If more than one solution is available, minimization of the entropy of the field outline projections determines which rectangle corresponds best to the field outline. A check for the validity of the determined collimator parts is performed with a separate linear fit through these parts. An outline part is accepted as a collimator outline part if it is longer than a predefined length. Using this procedure the position for each of the collimator jaws can be individually measured and compared with its prescription, thus allowing discrimination between symmetric and asymmetric collimator set-ups. Using the distance transform again, for each of the detected (secondary) shielding blocks the largest discrepancy or the area giving underdosage or overdosage can be computed to evaluate their shape and position. Parameter(s) and criteria that should be used to evaluate the field set-up are specified in clinical protocols. For standard shielding blocks usually only a maximum tolerated difference is specified, whereas for mantle fields also maximum allowed over- and underdose areas are specified. The

  6. Hydrologic modeling and field testing at Yucca mountain, Nevada

    International Nuclear Information System (INIS)

    Hoxie, D.T.

    1991-01-01

    Yucca Mountain, Nevada, is being evaluated as a possible site for a mined geologic repository for the disposal of high-level nuclear waste. The repository is proposed to be constructed in fractured, densely welded tuff within the thick (500 to 750 meters) unsaturated zone at the site. Characterization of the site unsaturated-zone hydrogeologic system requires quantitative specification of the existing state of the system and the development of numerical hydrologic models to predict probable evolution of the hydrogeologic system over the lifetime of the repository. To support development of hydrologic models for the system, a testing program has been designed to characterize the existing state of the system, to measure hydrologic properties for the system and to identify and quantify those processes that control system dynamics. 12 refs

  7. Field-Testing of an Active Laser Tracking System

    Science.gov (United States)

    Markov, V.; Khiznyak, A.; Woll, D.; Liu, S.

    -mirror module for laser beam steering and detectors, all set on a single platform. In the initial ALTS design, the laser module is conceptualized in coupled-cavitiesarchitecturewith a synchronously pumped gain media, a four-wave mixing PCM. The four-wave mixing arrangement uses optical phase conjugation to compensate for spatial inhomogeneities of the atmosphere. A significant innovation in the proposed approach is in its perspective capabilities to detect and measure the critical parameters in the returned signal that should allow to directly measure spatial/angular position and velocity of the target. This report will cover the system analysis, the ALTS design, test plan and exit criteria, functional and operational tests, and test results at Edwards AFB Range field.

  8. Cold test for bean seed vigor evaluation

    OpenAIRE

    Miguel, Marcelo Hissnauer; Cicero, Silvio Moure

    1999-01-01

    O presente trabalho teve como objetivo estudar o comportamento de sementes de feijão submetidas a diferentes metodologias do teste de frio, comparativamente a outros testes de vigor tradicionalmente utilizados na avaliação da qualidade fisiológica dessas sementes. As metodologias do teste de frio utilizadas foram: caixa plástica com terra, rolo de papel com terra e rolo de papel sem terra, nas temperaturas de 10ºC e de 15ºC e períodos de exposição, de três, cinco e sete dias. Paralelamente fo...

  9. Coanda hydro intake screen testing and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Howarth, J.

    2001-07-01

    The objective of this project has been to evaluate the effectiveness, suitability and cost benefit of the Aquashear Coanda effect, maintenance free intake screen for use in small hydro system intakes. (author)

  10. Test report : alternative fuels propulsion durability evaluation

    Science.gov (United States)

    2012-08-28

    This document, prepared by Honeywell Aerospace, Phoenix, AZ (Honeywell), contains the final : test report (public version) for the U.S. Department of Transportation/Federal Aviation : Administration (USDOT/FAA) Alternative Fuels Propulsion Engine Dur...

  11. Integral test on activation cross section of tag gas nuclides using fast neutron spectrum fields

    Energy Technology Data Exchange (ETDEWEB)

    Aoyama, Takafumi; Suzuki, Soju [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1997-03-01

    Activation cross sections of tag gas nuclides, which will be used for the failed fuel detection and location in FBR plants, were evaluated by the irradiation tests in the fast neutron spectrum fields in JOYO and YAYOI. The comparison of their measured radioactivities and the calculated values using the JENDL-3.2 cross section set showed that the C/E values ranged from 0.8 to 2.8 for the calibration tests in YAYOI and that the present accuracies of these cross sections were confirmed. (author)

  12. Validity of selected cardiovascular field-based test among Malaysian ...

    African Journals Online (AJOL)

    Based on emerge obese problem among Malaysian, this research is formulated to validate published tests among healthy female adult. Selected test namely; 20 meter multi-stage shuttle run, 2.4km run test, 1 mile walk test and Harvard Step test were correlated with laboratory test (Bruce protocol) to find the criterion validity ...

  13. Nondestructive Evaluation of Railway Bridge by System Identification Using Field Vibration Measurement

    International Nuclear Information System (INIS)

    Ho, Duc Duy; Hong, Dong Soo; Kim, Jeong Tae

    2010-01-01

    This paper presents a nondestructive evaluation approach for system identification (SID) of real railway bridges using field vibration test results. First, a multi-phase SID scheme designed on the basis of eigenvalue sensitivity concept is presented. Next, the proposed multi-phase approach is evaluated from field vibration tests on a real railway bridge (Wondongcheon bridge) located in Yangsan, Korea. On the steel girder bridge, a few natural frequencies and mode shapes are experimentally measured under the ambient vibration condition. The corresponding modal parameters are numerically calculated from a three-dimensional finite element (FE) model established for the target bridge. Eigenvalue sensitivities are analyzed for potential model-updating parameters of the FE model. Then, structural subsystems are identified phase-by-phase using the proposed model-updating procedure. Based on model-updating results, a baseline model and a nondestructive evaluation of test bridge are identified

  14. SDU6 Interior Liner Testing & Evaluation

    International Nuclear Information System (INIS)

    Skidmore, T. E.

    2016-01-01

    Two liner materials (Marseal® M-3500 and REMA Chemoline® 4CN) proposed for use as a liner inside the Saltstone Disposal Unit 6 (SDU6) were subjected to specific ASTM tests (tensile and lap-shear) after immersion in 50% and 100% simulant solutions for 1000 hours at the Savannah River Ecology Laboratory. Both liner materials exhibited good resistance to the simulant chemistry, at least based on the tests performed and the test duration/conditions imposed. In lap-shear tests, both materials failed in the base material rather than peeling apart, confirming good adhesion. The REMA 4CN bromobutyl elastomer showed superior bonding characteristics and absence of warping or delamination at the conditions tested. The Marseal M-3500 material (PVC/EVA blend with polyester reinforcement) exhibited deformation and debonding in some locations. The cause of the deformation and delamination observed in the Marseal M-3500 material is not fully known, but possibly attributed to thermomechanical stress at immersion temperatures, and the thermoplastic nature of the material. The immersion temperature (68 °C) is slightly greater than the maximum use temperature limit quoted for the Marseal M- 3500 liner (65 °C), though the basis for the service limit is unknown. The testing performed was limited in scope and only for these two liner materials. These tests were primarily performed to screen for severe incompatibility or short-term degradation in Saltstone bleedwater simulants at bounding solution temperatures. Additional testing is recommended to assess long-term performance and the overall service life of the liner.

  15. Evaluation of Mycology Laboratory Proficiency Testing

    OpenAIRE

    Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max

    1999-01-01

    Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient te...

  16. SDU6 Interior Liner Testing & Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Skidmore, T. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-10-14

    Two liner materials (Marseal® M-3500 and REMA Chemoline® 4CN) proposed for use as a liner inside the Saltstone Disposal Unit 6 (SDU6) were subjected to specific ASTM tests (tensile and lap-shear) after immersion in 50% and 100% simulant solutions for 1000 hours at the Savannah River Ecology Laboratory. Both liner materials exhibited good resistance to the simulant chemistry, at least based on the tests performed and the test duration/conditions imposed. In lap-shear tests, both materials failed in the base material rather than peeling apart, confirming good adhesion. The REMA 4CN bromobutyl elastomer showed superior bonding characteristics and absence of warping or delamination at the conditions tested. The Marseal M-3500 material (PVC/EVA blend with polyester reinforcement) exhibited deformation and debonding in some locations. The cause of the deformation and delamination observed in the Marseal M-3500 material is not fully known, but possibly attributed to thermomechanical stress at immersion temperatures, and the thermoplastic nature of the material. The immersion temperature (68 °C) is slightly greater than the maximum use temperature limit quoted for the Marseal M- 3500 liner (65 °C), though the basis for the service limit is unknown. The testing performed was limited in scope and only for these two liner materials. These tests were primarily performed to screen for severe incompatibility or short-term degradation in Saltstone bleedwater simulants at bounding solution temperatures. Additional testing is recommended to assess long-term performance and the overall service life of the liner.

  17. Field tests of acoustic telemetry for a portable coastal observatory

    Science.gov (United States)

    Martini, M.; Butman, B.; Ware, J.; Frye, D.

    2006-01-01

    Long-term field tests of a low-cost acoustic telemetry system were carried out at two sites in Massachusetts Bay. At each site, an acoustic Doppler current profiler mounted on a bottom tripod was fitted with an acoustic modem to transmit data to a surface buoy; electronics mounted on the buoy relayed these data to shore via radio modem. The mooring at one site (24 m water depth) was custom-designed for the telemetry application, with a custom designed small buoy, a flexible electro-mechanical buoy to mooring joint using a molded chain connection to the buoy, quick-release electro-mechanical couplings, and dual hydrophones suspended 7 m above the bottom. The surface buoy at the second site (33 m water depth) was a U.S. Coast Guard (USCG) channel buoy fitted with telemetry electronics and clamps to hold the hydrophones. The telemetry was tested in several configurations for a period of about four years. The custom-designed buoy and mooring provided nearly error-free data transmission through the acoustic link under a variety of oceanographic conditions for 261 days at the 24 m site. The electro mechanical joint, cables and couplings required minimal servicing and were very reliable, lasting 862 days deployed before needing repairs. The acoustic communication results from the USCG buoy were poor, apparently due to the hard cobble bottom, noise from the all-steel buoy, and failure of the hydrophone assembly. Access to the USCG buoy at sea required ideal weather. ??2006 IEEE.

  18. Visual field measurement with motion sensitivity screening test

    African Journals Online (AJOL)

    has been shown that early ocular lesions which manifest as visual field defects or ... easy-to-understand computer perimetry that could be useful in monitoring visual field changes in onchocer- .... education with the equivalent of ordinary level.

  19. Automated Critical Peak Pricing Field Tests: Program Descriptionand Results

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Xu, Peng

    2006-04-06

    California utilities have been exploring the use of critical peak prices (CPP) to help reduce needle peaks in customer end-use loads. CPP is a form of price-responsive demand response (DR). Recent experience has shown that customers have limited knowledge of how to operate their facilities in order to reduce their electricity costs under CPP (Quantum 2004). While the lack of knowledge about how to develop and implement DR control strategies is a barrier to participation in DR programs like CPP, another barrier is the lack of automation of DR systems. During 2003 and 2004, the PIER Demand Response Research Center (DRRC) conducted a series of tests of fully automated electric demand response (Auto-DR) at 18 facilities. Overall, the average of the site-specific average coincident demand reductions was 8% from a variety of building types and facilities. Many electricity customers have suggested that automation will help them institutionalize their electric demand savings and improve their overall response and DR repeatability. This report focuses on and discusses the specific results of the Automated Critical Peak Pricing (Auto-CPP, a specific type of Auto-DR) tests that took place during 2005, which build on the automated demand response (Auto-DR) research conducted through PIER and the DRRC in 2003 and 2004. The long-term goal of this project is to understand the technical opportunities of automating demand response and to remove technical and market impediments to large-scale implementation of automated demand response (Auto-DR) in buildings and industry. A second goal of this research is to understand and identify best practices for DR strategies and opportunities. The specific objectives of the Automated Critical Peak Pricing test were as follows: (1) Demonstrate how an automated notification system for critical peak pricing can be used in large commercial facilities for demand response (DR). (2) Evaluate effectiveness of such a system. (3) Determine how customers

  20. Evaluation practices in the field of Food and Nutrition

    Directory of Open Access Journals (Sweden)

    Max Felipe Vianna GASPARINI

    Full Text Available ABSTRACT The objective of this study was to characterize and analyze the different existing methods for the evaluation of food and nutrition programs and services in Brazil, through a systematic review of the literature focused on complete articles published in national indexed journals. We searched the PubMed, MedLine and LILACS databases using the following search terms and Boolean operators: “evaluation and program”; “project”; “intervention”; “servisse”; “actions and nutrition”; “nutritional”. The research was restricted to articles written in Portuguese, English and Spanish and published between 2001 and 2015. Twenty-two studies were selected and the analysis indicates; most were carried out through quantitative approaches and external evaluations based on epidemiological theory; participatory evaluation strategies are still uncommon; Impact assessments and implementation were predominant; there is little diversity in terms of references to the theoretical framework in the field of evaluation of health care programs in the planning and execution of the evaluation processes analyzed. The results of this study indicate the need for a more comprehensive evaluation considering the complexity of the interventions evaluated using the theoretical-methodological apparatus available in the literature to understand the importance of the different perspectives of the agents involved in the evaluation processes.

  1. Uncertainty Evaluation of Residential Central Air-conditioning Test System

    Science.gov (United States)

    Li, Haoxue

    2018-04-01

    According to national standards, property tests of air-conditioning are required. However, test results could be influenced by the precision of apparatus or measure errors. Therefore, uncertainty evaluation of property tests should be conducted. In this paper, the uncertainties are calculated on the property tests of Xinfei13.6 kW residential central air-conditioning. The evaluation result shows that the property tests are credible.

  2. Geomechanical Considerations for the Deep Borehole Field Test

    Science.gov (United States)

    Park, B. Y.

    2015-12-01

    Deep borehole disposal of high-level radioactive waste is under consideration as a potential alternative to shallower mined repositories. The disposal concept consists of drilling a borehole into crystalline basement rocks to a depth of 5 km, emplacement of canisters containing solid waste in the lower 2 km, and plugging and sealing the upper 3 km of the borehole. Crystalline rocks such as granites are particularly attractive for borehole emplacement because of their low permeability and porosity at depth, and high mechanical strength to resist borehole deformation. In addition, high overburden pressures contribute to sealing of some of the fractures that provide transport pathways. We present geomechanical considerations during construction (e.g., borehole breakouts, disturbed rock zone development, and creep closure), relevant to both the smaller-diameter characterization borehole (8.5") and the larger-diameter field test borehole (17"). Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  3. The Savannah River Technology Center environmental monitoring field test platform

    International Nuclear Information System (INIS)

    Rossabi, J.

    1993-01-01

    Nearly all industrial facilities have been responsible for introducing synthetic chemicals into the environment. The Savannah River Site is no exception. Several areas at the site have been contaminated by chlorinated volatile organic chemicals. Because of the persistence and refractory nature of these contaminants, a complete clean up of the site will take many years. A major focus of the mission of the Environmental Sciences Section of the Savannah River Technology Center is to develop better, faster, and less expensive methods for characterizing, monitoring, and remediating the subsurface. These new methods can then be applied directly at the Savannah River Site and at other contaminated areas in the United States and throughout the world. The Environmental Sciences Section has hosted field testing of many different monitoring technologies over the past two years primarily as a result of the Integrated Demonstration Program sponsored by the Department of Energy's Office of Technology Development. This paper provides an overview of some of the technologies that have been demonstrated at the site and briefly discusses the applicability of these techniques

  4. A test on reactive force fields for the study of silica dimerization reactions

    Energy Technology Data Exchange (ETDEWEB)

    Moqadam, Mahmoud; Riccardi, Enrico; Trinh, Thuat T.; Åstrand, Per-Olof; Erp, Titus S. van, E-mail: titus.van.erp@ntnu.no [Department of Chemistry, Norwegian University of Science and Technology (NTNU), Høgskoleringen 5, Realfagbygget D3-117, 7491 Trondheim (Norway)

    2015-11-14

    We studied silica dimerization reactions in the gas and aqueous phase by density functional theory (DFT) and reactive force fields based on two parameterizations of ReaxFF. For each method (both ReaxFF force fields and DFT), we performed constrained geometry optimizations, which were subsequently evaluated in single point energy calculations using the other two methods. Standard fitting procedures typically compare the force field energies and geometries with those from quantum mechanical data after a geometry optimization. The initial configurations for the force field optimization are usually the minimum energy structures of the ab initio database. Hence, the ab initio method dictates which structures are being examined and force field parameters are being adjusted in order to minimize the differences with the ab initio data. As a result, this approach will not exclude the possibility that the force field predicts stable geometries or low transition states which are realistically very high in energy and, therefore, never considered by the ab initio method. Our analysis reveals the existence of such unphysical geometries even at unreactive conditions where the distance between the reactants is large. To test the effect of these discrepancies, we launched molecular dynamics simulations using DFT and ReaxFF and observed spurious reactions for both ReaxFF force fields. Our results suggest that the standard procedures for parameter fitting need to be improved by a mutual comparative method.

  5. The inverse problem to the evaluation of magnetic fields

    Science.gov (United States)

    Caspi, S.; Helm, M.; Laslett, L. J.; Brady, V.

    1992-12-01

    In the design of superconducting magnet elements, such as may be required to guide and focus ions in a particle accelerator, one frequently premises some particular current distribution and then proceeds to compute the consequent magnetic field through use of the laws of Biot and Savart or of Ampere. When working in this manner one of course may need to revise frequently the postulated current distribution before arriving at a resulting magnetic field of acceptable field quality. It therefore is of interest to consider an alternative ('inverse') procedure in which one specifies a desired character for the field required in the region interior to the winding and undertakes them to evaluate the current distribution on the specified winding surface that would provide this desired field. We may note that in undertaking such an inverse procedure we would wish, on practical grounds, to avoid the use of any 'double-layer' distributions of current on the winding surface or interface but would not demand that no fields be generated in the exterior region, so that in this respect the goal would differ in detail from that discussed by other authors, in analogy to the distribution sought in electrostatics by the so-caged Green's equivalent stratum.

  6. Field tests on partial embedment effects (embedment effect tests on soil-structure interaction)

    International Nuclear Information System (INIS)

    Kurimoto, O.; Tsunoda, T.; Inoue, T.; Izumi, M.; Kusakabe, K.; Akino, K.

    1993-01-01

    A series of Model Tests of Embedment Effect on Reactor Buildings has been carried out by the Nuclear Power Engineering Corporation (NUPEC), under the sponsorship of the Ministry of International Trade and lndustry (MITI) of Japan. The nuclear reactor buildings are partially embedded due to conditions for the construction or building arrangement in Japan. It is necessary to verify the partial embedment effects by experiments and analytical studies in order to incorporate the effects in the seismic design. Forced vibration tests, therefore, were performed using a model with several types of embedment. Correlated simulation analyses were also performed and the characteristics of partial embedment effects on soil-structure interaction were evaluated. (author)

  7. Testing and evaluation of eight decontamination chemicals

    International Nuclear Information System (INIS)

    Demmer, R.

    1994-09-01

    This report covers experimental work comparing eight different decontamination chemicals. Seven of these chemicals have some novelty, or are not currently in use at the ICPP. The eighth is a common ICPP decontamination reagent used as a baseline for effective comparison. Decontamination factors, waste generation values, and corrosion rates are tabulated for these chemicals. Recommendations are given for effective methods of non-sodium or low-sodium decontamination chemicals. The two most effective chemical for decontamination found in these test were a dilute hydrofluoric and nitric acid (HF/HNO 3 ) mixture and a fluoroboric acid solution. The fluoroboric acid solution (1 molar) was by far the most effective decontamination reagent, but suffered the problem of generating significant final calcine volume. The HF/HNO 3 solution performed a very good decontamination of the SIMCON coupons while generating only small amounts of calcine volume. Concentration variables were also tested, and optimized for these two solutions. Several oxidation/reduction decon chemical systems were also tested. These systems were similar to the TURCO 4502 and TURCO 4521 solutions used for general decontamination at the ICPP. A low sodium alternative, nitric acid/potassium permanganate, to the ''high sodium'' TURCO 4502 was tested extensively, optimized and recommended for general ICPP use. A reductive chemical solution, oxalic acid/nitric acid was also shown to have significant advantages

  8. OCOD-CTTP Test Evaluation Report.

    Science.gov (United States)

    Shorey, Leonard

    Tests in social studies and integrated science given in Saint Vincent, Saint Lucia, Grenada, and Dominica were analyzed by the Organization for Co-operation in Overseas Development (OCOD) Comprehensive Teacher Training Program (CTTP) for discrimination, difficulty, and reliability, as well as other characteristics. There were 767 examinees for the…

  9. [Evaluation of pendulum testing of spasticity].

    Science.gov (United States)

    Le Cavorzin, P; Hernot, X; Bartier, O; Carrault, G; Chagneau, F; Gallien, P; Allain, H; Rochcongar, P

    2002-11-01

    To identify valid measurements of spasticity derived from the pendulum test of the leg in a representative population of spastic patients. Pendulum testing was performed in 15 spastic and 10 matched healthy subjects. The reflex-mediated torque evoked in quadriceps femoris, as well as muscle mechanical parameters (viscosity and elasticity), were calculated using mathematical modelling. Correlation with the two main measures derived from the pendulum test reported in the literature (the Relaxation Index and the area under the curve) was calculated in order to select the most valid. Among mechanical parameters, only viscosity was found to be significantly higher in the spastic group. As expected, the computed integral of the reflex-mediated torque was found to be larger in spastics than in healthy subjects. A significant non-linear (logarithmic) correlation was found between the clinically-assessed muscle spasticity (Ashworth grading) and the computed reflex-mediated torque, emphasising the non-linear behaviour of this scale. Among measurements derived from the pendulum test which are proposed in the literature for routine estimation of spasticity, the Relaxation Index exhibited an unsuitable U-shaped pattern of variation with increasing reflex-mediated torque. On the opposite, the area under the curve revealed a linear regression, which is more convenient for routine estimation of spasticity. The pendulum test of the leg is a simple technique for the assessment of spastic hypertonia. However, the measurement generally used in the literature (the Relaxation Index) exhibits serious limitations, and would benefit to be replaced by more valid measures, such as the area under the goniometric curve, especially for the assessment of therapeutics.

  10. Retraction: Evaluation of Carcinogenic Effects of Electromagnetic Fields (Emf

    Directory of Open Access Journals (Sweden)

    Bakir Mehic

    2010-08-01

    Full Text Available This retracts the article "EVALUATION OF CARCINOGENIC EFFECTS OF ELECTROMAGNETIC FIELDS (EMF" on page 245. The Editor-in-chief of the Bosnian Journal ofBasic Medical Sciences has decided to retract the article from Bayazit V et al. [1] entitled as: “Evaluation of carcinogenic effects of electromagnetic fields (EMF” published in Bosn J Basic Med Sci. 2010 Aug;10(3:245-50.After the editorial office was alerted of possible plagiarism in the article, it conducted thorough investigation and concluded that the article apparently represents plagiarized material from two World Health Organization reports, one European Commission report and other sources. Since this is considered scientific plagiarism and scientific misconduct, Editor-in-chief has decided to withdraw the article. The authors have agreed with the editorial office decision.

  11. Comparison Between 30-15 Intermittent Fitness Test and Multistage Field Test on Physiological Responses in Wheelchair Basketball Players

    OpenAIRE

    Weissland, Thierry; Faupin, Arnaud; Borel, Benoit; Leprêtre, Pierre-Marie

    2015-01-01

    The intermittent nature of wheelchair court sports suggests using a similar protocol to assess repeated shuttles and recovery abilities. This study aimed to compare performances, physiological responses and perceived rating exertion obtained from the continuous multistage field test (MFT) and the 30-15 intermittent field test (30-15IFT). Eighteen trained wheelchair basketball players (WBP) (WBP: 32.0 ? 5.7 y, IWBF classification: 2.9 ? 1.1 points) performed both incremental field tests in ran...

  12. MicroCHP: Overview of selected technologies, products and field test results

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Vollrad [Berliner Energieagentur GmbH, Franzoesische Strasse 23, 10117 Berlin (Germany); Klemes, Jiri; Bulatov, Igor [Centre for Process Integration, CEAS, The University of Manchester, P.O. Box 88, M60 1QD Manchester (United Kingdom)

    2008-11-15

    This paper gives an overview on selected microCHP technologies and products with the focus on Stirling and steam machines. Field tests in Germany, the UK and some other EC countries are presented, assessed and evaluated. Test results show the overall positive performance with differences in sectors (domestic vs. small business). Some negative experiences have been received, especially from tests with the Stirling engines and the free-piston steam machine. There are still obstacles for market implementation. Further projects and tests of microCHP are starting in various countries. When positive results will prevail and deficiencies are eliminated, a way to large-scale production and market implementation could be opened. (author)

  13. Field test of radioactive high efficiency filter and filter exchange techniques of fuel cycle examination facility

    International Nuclear Information System (INIS)

    Hwang, Yong Hwa; Lee, Hyung Kwon; Chun, Young Bum; Park, Dae Gyu; Ahn, Sang Bok; Chu, Yong Sun; Kim, Eun Ka.

    1997-12-01

    The development of high efficiency filter was started to protect human beings from the contamination of radioactive particles, toxic gases and bacillus, and its gradual performance increment led to the fabrication of Ultra Low Penetration Air Filter (ULPA) today. The application field of ULPA has been spread not only to the air conditioning of nuclear power facilities, semiconductor industries, life science, optics, medical care and general facilities but also to the core of ultra-precision facilities. Periodic performance test on the filters is essential to extend its life-time through effective maintenance. Especially, the bank test on HEPA filter of nuclear facilities handling radioactive materials is required for environmental safety. Nowadays, the bank test technology has been reached to the utilization of a minimized portable detecting instruments and the evaluation techniques can provide high confidence in the area of particle distribution and leakage test efficiency. (author). 16 refs., 13 tabs., 14 figs

  14. Large-scale field testing on flexible shallow landslide barriers

    Science.gov (United States)

    Bugnion, Louis; Volkwein, Axel; Wendeler, Corinna; Roth, Andrea

    2010-05-01

    Open shallow landslides occur regularly in a wide range of natural terrains. Generally, they are difficult to predict and result in damages to properties and disruption of transportation systems. In order to improve the knowledge about the physical process itself and to develop new protection measures, large-scale field experiments were conducted in Veltheim, Switzerland. Material was released down a 30° inclined test slope into a flexible barrier. The flow as well as the impact into the barrier was monitored using various measurement techniques. Laser devices recording flow heights, a special force plate measuring normal and shear basal forces as well as load cells for impact pressures were installed along the test slope. In addition, load cells were built in the support and retaining cables of the barrier to provide data for detailed back-calculation of load distribution during impact. For the last test series an additional guiding wall in flow direction on both sides of the barrier was installed to achieve higher impact pressures in the middle of the barrier. With these guiding walls the flow is not able to spread out before hitting the barrier. A special constructed release mechanism simulating the sudden failure of the slope was designed such that about 50 m3 of mixed earth and gravel saturated with water can be released in an instant. Analysis of cable forces combined with impact pressures and velocity measurements during a test series allow us now to develop a load model for the barrier design. First numerical simulations with the software tool FARO, originally developed for rockfall barriers and afterwards calibrated for debris flow impacts, lead already to structural improvements on barrier design. Decisive for the barrier design is the first dynamic impact pressure depending on the flow velocity and afterwards the hydrostatic pressure of the complete retained material behind the barrier. Therefore volume estimation of open shallow landslides by assessing

  15. 40 CFR 63.2354 - What performance tests, design evaluations, and performance evaluations must I conduct?

    Science.gov (United States)

    2010-07-01

    ... evaluations, and performance evaluations must I conduct? 63.2354 Section 63.2354 Protection of Environment... tests, design evaluations, and performance evaluations must I conduct? (a)(1) For each performance test... procedures specified in subpart SS of this part. (3) For each performance evaluation of a continuous emission...

  16. The evaluation and impact of diagnostic tests

    International Nuclear Information System (INIS)

    Royal, H.D.; McNeil, B.J.

    1989-01-01

    The authors describe the usefulness of the techniques that are applied to study the role of tests and point out their limitations. In many instances, complex tasks must be oversimplified in order to use currently available analytic tools. Certain tools, such as decision analysis, are useful not only because they can provide insight regarding the most favorable diagnostic/therapeutic strategies but also because they can identify areas where present knowledge is inadequate and thereby help put priorities on areas of research

  17. Comprehensive evaluation of attitude and orbit estimation using real earth magnetic field data

    Science.gov (United States)

    Deutschmann, Julie; Bar-Itzhack, Itzhack

    1997-01-01

    A single, augmented extended Kalman filter (EKF) which simultaneously and autonomously estimates spacecraft attitude and orbit was developed and tested with simulated and real magnetometer and rate data. Since the earth's magnetic field is a function of time and position, and since time is accurately known, the differences between the computed and measured magnetic field components, as measured by the magnetometers throughout the entire spacecraft's orbit, are a function of orbit and attitude errors. These differences can be used to estimate the orbit and attitude. The test results of the EKF with magnetometer and gyro data from three NASA satellites are presented and evaluated.

  18. On multiplying methods in the field of research evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Derrick, G.; Molas-Gallart, J.; De Rijcke, S.; Meijer, I.; Van der Weijden, I.; Wouters, P.

    2016-07-01

    This special session forms part of a larger program aimed at the multiplication and integration of methodological approaches in the research evaluation and innovation policy field. The session builds on previous initiatives by Gemma Derrick and colleagues at CWTS, INGENIO, the Rathenau Instituut and SPRU, exploring the advantages of qualitative methodological tools at the STI/ENID conference in Lugano, and an international workshop in London in October 2015. The program is highly topical: the research evaluation field is currently reconsidering its methodological foundations in light of new research questions arising from policy initiatives regarding a) the move toward open science; b) a reconceptualization of research excellence to include societal relevance; c) diversification of academic careers, and d) the search for indicators showcasing responsible research behavior and innovation. This new special session at STI2016 will advance and broaden the scope of previous initiatives by building bridges between cutting edge research involving quantitative, qualitative, and mixed methodological research designs. Bringing together leading experts and promising researchers with distinctive methodological skill-sets, the session will demonstrate the advantages of cross-fertilization between ‘core’ and ‘peripheral’ methodological approaches for the research evaluation and science indicators field. (Author)

  19. Heart Rate Measures of Flight Test and Evaluation

    National Research Council Canada - National Science Library

    Bonner, Malcolm A; Wilson, Glenn F

    2001-01-01

    .... Because flying is a complex task, several measures are required to derive the best evaluation. This article describes the use of heart rate to augment the typical performance and subjective measures used in test and evaluation...

  20. Table 1. Summary of Field Testing and Measurement Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Key performance parameters measured during the field demonstration such as lining thickness, compressive strength, Flexural Strength, Modulus of Elasticity, bond...

  1. ASTM test methods for composite characterization and evaluation

    Science.gov (United States)

    Masters, John E.

    1994-01-01

    A discussion of the American Society for Testing and Materials is given. Under the topic of composite materials characterization and evaluation, general industry practice and test methods for textile composites are presented.

  2. Experiments and Modeling to Support Field Test Design

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Peter Jacob [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bourret, Suzanne Michelle [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Zyvoloski, George Anthony [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Boukhalfa, Hakim [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stauffer, Philip H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Weaver, Douglas James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-25

    Disposition of heat-generating nuclear waste (HGNW) remains a continuing technical and sociopolitical challenge. We define HGNW as the combination of both heat generating defense high level waste (DHLW) and civilian spent nuclear fuel (SNF). Numerous concepts for HGNW management have been proposed and examined internationally, including an extensive focus on geologic disposal (c.f. Brunnengräber et al., 2013). One type of proposed geologic material is salt, so chosen because of its viscoplastic deformation that causes self-repair of damage or deformation induced in the salt by waste emplacement activities (Hansen and Leigh, 2011). Salt as a repository material has been tested at several sites around the world, notably the Morsleben facility in Germany (c.f. Fahland and Heusermann, 2013; Wollrath et al., 2014; Fahland et al., 2015) and at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, NM. Evaluating the technical feasibility of a HGNW repository in salt is an ongoing process involving experiments and numerical modeling of many processes at many facilities.

  3. Evaluation of the field size in dental diagnostic radiology system

    International Nuclear Information System (INIS)

    Andrade, P.S.; Potiens, M.P.A.

    2006-01-01

    In this work the field size of a dental X rays machine was evaluated considering the recommendation of the Brazilian Health Ministry Regulation 453 which established basic lines of radiological protection in medical and dental diagnostic radiology. The diameter of the field should not be superior to 6 cm in the localized end point, limiting the radiated area and protecting the head-neck region. The measurements were carried out in a dental X rays machine, Dabi Atlante, model Spectro 70X Seletronic. For the field size or useful beam determination, the intra-oral films were positioned on a plain surface to be exposed in four stages and two focus-film distances (FFD), 20 cm and 27.5 cm: 1) with spacer cone; 2) without spacer cone; 3) with spacer cone and film-holding device; 4) without spacer cone and film-holding device. The results show that the diameter of the field size is satisfactory only for FFD = 20 cm. When the film-holding device is used, which is recommended by the Regulation 453, item 5.8 d(ii), the diameter of the field size exceeds the maximum recommended value of 6 cm. (authors)

  4. Economic evaluation of soil fertility management in groundnut fields ...

    African Journals Online (AJOL)

    This paper provides the economic evaluation of soil fertility replenishing technologies (use of inorganic fertilizers, organic manure, and rhizobium inoculant) that were tested and recommended. Data on groundnut technologies used, yields, resource availability and use, and farmers' characteristics were collected through ...

  5. Management and Use of Director, Operational Test and Evaluation Funds

    National Research Council Canada - National Science Library

    2000-01-01

    .... The reorganization disestablished the functions of the Director, Test, Systems Engineering, and Evaluation, within the Office of Under Secretary of Defense for Acquisition, Technology, and Logistics...

  6. Laboratory and field tests of the Sutron RLR-0003-1 water level sensor

    Science.gov (United States)

    Fulford, Janice M.; Bryars, R. Scott

    2015-01-01

    Three Sutron RLR-0003-1 water level sensors were tested in laboratory conditions to evaluate the accuracy of the sensor over the manufacturer’s specified operating temperature and distance-to-water ranges. The sensor was also tested for compliance to SDI-12 communication protocol and in field conditions at a U.S. Geological Survey (USGS) streamgaging site. Laboratory results were compared to the manufacturer’s accuracy specification for water level and to the USGS Office of Surface Water (OSW) policy requirement that water level sensors have a measurement uncertainty of no more than 0.01 foot or 0.20 percent of the indicated reading. Except for one sensor, the differences for the temperature testing were within 0.05 foot and the average measurements for the sensors were within the manufacturer’s accuracy specification. Two of the three sensors were within the manufacturer’s specified accuracy and met the USGS accuracy requirements for the laboratory distance to water testing. Three units passed a basic SDI-12 communication compliance test. Water level measurements made by the Sutron RLR-0003-1 during field testing agreed well with those made by the bubbler system and a Design Analysis Associates (DAA) H3613 radar, and they met the USGS accuracy requirements when compared to the wire-weight gage readings.

  7. Reasearch and Evaluation of Electromagnetic Fields of Refrigerators

    Directory of Open Access Journals (Sweden)

    Pranas Baltrėnas

    2013-12-01

    Full Text Available The use of refrigerators causes the occurence of electromagnetic fields that are invisible and intangible, which therefore makes difficulties in protecting ourselves from them. A refrigerator is an irreplaceable item in domestic household and thus can be hardly ignored by a modern way of human life. In order to preserve the characteristics of products, the refrigerator must operate continuously (24 hrs a day, regardless of the time of the year. This results in a huge increase in electricity consumption, which leads to energy consumption related pollution of the environment emitting CO2 gas. On these grounds, it is necessary to assess electromagnetic fields created by the refrigerator. Studies on electromagnetic fields produced by refrigerators were conducted in domestic premises where people spent a significant part of the day. For comparison purposes, five different power refrigerators were chosen (1 – 0.20 kW; 2 – 0.25 kW; 3 – 0.30 kW; 4 – 0.35 kW; 5 – 0.40 kW. The obtained results, according to the parameters of their electromagnetic fields, were presented in graphs and charts and showed that the values of electric and magnetic intensity of refrigerators depended on the distance and the power of the refrigerator. The conducted research also disclosed that none of tested refrigerators exceeded the permissible limits of electromagnetic fields.Article in Lithuanian

  8. Materials for the field test - students' attitudes to nuclear power stations

    International Nuclear Information System (INIS)

    Hoffmann, L.; Kattmann, U.; Lucht, H.; Spada, H.

    1975-01-01

    This working paper contains all the materials developed for and used in the field test of 'Student Attitudes toward Atomic Power Stations'. This research is a component of a larger project called 'Attitudes and Attitudes Change with Regard to Problems of Energy Supply and their Consequences for our Environment'. A central aim of this project is the development of instrumental strategies enabling the student to build up in this field a critically reflective and active behavior and attitudes based on sound problem consciousness. These instrumental strategies are derived from theories of social, learning and environmental psychology. A concrete result of these efforts are the materials of the field test mentioned above. They include: a) The draft of an instructional unit 'Atomic Power Stations - Prosperity or Disaster' with - a booklet on the subject matter for students and teachers - a paper on the contents of the instructional unit and their sequence - information for the students concerning the aims of the investigation - working materials for the students - reading materials for the teachers informing them about the proposed instructional strategies based on the psychological theories: (1) model-learning and the structuring of knowledge, (2) how to activate and motivate students, (3) the stabilization of attitudes and (4) small group work. b) Instruments for testing and observation. These instruments were used within a criterion-oriented evaluation and for a test of the effects of the different proposed items used in the instruction. (orig./HP) [de

  9. Evaluation of screening tests for colorectal cancer.

    Science.gov (United States)

    Bolt, R J

    1980-12-01

    The following guidelines are proposed for the asymptomatic patient representing for routine examination. Instruct the patient to eat All Bran cereal or a similar product for breakfast for three consecutive days prior to the day of appointment. At the time of appointment the stool obtained from rectal examination or from a spontaneous bowel movement is checked for occult blood using the guaiac method. If the findings are negative, no further tests are recommended. If positive, the patient is given complete dietary instructions in a non-meat, high-residue diet with avoidance of beets, horseradish, vitamins, or aspirin-containing compounds. The patient is then given six Hemoccult or Quikcult slides and is instructed to prepare two fecal slides from each stool specimen daily for three days. If these are all negative when tested, no further studies are necessary. If one or more are positive, however, sigmoidoscopic examination and colon and upper gastrointestinal radiography should be carried out in that order. Evidence that early lesions (Duke A or B) are detected and the cure rate improved with this procedure is quite convincing.

  10. Evaluation of ring tensile test results

    International Nuclear Information System (INIS)

    Chatterjee, S.; Anantharaman, S.; Balakrishnan, K.S.; Sivaramakrish, K.S.

    1990-01-01

    Ring specimens of 5-mm width cut from Zircaloy-2 cladding of reactor operated fuel elements that had experienced 5000 to 15,000 MWD/T of fuel burnup were subjected to ring tensile testing. The true stress-true strain data points up to the onset of necking from the individual load-elongation curves of these specimens were used as input data in Voce's equation. The results reveal that the uniform elongation (UE) values generated using Voce's equation were within (UE-2)% of the experimental percent uniform elongation (UE%). The corresponding ultimate tensile strength values were within ±1%. The uncertainty inherently associated in the determination of gauge length introduces extraneous deformation in the rings tested. Previous results had shown that a 14% increase in cladding diameter caused the gauge length to increase by 40%. To simulate the contribution of extraneous deformation due to an increase in cladding diameter, an analysis of the variation of the tensile parameters (uniform elongation and ultimate tensile strength) due to increase in the gauge length in the range of 10 to 40% was carried out. The results are discussed

  11. The sit up test to exhaustion as a test for muscular endurance evaluation.

    Science.gov (United States)

    Bianco, Antonino; Lupo, Corrado; Alesi, Marianna; Spina, Serena; Raccuglia, Margherita; Thomas, Ewan; Paoli, Antonio; Palma, Antonio

    2015-01-01

    The aim of this study was to examine the sit up test to exhaustion as a field test for muscular endurance evaluation in a sample of sedentary people of both sexes. A cross-sectional study was performed. Three-hundred-eighty-one participants volunteered for the study (28.5 ± 10.0 years; 168.2 ± 8.9 cm; 65.1 ± 11.1 kg), of which 194 males (27.5 ± 10.2 years; 173.6 ± 7.0 cm; 71.2 ± 5.2 kg) and 187 females (29.6 ± 10.1 years; 162.6 ± 7.1 cm; 58.7 ± 8.9 kg). Each subject voluntarily and randomly performed: a sit up test (SUT), a push up test (PUT), and a free weight squat test (ST), all till exhaustion. A multiple regression analysis was adopted for data analysis. Subsequently a percentile model for muscle endurance was developed. The 25th, 50th, and 75th percentile were identified as upper limit for low muscular endurance, average muscular endurance, and lower limit for high muscular endurance, respectively. Considering the sit up test as the dependent variable, the coefficients (R(2) = 0.23; r = 0.49; p squat test, respectively. Gender stratification showed regression coefficients of (R(2) = 0.19; r = 0.44; p < 0.001) for SUT vs. PUT, and (R(2) = 0.30; r = 0.56; p < 0.001) for SUT vs. ST in male; and (R(2) = 0.23; r = 0.49; p < 0.001) for SUT vs. PUT, and (R(2) = 0.34; r = 0.59; p < 0.001) for SUT vs. ST in female. The SUT showed low inter-relation with the other proposed tests indicating that the adoption of a single test for the global evaluation of muscle endurance is not the optimal approach. Moreover, the SUT was found to be inexpensive, safe, and appropriate for core muscle endurance measurement for both male and female.

  12. Measurement of physical performance by field tests in programs of cardiac rehabilitation: a systematic review and meta-analysis.

    Science.gov (United States)

    Travensolo, Cristiane; Goessler, Karla; Poton, Roberto; Pinto, Roberta Ramos; Polito, Marcos Doederlein

    2018-04-13

    The literature concerning the effects of cardiac rehabilitation (CR) on field tests results is inconsistent. To perform a systematic review with meta-analysis on field tests results after programs of CR. Studies published in PubMed and Web of Science databases until May 2016 were analyzed. The standard difference in means correct by bias (Hedges' g) was used as effect size (g) to measure que amount of modifications in performance of field tests after CR period. Potential differences between subgroups were analyzed by Q-test based on ANOVA. Fifteen studies published between 1996 e 2016 were included in the review, 932 patients and age ranged 54,4 - 75,3 years old. Fourteen studies used the six-minutes walking test to evaluate the exercise capacity and one study used the Shuttle Walk Test. The random Hedges's g was 0.617 (P<0.001), representing a drop of 20% in the performance of field test after CR. The meta-regression showed significantly association (P=0.01) to aerobic exercise duration, i.e., for each 1-min increase in aerobic exercise duration, there is a 0.02 increase in effect size for performance in the field test. Field tests can detect physical modification after CR, and the large duration of aerobic exercise during CR was associated with a better result. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Orthodontic brackets in high field MR imaging: experimental evaluation of magnetic field interactions at 3.0 tesla

    International Nuclear Information System (INIS)

    Kemper, J.; Adam, G.; Klocke, A.; Kahl-Nieke, B.

    2005-01-01

    Purpose: To evaluate static magnetic field interactions for 32 commonly used orthodontic brackets in a 3.0 T magnetic resonance imaging (MRI) system. Materials and methods: 32 orthodontic brackets consisting of a steel alloy (n=27), a cobalt-chromium alloy (n=2), ceramic (n=1), ceramic with a steel slot (n=1), and titanium (n=1) from 13 different manufacturers were tested for magnetic field interactions in a static magnetic field at 3.0 T (Gyroscan Intera 3.0 T, Philips Medical Systems, Best, Netherlands). The magnetic deflection force F Z [mN] was evaluated by determining the deflection angle β[ ] using the established deflection angle test according to the ASTM guidelines. The magnetic-field-induced rotational force F rot or torque was qualitatively determined using a 5-point grading scale (0: no torque; +4: very strong torque). Results: In 18 of the 32 brackets, the deflection angle β was found to be > 45 and the translational force exceeded the gravitational force F G on the particular bracket (F Z : 1.2-45.7 mN). The translational force F Z was found to be up to 68.5 times greater than the gravitational force F G (F Z /F G : 1.4-68.5). The rotational force F rot was correspondingly high (+3/+4) for those brackets. For the remaining 14 objects, the deflection angles were < 45 and the torque measurements ranged from 0 to +2. The static magnetic field did not affect the titanium bracket and the ceramic bracket. No measurable translational and rotational forces were found. (orig.)

  14. Evaluation of hydrogen sulphide test for detection of fecal coliform ...

    African Journals Online (AJOL)

    GREGO

    2007-03-19

    Mar 19, 2007 ... on production of hydrogen sulphide by bacteria that are associated with fecal contamination. This rapid fields test needs no technical staff and the cost is lower than ..... Sources and Potable Water Supplies in Peru.

  15. Verification, validation, and field testing the USEPA National Stormwater Calculator

    Data.gov (United States)

    U.S. Environmental Protection Agency — We used this dataset to verify and validate functions in the USEPA National Stormwater Calculator, and then applied field data and commonly-available datasets to...

  16. Evaluation of Depth of Field for depth perception in DVR

    KAUST Repository

    Grosset, A.V.Pascal; Schott, Mathias; Bonneau, Georges-Pierre; Hansen, Charles D.

    2013-01-01

    In this paper we present a user study on the use of Depth of Field for depth perception in Direct Volume Rendering. Direct Volume Rendering with Phong shading and perspective projection is used as the baseline. Depth of Field is then added to see its impact on the correct perception of ordinal depth. Accuracy and response time are used as the metrics to evaluate the usefulness of Depth of Field. The onsite user study has two parts: static and dynamic. Eye tracking is used to monitor the gaze of the subjects. From our results we see that though Depth of Field does not act as a proper depth cue in all conditions, it can be used to reinforce the perception of which feature is in front of the other. The best results (high accuracy & fast response time) for correct perception of ordinal depth occurs when the front feature (out of the two features users were to choose from) is in focus and perspective projection is used. © 2013 IEEE.

  17. Evaluation of Depth of Field for depth perception in DVR

    KAUST Repository

    Grosset, A.V.Pascal

    2013-02-01

    In this paper we present a user study on the use of Depth of Field for depth perception in Direct Volume Rendering. Direct Volume Rendering with Phong shading and perspective projection is used as the baseline. Depth of Field is then added to see its impact on the correct perception of ordinal depth. Accuracy and response time are used as the metrics to evaluate the usefulness of Depth of Field. The onsite user study has two parts: static and dynamic. Eye tracking is used to monitor the gaze of the subjects. From our results we see that though Depth of Field does not act as a proper depth cue in all conditions, it can be used to reinforce the perception of which feature is in front of the other. The best results (high accuracy & fast response time) for correct perception of ordinal depth occurs when the front feature (out of the two features users were to choose from) is in focus and perspective projection is used. © 2013 IEEE.

  18. Field Test Design Simulations of Pore-Water Extraction for the SX Tank Farm

    Energy Technology Data Exchange (ETDEWEB)

    Truex, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Oostrom, Martinus [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-09-01

    A proof of principle test of pore water extraction is being performed by Washington River Protection Solutions for the U.S. Department of Energy, Office of River Protection. This test is being conducted to meet the requirements of Hanford Federal Facility Agreement and Consent Order (HFFACO) (Ecology et al. 1989) Milestone M 045-20, and is described in RPP-PLAN-53808, 200 West Area Tank Farms Interim Measures Investigation Work Plan. To support design of this test, numerical simulations were conducted to help define equipment and operational parameters. The modeling effort builds from information collected in laboratory studies and from field characterization information collected at the test site near the Hanford Site 241-SX Tank Farm. Numerical simulations were used to evaluate pore-water extraction performance as a function of the test site properties and for the type of extraction well configuration that can be constructed using the direct-push installation technique. Output of simulations included rates of water and soil-gas production as a function of operational conditions for use in supporting field equipment design. The simulations also investigated the impact of subsurface heterogeneities in sediment properties and moisture distribution on pore-water extraction performance. Phenomena near the extraction well were also investigated because of their importance for pore-water extraction performance.

  19. Low-cost, smartphone based frequency doubling technology visual field testing using virtual reality (Conference Presentation)

    Science.gov (United States)

    Alawa, Karam A.; Sayed, Mohamed; Arboleda, Alejandro; Durkee, Heather A.; Aguilar, Mariela C.; Lee, Richard K.

    2017-02-01

    Glaucoma is the leading cause of irreversible blindness worldwide. Due to its wide prevalence, effective screening tools are necessary. The purpose of this project is to design and evaluate a system that enables portable, cost effective, smartphone based visual field screening based on frequency doubling technology. The system is comprised of an Android smartphone to display frequency doubling stimuli and handle processing, a Bluetooth remote for user input, and a virtual reality headset to simulate the exam. The LG Nexus 5 smartphone and BoboVR Z3 virtual reality headset were used for their screen size and lens configuration, respectively. The system is capable of running the C-20, N-30, 24-2, and 30-2 testing patterns. Unlike the existing system, the smartphone FDT tests both eyes concurrently by showing the same background to both eyes but only displaying the stimulus to one eye at a time. Both the Humphrey Zeiss FDT and the smartphone FDT were tested on five subjects without a history of ocular disease with the C-20 testing pattern. The smartphone FDT successfully produced frequency doubling stimuli at the correct spatial and temporal frequency. Subjects could not tell which eye was being tested. All five subjects preferred the smartphone FDT to the Humphrey Zeiss FDT due to comfort and ease of use. The smartphone FDT is a low-cost, portable visual field screening device that can be used as a screening tool for glaucoma.

  20. Testing Chameleon Theories with Light Propagating through a Magnetic Field

    OpenAIRE

    Brax, P.; van de Bruck, C.; Davis, A. C.; Mota, D. F.; Shaw, D. J.

    2007-01-01

    It was recently argued that the observed PVLAS anomaly can be explained by chameleon field theories in which large deviations from Newton's law can be avoided. Here we present the predictions for the dichroism and the birefringence induced in the vacuum by a magnetic field in these models. We show that chameleon particles behave very differently from standard axion-like particles (ALPs). We find that, unlike ALPs, the chameleon particles are confined within the experimental set-up. As a conse...

  1. Stress Optical Coefficient, Test Methodology, and Glass Standard Evaluation

    Science.gov (United States)

    2016-05-01

    ARL-TN-0756 ● MAY 2016 US Army Research Laboratory Stress Optical Coefficient, Test Methodology , and Glass Standard Evaluation...Stress Optical Coefficient, Test Methodology , and Glass Standard Evaluation by Clayton M Weiss Oak Ridge Institute for Science and Education...ORISE), Belcamp, MD Parimal J Patel Weapons and Materials Research Directorate, ARL Approved for public release; distribution is

  2. Use of field experimental studies to evaluate emergency response models

    International Nuclear Information System (INIS)

    Gudiksen, P.H.; Lange, R.; Rodriguez, D.J.; Nasstrom, J.S.

    1985-01-01

    The three-dimensional diagnostic wind field model (MATHEW) and the particle-in-cell atmospheric transport and diffusion model (ADPIC) are used by the Atmospheric Release Advisory Capability to estimate the environmental consequences of accidental releases of radioactivity into the atmosphere. These models have undergone extensive evaluations against field experiments conducted in a variety of environmental settings ranging from relatively flat to very complex terrain areas. Simulations of tracer experiments conducted in a complex mountain valley setting revealed that 35 to 50% of the comparisons between calculated and measured tracer concentrations were within a factor of 5. This may be compared with a factor of 2 for 50% of the comparisons for relatively flat terrain. This degradation of results in complex terrain is due to a variety of factors such as the limited representativeness of measurements in complex terrain, the limited spatial resolution afforded by the models, and the turbulence parameterization based on sigma/sub theta/ measurements to evaluate the eddy diffusivities. Measurements of sigma/sub theta/ in complex terrain exceed those measured over flat terrain by a factor of 2 to 3 leading to eddy diffusivities that are unrealistically high. The results of model evaluations are very sensitive to the quality and the representativeness of the meteorological data. This is particularly true for measurements near the source. The capability of the models to simulate the dispersion of an instantaneously produced cloud of particulates was illustrated to be generally within a factor of 2 over flat terrain. 19 refs., 16 figs

  3. Improved field experimental designs and quantitative evaluation of aquatic ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    McKenzie, D.H.; Thomas, J.M.

    1984-05-01

    The paired-station concept and a log transformed analysis of variance were used as methods to evaluate zooplankton density data collected during five years at an electrical generation station on Lake Michigan. To discuss the example and the field design necessary for a valid statistical analysis, considerable background is provided on the questions of selecting (1) sampling station pairs, (2) experimentwise error rates for multi-species analyses, (3) levels of Type I and II error rates, (4) procedures for conducting the field monitoring program, and (5) a discussion of the consequences of violating statistical assumptions. Details for estimating sample sizes necessary to detect changes of a specified magnitude are included. Both statistical and biological problems with monitoring programs (as now conducted) are addressed; serial correlation of successive observations in the time series obtained was identified as one principal statistical difficulty. The procedure reduces this problem to a level where statistical methods can be used confidently. 27 references, 4 figures, 2 tables.

  4. Study on explosion field temperature testing system based on wireless data transmission

    International Nuclear Information System (INIS)

    Wang Xinling; Sun Yunqiang

    2011-01-01

    The accurate measurement of the transient temperature value produced by explosive blasting may provide the basis for distinguishing the types of the explosive, the power contrast of the explosive and the performance evaluation in the weapons research process. To solve the problems of the Universal Test System emplaced inconveniently and the stored testing system need to be recycled, it has designed the explosion field application in wireless sensor system of temperature measurement. The system based on PIC16F877A micro controller, CPLD complex programmable logic devices and nRF24L01 wireless transmission chip sensor. The system adopts the Tungsten-Rhenium Thermocouple as the temperature sensor, DS600 temperature sensor for cold temperature compensation. This system has arrangement convenient, high-speed data acquisition, trigger and working parameters of adjustable characteristics, has been successfully applied in a test system. (authors)

  5. Test facilities for evaluating nuclear thermal propulsion systems

    International Nuclear Information System (INIS)

    Beck, D.F.; Allen, G.C.; Shipers, L.R.; Dobranich, D.; Ottinger, C.A.; Harmon, C.D.; Fan, W.C.; Todosow, M.

    1992-01-01

    Interagency panels evaluating nuclear thermal propulsion (NTP) development options have consistently recognized the need for constructing a major new ground test facility to support fuel element and engine testing. This paper summarizes the requirements, configuration, and baseline performance of some of the major subsystems designed to support a proposed ground test complex for evaluating nuclear thermal propulsion fuel elements and engines being developed for the Space Nuclear Thermal Propulsion (SNTP) program. Some preliminary results of evaluating this facility for use in testing other NTP concepts are also summarized

  6. Fenestration System Performance Research, Testing, and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jim Benney

    2009-11-30

    The US DOE was and is instrumental to NFRC's beginning and its continued success. The 2005 to 2009 funding enables NFRC to continue expanding and create new, improved ratings procedures. Research funded by the US DOE enables increased fenestration energy rating accuracy. International harmonization efforts supported by the US DOE allow the US to be the global leader in fenestration energy ratings. Many other governments are working with the NFRC to share its experience and knowledge toward development of their own national fenestration rating process similar to the NFRC's. The broad and diverse membership composition of NFRC allows anyone with a fenestration interest to come forward with an idea or improvement to the entire fenestration community for consideration. The NFRC looks forward to the next several years of growth while remaining the nation's resource for fair, accurate, and credible fenestration product energy ratings. NFRC continues to improve its rating system by considering new research, methodologies, and expanding to include new fenestration products. Currently, NFRC is working towards attachment energy ratings. Attachments are blinds, shades, awnings, and overhangs. Attachments may enable a building to achieve significant energy savings. An NFRC rating will enable fair competition, a basis for code references, and a new ENERGY STAR product category. NFRC also is developing rating methods to consider non specular glazing such as fritted glass. Commercial applications frequently use fritted glazing, but no rating method exists. NFRC is testing new software that may enable this new rating and contribute further to energy conservation. Around the world, many nations are seeking new energy conservation methods and NFRC is poised to harmonize its rating system assisting these nations to better manage and conserve energy in buildings by using NFRC rated and labeled fenestration products. As this report has shown, much more work needs to be

  7. Superconducting magnet development capability of the LLNL [Lawrence Livermore National Laboratory] High Field Test Facility

    International Nuclear Information System (INIS)

    Miller, J.R.; Shen, S.; Summers, L.T.

    1990-02-01

    This paper discusses the following topics: High-Field Test Facility Equipment at LLNL; FENIX Magnet Facility; High-Field Test Facility (HFTF) 2-m Solenoid; Cryogenic Mechanical Test Facility; Electro-Mechanical Conductor Test Apparatus; Electro-Mechanical Wire Test Apparatus; FENIX/HFTF Data System and Network Topology; Helium Gas Management System (HGMS); Airco Helium Liquefier/Refrigerator; CTI 2800 Helium Liquefier; and MFTF-B/ITER Magnet Test Facility

  8. Evaluation of candidate geomagnetic field models for IGRF-12

    DEFF Research Database (Denmark)

    Thébault, Erwan; Finlay, Chris; Alken, Patrick

    2015-01-01

    Background: The 12th revision of the International Geomagnetic Reference Field (IGRF) was issued in December 2014 by the International Association of Geomagnetism and Aeronomy (IAGA) Division V Working Group V-MOD (http://www.ngdc.noaa.gov/IAGA/vmod/igrf.html). This revision comprises new spherical...... by the British Geological Survey (UK), DTU Space (Denmark), ISTerre (France), IZMIRAN (Russia), NOAA/NGDC (USA), GFZ Potsdam (Germany), NASA/GSFC (USA), IPGP (France), LPG Nantes (France), and ETH Zurich (Switzerland). Each candidate model was carefully evaluated and compared to all other models and a mean model...

  9. Joint use of laboratory bioassays and field-collected plants to evaluate toxicity and contaminant bioaccumulation

    International Nuclear Information System (INIS)

    Long, S.P.; Byron, E.R.; Ohlendorf, H.M.

    1995-01-01

    Soil toxicity tests using lettuce (Latuca saliva) were conducted using soil samples collected as part of ecological risk assessments at two facilities in California. At some sites, terrestrial plants were collected in the field for chemical analysis. Ecological concerns focused on exposures to plants, phytophagous insects, and their secondary consumers, such as birds and small mammals. The toxicity tests were used to assess potential exposures to a variety of site-specific contaminants including organochlorine pesticides, PCBs, PAHs, petroleum hydrocarbons, heavy metals, and other inorganic substances. Site soils were combined with clean control soils to produce toxicity test soil dilutions containing 100%, 75%, 50%, 25%, and 0% site soils. Observations of seed germination and growth were made at day 0, 7, 14, 21 and 28. Toxicity test results were combined with soil chemical analytical results and physical characteristics to establish NOAELs and LOAELs. Bioaccumulation in the lettuce and field-collected plants was evaluated by comparing plant contaminant to soil contaminant concentrations. Allometric equations and sublethal toxicity data were used to predict potential effects on birds and small mammals. Whole-body contaminant concentrations in insects collected on some of the plants in the field were also considered in evaluating the potential for toxicity to insectivorous birds. The study indicated that contaminant uptake was occurring in the field-collected and bioassay plants but not the insects. Site factors in addition to soil contaminant concentration influenced the potential for plant toxicity and bioaccumulation

  10. Field-testing of the ICHD-3 beta diagnostic criteria for classical trigeminal neuralgia

    DEFF Research Database (Denmark)

    Maarbjerg, Stine; Sørensen, Morten Togo; Gozalov, Aydin

    2015-01-01

    INTRODUCTION: We aimed to field-test the beta version of the third edition of the International Classification of Headache Disorders (ICHD-3 beta) diagnostic criteria for classical trigeminal neuralgia (TN). The proposed beta draft of the 11th version of the International Classification of Diseases...... (ICD-11 beta) is almost exclusively based on the ICHD-3 beta classification structure although slightly abbreviated. We compared sensitivity and specificity to ICHD-2 criteria, and evaluated the needs for revision. METHODS: Clinical characteristics were systematically and prospectively collected from...

  11. Field test of wireless sensor network in the nuclear environment

    International Nuclear Information System (INIS)

    Li, L.; Wang, Q.; Bari, A.; Deng, C.; Chen, D.; Jiang, J.; Alexander, Q.; Sur, B.

    2014-01-01

    Wireless sensor networks (WSNs) are appealing options for the health monitoring of nuclear power plants due to their low cost and flexibility. Before they can be used in highly regulated nuclear environments, their reliability in the nuclear environment and compatibility with existing devices have to be assessed. In situ electromagnetic interference tests, wireless signal propagation tests, and nuclear radiation hardness tests conducted on candidate WSN systems at AECL Chalk River Labs are presented. The results are favourable to WSN in nuclear applications. (author)

  12. Field test of wireless sensor network in the nuclear environment

    Energy Technology Data Exchange (ETDEWEB)

    Li, L., E-mail: lil@aecl.ca [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Wang, Q.; Bari, A. [Univ. of Western Ontario, London, Ontario (Canada); Deng, C.; Chen, D. [Univ. of Electronic Science and Technology of China, Chengdu, Sichuan (China); Jiang, J. [Univ. of Western Ontario, London, Ontario (Canada); Alexander, Q.; Sur, B. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    2014-06-15

    Wireless sensor networks (WSNs) are appealing options for the health monitoring of nuclear power plants due to their low cost and flexibility. Before they can be used in highly regulated nuclear environments, their reliability in the nuclear environment and compatibility with existing devices have to be assessed. In situ electromagnetic interference tests, wireless signal propagation tests, and nuclear radiation hardness tests conducted on candidate WSN systems at AECL Chalk River Labs are presented. The results are favourable to WSN in nuclear applications. (author)

  13. SMART operational field test evaluation : institutional issues report : final report

    Science.gov (United States)

    1997-06-01

    Implementation of Intelligent Transportation Systems (ITS) in Southeastern Michigan offers an opportunity to enhance public transit and increase regional mobility. However, the needs that ITS technology will be designed to meet, and the manner in whi...

  14. Development, Field Testing, and Evaluation of LIDAR Assisted Controls

    Energy Technology Data Exchange (ETDEWEB)

    Ehrmann, Robert [Asltom Power Inc.; Wang, Na [National Renewable Energy Lab. (NREL), Golden, CO (United States); Scholbrock, Andrew [National Renewable Energy Lab. (NREL), Golden, CO (United States); Guadayol, Marc [Alstom Power Inc.; Wright, Alan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Arora, Dhiraj [Alstom Power Inc.

    2015-05-18

    Typical wind turbines utilize feedback controllers which have a delayed response to winds peed disturbances. A nacelle mounted LIght Detection and Ranging(LIDAR) system measures a preview wind signal in front of the turbine. This can be included in a feed-forward control system, improving turbine pitch command for incoming variations in wind speed. The overall aim is reduced blade and tower fatigue, and potentially improved annual energy production. To be successful, the LIDAR must yield accurate wind speed measurements. Therefore, a LIDAR was characterized against a nearby met tower and turbine wind speed estimator. Results indicate good correlation between measurements.

  15. Cross-lingual tagger evaluation without test data

    DEFF Research Database (Denmark)

    Agic, Zeljko; Plank, Barbara; Søgaard, Anders

    2017-01-01

    We address the challenge of cross-lingual POS tagger evaluation in absence of manually annotated test data. We put forth and evaluate two dictionary-based metrics. On the tasks of accuracy prediction and system ranking, we reveal that these metrics are reliable enough to approximate test set-base......-based evaluation, and at the same time lean enough to support assessment for truly low-resource languages....

  16. Evaluation of LLTR series II test A-7 results

    International Nuclear Information System (INIS)

    Knittle, D.E.; Amos, J.C.; Yang, T.M.

    1981-09-01

    This report evaluates the test A-7 data and assesses the capability of the analytical methodology (as a result of Series I program) to predict the thermal/hydraulic phenomena associated with a large SWR event occurring after the sodium system pressure has increased to near the rupture disc burst pressure due to a smaller size leak event. Evaluation of intertest examination data to determine the extent of test article damage resulting from test A-7 is also included

  17. Test plan for FY-91 alpha CAM evaluation

    International Nuclear Information System (INIS)

    Winberg, M.R.

    1991-03-01

    This report describes the test plan for evaluating the Merlin Gerin, Inc., Edgar alpha continuous air monitor (CAM) and associated analysis system to be conducted by Idaho National Engineering Laboratory (INEL) for the Department of Energy. INEL has evaluated other commercial alpha CAM systems to detect transuranic contaminants during waste handling and retrieval operations. This test plan outlines experimental methods, sampling methods, sampling and analysis techniques, and equipment needed and safety and quality requirements to test the commercial CAM. 8 refs., 3 figs

  18. Exterior field evaluation of new generation video motion detection systems

    International Nuclear Information System (INIS)

    Malone, T.P.

    1988-01-01

    Recent advancements in video motion detection (VMD) system design and technology have resulted in several new commercial VMD systems. Considerable interest in the new VMD systems has been generated because the systems are advertised to work effectively in exterior applications. Previous VMD systems, when used in an exterior environment, tended to have very high nuisance alarm rates due to weather conditions, wildlife activity and lighting variations. The new VMD systems advertise more advanced processing of the incoming video signal which is aimed at rejecting exterior environmental nuisance alarm sources while maintaining a high detection capability. This paper discusses the results of field testing, in an exterior environment, of two new VMD systems

  19. Test-particle motion in Einstein's unified field theory. I. General theory and application to neutral test particles

    International Nuclear Information System (INIS)

    Johnson, C.R.

    1985-01-01

    We develop a method for finding the exact equations of structure and motion of multipole test particles in Einstein's unified field theory: the theory of the nonsymmetric field. The method is also applicable to Einstein's gravitational theory. Particles are represented by singularities in the field. The method is covariant at each step of the analysis. We also apply the method and find both in Einstein's unified field theory and in Einstein's gravitational theory the equations of structure and motion of neutral pole-dipole test particles possessing no electromagnetic multipole moments. In the case of Einstein's gravitational theory the results are the well-known equations of structure and motion of a neutral pole-dipole test particle in a given background gravitational field. In the case of Einstein's unified field theory the results are the same, providing we identify a certain symmetric second-rank tensor field appearing in Einstein's theory with the metric and gravitational field. We therefore discover not only the equations of structure and motion of a neutral test particle in Einstein's unified field theory, but we also discover what field in Einstein's theory plays the role of metric and gravitational field

  20. Workplace field testing of the pressure drop of particulate respirators using welding fumes.

    Science.gov (United States)

    Cho, Hyun-Woo; Yoon, Chung-Sik

    2012-10-01

    In a previous study, we concluded that respirator testing with a sodium chloride aerosol gave a conservative estimate of filter penetration for welding fume aerosols. A rapid increase in the pressure drop (PD) of some respirators was observed as fumes accumulated on the filters. The present study evaluated particulate respirator PD based on workplace field tests. A field PD tester was designed and validated using the TSI 8130 Automatic Filter Tester, designed in compliance with National Institute for Occupational and Safety and Health regulation 42 CFR part 84. Three models (two replaceable dual-type filters and one replaceable single-type filter) were evaluated against CO(2) gas arc welding on mild steel in confined booths in the workplace. Field tests were performed under four airborne concentrations (27.5, 15.4, 7.9, and 2.1 mg m(-3)). The mass concentration was measured by the gravimetric method, and number concentration was monitored using P-Trak (Model 8525, TSI, USA). Additionally, photos and scanning electron microscopy-energy dispersive X-ray spectroscopy were used to visualize and analyze the composition of welding fumes trapped in the filters. The field PD tester showed no significant difference compared with the TSI tester. There was no significant difference in the initial PD between laboratory and field results. The PD increased as a function of fume load on the respirator filters for all tested models. The increasing PD trend differed by models, and PD increased rapidly at high concentrations because greater amount of fumes accumulated on the filters in a given time. The increase in PD as a function of fume load on the filters showed a similar pattern as fume load varied for a particular model, but different patterns were observed for different models. Images and elemental analyses of fumes trapped on the respirator filters showed that most welding fumes were trapped within the first layer, outer web cover, and second layer, in order, while no fumes

  1. The German remote monitoring field test -- First results

    International Nuclear Information System (INIS)

    Richter, B.; Neumann, G.; Rudolf, K.; Schink, F.J.; Johnson, C.S.; Martinez, R.L.

    1996-01-01

    The International Atomic Energy Agency strives to increase the efficiency of its safeguards by reducing the inspection effort without losing safeguards effectiveness. Remote data transmission may have a potential to automate routine safeguards. The German government sponsors a field trial to study technical and non-technical issues related to the remote transmission of safeguards and status data as well as mailing-in of data carriers. Major technical issues of the field trial are the authenticity and confidentiality of the remotely received data as well as the reliability of the transmission techniques and data storage on removable data carriers. Non-technical issues are related to the release of data including the timing of data transmissions. The field trial takes place in the commercial Ahaus Dry Storage Facility for Spent Nuclear Fuel with participation of Sandia National Laboratories. The paper describes the first results

  2. Evaluation of abutment scour prediction equations with field data

    Science.gov (United States)

    Benedict, S.T.; Deshpande, N.; Aziz, N.M.

    2007-01-01

    The U.S. Geological Survey, in cooperation with FHWA, compared predicted abutment scour depths, computed with selected predictive equations, with field observations collected at 144 bridges in South Carolina and at eight bridges from the National Bridge Scour Database. Predictive equations published in the 4th edition of Evaluating Scour at Bridges (Hydraulic Engineering Circular 18) were used in this comparison, including the original Froehlich, the modified Froehlich, the Sturm, the Maryland, and the HIRE equations. The comparisons showed that most equations tended to provide conservative estimates of scour that at times were excessive (as large as 158 ft). Equations also produced underpredictions of scour, but with less frequency. Although the equations provide an important resource for evaluating abutment scour at bridges, the results of this investigation show the importance of using engineering judgment in conjunction with these equations.

  3. Photovoltaic performance models: an evaluation with actual field data

    Science.gov (United States)

    TamizhMani, Govindasamy; Ishioye, John-Paul; Voropayev, Arseniy; Kang, Yi

    2008-08-01

    Prediction of energy production is crucial to the design and installation of the building integrated photovoltaic systems. This prediction should be attainable based on the commonly available parameters such as system size, orientation and tilt angle. Several commercially available as well as free downloadable software tools exist to predict energy production. Six software models have been evaluated in this study and they are: PV Watts, PVsyst, MAUI, Clean Power Estimator, Solar Advisor Model (SAM) and RETScreen. This evaluation has been done by comparing the monthly, seasonaly and annually predicted data with the actual, field data obtained over a year period on a large number of residential PV systems ranging between 2 and 3 kWdc. All the systems are located in Arizona, within the Phoenix metropolitan area which lies at latitude 33° North, and longitude 112 West, and are all connected to the electrical grid.

  4. Intervening to decrease the probability of alcohol-impaired driving: Impact of novel field sobriety tests.

    Science.gov (United States)

    Smith, Ryan C; Robinson, Zechariah; Bazdar, Alexandra; Geller, E Scott

    2016-01-01

    The efficacy of novel field sobriety tests to predict breath alcohol content (BAC) and perceptions of driving risk was evaluated. Participants (N = 210) were passersby at two downtown locations near local bars and one on-campus location near a late-night dining facility between the hours of 10:00 p.m. and 2:00 a.m. Participants gave ratings of their perceived risk to drive at their current level of intoxication, then completed three sobriety tests (a hand-pat, tracing test, and Romberg test), and finally provided new ratings of their perceived risk to drive. After completing the final set of questions, participants were administered a Lifeloc FC20 breath alcohol test (±.005 g/dL). Each of the sobriety tests performed better than chance at predicting participant intoxication, but the performance feedback did not enhance awareness of one's risk to drive at a given BAC. Actually, after the sobriety tests, Greek-life females perceived themselves to be less at-risk to drive.

  5. Evaluation of the finger wrinkling test: A pilot study

    NARCIS (Netherlands)

    van Barneveld, S.; van der Palen, Jacobus Adrianus Maria; van Putten, Michel Johannes Antonius Maria

    2010-01-01

    Purpose: Tilt table testing mainly evaluates the systemic cardiovascular part of the autonomic nervous system, while it is assumed that the finger wrinkling test assesses the peripheral part of the autonomic nervous system. In this study we explored whether the finger wrinkling test could be a

  6. Testing chameleon theories with light propagating through a magnetic field

    International Nuclear Information System (INIS)

    Brax, Philippe; Bruck, Carsten van de; Davis, Anne-Christine; Mota, David F.; Shaw, Douglas

    2007-01-01

    It was recently argued that the observed PVLAS anomaly can be explained by chameleon field theories in which large deviations from Newton's law can be avoided. Here we present the predictions for the dichroism and the birefringence induced in the vacuum by a magnetic field in these models. We show that chameleon particles behave very differently from standard axionlike particles (ALPs). We find that, unlike ALPs, the chameleon particles are confined within the experimental setup. As a consequence, the birefringence is always bigger than the dichroism in PVLAS-type experiments

  7. The Evaluation of Diagnostic Tests for Sexually Transmitted Infections

    Directory of Open Access Journals (Sweden)

    Max A Chernesky

    2005-01-01

    Full Text Available Diagnostic tests should receive method- and use-effectiveness evaluations. Method-effectiveness evaluations determine sensitivity, specificity and predictive values for new tests. Use-effectiveness evaluations determine how practical or convenient a new test will be in a specific setting and may not be performed in a formal way in North American laboratories. To perform a clinical method evaluation of diagnostic tests, a good relationship between laboratory and clinical personnel is essential. Studies are usually conducted separately on populations of men and women, and should include sampling from different prevalence groups. Test performance comparisons may be made on a single specimen type or on more than one specimen from the same patient, which allows for the expansion of a reference standard and includes the ability of a particular assay, performed on a specimen type to diagnose an infected individual. The following components of the evaluation should be standardized and carefully followed: specimen identification; collection; transportation; processing; quality control; reading; proficiency testing; confirmatory testing; discordant analysis -- sensitivity, specificity and predictive value calculations; and record keeping. Methods are available to determine whether sample results are true or false positives or negatives. Use-effectiveness evaluations might determine the stability or durability of supplies and equipment; the logistics of shipping, receiving and storing supplies; the clarity and completeness of test instructions; the time and effort required to process and read results; the subjectivity factors in interpretation and reporting; and the costs. These determinations are usually more apparent for commercial assays than for homemade tests.

  8. A Field Test for Upper Body Strength and Endurance.

    Science.gov (United States)

    Nelson, Jack K.; And Others

    1991-01-01

    Researchers studied the reliability of the modified push-up test in measuring upper body strength and endurance in elementary through college students. It also examined the accuracy of partner scoring. The test proved much easier to administer than the regular floor push-up. It was valid and reliable for all students and suitable for partner…

  9. Optical Automatic Car Identification (OACI) Field Test Program

    Science.gov (United States)

    1976-05-01

    The results of the Optical Automatic Car Identification (OACI) tests at Chicago conducted from August 16 to September 4, 1975 are presented. The main purpose of this test was to determine the suitability of optics as a principle of operation for an a...

  10. Final report of the Buffer Mass Test - Volume I: Scope, preparative field work and test arrangement

    International Nuclear Information System (INIS)

    Pusch, R.; Nilsson, J.; Ramqvist, G.

    1985-07-01

    The Buffer Mass Test was conducted in a 30 m long drift at 340 m depth in the Stripa mine, The main objective being to check the predicted functions of certain bentonite-based buffer materials in rock environment. These materials were blocks of highly compacted sodium bentonite placed in large boreholes simulating deposition holes for canisters, and on-site compacted sand/bentonite mixtures used as tunnel backfill. The blocks of bentonite embedded electrical heaters which served to produce heat so as to create conditions similar to those in a repository. The temperature in the initially non-saturated buffer materials was expected to be a function of the water uptake from the rock, which was also assumed to lead to rather high swelling pressures. The recording of these processes and of the moistening of the buffer materials , as well as of the associated build-up of piezometric heads at rock/buffer interfaces, was the major item of the field test. For this purpose the buffer materials and the rock were equipped with a large number of thermal elements, pressure and piezometric cells as well as moisture sensors. The choise of positions and properties of these gauges, which were connected to an effective data acquisition system, was based on predictions that required a careful site documentation with respect to the fracture characteristics and hydrological properties of the surrounding rock. (author)

  11. Field Lysimeter Test Facility: Protective barrier test results (FY 1990, the third year)

    International Nuclear Information System (INIS)

    Campbell, M.D.; Gee, G.W.

    1990-11-01

    The Field Lysimeter Test Facility (FLTF) was constructed to test protective barriers for isolating low-level radioactive and hazardous wastes from the biosphere. Protective barriers are specially configured earth materials placed over near-surface wastes to prevent intrusion of water, plants, and animals. Low-level radioactive waste is stored in near-surface repositories at the Hanford Site and can be transported into the biosphere by water, plants, and animals. The purpose of the FLTF is to measure water balance within barriers as precipitation is partitioned to evaporation (including transpiration), storage, and drainage. Runoff was prevented by raised edges on the lysimeters. Water balance in protective barriers depends on the water-holding capacity of the soil, the gradient of a potential, and the conductivity of the underlying capillary barrier. Current barrier design uses soil with a high water storage capacity and a capillary barrier underlying the soil to increase its water storage capacity. This increased storage capacity is to hold water, which would normally drain, near the the surface where evaporation can cycle it back to the atmosphere. 7 refs., 23 figs., 5 tabs

  12. Visual Field Measurement with Motion Sensitivity Screening Test in ...

    African Journals Online (AJOL)

    Eye disease is a frequent complication of onchocerciasis in countrise where the disease is highly endemic. It has been shown that early ocular lesions which manifest as visual field defects or reduction in visual acuity can be reversed following treatment with ivermectin. At the community level, it is important to detect ...

  13. Translating laboratory compaction test results to field scale

    NARCIS (Netherlands)

    Roholl, J.A.; Thienen-Visser, K. van; Breunese, J.N.

    2016-01-01

    In recent studies on the surface subsidence caused by hydrocarbon recovery of the Groningen gas field, the predicted subsidence is overestimated if results of compaction experiments are not corrected by an empirical `upscaling factor'. In order to find an explanation for this `upscaling factor', an

  14. Discriminative deep inelastic tests of strong interaction field theories

    International Nuclear Information System (INIS)

    Glueck, M.; Reya, E.

    1979-02-01

    It is demonstrated that recent measurements of ∫ 0 1 F 2 (x, Q 2 )dx eliminate already all strong interaction field theories except QCD. A detailed study of scaling violations of F 2 (x, Q 2 ) in QCD shows their insensitivity to the gluon content of the hadron at presently measured values of Q 2 . (orig.) [de

  15. Performance Evaluation Of Furrow Lengths And Field Application Techniques

    Directory of Open Access Journals (Sweden)

    Issaka

    2015-08-01

    Full Text Available Abstract The study evaluated performance of furrow lengths and field application techniques. The experiment was conducted on 2000 m2 field at Bontanga irrigation scheme. Randomized Complete Block Design RCBD was used with three replicates. The replicates include Blocks A B and C of furrow lengths 100 m 75 m and 50 m respectively. Each replicate had surge cut-off cut-back and bunds treatments. Water was introduced into the furrows and the advance distances and time were measured. Results of the study showed that at Block A surge technique recorded the highest advance rate of 1.26 minm and opportunity time of 11 min whilst bunds recorded the lowest advance rate of 0.92 minm. Significant difference 3.32 pamp88050.05 occurred between treatment means of field application techniques at Block A 100 m. Significant difference 2.71 pamp88050.05 was also recorded between treatment means. At Block B 75 m there was significant difference 2.71 pamp88050.05 between treatment means. No significant difference 0.14 pamp88040.05 was observed among surge cut-back and bunds techniques. There was significant difference 2.60 pamp88050.05 between treatment means but no significant difference between cut-back and bunds techniques in Block C 50 m. Their performance was ranked in the order Surge Cut-back Cut-off Bunds for furrow lengths 100 m 75 m and 50 m respectively.

  16. Football helmet drop tests on different fields using an instrumented Hybrid III head.

    Science.gov (United States)

    Viano, David C; Withnall, Chris; Wonnacott, Michael

    2012-01-01

    An instrumented Hybrid III head was placed in a Schutt ION 4D football helmet and dropped on different turfs to study field types and temperature on head responses. The head was dropped 0.91 and 1.83 m giving impacts of 4.2 and 6.0 m/s on nine different football fields (natural, Astroplay, Fieldturf, or Gameday turfs) at turf temperatures of -2.7 to 23.9 °C. Six repeat tests were conducted for each surface at 0.3 m (1') intervals. The Hybrid III was instrumented with triaxial accelerometers to determine head responses for the different playing surfaces. For the 0.91-m drops, peak head acceleration varied from 63.3 to 117.1 g and HIC(15) from 195 to 478 with the different playing surfaces. The lowest response was with Astroplay, followed by the engineered natural turf. Gameday and Fieldturf involved higher responses. The differences between surfaces decreased in the 1.83 m tests. The cold weather testing involved higher accelerations, HIC(15) and delta V for each surface. The helmet drop test used in this study provides a simple and convenient means of evaluating the compliance and energy absorption of football playing surfaces. The type and temperature of the playing surface influence head responses.

  17. Study on the system development for evaluating long-term alteration of hydraulic field in Near Field 2

    International Nuclear Information System (INIS)

    Okutu, Kazuo; Morikawa, Seiji; Takamura, Hisashi

    2003-02-01

    For the high performance evaluation of reliability of TRU waste repository, the system development for evaluating long-term alteration in consideration of the changes action of barrier materials of hydraulic field in Near Field is required. In this research, the system development for evaluating long-term alteration of hydraulic field in Near Field was examined. The model evaluating each phenomena and the prototype system for chemical/mechanical analysis system were developed, and the method of coupling chemical with dynamic analysis was examined. To improve accuracy and propriety of this analysis system in the future, necessary development elements were arranged. The research result of this year is shown below. 1) Knowledge concerning the chemical phenomena in the near field evolution was rearranged. Experimental approaches and analysis methods were applied to the phenomena of which the knowledge can be obtained. Approaches to focus the model were applied to the phenomena for which knowledge is essentially difficult to obtain. The analysis model was improved using knowledge from natural analog and computational analyses. An analysis system was developed and the propriety of the model was demonstrated. 2) The model of bentonite material was developed by focusing attention on nonlinear swelling behavior. And the model of cement material was developed by focusing attention on deformation behavior influenced by leaching of calcium element which cause reducing of rigidity and strength. With regard to the bentonite model, to testify its propriety, the trial analysis result compared with the consolidation properties test data. Furthermore, the dynamic alteration action analysis system consisted of bentonite and cement model was developed, and trial analysis was performed. In this trial analysis, parameters of cation exchange ratio of Na-bentonite for Ca ion and leaching ratio of Ca from cement material were considered. On the one hand, as concerns rock, to include the

  18. Field Tests with Drilled Shafts in Tension in Frictional Soil

    DEFF Research Database (Denmark)

    Krabbenhøft, Sven; Damkilde, Lars; Andersen, Allan

    2009-01-01

    Three series of ten piles each have been installed. The lengths of the piles varied from 2 m to 6 m and the diameters were 14 cm, 25 cm and 60 cm. The piles were constructed above the ground water table using continuous flight augers and the concrete was placed by gravity free fall. All piles were...... tested to failure in axial uplift and the load-displacement relations were recorded and the results from the tests have been compared with theoretical values based on current design practice and the methods proposed by Fleming et al. and Reese & O'Neill seem to produce the best match with the test...

  19. Consensus on Intermediate Scale Salt Field Test Design

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlman, Kristopher L; Mills, Melissa Marie; Matteo, Edward N

    2017-03-01

    This report summarizes the first stage in a collaborative effort by Sandia, Los Alamos, and Lawrence Berkeley National Laboratories to design a small-diameter borehole heater test in salt at the Waste Isolation Pilot Plant (WIPP) for the US Department of Energy Office of Nuclear Energy (DOE-NE). The intention is to complete test design during the remainder of fiscal year 2017 (FY17), and the implementation of the test will begin in FY18. This document is the result of regular meetings between the three national labs and the DOE-NE, and is intended to represent a consensus of these meetings and discussions.

  20. Preliminary field evaluation of high efficiency steel filters

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, W.; Larsen, G.; Lopez, R. [Lawrence Livermore National Laboratory, CA (United States)] [and others

    1995-02-01

    We have conducted an evaluation of two high efficiency steel filters in the exhaust of an uranium oxide grit blaster at the Y-12 Plant in Oak Ridge Tennessee. The filters were installed in a specially designed filter housing with a reverse air-pulse cleaning system for automatically cleaning the filters in-place. Previous tests conducted on the same filters and housing at LLNL under controlled conditions using Arizona road dust showed good cleanability with reverse air pulses. Two high efficiency steel filters, containing 64 pleated cartridge elements housed in the standard 2` x 2` x 1` HEPA frame, were evaluated in the filter test housing using a 1,000 cfm slip stream containing a high concentration of depleted uranium oxide dust. One filter had the pleated cartridges manufactured to our specifications by the Pall Corporation and the other by Memtec Corporation. Test results showed both filters had a rapid increase in pressure drop with time, and reverse air pulses could not decrease the pressure drop. We suspected moisture accumulation in the filters was the problem since there were heavy rains during the evaluations, and the pressure drop of the Memtec filter decreased dramatically after passing clean, dry air through the filter and after the filter sat idle for one week. Subsequent laboratory tests on a single filter cartridge confirmed that water accumulation in the filter was responsible for the increase in filter pressure drop and the inability to lower the pressure drop by reverse air pulses. No effort was made to identify the source of the water accumulation and correct the problem because the available funds were exhausted.

  1. Evaluation of the residual stress field in a steam generator end tube after hydraulic expansion

    International Nuclear Information System (INIS)

    Thiel, F.; Kang, S.; Chabrerie, J.

    1994-01-01

    This paper presents a finite element elastoplastic model of a nuclear steam generator end tube, used to evaluate the residual stress field existing after hydraulic expansion of the tube into the tubesheet of the heat exchanger. This model has been tested against an experimental hydraulic expansion, carried out on full scale end tubes. The operation was monitored thanks to strain gages localized on the outer surface of the tubes, subjected to elastoplastic deformations. After a presentation of the expansion test and the description of the numerical model, the authors compare the stress fields issues from the gages and from the model. The comparison shows a good agreement. These results allow them to calculate the stress field resulting from normal operating conditions, while taking into account a correct initial state of stress. Therefore the authors can improve the understanding of the behavior of a steam generator end tube, with respect to stress corrosion cracking and crack growth

  2. SMART Wind Turbine Rotor: Design and Field Test

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Jonathan C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Resor, Brian R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Paquette, Joshua A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); White, Jonathan R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-01-29

    This report documents the design, fabrication, and testing of the SMART Rotor. This work established hypothetical approaches for integrating active aerodynamic devices (AADs) into the wind turbine structure and controllers.

  3. Simulated Field Trials Using an Indoor Aerosol Test Chamber

    National Research Council Canada - National Science Library

    Semler, D. D; Roth, A. P; Semler, K. A; Nolan, P. M

    2004-01-01

    .... In this method, the aerosol chamber control software manipulates circulation fan speeds, chamber vacuum and agent spray times to produce a simulated dynamic cloud within the aerosol test chamber...

  4. Simulated Field Trials Using An Indoor Aerosol Test Chamber

    National Research Council Canada - National Science Library

    Semler, D. D; Roth, A. P; Semler, K. A; Nolan, P. M

    2004-01-01

    .... In this method, the aerosol chamber control software manipulates circulation fan speeds, chamber vacuum and agent spray times to produce a simulated dynamic cloud within the aerosol test chamber...

  5. A study of statistical tests for near-real-time materials accountancy using field test data of Tokai reprocessing plant

    International Nuclear Information System (INIS)

    Ihara, Hitoshi; Nishimura, Hideo; Ikawa, Koji; Miura, Nobuyuki; Iwanaga, Masayuki; Kusano, Toshitsugu.

    1988-03-01

    An Near-Real-Time Materials Accountancy(NRTA) system had been developed as an advanced safeguards measure for PNC Tokai Reprocessing Plant; a minicomputer system for NRTA data processing was designed and constructed. A full scale field test was carried out as a JASPAS(Japan Support Program for Agency Safeguards) project with the Agency's participation and the NRTA data processing system was used. Using this field test data, investigation of the detection power of a statistical test under real circumstances was carried out for five statistical tests, i.e., a significance test of MUF, CUMUF test, average loss test, MUF residual test and Page's test on MUF residuals. The result shows that the CUMUF test, average loss test, MUF residual test and the Page's test on MUF residual test are useful to detect a significant loss or diversion. An unmeasured inventory estimation model for the PNC reprocessing plant was developed in this study. Using this model, the field test data from the C-1 to 85 - 2 campaigns were re-analyzed. (author)

  6. Multifocal electroretinogram and central visual field testing in central areolar choroidal dystrophy.

    Science.gov (United States)

    Gundogan, Fatih Cakir; Dinç, Umut Asli; Erdem, Uzeyir; Ozge, Gokhan; Sobaci, Gungor

    2010-01-01

    To study multifocal electroretinogram (mfERG) and its relation to retinal sensitivity assessed by Humphrey visual field (HVF) analysis in central areolar choroidal dystrophy (CACD). Seven eyes of 4 patients with CACD and 15 normal control subjects were examined. mfERG and central 30/2 HVF were tested for each participant. Ring analysis in mfERG was evaluated. HVF results were evaluated in 5 concentric rings in order to compare the results to concentric ring analysis in mfERG. The differences between control subjects and patients were evaluated by Mann-Whitney U test and the correlations were assessed by Spearman test. Mean Snellen acuity was 0.49+/-0.10 in patients. HVF revealed central scotoma in 6 of 7 eyes (85.7%), whereas a paracentral scotoma extending to fixation point was detected in 1 eye. The retinal sensitivities in 5 concentric rings in HVF were significantly lower (p<0.001 for ring 1 to ring 4, and p=0.017 in ring 5) in CACD patients. Similarly, CACD patients had lower P1/N1 amplitudes (p<0.05) and delayed P1/N1 implicit times (p<0.05). In CACD, in the areas of scotoma detected by HVF, mfERG values were depressed. However, both mfERG and HVF abnormalities were found outside the areas of ophthalmoscopically normal retinal areas.

  7. Sound field control for a low-frequency test facility

    DEFF Research Database (Denmark)

    Pedersen, Christian Sejer; Møller, Henrik

    2013-01-01

    The two largest problems in controlling the reproduction of low-frequency sound for psychoacoustic experiments is the effect of the room due to standing waves and the relatively large sound pressure levels needed. Anechoic rooms are limited downward in frequency and distortion may be a problem even...... at moderate levels, while pressure-field playback can give higher sound pressures but is limited upwards in frequency. A new solution that addresses both problems has been implemented in the laboratory of Acoustics, Aalborg University. The solution uses one wall with 20 loudspeakers to generate a plane wave...... that is actively absorbed when it reaches the 20 loudspeakers on the opposing wall. This gives a homogeneous sound field in the majority of the room with a flat frequency response in the frequency range 2-300 Hz. The lowest frequencies are limited to sound pressure levels in the order of 95 dB. If larger levels...

  8. Field Test of the World Health Organization Multi-Professional Patient Safety Curriculum Guide

    Science.gov (United States)

    Farley, Donna; Zheng, Hao; Rousi, Eirini; Leotsakos, Agnès

    2015-01-01

    Introduction Although the importance of training in patient safety has been acknowledged for over a decade, it remains under-utilized and under-valued in most countries. WHO developed the Multi-professional Patient Safety Curriculum Guide to provide schools with the requirements and tools for incorporating patient safety in education. It was field tested with 12 participating schools across the six WHO regions, to assess its effectiveness for teaching patient safety to undergraduate and graduate students in a global variety of settings. Methods The evaluation used a combined prospective/retrospective design to generate formative information on the experiences of working with the Guide and summative information on the impacts of the Guide. Using stakeholder interviews and student surveys, data were gathered from each participating school at three times: the start of the field test (baseline), soon after each school started teaching, and soon after each school finished teaching. Results Stakeholders interviewed were strongly positive about the Guide, noting that it emphasized universally important patient safety topics, was culturally appropriate for their countries, and gave credibility and created a focus on patient safety at their schools. Student perceptions and attitudes regarding patient safety improved substantially during the field test, and their knowledge of the topics they were taught doubled, from 10.7% to 20.8% of correct answers on the student survey. Discussion This evaluation documented the effectiveness of the Curriculum Guide, for both ease of use by schools and its impacts on improving the patient safety knowledge of healthcare students. WHO should be well positioned to refine the contents of the Guide and move forward in encouraging broader use of the Guide globally for teaching patient safety. PMID:26406893

  9. Field Test of the World Health Organization Multi-Professional Patient Safety Curriculum Guide.

    Science.gov (United States)

    Farley, Donna; Zheng, Hao; Rousi, Eirini; Leotsakos, Agnès

    2015-01-01

    Although the importance of training in patient safety has been acknowledged for over a decade, it remains under-utilized and under-valued in most countries. WHO developed the Multi-professional Patient Safety Curriculum Guide to provide schools with the requirements and tools for incorporating patient safety in education. It was field tested with 12 participating schools across the six WHO regions, to assess its effectiveness for teaching patient safety to undergraduate and graduate students in a global variety of settings. The evaluation used a combined prospective/retrospective design to generate formative information on the experiences of working with the Guide and summative information on the impacts of the Guide. Using stakeholder interviews and student surveys, data were gathered from each participating school at three times: the start of the field test (baseline), soon after each school started teaching, and soon after each school finished teaching. Stakeholders interviewed were strongly positive about the Guide, noting that it emphasized universally important patient safety topics, was culturally appropriate for their countries, and gave credibility and created a focus on patient safety at their schools. Student perceptions and attitudes regarding patient safety improved substantially during the field test, and their knowledge of the topics they were taught doubled, from 10.7% to 20.8% of correct answers on the student survey. This evaluation documented the effectiveness of the Curriculum Guide, for both ease of use by schools and its impacts on improving the patient safety knowledge of healthcare students. WHO should be well positioned to refine the contents of the Guide and move forward in encouraging broader use of the Guide globally for teaching patient safety.

  10. A semi-field approach to testing effects of fresh pesticide residues on bees in multiple-rate test

    NARCIS (Netherlands)

    Bakker, F.; Calis, J.N.M.

    2003-01-01

    We describe a semi-field cage test specifically designed to test effects of delayed exposure to plant protection products. The trial involved the use of standardised mini-beehives. The principle of the trial was to prepare two groups of potted test plants per treatment. The first group of plants

  11. Evaluation of Alternative Field Buses for Lighting ControlApplications

    Energy Technology Data Exchange (ETDEWEB)

    Koch, Ed; Rubinstein, Francis

    2005-03-21

    The Subcontract Statement of Work consists of two major tasks. This report is the Final Report in fulfillment of the contract deliverable for Task 1. The purpose of Task 1 was to evaluate existing and emerging protocols and standards for interfacing sensors and controllers for communicating with integrated lighting control systems in commercial buildings. The detailed task description follows: Task 1. Evaluate alternative sensor/field buses. The objective of this task is to evaluate existing and emerging standards for interfacing sensors and controllers for communicating with integrated lighting control systems in commercial buildings. The protocols to be evaluated will include at least: (1) 1-Wire Net, (2) DALI, (3) MODBUS (or appropriate substitute such as EIB) and (4) ZigBee. The evaluation will include a comparative matrix for comparing the technical performance features of the different alternative systems. The performance features to be considered include: (1) directionality and network speed, (2) error control, (3) latency times, (4) allowable cable voltage drop, (5) topology, and (6) polarization. Specifically, Subcontractor will: (1) Analyze the proposed network architecture and identify potential problems that may require further research and specification. (2) Help identify and specify additional software and hardware components that may be required for the communications network to operate properly. (3) Identify areas of the architecture that can benefit from existing standards and technology and enumerate those standards and technologies. (4) Identify existing companies that may have relevant technology that can be applied to this research. (5) Help determine if new standards or technologies need to be developed.

  12. Field study evaluation of diffuse ceiling ventilation in classroom during real operating conditions

    DEFF Research Database (Denmark)

    Kristensen, Martin Heine; Jensen, Jakob Søland; Heiselberg, Per Kvols

    2017-01-01

    Highlights •Field experimental measurements during real operating conditions. •Evaluation of pressure chamber effect. •Evaluation of displacement effect. •Evaluation of thermal comfort.......Highlights •Field experimental measurements during real operating conditions. •Evaluation of pressure chamber effect. •Evaluation of displacement effect. •Evaluation of thermal comfort....

  13. HOTSPOT, Field Evaluation of Radiation Release from Nuclear Accident

    International Nuclear Information System (INIS)

    2001-01-01

    1 - Description of program or function: The HOTSPOT Health Physics codes were created to provide Health Physics personnel with a fast, field-portable calculational tool for evaluating accidents involving radioactive materials. HOTSPOT codes are a first-order approximation of the radiation effects associated with the atmospheric release of radioactive materials. HOTSPOT programs are reasonably accurate for a timely initial assessment. More importantly, HOTSPOT codes produce a consistent output for the same input assumptions and minimize the probability of errors associated with reading a graph incorrectly or scaling a universal nomogram during an emergency. Four general programs, PLUME, EXPLOSION, FIRE, and RESUSPENSION, calculate a downwind assessment following the release of radioactive material resulting from a continuous or puff release, explosive release, fuel fire, or an area contamination event. Other programs deal with the release of plutonium, uranium, and tritium to expedite an initial assessment of accidents involving nuclear weapons. Additional programs estimate the dose commitment from inhalation of any one of the radionuclides listed in the database of radionuclides, calibrate a radiation survey instrument for ground survey measurements, and screening of plutonium uptake in the lung. The HOTSPOT codes are fast, portable, easy to use, and fully documented. HOTSPOT supports color high resolution monitors and printers for concentration plots and contours. The codes have been extensively used by the DOS community since 1985. Version 8 allows users to add their own custom radionuclide library and to create custom radionuclide mixtures. It also includes wet deposition to approximate the enhanced plume depletion and ground deposition due to the effects of rain. Additional release geometry options for TRITIUM RELEASE and GENERAL PLUME were added, as well as several other enhancements and improvements. See info (f1) from the main HOTSPOT menu for additional

  14. Effect of interleukin-1beta on the behavior of rats during mild stress in the open-field test.

    Science.gov (United States)

    Pertsov, S S; Koplik, E V; Simbirtsev, A S; Kalinichenko, L S

    2009-11-01

    We studied the effect of interleukin-1beta on the behavior of rats with different individual typological characteristics during mild stress in the open-field test. Intraperitoneal injection of interleukin-1beta (5 microg/kg, 108 U/mg) was followed by a decrease in orientation and exploratory activity of passive and, particularly, of active animals in the open field. As differentiated from rats receiving physiological saline, the initial differences in behavioral characteristics of active and passive animals were not revealed in the repeated test after injection of interleukin-1beta. We conclude that interleukin-1beta abolishes the behavioral differences between active and passive specimens in the open field. These data suggest that administration of interleukin-1beta to rats leads to reorganization of the mechanisms for emotional evaluation of adverse emotiogenic factors under conditions of mild stress in the open-field test.

  15. A Field Performance Evaluation Scheme for Microwave-Absorbing Material Coatings

    Directory of Open Access Journals (Sweden)

    Shaopeng Guan

    2017-03-01

    Full Text Available Performance evaluation is an important aspect in the study of microwave-absorbing material coatings. The reflectivity of the incident wave is usually taken as the performance indicator. There have been various methods to directly or indirectly measure the reflectivity, but existing methods are mostly cumbersome and require a strict testing environment. What is more, they cannot be applied to field measurement. In this paper, we propose a scheme to achieve field performance evaluation of microwave-absorbing materials, which adopts a small H-plane sectoral horn antenna as the testing probe and a small microwave reflectometer as the indicator. When the size of the H-plane sectoral horn antenna is specially designed, the field distribution at the antenna aperture can be approximated as a plane wave similar to the far field of the microwave emitted by a radar unit. Therefore, the reflectivity can be obtained by a near-field measurement. We conducted experiments on a kind of ferrite-based microwave-absorbing material at X band (8.2–12.4 GHz to validate the scheme. The experimental results show that the reflectivity is in agreement with the reference data measured by the conventional method as a whole.

  16. Hydra phantom applicability for carrying out tests of field uniformity in gamma cameras

    International Nuclear Information System (INIS)

    Aragao Filho, Geraldo L.; Oliveira, Alex C.H.

    2014-01-01

    Nuclear Medicine is a medical modality that makes use of radioactive material 'in vivo' in humans, making them a temporary radioactive source. The radiation emitted by the patient's body is detected by a specific equipment, called a gamma camera, creates an image showing the spatial and temporal biodistribution of radioactive material administered to the patient. Therefore, it's of fundamental importance a number of specific measures to make sure that procedure be satisfactory, called quality control. To Nuclear Medicine, quality control of gamma camera has the purpose of ensuring accurate scintillographic imaging, truthful and reliable for the diagnosis, guaranteeing visibility and clarity of details of structures, and also to determine the frequency and the need for preventive maintenance of equipment. To ensure the quality control of the gamma camera it's necessary to use some simulators, called phantom, used in Nuclear Medicine to evaluate system performance, system calibration and simulation of injuries. The goal of this study was to validate a new simulator for nuclear medicine, the Hydra phantom. The phantom was initially built for construction of calibration curves used in radiotherapy planning and quality control in CT. It has similar characteristics to specific phantoms in nuclear medicine, containing inserts and water area. Those inserts are regionally sourced materials, many of them are already used in the literature and based on information about density and interaction of radiation with matter. To verify its efficiency in quality control in Nuclear Medicine, was performed a test for uniformity field, one of the main tests performed daily, so we can verify the ability of the gamma camera to reproduce a uniform distribution of the administered activity in the phantom, been analysed qualitatively, through the image, and quantitatively, through values established for Central Field Of View (CFOV) and Useful Field Of View (UFOV). Also, was evaluated their

  17. The Motivation Analysis Test: an historical and contemporary evaluation.

    Science.gov (United States)

    Bernard, Larry C; Walsh, R Patricia; Mills, Michael

    2005-04-01

    This is an historical review and contemporary empirical evaluation of the Motivation Analysis Test (MAT), one of the first tests to take a psychometric approach to the assessment of motivation. Reviews were quite positive, but the test is now over 50 years old. Nevertheless, it employs innovations in measurement not widely used in objective measurement then or now: (1) subtests with different formats, (2) disguised items, (3) speeded administration procedures, and (4) ipsative format and scoring procedures. These issues are discussed and a contemporary sample (N = 360) obtained to evaluate the Motivation Analysis Test in light of its innovative characteristics.

  18. A rapidly equilibrating, thin film, passive water sampler for organic contaminants; characterization and field testing

    Energy Technology Data Exchange (ETDEWEB)

    St George, Tiffany [Department of Marine Science, University of Connecticut, 1080 Shennecossett Road, Groton, CT 06340 (United States); Department of Science, United States Coast Guard Academy, 27 Mohegan Ave., New London, CT 06320 (United States); Vlahos, Penny, E-mail: penny.vlahos@uconn.ed [Department of Chemistry, University of Connecticut, 55 Eagleville Road, Storrs, CT 06269 (United States); Department of Marine Science, University of Connecticut, 1080 Shennecossett Road, Groton, CT 06340 (United States); Harner, Tom [Science and Technology Branch, Environment Canada, 4905 Dufferin Street, Toronto, Ontario M3H 5T4 (Canada); Helm, Paul [Environmental Monitoring and Reporting Branch, Ontario Ministry of the Environment, 125 Resources Rd, Toronto, Ontario M9P 3V6 (Canada); Wilford, Bryony [Science and Technology Branch, Environment Canada, 4905 Dufferin Street, Toronto, Ontario M3H 5T4 (Canada)

    2011-02-15

    Improving methods for assessing the spatial and temporal resolution of organic compound concentrations in marine environments is important to the sustainable management of our coastal systems. Here we evaluate the use of ethylene vinyl acetate (EVA) as a candidate polymer for thin-film passive sampling in waters of marine environments. Log K{sub EVA-W} partition coefficients correlate well (r{sup 2} = 0.87) with Log K{sub OW} values for selected pesticides and polychlorinated biphenyls (PCBs) where Log K{sub EVA-W} = 1.04 Log K{sub OW} + 0.22. EVA is a suitable polymer for passive sampling due to both its high affinity for organic compounds and its ease of coating at sub-micron film thicknesses on various substrates. Twelve-day field deployments were effective in detecting target compounds with good precision making EVA a potential multi-media fugacity meter. - Research highlights: Calibration and field testing of a thin-film passive sampler in marine systems. Ethylene vinyl acetate (EVA) is effective for a wide spectrum of organic compounds. EVA performs with high precision and reproducibility. EVA is effective in marine systems at environmentally relevant concentrations. EVA is recommended as a multi-media fugacity meter for environmental applications. - An ethylene vinyl acetate (EVA), thin-film passive sampler for the detection of organic compounds in marine environments is calibrated and field tested.

  19. Test plan for preparing the Rapid Transuranic Monitoring Laboratory for field deployment

    International Nuclear Information System (INIS)

    McIsaac, C.V.; Sill, C.W.; Gehrke, R.J.; Killian, E.W.; Watts, K.D.

    1994-04-01

    This plan describes experimental work that will be performed during fiscal year 1994 to prepare the Rapid Transuranic Monitoring Laboratory (RTML) for routine field use by US Department of Energy (DOE) Environmental Restoration and Waste Management programs. The RTML is a mobile, field-deployable laboratory developed at the Idaho National Engineering Laboratory (INEL) that provides a rapid, cost-effective means of characterizing and monitoring radioactive waste remediation sites for low-level radioactive contaminants. Analytical instruments currently installed in the RTML include an extended-range, germanium photon analysis spectrometer with an automatic sample changer; two, large-area, ionization chamber alpha spectrometers; and four alpha continuous air monitors. The RTML was field tested at the INEL during June 1993 in conjunction with the Buried Waste Integrated Demonstration's remote retrieval demonstration. The major tasks described in this test plan are to (a) evaluate the beta detectors for use in screening soil samples for 90 Sr, (b) upgrade the alpha spectral analysis software programs, and (c) upgrade the photon spectral analysis software programs

  20. Infant titi monkey behavior in the open field test and the effect of early adversity.

    Science.gov (United States)

    Larke, Rebecca H; Toubiana, Alice; Lindsay, Katrina A; Mendoza, Sally P; Bales, Karen L

    2017-09-01

    The open field test is commonly used to measure anxiety-related behavior and exploration in rodents. Here, we used it as a standardized novel environment in which to evaluate the behavioral response of infant titi monkeys (Callicebus cupreus), to determine the effect of presence of individual family members, and to assess how adverse early experience alters infant behavior. Infants were tested in the open field for 5 days at ages 4 and 6 months in four successive 5 min trials on each day. A transport cage, which was situated on one side of the open field, was either empty (non-social control) or contained the father, mother, or sibling. Infant locomotor, vocalization, and exploratory behavior were quantified. Results indicated that age, sex, social condition, and early experience all had significant effects on infant behavior. Specifically, infants were generally more exploratory at 6 months and male infants were more exploratory than females. Infants distinguished between social and non-social conditions but made few behavioral distinctions between the attachment figure and other individuals. Infants which had adverse early life experience demonstrated greater emotional and physical independence, suggesting that early adversity led to resiliency in the novel environment. © 2017 Wiley Periodicals, Inc.