WorldWideScience

Sample records for field test evaluation

  1. Report of Field Test Evaluation.

    Science.gov (United States)

    Michigan State Univ., East Lansing. Regional Instructional Materials Center for Handicapped Children and Youth.

    Reported by the Great Lakes Region Special Education Instructional Materials Center are field test evaluation of 18 auditory instructional materials for use with handicapped children who learn best through the auditory modality. Among materials evaluated are a taped program on use of the abacus and a cassette audiotape on bird habits and sounds.…

  2. Applicability of slug interference tests under Hanford Site test conditions: Analytical assessment and field test evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Spane, F.A. Jr.

    1992-04-01

    Slug interference testing may be a useful technique for characterizing the hydraulic properties of high conductivity formations where problems associated with disposal of contaminated ground water make pumping tests undesirable. The suitability of the slug interference method for characterizing the unconfined aquifer at the Hanford Site was evaluated in a two-phase investigation. The first phase consisted of an analytical assessment. Slug interference responses were predicted over the range of conditions expected for the aquifer. The effects of partial penetration, delayed-yield and aquifer anisotropy on expected test results were also evaluated and possible analytical corrections are presented. The field test evaluation was conducted at a site with two observation wells and a stress well. Results verified the analytical evaluation and gave reasonable values of hydraulic conductivity and storativity. Test design considerations that optimize the observed response are discussed.

  3. Field Test Evaluation Report on Introduction to Polymer Chemistry.

    Science.gov (United States)

    Chapman, Kenneth; Fleming, Janice

    1981-01-01

    After describing a continuing education course in polymer chemistry, summarizes materials, methods, and results of an extensive evaluation of the course. Includes a discussion of benefits for participants and a list of 14 recommendations based on the evaluation. (JN)

  4. Field Test Evaluation Report on Introduction to Polymer Chemistry.

    Science.gov (United States)

    Chapman, Kenneth; Fleming, Janice

    1981-01-01

    After describing a continuing education course in polymer chemistry, summarizes materials, methods, and results of an extensive evaluation of the course. Includes a discussion of benefits for participants and a list of 14 recommendations based on the evaluation. (JN)

  5. Fostering transfer of websearchers’ evaluation skills: a field test of two transfer theories

    NARCIS (Netherlands)

    Walraven, Amber; Brand-Gruwel, Saskia; Boshuizen, Els

    2010-01-01

    Walraven, A., Brand-Gruwel, S., & Boshuizen, H. P. A. (2010). Fostering transfer of web searchers’ evaluation skills: A field test of two transfer theories. Computers in Human Behavior, 26, 716-728.

  6. Rapid, high-temperature, field test method for evaluation of geothermal calcium carbonate scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1986-09-01

    A new test method is described that allows the rapid field testing of calcium carbonate scale inhibitors at 500/sup 0/F (260/sup 0/C). The method evolved from use of a full-flow test loop on a well with a mass flow rate of about 1 x 10/sup 6/ lbm/hr (126 kg/s). It is a simple, effective way to evaluate the effectiveness of inhibitors under field conditions. Five commercial formulations were chosen for field evaluation on the basis of nonflowing, laboratory screening tests at 500/sup 0/F (260/sup 0/C). Four of these formulations from different suppliers controlled calcium carbonate scale deposition as measured by the test method. Two of these could dislodge recently deposited scale that had not age-hardened. Performance-profile diagrams, which were measured for these four effective inhibitors, show the concentration interrelationship between brine calcium and inhibitor concentrations at which the formulations will and will not stop scale formation in the test apparatus. With these diagrams, one formulation was chosen for testing on the full-flow brine line. The composition was tested for 6 weeks and showed a dramatic decrease in the scaling occurring at the flow-control valve. This scaling was about to force a shutdown of a major, long-term flow test being done for reservoir economic evaluations. The inhibitor stopped the scaling, and the test was performed without interruption.

  7. Evaluating functional clothing in climatic chamber tests versus field tests: a comparison of quantitative and qualitative methods in product development.

    Science.gov (United States)

    Karlsson, I C; Rosenblad, E F

    1998-10-01

    For the evaluation of clothing by human beings, two different approaches can be identified--laboratory tests (i.e. climatic chamber tests) or field trials/wear trials. It has been suggested that the performance of clothing can be adequately predicted on the basis of the data obtained from climatic chamber tests and that field trials may be expendable altogether. From a product development perspective, this paper discusses the information provided by standard data collection methods and tools for the assessment of thermal comfort used in laboratory settings and compares this information with that acquired in field trials. When assessing the information provided in the laboratory test against those questions posed in a development process, the results highlight the insufficiency of objectively measurable criteria. Therefore, objective measurements alone cannot verify the adequacy of stated requirements for thermal comfort. The use of appropriate and sensitive tools for collecting subjective votes should also be noted, since small differences in thermal sensation affected the individual's preference for clothing. Exposed differences between subjects, in terms of thermophysiological as well as subjective responses, illustrate the importance of studying individual values and deviations as opposed to strict mean values for large populations in order to satisfy a potential user group. It is argued that complementary interviews form a basis for further understanding of ratings and preferences and that they should also be included in the climatic chamber evaluation 'tool box'. User satisfaction is based on a simultaneous assessment of partly opposing properties into a satisfying use value. Although laboratory test procedures can be developed and improved in relation to design issues, field evaluations must be regarded as an integrated part of an iterative development process. Only the actual use situation can provide the total spectrum of conditions on which basis

  8. Field evaluation of rapid HIV serologic tests for screening and confirming HIV-1 infection in Honduras.

    Science.gov (United States)

    Stetler, H C; Granade, T C; Nunez, C A; Meza, R; Terrell, S; Amador, L; George, J R

    1997-03-01

    To determine the ability of simple, rapid tests to identify HIV-1 antibody-positive specimens in field settings using the World Health Organization's (WHO) alternative testing strategies. Three-phase evaluation of simple, rapid assays using banked specimens and prospectively collected serum specimens at regional hospitals and rural clinics. Seven test (Retrocell, Genie, HIVCHEK, SUDS HIV-1, Testpack, Serodia HIV-1, and HIV-1/2 RTD) were evaluated and results compared with standard enzyme immunoassay (EIA) and Western blot results (phase 1). Further evaluation consisted of prospective testing of routine specimens at regional (phase 2; n = 900) and rural, peripheral laboratories (phase 3; n = 1266) throughout Honduras with selected assays. Sensitivity and specificity were calculated for each assay and combination of assays for each phase to evaluate the effectiveness of the WHO alternative testing strategies. All tests in all phases were > 99% sensitive after correcting for technical errors, with two exceptions (SUDS, phase 1; HIVCHEK, phase 3). In phase 3, where the testing algorithm was diagnostic, several combinations of assays were 100% sensitive and specific using WHO strategy II or III. For the Honduras Ministry of Health, the combination of Retrocell and Genie was found to be equally sensitive, more specific (no indeterminate results), and less expensive than EIA/Western blot. Combinations of rapid, simple HIV antibody assays provide sensitivity and specificity performance comparable to EIA/Western blot. Application of these combinations in the WHO alternative testing strategies provides an inexpensive and effective method of determining HIV status. Assay combinations using these strategies can be easily performed in small, rural laboratories and have been implemented in routine HIV screening in Honduras.

  9. Evaluation of the reliability of two field hockey specific sprint and dribble tests in young field hockey players

    NARCIS (Netherlands)

    Lemmink, K.A.; Elferink-Gemser, M.T.; Visscher, C.

    2004-01-01

    OBJECTIVES: To determine the reliability of two field hockey specific tests: the shuttle sprint and dribble test (ShuttleSDT) and the slalom sprint and dribble test (SlalomSDT). METHODS: The shuttle sprint and dribble performances of 22 young male and 12 young female field hockey players were

  10. Evaluation of the reliability of two field hockey specific sprint and dribble tests in young field hockey players

    NARCIS (Netherlands)

    Lemmink, K.A.; Elferink-Gemser, M.T.; Visscher, C.

    2004-01-01

    OBJECTIVES: To determine the reliability of two field hockey specific tests: the shuttle sprint and dribble test (ShuttleSDT) and the slalom sprint and dribble test (SlalomSDT). METHODS: The shuttle sprint and dribble performances of 22 young male and 12 young female field hockey players were assess

  11. Blind Field Test Evaluation of Raman Spectroscopy as a Forensic Tool

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, Scott D.(BATTELLE (PACIFIC NW LAB)); Vucelick, Mark E.(ASSOC WESTERN UNIVERSITY); Lee, Richard N.(BATTELLE (PACIFIC NW LAB)); Wright, Bob W.(BATTELLE (PACIFIC NW LAB))

    2001-12-01

    Analytical instrumentation for Raman spectroscopy has advanced rapidly in recent years to the point where commercial field-portable instruments are available. Raman analysis with portable instrumentation is a new capability that can provide emergency response teams with on-site evaluation of hazardous materials. Before Raman analysis is accepted and implemented in the field, realistic studies applied to unknown samples need to be performed to define the reliability of this technique. Studies described herein provide a rigorous blind field test that utilizes 2 instruments and 2 operators to analyze a matrix that consists of 58 unknown samples. Samples were searched against a custom hazardous materials reference library[Hazardous Material Response Unit (HMRU) Spectral Library Database]. Experimental design included a number of intentionally difficult situations including binary solvent mixtures and a variety of compounds that yield medium quality spectra that were not contained in the HMRU library. Results showed that over 97% of the samples were correctly identified with no occurrences of false positive identifications (compounds that were not in the library were never identified as library constituents). Statistical analysis indicated equivalent performance for both the operators and instruments. These results indicate a high level of performance that should extrapolate to actual field situations. Implementation of Raman techniques to emergency field situations should proceed with a corresponding level of confidence.

  12. Field test and evaluation of the passive neutron coincidence collar for prototype fast reactor fuel subassemblies

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, H.O.; Keddar, A.

    1982-08-01

    The passive neutron Coincidence Collar, which was developed for the verification of plutonium content in fast reactor fuel subassemblies, has been field tested using Prototype Fast Reactor fuel. For passive applications, the system measures the /sup 240/Pu-effective mass from the spontaneous fission rate, and in addition, a self-interrogation technique is used to determine the fissile content in the subassembly. Both the passive and active modes were evaluated at the Windscale Works in the United Kingdom. The results of the tests gave a standard deviation 0.75% for the passive count and 3 to 7% for the active measurement for a 1000-s counting time. The unit will be used in the future for the verification of plutonium in fresh fuel assemblies.

  13. Azimuthal cement evaluation with an acoustic phased-arc array transmitter: numerical simulations and field tests

    Science.gov (United States)

    Che, Xiao-Hua; Qiao, Wen-Xiao; Ju, Xiao-Dong; Wang, Rui-Jia

    2016-03-01

    We developed a novel cement evaluation logging tool, named the azimuthally acoustic bond tool (AABT), which uses a phased-arc array transmitter with azimuthal detection capability. We combined numerical simulations and field tests to verify the AABT tool. The numerical simulation results showed that the radiation direction of the subarray corresponding to the maximum amplitude of the first arrival matches the azimuth of the channeling when it is behind the casing. With larger channeling size in the circumferential direction, the amplitude difference of the casing wave at different azimuths becomes more evident. The test results showed that the AABT can accurately locate the casing collars and evaluate the cement bond quality with azimuthal resolution at the casing—cement interface, and can visualize the size, depth, and azimuth of channeling. In the case of good casing—cement bonding, the AABT can further evaluate the cement bond quality at the cement—formation interface with azimuthal resolution by using the amplitude map and the velocity of the formation wave.

  14. Evaluation of a companion robot based on field tests with single older adults in their homes.

    Science.gov (United States)

    Zsiga, Katalin; Tóth, András; Pilissy, Tamás; Péter, Orsolya; Dénes, Zoltán; Fazekas, Gábor

    2017-06-19

    The growing number of older adults places insurmountable load on family members and professional caregivers. Assistive technology with the aid of robots can present a possible solution. The goal of this article was to test a companion robot supporting older adults in their home environments. Eight senior volunteers were involved in the field test. They all lived alone and were self-supporting. The robot was capable of providing cognitive assistance to manage the user's daily routine. Each participant used the robot for 94.9 ± 19.6 days. The primary communication modality was voice communication in their natural language, while the touch screen display was also available for interaction with the robot. The assistance given in daily living was evaluated by subjective (the user's opinion) and objective (logged data) criteria. The most useful and the least reliable robot functions according to the users were the navigation and the verbal communication. Entertainment, locomotion, and weather forecast were the most frequently used functions, while the shopping list was the least popular. The companion robot used in the test was accepted enthusiastically by the senior subjects. Specific robot functions (mainly navigation in the apartment and the speech recognition) require improvement to better accommodate real circumstances.

  15. Field evaluation of diagnostic performance of malaria rapid diagnostic tests in western Kenya.

    Science.gov (United States)

    Wanja, Elizabeth W; Kuya, Nickline; Moranga, Collins; Hickman, Mark; Johnson, Jacob D; Moseti, Carolyne; Anova, Lalaine; Ogutu, Bernhards; Ohrt, Colin

    2016-09-07

    Malaria continues to be a major burden in the endemic regions of Kenya. Health outcomes associated with case management are dependent on the use of appropriate diagnostic methods. Rapid diagnostic tests (RDTs) have provided an important tool to help implement the WHO recommended parasite-based diagnosis in regions where expert microscopy is not available. One of the questions that must be answered when implementing RDTs is whether these tests are useful in a specific endemic region, as well as the most appropriate RDT to use. Data on the sensitivity and specificity of RDT test kits is important information to help guide test selection by national malaria control programmes. This study evaluated the diagnostic performance of RDTs including First Response (FR), CareStart (CS), SD Bioline (SD), and Binax Now (BN). The performance of these malaria kits was compared to microscopy, the gold standard, for the detection of malaria parasites. The malaria RDTs were also compared to PCR which is a more sensitive reference test. Five-hundred participants were included in the study through community screening (50 %) and testing suspected malaria cases referred from health facilities. Of the 500 participants recruited, 33 % were malaria positive by microscopy while 51.2 % were positive by PCR. Compared to microscopy, the sensitivity of eight RDTs to detect malaria parasites was 90.3-94.8 %, the specificity was 73.3-79.3 %, the positive predictive value was 62.2-68.8 %, and the negative predictive value was 94.3-96.8 %. Compared to PCR, the sensitivity of the RDTs to detect malaria parasites was 71.1-75.4 %, the specificity was 80.3-84.4 %, the positive predictive value was 80.3-83.3 %, and the negative predictive value was 73.7-76.1 %. The RDTs had a moderate measure of agreement with both microscopy (>80.1 %) and PCR (>77.6 %) with a κ > 0.6. The performance of the evaluated RDTs using field samples was moderate; hence they can significantly improve the quality

  16. Field evaluation of a prototype paper-based point-of-care fingerstick transaminase test.

    Directory of Open Access Journals (Sweden)

    Nira R Pollock

    Full Text Available Monitoring for drug-induced liver injury (DILI via serial transaminase measurements in patients on potentially hepatotoxic medications (e.g., for HIV and tuberculosis is routine in resource-rich nations, but often unavailable in resource-limited settings. Towards enabling universal access to affordable point-of-care (POC screening for DILI, we have performed the first field evaluation of a paper-based, microfluidic fingerstick test for rapid, semi-quantitative, visual measurement of blood alanine aminotransferase (ALT. Our objectives were to assess operational feasibility, inter-operator variability, lot variability, device failure rate, and accuracy, to inform device modification for further field testing. The paper-based ALT test was performed at POC on fingerstick samples from 600 outpatients receiving HIV treatment in Vietnam. Results, read independently by two clinic nurses, were compared with gold-standard automated (Roche Cobas results from venipuncture samples obtained in parallel. Two device lots were used sequentially. We demonstrated high inter-operator agreement, with 96.3% (95% C.I., 94.3-97.7% agreement in placing visual results into clinically-defined "bins" (5x upper limit of normal, >90% agreement in validity determination, and intraclass correlation coefficient of 0.89 (95% C.I., 0.87-0.91. Lot variability was observed in % invalids due to hemolysis (21.1% for Lot 1, 1.6% for Lot 2 and correlated with lots of incorporated plasma separation membranes. Invalid rates <1% were observed for all other device controls. Overall bin placement accuracy for the two readers was 84% (84.3%/83.6%. Our findings of extremely high inter-operator agreement for visual reading-obtained in a target clinical environment, as performed by local practitioners-indicate that the device operation and reading process is feasible and reproducible. Bin placement accuracy and lot-to-lot variability data identified specific targets for device optimization and

  17. Rapid high temperature field test method for evaluation of geothermal calcite scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1982-08-01

    A test method is described which allows the rapid field testing of calcite scale inhibitors in high- temperature geothermal brines. Five commercial formulations, chosen on the basis of laboratory screening tests, were tested in brines with low total dissolved solids at ca 500 F. Four were found to be effective; of these, 2 were found to be capable of removing recently deposited scale. One chemical was tested in the full-flow brine line for 6 wks. It was shown to stop a severe surface scaling problem at the well's control valve, thus proving the viability of the rapid test method. (12 refs.)

  18. Architectural design and first results evaluation of the PowerMatching City field test

    Energy Technology Data Exchange (ETDEWEB)

    Kamphuis, I.G.; Roossien, B. [Unit Efficiency and Infrastructure, Energy research Centre of the Netherlands, Westerduinweg 3, P.O. Box 1, 1755 ZG Petten (Netherlands); Bliek, F.W.; Van den Noort, A. [KEMA/Gas Consultancy Services, Groningen (Netherlands); Van de Velde, J.; De Wit, J. [HUMIQ, Groningen (Netherlands)

    2011-01-15

    Starting from the beginning of 2010, in the EU FP6 Integral4 project, a large-scale SmartGrid field test with active participation of end-user installation nodes in the electricity network is running. A high-bandwidth dedicated ICTnetwork has been rolled-out to connect electricity supply and demand nodes and to collect data. In the test, the software agent based PowerMatcher technology is applied in a Virtual Power Plant (VPP) setting to satisfy a number of commercial and grid related optimization objectives. The VPP in the test consists of 25 heating devices in homes in Hoogkerk, nodes with PV and wind generated electricity, residential and mobile (full EV's) electricity storage nodes and intelligent home appliances. Primary process flexibility for the heating system's hybrid heat pumps and micro-CHP is enlarged by using hot water filled heat buffers. Additional gas burning heating capacity to be used in peak periods was added to the system configuration. Additional demand response flexibility is achieved by optimizing the charging strategy of the nodes with electricity storage and the operation of devices connected to demands like refrigerators and washing machines. In this way, on a real-time basis, the VPP has been shown to be usable for optimization to satisfy objectives for compensation of the variable output of renewables, for improving grid operation and functions for commercial operation. In this paper the architectural design and the application of the PowerMatcher approach is evaluated. The first results of operating the use cases are also presented.

  19. Field Test Evaluation of Effect on Cone Resistance Caused by Change in Penetration Rate

    DEFF Research Database (Denmark)

    Poulsen, Rikke; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    2012-01-01

    in Dronninglund where the subsoil primary consists of sandy silt. A total of 15 cone penetration tests with penetration rates varying from 60 to 0.5 mm/s and two geotechnical borings were conducted at the test site. Large soil samples were also collected from the test site in order to determine soil properties......This paper presents how a change in cone penetration rate affects the measured cone resistance during cone penetration testing in silty soils. Regardless of soil, type the standard rate of penetration is 20 mm/s and it is generally accepted that undrained penetration occurs in clay while drained...... penetration occurs in sand. In intermediate soils such as silty soils, the standard cone penetration rate may result in drainage conditions varying from undrained to partially or fully drained conditions. Field cone penetrations tests have been conducted with different penetration rates on a test site...

  20. Laboratory and Modeling Evaluations in Support of Field Testing for Desiccation at the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    Truex, Michael J.; Oostrom, Martinus; Freedman, Vicky L.; Strickland, Christopher E.; Wietsma, Thomas W.; Tartakovsky, Guzel D.; Ward, Anderson L.

    2011-02-23

    The Deep Vadose Zone Treatability Test Plan for the Hanford Central Plateau includes testing of the desiccation technology as a potential technology to be used in conjunction with surface infiltration control to limit the flux of technetium and other contaminants in the vadose zone to the groundwater. Laboratory and modeling efforts were conducted to investigate technical uncertainties related to the desiccation process and its impact on contaminant transport. This information is intended to support planning, operation, and interpretation of a field test for desiccation in the Hanford Central Plateau.

  1. Processing equipment for resource recovery systems. Volume 3: Field test evaluation of shredders

    Science.gov (United States)

    Savage, G. M.; Shiflett, G. R.

    1980-07-01

    A program to test and evaluate large scale shredders used for the size reduction of solid waste is reported. Tests were conducted on seven horizontal hammermills, one vertical hammermill, and one vertical ring shredder at six commercial sites. Both two stage size reduction and single stage size reduction were studied. Analytical relationships among the comminution parameters and the establishment of levels of performance for energy consumption and hammer wear associated with size reduction of solid waste are developed.

  2. Evaluation of initial collector field performance at the Langley Solar Building Test Facility

    Science.gov (United States)

    Boyle, R. J.; Knoll, R. H.; Jensen, R. N.

    1977-01-01

    The thermal performance of the solar collector field for the NASA Langley Solar Building Test Facility is given for October 1976 through January 1977. An 1180 square meter solar collector field with seven collector designs helped to provide hot water for the building heating system and absorption air conditioner. The collectors were arranged in 12 rows with nominally 51 collectors per row. Heat transfer rates for each row are calculated and recorded along with sensor, insolation, and weather data every 5 minutes using a mini-computer. The agreement between the experimental and predicted collector efficiencies was generally within five percentage points.

  3. Field Test and Evaluation of Engineered Biomineralization Technology for Sealing Existing Wells

    Energy Technology Data Exchange (ETDEWEB)

    Cunningham, Alfred [Montana State Univ., Bozeman, MT (United States)

    2015-12-21

    This research project addresses one of the goals of the U.S. Department of Energy (DOE) Carbon Storage Program (CSP) aimed at developing Advanced Wellbore Integrity Technologies to Ensure Permanent Geologic Carbon Storage. The technology field-tested in this research project is referred to as microbially induced calcite precipitation (MICP), which utilizes a biologically-based process to precipitate calcium carbonate. If properly controlled MICP can successfully seal fractures, high permeability zones, and compromised wellbore cement in the vicinity of wellbores and in nearby caprock, thereby improving the storage security of geologically-stored carbon dioxide. This report describes an MICP sealing field test performed on a 24.4 cm (9.625 inch) diameter well located on the Gorgas Steam Generation facility near Jasper, Alabama. The research was aimed at (1) developing methods for delivering MICP promoting fluids downhole using conventional oil field technologies and (2) assessing the ability of MICP to seal cement and formation fractures in the near wellbore region in a sandstone formation. Both objectives were accomplished successfully during a field test performed during the period April 1-11, 2014. The test resulted in complete biomineralization sealing of a horizontal fracture located 340.7 m (1118 feet) below ground surface. A total of 24 calcium injections and six microbial inoculation injections were required over a three day period in order to achieve complete sealing. The fractured region was considered completely sealed when it was no longer possible to inject fluids into the formation without exceeding the initial formation fracture pressure. The test was accomplished using conventional oil field technology including an 11.4 L (3.0 gallon) wireline dump bailer for injecting the biomineralization materials downhole. Metrics indicating successful MICP sealing included reduced injectivity during seal formation, reduction in pressure falloff, and

  4. Evaluation of the field tests of flexibility of the lower extremity: reliability and the concurrent and factorial validity.

    Science.gov (United States)

    Bozic, Predrag R; Pazin, Nemanja R; Berjan, Bobana B; Planic, Nenad M; Cuk, Ivan D

    2010-09-01

    The purpose of this study was to evaluate the standard field tests of flexibility of the lower extremity through their (a) intratrial and test-retest reliability, (b) concurrent validity with respect to a high-precision 3D system for kinematic recording, and (c) factorial validity. Physically active men (n = 84) were tested over 2 separate sessions by means of standard simple devices (kinanthropometry, ruler, and protractor) on the following flexibility tests: leg raise in a supine position, hip abduction test, single-legged knee bend (SLKB), sideward leg splits (SdLS), sit and reach (SR), sideways leg splits, and lengthwise leg splits. Additionally, 17 participants were simultaneously tested by means of a laboratory 3D kinematic analysis system. Most of the tests demonstrated high intratrial and test-retest reliability and concurrent validity. The exceptions were SLKB and SR tests that revealed not only a somewhat lower reliability but also a lower concurrent validity. For estimation of factorial validity, we applied a principal component analysis of the intercorrelations among the evaluated flexibility tests that revealed a single extracted principal component. Strong mutual relationships among them also suggest that very few of them, if not a single one, should be applied within the standard batteries of physical performance tests. We particularly recommend using SdLS over the most frequently used SR not only because of its relatively high reliability and validity but also because of its postural properties. Finally, we conclude that most of the standard field tests of flexibility of the lower extremity based on using inexpensive field equipment could be both reliable and valid and, therefore, justified for use in routine testing.

  5. Field evaluation of a horizontal well recirculation system for groundwater treatment: Pilot test at the Clean Test Site Portsmouth Gaseous Diffusion Plant, Piketon, Ohio

    Energy Technology Data Exchange (ETDEWEB)

    Muck, M.T.; Kearl, P.M.; Siegrist, R.L. [and others

    1998-08-01

    This report presents the results of field testing a horizontal well recirculation system at the Portsmouth Gaseous Diffusion Plant (PORTS). The recirculation system uses a pair of horizontal wells, one for groundwater extraction and treatment and the other for reinjection of treated groundwater, to set up a recirculation flow field. The induced flow field from the injection well to the extraction well establishes a sweeping action for the removal and treatment of groundwater contaminants. The overall purpose of this project is to study treatment of mixed groundwater contaminants that occur in a thin water-bearing zone not easily targeted by traditional vertical wells. The project involves several research elements, including treatment-process evaluation, hydrodynamic flow and transport modeling, pilot testing at an uncontaminated site, and pilot testing at a contaminated site. The results of the pilot test at an uncontaminated site, the Clean Test Site (CTS), are presented in this report.

  6. Evaluation of cardiorespiratory fitness using three field tests in obese adolescents: validity, sensitivity and prediction of peak VO2.

    Science.gov (United States)

    Quinart, Sylvain; Mougin, Fabienne; Simon-Rigaud, Marie-Laure; Nicolet-Guénat, Marie; Nègre, Véronique; Regnard, Jacques

    2014-09-01

    Evaluation of cardiorespiratory fitness in obese adolescents is necessary to develop personalised retraining programmes. We aimed to measure cardiorespiratory fitness using 3 field tests, and to evaluate their validity and sensitivity compared to values obtained by laboratory tests. Longitudinal interventional study in obese adolescents admitted to a rehabilitation centre for a 9-month programme of obesity management. A 12-min walk/run test, an adapted 20 m shuttle walk-run test (starting speed 4 km h(-1), increments of 0.5 km h(-1)min(-1)) and a 4-level submaximal cycle ergometer test were performed to estimate respectively distance covered in 12 min, maximum speed and maximal aerobic power. Thirty adolescents aged 14.2 ± 1.6 years were included. After 9 months intervention, we observed a significant reduction in body mass index, and an increase in peak VO2 and field test results. We observed significant correlations between pre- and post-intervention values of peak VO2 and distance covered in 12 min (r=0.70 pre; r=0.82 post), maximum speed (r=0.80 pre; r=0.83 post) and maximal aerobic power (r=0.71 pre; r=0.84 post). Multiple linear regression made it possible to estimate peak VO2 based on results from the 3 field tests using prediction equations specific to a population of obese adolescents. These field tests, including the adapted 20 m shuttle walk-run test, adequately assess cardiorespiratory fitness in obese adolescents, and are sensitive to changes over time. Predictive equations including BMI are useful in clinical practice to predict peak VO2 in these patients. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  7. Field evaluation of a rapid diagnostic test to detect antibodies in human toxocariasis.

    Science.gov (United States)

    Lim, P K C; Yamasaki, H; Mak, J W; Wong, S F; Chong, C W; Yap, I K S; Ambu, S; Kumarasamy, V

    2015-08-01

    Human toxocariasis which is caused mainly by the larvae of Toxocara canis and Toxocara cati, is a worldwide zoonotic disease that can be a potentially serious human infection. The enzyme-linked immunosorbent assay (ELISA) using T. canis excretory-secretory (TES) antigens harvested from T. canis larvae is currently the serological test for confirming toxocariasis. An alternative to producing large amounts of Toxocara TES and improved diagnosis for toxocariasis is through the development of highly specific recombinant antigens such as the T. canis second stage larva excretory-secretory 30 kDa protein (recTES-30). The aim of this study was to evaluate the sensitivity and specificity of a rapid diagnostic kit (RDT, named as iToxocara kit) in comparison to recTES-30 ELISA in Serendah Orang Asli village in Selangor, Malaysia. A total of 133 subjects were included in the study. The overall prevalence rates by ELISA and RDT were 29.3% and 33.1%, respectively, with more positive cases detected in males than females. However, no association was found between toxocariasis and gender or age. The percentage sensitivity, specificity, positive predictive value and negative predictive value of RDT were 85.7%, 90.1%, 80% and 93.2%, respectively. The prevalence for toxocariasis in this population using both ELISA and RDT was 27.1% (36/133) and the K-concordance test suggested good agreement of the two tests with a Cohen's kappa of 0.722, Ptoxocariasis.

  8. Field Evaluation of Alternative Testing Strategies for the Detection of HIV Infection in Beijing

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Objective To identify a cost-efficient alternative antibody testing strategy for screening and confirmation of HIV infection by rapid simple tests (RSTs) and enzyme-linked immunosorbent assays (ELISAs). Methods Four RSTs (RST1,RST2, RST3, and RST4 ) and five ELISAs (ELISA1, ELISA2, ELISA3, ELISA4, and ELISA5) were evaluated in two phases by using banked and serum specimens prospectively collected at regional hospitals and voluntary counseling and testing (VCT)centers in Beijing. A total of 200 banked serum specimens were included in the first phase, including 62 HIV-positive, 127 HIV-negative and 11 indeterminate specimens. All specimens were tested by four RSTs and five ELISAs respectively. The second phase involved prospective testing of 389 routine specimens, including 92 HIV-positive, 287 HIV-negative, and 10 indeterminate specimens. All the specimens were tested by two RSTs (RST2 and RST4) and three ELISAs (ELISA1, ELISA3,and ELISA4), which were selected for their respective excellent sensitivity and/or specificity. Western blot (WB) was used as a gold standard for confirming the reactivity of all the specimens. Results Sensitivity, specificity, and efficacy were calculated for each assay in two phases. In the first phase, four assays (ELISA4, RST2, RST3, and RST4) had a specificity of 100%. For the determination of efficacy, ELISA4, RST2, and RST4 were selected in the second phase. ELISA1 and ELISA3 which have a sensitivity of 95.9% and 93.2% respectively also entered this phase. In the second phase, all the five assays (ELISA1, ELISA3, ELISA4, RST2, and RST4) had a sensitivity and specifity of over 90%. ELISA1 had a sensitivity of 99% and ELISA4 a specificity of 99%. Conclusion The sensitivity ELISA1 and the specificit of ELISA4 are comparable to ELISA/WB standard strategy. Application of this alternative testing strategy provides a cost-effective method for determining HIV prevalence in Beijing.

  9. Field Validation of Toxicity Tests to Evaluate the Potential for Beneficial Use of Produced Water

    Energy Technology Data Exchange (ETDEWEB)

    Joseph Bidwell; Jonathan Fisher; Naomi Cooper

    2008-03-31

    This study investigated potential biological effects of produced water contamination derived from occasional surface overflow and possible subsurface intrusion at an oil production site along the shore of Skiatook Lake, Oklahoma. We monitored basic chemistry and acute toxicity to a suite of standard aquatic test species (fathead minnow-Pimephales promelas, Daphnia pulex, Daphnia magna, and Ceriodaphnia dubia) in produced water and in samples taken from shallow groundwater wells on the site. Toxicity identification evaluations and ion toxicity modeling were used to identify toxic constituents in the samples. Lake sediment at the oil production site and at a reference site were also analyzed for brine intrusion chemically and by testing sediment toxicity using the benthic invertebrates, Chironomus dilutus, and Hyallela azteca. Sediment quality was also assessed with in situ survival and growth studies with H. azteca and the Asian clam, Corbicula fluminea, and by benthic macroinvertebrate community sampling. The produced water was acutely toxic to the aquatic test organisms at concentrations ranging from 1% to 10% of the whole produced water sample. Toxicity identification evaluation and ion toxicity modeling indicated major ion salts and hydrocarbons were the primary mixture toxicants. The standardized test species used in the laboratory bioassays exhibited differences in sensitivity to these two general classes of contaminants, which underscores the importance of using multiple species when evaluating produced water toxicity. Toxicity of groundwater was greater in samples from wells near a produced water injection well and an evaporation pond. Principle component analyses (PCA) of chemical data derived from the groundwater wells indicated dilution by lake water and possible biogeochemical reactions as factors that ameliorated groundwater toxicity. Elevated concentrations of major ions were found in pore water from lake sediments, but toxicity from these ions was

  10. Field evaluation of rapid diagnostic tests for malaria in Yaounde, Cameroon.

    Science.gov (United States)

    Tahar, Rachida; Sayang, Collins; Ngane Foumane, Vincent; Soula, Georges; Moyou-Somo, Roger; Delmont, Jean; Basco, Leonardo K

    2013-02-01

    Rapid diagnostic tests (RDTs) are affordable, alternative diagnostic tools. The present study aimed to evaluate RDTs available in Cameroon and compare their characteristics to follow the parasitological response of patients for 28 days. Malaria diagnosis was assessed in 179 febrile patients using conventional microscopy as the reference method. Parascreen detects both Plasmodium falciparum-specific histidine-rich protein 2 (Pf HRP-2) and Pan-specific plasmodial lactate dehydrogenase (pLDH) in all four human Plasmodium spp. Diaspot is based on the detection of Pf HRP-2. OptiMAL-IT (pLDH specific for P. falciparum and pLDH for all four human Plasmodium spp.) was assessed for comparison. The reliability of RDTs was evaluated by calculating the sensitivity, specificity, positive predictive value, negative predictive value, false-positive rate, false-negative rate, and likelihood ratio. The clinical outcome of 18 children treated with atovaquone-proguanil and followed for 28 days was evaluated using microscopy and RDTs. Of 179 samples, 133 (74.3%) were pure P. falciparum-positive smears, 4 (2.2%) pure P. malariae-positive smears, and 42 (23.5%) negative smears. Parascreen and Diaspot had high sensitivity (>92%) and positive predictive values (>94%). The specificities for Parascreen and Diaspot were 81.0% and 90.5%, respectively. The false-positive rates and the false-negative rates were 19.0% and 4.5% for Parascreen and 9.5% and 8.3% for Diaspot, respectively. Most false-negatives occurred in samples with low parasitaemia (500 asexual parasites/μL). Four pure P. malariae were only detected by the pan-Plasmodium bands of Parascreen and OptiMAL-IT. In blood samples from patients treated and followed-up for 28 days, HRP2-based RDTs remained positive in most samples until Day 28. Despite negative smears, OptiMAL-IT remained positive in several patients until Day 7 but was negative in all patients from Day 14 onwards. RDTs can improve the management of febrile patients. The

  11. Field evaluation of a rapid diagnostic test (Parascreen™ for malaria diagnosis in the Peruvian Amazon

    Directory of Open Access Journals (Sweden)

    Rodriguez Hugo

    2010-06-01

    Full Text Available Abstract Background The rapid diagnostic tests for malaria (RDT constitute a fast and opportune alternative for non-complicated malaria diagnosis in areas where microscopy is not available. The objective of this study was to validate a RDT named Parascreen™ under field conditions in Iquitos, department of Loreto, Peru. Parascreen™ is a RDT that detects the histidine-rich protein 2 (HRP2 antigen from Plasmodium falciparum and lactate deshydrogenase from all Plasmodium species. Methods Parascreen™ was compared with microscopy performed by experts (EM and polymerase chain reaction (PCR using the following indicators: sensitivity (Se, specificity (Sp, positive (PV+ and negative predictive values (PV-, positive (LR+ and negative likehood ratio (LR-. Results 332 patients with suspected non-complicated malaria who attended to the MOH health centres were enrolled between October and December 2006. For P. falciparum malaria, Parascreen™ in comparison with EM, had Se: 53.5%, Sp: 98.7%, PV+: 66.7%, PV-: 97.8%, LR+: 42.27 and LR-: 0.47; and for non-P. falciparum malaria, Se: 77.1%, Sp: 97.6%, PV+: 91.4%, PV-: 92.7%, LR+: 32.0 and LR-: 0.22. The comparison of Parascreen™ with PCR showed, for P. falciparum malaria, Se: 81.8%, Sp: 99.1%, PV+: 75%, PV-: 99.4, LR+: 87.27 and LR-: 0.18; and for non-P. falciparum malaria Se: 76.1%, Sp: 99.2%, PV+: 97.1%, PV-: 92.0%, LR+: 92.51 and LR-: 0.24. Conclusions The study results indicate that Parascreen™ is not a valid and acceptable test for malaria diagnosis under the field conditions found in the Peruvian Amazon. The relative proportion of Plasmodium species, in addition to the genetic characteristics of the parasites in the area, must be considered before applying any RDT, especially after the finding of P. falciparum malaria parasites lacking pfhrp2 gene in this region.

  12. Narrative-based educational nursing intervention for managing hospitalized older adults at risk for delirium: field testing and qualitative evaluation.

    Science.gov (United States)

    Bélanger, Louise; Ducharme, Francine

    2015-01-01

    Though delirium is a common complication among hospitalized older adults and the nursing care required in these situations is complex, the subject has received little attention in the literature on continuing nursing education. A study was undertaken to field test and qualitatively evaluate a narrative-based educational intervention for nurses in hospital units with a high incidence of delirium. Triangulated data collection allowed carrying out a qualitative evaluation of the intervention process and outcomes. Process evaluation showed that the intervention was facilitated by the participants' attitudes and diversity of experience, as well as by the use of real care situations, which allowed integrating theory and practice. Outcome evaluation brought to light numerous elements of empirical, ethical and esthetic knowledge expressed by the participants. Study results evidence the applicability of such interventions as part of continuing nursing education and their contribution to knowledge development.

  13. Evaluation of Measurement Uncertainty of Radiated EMC Tests in Arbitrary Field Generators using Surface Currents on DUT

    Directory of Open Access Journals (Sweden)

    T. Schrader

    2005-01-01

    Full Text Available We present a method for the evaluation of measurement uncertainty in radiated EMC tests. It is based on the measurement of surface current densities on a sphere, the results are compared to the surface current distribution on a sphere in a free-space environment obtained by numerical calculations. The free-space is considered to be a reference field generator. By this method we avoid burdening any systematic deviations of one particular (historic method to any of the others. We evaluate the ratio J/E of the measured surface current density J and the measured empty electrical field strength E for both the reverberation chamber and the semi-anechoic chamber.

  14. Field Test Analysis and Reliability of the Fieldwork Evaluation for the Occupational Therapist.

    Science.gov (United States)

    Cooper, Richard G.; Crist, Patricia A. Hickerson

    1988-01-01

    The Fieldwork Evaluation was designed to measure the performance judgment and attitude of occupational therapy students on tasks related to the profession. This article discusses the history and reliability of the Fieldwork Evaluation. (JOW)

  15. Field Test Evaluation of Conservation Retrofits of Low-Income, Single-Family Buildings in Wisconsin: Blower-Door-Directed Infiltration Reduction Procedure, Field Test Implementation and Results

    Energy Technology Data Exchange (ETDEWEB)

    Gettings, M.B.

    2001-05-21

    A blower-door-directed infiltration retrofit procedure was field tested on 18 homes in south central Wisconsin. The procedure, developed by the Wisconsin Energy Conservation Corporation, includes recommended retrofit techniques as well as criteria for estimating the amount of cost-effective work to be performed on a house. A recommended expenditure level and target air leakage reduction, in air changes per hour at 50 Pascal (ACH50), are determined from the initial leakage rate measured. The procedure produced an average 16% reduction in air leakage rate. For the 7 houses recommended for retrofit, 89% of the targeted reductions were accomplished with 76% of the recommended expenditures. The average cost of retrofits per house was reduced by a factor of four compared with previous programs. The average payback period for recommended retrofits was 4.4 years, based on predicted energy savings computed from achieved air leakage reductions. Although exceptions occurred, the procedure's 8 ACH50 minimum initial leakage rate for advising retrofits to be performed appeared a good choice, based on cost-effective air leakage reduction. Houses with initial rates of 7 ACH50 or below consistently required substantially higher costs to achieve significant air leakage reductions. No statistically significant average annual energy savings was detected as a result of the infiltration retrofits. Average measured savings were -27 therm per year, indicating an increase in energy use, with a 90% confidence interval of 36 therm. Measured savings for individual houses varied widely in both positive and negative directions, indicating that factors not considered affected the results. Large individual confidence intervals indicate a need to increase the accuracy of such measurements as well as understand the factors which may cause such disparity. Recommendations for the procedure include more extensive training of retrofit crews, checks for minimum air exchange rates to insure air

  16. Field Evaluations Test Plan for Validation of Alternative Low-Emission Surface Preparation/Depainting Technologies for Structural Steel

    Science.gov (United States)

    Lewis, Pattie

    2005-01-01

    and approve alternative surface preparation technologies for use at NASA and AFSPC installations. Materials and processes will be evaluated with the goal of selecting those processes that will improve corrosion protection at critical systems, facilitate easier maintenance activity, extend maintenance cycles, eliminate flight hardware contamination and reduce the amount of hazardous waste generated. This Field Evaluations Test Plan defines the field evaluation and testing requirements for validating alternative surface preparation/depainting technologies and supplements the JTP. The field evaluations will be performed at Stennis Space Center, Mississippi, under the oversight of the Project Engineer. Additional field evaluations may be performed at other NASA centers or AFSPC facilities.

  17. Evaluation of a 3% surf solution (surf field mastitis test) for the diagnosis of subclinical bovine and bubaline mastitis.

    Science.gov (United States)

    Muhammad, Ghulam; Naureen, Abeera; Asi, Muhammad Nadeem; Saqib, Muhammad; Fazal-ur-Rehman

    2010-03-01

    To evaluate a 3% solution of household detergent viz., Surf Excel (Surf field mastitis test, SFMT) vis-à-vis California mastitis test (CMT), Whiteside test (WST), somatic cell counts (SCC; cut off limit = 5 x 10(5) cells per millilitre) and bacteriological cultures for the detection of subclinical mastitis in quarter foremilk samples (n=800) of dairy cows and buffaloes. Culture and SCC were used as gold standards. All tests were evaluated parallel and serial patterns. The sensitivities of SFMT, SCC, culture, CMT and WST in parallel testing were 72.82, 81.55, 87.38, 75.73 and 54.37%, respectively in cows, while 66.22, 79.73, 82.43, 70.27 and 50.00, respectively in buffaloes. SFMT was significantly (pCMT in both species. In serial testing, percent specificity of SFMT (87.12 in cow; 85.16 in buffaloes) was significantly (PCMT (83.33 in cow; 80.64 in buffaloes). The negative predictive values of SFMT (93.50 in cow; 96.35 in buffaloes) differed non-significantly from that of CMT (94.02 in cow; 96.15 in buffaloes). The kappa index between the tests was moderate to perfect both in parallel (0.54 to >0.80) and serial (0.58 to >0.8) testing. On the basis of closely similar diagnostic efficiency of SFMT to CMT in terms of sensitivity, specificity, predictive values and kappa index together with inexpensive and ready availability of SFMT reagent, it tempting to suggest that SFMT can be use as a cheaper, user-friendly alternative animal-side subclinical mastitis diagnostic test in poor countries.

  18. Evaluating the suitability of Hydrobia ulvae as a test species for sediment metal toxicity testing applying a tissue residue approach to metal mixtures in laboratory and field exposures.

    Science.gov (United States)

    Campana, Olivia; Rodríguez, Antonio; Blasco, Julián

    2013-05-01

    A major weakness in evaluating the suitability of a biomonitor organism is the poor ability to predict the variability of the bioavailability of metals from measured environmental concentrations. In this study, the intertidal gastropod Hydrobia ulvae was used to evaluate its suitability as a test organism for assessing sediment metal toxicity. Toxicity tests were run with sediments spiked with copper, cadmium and zinc applied both as single metal and as a mixture to investigate toxicological interactions evaluating different lethal and sublethal effects. Dose-response relationships were constructed based both on tissue residue approach and particulate metal concentrations. Because metal-spiked sediments used in routine toxicity tests often do not exhibit the same adsorption/desorption kinetics as the natural sediments, the laboratory results were compared to 10-d bioassays conducted with natural field sediments collected from the Guadalete estuary (SW Spain). Highly significant correlations between tissue residue concentrations and particulate metal concentrations were found for all metal-spiked or field-collected and demonstrated that: (i) H. ulvae readily accumulated copper and cadmium in response to contamination and (ii) dietary uptake was determined to be the most significant route of metal exposure. The comparison of the modeled tissue residue-response curve developed from the mixture tests was in good agreement with the results from the bioassay conducted with field sediments and strongly demonstrated that H. ulvae is also a suitable test organism for assessing copper sediment toxicity. In contrast, the dose-response curve expressed as a function of total particulate metal concentrations would fail in predicting effect, erroneously assessing higher metal toxicity.

  19. Evaluation of Test Strips for Determining Inorganic Contaminants in Field Water

    Science.gov (United States)

    1993-02-26

    1.273 g SAE fine test spark plug dust, 15.08 g sea salts, and 103 mg humic acid were mixed with 1L water. Powdered phosphate buffer consisted of an...intimate mixture of 1.36 g potassium dihydrogen phosphate (KH 2PO 4) and 1.42 g sodium monohydrogen phosphate (G a2HPO4 ). Instrumentation...by the test kit. A powdered phosphate buffer was prepared and a protocol developed for its use to adjust the pH of the cyanide samples to one within

  20. Fostering transfer of web searchers' evaluation skills: A field test of two transfer theories

    NARCIS (Netherlands)

    Walraven, Amber; Brand-Gruwel, Saskia; Boshuizen, Henny P.A.

    2010-01-01

    Transfer of complex cognitive skills is important when stimulating students to become life long learners. An example of a complex cognitive skill is the skill of evaluating results, information and source while solving information problems using the WWW. Especially the knowledge and use of

  1. The Collegial Evaluation Program: A Manual for the Professional Development of Teachers. Field Test Edition.

    Science.gov (United States)

    Dornbusch, Stanford M.; And Others

    The Collegial Evaluation Program leads to improved teaching by systematizing a way for teachers to obtain frequent, focused feedback from themselves, their students, and their colleagues. The process can be used by a single pair of teachers, a teaching team, a department, or an entire faculty. The purpose of this manual is to introduce the idea of…

  2. Fostering transfer of websearchers’ evaluation skills: A field test of two transfer theories

    NARCIS (Netherlands)

    Walraven, Amber; Brand-Gruwel, Saskia; Boshuizen, Henny P.A.

    2010-01-01

    Transfer of complex cognitive skills is important when stimulating students to become life long learners. An example of a complex cognitive skill is the skill of evaluating results, information and source while solving information problems using the WWW. Especially the knowledge and use of evaluatio

  3. Flood-Fighting Structures Demonstration and Evaluation Program: Laboratory and Field Testing in Vicksburg, Mississippi

    Science.gov (United States)

    2007-07-01

    actual flood conditions. Log impact tests were conducted at a water elevation of 66 percent levee height to model the impact of waterborne debris...sand. A total of 250 cu yd of sand was delivered to the site. An automatic-speed sandbagger, Model ASB-3 (Hogan Manufacturing, Inc.) was rented...Local Sponsor Mr. Renold Minsky , President, Fifth Louisiana Levee Board Mr. Bump Calloway, Director, Warren County (MS) Civil Defense The

  4. Field Test Evaluation of Effect on Cone Resistance Caused by Change in Penetration Rate

    DEFF Research Database (Denmark)

    Poulsen, Rikke; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    2012-01-01

    This paper presents how a change in cone penetration rate affects the measured cone resistance during cone penetration testing in silty soils. Regardless of soil, type the standard rate of penetration is 20 mm/s and it is generally accepted that undrained penetration occurs in clay while drained...... in the laboratory. A change in the measured cone resistance occurs by lowering the penetration rate. This is caused by the changes in drainage conditions. Compared to the normal penetration rate of 20 mm/s, this paper illustrates that lowering the penetration rate leads to an increase in the cone resistance from 1...

  5. SEURAT: Safety Evaluation Ultimately Replacing Animal Testing--recommendations for future research in the field of predictive toxicology.

    Science.gov (United States)

    Daston, George; Knight, Derek J; Schwarz, Michael; Gocht, Tilman; Thomas, Russell S; Mahony, Catherine; Whelan, Maurice

    2015-01-01

    The development of non-animal methodology to evaluate the potential for a chemical to cause systemic toxicity is one of the grand challenges of modern science. The European research programme SEURAT is active in this field and will conclude its first phase, SEURAT-1, in December 2015. Drawing on the experience gained in SEURAT-1 and appreciating international advancement in both basic and regulatory science, we reflect here on how SEURAT should evolve and propose that further research and development should be directed along two complementary and interconnecting work streams. The first work stream would focus on developing new 'paradigm' approaches for regulatory science. The goal here is the identification of 'critical biological targets' relevant for toxicity and to test their suitability to be used as anchors for predicting toxicity. The second work stream would focus on integration and application of new approach methods for hazard (and risk) assessment within the current regulatory 'paradigm', aiming for acceptance of animal-free testing strategies by regulatory authorities (i.e. translating scientific achievements into regulation). Components for both work streams are discussed and may provide a structure for a future research programme in the field of predictive toxicology.

  6. Unmanned airborne vehicle (UAV): Flight testing and evaluation of two-channel E-field very low frequency (VLF) instrument

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    Using VLF frequencies, transmitted by the Navy`s network, for airborne remote sensing of the earth`s electrical, magnetic characteristics was first considered by the United States Geological Survey (USGS) around the mid 1970s. The first VLF system was designed and developed by the USGS for installation and operation on a single engine, fixed wing aircraft used by the Branch of Geophysics for geophysical surveying. The system consisted of five channels. Two E-field channels with sensors consisting of a fixed vertical loaded dipole antenna with pre-amp mounted on top of the fuselage and a gyro stabilized horizontal loaded dipole antenna with pre-amp mounted on a tail boom. The three channel magnetic sensor consisted of three orthogonal coils mounted on the same gyro stabilized platform as the horizontal E-field antenna. The main features of the VLF receiver were: narrow band-width frequency selection using crystal filters, phase shifters for zeroing out system phase variances, phase-lock loops for generating real and quadrature gates, and synchronous detectors for generating real and quadrature outputs. In the mid 1990s the Branch of Geophysics designed and developed a two-channel E-field ground portable VLF system. The system was built using state-of-the-art circuit components and new concepts in circuit architecture. Small size, light weight, low power, durability, and reliability were key considerations in the design of the instrument. The primary purpose of the instrument was for collecting VLF data during ground surveys over small grid areas. Later the system was modified for installation on a Unmanned Airborne Vehicle (UAV). A series of three field trips were made to Easton, Maryland for testing and evaluating the system performance.

  7. Field Evaluation of a High Throughput Loop Mediated Isothermal Amplification Test for the Detection of Asymptomatic Plasmodium Infections in Zanzibar

    OpenAIRE

    Aydin-Schmidt, Berit; Morris, Ulrika; Ding, Xavier C; Jovel, Irina; Mwinyi I Msellem; Bergman, Daniel; Islam, Atiqul; Ali, Abdullah S; Polley, Spencer; Gonzalez, Iveth J.; Mårtensson, Andreas; Björkman, Anders

    2017-01-01

    Background New field applicable diagnostic tools are needed for highly sensitive detection of residual malaria infections in pre-elimination settings. Field performance of a high throughput DNA extraction system for loop mediated isothermal amplification (HTP-LAMP) was therefore evaluated for detecting malaria parasites among asymptomatic individuals in Zanzibar. Methods HTP-LAMP performance was evaluated against real-time PCR on 3008 paired blood samples collected on filter papers in a commu...

  8. Field Evaluation of a High Throughput Loop Mediated Isothermal Amplification Test for the Detection of Asymptomatic Plasmodium Infections in Zanzibar

    OpenAIRE

    Aydin-Schmidt, Berit; Morris, Ulrika; Ding, Xavier C; Jovel, Irina; Msellem, Mwinyi I; Bergman, Daniel; Islam, Atiqul; Ali, Abdullah S.; Polley, Spencer; Gonzalez, Iveth J.; Mårtensson, Andreas; Björkman, Anders

    2017-01-01

    Background New field applicable diagnostic tools are needed for highly sensitive detection of residual malaria infections in pre-elimination settings. Field performance of a high throughput DNA extraction system for loop mediated isothermal amplification (HTP-LAMP) was therefore evaluated for detecting malaria parasites among asymptomatic individuals in Zanzibar. Methods HTP-LAMP performance was evaluated against real-time PCR on 3008 paired blood samples collected on filter papers in a commu...

  9. Field and laboratory comparative evaluation of rapid malaria diagnostic tests versus traditional and molecular techniques in India

    Directory of Open Access Journals (Sweden)

    Bharti Praveen K

    2010-07-01

    Full Text Available Abstract Background Malaria presents a diagnostic challenge in most tropical countries. Microscopy remains the gold standard for diagnosing malaria infections in clinical practice and research. However, microscopy is labour intensive, requires significant skills and time, which causes therapeutic delays. The objective of obtaining result quickly from the examination of blood samples from patients with suspected malaria is now made possible with the introduction of rapid malaria diagnostic tests (RDTs. Several RDTs are available, which are fast, reliable and simple to use and can detect Plasmodium falciparum and non-falciparum infections or both. A study was conducted in tribal areas of central India to measure the overall performance of several RDTs for diagnosis of P. falciparum and non-falciparum infections in comparison with traditional and molecular techniques. Such data will be used to guide procurement decisions of policy makers and programme managers. Methods Five commercially available RDTs were tested simultaneously in field in parallel with peripheral blood smears in outbreak-affected areas. The evaluation is designed to provide comparative data on the performance of each RDT. In addition, molecular method i.e. polymerase chain reaction (PCR was also carried out to compare all three methods. Results A total of 372 patients with a clinical suspicion of malaria from Bajag Primary Health Centre (PHC of district Dindori and Satanwada PHC of district Shivpuri attending the field clinics of Regional Medical Research Centre were included in the study. The analysis revealed that the First Response Malaria Antigen pLDH/HRP2 combo test was 94.7% sensitive (95% CI 89.5-97.7 and 69.9% specific (95% CI 63.6-75.6 for P. falciparum. However, for non-falciparum infections (Plasmodium vivax the test was 84.2% sensitive (95% CI 72.1-92.5 and 96.5% specific (95% CI 93.8-98.2. The Parascreen represented a good alternative. All other RDTs were relatively

  10. Evaluation and Tests

    Science.gov (United States)

    ... University of Utah Research News Make a Difference Evaluation + Tests Print This Page Before diagnosing peripheral neuropathy, ... from any type of neuropathy or neurological disorder. Evaluation A neurological evaluation consists of a physical exam ...

  11. Comparative evaluation of bivalent malaria rapid diagnostic tests versus traditional methods in field with special reference to heat stability testing in Central India.

    Directory of Open Access Journals (Sweden)

    Neeru Singh

    Full Text Available BACKGROUND: Malaria presents a diagnostic challenge in areas where both Plasmodium falciparum and P.vivax are co-endemic. Bivalent Rapid Diagnostic tests (RDTs showed promise as diagnostic tools for P.falciparum and P.vivax. To assist national malaria control programme in the selection of RDTs, commercially available seven malaria RDTs were evaluated in terms of their performance with special reference to heat stability. METHODOLOGY/PRINCIPAL FINDINGS: This study was undertaken in four forested districts of central India (July, 2011- March, 2012. All RDTs were tested simultaneously in field along with microscopy as gold standard. These RDTs were stored in their original packing at 25°C before transport to the field or they were stored at 35°C and 45°C upto 100 days for testing the performance of RDTs at high temperature. In all 2841 patients with fever were screened for malaria of which 26% were positive for P.falciparum, and 17% for P.vivax. The highest sensitivity of any RDT for P.falciparum was 98% (95% CI; 95.9-98.8 and lowest sensitivity was 76% (95% CI; 71.7-79.6. For P.vivax highest and lowest sensitivity for any RDT was 80% (95% CI; 94.9 - 83.9 and 20% (95% CI; 15.6-24.5 respectively. Heat stability experiments showed that most RDTs for P.falciparum showed high sensitivity at 45°C upto 90 days. While for P.vivax only two RDTs maintained good sensitivity upto day 90 when compared with RDTs kept at room temperature. Agreement between observers was excellent for positive and negative readings for both P.falciparum and P.vivax (Kappa >0.6-0.9. CONCLUSION: This is first field evaluation of RDTs regarding their temperature stability. Although RDTs are useful as diagnostic tool for P.falciparum and P.vivax even at high temperature, the quality of RDTs should be regulated and monitored more closely.

  12. SEURAT: Safety Evaluation Ultimately Replacing Animal Testing – Recommendations for future research in the field of predictive toxicology

    Science.gov (United States)

    The development of non-animal methodology to evaluate the potential for a chemical to cause systemic toxicity is one of the grand challenges of modern science. The European research programme SEURAT is active in this field and will conclude its first phase, SEURAT-1, in December ...

  13. Language Test Construction and Evaluation.

    Science.gov (United States)

    Alderson, J. Charles; And Others

    The guide is intended for teachers who must construct language tests and for other professionals who may need to construct, evaluate, or use the results of language tests. Most examples are drawn from the field of English-as-a-Second-Language instruction in the United Kingdom, but the principles and practices described may be applied to the…

  14. Evaluation of Immunoassays and General Biological Indicator Tests for Field Screening of Bacillus anthracis and Ricin

    Energy Technology Data Exchange (ETDEWEB)

    Bartholomew, Rachel A.; Ozanich, Richard M.; Arce, Jennifer S.; Engelmann, Heather E.; Heredia-Langner, Alejandro; Hofstad, Beth A.; Hutchison, Janine R.; Jarman, Kristin; Melville, Angela M.; Victry, Kristin D.; Bruckner-Lea, Cynthia J.

    2017-02-01

    The goal of this testing was to evaluate the ability of currently available commercial off-the-shelf (COTS) biological indicator tests and immunoassays to detect Bacillus anthracis (Ba) spores and ricin. In general, immunoassays provide more specific identification of biological threats as compared to indicator tests [3]. Many of these detection products are widely used by first responders and other end users. In most cases, performance data for these instruments are supplied directly from the manufacturer, but have not been verified by an external, independent assessment [1]. Our test plan modules included assessments of inclusivity (ability to generate true positive results), commonly encountered hoax powders (which can cause potential interferences or false positives), and estimation of limit of detection (LOD) (sensitivity) testing.

  15. Field evaluation of a rapid immunochromatographic dipstick test for the diagnosis of cholera in a high-risk population

    Directory of Open Access Journals (Sweden)

    Park Taesung

    2006-02-01

    Full Text Available Abstract Background Early detection of cholera outbreaks is crucial for the implementation of the most appropriate control strategies. Methods The performance of an immunochromatographic dipstick test (Institute Pasteur, Paris, France specific for Vibrio cholerae O1 was evaluated in a prospective study in Beira, Mozambique, during the 2004 cholera season (January-May. Fecal specimens were collected from 391 patients with acute watery nonbloody diarrhea and tested by dipstick and conventional culture. Results The overall sensitivity and specificity of the rapid test compared to culture were 95% (95% confidence interval [CI]: 91%–99% and 89% (95% CI: 86%–93%, respectively. After stratification by type of sample (rectal swab/bulk stool and severity of diarrhea, the sensitivity ranged between 85% and 98% and specificity between 77% and 97%. Conclusion This one-step dipstick test performed well in the diagnosis of V. cholerae O1 in a setting with seasonal outbreaks where rapid tests are most urgently needed.

  16. Evaluation of the 8310-N-S manufactured by Sutron–Results of bench, temperature, and field deployment testing

    Science.gov (United States)

    Kunkle, Gerald A.

    2016-01-07

    The Sutron 8310-N-S (8310) data collection platform (DCP) manufactured by Sutron Corporation was evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) for conformance to the manufacturer’s specifications for recording and transmitting data. The 8310-N-S is a National Electrical Manufacturers Association (NEMA)-enclosed DCP with a built-in Geostationary Operational Environmental Satellite transmitter that operates over a temperature range of −40 to 60 degrees Celsius (°C). The evaluation procedures followed and the results obtained are described in this report for bench, temperature chamber, and outdoor deployment testing. The three units tested met the manufacturer’s stated specifications for the tested conditions, but two of the units had transmission errors either during temperature chamber or deployment testing. During outdoor deployment testing, 6.72 percent of transmissions by serial number 1206109 contained errors, resulting in missing data. Transmission errors were also observed during temperature chamber testing with serial number 1208283, at an error rate of 3.22 percent. Overall, the 8310 has good logging capabilities, but the transmission errors are a concern for users who require reliable telemetered data.

  17. Safety Evaluation of Self-assembling Peptide Gel after Intracranial Administration to Rats Using the Open Field Test.

    Science.gov (United States)

    Tsunoda, Masashi; Sugaya, Chiemi; Sugiura, Yumiko; Nagai, Yusuke; Sakanishi, Kotaro

    2016-01-01

    Self-assembling peptides have been developed as clinical materials, which could scaffold to regenerate nerve cells and hemostatic materials in vivo. However, there has not been enough information for their in vivo application. The safety of self-assembling peptides for the application on the brain was examined using behavioral tests for each rat in this study. Self-assembling peptide gel was administered to the surface of the brain at a volume of 20 µL at 1.5%. After 2 months, the open field test and the prepulse inhibition (PPI) test were performed. There were no significant differences between the peptide gel and the control groups in locomotor distances and in %PPIs in the PPI test. The mean values of the percentage of time the rats stayed in the central area of the open field during the first 5 min and instances of center rearing or face washing in the peptide gel group were significantly higher than those in the control. There were amorphous substance in the subarachnoid region, and infiltrations of mononuclear cells were also observed in the self-assembling peptide gel group. Although the meaning of the effects observed in this study was not fully elucidated, the self-assembling gel produced marginal but significant behavioral and histological effects.

  18. Field Evaluation of a High Throughput Loop Mediated Isothermal Amplification Test for the Detection of Asymptomatic Plasmodium Infections in Zanzibar.

    Science.gov (United States)

    Aydin-Schmidt, Berit; Morris, Ulrika; Ding, Xavier C; Jovel, Irina; Msellem, Mwinyi I; Bergman, Daniel; Islam, Atiqul; Ali, Abdullah S; Polley, Spencer; Gonzalez, Iveth J; Mårtensson, Andreas; Björkman, Anders

    2017-01-01

    New field applicable diagnostic tools are needed for highly sensitive detection of residual malaria infections in pre-elimination settings. Field performance of a high throughput DNA extraction system for loop mediated isothermal amplification (HTP-LAMP) was therefore evaluated for detecting malaria parasites among asymptomatic individuals in Zanzibar. HTP-LAMP performance was evaluated against real-time PCR on 3008 paired blood samples collected on filter papers in a community-based survey in 2015. The PCR and HTP-LAMP determined malaria prevalences were 1.6% (95%CI 1.3-2.4) and 0.7% (95%CI 0.4-1.1), respectively. The sensitivity of HTP-LAMP compared to PCR was 40.8% (CI95% 27.0-55.8) and the specificity was 99.9% (CI95% 99.8-100). For the PCR positive samples, there was no statistically significant difference between the geometric mean parasite densities among the HTP-LAMP positive (2.5 p/μL, range 0.2-770) and HTP-LAMP negative (1.4 p/μL, range 0.1-7) samples (p = 0.088). Two lab technicians analysed up to 282 samples per day and the HTP-LAMP method was experienced as user friendly. Although field applicable, this high throughput format of LAMP as used here was not sensitive enough to be recommended for detection of asymptomatic low-density infections in areas like Zanzibar, approaching malaria elimination.

  19. Data acquisition and evaluation analysis on advanced high-efficiency energy system field test project (fiscal 2000); 2000 nendo sendoteki kokoritsu energy system field test jigyo ni okeru data shuyaku oyobi hyoka kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Field tests have been performed on the next generation phosphoric acid fuel cell power generation systems to collect and analyze the long-term operation data and trouble cases by introducing the final proliferation pattern into the actual demand on a trial basis. This paper reports the achievements in fiscal 2000. The locations of executing the field tests in fiscal 2000 are the 15 sites, including the NTT Central Training Center, and the Environment and Energy Exploratirium. Measurements were carried out at each test site on fuel gas consumption, fuel cell output power amount, utilized quantity of heat at low temperatures, utilized quantity of heat at elevated temperatures, and discarded quantity of heat. In addition, the total demand power amount and the shutdown information were also put into order. As a result of the evaluation analysis, the second factory of Senhoku Manufactory recorded the longest operation time of 23,777 hours, whose operation factor has reached 92%. Five systems had the continuous operation time exceeded 5,000 hours. The power generation efficiency was about 40% in a system using the town gas 13A fuel, wherein the total efficiency was 90% or greater. The largest number of failures in fiscal 2000 was seven at Tochigi Factory of Kirin Brewery, whose average number of failure was 1.6 a year. (NEDO)

  20. Field testing, refinement, and psychometric evaluation of a new measure of quality of care for assisted living.

    Science.gov (United States)

    Rantz, Marilyn J; Aud, Myra A; Zwygart-Stauffacher, Mary; Mehr, David R; Petroski, Gregory F; Owen, Steven V; Madsen, Richard W; Flesner, Marcia; Conn, Vicki; Maas, Meridean

    2008-01-01

    Field test results are reported for the Observable Indicators of Nursing Home Care Quality Instrument-Assisted Living Version, an instrument designed to measure the quality of care in assisted living facilities after a brief 30-minute walk-through. The OIQ-AL was tested in 207 assisted-living facilities in two states using classical test theory, generalizability theory, and exploratory factor analysis. The 34-item scale has a coherent six-factor structure that conceptually describes the multidimensional concept of care quality in assisted living. The six factors can be logically clustered into process (Homelike and Caring, 21 items) and structure (Access and Choice; Lighting; Plants and Pets; Outdoor Spaces) subscales and for a total quality score. Classical test theory results indicate most subscales and the total quality score from the OIQ-AL have acceptable interrater, test-retest, and strong internal consistency reliabilities. Generalizability theory analyses reveal that dependability of scores from the instrument are strong, particularly by including a second observer who conducts a site visit and independently completes an instrument, or by a single observer conducting two site visits and completing instruments during each visit. Scoring guidelines based on the total sample of observations (N = 358) help guide those who want to use the measure to interpret both subscale and total scores. Content validity was supported by two expert panels of people experienced in the assisted-living field, and a content validity index calculated for the first version of the scale is high (3.43 on a four-point scale). The OIQ-AL gives reliable and valid scores for researchers, and may be useful for consumers, providers, and others interested in measuring quality of care in assisted-living facilities.

  1. Small wind turbine performance evaluation using field test data and a coupled aero-electro-mechanical model

    Science.gov (United States)

    Wallace, Brian D.

    A series of field tests and theoretical analyses were performed on various wind turbine rotor designs at two Penn State residential-scale wind-electric facilities. This work involved the prediction and experimental measurement of the electrical and aerodynamic performance of three wind turbines; a 3 kW rated Whisper 175, 2.4 kW rated Skystream 3.7, and the Penn State designed Carolus wind turbine. Both the Skystream and Whisper 175 wind turbines are OEM blades which were originally installed at the facilities. The Carolus rotor is a carbon-fiber composite 2-bladed machine, designed and assembled at Penn State, with the intent of replacing the Whisper 175 rotor at the off-grid system. Rotor aerodynamic performance is modeled using WT_Perf, a National Renewable Energy Laboratory developed Blade Element Momentum theory based performance prediction code. Steady-state power curves are predicted by coupling experimentally determined electrical characteristics with the aerodynamic performance of the rotor simulated with WT_Perf. A dynamometer test stand is used to establish the electromechanical efficiencies of the wind-electric system generator. Through the coupling of WT_Perf and dynamometer test results, an aero-electro-mechanical analysis procedure is developed and provides accurate predictions of wind system performance. The analysis of three different wind turbines gives a comprehensive assessment of the capability of the field test facilities and the accuracy of aero-electro-mechanical analysis procedures. Results from this study show that the Carolus and Whisper 175 rotors are running at higher tip-speed ratios than are optimum for power production. The aero-electro-mechanical analysis predicted the high operating tip-speed ratios of the rotors and was accurate at predicting output power for the systems. It is shown that the wind turbines operate at high tip-speeds because of a miss-match between the aerodynamic drive torque and the operating torque of the wind

  2. Evaluation of the Field Performance of ImmunoCard STAT!(®) Rapid Diagnostic Test for Rotavirus in Dadaab Refugee Camp and at the Kenya-Somalia Border.

    Science.gov (United States)

    Ope, Maurice; Nyoka, Raymond; Unshur, Ahmed; Oyier, Fredrick O; Mowlid, Shafe A; Owino, Brian; Ochieng, Steve B; Okello, Charles I; Montgomery, Joel M; Wagacha, Burton; Galev, Aleksandar; Abdow, Abdikadir; Esona, Mathew D; Tate, Jacqueline; Fitter, David; Cookson, Susan T; Arunmozhi, Balajee; Marano, Nina

    2017-06-01

    AbstractRotavirus commonly causes diarrhea in children, leading to hospitalization and even death. Rapid diagnostic tests are feasible alternatives for determining rotavirus outbreaks in refugee camps that have inadequate laboratory capacity. We evaluated the field performance of ImmunoCard STAT!(®) Rotavirus (ICS-RV) in Dadaab Refugee Camp and at the Kenya-Somalia border. From May to December 2014, we prospectively enrolled children aged tested by trained surveillance clerks using ICS-RV per manufacturer's instructions. The field performance characteristics of ICS-RV were evaluated against the gold standard test, Premier(™) Rotaclone(®) enzyme immunoassay. The operational characteristics were evaluated using World Health Organization (WHO) ASSURED criteria to determine whether ICS-RV is appropriate as a point-of-care test by administering a standard questionnaire and observing surveillance clerks performing the test. We enrolled 213 patients with a median age of 10 months (range = 1-48); 58.2% were male. A total of 71 (33.3%) and 60 (28.2%) patients tested positive for rotavirus infection by immunoassay and ICS-RV, respectively. The sensitivity, specificity, and positive and negative predictive values of ICS-RV compared with the immunoassay were 83.1% (95% confidence interval [CI] = 72.3-91.0), 99.3% (95% CI = 96.1-100), 98.3% (95% CI = 91.1-100), and 92.1% (95% CI = 86.6-95.5), respectively. The ICS-RV fulfilled the WHO ASSURED criteria for point-of-care testing. ICS-RV is a field-ready point-of-care test with good field performance and operational characteristics. It can be useful in determining rotavirus outbreaks in resource-limited settings.

  3. Field Evaluation of a High Throughput Loop Mediated Isothermal Amplification Test for the Detection of Asymptomatic Plasmodium Infections in Zanzibar

    Science.gov (United States)

    Morris, Ulrika; Ding, Xavier C.; Jovel, Irina; Msellem, Mwinyi I.; Bergman, Daniel; Islam, Atiqul; Ali, Abdullah S.; Polley, Spencer; Gonzalez, Iveth J.; Mårtensson, Andreas; Björkman, Anders

    2017-01-01

    Background New field applicable diagnostic tools are needed for highly sensitive detection of residual malaria infections in pre-elimination settings. Field performance of a high throughput DNA extraction system for loop mediated isothermal amplification (HTP-LAMP) was therefore evaluated for detecting malaria parasites among asymptomatic individuals in Zanzibar. Methods HTP-LAMP performance was evaluated against real-time PCR on 3008 paired blood samples collected on filter papers in a community-based survey in 2015. Results The PCR and HTP-LAMP determined malaria prevalences were 1.6% (95%CI 1.3–2.4) and 0.7% (95%CI 0.4–1.1), respectively. The sensitivity of HTP-LAMP compared to PCR was 40.8% (CI95% 27.0–55.8) and the specificity was 99.9% (CI95% 99.8–100). For the PCR positive samples, there was no statistically significant difference between the geometric mean parasite densities among the HTP-LAMP positive (2.5 p/μL, range 0.2–770) and HTP-LAMP negative (1.4 p/μL, range 0.1–7) samples (p = 0.088). Two lab technicians analysed up to 282 samples per day and the HTP-LAMP method was experienced as user friendly. Conclusions Although field applicable, this high throughput format of LAMP as used here was not sensitive enough to be recommended for detection of asymptomatic low-density infections in areas like Zanzibar, approaching malaria elimination. PMID:28095434

  4. Evaluating thermal resource partitioning : By sympatric lizards Anolis cooki and A. cristatellus: a field test using null hypotheses.

    Science.gov (United States)

    Hertz, P E

    1992-04-01

    The field thermal biology of sympatric Anolis cooki and A. cristatellus were evaluated in January and in August in desert scrub forest at Playa de Tamarindo near Guanica, Puerto Rico. Data on randomly positioned copper models of lizards, each equipped with a built-in thermocouple, established null hypotheses about basking frequency and operative temperatures (T e) against which the behavior and body temperatures (T b) of live lizards were evaluated. Both species exhibited non-random hourly basking rates (more marked in cristatellus than in cooki), and cristatellus was virtually inactive during the warm mid-day hours. The relationship between lizards' T b and randomly sampled T e differed between the species: cristatellus's mean T b was 2° to 3° C lower than randomly sampled mean T e in both months, whereas cooki's mean T b was slightly higher than mean T e in January and slightly lower in August. Although cooki's mean T b was higher than that of cristatellus in both months, the T b's of the two species overlapped substantially over an annual cycle. Given the similarities in their field active T b and the low thermal heterogeneity among microsites at Playa de Tamarindo, these species appear not to partition the thermal environment there in a coarse-grained way. Instead, the relatively small differences in their field active T b probably result from small differences in their use of similar microhabitats within their mutually exclusive territories. Thermal resource partitioning by territorial animals is unlikely unless thermal heterogeneity is coarse-grained in relation to territory size.

  5. Field Test Evaluation of Conservation Retrofits of Low-Income Single Family Buildings in Wisconsin: Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Ternes, M.P.

    2001-05-21

    During the winter of 1985-86, a retrofit field test was performed in 66 occupied, low-income, single-family homes in Madison, Wisconsin. The primary objectives of the field test were to (1) determine the measured energy savings and the relative benefits of a combination of envelope and mechanical equipment retrofits that were selected following a new audit-directed retrofit procedure, (2) determine the energy savings and benefits due to performing infiltration reduction work following a recently developed infiltration reduction procedure, and (3) study general occupant behavior and house thermal characteristics and their possible change following retrofit installation. This report provides an overview of the project and summarizes the findings which will be presented in detail in separate reports. Major findings from the field test include: (1) The audit-directed retrofit procedure produced an average savings of 207 therms/year/house. The procedure also more than doubled the overall cost-effectiveness of the low-income weatherization assistance program as compared with the priority system formerly used in Wisconsin. Wall insulation and condensing furnaces were the major retrofits (predicted annual energy savings greater than 100 therms/year) most often selected under the procedure. The respective average energy savings of the houses receiving wall insulation and condensing furnace. s was 14.6 and 14.3 therms/year for each $100 spent on them under the program. (2) The blower-door-guided infiltration reduction procedure reduced expenditures for infiltration reduction to about one-fourth of previous program costs (from $570/house to $106/house). The procedure also reduced the average air leakage rate in the treated houses by 16%, whereas, in a previous study, no significant reduction was found following the installation of typical infiltration reduction measures. (3) Twenty to 60% of the deviation between predicted and measured savings can be attributed to incorrect

  6. Evaluation of the Storm 3 data logger manufactured by WaterLOG/Xylem Incorporated—Results of bench, temperature, and field deployment testing

    Science.gov (United States)

    Kunkle, Gerald A.

    2016-05-04

    The Storm 3 is a browser-based data logger manufactured by WaterLOG/Xylem Incorporated that operates over a temperature range of −40 to 60 degrees Celsius (°C). A Storm logger with no built-in telemetry (Storm3-00) and a logger with built-in cellular modem (Storm3-03) were evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) for conformance to the manufacturer’s specifications with bench tests, for recording data over the device’s operating temperature range with temperature chamber tests, and for field performance with an outdoor deployment test.

  7. Performance Evaluation of Advanced Retrofit Roof Technologies Using Field-Test Data Phase Three Final Report, Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, Kaushik [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Phillip W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    This article presents some miscellaneous data from two low-slope and two steep-slope experimental roofs. The low-slope roofs were designed to compare the performance of various roof coatings exposed to natural weatherization. The steep-slope roofs contained different combinations of phase change material, rigid insulation, low emittance surface and above-sheathing ventilation, with standing-seam metal panels on top. The steep-slope roofs were constructed on a series of adjacent attics separated at the gables using thick foam insulation. This article describes phase three (3) of a study that began in 2009 to evaluate the energy benefits of a sustainable re-roofing technology utilizing standing-seam metal roofing panels combined with energy efficient features like above-sheathing-ventilation (ASV), phase change material (PCM) and rigid insulation board. The data from phases 1 and 2 have been previously published and reported [Kosny et al., 2011; Biswas et al., 2011; Biswas and Childs, 2012; Kosny et al., 2012]. Based on previous data analyses and discussions within the research group, additional test roofs were installed in May 2012, to test new configurations and further investigate different components of the dynamic insulation systems. Some experimental data from phase 3 testing from May 2012 to December 2013 and some EnergyPlus modeling results have been reported in volumes 1 and 3, respectively, of the final report [Biswas et al., 2014; Biswas and Bhandari, 2014].

  8. Ada Test and Evaluation.

    Science.gov (United States)

    1980-05-01

    Lady Lovelace , the daughter of the poet, Lord Byron. Ada was Charles Babbage’s programmer, Babbage being the inventor of the first mechanical...34 O-07 0 ARFOCERIGTAEOAUIAL LABS RIGHTPATTERSON AFB OH F/G 9/2 ADA TEST AND EVALUATION.(U) MAY BO A J SCARPELLI UNCLASSIFIED AFWAL-TR-BO-1024 NL E...llEllllEIlE III HA i28 5__ BIH~~ ~ 2 __I.,11 LZ AFAL-TR-80-1024 Ada TEST AND EVALUATION Alfred J. Scarpelli System Technology Branch Systen Avionics

  9. Test methods for evaluating solid waste. Volume 1A through 1C, and Volume 2. Field manual physical/chemical methods (3rd edition)

    Energy Technology Data Exchange (ETDEWEB)

    1986-09-01

    This manual provides test procedures that may be used to evaluate those properties of a solid waste that determine whether the waste is a hazardous waste within the definition of Section 3001 of the Resource Conservation and Recovery Act (PL 94-580). These methods are approved for obtaining data to satisfy the requirement of 40 CFR Part 261, Identification and Listing of Hazardous Waste. Volume IA deals with quality control, selection of appropriate test methods, and analytical methods for metallic species. Volume IB consists of methods for organic analytes. Volume IC includes a variety of test methods for miscellaneous analytes and properties for use in evaluating the waste characteristics. Volume II deals with sample acquisition and includes quality control, sampling-plan design and implementation, and field-sampling methods.

  10. Field Evaluation of a Coproantigen Detection Test for Fascioliasis Diagnosis and Surveillance in Human Hyperendemic Areas of Andean Countries

    Science.gov (United States)

    Valero, María Adela; Periago, María Victoria; Pérez-Crespo, Ignacio; Angles, René; Villegas, Fidel; Aguirre, Carlos; Strauss, Wilma; Espinoza, José R.; Herrera, Patricia; Terashima, Angelica; Tamayo, Hugo; Engels, Dirk; Gabrielli, Albis Francesco; Mas-Coma, Santiago

    2012-01-01

    Background Emergence of human fascioliasis prompted a worldwide control initiative including a pilot study in a few countries. Two hyperendemic areas were chosen: Huacullani, Northern Altiplano, Bolivia, representing the Altiplanic transmission pattern with high prevalences and intensities; Cajamarca valley, Peru, representing the valley pattern with high prevalences but low intensities. Coprological sample collection, transport and study procedures were analyzed to improve individual diagnosis and subsequent treatments and surveillance activities. Therefore, a coproantigen-detection technique (MM3-COPRO ELISA) was evaluated, using classical techniques for egg detection for comparison. Methodology and Findings A total of 436 and 362 stool samples from schoolchildren of Huacullani and Cajamarca, respectively, were used. Positive samples from Huacullani were 24.77% using the MM3-COPRO technique, and 21.56% using Kato-Katz. Positive samples from Cajamarca were 11.05% using MM3-COPRO, and 5.24% using rapid sedimentation and Kato-Katz. In Huacullani, using Kato-Katz as gold standard, sensitivity and specificity were 94.68% and 98.48%, respectively, and using Kato-Katz and COPRO-ELISA test together, they were 95.68% and 100%. In Cajamarca, using rapid sedimentation and Kato-Katz together, results were 94.73% and 93.58%, and using rapid sedimentation, Kato-Katz and copro-ELISA together, they were 97.56% and 100%, respectively. There was no correlation between coproantigen detection by optical density (OD) and infection intensity by eggs per gram of feces (epg) in Cajamarca low burden cases (<400 epg), nor in Huacullani high burden cases (≥400 epg), although there was in Huacullani low burden cases (<400 epg). Six cases of egg emission appeared negative by MM3-COPRO, including one with a high egg count (1248 epg). Conclusions The coproantigen-detection test allows for high sensitivity and specificity, fast large mass screening capacity, detection in the chronic phase

  11. Field evaluation of a coproantigen detection test for fascioliasis diagnosis and surveillance in human hyperendemic areas of Andean countries.

    Directory of Open Access Journals (Sweden)

    María Adela Valero

    Full Text Available BACKGROUND: Emergence of human fascioliasis prompted a worldwide control initiative including a pilot study in a few countries. Two hyperendemic areas were chosen: Huacullani, Northern Altiplano, Bolivia, representing the Altiplanic transmission pattern with high prevalences and intensities; Cajamarca valley, Peru, representing the valley pattern with high prevalences but low intensities. Coprological sample collection, transport and study procedures were analyzed to improve individual diagnosis and subsequent treatments and surveillance activities. Therefore, a coproantigen-detection technique (MM3-COPRO ELISA was evaluated, using classical techniques for egg detection for comparison. METHODOLOGY AND FINDINGS: A total of 436 and 362 stool samples from schoolchildren of Huacullani and Cajamarca, respectively, were used. Positive samples from Huacullani were 24.77% using the MM3-COPRO technique, and 21.56% using Kato-Katz. Positive samples from Cajamarca were 11.05% using MM3-COPRO, and 5.24% using rapid sedimentation and Kato-Katz. In Huacullani, using Kato-Katz as gold standard, sensitivity and specificity were 94.68% and 98.48%, respectively, and using Kato-Katz and COPRO-ELISA test together, they were 95.68% and 100%. In Cajamarca, using rapid sedimentation and Kato-Katz together, results were 94.73% and 93.58%, and using rapid sedimentation, Kato-Katz and copro-ELISA together, they were 97.56% and 100%, respectively. There was no correlation between coproantigen detection by optical density (OD and infection intensity by eggs per gram of feces (epg in Cajamarca low burden cases (<400 epg, nor in Huacullani high burden cases (≥ 400 epg, although there was in Huacullani low burden cases (<400 epg. Six cases of egg emission appeared negative by MM3-COPRO, including one with a high egg count (1248 epg. CONCLUSIONS: The coproantigen-detection test allows for high sensitivity and specificity, fast large mass screening capacity, detection in the

  12. Leaching Test Relationships, Laboratory-to-Field Comparisons and Recommendations for Leaching Evaluation using the Leaching Environmental Assessment Framework (LEAF)

    Science.gov (United States)

    This report presents examples of the relationships between the results of laboratory leaching tests, as defined by the Leaching Environmental Assessment Framework (LEAF) or analogous international test methods, and leaching of constituents from a broad range of materials under di...

  13. Remote field eddy current testing

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Y. M.; Jung, H. K.; Huh, H.; Lee, Y. S.; Shim, C. M

    2001-03-01

    The state-of-art technology of the remote field eddy current, which is actively developed as an electromagnetic non-destructive testing tool for ferromagnetic tubes, is described. The historical background and recent R and D activities of remote-field eddy current technology are explained including the theoretical development of remote field eddy current, such as analytical and numerical approach, and the results of finite element analysis. The influencing factors for actual applications, such as the effect of frequency, magnetic permeability, receiving sensitivity, and difficulties of detection and classification of defects are also described. Finally, two examples of actual application, 1) the gap measurement between pressure tubes and calandria tube in CANDU reactor and, 2) the detection of defects in the ferromagnetic heat exchanger tubes, are described. The future research efforts are also included.

  14. Field and Evaluation Methods Used to Test the Performance of a Stormceptor® Class 1 Stormwater Treatment Device in Australia

    Directory of Open Access Journals (Sweden)

    Peter Nichols

    2015-12-01

    Full Text Available Field testing of a proprietary stormwater treatment device was undertaken over 14 months at a site located in Nambour, South East Queensland. Testing was undertaken to evaluate the pollution removal performance of a Stormceptor® treatment train for removing total suspended solids (TSS, total nitrogen (TN and total phosphorous (TP from stormwater runoff. Water quality sampling was undertaken using natural rainfall events complying with an a priori sampling protocol. More than 59 rain events were monitored, of which 18 were found to comply with the accepted sampling protocol. The efficiency ratios (ER observed for the treatment device were found to be 83% for TSS, 11% for TP and 23% for TN. Although adequately removing TSS, additional system components, such as engineered filters, would be required to satisfy minimum local pollution removal regulations. The results of dry weather sampling tests did not conclusively demonstrate that pollutants were exported between storm events or that pollution concentrations increased significantly over time.

  15. Comparative evaluation of a field-based dot-ELISA kit with three other serological tests for the detection of Brucella antibodies in goats.

    Science.gov (United States)

    Singh, S V; Gupta, V K; Singh, N

    2000-06-01

    A dot-ELISA (d-ELISA) test was evaluated and compared with the serum agglutination test (SAT), micro-complement fixation test (CFT) and a plate-ELISA (p-ELISA) for field use in screening herds of goats against brucellosis. During the standardization of the dot-ELISA kit on 1732 caprine serum samples, 1571 samples out of 1666 were found to be negative in d-ELISA, SAT and micro-CFT, while 59 were positive in different combinations. Of a further 66 serum samples, 34 were negative and 31 were positive in different combinations in d-ELISA, SAT, micro-CFT and p-ELISA. A total of 1584 goats belonging to different herds were then screened for brucellosis. Of the 694 serum samples screened in the first batch using d-ELISA, a positive reaction was observed in 26 cases. Further screening of these cases revealed 13 and 21 goats as positive reactors in SAT and CFT, respectively. In a second batch of 890 goats there were 109 positive reactors in d-ELISA. Among these 109 goats, 34, 40 and 80 goats were positive reactors in SAT, CFT and p-ELISA, respectively. The results of d-ELISA correlated well with those of p-ELISA. Dot-ELISA was found to be a more suitable and rapid test for screening large numbers of goats in the field.

  16. Performance Evaluation of Advanced Retrofit Roof Technologies Using Field-Test Data Phase Three Final Report, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, Kaushik [ORNL; Childs, Phillip W [ORNL; Atchley, Jerald Allen [ORNL

    2014-05-01

    This article presents various metal roof configurations that were tested at Oak Ridge National Laboratory in Tennessee, U.S.A. between 2009 and 2013, and describes their potential for reducing the attic-generated space conditioning loads. These roofs contained different combinations of phase change material, rigid insulation, low emittance surface and above-sheathing ventilation, with standing-seam metal panels on top. These roofs were designed to be installed on existing roofs decks, or on top of asphalt shingles for retrofit construction. All the tested roofs showed the potential for substantial energy savings compared to an asphalt shingle roof, which was used as a control for comparison. The roofs were constructed on a series of adjacent attics separated at the gables using thick foam insulation. The attics were built on top of a conditioned room. All attics were vented at the soffit and ridge. The test roofs and attics were instrumented with an array of thermocouples. Heat flux transducers were installed in the roof deck and attic floor (ceiling) to measure the heat flows through the roof and between the attic and conditioned space below. Temperature and heat flux data were collected during the heating, cooling and swing seasons over a 3 year period. Data from previous years of testing have been published. Here, data from the latest roof configurations being tested in year 3 of the project are presented. All test roofs were highly effective in reducing the heat flows through the roof and ceiling, and in reducing the diurnal attic temperature fluctuations.

  17. Differential Expression of Whitebacked Planthopper Resistance in the japonica/indica Doubled Haploid Rice Population under Field Evaluation and Seedbox Screening Test

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Whitebacked planthopper (WBPH) -resistance in a japonica / indica doubled haploid (DH) rice population established from a cross between WBPH-resistant japonica Chunjiang 06 and susceptible indica TN1, was comparatively evaluated through a field experiment based on the WBPH immigrant density and standardized seedbox screening test (SSST). All the susceptible DH lines in the field experiment behaved accordingly in SSST. However, 35 of resistant 66 lines (53%) in the field, were categorized to susceptible groups in SSST. Likewise, there were no significant differences in WBPH immigrant densities among 70 DH lines that were highly resistant to susceptible in SSST. The results revealed that SSST could not evaluate properly WBPH resistance in the DH lines. Four QTLs for WBPH-resistance phenotyped by the immigrant density were detected on chromosomes 2, 3, 4, and 11. Of them, the QTL on chromosome 4 was the most effective (LOD 21.8, variance 78%). Five QTLs associated with seedling mortality were mapped on chromosomes 2, 3, 4, 5 and 6. In addition to the QTL (LOD 10.5, variance 68%) on chromosome 4, there was another major QTL (LOD 12.7, variance 71%) located on chromosome 5, which was SSST-specific but might be irrespective of the WBPH resistance traits.

  18. Behaviour observation during conformation evaluation at field test for Danish Warmblood horses and associations to rideability and performance traits

    DEFF Research Database (Denmark)

    Nielsen, Janne Rothmann; Christensen, Ole Fredslund; Søndergaard, Eva

    2014-01-01

    videotaped and scored for reactivity during the evaluation of their conformation, and a questionnaire was completed by the owners. Associations between reactivity and performance traits were investigated by computing partial correlations (Pearson, rp). A low negative correlation was found between rideability...... association was found between reactivity and ratings from owners (rp = 0.15, P = .02), indicating that horses considered to be nervous by their owners also were scored as reactive. In conclusion, it appears possible to measure reactivity in a practical situation. This study also concluded low negative...

  19. Field trial evaluation of the performances of point-of-care tests for screening G6PD deficiency in Cambodia.

    Directory of Open Access Journals (Sweden)

    Arantxa Roca-Feltrer

    Full Text Available User-friendly, accurate, point-of-care rapid tests to detect glucose-6-phosphate dehydrogenase deficiency (G6PDd are urgently needed at peripheral level to safely recommend primaquine for malaria elimination.The CareStart G6PD RDT (AccessBio, New Jersey, USA, a novel rapid diagnostic test and the most commonly used test, the fluorescent spot test (FST were assessed against the quantitatively measured G6PD enzyme activity for detecting G6PDd. Subjects were healthy males and non-pregnant females aged 18 years or older residing in six villages in Pailin Province, western Cambodia.Of the 938 subjects recruited, 74 (7.9% were severe and moderately severe G6PD deficient (enzyme activity <30%, mostly in male population; population median G6PD activity was 12.0 UI/g Hb. The performances of the CareStart G6PD RDT and the FST, according to different cut-off values used to define G6PDd were very similar. For the detection of severe and moderately severe G6PDd (enzyme activity < 30%, < 3.6 UI/g Hb in males and females, sensitivity and negative (normal status predictive value were 100% for both point-of-care tools. When the G6PDd cut-off value increased (from < 40% to < 60%, the sensitivity for both PoCs decreased: 93.3% to 71.7% (CareStart G6PD RDT, p = 10(-6 and 95.5% to 73.2% (FST, p = 10(-6 while the specificity for both PoCs remained similar: 97.4% to 98.3% (CareStart G6PD RDT, p = 0.23 and 98.7% to 99.6% (FST, p = 0.06. The cut-off values for classifying individuals as normal were 4.0 UI/g Hb and 4.3 UI/g Hb for the CareStart G6PD RDT and the FST, respectively.The CareStart G6PD RDT reliably detected moderate and severe G6PD deficient individuals (enzyme activity <30%, suggesting that this novel point-of-care is a promising tool for tailoring appropriate primaquine treatment for malaria elimination by excluding individuals with severe G6PDd for primaquine treatment.

  20. A Cochlear Implant Performance Prognostic Test Based on Electrical Field Interactions Evaluated by eABR (Electrical Auditory Brainstem Responses.

    Directory of Open Access Journals (Sweden)

    Nicolas Guevara

    Full Text Available Cochlear implants (CIs are neural prostheses that have been used routinely in the clinic over the past 25 years. They allow children who were born profoundly deaf, as well as adults affected by hearing loss for whom conventional hearing aids are insufficient, to attain a functional level of hearing. The "modern" CI (i.e., a multi-electrode implant using sequential coding strategies has yielded good speech comprehension outcomes (recognition level for monosyllabic words about 50% to 60%, and sentence comprehension close to 90%. These good average results however hide a very important interindividual variability as scores in a given patients' population often vary from 5 to 95% in comparable testing conditions. Our aim was to develop a prognostic model for patients with unilateral CI. A novel method of objectively measuring electrical and neuronal interactions using electrical auditory brainstem responses (eABRs is proposed.The method consists of two measurements: 1 eABR measurements with stimulation by a single electrode at 70% of the dynamic range (four electrodes distributed within the cochlea were tested, followed by a summation of these four eABRs; 2 Measurement of a single eABR with stimulation from all four electrodes at 70% of the dynamic range. A comparison of the eABRs obtained by these two measurements, defined as the monaural interaction component (MIC, indicated electrical and neural interactions between the stimulation channels. Speech recognition performance without lip reading was measured for each patient using a logatome test (64 "vowel-consonant-vowel"; VCV; by forced choice of 1 out of 16. eABRs were measured in 16 CI patients (CIs with 20 electrodes, Digisonic SP; Oticon Medical ®, Vallauris, France. Significant correlations were found between speech recognition performance and the ratio of the amplitude of the V wave of the eABRs obtained with the two measurements (Pearson's linear regression model, parametric correlation: r

  1. Evaluation of two counterflow traps for testing behaviour-mediating compounds for the malaria vector Anopheles gambiae s.s. under semi-field conditions in Tanzania

    NARCIS (Netherlands)

    Schmied, W.H.; Takken, W.; Killeen, G.F.; Knols, B.G.J.; Smallegange, R.C.

    2008-01-01

    Background Evaluation of mosquito responses towards different trap-bait combinations in field trials is a time-consuming process that can be shortened by experiments in contained semi-field systems. Possible use of the BG Sentinel (BGS) trap to sample Anopheles gambiae s.s. was evaluated. The

  2. Field test for progesterone : an interim evaluation of the sol particle agglutination inhibition assay = Veldtest voor progesteron : een tussentijdse evaluatie van de sol partikel agglutinatie inhibitie test

    NARCIS (Netherlands)

    Davina, J.H.M.

    1987-01-01

    In dit rapport wordt een agglutinatie-test geevalueerd als een variant van de predictor-test voor het controleren van de vruchtbaarheid van grote landbouwhuisdieren. De bepalingsmethode berust op een koppeling van antilichamen tegen progesteron met minuscule gouddeeltjes die in gevriesdroogde toesta

  3. Resilient Modulus of Freeze-Thaw Affected Granular Soils for Pavement Design and Evaluation. Part 2. Field Validation Tests at Winchendon, Massachusetts, Test Sections,

    Science.gov (United States)

    1986-10-01

    techniques to express the resil- on the riding qualities, integrity , and durability of ient modulus Mr as a function of density, soil pavements are...in the second series of tests in ciated instrumentation integrates the velocity sig- February 1979, when the test soils were frozen. As nal and reads...analysis of the six test sections are sum- Radius (m) •0 0 2 04 0 6 08 1 0 o E 400 Actual Basin - -- j/ / Calculoated Baosin 00 .. ~~~~~ ~~1200 1 1

  4. Evaluation and Tests

    Science.gov (United States)

    ... and other reflexes. Sensations in the feet and hands will be evaluated with a pin. Since some neuropathies are hereditary, you doctor will ask if other members of your family have suffered from any type of neuropathy or neurological disorder. Evaluation A neurological evaluation consists of a ...

  5. Online Reading Test Evaluation

    Institute of Scientific and Technical Information of China (English)

    雷鸣

    2011-01-01

    Language test has been used as a scientific assessment tool in providing valuable information for teaching and learning. In fact,lots of online reading tests are not designed with validity. This paper analyzes those online reading tests from the aspects o

  6. Test & Evaluation Management Guide

    Science.gov (United States)

    2012-12-01

    conducted, using munitions likely to be encountered in combat, on a complete system loaded or equipped with all the dangerous materials that normally would...systems, work scope, contracting approaches, efficiency, requirements creep , and risk management. 15.11.3 Agile Development and Testing Testing within an...White Sands Missile Range, New Mexico, aerodynamic simulations of the proposed test were run on a computer during actual firings so that real-time

  7. Image quality evaluation of light field photography

    Science.gov (United States)

    Fu, Qiang; Zhou, Zhiliang; Yuan, Yan; Xiangli, Bin

    2011-01-01

    Light field photography captures 4D radiance information of a scene. Digital refocusing and digital correction of aberrations could be done after the photograph is taken. However, capturing 4D light field is costly and tradeoffs between different image quality metrics should be made and evaluated. This paper explores the effects of light field photography on image quality by quantitatively evaluating some basic criteria for an imaging system. A simulation approach was first developed by ray-tracing a designed light field camera. A standard testing chart followed by ISO 12233 was provided as the input scene. A sequence of light field raw images were acquired and processed by light field rendering methods afterwards. Through-focus visual resolution and MTF were calculated and analyzed. As a comparison, the same tests were taken for the same main lens system as the results of conventional photography. An experimental light field system was built up and its performance was tested. This work helps better understanding the pros and cons of light field photography in contrast with conventional imaging methods and perceiving the way to optimize the joint digital-optical design of the system.

  8. Comparative evaluation of chest radiography, low-field MRI, the Shwachman-Kulczycki score and pulmonary function tests in patients with cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Anjorin, Angela; Vogl, Thomas J. [Johann Wolfgang Goethe University, Institute for Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Schmidt, Helga [Johann Wolfgang Goethe University, Department of Pediatric Radiology, Institute for Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Posselt, Hans-Georg [Johann Wolfgang Goethe University, Clinics for Pediatry, Gastroenterology, Frankfurt am Main (Germany); Smaczny, Christina [Johann Wolfgang Goethe University, Medical Clinics I, Pneumology, Frankfurt am Main (Germany); Ackermann, Hanns [Johann Wolfgang Goethe University, Department of Biomathematics, Frankfurt am Main (Germany); Deimling, Michael [Siemens Medical Solutions, Erlangen (Germany); Abolmaali, Nasreddin [Dresden University of Technology, OncoRay - Molecular Imaging, Medical Faculty Carl Gustav Carus, Dresden (Germany)

    2008-06-15

    The aim of this study was to investigate whether the parenchymal lung damage in patients suffering from cystic fibrosis (CF) can be equivalently quantified by the Chrispin-Norman (CN) scores determined with low-field magnetic resonance imaging (MRI) and conventional chest radiography (CXR). Both scores were correlated with pulmonary function tests (PFT) and the Shwachman-Kulczycki method (SKM). To evaluate the comparability of MRI and CXR for different states of the disease, all scores were applied to patients divided into three age groups. Seventy-three CF patients (mean SKM score: 62 {+-} 8) with a median age (range) of 14 years (7-32) were included. The mean CN scores determined with both imaging methods were comparable (CXR: 12.1 {+-} 4.7; MRI: 12.0 {+-} 4.5) and showed high correlation (P < 0.05, R = 0.97). Only weak correlations were found between imaging, PFT, and SKM. Both imaging modalities revealed significantly more severe disease expression with age, while PFT and SKM failed to detect early signs of disease. We conclude that imaging of the lung in CF patients is capable of detecting subtle and early parenchymal destruction before lung function or clinical scoring is affected. Furthermore, low-field MRI revealed high consistency with chest radiography and may be used for a thorough follow-up while avoiding radiation exposure. (orig.)

  9. Deep Borehole Field Test Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Ernest L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-09-30

    This report documents conceptual design development for the Deep Borehole Field Test (DBFT), including test packages (simulated waste packages, not containing waste) and a system for demonstrating emplacement and retrieval of those packages in the planned Field Test Borehole (FTB). For the DBFT to have demonstration value, it must be based on conceptualization of a deep borehole disposal (DBD) system. This document therefore identifies key options for a DBD system, describes an updated reference DBD concept, and derives a recommended concept for the DBFT demonstration. The objective of the DBFT is to confirm the safety and feasibility of the DBD concept for long-term isolation of radioactive waste. The conceptual design described in this report will demonstrate equipment and operations for safe waste handling and downhole emplacement of test packages, while contributing to an evaluation of the overall safety and practicality of the DBD concept. The DBFT also includes drilling and downhole characterization investigations that are described elsewhere (see Section 1). Importantly, no radioactive waste will be used in the DBFT, nor will the DBFT site be used for disposal of any type of waste. The foremost performance objective for conduct of the DBFT is to demonstrate safe operations in all aspects of the test.

  10. Evaluation of light microscopy and rapid diagnostic test for the detection of malaria under operational field conditions: a household survey in Ethiopia

    Directory of Open Access Journals (Sweden)

    Yohannes Gedeon

    2008-07-01

    Full Text Available Abstract Background In most resource-poor settings, malaria is usually diagnosed based on clinical signs and symptoms and not by detection of parasites in the blood using microscopy or rapid diagnostic tests (RDT. In population-based malaria surveys, accurate diagnosis is important: microscopy provides the gold standard, whilst RDTs allow immediate findings and treatment. The concordance between RDTs and microscopy in low or unstable transmission areas has not been evaluated. Objectives This study aimed to estimate the prevalence of malaria parasites in randomly selected malarious areas of Amhara, Oromia, and Southern Nations, Nationalities and Peoples' (SNNP regions of Ethiopia, using microscopy and RDT, and to investigate the agreement between microscopy and RDT under field conditions. Methods A population-based survey was conducted in 224 randomly selected clusters of 25 households each in Amhara, Oromia and SNNP regions, between December 2006 and February 2007. Fingerpick blood samples from all persons living in even-numbered households were tested using two methods: light microscopy of Giemsa-stained blood slides; and RDT (ParaScreen device for Pan/Pf. Results A total of 13,960 people were eligible for malaria parasite testing of whom 11,504 (82% were included in the analysis. Overall slide positivity rate was 4.1% (95% confidence interval [CI] 3.4–5.0% while ParaScreen RDT was positive in 3.3% (95% CI 2.6–4.1% of those tested. Considering microscopy as the gold standard, ParaScreen RDT exhibited high specificity (98.5%; 95% CI 98.3–98.7 and moderate sensitivity (47.5%; 95% CI 42.8–52.2 with a positive predictive value of 56.8% (95% CI 51.7–61.9 and negative predictive value of 97.6% (95% CI 97.6–98.1% under field conditions. Conclusion Blood slide microscopy remains the preferred option for population-based prevalence surveys of malaria parasitaemia. The level of agreement between microscopy and RDT warrants further

  11. In Situ Field Testing of Processes

    Energy Technology Data Exchange (ETDEWEB)

    J. Wang

    2001-12-14

    The purpose of this Analysis/Model Report (AMR) is to update and document the data and subsequent analyses from ambient field-testing activities performed in underground drifts of the Yucca Mountain Site Characterization Project (YMP). This revision updates data and analyses presented in the initial issue of this AMR. This AMR was developed in accordance with the ''Technical Work Plan for Unsaturated Zone (UZ) Flow and Transport Process Model Report'' and ''Technical Work Plan for UZ Flow, Transport, and Coupled Processes Process Model Report. These activities were performed to investigate in situ flow and transport processes. The evaluations provide the necessary framework to: (1) refine and confirm the conceptual model of matrix and fracture processes in the unsaturated zone (UZ) and (2) analyze the impact of excavation (including use of construction water and effect of ventilation) on the UZ flow and transport processes. This AMR is intended to support revisions to ''Conceptual and Numerical Models for UZ Flow and Transport'' and ''Unsaturated Zone Flow and Transport Model Process Model Report''. In general, the results discussed in this AMR are from studies conducted using a combination or a subset of the following three approaches: (1) air-injection tests, (2) liquid-release tests, and (3) moisture monitoring using in-drift sensors or in-borehole sensors, to evaluate the impact of excavation, ventilation, and construction-water usage on the surrounding rocks. The liquid-release tests and air-injection tests provide an evaluation of in situ fracture flow and the competing processes of matrix imbibition. Only the findings from testing and data not covered in the ''Seepage Calibration Model and Seepage Testing Data'' are analyzed in detail in the AMR.

  12. FY1992 research report on the evaluation and analysis of data collected in fuel cell power generation field test project; 1992 nendo nenryo denchi hatsuden field test jigyo ni okeru shushu data hyoka kaiseki kenkyu hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-03-01

    This paper describes the achievements in fiscal 1992 in the field tests on fuel cell power generation systems. The three locations subjected to the present analysis are all installed with 50-kW systems, whereas power generation efficiency of around 35% such as 35.3, 34.2 and 34.6% was obtained when the systems were operated at the rated output. When the load gets to below a certain load band (about 30 kW), the power generation efficiency decreases proportionately with the load. The overall efficiency including heat supply was 77.8, 70.7 and 80.3% respectively at about the rated output, showing a trend that the higher the thermal efficiency, the higher the overall efficiency. The case of generating both electric power and heat simultaneously has higher efficiency than the case of heat supply alone. The contribution rate of the fuel cell as a base load was 2.8, 4.6 and 13.6%, respectively. The system with as high value as 13.6% takes a power load following type operation mode, in which power is generated during a time band with large load during weekdays, and no power is generated at nighttime and in holidays when load is smaller, playing a role of peak responding power supply. Only one trouble has occurred in an auxiliary generator in the heat recovery system. (NEDO)

  13. Deep Borehole Field Test Laboratory and Borehole Testing Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlman, Kristopher L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brady, Patrick V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); MacKinnon, Robert J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Heath, Jason E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Herrick, Courtney G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jensen, Richard P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gardner, W. Payton [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sevougian, S. David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bryan, Charles R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jang, Je-Hun [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stein, Emily R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bauer, Stephen J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Daley, Tom [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Freifeld, Barry M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Birkholzer, Jens [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Spane, Frank A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-19

    Deep Borehole Disposal (DBD) of high-level radioactive wastes has been considered an option for geological isolation for many years (Hess et al. 1957). Recent advances in drilling technology have decreased costs and increased reliability for large-diameter (i.e., ≥50 cm [19.7”]) boreholes to depths of several kilometers (Beswick 2008; Beswick et al. 2014). These advances have therefore also increased the feasibility of the DBD concept (Brady et al. 2009; Cornwall 2015), and the current field test design will demonstrate the DBD concept and these advances. The US Department of Energy (DOE) Strategy for the Management and Disposal of Used Nuclear Fuel and High-Level Radioactive Waste (DOE 2013) specifically recommended developing a research and development plan for DBD. DOE sought input or expression of interest from States, local communities, individuals, private groups, academia, or any other stakeholders willing to host a Deep Borehole Field Test (DBFT). The DBFT includes drilling two boreholes nominally 200m [656’] apart to approximately 5 km [16,400’] total depth, in a region where crystalline basement is expected to begin at less than 2 km depth [6,560’]. The characterization borehole (CB) is the smaller-diameter borehole (i.e., 21.6 cm [8.5”] diameter at total depth), and will be drilled first. The geologic, hydrogeologic, geochemical, geomechanical and thermal testing will take place in the CB. The field test borehole (FTB) is the larger-diameter borehole (i.e., 43.2 cm [17”] diameter at total depth). Surface handling and borehole emplacement of test package will be demonstrated using the FTB to evaluate engineering feasibility and safety of disposal operations (SNL 2016).

  14. Field evaluation of the InBios Chagas detect plus rapid test in serum and whole-blood specimens in Bolivia.

    Science.gov (United States)

    Shah, Vishal; Ferrufino, Lisbeth; Gilman, Robert H; Ramirez, Margot; Saenza, Eliana; Malaga, Edith; Sanchez, Gerardo; Okamoto, Emi E; Sherbuck, Jacqueline E; Clark, Eva H; Galdos-Cardenas, Gerson; Bozo, Ricardo; Flores-Franco, Jorge Luis; Colanzi, Rony; Verastegui, Manuela; Bern, Caryn

    2014-12-01

    Trypanosoma cruzi causes Chagas disease, which affects an estimated 7 million to 8 million people. Chagas disease is endemic throughout Latin America, with the highest prevalence in Bolivia. Conventional diagnosis requires a well-equipped laboratory with experienced personnel. We evaluated the Chagas Detect Plus (CDP) (InBios, Seattle, WA), a rapid immunochromatographic assay for IgG antibodies to T. cruzi. CDP performance was compared to infection status based on results obtained by indirect hemagglutination assay, immunofluorescent-antibody test, and enzyme-linked immunosorbent assay. Confirmed infection required positive results by at least 2 conventional assays. We used specimens from adults of both sexes in a general hospital in the city of Santa Cruz and from pregnant women in a hospital and children in villages in the Bolivian Chaco, an area of hyperendemicity. CDP was performed in paired whole-blood and serum specimens from 385 individuals in the two hospital studies and in 200 serum specimens from the community study. CDP showed sensitivities/specificities of 96.2% (95% confidence interval, 92.7 to 98.4)/98.8% (95.9 to 99.9) in whole blood and 99.3% (97.5 to 99.9)/96.9% (94.2 to 98.6) in serum, with no differences by sex, age group, or study site. CDP showed excellent sensitivity and specificity in our study population, comparable to those of conventional serology. The test is reliable for field surveys, requires no laboratory equipment, and performed well in serum and whole blood. The CDP could also be used for accurate maternal screening to identify neonates at risk of congenital transmission. CDP performance data in diverse geographic areas are needed to strengthen the evidence base for its use. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  15. Evaluation of PV Module Field Performance

    Energy Technology Data Exchange (ETDEWEB)

    Wohlgemuth, John; Silverman, Timothy; Miller, David C.; McNutt, Peter; Kempe, Michael; Deceglie, Michael

    2015-06-14

    This paper describes an effort to inspect and evaluate PV modules in order to determine what failure or degradation modes are occurring in field installations. This paper will report on the results of six site visits, including the Sacramento Municipal Utility District (SMUD) Hedge Array, Tucson Electric Power (TEP) Springerville, Central Florida Utility, Florida Solar Energy Center (FSEC), the TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification.

  16. Advanced Vehicle Testing and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Garetson, Thomas [The Clarity Group, Incorporated, Chicago, IL (United States)

    2013-03-31

    The objective of the United States (U.S.) Department of Energy's (DOEs) Advanced Vehicle Testing and Evaluation (AVTE) project was to provide test and evaluation services for advanced technology vehicles, to establish a performance baseline, to determine vehicle reliability, and to evaluate vehicle operating costs in fleet operations.Vehicles tested include light and medium-duty vehicles in conventional, hybrid, and all-electric configurations using conventional and alternative fuels, including hydrogen in internal combustion engines. Vehicles were tested on closed tracks and chassis dynamometers, as well as operated on public roads, in fleet operations, and over prescribed routes. All testing was controlled by procedures developed specifically to support such testing.

  17. Advanced Vehicle Testing and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Garetson, Thomas [The Clarity Group, Incorporated, Chicago, IL (United States)

    2013-03-31

    The objective of the United States (U.S.) Department of Energy's (DOEs) Advanced Vehicle Testing and Evaluation (AVTE) project was to provide test and evaluation services for advanced technology vehicles, to establish a performance baseline, to determine vehicle reliability, and to evaluate vehicle operating costs in fleet operations.Vehicles tested include light and medium-duty vehicles in conventional, hybrid, and all-electric configurations using conventional and alternative fuels, including hydrogen in internal combustion engines. Vehicles were tested on closed tracks and chassis dynamometers, as well as operated on public roads, in fleet operations, and over prescribed routes. All testing was controlled by procedures developed specifically to support such testing.

  18. Test and Evaluation Management Guide

    Science.gov (United States)

    1993-08-01

    requirements and specifications of the contract. (2) Identify operational deficiencies; Postproduction testing requirements may (3) Recommend and evaluate...objectives to evaluateTHE PRODUCTION AND DE PRODMENTIOHAND postproduction logistics readiness and sup- DEPLOYMENT PHASE port are to:(MS III to MS IV) After...does, however, in- grated Logistics Support Plan (ILSP), etc.) clude a requirement for postproduction that are also in early stages of develop- test

  19. CHARM Facility Test Area Radiation Field Description

    CERN Document Server

    Thornton, Adam

    2016-01-01

    Specification document summarising the radiation field of the CHARM facility test area. This will act as a guide to any potential users of the facility as to what they can expect in terms of radiation, given in the form of radiation spectra information and fluence for each test position, along with general radiation maps for the test area and Montrac test location.

  20. 3X-100 blade field test.

    Energy Technology Data Exchange (ETDEWEB)

    Zayas, Jose R.; Johnson, Wesley D.

    2008-03-01

    In support of a Work-For-Other (WFO) agreement between the Wind Energy Technology Department at Sandia National Laboratories and 3TEX, one of the three Micon 65/13M wind turbines at the USDA Agriculture Research Service (ARS) center in Bushland, Texas, has been used to test a set of 9 meter wind turbine blades, manufactured by TPI composites using the 3TEX carbon material for the spar cap. Data collected from the test has been analyzed to evaluate both the aerodynamic performance and the structural response from the blades. The blades aerodynamic and structural performance, the meteorological inflow and the wind turbine structural response has been monitored with an array of 57 instruments: 15 to characterize the blades, 13 to characterize inflow, and 15 to characterize the time-varying state of the turbine. For the test, data was sampled at a rate of 40 Hz using the ATLAS II (Accurate GPS Time-Linked Data Acquisition System) data acquisition system. The system features a time-synchronized continuous data stream and telemetered data from the turbine rotor. This paper documents the instruments and infrastructure that have been developed to monitor these blades, turbines and inflow, as well as both modeling and field testing results.

  1. In situ, field-scale evaluation of surfactant-enhanced DNAPL recovery using a single-well, ``push-pull'' test

    Energy Technology Data Exchange (ETDEWEB)

    Istok, J.D.; Field, J.A.

    1999-10-01

    The overall goal of this project was to further develop the single-well, ``push-pull'' test method as a feasibility assessment and site-characterization tool for studying the fundamental fate and transport behavior of injected surfactants and their ability to solubilize and mobilize dense nonaqueous phase liquids (DNAPLs) in the subsurface. The specific objectives were to develop a modified push-pull test for use in identifying and quantifying the effects of sorption, precipitation, and biodegradation on the fate and transport of injected surfactants, use the developed test method to quantify the effects of these processes on the ability of injected surfactants to solubilize and mobilize residual phase trichloroethane (TCE), and demonstrate the utility of the developed test method for performing site characterization and feasibility studies for surfactant-enhanced DNAPL recovery systems in the field. The results from the intermediate-scale laboratory experiments conducted for this project indicate that the single-well, push-pull test method can provide quantitative information on the effectiveness of injected surfactants in enhancing DNAPL solubilization in natural aquifer sediments. Specifically, the results of this research demonstrate the ability of the single-well, push-pull test to characterize the behavior of multi-component surfactants in the presence of natural aquifer sediment under laboratory and in-situ field conditions.

  2. Test fields cannot destroy extremal black holes

    Science.gov (United States)

    Natário, José; Queimada, Leonel; Vicente, Rodrigo

    2016-09-01

    We prove that (possibly charged) test fields satisfying the null energy condition at the event horizon cannot overspin/overcharge extremal Kerr-Newman or Kerr-Newman-anti de Sitter black holes, that is, the weak cosmic censorship conjecture cannot be violated in the test field approximation. The argument relies on black hole thermodynamics (without assuming cosmic censorship), and does not depend on the precise nature of the fields. We also discuss generalizations of this result to other extremal black holes.

  3. IN SITU FIELD TESTING OF PROCESSES

    Energy Technology Data Exchange (ETDEWEB)

    J.S.Y. YANG

    2004-11-08

    The purpose of this scientific analysis report is to update and document the data and subsequent analyses from ambient field-testing activities performed in underground drifts and surface-based boreholes through unsaturated zone (UZ) tuff rock units. In situ testing, monitoring, and associated laboratory studies are conducted to directly assess and evaluate the waste emplacement environment and the natural barriers to radionuclide transport at Yucca Mountain. This scientific analysis report supports and provides data to UZ flow and transport model reports, which in turn contribute to the Total System Performance Assessment (TSPA) of Yucca Mountain, an important document for the license application (LA). The objectives of ambient field-testing activities are described in Section 1.1. This report is the third revision (REV 03), which supercedes REV 02. The scientific analysis of data for inputs to model calibration and validation as documented in REV 02 were developed in accordance with the Technical Work Plan (TWP) ''Technical Work Plan for: Performance Assessment Unsaturated Zone'' (BSC 2004 [DIRS 167969]). This revision was developed in accordance with the ''Technical Work Plan for: Unsaturated Zone Flow Analysis and Model Report Integration'' (BSC 2004 [DIRS 169654], Section 1.2.4) for better integrated, consistent, transparent, traceable, and more complete documentation in this scientific analysis report and associated UZ flow and transport model reports. No additional testing or analyses were performed as part of this revision. The list of relevant acceptance criteria is provided by ''Technical Work Plan for: Unsaturated Zone Flow Analysis and Model Report Integration'' (BSC 2004 [DIRS 169654]), Table 3-1. Additional deviations from the TWP regarding the features, events, and processes (FEPs) list are discussed in Section 1.3. Documentation in this report includes descriptions of how, and under what

  4. Interactive Diagnostic Testing: Field Trial Results.

    Science.gov (United States)

    McArthur, David L.; Cabello, Beverly

    A diagnostic testing system managed by microcomputer was evaluated in actual use at the upper elementary level. Two tests specifically designed to yield diagnostic indicators of erroneous performance were utilized, one a test of pronoun usage, the other a test of reading comprehension. The results are interpreted from the standpoint of the…

  5. Development of an Evaluation System for Vertical Vibration of Railway Vehicles with Field-Portable Actuators (2nd Report, Excitation Tests of an Actual Commuter Vehicle)

    Science.gov (United States)

    Takigami, Tadao; Tomioka, Takahiro

    Bending vibration characteristics of railway vehicles have been investigated in general under excitation tests, in which a carbody was directly excited by a shaker. It is however very difficult with their results to evaluate the ride quality of passengers under conditions that the vehicle runs on a certain track. The authors are therefore developing an evaluation system for vertical vibration of railway vehicles. This system consists of an excitation system equipped with linear actuators, the elastic supporting device installed between wheels and rails, and analytical techniques to estimate the power spectral density (PSD) and the ride quality level (LT) which feature the ride quality. In this paper, we describe the excitation tests performed using an actual commuter car and the estimated PSD and LT are compared with what substantially measured under the running conditions.

  6. Field-based evaluation of a reagent strip test for diagnosis of Schistosomiasis mansoni by detecting circulating cathodic antigen (CCA in urine in low endemic area in Ethiopia

    Directory of Open Access Journals (Sweden)

    Legesse M.

    2008-06-01

    Full Text Available The sensitivity, specificity, positive and negative predictive values of a reagent strip test for the diagnosis of schistosomiasis mansoni by detecting circulating cathodic antigen (CCA in urine were evaluated using 184 stool and urine samples collected from schoolchildren living in relatively low endemic area of schistosomiasis mansoni in Ethiopia. A combined result of stool samples processed by Kato and formol-ether concentration methods was used as gold standard. The results showed that detection of CCA in urine using reagent strip test was slightly higher than the combined results of the stool techniques (65.2% vs 42.4%, p > 0.05 in suggesting the prevalence of the disease. The sensitivity, specificity, positive and negative predictive values of the reagent strip test were 76.9%, 43.4%, 50% and 71.9%, respectively. The result of egg counts using Kato method suggested that detection of urine CCA could be used to indicate the intensity of infection. Nevertheless, like that of stool examination, the reagent strip test was found to be less sensitive in case of light to moderate infections. About 23.1% of the study children who were excreting the eggs of the parasite were found negative by the reagent strip test. The relative insensitivity of a reagent strip test in low intensity of infection necessitates for the development of more sensitive assay that can truly discriminate schistosome-infected from non-infected individuals.

  7. Evaluation of the Radiochemistry of Near-Field Water Samples at the Nevada Test Site Applied to the Definition of a Hydrologic Source Term

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D K

    2002-07-05

    Effective management of available groundwater resources and strategies for remediation of water impacted by past nuclear testing practices depend on knowledge about the migration of radionuclides in groundwater away from the sites of the explosions. A primary concern is to assess the relative mobilities of the different radionuclide species found near sites of underground nuclear tests and to determine the concentration, extent, and speed of this movement. Ultimately the long term transport behavior of radionuclides with half-lives long enough that they will persist for decades, their interaction with groundwater, and the resulting flux of these contaminants is of paramount importance. As part of a comprehensive approach to these assessments, more than three decades of site-specific sites studies have been undertaken at the Nevada Test Site (NTS) which have focused on the means responsible for the observed or suspected movement of radionuclides away from underground nuclear tests (RNM, 1983). More recently regional and local models of groundwater flow and radionuclide transport have been developed as part of a federal and state of Nevada program to assess the long-term effects of underground nuclear testing on human health and environment (e.g., U.S. DOE/NV, 1997a; Tompson et al., 1999; Pawloski et al., 2001). Necessary to these efforts is a reliable measure of the hydrologic source term which is defined as those radionuclides dissolved in or otherwise transported by groundwater (Smith et al., 1995). Measurement of radionuclides in waters sampled near the sites of underground nuclear test provides arguably the best opportunity to bound the hydrologic source term. This empirical approach was recognized early and concentration data has been collected annually since mid-1970's. Initially three sites were studied at the NTS; over the years the program has been expanded to include more than fifteen study locations. As part of various field programs, Lawrence

  8. Field Guide to Interferometric Optical Testing

    CERN Document Server

    Goodwin, Eric P

    2006-01-01

    A distillation of Dr. Wyant's course at the University of Arizona, this Field Guide covers the key fundamentals of interferometry, types of interferometers and interferograms, concepts of phase-shifting interferometry, long-wavelength interferometry, testing of aspheric surfaces, measurement of surface microstructure, flat and curved surface testing, and absolute measurements.

  9. Efficacy of the repellent N,N-diethyl-3-methyl-benzamide (DEET) against tabanid flies on horses evaluated in a field test in Switzerland.

    Science.gov (United States)

    Herholz, C; Kopp, C; Wenger, M; Mathis, A; Wägeli, S; Roth, N

    2016-05-15

    Female tabanid flies (Diptera: Tabanidae) can be a serious nuisance for horses because of their painful bites during blood feeding. They also play a primary role in mechanical transmission of a lentivirus causing Equine Infectious Anemia (EIA), a virus that has spread within Europe in recent years. According to the European law for products intended for use as a repellent on horses (recreational and sport horses), a field test is mandatory to demonstrate sufficient repellency of such a substance against the specific target fly species, but currently no agreed protocols are available for testing of potential repellents. The aim of the present study was to establish a protocol for a field test to investigate the efficacy of N,N-diethyl-3-methyl-benzamide (DEET, Brum®, Huebeli-Stud Horse Care AG) in a 15-17% oil-water emulsion against tabanid flies on horses up to four hours. Between July and August 2015, four horses on three farms each were tested on two consecutive days in a cross-over design. The four horses on Farm A were used in the pre-test as well as in the main test. Two and a half hours after repellent application the horses were lunged until sweating. Tabanid fly infestations were both photographed and directly counted during five minutes 3 and 4h after repellent application on the right side of the horses in the area from the head to the flank, belly and first third of the foreleg. Without repellent application, up to 29 tabanid flies were counted on a horse, whereas the maximum for the repellent treated horses was four. In 50% of the horses treated with DEET there were no Tabanids observed (efficacy 100%), and in all horses the tabanid fly counts were lower than in the control horses with one exemption at 4h. The efficacy of the DEET repellent was at least 80% and 71% respectively, three or four hours after application (with a confidence level of 89%). A fly trap (Horse Pal) revealed the presence of the tabanid species Tabanus brominus and Haematopota

  10. Rapid Field Toxicity Test for Water Supplies

    Science.gov (United States)

    1994-02-28

    of trichothecenes (2). The correlation of the novel method with the Mysid trichothecenes paper described a perfect qualitative shrimp test, using fresh...test designed for human or animal consumption. organisms in a standard time LED light emitting diode CONCLUSION ml milliliter ppm parts per million A...potassium. of Trichothecenes ," Naval Research Laboratory Memorwdm Report 5738 (March 1986) Logistics dictate a day or so to test field samples in the

  11. Nuclear explosives testing readiness evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Valk, T.C.

    1993-09-01

    This readiness evaluation considers hole selection and characterization, verification, containment issues, nuclear explosive safety studies, test authorities, event operations planning, canister-rack preparation, site preparation, diagnostic equipment setup, device assembly facilities and processes, device delivery and insertion, emplacement, stemming, control room activities, readiness briefing, arming and firing, test execution, emergency response and reentry, and post event analysis to include device diagnostics, nuclear chemistry, and containment. This survey concludes that the LLNL program and its supporting contractors could execute an event within six months of notification, and a second event within the following six months, given the NET group`s evaluation and the following three restraints: (1) FY94 (and subsequent year) funding is essentially constant with FY93, (2) Preliminary work for the initial event is completed to the historical sic months status, (3) Critical personnel, currently working in dual use technologies, would be recallable as needed.

  12. New Manning System Field Evaluation

    Science.gov (United States)

    1986-03-01

    our Analytic hodel (see Chapter 5, New Manning Svestem Field Evaluacion . Technical Revore No. I, RAJL-, November c t, e number or soldiers retaking...and meaningful performance measures are not only crucial to the WRAIR N Field Evaluacion but also to the Army. To know which unit does betzer than

  13. Evaluation of Cold Tolerance in Field Grown Mentha (Mentha piperita‎‏ L.‎ under ‎Laboratory Conditions by Electrolyte Leakage Test

    Directory of Open Access Journals (Sweden)

    T Kheirkhah

    2015-09-01

    Full Text Available In order to determine cold tolerance of field grown Mentha (Mentha Piperita L. under controlled conditions, using electrolyte leakage index, an experiment was carried out at the College of Agriculture, Ferdowsi University of Mashhad, based on a completely randomized design with four replications. Experimental factors included six freezing temperatures (Zero, -4, -8, -12, -16 and -20 °C, seven harvest ‎time (November, December, January, February, March, April and May and ‎four Peppermint organs (leaves, Stems, Stolons and Rhizomes. So, field grown ‎and acclimated Pepermint was harvested from the faculty field every month. ‎After separating the Peppermint organs, they were subjected to freezing ‎temperatures. The membrane stability index was measured through ‎electrolyte leakage (EL and also lethal temperature 50 ‎according to EL (LT50el was determined. The results showed that electrolyte leakages were affected significantly by freezing temperature. By reduction of freezing temperature electrolyte leakages percentage increased. Among different organs of peppermint, stolon and leaf were the most cold tolerant and the most cold sensitive according to EL and LT50el , respectively. Also cold tolerance varied according to different harvest time in all organs. However, in May, all organs had lowest cold tolerance. Also leaves and stolons had the highest and the lowest LT50el, respectively. For all organs the highest LT50el‎ was observed in May. According to the high correlation between electrolyte leakages percent and LT50el (r = 0.96**, it seems that using this index for evaluation of freezing tolerance injury in Mentha piperita could be useful.

  14. Background field coils for the High Field Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Zbasnik, J.P.; Cornish, D.N.; Scanlan, R.M.; Jewell, A.M.; Leber, R.L.; Rosdahl, A.R.; Chaplin, M.R.

    1980-09-22

    The High Field Test Facility (HFTF), presently under construction at LLNL, is a set of superconducting coils that will be used to test 1-m-o.d. coils of prototype conductors for fusion magnets in fields up to 12 T. The facility consists of two concentric sets of coils; the outer set is a stack of Nb-Ti solenoids, and the inner set is a pair of solenoids made of cryogenically-stabilized, multifilamentary Nb/sub 3/Sn superconductor, developed for use in mirror-fusion magnets. The HFTF system is designed to be parted along the midplane to allow high-field conductors, under development for Tokamak fusion machines, to be inserted and tested. The background field coils were wound pancake-fashion, with cold-welded joints at both the inner and outer diameters. Turn-to-turn insulation was fabricated at LLNL from epoxy-fiberglass strip. The coils were assembled and tested in our 2-m-diam cryostat to verify their operation.

  15. Combustion Safety Simplified Test Protocol Field Study

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L. [Gas Technology Inst., Des Plaines, IL (United States); Cautley, D. [Gas Technology Inst., Des Plaines, IL (United States); Bohac, D. [Gas Technology Inst., Des Plaines, IL (United States); Francisco, P. [Gas Technology Inst., Des Plaines, IL (United States); Shen, L. [Gas Technology Inst., Des Plaines, IL (United States); Gloss, S. [Gas Technology Inst., Des Plaines, IL (United States)

    2015-11-01

    Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project team collected field data on 11 houses in 2015.

  16. Evaluation of resistance in a selected field strain of Haemonchus contortus to ivermectin and moxidectin using the Larval Migration on Agar Test

    Directory of Open Access Journals (Sweden)

    Fernanda S. Fortes

    2013-02-01

    Full Text Available Haemonchus contortus is one of the most common and economically significant causes of disease in small ruminants worldwide, and the control programs of parasitic nematodes - including H. contortus - rely mostly on the use of anthelmintic drugs. The consequence of the use of this, as the sole sanitary strategy to avoid parasite infections, was the reduction of the efficacy of all chemotherapeutic products with a heavy selection for resistance. The widespread of anthelmintic resistance and the difficulty of its early diagnosis has been a major concern for the sustainable parasite management on farms. The objective of this research was to determine and compare the ivermectin (IVM and moxidectin (MOX effect in a selected field strain of H. contortus with a known resistance status, using the in vitro larval migration on agar test (LMAT. Third stage larvae of the selected isolate were obtained from faecal cultures of experimentally infected sheep and incubated in eleven increasing diluted concentrations of IVM and MOX (6, 12, 24, 48, 96, 192, 384, 768, 1536, 3072 and 6144µg/mL. The dose-response sigmoidal curves were obtained using the R² value of >0.90 and the lethal concentration (LC50 dose for the tested anthelmintic drugs using a four-parameter logistic model. The LC50 value for MOX was significantly lower than IVM (1.253µg/mL and 91.06µg/mL, identifying the H. contortus isolate as considerably less susceptible to IVM compared to MOX. Furthermore, the LMAT showed a high consistency (p<0.0001 and provided to be a useful diagnostic tool for monitoring the resistance status of IVM and MOX in H. contortus field isolate, as well as it may be used for official routine drug monitoring programs under the Ministry of Agriculture (MAPA guidance.

  17. Results of the fourth Hanna field test

    Energy Technology Data Exchange (ETDEWEB)

    Covell, J. R.; Wojdac, L. F.; Barbour, F. A.; Gardner, G. W.; Glass, R.; Hommert, P. J.

    1980-01-01

    The second phase (Hanna IVB) of a coal gasification experiment near Hanna, Wyoming, was completed in September 1979. The experiment attempted to link and gasify coal between process wells spaced 34.3 meters apart. Intermediate wells were positioned between the process wells so that the link could be relayed over shorter distances. Reverse combustion linking was attempted over a 22.9-meter and a 11.4-meter distance of the total well spacing. Thermal activity was generally noted in the upper 3 meters of the coal seam during the link. Two attempts to gasify over the 34.3-meter distance resulted in the propagation of the burn front at the coal overburden interface. Post-burn evaluation indicates fractures as major influencing factors of the combustion process. The Hanna IVB field test provided much insight into influence that geologic features have on in situ coal combustion. The influence of these faults, permeable zones, and cleats, on the air flow patterns can drastically change the overall results of a gasification experiment and should be studied further. The overall results of Hanna IVB were discouraging because of the rapid decline in the heating values for the production gas and the amount of coal gasified. With more complete geologic characerization prior to experimentation and proper well completions, it is believed that most of the subsurface operational problems encountered during Hanna IV could have been avoided.

  18. Some Tests on Heather Field Moraine Clay

    DEFF Research Database (Denmark)

    Jørgensen, Mogens B.; Jacobsen, Moust

    This report deals with oedometer tests on three samples of moraine clay from the Heather Field in the English part of the North Sea. The tests have been carried out in the very unelastic apparatus used in Denmark and with special test procedures differing from the ones used elsewhere. In Denmark...... the English North Sea moraine clays with the corresponding Danish Moraine Clays. The Danish test procedures are explained in details and some comments are given in the hope that they may not be banalities all of them....

  19. Evaluating an Integrated Approach to the Management of Cerebral Palsy. Appendix B: Field Test Report of the Eau Claire Functional Abilities Test and the Wolfe-Bluel Socialization Inventory. Volume III of IV. Final Report.

    Science.gov (United States)

    Heal, Laird W.

    The appendix examined the measurement instruments developed in the course of the Integrated Management of Cerebral Palsy project to measure functional movements and socialization skills of severly handicapped, nonambulatory cerebral palsied children who had limited speech. The field test sample consisted of 51 cases for the Eau Claire Functional…

  20. Automated particulate sampler field test model operations guide

    Energy Technology Data Exchange (ETDEWEB)

    Bowyer, S.M.; Miley, H.S.

    1996-10-01

    The Automated Particulate Sampler Field Test Model Operations Guide is a collection of documents which provides a complete picture of the Automated Particulate Sampler (APS) and the Field Test in which it was evaluated. The Pacific Northwest National Laboratory (PNNL) Automated Particulate Sampler was developed for the purpose of radionuclide particulate monitoring for use under the Comprehensive Test Ban Treaty (CTBT). Its design was directed by anticipated requirements of small size, low power consumption, low noise level, fully automatic operation, and most predominantly the sensitivity requirements of the Conference on Disarmament Working Paper 224 (CDWP224). This guide is intended to serve as both a reference document for the APS and to provide detailed instructions on how to operate the sampler. This document provides a complete description of the APS Field Test Model and all the activity related to its evaluation and progression.

  1. Maximizing the chances of detecting pathogenic leptospires in mammals: the evaluation of field samples and a multi-sample-per-mammal, multi-test approach.

    Science.gov (United States)

    Tulsiani, S M; Graham, G C; Dohnt, M F; Burns, M-A; Craig, S B

    2011-03-01

    Identification of wild animals that harbour the causative leptospires, and the identification of the most important of these 'wild reservoirs' (in terms of threat to human health), are key factors in the epidemiology of human leptospirosis. In an epidemiological investigation in the Australian state of Queensland, in 2007-2008, samples were collected from fruit bats (Pteropus conspicillatus) and rodents (to investigate the potential role of fruit bats in the maintenance and transmission of leptospires to ground-dwelling rodents) and checked for pathogenic leptospires. The results of these studies have now been carefully analysed in attempts to see which method of detection and type of test sample were best. The effects of pentobarbitone sodium used to euthanize wild mammals before collection of necropsy samples, on the survival and detection of leptospires in vitro, were also explored. In the earlier field investigation, serum, renal tissue and urine were collected from wild mammals, for the detection of pathogenic leptospires by culture, the microscopic agglutination test (MAT), real-time PCR and silver impregnation of smears. Although 27.6% of the rodents investigated were found leptospire-positive, culture only yielded four isolates, probably because many cultures were contaminated. The main aims of the present study were to quantify the performance of the individual diagnostic tests and examine the reasons behind the high incidence of culture contamination. The results of sensitivity and specificity analyses for the different diagnostic tests indicated that isolation by culture (the definitive diagnostic test for leptospiral shedding) had perfect (100%) sensitivity when compared with the results of the PCR but a low specificity (40%). The MAT performed poorly, with a sensitivity of 50% when compared against the results of culture. The prevalence of leptospiral carriage revealed by the PCR-based investigation of kidney and urine samples (59.2%) was higher than

  2. Numerical simulations of capillary barrier field tests

    Energy Technology Data Exchange (ETDEWEB)

    Morris, C.E. [Univ. of Wollongong (Australia); Stormont, J.C. [Univ. of New Mexico, Albuquerque, NM (United States)

    1997-12-31

    Numerical simulations of two capillary barrier systems tested in the field were conducted to determine if an unsaturated flow model could accurately represent the observed results. The field data was collected from two 7-m long, 1.2-m thick capillary barriers built on a 10% grade that were being tested to investigate their ability to laterally divert water downslope. One system had a homogeneous fine layer, while the fine soil of the second barrier was layered to increase its ability to laterally divert infiltrating moisture. The barriers were subjected first to constant infiltration while minimizing evaporative losses and then were exposed to ambient conditions. The continuous infiltration period of the field tests for the two barrier systems was modelled to determine the ability of an existing code to accurately represent capillary barrier behavior embodied in these two designs. Differences between the field test and the model data were found, but in general the simulations appeared to adequately reproduce the response of the test systems. Accounting for moisture retention hysteresis in the layered system will potentially lead to more accurate modelling results and is likely to be important when developing reasonable predictions of capillary barrier behavior.

  3. Session: Test and Evaluation (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Marion, B.; Hanley, C.

    2008-04-01

    The overall goal of this presentation is: (1) provide test and evaluation of PV cells/modules/systems to TPP participants, other PV industry, labs, and universities in support of technology optimization efforts sponsored by DOE's Solar Program and the SAI; (2) support commercial and emerging technology development; (3) provide component and system performance data to improve and validate system performance models; (4) provide T and E support for reliability activities; and (5) priority is placed on TPP's and other solicitations.

  4. Field testing driver night vision devices

    NARCIS (Netherlands)

    Kooi, F.L.; Kolletzki, D.

    2007-01-01

    This paper summarizes the available methodologies to field test driver night vision devices ranging from vehicle mounted camera’s to head-mounted NVG’s. As in flight trials, a formidable challenge is to collect meaningful performance measures. Night vision systems for land and air systems show many

  5. Trip Report-Produced-Water Field Testing

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, Enid J. [Los Alamos National Laboratory

    2012-05-25

    Los Alamos National Laboratory (LANL) conducted field testing of a produced-water pretreatment apparatus with assistance from faculty at the Texas A&M University (TAMU) protein separation sciences laboratory located on the TAMU main campus. The following report details all of the logistics surrounding the testing. The purpose of the test was to use a new, commercially-available filter media housing containing modified zeolite (surfactant-modified zeolite or SMZ) porous medium for use in pretreatment of oil and gas produced water (PW) and frac-flowback waters. The SMZ was tested previously in October, 2010 in a lab-constructed configuration ('old multicolumn system'), and performed well for removal of benzene, toluene, ethylbenzene, and xylenes (BTEX) from PW. However, a less-expensive, modular configuration is needed for field use. A modular system will allow the field operator to add or subtract SMZ filters as needed to accommodate site specific conditions, and to swap out used filters easily in a multi-unit system. This test demonstrated the use of a commercial filter housing with a simple flow modification and packed with SMZ for removing BTEX from a PW source in College Station, Texas. The system will be tested in June 2012 at a field site in Pennsylvania for treating frac-flowback waters. The goals of this test are: (1) to determine sorption efficiency of BTEX in the new configuration; and (2) to observe the range of flow rates, backpressures, and total volume treated at a given flow rate.

  6. Evaluation of an exercise field test using heart rate monitors to assess cardiorespiratory fitness and heart rate recovery in an asymptomatic population.

    Directory of Open Access Journals (Sweden)

    Crystal L Coolbaugh

    Full Text Available PURPOSE: Measures of cardiorespiratory fitness (CRF and heart rate recovery (HRR can improve risk stratification for cardiovascular disease, but these measurements are rarely made in asymptomatic individuals due to cost. An exercise field test (EFT to assess CRF and HRR would be an inexpensive method for cardiovascular disease risk assessment in large populations. This study assessed 1 the predictive accuracy of a 12-minute run/walk EFT for estimating CRF ([Formula: see text] and 2 the accuracy of HRR measured after an EFT using a heart rate monitor (HRM in an asymptomatic population. METHODS: Fifty subjects (48% women ages 18-45 years completed a symptom-limited exercise tolerance test (ETT (Bruce protocol and an EFT on separate days. During the ETT, [Formula: see text] was measured by a metabolic cart, and heart rate was measured continuously by a HRM and a metabolic cart. RESULTS: EFT distance and sex independently predicted[Formula: see text]. The average absolute difference between observed and predicted [Formula: see text] was 0.26 ± 3.27 ml·kg-1·min-1 for our model compared to 7.55 ± 3.64 ml·kg-1·min-1 for the Cooper model. HRM HRR data were equivalent to respective metabolic cart values during the ETT. HRR at 1 minute post-exercise during ETT compared to the EFT had a moderate correlation (r=0.75, p<0.001. CONCLUSION: A more accurate model to estimate CRF from a 12-minute run/walk EFT was developed, and HRR can be measured using a HRM in an asymptomatic population outside of clinical settings.

  7. High Efficiency Water Heating Technology Development Final Report. Part I, Lab/Field Performance Evaluation and Accelerated Life Testing of a Hybrid Electric Heat Pump Water Heater (HPWH)

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Murphy, Richard W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linkous, Randall Lee [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-04-01

    DOE has supported efforts for many years with the objective of getting a water heater that uses heat pump technology (aka a heat pump water heater or HPWH) successfully on the residential equipment market. The most recent previous effort (1999-2002) produced a product that performed very well in ORNL-led accelerated durability and field tests. The commercial partner for this effort, Enviromaster International (EMI), introduced the product to the market under the trade name Watter$aver in 2002 but ceased production in 2005 due to low sales. A combination of high sales price and lack of any significant infrastructure for service after the sale were the principal reasons for the failure of this effort. What was needed for market success was a commercial partner with the manufacturing and market distribution capability necessary to allow economies of scale to lead to a viable unit price together with a strong customer service infrastructure. General Electric certainly meets these requirements, and knowing of ORNL s expertise in this area, approached ORNL with the proposal to partner in a CRADA to produce a high efficiency electric water heater. A CRADA with GE was initiated early in Fiscal Year, 2008. GE initially named its product the Hybrid Electric Water Heater (HEWH).

  8. Development of a Pediatric Visual Field Test.

    Science.gov (United States)

    Miranda, Marco A; Henson, David B; Fenerty, Cecilia; Biswas, Susmito; Aslam, Tariq

    2016-12-01

    We describe a pediatric visual field (VF) test based on a computer game where software and hardware combine to provide an enjoyable test experience. The test software consists of a platform-based computer game presented to the central VF. A storyline was created around the game as was a structure surrounding the computer monitor to enhance patients' experience. The patient is asked to help the central character collect magic coins (stimuli). To collect these coins a series of obstacles need to be overcome. The test was presented on a Sony PVM-2541A monitor calibrated from a central midpoint with a Minolta CS-100 photometer placed at 50 cm. Measurements were performed at 15 locations on the screen and the contrast calculated. Retinal sensitivity was determined by modulating stimulus in size. To test the feasibility of the novel approach 20 patients (4-16 years old) with no history of VF defects were recruited. For the 14 subjects completing the study, 31 ± 15 data points were collected on 1 eye of each patient. Mean background luminance and stimulus contrast were 9.9 ± 0.3 cd/m(2) and 27.9 ± 0.1 dB, respectively. Sensitivity values obtained were similar to an adult population but variability was considerably higher - 8.3 ± 9.0 dB. Preliminary data show the feasibility of a game-based VF test for pediatric use. Although the test was well accepted by the target population, test variability remained very high. Traditional VF tests are not well tolerated by children. This study describes a child-friendly approach to test visual fields in the targeted population.

  9. Test and Evaluation of Autonomous Ground Vehicles

    OpenAIRE

    Yang Sun; Guangming Xiong; Weilong Song; Jianwei Gong; Huiyan Chen

    2014-01-01

    A preestablished test and evaluation system will benefit the development of autonomous ground vehicles. This paper proposes a design method for a scientific and comprehensive test and evaluation system for autonomous ground vehicles competitions. It can better guide and regulate the development of China’s autonomous ground vehicles. The test and evaluation system includes the test contents, the test environment, the test methods, and the evaluation methods. Using a hierarchical design approac...

  10. Field Test Kit for Gun Residue Detection

    Energy Technology Data Exchange (ETDEWEB)

    WALKER, PAMELA K.; RODACY, PHILIP J.

    2002-01-01

    One of the major needs of the law enforcement field is a product that quickly, accurately, and inexpensively identifies whether a person has recently fired a gun--even if the suspect has attempted to wash the traces of gunpowder off. The Field Test Kit for Gunshot Residue Identification based on Sandia National Laboratories technology works with a wide variety of handguns and other weaponry using gunpowder. There are several organic chemicals in small arms propellants such as nitrocellulose, nitroglycerine, dinitrotoluene, and nitrites left behind after the firing of a gun that result from the incomplete combustion of the gunpowder. Sandia has developed a colorimetric shooter identification kit for in situ detection of gunshot residue (GSR) from a suspect. The test kit is the first of its kind and is small, inexpensive, and easily transported by individual law enforcement personnel requiring minimal training for effective use. It will provide immediate information identifying gunshot residue.

  11. Ice slurry cooling development and field testing

    Energy Technology Data Exchange (ETDEWEB)

    Kasza, K.E. [Argonne National Lab., IL (United States); Hietala, J. [Northern States Power Co., Minneapolis, MN (United States); Wendland, R.D. [Electric Power Research Inst., Palo Alto, CA (United States); Collins, F. [USDOE, Washington, DC (United States)

    1992-07-01

    A new advanced cooling technology collaborative program is underway involving Argonne National Laboratory (ANL), Northern States Power (NSP) and the Electric Power Research Institute (EPRI). The program will conduct field tests of an ice slurry distributed load network cooling concept at a Northern States Power utility service center to further develop and prove the technology and to facilitate technology transfer to the private sector. The program will further develop at Argonne National Laboratory through laboratory research key components of hardware needed in the field testing and develop an engineering data base needed to support the implementation of the technology. This program will sharply focus and culminate research and development funded by both the US Department of Energy and the Electric Power Research Institute on advanced cooling and load management technology over the last several years.

  12. Ice slurry cooling development and field testing

    Energy Technology Data Exchange (ETDEWEB)

    Kasza, K.E. (Argonne National Lab., IL (United States)); Hietala, J. (Northern States Power Co., Minneapolis, MN (United States)); Wendland, R.D. (Electric Power Research Inst., Palo Alto, CA (United States)); Collins, F. (USDOE, Washington, DC (United States))

    1992-01-01

    A new advanced cooling technology collaborative program is underway involving Argonne National Laboratory (ANL), Northern States Power (NSP) and the Electric Power Research Institute (EPRI). The program will conduct field tests of an ice slurry distributed load network cooling concept at a Northern States Power utility service center to further develop and prove the technology and to facilitate technology transfer to the private sector. The program will further develop at Argonne National Laboratory through laboratory research key components of hardware needed in the field testing and develop an engineering data base needed to support the implementation of the technology. This program will sharply focus and culminate research and development funded by both the US Department of Energy and the Electric Power Research Institute on advanced cooling and load management technology over the last several years.

  13. New Rapid Evaluation for Long-Term Behavior in Deep Geological Repository by Geotechnical Centrifuge. Part 1: Test of Physical Modeling in Near Field Under Isotropic Stress-Constraint Conditions

    Science.gov (United States)

    Nishimoto, Soshi; Sawada, Masataka; Okada, Tetsuji

    2016-08-01

    The objective of this study is to evaluate the long-term geomechanical behavior of a geological repository for high-level radioactive waste disposal, using the centrifugal near-field model test. The model consisted of a sedimentary rock mass, bentonite buffer, and model overpack, and was enclosed within a pressure vessel. Tests were conducted with a centrifugal force field of 30 G under isotropic stress-constraint conditions with confining pressures of 5-10 MPa and injection of pore water up through a time period equivalent to about 165 years in the field. Our results showed that the measured values and the temporal changes in the displacement of the overpack, the soil pressure of the bentonite, and the strain of the rock mass were clearly dependent on the confining pressure. These data were not convergent during the test. Our data experimentally revealed that long-term behavior in the near field was changed by the geomechanical interaction between the deformation stress of the bedrock/disposal hole and the swelling behavior of the bentonite buffer.

  14. Combustion Safety Simplified Test Protocol Field Study

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L [Gas Technology Inst., Des Plaines, IL (United States); Cautley, D. [Gas Technology Inst., Des Plaines, IL (United States); Bohac, D. [Gas Technology Inst., Des Plaines, IL (United States); Francisco, P. [Gas Technology Inst., Des Plaines, IL (United States); Shen, L. [Gas Technology Inst., Des Plaines, IL (United States); Gloss, S. [Gas Technology Inst., Des Plaines, IL (United States)

    2015-11-05

    "9Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.

  15. Field-based physiological testing of wheelchair athletes.

    Science.gov (United States)

    Goosey-Tolfrey, Victoria L; Leicht, Christof A

    2013-02-01

    The volume of literature on field-based physiological testing of wheelchair sports, such as basketball, rugby and tennis, is considerably smaller when compared with that available for individuals and team athletes in able-bodied (AB) sports. In analogy to the AB literature, it is recognized that performance in wheelchair sports not only relies on fitness, but also sport-specific skills, experience and technical proficiency. However, in contrast to AB sports, two major components contribute towards 'wheeled sports' performance, which are the athlete and the wheelchair. It is the interaction of these two that enable wheelchair propulsion and the sporting movements required within a given sport. Like any other athlete, participants of wheelchair sports are looking for efficient ways to train and/or analyse their technique and fitness to improve their performance. Consequently, laboratory and/or field-based physiological monitoring tools used at regular intervals at key time points throughout the year must be considered to help with training evaluation. The present review examines methods available in the literature to assess wheelchair sports fitness in a field-based environment, with special attention on outcome variables, validity and reliability issues, and non-physiological influences on performance. It also lays out the context of field-based testing by providing details about the Paralympic court sports and the impacts of a disability on sporting performance. Due to the limited availability of specialized equipment for testing wheelchair-dependent participants in the laboratory, the adoption of field-based testing has become the preferred option by team coaches of wheelchair athletes. An obvious advantage of field-based testing is that large groups of athletes can be tested in less time. Furthermore, athletes are tested in their natural environment (using their normal sports wheelchair set-up and floor surface), potentially making the results of such testing

  16. Field Evaluation of Programmable Thermostats

    Energy Technology Data Exchange (ETDEWEB)

    Sachs, O.; Tiefenbeck, V.; Duvier, C.; Qin, A.; Cheney, K.; Akers, C.; Roth, K.

    2012-12-01

    Prior research suggests that poor programmable thermostats usability may prevent their effective use to save energy. We hypothesized that home occupants with a high-usability thermostats would be more likely to use them to save energy than people with a basic thermostat. We randomly installed a high-usability thermostat in half the 77 apartments of an affordable housing complex, installing a basic thermostat in the other half. During the heating season, we collected space temperature and furnace on-off data to evaluate occupant interaction with the thermostats, foremost nighttime setbacks. We found that thermostat usability did not influence energy-saving behaviors, finding no significant difference in temperature maintained among apartments with high- and low-usability thermostats.

  17. A new method of field MRTD test

    Science.gov (United States)

    Chen, Zhibin; Song, Yan; Liu, Xianhong; Xiao, Wenjian

    2014-09-01

    MRTD is an important indicator to measure the imaging performance of infrared camera. In the traditional laboratory test, blackbody is used as simulated heat source which is not only expensive and bulky but also difficult to meet field testing requirements of online automatic infrared camera MRTD. To solve this problem, this paper introduces a new detection device for MRTD, which uses LED as a simulation heat source and branded plated zinc sulfide glass carved four-bar target as a simulation target. By using high temperature adaptability cassegrain collimation system, the target is simulated to be distance-infinite so that it can be observed by the human eyes to complete the subjective test, or collected to complete objective measurement by image processing. This method will use LED to replace blackbody. The color temperature of LED is calibrated by thermal imager, thereby, the relation curve between the LED temperature controlling current and the blackbody simulation temperature difference is established, accurately achieved the temperature control of the infrared target. Experimental results show that the accuracy of the device in field testing of thermal imager MRTD can be limited within 0.1K, which greatly reduces the cost to meet the project requirements with a wide application value.

  18. Performance Test of CCTV in a Test Field

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyung Min [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2011-10-15

    On April 12-13, 2010, US President Obama hosted a Nuclear Security Summit in Washington, DC, to enhance international cooperation to prevent nuclear terrorism, an issue which he has identified as the most immediate and extreme threat to global security. The Summit focused on the security of nuclear materials, nonproliferation, disarmament, and peaceful nuclear energy. At the summit, the Republic of Korea was chosen as the host of the next Summit in 2012. This series of events reflects the growing global interest on 'Nuclear Security' and as the host country of the next Nuclear Summit it is the time for Korea to strengthen the physical protection regime for nuclear facilities as a first step of securing its nuclear security capability. KINAC has been operating Test field as a mean of preparing solid backup data for reviewing and revising DBT (Design Basis Threat) and to test components of the conventional physical protection system. CCTV is a key component which is used worldwide for the assessment measure of alarms. In terms of performance test of CCTV, there are several elements such as image quality, coverage and mechanical features (speed of zoom-in-out, capture, angle shift etc.). Speaking of image quality acquired by the CCTV, the quality is subject to resolution, monitor specification, camera housing, camera mounting and lightening. Thus it is clear that performance tests on image quality should consider those factors and vary the factors respectively in order to verify the influence and the interaction among those. Nevertheless due to the restrictions of the current Test field, this paper focuses on the image quality through resolution test under the various lightening conditions

  19. Evaluation of field dental equipment in a deployment environment.

    Science.gov (United States)

    Charlton, David G; Ehrlich, A Dale; Ragain, James C; Lyles, Mark B; Roberts, Howard W

    2006-03-01

    Dental officers and technicians must have reliable, durable, well-performing field dental equipment to enable them to provide dental care to deployed troops in operational environments. Unfortunately, no organized program exists to test such equipment before its purchase and use in the field. This article presents the results of a project conducted by the Naval Institute for Dental and Biomedical Research and the Air Force Dental Evaluation and Consultation Service to evaluate commercially available field dental equipment through laboratory testing and clinical-user evaluations in theater. The purpose of this 2-year project was to identify the best-performing and most cost-effective field dental equipment for possible future procurement. Initial laboratory testing was performed at the Naval Institute for Dental and Biomedical Research, and the equipment was then shipped to Kuwait for in-theater environmental and clinical-user testing. A seven-member scientific team of military dental officers and technicians was deployed for 1 month to perform in-theater testing under regional environmental conditions and to coordinate clinical-user evaluations. The testing provided beneficial results by identifying equipment that performed properly and equipment that exhibited shortcomings serious enough to render it inadequate for operational use. It is recommended that the project serve as a model for future testing and evaluation of medical/dental equipment by all of the military services.

  20. Performance analysis in Japanese field test program; Field test data kara no chiiki hatsuden kaiseki hoho

    Energy Technology Data Exchange (ETDEWEB)

    Sugiyama, H.; Kurokawa, K.; Uchida, D. [Tokyo University of Agriculture and Technology, Tokyo (Japan); Otani, K.; Sakuta, K.; Tsuda, I. [Electrotechnical Laboratory, Tsukuba (Japan); Oshiro, T.; Sakamoto, K. [Japan Quality Assurance Organization, Tokyo (Japan)

    1997-11-25

    Power generation characteristics are investigated using data collected in photovoltaic power generation field tests being undertaken by NEDO (New Energy and Industrial Technology Development Organization). The photovoltaic power generation system performance is evaluated by examining loss factors leading to degradation in system performance, with weather conditions such as variation in insolation and air temperature, inverter performance, and shadows cast by surrounding buildings taken into consideration. As the result, it is found that the important loss factors are degradation in module performance due to elevated temperature, drift in the maximum output control, degraded inverter performance due to input power variation, effect of shadows, etc. It is learned that system is greatly affected by degradation in module performance due to increased temperature in summer and by shadows in winter, the two being responsible for the output coefficient dropping to approximately 75% throughout the year. The output coefficient frequency distribution charts for the 75 test sites confirm that the rate is as low as 70-80% at many sites. As for the system operating time, it tends to be longer in West Japan where the annual insolation rate is higher. 3 refs., 10 figs.

  1. The Evaluator Effect in Usability Tests

    DEFF Research Database (Denmark)

    Jacobsen, Niels Ebbe; Hertzum, Morten; John, Bonnie E.

    1998-01-01

    Usability tests are applied in industry to evaluate systems and in research as a yardstick for other usability evaluation methods. However, one potential threat to the reliability of usability tests has been left unaddressed: the evaluator effect. In this study, four evaluators analyzed four...... videotaped usability test sessions. Only 20% of the 93 unique problems were detected by all four evaluators and 46% were detected by only a single evaluator. Severe problems were detected more often by all four evaluators (41%) and less often by only one evaluator (22%) but a substantial evaluator effect...

  2. Field evaluation of Abbott Real Time HIV-1 Qualitative test for early infant diagnosis using dried blood spots samples in comparison to Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Qual test in Kenya.

    Science.gov (United States)

    Chang, Joy; Omuomo, Kenneth; Anyango, Emily; Kingwara, Leonard; Basiye, Frank; Morwabe, Alex; Shanmugam, Vedapuri; Nguyen, Shon; Sabatier, Jennifer; Zeh, Clement; Ellenberger, Dennis

    2014-08-01

    Timely diagnosis and treatment of infants infected with HIV are critical for reducing infant mortality. High-throughput automated diagnostic tests like Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 Qual Test (Roche CAPCTM Qual) and the Abbott Real Time HIV-1 Qualitative (Abbott Qualitative) can be used to rapidly expand early infant diagnosis testing services. In this study, the performance characteristics of the Abbott Qualitative were evaluated using two hundred dried blood spots (DBS) samples (100 HIV-1 positive and 100 HIV-1 negative) collected from infants attending the antenatal facilities in Kisumu, Kenya. The Abbott Qualitative results were compared to the diagnostic testing completed using the Roche CAPCTM Qual in Kenya. The sensitivity and specificity of the Abbott Qualitative were 99.0% (95% CI: 95.0-100.0) and 100.0% (95% CI: 96.0-100.0), respectively, and the overall reproducibility was 98.0% (95% CI: 86.0-100.0). The limits of detection for the Abbott Qualitative and Roche CAPCTM Qual were 56.5 and 6.9copies/mL at 95% CIs (p=0.005), respectively. The study findings demonstrate that the Abbott Qualitative test is a practical option for timely diagnosis of HIV in infants.

  3. Preliminary Results of Field Emission Cathode Tests

    Science.gov (United States)

    Sovey, James S.; Kovaleski, Scott D.

    2001-01-01

    Preliminary screening tests of field emission cathodes such as chemical vapor deposited (CVD) diamond, textured pyrolytic graphite, and textured copper were conducted at background pressures typical of electric thruster test facilities to assess cathode performance and stability. Very low power electric thrusters which provide tens to hundreds micronewtons of thrust may need field emission neutralizers that have a capability of tens to hundreds of microamperes. From current voltage characteristics, it was found that the CVD diamond and textured metals cathodes clearly satisfied the Fowler-Nordheim emission relation. The CVD diamond and a textured copper cathode had average current densities of 270 and 380 mA/sq cm, respectively, at the beginning-of-life. After a few hours of operation the cathode emission currents degraded by 40 to 75% at background pressures in the 10(exp -5) Pa to 10(exp -4) Pa range. The textured pyrolytic graphite had a modest current density at beginning-of-life of 84 mA/sq cm, but this cathode was the most stable of all. Extended testing of the most promising cathodes is warranted to determine if current degradation is a burn-in effect or whether it is a long-term degradation process. Preliminary experiments with ferroelectric emission cathodes, which are ceramics with spontaneous electric polarization, were conducted. Peak current densities of 30 to 120 mA/sq cm were obtained for pulse durations of about 500 ns in the 10(exp -4) Pa pressure range.

  4. Field-Based Video Pre-Test Counseling, Oral Testing, and Telephonic Post-Test Counseling: Implementation of an HIV Field Testing Package among High-Risk Indian Men

    Science.gov (United States)

    Snyder, Hannah; Yeldandi, Vijay V.; Kumar, G. Prem; Liao, Chuanhong; Lakshmi, Vemu; Gandham, Sabitha R.; Muppudi, Uma; Oruganti, Ganesh; Schneider, John A.

    2012-01-01

    In India, men who have sex with men (MSM) and truck drivers are high-risk groups that often do not access HIV testing due to stigma and high mobility. This study evaluated a field testing package (FTP) that identified HIV positive participants through video pre-test counseling, OraQuick oral fluid HIV testing, and telephonic post-test counseling…

  5. An Evaluation of the CAI (Computer Assisted Instruction) Segments of the Tow Field Test Set and the Hawk CW (Continuous Wave) Radar Repair Courses.

    Science.gov (United States)

    1983-06-29

    cuantitative , oojec- tive way by calculating hardware reliability factors such as mean time between failure and also by subjective estimates of the...schedule. The manufacturer has a different model than used in this test (equivalent, but newer) on the GSA schedule at $6,780. The manufacturer has the...exact model used in this test available, only at retail, for S7,450. In our calculations, the $6,780 figure was used. For TFTS the calculation for

  6. Evaluative Practices in the Culinary Field

    DEFF Research Database (Denmark)

    Christensen, Bo; Strandgaard, Jesper

    This paper is concerned with evaluative practices within the culinary field. The focus is on the evaluative practices performed by two restaurant ranking systems, respectively the Michelin Red Guide system handled by the French tire manufacturer Michelin and the San Pellegrino ’World’s 50 Best...

  7. Evaluation of Cold Tolerance in Field Grown Mentha (Mentha piperita‎‏ L.)‎ under ‎Laboratory Conditions by Electrolyte Leakage Test

    OpenAIRE

    T Kheirkhah; A Nezami; M Kafi; Gh. A. Asadi

    2015-01-01

    In order to determine cold tolerance of field grown Mentha (Mentha Piperita L.) under controlled conditions, using electrolyte leakage index, an experiment was carried out at the College of Agriculture, Ferdowsi University of Mashhad, based on a completely randomized design with four replications. Experimental factors included six freezing temperatures (Zero, -4, -8, -12, -16 and -20 °C), seven harvest ‎time (November, December, January, February, March, April and May) and ‎four Peppermint or...

  8. Yucca Mountain site characterization: The field testing program

    Energy Technology Data Exchange (ETDEWEB)

    Williams, D.R.; Matthusen, A.C.

    1994-12-31

    The Yucca Mountain area was first considered as a site for possible characterization as a high level waste repository in 1977. Since that time preliminary field testing and Congressional directive recommended continued testing and determined in 1987 that Yucca Mountain would be the only site characterized. Following environmental assessment, the development of a site characterization plan, and litigation with the State of Nevada testing from both surface-based perspective and underground in the Exploratory Studies Facility is underway. Data and analyses from the comprehensive testing program will be evaluated on a periodic basis of two year cycles to provide direction to the testing program. The entire testing program will culminate in a determination of site suitability near the end of the twentieth century.

  9. FIELD TEST OF THE FLAME QUALITY INDICATOR

    Energy Technology Data Exchange (ETDEWEB)

    Rudin, Andrew M; Butcher, Thomas; Troost, Henry

    2003-02-04

    The flame quality indicator concept was developed at BNL specifically to monitor the brightness of the flame in a small oil burner and to provide a ''call for service'' notification when the brightness has changed from its setpoint, either high or low. In prior development work BNL has explored the response of this system to operational upsets such as excess air changes, fouled atomizer nozzles, poor fuel quality, etc. Insight Technologies, Inc. and Honeywell, Inc. have licensed this technology from the U.S. Department of Energy and have been cooperating to develop product offerings which meet industry needs with an optimal combination of function and price. Honeywell has recently completed the development of the Flame Quality Monitor (FQM or Honeywell QS7100F). This is a small module which connects via a serial cable to the burners primary operating control. Primary advantages of this approach are simplicity, cost, and ease of installation. Call-for-service conditions are output in the form of front panel indicator lights and contact closure which can trigger a range of external communication options. Under this project a field test was conducted of the FQM in cooperation with service organizations in Virginia, Pennsylvania, New Jersey, New York, and Connecticut. At total of 83 field sites were included. At each site the FQM was installed in parallel with another embodiment of this concept--the Insight AFQI. The AFQI incorporates a modem and provides the ability to provide detailed information on the trends in the flame quality over the course of the two year test period. The test site population was comprised of 79.5% boilers, 13.7% warm air furnaces, and 6.8% water heaters. Nearly all were of residential size--with firing rates ranging from 0.6 gallons of oil per hour to 1.25. During the course of the test program the monitoring equipment successfully identified problems including: plugged fuel lines, fouled nozzles, collapsed combustion

  10. Cooperative field test program for wind systems

    Energy Technology Data Exchange (ETDEWEB)

    Bollmeier, W.S. II; Dodge, D.M.

    1992-03-01

    The objectives of the Federal Wind Energy Program, managed by the US Department of Energy (DOE), are (1) to assist industry and utilities in achieving a multi-regional US market penetration of wind systems, and (2) to establish the United States as the world leader in the development of advanced wind turbine technology. In 1984, the program conducted a series of planning workshops with representatives from the wind energy industry to obtain input on the Five-Year Research Plan then being prepared by DOE. One specific suggestion that came out of these meetings was that the federal program should conduct cooperative research tests with industry to enhance the technology transfer process. It was also felt that the active involvement of industry in DOE-funded research would improve the state of the art of wind turbine technology. DOE established the Cooperative Field Test Program (CFTP) in response to that suggestion. This program was one of the first in DOE to feature joint industry-government research test teams working toward common objectives.

  11. Field project to obtain pressure core, wireline log, and production test data for evaluation of CO/sub 2/ flooding potential. Conoco MCA unit well No. 358, Maljamar Field, Lea County, New Mexico. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Swift, T.E.; Kumar, R.M.; Marlow, R.E.; Wilhelm, M.H.

    1982-08-01

    Field operations, which were conducted as a cooperative effort between Conoco and Gruy Federal, began on January 16, 1980 when the well was spudded. The well was drilled to 3692 feet, and 18 cores recovered in 18 core-barrel runs (144 feet). Upon completion of the coring phase, the hole was drilled to a total depth of 4150 feet and a complete suite of geophysical logs was run. Logging was then followed by completion and testing by Concoco. Core porosities agreed well with computed log porosities. Core water saturation and computed log porosities agree fairly well from 3692 to 3712 feet, poorly from 3712 to 3820 feet and in a general way from 4035 to 4107 feet. Computer log analysis techniques did not improve the agreement of log versus core derived water saturations. However, both core and log analysis indicated the ninth zone had the highest residual hydrocarbon saturations. Residual oil saturation were 259 STB/acre-ft for the 4035 - 4055 feet interval, and 150 STB/acre-ft for the 3692 - 3718 feet interval. Nine BOPD was produced from the 4035 - 4055 feet interval and no oil was produced from 3692 to 3718 feet interval, qualitatively confirming the relative oil saturations. The low oil production in the zone from 4022 to 4055 and the lack of production from 3692 to 3718 feet indicated the zone to be at or near residual waterflood conditions as determined by log analysis. 68 figures, 11 tables.

  12. Evaluation of College English Test

    Institute of Scientific and Technical Information of China (English)

    郭奕奕

    2003-01-01

    There has been much heated discussion on College English Test for non-English majors Band 4 and Band 6 because it has exerted great influence on English teaching in Chinese universities. This essay is intended to explore the reliability, validity,practicality and washback of this large-scale test by focusing on CET Band 4. The author of this report discusses the merits as well as some existing problems of this test and offers some suggestions at the end of the essay.

  13. Test and Evaluation of Autonomous Ground Vehicles

    Directory of Open Access Journals (Sweden)

    Yang Sun

    2014-01-01

    Full Text Available A preestablished test and evaluation system will benefit the development of autonomous ground vehicles. This paper proposes a design method for a scientific and comprehensive test and evaluation system for autonomous ground vehicles competitions. It can better guide and regulate the development of China's autonomous ground vehicles. The test and evaluation system includes the test contents, the test environment, the test methods, and the evaluation methods. Using a hierarchical design approach, the test content is designed to be stage by stage, moving from simplicity to complexity and from individual modules to the entire vehicle. The hierarchical test environment is established according to the levels of test content. The test method based on multilevel platforms and sensors is put forward to ensure the accuracy of test results. A fuzzy comprehensive evaluation method combined with analytic hierarchy process (AHP is used for the comprehensive evaluation which can quantitatively evaluate the individual module and the overall technical performance of autonomous ground vehicles. The proposed test and evaluation system has been successfully applied to real autonomous ground vehicle competitions.

  14. SUPERGLASS. Engineering field tests - Phase 3. Production, market planning, and product evaluation for a high-thermal-performance insulating glass design utilizing HEAT MIRROR transparent insulation. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Tilford, C L

    1982-11-01

    HEAT MIRROR transparent window insulation consists of a clear polyester film two mils (.002'') thick with a thin, clear low-emissivity (.15) coating deposited on one side by state-of-the-art vacuum deposition processes. This neutral-colored invisible coating reflects long-wave infrared energy (heat). When mounted by being stretched with a 1/2'' air-gap on each side of the film, the resulting unit reduces heat loss by 60% compared to dual insulating glass. Southwall Corporation produces HEAT MIRROR transparent insulation and markets it to manufacturers of sealed insulating glass (I.G.) units and window and building manufacturers who make their own I.G. These companies build and sell the SUPERGLASS sealed glazing units. Units made and installed in buildings by six customers were visited. These units were located in many geographic regions, including the Pacific Northwest, Rocky Mountains, New England, Southeast, and West Coast. As much as could be obtained of their history was recorded, as was their current condition and performance. These units had been in place from two weeks to over a year. All of the units were performing thermally very well, as measured by taking temperature profiles through them and through adjacent conventional I.G. units. Some units had minor visual defects (attributed to I.G. assembly techniques) which are discussed in detail. Overall occupant acceptance was enthusiastically positive. In addition to saving energy, without compromise of optical quality or appearance, the product makes rooms with large glazing areas comfortable to be in in cold weather. All defects observed were present when built; there appears to be no in-field degradation of quality at this time.

  15. Field operational tests of Smartway in Japan

    Directory of Open Access Journals (Sweden)

    Fumihiko Kanazawa

    2010-07-01

    Full Text Available Efforts are underway in Japan to promote “Smartway” next-generation roadways, which provide a variety of services through the use of advanced ITS technologies. In recent years, the National Institute for Land and Infrastructure Management (NILIM, part of the Ministry of Land, Infrastructure, Transport and Tourism (MLIT, has conducted public–private joint research on next-generation road services using ITS technologies. Field operational tests (FOTs of services including forward obstacle information provision and merging assistance using 5.8 GHz dedicated short range communication (DSRC were conducted on the Tokyo Metropolitan Expressway through FY2007. In FY2008–2009, FOTs were conducted in three major metropolitan areas—Tokyo, Nagoya, and Keihanshin (Kyoto, Osaka, and Kobe—to promote future deployment nationwide. These included tests of information provision services to alert drivers to forward obstacles hidden beyond the crest of an incline and prevent excessive speed on sharp curves. This paper presents an overview of these FOTs conducted by NILIM in recent years and their results.

  16. Dose-response tests and semi-field evaluation of lethal and sub-lethal effects of slow release pyriproxyfen granules (Sumilarv®0.5G) for the control of the malaria vectors Anopheles gambiae sensu lato.

    Science.gov (United States)

    Mbare, Oscar; Lindsay, Steven W; Fillinger, Ulrike

    2013-03-14

    Recently research has shown that larviciding can be an effective tool for integrated malaria vector control. Nevertheless, the uptake of this intervention has been hampered by the need to re-apply larvicides frequently. There is a need to explore persistent, environmentally friendly larvicides for malaria vector control to reduce intervention efforts and costs by reducing the frequency of application. In this study, the efficacy of a 0.5% pyriproxyfen granule (Surmilarv®0.5G, Sumitomo Chemicals) was assessed for the control of Anopheles gambiae sensu stricto and Anopheles arabiensis, the major malaria vectors in sub-Saharan Africa. Dose-response and standardized field tests were implemented following standard procedures of the World Health Organization's Pesticide Evaluation Scheme to determine: (i) the susceptibility of vectors to this formulation; (ii) the residual activity and appropriate retreatment schedule for field application; and, (iii) sub-lethal impacts on the number and viability of eggs laid by adults after exposure to Sumilarv®0.5G during larval development. Anopheles gambiae s.s. and An. arabiensis were highly susceptible to Sumilarv®0.5G. Estimated emergence inhibition (EI) values were very low and similar for both species. The minimum dosage that completely inhibited adult emergence was between 0.01-0.03 parts per million (ppm) active ingredient (ai). Compared to the untreated control, an application of 0.018 ppm ai prevented 85% (95% confidence interval (CI) 82%-88%) of adult emergence over six weeks under standardized field conditions. A fivefold increase in dosage of 0.09 ppm ai prevented 97% (95% CI 94%-98%) emergence. Significant sub-lethal effects were observed in the standardized field tests. Female An. gambiae s.s. that were exposed to 0.018 ppm ai as larvae laid 47% less eggs, and females exposed to 0.09 ppm ai laid 74% less eggs than females that were unexposed to the treatment. Furthermore, 77% of eggs laid by females exposed to 0

  17. Evaluation of near-field earthquake effects

    Energy Technology Data Exchange (ETDEWEB)

    Shrivastava, H.P.

    1994-11-01

    Structures and equipment, which are qualified for the design basis earthquake (DBE) and have anchorage designed for the DBE loading, do not require an evaluation of the near-field earthquake (NFE) effects. However, safety class 1 acceleration sensitive equipment such as electrical relays must be evaluated for both NFE and DBE since they are known to malfunction when excited by high frequency seismic motions.

  18. Aircraft Test & Evaluation Facility (Hush House)

    Data.gov (United States)

    Federal Laboratory Consortium — The Aircraft Test and Evaluation Facility (ATEF), or Hush House, is a noise-abated ground test sub-facility. The facility's controlled environment provides 24-hour...

  19. Top Zika Vaccine Candidate Moves Closer to Field Testing

    Science.gov (United States)

    ... https://medlineplus.gov/news/fullstory_161274.html Top Zika Vaccine Candidate Moves Closer to Field Testing DNA- ... MONDAY, Oct. 3, 2016 (HealthDay News) -- The leading Zika vaccine candidate should be ready for field testing ...

  20. SMART wind turbine rotor. Design and field test

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Jonathan Charles; Resor, Brian Ray; Paquette, Joshua A.; White, Jonathan Randall

    2014-01-01

    The Wind Energy Technologies department at Sandia National Laboratories has developed and field tested a wind turbine rotor with integrated trailing-edge flaps designed for active control of rotor aerodynamics. The SMART Rotor project was funded by the Wind and Water Power Technologies Office of the U.S. Department of Energy (DOE) and was conducted to demonstrate active rotor control and evaluate simulation tools available for active control research. This report documents the design, fabrication, and testing of the SMART Rotor. This report begins with an overview of active control research at Sandia and the objectives of this project. The SMART blade, based on the DOE / SNL 9-meter CX-100 blade design, is then documented including all modifications necessary to integrate the trailing edge flaps, sensors incorporated into the system, and the fabrication processes that were utilized. Finally the test site and test campaign are described.

  1. Field Testing of Environmentally Friendly Drilling System

    Energy Technology Data Exchange (ETDEWEB)

    David Burnett

    2009-05-31

    The Environmentally Friendly Drilling (EFD) program addresses new low-impact technology that reduces the footprint of drilling activities, integrates light weight drilling rigs with reduced emission engine packages, addresses on-site waste management, optimizes the systems to fit the needs of a specific development sites and provides stewardship of the environment. In addition, the program includes industry, the public, environmental organizations, and elected officials in a collaboration that addresses concerns on development of unconventional natural gas resources in environmentally sensitive areas. The EFD program provides the fundamentals to result in greater access, reasonable regulatory controls, lower development cost and reduction of the environmental footprint associated with operations for unconventional natural gas. Industry Sponsors have supported the program with significant financial and technical support. This final report compendium is organized into segments corresponding directly with the DOE approved scope of work for the term 2005-2009 (10 Sections). Each specific project is defined by (a) its goals, (b) its deliverable, and (c) its future direction. A web site has been established that contains all of these detailed engineering reports produced with their efforts. The goals of the project are to (1) identify critical enabling technologies for a prototype low-impact drilling system, (2) test the prototype systems in field laboratories, and (3) demonstrate the advanced technology to show how these practices would benefit the environment.

  2. Field Test Results on Natural Field IP Method

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    In this paper the authors propose the natural field induced polarization (IP) method and present the way to pick up IP effect. The relations between the object and anomaly are studied by taking field experiments as examples. The effectiveness and usability of the method are testified.

  3. Development of an Evaluation System for Vertical Vibration of Railway Vehicles with Field-Portable Actuators (1st Report, Data Processing Method to Estimate Running-Vehicle Vibration from Stationary Vibration Test)

    Science.gov (United States)

    Tomioka, Takahiro; Takigami, Tadao

    The authors are developing a vibration evaluation system, which consists of field-portable exciters (actuators) and data processing software, to estimate vertical vibration and ride quality of railway vehicles. One of the main characteristics of the system is that the acceleration power spectral density (PSD) at arbitrary point on the carbody in running condition is synthesized numerically from measured data obtained when each axle box or each wheelset is excited individually using limited number of actuators. This paper focuses upon the data processing method for the vibration evaluation system. A series of excitation tests for a commuter vehicle is carried out to confirm the basic concept to estimate the PSD by using the rolling stock testing plant at Railway Technical Research Institute. Some excitation methodologies and data processing formulae are compared among each other. It is clearly shown that the estimated PSDs well agree with actual PSD. It is found out that the estimation gives high accurate results when only excited axle box acceleration are used in estimation analysis.

  4. Intermittent versus Continuous Incremental Field Tests: Are Maximal Variables Interchangeable?

    Science.gov (United States)

    Carminatti, Lorival J; Possamai, Carlos A P; de Moraes, Marcelo; da Silva, Juliano F; de Lucas, Ricardo D; Dittrich, Naiandra; Guglielmo, Luiz G A

    2013-01-01

    The aim of the present study was to compare physiological responses derived from an incremental progressive field test with a constant speed test i.e. intermittent versus continuous protocol. Two progressive maximum tests (Carminatti`s test (T-CAR) and the Vameval test (T-VAM)), characterized by increasing speed were used. T-CAR is an intermittent incremental test, performed as shuttle runs; while T-VAM is a continuous incremental test performed on an athletic track. Eighteen physically active, healthy young subjects (21.9 ± 2.0 years; 76.5 ± 8.6 kg, 1.78 ± 0.08 m, 11.2 ± 5.4% body fat), volunteered for this study. Subjects performed four different maximum test sessions conducted in the field: two incremental tests and two time to exhaustion tests (TTE) at peak test velocities (PV). No significant differences were found for PV (T-CAR = 15.6 ± 1.2; T-VAM = 15.5 ± 1.3 km·h(-1)) and maximal HR (T-CAR = 195 ± 11; T- VAM = 194 ± 14 bpm). During TTE, there were no significant differences for HR (TTET-CAR and TTET-VAM = 192 ± 12 bpm). However, there was a significant difference in TTE (p = 0.04) (TTET-CAR = 379 ± 84, TTET-VAM = 338 ± 58 s) with a low correlation (r = 0.41). The blood lactate concentration measured at the end of the TTE tests, showed no significant difference (TTET-CAR = 13.2 ± 2.4 vs. TTET-VAM = 12.9 ± 2.4 mmol·l(-1)). Based on the present findings, it is suggested that the maximal variables derived from T-CAR and T-VAM can be interchangeable in the design of training programs. Key pointsT-CAR is an intermittent shuttle run test that predicts the maximal aerobic speed with accuracy, hence, test results could be interchangeable with continuous straight-line tests.T-CAR provides valid field data for evaluating aerobic fitness.In comparison with T-VAM, T-CAR may be a more favourable way to prescribe intermittent training using a shuttle-running protocol.

  5. Prototype Engineered Barrier System Field Test (PEBSFT); Final report

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, A.L. [ed.; Buscheck, T.; Carlson, R.; Daily, W.; Lee, K.; Lin, Wunan; Mao, Nai-hsien; Ueng, Tzou-Shin; Wang, H.; Watwood, D.

    1991-08-01

    This final report represents a summary of data and interpretations obtained from the Prototype Engineered Barrier System Field Test (PEBSFT) performed in G-Tunnel within the Nevada Test Site. The PEBSFT was conducted to evaluate the applicability of measurement techniques, numerical models, and procedures developed for future field tests that will be conducted in the Exploratory Studies Facilities (ESF) at Yucca Mountain. The primary objective of the test was to provide a basis for determining whether tests planned for the ESF have the potential to be successful. Chapter 1 on high frequency electromagnetic tomography discusses the rock mass electromagnetic permittivity and attenuation rate changes that were measured to characterize the water distribution in the near field of a simulated waste container. The data are used to obtain quantitative estimates of how the moisture content in the rock mass changes during heating and to infer properties of the spatial variability of water distribution, leading to conclusions about the role of fractures in the system. Chapter 2 discusses the changes in rock moisture content detected by the neutron logging probe. Chapter 3 permeability tests discusses the characterization of the in-situ permeability of the fractured tuff around the borehole. The air permeability testing apparatus, the testing procedures, and the data analysis are presented. Chapter 4 describes the moisture collection system installed in the heater borehole to trap and measure the moisture volumes. Chapter 5 describes relative humidity measurements made with the thermocouple psychrometer and capacitance sensors. Chapter 6 discusses gas pressure measurements in the G-Tunnel, addressing the calibration and installation of piezoresistive-gaged transducers. Chapter 7 describes the calibration and installation of thermocouples for temperature measurements. Chapter 8 discusses the results of the PEBSFT.

  6. FY 1998 evaluation/analysis by site of the data collected in the field test project for photovoltaic power generation for public facilities. 2/4; 1998 nendo kokyo shisetsu nadoyo taiyoko hatsuden field test jigyo ni okeru shushu data hyoka kaiseki kaku site betsu 2/4

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    The data collected monthly in the FY 1998 photovoltaic power generation field test project for public facilities were evaluated/analyzed by site. The data items are the flux of global solar radiation/global radiation on an inclined surface/effective global radiation on an inclined surface (each: kWh/m{sup 2}), mean temperature, and array electric energy/system consumption power/load electric energy/system supply load/back flow electric energy (each: kWh). Others are times of linkage protection movement, linkage disconnection time (min), system operation time (min), independent supply load (kWh), equivalent array/equivalent system operation time, array/system output coefficient, system utilization rate/power generation efficiency, INV effective efficiency, and INV load factor. The sites for survey are school (junior and senior high school/elementary school/kindergarten/nursery), lifelong education facilities (technical training center/forestry study center), government office (government office building), environmental public facilities (water purification plant/disaster-prevention center/park), welfare facilities (special nursing care center for the elderly), public facilities (community center/martial arts center), cultural facilities, factory in area, etc. (NEDO)

  7. Field assessments in conjunction with whole effluent toxicity testing

    Energy Technology Data Exchange (ETDEWEB)

    La Point, T.W.; Waller, W.T.

    2000-01-01

    Whole effluent toxicity (WET) tests are widely used to assess potential effects of wastewater discharges on aquatic life. This paper represents a summary of chapters in a 1996 Society of Environmental Toxicology and Chemistry-sponsored workshop and a literature review concerning linkages between WET testing and associated field biomonitoring. Most published studies thus far focus primarily on benthic macroinvertebrates and on effluent-dominated stream systems in which effluents demonstrate little or no significant acute toxicity. Fewer studies examine WET test predictability in other aquatic ecosystems (e.g., wetlands, estuaries, large rivers) or deal with instream biota such as fish and primary producers. Published results indicate that standards for the usual WET freshwater test species, Ceriodaphnia dubia and Pimephales promelas, may not always protect most of the species inhabiting a receiving stream. Although WET tests are useful in predicting aquatic individual responses, they are not meant to directly measure natural population or community responses. Further, they do not address bioconcentration or bioaccumulation of hydrophobic compounds; do not assess eutrophication effects in receiving systems; and lastly, do not reflect genotoxic effects or function to test for endocrine-disrupting chemicals. Consequently, a more direct evaluation of ecosystem health, using bioassessment techniques, may be needed to properly evaluate aquatic systems affected by wastewater discharges.

  8. [Test Reviews in Child Psychology: Test Users Wish to Obtain Practical Information Relevant to their Respective Field of Work].

    Science.gov (United States)

    Renner, Gerolf; Irblich, Dieter

    2016-11-01

    Test Reviews in Child Psychology: Test Users Wish to Obtain Practical Information Relevant to their Respective Field of Work This study investigated to what extent diagnosticians use reviews of psychometric tests for children and adolescents, how they evaluate their quality, and what they expect concerning content. Test users (n = 323) from different areas of work (notably social pediatrics, early intervention, special education, speech and language therapy) rated test reviews as one of the most important sources of information. Readers of test reviews value practically oriented descriptions and evaluations of tests that are relevant to their respective field of work. They expect independent reviews that critically discuss opportunities and limits of the tests under scrutiny. The results show that authors of test reviews should not only have a background in test theory but should also be familiar with the practical application of tests in various settings.

  9. Pre-Clinical Evaluation of a Real-Time PCR Assay on a Portable Instrument as a Possible Field Diagnostic Tool: Experiences from the Testing of Clinical Samples for African and Classical Swine Fever Viruses.

    Science.gov (United States)

    Liu, L; Luo, Y; Accensi, F; Ganges, L; Rodríguez, F; Shan, H; Ståhl, K; Qiu, H-J; Belák, S

    2016-06-16

    African swine fever (ASF) and classical swine fever (CSF) are two highly infectious transboundary animal diseases (TADs) that are serious threats to the pig industry worldwide, including in China, the world's largest pork producer. In this study, a duplex real-time PCR assay was developed for the rapid detection and differentiation of African swine fever virus (ASFV) and classical swine fever virus (CSFV). The assay was performed on a portable, battery-powered PCR thermocycler with a low sample throughput (termed as 'T-COR4 assay'). The feasibility and reliability of the T-COR4 assay as a possible field method was investigated by testing clinical samples collected in China. When evaluated with reference materials or samples from experimental infections, the assay performed in a reliable manner, producing results comparable to those obtained from stationary PCR platforms. Of 59 clinical samples, 41 had results identical to a two-step CSFV real-time PCR assay. No ASFV was detected in these samples. The T-COR4 assay was technically easy to perform and produced results within 3 h, including sample preparation. In combination with a simple sample preparation method, the T-COR4 assay provides a new tool for the field diagnosis and differentiation of ASF and CSF, which could be of particular value in remote areas.

  10. The four-meter confrontation visual field test.

    OpenAIRE

    Kodsi, S R; Younge, B. R.

    1992-01-01

    The 4-m confrontation visual field test has been successfully used at the Mayo Clinic for many years in addition to the standard 0.5-m confrontation visual field test. The 4-m confrontation visual field test is a test of macular function and can identify small central or paracentral scotomas that the examiner may not find when the patient is tested only at 0.5 m. Also, macular sparing in homonymous hemianopias and quadrantanopias may be identified with the 4-m confrontation visual field test....

  11. Test of Nonlocality with an Atom-Field Entangled State

    Institute of Scientific and Technical Information of China (English)

    ZHENG Shi-Biao

    2002-01-01

    We propose a scheme for the test of nonlocality with atom-field entanglement. An atom is sent through a cavity filled with a coherent field with a small amplitude. The dispersive interaction leads to atom-field entanglement.Then the field is driven by a classical current. The Bell inequality can be tested by the joint measurement of the parity of the field and the atomic state.

  12. Field Accuracy Test of Rpas Photogrammetry

    Science.gov (United States)

    Barry, P.; Coakley, R.

    2013-08-01

    Baseline Surveys Ltd is a company which specialises in the supply of accurate geospatial data, such as cadastral, topographic and engineering survey data to commercial and government bodies. Baseline Surveys Ltd invested in aerial drone photogrammetric technology and had a requirement to establish the spatial accuracy of the geographic data derived from our unmanned aerial vehicle (UAV) photogrammetry before marketing our new aerial mapping service. Having supplied the construction industry with survey data for over 20 years, we felt that is was crucial for our clients to clearly understand the accuracy of our photogrammetry so they can safely make informed spatial decisions, within the known accuracy limitations of our data. This information would also inform us on how and where UAV photogrammetry can be utilised. What we wanted to find out was the actual accuracy that can be reliably achieved using a UAV to collect data under field conditions throughout a 2 Ha site. We flew a UAV over the test area in a "lawnmower track" pattern with an 80% front and 80% side overlap; we placed 45 ground markers as check points and surveyed them in using network Real Time Kinematic Global Positioning System (RTK GPS). We specifically designed the ground markers to meet our accuracy needs. We established 10 separate ground markers as control points and inputted these into our photo modelling software, Agisoft PhotoScan. The remaining GPS coordinated check point data were added later in ArcMap to the completed orthomosaic and digital elevation model so we could accurately compare the UAV photogrammetry XYZ data with the RTK GPS XYZ data at highly reliable common points. The accuracy we achieved throughout the 45 check points was 95% reliably within 41 mm horizontally and 68 mm vertically and with an 11.7 mm ground sample distance taken from a flight altitude above ground level of 90 m.The area covered by one image was 70.2 m × 46.4 m, which equals 0.325 Ha. This finding has shown

  13. Monitored Geologic Repository Test Evaluation Plan

    Energy Technology Data Exchange (ETDEWEB)

    M.B. Skorska

    2002-01-02

    The Monitored Geologic Repository test & evaluation program will specify tests, demonstrations, examinations, and analyses, and describe procedures to conduct and document testing necessary to verify meeting Monitored Geologic Repository requirements for a safe and effective geologic repository for radioactive waste. This test program will provide assurance that the repository is performing as designed, and that the barriers perform as expected; it will also develop supporting documentation to support the licensing process and to demonstrate compliance with codes, standards, and regulations. This comprehensive program addresses all aspects of verification from the development of test requirements to the performance of tests and reporting of the test results. The ''Monitored Geologic Repository Test & Evaluation Plan'' provides a detailed description of the test program approach necessary to achieve the above test program objectives. This test plan incorporates a set of test phases focused on ensuring repository safety and operational readiness and implements a project-wide integrated product management team approach to facilitate test program planning, analysis, and implementation. The following sections provide a description of the individual test phases, the methodology for test program planning and analyses, and the management approach for implementing these activities.

  14. Dose–response tests and semi-field evaluation of lethal and sub-lethal effects of slow release pyriproxyfen granules (Sumilarv®0.5G) for the control of the malaria vectors Anopheles gambiae sensu lato

    Science.gov (United States)

    2013-01-01

    Background Recently research has shown that larviciding can be an effective tool for integrated malaria vector control. Nevertheless, the uptake of this intervention has been hampered by the need to re-apply larvicides frequently. There is a need to explore persistent, environmentally friendly larvicides for malaria vector control to reduce intervention efforts and costs by reducing the frequency of application. In this study, the efficacy of a 0.5% pyriproxyfen granule (Surmilarv®0.5G, Sumitomo Chemicals) was assessed for the control of Anopheles gambiae sensu stricto and Anopheles arabiensis, the major malaria vectors in sub-Saharan Africa. Methods Dose–response and standardized field tests were implemented following standard procedures of the World Health Organization’s Pesticide Evaluation Scheme to determine: (i) the susceptibility of vectors to this formulation; (ii) the residual activity and appropriate retreatment schedule for field application; and, (iii) sub-lethal impacts on the number and viability of eggs laid by adults after exposure to Sumilarv®0.5G during larval development. Results Anopheles gambiae s.s. and An. arabiensis were highly susceptible to Sumilarv®0.5G. Estimated emergence inhibition (EI) values were very low and similar for both species. The minimum dosage that completely inhibited adult emergence was between 0.01-0.03 parts per million (ppm) active ingredient (ai). Compared to the untreated control, an application of 0.018 ppm ai prevented 85% (95% confidence interval (CI) 82%-88%) of adult emergence over six weeks under standardized field conditions. A fivefold increase in dosage of 0.09 ppm ai prevented 97% (95% CI 94%-98%) emergence. Significant sub-lethal effects were observed in the standardized field tests. Female An. gambiae s.s. that were exposed to 0.018 ppm ai as larvae laid 47% less eggs, and females exposed to 0.09 ppm ai laid 74% less eggs than females that were unexposed to the treatment. Furthermore, 77

  15. Component evaluation testing and analysis algorithms.

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Darren M.; Merchant, Bion John

    2011-10-01

    The Ground-Based Monitoring R&E Component Evaluation project performs testing on the hardware components that make up Seismic and Infrasound monitoring systems. The majority of the testing is focused on the Digital Waveform Recorder (DWR), Seismic Sensor, and Infrasound Sensor. In order to guarantee consistency, traceability, and visibility into the results of the testing process, it is necessary to document the test and analysis procedures that are in place. Other reports document the testing procedures that are in place (Kromer, 2007). This document serves to provide a comprehensive overview of the analysis and the algorithms that are applied to the Component Evaluation testing. A brief summary of each test is included to provide the context for the analysis that is to be performed.

  16. Magnetic Field Apparatus (MFA) Hardware Test

    Science.gov (United States)

    Anderson, Ken; Boody, April; Reed, Dave; Wang, Chung; Stuckey, Bob; Cox, Dave

    1999-01-01

    The objectives of this study are threefold: (1) Provide insight into water delivery in microgravity and determine optimal germination paper wetting for subsequent seed germination in microgravity; (2) Observe the behavior of water exposed to a strong localized magnetic field in microgravity; and (3) Simulate the flow of fixative (using water) through the hardware. The Magnetic Field Apparatus (MFA) is a new piece of hardware slated to fly on the Space Shuttle in early 2001. MFA is designed to expose plant tissue to magnets in a microgravity environment, deliver water to the plant tissue, record photographic images of plant tissue, and deliver fixative to the plant tissue.

  17. Results from laboratory and field testing of nitrate measuring spectrophotometers

    Science.gov (United States)

    Snazelle, Teri T.

    2015-01-01

    Five ultraviolet (UV) spectrophotometer nitrate analyzers were evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) during a two-phase evaluation. In Phase I, the TriOS ProPs (10-millimeter (mm) path length), Hach NITRATAX plus sc (5-mm path length), Satlantic Submersible UV Nitrate Analyzer (SUNA, 10-mm path length), and S::CAN Spectro::lyser (5-mm path length) were evaluated in the HIF Water-Quality Servicing Laboratory to determine the validity of the manufacturer's technical specifications for accuracy, limit of linearity (LOL), drift, and range of operating temperature. Accuracy specifications were met in the TriOS, Hach, and SUNA. The stock calibration of the S::CAN required two offset adjustments before the analyzer met the manufacturer's accuracy specification. Instrument drift was observed only in the S::CAN and was the result of leaching from the optical path insert seals. All tested models, except for the Hach, met their specified LOL in the laboratory testing. The Hach's range was found to be approximately 18 milligrams nitrogen per liter (mg-N/L) and not the manufacturer-specified 25 mg-N/L. Measurements by all of the tested analyzers showed signs of hysteresis in the operating temperature tests. Only the SUNA measurements demonstrated excessive noise and instability in temperatures above 20 degrees Celsius (°C). The SUNA analyzer was returned to the manufacturer at the completion of the Phase II field deployment evaluation for repair and recalibration, and the performance of the sensor improved significantly.

  18. Field Cone Penetration Tests with Various Penetration Rates - Test Results

    DEFF Research Database (Denmark)

    Poulsen, Rikke; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    The test site is located at Nordre Ringgade near the town called Dronninglund in the northern Jutland in Denmark. The site area is relatively flat, and was chosen because it has a size of approximately 3 ha and contains a relatively thick deposit of silty soils. Furthermore the groundwater...... was encountered at approximately 0.2-0.6 m below the ground level. The soil stratigraphy of the test site was before test start identified by geotechnical borings results. The geotechnical borings indicated that the site contains of sandy silt with clay stripes from approx. 4.0 to 10 m. In the top the silty soil...... is very sandy with few clay stripes, and gradually the clay stripes increases wherefore the soil from approx. 10 m contains of clay with sandy silt stripes. Large soil sample was also collected from the test site in order to determine basic soil properties in the laboratory....

  19. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    Energy Technology Data Exchange (ETDEWEB)

    Susan S. Sorini; John F. Schabron; Joseph F. Rovani, Jr.

    2002-09-30

    Western Research Institute (WRI) has developed a new commercial product ready for technology transfer, the Diesel Dog{reg_sign} Portable Soil Test Kit, for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated as ASTM Method D 5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In June 2001, the Diesel Dog technology won an American Chemical Society Regional Industrial Innovations Award. To gain field experience with the new technology, Diesel Dog kits have been used for a variety of site evaluation and cleanup activities. Information gained from these activities has led to improvements in hardware configurations and additional insight into correlating Diesel Dog results with results from laboratory methods. The Wyoming Department of Environmental Quality (DEQ) used Diesel Dog Soil Test Kits to guide cleanups at a variety of sites throughout the state. ENSR, of Acton, Massachusetts, used a Diesel Dog Portable Soil Test Kit to evaluate sites in the Virgin Islands and Georgia. ChemTrack and the U.S. Army Corps of Engineers successfully used a test kit to guide excavation at an abandoned FAA fuel-contaminated site near Fairbanks, Alaska. Barenco, Inc. is using a Diesel Dog Portable Soil Test Kit for site evaluations in Canada. A small spill of diesel fuel was cleaned up in Laramie, Wyoming using a Diesel

  20. Laboratory and field based evaluation of chromatography ...

    Science.gov (United States)

    The Monitor for AeRosols and GAses in ambient air (MARGA) is an on-line ion-chromatography-based instrument designed for speciation of the inorganic gas and aerosol ammonium-nitrate-sulfate system. Previous work to characterize the performance of the MARGA has been primarily based on field comparison to other measurement methods to evaluate accuracy. While such studies are useful, the underlying reasons for disagreement among methods are not always clear. This study examines aspects of MARGA accuracy and precision specifically related to automated chromatography analysis. Using laboratory standards, analytical accuracy, precision, and method detection limits derived from the MARGA chromatography software are compared to an alternative software package (Chromeleon, Thermo Scientific Dionex). Field measurements are used to further evaluate instrument performance, including the MARGA’s use of an internal LiBr standard to control accuracy. Using gas/aerosol ratios and aerosol neutralization state as a case study, the impact of chromatography on measurement error is assessed. The new generation of on-line chromatography-based gas and particle measurement systems have many advantages, including simultaneous analysis of multiple pollutants. The Monitor for Aerosols and Gases in Ambient Air (MARGA) is such an instrument that is used in North America, Europe, and Asia for atmospheric process studies as well as routine monitoring. While the instrument has been evaluat

  1. Correlação entre testes para avaliação da qualidade de sementes de girassol e emergência das plântulas em campo Correlation between sunflower seeds quality evaluation tests and seedling emergence in field

    Directory of Open Access Journals (Sweden)

    Madelon Rodrigues Sá Braz

    2009-10-01

    Full Text Available A capacidade do teste de germinação para estimar o potencial de emergência de plântulas no campo diminui à medida que as condições do ambiente são desfavoráveis. No entanto, diferentes testes de vigor têm sido utilizados para identificar os lotes de sementes que apresentam melhor desempenho nessas situações. O objetivo do trabalho foi correlacionar os resultados dos testes conduzidos no laboratório com a emergência das plântulas de girassol em campo. Para isso, cinco lotes de sementes de girassol da cultivar 'Embrapa 122 V2000' foram submetidos aos testes de germinação e vigor (primeira contagem, classificação de plântulas, teste de frio, condutividade elétrica, emergência de plântulas em areia e em campo, índice de velocidade de emergência, envelhecimento acelerado e deterioração controlada. Em condições adversas, a emergência das plântulas de girassol em campo apresentou maior correlação com o vigor, avaliado pelos testes de envelhecimento acelerado, de deterioração controlada e de condutividade elétrica.The germination capacity test to estimate the potential of seedlings emergence in the field decreases when the environmental conditions are unfavorable. However, different vigour tests have been used to identify the seed lots that have better perform in these situations. The objective of this research was to correlate the results of tests conducted in the laboratory with the emergence of sunflower seedlings in the field. For this, five lots of seeds sunflower cultivar 'Embrapa 122 V2000' were submitted to the germination and vigour tests (first count, classification of seedlings, cold test, electrical conductivity, seedling emergence in sand and in the field, emergence speed index, accelerated aging and controlled deterioration. Under adverse conditions, the seed vigour evaluated by accelerated aging, controlled deterioration and electrical conductivity presented higher correlation with sunflower plant

  2. Further evaluation in field tests of the activity of three anthelmintics (fenbendazole, oxibendazole, and pyrantel pamoate) against the ascarid Parascaris equorum in horse foals on eight farms in Central Kentucky (2009-2010).

    Science.gov (United States)

    Lyons, Eugene T; Tolliver, Sharon C; Kuzmina, Tetiana A; Collins, Sandra S

    2011-10-01

    The activity of three anthelmintics (fenbendazole-FBZ; oxibendazole-OBZ; and pyrantel pamoate-PRT) was ascertained against the ascarid Parascaris equorum in horse foals on eight farms in Central Kentucky (2009-2010) in field tests. A total of 316 foals were treated, and 168 (53.2%) were passing ascarid eggs on the day of treatment. Evaluation of drug efficacy was determined qualitatively by comparing the number of foals passing ascarid eggs in their feces before and after treatment. The main purpose was to obtain data on current activity of these compounds against ascarids. Additionally, the objective was to compare these findings with those from earlier data on the efficacy of these three compounds on nematodes in foals in this geographical area. Efficacies (average) for the foals ranged for FBZ (10 mg/kg) from 50% to 100% (80%), for OBZ (10 mg/kg) from 75% to 100% (97%), and for PRT at 1× (6.6 mg base/kg) from 0% to 71% (2%) and at 2× (13.2 mg base/kg) 0% to 0% (0%). Although the efficacy varied among the drugs, combined data for all farms indicated a significant reduction of ascarid infections for FBZ (p < 0.0001) and OBZ (p < 0.0001) but not for PRT (p = 0.0953).

  3. 新疆水利厅试验场灌区干管管线工程地质评价%Evaluation of Engineering Geology of Main Pipeline in Test Field Irrigation Area of Xinjiang Water Conservancy Bureau

    Institute of Scientific and Technical Information of China (English)

    袁志伟

    2014-01-01

    新疆水利厅试验场灌区干管管线地处新疆天山北坡倾斜剥蚀冲积平原区及北部沙漠区南缘,水文地质及工程地质情况复杂,冻胀、侵蚀等问题也给工程施工带来较大困难。通过对灌区干管管线工程地质的评价,为类似工程的管线布置和设计施工提供参考和借鉴。%The test field of Xinjiang water conservancy bureau of main pipeline is in the tilt erosion alluvial plain area and north desert area of north slopes of Tianshan Mountains.Its hydrogeology and engineering geology is complex, frost heaving and erosion are also greater difficulties for engineering construction.By evaluating engineering geology of main pipeline of irrigation area, can private tech-nical reference for pipeline arrangement and design construction for similar projects.

  4. 500-kW DCHX pilot-plant evaluation testing

    Energy Technology Data Exchange (ETDEWEB)

    Hlinak, A.; Lee, T.; Loback, J.; Nichols, K.; Olander, R.; Oshmyansky, S.; Roberts, G.; Werner, D.

    1981-10-01

    Field tests with the 500 kW Direct Contact Pilot Plant were conducted utilizing brine from well Mesa 6-2. The tests were intended to develop comprehensive performance data, design criteria, and economic factors for the direct contact power plant. The tests were conducted in two phases. The first test phase was to determine specific component performance of the DCHX, turbine, condensers and pumps, and to evaluate chemical mass balances of non-condensible gases in the IC/sub 4/ loop and IC/sub 4/ in the brine stream. The second test phase was to provide a longer term run at nearly fixed operating conditions in order to evaluate plant performance and identify operating cost data for the pilot plant. During these tests the total accumulated run time on major system components exceeded 1180 hours with 777 hours on the turbine prime mover. Direct contact heat exchanger performance exceeded the design prediction.

  5. Field tests of the mobile robot Sherpa

    Energy Technology Data Exchange (ETDEWEB)

    Beaucourt, P. de; Garrec, P.; Morganti, P. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. des Procedes et Systemes Avances; Trouville, B. [Electricite de France (EDF), 78 - Chatou (France); Lucibello, P.; Nobile, M. [ENEA, Rome (Italy). Direzione Studi

    1995-12-31

    This paper summarizes recent demonstrations of the transport capabilities, inside nuclear buildings, of the six egged robot SHERPA, developed by the CEA (Atomic Energy Commission) robotic team. Results of the tests carried out at Chooz-B and Trino Vercellesse Nuclear Power Plants, respectively in June 1993 and in January 1994, in the framework of the European Community TELEMAN Programme, are presented. (authors). 10 refs., 13 figs.

  6. Collective Protection (ColPro) Field Testing

    Science.gov (United States)

    2011-09-28

    burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing...data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this... meiosis level, as defined by the test item specification. The ppbRAE®-like instruments may have a detection range of 1 to 9,999 mg/m3, accurate within

  7. Hydro-Balanced Stuffing Box field test

    Energy Technology Data Exchange (ETDEWEB)

    Giangiacomo, L.A.

    1999-05-28

    The Hydro-Balanced Stuffing Box is a seal assembly for polished rod pumping installations commonly used in oil and gas pumping well installations to contain produced well fluids. The improved stuffing box was developed and patented by Harold H. Palmour of The Palmour Group of Livingston, TX. The stuffing box is designed to reduce the incidence of seal leakage and to utilize an environmentally safe fluid, so that if there is any leakage, environmental damage is reduced or eliminated. The unit was tested on two wells at the Rocky Mountain Oilfield Testing Center. During the test period, the performance of the stuffing box was measured by monitoring the pressure on the tubing and the inner chamber with a Barton Two-pen recorder. The amount of safe fluid consumed, fluid leakage at the top of the stuffing box, pressure supplied from the nitrogen bottle, ambient temperature, and polish rod temperature was recorded. The stuffing box is capable of providing a better seal between well fluids an d the environment than conventional stuffing boxes. It allows the polished rod to operate cooler and with lubrication, extending the life of the packing elements, and reducing the amount of attention required to prevent leakage.

  8. Field Testing of Nano-PCM Enhanced Building Envelope Components

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, Kaushik [ORNL; Childs, Phillip W [ORNL; Atchley, Jerald Allen [ORNL

    2013-08-01

    The U.S. Department of Energy s (DOE) Building Technologies Program s goal of developing high-performance, energy efficient buildings will require more cost-effective, durable, energy efficient building envelopes. Forty-eight percent of the residential end-use energy consumption is spent on space heating and air conditioning. Reducing envelope-generated heating and cooling loads through application of phase change material (PCM)-enhanced envelope components can facilitate maximizing the energy efficiency of buildings. Field-testing of prototype envelope components is an important step in estimating their energy benefits. An innovative phase change material (nano-PCM) was developed with PCM encapsulated with expanded graphite (interconnected) nanosheets, which is highly conducive for enhanced thermal storage and energy distribution, and is shape-stable for convenient incorporation into lightweight building components. During 2012, two test walls with cellulose cavity insulation and prototype PCM-enhanced interior wallboards were installed in a natural exposure test (NET) facility at Charleston, SC. The first test wall was divided into four sections, which were separated by wood studs and thin layers of foam insulation. Two sections contained nano-PCM-enhanced wallboards: one was a three-layer structure, in which nano-PCM was sandwiched between two gypsum boards, and the other one had PCM dispersed homogeneously throughout graphite nanosheets-enhanced gypsum board. The second test wall also contained two sections with interior PCM wallboards; one contained nano-PCM dispersed homogeneously in gypsum and the other was gypsum board containing a commercial microencapsulated PCM (MEPCM) for comparison. Each test wall contained a section covered with gypsum board on the interior side, which served as control or a baseline for evaluation of the PCM wallboards. The walls were instrumented with arrays of thermocouples and heat flux transducers. Further, numerical modeling of

  9. Brahms Mobile Agents: Architecture and Field Tests

    Science.gov (United States)

    Clancey, William J.; Sierhuis, Maarten; Kaskiris, Charis; vanHoof, Ron

    2002-01-01

    We have developed a model-based, distributed architecture that integrates diverse components in a system designed for lunar and planetary surface operations: an astronaut's space suit, cameras, rover/All-Terrain Vehicle (ATV), robotic assistant, other personnel in a local habitat, and a remote mission support team (with time delay). Software processes, called agents, implemented in the Brahms language, run on multiple, mobile platforms. These mobile agents interpret and transform available data to help people and robotic systems coordinate their actions to make operations more safe and efficient. The Brahms-based mobile agent architecture (MAA) uses a novel combination of agent types so the software agents may understand and facilitate communications between people and between system components. A state-of-the-art spoken dialogue interface is integrated with Brahms models, supporting a speech-driven field observation record and rover command system (e.g., return here later and bring this back to the habitat ). This combination of agents, rover, and model-based spoken dialogue interface constitutes a personal assistant. An important aspect of the methodology involves first simulating the entire system in Brahms, then configuring the agents into a run-time system.

  10. Test of QED at critical field strength

    Energy Technology Data Exchange (ETDEWEB)

    Bula, C. [Princeton Univ., NJ (United States)

    1997-01-01

    In a new experiment at the Final Focus Test Beam at SLAC, a low-emittance 46.6 GeV electron beam is brought into collisions with terawatt pulses of 1054 nm or 527 nm wavelength from a Nd:glass laser. Peak laser intensities of 10{sup 18} W/cm{sup 2} have been achieved corresponding to a value of 0.6 for the parameter {eta} = e{epsilon}/m{omega}{sub 0}c. In this case, an electron that crosses the center of the laser pulse has near-unit interaction probability. Results are presented for multiphoton Compton scattering in which an electron interacts with up to four laser photons, in agreement with theoretical calculations.

  11. Vadose Zone Transport Field Study: Detailed Test Plan for Simulated Leak Tests

    Energy Technology Data Exchange (ETDEWEB)

    Ward, Anderson L.; Gee, Glendon W.

    2000-06-23

    This report describes controlled transport experiments at well-instrumented field tests to be conducted during FY 2000 in support of DOE?s Vadose Zone Transport Field Study (VZTFS). The VZTFS supports the Groundwater/Vadose Zone Integration Project Science and Technology Initiative. The field tests will improve understanding of field-scale transport and lead to the development or identification of efficient and cost-effective characterization methods. These methods will capture the extent of contaminant plumes using existing steel-cased boreholes. Specific objectives are to 1) identify mechanisms controlling transport processes in soils typical of the hydrogeologic conditions of Hanford?s waste disposal sites; 2) reduce uncertainty in conceptual models; 3) develop a detailed and accurate data base of hydraulic and transport parameters for validation of three-dimensional numerical models; and 4) identify and evaluate advanced, cost-effective characterization methods with the potential to assess changing conditions in the vadose zone, particularly as surrogates of currently undetectable high-risk contaminants. Pacific Northwest National Laboratory (PNNL) manages the VZTFS for DOE.

  12. Data Testing CIELO Evaluations with ICSBEP Benchmarks

    Energy Technology Data Exchange (ETDEWEB)

    Kahler, Albert Comstock [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-09

    We review criticality data testing performed at Los Alamos with a combination of ENDF/B-VII.1 + potential CIELO nuclear data evaluations. The goal of CIELO is to develop updated, best available evaluated nuclear data files for 1H, 16O, 56Fe, 235,238U and 239Pu. because the major international evaluated nuclear data libraries don’t agree on the internal cross section details of these most important nuclides.

  13. Role of energy systems in two intermittent field tests in women field hockey players

    NARCIS (Netherlands)

    Lemmink, Koen A. P. M.; Visscher, Susan H.

    2006-01-01

    The energetics of 2 field tests that reflect physical performance in intermittent sports (i.e., the Interval Shuttle Sprint Test [ISST] and the Interval Shuttle Run Test [ISRT]) were examined in 21 women field hockey players. The ISST required the players to perform 10 shuttle sprints starting every

  14. Testing and Evaluation of Multifunctional Smart Coatings

    Science.gov (United States)

    Buhrow, Jerry; Li, Wenyan; Jolley, Scott; Calle, Luz M.; Pearman, Benjamin; Zhang, Xuejun

    2015-01-01

    A smart coating system, based on pH sensitive microcontainers (microparticles and microcapsules) has been developed. Various corrosion inhibitors have been encapsulated and incorporated into commercial and formulated coatings to test the functionality imparted on the coating by the incorporation of the inhibitor microcontainers. Coated carbon steel and aluminum alloy panels were tested using salt immersion, salt fog, and coastal atmospheric exposure conditions. This paper provides the details on coating sample preparation, evaluation methods, as well as test results of the inhibiting function of smart coatings.

  15. Fatigue Sensor Evaluation Program Laboratory Test Report.

    Science.gov (United States)

    1975-10-01

    Evaluation Program - laboratory Test Report, " by John Y. Kaufman, Design Engineer, and it was prepared for publication by Sue Bardsley, Technical Aid ...fatigue sensor as an aid to this purpose. The laboratory test effort was based on collection of data from six types of tests and thirty-three...34 ’: « •IIIS ......... li : « rtrtintr : •* M» c f M i H ::::::;:• ;:« ...j . .... ..:. •f’ ::.::::: ^::|:::: n» VH ft;; ** ViH ! * 1 - •• •-•• ; i

  16. Evaluation of the Field Gradient Lattice Detector

    CERN Document Server

    AUTHOR|(CDS)2072983

    A novel Micro Pattern Gas Detector, named the Field Gradient Lattice Detector, has been implemented using technologies available to CERN’s Printed Circuit Workshop. Numerous prototypes based on various materials were constructed in different geometries and their gain performance has been studied using 55Fe and 109Cd X-ray sources in Argon-CO2 gas mixtures. Two axis (2D) prototype structures have been shown to provide stable gains of around 1000 while a 3D design, based on the same polyimide foils used in other MPGD elements, holds a gain of 5000 for 8.9 keV X-rays even at high rates of 22 kHz/mm2. At a gain of 3100, the device has been tested up to 1 MHz/mm2 and shows no signs of degradation in performance. The energy resolution of the 3D-in-polyimide is modest, around 40% for 5.9 keV X-rays and 30% if the source is collimated indicating a variation in gain over the 3x3 cm2 active area. Having the most promise for future applications, the 3D-in-polyimide design has been selected for testing with a custom-bu...

  17. Test-field method for mean-field coefficients with MHD background

    CERN Document Server

    Rheinhardt, M

    2010-01-01

    Aims: The test-field method for computing turbulent transport coefficients from simulations of hydromagnetic flows is extended to the regime with a magnetohydrodynamic (MHD) background. Methods: A generalized set of test equations is derived using both the induction equation and a modified momentum equation. By employing an additional set of auxiliary equations, we derive linear equations describing the response of the system to a set of prescribed test fields. Purely magnetic and MHD backgrounds are emulated by applying an electromotive force in the induction equation analogously to the ponderomotive force in the momentum equation. Both forces are chosen to have Roberts flow-like geometry. Results: Examples with an MHD background are studied where the previously used quasi-kinematic test-field method breaks down. In cases with homogeneous mean fields it is shown that the generalized test-field method produces the same results as the imposed-field method, where the field-aligned component of the actual electr...

  18. Waste Handling Equipment Devleopment Test and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    R.L. Tome

    1998-12-01

    The purpose of this study is to identify candidate Monitored Geologic Repository (MGR) surface waste handling equipment for development testing. This study will also identify strategies for performing the development tests. Development testing shall be implemented to support detail design and reduce design risks. Development testing shall be conducted to confirm design concepts, evaluate alternative design concepts, show the availability of needed technology, and provide design documentation. The candidate equipment will be selected from MGR surface waste handling equipment that is the responsibility of the Management and Operating Contractor (M&O) Surface Design Department. The equipment identified in this study is based on Viability Assessment (VA) design. The ''Monitored Geologic Repository Test and Evaluation Plan'' (MGR T&EP), Reference 5.1, was used as a basis for this study. The MGR T&EP reflects the extent of test planning and analysis that can be conducted, given the current status of the MGR requirements and latest VA design information. The MGR T&EP supports the appropriate sections in the license application (LA) in accordance with 10 CFR 60.2 1(c)(14). The MGR T&EP describes the following test activities: site characterization to confirm, by test and analysis, the suitability of the Yucca Mountain site for housing a geologic repository; development testing to investigate and document design concepts to reduce risk; qualification testing to verify equipment compliance with design requirements, specifications, and regulatory requirements; system testing to validate compliance with MGR requirements, which include the receipt, handling, retrieval, and disposal of waste; periodic performance testing to verify preclosure requirements and to demonstrate safe and reliable MGR operation; and performance confirmation modeling, testing, and analysis to verify adherence to postclosure regulatory requirements. Development test activities can be

  19. CMOS test and evaluation a physical perspective

    CERN Document Server

    Bhushan, Manjul

    2015-01-01

    This book extends test structure applications described in Microelectronic Test Struc­tures for CMOS Technology (Springer 2011) to digital CMOS product chips. Intended for engineering students and professionals, this book provides a single comprehensive source for evaluating CMOS technology and product test data from a basic knowledge of the physical behavior of the constituent components. Elementary circuits that exhibit key properties of complex CMOS chips are simulated and analyzed, and an integrated view of design, test and characterization is developed. Appropriately designed circuit monitors embedded in the CMOS chip serve to correlate CMOS technology models and circuit design tools to the hardware and also aid in test debug. Impact of silicon process variability, reliability, and power and performance sensitivities to a range of product application conditions are described. Circuit simulations exemplify the methodologies presented, and problems are included at the end of the chapters.

  20. Interbull validation test for genomic evaluations

    Science.gov (United States)

    Genomic evaluations (GEBV) can be validated by comparing GEBVs of bulls in the youngest age classes to the daughter yield deviations (DYD) that the bulls will receive later. The GEBV are calculated from truncated data where the last four years of phenotypic data are removed. The test consists of w...

  1. Toward a model for field-testing patient decision-support technologies : a qualitative field-testing study

    NARCIS (Netherlands)

    Evans, R.; Elwyn, G.; Edwards, A.; Watson, E.; Austoker, J.; Grol, R.P.T.M.

    2007-01-01

    BACKGROUND: Field-testing is a quality assurance criterion in the development of patient decision-support technologies (PDSTs), as identified in the consensus statement of the International Patient Decision Aids Standards Collaboration. We incorporated field-testing into the development of a Web-bas

  2. ROPS performance during field upset and static testing.

    Science.gov (United States)

    Harris, J R; McKenzie, E A; Etherton, J R; Cantis, D M; Ronaghi, M

    2010-01-01

    Agriculture remains one of the most hazardous occupations in the U.S. By conservative estimates, tractor overturns alone claim 120 lives annually. A rollover protective structure (ROPS) and a seatbelt are a highly effective engineering safety control that can prevent many of these fatalities and reduce the severity of injuries associated with tractor overturn. SAE J2194 is a consensus performance standard established for agricultural ROPS. According to this standard, satisfactory ROPS performance can be demonstrated through static testing, field upset testing, or impact testing. A previous modeling study suggested that static testing may underpredict the strain induced in a ROPS during afield upset. In the current study, field upset testing and laboratory static testing results were compared. Field upset testing included six rear and six side upset tests performed according to SAE J2194 guidelines. Additionally, static testing was performed on a ROPS of the same model. The results support findings from the modeling study. Near the lowest sections of the ROPS, the plastic strain resulting from rear upset testing exceeded the plastic strain from static testing for 18 of 24 data points. Conversely, the ROPS plastic strain from side upset testing was typically less than plastic strain from laboratory static testing. However, data indicate that the side upset test may not be very repeatable. This study suggests that the longitudinal loading energy criterion for static testing might not be a conservative predictor of rear upset ROPS response.

  3. Probe Station and Near-Field Scanner for Testing Antennas

    Science.gov (United States)

    Zaman, Afroz; Lee, Richard Q.; Darby, William G.; Barr, Philip J.; Miranda, Felix A.; Lambert, Kevin

    2006-01-01

    A facility that includes a probe station and a scanning open-ended waveguide probe for measuring near electromagnetic fields has been added to Glenn Research Center's suite of antenna-testing facilities, at a small fraction of the cost of the other facilities. This facility is designed specifically for nondestructive characterization of the radiation patterns of miniaturized microwave antennas fabricated on semiconductor and dielectric wafer substrates, including active antennas that are difficult to test in traditional antenna-testing ranges because of fragility, smallness, or severity of DC-bias or test-fixture requirements. By virtue of the simple fact that a greater fraction of radiated power can be captured in a near-field measurement than in a conventional far-field measurement, this near-field facility is convenient for testing miniaturized antennas with low gains.

  4. Power Evaluation of Focused Cluster Tests.

    Science.gov (United States)

    Puett, Rc; Lawson, Ab; Clark, Ab; Hebert, Jr; Kulldorff, M

    2010-09-01

    Many statistical tests have been developed to assess the significance of clusters of disease located around known sources of environmental contaminants, also known as focused disease clusters. The majority of focused-cluster tests were designed to detect a particular spatial pattern of clustering, one in which the disease cluster centers around the pollution source and declines in a radial fashion with distance. However, other spatial patterns of environmentally related disease clusters are likely given that the spatial dispersion patterns of environmental contaminants, and thus human exposure, depend on a number of factors (i.e., meteorology and topography). For this study, data were simulated with five different spatial patterns of disease clusters, reflecting potential pollutant dispersion scenarios: 1) a radial effect decreasing with increasing distance, 2) a radial effect with a defined peak and decreasing with distance, 3) a simple angular effect, 4) an angular effect decreasing with increasing distance and 5) an angular effect with a defined peak and decreasing with distance. The power to detect each type of spatially distributed disease cluster was evaluated using Stone's Maximum Likelihood Ratio Test, Tango's Focused Test, Bithell's Linear Risk Score Test, and variations of the Lawson-Waller Score Test. Study findings underscore the importance of considering environmental contaminant dispersion patterns, particularly directional effects, with respect to focused-cluster test selection in cluster investigations. The effect of extra variation in risk also is considered, although its effect is not substantial in terms of the power of tests.

  5. Field Evaluation of Calypte’s AWARE™ Blood Serum Plasma (BSP) and Oral Mucosal Transudate (OMT) Rapid Tests for Detecting Antibodies to HIV-1 and 2 in Plasma and Oral Fluid

    Science.gov (United States)

    Alemnji, George A; Ngulefac, Gisele A; Ndumbe, Peter M; Asonganyi, Tazoacha

    2009-01-01

    As programs to prevent and care for HIV-infected persons are scaled-up in Africa, there is the need for continuous evaluation of the performance of test kits that could best support these programs. The present study evaluated the sensitivity, specificity, ease of use, and cost of AWARE ™ Blood Serum Plasma (BSP) and Oral Mucosal Transudate (OMT) Rapid HIV-1/2 test kits using real-time and archived samples of HIV-infected persons from Cameroon. Matched whole blood and OMT specimens were collected prospectively from HIV-positive and HIV-negative persons from different regions of Cameroon and tested using the AWARE ™ BSP and OMT test kits, respectively. These results were compared to the gold standard that included a combination of Determine HIV-1/2 and Enzygnost HIV-1/2. The BSP Rapid test kit was further evaluated using well characterized panels of HIV-2 and HIV-1 group O samples. Cost and end-user analysis of the OMT test kit was done by comparing its actual cost, consumables, safety, bench time and manipulation with other test kits. Of the 732 matched samples, 412 (56.3%) and 320 (43.7%) were from females and males, respectively. Of these samples, 23 (3.1%) gave discordant results between Determine HIV-1/2 and Enzygnost HIV1/2 and were excluded from the analysis. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the AWARE™ BSP were 100%. The AWARE™ OMT had 98.8% sensitivity, 98.9% specificity, 98.0% PPV and 99.4% NPV. The results of a well-characterized archived panel of HIV-2 (n=7) and HIV-1 group O (n=3) samples using the AWARE™ BSP Rapid test kit gave 100% concordance. Total per patient cost of the AWARE OMT rapid test kit was US$4.72 compared to a mean cost of US $7.33 ± 0.11 for the other test kits. Both the AWARE™ BSP and OMT Rapid test kits demonstrated high sensitivities and specificities on all samples tested and were well adapted for use in resource-constrained settings with high HIV

  6. Field evaluation of Calypte's AWARE blood serum plasma (BSP) and oral mucosal transudate (OMT) rapid tests for detecting antibodies to HIV-1 and 2 in plasma and oral fluid.

    Science.gov (United States)

    Alemnji, George A; Ngulefac, Gisele A; Ndumbe, Peter M; Asonganyi, Tazoacha

    2009-03-19

    As programs to prevent and care for HIV-infected persons are scaled-up in Africa, there is the need for continuous evaluation of the performance of test kits that could best support these programs. The present study evaluated the sensitivity, specificity, ease of use, and cost of AWARE Blood Serum Plasma (BSP) and Oral Mucosal Transudate (OMT) Rapid HIV-1/2 test kits using real-time and archived samples of HIV-infected persons from Cameroon. Matched whole blood and OMT specimens were collected prospectively from HIV-positive and HIV-negative persons from different regions of Cameroon and tested using the AWARE BSP and OMT test kits, respectively. These results were compared to the gold standard that included a combination of Determine HIV-1/2 and Enzygnost HIV-1/2. The BSP Rapid test kit was further evaluated using well characterized panels of HIV-2 and HIV-1 group O samples. Cost and end-user analysis of the OMT test kit was done by comparing its actual cost, consumables, safety, bench time and manipulation with other test kits. Of the 732 matched samples, 412 (56.3%) and 320 (43.7%) were from females and males, respectively. Of these samples, 23 (3.1%) gave discordant results between Determine HIV-1/2 and Enzygnost HIV1/2 and were excluded from the analysis. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the AWARE BSP were 100%. The AWARE OMT had 98.8% sensitivity, 98.9% specificity, 98.0% PPV and 99.4% NPV. The results of a well-characterized archived panel of HIV-2 (n=7) and HIV-1 group O (n=3) samples using the AWARE BSP Rapid test kit gave 100% concordance. Total per patient cost of the AWARE OMT rapid test kit was US dollars 4.72 compared to a mean cost of US dollars 7.33 +/- 0.11 for the other test kits. Both the AWARE BSP and OMT Rapid test kits demonstrated high sensitivities and specificities on all samples tested and were well adapted for use in resource-constrained settings with high HIV

  7. The 2007 Census Test: evaluation of key objectives.

    Science.gov (United States)

    Compton, Garnett

    2008-01-01

    The Office for National Statistics conducted a major census field test in May and June 2007 as part of the planning and preparation for the next census of population and housing in England and Wales in 2011. The 2007 Census Test was a large scale test covering approximately 100,000 household in five local authorities (LAs) selected to reflect a range of geographic conditions and social characteristics. Within England the Test covered parts of Bath and North East Somerset, Camden, Liverpool and Stoke on Trent. In Wales the Test took place in Carmarthenshire. The selected LAs were chosen to provide a varied cross section of the population and types of housing that would be covered in a full census. This article summarises the evaluation results and, where decided, decisions for 2011 on four key aspects of the Test: delivery method - post-out compared with hand delivery; inclusion of an income question; outsourcing recruitment, training and pay; and liaison with LAs.

  8. Development of a specific anaerobic field test for aerobic gymnastics.

    Science.gov (United States)

    Alves, Christiano Robles Rodrigues; Borelli, Marcello Tadeu Caetano; Paineli, Vitor de Salles; Azevedo, Rafael de Almeida; Borelli, Claudia Cristine Gomes; Lancha Junior, Antônio Herbert; Gualano, Bruno; Artioli, Guilherme Giannini

    2015-01-01

    The current investigation aimed to develop a valid specific field test to evaluate anaerobic physical performance in Aerobic Gymnastics athletes. We first designed the Specific Aerobic Gymnast Anaerobic Test (SAGAT), which included gymnastics-specific elements performed in maximal repeated sprint fashion, with a total duration of 80-90 s. In order to validate the SAGAT, three independent sub-studies were performed to evaluate the concurrent validity (Study I, n=8), the reliability (Study II, n=10) and the sensitivity (Study III, n=30) of the test in elite female athletes. In Study I, a positive correlation was shown between lower-body Wingate test and SAGAT performance (Mean power: p = 0.03, r = -0.69, CI: -0.94 to 0.03 and Peak power: p = 0.02, r = -0.72, CI: -0.95 to -0.04) and between upper-body Wingate test and SAGAT performance (Mean power: p = 0.03, r = -0.67, CI: -0.94 to 0.02 and Peak power: p = 0.03, r = -0.69, CI: -0.94 to 0.03). Additionally, plasma lactate was similarly increased in response to SAGAT (p = 0.002), lower-body Wingate Test (p = 0.021) and a simulated competition (p = 0.007). In Study II, no differences were found between the time to complete the SAGAT in repeated trials (p = 0.84; Cohen's d effect size = 0.09; ICC = 0.97, CI: 0.89 to 0.99; MDC95 = 0.12 s). Finally, in Study III the time to complete the SAGAT was significantly lower during the competition cycle when compared to the period before the preparatory cycle (p Gymnastics training period. Taken together, these data have demonstrated that SAGAT is a specific, reliable and sensitive measurement of specific anaerobic performance in elite female Aerobic Gymnastics, presenting great potential to be largely applied in training settings.

  9. Testing Some Pedo-Transfer Functions (PTFs in Apulia Region. Evaluation on the Basis of Soil Particle Size Distribution and Organic Matter Content for Estimating Field Capacity and Wilting Point

    Directory of Open Access Journals (Sweden)

    Floriano Buccigrossi

    2010-10-01

    Full Text Available The knowledge of soil water retention vs. soil water matric potential is applied to study irrigation and drainage scheduling, soil water storage capacity (plant available water, solute movement, plant growth and water stress. To measure field capacity and wilting point is expensive, laborious and is time consuming, so, frequently, matemathic models, called pedo-transfer functions (PTFs are utilized to estimate field capacity and wilting point through physical-chemical soil characteristics. Six PTFs have been evaluated (Gupta and Larson, 1979; Rawls et al., 1982; De Jong et al., 1983; Rawls and Brakensiek, 1985; Saxton et al., 1986; Vereecken et al., 1989 by comparing measured soil moisture values with estimated ones at soil water matric potential of -33 and -1500 kPa. Soil samples were collected (361 from 185 pedons of Apulian Region (Southern Italy. Accuracy of the soil moisture predictions is quantified with Root Mean Square Deviation (RMSD between estimated and measured water retention values. In Apulia Region the tested PTFs give different results on soils grouped on the basis of textural composition and organic matter (O.M. content both at the Field Capacity (FC and Wilting Point (WP. At the FC, Gupta and Larson model has given the best performance in Clayey (C, Sandy clay loam (SaCL, Sandy loam (SaL and Silty (Si soil, in loamy and tendency silty soils with O.M. content less than 1.9% and in tendency sandy soils with O.M. content less than 1.5% and greater than 2%; the Rawls model in Silty clay (SiC and Silty loam (SiL soils, in tendency clayey soils with O.M. less than 2.3% and in loamy and tendency silty soils with O.M. greater than 1.9%; the Rawls and Brakensiek model in tendency sandy soils with O.M. content between 1.5 and 2%; the Saxton model in Silty clay loam (SiCL, Loamy sand (LSa soils and in tendency clayey soils with O.M. content greater than 2.3% and the Vereecken model in Sandy clay (SaC, Loamy (L, Clay loam (CL and Sandy (Sa

  10. [A literature analysis of power frequency electric field testing data].

    Science.gov (United States)

    Zhang, Suli; Guo, Zehua; Yu, Xintian; Ding, Yan; Zhu, Zhiliang

    2015-06-01

    To analyze the literature on power frequency electric field testing data and to propose views and suggestions for current testing. The literature on power frequency electric field testing data published in the previous years was searched to identify 306 articles involving 193 valid testing data. Mann-Whitney test and Wilcoxon W test were used for analyzing the testing data. The classification of data was carried out according to one quarter of occupational exposure limit (1.25 kV/m), one half of the exposure limit (2.5 kV/m), and the exposure limit (5 kV/m). The structure of testing data showed a significant difference between the non-power facility group and the power facility group (Pelectric field is extensive. However, the power frequency electric field testing data in actual workplaces except high-voltage power facilities are far less than the occupational exposure limit with little harmfulness. There is a phenomenon of excessive testing at present.

  11. Field Testing Research at the NWTC (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2015-02-01

    The National Wind Technology Center (NWTC) at the National Renewable Laboratory (NREL) has extensive field testing capabilities that have been used in collaboration with the wind industry to accelerate wind technology development and deployment for more than 30 years.

  12. 25th Test and Evaluation National Conference

    Science.gov (United States)

    2009-03-05

    Auditory Displays Tactile / Haptic Displays Input Devices & Controls State Dependent Design Human Factors Engineering Taxonomy Visual and Auditory...Charles McQueary, Director, Operational Test & Evaluation (DOT&E) ROUNDTABLE : REALITIES FACING THE WORLD OF DEFENSE AND HOMELAND SECURITY T&E...aM roundtable: realitieS facing the World of defenSe and homeland Security t&e Moderator: Maj Gen Steve Sargeant, USAF, Commander AFOTEC MG

  13. Field tests and commercialization of natural gas leak detectors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, D.S.; Jeon, J.S.; Kim, K.D.; Cho, Y.A. [R and D Center, Korea Gas Corporation, Ansan (Korea)

    1999-09-01

    Objectives - (1) fields test of industrial gas leak detection monitoring system. (2) commericialization of residential gas leak detector. Contents - (1) five sets of gas leak detection monitoring system were installed at natural gas transmition facilities and tested long term stability and their performance. (2) improved residential gas leak detector was commercialised. Expected benefits and application fields - (1) contribution to the improvement of domestic gas sensor technology. (2) localization of fabrication technology for gas leak detectors. 23 refs., 126 figs., 37 tabs.

  14. Evaluation test of ALIS in Cambodia for humanitarian demining

    Science.gov (United States)

    Sato, Motoyuki

    2010-04-01

    ALIS is a hand-held dual sensor developed by Tohoku University, Japan since 2002. Dual sensor is a general name of sensor for humanitarian demining, which are equipped with metal detector and GPR. ALIS is only one hand-held dual sensor, which can record the sensor position with sensor signals. Therefore, the data can be processed after data acquisition, and can increase the imaging capability. ALIS has been tested in some mine affected courtiers including Afghanistan (2004), Egypt(2005), Croatia(2006-) and Cambodia(2007-). Mine fields at each country has different conditions and soil types. Therefore testes at the real mine fields are very important. ALIS has detected more than 30 AP-Mines in evaluation test in Cambodia held in 2009.

  15. Testing of a one dimensional model for Field II calibration

    DEFF Research Database (Denmark)

    Bæk, David; Jensen, Jørgen Arendt; Willatzen, Morten

    2008-01-01

    to the calibrated Field II program for 1, 4, and 10 cycle excitations. Two parameter sets were applied for modeling, one real valued Pz27 parameter set, manufacturer supplied, and one complex valued parameter set found in literature, Alguer´o et al. [11]. The latter implicitly accounts for attenuation. Results show......Field II is a program for simulating ultrasound transducer fields. It is capable of calculating the emitted and pulse-echoed fields for both pulsed and continuous wave transducers. To make it fully calibrated a model of the transducer’s electro-mechanical impulse response must be included. We...... examine an adapted one dimensional transducer model originally proposed by Willatzen [9] to calibrate Field II. This model is modified to calculate the required impulse responses needed by Field II for a calibrated field pressure and external circuit current calculation. The testing has been performed...

  16. Cone Factors from Field Vane and Triaxial Tests in Danish Soils

    DEFF Research Database (Denmark)

    Luke, Kirsten

    1996-01-01

    Six Danish cohesive soils are investigated using Cone Penetration Test (CPT) to estimate the undrained shear strength, cu. Field vane tests and consolidated triaxial tests are used to estimate cu for the six soils. The tested soils all come up with cone factors very close to 10 when using cu from...... the triaxial tests whereas cone factors ranging from 7 to 11 are estimated by using measurements from field vane tests. A strong correlation between the cone factor, Nkt and the friction ratio, fR is obtained when the cone factor is estimated from vane tests. This relation, which is obtained using only the six...... thoroughly investigated soils, is tested on data from other Danish and international sites. Likewise the constant cone factor of Nkt = 10 obtained from the triaxial tests is evaluated and compared with cone factors obtained from triaxial tests in other countries....

  17. Model to Test Electric Field Comparisons in a Composite Fairing Cavity

    Science.gov (United States)

    Trout, Dawn H.; Burford, Janessa

    2013-01-01

    Evaluating the impact of radio frequency transmission in vehicle fairings is important to sensitive spacecraft. This study shows cumulative distribution function (CDF) comparisons of composite a fairing electromagnetic field data obtained by computational electromagnetic 3D full wave modeling and laboratory testing. This work is an extension of the bare aluminum fairing perfect electric conductor (PEC) model. Test and model data correlation is shown.

  18. Contrast sensivity in test field with bright surround.

    NARCIS (Netherlands)

    Schreuder, D.A.

    1965-01-01

    A set of curves and two empirical formulas have been derived which represent the contrast sensivity of the human eye when both the test-object and the test-field luminance are considerable lower than the adaption level. Although derived to be used for the lighting of traffic tunnels, the data may be

  19. Field testing of high-efficiency supermarket refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Walker, D. (Foster-Miller, Inc., Waltham, MA (United States))

    1992-12-01

    The Electric Power Research Institute (EPRI) has undertaken a field test to quantify the performance of high-efficiency supermarket refrigeration. The initial work on this project was presented in EPRI report CU-6268 Supermarket Refrigeration Modeling and Field Demonstration.'' The information given here was generated through continued testing at the field test site. The field test was conducted at a supermarket owned by Safeway Stores, Inc., that was located in Menlo Park, CA. Testing was performed with the existing conventional refrigeration system and a high-efficiency multiplex refrigeration system that was installed for these tests. The results of the testing showed that the high-efficiency multiplex system reduced refrigeration energy consumption by 23.9% and peak electric demand for refrigeration by 30.0%. Analyses of these savings showed that the largest portion was due to the use of high-efficiency compressors (29.5% of total saving). Floating head pressure control, ambient and mechanical subcooling, compressor multiplexing and hot gas defrost accounted for 50% of total savings. The remainder of the savings (20.5%) were attributed to the use of an evaporative condenser. Tests were also conducted with several retrofit technologies. The most promising results were obtained with external liquid-suction heat exchangers installed at the outlets of the display cases. Favorable paybacks were calculated for these exchangers when they were used with very low and low temperature refrigeration.

  20. Differential Gender Performance on the Major Field Test-Business

    Science.gov (United States)

    Bielinska-Kwapisz, Agnieszka; Brown, F. William

    2013-01-01

    The Major Field Test in Business (MFT-B), a standardized assessment test of business knowledge among undergraduate business seniors, is widely used to measure student achievement. Many previous studies analyzing scores on the MFT-B report gender differences on the exam even after controlling for student's aptitude, general intellectual ability,…

  1. [Neuropad test in evaluation of diabetic foot].

    Science.gov (United States)

    Vieru, Alexandra; Niţă, Otilia; Graur, Lidia Iuliana; Mazilu, Georgiana; Mihalache, Laura; Popescu, Raluca Maria; Graur, Mariana

    2012-01-01

    Diabetic neuropathy (DN) is the main cause of foot ulceration. One of the earliest modifications is the loss of normal sudomotor function, a sign of autonomic neuropathy. The aim of this study is to evaluate sudomotor dysfunction using a new tool (Neuropad) in diabetic patients with foot ulceration. We included 58 diabetic patients with foot ulceration admitted in 2010 in the Clinical Center for Diabetes, Nutrition and Metabolic Diseases. We collected data regarding age, gender, type and duration of diabetes, glycated hemoglobin (HbAlc), history of amputations and duration of hospital admission. Peripheral neuropathy was evaluated through the Neuropathy Disability Score (NDS) and autonomic neuropathy was tested through Neuropad. 95% of patients had NDS > or = 6, among which 76% had also positive Neuropad test. Patients with both peripheral and autonomic neuropathy had longer duration of diabetes (p = 0.027) but similar HbA1c as patients with only peripheral neuropathy (p = 0.09). The former also had longer duration of current admission (p = 0.022) and a higher percentage of these patients had history of amputations (p = 0.041). Neuropad is a reliable, easy to use test for the diagnosis of autonomic neuropathy, which puts patients at greater risk for foot ulceration and amputation.

  2. HOW AUTOMATED TESTING TOOLS ARE SHOWING ITS IMPACT IN THE FIELD OF SOFTWARE TESTING

    Directory of Open Access Journals (Sweden)

    Deepti Gaur

    2012-09-01

    Full Text Available As, we know that Software testing is a very vast field inSoftware development life cycle. In this paper, we describethat how automated testing tools are very much convenientand easy to use which also makes testing faster and moreeffective in less time. Actually the world of technologyrevolves at fast pace today and among all Testing tools onlyautomated testing tools makes Software testing moresignificant and effective.

  3. Vadose zone transport field study: Detailed test plan for simulated leak tests

    Energy Technology Data Exchange (ETDEWEB)

    AL Ward; GW Gee

    2000-06-23

    Hanford to: identify mechanisms controlling transport processes in soils typical of the hydrogeologic conditions of Hanford's waste disposal sites; reduce uncertainty in conceptual models; develop a detailed and accurate database of hydraulic and transport parameters for validation of three-dimensional numerical models; identify and evaluate advanced, cost-effective characterization methods with the potential to assess changing conditions in the vadose zone, particularly as surrogates of currently undetectable high-risk contaminants. This plan provides details for conducting field tests during FY 2000 to accomplish these objectives. Details of additional testing during FY 2001 and FY 2002 will be developed as part of the work planning process implemented by the Integration Project.

  4. Hydraulic test for evaluation of hydrophone VSP

    Energy Technology Data Exchange (ETDEWEB)

    Yabuuchi, Satoshi; Koide, Kaoru [Power Reactor and Nuclear Fuel Development Corp., Toki, Gifu (Japan). Tono Geoscience Center

    1997-12-01

    This hydraulic test was carried out at the test site of Tono Geoscience Center, Mizunami-shi, Gifu Pref. in order to evaluate the reliability of the hydraulic conductivity estimated from hydrophone VSP experiment. From March to April 1997, we carried out measurements of pore-water pressure at five depths and permeability tests at seven depths down to G.L.-300m, within a borehole drilled in granitic rock. We compared the results of hydraulic test with hydrophone VSP experiment on condition that a single open fracture existed, and we obtained two notable results. First, for the granitic rock at which a single open fracture was found by BTV and also detected by hydrophone VSP experiment, the hydraulic conductivity was 1.54 x 10{sup -7} cm/sec, while for the same granitic rock at which another single open fracture was found by BTV but not detected by hydrophone VSP experiment, the hydraulic conductivity was less than 6 x 10{sup -10} cm/sec. Second, we converted the hydraulic conductivity of 1.54 x 10{sup -7} cm/sec which was obtained in a hydraulic test section of length 2.5 m into an equivalent value for a single open fracture of width 1 mm. The converted value (3.8 x 10{sup -4} cm/sec) was similar to the hydraulic conductivity estimated from hydrophone VSP experiment. In conclusion, the hydraulic test result shows that hydrophone VSP is useful to estimate an approximate hydraulic conductivity of a single open fracture. (author)

  5. Comparative evaluation of Rose Bengal plate agglutination test, mallein test, and some conventional serological tests for diagnosis of equine glanders.

    Science.gov (United States)

    Naureen, Abeera; Saqib, Muhammad; Muhammad, Ghulan; Hussain, Muhammad H; Asi, Muhammad N

    2007-07-01

    The Rose Bengal plate agglutination test (RBT) was evaluated for the diagnosis of equine glanders, and its diagnostic efficiency was compared with that of mallein and other serological tests, including indirect hemagglutination test (IHAT), complement fixation test (CFT), and modified counter immunoelectrophoresis test (mCIET). Sera from 70 naturally infected culture-positive, 96 potentially exposed cohorts, and 110 healthy equines were tested. All tests but mCIET showed 100% specificity when testing the sera from glanders-negative equines. The calculated sensitivities of RBT, IHAT, CFT, mCIET, and mallein test when testing culture-positive equines were 90.0, 97.1, 91.4, 81.4, and 75.7%, respectively. The RBT was significantly (P glandered and nonglandered animals, the highest agreement (0.987) was found between RBT and CFT followed by RBT and IHAT (0.940), RBT and mallein test (0.871), and RBT and mCIET (0.852). Because the RBT is simpler and rapid to perform, the inclusion of the test as a supplementary test for the diagnosis of glanders in field conditions is recommended.

  6. Evaluation of an electric field sensor for nondestructive material inspection

    Science.gov (United States)

    Kalyanasundaram, Kayatri; Arunachalam, Kavitha

    2013-01-01

    An electric field sensor is fabricated on a 125 micron thick flexible dielectric substrate for electromagnetic (EM) nondestructive material inspection at 915 MHz. The sensor consists of an electrically short dipole antenna and a radio frequency (RF) diode detector connected to a pair of high impedance screen printed carbon lines. The DC component of the rectified diode voltage conveyed across the high impedance lines is measured using a data acquisition circuit. Sensor measurements are validated with simulated data for a conformal patch antenna operating at 915 MHz. Sensor performance for EM nondestructive testing (NDT) is evaluated using phantom defects in low loss dielectric slabs. Preliminary results indicate sensor utility for EM NDT and support further testing on realistic defects.

  7. Testing of Photomultiplier Tubes in a Magnetic Field

    Science.gov (United States)

    Waldron, Zachary; A1 Collaboration

    2016-09-01

    The A1 collaboration at MAMI in Mainz, Germany has designed a neutron detector that can be used in experiments to measure the electric form factor of the neutron. They will measure elastic scattering from the neutron, using the polarized electron beam from MAMI at A1's experimental hall. The detector will be composed of two walls of staggered scintillator bars which will be read out by photomultiplier tubes (PMT), connected to both ends of each scintillator via light guides. The experiment requires a magnetic field with strength of 1 Tesla, 2m away from the first scintillator wall. The resulting fringe field is sufficient to disrupt the PMTs, despite the addition of Mu Metal shielding. The effects of the fringe field on these PMTs was tested to optimize the amplification of the PMTs. A Helmholtz Coil was designed to generate a controlled magnetic field with equivalent strength to the field that the PMTs will encounter. The PMTs were read out using a multi-channel analyzer, were tested at various angles relative to the magnetic field in order to determine the optimal orientation to minimize signal disruption. Tests were also performed to determine: the neutron detector response to cosmic radiation; and the best method for measuring a magnetic field's strength in two dimensions. National Science Foundation Grant No. IIA-1358175.

  8. Criteria evaluation for cleanliness testing phase 0

    Energy Technology Data Exchange (ETDEWEB)

    Meltzer, Michael [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Koester, Carolyn [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Stefanni, Chris [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    1999-02-04

    The Boeing Company (Boeing) contracted with Lawrence Livermore National Laboratory (LLNL) to develop criteria for evaluating the efficacy of its parts cleaning processes. In particular, LLNL and Boeing are attempting to identify levels of contamination that lead to parts failures. Sufficient contamination to cause impairment of anodizing, alodining, painting, or welding operations is considered a "part failure." In the "Phase 0" part of the project that was recently completed, preliminary analyses of aluminum substrates were performed as a first step in determining suitable cleanliness criteria for actual Boeing parts made from this material. A wide spread of contamination levels was specified for the Phase 0 test coupons, in the hopes of finding a range in which an appropriate cleanliness specification might lie. It was planned that, based on the results of the Phase 0 testing, further more detailed analyses ("Phase 1 testing") would be performed in order to more accurately identify the most appropriate criteria. For the Phase 0 testing, Boeing supplied LLNL with 3" x 6" and 3" x 10" aluminum test panels which LLNL contaminated with measured amounts of typical hydrocarbon substances encountered in Boeing' s fabrication operations. The panels were then subjected by Boeing to normal cleaning procedures, after which they went through one of the following sets of operations: l anodizing and primer painting . alodining (chromating) and primer painting l welding The coatings or welds were then examined by both Boeing and LLNL to determine whether any of the operations were impaired, and whether there was a correlation between contamination level and damage to the parts. The experimental approach and results are described in detail.

  9. DOE Field Operations Program EV and HEV Testing

    Energy Technology Data Exchange (ETDEWEB)

    Francfort, James Edward; Slezak, L. A.

    2001-10-01

    The United States Department of Energy’s (DOE) Field Operations Program tests advanced technology vehicles (ATVs) and disseminates the testing results to provide fleet managers and other potential ATV users with accurate and unbiased information on vehicle performance. The ATVs (including electric, hybrid, and other alternative fuel vehicles) are tested using one or more methods - Baseline Performance Testing (EVAmerica and Pomona Loop), Accelerated Reliability Testing, and Fleet Testing. The Program (http://ev.inel.gov/sop) and its nine industry testing partners have tested over 30 full-size electric vehicle (EV) models and they have accumulated over 4 million miles of EV testing experience since 1994. In conjunction with several original equipment manufacturers, the Program has developed testing procedures for the new classes of hybrid, urban, and neighborhood EVs. The testing of these vehicles started during 2001. The EVS 18 presentation will include (1) EV and hybrid electric vehicle (HEV) test results, (2) operating experience with and performance trends of various EV and HEV models, and (3) experience with operating hydrogen-fueled vehicles. Data presented for EVs will include vehicle efficiency (km/kWh), average distance driven per charge, and range testing results. The HEV data will include operating considerations, fuel use rates, and range testing results.

  10. A Field Test of the New Portable Gamma Spectrometry System

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Jung-Ki; Park, Uk Ryang; Park, Seunghoon; Chung, Heejun; Kwak, Sung-Woo [Korea Institute of Nuclear Non-proliferation and Control, Daejeon (Korea, Republic of); Kim, Yongkwn [NuCare Medical Systems, Inc., Incheon (Korea, Republic of)

    2015-10-15

    In order to perform a field test of the system, the measurement of U-235 enrichment for nuclear fuel pellets was conducted along with the IAEA Physical Inventory Verification (PIV) inspection at the KEPCO Nuclear Fuel (KNF). The enrichment value of U-235 was calculated based on the total counts of the 185.7 keV photopeak and compared with the reference line, drawn by certified sources. The goal of this study is to experimentally evaluate the system performance of the developed system. In this study, the new portable gamma spectrometry system showed a good linearity (R{sup 2}=1) but overestimated the enrichment values than IAEA inspection device. It could be caused by the stability of the new system since it found, right after this measurement, that the accuracy of the system gradually increases and becomes stable over time. Further steps will optimize the design parameter based on these results and repeat measurement with the same samples under the same environment.

  11. Rigorously testing multialternative decision field theory against random utility models.

    Science.gov (United States)

    Berkowitsch, Nicolas A J; Scheibehenne, Benjamin; Rieskamp, Jörg

    2014-06-01

    Cognitive models of decision making aim to explain the process underlying observed choices. Here, we test a sequential sampling model of decision making, multialternative decision field theory (MDFT; Roe, Busemeyer, & Townsend, 2001), on empirical grounds and compare it against 2 established random utility models of choice: the probit and the logit model. Using a within-subject experimental design, participants in 2 studies repeatedly choose among sets of options (consumer products) described on several attributes. The results of Study 1 showed that all models predicted participants' choices equally well. In Study 2, in which the choice sets were explicitly designed to distinguish the models, MDFT had an advantage in predicting the observed choices. Study 2 further revealed the occurrence of multiple context effects within single participants, indicating an interdependent evaluation of choice options and correlations between different context effects. In sum, the results indicate that sequential sampling models can provide relevant insights into the cognitive process underlying preferential choices and thus can lead to better choice predictions.

  12. Interim Report of Field Test of Expedient Pavement Repairs (Test Items 1-15).

    Science.gov (United States)

    1980-03-01

    OF FIELD TEST OFEXPEDIENT PAVEMENT REPAIRS ( TEST ITEMS 1-15). RAYMONDS.4OLLINGS lWGINE E :AH1 DIVISION .I MARŜ 6 // il) JNTEIM REPUT TiJUL1077...Pavement Repairs ( Test Items 1-15) 6 PERFORMING ORG. REPORT NUMBER 7. AUTHOR(&) S. CONTRACT OR GRANT NUMBER(&) Raymond S. Rollings 9. PERFORMING...21 Item 14 Test Results .................... 33 22 Density Results, Item 15....................34 23 Summary of Test Items ......................37 24

  13. Smart Infrared Inspection System Field Operational Test Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Siekmann, Adam [ORNL; Capps, Gary J [ORNL; Franzese, Oscar [ORNL; Lascurain, Mary Beth [ORNL

    2011-06-01

    The Smart InfraRed Inspection System (SIRIS) is a tool designed to assist inspectors in determining which vehicles passing through the SIRIS system are in need of further inspection by measuring the thermal data from the wheel components. As a vehicle enters the system, infrared cameras on the road measure temperatures of the brakes, tires, and wheel bearings on both wheel ends of commercial motor vehicles (CMVs) in motion. This thermal data is then presented to enforcement personal inside of the inspection station on a user friendly interface. Vehicles that are suspected to have a violation are automatically alerted to the enforcement staff. The main goal of the SIRIS field operational test (FOT) was to collect data to evaluate the performance of the prototype system and determine the viability of such a system being used for commercial motor vehicle enforcement. From March 2010 to September 2010, ORNL facilitated the SIRIS FOT at the Greene County Inspection Station (IS) in Greeneville, Tennessee. During the course of the FOT, 413 CMVs were given a North American Standard (NAS) Level-1 inspection. Of those 413 CMVs, 384 were subjected to a SIRIS screening. A total of 36 (9.38%) of the vehicles were flagged by SIRIS as having one or more thermal issues; with brakes issues making up 33 (91.67%) of those. Of the 36 vehicles flagged as having thermal issues, 31 (86.11%) were found to have a violation and 30 (83.33%) of those vehicles were placed out-of-service (OOS). Overall the enforcement personnel who have used SIRIS for screening purposes have had positive feedback on the potential of SIRIS. With improvements in detection algorithms and stability, the system will be beneficial to the CMV enforcement community and increase overall trooper productivity by accurately identifying a higher percentage of CMVs to be placed OOS with minimal error. No future evaluation of SIRIS has been deemed necessary and specifications for a production system will soon be drafted.

  14. DEVELOPMENT AND FIELD EVALUATION OF LIQUID ...

    African Journals Online (AJOL)

    ACSS

    2016-02-26

    Feb 26, 2016 ... ... were evaluated. In microcosm assays, plants inoculated with these .... soil, where they will be introduced (Jardim-Freire,. 1997; Denton ..... in a study carried out in Chile, in which peanut ..... Australian Centre for International.

  15. Field Testing of Low-Cost Bio-Based Phase Change Material

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, Kaushik [ORNL; Childs, Phillip W [ORNL; Atchley, Jerald Allen [ORNL

    2013-03-01

    A test wall built with phase change material (PCM)-enhanced loose-fill cavity insulation was monitored for a period of about a year in the warm-humid climate of Charleston, South Carolina. The test wall was divided into various sections, one of which contained only loose-fill insulation and served as a control for comparing and evaluating the wall sections with the PCM-enhanced insulation. This report summarizes the findings of the field test.

  16. Field tests-low input, side-wall vented boiler

    Energy Technology Data Exchange (ETDEWEB)

    Litzke, W.L.; Butcher, T.A.; Celebi, Y. [Brookhaven National Lab., Upton, NY (United States)

    1996-07-01

    The Fan Atomized Burner (FAB) was developed at Brookhaven National Laboratory as part of the Oil Heat Combustion Equipment Technology Program to provide a practical low-firing rate technology leading to new, high efficiency oil-fired appliances. The development of the burner design and results of application testing have been presented in prior oil heat conferences over the past several years. This information is also summarized in a more comprehensive BNL report. The first field trial of a prototype unit was initiated during the 1994-95 heating season. This paper presents the results of the second year of testing, during the 1995-96 heating season. The field tests enable the demonstration of the reliability and performance of the FAB under practical, typical operating conditions. Another important objective of the field test was to demonstrate that the low input is adequate to satisfy the heating and hot water demands of the household. During the first field trial it was shown that at a maximum input rate of 0.4 gph (55,000 Btu/hr) the burner was able to heat a home with over 2,000 square feet of conditioned living space and provide adequate supply of domestic hot water for a family of six. The test is located in Long Island, NY.

  17. U.S. field testing programs and results

    Energy Technology Data Exchange (ETDEWEB)

    Wicks, G.G.

    2000-06-09

    The United States has been active in four major international in-situ or field testing programs over the past two decades, involving the burial of simulated high-level waste forms and package components. These programs are designed to supplement laboratory testing studies in order to obtain the most complete and realistic picture possible of waste glass behavior under realistic repository-relevant conditions.

  18. SuperTools Test and Evaluation Plan

    Energy Technology Data Exchange (ETDEWEB)

    Mannos, Tom J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Mixed Signal ASIC Design

    2017-01-01

    Superconducting electronics (SCE) represents a potential path to efficient exascale computing for HPC and data center applications, but SCE-based circuit design lags far behind its CMOS equivalent. IARPA’s ongoing C3 program and its developing SuperTools program aim to jumpstart SCE R&D with the near-term goal of producing a high-speed, low-energy, 64-bit RISC processor using Josephson Junction based logic cells. SuperTools performers will develop software tools for efficient SCE design and accurate simulation and characterization of JJ-based circuits, which include the RSFQ, RQL, and AQFP logic families. T&E teams from NIST, MIT Lincoln Lab, Berkeley Lab, and Sandia National Labs will evaluate the tools and fabricate test circuits to compare with simulated results. The five-year, three-phase program includes 48 performer deliverables, three annual technical exchange meetings, and annual site visits.

  19. Sequential accelerated tests: Improving the correlation of accelerated tests to module performance in the field

    Science.gov (United States)

    Felder, Thomas; Gambogi, William; Stika, Katherine; Yu, Bao-Ling; Bradley, Alex; Hu, Hongjie; Garreau-Iles, Lucie; Trout, T. John

    2016-09-01

    DuPont has been working steadily to develop accelerated backsheet tests that correlate with solar panels observations in the field. This report updates efforts in sequential testing. Single exposure tests are more commonly used and can be completed more quickly, and certain tests provide helpful predictions of certain backsheet failure modes. DuPont recommendations for single exposure tests are based on 25-year exposure levels for UV and humidity/temperature, and form a good basis for sequential test development. We recommend a sequential exposure of damp heat followed by UV then repetitions of thermal cycling and UVA. This sequence preserves 25-year exposure levels for humidity/temperature and UV, and correlates well with a large body of field observations. Measurements can be taken at intervals in the test, although the full test runs 10 months. A second, shorter sequential test based on damp heat and thermal cycling tests mechanical durability and correlates with loss of mechanical properties seen in the field. Ongoing work is directed toward shorter sequential tests that preserve good correlation to field data.

  20. Ability evaluation by binary tests: Problems, challenges & recent advances

    Science.gov (United States)

    Bashkansky, E.; Turetsky, V.

    2016-11-01

    Binary tests designed to measure abilities of objects under test (OUTs) are widely used in different fields of measurement theory and practice. The number of test items in such tests is usually very limited. The response to each test item provides only one bit of information per OUT. The problem of correct ability assessment is even more complicated, when the levels of difficulty of the test items are unknown beforehand. This fact makes the search for effective ways of planning and processing the results of such tests highly relevant. In recent years, there has been some progress in this direction, generated by both the development of computational tools and the emergence of new ideas. The latter are associated with the use of so-called “scale invariant item response models”. Together with maximum likelihood estimation (MLE) approach, they helped to solve some problems of engineering and proficiency testing. However, several issues related to the assessment of uncertainties, replications scheduling, the use of placebo, as well as evaluation of multidimensional abilities still present a challenge for researchers. The authors attempt to outline the ways to solve the above problems.

  1. Test chambers for cell culture in static magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Glinka, Marek, E-mail: mag@iq.pl [Research and Development Centre of Electrical Machines. 188 Rozdzienskiego Street, 40-203 Katowice (Poland); Gawron, Stanisław, E-mail: s.gawron@komel.katowice.pl [Research and Development Centre of Electrical Machines. 188 Rozdzienskiego Street, 40-203 Katowice (Poland); Sieroń, Aleksander, E-mail: sieron1@tlen.pl [Department of Internal Diseases, Angiology and Physical Medicine in Bytom. Medical University of Silesia in Katowice. 15 Batorego Street, 41-902 Bytom (Poland); Pawłowska–Góral, Katarzyna, E-mail: kgoral@sum.edu.pl [Department of Food and Nutrition in Sosnowiec. Medical University of Silesia in Katowice. 8 Jednosci Street, 41-200 Sosnowiec (Poland); Cieślar, Grzegorz, E-mail: cieslar1@tlen.pl [Department of Internal Diseases, Angiology and Physical Medicine in Bytom. Medical University of Silesia in Katowice. 15 Batorego Street, 41-902 Bytom (Poland); Sieroń–Stołtny, Karolina [Department of Internal Diseases, Angiology and Physical Medicine in Bytom. Medical University of Silesia in Katowice. 15 Batorego Street, 41-902 Bytom (Poland)

    2013-04-15

    Article presents a test chamber intended to be used for in vitro cell culture in homogenous constant magnetic field with parametrically variable magnitude. We constructed test chambers with constant parameters of control homeostasis of cell culture for the different parameters of static magnetic field. The next step was the computer calculation of 2D and 3D simulation of the static magnetic field distribution in the chamber. The analysis of 2D and 3D calculations of magnetic induction in the cells' exposition plane reveals, in comparison to the detection results, the greater accuracy of 2D calculations (Figs. 9 and 10). The divergence in 2D method was 2–4% and 8 to 10% in 3D method (reaching 10% only out of the cells′ cultures margins). -- Highlights: ► We present test chamber to be used for in vitro cell culture in static magnetic field. ► The technical data of the chamber construction was presented. ► 2D versus 3D simulation of static magnetic field distribution in chamber was reported. ► We report the accuracy of 2D calculation than 3D.

  2. INTERMITTENT VERSUS CONTINUOUS INCREMENTAL FIELD TESTS: ARE MAXIMAL VARIABLES INTERCHANGEABLE?

    Directory of Open Access Journals (Sweden)

    Lorival J. Carminatti

    2013-03-01

    Full Text Available The aim of the present study was to compare physiological responses derived from an incremental progressive field test with a constant speed test i.e. intermittent versus continuous protocol. Two progressive maximum tests (Carminatti`s test (T-CAR and the Vameval test (T-VAM, characterized by increasing speed were used. T-CAR is an intermittent incremental test, performed as shuttle runs; while T-VAM is a continuous incremental test performed on an athletic track. Eighteen physically active, healthy young subjects (21.9 ± 2.0 years; 76.5 ± 8.6 kg, 1.78 ± 0.08 m, 11.2 ± 5.4% body fat, volunteered for this study. Subjects performed four different maximum test sessions conducted in the field: two incremental tests and two time to exhaustion tests (TTE at peak test velocities (PV. No significant differences were found for PV (T-CAR = 15.6 ± 1.2; T-VAM = 15.5 ± 1.3 km·h-1 and maximal HR (T-CAR = 195 ± 11; T- VAM = 194 ± 14 bpm. During TTE, there were no significant differences for HR (TTET-CAR and TTET-VAM = 192 ± 12 bpm. However, there was a significant difference in TTE (p = 0.04 (TTET-CAR = 379 ± 84, TTET-VAM = 338 ± 58 s with a low correlation (r = 0.41. The blood lactate concentration measured at the end of the TTE tests, showed no significant difference (TTET-CAR = 13.2 ± 2.4 vs. TTET-VAM = 12.9 ± 2.4 mmol·l-1. Based on the present findings, it is suggested that the maximal variables derived from T-CAR and T-VAM can be interchangeable in the design of training programs.

  3. Evaluation of nine HIV rapid test kits to develop a national HIV testing algorithm in Nigeria

    Directory of Open Access Journals (Sweden)

    Orji Bassey

    2015-05-01

    Full Text Available Background: Non-cold chain-dependent HIV rapid testing has been adopted in many resource-constrained nations as a strategy for reaching out to populations. HIV rapid test kits (RTKs have the advantage of ease of use, low operational cost and short turnaround times. Before 2005, different RTKs had been used in Nigeria without formal evaluation. Between 2005 and 2007, a study was conducted to formally evaluate a number of RTKs and construct HIV testing algorithms. Objectives: The objectives of this study were to assess and select HIV RTKs and develop national testing algorithms. Method: Nine RTKs were evaluated using 528 well-characterised plasma samples. These comprised 198 HIV-positive specimens (37.5% and 330 HIV-negative specimens (62.5%, collected nationally. Sensitivity and specificity were calculated with 95% confidence intervals for all nine RTKs singly and for serial and parallel combinations of six RTKs; and relative costs were estimated. Results: Six of the nine RTKs met the selection criteria, including minimum sensitivity and specificity (both ≥ 99.0% requirements. There were no significant differences in sensitivities or specificities of RTKs in the serial and parallel algorithms, but the cost of RTKs in parallel algorithms was twice that in serial algorithms. Consequently, three serial algorithms, comprising four test kits (BundiTM, DetermineTM, Stat-Pak® and Uni-GoldTM with 100.0% sensitivity and 99.1% – 100.0% specificity, were recommended and adopted as national interim testing algorithms in 2007. Conclusion: This evaluation provides the first evidence for reliable combinations of RTKs for HIV testing in Nigeria. However, these RTKs need further evaluation in the field (Phase II to re-validate their performance.

  4. The virtual fields method applied to spalling tests on concrete

    Science.gov (United States)

    Pierron, F.; Forquin, P.

    2012-08-01

    For one decade spalling techniques based on the use of a metallic Hopkinson bar put in contact with a concrete sample have been widely employed to characterize the dynamic tensile strength of concrete at strain-rates ranging from a few tens to two hundreds of s-1. However, the processing method mainly based on the use of the velocity profile measured on the rear free surface of the sample (Novikov formula) remains quite basic and an identification of the whole softening behaviour of the concrete is out of reach. In the present paper a new processing method is proposed based on the use of the Virtual Fields Method (VFM). First, a digital high speed camera is used to record the pictures of a grid glued on the specimen. Next, full-field measurements are used to obtain the axial displacement field at the surface of the specimen. Finally, a specific virtual field has been defined in the VFM equation to use the acceleration map as an alternative `load cell'. This method applied to three spalling tests allowed to identify Young's modulus during the test. It was shown that this modulus is constant during the initial compressive part of the test and decreases in the tensile part when micro-damage exists. It was also shown that in such a simple inertial test, it was possible to reconstruct average axial stress profiles using only the acceleration data. Then, it was possible to construct local stress-strain curves and derive a tensile strength value.

  5. Lorentz breaking Effective Field Theory and observational tests

    CERN Document Server

    Liberati, Stefano

    2012-01-01

    Analogue models of gravity have provided an experimentally realizable test field for our ideas on quantum field theory in curved spacetimes but they have also inspired the investigation of possible departures from exact Lorentz invariance at microscopic scales. In this role they have joined, and sometime anticipated, several quantum gravity models characterized by Lorentz breaking phenomenology. A crucial difference between these speculations and other ones associated to quantum gravity scenarios, is the possibility to carry out observational and experimental tests which have nowadays led to a broad range of constraints on departures from Lorentz invariance. We shall review here the effective field theory approach to Lorentz breaking in the matter sector, present the constraints provided by the available observations and finally discuss the implications of the persisting uncertainty on the composition of the ultra high energy cosmic rays for the constraints on the higher order, analogue gravity inspired, Lore...

  6. Acceptance test report: Field test of mixer pump for 241-AN-107 caustic addition project

    Energy Technology Data Exchange (ETDEWEB)

    Leshikar, G.A.

    1997-05-16

    The field acceptance test of a 75 HP mixer pump (Hazleton serial number N-20801) installed in Tank 241-AN-107 was conducted from October 1995 thru February 1996. The objectives defined in the acceptance test were successfully met, with two exceptions recorded. The acceptance test encompassed field verification of mixer pump turntable rotation set-up and operation, verification that the pump instrumentation functions within established limits, facilitation of baseline data collection from the mixer pump mounted ultrasonic instrumentation, verification of mixer pump water flush system operation and validation of a procedure for its operation, and several brief test runs (bump) of the mixer pump.

  7. Computational evaluation oa a neutron field facility

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Jose Julio de O.; Pazianotto, Mauricio T., E-mail: jjfilos@hotmail.com, E-mail: mpazianotto@gmail.com [Instituto Tecnologico de Aeronautica (ITA/DCTA), Sao Jose dos Campos, SP (Brazil); Federico, Claudio A.; Passaro, Angelo, E-mail: claudiofederico@ieav.cta.br, E-mail: angelo@ieav.cta.br [Instituto de Estudos Avancados (IEAv/DCTA), Sao Jose dos Campos, SP (Brazil)

    2015-07-01

    This paper describes the results of a study based on computer simulation for a realistic 3D model of Ionizing Radiation Laboratory of the Institute for Advanced Studies (IEAv) using the MCNP5 (Monte Carlo N-Particle) code, in order to guide the installing a neutron generator, produced by reaction {sup 3}H(d,n){sup 4}He. The equipment produces neutrons with energy of 14.1 MeV and 2 x 10{sup 8} n/s production rate in 4 πgeometry, which can also be used for neutron dosimetry studies. This work evaluated the spectra and neutron fluence provided on previously selected positions inside the facility, chosen due to the interest to evaluate the assessment of ambient dose equivalent so that they can be made the necessary adjustments to the installation to be consistent with the guidelines of radiation protection and radiation safety, determined by the standards of National Nuclear Energy Commission (CNEN). (author)

  8. Comparison of two field tests to estimate maximum aerobic speed.

    Science.gov (United States)

    Berthoin, S; Gerbeaux, M; Turpin, E; Guerrin, F; Lensel-Corbeil, G; Vandendorpe, F

    1994-08-01

    The measurement of maximal aerobic speed (MAS) and the prediction of maximal oxygen uptake (VO2 max) by means of field tests were carried out on 17 students studying physical education. The subjects underwent a continuous multi-stage track test (Léger and Boucher, 1980), shuttle test (Léger et al., 1984) and VO2 max measurement on a treadmill. The VO2 max values estimated using the track test (56.8 +/- 5.8 ml kg-1 min-1) were not significantly different from the values measured in the treadmill test (56.8 +/- 7.1 ml kg-1 min-1), but were higher than those estimated using the shuttle test (51.1 +/- 5.9 ml kg-1 min-1). The maximal nature of the tests was checked by measurement of heart rate and lactate concentration, taken within 2 min post-test. The means of the MAS observed in the track test (15.8 +/- 1.9 km h-1) and in the treadmill test (15.9 +/- 2.6 km h-1) were not significantly different (P > 0.10). The mean of the shuttle test MAS (13.1 +/- 1 km h-1) was significantly lower (P < 0.01) than those of the other tests. However, the MAS of the shuttle test and track test are linked. The equation for linear regression between MAS values in these two tests is MAStrack = 1.81 x MASshuttle -7.86 (r = 0.91), allowing estimation of one of these MAS values when the other is known. Thus these values may be used within diversified training.

  9. The Fourth Gravity Test and Quintessence Matter Field

    CERN Document Server

    Liu, Molin; Yu, Fei; Gui, Yuanxing

    2010-01-01

    After the previous work on gravitational frequency shift, light deflection (arXiv:1003.5296) and perihelion advance (arXiv:0812.2332), we calculate carefully the fourth gravity test, i.e. radar echo delay in a central gravity field surrounded by static free quintessence matter, in this paper. Through the Lagrangian method, we find the influence of the quintessence matter on the time delay of null particle is presence by means of an additional integral term. When the quintessence field vanishes, it reduces to the usual Schwarzschild case naturally. Meanwhile, we also use the data of the Viking lander from the Mars and Cassini spacecraft to Saturn to constrain the quintessence field. For the Viking case, the field parameter $\\alpha$ is under the order of $10^{-9}$. However, $\\alpha$ is under $10^{-18}$ for the Cassini case.

  10. The fourth gravity test and quintessence matter field

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Molin; Yu, Benhai [Xinyang Normal University, College of Physics and Electronic Engineering, Xinyang (China); Yu, Fei; Gui, Yuanxing [Dalian University of Technology, School of Physics and Optoelectronic Technology, Dalian (China)

    2010-06-15

    After the previous work on gravitational frequency shift, light deflection (Eur. Phys. J. C 59: 107-116, 2009) and perihelion advance (Eur. Phys. J. C 60: 175-179, 2009), we calculate carefully the fourth gravity test, i.e. radar echo delay in a central gravity field surrounded by static free quintessence matter, in this paper. Through the Lagrangian method, we find the influence of the quintessence matter on the time delay of null particle is presence by means of an additional integral term. When the quintessence field vanishes, it reduces to the usual Schwarzschild case naturally. Meanwhile, we also use the data of the Viking lander from the Mars and Cassini spacecraft to Saturn to constrain the quintessence field. For the Viking case, the field parameter {alpha} is under the order of 10{sup -9}. However, {alpha} is under 10{sup -18} for the Cassini case. (orig.)

  11. Test field for airborne laser scanning in Finland

    Science.gov (United States)

    Ahokas, E.; Kaartinen, H.; Kukko, A.; Litkey, P.

    2014-11-01

    Airborne laser scanning (ALS) is a widely spread operational measurement tool for obtaining 3D coordinates of the ground surface. There is a need for calibrating the ALS system and a test field for ALS was established at the end of 2013. The test field is situated in the city of Lahti, about 100 km to the north of Helsinki. The size of the area is approximately 3.5 km × 3.2 km. Reference data was collected with a mobile laser scanning (MLS) system assembled on a car roof. Some streets were measured both ways and most of them in one driving direction only. The MLS system of the Finnish Geodetic Institute (FGI) consists of a navigation system (NovAtel SPAN GNSS-IMU) and a laser scanner (FARO Focus3D 120). In addition to the MLS measurements more than 800 reference points were measured using a Trimble R8 VRS-GNSS system. Reference points are along the streets, on parking lots, and white pedestrian crossing line corners which can be used as reference targets. The National Land Survey of Finland has already used this test field this spring for calibrating their Leica ALS-70 scanner. Especially it was easier to determine the encoder scale factor parameter using this test field. Accuracy analysis of the MLS points showed that the point height RMSE is 2.8 cm and standard deviation is 2.6 cm. Our purpose is to measure both more MLS data and more reference points in the test field area to get a better spatial coverage. Calibration flight heights are planned to be 1000 m and 2500 m above ground level. A cross pattern, southwest-northeast and northwest-southeast, will be flown both in opposite directions.

  12. Deep Borehole Field Test Research Activities at LBNL

    Energy Technology Data Exchange (ETDEWEB)

    Dobson, Patrick [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Tsang, Chin-Fu [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Kneafsey, Timothy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Borglin, Sharon [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Piceno, Yvette [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Andersen, Gary [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Nakagawa, Seiji [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Nihei, Kurt [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rutqvist, Jonny [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Doughty, Christine [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Reagan, Matthew [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-08-19

    The goal of the U.S. Department of Energy Used Fuel Disposition’s (UFD) Deep Borehole Field Test is to drill two 5 km large-diameter boreholes: a characterization borehole with a bottom-hole diameter of 8.5 inches and a field test borehole with a bottom-hole diameter of 17 inches. These boreholes will be used to demonstrate the ability to drill such holes in crystalline rocks, effectively characterize the bedrock repository system using geophysical, geochemical, and hydrological techniques, and emplace and retrieve test waste packages. These studies will be used to test the deep borehole disposal concept, which requires a hydrologically isolated environment characterized by low permeability, stable fluid density, reducing fluid chemistry conditions, and an effective borehole seal. During FY16, Lawrence Berkeley National Laboratory scientists conducted a number of research studies to support the UFD Deep Borehole Field Test effort. This work included providing supporting data for the Los Alamos National Laboratory geologic framework model for the proposed deep borehole site, conducting an analog study using an extensive suite of geoscience data and samples from a deep (2.5 km) research borehole in Sweden, conducting laboratory experiments and coupled process modeling related to borehole seals, and developing a suite of potential techniques that could be applied to the characterization and monitoring of the deep borehole environment. The results of these studies are presented in this report.

  13. Latex agglutination test for field diagnosis of haemorrhagic septicaemia

    Directory of Open Access Journals (Sweden)

    Lily Natalia

    2002-10-01

    Full Text Available Pasteurella multocida is bacterial pathogens that cause haemorrhagic septicaemia (HS in cattle and buffaloes. Various tests have been used to differentiate types of P. multocida, as well as to diagnose this specific disease. A latex agglutination test has been developed for the detection of P. multocida B:2 which is the causal agent of HS. This test is a rapid and simple test suitable for local laboratorium to diagnose HS cases in the field. A heat stable antigen consisting of mainly lipopolysaccharide (LPS extract of formalin killed P. multocida 0019 was used to produce specific antibody against P. multocida B:2. The antiboy was then used to sensitise latex particles. Latex agglutination test have been used to screen some P. multocida field isolates and this test have been proven to be specific, simple and easy to be used in detecting P. multocida B:2. The specificity is due to antibodies recognising LPS or LPS protein complexes. Sensitised latex was stable at 4° C for at least12 months. This test should be used as an aid to diagnosis and employed principally to confirm and support clinical and post mortem findings of HS.

  14. Field Tests and Simulation of Lion-Head River Bridge

    Directory of Open Access Journals (Sweden)

    Yao-Min Fang

    2007-01-01

    Full Text Available Lion-Head River Bridge is a twin bridge in parallel position. The east-bounded was designed and constructed as a traditional prestress concrete box girder bridge with pot bearings; and the west-bounded was installed with seismic isolation devices of lead rubber bearings. The behavior of the isolated bridge is compared with that of the traditional bridge through several field tests including the ambient vibration test, the force vibration test induced by shakers, the free vibration test induced by a push and fast release system, and the truck test. The bridges suffered from various extents of damage due to the Chi-Chi and the Chi-I earthquakes of great strength during the construction and had been retrofitted. The damage was reflected by the change of the bridges' natural frequencies obtained from the ambient vibration tests. The models of the two bridges are simulated by the finite element method based on the original design drawings. Soil-structure interaction was also scrutinized in this study. The simulation was then modified based on the results from the field tests. Dynamic parameters of bridges are identified and compared with those from theoretical simulation. The efficiency is also verified to be better for an isolated bridge.

  15. The effect of performance feedback on cardiorespiratory fitness field tests.

    Science.gov (United States)

    Metsios, G S; Flouris, A D; Koutedakis, Y; Theodorakis, Y

    2006-06-01

    We investigated the effects of performance feedback (PF) on predicting maximal oxygen uptake (VO2 max) using the 20 m Multistage Shuttle Run Test (MST) and 20 m Square Shuttle Test (SST). The agreement between these two field tests in relation to laboratory VO2 max was also examined. Forty healthy males (age: 21.5+/-2.3; BMI: 23.7+/-2.0) randomly performed four indirect VO2 max tests; that is the MST and SST, as well as a modified version of MST (MSTMD) and SST (SSTMD). During MST and SST subjects received PF with respect to both test stage and running pace. In contrast, MSTMD and SSTMD incorporated auditory feedback which solely emitted signals regulating the running pace. Participants also performed a laboratory VO2 max treadmill test (TT). ANOVA demonstrated significant mean predicted VO2 max decrements in both MSTMD (pmax, the '95% limits of agreement' analysis indicated errors equal to 3.6+/-9.6 and 1.4+/-10.3 ml kg-1 min-1 with coefficients of variation of +/-10.0% and +/-10.9%, for MST and MSTMD, respectively. The corresponding '95% limits of agreement' values for SST and SSTMD were 0.1+/-5.0 and -1.1+/-6.1 ml kg-1 min-1 with coefficients of variation of +/-5.4% and +/-6.7%, respectively. It is concluded that the application of PF leads to superior field testing performances.

  16. Field Testing of a Portable Radiation Detector and Mapping System

    Energy Technology Data Exchange (ETDEWEB)

    Hofstetter, K.J. [Westinghouse Savannah River Company, AIKEN, SC (United States); Hayes, D.W.; Eakle, R.F.

    1998-03-01

    Researchers at the Savannah River Site (SRS) have developed a man- portable radiation detector and mapping system (RADMAPS) which integrates the accumulation of radiation information with precise ground locations. RADMAPS provides field personnel with the ability to detect, locate, and characterize nuclear material at a site or facility by analyzing the gamma or neutron spectra and correlating them with position. the man-portable field unit records gamma or neutron count rate information and its location, along with date and time, using an embedded Global Positioning System (GPS). RADMAPS is an advancement in data fusion, integrating several off-the-shelf technologies with new computer software resulting in a system that is simple to deploy and provides information useful to field personnel in an easily understandable form. Decisions on subsequent actions can be made in the field to efficiently use available field resources. The technologies employed in this system include: recording GPS, radiation detection (typically scintillation detectors), pulse height analysis, analog-to-digital converters, removable solid-state (Flash or SRAM) memory cards, Geographic Information System (GIS) software and personal computers with CD-ROM supporting digital base maps. RADMAPS includes several field deployable data acquisition systems designed to simultaneously record radiation and geographic positions. This paper summarizes the capabilities of RADMAPS and some of the results of field tests performed with the system.

  17. Comparison of two aerobic field tests in young tennis players.

    Science.gov (United States)

    Fargeas-Gluck, Marie-Agnès; Léger, Luc A

    2012-11-01

    This study compares the maximal responses of a new aerobic tennis field test, the NAVTEN to a known aerobic field test, often used with young tennis players, that is, the continuous multistage 20-m shuttle run test (20-m SRT). The NAVTEN is an intermittent (1-minute/1-minute) multistage test with side-to-side displacements and ball hitting. Ten young elite tennis players aged 12.9 ± 0.3 (mean ± SD) randomly performed both tests and were continuously monitored for heart rate (HR) and oxygen uptake (V[Combining Dot Above]O2) using the Vmax ST (Sensormedics). The 20-m SRT and NAVTEN show similar HRpeak (202 ± 6.1 vs. 208 ± 9.5, respectively) and V[Combining Dot Above]O2peak (54.2 ± 5.9 vs. 54.9 ± 6.0 ml·kg·min). Pearson correlations between both tests were 0.88 and 0.92 for V[Combining Dot Above]O2peak and maximal speed, respectively. The NAVTEN yielded V[Combining Dot Above]O2peak values that are typical for active subjects of that age and are similar to the 20-m SRT supporting its use to measure aerobic fitness of young tennis players in specific and entertaining field conditions. The fact that two-thirds of the tennis players achieved a different ranking (±1 rank) with the NAVTEN and the 20-m SRT suggests that the NAVTEN may be more specific than the 20-m SRT to assess aerobic fitness of tennis players. From a practical point of view, the NAVTEN test is more specific and pedagogical for young tennis players even though both tests yield similar maximal values.

  18. Medium and Heavy Duty Vehicle Field Evaluations (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Walkowicz, K.

    2014-06-01

    This presentation discusses field evaluations of medium- and heavy-duty vehicles performed by NREL. The project provides medium-duty (MD) and heavy-duty (HD) test results, aggregated data, and detailed analysis, including 3rd party unbiased data (data that would not normally be shared by industry in an aggregated and detailed manner). Over 5.6 million miles of advanced technology MD and HD truck data have been collected, documented, and analyzed on over 240 different vehicles since 2002. Data, analysis, and reports are shared within DOE, national laboratory partners, and industry for R&D planning and strategy. The results help guide R&D for new technology development, help define intelligent usage of newly developed technology, and help fleets/users understand all aspects of advanced technology.

  19. Field evaluation of herbal mosquito repellents.

    Science.gov (United States)

    Das, N G; Nath, D R; Baruah, I; Talukdar, P K; Das, S C

    1999-12-01

    Repellent properties of Zanthoxylum armatum DC. Syn. Z. alatum Roxb. (Timur), Curcuma aromatica (Jungli haldi) and Azadirachta indica (Neem) oils were evaluated against mosquitoes in mustard (Brassica sp.) and coconut (Cocos sp.) oil base and compared with synthetic repellent. Dimethyl phthalate (DMP) as standard. Timur and jungli haldi afforded better protection in the both the base at all the concentrations. Tepellents in mustard oil gave longer protection time than those in coconut oil. At 0.57 mg/cm2 concentration timur oil gave significantly higher protection both in mustard (445 min) as well as coconut oil (404 min) than the other repellents and DMP.

  20. A Novel Field-Deployable Point-of-Care Diagnostic Test for Cutaneous Leishmaniasis

    Science.gov (United States)

    2016-10-01

    OEF/OIF veteran population. To date, there is no field-standardized molecular method based on sensitive DNA amplification coupled with Lateral Flow...OEF/OIF veteran population. To date, there is no field-standardized molecular method based on sensitive DNA amplification coupled with Lateral Flow...FIOCRUZ to carry out Leishmania identification using the RPA-LF test. Collaboration: FIOCRUZ staff (PhD student ) collaborated in the evaluation of

  1. Evaluation of geostatistical parameters based on well tests; Estimation de parametres geostatistiques a partir de tests de puits

    Energy Technology Data Exchange (ETDEWEB)

    Gauthier, Y.

    1997-10-20

    Geostatistical tools are increasingly used to model permeability fields in subsurface reservoirs, which are considered as a particular random variable development depending of several geostatistical parameters such as variance and correlation length. The first part of the thesis is devoted to the study of relations existing between the transient well pressure (the well test) and the stochastic permeability field, using the apparent permeability concept.The well test performs a moving permeability average over larger and larger volume with increasing time. In the second part, the geostatistical parameters are evaluated using well test data; a Bayesian framework is used and parameters are estimated using the maximum likelihood principle by maximizing the well test data probability density function with respect to these parameters. This method, involving a well test fast evaluation, provides an estimation of the correlation length and the variance over different realizations of a two-dimensional permeability field

  2. Field-Based Concerns about Fourth-Generation Evaluation Theory.

    Science.gov (United States)

    Lai, Morris K.

    Some aspects of fourth generation evaluation procedures that have been advocated by E. G. Guba and Y. S. Lincoln were examined empirically, with emphasis on areas where there have been discrepancies between theory and field-based experience. In fourth generation evaluation, the product of an evaluation is not a set of conclusions, recommendations,…

  3. A Dutch Achievement Testing Program for Guidance and Program Evaluation.

    Science.gov (United States)

    Wijnstra, Johan M.

    1984-01-01

    The Eindtoets Basisonderwijs (final primary school test) is a Dutch national achievement test taken annually by 90,000 pupils. This article overviews the Dutch educational system and describes this testing program, emphasizing test equating methods. Evaluation findings from 1980 and resulting changes in test content and evaluation reports are also…

  4. A PILOT STUDY COMPARING TWO FIELD TESTS WITH THE TREADMILL RUN TEST IN SOCCER PLAYERS

    Directory of Open Access Journals (Sweden)

    Abdul Rashid Aziz

    2005-06-01

    Full Text Available This study compares the performances obtained during soccer-specific field tests of the 20 m multistage shuttle run test (MST and the Yo-Yo intermittent endurance test (YIET, with the measured maximal oxygen uptake (VO2max obtained in both field tests as well as that obtained in the traditional test of running to exhaustion on a treadmill (TRT, in young trained soccer players. Twenty-one National-level youth players performed, in random order, the MST and YIET to determine the relationship between the two field tests. From these, eight randomly chosen players performed their field tests as well as a TRT, equipped with an ambulatory gas exchange measurement device. Pearson correlation coefficient analysis showed that the players' performance (i.e. distance covered in the MST and YIET was correlated (r = 0.65, p 0.05. In contrast, significant correlations were observed between the players' performance in the MST with the measured VO2max obtained in the same MST and in the YIET (both p < 0.05; and attained almost statistical significance with the measured VO2max in the TRT (p = 0.06. The lack of association between distances covered in the YIET with all the measured VO2max values suggest that measured VO2max per se may not be suitable to characterize soccer players' intermittent endurance performance. In comparison with the MST, the YIET may be a more favourable field-based assessment of soccer player's endurance performance

  5. A possible field test for marine cloud brightening geoengineering. A possible field test for marine cloud brightening geoengineering

    Science.gov (United States)

    Gadian, A.; Wood, R.; Coe, H.; Latham, J.

    2011-12-01

    A possible field test for marine cloud brightening geoengineering. Abstract: The Marine Cloud Brightening (MCB) geoengineering technique (Latham et al 2008) hypothesizes that seeding marine stratocumulus clouds with copious quantities of roughly monodisperse sub-micrometre seawater particles can enhance the cloud droplet number concentration and increase cloud albedo. Here, we propose a set of field tests to critically assess the efficacy of the MCB geoengineering proposal over a limited area. The tests are de minimus with respect to their climate effects. The tests involve three phases, with increasing logistical complexity, each of which is designed to test one or more important components of the cloud brightening scheme. Each involves the introduction and monitoring of controlled aerosol perturbations from one or more ship-based seeding platforms up to a limited area of 100x100 km2. A suite of observational platforms of increasing number and complexity, including aircraft, ships and satellites, will observe the aerosol plume and in the later experiments the cloud and albedo responses to the aerosol perturbations. These responses must include the necessary cloud physical and chemical processes which determine the efficacy of the cloud brightening scheme. Since these processes are also central to the broader problem of aerosol-cloud-climate interactions, such field tests would have significant benefits for climate science in addition to providing a critical test of the MCB hypothesis. Such field experiments should be designed and conducted in an objective manner within the framework of emerging geoengineering research governance structures. Reference: Latham J. et al.. (2008) Global temperature stabilization via controlled albedo enhancement of low-level maritime clouds. Phil. Trans. R. Soc. A doi:10.1098/rsta.2008.0137

  6. Neuroethological validation of an experimental apparatus to evaluate oriented and non-oriented escape behaviours: Comparison between the polygonal arena with a burrow and the circular enclosure of an open-field test.

    Science.gov (United States)

    Biagioni, Audrey Francisco; dos Anjos-Garcia, Tayllon; Ullah, Farhad; Fisher, Isaac René; Falconi-Sobrinho, Luiz Luciano; de Freitas, Renato Leonardo; Felippotti, Tatiana Tocchini; Coimbra, Norberto Cysne

    2016-02-01

    Inhibition of GABAergic neural inputs to dorsal columns of the periaqueductal grey matter (dPAG), posterior (PH) and dorsomedial (DMH) hypothalamic nuclei elicits distinct types of escape behavioural reactions. To differentiate between the variety and intensity of panic-related behaviours, the pattern of defensive behaviours evoked by blockade of GABAA receptors in the DMH, PH and dPAG were compared in a circular open-field test and in a recently designed polygonal arena. In the circular open-field, the defensive behaviours induced by microinjection of bicuculline into DMH and PH were characterised by defensive alertness behaviour and vertical jumps preceded by rearing exploratory behaviour. On the other hand, explosive escape responses interspersed with horizontal jumps and freezing were observed after the blockade of GABAA receptors on dPAG neurons. In the polygonal arena apparatus, the escape response produced by GABAergic inhibition of DMH and PH neurons was directed towards the burrow. In contrast, the blockade of GABAA receptors in dPAG evoked non-oriented escape behaviour characterised by vigorous running and horizontal jumps in the arena. Our findings support the hypothesis that the hypothalamic nuclei organise oriented escape behavioural responses whereas non-oriented escape is elaborated by dPAG neurons. Additionally, the polygonal arena with a burrow made it easy to discriminate and characterise these two different patterns of escape behavioural responses. In this sense, the polygonal arena with a burrow can be considered a good methodological tool to discriminate between these two different patterns of escape behavioural responses and is very useful as a new experimental animal model of panic attacks.

  7. Large Field Photogrammetry Techniques in Aircraft and Spacecraft Impact Testing

    Science.gov (United States)

    Littell, Justin D.

    2010-01-01

    The Landing and Impact Research Facility (LandIR) at NASA Langley Research Center is a 240 ft. high A-frame structure which is used for full-scale crash testing of aircraft and rotorcraft vehicles. Because the LandIR provides a unique capability to introduce impact velocities in the forward and vertical directions, it is also serving as the facility for landing tests on full-scale and sub-scale Orion spacecraft mass simulators. Recently, a three-dimensional photogrammetry system was acquired to assist with the gathering of vehicle flight data before, throughout and after the impact. This data provides the basis for the post-test analysis and data reduction. Experimental setups for pendulum swing tests on vehicles having both forward and vertical velocities can extend to 50 x 50 x 50 foot cubes, while weather, vehicle geometry, and other constraints make each experimental setup unique to each test. This paper will discuss the specific calibration techniques for large fields of views, camera and lens selection, data processing, as well as best practice techniques learned from using the large field of view photogrammetry on a multitude of crash and landing test scenarios unique to the LandIR.

  8. Experimental evaluation of the Battelle accelerated test design for the solar array at Mead, Nebraska

    Science.gov (United States)

    Frickland, P. O.; Repar, J.

    1982-01-01

    A previously developed test design for accelerated aging of photovoltaic modules was experimentally evaluated. The studies included a review of relevant field experience, environmental chamber cycling of full size modules, and electrical and physical evaluation of the effects of accelerated aging during and after the tests. The test results indicated that thermally induced fatigue of the interconnects was the primary mode of module failure as measured by normalized power output. No chemical change in the silicone encapsulant was detectable after 360 test cycles.

  9. Experimental evaluation of the Battelle accelerated test design for the solar array at Mead, Nebraska

    Science.gov (United States)

    Frickland, P. O.; Repar, J.

    1982-04-01

    A previously developed test design for accelerated aging of photovoltaic modules was experimentally evaluated. The studies included a review of relevant field experience, environmental chamber cycling of full size modules, and electrical and physical evaluation of the effects of accelerated aging during and after the tests. The test results indicated that thermally induced fatigue of the interconnects was the primary mode of module failure as measured by normalized power output. No chemical change in the silicone encapsulant was detectable after 360 test cycles.

  10. The Fourth Gravity Test and Quintessence Matter Field

    OpenAIRE

    Liu, Molin; Yu, Benhai; Yu, Fei; Gui, Yuanxing

    2010-01-01

    After the previous work on gravitational frequency shift, light deflection (arXiv:1003.5296) and perihelion advance (arXiv:0812.2332), we calculate carefully the fourth gravity test, i.e. radar echo delay in a central gravity field surrounded by static free quintessence matter, in this paper. Through the Lagrangian method, we find the influence of the quintessence matter on the time delay of null particle is presence by means of an additional integral term. When the quintessence field vanishe...

  11. Evaluation of Surface Cracks Using Magnetic Flux Leakage Testing

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The magnetic field distribution characteristics of surface cracks with various widths are discussed based on finite element (FEM) results. The crack depth was 0.20 mm, the width range was from 0.02 to 1.00 mm. The results showed that crack width and lift-off (the distance between surface and sensor) will influence signals. Discussed in this paper is the influence of various lift-off parameters on the peak to peak values of the normal component in magnetic flux leakage testing. The effects can be applied to evaluate surface breaking cracks of different widths and depths.An idea is presented to smooth narrow, sharp crack tips using alternating current (AC) field magnetization.

  12. Overspinning BTZ black holes with test particles and fields

    Science.gov (United States)

    Düztaş, Koray

    2016-12-01

    It has been claimed that in a test of an asymptotically anti-de Sitter version of weak cosmic censorship conjecture by attempting to overspin a Bañados, Teitelboim, and Zanelli (BTZ) black hole with test particles, one finds that it is not possible to spin up the black hole past its extremal limit. The result of this analysis is restricted to the case where the initial black hole is extremal. We extend this analysis to find that massive test particles can overspin the black hole, if we start with a nearly extremal black hole, instead. We also consider the interaction of the BTZ black hole with test fields. We show that overspinning of nearly extremal black holes is possible whether or not there is super-radiance for the field. If there is super-radiance, overspinning occurs in a narrow range of frequencies bounded below by the super-radiant limit. However, if there is no super-radiance for the field, overspinning becomes generic and also applies to extremal black holes. This is in analogy with the Kerr case.

  13. A new test statistic for climate models that includes field and spatial dependencies using Gaussian Markov random fields

    Science.gov (United States)

    Nosedal-Sanchez, Alvaro; Jackson, Charles S.; Huerta, Gabriel

    2016-07-01

    A new test statistic for climate model evaluation has been developed that potentially mitigates some of the limitations that exist for observing and representing field and space dependencies of climate phenomena. Traditionally such dependencies have been ignored when climate models have been evaluated against observational data, which makes it difficult to assess whether any given model is simulating observed climate for the right reasons. The new statistic uses Gaussian Markov random fields for estimating field and space dependencies within a first-order grid point neighborhood structure. We illustrate the ability of Gaussian Markov random fields to represent empirical estimates of field and space covariances using "witch hat" graphs. We further use the new statistic to evaluate the tropical response of a climate model (CAM3.1) to changes in two parameters important to its representation of cloud and precipitation physics. Overall, the inclusion of dependency information did not alter significantly the recognition of those regions of parameter space that best approximated observations. However, there were some qualitative differences in the shape of the response surface that suggest how such a measure could affect estimates of model uncertainty.

  14. Test and evaluation capabilities at NAVELEXCEN Charleston

    Energy Technology Data Exchange (ETDEWEB)

    Stalvey, T.W.; Anderson, G.B.; Hinson, T.L. [Naval Electronic Systems Engineering Center, Charleston, SC (United States)

    1993-12-31

    The Environmental Systems and Instrumentation Engineering Department is located within the Special Programs Directorate of the Naval Electronic Systems Engineering Center (NAVELEXCEN Charleston). This Center is an echelon 4 Command under the Naval Command Control and Ocean Surveillance Center, San Diego (NCCOSC). NCCOSC is an echelon 3 Command under the Space and Warfare Systems Command (SPAWAR) which is located in Washington DC. Radiation Detection, Indication and Computation (RDIAC) equipment life-cycle management for the entire Navy falls under the auspices of the Naval Sea Systems Command (SEA 04R). The RADIAC Program provides centralized management for the execution of research, development, test, evaluation, maintenance, procurement, allowance, and equipment support for all Navy RADIAC instrumentation and assigned special monitoring equipments. RADIAC equipment is used throughout the Navy to support various functions associated with radioactivity, potential contamination, and personnel exposure to sources of ionizing radiation. Common sources in today`s Navy include nuclear reactors, nuclear weapons, industrial radiography, and nuclear medicine. Types of radiation includes gamma, x-ray, alpha, and beta.

  15. Finds in Testing Experiments for Model Evaluation

    Institute of Scientific and Technical Information of China (English)

    WU Ji; JIA Xiaoxia; LIU Chang; YANG Haiyan; LIU Chao

    2005-01-01

    To evaluate the fault location and the failure prediction models, simulation-based and code-based experiments were conducted to collect the required failure data. The PIE model was applied to simulate failures in the simulation-based experiment. Based on syntax and semantic level fault injections, a hybrid fault injection model is presented. To analyze the injected faults, the difficulty to inject (DTI) and difficulty to detect (DTD) are introduced and are measured from the programs used in the code-based experiment. Three interesting results were obtained from the experiments: 1) Failures simulated by the PIE model without consideration of the program and testing features are unreliably predicted; 2) There is no obvious correlation between the DTI and DTD parameters; 3) The DTD for syntax level faults changes in a different pattern to that for semantic level faults when the DTI increases. The results show that the parameters have a strong effect on the failures simulated, and the measurement of DTD is not strict.

  16. Field testing the prototype BNL fan-atomized oil burner

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, R.; Celebi, Y. [Brookhaven National Lab., Upton, NY (United States)

    1995-04-01

    BNL has developed a new oil burner design referred to as the Fan Atomized burner System. The primary objective of the field study was to evaluate and demonstrate the reliable operation of the Fan Atomized Burner. The secondary objective was to establish and validate the ability of a low firing rate burner (0.3-0.4 gph) to fully satisfy the heating and domestic hot water load demands of an average household in a climate zone with over 5,000 heating-degree-days. The field activity was also used to evaluate the practicality of side-wall venting with the Fan Atomized Burner with a low stack temperature (300F) and illustrate the potential for very high efficiency with an integrated heating system approach based on the Fan Atomized Burner.

  17. The evaluation of diagnostic tests for sexually transmitted infections

    OpenAIRE

    Chernesky, Max A.

    2005-01-01

    Diagnostic tests should receive method- and use-effectiveness evaluations. Method-effectiveness evaluations determine sensitivity, specificity and predictive values for new tests. Use-effectiveness evaluations determine how practical or convenient a new test will be in a specific setting and may not be performed in a formal way in North American laboratories. To perform a clinical method evaluation of diagnostic tests, a good relationship between laboratory and clinical personnel is essential...

  18. Field Test of Wake Steering at an Offshore Wind Farm

    Energy Technology Data Exchange (ETDEWEB)

    Fleming, Paul; Annoni, Jennifer; Shah, Jigar J.; Wang, Linpeng; Ananthan, Shreyas; Zhang, Zhijun; Hutchings, Kyle; Wang, Peng; Chen, Weiguo; Chen, Lin

    2017-02-06

    In this paper, a field test of wake steering control is presented. The field test is the result of a collaboration between the National Renewable Energy Laboratory (NREL) and Envision Energy, a smart energy management company and turbine manufacturer. In the campaign, an array of turbines within an operating commercial offshore wind farm in China have the normal yaw controller modified to implement wake steering according to a yaw control strategy. The strategy was designed using NREL wind farm models, including a computational fluid dynamics model, SOWFA, for understanding wake dynamics and an engineering model, FLORIS, for yaw control optimization. Results indicate that, within the certainty afforded by the data, the wake-steering controller was successful in increasing power capture, by amounts similar to those predicted from the models.

  19. The virtual fields method applied to spalling tests on concrete

    Directory of Open Access Journals (Sweden)

    Forquin P.

    2012-08-01

    Full Text Available For one decade spalling techniques based on the use of a metallic Hopkinson bar put in contact with a concrete sample have been widely employed to characterize the dynamic tensile strength of concrete at strain-rates ranging from a few tens to two hundreds of s−1. However, the processing method mainly based on the use of the velocity profile measured on the rear free surface of the sample (Novikov formula remains quite basic and an identification of the whole softening behaviour of the concrete is out of reach. In the present paper a new processing method is proposed based on the use of the Virtual Fields Method (VFM. First, a digital high speed camera is used to record the pictures of a grid glued on the specimen. Next, full-field measurements are used to obtain the axial displacement field at the surface of the specimen. Finally, a specific virtual field has been defined in the VFM equation to use the acceleration map as an alternative ‘load cell’. This method applied to three spalling tests allowed to identify Young’s modulus during the test. It was shown that this modulus is constant during the initial compressive part of the test and decreases in the tensile part when micro-damage exists. It was also shown that in such a simple inertial test, it was possible to reconstruct average axial stress profiles using only the acceleration data. Then, it was possible to construct local stress-strain curves and derive a tensile strength value.

  20. 30 CFR 15.3 - Observers at tests and evaluation.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Observers at tests and evaluation. 15.3 Section 15.3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION... General Provisions § 15.3 Observers at tests and evaluation. Only personnel of MSHA, designees of...

  1. Field-testing UV disinfection of drinking water

    Energy Technology Data Exchange (ETDEWEB)

    Gadgil, A.; Drescher, A.; Greene, D. [Lawrence Berkeley National Lab., CA (United States); Miller, P. [Natural Resources Defense Council (United States); Motau, C. [South African Center for Essential Community Services (South Africa); Stevens, F. [Durban Metro Water (South Africa)

    1997-09-01

    A recently invented device, ``UV Waterworks,`` uses ultraviolet (UV) light to disinfect drinking water. Its novel features are: low cost, robust design, rapid disinfection, low electricity use, low maintenance, high flow rate and ability to work with unpressurized water sources. The device could service a community of 1,000 persons, at an annual total cost of less than 10 US cents per person. UV Waterworks has been successfully tested in the laboratory. Limited field trials of an early version of the device were conducted in India in 1994--95. Insights from these trials led to the present design. Extended field trials of UV Waterworks, initiated in South Africa in February 1997, will be coordinated by the South African Center for Essential Community Services (SACECS), with technical and organizational support from Lawrence Berkeley National Laboratory(LBNL) and the Natural Resources Defense Council (both US). The first of the eight planned sites of the year long trial is an AIDS hospice near Durban. Durban metro Water and LBNL lab-tested a UV Waterworks unit prior to installing it at the hospice in August, 1997. The authors describe the field test plans and preliminary results from Durban.

  2. Stellar Systems Inc. Series 800/5000 E-Field sensor evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Follis, R.L.

    1990-08-01

    This report concerns the evaluation of the Stellar Systems Inc. E-Field intrusion detection system Series 800 control unit and the 5000 Series hardware components. Included are functional descriptions, installation procedures, testing procedures, and testing/operational results. 35 figs.

  3. Biplot evaluation of test environments and identification of mega-environments for sugarcane cultivars in China

    Science.gov (United States)

    Evaluation of test environments and classification of regional ecological zones are the two key issues in regional testing of sugarcane cultivars. In the present study, sugarcane yield data from a three-year nationwide field trial involving 21 cultivars and 14 pilot test locations were analyzed by u...

  4. Technical Evaluation of Oak Ridge Filter Test Facility

    CERN Document Server

    Kriskovich, J R

    2002-01-01

    Two evaluations of the Oak Ridge Department of Energy (DOE) Filter Test Facility (FTF) were performed on December 11 and 12, 2001, and consisted of a quality assurance and a technical evaluation. This report documents results of the technical evaluation.

  5. Razor UAS Test and Evaluation System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Adsys Controls' Razor UAS Test System is a high fidelity simulation and Hardware-in-the-Loop (HIL) test system. Razor provides extensive existing capability for high...

  6. An Evaluation of the IELTS Speaking Test

    Institute of Scientific and Technical Information of China (English)

    戈国梁

    2014-01-01

    This paper analyzes the characteristics of the IELTS Speaking Test against the requirements for effective testing in Bachman and Palmer’s (1996) test usefulness framework, which include the six qualities of reliability, validity, authenticity, inter-activeness, practicality and impact. In particular, it examines the test on criteria including fluency and coherence;lexical resource;grammatical range and accuracy;and pronunciation (IETLS official website). It includes a judgment about its value.

  7. The Evaluation of BEC Vantage (Oral Test)

    Institute of Scientific and Technical Information of China (English)

    昌根花; 廖海红

    2012-01-01

      The validity and reliability of BEC Vantage are the key factors to the success and failure of oral test. This paper evalu⁃ates the speaking test of BEC Vantage by analyzing the reliability, authenticity, validity and the assessment of the test.

  8. Design and Installation of a Disposal Cell Cover Field Test

    Energy Technology Data Exchange (ETDEWEB)

    Benson, C.H. [University of Wisconsin–Madison, Madison, Wisconsin; Waugh, W.J. [S.M. Stoller Corporation, Grand Junction, Colorado; Albright, W.H. [Desert Research Institute, Reno, Nevada; Smith, G.M. [Geo-Smith Engineering, Grand Junction, Colorado; Bush, R.P. [U.S. Department of Energy, Grand Junction, Colorado

    2011-02-27

    The U.S. Department of Energy’s Office of Legacy Management (LM) initiated a cover assessment project in September 2007 to evaluate an inexpensive approach to enhancing the hydrological performance of final covers for disposal cells. The objective is to accelerate and enhance natural processes that are transforming existing conventional covers, which rely on low-conductivity earthen barriers, into water balance covers, that store water in soil and release it as soil evaporation and plant transpiration. A low conductivity cover could be modified by deliberately blending the upper layers of the cover profile and planting native shrubs. A test facility was constructed at the Grand Junction, Colorado, Disposal Site to evaluate the proposed methodology. The test cover was constructed in two identical sections, each including a large drainage lysimeter. The test cover was constructed with the same design and using the same materials as the existing disposal cell in order to allow for a direct comparison of performance. One test section will be renovated using the proposed method; the other is a control. LM is using the lysimeters to evaluate the effectiveness of the renovation treatment by monitoring hydrologic conditions within the cover profile as well as all water entering and leaving the system. This paper describes the historical experience of final covers employing earthen barrier layers, the design and operation of the lysimeter test facility, testing conducted to characterize the as-built engineering and edaphic properties of the lysimeter soils, the calibration of instruments installed at the test facility, and monitoring data collected since the lysimeters were constructed.

  9. Relationships Between Anaerobic Performance, Field Tests and Game Performance of Sitting Volleyball Players

    Directory of Open Access Journals (Sweden)

    Marszalek Jolanta

    2015-12-01

    Full Text Available The aim of this study was to evaluate relationships between anaerobic performance, field tests, game performance and anthropometric variables of sitting volleyball players. Twenty elite Polish sitting volleyball players were tested using the 30 s Wingate Anaerobic Test for arm crank ergometer and participated in six physical field tests. Heights in position to block and to spike, as well as arm reach were measured. Players were observed during the game on the court in terms of effectiveness of the serve, block, attack, receive and defense. Pearson analysis and the Spearman's rank correlation coefficient were used. The strongest correlations were found between the chest pass test and mean power and peak power (r=.846; p=.001 and r=.708; p=.0005, respectively, and also between the T-test and peak power (r= −.718; p=.001. Mean power correlated with the 3 m test (r= −.540; p=.014, the 5 m test (r= −.592; p=.006, and the T-test (r= −.582; p=.007. Peak power correlated with the 3 m test (r= −.632; p=.003, the 5 m test (r= −.613; p=.004, speed & agility (r= −.552; p=.012 and speed & endurance (r=−.546; p=.013. Significant correlations were observed between anthropometric parameters and anaerobic performance variables (p≤.001, and also between anthropometric parameters and field tests (p≤.05. Game performance and physical fitness of sitting volleyball players depended on their anthropometric variables: reach of arms, the position to block and to spike. The chest pass test could be used as a non-laboratory field test of anaerobic performance of sitting volleyball players.

  10. Deep Borehole Field Test Requirements and Controlled Assumptions.

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Ernest [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-07-01

    This document presents design requirements and controlled assumptions intended for use in the engineering development and testing of: 1) prototype packages for radioactive waste disposal in deep boreholes; 2) a waste package surface handling system; and 3) a subsurface system for emplacing and retrieving packages in deep boreholes. Engineering development and testing is being performed as part of the Deep Borehole Field Test (DBFT; SNL 2014a). This document presents parallel sets of requirements for a waste disposal system and for the DBFT, showing the close relationship. In addition to design, it will also inform planning for drilling, construction, and scientific characterization activities for the DBFT. The information presented here follows typical preparations for engineering design. It includes functional and operating requirements for handling and emplacement/retrieval equipment, waste package design and emplacement requirements, borehole construction requirements, sealing requirements, and performance criteria. Assumptions are included where they could impact engineering design. Design solutions are avoided in the requirements discussion. Deep Borehole Field Test Requirements and Controlled Assumptions July 21, 2015 iv ACKNOWLEDGEMENTS This set of requirements and assumptions has benefited greatly from reviews by Gordon Appel, Geoff Freeze, Kris Kuhlman, Bob MacKinnon, Steve Pye, David Sassani, Dave Sevougian, and Jiann Su.

  11. Estimation of the level of anxiety in rats: differences in results of open-field test, elevated plus-maze test, and Vogel's conflict test.

    Science.gov (United States)

    Sudakov, S K; Nazarova, G A; Alekseeva, E V; Bashkatova, V G

    2013-07-01

    We compared individual anxiety assessed by three standard tests, open-field test, elevated plus-maze test, and Vogel conflict drinking test, in the same animals. No significant correlations between the main anxiety parameters were found in these three experimental models. Groups of animals with high and low anxiety rats were formed by a single parameter and subsequent selection of two extreme groups (10%). It was found that none of the tests could be used for reliable estimation of individual anxiety in rats. The individual anxiety level with high degree of confidence was determined in high-anxiety and low-anxiety rats demonstrating behavioral parameters above and below the mean values in all tests used. Therefore, several tests should be used for evaluation of the individual anxiety or sensitivity to emotional stress.

  12. Standard Guide for Conducting Corrosion Tests in Field Applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide covers procedures for conducting corrosion tests in plant equipment or systems under operating conditions to evaluate the corrosion resistance of engineering materials. It does not cover electrochemical methods for determining corrosion rates. 1.1.1 While intended primarily for immersion tests, general guidelines provided can be applicable for exposure of test specimens in plant atmospheres, provided that placement and orientation of the test specimens is non-restrictive to air circulation. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See also 10.4.2.

  13. Simple and rapid field tests for brucellosis in livestock.

    Science.gov (United States)

    Abdoel, Theresia; Dias, Isabel Travassos; Cardoso, Regina; Smits, Henk L

    2008-08-25

    Four simple and rapid field tests for the serodiagnosis of brucellosis in cattle, goat, sheep and swine were developed. The performance of the assays was investigated using serum samples collected in Portugal from animals originating from herds with a defined sanitary status with respect to the presence of brucellosis. The sensitivity calculated for the bovine, caprine, ovine and swine Brucella lateral flow assays based on results obtained for samples collected from animals with culture confirmed brucellosis was 90%, 100%, 90% and 73%, respectively. None of the samples from animals from herds free of brucellosis reacted in the flow assays indicating a high specificity. However, as expected, some degree of reactivity was observed when testing selected serum samples that reacted non-specific in reference tests for brucellosis.

  14. Field Testing of a 1/100th Scale Starshade

    Science.gov (United States)

    Casement, L. S.; Glassman, T. M.; Lo, A.; Warwick, S.; Armagan, O.

    2013-01-01

    The external starshade is a prospective method for the direct detection and spectral characterization of terrestrial planets around other stars, a key goal identified in ASTRO2010. Validation of this approach has been challenging at ~1/1000th scale in the lab (Samuele et al., 2010). Recently we have successfully fabricated 60 cm 1/100th scale) starshades and have begun a series of ground test experiments with them. Our first experiment, limited by city lights and a short (300 m) baseline between the telescope and the starshade, showed excellent light suppression of >106. We enhanced our experimental setup to provide longer baselines and reduced aperture size to provide a closer match to the Fresnel number expected for the flight system. We took our test equipment into the field for a test in November 2012, the results of which are presented here.

  15. Testing strong-field CED and QED with intense laser fields

    Energy Technology Data Exchange (ETDEWEB)

    Piazza, Antonino di; Hatsagortsyan, Karen Z.; King, Ben; Keitel, Christoph H. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany)

    2010-07-01

    Strong laser fields can be employed to test classical and quantum electrodynamics (CED and QED, respectively) under extreme conditions. A fundamental problem in electrodynamics is the ''radiation reaction'' problem: classically, an accelerated electron emits radiation and this emission alters the motion of the electron itself. The Landau-Lifshitz equation consistently describes the electron's motion in an external field by including radiation reaction. We explore a new scenario in which this equation can be in principle tested experimentally for the first time and with presently available laser technology. We will also briefly address quantum vacuum polarization effects. We demonstrate the possibility of observing electron-positron pair production in laser and nuclear fields, by controlling the tunneling barrier through the assistance of an additional high-energy photon. Finally, by exploiting the quantum interaction among real photon in vacuum, we propose a double-slit-like experiment devoid of any material parts.

  16. Field Test of Expedient Pavement Repairs (Test Items 16-35).

    Science.gov (United States)

    1980-11-01

    7 AD-AlG 903 A IR FORCE ENGINEERING AND SERVICES CENTER TYNDALL AF--ETC FG 13/2 FIELD TEST OF EXPEDIENT PAVEMENT REPAIRS ( TEST ITEMS 16-35).(U...PAVEMENT REPAIRS ~( TEST ITEMS 16-35) MICHAEL T. McNERNEY ENGINEERING RESEARCH DIVISION NOVEMBER 1980 ’ FINAL REPORT JULY 1978 - SEPTEMBER 1979 APPROVED FOR...EXPEDIENT PAVEMENT REPAIRS Final Reportg- July 1978- ( TEST ITEMS 16-35), Segtr W79 7. "AUTHOR(s) 8 CONTRACT OR GRANT NUMBER(s) Michael T./lcNernev, P

  17. Evaluation of the 1st DIGIT field trial

    OpenAIRE

    Lund, Mass Soldal; Bogya, Emese Lujza

    2008-01-01

    This report evaluates the 1st DIGIT field trial, a security risk analysis conducted for Santander in the autumn of 2007. The evaluation includes lessons learned from the analysis and an empirical investigation into the use of the CORAS language in the analysis.

  18. 40 CFR 63.5850 - How do I conduct performance tests, performance evaluations, and design evaluations?

    Science.gov (United States)

    2010-07-01

    ... test, performance evaluation, and design evaluation in 40 CFR part 63, subpart SS, that applies to you..., performance evaluations, and design evaluations? 63.5850 Section 63.5850 Protection of Environment... conduct performance tests, performance evaluations, and design evaluations? (a) If you are using any...

  19. Special ESP configurations designed to test and produce Yemen oil field. [Electric-Submersible Pump

    Energy Technology Data Exchange (ETDEWEB)

    Wilkie, D.I. (Canadian Occidental Petroleum Ltd., Calgary, Alberta (Canada))

    1993-09-27

    Innovative electric-submersible-pump (ESP) configurations were used in the exploration phase of a Yemen oil field discovered by Canadian Occidental Petroleum Ltd. Because of subnormal reservoir pressure, CanOxy developed the field with ESPs and had to install surface components that could operate at the high, 130 F., ambient temperatures common in Yemen. The field is in a remote area that has seen very little development. The reservoirs produce a medium-to-heavy crude with a low gas/oil ratio, typically less than 20 scf/bbl. Problems faced in evaluating the field included drilling through unconsolidated sands with high flow capacity and subnormal reservoir pressure. CanOxy had to develop the technology to test the wells during the exploration phase, and intends to use new, or at least uncommon technology, for producing the wells. The paper describes testing the wells, the electric generators and variable speed drives, and the use of these pumps on production wells.

  20. Visual Field Testing with Head-Mounted Perimeter ‘imo’

    Science.gov (United States)

    Matsumoto, Chota; Yamao, Sayaka; Nomoto, Hiroki; Takada, Sonoko; Okuyama, Sachiko; Kimura, Shinji; Yamanaka, Kenzo; Aihara, Makoto; Shimomura, Yoshikazu

    2016-01-01

    Purpose We developed a new portable head-mounted perimeter, “imo”, which performs visual field (VF) testing under flexible conditions without a dark room. Besides the monocular eye test, imo can present a test target randomly to either eye without occlusion (a binocular random single eye test). The performance of imo was evaluated. Methods Using full HD transmissive LCD and high intensity LED backlights, imo can display a test target under the same test conditions as the Humphrey Field Analyzer (HFA). The monocular and binocular random single eye tests by imo and the HFA test were performed on 40 eyes of 20 subjects with glaucoma. VF sensitivity results by the monocular and binocular random single eye tests were compared, and these test results were further compared to those by the HFA. The subjects were asked whether they noticed which eye was being tested during the test. Results The mean sensitivity (MS) obtained with the HFA highly correlated with the MS by the imo monocular test (R: r = 0.96, L: r = 0.94, P < 0.001) and the binocular random single eye test (R: r = 0.97, L: r = 0.98, P < 0.001). The MS values by the monocular and binocular random single eye tests also highly correlated (R: r = 0.96, L: r = 0.95, P < 0.001). No subject could detect which eye was being tested during the examination. Conclusions The perimeter imo can obtain VF sensitivity highly compatible to that by the standard automated perimeter. The binocular random single eye test provides a non-occlusion test condition without the examinee being aware of the tested eye. PMID:27564382

  1. High temperature superconducting axial field magnetic coupler: realization and test

    Science.gov (United States)

    Belguerras, L.; Mezani, S.; Lubin, T.; Lévêque, J.; Rezzoug, A.

    2015-09-01

    Contactless torque transmission through a large airgap is required in some industrial applications in which hermetic isolation is necessary. This torque transmission usually uses magnetic couplers, whose dimension strongly depends on the airgap flux density. The use of high temperature superconducting (HTS) coils to create a strong magnetic field may constitute a solution to reduce the size of the coupler. It is also possible to use this coupler to replace a torque tube in transmitting the torque produced by a HTS motor to its load. This paper presents the detailed construction and tests of an axial field HTS magnetic coupler. Pancake coils have been manufactured from BSCCO tape and used in one rotor of the coupler. The second rotor is mainly composed of NdFeB permanent magnets. Several tests have been carried out showing that the constructed coupler is working properly. A 3D finite element (FE) model of the studied coupler has been developed. Airgap magnetic field and torque measurements have been carried out and compared to the FE results. It has been shown that the measured and the computed quantities are in satisfactory agreement.

  2. Field Measurements and Pullout Tests of Reinforced Earth Retaining Wall

    Institute of Scientific and Technical Information of China (English)

    陈群; 何昌荣; 朱分清

    2004-01-01

    In this paper, field measurements and pullout tests of a new type of reinforced earth retaining wall, which is reinforced by trapezoid concrete blocks connected by steel bar, are described. Field measurements included settlements of the earth fill, tensile forces in the ties and earth pressures on the facing panels during the construction and at completion. Based on the measurements, the following statements can be made: ( 1 ) the tensile forces in the ties increased with the height of backfill above the tie and there is a tensile force crest in most ties; (2) at completion, the measured earth pressures along the wall face were between the values of the active earth pressures and the pressures at rest; (3) larger settlements occurred near the face of the wall where a zone of drainage sand and gravel was not compacted properly and smaller settlements occurred in the well-compacted backfill. The results of field pullout tests indicated that the magnitudes of pullout resistances as well as tensile forces induced in the ties were strongly influenced by the relative displacements between the ties and the backfill, and pullout resistances increased with the height of backfill above the ties and the length of ties.

  3. Radionuclide observables during the Integrated Field Exercise of the Comprehensive Nuclear-Test-Ban Treaty

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, Jonathan L.; Miley, Harry S.; Milbrath, Brian D.

    2016-03-01

    In 2014 the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) undertook the Integrated Field Exercise (IFE) in Jordan. The exercise consisted of a simulated 0.5 – 2 kT underground explosion triggering an On-site Inspection (OSI) to search for evidence of a Treaty violation. This research evaluates two of the OSI techniques, including laboratory-based gamma-spectrometry of soil samples and in situ gamma-spectrometry for 17 particulate radionuclides indicative of nuclear weapon tests. The detection sensitivity is evaluated using real IFE and model data. It indicates that higher sensitivity laboratory measurements are the optimum technique during the IFE and OSI timeframes.

  4. Relation of field independence and test-item format to student performance on written piagetian tests

    Science.gov (United States)

    Ló; Pez-Rupérez, F.; Palacios, C.; Sanchez, J.

    In this study we have investigated the relationship between the field-dependence-independence (FDI) dimension as measured by the Group Embedded Figures Test (GEFT) and subject performance on the Longeot test, a pencil-and-paper Piagetian test, through the open or closed format of its items. The sample consisted of 141 high school students. Correlation and variance analysis show that the FDI dimension and GEFT correlate significantly on only those items on the Longeot test that require formal reasoning. The effect of open- or closed-item format is found exclusively for formal items; only the open format discriminates significantly (at the 0.01 level) between the field-dependent and -independent subjects performing on this type of item. Some implications of these results for science education are discussed.

  5. Field tests of 2- and 40-tube condensers at the East Mesa Geothermal Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, R.W.; Domingo, N.

    1982-05-01

    Two water-cooled isobutane condensers, one with 2 tubes and one with 40 tubes, were subjected to field tests at the East Mesa Geothermal Test Site to assess relative heat transfer performance in both surface evaporator and direct-contact evaporator modes. The five groups of tests established that field performance was below earlier laboratory-determined levels and that direct-contact evaporator mode performance was poorer than that for the surface evaporator mode. In all test situations, fluted condenser tubes performed better than smooth condenser tubes. Cooling water quality had no significant effect on performance, but brine preflash in the direct-contact mode did promote some relative performance improvement. Important implications of these results for binary geothermal power plants are that (1) working-fluid-side impurities can significantly degrade heat transfer performance of the power plant condensers and (2) provisions for minimizing such impurities may be required.

  6. A Method for Evaluating the Magnetic Field Homogeneity of a Radiofrequency Coil by Its Field Histogram

    Science.gov (United States)

    Yang, Q. X.; Li, S. H.; Smith, M. B.

    The magnetic field homogeneity of a radiofrequency coil is very important in both magnetic resonance imaging and spectroscopy. In this report, a method is proposed for quantitatively evaluating the RF magnetic field homogeneity from its histogram, which is obtained by either experimental measurement or theoretical calculation. The experimental histogram and theoretical histogram can be compared directly to verify the theoretical findings. The RF field homogeneities of the bird-cage coil, slotted-tube resonator, cosine wire coil, and a new radial plate coil design were evaluated using this method. The results showed that the experimental histograms and the corresponding theoretical histograms are consistent. This method provides an easy and sensitive way of evaluating the magnetic field homogeneity and facilitates the design and evaluation of new RF coil configurations.

  7. Field evaluation of the effectiveness of engineered soil covers for reactive tailings

    Energy Technology Data Exchange (ETDEWEB)

    Yanful, E.K.; Woyshner, M.R.; Aube, B.C.

    1993-10-01

    The purpose is to design, construct, and evaluate the effectiveness of soil covers and a geomembrane, or plastic cover, to reduce acid generation in reactive mine tailings. The evaluation involves performance monitoring of field test plots at the decommissioned Waite Amulet tailings site and laboratory experiments. Gaseous oxygen concentrations, water content, suction, temperature, and pore water quality at various depths were measured at plots set up to test two soil covers, the geomembrane cover, and as a control. The results from the four tests are reported and evaluated. 43 refs., 98 figs., 27 tabs.

  8. Empirical Evaluation of Directional-Dependence Tests

    Science.gov (United States)

    Thoemmes, Felix

    2015-01-01

    Testing of directional dependence is a method to infer causal direction that recently has attracted some attention. Previous examples by e.g. von Eye and DeShon (2012a) and extensive simulation studies by Pornprasertmanit and Little (2012) have demonstrated that under specific assumptions, directional-dependence tests can recover the true causal…

  9. Evaluating Test Validity: Reprise and Progress

    Science.gov (United States)

    Shepard, Lorrie A.

    2016-01-01

    The AERA, APA, NCME Standards define validity as "the degree to which evidence and theory support the interpretations of test scores for proposed uses of tests". A century of disagreement about validity does not mean that there has not been substantial progress. This consensus definition brings together interpretations and use so that it…

  10. Minimum Competency Testing--Grading or Evaluation?

    Science.gov (United States)

    Prakash, Madhu Suri

    The consequences of the minimum competency testing movement may bring into question the basic assumptions, goals, and expectations of our school system. The intended use of these tests is the assessment of students; the unintended consequence may be the assessment of the school system. There are two ways in which schools may fail in the context of…

  11. TEST OF AN ANIMAL DRAWN FIELD IMPLEMENT CART

    Directory of Open Access Journals (Sweden)

    Paolo Spugnoli

    2008-06-01

    Full Text Available The field performance of a horse-drawn hitch cart equipped with a PTO system powered by the two cart ground wheels have been investigated. For this purpose field tests on clay and turf soil, with varying ballast and PTO torque, have been carried out pulling the cart by a tractor. Preliminary tests were aimed at assessing the traction capability of horse breed. These tests showed that the mean draught force given by two of these horses was 173daN, average working speed was about 1m*s-1, resulting a mean draught power developed by each horse of about 0.86kW. The PTO cart system performance has shown that the torque has not exceeded 2.4daN*m, maximum draught or PTO power was 1.15kW, rotation speed just higher than 400min-1, with mean efficiency of about 50%. These values are consistent with horse performance and small haymaking, fertilizing, seeding and chemical application machine requirements.

  12. Detailed field test of yaw-based wake steering

    Science.gov (United States)

    Fleming, P.; Churchfield, M.; Scholbrock, A.; Clifton, A.; Schreck, S.; Johnson, K.; Wright, A.; Gebraad, P.; Annoni, J.; Naughton, B.; Berg, J.; Herges, T.; White, J.; Mikkelsen, T.; Sjöholm, M.; Angelou, N.

    2016-09-01

    This paper describes a detailed field-test campaign to investigate yaw-based wake steering. In yaw-based wake steering, an upstream turbine intentionally misaligns its yaw with respect to the inflow to deflect its wake away from a downstream turbine, with the goal of increasing total power production. In the first phase, a nacelle-mounted scanning lidar was used to verify wake deflection of a misaligned turbine and calibrate wake deflection models. In the second phase, these models were used within a yaw controller to achieve a desired wake deflection. This paper details the experimental design and setup. All data collected as part of this field experiment will be archived and made available to the public via the U.S. Department of Energy's Atmosphere to Electrons Data Archive and Portal.

  13. Fault detection by surface seismic scanning tunneling macroscope: Field test

    KAUST Repository

    Hanafy, Sherif M.

    2014-08-05

    The seismic scanning tunneling macroscope (SSTM) is proposed for detecting the presence of near-surface impedance anomalies and faults. Results with synthetic data are consistent with theory in that scatterers closer to the surface provide brighter SSTM profiles than those that are deeper. The SSTM profiles show superresolution detection if the scatterers are in the near-field region of the recording line. The field data tests near Gulf of Aqaba, Haql, KSA clearly show the presence of the observable fault scarp, and identify the subsurface presence of the hidden faults indicated in the tomograms. Superresolution detection of the fault is achieved, even when the 35 Hz data are lowpass filtered to the 5-10 Hz band.

  14. Field tests on landfill covers for evaluation of performance of mineral cover systems%垃圾填埋场覆盖层现场试验及特性评价

    Institute of Scientific and Technical Information of China (English)

    GARTUNG; Erwin; HENKEN-MELLIES; Ulrich; RAMKE; Hans-Giinter; 胡一峰

    2006-01-01

    Cover systems consist of soil layers with different properties and different functions. They are exposed to the atmosphere and to vegetation. The water content of the soils varies with seasons and weather conditions. In winter, the degree of saturation of the soils increases, and in summer the water content is reduced while the matric suction increases. If the matric suction in the compacted clay layer exceeds a limiting value, desiccation cracks occur, and the sealing function is impeded. In order to examine the performance of mineral cover systems, two large scale test fields were installed with different thickness of the restoration profile. Preliminary results of these investigations were presented including data of water flow, matric suction and soil temperature. The role of the restoration profile for the water balance of the cover systems was focussed on.%填埋场覆盖系统由不同的土层组成,它们具有不同的性质和功能.覆盖层直接与大气和植被接触,因此土的含水率随季节和天气条件不断变化.冬天,土的饱和度增加.夏天,土的含水率减少,同时土中吸力增加.如果土中吸力达到某个极限值,将出现干缩裂缝.这时,粘土阻隔层的密封功能将受到损害.为了研究粘土覆盖系统的长期性状,我们进行了两个大规模现场试验.本文介绍第一批现场试验结果,包括水流量、土中吸力和温度的变化规律.重点介绍保护层(营养层)厚度对覆盖系统水平衡的影响.

  15. Test plan for FY-94 digface characterization field experiments

    Energy Technology Data Exchange (ETDEWEB)

    Josten, N.E.; Roybal, L.G.

    1994-08-01

    The digface characterization concept has been under development at the Idaho National Engineering Laboratory (INEL) since fiscal year (FY) 1992 through the support of the Buried Waste Integrated Demonstration Program. A digface characterization system conducts continuous subsurface characterization simultaneously with retrieval of hazardous and radioactive waste from buried waste sites. The system deploys multiple sensors at the retrieval operation digface and collects data that provide a basis for detecting, locating, and classifying buried materials and hazardous conditions before they are disturbed by the retrieval equipment. This test plan describes ongoing efforts to test the digface characterization concept at the INEL`s Cold Test Pit using a simplified prototype deployment apparatus and off-the-shelf sensors. FY-94 field experiments will explore problems in object detection and classification. Detection and classification of objects are fundamental to three of the four primary functions of digface characterization during overburden removal. This test plan establishes procedures for collecting and validating the digface characterization data sets. Analysis of these data will focus on testing and further developing analysis methods for object detection and classification during overburden removal.

  16. Validity of Selected Lab and Field Tests of Physical Working Capacity.

    Science.gov (United States)

    Burke, Edmund J.

    The validity of selected lab and field tests of physical working capacity was investigated. Forty-four male college students were administered a series of lab and field tests of physical working capacity. Lab tests include a test of maximum oxygen uptake, the PWC 170 test, the Harvard Step Test, the Progressive Pulse Ratio Test, Margaria Test of…

  17. Detailed Test Plan Redundant Sensor Strapdown IMU Evaluation Program

    Science.gov (United States)

    Hartwell, T.; Miyatake, Y.; Wedekind, D. E.

    1971-01-01

    The test plan for a redundant sensor strapdown inertial measuring unit evaluation program is presented. The subjects discussed are: (1) test philosophy and limitations, (2) test sequence, (3) equipment specifications, (4) general operating procedures, (5) calibration procedures, (6) alignment test phase, and (7) navigation test phase. The data and analysis requirements are analyzed.

  18. A survey and evaluation of lantern tests of color vision.

    Science.gov (United States)

    Cole, B L; Vingrys, A J

    1982-04-01

    This paper reports a survey of the lantern tests that have been or are used to evaluate the color vision of people who wish to enter occupations that require the ability to recognize colored signal lights reliably. The origin of each lantern is traced and the principal features of each are described. The available data concerning failure rate of normals, the failure rate of people with defective color vision, and the extent to which scores on lantern tests correlate with field trials are summarized. Despite the fact that lantern tests have been used since the turn of the century and that some lanterns have been in use for more than 30 years and some for much longer periods, the available validation data are incomplete and sometimes conflicting. However, the data do indicate that some lanterns may fail a significant proportion of normals and that there is considerable variation between lanterns in the proportion of color vision defectives that will fail. It is noted that most lanterns will pass some protanomals despite their reduced sensitivity to red light and correspondingly short visual range for red signals. The view of Cameron is supported that a more rational approach would be to made a clinical diagnosis of the type of color vision defect, to reject protanopes, deuteranopes, and protanomals and to use a lantern test only to determine which deuteranomals should be accepted.

  19. Preliminary operational results of the industrial process heat field tests

    Energy Technology Data Exchange (ETDEWEB)

    Kutscher, C.; Davenport, R.

    1980-04-01

    There are currently six DOE-funded solar industrial process heat (IPH) field tests which have been operational for one year or longer. These are all low temperature first generation projects which supply heat at temperatures below 100/sup 0/C - three hot water and three hot air. During the 1979 calendar year, personnel from the Solar Energy Research Institute (SERI) visited all of these sites; the performance and cost results obtained for each project and the operational problems encountered at each site are discussed.

  20. Pulsed mixed n, {gamma} radiation fields for electronic testing

    Energy Technology Data Exchange (ETDEWEB)

    Nurdin, G.; Becret, C.; Jaureguy, J.C. [Etablissement Technique Central de l`Armement (ETCA), 94 - Arcueil (France); Vie, M.; Baboulet, J.P.; Lapeyre, P.; Ramisse, D. [D.G.A., 46 - Gramat (France)

    1994-12-31

    For combined n, {gamma} TREE testing we have modified the CALIBAN Fast Burst Reactor Field with CdO/Epoxy converters to cover the range [10{sup 11} -10{sup 12}] n.cm{sup -2} (1 MeV Si), [10{sup 7} - 10{sup 8}] cGy(Si).s{sup -1}. Activation and fission {sigma} {phi}vector, 1 MeV(Si) fluences, neutron spectra, total exposures and dose rates were predicted with good agreement by n, {gamma} photon transport codes. (author). 12 refs., 2 figs., 1 tab.

  1. Detailed field test of yaw-based wake steering

    DEFF Research Database (Denmark)

    Fleming, P.; Churchfield, M.; Scholbrock, A.

    2016-01-01

    This paper describes a detailed field-test campaign to investigate yaw-based wake steering. In yaw-based wake steering, an upstream turbine intentionally misaligns its yaw with respect to the inflow to deflect its wake away from a downstream turbine, with the goal of increasing total power...... production. In the first phase, a nacelle-mounted scanning lidar was used to verify wake deflection of a misaligned turbine and calibrate wake deflection models. In the second phase, these models were used within a yaw controller to achieve a desired wake deflection. This paper details the experimental...

  2. University of Minnesota Aquifer Thermal Energy Storage Field Test Facility

    Science.gov (United States)

    Walton, M.; Hoyer, M. C.

    1982-12-01

    The University of Minnesota Aquifer Thermal Energy Storage (ATES) Field Test Facility became operational. Experiments demonstrated that the Franconia-Ironton-Galesville aquifer will accept injection of 300 gpm (18.9 1 sec (-1)) at reasonable pressures with a heat buildup in the injection well of about 44 psi (31.6 m) over 8 days. Heating of the ground water caused precipitation of carbonate in the piping and injection well, but with proper water conditioning, the system will work satisfactorily at elevated temperatures.

  3. Field Test: Results from the One Year Mission

    Science.gov (United States)

    Reschke, M. F.; Kozlovskaya, I. B.; Kofman, I. S.; Tomilovskaya, E. S.; Cerisano, J. M.; Rosenberg, M. J. F.; Bloomberg, J. J.; Stenger, M. B.; Lee, S. M. C.; Laurie, S. S.; Rukavishnikov, I. V.; Fomina, E. V.; Wood, S. J.; Mulavara, A. P.; Feiveson, A. H.; Fisher, E. A.; Phillips, T.; Ribeiro, C.; Taylor, L. C.; Miller, C. A.; Gadd, N. E.; Peters, B. T.; Kitov, V. V.; Lysova, N. Yu; Holden, K. L.; De Dios, Y.

    2017-01-01

    The One Year Mission was designed to aid in determining the effect that extending the duration on orbit aboard the International Space Station (ISS) would have on a number of biological and physiological systems. Two crewmembers were selected to participate in this endeavor, one U.S. On-Orbit Segment (USOS) astronaut and one Russian cosmonaut. The Neuroscience and Cardiovascular and Vision Laboratories at the Johnson Space Center and the Sensory-Motor and Countermeasures Division within the Institute for Biomedical Problems were selected to investigate vestibular, sensorimotor and cardiovascular function with the two long-duration crewmembers using the established methodology developed for the Field Test (FT).

  4. Application of GPS and Near-Surface Geophysical Methods to Evaluate Agricultural Test Plot Differences

    Science.gov (United States)

    A field research facility with two pairs of replicated agricultural test plots (four total) was established at a location in northwest Ohio during 2005 for the purpose of studying water table management strategies. Initial efforts at this field research facility were devoted to evaluating difference...

  5. SDU6 Interior Liner Testing & Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Skidmore, T. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-10-14

    Two liner materials (Marseal® M-3500 and REMA Chemoline® 4CN) proposed for use as a liner inside the Saltstone Disposal Unit 6 (SDU6) were subjected to specific ASTM tests (tensile and lap-shear) after immersion in 50% and 100% simulant solutions for 1000 hours at the Savannah River Ecology Laboratory. Both liner materials exhibited good resistance to the simulant chemistry, at least based on the tests performed and the test duration/conditions imposed. In lap-shear tests, both materials failed in the base material rather than peeling apart, confirming good adhesion. The REMA 4CN bromobutyl elastomer showed superior bonding characteristics and absence of warping or delamination at the conditions tested. The Marseal M-3500 material (PVC/EVA blend with polyester reinforcement) exhibited deformation and debonding in some locations. The cause of the deformation and delamination observed in the Marseal M-3500 material is not fully known, but possibly attributed to thermomechanical stress at immersion temperatures, and the thermoplastic nature of the material. The immersion temperature (68 °C) is slightly greater than the maximum use temperature limit quoted for the Marseal M- 3500 liner (65 °C), though the basis for the service limit is unknown. The testing performed was limited in scope and only for these two liner materials. These tests were primarily performed to screen for severe incompatibility or short-term degradation in Saltstone bleedwater simulants at bounding solution temperatures. Additional testing is recommended to assess long-term performance and the overall service life of the liner.

  6. Hypersensitivity test to electric magnetic fields; Test de hipersensibilidad a exposiciones residenciales a campos magneticos

    Energy Technology Data Exchange (ETDEWEB)

    Ubeda Maeso, A.; Martinez Pascual, M. A.

    2004-07-01

    The so-called electromagnetic hypersensitivity (RH) syndrome includes a number of unspecific, medically unexplained symptoms attributed to exposure to electric and magnetic fields. As a whole, laboratory tests have provided inconclusive results, in part due to the fact that many individuals show nuclear, inconsistent responses to repeated experimental field-exposures. It has been proposed that such inconsistencies could be due in part to distress caused by the lab test itself. We have developed a test to be conducted at the patient's residence, allowing for long-term follow up of exposure-response assessment and avoiding the laboratory environment and the presence of the researcher as potential stressors and confounding factors. In a pilot test, EMDEX-II magnetometers were used to continuously recording power-frequency magnetic fields in the residence of a patient with perceived EH. The patient's symptoms included distress, headache and dizziness, among other ailments. Magnetographic data of a total of 123 recording days were plotted against the corresponding data on occurrence of the symptoms episodes. As a whole, the results did not show positive linear correlation between the daily occurrence of the episode and the exposures levels recorded during the day or during the day before. These preliminary results are little supportive of the hypothesis that the patient's ailments are caused or worsened by a putative hypersensitivity to residential exposure to power-frequency magnetic fields in the 0.02-4.00 {mu}T range. (Author) 29 refs.

  7. Field Evaluation of Advances in Energy-Efficiency Practices for Manufactured Homes

    Energy Technology Data Exchange (ETDEWEB)

    Levy, E. [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Dentz, J. [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Ansanelli, E. [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Barker, G. [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Rath, P. [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Dadia, D. [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States)

    2016-03-01

    Through field-testing and analysis, this project evaluated whole-building approaches and estimated the relative contributions of select technologies toward reducing energy use related to space conditioning in new manufactured homes. Three lab houses of varying designs were built and tested side-by-side under controlled conditions in Russellville, Alabama. The tests provided a valuable indicator of how changes in the construction of manufactured homes can contribute to significant reductions in energy use.

  8. Field tests of a tissue-equivalent beta survey meter

    Energy Technology Data Exchange (ETDEWEB)

    Martz, D.E.; Johnson, L.O.; Rich, B.L.; Daniel, S.H.

    1986-01-01

    A tissue-equivalent survey meter for monitoring the (dD/dt)(0.07) and (dD/dt)(10) dose rates produced by betas and photons has been designed and tested. The very thin tissue-equivalent plastic scintillator closely simulates the critical skin tissue layer between 4 mg.cm/sup -2/ and 9 mg.cm/sup -2/. The meter is calibrated to read the (dD/dt)(0.07) dose rate directly, and the (dD/dt)(10) dose rate behind a filter. Laboratory measurements of calibrated sources and field tests have demonstrated tissue-equivalent response of the survey meter to betas between 70 keV and 2500 keV and to photons with energies greater than about 30 keV.

  9. 30 CFR 14.3 - Observers at tests and evaluations.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Observers at tests and evaluations. 14.3 Section 14.3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... General Provisions § 14.3 Observers at tests and evaluations. Representatives of the applicant and...

  10. Post-occupancy evaluation and field studies of thermal comfort

    Energy Technology Data Exchange (ETDEWEB)

    Nicol, F.; Roaf, S.

    2005-08-01

    The similarities and differences are explored in both the aims and the methods between post-occupancy evaluations and field studies of thermal comfort in buildings. The interpretations of the field study results are explored, especially the ways the results differ from laboratory experiments. Particular attention is drawn to the dynamic nature of the interaction between buildings and their occupants. Answers to questions of the type used in post-occupancy evaluations are compared with results from field studies of thermal comfort, and the implications of these findings for the evaluation of buildings and the conduct of post-occupancy evaluation are explored. Field studies of thermal comfort have shown that the way in which occupants evaluate the indoor thermal environment is context-dependent and varies with time. In using occupants as part of the means of measuring buildings, post-occupancy evaluations should be understood as reflecting the changing nature of the relationship between people, the climate and buildings. Surveys are therefore measuring a moving target, and close comparison based on such surveys need to take this in to account. (author)

  11. Antioxidant effects of nerolidol in mice hippocampus after open field test.

    Science.gov (United States)

    Nogueira Neto, José Damasceno; de Almeida, Antonia Amanda Cardoso; da Silva Oliveira, Johanssy; Dos Santos, Pauline Sousa; de Sousa, Damião Pergentino; de Freitas, Rivelilson Mendes

    2013-09-01

    The aim of this study was to evaluate the neuroprotective effects of nerolidol in mice hippocampus against oxidative stress in neuronal cells compared to ascorbic acid (positive control) as well as evaluated the nerolidol sedative effects by open field test compared to diazepam (positive control). Thirty minutes prior to behavioral observation on open field test, mice were intraperitoneally treated with vehicle, nerolidol (25, 50 and 75 mg/kg), diazepam (1 mg/kg) or ascorbic acid (250 mg/kg). To clarify the action mechanism of of nerolidol on oxidative stress in animals subjected to the open field test, Western blot analysis of Mn-superoxide dismutase and catalase in mice hippocampus were performed. In nerolidol group, there was a significant decrease in lipid peroxidation and nitrite levels when compared to negative control (vehicle). However, a significant increase was observed in superoxide dismutase and catalase activities in this group when compared to the other groups. Vehicle, diazepam, ascorbic acid and nerolidol groups did not affected Mn-superoxide dismutase, catalase mRNA or protein levels. Our findings strongly support the hypothesis that oxidative stress occurs in hippocampus. Nerolidol showed sedative effects in animals subjected to the open field test. Oxidative process plays a crucial role on neuronal pathological consequence, and implies that antioxidant effects could be achieved using this sesquiterpene.

  12. First field test of FiDeL The magnetic field description for the LHC

    CERN Document Server

    Bottura, L; Catalan-Lasheras, N; Deniau, L; Di Castro, M; Fartoukh, S; Giovannozzi, M; Hagen, P; Koutchouk, Jean-Pierre; Lamont, M; Miles, J; Remondino, V; Sammut, N; Sanfilippo, S; Schmidt, F; Sernelius, D; Steinhagen, R; Strzelczyk, M; Tomás, R; Todesco, E; Venturini-Delsolaro, W; Walckiers, L; Wenninger, J; Wolf, R; Xydi, P

    2010-01-01

    The start-up of the LHC has provided the first field test for the concept, functionality and accuracy of FiDeL, the Field Description for the LHC. FiDeL provides a parametric model of the transfer function of the main field integrals generated by the series of magnets in the LHC powering circuits, comprising superconducting and normal-conducting main optical elements and high-order harmonic correctors. The same framework is used to predict harmonic errors of both static and dynamic nature, and forecast appropriate corrections. In this paper we make use of beam-based measurements taken on the first LHC beams to assess the first-shot accuracy in the prediction of the current setting for the main arc magnets.

  13. Field Testing of Compartmentalization Methods for Multifamily Construction

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States); Lstiburek, J. [Building Science Corporation, Westford, MA (United States)

    2015-03-01

    The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single-family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, driving the need for easier and more effective methods of compartmentalization in multifamily buildings. Builders and practitioners have found that fire-resistance rated wall assemblies are a major source of difficulty in air sealing/compartmentalization, particularly in townhouse construction. This problem is exacerbated when garages are “tucked in” to the units and living space is located over the garages. In this project, Building Science Corporation examined the taping of exterior sheathing details to improve air sealing results in townhouse and multifamily construction, when coupled with a better understanding of air leakage pathways. Current approaches are cumbersome, expensive, time consuming, and ineffective; these details were proposed as a more effective and efficient method. The effectiveness of these air sealing methods was tested with blower door testing, including “nulled” or “guarded” testing (adjacent units run at equal test pressure to null out inter-unit air leakage, or “pressure neutralization”). Pressure diagnostics were used to evaluate unit-to-unit connections and series leakage pathways (i.e., air leakage from exterior, into the fire-resistance rated wall assembly, and to the interior).

  14. Modular Integrated Monitoring System (MIMS) field test installations

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, R.L.; Waymire, D.R. [Sandia National Labs., Albuquerque, NM (United States); Fuess, D.A. [Lawrence Livermore National Lab., CA (United States)] [and others

    1995-07-01

    The MIMS program is funded by the Department of Energy under the Office of Nonproliferation and National Security. The program objective is to develop cost effective, modular, multi-sensor monitoring systems. Both in-plant and ground based sensors are envisioned. It is also desirable to develop sensors/systems that can be fielded/deployed in a rapid fashion. A MIMS architecture was selected to allow modular integration of sensors and systems and is based on LonWorks technology, commercially developed by Echelon Corporation. The first MIMS fieldable hardware was demonstrated at Lawrence Livermore National Laboratory. The field test, known within the DOE as the Item Tracking and Transparency (IT&I) demonstration, involved the collaboration and cooperation of five DOE laboratories (Sandia (SNL), Lawrence Livermore (LLNL), Pacific Northwest (PNL), Los Alamos (LANL), and Oak Ridge (ORNL)). The IT&T demonstration involved the monitoring of special nuclear material as it was transported around the facility utilizing sensors from the participating labs. The scenario was programmed to ignore normal activity in the facility until entry into the room where the material was stored. A second demonstration, which involved three separate scenarios, was conducted at Idaho National Engineering Laboratory (INEL). The participants included representatives from SNL, LLNL, PNL, and INEL. DOE has selected INEL as the long term testbed for MIMS developed sensors, systems, and scenarios. This paper will describe the installation, intended purpose, and results of the field demonstrations at LLNL and INEL under the MIMS program.

  15. 40 CFR 63.2354 - What performance tests, design evaluations, and performance evaluations must I conduct?

    Science.gov (United States)

    2010-07-01

    ... evaluations, and performance evaluations must I conduct? 63.2354 Section 63.2354 Protection of Environment... tests, design evaluations, and performance evaluations must I conduct? (a)(1) For each performance test... procedures specified in subpart SS of this part. (3) For each performance evaluation of a continuous...

  16. [Postcoital test evaluated in peritoneal fluid].

    Science.gov (United States)

    Radwan, J; Bielak, A; Niwald, W; Pawlicki, J; Banaszczyk, R; Makuła, D

    1995-04-01

    The role of the peritoneal fluid in the physiology of reproduction, as well as in the transportation and survival of gametes, is little recognized. Taking this into consideration, the authors have examined the occurrence of spermatozoa in the peritoneal fluid, collected from patients during diagnostic laparoscopies, following intrauterine insemination with husband's sperm, in, so-called, Templeton's Test. In the group of patients with cervical factor six (6) mobile spermatozoa (85%) were observed, in the group with male factor -- three (3) (42%) and in the group with idiopathic infertility -- 1 (25%). A high utility of this test has been indicated, especially in infertility caused by the male factor and in endometriosis.

  17. An Evaluation of Saxon's Algebra Test.

    Science.gov (United States)

    Johnson, Dale M.; Smith, Blaine

    1987-01-01

    John Saxon's incremental development model has been proclaimed as a superior teaching strategy for mathematics. This study evaluated the Saxon approach and textbook using 276 Algebra I students in experimental and control groups. The groups were compared in cognitive and affective areas. Results are presented. (Author/MT)

  18. An Evaluation of Saxon's Algebra Test.

    Science.gov (United States)

    Johnson, Dale M.; Smith, Blaine

    1987-01-01

    John Saxon's incremental development model has been proclaimed as a superior teaching strategy for mathematics. This study evaluated the Saxon approach and textbook using 276 Algebra I students in experimental and control groups. The groups were compared in cognitive and affective areas. Results are presented. (Author/MT)

  19. Field test of hydrogen in the natural gas grid

    Energy Technology Data Exchange (ETDEWEB)

    Iskov, H.

    2010-08-15

    In order to prepare for a future use of hydrogen as a fuel gas it became evident that very little information existed regarding the compatibility between long-term exposure and transportation of hydrogen in natural gas pipelines. A program was therefore set to study the transportation in a small-scale pilot grid at the research centre in Hoersholm, Denmark. The test program included steel pipes from the Danish gas transmission grid and polymer pipes from the Danish and Swedish gas distribution grid. The test of polymer pipes was devised so that samples of all test pipes were cut out of the grid each year and analysis performed on these pipe samples; in this way any form of influence on the integrity of the polyethylene pipe would be detected. The analytical program for polymer was devised in order to detect any influence on the additivation of the polyethylene as this has an influence on oxidative resistance, as well as checking already encountered possible degradation caused by extrusion of the material. Further tools as rheology and melt flow rate were used for detecting any structural changes on the material. On the mechanical property side the tensile strength and modulus were followed as well as the most important property for the pipe line, namely slow crack growth. The results of the polymer pipe tests show no degradations of any kind related to the continuous hydrogen exposure for more than 4 years. This is a strong indication of the compatibility to hydrogen of the tested polymer materials PE 80 and PE 100. The object of the steel pipe test was to see the effect on fatigue life of existing natural gas transmission lines with hydrogen replacing the natural gas. Full-scale dynamic tests were performed using randomly selected cut-out API 5L X70 pipe sections with a diameter of 20 inches and a wall thickness of 7 millimetres from the Danish natural gas transmission system. The pipe sections contained field girth weld made during the installation of the pipe

  20. Fischer-Tropsch Synthetic Fuel Evaluations HMMWV Test Track Evaluation

    Science.gov (United States)

    2009-09-01

    FBP Final boiling point FTM Federal Test Method FTP Federal Test Procedure g/kw-h Grams per kilowatt-hour g/mi Grams per...frequency reciprocating rig Hr Hour HMMWV High Mobility Medium Wheeled Vehicle IBP Initial boiling point Kg Kilo-gram L Liter Lbs...Standard deviation SwRI Southwest Research Institute TFLRF U.S. Army TARDEC Fuels and Lubricants Research Facility THC Total hydrocarbons

  1. Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Pilot-Scale Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Gary M. Blythe

    2006-03-01

    This Topical Report summarizes progress on Cooperative Agreement DE-FC26-04NT42309, ''Field Testing of a Wet FGD Additive.'' The objective of the project is to demonstrate the use of a flue gas desulfurization (FGD) additive, Degussa Corporation's TMT-15, to prevent the reemissions of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project intends to demonstrate that the additive can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine TMT salt that can be separated from the FGD liquor and bulk solid byproducts for separate disposal. The project will conduct pilot and full-scale tests of the TMT-15 additive in wet FGD absorbers. The tests are intended to determine required additive dosage requirements to prevent Hg{sup 0} reemissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Power River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, TXU Generation Company LP, Southern Company, and Degussa Corporation. TXU Generation has provided the Texas lignite/PRB co-fired test site for pilot FGD tests, Monticello Steam Electric Station Unit 3. Southern Company is providing the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, as well as the pilot and full-scale jet bubbling reactor (JBR) FGD systems to be tested. A third utility, to be named later, will provide the high-sulfur Eastern bituminous coal full-scale FGD test site. Degussa Corporation is providing the TMT-15 additive and technical support to the test program. The project is being conducted in six tasks. Of the six project tasks, Task 1 involves project planning and Task 6 involves management and reporting. The other four tasks involve field testing on FGD systems, either at pilot or full scale. The four tasks include: Task 2

  2. Test and Evaluation (T&E)

    Science.gov (United States)

    2013-03-04

    TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT Same as Report ( SAR ) 18. NUMBER OF PAGES 28 19a. NAME OF RESPONSIBLE PERSON a...412 TW Edwards AFB Bistatic Radar Cross-Section Benefield Anechoic Chamber test PI Tony Quach AFRL/RY TCTTA Ed Utt 96 TW Eglin AFB High Power

  3. Solar Technology Test, Evaluation, and Data Collection: Cooperative Research and Development Final Report, CRADA Number CRD-08-279

    Energy Technology Data Exchange (ETDEWEB)

    Albin, David S. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-03-08

    Under this Agreement, NREL will work with Abengoa Solar Inc. on the testing, evaluation, and collection of data related to Abengoa Solar Inc. solar technologies and systems. This work includes, but is not limited to, testing and evaluation of solar component and system technologies, data collection and monitoring, performance evaluation, reliability testing, thermal energy storage integration, solar resource measurement and forecasting, grid impact testing, and analysis. This work will be conducted at NREL, SolarTAC (Aurora), and other field test locations.

  4. 40 CFR 610.25 - Evaluation of test data.

    Science.gov (United States)

    2010-07-01

    ... effects on fuel economy, and on emissions, with statistical or other caveats as established by the data... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary...

  5. A field screening method using earthworms (Eisenia foetida andrei) to evaluate contaminated soils

    Energy Technology Data Exchange (ETDEWEB)

    Wilborn, D.C.; Bollman, M.A.; Gillett, C.S.; Ott, S.L.; Linder, G.L. [Takena Ecological Services, Inc., Corvallis, OR (United States)

    1997-09-01

    An on-site biological assessment for soil toxicity was performed using a lumbricid earthworm, Eisenia foetida andrei, at the Milltown Reservoir Superfund Site on the Clark Fork River near Missoula, MT. The assessment provided an opportunity to evaluate test containers and methodologies. Sixty-four field test stations, each consisting of three test containers of site soil, a control container of artificial soil, and a container to house soil moisture and temperature recording devices, were used. Laboratory tests were conducted on soil samples from selected field stations. The test containers were constructed from sections of polyvinyl chloride pipe and were found to be suitable in preventing escape of test organisms and damage by animals. The site soils had levels of arsenic, lead, cadmium, copper, and zinc higher than those in surrounding watersheds. Combined mortality for exposure to the site soil was similar in both the laboratory and field tests. Combined sublethal responses to the site soil were also similar in both laboratory and field tests. Artificial soil controls in both field and laboratory tests resulted in combined mortality rates of 1% or less. The methodologies employed proved successful in maintaining an adequate soil moisture level and allowed for measurement of soil temperature.

  6. 76 FR 3075 - Availability of an Environmental Assessment for Field Testing Feline Leukemia Vaccine, Live...

    Science.gov (United States)

    2011-01-19

    ... Feline Leukemia Vaccine, Live Canarypox Vector AGENCY: Animal and Plant Health Inspection Service, USDA... testing, and then to field test, an unlicensed Feline Leukemia Vaccine, Live Canarypox Vector. The.... Product: Feline Leukemia Vaccine, Live Canarypox Vector. Field Test Locations: Alabama,...

  7. 77 FR 22283 - Availability of an Environmental Assessment for Field Testing Feline Interleukin-2...

    Science.gov (United States)

    2012-04-13

    ... Feline Interleukin-2 Immunomodulator, Live Canarypox Vector AGENCY: Animal and Plant Health Inspection... of field testing, and then to field test, an unlicensed Feline Interleukin-2 ] Immunomodulator, Live... testing of the following unlicensed veterinary biological product: Requester: Merial, Inc. Product:...

  8. The Evaluation of Noise Spectroscopy Tests

    Directory of Open Access Journals (Sweden)

    Pavel Fiala

    2016-12-01

    Full Text Available The paper discusses mathematical tools to evaluate novel noise spectroscopy based analysis and describes, via physical similarity, the mathematical models expressing the quantitative character of the modeled task. Using the Stefan–Boltzmann law, the authors indicate finding the spectral density of the radiated power of a hemisphere, and, for the selected frequency interval and temperature, they compare the simplified models with the expression of noise spectral density according to the Johnson–Nyquist formula or Nyquist’s expression of the function of spectral density based on a derivation of Planck’s law. The related measurements and evaluations, together with analyses of the noise spectroscopy of periodic resonant structures, are also outlined in the given context.

  9. ASTM test methods for composite characterization and evaluation

    Science.gov (United States)

    Masters, John E.

    1994-01-01

    A discussion of the American Society for Testing and Materials is given. Under the topic of composite materials characterization and evaluation, general industry practice and test methods for textile composites are presented.

  10. The Evaluation of Noise Spectroscopy Tests

    OpenAIRE

    Pavel Fiala; Petr Drexler; Dusan Nespor; Zoltan Szabo; Jan Mikulka; Jiri Polivka

    2016-01-01

    The paper discusses mathematical tools to evaluate novel noise spectroscopy based analysis and describes, via physical similarity, the mathematical models expressing the quantitative character of the modeled task. Using the Stefan–Boltzmann law, the authors indicate finding the spectral density of the radiated power of a hemisphere, and, for the selected frequency interval and temperature, they compare the simplified models with the expression of noise spectral density according to the Johnso...

  11. Tests for evaluating the physiological quality of pitaya seeds

    National Research Council Canada - National Science Library

    Thiago Alberto Ortiz; Aline Moritz; Lúcia Sadayo Assari Takahashi; Mariana Ragassi Urbano

    2015-01-01

    .... Thus, this study aimed to develop methodologies for conducting tests of germination, accelerated aging, and electrical conductivity for the evaluation of the physiological quality of pitaya seeds...

  12. Field evaluation of hazardous waste site bioassessment protocols

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, J.M.; Cline, J.F.; Cushing, C.E.; McShane, M.C.; Rogers, J.E.; Rogers, L.E.; Simpson, J.C.; Skalski, J.R.

    1983-04-01

    The goals were: (1) determine the variability (both within and between laboratories) for the various bioassay procedures using contaminated soil samples from the Rocky Mountain Arsenal (RMA); (2) assess variability within and between plots for several assessment techniques (for sampling small mammals, plants, insects including honeybees and microarthropods) so that field studies could be designed to detect a defined biotic change; (3) establish three field plant transects which are apparently (a) contaminated, (b) appear contaminated and (c) could serve as a control; (4) assess the feasibility (in the laboratory) of using Basin F water to contaminate RMA soil artificially, and to supply information for the design of a field plot study in 1983; (5) attempt to obtain preliminary data on any promising field or laboratory bioassessment techniques not currently mentioned in the statement of work; and (6) obtain field data to assess the ecological status of RMA lakes and compare these observations to results from bioassessment testing.

  13. The Operational Testing Effectiveness Evaluation Method

    Science.gov (United States)

    1988-04-01

    compared, testing methods improved, and critics silenced . Given that checking IOT&E assessments against operational data seemed to be common sense, was...history of OT&E, discussing the poasibility that the record of frequent convulsive organizational change is related to the lack of adequate feedback on... silence the critics, and ultimately ensure that the weapons reaching the ramp really are effective and suitable. 30 ~• x , .-.-. I- BIBLIOGRAPH d Books

  14. Evaluation of the finger wrinkling test : a pilot study

    NARCIS (Netherlands)

    van Barneveld, S.; van der Palen, J.; van Putten, M. J. A. M.

    2010-01-01

    Tilt table testing mainly evaluates the systemic cardiovascular part of the autonomic nervous system, while it is assumed that the finger wrinkling test assesses the peripheral part of the autonomic nervous system. In this study we explored whether the finger wrinkling test could be a useful test fo

  15. Cooperative field test program for wind systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bollmeier, W.S. II; Dodge, D.M.

    1992-03-01

    The objectives of the Federal Wind Energy Program, managed by the US Department of Energy (DOE), are (1) to assist industry and utilities in achieving a multi-regional US market penetration of wind systems, and (2) to establish the United States as the world leader in the development of advanced wind turbine technology. In 1984, the program conducted a series of planning workshops with representatives from the wind energy industry to obtain input on the Five-Year Research Plan then being prepared by DOE. One specific suggestion that came out of these meetings was that the federal program should conduct cooperative research tests with industry to enhance the technology transfer process. It was also felt that the active involvement of industry in DOE-funded research would improve the state of the art of wind turbine technology. DOE established the Cooperative Field Test Program (CFTP) in response to that suggestion. This program was one of the first in DOE to feature joint industry-government research test teams working toward common objectives.

  16. Design and Field Test of a Galvanometer Deflected Streak Camera

    Energy Technology Data Exchange (ETDEWEB)

    Lai, C C; Goosman, D R; Wade, J T; Avara, R

    2002-11-08

    We have developed a compact fieldable optically-deflected streak camera first reported in the 20th HSPP Congress. Using a triggerable galvanometer that scans the optical signal, the imaging and streaking function is an all-optical process without incurring any photon-electron-photon conversion or photoelectronic deflection. As such, the achievable imaging quality is limited mainly only by optical design, rather than by multiple conversions of signal carrier and high voltage electron-optics effect. All core elements of the camera are packaged into a 12 inch x 24 inch footprint box, a size similar to that of a conventional electronic streak camera. At LLNL's Site-300 Test Site, we have conducted a Fabry-Perot interferometer measurement of fast object velocity using this all-optical camera side-by-side with an intensified electronic streak camera. These two cameras are configured as two independent instruments for recording synchronously each branch of the 50/50 splits from one incoming signal. Given the same signal characteristics, the test result has undisputedly demonstrated superior imaging performance for the all-optical streak camera. It produces higher signal sensitivity, wider linear dynamic range, better spatial contrast, finer temporal resolution, and larger data capacity as compared with that of the electronic counterpart. The camera had also demonstrated its structural robustness and functional consistence to be well compatible with field environment. This paper presents the camera design and the test results in both pictorial records and post-process graphic summaries.

  17. Field accuracy of fourth-generation rapid diagnostic tests for acute HIV-1: a systematic review

    OpenAIRE

    2015-01-01

    Introduction: Fourth-generation HIV-1 rapid diagnostic tests (RDTs) detect HIV-1 p24 antigen to screen for acute HIV-1. However, diagnostic accuracy during clinical use may be suboptimal. Methods: Clinical sensitivity and specificity of fourth-generation RDTs for acute HIV-1 were collated from field evaluation studies in adults identified by a systematic literature search. Results: Four studies with 17 381 participants from Australia, Swaziland, the United Kingdom and Malawi were identified. ...

  18. [Progress of the micronucleus test in the field of molecular cancer epidemiology].

    Science.gov (United States)

    Xu, Huadong; Jia, Guang

    2015-01-01

    The micronucleus test (MNT) can be used to detect multiple genetic end points simultaneously, including chromosome aberration, mis-repaired DNA damage, apoptosis, parts of mutation and so on, which MNT has been an important part of the study of cancer epidemiology.Here, we reviewed the progress of MNT in the field of molecular cancer epidemiology in recent years, including early detection and diagnosis of cancer, evaluation of carcinogenic substances, genetic susceptibility biomarkers, micronutrient and cohort studies.

  19. Smart Parking Linked to Transit: Lessons Learned from the San Francisco Bay Area Field Test

    OpenAIRE

    Shaheen, Susan; Kemmerer, Charlene

    2007-01-01

    Rising demand for parking at suburban transit stations, such as the Bay Area Rapid Transit (BART) District in California, necessitates strategies to manage traveler demand. To better manage parking supply, researchers implemented a smart parking field test at the Rockridge BART station from 2004 to 2006 to evaluate the effects of smart parking technologies (changeable message signs (CMSs), Internet reservations and billing, mobile phone and personal digital assistant communications, and a wir...

  20. Testability integrated evaluation method based on testability virtual test data

    Institute of Scientific and Technical Information of China (English)

    Liu Guanjun; Zhao Chenxu; Qiu Jing; Zhang Yong

    2014-01-01

    Testability virtual test is a new test method for testability verification, which has the advantages such as low cost, few restrictions and large sample of test data. It can be used to make up the deficiency of testability physical test. In order to take the advantage of testability virtual test data effectively and to improve the accuracy of testability evaluation, a testability integrated eval-uation method is proposed in this paper based on testability virtual test data. Considering the char-acteristic of testability virtual test data, the credibility analysis method for testability virtual test data is studied firstly. Then the integrated calculation method is proposed fusing the testability vir-tual and physical test data. Finally, certain helicopter heading and attitude system is presented to demonstrate the proposed method. The results show that the testability integrated evaluation method is feasible and effective.

  1. Patch Testing In Soldiers : An Evaluation

    Directory of Open Access Journals (Sweden)

    Walia N. S

    2004-01-01

    Full Text Available Our study concerns contact sensitization in soldiers, the frequency of which is poorly documented. During a six-year period, 128 patients of age range 17-50 years were patch tested with the Indian standard battery of 30 allergens. We obtained a reaction in 23 (18% of our patients. Nickel sulfate, fragrance mix, wool alcohol and parthenium induced most of the positive responses. In addition, an irritant reaction was seen in 16 (12.5% of our patients. Patients of atopic dermatitis and hand/foot dermatoses evoked a high sensitivity response. Adverse effects were seen in 15 patients.

  2. Test particle transport in perturbed magnetic fields in tokamaks

    NARCIS (Netherlands)

    de Rover, M.; Schilham, A.M.R.; Montvai, A.; Cardozo, N. J. L.

    1999-01-01

    Numerical calculations of magnetic field line trajectories in a tokamak are used to investigate the common hypotheses that (i) field lines in a chaotic field make a Gaussian random walk and (ii) that the poloidal component of the magnetic field is uniform in regions with a chaotic magnetic field. Bo

  3. EVA Metro Sedan electric-propulsion system: test and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Reimers, E.

    1979-09-01

    The procedure and results of the performance evaluation of the EVA Metro Sedan (car No. 1) variable speed dc chopper motor drive and its three speed automatic transmission are presented. The propulsion system for a battery powered vehicle manufactured by Electric Vehicle Associates, Valley View, Ohio, was removed from the vehicle, mounted on the programmable electric dynamometer test facility and evaluated with the aid of a hp 3052A Data Acquisition System. Performance data for the automatic transmission, the solid state dc motor speed controller, and the dc motor in the continuous and pulsating dc power mode, as derived on the dynamometer test facility, as well as the entire propulsion system are given. This concept and the system's components were evaluated in terms of commercial applicability, maintainability, and energy utility to establish a design base for the further development of this system or similar propulsion drives. The propulsion system of the EVA Metro Sedan is powered by sixteen 6-volt traction batteries, Type EV 106 (Exide Battery Mfg. Co.). A thyristor controlled cable form Pulsomatic Mark 10 controller, actuated by a foot throttle, controls the voltage applied to a dc series field motor, rated at 10 hp at 3800 rpm (Baldor Electric Co.). Gear speed reduction to the wheel is accomplished by the original equipment three speed automatic transmission with torque converter (Renault 12 Sedan). The brake consists of a power-assisted, hydraulic braking system with front wheel disk and rear drum. An ability to recuperate electric energy with subsequent storage in the battery power supply is not provided.

  4. Laboratory and field evaluation of hot mix asphalt with high contents of reclaimed asphalt pavement

    Science.gov (United States)

    Van Winkle, Clinton Isaac

    Currently in Iowa, the amount of RAP materials allowed for the surface layer is limited to 15% by weight. The objective of this project was to develop quality standards for inclusion of RAP content higher than 15% in asphalt mixtures. To meet Superpave mix design requirements, it was necessary to fractionate the RAP materials. Based on the extensive sieve-by-sieve analysis of RAP materials, the optimum sieve size to fractionate RAP materials was identified. To determine if the higher percentage of RAP materials than 15% can be used in Iowa's state highway, three test sections with 30.0%, 35.5% and 39.2% of RAP materials were constructed on Highway 6 in Iowa City. The construction of the field test sections was monitored and the cores were obtained to measure field densities of test sections. Field mixtures collected from test sections were compacted in the laboratory in order to test the moisture sensitivity using a Hamburg Wheel Tracking Device. The binder was extracted from the field mixtures with varying amounts of RAP materials and tested to determine the effects of RAP materials on the PG grade of a virgin binder. Field cores were taken from the various mix designs to determine the percent density of each test section. A condition survey of the test sections was then performed to evaluate the short-term performance.

  5. Testing Einstein's Equivalence Principle with supercluster Laniakea's gravitational field

    Science.gov (United States)

    Luo, Zhi-Xing; Zhang, Bo; Wei, Jun-Jie; Wu, Xue-Feng

    2016-03-01

    Comparing the parameterized post-Newtonian parameter γ values for different types of particles, or the same type of particles with different energies is an important method to test the Einstein Equivalence Principle (EEP). Assuming that the observed time delays are dominated by the gravitational potential of the Laniakea supercluster of galaxies, better results of EEP constraints can be obtained. In this paper, we apply photons from three kinds of cosmic transients, including TeV blazars, gamma-ray bursts as well as fast radio bursts to constrain EEP. With a gravitational field far more stronger than a single galaxy, we obtain 4-5 orders of magnitude more stringent than the previous results.

  6. Testing Einstein's Equivalence Principle with Supercluster Laniakea's Gravitational Field

    CERN Document Server

    Luo, Zhi-Xing; Wei, Jun-Jie; Wu, Xue-Feng

    2016-01-01

    Comparing the parameterized post-Newtonian parameter $\\gamma$ values for different types of particles, or the same type of particles with different energies is an important method to test the Einstein Equivalence Principle (EEP). Assuming that the observed time delays are dominated by the gravitational potential of the Laniakea supercluster of galaxies, better results of EEP constraints can be obtained. In this paper, we apply photons from three kinds of cosmic transients, including TeV blazars, gamma-ray bursts as well as fast radio bursts to constrain EEP. With a gravitational field far more stronger than a single galaxy, we obtain 4--5 orders of magnitude more stringent than the pervious results.

  7. Numerical Tests of Fast Reconnection in Weakly Stochastic Magnetic Fields

    CERN Document Server

    Kowal, G; Vishniac, E T; Otmianowska-Mazur, K

    2009-01-01

    We study the effects of turbulence on magnetic reconnection using 3D numerical simulations. This is the first attempt to test a model of fast magnetic reconnection in the presence of weak turbulence proposed by Lazarian & Vishniac (1999). This model predicts that weak turbulence, generically present in most of astrophysical systems, enhances the rate of reconnection by reducing the transverse scale for reconnection events and by allowing many independent flux reconnection events to occur simultaneously. As a result the reconnection speed becomes independent of Ohmic resistivity and is determined by the magnetic field wandering induced by turbulence. To quantify the reconnection speed we use both an intuitive definition, i.e. the speed of the reconnected flux inflow, as well as a more sophisticated definition based on a formally derived analytical expression. Our results confirm the predictions of the Lazarian & Vishniac model. In particular, we find that Vrec Pinj^(1/2), as predicted by the model. The...

  8. A field test of a simple stochastic radiative transfer model

    Energy Technology Data Exchange (ETDEWEB)

    Byrne, N. [Science Applications International Corp., San Diego, CA (United States)

    1995-09-01

    The problem of determining the effect of clouds on the radiative energy balance of the globe is of well-recognized importance. One can in principle solve the problem for any given configuration of clouds using numerical techniques. This knowledge is not useful however, because of the amount of input data and computer resources required. Besides, we need only the average of the resulting solution over the grid scale of a general circulation model (GCM). Therefore, we are interested in estimating the average of the solutions of such fine-grained problems using only coarse grained data, a science or art called stochastic radiation transfer. Results of the described field test indicate that the stochastic description is a somewhat better fit to the data than is a fractional cloud cover model, but more data are needed. 1 ref., 3 figs.

  9. Field test on temperature field and thermal stress for prestressed concrete box-girder bridge

    Institute of Scientific and Technical Information of China (English)

    Baoguo CHEN; Rui DING; Junjie ZHENG; Shibiao ZHANG

    2009-01-01

    A field test was conducted to investigate the distribution of temperature field and the variation of thermal stress for a prestressed concrete (PC) box-girder bridge. The change of hydration heat temperature consists of four periods: temperature rising period, constant temperature period, rapid temperature fall period and stow temperature fall period. The peak value of hydration heat temperature increases with the increasing casting temperature of concrete; the relation between them is approximately linear. According to field tests, the thermal stress incurred by hydration heat may induce temperature cracks on the PC box-girder. Furthermore, the nonlinear distribution of temperature gradient and the fluctuation of thermal stress induced by exposure to sunlight were also obtained based on continuous in-situ monitoring. Such results show that the prevailing Chinese Code (2004) is insufficient since it does not take into account the temperature gradient of the bottom slab. Finally, some preventive measures against temperature cracks were proposed based on related studies. The conclusions can provide valuable reference for the design and construction of PC box-girder bridges.

  10. Evaluation in the Field: The Need for Site Visit Standards

    Science.gov (United States)

    Patton, Michael Quinn

    2015-01-01

    Our understanding of programs is enhanced when trained, skilled, and observant evaluators go "into the field"--the real world where programs are conducted--paying attention to what's going on, systematically documenting what they see, and reporting what they learn. The article opens by presenting and illustrating twelve reasons for…

  11. FIELD EVALUATION OF A HIGH-VOLUME DICHOTOMOUS SAMPLER

    Science.gov (United States)

    This study presents the field evaluation of a high-volume dichotomous sampler that collects coarse (PM10-2.5) and fine (PM2.5) particulate matter. The key feature of this device is the utilization of a round-nozzle virtual impactor with a 50% cutpoint at 2.5 5m to split PM10 into...

  12. Testing neoclassical competitive market theory in the field.

    Science.gov (United States)

    List, John A

    2002-11-26

    This study presents results from a pilot field experiment that tests predictions of competitive market theory. A major advantage of this particular field experimental design is that my laboratory is the marketplace: subjects are engaged in buying, selling, and trading activities whether I run an exchange experiment or am a passive observer. In this sense, I am gathering data in a natural environment while still maintaining the necessary control to execute a clean comparison between treatments. The main results of the study fall into two categories. First, the competitive model predicts reasonably well in some market treatments: the expected price and quantity levels are approximated in many market rounds. Second, the data suggest that market composition is important: buyer and seller experience levels impact not only the distribution of rents but also the overall level of rents captured. An unexpected result in this regard is that average market efficiency is lowest in markets that match experienced buyers and experienced sellers and highest when experienced buyers engage in bargaining with inexperienced sellers. Together, these results suggest that both market experience and market composition play an important role in the equilibrium discovery process.

  13. Advanced Utility Mercury-Sorbent Field-Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Ronald Landreth

    2007-12-31

    This report summarizes the work conducted from September 1, 2003 through December 31, 2007 on the project entitled Advanced Utility Mercury-Sorbent Field-Testing Program. The project covers the testing at the Detroit Edison St. Clair Plant and the Duke Power Cliffside and Buck Stations. The St. Clair Plant used a blend of subbituminous and bituminous coal and controlled the particulate emissions by means of a cold-side ESP. The Duke Power Stations used bituminous coals and controlled their particulate emissions by means of hot-side ESPs. The testing at the Detroit Edison St. Clair Plant demonstrated that mercury sorbents could be used to achieve high mercury removal rates with low injection rates at facilities that burn subbituminous coal. A mercury removal rate of 94% was achieved at an injection rate of 3 lb/MMacf over the thirty day long-term test. Prior to this test, it was believed that the mercury in flue gas of this type would be the most difficult to capture. This is not the case. The testing at the two Duke Power Stations proved that carbon- based mercury sorbents can be used to control the mercury emissions from boilers with hot-side ESPs. It was known that plain PACs did not have any mercury capacity at elevated temperatures but that brominated B-PAC did. The mercury removal rate varies with the operation but it appears that mercury removal rates equal to or greater than 50% are achievable in facilities equipped with hot-side ESPs. As part of the program, both sorbent injection equipment and sorbent production equipment was acquired and operated. This equipment performed very well during this program. In addition, mercury instruments were acquired for this program. These instruments worked well in the flue gas at the St. Clair Plant but not as well in the flue gas at the Duke Power Stations. It is believed that the difference in the amount of oxidized mercury, more at Duke Power, was the difference in instrument performance. Much of the equipment was

  14. Field and storage testing Bt potatoes for resistance to potato tuberworm (Lepidoptera: Gelichiidae).

    Science.gov (United States)

    Douches, D S; Pett, W; Santos, F; Coombs, J; Grafius, E; Li, W; Metry, E A; el-Din, T Nasr; Madkour, M

    2004-08-01

    Potato tuberworm, Phthorimaea operculella (Zeller), is the most serious insect pest of potatoes worldwide. The introduction of the Bacillus thuringiensis (Bt) toxin gene through genetic engineering offers host plant resistance for the management of potato tuberworm. We report on the field and storage studies to evaluate Bt-cry5 potato lines for resistance to potato tuberworm in Egypt under natural infestations and their agronomic performance in both Egypt and Michigan. From 1997 to 2001, field experiments were conducted at the International Potato Center (CIP) Research Station, Kafr El-Zyat, Egypt, and/or Agricultural Genetic Engineering Institute (AGERI), Giza, Egypt, to evaluate resistance to tuberworm. A total of 27 Bt-transgenic potato lines from six different Bt constructs were evaluated over a 5-yr period. After harvest and evaluation of the agronomic trials, storage evaluation of potato tuberworm damage was done at the CIP Research Station. The 1997 field trial was the first field test of genetically engineered crops in Egypt. Field tests to assess potato tuberworm resistance in Egypt were able to differentiate between the Bt-transgenic lines and the nontransgenic lines/cultivars in 1999, 2000, and 2001. The Bt-cry5-Spunta lines (Spunta-G2, Spunta-G3, and Spunta-6a3) were the most resistant lines in field with 99-100% of tubers free of damage. In the 2001 storage study, these lines were also over 90% free of tuberworm damage after 3 mo. NYL235-4.13, which combines glandular trichomes with the Bt-cry5/gus fusion construct, also had a high percentage of clean tubers in the field studies. In agronomic field trials in Michigan from 1997 to 2001, the Bt-transgenic lines in most instances performed similar to the nontransgenic line in the agronomic trials; however, in Egypt (1998-1999), the yields were less than one-half of those in Michigan. Expression of the Bt-cry5 gene in the potato tuber and foliage will provide the seed producer and grower a tool in which to

  15. Nondestructive Evaluation of Railway Bridge by System Identification Using Field Vibration Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Duc Duy; Hong, Dong Soo; Kim, Jeong Tae [Pukyong National University, Busan (Korea, Republic of)

    2010-12-15

    This paper presents a nondestructive evaluation approach for system identification (SID) of real railway bridges using field vibration test results. First, a multi-phase SID scheme designed on the basis of eigenvalue sensitivity concept is presented. Next, the proposed multi-phase approach is evaluated from field vibration tests on a real railway bridge (Wondongcheon bridge) located in Yangsan, Korea. On the steel girder bridge, a few natural frequencies and mode shapes are experimentally measured under the ambient vibration condition. The corresponding modal parameters are numerically calculated from a three-dimensional finite element (FE) model established for the target bridge. Eigenvalue sensitivities are analyzed for potential model-updating parameters of the FE model. Then, structural subsystems are identified phase-by-phase using the proposed model-updating procedure. Based on model-updating results, a baseline model and a nondestructive evaluation of test bridge are identified

  16. Economic evaluations and diagnostic testing: an illustrative case study approach.

    Science.gov (United States)

    Sanghera, Sabina; Orlando, Rosanna; Roberts, Tracy

    2013-01-01

    The aim of this study was to present a clear process of synthesizing test accuracy data when conducting economic evaluations of diagnostic tests for health technology assessment (HTA) assessors and health economists. We appraised the methods advocated for using diagnostic test accuracy data in economic evaluations. We used a case study of fetal anemia in which data from a screening test are used in combination with a confirmatory test. We developed a step-by-step guide and consider two scenarios: when data on test accuracy from several studies are based on (i) the same test threshold for positivity and (ii) different test thresholds. We conclude that each approach has its strengths and limitations. We show that the optimal operating point of the test should be identified to determine the true cost-effectiveness of the test. We advocate that these issues require a multidisciplinary team of health economists, decision modelers and statisticians.

  17. Software Test And Evaluation Center Of CASC Established

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    @@ The software Test and Evaluation Center of CASC(CASC-STEC) was established recently.The establishment of the CASC-STEC is an important measure to strengthen the capability of software test and evaluation,to ensure the quality of software products and improve the level of software engineering.

  18. Integration and Evaluation of Nanophotonic Devices Using Optical Near Field

    Science.gov (United States)

    Yatsui, Takashi; Nomura, Wataru; Yi, Gyu-Chul; Ohtsu, Motoichi

    In this chapter, we review the optical near-field phenomena and their applications to realize the nanophotonic device. To realize the nanometer-scale controllability in size and position, we demonstrate the feasibility of nanometer-scale chemical vapor deposition using optical near-field techniques (see Sect. 15.2). In which, the probe-less fabrication method for mass production is also demonstrated. To confirm the promising optical properties of individual ZnO for realizing nanophotonic devices, we performed the near-field evaluation of the ZnO quantum structure (see Sect. 15.3). To drive the nanophotonic device with external conventional diffraction-limited photonic device, the far-/near-field conversion device is required. Section 15.4 reviews nanometer-scale waveguide to be used as such a conversion device of the nanophotonic ICs.

  19. Test facilities for evaluating nuclear thermal propulsion systems

    Science.gov (United States)

    Beck, David F.; Allen, George C.; Shipers, Larry R.; Dobranich, Dean; Ottinger, Cathy A.; Harmon, Charles D.; Fan, Wesley C.; Todosow, Michael

    1993-01-01

    Interagency panels evaluating nuclear thermal propulsion (NTP) development options have consistently recognized the need for constructing a major new ground test facility to support fuel element and engine testing. This paper summarizes the requirements, configuration, and baseline performance of some of the major subsystems designed to support a proposed ground test complex for evaluating nuclear thermal propulsion fuel elements and engines being developed for the Space Nuclear Thermal Propulsion (SNTP) program. Some preliminary results of evaluating this facility for use in testing other NTP concepts are also summarized.

  20. Evaluating Computer-Based Test Accommodations for English Learners

    Science.gov (United States)

    Roohr, Katrina Crotts; Sireci, Stephen G.

    2017-01-01

    Test accommodations for English learners (ELs) are intended to reduce the language barrier and level the playing field, allowing ELs to better demonstrate their true proficiencies. Computer-based accommodations for ELs show promising results for leveling that field while also providing us with additional data to more closely investigate the…

  1. Integral test on activation cross section of tag gas nuclides using fast neutron spectrum fields

    Energy Technology Data Exchange (ETDEWEB)

    Aoyama, Takafumi; Suzuki, Soju [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1997-03-01

    Activation cross sections of tag gas nuclides, which will be used for the failed fuel detection and location in FBR plants, were evaluated by the irradiation tests in the fast neutron spectrum fields in JOYO and YAYOI. The comparison of their measured radioactivities and the calculated values using the JENDL-3.2 cross section set showed that the C/E values ranged from 0.8 to 2.8 for the calibration tests in YAYOI and that the present accuracies of these cross sections were confirmed. (author)

  2. Development of nondestructive testing/evaluation methodology for MEMS

    Science.gov (United States)

    Zunino, James L., III; Skelton, Donald R.; Marinis, Ryan T.; Klempner, Adam R.; Hefti, Peter; Pryputniewicz, Ryszard J.

    2008-02-01

    Development of MEMS constitutes one of the most challenging tasks in today's micromechanics. In addition to design, analysis, and fabrication capabilities, this task also requires advanced test methodologies for determination of functional characteristics of MEMS to enable refinement and optimization of their designs as well as for demonstration of their reliability. Until recently, this characterization was hindered by lack of a readily available methodology. However, using recent advances in photonics, electronics, and computer technology, it was possible to develop a NonDestructive Testing (NDT) methodology suitable for evaluation of MEMS. In this paper, an optoelectronic methodology for NDT of MEMS is described and its application is illustrated with representative examples; this description represents work in progress and the results are preliminary. This methodology provides quantitative full-field-of-view measurements in near real-time with high spatial resolution and nanometer accuracy. By quantitatively characterizing performance of MEMS, under different vibration, thermal, and other operating conditions, specific suggestions for their improvements can be made. Then, using the methodology, we can verify the effects of these improvements. In this way, we can develop better understanding of functional characteristics of MEMS, which will ensure that they are operated at optimum performance, are durable, and are reliable.

  3. Test definitions for the evaluation of digital waveform recorders.

    Energy Technology Data Exchange (ETDEWEB)

    Kromer, Richard Paul (R.P. Kromer Consulting, Albuquerque, NM); Hart, Darren M.; Harris, James Mark

    2007-07-01

    This Test Definition for the Evaluation of Digitizing Waveform Recorders (DWR) defines the process that can be performed as part of the evaluation and testing of geophysical sensors, digitizers, sensor subsystems and geophysical station/array systems. The objectives are to (1) evaluate the overall technical performance of the DWR, measure the distortions introduced by the high resolution digitizers and provide a performance check of the internal calibrator if provided and (2) evaluate the technical performance of the DWR for a specific sensor application. The results of these evaluations can be compared to the manufacturer's specifications and any relevant application requirements or specifications.

  4. Fenestration System Performance Research, Testing, and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jim Benney

    2009-11-30

    The US DOE was and is instrumental to NFRC's beginning and its continued success. The 2005 to 2009 funding enables NFRC to continue expanding and create new, improved ratings procedures. Research funded by the US DOE enables increased fenestration energy rating accuracy. International harmonization efforts supported by the US DOE allow the US to be the global leader in fenestration energy ratings. Many other governments are working with the NFRC to share its experience and knowledge toward development of their own national fenestration rating process similar to the NFRC's. The broad and diverse membership composition of NFRC allows anyone with a fenestration interest to come forward with an idea or improvement to the entire fenestration community for consideration. The NFRC looks forward to the next several years of growth while remaining the nation's resource for fair, accurate, and credible fenestration product energy ratings. NFRC continues to improve its rating system by considering new research, methodologies, and expanding to include new fenestration products. Currently, NFRC is working towards attachment energy ratings. Attachments are blinds, shades, awnings, and overhangs. Attachments may enable a building to achieve significant energy savings. An NFRC rating will enable fair competition, a basis for code references, and a new ENERGY STAR product category. NFRC also is developing rating methods to consider non specular glazing such as fritted glass. Commercial applications frequently use fritted glazing, but no rating method exists. NFRC is testing new software that may enable this new rating and contribute further to energy conservation. Around the world, many nations are seeking new energy conservation methods and NFRC is poised to harmonize its rating system assisting these nations to better manage and conserve energy in buildings by using NFRC rated and labeled fenestration products. As this report has shown, much more work needs to be

  5. The Evaluation of Diagnostic Tests for Sexually Transmitted Infections

    Directory of Open Access Journals (Sweden)

    Max A Chernesky

    2005-01-01

    Full Text Available Diagnostic tests should receive method- and use-effectiveness evaluations. Method-effectiveness evaluations determine sensitivity, specificity and predictive values for new tests. Use-effectiveness evaluations determine how practical or convenient a new test will be in a specific setting and may not be performed in a formal way in North American laboratories. To perform a clinical method evaluation of diagnostic tests, a good relationship between laboratory and clinical personnel is essential. Studies are usually conducted separately on populations of men and women, and should include sampling from different prevalence groups. Test performance comparisons may be made on a single specimen type or on more than one specimen from the same patient, which allows for the expansion of a reference standard and includes the ability of a particular assay, performed on a specimen type to diagnose an infected individual. The following components of the evaluation should be standardized and carefully followed: specimen identification; collection; transportation; processing; quality control; reading; proficiency testing; confirmatory testing; discordant analysis -- sensitivity, specificity and predictive value calculations; and record keeping. Methods are available to determine whether sample results are true or false positives or negatives. Use-effectiveness evaluations might determine the stability or durability of supplies and equipment; the logistics of shipping, receiving and storing supplies; the clarity and completeness of test instructions; the time and effort required to process and read results; the subjectivity factors in interpretation and reporting; and the costs. These determinations are usually more apparent for commercial assays than for homemade tests.

  6. The evaluation of diagnostic tests for sexually transmitted infections.

    Science.gov (United States)

    Chernesky, Max A

    2005-03-01

    Diagnostic tests should receive method- and use-effectiveness evaluations. Method-effectiveness evaluations determine sensitivity, specificity and predictive values for new tests. Use-effectiveness evaluations determine how practical or convenient a new test will be in a specific setting and may not be performed in a formal way in North American laboratories. To perform a clinical method evaluation of diagnostic tests, a good relationship between laboratory and clinical personnel is essential. Studies are usually conducted separately on populations of men and women, and should include sampling from different prevalence groups. Test performance comparisons may be made on a single specimen type or on more than one specimen from the same patient, which allows for the expansion of a reference standard and includes the ability of a particular assay, performed on a specimen type to diagnose an infected individual. The following components of the evaluation should be standardized and carefully followed: specimen identification; collection; transportation; processing; quality control; reading; proficiency testing; confirmatory testing; discordant analysis - sensitivity, specificity and predictive value calculations; and record keeping. Methods are available to determine whether sample results are true or false positives or negatives. Use-effectiveness evaluations might determine the stability or durability of supplies and equipment; the logistics of shipping, receiving and storing supplies; the clarity and completeness of test instructions; the time and effort required to process and read results; the subjectivity factors in interpretation and reporting; and the costs. These determinations are usually more apparent for commercial assays than for homemade tests.

  7. Colorimetric evaluation of iPhone apps for colour vision tests based on the Ishihara test

    National Research Council Canada - National Science Library

    Dain, Stephen J; AlMerdef, Ali

    2016-01-01

    ...) providing colour vision testing would appear as an option. In this study, the colorimetric characteristics of five available iPhone apps for colour vision testing are assessed as a prequel to possible clinical evaluation...

  8. Test and evaluation of a solar-heating system

    Science.gov (United States)

    1980-01-01

    Report documents results of evaluation tests performed on components of commerical solar heating and hot water system. Subsystems tested include flat plate solar collector, energy transport module, and control panel. Tests conducted include snow and wind loads, flame spread, and smoke classification as well as solar heating operation.

  9. Evaluation of the finger wrinkling test: a pilot study

    NARCIS (Netherlands)

    Barneveld, van S.; Palen, van der J.; Putten, van M.J.A.M

    2010-01-01

    Purpose: Tilt table testing mainly evaluates the systemic cardiovascular part of the autonomic nervous system, while it is assumed that the finger wrinkling test assesses the peripheral part of the autonomic nervous system. In this study we explored whether the finger wrinkling test could be a usefu

  10. Marking Strategies in Metacognition-Evaluated Computer-Based Testing

    Science.gov (United States)

    Chen, Li-Ju; Ho, Rong-Guey; Yen, Yung-Chin

    2010-01-01

    This study aimed to explore the effects of marking and metacognition-evaluated feedback (MEF) in computer-based testing (CBT) on student performance and review behavior. Marking is a strategy, in which students place a question mark next to a test item to indicate an uncertain answer. The MEF provided students with feedback on test results…

  11. A Communicative Approach to Second Language Testing and Evaluation

    OpenAIRE

    CUNLIFFE, Brenda

    2002-01-01

    This paper briefly reviews the communicative approach to second language teaching and discusses testing students' communicative performance. It is of primary importance that testing should reflect the approach to teaching that has been adopted; hence, this paper includes a brief description of the communicative approach to second language instruction. This approach is then related to testing procedures used to evaluate students' communicative performance.

  12. Advanced Rooftop Control (ARC) Retrofit: Field-Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Weimin; Katipamula, Srinivas; Ngo, Hung; Underhill, Ronald M.; Taasevigen, Danny J.; Lutes, Robert G.

    2013-07-31

    The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

  13. Field analytical techniques for mercury in soils technology evaluation. Topical report, November 1994--March 1997

    Energy Technology Data Exchange (ETDEWEB)

    Solc, J.; Harju, J.A.; Grisanti, A.A.

    1998-02-01

    This report presents the evaluation of the four field analytical techniques for mercury detection in soils, namely (1) an anodic stripping voltametry technique (ASV) developed and tested by General Electric Corporation; (2) a static headspace analysis (SHSA) technique developed and tested by Dr. Ralph Turner of Oak Ridge National Laboratory; (3) the BiMelyze{reg_sign} Mercury Immunoassay (Bio) developed and tested by BioNebraska, Inc.; and (4) a transportable x-ray fluorescence (XRF) instrument/technique developed and tested by Spectrace, Inc.

  14. Numerical evaluation of E-fields induced by body motion near high-field MRI scanner.

    Science.gov (United States)

    Crozier, S; Liu, F

    2004-01-01

    In modern magnetic resonance imaging (MRI), both patients and radiologists are exposed to strong, nonuniform static magnetic fields inside or outside of the scanner, in which the body movement may be able to induce electric currents in tissues which could be possibly harmful. This paper presents theoretical investigations into the spatial distribution of induced E-fields in the human model when moving at various positions around the magnet. The numerical calculations are based on an efficient, quasistatic, finite-difference scheme and an anatomically realistic, full-body, male model. 3D field profiles from an actively-shielded 4 T magnet system are used and the body model projected through the field profile with normalized velocity. The simulation shows that it is possible to induce E-fields/currents near the level of physiological significance under some circumstances and provides insight into the spatial characteristics of the induced fields. The results are easy to extrapolate to very high field strengths for the safety evaluation at a variety of field strengths and motion velocities.

  15. First Field Test of FiDeL the Magnetic Field Description for the LHC

    CERN Document Server

    Bottura, L; Catalan-Lasheras, N; Deniau, L; Di Castro, M; Giovannozzi, M; Hagen, P; Koutchouk, J; Lamont, M; Miles, J; Remondino, V; Sammut, N; Sanfilippo, S; Schmidt, F; Sernelius, D; Strzelczyk, M; Todesco, E; Venturini-Delsolaro, W; Walckiers, L; Wolf, R; Xydi, P

    2009-01-01

    The start-up of the LHC has provided the first field test for the concept, functionality and accuracy of FiDeL, the Field Description for the LHC. FiDeL is primarily a parametric model of the transfer function of the main field integrals generated by the series of magnets in the LHC powering circuits, from main optical elements to high-order harmonic correctors, both superconducting and normal-conducting magnets. In addition, the same framework is used to predict harmonic errors of both static and dynamic nature, and forecast appropriate corrections. In this paper we give a description of the level of detail achieved in the model and the rationale adopted for the LHC start-up. Beam-based measurements have been used for an assessment of the first-shot accuracy in the prediction of the current setting for the main arc magnets. We finally give a list of priority issues to be addressed, and sketch a plan for the preparation of the LHC restart.

  16. Progress in crosswell induction imaging for EOR: field system design and field testing

    Energy Technology Data Exchange (ETDEWEB)

    Kirkendall, B A; Lewis, J P; Hunter, S L; Harben, P E

    1999-03-04

    At Lawrence Livermore National Laboratory (LLNL), we are continuing our effort to develop improved crosswell low-frequency electromagnetic imaging techniques, which are used to map in situ steamflood and waterflood movement during enhanced oil recovery (EOR) operations. Toward this effort, we procured two new borehole-logging field vehicles, and developed and integrated new crosswell electromagnetic transmitter and receiver data acquisition and control systems into these vehicles. We tested this new acquisition system by conducting a suite of background measurements and repeatability experiments at the Richmond Field Station in Richmond, California. Repeatability of a given scan in which the receiver was fixed and the transmitter position was varied over 60 m in 0.2-m increments resulted in amplitude differences of less than 0.6% and phase differences of less than 0.54 deg. Forward modeling produced a resistivity map fully consistent with well log data from the Richmond Field Station. In addition, modeling results suggest (1) that residual high-conductivity saltwater, injected in 1993 and pumped out in 1995, is present at the site and (2) that it has diffused outward from the original target strata. To develop crosswell electromagnetic imaging into a viable commercial product, our future research must be a two-fold approach: (1) improved quantification of system noise through experiments such as ferromagnetic core characterization as a function of temperature, and (2) development of procedures and codes to account for steel-cased hole scenarios.

  17. A test on reactive force fields for the study of silica dimerization reactions

    Energy Technology Data Exchange (ETDEWEB)

    Moqadam, Mahmoud; Riccardi, Enrico; Trinh, Thuat T.; Åstrand, Per-Olof; Erp, Titus S. van, E-mail: titus.van.erp@ntnu.no [Department of Chemistry, Norwegian University of Science and Technology (NTNU), Høgskoleringen 5, Realfagbygget D3-117, 7491 Trondheim (Norway)

    2015-11-14

    We studied silica dimerization reactions in the gas and aqueous phase by density functional theory (DFT) and reactive force fields based on two parameterizations of ReaxFF. For each method (both ReaxFF force fields and DFT), we performed constrained geometry optimizations, which were subsequently evaluated in single point energy calculations using the other two methods. Standard fitting procedures typically compare the force field energies and geometries with those from quantum mechanical data after a geometry optimization. The initial configurations for the force field optimization are usually the minimum energy structures of the ab initio database. Hence, the ab initio method dictates which structures are being examined and force field parameters are being adjusted in order to minimize the differences with the ab initio data. As a result, this approach will not exclude the possibility that the force field predicts stable geometries or low transition states which are realistically very high in energy and, therefore, never considered by the ab initio method. Our analysis reveals the existence of such unphysical geometries even at unreactive conditions where the distance between the reactants is large. To test the effect of these discrepancies, we launched molecular dynamics simulations using DFT and ReaxFF and observed spurious reactions for both ReaxFF force fields. Our results suggest that the standard procedures for parameter fitting need to be improved by a mutual comparative method.

  18. Applicability of the free field Sustained Auditory Attention Ability Test (SAAAT

    Directory of Open Access Journals (Sweden)

    Feniman, Mariza Ribeiro

    2012-01-01

    Full Text Available Introduction: The attention is an underlying neuropsychology function to all the cognitive processes. The auditory deficiency compromises the normal development of the child, modifying diverse auditory abilities, including the attention. Objective: to compare the performance of children in the Test of the Ability of Auditory Attention Support, as for the different forms of application (auricular phones and free field, sort and, application order. Method: 40 children (7 years old voluntary with typical development had participated, divided in two groups: G1 and G2, composites of 20 children each. The application of the THAAS in the G1 if gave first with auricular phones and after that in free field and the G2 the process was inverse. The evaluation consisted in: specific questionnaire, auditory tests and application of the THAAS. Results: It did not have significant difference how much to the sort. For the THAAS with phones, the G1 presented greater amount of errors of carelessness and total punctuation. For the THAAS in field it had a significant difference of the G2 for the monitoring decrease. How much to the application form, the G1 demonstrated a bigger number of errors when it was used phones. The G2 did not demonstrate difference. Conclusion: It had viability in the application of the THAAS in Free Field, being able to be adopted the same used normative values for the conventional way of evaluation.

  19. Evolution of the MIDTAL microarray: the adaption and testing of oligonucleotide 18S and 28S rDNA probes and evaluation of subsequent microarray generations with Prymnesium spp. cultures and field samples.

    Science.gov (United States)

    McCoy, Gary R; Touzet, Nicolas; Fleming, Gerard T A; Raine, Robin

    2015-07-01

    The toxic microalgal species Prymnesium parvum and Prymnesium polylepis are responsible for numerous fish kills causing economic stress on the aquaculture industry and, through the consumption of contaminated shellfish, can potentially impact on human health. Monitoring of toxic phytoplankton is traditionally carried out by light microscopy. However, molecular methods of identification and quantification are becoming more common place. This study documents the optimisation of the novel Microarrays for the Detection of Toxic Algae (MIDTAL) microarray from its initial stages to the final commercial version now available from Microbia Environnement (France). Existing oligonucleotide probes used in whole-cell fluorescent in situ hybridisation (FISH) for Prymnesium species from higher group probes to species-level probes were adapted and tested on the first-generation microarray. The combination and interaction of numerous other probes specific for a whole range of phytoplankton taxa also spotted on the chip surface caused high cross reactivity, resulting in false-positive results on the microarray. The probe sequences were extended for the subsequent second-generation microarray, and further adaptations of the hybridisation protocol and incubation temperatures significantly reduced false-positive readings from the first to the second-generation chip, thereby increasing the specificity of the MIDTAL microarray. Additional refinement of the subsequent third-generation microarray protocols with the addition of a poly-T amino linker to the 5' end of each probe further enhanced the microarray performance but also highlighted the importance of optimising RNA labelling efficiency when testing with natural seawater samples from Killary Harbour, Ireland.

  20. Automated Critical Peak Pricing Field Tests: Program Descriptionand Results

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Xu, Peng

    2006-04-06

    California utilities have been exploring the use of critical peak prices (CPP) to help reduce needle peaks in customer end-use loads. CPP is a form of price-responsive demand response (DR). Recent experience has shown that customers have limited knowledge of how to operate their facilities in order to reduce their electricity costs under CPP (Quantum 2004). While the lack of knowledge about how to develop and implement DR control strategies is a barrier to participation in DR programs like CPP, another barrier is the lack of automation of DR systems. During 2003 and 2004, the PIER Demand Response Research Center (DRRC) conducted a series of tests of fully automated electric demand response (Auto-DR) at 18 facilities. Overall, the average of the site-specific average coincident demand reductions was 8% from a variety of building types and facilities. Many electricity customers have suggested that automation will help them institutionalize their electric demand savings and improve their overall response and DR repeatability. This report focuses on and discusses the specific results of the Automated Critical Peak Pricing (Auto-CPP, a specific type of Auto-DR) tests that took place during 2005, which build on the automated demand response (Auto-DR) research conducted through PIER and the DRRC in 2003 and 2004. The long-term goal of this project is to understand the technical opportunities of automating demand response and to remove technical and market impediments to large-scale implementation of automated demand response (Auto-DR) in buildings and industry. A second goal of this research is to understand and identify best practices for DR strategies and opportunities. The specific objectives of the Automated Critical Peak Pricing test were as follows: (1) Demonstrate how an automated notification system for critical peak pricing can be used in large commercial facilities for demand response (DR). (2) Evaluate effectiveness of such a system. (3) Determine how customers

  1. Automated Critical Peak Pricing Field Tests: Program Descriptionand Results

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Xu, Peng

    2006-04-06

    California utilities have been exploring the use of critical peak prices (CPP) to help reduce needle peaks in customer end-use loads. CPP is a form of price-responsive demand response (DR). Recent experience has shown that customers have limited knowledge of how to operate their facilities in order to reduce their electricity costs under CPP (Quantum 2004). While the lack of knowledge about how to develop and implement DR control strategies is a barrier to participation in DR programs like CPP, another barrier is the lack of automation of DR systems. During 2003 and 2004, the PIER Demand Response Research Center (DRRC) conducted a series of tests of fully automated electric demand response (Auto-DR) at 18 facilities. Overall, the average of the site-specific average coincident demand reductions was 8% from a variety of building types and facilities. Many electricity customers have suggested that automation will help them institutionalize their electric demand savings and improve their overall response and DR repeatability. This report focuses on and discusses the specific results of the Automated Critical Peak Pricing (Auto-CPP, a specific type of Auto-DR) tests that took place during 2005, which build on the automated demand response (Auto-DR) research conducted through PIER and the DRRC in 2003 and 2004. The long-term goal of this project is to understand the technical opportunities of automating demand response and to remove technical and market impediments to large-scale implementation of automated demand response (Auto-DR) in buildings and industry. A second goal of this research is to understand and identify best practices for DR strategies and opportunities. The specific objectives of the Automated Critical Peak Pricing test were as follows: (1) Demonstrate how an automated notification system for critical peak pricing can be used in large commercial facilities for demand response (DR). (2) Evaluate effectiveness of such a system. (3) Determine how customers

  2. Comprehensive evaluation of attitude and orbit estimation using real earth magnetic field data

    Science.gov (United States)

    Deutschmann, Julie; Bar-Itzhack, Itzhack

    1997-01-01

    A single, augmented extended Kalman filter (EKF) which simultaneously and autonomously estimates spacecraft attitude and orbit was developed and tested with simulated and real magnetometer and rate data. Since the earth's magnetic field is a function of time and position, and since time is accurately known, the differences between the computed and measured magnetic field components, as measured by the magnetometers throughout the entire spacecraft's orbit, are a function of orbit and attitude errors. These differences can be used to estimate the orbit and attitude. The test results of the EKF with magnetometer and gyro data from three NASA satellites are presented and evaluated.

  3. RAPID TEST METHOD FOR EVALUATION OF ANTIFREEZE ADDITIVE EFFICIENCY

    Directory of Open Access Journals (Sweden)

    S. V. Gushchin

    2015-01-01

    Full Text Available Usage of chemical additives while executing concrete works at negative temperatures is considered as a convenient and economical method. Range of the used antifreeze additives is rather wide. A great number of new additives are advertised but their characteristics have not been practically studied. Evaluation of the antifreeze additive efficiency is unfortunately rather long process and it does not provide comprehensive data on concrete structure formation processes. Due to this development of rapid and comprehensive methodology for construction companies is urgently required.Freezing processes of antifreeze additive aqueous solutions and hardening of cement paste with them have been investigated in the paper. The paper proposes a methodology for determination of freezing point for aqueous solutions of chemical additives of various applications. Identity of  freezing point for a chemical additive aqueous solution and cement paste with an equal concentration of the additive in the paste pore fluid has been determined while taking  calcium nitrate and sodium formate additives as an example. The paper demonstrates the possibility to evaluate efficiency of antifreeze additive action on the basis of kinetics in temperature changes of the cement paste with additives by its consecutive freezing and defrosting.  A methodology for operational evaluation in the field of chemical additive application for concreting items at negative temperatures has been offered in the paper.  The methodology does not require  deficient and expensive test-equipment. It can be applied at ordinary construction companies and it is comprehensible for personnel of low-qualification.  The paper shows the possibility to develop an original methodology for designing concrete structure which is based on operating efficiency determinations  for single and integrated antifreeze additives.

  4. A magnetic field exposure facility for evaluation of animal carcinogenicity.

    Science.gov (United States)

    Maruvada, P S; Harvey, S M; Jutras, P; Goulet, D; Mandeville, R

    2000-09-01

    Several animal studies have been carried out at the Institut Armand Frappier (IAF) to determine whether chronic exposure to 60 Hz linearly polarized sinusoidal magnetic fields might increase the risk of cancer development of female Fisher rats. The magnetic field exposure facility was developed to meet the requirements of the study protocol for chronic exposure of large number of animals to field intensities of sham < 0.2 microT, 2 microT, 20 microT, 200 microT, and 2000 microT. At each exposure level, including sham, the animals are distributed in a group of four exposure units. Each exposure unit contains two exposure volumes having uniform distribution of magnetic fields for the animals, while the magnetic field external to the unit falls off rapidly due to the "figure-eight" coil topography used. A program of "shake down" tests, followed by verification and calibration of the exposure facility, was carried out prior to starting the animal experiments. Continuous monitoring of the magnetic field and other environmental parameters was an important part in the overall quality assurance program adopted.

  5. Field test of radioactive high efficiency filter and filter exchange techniques of fuel cycle examination facility

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Yong Hwa; Lee, Hyung Kwon; Chun, Young Bum; Park, Dae Gyu; Ahn, Sang Bok; Chu, Yong Sun; Kim, Eun Ka

    1997-12-01

    The development of high efficiency filter was started to protect human beings from the contamination of radioactive particles, toxic gases and bacillus, and its gradual performance increment led to the fabrication of Ultra Low Penetration Air Filter (ULPA) today. The application field of ULPA has been spread not only to the air conditioning of nuclear power facilities, semiconductor industries, life science, optics, medical care and general facilities but also to the core of ultra-precision facilities. Periodic performance test on the filters is essential to extend its life-time through effective maintenance. Especially, the bank test on HEPA filter of nuclear facilities handling radioactive materials is required for environmental safety. Nowadays, the bank test technology has been reached to the utilization of a minimized portable detecting instruments and the evaluation techniques can provide high confidence in the area of particle distribution and leakage test efficiency. (author). 16 refs., 13 tabs., 14 figs.

  6. Evolving test-fields in a black-hole geometry

    CERN Document Server

    Andersson, N

    1997-01-01

    We consider the initial value problem for a massless scalar field in the Schwarzschild geometry. When constructed using a complex-frequency approach the necessary Green's function splits into three components. We discuss all of these in some detail: 1) The contribution from the singularities (the quasinormal modes of the black hole) is approximated and the mode-sum is demonstrated to converge after a certain well defined time in the evolution. A dynamic description of the mode-excitation is introduced and tested. 2) It is shown how a straightforward low-frequency approximation to the integral along the branch cut in the black-hole Green's function leads to the anticipated power-law fall off at very late times. We also calculate higher order corrections to this tail and show that they provide an important complement to the leading order. 3) The high-frequency problem is also considered. We demonstrate that the combination of the obtained approximations for the quasinormal modes and the power-law tail provide a...

  7. Evolving test fields in a black-hole geometry

    Science.gov (United States)

    Andersson, Nils

    1997-01-01

    We consider the initial value problem for a massless scalar field in the Schwarzschild geometry. When constructed using a complex-frequency approach the necessary Green's function splits into three components. We discuss all of these in some detail. (1) The contribution from the singularities (the quasinormal modes of the black hole) is approximated and the mode sum is demonstrated to converge after a certain well-defined time in the evolution. A dynamic description of the mode excitation is introduced and tested. (2) It is shown how a straightforward low-frequency approximation to the integral along the branch cut in the black-hole Green's function leads to the anticipated power-law falloff at very late times. We also calculate higher order corrections to this tail and show that they provide an important complement to the leading order. (3) The high-frequency problem is also considered. We demonstrate that the combination of the obtained approximations for the quasinormal modes and the power-law tail provide a complete description of the evolution at late times. Problems that arise (in the complex-frequency picture) for early times are also discussed, as is the fact that many of the presented results generalize to, for example, Kerr black holes.

  8. Field test of a post-closure radiation monitor

    Energy Technology Data Exchange (ETDEWEB)

    Reed, S.E. [Babcock & Wilcox, Alliance, OH (United States); Christy, C.E. [Department of Energy, Morgantown, WV (United States); Heath, R.E. [FERMCO, Cincinnati, OH (United States)

    1995-10-01

    The DOE is conducting remedial actions at many sites contaminated with radioactive materials. After closure of these sites, long-term subsurface monitoring is typically required by law. This monitoring is generally labor intensive and expensive using conventional sampling and analysis techniques. The U.S. Department of Energy`s Morgantown Energy Technology Center (METC) has contracted with Babcock and Wilcox to develop a Long-Term Post-Closure Radiation Monitoring System (LPRMS) to reduce these monitoring costs. The system designed in Phase I of this development program monitors gamma radiation using a subsurface cesium iodide scintillator coupled to above-ground detection electronics using optical waveguide. The radiation probe can be installed to depths up to 50 meters using cone penetrometer techniques, and requires no downhole electrical power. Multiplexing, data logging and analysis are performed at a central location. A prototype LPRMS probe was built, and B&W and FERMCO field tested this monitoring probe at the Fernald Environmental Management Project in the fall of 1994 with funding from the DOE`s Office of Technology Development (EM-50) through METC. The system was used measure soil and water with known uranium contamination levels, both in drums and in situ depths up to 3 meters. For comparison purposes measurements were also performed using a more conventional survey probe with a sodium iodide scintillator directly butt-coupled to detection electronics.

  9. Field test of thermoelectric generating system at Komatsu plant

    Energy Technology Data Exchange (ETDEWEB)

    Kaibe, Hiromasa T.; Fujimoto, Sinichi; Mizukami, Hiroyuki; Morimoto, Shigeo [Komatsu Ltd., Kanagawa (Japan)

    2011-07-01

    At the end of October 2009, Komatsu Ltd. started a field test of the thermoelectric generation (TEG) system at a carburizing facility of Awazu plant. Residual carburizing gas based on such as CO, N and H{sub 2} is burned resulting that 20-30 kW range of flame constantly heats up the hot side of TEG. 16 of the Bi-Te thermo-modules, which were separated into 4 groups, were employed, each of which has a size of 50 by 50 by 4.2 mm{sup 3} and can generate better than 25 W under the circumstance of 280 C and 30 C of hot side and cold side temperature, respectively. Each module has a single booster-type DC/DC converter controlled by one chip computer and Maximum Power point Tracking (MPPT) was well facilitated to search for the maximum output power depending on the hot and cold side temperature. The electric output power from the four modules is summed up to charge a single lead storage battery (GS Yuasa Corp. 12V-65Ah) and then through a DC/AC inverter electricity goes to fluorescent light tubes inside the factory. Typically from 4 groups 200 W can be generated and 170 W is delivered to the batteries. (orig.)

  10. The Savannah River Technology Center environmental monitoring field test platform

    Energy Technology Data Exchange (ETDEWEB)

    Rossabi, J.

    1993-03-05

    Nearly all industrial facilities have been responsible for introducing synthetic chemicals into the environment. The Savannah River Site is no exception. Several areas at the site have been contaminated by chlorinated volatile organic chemicals. Because of the persistence and refractory nature of these contaminants, a complete clean up of the site will take many years. A major focus of the mission of the Environmental Sciences Section of the Savannah River Technology Center is to develop better, faster, and less expensive methods for characterizing, monitoring, and remediating the subsurface. These new methods can then be applied directly at the Savannah River Site and at other contaminated areas in the United States and throughout the world. The Environmental Sciences Section has hosted field testing of many different monitoring technologies over the past two years primarily as a result of the Integrated Demonstration Program sponsored by the Department of Energy`s Office of Technology Development. This paper provides an overview of some of the technologies that have been demonstrated at the site and briefly discusses the applicability of these techniques.

  11. Numerical evaluation of the tensor bispectrum in two field inflation

    CERN Document Server

    Raveendran, Rathul Nath

    2016-01-01

    We evaluate the dimensionless non-Gaussianity parameter $h_{_{\\rm NL}}$, that characterizes the amplitude of the tensor bispectrum, numerically for a class of two field inflationary models such as double inflation, hybrid inflation and aligned natural inflation. We compare the numerical results with the slow roll results which can be obtained analytically. In the context of double inflation, we also investigate the effects on $h_{_{\\rm NL}}$ due to curved trajectories in the field space. We explicitly examine the validity of the consistency relation governing the tensor bispectrum in the squeezed limit. Lastly, we discuss the contribution to $h_{_{\\rm NL}}$ due to the epoch of preheating in two field models.

  12. A simple test for thermomechanical evaluation of ceramic fibers

    Science.gov (United States)

    Morscher, Gregory N.; Dicarlo, James A.

    1992-01-01

    A simple bend stress relaxation (BSR) test was developed to measure the creep related properties of ceramic fibers and whiskers. The test was applied to a variety of commercial and developmental Si based fibers to demonstrate capabilities and to evaluate the relative creep resistance of the fibers at 1200 to 1400 C. The implications of these results and the advantages of the BSR test over typical tensile creep tests are discussed.

  13. On multiplying methods in the field of research evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Derrick, G.; Molas-Gallart, J.; De Rijcke, S.; Meijer, I.; Van der Weijden, I.; Wouters, P.

    2016-07-01

    This special session forms part of a larger program aimed at the multiplication and integration of methodological approaches in the research evaluation and innovation policy field. The session builds on previous initiatives by Gemma Derrick and colleagues at CWTS, INGENIO, the Rathenau Instituut and SPRU, exploring the advantages of qualitative methodological tools at the STI/ENID conference in Lugano, and an international workshop in London in October 2015. The program is highly topical: the research evaluation field is currently reconsidering its methodological foundations in light of new research questions arising from policy initiatives regarding a) the move toward open science; b) a reconceptualization of research excellence to include societal relevance; c) diversification of academic careers, and d) the search for indicators showcasing responsible research behavior and innovation. This new special session at STI2016 will advance and broaden the scope of previous initiatives by building bridges between cutting edge research involving quantitative, qualitative, and mixed methodological research designs. Bringing together leading experts and promising researchers with distinctive methodological skill-sets, the session will demonstrate the advantages of cross-fertilization between ‘core’ and ‘peripheral’ methodological approaches for the research evaluation and science indicators field. (Author)

  14. Overall test evaluation based on trajectory tracking data

    Institute of Scientific and Technical Information of China (English)

    王正明; 段晓君

    2001-01-01

    According to the trajectory characteristics of ballistic missile, a reduced parameter model is constructed based on difference between telemetry trajectory and trajectory tracking data. By virtue of Bayesian theory and data fusion technique, a new test evaluation method is put forth, which can make full use of the trajectory tracking data, shooting range test data and relevant information. Since the impact point can be derived from trajectory difference and its kinetic characteristics, evaluation of the impact point is a special case of this method. The accurate evaluation and the accuracy of evaluation results can be provided by the new method.

  15. Field-testing of the rapid assessment of disability questionnaire.

    Science.gov (United States)

    Marella, Manjula; Busija, Lucy; Islam, Fakir M Amirul; Devine, Alexandra; Fotis, Kathy; Baker, Sally M; Sprunt, Beth; Edmonds, Tanya J; Huq, Nafisa Lira; Cama, Anaseini; Keeffe, Jill E

    2014-09-01

    The Rapid Assessment of Disability (RAD) questionnaire measures the magnitude and impact of disability and aims to inform the design of disability inclusive development programs. This paper reports the psychometric evaluation of the RAD. The initial version of the RAD comprised five sections: 1) demographics, 2) functioning, 3) rights awareness, 4) well-being, and 5) access to the community. Item functioning and construct validity were assessed in a population-based study in Bangladesh. Data were analysed using descriptive statistics (sections 2 and 5) and Rasch modelling (sections 3 and 4). A subsequent case-control study in Fiji tested the refined questionnaire in a cross-cultural setting and assessed the sensitivity and specificity of the RAD section 2 to identify people with disability. 2,057 adults took part in the study (1,855 in Bangladesh and 202 in Fiji). The prevalence of disability estimated using RAD section 2 in Bangladesh was 10.5% (95% CI 8.8-12.2), with satisfactory sensitivity and specificity (62.4% and 81.2%, respectively). Section 3 exhibited multidimensionality and poor differentiation between levels of rights awareness in both Bangladesh (person separation index [PSI] = 0.71) and Fiji (PSI = 0.0), and was unable to distinguish between people with and without disability (Bangladesh p = 0.786, Fiji p = 0.43). This section was subsequently removed from the questionnaire pending re-development. Section 4 had good ability to differentiate between levels of well-being (PSI = 0.82). In both countries, people with disability had significantly worse well-being scores than people without disability (p RAD. Information from the questionnaire can be used to inform and evaluate disability inclusive development programs.

  16. Evaluation of Mapping Methodologies at a Legacy Test Site

    Science.gov (United States)

    Sussman, A. J.; Schultz-Fellenz, E. S.; Roback, R. C.; Kelley, R. E.; Drellack, S.; Reed, D.; Miller, E.; Cooper, D. I.; Sandoval, M.; Wang, R.

    2013-12-01

    On June 12th, 1985, a nuclear test with an announced yield between 20-150kt was detonated in rhyolitic lava in a vertical emplacement borehole at a depth of 608m below the surface. This test did not collapse to the surface and form a crater, but rather resulted in a subsurface collapse with more subtle surface expressions of deformation, providing an opportunity to evaluate the site using a number of surface mapping methodologies. The site was investigated over a two-year time span by several mapping teams. In order to determine the most time efficient and accurate approach for mapping post-shot surface features at a legacy test site, a number of different techniques were employed. The site was initially divided into four quarters, with teams applying various methodologies, techniques, and instrumentations to each quarter. Early methods included transect lines and site gridding with a Brunton pocket transit, flagging tape, measuring tape, and stakes; surveying using a hand-held personal GPS to locate observed features with an accuracy of × 5-10m; and extensive photo-documentation. More recent methods have incorporated the use of near survey grade GPS devices to allow careful location and mapping of surface features. Initially, gridding was employed along with the high resolution GPS surveys, but this was found to be time consuming and of little observational value. Raw visual observation (VOB) data included GPS coordinates for artifacts or features of interest, field notes, and photographs. A categorization system was used to organize the myriad of items, in order to aid in database searches and for visual presentation of findings. The collected data set was imported into a geographic information system (GIS) as points, lines, or polygons and overlain onto a digital color orthophoto map of the test site. Once these data were mapped, spectral data were collected using a high resolution field spectrometer. In addition to geo-locating the field observations with 10cm

  17. Testing the Visual Soil Assessment tool on Estonian farm fields

    Science.gov (United States)

    Reintam, Endla; Are, Mihkel; Selge, Are

    2017-04-01

    Soil quality estimation plays important role in decision making on farm as well on policy level. Sustaining the production ability and good health of the soil the chemical, physical and biological indicators should be taken into account. The system to use soil chemical parameters is usually quite well established in most European counties, including Estonia. However, measuring soil physical properties, such bulk density, porosity, penetration resistance, structural stability ect is time consuming, needs special tools and is highly weather dependent. In that reason these parameters are excluded from controllable quality parameters in policy in Estonia. Within the project "Interactive Soil Quality Assessment in Europe and China for Agricultural Productivity and Environmental Resilience" (iSQAPER) the visual soil assessment (VSA) tool was developed for easy detection of soil quality as well the different soil friendly agricultural management practices (AMP) were detected. The aim of current study was to test the VSA tool on Estonian farm fields under different management practices and compare the results with laboratory measurements. The main focus was set on soil physical parameters. Next to the VSA, the undisturbed soil samples were collected from the depth of 5-10 cm and 25-30 cm. The study revealed that results of a visually assessed soil physical parameters, such a soil structure, soil structural stability, soil porosity, presence of tillage pan, were confirmed by laboratory measurements in most cases. Soil water stable structure measurement on field (on 1 cm2 net in one 1 l box with 4-6 cm air dry clods for 5-10 min) underestimated very well structured soil on grassland and overestimated the structure aggregates stability of compacted soil. The slightly better soil quality was detected under no-tillage compared to ploughed soils. However, the ploughed soil got higher quality points compared with minimum tillage. The slurry application (organic manuring) had

  18. Evaluation of a laboratory test to detect resistance to closantel in Haemonchus contortus.

    Science.gov (United States)

    Lloyd, J B; Fitzgibbon, C C; Barchia, I

    2000-10-01

    To evaluate a laboratory test for closantel resistance in Haemonchus contortus. Field isolates of H contortus, known to be resistant to closantel, were tested in the assay. In addition, mixtures of closantel-susceptible and closantel-resistant laboratory reference strains were tested to develop a method of predicting the proportion of resistant worms in a sample from the field. The assay correctly identified as resistant all of the closantel-resistant field isolates of H contortus. It also identified one isolate with an in vivo efficacy of 98% as having emerging resistance. Testing of the mixtures of laboratory reference strains revealed that an isolate would be classified as resistant when it consists of about 25% or more resistant worms. Test samples that are not fully susceptible yet contain less than 25% resistant worms may be classified as emerging resistance. The in vitro migration assay is a sensitive method of detecting closantel resistance in H contortus.

  19. Evaluation of the field size in dental diagnostic radiology system

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, P.S.; Potiens, M.P.A. [Instituto de Pesquisas Energeticas e Nucleares, Sao Paulo (Brazil)

    2006-07-01

    In this work the field size of a dental X rays machine was evaluated considering the recommendation of the Brazilian Health Ministry Regulation 453 which established basic lines of radiological protection in medical and dental diagnostic radiology. The diameter of the field should not be superior to 6 cm in the localized end point, limiting the radiated area and protecting the head-neck region. The measurements were carried out in a dental X rays machine, Dabi Atlante, model Spectro 70X Seletronic. For the field size or useful beam determination, the intra-oral films were positioned on a plain surface to be exposed in four stages and two focus-film distances (FFD), 20 cm and 27.5 cm: 1) with spacer cone; 2) without spacer cone; 3) with spacer cone and film-holding device; 4) without spacer cone and film-holding device. The results show that the diameter of the field size is satisfactory only for FFD = 20 cm. When the film-holding device is used, which is recommended by the Regulation 453, item 5.8 d(ii), the diameter of the field size exceeds the maximum recommended value of 6 cm. (authors)

  20. Reasearch and Evaluation of Electromagnetic Fields of Refrigerators

    Directory of Open Access Journals (Sweden)

    Pranas Baltrėnas

    2013-12-01

    Full Text Available The use of refrigerators causes the occurence of electromagnetic fields that are invisible and intangible, which therefore makes difficulties in protecting ourselves from them. A refrigerator is an irreplaceable item in domestic household and thus can be hardly ignored by a modern way of human life. In order to preserve the characteristics of products, the refrigerator must operate continuously (24 hrs a day, regardless of the time of the year. This results in a huge increase in electricity consumption, which leads to energy consumption related pollution of the environment emitting CO2 gas. On these grounds, it is necessary to assess electromagnetic fields created by the refrigerator. Studies on electromagnetic fields produced by refrigerators were conducted in domestic premises where people spent a significant part of the day. For comparison purposes, five different power refrigerators were chosen (1 – 0.20 kW; 2 – 0.25 kW; 3 – 0.30 kW; 4 – 0.35 kW; 5 – 0.40 kW. The obtained results, according to the parameters of their electromagnetic fields, were presented in graphs and charts and showed that the values of electric and magnetic intensity of refrigerators depended on the distance and the power of the refrigerator. The conducted research also disclosed that none of tested refrigerators exceeded the permissible limits of electromagnetic fields.Article in Lithuanian

  1. Diagnosis and Tests: Evaluating a Fall or Risk of Falling

    Science.gov (United States)

    ... Balance Problems Diabetes Fainting (Syncope) Foot Problems Fractures Osteoporosis Physical Activity Prevention Sleep Problems Stroke Join our e- ... medications reveals possible toxic levels Detailed memory testing Physical therapy assessment A home safety evaluation. Updated: March 2012 ...

  2. Evaluation criteria and test methods for electrochromic windows

    Energy Technology Data Exchange (ETDEWEB)

    Czanderna, A.W. (Solar Energy Research Inst., Golden, CO (USA)); Lampert, C.M. (Lawrence Berkeley Lab., CA (USA))

    1990-07-01

    Report summarizes the test methods used for evaluating electrochromic (EC) windows, and summarizes what is known about degradation of their performance, and recommends methods and procedures for advancing EC windows for buildings applications. 77 refs., 13 figs., 6 tabs.

  3. Evaluation of carbohydrate molecular mechanical force fields by quantum mechanical calculations

    DEFF Research Database (Denmark)

    Hemmingsen, Lars Bo Stegeager; Madsen, D.E.; Esbensen, A.L.

    2004-01-01

    A quantitative evaluation of 20 second-generation carbohydrate force fields was carried out using ab initio and density functional methods. Geometry-optimized structures (B3LYP/6-31G(d)) and relative energies using augmented correlation consistent basis sets were calculated in gas phase...... for monosaccharide carbohydrate benchmark systems. Selected results are: (i) The interaction energy of the alpha-D-alucopyranose-H2O heterodimer is estimated to be 4.9 kcal/mol, using a composite method including terms at highly correlated (CCSD(T)) level. Most molecular mechanics force fields are in error......-generation carbohydrate force fields. No single force field is consistently better than the others for all the test cases. A statistical assessment of the performance of the force fields indicates that CHEAT(95), CFF, certain versions of Amber and of MM3 have the best overall performance, for these gas phase...

  4. A Study on College English Test Construction and Evaluation

    Institute of Scientific and Technical Information of China (English)

    黄雅彬

    2008-01-01

    Testing is a universal feature of social life.Throughout history people have been put to the test to prove their capabilities or to establish qualifications.Language tests play an important role in many people’s lives,acting as gateways at important transitional moments in education.The college English test paper was reviewed and checked against the test specifications to see its content coverage and representative.To evaluate the test,this includes item analysis,descriptive statistics,validity,and what we see as the strong points and the weaknesses of the test based on the analysis and the testing conditions,both of which provided validity evidence.In order to gather details of the test items,item analysis was done to find out the difficulty and discrimination of each item and identify misfit items for further discussion.

  5. Influence of the magnetic field profile on ITER conductor testing

    NARCIS (Netherlands)

    Nijhuis, A.; Ilyin, Y.; Kate, ten H.H.J.

    2006-01-01

    We performed simulations with the numerical CUDI-CICC code on a typical short ITER (International Thermonuclear Experimental Reactor) conductor test sample of dual leg configuration, as usually tested in the SULTAN test facility, and made a comparison with the new EFDA-Dipole test facility offering

  6. Table 1. Summary of Field Testing and Measurement Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Key performance parameters measured during the field demonstration such as lining thickness, compressive strength, Flexural Strength, Modulus of Elasticity, bond...

  7. Brick Paving Systems in Expeditionary Environments: Field Testing

    Science.gov (United States)

    2012-07-01

    Dynamic Cone Penetrometer (DCP) tests were conducted on each test item as an alternative strength measurement to the in situ CBR tests conducted on the...many passes of the C-17 load before failure. Between 20 and 40 passes, the majority of the bricks in the wheel path began to break or shatter . Figures...American Society for Testing and Materials. 2003. Standard test method for use of the dynamic cone penetrometer in shallow pavement applications

  8. 在役铁磁性钢管远场涡流检测常用标准的分析和比较%Evaluation and Comparison of Standards for Examination of In-service Ferromagnetic Steel Tubes Using Remote Field Testing

    Institute of Scientific and Technical Information of China (English)

    倪进飞; 黎华; 范贤振; 马括

    2013-01-01

    介绍了远场涡流检测技术的发展历程和基本原理,从适用范围、检测人员和检测机构资质的规定、检测系统、对比试样管、灵敏度调节和辅助检测要求等方面对在役铁磁性钢管远场涡流检测三个常用的现行标准进行了分析和比较,并对该技术的标准化工作提出建议.%The history and basic principles of remote field eddy current testing(RFT) were briefly introduced. Three Standards for examination of in-service ferromagnetic steel tubes using this technique were evaluated and compared in six aspects. Some suggestions for standardization of RFT were also given.

  9. Isokinetic knee joint evaluation in track and field events.

    Science.gov (United States)

    Deli, Chariklia K; Paschalis, Vassilis; Theodorou, Anastasios A; Nikolaidis, Michalis G; Jamurtas, Athanasios Z; Koutedakis, Yiannis

    2011-09-01

    The purpose of this study was to evaluate maximal torque of the knee flexors and extensors, flexor/extensor ratios, and maximal torque differences between the 2 lower extremities in young track and field athletes. Forty male track and field athletes 13-17 years old and 20 male nonathletes of the same age participated in the study. Athletes were divided into 4 groups according to their age and event (12 runners and 10 jumpers 13-15 years old, 12 runners and 6 jumpers 16-17 years old) and nonathletes into 2 groups of the same age. Maximal torque evaluation of knee flexors and extensors was performed on an isokinetic dynamometer at 60°·s(-1). At the age of 16-17 years, jumpers exhibited higher strength values at extension than did runners and nonathletes, whereas at the age of 13-15 years, no significant differences were found between events. Younger athletes were weaker than older athletes at flexion. Runners and jumpers were stronger than nonathletes in all relative peak torque parameters. Nonathletes exhibited a higher flexor/extensor ratio compared with runners and jumpers. Strength imbalance in athletes was found between the 2 lower extremities in knee flexors and extensors and also at flexor/extensor ratio of the same extremity. Young track and field athletes exhibit strength imbalances that could reduce their athletic performance, and specific strength training for the weak extremity may be needed.

  10. Evaluation of the hydrologic source term from underground nuclear tests in Frenchman Flat at the Nevada Test Site: The Cambric test

    Energy Technology Data Exchange (ETDEWEB)

    Bourcier, W L; Bruton, C J; Carle, S F; Kersting, A B; Pawloski, G A; Rard, J A; Shumaker, D E; Smith, D K; Tompson, A F

    1999-03-23

    The objectives of this project are to develop and apply a modeling frame- work to quantitatively evaluate the nature and extent of radionuclide migration within the immediate, near field environment about an underground nuclear test. Specifically, it will involve evaluation of ² The speciation and abundance of radionuclides that are introduced into groundwater as aqueous species or colloids, and ² The rate and extent of radionuclide movement, dilution, and reaction in groundwater surrounding the working point of a test. To be clear, interest will only be focused on processes that have occurred well after the nuclear test, as opposed to the more dynamic processes that take place during or immediately after detonation. The meaning of "near field" in this case will loosely refer to a volume of diameter 4-8 Rc, centered on the working point and chimney of the test, where Rc is the radius of the blast cavity. For a given nuclear test, this information will collectively comprise the test's "hydrologic source term". This work relies on and is being supported by existing data, analyses, and interpretations that have been made at the Nevada Test Site (NTS) during the American nuclear test program and previous and ongoing studies related to radionuclide migration in the subsurface (Kersting, 1996).

  11. The Test and Evaluation of Unmanned and Autonomous Systems

    Science.gov (United States)

    2008-12-01

    SUBTITLE The Test and Evaluation of Unmanned and Autonomous Systems 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d...adaptive behavior. Only by instituting positive feedback and negative feedback test frameworks, can these systems be sustained through intergenerational

  12. DITCM roadside facilities for cooperative systems testing and evaluation

    NARCIS (Netherlands)

    Passchier, I.; Netten, B.D.; Wedemeijer, H.; Maas, S.M.P.; Leeuwen, C.J. van; Schackmann, P.P.M.

    2013-01-01

    Cooperative systems are being developed for large scale deployment in the near future. Validation of the performance of cooperative systems, and evaluation of the impact of cooperative applications is crucial before large scale deployment can proceed. The DITCM test site facilitates testing, evaluat

  13. Remote control circuit breaker evaluation testing. [for space shuttles

    Science.gov (United States)

    Bemko, L. M.

    1974-01-01

    Engineering evaluation tests were performed on several models/types of remote control circuit breakers marketed in an attempt to gain some insight into their potential suitability for use on the space shuttle vehicle. Tests included the measurement of several electrical and operational performance parameters under laboratory ambient, space simulation, acceleration and vibration environmental conditions.

  14. Remote control circuit breaker evaluation testing. [for space shuttles

    Science.gov (United States)

    Bemko, L. M.

    1974-01-01

    Engineering evaluation tests were performed on several models/types of remote control circuit breakers marketed in an attempt to gain some insight into their potential suitability for use on the space shuttle vehicle. Tests included the measurement of several electrical and operational performance parameters under laboratory ambient, space simulation, acceleration and vibration environmental conditions.

  15. Developing a Test Collection for the Evaluation of Integrated Search

    DEFF Research Database (Denmark)

    Lykke, Marianne; Larsen, Birger; Lund, Haakon

    2010-01-01

    he poster discusses the characteristics needed in an information retrieval (IR) test collection to facilitate the evaluation of integrated search, i.e. search across a range of different sources but with one search box and one ranked result list, and describes and analyses a new test collection...

  16. An Evaluation of "Dialogue Completion" in English Testing

    Institute of Scientific and Technical Information of China (English)

    邵阳

    2011-01-01

    To evaluate the validity of "dialogue completion" item in the language testing,this article explores three contradictions by analyzing aspects of its characters,content,validity and reliability.The finding is that "dialogue completion" patten has unpredicted answer and should be avoided in the testing as much as possible.

  17. Counter unmanned aerial system testing and evaluation methodology

    Science.gov (United States)

    Kouhestani, C.; Woo, B.; Birch, G.

    2017-05-01

    Unmanned aerial systems (UAS) are increasing in flight times, ease of use, and payload sizes. Detection, classification, tracking, and neutralization of UAS is a necessary capability for infrastructure and facility protection. We discuss test and evaluation methodology developed at Sandia National Laboratories to establish a consistent, defendable, and unbiased means for evaluating counter unmanned aerial system (CUAS) technologies. The test approach described identifies test strategies, performance metrics, UAS types tested, key variables, and the necessary data analysis to accurately quantify the capabilities of CUAS technologies. The tests conducted, as defined by this approach, will allow for the determination of quantifiable limitations, strengths, and weaknesses in terms of detection, tracking, classification, and neutralization. Communicating the results of this testing in such a manner informs decisions by government sponsors and stakeholders that can be used to guide future investments and inform procurement, deployment, and advancement of such systems into their specific venues.

  18. Field Test Design Simulations of Pore-Water Extraction for the SX Tank Farm

    Energy Technology Data Exchange (ETDEWEB)

    Truex, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Oostrom, Martinus [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-09-01

    A proof of principle test of pore water extraction is being performed by Washington River Protection Solutions for the U.S. Department of Energy, Office of River Protection. This test is being conducted to meet the requirements of Hanford Federal Facility Agreement and Consent Order (HFFACO) (Ecology et al. 1989) Milestone M 045-20, and is described in RPP-PLAN-53808, 200 West Area Tank Farms Interim Measures Investigation Work Plan. To support design of this test, numerical simulations were conducted to help define equipment and operational parameters. The modeling effort builds from information collected in laboratory studies and from field characterization information collected at the test site near the Hanford Site 241-SX Tank Farm. Numerical simulations were used to evaluate pore-water extraction performance as a function of the test site properties and for the type of extraction well configuration that can be constructed using the direct-push installation technique. Output of simulations included rates of water and soil-gas production as a function of operational conditions for use in supporting field equipment design. The simulations also investigated the impact of subsurface heterogeneities in sediment properties and moisture distribution on pore-water extraction performance. Phenomena near the extraction well were also investigated because of their importance for pore-water extraction performance.

  19. Low-cost, smartphone based frequency doubling technology visual field testing using virtual reality (Conference Presentation)

    Science.gov (United States)

    Alawa, Karam A.; Sayed, Mohamed; Arboleda, Alejandro; Durkee, Heather A.; Aguilar, Mariela C.; Lee, Richard K.

    2017-02-01

    Glaucoma is the leading cause of irreversible blindness worldwide. Due to its wide prevalence, effective screening tools are necessary. The purpose of this project is to design and evaluate a system that enables portable, cost effective, smartphone based visual field screening based on frequency doubling technology. The system is comprised of an Android smartphone to display frequency doubling stimuli and handle processing, a Bluetooth remote for user input, and a virtual reality headset to simulate the exam. The LG Nexus 5 smartphone and BoboVR Z3 virtual reality headset were used for their screen size and lens configuration, respectively. The system is capable of running the C-20, N-30, 24-2, and 30-2 testing patterns. Unlike the existing system, the smartphone FDT tests both eyes concurrently by showing the same background to both eyes but only displaying the stimulus to one eye at a time. Both the Humphrey Zeiss FDT and the smartphone FDT were tested on five subjects without a history of ocular disease with the C-20 testing pattern. The smartphone FDT successfully produced frequency doubling stimuli at the correct spatial and temporal frequency. Subjects could not tell which eye was being tested. All five subjects preferred the smartphone FDT to the Humphrey Zeiss FDT due to comfort and ease of use. The smartphone FDT is a low-cost, portable visual field screening device that can be used as a screening tool for glaucoma.

  20. Evaluation of Depth of Field for depth perception in DVR

    KAUST Repository

    Grosset, A.V.Pascal

    2013-02-01

    In this paper we present a user study on the use of Depth of Field for depth perception in Direct Volume Rendering. Direct Volume Rendering with Phong shading and perspective projection is used as the baseline. Depth of Field is then added to see its impact on the correct perception of ordinal depth. Accuracy and response time are used as the metrics to evaluate the usefulness of Depth of Field. The onsite user study has two parts: static and dynamic. Eye tracking is used to monitor the gaze of the subjects. From our results we see that though Depth of Field does not act as a proper depth cue in all conditions, it can be used to reinforce the perception of which feature is in front of the other. The best results (high accuracy & fast response time) for correct perception of ordinal depth occurs when the front feature (out of the two features users were to choose from) is in focus and perspective projection is used. © 2013 IEEE.

  1. Development, Field Testing, and Evaluation of LIDAR Assisted Controls

    Energy Technology Data Exchange (ETDEWEB)

    Ehrmann, Robert [Asltom Power Inc.; Wang, Na [National Renewable Energy Lab. (NREL), Golden, CO (United States); Scholbrock, Andrew [National Renewable Energy Lab. (NREL), Golden, CO (United States); Guadayol, Marc [Alstom Power Inc.; Wright, Alan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Arora, Dhiraj [Alstom Power Inc.

    2015-05-18

    Typical wind turbines utilize feedback controllers which have a delayed response to winds peed disturbances. A nacelle mounted LIght Detection and Ranging(LIDAR) system measures a preview wind signal in front of the turbine. This can be included in a feed-forward control system, improving turbine pitch command for incoming variations in wind speed. The overall aim is reduced blade and tower fatigue, and potentially improved annual energy production. To be successful, the LIDAR must yield accurate wind speed measurements. Therefore, a LIDAR was characterized against a nearby met tower and turbine wind speed estimator. Results indicate good correlation between measurements.

  2. Predictive validity of the Biomedical Admissions Test: an evaluation and case study.

    Science.gov (United States)

    McManus, I C; Ferguson, Eamonn; Wakeford, Richard; Powis, David; James, David

    2011-01-01

    There has been an increase in the use of pre-admission selection tests for medicine. Such tests need to show good psychometric properties. Here, we use a paper by Emery and Bell [2009. The predictive validity of the Biomedical Admissions Test for pre-clinical examination performance. Med Educ 43:557-564] as a case study to evaluate and comment on the reporting of psychometric data in the field of medical student selection (and the comments apply to many papers in the field). We highlight pitfalls when reliability data are not presented, how simple zero-order associations can lead to inaccurate conclusions about the predictive validity of a test, and how biases need to be explored and reported. We show with BMAT that it is the knowledge part of the test which does all the predictive work. We show that without evidence of incremental validity it is difficult to assess the value of any selection tests for medicine.

  3. Development and testing of a portfolio evaluation scoring tool.

    Science.gov (United States)

    Karlowicz, Karen A

    2010-02-01

    This study focused on development of a portfolio evaluation tool to guide the assignment of valid and reliable scores. Tool development was facilitated by a literature review, guidance of a faculty committee, and validation by content experts. Testing involved a faculty team that evaluated 60 portfolios. Calculation of interrater reliability and a paired-samples t test were used to judge effectiveness. Interrater reliability was 0.78 for overall scores, 0.81 for the seven program outcomes criteria scores, and more than 0.65 for scores assigned by 11 of 13 pairs of raters. There were no significant differences between raters' scores in 10 of 13 pairs. The portfolio evaluation tool demonstrated high reliability and should be tested by other schools using portfolio evaluation.

  4. Design and evaluation of a computer tutorial on electric fields

    Science.gov (United States)

    Morse, Jeanne Jackson

    Research has shown that students do not fully understand electric fields and their interactions with charged particles after completing traditional classroom instruction. The purpose of this project was to develop a computer tutorial to remediate some of these difficulties. Research on the effectiveness of computer-delivered instructional materials showed that students would learn better from media incorporating user-controlled interactive graphics. Two versions of the tutorial were tested. One version used interactive graphics and the other used static graphics. The two versions of the tutorial were otherwise identical. This project was done in four phases. Phases I and II were used to refine the topics covered in the tutorial and to test the usability of the tutorial. The final version of the tutorial was tested in Phases III and IV. The tutorial was tested using a pretest-posttest design with a control group. Both tests were administered in an interview setting. The tutorial using interactive graphics was more effective at remediating students' difficulties than the tutorial using static graphics for students in Phase III (p = 0.001). In Phase IV students who viewed the tutorial with static graphics did better than those viewing interactive graphics. The sample size in Phase IV was too small for this to be a statistically meaningful result. Some student reasoning errors were noted during the interviews. These include difficulty with the vector representation of electric fields, treating electric charge as if it were mass, using faulty algebraic reasoning to answer questions involving ratios and proportions, and using Coulomb's law in situations in which it is not appropriate.

  5. Principles of Work Sample Testing. 3. Construction and Evaluation of Work Sample Tests

    Science.gov (United States)

    1979-04-01

    validity. Personnel Psychology , 1975, 28, 563-575. Livingston, S. A. A criterion-referenced application of classical test theory. Journal of Educational ...Perfor ance Evaluation, San Antonio, Texas, 23-24 June, 1977. Wesman, A. G. Writing the test item. In R. L. Thorndike (Ed.), Educational measurement...and-pencil tests, was widespread. The Aviation Psychological Program (Guilford, 1947) used a few apparatus tests, such as measures of coor- dination

  6. Isokinetic Testing in Evaluation Rehabilitation Outcome After ACL Reconstruction

    Science.gov (United States)

    Cvjetkovic, Dragana Dragicevic; Bijeljac, Sinisa; Palija, Stanislav; Talic, Goran; Radulovic, Tatjana Nozica; Kosanovic, Milkica Glogovac; Manojlovic, Slavko

    2015-01-01

    Introduction: Numerous rehab protocols have been used in rehabilitation after ACL reconstruction. Isokinetic testing is an objective way to evaluate dynamic stability of the knee joint that estimates the quality of rehabilitation outcome after ACL reconstruction. Our investigation goal was to show importance of isokinetic testing in evaluation thigh muscle strength in patients which underwent ACL reconstruction and rehabilitation protocol. Subjects and methods: In prospective study, we evaluated 40 subjects which were divided into two groups. Experimental group consisted of 20 recreational males which underwent ACL reconstruction with hamstring tendon and rehabilitation protocol 6 months before isokinetic testing. Control group (20 subjects) consisted of healthy recreational males. In all subjects knee muscle testing was performed on a Biodex System 4 Pro isokinetic dynamo-meter et velocities of 60°/s and 180°/s. We followed average peak torque to body weight (PT/BW) and classic H/Q ratio. In statistical analysis Student’s T test was used. Results: There were statistically significant differences between groups in all evaluated parameters except of the mean value of PT/BW of the quadriceps et velocity of 60°/s (p>0.05). Conclusion: Isokinetic testing of dynamic stabilizers of the knee is need in diagnostic and treatment thigh muscle imbalance. We believe that isokinetic testing is an objective parameter for return to sport activities after ACL reconstruction. PMID:25870471

  7. Quick Evaluation of the Annual Heliostat Field Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Collado, F. J.; Monne, C.; Garcia, M.

    2006-07-01

    The recent world wide interest in solar tower power justifies the presentation of a simplified model which allows quick evaluations of the annual energy collected by a surrounding heliostat field. The model is the combination of an analytical model of the flux density produced by a heliostat from Zaragoza University and a optimized mirror density distribution developed by Houston University. The abilities of the combined model are successfully compared against the limited open data about the project Solar Tres. However, the density model should be refined in some aspects and shadowing and blocking should be reviewed in depth using discrete distributions. (Author)

  8. Intervening to decrease the probability of alcohol-impaired driving: Impact of novel field sobriety tests.

    Science.gov (United States)

    Smith, Ryan C; Robinson, Zechariah; Bazdar, Alexandra; Geller, E Scott

    2016-01-01

    The efficacy of novel field sobriety tests to predict breath alcohol content (BAC) and perceptions of driving risk was evaluated. Participants (N = 210) were passersby at two downtown locations near local bars and one on-campus location near a late-night dining facility between the hours of 10:00 p.m. and 2:00 a.m. Participants gave ratings of their perceived risk to drive at their current level of intoxication, then completed three sobriety tests (a hand-pat, tracing test, and Romberg test), and finally provided new ratings of their perceived risk to drive. After completing the final set of questions, participants were administered a Lifeloc FC20 breath alcohol test (±.005 g/dL). Each of the sobriety tests performed better than chance at predicting participant intoxication, but the performance feedback did not enhance awareness of one's risk to drive at a given BAC. Actually, after the sobriety tests, Greek-life females perceived themselves to be less at-risk to drive.

  9. A field assessment of long-term laboratory sediment toxicity tests with the amphipod Hyalella azteca

    Science.gov (United States)

    Ingersoll, Christopher G.; Wang, Ning; Hayward, Jeannie M. R.; Jones, John R.; Jones, Susan B.; Ireland, D. Scott

    2005-01-01

    Response of the amphipod Hyalella azteca exposed to contaminated sediments for 10 to 42 d in laboratory toxicity tests was compared to responses observed in controlled three-month invertebrate colonization exposures conducted in a pond. Sediments evaluated included a sediment spiked with dichlorodiphenyldichloroethane (DDD) or dilutions of a field sediment collected from the Grand Calumet River (GCR) in Indiana (USA) (contaminated with organic compounds and metals). Consistent effects were observed at the highest exposure concentrations (400 ??g DDD/goc [DDD concentrations normalized to grams of organic carbon (goc) in sedimentl or 4% GCR sediment) on survival, length, and reproduction of amphipods in the laboratory and on abundance of invertebrates colonizing sediments in the field. Effect concentrations for DDD observed for 10-d length and 42-d reproduction of amphipods (e.g., chronic value [ChV] of 66 ??g DDD/goc and 25% inhibition concentration [IC25] of 68 ??g DDD/goc for reproduction) were similar to the lowest effect concentrations for DDD measured on invertebrates colonizing sediment the field. Effect concentrations for GCR sediment on 28-d survival and length and 42-d reproduction and length of amphipods (i.e., ChVs of 0.20-0.66% GCR sediment) provided more conservative effect concentrations compared to 10-d survival or length of amphipods in the laboratory or the response of invertebrates colonizing sediment in the field (e.g., ChVs of 2.2% GCR sediment). Results of this study indicate that use of chronic laboratory toxicity tests with H. azteca and benthic colonization studies should be used to provide conservative estimates of impacts on benthic communities exposed to contaminated sediments. Bioaccumulation of DDD by oligochaetes colonizing the DDD-spiked sediment was similar to results of laboratory sediment tests previously conducted with the oligochaete Lumbriculus variegates, confirming that laboratory exposures can be used to estimate

  10. The Evaluation of Flammability Properties Regarding Testing Methods

    Directory of Open Access Journals (Sweden)

    Osvaldová Linda Makovická

    2015-12-01

    Full Text Available In this paper, we address the historical comparison methods with current methods for the assessment of flammability characteristics for materials an especially for wood, wood components and wooden buildings. Nowadays in European Union brings harmonization in evaluated of standards into each European country and try to make one concept of evaluated the flammability properties. In each European country to the one standard level which will be used by evaluation of materials regarding flammability. In our article we focused mainly on improving the evaluation methods in terms of flammability characteristics of using materials at building industry. In the article we present examples of different assessment methods at their own test methods in terms of fire prevention. On the base of old compared of materials by STN, BS and DIN methods for testing materials on fire and new methods of evaluating the flammability properties regarding EU standards before and after starting the flash over.

  11. Workplace field testing of the pressure drop of particulate respirators using welding fumes.

    Science.gov (United States)

    Cho, Hyun-Woo; Yoon, Chung-Sik

    2012-10-01

    In a previous study, we concluded that respirator testing with a sodium chloride aerosol gave a conservative estimate of filter penetration for welding fume aerosols. A rapid increase in the pressure drop (PD) of some respirators was observed as fumes accumulated on the filters. The present study evaluated particulate respirator PD based on workplace field tests. A field PD tester was designed and validated using the TSI 8130 Automatic Filter Tester, designed in compliance with National Institute for Occupational and Safety and Health regulation 42 CFR part 84. Three models (two replaceable dual-type filters and one replaceable single-type filter) were evaluated against CO(2) gas arc welding on mild steel in confined booths in the workplace. Field tests were performed under four airborne concentrations (27.5, 15.4, 7.9, and 2.1 mg m(-3)). The mass concentration was measured by the gravimetric method, and number concentration was monitored using P-Trak (Model 8525, TSI, USA). Additionally, photos and scanning electron microscopy-energy dispersive X-ray spectroscopy were used to visualize and analyze the composition of welding fumes trapped in the filters. The field PD tester showed no significant difference compared with the TSI tester. There was no significant difference in the initial PD between laboratory and field results. The PD increased as a function of fume load on the respirator filters for all tested models. The increasing PD trend differed by models, and PD increased rapidly at high concentrations because greater amount of fumes accumulated on the filters in a given time. The increase in PD as a function of fume load on the filters showed a similar pattern as fume load varied for a particular model, but different patterns were observed for different models. Images and elemental analyses of fumes trapped on the respirator filters showed that most welding fumes were trapped within the first layer, outer web cover, and second layer, in order, while no fumes

  12. Quick evaluation of the annual heliostat field efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Collado, Francisco J. [Univ. Zaragoza, CPS-B, Dpto de Ingenieria Mecanica, Maria de Luna 3, 50018 Zaragoza (Spain)

    2008-04-15

    The recent world wide interest in solar power tower justifies the presentation of a simplified model that allows quick evaluations of the annual overall energy collected by a surrounding heliostat field, which is sent to the electric power generating system (EPGS). The model is the combination of an analytical model of the flux density produced by a heliostat from Zaragoza University, an optimized mirror density distribution developed by University of Houston for the Solar One project and molten salt receiver efficiencies measured during the Solar Two project. The abilities of the model are successfully compared against the scarce open data about the next Solar Tres demonstration plant-a 15 MWe solar tower with molten salts storage. This simplified model could be valid for rather preliminary optimizations, although it should not substitute much more accurate discrete evaluations that manage thousands of individual heliostats with their actual shadowing and blockings, performed every few minutes using actual meteorological data. (author)

  13. Evaluating genomic tests from bench to bedside: a practical framework

    Directory of Open Access Journals (Sweden)

    Lin Jennifer S

    2012-10-01

    Full Text Available Abstract The development of genomic tests is one of the most significant technological advances in medical testing in recent decades. As these tests become increasingly available, so does the need for a pragmatic framework to evaluate the evidence base and evidence gaps in order to facilitate informed decision-making. In this article we describe such a framework that can provide a common language and benchmarks for different stakeholders of genomic testing. Each stakeholder can use this framework to specify their respective thresholds for decision-making, depending on their perspective and particular needs. This framework is applicable across a broad range of test applications and can be helpful in the application and communication of a regulatory science for genomic testing. Our framework builds upon existing work and incorporates principles familiar to researchers involved in medical testing (both diagnostic and prognostic generally, as well as those involved in genomic testing. This framework is organized around six phases in the development of genomic tests beginning with marker identification and ending with population impact, and highlights the important knowledge gaps that need to be filled in establishing the clinical relevance of a test. Our framework focuses on the clinical appropriateness of the four main dimensions of test research questions (population/setting, intervention/index test, comparators/reference test, and outcomes rather than prescribing a hierarchy of study designs that should be used to address each phase.

  14. TESTING GALACTIC MAGNETIC FIELD MODELS USING NEAR-INFRARED POLARIMETRY

    Energy Technology Data Exchange (ETDEWEB)

    Pavel, Michael D.; Clemens, D. P.; Pinnick, A. F., E-mail: pavelmi@bu.edu, E-mail: clemens@bu.edu, E-mail: apinnick@bu.edu [Institute for Astrophysical Research Boston University, 725 Commonwealth Ave, Boston, MA 02215 (United States)

    2012-04-10

    This work combines new observations of NIR starlight linear polarimetry with previously simulated observations in order to constrain dynamo models of the Galactic magnetic field. Polarimetric observations were obtained with the Mimir instrument on the Perkins Telescope in Flagstaff, AZ, along a line of constant Galactic longitude (l = 150 Degree-Sign ) with 17 pointings of the 10' Multiplication-Sign 10' field of view between -75 Degree-Sign < b < 10 Degree-Sign , with more frequent pointings toward the Galactic midplane. A total of 10,962 stars were photometrically measured and 1116 had usable polarizations. The observed distribution of polarization position angles with Galactic latitude and the cumulative distribution function of the measured polarizations are compared to predicted values. While the predictions lack the effects of turbulence and are therefore idealized, this comparison allows significant rejection of A0-type magnetic field models. S0 and disk-even halo-odd magnetic field geometries are also rejected by the observations, but at lower significance. New predictions of spiral-type, axisymmetric magnetic fields, when combined with these new NIR observations, constrain the Galactic magnetic field spiral pitch angle to -6 Degree-Sign {+-} 2 Degree-Sign .

  15. Field testing results for the strategic petroleum reserve pipeline corrosion control program

    Energy Technology Data Exchange (ETDEWEB)

    Buchheit, R.G.; Maestas, L.M.; Hinkebein, T.E.

    1998-02-01

    Results of two studies conducted as part of the Strategic Petroleum Reserve (SPR) Pipeline Corrosion Control Program are reported. These studies focused on evaluation of rotary-applied concrete materials for internal pipeline protection against the erosive and corrosive effects of flowing brine. The study also included evaluation of liners applied by hand on pipe pieces that cannot be lined by rotary methods. Such pipe pieces include tees, elbows and flanged pipe sections. Results are reported from a corrosion survey of 17 different liner formulations tested at the-Big-Rill SPR Site. Testing consisted of electrochemical corrosion rate measurements made on lined pipe sections exposed, in a test manifold, to flowing SPR generated fluids. Testing also involved cumulative immersion exposure where samples were exposed to static site-generated brine for increasing periods of time. Samples were returned to the laboratory for various diagnostic analyses. Results of this study showed that standard calcium silicate concrete (API RP10E) and a rotary calcium aluminate concrete formulation were excellent performers. Hand-lined pipe pieces did not provide as much corrosion protection. The focus of the second part of the study was on further evaluation of the calcium silicate, calcium aluminate and hand-applied liners in actual SPR equipment and service. It was a further objective to assess the practicality of electrochemical impedance spectroscopy (EIS) for field corrosion monitoring of concrete lined pipe compared to the more well-known linear polarization technique. This study showed that concrete linings reduced the corrosion rate for bare steel from 10 to 15 mils per year to 1 mil per year or less. Again, the hand-applied liners did not provide as much corrosion protection as the rotary-applied liners. The EIS technique was found to be robust for field corrosion measurements. Mechanistic and kinetic corrosion rate data were reliably obtained.

  16. Evaluation of Cyantraniliprole and Other Commercial Fly Baits under Laboratory and Field Conditions

    Directory of Open Access Journals (Sweden)

    Casey Parker

    2015-11-01

    Full Text Available Laboratory and field trials were performed to evaluate the attractiveness and efficacy of commercial baits (cyantraniliprole; methomyl + (Z-9-tricosene; dinotefuran + (Z-9-tricosene; imidacloprid granular + (Z-9-tricosene; and imidacloprid liquid + (Z-9-tricosene. In choice tests; flies were most attracted to cyantraniliprole bait > dinotefuran + (Z-9 > methomyl + (Z-9 bait > imidacloprid granular + (Z-9 bait > imidacloprid liquid + (Z-9 bait. Significant degradation in bait efficacy was observed after two weeks of aging excluding imidacloprid granular; which began to degrade in field conditions after one week. Cyantraniliprole; the new fly bait active ingredient in Zyrox®; had the longest time to knockdown in the laboratory tests; but on susceptible flies; achieved 95%–100% knockdown within an hour of exposure. Zyrox® was resistant to weathering for a week; and was more attractive to flies in the field when compared to methomyl + (Z-9 bait.

  17. Evaluation of pesticide toxicity at their field recommended doses to honeybees, Apis cerana and A. mellifera through laboratory, semi-field and field studies.

    Science.gov (United States)

    Stanley, Johnson; Sah, Khushboo; Jain, S K; Bhatt, J C; Sushil, S N

    2015-01-01

    A series of experiments were carried out to determine the acute toxicity of pesticides in the laboratory, toxicity through spray on flowering plants of mustard (Tier II evaluation) and field on both Apis cerana and A. mellifera bees. The overall mortality of honey bees through topical (direct contact) were found significantly higher than that of indirect filter paper contamination assays. Insecticides viz., chlorpyriphos, dichlorvos, malathion, profenofos, monocrotophos and deltamethrin when exposed directly or indirectly at their field recommended doses caused very high mortality up to 100% to both the bees at 48 HAT. The insecticides that caused less mortality through filter paper contamination viz., flubendiamide, methyl demeton, imidacloprid and thiamethoxam caused very high morality through direct exposure. Apart from all the fungicides tested, carbendazim, mancozeb, chlorothalonil and propiconazole, insecticides acetamiprid and endosulfan were found safer to both the bees either by direct or indirect exposures. Tier II evaluation by spray of pesticides at their field recommended doses on potted mustard plants showed monocrotophos as the highly toxic insecticide with 100% mortality even with 1h of exposure followed by thiamethoxam, dichlorvos, profenofos and chlorpyriphos which are not to be recommended for use in pollinator attractive flowering plants. Acetamiprid and endosulfan did not cause any repellent effect on honey bees in the field trials endorse the usage of acetamiprid against sucking pest in flowering plants.

  18. [French version of TASTE (test for the ability and evaluation)].

    Science.gov (United States)

    Masson, A M; Cadot, M; Pereira, A M; Depreeuw, E; Ansseau, M

    2001-01-01

    Ability to study and evaluation is only one example of performance among many others but research and publications concerning this issue for more than 50 years, especially in the context of test anxiety and need of achievement, conferred upon it a prototypical dimension. Investigations about motivation also stimulate many scientists and constitute another foundation of this study (13). The level of performance depends on knowledge and motivation (33). Time devoted to study is essential to succeed; so motivation and procrastination are in competition. The importance of reinforcement (extrinsical motivation) and the desire for learning and knowing (intrinsical motivation) are determinant. Other elements must be emphasized: guarantee of obtaining rewards, self efficacy and causal attribution. These considerations point out the multidimensional and interactive aspects of test anxiety (7, 31). The number of components is not described unanimously but experts agree with emotional, cognitive and behavioral dimensions (25). So, anxiety was approached in its motivational properties, and it was the case until the sixties, in terms of drive corresponding to a need like thirst or hunger (18); then it was conceptualized in a dynamic context broader than that of stress and coping (29, 30). Last, it constitutes the object of theories highlighting cognitive interference (9, 23, 26) or defective skills (8, 32). A lot of questionnaires were built without answering the different aspects and for instance without linking the theoretical and therapeutic components concerning this problem. Committed to the traditional fields of research (test anxiety and need of achievement), to Weiner's work about attribution theory (34) and that of Bandura in self efficacy (4, 5), E. Depreeuw (10) was particularly interested in Heckhausen's model (16, 17), trying to associate experimental conceptions with the clinical reality. On this basis, he elaborated the TASTE (10, 12, 20): test for ability to

  19. 78 FR 29698 - Availability of an Environmental Assessment for Field Testing a Canine Lymphoma Vaccine, DNA

    Science.gov (United States)

    2013-05-21

    ... Service has prepared an environmental assessment concerning authorization to ship for the purpose of field testing, and then to field test, an unlicensed Canine Lymphoma Vaccine, DNA. The environmental assessment... Animal and Plant Health Inspection Service Availability of an Environmental Assessment for Field...

  20. Evaluation of a rapid immunodiagnostic test kit for detection of African lyssaviruses from brain material

    Directory of Open Access Journals (Sweden)

    W. Markotter

    2009-09-01

    Full Text Available Rapid immunodiagnostic test kit was evaluated against a selection of isolates of lyssavirus genotypes occurring in Africa. The test was carried out in parallel comparison with the fluorescent antibody test (FAT and isolates representing previously established phylogenetic groups from each genotype were included. The specificity of the rapid immunodiagnostic test compared favourably with the FAT and was found to detect all representatives of genotypes 1, 2, 3 and 4 in brain samples of either field cases or suckling mouse brain inoculates.

  1. Field Lysimeter Test Facility: Protective barrier test results (FY 1990, the third year)

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, M.D.; Gee, G.W.

    1990-11-01

    The Field Lysimeter Test Facility (FLTF) was constructed to test protective barriers for isolating low-level radioactive and hazardous wastes from the biosphere. Protective barriers are specially configured earth materials placed over near-surface wastes to prevent intrusion of water, plants, and animals. Low-level radioactive waste is stored in near-surface repositories at the Hanford Site and can be transported into the biosphere by water, plants, and animals. The purpose of the FLTF is to measure water balance within barriers as precipitation is partitioned to evaporation (including transpiration), storage, and drainage. Runoff was prevented by raised edges on the lysimeters. Water balance in protective barriers depends on the water-holding capacity of the soil, the gradient of a potential, and the conductivity of the underlying capillary barrier. Current barrier design uses soil with a high water storage capacity and a capillary barrier underlying the soil to increase its water storage capacity. This increased storage capacity is to hold water, which would normally drain, near the the surface where evaporation can cycle it back to the atmosphere. 7 refs., 23 figs., 5 tabs.

  2. Feedback-Based Coverage Directed Test Generation: An Industrial Evaluation

    Science.gov (United States)

    Ioannides, Charalambos; Barrett, Geoff; Eder, Kerstin

    Although there are quite a few approaches to Coverage Directed test Generation aided by Machine Learning which have been applied successfully to small and medium size digital designs, it is not clear how they would scale on more elaborate industrial-level designs. This paper evaluates one of these techniques, called MicroGP, on a fully fledged industrial design. The results indicate relative success evidenced by a good level of code coverage achieved with reasonably compact tests when compared to traditional test generation approaches. However, there is scope for improvement especially with respect to the diversity of the tests evolved.

  3. Statistical Evaluation of Molecular Contamination During Spacecraft Thermal Vacuum Test

    Science.gov (United States)

    Chen, Philip; Hedgeland, Randy; Montoya, Alex; Roman-Velazquez, Juan; Dunn, Jamie; Colony, Joe; Petitto, Joseph

    1999-01-01

    The purpose of this paper is to evaluate the statistical molecular contamination data with a goal to improve spacecraft contamination control. The statistical data was generated in typical thermal vacuum tests at the National Aeronautics and Space Administration, Goddard Space Flight Center (GSFC). The magnitude of material outgassing was measured using a Quartz Crystal Microbalance (QCNO device during the test. A solvent rinse sample was taken at the conclusion of each test. Then detailed qualitative and quantitative measurements were obtained through chemical analyses. All data used in this study encompassed numerous spacecraft tests in recent years.

  4. Automation and Evaluation of the SOWH Test with SOWHAT

    Science.gov (United States)

    Church, Samuel H.; Ryan, Joseph F.; Dunn, Casey W.

    2015-01-01

    The Swofford–Olsen–Waddell–Hillis (SOWH) test evaluates statistical support for incongruent phylogenetic topologies. It is commonly applied to determine if the maximum likelihood tree in a phylogenetic analysis is significantly different than an alternative hypothesis. The SOWH test compares the observed difference in log-likelihood between two topologies to a null distribution of differences in log-likelihood generated by parametric resampling. The test is a well-established phylogenetic method for topology testing, but it is sensitive to model misspecification, it is computationally burdensome to perform, and its implementation requires the investigator to make several decisions that each have the potential to affect the outcome of the test. We analyzed the effects of multiple factors using seven data sets to which the SOWH test was previously applied. These factors include a number of sample replicates, likelihood software, the introduction of gaps to simulated data, the use of distinct models of evolution for data simulation and likelihood inference, and a suggested test correction wherein an unresolved “zero-constrained” tree is used to simulate sequence data. To facilitate these analyses and future applications of the SOWH test, we wrote SOWHAT, a program that automates the SOWH test. We find that inadequate bootstrap sampling can change the outcome of the SOWH test. The results also show that using a zero-constrained tree for data simulation can result in a wider null distribution and higher p-values, but does not change the outcome of the SOWH test for most of the data sets tested here. These results will help others implement and evaluate the SOWH test and allow us to provide recommendations for future applications of the SOWH test. SOWHAT is available for download from https://github.com/josephryan/SOWHAT. PMID:26231182

  5. Field study evaluation of diffuse ceiling ventilation in classroom during real operating conditions

    DEFF Research Database (Denmark)

    Kristensen, Martin Heine; Jensen, Jakob Søland; Heiselberg, Per Kvols

    2017-01-01

    Highlights •Field experimental measurements during real operating conditions. •Evaluation of pressure chamber effect. •Evaluation of displacement effect. •Evaluation of thermal comfort.......Highlights •Field experimental measurements during real operating conditions. •Evaluation of pressure chamber effect. •Evaluation of displacement effect. •Evaluation of thermal comfort....

  6. Self-contained self-rescuer long term field evaluation: combined eighth and ninth phase results

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-10-15

    The National Institute for Occupational Safety and Health (NIOSH) National Personal Protective Technology Laboratory (NPPTL) and the Mine Safety and Health Administration (MSHA) conduct a Long Term Field Evaluation (LTFE) program to evaluate deployed self-contained self rescuers (SCSRs). The objective of the program is to evaluate how well SCSRs endure the underground coal mining environment with regard to both physical damage and aging when they are deployed in accordance with Federal regulations (30 CFR 75.1714). This report presents findings of the combined eighth and ninth phases of the LTFE. For these phases, over four hundred SCSRs were evaluated. The units tested include the CSE SR-100, Draeger Oxy K-Plus, MSA Life-saver 60, and the OCENCO EBA 6.5. The OCENCO 20 was evaluated only in Phase 9. Testing was performed between December 2000 and April 2004. Results of the evaluation indicate that all SCSRs experience some performance degradation due to the mining environment. Observed degradation varies from elevated levels of carbon dioxide, high breathing resistance, and reduced capacity. Mechanical degradation to the SCSR components included breathing hoses, chemical beds, outer cases and seals. The LTFE tests discussed in this report are different from tests performed for SCSR certification to the requirements of 42 Code of Federal Regulations, Part 84 (42 CFR, Part 84). LTFE tests reported here are conducted to an end point, oxygen depletion, to enable comparison of the duration of new and deployed SCSRs. The method for obtaining deployed SCSRs for this evaluation was not a random selection from the deployed population of SCSRs. Although the results of these tests are useful for observing performance of the tested SCSRs, they are not representative of all deployed SCSRs. 9 refs., 10 figs., 9 tabs., 3 apps.

  7. Preliminary field evaluation of high efficiency steel filters

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, W.; Larsen, G.; Lopez, R. [Lawrence Livermore National Laboratory, CA (United States)] [and others

    1995-02-01

    We have conducted an evaluation of two high efficiency steel filters in the exhaust of an uranium oxide grit blaster at the Y-12 Plant in Oak Ridge Tennessee. The filters were installed in a specially designed filter housing with a reverse air-pulse cleaning system for automatically cleaning the filters in-place. Previous tests conducted on the same filters and housing at LLNL under controlled conditions using Arizona road dust showed good cleanability with reverse air pulses. Two high efficiency steel filters, containing 64 pleated cartridge elements housed in the standard 2` x 2` x 1` HEPA frame, were evaluated in the filter test housing using a 1,000 cfm slip stream containing a high concentration of depleted uranium oxide dust. One filter had the pleated cartridges manufactured to our specifications by the Pall Corporation and the other by Memtec Corporation. Test results showed both filters had a rapid increase in pressure drop with time, and reverse air pulses could not decrease the pressure drop. We suspected moisture accumulation in the filters was the problem since there were heavy rains during the evaluations, and the pressure drop of the Memtec filter decreased dramatically after passing clean, dry air through the filter and after the filter sat idle for one week. Subsequent laboratory tests on a single filter cartridge confirmed that water accumulation in the filter was responsible for the increase in filter pressure drop and the inability to lower the pressure drop by reverse air pulses. No effort was made to identify the source of the water accumulation and correct the problem because the available funds were exhausted.

  8. Evaluation of free-field transfer functions in anomalous reverberant fields

    Science.gov (United States)

    Cheng, Guo; He, Lin; Xu, Rongwu

    2017-01-01

    The structural-acoustic transfer functions of complex structures are often measured in anomalous reverberant environments. Aiming to eliminating the influences of these reverberant fields on structural-acoustic transfer functions, an impulse-based synchronization average evaluation method is proposed. Structures are actuated according to an impulse signal, and the response signals are synchronized in time and averaged in space. This method does not require complex data processing, and the free-field transfer functions can be obtained based on the measurements in reverberant fields and the transfer characteristics of the structures are preserved. Moreover, in combination with the principle of reciprocity, the proposed method does not require the installation of impulse actuators in structures. The proposed method is verified numerically and validated in a deep lake experiment using a cylindrical model. The results show that the structural-acoustic transfer functions in the profundal zone can be effectively evaluated using the data collected in the shallow zone, and the error is less than 3 dB at most frequencies.

  9. Evaluation of landmine detection performance applying two different algorithms to GPR field data

    Science.gov (United States)

    Mendez-Rial, Roi; Uschkerat, U.; Rial, F. I.; Gonzalez-Huici, Maria A.

    2013-06-01

    This paper evaluates and compares the performance of two algorithms that have previously demonstrated their potential in underground target detection. Field data was obtained on specially prepared test fields, where various mine simulants, reference objects, and mine-like clutter where placed at precise locations in different soil types. The efficiency of both algorithms in terms of detection accuracies (ROC curves) and computational burden is compared, as well as the impact of preprocessing strategies. Based on the results, we discuss the convenience of both methods to be integrated in a real - time signal processing system considering their benefits and drawbacks.

  10. Evaluation of Aqua-Ammonia Chiller Technologies and Field Site Installation

    Energy Technology Data Exchange (ETDEWEB)

    Zaltash, Abdolreza [ORNL

    2007-09-01

    The Naval Facilities Engineering Service Center (NFESC) has sponsored Oak Ridge National Laboratory (ORNL) to review, select, and evaluate advanced, gas-fired, 5-ton, aqua-ammonia, chiller technologies. The selection criteria was that units have COP values of 0.67 or better at Air-conditioning and Refrigeration Institute (ARI) 95 F outdoor rating conditions, an active refrigerant flow control, and a variable-speed condenser fan. These features are expected to allow these units to operate at higher ambient temperatures (up to the maximum operating temperature of 110 F) with minimal degradation in performance. ORNL evaluated three potential manufacturers of advanced, gas-fired, 5-ton, aqua-ammonia chillers-Robur, Ambian, and Cooling Technologies. Unfortunately, Robur did not meet the COP requirements and Cooling Technologies could not deliver a unit to be tested at the U.S. Department of Energy (DOE)-ORNL environmental chamber testing facility for thermally activated heat pumps. This eliminated these two technologies from further consideration, leaving only the Ambian chillers for evaluation. Two Ambian chillers were evaluated at the DOE-ORNL test facility. Overall these chillers operated well over a wide range of ambient conditions with minimal degradation in performance due to several control strategies used such as a variable speed condenser fan, a modulating burner, and active refrigerant flow control. These Ambian pre-commercial units were selected for installation and field testing at three federal facilities. NFESC worked with ORNL to assist with the site selection for installation and evaluation of these chillers. Two sites (ORNL and Naval Surface Warfare Center [NSWC] Corona) had a single chiller unit installed; and at one site (Naval Amphibious Base [NAB] Little Creek), two 5-ton chillers linked together were installed to provide 10 tons of cooling. A chiller link controller developed under this project was evaluated in the field test at Little Creek.

  11. Testing Chameleon Theories with Light Propagating through a Magnetic Field

    CERN Document Server

    Brax, P; Davis, A C; Mota, D F; Shaw, D J

    2007-01-01

    It was recently argued that the observed PVLAS anomaly can be explained by chameleon field theories in which large deviations from Newton's law can be avoided. Here we present the predictions for the dichroism and the birefringence induced in the vacuum by a magnetic field in these models. We show that chameleon particles behave very differently from standard axion-like particles (ALPs). We find that, unlike ALPs, the chameleon particles are confined within the experimental set-up. As a consequence, the birefringence is always bigger than the dichroism in PVLAS-type experiments.

  12. A semi-field approach to testing effects of fresh pesticide residues on bees in multiple-rate test

    NARCIS (Netherlands)

    Bakker, F.; Calis, J.N.M.

    2003-01-01

    We describe a semi-field cage test specifically designed to test effects of delayed exposure to plant protection products. The trial involved the use of standardised mini-beehives. The principle of the trial was to prepare two groups of potted test plants per treatment. The first group of plants rem

  13. Vigor tests to evaluate the physiological quality of corn seeds cv. 'Sertanejo'

    Directory of Open Access Journals (Sweden)

    Daniela Vieira dos Anjos Sena

    Full Text Available ABSTRACT: The vigor tests are intended to monitor the quality of seeds as it allows reliably distinguish lots of low and high vigor, providing additional information to the germination test. So in this study the objective was to identify the most efficient vigor tests on stratification of lots of corn seeds cv. 'Sertanejo'. The experiment was conducted at Laboratory of Seed Analysis at the Center of agricultural Science of the Universidade Federal da Paraíba, using samples from 20 seed lots in a completely randomized design. For characterization of the lots it was evaluated water content, germination and vigor (cold test, electrical conductivity, accelerated aging, seedling emergence in field and germination at low temperatures. The accelerated aging, electrical conductivity and field emergence of seedlings tests are the most efficient for classification of lots of corn seeds cv. 'Sertanejo' in levels of vigor, been the seeds of lot 1 the most vigorous.

  14. Field Test of the World Health Organization Multi-Professional Patient Safety Curriculum Guide

    Science.gov (United States)

    Farley, Donna; Zheng, Hao; Rousi, Eirini; Leotsakos, Agnès

    2015-01-01

    Introduction Although the importance of training in patient safety has been acknowledged for over a decade, it remains under-utilized and under-valued in most countries. WHO developed the Multi-professional Patient Safety Curriculum Guide to provide schools with the requirements and tools for incorporating patient safety in education. It was field tested with 12 participating schools across the six WHO regions, to assess its effectiveness for teaching patient safety to undergraduate and graduate students in a global variety of settings. Methods The evaluation used a combined prospective/retrospective design to generate formative information on the experiences of working with the Guide and summative information on the impacts of the Guide. Using stakeholder interviews and student surveys, data were gathered from each participating school at three times: the start of the field test (baseline), soon after each school started teaching, and soon after each school finished teaching. Results Stakeholders interviewed were strongly positive about the Guide, noting that it emphasized universally important patient safety topics, was culturally appropriate for their countries, and gave credibility and created a focus on patient safety at their schools. Student perceptions and attitudes regarding patient safety improved substantially during the field test, and their knowledge of the topics they were taught doubled, from 10.7% to 20.8% of correct answers on the student survey. Discussion This evaluation documented the effectiveness of the Curriculum Guide, for both ease of use by schools and its impacts on improving the patient safety knowledge of healthcare students. WHO should be well positioned to refine the contents of the Guide and move forward in encouraging broader use of the Guide globally for teaching patient safety. PMID:26406893

  15. Field Test of the World Health Organization Multi-Professional Patient Safety Curriculum Guide.

    Science.gov (United States)

    Farley, Donna; Zheng, Hao; Rousi, Eirini; Leotsakos, Agnès

    2015-01-01

    Although the importance of training in patient safety has been acknowledged for over a decade, it remains under-utilized and under-valued in most countries. WHO developed the Multi-professional Patient Safety Curriculum Guide to provide schools with the requirements and tools for incorporating patient safety in education. It was field tested with 12 participating schools across the six WHO regions, to assess its effectiveness for teaching patient safety to undergraduate and graduate students in a global variety of settings. The evaluation used a combined prospective/retrospective design to generate formative information on the experiences of working with the Guide and summative information on the impacts of the Guide. Using stakeholder interviews and student surveys, data were gathered from each participating school at three times: the start of the field test (baseline), soon after each school started teaching, and soon after each school finished teaching. Stakeholders interviewed were strongly positive about the Guide, noting that it emphasized universally important patient safety topics, was culturally appropriate for their countries, and gave credibility and created a focus on patient safety at their schools. Student perceptions and attitudes regarding patient safety improved substantially during the field test, and their knowledge of the topics they were taught doubled, from 10.7% to 20.8% of correct answers on the student survey. This evaluation documented the effectiveness of the Curriculum Guide, for both ease of use by schools and its impacts on improving the patient safety knowledge of healthcare students. WHO should be well positioned to refine the contents of the Guide and move forward in encouraging broader use of the Guide globally for teaching patient safety.

  16. Evaluation of Alternative Field Buses for Lighting ControlApplications

    Energy Technology Data Exchange (ETDEWEB)

    Koch, Ed; Rubinstein, Francis

    2005-03-21

    The Subcontract Statement of Work consists of two major tasks. This report is the Final Report in fulfillment of the contract deliverable for Task 1. The purpose of Task 1 was to evaluate existing and emerging protocols and standards for interfacing sensors and controllers for communicating with integrated lighting control systems in commercial buildings. The detailed task description follows: Task 1. Evaluate alternative sensor/field buses. The objective of this task is to evaluate existing and emerging standards for interfacing sensors and controllers for communicating with integrated lighting control systems in commercial buildings. The protocols to be evaluated will include at least: (1) 1-Wire Net, (2) DALI, (3) MODBUS (or appropriate substitute such as EIB) and (4) ZigBee. The evaluation will include a comparative matrix for comparing the technical performance features of the different alternative systems. The performance features to be considered include: (1) directionality and network speed, (2) error control, (3) latency times, (4) allowable cable voltage drop, (5) topology, and (6) polarization. Specifically, Subcontractor will: (1) Analyze the proposed network architecture and identify potential problems that may require further research and specification. (2) Help identify and specify additional software and hardware components that may be required for the communications network to operate properly. (3) Identify areas of the architecture that can benefit from existing standards and technology and enumerate those standards and technologies. (4) Identify existing companies that may have relevant technology that can be applied to this research. (5) Help determine if new standards or technologies need to be developed.

  17. The application of strength and power related field tests in older adults : criteria, current status and a future perspective

    NARCIS (Netherlands)

    Regterschot, G. Ruben H.; Morat, Tobias; Folkersma, Marjanne; Zijlstra, Wiebren

    2015-01-01

    Leg muscle strength (LMS) and leg muscle power (LMP) are determinants of aspects of functional status and important parameters for measuring intervention effects in older adults. Field tests are often used for the evaluation of LMS and LMP in older persons. However, criteria important for the applic

  18. The application of strength and power related field tests in older adults : criteria, current status and a future perspective

    NARCIS (Netherlands)

    Regterschot, G. Ruben H.; Morat, Tobias; Folkersma, Marjanne; Zijlstra, Wiebren

    2015-01-01

    Leg muscle strength (LMS) and leg muscle power (LMP) are determinants of aspects of functional status and important parameters for measuring intervention effects in older adults. Field tests are often used for the evaluation of LMS and LMP in older persons. However, criteria important for the applic

  19. Laboratory and Field Tests of Ultrasonic Sensors for Precision Sprayers

    Science.gov (United States)

    Reliable function of sensors under rough field conditions is required for the development of variable-rate sprayers to deliver pest control agents to tree liners in ornamental nurseries. Two ultrasonic sensors were examined to identify how their durability and detection stability would be influenced...

  20. Translating laboratory compaction test results to field scale

    NARCIS (Netherlands)

    Roholl, J.A.; Thienen-Visser, K. van; Breunese, J.N.

    2016-01-01

    In recent studies on the surface subsidence caused by hydrocarbon recovery of the Groningen gas field, the predicted subsidence is overestimated if results of compaction experiments are not corrected by an empirical `upscaling factor'. In order to find an explanation for this `upscaling factor', an

  1. Test of Scintillometer Saturation Correction Methods Using Field Experimental Data

    NARCIS (Netherlands)

    Kleissl, J.; Hartogensis, O.K.; Gomez, J.D.

    2010-01-01

    Saturation of large aperture scintillometer (LAS) signals can result in sensible heat flux measurements that are biased low. A field study with LASs of different aperture sizes and path lengths was performed to investigate the onset of, and corrections for, signal saturation. Saturation already occu

  2. Developing a Test Collection for the Evaluation of Integrated Search

    DEFF Research Database (Denmark)

    Lykke, Marianne; Larsen, Birger; Lund, Haakon;

    2010-01-01

    he poster discusses the characteristics needed in an information retrieval (IR) test collection to facilitate the evaluation of integrated search, i.e. search across a range of different sources but with one search box and one ranked result list, and describes and analyses a new test collection...... constructed for this purpose. The test collection consists of approx. 18,000 monographic records, 160,000 papers and journal articles in PDF and 275,000 abstracts with a varied set of metadata and vocabularies from the physics domain, 65 topics based on real work tasks and corresponding graded relevance...... assessments. The test collection may be used for systems- as well as user-oriented evaluation....

  3. Test Method for Compression Resilience Evaluation of Textiles

    Directory of Open Access Journals (Sweden)

    Shui-yuan Hong

    2013-02-01

    Full Text Available A test method was proposed and a measurement system was developed to characterize the compression resilience properties of textiles based on the mechanical device, microelectronics, sensors and control system. Derived from the typical pressure-displacement curve and test data, four indices were defined to characterize the compression performance of textiles. The test principle and the evaluation method for compression resilience of textiles were introduced. Twelve types of textile fabrics with different structural features and made from different textile materials were tested. The one-way ANOVA analysis was carried out to identify the significance of the differences of the evaluation indices among the fabrics. The results show that each index is significantly different among different fabrics. The denim has the maximum compressional resilience and the polar fleece has the minimum compressional resilience.

  4. Consensus on Intermediate Scale Salt Field Test Design

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlman, Kristopher L; Mills, Melissa Marie; Matteo, Edward N

    2017-03-01

    This report summarizes the first stage in a collaborative effort by Sandia, Los Alamos, and Lawrence Berkeley National Laboratories to design a small-diameter borehole heater test in salt at the Waste Isolation Pilot Plant (WIPP) for the US Department of Energy Office of Nuclear Energy (DOE-NE). The intention is to complete test design during the remainder of fiscal year 2017 (FY17), and the implementation of the test will begin in FY18. This document is the result of regular meetings between the three national labs and the DOE-NE, and is intended to represent a consensus of these meetings and discussions.

  5. Stress Optical Coefficient, Test Methodology, and Glass Standard Evaluation

    Science.gov (United States)

    2016-05-01

    it can be used as an additional glass characterization method . If the SOC of a glass sample is known, the stress state of a glass specimen can be...evaluated through photoelastic methods both qualitatively and quantitatively. Approved for public release; distribution is unlimited. 11 8...ARL-TN-0756 ● MAY 2016 US Army Research Laboratory Stress Optical Coefficient, Test Methodology, and Glass Standard Evaluation

  6. Field test results of the physical solvent N-Formyl morpholine for gas treating applications

    Energy Technology Data Exchange (ETDEWEB)

    Palla, N.; Lee, A.L.

    1997-12-31

    The Institute of Gas Technology (IGT) is developing gas processing technology that will reduce gas processing costs for current production and allow subquality gas to be economically produced that would have been otherwise, not produced. The experimental program has primarily focused on the evaluation of N-Formyl Morpholine (NFM) as a physical solvent for the cost-effective upgrading of subquality natural gas to pipeline quality. The selection of NFM for this program was based on previous work conducted by IGT in the selective removal of hydrogen sulfide, and carbon dioxide from coal gasifier effluents. That work showed that the use of NFM resulted in a significant cost advantage over 107 other solvents for that application. The project approach for the development of NFM process has been divided into following main categories: obtain vapor-liquid equilibrium, physical properties and additional published literature data; obtain mass-transfer coefficients using 2 inch absorber/stripper apparatus and calculate equation of state parameters and binary interaction parameters using VLE data; develop a gas processing model using Aspen Plus simulation program and evaluate economic advantages of the NFM process compared to commercial physical solvent; and design a pilot plant skid mounted field test unit and conduct field test experiments.

  7. Review: J-integral resistance curve testing and evaluation

    Institute of Scientific and Technical Information of China (English)

    Xian-kui ZHU

    2009-01-01

    In this paper a critical review is presented of the history and current state of the art of J-integral resistance curve testing and experimental evaluation methods in conjunction with a discussion of the development of the plane strain fracture toughness test standard ASTM E 1820 developed by American Society for Testing and Materials (ASTM). Early research efforts on this topic are reviewed first. These include the J-integral concept, experimental estimates of the J-integral for stationary cracks, load line displacement (LLD) and crack mouth opening displacement (CMOD) based η factor equations, different formulations of J-integral incremental equations for growing cracks, crack growth corrected J-R curve determination, and experimental test methods. Recent developments in J-R curve testing and evaluation are then described, with emphasis on accurate J-integral incremental equations,a normalization method, a modified basic method, a CMOD direct method with use of incremental equations, relationships of plastic geometry factors, constraint-dependent J-R curve testing and correction approaches. An overview of the present fracture toughness test standard ASTM E1820-08a is then presented. The review shows that after more than 40 years of investigation and development, the J-integral resistance curve test methods in ASTM E 1820 have become simpler, more cost-effective and more accurate.

  8. General test plan redundant sensor strapdown IMU evaluation program

    Science.gov (United States)

    Hartwell, T.; Irwin, H. A.; Miyatake, Y.; Wedekind, D. E.

    1971-01-01

    The general test plan for a redundant sensor strapdown inertial measuring unit evaluation program is presented. The inertial unit contains six gyros and three orthogonal accelerometers. The software incorporates failure detection and correction logic and a land vehicle navigation program. The principal objective of the test is a demonstration of the practicability, reliability, and performance of the inertial measuring unit with failure detection and correction in operational environments.

  9. Director, Operational Test and Evaluation FY 2014 Annual Report

    Science.gov (United States)

    2015-01-01

    training continues at Eglin AFB, Florida , and expanded in September 2014 when additional F-35B training began at MCAS Beaufort, South Carolina...sensor from a shore base at the contractor’s facility in West Palm Beach, Florida . A third phase of testing described by the RMS Test and Evaluation...Martin – West Palm Beach, Florida • AN/AQS-20A: Raytheon Corporation – Portsmouth, Rhode Island the LCS MCM mission package and therefore would not

  10. Wartime Test and Evaluation; Initiatives Lead to Cultural Change

    Science.gov (United States)

    2007-05-14

    Realignment and Closure (BRAC) decision; Yuma Proving Ground (YPG), Arizona; and White Sands Missile Range (WSMR), New Mexico , and each specializes in...MRTFBs, led to the “ Uber Lean” process of evaluating each test center’s mission, functions and core competencies. That analysis identified each test...facilities that could be eliminated. The outcome led to the development of investment strategies from a holistic DTC perspective. The DTC “ Uber Lean

  11. Field and laboratory tests on acute toxicity of cadmium to freshwater crayfish

    Energy Technology Data Exchange (ETDEWEB)

    1986-09-01

    Environmental regulatory standards for cadmium (EPA 1980), like those for most pollutants, are based on acute, laboratory toxicity tests of single species. Such tests can be conducted rapidly and inexpensively in comparison to acute or chronic field studies, but their validity has often been questioned. Laboratory-based criteria are subject to two criticisms: (1) chemical and physical conditions differ greatly in degree and variability from laboratory to field, and (2) species are not isolated, but live in an ecosystem of interacting taxa and biofeedback. To investigate the validity of basing field toxicity standards on laboratory data, the authors subjected the freshwater crayfish Orconectes immunis for 96 h to various levels of cadmium in laboratory aquaria and experimental ponds. The study was designed to evaluate in part the first criticism of lab-based criteria. The studies were conducted concurrently with similar short-term experiments on the fathead minnow, Pimephales promelas, and coincided with studies of chronic cadmium stress on fathead minnows in experimental ponds.

  12. Field Testing of High Current Electrokinetic Nanoparticle Treatment for Corrosion Mitigation in Reinforced Concrete

    Science.gov (United States)

    Cardenas, Henry; Alexander, Joshua; Kupwade-Patil, Kunal; Calle, Luz marina

    2010-01-01

    Electrokinetic Nanoparticle (EN) treatment was used as a rapid repair measure to mitigate chloride induced corrosion of reinforced concrete in the field. EN treatment uses an electric field to transport positively charged nanoparticles to the reinforcement through the concrete capillary pores. Cylindrical reinforced concrete specimens were batched with 4.5 wt % salt content (based on cement mass). Three distinct electrokinetic treatments were conducted using high current density (up to 5 A/m2) to form a chloride penetration barrier that was established in 5 days, as opposed to the traditional 6-8 weeks, generally required for electrochemical chloride extraction (ECE). These treatments included basic EN treatment, EN with additional calcium treatment, and basic ECE treatment. Field exposures were conducted at the NASA Beachside Corrosion Test Site, Kennedy Space Center, Florida, USA. The specimens were subjected to sea water immersion at the test site as a posttreatment exposure. Following a 30-day post-treatment exposure period, the specimens were subjected to indirect tensile testing to evaluate treatment impact. The EN treated specimens exhibited 60% and 30% increases in tensile strength as compared to the untreated controls and ECE treated specimens respectively. The surfaces of the reinforcement bars of the control specimens were 67% covered by corrosion products. In contrast, the EN treated specimens exhibited corrosion coverage of only 4%. Scanning electron microscopy (SEM) revealed a dense concrete microstructure adjacent to the bars of the treated specimens as compared to the control and ECE specimens. Energy dispersive spectroscopic (EDS) analysis of the polished EN treated specimens showed a reduction in chloride content by a factor of 20 adjacent to the bars. This study demonstrated that EN treatment was successful in forming a chloride penetration barrier rapidly. This work also showed that the chloride barrier was effective when samples were exposed to

  13. SMART Wind Turbine Rotor: Design and Field Test

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Jonathan C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Resor, Brian R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Paquette, Joshua A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); White, Jonathan R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-01-29

    This report documents the design, fabrication, and testing of the SMART Rotor. This work established hypothetical approaches for integrating active aerodynamic devices (AADs) into the wind turbine structure and controllers.

  14. Three dimensional hemispherical test development to evaluate detonation wave breakout

    Science.gov (United States)

    Francois, E. G.; Morris, J. S.; Lieber, M.

    2014-05-01

    The Onionskin test has been the standard test to evaluate detonation wave breakout over a hemispherical surface for decades. It has been an effective test used in a variety of applications to qualify main charge materials, evaluate different boosters, and compare different detonators. It is not without its shortfalls however. It only images a small portion of the explosive and requires very precise alignment and camera requirements to make sense of the results. Asymmetry in explosive behavior cannot be pinpointed or evaluated effectively. We have developed a new diagnostic using fiber optics covering the surface of the explosive to yield a 3D representation of the detonation wave behavior. Precise timing mapping of the detonation over the hemispherical surface is generated which can be converted to detonation wave breakout behavior using Huygens' wave reconstruction. This report will include the results of a recent suite of tests on PBX 9501, and discussion of how the test was developed for this explosive and contrasting previous work on PBX 9502. The results of these tests will describe the effects on detonation wave breakout symmetry when Sylgard 184 is placed between the detonator and booster. The effects on symmetry and timing when the Sylgard gap thickness is increased and the detonator is canted will be shown.

  15. Initial field testing definition of subsurface sealing and backfilling tests in unsaturated tuff; Yucca Mountain Site Characterization Project

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, J.A. [Sandia National Labs., Albuquerque, NM (United States); Case, J.B.; Tyburski, J.R. [I. T. Corp., Albuquerque, NM (United States)

    1993-05-01

    This report contains an initial definition of the field tests proposed for the Yucca Mountain Project repository sealing program. The tests are intended to resolve various performance and emplacement concerns. Examples of concerns to be addressed include achieving selected hydrologic and structural requirements for seals, removing portions of the shaft liner, excavating keyways, emplacing cementitious and earthen seals, reducing the impact of fines on the hydraulic conductivity of fractures, efficient grouting of fracture zones, sealing of exploratory boreholes, and controlling the flow of water by using engineered designs. Ten discrete tests are proposed to address these and other concerns. These tests are divided into two groups: Seal component tests and performance confirmation tests. The seal component tests are thorough small-scale in situ tests, the intermediate-scale borehole seal tests, the fracture grouting tests, the surface backfill tests, and the grouted rock mass tests. The seal system tests are the seepage control tests, the backfill tests, the bulkhead test in the Calico Hills unit, the large-scale shaft seal and shaft fill tests, and the remote borehole sealing tests. The tests are proposed to be performed in six discrete areas, including welded and non-welded environments, primarily located outside the potential repository area. The final selection of sealing tests will depend on the nature of the geologic and hydrologic conditions encountered during the development of the Exploratory Studies Facility and detailed numerical analyses. Tests are likely to be performed both before and after License Application.

  16. Field Jet Erosion Tests on the Mississippi River Collocated Demonstration Section, Plaquemines Parish, Louisiana

    Science.gov (United States)

    2015-06-01

    ER D C/ G SL T R- 15 -1 3 Field Jet Erosion Tests on the Mississippi River Collocated Demonstration Section, Plaquemines Parish...default. ERDC/GSL TR-15-13 June 2015 Field Jet Erosion Tests on the Mississippi River Collocated Demonstration Section, Plaquemines Parish...Prepared for U.S. Army Corps of Engineers Washington, DC 20314-1000 ERDC/GSL TR-15-13 ii Abstract Field jet erosion tests (JETs) were

  17. Controllability analysis and testing of a novel magnetorheological absorber for field gun recoil mitigation

    Science.gov (United States)

    Ouyang, Qing; Zheng, Jiajia; Li, Zhaochun; Hu, Ming; Wang, Jiong

    2016-11-01

    This paper aims to analyze the effects of combined working coils of magnetorheological (MR) absorber on the shock mitigation performance and verify the controllability of MR absorber as applied in the recoil system of a field gun. A physical scale model of the field gun is established and a long-stroke MR recoil absorber with four-stage parallel electromagnetic coils is designed to apply separate current to each stage and generate variable magnetic field distribution in the annular flow channel. Based on dynamic analysis and firing stability conditions of the field gun, ideal recoil force-stroke profiles of MR absorber at different limiting firing angles are obtained. The experimental studies are carried out on an impact test rig under different combinations of current loading: conventional unified control mode, separate control mode and timing control mode. The fullness degree index (FDI) is defined as the quantitative evaluation criterion of the controllability of MR absorber during the whole recoil motion. The results show that the force-stroke profile of the novel MR absorber can approach the ideal curve within 25 degrees of the limiting firing angle through judicious exploitation of the adjustable rheological properties of MR fluid.

  18. [Evaluation of latex agglutination test for anti-treponemal antibody in comparison with chemical luminescence tests].

    Science.gov (United States)

    Watanabe, Naomi; Nagatomo, Ritsuko; Okubo, Shigeo; Yokota, Hiromitsu; Ikeda, Hitoshi; Yatomi, Yutaka

    2011-02-01

    The performance of a latex agglutination test (Mediace TPLA) in the detection of anti-treponemal antibody was evaluated in comparison with chemical luminescence tests (LumipulsII-N and Architect TPAb) in 346 cases. Anti-treponemal antibody was further determined by immunochromatography and immunoblotting tests and additionally evaluated by a serological test for syphilis with lipoidal antigens. The total concordance rate between the latex agglutination test and chemical luminescence tests ranged from 96% to 97%: the positive concordance rate ranged from 96% to 97%, and the negative concordance rate, from 97% to 98%. The latex agglutination test showed two false positive cases, and each chemical luminescence test showed two false positive cases, respectively. In eight cases, only the latex agglutination test showed negative results; all specimens contained anti-treponemal antibodies. However, none of these was considered to be a false positive and each was treated as syphilis based on the results of confirmatory analysis with immunochromatography and immunoblotting tests and a serological test for syphilis. The discordant results in the latex agglutination test and chemical luminescence tests may be caused by the different antigenisity of each test. With detailed analysis of those sera treated as syphilis, each specimen was found to contain various antibodies against syphilitic antigens, suggesting that there was a different specificity of native and recombinant antigens. Based on the present results for the comparison between the latex agglutination test and chemical luminescence tests, it was considered that further investigation is necessary to clarify the anti-treponemal antibody profile of syphilis at the disease stage.

  19. Tests and Field Map of LHCb Dipole Magnet

    CERN Document Server

    Losasso, Marcello; Flegel, Wilfried; Giudici, Pierre-Ange; Hernando, Jose Angel; Jamet, Olivier; Lindner, Rolf; Renaud, Jean; Teubert, Frederic

    2005-01-01

    The LHCb experiment at the LHC at CERN is aimed to study CP violation and to measure the rare decays of B-mesons with exceptionally high precision. A 4 Tm dipole magnet is required for particle separation and momentum measurements. The 1600 ton warm magnet with sloping poles was installed and fully commissioned by the end of 2004. It is the first detector magnet of the four LHC experiments to have been aligned and commissioned in its final position. In this paper the magnet installation in the underground cavern of Point 8 and its alignment on the beam line are shortly reviewed. Results of a first magnetic field mapping in the region of the magnet poles and the fringe field in the location of the RICH detectors are presented. The mechanical equipment used for the automatic displacement of the Hall probe array is described together with the precision of the measurements obtained which are compared with TOSCA finite element calculations.

  20. Sound field control for a low-frequency test facility

    DEFF Research Database (Denmark)

    Pedersen, Christian Sejer; Møller, Henrik

    2013-01-01

    The two largest problems in controlling the reproduction of low-frequency sound for psychoacoustic experiments is the effect of the room due to standing waves and the relatively large sound pressure levels needed. Anechoic rooms are limited downward in frequency and distortion may be a problem even...... at moderate levels, while pressure-field playback can give higher sound pressures but is limited upwards in frequency. A new solution that addresses both problems has been implemented in the laboratory of Acoustics, Aalborg University. The solution uses one wall with 20 loudspeakers to generate a plane wave...... that is actively absorbed when it reaches the 20 loudspeakers on the opposing wall. This gives a homogeneous sound field in the majority of the room with a flat frequency response in the frequency range 2-300 Hz. The lowest frequencies are limited to sound pressure levels in the order of 95 dB. If larger levels...