WorldWideScience

Sample records for field injection test

  1. Finalize field testing of cold climate heat pump (CCHP) based on tandem vapor injection compressors

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-03-01

    This report describes the system diagram and control algorithm of a prototype air-source cold climate heat pump (CCHP) using tandem vapor injection (VI) compressors. The prototype was installed in Fairbanks, Alaska and underwent field testing starting in 09/2016. The field testing results of the past six months, including compressor run time fractions, measured COPs and heating capacities, etc., are presented as a function of the ambient temperature. Two lessons learned are also reported.

  2. In Situ Redox Manipulation Field Injection Test Report - Hanford 100-H Area

    Energy Technology Data Exchange (ETDEWEB)

    Fruchter, J.S.; Amonette, J.E.; Cole, C.R. [and others

    1996-11-01

    This report presents results of an In Situ Redox Manipulation (ISRM) Field Injection Withdrawal Test performed at the 100-H Area of the US. Department of Energy`s (DOE`s) Hanford Site in Washington State in Fiscal Year 1996 by researchers at Pacific Northwest National Laboratory (PNNL). The test is part of the overall ISRM project, the purpose of which is to determine the potential for remediating contaminated groundwater with a technology based on in situ manipulation of subsurface reduction-oxidation (redox) conditions. The ISRM technology would be used to treat subsurface contaminants in groundwater zones at DOE sites.

  3. Field Testing of Activated Carbon Injection Options for Mercury Control at TXU's Big Brown Station

    Energy Technology Data Exchange (ETDEWEB)

    John Pavlish; Jeffrey Thompson; Christopher Martin; Mark Musich; Lucinda Hamre

    2009-01-07

    The primary objective of the project was to evaluate the long-term feasibility of using activated carbon injection (ACI) options to effectively reduce mercury emissions from Texas electric generation plants in which a blend of lignite and subbituminous coal is fired. Field testing of ACI options was performed on one-quarter of Unit 2 at TXU's Big Brown Steam Electric Station. Unit 2 has a design output of 600 MW and burns a blend of 70% Texas Gulf Coast lignite and 30% subbituminous Powder River Basin coal. Big Brown employs a COHPAC configuration, i.e., high air-to-cloth baghouses following cold-side electrostatic precipitators (ESPs), for particulate control. When sorbent injection is added between the ESP and the baghouse, the combined technology is referred to as TOXECON{trademark} and is patented by the Electric Power Research Institute in the United States. Key benefits of the TOXECON configuration include better mass transfer characteristics of a fabric filter compared to an ESP for mercury capture and contamination of only a small percentage of the fly ash with AC. The field testing consisted of a baseline sampling period, a parametric screening of three sorbent injection options, and a month long test with a single mercury control technology. During the baseline sampling, native mercury removal was observed to be less than 10%. Parametric testing was conducted for three sorbent injection options: injection of standard AC alone; injection of an EERC sorbent enhancement additive, SEA4, with ACI; and injection of an EERC enhanced AC. Injection rates were determined for all of the options to achieve the minimum target of 55% mercury removal as well as for higher removals approaching 90%. Some of the higher injection rates were not sustainable because of increased differential pressure across the test baghouse module. After completion of the parametric testing, a month long test was conducted using the enhanced AC at a nominal rate of 1.5 lb/Macf. During

  4. Gravitational Wave Tests of Strong Field General Relativity with Binary Inspirals: Realistic Injections and Optimal Model Selection

    CERN Document Server

    Sampson, Laura; Yunes, Nicolas

    2013-01-01

    We study generic tests of strong-field General Relativity using gravitational waves emitted during the inspiral of compact binaries. Previous studies have considered simple extensions to the standard post-Newtonian waveforms that differ by a single term in the phase. Here we improve on these studies by (i) increasing the realism of injections and (ii) determining the optimal waveform families for detecting and characterizing such signals. We construct waveforms that deviate from those in General Relativity through a series of post-Newtonian terms, and find that these higher-order terms can affect our ability to test General Relativity, in some cases by making it easier to detect a deviation, and in some cases by making it more difficult. We find that simple single-phase post-Einsteinian waveforms are sufficient for detecting deviations from General Relativity, and there is little to be gained from using more complicated models with multiple phase terms. The results found here will help guide future attempts t...

  5. Underground Coal Mine Methane Displacement by Injecting Low-pressure Gas into the Meta-anthracite Seam: Laboratory and Field Tests

    Directory of Open Access Journals (Sweden)

    Yu Hong

    2014-09-01

    Full Text Available Because of the strong adsorption capacity of meta-anthracite, the gas content of a meta-anthracite seam can be as high as 10 m3/t, with a gas pressure lower than 0.74 MPa; this results in low efficiency of gas extraction in underground mines. To enhance low-pressure methane extraction efficiency in meta-anthracite seams, a new approach – methane displacement by gas injection – has been developed, investigated in the laboratory, and then applied in the field in the Fuyanshan coal mine. Laboratory results show that when the gas content of the coal seam is high, methane displacement by nitrogen injection is difficult. The volume of methane displaced is directly related to the pressure difference between the coal seam gas pressure and the injection gas pressure. If the total gas pressure is greater than 0.5 MPa after nitrogen injection, then the methane displacement efficiency will be greatly enhanced. It is also confirmed that the displacement efficiency can be improved by injecting inert gas to change the partial pressure of the methane. Field test data show quite good methane displacement efficiency.

  6. Water injection in various fields of Argentina

    Energy Technology Data Exchange (ETDEWEB)

    1969-10-01

    Two successful pilot flood tests conducted in the Argentine oil fields have been sufficiently successful to indicate to Yacimientos Petroliferos Fiscales (YPF) that many other fields having similar reservoir characteristics would respond well to waterflooding. In 1966, YPF contracted with companies specializing in secondary recovery to make a study of these 4 reservoirs: Canadon Leon, in Santa Cruz, to the south of Comodoro Rivadavia; Barrancas South, in Mendoza; and El Sauce and Cerro Bandera, both in Neuquen (as indicated on the base map). These studies revealed which of the formations were most likely to respond to water injection. For Canadon Leon and Barrancas, pilot operations were recommended, while for the others, water injection on a large scale was recommended. The scheme of large-scale waterflooding for Cerro Bandera (Neuquen) and El Sauce (Neuquen) is illustrated. In Canadon Leon and Barrancas alone, secondary recovery is expected to increase the oil recovery to around 3,500,000 bbl; of this total 1,327,282 is primary and 2,190,000 is secondary recovery. Tabular data show the anticipated results of water injection in the 4 studied fields.

  7. Single well field injection test of humate to enhance attenuation of uranium and other radionuclides in an acidic plume

    Energy Technology Data Exchange (ETDEWEB)

    Denham, M. [Savannah River Site (SRS), Aiken, SC (United States)

    2014-09-30

    This report documents the impact of the injected humate on targeted contaminants over a period of 4 months and suggests it is a viable attenuation-based remedy for uranium, potentially for I-129, but not for Sr-90. Future activities will focus on issues pertinent to scaling the technology to full deployment.

  8. Theory and application of the transient injection well test

    Institute of Scientific and Technical Information of China (English)

    LIU Yuewu; CHEN Huixin; LIU Qingquan; GONG Xin; ZHANG Dawei; YAO Deliang; LI Lianxiang

    2005-01-01

    Based on the theory of the pumping well test, the transient injection well test was suggested in this paper. The design method and the scope of application are discussed in detail. The mathematical models are developed for the short-time and long-time transient injection test respectively. A double logarithm type curve matching method was introduced for analyzing the field transient injection test data. A set of methods for the transient injection test design, experiment performance and data analysis were established. Some field tests were analyzed, and the results show that the test model and method are suitable for the transient injection test and can be used to deal with the real engineering problems.

  9. Lightning Pin Injection Testing on MOSFETS

    Science.gov (United States)

    Ely, Jay J.; Nguyen, Truong X.; Szatkowski, George N.; Koppen, Sandra V.; Mielnik, John J.; Vaughan, Roger K.; Wysocki, Philip F.; Celaya, Jose R.; Saha, Sankalita

    2009-01-01

    Lightning transients were pin-injected into metal-oxide-semiconductor field-effect transistors (MOSFETs) to induce fault modes. This report documents the test process and results, and provides a basis for subsequent lightning tests. MOSFETs may be present in DC-DC power supplies and electromechanical actuator circuits that may be used on board aircraft. Results show that unprotected MOSFET Gates are susceptible to failure, even when installed in systems in well-shielded and partial-shielded locations. MOSFET Drains and Sources are significantly less susceptible. Device impedance decreased (current increased) after every failure. Such a failure mode may lead to cascading failures, as the damaged MOSFET may allow excessive current to flow through other circuitry. Preliminary assessments on a MOSFET subjected to 20-stroke pin-injection testing demonstrate that Breakdown Voltage, Leakage Current and Threshold Voltage characteristics show damage, while the device continues to meet manufacturer performance specifications. The purpose of this research is to develop validated tools, technologies, and techniques for automated detection, diagnosis and prognosis that enable mitigation of adverse events during flight, such as from lightning transients; and to understand the interplay between lightning-induced surges and aging (i.e. humidity, vibration thermal stress, etc.) on component degradation.

  10. Application of Mixed Injection Test Method of Feeder Automation Field Test in Changzhou%混合注入测试法FA现场测试在常州的应用

    Institute of Scientific and Technical Information of China (English)

    秦勇明; 虞坚阳; 王曙宁

    2016-01-01

    馈线自动化现场测试是配电自动化系统验收阶段的重要环节。采用混合注入测试法可以有效提高该环节的测试效率,显著减少对测试人员和测试设备的需求。文章首先系统阐述了该测试方法的主要内容以及测试系统的架构和功能。然后以常州某地区的配电自动化系统现场测试为例,详细介绍了混合注入测试法的测试步骤,实例验证了该方法的有效性。%Field test of feeder automation is the key process of the acceptance phase of distribution automation system. The mixed injection test method can effectively improve the test efficiency and reduce the requirement of the test personnel and test equipment. In this paper,the main content of the test method and the structure and function of the test system is systematically expounded. Taking a site acceptance test of the distribution automation system in Changzhou as an example,the test steps of the mixed injection test method are introduced in detail. The effectiveness of the test method is verified by this application example.

  11. Long-Term Carbon Injection Field Test for 90% Mercury Removal for a PRB Unit a Spray Dryer and Fabric Filter

    Energy Technology Data Exchange (ETDEWEB)

    Sjostrom, Sharon; Amrhein, Jerry

    2009-04-30

    The power industry in the U.S. is faced with meeting regulations to reduce the emissions of mercury compounds from coal-fired plants. Injecting a sorbent such as powdered activated carbon (PAC) into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. The purpose of this test program was to evaluate the long-term mercury removal capability, long-term mercury emissions variability, and operating and maintenance (O&M) costs associated with sorbent injection on a configuration being considered for many new plants. Testing was conducted by ADA Environmental Solutions (ADA) at Rocky Mountain Power’s (RMP) Hardin Station through funding provided by DOE/NETL, RMP, and other industry partners. The Hardin Station is a new plant rated at 121 MW gross that was first brought online in April of 2006. Hardin fires a Powder River Basin (PRB) coal and is configured with selective catalytic reduction (SCR) for NOx control, a spray dryer absorber (SDA) for SO2 control, and a fabric filter (FF) for particulate control. Based upon previous testing at PRB sites with SCRs, very little additional mercury oxidation from the SCR was expected at Hardin. In addition, based upon results from DOE/NETL Phase II Round I testing at Holcomb Station and results from similarly configured sites, low native mercury removal was expected across the SDA and FF. The main goal of this project was met—sorbent injection was used to economically and effectively achieve 90% mercury control as measured from the air heater (AH) outlet to the stack for a period of ten months. This goal was achieved with DARCO® Hg-LH, Calgon FLUEPAC®-MC PLUS and ADA Power PAC PREMIUM brominated activated carbons at nominal loadings of 1.5–2.5 lb/MMacf. An economic analysis determined the twenty-year levelized cost to be 0.87 mills/kW-hr, or $15,000/lb Hg removed. No detrimental effects on other equipment or plant operations were observed. The

  12. Hydrate control for WAG injection in the Ekofisk field

    Energy Technology Data Exchange (ETDEWEB)

    Lekvam, Knut; Surguchev, Leonid M.; Ekrann, Steinar; Svartaas, Thor Martin; Kelland, Malcolm; Nilsson, Svante; Oevsthus, Jorun; Gjoevikli, Nils B.

    1997-12-31

    The report relates to a hydrate formation project for the Ekofisk field on the Norwegian continental shelf. To remove the possible hydrate formation problems during WAG (Water Alternating Gas) treatment, the following project was conducted to estimate roughly the distance from the injection well that hydrate formation can be prevented by whatever treatment is most appropriate. The first aim was to test experimentally whether selected kinetic hydrate inhibitors could be used, and in which concentrations and quantities. In addition evaluations were done to calculate the required volume of the inhibitor solutions that have to be injected to prevent mixing of uninhibited water and gas. 8 figs., 8 tabs.

  13. Long-Term Carbon Injection Field Test for 90% Mercury Removal for a PRB Unit a Spray Dryer and Fabric Filter

    Energy Technology Data Exchange (ETDEWEB)

    Sjostrom, Sharon; Amrhein, Jerry

    2009-04-30

    The power industry in the U.S. is faced with meeting regulations to reduce the emissions of mercury compounds from coal-fired plants. Injecting a sorbent such as powdered activated carbon (PAC) into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. The purpose of this test program was to evaluate the long-term mercury removal capability, long-term mercury emissions variability, and operating and maintenance (O&M) costs associated with sorbent injection on a configuration being considered for many new plants. Testing was conducted by ADA Environmental Solutions (ADA) at Rocky Mountain Power’s (RMP) Hardin Station through funding provided by DOE/NETL, RMP, and other industry partners. The Hardin Station is a new plant rated at 121 MW gross that was first brought online in April of 2006. Hardin fires a Powder River Basin (PRB) coal and is configured with selective catalytic reduction (SCR) for NOx control, a spray dryer absorber (SDA) for SO2 control, and a fabric filter (FF) for particulate control. Based upon previous testing at PRB sites with SCRs, very little additional mercury oxidation from the SCR was expected at Hardin. In addition, based upon results from DOE/NETL Phase II Round I testing at Holcomb Station and results from similarly configured sites, low native mercury removal was expected across the SDA and FF. The main goal of this project was met—sorbent injection was used to economically and effectively achieve 90% mercury control as measured from the air heater (AH) outlet to the stack for a period of ten months. This goal was achieved with DARCO® Hg-LH, Calgon FLUEPAC®-MC PLUS and ADA Power PAC PREMIUM brominated activated carbons at nominal loadings of 1.5–2.5 lb/MMacf. An economic analysis determined the twenty-year levelized cost to be 0.87 mills/kW-hr, or $15,000/lb Hg removed. No detrimental effects on other equipment or plant operations were observed. The

  14. Hydrogeology and results of injection tests at waste-injection test sites in Pinellas County, Florida

    Science.gov (United States)

    Hickey, John J.

    1982-01-01

    Potential benefits or hazards to freshwater resources could result from subsurface injection of treated wastewater. Recognizing this, the U.S. Geological Survey, in cooperation with Pinellas County and the city of St. Petersburg, undertook an evaluation of the hydrogeology and injection of wastewater at proposed test sites on the Pinellas peninsula. The injection sites are underlain by sedimentary rocks ranging in age from Cretaceous to Pleistocene. Lower Eocene carbonate rocks were penetrated to a maximum depth of 3,504 feet and were found to have relatively low water yields. The most permeable part of the investigated section was in rocks of middle Eocene age within the Floridan aquifer. At the injection sites, the Floridan aquifer was subdivided into four permeable zones and three semiconfining beds. The test injection zone is within the Avon Park Limestone, the most productive of the identified permeable zones, with a transmissivity of about 1,000,000 feet squared per day. Two semiconfining beds are above the injection zone in the Suwannee Limestone and Ocala Limestone and have vertical hydraulic conductivities estimated to range from about 0.1 to 1 foot per day where these beds do not contain clay. Limited fresh ground-water supplies exist in the Floridan aquifer within the Pinellas peninsula. At all test sites, chloride concentration in the injection zone ranged from 19,000 to 20,000 milligrams per liter. Injection tests ranging in duration from 3 to 91.1 days were run at three different sites. Pressure buildup occurred in permeable zones above and below the injection zone during these tests. Calculated pressure buildup in observation wells close to and at some distance from the test wells was typically less than 1 pound per square inch. Injection and formation water will probably move slowly through the semiconfining bed overlying the injection zone, and long-term injection tests will be needed to determine the effectiveness of these beds to retard flow. The

  15. Geothermal injection treatment: process chemistry, field experiences, and design options

    Energy Technology Data Exchange (ETDEWEB)

    Kindle, C.H.; Mercer, B.W.; Elmore, R.P.; Blair, S.C.; Myers, D.A.

    1984-09-01

    The successful development of geothermal reservoirs to generate electric power will require the injection disposal of approximately 700,000 gal/h (2.6 x 10/sup 6/ 1/h) of heat-depleted brine for every 50,000 kW of generating capacity. To maintain injectability, the spent brine must be compatible with the receiving formation. The factors that influence this brine/formation compatibility and tests to quantify them are discussed in this report. Some form of treatment will be necessary prior to injection for most situations; the process chemistry involved to avoid and/or accelerate the formation of precipitate particles is also discussed. The treatment processes, either avoidance or controlled precipitation approaches, are described in terms of their principles and demonstrated applications in the geothermal field and, when such experience is limited, in other industrial use. Monitoring techniques for tracking particulate growth, the effect of process parameters on corrosion and well injectability are presented. Examples of brine injection, preinjection treatment, and recovery from injectivity loss are examined and related to the aspects listed above.

  16. Research on the test method of using injection as an equivalent substitute for electromagnetic radiation

    Science.gov (United States)

    Pan, X. D.; Wei, G. H.; Lu, X. F.; Li, K.

    2013-03-01

    This paper presents a method to carry out high intensity radiated field (HIRF) effect experiments by using injection as an equivalent substitute for electromagnetic radiation. In allusion to typical interconnected system, the equal response voltage on the equipment cable port is regarded as an equivalent basis of injection and radiation methods. The equivalent relation formula between injected voltage and radiated field is derived theoretically. The conditions needed for extrapolating injected voltage in HIRF are confirmed, and the extrapolation method is proposed. On the basis of the above research, the electromagnetic environment effect test new method combined injection with radiation for interconnected system is summarized. The typical nonlinear interconnected system is selected as equipment under test, and the single frequency continuous wave radiation and injection effect experiments are carried out separately. The test results indicate that the relation between radiated field and injected voltage is linear, and the equivalent injected voltage used to substitute HIRF can be obtained by linear extrapolation.

  17. Comparison of geochemical data obtained using four brine sampling methods at the SECARB Phase III Anthropogenic Test CO2 injection site, Citronelle Oil Field, Alabama

    Science.gov (United States)

    Conaway, Christopher; Thordsen, James J.; Manning, Michael A.; Cook, Paul J.; Trautz, Robert C.; Thomas, Burt; Kharaka, Yousif K.

    2016-01-01

    The chemical composition of formation water and associated gases from the lower Cretaceous Paluxy Formation was determined using four different sampling methods at a characterization well in the Citronelle Oil Field, Alabama, as part of the Southeast Regional Carbon Sequestration Partnership (SECARB) Phase III Anthropogenic Test, which is an integrated carbon capture and storage project. In this study, formation water and gas samples were obtained from well D-9-8 #2 at Citronelle using gas lift, electric submersible pump, U-tube, and a downhole vacuum sampler (VS) and subjected to both field and laboratory analyses. Field chemical analyses included electrical conductivity, dissolved sulfide concentration, alkalinity, and pH; laboratory analyses included major, minor and trace elements, dissolved carbon, volatile fatty acids, free and dissolved gas species. The formation water obtained from this well is a Na–Ca–Cl-type brine with a salinity of about 200,000 mg/L total dissolved solids. Differences were evident between sampling methodologies, particularly in pH, Fe and alkalinity. There was little gas in samples, and gas composition results were strongly influenced by sampling methods. The results of the comparison demonstrate the difficulty and importance of preserving volatile analytes in samples, with the VS and U-tube system performing most favorably in this aspect.

  18. Cross-field plasma injection into mirror geometry

    Science.gov (United States)

    Uzun-Kaymak, I. U.; Messer, S.; Bomgardner, R.; Case, A.; Clary, R.; Ellis, R.; Elton, R.; Teodorescu, C.; Witherspoon, F. D.; Young, W.

    2009-09-01

    The Maryland Centrifugal Experiment (MCX) and HyperV Technologies Corp. are collaborating on a series of experiments to test the use of a plasma gun to inject mass and momentum into a magnetic-confinement device. HyperV has designed, built and installed a prototype coaxial gun to drive rotation in MCX. The gun has been designed to avoid the blow-by instability via a combination of electrode shaping and a tailored plasma armature. Preliminary measurements at HyperV indicate the gun generates plasma jets with a mass of 160 µg, velocities up to 90 km s-1 and plasma density in the high 1014 cm-3. This paper emphasizes characteristics of the plasma gun and penetration of the plasma jet through the MCX magnetic field. Plans for future injection experiments are briefly discussed.

  19. Ring-shaped velocity distribution functions in energy-dispersed structures formed at the boundaries of a proton stream injected into a transverse magnetic field: Test-kinetic results

    CERN Document Server

    Voitcu, Gabriel

    2016-01-01

    In this paper, we discuss the formation of ring-shaped and gyro-phase restricted velocity distribution functions (VDFs) at the edges of a cloud of protons injected into non-uniform distributions of the electromagnetic field. The velocity distribution function is reconstructed using the forward test-kinetic method. We consider two profiles of the electric field: (1) a non-uniform E-field obtained by solving the Laplace equation consistent with the conservation of the electric drift and (2) a constant and uniform E-field. In both cases, the magnetic field is similar to the solutions obtained for tangential discontinuities. The initial velocity distribution function is Liouville mapped along numerically integrated trajectories. The numerical results show the formation of an energy-dispersed structure due to the energy-dependent displacement of protons towards the edges of the cloud by the gradient-B drift. Another direct effect of the gradient-B drift is the formation of ring-shaped velocity distribution functio...

  20. Relations between open-field, elevated plus-maze, and emergence tests in C57BL/6JIco and BALB/cAnN@Ico mice injected with ethanol.

    Science.gov (United States)

    Lalonde, R; Strazielle, C

    2012-04-01

    The effects of ethanol were examined on three tests of exploratory activity in two mouse strains. Although ethanol reduced open-field rearing in both strains, it increased ambulation only in the less active BALB/cAnN@Ico strain, not in the C57BL/6JIco strain. Likewise, ethanol increased open and enclosed arm entries in the elevated plus-maze only in the more anxious BALB/cAnN@Ico strain. However, both strains injected with ethanol emerged faster than placebo from a small chamber at doses not affecting behaviors in the other two tests. Significant correlations were found between emergence latencies on one hand and either slow stereotyped movements or open and enclosed arm entries on the other. The strain-specific effects may be attributable to differences in GABA(A) -related receptor binding or catalase activity. © 2011 The Authors Fundamental and Clinical Pharmacology © 2011 Société Française de Pharmacologie et de Thérapeutique.

  1. Field and laboratory studies of subsurface water injection: Seasonal Thermal Energy Storage program (STES)

    Science.gov (United States)

    Owen, L. B.; Blair, S. C.; Peterson, E.

    1982-12-01

    The Seasonal Thermal Energy Storage (STES) project office at the Battelle, Pacific Northwest Laboratory has sponsored development of an Aquifer Properties Test Facility (APTF) to evaluate the effects of thermal cycling on reservoir properties. The APTF Laboratory apparatus for testing aquifer materials at elevated temperature and pressure (Figure 1) is now being used to evaluate aquifer material from the University of Minnesota Field Test Facility (FTF). Injection well impairment has been experienced at STES sites in Mobile, Alabama and Stony Brook, New York. Terra Tek Research, under contract to Battelle, PNL, performed a laboratory evaluation of impairment mechanisms that may have been involved in the failure of the injection well at the Stony Brook site. Terra Tek Research, again under contract to Battelle, PNL, designed, built and installed a portable Field Injectability Test Stand (FITS) at the STES Field Test Facility, University of Minnesota, St. Paul, Minnesota. The injectability apparatus uses membrane filters and core samples as injection formation analogs to evaluate the response of a representative porous matrix to injected water.

  2. Results of an injection test using ethyl alcohol as tracer at Los Humeros geothermal field, Puebla, Mexico; Resultados de una prueba de inyeccion de alcohol empleado como trazador, en el campo geotermico de Los humeros, Puebla, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Tovar Aguado, Rigoberto; Lopez Romero, Oscar [Comision Federal de Electricidad, Los Humeros, Puebla (Mexico)

    2000-12-01

    Los Humeros is the third Mexican geothermal field where ethyl alcohol was used as organic tracer to test communication between wells. The first Mexican geothermal field where this kind of test was used Los Azufres, Michoacan. The second was Las Tres Virgenes, Baja California Sur. In both cases, connections between wells were observed. The injection well H-29 is in the north-central sector of Los Humeros geothermal field, Puebla, Mexico. At a depth of 1580 meters, 600 liters of ethyl alcohol was pumped through a 60.35 mm (23/8 inch) diameter tube after 2.7 m{sup 3} of geothermal fluids were displaced, allowing the alcohol to reach the formation. Then, the normal injection process continued with water and condensed steam (130 t/h). On the basis of the experience acquired with similar tests conducted at Las Tres Virgenes geothermal field, and with the goal of detecting the tracer, samples of condensed steam were collected in nearby wells (H-15, H-16, H-17, H-30, H-33, H-36 and H-8) and in distant wells-named special samples (H-32, H-1, H-11, H-12, H-19, H-20, H-35, H-37, H-39, H-6 and H-9). Condensed steam samples were collected every 12 hours, the every week and finally every 15 days, making a total of 592 samples. The chemical analysis were done in two stages because of probable with the chromatograph. In the first stage, 441 samples were run and the rest were run in the second stage. No evidence of the tracer was observed in the monitoring wells. The results confirm the existence of a low-to-moderate permeability, as was previously interpreted using pressure log data. [Spanish] Los Humeros es el tercer campo geotermico de Mexico en el que se realiza una prueba de trazadores organicos empleando alcohol etilico con la finalidad principal de conocer si existe comunicacion entre pozos. El primer campo geotermico en el que se realizo esta prueba fue el de Los Azufres, Michoacan y el segundo el de Las Tres Virgenes, Baja California Sur; en ambos casos se encontro

  3. Development of Improved Oil Field Waste Injection Disposal Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Terralog Technologies

    2002-11-25

    The goals of this project have was to: (1) assemble and analyze a comprehensive database of past waste injection operations; (2) develop improved diagnostic techniques for monitoring fracture growth and formation changes; (3) develop operating guidelines to optimize daily operations and ultimate storage capacity of the target formation; and (4) to apply these improved models and guidelines in the field.

  4. One year update - Chevron's horizontal steam injection test facility

    Energy Technology Data Exchange (ETDEWEB)

    Sims, J.C.; Fram, J.H. [Chevron Energy Technology Company (Canada)

    2011-07-01

    In the heavy oil industry, control of the steam injection profile constitutes an important challenge when using a thermal recovery system in horizontal wells. In general, the measurement of two flow mixtures is complex and to date there is no reliable method for controlling two-phase steam distribution. The purpose of this paper is to provide an update on the results of testing flow splitting and liner isolation devices. These tests have been conducted by Chevron over the last year in a horizontal steam injection test facility built at the Kern River Field close to Bakersfield. This facility also allows Chevron to develop their own equipment for improving steam injection profile. Results show that none of the commercially available devices tested are able to provide consistent steam control. This paper highlighted the results of Chevron's horizontal steam injection test facility and the need for improvement of steam control equipment.

  5. Diabetes Fear of Injecting and Self-Testing Questionnaire

    DEFF Research Database (Denmark)

    Mollema, E D; Snoek, Frank J; Pouwer, F

    2000-01-01

    OBJECTIVE: To study the psychometric properties of the Diabetes Fear of Injecting and Self-Testing Questionnaire (D-FISQ). RESEARCH DESIGN AND METHODS: Two groups of patients were studied. Sample A consisted of 252 insulin-treated diabetes patients. Sample B incorporated 24 insulin-treated patients...... with high scores (> or = 95th percentile) on the D-FISQ. Test-retest correlations were assessed in both samples. Discriminant and convergent validity of the D-FISQ were assessed with questionnaires concerning fear of hypoglycemia, trait anxiety, and fear of bodily injury, illness, or death. To evaluate...... criterion-related validity, sample B participated in a behavioral avoidance test (BAT), in which the current level of avoidance of either self-injecting or self-testing was determined. Exploratory factor analysis (EFA) was performed to study whether 2 factors (fear of self-injecting [FSI] and fear of self...

  6. DUS II SOIL GAS SAMPLING AND AIR INJECTION TEST RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Noonkester, J.; Jackson, D.; Jones, W.; Hyde, W.; Kohn, J.; Walker, R.

    2012-09-20

    Soil vapor extraction (SVE) and air injection well testing was performed at the Dynamic Underground Stripping (DUS) site located near the M-Area Settling Basin (referred to as DUS II in this report). The objective of this testing was to determine the effectiveness of continued operation of these systems. Steam injection ended on September 19, 2009 and since this time the extraction operations have utilized residual heat that is present in the subsurface. The well testing campaign began on June 5, 2012 and was completed on June 25, 2012. Thirty-two (32) SVE wells were purged for 24 hours or longer using the active soil vapor extraction (ASVE) system at the DUS II site. During each test five or more soil gas samples were collected from each well and analyzed for target volatile organic compounds (VOCs). The DUS II site is divided into four parcels (see Figure 1) and soil gas sample results show the majority of residual VOC contamination remains in Parcel 1 with lesser amounts in the other three parcels. Several VOCs, including tetrachloroethylene (PCE) and trichloroethylene (TCE), were detected. PCE was the major VOC with lesser amounts of TCE. Most soil gas concentrations of PCE ranged from 0 to 60 ppmv with one well (VEW-22A) as high as 200 ppmv. Air sparging (AS) generally involves the injection of air into the aquifer through either vertical or horizontal wells. AS is coupled with SVE systems when contaminant recovery is necessary. While traditional air sparging (AS) is not a primary component of the DUS process, following the cessation of steam injection, eight (8) of the sixty-three (63) steam injection wells were used to inject air. These wells were previously used for hydrous pyrolysis oxidation (HPO) as part of the DUS process. Air sparging is different from the HPO operations in that the air was injected at a higher rate (20 to 50 scfm) versus HPO (1 to 2 scfm). . At the DUS II site the air injection wells were tested to determine if air sparging affected

  7. Research on the Equivalence Between Double Differential-mode Current Injection and Radiation Test Method

    Institute of Scientific and Technical Information of China (English)

    PAN Xiaodong; WEI Guanghui; FAN Lisi; LU Xinfu; YANG Zhe

    2013-01-01

    There are the application scope limits for single differential-mode current injection test method,so in order to carry out injection susceptibility test for two-pieces equipment interconnected with both ends of a cable simultaneously,a double differential-mode current injection test method (DDMCI) is proposed.The method adopted the equivalence source wave theorem and Baum-Liu-Tesche (BLT)equation as its theory foundation.The equivalent corresponding relation between injection voltage and radiation electric field intensity is derived,and the phase relation between the two injection voltage sources is confirrned.The results indicate that the amplitude and phase of the equivalent injection voltage source is closely related to the S parameter of directional coupling device,the transmission line length,and the source vector in BLT equation,but has nothing to do with the reflection coefficient between the two equipment pieces.Therefore,by choosing the right amplitude and phase of the double injection voltage sources,the DDMCI test is equivalent to the radiation test for two interconnected equipment of a system.

  8. Testing a fall risk model for injection drug users.

    Science.gov (United States)

    Pieper, Barbara; Templin, Thomas N; Goldberg, Allon

    2012-01-01

    Fall risk is a critical component of clinical assessment and has not been examined for persons who have injected illicit drugs and are aging. The aim of this study was to test and develop the Fall Risk Model for Injection Drug Users by examining the relationships among injection drug use, chronic venous insufficiency, lower extremity impairments (i.e., decreased ankle range of motion, reduced calf muscle endurance, and leg pain), age and other covariates, and the Tinetti balance and gait total score as a measure of fall risk. A cross-sectional comparative design was used with four crossed factors. Standardized instruments were used to assess the variables. Moderated multiple regression with linear and quadratic trends in age was used to examine the nature of the relationship between the Tinetti balance and gait total and age and the potential moderating role of injection drug use. A prespecified series of models was tested. Participants (n = 713) were men (46.9%) and women with a mean age of 46.26 years and primarily African American (61.7%) in methadone treatment centers. The fall risk of a 48-year-old leg injector was comparable with the fall risk of a 69-year-old who had not injected drugs. Variables were added to the model sequentially, resulting in some lost significance of some when they were explained by subsequent variables. Final significant variables in the model were employment status, number of comorbidities, ankle range of motion, leg pain, and calf muscle endurance. Fall risk was associated with route of drug use. Lower extremity impairments accounted for the effects of injection drug use and chronic venous insufficiency on risk for falls. Further understanding of fall risk in injection users is necessary as they age, attempt to work, and participate in activities.

  9. Noise Studies on Injected-Beam Crossed-Field Devices.

    Science.gov (United States)

    1980-11-01

    In the gyrotron, where l magnetron injection guns are used, noise under crossed-field conditions is a limiting factor in the performance of the gun...charge I affected the behavior of the beam. Two factors which seemed to give rise to these effects appeared to be in the noise generated near the cathode...circuit I bars, or 0.270". The essential electrical properties of the meander circuit, the delay ratio (C/ vph ) and coupling impedance at the level of the

  10. Environmental safety of underground injection of oil field brines in Louisiana

    Energy Technology Data Exchange (ETDEWEB)

    Conger, R.M.

    1986-09-01

    Louisiana contains almost 4000 brine injection wells that dispose an estimated 1 billion bbl of brine each year, making underground injection that state's most widely practiced method of oil field brine disposal. Louisiana has had no known contamination of a public water supply from underground brine injection; however, the magnitude of this activity presents a potential for contamination if proper disposal practices are not followed. Following the earliest discovery of oil, the petroleum industry has been improving methods to protect ground-water aquifers from underground injection. Although economic incentives spurred the earliest use of underground injection, the technology has progressed to become a method providing environmental safety to ground-water aquifers. Complex reservoir modeling, developed for use in secondary and enhanced recovery techniques, has been applied to simulate pressure effects and vertical migration potential for underground injection reservoirs. Conventional well designs that allow monitoring of well conditions have replaced older, unreliable designs. Improvements in wireline logging make it possible to test the isolation of injected brines from vertical movement along the well bore.

  11. Report of Field Test Evaluation.

    Science.gov (United States)

    Michigan State Univ., East Lansing. Regional Instructional Materials Center for Handicapped Children and Youth.

    Reported by the Great Lakes Region Special Education Instructional Materials Center are field test evaluation of 18 auditory instructional materials for use with handicapped children who learn best through the auditory modality. Among materials evaluated are a taped program on use of the abacus and a cassette audiotape on bird habits and sounds.…

  12. Ethanol injection of ornamental trees facilitates testing insecticide efficacy against ambrosia beetles (Coleoptera: Curculionidae: Scolytinae).

    Science.gov (United States)

    Reding, Michael E; Oliver, Jason B; Schultz, Peter B; Ranger, Christopher M; Youssef, Nadeer N

    2013-02-01

    Exotic ambrosia beetles are damaging pests in ornamental tree nurseries in North America. The species Xylosandrus crassiusculus (Motshulsky) and Xylosandrus germanus (Blandford) are especially problematic. Management of these pests relies on preventive treatments of insecticides. However, field tests of recommended materials on nursery trees have been limited because of unreliable attacks by ambrosia beetles on experimental trees. Ethanol-injection of trees was used to induce colonization by ambrosia beetles to evaluate insecticides and botanical formulations for preventing attacks by ambrosia beetles. Experiments were conducted in Ohio, Tennessee, and Virginia. Experimental trees injected with ethanol had more attacks by ambrosia beetles than uninjected control trees in all but one experiment. Xylosandrus crassiusculus and X. germanus colonized trees injected with ethanol. In most experiments, attack rates declined 8 d after ethanol-injection. Ethanol-injection induced sufficient pressure from ambrosia beetles to evaluate the efficacy of insecticides for preventing attacks. Trunk sprays of permethrin suppressed cumulative total attacks by ambrosia beetles in most tests. Trunk sprays of the botanical formulations Armorex and Veggie Pharm suppressed cumulative total attacks in Ohio. Armorex, Armorex + Permethrin, and Veggie Pharm + Permethrin suppressed attacks in Tennessee. The bifenthrin product Onyx suppressed establishment of X. germanus in one Ohio experiment, and cumulative total ambrosia beetle attacks in Virginia. Substrate drenches and trunk sprays of neonicotinoids, or trunk sprays of anthranilic diamides or tolfenpyrad were not effective. Ethanol-injection is effective for inducing attacks and ensuring pressure by ambrosia beetles for testing insecticide efficacy on ornamental trees.

  13. In Situ Field Testing of Processes

    Energy Technology Data Exchange (ETDEWEB)

    J. Wang

    2001-12-14

    The purpose of this Analysis/Model Report (AMR) is to update and document the data and subsequent analyses from ambient field-testing activities performed in underground drifts of the Yucca Mountain Site Characterization Project (YMP). This revision updates data and analyses presented in the initial issue of this AMR. This AMR was developed in accordance with the ''Technical Work Plan for Unsaturated Zone (UZ) Flow and Transport Process Model Report'' and ''Technical Work Plan for UZ Flow, Transport, and Coupled Processes Process Model Report. These activities were performed to investigate in situ flow and transport processes. The evaluations provide the necessary framework to: (1) refine and confirm the conceptual model of matrix and fracture processes in the unsaturated zone (UZ) and (2) analyze the impact of excavation (including use of construction water and effect of ventilation) on the UZ flow and transport processes. This AMR is intended to support revisions to ''Conceptual and Numerical Models for UZ Flow and Transport'' and ''Unsaturated Zone Flow and Transport Model Process Model Report''. In general, the results discussed in this AMR are from studies conducted using a combination or a subset of the following three approaches: (1) air-injection tests, (2) liquid-release tests, and (3) moisture monitoring using in-drift sensors or in-borehole sensors, to evaluate the impact of excavation, ventilation, and construction-water usage on the surrounding rocks. The liquid-release tests and air-injection tests provide an evaluation of in situ fracture flow and the competing processes of matrix imbibition. Only the findings from testing and data not covered in the ''Seepage Calibration Model and Seepage Testing Data'' are analyzed in detail in the AMR.

  14. Air injection test on a Kaplan turbine: prototype - model comparison

    Science.gov (United States)

    Angulo, M.; Rivetti, A.; Díaz, L.; Liscia, S.

    2016-11-01

    Air injection is a very well-known resource to reduce pressure pulsation magnitude in turbines, especially on Francis type. In the case of large Kaplan designs, even when not so usual, it could be a solution to mitigate vibrations arising when tip vortex cavitation phenomenon becomes erosive and induces structural vibrations. In order to study this alternative, aeration tests were performed on a Kaplan turbine at model and prototype scales. The research was focused on efficiency of different air flow rates injected in reducing vibrations, especially at the draft tube and the discharge ring and also in the efficiency drop magnitude. It was found that results on both scales presents the same trend in particular for vibration levels at the discharge ring. The efficiency drop was overestimated on model tests while on prototype were less than 0.2 % for all power output. On prototype, air has a beneficial effect in reducing pressure fluctuations up to 0.2 ‰ of air flow rate. On model high speed image computing helped to quantify the volume of tip vortex cavitation that is strongly correlated with the vibration level. The hydrophone measurements did not capture the cavitation intensity when air is injected, however on prototype, it was detected by a sonometer installed at the draft tube access gallery.

  15. Remote field eddy current testing

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Y. M.; Jung, H. K.; Huh, H.; Lee, Y. S.; Shim, C. M

    2001-03-01

    The state-of-art technology of the remote field eddy current, which is actively developed as an electromagnetic non-destructive testing tool for ferromagnetic tubes, is described. The historical background and recent R and D activities of remote-field eddy current technology are explained including the theoretical development of remote field eddy current, such as analytical and numerical approach, and the results of finite element analysis. The influencing factors for actual applications, such as the effect of frequency, magnetic permeability, receiving sensitivity, and difficulties of detection and classification of defects are also described. Finally, two examples of actual application, 1) the gap measurement between pressure tubes and calandria tube in CANDU reactor and, 2) the detection of defects in the ferromagnetic heat exchanger tubes, are described. The future research efforts are also included.

  16. Treatability Test Plan for 300 Area Uranium Stabilization through Polyphosphate Injection

    Energy Technology Data Exchange (ETDEWEB)

    Vermeul, Vincent R.; Williams, Mark D.; Fritz, Brad G.; Mackley, Rob D.; Mendoza, Donaldo P.; Newcomer, Darrell R.; Rockhold, Mark L.; Williams, Bruce A.; Wellman, Dawn M.

    2007-06-01

    The U.S. Department of Energy has initiated a study into possible options for stabilizing uranium at the 300 Area using polyphosphate injection. As part of this effort, PNNL will perform bench- and field-scale treatability testing designed to evaluate the efficacy of using polyphosphate injections to reduced uranium concentrations in the groundwater to meet drinking water standards (30 ug/L) in situ. This technology works by forming phosphate minerals (autunite and apatite) in the aquifer that directly sequester the existing aqueous uranium in autunite minerals and precipitates apatite minerals for sorption and long term treatment of uranium migrating into the treatment zone, thus reducing current and future aqueous uranium concentrations. Polyphosphate injection was selected for testing based on technology screening as part of the 300-FF-5 Phase III Feasibility Study for treatment of uranium in the 300-Area.

  17. Review:Progress in research on mixing techniques for transverse injection flow fields in supersonic crossflows

    Institute of Scientific and Technical Information of China (English)

    Wei HUANG; Li YAN

    2013-01-01

    The transverse injection flow field has an important impact on the flowpath design of scramjet engines.At present a combination of the transverse injection scheme and any other flame holder has been widely employed in hypersonic propulsion systems to promote the mixing process between the fuel and the supersonic freestream;combustion efficiency has been improved thereby,as well as engine thrust.Research on mixing techniques for the transverse injection flow field is summarized from four aspects,namely the jet-to-crossflow pressure ratio,the geometric configuration of the injection port,the number of injection ports,and the injection angle.In conclusion,urgent investigations of mixing techniques of the transverse injection flow field are proposed,especially data mining in the quantitative analytical results for transverse injection flow field,based on results from multi-objective design optimization theory.

  18. University of Minnesota Aquifer Thermal Energy Storage Field Test Facility

    Science.gov (United States)

    Walton, M.; Hoyer, M. C.

    1982-12-01

    The University of Minnesota Aquifer Thermal Energy Storage (ATES) Field Test Facility became operational. Experiments demonstrated that the Franconia-Ironton-Galesville aquifer will accept injection of 300 gpm (18.9 1 sec (-1)) at reasonable pressures with a heat buildup in the injection well of about 44 psi (31.6 m) over 8 days. Heating of the ground water caused precipitation of carbonate in the piping and injection well, but with proper water conditioning, the system will work satisfactorily at elevated temperatures.

  19. Results of an injection test of ethylic alcohol as tracer in the geothermal field Las Tres Virgenes, Baja California Sur, Mexico. Resultados de una prueba de inyeccion de alcohol empleado como trazador en el campo geotermico de Las Tres Virgenes, Baja California Sur, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Tovar Aguado, Rigoberto; Lopez Romero, Oscar (Area de Geoquimica, Residencia Los Humeros, Gerencia de Proyectos Geotermoelectricos de la Comision Federal de Electricidad, Morelia (Mexico))

    1998-05-15

    Los Azufres, Michoacan was the first geothermal field in Mexico where an organic tracer test using ethylic alcohol was conducted to study the hydrologic communication between wells. A similar test was carried out in Las Tres Virgenes, Baja California Sur, obtaining preliminary acceptable results. In Las Tres Virgenes 500 liters of ethylic alcohol were added at the surface to the water injected in the vertical well LV-3. This well is fed by 39.6 ton/h of separated water coming from the directional well LV-4, which was used as monitor. Both wells are located in the same platform. Alcohol was detected twelve hours after the injection and the highest concentration was observed 9 days later.

  20. Analysis of Injection-Backflow Tracer Tests in Fractured Geothermal Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Kocabas, I.; Horne, R.N.

    1987-01-20

    Tracer tests have been an important technique for determining the flow and reservoir characteristics in various rock matrix systems. While the interwell tracer tests are aimed at the characterization of the regions between the wells, single-well injection-backflow tracer tests may be useful tools of preliminary evaluation, before implementing long term interwell tracer tests. This work is concerned with the quantitative evaluation of the tracer return profiles obtained from single well injection-backflow tracer tests. First, two mathematical models of tracer transport through fractures, have been reviewed. These two models are based on two different principles: Taylor Dispersion along the fracture and simultaneous diffusion in and out of the adjacent matrix. Then the governing equations for the transport during the injection-backflow tests have been solved. Finally the results were applied to field data obtained from Raft River and East Mesa geothermal fields. In order to determine the values of the parameters of the models that define the transport mechanisms through fractures a non-linear optimization technique was employed. 26 refs., 10 figs.

  1. Proton Injection into the Fermilab Integrable Optics Test Accelerator (IOTA)

    Energy Technology Data Exchange (ETDEWEB)

    Prebys, Eric [Fermilab; Antipov, Sergey [Chicago U.; Piekarz, Henryk [Fermilab; Valishev, A. [Fermilab

    2015-06-01

    The Integrable Optics Test Accelerator (IOTA) is an experimental synchrotron being built at Fermilab to test the concept of non-linear "integrable optics". These optics are based on a lattice including non-linear elements that satisfies particular conditions on the Hamiltonian. The resulting particle motion is predicted to be stable but without a unique tune. The system is therefore insensitive to resonant instabilities and can in principle store very intense beams, with space charge tune shifts larger than those which are possible in conventional linear synchrotrons. The ring will initially be tested with pencil electron beams, but this poster describes the ultimate plan to install a 2.5 MeV RFQ to inject protons, which will produce tune shifts on the order of unity. Technical details will be presented, as well as simulations of protons in the ring.

  2. Proton Injection into the Fermilab Integrable Optics Test Accelerator (IOTA)

    Energy Technology Data Exchange (ETDEWEB)

    Prebys, Eric [Fermilab; Antipov, Sergey [Chicago U.; Piekarz, Henryk [Fermilab; Valishev, A. [Fermilab

    2015-06-01

    The Integrable Optics Test Accelerator (IOTA) is an experimental synchrotron being built at Fermilab to test the concept of non-linear "integrable optics". These optics are based on a lattice including non-linear elements that satisfies particular conditions on the Hamiltonian. The resulting particle motion is predicted to be stable but without a unique tune. The system is therefore insensitive to resonant instabilities and can in principle store very intense beams, with space charge tune shifts larger than those which are possible in conventional linear synchrotrons. The ring will initially be tested with pencil electron beams, but this poster describes the ultimate plan to install a 2.5 MeV RFQ to inject protons, which will produce tune shifts on the order of unity. Technical details will be presented, as well as simulations of protons in the ring.

  3. Relation between crustal stress field changes and fluid injection at The Geysers geothermal field, California

    Science.gov (United States)

    Martinez, P.; Bohnhoff, M.; Kwiatek, G.

    2012-12-01

    Studying potential spatial and temporal variations of the crustal stress field caused by massive fluid injection during reservoir stimulation is important towards an improved understanding of induced seismicity in different types of reservoirs. However, an accurate and reliable determination of such stress changes is difficult and requires dense local seismic networks with good azimuthal coverage and low magnitude-detection threshold. The Geysers geothermal field is located close to the San Andreas Fault in California, USA. There, induced seismicity associated with the exploitation of the reservoir has been extensively monitored for more than 30 years. While it is evident that seismicity at The Geyser is related to injection and production operations it is difficult to relate the production parameters from individual wells to the spatial and temporal patterns of the crustal stress field and associated seismicity. Earlier attempts to determine the local stress field in the area (Oppenheimer, 1986, J. G. R., 91) estimated the stress orientation by inverting 210 fault plane solutions. He obtained a result that was very consistent with the regional stress field, which might indicate that the regional tectonic stress field dominates over the stresses induced locally by reservoir treatment. In this study we aim at determining potential spatial and temporal variations of the local stress field orientation at The Geysers geothermal site using first motion polarity data provided by a permanent array of 34 stations from Lawrence Berkeley National Laboratory (LBNL) installed in 2007. The network is composed of 3-component short period sensors located at the surface throughout the geothermal field with a sampling frequency of 500 Hz. To determine the stress field orientation we apply different stress inversion methods including non-linear stress inversion algorithms (Abers and Gephart, 2001, J. G. R., 106) with Bayesian uncertainty assessment and a linear approach (Hardebeck

  4. Gravimetric monitoring of the first field-wide steam injection in a fractured carbonate field in Oman - A feasibility study

    NARCIS (Netherlands)

    Glegola, M.; Ditmar, P.; Vossepoel, F.; Arts, R.; Al-Kindy, F.; Klees, R.

    2015-01-01

    Gas-Oil Gravity Drainage is to be enhanced by steam injection in a highly fractured, low permeability carbonate field in Oman. Following a successful pilot, field-wide steam injection is being implemented, first of this type in the world. A dedicated monitoring program has been designed to track cha

  5. Neutral Beam Injection for Plasma and Magnetic FieldDiagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Vainionpaa, Jaakko Hannes; Leung, Ka Ngo; Kwan, Joe W.; Levinton,Fred

    2007-08-01

    At the Lawrence Berkeley National Laboratory (LBNL) adiagnostic neutral beam injection system for measuring plasma parameters,flow velocity, and local magnetic field is being developed. High protonfraction and small divergence is essential for diagnostic neutral beams.In our design, a neutral hydrogen beam with an 8 cm x 11 cm (or smaller)elliptical beam spot at 2.5 m from the end of the extraction column isproduced. The beam will deliver up to 5 A of hydrogen beam to the targetwith a pulse width of ~;1 s, once every 1 - 2 min. The H1+ ion species ofthe hydrogen beamwill be over 90 percent. For this application, we havecompared two types of RF driven multicusp ion sources operating at 13.56MHz. The first one is an ion source with an external spiral antennabehind a dielectric RF-window. The second one uses an internal antenna insimilar ion source geometry. The source needs to generate uniform plasmaover a large (8 cm x 5 cm) extraction area. We expect that the ion sourcewith internal antenna will be more efficient at producing the desiredplasma density but might have the issue of limited antenna lifetime,depending on the duty factor. For both approaches there is a need forextra shielding to protect the dielectric materials from the backstreaming electrons. The source walls will be made of insulator materialsuch as quartz that has been observed to generate plasma with higheratomic fraction than sources with metal walls. The ion beam will beextracted and accelerated by a set of grids with slits, thus forming anarray of 6 sheet-shaped beamlets. The multiple grid extraction will beoptimized using computer simulation programs. Neutralization of the beamwill be done in neutralization chamber, which has over 70 percentneutralization efficiency.

  6. Spin injection in silicon at zero magnetic field

    OpenAIRE

    Grenet, L.; Jamet, M.; Noé, P.; Calvo, V.; Hartmann, J.-M.; Nistor, L. E.; Rodmacq, B.; Auffret, S.; Warin, P.; Samson, Y

    2009-01-01

    International audience; In this letter, we show efficient electrical spin injection into a SiGe based p-i-n light emitting diode from the remanent state of a perpendicularly magnetized ferromagnetic contact. Electron spin injection is carried out through an alumina tunnel barrier from a Co/Pt thin film exhibiting a strong out-of-plane anisotropy. The electron spin polarization is then analyzed through the circular polarization of emitted light. All the light polarization measurements are perf...

  7. Technical and economic feasibility study of flue gas injection in an Iranian oil field

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Ahmadi

    2015-09-01

    The main aim of this research is to investigate various gas injection methods (N2, CO2, produced reservoir gas, and flue gas in one of the northern Persian gulf oil fields by a numerical simulation method. Moreover, for each scenario of gas injection technical and economical considerations are took into account. Finally, an economic analysis is implemented to compare the net present value (NPV of the different gas injection scenarios in the aforementioned oil field.

  8. Interpretation and modeling of a subsurface injection test, 200 East Area, Hanford, Washington

    Energy Technology Data Exchange (ETDEWEB)

    Smoot, J.L. [Pacific Northwest Lab., Richland, WA (United States); Lu, A.H. [Westinghouse Hanford Co., Richland, WA (United States)

    1994-11-01

    A tracer experiment was conducted in 1980 and 1981 in the unsaturated zone in the southeast portion of the Hanford 200 East Area near the Plutonium-Uranium Extraction (PUREX) facility. The field design consisted of a central injection well with 32 monitoring wells within an 8-m radius. Water containing radioactive and other tracers was injected weekly during the experiment. The unique features of the experiment were the documented control of the inputs, the experiment`s three-dimensional nature, the in-situ measurement of radioactive tracers, and the use of multiple injections. The spacing of the test wells provided reasonable lag distribution for spatial correlation analysis. Preliminary analyses indicated spatial correlation on the order of 400 to 500 cm in the vertical direction. Previous researchers found that two-dimensional axisymmetric modeling of moisture content generally underpredicts lateral spreading and overpredicts vertical movement of the injected water. Incorporation of anisotropic hydraulic properties resulted in the best model predictions. Three-dimensional modeling incorporated the geologic heterogeneity of discontinuous layers and lenses of sediment apparent in the site geology. Model results were compared statistically with measured experimental data and indicate reasonably good agreement with vertical and lateral field moisture distributions.

  9. Injection molding lens metrology using software configurable optical test system

    Science.gov (United States)

    Zhan, Cheng; Cheng, Dewen; Wang, Shanshan; Wang, Yongtian

    2016-10-01

    Optical plastic lens produced by injection molding machine possesses numerous advantages of light quality, impact resistance, low cost, etc. The measuring methods in the optical shop are mainly interferometry, profile meter. However, these instruments are not only expensive, but also difficult to alignment. The software configurable optical test system (SCOTS) is based on the geometry of the fringe refection and phase measuring deflectometry method (PMD), which can be used to measure large diameter mirror, aspheric and freeform surface rapidly, robustly, and accurately. In addition to the conventional phase shifting method, we propose another data collection method called as dots matrix projection. We also use the Zernike polynomials to correct the camera distortion. This polynomials fitting mapping distortion method has not only simple operation, but also high conversion precision. We simulate this test system to measure the concave surface using CODE V and MATLAB. The simulation results show that the dots matrix projection method has high accuracy and SCOTS has important significance for on-line detection in optical shop.

  10. Scaleup tests and supporting research for the development of duct injection technology

    Energy Technology Data Exchange (ETDEWEB)

    Gooch, J.P.; Dismukes, E.B.; Dahlin, R.S.; Faulkner, M.G. (Southern Research Inst., Birmingham, AL (United States)); Klett, M.G.; Buchanan, T.L.; Hunt, J.E. (Gilbert/Commonwealth, Inc., Reading, PA (United States))

    1989-05-01

    Gilbert Commonwealth, Southern Research Institute and the American Electric Power Service Corporation have embarked on a program to convert DOE's Duct Injection Test Facility located at the Muskingum River Power Plant of Ohio Power Company to test alternate duct injection technologies. The technologies to be tested include slurry sorbent injection of hydrated lime using dual fluid nozzles, or a rotary atomizer and pneumatic injection of hydrated lime, with flue gas humidification before or after sorbent injection. The literature review and analysis contained in this report is a part of the preparatory effort for the test program.

  11. Test beam results of a heavily irradiated Current Injected Detector (CID)

    CERN Document Server

    Harkonen, J; Tuominen, E; Moilanen, H; Maenpaa, T; Verbitskaya, E; Eremin, V; Czellar, S; Dierlamm, A; Tuovinen, E; Lampen, T; Frey, M; Li, Z; Luukka, P

    2010-01-01

    A heavily irradiated (3 x 10(15) 1 MeV n(eq)/cm(2)) Current Injected Detector (CID) was tested with 225 GeV muon beam at CERN H2 beam line. In the CID concept the current is limited by the space charge. The injected carriers will be trapped by the deep levels and this induces a stable electric field through the entire bulk regardless of the irradiation fluence the detector has been exposed to. The steady-state density of the trapped charge is defined by the balance between the trapping and the emission rates of charge carriers (detrapping). Thus, the amount of charge injection needed for the electric field stabilization depends on the temperature. AC-coupled 16 cm(2) detector was processed on high resistivity n-type magnetic Czochralski silicon, and it had 768 strips, 50 mu m pitch, 10 mu m strip width and 3.9 cm strip length. The beam test was carried out using a silicon beam telescope that is based on the CMS detector readout prototype components, APV25 readout chips, and eight strip sensors made by Hamamat...

  12. The impact of interpreted flow regimes during constant head injection tests on the estimated transmissivity from injection tests and difference flow logging

    Energy Technology Data Exchange (ETDEWEB)

    Hjerne, Calle; Ludvigsson, Jan-Erik; Harrstroem, Johan [Geosigma AB, Uppsala (Sweden)

    2013-04-15

    A large number of constant head injection tests were carried out in the site investigation at Forsmark using the Pipe String System, PSS3. During the original evaluation of the tests the dominating transient flow regimes during both the injection and recovery period were interpreted together with estimation of hydraulic parameters. The flow regimes represent different flow and boundary conditions during the tests. Different boreholes or borehole intervals may display different distributions of flow regimes. In some boreholes good agreement was obtained between the results of the injection tests and difference flow logging with Posiva flow log (PFL) but in other boreholes significant discrepancies were found. The main objective of this project is to study the correlation between transient flow regimes from the injection tests and other borehole features such as transmissivity, depth, geology, fracturing etc. Another subject studied is whether observed discrepancies between estimated transmissivity from difference flow logging and injection tests can be correlated to interpreted flow regimes. Finally, a detailed comparison between transient and stationary evaluation of transmissivity from the injection tests in relation to estimated transmissivity from PFL tests in corresponding sections is made. Results from previous injection tests in 5 m sections in boreholes KFM04, KFM08A and KFM10A were used. Only injection tests above the (test-specific) measurement limit regarding flow rate are included in the analyses. For all of these tests transient flow regimes were interpreted. In addition, results from difference flow logging in the corresponding 5 m test sections were used. Finally, geological data of fractures together with rock and fracture zone properties have been used in the correlations. Flow regimes interpreted from the injection period of the tests are generally used in the correlations but deviations between the interpreted flow regimes from the injection and

  13. Electrically Injected Polariton Lasing from a GaAs-Based Microcavity under Magnetic Field

    KAUST Repository

    Bhattacharya, Pallab

    2012-01-01

    Suppression of relaxation bottleneck and subsequent polariton lasing is observed in a GaAs-based microcavity under the application of a magnetic field. The threshold injection current density is 0.32 A/cm2 at 7 Tesla.

  14. Modeling of CBM production, CO2 injection, and tracer movement at a field CO2 sequestration site

    Energy Technology Data Exchange (ETDEWEB)

    Siriwardane, Hema J.; Bowes, Benjamin D.; Bromhal, Grant S.; Gondle, Raj K.; Wells, Arthur W.; Strazisar, Brian R.

    2012-07-01

    Sequestration of carbon dioxide in unmineable coal seams is a potential technology mainly because of the potential for simultaneous enhanced coalbed methane production (ECBM). Several pilot tests have been performed around the globe leading to mixed results. Numerous modeling efforts have been carried out successfully to model methane production and carbon dioxide (CO{sub 2}) injection. Sensitivity analyses and history matching along with several optimization tools were used to estimate reservoir properties and to investigate reservoir performance. Geological and geophysical techniques have also been used to characterize field sequestration sites and to inspect reservoir heterogeneity. The fate and movement of injected CO{sub 2} can be determined by using several monitoring techniques. Monitoring of perfluorocarbon (PFC) tracers is one of these monitoring technologies. As a part of this monitoring technique, a small fraction of a traceable fluid is added to the injection wellhead along with the CO{sub 2} stream at different times to monitor the timing and location of the breakthrough in nearby monitoring wells or offset production wells. A reservoir modeling study was performed to simulate a pilot sequestration site located in the San Juan coal basin of northern New Mexico. Several unknown reservoir properties at the field site were estimated by modeling the coal seam as a dual porosity formation and by history matching the methane production and CO{sub 2} injection. In addition to reservoir modeling of methane production and CO{sub 2} injection, tracer injection was modeled. Tracers serve as a surrogate for determining potential leakage of CO{sub 2}. The tracer was modeled as a non-reactive gas and was injected into the reservoir as a mixture along with CO{sub 2}. Geologic and geometric details of the field site, numerical modeling details of methane production, CO{sub 2} injection, and tracer injection are presented in this paper. Moreover, the numerical

  15. Characterization of injection wells in a fractured reservoir using PTS logs, Steamboat Hills Geothermal Field, Nevada, USA

    Energy Technology Data Exchange (ETDEWEB)

    Goranson, Colin; Combs, Jim

    1995-01-26

    The Steamboat Hills Geothermal Field in northwestern Nevada, about 15 km south of Reno, is a shallow (150m to 825m) moderate temperature (155 C to 168 C) liquid-dominated geothermal reservoir situated in highly-fractured granodiorite. Three injection wells were drilled and completed in granodiorite to dispose of spent geothermal fluids from the Steamboat II and III power plants (a 30 MW air-cooled binary-type facility). Injection wells were targeted to depths below 300m to inject spent fluids below producing fractures. First, quasi-static downhole pressure-temperature-spinner (PTS) logs were obtained. Then, the three wells were injection-tested using fluids between 80 C and 106 C at rates from 70 kg/s to 200 kg/s. PTS logs were run both up and down the wells during these injection tests. These PTS surveys have delineated the subsurface fracture zones which will accept fluid. The relative injectivity of the wells was also established. Shut-in interzonal flow within the wells was identified and characterized.

  16. Acupuncture injection for field amplified sample stacking and glass microchip-based capillary gel electrophoresis.

    Science.gov (United States)

    Ha, Ji Won; Hahn, Jong Hoon

    2017-02-01

    Acupuncture sample injection is a simple method to deliver well-defined nanoliter-scale sample plugs in PDMS microfluidic channels. This acupuncture injection method in microchip CE has several advantages, including minimization of sample consumption, the capability of serial injections of different sample solutions into the same microchannel, and the capability of injecting sample plugs into any desired position of a microchannel. Herein, we demonstrate that the simple and cost-effective acupuncture sample injection method can be used for PDMS microchip-based field amplified sample stacking in the most simplified straight channel by applying a single potential. We achieved the increase in electropherogram signals for the case of sample stacking. Furthermore, we present that microchip CGE of ΦX174 DNA-HaeⅢ digest can be performed with the acupuncture injection method on a glass microchip while minimizing sample loss and voltage control hardware. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. ANTIVIRAL TESTS OF METHYLENE BLUE INJECTION ON VZV IN VITRO

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    Methylene blue injection has a stronger direct inactivation on VZV in vitro. When the injection was diluted from 1:16 to 1:128, which was obvious (P<0.01 and P<0.05). The MIC was 1:222, the IC50 was 1:135 and IC90 was 1:77. The results of microcellculture method showed when the injection was diluted from 1:16 to 1:64, it also effectively inhibited the proliferation of VZV in WISH continuous cell-lines (P<0.01 and P<0.05). The MIC was 1:95, the IC50 was 1:45 and the IC90 was 1:21.

  18. Improving Regression Testing through Modified Ant Colony Algorithm on a Dependency Injected Test Pattern

    Directory of Open Access Journals (Sweden)

    G.Keerthi Lakshmi

    2012-03-01

    Full Text Available Performing regression testing on a pre production environment is often viewed by software practitioners as a daunting task since often the test execution shall by-pass the stipulated downtime or the test coverage would be non linear. Choosing the exact test cases to match this type of complexity not only needs prior knowledge of the system, but also a right use of calculations to set the goals right. On systems that are just entering the production environment after getting promoted from the staging phase, trade-offs are often needed to between time and the test coverage to ensure the maximum test cases are covered within the stipulated time. There arises a need to refine the test cases to accommodate the maximum test coverage it makes within the stipulated period of time since at most of the times, the most important test cases are often not deemed to qualify under the sanity test suite and any bugs that creped in them would go undetected until it is found out by the actual user at firsthand. Hence An attempt has been made in the paper to layout a testing framework to address the process of improving the regression suite by adopting a modified version of the Ant Colony Algorithm over and thus dynamically injecting dependency over the best route encompassed by the ant colony.

  19. CHARM Facility Test Area Radiation Field Description

    CERN Document Server

    Thornton, Adam

    2016-01-01

    Specification document summarising the radiation field of the CHARM facility test area. This will act as a guide to any potential users of the facility as to what they can expect in terms of radiation, given in the form of radiation spectra information and fluence for each test position, along with general radiation maps for the test area and Montrac test location.

  20. Reactivity of Hontomín carbonate rocks to acidic solution injection: reactive "push-pull" tracer tests results

    Science.gov (United States)

    De Gaspari, Francesca; Cabeza, Yoar; Luquot, Linda; Rötting, Tobias; Saaltink, Maarten W.; Carrera, Jesus

    2014-05-01

    Several field tests will be carried out in order to characterize the reservoir for CO2 injection in Hontomín (Burgos, Spain) as part of the Compostilla project of "Fundación Ciudad de la Energía" (CIUDEN). Once injected, the dissolution of the CO2 in the resident brine will increase the acidity of the water and lead to the dissolution of the rocks, constituted mainly by carbonates. This mechanism will cause changes in the aquifer properties such as porosity and permeability. To reproduce the effect of the CO2 injection, a reactive solution with 2% of acetic acid is going to be injected in the reservoir and extracted from the same well (reactive "push-pull" tracer tests) to identify and quantify the geochemical reactions occurring into the aquifer. The reactivity of the rock will allow us also to evaluate the changes of its properties. Previously, theoretical calculations of Damkhöler numbers were done to determine the acid concentrations and injection flow rates needed to generate ramified-wormholes patterns, during theses "push-pull" experiments. The aim of this work is to present the results and a preliminary interpretation of the field tests.

  1. Injection molded nanofluidic chips: Fabrication method and functional tests using single-molecule DNA experiments

    DEFF Research Database (Denmark)

    Utko, Pawel; Persson, Karl Fredrik; Kristensen, Anders;

    2011-01-01

    We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels.......We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels....

  2. Test fields cannot destroy extremal black holes

    Science.gov (United States)

    Natário, José; Queimada, Leonel; Vicente, Rodrigo

    2016-09-01

    We prove that (possibly charged) test fields satisfying the null energy condition at the event horizon cannot overspin/overcharge extremal Kerr-Newman or Kerr-Newman-anti de Sitter black holes, that is, the weak cosmic censorship conjecture cannot be violated in the test field approximation. The argument relies on black hole thermodynamics (without assuming cosmic censorship), and does not depend on the precise nature of the fields. We also discuss generalizations of this result to other extremal black holes.

  3. Magnetohydrodynamic simulations of noninductive helicity injection in the reversed-field pinch and tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Sovinec, C.R.

    1995-12-31

    Numerical computation is used to investigate resistive magnetohydrodynamic (MHD) fluctuations in the reversed-field pinch (RFP) and in tokamak-like configurations driven solely by direct current (DC) helicity injection. A Lundquist number (S) scan of RFP turbulence without plasma pressure produces the weak scaling of S{sup -0.18} for the root-mean-square magnetic fluctuation level for 2.5x10{sup 3}{le}S{le}4x10{sup 4}. The temporal behavior of fluctuations and the reversal parameter becomes more regular as S is increased, acquiring a {open_quotes}sawtooth{close_quotes} shape at the largest value of S. Simulations with plasma pressure and anisotropic thermal conduction demonstrate energy transport resulting from parallel heat fluctuations. To investigate means of improving RFP energy confinement, three forms of current profile modification are tested. Radio frequency (RF) current drive is modeled with an auxiliary electron force, and linear stability calculations are used.

  4. Magnetohydrodynamic simulations of noninductive helicity injection in the reversed-field pinch and tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Sovinec, Carl R. [Univ. of Wisconsin, Madison, WI (United States)

    1995-11-01

    Numerical computation is used to investigate resistive magnetohydrodynamic (MHD) fluctuations in the reversed-field pinch (RFP) and in tokamak-like configurations driven solely by direct current (DC) helicity injection. A Lundquist number (S) scan of RFP turbulence without plasma pressure produces the weak scaling of S-0.18 for the root-mean-square magnetic fluctuation level for 2.5x103≤S≤4x104. The temporal behavior of fluctuations and the reversal parameter becomes more regular as S is increased, acquiring a "sawtooth" shape at the largest value of S. Simulations with plasma pressure and anisotropic thermal conduction demonstrate energy transport resulting from parallel heat fluctuations. To investigate means of improving RFP energy confinement, three forms of current profile modification are tested. Radio frequency (RF) current drive is modeled with an auxiliary electron force, and linear stability calculations are used.

  5. Analysis of tests of subsurface injection, storage, and recovery of freshwater in the lower Floridan aquifer, Okeechobee County, Florida

    Science.gov (United States)

    Quinones-Aponte, Vicente; Kotun, Kevin; Whitley, J.F.

    1996-01-01

    injected water and would represent a mix of water from the different high-permeability zones. A generalized digital model was constructed to simulate the subsurface injection, storage, and recovery of freshwater in the Lower Floridan aquifer at the Lake Okeechobee injection-well site. The model was constructed using a modified version of the Saturated-Unsaturated TRAnsport code (SUTRA), which simulates variable-density advective-dispersive solute transport and variable-density ground-water flow. Satisfactory comparisons of simulated to observed dimensionless chloride concentrations for the deep monitor well were obtained when using the model during the injection and recovery phases of cycle 1, but not for the injection well during the recovery phase of cycle 1 even after several attempts. This precluded the determination of the recovery efficiency values by using the model. The unsatisfactory comparisons of simulated to observed dimensionless chloride concentrations for the injection well and failure of the model to represent the field data at this well could be due to the characteristics of the Lower Floridan aquifer (at the local scale), which is cavernous or conduit in nature. To test this possibility, Reynolds numbers were estimated at varying distances from the injection well, taking into consideration two aquifer types or conceptual systems, porous media and cavernous. For the porous media conceptual system, the Reynolds numbers were greater than 10 at distances less than 1.42 meters from the injection well. Thus, application of Darcy's law to ground-water flow might not be valid at this distance. However, at the deep monitor well (171 meters from the injection well), the Reynolds number was 0.08 which is indicative of laminar porous media flow. For the cavernous conceptual system, the Reynolds numbers were greater than 2,000 at distances less than 1,000 meters from the well. This number represents the upper limit of laminar flow, which is the fundamental assumption

  6. Temporal static stress drop variations due to injection activity at The Geysers geothermal field, California

    Science.gov (United States)

    Staszek, M.; Orlecka-Sikora, B.; Leptokaropoulos, K.; Kwiatek, G.; Martínez-Garzón, P.

    2017-07-01

    We use a high-quality data set from the NW part of The Geysers geothermal field to determine statistical significance of temporal static stress drop variations and their relation to injection rate changes. We use a group of 322 seismic events which occurred in the proximity of Prati-9 and Prati-29 injection wells to examine the influence of parameters such as moment magnitude, focal mechanism, hypocentral depth, and normalized hypocentral distances from open-hole sections of injection wells on static stress drop changes. Our results indicate that (1) static stress drop variations in time are statistically significant, (2) statistically significant static stress drop changes are inversely related to injection rate fluctuations. Therefore, it is highly expected that static stress drop of seismic events is influenced by pore pressure in underground fluid injection conditions and depends on the effective normal stress and strength of the medium.

  7. Experimental investigation of axial plasma injection into a magnetic dipole field

    DEFF Research Database (Denmark)

    Jensen, Vagn Orla

    1968-01-01

    A high-density helium plasma, accelerated from a conical pinch, is injected axially into a magnetic dipole field. Magnetic probe measurements show that, near the axis, a compression of the field is super-imposed on the standard diamagnetic depression. The compression starts downstream and moves...

  8. Effect of gas field production and CO2 injection on brine flow and salt precipitation

    NARCIS (Netherlands)

    Loeve, D.; Tambach, T.J.; Hofstee, C.; Plug, W.J.; Maas, J.

    2012-01-01

    This paper reports modeling of gas field produc-tion and CO2 injection from a theoretical reser-voir based on characteristics of the P18 gas field in the Dutch offshore, which consists of four geological deposits with different petrophysical properties. We especially focus on the brine flow during

  9. Effect of CO2 injection on brine flow and salt precipitation after gas field production

    NARCIS (Netherlands)

    Tambach, T.J.; Loeve, D.; Hofstee, C.; Plug, W.J.; Maas, J.G.

    2014-01-01

    This paper reports modeling of gas field production and CO2 injection in a theoretical reservoir based on characteristics of the P18 gas field in the Dutch offshore, which consists of four geological deposits with different petrophysical properties. We especially focus on the brine flow during and

  10. Transverse field-induced nucleation pad switching modes during domain wall injection

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, M. T.; Fry, P. W.; Schrefl, T.; Gibbs, M. R. J.; Allwood, D. A.; Im, M.-Y.; Fischer, P.

    2010-03-12

    We have used magnetic transmission X-ray microscopy (M-TXM) to image in-field magnetization configurations of patterned Ni{sub 80}Fe{sub 20} domain wall 'injection pads' and attached planar nanowires. Comparison with micromagnetic simulations suggests that the evolution of magnetic domains in rectangular injection pads depends on the relative orientation of closure domains in the remanent state. The magnetization reversal pathway is also altered by the inclusion of transverse magnetic fields. These different modes explain previous results of domain wall injection into nanowires. Even more striking was the observation of domain walls injecting halfway across the width of wider (>400 nm wide) wires but over wire lengths of several micrometers. These extended Neel walls can interact with adjacent nanowires and cause a switching in the side of the wire undergoing reversal as the domain wall continues to expand.

  11. Impact of continuous particle injection on generation and decay of the magnetic field in collisionless shocks

    Science.gov (United States)

    Garasev, Mikhail; Derishev, Evgeny

    2016-09-01

    We present numerical simulations of the magnetic field turbulence in a collisionless electron-positron plasma with continuous injection of new pairs, which maintains the anisotropy in the particle distribution over a long time. With these simulations, we follow the evolution of a small (and, therefore, uniform) region in the fluid comoving frame to model the generation and decay of the magnetic field in shocks. The upstream is modified by two-photon pair production due to self-absorption of the shock's high-energy radiation. We find that the overall picture of the magnetic field build-up is consistent with the development of Weibel instability. However, the long-term injection of anisotropic pairs in the upstream leads to the formation of large-scale structures in the magnetic field, while small-scale structures are almost absent. We find that being amplified at the shock front, this magnetic field mostly preserves its large spatial scale and then slowly decays in the downstream on a time-scale approximately equal to the duration of the injection phase. The observed decay of the magnetic field is in exceptionally good agreement with predictions of the so-called phase mixing model. The generation of a long-lived magnetic field in relativistic collisionless shocks with an injection-modified upstream explains how they can efficiently produce the synchrotron radiation in gamma-ray bursts.

  12. Gas injection may have triggered earthquakes in the Cogdell oil field, Texas.

    Science.gov (United States)

    Gan, Wei; Frohlich, Cliff

    2013-11-19

    Between 1957 and 1982, water flooding was conducted to improve petroleum production in the Cogdell oil field north of Snyder, TX, and a contemporary analysis concluded this induced earthquakes that occurred between 1975 and 1982. The National Earthquake Information Center detected no further activity between 1983 and 2005, but between 2006 and 2011 reported 18 earthquakes having magnitudes 3 and greater. To investigate these earthquakes, we analyzed data recorded by six temporary seismograph stations deployed by the USArray program, and identified 93 well-recorded earthquakes occurring between March 2009 and December 2010. Relocation with a double-difference method shows that most earthquakes occurred within several northeast-southwest-trending linear clusters, with trends corresponding to nodal planes of regional focal mechanisms, possibly indicating the presence of previously unidentified faults. We have evaluated data concerning injection and extraction of oil, water, and gas in the Cogdell field. Water injection cannot explain the 2006-2011 earthquakes, especially as net volumes (injection minus extraction) are significantly less than in the 1957-1982 period. However, since 2004 significant volumes of gases including supercritical CO2 have been injected into the Cogdell field. The timing of gas injection suggests it may have contributed to triggering the recent seismic activity. If so, this represents an instance where gas injection has triggered earthquakes having magnitudes 3 and larger. Further modeling studies may help evaluate recent assertions suggesting significant risks accompany large-scale carbon capture and storage as a strategy for managing climate change.

  13. Charge injection in solution-processed organic field-effect transistors: physics, models and characterization methods.

    Science.gov (United States)

    Natali, Dario; Caironi, Mario

    2012-03-15

    A high-mobility organic semiconductor employed as the active material in a field-effect transistor does not guarantee per se that expectations of high performance are fulfilled. This is even truer if a downscaled, short channel is adopted. Only if contacts are able to provide the device with as much charge as it needs, with a negligible voltage drop across them, then high expectations can turn into high performances. It is a fact that this is not always the case in the field of organic electronics. In this review, we aim to offer a comprehensive overview on the subject of current injection in organic thin film transistors: physical principles concerning energy level (mis)alignment at interfaces, models describing charge injection, technologies for interface tuning, and techniques for characterizing devices. Finally, a survey of the most recent accomplishments in the field is given. Principles are described in general, but the technologies and survey emphasis is on solution processed transistors, because it is our opinion that scalable, roll-to-roll printing processing is one, if not the brightest, possible scenario for the future of organic electronics. With the exception of electrolyte-gated organic transistors, where impressively low width normalized resistances were reported (in the range of 10 Ω·cm), to date the lowest values reported for devices where the semiconductor is solution-processed and where the most common architectures are adopted, are ∼10 kΩ·cm for transistors with a field effect mobility in the 0.1-1 cm(2)/Vs range. Although these values represent the best case, they still pose a severe limitation for downscaling the channel lengths below a few micrometers, necessary for increasing the device switching speed. Moreover, techniques to lower contact resistances have been often developed on a case-by-case basis, depending on the materials, architecture and processing techniques. The lack of a standard strategy has hampered the progress of the

  14. A simple device to inject indicator gas for wash-out tests during mechanical ventilation

    NARCIS (Netherlands)

    I. Gultuna; P.E.M. Huygen; C. Jabaaij (C.); W.P. Holland (Wim); C. Ince (Can); H.A. Bruining (Hajo)

    1992-01-01

    textabstractObjective: To evaluate a simple device which injects a constant fraction of indicator gas to the inspiratory mixture for performing multi-breath wash-out tests during controlled ventilation. Design: the technique in which the indicator gas is injected at the mouth of the patient (post-mi

  15. Field Guide to Interferometric Optical Testing

    CERN Document Server

    Goodwin, Eric P

    2006-01-01

    A distillation of Dr. Wyant's course at the University of Arizona, this Field Guide covers the key fundamentals of interferometry, types of interferometers and interferograms, concepts of phase-shifting interferometry, long-wavelength interferometry, testing of aspheric surfaces, measurement of surface microstructure, flat and curved surface testing, and absolute measurements.

  16. Particle tracking study of the injection process with field interferences in a rapid cycling synchrotron

    Directory of Open Access Journals (Sweden)

    M. J. Shirakata

    2008-06-01

    Full Text Available The large-bore magnets in the injection system of a high-intensity proton synchrotron are placed close to each other as compared to their bore sizes. In such cases, the magnetic cores interfere with the fringe fields of adjacent magnets. Moreover, the incoming beam passes through several kinds of time-varying fields along the injection line and the nonlinear field region of the ring quadrupole magnet. The beam behavior under these conditions is analyzed by using the Runge-Kutta method. Although the interference of the magnetic fields does not result in emittance growth, it produces a closed-orbit distortion. Field fluctuations of the time-varying field cause an emittance growth and the nonlinear field deforms the beam profile in phase space of the incoming beam. These effects lead to the modification of the injection scheme. This study focuses on the particle tracking with magnetic field interferences during the early stage of beam commissioning, when the space charge force is not important.

  17. A Flow Injection Dissolution Testing System and Its Application

    Institute of Scientific and Technical Information of China (English)

    Jiagen Lv; Xiaowei Sheng; Dadong Zhan; Yue Hu; Zhiqi Zhang

    2003-01-01

    @@ The determination of the release rate of drugs is essential for the development of testing new dosage forms and for quality control in pharmaceutical industries. Dissolution testing of pharmaceutical dosage forms is a laborious process that generates large number of samples.

  18. Neutral Beam Injection System for the C-2W Field Reversed Configuration Experiment

    Science.gov (United States)

    Dunaevsky, Alexander; Ivanov, Alexander; Kolmogorov, Vyacheslav; Smirnov, Artem; Korepanov, Sergey; Binderbauer, Michl; TAE Team; BINP Team

    2016-10-01

    C-2U Field-Reversed Configuration (FRC) experiment proved substantial reduction in turbulence-driven losses via tangential neutral beam injection (NBI) coupled with electrically biased plasma guns at the plasma ends. Under such conditions, highly reproducible, advanced beam-driven FRCs were produced and sustained for times significantly longer (more than 5 ms) than all characteristic plasma decay times without beams. To further improve FRC sustainment and demonstrate the FRC ramp-up, the C-2U experimental device is undergoing a major upgrade. The upgrade, C-2W, will have a new NBI system producing a record total hydrogen beam power of 20 + MW in a 30ms pulse. The NBI system consists of eight positive-ion based injectors featuring flexible, modular design. Four out of eight NBI injectors have a capability to switch the beam energy during a shot from the initial 15 keV to 40 keV at a constant beam current. This feature allows to increase the beam energy and thereby optimize the beam-plasma coupling during the magnetic field ramp up. This presentation provides an overview of the C-2W NBI system, including the design of the switchable energy injectors, layout of the power supply system, and results of the prototype testing.

  19. Effect of self-injection on ultraintense laser wake-field acceleration.

    Science.gov (United States)

    Zhidkov, A; Koga, J; Kinoshita, K; Uesaka, M

    2004-03-01

    The self-injection of plasma electrons which have been accelerated to relativistic energies by a laser pulse moving with a group velocity less than the speed of light with I lambda(2)>5 x 10(19) W microm(2)/cm(2) is found via particle-in-cell simulation to be efficient for laser wake-field acceleration. When the matching condition a(0)> or =(2(1/4)omega/omega(pl))(2/3) is met, the self-injection, along with wave breaking, dominates monoenergetic electron acceleration yielding up to 100 MeV energies by a 100 TW, 20 fs laser pulse. In contrast to the injection due to wave-breaking processes, self-injection allows suppression of production of a Maxwell distribution of accelerated particles and the extraction of a beam-quality bunch of energetic electrons.

  20. Rapid Field Toxicity Test for Water Supplies

    Science.gov (United States)

    1994-02-28

    of trichothecenes (2). The correlation of the novel method with the Mysid trichothecenes paper described a perfect qualitative shrimp test, using fresh...test designed for human or animal consumption. organisms in a standard time LED light emitting diode CONCLUSION ml milliliter ppm parts per million A...potassium. of Trichothecenes ," Naval Research Laboratory Memorwdm Report 5738 (March 1986) Logistics dictate a day or so to test field samples in the

  1. Impact of supercritical CO2 injection on petrophysical and rock mechanics properties of chalk: an experimental study on chalk from South Arne field, North Sea

    DEFF Research Database (Denmark)

    Alam, Mohammad Monzurul; Hjuler, Morten Leth; Christensen, Helle Foged

    2011-01-01

    Changes in chalk due to EOR by injecting supercritical CO2 (CO2-EOR) can ideally be predicted by applying geophysical methods designed from laboratory-determined petrophysical and rock mechanics properties. A series of petrophysical and rock mechanics tests were performed on Ekofisk Formation...... and Tor Formation chalk of the South Arne field to reveal the changes in petrophysical and rock mechanics properties of chalk due to the injection of CO2 at supercritical state. An increase in porosity and decrease in specific surface was observed due to injection of supercritical CO2. This indicates...... as indicated by NMR T2 relaxation time was observed. Rock mechanics testing indicates that in 30% porosity chalk from the South Arne field, injection of supercritical CO2 has no significant effect on shear strength and compaction properties, while there is probably a slight decrease in stiffness properties...

  2. Background field coils for the High Field Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Zbasnik, J.P.; Cornish, D.N.; Scanlan, R.M.; Jewell, A.M.; Leber, R.L.; Rosdahl, A.R.; Chaplin, M.R.

    1980-09-22

    The High Field Test Facility (HFTF), presently under construction at LLNL, is a set of superconducting coils that will be used to test 1-m-o.d. coils of prototype conductors for fusion magnets in fields up to 12 T. The facility consists of two concentric sets of coils; the outer set is a stack of Nb-Ti solenoids, and the inner set is a pair of solenoids made of cryogenically-stabilized, multifilamentary Nb/sub 3/Sn superconductor, developed for use in mirror-fusion magnets. The HFTF system is designed to be parted along the midplane to allow high-field conductors, under development for Tokamak fusion machines, to be inserted and tested. The background field coils were wound pancake-fashion, with cold-welded joints at both the inner and outer diameters. Turn-to-turn insulation was fabricated at LLNL from epoxy-fiberglass strip. The coils were assembled and tested in our 2-m-diam cryostat to verify their operation.

  3. Combustion Safety Simplified Test Protocol Field Study

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L. [Gas Technology Inst., Des Plaines, IL (United States); Cautley, D. [Gas Technology Inst., Des Plaines, IL (United States); Bohac, D. [Gas Technology Inst., Des Plaines, IL (United States); Francisco, P. [Gas Technology Inst., Des Plaines, IL (United States); Shen, L. [Gas Technology Inst., Des Plaines, IL (United States); Gloss, S. [Gas Technology Inst., Des Plaines, IL (United States)

    2015-11-01

    Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project team collected field data on 11 houses in 2015.

  4. Some Tests on Heather Field Moraine Clay

    DEFF Research Database (Denmark)

    Jørgensen, Mogens B.; Jacobsen, Moust

    This report deals with oedometer tests on three samples of moraine clay from the Heather Field in the English part of the North Sea. The tests have been carried out in the very unelastic apparatus used in Denmark and with special test procedures differing from the ones used elsewhere. In Denmark...... the English North Sea moraine clays with the corresponding Danish Moraine Clays. The Danish test procedures are explained in details and some comments are given in the hope that they may not be banalities all of them....

  5. Impact of continuous particle injection on generation and decay of the magnetic field in collisionless shocks

    CERN Document Server

    Garasev, Mikhail

    2016-01-01

    We present numerical simulations of the magnetic field turbulence in collisionless electron-positron plasma with continuous injection of new pairs, which maintains anisotropy in the particle distribution over long time. With these simulations we model generation and decay of the magnetic field in shocks, where the upstream is modified by two-photon pair production due to self-absorption of the shock's high-energy radiation. We find that the overall picture of magnetic field build-up is consistent with development of Weibel instability. However, the long-term injection of anisotropic pairs in the upstream leads to formation of large-scale structures in the magnetic field, while the small-scale structures are almost absent. Furthermore, we find that being amplified at the shock front this magnetic field mostly preserves its large spatial scale and then slowly decays in the downstream on a timescale approximately equal to duration of the injection phase. We observe that the decay of the magnetic field is in exce...

  6. Aperture and Field Constraints for the Vacuum System in the LHC Injection Septa

    CERN Document Server

    Gyr, Marcel; Jiménez, J M; Lacroix, Jean Michel; Sgobba, Stefano

    2005-01-01

    Each beam arriving from the SPS has to pass through five injection septum magnets before being kicked onto the LHC orbit. The injection layout implies that the vacuum chambers for the two circulating beams pass through the septum magnet yokes at a flange distance from the chamber of the beam to be injected. Specially designed vacuum chambers and interconnections provide the required straightness and alignment precision, thus optimising the aperture for both the circulating and injected beams, without affecting the quality of the magnetic dipole field seen by the injected beam. The circulating beams are shielded against the magnetic stray field by using µ-metal chambers with a thickness of 0.9 mm to avoid saturation of the µ-metal (0.8 T), coated with copper (0.4 mm) for impedance reasons and NEG for pumping and electron cloud purposes. A 2 mm gap between the iron yoke and the µ-metal chamber allows an in-situ bake-out at 200°C, based on a polyimide/stainless steel/polyimide sandwich structure with an over...

  7. Simulation of A Substorm Dispersionless Injection Using Dynamic Pulse Fields With Varying Propagating Speeds

    Science.gov (United States)

    Sarris, T.; Li, X.

    Energetic electron and ion injections are a common characteristic of substorms and are often observed near or inside geosynchronous orbit. Depending on the local time of measurement these injections can appear to be dispersionless. We performed a sim- ulation of an electron dispersionless injection by considering the interaction of an Earthward propagating electromagnetic pulse with the preexisting electron popula- tion. Such simulations have been performed previously [Li et al., 1993, 1998] and the dispersionless nature of injections measured at geostationary orbit has been repro- duced. These simulations assumed a constant propagation speed for the field configu- ration that produced the dispersionless injections. In our simulation we vary the pulse speed with the radial distance from the Earth to match the surprisingly low propa- gation velocities that have been measured inside geostationary orbit. We show that a deccelerating electromagnetic field configuration is able to produce dispersionless in- jections inside of geostationary orbit. We have reproduced a particular event (February 12, 1991) as seen by two spacecraft (CRRES and LANL 1990-095) when they were around local midnight and at different radial distances. We explain the energization of electrons during this interaction by means of betatron acceleration and we show that under our model electrons are transported inside geosynchronous orbit from more than a few RE tailward.

  8. Numerical simulations of capillary barrier field tests

    Energy Technology Data Exchange (ETDEWEB)

    Morris, C.E. [Univ. of Wollongong (Australia); Stormont, J.C. [Univ. of New Mexico, Albuquerque, NM (United States)

    1997-12-31

    Numerical simulations of two capillary barrier systems tested in the field were conducted to determine if an unsaturated flow model could accurately represent the observed results. The field data was collected from two 7-m long, 1.2-m thick capillary barriers built on a 10% grade that were being tested to investigate their ability to laterally divert water downslope. One system had a homogeneous fine layer, while the fine soil of the second barrier was layered to increase its ability to laterally divert infiltrating moisture. The barriers were subjected first to constant infiltration while minimizing evaporative losses and then were exposed to ambient conditions. The continuous infiltration period of the field tests for the two barrier systems was modelled to determine the ability of an existing code to accurately represent capillary barrier behavior embodied in these two designs. Differences between the field test and the model data were found, but in general the simulations appeared to adequately reproduce the response of the test systems. Accounting for moisture retention hysteresis in the layered system will potentially lead to more accurate modelling results and is likely to be important when developing reasonable predictions of capillary barrier behavior.

  9. Microbial succession and stimulation following a test well injection simulating CO2 leakage into shallow Newark Basin aquifers

    Science.gov (United States)

    Dueker, M.; Clauson, K.; Yang, Q.; Umemoto, K.; Seltzer, A. M.; Zakharova, N. V.; Matter, J. M.; Stute, M.; Takahashi, T.; Goldberg, D.; O'Mullan, G. D.

    2012-12-01

    Despite growing appreciation for the importance of microbes in altering geochemical reactions in the subsurface, the microbial response to geological carbon sequestration injections and the role of microbes in altering metal mobilization following leakage scenarios in shallow aquifers remain poorly constrained. A Newark Basin test well was utilized in field experiments to investigate patterns of microbial succession following injection of CO2 saturated water into isolated aquifer intervals. Additionally, laboratory mesocosm experiments, including microbially-active and inactive (autoclave sterilized) treatments, were used to constrain the microbial role in mineral dissolution, trace metal release, and gas production (e.g. hydrogen and methane). Hydrogen production was detected in both sterilized and unsterilized laboratory mesocosm treatments, indicating abiotic hydrogen production may occur following CO2 leakage, and methane production was detected in unsterilized, microbially active mesocosms. In field experiments, a decrease in pH following injection of CO2 saturated aquifer water was accompanied by mobilization of trace elements (e.g. Fe and Mn), the production of hydrogen gas, and increased bacterial cell concentrations. 16S ribosomal RNA clone libraries, from samples collected before and after the test well injection, were compared in an attempt to link variability in geochemistry to changes in aquifer microbiology. Significant changes in microbial composition, compared to background conditions, were found following the test well injection, including a decrease in Proteobacteria, and an increased presence of Firmicutes, Verrucomicrobia, Acidobacteria and other microbes associated with iron reducing and syntrophic metabolism. The concurrence of increased microbial cell concentration, and rapid microbial community succession, with increased concentrations of hydrogen gas suggests that abiotically produced hydrogen may serve as an ecologically-relevant energy

  10. Mechanical instability induced by water weakening in laboratory fluid injection tests

    Science.gov (United States)

    David, C.; Dautriat, J.; Sarout, J.; Delle Piane, C.; Menéndez, B.; Macault, R.; Bertauld, D.

    2015-06-01

    To assess water-weakening effects in reservoir rocks, previous experimental studies have focused on changes in the failure envelopes derived from mechanical tests conducted on rocks fully saturated either with water or with inert fluids. So far, little attention has been paid to the mechanical behavior during fluid injection under conditions similar to enhanced oil recovery operations. We studied the effect of fluid injection on the mechanical behavior of the weakly consolidated Sherwood sandstone in laboratory experiments. Our specimens were instrumented with 16 ultrasonic P wave transducers for both passive and active acoustic monitoring during loading and fluid injection to record the acoustic signature of fluid migration in the pore space and the development of damage. Calibration triaxial tests were conducted on three samples saturated with air, water, or oil. In a second series of experiments, water and inert oil were injected into samples critically loaded up to 80% or 70% of the dry or oil-saturated compressive strength, respectively, to assess the impact of fluid migration on mechanical strength and elastic properties. The fluids were injected with a low back pressure to minimize effective stress variations during injection. Our observations show that creep takes place with a much higher strain rate for water injection compared to oil injection. The most remarkable difference is that water injection in both dry and oil-saturated samples triggers mechanical instability (macroscopic failure) within half an hour whereas oil injection does not after several hours. The analysis of X-ray computed tomography images of postmortem samples revealed that the mechanical instability was probably linked to loss of cohesion in the water-invaded region.

  11. Field testing driver night vision devices

    NARCIS (Netherlands)

    Kooi, F.L.; Kolletzki, D.

    2007-01-01

    This paper summarizes the available methodologies to field test driver night vision devices ranging from vehicle mounted camera’s to head-mounted NVG’s. As in flight trials, a formidable challenge is to collect meaningful performance measures. Night vision systems for land and air systems show many

  12. Trip Report-Produced-Water Field Testing

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, Enid J. [Los Alamos National Laboratory

    2012-05-25

    Los Alamos National Laboratory (LANL) conducted field testing of a produced-water pretreatment apparatus with assistance from faculty at the Texas A&M University (TAMU) protein separation sciences laboratory located on the TAMU main campus. The following report details all of the logistics surrounding the testing. The purpose of the test was to use a new, commercially-available filter media housing containing modified zeolite (surfactant-modified zeolite or SMZ) porous medium for use in pretreatment of oil and gas produced water (PW) and frac-flowback waters. The SMZ was tested previously in October, 2010 in a lab-constructed configuration ('old multicolumn system'), and performed well for removal of benzene, toluene, ethylbenzene, and xylenes (BTEX) from PW. However, a less-expensive, modular configuration is needed for field use. A modular system will allow the field operator to add or subtract SMZ filters as needed to accommodate site specific conditions, and to swap out used filters easily in a multi-unit system. This test demonstrated the use of a commercial filter housing with a simple flow modification and packed with SMZ for removing BTEX from a PW source in College Station, Texas. The system will be tested in June 2012 at a field site in Pennsylvania for treating frac-flowback waters. The goals of this test are: (1) to determine sorption efficiency of BTEX in the new configuration; and (2) to observe the range of flow rates, backpressures, and total volume treated at a given flow rate.

  13. Evaluation of Sulfide Control by Air-Injection in Sewer Force Mains: Field and Laboratory Study

    Directory of Open Access Journals (Sweden)

    Juan T. García

    2017-03-01

    Full Text Available Chemical and biological processes consume dissolved oxygen (DO in urban wastewater during transportation along sewer systems. Anaerobic conditions (DO < 0.2 mg/L are easily reached, leading to sulfide (S2− generation. Release of free sulfide, hydrogen sulfide gas (H2S, from the liquid to the gaseous phase, causes odor, corrosion of pipes and supposes a risk for health of people working in sewers. These issues get worse in force mains, due to inability to take oxygen from the gaseous phase of pipe. Air injection is a suggested practice to control H2S emission in force mains. That technique aims to keep aerobic conditions in wastewater in order to avoid sulfide generation and favor a decrease of Biochemical Organic Demand (BOD. However, several force mains with air injection are not achieving their goals due to a limited oxygen transfer. Field measurements of dissolved oxygen in urban wastewater are presented in an existing force main with air injection during the summer of 2014 in the southeast of Spain. A laboratory scale model is constructed to quantify two-phase flow conditions in pipe due to air injection for different incoming flows rates of water and air. Particularly, for the case of plug flow, also known as elongated bubble flow. Velocity field measurement of water phase in laboratory allows estimating turbulent diffusivity of oxygen in the water, Em, and inter-phase mass transfer coefficient KL(T. In the laboratory, flow and air depth, bubble length, water velocity field, pressure inside force main and water and airflow rates are determined experimentally. These variables are used to assess DO in water phase of force main by comparison with those obtained from field measurements. This work allows assessing air injection efficiency in wastewater, and, therefore, to predict DO in wastewater in force mains.

  14. Field evaluation of natural gas and dry sorbent injection for MWC emissions control

    Energy Technology Data Exchange (ETDEWEB)

    Wohadlo, S; Abbasi, H; Cygan, D [Institute of Gas Technology, Chicago, IL (United States)

    1993-10-01

    The Institute of Gas Technology (IGT), in cooperation with the Olmsted Waste-to-Energy Facility (OWEF) and with subcontracted engineering services from the Energy and Environmental Research Corporation (EER), has completed the detailed engineering and preparation of construction specifications for an Emissions Reduction Testing System (ERTS). The ERTS has been designed for retrofit to one of two 100-ton/day municipal waste combustors at the OWEF, located in Rochester, Minnesota. The purpose of the retrofit is to conduct a field evaluation of a combined natural gas and sorbent injection process (IGT`s METHANE de-TOX{sup SM}, IGT Patent No. 5,105,747) for reducing the emissions of oxides of nitrogen (NO{sub x}), hydrochloric acid (HCI), oxides of sulfur (SO{sub x}), carbon monoxide (CO), total hydrocarbons (THC), and chlorinated hydrocarbons (dioxin/furans). In addition, the design includes modifications for the control of heavy metals (HM). Development of the process should allow the waste-to-energy industry to meet the Federal New Source Performance Standards for these pollutants at significantly lower costs when compared to existing technology of Thermal deNO{sub x} combined with spray dryer scrubber/fabric filters. Additionally, the process should reduce boiler corrosion and increase both the thermal and power production efficiency of the facility.

  15. Field reversed configuration confinement enhancement through edge biasing and neutral beam injection.

    Science.gov (United States)

    Tuszewski, M; Smirnov, A; Thompson, M C; Korepanov, S; Akhmetov, T; Ivanov, A; Voskoboynikov, R; Schmitz, L; Barnes, D; Binderbauer, M W; Brown, R; Bui, D Q; Clary, R; Conroy, K D; Deng, B H; Dettrick, S A; Douglass, J D; Garate, E; Glass, F J; Gota, H; Guo, H Y; Gupta, D; Gupta, S; Kinley, J S; Knapp, K; Longman, A; Hollins, M; Li, X L; Luo, Y; Mendoza, R; Mok, Y; Necas, A; Primavera, S; Ruskov, E; Schroeder, J H; Sevier, L; Sibley, A; Song, Y; Sun, X; Trask, E; Van Drie, A D; Walters, J K; Wyman, M D

    2012-06-22

    Field reversed configurations (FRCs) with high confinement are obtained in the C-2 device by combining plasma gun edge biasing and neutral beam injection. The plasma gun creates an inward radial electric field that counters the usual FRC spin-up. The n = 2 rotational instability is stabilized without applying quadrupole magnetic fields. The FRCs are nearly axisymmetric, which enables fast ion confinement. The plasma gun also produces E × B shear in the FRC edge layer, which may explain the observed improved particle transport. The FRC confinement times are improved by factors 2 to 4, and the plasma lifetimes are extended from 1 to up to 4 ms.

  16. Fate of herbicides in a shallow aerobic aquifer: A continuous field injection experiment (Vejen,Denmark)

    DEFF Research Database (Denmark)

    Broholm, Mette; Rügge, K.; Tuxen, Nina

    2001-01-01

    A continuous, natural gradient, field injection experiment, involving six herbicides and a tracer, was performed in a shallow aerobic aquifer near Vejen, Denmark. Bentazone, ()-2-(4-chloro-2-methylphenoxy) propanoic acid (MCPP), dichlorprop, isoproturon, and the dichlobenil metabolite 2,6-dichlor......, with selected individual points for a longer period. The bromide plume followed a complex path through the monitoring network downgradient of the injection wells. The plume movement was controlled by spatially varied hydraulic conductivities of the sand deposit and influenced by asynchronous seasonal variation...... in groundwater potentials. An average flow velocity of 0.5 m/d was observed, as depicted by bromide. Bentazone, BAM, MCPP, and dichlorprop retardation was negligible, and only slight retardation of isoproturon was observed in the continuous injection experiment and a preceding pulse experiment. No degradation...

  17. Development of a Pediatric Visual Field Test.

    Science.gov (United States)

    Miranda, Marco A; Henson, David B; Fenerty, Cecilia; Biswas, Susmito; Aslam, Tariq

    2016-12-01

    We describe a pediatric visual field (VF) test based on a computer game where software and hardware combine to provide an enjoyable test experience. The test software consists of a platform-based computer game presented to the central VF. A storyline was created around the game as was a structure surrounding the computer monitor to enhance patients' experience. The patient is asked to help the central character collect magic coins (stimuli). To collect these coins a series of obstacles need to be overcome. The test was presented on a Sony PVM-2541A monitor calibrated from a central midpoint with a Minolta CS-100 photometer placed at 50 cm. Measurements were performed at 15 locations on the screen and the contrast calculated. Retinal sensitivity was determined by modulating stimulus in size. To test the feasibility of the novel approach 20 patients (4-16 years old) with no history of VF defects were recruited. For the 14 subjects completing the study, 31 ± 15 data points were collected on 1 eye of each patient. Mean background luminance and stimulus contrast were 9.9 ± 0.3 cd/m(2) and 27.9 ± 0.1 dB, respectively. Sensitivity values obtained were similar to an adult population but variability was considerably higher - 8.3 ± 9.0 dB. Preliminary data show the feasibility of a game-based VF test for pediatric use. Although the test was well accepted by the target population, test variability remained very high. Traditional VF tests are not well tolerated by children. This study describes a child-friendly approach to test visual fields in the targeted population.

  18. The development study on gas recycling injection in Yaha Gas Condensate Field, Tarim Basin, China

    Institute of Scientific and Technical Information of China (English)

    孙龙德; 宋文杰; 江同文

    2003-01-01

    The Yaha Gas Condensate Field is the largest one discovered in China so far. In order to enhance the condensate recovery, gas recycling at 50 MPa has been implemented in Yaha field. Such high-pressure injection is very rare throughout the world. This paper offers the description of the geology and fluid phase behavior of Yaha field. The reservoir productivity and injectivity equations, the optimal development and well patterns are presented. The follow-up investigation of the design implementation leads to the reasonable adjustment of the original development plan. The perforation principle and program of gas recycling for Yaha field are set up. The numerical simulation is used to predict the future production performance of gas recycling. Finally, a complete set of high-pressure gas recycling technology suite has been established. The field has come on-stream for one and a half year with condensate throughput of 590000 t in 2001, and fat profit returned. The success of high-pressure gas recycling in the Yaha field is of considerable importance from the theoretical and practical points of view and will considerably benefit the future development of other gas condensate fields in China.

  19. Scaleup tests and supporting research for the development of duct injection technology. Topical report No. 1, Literature review

    Energy Technology Data Exchange (ETDEWEB)

    Gooch, J.P.; Dismukes, E.B.; Dahlin, R.S.; Faulkner, M.G. [Southern Research Inst., Birmingham, AL (United States); Klett, M.G.; Buchanan, T.L.; Hunt, J.E. [Gilbert/Commonwealth, Inc., Reading, PA (United States)

    1989-05-01

    Gilbert Commonwealth, Southern Research Institute and the American Electric Power Service Corporation have embarked on a program to convert DOE`s Duct Injection Test Facility located at the Muskingum River Power Plant of Ohio Power Company to test alternate duct injection technologies. The technologies to be tested include slurry sorbent injection of hydrated lime using dual fluid nozzles, or a rotary atomizer and pneumatic injection of hydrated lime, with flue gas humidification before or after sorbent injection. The literature review and analysis contained in this report is a part of the preparatory effort for the test program.

  20. An anaerobic field injection experiment in a landfill leachate plume (Grindsted, Denmark)

    DEFF Research Database (Denmark)

    Albrechtsen, Hans-Jørgen; Bjerg, Poul Løgstrup; Ludvigsen, L.

    1999-01-01

    Redox conditions may be environmental factors which affect the fate of the xenobiotic organic compounds. Therefore the redox conditions were characterized in an anaerobic, leachate-contaminated aquifer 15–60 m downgradient from the Grindsted Landfill, Denmark, where an field injection experiment...... to the sediment samples. Samples were investigated with respect to groundwater chemistry, including hydrogen and volatile fatty acids (VFAs) and sediment geochemistry, and bioassays were performed. The groundwater chemistry, including redox sensitive species for a large number of samples, varied over time during...... the experimental period of 924 days owing to variations in the leachate from the landfill. However, no indication of change in the redox environment resulting from the field injection experiment or natural variation was observed in the individual sampling points. The methane, Fe(II), hydrogen, and VFA groundwater...

  1. Deep Borehole Field Test Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Ernest L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-09-30

    This report documents conceptual design development for the Deep Borehole Field Test (DBFT), including test packages (simulated waste packages, not containing waste) and a system for demonstrating emplacement and retrieval of those packages in the planned Field Test Borehole (FTB). For the DBFT to have demonstration value, it must be based on conceptualization of a deep borehole disposal (DBD) system. This document therefore identifies key options for a DBD system, describes an updated reference DBD concept, and derives a recommended concept for the DBFT demonstration. The objective of the DBFT is to confirm the safety and feasibility of the DBD concept for long-term isolation of radioactive waste. The conceptual design described in this report will demonstrate equipment and operations for safe waste handling and downhole emplacement of test packages, while contributing to an evaluation of the overall safety and practicality of the DBD concept. The DBFT also includes drilling and downhole characterization investigations that are described elsewhere (see Section 1). Importantly, no radioactive waste will be used in the DBFT, nor will the DBFT site be used for disposal of any type of waste. The foremost performance objective for conduct of the DBFT is to demonstrate safe operations in all aspects of the test.

  2. Field Test Kit for Gun Residue Detection

    Energy Technology Data Exchange (ETDEWEB)

    WALKER, PAMELA K.; RODACY, PHILIP J.

    2002-01-01

    One of the major needs of the law enforcement field is a product that quickly, accurately, and inexpensively identifies whether a person has recently fired a gun--even if the suspect has attempted to wash the traces of gunpowder off. The Field Test Kit for Gunshot Residue Identification based on Sandia National Laboratories technology works with a wide variety of handguns and other weaponry using gunpowder. There are several organic chemicals in small arms propellants such as nitrocellulose, nitroglycerine, dinitrotoluene, and nitrites left behind after the firing of a gun that result from the incomplete combustion of the gunpowder. Sandia has developed a colorimetric shooter identification kit for in situ detection of gunshot residue (GSR) from a suspect. The test kit is the first of its kind and is small, inexpensive, and easily transported by individual law enforcement personnel requiring minimal training for effective use. It will provide immediate information identifying gunshot residue.

  3. Ice slurry cooling development and field testing

    Energy Technology Data Exchange (ETDEWEB)

    Kasza, K.E. [Argonne National Lab., IL (United States); Hietala, J. [Northern States Power Co., Minneapolis, MN (United States); Wendland, R.D. [Electric Power Research Inst., Palo Alto, CA (United States); Collins, F. [USDOE, Washington, DC (United States)

    1992-07-01

    A new advanced cooling technology collaborative program is underway involving Argonne National Laboratory (ANL), Northern States Power (NSP) and the Electric Power Research Institute (EPRI). The program will conduct field tests of an ice slurry distributed load network cooling concept at a Northern States Power utility service center to further develop and prove the technology and to facilitate technology transfer to the private sector. The program will further develop at Argonne National Laboratory through laboratory research key components of hardware needed in the field testing and develop an engineering data base needed to support the implementation of the technology. This program will sharply focus and culminate research and development funded by both the US Department of Energy and the Electric Power Research Institute on advanced cooling and load management technology over the last several years.

  4. Ice slurry cooling development and field testing

    Energy Technology Data Exchange (ETDEWEB)

    Kasza, K.E. (Argonne National Lab., IL (United States)); Hietala, J. (Northern States Power Co., Minneapolis, MN (United States)); Wendland, R.D. (Electric Power Research Inst., Palo Alto, CA (United States)); Collins, F. (USDOE, Washington, DC (United States))

    1992-01-01

    A new advanced cooling technology collaborative program is underway involving Argonne National Laboratory (ANL), Northern States Power (NSP) and the Electric Power Research Institute (EPRI). The program will conduct field tests of an ice slurry distributed load network cooling concept at a Northern States Power utility service center to further develop and prove the technology and to facilitate technology transfer to the private sector. The program will further develop at Argonne National Laboratory through laboratory research key components of hardware needed in the field testing and develop an engineering data base needed to support the implementation of the technology. This program will sharply focus and culminate research and development funded by both the US Department of Energy and the Electric Power Research Institute on advanced cooling and load management technology over the last several years.

  5. Combustion Safety Simplified Test Protocol Field Study

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L [Gas Technology Inst., Des Plaines, IL (United States); Cautley, D. [Gas Technology Inst., Des Plaines, IL (United States); Bohac, D. [Gas Technology Inst., Des Plaines, IL (United States); Francisco, P. [Gas Technology Inst., Des Plaines, IL (United States); Shen, L. [Gas Technology Inst., Des Plaines, IL (United States); Gloss, S. [Gas Technology Inst., Des Plaines, IL (United States)

    2015-11-05

    "9Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.

  6. The efficacy of an ivermectin/closantel injection against experimentally induced infections and field infections with gastrointestinal nematodes and liver fluke in cattle

    NARCIS (Netherlands)

    Borgsteede, F.H.M.; Taylor, S.; Gaasenbeek, C.P.H.; Couper, A.; Cromie, L.

    2008-01-01

    Three studies were performed to test the efficacy of an ivermectin/closantel injection (200 ¿g/kg¿1 ivermectin and 5 mg/kg¿1 closantel) in cattle. Two were experimentally induced infections of Ostertagia ostertagi, Cooperia oncophora and Fasciola hepatica in calves, and the third had natural field

  7. The efficacy of an ivermectin/closantel injection against experimentally induced infections and field infections with gastrointestinal nematodes and liver fluke in cattle

    NARCIS (Netherlands)

    Borgsteede, F.H.M.; Taylor, S.; Gaasenbeek, C.P.H.; Couper, A.; Cromie, L.

    2008-01-01

    Three studies were performed to test the efficacy of an ivermectin/closantel injection (200 ¿g/kg¿1 ivermectin and 5 mg/kg¿1 closantel) in cattle. Two were experimentally induced infections of Ostertagia ostertagi, Cooperia oncophora and Fasciola hepatica in calves, and the third had natural field i

  8. Optimization of brain MRA withcontrast injection in 1.5 T field

    Directory of Open Access Journals (Sweden)

    H. Qenaati

    2006-01-01

    Full Text Available Background and purpose: Selection of suitable parameters for brain MRA requires accurate measures, because the image quality depends on the location of arteries, veins and also the velocity differences of blood, taking into account the low blood flow in small veins and arteries, use of paramagnetic contrast media is recommended. Hence, in present study, we investigated the imaging optimization of brain vessels using contrast media in 1.5 T field.Materials and Methods: For image optimization blood T1 was estimated after the injection of 0.1mmol/kg of Gd-DTPA and the relative blood signals were measured at T1=300, 600, 900 and 1200ms using TR=20ms and TE=7ms parameters. Ernest angle and relative signal increased as the T1 decreased. MRA was obtained in three groups, each including five volunteer patients using parameters TR=20ms, TE=7ms and flip angle 10, 20 & 30 degrees in two series without and during contrast injection.Signals of carotid, M.C.A and thorcolar herofili and SD in air were measured and it was shown that in 20 degrees flip angle, C/N was maximum.At the last stage, three series of MRA, without, during c.i and 15 minutes after c.i where obtained in 20 volunteer patients using parameters TR=20ms, TE=7ms and flip angle 20 degrees and calculated C/N .Results: After statistical analysis the highest C/N was observed during c.i MRA. Paired t-student test was performed to compare the differences between the C/N ratios. For clinical purposes one vein and two arterles were graded in 5 definite levels.Conclusion: Results indicated an important effect of paramagnetic contrast media on better observing of small arteries and vein. The best quality was taken during c.i, but in some arteries contrast media did not improve the quality of MRA.

  9. Deep Borehole Field Test Laboratory and Borehole Testing Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlman, Kristopher L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brady, Patrick V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); MacKinnon, Robert J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Heath, Jason E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Herrick, Courtney G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jensen, Richard P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gardner, W. Payton [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sevougian, S. David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bryan, Charles R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jang, Je-Hun [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stein, Emily R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bauer, Stephen J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Daley, Tom [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Freifeld, Barry M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Birkholzer, Jens [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Spane, Frank A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-19

    Deep Borehole Disposal (DBD) of high-level radioactive wastes has been considered an option for geological isolation for many years (Hess et al. 1957). Recent advances in drilling technology have decreased costs and increased reliability for large-diameter (i.e., ≥50 cm [19.7”]) boreholes to depths of several kilometers (Beswick 2008; Beswick et al. 2014). These advances have therefore also increased the feasibility of the DBD concept (Brady et al. 2009; Cornwall 2015), and the current field test design will demonstrate the DBD concept and these advances. The US Department of Energy (DOE) Strategy for the Management and Disposal of Used Nuclear Fuel and High-Level Radioactive Waste (DOE 2013) specifically recommended developing a research and development plan for DBD. DOE sought input or expression of interest from States, local communities, individuals, private groups, academia, or any other stakeholders willing to host a Deep Borehole Field Test (DBFT). The DBFT includes drilling two boreholes nominally 200m [656’] apart to approximately 5 km [16,400’] total depth, in a region where crystalline basement is expected to begin at less than 2 km depth [6,560’]. The characterization borehole (CB) is the smaller-diameter borehole (i.e., 21.6 cm [8.5”] diameter at total depth), and will be drilled first. The geologic, hydrogeologic, geochemical, geomechanical and thermal testing will take place in the CB. The field test borehole (FTB) is the larger-diameter borehole (i.e., 43.2 cm [17”] diameter at total depth). Surface handling and borehole emplacement of test package will be demonstrated using the FTB to evaluate engineering feasibility and safety of disposal operations (SNL 2016).

  10. Detection of fiber damage in a graphite epoxy composite using current injection and magnetic field mapping

    Science.gov (United States)

    Blalock, T. N.; Yost, W. T.

    1986-01-01

    A novel NDE technique is reported for detecting fiber disruptions in graphite-epoxy composites. The technique involves injecting electric current along the graphite fibers of a composite and measuring the resulting magnetic fields. The disruptions in current paths, which occur in areas of fiber damage, are detectable as perturbations in the magnetic field. The experimental setup, the measurements, and the magnetic images of experimental samples are presented. A resistive model has been developed to be used in the modeling of two-dimensional conductivity patterns in graphite composites. Diagrams of the setup and the circuitry are included.

  11. A new method of field MRTD test

    Science.gov (United States)

    Chen, Zhibin; Song, Yan; Liu, Xianhong; Xiao, Wenjian

    2014-09-01

    MRTD is an important indicator to measure the imaging performance of infrared camera. In the traditional laboratory test, blackbody is used as simulated heat source which is not only expensive and bulky but also difficult to meet field testing requirements of online automatic infrared camera MRTD. To solve this problem, this paper introduces a new detection device for MRTD, which uses LED as a simulation heat source and branded plated zinc sulfide glass carved four-bar target as a simulation target. By using high temperature adaptability cassegrain collimation system, the target is simulated to be distance-infinite so that it can be observed by the human eyes to complete the subjective test, or collected to complete objective measurement by image processing. This method will use LED to replace blackbody. The color temperature of LED is calibrated by thermal imager, thereby, the relation curve between the LED temperature controlling current and the blackbody simulation temperature difference is established, accurately achieved the temperature control of the infrared target. Experimental results show that the accuracy of the device in field testing of thermal imager MRTD can be limited within 0.1K, which greatly reduces the cost to meet the project requirements with a wide application value.

  12. Intermediate Scale Laboratory Testing to Understand Mechanisms of Capillary and Dissolution Trapping during Injection and Post-Injection of CO2 in Heterogeneous Geological Formations

    Energy Technology Data Exchange (ETDEWEB)

    Illangasekare, Tissa [Colorado School of Mines, Golden, CO (United States); Trevisan, Luca [Colorado School of Mines, Golden, CO (United States); Agartan, Elif [Colorado School of Mines, Golden, CO (United States); Mori, Hiroko [Colorado School of Mines, Golden, CO (United States); Vargas-Johnson, Javier [Colorado School of Mines, Golden, CO (United States); Gonzalez-Nicolas, Ana [Colorado School of Mines, Golden, CO (United States); Cihan, Abdullah [Colorado School of Mines, Golden, CO (United States); Birkholzer, Jens [Colorado School of Mines, Golden, CO (United States); Zhou, Quanlin [Colorado School of Mines, Golden, CO (United States)

    2015-03-31

    Carbon Capture and Storage (CCS) represents a technology aimed to reduce atmospheric loading of CO2 from power plants and heavy industries by injecting it into deep geological formations, such as saline aquifers. A number of trapping mechanisms contribute to effective and secure storage of the injected CO2 in supercritical fluid phase (scCO2) in the formation over the long term. The primary trapping mechanisms are structural, residual, dissolution and mineralization. Knowledge gaps exist on how the heterogeneity of the formation manifested at all scales from the pore to the site scales affects trapping and parameterization of contributing mechanisms in models. An experimental and modeling study was conducted to fill these knowledge gaps. Experimental investigation of fundamental processes and mechanisms in field settings is not possible as it is not feasible to fully characterize the geologic heterogeneity at all relevant scales and gathering data on migration, trapping and dissolution of scCO2. Laboratory experiments using scCO2 under ambient conditions are also not feasible as it is technically challenging and cost prohibitive to develop large, two- or three-dimensional test systems with controlled high pressures to keep the scCO2 as a liquid. Hence, an innovative approach that used surrogate fluids in place of scCO2 and formation brine in multi-scale, synthetic aquifers test systems ranging in scales from centimeter to meter scale developed used. New modeling algorithms were developed to capture the processes controlled by the formation heterogeneity, and they were tested using the data from the laboratory test systems. The results and findings are expected to contribute toward better conceptual models, future improvements to DOE numerical codes, more accurate assessment of storage capacities, and optimized placement strategies. This report presents the experimental and modeling methods

  13. Image-guided spinal injection procedures in open high-field MRI with vertical field orientation: feasibility and technical features

    Energy Technology Data Exchange (ETDEWEB)

    Streitparth, F.; Walter, T.; Wonneberger, U.; Wagner, M.; Hermann, K.G.; Hamm, B.; Teichgraeber, U. [Charite, Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin (Germany); Chopra, S. [Charite-Universitaetsmedizin Berlin, Campus Virchow Klinikum, Department of General, Visceral, and Transplantation Surgery, Berlin (Germany); Wichlas, F. [Charite-Universitaetsmedizin Berlin, Campus Virchow Klinikum, Center for Musculoskeletal Surgery, Berlin (Germany)

    2010-02-15

    We prospectively evaluated the feasibility and technical features of MR-guided lumbosacral injection procedures in open high-field MRI at 1.0 T. In a CuSO{sub 4}.5H{sub 2}O phantom and five human cadaveric spines, fluoroscopy sequences (proton-density-weighted turbo spin-echo (PDw TSE), T1w TSE, T2w TSE; balanced steady-state free precession (bSSFP), T1w gradient echo (GE), T2w GE) were evaluated using two MRI-compatible 20-G Chiba-type needles. Artefacts were analysed by varying needle orientation to B{sub 0}, frequency-encoding direction and slice orientation. Image quality was described using the contrast-to-noise ratio (CNR). Subsequently, a total of 183 MR-guided nerve root (107), facet (53) and sacroiliac joint (23) injections were performed in 53 patients. In vitro, PDw TSE sequence yielded the best needle-tissue contrasts (CNR = 45, 18, 15, 9, and 8 for needle vs. fat, muscle, root, bone and sclerosis, respectively) and optimal artefact sizes (width and tip shift less than 5 mm). In vivo, PDw TSE sequence was sufficient in all cases. The acquisition time of 2 s facilitated near-real-time MRI guidance. Drug delivery was technically successful in 100% (107/107), 87% (46/53) and 87% (20/23) of nerve root, facet and sacroiliac joint injections, respectively. No major complications occurred. The mean procedure time was 29 min (range 19-67 min). MR-guided spinal injections in open high-field MRI are feasible and accurate using fast TSE sequence designs. (orig.)

  14. Performance Test of CCTV in a Test Field

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyung Min [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2011-10-15

    On April 12-13, 2010, US President Obama hosted a Nuclear Security Summit in Washington, DC, to enhance international cooperation to prevent nuclear terrorism, an issue which he has identified as the most immediate and extreme threat to global security. The Summit focused on the security of nuclear materials, nonproliferation, disarmament, and peaceful nuclear energy. At the summit, the Republic of Korea was chosen as the host of the next Summit in 2012. This series of events reflects the growing global interest on 'Nuclear Security' and as the host country of the next Nuclear Summit it is the time for Korea to strengthen the physical protection regime for nuclear facilities as a first step of securing its nuclear security capability. KINAC has been operating Test field as a mean of preparing solid backup data for reviewing and revising DBT (Design Basis Threat) and to test components of the conventional physical protection system. CCTV is a key component which is used worldwide for the assessment measure of alarms. In terms of performance test of CCTV, there are several elements such as image quality, coverage and mechanical features (speed of zoom-in-out, capture, angle shift etc.). Speaking of image quality acquired by the CCTV, the quality is subject to resolution, monitor specification, camera housing, camera mounting and lightening. Thus it is clear that performance tests on image quality should consider those factors and vary the factors respectively in order to verify the influence and the interaction among those. Nevertheless due to the restrictions of the current Test field, this paper focuses on the image quality through resolution test under the various lightening conditions

  15. Possible control scenario of radial electric field by loss-cone-particle injection into helical device

    Energy Technology Data Exchange (ETDEWEB)

    Motojima, Osamu; Shishkin, A.A.; Inagaki, Shigeru; Watanabe, Kiyomasa [National Inst. for Fusion Science, Toki, Gifu (Japan)

    1999-08-01

    The possibility of controlling the radial electric field of toroidal plasmas by injecting high energy electrons along the reversible loss cone orbit of the helical magnetic traps is investigated. It is well known that the radial electric field plays an important role in the confinement improvement scenario especially in the low collisional regime under the physics picture of neoclassical theory. For this purpose, it is made clear that the most suitable particles are transit particles, which show a transition from helically trapped orbits to blocked ones. It is also found that a parallel AC electric field launched from outside assists this transition and makes it possible for particles to penetrate deeply into the plasma. In addition we clarify that the viscosity of the plasma coupled with the helical field configuration provide a bifurcation of plasma states and its stable solution results in confinement improvement. (author)

  16. Modeling Single Well Injection-Withdrawal (SWIW) Tests for Characterization of Complex Fracture-Matrix Systems

    Energy Technology Data Exchange (ETDEWEB)

    Cotte, F.P.; Doughty, C.; Birkholzer, J.

    2010-11-01

    The ability to reliably predict flow and transport in fractured porous rock is an essential condition for performance evaluation of geologic (underground) nuclear waste repositories. In this report, a suite of programs (TRIPOLY code) for calculating and analyzing flow and transport in two-dimensional fracture-matrix systems is used to model single-well injection-withdrawal (SWIW) tracer tests. The SWIW test, a tracer test using one well, is proposed as a useful means of collecting data for site characterization, as well as estimating parameters relevant to tracer diffusion and sorption. After some specific code adaptations, we numerically generated a complex fracture-matrix system for computation of steady-state flow and tracer advection and dispersion in the fracture network, along with solute exchange processes between the fractures and the porous matrix. We then conducted simulations for a hypothetical but workable SWIW test design and completed parameter sensitivity studies on three physical parameters of the rock matrix - namely porosity, diffusion coefficient, and retardation coefficient - in order to investigate their impact on the fracture-matrix solute exchange process. Hydraulic fracturing, or hydrofracking, is also modeled in this study, in two different ways: (1) by increasing the hydraulic aperture for flow in existing fractures and (2) by adding a new set of fractures to the field. The results of all these different tests are analyzed by studying the population of matrix blocks, the tracer spatial distribution, and the breakthrough curves (BTCs) obtained, while performing mass-balance checks and being careful to avoid some numerical mistakes that could occur. This study clearly demonstrates the importance of matrix effects in the solute transport process, with the sensitivity studies illustrating the increased importance of the matrix in providing a retardation mechanism for radionuclides as matrix porosity, diffusion coefficient, or retardation

  17. Carbon Dioxide Flooding Technology Research and Field Test in Liuzan North Block

    Science.gov (United States)

    Zhang, Hanshi; Luo, Pingya; Sun, Lei; Fu, Zhijun

    2014-12-01

    The fault roots of Liuzan north block in Jidong oilfield of China have been long-term explored by solution gas drive. Recently, oil production declined rapidly because of shortage of formation energy and needing high water injection pressure. Carbon dioxide injection pressure is found to be generally low, and CO2 has good solubility in crude oil to supply formation energy and achieve high oil recovery efficiency. In this work, a pilot program of CO2 EOR technology was carried out. The slim tube test results showed that the minimal miscible pressure of Liuzan north block was 28.28 MPa. The injection parameters were optimized by numerical simulation method: the injection method was continuous, the slug size was 0.2 HCPV and the EOR efficiency was 7.23%. After two months of gas injection field test, the formation pressure of two gas injectors just increased by 14.02 MPa and 2.98 MPa, respectively, indicating that carbon dioxide could supply the formation energy effectively. 16 months after gas injection, the CO2 injection amount was 14640 t, and the oil increment was 16424 t. The present work demonstrates the potential applicability of CO2 flooding technology from high water injection reservoirs.

  18. B and Li isotopes as intrinsic tracers for injection tests in aquifer storage and recovery systems

    Energy Technology Data Exchange (ETDEWEB)

    Kloppmann, Wolfram, E-mail: w.kloppmann@brgm.fr [BRGM, French Geological Survey, 3 Av. Claude Guillemin B.P. 6009, F-45000 Orleans (France); Chikurel, Haim [Mekorot National Water Company, Tel Aviv (Israel); Picot, Geraldine [BRGM, French Geological Survey, 3 Av. Claude Guillemin B.P. 6009, F-45000 Orleans (France); Guttman, Joseph [Mekorot National Water Company, Tel Aviv (Israel); Pettenati, Marie [BRGM, French Geological Survey, 3 Av. Claude Guillemin B.P. 6009, F-45000 Orleans (France); Aharoni, Avi [Mekorot National Water Company, Tel Aviv (Israel); Guerrot, Catherine; Millot, Romain; Gaus, Irina [BRGM, French Geological Survey, 3 Av. Claude Guillemin B.P. 6009, F-45000 Orleans (France); Wintgens, Thomas [Rheinisch Westfaelische Technische Hochschule, RWTH, Aachen (Germany)

    2009-07-15

    Boron and Li isotopes have been tested as environmental tracers of treated sewage injected into a sandy aquifer (Shafdan reclamation project, Israel). During a 38 days injection test in a newly dug injection well, a conservative artificial tracer (Br{sup -}) was monitored together with {delta}{sup 11}B and {delta}{sup 7}Li in the injectate, in the unsaturated soil zone (porous cup) and an observation well in the aquifer. In spite of B and Li concentrations in the injectate close to background values, significant shifts of the isotope signatures could be observed over the duration of the injection test. Boron isotope ratios show a breakthrough curve delayed with respect to Br{sup -} breakthrough due to some reversible sorption on the aquifer material. No isotope fractionation was observed in the unsaturated or the saturated zone so that B isotopes can be considered as conservative in the investigated part of the aquifer system. Lithium isotopes are strongly fractionated, probably due to sorption processes. Lithium concentrations point to a Li sink in the system, {delta}{sup 7}Li values vary strongly with a tendency of {sup 7}Li depletion in the liquid phase over the duration of the experiment. This is opposite to the expected preferential sorption of {sup 6}Li onto clay minerals. Boron isotopes reveals a valuable tracer of artificial recharge of freshwaters derived from treated sewage, both for short term tracer tests and for long-term monitoring of artificial recharge, even if in aquifers with higher clay contents, sorption-linked isotope fractionation cannot be excluded. More data are needed on Li isotope fractionation in natural groundwater systems to assess the potential of this tracer as monitoring tool.

  19. Preliminary Results of Field Emission Cathode Tests

    Science.gov (United States)

    Sovey, James S.; Kovaleski, Scott D.

    2001-01-01

    Preliminary screening tests of field emission cathodes such as chemical vapor deposited (CVD) diamond, textured pyrolytic graphite, and textured copper were conducted at background pressures typical of electric thruster test facilities to assess cathode performance and stability. Very low power electric thrusters which provide tens to hundreds micronewtons of thrust may need field emission neutralizers that have a capability of tens to hundreds of microamperes. From current voltage characteristics, it was found that the CVD diamond and textured metals cathodes clearly satisfied the Fowler-Nordheim emission relation. The CVD diamond and a textured copper cathode had average current densities of 270 and 380 mA/sq cm, respectively, at the beginning-of-life. After a few hours of operation the cathode emission currents degraded by 40 to 75% at background pressures in the 10(exp -5) Pa to 10(exp -4) Pa range. The textured pyrolytic graphite had a modest current density at beginning-of-life of 84 mA/sq cm, but this cathode was the most stable of all. Extended testing of the most promising cathodes is warranted to determine if current degradation is a burn-in effect or whether it is a long-term degradation process. Preliminary experiments with ferroelectric emission cathodes, which are ceramics with spontaneous electric polarization, were conducted. Peak current densities of 30 to 120 mA/sq cm were obtained for pulse durations of about 500 ns in the 10(exp -4) Pa pressure range.

  20. Parameters Relevant to Bubble Detachment when Gas-injecting into Polymer Melt Flow Field

    Institute of Scientific and Technical Information of China (English)

    CHEN Zailiang; CAI Yebin; GUO Mingcheng; PENG Yucheng

    2005-01-01

    The bubble deformation processes were reported when gas was injected into polymer melt flow field in another paper, the experiments showed that the deformation was severely affected by the volume of the bubble, and in turn, for the different bubbles, several different deformation processes were presented during their movement along the flow channel. In addition, we could find that the magnitude of the bubble volume was dependent upon the pressure difference of the gas injection pressure and the melt pressure. In this paper, more experimental conditions were changed to investigate the parameters relevant to the detachment of bubbles from the injection nozzle. The experimental results show that the pressure difference, the melt flow velocity as well as the melt pressure were all critical for the parameters, such as the bubble detachment time, the maximum bubble diameters and the magnitude of the bubble volume. The morphology changes of bubble were very large when the flow field was abruptly changed, and the situations were more complicated.

  1. Gate field plate IGBT with trench accumulation layer for extreme injection enhancement

    Science.gov (United States)

    Xu, Xiaorui; Chen, Wanjun; Liu, Chao; Chen, Nan; Tao, Hong; Shi, Yijun; Ma, Yinchang; Zhou, Qi; Zhang, Bo

    2017-04-01

    A gate field plate IGBT (GFP-IGBT) with extreme injection enhancement is proposed and verified using TCAD simulations. The GFP-IGBT features a gate field plate (GFP) inserted into n-drift region directly and a tiny P-base region separated from the GFP. In the ON-state, the accumulation layer is formed near to not only the bottom but also the side of the trench, which enhances electron injection efficiency. And the tiny P-base region reduces the holes extracted by reverse-biased P-base/N-drift junction. Both the GFP and tiny P-base contribute to achieving extreme injection enhancement, leading to a low forward voltage drop. In the OFF-state, due to the low stored charges in N-buffer layer, GFP-IGBT shows a short current fall time, leading to a decrease of turn-off loss. The simulation results show that, compared with the conventional IGBT, the GFP-IGBT offers a forward voltage drop reduction of 25% or current fall time reduction of 89% (i.e. turn-off loss reduction of 53%), resulting in low power loss. The excellent device performance, coupled with a commercial IGBT-compatible fabrication process, makes the proposed GFP-IGBT a promising candidate for power switching applications.

  2. Advanced Utility Mercury-Sorbent Field-Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Ronald Landreth

    2007-12-31

    This report summarizes the work conducted from September 1, 2003 through December 31, 2007 on the project entitled Advanced Utility Mercury-Sorbent Field-Testing Program. The project covers the testing at the Detroit Edison St. Clair Plant and the Duke Power Cliffside and Buck Stations. The St. Clair Plant used a blend of subbituminous and bituminous coal and controlled the particulate emissions by means of a cold-side ESP. The Duke Power Stations used bituminous coals and controlled their particulate emissions by means of hot-side ESPs. The testing at the Detroit Edison St. Clair Plant demonstrated that mercury sorbents could be used to achieve high mercury removal rates with low injection rates at facilities that burn subbituminous coal. A mercury removal rate of 94% was achieved at an injection rate of 3 lb/MMacf over the thirty day long-term test. Prior to this test, it was believed that the mercury in flue gas of this type would be the most difficult to capture. This is not the case. The testing at the two Duke Power Stations proved that carbon- based mercury sorbents can be used to control the mercury emissions from boilers with hot-side ESPs. It was known that plain PACs did not have any mercury capacity at elevated temperatures but that brominated B-PAC did. The mercury removal rate varies with the operation but it appears that mercury removal rates equal to or greater than 50% are achievable in facilities equipped with hot-side ESPs. As part of the program, both sorbent injection equipment and sorbent production equipment was acquired and operated. This equipment performed very well during this program. In addition, mercury instruments were acquired for this program. These instruments worked well in the flue gas at the St. Clair Plant but not as well in the flue gas at the Duke Power Stations. It is believed that the difference in the amount of oxidized mercury, more at Duke Power, was the difference in instrument performance. Much of the equipment was

  3. Hot electrons injection in carbon nanotubes under the influence of quasi-static ac-field

    Science.gov (United States)

    Amekpewu, M.; Mensah, S. Y.; Musah, R.; Mensah, N. G.; Abukari, S. S.; Dompreh, K. A.

    2016-07-01

    The theory of hot electrons injection in carbon nanotubes (CNTs) where both dc electric field (Ez), and a quasi-static ac field exist simultaneously (i.e. when the frequency ω of ac field is much less than the scattering frequency v (ω ≪ v or ωτ ≪ 1, v =τ-1) where τ is relaxation time) is studied. The investigation is done theoretically by solving semi-classical Boltzmann transport equation with and without the presence of the hot electrons source to derive the current densities. Plots of the normalized current density versus dc field (Ez) applied along the axis of the CNTs in the presence and absence of hot electrons reveal ohmic conductivity initially and finally negative differential conductivity (NDC) provided ωτ ≪ 1 (i.e. quasi- static case). With strong enough axial injection of the hot electrons, there is a switch from NDC to positive differential conductivity (PDC) about Ez ≥ 75 kV / cm and Ez ≥ 140 kV / cm for a zigzag CNT and an armchair CNT respectively. Thus, the most important tough problem for NDC region which is the space charge instabilities can be suppressed due to the switch from the NDC behaviour to the PDC behaviour predicting a potential generation of terahertz radiations whose applications are relevance in current-day technology, industry, and research.

  4. New Experiences With Steam Injection From The MÜhlacker Field Site

    Science.gov (United States)

    Theurer, T.; Koschitzky, H.-P.; Färber, A.

    A thermally enhanced remediation scheme employing steam injection has been used at a former hazardous waste disposal site near the City of Mühlacker, Germany, to remove chlorinated solvents. Finding SVE (soil vapour extraction) to be ineffective in the unsaturated soil zone, a pilot-scale project was initiated in 1999 to employ steam injection in the highly contaminated unsaturated low permeable zone 7-15 meters be- low ground surface, limited on top and bottom by very low permeable layers. After completion of the project in September 2001, approximately 2.8 tons of chlorinated hydrocarbons had been removed from the 2500 m3 target area. This project served as a pilot site in the State of Baden-Württemberg EPA (Landesanstalt für Umweltschutz, LfU) site cleanup program, which was funded through the State's "Kommunaler Alt- lastenfonds". Detailed evaluation of SVE technology had indicated that the low permeability in this soil served as a limiting factor for "cold" SVE. As a result, alternative technologies were considered and thermally enhanced SVE by steam injection was selected in 1998 to address the unsaturated zone contaminants. A 20-meter diameter, egg-shaped test- ing area was constructed at the site for pilot-scale demonstration of the steam injection process. The testing area comprised one central injection well surrounded by six ex- traction wells that could be used simultaneously for vapor and liquid extraction. Ten monitoring lances with a total of 100 temperature sensors measured subsurface tem- peratures through the soil horizon. Using a gas-fired 100 kW generator, steam was injected at a rate of up to 100 kg/hour and a pressure of up to 2.5 bars. After ten months of steam injection, nearly complete heating of the target zone had been achieved. of the 2800 kg of TCE removed, approximately 95% was extracted in the gaseous phase and the remaining part as solute in condensed water from the capillary barrier on bottom of the soil horizon. This condensed

  5. The influence of the injection molding on mechanical properties of EPDM rubber testing samples

    OpenAIRE

    Škrobák, Adam; STANĚK, Michal; Maňas, David; Ovsík, Martin; Šenkeřík, Vojtěch; Řezníček, Martin; Hýlova, Lenka

    2016-01-01

    The paper deals with the impact of the production process on mechanical properties (tensile strength and tear strength) of a standardized testing sample made of rubber compound based on ethylene propylene diene rubber produced by injection molding in comparison with a sample produced by classic preparation (cutting out a compression molded plate) according to the standard ISO 23529.

  6. Inactivation of Bacteria in Oil Field Injected Water by a Pulsed Plasma Discharge Process

    Science.gov (United States)

    Xin, Qing; Li, Zhongjian; Lei, Lecheng; Yang, Bin

    2016-09-01

    Pulsed plasma discharge was employed to inactivate bacteria in the injection water for an oil field. The effects of water conductivity and initial concentration of bacteria on elimination efficiency were investigated in the batch and continuous flow modes. It was demonstrated that Fe2+ contained in injection water could enhance the elimination efficiency greatly. The addition of reducing agent glutathione (GSH) indicated that active radicals generated by pulsed plasma discharges played an important role in the inactivation of bacteria. Moreover, it was found that the microbial inactivation process for both batch and continuous flow mode well fitted the model based on the Weibull's survival function. supported by Zhejiang Province Welfare Technology Applied Research Project of China (No. 2014C31137), National Natural Science Foundation of China (Nos. 21436007 and U1462201), and the Fundamental Research Funds for the Central Universities of China (No. 2015QNA4032)

  7. Changes in the chemistry of shallow groundwater related to the 2008 injection of CO2 at the ZERT Field Site, Bozeman, Montana

    Energy Technology Data Exchange (ETDEWEB)

    Kharaka, Y.K.; Thordsen, T.T.; Kakouros, E.; Ambats, G.; Herkelrath, W.N.; Birkholzer, J.T.; Apps, J.A.; Spycher, N.F.; Zheng, L.; Trautz, R.C.; Rauch, H.W.; Gullickson, K.; Beers, S.R.

    2009-09-01

    Approximately 300 kg/day of food-grade CO2 was injected through a perforated pipe placed horizontally 2-2.3 m deep during July 9-August 7, 2008 at the MSU-ZERT field test to evaluate atmospheric and near-surface monitoring and detection techniques applicable to the subsurface storage and potential leakage of CO2. As part of this multidisciplinary research project, 80 samples of water were collected from 10 shallow monitoring wells (1.5 or 3.0 m deep) installed 1-6 m from the injection pipe, at the southwestern end of the slotted section (zone VI), and from two distant monitoring wells. The samples were collected before, during and following CO2 injection. The main objective of study was to investigate changes in the concentrations of major, minor and trace inorganic and organic compounds during and following CO2 injection.

  8. 3X-100 blade field test.

    Energy Technology Data Exchange (ETDEWEB)

    Zayas, Jose R.; Johnson, Wesley D.

    2008-03-01

    In support of a Work-For-Other (WFO) agreement between the Wind Energy Technology Department at Sandia National Laboratories and 3TEX, one of the three Micon 65/13M wind turbines at the USDA Agriculture Research Service (ARS) center in Bushland, Texas, has been used to test a set of 9 meter wind turbine blades, manufactured by TPI composites using the 3TEX carbon material for the spar cap. Data collected from the test has been analyzed to evaluate both the aerodynamic performance and the structural response from the blades. The blades aerodynamic and structural performance, the meteorological inflow and the wind turbine structural response has been monitored with an array of 57 instruments: 15 to characterize the blades, 13 to characterize inflow, and 15 to characterize the time-varying state of the turbine. For the test, data was sampled at a rate of 40 Hz using the ATLAS II (Accurate GPS Time-Linked Data Acquisition System) data acquisition system. The system features a time-synchronized continuous data stream and telemetered data from the turbine rotor. This paper documents the instruments and infrastructure that have been developed to monitor these blades, turbines and inflow, as well as both modeling and field testing results.

  9. IN SITU FIELD TESTING OF PROCESSES

    Energy Technology Data Exchange (ETDEWEB)

    J.S.Y. YANG

    2004-11-08

    The purpose of this scientific analysis report is to update and document the data and subsequent analyses from ambient field-testing activities performed in underground drifts and surface-based boreholes through unsaturated zone (UZ) tuff rock units. In situ testing, monitoring, and associated laboratory studies are conducted to directly assess and evaluate the waste emplacement environment and the natural barriers to radionuclide transport at Yucca Mountain. This scientific analysis report supports and provides data to UZ flow and transport model reports, which in turn contribute to the Total System Performance Assessment (TSPA) of Yucca Mountain, an important document for the license application (LA). The objectives of ambient field-testing activities are described in Section 1.1. This report is the third revision (REV 03), which supercedes REV 02. The scientific analysis of data for inputs to model calibration and validation as documented in REV 02 were developed in accordance with the Technical Work Plan (TWP) ''Technical Work Plan for: Performance Assessment Unsaturated Zone'' (BSC 2004 [DIRS 167969]). This revision was developed in accordance with the ''Technical Work Plan for: Unsaturated Zone Flow Analysis and Model Report Integration'' (BSC 2004 [DIRS 169654], Section 1.2.4) for better integrated, consistent, transparent, traceable, and more complete documentation in this scientific analysis report and associated UZ flow and transport model reports. No additional testing or analyses were performed as part of this revision. The list of relevant acceptance criteria is provided by ''Technical Work Plan for: Unsaturated Zone Flow Analysis and Model Report Integration'' (BSC 2004 [DIRS 169654]), Table 3-1. Additional deviations from the TWP regarding the features, events, and processes (FEPs) list are discussed in Section 1.3. Documentation in this report includes descriptions of how, and under what

  10. Mechanical properties test and microstructure analysis of polyoxymethylene (POM) micro injection moulded standard parts

    DEFF Research Database (Denmark)

    Tosello, Guido; Lucchetta, Giovanni; Hansen, Hans Nørgaard;

    2009-01-01

    to factorial plans, in which the factors of interest were mould temperature, melt temperature and dimensional range of the specimen (i.e. macro and micro parts). Micro structure analysis was performed by means of plastography techniques and revealed that high mould and melt temperatures resulted on a thin skin......The tensile mechanical properties and the micro structure of micro injection moulded polyoxymethylene (POM) test parts were investigated in this paper. The effects of different injection moulding processing conditions on ultimate tensile stress and strain at break were analyzed. Additionally...

  11. Plasma heating, electric fields and plasma flow by electron beam ionospheric injection

    Science.gov (United States)

    Winckler, J. R.; Erickson, K. N.

    1990-01-01

    The electric fields and the floating potentials of a Plasma Diagnostics Payload (PDP) located near a powerful electron beam injected from a large sounding rocket into the auroral zone ionosphere have been studied. As the PDP drifted away from the beam laterally, it surveyed a region of hot plasma extending nearly to 60 m radius. Large polarization electric fields transverse to B were imbedded in this hot plasma, which displayed large ELF wave variations and also an average pattern which has led to a model of the plasma flow about the negative line potential of the beam resembling a hydrodynamic vortex in a uniform flow field. Most of the present results are derived from the ECHO 6 sounding rocket mission.

  12. Separate Layer Production and Water Injection Technology Developed in Daqing Oil Field

    Institute of Scientific and Technical Information of China (English)

    Liu He

    2004-01-01

    @@ Effects of separate layer production and water injection With the improvement of geological research and development degree, the requirements to water injection are also higher than ever before. The development of water injection technology in Daqing oilfield experienced the following four stages: (1) Commingled water injection, (2)concentric water injection, (3) eccentric water injection, and (4) integrated water injection.Through the above improvements, the development technology improved quickly.

  13. THE STUDY OF GAS MIGRATION IN CRYSTALLINE ROCK USING INJECTION TESTS

    Directory of Open Access Journals (Sweden)

    Jiří Svoboda

    2012-07-01

    Full Text Available The study of gas migration in crystalline rock using injection tests is being carried out in the frame of the FORGE (Fate of Repository Gases project. The Czech Technical University in Prague (CTU, Centre of Experimental Geotechnics (CEG is participating in WP4 which is focused on disturbed host rock formations with respect to radioactive waste deep repositories. A series of in-situ tests is being conducted at the Josef Underground Laboratory. The aim of the testing is to simulate and study phenomena that might lead to gas-driven radionuclide transport in fractured crystalline rock. The in-situ tests combine migration and large-scale gas injection measurements; gas injection tests are being employed for the study of gas transport. For the purposes of comparison of the behaviour of the rock mass with regard to air and water a series of water pressure tests are also being carried out. The quality of the rock mass is assessed using rock mass classification systems.

  14. A fast alternative to core plug tests for optimising injection water salinity for EOR

    DEFF Research Database (Denmark)

    Hassenkam, Tue; Andersson, Martin Peter; Hilner, Emelie Kristin Margareta

    2014-01-01

    the relationship between the wettability of pore surfaces and water salinity. We functionalise AFM tips with organic molecules and use them to represent tiny oil droplets of nonpolar or polar molecules and we use sand grains removed from core plugs to represent the pore walls in sandstone. We bring our "oil" close......Core tests have demonstrated that decreasing the salinity of injection water can increase oil recovery. Although recovery is enhanced by simply decreasing salt content, optimising injection water salinty would offer a clear economic advantage for several reasons. Too low salinity risks swelling...... of the clays which would lead to permanent reservoir damage but evidence of effectiveness at moderate salinity would offer the opportunity to dispose of produced water. The goal is to define boundary conditions so injection water salinity is high enough to prevent reservoir damage and low enough to induce...

  15. Solute transport characterization in karst aquifers by tracer injection tests for a sustainable water resource management

    Science.gov (United States)

    Morales, T.; Angulo, B.; Uriarte, J. A.; Olazar, M.; Arandes, J. M.; Antiguedad, I.

    2017-04-01

    Protection of water resources is a major challenge today, given that territory occupation and land use are continuously increasing. In the case of karst aquifers, its dynamic complexity requires the use of specific methodologies that allow establishing local and regional flow and transport patterns. This information is particularly necessary when springs and wells harnessed for water supply are concerned. In view of the present state of the art, this work shows a new approach based on the use of a LiCl based tracer injection test through a borehole for transport characterization from a local to a regional scale. Thus a long term tracer injection test was conducted in a particularly sensitive sector of the Egino karst massif (Basque Country, Spain). The initial displacement of tracer in the vicinity of the injection was monitored in a second borehole at a radial distance of 10.24 m. This first information, assessed by a radial divergent model, allows obtaining transport characteristic parameters in this immediate vicinity during injection. At a larger (regional) scale, the tracer reaches a highly transmissive network with mean traveling velocities to the main springs being from 4.3 to 13.7 m/h. The responses obtained, particularly clear in the main spring used for water supply, and the persistence of part of the tracer in the injection zone, pose reconsidering the need for their protection. Thus, although the test allows establishing the 24-h isochrone, which is the ceiling value in present European vulnerability approaches, the results obtained advise widening the zone to protect in order to guarantee water quality in the springs. Overall, this stimulus-response test allows furthering the knowledge on the dynamics of solute transport in karst aquifers and is a particularly useful tool in studies related to source vulnerability and protection in such a complex medium.

  16. Improvement of neutral beam injection heating efficiency with magnetic field well structures in a tokamak with a low magnetic field

    Science.gov (United States)

    Kim, S. K.; Na, D. H.; Lee, J. W.; Yoo, M. G.; Kim, H.-S.; Hwang, Y. S.; Hahm, T. S.; Na, Yong-Su

    2016-10-01

    Magnetic well structures are introduced as an effective means to reduce the prompt loss of fast ions, the so-called first orbit loss from neutral beam injection (NBI), which is beneficial to tokamaks with a low magnetic field strength such as small spherical torus devices. It is found by single-particle analysis that this additional field structure can modify the gradient of the magnetic field to reduce the shift of the guiding center trajectory of the fast ion. This result is verified by a numerical calculation of following the fast ion’s trajectory. We apply this concept to the Versatile Experiment Spherical Torus [1], where NBI is under design for the purpose of achieving high-performance plasma, to evaluate the effect of the magnetic well structure on NBI efficiency. A 1D NBI analysis code and the NUBEAM code are employed for detailed NBI calculations. The simulation results show that the orbit loss can be reduced by 70%-80%, thereby improving the beam efficiency twofold compared with the reference case without the well structure. The well-shaped magnetic field structure in the low-field side can significantly decrease orbit loss by broadening the non-orbit loss region and widening the range of the velocity direction, thus improving the heating efficiency. It is found that this magnetic well can also improve orbit loss during the slowing down process.

  17. Scaleup tests and supporting research for the development of duct injection technology

    Energy Technology Data Exchange (ETDEWEB)

    Felix, L.G.; Dismukes, E.B.; Gooch, J.P. (Southern Research Inst., Birmingham, AL (United States)); Klett, M.G.; Demian, A.G. (Gilbert/Commonwealth, Inc., Reading, PA (United States))

    1992-04-20

    This Topical Report No. 2 is an interim report on the Duct Injection Test Facility being operated for the Department of Energy at Beverly, Ohio. Either dry calcium hydroxide or an aqueous slurry of calcium hydroxide (prepared by slaking quicklime) is injected into a slipstream of flue gas to achieve partial removal of SO{sub 2} from a coal-burning power station. Water injected with the slurry or injected separately from the dry sorbents cools the flue gas and increases the water vapor content of the gas. The addition of water, either in the slurry or in a separate spray, makes the extent of reaction between the sorbent and the SO{sub 2} more complete; the presumption is that water is effective in the liquid state, when it is able to wet the sorbent particles physically, and not especially effective in the vapor state. An electrostatic precipitator collects the combination of suspended solids (fly ash from the boiler and sorbent from the duct injection process). All of the operations are being carried out on the scale of approximately 50,000 acfm of flue gas.

  18. Injection locking at zero field in two free layer spin-valves

    Science.gov (United States)

    Carpentieri, Mario; Moriyama, Takahiro; Azzerboni, Bruno; Finocchio, Giovanni

    2013-03-01

    This paper predicts the possibility to achieve synchronization (via injection locking to a microwave current) of spin-transfer torque oscillators based on hybrid spin-valves composed by two free layers and two perpendicular polarizers at zero bias field. The locking regions are attained for microwave frequency near 0.5f0, f0, and 2f0, where f0 is the input oscillator frequency. Those properties make this system promising for applications, such as high-speed frequency dividers and multipliers, and phase-locked-loop demodulators.

  19. FIELD TEST OF THE FLAME QUALITY INDICATOR

    Energy Technology Data Exchange (ETDEWEB)

    Rudin, Andrew M; Butcher, Thomas; Troost, Henry

    2003-02-04

    The flame quality indicator concept was developed at BNL specifically to monitor the brightness of the flame in a small oil burner and to provide a ''call for service'' notification when the brightness has changed from its setpoint, either high or low. In prior development work BNL has explored the response of this system to operational upsets such as excess air changes, fouled atomizer nozzles, poor fuel quality, etc. Insight Technologies, Inc. and Honeywell, Inc. have licensed this technology from the U.S. Department of Energy and have been cooperating to develop product offerings which meet industry needs with an optimal combination of function and price. Honeywell has recently completed the development of the Flame Quality Monitor (FQM or Honeywell QS7100F). This is a small module which connects via a serial cable to the burners primary operating control. Primary advantages of this approach are simplicity, cost, and ease of installation. Call-for-service conditions are output in the form of front panel indicator lights and contact closure which can trigger a range of external communication options. Under this project a field test was conducted of the FQM in cooperation with service organizations in Virginia, Pennsylvania, New Jersey, New York, and Connecticut. At total of 83 field sites were included. At each site the FQM was installed in parallel with another embodiment of this concept--the Insight AFQI. The AFQI incorporates a modem and provides the ability to provide detailed information on the trends in the flame quality over the course of the two year test period. The test site population was comprised of 79.5% boilers, 13.7% warm air furnaces, and 6.8% water heaters. Nearly all were of residential size--with firing rates ranging from 0.6 gallons of oil per hour to 1.25. During the course of the test program the monitoring equipment successfully identified problems including: plugged fuel lines, fouled nozzles, collapsed combustion

  20. In Situ Decommissioning Sensor Network, Meso-Scale Test Bed - Phase 3 Fluid Injection Test Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Serrato, M. G.

    2013-09-27

    located at the Florida International University Applied Research Center, Miami, FL (FIU-ARC). A follow-on fluid injection test was developed to detect fluid and ion migration in a cementitious material/grouted test cube using a limited number of existing embedded sensor systems. This In Situ Decommissioning Sensor Network, Meso-Scale Test Bed (ISDSN-MSTB) - Phase 3 Fluid Injection Test Summary Report summarizes the test implementation, acquired and processed data, and results from the activated embedded sensor systems used during the fluid injection test. The ISDSN-MSTB Phase 3 Fluid Injection Test was conducted from August 27 through September 6, 2013 at the FIU-ARC ISDSN-MSTB test cube. The fluid injection test activated a portion of the existing embedded sensor systems in the ISDSN-MSTB test cube: Electrical Resistivity Tomography-Thermocouple Sensor Arrays, Advance Tensiometer Sensors, and Fiber Loop Ringdown Optical Sensors. These embedded sensor systems were activated 15 months after initial placement. All sensor systems were remotely operated and data acquisition was completed through the established Sensor Remote Access System (SRAS) hosted on the DOE D&D Knowledge Management Information Tool (D&D DKM-IT) server. The ISDN Phase 3 Fluid Injection Test successfully demonstrated the feasibility of embedding sensor systems to assess moisture-fluid flow and resulting transport potential for contaminate mobility through a cementitious material/grout monolith. The ISDSN embedded sensor systems activated for the fluid injection test highlighted the robustness of the sensor systems and the importance of configuring systems in-depth (i.e., complementary sensors and measurements) to alleviate data acquisition gaps.

  1. Cooperative field test program for wind systems

    Energy Technology Data Exchange (ETDEWEB)

    Bollmeier, W.S. II; Dodge, D.M.

    1992-03-01

    The objectives of the Federal Wind Energy Program, managed by the US Department of Energy (DOE), are (1) to assist industry and utilities in achieving a multi-regional US market penetration of wind systems, and (2) to establish the United States as the world leader in the development of advanced wind turbine technology. In 1984, the program conducted a series of planning workshops with representatives from the wind energy industry to obtain input on the Five-Year Research Plan then being prepared by DOE. One specific suggestion that came out of these meetings was that the federal program should conduct cooperative research tests with industry to enhance the technology transfer process. It was also felt that the active involvement of industry in DOE-funded research would improve the state of the art of wind turbine technology. DOE established the Cooperative Field Test Program (CFTP) in response to that suggestion. This program was one of the first in DOE to feature joint industry-government research test teams working toward common objectives.

  2. Formation and sustainment of field reversed configuration (FRC) plasmas by spheromak merging and neutral beam injection

    Science.gov (United States)

    Yamada, Masaaki

    2016-03-01

    This paper briefly reviews a compact toroid reactor concept that addresses critical issues for forming, stabilizing and sustaining a field reversed configuration (FRC) with the use of plasma merging, plasma shaping, conducting shells, neutral beam injection (NBI). In this concept, an FRC plasma is generated by the merging of counter-helicity spheromaks produced by inductive discharges and sustained by the use of neutral beam injection (NBI). Plasma shaping, conducting shells, and the NBI would provide stabilization to global MHD modes. Although a specific FRC reactor design is outside the scope of the present paper, an example of a promising FRC reactor program is summarized based on the previously developed SPIRIT (Self-organized Plasmas by Induction, Reconnection and Injection Techniques) concept in order to connect this concept to the recently achieved the High Performance FRC plasmas obtained by Tri Alpha Energy [Binderbauer et al, Phys. Plasmas 22,056110, (2015)]. This paper includes a brief summary of the previous concept paper by M. Yamada et al, Plasma Fusion Res. 2, 004 (2007) and the recent experimental results from MRX.

  3. Evaluation of miscible and immiscible CO2 injection in one of the Iranian oil fields

    Directory of Open Access Journals (Sweden)

    Aref Hashemi Fath

    2014-09-01

    Full Text Available Carbon dioxide (CO2 flooding is one of the most important methods for enhanced oil recovery (EOR because it not only increases oil recovery efficiency but also causes a reduction of greenhouse gas emissions. It is a very complex system, involving phase behavior that could increase the recovery of oil by means of swelling, evaporation and decreasing viscosity of the oil. In this study, a reservoir modeling approach was used to evaluate immiscible and miscible CO2 flooding in a fractured oil field. To reduce simulation time, we grouped fluid components into 10 pseudo-components. The 3-parameter, Peng–Robinson Equation of State (EOS was used to match PVT experimental data by using the PVTi software. A one-dimensional slim-tube model was defined using ECLIPSE 300 software to determine the minimum miscibility pressure (MMP for injection of CO2. We used FloGrid software for making a reservoir static model and the reservoir model was calibrated using manual and assisted history matching methods. Then various scenarios of natural depletion, immiscible and miscible CO2 injection have been simulated by ECLIPSE 300 software and then the simulation results of scenarios have been compared. Investigation of simulation results shows that the oil recovery factor in miscible CO2 injection scenario is more than other methods.

  4. Gadodiamide injection for enhancement of MRI in the CNS. Applications, dose, field and time dependence

    Energy Technology Data Exchange (ETDEWEB)

    Aakeson, P.

    1996-10-01

    Gadodiamide injection was comparable to Gd-DTPA with regard to both safety and diagnostic efficiency in the central nervous system. The contrast effect of Gd contrast agents is higher at 1.5 T than at 0.3 T both in phantoms and patients with a maximum ratio (signal lesion/signal grey matter) more than 50% higher at 1.5 T. To achieve high contrast effect, heavily T1-weighted images are important. Prolonging the TR from 400 ms to 600 ms reduced the ratio by 15-45% depending on concentration. The effective time window for imaging of BBB (Blood-Brain Barrier) damage is between 2-5 and 25-30 minutes after injection and several scans can be performed without loss of enhancement. To provide maximum detectability of BBB damage in patients, higher doses of Gd contrast media should be useful, especially at low field strengths, as the doses used clinically today do not utilize the maximum contrast effect. High-dose (0.3 mmol/kg b.w.) contrast enhanced MRI (0.3 T) with Gadodiamide injection allowed detection of significantly more and smaller metastases (i.e. BBB damage) than standard dose (0.1 mmol/kg b.w.) High dose contrast-enhanced MRI (0.3 T) did not increase the diagnostic information for the evaluation of patients with failed back surgery syndrome compared to standard dose MRI. 55 refs, 9 figs, 10 tabs.

  5. Simulation of field injection experiments in heterogeneous unsaturated media using cokriging and artificial neural network

    Science.gov (United States)

    Ye, Ming; Khaleel, Raziuddin; Schaap, Marcel G.; Zhu, Jianting

    2007-07-01

    Simulations of moisture flow in heterogeneous soils are often hampered by lack of measurements of soil hydraulic parameters, making it necessary to rely on other sources of information. In this paper, we develop a methodology to integrate data that can be easily obtained (for example, initial moisture content, θi, bulk density, and soil texture) with data on soil hydraulic properties via cokriging and Artificial Neural Network (ANN)-based pedotransfer functions. The method is applied to generate heterogeneous soil hydraulic parameters at a field injection site in southeastern Washington State. Stratigraphy at the site consists of imperfectly stratified layers with irregular layer boundaries. Cokriging is first used to generate three-dimensional heterogeneous fields of bulk density and soil texture using an extensive data set of field-measured θi, which carry signature about site heterogeneity and stratigraphy. Soil texture and bulk density are subsequently input into an ANN-based site-specific pedotransfer function to generate three-dimensional heterogeneous soil hydraulic parameter fields. The stratigraphy at the site is well represented by the estimated pedotransfer variables and soil hydraulic parameters. The parameter estimates are then used to simulate a field injection experiment at the site. A relatively good agreement is obtained between the simulated and observed moisture contents. The spatial distribution pattern of observed moisture content as well as the southeastward moisture movement is captured well in the simulations. In contrast to earlier work using an effective parameter approach (Yeh et al., 2005), we are able to reproduce the observed splitting of the moisture plume in a coarse sand unit that is sandwiched between two fine-textured units. The simple method of combining cokriging and ANN for site characterization provides unbiased prediction of the observed moisture plume and is flexible so that additional measurements of various types can be

  6. Time Lapse Gravity and Seismic Monitoring of CO2 Injection at the West Hastings Field, Texas

    Science.gov (United States)

    Ferguson, J. F.; Richards, T.; Klopping, F.; MacQueen, J.; Hosseini, S. A.

    2015-12-01

    Time lapse or 4D gravity and seismic reflection surveys are being conducted at the West Hastings Field near Houston, Texas to monitor the progress of CO2 injection. This Department of Energy supported CO2 sequestration experiment is conducted in conjunction with a Denbury Onshore, LLC tertiary recovery project. The reservoir is at a depth of 1.8 km in the Oligocene Frio sands and has been produced since the 1930s. Goals are an accounting and mapping of the injected CO2 and to determine if migration occurs along intra-reservoir faults. An integrated interpretation of the geophysical surveys will be made together with well logs and engineering data. Gravity monitoring of water versus gas replacement has been very successful, but liquid phase CO2 monitoring is problematic due to the smaller density contrast with respect to oil and water. This reservoir has a small volume to depth ratio and hence only a small gravity difference signal is expected on the surface. New borehole gravity technology introduced by Micro-g-Lacoste can make gravity measurements at near reservoir depths with a much higher signal to noise ratio. This method has been successfully evaluated on a simulation of the Hastings project. Field operations have been conducted for repeated surface and borehole gravity surveys beginning in 2013. The surface survey of 95 stations covers an area of 3 by 5 km and 22 borehole gravity logs are run in the interval above the Frio formation. 4D seismic reflection surveys are being made at 6 month intervals on the surface and in 3 VSP wells. CO2 injection into the targeted portion of the reservoir only began in early 2015 and monitoring will continue into 2017. To date only the baseline reservoir conditions have been assessed. The overall success of the gravity monitoring will not be determined until 2017.

  7. Planning and Analysis of Fractured Rock Injection Tests in the Cerro Brillador Underground Laboratory, Northern Chile

    Science.gov (United States)

    Fairley, J. P., Jr.; Oyarzún L, R.; Villegas, G.

    2015-12-01

    Early theories of fluid migration in unsaturated fractured rock hypothesized that matrix suction would dominate flow up to the point of matrix saturation. However, experiments in underground laboratories such as the ESF (Yucca Mountain, NV) have demonstrated that liquid water can migrate significant distances through fractures in an unsaturated porous medium, suggesting limited interaction between fractures and unsaturated matrix blocks and potentially rapid transmission of recharge to the sat- urated zone. Determining the conditions under which this rapid recharge may take place is an important factor in understanding deep percolation processes in arid areas with thick unsaturated zones. As part of an on-going, Fondecyt-funded project (award 11150587) to study mountain block hydrological processes in arid regions, we are plan- ning a series of in-situ fracture flow injection tests in the Cerro Brillador/Mina Escuela, an underground laboratory and teaching facility belonging to the Universidad la Serena, Chile. Planning for the tests is based on an analytical model and curve-matching method, originally developed to evaluate data from injection tests at Yucca Mountain (Fairley, J.P., 2010, WRR 46:W08542), that uses a known rate of liquid injection to a fracture (for example, from a packed-off section of borehole) and the observed rate of seepage discharging from the fracture to estimate effective fracture aperture, matrix sorptivity, fracture/matrix flow partitioning, and the wetted fracture/matrix interac- tion area between the injection and recovery points. We briefly review the analytical approach and its application to test planning and analysis, and describe the proposed tests and their goals.

  8. Global simulations of magnetorotational turbulence III: influence of field configuration and mass injection

    CERN Document Server

    Parkin, E R

    2014-01-01

    The stresses produced by magnetorotational turbulence can provide effective angular momentum transport in accretion disks. However, questions remain about the ability of simulated disks to reproduce observationally inferred stress-to-gas-pressure ratios. In this paper we present a set of high resolution global magnetohydrodynamic disk simulations which are initialised with different field configurations: purely toroidal, vertical field lines, and nested poloidal loops. A mass source term is included which allows the total disk mass to equilibrate in simulations with long run times, and also enables the impact of rapid mass injection to be explored. Notably different levels of angular momentum transport are observed during the early-time transient disk evolution. However, given sufficient time to relax, the different models evolve to a statistically similar quasi-steady state with a stress-to-gas-pressure ratio, $\\alpha \\sim 0.032-0.036$. The indication from our results is that {\\it steady, isolated} disks may...

  9. On-ground testing of the role of adhesion in the LISA-Pathfinder test mass injection phase

    Science.gov (United States)

    Bortoluzzi, D.; Zanoni, C.; Conklin, J. W.

    2017-05-01

    Many space missions share the need to fly a free-falling body inside the spacecraft, as a reference for navigation and/or as a probe for the local gravitational field. When a mechanism is required to cage such an object during the launch phase, the need arises to release it to free-fall once the operational phase must be initiated in orbit. The criticality of this phase increases when the mechanical interfaces between the body and the mechanism are affected by adhesion and the actuation authority of the control system on the free-falling body is limited. Both conditions are realized in the LISA Pathfinder mission, which aims at injecting a gold-coated 2 kg cubic test mass into a nearly perfect geodesic trajectory to demonstrate the readiness of the developed technology for in-space gravity wave detection. The criticality of adhesion is widely recognized in space technology, because it can affect and jeopardize the functionality of mechanisms, when arising between moving parts. In the LISA Pathfinder case, metallic adhesion potentially plays a relevant role, mainly for two reasons. First, thanks to its properties (ductility, high surface energy) the gold coating on the proof mass easily produces cold weldings, especially in vacuum conditions. Second, the detachment of the proof mass from the releasing device occurs abruptly and a relevant influence of the separation velocity is expected on the strength of the welding. This can produce an excessive velocity of the proof mass at the retraction of the releasing device for the following capture and centring phase on behalf of the control system. A testing activity is performed to characterize the dynamic behaviour of the adhesive bonds between the proof mass and the releasing device, which can be used to predict their contribution on the residual velocity of the proof mass after in-flight release. The study of such a dynamic phenomenon sets some challenging requirements on the measurement technique, both on the

  10. Laboratory evaluation and field application of a water swellable polymer for fracture shutoff in injection wells

    Energy Technology Data Exchange (ETDEWEB)

    Creel, Prentice [Kinder Morgan, Houston, TX (United States); Vasquez, Julio; Eoff, Larry [Halliburton, Rio de Janeiro, RJ (Brazil)

    2008-07-01

    This paper presents the laboratory evaluation and field application of a water swelling polymer (WSP) that can be bullheaded to shut off fractures in injection wells. The WSP is capable of absorbing 30 to 400 times its own weight in water. The material was evaluated for its effectiveness in providing controllable swelling rates, shutting off the flow of water in synthetic cores with simulated fractures, and providing long-term stability in H{sub 2}S and CO{sub 2} environments. In addition, this paper presents the field implementation of this technology along with successful case histories in west Texas. The water swellable material is mixed on the fly, entering fissures and fracture systems as they swell without invading the matrix of the rock. The rate of absorption can be controlled based on the specified particle size ranging from 600-mesh size up to 14 mm and the type of carrier fluid. This WSP presents an innovative technology for fracture, fissure, and highly eroded out permeability shutoff to improve the sweep efficiency of water and gas injection. In addition, the WSP is resistant to acid contamination and CO{sub 2} and H{sub 2}S environments. To date, more than 200 jobs have been performed with this technology. (author)

  11. Field operational tests of Smartway in Japan

    Directory of Open Access Journals (Sweden)

    Fumihiko Kanazawa

    2010-07-01

    Full Text Available Efforts are underway in Japan to promote “Smartway” next-generation roadways, which provide a variety of services through the use of advanced ITS technologies. In recent years, the National Institute for Land and Infrastructure Management (NILIM, part of the Ministry of Land, Infrastructure, Transport and Tourism (MLIT, has conducted public–private joint research on next-generation road services using ITS technologies. Field operational tests (FOTs of services including forward obstacle information provision and merging assistance using 5.8 GHz dedicated short range communication (DSRC were conducted on the Tokyo Metropolitan Expressway through FY2007. In FY2008–2009, FOTs were conducted in three major metropolitan areas—Tokyo, Nagoya, and Keihanshin (Kyoto, Osaka, and Kobe—to promote future deployment nationwide. These included tests of information provision services to alert drivers to forward obstacles hidden beyond the crest of an incline and prevent excessive speed on sharp curves. This paper presents an overview of these FOTs conducted by NILIM in recent years and their results.

  12. Characterization of compact-toroid injection during formation, translation, and field penetration

    Science.gov (United States)

    Matsumoto, T.; Roche, T.; Allfrey, I.; Sekiguchi, J.; Asai, T.; Gota, H.; Cordero, M.; Garate, E.; Kinley, J.; Valentine, T.; Waggoner, W.; Binderbauer, M.; Tajima, T.

    2016-11-01

    We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ˜1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation, ejection/translation from the MCPG, and penetration into transverse magnetic fields.

  13. Characterization of compact-toroid injection during formation, translation, and field penetration

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, T., E-mail: cstd14003@g.nihon-u.ac.jp; Sekiguchi, J.; Asai, T. [Nihon University, Chiyoda-ku, Tokyo 101-8308 (Japan); Roche, T.; Allfrey, I.; Gota, H.; Cordero, M.; Garate, E.; Kinley, J.; Valentine, T.; Waggoner, W.; Binderbauer, M. [Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688 (United States); Tajima, T. [Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688 (United States); Department of Physics and Astronomy, University of California, Irvine, California 92697 (United States)

    2016-11-15

    We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ∼1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation, ejection/translation from the MCPG, and penetration into transverse magnetic fields.

  14. Experimental study of the dependence of beam current on injection magnetic field in 6.4 GHz ECR ion source

    Indian Academy of Sciences (India)

    G S Taki; P R Sarma; D K Chakraborty; R K Bhandari; P K Ray

    2006-09-01

    The ion current from an electron cyclotron resonance (ECR) heavy ion source depends on the confining axial and radial magnetic fields. Some efforts were made by earlier workers to investigate magnetic field scaling on the performance of the ECR source. In order to study the dependence of the ion current on the injection magnetic field in the 6.4 GHz ECR source, we have measured the current by varying the peak injection field and have inferred that the variation of the current is exponential up to our maximum design injection field of 7.5 kG. An attempt has been made to understand this exponential nature on the basis of ion confinement time.

  15. [Skin test: guide of post-marketed re-evaluation of clinical safety in traditional Chinese medicine injection].

    Science.gov (United States)

    Wei, Xu; Xie, Yanming; Wang, Yongyan

    2011-10-01

    Anaphylaxis is the most common adverse reaction caused by traditional Chinese medicine (TCM) injection, the most serious of which is type I, so post-marketed safety re-evaluation is necessary. Skin test can be used to screen type I allergy reaction, which is of great significance for TCM injection safe use. Skin test is not only able to find the population sensitization situation of TCM injection, but also is a way of understanding the mechanism of allergy reaction. TCM injection varieties that often occur type I anaphylaxis are applicable to skin test, and study population include healthy volunteers and patients whose disease is listed in the drug specification, intracutaneous test and prick test are the alternative method. The concentration of skin-test solution may influence the positive rate of skin test, penicillin skin-test solution preparation method can be used as the reference in TCM injection. Different doses of TCM injection skin-test solution,glucose injection and normal saline, histamine hydrochloride are comprised in comparison. Given the characteristics of type I allergy reaction,we should be pay close attention to skin test reaction in half an hour, and observation index need be designed based on post-marketed re-evaluation of clinical safety.

  16. National Combustion Code Validated Against Lean Direct Injection Flow Field Data

    Science.gov (United States)

    Iannetti, Anthony C.

    2003-01-01

    Most combustion processes have, in some way or another, a recirculating flow field. This recirculation stabilizes the reaction zone, or flame, but an unnecessarily large recirculation zone can result in high nitrogen oxide (NOx) values for combustion systems. The size of this recirculation zone is crucial to the performance of state-of-the-art, low-emissions hardware. If this is a large-scale combustion process, the flow field will probably be turbulent and, therefore, three-dimensional. This research dealt primarily with flow fields resulting from lean direct injection (LDI) concepts, as described in Research & Technology 2001. LDI is a concept that depends heavily on the design of the swirler. The LDI concept has the potential to reduce NOx values from 50 to 70 percent of current values, with good flame stability characteristics. It is cost effective and (hopefully) beneficial to do most of the design work for an LDI swirler using computer-aided design (CAD) and computer-aided engineering (CAE) tools. Computational fluid dynamics (CFD) codes are CAE tools that can calculate three-dimensional flows in complex geometries. However, CFD codes are only beginning to correctly calculate the flow fields for complex devices, and the related combustion models usually remove a large portion of the flow physics.

  17. Southeast Geyers Cooperative Tracer Evaluation and Testing Program for the Purpose of Estimating The Efficiency of Injection

    Energy Technology Data Exchange (ETDEWEB)

    J.L. (Bill) Smith

    2001-02-12

    The Southeast Geysers Cooperative Tracer Evaluation Program has been a joint project located in the SE part of the Geysers geothermal field, in Lake and Sonoma Counties, California. A new generation of environmentally benign vapor-phase tracers has been used to estimate the varying degrees to which injectate is being recovered following the significant increase of injected volumes within the Southeast Geysers.

  18. Top Zika Vaccine Candidate Moves Closer to Field Testing

    Science.gov (United States)

    ... https://medlineplus.gov/news/fullstory_161274.html Top Zika Vaccine Candidate Moves Closer to Field Testing DNA- ... MONDAY, Oct. 3, 2016 (HealthDay News) -- The leading Zika vaccine candidate should be ready for field testing ...

  19. Field Testing of Environmentally Friendly Drilling System

    Energy Technology Data Exchange (ETDEWEB)

    David Burnett

    2009-05-31

    The Environmentally Friendly Drilling (EFD) program addresses new low-impact technology that reduces the footprint of drilling activities, integrates light weight drilling rigs with reduced emission engine packages, addresses on-site waste management, optimizes the systems to fit the needs of a specific development sites and provides stewardship of the environment. In addition, the program includes industry, the public, environmental organizations, and elected officials in a collaboration that addresses concerns on development of unconventional natural gas resources in environmentally sensitive areas. The EFD program provides the fundamentals to result in greater access, reasonable regulatory controls, lower development cost and reduction of the environmental footprint associated with operations for unconventional natural gas. Industry Sponsors have supported the program with significant financial and technical support. This final report compendium is organized into segments corresponding directly with the DOE approved scope of work for the term 2005-2009 (10 Sections). Each specific project is defined by (a) its goals, (b) its deliverable, and (c) its future direction. A web site has been established that contains all of these detailed engineering reports produced with their efforts. The goals of the project are to (1) identify critical enabling technologies for a prototype low-impact drilling system, (2) test the prototype systems in field laboratories, and (3) demonstrate the advanced technology to show how these practices would benefit the environment.

  20. Results of the fourth Hanna field test

    Energy Technology Data Exchange (ETDEWEB)

    Covell, J. R.; Wojdac, L. F.; Barbour, F. A.; Gardner, G. W.; Glass, R.; Hommert, P. J.

    1980-01-01

    The second phase (Hanna IVB) of a coal gasification experiment near Hanna, Wyoming, was completed in September 1979. The experiment attempted to link and gasify coal between process wells spaced 34.3 meters apart. Intermediate wells were positioned between the process wells so that the link could be relayed over shorter distances. Reverse combustion linking was attempted over a 22.9-meter and a 11.4-meter distance of the total well spacing. Thermal activity was generally noted in the upper 3 meters of the coal seam during the link. Two attempts to gasify over the 34.3-meter distance resulted in the propagation of the burn front at the coal overburden interface. Post-burn evaluation indicates fractures as major influencing factors of the combustion process. The Hanna IVB field test provided much insight into influence that geologic features have on in situ coal combustion. The influence of these faults, permeable zones, and cleats, on the air flow patterns can drastically change the overall results of a gasification experiment and should be studied further. The overall results of Hanna IVB were discouraging because of the rapid decline in the heating values for the production gas and the amount of coal gasified. With more complete geologic characerization prior to experimentation and proper well completions, it is believed that most of the subsurface operational problems encountered during Hanna IV could have been avoided.

  1. Field Test Results on Natural Field IP Method

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    In this paper the authors propose the natural field induced polarization (IP) method and present the way to pick up IP effect. The relations between the object and anomaly are studied by taking field experiments as examples. The effectiveness and usability of the method are testified.

  2. Field Test of Enhanced Remedial Amendment Delivery Using a Shear-Thinning Fluid

    Energy Technology Data Exchange (ETDEWEB)

    Truex, Michael J.; Vermeul, Vincent R.; Adamson, David; Oostrom, Martinus; Zhong, Lirong; Mackley, Rob D.; Fritz, Brad G.; Horner, Jacob A.; Johnson, Timothy C.; Thomle, Jonathan N.; Newcomer, Darrell R.; Johnson, Christian D.; Rysz, Michal; Wietsma, Thomas W.; Newell, Charles J.

    2015-03-01

    Heterogeneity of hydraulic properties in aquifers may lead to contaminants residing in lower-permeability zones where it is difficult to deliver remediation amendments using conventional injection processes. The focus of this effort is to examine use of a shear-thinning fluid (STF) to improve the uniformity of remedial amendment distribution within a heterogeneous aquifer. Previous studies have demonstrated the significant potential of STFs for improving remedial amendment delivery in heterogeneous aquifers, but quantitative evaluation of these improvements from field applications are lacking. A field-scale test was conducted that compares data from successive injection of a tracer in water followed by injection of a tracer in a STF to evaluate the impact of the STF on tracer distribution uniformity in the presence of permeability contrasts within the targeted injection zone. Data from tracer breakthrough at multiple depth-discrete monitoring intervals and electrical resistivity tomography showed that inclusion of STF in the injection solution slowed movement in high-permeability pathways, improved delivery of amendment to low-permeability materials, and resulted in better uniformity in injected fluid distribution within the targeted treatment zone.

  3. Comparison of in-furnace dry sorbent injection full-scale tests with laboratory-scale sulfation correlations

    Energy Technology Data Exchange (ETDEWEB)

    Collado, F.J. [University of Zaragoza, Zaragoza (Spain)

    2003-10-01

    In an effort to limit SO{sub 2} emissions to the current EU air pollutant regulations, flue gas desulfurization tests were performed with in-furnace dry sorbent, Ca(OH){sub 2}, injection technology in the Spanish coal power station 'Litoral.' The measured SO{sub 2} removals 19.5% using a CaS ratio of 3 for a coal containing 0.53% of sulfur, and 26.4% with Ca/S=1.75 for a coal with 0.73% of sulfur were lower than predicted through a 1-D model. Hence, it was thought that a 3-D computational fluid dynamics (CFD) simulation of the injection of sorbent particles would assist in understanding this complex process. After the turbulent velocity and temperature fields in the furnace were modeled, representative sorbent particles were injected, obtaining the temperature and SO{sub 2} concentrations encountered by the particles as a function of time. These data were the input to the global sulfur capture model used to simultaneously analyze calcination, sintering and sulfation. The simulation compared well with the data measured in the power station, thus verifying laboratory-scale correlations. The main conclusion is that the first temperatures encountered by the particles (in addition to the mean diameter, the sulfur content and the Ca/S ratio) control the sulfur retention. Furthermore, it is extremely difficult to accurately predict these temperatures without a CFD simulation. Low retentions were due to low sulfur concentration, the high mean diameter of the particles, and the position of the injection nozzles.

  4. Progress in crosswell induction imaging for EOR: field system design and field testing

    Energy Technology Data Exchange (ETDEWEB)

    Kirkendall, B A; Lewis, J P; Hunter, S L; Harben, P E

    1999-03-04

    At Lawrence Livermore National Laboratory (LLNL), we are continuing our effort to develop improved crosswell low-frequency electromagnetic imaging techniques, which are used to map in situ steamflood and waterflood movement during enhanced oil recovery (EOR) operations. Toward this effort, we procured two new borehole-logging field vehicles, and developed and integrated new crosswell electromagnetic transmitter and receiver data acquisition and control systems into these vehicles. We tested this new acquisition system by conducting a suite of background measurements and repeatability experiments at the Richmond Field Station in Richmond, California. Repeatability of a given scan in which the receiver was fixed and the transmitter position was varied over 60 m in 0.2-m increments resulted in amplitude differences of less than 0.6% and phase differences of less than 0.54 deg. Forward modeling produced a resistivity map fully consistent with well log data from the Richmond Field Station. In addition, modeling results suggest (1) that residual high-conductivity saltwater, injected in 1993 and pumped out in 1995, is present at the site and (2) that it has diffused outward from the original target strata. To develop crosswell electromagnetic imaging into a viable commercial product, our future research must be a two-fold approach: (1) improved quantification of system noise through experiments such as ferromagnetic core characterization as a function of temperature, and (2) development of procedures and codes to account for steel-cased hole scenarios.

  5. Current profile redistribution driven by neutral beam injection in a reversed-field pinch

    Science.gov (United States)

    Parke, E.; Anderson, J. K.; Brower, D. L.; Den Hartog, D. J.; Ding, W. X.; Johnson, C. A.; Lin, L.

    2016-05-01

    Neutral beam injection in reversed-field pinch (RFP) plasmas on the Madison Symmetric Torus [Dexter et al., Fusion Sci. Technol. 19, 131 (1991)] drives current redistribution with increased on-axis current density but negligible net current drive. Internal fluctuations correlated with tearing modes are observed on multiple diagnostics; the behavior of tearing mode correlated structures is consistent with flattening of the safety factor profile. The first application of a parametrized model for island flattening to temperature fluctuations in an RFP allows inferrence of rational surface locations for multiple tearing modes. The m = 1, n = 6 mode is observed to shift inward by 1.1 ± 0.6 cm with neutral beam injection. Tearing mode rational surface measurements provide a strong constraint for equilibrium reconstruction, with an estimated reduction of q0 by 5% and an increase in on-axis current density of 8% ± 5%. The inferred on-axis current drive is consistent with estimates of fast ion density using TRANSP [Goldston et al., J. Comput. Phys. 43, 61 (1981)].

  6. Current profile redistribution driven by neutral beam injection in a reversed-field pinch

    Energy Technology Data Exchange (ETDEWEB)

    Parke, E. [Department of Physics and Astronomy, University of California Los Angeles 475 Portola Plaza, Los Angeles, California 90095 (United States); Department of Physics, University of Wisconsin-Madison 1150 University Ave., Madison, Wisconsin 53706 (United States); Anderson, J. K.; Den Hartog, D. J. [Department of Physics, University of Wisconsin-Madison 1150 University Ave., Madison, Wisconsin 53706 (United States); Brower, D. L.; Ding, W. X.; Lin, L. [Department of Physics and Astronomy, University of California Los Angeles 475 Portola Plaza, Los Angeles, California 90095 (United States); Johnson, C. A. [Department of Physics, University of Wisconsin-Madison 1150 University Ave., Madison, Wisconsin 53706 (United States); Department of Physics, Auburn University 206 Allison Laboratory, Auburn, Alabama 36849 (United States)

    2016-05-15

    Neutral beam injection in reversed-field pinch (RFP) plasmas on the Madison Symmetric Torus [Dexter et al., Fusion Sci. Technol. 19, 131 (1991)] drives current redistribution with increased on-axis current density but negligible net current drive. Internal fluctuations correlated with tearing modes are observed on multiple diagnostics; the behavior of tearing mode correlated structures is consistent with flattening of the safety factor profile. The first application of a parametrized model for island flattening to temperature fluctuations in an RFP allows inferrence of rational surface locations for multiple tearing modes. The m = 1, n = 6 mode is observed to shift inward by 1.1 ± 0.6 cm with neutral beam injection. Tearing mode rational surface measurements provide a strong constraint for equilibrium reconstruction, with an estimated reduction of q{sub 0} by 5% and an increase in on-axis current density of 8% ± 5%. The inferred on-axis current drive is consistent with estimates of fast ion density using TRANSP [Goldston et al., J. Comput. Phys. 43, 61 (1981)].

  7. Determination of ephedrine and pseudoephedrine by field-amplified sample injection capillary electrophoresis.

    Science.gov (United States)

    Deng, Dongli; Deng, Hao; Zhang, Lichun; Su, Yingying

    2014-04-01

    A simple and rapid capillary electrophoresis method was developed for the separation and determination of ephedrine (E) and pseudoephedrine (PE) in a buffer solution containing 80 mM of NaH2PO4 (pH 3.0), 15 mM of β-cyclodextrin and 0.3% of hydroxypropyl methylcellulose. The field-amplified sample injection (FASI) technique was applied to the online concentration of the alkaloids. With FASI in the presence of a low conductivity solvent plug (water), an approximately 1,000-fold improvement in sensitivity was achieved without any loss of separation efficiency when compared to conventional sample injection. Under these optimized conditions, a baseline separation of the two analytes was achieved within 16 min and the detection limits for E and PE were 0.7 and 0.6 µg/L, respectively. Without expensive instruments or labeling of the compounds, the limits of detection for E and PE obtained by the proposed method are comparable with (or even lower than) those obtained by capillary electrophoresis laser-induced fluorescence, liquid chromatography-tandem mass spectrometry and gas chromatography-mass spectrometry. The method was validated in terms of precision, linearity and accuracy, and successfully applied for the determination of the two alkaloids in Ephedra herbs.

  8. Large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory. Summary report 2008

    Energy Technology Data Exchange (ETDEWEB)

    Cuss, R.J.; Harrington, J.F.; Noy, D.J. (British Geological Survey (United Kingdom))

    2010-02-15

    This report describes the set-up, operation and observations from the first 1,385 days (3.8 years) of the large scale gas injection test (Lasgit) experiment conducted at the Aespoe Hard Rock Laboratory. During this time the bentonite buffer has been artificially hydrated and has given new insight into the evolution of the buffer. After 2 years (849 days) of artificial hydration a canister filter was identified to perform a series of hydraulic and gas tests, a period that lasted 268 days. The results from the gas test showed that the full-scale bentonite buffer behaved in a similar way to previous laboratory experiments. This confirms the up-scaling of laboratory observations with the addition of considerable information on the stress responses throughout the deposition hole. During the gas testing stage, the buffer was continued to artificially hydrate. Hydraulic results, from controlled and uncontrolled events, show that the buffer continues to mature and has yet to reach full maturation. Lasgit has yielded high quality data relating to the hydration of the bentonite and the evolution in hydrogeological properties adjacent to the deposition hole. The initial hydraulic and gas injection tests confirm the correct working of all control and data acquisition systems. Lasgit has been in successful operation for in excess of 1,385 days

  9. WFC3/UVIS Charge Injection Behavior: Results of an Initial Test

    Science.gov (United States)

    Bushouse, H.; Baggett, S.; Gilliland, R.; Noeske, K.; Petro, L.

    2011-01-01

    The WFC3 CCD Charge Injection (CI) capability has been tested on-orbit in Cycle18 calibration program 12348. Bias, dark, and science exposures of star cluster NGC 104 have been obtained in all commandable CI modes. Super-bias images were constructed for each CI mode and used to calibrate the NGC 104 exposures. Analysis has shown that the CI mode is working as expected, producing injected signals of ~15000 e-/pix. The CI signal is stable and repeatable to a level of a few e-/pix. CI rows in calibrated science images have mean residual signals of a few e-/pix with 1-sigma noise of ~18 e-/pix. Noise in science images in the rows in between CI varies from 3.5-6.5 e-/pix, compared to ~3.4 e-/pix in non-CI images.

  10. COMPARISON OF SQL INJECTION DETECTION TECHNIQUES WHICH USES CHI-SQUARE TEST

    Directory of Open Access Journals (Sweden)

    KHWAIRAKPAM AMITAB,

    2011-06-01

    Full Text Available Database driven by interactive web applications are at risk of SQL Injection Attacks (SQLIA these applications accept user inputs and use them to form SQL statements. During SQL injection process the attacker inputs malicious SQL query segments which will result in different database request. SQLIA can be use to bypass authentication control and also extract and/or modify valuable information. In order to encounter such type of threats different techniques are purposed by researchers but most of the implemented approaches which usesanomaly detection model have very high false alert. In this paper we have analyze existing detection techniques that uses Chi-square test. And we have evaluated these techniques against SQLIA.

  11. Reactive transport modeling of CO2 injection in the Farnsworth, Texas hydrocarbon field

    Science.gov (United States)

    Ahmmed, B.; Appold, M. S.; McPherson, B. J. O. L.; Grigg, R.; White, M. D.

    2014-12-01

    The Farnsworth hydrocarbon field in northern Texas has been an experimental site for CO2 sequestration and enhanced oil recovery for the U.S. Department of Energy-sponsored Southwest Partnership (SWP) since April, 2013. CO2 is to be injected into the Pennsylvanian Morrow Sandstone at a rate of 200,000 tonnes per year for at least five years. The Morrow is a quartz-rich sandstone that lies at a depth of about 2400 m. Pore water in the Morrow has a total dissolved solids content of about 3600 mg/L dominated by Na, Cl, bicarbonate, and Ca. A reactive solute transport model was constructed for a 1700 × 1700 × 95 m volume using the TOUGHREACT software and the ECO2N equation of state for aqueous brine and CO2. Simulations were carried out to 100 years. The results showed immiscible CO2 gas to be concentrated in a lateral plume extending radially from the well screen, its ascent impeded by vigorous lateral groundwater flow in the more permeable upper Morrow. CO2 was much more widespread in aqueous solution, lowering pH throughout much of the model volume after 100 years, to a minimum of about 4.7. The low reactivity of the Morrow Sandstone due to its quartz-rich matrix and dilute pore fluid resulted in little mineral precipitation or dissolution, with net volume changes for any mineral no higher than order 10-4. The simulations predicted net dissolution of albite, calcite, and chlorite, and net precipitation of dawsonite, illite, and magnesite. The Morrow matrix was predicted to undergo slight net dissolution overall, resulting in porosity increases of up to 0.01%, suggesting that the Morrow would be resistant to significant changes in hydraulic properties as a result of the proposed amount of CO2 injection. For the 100 year simulation times calculated thus far, only a small fraction of the injected CO2 would be sequestered as carbonate minerals, with most of the injected CO2 dissolved in the aqueous phase.

  12. Ion Source for Neutral beam injection meant for plasma and magnetic field diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Vainionpaa, Jaakko Hannes; Leung, Ka Ngo; Gough, Richard A.; Kwan, Joe W.; Levinton, Fred

    2007-06-01

    At the Lawrence Berkeley National Laboratory (LBNL) a diagnostic neutral beam injection system for measuring plasma parameters, flow velocity, and local magnetic field is being developed. The systems is designed to have a 90 % proton fraction and small divergence with beam current at 5-6 A and a pulse length of {approx}1 s occurring once every 1-2 min. The ion source needs to generate uniform plasma over a large (8 cm x 5 cm) extraction area. For this application, we have compared RF driven multicusp ion sources operating with either an external or an internal antenna in similar ion source geometry. The ion beam will be made of an array of six sheet-shaped beamlets. The design is optimized using computer simulation programs.

  13. Thermal and Magnetic Field Sensors Based on Injection-coupled Devices

    Directory of Open Access Journals (Sweden)

    V.N. Murashev

    2014-07-01

    Full Text Available Operation principle and possible applications of a novel type of silicon integrated circuit (IC device –injection-coupled device (ICD – are addressed. Examples of possible ICD electrical and physical designs are examined in detail. These are based on the existing CMOS and use bipolar technologies. It is shown that in active mode only one cell of ICD-based sensor chain consumes power. This circumstance enables one to achieve an extraordinarily low power consumption compared to the CMOS ICs. This is because the power consumption of an ICD as a whole is not different of that of a single cell in its IC matrix. These advantages make ICDs highly attractive for a number of important applications, such as, e.g., radiation detectors or magnetic and thermal field detectors.

  14. Hot gas injection as an artificial lift system through a concentric tubing completion in a heavy oil well, Pilon field, Faja Petrolifera del Orinoco

    Energy Technology Data Exchange (ETDEWEB)

    Marfissi, S.; Lujan, A. [PDVSA EandP (Venezuela)

    2011-07-01

    The Pilon Field in the Morichal District, Venezuela is producing heavy oil with numerous gas lift wells. Some of these wells are now inactive due to casing damage. The purpose of this paper is to assess the benefits of using hot gas injection as an artificial lift system through a concentric tubing completion in such wells. A pilot test was conducted on a well presenting a low water cut and 12 degree API, an indirect fire heater was installed near the wells. Results showed that heat losses were minimized thanks to the concentric pipe completion. In addition hot gas injection resulted in an oil production increase of 57%. The hot gas injection method used with a concentric tubing completion was proved to be a good alternative to the use of diluent but an economic analysis is nevertheless recommended to determine the costs of installing heating equipment.

  15. Impact of supercritical CO2 injection on petrophysical and rock mechanics properties of chalk: an experimental study on chalk from South Arne field, North Sea

    DEFF Research Database (Denmark)

    Alam, Mohammad Monzurul; Hjuler, Morten Leth; Christensen, Helle Foged

    2011-01-01

    Changes in chalk due to EOR by injecting supercritical CO2 (CO2-EOR) can ideally be predicted by applying geophysical methods designed from laboratory-determined petrophysical and rock mechanics properties. A series of petrophysical and rock mechanics tests were performed on Ekofisk Formation...... and Tor Formation chalk of the South Arne field to reveal the changes in petrophysical and rock mechanics properties of chalk due to the injection of CO2 at supercritical state. An increase in porosity and decrease in specific surface was observed due to injection of supercritical CO2. This indicates...... that a reaction between CO2 enriched water and particles takes place which smoothens the particle surface. Accordingly, partial increase in permeability was also noticed. An effect is also observed from the decrease in pore-space stiffness, calculated from sonic velocity. No significant effect on wettability...

  16. Interactive Diagnostic Testing: Field Trial Results.

    Science.gov (United States)

    McArthur, David L.; Cabello, Beverly

    A diagnostic testing system managed by microcomputer was evaluated in actual use at the upper elementary level. Two tests specifically designed to yield diagnostic indicators of erroneous performance were utilized, one a test of pronoun usage, the other a test of reading comprehension. The results are interpreted from the standpoint of the…

  17. Effect of injecting cold water on oil-output of the beds of the Uzen' field

    Energy Technology Data Exchange (ETDEWEB)

    Borisov, Yu.P.; Kil' dibekova, L.I.; Rozenberg, M.D.; Safronov, S.V.; Teslyuk, Ye.V.

    1979-01-01

    At the Uzen' field, 254 million m/sup 3/ of cold water were injected into the oil area with average temperature 15-16/sup 0/C. This resulted in cooling of the rock-collectors on the order of 538.4 million m/sup 3/ and decrease in oil output by 9.4% as compared to injection of only hot water.

  18. Experiences with urine drug testing by police among people who inject drugs in Bangkok, Thailand.

    Science.gov (United States)

    Hayashi, Kanna; Ti, Lianping; Buxton, Jane A; Kaplan, Karyn; Suwannawong, Paisan; Wood, Evan; Kerr, Thomas

    2014-03-01

    Thailand has relied on drug law enforcement in an effort to curb illicit drug use. While anecdotal reports suggest that Thai police frequently use urine toxicology to identify drug users, little is known about the prevalence or impacts of this practice among people who inject drugs (IDU). Therefore, we sought to examine experiences with urine drug testing by police among IDU in Bangkok. Data were derived from a community-recruited sample of IDU in Bangkok participating in the Mitsampan Community Research Project between July and October 2011. We assessed the prevalence and correlates of being subjected to urine toxicology testing by police using multivariate Poisson regression. In total, 438 IDU participated in this study, with 293 (66.9%) participants reporting having been tested for illicit drugs by police. In multivariate analyses, reports of drug testing by police were independently and positively associated with younger age (adjusted prevalence ratio [APR]: 1.28), a history of methamphetamine injection (APR: 1.22), a history of incarceration (APR: 1.21), having been in compulsory drug detention (APR: 1.43), avoiding healthcare (APR: 1.15), and HIV seropositivity (APR: 1.19), and negatively associated with access to voluntary drug treatment (APR: 0.82) (all p<0.05). A high proportion of IDU in Bangkok were subjected to drug testing by police. Young people and methamphetamine injectors were more likely to have been tested. The findings indicate that drug testing by police is associated with the compulsory drug detention system and may be interfering with IDU's access to healthcare and voluntary drug treatment. These findings raise concern about the widespread practice of drug testing by police and its associated impacts. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. A tracer test at the Beowawe geothermal field, Nevada, using fluorescein and tinopal CBS

    Energy Technology Data Exchange (ETDEWEB)

    Rose, P.E.; Adams, M.C. [Univ. of Utah, Salt Lake City, UT (United States); Benoit, D. [Oxbow Power Services, Inc., Reno, NV (United States)

    1995-12-31

    An interwell tracer test using fluorescein and tinopal CBS was performed at the Beowawe geothermal field in north-central Nevada in order to assess the effects of recent changes to the injection strategy. Fluorescein return curves established injection-production flow patterns and verified that produced water is being reinjected into a region of the reservoir that is in excellent communication with the production wells. An analysis of the tinopal CBS return curves indicated that tinopal CBS was apparently strongly adsorbed onto the reservoir rock. The fluorescein return curves were used to estimate the overall (fractures and matrix) reservoir volume.

  20. Investigation of charge injection and transport behavior in multilayer structure consisted of ferromagnetic metal and organic polymer under external fields

    Science.gov (United States)

    Zhao, Hua; Meng, Wei-Feng

    2017-10-01

    In this paper a five layer organic electronic device with alternately placed ferromagnetic metals and organic polymers: ferromagnetic metal/organic layer/ferromagnetic metal/organic layer/ferromagnetic metal, which is injected a spin-polarized electron from outsides, is studied theoretically using one-dimensional tight binding model Hamiltonian. We calculated equilibrium state behavior after an electron with spin is injected into the organic layer of this structure, charge density distribution and spin polarization density distribution of this injected spin-polarized electron, and mainly studied possible transport behavior of the injected spin polarized electron in this multilayer structure under different external electric fields. We analyze the physical process of the injected electron in this multilayer system. It is found by our calculation that the injected spin polarized electron exists as an electron-polaron state with spin polarization in the organic layer and it can pass through the middle ferromagnetic layer from the right-hand organic layer to the left-hand organic layer by the action of increasing external electric fields, which indicates that this structure may be used as a possible spin-polarized charge electronic device and also may provide a theoretical base for the organic electronic devices and it is also found that in the boundaries between the ferromagnetic layer and the organic layer there exist induced interface local dipoles due to the external electric fields.

  1. Summary of Injection pre-cleaning tests performed on October 27, 2010

    CERN Document Server

    Boccardi, A; Roncarolo, F; Hofle, W; Shaposhnikova, E; Valuch, D; Kain, V; Bracco, C; Goddard, B; Meddahi, M; Uythoven, J; Gianfelice, E

    2010-01-01

    During the LHC filling, in order to reduce the particle losses coming from the un-bunched circulating beam, pre-cleaning of the injection slot has been tried. The cleaning of the injection slot, using 3 s pulse starting from the first bunch of the next batch injection, was performed before the injection of the requested batches. The cleaning was then moved to the next injection slot, just prior to the on-going injection request. The results were extremely encouraging, showing much less particle losses when both the cleaning of the injection slot and the abort gap are active and preventing diffusion of uncaptured beam into the injection slot.

  2. The four-meter confrontation visual field test.

    OpenAIRE

    Kodsi, S R; Younge, B. R.

    1992-01-01

    The 4-m confrontation visual field test has been successfully used at the Mayo Clinic for many years in addition to the standard 0.5-m confrontation visual field test. The 4-m confrontation visual field test is a test of macular function and can identify small central or paracentral scotomas that the examiner may not find when the patient is tested only at 0.5 m. Also, macular sparing in homonymous hemianopias and quadrantanopias may be identified with the 4-m confrontation visual field test....

  3. Test of Nonlocality with an Atom-Field Entangled State

    Institute of Scientific and Technical Information of China (English)

    ZHENG Shi-Biao

    2002-01-01

    We propose a scheme for the test of nonlocality with atom-field entanglement. An atom is sent through a cavity filled with a coherent field with a small amplitude. The dispersive interaction leads to atom-field entanglement.Then the field is driven by a classical current. The Bell inequality can be tested by the joint measurement of the parity of the field and the atomic state.

  4. Design and Operation of Laboratory Combustion Cell for Air Injection into Light Oil Reservoirs: Potential Application in Sindh Field

    Directory of Open Access Journals (Sweden)

    Abdul Haque Tunio

    2011-01-01

    Full Text Available Historical experimental work on the combustion oil recovery processes consists of both laboratory and field studies. Although field experiments are the ultimate test of any oil recovery process, they are costly, time consuming and difficult to analyze quantitatively. Laboratory CC (Combustion Cell experiments are cost effective and less time consuming, but are subject to scaling and interpretation challenges. Experimental set up has been developed to understand air injection process for improving oil recovery from light oil reservoirs taking into account the sand pack petro physical and fluid properties. Some important design problems; operational criteria and considerations important to interpretation of results are pointed out. To replicate subsurface reservoir conditions or pressure and temperature, experiments up to 6895 KPa, at non-isothermal conditions with 5oC/min ramp-up are performed on unconsolidated cores with reservoir oil samples. Correlations were obtained for low temperature oxidation rate of oil, the fuel deposition rate and the rate of burning fuel as a fuel concentration. Various parameters such as (sand pack, pressure, oil saturation and flow rate/air flux were changed to investigate their impact on reaction and chemical nature of the fuel burned. To determine the importance of distribution and pyrolysis on these reactions, the hydrogen-carbon ratio and m-ratio was calculated. For further confirmation Arrhenius graphs were drawn by assuming 1.0 order of reaction with carbon concentration which is also confirmed.This research will contribute to the overall understanding of air injection process;help to determine the most appropriate

  5. Field Accuracy Test of Rpas Photogrammetry

    Science.gov (United States)

    Barry, P.; Coakley, R.

    2013-08-01

    Baseline Surveys Ltd is a company which specialises in the supply of accurate geospatial data, such as cadastral, topographic and engineering survey data to commercial and government bodies. Baseline Surveys Ltd invested in aerial drone photogrammetric technology and had a requirement to establish the spatial accuracy of the geographic data derived from our unmanned aerial vehicle (UAV) photogrammetry before marketing our new aerial mapping service. Having supplied the construction industry with survey data for over 20 years, we felt that is was crucial for our clients to clearly understand the accuracy of our photogrammetry so they can safely make informed spatial decisions, within the known accuracy limitations of our data. This information would also inform us on how and where UAV photogrammetry can be utilised. What we wanted to find out was the actual accuracy that can be reliably achieved using a UAV to collect data under field conditions throughout a 2 Ha site. We flew a UAV over the test area in a "lawnmower track" pattern with an 80% front and 80% side overlap; we placed 45 ground markers as check points and surveyed them in using network Real Time Kinematic Global Positioning System (RTK GPS). We specifically designed the ground markers to meet our accuracy needs. We established 10 separate ground markers as control points and inputted these into our photo modelling software, Agisoft PhotoScan. The remaining GPS coordinated check point data were added later in ArcMap to the completed orthomosaic and digital elevation model so we could accurately compare the UAV photogrammetry XYZ data with the RTK GPS XYZ data at highly reliable common points. The accuracy we achieved throughout the 45 check points was 95% reliably within 41 mm horizontally and 68 mm vertically and with an 11.7 mm ground sample distance taken from a flight altitude above ground level of 90 m.The area covered by one image was 70.2 m × 46.4 m, which equals 0.325 Ha. This finding has shown

  6. Matched injection in a helical undulator taking into account the orbit amplitude and the longitudinal magnetic field

    CERN Document Server

    Papadichev, V A

    2002-01-01

    Helical undulators are widely used in FELs because they are inexpensive and easy to fabricate. Also, because field amplitudes can be conveniently adjusted with high accuracy. Their main weakness is their use of adiabatic input and output (up to 10 periods each) for matched injection (ejection) of the electron beam in the undulator field. This leads to considerable lengthening of the undulator and optical resonator, without simultaneously providing, in a number of cases, the required injection accuracy (due to some angle error and failure to account for orbit amplitude). Here alternative methods of matched injection are described that take into account orbit amplitude and external magnetic field. The length of correcting elements does not exceed one-half of the undulator period. When the overall length of the helical undulator is large, their application permits its realization in the form of a set of successive sections with free straight gaps in which devices can be placed for measuring beam parameters and c...

  7. Impurity profiling and in-process testing of drugs for injection by fast liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    Marie-Josee Rocheleau; Elaine Larouche; Cristina Salamu; Mihaela Curca

    2012-01-01

    Liquid chromatography (LC) is considered by many as a mature technique. Nonetheless, LC technology continues to evolve driven by the need for high-throughput and high-resolution analyses. Over the past several years, small particle size packing materials have been introduced by several column manufacturers to enable fast and efficient LC separations. Several examples of pharmaceutical analyses, including impurity profiling of taxanes and atracurium besylate, in-process testing of peptides in injectable dosage form, using sub-2 um column technology are presented in this paper, demonstrating some of the capabilities and limitations of the technology.

  8. HIV Testing in Non-Injection Drug Users: Prevalence and Associated Factors.

    Science.gov (United States)

    Alves Guimarães, Rafael; Lucchese, Roselma; Lara Fernandes, Inaina; Vera, Ivânia; Goulart Rodovalho, Aurélio; Alves Guimarães, Vanessa; Cristina Silva, Graciele; Lopes de Felipe, Rodrigo; Alexandre de Castro, Paulo; Martins Ferreira, Priscilla

    2017-05-24

    The objective of this study was to estimate the prevalence of and identify factors associated with lifetime testing for the human immunodeficiency virus (HIV) in non-injection drug users (NIDU). A cross-sectional study was conducted with 323 individuals in clinics for chemical dependency in the state of Goiás in the Central-West region of Brazil. Logistic regression analysis was used to identify factors associated with lifetime HIV testing. Testing for HIV was associated with age, female gender, crack use, history of sexually transmitted infections, acquaintance with people living with HIV/AIDS and/or who had died from AIDS, and history of having received some instruction on HIV/AIDS prevention methods. It was found that only 26.6% reported having access to the HIV rapid test. We concluded determinants for HIV testing must be taken into account when planning prevention and programming strategies. These include the widening of testing coverage among NIDU, educational health actions, establishment of links between sexually transmitted infection prevention services and addiction treatment services, and the use of rapid tests to help people who are in contact with the virus learn about their HIV status, enter treatment, and improve their quality of life.

  9. Injection-induced gluteus muscle contractures: diagnosis with the "reverse Ober test" and surgical management.

    Science.gov (United States)

    Scully, William F; White, Klane K; Song, Kit M; Mosca, Vincent S

    2015-03-01

    Adoption rates are increasing in the United States and other developed countries. A large proportion of adopted children have been found to have unsuspected medical diagnoses, including orthopedic problems. One condition, termed injection-induced gluteus maximus contracture, has been previously described in several case series and can be difficult to diagnose if unfamiliar with this condition. By reviewing the etiology and pathoanatomy of this problem, as well as the typical examination findings, including the near-pathognomonic-positive "reverse Ober test," treating providers will be better prepared to recognize and properly treat this condition. This is a retrospective review of 4 patients treated at our institution for injection-induced gluteus maximus contracture. Patient history, physical examination findings, and treatment outcomes were recorded. All had undergone surgical treatment through a longitudinal incision along the posterior margin of the iliotibial band, with division of thickened, contracted gluteus tissue down to the ischial tuberosity. All 4 of the patients were adopted from orphanages in developing countries. Chief complaints of the patients varied, but physical examination findings were very consistent. Three of the 4 patients had undergone rotational osteotomies for presumed femoral retroversion before their diagnosis and treatment for injection-induced gluteus maximus contracture. All patients had concave, atrophic buttock contours and numerous punctate buttock scars. All walked with an out-toed gait and had marked apparent femoral retroversion. Each patient was found to have full hip adduction when the hip was extended but a hip abduction contracture when the hip was flexed. This finding of increasing abduction as an extended/adducted hip is flexed to 90 degrees is described as a positive "reverse Ober test." After surgical treatment, all hips could adduct to neutral from full extension to full flexion. Although common in some countries

  10. Influence of high-conductivity buffer composition on field-enhanced sample injection coupled to sweeping in CE.

    Science.gov (United States)

    Anres, Philippe; Delaunay, Nathalie; Vial, Jérôme; Thormann, Wolfgang; Gareil, Pierre

    2013-02-01

    The aim of this work was to clarify the mechanism taking place in field-enhanced sample injection coupled to sweeping and micellar EKC (FESI-Sweep-MEKC), with the utilization of two acidic high-conductivity buffers (HCBs), phosphoric acid or sodium phosphate buffer, in view of maximizing sensitivity enhancements. Using cationic model compounds in acidic media, a chemometric approach and simulations with SIMUL5 were implemented. Experimental design first enabled to identify the significant factors and their potential interactions. Simulation demonstrates the formation of moving boundaries during sample injection, which originate at the initial sample/HCB and HCB/buffer discontinuities and gradually change the compositions of HCB and BGE. With sodium phosphate buffer, the HCB conductivity increased during the injection, leading to a more efficient preconcentration by staking (about 1.6 times) than with phosphoric acid alone, for which conductivity decreased during injection. For the same injection time at constant voltage, however, a lower amount of analytes was injected with sodium phosphate buffer than with phosphoric acid. Consequently sensitivity enhancements were lower for the whole FESI-Sweep-MEKC process. This is why, in order to maximize sensitivity enhancements, it is proposed to work with sodium phosphate buffer as HCB and to use constant current during sample injection. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Magnetic Field Apparatus (MFA) Hardware Test

    Science.gov (United States)

    Anderson, Ken; Boody, April; Reed, Dave; Wang, Chung; Stuckey, Bob; Cox, Dave

    1999-01-01

    The objectives of this study are threefold: (1) Provide insight into water delivery in microgravity and determine optimal germination paper wetting for subsequent seed germination in microgravity; (2) Observe the behavior of water exposed to a strong localized magnetic field in microgravity; and (3) Simulate the flow of fixative (using water) through the hardware. The Magnetic Field Apparatus (MFA) is a new piece of hardware slated to fly on the Space Shuttle in early 2001. MFA is designed to expose plant tissue to magnets in a microgravity environment, deliver water to the plant tissue, record photographic images of plant tissue, and deliver fixative to the plant tissue.

  12. Construction and 60 kV tests of the prototype pulser for the LHC injection kicker system

    CERN Document Server

    Barnes, M J; Carlier, E; Ducimetière, L; Schröder, G; Vossenberg, Eugène B

    1999-01-01

    The European Laboratory for Particle Physics (CERN) is constructing the Large Hadron Collider (LHC). Two counter-rotating proton beams will be injected into the LHC at an energy of 450 GeV by two kicker magnet systems, producing magnetic field pulses of approximately 900 ns rise time and 6.6 mu s flat top duration with a ripple of less than +or-0.5Both injection systems are composed of 4 travelling wave kicker magnets of 2.17 m length each, powered by pulse forming networks (PFNs). To achieve the high-required kick strength of 1.2 Tm, for a compact and cost efficient design, a characteristic impedance of 5 Ohms has been chosen. The design strategy for the magnets and generators has been defined after detailed analysis of existing systems. The electrical circuit has been optimised using the circuit analysis software PSpice. Most known parasitics have been modelled. A prototype PFN has been constructed at CERN and successfully tested at 60 kV. A calibration procedure has been developed and utilised for obtainin...

  13. Geophysical monitoring of near surface CO2 injection at Svelvik - Learnings from the CO2FieldLab experiments.

    Science.gov (United States)

    Querendez, Etor; Romdhane, Anouar; Jordan, Michael; Eliasson, Peder; Grimstad, Alv-Arne

    2014-05-01

    A CO2 migration field laboratory for testing monitoring methods and tools has been established in the glaciofluvial-glaciomarine Holocene deposits of the Svelvik ridge, near Oslo (Norway). At the site, feasibility, sensitivity, acquisition geometry and usefulness of various surface and subsurface monitoring tools are investigated during controlled CO2 injection experiments. In a first stage, a shallow CO2 injection experiment was conducted in September 2011. Approximately 1700 kg of CO2 was injected at 18 m depth below surface in an unconsolidated sand formation. The objectives of this experiment were to (i) detect and, where possible, quantify migrated CO2 concentrations at the surface and very shallow subsurface, (ii) evaluate the sensitivity of the monitoring tools and (iii) study the impact of the vadose zone on observed measurements. Results showed that all deployed monitoring tools (for surface and near-surface gas monitoring, subsurface water monitoring and subsurface geophysical monitoring) where able to detect the presence of CO2 even though the CO2 plume did not migrate vertically as expected in what was thought to be an homogeneous unconsolidated sand structure. The upper part of the site revealed to be more heterogeneous than expected, mainly due to the highly variable lamination and channelling of the morainic sediments and to the presence of pebble and cobble beds sporadically showing throughout the deposits. Building on the learnings from the 18m depth injection experiment, a second experiment is being planned for a deeper injection, at a depth of 65m. Re-processing of the appraisal 2D multi-channel seismic with state-of-the-art processing techniques, like Linear Radon coherent and random noise attenuation and Full Waveform Inversion followed by pre-stack depth migration, corroborate the presence of heterogeneities at the near surface. Based on the re-interpreted seismic sections, a more realistic 3D geomodel, where the complex topography of the site

  14. Field Test and Evaluation of Engineered Biomineralization Technology for Sealing Existing Wells

    Energy Technology Data Exchange (ETDEWEB)

    Cunningham, Alfred [Montana State Univ., Bozeman, MT (United States)

    2015-12-21

    This research project addresses one of the goals of the U.S. Department of Energy (DOE) Carbon Storage Program (CSP) aimed at developing Advanced Wellbore Integrity Technologies to Ensure Permanent Geologic Carbon Storage. The technology field-tested in this research project is referred to as microbially induced calcite precipitation (MICP), which utilizes a biologically-based process to precipitate calcium carbonate. If properly controlled MICP can successfully seal fractures, high permeability zones, and compromised wellbore cement in the vicinity of wellbores and in nearby caprock, thereby improving the storage security of geologically-stored carbon dioxide. This report describes an MICP sealing field test performed on a 24.4 cm (9.625 inch) diameter well located on the Gorgas Steam Generation facility near Jasper, Alabama. The research was aimed at (1) developing methods for delivering MICP promoting fluids downhole using conventional oil field technologies and (2) assessing the ability of MICP to seal cement and formation fractures in the near wellbore region in a sandstone formation. Both objectives were accomplished successfully during a field test performed during the period April 1-11, 2014. The test resulted in complete biomineralization sealing of a horizontal fracture located 340.7 m (1118 feet) below ground surface. A total of 24 calcium injections and six microbial inoculation injections were required over a three day period in order to achieve complete sealing. The fractured region was considered completely sealed when it was no longer possible to inject fluids into the formation without exceeding the initial formation fracture pressure. The test was accomplished using conventional oil field technology including an 11.4 L (3.0 gallon) wireline dump bailer for injecting the biomineralization materials downhole. Metrics indicating successful MICP sealing included reduced injectivity during seal formation, reduction in pressure falloff, and

  15. Application of the BacT/ALERTR 3D system for sterility testing of injectable products

    Directory of Open Access Journals (Sweden)

    Adriana Bugno

    2015-09-01

    Full Text Available Sterility testing as described in the pharmacopoeia compendia requires a 14-day incubation period to obtain an analytical result. Alternative methods that could be applied to evaluating product sterility are especially interesting due to the possibility of reducing this incubation period and thus the associated costs. The aims of this study were to evaluate the performance of the BacT/ALERTR 3D system in detecting microorganisms in large-volume parenteral solutions that were intentionally contaminated and to compare this system to pharmacopoeia sterility testing using the membrane filtration method. The results indicated that there were no significant differences between the methods regarding the ability to detect microbial contamination; however, detection with the BacT/ALERTR 3D system was faster compared to the pharmacopoeia method. Therefore, the BacT/ALERTR 3D system is a viable alternative for assessing the sterility of injectable products.

  16. Field Cone Penetration Tests with Various Penetration Rates - Test Results

    DEFF Research Database (Denmark)

    Poulsen, Rikke; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    The test site is located at Nordre Ringgade near the town called Dronninglund in the northern Jutland in Denmark. The site area is relatively flat, and was chosen because it has a size of approximately 3 ha and contains a relatively thick deposit of silty soils. Furthermore the groundwater...... was encountered at approximately 0.2-0.6 m below the ground level. The soil stratigraphy of the test site was before test start identified by geotechnical borings results. The geotechnical borings indicated that the site contains of sandy silt with clay stripes from approx. 4.0 to 10 m. In the top the silty soil...... is very sandy with few clay stripes, and gradually the clay stripes increases wherefore the soil from approx. 10 m contains of clay with sandy silt stripes. Large soil sample was also collected from the test site in order to determine basic soil properties in the laboratory....

  17. Calculation of prompt loss and toroidal field ripple loss under neutral beam injection on EAST

    Science.gov (United States)

    Wu, Bin; Hao, Baolong; White, Roscoe; Wang, Jinfang; Zang, Qing; Han, Xiaofeng; Hu, Chundong

    2017-02-01

    Neutral beam injection is a major auxiliary heating method in the EAST experimental campaign. This paper gives detailed calculations of beam loss with different plasma equilibria using the guiding center code ORBIT and NUBEAM/TRANSP. Increasing plasma current can dramatically lower the beam ion prompt loss and ripple loss. Countercurrent beam injection gives a much larger prompt loss fraction than co-injection, and ripple-induced collisionless stochastic diffusion is the dominant loss channel.

  18. Field Measurements of Gasoline Direct Injection Emission Factors: Spatial and Seasonal Variability.

    Science.gov (United States)

    Zimmerman, Naomi; Wang, Jonathan M; Jeong, Cheol-Heon; Ramos, Manuel; Hilker, Nathan; Healy, Robert M; Sabaliauskas, Kelly; Wallace, James S; Evans, Greg J

    2016-02-16

    Four field campaigns were conducted between February 2014 and January 2015 to measure emissions from light-duty gasoline direct injection (GDI) vehicles (2013 Ford Focus) in an urban near-road environment in Toronto, Canada. Measurements of CO2, CO, NOx, black carbon (BC), benzene, toluene, ethylbenzene-xylenes (BTEX), and size-resolved particle number (PN) were recorded 15 m from the roadway and converted to fuel-based emission factors (EFs). Other than for NOx and CO, the GDI engine had elevated emissions compared to the Toronto fleet, with BC EFs in the 73rd percentile, BTEX EFs in the 80-90th percentile, and PN EFs in the 75th percentile during wintertime measurements. Additionally, for three campaigns, a second platform for measuring PN and CO2 was placed 1.5-3 m from the roadway to quantify changes in PN with distance from point of emission. GDI vehicle PN EFs were found to increase by up to 240% with increasing distance from the roadway, predominantly due to an increasing fraction of sub-40 nm particles. PN and BC EFs from the same engine technology were also measured in the laboratory. BC EFs agreed within 20% between the laboratory and real-world measurements; however, laboratory PN EFs were an order of magnitude lower due to exhaust conditioning.

  19. Infrared study of charge injection in organic field-effect transistors

    Science.gov (United States)

    Li, Zhiqiang

    2008-03-01

    We present a systematic infrared (IR) spectroscopic study of charge injection in organic field-effect transistors (FET). These experiments have revealed new unexpected aspects of both polymers and molecular crystals. IR spectromicroscopy was employed to image the charges in poly(3-hexylthiophene) (P3HT) FETs. The charge density profile in the conducting channel uncovers a density-dependent mobility in P3HT due to disorder effects. Our IR studies of single crystal rubrene based FETs show that charge transport in these devices at room temperature is governed by light quasiparticles in molecular orbital bands. This result is at variance with the common beliefs of polaron formation in molecular solids. The above experiments have demonstrated the unique potential of IR spectroscopy for investigating physical phenomena at the nanoscale occurring at the semiconductor-insulator interface in FET devices. This work is in collaboration with G. M. Wang, D. Moses, A. J. Heeger (UCSB), V. Podzorov, M.E. Gershenson (Rutgers), Z. Hao, M. C. Martin (ALS), N. Sai, A. D. Meyertholen, M. M. Fogler, M. Di Ventra and D. N. Basov (UCSD).

  20. Production and Injection Induced Changes at The Geysers Geothermal Field, CA, USA

    Science.gov (United States)

    Gritto, R.; Jarpe, S.; Boyle, K. L.; Hutchings, L. J.

    2011-12-01

    Induced seismicity related to the exploitation of geothermal fields has caused concern and objection from the public against the operation of geothermal reservoirs in close proximity to population centers. Production at the EGS sites in Basel (Switzerland) was stopped after renewed seismicity caused concern and objection from the public in the city. A planned expansion of the EGS site in Soultz-sous-forêt (France) was suspended after attempts to generate increased permeability through hydrofracturing of the reservoir rock generated an increase in seismicity. As a consequence of these concerns and objections it becomes imperative to understand the differences between naturally occurring and induced events and their relationship to induced stress changes in the reservoir if sustained generation of geothermal energy is the goal. We will address seismicity trends at The Geysers Geothermal Reservoir, CA USA, to understand the role of historical seismicity associated with past injection of water and/or production of steam. The paper will present results of time-lapse tomography to evaluate and quantify temporal changes of the physical parameters in the reservoir. Seismic data collected by the Lawrence Berkeley National Lab (LBNL) seismic network from 2003 through present, were analyzed to delineate regions where compressional and shear-wave velocities indicate changes in reservoir properties.

  1. Monitoring dyke injection and strain field evolution using shear-wave splitting.

    Science.gov (United States)

    Kendall, J.-M.; Verdon, J. P.; Keir, D.; Baird, A.

    2012-04-01

    Magma storage and dyke injection in the shallow crust is a fundamental process in rifting and volcanic environments. The dyking will tend to align with directions of maximum compressive stress, and the associated aligned fracturing and melt migration provides a very effective means of generating seismic anisotropy. Observations of shear-wave splitting provide one of the most unambiguous indicators of such anisotropy. As such, shear-wave splitting can be used to monitor the evolving strain field in volcanic and rifting environments. Here we apply lessons learned from monitoring fracture propagation during the hydraulic stimulation of tight-gas reservoirs. In a number of experiments we observe spatial and temporal variations in shear-wave splitting magnitude and orientation. We invert shear-wave observations for fracture properties, including the tangential and normal compliance, the ratio of which is a good indicator of fluid flow and permeability. Frequency dependent affects can be also used to indicate the length scales of the causative cracks or fractures. We apply these insights to microseismic data recently acquired across the volcanically active Afar triple junction in Ethiopia. The pattern of S-wave splitting in Afar is best explained by anisotropy from deformation-related structures, with the dramatic change in splitting parameters into the rift axis from the increased density of dyke-induced faulting combined with a contribution from oriented melt pockets near volcanic centres. The results help in our understanding of the role of melt in strain accommodation in rifting and volcanic environments.

  2. Field studies of streamflow generation using natural and injected tracers on Bickford and Walker Branch Watersheds

    Energy Technology Data Exchange (ETDEWEB)

    Genereux, D.; Hemond, H. [Massachusetts Inst. of Tech., Cambridge, MA (United States). Dept. of Civil Engineering; Mulholland, P. [Oak Ridge National Lab., TN (United States)

    1992-05-01

    Field studies of streamflow generation were undertaken on two forested watersheds, the West Road subcatchment of Bickford Watershed in central Massachusetts and the West Fork of Walker Branch Watershed in eastern Tennessee. A major component of the research was development of a two-stage methodology for the use of naturally-occurring {sup 222}Rn as a tracer. The first of the two stages was solving a mass-balance equation for {sup 222}Rn around a stream reach of interest in order to calculate Rn{sub q}, the {sup 222}Rn content of the lateral inflow to the reach; a conservative tracer (chloride) and a volatile tracer (propane) were injected into the study stream to account for lateral inflow to, and volatilization from, the study reach. The second stage involved quantitative comparison of Rn{sub q} to the measured {sup 222}Rn concentrations of different subsurface waters in order to assess how important these waters were in contributing lateral inflow to the stream reach.

  3. Manipulation of charge carrier injection into organic field-effect transistors by self-assembled monolayers of alkanethiols

    NARCIS (Netherlands)

    Asadi, K.; Gholamrezaie, F.; Smits, E.C.P.; Blom, W.M.; Boer, B. de

    2007-01-01

    Charge carrier injection into two semiconducting polymers is investigated in field-effect transistors using gold source and drain electrodes that are modified by self-assembled monolayers of alkanethiols and perfluorinated alkanethiols. The presence of an interfacial dipole associated with the molec

  4. Applicability of slug interference tests under Hanford Site test conditions: Analytical assessment and field test evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Spane, F.A. Jr.

    1992-04-01

    Slug interference testing may be a useful technique for characterizing the hydraulic properties of high conductivity formations where problems associated with disposal of contaminated ground water make pumping tests undesirable. The suitability of the slug interference method for characterizing the unconfined aquifer at the Hanford Site was evaluated in a two-phase investigation. The first phase consisted of an analytical assessment. Slug interference responses were predicted over the range of conditions expected for the aquifer. The effects of partial penetration, delayed-yield and aquifer anisotropy on expected test results were also evaluated and possible analytical corrections are presented. The field test evaluation was conducted at a site with two observation wells and a stress well. Results verified the analytical evaluation and gave reasonable values of hydraulic conductivity and storativity. Test design considerations that optimize the observed response are discussed.

  5. Compensation of the magnetization current induced sextupole error at LHC injection field by short lumped permanent sextupole magnets, incorporated into the end configuration of superconducting dipoles

    CERN Document Server

    Asner, A

    1985-01-01

    Compensation of the magnetization current induced sextupole error at LHC injection field by short lumped permanent sextupole magnets, incorporated into the end configuration of superconducting dipoles

  6. Electric Fields Associated with Deep Injections of 10s to 100s keV Electrons in the Inner Magnetosphere

    Science.gov (United States)

    Califf, S.; Li, X.; Jaynes, A. N.; Zhao, H.; Malaspina, D.

    2015-12-01

    Recent observations by HOPE and MagEIS onboard the Van Allen Probes show frequent penetration of 10s to 100s keV electrons through the slot region and into the inner belt, resulting in an abundant electron population below L=3. The conventional picture is that the source populations of these 10s to 100s keV electrons originate in the plasma sheet and are injected (along with plasma sheet ions) into the inner magnetosphere either through enhancements in the large-scale convection electric field and/or through earthward propagating dipolarization fronts associated with substorms. In such cases the inward radial limit of the injections should coincide with the plasmapause. However, these electron injections often extend inside the plasmasphere, are observed far earthward of the typically accepted "flow-braking" region for dipolarization fronts, and occur at much lower L shells than injections of ions with similar energies. We investigate the electric fields associated with these deep electron injections using data from the Van Allen Probes and THEMIS in order to shed light on the underlying mechanisms that allow them to penetrate so far into the inner magnetosphere.

  7. Geochemical evaluation of CO2 injection and containment in a depleted gas field

    NARCIS (Netherlands)

    Tambach, T.J.; Koenen, M.; Wasch, L.J.; Bergen, F. van

    2015-01-01

    The short- and long-term geochemical impact of CO2 injection into a depleted gas reservoir (DGR) is investigated using reservoir/geochemical modeling with TOUGH2/TOUGHREACT and 1D kinetic diffusion modeling with PHREEQC (caprock/well-cement). Simulations of CO2 injection into the reservoir predict d

  8. Field tests of the mobile robot Sherpa

    Energy Technology Data Exchange (ETDEWEB)

    Beaucourt, P. de; Garrec, P.; Morganti, P. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. des Procedes et Systemes Avances; Trouville, B. [Electricite de France (EDF), 78 - Chatou (France); Lucibello, P.; Nobile, M. [ENEA, Rome (Italy). Direzione Studi

    1995-12-31

    This paper summarizes recent demonstrations of the transport capabilities, inside nuclear buildings, of the six egged robot SHERPA, developed by the CEA (Atomic Energy Commission) robotic team. Results of the tests carried out at Chooz-B and Trino Vercellesse Nuclear Power Plants, respectively in June 1993 and in January 1994, in the framework of the European Community TELEMAN Programme, are presented. (authors). 10 refs., 13 figs.

  9. Collective Protection (ColPro) Field Testing

    Science.gov (United States)

    2011-09-28

    burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing...data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this... meiosis level, as defined by the test item specification. The ppbRAE®-like instruments may have a detection range of 1 to 9,999 mg/m3, accurate within

  10. Hydro-Balanced Stuffing Box field test

    Energy Technology Data Exchange (ETDEWEB)

    Giangiacomo, L.A.

    1999-05-28

    The Hydro-Balanced Stuffing Box is a seal assembly for polished rod pumping installations commonly used in oil and gas pumping well installations to contain produced well fluids. The improved stuffing box was developed and patented by Harold H. Palmour of The Palmour Group of Livingston, TX. The stuffing box is designed to reduce the incidence of seal leakage and to utilize an environmentally safe fluid, so that if there is any leakage, environmental damage is reduced or eliminated. The unit was tested on two wells at the Rocky Mountain Oilfield Testing Center. During the test period, the performance of the stuffing box was measured by monitoring the pressure on the tubing and the inner chamber with a Barton Two-pen recorder. The amount of safe fluid consumed, fluid leakage at the top of the stuffing box, pressure supplied from the nitrogen bottle, ambient temperature, and polish rod temperature was recorded. The stuffing box is capable of providing a better seal between well fluids an d the environment than conventional stuffing boxes. It allows the polished rod to operate cooler and with lubrication, extending the life of the packing elements, and reducing the amount of attention required to prevent leakage.

  11. Single Event Analysis and Fault Injection Techniques Targeting Complex Designs Implemented in Xilinx-Virtex Family Field Programmable Gate Array (FPGA) Devices

    Science.gov (United States)

    Berg, Melanie D.; LaBel, Kenneth; Kim, Hak

    2014-01-01

    An informative session regarding SRAM FPGA basics. Presenting a framework for fault injection techniques applied to Xilinx Field Programmable Gate Arrays (FPGAs). Introduce an overlooked time component that illustrates fault injection is impractical for most real designs as a stand-alone characterization tool. Demonstrate procedures that benefit from fault injection error analysis.

  12. Heat tracer test in an alluvial aquifer: Field experiment and inverse modelling

    Science.gov (United States)

    Klepikova, Maria; Wildemeersch, Samuel; Hermans, Thomas; Jamin, Pierre; Orban, Philippe; Nguyen, Frédéric; Brouyère, Serge; Dassargues, Alain

    2016-09-01

    Using heat as an active tracer for aquifer characterization is a topic of increasing interest. In this study, we investigate the potential of using heat tracer tests for characterization of a shallow alluvial aquifer. A thermal tracer test was conducted in the alluvial aquifer of the Meuse River, Belgium. The tracing experiment consisted in simultaneously injecting heated water and a dye tracer in an injection well and monitoring the evolution of groundwater temperature and tracer concentration in the pumping well and in measurement intervals. To get insights in the 3D characteristics of the heat transport mechanisms, temperature data from a large number of observation wells closely spaced along three transects were used. Temperature breakthrough curves in observation wells are contrasted with what would be expected in an ideal layered aquifer. They reveal strongly unequal lateral and vertical components of the transport mechanisms. The observed complex behavior of the heat plume is explained by the groundwater flow gradient on the site and heterogeneities in the hydraulic conductivity field. Moreover, due to high injection temperatures during the field experiment a temperature-induced fluid density effect on heat transport occurred. By using a flow and heat transport numerical model with variable density coupled with a pilot point approach for inversion of the hydraulic conductivity field, the main preferential flow paths were delineated. The successful application of a field heat tracer test at this site suggests that heat tracer tests is a promising approach to image hydraulic conductivity field. This methodology could be applied in aquifer thermal energy storage (ATES) projects for assessing future efficiency that is strongly linked to the hydraulic conductivity variability in the considered aquifer.

  13. FIELD TEST PROGRAM TO DEVELOP COMPREHENSIVE DESIGN, OPERATING, AND COST DATA FOR MERCURY CONTROL SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Michael D. Durham

    2005-03-17

    Brayton Point Unit 1 was successfully tested for applicability of activated carbon injection as a mercury control technology. Test results from this site have enabled a thorough evaluation of the impacts of future mercury regulations to Brayton Point Unit 1, including performance, estimated cost, and operation data. This unit has variable (29-75%) native mercury removal, thus it was important to understand the impacts of process variables and activated carbon on mercury capture. The team responsible for executing this program included: (1) Plant and PG&E National Energy Group corporate personnel; (2) Electric Power Research Institute (EPRI); (3) United States Department of Energy National Energy Technology Laboratory (DOE/NETL); (4) ADA-ES, Inc.; (5) NORIT Americas, Inc.; (6) Apogee Scientific, Inc.; (7) TRC Environmental Corporation; (8) URS Corporation; (9) Quinapoxet Solutions; (10) Energy and Environmental Strategies (EES); and (11) Reaction Engineering International (REI). The technical support of all of these entities came together to make this program achieve its goals. Overall, the objectives of this field test program were to determine the impact of activated carbon injection on mercury control and balance-of-plant processes on Brayton Point Unit 1. Brayton Point Unit 1 is a 250-MW unit that fires a low-sulfur eastern bituminous coal. Particulate control is achieved by two electrostatic precipitators (ESPs) in series. The full-scale tests were conducted on one-half of the flue gas stream (nominally 125 MW). Mercury control sorbents were injected in between the two ESPs. The residence time from the injection grid to the second ESP was approximately 0.5 seconds. In preparation for the full-scale tests, 12 different sorbents were evaluated in a slipstream of flue gas via a packed-bed field test apparatus for mercury adsorption. Results from these tests were used to determine the five carbon-based sorbents that were tested at full-scale. Conditions of interest

  14. Eos modeling and reservoir simulation study of bakken gas injection improved oil recovery in the elm coulee field, Montana

    Science.gov (United States)

    Pu, Wanli

    The Bakken Formation in the Williston Basin is one of the most productive liquid-rich unconventional plays. The Bakken Formation is divided into three members, and the Middle Bakken Member is the primary target for horizontal wellbore landing and hydraulic fracturing because of its better rock properties. Even with this new technology, the primary recovery factor is believed to be only around 10%. This study is to evaluate various gas injection EOR methods to try to improve on that low recovery factor of 10%. In this study, the Elm Coulee Oil Field in the Williston Basin was selected as the area of interest. Static reservoir models featuring the rock property heterogeneity of the Middle Bakken Member were built, and fluid property models were built based on Bakken reservoir fluid sample PVT data. By employing both compositional model simulation and Todd-Longstaff solvent model simulation methods, miscible gas injections were simulated and the simulations speculated that oil recovery increased by 10% to 20% of OOIP in 30 years. The compositional simulations yielded lower oil recovery compared to the solvent model simulations. Compared to the homogeneous model, the reservoir model featuring rock property heterogeneity in the vertical direction resulted in slightly better oil recovery, but with earlier CO2 break-through and larger CO2 production, suggesting that rock property heterogeneity is an important property for modeling because it has a big effect on the simulation results. Long hydraulic fractures shortened CO2 break-through time greatly and increased CO 2 production. Water-alternating-gas injection schemes and injection-alternating-shut-in schemes can provide more options for gas injection EOR projects, especially for gas production management. Compared to CO2 injection, separator gas injection yielded slightly better oil recovery, meaning separator gas could be a good candidate for gas injection EOR; lean gas generated the worst results. Reservoir

  15. Effect of deep injection on field-scale emissions of 1,3-dichloropropene and chloropicrin from bare soil

    Science.gov (United States)

    Yates, S. R.; Ashworth, D. J.; Zheng, W.; Knuteson, J.; van Wesenbeeck, I. J.

    2016-07-01

    Fumigating soil is important for the production of many high-value vegetable, fruit, and tree crops, but fumigants are toxic pesticides with relatively high volatility, which can lead to significant atmospheric emissions. A field experiment was conducted to measure emissions and subsurface diffusion of a mixture of 1,3-dichloropropene (1,3-D) and chloropicrin after shank injection to bare soil at 61 cm depth (i.e., deep injection). Three on-field methods, the aerodynamic (ADM), integrated horizontal flux (IHF), and theoretical profile shape (TPS) methods, were used to obtain fumigant flux density and cumulative emission values. Two air dispersion models (CALPUFF and ISCST3) were also used to back-calculate the flux density using air concentration measurements surrounding the fumigated field. Emissions were continuously measured for 16 days and the daily peak emission rates for the five methods ranged from 13 to 33 μg m-2 s-1 for 1,3-D and 0.22-3.2 μg m-2 s-1 for chloropicrin. Total 1,3-D mass lost to the atmosphere was approximately 23-41 kg ha-1, or 15-27% of the applied active ingredient and total mass loss of chloropicrin was <2%. Based on the five methods, deep injection reduced total emissions by approximately 2-24% compared to standard fumigation practices where fumigant injection is at 46 cm depth. Given the relatively wide range in emission-reduction percentages, a fumigant diffusion model was used to predict the percentage reduction in emissions by injecting at 61 cm, which yielded a 21% reduction in emissions. Significant reductions in emissions of 1,3-D and chloropicrin are possible by injecting soil fumigants deeper in soil.

  16. HV substation earth grid commissioning using current injection test (CIT method: Worst case scenario determination

    Directory of Open Access Journals (Sweden)

    M. Nassereddine, J. Rizk, M. Nagrial, A. Hellany

    2015-01-01

    Full Text Available The existing of the High Voltage (HV infrastructure creates a unique set of safety circumstances. The earthing system is one of the main elements to mitigate any unsafe conditions. Commissioning the earth grid certifies that the implemented system fulfills to the pertinent necessities. This paper endeavors to present vital information on how to perform the earth grid commissioning of an HV infrastructure. This paper will minutiae the minimum needs to guarantee the test will symbolize the actual fault case that the design was based on. A flow chart diagram is established and presented in this paper, which allows the determination of the most suitable injection route. The results of the case study are discussed, and the results are shown in this paper.

  17. Highly sensitive analysis of nucleic acids using capillary gel electrophoresis with ultraviolet detection based on the combination of matrix field-amplified and head-column field-amplified stacking injection.

    Science.gov (United States)

    Lian, Dong-Sheng; Zhao, Shu-Jin

    2015-01-26

    To develop a highly sensitive method for analyzing nucleic acids using capillary gel electrophoresis with ultraviolet detection (CGE-UV), we combined matrix field-amplified with head-column field-amplified stacking injection (C-FASI) to employ the advantages of two methods. Without diminishing the resolution, a limit of detection of 0.13 ng/ml (signal/noise=3) in a 300,000-fold diluted sample was obtained, the sensitivity is 102,308 times higher than that achieved with normal pressure injection, 3077 times that with normal electrokinetic injection, 154 times that with pressure field-amplified sample stacking injection, and 31 times that with matrix field-amplified stacking injection. After establishing the method, we tested the detection of a φX174-Hae III digest DNA product without purification and with a high ionic strength. At the lowest dilution of 5000-fold, sample at a concentration of 10 ng/ml was enriched and detected. The relative standard deviations for migration time and peak area (n=3) were 0.03-1.15 and 0.72-6.42, respectively. To further validate C-FASI was applicable for real sample, a 400 bp PCR product without purification was directly detected with a limit of detection at the concentration of 6000-fold dilution (signal/noise=3), The relative standard deviations for migration time and peak area (n=6) were 0.44 and 4.8, respectively. These results indicated that C-FASI had good qualitative and quantitative detection abilities and CGE-UV based on C-FASI is easy to perform, practical, highly-sensitive and robust for nucleic acid detection, which makes it a highly valuable tool for genetic diagnostics based on nucleic acid analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Performance analysis in Japanese field test program; Field test data kara no chiiki hatsuden kaiseki hoho

    Energy Technology Data Exchange (ETDEWEB)

    Sugiyama, H.; Kurokawa, K.; Uchida, D. [Tokyo University of Agriculture and Technology, Tokyo (Japan); Otani, K.; Sakuta, K.; Tsuda, I. [Electrotechnical Laboratory, Tsukuba (Japan); Oshiro, T.; Sakamoto, K. [Japan Quality Assurance Organization, Tokyo (Japan)

    1997-11-25

    Power generation characteristics are investigated using data collected in photovoltaic power generation field tests being undertaken by NEDO (New Energy and Industrial Technology Development Organization). The photovoltaic power generation system performance is evaluated by examining loss factors leading to degradation in system performance, with weather conditions such as variation in insolation and air temperature, inverter performance, and shadows cast by surrounding buildings taken into consideration. As the result, it is found that the important loss factors are degradation in module performance due to elevated temperature, drift in the maximum output control, degraded inverter performance due to input power variation, effect of shadows, etc. It is learned that system is greatly affected by degradation in module performance due to increased temperature in summer and by shadows in winter, the two being responsible for the output coefficient dropping to approximately 75% throughout the year. The output coefficient frequency distribution charts for the 75 test sites confirm that the rate is as low as 70-80% at many sites. As for the system operating time, it tends to be longer in West Japan where the annual insolation rate is higher. 3 refs., 10 figs.

  19. Tracer Tests in a Fractured Dolomite: 3. Analysis of Mass Transfer in Single-Well Injection-Withdrawal Tests

    Energy Technology Data Exchange (ETDEWEB)

    Haggerty, R.; Fleming, S.W.; Meigs, L.C.; McKenna, S.A.

    1999-03-04

    We investigated multiple-rate diffusion as a possible explanation for observed behavior in a suite of single-well injection-withdrawal (SWIW) tests conducted in a fractured dolomite. We first investigated the ability of a conventional double-porosity model and a multirate diffusion model to explain the data. This revealed that the multirate diffusion hypothesis/model is most consistent with all available data, and is the only model to date that is capable of matching each of the recovery curves entirely. Second, we studied the sensitivity of the SWIW recovery curves to the distribution of diffusion rate coefficients and other parameters. We concluded that the SWIW test is very sensitive to the distribution of rate coefficients, but is relatively insensitive to other flow and transport parameters such as advective porosity and dispersivity. Third, we examined the significance of the constant double-log late-time slopes ({minus}2. 1 to {minus}2.8), which are present in several data sets. The observed late-time slopes are significantly different than would be predicted by either conventional double-porosity or single-porosity media, and are found to be a distinctive feature of multirate diffusion under SWIW test conditions. Fourth, we found that the estimated distributions of diffusion rate coefficients are very broad, with the distributions spanning a range of at least 3.6 to 5.7 orders of magnitude.

  20. Brahms Mobile Agents: Architecture and Field Tests

    Science.gov (United States)

    Clancey, William J.; Sierhuis, Maarten; Kaskiris, Charis; vanHoof, Ron

    2002-01-01

    We have developed a model-based, distributed architecture that integrates diverse components in a system designed for lunar and planetary surface operations: an astronaut's space suit, cameras, rover/All-Terrain Vehicle (ATV), robotic assistant, other personnel in a local habitat, and a remote mission support team (with time delay). Software processes, called agents, implemented in the Brahms language, run on multiple, mobile platforms. These mobile agents interpret and transform available data to help people and robotic systems coordinate their actions to make operations more safe and efficient. The Brahms-based mobile agent architecture (MAA) uses a novel combination of agent types so the software agents may understand and facilitate communications between people and between system components. A state-of-the-art spoken dialogue interface is integrated with Brahms models, supporting a speech-driven field observation record and rover command system (e.g., return here later and bring this back to the habitat ). This combination of agents, rover, and model-based spoken dialogue interface constitutes a personal assistant. An important aspect of the methodology involves first simulating the entire system in Brahms, then configuring the agents into a run-time system.

  1. Test of QED at critical field strength

    Energy Technology Data Exchange (ETDEWEB)

    Bula, C. [Princeton Univ., NJ (United States)

    1997-01-01

    In a new experiment at the Final Focus Test Beam at SLAC, a low-emittance 46.6 GeV electron beam is brought into collisions with terawatt pulses of 1054 nm or 527 nm wavelength from a Nd:glass laser. Peak laser intensities of 10{sup 18} W/cm{sup 2} have been achieved corresponding to a value of 0.6 for the parameter {eta} = e{epsilon}/m{omega}{sub 0}c. In this case, an electron that crosses the center of the laser pulse has near-unit interaction probability. Results are presented for multiphoton Compton scattering in which an electron interacts with up to four laser photons, in agreement with theoretical calculations.

  2. Role of energy systems in two intermittent field tests in women field hockey players

    NARCIS (Netherlands)

    Lemmink, Koen A. P. M.; Visscher, Susan H.

    2006-01-01

    The energetics of 2 field tests that reflect physical performance in intermittent sports (i.e., the Interval Shuttle Sprint Test [ISST] and the Interval Shuttle Run Test [ISRT]) were examined in 21 women field hockey players. The ISST required the players to perform 10 shuttle sprints starting every

  3. Test-field method for mean-field coefficients with MHD background

    CERN Document Server

    Rheinhardt, M

    2010-01-01

    Aims: The test-field method for computing turbulent transport coefficients from simulations of hydromagnetic flows is extended to the regime with a magnetohydrodynamic (MHD) background. Methods: A generalized set of test equations is derived using both the induction equation and a modified momentum equation. By employing an additional set of auxiliary equations, we derive linear equations describing the response of the system to a set of prescribed test fields. Purely magnetic and MHD backgrounds are emulated by applying an electromotive force in the induction equation analogously to the ponderomotive force in the momentum equation. Both forces are chosen to have Roberts flow-like geometry. Results: Examples with an MHD background are studied where the previously used quasi-kinematic test-field method breaks down. In cases with homogeneous mean fields it is shown that the generalized test-field method produces the same results as the imposed-field method, where the field-aligned component of the actual electr...

  4. Effects of Atomic Coherence and Injected Classical Field on Chaotic Dynamics of Non-degenerate Cascade Two-Photon Lasers

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Based on the cascade two-photon laser dynamic equation derived with the technique of quantum Langevin operators with the considerations of coherently prepared three-level atoms and the classical field injected into the cavity, we numerically study the effects of atomic coherence and classical field on the chaotic dynamics of a two-photon laser. Lyapunov exponent and bifurcation diagram calculations show that the Lorenz chaos and hyperchaos can be induced or inhibited by the atomic coherence and the classical field via crisis or Hopf bifurcations.

  5. A Study of Production/Injection Data from Slim Holes and Large-Diameter Wells at the Okuaizu Geothermal Field, Tohoku, Japan

    Energy Technology Data Exchange (ETDEWEB)

    Renner, Joel Lawrence; Garg, Sabodh K.; Combs, Jim

    2002-06-01

    Discharge from the Okuaizu boreholes is accompanied by in situ boiling. Analysis of cold-water injection and discharge data from the Okuaizu boreholes indicates that the two-phase productivity index is about an order of magnitude smaller than the injectivity index. The latter conclusion is in agreement with analyses of similar data from Oguni, Sumikawa, and Kirishima geothermal fields. A wellbore simulator was used to examine the effect of borehole diameter on the discharge capacity of geothermal boreholes with two-phase feedzones. Based on these analyses, it appears that it should be possible to deduce the discharge characteristics of largediameter wells using test data from slim holes with two-phase feeds.

  6. Toward a model for field-testing patient decision-support technologies : a qualitative field-testing study

    NARCIS (Netherlands)

    Evans, R.; Elwyn, G.; Edwards, A.; Watson, E.; Austoker, J.; Grol, R.P.T.M.

    2007-01-01

    BACKGROUND: Field-testing is a quality assurance criterion in the development of patient decision-support technologies (PDSTs), as identified in the consensus statement of the International Patient Decision Aids Standards Collaboration. We incorporated field-testing into the development of a Web-bas

  7. Corrective Action Investigation plan for Corrective Action Unit 546: Injection Well and Surface Releases, Nevada Test Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Alfred Wickline

    2008-03-01

    Corrective Action Unit (CAU) 546 is located in Areas 6 and 9 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 546 is comprised of two Corrective Action Sites (CASs) listed below: •06-23-02, U-6a/Russet Testing Area •09-20-01, Injection Well These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation (CAI) before evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on November 8, 2007, by representatives of the Nevada Division of Environmental Protection and U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process has been used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 546.

  8. Effects of intramuscular injection of glycopyrrolate on Schirmer tear test I results in dogs.

    Science.gov (United States)

    Doering, Clinton J; Lukasik, Victoria M; Merideth, Reuben E

    2016-06-01

    OBJECTIVE To determine effects of glycopyrrolate administered IM on Schirmer tear test I (STT I) measurements in dogs. DESIGN Prospective clinical study. ANIMALS 13 client- and staff-owned dogs. PROCEDURES For both eyes of each dog, STT I measurements were recorded twice 20 minutes apart (at T1 and T2) and 2 to 4 hours later (at T3). Glycopyrrolate (0.01 mg/kg [0.005 mg/lb]) was administered IM to all dogs (3 dogs received an injection of saline [0.9% NaCl] solution on an earlier occasion), and final STT I measurements were recorded 20 minutes later (at T4). Intraocular pressures, heart rate, and respiratory rate were also recorded at each time point. RESULTS Ophthalmic variables did not differ between right and left eyes. In all dogs, variables at T1, T2, or T3 (measurements before glycopyrrolate administration) did not differ; baseline values were therefore defined at T3. At T4, STT I measurements were significantly decreased (mean ± SD decrease, 67.4 ± 15.4% [mean actual decrease, 15.8 mm/min]). During the same period, mean heart rate increased by 26.5 ± 12.0% (mean actual increase, 30.2 beats/min). Glycopyrrolate had no effect on intraocular pressure or respiratory rate. In 5 dogs at 24 hours after glycopyrrolate treatment, STT I measurement in each eye had returned to baseline value. Saline solution treatment (3 dogs) had no effect on any variables. CONCLUSIONS AND CLINICAL RELEVANCE In dogs, IM injection of glycopyrrolate resulted in a clinically relevant transient decrease in aqueous tear production. Application of lacrimomimetics beginning at the time of or within 20 minutes after glycopyrrolate premedication is recommended until STT I measurements return to baseline.

  9. Single Event Test Methodologies and System Error Rate Analysis for Triple Modular Redundant Field Programmable Gate Arrays

    Science.gov (United States)

    Allen, Gregory; Edmonds, Larry D.; Swift, Gary; Carmichael, Carl; Tseng, Chen Wei; Heldt, Kevin; Anderson, Scott Arlo; Coe, Michael

    2010-01-01

    We present a test methodology for estimating system error rates of Field Programmable Gate Arrays (FPGAs) mitigated with Triple Modular Redundancy (TMR). The test methodology is founded in a mathematical model, which is also presented. Accelerator data from 90 nm Xilins Military/Aerospace grade FPGA are shown to fit the model. Fault injection (FI) results are discussed and related to the test data. Design implementation and the corresponding impact of multiple bit upset (MBU) are also discussed.

  10. ROPS performance during field upset and static testing.

    Science.gov (United States)

    Harris, J R; McKenzie, E A; Etherton, J R; Cantis, D M; Ronaghi, M

    2010-01-01

    Agriculture remains one of the most hazardous occupations in the U.S. By conservative estimates, tractor overturns alone claim 120 lives annually. A rollover protective structure (ROPS) and a seatbelt are a highly effective engineering safety control that can prevent many of these fatalities and reduce the severity of injuries associated with tractor overturn. SAE J2194 is a consensus performance standard established for agricultural ROPS. According to this standard, satisfactory ROPS performance can be demonstrated through static testing, field upset testing, or impact testing. A previous modeling study suggested that static testing may underpredict the strain induced in a ROPS during afield upset. In the current study, field upset testing and laboratory static testing results were compared. Field upset testing included six rear and six side upset tests performed according to SAE J2194 guidelines. Additionally, static testing was performed on a ROPS of the same model. The results support findings from the modeling study. Near the lowest sections of the ROPS, the plastic strain resulting from rear upset testing exceeded the plastic strain from static testing for 18 of 24 data points. Conversely, the ROPS plastic strain from side upset testing was typically less than plastic strain from laboratory static testing. However, data indicate that the side upset test may not be very repeatable. This study suggests that the longitudinal loading energy criterion for static testing might not be a conservative predictor of rear upset ROPS response.

  11. Media-fill simulation tests in manual and robotic aseptic preparation of injection solutions in syringes.

    Science.gov (United States)

    Krämer, Irene; Federici, Matteo; Kaiser, Vanessa; Thiesen, Judith

    2016-04-01

    The purpose of this study was to evaluate the contamination rate of media-fill products either prepared automated with a robotic system (APOTECAchemo™) or prepared manually at cytotoxic workbenches in the same cleanroom environment and by experienced operators. Media fills were completed by microbiological environmental control in the critical zones and used to validate the cleaning and disinfection procedures of the robotic system. The aseptic preparation of patient individual ready-to-use injection solutions was simulated by using double concentrated tryptic soy broth as growth medium, water for injection and plastic syringes as primary packaging materials. Media fills were either prepared automated (500 units) in the robot or manually (500 units) in cytotoxic workbenches in the same cleanroom over a period of 18 working days. The test solutions were incubated at room temperature (22℃) over 4 weeks. Products were visually inspected for turbidity after a 2-week and 4-week period. Following incubation, growth promotion tests were performed with Staphylococcus epidermidis. During the media-fill procedures, passive air monitoring was performed with settle plates and surface monitoring with contact plates on predefined locations as well as fingerprints. The plates got incubated for 5-7 days at room temperature, followed by 2-3 days at 30-35℃ and the colony forming units (cfu) counted after both periods. The robot was cleaned and disinfected according to the established standard operating procedure on two working days prior to the media-fill session, while on six other working days only six critical components were sanitized at the end of the media-fill sessions. Every day UV irradiation was operated for 4 h after finishing work. None of the 1000 media-fill products prepared in the two different settings showed turbidity after the incubation period thereby indicating no contamination with microorganisms. All products remained uniform, clear, and light

  12. Hydrogeological characterization of shallow-depth zone for CO2 injection and leak test at a CO2 environmental monitoring site in Korea

    Science.gov (United States)

    Lee, S. S.; Kim, T. W.; Kim, H. H.; Ha, S. W.; Jeon, W. T.; Lee, K. K.

    2015-12-01

    The main goal of the this study is to evaluate the importance of heterogeneities in controlling the field-scale transport of CO2 are originated from the CO2 injected at saturated zone below the water table for monitoring and prediction of CO2 leakage from a reservoir. Hydrogeological and geophysical data are collected to characterize the site, prior to conducting CO2 injection experiment at the CO2 environmental monitoring site at Eumseong, Korea. The geophysical data were acquired from borehole electromagnetic flowmeter tests, while the hydraulic data were obtained from pumping tests, slug tests, and falling head permeability tests. Total of 13 wells to perform hydraulic and geophysical test are established along groundwater flow direction in regular sequence, revealed by the results of borehole electromagnetic flowmeter test. The results of geophysical tests indicated that hydraulic gradient is not identical with the topographic gradient. Groundwater flows toward the uphill direction in the study area. Then, the hydraulic tests were conducted to identify the hydraulic properties of the study site. According to the results of pumping and slug tests at the study site, the hydraulic conductivity values show ranges between 4.75 x 10-5 cm/day and 9.74 x 10-5 cm/day. In addition, a portable multi-level sampling and monitoring packer device which remains inflated condition for a long period developed and used to isolate designated depths to identify vertical distribution of hydrogeological characteristics. Hydrogeological information obtained from this study will be used to decide the injection test interval of CO2-infused water and gaseous CO2. Acknowledgement: Financial support was provided by "R&D Project on Environmental Mangement of Geologic CO2 Storage" from the KEITI (Project Number: 2014001810003).

  13. Could sperm aneuploidy rate determination be used as a predictive test before intracytoplasmic sperm injection?

    Science.gov (United States)

    Petit, François M; Frydman, Nelly; Benkhalifa, Moncef; Le Du, Anne; Aboura, Azzedine; Fanchin, Renato; Frydman, Rene; Tachdjian, Gerard

    2005-01-01

    Chromosome abnormalities in embryos are a major cause of implantation and development failures. Some couples with normal karyotypes have repeated implantation failures after intracytoplasmic sperm injection (ICSI). In order to value patients at risk for genetic ICSI failures and the validity of sperm aneuploidy analysis, we have studied cytogenetic abnormalities in sperm from ICSI patients. Twenty-nine patients with normal karyotypes were included. Ten patients had at least 4 ICSI treatments without pregnancy (group A). Nine patients had a pregnancy after 1 to 3 ICSI treatments (group B). Ten fertile men with normal semen parameters were studied as controls (group C). Fluorescent in situ hybridization (FISH) was used for sperm nucleus cytogenetic analysis using chromosomes 8, 9, 13, 18, 21, X, and Y specific probes. Aneuploidy for each chromosome and diploidy rates were significantly higher in group A than in group B and in group B than in group C (P < .05). Considering each patient in groups A and B, aneuploidy rate for each chromosome was too variable to be considered as a significant test. We proposed analysis of the total sperm aneuploidy. Chromosomal sperm nuclei profile could be used as a predictive biological test before ICSI in order to improve genetic counseling for oligoasthenoteratozoospermia patients.

  14. Probe Station and Near-Field Scanner for Testing Antennas

    Science.gov (United States)

    Zaman, Afroz; Lee, Richard Q.; Darby, William G.; Barr, Philip J.; Miranda, Felix A.; Lambert, Kevin

    2006-01-01

    A facility that includes a probe station and a scanning open-ended waveguide probe for measuring near electromagnetic fields has been added to Glenn Research Center's suite of antenna-testing facilities, at a small fraction of the cost of the other facilities. This facility is designed specifically for nondestructive characterization of the radiation patterns of miniaturized microwave antennas fabricated on semiconductor and dielectric wafer substrates, including active antennas that are difficult to test in traditional antenna-testing ranges because of fragility, smallness, or severity of DC-bias or test-fixture requirements. By virtue of the simple fact that a greater fraction of radiated power can be captured in a near-field measurement than in a conventional far-field measurement, this near-field facility is convenient for testing miniaturized antennas with low gains.

  15. Fault injection as a test method for an FPGA in charge of data readout for a large tracking detector

    CERN Document Server

    Roed, K; Richter, M; Fehlker, D; Helstrup, H; Alme, J; Ullaland, K

    2011-01-01

    This paper describes how fault injection has been implemented as a test method for an FPGA in an existing hardware configuration setup. As this FPGA is in charge of data readout for a large tracking detector, the reliability of this FPGA is of high importance. Due to the complexity of the readout electronics, irradiation testing is technically difficult at this stage of the system commissioning. The work presented in this paper is therefore motivated by introducing fault injection as an alternative method to characterize failures caused by SEUs. It is a method to study the effect that a configuration upset may have on the operation of the FPGA. The target platform consists of two independent modules for data acquisition and detector control functionality. Fault injection to test the response of the data acquisition module is made possible by implementing the solution as part of the detector control functionality. Correct implementation is validated by a simple shift register design. Our results demonstrate th...

  16. Characterizing the potential for fault reactivation related to CO2 injection through subsurface structural mapping and stress field analysis, Wellington Field, Sumner County, KS

    Science.gov (United States)

    Schwab, D.; Bidgoli, T.; Taylor, M. H.

    2015-12-01

    South-central Kansas has experienced an unprecedented increase in seismic activity since 2013. The spatial and temporal relationship of the seismicity with brine disposal operations has renewed interest in the role of fluids in fault reactivation. This study focuses on determining the suitability of CO2 injection into a Cambro-Ordovician reservoir for long-term storage and a Mississippian reservoir for enhanced oil recovery in Wellington Field, Sumner County, Kansas. Our approach for determining the potential for induced seismicity has been to (1) map subsurface faults and estimate in-situ stresses, (2) perform slip and dilation tendency analysis to identify optimally-oriented faults relative to the estimated stress field, and (3) monitor surface deformation through cGPS data and InSAR imaging. Through the use of 3D seismic reflection data, 60 near vertical, NNE-striking faults have been identified. The faults range in length from 140-410 m and have vertical separations of 3-32m. A number of faults appear to be restricted to shallow intervals, while others clearly cut the top basement reflector. Drilling-induced tensile fractures (N=78) identified from image logs and inversion of earthquake focal mechanism solutions (N=54) are consistent with the maximum horizontal stress (SHmax) oriented ~E-W. Both strike-slip and normal-slip fault plane solutions for earthquakes near the study area suggest that SHmax and Sv may be similar in magnitude. Estimates of stress magnitudes using step rate tests (Shmin = 2666 psi), density logs (Sv = 5308 psi), and calculations from wells with drilling induced tensile fractures (SHmax = 4547-6655 psi) are determined at the gauge depth of 4869ft. Preliminary slip and dilation tendency analysis indicates that faults striking 0°-20° are stable, whereas faults striking 26°-44° may have a moderate risk for reactivation with increasing pore-fluid pressure.

  17. CO2 and H2S gas injection heavy oil field

    Energy Technology Data Exchange (ETDEWEB)

    Padua, K.G.O. [Petrobras (Canada)

    2011-07-01

    Heavy oils constitute one of the largest fossil fuel reserves on earth; among them there are naturally fractured carbonate reservoirs under bottomwater. Those reservoirs are composed of sour heavy oil and its recovery is difficult, miscible processes are expensive and thermal methods are inefficient due to the harsh conditions. The aim of this paper is to investigate the use of injection of carbon dioxide and hydrogen sulfide mixtures. Fluid and reservoir characterizations were conducted using published observations, dynamic modeling and a comparative study. Reservoir performance under natural depletion and immiscible gas injection with effluent gas were then analyzed and compared. Expected breakthrough and composition of the produced fluid were presented in this study to provide the input necessary for operational planning. This paper presented a comparison between reservoir performance under natural depletion and immiscible gas injection, providing qualitative information to evaluate an effluent gas project.

  18. Theoretical aspects for estimating anisotropic saturated hydraulic conductivity from in-well or direct-push probe injection tests in uniform media

    Science.gov (United States)

    Klammler, Harald; Layton, Leif; Nemer, Bassel; Hatfield, Kirk; Mohseni, Ana

    2017-06-01

    Hydraulic conductivity and its anisotropy are fundamental aquifer properties for groundwater flow and transport modeling. Current in-well or direct-push field measurement techniques allow for relatively quick determination of general conductivity profiles with depth. However, capabilities for identifying local scale conductivities in the horizontal and vertical directions are very limited. Here, we develop the theoretical basis for estimating horizontal and vertical conductivities from different types of steady-state single-well/probe injection tests under saturated conditions and in the absence of a well skin. We explore existing solutions and a recent semi-analytical solution approach to the flow problem under the assumption that the aquifer is locally homogeneous. The methods are based on the collection of an additional piece of information in the form of a second injection (or recirculation) test at a same location, or in the form of an additional head or flow observation along the well/probe. Results are represented in dimensionless charts for partial validation against approximate solutions and for practical application to test interpretation. The charts further allow for optimization of a test configuration to maximize sensitivity to anisotropy ratio. The two methods most sensitive to anisotropy are found to be (1) subsequent injection from a lateral screen and from the bottom of an otherwise cased borehole, and (2) single injection from a lateral screen with an additional head observation along the casing. Results may also be relevant for attributing consistent divergences in conductivity measurements from different testing methods applied at a same site or location to the potential effects of anisotropy. Some practical aspects are discussed and references are made to existing methods, which appear easily compatible with the proposed procedures.

  19. Matched injection in a helical undulator taking into account the orbit amplitude and the longitudinal magnetic field

    Science.gov (United States)

    Papadichev, V. A.

    2002-05-01

    Helical undulators are widely used in FELs because they are inexpensive and easy to fabricate. Also, because field amplitudes can be conveniently adjusted with high accuracy. Their main weakness is their use of adiabatic input and output (up to 10 periods each) for matched injection (ejection) of the electron beam in the undulator field. This leads to considerable lengthening of the undulator and optical resonator, without simultaneously providing, in a number of cases, the required injection accuracy (due to some angle error and failure to account for orbit amplitude). Here alternative methods of matched injection are described that take into account orbit amplitude and external magnetic field. The length of correcting elements does not exceed one-half of the undulator period. When the overall length of the helical undulator is large, their application permits its realization in the form of a set of successive sections with free straight gaps in which devices can be placed for measuring beam parameters and correction of the trajectory.

  20. [A literature analysis of power frequency electric field testing data].

    Science.gov (United States)

    Zhang, Suli; Guo, Zehua; Yu, Xintian; Ding, Yan; Zhu, Zhiliang

    2015-06-01

    To analyze the literature on power frequency electric field testing data and to propose views and suggestions for current testing. The literature on power frequency electric field testing data published in the previous years was searched to identify 306 articles involving 193 valid testing data. Mann-Whitney test and Wilcoxon W test were used for analyzing the testing data. The classification of data was carried out according to one quarter of occupational exposure limit (1.25 kV/m), one half of the exposure limit (2.5 kV/m), and the exposure limit (5 kV/m). The structure of testing data showed a significant difference between the non-power facility group and the power facility group (Pelectric field is extensive. However, the power frequency electric field testing data in actual workplaces except high-voltage power facilities are far less than the occupational exposure limit with little harmfulness. There is a phenomenon of excessive testing at present.

  1. Field-based physiological testing of wheelchair athletes.

    Science.gov (United States)

    Goosey-Tolfrey, Victoria L; Leicht, Christof A

    2013-02-01

    The volume of literature on field-based physiological testing of wheelchair sports, such as basketball, rugby and tennis, is considerably smaller when compared with that available for individuals and team athletes in able-bodied (AB) sports. In analogy to the AB literature, it is recognized that performance in wheelchair sports not only relies on fitness, but also sport-specific skills, experience and technical proficiency. However, in contrast to AB sports, two major components contribute towards 'wheeled sports' performance, which are the athlete and the wheelchair. It is the interaction of these two that enable wheelchair propulsion and the sporting movements required within a given sport. Like any other athlete, participants of wheelchair sports are looking for efficient ways to train and/or analyse their technique and fitness to improve their performance. Consequently, laboratory and/or field-based physiological monitoring tools used at regular intervals at key time points throughout the year must be considered to help with training evaluation. The present review examines methods available in the literature to assess wheelchair sports fitness in a field-based environment, with special attention on outcome variables, validity and reliability issues, and non-physiological influences on performance. It also lays out the context of field-based testing by providing details about the Paralympic court sports and the impacts of a disability on sporting performance. Due to the limited availability of specialized equipment for testing wheelchair-dependent participants in the laboratory, the adoption of field-based testing has become the preferred option by team coaches of wheelchair athletes. An obvious advantage of field-based testing is that large groups of athletes can be tested in less time. Furthermore, athletes are tested in their natural environment (using their normal sports wheelchair set-up and floor surface), potentially making the results of such testing

  2. Field Testing Research at the NWTC (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2015-02-01

    The National Wind Technology Center (NWTC) at the National Renewable Laboratory (NREL) has extensive field testing capabilities that have been used in collaboration with the wind industry to accelerate wind technology development and deployment for more than 30 years.

  3. Validation of precision powder injection molding process simulations using a spiral test geometry

    DEFF Research Database (Denmark)

    Marhöfer, Maximilian; Müller, Tobias; Tosello, Guido

    2015-01-01

    Like in many other areas of engineering, process simulations find application in precision injection molding to assist and optimize the quality and design of precise products and the molding process. Injection molding comprises mainly the manufacturing of plastic components. However, the variant ...

  4. Field tests and commercialization of natural gas leak detectors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, D.S.; Jeon, J.S.; Kim, K.D.; Cho, Y.A. [R and D Center, Korea Gas Corporation, Ansan (Korea)

    1999-09-01

    Objectives - (1) fields test of industrial gas leak detection monitoring system. (2) commericialization of residential gas leak detector. Contents - (1) five sets of gas leak detection monitoring system were installed at natural gas transmition facilities and tested long term stability and their performance. (2) improved residential gas leak detector was commercialised. Expected benefits and application fields - (1) contribution to the improvement of domestic gas sensor technology. (2) localization of fabrication technology for gas leak detectors. 23 refs., 126 figs., 37 tabs.

  5. Effects of injection speed of test samples on the mouse bioassay for paralytic shellfish poisoning toxins

    Directory of Open Access Journals (Sweden)

    Hodaka Suzuki

    2013-06-01

    Full Text Available The mouse bioassay has been used as the official method for paralytic shellfish poisoning toxins detection in Japan since 1980. However, differences in the results of this assay, when performed by different investigators, have been noted despite the use of the same sample. This study was performed to examine the effect of the injection speed, a hypothetical cause of such differences, on the death time of mice. Speed-controlled injection of the toxin (at 12, 6, 3, and 1.5 mL/min into mice was performed using a syringe pump, and the death times of mice were measured. No statistically significant differences were found among the groups, even between fast injection (5 s and very slow injection (40 s, indicating that the injection speed may not be the crucial factor for this assay.

  6. Testing of a one dimensional model for Field II calibration

    DEFF Research Database (Denmark)

    Bæk, David; Jensen, Jørgen Arendt; Willatzen, Morten

    2008-01-01

    to the calibrated Field II program for 1, 4, and 10 cycle excitations. Two parameter sets were applied for modeling, one real valued Pz27 parameter set, manufacturer supplied, and one complex valued parameter set found in literature, Alguer´o et al. [11]. The latter implicitly accounts for attenuation. Results show......Field II is a program for simulating ultrasound transducer fields. It is capable of calculating the emitted and pulse-echoed fields for both pulsed and continuous wave transducers. To make it fully calibrated a model of the transducer’s electro-mechanical impulse response must be included. We...... examine an adapted one dimensional transducer model originally proposed by Willatzen [9] to calibrate Field II. This model is modified to calculate the required impulse responses needed by Field II for a calibrated field pressure and external circuit current calculation. The testing has been performed...

  7. Status of a study of the thermal regime of Uzen field and the effect of cold water injection in pattern flooding on the development of and oil production from the pay zones

    Energy Technology Data Exchange (ETDEWEB)

    Utebaev, S.U.; Smolnikov, N.V.; Yuferov, Yu.K.; Teslyuk, E.V.; Ilyaev, V.I.

    1968-11-01

    The crude oil in the Uzen field contains up to 26% paraffin, and paraffin deposition begins at +62/sup 0/ + 3/sup 0/C. Massive paraffin deposition occurs at 45/sup 0/ to 50/sup 0/C, and at 30/sup 0/C the oil congeals. Reservoir temperature is 65/sup 0/C. Because reservoir temperature is close to paraffin deposition temperature, great concern was felt in injecting cold water into the reservoir. A test program was conducted to determine the effect of cold water (15/sup 0/ to 25/sup 0/C) injection on reservoir behavior. This study showed that: (1) cold water rapidly lowered bottom-hole temperature in 1,400 m wells from 65/sup 0/ to 20/sup 0/C; (2) after cold water injection was stopped, bottom-hole temperature increased slowly; (3) the cold water decreased reservoir temperature in an observation well, 115 m distant from the water injection well; and (4) the cold water did not reduce the water intake rates of injection wells. These observations are backed by geophysical data. Plans are in progress to test hot water (100/sup 0/C) injection at this field.

  8. High Speed Fault Injection Tool Implemented With Verilog HDL on FPGA for Testing Fault Tolerance Designs

    Directory of Open Access Journals (Sweden)

    G. Gopinath Reddy

    2013-11-01

    Full Text Available This paper presents an FPGA-based fault injection tool, called FITO that supports several synthesizable fault models for dependability analysis of digital systems modeled by Verilog HDL. Using the FITO, experiments can be performed in real-time with good controllability and observability. As a case study, an Open RISC 1200 microprocessor was evaluated using an FPGA circuit. About 4000 permanent, transient, and SEUfaults were injected into this microprocessor. The results show that the FITO tool is more than 79 times faster than a pure simulation-based fault injection with only 2.5% FPGA area overhead.

  9. Contrast sensivity in test field with bright surround.

    NARCIS (Netherlands)

    Schreuder, D.A.

    1965-01-01

    A set of curves and two empirical formulas have been derived which represent the contrast sensivity of the human eye when both the test-object and the test-field luminance are considerable lower than the adaption level. Although derived to be used for the lighting of traffic tunnels, the data may be

  10. Field testing of high-efficiency supermarket refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Walker, D. (Foster-Miller, Inc., Waltham, MA (United States))

    1992-12-01

    The Electric Power Research Institute (EPRI) has undertaken a field test to quantify the performance of high-efficiency supermarket refrigeration. The initial work on this project was presented in EPRI report CU-6268 Supermarket Refrigeration Modeling and Field Demonstration.'' The information given here was generated through continued testing at the field test site. The field test was conducted at a supermarket owned by Safeway Stores, Inc., that was located in Menlo Park, CA. Testing was performed with the existing conventional refrigeration system and a high-efficiency multiplex refrigeration system that was installed for these tests. The results of the testing showed that the high-efficiency multiplex system reduced refrigeration energy consumption by 23.9% and peak electric demand for refrigeration by 30.0%. Analyses of these savings showed that the largest portion was due to the use of high-efficiency compressors (29.5% of total saving). Floating head pressure control, ambient and mechanical subcooling, compressor multiplexing and hot gas defrost accounted for 50% of total savings. The remainder of the savings (20.5%) were attributed to the use of an evaporative condenser. Tests were also conducted with several retrofit technologies. The most promising results were obtained with external liquid-suction heat exchangers installed at the outlets of the display cases. Favorable paybacks were calculated for these exchangers when they were used with very low and low temperature refrigeration.

  11. Differential Gender Performance on the Major Field Test-Business

    Science.gov (United States)

    Bielinska-Kwapisz, Agnieszka; Brown, F. William

    2013-01-01

    The Major Field Test in Business (MFT-B), a standardized assessment test of business knowledge among undergraduate business seniors, is widely used to measure student achievement. Many previous studies analyzing scores on the MFT-B report gender differences on the exam even after controlling for student's aptitude, general intellectual ability,…

  12. "Second order" exploratory data analysis of the large scale gas injection test (lasgit) dataset, focused around known gas migration events

    NARCIS (Netherlands)

    Bennett, D.; Cuss, R.; Vardon, P.J.; Harrington, J.; Sedighi, M.; Shaw, R.; Thomas, H.

    2013-01-01

    Within large-scale experimental datasets a wealth of small scale information can typically be found. An example of such an experiment is the Large Scale Gas Injection Test (Lasgit). A toolkit has been developed to facilitate the investigation of the small scale or ‘second order’ detail contained wit

  13. Effects of Hot Steam Injection from the Slot at the Trailing Edge on Turbine Nozzle Vane Flow Field

    Institute of Scientific and Technical Information of China (English)

    Liang Xu; Peigang Yan; Hongyan Huang; Wanjin Han

    2008-01-01

    Moisture removal slot configurations with three different opening widths are in turn set at the trailing edges of a turbine hollow guide vane. The flow fields are analyzed by two-phase flow numerical simulation of solving the steady three dimensional Reynolds averaged Navier-Stokes equations on the basis of the real water vapor thermo-physical properties, and the blade temperature field is solved by the fluid-solid coupling. Exergy parame-ter is introduced as a measure to evaluate the economic cost of energy conversion process. The results indicate that the bigger slot allow lower quality of hot steam in the case of the equivalent injected quantity, while it has a higher exergy effective efficiency of the mixing process in the cascade channels. The hot steam injecting at the trailing edges has an optimal injected mass flow rate for a relatively large slot, on this point the exergy effective efficiency is the maximum, namely the flow loss is the minimum.

  14. HOW AUTOMATED TESTING TOOLS ARE SHOWING ITS IMPACT IN THE FIELD OF SOFTWARE TESTING

    Directory of Open Access Journals (Sweden)

    Deepti Gaur

    2012-09-01

    Full Text Available As, we know that Software testing is a very vast field inSoftware development life cycle. In this paper, we describethat how automated testing tools are very much convenientand easy to use which also makes testing faster and moreeffective in less time. Actually the world of technologyrevolves at fast pace today and among all Testing tools onlyautomated testing tools makes Software testing moresignificant and effective.

  15. Automated particulate sampler field test model operations guide

    Energy Technology Data Exchange (ETDEWEB)

    Bowyer, S.M.; Miley, H.S.

    1996-10-01

    The Automated Particulate Sampler Field Test Model Operations Guide is a collection of documents which provides a complete picture of the Automated Particulate Sampler (APS) and the Field Test in which it was evaluated. The Pacific Northwest National Laboratory (PNNL) Automated Particulate Sampler was developed for the purpose of radionuclide particulate monitoring for use under the Comprehensive Test Ban Treaty (CTBT). Its design was directed by anticipated requirements of small size, low power consumption, low noise level, fully automatic operation, and most predominantly the sensitivity requirements of the Conference on Disarmament Working Paper 224 (CDWP224). This guide is intended to serve as both a reference document for the APS and to provide detailed instructions on how to operate the sampler. This document provides a complete description of the APS Field Test Model and all the activity related to its evaluation and progression.

  16. Scaleup tests and supporting research for the development of duct injection technology. Topical report No. 2, Task 3.1: Evaluation of system performance, Duct Injection Test Facility, Muskingum River Power Plant, Beverly, Ohio

    Energy Technology Data Exchange (ETDEWEB)

    Felix, L.G.; Dismukes, E.B.; Gooch, J.P. [Southern Research Inst., Birmingham, AL (United States); Klett, M.G.; Demian, A.G. [Gilbert/Commonwealth, Inc., Reading, PA (United States)

    1992-04-20

    This Topical Report No. 2 is an interim report on the Duct Injection Test Facility being operated for the Department of Energy at Beverly, Ohio. Either dry calcium hydroxide or an aqueous slurry of calcium hydroxide (prepared by slaking quicklime) is injected into a slipstream of flue gas to achieve partial removal of SO{sub 2} from a coal-burning power station. Water injected with the slurry or injected separately from the dry sorbents cools the flue gas and increases the water vapor content of the gas. The addition of water, either in the slurry or in a separate spray, makes the extent of reaction between the sorbent and the SO{sub 2} more complete; the presumption is that water is effective in the liquid state, when it is able to wet the sorbent particles physically, and not especially effective in the vapor state. An electrostatic precipitator collects the combination of suspended solids (fly ash from the boiler and sorbent from the duct injection process). All of the operations are being carried out on the scale of approximately 50,000 acfm of flue gas.

  17. Heat tracer test in an alluvial aquifer: field experiment and inverse modelling

    Science.gov (United States)

    Klepikova, Maria; Wildemeersch, Samuel; Jamin, Pierre; Orban, Philippe; Hermans, Thomas; Nguyen, Frederic; Brouyère, Serge; Dassargues, Alain

    2016-04-01

    Using heat as an active tracer for aquifer characterization is a topic of increasing interest. In this study, we investigate the potential of using heat tracer tests for characterization of a shallow alluvial aquifer. A thermal tracer test was conducted in the alluvial aquifer of the Meuse River, Belgium. The tracing experiment consisted in simultaneously injecting heated water and a dye tracer in a piezometer and monitoring the evolution of groundwater temperature and tracer concentration in the recovery well and in monitoring wells. To get insights in the 3D characteristics of the heat transport mechanisms, temperature data from a large number of observation wells distributed throughout the field site (space-filling arrangement) were used. Temperature breakthrough curves in observation wells are contrasted with what would be expected in an ideal layered aquifer. They reveal strongly unequal lateral and vertical components of the transport mechanisms. The observed complex behavior of the heat plume was explained by the groundwater flow gradient on the site and heterogeneity of hydraulic conductivity field. Moreover, due to high injection temperatures during the field experiment a temperature-induced fluid density effect on heat transport occurred. By using a flow and heat transport numerical model with variable density coupled with the pilot point inverse approach, main preferential flow paths were delineated.

  18. Experiment data report for Semiscale Mod-1 tests S-05-2A and S-05-2B (alternate ECC injection tests)

    Energy Technology Data Exchange (ETDEWEB)

    Patton, Jr., M. L.; Collins, B. L.; Sackett, K. E.

    1977-04-01

    Recorded test data are presented for Tests S-05-2A and S-05-2B of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Tests S-05-2A and S-05-2B were conducted from initial conditions of 2263 psia and 543/sup 0/F and 2272 psia and 542/sup 0/F, respectively, to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the tests, cooling water was injected into the intact loop pump suction and broken loop cold leg to simulate emergency core coolant injection in a PWR with flow rates based on system volume scaling. For Test S-05-2A the intact loop pump speed was held constant throughout the test at the initial blowdown value. During Test S-05-2B the pump speed was reduced and stopped according to a predetermined coastdown schedule.

  19. Test Results of the AC Field Measurements of Fermilab Booster Corrector Magnets

    Energy Technology Data Exchange (ETDEWEB)

    DiMarco, E.Joseph; Harding, D.J.; Kashikhin, V.S.; Kotelnikov, S.K.; Lamm, M.J.; Makulski, A.; Nehring, R.; Orris, D.F.; Schlabach, P.; Sylvester, C.; Tartaglia, Michael Albert; /Fermilab

    2008-06-25

    Multi-element corrector magnets are being produced at Fermilab that enable correction of orbits and tunes through the entire cycle of the Booster, not just at injection. The corrector package includes six different corrector elements--normal and skew orientations of dipole, quadrupole, and sextupole--each independently powered. The magnets have been tested during typical AC ramping cycles at 15Hz using a fixed coil system to measure the dynamic field strength and field quality. The fixed coil is comprised of an array of inductive pick-up coils around the perimeter of a cylinder which are sampled simultaneously at 100 kHz with 24-bit ADC's. The performance of the measurement system and a summary of the field results are presented and discussed.

  20. Applications of advanced petroleum production technology and water alternating gas injection for enhanced oil recovery: Mattoon Oil Field, Illinois. Third quarterly report, [July--September 1993

    Energy Technology Data Exchange (ETDEWEB)

    Baroni, M.R.

    1993-12-21

    The objectives of this project are to continue reservoir characterization of the Cypress Sandstone; to identify and map facies-defined waterflood units (FDWS); and to design and implement water-alternating-gas (WAG) oil recovery utilizing carbon dioxide (CO{sub 2}) The producibility problems are permeability variation and poor sweep efficiency. Part 1 of the project focuses on the development of computer-generated geological and reservoir simulation models that will be used to select sites for the demonstration and implementation of CO{sub 2} displacement programs in Part 2. Included in Part 1 is the site selection and drilling of an infill well, coring of the Cypress interval, and injectivity testing to gather information used to update the reservoir simulation model. Part 2 involves field implementation of WAG. Technology Transfer includes outreach activity such as seminars, workshops, and field trips.

  1. Applications of advanced petroleum production technology and water alternating gas injection for enhanced oil recovery: Mattoon Oil Field, Illinois. Fourth quarterly report, [October 1, 1993--December 31, 1993

    Energy Technology Data Exchange (ETDEWEB)

    Baroni, M.

    1994-01-25

    The objectives of this project are to continue reservoir characterization of the Cypress Sandstone; to identify and map fades-defined waterflood units (FDWS); and to design and Implement water-alternating-gas (WAG) oil recovery utilizing carbon dioxide (CO{sub 2}). The producibility problems are permeability variation and poor sweep efficiency. Phase 1 of the project focuses on the development of computer-generated geological and reservoir simulation models that will be used to select sites for the demonstration and implementation of CO{sub 2} displacement programs in Phase 2. Included in Phase 1 is the site selection and drilling of an infill well, coring of the Cypress interval, and injectivity testing to gather information used to update the reservoir simulation model. Phase 2 involves field implementation of WAG. Technology Transfer includes outreach activity such as seminars, workshops, and field trips. Technical progress for this quarter is described.

  2. Applications of advanced petroleum production technology and water alternating gas injection for enhanced oil recovery: Mattoon Oil Field, Illinois. [Quarterly report], January--March 1994

    Energy Technology Data Exchange (ETDEWEB)

    Baroni, M.R.

    1994-04-30

    The objectives of this project are to continue reservoir characterization of the Cypress Sandstone; to identify and map facies-defined waterflood units (FDWS); and to design and implement water-alternating-gas (WAG) oil recovery utilizing carbon dioxide (CO{sub 2}). The producibility problems are permeability variation and poor sweep efficiency. Phase 1 of the project focuses on the development of computer-generated geological and reservoir simulation models that will be used to select sites for the demonstration and implementation of CO{sub 2} displacement programs in Phase 2. Included in Phase 1 is the site selection and drilling of an infill well, coring of the Cypress internal and injectivity testing to gather information used to update the reservoir simulation model. Phase 2 involves field implementation of WAG. Technology Transfer includes outreach activity such as seminars, workshops, and field trips. Accomplishments for the past quarter are described.

  3. Analysis of Tests of Subsurface Injection, Storage, and Recovery of Freshwater in Lancaster, Antelope Valley, California

    Science.gov (United States)

    Phillips, Steven P.; Carlson, Carl S.; Metzger, Loren F.; Howle, James F.; Galloway, Devin L.; Sneed, Michelle; Ikehara, Marti E.; Hudnut, Kenneth W.; King, Nancy E.

    2003-01-01

    Ground-water levels in Lancaster, California, declined more than 200 feet during the 20th century, resulting in reduced ground-water supplies and more than 6 feet of land subsidence. Facing continuing population growth, water managers are seeking solutions to these problems. Injection of imported, treated fresh water into the aquifer system when it is most available and least expensive, for later use during high-demand periods, is being evaluated as part of a management solution. The U.S. Geological Survey, in cooperation with the Los Angeles County Department of Public Works and the Antelope Valley-East Kern Water Agency, monitored a pilot injection program, analyzed the hydraulic and subsidence-related effects of injection, and developed a simulation/optimization model to help evaluate the effectiveness of using existing and proposed wells in an injection program for halting the decline of ground-water levels and avoiding future land subsidence while meeting increasing ground-water demand. A variety of methods were used to measure aquifer-system response to injection. Water levels were measured continuously in nested (multi-depth) piezometers and monitoring wells and periodically in other wells that were within several miles of the injection site. Microgravity surveys were done to estimate changes in the elevation of the water table in the absence of wells and to estimate specific yield. Aquifer-system deformation was measured directly and continuously using a dual borehole extensometer and indirectly using continuous Global Positioning System (GPS), first-order spirit leveling, and an array of tiltmeters. The injected water and extracted water were sampled periodically and analyzed for constituents, including chloride and trihalomethanes. Measured injection rates of about 750 gallons per minute (gal/min) per well at the injection site during a 5-month period showed that injection at or above the average extraction rates at that site (about 800 gal/min) was

  4. Testing of Photomultiplier Tubes in a Magnetic Field

    Science.gov (United States)

    Waldron, Zachary; A1 Collaboration

    2016-09-01

    The A1 collaboration at MAMI in Mainz, Germany has designed a neutron detector that can be used in experiments to measure the electric form factor of the neutron. They will measure elastic scattering from the neutron, using the polarized electron beam from MAMI at A1's experimental hall. The detector will be composed of two walls of staggered scintillator bars which will be read out by photomultiplier tubes (PMT), connected to both ends of each scintillator via light guides. The experiment requires a magnetic field with strength of 1 Tesla, 2m away from the first scintillator wall. The resulting fringe field is sufficient to disrupt the PMTs, despite the addition of Mu Metal shielding. The effects of the fringe field on these PMTs was tested to optimize the amplification of the PMTs. A Helmholtz Coil was designed to generate a controlled magnetic field with equivalent strength to the field that the PMTs will encounter. The PMTs were read out using a multi-channel analyzer, were tested at various angles relative to the magnetic field in order to determine the optimal orientation to minimize signal disruption. Tests were also performed to determine: the neutron detector response to cosmic radiation; and the best method for measuring a magnetic field's strength in two dimensions. National Science Foundation Grant No. IIA-1358175.

  5. Field evaluation of a horizontal well recirculation system for groundwater treatment: Pilot test at the Clean Test Site Portsmouth Gaseous Diffusion Plant, Piketon, Ohio

    Energy Technology Data Exchange (ETDEWEB)

    Muck, M.T.; Kearl, P.M.; Siegrist, R.L. [and others

    1998-08-01

    This report presents the results of field testing a horizontal well recirculation system at the Portsmouth Gaseous Diffusion Plant (PORTS). The recirculation system uses a pair of horizontal wells, one for groundwater extraction and treatment and the other for reinjection of treated groundwater, to set up a recirculation flow field. The induced flow field from the injection well to the extraction well establishes a sweeping action for the removal and treatment of groundwater contaminants. The overall purpose of this project is to study treatment of mixed groundwater contaminants that occur in a thin water-bearing zone not easily targeted by traditional vertical wells. The project involves several research elements, including treatment-process evaluation, hydrodynamic flow and transport modeling, pilot testing at an uncontaminated site, and pilot testing at a contaminated site. The results of the pilot test at an uncontaminated site, the Clean Test Site (CTS), are presented in this report.

  6. Pharmacokinetic and pharmacodynamic testing of marbofloxacin administered as a single injection for the treatment of bovine respiratory disease.

    Science.gov (United States)

    Vallé, M; Schneider, M; Galland, D; Giboin, H; Woehrlé, F

    2012-12-01

    New approaches in Pharmacokinetic/Pharmacodynamic (PK/PD) integration suggested that marbofloxacin, a fluoroquinolone already licensed for the treatment of bovine respiratory disease at a daily dosage of 2 mg/kg for 3-5 days, would be equally clinically effective at 10 mg/kg once (Forcyl(®)), whilst also reducing the risk of resistance. This marbofloxacin dosage regimen was studied using mutant prevention concentration (MPC), PK simulation, PK/PD integration and an in vitro dynamic system. This system simulated the concentration-time profile of marbofloxacin in bovine plasma established in vivo after a single 10 mg/kg intramuscular dose and killing curves of field isolated Pasteurellaceae strains of high (minimum inhibitory concentration (MIC) MIC ≤ 0.03 μg/mL), average (MIC of 0.12-0.25 μg/mL) and low (MIC of 1 μg/mL) susceptibility to marbofloxacin. The marbofloxacin MPC values were 2- to 4-fold the MIC values for all Mannheimia haemolytica, Pasteurella multocida tested. Marbofloxacin demonstrated a concentration-dependent killing profile with bactericidal activity observed within 1 h for most strains. No resistance development (MIC ≥ 4 μg/mL) was detected in the dynamic tests. Target values for risk of resistance PK/PD surrogates (area under the curve (AUC) AUC(24 h) /MPC and T(>MPC) /T(MSW) ratio) were achieved for all clinically susceptible pathogens. The new proposed dosing regimen was validated in vitro and by PK/PD integration confirming the single-injection short-acting antibiotic concept.

  7. Electromagnetic field analysis and RFEC signal modeling for gap measurement between liquid injection nozzle and nuclear fuel channel

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hoon; Jung, Hyun Kyu; Cheong, Yong Moo; Huh, Young; Lee, Yoon Sang [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2004-05-15

    Fuel channels including pressure tube(Pt) and calandria tube(CT) are important components of pressurized heavy water reactor(PHWR). A sagging of fuel channel increases by heat and radiation exposure with the increasing operation time. The contact of fuel channel to liquid injection nozzle(LIN) is thus a critical issue in power plant safety. In order to solve this safety issue, the electromagnetic technique was applied to compliment the present inspection technology. Electromagnetic fields were investigated for the gap measurement between CT and LIN using FEM computer modeling. We calculated the electromagnetic fields, such as, magnetic flux density, current density near the fuel channel and checked the adaptability of RFEC technology. The RFEC Signals using the volume integral method(VIM) were simulated for obtaining the optimal inspection parameters, including frequency, inter-coil spacing, coil size and configuration. Finally, we development the remote field eddy current sensor that can CT/LIN gap measurement efficiently.

  8. On the dynamics of Cu ions injection into low-k nanoporous materials under oscillating applied fields

    Science.gov (United States)

    Borja, Juan; Plawsky, Joel. L.; Lu, T.-M.; Gill, William N.

    2013-01-01

    Cu injection into low-k dielectrics was studied using oscillating bipolar field experiments coupled with a mass transport model. Cu/SiCOH/Si structures were stressed using an oscillating square bipolar applied field at 200 °C. Breakdown was defined experimentally as the time it takes for the leakage current to exceed 1 × 10-5 A under given stress conditions. Time to failure was found to depend on field oscillating frequency and amplitude of the applied field. It was determined that ion solubility primarily affects the magnitude of lifetime enhancement, while mobility affects its onset in the frequency domain. Overtime, the local field generated by the accumulation of Cu ions during bias temperature stress resists the action of the oscillating field thus inhibiting the ability to sweep ions from cathode to anode through reversal of the applied field and thereby limits the observed lifetime enhancement. Predictions from the model match trends for experimental data involving transport of Cu ions into SiCOH.

  9. DOE Field Operations Program EV and HEV Testing

    Energy Technology Data Exchange (ETDEWEB)

    Francfort, James Edward; Slezak, L. A.

    2001-10-01

    The United States Department of Energy’s (DOE) Field Operations Program tests advanced technology vehicles (ATVs) and disseminates the testing results to provide fleet managers and other potential ATV users with accurate and unbiased information on vehicle performance. The ATVs (including electric, hybrid, and other alternative fuel vehicles) are tested using one or more methods - Baseline Performance Testing (EVAmerica and Pomona Loop), Accelerated Reliability Testing, and Fleet Testing. The Program (http://ev.inel.gov/sop) and its nine industry testing partners have tested over 30 full-size electric vehicle (EV) models and they have accumulated over 4 million miles of EV testing experience since 1994. In conjunction with several original equipment manufacturers, the Program has developed testing procedures for the new classes of hybrid, urban, and neighborhood EVs. The testing of these vehicles started during 2001. The EVS 18 presentation will include (1) EV and hybrid electric vehicle (HEV) test results, (2) operating experience with and performance trends of various EV and HEV models, and (3) experience with operating hydrogen-fueled vehicles. Data presented for EVs will include vehicle efficiency (km/kWh), average distance driven per charge, and range testing results. The HEV data will include operating considerations, fuel use rates, and range testing results.

  10. Reduction of contrast medium volume in abdominal aorta CTA: Multiphasic injection technique versus a test bolus volume

    Energy Technology Data Exchange (ETDEWEB)

    Nijhof, Wouter H., E-mail: w.h.nijhof@student.utwente.nl [University of Twente, MIRA-Institute for Biomedical Technology and Technical Medicine, P.O. Box 21, 7500 AE Enschede (Netherlands); Vos, Charlotte S. van der, E-mail: c.s.vandervos@student.utwente.nl [University of Twente, MIRA-Institute for Biomedical Technology and Technical Medicine, P.O. Box 21, 7500 AE Enschede (Netherlands); Anninga, Bauke, E-mail: b.anninga@student.utwente.nl [University of Twente, MIRA-Institute for Biomedical Technology and Technical Medicine, P.O. Box 21, 7500 AE Enschede (Netherlands); Jager, Gerrit J., E-mail: g.jager@JBZ.nl [Department of Radiology, Jeroen Bosch Hospital, Henri Dunantstraat 1, 5223 GZ ’s-Hertogenbosch (Netherlands); Rutten, Matthieu J.C.M., E-mail: mj.rutten@online.nl [Department of Radiology, Jeroen Bosch Hospital, Henri Dunantstraat 1, 5223 GZ ’s-Hertogenbosch (Netherlands)

    2013-09-15

    Objective: The purpose of this study is to reduce the administered contrast medium volume in abdominal CTA by using a test bolus injection, with the preservation of adequate quantitative and qualitative vessel enhancement. Study design: For this technical efficacy study 30 patients, who were referred for a CTA examination of the abdominal aorta, were included. Randomly 15 patients were assigned to undergo a multiphasic injection protocol and received 89 mL of contrast medium (Optiray 350) (protocol I). Fifteen patients were assigned to the test bolus injection protocol (protocol II), which implies injection of a 10 mL test bolus of Optiray 350 prior to performing CTA with a 40 mL of contrast medium. Quantitative assessment of vascular enhancement was performed by measuring the amount of Hounsfield Units in the aorta at 30 positions from the celiac trunk to the iliac arteries in both groups. Qualitative assessment was performed by three radiologists who scored the images at a 5-point scale. Results: Quantitative assessment showed that there was no significant difference in vascular enhancement for patients between the two protocols, with mean attenuation values of 280.9 ± 50.84 HU and 258.60 ± 39.28 HU, respectively. The image quality of protocol I was rated 4.31 (range: 3.67/5.00) and of protocol II 4.11 (range: 2.67/5.00). These differences were not statistically significant. Conclusion: This study showed that by using a test bolus injection and the administration of 50 mL of contrast medium overall, CTA of the abdominal aorta can reliably be performed, with regard to quantitative and qualitative adequate vessel enhancement.

  11. Interim Report of Field Test of Expedient Pavement Repairs (Test Items 1-15).

    Science.gov (United States)

    1980-03-01

    OF FIELD TEST OFEXPEDIENT PAVEMENT REPAIRS ( TEST ITEMS 1-15). RAYMONDS.4OLLINGS lWGINE E :AH1 DIVISION .I MARŜ 6 // il) JNTEIM REPUT TiJUL1077...Pavement Repairs ( Test Items 1-15) 6 PERFORMING ORG. REPORT NUMBER 7. AUTHOR(&) S. CONTRACT OR GRANT NUMBER(&) Raymond S. Rollings 9. PERFORMING...21 Item 14 Test Results .................... 33 22 Density Results, Item 15....................34 23 Summary of Test Items ......................37 24

  12. Solid reactors in sequential injection analysis: Recent trends in the environmental field

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    /reagent consumption. A further noteworthy feature is the inherent versatility of the flow network to implement unit operations at will with no need for manifold re-configuration. The present review discusses the potential of SI to accommodate solid reactors and packed columns in the flow set-up for environmental......-bead injection (SI-BI), used in either the jet-ring or lab-on-valve configurations, is presented as a front-end to many detectors. This article also outlines recent trends focused on exploiting SI as an automated tool for handling solid samples of environmental concern and accommodating dynamic fractionation...

  13. Lithologic Framework Modeling of the Fruitvale Oil Field Investigating Interaction Between Wastewater Injection Wells and Usable Groundwater

    Science.gov (United States)

    Treguboff, E. W.; Crandall-Bear, A. T.

    2015-12-01

    The Fruitvale Oil Field lies in a populated area where oil production, water disposal injection wells, and drinking water wells lie in close proximity. The purpose of this project is to build a lithological framework of the area that can then be used to determine if water disposal from petroleum production has a chance of reaching usable groundwater aquifers. Using the DOGGR database, data were collected from well logs. Lithologic data from drilling logs and cores were coded and entered into a relational database, where it was combined with the surface elevation and location coordinates of each well. Elevation data was acquired through ArcGIS using a USGS 24k 10 m DEM. Drillers logs that started at the surface, and were continuous, were sorted by the density of intervals recorded, in order to select high quality drillers logs for use in creating a model. About 900 wells were coded and approximately 150 wells were used in the model. These wells were entered into the modeling program (Rockworks), which allowed the wells to be visualized as strip logs and also as cross sections, and 2D fence models were created to represent subsurface conditions. The data were interpolated into 3D models of the subsurface. Water disposal wells, with the depths of the perforation intervals as well as injection volume, were added to the model, and analyzed. Techniques of interpolation used in this project included kriging, which requires statistical analysis of the data collected. This allowed correlation between widely-spaced wells. Up scaling the data to a coarse or fine texture was also been found to be effective with the kriging technique. The methods developed on this field can be used to build framework models of other fields in the Central Valley to explore the relationship between water disposal injection and usable groundwater.

  14. Design and development of a helium injection system to improve external leakage detection during liquid nitrogen immersion tests

    Science.gov (United States)

    Townsend, Andrew; Mishra, Rakesh

    2016-10-01

    The testing of assemblies for use in cryogenic systems commonly includes evaluation at or near operating (therefore cryogenic) temperature. Typical assemblies include valves and pumps for use in liquid oxygen-liquid hydrogen rocket engines. One frequently specified method of cryogenic external leakage testing requires the assembly, pressurized with gaseous helium (GHe), be immersed in a bath of liquid nitrogen (LN2) and allowed to thermally stabilize. Component interfaces are then visually inspected for leakage (bubbles). Unfortunately the liquid nitrogen will be boiling under normal, bench-top, test conditions. This boiling tends to mask even significant leakage. One little known and perhaps under-utilized property of helium is the seemingly counter-intuitive thermodynamic property that when ambient temperature helium is bubbled through boiling LN2 at a temperature of -195.8 °C, the temperature of the liquid nitrogen will reduce. This paper reports on the design and testing of a novel proof-of-concept helium injection control system confirming that it is possible to reduce the temperature of an LN2 bath below boiling point through the controlled injection of ambient temperature gaseous helium and then to efficiently maintain a reduced helium flow rate to maintain a stabilized liquid temperature, enabling clear visual observation of components immersed within the LN2. Helium saturation testing is performed and injection system sizing is discussed.

  15. Dexamethasone Injection

    Science.gov (United States)

    ... body tissues,) gastrointestinal disease, and certain types of arthritis. Dexamethasone injection is also used for diagnostic testing. ... effects.tell your doctor if you have a fungal infection (other than on your skin or nails). ...

  16. Tracer Tests and Field Monitoring of In situ Bioreduction of Cr(VI) Bioreduction at the Hanford 100H Site

    Science.gov (United States)

    Long, P. E.; Newcomer, D. R.; Resch, C. T.; Cantrell, K.; Faybishenko, B.; Hazen, T. C.; Brodie, E.; Joyner, D.; Borglin, S.; Conrad, M.; Tokunaga, T.; Wan, J.; Hubbard, S.; Williams, K. H.; Peterson, J. E.; Firestone, M.; Andersen, G.; Desantis, T.; Hanlon, J.; Willett, A.; Koenigsberg, S.

    2006-05-01

    Tracer tests and field monitoring before, during, and after bio-immobilization of Cr(VI) in groundwater at the Hanford 100H field site have provided key data constraining the geohydrology and biogeochemistry of field- scale bioreduction. A slow release polylactate, Hydrogen Release Compound (HRC), was used to stimulate the in situ bioreduction and removal of Cr(VI) from groundwater. Monitoring included an extensive suite of field and laboratory techniques, as well as five Br-tracer injection tests and four pumping tests. To minimize drilling costs, a three-well system (injection well and upgradient and downgradient monitoring wells) was used for conducting the in situ biostimulation and monitoring. Pre-biostimulation Br-tracer tests demonstrated that low-flow pumping (1.2 to 2.5 l/min) on the down-gradient well was required to ensure capture of groundwater flow lines passing through the injection well (5 m from the downgradient pumping well). Detailed Br breakthrough curves were obtained using field-deployed Br ion-selective electrodes (Instrumentation Northwest, Inc.). We also used a multi-parameter flow cell (Hydrolab H2O Multiprobe) to collect hourly data on temperature, pH, redox potential, electrical conductivity, and dissolved oxygen (DO). Field measurements were used to enable repeat groundwater sampling by pumping through specially designed borehole water samplers. Following the HRC injection, the data demonstrated the temporal relationship between the Br arrival and onset of reducing conditions induced by the injection. For example, redox potential decreased from +240 to -130 mV while conductivity changed from ~510 μS/cm to ~850 μS/cm along with a complete removal of DO and a drop in pH. These changes occurred concomitantly with more than a 2- order of magnitude increase in microbial cell numbers. The pore-water conductivity changes were used to constrain interpretation of the results of cross-borehole radar tomography conducted prior to and after the

  17. Use of remifentanil to reduce propofol injection pain and the required propofol dose in upper digestive tract endoscopy diagnostic tests

    Directory of Open Access Journals (Sweden)

    Gustavo Nadal Uliana

    2015-12-01

    Full Text Available BACKGROUND AND OBJECTIVES: The introduction of propofol (2,6-diisopropylphenol as a sedative agent has transformed the area of sedation for endoscopic procedures. However, a major drawback of sedation with the use of propofol is its high incidence of injection pain. The most widely used technique in reducing propofol injection pain is through the association of other drugs. The aim of this study was to evaluate the effect of remifentanil-propofol combination on the incidence of propofol injection pain and its influence on the total dose of propofol required for sedation in upper digestive tract endoscopy (UDE diagnostic tests. METHOD: One hundred and five patients undergoing upper digestive tract endoscopy were evaluated and randomly divided into 3 groups of 35 patients each. The Control Group received propofol alone; Study-group 1 received remifentanil at a fixed dose of 0.2 mg/kg combined with propofol; Study-group 2 received remifentanil at a fixed dose of 0.3 mg/kg combined with propofol. The incidence of propofol injection pain and the total dose of propofol required for the test were evaluated. The sample was very similar regarding age, weight, height, sex, and physical status. Statistical analysis was performed according to the nature of the evaluated data. Student'st-test was used to compare the mean of age, weight, height (cm, and dose (mg/kg variables between groups. The χ2 test was used to compare sex, physical status, and propofol injection pain between groups. The significance level was a < 0.05. RESULTS: There was significant statistical difference between the study groups and the control group regarding the parameters of propofol injection pain and total dose of propofol (mg/kg used. However, there were no statistical differences between the two study groups for these parameters. CONCLUSION: We conclude that the use of remifentanil at doses of 0.2 mg/kg and 0.3 mg/kg was effective for reducing both the propofol injection pain and

  18. Field tests-low input, side-wall vented boiler

    Energy Technology Data Exchange (ETDEWEB)

    Litzke, W.L.; Butcher, T.A.; Celebi, Y. [Brookhaven National Lab., Upton, NY (United States)

    1996-07-01

    The Fan Atomized Burner (FAB) was developed at Brookhaven National Laboratory as part of the Oil Heat Combustion Equipment Technology Program to provide a practical low-firing rate technology leading to new, high efficiency oil-fired appliances. The development of the burner design and results of application testing have been presented in prior oil heat conferences over the past several years. This information is also summarized in a more comprehensive BNL report. The first field trial of a prototype unit was initiated during the 1994-95 heating season. This paper presents the results of the second year of testing, during the 1995-96 heating season. The field tests enable the demonstration of the reliability and performance of the FAB under practical, typical operating conditions. Another important objective of the field test was to demonstrate that the low input is adequate to satisfy the heating and hot water demands of the household. During the first field trial it was shown that at a maximum input rate of 0.4 gph (55,000 Btu/hr) the burner was able to heat a home with over 2,000 square feet of conditioned living space and provide adequate supply of domestic hot water for a family of six. The test is located in Long Island, NY.

  19. DNA-based small molecules for hole charge injection and channel passivation in organic heptazole field effect transistors

    Science.gov (United States)

    Cho, Youngsuk; Lee, Junyeong; Lim, June Yeong; Yu, Sanghyuck; Yi, Yeonjin; Im, Seongil

    2017-02-01

    DNA-based small molecules of guanine, cytosine, thymine and adenine are adopted for the charge injection layer between the Au electrodes and organic semiconductor, heptazole (C26H16N2). The heptazole-channel organic field effect transistors (OFETs) with a DNA-based small molecule charge injection layer showed higher hole mobility (maximum 0.12 cm2 V-1 s-1) than that of a pristine device (0.09 cm2 V-1 s-1). We characterized the contact resistance of each device by a transfer length method (TLM) and found that the guanine layer among all DNA-based materials performs best as a hole injection layer leading to the lowest contact resistance. Since the guanine layer is also known to be a proper channel passivation layer coupled with a thin conformal Al2O3 layer protecting the channel from bias stress and ambient molecules, we could realize ultra-stable OFETs utilizing guanine/Au contact and guanine/Al2O3 bilayer on the organic channel.

  20. Heavy oil reservoir evaluation : performing an injection test using DST tools in the marine region of Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Loaiza, J.; Ruiz, P. [Halliburton, Mexico City (Mexico); Barrera, D.; Gutierrez, F. [Pemex, Mexico City (Mexico)

    2010-07-01

    This paper described an injection test conducted to evaluate heavy oil reserves in an offshore area of Mexico. The drill-stem testing (DST) evaluation used a fluid injection technique in order to eliminate the need for artificial lift and coiled tubing. A pressure transient analysis method was used to determine the static pressure of the reservoir, effective hydrocarbon permeability, and formation damage. Boundary effects were also characterized. The total volume of the fluid injection was determined by analyzing various reservoir parameters. The timing of the shut-in procedure was determined by characterizing rock characteristics and fluids within the reservoir. The mobility and diffusivity relationships between the zones with the injection fluids and reservoir fluids were used to defined sweep fluids. A productivity analysis was used to predict various production scenarios. DST tools were then used to conduct a pressure-production assessment. Case histories were used to demonstrate the method. The studies showed that the method provides a cost-effective means of providing high quality data for productivity analyses. 4 refs., 2 tabs., 15 figs.

  1. U.S. field testing programs and results

    Energy Technology Data Exchange (ETDEWEB)

    Wicks, G.G.

    2000-06-09

    The United States has been active in four major international in-situ or field testing programs over the past two decades, involving the burial of simulated high-level waste forms and package components. These programs are designed to supplement laboratory testing studies in order to obtain the most complete and realistic picture possible of waste glass behavior under realistic repository-relevant conditions.

  2. Sequential accelerated tests: Improving the correlation of accelerated tests to module performance in the field

    Science.gov (United States)

    Felder, Thomas; Gambogi, William; Stika, Katherine; Yu, Bao-Ling; Bradley, Alex; Hu, Hongjie; Garreau-Iles, Lucie; Trout, T. John

    2016-09-01

    DuPont has been working steadily to develop accelerated backsheet tests that correlate with solar panels observations in the field. This report updates efforts in sequential testing. Single exposure tests are more commonly used and can be completed more quickly, and certain tests provide helpful predictions of certain backsheet failure modes. DuPont recommendations for single exposure tests are based on 25-year exposure levels for UV and humidity/temperature, and form a good basis for sequential test development. We recommend a sequential exposure of damp heat followed by UV then repetitions of thermal cycling and UVA. This sequence preserves 25-year exposure levels for humidity/temperature and UV, and correlates well with a large body of field observations. Measurements can be taken at intervals in the test, although the full test runs 10 months. A second, shorter sequential test based on damp heat and thermal cycling tests mechanical durability and correlates with loss of mechanical properties seen in the field. Ongoing work is directed toward shorter sequential tests that preserve good correlation to field data.

  3. Interim Report: 100-NR-2 Apatite Treatability Test: Low Concentration Calcium Citrate-Phosphate Solution Injection for In Situ Strontium-90 Immobilization

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Mark D.; Fritz, Brad G.; Mendoza, Donaldo P.; Rockhold, Mark L.; Thorne, Paul D.; Xie, YuLong; Bjornstad, Bruce N.; Mackley, Rob D.; Newcomer, Darrell R.; Szecsody, James E.; Vermeul, Vincent R.

    2008-07-11

    Following an evaluation of potential Sr-90 treatment technologies and their applicability under 100-NR-2 hydrogeologic conditions, U.S. Department of Energy, Fluor Hanford, Inc., Pacific Northwest National Laboratory, and the Washington Department of Ecology agreed that the long-term strategy for groundwater remediation at 100-N Area will include apatite sequestration as the primary treatment, followed by a secondary treatment if necessary (most likely phytoremediation). Since then, the agencies have worked together to agree on which apatite sequestration technology has the greatest chance of reducing Sr-90 flux to the river at a reasonable cost. In July 2005, aqueous injection, (i.e., the introduction of apatite-forming chemicals into the subsurface) was endorsed as the interim remedy and selected for field testing. Studies are in progress to assess the efficacy of in situ apatite formation by aqueous solution injection to address both the vadose zone and the shallow aquifer along the 300 ft of shoreline where Sr-90 concentrations are highest. This report describes the field testing of the shallow aquifer treatment.

  4. CAPILLARY PRESSURE/MERCURY INJECTION ANALYSIS: CHEROKEE AND BUG FIELDS, SAN JUAN COUNTY, UTAH

    Energy Technology Data Exchange (ETDEWEB)

    Thomas C. Chidsey Jr; David E. Eby

    2003-12-01

    Over 400 million barrels (64 million m{sup 3}) of oil have been produced from the shallow-shelf carbonate reservoirs in the Pennsylvanian (Desmoinesian) Paradox Formation in the Paradox Basin, Utah and Colorado. With the exception of the giant Greater Aneth field, the other 100 plus oil fields in the basin typically contain 2 to 10 million barrels (0.3-1.6 million m{sup 3}) of original oil in place. Most of these fields are characterized by high initial production rates followed by a very short productive life (primary), and hence premature abandonment. Only 15 to 25 percent of the original oil in place is recoverable during primary production from conventional vertical wells. An extensive and successful horizontal drilling program has been conducted in the giant Greater Aneth field. However, to date, only two horizontal wells have been drilled in small Ismay and Desert Creek fields. The results from these wells were disappointing due to poor understanding of the carbonate facies and diagenetic fabrics that create reservoir heterogeneity. These small fields, and similar fields in the basin, are at high risk of premature abandonment. At least 200 million barrels (31.8 million m{sup 3}) of oil will be left behind in these small fields because current development practices leave compartments of the heterogeneous reservoirs undrained. Through proper geological evaluation of the reservoirs, production may be increased by 20 to 50 percent through the drilling of low-cost single or multilateral horizontal legs from existing vertical development wells. In addition, horizontal drilling from existing wells minimizes surface disturbances and costs for field development, particularly in the environmentally sensitive areas of southeastern Utah and southwestern Colorado.

  5. Yucca Mountain site characterization: The field testing program

    Energy Technology Data Exchange (ETDEWEB)

    Williams, D.R.; Matthusen, A.C.

    1994-12-31

    The Yucca Mountain area was first considered as a site for possible characterization as a high level waste repository in 1977. Since that time preliminary field testing and Congressional directive recommended continued testing and determined in 1987 that Yucca Mountain would be the only site characterized. Following environmental assessment, the development of a site characterization plan, and litigation with the State of Nevada testing from both surface-based perspective and underground in the Exploratory Studies Facility is underway. Data and analyses from the comprehensive testing program will be evaluated on a periodic basis of two year cycles to provide direction to the testing program. The entire testing program will culminate in a determination of site suitability near the end of the twentieth century.

  6. Test chambers for cell culture in static magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Glinka, Marek, E-mail: mag@iq.pl [Research and Development Centre of Electrical Machines. 188 Rozdzienskiego Street, 40-203 Katowice (Poland); Gawron, Stanisław, E-mail: s.gawron@komel.katowice.pl [Research and Development Centre of Electrical Machines. 188 Rozdzienskiego Street, 40-203 Katowice (Poland); Sieroń, Aleksander, E-mail: sieron1@tlen.pl [Department of Internal Diseases, Angiology and Physical Medicine in Bytom. Medical University of Silesia in Katowice. 15 Batorego Street, 41-902 Bytom (Poland); Pawłowska–Góral, Katarzyna, E-mail: kgoral@sum.edu.pl [Department of Food and Nutrition in Sosnowiec. Medical University of Silesia in Katowice. 8 Jednosci Street, 41-200 Sosnowiec (Poland); Cieślar, Grzegorz, E-mail: cieslar1@tlen.pl [Department of Internal Diseases, Angiology and Physical Medicine in Bytom. Medical University of Silesia in Katowice. 15 Batorego Street, 41-902 Bytom (Poland); Sieroń–Stołtny, Karolina [Department of Internal Diseases, Angiology and Physical Medicine in Bytom. Medical University of Silesia in Katowice. 15 Batorego Street, 41-902 Bytom (Poland)

    2013-04-15

    Article presents a test chamber intended to be used for in vitro cell culture in homogenous constant magnetic field with parametrically variable magnitude. We constructed test chambers with constant parameters of control homeostasis of cell culture for the different parameters of static magnetic field. The next step was the computer calculation of 2D and 3D simulation of the static magnetic field distribution in the chamber. The analysis of 2D and 3D calculations of magnetic induction in the cells' exposition plane reveals, in comparison to the detection results, the greater accuracy of 2D calculations (Figs. 9 and 10). The divergence in 2D method was 2–4% and 8 to 10% in 3D method (reaching 10% only out of the cells′ cultures margins). -- Highlights: ► We present test chamber to be used for in vitro cell culture in static magnetic field. ► The technical data of the chamber construction was presented. ► 2D versus 3D simulation of static magnetic field distribution in chamber was reported. ► We report the accuracy of 2D calculation than 3D.

  7. INTERMITTENT VERSUS CONTINUOUS INCREMENTAL FIELD TESTS: ARE MAXIMAL VARIABLES INTERCHANGEABLE?

    Directory of Open Access Journals (Sweden)

    Lorival J. Carminatti

    2013-03-01

    Full Text Available The aim of the present study was to compare physiological responses derived from an incremental progressive field test with a constant speed test i.e. intermittent versus continuous protocol. Two progressive maximum tests (Carminatti`s test (T-CAR and the Vameval test (T-VAM, characterized by increasing speed were used. T-CAR is an intermittent incremental test, performed as shuttle runs; while T-VAM is a continuous incremental test performed on an athletic track. Eighteen physically active, healthy young subjects (21.9 ± 2.0 years; 76.5 ± 8.6 kg, 1.78 ± 0.08 m, 11.2 ± 5.4% body fat, volunteered for this study. Subjects performed four different maximum test sessions conducted in the field: two incremental tests and two time to exhaustion tests (TTE at peak test velocities (PV. No significant differences were found for PV (T-CAR = 15.6 ± 1.2; T-VAM = 15.5 ± 1.3 km·h-1 and maximal HR (T-CAR = 195 ± 11; T- VAM = 194 ± 14 bpm. During TTE, there were no significant differences for HR (TTET-CAR and TTET-VAM = 192 ± 12 bpm. However, there was a significant difference in TTE (p = 0.04 (TTET-CAR = 379 ± 84, TTET-VAM = 338 ± 58 s with a low correlation (r = 0.41. The blood lactate concentration measured at the end of the TTE tests, showed no significant difference (TTET-CAR = 13.2 ± 2.4 vs. TTET-VAM = 12.9 ± 2.4 mmol·l-1. Based on the present findings, it is suggested that the maximal variables derived from T-CAR and T-VAM can be interchangeable in the design of training programs.

  8. Optical second harmonic generation measurements for investigating electron injection into a pentacene field effect transistor with Au source and drain electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Eunju; Manaka, Takaaki; Tamura, Ryosuke [Department of Physical Electronics, Tokyo Institute of Technology, 2-12-1, O-okayama, Meguro-ku, Tokyo 152-8552 (Japan); Iwamoto, Mitsumasa [Department of Physical Electronics, Tokyo Institute of Technology, 2-12-1, O-okayama, Meguro-ku, Tokyo 152-8552 (Japan)], E-mail: iwamoto@pe.titech.ac.jp

    2008-03-03

    The pentacene field effect transistors (FETs)' operation for the injection carrier was revealed by means of the drain current-elapsed time (I{sub ds}-t) and optical second harmonic generation (SHG) measurements. The charge carriers forming the conducting channel of pentacene FETs were mainly holes injected from the Au source electrode. Carrier injection from source and drain electrodes was followed by the carrier trapping, and the SHG signal modulated by the change in the electric field distribution between Au the source and drain electrodes was shown. In particular, at the off state of the FET, electron injection and succeeding trapping were suggested. Furthermore, hole injection assisted by trapped electrons was also suggested.

  9. The virtual fields method applied to spalling tests on concrete

    Science.gov (United States)

    Pierron, F.; Forquin, P.

    2012-08-01

    For one decade spalling techniques based on the use of a metallic Hopkinson bar put in contact with a concrete sample have been widely employed to characterize the dynamic tensile strength of concrete at strain-rates ranging from a few tens to two hundreds of s-1. However, the processing method mainly based on the use of the velocity profile measured on the rear free surface of the sample (Novikov formula) remains quite basic and an identification of the whole softening behaviour of the concrete is out of reach. In the present paper a new processing method is proposed based on the use of the Virtual Fields Method (VFM). First, a digital high speed camera is used to record the pictures of a grid glued on the specimen. Next, full-field measurements are used to obtain the axial displacement field at the surface of the specimen. Finally, a specific virtual field has been defined in the VFM equation to use the acceleration map as an alternative `load cell'. This method applied to three spalling tests allowed to identify Young's modulus during the test. It was shown that this modulus is constant during the initial compressive part of the test and decreases in the tensile part when micro-damage exists. It was also shown that in such a simple inertial test, it was possible to reconstruct average axial stress profiles using only the acceleration data. Then, it was possible to construct local stress-strain curves and derive a tensile strength value.

  10. Intermittent versus Continuous Incremental Field Tests: Are Maximal Variables Interchangeable?

    Science.gov (United States)

    Carminatti, Lorival J; Possamai, Carlos A P; de Moraes, Marcelo; da Silva, Juliano F; de Lucas, Ricardo D; Dittrich, Naiandra; Guglielmo, Luiz G A

    2013-01-01

    The aim of the present study was to compare physiological responses derived from an incremental progressive field test with a constant speed test i.e. intermittent versus continuous protocol. Two progressive maximum tests (Carminatti`s test (T-CAR) and the Vameval test (T-VAM)), characterized by increasing speed were used. T-CAR is an intermittent incremental test, performed as shuttle runs; while T-VAM is a continuous incremental test performed on an athletic track. Eighteen physically active, healthy young subjects (21.9 ± 2.0 years; 76.5 ± 8.6 kg, 1.78 ± 0.08 m, 11.2 ± 5.4% body fat), volunteered for this study. Subjects performed four different maximum test sessions conducted in the field: two incremental tests and two time to exhaustion tests (TTE) at peak test velocities (PV). No significant differences were found for PV (T-CAR = 15.6 ± 1.2; T-VAM = 15.5 ± 1.3 km·h(-1)) and maximal HR (T-CAR = 195 ± 11; T- VAM = 194 ± 14 bpm). During TTE, there were no significant differences for HR (TTET-CAR and TTET-VAM = 192 ± 12 bpm). However, there was a significant difference in TTE (p = 0.04) (TTET-CAR = 379 ± 84, TTET-VAM = 338 ± 58 s) with a low correlation (r = 0.41). The blood lactate concentration measured at the end of the TTE tests, showed no significant difference (TTET-CAR = 13.2 ± 2.4 vs. TTET-VAM = 12.9 ± 2.4 mmol·l(-1)). Based on the present findings, it is suggested that the maximal variables derived from T-CAR and T-VAM can be interchangeable in the design of training programs. Key pointsT-CAR is an intermittent shuttle run test that predicts the maximal aerobic speed with accuracy, hence, test results could be interchangeable with continuous straight-line tests.T-CAR provides valid field data for evaluating aerobic fitness.In comparison with T-VAM, T-CAR may be a more favourable way to prescribe intermittent training using a shuttle-running protocol.

  11. Lorentz breaking Effective Field Theory and observational tests

    CERN Document Server

    Liberati, Stefano

    2012-01-01

    Analogue models of gravity have provided an experimentally realizable test field for our ideas on quantum field theory in curved spacetimes but they have also inspired the investigation of possible departures from exact Lorentz invariance at microscopic scales. In this role they have joined, and sometime anticipated, several quantum gravity models characterized by Lorentz breaking phenomenology. A crucial difference between these speculations and other ones associated to quantum gravity scenarios, is the possibility to carry out observational and experimental tests which have nowadays led to a broad range of constraints on departures from Lorentz invariance. We shall review here the effective field theory approach to Lorentz breaking in the matter sector, present the constraints provided by the available observations and finally discuss the implications of the persisting uncertainty on the composition of the ultra high energy cosmic rays for the constraints on the higher order, analogue gravity inspired, Lore...

  12. Intraperitoneal injections as a possible means of generating varied levels of methylmercury in the eggs of birds in field studies.

    Science.gov (United States)

    Heinz, Gary H; Hoffman, David J; Klimstra, Jon D; Stebbins, Katherine R

    2010-05-01

    The ideal study of the effects of methylmercury on the reproductive success of a species of bird would be one in which eggs contained mercury concentrations ranging from controls to very heavily contaminated, all at the same site. Such a study cannot be realized at a Hg-contaminated area or under laboratory conditions but could be achieved by introducing methylmercury into breeding females and allowing them to deposit Hg in their eggs. Female mallards (Anas platyrhynchos) were intraperitoneally injected with solutions of methylmercury chloride dissolved in corn oil, propylene glycol, dimethyl sulfoxide, mineral oil, Olestra, Crisco, lard, hard paraffin, and a combination of hard and soft paraffin. In some cases, egg laying was delayed, as a result of either the solvent itself (in the case of Olestra, Crisco, and lard) or the highest concentration of methylmercury chloride (500 microg/g) in some of the solvents. Mercury in eggs ranged from a control level (<0.1 microg/g) to approximately 14 microg/g on a wet weight basis, which more than covers the range of concentrations reported in wild bird eggs. Mercury concentrations in a series of eggs from the same female declined mostly as a result of excretion of Hg in prior eggs and not because of the length of time since the injection. Intraperitoneal injections hold promise in field studies in which one would like to study the reproductive effects of a wide range of methylmercury levels in the eggs of a wild bird and under the natural conditions that exist in the field. Copyright (c) 2010 SETAC.

  13. Controlling charge injection properties in polymer field-effect transistors by incorporation of solution processed molybdenum trioxide.

    Science.gov (United States)

    Long, Dang Xuan; Xu, Yong; Wei, Huai-xin; Liu, Chuan; Noh, Yong-Young

    2015-08-21

    A simply and facilely synthesized MoO3 solution was developed to fabricate charge injection layers for improving the charge-injection properties in p-type organic field-effect transistors (OFETs). By dissolving MoO3 powder in ammonium (NH3) solvent under an air atmosphere, an intermediate ammonium molybdate ((NH4)2MoO4) precursor is made stable, transparent and spin-coated to form the MoO3 interfacial layers, the thickness and morphology of which can be well-controlled. When the MoO3 layer was applied to OFETs with a cost-effective molybdenum (Mo) electrode, the field-effect mobility (μFET) was significantly improved to 0.17 or 1.85 cm(2) V(-1)s(-1) for polymer semiconductors, regioregular poly(3-hexylthiophene) (P3HT) or 3,6-bis-(5bromo-thiophen-2-yl)-N,N'-bis(2-octyl-1-dodecyl)-1,4-dioxo-pyrrolo[3,4-c]pyrrole (DPPT-TT), respectively. Device analysis indicates that the MoO3-deposited Mo contact exhibits a contact resistance RC of 1.2 MΩ cm comparable to that in a device with the noble Au electrode. Kelvin-probe measurements show that the work function of the Mo electrode did not exhibit a dependence on the thickness of MoO3 film. Instead, ultraviolet photoemission spectroscopy results show that a doping effect is probably induced by casting the MoO3 layer on the P3HT semiconductor, which leads to the improved hole injection.

  14. Hanna, Wyoming underground coal gasification data base. Volume 3. The Hanna II, Phase I field test

    Energy Technology Data Exchange (ETDEWEB)

    Bartke, T.C.; Fischer, D.D.; King, S.B.; Boyd, R.M.; Humphrey, A.E.

    1985-08-01

    This report is part of a seven-volume series on the Hanna, Wyoming, underground coal gasification field tests. Volume 1 is a summary of the project, and each of Volumes 2 through 6 describes a particular test. Volume 7 is a compilation of all the data for the tests in Volumes 2 through 6. Hanna II, Phase I was conducted during the spring and summer of 1975, at a site about 700 feet up dip (to the southwest) of the Hanna I test. The test was conducted in two stages - Phase IA and IB. Phase IA consisted of linking and gasification operations between Wells 1 and 3 and Phase IB of linking from the 1-3 gasification zone to Well 2, followed by a short period of gasification from Well 2 to Well 3 over a broad range of air injection rates, in order to determine system turndown capabilities and response times. This report covers: (1) site selection and characteristics; (2) test objectives; (3) facilities description; (4) pre-operational testing; (5) test operations summary; and (6) post-test activity. 7 refs., 11 figs., 8 tabs.

  15. Acceptance test report: Field test of mixer pump for 241-AN-107 caustic addition project

    Energy Technology Data Exchange (ETDEWEB)

    Leshikar, G.A.

    1997-05-16

    The field acceptance test of a 75 HP mixer pump (Hazleton serial number N-20801) installed in Tank 241-AN-107 was conducted from October 1995 thru February 1996. The objectives defined in the acceptance test were successfully met, with two exceptions recorded. The acceptance test encompassed field verification of mixer pump turntable rotation set-up and operation, verification that the pump instrumentation functions within established limits, facilitation of baseline data collection from the mixer pump mounted ultrasonic instrumentation, verification of mixer pump water flush system operation and validation of a procedure for its operation, and several brief test runs (bump) of the mixer pump.

  16. Layered Injection Testing Technology for Water Injection Wells in Jidong Oilfield%冀东油田注水井分层测试技术研究与应用∗

    Institute of Scientific and Technical Information of China (English)

    王金忠

    2015-01-01

    Water injection profile is measured mainly by the isotope method to acquire layered water absorp⁃tion of water injection wells�This method cannot measure startup pressure of small layers under different permeabili⁃ty levels and its measured results cannot effectively guide reasonable division of water injection sections�For the rea⁃son, a research is conducted on layered injection testing technology of immobile strings�The string mainly consists of hydraulic safety joint, hydraulic anchor, test valve, water plugging packer and extension tube�All layers to be tested are divided by the water plugging packer and opened one by one from bottom to top by using a pressure⁃building control test valve while the lower layer is closed�One trip of string could be used to complete construction for three to five layers�Field application results show that, the test process string is simple in the structure, relia⁃ble for setting and easy to operate�Test data can truly reflect startup pressure and water absorbing capacity of smal⁃ler layers and provide a reliable basis for layered injection measure decision making.%冀东油田目前主要通过同位素法测吸水剖面来认识注水井的分层吸水状况,这种方法无法测出各不同渗透率小层的启动压力,测试结果不能有效指导注水井分注段的合理划分,为此开展了不动管柱分层测试工艺管柱研究。该管柱主要由液压安全接头、水力锚、测试阀、卡水封隔器和伸缩管等组成,通过卡水封隔器将所有待测层卡分开来,再经投球憋压控制测试阀自下而上逐层开启同时关闭下一层后进行测试,一趟管柱可完成3~5层施工。现场应用结果表明,该测试工艺管柱结构简单,坐封可靠,易于操作,测试数据真实反映了小层启动压力和吸水能力,可为分层措施决策提供可靠依据。

  17. Joint inversion of time-lapse VSP data for monitoring CO2 injection at the Farnsworth EOR field in Texas

    Science.gov (United States)

    Zhang, M.; Gao, K.; Balch, R. S.; Huang, L.

    2016-12-01

    During the Development Phase (Phase III) of the U.S. Southwest Regional Partnership on Carbon Sequestration (SWP), time-lapse 3D vertical seismic profiling (VSP) data were acquired to monitor CO2 injection/migration at the Farnsworth Enhanced Oil Recovery (EOR) field, in partnership with the industrial partner Chaparral Energy. The project is to inject a million tons of carbon dioxide into the target formation, the deep oil-bearing Morrow Formation in the Farnsworth Unit EOR field. Quantitative time-lapse seismic monitoring has the potential to track CO2 movement in geologic carbon storage sites. Los Alamos National Laboratory (LANL) has recently developed new full-waveform inversion methods to jointly invert time-lapse seismic data for changes in elastic and anisotropic parameters in target monitoring regions such as a CO2 reservoir. We apply our new joint inversion methods to time-lapse VSP data acquired at the Farnsworth EOR filed, and present some preliminary results showing geophysical properties changes in the reservoir.

  18. Comparison of two field tests to estimate maximum aerobic speed.

    Science.gov (United States)

    Berthoin, S; Gerbeaux, M; Turpin, E; Guerrin, F; Lensel-Corbeil, G; Vandendorpe, F

    1994-08-01

    The measurement of maximal aerobic speed (MAS) and the prediction of maximal oxygen uptake (VO2 max) by means of field tests were carried out on 17 students studying physical education. The subjects underwent a continuous multi-stage track test (Léger and Boucher, 1980), shuttle test (Léger et al., 1984) and VO2 max measurement on a treadmill. The VO2 max values estimated using the track test (56.8 +/- 5.8 ml kg-1 min-1) were not significantly different from the values measured in the treadmill test (56.8 +/- 7.1 ml kg-1 min-1), but were higher than those estimated using the shuttle test (51.1 +/- 5.9 ml kg-1 min-1). The maximal nature of the tests was checked by measurement of heart rate and lactate concentration, taken within 2 min post-test. The means of the MAS observed in the track test (15.8 +/- 1.9 km h-1) and in the treadmill test (15.9 +/- 2.6 km h-1) were not significantly different (P > 0.10). The mean of the shuttle test MAS (13.1 +/- 1 km h-1) was significantly lower (P < 0.01) than those of the other tests. However, the MAS of the shuttle test and track test are linked. The equation for linear regression between MAS values in these two tests is MAStrack = 1.81 x MASshuttle -7.86 (r = 0.91), allowing estimation of one of these MAS values when the other is known. Thus these values may be used within diversified training.

  19. The Fourth Gravity Test and Quintessence Matter Field

    CERN Document Server

    Liu, Molin; Yu, Fei; Gui, Yuanxing

    2010-01-01

    After the previous work on gravitational frequency shift, light deflection (arXiv:1003.5296) and perihelion advance (arXiv:0812.2332), we calculate carefully the fourth gravity test, i.e. radar echo delay in a central gravity field surrounded by static free quintessence matter, in this paper. Through the Lagrangian method, we find the influence of the quintessence matter on the time delay of null particle is presence by means of an additional integral term. When the quintessence field vanishes, it reduces to the usual Schwarzschild case naturally. Meanwhile, we also use the data of the Viking lander from the Mars and Cassini spacecraft to Saturn to constrain the quintessence field. For the Viking case, the field parameter $\\alpha$ is under the order of $10^{-9}$. However, $\\alpha$ is under $10^{-18}$ for the Cassini case.

  20. The fourth gravity test and quintessence matter field

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Molin; Yu, Benhai [Xinyang Normal University, College of Physics and Electronic Engineering, Xinyang (China); Yu, Fei; Gui, Yuanxing [Dalian University of Technology, School of Physics and Optoelectronic Technology, Dalian (China)

    2010-06-15

    After the previous work on gravitational frequency shift, light deflection (Eur. Phys. J. C 59: 107-116, 2009) and perihelion advance (Eur. Phys. J. C 60: 175-179, 2009), we calculate carefully the fourth gravity test, i.e. radar echo delay in a central gravity field surrounded by static free quintessence matter, in this paper. Through the Lagrangian method, we find the influence of the quintessence matter on the time delay of null particle is presence by means of an additional integral term. When the quintessence field vanishes, it reduces to the usual Schwarzschild case naturally. Meanwhile, we also use the data of the Viking lander from the Mars and Cassini spacecraft to Saturn to constrain the quintessence field. For the Viking case, the field parameter {alpha} is under the order of 10{sup -9}. However, {alpha} is under 10{sup -18} for the Cassini case. (orig.)

  1. Test field for airborne laser scanning in Finland

    Science.gov (United States)

    Ahokas, E.; Kaartinen, H.; Kukko, A.; Litkey, P.

    2014-11-01

    Airborne laser scanning (ALS) is a widely spread operational measurement tool for obtaining 3D coordinates of the ground surface. There is a need for calibrating the ALS system and a test field for ALS was established at the end of 2013. The test field is situated in the city of Lahti, about 100 km to the north of Helsinki. The size of the area is approximately 3.5 km × 3.2 km. Reference data was collected with a mobile laser scanning (MLS) system assembled on a car roof. Some streets were measured both ways and most of them in one driving direction only. The MLS system of the Finnish Geodetic Institute (FGI) consists of a navigation system (NovAtel SPAN GNSS-IMU) and a laser scanner (FARO Focus3D 120). In addition to the MLS measurements more than 800 reference points were measured using a Trimble R8 VRS-GNSS system. Reference points are along the streets, on parking lots, and white pedestrian crossing line corners which can be used as reference targets. The National Land Survey of Finland has already used this test field this spring for calibrating their Leica ALS-70 scanner. Especially it was easier to determine the encoder scale factor parameter using this test field. Accuracy analysis of the MLS points showed that the point height RMSE is 2.8 cm and standard deviation is 2.6 cm. Our purpose is to measure both more MLS data and more reference points in the test field area to get a better spatial coverage. Calibration flight heights are planned to be 1000 m and 2500 m above ground level. A cross pattern, southwest-northeast and northwest-southeast, will be flown both in opposite directions.

  2. Deep Borehole Field Test Research Activities at LBNL

    Energy Technology Data Exchange (ETDEWEB)

    Dobson, Patrick [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Tsang, Chin-Fu [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Kneafsey, Timothy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Borglin, Sharon [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Piceno, Yvette [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Andersen, Gary [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Nakagawa, Seiji [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Nihei, Kurt [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rutqvist, Jonny [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Doughty, Christine [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Reagan, Matthew [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-08-19

    The goal of the U.S. Department of Energy Used Fuel Disposition’s (UFD) Deep Borehole Field Test is to drill two 5 km large-diameter boreholes: a characterization borehole with a bottom-hole diameter of 8.5 inches and a field test borehole with a bottom-hole diameter of 17 inches. These boreholes will be used to demonstrate the ability to drill such holes in crystalline rocks, effectively characterize the bedrock repository system using geophysical, geochemical, and hydrological techniques, and emplace and retrieve test waste packages. These studies will be used to test the deep borehole disposal concept, which requires a hydrologically isolated environment characterized by low permeability, stable fluid density, reducing fluid chemistry conditions, and an effective borehole seal. During FY16, Lawrence Berkeley National Laboratory scientists conducted a number of research studies to support the UFD Deep Borehole Field Test effort. This work included providing supporting data for the Los Alamos National Laboratory geologic framework model for the proposed deep borehole site, conducting an analog study using an extensive suite of geoscience data and samples from a deep (2.5 km) research borehole in Sweden, conducting laboratory experiments and coupled process modeling related to borehole seals, and developing a suite of potential techniques that could be applied to the characterization and monitoring of the deep borehole environment. The results of these studies are presented in this report.

  3. Latex agglutination test for field diagnosis of haemorrhagic septicaemia

    Directory of Open Access Journals (Sweden)

    Lily Natalia

    2002-10-01

    Full Text Available Pasteurella multocida is bacterial pathogens that cause haemorrhagic septicaemia (HS in cattle and buffaloes. Various tests have been used to differentiate types of P. multocida, as well as to diagnose this specific disease. A latex agglutination test has been developed for the detection of P. multocida B:2 which is the causal agent of HS. This test is a rapid and simple test suitable for local laboratorium to diagnose HS cases in the field. A heat stable antigen consisting of mainly lipopolysaccharide (LPS extract of formalin killed P. multocida 0019 was used to produce specific antibody against P. multocida B:2. The antiboy was then used to sensitise latex particles. Latex agglutination test have been used to screen some P. multocida field isolates and this test have been proven to be specific, simple and easy to be used in detecting P. multocida B:2. The specificity is due to antibodies recognising LPS or LPS protein complexes. Sensitised latex was stable at 4° C for at least12 months. This test should be used as an aid to diagnosis and employed principally to confirm and support clinical and post mortem findings of HS.

  4. Field Tests and Simulation of Lion-Head River Bridge

    Directory of Open Access Journals (Sweden)

    Yao-Min Fang

    2007-01-01

    Full Text Available Lion-Head River Bridge is a twin bridge in parallel position. The east-bounded was designed and constructed as a traditional prestress concrete box girder bridge with pot bearings; and the west-bounded was installed with seismic isolation devices of lead rubber bearings. The behavior of the isolated bridge is compared with that of the traditional bridge through several field tests including the ambient vibration test, the force vibration test induced by shakers, the free vibration test induced by a push and fast release system, and the truck test. The bridges suffered from various extents of damage due to the Chi-Chi and the Chi-I earthquakes of great strength during the construction and had been retrofitted. The damage was reflected by the change of the bridges' natural frequencies obtained from the ambient vibration tests. The models of the two bridges are simulated by the finite element method based on the original design drawings. Soil-structure interaction was also scrutinized in this study. The simulation was then modified based on the results from the field tests. Dynamic parameters of bridges are identified and compared with those from theoretical simulation. The efficiency is also verified to be better for an isolated bridge.

  5. The effect of performance feedback on cardiorespiratory fitness field tests.

    Science.gov (United States)

    Metsios, G S; Flouris, A D; Koutedakis, Y; Theodorakis, Y

    2006-06-01

    We investigated the effects of performance feedback (PF) on predicting maximal oxygen uptake (VO2 max) using the 20 m Multistage Shuttle Run Test (MST) and 20 m Square Shuttle Test (SST). The agreement between these two field tests in relation to laboratory VO2 max was also examined. Forty healthy males (age: 21.5+/-2.3; BMI: 23.7+/-2.0) randomly performed four indirect VO2 max tests; that is the MST and SST, as well as a modified version of MST (MSTMD) and SST (SSTMD). During MST and SST subjects received PF with respect to both test stage and running pace. In contrast, MSTMD and SSTMD incorporated auditory feedback which solely emitted signals regulating the running pace. Participants also performed a laboratory VO2 max treadmill test (TT). ANOVA demonstrated significant mean predicted VO2 max decrements in both MSTMD (pmax, the '95% limits of agreement' analysis indicated errors equal to 3.6+/-9.6 and 1.4+/-10.3 ml kg-1 min-1 with coefficients of variation of +/-10.0% and +/-10.9%, for MST and MSTMD, respectively. The corresponding '95% limits of agreement' values for SST and SSTMD were 0.1+/-5.0 and -1.1+/-6.1 ml kg-1 min-1 with coefficients of variation of +/-5.4% and +/-6.7%, respectively. It is concluded that the application of PF leads to superior field testing performances.

  6. Investigation of Microseismicity Triggered by Raised Pore Pressure through Laboratory CO2 Injection Tests in Berea Sandstone

    Science.gov (United States)

    Lee, S.; Chang, C.

    2014-12-01

    One of the critical problems for carbon dioxide capture and storage projects is the occurrence of microseismicity due to increased pore pressure during CO2 injection. The mechanism of microseismicity can be explained by the notion that the injection-induced pore pressure increase can potentially alter the reservoir rock in the form of either creating fractures or triggering slip on pre-existing discontinuities by reducing the effective normal stress. Therefore, it is important to estimate the critical pore pressure (Pcr) to prevent excessive seismicity. The purpose of this study is to attempt to simulate the microseismicity induced from increased pore pressure by CO2 injection into Berea sandstone. Cylindrical specimens were saw-cut at 30° from the specimen axis. Specimens were either dry or saturated by tap water. The frictional coefficients of the fractures were determined from triaxial shear tests to be 0.71 (dry) and 0.65 (water-saturated). With the frictional coefficients known, we then injected CO2 (either gaseous of liquid state) into the specimens (either dry or water-saturated) subjected to triaxial stress conditions. Under the conditions of constant confining pressures and axial stresses, we increased pore pressure in steps by injecting CO2 using a syringe pump. We monitored shear slip along the fracture using axial LVDTs and microseismicity using an acoustic emission sensor. The critical pore pressure that would initiate shear slip along the fracture was calculated from the Coulomb friction law. When CO2 was injected into dry specimens, shear slip and associated microseismicity started to occur at the pore pressure levels exactly estimated from the Coulomb theory. However, when CO2 (both gaseous and liquid states) was injected into water-saturated specimens, the same were initiated at pore pressures slightly higher (by 1.2-3.7 MPa) than that estimated from the Coulomb friction law. These results suggest that the presence of water and associated water

  7. Field Testing of a Portable Radiation Detector and Mapping System

    Energy Technology Data Exchange (ETDEWEB)

    Hofstetter, K.J. [Westinghouse Savannah River Company, AIKEN, SC (United States); Hayes, D.W.; Eakle, R.F.

    1998-03-01

    Researchers at the Savannah River Site (SRS) have developed a man- portable radiation detector and mapping system (RADMAPS) which integrates the accumulation of radiation information with precise ground locations. RADMAPS provides field personnel with the ability to detect, locate, and characterize nuclear material at a site or facility by analyzing the gamma or neutron spectra and correlating them with position. the man-portable field unit records gamma or neutron count rate information and its location, along with date and time, using an embedded Global Positioning System (GPS). RADMAPS is an advancement in data fusion, integrating several off-the-shelf technologies with new computer software resulting in a system that is simple to deploy and provides information useful to field personnel in an easily understandable form. Decisions on subsequent actions can be made in the field to efficiently use available field resources. The technologies employed in this system include: recording GPS, radiation detection (typically scintillation detectors), pulse height analysis, analog-to-digital converters, removable solid-state (Flash or SRAM) memory cards, Geographic Information System (GIS) software and personal computers with CD-ROM supporting digital base maps. RADMAPS includes several field deployable data acquisition systems designed to simultaneously record radiation and geographic positions. This paper summarizes the capabilities of RADMAPS and some of the results of field tests performed with the system.

  8. Prototype Engineered Barrier System Field Test (PEBSFT); Final report

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, A.L. [ed.; Buscheck, T.; Carlson, R.; Daily, W.; Lee, K.; Lin, Wunan; Mao, Nai-hsien; Ueng, Tzou-Shin; Wang, H.; Watwood, D.

    1991-08-01

    This final report represents a summary of data and interpretations obtained from the Prototype Engineered Barrier System Field Test (PEBSFT) performed in G-Tunnel within the Nevada Test Site. The PEBSFT was conducted to evaluate the applicability of measurement techniques, numerical models, and procedures developed for future field tests that will be conducted in the Exploratory Studies Facilities (ESF) at Yucca Mountain. The primary objective of the test was to provide a basis for determining whether tests planned for the ESF have the potential to be successful. Chapter 1 on high frequency electromagnetic tomography discusses the rock mass electromagnetic permittivity and attenuation rate changes that were measured to characterize the water distribution in the near field of a simulated waste container. The data are used to obtain quantitative estimates of how the moisture content in the rock mass changes during heating and to infer properties of the spatial variability of water distribution, leading to conclusions about the role of fractures in the system. Chapter 2 discusses the changes in rock moisture content detected by the neutron logging probe. Chapter 3 permeability tests discusses the characterization of the in-situ permeability of the fractured tuff around the borehole. The air permeability testing apparatus, the testing procedures, and the data analysis are presented. Chapter 4 describes the moisture collection system installed in the heater borehole to trap and measure the moisture volumes. Chapter 5 describes relative humidity measurements made with the thermocouple psychrometer and capacitance sensors. Chapter 6 discusses gas pressure measurements in the G-Tunnel, addressing the calibration and installation of piezoresistive-gaged transducers. Chapter 7 describes the calibration and installation of thermocouples for temperature measurements. Chapter 8 discusses the results of the PEBSFT.

  9. Comparison of two aerobic field tests in young tennis players.

    Science.gov (United States)

    Fargeas-Gluck, Marie-Agnès; Léger, Luc A

    2012-11-01

    This study compares the maximal responses of a new aerobic tennis field test, the NAVTEN to a known aerobic field test, often used with young tennis players, that is, the continuous multistage 20-m shuttle run test (20-m SRT). The NAVTEN is an intermittent (1-minute/1-minute) multistage test with side-to-side displacements and ball hitting. Ten young elite tennis players aged 12.9 ± 0.3 (mean ± SD) randomly performed both tests and were continuously monitored for heart rate (HR) and oxygen uptake (V[Combining Dot Above]O2) using the Vmax ST (Sensormedics). The 20-m SRT and NAVTEN show similar HRpeak (202 ± 6.1 vs. 208 ± 9.5, respectively) and V[Combining Dot Above]O2peak (54.2 ± 5.9 vs. 54.9 ± 6.0 ml·kg·min). Pearson correlations between both tests were 0.88 and 0.92 for V[Combining Dot Above]O2peak and maximal speed, respectively. The NAVTEN yielded V[Combining Dot Above]O2peak values that are typical for active subjects of that age and are similar to the 20-m SRT supporting its use to measure aerobic fitness of young tennis players in specific and entertaining field conditions. The fact that two-thirds of the tennis players achieved a different ranking (±1 rank) with the NAVTEN and the 20-m SRT suggests that the NAVTEN may be more specific than the 20-m SRT to assess aerobic fitness of tennis players. From a practical point of view, the NAVTEN test is more specific and pedagogical for young tennis players even though both tests yield similar maximal values.

  10. Practical experience applied to the design of injection and sample manifolds to perform in-place surveillance tests according to ANSI/ASME N-510

    Energy Technology Data Exchange (ETDEWEB)

    Banks, E.M.; Wikoff, W.O.; Shaffer, L.L. [NUCON International, Inc., Columbus, OH (United States)

    1997-08-01

    At the current level of maturity and experience in the nuclear industry, regarding testing of air treatment systems, it is now possible to design and qualify injection and sample manifolds for most applications. While the qualification of sample manifolds is still in its infancy, injection manifolds have reached a mature stage that helps to eliminate the {open_quotes}hit or miss{close_quotes} type of design. During the design phase, manifolds can be adjusted to compensate for poor airflow distribution, laminar flow conditions, and to take advantage of any system attributes. Experience has shown that knowing the system attributes before the design phase begins is an essential element to a successful manifold design. The use of a spreadsheet type program commonly found on most personal computers can afford a greater flexibility and a reduction in time spent in the design phase. The experience gained from several generations of manifold design has culminated in a set of general design guidelines. Use of these guidelines, along with a good understanding of the type of testing (theoretical and practical), can result in a good manifold design requiring little or no field modification. The requirements for manifolds came about because of the use of multiple banks of components and unconventional housing inlet configurations. Multiple banks of adsorbers and pre and post HEPA`s required that each bank be tested to insure that each one does not exceed a specific allowable leakage criterion. 5 refs., 5 figs., 1 tab.

  11. A PILOT STUDY COMPARING TWO FIELD TESTS WITH THE TREADMILL RUN TEST IN SOCCER PLAYERS

    Directory of Open Access Journals (Sweden)

    Abdul Rashid Aziz

    2005-06-01

    Full Text Available This study compares the performances obtained during soccer-specific field tests of the 20 m multistage shuttle run test (MST and the Yo-Yo intermittent endurance test (YIET, with the measured maximal oxygen uptake (VO2max obtained in both field tests as well as that obtained in the traditional test of running to exhaustion on a treadmill (TRT, in young trained soccer players. Twenty-one National-level youth players performed, in random order, the MST and YIET to determine the relationship between the two field tests. From these, eight randomly chosen players performed their field tests as well as a TRT, equipped with an ambulatory gas exchange measurement device. Pearson correlation coefficient analysis showed that the players' performance (i.e. distance covered in the MST and YIET was correlated (r = 0.65, p 0.05. In contrast, significant correlations were observed between the players' performance in the MST with the measured VO2max obtained in the same MST and in the YIET (both p < 0.05; and attained almost statistical significance with the measured VO2max in the TRT (p = 0.06. The lack of association between distances covered in the YIET with all the measured VO2max values suggest that measured VO2max per se may not be suitable to characterize soccer players' intermittent endurance performance. In comparison with the MST, the YIET may be a more favourable field-based assessment of soccer player's endurance performance

  12. Testing and comparison of four ionic tracers to measure stream flow loss by multiple tracer injection

    Science.gov (United States)

    Zellweger, G.W.

    1994-01-01

    An injectate containing lithium, sodium, chloride and bromide was added continuously at five sites along a 507 m study reach of St Kevin Gulch, Lake County, Colorado to determine which sections of the stream were losing water to the stream bed and to ascertain how well the four tracers performed. The acidity of the stream (pH 3.6) made it possible for lithium and sodium, which are normally absorbed by ion exchange with stream bed sediment, to be used as conservative tracers. Net flow losses as low as 0.81 s-1, or 8% of flow, were calculated between measuring sites. By comparing the results of simultaneous injection it was determined whether subsections of the study reach were influent or effluent. Evaluation of tracer concentrations along 116 m of stream indicated that all four tracers behaved conservatively. Discharges measured by Parshall flumes were 4-18% greater than discharges measured by tracer dilution. -from Author

  13. A possible field test for marine cloud brightening geoengineering. A possible field test for marine cloud brightening geoengineering

    Science.gov (United States)

    Gadian, A.; Wood, R.; Coe, H.; Latham, J.

    2011-12-01

    A possible field test for marine cloud brightening geoengineering. Abstract: The Marine Cloud Brightening (MCB) geoengineering technique (Latham et al 2008) hypothesizes that seeding marine stratocumulus clouds with copious quantities of roughly monodisperse sub-micrometre seawater particles can enhance the cloud droplet number concentration and increase cloud albedo. Here, we propose a set of field tests to critically assess the efficacy of the MCB geoengineering proposal over a limited area. The tests are de minimus with respect to their climate effects. The tests involve three phases, with increasing logistical complexity, each of which is designed to test one or more important components of the cloud brightening scheme. Each involves the introduction and monitoring of controlled aerosol perturbations from one or more ship-based seeding platforms up to a limited area of 100x100 km2. A suite of observational platforms of increasing number and complexity, including aircraft, ships and satellites, will observe the aerosol plume and in the later experiments the cloud and albedo responses to the aerosol perturbations. These responses must include the necessary cloud physical and chemical processes which determine the efficacy of the cloud brightening scheme. Since these processes are also central to the broader problem of aerosol-cloud-climate interactions, such field tests would have significant benefits for climate science in addition to providing a critical test of the MCB hypothesis. Such field experiments should be designed and conducted in an objective manner within the framework of emerging geoengineering research governance structures. Reference: Latham J. et al.. (2008) Global temperature stabilization via controlled albedo enhancement of low-level maritime clouds. Phil. Trans. R. Soc. A doi:10.1098/rsta.2008.0137

  14. Large Field Photogrammetry Techniques in Aircraft and Spacecraft Impact Testing

    Science.gov (United States)

    Littell, Justin D.

    2010-01-01

    The Landing and Impact Research Facility (LandIR) at NASA Langley Research Center is a 240 ft. high A-frame structure which is used for full-scale crash testing of aircraft and rotorcraft vehicles. Because the LandIR provides a unique capability to introduce impact velocities in the forward and vertical directions, it is also serving as the facility for landing tests on full-scale and sub-scale Orion spacecraft mass simulators. Recently, a three-dimensional photogrammetry system was acquired to assist with the gathering of vehicle flight data before, throughout and after the impact. This data provides the basis for the post-test analysis and data reduction. Experimental setups for pendulum swing tests on vehicles having both forward and vertical velocities can extend to 50 x 50 x 50 foot cubes, while weather, vehicle geometry, and other constraints make each experimental setup unique to each test. This paper will discuss the specific calibration techniques for large fields of views, camera and lens selection, data processing, as well as best practice techniques learned from using the large field of view photogrammetry on a multitude of crash and landing test scenarios unique to the LandIR.

  15. The Fourth Gravity Test and Quintessence Matter Field

    OpenAIRE

    Liu, Molin; Yu, Benhai; Yu, Fei; Gui, Yuanxing

    2010-01-01

    After the previous work on gravitational frequency shift, light deflection (arXiv:1003.5296) and perihelion advance (arXiv:0812.2332), we calculate carefully the fourth gravity test, i.e. radar echo delay in a central gravity field surrounded by static free quintessence matter, in this paper. Through the Lagrangian method, we find the influence of the quintessence matter on the time delay of null particle is presence by means of an additional integral term. When the quintessence field vanishe...

  16. Overspinning BTZ black holes with test particles and fields

    Science.gov (United States)

    Düztaş, Koray

    2016-12-01

    It has been claimed that in a test of an asymptotically anti-de Sitter version of weak cosmic censorship conjecture by attempting to overspin a Bañados, Teitelboim, and Zanelli (BTZ) black hole with test particles, one finds that it is not possible to spin up the black hole past its extremal limit. The result of this analysis is restricted to the case where the initial black hole is extremal. We extend this analysis to find that massive test particles can overspin the black hole, if we start with a nearly extremal black hole, instead. We also consider the interaction of the BTZ black hole with test fields. We show that overspinning of nearly extremal black holes is possible whether or not there is super-radiance for the field. If there is super-radiance, overspinning occurs in a narrow range of frequencies bounded below by the super-radiant limit. However, if there is no super-radiance for the field, overspinning becomes generic and also applies to extremal black holes. This is in analogy with the Kerr case.

  17. Gas monitoring during the CO2 back production field test at the Ketzin pilot site

    Science.gov (United States)

    Szizybalski, Alexandra; Zimmer, Martin; Kujawa, Christian; Erzinger, Jörg

    2015-04-01

    The GFZ German Research Centre for Geosciences operates Europe's first on-shore CO2 storage site in Ketzin, a small town near Berlin. From June 2008 until August 2013 about 67 kt of CO2 were injected into Upper Triassic sandstones in 630 to 650 m depth. The injection phase ended with an experiment to evaluate the influence of additives on CO2 storage. During this experiment 32 t N2 and 613 t CO2 were co-injected into the borehole over a period of 25 days followed by the final injection of 66 t pure CO2. At the beginning of the experiment 10,000 l (10 Nm3) Kr were pumped into the borehole, to separate the previous pure CO2 and the CO2-N2 mixture. For the same reason, CO2 with a different isotopic composition (δ13C = -3.4±0.2o instead of δ13C = -30.6±0.4) was used for the first 548 t of the total 613 t. To demonstrate that the stored CO2 is retrievable a field test was carried out in October 2014 during a period of two weeks. Of interest, in this context, is the composition of the back-produced gas which delivers key information on possible interactions between the CO2, formation fluid and rocks. In total 240 t of gas were produced via the former injection well. The flow rates ranged between 800 and 3,200 kg gas/h. The gas was sampled after the gas/water separator and continuously analysed using a mass spectrometer, a gas chromatograph and a photoacoustic sensor, thus covering all gas components and concentrations. In addition, gas samples were collected for stable carbon isotopes investigations in the laboratory. Preliminary results show that the produced gas consists of > 97% CO2 plus mainly N2. The N2 was detected from the beginning, although the injection in 2013 ended with pure CO2. The N2 concentration decreased from about 3% to 1% during the two weeks of the experiment. In addition to these major components CH4, CO and H2 (up to 0.01%) as well as Kr and SF6 (up to 0.001%, both were used as tracers in 2013) were detected. The gas composition of natural

  18. Single-well injection-withdrawal tests (SWIW). Literature review and scoping calculations for homogeneous crystalline bedrock conditions

    Energy Technology Data Exchange (ETDEWEB)

    Nordqvist, Rune; Gustafsson, Erik [Geosigma AB, Uppsala (Sweden)

    2002-08-01

    This report describes a literature review and scoping calculations carried out in order to test the feasibility of using SWIW (Single Well Injection Withdrawal) tracer experiments for expected hydraulic conditions in Swedish bedrock. The motivation for using SWIW tests in the site investigation programme is that extensive cross-hole tracer tests may not be possible and that such SWIW tests are more or less the only available single-hole tracer test method. The scoping calculations are aimed at establishing conditions under which SWIW tests should be feasible, by studying experimental attributes such as expected bedrock properties (transmissivity, porosity, etc), ambient hydraulic gradients, duration of various experimental phases, hydraulic injection pressure and parameter identification possibilities. Particular emphasis has been placed on the use of the dilution probe as an experimental device for SWIW, although the scoping results also should be considered applicable to any experimental equipment approach. The results from the scoping calculations indicate that SWIW tests using the dilution probe are feasible under the required experimental and site requirements for the forthcoming site investigations programme. The characteristic flow reversibility feature inherent in SWIW tests causes some differences compared with cross-hole tracer tests. Advective parameters (i.e. mobile porosity, dispersivity) are generally more difficult to identify/estimate and the same may also be said about equilibrium sorption. Time-dependent processes, on the other hand, generally benefit from the flow reversibility, in principle even in the presence of heterogeneity. However, it may not always be possible to identify time-dependent processes, such as matrix diffusion, for expected conditions in Swedish bedrock. Experimental aims may be allowed to vary depending on the specific conditions (transmissivity, hydraulic gradient, etc.) in the tested borehole section.

  19. Field and temperature dependence of space charge injection in a silicone rubber

    Science.gov (United States)

    Rain, P.; Nguyen, D. H.; Sylvestre, A.; Rowe, S.

    2009-12-01

    The generation of space charges in a silicone elastomer has been characterized under dc voltage as a function of the temperature using the laser induced pressure pulse (LIPP) method. The analysis of the LIPP spectra has been detailed thanks to acoustical considerations, taking into account the reflection, attenuation and dispersion of the pressure wave. Both heterocharges and homocharges have been observed depending on the field magnitude (5 to 20 × 106 V m-1), polarization duration and temperature (20, 40 or 60 °C). With temperature increasing, charges are observed at lower fields. Heterocharges appear in less stressed conditions. Then, homocharges take the place of these heterocharges. Positive homocharges are observed in lower stressed conditions than negative homocharges. Mobility of these charges has not been observed below 60 °C.

  20. SMART wind turbine rotor. Design and field test

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Jonathan Charles; Resor, Brian Ray; Paquette, Joshua A.; White, Jonathan Randall

    2014-01-01

    The Wind Energy Technologies department at Sandia National Laboratories has developed and field tested a wind turbine rotor with integrated trailing-edge flaps designed for active control of rotor aerodynamics. The SMART Rotor project was funded by the Wind and Water Power Technologies Office of the U.S. Department of Energy (DOE) and was conducted to demonstrate active rotor control and evaluate simulation tools available for active control research. This report documents the design, fabrication, and testing of the SMART Rotor. This report begins with an overview of active control research at Sandia and the objectives of this project. The SMART blade, based on the DOE / SNL 9-meter CX-100 blade design, is then documented including all modifications necessary to integrate the trailing edge flaps, sensors incorporated into the system, and the fabrication processes that were utilized. Finally the test site and test campaign are described.

  1. An investigation of flow-limited field-injection electrostatic spraying (FFESS) and its applications to thin film deposition

    Science.gov (United States)

    Singh, Ravindra Pratap

    Electrostatic spraying is the process of controlled disruption of a liquid surface due to excess surface charge density. The technique has found applications in a wide range of fields from agricultural sprays to fuel injectors to colloidal thrusters for space vehicle propulsion. Over the past 20 years, the technique has been intensely studied in material processing for synthesis of ceramic and metal powders, nanoparticles and thin films. The importance of the technique lies in its simple setup, high deposition efficiency, and ambient atmosphere operation. In conventional electrostatic spraying (CESS), one uses a conducting nozzle to charge the liquid, mostly by induction charging. CESS is therefore restricted to the single jet mode of spraying which occurs at low spray currents. It lacks stability and reproducibility in the high current, multiple jet regime, which can generate much finer sprays. In flow-limited field-injection electrostatic spraying (FFESS), one uses a field-injection electrode to stably and controllably inject higher currents into the liquid, a la Fowler-Nordheim, using an otherwise insulating nozzle. This way, it is possible to stably electrospray in the multiple jet mode. In addition to producing much finer sprays, the multi-jet mode atomizes liquids at higher rates, and spreads the spray over a wider region and more uniformly than single jet sprays, thus paving way for large-area uniform thin film deposition. A simple yet comprehensive theory is formulated to describe the multi jet formation. The theory, which is based on the energy minimization principle, takes into account, for the first time, the interactions between charged jets which leads to saturation in the number of jets at high spray currents. The possibility of using an array of nozzles to obtain uniform large-area high-throughput thin film deposition is also investigated. A large number of FFESS nozzles with alternating positive and negative polarities arranged in a periodic 2

  2. Local and regional seismic response to injection and production at the Salton Sea geothermal field, southern California

    Science.gov (United States)

    Lajoie, L. J.; Brodsky, E. E.

    2011-12-01

    California hosts both the largest geothermal resource capacity and highest seismicity rate in the nation. With plans to increase geothermal output, and proven earthquake triggering in the vicinity of geothermal power plants worldwide, it is important to determine the local and regional effects of geothermal power production. This study focuses on relating the volume of fluid extracted from and re-injected into wells at the Salton Sea geothermal field (SSGF) in Southern California to local seismicity rate and increased probability of larger events on nearby faults such as the San Andreas and Imperial faults. Seismic data is obtained from the publicly available Advanced National Seismic System (ANSS) catalog and SSGF injection and production data from the State of California Department of Conservation. We identify triggered earthquakes in the catalog by modeling seismicity in a 15km radius around the SSGF according to an Epidemic-Type Aftershock Sequence (ETAS) method. The model seeks to fit the cumulative seismicity curve from our dataset by optimizing five seismic parameters in accordance with Gutenberg-Richter and Omori's law. The modeled curve is then removed from the dataset to isolate the non-ETAS, or production-triggered, signal. We then formulate a constitutive law to relate the seismicity rate to the driving stress (i.e. volumetric strain in the reservoir). Defining the local stressing rate provides a tool for predicting the effects that production has on regional seismicity rates. The largest spike in SSGF net production volume over the past 30 years is accompanied by the one of the largest increases in both seismicity rate and moment release within the geothermal field. This indicates a direct coupling between net fluid production volume (volume extracted minus volume re-injected) and seismicity rate and cumulative seismic moment in the field. Three dimensional plots of hypocentral earthquake locations show that seismicity is concentrated on an

  3. Field Test of Wake Steering at an Offshore Wind Farm

    Energy Technology Data Exchange (ETDEWEB)

    Fleming, Paul; Annoni, Jennifer; Shah, Jigar J.; Wang, Linpeng; Ananthan, Shreyas; Zhang, Zhijun; Hutchings, Kyle; Wang, Peng; Chen, Weiguo; Chen, Lin

    2017-02-06

    In this paper, a field test of wake steering control is presented. The field test is the result of a collaboration between the National Renewable Energy Laboratory (NREL) and Envision Energy, a smart energy management company and turbine manufacturer. In the campaign, an array of turbines within an operating commercial offshore wind farm in China have the normal yaw controller modified to implement wake steering according to a yaw control strategy. The strategy was designed using NREL wind farm models, including a computational fluid dynamics model, SOWFA, for understanding wake dynamics and an engineering model, FLORIS, for yaw control optimization. Results indicate that, within the certainty afforded by the data, the wake-steering controller was successful in increasing power capture, by amounts similar to those predicted from the models.

  4. Barriers and missed opportunities to HIV testing among injection drug users in two Mexico--US border cities.

    Science.gov (United States)

    Moyer, Laura B; Brouwer, Kimberley C; Brodine, Stephanie K; Ramos, Rebeca; Lozada, Remedios; Cruz, Michelle Firestone; Magis-Rodriguez, Carlos; Strathdee, Steffanie A

    2008-01-01

    Despite increasing HIV prevalence in cities along the Mexico--US border, HIV testing among high-risk populations remains low. We sought to identify barriers associated with HIV testing among injection drug users (IDUs) in Tijuana and Ciudad Juarez, the two largest Mexican border cities located across from San Diego, California and El Paso, Texas, respectively. In 2005, 222 IDUs in Tijuana and 205 IDUs in Ciudad Juarez were recruited by respondent-driven sampling and administered a questionnaire to collect socio-demographic, behavioural and HIV testing history data. Blood samples were provided for serological testing of HIV, hepatitis C virus (HCV) and syphilis. Only 38% and 30% of respondents in Tijuana and Ciudad Juarez, respectively, had ever had an HIV test. The factors independently associated with never having been tested for HIV differed between the two sites, except for lack of knowledge on HIV transmission, which was independently associated in both locales. Importantly, 65% of those who had never been tested for HIV in both cities experienced at least one missed opportunity for voluntary testing, including medical visits, drug treatment and spending time in jail. Among this high-risk IDU population we found HIV testing to be low, with voluntary testing in public and private settings utilised inadequately. These findings underscore the need to expand voluntary HIV education and testing and to integrate it into services and locales frequented by IDUs in these Mexico--US border cities.

  5. FIELD TEST PROGRAM TO DEVELOP COMPREHENSIVE DESIGN, OPERATING, AND COST DATA FOR MERCURY CONTROL SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Michael D. Durham

    2004-10-01

    PG&E NEG Salem Harbor Station Unit 1 was successfully tested for applicability of activated carbon injection as a mercury control technology. Test results from this site have enabled a thorough evaluation of mercury control at Salem Harbor Unit 1, including performance, estimated cost, and operation data. This unit has very high native mercury removal, thus it was important to understand the impacts of process variables on native mercury capture. The team responsible for executing this program included plant and PG&E headquarters personnel, EPRI and several of its member companies, DOE, ADA, Norit Americas, Inc., Hamon Research-Cottrell, Apogee Scientific, TRC Environmental Corporation, Reaction Engineering, as well as other laboratories. The technical support of all of these entities came together to make this program achieve its goals. Overall the objectives of this field test program were to determine the mercury control and balance-of-plant impacts resulting from activated carbon injection into a full-scale ESP on Salem Harbor Unit 1, a low sulfur bituminous-coal-fired 86 MW unit. It was also important to understand the impacts of process variables on native mercury removal (>85%). One half of the gas stream was used for these tests, or 43 MWe. Activated carbon, DARCO FGD supplied by NORIT Americas, was injected upstream of the cold side ESP, just downstream of the air preheater. This allowed for approximately 1.5 seconds residence time in the duct before entering the ESP. Conditions tested in this field evaluation included the impacts of the Selective Non-Catalytic Reduction (SNCR) system on mercury capture, of unburned carbon in the fly ash, of adjusting ESP inlet flue gas temperatures, and of boiler load on mercury control. The field evaluation conducted at Salem Harbor looked at several sorbent injection concentrations at several flue gas temperatures. It was noted that at the mid temperature range of 322-327 F, the LOI (unburned carbon) lost some of its

  6. The virtual fields method applied to spalling tests on concrete

    Directory of Open Access Journals (Sweden)

    Forquin P.

    2012-08-01

    Full Text Available For one decade spalling techniques based on the use of a metallic Hopkinson bar put in contact with a concrete sample have been widely employed to characterize the dynamic tensile strength of concrete at strain-rates ranging from a few tens to two hundreds of s−1. However, the processing method mainly based on the use of the velocity profile measured on the rear free surface of the sample (Novikov formula remains quite basic and an identification of the whole softening behaviour of the concrete is out of reach. In the present paper a new processing method is proposed based on the use of the Virtual Fields Method (VFM. First, a digital high speed camera is used to record the pictures of a grid glued on the specimen. Next, full-field measurements are used to obtain the axial displacement field at the surface of the specimen. Finally, a specific virtual field has been defined in the VFM equation to use the acceleration map as an alternative ‘load cell’. This method applied to three spalling tests allowed to identify Young’s modulus during the test. It was shown that this modulus is constant during the initial compressive part of the test and decreases in the tensile part when micro-damage exists. It was also shown that in such a simple inertial test, it was possible to reconstruct average axial stress profiles using only the acceleration data. Then, it was possible to construct local stress-strain curves and derive a tensile strength value.

  7. Insight from simulations of single-well injection-withdrawal tracer tests on simple and complex fractures

    Energy Technology Data Exchange (ETDEWEB)

    Tsang, C.-F.; Doughty, C.

    2009-08-06

    The single-well injection withdrawal (SWIW) test, a tracer test utilizing only one well, is proposed as a useful contribution to site characterization of fractured rock, as well as providing parameters relevant to tracer diffusion and sorption. The usual conceptual model of flow and solute transport through fractured rock with low matrix permeability involves solute advection and dispersion through a fracture network coupled with diffusion and sorption into the surrounding rock matrix. Unlike two-well tracer tests, results of SWIW tests are ideally independent of advective heterogeneity, channeling and flow dimension, and, instead, focus on diffusive and sorptive characteristics of tracer (solute) transport. Thus, they can be used specifically to study such characteristics and evaluate the diffusive parameters associated with tracer transport through fractured media. We conduct simulations of SWIW tests on simple and complex fracture models, the latter being defined as having two subfractures with altered rock blocks in between and gouge material in their apertures. Using parameters from the Aspo site in Sweden, we calculate and study SWIW tracer breakthrough curves (BTCs) from a test involving four days of injection and then withdrawal. By examining the peak concentration C{sub pk} of the SWIW BTCs for a variety of parameters, we confirm that C{sub pk} is largely insensitive to the fracture advective flow properties, in particular to permeability heterogeneity over the fracture plane or to subdividing the flow into two subfractures in the third dimension orthogonal to the fracture plane. The peak arrival time t{sub pk} is not a function of fracture or rock properties, but is controlled by the time schedule of the SWIW test. The study shows that the SWIW test is useful for the study of tracer diffusion-sorption processes, including the effect of the so-called flow-wetted surface (FWS) of the fracture. Calculations with schematic models with different FWS values are

  8. Field-testing UV disinfection of drinking water

    Energy Technology Data Exchange (ETDEWEB)

    Gadgil, A.; Drescher, A.; Greene, D. [Lawrence Berkeley National Lab., CA (United States); Miller, P. [Natural Resources Defense Council (United States); Motau, C. [South African Center for Essential Community Services (South Africa); Stevens, F. [Durban Metro Water (South Africa)

    1997-09-01

    A recently invented device, ``UV Waterworks,`` uses ultraviolet (UV) light to disinfect drinking water. Its novel features are: low cost, robust design, rapid disinfection, low electricity use, low maintenance, high flow rate and ability to work with unpressurized water sources. The device could service a community of 1,000 persons, at an annual total cost of less than 10 US cents per person. UV Waterworks has been successfully tested in the laboratory. Limited field trials of an early version of the device were conducted in India in 1994--95. Insights from these trials led to the present design. Extended field trials of UV Waterworks, initiated in South Africa in February 1997, will be coordinated by the South African Center for Essential Community Services (SACECS), with technical and organizational support from Lawrence Berkeley National Laboratory(LBNL) and the Natural Resources Defense Council (both US). The first of the eight planned sites of the year long trial is an AIDS hospice near Durban. Durban metro Water and LBNL lab-tested a UV Waterworks unit prior to installing it at the hospice in August, 1997. The authors describe the field test plans and preliminary results from Durban.

  9. Approaching viscosity control: electrical heating of extra heavy oil as alternative to diluent injection in down hole in Cerro Negro Field, Faja Petrolifera del Orinoco

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Manuel [Petroleos de Venezuela SA, PDVSA (Venezuela)

    2011-07-01

    Electrical heating is a method used to enhance oil recovery in extra heavy oil reservoirs. This method can be used when diluent injection or other methods are not able to reduce oil viscosity sufficiently or when problems of product quality or quantity arise. The aim of this paper is to evaluate the performance of electrical heating, individually and simultaneously with injection of diluents. For this purpose, simulations were undertaken in one well with integrated electrical heating and diluent injection in Cerro Negro Field in the Orinoco oil belt, Venezuela. Results have shown that the application of both methods together is more profitable than the application of electrical heating alone. This paper demonstrated that the use of electrical heating and diluent injection combined is a valid alternative to diluent injection alone, reducing production loss.

  10. Acceptability of rapid oral fluid HIV testing among male injection drug users in Taiwan, 1997 and 2007.

    Science.gov (United States)

    Lyu, Shu-Yu; Morisky, Donald E; Yeh, Ching-Ying; Twu, Shiing-Jer; Peng, Eugene Yu-Chang; Malow, Robert M

    2011-04-01

    Rapid oral fluid HIV testing (rapid oral testing) is in the process of being adapted in Taiwan and elsewhere given its advantages over prior HIV testing methods. To guide this process, we examined the acceptability of rapid oral testing at two time points (i.e., 1997 and 2007) among one of the highest risk populations, male injection drug users (IDUs). For this purpose, an anonymous self-administered survey was completed by HIV-negative IDUs involved in the criminal justice system in 1997 (N (1)=137 parolees) and 2007 (N (2)=106 prisoners). A social marketing model helped guide the design of our questionnaire to assess the acceptability of rapid oral testing. This included assessing a new product, across four marketing dimensions: product, price, promotion, and place. Results revealed that in both 1997 and 2007, over 90% indicated that rapid oral testing would be highly acceptable, particularly if the cost was under US$6, and that a pharmacy would be the most appropriate and accessible venue for selling the rapid oral testing kits. The vast majority of survey respondents believed that the cost of rapid oral testing should be federally subsidized and that television and newspaper advertisements would be the most effective media to advertise for rapid oral testing. Both the 1997 and 2007 surveys suggested that rapid oral HIV testing would be particularly accepted in Taiwan by IDUs after release from the criminal justice system.

  11. Equivalent ambipolar carrier injection of electrons and holes with Au electrodes in air-stable field effect transistors

    Energy Technology Data Exchange (ETDEWEB)

    Kanagasekaran, Thangavel, E-mail: kanagasekaran@gmail.com, E-mail: Shimotani@m.tohoku.ac.jp, E-mail: tanigaki@m.tohoku.ac.jp; Ikeda, Susumu; Kumashiro, Ryotaro [WPI-Advanced Institute for Materials Research (WPI-AIMR), Tohoku University, 2-1-1 Katahira, Aoba, Sendai 980-8577 (Japan); Shimotani, Hidekazu, E-mail: kanagasekaran@gmail.com, E-mail: Shimotani@m.tohoku.ac.jp, E-mail: tanigaki@m.tohoku.ac.jp; Shang, Hui [Department of Physics, Graduate School of Science, Tohoku University, 6-3 Aoba, Aramaki, Aoba, Sendai 980-8578 (Japan); Tanigaki, Katsumi, E-mail: kanagasekaran@gmail.com, E-mail: Shimotani@m.tohoku.ac.jp, E-mail: tanigaki@m.tohoku.ac.jp [WPI-Advanced Institute for Materials Research (WPI-AIMR), Tohoku University, 2-1-1 Katahira, Aoba, Sendai 980-8577 (Japan); Department of Physics, Graduate School of Science, Tohoku University, 6-3 Aoba, Aramaki, Aoba, Sendai 980-8578 (Japan)

    2015-07-27

    Carrier injection from Au electrodes to organic thin-film active layers can be greatly improved for both electrons and holes by nano-structural surface control of organic semiconducting thin films using long-chain aliphatic molecules on a SiO{sub 2} gate insulator. In this paper, we demonstrate a stark contrast for a 2,5-bis(4-biphenylyl)bithiophene (BP2T) active semiconducting layer grown on a modified SiO{sub 2} dielectric gate insulator between two different modifications of tetratetracontane and poly(methyl methacrylate) thin films. Important evidence that the field effect transistor (FET) characteristics are independent of electrode metals with different work functions is given by the observation of a conversion of the metal-semiconductor contact from the Schottky limit to the Bardeen limit. An air-stable light emitting FET with an Au electrode is demonstrated.

  12. Deep Borehole Field Test Requirements and Controlled Assumptions.

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Ernest [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-07-01

    This document presents design requirements and controlled assumptions intended for use in the engineering development and testing of: 1) prototype packages for radioactive waste disposal in deep boreholes; 2) a waste package surface handling system; and 3) a subsurface system for emplacing and retrieving packages in deep boreholes. Engineering development and testing is being performed as part of the Deep Borehole Field Test (DBFT; SNL 2014a). This document presents parallel sets of requirements for a waste disposal system and for the DBFT, showing the close relationship. In addition to design, it will also inform planning for drilling, construction, and scientific characterization activities for the DBFT. The information presented here follows typical preparations for engineering design. It includes functional and operating requirements for handling and emplacement/retrieval equipment, waste package design and emplacement requirements, borehole construction requirements, sealing requirements, and performance criteria. Assumptions are included where they could impact engineering design. Design solutions are avoided in the requirements discussion. Deep Borehole Field Test Requirements and Controlled Assumptions July 21, 2015 iv ACKNOWLEDGEMENTS This set of requirements and assumptions has benefited greatly from reviews by Gordon Appel, Geoff Freeze, Kris Kuhlman, Bob MacKinnon, Steve Pye, David Sassani, Dave Sevougian, and Jiann Su.

  13. A titanium hydride gun for plasma injection into the T2-reversed field pinch device

    Science.gov (United States)

    Voronin, A. V.; Hellblom, K. G.

    1999-02-01

    A study of a plasma gun (modified Bostic type) with titanium hydride electrodes has been carried out. The total number of released hydrogen atoms was in the range 1016-1018 and the maximum plasma flow velocity was 2.5×105 m s-1. The ion density near the gun edge reached 1.8×1020 m-3 and the electron temperature was around 40 eV as estimated from probe measurements. No species other than hydrogen or titanium were seen in the plasma line radiation. The plasma injector was successfully used for gas pre-ionization in the Extrap T2 reversed-field pinch device (ohmic heating toroidal experiment (OHTE)).

  14. Simple and rapid field tests for brucellosis in livestock.

    Science.gov (United States)

    Abdoel, Theresia; Dias, Isabel Travassos; Cardoso, Regina; Smits, Henk L

    2008-08-25

    Four simple and rapid field tests for the serodiagnosis of brucellosis in cattle, goat, sheep and swine were developed. The performance of the assays was investigated using serum samples collected in Portugal from animals originating from herds with a defined sanitary status with respect to the presence of brucellosis. The sensitivity calculated for the bovine, caprine, ovine and swine Brucella lateral flow assays based on results obtained for samples collected from animals with culture confirmed brucellosis was 90%, 100%, 90% and 73%, respectively. None of the samples from animals from herds free of brucellosis reacted in the flow assays indicating a high specificity. However, as expected, some degree of reactivity was observed when testing selected serum samples that reacted non-specific in reference tests for brucellosis.

  15. Field Testing of a 1/100th Scale Starshade

    Science.gov (United States)

    Casement, L. S.; Glassman, T. M.; Lo, A.; Warwick, S.; Armagan, O.

    2013-01-01

    The external starshade is a prospective method for the direct detection and spectral characterization of terrestrial planets around other stars, a key goal identified in ASTRO2010. Validation of this approach has been challenging at ~1/1000th scale in the lab (Samuele et al., 2010). Recently we have successfully fabricated 60 cm 1/100th scale) starshades and have begun a series of ground test experiments with them. Our first experiment, limited by city lights and a short (300 m) baseline between the telescope and the starshade, showed excellent light suppression of >106. We enhanced our experimental setup to provide longer baselines and reduced aperture size to provide a closer match to the Fresnel number expected for the flight system. We took our test equipment into the field for a test in November 2012, the results of which are presented here.

  16. Testing strong-field CED and QED with intense laser fields

    Energy Technology Data Exchange (ETDEWEB)

    Piazza, Antonino di; Hatsagortsyan, Karen Z.; King, Ben; Keitel, Christoph H. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany)

    2010-07-01

    Strong laser fields can be employed to test classical and quantum electrodynamics (CED and QED, respectively) under extreme conditions. A fundamental problem in electrodynamics is the ''radiation reaction'' problem: classically, an accelerated electron emits radiation and this emission alters the motion of the electron itself. The Landau-Lifshitz equation consistently describes the electron's motion in an external field by including radiation reaction. We explore a new scenario in which this equation can be in principle tested experimentally for the first time and with presently available laser technology. We will also briefly address quantum vacuum polarization effects. We demonstrate the possibility of observing electron-positron pair production in laser and nuclear fields, by controlling the tunneling barrier through the assistance of an additional high-energy photon. Finally, by exploiting the quantum interaction among real photon in vacuum, we propose a double-slit-like experiment devoid of any material parts.

  17. Fast ion confinement and stability in a neutral beam injected reversed field pinch

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, J. K.; Almagri, A. F.; Den Hartog, D. J.; Eilerman, S.; Forest, C. B.; Koliner, J. J.; Mirnov, V. V.; Morton, L. A.; Nornberg, M. D.; Parke, E.; Reusch, J. A.; Sarff, J. S.; Waksman, J. [University of Wisconsin, Madison, Wisconsin 53706 (United States); Belykh, V.; Davydenko, V. I.; Ivanov, A. A.; Polosatkin, S. V.; Tsidulko, Y. A. [Budker Institute of Nuclear Physics, Novosibirsk (Russian Federation); Lin, L. [University of California, Los Angeles, California 90095 (United States); Liu, D. [University of California, Irvine, California 92697 (United States); and others

    2013-05-15

    The behavior of energetic ions is fundamentally important in the study of fusion plasmas. While well-studied in tokamak, spherical torus, and stellarator plasmas, relatively little is known in reversed field pinch plasmas about the dynamics of fast ions and the effects they cause as a large population. These studies are now underway in the Madison Symmetric Torus with an intense 25 keV, 1 MW hydrogen neutral beam injector (NBI). Measurements of the time-resolved fast ion distribution via a high energy neutral particle analyzer, as well as beam-target neutron flux (when NBI fuel is doped with 3–5% D{sub 2}) both demonstrate that at low concentration the fast ion population is consistent with classical slowing of the fast ions, negligible cross-field transport, and charge exchange as the dominant ion loss mechanism. A significant population of fast ions develops; simulations predict a super-Alfvénic ion density of up to 25% of the electron density with both a significant velocity space gradient and a sharp radial density gradient. There are several effects on the background plasma including enhanced toroidal rotation, electron heating, and an altered current density profile. The abundant fast particles affect the plasma stability. Fast ions at the island of the core-most resonant tearing mode have a stabilizing effect, and up to 60% reduction in the magnetic fluctuation amplitude is observed during NBI. The sharp reduction in amplitude, however, has little effect on the underlying magnetic island structure. Simultaneously, beam driven instabilities are observed as repetitive ∼50 μs bursts which coincide with fast particle redistribution; data indicate a saturated core fast ion density well below purely classical predictions.

  18. Field Test of Expedient Pavement Repairs (Test Items 16-35).

    Science.gov (United States)

    1980-11-01

    7 AD-AlG 903 A IR FORCE ENGINEERING AND SERVICES CENTER TYNDALL AF--ETC FG 13/2 FIELD TEST OF EXPEDIENT PAVEMENT REPAIRS ( TEST ITEMS 16-35).(U...PAVEMENT REPAIRS ~( TEST ITEMS 16-35) MICHAEL T. McNERNEY ENGINEERING RESEARCH DIVISION NOVEMBER 1980 ’ FINAL REPORT JULY 1978 - SEPTEMBER 1979 APPROVED FOR...EXPEDIENT PAVEMENT REPAIRS Final Reportg- July 1978- ( TEST ITEMS 16-35), Segtr W79 7. "AUTHOR(s) 8 CONTRACT OR GRANT NUMBER(s) Michael T./lcNernev, P

  19. Field assessments in conjunction with whole effluent toxicity testing

    Energy Technology Data Exchange (ETDEWEB)

    La Point, T.W.; Waller, W.T.

    2000-01-01

    Whole effluent toxicity (WET) tests are widely used to assess potential effects of wastewater discharges on aquatic life. This paper represents a summary of chapters in a 1996 Society of Environmental Toxicology and Chemistry-sponsored workshop and a literature review concerning linkages between WET testing and associated field biomonitoring. Most published studies thus far focus primarily on benthic macroinvertebrates and on effluent-dominated stream systems in which effluents demonstrate little or no significant acute toxicity. Fewer studies examine WET test predictability in other aquatic ecosystems (e.g., wetlands, estuaries, large rivers) or deal with instream biota such as fish and primary producers. Published results indicate that standards for the usual WET freshwater test species, Ceriodaphnia dubia and Pimephales promelas, may not always protect most of the species inhabiting a receiving stream. Although WET tests are useful in predicting aquatic individual responses, they are not meant to directly measure natural population or community responses. Further, they do not address bioconcentration or bioaccumulation of hydrophobic compounds; do not assess eutrophication effects in receiving systems; and lastly, do not reflect genotoxic effects or function to test for endocrine-disrupting chemicals. Consequently, a more direct evaluation of ecosystem health, using bioassessment techniques, may be needed to properly evaluate aquatic systems affected by wastewater discharges.

  20. The heparin-glutathione test: an alternative to the hypo-osmotic swelling test to select viable sperm for intracytoplasmic sperm injection.

    Science.gov (United States)

    Vendrell, F J; Rubio, C; Tarín, J J

    1998-12-01

    To evaluate the heparin-glutathione test (HEGLUT) for the selection of viable sperm for intracytoplasmic sperm injection (ICSI). A prospective study. Department of Pediatrics, Obstetrics and Gynecology, University of Valencia and Instituto Valenciano de Infertilidad. Semen samples from healthy donors and patients with infertility. Sperm samples were kept in culture for different periods in Ham's F-10 medium supplemented or not supplemented with heparin, reduced glutathione (GSH), or a heparin-GSH mixture. Control and heparin-GSH-treated spermatozoa were injected into hamster oocytes. The HEGLUT and ICSI were performed. Sperm nuclear decondensation, progressive and nonprogressive motility, and male pronucleus formation. The maximum proportion of sperm nuclear decondensation (28.7%+/-2.1% versus 2.6%+/-0.5% in the control group) was reached after 60 minutes of incubation in the presence of a heparin-GSH mixture. Differences in the percentages of progressive and nonprogressive motility among treatments and times of incubation, although statistically significant, were biologically negligible. No statistically significant differences were observed in the rate of sperm head decondensation (8.2% [4/49] versus 11.1% [6/54]) and male pronucleus formation (18.4% [9/49] versus 22.2% [12/541) after the injection of control and treated spermatozoa into hamster oocytes. The HEGLUT may offer an alternative to the hypo-osmotic swelling test for the selection of viable sperm for ICSI.

  1. High temperature superconducting axial field magnetic coupler: realization and test

    Science.gov (United States)

    Belguerras, L.; Mezani, S.; Lubin, T.; Lévêque, J.; Rezzoug, A.

    2015-09-01

    Contactless torque transmission through a large airgap is required in some industrial applications in which hermetic isolation is necessary. This torque transmission usually uses magnetic couplers, whose dimension strongly depends on the airgap flux density. The use of high temperature superconducting (HTS) coils to create a strong magnetic field may constitute a solution to reduce the size of the coupler. It is also possible to use this coupler to replace a torque tube in transmitting the torque produced by a HTS motor to its load. This paper presents the detailed construction and tests of an axial field HTS magnetic coupler. Pancake coils have been manufactured from BSCCO tape and used in one rotor of the coupler. The second rotor is mainly composed of NdFeB permanent magnets. Several tests have been carried out showing that the constructed coupler is working properly. A 3D finite element (FE) model of the studied coupler has been developed. Airgap magnetic field and torque measurements have been carried out and compared to the FE results. It has been shown that the measured and the computed quantities are in satisfactory agreement.

  2. Field Measurements and Pullout Tests of Reinforced Earth Retaining Wall

    Institute of Scientific and Technical Information of China (English)

    陈群; 何昌荣; 朱分清

    2004-01-01

    In this paper, field measurements and pullout tests of a new type of reinforced earth retaining wall, which is reinforced by trapezoid concrete blocks connected by steel bar, are described. Field measurements included settlements of the earth fill, tensile forces in the ties and earth pressures on the facing panels during the construction and at completion. Based on the measurements, the following statements can be made: ( 1 ) the tensile forces in the ties increased with the height of backfill above the tie and there is a tensile force crest in most ties; (2) at completion, the measured earth pressures along the wall face were between the values of the active earth pressures and the pressures at rest; (3) larger settlements occurred near the face of the wall where a zone of drainage sand and gravel was not compacted properly and smaller settlements occurred in the well-compacted backfill. The results of field pullout tests indicated that the magnitudes of pullout resistances as well as tensile forces induced in the ties were strongly influenced by the relative displacements between the ties and the backfill, and pullout resistances increased with the height of backfill above the ties and the length of ties.

  3. Injecting drugs of abuse and immunity: implications for HIV vaccine testing and efficacy.

    Science.gov (United States)

    Ugen, Kenneth E; Nyland, Susan B

    2006-11-01

    The recreational use of legal and illegal drugs has significant effects on immune responses and can potentially modulate susceptibility to infection by a number of pathogens. A number of agents including cannabinoids (marijuana), cocaine opiates, amphetamines, nicotine and alcohol were demonstrated to have potentially adverse effects on the susceptibility to infections, mediated most likely, by adverse effects on immunity. As such, these drugs of abuse could have significant and potentially adverse effects on the vaccination efficacy of a number of vaccines currently on the market and on potential experimental vaccines currently in the pipeline. This review will present an overview on how drugs of abuse potentially impacts immune responses and vaccination efficacy. The emphasis of this review will be the effects of opiate abuse, as exemplified by injecting/intravenous drug users (IDU), on HIV/AIDS and its potential impact on vaccine efficacy trials against this devastating infection/syndrome.

  4. Electric-field enhanced thermionic emission model for carrier injection mechanism of organic field-effect transistors: understanding of contact resistance

    Science.gov (United States)

    Li, Jun; Ou-Yang, Wei; Weis, Martin

    2017-01-01

    We developed an electric-field enhanced thermionic emission model combined with an equivalent circuit for a three-terminal organic transistor structure to interpret the gate-voltage dependent contact resistance. In the model the contact resistance is composed of two components: (i) the interfacial resistance not only influenced by interfacial energy barrier but also strongly dependent on active layer thickness, and (ii) the bulk resistance that is affected only by active layer itself. The model having physical meaning in the fitting parameters, different from the previous with simple power functions, can well fit the voltage dependence for a series of independent data. In addition, the bulk resistance component can be extracted and is estimated reasonable for the first time, which is demonstrated not to be neglected even for the devices with high effective mobility. The developed model will be helpful for understanding of contact resistance and charge carrier injection behavior in the organic thin film transistors.

  5. [Optimization of reaction conditions and methodological investigation on microtox-based fast testing system for traditional Chinese medicine injection].

    Science.gov (United States)

    Gao, Hong-Li; Li, Xiao-Rong; Yan, Liang-Chun; Zhao, Jun-Ning

    2016-05-01

    Vibrio fischeri CS234 was used to establish and optimize microtox assay system, laying a foundation for the application of this method in comprehensive acute toxicity test of traditional Chinese medicine (TCM) injections. Firstly, the Plackett-Burman method was carried out to optimize the factors which would affect Vibrio fischeri CS234 luminescence. Secondly, ZnSO4•7H2O was chosen as reference substance to establish its reaction system with quality control samples. The optimal luminescence conditions were achieved as follows: ①At a temperature of (15±1) ℃, Vibrio fischeri CS234 lyophilized powders were balanced for 15 min, then, 1 mL resuscitation fluid was added and blended for 10 min. 100 μL bacteria suspension was taken to measure the initial luminescence intensity, and then 1 mL resuscitation fluid or test sample was immediately added; after reaction for 10 min, corresponding luminescence intensity was measured again. Resuscitation diluent, osmotic pressure regulator and ZnSO4•7H2O stock solution showed no interference to the determination of Vibrio fischeri CS234 luminescence intensity, so this method was of good specificity. The within-and between-batch precisions of quality controls and the lower limit of quantification (LLOQ) samples were testing needs of the vast majority of traditional Chinese medicine injections. The Vibrio fischeri strain CS234 assay system was specific, stable, sensitive, accurate and adaptable after optimization, so it was suitable for the comprehensive acute toxicity assessment of TCM injections. Copyright© by the Chinese Pharmaceutical Association.

  6. Relation of field independence and test-item format to student performance on written piagetian tests

    Science.gov (United States)

    Ló; Pez-Rupérez, F.; Palacios, C.; Sanchez, J.

    In this study we have investigated the relationship between the field-dependence-independence (FDI) dimension as measured by the Group Embedded Figures Test (GEFT) and subject performance on the Longeot test, a pencil-and-paper Piagetian test, through the open or closed format of its items. The sample consisted of 141 high school students. Correlation and variance analysis show that the FDI dimension and GEFT correlate significantly on only those items on the Longeot test that require formal reasoning. The effect of open- or closed-item format is found exclusively for formal items; only the open format discriminates significantly (at the 0.01 level) between the field-dependent and -independent subjects performing on this type of item. Some implications of these results for science education are discussed.

  7. Field tests of 2- and 40-tube condensers at the East Mesa Geothermal Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, R.W.; Domingo, N.

    1982-05-01

    Two water-cooled isobutane condensers, one with 2 tubes and one with 40 tubes, were subjected to field tests at the East Mesa Geothermal Test Site to assess relative heat transfer performance in both surface evaporator and direct-contact evaporator modes. The five groups of tests established that field performance was below earlier laboratory-determined levels and that direct-contact evaporator mode performance was poorer than that for the surface evaporator mode. In all test situations, fluted condenser tubes performed better than smooth condenser tubes. Cooling water quality had no significant effect on performance, but brine preflash in the direct-contact mode did promote some relative performance improvement. Important implications of these results for binary geothermal power plants are that (1) working-fluid-side impurities can significantly degrade heat transfer performance of the power plant condensers and (2) provisions for minimizing such impurities may be required.

  8. TEST OF AN ANIMAL DRAWN FIELD IMPLEMENT CART

    Directory of Open Access Journals (Sweden)

    Paolo Spugnoli

    2008-06-01

    Full Text Available The field performance of a horse-drawn hitch cart equipped with a PTO system powered by the two cart ground wheels have been investigated. For this purpose field tests on clay and turf soil, with varying ballast and PTO torque, have been carried out pulling the cart by a tractor. Preliminary tests were aimed at assessing the traction capability of horse breed. These tests showed that the mean draught force given by two of these horses was 173daN, average working speed was about 1m*s-1, resulting a mean draught power developed by each horse of about 0.86kW. The PTO cart system performance has shown that the torque has not exceeded 2.4daN*m, maximum draught or PTO power was 1.15kW, rotation speed just higher than 400min-1, with mean efficiency of about 50%. These values are consistent with horse performance and small haymaking, fertilizing, seeding and chemical application machine requirements.

  9. Detailed field test of yaw-based wake steering

    Science.gov (United States)

    Fleming, P.; Churchfield, M.; Scholbrock, A.; Clifton, A.; Schreck, S.; Johnson, K.; Wright, A.; Gebraad, P.; Annoni, J.; Naughton, B.; Berg, J.; Herges, T.; White, J.; Mikkelsen, T.; Sjöholm, M.; Angelou, N.

    2016-09-01

    This paper describes a detailed field-test campaign to investigate yaw-based wake steering. In yaw-based wake steering, an upstream turbine intentionally misaligns its yaw with respect to the inflow to deflect its wake away from a downstream turbine, with the goal of increasing total power production. In the first phase, a nacelle-mounted scanning lidar was used to verify wake deflection of a misaligned turbine and calibrate wake deflection models. In the second phase, these models were used within a yaw controller to achieve a desired wake deflection. This paper details the experimental design and setup. All data collected as part of this field experiment will be archived and made available to the public via the U.S. Department of Energy's Atmosphere to Electrons Data Archive and Portal.

  10. Fault detection by surface seismic scanning tunneling macroscope: Field test

    KAUST Repository

    Hanafy, Sherif M.

    2014-08-05

    The seismic scanning tunneling macroscope (SSTM) is proposed for detecting the presence of near-surface impedance anomalies and faults. Results with synthetic data are consistent with theory in that scatterers closer to the surface provide brighter SSTM profiles than those that are deeper. The SSTM profiles show superresolution detection if the scatterers are in the near-field region of the recording line. The field data tests near Gulf of Aqaba, Haql, KSA clearly show the presence of the observable fault scarp, and identify the subsurface presence of the hidden faults indicated in the tomograms. Superresolution detection of the fault is achieved, even when the 35 Hz data are lowpass filtered to the 5-10 Hz band.

  11. Test plan for FY-94 digface characterization field experiments

    Energy Technology Data Exchange (ETDEWEB)

    Josten, N.E.; Roybal, L.G.

    1994-08-01

    The digface characterization concept has been under development at the Idaho National Engineering Laboratory (INEL) since fiscal year (FY) 1992 through the support of the Buried Waste Integrated Demonstration Program. A digface characterization system conducts continuous subsurface characterization simultaneously with retrieval of hazardous and radioactive waste from buried waste sites. The system deploys multiple sensors at the retrieval operation digface and collects data that provide a basis for detecting, locating, and classifying buried materials and hazardous conditions before they are disturbed by the retrieval equipment. This test plan describes ongoing efforts to test the digface characterization concept at the INEL`s Cold Test Pit using a simplified prototype deployment apparatus and off-the-shelf sensors. FY-94 field experiments will explore problems in object detection and classification. Detection and classification of objects are fundamental to three of the four primary functions of digface characterization during overburden removal. This test plan establishes procedures for collecting and validating the digface characterization data sets. Analysis of these data will focus on testing and further developing analysis methods for object detection and classification during overburden removal.

  12. FIELD IMPLEMENTATION PLAN FOR A WILLISTON BASIN BRINE EXTRACTION AND STORAGE TEST

    Energy Technology Data Exchange (ETDEWEB)

    Hamling, John; Klapperich, Ryan; Stepan, Daniel; Sorensen, James; Pekot, Lawrence; Peck, Wesley; Jacobson, Lonny; Bosshart, Nicholas; Hurley, John; Wilson, William; Kurz, Marc; Burnison, Shaughn; Salako, Olarinre; Musich, Mark; Botnen, Barry; Kalenze, Nicholas; Ayash, Scott; Ge, Jun; Jiang, Tao; Dalkhaa, Chantsalmaa; Oster, Benjamin; Peterson, Kyle; Feole, Ian; Gorecki, Charles; Steadman, Edward

    2016-03-31

    The Energy & Environmental Research Center (EERC) successfully completed all technical work of Phase I, including development of a field implementation plan (FIP) for a brine extraction and storage test (BEST) in the North Dakota portion of the Williston Basin. This implementation plan was commissioned by the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) as a proxy for managing formation pressure plumes and measuring/monitoring the movement of differential pressure and CO2 plumes in the subsurface for future saline CO2 storage projects. BEST comprises the demonstration and validation of active reservoir management (ARM) strategies and extracted brine treatment technologies. Two prospective commercial brine injection sites were evaluated for BEST to satisfy DOE’s goals. Ultimately, an active saltwater disposal (SWD) site, Johnsons Corner, was selected because it possesses an ideal combination of key factors making it uniquely suited to host BEST. This site is located in western North Dakota and operated by Nuverra Environmental Solutions (Nuverra), a national leader in brine handling, treatment, and injection. An integrated management approach was used to incorporate local and regional geologic characterization activities with geologic and simulation models, inform a monitoring, verification, and accounting (MVA) plan, and to conduct a risk assessment. This approach was used to design a FIP for an ARM schema and an extracted brine treatment technology test bed facility. The FIP leverages an existing pressure plume generated by two commercial SWD wells. These wells, in conjunction with a new brine extraction well, will be used to conduct the ARM schema. Results of these tests will be quantified based on their impact on the performance of the existing SWD wells and the surrounding reservoir system. Extracted brine will be injected into an underlying deep saline formation through a new injection well. The locations of proposed

  13. Electron self-injection for the acceleration in laser-pulse-wakes in the presence of a `strong' external magnetic field

    CERN Document Server

    Zhidkov, A; Masuda, S; Oishi, Y; Fujii, T; Kodama, R

    2012-01-01

    An external static magnetic field with its strength B~10T may result in the laser wake wave-breaking upon changing the electron motion in the vicinity of maximal density ramp of a wave period. This, as shown by numerical simulations, can change the resonance character of the electron self-injection in the laser wake-field; a total charge loaded in the acceleration phase of laser pulse wake can be controlled by a proper choice of the magnetic field strength.

  14. Validity of Selected Lab and Field Tests of Physical Working Capacity.

    Science.gov (United States)

    Burke, Edmund J.

    The validity of selected lab and field tests of physical working capacity was investigated. Forty-four male college students were administered a series of lab and field tests of physical working capacity. Lab tests include a test of maximum oxygen uptake, the PWC 170 test, the Harvard Step Test, the Progressive Pulse Ratio Test, Margaria Test of…

  15. Field Test Results from a 10 kW Wind Turbine with Active Flow Control

    Science.gov (United States)

    Rice, Thomas; Bychkova, Veronika; Taylor, Keith; Clingman, Dan; Amitay, Michael

    2015-11-01

    Active flow control devices including synthetic jets and dynamic vortex generators were tested on a 10 kW wind turbine at RPI. Previous work has shown that load oscillations caused by dynamic stall could be modified through the use of active flow control by injecting momentum into the flow field near the leading edge of a dynamically pitching model. In this study, this work has been extended to its logical conclusion, field-testing active flow control on a real wind turbine. The blades in the current study have a 0.28m chord and 3.05m span, no twist or taper, and were retrofitted with six synthetic jets on one blade and ten dynamic vortex generators on a second blade. The third blade of this turbine was not modified, in order to serve as a control. Strain gauges were installed on each blade to measure blades' deflection. A simple closed loop control was demonstrated and preliminary results indicate reduced vibrational amplitude. Future testing will be conducted on a larger scale, 600kW machine at NREL, incorporating information collected during this study.

  16. Protection of telephone cables serving substations : proposal for new protection criteria based on field test results

    Energy Technology Data Exchange (ETDEWEB)

    De Seve, J. [Hydro-Quebec, Montreal, PQ (Canada)

    2009-07-01

    This presentation discussed a field test conducted to develop new protection criteria for telephone cables serving substations. Most distribution substations in rural areas are not linked to Hydro-Quebec's telecommunication network. However, the cost advantage of using wireless or fiber optic links cannot be justified despite the fact that more than 200 sites are in need of additional electrical protection. The field tests were conducted at 2 rural 120/25 kV substations in order to determine reduction factors and grounding for cable sheaths. Faults on the distribution line were examined as well as high voltage (HV) faults at the substation. Approximately 440 current injections were applied over a testing period of 24 days. Voltage measurements were conducted for an area up to 100 km{sup 2} around the substations. The study showed that transferred voltage along metallic links and mutual resistance between the ground electrodes influenced soil voltage profiles. Transfer voltages travelled more than 5 km in rural areas. Grounding reference for customers reached more than 70 per cent of the GPR value. The study showed that a reduction factor of at least 40 per cent can be used for high voltage faults in MGN distribution substations. Power line sheaths can be grounded if sheath temperature can be limited to 110 degrees C. An updated Hydro-Quebec cable protection policy was included. tabs., figs.

  17. Preliminary operational results of the industrial process heat field tests

    Energy Technology Data Exchange (ETDEWEB)

    Kutscher, C.; Davenport, R.

    1980-04-01

    There are currently six DOE-funded solar industrial process heat (IPH) field tests which have been operational for one year or longer. These are all low temperature first generation projects which supply heat at temperatures below 100/sup 0/C - three hot water and three hot air. During the 1979 calendar year, personnel from the Solar Energy Research Institute (SERI) visited all of these sites; the performance and cost results obtained for each project and the operational problems encountered at each site are discussed.

  18. Pulsed mixed n, {gamma} radiation fields for electronic testing

    Energy Technology Data Exchange (ETDEWEB)

    Nurdin, G.; Becret, C.; Jaureguy, J.C. [Etablissement Technique Central de l`Armement (ETCA), 94 - Arcueil (France); Vie, M.; Baboulet, J.P.; Lapeyre, P.; Ramisse, D. [D.G.A., 46 - Gramat (France)

    1994-12-31

    For combined n, {gamma} TREE testing we have modified the CALIBAN Fast Burst Reactor Field with CdO/Epoxy converters to cover the range [10{sup 11} -10{sup 12}] n.cm{sup -2} (1 MeV Si), [10{sup 7} - 10{sup 8}] cGy(Si).s{sup -1}. Activation and fission {sigma} {phi}vector, 1 MeV(Si) fluences, neutron spectra, total exposures and dose rates were predicted with good agreement by n, {gamma} photon transport codes. (author). 12 refs., 2 figs., 1 tab.

  19. Detailed field test of yaw-based wake steering

    DEFF Research Database (Denmark)

    Fleming, P.; Churchfield, M.; Scholbrock, A.

    2016-01-01

    This paper describes a detailed field-test campaign to investigate yaw-based wake steering. In yaw-based wake steering, an upstream turbine intentionally misaligns its yaw with respect to the inflow to deflect its wake away from a downstream turbine, with the goal of increasing total power...... production. In the first phase, a nacelle-mounted scanning lidar was used to verify wake deflection of a misaligned turbine and calibrate wake deflection models. In the second phase, these models were used within a yaw controller to achieve a desired wake deflection. This paper details the experimental...

  20. Field Test: Results from the One Year Mission

    Science.gov (United States)

    Reschke, M. F.; Kozlovskaya, I. B.; Kofman, I. S.; Tomilovskaya, E. S.; Cerisano, J. M.; Rosenberg, M. J. F.; Bloomberg, J. J.; Stenger, M. B.; Lee, S. M. C.; Laurie, S. S.; Rukavishnikov, I. V.; Fomina, E. V.; Wood, S. J.; Mulavara, A. P.; Feiveson, A. H.; Fisher, E. A.; Phillips, T.; Ribeiro, C.; Taylor, L. C.; Miller, C. A.; Gadd, N. E.; Peters, B. T.; Kitov, V. V.; Lysova, N. Yu; Holden, K. L.; De Dios, Y.

    2017-01-01

    The One Year Mission was designed to aid in determining the effect that extending the duration on orbit aboard the International Space Station (ISS) would have on a number of biological and physiological systems. Two crewmembers were selected to participate in this endeavor, one U.S. On-Orbit Segment (USOS) astronaut and one Russian cosmonaut. The Neuroscience and Cardiovascular and Vision Laboratories at the Johnson Space Center and the Sensory-Motor and Countermeasures Division within the Institute for Biomedical Problems were selected to investigate vestibular, sensorimotor and cardiovascular function with the two long-duration crewmembers using the established methodology developed for the Field Test (FT).

  1. Development of a magnetized coaxial plasma gun for compact toroid injection into the C-2 field-reversed configuration device.

    Science.gov (United States)

    Matsumoto, T; Sekiguchi, J; Asai, T; Gota, H; Garate, E; Allfrey, I; Valentine, T; Morehouse, M; Roche, T; Kinley, J; Aefsky, S; Cordero, M; Waggoner, W; Binderbauer, M; Tajima, T

    2016-05-01

    A compact toroid (CT) injector was developed for the C-2 device, primarily for refueling of field-reversed configurations. The CTs are formed by a magnetized coaxial plasma gun (MCPG), which consists of coaxial cylindrical electrodes and a bias coil for creating a magnetic field. First, a plasma ring is generated by a discharge between the electrodes and is accelerated by Lorenz self-force. Then, the plasma ring is captured by an interlinkage flux (poloidal flux). Finally, the fully formed CT is ejected from the MCPG. The MCPG described herein has two gas injection ports that are arranged tangentially on the outer electrode. A tungsten-coated inner electrode has a head which can be replaced with a longer one to extend the length of the acceleration region for the CT. The developed MCPG has achieved supersonic CT velocities of ∼100 km/s. Plasma parameters for electron density, electron temperature, and the number of particles are ∼5 × 10(21) m(-3), ∼40 eV, and 0.5-1.0 × 10(19), respectively.

  2. Hypersensitivity test to electric magnetic fields; Test de hipersensibilidad a exposiciones residenciales a campos magneticos

    Energy Technology Data Exchange (ETDEWEB)

    Ubeda Maeso, A.; Martinez Pascual, M. A.

    2004-07-01

    The so-called electromagnetic hypersensitivity (RH) syndrome includes a number of unspecific, medically unexplained symptoms attributed to exposure to electric and magnetic fields. As a whole, laboratory tests have provided inconclusive results, in part due to the fact that many individuals show nuclear, inconsistent responses to repeated experimental field-exposures. It has been proposed that such inconsistencies could be due in part to distress caused by the lab test itself. We have developed a test to be conducted at the patient's residence, allowing for long-term follow up of exposure-response assessment and avoiding the laboratory environment and the presence of the researcher as potential stressors and confounding factors. In a pilot test, EMDEX-II magnetometers were used to continuously recording power-frequency magnetic fields in the residence of a patient with perceived EH. The patient's symptoms included distress, headache and dizziness, among other ailments. Magnetographic data of a total of 123 recording days were plotted against the corresponding data on occurrence of the symptoms episodes. As a whole, the results did not show positive linear correlation between the daily occurrence of the episode and the exposures levels recorded during the day or during the day before. These preliminary results are little supportive of the hypothesis that the patient's ailments are caused or worsened by a putative hypersensitivity to residential exposure to power-frequency magnetic fields in the 0.02-4.00 {mu}T range. (Author) 29 refs.

  3. Field tests of a tissue-equivalent beta survey meter

    Energy Technology Data Exchange (ETDEWEB)

    Martz, D.E.; Johnson, L.O.; Rich, B.L.; Daniel, S.H.

    1986-01-01

    A tissue-equivalent survey meter for monitoring the (dD/dt)(0.07) and (dD/dt)(10) dose rates produced by betas and photons has been designed and tested. The very thin tissue-equivalent plastic scintillator closely simulates the critical skin tissue layer between 4 mg.cm/sup -2/ and 9 mg.cm/sup -2/. The meter is calibrated to read the (dD/dt)(0.07) dose rate directly, and the (dD/dt)(10) dose rate behind a filter. Laboratory measurements of calibrated sources and field tests have demonstrated tissue-equivalent response of the survey meter to betas between 70 keV and 2500 keV and to photons with energies greater than about 30 keV.

  4. Pre-Test CFD for the Design and Execution of the Enhanced Injection and Mixing Project at NASA Langley Research Center

    Science.gov (United States)

    Drozda, Tomasz G.; Axdahl, Erik L.; Cabell, Karen F.

    2014-01-01

    With the increasing costs of physics experiments and simultaneous increase in availability and maturity of computational tools it is not surprising that computational fluid dynamics (CFD) is playing an increasingly important role, not only in post-test investigations, but also in the early stages of experimental planning. This paper describes a CFD-based effort executed in close collaboration between computational fluid dynamicists and experimentalists to develop a virtual experiment during the early planning stages of the Enhanced Injection and Mixing project at NASA Langley Research Center. This projects aims to investigate supersonic combustion ramjet (scramjet) fuel injection and mixing physics, improve the understanding of underlying physical processes, and develop enhancement strategies and functional relationships relevant to flight Mach numbers greater than 8. The purpose of the virtual experiment was to provide flow field data to aid in the design of the experimental apparatus and the in-stream rake probes, to verify the nonintrusive measurements based on NO-PLIF, and to perform pre-test analysis of quantities obtainable from the experiment and CFD. The approach also allowed for the joint team to develop common data processing and analysis tools, and to test research ideas. The virtual experiment consisted of a series of Reynolds-averaged simulations (RAS). These simulations included the facility nozzle, the experimental apparatus with a baseline strut injector, and the test cabin. Pure helium and helium-air mixtures were used to determine the efficacy of different inert gases to model hydrogen injection. The results of the simulations were analyzed by computing mixing efficiency, total pressure recovery, and stream thrust potential. As the experimental effort progresses, the simulation results will be compared with the experimental data to calibrate the modeling constants present in the CFD and validate simulation fidelity. CFD will also be used to

  5. Corrective Action Decision Document for Corrective Action Unit 322: Areas 1 and 3 Release Sites and Injection Wells Nevada Test Site, Nevada, Rev. No. 0

    Energy Technology Data Exchange (ETDEWEB)

    Robert Boehlecke

    2004-12-01

    This Corrective Action Decision Document has been prepared for Corrective Action Unit (CAU) 322, Areas 1 and 3 Release Sites and Injection Wells, Nevada Test Site, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (1996). Corrective Action Unit 322 is comprised of the following corrective action sites (CASs): (1) 01-25-01 - AST Release Site; (2) 03-25-03 - Mud Plant and AST Diesel Release; and (3) 03-20-05 - Injection Wells and BOP Shop. The purpose of this Corrective Action Decision Document is to identify and provide the rationale for the recommendation of a corrective action alternative for each CAS within CAU 322. Corrective action investigation activities were performed from April 2004 through September 2004, as set forth in the Corrective Action Investigation Plan. The purposes of the activities as defined during the data quality objectives process were: (1) Determine if contaminants of concern (COCs) are present; (2) If COCs are present, determine their nature and extent; and (3) Provide sufficient information and data to recommend appropriate corrective actions for the CASs. Analytes detected during the corrective action investigation were evaluated against appropriate preliminary action levels to identify contaminants of concern for each corrective action site. Radiological field measurements were compared to unrestricted release criteria. Assessment of the data generated from investigation activities revealed the following: (1) CAS 01-25-01 contains an AST berm contaminated with total petroleum hydrocarbons (TPH) diesel-range organics (DRO). (2) CAS 03-25-03 includes two distinct areas: Area A where no contamination remains from a potential spill associated with an AST, and Area B where TPH-DRO contamination associated with various activities at the mud plant was identified. The Area B contamination was found at various locations and depths. (3) CAS 03-25-03 Area B contains TPH-DRO contamination at various

  6. First field test of FiDeL The magnetic field description for the LHC

    CERN Document Server

    Bottura, L; Catalan-Lasheras, N; Deniau, L; Di Castro, M; Fartoukh, S; Giovannozzi, M; Hagen, P; Koutchouk, Jean-Pierre; Lamont, M; Miles, J; Remondino, V; Sammut, N; Sanfilippo, S; Schmidt, F; Sernelius, D; Steinhagen, R; Strzelczyk, M; Tomás, R; Todesco, E; Venturini-Delsolaro, W; Walckiers, L; Wenninger, J; Wolf, R; Xydi, P

    2010-01-01

    The start-up of the LHC has provided the first field test for the concept, functionality and accuracy of FiDeL, the Field Description for the LHC. FiDeL provides a parametric model of the transfer function of the main field integrals generated by the series of magnets in the LHC powering circuits, comprising superconducting and normal-conducting main optical elements and high-order harmonic correctors. The same framework is used to predict harmonic errors of both static and dynamic nature, and forecast appropriate corrections. In this paper we make use of beam-based measurements taken on the first LHC beams to assess the first-shot accuracy in the prediction of the current setting for the main arc magnets.

  7. Modular Integrated Monitoring System (MIMS) field test installations

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, R.L.; Waymire, D.R. [Sandia National Labs., Albuquerque, NM (United States); Fuess, D.A. [Lawrence Livermore National Lab., CA (United States)] [and others

    1995-07-01

    The MIMS program is funded by the Department of Energy under the Office of Nonproliferation and National Security. The program objective is to develop cost effective, modular, multi-sensor monitoring systems. Both in-plant and ground based sensors are envisioned. It is also desirable to develop sensors/systems that can be fielded/deployed in a rapid fashion. A MIMS architecture was selected to allow modular integration of sensors and systems and is based on LonWorks technology, commercially developed by Echelon Corporation. The first MIMS fieldable hardware was demonstrated at Lawrence Livermore National Laboratory. The field test, known within the DOE as the Item Tracking and Transparency (IT&I) demonstration, involved the collaboration and cooperation of five DOE laboratories (Sandia (SNL), Lawrence Livermore (LLNL), Pacific Northwest (PNL), Los Alamos (LANL), and Oak Ridge (ORNL)). The IT&T demonstration involved the monitoring of special nuclear material as it was transported around the facility utilizing sensors from the participating labs. The scenario was programmed to ignore normal activity in the facility until entry into the room where the material was stored. A second demonstration, which involved three separate scenarios, was conducted at Idaho National Engineering Laboratory (INEL). The participants included representatives from SNL, LLNL, PNL, and INEL. DOE has selected INEL as the long term testbed for MIMS developed sensors, systems, and scenarios. This paper will describe the installation, intended purpose, and results of the field demonstrations at LLNL and INEL under the MIMS program.

  8. Appraisal of oil-water separation in field by injection of demulsifier through gas-lift line; Avaliacao da separacao agua-oleo em campo injetando desemulsificante atraves da linha de gas-lift

    Energy Technology Data Exchange (ETDEWEB)

    Ramalho, Joao Batista Vianey da Silva [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas. Setor de Pesquisa, Desenvolvimento e Engenharia]. E-mail: jramalho@cenpes.petrobras.com.br

    2001-12-01

    During the petroleum dehydrating process, the use of demulsifiers is fundamental in the coalescing of emulsions formed in field from the produced petroleum and water. Injection of demulsifiers should be performed the most upstream possible of the processing plant, not only to allow better product performance but to avoid the formation of smaller water drops, due to shearing during flowing of production. Herein presented are the test results of the d emulsifier's performances in field, injected through the gas-lift line of petroleum producing wells. The results showed water removal in the three-phase separator, even when operating in low processing temperature and low liquid residence time inside vessel. (author)

  9. Permeation Dispersal of Treatment Agents for In Situ Remediation in Low Permeability Media: 1. Field Studies in Unconfined Test Cells

    Energy Technology Data Exchange (ETDEWEB)

    Siegrist, R.L.; Smuin, D.R.; Korte, N.E.; Greene, D.W.; Pickering, D.A.; Lowe, K.S.; Strong-Gunderson, J.

    2000-08-01

    Chlorocarbons like trichloroethylene (TCE) are common contaminants of concern at US Department of Energy (DOE) facilities and industrial sites across the US and abroad. These contaminants of concern are present in source areas and in soil and ground water plumes as dissolved or sorbed phase constituents as well as dense nonaqueous-phase liquids (DNAPLs). These DNAPL compounds can be released to the environment through a variety of means including leaks in storage tanks and transfer lines, spills during transportation, and land treatment of wastes. When DNAPL compounds are present in low permeability media (LPM) like silt and clay layers or deposits, there are major challenges with assessment of their behavior and implementation of effective in situ remediation technologies. This report describes a field demonstration that was conducted at the Portsmouth Gaseous Diffusion Plant (PORTS) Clean Test Site (CTS) to evaluate the feasibility of permeation and dispersal of reagents into LPM. Various reagents and tracers were injected at seven test cells primarily to evaluate the feasibility of delivery, but also to evaluate the effects of the injected reagents on LPM. The various reagents and tracers were injected at the PORTS CTS using a multi-port injection system (MPIS) developed and provided by Hayward Baker Environmental, Inc.

  10. Field test of hydrogen in the natural gas grid

    Energy Technology Data Exchange (ETDEWEB)

    Iskov, H.

    2010-08-15

    In order to prepare for a future use of hydrogen as a fuel gas it became evident that very little information existed regarding the compatibility between long-term exposure and transportation of hydrogen in natural gas pipelines. A program was therefore set to study the transportation in a small-scale pilot grid at the research centre in Hoersholm, Denmark. The test program included steel pipes from the Danish gas transmission grid and polymer pipes from the Danish and Swedish gas distribution grid. The test of polymer pipes was devised so that samples of all test pipes were cut out of the grid each year and analysis performed on these pipe samples; in this way any form of influence on the integrity of the polyethylene pipe would be detected. The analytical program for polymer was devised in order to detect any influence on the additivation of the polyethylene as this has an influence on oxidative resistance, as well as checking already encountered possible degradation caused by extrusion of the material. Further tools as rheology and melt flow rate were used for detecting any structural changes on the material. On the mechanical property side the tensile strength and modulus were followed as well as the most important property for the pipe line, namely slow crack growth. The results of the polymer pipe tests show no degradations of any kind related to the continuous hydrogen exposure for more than 4 years. This is a strong indication of the compatibility to hydrogen of the tested polymer materials PE 80 and PE 100. The object of the steel pipe test was to see the effect on fatigue life of existing natural gas transmission lines with hydrogen replacing the natural gas. Full-scale dynamic tests were performed using randomly selected cut-out API 5L X70 pipe sections with a diameter of 20 inches and a wall thickness of 7 millimetres from the Danish natural gas transmission system. The pipe sections contained field girth weld made during the installation of the pipe

  11. Field Testing of Nano-PCM Enhanced Building Envelope Components

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, Kaushik [ORNL; Childs, Phillip W [ORNL; Atchley, Jerald Allen [ORNL

    2013-08-01

    The U.S. Department of Energy s (DOE) Building Technologies Program s goal of developing high-performance, energy efficient buildings will require more cost-effective, durable, energy efficient building envelopes. Forty-eight percent of the residential end-use energy consumption is spent on space heating and air conditioning. Reducing envelope-generated heating and cooling loads through application of phase change material (PCM)-enhanced envelope components can facilitate maximizing the energy efficiency of buildings. Field-testing of prototype envelope components is an important step in estimating their energy benefits. An innovative phase change material (nano-PCM) was developed with PCM encapsulated with expanded graphite (interconnected) nanosheets, which is highly conducive for enhanced thermal storage and energy distribution, and is shape-stable for convenient incorporation into lightweight building components. During 2012, two test walls with cellulose cavity insulation and prototype PCM-enhanced interior wallboards were installed in a natural exposure test (NET) facility at Charleston, SC. The first test wall was divided into four sections, which were separated by wood studs and thin layers of foam insulation. Two sections contained nano-PCM-enhanced wallboards: one was a three-layer structure, in which nano-PCM was sandwiched between two gypsum boards, and the other one had PCM dispersed homogeneously throughout graphite nanosheets-enhanced gypsum board. The second test wall also contained two sections with interior PCM wallboards; one contained nano-PCM dispersed homogeneously in gypsum and the other was gypsum board containing a commercial microencapsulated PCM (MEPCM) for comparison. Each test wall contained a section covered with gypsum board on the interior side, which served as control or a baseline for evaluation of the PCM wallboards. The walls were instrumented with arrays of thermocouples and heat flux transducers. Further, numerical modeling of

  12. Biodegradation of wastewater nitrogen compounds in fractures: Laboratory tests and field observations

    Science.gov (United States)

    Masciopinto, Constantino

    2007-07-01

    Throughout several coastal regions in the Mediterranean where rainfalls rarely exceed 650 mm per year municipal treated wastewater can be conveniently reused for soil irrigation. Where the coastal aquifer supplies large populations with freshwater in such area, an assessment of ground water quality around spreading sites is needed. In this study, the efficacy of natural filtration on nitrogen degradation in wastewater spreads on the soil covering the Salento (Southern Italy) fractured limestone was quantified by using laboratory tests and field measurements. In the laboratory, effluent from municipal wastewater treatment plants was filtered through a package of fractures made by several slabs of limestone. An analysis of wastewater constituent concentrations over time allowed the decay rates and constants for nitrogen transformation during natural filtration to be estimated in both aerated and non-aerated (i.e., saturated) soil fractures. A simulation code, based on biodegradation decay constants defined in the laboratory experiments, was then used to quantify the total inorganic nitrogen removal from wastewater injected in an aquifer in the Salento region (Nardò). Here the water sampled in two monitoring wells at 320 m and 500 m from the wastewater injection site and downgradient with respect to groundwater flow was used to verify the laboratory nitrification and denitrification rates.

  13. Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Pilot-Scale Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Gary M. Blythe

    2006-03-01

    This Topical Report summarizes progress on Cooperative Agreement DE-FC26-04NT42309, ''Field Testing of a Wet FGD Additive.'' The objective of the project is to demonstrate the use of a flue gas desulfurization (FGD) additive, Degussa Corporation's TMT-15, to prevent the reemissions of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project intends to demonstrate that the additive can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine TMT salt that can be separated from the FGD liquor and bulk solid byproducts for separate disposal. The project will conduct pilot and full-scale tests of the TMT-15 additive in wet FGD absorbers. The tests are intended to determine required additive dosage requirements to prevent Hg{sup 0} reemissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Power River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, TXU Generation Company LP, Southern Company, and Degussa Corporation. TXU Generation has provided the Texas lignite/PRB co-fired test site for pilot FGD tests, Monticello Steam Electric Station Unit 3. Southern Company is providing the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, as well as the pilot and full-scale jet bubbling reactor (JBR) FGD systems to be tested. A third utility, to be named later, will provide the high-sulfur Eastern bituminous coal full-scale FGD test site. Degussa Corporation is providing the TMT-15 additive and technical support to the test program. The project is being conducted in six tasks. Of the six project tasks, Task 1 involves project planning and Task 6 involves management and reporting. The other four tasks involve field testing on FGD systems, either at pilot or full scale. The four tasks include: Task 2

  14. Sperm tail flexibility test: a simple test for selecting viable spermatozoa for intracytoplasmic sperm injection from semen samples without motile spermatozoa

    Directory of Open Access Journals (Sweden)

    Soares Jonathas Borges

    2003-01-01

    Full Text Available PURPOSE: The objective was to describe the results of the injection of immotile spermatozoa with flexible tails when only immotile spermatozoa are present in the semen sample. METHODS: A retrospective study was conducted to analyze the procedure results for 10 couples who participated in our intracytoplasmic sperm injection program. The sperm tail was considered flexible when it moved up and down independently of the head movement, and it was considered inflexible when the movement occurred together (tail plus head. The fertilization and pregnancy rate were analyzed. RESULTS: The normal fertilization rate (presence of 2 pronuclei was 30.3% (40/132, and the abnormal fertilization rate (presence of less than or more than 2 pronuclei was 6.81% (9/132. A total of 52 embryos were obtained with 9 transfer procedures performed (pregnancy rate: 11.12%. CONCLUSIONS: The sperm tail flexibility test (STFT is an easy and cost-effective way for selecting viable immotile spermatozoa and can be used as an alternative method for determining the viability of spermatozoa. This test seems to be a simple and risk-free method when compared to the swelling test.

  15. 76 FR 3075 - Availability of an Environmental Assessment for Field Testing Feline Leukemia Vaccine, Live...

    Science.gov (United States)

    2011-01-19

    ... Feline Leukemia Vaccine, Live Canarypox Vector AGENCY: Animal and Plant Health Inspection Service, USDA... testing, and then to field test, an unlicensed Feline Leukemia Vaccine, Live Canarypox Vector. The.... Product: Feline Leukemia Vaccine, Live Canarypox Vector. Field Test Locations: Alabama,...

  16. 77 FR 22283 - Availability of an Environmental Assessment for Field Testing Feline Interleukin-2...

    Science.gov (United States)

    2012-04-13

    ... Feline Interleukin-2 Immunomodulator, Live Canarypox Vector AGENCY: Animal and Plant Health Inspection... of field testing, and then to field test, an unlicensed Feline Interleukin-2 ] Immunomodulator, Live... testing of the following unlicensed veterinary biological product: Requester: Merial, Inc. Product:...

  17. Cooperative field test program for wind systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bollmeier, W.S. II; Dodge, D.M.

    1992-03-01

    The objectives of the Federal Wind Energy Program, managed by the US Department of Energy (DOE), are (1) to assist industry and utilities in achieving a multi-regional US market penetration of wind systems, and (2) to establish the United States as the world leader in the development of advanced wind turbine technology. In 1984, the program conducted a series of planning workshops with representatives from the wind energy industry to obtain input on the Five-Year Research Plan then being prepared by DOE. One specific suggestion that came out of these meetings was that the federal program should conduct cooperative research tests with industry to enhance the technology transfer process. It was also felt that the active involvement of industry in DOE-funded research would improve the state of the art of wind turbine technology. DOE established the Cooperative Field Test Program (CFTP) in response to that suggestion. This program was one of the first in DOE to feature joint industry-government research test teams working toward common objectives.

  18. Design and Field Test of a Galvanometer Deflected Streak Camera

    Energy Technology Data Exchange (ETDEWEB)

    Lai, C C; Goosman, D R; Wade, J T; Avara, R

    2002-11-08

    We have developed a compact fieldable optically-deflected streak camera first reported in the 20th HSPP Congress. Using a triggerable galvanometer that scans the optical signal, the imaging and streaking function is an all-optical process without incurring any photon-electron-photon conversion or photoelectronic deflection. As such, the achievable imaging quality is limited mainly only by optical design, rather than by multiple conversions of signal carrier and high voltage electron-optics effect. All core elements of the camera are packaged into a 12 inch x 24 inch footprint box, a size similar to that of a conventional electronic streak camera. At LLNL's Site-300 Test Site, we have conducted a Fabry-Perot interferometer measurement of fast object velocity using this all-optical camera side-by-side with an intensified electronic streak camera. These two cameras are configured as two independent instruments for recording synchronously each branch of the 50/50 splits from one incoming signal. Given the same signal characteristics, the test result has undisputedly demonstrated superior imaging performance for the all-optical streak camera. It produces higher signal sensitivity, wider linear dynamic range, better spatial contrast, finer temporal resolution, and larger data capacity as compared with that of the electronic counterpart. The camera had also demonstrated its structural robustness and functional consistence to be well compatible with field environment. This paper presents the camera design and the test results in both pictorial records and post-process graphic summaries.

  19. A study of production/injection data from slim holes and large-diameter wells at the Takigami Geothermal Field, Kyushu, Japan

    Energy Technology Data Exchange (ETDEWEB)

    Garg, S.K. [Maxwell Federal Div., Inc., San Diego, CA (United States); Combs, J. [Geo-Hills Associates, Los Altos Hills, CA (United States); Azawa, Fumio [Idemitsu Kosan Co. Ltd., Tokyo (Japan); Gotoh, Hiroki [Idemitsu Oita Geothermal Co. Ltd., Oita (Japan)

    1996-11-01

    Production and injection data from nine slim holes and sixteen large-diameter wells at the Takigami Geothermal Field, Kyushu, Japan were analyzed in order to establish relationships (1) between injectivity and productivity indices, (2) between productivity/injectivity index and borehole diameter, and (3) between discharge capacity of slim holes and large-diameter wells. Results are compared with those from the Oguni and Sumikawa fields. A numerical simulator (WELBOR) was used to model the available discharge rate from Takigami boreholes. The results of numerical modeling indicate that the flow rate of large-diameter geothermal production wells with liquid feedzones can be predicted using data from slim holes. These results also indicate the importance of proper well design.

  20. Test particle transport in perturbed magnetic fields in tokamaks

    NARCIS (Netherlands)

    de Rover, M.; Schilham, A.M.R.; Montvai, A.; Cardozo, N. J. L.

    1999-01-01

    Numerical calculations of magnetic field line trajectories in a tokamak are used to investigate the common hypotheses that (i) field lines in a chaotic field make a Gaussian random walk and (ii) that the poloidal component of the magnetic field is uniform in regions with a chaotic magnetic field. Bo

  1. The IsoDAR High Intensity H$_2^+$ Transport and Injection Tests

    CERN Document Server

    Alonso, Jose; Calabretta, Luciano; Campo, Daniela; Celona, Luigi; Conrad, Janet M; Day, Alexandra; Castro, Giuseppe; Labrecque, Francis; Winklehner, Daniel

    2015-01-01

    This technical report reviews the tests performed at the Best Cyclotron Systems, Inc. facility in regards to developing a cost effective ion source, beam line transport system, and acceleration system capable of high H$_2^+$ current output for the IsoDAR (Isotope Decay At Rest) experiment. We begin by outlining the requirements for the IsoDAR experiment then provide overview of the Versatile Ion Source, Low Energy Beam Transport system, spiral inflector, and cyclotron. The experimental measurements are then discussed and the results are compared with a thorough set of simulation studies. Of particular importance we note that the Versatile Ion Source (VIS) proved to be a reliable ion source capable of generating a large amount of H$_2^+$ current. The results suggest that with further upgrades, the VIS could potentially be a suitable candidate for IsoDAR. The conclusion outlines the key results from our tests and introduces the forthcoming work this technical report has motivated.

  2. Field-Amplified Sample Injection-Micellar Electrokinetic Chromatography for the Determination of Benzophenones in Food Simulants

    Directory of Open Access Journals (Sweden)

    Cristina Félez

    2015-07-01

    Full Text Available A field-amplified sample injection-micellar electrokinetic chromatography (FASI-MEKC method for the determination of 14 benzophenones (BPs in a food simulant used in migration studies of food packaging materials was developed, allowing almost baseline separation in less than 21 min. The use of a 10 mM sodium dodecyl sulfate (SDS solution as sample matrix was mandatory to achieve FASI enhancement of the analyzed BPs. A 21- to 784-fold sensitivity enhancement was achieved with FASI-MEKC, obtaining limits of detection down to 5.1–68.4 µg/L, with acceptable run-to-run precisions (RSD values lower than 22.3% and accuracy (relative errors lower than 21.0%. Method performance was evaluated by quantifying BPs in the food simulant spiked at 500 µg/L (bellow the established specific migration limit for BP (600 µg/L by EU legislation. For a 95% confidence level, no statistical differences were observed between found and spiked concentrations (probability at the confidence level, p value, of 0.55, showing that the proposed FASI-MEKC method is suitable for the analysis of BPs in food packaging migration studies at the levels established by EU legislation.

  3. Nonlinear Burn Control in Tokamaks using Heating, Non-axisymmetric Magnetic Fields, Isotopic fueling and Impurity injection

    Science.gov (United States)

    Pajares, Andres; Schuster, Eugenio

    2016-10-01

    Plasma density and temperature regulation in future tokamaks such as ITER is arising as one of the main problems in nuclear-fusion control research. The problem, known as burn control, is to regulate the amount of fusion power produced by the burning plasma while avoiding thermal instabilities. Prior work in the area of burn control considered different actuators, such as modulation of the auxiliary power, modulation of the fueling rate, and controlled impurity injection. More recently, the in-vessel coil system was suggested as a feasible actuator since it has the capability of modifying the plasma confinement by generating non-axisymmetric magnetic fields. In this work, a comprehensive, model-based, nonlinear burn control strategy is proposed to integrate all the previously mentioned actuators. A model to take into account the influence of the in-vessel coils on the plasma confinement is proposed based on the plasma collisionality and the density. A simulation study is carried out to show the capability of the controller to drive the system between different operating points while rejecting perturbations. Supported by the US DOE under DE-SC0010661.

  4. Understanding the interaction of injected CO2 and reservoir fluids in the Cranfield enhanced oil recovery (EOR) field (MS, USA) by non-radiogenic noble gas isotopes

    Science.gov (United States)

    Gyore, Domokos; Stuart, Finlay; Gilfillan, Stuart

    2016-04-01

    Identifying the mechanism by which the injected CO2 is stored in underground reservoirs is a key challenge for carbon sequestration. Developing tracing tools that are universally deployable will increase confidence that CO2 remains safely stored. CO2 has been injected into the Cranfield enhanced oil recovery (EOR) field (MS, USA) since 2008 and significant amount of CO2 has remained (stored) in the reservoir. Noble gases (He, Ne, Ar, Kr, Xe) are present as minor natural components in the injected CO2. He, Ne and Ar previously have been shown to be powerful tracers of the CO2 injected in the field (Györe et al., 2015). It also has been implied that interaction with the formation water might have been responsible for the observed CO2 loss. Here we will present work, which examines the role of reservoir fluids as a CO2 sink by examining non-radiogenic noble gas isotopes (20Ne, 36Ar, 84Kr, 132Xe). Gas samples from injection and production wells were taken 18 and 45 months after the start of injection. We will show that the fractionation of noble gases relative to Ar is consistent with the different degrees of CO2 - fluid interaction in the individual samples. The early injection samples indicate that the CO2 injected is in contact with the formation water. The spatial distribution of the data reveal significant heterogeneity in the reservoir with some wells exhibiting a relatively free flow path, where little formation water is contacted. Significantly, in the samples, where CO2 loss has been previously identified show active and ongoing contact. Data from the later stage of the injection shows that the CO2 - oil interaction has became more important than the CO2 - formation water interaction in controlling the noble gas fingerprint. This potentially provides a means to estimate the oil displacement efficiency. This dataset is a demonstration that noble gases can resolve CO2 storage mechanisms and its interaction with the reservoir fluids with high resolution

  5. Results from laboratory and field testing of nitrate measuring spectrophotometers

    Science.gov (United States)

    Snazelle, Teri T.

    2015-01-01

    Five ultraviolet (UV) spectrophotometer nitrate analyzers were evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) during a two-phase evaluation. In Phase I, the TriOS ProPs (10-millimeter (mm) path length), Hach NITRATAX plus sc (5-mm path length), Satlantic Submersible UV Nitrate Analyzer (SUNA, 10-mm path length), and S::CAN Spectro::lyser (5-mm path length) were evaluated in the HIF Water-Quality Servicing Laboratory to determine the validity of the manufacturer's technical specifications for accuracy, limit of linearity (LOL), drift, and range of operating temperature. Accuracy specifications were met in the TriOS, Hach, and SUNA. The stock calibration of the S::CAN required two offset adjustments before the analyzer met the manufacturer's accuracy specification. Instrument drift was observed only in the S::CAN and was the result of leaching from the optical path insert seals. All tested models, except for the Hach, met their specified LOL in the laboratory testing. The Hach's range was found to be approximately 18 milligrams nitrogen per liter (mg-N/L) and not the manufacturer-specified 25 mg-N/L. Measurements by all of the tested analyzers showed signs of hysteresis in the operating temperature tests. Only the SUNA measurements demonstrated excessive noise and instability in temperatures above 20 degrees Celsius (°C). The SUNA analyzer was returned to the manufacturer at the completion of the Phase II field deployment evaluation for repair and recalibration, and the performance of the sensor improved significantly.

  6. Parametric effect on the mixing of the combination of a hydrogen porthole with an air porthole in transverse gaseous injection flow fields

    Science.gov (United States)

    Li, Lang-quan; Huang, Wei; Yan, Li; Li, Shi-bin

    2017-10-01

    The dual transverse injection system with a front hydrogen porthole and a rear air porthole arranged in tandem is proposed, and this is a realistic approach for mixing enhancement and penetration improvement of transverse injection in a scramjet combustor. The influence of this dual transverse injection system on mixing characteristics has been evaluated numerically based on grid independency analysis and code validation. The numerical approach employed in the current study has been validated against the available experimental data in the open literature, and the predicted wall static pressure distributions show reasonable agreement with the experimental data for the cases with different jet-to-crossflow pressure ratios. The obtained results predicted by the three-dimensional Reynolds-average Navier - Stokes (RANS) equations coupled with the two equation k-ω shear stress transport (SST) turbulence model show that the air pothole has an great impact on penetration depth and mixing efficiency, and the effect of air jet on flow field varies with different values of the aspect ratio. The air porthole with larger aspect ratio can increase the fuel penetration depth. However, when the aspect ratio is relatively small, the fuel penetration depth decreases, and even smaller than that of the single injection system. At the same time, the air pothole has a highly remarkable improvement on mixing efficiency, especially in the near field. The smaller the aspect ratio of the air porthole is, the higher the mixing efficiency in the near field is. This is due to its larger circulation in the near field. The dual injection system owns more losses of stagnation pressure than the single injection system.

  7. Testing Einstein's Equivalence Principle with supercluster Laniakea's gravitational field

    Science.gov (United States)

    Luo, Zhi-Xing; Zhang, Bo; Wei, Jun-Jie; Wu, Xue-Feng

    2016-03-01

    Comparing the parameterized post-Newtonian parameter γ values for different types of particles, or the same type of particles with different energies is an important method to test the Einstein Equivalence Principle (EEP). Assuming that the observed time delays are dominated by the gravitational potential of the Laniakea supercluster of galaxies, better results of EEP constraints can be obtained. In this paper, we apply photons from three kinds of cosmic transients, including TeV blazars, gamma-ray bursts as well as fast radio bursts to constrain EEP. With a gravitational field far more stronger than a single galaxy, we obtain 4-5 orders of magnitude more stringent than the previous results.

  8. Testing Einstein's Equivalence Principle with Supercluster Laniakea's Gravitational Field

    CERN Document Server

    Luo, Zhi-Xing; Wei, Jun-Jie; Wu, Xue-Feng

    2016-01-01

    Comparing the parameterized post-Newtonian parameter $\\gamma$ values for different types of particles, or the same type of particles with different energies is an important method to test the Einstein Equivalence Principle (EEP). Assuming that the observed time delays are dominated by the gravitational potential of the Laniakea supercluster of galaxies, better results of EEP constraints can be obtained. In this paper, we apply photons from three kinds of cosmic transients, including TeV blazars, gamma-ray bursts as well as fast radio bursts to constrain EEP. With a gravitational field far more stronger than a single galaxy, we obtain 4--5 orders of magnitude more stringent than the pervious results.

  9. Numerical Tests of Fast Reconnection in Weakly Stochastic Magnetic Fields

    CERN Document Server

    Kowal, G; Vishniac, E T; Otmianowska-Mazur, K

    2009-01-01

    We study the effects of turbulence on magnetic reconnection using 3D numerical simulations. This is the first attempt to test a model of fast magnetic reconnection in the presence of weak turbulence proposed by Lazarian & Vishniac (1999). This model predicts that weak turbulence, generically present in most of astrophysical systems, enhances the rate of reconnection by reducing the transverse scale for reconnection events and by allowing many independent flux reconnection events to occur simultaneously. As a result the reconnection speed becomes independent of Ohmic resistivity and is determined by the magnetic field wandering induced by turbulence. To quantify the reconnection speed we use both an intuitive definition, i.e. the speed of the reconnected flux inflow, as well as a more sophisticated definition based on a formally derived analytical expression. Our results confirm the predictions of the Lazarian & Vishniac model. In particular, we find that Vrec Pinj^(1/2), as predicted by the model. The...

  10. A field test of a simple stochastic radiative transfer model

    Energy Technology Data Exchange (ETDEWEB)

    Byrne, N. [Science Applications International Corp., San Diego, CA (United States)

    1995-09-01

    The problem of determining the effect of clouds on the radiative energy balance of the globe is of well-recognized importance. One can in principle solve the problem for any given configuration of clouds using numerical techniques. This knowledge is not useful however, because of the amount of input data and computer resources required. Besides, we need only the average of the resulting solution over the grid scale of a general circulation model (GCM). Therefore, we are interested in estimating the average of the solutions of such fine-grained problems using only coarse grained data, a science or art called stochastic radiation transfer. Results of the described field test indicate that the stochastic description is a somewhat better fit to the data than is a fractional cloud cover model, but more data are needed. 1 ref., 3 figs.

  11. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    Energy Technology Data Exchange (ETDEWEB)

    Susan S. Sorini; John F. Schabron; Joseph F. Rovani, Jr.

    2002-09-30

    Western Research Institute (WRI) has developed a new commercial product ready for technology transfer, the Diesel Dog{reg_sign} Portable Soil Test Kit, for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated as ASTM Method D 5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In June 2001, the Diesel Dog technology won an American Chemical Society Regional Industrial Innovations Award. To gain field experience with the new technology, Diesel Dog kits have been used for a variety of site evaluation and cleanup activities. Information gained from these activities has led to improvements in hardware configurations and additional insight into correlating Diesel Dog results with results from laboratory methods. The Wyoming Department of Environmental Quality (DEQ) used Diesel Dog Soil Test Kits to guide cleanups at a variety of sites throughout the state. ENSR, of Acton, Massachusetts, used a Diesel Dog Portable Soil Test Kit to evaluate sites in the Virgin Islands and Georgia. ChemTrack and the U.S. Army Corps of Engineers successfully used a test kit to guide excavation at an abandoned FAA fuel-contaminated site near Fairbanks, Alaska. Barenco, Inc. is using a Diesel Dog Portable Soil Test Kit for site evaluations in Canada. A small spill of diesel fuel was cleaned up in Laramie, Wyoming using a Diesel

  12. Field test on temperature field and thermal stress for prestressed concrete box-girder bridge

    Institute of Scientific and Technical Information of China (English)

    Baoguo CHEN; Rui DING; Junjie ZHENG; Shibiao ZHANG

    2009-01-01

    A field test was conducted to investigate the distribution of temperature field and the variation of thermal stress for a prestressed concrete (PC) box-girder bridge. The change of hydration heat temperature consists of four periods: temperature rising period, constant temperature period, rapid temperature fall period and stow temperature fall period. The peak value of hydration heat temperature increases with the increasing casting temperature of concrete; the relation between them is approximately linear. According to field tests, the thermal stress incurred by hydration heat may induce temperature cracks on the PC box-girder. Furthermore, the nonlinear distribution of temperature gradient and the fluctuation of thermal stress induced by exposure to sunlight were also obtained based on continuous in-situ monitoring. Such results show that the prevailing Chinese Code (2004) is insufficient since it does not take into account the temperature gradient of the bottom slab. Finally, some preventive measures against temperature cracks were proposed based on related studies. The conclusions can provide valuable reference for the design and construction of PC box-girder bridges.

  13. Microinjection manipulation resulted in the increased apoptosis of spermatocytes in testes from intracytoplasmic sperm injection (ICSI derived mice.

    Directory of Open Access Journals (Sweden)

    Yang Yu

    Full Text Available The invention of intracytoplasmic sperm injection (ICSI has possibly been the most important development in reproductive medicine, one that has given hope to thousands of infertile couples worldwide. However, concerns remain regarding the safety of this method since it is a more invasive procedure than in vitro fertilization (IVF, since a spermatozoon is injected into the oocyte cytoplasm. Using mice derived from IVF technology as a control, we assessed the influence of invasive microinjection in the process of transferring sperm into oocyte cytoplasm in ICSI procedure on the development and physiologic function of resultant offspring. Our results demonstrated that mice produced from ICSI and IVF had no significant difference in phenotypic indices including body weight, forelimb physiology, and learning and memory ability. However, increased spermatocyte apoptosis was observed in the testis of adult ICSI mice, when compared with IVF mice. And, decreased testis weight and marked damage of spermatogenic epithelia were found in aged ICSI mice. Furthermore, proteomic analysis verified that most of the differentiated proteins in testes between adult ICSI and IVF mice were those involved in regulation of apoptosis pathways. Our results demonstrated that the microinjection manipulation used in the ICSI procedure might pose potential risks to the fertility of male offspring. The changed expression of a series of proteins relating to apoptosis or proliferation might contribute to it. Further studies are necessary to better understand all the risks of ICSI.

  14. Testing neoclassical competitive market theory in the field.

    Science.gov (United States)

    List, John A

    2002-11-26

    This study presents results from a pilot field experiment that tests predictions of competitive market theory. A major advantage of this particular field experimental design is that my laboratory is the marketplace: subjects are engaged in buying, selling, and trading activities whether I run an exchange experiment or am a passive observer. In this sense, I am gathering data in a natural environment while still maintaining the necessary control to execute a clean comparison between treatments. The main results of the study fall into two categories. First, the competitive model predicts reasonably well in some market treatments: the expected price and quantity levels are approximated in many market rounds. Second, the data suggest that market composition is important: buyer and seller experience levels impact not only the distribution of rents but also the overall level of rents captured. An unexpected result in this regard is that average market efficiency is lowest in markets that match experienced buyers and experienced sellers and highest when experienced buyers engage in bargaining with inexperienced sellers. Together, these results suggest that both market experience and market composition play an important role in the equilibrium discovery process.

  15. Controlling charge injection by self-assembled monolayers in bottom-gate and top-gate organic field-effect transistors

    NARCIS (Netherlands)

    Gholamrezaie, F.; Asadi, K.; Kicken, R.A.H.J.; Langeveld-Voss, B.M.W.; Leeuw, D.M. de; Blom, P.W.M.

    2011-01-01

    We investigate the modulation of the charge injection in organic field-effect transistors with self-assembled monolayers (SAMs) using both a bottom-gate and a top-gate geometry. The current modulation by using SAMs is more pronounced in the top-gate geometry due to the better defined upper surface o

  16. Design and properties of a flow-injection analysis cell using potassium-selective ionsensitive field-effect transistors as detection elements

    NARCIS (Netherlands)

    van der Wal, Peter D.; van der Wal, P.D.; Sudhölter, Ernst J.R.; Sudholter, Ernst; Reinhoudt, David

    1991-01-01

    The combination of flow-injection analysis (FIA) and chemically modified ion-sensitive field-effect transistors (CHEMFETs) is described. In a wall-jet cell, two identical potassium-selective CHEMFETs were used for a differential measurement using a platinum (pseudo-)reference electrode.

  17. Vadose Zone Transport Field Study: Detailed Test Plan for Simulated Leak Tests

    Energy Technology Data Exchange (ETDEWEB)

    Ward, Anderson L.; Gee, Glendon W.

    2000-06-23

    This report describes controlled transport experiments at well-instrumented field tests to be conducted during FY 2000 in support of DOE?s Vadose Zone Transport Field Study (VZTFS). The VZTFS supports the Groundwater/Vadose Zone Integration Project Science and Technology Initiative. The field tests will improve understanding of field-scale transport and lead to the development or identification of efficient and cost-effective characterization methods. These methods will capture the extent of contaminant plumes using existing steel-cased boreholes. Specific objectives are to 1) identify mechanisms controlling transport processes in soils typical of the hydrogeologic conditions of Hanford?s waste disposal sites; 2) reduce uncertainty in conceptual models; 3) develop a detailed and accurate data base of hydraulic and transport parameters for validation of three-dimensional numerical models; and 4) identify and evaluate advanced, cost-effective characterization methods with the potential to assess changing conditions in the vadose zone, particularly as surrogates of currently undetectable high-risk contaminants. Pacific Northwest National Laboratory (PNNL) manages the VZTFS for DOE.

  18. Evaluation of the reliability of two field hockey specific sprint and dribble tests in young field hockey players

    NARCIS (Netherlands)

    Lemmink, K.A.; Elferink-Gemser, M.T.; Visscher, C.

    2004-01-01

    OBJECTIVES: To determine the reliability of two field hockey specific tests: the shuttle sprint and dribble test (ShuttleSDT) and the slalom sprint and dribble test (SlalomSDT). METHODS: The shuttle sprint and dribble performances of 22 young male and 12 young female field hockey players were

  19. Evaluation of the reliability of two field hockey specific sprint and dribble tests in young field hockey players

    NARCIS (Netherlands)

    Lemmink, K.A.; Elferink-Gemser, M.T.; Visscher, C.

    2004-01-01

    OBJECTIVES: To determine the reliability of two field hockey specific tests: the shuttle sprint and dribble test (ShuttleSDT) and the slalom sprint and dribble test (SlalomSDT). METHODS: The shuttle sprint and dribble performances of 22 young male and 12 young female field hockey players were assess

  20. Development of a specific anaerobic field test for aerobic gymnastics.

    Science.gov (United States)

    Alves, Christiano Robles Rodrigues; Borelli, Marcello Tadeu Caetano; Paineli, Vitor de Salles; Azevedo, Rafael de Almeida; Borelli, Claudia Cristine Gomes; Lancha Junior, Antônio Herbert; Gualano, Bruno; Artioli, Guilherme Giannini

    2015-01-01

    The current investigation aimed to develop a valid specific field test to evaluate anaerobic physical performance in Aerobic Gymnastics athletes. We first designed the Specific Aerobic Gymnast Anaerobic Test (SAGAT), which included gymnastics-specific elements performed in maximal repeated sprint fashion, with a total duration of 80-90 s. In order to validate the SAGAT, three independent sub-studies were performed to evaluate the concurrent validity (Study I, n=8), the reliability (Study II, n=10) and the sensitivity (Study III, n=30) of the test in elite female athletes. In Study I, a positive correlation was shown between lower-body Wingate test and SAGAT performance (Mean power: p = 0.03, r = -0.69, CI: -0.94 to 0.03 and Peak power: p = 0.02, r = -0.72, CI: -0.95 to -0.04) and between upper-body Wingate test and SAGAT performance (Mean power: p = 0.03, r = -0.67, CI: -0.94 to 0.02 and Peak power: p = 0.03, r = -0.69, CI: -0.94 to 0.03). Additionally, plasma lactate was similarly increased in response to SAGAT (p = 0.002), lower-body Wingate Test (p = 0.021) and a simulated competition (p = 0.007). In Study II, no differences were found between the time to complete the SAGAT in repeated trials (p = 0.84; Cohen's d effect size = 0.09; ICC = 0.97, CI: 0.89 to 0.99; MDC95 = 0.12 s). Finally, in Study III the time to complete the SAGAT was significantly lower during the competition cycle when compared to the period before the preparatory cycle (p Gymnastics training period. Taken together, these data have demonstrated that SAGAT is a specific, reliable and sensitive measurement of specific anaerobic performance in elite female Aerobic Gymnastics, presenting great potential to be largely applied in training settings.

  1. Time-lapse walkaway VSP imaging using reverse-time migration in the angle domain for monitoring CO2 injection at the SACROC EOR field

    Science.gov (United States)

    Huang, L.; Huang, H.

    2012-12-01

    Time-lapse walkaway vertical seismic profiling (VSP) surveys can reveal important reservoir changes caused by CO2 injection. We study the capability of time-lapse walkaway VSP imaging using reverse-time migration in the angle-domain for monitoring CO2 injection. During the Phase II project of the Southwest Regional Partnership on Carbon Sequestration, one baseline and one repeat walkaway VSP surveys were conducted in 2008 and 2009, respectively, at the SACROC enhanced oil recovery (EOR) field for monitoring CO2 injection. The datasets were acquired by Baker Atlas in collaboration with Kinder Morgan. In this study, we apply reverse-time migration in the angle domain to the time-lapse walkaway VSP datasets from the SACROC EOR field, and conduct detailed analyses of common-image gathers. Our migration results demonstrate that reverse-time migration in the angle domain produces images of time-lapse walkaway VSP data with a better image quality compared to those obtained using conventional reverse-time migration. The time-lapse image difference along the bottom of the reservoir where CO2 is injected is much more significant than that along the top of the reservoir. This is partially because we use the same baseline velocity model for migrations of both datasets. The reservoir velocity decreases during CO2 injection, leading to slightly change in the migration image location along the bottom of the reservoir for the repeat VSP data.

  2. In situ, field-scale evaluation of surfactant-enhanced DNAPL recovery using a single-well, ``push-pull'' test

    Energy Technology Data Exchange (ETDEWEB)

    Istok, J.D.; Field, J.A.

    1999-10-01

    The overall goal of this project was to further develop the single-well, ``push-pull'' test method as a feasibility assessment and site-characterization tool for studying the fundamental fate and transport behavior of injected surfactants and their ability to solubilize and mobilize dense nonaqueous phase liquids (DNAPLs) in the subsurface. The specific objectives were to develop a modified push-pull test for use in identifying and quantifying the effects of sorption, precipitation, and biodegradation on the fate and transport of injected surfactants, use the developed test method to quantify the effects of these processes on the ability of injected surfactants to solubilize and mobilize residual phase trichloroethane (TCE), and demonstrate the utility of the developed test method for performing site characterization and feasibility studies for surfactant-enhanced DNAPL recovery systems in the field. The results from the intermediate-scale laboratory experiments conducted for this project indicate that the single-well, push-pull test method can provide quantitative information on the effectiveness of injected surfactants in enhancing DNAPL solubilization in natural aquifer sediments. Specifically, the results of this research demonstrate the ability of the single-well, push-pull test to characterize the behavior of multi-component surfactants in the presence of natural aquifer sediment under laboratory and in-situ field conditions.

  3. Title: Benchmark of the radiation field simulations of the LHC injection lines with the RadMon detectors

    CERN Document Server

    Boccone, V; Kramer, D; Roeed, K

    2011-01-01

    In this paper we present the high energy hadron (HEH) fluence simulations in the LHC injection regions (TI2 and TI8) performed by the FLUKA Monte-Carlo code and we compare the expected nominal single event upset (SEU) counts in the RadMon detectors with the measured values. During the LHC injection setup the 450 GeV/c proton beam from the Super Proton Synchrotron (SPS) is progressively adjusted and aligned through the two injection lines until the LHC septum magnets. During the first phase of alignment the beam is dumped onto the injection line dumps TEDs and the debris of the interactions streams trough junction tunnel which contains sensitive electronic equipment. In the case of the TI8 injection lines also the losses on the TCDIH.87904 collimator might represent a problem for the electronics in the UJ87 tunnel.

  4. Field-Based Video Pre-Test Counseling, Oral Testing, and Telephonic Post-Test Counseling: Implementation of an HIV Field Testing Package among High-Risk Indian Men

    Science.gov (United States)

    Snyder, Hannah; Yeldandi, Vijay V.; Kumar, G. Prem; Liao, Chuanhong; Lakshmi, Vemu; Gandham, Sabitha R.; Muppudi, Uma; Oruganti, Ganesh; Schneider, John A.

    2012-01-01

    In India, men who have sex with men (MSM) and truck drivers are high-risk groups that often do not access HIV testing due to stigma and high mobility. This study evaluated a field testing package (FTP) that identified HIV positive participants through video pre-test counseling, OraQuick oral fluid HIV testing, and telephonic post-test counseling…

  5. Evaluation of thermal performance in fields subjected to steam injection (SW-SAGD mode), Orinoco oil belt, Venezuela

    Energy Technology Data Exchange (ETDEWEB)

    Armas, F.; Mago, R.; Franco, L.; Rodriguez, J.; Gil, E. [PDVSA EandP (Venezuela)

    2011-07-01

    The first well to operate the SW-SAGD process in the Orinoco oil belt in Venezuela was built in 2006 by Petroleos de Venezuela S.A (PDVSA). SW-SAGD is a thermal recovery process consisting in the injection of steam through a horizontal well pipe insulation. In order to follow the behavior of steam and the movement of heated fluids in such a process better, PDVSA installed a monitoring system composed of high temperature fiber optic and thermocouple type sensors. The aim of this paper is to assess the thermal behavior of reservoirs in wells under the SW-SAGD process. A pilot test has been conducted over the last 3 years. Results show an increase in production and estimations show a recovery factor twice as high as in other wells. This study demonstrated that SW-SAGD is an excellent alternative solution to stimulate reservoirs in the Orinoco oil belt and valuable information on the reservoir's thermal behavior was established.

  6. Advanced Rooftop Control (ARC) Retrofit: Field-Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Weimin; Katipamula, Srinivas; Ngo, Hung; Underhill, Ronald M.; Taasevigen, Danny J.; Lutes, Robert G.

    2013-07-31

    The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

  7. First Field Test of FiDeL the Magnetic Field Description for the LHC

    CERN Document Server

    Bottura, L; Catalan-Lasheras, N; Deniau, L; Di Castro, M; Giovannozzi, M; Hagen, P; Koutchouk, J; Lamont, M; Miles, J; Remondino, V; Sammut, N; Sanfilippo, S; Schmidt, F; Sernelius, D; Strzelczyk, M; Todesco, E; Venturini-Delsolaro, W; Walckiers, L; Wolf, R; Xydi, P

    2009-01-01

    The start-up of the LHC has provided the first field test for the concept, functionality and accuracy of FiDeL, the Field Description for the LHC. FiDeL is primarily a parametric model of the transfer function of the main field integrals generated by the series of magnets in the LHC powering circuits, from main optical elements to high-order harmonic correctors, both superconducting and normal-conducting magnets. In addition, the same framework is used to predict harmonic errors of both static and dynamic nature, and forecast appropriate corrections. In this paper we give a description of the level of detail achieved in the model and the rationale adopted for the LHC start-up. Beam-based measurements have been used for an assessment of the first-shot accuracy in the prediction of the current setting for the main arc magnets. We finally give a list of priority issues to be addressed, and sketch a plan for the preparation of the LHC restart.

  8. The direct injection of intense ion beams from a high field electron cyclotron resonance ion source into a radio frequency quadrupole.

    Science.gov (United States)

    Rodrigues, G; Becker, R; Hamm, R W; Baskaran, R; Kanjilal, D; Roy, A

    2014-02-01

    The ion current achievable from high intensity ECR sources for highly charged ions is limited by the high space charge. This makes classical extraction systems for the transport and subsequent matching to a radio frequency quadrupole (RFQ) accelerator less efficient. The direct plasma injection (DPI) method developed originally for the laser ion source avoids these problems and uses the combined focusing of the gap between the ion source and the RFQ vanes (or rods) and the focusing of the rf fields from the RFQ penetrating into this gap. For high performance ECR sources that use superconducting solenoids, the stray magnetic field of the source in addition to the DPI scheme provides focusing against the space charge blow-up of the beam. A combined extraction/matching system has been designed for a high performance ECR ion source injecting into an RFQ, allowing a total beam current of 10 mA from the ion source for the production of highly charged (238)U(40+) (1.33 mA) to be injected at an ion source voltage of 60 kV. In this design, the features of IGUN have been used to take into account the rf-focusing of an RFQ channel (without modulation), the electrostatic field between ion source extraction and the RFQ vanes, the magnetic stray field of the ECR superconducting solenoid, and the defocusing space charge of an ion beam. The stray magnetic field is shown to be critical in the case of a matched beam.

  9. The direct injection of intense ion beams from a high field electron cyclotron resonance ion source into a radio frequency quadrupole

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, G., E-mail: gerosro@gmail.com; Kanjilal, D.; Roy, A. [Inter University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi (India); Becker, R. [Institut fur Angewandte Physik der Universitaet, D-60054 Frankfurt/M (Germany); Hamm, R. W. [R and M Technical Enterprises, Inc., 4725 Arlene Place, Pleasanton, California 94566 (United States); Baskaran, R. [Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu (India)

    2014-02-15

    The ion current achievable from high intensity ECR sources for highly charged ions is limited by the high space charge. This makes classical extraction systems for the transport and subsequent matching to a radio frequency quadrupole (RFQ) accelerator less efficient. The direct plasma injection (DPI) method developed originally for the laser ion source avoids these problems and uses the combined focusing of the gap between the ion source and the RFQ vanes (or rods) and the focusing of the rf fields from the RFQ penetrating into this gap. For high performance ECR sources that use superconducting solenoids, the stray magnetic field of the source in addition to the DPI scheme provides focusing against the space charge blow-up of the beam. A combined extraction/matching system has been designed for a high performance ECR ion source injecting into an RFQ, allowing a total beam current of 10 mA from the ion source for the production of highly charged {sup 238}U{sup 40+} (1.33 mA) to be injected at an ion source voltage of 60 kV. In this design, the features of IGUN have been used to take into account the rf-focusing of an RFQ channel (without modulation), the electrostatic field between ion source extraction and the RFQ vanes, the magnetic stray field of the ECR superconducting solenoid, and the defocusing space charge of an ion beam. The stray magnetic field is shown to be critical in the case of a matched beam.

  10. The direct injection of intense ion beams from a high field electron cyclotron resonance ion source into a radio frequency quadrupole

    Science.gov (United States)

    Rodrigues, G.; Becker, R.; Hamm, R. W.; Baskaran, R.; Kanjilal, D.; Roy, A.

    2014-02-01

    The ion current achievable from high intensity ECR sources for highly charged ions is limited by the high space charge. This makes classical extraction systems for the transport and subsequent matching to a radio frequency quadrupole (RFQ) accelerator less efficient. The direct plasma injection (DPI) method developed originally for the laser ion source avoids these problems and uses the combined focusing of the gap between the ion source and the RFQ vanes (or rods) and the focusing of the rf fields from the RFQ penetrating into this gap. For high performance ECR sources that use superconducting solenoids, the stray magnetic field of the source in addition to the DPI scheme provides focusing against the space charge blow-up of the beam. A combined extraction/matching system has been designed for a high performance ECR ion source injecting into an RFQ, allowing a total beam current of 10 mA from the ion source for the production of highly charged 238U40+ (1.33 mA) to be injected at an ion source voltage of 60 kV. In this design, the features of IGUN have been used to take into account the rf-focusing of an RFQ channel (without modulation), the electrostatic field between ion source extraction and the RFQ vanes, the magnetic stray field of the ECR superconducting solenoid, and the defocusing space charge of an ion beam. The stray magnetic field is shown to be critical in the case of a matched beam.

  11. Processes Affecting the Trihalomethane Concentrations Associated with the Third Injection, Storage, and Recovery Test at Lancaster, Antelope Valley, California, March 1998 through April 1999

    Science.gov (United States)

    Fram, Miranda S.; Bergamaschi, Brian A.; Goodwin, Kelly D.; Fujii, Roger; Clark, Jordan F.

    2003-01-01

    The formation and fate of trihalomethanes (THM) during the third injection, storage, and recovery test at Lancaster, Antelope Valley, California, were investigated as part of a program to assess the long-term feasibility of using injection, storage, and recovery as a water-supply method and as a way to reduce water-level declines and land-subsidence in the Antelope Valley. The program was conducted by the U.S. Geological Survey in cooperation with the Los Angeles County Department of Public Works and the Antelope Valley-East Kern Water Agency. The water used for injection, storage, and recovery must be disinfected before injection and thus contains THMs and other disinfection by-products. THMs (chloroform, CHCl3, bromodichloromethane, CHCl2Br, dibromochloromethane, CHClBr2, and bromoform, CHBr3) are formed by reaction between natural dissolved organic carbon that is present in water and chlorine that is added during the disinfection step of the drinking water treatment process. THMs are carcinogenic compounds, and their concentrations in drinking water are regulated by the U.S. Environmental Protection Agency. During previous cycles of the Lancaster program, extracted water still contained measurable concentrations of THMs long after continuous pumping had extracted a greater volume of water than had been injected. This raised concerns about the potential long-term effect of injection, storage, and recovery cycles on ground-water quality in Antelope Valley aquifers. The primary objectives of this investigation were to determine (1) what controlled continued THM formation in the aquifer after injection, (2) what caused of the persistence of THMs in the extracted water, even after long periods of pumping, (3) what controlled the decrease of THM concentrations during the extraction period, and (4) the potential for natural attenuation of THMs in the aquifer. Laboratory experiments on biodegradation of THMs in microcosms of aquifer materials indicate that aquifer

  12. Field Testing of High Current Electrokinetic Nanoparticle Treatment for Corrosion Mitigation in Reinforced Concrete

    Science.gov (United States)

    Calle, Luz Marina; Alexander, Joshua B.; Cardenas, Henry E.; Kupwade-Patil, Kunal

    2008-01-01

    This work examines field performance of nanoscale pozzolan treatments delivered el ctrokinetically to suppress chloride induced corrosion of concrete reinforcement. The particles are 20 nm silica spheres coated with 2 nm alumina particles that carry a net positive charge. Earlier work demonstrated that the alumina particles were stripped from the silica carriers and formed a dense phase with an interparticle spacing that is small enough to inhibit the transport of solvated chlorides. A D.C. field was used to inject the particles into the pores of concrete specimens, directly toward the mild steel bars that were embedded within each 3 inch diameter by 6 inch length concrete specimen. The voltage was held constant at 25 v per inch of concrete cover for a period of 7 days. These voltages permitted current densities as high as 3 A/sq m. During the final 3 days, a 1 molar solution of calcium nitrate tetrahydrate was used to provide a source of calcium to facilitate stronger and more densified phase formation within the pores. In a departure from prior work the particle treatments were started concurrent with chloride extraction in order to determine if particle delivery would inhibit chloride transport. Following treatment the specimens were immersed in seawater for 4 weeks. After this posttreatment exposure, the specimens were tested for tensile strength and the steel reinforcement was examined for evidence of corrosion. Scanning electron microscopy was conducted to assess impact on microstructure.

  13. Highly sensitive detection of five typical fluoroquinolones in low-fat milk by field-enhanced sample injection-based CE in bubble cell capillary.

    Science.gov (United States)

    Deng, Yan; Gasilova, Natalia; Qiao, Liang; Zhou, Ying-Lin; Zhang, Xin-Xiang; Girault, Hubert H

    2014-12-01

    Fluoroquinolones are a group of synthetic antibiotics with a broad activity spectrum against mycoplasma, Gram-positive, and Gram-negative bacteria. Due to the extensive use of fluoroquinolones in farming and veterinary science, there is a constant need in the analytical methods able to efficiently monitor their residues in food products of animal origin, regulated by Commission Regulation (European Union) no. 37/2010. Herein, field-enhanced sample injection for sample stacking prior the CZE separation was developed inside a bubble cell capillary for highly sensitive detection of five typical fluoroquinolones in bovine milk. Ethylenediamine was proposed as the main component of BGE for the antibiotics separation. The effect of BGE composition, injection parameters, and water plug length on the field-enhanced sample injection-based CE with UV detection was investigated. Under the optimized conditions, described field-enhanced sample injection-based CE-UV analysis of fluoroquinolones provides LODs varying from 0.4 to 1.3 ng/mL. These LOD values are much lower (from 460 to 1500 times) than those obtained by a conventional CE in a standard capillary without bubble cell. The developed method was finally applied for the analysis of fluoroquinolones in low-fat milk from a Swiss supermarket. Sample recovery values from 93.6 to 106.0% for different fluoroquinolones, and LODs from 0.7 to 2.5 μg/kg, were achieved. Moreover, the proposed ethylenediamine-based BGE as volatile and compatible with MS system, enabled the coupling of the field-enhanced sample injection-based CE with a recently introduced electrostatic spray ionization MS via an iontophoretic fraction collection interface for qualitative fluoroquinolones identification. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Evolving test-fields in a black-hole geometry

    CERN Document Server

    Andersson, N

    1997-01-01

    We consider the initial value problem for a massless scalar field in the Schwarzschild geometry. When constructed using a complex-frequency approach the necessary Green's function splits into three components. We discuss all of these in some detail: 1) The contribution from the singularities (the quasinormal modes of the black hole) is approximated and the mode-sum is demonstrated to converge after a certain well defined time in the evolution. A dynamic description of the mode-excitation is introduced and tested. 2) It is shown how a straightforward low-frequency approximation to the integral along the branch cut in the black-hole Green's function leads to the anticipated power-law fall off at very late times. We also calculate higher order corrections to this tail and show that they provide an important complement to the leading order. 3) The high-frequency problem is also considered. We demonstrate that the combination of the obtained approximations for the quasinormal modes and the power-law tail provide a...

  15. Evolving test fields in a black-hole geometry

    Science.gov (United States)

    Andersson, Nils

    1997-01-01

    We consider the initial value problem for a massless scalar field in the Schwarzschild geometry. When constructed using a complex-frequency approach the necessary Green's function splits into three components. We discuss all of these in some detail. (1) The contribution from the singularities (the quasinormal modes of the black hole) is approximated and the mode sum is demonstrated to converge after a certain well-defined time in the evolution. A dynamic description of the mode excitation is introduced and tested. (2) It is shown how a straightforward low-frequency approximation to the integral along the branch cut in the black-hole Green's function leads to the anticipated power-law falloff at very late times. We also calculate higher order corrections to this tail and show that they provide an important complement to the leading order. (3) The high-frequency problem is also considered. We demonstrate that the combination of the obtained approximations for the quasinormal modes and the power-law tail provide a complete description of the evolution at late times. Problems that arise (in the complex-frequency picture) for early times are also discussed, as is the fact that many of the presented results generalize to, for example, Kerr black holes.

  16. A Field Test of the New Portable Gamma Spectrometry System

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Jung-Ki; Park, Uk Ryang; Park, Seunghoon; Chung, Heejun; Kwak, Sung-Woo [Korea Institute of Nuclear Non-proliferation and Control, Daejeon (Korea, Republic of); Kim, Yongkwn [NuCare Medical Systems, Inc., Incheon (Korea, Republic of)

    2015-10-15

    In order to perform a field test of the system, the measurement of U-235 enrichment for nuclear fuel pellets was conducted along with the IAEA Physical Inventory Verification (PIV) inspection at the KEPCO Nuclear Fuel (KNF). The enrichment value of U-235 was calculated based on the total counts of the 185.7 keV photopeak and compared with the reference line, drawn by certified sources. The goal of this study is to experimentally evaluate the system performance of the developed system. In this study, the new portable gamma spectrometry system showed a good linearity (R{sup 2}=1) but overestimated the enrichment values than IAEA inspection device. It could be caused by the stability of the new system since it found, right after this measurement, that the accuracy of the system gradually increases and becomes stable over time. Further steps will optimize the design parameter based on these results and repeat measurement with the same samples under the same environment.

  17. Field test of a post-closure radiation monitor

    Energy Technology Data Exchange (ETDEWEB)

    Reed, S.E. [Babcock & Wilcox, Alliance, OH (United States); Christy, C.E. [Department of Energy, Morgantown, WV (United States); Heath, R.E. [FERMCO, Cincinnati, OH (United States)

    1995-10-01

    The DOE is conducting remedial actions at many sites contaminated with radioactive materials. After closure of these sites, long-term subsurface monitoring is typically required by law. This monitoring is generally labor intensive and expensive using conventional sampling and analysis techniques. The U.S. Department of Energy`s Morgantown Energy Technology Center (METC) has contracted with Babcock and Wilcox to develop a Long-Term Post-Closure Radiation Monitoring System (LPRMS) to reduce these monitoring costs. The system designed in Phase I of this development program monitors gamma radiation using a subsurface cesium iodide scintillator coupled to above-ground detection electronics using optical waveguide. The radiation probe can be installed to depths up to 50 meters using cone penetrometer techniques, and requires no downhole electrical power. Multiplexing, data logging and analysis are performed at a central location. A prototype LPRMS probe was built, and B&W and FERMCO field tested this monitoring probe at the Fernald Environmental Management Project in the fall of 1994 with funding from the DOE`s Office of Technology Development (EM-50) through METC. The system was used measure soil and water with known uranium contamination levels, both in drums and in situ depths up to 3 meters. For comparison purposes measurements were also performed using a more conventional survey probe with a sodium iodide scintillator directly butt-coupled to detection electronics.

  18. Field test of thermoelectric generating system at Komatsu plant

    Energy Technology Data Exchange (ETDEWEB)

    Kaibe, Hiromasa T.; Fujimoto, Sinichi; Mizukami, Hiroyuki; Morimoto, Shigeo [Komatsu Ltd., Kanagawa (Japan)

    2011-07-01

    At the end of October 2009, Komatsu Ltd. started a field test of the thermoelectric generation (TEG) system at a carburizing facility of Awazu plant. Residual carburizing gas based on such as CO, N and H{sub 2} is burned resulting that 20-30 kW range of flame constantly heats up the hot side of TEG. 16 of the Bi-Te thermo-modules, which were separated into 4 groups, were employed, each of which has a size of 50 by 50 by 4.2 mm{sup 3} and can generate better than 25 W under the circumstance of 280 C and 30 C of hot side and cold side temperature, respectively. Each module has a single booster-type DC/DC converter controlled by one chip computer and Maximum Power point Tracking (MPPT) was well facilitated to search for the maximum output power depending on the hot and cold side temperature. The electric output power from the four modules is summed up to charge a single lead storage battery (GS Yuasa Corp. 12V-65Ah) and then through a DC/AC inverter electricity goes to fluorescent light tubes inside the factory. Typically from 4 groups 200 W can be generated and 170 W is delivered to the batteries. (orig.)

  19. Rigorously testing multialternative decision field theory against random utility models.

    Science.gov (United States)

    Berkowitsch, Nicolas A J; Scheibehenne, Benjamin; Rieskamp, Jörg

    2014-06-01

    Cognitive models of decision making aim to explain the process underlying observed choices. Here, we test a sequential sampling model of decision making, multialternative decision field theory (MDFT; Roe, Busemeyer, & Townsend, 2001), on empirical grounds and compare it against 2 established random utility models of choice: the probit and the logit model. Using a within-subject experimental design, participants in 2 studies repeatedly choose among sets of options (consumer products) described on several attributes. The results of Study 1 showed that all models predicted participants' choices equally well. In Study 2, in which the choice sets were explicitly designed to distinguish the models, MDFT had an advantage in predicting the observed choices. Study 2 further revealed the occurrence of multiple context effects within single participants, indicating an interdependent evaluation of choice options and correlations between different context effects. In sum, the results indicate that sequential sampling models can provide relevant insights into the cognitive process underlying preferential choices and thus can lead to better choice predictions.

  20. The Savannah River Technology Center environmental monitoring field test platform

    Energy Technology Data Exchange (ETDEWEB)

    Rossabi, J.

    1993-03-05

    Nearly all industrial facilities have been responsible for introducing synthetic chemicals into the environment. The Savannah River Site is no exception. Several areas at the site have been contaminated by chlorinated volatile organic chemicals. Because of the persistence and refractory nature of these contaminants, a complete clean up of the site will take many years. A major focus of the mission of the Environmental Sciences Section of the Savannah River Technology Center is to develop better, faster, and less expensive methods for characterizing, monitoring, and remediating the subsurface. These new methods can then be applied directly at the Savannah River Site and at other contaminated areas in the United States and throughout the world. The Environmental Sciences Section has hosted field testing of many different monitoring technologies over the past two years primarily as a result of the Integrated Demonstration Program sponsored by the Department of Energy`s Office of Technology Development. This paper provides an overview of some of the technologies that have been demonstrated at the site and briefly discusses the applicability of these techniques.

  1. Increase in extractable oil reserves through injection of steam and hot water in the Kelebiya Yug oil field

    Energy Technology Data Exchange (ETDEWEB)

    Gobos, Z.; Csizmazia, P.; Kuhn, T.; Voll, L.

    1984-01-01

    A plan is described for injecting steam and hot water, its method, technology of working, surface technological equipment and an analysis is made of the economicalness of the process from the viewpoint of the national economy.

  2. Development of a 3D CFD model for velocity and concentration field of a jet flow in CANDU-6 moderator tank induced by high velocity injection of liquid neutron poison

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Bo Wook; Choi, Hang Bok [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Yun, Hye Jeong [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    2005-05-15

    This report describes the development and validation work of developing a 3D CFD model for analyzing the liquid poison jet velocity and concentration which is necessary for the performance test of SDS2 of CANDU-6 among the forseeable problems expected in the CANDU-6 loaded with DUPIC fuel. As a boundary condition the liquid poison injection rate through each injection hole was given and the 3D CFD model for analyzing the downstream flow and concentration field is developed and validated. The injection rate is calculated by the ALITRIG code developed by AECL. As the ratio of the calandria tank and the injection hole drilled at the injection nozzle is as big as 2000, the grid generation for the calandria is very difficult as the number of the grid can easily exceed the computational load limit of the available work station. Thus to overcome this difficulty the inlet jet flow has been modeled as a source term of the mass, momentum and concentration at the grid near the real inlet. This modeling method enabled the analysis of the jet velocity and concentration possible within the computation limit of the available work station. And as the experimental data available for validating this model has only video taped pictures, and the jet height growth rate is estimated by the observer's subjective judgement, it was most difficult to convert the location of the jet front to the corresponding concentration value. Utilizing the experiment data from Bhabha Atomic Research Center in India, the jet growth rate was validated and the result was very much encouraging. Based on the results the 3D CFD model developed in this report shows physically reasonable results and will be used for the analysis of SDS2 performance test along with the reactor physics codes.

  3. Corrective Action Investigation Plan for Corrective Action Unit 219: Septic Systems and Injection Wells, Nevada Test Site, Nevada, Rev. No.: 0

    Energy Technology Data Exchange (ETDEWEB)

    David A. Strand

    2005-01-01

    The Corrective Action Investigation Plan for Corrective Action Unit 219, Septic Systems and Injection Wells, has been developed in accordance with the ''Federal Facility Agreement and Consent Order'' (1996) that was agreed to by the State of Nevada, the U.S. Department of Energy, and the U.S. Department of Defense. The purpose of the investigation is to ensure that adequate data are collected to provide sufficient and reliable information to identify, evaluate, and select technically viable corrective actions. Corrective Action Unit 219 is located in Areas 3, 16, and 23 of the Nevada Test Site, which is 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 219 is comprised of the six Corrective Action Sites (CASs) listed below: (1) 03-11-01, Steam Pipes and Asbestos Tiles; (2) 16-04-01, Septic Tanks (3); (3) 16-04-02, Distribution Box; (4) 16-04-03, Sewer Pipes; (5) 23-20-01, DNA Motor Pool Sewage and Waste System; and (6) 23-20-02, Injection Well. These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation prior to evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document.

  4. Testing the Visual Soil Assessment tool on Estonian farm fields

    Science.gov (United States)

    Reintam, Endla; Are, Mihkel; Selge, Are

    2017-04-01

    Soil quality estimation plays important role in decision making on farm as well on policy level. Sustaining the production ability and good health of the soil the chemical, physical and biological indicators should be taken into account. The system to use soil chemical parameters is usually quite well established in most European counties, including Estonia. However, measuring soil physical properties, such bulk density, porosity, penetration resistance, structural stability ect is time consuming, needs special tools and is highly weather dependent. In that reason these parameters are excluded from controllable quality parameters in policy in Estonia. Within the project "Interactive Soil Quality Assessment in Europe and China for Agricultural Productivity and Environmental Resilience" (iSQAPER) the visual soil assessment (VSA) tool was developed for easy detection of soil quality as well the different soil friendly agricultural management practices (AMP) were detected. The aim of current study was to test the VSA tool on Estonian farm fields under different management practices and compare the results with laboratory measurements. The main focus was set on soil physical parameters. Next to the VSA, the undisturbed soil samples were collected from the depth of 5-10 cm and 25-30 cm. The study revealed that results of a visually assessed soil physical parameters, such a soil structure, soil structural stability, soil porosity, presence of tillage pan, were confirmed by laboratory measurements in most cases. Soil water stable structure measurement on field (on 1 cm2 net in one 1 l box with 4-6 cm air dry clods for 5-10 min) underestimated very well structured soil on grassland and overestimated the structure aggregates stability of compacted soil. The slightly better soil quality was detected under no-tillage compared to ploughed soils. However, the ploughed soil got higher quality points compared with minimum tillage. The slurry application (organic manuring) had

  5. A Field Study on Simulation of CO2 Injection and ECBM Production and Prediction of CO2 Storage Capacity in Unmineable Coal Seam

    Directory of Open Access Journals (Sweden)

    Qin He

    2013-01-01

    Full Text Available CO2 sequestration into a coal seam project was studied and a numerical model was developed in this paper to simulate the primary and secondary coal bed methane production (CBM/ECBM and carbon dioxide (CO2 injection. The key geological and reservoir parameters, which are germane to driving enhanced coal bed methane (ECBM and CO2 sequestration processes, including cleat permeability, cleat porosity, CH4 adsorption time, CO2 adsorption time, CH4 Langmuir isotherm, CO2 Langmuir isotherm, and Palmer and Mansoori parameters, have been analyzed within a reasonable range. The model simulation results showed good matches for both CBM/ECBM production and CO2 injection compared with the field data. The history-matched model was used to estimate the total CO2 sequestration capacity in the field. The model forecast showed that the total CO2 injection capacity in the coal seam could be 22,817 tons, which is in agreement with the initial estimations based on the Langmuir isotherm experiment. Total CO2 injected in the first three years was 2,600 tons, which according to the model has increased methane recovery (due to ECBM by 6,700 scf/d.

  6. Vadose zone transport field study: Detailed test plan for simulated leak tests

    Energy Technology Data Exchange (ETDEWEB)

    AL Ward; GW Gee

    2000-06-23

    Hanford to: identify mechanisms controlling transport processes in soils typical of the hydrogeologic conditions of Hanford's waste disposal sites; reduce uncertainty in conceptual models; develop a detailed and accurate database of hydraulic and transport parameters for validation of three-dimensional numerical models; identify and evaluate advanced, cost-effective characterization methods with the potential to assess changing conditions in the vadose zone, particularly as surrogates of currently undetectable high-risk contaminants. This plan provides details for conducting field tests during FY 2000 to accomplish these objectives. Details of additional testing during FY 2001 and FY 2002 will be developed as part of the work planning process implemented by the Integration Project.

  7. Smart Infrared Inspection System Field Operational Test Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Siekmann, Adam [ORNL; Capps, Gary J [ORNL; Franzese, Oscar [ORNL; Lascurain, Mary Beth [ORNL

    2011-06-01

    The Smart InfraRed Inspection System (SIRIS) is a tool designed to assist inspectors in determining which vehicles passing through the SIRIS system are in need of further inspection by measuring the thermal data from the wheel components. As a vehicle enters the system, infrared cameras on the road measure temperatures of the brakes, tires, and wheel bearings on both wheel ends of commercial motor vehicles (CMVs) in motion. This thermal data is then presented to enforcement personal inside of the inspection station on a user friendly interface. Vehicles that are suspected to have a violation are automatically alerted to the enforcement staff. The main goal of the SIRIS field operational test (FOT) was to collect data to evaluate the performance of the prototype system and determine the viability of such a system being used for commercial motor vehicle enforcement. From March 2010 to September 2010, ORNL facilitated the SIRIS FOT at the Greene County Inspection Station (IS) in Greeneville, Tennessee. During the course of the FOT, 413 CMVs were given a North American Standard (NAS) Level-1 inspection. Of those 413 CMVs, 384 were subjected to a SIRIS screening. A total of 36 (9.38%) of the vehicles were flagged by SIRIS as having one or more thermal issues; with brakes issues making up 33 (91.67%) of those. Of the 36 vehicles flagged as having thermal issues, 31 (86.11%) were found to have a violation and 30 (83.33%) of those vehicles were placed out-of-service (OOS). Overall the enforcement personnel who have used SIRIS for screening purposes have had positive feedback on the potential of SIRIS. With improvements in detection algorithms and stability, the system will be beneficial to the CMV enforcement community and increase overall trooper productivity by accurately identifying a higher percentage of CMVs to be placed OOS with minimal error. No future evaluation of SIRIS has been deemed necessary and specifications for a production system will soon be drafted.

  8. Influence of the magnetic field profile on ITER conductor testing

    NARCIS (Netherlands)

    Nijhuis, A.; Ilyin, Y.; Kate, ten H.H.J.

    2006-01-01

    We performed simulations with the numerical CUDI-CICC code on a typical short ITER (International Thermonuclear Experimental Reactor) conductor test sample of dual leg configuration, as usually tested in the SULTAN test facility, and made a comparison with the new EFDA-Dipole test facility offering

  9. Table 1. Summary of Field Testing and Measurement Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Key performance parameters measured during the field demonstration such as lining thickness, compressive strength, Flexural Strength, Modulus of Elasticity, bond...

  10. Beam injection into RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, W.; Hahn, H.; MacKay, W.W.; Satogata, T.; Tsoupas, N.; Zhang, W.

    1997-07-01

    During the RHIC sextant test in January 1997 beam was injected into a sixth of one of the rings for the first time. The authors describe the injection zone and its bottlenecks. They report on the commissioning of the injection system, on beam based measurements of the kickers and the application program to steer the beam.

  11. Brick Paving Systems in Expeditionary Environments: Field Testing

    Science.gov (United States)

    2012-07-01

    Dynamic Cone Penetrometer (DCP) tests were conducted on each test item as an alternative strength measurement to the in situ CBR tests conducted on the...many passes of the C-17 load before failure. Between 20 and 40 passes, the majority of the bricks in the wheel path began to break or shatter . Figures...American Society for Testing and Materials. 2003. Standard test method for use of the dynamic cone penetrometer in shallow pavement applications

  12. High HIV prevalence, suboptimal HIV testing, and low knowledge of HIV-positive serostatus among injection drug users in St. Petersburg, Russia.

    Science.gov (United States)

    Niccolai, Linda M; Toussova, Olga V; Verevochkin, Sergei V; Barbour, Russell; Heimer, Robert; Kozlov, Andrei P

    2010-08-01

    The purpose of this analysis was to estimate human immunodeficiency virus (HIV) prevalence and testing patterns among injection drug users (IDUs) in St. Petersburg, Russia. HIV prevalence among 387 IDUs in the sample was 50%. Correlates of HIV-positive serostatus included unemployment, recent unsafe injections, and history/current sexually transmitted infection. Seventy-six percent had been HIV tested, but only 22% of those who did not report HIV-positive serostatus had been tested in the past 12 months and received their test result. Correlates of this measure included recent doctor visit and having been in prison or jail among men. Among the 193 HIV-infected participants, 36% were aware of their HIV-positive serostatus. HIV prevalence is high and continuing to increase in this population. Adequate coverage of HIV testing has not been achieved, resulting in poor knowledge of positive serostatus. Efforts are needed to better understand motivating and deterring factors for HIV testing in this setting.

  13. Applications of advanced petroleum production technology and water alternating gas injection for enhanced oil recovery -- Mattoon Oil Field, Illinois. First quarterly technical progress report, 1993

    Energy Technology Data Exchange (ETDEWEB)

    Baroni, M.R.

    1993-05-24

    For work during the first quarter of 1993, American Oil Recovery, Inc. targeted completion of the following specific objectives: Convene meetings of Mattoon Project subcontractors in order to plan and coordinate Project activities. Confirm organizational arrangements and plans for implementation of Mattoon Project. Complete most work on detailed analysis of reservoir geology of productive leases in the Mattoon Project. Identify first Facies Defined Subunit for initial injectivity testing to be commenced near the beginning of the second quarter. Identify additional Facies Defined Subunits for injectivity testing and characterization during the second and third quarters. Award subcontract to the Illinois State Geological Survey and commence work on preparation of a geostatistical model (STRATAMODEL) of more than 100 wells on 1,000 acres within the Mattoon Project Area. Obtain oil samples from wells in the identified Facies Subunit for reservoir rock, fluid, and CO{sub 2} compatibility testing by the Illinois State Geological Survey. Design CO{sub 2} injection pumps and injection monitoring equipment configuration. Obtain bids for required pumps and diesel motor. Accomplishments for this quarter are reported.

  14. Risk of sensitization in healthy adults following repeated administration of rdESAT-6 skin test reagent by the Mantoux injection technique

    DEFF Research Database (Denmark)

    Lillebaek, Troels; Bergstedt, Winnie; Tingskov, Pernille N;

    2009-01-01

    1 open clinical trial was to assess the sensitization risk and safety of repeated administration of rdESAT-6 reagent in 31 healthy adult volunteers. Three groups of volunteers received two fixed doses of 0.1 microg rdESAT-6 28, 56 or 112 days apart, respectively. After the second injection......Limited specificity of the tuberculin skin test incited the development of the intradermal Mycobacterium tuberculosis-specific rdESAT-6 skin test. Animal studies have shown, however, that there is a possible risk of sensitization when repeated injections of rdESAT-6 are given. The aim of this phase...

  15. Highly sensitive detection of five typical fluoroquinolones in low-fat milk by field-enhanced sample injection based CE in bubble cell capillary

    OpenAIRE

    Deng, Yan; Gasilova, Natalia; Qiao, Liang; Zhou, Ying-Lin; Zhang, Xin-Xiang; Girault, Hubert H.

    2014-01-01

    Fluoroquinolones are a group of synthetic antibiotics with a broad activity spectrum against mycoplasma, gram-positive and gram-negative bacteria. Due to the extensive use of fluoroquinolones in farming and veterinary science, there is a constant need in the analytical methods able to efficiently monitor their residues in food products of animal origin, regulated by Commission Regulation (European Union) no. 37/2010. Herein, field-enhanced sample injection for sample stacking prior the CZE se...

  16. Application of ethanol as a geothermal tracer: a field-test in the Los Azufres geothermal field, Michoacan, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Tello Hinojosa, Enrique [Comision Federal de Electricidad, Morelia, Michoacan (Mexico); Pal Verma, Mahendra [Comision Federal de Electricidad, Morelia, Michoacan (Mexico); Suarez Arriaga, Mario C. [Universidad Michoacana de San Nicolas de Hidalgo, Morelia, Michoacan (Mexico); Barrera Conzalez, Victor; Sandoval Medina, Fernando [Comision Federal de Electricidad, Morelia, Michoacan (Mexico)

    2005-12-01

    The thermal decomposition rate of ethanol, rhodamine WT and fluoroscein was determined from laboratory data obtained under conditions of temperature and pressure that simulated a geothermal reservoir. It was found that ethylic alcohol had better thermal stability rhodamine and fluoroscein. Using data obtained from de-ionized water experiments after 168 hours and 200 degree centigrade of temperature, the rhodamine WT and fluoroscein presented a degradation of 99.4% and 99.7%, respectively, while for the ethanol the degradation percentage under the same conditions was only of 44.6%. According to this, ethylic alcohol can be used as a conservative tracer up to about 250 degree centigrade, while rhodamine WT and fluoroscein can be used only at less than 200 degree centigrade, and only where the transit return time is expected to be less than 7 days. Ethanol was used as a conservative tracer in a field test in the southern zone of the Los Azufres geothermal field. The highest concentration was detected in a monitoring well in the steam phase 15 days after the injection, and in the liquid phase, or brine, 34 days after the injection. This suggests that alcohol fractionates preferentially in the steam phase and moves or migrates twice as fast than it does in the liquid phase. The tracer speed can be calculated in 176 m/day in the steam phase and 77.5 m/day in the brine. The ethanol presents good enough characteristics to be used as a tracer in both phases in geothermal environments. [Spanish] Se determino la velocidad de descomposicion termica del etanol, la rodamina y la fluoresceina a partir de datos de laboratorio obtenidos bajo condiciones de presion y de temperatura que simulan las de un yacimiento geotermico. Se encontro que el alcohol etilico presenta una mayor estabilidad termica que la rodamina y la fluoresceina. Empleando los datos obtenidos de experimentos con agua de-ionizada despues de 168 horas y a 200 grados centigrados de temperatura, la rodamina y la

  17. A study of steam injection in fractured media

    Energy Technology Data Exchange (ETDEWEB)

    Dindoruk, M.D.S.; Aziz, K.; Brigham, W.; Castanier, L.

    1996-02-01

    Steam injection is the most widely used thermal recovery technique for unfractured reservoirs containing heavy oil. There have been numerous studies on theoretical and experimental aspects of steam injection for such systems. Fractured reservoirs contain a large fraction of the world supply of oil, and field tests indicate that steam injection is feasible for such reservoirs. Unfortunately there has been little laboratory work done on steam injection in such systems. The experimental system in this work was designed to understand the mechanisms involved in the transfer of fluids and heat between matrix rocks and fractures under steam injection.

  18. High-resolution cross-borehole thermal tracer testing in granite: preliminary field results

    Science.gov (United States)

    Brixel, Bernard; Klepikova, Maria; Jalali, Mohammadreza; Amann, Florian; Loew, Simon

    2017-04-01

    Understanding how heat is transported, stored and exchanged across fractured media is becoming increasingly relevant in our society, as manifested from the growing popularity of modern technologies relying on the subsurface to either source or store heat. One good example is the utilization of heat from deep hydrothermal or petrothermal systems to generate electricity for base load power generation, a technology also known as deep geothermal energy (DGE). While very attractive in principle, the number of geothermal fields producing economical levels of electricity to this day is still very limited - largely due to the difficulty of either locating deep reservoirs that are both sufficiently hot and permeable or, in the absence of the latter, creating them. In this context, the Swiss Competence Center for Energy Research - Supply of Electricity (SCCER - SoE) is carrying out an in situ stimulation and circulation (ISC) experiment at the Grimsel Test Site (GTS), an underground rock lab located in the Aar massif, in the Swiss Alps. The circulation experiment planned for the post-stimulation phase represents one of the key components of this experimental research program, and the outcome of this test is expected to ultimately provide key insights in the factors controlling the performance of enhanced geothermal reservoirs. Therefore, to support the design of this experiment, short-term thermal tracer tests (TTT) were conducted with the objective to (i) assess the feasibility of conducting TTTs in a relatively intact granite (where fluid flow is controlled by a limited number of discrete fractures); (ii) determine optimal experimental setups; and to ultimately (iii) monitor thermal breakthroughs at high spatial and temporal resolution, providing insights on heat transport and complementing the characterization of hydrogeological conditions carried out through conventional means (e.g. hydraulic and/or solute tracer tests). Presented herein are the results of a 10-day

  19. [Test Reviews in Child Psychology: Test Users Wish to Obtain Practical Information Relevant to their Respective Field of Work].

    Science.gov (United States)

    Renner, Gerolf; Irblich, Dieter

    2016-11-01

    Test Reviews in Child Psychology: Test Users Wish to Obtain Practical Information Relevant to their Respective Field of Work This study investigated to what extent diagnosticians use reviews of psychometric tests for children and adolescents, how they evaluate their quality, and what they expect concerning content. Test users (n = 323) from different areas of work (notably social pediatrics, early intervention, special education, speech and language therapy) rated test reviews as one of the most important sources of information. Readers of test reviews value practically oriented descriptions and evaluations of tests that are relevant to their respective field of work. They expect independent reviews that critically discuss opportunities and limits of the tests under scrutiny. The results show that authors of test reviews should not only have a background in test theory but should also be familiar with the practical application of tests in various settings.

  20. Smouldering Remediation (STAR) Technology: Field Pilot Tests and First Full Scale Application

    Science.gov (United States)

    Gerhard, J.; Kinsman, L.; Torero, J. L.

    2015-12-01

    STAR (Self-sustaining Treatment for Active Remediation) is an innovative remediation technology based on the principles of smoldering combustion where the contaminants are the fuel. The self-sustaining aspect means that a single, local ignition event can result in many days of contaminant destruction in situ. Presented research to date has focused on bench scale experiments, numerical modelling and process understanding. Presented here is the maturation of the in situ technology, including three field pilot tests and a full-scale implementation to treat coal tar-impacted soils. The first pilot determined a Radius of Influence (ROI) for a single ignition of approximately eight feet with an average propagation rate of the reaction of approximately one foot per day. TPH concentrations in soils were reduced from 10,000 milligrams per kilogram to a few hundred milligrams per kilogram. The second pilot was conducted in an area of significant void spaces created through the anthropogenic deposition of clay bricks and tiles. The void spaces led to pre-mature termination of the combustion reaction, limiting ROI and the effectiveness of the technology in this setting. The third case study involved the pilot testing, design, and full-scale implementation of STAR at a 37-acre former chemical manufacturing facility. Three phases of pilot testing were conducted within two hydrogeologic units at the site (i.e., surficial fill and deep alluvial sand units). Pilot testing within the fill demonstrated self-sustained coal tar destruction rates in excess of 800 kg/day supported through air injection at a single well. Deep sand unit testing (twenty-five feet below the water table) resulted in the treatment of a targeted six-foot layer of impacted fine sands to a radial distance of approximately twelve feet. These results (and additional parameters) were used to develop a full-scale STAR design consisting of approximately 1500 surficial fill ignition points and 500 deep sand ignition

  1. State and prospects of using equipment for simultaneous-separate production of oil and separate injection of water in the Uzen Field

    Energy Technology Data Exchange (ETDEWEB)

    Orzhanov, T.K.; Teslyuk, E.V.; Dyusenbaev, I.D.

    1967-08-01

    The Uzen Field consists of several producing strata spaced closely together. The most economical way of developing this field is to use multiple completions in both oil-producing and in water-injection wells. In this way the hydrodynamic characteristics of each formation can be harnessed for maximum economic gain. The authors describe and show in schematic drawings several basic multiple completion arrangements. The basic element in each arrangement is a packer, which isolates one stratum from another. The basic operating principle of each multiple completion shown in this article appears to follow conventional principles.

  2. Design, fabrication and test of a pneumatically controlled, renewable, microfluidic bead trapping device for sequential injection analysis applications

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Guocheng; Lu, Donglai; Fu, Zhifeng; Du, Dan; Ozanich, Richard M.; Wang, Wanjun; Lin, Yuehe

    2016-01-01

    This paper describes the design, fabrication, and testing of a pneumatically controlled,renewable, microfluidic device for conducting bead-based assays in an automated sequential injection analysis system. The device used a “brick wall”-like pillar array (pillar size: 20 μm length X 50 μm width X 45 μm height) with 5 μm gaps between the pillars serving as the micro filter. The flow channel where bead trapping occurred is 500 μm wide X 75 μm deep. An elastomeric membrane and an air chamber were located underneath the flow channel. By applying pressure to the air chamber, the membrane is deformed and pushed upward against the filter structure. This effectively traps beads larger than 5 μm and creates a “bed” or micro column of beads that can be perfused and washed with liquid samples and reagents. Upon completion of the assay process, the pressure is released and the beads are flushed out from underneath the filter structure to renew the device. Mouse IgG was used as a model analyte to test the feasibility of using the proposed device for immunoassay applications. Resulting microbeads from an on-chip fluorescent immunoassay were individually examined using flow cytometry. The results show that the fluorescence signal intensity distribution is fairly narrow indicating high chemical reaction uniformity among the beads population. Electrochemical onchip assay was also conducted. A detection limit of 0.1 ng/mL1 ppb was achieved and good device reliability and repeatability were demonstrated. The novel microfluidic-based beadstrapping device thus opens up a new pathway to design micro-bead based biosensor immunoassays for clinical and othervarious applications.

  3. Single-dose Intramuscular-injection Toxicology Test of Water-soluble Carthami-flos and Cervi cornu parvum Pharmacopuncture in a Rat Model

    Directory of Open Access Journals (Sweden)

    Sunju Park

    2015-09-01

    Full Text Available Objectives: The aim of the study is to investigate both the single-dose intramuscular injection toxicity and the approximate lethal dose of water-soluble Carthami-flos and Cervi cornu parvum pharmacopuncture (WCFC in male and female Sprague-Dawley (SD rats. Methods: The study was conducted at Biotoxtech Co. according to the Good Laboratory Practice (GLP regulation and the toxicity test guidelines of the Ministry of Food and Drug Safety (MFDS after approval of the Institutional Animal Care and Use Committee. Dosages for the control, high dose, middle dose and low dose groups were 0.5 mL/animal of saline and 0.5, 0.25 and 0.125 mL/animal of WCFC, respectively. WCFC was injected into the muscle of the left femoral region by using a disposable syringe (1 mL, 26 gauge. The general symptoms and mortality were observed 30 minutes, 1, 2, 4, and 6 hours after the first injection and then daily for 14 days after the injection. The body weights of the SD rats were measured on the day of the injection (before injection and on the third, seventh, and fourteenth days after the injection. Serum biochemical and hematologic tests, necropsy examinations, and histopathologic examinations at the injection site were performed after the observation period. Results: No deaths, abnormal clinical symptoms, or significant weight changes were observed in either male or female SD rats in the control or the test (0.125, 0.25, and 0.5 mL/animal groups during the observation period. No significant differences in hematology and serum biochemistry and no macroscopic abnormalities at necropsy were found. No abnormal reactions at injection sites were noted on the topical tolerance tests. Conclusion: The results of this single-dose toxicity study show that WCFC is safe, its lethal doses in male and female SD rats being estimated to be higher than 0.5 mL/animal.

  4. Field test of two high-pressure direct-contact downhole steam generators. Volume II. Oxygen/diesel system

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, J.B.

    1983-07-01

    A field test of an oxygen/diesel fuel, direct contact steam generator has been completed. The field test, which was a part of Project DEEP STEAM and was sponsored by the US Department of Energy, involved the thermal stimulation of a well pattern in the Tar Zone of the Wilmington Oil Field. The activity was carried out in cooperation with the City of Long Beach and the Long Beach Oil Development Company. The steam generator was operated at ground level, with the steam and combustion products delivered to the reservoir through 2022 feet of calcium-silicate insulated tubing. The objectives of the test included demonstrations of safety, operational ease, reliability and lifetime; investigations of reservoir response, environmental impact, and economics; and comparison of those points with a second generator that used air rather than oxygen. The test was extensively instrumented to provide the required data. Excluding interruptions not attributable to the oxygen/diesel system, steam was injected 78% of the time. System lifetime was limited by the combustor, which required some parts replacement every 2 to 3 weeks. For the conditions of this particular test, the use of trucked-in LOX resulted in liess expense than did the production of the equivalent amount of high pressure air using on site compressors. No statistically significant production change in the eight-acre oxygen system well pattern occurred during the test, nor were any adverse effects on the reservoir character detected. Gas analyses during the field test showed very low levels of SOX (less than or equal to 1 ppM) in the generator gaseous effluent. The SOX and NOX data did not permit any conclusion to be drawn regarding reservoir scrubbing. Appreciable levels of CO (less than or equal to 5%) were measured at the generator, and in this case produced-gas analyses showed evidence of significant gas scrubbing. 64 figures, 10 tables.

  5. TESTING GALACTIC MAGNETIC FIELD MODELS USING NEAR-INFRARED POLARIMETRY

    Energy Technology Data Exchange (ETDEWEB)

    Pavel, Michael D.; Clemens, D. P.; Pinnick, A. F., E-mail: pavelmi@bu.edu, E-mail: clemens@bu.edu, E-mail: apinnick@bu.edu [Institute for Astrophysical Research Boston University, 725 Commonwealth Ave, Boston, MA 02215 (United States)

    2012-04-10

    This work combines new observations of NIR starlight linear polarimetry with previously simulated observations in order to constrain dynamo models of the Galactic magnetic field. Polarimetric observations were obtained with the Mimir instrument on the Perkins Telescope in Flagstaff, AZ, along a line of constant Galactic longitude (l = 150 Degree-Sign ) with 17 pointings of the 10' Multiplication-Sign 10' field of view between -75 Degree-Sign < b < 10 Degree-Sign , with more frequent pointings toward the Galactic midplane. A total of 10,962 stars were photometrically measured and 1116 had usable polarizations. The observed distribution of polarization position angles with Galactic latitude and the cumulative distribution function of the measured polarizations are compared to predicted values. While the predictions lack the effects of turbulence and are therefore idealized, this comparison allows significant rejection of A0-type magnetic field models. S0 and disk-even halo-odd magnetic field geometries are also rejected by the observations, but at lower significance. New predictions of spiral-type, axisymmetric magnetic fields, when combined with these new NIR observations, constrain the Galactic magnetic field spiral pitch angle to -6 Degree-Sign {+-} 2 Degree-Sign .

  6. Medroxyprogesterone Injection

    Science.gov (United States)

    Medroxyprogesterone intramuscular (into a muscle) injection and medroxyprogesterone subcutaneous (under the skin) injection are used to prevent pregnancy. Medroxyprogesterone subcutaneous injection is also used to treat endometriosis (a condition in which ...

  7. Pentamidine Injection

    Science.gov (United States)

    Pentamidine injection is used to treat pneumonia caused by a fungus called Pneumocystis carinii. It is in ... Pentamidine injection comes as powder to be mixed with liquid to be injected intramuscularly (into a muscle) ...

  8. 78 FR 29698 - Availability of an Environmental Assessment for Field Testing a Canine Lymphoma Vaccine, DNA

    Science.gov (United States)

    2013-05-21

    ... Service has prepared an environmental assessment concerning authorization to ship for the purpose of field testing, and then to field test, an unlicensed Canine Lymphoma Vaccine, DNA. The environmental assessment... Animal and Plant Health Inspection Service Availability of an Environmental Assessment for Field...

  9. 2PSD110X型单体泵试验台设计%Test bench design of 2PSD110X individual fuel injection pump test bench

    Institute of Scientific and Technical Information of China (English)

    戴俊; 张士强

    2012-01-01

    随着柴油机应用的日益广泛,喷油泵的调整试验工作日益被人们所重视.2PSD110X型单体泵试验台是适应单体泵技术发展要求而研制成的.2PSD110X型单体泵试验台主要由嵌入式CPU工作站、变频调速系统、机械传动系统、燃油供应系统、压缩机冷却系统、喷油量计量系统及辅助装置等组成.操作及控制部分采用先进的微电软、硬件技术,量油装置采用新型的质量式量油装置,大幅提高了燃油量测量的准确性.%Along with diesel engine application day by day widespread,injection pump' s tune-up test work is taken day by day by the people. The 2PSD110X monomer pump test platform adapts the monomer pump technological development request. The 2PSD110X monomer pump test platform mainly is composed by the embedded CPU workstation, the frequency conversion velocity modulation system, the mechanical drive system, the fuel supply system, the compressor cooling system, the distributive value measuring system and the auxiliary unit and so on. The operation and the control section use the advanced micro electricity soft and hard technology, the measureing oil installment uses the new quality formula weight oil installment, enhanced the fuel hold-up survey accuracy largely.

  10. Field Lysimeter Test Facility: Protective barrier test results (FY 1990, the third year)

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, M.D.; Gee, G.W.

    1990-11-01

    The Field Lysimeter Test Facility (FLTF) was constructed to test protective barriers for isolating low-level radioactive and hazardous wastes from the biosphere. Protective barriers are specially configured earth materials placed over near-surface wastes to prevent intrusion of water, plants, and animals. Low-level radioactive waste is stored in near-surface repositories at the Hanford Site and can be transported into the biosphere by water, plants, and animals. The purpose of the FLTF is to measure water balance within barriers as precipitation is partitioned to evaporation (including transpiration), storage, and drainage. Runoff was prevented by raised edges on the lysimeters. Water balance in protective barriers depends on the water-holding capacity of the soil, the gradient of a potential, and the conductivity of the underlying capillary barrier. Current barrier design uses soil with a high water storage capacity and a capillary barrier underlying the soil to increase its water storage capacity. This increased storage capacity is to hold water, which would normally drain, near the the surface where evaporation can cycle it back to the atmosphere. 7 refs., 23 figs., 5 tabs.

  11. Corrective Action Decision Document for Corrective Action Unit 322: Areas 1 and 3 Release Sites and Injection Wells Nevada Test Site, Nevada, Revision 0 with ROTC 1

    Energy Technology Data Exchange (ETDEWEB)

    Boehlecke, Robert

    2004-12-01

    This Corrective Action Decision Document has been prepared for Corrective Action Unit (CAU) 322, Areas 1 and 3 Release Sites and Injection Wells, Nevada Test Site, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (1996). Corrective Action Unit 322 is comprised of the following corrective action sites (CASs): (1) 01-25-01 - AST Release Site; (2) 03-25-03 - Mud Plant and AST Diesel Release; and (3) 03-20-05 - Injection Wells and BOP Shop. The purpose of this Corrective Action Decision Document is to identify and provide the rationale for the recommendation of a corrective action alternative for each CAS within CAU 322. Corrective action investigation activities were performed from April 2004 through September 2004, as set forth in the Corrective Action Investigation Plan. The purposes of the activities as defined during the data quality objectives process were: (1) Determine if contaminants of concern (COCs) are present; (2) If COCs are present, determine their nature and extent; and (3) Provide sufficient information and data to recommend appropriate corrective actions for the CASs. Analytes detected during the corrective action investigation were evaluated against appropriate preliminary action levels to identify contaminants of concern for each corrective action site. Radiological field measurements were compared to unrestricted release criteria. Assessment of the data generated from investigation activities revealed the following: (1) CAS 01-25-01 contains an AST berm contaminated with total petroleum hydrocarbons (TPH) diesel-range organics (DRO). (2) CAS 03-25-03 includes two distinct areas: Area A where no contamination remains from a potential spill associated with an AST, and Area B where TPH-DRO contamination associated with various activities at the mud plant was identified. The Area B contamination was found at various locations and depths. (3) CAS 03-25-03 Area B contains TPH-DRO contamination at various

  12. Preimplantation genetic screening as an alternative to prenatal testing for Down syndrome : preferences of women undergoing in vitro fertilization/intracytoplasmic sperm injection treatment

    NARCIS (Netherlands)

    Twisk, Moniek; Haadsma, Maaike L.; van der Veen, Fulco; Repping, Sjoerd; Mastenbroek, Sebastiaan; Heineman, Maas-Jan; Bossuyt, Patrick M. M.; Korevaar, Johanna C.

    2007-01-01

    Objective: Although the primary goal of preimplantation genetic screening (PGS) is to increase pregnancy rates in women undergoing IVF/intracytoplasmic sperm injection treatment, it has been suggested that it may also be used as an alternative to prenatal testing for Down syndrome. Design: Trade-off

  13. Transport and attenuation of carboxylate-modified latex microspheres in fractured rock laboratory and field tracer tests

    Science.gov (United States)

    Becker, M.W.; Reimus, P.W.; Vilks, P.

    1999-01-01

    Understanding colloid transport in ground water is essential to assessing the migration of colloid-size contaminants, the facilitation of dissolved contaminant transport by colloids, in situ bioremediation, and the health risks of pathogen contamination in drinking water wells. Much has been learned through laboratory and field-scale colloid tracer tests, but progress has been hampered by a lack of consistent tracer testing methodology at different scales and fluid velocities. This paper presents laboratory and field tracer tests in fractured rock that use the same type of colloid tracer over an almost three orders-of-magnitude range in scale and fluid velocity. Fluorescently-dyed carboxylate-modified latex (CML) microspheres (0.19 to 0.98 ??m diameter) were used as tracers in (1) a naturally fractured tuff sample, (2) a large block of naturally fractured granite, (3) a fractured granite field site, and (4) another fractured granite/schist field site. In all cases, the mean transport time of the microspheres was shorter than the solutes, regardless of detection limit. In all but the smallest scale test, only a fraction of the injected microsphere mass was recovered, with the smaller microspheres being recovered to a greater extent than the larger microspheres. Using existing theory, we hypothesize that the observed microsphere early arrival was due to volume exclusion and attenuation was due to aggregation and/or settling during transport. In most tests, microspheres were detected using flow cytometry, which proved to be an excellent method of analysis. CML microspheres appear to be useful tracers for fractured rock in forced gradient and short-term natural gradient tests, but longer residence times may result in small microsphere recoveries.Understanding colloid transport in ground water is essential to assessing the migration of colloid-size contaminants, the facilitation of dissolved contaminant transport by colloids, in situ bioremediation, and the health risks

  14. A novel capillary electrophoresis method with pressure assisted field amplified sample injection in determination of thiol collectors in flotation process waters.

    Science.gov (United States)

    Sihvonen, T; Aaltonen, A; Leppinen, J; Hiltunen, S; Sirén, H

    2014-01-17

    A new capillary electrophoresis method was developed for the quantification of diisobutyldithiophosphate (DTP), diisobutyldithiophosphinate (DTPI) and ethyl and isobutyl xanthates (EX, IBX) all of which are used as thiol collectors in froth flotation. This method uses pressure assisted field amplified sample injection (PA-FASI) to concentrate the analytes at the capillary inlet. The background electrolyte in electrophoretic separation was 60millimolar (mM) from 3-(cyclohexylamino)propane-1-sulfonic acid (CAPS) in 40mM NaOH solution. The similar CAPS electrolyte solution has earlier been used for screening for diuretics that contained sulphonamide and/or carboxylic groups. In this study, the functional groups are xanthate, phosphate and phosphinate. The method was developed using actual flotation process waters. The results showed that the water delivered from the plant did not contain significant amount of collectors; therefore, method development was accomplished by spiking analytes in these waters. Separation of analytes was achieved in 15min. The range of quantification was 0.27-66.6mg/L (R(2) 0.9991-0.9999) for all analytes other than ethyl xanthate, for which the range was 0.09-66.6mg/L (R(2) 0.9999). LOD (S/N=3) and LOQ (S/N=10) values for DTP, DTPI, IBX and EX were 0.05, 0.07, 0.06 and 0.01mg/L and 0.16, 0.25, 0.21 and 0.04mg/L, respectively. No interference from the matrices was observed, when the method was tested at a gold concentrator plant.

  15. Testing Chameleon Theories with Light Propagating through a Magnetic Field

    CERN Document Server

    Brax, P; Davis, A C; Mota, D F; Shaw, D J

    2007-01-01

    It was recently argued that the observed PVLAS anomaly can be explained by chameleon field theories in which large deviations from Newton's law can be avoided. Here we present the predictions for the dichroism and the birefringence induced in the vacuum by a magnetic field in these models. We show that chameleon particles behave very differently from standard axion-like particles (ALPs). We find that, unlike ALPs, the chameleon particles are confined within the experimental set-up. As a consequence, the birefringence is always bigger than the dichroism in PVLAS-type experiments.

  16. A semi-field approach to testing effects of fresh pesticide residues on bees in multiple-rate test

    NARCIS (Netherlands)

    Bakker, F.; Calis, J.N.M.

    2003-01-01

    We describe a semi-field cage test specifically designed to test effects of delayed exposure to plant protection products. The trial involved the use of standardised mini-beehives. The principle of the trial was to prepare two groups of potted test plants per treatment. The first group of plants rem

  17. Advective Heat Transport in an Unconfined Aquifer Induced by the Field Injection of an Open-Loop Groundwater Heat Pump

    Directory of Open Access Journals (Sweden)

    Stefano L. Russo

    2010-01-01

    Full Text Available Problem statement: The increasing diffusion of low-enthalpy geothermal open-loop Groundwater Heat Pumps (GWHP providing buildings air conditioning requires a careful assessment of the overall effects on groundwater system, especially in the urban areas. The impact on the groundwater temperature in the surrounding area of the re-injection well is directly linked to the aquifer properties. Physical processes affecting heat transport within an aquifer include advection (or convection and hydrodynamic thermodispersion (diffusion and mechanical dispersion. If the groundwater flows, the advective components tend to dominate the heat transfer process within the aquifer and the diffusion can be considered negligible. This study illustrates the experimental results derived from the groundwater monitoring in the surrounding area of an injection well connected to an open-loop GWHP plant which has been installed in the "Politecnico di Torino" (NW Italy for cooling some of the university buildings. Groundwater pumping and injection interfere only with the upper unconfined aquifer. Approach: After the description of the hydrogeological setting the authors examined the data deriving from multiparameter probes installed inside the pumping well (P2, the injection well (P4 and a downgradient piezometer (S2. Data refers to the summer 2009. To control the aquifer thermal stratification some multi-temporal temperature logs have been performed in the S2. Results: After the injection of warm water in P4 the plume arrived after 30 days in the S2. That delay is compatible with the calculated plume migration velocity (1.27 m d-1 and their respective distance (35 m. The natural temperature in the aquifer due to the switching-off of the GWHP plant has been reached after two month. The Electrical Conductivity (EC values tend to vary out of phase with the temperature. The temperature logs in the S2 highlighted a thermal stratification in the aquifer due to a low vertical

  18. CO2 Storage and Enhanced Oil Recovery: Bald Unit Test Site, Mumford Hills Oil Field, Posey County, Indiana

    Energy Technology Data Exchange (ETDEWEB)

    Frailey, Scott M. [Illinois State Geological Survey, Champaign, IL (United States); Krapac, Ivan G. [Illinois State Geological Survey, Champaign, IL (United States); Damico, James R. [Illinois State Geological Survey, Champaign, IL (United States); Okwen, Roland T. [Illinois State Geological Survey, Champaign, IL (United States); McKaskle, Ray W. [Illinois State Geological Survey, Champaign, IL (United States)

    2012-03-30

    The Midwest Geological Sequestration Consortium (MGSC) carried out a small-scale carbon dioxide (CO2) injection test in a sandstone within the Clore Formation (Mississippian System, Chesterian Series) in order to gauge the large-scale CO2 storage that might be realized from enhanced oil recovery (EOR) of mature Illinois Basin oil fields via miscible liquid CO2 flooding.

  19. Laboratory and Field Tests of Ultrasonic Sensors for Precision Sprayers

    Science.gov (United States)

    Reliable function of sensors under rough field conditions is required for the development of variable-rate sprayers to deliver pest control agents to tree liners in ornamental nurseries. Two ultrasonic sensors were examined to identify how their durability and detection stability would be influenced...

  20. Translating laboratory compaction test results to field scale

    NARCIS (Netherlands)

    Roholl, J.A.; Thienen-Visser, K. van; Breunese, J.N.

    2016-01-01

    In recent studies on the surface subsidence caused by hydrocarbon recovery of the Groningen gas field, the predicted subsidence is overestimated if results of compaction experiments are not corrected by an empirical `upscaling factor'. In order to find an explanation for this `upscaling factor', an

  1. Test of Scintillometer Saturation Correction Methods Using Field Experimental Data

    NARCIS (Netherlands)

    Kleissl, J.; Hartogensis, O.K.; Gomez, J.D.

    2010-01-01

    Saturation of large aperture scintillometer (LAS) signals can result in sensible heat flux measurements that are biased low. A field study with LASs of different aperture sizes and path lengths was performed to investigate the onset of, and corrections for, signal saturation. Saturation already occu

  2. Consensus on Intermediate Scale Salt Field Test Design

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlman, Kristopher L; Mills, Melissa Marie; Matteo, Edward N

    2017-03-01

    This report summarizes the first stage in a collaborative effort by Sandia, Los Alamos, and Lawrence Berkeley National Laboratories to design a small-diameter borehole heater test in salt at the Waste Isolation Pilot Plant (WIPP) for the US Department of Energy Office of Nuclear Energy (DOE-NE). The intention is to complete test design during the remainder of fiscal year 2017 (FY17), and the implementation of the test will begin in FY18. This document is the result of regular meetings between the three national labs and the DOE-NE, and is intended to represent a consensus of these meetings and discussions.

  3. Standard Guide for Conducting Corrosion Tests in Field Applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide covers procedures for conducting corrosion tests in plant equipment or systems under operating conditions to evaluate the corrosion resistance of engineering materials. It does not cover electrochemical methods for determining corrosion rates. 1.1.1 While intended primarily for immersion tests, general guidelines provided can be applicable for exposure of test specimens in plant atmospheres, provided that placement and orientation of the test specimens is non-restrictive to air circulation. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See also 10.4.2.

  4. SMART Wind Turbine Rotor: Design and Field Test

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Jonathan C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Resor, Brian R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Paquette, Joshua A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); White, Jonathan R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-01-29

    This report documents the design, fabrication, and testing of the SMART Rotor. This work established hypothetical approaches for integrating active aerodynamic devices (AADs) into the wind turbine structure and controllers.

  5. Magma injection into a long-lived reservoir to explain geodetically measured uplift: Application to the 2007-2014 unrest episode at Laguna del Maule volcanic field, Chile

    Science.gov (United States)

    Le Mével, Hélène; Gregg, Patricia M.; Feigl, Kurt L.

    2016-08-01

    Moving beyond the widely used kinematic models for the deformation sources, we present a new dynamic model to describe the process of injecting magma into an existing magma reservoir. To validate this model, we derive an analytical solution and compare its results to those calculated using the Finite Element Method. A Newtonian fluid characterized by its viscosity, density, and overpressure (relative to the lithostatic value) flows through a vertical conduit, intruding into a reservoir embedded in an elastic domain, leading to an increase in reservoir pressure and time-dependent surface deformation. We apply our injection model to Interferometric Synthetic Aperture Radar (InSAR) data from the ongoing unrest episode at Laguna del Maule (Chile) volcanic field that started in 2007. Using a grid search optimization, we minimize the misfit to the InSAR displacement data and vary the three parameters governing the analytical solution: the characteristic timescale τP for magma propagation, the maximum injection pressure, and the inflection time when the acceleration switches from positive to negative. For a spheroid with semimajor axis a = 6200 m, semiminor axis c = 100 m, located at a depth of 4.5 km in a purely elastic half-space, the best fit to the InSAR displacement data occurs for τP=9.5 years and an injection pressure rising up to 11.5 MPa for 2 years. The volume flow rate increased to 1.2 m3/s for 2 years and then decreased to 0.7 m3/s in 2014. In 7.3 years, at least 187 × 106 m3 of magma was injected.

  6. The effects of engine speed and injection characteristics on the flow field and fuel/air mixing in motored two-stroke diesel engines

    Science.gov (United States)

    Nguyen, H. L.; Carpenter, M. H.; Ramos, J. I.

    1987-01-01

    A numerical analysis is presented on the effects of the engine speed, injection angle, droplet distribution function, and spray cone angle on the flow field, spray penetration and vaporization, and turbulence in a turbocharged motored two-stroke diesel engine. The results indicate that the spray penetration and vaporization, velocity, and turbulence kinetic energy increase with the intake swirl angle. Good spray penetration, vaporization, and mixing can be achieved by injecting droplets of diameters between 50 and 100 microns along a 120-deg cone at about 315 deg before top-dead-center for an intake swirl angle of 30 deg. The spray penetration and vaporization were found to be insensitive to the turbulence levels within the cylinder. The results have also indicated that squish is necessary in order to increase the fuel vaporization rate and mixing.

  7. Unsteady three dimensional flow of Casson liquid film over a porous stretching sheet in the presence of uniform transverse magnetic field and suction/injection

    Energy Technology Data Exchange (ETDEWEB)

    Maity, S., E-mail: susantamaiti@gmail.com [Department of Mathematics, National Institute of Technology, Arunachal Pradesh, Yupia, Papumpare 791112 (India); Singh, S.K. [Engineering Mechanics Unit, Jawaharlal Nehru Centre for Advanced Scientific Research, Bangalore 560064 (India); Kumar, A.V. [Department of Mathematics, National Institute of Technology, Arunachal Pradesh, Yupia, Papumpare 791112 (India)

    2016-12-01

    Three dimensional flow of thin Casson liquid film over a porous unsteady stretching sheet is investigated under assumption of initial uniform film thickness. The effects of the uniform transverse magnetic field, suction and injection are also considered for investigation. The nonlinear governing set of equations and film evolution equation are solved analytically by using singular perturbation technique. It is found that the film thickness decreases with the increasing values of the Casson parameter. The Hartmann number and porosity parameter resist the film thinning process. It is also observed that the film thickness increases with the increasing values of the suction velocity whereas it decreases for increasing values of the injection velocity at the stretching surface.

  8. Unsteady three dimensional flow of Casson liquid film over a porous stretching sheet in the presence of uniform transverse magnetic field and suction/injection

    Science.gov (United States)

    Maity, S.; Singh, S. K.; Kumar, A. V.

    2016-12-01

    Three dimensional flow of thin Casson liquid film over a porous unsteady stretching sheet is investigated under assumption of initial uniform film thickness. The effects of the uniform transverse magnetic field, suction and injection are also considered for investigation. The nonlinear governing set of equations and film evolution equation are solved analytically by using singular perturbation technique. It is found that the film thickness decreases with the increasing values of the Casson parameter. The Hartmann number and porosity parameter resist the film thinning process. It is also observed that the film thickness increases with the increasing values of the suction velocity whereas it decreases for increasing values of the injection velocity at the stretching surface.

  9. Initial field testing definition of subsurface sealing and backfilling tests in unsaturated tuff; Yucca Mountain Site Characterization Project

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, J.A. [Sandia National Labs., Albuquerque, NM (United States); Case, J.B.; Tyburski, J.R. [I. T. Corp., Albuquerque, NM (United States)

    1993-05-01

    This report contains an initial definition of the field tests proposed for the Yucca Mountain Project repository sealing program. The tests are intended to resolve various performance and emplacement concerns. Examples of concerns to be addressed include achieving selected hydrologic and structural requirements for seals, removing portions of the shaft liner, excavating keyways, emplacing cementitious and earthen seals, reducing the impact of fines on the hydraulic conductivity of fractures, efficient grouting of fracture zones, sealing of exploratory boreholes, and controlling the flow of water by using engineered designs. Ten discrete tests are proposed to address these and other concerns. These tests are divided into two groups: Seal component tests and performance confirmation tests. The seal component tests are thorough small-scale in situ tests, the intermediate-scale borehole seal tests, the fracture grouting tests, the surface backfill tests, and the grouted rock mass tests. The seal system tests are the seepage control tests, the backfill tests, the bulkhead test in the Calico Hills unit, the large-scale shaft seal and shaft fill tests, and the remote borehole sealing tests. The tests are proposed to be performed in six discrete areas, including welded and non-welded environments, primarily located outside the potential repository area. The final selection of sealing tests will depend on the nature of the geologic and hydrologic conditions encountered during the development of the Exploratory Studies Facility and detailed numerical analyses. Tests are likely to be performed both before and after License Application.

  10. Field Jet Erosion Tests on the Mississippi River Collocated Demonstration Section, Plaquemines Parish, Louisiana

    Science.gov (United States)

    2015-06-01

    ER D C/ G SL T R- 15 -1 3 Field Jet Erosion Tests on the Mississippi River Collocated Demonstration Section, Plaquemines Parish...default. ERDC/GSL TR-15-13 June 2015 Field Jet Erosion Tests on the Mississippi River Collocated Demonstration Section, Plaquemines Parish...Prepared for U.S. Army Corps of Engineers Washington, DC 20314-1000 ERDC/GSL TR-15-13 ii Abstract Field jet erosion tests (JETs) were

  11. Field testing the prototype BNL fan-atomized oil burner

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, R.; Celebi, Y. [Brookhaven National Lab., Upton, NY (United States)

    1995-04-01

    BNL has developed a new oil burner design referred to as the Fan Atomized burner System. The primary objective of the field study was to evaluate and demonstrate the reliable operation of the Fan Atomized Burner. The secondary objective was to establish and validate the ability of a low firing rate burner (0.3-0.4 gph) to fully satisfy the heating and domestic hot water load demands of an average household in a climate zone with over 5,000 heating-degree-days. The field activity was also used to evaluate the practicality of side-wall venting with the Fan Atomized Burner with a low stack temperature (300F) and illustrate the potential for very high efficiency with an integrated heating system approach based on the Fan Atomized Burner.

  12. Tests and Field Map of LHCb Dipole Magnet

    CERN Document Server

    Losasso, Marcello; Flegel, Wilfried; Giudici, Pierre-Ange; Hernando, Jose Angel; Jamet, Olivier; Lindner, Rolf; Renaud, Jean; Teubert, Frederic

    2005-01-01

    The LHCb experiment at the LHC at CERN is aimed to study CP violation and to measure the rare decays of B-mesons with exceptionally high precision. A 4 Tm dipole magnet is required for particle separation and momentum measurements. The 1600 ton warm magnet with sloping poles was installed and fully commissioned by the end of 2004. It is the first detector magnet of the four LHC experiments to have been aligned and commissioned in its final position. In this paper the magnet installation in the underground cavern of Point 8 and its alignment on the beam line are shortly reviewed. Results of a first magnetic field mapping in the region of the magnet poles and the fringe field in the location of the RICH detectors are presented. The mechanical equipment used for the automatic displacement of the Hall probe array is described together with the precision of the measurements obtained which are compared with TOSCA finite element calculations.

  13. Sound field control for a low-frequency test facility

    DEFF Research Database (Denmark)

    Pedersen, Christian Sejer; Møller, Henrik

    2013-01-01

    The two largest problems in controlling the reproduction of low-frequency sound for psychoacoustic experiments is the effect of the room due to standing waves and the relatively large sound pressure levels needed. Anechoic rooms are limited downward in frequency and distortion may be a problem even...... at moderate levels, while pressure-field playback can give higher sound pressures but is limited upwards in frequency. A new solution that addresses both problems has been implemented in the laboratory of Acoustics, Aalborg University. The solution uses one wall with 20 loudspeakers to generate a plane wave...... that is actively absorbed when it reaches the 20 loudspeakers on the opposing wall. This gives a homogeneous sound field in the majority of the room with a flat frequency response in the frequency range 2-300 Hz. The lowest frequencies are limited to sound pressure levels in the order of 95 dB. If larger levels...

  14. Design and Installation of a Disposal Cell Cover Field Test

    Energy Technology Data Exchange (ETDEWEB)

    Benson, C.H. [University of Wisconsin–Madison, Madison, Wisconsin; Waugh, W.J. [S.M. Stoller Corporation, Grand Junction, Colorado; Albright, W.H. [Desert Research Institute, Reno, Nevada; Smith, G.M. [Geo-Smith Engineering, Grand Junction, Colorado; Bush, R.P. [U.S. Department of Energy, Grand Junction, Colorado

    2011-02-27

    The U.S. Department of Energy’s Office of Legacy Management (LM) initiated a cover assessment project in September 2007 to evaluate an inexpensive approach to enhancing the hydrological performance of final covers for disposal cells. The objective is to accelerate and enhance natural processes that are transforming existing conventional covers, which rely on low-conductivity earthen barriers, into water balance covers, that store water in soil and release it as soil evaporation and plant transpiration. A low conductivity cover could be modified by deliberately blending the upper layers of the cover profile and planting native shrubs. A test facility was constructed at the Grand Junction, Colorado, Disposal Site to evaluate the proposed methodology. The test cover was constructed in two identical sections, each including a large drainage lysimeter. The test cover was constructed with the same design and using the same materials as the existing disposal cell in order to allow for a direct comparison of performance. One test section will be renovated using the proposed method; the other is a control. LM is using the lysimeters to evaluate the effectiveness of the renovation treatment by monitoring hydrologic conditions within the cover profile as well as all water entering and leaving the system. This paper describes the historical experience of final covers employing earthen barrier layers, the design and operation of the lysimeter test facility, testing conducted to characterize the as-built engineering and edaphic properties of the lysimeter soils, the calibration of instruments installed at the test facility, and monitoring data collected since the lysimeters were constructed.

  15. Establishment of Bacterial Endotoxins Test of Xiyanping Injection%喜炎平注射液细菌内毒素检查法的建立

    Institute of Scientific and Technical Information of China (English)

    吴寒寅; 孟德胜

    2012-01-01

    目的 建立喜炎平注射液细菌内毒素检查法.方法 按2010年版《中国药典(二部)》附录细菌内毒素检查法,用不同厂家的鲎试剂对3个批号的喜炎平注射液分别进行干扰试验和细菌内毒素检查.结果 喜炎平注射液稀释到40倍(质量浓度为1.25 g/L)时对细菌内毒素检查法无干扰,细菌内毒素限值L=5 EU/mL,按照拟订标准,3批样品细菌内毒素检查均符合规定.结论 所建立的鲎试剂法可用于喜炎平注射液的细菌内毒素检查.%Objective To establish the method of bacterial endotoxin test of Xiyanping injection. Methods Based on the bacterial endo-toxin test in the appendix of the Chinese Pharmacopeia(edition 2010,part 2),the interference test and the bacterial endotoxin test were conducted on the samples from 3 batches of Xiyanping injection by using tachypleus amebocyte lysate(TAL) from different manufacturers. Results Xiyanping injection solution with dilution to 40 times (mass concentration 1. 25 g/L) had no interference on the bacterial endotoxin test. The limit value of the bacterial endotoxin was 5 EU/mL. According to the established standard, the bacterial endotoxin test in the 3 batches of samples conformed to the stipulation. Conclusion The established TAL method may be applicable for the bacterial endotoxin test of Xiyanping injection.

  16. 肾康注射液细菌内毒素检查法的建立%Establishment of Bacterial Endotoxin Test of Shenkang Injection

    Institute of Scientific and Technical Information of China (English)

    吴寒寅; 孟德胜

    2011-01-01

    Objective To establish the bacterial endotoxin test of Shenkang injection. Methods Based on Chinese Pharmacopeia (edition 2010, Vol Ⅱ), the interference test and bacterial endotoxin test were conducted on 3 batches of Shenkang injection samples using tachypleus amebocyte lysate from different companies. Results 6- fold dilution of Shenkang Injection had no interference to the bacterial endotoxin test. The limit value of the bacterial endotoxin was L=4 EU/mL. According to the established standard, the results of bacterial endotoxin test in 3 batches of samples were conformed to the required stipulation. Conclusion The established bacterial endotoxin test may be applicable for bacterial endotoxin test of Shenkang injection.%目的 建立肾康注射液的细菌内毒素检查法.方法按2010年版附录Ⅱ细菌内毒素检查法,用不同厂家的鲎试剂对3批肾康注射液分别进行干扰试验和细菌内毒素检查.结果肾康注射液稀释6倍时对细菌内毒素检查无干扰,细菌内毒素限值为4EU/mL.按照拟订标准,3批样品的细菌内毒素检查均符合规定.结论所建立的细菌内毒素检查法可用于肾康注射液的细菌内毒素检查.

  17. Biotechnology; Managing the Risks of Field Testing Genetically Engineered Organisms

    Science.gov (United States)

    1988-06-01

    goals are to minimize risk to public health and the environment while support - ing industrial productivity and competitiveness. In addressing the...jil. initegrat ing t ie( resiults at’ risk mssessitieut %Wit Iti (ugi- livering tia~ andu w~ithI social . (iconiri. and l i u atiii irit-ijis toa c...34authorization to ship [an experimental product] for field trials under controlled conditions... for the purpose of gathering additional information in support

  18. Field Testing of Compartmentalization Methods for Multifamily Construction

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States); Lstiburek, J. [Building Science Corporation, Westford, MA (United States)

    2015-03-01

    The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single-family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, driving the need for easier and more effective methods of compartmentalization in multifamily buildings. Builders and practitioners have found that fire-resistance rated wall assemblies are a major source of difficulty in air sealing/compartmentalization, particularly in townhouse construction. This problem is exacerbated when garages are “tucked in” to the units and living space is located over the garages. In this project, Building Science Corporation examined the taping of exterior sheathing details to improve air sealing results in townhouse and multifamily construction, when coupled with a better understanding of air leakage pathways. Current approaches are cumbersome, expensive, time consuming, and ineffective; these details were proposed as a more effective and efficient method. The effectiveness of these air sealing methods was tested with blower door testing, including “nulled” or “guarded” testing (adjacent units run at equal test pressure to null out inter-unit air leakage, or “pressure neutralization”). Pressure diagnostics were used to evaluate unit-to-unit connections and series leakage pathways (i.e., air leakage from exterior, into the fire-resistance rated wall assembly, and to the interior).

  19. Exercise testing in Warmblood sport horses under field conditions

    NARCIS (Netherlands)

    Munsters, Carolien C B M; van Iwaarden, Alexandra; van Weeren, René; Sloet van Oldruitenborgh-Oosterbaan, Marianne M

    2014-01-01

    Regular exercise testing in Warmblood sport horses may, as in racing, potentially help to characterise fitness indices in different disciplines and at various competition levels and assist in understanding when a horse is 'fit to compete'. In this review an overview is given of the current state of

  20. Preparing Undergraduate Students for the Major Field Test in Business

    Science.gov (United States)

    Bisalski, Heather Cooper; Helms, Marilyn M.; Whitesell, Melissa

    2017-01-01

    Many business programs address the learning of undergraduate students with an exit exam. A reference librarian and the business school faculty created an online test preparation study guide (or LibGuide) which included no-cost resources that were readily available yet academically authoritative to aid students in studying for the Educational…

  1. Data Modeling for Measurements in the Metrology and Testing Fields

    CERN Document Server

    Pavese, Franco

    2009-01-01

    Offers a comprehensive set of modeling methods for data and uncertainty analysis. This work develops methods and computational tools to address general models that arise in practice, allowing for a more valid treatment of calibration and test data and providing an understanding of complex situations in measurement science

  2. Preparing Undergraduate Students for the Major Field Test in Business

    Science.gov (United States)

    Bisalski, Heather Cooper; Helms, Marilyn M.; Whitesell, Melissa

    2017-01-01

    Many business programs address the learning of undergraduate students with an exit exam. A reference librarian and the business school faculty created an online test preparation study guide (or LibGuide) which included no-cost resources that were readily available yet academically authoritative to aid students in studying for the Educational…

  3. Exercise testing in Warmblood sport horses under field conditions

    NARCIS (Netherlands)

    Munsters, Carolien C B M; van Iwaarden, Alexandra; van Weeren, René|info:eu-repo/dai/nl/074628550; Sloet van Oldruitenborgh-Oosterbaan, Marianne M|info:eu-repo/dai/nl/075234394

    2014-01-01

    Regular exercise testing in Warmblood sport horses may, as in racing, potentially help to characterise fitness indices in different disciplines and at various competition levels and assist in understanding when a horse is 'fit to compete'. In this review an overview is given of the current state of

  4. Pilot Implementation: Learning from Field Tests in IS Development

    DEFF Research Database (Denmark)

    Herzum, Morten; Bansler, Jørgen P.; Havn, Erling C.

    2012-01-01

    A recurrent problem in information-systems development (ISD) is that many design shortcomings are not detected during development, but first after the system has been delivered and implemented in its intended environment. Pilot implementations appear to promise a way to extend prototyping from...... the laboratory to the field, thereby allowing users to experience a system design under realistic conditions and developers to get feedback from realistic use while the design is still malleable. We characterize pilot implementation, contrast it with prototyping, propose a fiveelement model of pilot...

  5. Solar photovoltaic field tests and applications project. Quarterly technical report, April 1-June 30, 1978

    Energy Technology Data Exchange (ETDEWEB)

    none,

    1979-09-01

    Field tests for a variety of both large and small experimental photovoltaic systems are summarized. Support activities in the areas of power conditioning, control, and storage; materials, processes, and testing; and data acquisition are reviewed. (MHR)

  6. Locating Microseismic Events Using Fat-Ray Double-Difference Tomography for Monitoring CO2 Injection at the Aneth EOR Field

    Science.gov (United States)

    Chen, T.; Huang, L.; Rutledge, J. T.

    2014-12-01

    During CO2 injection, the increase in pore pressure and volume may change stress distribution in the field, and induce microseismic events as brittle failure on small faults or fractures. An accurate location of these induced microseismic events can help understand the migration of CO2 and stress evolution in the reservoir. A geophone string spanning 800-1700 m in depth was cemented into a monitoring well at the Aneth oil field in Utah in 2007 for monitoring CO2 injection for enhanced oil recovery (EOR). The monitoring continued till 2010. A total of 24 geophone levels recorded induced microseismic events, including 18 levels of three-component geophones and six vertical-component levels spaced 106.7 m (350 ft) apart to take full advantage of the entire array aperture. We apply a fat-ray double-difference tomography method to microseismic data acquired at the Aneth EOR field. We obtain high-precision locations of microseismic events and improve the velocity structure simultaneously. We demonstrate the improvements by comparing our results with those obtained using the conventional double-difference tomography.

  7. Groundwater Chemistry Changes as a Result of CO2 Injection at the ZERT Field Site in Bozeman, Montana

    Energy Technology Data Exchange (ETDEWEB)

    Apps, J.A.; Birkholzer, J.T.; Spycher, N.; Zheng, L.; Herkelrath, W.N.; Kharaka, Y.K.; Thordsen, J.J.; Kakouros, E.; Beers, S; Gullickson, K.S.; Spangler, L.H.; Ambats, G.

    2009-11-01

    Combustion of fossil fuels produces CO{sub 2}, a common greenhouse gas linked to global climate change. Separation of CO{sub 2}from emissions produced by large industrial point sources like power plants, cement kilns and refineries, and injection deep nderground into geologic formations is one method of preventing CO{sub 2} releases into the atmosphere. This process is referred to as Carbon Capture and Storage (CCS). CCS is one of several solutions being considered to mitigate global climate change. Other solutions nclude increased energy efficiency, renewables, nuclear power, advanced coal, and plug-in hybrid electric vehicles.

  8. Cosmological tests of an axiverse-inspired quintessence field

    CERN Document Server

    Emami, Razieh; Pradler, Josef; Raccanelli, Alvise; Kamionkowski, Marc

    2016-01-01

    Inspired by the string axiverse idea, it has been suggested that the recent transition from decelerated to accelerated cosmic expansion is driven by an axion-like quintessence field with a sub-Planckian decay constant. The scenario requires that the axion field be rather near the maximum of its potential, but is less finely tuned than other explanations of cosmic acceleration. The model is parametrized by an axion decay constant $f$, the axion mass $m$, and an initial misalignment angle $|\\theta_i|$ which is close to $\\pi$. In order to determine the $m$ and $\\theta_{i}$ values consistent with observations, these parameters are mapped onto observables: the Hubble parameter $H(z)$ at and angular diameter distance $d_{A}(z)$ to redshift $z= 0.57$, as well as the angular sound horizon of the cosmic microwave background (CMB). Measurements of the baryon acoustic oscillation (BAO) scale at $z\\simeq 0.57$ by the BOSS survey and Planck measurements of CMB temperature anisotropies are then used to probe the $\\left\\{m,...

  9. Bacteria endotoxin test of Vitamin B Co. Injection%复合维生素B注射液细菌内毒素检查法的研究

    Institute of Scientific and Technical Information of China (English)

    刘骅; 武谷

    2011-01-01

    Aim To establish the bacterial endotoxin test for Vitamin B Co. Injection. Methods The experiment was carried out according to the appendix of Chinese Pharmacopeia in 2005 Edition (Vol Ⅱ ). Results The reactions with two Tachypleus Amebocyte Lysate manufacturers were not disturbed in minimus diluted multiple for Vitamin B Co. Injection,which was one ratio sixteen. The endotoxin limit of Vitamin B Co. Injection was 5 EU · ml -1. Conclusion It is feasible to control quality of Vitamin B Co. Injection by bacterial endotoxin test.%目的 建立复合维生素B注射液的细菌内毒素检查方法.方法 根据2005年版二部附录细菌内毒素检查法,采用2个不同生产厂家的鲎试剂对复合维生素B注射液进行研究.结果 复合维生素B注射液最小不干扰稀释倍数为1: 16,细菌内毒素限值为5 EU·ml-1.结论 采用细菌内毒素检查法控制复合维生素B注射液的质量是可行的.

  10. Antagonism of meta-chlorophenylpiperazine-induced inhibition of exploratory activity in an emergence procedure, the open field test, in rats.

    Science.gov (United States)

    Meert, T F; Melis, W; Aerts, N; Clincke, G

    1997-08-01

    The effects of meta-chlorophenylpiperazine (mCPP) were studied on exploratory behaviour in the open field test, using a procedure designed to evaluate the emergence of rats into a novel environment. mCPP reduced the exploratory activity in a dose-related manner after subcutaneous (s.c.), intraperitoneal (i.p.) and intravenous (i.v.) administration. The inhibition was manifest in all the parameters used to quantify the exploration of the open field area. Additional neuroendocrine experiments in a parallel group of rats revealed a dose-related increase in plasma prolactin and ACTH levels after i.v. mCPP, pointing to a general state of arousal in these mCPP-treated animals. A number of 5-HT antagonists were tested for their ability to prevent or reverse the behavioural inhibition induced by an i.v. injection of 1.0 g/kg mCPP given 15 min before testing in the open field. The antagonists were injected s.c. or given orally at various time intervals before mCPP, or they were injected i.v. 10 min after mCPP. The lowest active doses for the attentuation of the mCPP-induced behavioural inhibition after s.c., oral and i.v. administration, respectively, were 0.04, 40 and 10 mg/kg for pizotifen; 0.16, 0.16 and 0.16 mg/kg for mianserin; 0.63, 0.16 and 0.16 mg/kg for methysergide, and 0.16, 2.5 and 2.5 mg/kg for ritanserin. The lowest active doses of mirtazapine after s.c. and i.v. treatment were 0.01 and 0.16 mg/kg. These data indicate that mixed 5-HT1/5-HT2 receptor antagonists such as pizotifen and methysergide, and mixed 5-HT and catecholamine antagonists such as mianserin and mirtazapine are more potent antagonists of mCPP-induced behavioural inhibition in rats than the more selective 5-HT2A/5-HT2C antagonist ritanserin.

  11. Spinning test particles in a Kerr field - I

    Science.gov (United States)

    Semerák, O.

    1999-09-01

    Mathisson-Papapetrou equations are solved numerically to obtain trajectories of spinning test particles in (the meridional section of) the Kerr space-time. The supplementary conditions p_σS^μσ=0 are used to close the system of equations. The results show that in principle a spin-curvature interaction may lead to considerable deviations from geodesic motion, although in astrophysical situations of interest probably no large spin effects can be expected for values of spin consistent with a pole-dipole test-particle approximation. However, a significant cumulative effect may occur, e.g. in the inspiral of a spinning particle on to a rotating compact body, that would modify gravitational waves generated by such a system. A thorough literature review is included in the paper.

  12. CX-100 and TX-100 blade field tests.

    Energy Technology Data Exchange (ETDEWEB)

    Holman, Adam (USDA-Agriculture Research Service, Bushland, TX); Jones, Perry L.; Zayas, Jose R.

    2005-12-01

    In support of the DOE Low Wind Speed Turbine (LWST) program two of the three Micon 65/13M wind turbines at the USDA Agricultural Research Service (ARS) center in Bushland, Texas will be used to test two sets of experimental blades, the CX-100 and TX-100. The blade aerodynamic and structural characterization, meteorological inflow and wind turbine structural response will be monitored with an array of 75 instruments: 33 to characterize the blades, 15 to characterize the inflow, and 27 to characterize the time-varying state of the turbine. For both tests, data will be sampled at a rate of 30 Hz using the ATLAS II (Accurate GPS Time-Linked Data Acquisition System) data acquisition system. The system features a time-synchronized continuous data stream and telemetered data from the turbine rotor. This paper documents the instruments and infrastructure that have been developed to monitor these blades, turbines and inflow.

  13. Testing Einstein's Equivalence Principle with Supercluster Laniakea's Gravitational Field

    OpenAIRE

    Luo, Zhi-Xing; Zhang, Bo; Wei, Jun-Jie; Wu, Xue-Feng

    2016-01-01

    Comparing the parameterized post-Newtonian parameter $\\gamma$ values for different types of particles, or the same type of particles with different energies is an important method to test the Einstein Equivalence Principle (EEP). Assuming that the observed time delays are dominated by the gravitational potential of the Laniakea supercluster of galaxies, better results of EEP constraints can be obtained. In this paper, we apply photons from three kinds of cosmic transients, including TeV blaza...

  14. Effects of magnetic field orientation and injected current density on the output of nano-structured Co/Cu/Fe junctions

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Co/Cu/Fe nano-sized sandwich thin films have been prepared by electron beam evaporation. 5 μm×5 μm Co/Cu/Fe sandwich heterojunction was made using photolithography and lift-off process. The bipolar output signal of Co/Cu/Fe junctions has been measured and analyzed. The effects of applied magnetic field angle (referring to the normal of the junction plane) and injecting spin-polarized current on the output signals have been studied, and the measured results were discussed.

  15. Laboratory and field tests of corrosion inhibitors for an offshore application

    Energy Technology Data Exchange (ETDEWEB)

    Skjerve, Sofie; Fuhr, Geir Gundersen; Haldogaard, Geir

    2006-03-15

    Statoil started a R and D-project in 2002 where the goal was to implement environmental friendly corrosion control at a Statoil operated oil producing field. In this project the following tasks have been addressed: 1) Reduction of the chemical consumption. 2) Documentation of the discharge level of the corrosion inhibitor. 3) Documentation of the environmental impact. 4) Development of new environmentally friendly acceptable corrosion inhibitors. 5) Laboratory and field testing of new corrosion inhibitors. This paper describes laboratory and field tests of corrosion inhibitors for this project. The field tests were carried out on an offshore oil producing installation in the North Sea. Five corrosion inhibitor suppliers with totally eleven products were taking part in this test. All the products were tested in the laboratory. The four most promising products from the laboratory tests were tested in the field during a fourteen days offshore test. Only one of the tested products gave satisfactory results from the corrosion field test. Corrosion measurements were performed both with a Zero Resistance Ammetry (ZRA) probe installed directly into a flow line and with two side streams units. One side stream unit was connected upstream the test separator and the other unit was connected downstream the test separator. (author) (tk)

  16. Exploration 3-D Seismic Field Test/Native Tribes Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Carroll, Herbert B.; Chen, K.C.; Guo, Genliang; Johnson, W.I.;