WorldWideScience

Sample records for fibrin gels measured

  1. Silk-fibrin/hyaluronic acid composite gels for nucleus pulposus tissue regeneration.

    Science.gov (United States)

    Park, Sang-Hyug; Cho, Hongsik; Gil, Eun Seok; Mandal, Biman B; Min, Byoung-Hyun; Kaplan, David L

    2011-12-01

    Scaffold designs are critical for in vitro culture of tissue-engineered cartilage in three-dimensional environments to enhance cellular differentiation for tissue engineering and regenerative medicine. In the present study we demonstrated silk and fibrin/hyaluronic acid (HA) composite gels as scaffolds for nucleus pulposus (NP) cartilage formation, providing both biochemical support for NP outcomes as well as fostering the retention of size of the scaffold during culture due to the combined features of the two proteins. Passage two (P2) human chondrocytes cultured in 10% serum were encapsulated within silk-fibrin/HA gels. Five study groups with fibrin/HA gel culture (F/H) along with varying silk concentrations (2% silk gel only, fibrin/HA gel culture with 1% silk [F/H+1S], 1.5% silk [F/H+1.5S], and 2% silk [F/H+2S]) were cultured in serum-free chondrogenic defined media (CDM) for 4 weeks. Histological examination with alcian blue showed a defined chondrogenic area at 1 week in all groups that widened homogenously until 4 weeks. In particular, chondrogenic differentiation observed in the F/H+1.5S had no reduction in size throughout the culture period. The results of biochemical and molecular biological evaluations supported observations made during histological examination. Mechanical strength measurements showed that the silk mixed gels provided stronger mechanical properties for NP tissue than fibrin/HA composite gels in CDM. This effect could potentially be useful in the study of in vitro NP tissue engineering as well as for clinical implications for NP tissue regeneration.

  2. Characterization of Fibrin and Collagen Gels for Engineering Wound Healing Models

    Directory of Open Access Journals (Sweden)

    Oihana Moreno-Arotzena

    2015-04-01

    Full Text Available Hydrogels are used for 3D in vitro assays and tissue engineering and regeneration purposes. For a thorough interpretation of this technology, an integral biomechanical characterization of the materials is required. In this work, we characterize the mechanical and functional behavior of two specific hydrogels that play critical roles in wound healing, collagen and fibrin. A coherent and complementary characterization was performed using a generalized and standard composition of each hydrogel and a combination of techniques. Microstructural analysis was performed by scanning electron microscopy and confocal reflection imaging. Permeability was measured using a microfluidic-based experimental set-up, and mechanical responses were analyzed by rheology. We measured a pore size of 2.84 and 1.69 μm for collagen and fibrin, respectively. Correspondingly, the permeability of the gels was 1.00·10−12 and 5.73·10−13 m2. The shear modulus in the linear viscoelastic regime was 15 Pa for collagen and 300 Pa for fibrin. The gels exhibited strain-hardening behavior at ca. 10% and 50% strain for fibrin and collagen, respectively. This consistent biomechanical characterization provides a detailed and robust starting point for different 3D in vitro bioapplications, such as collagen and/or fibrin gels. These features may have major implications for 3D cellular behavior by inducing divergent microenvironmental cues.

  3. Scaffold architecture and fibrin gels promote meniscal cell proliferation

    Energy Technology Data Exchange (ETDEWEB)

    Pawelec, K. M., E-mail: pawelec.km@gmail.com, E-mail: jw626@cam.ac.uk; Best, S. M.; Cameron, R. E. [Cambridge Centre for Medical Materials, Materials Science and Metallurgy Department, University of Cambridge, Cambridge CB3 0FS (United Kingdom); Wardale, R. J., E-mail: pawelec.km@gmail.com, E-mail: jw626@cam.ac.uk [Division of Trauma and Orthopaedic Surgery, Department of Surgery, University of Cambridge, Cambridge CB2 2QQ (United Kingdom)

    2015-01-01

    Stability of the knee relies on the meniscus, a complex connective tissue with poor healing ability. Current meniscal tissue engineering is inadequate, as the signals for increasing meniscal cell proliferation have not been established. In this study, collagen scaffold structure, isotropic or aligned, and fibrin gel addition were tested. Metabolic activity was promoted by fibrin addition. Cellular proliferation, however, was significantly increased by both aligned architectures and fibrin addition. None of the constructs impaired collagen type I production or triggered adverse inflammatory responses. It was demonstrated that both fibrin gel addition and optimized scaffold architecture effectively promote meniscal cell proliferation.

  4. Plasminogen activator activity and plasma-coagulum lysis measured by use of optimized fibrin gel structure preformed in microtiter plates

    DEFF Research Database (Denmark)

    Sidelmann, Johannes Jakobsen; Jespersen, J; Gram, J

    1995-01-01

    We introduce a new fibrin plate assay performed in microtiter plates. By means of spectroscopic studies we optimized the structure of the fibrin gel and then used the optimized fibrin gel to determine plasminogen activator activity. Plasminogen activator solutions were applied on top of the fibri...

  5. A novel fibrin gel derived from hyaluronic acid-grafted fibrinogen

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Chiung L; Chen, Hui W; Wang, Tzu C; Wang, Yng J, E-mail: wang@ym.edu.tw [Institute of Biomedical Engineering, National Yang Ming University, No. 155, Sec. 2, Li-Nung St., Shih-Pai, Taipei, Taiwan 112 (China)

    2011-04-15

    Fibrinogen is a major plasma protein that forms a three-dimensional fibrin gel upon being activated by thrombin. In this study, we report the synthesis and potential applications of hybrid molecules composed of fibrinogen coupled to the reducing ends of short-chain hyaluronic acids (sHAs) by reductive amination. The grafting of sHAs to fibrinogen was verified by analyzing particle size, zeta potential and gel-electrophoretic mobility of the hybrid molecules. The sHA-fibrinogen hybrid molecules with graft ratios (sHA/fibrinogen) of up to 6.5 retained the ability to form gels in response to thrombin activation. The sHA-fibrin gels were transparent in appearance and exhibited high water content, which were characteristics distinct from those of gels formed by mixtures of sHAs and fibrinogen. The potential applications of the sHA-fibrin gels were evaluated. The sHA-fibrinogen gel with a graft ratio of 3.6 (S3.6F) was examined for its ability to encapsulate and support the differentiation of ATDC5 chondrocyte-like cells. Compared with the fibrinogen-formed gel, cells cultured in the S3.6F gel exhibited increased lacunae formation; moreover, the abundance of cartilaginous extracellular matrix molecules and the expression of chondrocyte marker genes, such as aggrecan, collagen II and Sox9, were also significantly increased. Our data suggest that the three-dimensional gel formed by the sHA-fibrinogen hybrid is a better support than the fibrin gel for chondrogenesis induction.

  6. A novel fibrin gel derived from hyaluronic acid-grafted fibrinogen

    International Nuclear Information System (INIS)

    Yang, Chiung L; Chen, Hui W; Wang, Tzu C; Wang, Yng J

    2011-01-01

    Fibrinogen is a major plasma protein that forms a three-dimensional fibrin gel upon being activated by thrombin. In this study, we report the synthesis and potential applications of hybrid molecules composed of fibrinogen coupled to the reducing ends of short-chain hyaluronic acids (sHAs) by reductive amination. The grafting of sHAs to fibrinogen was verified by analyzing particle size, zeta potential and gel-electrophoretic mobility of the hybrid molecules. The sHA-fibrinogen hybrid molecules with graft ratios (sHA/fibrinogen) of up to 6.5 retained the ability to form gels in response to thrombin activation. The sHA-fibrin gels were transparent in appearance and exhibited high water content, which were characteristics distinct from those of gels formed by mixtures of sHAs and fibrinogen. The potential applications of the sHA-fibrin gels were evaluated. The sHA-fibrinogen gel with a graft ratio of 3.6 (S3.6F) was examined for its ability to encapsulate and support the differentiation of ATDC5 chondrocyte-like cells. Compared with the fibrinogen-formed gel, cells cultured in the S3.6F gel exhibited increased lacunae formation; moreover, the abundance of cartilaginous extracellular matrix molecules and the expression of chondrocyte marker genes, such as aggrecan, collagen II and Sox9, were also significantly increased. Our data suggest that the three-dimensional gel formed by the sHA-fibrinogen hybrid is a better support than the fibrin gel for chondrogenesis induction.

  7. Fabrication and physical and biological properties of fibrin gel derived from human plasma

    Science.gov (United States)

    Zhao, Haiguang; Ma, Lie; Zhou, Jie; Mao, Zhengwei; Gao, Changyou; Shen, Jiacong

    2008-03-01

    The fast development of tissue engineering and regenerative medicine drives the old biomaterials, for example, fibrin glue, to find new applications in these areas. Aiming at developing a commercially available hydrogel for cell entrapment and delivery, in this study we optimized the fabrication and gelation conditions of fibrin gel. Fibrinogen was isolated from human plasma by a freeze-thaw circle. Gelation of the fibrinogen was accomplished by mixing with thrombin. Absorbance of the fibrinogen/thrombin mixture at 550 nm as a function of reaction time was monitored by UV-VIS spectroscopy. It was found that the clotting time is significantly influenced by the thrombin concentration and the temperature, while less influenced by the fibrinogen concentration. After freeze-drying, the fibrin gel was characterized by scanning electron microscopy (SEM), revealing fibrous microstructure. Thermal gravimetric analysis found that the degradation temperature of the crosslinked fibrin gel starts from 288 °C, which is about 30 °C higher than that of the fibrinogen. The hydrogel has an initial water-uptake ratio of ~50, decreased to 30-40 after incubation in water for 11 h depending on the thrombin concentration. The fibrin gels lost their weights in PBS very rapidly, while slowly in DMEM/fetal bovine serum and DMEM. In vitro cell culture found that human fibroblasts could normally proliferate in the fibrin gel with spreading morphology. In conclusion, the fibrin gel containing higher concentration of fibrinogen (20 mg ml-1) and thrombin (5 U ml-1) has suitable gelation time and handling properties, and thus is applicable as a delivery vehicle for cells such as fibroblasts.

  8. Ultrastructure and growth factor content of equine platelet-rich fibrin gels.

    Science.gov (United States)

    Textor, Jamie A; Murphy, Kaitlin C; Leach, J Kent; Tablin, Fern

    2014-04-01

    To compare fiber diameter, pore area, compressive stiffness, gelation properties, and selected growth factor content of platelet-rich fibrin gels (PRFGs) and conventional fibrin gels (FGs). PRFGs and conventional FGs prepared from the blood of 10 healthy horses. Autologous fibrinogen was used to form conventional FGs. The PRFGs were formed from autologous platelet-rich plasma of various platelet concentrations (100 × 10³ platelets/μL, 250 × 10³ platelets/μL, 500 × 10³ platelets/μL, and 1,000 × 10³ platelets/μL). All gels contained an identical fibrinogen concentration (20 mg/mL). Fiber diameter and pore area were evaluated with scanning electron microscopy. Maximum gelation rate was assessed with spectrophotometry, and gel stiffness was determined by measuring the compressive modulus. Gel weights were measured serially over 14 days as an index of contraction (volume loss). Platelet-derived growth factor-BB and transforming growth factor-β1 concentrations were quantified with ELISAs. Fiber diameters were significantly larger and mean pore areas were significantly smaller in PRFGs than in conventional FGs. Gel weight decreased significantly over time, differed significantly between PRFGs and conventional FGs, and was significantly correlated with platelet concentration. Platelet-derived growth factor-BB and transforming growth factor-β1 concentrations were highest in gels and releasates derived from 1,000 × 10³ platelets/μL. The inclusion of platelets in FGs altered the architecture and increased the growth factor content of the resulting scaffold. Platelets may represent a useful means of modifying these gels for applications in veterinary and human regenerative medicine.

  9. Fibrin gel as a scaffold for skin substitute – production and clinical experience.

    Science.gov (United States)

    Kljenak, Antun; Tominac Trcin, Mirna; Bujić, Marina; Dolenec, Tamara; Jevak, Martina; Mršić, Gordan; Zmiš, Gordana; Barčot, Zoran; Muljačić, Ante; Popović, Maja

    2016-06-01

    The purpose of this study was to create a fibrin-based human skin substitute in vitro with epidermal and dermal component and to assess its healing potential in deep partial and full thickness burns. Fibrin scaffolds were prepared from commercial fibrin glue kits. Human fibroblasts were cultured in fibrin gel. Human keratinocytes were seeded on the top of the gel. Viability of cells was determined fluorimetrically. Scanning electron microscope and immunocytochemistry analysis of cultured cells were performed. After hydrosurgical preparation of deep burn necrotic tissue, wound bed was prepared for skin substitutes. Progress of healing was documented using visual estimation and photos. Scanning electron microscope images showed good cell attachment and colony spreading of keratinocytes and fibroblasts on fibrin scaff old. Immunofluorescent staining of cell cultures on fibrin scaffold showed expression of vimentin, a marker of fibroblast cells, cytokeratin 19, a marker of epithelial stem cells, as well as involucrin, a marker of differentiated keratinocytes. Clinical results clearly showed that appearance of the skin did not differ significantly from the areas of transplanted skin using split-thickness skin graft techniques. In conclusion, using these fibrin-cultured autografts on massive full-thickness burn resulted in good healing.

  10. Silver-Stained Fibrin Zymography: Separation of Proteases and Activity Detection Using a Single Substrate-Containing Gel.

    Science.gov (United States)

    Park, Chang-Su; Kang, Dae-Ook; Choi, Nack-Shick

    2017-01-01

    Silver-stained fibrin zymography for separation of protease bands and activity detection using a single substrate gel was designed. The method takes advantage of the nano-scale sensitivity of both zymography and silver staining. After sodium dodecyl sulfate (SDS) polyacrylamide gel electrophoresis (PAGE) in a gel containing fibrin (protease substrate), the gel was incubated in enzyme reaction buffer and the zymogram gel was silver-stained. Bands with protease activity were stained with silver in clear areas where the protein substrate had been degraded. The molecular sizes of proteases were accurately determined.

  11. Local and global deformations in a strain-stiffening fibrin gel

    Energy Technology Data Exchange (ETDEWEB)

    Wen Qi [Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA 19104 (United States); Basu, Anindita [Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA 19104 (United States); Winer, Jessamine P [Institute for Medicine and Engineering, University of Pennsylvania, Philadelphia, PA 19104 (United States); Yodh, Arjun [Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA 19104 (United States); Janmey, Paul A [Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA 19104 (United States)

    2007-11-15

    Extracellular matrices composed of filamentous biopolymers like collagen and fibrin have viscoelastic properties that differ from those of rubberlike elastomers or hydrogels formed by flexible polymers. Compared to flexible polymer gels, filamentous biopolymer networks generally have larger elastic moduli, a striking increase in elastic modulus with increasing strain, and a pronounced negative normal stress when deformed in simple shear. All three of these unusual features can be accounted for by a theory that extends concepts of entropic elasticity to a regime where the polymer chains are already significantly extended in the absence of external forces because of their finite bending stiffness. An essential assumption of the theories that relate microscopic structural parameters such as persistence length and mesh size of biopolymer gels to their macroscopic rheology is that the deformation of these materials is affine: that is, the macroscopic strain of the bulk material is equal to the local strain within the material at each point. The validity of this assumption for the dilute open meshworks of most biopolymer gels has been experimentally tested by embedding micron diameter fluorescent beads within the networks formed by fibrin and quantifying their displacements as the macroscopic samples are deformed in a rheometer. Measures of non-affine deformation are small at small strains and decrease as strain increases and the sample stiffens. These results are consistent with the entropic model for non-linear elasticity of semiflexible polymer networks and show that strain-stiffening does not require non-affine deformations.

  12. Cyclic compression maintains viability and induces chondrogenesis of human mesenchymal stem cells in fibrin gel scaffolds.

    Science.gov (United States)

    Pelaez, Daniel; Huang, Chun-Yuh Charles; Cheung, Herman S

    2009-01-01

    Mechanical loading has long been shown to modulate cartilage-specific extracellular matrix synthesis. With joint motion, cartilage can experience mechanical loading in the form of compressive, tensile or shearing load, and hydrostatic pressure. Recent studies have demonstrated the capacity of unconfined cyclic compression to induce chondrogenic differentiation of human mesenchymal stem cell (hMSC) in agarose culture. However, the use of a nonbiodegradable material such as agarose limits the applicability of these constructs. Of the possible biocompatible materials available for tissue engineering, fibrin is a natural regenerative scaffold, which possesses several desired characteristics including a controllable degradation rate and low immunogenicity. The objective of the present study was to determine the capability of fibrin gels for supporting chondrogenesis of hMSCs under cyclic compression. To optimize the system, three concentrations of fibrin gel (40, 60, and 80 mg/mL) and three different stimulus frequencies (0.1, 0.5, and 1.0 Hz) were used to examine the effects of cyclic compression on viability, proliferation and chondrogenic differentiation of hMSCs. Our results show that cyclic compression (10% strain) at frequencies >0.5 Hz and gel concentration of 40 mg/mL fibrinogen appears to maintain cellular viability within scaffolds. Similarly, variations in gel component concentration and stimulus frequency can be modified such that a significant chondrogenic response can be achieved by hMSC in fibrin constructs after 8 h of compression spread out over 2 days. This study demonstrates the suitability of fibrin gel for supporting the cyclic compression-induced chondrogenesis of mesenchymal stem cells.

  13. A safe and efficient method to retrieve mesenchymal stem cells from three-dimensional fibrin gels.

    Science.gov (United States)

    Carrion, Bita; Janson, Isaac A; Kong, Yen P; Putnam, Andrew J

    2014-03-01

    Mesenchymal stem cells (MSCs) display multipotent characteristics that make them ideal for potential therapeutic applications. MSCs are typically cultured as monolayers on tissue culture plastic, but there is increasing evidence suggesting that they may lose their multipotency over time in vitro and eventually cease to retain any resemblance to in vivo resident MSCs. Three-dimensional (3D) culture systems that more closely recapitulate the physiological environment of MSCs and other cell types are increasingly explored for their capacity to support and maintain the cell phenotypes. In much of our own work, we have utilized fibrin, a natural protein-based material that serves as the provisional extracellular matrix during wound healing. Fibrin has proven to be useful in numerous tissue engineering applications and has been used clinically as a hemostatic material. Its rapid self-assembly driven by thrombin-mediated alteration of fibrinogen makes fibrin an attractive 3D substrate, in which cells can adhere, spread, proliferate, and undergo complex morphogenetic programs. However, there is a significant need for simple cost-effective methods to safely retrieve cells encapsulated within fibrin hydrogels to perform additional analyses or use the cells for therapy. Here, we present a safe and efficient protocol for the isolation of MSCs from 3D fibrin gels. The key ingredient of our successful extraction method is nattokinase, a serine protease of the subtilisin family that has a strong fibrinolytic activity. Our data show that MSCs recovered from 3D fibrin gels using nattokinase are not only viable but also retain their proliferative and multilineage potentials. Demonstrated for MSCs, this method can be readily adapted to retrieve any other cell type from 3D fibrin gel constructs for various applications, including expansion, bioassays, and in vivo implantation.

  14. Modeling of Fibrin Gels Based on Confocal Microscopy and Light-Scattering Data

    Science.gov (United States)

    Magatti, Davide; Molteni, Matteo; Cardinali, Barbara; Rocco, Mattia; Ferri, Fabio

    2013-01-01

    Fibrin gels are biological networks that play a fundamental role in blood coagulation and other patho/physiological processes, such as thrombosis and cancer. Electron and confocal microscopies show a collection of fibers that are relatively monodisperse in diameter, not uniformly distributed, and connected at nodal points with a branching order of ∼3–4. Although in the confocal images the hydrated fibers appear to be quite straight (mass fractal dimension Dm = 1), for the overall system 1gels made of cylindrical sticks of diameter d, density ρ, and average length 〈L〉, joined at randomly distributed nodal points. The resulting 3D network strikingly resembles real fibrin gels and can be sketched as an assembly of densely packed fractal blobs, i.e., regions of size ξ, where the fiber concentration is higher than average. The blobs are placed at a distance ξ0 between their centers of mass so that they are overlapped by a factor η = ξ/ξ0 and have Dm ∼1.2–1.6. The in silico gels’ structure is quantitatively analyzed by its 3D spatial correlation function g3D(r) and corresponding power spectrum I(q) = FFT3D[g3D(r)], from which ρ, d, Dm, η, and ξ0 can be extracted. In particular, ξ0 provides an excellent estimate of the gel mesh size. The in silico gels’ I(q) compares quite well with real gels’ elastic light-scattering measurements. We then derived an analytical form factor for accurately fitting the scattering data, which allowed us to directly recover the gels’ structural parameters. PMID:23473498

  15. Retina tissue engineering by conjunctiva mesenchymal stem cells encapsulated in fibrin gel: Hypotheses on novel approach to retinal diseases treatment.

    Science.gov (United States)

    Soleimannejad, Mostafa; Ebrahimi-Barough, Somayeh; Nadri, Samad; Riazi-Esfahani, Mohammad; Soleimani, Masoud; Tavangar, Seyed Mohammad; Ai, Jafar

    2017-04-01

    Retinitis pigmentosa (RP) and age related macular degeneration (AMD) are two retinal diseases that progress by photoreceptor cells death. In retinal transplantation studies, stem and progenitor cells inject into the sub retinal space or vitreous and then these cells can be migrate to the site of retinal degeneration and locate in the host retina and restitute vision. Our hypothesis suggests that using human conjunctiva stem cells (as the source for increasing the number of human stem cells progenitor cells in retina dysfunction diseases) with fibrin gel and also assessing its relating in vitro (cellular and molecular processes) and in vivo (vision tests and pathology) could be a promising strategy for treatment of AMD and RP disorders. In this idea, we describe a novel approach for retina tissue engineering with differentiation of conjunctiva mesenchymal stem cells (CJMSCs) into photoreceptor-like cells in fibrin gel with induction medium contain taurine. For assessment of differentiation, immunocytochemistry and real time PCR are used for the expression of Rhodopsin, RPE65, Nestin as differentiated photoreceptor cell markers in 2D and 3D culture. The results show that fibrin gel will offer a proper 3D scaffold for CJMSCs derived photoreceptor cell-like cells. Application of immune-privileged, readily available sources of adult stem cells like human conjunctiva stem cells with fibrin gel would be a promising strategy to increase the number of photoreceptor progenitor cells and promote involuntary angiogenesis needed in retina layer repair and regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Concentration independent modulation of local micromechanics in a fibrin gel.

    Directory of Open Access Journals (Sweden)

    Maxwell A Kotlarchyk

    Full Text Available Methods for tuning extracellular matrix (ECM mechanics in 3D cell culture that rely on increasing the concentration of either protein or cross-linking molecules fail to control important parameters such as pore size, ligand density, and molecular diffusivity. Alternatively, ECM stiffness can be modulated independently from protein concentration by mechanically loading the ECM. We have developed a novel device for generating stiffness gradients in naturally derived ECMs, where stiffness is tuned by inducing strain, while local mechanical properties are directly determined by laser tweezers based active microrheology (AMR. Hydrogel substrates polymerized within 35 mm diameter Petri dishes are strained non-uniformly by the precise rotation of an embedded cylindrical post, and exhibit a position-dependent stiffness with little to no modulation of local mesh geometry. Here we present the device in the context of fibrin hydrogels. First AMR is used to directly measure local micromechanics in unstrained hydrogels of increasing fibrin concentration. Changes in stiffness are then mapped within our device, where fibrin concentration is held constant. Fluorescence confocal imaging and orbital particle tracking are used to quantify structural changes in fibrin on the micro and nano levels respectively. The micromechanical strain stiffening measured by microrheology is not accompanied by ECM microstructural changes under our applied loads, as measured by confocal microscopy. However, super-resolution orbital tracking reveals nanostructural straightening, lengthening, and reduced movement of fibrin fibers. Furthermore, we show that aortic smooth muscle cells cultured within our device are morphologically sensitive to the induced mechanical gradient. Our results demonstrate a powerful cell culture tool that can be used in the study of mechanical effects on cellular physiology in naturally derived 3D ECM tissues.

  17. In search of a consensus terminology in the field of platelet concentrates for surgical use: platelet-rich plasma (PRP), platelet-rich fibrin (PRF), fibrin gel polymerization and leukocytes.

    Science.gov (United States)

    Dohan Ehrenfest, David M; Bielecki, Tomasz; Mishra, Allan; Borzini, Piero; Inchingolo, Francesco; Sammartino, Gilberto; Rasmusson, Lars; Everts, Peter A

    2012-06-01

    In the field of platelet concentrates for surgical use, most products are termed Platelet-Rich Plasma (PRP). Unfortunately, this term is very general and incomplete, leading to many confusions in the scientific database. In this article, a panel of experts discusses this issue and proposes an accurate and simple terminology system for platelet concentrates for surgical use. Four main categories of products can be easily defined, depending on their leukocyte content and fibrin architecture: Pure Platelet-Rich Plasma (P-PRP), such as cell separator PRP, Vivostat PRF or Anitua's PRGF; Leukocyteand Platelet-Rich Plasma (L-PRP), such as Curasan, Regen, Plateltex, SmartPReP, PCCS, Magellan, Angel or GPS PRP; Pure Plaletet-Rich Fibrin (P-PRF), such as Fibrinet; and Leukocyte- and Platelet-Rich Fibrin (L-PRF), such as Choukroun's PRF. P-PRP and L-PRP refer to the unactivated liquid form of these products, their activated versions being respectively named P-PRP gels and L-PRP gels. The purpose of this search for a terminology consensus is to plead for a more serious characterization of these products. Researchers have to be aware of the complex nature of these living biomaterials, in order to avoid misunderstandings and erroneous conclusions. Understanding the biomaterials or believing in the magic of growth factors ? From this choice depends the future of the field.

  18. Three-dimensional structure and cytokine distribution of platelet-rich fibrin.

    Science.gov (United States)

    Bai, Meng-Yi; Wang, Ching-Wei; Wang, Jyun-Yi; Lin, Ming-Fang; Chan, Wing P

    2017-02-01

    Previous reports have revealed that several cytokines (including platelet-derived growth factor-BB, transforming growth factors-β1 and insulin-like growth factor-1) can enhance the rate of bone formation and synthesis of extracellular matrix in orthopaedics or periodontology. This study aimed to determine the concentration of cytokines within platelet-rich fibrin microstructures and investigate whether there are differences in the different portions of platelet-rich fibrin, which has implications for proper clinical use of platelet-rich fibrin gel. Whole blood was obtained from six New Zealand rabbits (male, 7 to 39 weeks old, weight 2.7-4 kg); it was then centrifuged for preparation of platelet-rich fibrin gels and harvest of plasma. The resultant platelet-rich fibrin gels were used for cytokine determination, histological analyses and scanning electron microscopy. All plasmas obtained were subject to the same cytokine determination assays for the purpose of comparison. Cytokines platelet-derived growth factor-BB and transforming growth factor-β1 formed concentration gradients from high at the red blood cell end of the platelet-rich fibrin gel (p=1.88×10-5) to low at the plasma end (p=0.19). Insulin-like growth factor-1 concentrations were similar at the red blood cell and plasma ends. The porosities of the platelet-rich fibrin samples taken in sequence from the red blood cell end to the plasma end were 6.5% ± 4.9%, 24.8% ± 7.5%, 30.3% ± 8.5%, 41.4% ± 12.3%, and 40.3% ± 11.7%, respectively, showing a gradual decrease in the compactness of the platelet-rich fibrin network. Cytokine concentrations are positively associated with platelet-rich fibrin microstructure and portion in a rabbit model. As platelet-rich fibrin is the main entity currently used in regenerative medicine, assessing cytokine concentration and the most valuable portion of PRF gels is essential and recommended to all physicians.

  19. Three-dimensional structure and cytokine distribution of platelet-rich fibrin

    Directory of Open Access Journals (Sweden)

    Meng-Yi Bai

    Full Text Available OBJECTIVES: Previous reports have revealed that several cytokines (including platelet-derived growth factor-BB, transforming growth factors-β1 and insulin-like growth factor-1 can enhance the rate of bone formation and synthesis of extracellular matrix in orthopaedics or periodontology. This study aimed to determine the concentration of cytokines within platelet-rich fibrin microstructures and investigate whether there are differences in the different portions of platelet-rich fibrin, which has implications for proper clinical use of platelet-rich fibrin gel. METHODS: Whole blood was obtained from six New Zealand rabbits (male, 7 to 39 weeks old, weight 2.7-4 kg; it was then centrifuged for preparation of platelet-rich fibrin gels and harvest of plasma. The resultant platelet-rich fibrin gels were used for cytokine determination, histological analyses and scanning electron microscopy. All plasmas obtained were subject to the same cytokine determination assays for the purpose of comparison. RESULTS: Cytokines platelet-derived growth factor-BB and transforming growth factor-β1 formed concentration gradients from high at the red blood cell end of the platelet-rich fibrin gel (p=1.88×10-5 to low at the plasma end (p=0.19. Insulin-like growth factor-1 concentrations were similar at the red blood cell and plasma ends. The porosities of the platelet-rich fibrin samples taken in sequence from the red blood cell end to the plasma end were 6.5% ± 4.9%, 24.8% ± 7.5%, 30.3% ± 8.5%, 41.4% ± 12.3%, and 40.3% ± 11.7%, respectively, showing a gradual decrease in the compactness of the platelet-rich fibrin network. CONCLUSION: Cytokine concentrations are positively associated with platelet-rich fibrin microstructure and portion in a rabbit model. As platelet-rich fibrin is the main entity currently used in regenerative medicine, assessing cytokine concentration and the most valuable portion of PRF gels is essential and recommended to all physicians.

  20. Mixed-substrate (glycerol tributyrate and fibrin) zymography for simultaneous detection of lipolytic and proteolytic enzymes on a single gel.

    Science.gov (United States)

    Choi, Nack-Shick; Choi, Jong Hyun; Kim, Bo-Hye; Han, Yun-Jon; Kim, Joong Su; Lee, Seung-Goo; Song, Jae Jun

    2009-06-01

    A new zymography method for simultaneous detection of two different enzymatic activities (lipolytic and proteolytic) using a single SDS-containing or native-conformation gel and a mixed-substrate (glycerol tributyrate and fibrin) (MS)(1) gel was developed. After routine electrophoresis, SDS in the gel was removed by treatment with Triton X-100. Gel proteins were electrotransferred to the MS gel. To visualize lipolytic activity, the MS gel was incubated at 37 degrees C (for 6 or 24 h) until clear bands against an opaque background were observed. To detect proteolytic activity, the same MS gel was stained with Coomassie brilliant blue. Using this method, we show that six lipolytic enzymes from Staphylococcus pasteuri NJ-1 and four proteolytic enzymes from two Bacillus strains, B. licheniformis DJ-2 and B. licheniformis NJ-5, isolated from soil, can be simultaneously detected.

  1. Evaluation of gold nanotracers to track adipose-derived stem cells in a PEGylated fibrin gel for dermal tissue engineering applications

    Directory of Open Access Journals (Sweden)

    Chung E

    2013-01-01

    Full Text Available Eunna Chung,1 Seung Yun Nam,1,2 Laura M Ricles,1 Stanislav Y Emelianov,1,2 Laura J Suggs11Department of Biomedical Engineering, 2Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, USAAbstract: Evaluating the regenerative capacity of a tissue-engineered device in a noninvasive and synchronous manner is critical to determining the mechanisms for success in clinical applications. In particular, directly tracking implanted cells in a three-dimensional (3D scaffold is desirable in that it enables the monitoring of cellular activity in a specific and localized manner. The authors' group has previously demonstrated that the PEGylation of fibrin results in a 3D scaffold that supports morphologic and phenotypic changes in mesenchymal stem cells that may be advantageous in wound healing applications. Recently, the authors have evaluated adipose-derived stem cells (ASCs as a mesenchymal cell source to regenerate skin and blood vessels due to their potential for proliferation, differentiation, and production of growth factors. However, tracking and monitoring ASCs in a 3D scaffold, such as a PEGylated fibrin gel, have not yet been fully investigated. In the current paper, nanoscale gold spheres (20 nm as cell tracers for ASCs cultured in a PEGylated fibrin gel were evaluated. An advanced dual-imaging modality combining ultrasound and photoacoustic imaging was utilized to monitor rat ASCs over time. The ASCs took up gold nanotracers and could be detected up to day 16 with high sensitivity using photoacoustic imaging. There were no detrimental effects on ASC morphology, network formation, proliferation, and protein expression/secretion (ie, smooth muscle α-actin, vascular endothelial growth factor, matrix metalloproteinase-2, and matrix metalloproteinase-9 associated with gold nanotracers. Therefore, utilization of gold nanotracers can be an effective strategy to monitor the regenerative process of a stem cell

  2. Role of plasma-rich fibrin in oral surgery

    Directory of Open Access Journals (Sweden)

    K Retna Kumar

    2016-01-01

    Full Text Available Platelet-rich fibrin (PRF is a fibrin meshwork, in which platelet cytokines, growth factors, and cells are entrapped and discharged after a period and can serve as a resorbable film. PRF is the next generation of platelet concentrates equipped to improve arrangement without biochemical blood handling; PRF is an evolution of the fibrin adhesive, which is widely used in the oral surgery. The guidelines of this innovation depend on concentrating platelets and growth factors in a plasma medium, and initiating them in a fibrin gel, keeping in mind the end goal to enhance the healing of wounds. Maxillary bone loss requires numerous regenerative techniques: as a supplement to the procedures of tissue regeneration, a platelet concentrate called PRF was tested for the 1st time in France by Dr. Choukroun. This article enriches the benefits and role of plasma-rich fibrin in oral surgery. Platelet-concentrate fibrin is an evolution of the fibrin glue, which is widely used in the oral surgery.

  3. Characterization of Leukocyte-platelet Rich Fibrin, A Novel Biomaterial

    OpenAIRE

    Madurantakam, Parthasarathy; Yoganarasimha, Suyog; Hasan, Fadi K.

    2015-01-01

    Autologous platelet concentrates represent promising innovative tools in the field of regenerative medicine and have been extensively used in oral surgery. Unlike platelet rich plasma (PRP) that is a gel or a suspension, Leukocyte-Platelet Rich Fibrin (L-PRF) is a solid 3D fibrin membrane generated chair-side from whole blood containing no anti-coagulant. The membrane has a dense three dimensional fibrin matrix with enriched platelets and abundant growth factors. L-PRF is a popular adjunct in...

  4. Nano-fibrin stabilized CaSO4 crystals incorporated injectable chitin composite hydrogel for enhanced angiogenesis & osteogenesis.

    Science.gov (United States)

    Arun Kumar, R; Sivashanmugam, A; Deepthi, S; Bumgardner, Joel D; Nair, Shantikumar V; Jayakumar, R

    2016-04-20

    Calcium sulfate (CaSO4), an excellent biodegradable bone forming agent that is an ideal choice as additive in gels, however, its disadvantage being poor gel rheology and angiogenesis. Here, we have synthesized chitin-CaSO4-nano-fibrin based injectable gel system which shows improved rheology and angiogenic potential. Rheological studies showed that the composite gel was a shear thinning gel with elastic modulus of 15.4±0.275kPa; a 1.67 fold increase over chitin control. SEM and XRD analyses revealed the effect of nano-fibrin (nFibrin) in transforming CaSO4 crystal shape from needle to hexagonal. It also masked the retarding effect of CaSO4 towards in vitro early cell attachment and angiogenesis using rabbit adipose derived mesenchymal stem cells (rASCs) and HUVECs, respectively. rASCs osteogenesis was confirmed by spectrophotometric endpoint assay, which showed 6-fold early increase in alkaline phosphatase levels and immuno-cytochemistry analysis. These in vitro results highlight the potential of injectable chitin-CaSO4-nFibrin gel for osteo-regeneration via enhanced angiogenesis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Effects of annulus defects and implantation of poly(lactic-co-glycolic acid) (PLGA)/fibrin gel scaffolds on nerves ingrowth in a rabbit model of annular injury disc degeneration.

    Science.gov (United States)

    Xin, Long; Xu, Weixing; Yu, Leijun; Fan, Shunwu; Wang, Wei; Yu, Fang; Wang, Zhenbin

    2017-05-12

    Growth of nerve fibers has been shown to occur in a rabbit model of intravertebral disc degeneration (IVD) induced by needle puncture. As nerve growth may underlie the process of chronic pain in humans affected by disc degeneration, we sought to investigate the factors underlying nerve ingrowth in a minimally invasive annulotomy rabbit model of IVD by comparing the effects of empty disc defects with those of defects filled with poly(lactic-co-glycolic acid)/fibrin gel (PLGA) plugs. New Zealand white rabbits (n = 24) received annular injuries at three lumbar levels (L3/4, L4/5, and L5/6). The discs were randomly assigned to four groups: (a) annular defect (1.8-mm diameter; 4-mm depth) by mini-trephine, (b) annular defect implanted with a PLGA scaffold containing a fibrin gel, (c) annular puncture by a 16G needle (5-mm depth), and (d) uninjured L2/3 disc (control). Disc degeneration was evaluated by radiography, MRI, histology, real-time PCR, and analysis of proteoglycan (PG) content. Nerve ingrowth into the discs was assessed by immunostaining with the nerve marker protein gene product 9.5. Injured discs showed a progressive disc space narrowing with significant disc degeneration and proteoglycan loss, as confirmed by imaging results, molecular and compositional analysis, and histological examinations. In 16G punctured discs, nerve ingrowth was observed on the surface of scar tissue. In annular defects, nerve fibers were found to be distributed along small fissures within the fibrocartilaginous-like tissue that filled the AF. In discs filled with PLGA/ fibrin gel, more nerve fibers were observed growing deeper into the inner AF along the open annular track.  In addition, innervations scores showed significantly higher than those of punctured discs and empty defects. A limited vascular proliferation was found in the injured sites and regenerated tissues. Nerve ingrowth was significantly higher in PLGA/fibrin-filled discs than in empty defects. Possible

  6. Engineering fibrin hydrogels to promote the wound healing potential of mesenchymal stem cell spheroids.

    Science.gov (United States)

    Murphy, Kaitlin C; Whitehead, Jacklyn; Zhou, Dejie; Ho, Steve S; Leach, J Kent

    2017-12-01

    Mesenchymal stem cells (MSCs) secrete endogenous factors such as vascular endothelial growth factor (VEGF) and prostaglandin E2 (PGE 2 ) that promote angiogenesis, modulate the inflammatory microenvironment, and stimulate wound repair, and MSC spheroids secrete more trophic factors than dissociated, individual MSCs. Compared to injection of cells alone, transplantation of MSCs in a biomaterial can enhance their wound healing potential by localizing cells at the defect site and upregulating trophic factor secretion. To capitalize on the therapeutic potential of spheroids, we engineered a fibrin gel delivery vehicle to simultaneously enhance the proangiogenic and anti-inflammatory potential of entrapped human MSC spheroids. We used multifactorial statistical analysis to determine the interaction between four input variables derived from fibrin gel synthesis on four output variables (gel stiffness, gel contraction, and secretion of VEGF and PGE 2 ). Manipulation of the four input variables tuned fibrin gel biophysical properties to promote the simultaneous secretion of VEGF and PGE 2 by entrapped MSC spheroids while maintaining overall gel integrity. MSC spheroids in stiffer gels secreted the most VEGF, while PGE 2 secretion was highest in more compliant gels. Simultaneous VEGF and PGE 2 secretion was greatest using hydrogels with intermediate mechanical properties, as small increases in stiffness increased VEGF secretion while maintaining PGE 2 secretion by entrapped spheroids. The fibrin gel formulation predicted to simultaneously increase VEGF and PGE 2 secretion stimulated endothelial cell proliferation, enhanced macrophage polarization, and promoted angiogenesis when used to treat a wounded three-dimensional human skin equivalent. These data demonstrate that a statistical approach is an effective strategy to formulate fibrin gel formulations that enhance the wound healing potential of human MSCs. Mesenchymal stem cells (MSCs) are under investigation for wound

  7. Reduction of Pulmonary Air Leaks with a Combination of Polyglycolic Acid Sheet and Alginate Gel in Rats

    Directory of Open Access Journals (Sweden)

    Mari Matoba

    2018-01-01

    Full Text Available Postoperative air leaks remain a major cause of morbidity after lung resection. This study evaluated the effect of a combination of polyglycolic acid (PGA sheet and alginate gel on pulmonary air leaks in rats. Four pulmonary sealing materials were evaluated in lung injury: fibrin glue, combination of PGA sheet and fibrin glue, alginate gel, and combination of PGA sheet and alginate gel. With the airway pressure maintained at 20 cmH2O, a 2 mm deep puncture wound was created on the lung surface using a needle. Lowering the airway pressure to 5 cmH2O, each sealing material was applied. The lowest airway pressure that broke the seal was measured. The seal-breaking pressure in each experimental group was fibrin, 10.4±6.8 cmH2O; PGA + fibrin, 13.5±6.5 cmH2O; alginate gel, 10.3±4.9 cmH2O; and PGA + alginate, 35.8±11.9 cmH2O, respectively. The seal-breaking pressure was significantly greater in the PGA + alginate gel group than in the other groups (p<0.01. There were no significant differences among the other three groups. Alginate gel combined with a PGA sheet is a promising alternative to fibrin glue as a safe and low-cost material for air leak prevention in pulmonary surgery.

  8. Chronic Intraocular Inflammation as a Risk Factor for XEN Gel Stent Occlusion: A Case of Microscopic Examination of a Fibrin-obstructed XEN Stent.

    Science.gov (United States)

    Gillmann, Kevin; Mansouri, Kaweh; Bravetti, Giorgio Enrico; Mermoud, André

    2018-06-05

    In recent years microinvasive glaucoma surgery (MIGS) has risen in popularity. Amongst MIGS options is the XEN gel stent (Allergan Plc, Dublin, Ireland), a 45▒μm wide ab-interno microstent. It has proven effective in lowering IOP with low complication rates. However, XEN gel stents can become obstructed and cause postoperative rise in IOP. The causes and predicting factors for such obstructions still requires further research. We describe the case of a 69-year old male patient, with traumatic glaucoma and chronic intraocular inflammation demonstrated by laser flare photometry, following childhood trauma and anterior segment surgery. Uncontrollable IOP despite maximal antiglaucomatous therapy was managed with XEN-augmented Baerveldt surgery. Despite good initial filtration and IOP control, the XEN stent became obstructed and was surgically replaced. After a month, the new stent became obstructed and was replaced by a thicker-lumened Baerveldt tube. This restored good filtration, and adequate IOP was maintained post-operatively. Microscopic examination of the obstructed XEN stent showed a dense fibrin plug. This case report shows that fibrin formation could be an important factor in XEN gel stent obstruction, even in initially successfully filtering stents. The association of fibrinogenesis and intraocular inflammation could add a note of caution to the use of XEN gel stents in complicated cataract surgery, or advocate for aggressive anti-inflammatory treatments post-operatively. This could lead to a refinement in success predictors and better patient selection for XEN surgery. Finally, this could open the way to new management options for persistent obstructions, including pharmaceutical fibrinolysis.

  9. Composition of fibrin glues significantly influences axial vascularization and degradation in isolation chamber model.

    Science.gov (United States)

    Arkudas, Andreas; Pryymachuk, Galyna; Hoereth, Tobias; Beier, Justus P; Polykandriotis, Elias; Bleiziffer, Oliver; Gulle, Heinz; Horch, Raymund E; Kneser, Ulrich

    2012-07-01

    In this study, different fibrin sealants with varying concentrations of the fibrin components were evaluated in terms of matrix degradation and vascularization in the arteriovenous loop (AVL) model of the rat. An AVL was placed in a Teflon isolation chamber filled with 500 μl fibrin gel. The matrix was composed of commercially available fibrin gels, namely Beriplast (Behring GmbH, Marburg, Germany) (group A), Evicel (Omrix Biopharmaceuticals S.A., Somerville, New Jersey, USA) (group B), Tisseel VH S/D (Baxter, Vienna, Austria) with a thrombin concentration of 4 IU/ml and a fibrinogen concentration of 80 mg/ml [Tisseel S F80 (Baxter), group C] and with an fibrinogen concentration of 20 mg/ml [Tisseel S F20 (Baxter), group D]. After 2 and 4 weeks, five constructs per group and time point were investigated using micro-computed tomography, and histological and morphometrical analysis techniques. The aprotinin, factor XIII and thrombin concentration did not affect the degree of clot degradation. An inverse relationship was found between fibrin matrix degradation and sprouting of blood vessels. By reducing the fibrinogen concentration in group D, a significantly decreased construct weight and an increased generation of vascularized connective tissue were detected. There was an inverse relationship between matrix degradation and vascularization detectable. Fibrinogen as the major matrix component showed a significant impact on the matrix properties. Alteration of fibrin gel properties might optimize formation of blood vessels.

  10. Fibrin Gels Exhibit Improved Biological, Structural, and Mechanical Properties Compared with Collagen Gels in Cell-Based Tendon Tissue-Engineered Constructs

    Science.gov (United States)

    Dyment, Nathaniel A.; Lu, Yinhui; Rao, Marepalli; Shearn, Jason T.; Rowe, David W.; Kadler, Karl E.; Butler, David L.

    2015-01-01

    The prevalence of tendon and ligament injuries and inadequacies of current treatments is driving the need for alternative strategies such as tissue engineering. Fibrin and collagen biopolymers have been popular materials for creating tissue-engineered constructs (TECs), as they exhibit advantages of biocompatibility and flexibility in construct design. Unfortunately, a few studies have directly compared these materials for tendon and ligament applications. Therefore, this study aims at determining how collagen versus fibrin hydrogels affect the biological, structural, and mechanical properties of TECs during formation in vitro. Our findings show that tendon and ligament progenitor cells seeded in fibrin constructs exhibit improved tenogenic gene expression patterns compared with their collagen-based counterparts for approximately 14 days in culture. Fibrin-based constructs also exhibit improved cell-derived collagen alignment, increased linear modulus (2.2-fold greater) compared with collagen-based constructs. Cyclic tensile loading, which promotes the maturation of tendon constructs in a previous work, exhibits a material-dependent effect in this study. Fibrin constructs show trending reductions in mechanical, biological, and structural properties, whereas collagen constructs only show improved tenogenic expression in the presence of mechanical stimulation. These findings highlight that components of the mechanical stimulus (e.g., strain amplitude or time of initiation) need to be tailored to the material and cell type. Given the improvements in tenogenic expression, extracellular matrix organization, and material properties during static culture, in vitro findings presented here suggest that fibrin-based constructs may be a more suitable alternative to collagen-based constructs for tissue-engineered tendon/ligament repair. PMID:25266738

  11. Characterization of Leukocyte-platelet Rich Fibrin, A Novel Biomaterial.

    Science.gov (United States)

    Madurantakam, Parthasarathy; Yoganarasimha, Suyog; Hasan, Fadi K

    2015-09-29

    Autologous platelet concentrates represent promising innovative tools in the field of regenerative medicine and have been extensively used in oral surgery. Unlike platelet rich plasma (PRP) that is a gel or a suspension, Leukocyte-Platelet Rich Fibrin (L-PRF) is a solid 3D fibrin membrane generated chair-side from whole blood containing no anti-coagulant. The membrane has a dense three dimensional fibrin matrix with enriched platelets and abundant growth factors. L-PRF is a popular adjunct in surgeries because of its superior handling characteristics as well as its suturability to the wound bed. The goal of the study is to demonstrate generation as well as provide detailed characterization of relevant properties of L-PRF that underlie its clinical success.

  12. Alginate nanobeads interspersed fibrin network as in situ forming hydrogel for soft tissue engineering.

    Science.gov (United States)

    Deepthi, S; Jayakumar, R

    2018-06-01

    Hydrogels are a class of materials that has the property of injectability and in situ gel formation. This property of hydrogels is manipulated in this study to develop a biomimetic bioresorbable injectable system of alginate nanobeads interspersed in fibrin network. Alginate nanobeads developed by calcium cross-linking yielded a size of 200-500 nm. The alginate nanobeads fibrin hydrogel was formed using dual syringe apparatus. Characterization of the in situ injectable hydrogel was done by SEM, FTIR and Rheometer. The developed hydrogel showed mechanical strength of 19 kPa which provides the suitable compliance for soft tissue engineering. Cytocompatibility studies using human umbilical cord blood derived mesenchymal stem cells showed good attachment, proliferation and infiltration within the hydrogel similar to fibrin gel. The developed in situ forming hydrogel could be a suitable delivery carrier of stem cells for soft tissue regeneration.

  13. The hydraulic permeability of blood clots as a function of fibrin and platelet density.

    Science.gov (United States)

    Wufsus, A R; Macera, N E; Neeves, K B

    2013-04-16

    Interstitial fluid flow within blood clots is a biophysical mechanism that regulates clot growth and dissolution. Assuming that a clot can be modeled as a porous medium, the physical property that dictates interstitial fluid flow is the hydraulic permeability. The objective of this study was to bound the possible values of the hydraulic permeability in clots formed in vivo and present relationships that can be used to estimate clot permeability as a function of composition. A series of clots with known densities of fibrin and platelets, the two major components of a clot, were formed under static conditions. The permeability was calculated by measuring the interstitial fluid velocity through the clots at a constant pressure gradient. Fibrin gels formed with a fiber volume fraction of 0.02-0.54 had permeabilities of 1.2 × 10(-1)-1.5 × 10(-4)μm(2). Platelet-rich clots with a platelet volume fraction of 0.01-0.61 and a fibrin volume fraction of 0.03 had permeabilities over a range of 1.1 × 10(-2)-1.5 × 10(-5)μm(2). The permeability of fibrin gels and of clots with platelet volume fraction of platelet volume fraction of >0.2 were modeled as a Brinkman medium of coarse solids (platelets) embedded in a mesh of fine fibers (fibrin). Our data suggest that the permeability of clots formed in vivo can vary by up to five orders of magnitude, with pore sizes that range from 4 to 350 nm. These findings have important implications for the transport of coagulation zymogens/enzymes in the interstitial spaces during clot formation, as well as the design of fibrinolytic drug delivery strategies. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  14. Alginate nanobeads interspersed fibrin network as in situ forming hydrogel for soft tissue engineering

    Directory of Open Access Journals (Sweden)

    S. Deepthi

    2018-06-01

    Full Text Available Hydrogels are a class of materials that has the property of injectability and in situ gel formation. This property of hydrogels is manipulated in this study to develop a biomimetic bioresorbable injectable system of alginate nanobeads interspersed in fibrin network. Alginate nanobeads developed by calcium cross-linking yielded a size of 200–500 nm. The alginate nanobeads fibrin hydrogel was formed using dual syringe apparatus. Characterization of the in situ injectable hydrogel was done by SEM, FTIR and Rheometer. The developed hydrogel showed mechanical strength of 19 kPa which provides the suitable compliance for soft tissue engineering. Cytocompatibility studies using human umbilical cord blood derived mesenchymal stem cells showed good attachment, proliferation and infiltration within the hydrogel similar to fibrin gel. The developed in situ forming hydrogel could be a suitable delivery carrier of stem cells for soft tissue regeneration.

  15. Platelet-rich fibrin matrix improves wound angiogenesis via inducing endothelial cell proliferation.

    Science.gov (United States)

    Roy, Sashwati; Driggs, Jason; Elgharably, Haytham; Biswas, Sabyasachi; Findley, Muna; Khanna, Savita; Gnyawali, Urmila; Bergdall, Valerie K; Sen, Chandan K

    2011-11-01

    The economic, social, and public health burden of chronic ulcers and other compromised wounds is enormous and rapidly increasing with the aging population. The growth factors derived from platelets play an important role in tissue remodeling including neovascularization. Platelet-rich plasma (PRP) has been utilized and studied for the last four decades. Platelet gel and fibrin sealant, derived from PRP mixed with thrombin and calcium chloride, have been exogenously applied to tissues to promote wound healing, bone growth, hemostasis, and tissue sealing. In this study, we first characterized recovery and viability of as well as growth factor release from platelets in a novel preparation of platelet gel and fibrin matrix, namely platelet-rich fibrin matrix (PRFM). Next, the effect of PRFM application in a delayed model of ischemic wound angiogenesis was investigated. The study, for the first time, shows the kinetics of the viability of platelet-embedded fibrin matrix. A slow and steady release of growth factors from PRFM was observed. The vascular endothelial growth factor released from PRFM was primarily responsible for endothelial mitogenic response via extracellular signal-regulated protein kinase activation pathway. Finally, this preparation of PRFM effectively induced endothelial cell proliferation and improved wound angiogenesis in chronic wounds, providing evidence of probable mechanisms of action of PRFM in healing of chronic ulcers. 2011 by the Wound Healing Society.

  16. A review of fibrin and fibrin composites for bone tissue engineering.

    Science.gov (United States)

    Noori, Alireza; Ashrafi, Seyed Jamal; Vaez-Ghaemi, Roza; Hatamian-Zaremi, Ashraf; Webster, Thomas J

    2017-01-01

    Tissue engineering has emerged as a new treatment approach for bone repair and regeneration seeking to address limitations associated with current therapies, such as autologous bone grafting. While many bone tissue engineering approaches have traditionally focused on synthetic materials (such as polymers or hydrogels), there has been a lot of excitement surrounding the use of natural materials due to their biologically inspired properties. Fibrin is a natural scaffold formed following tissue injury that initiates hemostasis and provides the initial matrix useful for cell adhesion, migration, proliferation, and differentiation. Fibrin has captured the interest of bone tissue engineers due to its excellent biocompatibility, controllable biodegradability, and ability to deliver cells and biomolecules. Fibrin is particularly appealing because its precursors, fibrinogen, and thrombin, which can be derived from the patient's own blood, enable the fabrication of completely autologous scaffolds. In this article, we highlight the unique properties of fibrin as a scaffolding material to treat bone defects. Moreover, we emphasize its role in bone tissue engineering nanocomposites where approaches further emulate the natural nanostructured features of bone when using fibrin and other nanomaterials. We also review the preparation methods of fibrin glue and then discuss a wide range of fibrin applications in bone tissue engineering. These include the delivery of cells and/or biomolecules to a defect site, distributing cells, and/or growth factors throughout other pre-formed scaffolds and enhancing the physical as well as biological properties of other biomaterials. Thoughts on the future direction of fibrin research for bone tissue engineering are also presented. In the future, the development of fibrin precursors as recombinant proteins will solve problems associated with using multiple or single-donor fibrin glue, and the combination of nanomaterials that allow for the

  17. A review of fibrin and fibrin composites for bone tissue engineering

    Directory of Open Access Journals (Sweden)

    Noori A

    2017-07-01

    Full Text Available Alireza Noori,1 Seyed Jamal Ashrafi,2 Roza Vaez-Ghaemi,3 Ashraf Hatamian-Zaremi,4 Thomas J Webster5 1Department of Tissue Engineering and Applied Cell Sciences, Faculty of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, 2School of Medicine, Shahroud University of Medical Sciences, Shahroud, Iran; 3Department of Chemical and Biological Engineering, Faculty of Biomedical Engineering, The University of British Columbia, Vancouver, BC, Canada; 4Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran; 5Department of Chemical Engineering, Northeastern University, Boston, MA, USA Abstract: Tissue engineering has emerged as a new treatment approach for bone repair and regeneration seeking to address limitations associated with current therapies, such as autologous bone grafting. While many bone tissue engineering approaches have traditionally focused on synthetic materials (such as polymers or hydrogels, there has been a lot of excitement surrounding the use of natural materials due to their biologically inspired properties. Fibrin is a natural scaffold formed following tissue injury that initiates hemostasis and provides the initial matrix useful for cell adhesion, migration, proliferation, and differentiation. Fibrin has captured the interest of bone tissue engineers due to its excellent biocompatibility, controllable biodegradability, and ability to deliver cells and biomolecules. Fibrin is particularly appealing because its precursors, fibrinogen, and thrombin, which can be derived from the patient’s own blood, enable the fabrication of completely autologous scaffolds. In this article, we highlight the unique properties of fibrin as a scaffolding material to treat bone defects. Moreover, we emphasize its role in bone tissue engineering nanocomposites where approaches further emulate the natural nanostructured features of bone when using fibrin and other nanomaterials. We also review the

  18. Culture on fibrin matrices maintains the colony-forming capacity and osteoblastic differentiation of mesenchymal stem cells

    International Nuclear Information System (INIS)

    Colley, Helen; McArthur, Sally L; Stolzing, Alexandra; Scutt, Andy

    2012-01-01

    Mesenchymal stem cells (MSC) are multipotent cells capable of differentiating into a number of mesenchymal tissues including bone, cartilage, and tendon. Low numbers in vivo means exponential growth is needed in culture to enable therapeutic applications. MSC can expand rapidly in culture but usually lose their extensive capacity for differentiation that makes them therapeutically attractive. To try and maintain their capacity for differentiation and expansion in vitro, we cultured MSC on fibrin gels of different concentrations to create more physiological growth conditions for the cells. The cells were then re-plated onto tissue culture plastic and analysed. The cells that had been pre-cultured for seven days on fibrin, proliferated and maintained their differential potential to the osteogenic lineage better than tissue culture plastic expanded MSC. A concentration relationship between colony number and fibrin concentration was seen with decreasing numbers as fibrin concentration increased. These data support the concept that substrate signals significantly influence MSC growth and differentiation and that growth on a fibrin matrix could be used to maintain a stem cell phenotype during MSC expansion. (paper)

  19. Monitoring sinew contraction during formation of tissue-engineered fibrin-based ligament constructs.

    Science.gov (United States)

    Paxton, Jennifer Z; Wudebwe, Uchena N G; Wang, Anqi; Woods, Daniel; Grover, Liam M

    2012-08-01

    The ability to study the gross morphological changes occurring during tissue formation is vital to producing tissue-engineered structures of clinically relevant dimensions in vitro. Here, we have used nondestructive methods of digital imaging and optical coherence tomography to monitor the early-stage formation and subsequent maturation of fibrin-based tissue-engineered ligament constructs. In addition, the effect of supplementation with essential promoters of collagen synthesis, ascorbic acid (AA) and proline (P), has been assessed. Contraction of the cell-seeded fibrin gel occurs unevenly within the first 5 days of culture around two fixed anchor points before forming a longitudinal ligament-like construct. AA+P supplementation accelerates gel contraction in the maturation phase of development, producing ligament-like constructs with a higher collagen content and distinct morphology to that of unsupplemented constructs. These studies highlight the importance of being able to control the methods of tissue formation and maturation in vitro to enable the production of tissue-engineered constructs with suitable replacement tissue characteristics for repair of clinical soft-tissue injuries.

  20. FIBRIN GLUE DAN APLIKASINYA

    Directory of Open Access Journals (Sweden)

    Agi Harliani S

    2015-08-01

    Full Text Available Fibrin Tissue Adhesive (FTA, Fibrin Sealant (FS or Fibrin Glue (FG are names given to a group of product that lead to the formation of fibrin clot at the site of application. Fibrin Glue represents a new revolution for local haemostatic, which produced by based on the understanding about blood coagulation process. The mechanism of FG mimics the last stage of blood coagulation process. Haemophilia, is a congenital inherited bleeding disorder, characterized by repeated bleeding episodes. The basic pathology is deficiency of factor VIII (hemophilia A or factor IX (hemophilia B. At bleeding episodes, hemophilia patients need replacement therapy. Hemophilia patients need transfusion of cryoprecipitate, Fresh Frozen Plasma (FFP or factor concentrate as replacement therapy. Oral surgery, dental extraction, circumcision, and orthopedic operations are the most important indications for fibrin glue in hemophilia care. As haemostatic local, FG minimizes bleeding, reducing the need of transfusion or factor concentrate, reducing the complication of transfusion, hospitalization and cost.

  1. A PEGylated Fibrin-Based Wound Dressing with Antimicrobial and Angiogenic Activity

    Science.gov (United States)

    2011-04-13

    activity SSD–CSM particles were impregnated in polyethylene glycol (PEGylated) fibrin gels. In vitro drug release studies showed that a burst release of...promote revascularization. Silver sulfadiazine (SSD) is a broad spectrum antimicrobial agent that controls yeasts, molds, other types of fungi , and...site is currently thought to be a crucial early event in the tissue regeneration process [23]. We have recently shown that a polyethylene glycol-based

  2. Fibrin- versus Plasma-Gel Scaffolds - und der Einfluss von TGF-ß und bFGF auf Myofibroblasten und die Gewebeneogenese

    OpenAIRE

    Dietrich, Maren

    2015-01-01

    One central aspect in tissue engineering is the scaffold. Due to its properties and the direct contact to cells, it strongly influences the development of the tissue engineered construct. Especially attractive are autologous materials, like fibrin. To optimize autologous PFP- and fibrin-scaffolds this work compared the basic materials platelet free plasma (PFP), platelet poor plasma (PPP), and platelet rich plasma (PRP) as autologous materials for scaffold production. Three differently concen...

  3. Fibrin structural and diffusional analysis suggests that fibers are permeable to solute transport.

    Science.gov (United States)

    Leonidakis, Kimon Alexandros; Bhattacharya, Pinaki; Patterson, Jennifer; Vos, Bart E; Koenderink, Gijsje H; Vermant, Jan; Lambrechts, Dennis; Roeffaers, Maarten; Van Oosterwyck, Hans

    2017-01-01

    Fibrin hydrogels are promising carrier materials in tissue engineering. They are biocompatible and easy to prepare, they can bind growth factors and they can be prepared from a patient's own blood. While fibrin structure and mechanics have been extensively studied, not much is known about the relation between structure and diffusivity of solutes within the network. This is particularly relevant for solutes with a size similar to that of growth factors. A novel methodological approach has been used in this study to retrieve quantitative structural characteristics of fibrin hydrogels, by combining two complementary techniques, namely confocal fluorescence microscopy with a fiber extraction algorithm and turbidity measurements. Bulk rheological measurements were conducted to determine the impact of fibrin hydrogel structure on mechanical properties. From these measurements it can be concluded that variations in the fibrin hydrogel structure have a large impact on the rheological response of the hydrogels (up to two orders of magnitude difference in storage modulus) but only a moderate influence on the diffusivity of dextran solutes (up to 25% difference). By analyzing the diffusivity measurements by means of the Ogston diffusion model we further provide evidence that individual fibrin fibers can be semi-permeable to solute transport, depending on the average distance between individual protofibrils. This can be important for reducing mass transport limitations, for modulating fibrinolysis and for growth factor binding, which are all relevant for tissue engineering. Fibrin is a natural biopolymer that has drawn much interest as a biomimetic carrier in tissue engineering applications. We hereby use a novel combined approach for the structural characterization of fibrin networks based on optical microscopy and light scattering methods that can also be applied to other fibrillar hydrogels, like collagen. Furthermore, our findings on the relation between solute transport

  4. Fibronectin alters the rate of formation and structure of the fibrin matrix.

    Science.gov (United States)

    Ramanathan, Anand; Karuri, Nancy

    2014-01-10

    Plasma fibronectin is a vital component of the fibrin clot; however its role on clot structure is not clearly understood. The goal of this study was to examine the influence of fibronectin on the kinetics of formation, structural characteristics and composition of reconstituted fibrin clots or fibrin matrices. Fibrin matrices were formed by adding thrombin to 1, 2 or 4 mg/ml fibrinogen supplemented with 0-0.4 mg/ml fibronectin. The rate of fibrin matrix formation was then monitored by measuring light absorbance properties at different time points. Confocal microscopy of fluorescein conjugated fibrinogen was used to visualize the structural characteristics of fibrin matrices. The amount of fibronectin in fibrin matrices was determined through electrophoresis and immunoblotting of solubilized matrices. Fibronectin concentration positively correlated with the initial rate of fibrin matrix formation and with steady state light absorbance values of fibrin matrices. An increase in fibronectin concentration resulted in thinner and denser fibers in the fibrin matrices. Electrophoresis and immunoblotting showed that fibronectin was covalently and non-covalently bound to fibrin matrices and in the form of high molecular weight multimers. The formation of fibronectin multimers was attributed to cross-linking of fibronectin by trace amounts Factor XIIIa. These findings are novel because they link results from light absorbance studies to microcopy analyses and demonstrate an influence of fibronectin on fibrin matrix structural characteristics. This data is important in developing therapies that destabilize fibrin clots. Copyright © 2014. Published by Elsevier Inc.

  5. Fibrinogen and fibrin.

    Science.gov (United States)

    Weisel, John W

    2005-01-01

    Fibrinogen is a large, complex, fibrous glycoprotein with three pairs of polypeptide chains linked together by 29 disulfide bonds. It is 45 nm in length, with globular domains at each end and in the middle connected by alpha-helical coiled-coil rods. Both strongly and weakly bound calcium ions are important for maintenance of fibrinogen's structure and functions. The fibrinopeptides, which are in the central region, are cleaved by thrombin to convert soluble fibrinogen to insoluble fibrin polymer, via intermolecular interactions of the "knobs" exposed by fibrinopeptide removal with "holes" always exposed at the ends of the molecules. Fibrin monomers polymerize via these specific and tightly controlled binding interactions to make half-staggered oligomers that lengthen into protofibrils. The protofibrils aggregate laterally to make fibers, which then branch to yield a three-dimensional network-the fibrin clot-essential for hemostasis. X-ray crystallographic structures of portions of fibrinogen have provided some details on how these interactions occur. Finally, the transglutaminase, Factor XIIIa, covalently binds specific glutamine residues in one fibrin molecule to lysine residues in another via isopeptide bonds, stabilizing the clot against mechanical, chemical, and proteolytic insults. The gene regulation of fibrinogen synthesis and its assembly into multichain complexes proceed via a series of well-defined steps. Alternate splicing of two of the chains yields common variant molecular isoforms. The mechanical properties of clots, which can be quite variable, are essential to fibrin's functions in hemostasis and wound healing. The fibrinolytic system, with the zymogen plasminogen binding to fibrin together with tissue-type plasminogen activator to promote activation to the active enzyme plasmin, results in digestion of fibrin at specific lysine residues. Fibrin(ogen) also specifically binds a variety of other proteins, including fibronectin, albumin

  6. Construction of tissue-engineered small-diameter vascular grafts in fibrin scaffolds in 30 days.

    Science.gov (United States)

    Gui, Liqiong; Boyle, Michael J; Kamin, Yishai M; Huang, Angela H; Starcher, Barry C; Miller, Cheryl A; Vishnevetsky, Michael J; Niklason, Laura E

    2014-05-01

    Tissue-engineered small-diameter vascular grafts have been developed as a promising alternative to native veins or arteries for replacement therapy. However, there is still a crucial need to improve the current approaches to render the tissue-engineered blood vessels more favorable for clinical applications. A completely biological blood vessel (3-mm inner diameter) was constructed by culturing a 50:50 mixture of bovine smooth muscle cells (SMCs) with neonatal human dermal fibroblasts in fibrin gels. After 30 days of culture under pulsatile stretching, the engineered blood vessels demonstrated an average burst pressure of 913.3±150.1 mmHg (n=6), a suture retention (53.3±15.4 g) that is suitable for implantation, and a compliance (3.1%±2.5% per 100 mmHg) that is comparable to native vessels. These engineered grafts contained circumferentially aligned collagen fibers, microfibrils and elastic fibers, and differentiated SMCs, mimicking a native artery. These promising mechanical and biochemical properties were achieved in a very short culture time of 30 days, suggesting the potential of co-culturing SMCs with fibroblasts in fibrin gels to generate functional small-diameter vascular grafts for vascular reconstruction surgery.

  7. Tensile strength of biological fibrin sealants: a comparative study.

    Science.gov (United States)

    Lacaze, Laurence; Le Dem, Nicolas; Bubenheim, Michael; Tsilividis, Basile; Mezghani, Julien; Schwartz, Lilian; Francois, Arnaud; Ertaud, Jean Yves; Bagot d'Arc, Maurice; Scotté, Michel

    2012-08-01

    Fibrin sealants are commonly used in liver surgery, although their effectiveness in routine clinical practice remains controversial. Individual sealant characteristics are based on hemostatic effects and adhesion properties that can be experimentally measured using the 'rat skin test' or the 'pig skin test'. This study used a more relevant and realistic experimental canine model to compare the differences in the adhesive properties of four fibrin sealants in hepatectomy: Tisseel/Tissucol, Tachosil, Quixil, and Beriplast. A partial hepatectomy was performed in beagle dogs under general anesthesia to obtain liver cross-sections. Fibrin sealants were allocated to dog livers using a Youden square design. The tensile strength measurement was performed using a traction system to measure the rupture stress point of a small wooden cylinder bonded to the liver cross-section. Significantly greater adhesion properties were observed with Tisseel/Tissucol compared with Quixil or Beriplast (P = 0.002 and 0.001, respectively). Similarly, Tachosil demonstrated significantly greater adhesive properties compared with Beriplast (P = 0.009) or Quixil (P = 0.014). No significant differences were observed between Tisseel/Tissucol and Tachosil or between Beriplast and Quixil. The results of this comparative study demonstrate that different fibrin sealants exhibit different adhesive properties. Tisseel/Tissucol and Tachosil provided greatest adhesion to liver cross-section in our canine model of hepatectomy. These results may enable the optimal choice of fibrin sealants for this procedure in clinical practice. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Tumour imaging by the detection of fibrin clots in tumour stroma using an anti-fibrin Fab fragment

    Science.gov (United States)

    Obonai, Toshifumi; Fuchigami, Hirobumi; Furuya, Fumiaki; Kozuka, Naoyuki; Yasunaga, Masahiro; Matsumura, Yasuhiro

    2016-01-01

    The diagnosis of early and aggressive types of cancer is important for providing effective cancer therapy. Cancer-induced fibrin clots exist only within lesions. Previously, we developed a monoclonal antibody (clone 102-10) that recognizes insoluble fibrin but not fibrinogen or soluble fibrin and confirmed that fibrin clots form continuously in various cancers. Here, we describe the development of a Fab fragment probe of clone 102-10 for tumour imaging. The distribution of 102-10 Fab was investigated in genetically engineered mice bearing pancreatic ductal adenocarcinoma (PDAC), and its effect on blood coagulation was examined. Immunohistochemical and ex vivo imaging revealed that 102-10 Fab was distributed selectively in fibrin clots in PDAC tumours 3 h after injection and that it disappeared from the body after 24 h. 102-10 Fab had no influence on blood coagulation or fibrinolysis. Tumour imaging using anti-fibrin Fab may provide a safe and effective method for the diagnosis of invasive cancers by detecting fibrin clots in tumour stroma. PMID:27009516

  9. Mechanical Stability and Fibrinolytic Resistance of Clots Containing Fibrin, DNA, and Histones*

    Science.gov (United States)

    Longstaff, Colin; Varjú, Imre; Sótonyi, Péter; Szabó, László; Krumrey, Michael; Hoell, Armin; Bóta, Attila; Varga, Zoltán; Komorowicz, Erzsébet; Kolev, Krasimir

    2013-01-01

    Neutrophil extracellular traps are networks of DNA and associated proteins produced by nucleosome release from activated neutrophils in response to infection stimuli and have recently been identified as key mediators between innate immunity, inflammation, and hemostasis. The interaction of DNA and histones with a number of hemostatic factors has been shown to promote clotting and is associated with increased thrombosis, but little is known about the effects of DNA and histones on the regulation of fibrin stability and fibrinolysis. Here we demonstrate that the addition of histone-DNA complexes to fibrin results in thicker fibers (increase in median diameter from 84 to 123 nm according to scanning electron microscopy data) accompanied by improved stability and rigidity (the critical shear stress causing loss of fibrin viscosity increases from 150 to 376 Pa whereas the storage modulus of the gel increases from 62 to 82 pascals according to oscillation rheometric data). The effects of DNA and histones alone are subtle and suggest that histones affect clot structure whereas DNA changes the way clots are lysed. The combination of histones + DNA significantly prolongs clot lysis. Isothermal titration and confocal microscopy studies suggest that histones and DNA bind large fibrin degradation products with 191 and 136 nm dissociation constants, respectively, interactions that inhibit clot lysis. Heparin, which is known to interfere with the formation of neutrophil extracellular traps, appears to prolong lysis time at a concentration favoring ternary histone-DNA-heparin complex formation, and DNase effectively promotes clot lysis in combination with tissue plasminogen activator. PMID:23293023

  10. Submillisecond elastic recoil reveals molecular origins of fibrin fiber mechanics.

    Science.gov (United States)

    Hudson, Nathan E; Ding, Feng; Bucay, Igal; O'Brien, E Timothy; Gorkun, Oleg V; Superfine, Richard; Lord, Susan T; Dokholyan, Nikolay V; Falvo, Michael R

    2013-06-18

    Fibrin fibers form the structural scaffold of blood clots. Thus, their mechanical properties are of central importance to understanding hemostasis and thrombotic disease. Recent studies have revealed that fibrin fibers are elastomeric despite their high degree of molecular ordering. These results have inspired a variety of molecular models for fibrin's elasticity, ranging from reversible protein unfolding to rubber-like elasticity. An important property that has not been explored is the timescale of elastic recoil, a parameter that is critical for fibrin's mechanical function and places a temporal constraint on molecular models of fiber elasticity. Using high-frame-rate imaging and atomic force microscopy-based nanomanipulation, we measured the recoil dynamics of individual fibrin fibers and found that the recoil was orders of magnitude faster than anticipated from models involving protein refolding. We also performed steered discrete molecular-dynamics simulations to investigate the molecular origins of the observed recoil. Our results point to the unstructured αC regions of the otherwise structured fibrin molecule as being responsible for the elastic recoil of the fibers. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  11. Fibrin-Targeted Magnetic Resonance Imaging Allows In Vivo Quantification of Thrombus Fibrin Content and Identifies Thrombi Amenable for Thrombolysis

    Science.gov (United States)

    Jenkins, Julia; Modarai, Bijan; Wiethoff, Andrea J.; Phinikaridou, Alkystis; Grover, Steven P.; Patel, Ashish S.; Schaeffter, Tobias; Smith, Alberto; Botnar, Rene M.

    2014-01-01

    Objective Deep venous thrombosis is a major health problem. Thrombolytic therapies are effective in recanalizing the veins and preventing post-thrombotic complications, but there is no consensus on selection criteria. The aim of this study was to investigate a fibrin-specific MRI contrast agent (EP-2104R) for the accurate quantification of thrombus’ fibrin content in vivo and for the identification of thrombus suitable for thrombolysis. Approach and Results Venous thrombosis was induced in the inferior vena cava of 8- to 10-week-old male BALB/C mice and MRI performed 2, 4, 7, 10, 14, and 21 days later. Eighteen mice were scanned at each time point pre and 2 hours post injection of EP-2104R (8.0 μmol/kg) with 12 mice at each time point used to correlate fibrin contrast uptake with thrombus’ histological stage and fibrin content. Six mice at each time point were immediately subjected to intravascular thrombolytic therapy (10 mg/kg of tissue-type plasminogen activator). Mice were imaged to assess response to lytic therapy 24 hours after thrombolytic treatment. Two mice at each time point were scanned post injection of 0.2 mmol/kg of Gd-DTPA (gadolinium with diethylenetriaminepentacetate, Magnevist, Schering AG, Berlin, Germany) for control purpose. Contrast uptake was correlated positively with the fibrin content of the thrombus measured by Western blotting (R2=0.889; PThrombus relaxation rate (R1) post contrast and the change in visualized thrombus size on late gadolinium enhancement inversion recovery MRI pre–EP-2104R and post–EP-2104R injection were the best predictors for successful thrombolysis (area under the curve, 0.989 [95% confidence interval, 0.97–1.00] and 0.994 [95% confidence interval, 0.98–1.00] respectively). Conclusions MRI with a fibrin-specific contrast agent accurately estimates thrombus fibrin content in vivo and identifies thrombi that are amenable for thrombolysis. PMID:24723557

  12. Fibrin related antigens: assay development, clinical and kinetic studies

    Energy Technology Data Exchange (ETDEWEB)

    Kruskal, J B

    1987-08-01

    This thesis describes an assay which is able to measure and to determine the proportions of fibrin- and fibrinogen-related antigens (FRA) present in clinical samples. No assay exists at present which is capable of distinguishing between fibrin and fibrinogen degradation products concurrently and in a clinical setting. The assay may be used as a tool with which to gain further insight to pathophysiology of disorders characterized by activation of the coagulation and fibrinolytic pathways. This study provides and analysis of the FRA profiles in patients with disorders characterised by possible enhanced fibrinolytic activity. Studies have been undertaken on patients with acute and chronic liver diseases, on patients with the various syndromes of coronary artery disease and on patients with insulin-dependent diabetes mellitus with and without evidence of microvascular disease. Certain observations made it evident that further studies were required in order to explain previously undocumented fibrinolytic abnormalities in certain patient groups. Data obtained from patients with liver disease provided information compatible with the activation of their fibrinolytic pathways. The initial scope of this study was then extended to further investigate the deranged haemostatic mechanisms in patients with severe liver diseases. Kinetic studies were performed which required the development of specific technology to be able to measure certain previously undertermined parameters. Mathematical models describing the rates of fibrin formation and lysis were developed for human studies. Fibrin-derived D-dimer was radiolabelled and its validity as and intravenous tracer and maker of fibrin degradation established.

  13. Platelet factor XIII increases the fibrinolytic resistance of platelet-rich clots by accelerating the crosslinking of alpha 2-antiplasmin to fibrin

    Science.gov (United States)

    Reed, G. L.; Matsueda, G. R.; Haber, E.

    1992-01-01

    Platelet clots resist fibrinolysis by plasminogen activators. We hypothesized that platelet factor XIII may enhance the fibrinolytic resistance of platelet-rich clots by catalyzing the crosslinking of alpha 2-antiplasmin (alpha 2AP) to fibrin. Analysis of plasma clot structure by polyacrylamide gel electrophoresis and immunoblotting revealed accelerated alpha 2AP-fibrin crosslinking in platelet-rich compared with platelet-depleted plasma clots. A similar study of clots formed with purified fibrinogen (depleted of factor XIII activity), isolated platelets, and specific factor XIII inhibitors indicated that this accelerated crosslinking was due to the catalytic activity of platelet factor XIII. Moreover, when washed platelets were aggregated by thrombin, there was evidence of platelet factor XIII-mediated crosslinking between platelet alpha 2AP and platelet fibrin(ogen). Specific inhibition (by a monoclonal antibody) of the alpha 2AP associated with washed platelet aggregates accelerated the fibrinolysis of the platelet aggregate. Thus in platelet-rich plasma clots, and in thrombin-induced platelet aggregates, platelet factor XIII actively formed alpha 2AP-fibrin crosslinks, which appeared to enhance the resistance of platelet-rich clots to fibrinolysis.

  14. Fibrin network pattern changes of platelet-rich fibrin in young versus old age group of individuals: A cell block cytology study

    Directory of Open Access Journals (Sweden)

    Shravanthi Raghav Yajamanya

    2016-01-01

    Full Text Available Background: To evaluate variations in fibrin network patterns of the platelet-rich fibrin (PRF in different age groups. Materials and Methods: Ninety-five patients were divided into three age groups: Group 1: (20–39 years; Group 2: (40–59 years; and Group 3: (60 years and above. PRF was prepared from blood samples of all patients and were subjected to cell block cytology method of histological analysis and slides were prepared to histologically assess the age-related changes in (i fibrin network patterns in terms of density and (ii entrapment of platelets and white blood cells (WBCs within fibrin meshwork. Results: Two types of fibrin network pattern arrangements noticed: Dense and loose types in three age groups. However, there was a noticeable decrease in the dense type of fibrin network with progressing age and increase in the loose type of fibrin arrangement. Furthermore, variation in a number of platelets and WBCs entrapped within fibrin network in relation to age was noticed. Conclusion: From the current study it can be concluded that age can be considered as one of the influencing factors on quality of PRF in terms of fibrin network patterns and hence, platelet and WBCs entrapment within these fibrin networks.

  15. Role of Fibrin Sealants in Liver Surgery

    NARCIS (Netherlands)

    de Boer, Marieke T.; Boonstra, Elizabeth A.; Lisman, Ton; Porte, Robert J.

    2012-01-01

    Background: Fibrin sealants are widely used in liver surgery. The aim of this article is to review the literature on evidence of hemostatic and biliostatic capacities of different fibrin sealants in liver surgery. Methods: In PubMed, a literature search was done with the search terms 'fibrin

  16. A recently developed bifacial platelet-rich fibrin matrix

    Directory of Open Access Journals (Sweden)

    E Lucarelli

    2010-07-01

    Full Text Available Platelet-rich plasma (PRP is used clinically in liquid or gel form to promote tissue repair. Because of the poor mechanical properties, conventional PRP is often difficult to handle when used in clinical settings and requires secure implantation in a specific site, otherwise when released growth factors could be washed out during an operation. In this study, we analyzed the end product of a recently developed commercially available system (FIBRINET®, which is a dense pliable, platelet-rich fibrin matrix (PRFM. We characterized the mechanical properties of PRFM and tested whether PRFM releases growth factors and whether released factors induce the proliferation of mesenchymal stem cells (MSC. Mechanical properties as well as platelet distribution were evaluated in PRFM. PRFM demonstrated robust mechanical properties, with a tear elastic modulus of 937.3 + 314.6 kPa, stress at a break of 1476.0 + 526.3 kPa, and an elongation at break of 146.3 + 33.8 %. PRFM maintained its mechanical properties throughout the testing process. Microscopic observations showed that the platelets were localized on one side of the matrix. Elevated levels of PDGF-AA, PDGF-AB, EGF, VEGF, bFGF and TGF-β1 were measured in the day 1-conditioned media (CM of PRFM and growth factor levels decreased thereafter. BMP2 and BMP7 were not detectable. MSC culture media supplemented with 20% PRFM-CM stimulated MSC cell proliferation; at 24 and 48 hours the induction of the proliferation was significantly greater than the induction obtained with media supplemented with 20% foetal bovine serum. The present study shows that the production of a dense, physically robust PRFM made through high-speed centrifugation of intact platelets and fibrin in the absence of exogenous thrombin yields a potential tool for accelerating tissue repair.

  17. A review of bioceramics and fibrin sealant.

    Science.gov (United States)

    Le Guéhennec, L; Layrolle, P; Daculsi, G

    2004-09-13

    This review focuses on bone substitute composites made by mixing ceramic biomaterials with fibrin sealants. Different biomaterials such as coral, bone-derived materials, bioactive glass ceramics, and synthetic calcium phosphate have been mixed with fibrin sealant, resulting in a combination of the biological properties of the two components. This type of association has not produced identical results in all studies. In the past for some, the addition of fibrin sealant to the biomaterial failed to produce any significant, positive effect on osteointegration, whereas others found a positive impact on bone colonization. Despite the negative biological effects reported previously, bioceramic-fibrin composites have been widely used in various types of bone surgery because they are easy to manipulate. In particular, the intra-operative preparation of these composites makes it possible to add bone growth factors or autologous osteoprogenitor cells prior to bone reconstruction. The bone growth factors and autologous osteoprogenitor cells associated with the bioceramic-fibrin composites should provide surgeons with tissue engineered grafts with enhanced osteointegrative properties. This review discusses both the advantages and disadvantages, as well as the future perspectives, of using bioceramic-fibrin composites in various clinical indications.

  18. A Review of Bioceramics and Fibrin Sealant

    Directory of Open Access Journals (Sweden)

    Le Guéhennec L.

    2004-09-01

    Full Text Available This review focuses on bone substitute composites made by mixing ceramic biomaterials with fibrin sealants. Different biomaterials such as coral, bone-derived materials, bioactive glass ceramics, and synthetic calcium phosphate have been mixed with fibrin sealant, resulting in a combination of the biological properties of the two components. This type of association has not produced identical results in all studies. In the past for some, the addition of fibrin sealant to the biomaterial failed to produce any significant, positive effect on osteointegration, whereas others found a positive impact on bone colonization. Despite the negative biological effects reported previously, bioceramic-fibrin composites have been widely used in various types of bone surgery because they are easy to manipulate. In particular, the intra-operative preparation of these composites makes it possible to add bone growth factors or autologous osteoprogenitor cells prior to bone reconstruction. The bone growth factors and autologous osteoprogenitor cells associated with the bioceramic-fibrin composites should provide surgeons with tissue engineered grafts with enhanced osteointegrative properties. This review discusses both the advantages and disadvantages, as well as the future perspectives, of using bioceramic-fibrin composites in various clinical indications.

  19. Fibrin glue mixed with platelet-rich fibrin as a scaffold seeded with dental bud cells for tooth regeneration.

    Science.gov (United States)

    Yang, Kai-Chiang; Wang, Chun-Hao; Chang, Hao-Hueng; Chan, Wing P; Chi, Chau-Hwa; Kuo, Tzong-Fu

    2012-11-01

    Odontogenesis is a complex process with a series of epithelial-mesenchymal interactions and odontogenic molecular cascades. In tissue engineering of teeth from stem cells, platelet-rich fibrin (PRF), which is rich in growth factors and cytokines, may improve regeneration. Accordingly, PRF was added into fibrin glue to enrich the microenvironment with growth factors. Unerupted second molar tooth buds were harvested from miniature swine and cultured in vitro for 3 weeks to obtain dental bud cells (DBCs). Whole blood was collected for the preparation of PRF and fibrin glue before surgery. DBCs were suspended in fibrin glue and then enclosed with PRF, and the DBC-fibrin glue-PRF composite was autografted back into the original alveolar sockets. Radiographic and histological examinations were used to identify the regenerated tooth structure 36 weeks after implantation. Immunohistochemical staining was used to detect proteins specific to tooth regeneration. One pig developed a complete tooth with crown, root, pulp, enamel, dentin, odontoblast, cementum, blood vessels, and periodontal ligaments in indiscriminate shape. Another animal had an unerupted tooth that expressed cytokeratin 14, dentin matrix protein-1, vascular endothelial growth factor, and osteopontin. This study demonstrated, using autogenic cell transplantation in a porcine model, that DBCs seeded into fibrin glue-PRF could regenerate a complete tooth. Copyright © 2011 John Wiley & Sons, Ltd.

  20. Submillisecond Elastic Recoil Reveals Molecular Origins of Fibrin Fiber Mechanics

    Science.gov (United States)

    Hudson, Nathan E.; Ding, Feng; Bucay, Igal; O’Brien, E. Timothy; Gorkun, Oleg V.; Superfine, Richard; Lord, Susan T.; Dokholyan, Nikolay V.; Falvo, Michael R.

    2013-01-01

    Fibrin fibers form the structural scaffold of blood clots. Thus, their mechanical properties are of central importance to understanding hemostasis and thrombotic disease. Recent studies have revealed that fibrin fibers are elastomeric despite their high degree of molecular ordering. These results have inspired a variety of molecular models for fibrin’s elasticity, ranging from reversible protein unfolding to rubber-like elasticity. An important property that has not been explored is the timescale of elastic recoil, a parameter that is critical for fibrin’s mechanical function and places a temporal constraint on molecular models of fiber elasticity. Using high-frame-rate imaging and atomic force microscopy-based nanomanipulation, we measured the recoil dynamics of individual fibrin fibers and found that the recoil was orders of magnitude faster than anticipated from models involving protein refolding. We also performed steered discrete molecular-dynamics simulations to investigate the molecular origins of the observed recoil. Our results point to the unstructured αC regions of the otherwise structured fibrin molecule as being responsible for the elastic recoil of the fibers. PMID:23790375

  1. Biomimetic chimeric peptide-tethered hydrogels for human mesenchymal stem cell delivery.

    Science.gov (United States)

    Shim, Gayong; Kim, Gunwoo; Choi, Junhyeok; Yi, TacGhee; Cho, Yun Kyoung; Song, Sun Uk; Byun, Youngro; Oh, Yu-Kyoung

    2015-12-01

    Here, we report a chimeric peptide-tethered fibrin hydrogel scaffold for delivery of human mesenchymal stem cells (hMSC). Osteopontin-derived peptide (OP) was used as an hMSC-tethering moiety. OP showed hMSC adhesion properties and enhanced hMSC proliferation. A natural fibrin-binding protein-derived peptide (FBP) was tested for its ability to tether hMSC to the fibrin gel matrix. FBP loading on fibrin gels was 8.2-fold higher than that of a scrambled peptide (scFBP). FBP-loaded fibrin gels were retained at injection sites longer than scFBP-loaded fibrin gels, showing a 15.9-fold higher photon intensity of fluorescent FBP-grafted fibrin gels than fluorescent scFBP-loaded fibrin gels 48 h after injection. On the basis of the fibrin gel-binding properties of FBP and the hMSC-binding and proliferation-supporting properties of OP, we constructed chimeric peptides containing FBP and OP linked with a spacer (FBPsOP). Four days after transplantation, the survival of hMSC in FBPsOP-grafted fibrin gels was 3.9-fold higher than hMSC in fibrin gels alone. Our results suggest the potential of FBPsOP-grafted fibrin gels as a bioactive delivery system for enhanced survival of stem cells. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. SPECT imaging of fibrin using fibrin-binding peptides

    NARCIS (Netherlands)

    Starmans, L.W.E.; Duijnhoven, van S.M.J.; Rossin, R.; Aime, S.; Daemen, M.J.A.P.; Nicolay, K.; Grüll, H.

    2013-01-01

    Noninvasive detection of fibrin in vivo using diagnostic imaging modalities may improve clinical decision-making on possible therapeutic options in atherosclerosis, cancer and thrombus-related pathologies such as pulmonary embolism and deep venous thrombosis. The aim of this study was to assess the

  3. Comparison of standard fibrinogen measurement methods with fibrin clot firmness assessed by thromboelastometry in patients with cirrhosis.

    Science.gov (United States)

    Vucelic, Dragica; Jesic, Rada; Jovicic, Snezana; Zivotic, Maja; Grubor, Nikica; Trajkovic, Goran; Canic, Ivana; Elezovic, Ivo; Antovic, Aleksandra

    2015-06-01

    The Clauss fibrinogen method and thrombin clotting time (TCT) are still routinely used in patients with cirrhosis to define fibrinogen concentration and clotting potential. The thromboelastometric functional fibrinogen FIBTEM assay evaluates the strength of fibrin-based clots in whole blood, providing information on both quantitative deficit and fibrin polymerization disorders. To compare these three methods of assessing fibrinogen in patients with cirrhosis of different aetiologies, characterized by impairment in fibrinogen concentration as well as functional aberrance. Sixty patients with alcoholic and 24 patients with cholestatic cirrhosis were included (Child-Pugh score (CPs)A, n=24; B, n=32; C, n=28). All parameters were compared with those from a control group. Maximum clot firmness (MCF) in the FIBTEM test was assessed in regard to its relevance in detection of qualitative fibrinogen disorders in comparison with results obtained by standard measurement methods, i.e. the Clauss fibrinogen method and TCT. With increased cirrhosis severity, fibrinogen and FIBTEM-MCF levels significantly declined (p=0.002), while TCT was significantly prolonged (p=0.002). In all CPs groups, fibrinogen strongly correlated with FIBTEM-MCF (r=0.77, r=0.72, r=0.74; pmeasurement in cirrhotic patients, especially in evaluating fibrin polymerization disorders in these patients. Further studies are needed to evaluate the usefulness of this assay in predicting bleeding complications in cirrhotic patients as well as monitoring replacement treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Platelet-rich fibrin: the benefits.

    Science.gov (United States)

    Kumar, Yuvika Raj; Mohanty, Sujata; Verma, Mahesh; Kaur, Raunaq Reet; Bhatia, Priyanka; Kumar, Varun Raj; Chaudhary, Zainab

    2016-01-01

    Current published data presents confusing results about the effects of platelet-rich fibrin on bone, and there is a need for studies that throw light on its effect. Our main objective therefore was to evaluate (by fractal analysis) osseous regeneration in extraction sockets with and without platelet-rich fibrin in a study with a substantial sample and a reliable technique to calibrate its effects on bone cells. We also assessed the soft tissue response. Thirty-four patients had their bilaterally impacted third molars (68 surgical sites) extracted in this split-mouth study, following which platelet-rich fibrin was placed in one of the sockets. Patients were followed up clinically and radiographically, and a pain score and fractal analysis were used to evaluate healing of soft tissue and bone, respectively. We conclude that platelet-rich fibrin improves healing of both soft and hard tissues. Although osseous healing did not differ significantly between the groups, healing of soft tissue as judged by the pain score was significantly better in the experimental group. Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. Comparison of mechanical compressive properties of commercial and autologous fibrin glues for tissue engineering applications.

    Science.gov (United States)

    Cravens, Matthew G; Behn, Anthony W; Dragoo, Jason L

    2017-11-01

    Fibrin glues are widely used in orthopedic surgery as adhesives and hemostatic agents. We evaluated the compressive properties of selected fibrin glues in order to identify which are appropriate for tissue regeneration applications subject to compression. Uniaxial unconfined compression tests were performed on fibrin gels prepared from commercial and autologous products: (1) Evicel (Ethicon), (2) Tisseel (Baxter), (3) Angel (Arthrex), and (4) ProPlaz (Biorich). Cyclic loads were applied from 0 to 30% strain for 100cycles at 0.5Hz. Following cyclic testing, specimens were subjected to ramp displacement of 1% strain per second to 80% strain. Throughout cyclic loading, Evicel and Tisseel deformed (shortened) less than Angel at all but one time point, and deformed less than ProPlaz at cycles 10 and 20. The dynamic moduli, peak stress, and strain energy were significantly greater in Tisseel than all other groups. Evicel displayed significantly greater dynamic moduli, peak stress, and strain energy than Angel and ProPlaz. Following cyclic testing, Tisseel and Evicel were significantly less deformed than Angel. No specimens exhibited gross failure during ramp loading to 80% strain. Ramp loading trends mirrored those of cyclic loading. The tested commercial glues were significantly more resistant to compression than the autologous products. The compressive properties of Tisseel were approximately twice those of Evicel. All preparations displayed moduli multiple orders of magnitude less than that of native articular cartilage. We conclude that in knee surgeries requiring fibrin glue to undergo compression of daily activity, commercial products are preferable to autologous preparations from platelet-poor plasma, though both will deform significantly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Stretching single fibrin fibers hampers their lysis.

    Science.gov (United States)

    Li, Wei; Lucioni, Tomas; Li, Rongzhong; Bonin, Keith; Cho, Samuel S; Guthold, Martin

    2017-09-15

    Blood clots, whose main structural component is a mesh of microscopic fibrin fibers, experience mechanical strain from blood flow, clot retraction and interactions with platelets and other cells. We developed a transparent, striated and highly stretchable substrate made from fugitive glue (a styrenic block copolymer) to investigate how mechanical strain affects lysis of single, suspended fibrin fibers. In this suspended fiber assay, lysis manifested itself by fiber elongation, thickening (disassembly), fraying and collapse. Stretching single fibrin fibers significantly hampered their lysis. This effect was seen in uncrosslinked and crosslinked fibers. Crosslinking (without stretching) also hampered single fiber lysis. Our data suggest that strain is a novel mechanosensitive factor that regulates blood clot dissolution (fibrinolysis) at the single fiber level. At the molecular level of single fibrin molecules, strain may distort, or hinder access to, plasmin cleavage sites and thereby hamper lysis. Fibrin fibers are the major structural component of a blood clot. We developed a highly stretchable substrate made from fugitive glue and a suspended fibrin fiber lysis assay to investigate the effect of stretching on single fibrin fibers lysis. The key findings from our experiments are: 1) Fibers thicken and elongate upon lysis; 2) stretching strongly reduces lysis; 3) this effect is more pronounced for uncrosslinked fibers; and 4) stretching fibers has a similar effect on reducing lysis as crosslinking fibers. At the molecular level, strain may distort plasmin cleavage sites, or restrict access to those sites. Our results suggest that strain may be a novel mechanobiological factor that regulates fibrinolysis. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  7. 21 CFR 864.7320 - Fibrinogen/fibrin degradation products assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fibrinogen/fibrin degradation products assay. 864.7320 Section 864.7320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN....7320 Fibrinogen/fibrin degradation products assay. (a) Identification. A fibrinogen/fibrin degradation...

  8. Use of fibrin sealants in cardiovascular surgery: a systematic review.

    Science.gov (United States)

    Rousou, John A

    2013-05-01

    Fibrin sealants are used for hemostasis and tissue adherence. This systematic review summarizes published clinical data for fibrin sealant use in cardiovascular surgery. A literature search for the following terms was conducted using PubMed and EMBASE: (TISSEEL or Tissucol or Beriplast P or Evicel or Quixil or Crosseal or Reliseal or Fibringluraas or Bolheal or Tachosil or Vivostat or Vitagel or Artiss or "fibrin glue" or "fibrin sealant" or "fibrin tissue adhesive") and (cardiac or cardiovascular or vascular or heart or coronary or surgery). Case reports and series were excluded; although reports of controlled trials were preferred, uncontrolled trial data were also considered. Clinical trials and chart review analyses of fibrin sealants were identified and summarized. Although clinical trial data were available for other agents, the majority of published studies examined TISSEEL. Overall, TISSEEL and other fibrin sealants showed improvements over standard of care or control groups for a variety of predefined endpoints. Safety findings are also summarized. Data from these studies showed that fibrin sealants were well tolerated and provided effective hemostasis in a range of cardiac and aortic surgeries. © 2013 Wiley Periodicals, Inc.

  9. Biomaterials for Improved Wound Healing

    Science.gov (United States)

    2013-10-01

    is silver sulphadiazine (SSD) [6-7]. SSD possesses a broad spectrum of activity against gram- positive and gram-negative bacteria as well as fungi [8... polyethylene glycol-based fibrin gel (PEGylated fibrin gel) induces vasculogenesis both in vitro and in vivo [20]. To exploit the inherent ability of fibrin as...Loaded Chitosan Microspheres Impregnated in Polyethylene Glycol Fibrin Gels (SSD-CSM-PEGylated fibrin gels) and Adipose Derived Stem Cells embedded

  10. Fibrin-Enhanced Canonical Wnt Signaling Directs Plasminogen Expression in Cementoblasts

    Directory of Open Access Journals (Sweden)

    Saeed Ur Rahman

    2017-11-01

    Full Text Available Cementum is a mineralized layer on the tooth’s root surface and facilitates the biomechanical anchoring of fibrous connective tissues as a part of tooth-supportive complexes. Previously, we observed that OCCM30 cementoblasts cultured on fibrin matrices underwent apoptosis due to fibrin degradation through the expression of proteases. Here, we demonstrated that OCCM30 on fibrin matrices (OCCM30-fibrin enhanced canonical Wnt signaling, which directed to plasminogen expression. The OCCM30-fibrin showed higher levels of Wnt3a expression, nuclear translocation of β-catenin, and T-cell factor (TCF optimal motif (TOP reporter activity than the cells on tissue culture dishes (OCCM30-TCD, indicating that the OCCM30-fibrin enhanced canonical Wnt/β-catenin signaling. Also, OCCM30-fibrin expressed biomineralization-associated markers at higher levels than OCCM30-TCD, of which levels were further increased with LiCl, a Wnt signaling activator. The OCCM30 cementoblasts simultaneously showed that high levels of plasminogen, a critical component of fibrinolysis, were expressed in the OCCM30-fibrin. Activation of canonical Wnt signaling with LiCl treatment or with forced lymphoid enhancer factor 1 (LEF1-expression increased the expression of plasminogen. On the contrary, the inhibition of canonical Wnt signaling with siRNAs against Wnt3a or β-catenin abrogated fibrin-enhanced plasminogen expression. Furthermore, there are three conserved putative response elements for the LEF1/β-catenin complex in the plasminogen proximal promoter regions (−900 to +54. Site-directed mutations and chromatin immunoprecipitation indicated that canonical Wnt signaling directed plasminogen expression. Taken together, this study suggests that fibrin-based materials can modulate functional periodontal formations in controlling cementoblast differentiation and fibrin degradation.

  11. Injectable alginate-O-carboxymethyl chitosan/nano fibrin composite hydrogels for adipose tissue engineering.

    Science.gov (United States)

    Jaikumar, Dhanya; Sajesh, K M; Soumya, S; Nimal, T R; Chennazhi, K P; Nair, Shantikumar V; Jayakumar, R

    2015-03-01

    Injectable, biodegradable scaffolds are required for soft tissue reconstruction owing to its minimally invasive approach. Such a scaffold can mimic the native extracellular matrix (ECM), provide uniform distribution of cells and overcome limitations like donor site morbidity, volume loss, etc. So, here we report two classes of biocompatible and biodegradable hydrogel blend systems namely, Alginate/O-carboxymethyl chitosan (O-CMC) and Alginate/poly (vinyl alcohol) (PVA) with the inclusion of fibrin nanoparticles in each. The hydrogels were prepared by ionic cross-linking method. The developed hydrogels were compared in terms of its swelling ratio, degradation profile, compressive strength and elastic moduli. From these preliminary findings, it was concluded that Alginate/O-CMC formed a better blend for tissue engineering applications. The potential of the formed hydrogel as an injectable scaffold was revealed by the survival of adipose derived stem cells (ADSCs) on the scaffold by its adhesion, proliferation and differentiation into adipocytes. Cell differentiation studies of fibrin incorporated hydrogel scaffolds showed better differentiation was confirmed by Oil Red O staining technique. These injectable gels have potential in soft tissue regeneration. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Circulating Microparticles Alter Formation, Structure, and Properties of Fibrin Clots.

    Science.gov (United States)

    Zubairova, Laily D; Nabiullina, Roza M; Nagaswami, Chandrasekaran; Zuev, Yuriy F; Mustafin, Ilshat G; Litvinov, Rustem I; Weisel, John W

    2015-12-04

    Despite the importance of circulating microparticles in haemostasis and thrombosis, there is limited evidence for potential causative effects of naturally produced cell-derived microparticles on fibrin clot formation and its properties. We studied the significance of blood microparticles for fibrin formation, structure, and susceptibility to fibrinolysis by removing them from platelet-free plasma using filtration. Clots made in platelet-free and microparticle-depleted plasma samples from the same healthy donors were analyzed in parallel. Microparticles accelerate fibrin polymerisation and support formation of more compact clots that resist internal and external fibrinolysis. These variations correlate with faster thrombin generation, suggesting thrombin-mediated kinetic effects of microparticles on fibrin formation, structure, and properties. In addition, clots formed in the presence of microparticles, unlike clots from the microparticle-depleted plasma, contain 0.1-0.5-μm size granular and CD61-positive material on fibres, suggesting that platelet-derived microparticles attach to fibrin. Therefore, the blood of healthy individuals contains functional microparticles at the levels that have a procoagulant potential. They affect the structure and stability of fibrin clots indirectly through acceleration of thrombin generation and through direct physical incorporation into the fibrin network. Both mechanisms underlie a potential role of microparticles in haemostasis and thrombosis as modulators of fibrin formation, structure, and resistance to fibrinolysis.

  13. Fibrin Sealants in Dura Sealing: A Systematic Literature Review.

    Directory of Open Access Journals (Sweden)

    Felice Esposito

    Full Text Available Fibrin sealants are widely used in neurosurgery to seal the suture line, provide watertight closure, and prevent cerebrospinal fluid leaks. The aim of this systematic review is to summarize the current efficacy and safety literature of fibrin sealants in dura sealing and the prevention/treatment of cerebrospinal fluid leaks.A comprehensive electronic literature search was run in the following databases: Cochrane Database of Systematic Reviews, Cochrane Central Resister of Controlled Trials, clinicaltrials.gov, MEDLINE/PubMed, and EMBASE. Titles and abstracts of potential articles of interest were reviewed independently by 3 of the authors.A total of 1006 database records and additional records were identified. After screening for duplicates and relevance, a total of 78 articles were assessed by the investigators for eligibility. Thirty-eight were excluded and the full-text of 40 articles were included in the qualitative synthesis. Seven of these included only safety data and were included in the safety assessment. The remaining 33 articles included findings from 32 studies that enrolled a total of 2935 patients who were exposed to fibrin sealant. Among these 33 studies there were only 3 randomized controlled trials, with the remaining being prospective cohort analysis, case controlled studies, prospective or retrospective case series. One randomized controlled trial, with 89 patients exposed to fibrin sealant, found a greater rate of intraoperative watertight dura closure in the fibrin sealant group than the control group (92.1% versus 38.0%, p0.05. Other clinical trials evaluated the effect of fibrin sealant in the postoperative prevention of cerebrospinal fluid leaks. These were generally lower level evidence studies (ie, not prospective, randomized, controlled trials that were not designed or powered to demonstrate a significant advantage to fibrin sealant use. Two small case series studies evaluated the effect of fibrin sealants in

  14. Role of plasma-rich fibrin in oral surgery

    OpenAIRE

    Kumar, K. Retna; Genmorgan, K.; Abdul Rahman, S. M.; Rajan, M. Alaguvel; Kumar, T. Arul; Prasad, V. Srinivas

    2016-01-01

    Platelet-rich fibrin (PRF) is a fibrin meshwork, in which platelet cytokines, growth factors, and cells are entrapped and discharged after a period and can serve as a resorbable film. PRF is the next generation of platelet concentrates equipped to improve arrangement without biochemical blood handling; PRF is an evolution of the fibrin adhesive, which is widely used in the oral surgery. The guidelines of this innovation depend on concentrating platelets and growth factors in a plasma medium, ...

  15. A CCR2 macrophage endocytic pathway mediates extravascular fibrin clearance in vivo

    DEFF Research Database (Denmark)

    Motley, Michael P; Madsen, Daniel H; Jürgensen, Henrik J

    2016-01-01

    cellular endocytosis and lysosomal targeting, revealing a novel intracellular pathway for extravascular fibrin degradation. A C-C chemokine receptor type 2 (CCR2)-positive macrophage subpopulation constituted the majority of fibrin-uptaking cells. Consequently, cellular fibrin uptake was diminished...... by elimination of CCR2-expressing cells. The CCR2-positive macrophage subtype was different from collagen-internalizing M2-like macrophages. Cellular fibrin uptake was strictly dependent on plasminogen and plasminogen activator. Surprisingly, however, fibrin endocytosis was unimpeded by the absence of the fibrin...... subsets of macrophages employing distinct molecular pathways....

  16. Bone induction by composites of bioresorbable carriers and demineralized bone in rats: a comparative study of fibrin-collagen paste, fibrin sealant, and polyorthoester with gentamicin

    DEFF Research Database (Denmark)

    Pinholt, E M; Solheim, E; Bang, G

    1992-01-01

    fibrin-collagen paste and fibrin sealant inhibited bone induction and produced a chronic inflammation; part of the fibrin-collagen paste was still present at 4 weeks. Polyorthoester with gentamicin was almost completely absorbed, induced minimal tissue reaction, and did not inhibit osteoinduction....

  17. Do fibrin sealants impact negative outcomes after robot-assisted partial nephrectomy?

    Science.gov (United States)

    Cohen, Jason; Jayram, Gautam; Mullins, Jeffrey K; Ball, Mark W; Allaf, Mohamad E

    2013-10-01

    Contemporary rates of postoperative hemorrhage after partial nephrectomy (PN) are low. Commercially available hemostatic agents are commonly used during this surgery to reduce this risk despite a paucity of data supporting the practice. We assessed the impact of fibrin sealant hemostatic agents, a costly addition to surgeries, during robot-assisted partial nephrectomy (RAPN). Between 2007 and 2011, 114 consecutive patients underwent RAPN by a single surgeon (MEA). Evicel fibrin sealant was used in the first 74 patients during renorraphy. The last 40 patients had renorraphy performed without the use of any hemostatic agents. Clinicopathologic, operative, and complication data were compared between groups. Multivariate and univariate logistic regression analysis was performed to test the association between the use of fibrin sealants and operative outcomes. Patient demographic data and clinical tumor characteristics were similar between groups. The use of fibrin sealant did not increase operative time (166.3 vs 176.1 minutes, P=0.28), warm ischemia time (WIT) (14.4 vs 16.1 minutes, P=0.18), or length of hospital stay (2.6 vs 2.4 days, P=0.35). The omission of these agents did not increase estimated blood loss (116.6 vs 176.1 mL, P=0.8) or postoperative blood transfusion (0% vs 2.5%, P=0.17). Univariate analysis demonstrated no association between use of fibrin sealants and increased complications (P>0.05). Multivariable logistic regression showed no statistically significant predictive value of omission of hemostatic agents for perioperative outcomes (P>0.05). Perioperative hemorrhage and other major complications after contemporary RAPN are rare in experienced hands. In our study, the use of fibrin sealants during RAPN does not decrease the rate of complications, blood loss, or hospital stay. Furthermore, no impact is seen on operative time, WIT, or other negative outcomes. Omitting these agents during RAPN could be a safe, effective, cost-saving measure.

  18. Fibrin network pattern changes of platelet-rich fibrin in young versus old age group of individuals: A cell block cytology study

    OpenAIRE

    Shravanthi Raghav Yajamanya; Anirban Chatterjee; Chaitanya Nischay Babu; Deepika Karunanithi

    2016-01-01

    Background: To evaluate variations in fibrin network patterns of the platelet-rich fibrin (PRF) in different age groups. Materials and Methods: Ninety-five patients were divided into three age groups: Group 1: (20?39 years); Group 2: (40?59 years); and Group 3: (60 years and above). PRF was prepared from blood samples of all patients and were subjected to cell block cytology method of histological analysis and slides were prepared to histologically assess the age-related changes in (i) fibrin...

  19. The application of large amplitude oscillatory stress in a study of fully formed fibrin clots

    Science.gov (United States)

    Lamer, T. F.; Thomas, B. R.; Curtis, D. J.; Badiei, N.; Williams, P. R.; Hawkins, K.

    2017-12-01

    The suitability of controlled stress large amplitude oscillatory shear (LAOStress) for the characterisation of the nonlinear viscoelastic properties of fully formed fibrin clots is investigated. Capturing the rich nonlinear viscoelastic behaviour of the fibrin network is important for understanding the structural behaviour of clots formed in blood vessels which are exposed to a wide range of shear stresses. We report, for the first time, that artefacts due to ringing exist in both the sample stress and strain waveforms of a LAOStress measurement which will lead to errors in the calculation of nonlinear viscoelastic properties. The process of smoothing the waveforms eliminates these artefacts whilst retaining essential rheological information. Furthermore, we demonstrate the potential of LAOStress for characterising the nonlinear viscoelastic properties of fibrin clots in response to incremental increases of applied stress up to the point of fracture. Alternating LAOStress and small amplitude oscillatory shear measurements provide detailed information of reversible and irreversible structural changes of the fibrin clot as a consequence of elevated levels of stress. We relate these findings to previous studies involving large scale deformations of fibrin clots. The LAOStress technique may provide useful information to help understand why some blood clots formed in vessels are stable (such as in deep vein thrombosis) and others break off (leading to a life threatening pulmonary embolism).

  20. Diffusion measurement in ferrous infused gel dosimeters

    International Nuclear Information System (INIS)

    Zahmatkesh, M. H.; Healy, B. J.

    2003-01-01

    Background: The compositions of Ferrous sulphate, Agarose and Xylenol orange dye and Ferrous sulphate, Gelatin and Xylenol orange dye in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. Ionizing radiation causes oxidation of Fe 2+ ion to Fe 3+ ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours after irradiation. Materials and methods: 25 m M sulphuric acid, 0.4 mm ferrous ammonium sulphate, 0.2 mm xylenol orange dye and 1% by weight agarose in distilled water named Agarose and Xylenol orange dye and 0.1 mm ferrous ammonium sulphate, 0.1 mm xylenol orange dye, 50 mm sulphuric acid and 5% by weight gelatin in distilled water named Gelatin and Xylenol orange dye are used as two gel dosimeters. All chemicals were supplied by Sigma Ald ridge Company, Germany. The gels were poured in Perspex casts and were irradiated to a beam of X ray from linear accelerators or X ray machine. Results: In this study diffusion coefficients of Agarose and Xylenol orange dye and Gelatin and Xylenol orange dye dosimeters have been measured through a computer program for different temperature. The ferric ion diffusion coefficient (D) for the Agarose and Xylenol orange dye and Gelatin and Xylenol orange dye dosimeters were measured as (1.19.±0.03) x 10 -2 cm 2 .hr -1 and (0.83±0.03) x 10 -2 cm 2 .hr -1 respectively at room temperature. Conclusion: For both dosimeters the diffusion coefficients decreased with gel storage temperatures down to 6 d ig C . Gelatin and Xylenol orange dye dosimeters have advantage of lower diffusion coefficient for a specified temperature

  1. Predictive factors for anterior chamber fibrin formation after vitreoretinal surgery

    Directory of Open Access Journals (Sweden)

    Leonardo Provetti Cunha

    2014-04-01

    Full Text Available Purpose: The aim of this study was to investigate possible predictive factors related to anterior chamber fibrin formation after vitreoretinal surgery in a large series of patients. Methods: The data of 185 eyes of 185 patients submitted to vitreoretinal surgery was reviewed. The following variables were evaluated: the postoperatively presence of fibrin, age, diabetes mellitus, the vitrectomy system gauge (20, 23 or 25 gauge, the type of vitreous substitute, the influence of prior surgical procedures and the combination with cataract extraction. To evaluate predictive factors for anterior chamber fibrin formation, univariate analysis was performed. A multivariate stepwise logistic regression model was adjusted to investigate factors associated with fibrin formation (p<0.05. Results: Fibrinoid anterior chamber reaction was found in 12 (6.4% patients. For multivariate logistic regression analysis, balanced salt solution (BSS, the chance of fibrin occurrence was 5 times greater (odds ratio 4.83, CI 95% 1.302 - 17.892; p=0.019, while combination with phacoemulsification increased the chance of fibrin formation by 20 times (odds ratio 20, CI 95% 2.480 - 161.347; p=0.005. No significant difference was found regarding other variables. Conclusion: Anterior chamber fibrin formation is an unwanted complication after vitreoretinal surgery. Factors such as combined performance of phacoemulsification and the use of balanced salt solution as a vitreous substitute may predispose the occurrence of this complication.

  2. Efficacy of leukocyte- and platelet-rich fibrin in wound healing: a randomized controlled clinical trial.

    Science.gov (United States)

    Chignon-Sicard, Bérengère; Georgiou, Charalambos A; Fontas, Eric; David, Sylvain; Dumas, Pierre; Ihrai, Tarik; Lebreton, Elisabeth

    2012-12-01

    Application of platelet concentrates to wounds could speed healing. Leukocyte- and platelet-rich fibrin, a relatively recent development, stands out from the other preparations. This prospective, randomized, controlled clinical trial studied the rate of healing of postoperative hand wounds after a single application of leukocyte- and platelet-rich fibrin. Eligible patients were healthy individuals older than 18 years who had been scheduled for elective McCash (open palm) surgery for Dupuytren disease at the Plastic and Hand Surgery Department of Nice's University Hospital between August of 2007 and February of 2010. The control group received the reference care of petroleum jelly mesh (Vaselitulle), and test patients had leukocyte- and platelet-rich fibrin applied. The primary endpoint was healing delay measured in postoperative days. Secondary endpoints included pain, bleeding, and wound exudate. The trial was carried out as a single-blind trial. Among the 68 randomized patients, 33 patients in the leukocyte- and platelet-rich fibrin group and 31 in the Vaselitulle group were analyzed. Primary endpoint analysis showed a median healing delay of 24 days (interquartile range, 18 to 28 days) for the fibrin group and 29 days (interquartile range, 26 to 35 days) for the Vaselitulle group (p = 0.014, log-rank test). Postoperative pain assessment, bleeding, and exudate were always lower for the fibrin group, but not significantly so. The authors trial demonstrates that a single leukocyte- and platelet-rich fibrin application on fresh postoperative hand wounds shows a median improvement of 5 days in comparison with the standard treatment. Therapeutic, II.

  3. Contaminating fibrin in CPD-blood: solubility in plasma and distribution in blood components following separation

    International Nuclear Information System (INIS)

    Skjonsberg, O.H.; Kierulf, P.; Gravem, K.; Fagerhol, M.K.; Godal, H.C.

    1986-01-01

    In order to estimate the solubility of contaminating fibrin in CPD-blood, thrombin induced fibrin polymerzation in CPD-plasma was examined by light scattering and fibrinopeptide A (FPA) determinations. In addition, I-125 fibrin monomer enriched CPD-blood was used to investigate fibrin monomer retention in blood bags and transfusion filters (170 microns) and fibrin distribution in blood components derived from CPD-blood. Initial fibrin polymerization in CPD-blood occurred after conversion of 15 per cent of the fibrinogen to fibrin, implying that substantial amounts of fibrin may be kept solubilized in CPD-blood bags. Only minor amounts of I-125 fibrin monomers were retained in blood bags (2.4 per cent) and in transfusion filters (2.9 per cent) after sham transfusions. After separating I-125-fibrin monomer enriched CPD-blood into its constituent components, the major part of fibrin (75.0 per cent) could be traced in the cryoprecipitate

  4. A novel platelet concentrate: titanium-prepared platelet-rich fibrin.

    Science.gov (United States)

    Tunalı, Mustafa; Özdemir, Hakan; Küçükodacı, Zafer; Akman, Serhan; Yaprak, Emre; Toker, Hülya; Fıratlı, Erhan

    2014-01-01

    We developed a new product called titanium-prepared platelet-rich fibrin (T-PRF). The T-PRF method is based on the hypothesis that titanium may be more effective in activating platelets than the silica activators used with glass tubes in Chouckroun's leukocyte- and platelet-rich fibrin (L-PRF) method. In this study, we aimed to define the structural characteristics of T-PRF and compare it with L-PRF. Blood samples were collected from 10 healthy male volunteers. The blood samples were drawn using a syringe. Nine milliliters was transferred to a dry glass tube, and 9 mL was transferred to a titanium tube. Half of each clot (i.e., the blood that was clotted using T-PRF or L-PRF) was processed with a scanning electron microscope (SEM). The other half of each clot was processed for fluorescence microscopy analysis and light microscopy analysis. The T-PRF samples seemed to have a highly organized network with continuous integrity compared to the other L-PRF samples. Histomorphometric analysis showed that T-PRF fibrin network covers larger area than L-PRF fibrin network; also fibrin seemed thicker in the T-PRF samples. This is the first human study to define T-PRF as an autogenous leukocyte- and platelet-rich fibrin product. The platelet activation by titanium seems to offer some high characteristics to T-PRF.

  5. A Novel Platelet Concentrate: Titanium-Prepared Platelet-Rich Fibrin

    Directory of Open Access Journals (Sweden)

    Mustafa Tunalı

    2014-01-01

    Full Text Available We developed a new product called titanium-prepared platelet-rich fibrin (T-PRF. The T-PRF method is based on the hypothesis that titanium may be more effective in activating platelets than the silica activators used with glass tubes in Chouckroun’s leukocyte- and platelet-rich fibrin (L-PRF method. In this study, we aimed to define the structural characteristics of T-PRF and compare it with L-PRF. Blood samples were collected from 10 healthy male volunteers. The blood samples were drawn using a syringe. Nine milliliters was transferred to a dry glass tube, and 9 mL was transferred to a titanium tube. Half of each clot (i.e., the blood that was clotted using T-PRF or L-PRF was processed with a scanning electron microscope (SEM. The other half of each clot was processed for fluorescence microscopy analysis and light microscopy analysis. The T-PRF samples seemed to have a highly organized network with continuous integrity compared to the other L-PRF samples. Histomorphometric analysis showed that T-PRF fibrin network covers larger area than L-PRF fibrin network; also fibrin seemed thicker in the T-PRF samples. This is the first human study to define T-PRF as an autogenous leukocyte- and platelet-rich fibrin product. The platelet activation by titanium seems to offer some high characteristics to T-PRF.

  6. Cell-Based Fabrication of Organic/Inorganic Composite Gel Material

    Directory of Open Access Journals (Sweden)

    Takayoshi Nakano

    2011-01-01

    Full Text Available Biomaterials containing components similar to the native biological tissue would have benefits as an implantable scaffold material. To obtain such biomimetic materials, cells may be great contributors because of their crucial roles in synthetic organics. In addition, the synthesized organics—especially those derived from osteogenic differentiated cells—become a place where mineral crystals nucleate and grow even in vitro. Therefore to fabricate an organic/inorganic composite material, which is similar to the biological osteoid tissue, bone marrow derived mesenchymal stem cells (BMSCs were cultured in a 3D fibrin gel in this study. BMSCs secreted bone-related proteins that enhanced the biomineralization within the gel when the cells were cultured with an osteogenic differentiation medium. The compositions of both synthesized matrices and precipitated minerals in the obtained materials altered depending on the cell culture period. The mineral obtained in the 3D gel showed low crystalline hydroxyapatite. The composite materials also showed excellent osteoconductivity with new bone formation when implanted in mice tibiae. Thus, we demonstrated the contributions of cells for fabricating implantable organic/inorganic composite gel materials and a method for controlling the material composition in the gel. This cell-based material fabrication method would be a novel method to fabricate organic/inorganic composite biomimetic materials for bone tissue engineering.

  7. 21 CFR 864.7300 - Fibrin monomer paracoagulation test.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fibrin monomer paracoagulation test. 864.7300 Section 864.7300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7300 Fibrin...

  8. Platelet glycoprotein VI binds to polymerized fibrin and promotes thrombin generation.

    Science.gov (United States)

    Mammadova-Bach, Elmina; Ollivier, Véronique; Loyau, Stéphane; Schaff, Mathieu; Dumont, Bénédicte; Favier, Rémi; Freyburger, Geneviève; Latger-Cannard, Véronique; Nieswandt, Bernhard; Gachet, Christian; Mangin, Pierre H; Jandrot-Perrus, Martine

    2015-07-30

    Fibrin, the coagulation end product, consolidates the platelet plug at sites of vascular injury and supports the recruitment of circulating platelets. In addition to integrin αIIbβ3, another as-yet-unidentified receptor is thought to mediate platelet interaction with fibrin. Platelet glycoprotein VI (GPVI) interacts with collagen and several other adhesive macromolecules. We evaluated the hypothesis that GPVI could be a functional platelet receptor for fibrin. Calibrated thrombin assays using platelet-rich plasma (PRP) showed that tissue factor-triggered thrombin generation was impaired in GPVI-deficient patients and reduced by the anti-GPVI Fab 9O12. Assays on reconstituted PRP and PRP from fibrinogen-deficient patients revealed a fibrinogen-dependent enhancement of thrombin generation, which relied on functional GPVI. The effect of GPVI was found to depend on fibrin polymerization. A binding assay showed a specific interaction between GPVI-Fc and fibrin, inhibited by the Fab 9O12. This Fab also reduced platelet adhesion to fibrin at low (300 s(-1)) and high (1500 s(-1)) wall shear rates. Platelets adherent to fibrin displayed shape change, exposure of procoagulant phospholipids, and the formation of small clots. When hirudinated blood was perfused at 1500 s(-1) over preformed fibrin-rich clots, the Fab 9O12 decreased the recruitment of platelets by up to 85%. This study identifies GPVI as a platelet receptor for polymerized fibrin with 2 major functions: (1) amplification of thrombin generation and (2) recruitment of circulating platelets to clots. These so-far-unrecognized properties of GPVI confer on it a key role in thrombus growth and stabilization. © 2015 by The American Society of Hematology.

  9. Protective fibrin-sealed plication of the small bowel in recurrent laparotomy.

    Science.gov (United States)

    Holland-Cunz, S; Boelter, A V; Waag, K L

    2003-09-01

    Adhesions after recurrent abdominal operations remain extremely common and are sources of severe morbidity. Fibrin-glued plication of the small gut in a meander-like formation is supposed to guarantee a decreased risk of intestinal obstruction postoperatively. This retrospective study analyses the clinical outcome after recurrent laparotomy in children treated with bowel plication by fibrin sealant. The surgical technique of performing the fibrin-glued plication is rather simple and quick: after taking off all adhesions two to four loops of the small gut are positioned so that they lie side by side. Beginning proximal fibrin [Tissucol fibrin sealant (Baxter)] is applied between the loops; approximately 20-30 s are needed to keep the loops in position until the fibrin dries. This manoeuvre is continued until all of the small gut is fixed in one block. The gut is brought back into the abdominal cavity without loosening the loops. This fixed formation by sero-serosal adhesions or mesenterial plications is supposed to guarantee postoperative free passage. The charts of 60 children who had undergone a fibrin plication of the small bowel between 1991 and 1999 were evaluated. Additionally, questionnaires were sent to all patients, and they were invited for an examination. Sixty patients (38 boys and 22 girls) received a fibrin sealant plication because of recurrent laparotomies with heavily serosal defects or recurrent ileus because of adhesions. The youngest baby was 10 days. Since 23 patients were premature the oldest patient was 11 years old. There were no intraoperative complications attributed to the method. In the postoperative period 7/60 (12%) patients had a recurrent ileus or subileus, leading in three (5%) patients to an early relaparotomy. The fibrin-glued plication of the small bowel decreases the risk of recurrent ileus or subileus considering the high figures in the literature concerning this issue. The time-saving method is very simple and easily feasible

  10. Fibrin promotes proliferation and matrix production of intervertebral disc cells cultured in three-dimensional poly(lactic-co-glycolic acid) scaffold.

    Science.gov (United States)

    Sha'ban, Munirah; Yoon, Sun Jung; Ko, Youn Kyung; Ha, Hyun Jung; Kim, Soon Hee; So, Jung Won; Idrus, Ruszymah Bt Hj; Khang, Gilson

    2008-01-01

    Previously, we have proven that fibrin and poly(lactic-co-glycolic acid) (PLGA) scaffolds facilitate cell proliferation, matrix production and early chondrogenesis of rabbit articular chondrocytes in in vitro and in vivo experiments. In this study, we evaluated the potential of fibrin/PLGA scaffold for intervertebral disc (IVD) tissue engineering using annulus fibrosus (AF) and nucleus pulposus (NP) cells in relation to potential clinical application. PLGA scaffolds were soaked in cells-fibrin suspension and polymerized by dropping thrombin-sodium chloride (CaCl(2)) solution. A PLGA-cell complex without fibrin was used as control. Higher cellular proliferation activity was observed in fibrin/PLGA-seeded AF and NP cells at each time point of 3, 7, 14 and 7 days using the MTT assay. After 3 weeks in vitro incubation, fibrin/PLGA exhibited a firmer gross morphology than PLGA groups. A significant cartilaginous tissue formation was observed in fibrin/PLGA, as proven by the development of cells cluster of various sizes and three-dimensional (3D) cartilaginous histoarchitecture and the presence of proteoglycan-rich matrix and glycosaminoglycan (GAG). The sGAG production measured by 1,9-dimethylmethylene blue (DMMB) assay revealed greater sGAG production in fibrin/PLGA than PLGA group. Immunohistochemical analyses showed expressions of collagen type II, aggrecan core protein and collagen type I genes throughout in vitro culture in both fibrin/PLGA and PLGA. In conclusion, fibrin promotes cell proliferation, stable in vitro tissue morphology, superior cartilaginous tissue formation and sGAG production of AF and NP cells cultured in PLGA scaffold. The 3D porous PLGA scaffold-cell complexes using fibrin can provide a vehicle for delivery of cells to regenerate tissue-engineered IVD tissue.

  11. Fibrin hydrogels to deliver dental stem cells of the apical papilla for regenerative medicine.

    Science.gov (United States)

    Germain, Loïc; De Berdt, Pauline; Vanacker, Julie; Leprince, Julian; Diogenes, Anibal; Jacobs, Damien; Vandermeulen, Gaëlle; Bouzin, Caroline; Préat, Véronique; Dupont-Gillain, Christine; des Rieux, Anne

    2015-01-01

    Evaluation of survival, proliferation and neurodifferentiation of dental stem cells from the apical papilla (SCAP) in fibrin hydrogels. We hypothesized that fibrin composition will influence cell behavior. Modulus, pore and fiber size were measured. SCAP in vitro viability, proliferation and neural differentiation, as well as in vivo proliferation and angiogenesis were studied. Hydrogel moduli were influenced by fibrin formulation but not hydrogel morphology, SCAP in vitro viability and proliferation. In total 60% of SCAP expressed PanNeurofilament in vitro without induction in Fibrinogen50-Thrombin10. SCAP proliferated when implanted in vivo and stimulated host endothelial cell infiltration. Fibrinogen30-Thrombin10 or Thrombin50 would be more favorable to in vitro SCAP viability and in vivo proliferation, while Fibrinogen 50-Thrombin50 would be more adapted to neurodifferentiation.

  12. The disulfide isomerase ERp57 is required for fibrin deposition in vivo.

    Science.gov (United States)

    Zhou, J; Wu, Y; Wang, L; Rauova, L; Hayes, V M; Poncz, M; Essex, D W

    2014-11-01

    ERp57 is required for platelet function; however, whether ERp57 contributes to fibrin generation is unknown. Using an inhibitory anti-ERp57 antibody (mAb1), Pf4-Cre/ERp57(fl/fl) mice, Tie2-Cre/ERp57(fl/fl) mice, and mutants of ERp57, we analyzed the function of ERp57 in laser-induced thrombosis. Fibrin deposition was decreased in Pf4-Cre/ERp57(fl/fl) mice, consistent with a role for platelet ERp57 in fibrin generation. Fibrin deposition was further decreased with infusion of mAb1 and in Tie2-Cre/ERp57(fl/fl) mice, consistent with endothelial cells also contributing to fibrin deposition. Infusion of eptibifatide inhibited platelet and fibrin deposition, confirming a role for platelets in fibrin deposition. Infusion of recombinant ERp57 corrected the defect in fibrin deposition but not platelet accumulation, suggesting a direct effect of ERp57 on coagulation. mAb1 inhibited thrombin generation in vitro, consistent with a requirement for ERp57 in coagulation. Platelet accumulation was decreased to similar extents in Pf4-Cre/ERp57(fl/fl) mice, Tie2-Cre/ERp57(fl/fl) mice and normal mice infused with mAb1. Infusion of completely inactivated ERp57 or ERp57 with a non-functional second active site inhibited fibrin deposition and platelet accumulation, indicating that the isomerase activity of the second active site is required for these processes. ERp57 regulates thrombosis via multiple targets. © 2014 International Society on Thrombosis and Haemostasis.

  13. Equibiaxial cyclic stretch stimulates fibroblasts to rapidly remodel fibrin.

    Science.gov (United States)

    Balestrini, Jenna Leigh; Billiar, Kristen Lawrence

    2006-01-01

    Understanding the effects of the mechanical environment on wound healing is critical for developing more effective treatments to reduce scar formation and contracture. The aim of this study was to investigate the effects of dynamic mechanical stretch on cell-mediated early wound remodeling independent of matrix alignment which obscures more subtle remodeling mechanisms. Cyclic equibiaxial stretch (16% stretch at 0.2 Hz) was applied to fibroblast-populated fibrin gel in vitro wound models for eight days. Compaction, density, tensile strength, and collagen content were quantified as functional measures of remodeling. Stretched samples were approximately ten times stronger, eight-fold more dense, and eight times thinner than statically cultured samples. These changes were accompanied by a 15% increase in net collagen but no significant differences in cell number or viability. When collagen crosslinking was inhibited in stretched samples, the extensibility increased and the strength decreased. The apparent weakening was due to a reduction in compaction rather than a decrease in ability of the tissue to withstand tensile forces. Interestingly, inhibiting collagen crosslinking had no measurable effects on the statically cultured samples. These results indicate that amplified cell-mediated compaction and even a slight addition in collagen content play substantial roles in mechanically induced wound strengthening. These findings increase our understanding of how mechanical forces guide the healing response in skin, and the methods employed in this study may also prove valuable tools for investigating stretch-induced remodeling of other planar connective tissues and for creating mechanically robust engineered tissues.

  14. Fibrin glue in ophthalmology

    Directory of Open Access Journals (Sweden)

    Panda Anita

    2009-01-01

    Full Text Available Suturing is a time consuming task in ophthalmology and suture induced irritation and redness are frequent problems. Postoperative wound infection and corneal graft rejection are examples of possible suture related complications. To prevent these complications, ophthalmic surgeons are switching to sutureless surgery. A number of recent developments have established tissue adhesives like cyanoacrylate glue and fibrin glue as attractive alternatives to sutures. A possible and promising new application for tissue adhesives is to provide a platform for tissue engineering. Currently, tissue glue is being used for conjunctival closure following pterygium and strabismus surgery, forniceal reconstruction surgery, amniotic membrane transplantation, lamellar corneal grafting, closure of corneal perforations and descematoceles, management of conjunctival wound leaks after trabeculectomy, lid surgery, adnexal surgery and as a hemostat to minimise bleeding. The purpose of this review is to discuss the currently available information on fibrin glue.

  15. Does tranexamic acid stabilised fibrin support the osteogenic differentiation of human periosteum derived cells?

    Directory of Open Access Journals (Sweden)

    J Demol

    2011-03-01

    Full Text Available Fibrin sealants have long been used as carrier for osteogenic cells in bone regeneration. However, it has not been demonstrated whether fibrin’s role is limited to delivering cells to the bone defect or whether fibrin enhances osteogenesis. This study investigated fibrin’s influence on the behaviour of human periosteum-derived cells (hPDCs when cultured in vitro under osteogenic conditions in two-dimensional (fibrin substrate and three-dimensional (fibrin carrier environments. Tranexamic acid (TEA was used to reduce fibrin degradation after investigating its effect on hPDCs in monolayer culture on plastic.TEA did not affect proliferation nor calcium deposition of hPDCs under these conditions. Expression profiles of specific osteogenic markers were also maintained within the presence of TEA, apart from reduced alkaline phosphatase (ALP expression (day 14. Compared to plastic, proliferation was upregulated on 2D fibrin substrates with a 220% higher DNA content by day 21. Gene expression was also altered, with significantly (p<0.05 decreased Runx2 (day 7 and ALP (day 14 expression and increased collagen I expression (day 14 and 21. In contrast to plastic, mineralisation was absent on fibrin substrates. Inside fibrin carriers, hPDCs were uniformly distributed. Moderate cell growth and reduced osteogenic marker expression was observed inside fibrin carriers. After 2 weeks, increased cell death was present in the carrier’s centre. In conclusion, fibrin negatively influences osteogenic differentiation, compared to culture plastic, but enhanced proliferation (at least in 2D cultures for hPDCs cultured in osteogenic conditions. TEA maintained the integrity of fibrin-based constructs, with minor effects on the osteogenic differentiation of hPDCs.

  16. Measurements of the Fe3+ diffusion coefficient in Fricke Xylenol gel using optical density measurements

    International Nuclear Information System (INIS)

    Nonato de Oliveira, Lucas; Sampaio, Francisco Glaildo Almeida; Moreira, Marcos Vasques; Almeida, Adelaide de

    2014-01-01

    In Fricke dosimetry, optical density measurements are performed some time after dosimeter irradiation. Values of the diffusion coefficient of Fe 3+ in Fricke Xylenol gel (FXG) are necessary for determining the spatial distribution of the absorbed dose from measurements of the optical density. Five sets of FXG dosimeters, kept at different constant temperatures, were exposed to collimated 6 MV photons. The optical density profile, proportional to the Fe 3+ concentration, at the boundary between irradiated and non-irradiated parts of each dosimeter was measured periodically over a period of 60 h. By comparing the experimental data with a function that accounts for the unobserved initial concentration profile of Fe 3+ in the FXG, we obtained diffusion coefficients 0.30±0.05, 0.40±0.05, 0.50±0.05, 0.60±0.05 and 0.80±0.05 mm 2 /h for the temperatures 283.0±0.5, 286.0±0.5, 289.0±0.5, 292.0±0.5, and 296.0±0.5 K, respectively. The activation energy of Fe 3+ diffusion in the gel, 0.54±0.06 eV, was determined from the temperature dependence of the diffusion coefficients. - Highlights: • A new analytical method to determine diffusion coefficients of ions in gels is proposed. • The method is applied for measurements of the diffusion coefficients of Fe 3+ ions in a Fricke gel dosimeter. • Activation energy of the Fe 3+ ions in the gel was found to be 0.54 ±0.06 eV

  17. Anti-fibrin antibody binding in valvular vegetations and kidney lesions during experimental endocarditis.

    Science.gov (United States)

    Yokota, M; Basi, D L; Herzberg, M C; Meyer, M W

    2001-01-01

    In Streptococcus sanguinis (sanguis) induced experimental endocarditis, we sought evidence that the development of aortic valvular vegetation depends on the availability of fibrin. Endocarditis was induced in New Zealand white rabbits by catheter placement into the left ventricle and inoculation of the bacteria. Fibrin was localized in the developing vegetation with 99mTechnetium (Tc)-labeled anti-fibrin antibody one or three days later. When rabbit anti-fibrin antibody was given intravenously on day 1, the mass of aortic valvular vegetation was significantly reduced at day 3; infusion of non-specific rabbit IgG showed no effect. The 99mTc-labeled anti-fibrin antibody also labeled kidneys that showed macroscopic subcapsular hemorrhage. To learn if the deposition of fibrin in the kidneys was a consequence of endocarditis required a comparison of farm-bred and specific pathogen-free rabbits before and after the induction of endocarditis. Before induction, the kidneys of farm-bred rabbits were labeled, but specific pathogen-free rabbits were free of labeling and signs of macroscopic hemorrhage. After 3 days of endocarditis, kidneys of 10 of 14 specific pathogen-free rabbits labeled with 99mTc-labeled anti-fibrin antibody and showed hemorrhage. Kidney lesions were suggested to be a frequent sequellae of S. sanguinis infective endocarditis. For the first time, fibrin was shown to be required for the continued development of aortic valvular vegetations.

  18. Automatic and quantitative measurement of collagen gel contraction using model-guided segmentation

    Science.gov (United States)

    Chen, Hsin-Chen; Yang, Tai-Hua; Thoreson, Andrew R.; Zhao, Chunfeng; Amadio, Peter C.; Sun, Yung-Nien; Su, Fong-Chin; An, Kai-Nan

    2013-08-01

    Quantitative measurement of collagen gel contraction plays a critical role in the field of tissue engineering because it provides spatial-temporal assessment (e.g., changes of gel area and diameter during the contraction process) reflecting the cell behavior and tissue material properties. So far the assessment of collagen gels relies on manual segmentation, which is time-consuming and suffers from serious intra- and inter-observer variability. In this study, we propose an automatic method combining various image processing techniques to resolve these problems. The proposed method first detects the maximal feasible contraction range of circular references (e.g., culture dish) and avoids the interference of irrelevant objects in the given image. Then, a three-step color conversion strategy is applied to normalize and enhance the contrast between the gel and background. We subsequently introduce a deformable circular model which utilizes regional intensity contrast and circular shape constraint to locate the gel boundary. An adaptive weighting scheme was employed to coordinate the model behavior, so that the proposed system can overcome variations of gel boundary appearances at different contraction stages. Two measurements of collagen gels (i.e., area and diameter) can readily be obtained based on the segmentation results. Experimental results, including 120 gel images for accuracy validation, showed high agreement between the proposed method and manual segmentation with an average dice similarity coefficient larger than 0.95. The results also demonstrated obvious improvement in gel contours obtained by the proposed method over two popular, generic segmentation methods.

  19. Physical determinants of fibrinolysis in single fibrin fibers.

    Directory of Open Access Journals (Sweden)

    Igal Bucay

    Full Text Available Fibrin fibers form the structural backbone of blood clots; fibrinolysis is the process in which plasmin digests fibrin fibers, effectively regulating the size and duration of a clot. To understand blood clot dissolution, the influence of clot structure and fiber properties must be separated from the effects of enzyme kinetics and perfusion rates into clots. Using an inverted optical microscope and fluorescently-labeled fibers suspended between micropatterned ridges, we have directly measured the lysis of individual fibrin fibers. We found that during lysis 64 ± 6% of fibers were transected at one point, but 29 ± 3% of fibers increase in length rather than dissolving or being transected. Thrombin and plasmin dose-response experiments showed that the elongation behavior was independent of plasmin concentration, but was instead dependent on the concentration of thrombin used during fiber polymerization, which correlated inversely with fiber diameter. Thinner fibers were more likely to lyse, while fibers greater than 200 ± 30 nm in diameter were more likely to elongate. Because lysis rates were greatly reduced in elongated fibers, we hypothesize that plasmin activity depends on fiber strain. Using polymer physics- and continuum mechanics-based mathematical models, we show that fibers polymerize in a strained state and that thicker fibers lose their prestrain more rapidly than thinner fibers during lysis, which may explain why thick fibers elongate and thin fibers lyse. These results highlight how subtle differences in the diameter and prestrain of fibers could lead to dramatically different lytic susceptibilities.

  20. Identification of quantitative trait loci for fibrin clot phenotypes: the EuroCLOT study

    DEFF Research Database (Denmark)

    Williams, Frances M K; Carter, Angela M; Kato, Bernet

    2009-01-01

    OBJECTIVE: Fibrin makes up the structural basis of an occlusive arterial thrombus, and variability in fibrin phenotype relates to cardiovascular risk. The aims of the current study from the EU consortium EuroCLOT were to (1) determine the heritability of fibrin phenotypes and (2) identify QTLs as...

  1. Effectiveness of Fibrin Glue in Adherence of Skin Graft.

    Science.gov (United States)

    Reddy, Konda Sireesha; Chittoria, Ravi Kumar; Babu, Preethitha; Marimuthu, Senthil Kumaran; Kumar, Sudhanva Hemanth; Subbarayan, Elan Kumar; Chavan, Vinayak; Mohapatra, Devi Prasad; Sivakumar, Dinesh Kumar; Friji, M T

    2017-01-01

    Graft fixation is important for graft take. Fibrin glue has been proposed as an ideal material, because of its human origin and it provides firm adhesion in seconds or minutes. To evaluate the efficiency of fibrin glue, in increasing the take of skin graft. Assessment includes surgical time taken for graft fixation, haematoma/seroma formation, engraftment and wound closure by day 14. The study is an observational prospective study conducted in the Department of Plastic Surgery, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, from January 2016 to June 2016. Sixteen patients who underwent split skin grafting were assessed during the study period. Fibrin glue was used on the recipient bed before grafting. Better haemostasis and graft adhesion, with a significant reduction of surgical time, were noted. The safety profile of fibrin glue was excellent as indicated by the lack of any related serious adverse experiences. These findings demonstrate that it is safe and effective for attachment of skin grafts, with outcomes at least as good as conventional methods.

  2. Fibrin glue as agent for sealing corneal and conjunctival wound leaks.

    Science.gov (United States)

    Scalcione, C; Ortiz-Vaquerizas, D; Said, D G; Dua, H S

    2018-02-01

    PurposeTo describe a novel use of fibrin glue in managing leaking blebs and leaking wounds following trauma or surgery.MethodsInterventional case series.ResultsWe report eight patients, including three where intra-operative or immediate post-penetrating keratoplasty recalcitrant leaks from the graft-host junction and/or openings created by the needle pass, were noted. All three had thin recipient beds in the sector of leak. This was managed by intra-cameral injection of fibrin glue in the affected quadrant. This stopped the leak and allowed the defect to heal. One patient of Descemets-stripping-endothelial-keratoplasty had leak from the surgical wound, which was also sealed with fibrin glue. Two patients with leaking glaucoma-surgery-related blebs were treated with intra-bleb injection of fibrin glue to stop the leak. One patient with a penetrating corneal injury with a metal wire had a brisk leak upon removal of the wire. This was sealed with fibrin glue. Another patient of chemical burn with spontaneous leaks was managed by glue injection in the perforations. Transient rise of intraocular pressure in one patient with a leaking bleb was the only adverse event recorded.ConclusionThis novel adaptation of the application of fibrin glue can help to deal with persistent intra-operative, post-operative and traumatic aqueous and air leaks.

  3. Fibrin(ogen)olytic activity of bumblebee venom serine protease

    International Nuclear Information System (INIS)

    Qiu Yuling; Choo, Young Moo; Yoon, Hyung Joo; Jia Jingming; Cui Zheng; Wang Dong; Kim, Doh Hoon; Sohn, Hung Dae; Jin, Byung Rae

    2011-01-01

    Bee venom is a rich source of pharmacologically active components; it has been used as an immunotherapy to treat bee venom hypersensitivity, and venom therapy has been applied as an alternative medicine. Here, we present evidence that the serine protease found in bumblebee venom exhibits fibrin(ogen)olytic activity. Compared to honeybee venom, bumblebee venom contains a higher content of serine protease, which is one of its major components. Venom serine proteases from bumblebees did not cross-react with antibodies against the honeybee venom serine protease. We provide functional evidence indicating that bumblebee (Bombus terrestris) venom serine protease (Bt-VSP) acts as a fibrin(ogen)olytic enzyme. Bt-VSP activates prothrombin and directly degrades fibrinogen into fibrin degradation products. However, Bt-VSP is not a plasminogen activator, and its fibrinolytic activity is less than that of plasmin. Taken together, our results define roles for Bt-VSP as a prothrombin activator, a thrombin-like protease, and a plasmin-like protease. These findings offer significant insight into the allergic reaction sequence that is initiated by bee venom serine protease and its potential usefulness as a clinical agent in the field of hemostasis and thrombosis. - Graphical abstract: Display Omitted Highlights: → Bumblebee venom serine protease (Bt-VSP) is a fibrin(ogen)olytic enzyme. → Bt-VSP activates prothrombin. → Bt-VSP directly degrades fibrinogen into fibrin degradation products. → Bt-VSP is a hemostatically active protein that is a potent clinical agent.

  4. Chylothorax after mediastinal ganglioneuroma resection treated with fibrin sealant patch: a case report

    Science.gov (United States)

    Chiarelli, Marco; Achilli, Pietro; Guttadauro, Angelo; Vertemati, Giuseppe; Terragni, Sabina; De Simone, Matilde

    2017-01-01

    Chylothorax is a severe condition resulting from the accumulation of chyle into the pleural space. We report the treatment of postoperative chylothorax after resection of mediastinal ganglioneuroma in a 17-year-old boy. Since conservative measures were not effective, we performed direct ligation of lymphatic vessels and pleurodesis. At subsequent surgical re-exploration for persisting chylothorax, accurate inspection of pleural cavity revealed residual chyle leakage. Fibrin sealant patches (TachoSil®) were placed over the source of leak with complete resolution of chylous effusion. To our knowledge, this is the first report of postoperative chylothorax successfully treated by the use of a fibrin sealant patch. PMID:29221335

  5. Polymer gel dosimetry for synchrotron stereotactic radiotherapy and iodine dose-enhancement measurements

    International Nuclear Information System (INIS)

    Boudou, C; Tropres, I; Rousseau, J; Lamalle, L; Adam, J F; Esteve, F; Elleaume, H

    2007-01-01

    Synchrotron stereotactic radiotherapy (SSR) is a radiotherapy technique that makes use of the interactions of monochromatic low energy x-rays with high atomic number (Z) elements. An important dose-enhancement can be obtained if the target volume has been loaded with a sufficient amount of a high-Z element, such as iodine. In this study, we compare experimental dose measurements, obtained with normoxic polymer gel (nPAG), with Monte Carlo computations. Gels were irradiated within an anthropomorphic head phantom and were read out by magnetic resonance imaging. The dose-enhancement due to the presence of iodine in the gel (iodine concentration: 5 and 10 mg ml -1 ) was measured at two radiation energies (35 and 80 keV) and was compared to the calculated factors. nPAG dosimetry was shown to be efficient for measuring the sharp dose gradients produced by SSR. The agreement between 3D gel dosimetry and calculated dose distributions was found to be within 4% of the dose difference criterion and a distance to agreement of 2.1 mm for 80% of the voxels. Polymer gel doped with iodine exhibited higher sensitivity, in good agreement with the calculated iodine-dose enhancement. We demonstrate in this preliminary study that iodine-doped nPAG could be used for measuring in situ dose distributions for iodine-enhanced SSR treatment

  6. Microneural anastomosis with fibrin glue : an experimental study.

    OpenAIRE

    Suri A; Mehta V; Sarkar C

    2002-01-01

    An experimental study was designed to compare the histological analysis of nerve anastomosis with 10-0 microsurgical sutures and fibrin adhesive. Wistar albino rats′ sciatic nerves were transected and repaired either with fibrin adhesive-Beriplast P (M/s Centeon-Cadila Health Care) or with 10-0 monofilament microsutures. Histological assessment was performed at 10, 20, 30, 60 and 90 days after surgery. Functional recovery of the sciatic nerves started at two months and was near normal ...

  7. Normal stresses in semiflexible polymer hydrogels

    Science.gov (United States)

    Vahabi, M.; Vos, Bart E.; de Cagny, Henri C. G.; Bonn, Daniel; Koenderink, Gijsje H.; MacKintosh, F. C.

    2018-03-01

    Biopolymer gels such as fibrin and collagen networks are known to develop tensile axial stress when subject to torsion. This negative normal stress is opposite to the classical Poynting effect observed for most elastic solids including synthetic polymer gels, where torsion provokes a positive normal stress. As shown recently, this anomalous behavior in fibrin gels depends on the open, porous network structure of biopolymer gels, which facilitates interstitial fluid flow during shear and can be described by a phenomenological two-fluid model with viscous coupling between network and solvent. Here we extend this model and develop a microscopic model for the individual diagonal components of the stress tensor that determine the axial response of semiflexible polymer hydrogels. This microscopic model predicts that the magnitude of these stress components depends inversely on the characteristic strain for the onset of nonlinear shear stress, which we confirm experimentally by shear rheometry on fibrin gels. Moreover, our model predicts a transient behavior of the normal stress, which is in excellent agreement with the full time-dependent normal stress we measure.

  8. Finger-Shaped GelForce: Sensor for Measuring Surface Traction Fields for Robotic Hand.

    Science.gov (United States)

    Sato, K; Kamiyama, K; Kawakami, N; Tachi, S

    2010-01-01

    It is believed that the use of haptic sensors to measure the magnitude, direction, and distribution of a force will enable a robotic hand to perform dexterous operations. Therefore, we develop a new type of finger-shaped haptic sensor using GelForce technology. GelForce is a vision-based sensor that can be used to measure the distribution of force vectors, or surface traction fields. The simple structure of the GelForce enables us to develop a compact finger-shaped GelForce for the robotic hand. GelForce that is developed on the basis of an elastic theory can be used to calculate surface traction fields using a conversion equation. However, this conversion equation cannot be analytically solved when the elastic body of the sensor has a complicated shape such as the shape of a finger. Therefore, we propose an observational method and construct a prototype of the finger-shaped GelForce. By using this prototype, we evaluate the basic performance of the finger-shaped GelForce. Then, we conduct a field test by performing grasping operations using a robotic hand. The results of this test show that using the observational method, the finger-shaped GelForce can be successfully used in a robotic hand.

  9. Source of fibrin/fibrinogen degradation products in the CSF after subarachnoid hemorrhage

    NARCIS (Netherlands)

    Vermeulen, M.; van Vliet, H. H.; Lindsay, K. W.; Hijdra, A.; van Gijn, J.

    1985-01-01

    In 48 patients with a subarachnoid hemorrhage, levels of fibrin/fibrinogen degradation products (FDP's), total protein, and plasminogen were measured in the cerebrospinal fluid (CSF) between Days 9 and 15 after the bleed. Of these 48 patients, 22 received tranexamic acid. Despite a significant

  10. Reconstruction of living bilayer human skin equivalent utilizing human fibrin as a scaffold.

    Science.gov (United States)

    Mazlyzam, A L; Aminuddin, B S; Fuzina, N H; Norhayati, M M; Fauziah, O; Isa, M R; Saim, L; Ruszymah, B H I

    2007-05-01

    Our aim of this study was to develop a new methodology for constructing a bilayer human skin equivalent to create a more clinical compliance skin graft composite for the treatment of various skin defects. We utilized human plasma derived fibrin as the scaffold for the development of a living bilayer human skin equivalent: fibrin-fibroblast and fibrin-keratinocyte (B-FF/FK SE). Skin cells from six consented patients were culture-expanded to passage 1. For B-FF/FK SE formation, human fibroblasts were embedded in human fibrin matrix and subsequently another layer of human keratinocytes in human fibrin matrix was stacked on top. The B-FF/FK SE was then transplanted to athymic mice model for 4 weeks to evaluate its regeneration and clinical performance. The in vivo B-FF/FK SE has similar properties as native human skin by histological analysis and expression of basal Keratin 14 gene in the epidermal layer and Collagen type I gene in the dermal layer. Electron microscopy analysis of in vivo B-FF/FK SE showed well-formed and continuous epidermal-dermal junction. We have successfully developed a technique to engineer living bilayer human skin equivalent using human fibrin matrix. The utilization of culture-expanded human skin cells and fibrin matrix from human blood will allow a fully autologous human skin equivalent construction.

  11. Crestal Approach to Sinus Floor Elevation for Atrophic Maxilla Using Platelet-Rich Fibrin as the Only Grafting Material: A 1-Year Prospective Study.

    Science.gov (United States)

    Kanayama, Takeo; Horii, Koichiro; Senga, Yasuko; Shibuya, Yasuyuki

    2016-02-01

    Platelet-rich fibrin (PRF) has been recently used as the sole grafting material in sinus floor elevation procedures. The aim of this prospective study was to measure the bone gain around the dental implant after using the crestal approach to sinus floor elevation using platelet-rich fibrin as the only grafting material in atrophic posterior maxillae with residual bone height platelet-rich fibrin promoted endosinus bone gain when used as the grafting material in the crestal approach to sinus floor elevation.

  12. Effect of the exothermal polymerization reaction on polymer gel dosimetric measurements

    International Nuclear Information System (INIS)

    Sedaghat, Mahbod; Bujold, Rachel; Lepage, Martin

    2010-01-01

    Discrepancies in polymer gel dosimetric measurements have been observed between containers of different sizes receiving the same radiation dose. We hypothesized that these deviations are caused by a change in the rate of polymerization due to internal heat increase in the gel containers resulting from the exothermic polymerization of monomers. Here, we test this hypothesis in a polyacrylamide gel dosimeter by recording the temperature in glass phantoms of different sizes during and after irradiation. The dose response of the samples was determined with magnetic resonance imaging. The difference of R 2 values along the depth of the containers was below ±1%. We discuss that this small difference can be attributed to variations in the rate of gelatin cooling during manufacture rather than to the measured heat increase during irradiation.

  13. Effects of fibrin, thrombin, and blood on breast capsule formation in a preclinical model.

    Science.gov (United States)

    Marques, Marisa; Brown, Spencer A; Cordeiro, Natália D S; Rodrigues-Pereira, Pedro; Cobrado, M Luís; Morales-Helguera, Aliuska; Lima, Nuno; Luís, André; Mendanha, Mário; Gonçalves-Rodrigues, Acácio; Amarante, José

    2011-03-01

    The root cause of capsular contracture (CC) associated with breast implants is unknown. Recent evidence points to the possible role of fibrin and bacteria in CC formation. The authors sought to determine whether fibrin, thrombin, and blood modulated the histological and microbiological outcomes of breast implant capsule formation in a rabbit model. The authors carried out a case-control study to assess the influence of fibrin, thrombin, and blood on capsule wound healing in a rabbit model. Eighteen New Zealand white rabbits received four tissue expanders. One expander acted as a control, whereas the other expander pockets received one of the following: fibrin glue, rabbit blood, or thrombin sealant. Intracapsular pressure/volume curves were compared among the groups, and histological and microbiological evaluations were performed (capsules, tissue expanders, rabbit skin, and air). The rabbits were euthanized at two or four weeks. At four weeks, the fibrin and thrombin expanders demonstrated significantly decreased intracapsular pressure compared to the control group. In the control and fibrin groups, mixed inflammation correlated with decreased intracapsular pressure, whereas mononuclear inflammation correlated with increased intracapsular pressure. The predominant isolate in the capsules, tissue expanders, and rabbit skin was coagulase-negative staphylococci. For fibrin and thrombin, both cultures that showed an organism other than staphylococci and cultures that were negative were associated with decreased intracapsular pressure, whereas cultures positive for staphylococci were associated with increased intracapsular pressure. Fibrin application during breast implantation may reduce rates of CC, but the presence of staphylococci is associated with increased capsule pressure even in the presence of fibrin, so care should be taken to avoid bacterial contamination.

  14. The economic impact of poor sample quality in clinical chemistry laboratories: results from a global survey.

    Science.gov (United States)

    Erdal, Erik P; Mitra, Debanjali; Khangulov, Victor S; Church, Stephen; Plokhoy, Elizabeth

    2017-03-01

    Background Despite advances in clinical chemistry testing, poor blood sample quality continues to impact laboratory operations and the quality of results. While previous studies have identified the preanalytical causes of lower sample quality, few studies have examined the economic impact of poor sample quality on the laboratory. Specifically, the costs associated with workarounds related to fibrin and gel contaminants remain largely unexplored. Methods A quantitative survey of clinical chemistry laboratory stakeholders across 10 international regions, including countries in North America, Europe and Oceania, was conducted to examine current blood sample testing practices, sample quality issues and practices to remediate poor sample quality. Survey data were used to estimate costs incurred by laboratories to mitigate sample quality issues. Results Responses from 164 participants were included in the analysis, which was focused on three specific issues: fibrin strands, fibrin masses and gel globules. Fibrin strands were the most commonly reported issue, with an overall incidence rate of ∼3%. Further, 65% of respondents indicated that these issues contribute to analyzer probe clogging, and the majority of laboratories had visual inspection and manual remediation practices in place to address fibrin- and gel-related quality problems (55% and 70%, respectively). Probe maintenance/replacement, visual inspection and manual remediation were estimated to carry significant costs for the laboratories surveyed. Annual cost associated with lower sample quality and remediation related to fibrin and/or gel globules for an average US laboratory was estimated to be $100,247. Conclusions Measures to improve blood sample quality present an important step towards improved laboratory operations.

  15. Fibrin glue as a protective tool for microanastomoses in limb reconstructive surgery

    Directory of Open Access Journals (Sweden)

    Langer, Stefan

    2015-12-01

    Full Text Available Aim: Fibrin glue becomes a more and more routinely used tool for stabilization of microanastomoses and nerve repair. This paper summarizes the technical properties and advantages of its use in a wide variety of microsurgical contexts, and includes an exemplary limb reconstructive case.Patients and methods: A total of 131 patients who had undergone elective and emergency microsurgery mainly of the limbs were retrospectively analyzed, as was the use of free flaps.Results: The use of fibrin glue allows for proper positioning of anastomoses and repaired nerves. No torsion of the pedicle could be seen. The flap survival rated >94%. The fibrin glue could stay in place in >99%. In the rare case of revision, the fibrin glue could easily be removed without damaging the region of the microanastomosis.Conclusion: Fibrin glue should not be used to repair insufficient, i.e., leaking anastomoses, but it does protect the site of anastomosis from tissue and fluid pressure. It prevents the pedickle from torsion and its use facilitates relocation of the microanastomoses in cases of revision surgery.

  16. Fibrin accumulation secondary to loss of plasmin-mediated fibrinolysis drives inflammatory osteoporosis in mice.

    Science.gov (United States)

    Cole, Heather A; Ohba, Tetsuro; Nyman, Jeffry S; Hirotaka, Haro; Cates, Justin M M; Flick, Matthew J; Degen, Jay L; Schoenecker, Jonathan G

    2014-08-01

    Osteoporosis is a skeletal disorder characterized by low bone mass and increased bone fragility associated with aging, menopause, smoking, obesity, or diabetes. Persistent inflammation has been identified as an instigating factor in progressive bone loss. In addition to the role of fibrin in coagulation, inordinate fibrin deposition within a tissue matrix results in increased local inflammation. Given that fibrin accumulation is a hallmark of osteoporosis-related comorbidities, we undertook this study to test the hypothesis that persistent fibrin deposition causes inflammatory osteoporosis. Multiple imaging modalities, bone integrity metrics, and histologic analyses were employed to evaluate skeletal derangements in relation to fibrin deposition, circulating fibrinogen levels, and systemic markers of inflammation in mice that were plasminogen deficient and in plasminogen-deficient mice that were concomitantly either fibrinogen deficient or carrying a mutant form of fibrinogen lacking the αM β2 binding motif. Mice generated with a genetic deficit in the key fibrinolytic protease, plasmin, uniformly developed severe osteoporosis. Furthermore, the development of osteoporosis was fibrin(ogen) dependent, and the derangements in the bone remodeling unit were mechanistically tied to fibrin(ogen)-mediated activation of osteoclasts via activation of the leukocyte integrin receptor αM β2 on monocytes and secondary stimulation of osteoblasts by RANKL. Notably, the genetic elimination of fibrin(ogen) or the expression of a mutant form of fibrinogen retaining clotting function but lacking the αM β2 binding motif prevented the degenerative skeletal phenotypes, resulting in normal local and systemic cytokine levels. Taken together, these data reveal for the first time that fibrin promotes inflammation-driven systemic osteoporosis, which suggests a novel association between hemostasis, inflammation, and bone biology. Copyright © 2014 by the American College of Rheumatology.

  17. Bioactivity and stability of endogenous fibrogenic factors in platelet-rich fibrin

    DEFF Research Database (Denmark)

    Lundquist, R.; Dziegiel, M.H.; Agren, M.S.

    2008-01-01

    Platelet-rich fibrin (PRF) is an autologous fibrin sealant (FS) enriched with a platelet concentrate (> 1,000,000 platelets/microL) produced by the automated Vivostat system and used to enhance wound healing. The effects of PRF were compared with supernatant from thrombin-activated platelet conce...

  18. The use of 125I-labelled fibrinogen for determination of fibrin trapping in the lungs in patients developing the microembolism syndrome

    International Nuclear Information System (INIS)

    Busch, C.; Dahlgren, S.; Jakobson, S.; Jung, B.; Modig, J.; Saldeen, T.

    1975-01-01

    The microembolism syndrome occurred in four patients out of a series of 15 patients with multiple injuries who were considered to run a risk of developing this syndrome. These four patients showed signs of fibrin trapping in the lungs, as demonstrated by the use of 125 I-labelled fibrinogen and external detection over the lungs. It is, therefore, considered that this method can be used for diagnosing the microembolism syndrome. The fibrin trapping occurred at the onset of the progressive respiratory insufficiency. The time relation between the uptake of fibrin and the onset of the progressive respiratory insufficiency supports the theory af a causal connection between fibrin and pulmonary damage. Measurements of different coagulation and fibrinolysis factors in the blood were not able to discriminate between patients who developed the microembolism syndrome and those who did not. (author)

  19. Use of normoxic polymer gel dosimeters for measuring diagnostic doses on CT scanners

    International Nuclear Information System (INIS)

    Hill, B; Venning, A J; Baldock, C

    2004-01-01

    X-ray CT has been used to evaluate polymer gel dosimeters for dose response in the therapeutic dose range. This method of polymer gel dosimeter evaluation has been shown to be useful for instance in the comparison of complex sterotactic field distributions with treatment plans. Image averaging and subtraction techniques are used for noise reduction in polymer gel dosimeters resulting in the delivery of several CT slices across the polymer gel dosimeters. It was a logical progression to evaluate normoxic polymer gel dosimeters with optimized CT scanning protocols. During these investigations it was found that unirradiated regions in irradiated normoxic polymer gel dosimetry phantoms polymerised possibly as a result of the evaluation using CT. This prompted an investigation of the CT diagnostic dose response of the normoxic polymer gel dosimeter in order to determine the dose contribution when evaluated using a CT scanner. Having established that there was an effect on the normoxic polymer gel dosimeter when evaluating with a CT scanner the suitability of these gels in the determination of CT diagnostic dose measurement was further investigated

  20. Radiolabelled anti-human fibrin antibody: a new thrombus-detecting agent

    International Nuclear Information System (INIS)

    Bosnjakovic, V.; Jankovic, B.D.; Horvat, J.; Cvoric, J.

    1977-01-01

    Rabbit anti-human fibrin globulin (A.F.G.) was labelled with iodine ( 131 I) and used as a thrombus-detecting agent. 131 I-A.F.G. labelled thrombi were displayed by means of a gamma scintillation camera. Normal subjects and patients with thrombo-phlebitis of legs, acute fibrin depositions other than thrombi, and chronic varicosities were examined. The 131 I-A.F.G. technique detected both formed thrombi and those that were forming and could discriminate between acute thrombosis and chronic varicosities. Thrombo-phlebitis and extravascular fibrin depositions were best demonstrated between 24 and 72 hours after 131 I-A.F.G. injection. Radiolabelled A.F.G. in normal veins and chronic varicosities was best displayed within 6 hours of injection. (author)

  1. Fibrin d-dimer concentration, deep vein thrombosis symptom duration, and venous thrombus volume.

    Science.gov (United States)

    Kurklinsky, Andrew K; Kalsi, Henna; Wysokinski, Waldemar E; Mauck, Karen F; Bhagra, Anjali; Havyer, Rachel D; Thompson, Carrie A; Hayes, Sharonne N; McBane, Robert D

    2011-04-01

    To determine the relationship between fibrin D-dimer levels, symptom duration, and thrombus volume, consecutive patients with incident deep venous thrombosis (DVT) were evaluated. In a cross-sectional study design, patient symptom onset was determined by careful patient questioning. Venous thrombosis was confirmed by compression duplex ultrasonography. Thrombus volume was estimated based on patient's femur length using a forensic anthropology method. Fibrin D-dimer was measured by latex immunoassay. 72 consecutive patients with confirmed leg DVT agreed to participate. The median symptom duration at the time of diagnosis was 10 days. The median D-dimer concentration was 1050 ng/dL. The median thrombus volume was 12.92 cm(3). D-Dimer levels correlated with estimated thrombus volume (P venous thrombosis and correlates with thrombus volume.

  2. Comparison of two fibrin glues in anastomoses and skin closure.

    Science.gov (United States)

    Park, W; Kim, W H; Lee, C H; Kim, D Y; Choi, J H; Huh, J W; Sung, H M; Kim, I S; Kweon, O K

    2002-09-01

    To control intra-operative haemorrhage, fibrin glues are preferred by many surgeons because of their biological advantages and convenience of application. Manufacturers have developed a few kinds of fibrin glues with a little difference in their composition. This study was to compare the effectiveness of two commercially available fibrin glues; Greenplast (Green Cross P. D. Company, Yongin, Korea) and Tisseel (Baxter-Immuno AG, Vienna, Austria). They were applied experimentally to several kinds of surgery in dogs - renal vessel anastomosis, partial splenectomy, intestinal anastomosis and incision skin wound - and evaluated for their haemostatic and adhesive effects. When the two glues were applied in renal vessel anastomosis, the amount of haemorrhage in artery and vein decreased significantly. They also decreased the haemorrhage in partial splenectomy. At 10 min after application of the glues to an incision skin wound, the tensile strengths developed were significantly higher than that of control. The present study indicates that two-component fibrin glues have a haemostatic effect as a mechanical barrier in renal vessel anastomosis and an adhesive effect in the early stage of incision skin wound closure, and the two glues have similar effects with no complications.

  3. Clinical evaluations of complete autologous fibrin glue, produced by the CryoSeal® FS system, and polyglycolic acid sheets as wound coverings after oral surgery.

    Science.gov (United States)

    Kouketsu, Atsumu; Nogami, Shinnosuke; Yamada-Fujiwara, Minami; Nagai, Hirokazu; Yamauchi, Kensuke; Mori, Shiro; Miyashita, Hitoshi; Kawai, Tadashi; Matsui, Aritsune; Kataoka, Yoshihiro; Satomi, Norihisa; Ezoe, Yushi; Abe, Satoko; Takeda, Yuri; Tone, Takeshi; Hirayama, Bunnichi; Kurobane, Tsuyoshi; Tashiro, Kazuki; Yanagisawa, Yuta; Takahashi, Tetsu

    2017-09-01

    The CryoSeal ® FS System has been recently introduced as an automated device for the production of complete fibrin glue from autologous plasma, rather than from pool allogenic or cattle blood, to prevent viral infection and allergic reaction. We evaluated the effectiveness of complete autologous fibrin glue and polyglycolic acid (PGA) sheet wound coverings in mucosa defect oral surgery. Postoperative pain, scar contracture, ingestion, tongue dyskinesia, and postoperative bleeding were evaluated in 12 patients who underwent oral (including the tongue) mucosa excision, and received a PGA sheet and an autologous fibrin glue covering. They were compared with 12 patients who received a PGA sheet and commercial allogenic fibrin glue. All cases in the complete autologous fibrin glue group demonstrated good wound healing without complications such as local infection or incomplete cure. All evaluated clinical measures in this group were similar or superior to the commercial allogenic fibrin glue group. Coagulation and adhesion quality achieved with this method was comparable to that with a PGA sheet and commercial fibrin glue. Covering oral surgery wounds with complete autologous fibrin glue produced by an automated device was convenient, safe, and reduced the risk of viral infection and allergic reaction associated with conventional techniques. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  4. USAGE OF MONOCLONAL ANTIBODIES FOR DETERMINATION OF LOCALIZATION OF ANTIGENIC DETERMINANTS AND FIBRIN POLYMERIZATION SITES WITHIN FIBRINOGEN AND FIBRIN MOLECULES AND THEIR APPLICATION IN TEST--SYSTEMS FOR DIAGNOSTICS AND THE THREAT OF THROMBUS FORMATION

    Directory of Open Access Journals (Sweden)

    E. V. Lugovskoi

    2013-08-01

    Full Text Available It was shown by monoclonal antibodies that B?N-region of fibrin desA molecule (B?1-53 comprises the polymerization site including the peptide bond B?14-15. This site participates in the second stage of fibrin polymerization — lateral association of protofibrils. In the B?15-53 fragment was also found the site called «C», which together with the site «A» participate in the first stage of polymerization — the protofibrils formation. The model of the primary intermolecular interaction of fibrin was designed. It was found by monoclonal antibodies II-4d the site («c» in the N-terminal half of ? chain of the fibrin D-region. This site participates in the protofibrils formation and is complement to site «C» as we assume. We have discovered two neoantigenic determinants. One of these determinants exposes within the coiledcoil fragment B?126-135 of fibrin as a result of fibrinopeptide A splitting off from fibrinogen by thrombin. The structural rearrangements discovered in this site of the fibrin molecule are necessary for the following protofibrils lateral association. The second neoantigenic determinant is localized in the fragment B?134-190 of D-dimer formed after plasmin degradation of fibrin stabilized by FXIIIa. We have obtained the fibrin-specific monoclonal antibodie FnI-3C to the first determinant and D-dimer-specific mAb III-3b to the second one. Three monoclonal antibodies were obtained against the ?C-region of fibrin(ogen molecule. It has been experimentally shown by of one of them that ?C-domains is connected with the fibrinopeptides B in fibrinogen and fibrin desA molecules, but removes from the core of the molecules after fibrinopeptides B splitting off by thrombin. Two other monoclonal antibodies specifically inhibit the fibrin polymerization by blocking two unknown polymerization sites within the ?C-region. The test-systems for the soluble fibrin and D-dimer quantification in human blood plasma were designed on the basis of

  5. Vivostat®: an autologous fibrin sealant as useful adjunct in endoscopic transnasal CSF-leak repair.

    Science.gov (United States)

    Tomazic, Peter Valentin; Edlinger, Stefan; Gellner, Verena; Koele, Wolfgang; Gerstenberger, Claus; Braun, Hannes; Mokry, Michael; Stammberger, Heinz

    2015-06-01

    The benefit of fibrin glue for reduction of postoperative CSF-leaks after endoscopic skull base surgery is not clearly evident in literature. However, its use is supposed to be beneficial in fixing grafting material. As of today there is no specific data available for otolaryngological procedures. A retrospective data analysis at a tertiary care referral center on 73 patients treated endoscopically transnasally for CSF-leaks at the ENT-department Graz between 2009 and 2012 was performed. Primary closure rate between conventional fibrin glue and autologous fibrin glue were analyzed. The Vivostat(®) system was used in 33 CSF-leak closures and in 40 cases conventional fibrin glue was used. Comparing the two methods the primary closure rate using the autologous Vivostat(®) system was 75.8 and 85.0 % with conventional fibrin glue. The secondary closure the rates were 90.9 % with Vivostat(®) 92.5 % with conventional fibrin glue. The Vivosat(®) system is a useful adjunct in endoscopic CSF-leak closure. Its advantages over conventional fibrin glue are its application system for fixation of grafting material particularly in underlay techniques. Despite this advantage it cannot replace grafting material or is a substitute for proper endoscopic closure which is reflected by the closure rates.

  6. Effect of dextran on platelet activation by polymerizing fibrin.

    OpenAIRE

    Ts'ao, C. H.; Krajewski, D. V.

    1982-01-01

    Dextran has been shown to alter the mechanical properties and lysability of fibrin. The present study was undertaken to determine whether it would also influence the ability of polymerizing fibrin to activate platelets. Human fibrinogen, with or without the presence of dextran, was incubated with either human thrombin or reptilase at 37 C. Macroscopically evident fibrils first appeared at 7 1/2 to 8 minutes in fibrinogen solution not containing dextran and at 2 1/2 to 3 minutes in solution co...

  7. A Novel Platelet Concentrate: Titanium-Prepared Platelet-Rich Fibrin

    OpenAIRE

    Mustafa Tunalı; Hakan Özdemir; Zafer Küçükodacı; Serhan Akman; Emre Yaprak; Hülya Toker; Erhan Fıratlı

    2014-01-01

    We developed a new product called titanium-prepared platelet-rich fibrin (T-PRF). The T-PRF method is based on the hypothesis that titanium may be more effective in activating platelets than the silica activators used with glass tubes in Chouckroun's leukocyte- and platelet-rich fibrin (L-PRF) method. In this study, we aimed to define the structural characteristics of T-PRF and compare it with L-PRF. Blood samples were collected from 10 healthy male volunteers. The blood samples were drawn us...

  8. Topical tissue plasminogen activator appears ineffective for the clearance of intraocular fibrin.

    Science.gov (United States)

    Zwaan, J; Latimer, W B

    1998-06-01

    To determine the efficacy of topical tissue plasminogen activator (tPA) for the resolution of postoperative or inflammatory intraocular fibrinous exudates. Each treatment consisted of drops of 1 mg/ml tPA given 9 times 5 minutes apart. Records were reviewed and the results at 24 and 48 hours were recorded. Sixty-two patients had a total of 94 treatments. Fibrin exudates following intraocular surgery in 34 patients were treated 44 times. In 6 patients there was a positive result. Fibrin associated with intraocular infection was treated in 9 patients. None showed clear improvement. Nineteen patients had a total of 34 treatments for poorly controlled intraocular pressure (IOP) after glaucoma surgery. Five patients showed adequate control of the IOP, 12 did not change, and 2 had a questionable improvement. Eleven patients had adequate IOP control after additional treatment. Seven required suture lysis, 2 ab interno bleb revision, and 2 YAG capsulotomy or iridotomy to reduce the IOP to an acceptable level. Within the limits of this retrospective study and taking into account that fibrin may resolve spontaneously, it appears that topical tPA drops are not effective for the liquefaction of intraocular fibrin after surgery or in association with intraocular inflammation. They did not improve IOP control after glaucoma surgery.

  9. Does Fibrin Sealant Reduce Seroma after Immediate Breast Reconstruction Utilizing a Latissimus Dorsi Myocutaneous Flap?

    Directory of Open Access Journals (Sweden)

    Han Gyu Cha

    2012-09-01

    Full Text Available Background The most common complication of latissimus dorsi myocutaneous flap in breastreconstruction is seroma formation in the back. Many clinical studies have shown that fibrinsealant reduces seroma formation. We investigated any statistically significant differences inpostoperative drainage and seroma formation when utilizing the fibrin sealant on the site ofthe latissimus dorsi myocutaneous flap harvested for immediate breast reconstruction afterskin-sparing partial mastectomy.Methods A total of 46 patients underwent immediate breast reconstruction utilizing alatissimus dorsi myocutaneous island flap. Of those, 23 patients underwent the procedurewithout fibrin sealant and the other 23 were administered the fibrin sealant. All flaps wereelevated with manual dissection by the same surgeon and were analyzed to evaluate thepotential benefits of the fibrin sealant. The correlation analysis and Mann-Whitney U testwere used for analyzing the drainage volume according to age, weight of the breast specimen,and body mass index.Results Although not statistically significant, the cumulative drainage fluid volume was higherin the control group until postoperative day 2 (530.1 mL compared to 502.3 mL, but thefibrin sealant group showed more drainage beginning on postoperative day 3. The donor sitecomparisons showed the fibrin sealant group had more drainage beginning on postoperativeday 3 and the drain was removed 1 day earlier in the control group.Conclusions The use of fibrin sealant resulted in no reduction of seroma formation. Becausethe benefits of the fibrin sealant are not clear, the use of fibrin sealant must be fully discussedwith patients before its use as a part of informed consent.

  10. Antimicrobial drugs encapsulated in fibrin nanoparticles for treating microbial infested wounds.

    Science.gov (United States)

    Alphonsa, B Maria; Sudheesh Kumar, P T; Praveen, G; Biswas, Raja; Chennazhi, K P; Jayakumar, R

    2014-05-01

    In vitro evaluation of antibacterial and antifungal drugs encapsulated fibrin nanoparticles to prove their potential prospect of using these nanocomponent for effective treatment of microbial infested wounds. Surfactant-free oil-in-water emulsification-diffusion method was adopted to encapsulate 1 mg/ml each of antimicrobial drugs (Ciprofloxacin and Fluconazole) in 4 ml of aqueous fibrinogen suspension and subsequent thrombin mediated cross linking to synthesize drug loaded fibrin nanoparticles. Ciprofloxacin loaded fibrin nanoparticles (CFNPs) showed size range of 253 ± 6 nm whereas that of Fluconazole loaded fibrin nanoparticles (FFNPs) was 260 ± 10 nm. Physico chemical characterizations revealed the firm integration of antimicrobial drugs within fibrin nanoparticles. Drug release studies performed at physiological pH 7.4 showed a release of 16% ciprofloxacin and 8% of fluconazole while as the release of ciprofloxacin at alkaline pH 8.5, was 48% and that of fluconazole was 37%. The antimicrobial activity evaluations of both drug loaded systems independently showed good antibacterial activity against Escherichia coli (E.coli), Staphylococcus aureus (S. aureus) and antifungal activity against Candida albicans (C. albicans). The in vitro toxicity of the prepared drug loaded nanoparticles were further analyzed using Human dermal fibroblast cells (HDF) and showed adequate cell viability. The efficacies of both CFNPs and FFNPs for sustained delivery of encapsulated anti microbial drugs were evaluated in vitro suggesting its potential use for treating microbial infested wounds (diabetic foot ulcer).

  11. Study of the fibrinogen - fibrin transformation kinetics and modifications caused to this reaction by irradiation (X rays) of the fibrinogen solution

    International Nuclear Information System (INIS)

    Hollard, D.; Suscillon, M.; Marcille, G.; Rambaud, F.; Baloyan, M.

    1966-01-01

    The authors present a spectrophotometric method for studying the transformation fibrinogen - fibrin. This method has the advantage of drawing immediately in graph form the three, phases of this transformation: proteolysis or monomerization; polymerisation; clot stabilization. It is a simple, faithful and easily reproductive technic. Owing to this method, they studied modifications of this transformation due to irradiation of fibrinogen solution. Low doses (90 000 R/mn) prevent transverse polymerisation. To upper doses (180 000 R and more), the action of thrombin on fibrinogen does not give an organised clot but a lacteous and fragile gel. There is not here a coagulation in the physiological understanding. (author) [fr

  12. Comparative Study of Fibrin Sealent versus Use of Tackers in Inguinal Hernia Repair

    Directory of Open Access Journals (Sweden)

    Wasim Qadir Kar

    2015-09-01

    Full Text Available Purpose: To determine role and benefit of fibrin glue over tackers for mesh fixation in laparoscopic inguinal hernia repair. Backgroud: Mesh fixation by tackers may lead to many complications peroperatively like bleeding, increased hospital stay and overall more cost and later on chronic groin pain. Material and Methods: 60 inguinal hernia with age more than 18 years were taken and were divided in two groups; 30 patient group who underwent TAPP and 30 patient group who underwent TEPP. In 15 patients in both groups tackers were used and in other half fibrin glue was used for fixation of mesh using a 3mm catheter (Duplotip: Baxter Healthcare, which fits the Tisseel syringe. Results: The use of fibrin sealent has a distinct advantage in laparoscopic treatment of inguinal hernias compared with use of tackers as a method of mesh fixation. The use of fibrin sealant reduces the risk of post- and intraoperative complications, such as bleeding, seroma, chronic pain, has a lower incidence of postoperative neuralgia and provides an early faster return to social life. The recurrence rates do not vary much, but the operative time is slightly longer if the preparation time of the fibrin sealant is taken into consideration. In our study, we found a marginal difference in the cost of the two groups, fibrin sealant and stapled tackers. [Cukurova Med J 2015; 40(3.000: 457-465

  13. Acute fibrinous and organising pneumonia.

    Science.gov (United States)

    Gonçalves, João Rocha; Marques, Ricardo; Serra, Paula; Cardoso, Leila

    2017-09-07

    Acute fibrinous and organising pneumonia (AFOP) is a rare histological pattern of interstitial lung disease. The authors describe a 60-year-old woman admitted to the hospital for sustained fever, presenting with an alveolar opacity on chest X-ray, with the presumed diagnosis of community-acquired pneumonia and the onset of antibiotics. Since serological results suggested that Legionella pneumophila was the infectious agent, she was discharged on levofloxacin. A week later, she was again admitted with fever. CT scan showed opacities with crescentic morphology and a central ground-glass area suggestive of cryptogenic organising pneumonia. Microbiological, serological and autoimmunity tests were negative. She underwent surgical lung biopsy that revealed inflammatory infiltrate, macrophage desquamation, fibroblasts proliferation and fibrin deposition in the alveolar spaces, consistent with AFOP. She started corticotherapy with good response. Disease relapsed after prednisolone discontinuation, 10 months later. Currently, the patient is on prednisolone 5 mg/day without clinical and radiological recurrence. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Excess Fibrin Deposits Decrease Fetal Weight of Pregnant Mice Infected by Plasmodium berghei

    Directory of Open Access Journals (Sweden)

    Desy Andari

    2014-05-01

    Full Text Available Low birth weight is commonly attributed to malaria in pregnancy, but the cellular and molecular mechanisms that underlie this poor birth outcome are incompletely understood. A universally described histopathological feature of placental malaria is excessive deposition of fibrin, the end-product of the coagulation cascade. This study was conducted to compare fibrin deposit in pregnant mice that infected by Plasmodium berghei (treatment group to the normal pregnant mice (control group and its association with fetal weight. This research is in vivo experimental laboratory study that used 18 pregnant Balb/c mice which divided to the control the group (8 mice and treatment group (9 mice infected by P.berghei. Placentas were staining with Haematoxylin-Eosin (HE for fibrin deposits examination whereas fetal weight was performed with Mettler analytical balance AE 50. Fetal weight of the treatment group was lower than those of the control group (t test, p=0,002. Fibrin deposits were increased in the treatment group (t test, p=0,005 and influenced weight of fetuses (Spearman r= -0,586, p= 0,014. Weights of fetuses are interfered by fibrin deposits during malaria infection.

  15. Plasminogen fragments K 1-3 and K 5 bind to different sites in fibrin fragment DD.

    Science.gov (United States)

    Grinenko, T V; Kapustianenko, L G; Yatsenko, T A; Yusova, O I; Rybachuk, V N

    2016-01-01

    Specific plasminogen-binding sites of fibrin molecule are located in Аα148-160 regions of C-terminal domains. Plasminogen interaction with these sites initiates the activation process of proenzyme and subsequent fibrin lysis. In this study we investigated the binding of plasminogen fragments K 1-3 and K 5 with fibrin fragment DD and their effect on Glu-plasminogen interaction with DD. It was shown that the level of Glu-plasminogen binding to fibrin fragment DD is decreased by 50-60% in the presence of K 1-3 and K 5. Fragments K 1-3 and K 5 have high affinity to fibrin fragment DD (Kd is 0.02 for K 1-3 and 0.054 μМ for K 5). K 5 interaction is independent and K 1-3 is partly dependent on C-terminal lysine residues. K 1-3 interacts with complex of fragment DD-immobilized K 5 as well as K 5 with complex of fragment DD-immobilized K 1-3. The plasminogen fragments do not displace each other from binding sites located in fibrin fragment DD, but can compete for the interaction. The results indicate that fibrin fragment DD contains different binding sites for plasminogen kringle fragments K 1-3 and K 5, which can be located close to each other. The role of amino acid residues of fibrin molecule Аα148-160 region in interaction with fragments K 1-3 and K 5 is discussed.

  16. Fibrin nanostructures for biomedical applications

    Czech Academy of Sciences Publication Activity Database

    Riedelová-Reicheltová, Zuzana; Brynda, Eduard; Riedel, Tomáš

    2016-01-01

    Roč. 65, Suppl. 2 (2016), S263-S272 ISSN 0862-8408 R&D Projects: GA MŠk(CZ) LQ1604 Institutional support: RVO:61389013 Keywords : fibrinogen * fibrin-bound thrombin * nanostructures Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 1.461, year: 2016 http://www.biomed.cas.cz/physiolres/pdf/65%20Suppl%202/65_S263.pdf

  17. Developing Mesoscale Model of Fibrin-Platelet Network Representing Blood Clotting =

    Science.gov (United States)

    Sun, Yueyi; Nikolov, Svetoslav; Bowie, Sam; Alexeev, Alexander; Lam, Wilbur; Myers, David

    Blood clotting disorders which prevent the body's natural ability to achieve hemostasis can lead to a variety of life threatening conditions such as, excessive bleeding, stroke, or heart attack. Treatment of these disorders is highly dependent on understanding the underlying physics behind the clotting process. Since clotting is a highly complex multi scale mechanism developing a fully atomistic model is currently not possible. We develop a mesoscale model based on dissipative particle dynamics (DPD) to gain fundamental understanding of the underlying principles controlling the clotting process. In our study, we examine experimental data on clot contraction using stacks of confocal microscopy images to estimate the crosslink density in the fibrin networks and platelet location. Using this data we reconstruct the platelet rich fibrin network and study how platelet-fibrin interactions affect clotting. Furthermore, we probe how different system parameters affect clot contraction. ANSF CAREER Award DMR-1255288.

  18. Fibrin and poly(lactic-co-glycolic acid) hybrid scaffold promotes early chondrogenesis of articular chondrocytes: an in vitro study.

    Science.gov (United States)

    Sha'ban, Munirah; Kim, Soon Hee; Idrus, Ruszymah Bh; Khang, Gilson

    2008-04-25

    Synthetic- and naturally derived- biodegradable polymers have been widely used to construct scaffolds for cartilage tissue engineering. Poly(lactic-co-glycolic acid) (PLGA) are bioresorbable and biocompatible, rendering them as a promising tool for clinical application. To minimize cells lost during the seeding procedure, we used the natural polymer fibrin to immobilize cells and to provide homogenous cells distribution in PLGA scaffolds. We evaluated in vitro chondrogenesis of rabbit articular chondrocytes in PLGA scaffolds using fibrin as cell transplantation matrix. PLGA scaffolds were soaked in chondrocytes-fibrin suspension (1 x 10(6) cells/scaffold) and polymerized by dropping thrombin-calcium chloride (CaCl2) solution. PLGA-seeded chondrocytes was used as control. All constructs were cultured for a maximum of 21 days. Cell proliferation activity was measured at 1, 3, 7, 14 and 21 days in vitro using 3-(4,5-dimethylthiazole-2-yl)-2-, 5-diphenyltetrazolium-bromide (MTT) assay. Morphological observation, histology, immunohistochemistry (IHC), gene expression and sulphated-glycosaminoglycan (sGAG) analyses were performed at each time point of 1, 2 and 3 weeks to elucidate in vitro cartilage development and deposition of cartilage-specific extracellular matrix (ECM). Cell proliferation activity was gradually increased from day-1 until day-14 and declined by day-21. A significant cartilaginous tissue formation was detected as early as 2-week in fibrin/PLGA hybrid construct as confirmed by the presence of cartilage-isolated cells and lacunae embedded within basophilic ECM. Cartilage formation was remarkably evidenced after 3 weeks. Presence of cartilage-specific proteoglycan and glycosaminoglycan (GAG) in fibrin/PLGA hybrid constructs were confirmed by positive Safranin O and Alcian Blue staining. Collagen type II exhibited intense immunopositivity at the pericellular matrix. Chondrogenic properties were further demonstrated by the expression of genes encoded for

  19. Acute fibrinous and organising pneumonia: a case report and review of the literature.

    Science.gov (United States)

    Tzouvelekis, Argyris; Koutsopoulos, Anastasios; Oikonomou, Anastasia; Froudarakis, Marios; Zarogoulidis, Pavlos; Steiropoulos, Paschalis; Mikroulis, Dimitrios; Antoniades, Antonis; Bouros, Demosthenes

    2009-10-12

    Organising pneumonia is a distinct histopathological entity characterized by intra-alveolar buds of granulation tissue, called Masson bodies, which mainly comprise of activated fibroblasts and loose connective tissue. This histopathologic pattern has been described in idiopathic cases, characterizing cryptogenic organising pneumonia as well as in the context of pulmonary infection, drug-induced pneumonitis and following lung transplantation. Although distinct as a clinical and pathological entity, community organising pneumonia may present with atypical clinical and pathological features, such as intra-alveolar fillings of fibrin balls and organising tissue that resembles acute respiratory distress syndrome or diffuse alveolar damage. The latter characteristics constitute a recently described anatomoclinical entity called acute fibrinous and organising pneumonia. Here, we describe a rare case of acute fibrinous and organising pneumonia, in an otherwise healthy 65-year-old Greek woman who complained of dry cough, fever, weight loss and progressive dyspnoea. She had never been a smoker. Her clinical symptoms showed a rapid deterioration in the two weeks before admission, despite a course of oral antibiotics. After excluding infection and malignancy with routine laboratory tests and flexible bronchoscopy, high resolution computed tomography and video assisted thoracoscopic lung biopsy were performed. Diagnosis was based on radiological features typical of community organising pneumonia coupled with pathologic features characteristic of acute fibrinous and organising pneumonia. The patient was treated with corticosteroids and showed excellent clinical and radiological response three months after treatment initiation. Acute fibrinous and organising pneumonia is an extremely rare pathologic entity, often misdiagnosed as typical community organising pneumonia. To our knowledge, this is the seventh case of acute fibrinous and organising pneumonia in the literature, with no

  20. Effects of the incorporation of ε-aminocaproic acid/chitosan particles to fibrin on cementoblast differentiation and cementum regeneration.

    Science.gov (United States)

    Park, Chan Ho; Oh, Joung-Hwan; Jung, Hong-Moon; Choi, Yoonnyoung; Rahman, Saeed Ur; Kim, Sungtae; Kim, Tae-Il; Shin, Hong-In; Lee, Yun-Sil; Yu, Frank H; Baek, Jeong-Hwa; Ryoo, Hyun-Mo; Woo, Kyung Mi

    2017-10-01

    Cementum formation on the exposed tooth-root surface is a critical process in periodontal regeneration. Although various therapeutic approaches have been developed, regeneration of integrated and functional periodontal complexes is still wanting. Here, we found that the OCCM30 cementoblasts cultured on fibrin matrix express substantial levels of matrix proteinases, leading to the degradation of fibrin and the apoptosis of OCCM30 cells, which was reversed upon treatment with a proteinase inhibitor, ε-aminocaproic acid (ACA). Based on these findings, ACA-releasing chitosan particles (ACP) were fabricated and ACP-incorporated fibrin (fibrin-ACP) promoted the differentiation of cementoblasts in vitro, as confirmed by bio-mineralization and expressions of molecules associated with mineralization. In a periodontal defect model of beagle dogs, fibrin-ACP resulted in substantial cementum formation on the exposed root dentin in vivo, compared to fibrin-only and enamel matrix derivative (EMD) which is used clinically for periodontal regeneration. Remarkably, the fibrin-ACP developed structural integrations of the cementum-periodontal ligament-bone complex by the Sharpey's fiber insertion. In addition, fibrin-ACP promoted alveolar bone regeneration through increased bone volume of tooth roof-of-furcation defects and root coverage. Therefore, fibrin-ACP can promote cementogenesis and osteogenesis by controlling biodegradability of fibrin, implicating the feasibility of its therapeutic use to improve periodontal regeneration. Cementum, the mineralized layer on root dentin surfaces, functions to anchor fibrous connective tissues on tooth-root surfaces with the collagenous Sharpey's fibers integration, of which are essential for periodontal functioning restoration in the complex. Through the cementum-responsible fiber insertions on tooth-root surfaces, PDLs transmit various mechanical responses to periodontal complexes against masticatory/occlusal stimulations to support teeth

  1. Measurement of dynamic wedge angles and beam profiles by means of MRI ferrous sulphate gel dosimetry

    Science.gov (United States)

    Bengtsson, Magnus; Furre, Torbjørn; Rødal, Jan; Skretting, Arne; Olsen, Dag R.

    1996-02-01

    The purpose of this study is to examine the possible value of measuring the dose distribution in dynamic wedge photon beams using ferrous sulphate gel phantoms analysed by MRI. The wedge angles and dose profiles were measured for a field size of and for dynamic wedge angles of , , and using a 15 MV photon beam generated from a Clinac 2100 CD (Varian). The dose profiles obtained from MRI ferrous sulphate gel were in good agreement with the dose measurements performed with a diode detector array. Also, the wedge angles determined from the MRI ferrous sulphate gel agreed well with the values obtained by using film dosimetry and with calculations by use of TMS (treatment planning system) (Helax, Uppsala, Sweden). The study demonstrated that MRI ferrous sulphate gel dosimetry is an adequate tool for measurements of some beam characteristics of dynamic radiation fields.

  2. Determination of fibrin glue with antibiotics on collagen production in colon anastomosis

    Directory of Open Access Journals (Sweden)

    Stanojković Zoran

    2008-01-01

    Full Text Available Background/Aim. Fibrin glue is used as a matrix for local application of antibiotics. The aim of this study was to determine whether application of fibrin glue in combination with antibiotics can strengthen collagen production, prevent dehiscence of colon anastomoses due to infection, and reduce frequency of mortality and morbidity comparing to the control group and the group with fibrin glue application. Methods. The adult male Wistar rats divided into three groups were used in the experiment. The group 1 was the control one (after partial colon resection, colonic anastomoses performed were not treated, while to the group 2 and the group 3 were applied fibrin glue and fibrin glue with antibiotics (clindamycin and ceftriaxon on the site of anastomoses, respectively. Quality of colonic anastomoses were estimated by means of determination of collagen (L-hydroxyproline amount in the collon wall with anastomoses and histological analysis of this colon segment using light and electronic microscope on the days 5, 7 and 13 postoperatively. Results. The highest morbidity rate was registered in the group 1 (30%, then in the group 2 (13.3% and the lowest one in the group 3 (3.33%; p < 0,05 vs group 1. Mortality rate was significantly higher in the group 1 than in the group 3 (20% and 0%, respectively; p < 0,05. In the postoperative course, the highest concentrations of collagen in the colon wall on the site of anastomoses, which was confirmed by both light and electronic microscopy, were found in the group 3. Conclusion. The application of fibrin glue with antibiotics on colon anastomoses reduces the number of dehiscence, provides good mechanical protection and shorten the time of anastomoses healing.

  3. In vivo chicken model for peripheral intravascular human fibrin clot detection

    International Nuclear Information System (INIS)

    Hui, K.Y.

    1988-01-01

    A chicken model was prepared that provides a simple and economical method of evaluating the use of fibrin-specific monoclonal antibody 64C5 in the detection of peripheral vascular thrombi. Human fibrin was clotted in segments of a chicken's femoral artery and vein prior to intravenous injection of radioiodinated antibody 64C5. After a 3-hr perfusion time, the thrombosed and contralateral control segments of the vessels were excised and counted for radioactivity. The radiolabeled 64C5 uptake ratio of the thrombosed segment to the control segment was 5.4 +/- 1.2 (p less than 0.007) in the femoral artery, and 3.8 +/- 1.1 (p less than 0.02) in the femoral vein. This in vivo chicken model may also find application in studies of targeting agents for human fibrin

  4. Blood cell attachment to root surfaces treated with EDTA gel Adesão de células sangüíneas a superfícies radiculares tratadas com gel de EDTA

    Directory of Open Access Journals (Sweden)

    Fábio Renato Manzolli Leite

    2005-06-01

    Full Text Available Root debridement generates a smear layer which contains microorganisms and toxins that could interfere in periodontal healing. For this reason, different substances have been used to remove it and to expose collagen fibers at the tooth surface. Blood element adhesion to demineralized roots and clot stabilization by collagen fibers are extremely important for the success of periodontal surgery. The aim of this study was to evaluate the different patterns of blood element adsorption and adhesion to root surfaces only irrigated with distilled water and after application of a manipulated or an industrialized EDTA gel. Thirty samples were planed, equally divided into three groups and treated with distilled water (control, a manipulated EDTA gel or an industrialized one. Immediately after, samples were exposed to fresh blood and prepared for scanning electron microscopy. Untreated planed dentin presented the best results with blood cells entrapped in a thick web of fibrin. In the manipulated EDTA group, the web of fibrin was thick with sparse blood elements. The worst result was seen with the industrialized EDTA group, in which no blood elements could be seen. Statistical difference was obtained between control and industrialized EDTA groups. Surfaces only irrigated presented the most organized fibrin network and cell entrapment.A raspagem gera "smear layer", a qual contém microrganismos e toxinas que podem interferir no reparo periodontal. Por esse motivo, diferentes substâncias têm sido empregadas para remover esta camada e expor fibras colágenas da superfície dental. A adesão de elementos sangüíneos a superfícies radiculares desmineralizadas e a estabilização do colágeno pelas fibras colágenas são de extrema importância no sucesso da cirurgia periodontal. O objetivo deste estudo foi avaliar os diferentes padrões de adsorção e adesão de elementos sangüíneos a superfícies radiculares apenas irrigadas com água destilada e ap

  5. Sealing of Gastrointestinal Anastomoses with a Fibrin Glue-Coated Collagen Patch: A Safety Study

    DEFF Research Database (Denmark)

    Nordentoft, Tyge; Rømer, John; Sørensen, Michael

    2007-01-01

    gastrointestinal anastomoses with a collagen patch coated with fibrin glue. The study is a prospective, experimental animal study comparing sealed and unsealed gastrointestinal anastomoses. Laparotomy was performed in 11 pigs under general anesthesia. In each pig two anastomoses were performed on the small......Sealing of anastomoses has previously been tested with several methods, including sealing with liquid fibrin glue. Sealing with a collagen patch coated with fibrin glue components has never been systematically examined. The aim of the present study was to determine the safety of sealing...... intestine. One of the anastomoses was sealed with a collagen patch coated with fibrin glue components (TachoSil). The other anastomosis contained no sealing. The pigs were observed for 1 to 6 weeks. The observation period was followed by in vivo examination under general anesthesia and included observation...

  6. Role of pH Changes on Transforming Growth Factor-β1 Release and on the Fibrin Architecture of Platelet-rich Fibrin When Layered with Biodentine, Glass Ionomer Cement, and Intermediate Restorative Material.

    Science.gov (United States)

    Mullaguri, Harish; Suresh, Nandini; Surendran, Smitha; Velmurugan, Natanasabapathy; Chitra, Selvarajan

    2016-05-01

    The purpose of this study was to evaluate the influence of pH that is due to setting reaction of Biodentine, glass ionomer cement (GIC), and intermediate restorative material (IRM) on transforming growth factor-β1 (TGF-β1) release and on the fibrin architecture of platelet-rich fibrin (PRF). PRF was obtained from 8 volunteers and layered over the freshly prepared GIC, IRM, and Biodentine mixtures. TGF-β1 release was estimated by using enzyme-linked immunosorbent assay (ELISA), and fibrin structure of PRF was analyzed by using scanning electron microscope at 1 and 5 hours. Biodentine, GIC, and IRM increased the TGF-β1 release in comparison with that of control group (PRF alone) at both 1 and 5 hours. Biodentine released significantly more TGF-β1 than GIC and IRM at 1 hour. At 5 hours both GIC and Biodentine released significantly more TGF-β1 than IRM. The fibrin architecture of the Biodentine group was similar to that of control group at both 1 and 5 hours. In GIC and IRM groups the fibrillar structure of fibrin was collapsed, ill-defined, and cloudy with very thick fibers and irregularly reduced porosities. Biodentine induces larger amount of TGF-β1 release and also maintains the integrity of fibrin structure when compared with GIC and IRM when layered over PRF. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. [Eosinophilic pleural effusion possibly induced by fibrin sealant].

    Science.gov (United States)

    Kambayashi, Takatoyo; Suzuki, Takashi

    2012-02-01

    A 74-year-old man underwent right upper lobectomy for the lung cancer and bullectomy of right lower lobe. Fibrin sealant was used for sealing the excision line. The increase of the pleural effusion with increasing C-reactive protein( CRP) and eosinophilia was noted at the 17th day after the operation. The pleural effusion was transparent and yellowish colored suggesting transudatory liquid. The eosinophil in the pleural effusion was as high as 14%. The drainage of the pleural effusion was performed for 2 days resulting in disappearing the abnormal accumulation without any additional treatment. The cause of pleural effusion was supposed to be fibrin sealant by a positive result of the drug lymphocyte stimulation test.

  8. Nonuniform Internal Structure of Fibrin Fibers: Protein Density and Bond Density Strongly Decrease with Increasing Diameter

    Directory of Open Access Journals (Sweden)

    Wei Li

    2017-01-01

    Full Text Available The major structural component of a blood clot is a meshwork of fibrin fibers. It has long been thought that the internal structure of fibrin fibers is homogeneous; that is, the protein density and the bond density between protofibrils are uniform and do not depend on fiber diameter. We performed experiments to investigate the internal structure of fibrin fibers. We formed fibrin fibers with fluorescently labeled fibrinogen and determined the light intensity of a fiber, I, as a function of fiber diameter, D. The intensity and, thus, the total number of fibrin molecules in a cross-section scaled as D1.4. This means that the protein density (fibrin per cross-sectional area, ρp, is not homogeneous but instead strongly decreases with fiber diameter as D-0.6. Thinner fibers are denser than thicker fibers. We also determined Young’s modulus, Y, as a function of fiber diameter. Y decreased strongly with increasing D; Y scaled as D-1.5. This implies that the bond density, ρb, also scales as D-1.5. Thinner fibers are stiffer than thicker fibers. Our data suggest that fibrin fibers have a dense, well-connected core and a sparse, loosely connected periphery. In contrast, electrospun fibrinogen fibers, used as a control, have a homogeneous cross-section.

  9. Platelet-rich fibrin in the treatment of periodontal bone defects.

    Science.gov (United States)

    Ranganathan, Aravindhan T; Chandran, Chitraa R

    2014-05-01

    Periodontitis is characterized by the formation of true pockets, bone loss and attachment loss. Various techniques have been attempted in the past to truly regenerate the lost periodontal structures, albeit with variable outcome. In this evolution, the technique being tried out widely is the use of platelet rich concentrates, namely platelet-rich fibrin (PRF). In this report, we present a case of surgical treatment of osseous bone defects namely two walled crater and dehiscence treated in posterior teeth with autologously prepared platelet rich fibrin mixed with hydroxy apatite bone graft and PRF in the form of a membrane. Our results showed clinical improvements in all the clinical parameters postoperatively namely the pocket depth reduction and gain in attachment level and hence, PRF can be used alone or in combination with the bone graft to yield successful clinical results in treating periodontal osseous defects. Platelet-rich fibrin is an effective alternative to platelet-rich plasma (PRP) in reconstructing bone defects.

  10. 3D MR gel dosimetry with lung equivalent gel

    International Nuclear Information System (INIS)

    Scherer, J.; Solleder, M.; Schiessl, I.; Bogner, L.; Herbst, M.

    1998-01-01

    The MR gel dosimetry is used to verify complex 3D treatment plans. Till now this method served only for dose evaluation in homogeneous phantoms. On the way to build a heterogeneous anthropomorphic gel phantom, a lung equivalent gel with the density 0.4 g/cm 3 was developed. First experiments show a 1.55 times higher dose reponse in the low density gel (LD gel). The comparison of a dose distribution in a gel/LD gel/gel slab phantom with Monte Carlo calculations shows good agreement within 5%. More over the accuray of the measuring device magnetic resonance imager was studied in respect to the now exclusive digital image processing with the software MRD (MR dosimetry). Because of the dimensions of the Fricke gel phantom an artefact correction, based on the data from the unirradiated phantom proved to be essential. (orig.) [de

  11. Lesion measurement in non-radioactive DNA by quantitative gel electrophoresis

    International Nuclear Information System (INIS)

    Sutherland, J.C.; Chen, Chun Zhang; Emrick, A.; Hacham, H; Monteleone, D.; Ribeiro, E.; Trunk, J.; Sutherland, B.M.

    1989-01-01

    The gel electrophoresis method developed during the past ten years in our laboratories makes possible the quantitation of UV induced pyrimidine dimers, gamma ray induced single- and double-strand breaks and many other types of lesions in nanogram quantities of DNA. The DNA does not have to be labeled with radionuclides or of a particular conformation, thus facilitating the use of the method in measuring damage levels and repair rates in the DNA of intact organisms -- including man. The gel method can quantitate any lesion in DNA that either is, or can be converted to a single- or double-strand break. The formation of a strand break produces two shorter DNA molecules for each molecule that existed before the treatment that produced the break. Determining the number of breaks, and hence the number of lesions, becomes a matter of comparing the average lengths of molecules in samples differing only in lesion-induced breaks. This requires that we determine the distribution of mass of DNA on a gel as a function of its distance of migration and also the dispersion function of its distance of migration and also the dispersion function (the relationship between molecular length and distance of migration) in the gel electrophoresis system. 40 refs., 5 figs

  12. Narrow-band imaging can increase the visibility of fibrin caps after bleeding of esophageal varices: a case with extensive esophageal candidiasis.

    Science.gov (United States)

    Furuichi, Yoshihiro; Kasai, Yoshitaka; Takeuchi, Hirohito; Yoshimasu, Yuu; Kawai, Takashi; Sugimoto, Katsutoshi; Kobayashi, Yoshiyuki; Nakamura, Ikuo; Itoi, Takao

    2017-08-01

    A 58-year-old man with hepatitis B cirrhosis noticed black stools and underwent an endoscopy at a community hospital. The presence of esophageal varices (EVs) was confirmed, but the bleeding point was not found. He was referred to our institution and underwent a second endoscopy. Extensive white patches of esophageal candidiasis were visible on endoscopy by white-light imaging (WLI), but it was difficult to find the fibrin cap of the EVs. This was easier under narrow-band imaging (NBI), however, as the color turned red from absorption by hemoglobin adhered to it. We retrospectively measured the color differences (CD) between the fibrin cap and the surrounding mucosa 10 times using the CIE (L*a*b*) color space method. The median value of CD increased after NBI (13.9 → 43.0, p candidiasis, but the increased visibility of the fibrin cap by NBI enabled it to be found more easily. This is the first report of a case in which NBI was helpful in locating a fibrin cap of EVs.

  13. A comparative in vitro study of the viability of human keratinocytes grown on irradiated human amnion membrane and fibrin glue scaffolds

    International Nuclear Information System (INIS)

    Dorai, A.A.; Lim, C.K.; Azman, W.S.; Halim, A.S.

    2008-01-01

    Full text: The dried irradiated human amnion membrane has been used as a biological dressing for various clinical conditions. Being another biological membrane its potential as a scaffold to grow human keratinocytes is not known yet. To compare the growth patterns and cell viability of keratinocytes using fibrin glue and air dried amnion membrane as a scaffold. Keratinocytes were obtained from skin samples of six patients undergoing elective surgery. Fibrin glue (Tisseel, Baxter ) was diluted and used to coat the wells. Human dried amnion membrane was obtained and placed into the 24 well plates. Keratinocytes were seeded into the fibrin and amnion scaffold. Cell viability assay (MTT) was performed after 24, 48 and 72 hours. Finally the measurements were done by the Enzyme-Linked Immunosorbent Assay (ELISA) reader at 570 nm. Six patients consented for the study. The cells growing on the amnion scaffold showed a decreasing trend (20.67%, 17.94% and 16.78% respectively for 24, 48 and 72 hours). The cells growing on the fibrin scaffold showed a steady increase in number at 24, 48 and 72 hours (73.03%, 74.12% and 79.66%). The percentage of growth of normal human keratinocytes were significantly greater in the fibrin scaffold group (Mann - Whitney p = 0.002) for 24, 48 and 72 hours. The air dried irradiated human amnion membrane can be used as a scaffold to grow keratinocytes but however the growth pattern does not sustain with time. Fibrin glue supports the growth of human keratinocytes and shows an increasing pattern of growth with time. (Author)

  14. The initiation of embryonic-like collagen fibrillogenesis by adult human tendon fibroblasts when cultured under tension

    DEFF Research Database (Denmark)

    Bayer, Monika L; Yeung, Chin-Yan C; Kadler, Karl E

    2010-01-01

    to initiate collagen fibrillogenesis when cultured in fixed-length fibrin gels. Fibroblasts were dissected from semitendinosus and gracilis tendons from healthy humans and cultured in 3D linear fibrin gels. The fibroblasts synthesized an extracellular matrix of parallel collagen fibrils that were aligned...

  15. Human Kunitz-type protease inhibitor engineered for enhanced matrix retention extends longevity of fibrin biomaterials.

    Science.gov (United States)

    Briquez, Priscilla S; Lorentz, Kristen M; Larsson, Hans M; Frey, Peter; Hubbell, Jeffrey A

    2017-08-01

    Aprotinin is a broad-spectrum serine protease inhibitor used in the clinic as an anti-fibrinolytic agent in fibrin-based tissue sealants. However, upon re-exposure, some patients suffer from hypersensitivity immune reactions likely related to the bovine origin of aprotinin. Here, we aimed to develop a human-derived substitute to aprotinin. Based on sequence homology analyses, we identified the Kunitz-type protease inhibitor (KPI) domain of human amyloid-β A4 precursor protein as being a potential candidate. While KPI has a lower intrinsic anti-fibrinolytic activity than aprotinin, we reasoned that its efficacy is additionally limited by its fast release from fibrin material, just as aprotinin's is. Thus, we engineered KPI variants for controlled retention in fibrin biomaterials, using either covalent binding through incorporation of a substrate for the coagulation transglutaminase Factor XIIIa or through engineering of extracellular matrix protein super-affinity domains for sequestration into fibrin. We showed that both engineered KPI variants significantly slowed plasmin-mediated fibrinolysis in vitro, outperforming aprotinin. In vivo, our best engineered KPI variant (incorporating the transglutaminase substrate) extended fibrin matrix longevity by 50%, at a dose at which aprotinin did not show efficacy, thus qualifying it as a competitive substitute of aprotinin in fibrin sealants. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  16. Chin Symphysis Bone, Allograft, and Platelet-Rich Fibrin: Is the Combination Effective in Repair of Alveolar Cleft?

    Science.gov (United States)

    Movahedian Attar, Bijan; Naghdi, Navid; Etemadi Sh, Milad; Mehdizadeh, Mojdeh

    2017-05-01

    Secondary grafting of alveolar defects with iliac crest bone is a common treatment method in cleft patients. The aim of this study was to evaluate the effectiveness of the combination of symphysis bone, allograft, and platelet-rich fibrin in regeneration of alveolar defects compared with iliac bone graft. In this randomized clinical trial, patients with unilateral alveolar defects were divided randomly into two categories. Group A comprised patients in whom the combination of chin symphysis bone plus allogeneic bone material plus leukocyte- and platelet-rich fibrin was considered for treatment. Group B comprised patients in whom iliac bone graft was considered. Cone beam computed tomography before treatment and 1 year postoperatively was used for measurement of bone formation (bone volume in cubic centimeters). The data were analyzed by paired t and χ 2 tests via SPSS software (version 23; IBM, Armonk, NY). P platelet-rich fibrin is a proper combination for bone regeneration in alveolar defects with a small to moderate volume range. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Establishing the framework to support bioartificial heart fabrication using fibrin-based three-dimensional artificial heart muscle.

    Science.gov (United States)

    Hogan, Matthew; Mohamed, Mohamed; Tao, Ze-Wei; Gutierrez, Laura; Birla, Ravi

    2015-02-01

    Only 3000 heart transplants are performed in the USA every year, leaving some 30 000-70 000 Americans without proper care. Current treatment modalities for heart failure have saved many lives yet still do not correct the underlying problems of congestive heart failure. Tissue engineering represents a potential field of study wherein a combination of cells, scaffolds, and/or bioreactors can be utilized to create constructs to mimic, replace, and/or repair defective tissue. The focus of this study was to generate a bioartificial heart (BAH) model using artificial heart muscle (AHM), composed of fibrin gel and neonatal rat cardiac myocytes, and a decellularized scaffold, formed by subjecting an adult rat heart to a series of decellularization solutions. By suturing the AHM around the outside of the decellularized heart and culturing while suspended in media, we were able to retain functional cardiac cells on the scaffold as evinced by visible contractility. Observed contractility rate was correlated with biopotential measurements to confirm essential functionality of cardiac constructs. Cross-sections of the BAH show successful decellularization of the scaffold and contiguous cell-rich AHM around the perimeter of the heart. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  18. Fibrin and poly(lactic-co-glycolic acid hybrid scaffold promotes early chondrogenesis of articular chondrocytes: an in vitro study

    Directory of Open Access Journals (Sweden)

    Idrus Ruszymah BH

    2008-04-01

    Full Text Available Abstract Background Synthetic- and naturally derived- biodegradable polymers have been widely used to construct scaffolds for cartilage tissue engineering. Poly(lactic-co-glycolic acid (PLGA are bioresorbable and biocompatible, rendering them as a promising tool for clinical application. To minimize cells lost during the seeding procedure, we used the natural polymer fibrin to immobilize cells and to provide homogenous cells distribution in PLGA scaffolds. We evaluated in vitro chondrogenesis of rabbit articular chondrocytes in PLGA scaffolds using fibrin as cell transplantation matrix. Methods PLGA scaffolds were soaked in chondrocytes-fibrin suspension (1 × 106cells/scaffold and polymerized by dropping thrombin-calcium chloride (CaCl2 solution. PLGA-seeded chondrocytes was used as control. All constructs were cultured for a maximum of 21 days. Cell proliferation activity was measured at 1, 3, 7, 14 and 21 days in vitro using 3-(4,5-dimethylthiazole-2-yl-2-, 5-diphenyltetrazolium-bromide (MTT assay. Morphological observation, histology, immunohistochemistry (IHC, gene expression and sulphated-glycosaminoglycan (sGAG analyses were performed at each time point of 1, 2 and 3 weeks to elucidate in vitro cartilage development and deposition of cartilage-specific extracellular matrix (ECM. Results Cell proliferation activity was gradually increased from day-1 until day-14 and declined by day-21. A significant cartilaginous tissue formation was detected as early as 2-week in fibrin/PLGA hybrid construct as confirmed by the presence of cartilage-isolated cells and lacunae embedded within basophilic ECM. Cartilage formation was remarkably evidenced after 3 weeks. Presence of cartilage-specific proteoglycan and glycosaminoglycan (GAG in fibrin/PLGA hybrid constructs were confirmed by positive Safranin O and Alcian Blue staining. Collagen type II exhibited intense immunopositivity at the pericellular matrix. Chondrogenic properties were further

  19. Fibrinous pericarditis secondary to bacterial infection in a cat.

    Science.gov (United States)

    Tagawa, Michihito; Kurashima, Chihiro; Shimbo, Genya; Omura, Hiroshi; Koyama, Kenji; Horiuchi, Noriyuki; Kobayashi, Yoshiyasu; Kawamoto, Keiko; Miyahara, Kazuro

    2017-06-10

    A three-year-old spayed domestic short-haired cat presented for evaluation of weight loss, cardiomegaly and pleural effusion. Echocardiographic examination demonstrated a thickened pericardium with mild pericardial effusion and a large volume of pleural effusion characterized by exudate. Although the cat was treated with antibiotics, the clinical symptoms did not improve. The cat developed dyspnea and died on day 7. Necropsy revealed a large amount of modified transudates ascites, pleural effusion and markedly dilated pericardium. Histopathological examination revealed severe exudation of fibrin and granulation tissue in a thick layer of the epicardium. The cat was diagnosed with fibrinous pericarditis secondary to bacterial infection.

  20. Platelet-rich fibrin or platelet-rich plasma – which one is better? an opinion

    Directory of Open Access Journals (Sweden)

    Shweta Bansal

    2017-01-01

    Full Text Available The healing of hard and soft tissue in mediated by a wide range of intracellular and extracellular events that are regulated by signaling proteins. Platelets can play a crucial role in periodontal regeneration as they are the reservoirs of growth factors and cytokines which are the key factors for regeneration of bone and maturation of soft tissue. Platelet-rich plasma (PRP is first generation platelet concentrate. However, the short duration of cytokine release and its poor mechanical properties have resulted in search of new material. Platelet-rich fibrin (PRF is a natural fibrin-based biomaterial prepared from an anticoagulant-free blood harvest without any artificial biochemical modification (no bovine thrombin is required that allows obtaining fibrin membranes enriched with platelets and growth factors. The slow polymerization during centrifugation, fibrin-based structure, ease of preparation, minimal expense makes PRF somewhat superior in some aspect to PRP.

  1. Polymeric gel nanoparticle pH sensors for intracellular measurements

    OpenAIRE

    Almdal, Kristoffer; Andresen, Thomas Lars; Benjaminsen, Rikke Vicki; Christensen, Nynne Meyn; Henriksen, Jonas Rosager; Sun, Honghao

    2011-01-01

    Precise measurements of pH in cells and intracellular compartments are of importance to both the fundamental understanding of metabolism and to the development of drugs that are released from the endosomes-lysome pathway. We have developed polymer gel nanoparticles as carriers of covalently bound fluorophores for ratiometric measurements of pH. One pH insensitive fluorophore serves as a reference while one or more pH sensitive fluorophores serve to give the desired pH dependence of the output...

  2. Tunneled dialysis catheter exchange with fibrin sheath disruption is not associated with increased rate of bacteremia.

    Science.gov (United States)

    Valliant, Amanda M; Chaudhry, Muhammad K; Yevzlin, Alexander S; Astor, Brad; Chan, Micah R

    2015-01-01

    Tunneled dialysis catheters are the most common form of vascular access among incident dialysis patients in the United States. Fibrin sheath formation is a frequent cause of late catheter dysfunction requiring an exchange procedure with balloon disruption of the fibrin sheath. It is unknown whether fibrin sheath disruption is associated with increased incidence of bacteremia or catheter failure. We reviewed all tunneled dialysis catheter exchange procedures at the University of Wisconsin between January 2008 and December 2011. The primary outcome was incidence of bacteremia, defined as positive blood cultures within 2 weeks of the procedure. Catheter failure, requiring intervention or replacement, was examined as a secondary outcome. Baseline characteristics examined included diabetic status, gender, race and age. A total of 163 procedures were reviewed; 67 (41.1%) had fibrin sheath disruption and 96 did not. Bacteremia occurred in 4.5% (3/67) of those with and 3.1% (3/97) of those without fibrin sheath disruption (p=0.65). Fibrin sheath disruption was not significantly associated with the risk of catheter failure (adjusted hazard ratio [aHR]=1.34; 95% confidence interval [CI]: 0.87-2.10; p=0.18). Diabetes was associated with greater risk of catheter failure (aHR=1.88; 95% CI: 1.19-2.95; p=0.006), whereas higher age was associated with a lower risk of catheter failure (aHR per 10 years=0.83; 95% CI: 0.72-0.96; p=0.01). This study demonstrates that there is no significant increase in bacteremia and subsequent catheter dysfunction rates after fibrin sheath disruption compared to simple over the wire exchange. These results are encouraging given the large numbers of patients utilizing tunneled catheters for initial hemodialysis access and the known rates of fibrin sheath formation leading to catheter failure.

  3. Local and systemic effects of fibrin and cyanoacrylate adhesives on lung lesions in rabbits

    Directory of Open Access Journals (Sweden)

    Marcus V.H. Carvalho

    Full Text Available OBJECTIVES: Tissue adhesives can be used to prevent pulmonary air leaks, which frequently occur after lung interventions. The objective of this study is to evaluate local and systemic effects of fibrin and cyanoacrylate tissue adhesives on lung lesions in rabbits. METHODS: Eighteen rabbits were submitted to videothoracoscopy + lung incision alone (control or videothoracoscopy + lung incision + local application of fibrin or cyanoacrylate adhesive. Blood samples were collected and assessed for leukocyte, neutrophil and lymphocyte counts and interleukin-8 levels preoperatively and at 48 hours and 28 days post-operatively. After 28 days, the animals were euthanized for gross examination of the lung surface, and lung fragments were excised for histopathological analysis. RESULTS: Fibrin and cyanoacrylate produced similar adhesion scores of the lung to the parietal pleura. Microscopic analysis revealed uniform low-cellular tissue infiltration in the fibrin group and an intense tissue reaction characterized by dense inflammatory infiltration of granulocytes, giant cells and necrosis in the cyanoacrylate group. No changes were detected in the leukocyte, neutrophil or lymphocyte count at any time-point, while the interleukin-8 levels were increased in the fibrin and cyanoacrylate groups after 48 hours compared with the pre-operative control levels (p<0.01. CONCLUSION: Both adhesive agents promoted normal tissue healing, with a more pronounced local inflammatory reaction observed for cyanoacrylate. Among the serum markers of inflammation, only the interleukin-8 levels changed post-operatively, increasing after 48 hours and decreasing after 28 days to levels similar to those of the control group in both the fibrin and cyanoacrylate groups.

  4. Percutaneous treatment of femoral pseudoaneurysms: comparison of fibrin sealant against thrombin

    Directory of Open Access Journals (Sweden)

    Daniel Mendes Pinto

    2013-12-01

    Full Text Available INTRODUCTION: Femoral pseudoaneurysms are a complication that occurs in connection with up to 8% of percutaneous procedures. Of the available treatments, ultrasound guided thrombin injection has a high success rate and is well-tolerated by patients. The combination of thrombin and fibrinogen known as fibrin sealant forms a stable clot and can be used to treat pseudoaneurysms, particularly those with complex anatomy and larger size. OBJECTIVE: To compare the results of treating femoral pseudoaneurysm in two ways: Group T was treated with thrombin alone and Group T+F was treated with fibrin sealant (thrombin+fibrinogen. METHODS: A retrospective analysis was conducted of femoral pseudoaneurysm cases treated between January 2005 and December 2012. RESULTS: Twenty-eight patients were treated, 21 with thrombin alone and seven with fibrin sealant. All patients in group T were treated successfully, but only four patients in group T+F were treated successfully (57.1% success rate in Group T+F, p<0.01. The three cases of failure in group T+F needed surgery and in one of these cases the complication was embolization to the femoral bifurcation. The pseudoaneurysms that were treated with fibrin sealant were larger (25 cm3 in Group T and 57.7 cm3 in Group T+F, p=0.02 and required larger volumes of thrombin (0.5 mL in Group T and 1.0 mL in Group T+F, p<0.01. There was one complication in Group T and two complications in Group T+F (p<0.01. CONCLUSIONS: Irrespective of the small number of cases reviewed, treatment with thrombin alone was superior to treating with fibrin sealant, since it caused few complications and was more effective at correcting pseudoaneurysms.

  5. Rheological and DSC study of sol-gel transition in aqueous dispersions of industrially important polymers and colloids

    Energy Technology Data Exchange (ETDEWEB)

    Nishinari, K. [Osaka City Univ. (Japan). Dept. of Food and Nutrition

    1997-12-01

    Gelation kinetics, mechanical spectra, thermal scanning rheology (TSR), and differential scanning calorimetry (DSC) in aqueous solutions of gelling polymers and colloids such as seaweed polysaccharides (agarose, carrageenans), microbial polysaccharides (gellan, curdlan), plant polysaccharides (methylcellulose), globular proteins (casein, glycinin, {beta}-conglycinin), fibrous proteins (gelatin, fibrin), and polyvinyl alcohol, which are related to foods, cosmetics, biomedical and pharmaceutical applications, are described. Some gelation processes at a constant temperature have been treated successfully by an equation of first order kinetics or by other modified equations, and the molecular mechanism of gel formation is discussed briefly. For water-soluble polymers, the criterion of the gel or sol based on the frequency dependence of storage and loss moduli gives valuable informations. TSR and DSC are complementary, and the combination of these methods has been proved to be useful. (orig.) 81 refs.

  6. Measurement of Mechatronic Property of Biological Gel with Micro-Vibrating Electrode at Ultrasonic Frequency

    Directory of Open Access Journals (Sweden)

    Shigehiro Hashimoto

    2008-10-01

    Full Text Available A measurement system has been designed with a micro-vibrating electrode at ultrasonic frequency to measure local impedance of biological gel in vitro. The designed system consists of two electrodes, where one of the electrodes vibrates with a piezoelectric actuator. The component of variation at impedance between two electrodes with vibration of one electrode is analyzed at the corresponding spectrum. The manufactured system was applied to measure impedance of a physiological saline solution, a potassium chloride solution, a dextran aqueous solution, and an egg. The experimental results show that the designed system is effective to measure local mechatronic property of biological gel.

  7. Fibrin-genipin adhesive hydrogel for annulus fibrosus repair: performance evaluation with large animal organ culture, in situ biomechanics, and in vivo degradation tests

    Directory of Open Access Journals (Sweden)

    M Likhitpanichkul

    2014-07-01

    Full Text Available Annulus fibrosus (AF defects from annular tears, herniation, and discectomy procedures are associated with painful conditions and accelerated intervertebral disc (IVD degeneration. Currently, no effective treatments exist to repair AF damage, restore IVD biomechanics and promote tissue regeneration. An injectable fibrin-genipin adhesive hydrogel (Fib-Gen was evaluated for its performance repairing large AF defects in a bovine caudal IVD model using ex vivo organ culture and biomechanical testing of motion segments, and for its in vivo longevity and biocompatibility in a rat model by subcutaneous implantation. Fib-Gen sealed AF defects, prevented IVD height loss, and remained well-integrated with native AF tissue following approximately 14,000 cycles of compression in 6-day organ culture experiments. Fib-Gen repair also retained high viability of native AF cells near the repair site, reduced nitric oxide released to the media, and showed evidence of AF cell migration into the gel. Biomechanically, Fib-Gen fully restored compressive stiffness to intact levels validating organ culture findings. However, only partial restoration of tensile and torsional stiffness was obtained, suggesting opportunities to enhance this formulation. Subcutaneous implantation results, when compared with the literature, suggested Fib-Gen exhibited similar biocompatibility behaviour to fibrin alone but degraded much more slowly. We conclude that injectable Fib-Gen successfully sealed large AF defects, promoted functional restoration with improved motion segment biomechanics, and served as a biocompatible adhesive biomaterial that had greatly enhanced in vivo longevity compared to fibrin. Fib-Gen offers promise for AF repairs that may prevent painful conditions and accelerated degeneration of the IVD, and warrants further material development and evaluation.

  8. Reticuloendothelial hyperphagocytosis occurs in streptozotocin-diabetic rats. Studies with colloidal carbon, albumin microaggregates, and soluble fibrin monomers

    International Nuclear Information System (INIS)

    Cornell, R.P.

    1982-01-01

    In contrast to previous studies of diabetic humans and animals, which reported unchanged or depressed function, reticuloendothelial system (RES) hyperphagocytosis of colloidal carbon, 125 I-albumin microaggregates, and 125 I-fibrin monomers were observed in rats as early as 14 days after the induction of diabetes with streptozotocin (STZ). The fact that enhanced phagocytosis by RE macrophages was prevented by chronic insulin replacement therapy indicates that the diabetic internal environment of hyperglycemia and hypoinsulinemia was perhaps responsible for the observed changes. Experiments involving organ localization of intravenously administered particles, perfusion of isolated livers, and microscopic examination of the liver all suggested that increased Kupffer cell activity was the primary event in RES hyperphagocytosis by STZ-diabetic rats. Both hypertrophy and hyperplasia of Kupffer cells were apparent in livers of STZ-diabetic animals as evidenced by photomicrographs and hepatic cell quantification. Plasma fibronectin, which binds fibrin monomers to RE macrophages before phagocytosis, was significantly decreased in the circulation of STZ-diabetic rats, but the level of cell-associated fibronectin was not measured. Renal localization of urea-soluble 125 I-fibrin monomers exceeded splenic and pulmonary uptake in normal control rats and was enhanced in animals with STZ-diabetes. Changes in fibronectin levels, fibrin monomer localization, and Kupffer cell size and numbers in experimental diabetes in rats may have implications for the pathogenesis of vascular disease involving phagocytic mesangial and foam cells in diabetic humans

  9. Reticuloendothelial hyperphagocytosis occurs in streptozotocin-diabetic rats. Studies with colloidal carbon, albumin microaggregates, and soluble fibrin monomers.

    Science.gov (United States)

    Cornell, R P

    1982-02-01

    In contrast to previous studies of diabetic humans and animals, which reported unchanged or depressed function, reticuloendothelial system (RES) hyperphagocytosis of colloidal carbon, 125I-albumin microaggregates, and 125I-fibrin monomers were observed in rats as early as 14 days after the induction of diabetes with streptozotocin (STZ). The fact that enhanced phagocytosis by RE macrophages was prevented by chronic insulin replacement therapy indicates that the diabetic internal environment of hyperglycemia and hypoinsulinemia was perhaps responsible for the observed changes. Experiments involving organ localization of intravenously administered particles, perfusion of isolated livers, and microscopic examination of the liver all suggested that increased Kupffer cell activity was the primary event in RES hyperphagocytosis by STZ-diabetic rats. Both hypertrophy and hyperplasia of Kupffer cells were apparent in livers of STZ-diabetic animals as evidenced by photomicrographs and hepatic cell quantification. Plasma fibronectin, which binds fibrin monomers to RE macrophages before phagocytosis, was significantly decreased in the circulation of STZ-diabetic rats, but the level of cell-associated fibronectin was not measured. Renal localization of urea-soluble 125I-fibrin monomers exceeded splenic and pulmonary uptake in normal control rats and was enhanced in animals with STZ-diabetes. Changes in fibronectin levels, fibrin monomer localization, and Kupffer cell size and numbers in experimental diabetes in rats may have implications for the pathogenesis of vascular disease involving phagocytic mesangial and foam cells in diabetic humans.

  10. Fibrin Clots Are Equilibrium Polymers That Can Be Remodeled Without Proteolytic Digestion

    OpenAIRE

    Chernysh, Irina N.; Nagaswami, Chandrasekaran; Purohit, Prashant K.; Weisel, John W.

    2012-01-01

    Fibrin polymerization is a necessary part of hemostasis but clots can obstruct blood vessels and cause heart attacks and strokes. The polymerization reactions are specific and controlled, involving strong knob-into-hole interactions to convert soluble fibrinogen into insoluble fibrin. It has long been assumed that clots and thrombi are stable structures until proteolytic digestion. On the contrary, using the technique of fluorescence recovery after photobleaching, we demonstrate here that the...

  11. Radiation effects in polyolefins below the gel point as measured by torque rheometry

    International Nuclear Information System (INIS)

    Markovic, V.; Babic, D.; Silverman, J.

    1981-01-01

    Torque rheometry is used to obtain information about radiation effects on polymers (crosslinking, degradation) below the gel point. It is shown that rheometric melt viscosity measurements at different shear rates are related changes in the relaxation spectrum. In particular there is a significant radiation effect on low shear rate viscosities but a negligible effect on high shear rate viscosities. The fact that the shear rate in the torque rheometer oscillates about a mean value is utilized to relate torque amplitude measurements to entanglements at zero dose and to crosslink density at absorbed doses below or close to the gel point. (author)

  12. Effect of fibrin glue derived from snake venom on the viability of autogenous split-thickness skin graft

    Directory of Open Access Journals (Sweden)

    S.C. Rahal

    2004-01-01

    Full Text Available The aim of this study was to analyze the effect of snake venom derived from fibrin glue on the viability of split-thickness skin graft. Nine crossbreed dogs were used. Full-thickness skin segments measuring 4 x 4 cm were bilaterally excised from the proximal radial area on each dog. A split-thickness skin graft was harvestedfrom left lateral thoracic area using a freehand graft knife, and was secured to the left recipient bed using several simple interrupted sutures of 3-0 nylon (sutured graft. A split-thickness skin graft was harvested from the right lateral thoracic area using a graft knife. Fibrin glue derived from snake venom was applied to the recipient bed, and 8 equidistant simple interrupted sutures of 3-0 nylon were used to secure the skin graft (glued graft. Viable and nonviable areas were traced on a transparent sheet and measured using a Nikon Photomicroscope connected to a KS-300 image analysis system. The skin graft and recipient bed were collected from three dogs at day 7, 15, and 30 postoperative. The glued grafts had statistically higher graft viability than sutured grafts. Histological examination showed that the tissue repair process in the glued grafts was more accentuated than sutured grafts. It was possible to conclude that fibrin glue derived from snake venom increased survival of autogenous split-thickness skin graft.

  13. Optimization of vascularization-­inducing hydrogel bioinks for 3D bioprinting

    Energy Technology Data Exchange (ETDEWEB)

    Lui, E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Moya, Monica L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-09-12

    This study seeks to validate the reproducibility of previous bioprinting work at Lawrence Livermore National Laboratory (LLNL) on a new Aerotech motion controller system and to modify an existing bioink, fibrin, by adding varying percent volumes of hyaluronic acid (HA). Endothelial and fibroblast cells bioprinted in fibrin gels using the Aerotech system were confirmed to be more than 77 percent viable after one day, and all bioprinted samples retained sterility after one week of culture. To characterize cell behavior in fibrin with HA addition, static co-­culture gels with varying percent volumes of HA were cultured in vitro for one week. Resulting confocal microscope images showed increased cell network formation in all concentrations of HA compared to the control (no HA), and rheological tests mimicking static gel compositions displayed positive correlations between gelation time, gel stiffness (G’), and hyaluronic acid concentration. Although the current data is insufficient to quantitatively associate HA concentration with the level of cell vascularization, future work will aim to develop a targeted HA concentration in fibrin for maximum cell network formation, to optimize the printing process parameters for this new bioink composition, and to analyze cell viability in bioprinted fibrin-­HA structures.

  14. Incorporation of vitronectin into fibrin clots. Evidence for a binding interaction between vitronectin and gamma A/gamma' fibrinogen.

    Science.gov (United States)

    Podor, Thomas J; Campbell, Stephanie; Chindemi, Paul; Foulon, Denise M; Farrell, David H; Walton, Philip D; Weitz, Jeffrey I; Peterson, Cynthia B

    2002-03-01

    Vitronectin is an abundant plasma protein that regulates coagulation, fibrinolysis, complement activation, and cell adhesion. Recently, we demonstrated that plasma vitronectin inhibits fibrinolysis by mediating the interaction of type 1 plasminogen activator inhibitor with fibrin (Podor, T. J., Peterson, C. B., Lawrence, D. A., Stefansson, S., Shaughnessy, S. G., Foulon, D. M., Butcher, M., and Weitz, J. I. (2000) J. Biol. Chem. 275, 19788-19794). The current studies were undertaken to further examine the interactions between vitronectin and fibrin(ogen). Comparison of vitronectin levels in plasma with those in serum indicates that approximately 20% of plasma vitronectin is incorporated into the clot. When the time course of biotinylated-vitronectin incorporation into clots formed from (125)I-fibrinogen is monitored, vitronectin incorporation into the clot parallels that of fibrinogen in the absence or presence of activated factor XIII. Vitronectin binds specifically to fibrin matrices with an estimated K(d) of approximately 0.6 microm. Additional vitronectin subunits are assembled on fibrin-bound vitronectin multimers through self-association. Confocal microscopy of fibrin clots reveals the globular vitronectin aggregates anchored at intervals along the fibrin fibrils. This periodicity raised the possibility that vitronectin interacts with the gamma A/gamma' variant of fibrin(ogen) that represents about 10% of total fibrinogen. In support of this concept, the vitronectin which contaminates fibrinogen preparations co-purifies with the gamma A/gamma' fibrinogen fraction, and clots formed from gamma A/gamma' fibrinogen preferentially bind vitronectin. These studies reveal that vitronectin associates with fibrin during coagulation, and may thereby modulate hemostasis and inflammation.

  15. Sol gel based fiber optic sensor for blook pH measurement

    International Nuclear Information System (INIS)

    Grant, S. A.; Glass, R. S.

    1996-01-01

    This paper describes a fiber-optic pH sensor based upon sol-gel encapsulation of a self-referencing dye, seminaphthorhodamine-1 carboxylate (SNARF-1C). The simple sol-gel fabrication procedure and low coating leachability are ideal for encapsulation and immobilization of dye molecules onto the end of an optical fiber. A miniature bench-top fluorimeter system was developed for use with the optical fiber to obtain pH measurements. Linear and reproducible responses were obtained in human blood in the pH range 6.8 to 8.0, which encompasses the clinically-relevant range. Therefore, this sensor can be considered for in vivo use

  16. [Use of fibrin glue in the prevention of leakage in pancreatico-jejunal anastomoses].

    Science.gov (United States)

    Stojanović, M; Jeremic, M; Stojanović, P; Stojiljković, M; Gmijović, D; Stanojković, Z; Savić, V; Djordjević, V; Cvetković, Z; Kostov, M; Colović, R

    2002-01-01

    The aim of this study was to test the protective effects of fibrin sealing on the pancreatico-jejunostomy (PJA), the high-risk anastomosis following pancreas head resection. Experimental study was performed on the mongrel dogs, divided in two groups (20 animals each): Experimental group-with end to end "dunking" PJA, protected by temporary occlusion of the pancreatic duct with fibrin sealant/Tissucol/Immuno Ag/, while control group was without any protective procedure. The animals were followed 5 months in order to study: protective effects of such procedure on the PJA quantified with the percent of anastomotic leakage, effects of the exocrine secretion and effects the endocrine function Results: PJA leakage occurred in 13.33% in control group. No leakage was registered in experimental group. Biochemical, histological and electron microscopic study showed slight transitory elevation of amylase levels. Fibrin glue plug was dissolved and pancreatic juice output was reestablished 12th days postoperatively. Long term follow-up showed no damages of the endocrine and exocrine pancreas. Pancreatic duct occlusion with fibrin glue appeared to be an useful method in the prevention of pancreatico-jejunostomy leakage, without negative effects on the exocrine and endocrine pancreas.

  17. Use of fibrin sealants for the localized, controlled release of cefazolin

    Science.gov (United States)

    Tredwell, Stephen; Jackson, John K.; Hamilton, Donald; Lee, Vivian; Burt, Helen M.

    2006-01-01

    Background Fibrin sealants are used increasingly in surgery to reduce bleeding and improve wound healing. They have great potential as biocompatible, biodegradable drug delivery systems, because the sealant may adhere to the target tissue and allow controlled release of the drug over an extended period. We investigated the encapsulation, stability and controlled release of erythromycin and cefazolin from Beriplast fibrin sealants (Aventis Behring Canada). Methods Drug-loaded clots were cast in glass vials and allowed to set. We observed the clots for drug precipitation and aggregation, and we assessed the effect of drug encapsulation on clot strength. Drug stability and release from the clots in phosphate buffered saline (PBS) was quantified by ultraviolet and visible violet absorbance spectroscopy and high-performance liquid chromatography. Results Erythromycin was found to release slowly from the fibrin clots over the first 2 hours but then degrade rapidly. Cefazolin was found to be very stable in clots in PBS (97% stable at 2 d and 93% stable at 5 d). The drug released in a controlled manner over 2 days, with most being released during the first day. The dose of drug released could be varied by changing the amount placed in the thrombin solution. Clot thickness had no effect on the rate of cefazolin release. Conclusion Overall, the 2-day release profile and the excellent stability of the drug suggest that cefazolin-loaded fibrin sealants may offer an effective route of postoperative antibiotic delivery. PMID:17152573

  18. Fibrin Sheath Angioplasty: A Technique to Prevent Superior Vena Cava Stenosis Secondary to Dialysis Catheters

    Science.gov (United States)

    Hacker, Robert I.; Garcia, Lorena De Marco; Chawla, Ankur; Panetta, Thomas F.

    2012-01-01

    Fibrin sheaths are a heterogeneous matrix of cells and debris that form around catheters and are a known cause of central venous stenosis and catheter failure. A total of 50 cases of central venous catheter fibrin sheath angioplasty (FSA) after catheter removal or exchange are presented. A retrospective review of an outpatient office database identified 70 eligible patients over a 19-month period. After informed consent was obtained, the dialysis catheter exiting the skin was clamped, amputated, and a wire was inserted. The catheter was then removed and a 9-French sheath was inserted into the superior vena cava, a venogram was performed. If a fibrin sheath was present, angioplasty was performed using an 8 × 4 or 10 × 4 balloon along the entire length of the fibrin sheath. A completion venogram was performed to document obliteration of the sheath. During the study, 50 patients were diagnosed with a fibrin sheath, and 43 had no pre-existing central venous stenosis. After FSA, 39 of the 43 patient's (91%) central systems remained patent without the need for subsequent interventions; 3 patients (7%) developed subclavian stenoses requiring repeat angioplasty and stenting; 1 patent (2.3%) developed an occlusion requiring a reintervention. Seven patients with prior central stenosis required multiple angioplasties; five required stenting of their central lesions. Every patient had follow-up fistulograms to document long-term patency. We propose that FSA is a prudent and safe procedure that may help reduce the risk of central venous stenosis from fibrin sheaths due to central venous catheters. PMID:23997555

  19. Experimental closure of gunshot wounds by fibrin glue with antibiotics in pigs

    Directory of Open Access Journals (Sweden)

    Đenić Nebojša

    2015-01-01

    Full Text Available Background/Aim. Gunshot wounds caused by the automatic rifle M70AB2 (AK-47 7.62 mm, after the primary surgical management, were closed with delayed primary suture during the next four to seven days. This period coincides with the fibroblastic phase of wound healing. Fibrin glue is used as a local hemostatic and as a matrix for the local dosed release of antibiotics. Antibiotics addition to fibrin glue resulted in continuous diffusion into the surrounding next 4 to 7 days. The aim of this study was to create the preconditions for gunshot wounds closing without complications by the application of fibrin glue with antibiotics 24 h after primary surgical treatment. Methods. A total of 14 pigs were wounded in the gluteofemoral region by the bullet M67, initial velocity of 720 m/s. All wounded animals were surgically treated according to the principles of the warsurgery doctrine. Seven wounds were closed with primary delayed suture four days after the primary surgical treatment (traditional approach. Fibrin glue with antibiotics was introduced in seven wounds during the primary surgical treatment and primary delayed suture was done after 24 h. The macroscopic appearance and the clinical assessment of the wound were done during the primary surgical treatment and during its revision after 24 h, as well as histopathological findings at the days 4 and 7 after wounding. Results. Gunshot wounds caused by the automatic rifle M70AB2 (AK-47 7.62 mm, and treated with fibrin glue with antibiotics after primary surgical management, were closed with primary delayed suture after 24 h. In further wound evolution there were no complications. Conclusion. Uncomplicated soft-tissue wounds caused by an automatic M70AB2 rifle may be closed primarily with delayed suture without the risk of developing complications if on revision, 24 h after primary surgery, there were no present necrotic tissues, hematoma, and any signs of infection when fibrin glue with antibiotics

  20. Experimental closure of gunshot wounds by fibrin glue with antibiotics in pigs

    OpenAIRE

    Đenić Nebojša; Višnjić Milan; Dragović Saša; Bojanić Vladmila; Bojanić Zoran; Đurđević Dragan; Đinđić Boris; Kostov Miloš

    2015-01-01

    Background/Aim. Gunshot wounds caused by the automatic rifle M70AB2 (AK-47) 7.62 mm, after the primary surgical management, were closed with delayed primary suture during the next four to seven days. This period coincides with the fibroblastic phase of wound healing. Fibrin glue is used as a local hemostatic and as a matrix for the local dosed release of antibiotics. Antibiotics addition to fibrin glue resulted in continuous diffusion into the surrounding n...

  1. Clot friction variation with fibrin content; implications for resistance to thrombectomy.

    Science.gov (United States)

    Gunning, Gillian M; McArdle, Kevin; Mirza, Mahmood; Duffy, Sharon; Gilvarry, Michael; Brouwer, Patrick A

    2018-01-01

    Despite significant advancements in the procedural efficacy of mechanical thrombectomy in patients with ischemic stroke in recent years, there still remains a portion of the population that does not achieve good recanalization. The reasons for this may be varied. We hypothesized that static friction between the clot and the vessel, or catheter wall might contribute to the difficulty in removing the clot. To determine if there is a relationship between clot composition and the resistance to sliding (friction) which might contribute to resistance to clot removal. As clot composition can vary significantly, we investigated five different types of clot in order to measure their respective frictional properties. To do this, a custom-made testing apparatus was created, consisting of various replaceable low-friction surfaces on which the clots could be placed. The surface was then gradually tilted until the clots began to slide; the angle at which this occurred is related to the coefficient of friction of the clots. The experiment was repeated on a bovine aortic surface in order to confirm the results. We found that fibrin-rich clots (friction than clots with a red blood cell content >20%. This result was confirmed by repeating the experiment on a bovine aortic surface as a representation of the interaction between clots and the arterial wall. The friction properties of clots were found to be related to the content ratio of fibrin to red blood cells. Future imaging techniques that could show fibrin and red blood cell content might help us to predict the 'stickiness' of a clot. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. Wound healing and degradation of the fibrin sealant Beriplast P following partial liver resection in rabbits.

    Science.gov (United States)

    Kroez, Monika; Lang, Wiegand; Dickneite, Gerhard

    2005-01-01

    The objective of this study was to investigate the degradation kinetics of the fibrin sealant (FS) Beriplast P in an experimental liver surgery model in rabbits. A partial liver resection was performed in 21 rabbits, and the wound area covered with Beriplast P to ensure hemostasis. Wound healing of the resection sites was evaluated morphologically over 11 weeks. Degradation of the FS was evaluated by measuring the thickness of the remaining fibrin layer. Plasma samples were analyzed for antibodies against fibrinogen, albumin, thrombin, fibrin, and factor XIII. No postoperative hemorrhage was observed, indicating successful hemostasis throughout. The FS was degraded with a half-life of about 25 days postapplication and was completely replaced by granulation tissue within 9 weeks. The FS degradation and tissue development followed the general stages of wound healing: inflammation and resorption, proliferation, organization and production of collagen, maturation, and scarring. An immune reaction was elicited against the main four human proteins of the FS. The antibody titers peaked on day 14, with a gradual decrease thereafter. We conclude that the FS accomplished hemostasis, facilitated healing in accordance with natural processes, and was completely degraded over time. In humans, the reduced immunogenicity of the FS would potentially increase its degradation half-life.

  3. Lyophilized Platelet-Rich Fibrin (PRF Promotes Craniofacial Bone Regeneration through Runx2

    Directory of Open Access Journals (Sweden)

    Qi Li

    2014-05-01

    Full Text Available Freeze-drying is an effective means to control scaffold pore size and preserve its composition. The purpose of the present study was to determine the applicability of lyophilized Platelet-rich fibrin (LPRF as a scaffold for craniofacial tissue regeneration and to compare its biological effects with commonly used fresh Platelet-rich fibrin (PRF. LPRF caused a 4.8-fold ± 0.4-fold elevation in Runt-related transcription factor 2 (Runx2 expression in alveolar bone cells, compared to a 3.6-fold ± 0.2-fold increase when using fresh PRF, and a more than 10-fold rise of alkaline phosphatase levels and mineralization markers. LPRF-induced Runx2 expression only occurred in alveolar bone and not in periodontal or dental follicle cells. LPRF also caused a 1.6-fold increase in osteoblast proliferation (p < 0.001 when compared to fresh PRF. When applied in a rat craniofacial defect model for six weeks, LPRF resulted in 97% bony coverage of the defect, compared to 84% for fresh PRF, 64% for fibrin, and 16% without scaffold. Moreover, LPRF thickened the trabecular diameter by 25% when compared to fresh PRF and fibrin, and only LPRF and fresh PRF resulted in the formation of interconnected trabeculae across the defect. Together, these studies support the application of lyophilized PRF as a biomimetic scaffold for craniofacial bone regeneration and mineralized tissue engineering.

  4. Development of novel Sol-Gel Indicators (SGI's) for in-situ environmental measurements: Part 1, Program and a new pH Sol-Gel Indicator

    International Nuclear Information System (INIS)

    Livingston, R.R.; Baylor, L.; Wicks, G.G.

    1992-01-01

    The feasibility of incorporating analytical indicators into a sol-gel glassy matrix and then coating substrates with this composite material has bee demonstrated. Substrates coated include paper, wood, glass, and the lens of an analytical probe. The first SRTC sol-gel indicator, comprising bromophenol blue dispersed in a silica matrix, was fabricated and successfully used to measure solution pH in the range of pH 3.0 to 7.5. material exhibited a quick response time, as measured by color changes both qualitatively and quantitatively, and the measuring device was reversible or reusable. Additional indicators with responses over other ranges as well as indicators sensitive to the presence of elements of interest, are also under development. The new SGI composites possess promising properties and an excellent potential for performing a variety important in-situ environmental measurements and area discussed in this report

  5. The effect of fibrin sealant on bioactive glass S53P4 particles – pH impact and dissolution characteristics in vitro

    Directory of Open Access Journals (Sweden)

    Jussi Sarin

    2016-12-01

    Full Text Available Fibrin glue, a two-component tissue adhesive, has a range of clinical indications. Bioactive glass (BG S53P4 has been approved for clinical use in several craniomaxillofacial and orthopedic applications. Although sometimes used simultaneously, there is no data available regarding the possible interaction of these two biocompatible substances. In this in vitro study, using a BG particle concentration of 4 mg/ml, a 0.4 unit pH increment (p < 0.001 was observed in simulated body fluid (SBF after a 7-day incubation period. The addition of fibrin glue (0.13 g, SD 0.04; or 3.7 mg/ml on top of the BG particles raised further the pH by 0.5 units (p < 0.001. The difference between these groups was statistically significant (p = 0.008. With a BG concentration of 25 mg/ml and a fibrin glue concentration of 18 mg/ml during a 14-day incubation period, a pH increment of 0.6 units and SBF ion concentration change of Ca, K, Mg, Na, P and Si ions was seen. Moreover, a penetration depth between 4 and 6 mm was observed when fibrin glue was applied on top of a bed of BG particles. Conclusions: Fibrin glue is not likely to have a distracting effect on BG-induced pH increase of the SBF although it might delay early BG surface reactions based on ion concentration measurements. Fibrin glue penetrated to the interparticle space to some extent, binding the particles together for easy clinical use of BG.

  6. Efficacy of fibrin-sealants in reducing biliary leakage following laparoscopic common bile duct exploration.

    Science.gov (United States)

    Parra-Membrives, Pablo; Martínez-Baena, Darío; Lorente-Herce, José Manuel; Martín-Balbuena, Ramón

    2018-05-21

    In spite of the acquired experience with laparoscopic common bile duct exploration (LCBDE) for choledocholithiasis management, there is still a risk of biliary leakage of 5% to 15% following choledochotomy closure. We evaluate the usefulness of fibrin-collagen sealants to reduce the incidence of biliary fistula after laparoscopic choledochorrhaphy. We report a retrospective analysis of 96 patients undergoing LCBDE from March 2009 to March 2017, whose closure of the bile duct was completed by antegrade stenting and choledochorraphy or by performing a primary suture. The study population was divided into two groups according to whether they received a collagen-fibrin sealant covering the choledochorrhaphy or not, analyzing the incidence of postoperative biliary fistula in each group. Thirty-nine patients (41%) received a fibrin-collagen sponge while the bile duct closure was not covered in the remaining 57 patients (59%). The incidence of biliary fistula was 7.7% (3 patients) in the first group and 14% (8 patients) in the second group (P=.338). In patients who underwent primary choledochorraphy, the fibrin-collagen sealant reduced the incidence of biliary leakage significantly (4.5% vs. 33%, P=.020), which was a protective factor with an odds ratio of 10.5. Fibrin-collagen sealants may decrease the incidence of biliary fistula in patients who have undergone primary bile duct closure following LCBDE. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Autologous fibrin sealant (Vivostat®) in the neurosurgical practice: Part I: Intracranial surgical procedure

    Science.gov (United States)

    Graziano, Francesca; Certo, Francesco; Basile, Luigi; Maugeri, Rosario; Grasso, Giovanni; Meccio, Flavia; Ganau, Mario; Iacopino, Domenico G.

    2015-01-01

    Background: Hemorrhages, cerebrospinal fluid (CSF) fistula and infections are the most challenging postoperative complications in Neurosurgery. In this study, we report our preliminary results using a fully autologous fibrin sealant agent, the Vivostat® system, in achieving hemostasis and CSF leakage repair during cranio-cerebral procedures. Methods: From January 2012 to March 2014, 77 patients were studied prospectively and data were collected and analyzed. Autologous fibrin sealant, taken from patient's blood, was prepared with the Vivostat® system and applied on the resection bed or above the dura mater to achieve hemostasis and dural sealing. The surgical technique, time to bleeding control and associated complications were recorded. Results: A total of 79 neurosurgical procedures have been performed on 77 patients. In the majority of cases (98%) the same autologous fibrin glue provided rapid hemostasis and dural sealing. No patient developed allergic reactions or systemic complications in association with its application. There were no cases of cerebral hematoma, swelling, infection, or epileptic seizures after surgery whether in the immediate or in late period follow-up. Conclusions: In this preliminary study, the easy and direct application of autologous fibrin sealant agent helped in controlling cerebral bleeding and in providing prompt and efficient dural sealing with resolution of CSF leaks. Although the use of autologous fibrin glue seems to be safe, easy, and effective, further investigations are strongly recommended to quantify real advantages and potential limitations. PMID:25984391

  8. Diffusion MRI for rectal cancer staging: ADC measurements before and after ultrasonographic gel lumen distension

    Energy Technology Data Exchange (ETDEWEB)

    Palmucci, S., E-mail: spalmucci@sirm.org; Piccoli, M.; Piana, S.; Foti, P.V.; Siverino, R.O.A.; Mauro, L.A.; Milone, P.; Ettorre, G.C.

    2017-01-15

    Objectives: To compare Apparent Diffusion Coefficient (ADC) measurements in rectal neoplastic lesions before and after lumen distension obtained with sonography transmission gel. Methods: From January 2014 to July 2016, 25 patients (average age 63.7, range 41–85, 18 males) were studied for pre-treatment rectal cancer staging using a 1.5 T MRI. Diffusion MRI was obtained using echo-planar imaging with b = 800 value; all patients were studied acquiring diffusion sequences with and without rectal lumen distension obtained using sonography transmission gel. In both diffusion sequences, two blinded readers calculated border ADC values and small ADC values, drawing regions of interest respectively along tumour borders and far from tumour borders. Mean ADC values among readers − for each type of ADC measurement − were compared using Wilcoxon matched pairs signed rank test. Correlation was assessed using Pearson analysis. Results: Border ADC mean value for diffusion MR sequences without endorectal contrast was 1.122 mm{sup 2}/sec, with 95% Confidence Interval (CI) = 1.02–1.22; using gel lumen distension, higher border ADC mean value of 1.269 mm{sup 2}/s (95% CI = 1.16–1.38) was obtained. Wilcoxon matched pairs signed rank test revealed statistical difference (p < 0.01); a strong Pearson correlation was reported, with r value of 0.69. Small-ADC mean value was 1.038 mm{sup 2}/s (95% CI = 0.91–1.16) for diffusion sequences acquired without endorectal distension and 1.127 mm{sup 2}/s (95% CI = 0.98–1.27) for diffusion sequences obtained after endorectal gel lumen distension. Wilcoxon analysis did not show statistical difference (p = 0.13). A very strong positive correlation was observed, with r value of 0.81. Conclusions: ADC measurements are slightly higher using endorectal sonographic transmission gel; ROI should be traced far from tumour borders, to minimize gel filled-pixel along the interface between lumen and lesion. Further studies are needed to

  9. Diffusion MRI for rectal cancer staging: ADC measurements before and after ultrasonographic gel lumen distension

    International Nuclear Information System (INIS)

    Palmucci, S.; Piccoli, M.; Piana, S.; Foti, P.V.; Siverino, R.O.A.; Mauro, L.A.; Milone, P.; Ettorre, G.C.

    2017-01-01

    Objectives: To compare Apparent Diffusion Coefficient (ADC) measurements in rectal neoplastic lesions before and after lumen distension obtained with sonography transmission gel. Methods: From January 2014 to July 2016, 25 patients (average age 63.7, range 41–85, 18 males) were studied for pre-treatment rectal cancer staging using a 1.5 T MRI. Diffusion MRI was obtained using echo-planar imaging with b = 800 value; all patients were studied acquiring diffusion sequences with and without rectal lumen distension obtained using sonography transmission gel. In both diffusion sequences, two blinded readers calculated border ADC values and small ADC values, drawing regions of interest respectively along tumour borders and far from tumour borders. Mean ADC values among readers − for each type of ADC measurement − were compared using Wilcoxon matched pairs signed rank test. Correlation was assessed using Pearson analysis. Results: Border ADC mean value for diffusion MR sequences without endorectal contrast was 1.122 mm 2 /sec, with 95% Confidence Interval (CI) = 1.02–1.22; using gel lumen distension, higher border ADC mean value of 1.269 mm 2 /s (95% CI = 1.16–1.38) was obtained. Wilcoxon matched pairs signed rank test revealed statistical difference (p < 0.01); a strong Pearson correlation was reported, with r value of 0.69. Small-ADC mean value was 1.038 mm 2 /s (95% CI = 0.91–1.16) for diffusion sequences acquired without endorectal distension and 1.127 mm 2 /s (95% CI = 0.98–1.27) for diffusion sequences obtained after endorectal gel lumen distension. Wilcoxon analysis did not show statistical difference (p = 0.13). A very strong positive correlation was observed, with r value of 0.81. Conclusions: ADC measurements are slightly higher using endorectal sonographic transmission gel; ROI should be traced far from tumour borders, to minimize gel filled-pixel along the interface between lumen and lesion. Further studies are needed to investigate better

  10. Fibrin glue on an aortic cusp detected by transesophageal echocardiography after valve-sparing aortic valve replacement: a case report.

    Science.gov (United States)

    Nakahira, Junko; Ishii, Hisanari; Sawai, Toshiyuki; Minami, Toshiaki

    2015-03-07

    Fibrin glue is used commonly during cardiac surgery but can behave as an intracardiac abnormal foreign body following surgery. There have been few such cases reported, and they were typically noticed only because of the resulting catastrophic cardiac conditions, such as valvular malfunction. We report a case where, for the first time, transesophageal echocardiography was used to detected fibrin glue that was adherent to the ventricular side of a patient's aortic valve immediately after aortic declamping. A 45-year-old Japanese man with Marfan syndrome underwent an aortic valve-sparing operation to treat moderate aortic valve regurgitation resulting from enlargement of his right coronary cusp. Fibrin glue was lightly applied to the suture line between the previous and new grafts. Transesophageal echocardiography performed prior to weaning from the cardiopulmonary bypass revealed mild aortic valve regurgitation in addition to a mobile membranous structure attached to the ventricular side of his aortic valve. It was identified as fibrin glue. We resolved the regurgitation by removing the fibrin glue and repeating the aortic cusp plication. The patient had no complications during recovery. Fibrin glue can act as an intracardiac foreign body and lead to a potentially fatal embolism. We demonstrated the use of transesophageal echocardiography to detect a fibrin glue-derived intracardiac abnormal foreign body and to confirm its removal. To the best of our knowledge, this is the first case where fibrin glue adherent to the aortic valve was detected by transesophageal echocardiography. These findings demonstrate the importance of using transesophageal echocardiography during cardiac surgery that involves using biological glues.

  11. Soft tissue regeneration using leukocyte-platelet rich fibrin after exeresis of hyperplastic gingival lesions: two case reports.

    Science.gov (United States)

    di Lauro, A E; Abbate, D; Dell'Angelo, B; Iannaccone, G A; Scotto, F; Sammartino, G

    2015-11-02

    Leukocyte-platelet rich fibrin belongs to a second generation of platelet concentrates that does not need biochemical blood manipulation. It is used for tissue healing and regeneration in periodontal and oral-maxillofacial surgery. We report two cases of hyperplastic gingival lesions treated by exeresis and application of leukocyte-platelet rich fibrin membranes in order to improve and accelerate tissue healing. Two patients (a 78-year-old Caucasian woman and a 30-year-old Caucasian man) were treated for hyperplastic gingival lesions. They underwent to exeresis of lesions and application of leukocyte-platelet rich fibrin membranes. Tissue healing was clinically evaluated after 1, 3, 7, 14 and 30 postoperative days. No recurrences were observed after 2 years of semi-annual follow up. We obtained rapid and good healing of soft tissues probably due to the elevated content of leukocytes, platelets and growth factors in the leukocyte-platelet rich fibrin. Based on our results we suggest the use of leukocyte-platelet rich fibrin to cover wounds after exeresis of oral neoformations such as hyperplastic gingival lesions.

  12. Comparison of commercial fibrin sealants in facelift surgery: a prospective study

    Directory of Open Access Journals (Sweden)

    Botti G

    2013-11-01

    Full Text Available Giovanni Botti,1 Michele Pascali,2 Chiara Botti,1 Florian Bodog,3 Pietro Gentile,2 Valerio Cervelli2 1Villa Bella Clinic, Salò, 2Department of Plastic and Reconstructive Surgery, University of Rome Tor Vergata, Italy; 3University of Oradea, Oradea, Romania Background: The aim of this study was to compare the effects of two types of fibrin glue in patients undergoing facelift surgery. Methods: A prospective, controlled "right-left side" study was carried out in 20 patients. The two fibrin sealants used were Quixil® and Tissucol®. The two sealants were used at the same time, ie, one on one side of the face and the other on the contralateral side. Comparisons were made with regard to rates of hematoma and seroma, degree of induration, edema, ecchymosis, pain levels, and patient satisfaction. Results: The results were almost equivalent. The only exception was a significant (40 mL hematoma in a patient treated with Quixil. Bleeding was most likely due to a sudden rise in blood pressure during the immediate postoperative period. However, it must be emphasized that, while Tissucol actually seals the undermined area, thus virtually eliminating the dead space, Quixil acts differently, in that its effectiveness in preventing hematoma is linked mainly to its hemostatic effect. Conclusion: The two fibrin sealants used were nearly identical with regard to patient safety and quality of the result. Nevertheless, it is noted that, while Tissucol has both hemostatic and "gluing" effects, Quixil is mainly effective in securing hemostasis. Keywords: facelift surgery, rhytidectomy, fibrin sealants, hematoma

  13. Application of fibrin glue with bandage contact lens in pterygium surgery

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2014-05-01

    Full Text Available AIM: To explore the efficacy of fibrin glue with bandage contact lens for pain relief after pterygium surgery performed with limbal autograft transplantation.METHODS: A prospective clinical trial was carried out in 52 patients(72 eyesoperated for primary nasal pterygium. All patients were randomly divided into the fibrin glue with bandage contact lens group(experimental group, 28 cases, 38 eyesand suture group(control group, 24 cases, 34 eyes. Autologous limbal graft taken from the superotemporal limbus was used to cover the sclera after pterygium excision under local anesthesia with 20g/L lidocaine. In experimental group, the transplant was attached to the sclera with fibrin tissue adhesive and in control group with 10-0 Virgin silk sutures. Experimental group weared bandage contact lens after surgery while the control group did not. The degree of pain after surgery was evaluated at 1, 2, 3, 5 and 7d after surgery. Follow-up was 6mo, matching degree of graft and complication such as infection, relapse, implant healing badness and subconjunctival cyst were mainly observed and recorded.RESULTS: The pain index scores of the experimental group were significantly less than those of control group(all P=0.000. In observation period, all conjunctival autografts in both groups were successfully attached and were intact without falling off, dissolution or recurrence and there were no complications such as infection, relapse, implant healing badness and subconjunctival cyst.CONCLUSION: Fibrin glue with bandage contact lens could significantly release pain response afterpterygium excision surgery.

  14. A Novel Technique Using a Protection Filter During Fibrin Sheath Removal for Implanted Venous Access Device Dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Sotiriadis, Charalampos; Hajdu, Steven David [University Hospital of Lausanne, Cardiothoracic and Vascular Unit, Department of Radiology (Switzerland); Degrauwe, Sophie [University Hospital of Lausanne, Department of Cardiology (Switzerland); Barras, Heloise; Qanadli, Salah Dine, E-mail: salah.qanadli@chuv.ch [University Hospital of Lausanne, Cardiothoracic and Vascular Unit, Department of Radiology (Switzerland)

    2016-08-15

    With the increased use of implanted venous access devices (IVADs) for continuous long-term venous access, several techniques such as percutaneous endovascular fibrin sheath removal, have been described, to maintain catheter function. Most standard techniques do not capture the stripped fibrin sheath, which is subsequently released in the pulmonary circulation and may lead to symptomatic pulmonary embolism. The presented case describes an endovascular technique which includes stripping, capture, and removal of fibrin sheath using a novel filter device. A 64-year-old woman presented with IVAD dysfunction. Stripping was performed using a co-axial snare to the filter to capture the fibrin sheath. The captured fragment was subsequently removed for visual and pathological verification. No immediate complication was observed and the patient was discharged the day of the procedure.

  15. A spectrophotometer-based diffusivity assay reveals that diffusion hindrance of small molecules in extracellular matrix gels used in 3D cultures is dominated by viscous effects.

    Science.gov (United States)

    Galgoczy, Roland; Pastor, Isabel; Colom, Adai; Giménez, Alicia; Mas, Francesc; Alcaraz, Jordi

    2014-08-01

    The design of 3D culture studies remains challenging due to the limited understanding of extracellular matrix (ECM)-dependent hindered diffusion and the lack of simple diffusivity assays. To address these limitations, we set up a cost-effective diffusivity assay based on a Transwell plate and the spectrophotometer of a Microplate Reader, which are readily accessible to cell biology groups. The spectrophotometer-based assay was used to assess the apparent diffusivity D of FITC-dextrans with molecular weight (4-70kDa) spanning the physiological range of signaling factors in a panel of acellular ECM gels including Matrigel, fibrin and type I collagen. Despite their technical differences, D data exhibited ∼15% relative difference with respect to FRAP measurements. Our results revealed that diffusion hindrance of small particles is controlled by the enhanced viscosity of the ECM gel in conformance with the Stokes-Einstein equation rather than by geometrical factors. Moreover, we provided a strong rationale that the enhanced ECM viscosity is largely contributed to by unassembled ECM macromolecules. We also reported that gels with the lowest D exhibited diffusion hindrance closest to the large physiologic hindrance of brain tissue, which has a typical pore size much smaller than ECM gels. Conversely, sparse gels (≤1mg/ml), which are extensively used in 3D cultures, failed to reproduce the hindered diffusion of tissues, thereby supporting that dense (but not sparse) ECM gels are suitable tissue surrogates in terms of macromolecular transport. Finally, the consequences of reduced diffusivity in terms of optimizing the design of 3D culture experiments were addressed in detail. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. EGSnrc calculated and MRI-polymer gel dosimeter measured dose distribution of gamma knife in presence of inhomogeneities

    International Nuclear Information System (INIS)

    Allahverdi Pourfallah, T.; Allahverdi, M.; Riahi Alam, N.; Ay, M.; Zahmatkesh, M.; Ibbott, J.S.

    2008-01-01

    Stereotactic gamma-knife radiosurgery plays an important role in managing small intracranial brain lesions. Currently, polymer gel dosimetry is still the only dosimetry method for directly measuring three-dimensional dose distributions. polymer gel dosimeters are tissue equivalent and can act as a phantom material. In this study effects of inhomogeneities on those distributions have been investigated using both EGSnrc calculation and PAGAT polymer gel dosimeter. (author)

  17. Binding of thrombin-activated platelets to a fibrin scaffold through α(IIb)β₃ evokes phosphatidylserine exposure on their cell surface.

    Science.gov (United States)

    Brzoska, Tomasz; Suzuki, Yuko; Mogami, Hideo; Sano, Hideto; Urano, Tetsumei

    2013-01-01

    Recently, by employing intra-vital confocal microscopy, we demonstrated that platelets expose phosphatidylserine (PS) and fibrin accumulate only in the center of the thrombus but not in its periphery. To address the question how exposure of platelet anionic phospholipids is regulated within the thrombus, an in-vitro experiment using diluted platelet-rich plasma was employed, in which the fibrin network was formed in the presence of platelets, and PS exposure on the platelet surface was analyzed using Confocal Laser Scanning Microscopy. Almost all platelets exposed PS after treatment with tissue factor, thrombin or ionomycin. Argatroban abrogated fibrin network formation in all samples, however, platelet PS exposure was inhibited only in tissue factor- and thrombin-treated samples but not in ionomycin-treated samples. FK633, an α(IIb)β₃ antagonist, and cytochalasin B impaired platelet binding to the fibrin scaffold and significantly reduced PS exposure evoked by thrombin. Gly-Pro-Arg-Pro amide abrogated not only fibrin network formation, but also PS exposure on platelets without suppressing platelet binding to fibrin/fibrinogen. These results suggest that outside-in signals in platelets generated by their binding to the rigid fibrin network are essential for PS exposure after thrombin treatment.

  18. Adipose-Derived-Stem-Cell-Seeded Fibrin Matrices for Periodontal Ligament Engineering: The Need for Dynamic Strain

    NARCIS (Netherlands)

    de Jong, Thijs; Oostendorp, Corien; Bakker, Astrid D.; van Kuppevelt, Toin H.; Smit, Theo H.

    2017-01-01

    Introduction: The periodontal ligament (PDL) connects the tooth to the alveolar bone. For PDL regeneration after tissue damage, we propose human adipose-derived stem cells (hASCs) embedded in fibrin. We showed previously that hASCs in fibrin extensively produce collagen, but in a non-functional,

  19. Purification and characterization of novel fibrin(ogen)olytic protease from Curcuma aromatica Salisb.: Role in hemostasis.

    Science.gov (United States)

    Shivalingu, B R; Vivek, H K; Priya, B S; Soujanya, K N; Swamy, S Nanjunda

    2016-12-01

    The proteases from turmeric species have procoagulant and fibrinogenolytic activity. This provides a scientific basis for traditional use of turmeric to stop bleeding and promote wound healing processes. Our previous studies revealed that fibrinogenolytic action of crude enzyme fraction of Curcuma aromatica Salisb., was found to be more influential than those of Curcuma longa L., Curcuma caesia Roxb., Curcuma amada Roxb. and Curcuma zedoria (Christm.) Roscoe. Hence, the purpose of this study is to purify and characterize protease from C. aromatica and to explore its role in wound healing process. The protease was purified by Sephadex G-50 gel permeation chromatography. Peak with potent proteolytic activity was subjected to rechromatography and then checked for homogeneity by SDS-PAGE and native PAGE. Furthermore purity of the peak was assessed by RP-HPLC and MALDI-TOF. The biochemical properties, type of protease, kinetic studies, fibrinogenolytic, coagulant and fibrinolytic activities were carried out. The two proteolytic peaks were fractionated in gel permeation chromatography. Among these, the peak-II showed potent proteolytic activity with specific activity of 10units/mg/min and named as C. aromatica protease-II (CAP-II). This protein resolved into a single sharp band both in SDS-PAGE (reducing and non-reducing) as well as in native (acidic) PAGE. It is a monomeric protein, showing sharp peak in RP-HPLC and its relative molecular mass was found to be 12.378kDa. The caseinolytic and fibrinolytic activity of CAP-II was completely inhibited by phenylmethylsulfonylfluoride (PMSF). The CAP-II exhibited optimum temperature of 45°C and optimum pH of 7.5. The Km and Vmax of CAP-II was found to be 1.616µg and 1.62units/mg/min respectively. The CAP-II showed hydrolysis of all three subunits of fibrinogen in the order Aα>Bß>γ. The CAP-II exhibited strong procoagulant activity by reducing the human plasma clotting time. It also showed fibrinolytic activity by complete

  20. Effect of Titanium-prepared Platelet-rich Fibrin Treatment on the ...

    African Journals Online (AJOL)

    Effect of Titanium-prepared Platelet-rich Fibrin Treatment on the Angiogenic Biomarkers in Gingival Crevicular Fluid in Infrabony Defects of Patients with Chronic Periodontitis: A Randomized Controlled Clinical Trial.

  1. Three-dimensional architecture and cell composition of a Choukroun's platelet-rich fibrin clot and membrane.

    Science.gov (United States)

    Dohan Ehrenfest, David M; Del Corso, Marco; Diss, Antoine; Mouhyi, Jaafar; Charrier, Jean-Baptiste

    2010-04-01

    Platelet-rich fibrin (PRF; Choukroun's technique) is a second-generation platelet concentrate for surgical use. This easy protocol allows the production of leukocyte and platelet-rich fibrin clots and membranes starting from 10-ml blood samples. The purposes of this study were to determine the cell composition and three-dimensional organization of this autologous biomaterial and to evaluate the influence of different collection tubes (dry glass or glass-coated plastic tubes) and compression procedures (forcible or soft) on the final PRF-membrane architecture. After centrifugation, blood analyses were performed on the residual waste plasmatic layers after collecting PRF clots. The PRF clots and membranes were processed for examination by light microscopy and scanning electron microscopy. Approximately 97% of the platelets and >50% of the leukocytes were concentrated in the PRF clot and showed a specific three-dimensional distribution, depending on the centrifugation forces. Platelets and fibrin formed large clusters of coagulation in the first millimeters of the membrane beyond the red blood cell base. The fibrin network was very mature and dense. Moreover, there was no significant difference in the PRF architecture between groups using the different tested collection tubes and compression techniques, even if these two parameters could have influenced the growth factor content and biologic matrix properties. The PRF protocol concentrated most platelets and leukocytes from a blood harvest into a single autologous fibrin biomaterial. This protocol offers reproducible results as long as the main production principles are respected.

  2. Efficacy of platelet-rich fibrin vs. enamel matrix derivative in the treatment of periodontal intrabony defects: a clinical and cone beam computed tomography study.

    Science.gov (United States)

    Gupta, Swyeta Jain; Jhingran, Rajesh; Gupta, Vivek; Bains, Vivek Kumar; Madan, Rohit; Rizvi, Iram

    2014-07-01

    To evaluate and compare the efficacy of platelet-rich fibrin (PRF) with enamel matrix derivative (EMD; Emdogain) in the treatment of periodontal intrabony defects in patients with chronic periodontitis, six months after surgery. Forty-four (44) intrabony defects in 30 patients (15 males) were randomly allocated into two treatment groups: EMD (n = 22) and PRF (n = 22). Measurement of the defects was done using clinical and cone beam computed tomography at baseline and 6 months. Clinical and radiographic parameters such as probing depth, clinical attachment level, intrabony defect depth and defect angle, were recorded at baseline and 6 months post-operatively. Within group change was evaluated using the Wilcoxon signed rank test. Intergroup comparisons were made using the Mann-Whitney U test. Postsurgical measurements revealed that there was an equal reduction in probing depth and a greater but statistically non-significant attachment gain for the Emdogain group when compared to the platelet-rich fibrin group. The Emdogain group presented with significantly greater percentage defect resolution (43.07% ± 12.21) than did the platelet-rich fibrin group (32.41% ± 14.61). Post-operatively the changes in defect width and defect angle were significant in both groups, but upon intergroup comparison they were found to be statistically non-significantly different. Both Emdogain and platelet-rich fibrin were effective in the regeneration of intrabony defects. Emdogain was significantly superior in terms of percentage defect resolution.

  3. Fibrin sealant for mesh fixation in laparoscopic groin hernia repair does not increase long-term recurrence

    DEFF Research Database (Denmark)

    Fenger, Andreas Qwist; Helvind, Neel Maria; Pommergaard, Hans-Christian

    2016-01-01

    BACKGROUND: Methods of groin hernia repair include laparoscopic techniques using tissue-penetrating mesh fixation or non-penetrating fixation. Concerns regarding hernia repair include postoperative chronic pain, sexual dysfunction, and recurrence. Earlier estimations of recurrence rates have......) laparoscopic groin hernia repair using either fibrin sealant or tacks for mesh fixation. METHODS: This study used data from the Danish Hernia Database to create the following cohort: All patients operated laparoscopically for primary groin hernia with a TAPP procedure using fibrin sealant for mesh fixation...... difference in long-term reoperation rates and clinical recurrences in patients undergoing TAPP repair with meshes fixated with fibrin sealant compared with tacks....

  4. Binding of Thrombin-Activated Platelets to a Fibrin Scaffold through αIIbβ3 Evokes Phosphatidylserine Exposure on Their Cell Surface

    Science.gov (United States)

    Brzoska, Tomasz; Suzuki, Yuko; Mogami, Hideo; Sano, Hideto; Urano, Tetsumei

    2013-01-01

    Recently, by employing intra-vital confocal microscopy, we demonstrated that platelets expose phosphatidylserine (PS) and fibrin accumulate only in the center of the thrombus but not in its periphery. To address the question how exposure of platelet anionic phospholipids is regulated within the thrombus, an in-vitro experiment using diluted platelet-rich plasma was employed, in which the fibrin network was formed in the presence of platelets, and PS exposure on the platelet surface was analyzed using Confocal Laser Scanning Microscopy. Almost all platelets exposed PS after treatment with tissue factor, thrombin or ionomycin. Argatroban abrogated fibrin network formation in all samples, however, platelet PS exposure was inhibited only in tissue factor- and thrombin-treated samples but not in ionomycin-treated samples. FK633, an αIIbβ3 antagonist, and cytochalasin B impaired platelet binding to the fibrin scaffold and significantly reduced PS exposure evoked by thrombin. Gly-Pro-Arg-Pro amide abrogated not only fibrin network formation, but also PS exposure on platelets without suppressing platelet binding to fibrin/fibrinogen. These results suggest that outside-in signals in platelets generated by their binding to the rigid fibrin network are essential for PS exposure after thrombin treatment. PMID:23383331

  5. Binding of thrombin-activated platelets to a fibrin scaffold through α(IIbβ₃ evokes phosphatidylserine exposure on their cell surface.

    Directory of Open Access Journals (Sweden)

    Tomasz Brzoska

    Full Text Available Recently, by employing intra-vital confocal microscopy, we demonstrated that platelets expose phosphatidylserine (PS and fibrin accumulate only in the center of the thrombus but not in its periphery. To address the question how exposure of platelet anionic phospholipids is regulated within the thrombus, an in-vitro experiment using diluted platelet-rich plasma was employed, in which the fibrin network was formed in the presence of platelets, and PS exposure on the platelet surface was analyzed using Confocal Laser Scanning Microscopy. Almost all platelets exposed PS after treatment with tissue factor, thrombin or ionomycin. Argatroban abrogated fibrin network formation in all samples, however, platelet PS exposure was inhibited only in tissue factor- and thrombin-treated samples but not in ionomycin-treated samples. FK633, an α(IIbβ₃ antagonist, and cytochalasin B impaired platelet binding to the fibrin scaffold and significantly reduced PS exposure evoked by thrombin. Gly-Pro-Arg-Pro amide abrogated not only fibrin network formation, but also PS exposure on platelets without suppressing platelet binding to fibrin/fibrinogen. These results suggest that outside-in signals in platelets generated by their binding to the rigid fibrin network are essential for PS exposure after thrombin treatment.

  6. Subconjunctival PRGF Fibrin Membrane as an Adjuvant to Nonpenetrating Deep Sclerectomy: A 2-Year Pilot Study.

    Science.gov (United States)

    Rodríguez-Agirretxe, Iñaki; Freire, Vanesa; Muruzabal, Francisco; Orive, Gorka; Anitua, Eduardo; Díez-Feijóo, Elio; Acera, Arantxa

    2018-01-01

    To evaluate the potential role of the autologous PRGF (plasma rich in growth factors) fibrin membrane in tissue regeneration after glaucoma filtering surgery. Ten patients with medically uncontrolled primary open-angle glaucoma underwent nonpenetrating deep sclerectomy and were treated with PRGF fibrin membrane as adjuvant. Intraocular pressure reduction was the primary outcome. This variable was measured preoperatively and also at each follow-up visit. Secondary outcomes included the number of antiglaucoma medications, anterior segment optical coherence tomography bleb examination, photographic bleb evaluation, and subjective clinical symptomatology evaluation. The surgical technique showed a significant reduction (p PRGF-Endoret treatment could promote ocular surface regeneration after glaucoma surgery, enhancing the surgery success rates and reducing the need for postoperative medications. It is important to highlight that this is a preliminary study and some large clinical studies are necessary to verify these results. © 2017 S. Karger AG, Basel.

  7. Platelet-rich fibrin versus albumin in surgical wound repair: a randomized trial with paired design

    DEFF Research Database (Denmark)

    Danielsen, Patricia L; Ågren, Sven Per Magnus; Jørgensen, Lars Nannestad

    2010-01-01

    To study the effects of autologous platelet-rich fibrin (PRF) versus human albumin on incisional wound breaking strength and subcutaneous collagen deposition in patients undergoing laparoscopic cholecystectomy in a randomized trial.......To study the effects of autologous platelet-rich fibrin (PRF) versus human albumin on incisional wound breaking strength and subcutaneous collagen deposition in patients undergoing laparoscopic cholecystectomy in a randomized trial....

  8. Hyaline Articular Matrix Formed by Dynamic Self-Regenerating Cartilage and Hydrogels.

    Science.gov (United States)

    Meppelink, Amanda M; Zhao, Xing; Griffin, Darvin J; Erali, Richard; Gill, Thomas J; Bonassar, Lawrence J; Redmond, Robert W; Randolph, Mark A

    2016-07-01

    Injuries to the articular cartilage surface are challenging to repair because cartilage possesses a limited capacity for self-repair. The outcomes of current clinical procedures aimed to address these injuries are inconsistent and unsatisfactory. We have developed a novel method for generating hyaline articular cartilage to improve the outcome of joint surface repair. A suspension of 10(7) swine chondrocytes was cultured under reciprocating motion for 14 days. The resulting dynamic self-regenerating cartilage (dSRC) was placed in a cartilage ring and capped with fibrin and collagen gel. A control group consisted of chondrocytes encapsulated in fibrin gel. Constructs were implanted subcutaneously in nude mice and harvested after 6 weeks. Gross, histological, immunohistochemical, biochemical, and biomechanical analyses were performed. In swine patellar groove, dSRC was implanted into osteochondral defects capped with collagen gel and compared to defects filled with osteochondral plugs, collagen gel, or left empty after 6 weeks. In mice, the fibrin- and collagen-capped dSRC constructs showed enhanced contiguous cartilage matrix formation over the control of cells encapsulated in fibrin gel. Biochemically, the fibrin and collagen gel dSRC groups were statistically improved in glycosaminoglycan and hydroxyproline content compared to the control. There was no statistical difference in the biomechanical data between the dSRC groups and the control. The swine model also showed contiguous cartilage matrix in the dSRC group but not in the collagen gel and empty defects. These data demonstrate the survivability and successful matrix formation of dSRC under the mechanical forces experienced by normal hyaline cartilage in the knee joint. The results from this study demonstrate that dSRC capped with hydrogels successfully engineers contiguous articular cartilage matrix in both nonload-bearing and load-bearing environments.

  9. Comparison of water gel desserts from fish skin and pork gelatins using instrumental measurements.

    Science.gov (United States)

    Zhou, Peng; Regenstein, Joe M

    2007-05-01

    The objective of this study was to compare water gel desserts from various gelatins using instrumental measurements. The puncture test and texture profile analysis (TPA) with compression were determined at 25% and 75% deformation; the melting properties were determined rheologically by monitoring the change of storage modulus (G') with increasing temperature. The measurements with 25% deformation were always nondestructive, while measurements with 75% deformation were mostly destructive. Desserts made from Alaska pollock gelatin (AG) or gelatin mixtures containing AG were more resistant to the destruction caused by the large deformation than tilapia gelatin and pork gelatins. In addition, the gel dessert made from AG melted at a lower temperature than those from tilapia skin gelatin and pork gelatins, while desserts made from gelatin mixtures reflected the melting properties of the separate gelatins.

  10. The use of snake venom derived fibrin glue in hysterorrhaphy of ovine caesarean surgery

    OpenAIRE

    CHALHOUB, M.; PRESTES, N. C.; LOPES, M. D.; ROCHA, N. S.; THOMAZINI-SANTOS, I. A.; MENDES-GIANNINI, M.J.

    2000-01-01

    Fibrin glue has been used on its own or in conjunction with suturing materials to promote hemostasis, reduce adherence, strengthen the wound site, and improve healing. Snake venom derived fibrin glue was evaluated as an alternative to conventional uterine suturing after ovine caesarean surgery. Twenty-eight pregnant ewes of known mating date were used. The animals submitted to conventional caesarean sections showed a better wound healing process. As expected, all the operated animals had reta...

  11. In situ observation of sol-gel transition of agarose aqueous solution by fluorescence measurement.

    Science.gov (United States)

    Wang, Zheng; Yang, Kun; Li, Haining; Yuan, Chaosheng; Zhu, Xiang; Huang, Haijun; Wang, Yongqiang; Su, Lei; Fang, Yapeng

    2018-06-01

    Sol-gel transition behavior of agarose aqueous solution was investigated by using rheology and fluorescence measurement. On heating, the storage modulus G' decreased gradually, then deviated abruptly at the temperature of about 65°C, and finally decreased slowly again. For fluorescence measurement, the phase transition point kept almost at the temperature of 65°C, which was consistent with that in rheology measurement. Upon compression, it was indicated that the fluorescence lifetime for the probe in the agarose aqueous solution showed a dramatic change in the vicinity of the phase transition point. T vs. P phase diagram of agarose aqueous solution was constructed, which showed that the melting point was an increasing function of pressure. Based on the phase diagram, the agarose gels were prepared by cooling under atmospheric pressure and the pressure of 300MPa, respectively. From the result of the recovered samples studied by optical rheometry, it was found that agarose gel prepared under high pressure had a higher elasticity and lower viscosity index, compared with that under atmospheric pressure. It could be speculated that such kinds of properties might be attributed to the smaller pore size during gelation under high pressure. Copyright © 2018. Published by Elsevier B.V.

  12. Pancreatic fistula after laparoscopic splenectomy in patients with hypersplenism due to liver cirrhosis: effect of fibrin glue and polyglycolic acid felt on prophylaxis of postoperative complications.

    Science.gov (United States)

    Tsutsumi, Norifumi; Tomikawa, Morimasa; Akahoshi, Tomohiko; Kawanaka, Hirofumi; Ota, Mitsuhiko; Sakaguchi, Yoshihisa; Kusumoto, Tetsuya; Ikejiri, Koji; Hashizume, Makoto; Maehara, Yoshihiko

    2016-11-01

    This study aimed to determine the effect of fibrin glue and polyglycolic acid (PGA) felt on prevention of pancreatic fistula (PF) after laparoscopic splenectomy in patients with hypersplenism due to liver cirrhosis. Fifty consecutive patients were enrolled in this prospective study. Twenty-three patients underwent laparoscopic splenectomy with a fibrin sheet (fibrin sheet group). The sealing ability of each treatment was evaluated by an ex vivo pressure test model. Based on the results from ex vivo experiments, 27 patients received prophylaxis using fibrin glue and PGA felt (PGA with fibrin group). The primary endpoint was the incidence of PF. Significantly more (5, 22%) patients developed PF in the fibrin sheet group than in the PGA with fibrin group (0%, P = .037). Our new application of fibrin glue and PGA felt is an effective prophylactic procedure for preventing development of PF after laparoscopic splenectomy. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Platelet-rich fibrin prepared from stored whole-blood samples.

    Science.gov (United States)

    Isobe, Kazushige; Suzuki, Masashi; Watanabe, Taisuke; Kitamura, Yutaka; Suzuki, Taiji; Kawabata, Hideo; Nakamura, Masayuki; Okudera, Toshimitsu; Okudera, Hajime; Uematsu, Kohya; Nakata, Koh; Tanaka, Takaaki; Kawase, Tomoyuki

    2017-12-01

    In regenerative therapy, self-clotted platelet concentrates, such as platelet-rich fibrin (PRF), are generally prepared on-site and are immediately used for treatment. If blood samples or prepared clots can be preserved for several days, their clinical applicability will expand. Here, we prepared PRF from stored whole-blood samples and examined their characteristics. Blood samples were collected from non-smoking, healthy male donors (aged 27-67 years, N = 6), and PRF clots were prepared immediately or after storage for 1-2 days. Fibrin fiber was examined by scanning electron microscopy. Bioactivity was evaluated by means of a bioassay system involving human periosteal cells, whereas PDGF-BB concentrations were determined by an enzyme-linked immunosorbent assay. Addition of optimal amounts of a 10% CaCl 2 solution restored the coagulative ability of whole-blood samples that contained an anticoagulant (acid citrate dextrose) and were stored for up to 2 days at ambient temperature. In PRF clots prepared from the stored whole-blood samples, the thickness and cross-links of fibrin fibers were almost identical to those of freshly prepared PRF clots. PDGF-BB concentrations in the PRF extract were significantly lower in stored whole-blood samples than in fresh samples; however, both extracts had similar stimulatory effects on periosteal-cell proliferation. Quality of PRF clots prepared from stored whole-blood samples is not reduced significantly and can be ensured for use in regenerative therapy. Therefore, the proposed method enables a more flexible treatment schedule and choice of a more suitable platelet concentrate immediately before treatment, not after blood collection.

  14. Simultaneous sinus lift and implantation using platelet-rich fibrin as sole grafting material.

    Science.gov (United States)

    Jeong, Seung-Mi; Lee, Chun-Ui; Son, Jeong-Seog; Oh, Ji-Hyeon; Fang, Yiqin; Choi, Byung-Ho

    2014-09-01

    Recently, several authors have shown that simultaneous sinus lift and implantation using autologous platelet-rich fibrin as the sole filling material is a reliable procedure promoting bone augmentation in the maxillary sinus. The aim of this study was to examine the effect of simultaneous sinus lift and implantation using platelet-rich fibrin as the sole grafting material on bone formation in a canine sinus model. An implant was placed after sinus membrane elevation in the maxillary sinus of six adult female mongrel dogs. The resulting space between the membrane and sinus floor was filled with autologous platelet-rich fibrin retrieved from each dog. The implants were left in place for six months. Bone tissue was seen at the lower part of the implants introduced into the sinus cavity. The height of the newly formed bone around the implants ranged from 0 mm to 4.9 mm (mean; 2.6 ± 2.0 mm) on the buccal side and from 0 mm to 4.2 mm (mean; 1.3 ± 1.8 mm) on the palatal side. The findings from this study suggest that simultaneous sinus lift and implantation using platelet-rich fibrin as sole grafting material is not a predictable and reproducible procedure, especially with respect to the bone formation around the implants in the sinus cavity. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. All rights reserved.

  15. Selective inhibition by a synthetic hirudin peptide of fibrin-dependent thrombosis in baboons

    International Nuclear Information System (INIS)

    Cadroy, Y.; Hanson, S.R.; Harker, L.A.; Maraganore, J.M.

    1991-01-01

    To determine the importance of the thrombin substrate recognition exosite for fibrinogen binding in the formation of both arterial and venous thrombi the authors evaluated the antithrombotic effects of the tyrosine-sulfated dodecapeptide from residues 53-64 of hirudin (H peptide) in a nonhuman primate model. This peptide was studied because it inhibits thrombin cleavages of fibrinogen by simple competition without blocking enzyme catalytic-site function. When an exteriorized arteriovenous access shunt model was used in baboons (Papio anubis), thrombus formation was induced by placing a thrombogenic device made of (i) a segment of tubing coated covalently with type I collagen, which generated platelet-rich thrombi under arterial flow conditions, and (ii) two subsequent annular regions of flow expansion that produced fibrin-rich thrombi typically associated with venous valves and veins. Thrombus formation was quantified by measurements of 111 In-labeled platelet and 125 I-labeled fibrinogen deposition in both arterial-flow and venous-flow portions of the device. These finding suggest that, by competitive inhibition of fibrinogen binding to thrombin, fibrin-rich venous-type thrombus formation may be selectively prevented. This strategy may be therapeutically attractive for preserving normal platelet function when conventional anticoagulant therapy is contraindicated

  16. Effect of Titanium-prepared Platelet-rich Fibrin Treatment on the ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... Defects of Patients with Chronic Periodontitis: A Randomized. Controlled ... Faculty of Dentistry Department of Periodontology, Kirikkale. University ..... using leukocyte and platelet-rich fibrin: A report of a case. Case. Rep Dent ...

  17. Data on final calcium concentration in native gel reagents determined accurately through inductively coupled plasma measurements

    Directory of Open Access Journals (Sweden)

    Jeffrey Viviano

    2016-03-01

    Full Text Available In this article we present data on the concentration of calcium as determined by Inductively Coupled Plasma (ICP measurements. Calcium was estimated in the reagents used for native gel electrophoresis of Neuronal Calcium Sensor (NCS proteins. NCS proteins exhibit calcium-dependent mobility shift in native gels. The sensitivity of this shift to calcium necessitated a precise determination of calcium concentrations in all reagents used. We determined the calcium concentrations in different components used along with the samples in the native gel experiments. These were: 20 mM Tris pH 7.5, loading dye and running buffer, with distilled water as reference. Calcium determinations were through ICP measurements. It was found that the running buffer contained calcium (244 nM over the blank. Keywords: Neuronal calcium sensor proteins, Electrophoresis, Mobility shift, Calcium, Magnesium

  18. Introduction of a potent single-donor fibrin glue for vascular anastomosis: An animal study

    Directory of Open Access Journals (Sweden)

    Mehdi Rasti Ardakani

    2012-01-01

    Full Text Available Background: Vascular anastomosis is considered as a difficult surgical procedure. Although different alternative methods have been tried to tackle these difficulties, none were found to be successful. Commercial fibrin glue has recently been used for vascular anastomosis. However, it did not gain popularity due to some limitations such as low tensile strength, rapid removal by the immune system, and risk of transmission of blood-borne viral infections. In this article, we presented a novel method for producing single-donor human fibrin glue and determined its success rate for vascular anastomosis in an animal model. Materials ans Methods : In this study, 3 mL of single-donor fibrin sealant was prepared from 150 mL of whole blood containing 50-70 mg/mL of fibrinogen. The study was performed on 10 dogs and 5 cats. After transection of the carotid artery, both ends were anastomosed by means of 3-4 sutures (Prolene 8-0. The suture line was then sealed with one layer of the new fibrin sealant. After 3-8 weeks, the site of anastomosis was evaluated angiographically and morphologically for healing and possible complications such as thrombosis or aneurysm. Results: In evaluations 3 weeks after the surgery, all arterial anastomoses were patent in dogs, but some degree of subintimal hyperplasia was noted. After 8 weeks, all anastomoses were patent and the degree of subintimal hyperplasia was decreased. In cats on the other hand, after 4 weeks, all anastomoses were patent and subintimal hyperplasia was absent. Conclusions: Single-donor fibrin glue was a quite reliable and practical alternative to minimize suturing and therefore operative time in our animal model. This sealant can easily be obtained from the patient′s whole blood. Its application in humans would require further studies.

  19. [Conservative anal fistula treatment with collagenic plug and human fibrin sealant. Preliminary results].

    Science.gov (United States)

    Gubitosi, A; Moccia, G; Malinconico, F A; Docimo, G; Ruggiero, R; Iside, G; Avenia, N; Docimo, L; Foroni, F; Gilio, F; Sparavigna, L; Agresti, M

    2009-01-01

    The authors, on the basis of a long clinical experience with human fibrin glue in general surgery, compared two different extracellular matrix (collagen), Surgisis and TissueDura, with human fibrin glue, applied during the operation, and sometimes in postoperative, to obtain the healing of perianal fistulas. The collagenic extracellular matrix provides, according to the rationale suggested, an optimal three-dimensional structure for the fibroblastic implant and neoangiogenesis, hence for the fistula "fibrotizzation" and closure. The encouraging results for transphincteric fistulas and a simple and easy technique push to researchers on samples statistically significant.

  20. Platelets Drive Thrombus Propagation in a Hematocrit and Glycoprotein VI-Dependent Manner in an In Vitro Venous Thrombosis Model.

    Science.gov (United States)

    Lehmann, Marcus; Schoeman, Rogier M; Krohl, Patrick J; Wallbank, Alison M; Samaniuk, Joseph R; Jandrot-Perrus, Martine; Neeves, Keith B

    2018-05-01

    The objective of this study was to measure the role of platelets and red blood cells on thrombus propagation in an in vitro model of venous valvular stasis. A microfluidic model with dimensional similarity to human venous valves consists of a sinus distal to a sudden expansion, where for sufficiently high Reynolds numbers, 2 countercurrent vortices arise because of flow separation. The primary vortex is defined by the points of flow separation and reattachment. A secondary vortex forms in the deepest recess of the valve pocket characterized by low shear rates. An initial fibrin gel formed within the secondary vortex of a tissue factor-coated valve sinus. Platelets accumulated at the interface of the fibrin gel and the primary vortex. Red blood cells at physiological hematocrits were necessary to provide an adequate flux of platelets to support thrombus growth out of the valve sinus. A subpopulation of platelets that adhered to fibrin expose phosphatidylserine. Platelet-dependent thrombus growth was attenuated by inhibition of glycoprotein VI with a blocking Fab fragment or D-dimer. A 3-step process regulated by hemodynamics was necessary for robust thrombus propagation: First, immobilized tissue factor initiates coagulation and fibrin deposition within a low flow niche defined by a secondary vortex in the pocket of a model venous valve. Second, a primary vortex delivers platelets to the fibrin interface in a red blood cell-dependent manner. Third, platelets adhere to fibrin, activate through glycoprotein VI, express phosphatidylserine, and subsequently promote thrombus growth beyond the valve sinus and into the bulk flow. © 2018 American Heart Association, Inc.

  1. Lyophilized platelet-rich fibrin (PRF) promotes craniofacial bone regeneration through Runx2.

    Science.gov (United States)

    Li, Qi; Reed, David A; Min, Liu; Gopinathan, Gokul; Li, Steve; Dangaria, Smit J; Li, Leo; Geng, Yajun; Galang, Maria-Therese; Gajendrareddy, Praveen; Zhou, Yanmin; Luan, Xianghong; Diekwisch, Thomas G H

    2014-05-14

    Freeze-drying is an effective means to control scaffold pore size and preserve its composition. The purpose of the present study was to determine the applicability of lyophilized Platelet-rich fibrin (LPRF) as a scaffold for craniofacial tissue regeneration and to compare its biological effects with commonly used fresh Platelet-rich fibrin (PRF). LPRF caused a 4.8-fold±0.4-fold elevation in Runt-related transcription factor 2 (Runx2) expression in alveolar bone cells, compared to a 3.6-fold±0.2-fold increase when using fresh PRF, and a more than 10-fold rise of alkaline phosphatase levels and mineralization markers. LPRF-induced Runx2 expression only occurred in alveolar bone and not in periodontal or dental follicle cells. LPRF also caused a 1.6-fold increase in osteoblast proliferation (pfibrin, and 16% without scaffold. Moreover, LPRF thickened the trabecular diameter by 25% when compared to fresh PRF and fibrin, and only LPRF and fresh PRF resulted in the formation of interconnected trabeculae across the defect. Together, these studies support the application of lyophilized PRF as a biomimetic scaffold for craniofacial bone regeneration and mineralized tissue engineering.

  2. Radiation-induced DNA damage and repair in radiosensitive and radioresistant human tumour cells measured by field inversion gel electrophoresis

    International Nuclear Information System (INIS)

    Smeets, M.F.M.A.; Mooren, E.H.M.; Begg, A.C.

    1993-01-01

    Radiation-induced DNA damage induction and repair was measured in two human squamous carcinoma cell lines with differing radiosensitivities. Experiments were carried out with field inversion gel electrophoresis (FIGE), adapted to measure DNA double strand break (DSB) induction and repair in unlabelled cells. The sensitivity of the method was increased by introducing a hybridization membrane into the agarose gel. Damaged DNA accumulated on one spot on the membrane resulting in high local concentrations. This DNA was quantified using radioactively-labelled total human DNA as a probe. Radiosensitivity differences at physiological temperatures could not be explained by differences in either induction or repair of DNA damage as measured by pulsed field gel electrophoresis. (author)

  3. Availability of the B beta(15-21) epitope on cross-linked human fibrin and its plasmic degradation products

    Science.gov (United States)

    Chen, F.; Haber, E.; Matsueda, G. R.

    1992-01-01

    The binding of radiolabeled monoclonal antifibrin antibody 59D8 (specific for fibrin but not fibrinogen) to a series of degraded fibrin clots showed that the availability of the B beta(15-21) epitope (against which 59D8 had been raised) was inversely proportional to the extent of clot lysis. Examination of digest supernatants revealed that the B beta(15-21) epitope was released from clots as a high molecular weight degradation product in the presence of calcium ions but that the generation of low molecular weight peptides occurred in the absence of calcium ions. To address the question of epitope accessibility, we compared levels of fibrin clot binding among four radioactively labeled antibodies: antifibrin monoclonal antibody 59D8, two antifibrinogen monoclonal antibodies that cross-reacted with fibrin, and an affinity-purified polyclonal antifibrinogen antibody. We expected that the antifibrinogen antibodies would show enhanced binding to clots in comparison with the antifibrin antibody. However, the epitope accessibility experiments showed that all four antibody preparations bound fibrin clots at comparable levels. Taken together, these studies demonstrated that one fibrin-specific epitope, B beta(15-21), remains available on clots as they undergo degradation by plasmin and, importantly, that the epitope is not solubilized at a rate faster than the rate at which the clot is itself solubilized. The availability of the B beta(15-21) epitope during the course of plasminolysis assures the potential utility of antifibrin antibodies such as 59D8 for detecting thrombi and targeting plasminogen activators.

  4. Successful Endoscopic Management of Non-Healing Perforated Duodenal Ulcer with Polyglycolic Acid Sheet and Fibrin Glue.

    Science.gov (United States)

    Mishiro, Tsuyoshi; Shibagaki, Kotaro; Matsuda, Kayo; Fukuyama, Chika; Okada, Mayumi; Mikami, Hironobu; Izumi, Daisuke; Yamashita, Noritsugu; Okimoto, Eiko; Fukuda, Naoki; Aimi, Masahito; Fukuba, Nobuhiko; Oshima, Naoki; Takanashi, Toshihiro; Matsubara, Takeshi; Ishimura, Norihisa; Ishihara, Shunji; Kinoshita, Yoshikazu

    2016-08-01

    In recent years, treatment techniques in which polyglycolic acid sheets are applied to various situations with fibrin glue have exhibited great clinical potential, and previous studies have reported safety and efficacy. We describe closure of a non-healing perforated duodenal ulcer with the use of a polyglycolic acid sheet and fibrin glue in an elderly patient who was not a candidate for surgery.

  5. The use of fibrin and poly(lactic-co-glycolic acid hybrid scaffold for articular cartilage tissue engineering: an in vivo analysis

    Directory of Open Access Journals (Sweden)

    S Munirah

    2008-02-01

    Full Text Available Our preliminary results indicated that fibrin and poly(lactic-co-glycolic acid (PLGA hybrid scaffold promoted early chondrogenesis of articular cartilage constructs in vitro. The aim of this study was to evaluate in vivo cartilaginous tissue formation by chondrocyte-seeded fibrin/PLGA hybrid scaffolds. PLGA scaffolds were soaked carefully, in chondrocyte-fibrin suspension, and polymerized by dropping thrombin-calcium chloride (CaCl2 solution. PLGA-seeded chondrocytes were used as a control. Resulting constructs were implanted subcutaneously, at the dorsum of nude mice, for 4 weeks. Macroscopic observation, histological evaluation, gene expression and sulphated-glycosaminoglycan (sGAG analyses were performed at each time point of 1, 2 and 4 weeks post-implantation. Cartilaginous tissue formation in fibrin/PLGA hybrid construct was confirmed by the presence of lacunae and cartilage-isolated cells embedded within basophilic ground substance. Presence of proteoglycan and glycosaminoglycan (GAG in fibrin/PLGA hybrid constructs was confirmed by positive Safranin O and Alcian Blue staining. Collagen type II exhibited intense immunopositivity at the pericellular matrices. Chondrogenic properties were further demonstrated by the expression of gene encoded cartilage-specific markers, collagen type II and aggrecan core protein. The sGAG production in fibrin/PLGA hybrid constructs was higher than in the PLGA group. In conclusion, fibrin/PLGA hybrid scaffold promotes cartilaginous tissue formation in vivo and may serve as a potential cell delivery vehicle and a structural basis for articular cartilage tissue-engineering.

  6. Long-Standing Motor and Sensory Recovery following Acute Fibrin Sealant Based Neonatal Sciatic Nerve Repair

    Directory of Open Access Journals (Sweden)

    Natalia Perussi Biscola

    2016-01-01

    Full Text Available Brachial plexus lesion results in loss of motor and sensory function, being more harmful in the neonate. Therefore, this study evaluated neuroprotection and regeneration after neonatal peripheral nerve coaptation with fibrin sealant. Thus, P2 neonatal Lewis rats were divided into three groups: AX: sciatic nerve axotomy (SNA without treatment; AX+FS: SNA followed by end-to-end coaptation with fibrin sealant derived from snake venom; AX+CFS: SNA followed by end-to-end coaptation with commercial fibrin sealant. Results were analyzed 4, 8, and 12 weeks after lesion. Astrogliosis, microglial reaction, and synapse preservation were evaluated by immunohistochemistry. Neuronal survival, axonal regeneration, and ultrastructural changes at ventral spinal cord were also investigated. Sensory-motor recovery was behaviorally studied. Coaptation preserved synaptic covering on lesioned motoneurons and led to neuronal survival. Reactive gliosis and microglial reaction decreased in the same groups (AX+FS, AX+CFS at 4 weeks. Regarding axonal regeneration, coaptation allowed recovery of greater number of myelinated fibers, with improved morphometric parameters. Preservation of inhibitory synaptic terminals was accompanied by significant improvement in the motor as well as in the nociceptive recovery. Overall, the present data suggest that acute repair of neonatal peripheral nerves with fibrin sealant results in neuroprotection and regeneration of motor and sensory axons.

  7. Growth factor and proteinase profile of Vivostat® platelet-rich fibrin linked to tissue repair.

    Science.gov (United States)

    Agren, M S; Rasmussen, K; Pakkenberg, B; Jørgensen, B

    2014-07-01

    Autologous platelet-rich fibrin (PRF(®)) is prepared by the automatic Vivostat(®) system. Conflicting results with Vivostat PRF in acute wound healing prompted us to examine its cellular and biomolecular composition. Specifically, platelets, selected growth factors and matrix metalloproteinase (MMP)-9 were quantified using novel analytical methods. Ten healthy non-thrombocytopenic volunteers donated blood for generation of intermediate fibrin-I and final PRF. Anticoagulated whole blood and serum procured in parallel served as baseline controls. Leucocyte, erythrocyte and platelet counts in whole blood and fibrin-I were determined by automated haematology analyser. Platelet concentration in PRF was quantified manually by stereologic analysis of Giemsa-stained tissue sections, and the total content of five growth factors and MMP-9 by enzyme-linked immunosorbent assays. The number of leucocytes and erythrocytes was reduced (P platelets increased (P fibrin-I versus whole blood. PRF contained 982 ± 206 × 10(9) platelets/l representing 3·9-fold (P platelet-derived growth factor (PDGF)-AB [2·5-fold, P PDGF-BB [1·6-fold, P vascular endothelial growth factor > basic fibroblast growth factor [75-fold, P platelet enrichment and biomolecular constituents may guide clinicians in their optimal use of Vivostat PRF for tissue regenerative applications. © 2013 International Society of Blood Transfusion.

  8. Protein nanocoatings on synthetic polymeric nanofibrous membranes designed as carriers for skin cells.

    Science.gov (United States)

    Bacakova, Marketa; Pajorova, Julia; Stranska, Denisa; Hadraba, Daniel; Lopot, Frantisek; Riedel, Tomas; Brynda, Eduard; Zaloudkova, Margit; Bacakova, Lucie

    2017-01-01

    Protein-coated resorbable synthetic polymeric nanofibrous membranes are promising for the fabrication of advanced skin substitutes. We fabricated electrospun polylactic acid and poly(lactide- co -glycolic acid) nanofibrous membranes and coated them with fibrin or collagen I. Fibronectin was attached to a fibrin or collagen nanocoating, in order further to enhance the cell adhesion and spreading. Fibrin regularly formed a coating around individual nanofibers in the membranes, and also formed a thin noncontinuous nanofibrous mesh on top of the membranes. Collagen also coated most of the fibers of the membrane and randomly created a soft gel on the membrane surface. Fibronectin predominantly adsorbed onto a thin fibrin mesh or a collagen gel, and formed a thin nanofibrous structure. Fibrin nanocoating greatly improved the attachment, spreading, and proliferation of human dermal fibroblasts, whereas collagen nanocoating had a positive influence on the behavior of human HaCaT keratinocytes. In addition, fibrin stimulated the fibroblasts to synthesize fibronectin and to deposit it as an extracellular matrix. Fibrin coating also showed a tendency to improve the ultimate tensile strength of the nanofibrous membranes. Fibronectin attached to fibrin or to a collagen coating further enhanced the adhesion, spreading, and proliferation of both cell types.

  9. In-vitro-Studie zum Einfluss von Fibrin in Knorpelkonstrukten auf der Basis von PGA-Vliesstoffen

    DEFF Research Database (Denmark)

    Schmal, H; Mehlhorn, A T; Kurze, C

    2008-01-01

    BACKGROUND: The matrix component in autologous chondrocyte implantation plays an important role. In this study the influence of an additional fibrin component in cartilage constructs based on polyglycolide polymers (PGA) was investigated. METHODS: Human chondrocytes of femoral heads were isolated....... CONCLUSION: Cartilage constructs based on carbohydrate matrices are suitable for matrix-associated chondrocyte implantation. The results of this study suggest a partially inhibitory effect of an additional fibrin component in PGA constructs for chondrogenic differentiation....

  10. The fast release of stem cells from alginate-fibrin microbeads in injectable scaffolds for bone tissue engineering

    Science.gov (United States)

    Zhou, Hongzhi; Xu, Hockin H. K.

    2011-01-01

    Stem cell-encapsulating hydrogel microbeads of several hundred microns in size suitable for injection, that could quickly degrade to release the cells, are currently unavailable. The objectives of this study were to: (1) develop oxidized alginate-fibrin microbeads encapsulating human umbilical cord mesenchymal stem cells (hUCMSCs); (2) investigate microbead degradation, cell release, and osteogenic differentiation of the released cells for the first time. Three types of microbeads were fabricated to encapsulate hUCMSCs: (1) Alginate microbeads; (2) oxidized alginate microbeads; (3) oxidized alginate-fibrin microbeads. Microbeads with sizes of about 100–500 µm were fabricated with 1×106 hUCMSCs/mL of alginate. For the alginate group, there was little microbead degradation, with very few cells released at 21 d. For oxidized alginate, the microbeads started to slightly degrade at 14 d. In contrast, the oxidized alginate-fibrin microbeads started to degrade at 4 d and released the cells. At 7 d, the number of released cells greatly increased and showed a healthy polygonal morphology. At 21 d, the oxidized alginate-fibrin group had a live cell density that was 4-fold that of the oxidized alginate group, and 15-fold that of the alginate group. The released cells had osteodifferentiation, exhibiting highly elevated bone marker gene expressions of ALP, OC, collagen I, and Runx2. Alizarin staining confirmed the synthesis of bone minerals by hUCMSCs, with the mineral concentration at 21 d being 10-fold that at 7 d. In conclusion, fast-degradable alginate-fibrin microbeads with hUCMSC encapsulation were developed that could start to degrade and release the cells at 4 d. The released hUCMSCs had excellent proliferation, osteodifferentiation, and bone mineral synthesis. The alginate-fibrin microbeads are promising to deliver stem cells inside injectable scaffolds to promote tissue regeneration. PMID:21757229

  11. Crosslinking of fihrinogen by factor XIHa exposes fibrin-specific epitopes and induces enhanced plasminogen activation by t-PA

    NARCIS (Netherlands)

    Nieuwenhuizen, W.; Voskuilen, M.; Kevin, R.; Siebenlis; Michael, W.; Mosesson

    1996-01-01

    'Fibrin-specific'epitopes 'Aαl48-160' and 'γ312-324' are exposed when fibrinogen (Fbg) is converted to fibrin (Fb). Particularly, polymerized Fb enhances the t-PA-mediated plasminogen activation. Fb polymerization involves 'D:E' assembly, end-to-end self-association ('D:D') and interactions between

  12. Scintigraphic evaluation of osteoblastic activity in extraction sockets treated with platelet-rich fibrin.

    Science.gov (United States)

    Gürbüzer, Bahadir; Pikdöken, Levent; Tunali, Mustafa; Urhan, Muammer; Küçükodaci, Zafer; Ercan, Feriha

    2010-05-01

    To evaluate the effect of platelet-rich fibrin (PRF) on the early bone healing process with bone scintigraphy based on technetium-99m methylene diphosphonate uptake in third molar extraction sockets. Fourteen patients with bilaterally soft tissue impacted third mandibular molars were included in the study. The right and left impacted third molars were surgically extracted in the same session. PRF was randomly administered into one of the extraction sockets, whereas the contralateral sockets were left without treatment. Four weeks after surgery, scintigrams were obtained to evaluate scintigraphic differences between PRF-treated and non-PRF-treated sockets. After completion of the clinical study, PRF samples were evaluated by light and scanning electron microscopy. The average increase in technetium-99m methylene diphosphonate uptake as an indication of enhanced bone healing did not differ significantly between PRF-treated and non-PRF-treated sockets 4 weeks postoperatively (P > .05). Abundant fibrin and inflammatory cells were observed by light microscopic examination of PRF samples. Scanning electron microscopic analysis of PRF revealed the existence of platelet aggregates in a fibrin network and crystalline particles on the outer surface of PRF. PRF might not lead to enhanced bone healing in soft tissue impacted mandibular third molar extraction sockets 4 weeks after surgery. PRF exhibits the potential characteristics of an autologous fibrin matrix. However, whether the presence of crystal-like particles on the outer surface of PRF alters bone healing should be investigated further. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Comparing different preparation methods to study human fibrin fibers and platelets using TEM.

    Science.gov (United States)

    Buys, Antoinette V; Pretorius, Etheresia

    2012-06-01

    For the study of cellular ultrastructure, the sample needs to be stabilized by fixation, with the ultimate aim to preserve the native tissue organization and to protect the tissue against later stages of preparation. Chemical and freezing fixation are most used, and chemical fixation employs agents that permeate tissues and cells by diffusion and covalently bind with their major biochemical constituents to fix them. Most widely used chemical fixatives are aldehydes, e.g., formaldehyde and glutaraldehyde, which are noncoagulating, crosslinking agents. Cryofixation methods for ultrastructural studies are also popular, and high-pressure freezing immobilizes all cell constituents and arrests biological activity by removing the thermal energy from the system. In the current research, we used platelet-rich plasma (PRP) to study expansive fibrin fibers and platelet ultrastructure to compare the two fixation techniques. We also used thrombin and calcium chloride as a clotting agent to determine the technique most suitable for the formation of extensive fibrin networks. Chemically fixated fibrin fibers were more compact and condensed and also showed a banding pattern on longitudinal sections. High-pressure frozen samples were more dispersed while platelets fixated showed better preserved cellular membranes and organelle structure. PRP coagulated by addition of CaCl(2) showed blood platelets that are noticeably more activated compared with PRP; however, with thrombin, a sharp ultrastructure was seen. We conclude that PRP mixed with thrombin, and freeze substituted, is the most suitable method for the study of extensive fibrin fibers as well as platelets. Copyright © 2011 Wiley Periodicals, Inc.

  14. CT-guided percutaneous injection of the fibrin glue by 'double needle' technique for the treatment of sacral cysts

    International Nuclear Information System (INIS)

    Wang Ganggang; Chen Long; Yang Chao; Ni Caifang

    2013-01-01

    Objective: To analyze the efficacy and safety of CT-guided percutaneous injection of the fibrin glue by 'double needle' technique to treat sacral cyst. Methods: Clinical data of 20 cases with 'double-needle' injection of fibrin glue technology to treat sacral cyst were retrospectively analyzed. All patients had varying degrees of sacral nerve root compression symptoms. The treatment for sacral cyst was carried out after clear diagnosis was made. On the basis of CT-guided percutaneous injection of fibrin glue, the improved CT-guided percutaneous injection of fibrin glue by 'double-needle' technique was used to treat these patients. The average dose of fibrin glue was (5.9 ± 2.4) ml. The clinical results of improvement as to pain and neurological function were evaluated after follow-up of an average of 17 months. The assessment criteria were as follows: excellent, complete resolution of signs and symptoms, with the patient returning to his or her regular employment and no recurrence of cysts during 1 year of follow-up, good, symptoms and signs in the legs and perineal region resolved but with persistent pain in the lumbosacral region, which did not interfere with the patient's regular work (the cysts did not recur for 6 months during follow-up), fair, no improvement in clinical symptoms, but a decrease in cyst size on the imaging study, poor, no improvement in clinical symptoms and no observed changes in cyst size in imaging studies or recurrence. Results: Most patients experienced some degree of pain relief and functional improvement after fibrin glue therapy, with most experiencing complete or marked resolution of clinical symptoms. Nine patients reported excellent recovery, 8 reported good recovery, 2 reported fair recovery, and 1 reported poor recovery. The overall percentage of positive outcomes (excellent and good recovery) was 85%. No serious postoperative complications were discovered. Conclusions: CT guided percutaneous injection of the fibrin glue by

  15. Calibration of pulsed field gel electrophoresis for measurement of DNA double-strand breaks

    International Nuclear Information System (INIS)

    Ager, D.D.; Dewey, W.C.

    1990-01-01

    Pulsed field gel electrophoresis (PFGE) assay was calibrated for the measurement of X-ray induced DNA double-strand breaks in Chinese hamster ovary (CHO) cells. Calibration was conducted by incorporating [ 125 I] deoxyuridine into DNA, which induces one double-strand break for every disintegration that occurs in frozen cells. Based on the percentage of DNA migrating into the gel, the number of breaks/dalton/Gy was estimated to be (9.3±1.0) x 10 -12 . This value is close to (10 to 12) x 10 -12 determined by neutral filter elution using similar cell lysis procedures at 24 o C and at pH8.0. The estimate is in good agreement with the value of (11.7±2) x 10 -12 breaks/dalton/Gy as measured in Ehrlich ascites tumour cells using the neutral sucrose gradient method (Bloecher 1988), and (6 to 9) x 10 -12 breaks/dalton/Gy as measured in mouse L and Chinese hamster V79 cells using neutral filter elution (Radford and Hodgson 1985). (author)

  16. Physical Properties of Silicone Gel Breast Implants.

    Science.gov (United States)

    Jewell, Mark L; Bengtson, Bradley P; Smither, Kate; Nuti, Gina; Perry, TracyAnn

    2018-04-28

    Surgical applications using breast implants are individualized operations to fill and shape the breast. Physical properties beyond shape, size, and surface texture are important considerations during implant selection. Compare form stability, gel material properties, and shell thickness of textured shaped, textured round, and smooth round breast implants from 4 manufacturers: Allergan, Mentor, Sientra, and Establishment Labs through bench testing. Using a mandrel height gauge, form stability was measured by retention of dimensions on device movement from a horizontal to vertical supported orientation. Dynamic response of gel material (gel cohesivity, resistance to gel deformation, energy absorption) was measured using a synchronized target laser following application of graded negative pressure. Shell thickness was measured using digital thickness gauge calipers. Form stability, gel material properties, and shell thickness differed across breast implants. Of textured shaped devices, Allergan Natrelle 410 exhibited greater form stability than Mentor MemoryShape and Sientra Shaped implants. Allergan Inspira round implants containing TruForm 3 gel had greater form stability, higher gel cohesivity, greater resistance to gel deformation, and lower energy absorption than those containing TruForm 2 gel and in turn, implants containing TruForm 1 gel. Shell thickness was greater for textured versus smooth devices, and differed across styles. Gel cohesivity, resistance to gel deformation, and energy absorption are directly related to form stability, which in turn determines shape retention. These characteristics provide information to aid surgeons choosing an implant based on surgical application, patient tissue characteristics, and desired outcome.

  17. Detection of von Willebrand factor and tissue factor in platelets-fibrin rich coronary thrombi in acute myocardial infarction.

    Science.gov (United States)

    Yamashita, Atsushi; Sumi, Takahiro; Goto, Shinya; Hoshiba, Yasunari; Nishihira, Kensaku; Kawamoto, Riichirou; Hatakeyama, Kinta; Date, Haruhiko; Imamura, Takuroh; Ogawa, Hisao; Asada, Yujiro

    2006-01-01

    The rapid closure of coronary arteries due to occlusive thrombi is the major cause of acute myocardial infarction. However, the mechanisms of coronary thrombus formation have not been elucidated. We immunohistochemically assessed the localizations and their changes over time of glycoprotein IIb/IIIa, fibrin, von Willebrand factor (vWF), and tissue factor (TF), after the onset of chest pain (platelets, fibrin, vWF, and TF from the early phase of onset, and glycoprotein IIb/IIIa and fibrin were closely associated with vWF and TF, respectively. vWF and/or TF may contribute to occlusive thrombus formation and be novel therapeutic candidates for treating patients with coronary thrombosis.

  18. Clinical experience of intrapleural administration of fibrin glue for secondary pneumothorax with advanced lung cancer

    International Nuclear Information System (INIS)

    Nishino, Takeshi; Takizawa, Hiromitsu; Yoshida, Mitsuteru; Kawakami, Yukikiyo; Sakiyama, Shoji; Kondo, Kazuya

    2014-01-01

    Secondary pneumothorax with advanced lung cancer is an intractable and serious pathosis, which directly aggravates patients' Quality of Life (QOL) and prognosis. We first select the intrapleural administration of fibrin glue for secondary pneumothorax with advanced lung cancer. From April 2009 to May 2012, we encountered 5 patients who developed secondary pneumothorax during treatment for advanced lung cancer. Their average age was 60.8 years old, and 4 of them had squamous cell carcinoma, 1 had adenocarcinoma, and all had unresectable advanced lung cancer. In 4 of them, the point of air leakage could be detected by pleurography, and leakage could be stopped by the intrapleural administration of fibrin glue. All of them could receive chemotherapy or radiotherapy after treatment for secondary pneumothorax. The intrapleural administration of fibrin glue may be an effective and valid treatment for intractable secondary pneumothorax with advanced lung cancer. (author)

  19. Manufacturing of different gel detectors and their calibration for spatial radiation dose measurements

    International Nuclear Information System (INIS)

    Bero, M.

    2008-05-01

    Three types of gel dosemeter have been made and their most important properties for radiation dosimetry were studied. The comparison between the three categories helps to widen knowledge in each of these detectors and to establish a method for the preparation as well as testing of this radiation sensitive materials. Experiments show the technical application possibility for using these gel detectors to measure the spatial radiation dose distribution in the range of doses given for cancer treatment. The experimental results give some important characteristic for the three gel dosemeter used in comparison to that of the traditional dosimetry systems. It also shows the simplicity of manufacturing the dosemeter from low cost materials and its radiation response to ionizing. The relationships between the dosemeter response and the dose rate as well as the radiation energy were also investigated. Important subjects that have been also taken into consideration are the effects of ambient conditions and storage likelihood of the studied materials. Recommendation was made for the use of these materials in practical applications and for handling as well as their long term storage possibility. (author)

  20. Microfluidic production of bioactive fibrin micro-beads embedded in crosslinked collagen used as an injectable bulking agent for urinary incontinence treatment.

    Science.gov (United States)

    Vardar, E; Larsson, H M; Allazetta, S; Engelhardt, E M; Pinnagoda, K; Vythilingam, G; Hubbell, J A; Lutolf, M P; Frey, P

    2018-02-01

    Endoscopic injection of bulking agents has been widely used to treat urinary incontinence, often due to urethral sphincter complex insufficiency. The aim of the study was to develop a novel injectable bioactive collagen-fibrin bulking agent restoring long-term continence by functional muscle tissue regeneration. Fibrin micro-beads were engineered using a droplet microfluidic system. They had an average diameter of 140 μm and recombinant fibrin-binding insulin-like growth factor-1 (α 2 PI 1-8 -MMP-IGF-1) was covalently conjugated to the beads. A plasmin fibrin degradation assay showed that 72.5% of the initial amount of α 2 PI 1-8 -MMP-IGF-1 loaded into the micro-beads was retained within the fibrin micro-beads. In vitro, the growth factor modified fibrin micro-beads enhanced cell attachment and the migration of human urinary tract smooth muscle cells, however, no change of the cellular metabolic activity was seen. These bioactive micro-beads were mixed with genipin-crosslinked homogenized collagen, acting as a carrier. The collagen concentration, the degree of crosslinking, and the mechanical behavior of this bioactive collagen-fibrin injectable were comparable to reference samples. This novel injectable showed no burst release of the growth factor, had a positive effect on cell behavior and may therefore induce smooth muscle regeneration in vivo, necessary for the functional treatment of stress and other urinary incontinences. Urinary incontinence is involuntary urine leakage, resulting from a deficient function of the sphincter muscle complex. Yet there is no functional cure for this devastating condition using current treatment options. Applied physical and surgical therapies have limited success. In this study, a novel bioactive injectable bulking agent, triggering new muscle regeneration at the injection site, has been evaluated. This injectable consists of cross-linked collagen and fibrin micro-beads, functionalized with bound insulin-like growth factor

  1. Staple line reinforcement with fleece-coated fibrin glue (TachoComb) after thoracoscopic bullectomy for the treatment of spontaneous pneumothorax

    International Nuclear Information System (INIS)

    Muramatsu, Takashi; Ohmori, Kazumitsu; Shimamura, Mie; Furuichi, Motohiko; Takeshita, Shinji; Negishi, Nanao

    2007-01-01

    We investigated the cause of pneumothorax recurrence after thoracoscopic surgery and the effectiveness of staple line reinforcement with fleece-coated fibrin glue (TachoComb) in the prevention of postoperative pneumothorax recurrence. From April 3, 1992 to the end of December 2005, thoracoscopic bullectomy was performed on 499 patients of primary spontaneous pneumothorax. The causes of recurrence were investigated on 39 patients on the basis of surgical observations, preoperative chest computed tomography, and so on. The most common cause was new bulla formation (37 cases), 19 of which were apparently related to the staple line (within 1 cm of the staple lines) and 15 of which were not related to the staple line. After 2000, we stopped using forceps to grasp lungs and we have reinforced the staple line by applying fleece-coated fibrin glue. The staple line reinforced with fleece-coated fibrin glue, or sprayed with fibrin glue solution and the untreated group (bullectomy only with staples) were compared, and the recurrence rates were 1.22%, 7.25%, and 10.00%, respectively (P=0.0006021). The recurrence rate after thoracoscopic bullectomy with fleece-coated fibrin glue was significantly lowered and we consider this procedure to be the treatment of choice for the management of spontaneous pneumothorax. (author)

  2. IMMEDIATE AND DISTANT EFFECTS OF THE PANCREATIC DUCT OCCLUSION BY THE FIBRIN ADHESIVE

    Directory of Open Access Journals (Sweden)

    Vojin Savić

    2002-05-01

    Full Text Available The paper represent an experimental study whose aim was to determine immediate consequences of the pancreatic duct occlusion by the fibrin adhesive upon the pancreas parenchyma as well as distant negative effects upon the exocrine and endocrine pancreatic secretion.The experiment was carried out on the dogs divided into two groups of twenty animals, namely, into the experimental group of those animals that were subdued to the pancreas resection with the PJA formation and the anastomosis protection by means of the pancreatic duct occlusion with the fibrin adhesive (Tissucol - Immuno AG and the control group that was, under the same conditions, subdued to the pancreas resection and the PJA with no anastomosis protection. In the post-operative course the animals cere monitored for five months and during that time they were subjected to the clinic, biochemical, pathohistological, histochemical, immunocito-chemical and scanning electronic-microscopic examination.The fibrin cork lyse was noticed since the fifth post-operative day while it was fully completed on the thirteenth post-operative day. The statistical analysis of the biochemical parameters as well as pathohistological and scanning-electronic exami-nations have revealed the signs of easier, sub-clinic forms of edematose pancreatitis with a short-term increase of the amylase level. The examinations after 150 days have shown the preserved morphology and the functional integrity of the exocrine and en-docrine pancreas.The authors conclude that the fibrin adhesive application in preventing the loosening up of the pancreatic jejuna anastomosis represents a simple and efficient procedure with no negative effects upon the exocrine and endocrine function and the pancreas morphology.

  3. Clinical observation on fibrin glue technique in pterygium surgery performed with limbal autograft transplantation

    Directory of Open Access Journals (Sweden)

    Hui Liu

    2013-07-01

    Full Text Available AIM: To compare the efficiency and safety of fibrin glue to suture technique in pterygium surgery performed with limbal autograft.METHODS: A prospective randomized clinical trial was carried out in 60 eyes of 48 patients operated for primary nasal pterygium. Autologous limbal graft taken from the superotemporal limbus was used to cover the sclera after pterygium excision under local anesthesia with 2% lidocaine. In 22 cases(30 eyes, the transplant was attached to the sclera with a fibrin tissue adhesive(group 1and in 26 cases(30 eyeswith 10-0 Virgin silk sutures(group 2. Patients were followed up at least for 3 months. Time of operation, matching degree of graft and visual analogue scale(VASscore were mainly observed and recorded. RESULTS: Patient symptoms were significantly less and biomicroscopic findings were better in group 1. Pterygium recurrence was seen in 1 case of group 1, and 1 case of group 2. Average surgery time was shorter(PCONCLUSION: Using fibrin glue for graft fixation in pterygium surgery causes significantly less postoperative pain and shortens surgery time significantly.

  4. Product-selective blot: a technique for measuring enzyme activities in large numbers of samples and in native electrophoresis gels

    International Nuclear Information System (INIS)

    Thompson, G.A.; Davies, H.M.; McDonald, N.

    1985-01-01

    A method termed product-selective blotting has been developed for screening large numbers of samples for enzyme activity. The technique is particularly well suited to detection of enzymes in native electrophoresis gels. The principle of the method was demonstrated by blotting samples from glutaminase or glutamate synthase reactions into an agarose gel embedded with ion-exchange resin under conditions favoring binding of product (glutamate) over substrates and other substances in the reaction mixture. After washes to remove these unbound substances, the product was measured using either fluorometric staining or radiometric techniques. Glutaminase activity in native electrophoresis gels was visualized by a related procedure in which substrates and products from reactions run in the electrophoresis gel were blotted directly into a resin-containing image gel. Considering the selective-binding materials available for use in the image gel, along with the possible detection systems, this method has potentially broad application

  5. Platelet Counts in Insoluble Platelet-Rich Fibrin Clots: A Direct Method for Accurate Determination

    Directory of Open Access Journals (Sweden)

    Yutaka Kitamura

    2018-02-01

    Full Text Available Platelet-rich fibrin (PRF clots have been used in regenerative dentistry most often, with the assumption that growth factor levels are concentrated in proportion to the platelet concentration. Platelet counts in PRF are generally determined indirectly by platelet counting in other liquid fractions. This study shows a method for direct estimation of platelet counts in PRF. To validate this method by determination of the recovery rate, whole-blood samples were obtained with an anticoagulant from healthy donors, and platelet-rich plasma (PRP fractions were clotted with CaCl2 by centrifugation and digested with tissue-plasminogen activator. Platelet counts were estimated before clotting and after digestion using an automatic hemocytometer. The method was then tested on PRF clots. The quality of platelets was examined by scanning electron microscopy and flow cytometry. In PRP-derived fibrin matrices, the recovery rate of platelets and white blood cells was 91.6 and 74.6%, respectively, after 24 h of digestion. In PRF clots associated with small and large red thrombi, platelet counts were 92.6 and 67.2% of the respective total platelet counts. These findings suggest that our direct method is sufficient for estimating the number of platelets trapped in an insoluble fibrin matrix and for determining that platelets are distributed in PRF clots and red thrombi roughly in proportion to their individual volumes. Therefore, we propose this direct digestion method for more accurate estimation of platelet counts in most types of platelet-enriched fibrin matrix.

  6. Three dimensional measurements of absorbed dose in BNCT by Fricke-gel imaging

    International Nuclear Information System (INIS)

    Gambarini, G.; Agosteo, S.; Marchesi, P.; Nava, E.; Palazzi, P.; Pecci, A.; Rosa, R.; Rosi, G.; Tinti, R.

    2001-01-01

    A method has been studied for absorbed dose imaging and profiling in a phantom exposed to thermal or epithermal neutron fields, also discriminating between various contributions to the absorbed dose. The proposed technique is based on optical imaging of FriXy-gel phantoms, which are proper tissue-equivalent phantoms acting as continuous dosimeters. Convenient modifications in phantom composition allow, from differential measurements, the discrimination of various contributions to the absorbed dose. The dosimetry technique is based on a chemical dosimeter incorporated in a tissue-equivalent gel (Agarose). The chemical dosimeter is a ferrous sulphate solution (which is the main component of the standard Fricke dosimeter) added with a metal ion indicator (Xylenol Orange). The absorbed dose is measured by analysing the variation of gel optical absorption in the visible spectrum, imaged by means of a CCD camera provided with a suitable filter. The technique validity has been tested by irradiating and analysing phantoms in the thermal facility of the fast research reactor TAPIRO (ENEA, Casaccia, Italy). In a cylindrical phantom simulating a head, we have imaged the therapy dose from thermal neutron reactions with 10 B and the dose in healthy tissue not containing boron. In tissue without boron, we have discriminated between the two main contributions to the absorbed dose, which comes from the 1 H(n,γ) 2 H and 14 N(n,p) 14 C reactions. The comparison with the results of other experimental techniques and of simulations reveals that the technique is very promising. A method for the discrimination of fast neutron contribution to the absorbed dose, still in an experimental stage, is proposed too. (author)

  7. Gallium67 scintigraphy in fibrinous pericarditis associated with bacterial endocarditis

    International Nuclear Information System (INIS)

    Martin, P.; Verhas, M.; Devriendt, J.; Goffin, Y.

    1982-01-01

    An 80-year-old man presented with pyrexia, progressive cardiac failure and inflammation. A diagnosis of pericarditisd associated with bacterial endocarditis was suggested from Gallium 67 scintigraphy and confirmed at autpsy. This case of fibrinous pericarditis without effusion could not be diagnosed by echography or routine cardiopulmonary scintigraphy. (orig.)

  8. Development of methods to measure hemoglobin adducts by gel electrophoresis - Preliminary results

    International Nuclear Information System (INIS)

    Sun, J.D.; McBride, S.M.

    1988-01-01

    Chemical adducts formed on blood hemoglobin may be a useful biomarker for assessing human exposures to these compounds. This paper reports preliminary results in the development of methods to measure such adducts that may be generally applicable for a wide variety of chemicals. Male F344/N rats were intraperitoneally injected with 14 C-BaP dissolved in corn oil. Twenty-four hours later, the rats were sacrificed. Blood samples were collected and globin was isolated. Globin protein was then cleaved into peptide fragments using cyanogen bromide and the fragments separated using 2-dimensional gel electrophoresis. The results showed that the adducted 14 C-globin fragments migrated to different areas of the gel than did unadducted fragments. Further research is being conducted to develop methods that will allow quantitation of separated adducted globin fragments from human blood samples without the use of a radiolabel. (author)

  9. Advanced platelet-rich fibrin: a new concept for cell-based tissue engineering by means of inflammatory cells.

    Science.gov (United States)

    Ghanaati, Shahram; Booms, Patrick; Orlowska, Anna; Kubesch, Alica; Lorenz, Jonas; Rutkowski, Jim; Landes, Constantin; Sader, Robert; Kirkpatrick, Cj; Choukroun, Joseph

    2014-12-01

    Choukroun's platelet-rich fibrin (PRF) is obtained from blood without adding anticoagulants. In this study, protocols for standard platelet-rich fibrin (S-PRF) (2700 rpm, 12 minutes) and advanced platelet-rich fibrin (A-PRF) (1500 rpm, 14 minutes) were compared to establish by histological cell detection and histomorphometrical measurement of cell distribution the effects of the centrifugal force (speed and time) on the distribution of cells relevant for wound healing and tissue regeneration. Immunohistochemistry for monocytes, T and B -lymphocytes, neutrophilic granulocytes, CD34-positive stem cells, and platelets was performed on clots produced from four different human donors. Platelets were detected throughout the clot in both groups, although in the A-PRF group, more platelets were found in the distal part, away from the buffy coat (BC). T- and B-lymphocytes, stem cells, and monocytes were detected in the surroundings of the BC in both groups. Decreasing the rpm while increasing the centrifugation time in the A-PRF group gave an enhanced presence of neutrophilic granulocytes in the distal part of the clot. In the S-PRF group, neutrophils were found mostly at the red blood cell (RBC)-BC interface. Neutrophilic granulocytes contribute to monocyte differentiation into macrophages. Accordingly, a higher presence of these cells might be able to influence the differentiation of host macrophages and macrophages within the clot after implantation. Thus, A-PRF might influence bone and soft tissue regeneration, especially through the presence of monocytes/macrophages and their growth factors. The relevance and feasibility of this tissue-engineering concept have to be proven through in vivo studies.

  10. Elevated NT-proBNP is associated with unfavorably altered plasma fibrin clot properties in atrial fibrillation.

    Science.gov (United States)

    Matusik, Paweł T; Matusik, Patrycja S; Kornacewicz-Jach, Zdzisława; Małecka, Barbara; Ząbek, Andrzej; Undas, Anetta

    2017-09-15

    Dense fibrin clot formation and hypofibrinolysis have been reported in atrial fibrillation (AF). It is unclear which factors affect fibrin clot properties in AF. We investigated plasma fibrin clot permeability (K s ), clot lysis time (CLT), endogenous thrombin potential (ETP) as well as other coagulation and fibrinolysis parameters along with N-terminal pro-B-type natriuretic peptide (NT-proBNP) in 160 AF patients (median age, 70.5years). Previous stroke (n=15; 9.4%) was associated with decreased K s (P=0.04) and longer CLT (P=0.005), together with higher antiplasmin (P=0.03) and lower tissue-type plasminogen activator (P=0.01). Lower K s (P=0.04) and tendency towards longer CLT (P=0.10) were observed in patients with a left atrium diameter>40mm. Patients with a CHA 2 DS 2 -VASc score of 3 or more (82.5%) were characterized by higher thrombin-activatable fibrinolysis inhibitor antigen (P=0.009). K s was inversely correlated with log NT-proBNP (r=-0.34, PCLT was positively correlated with log NT-proBNP (R=0.61, PCLT (the top quartile,≥109min). In AF patients prothrombotic fibrin clot properties assessed ex vivo are determined by PAI-1 and NT-proBNP and this phenotype is associated with prior ischemic stroke. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Positron annihilation lifetime studies of sol-gel transition of carrageenan gels

    International Nuclear Information System (INIS)

    Wakabayashi, Y.; Ito, K.; Li, H.L.; Ujihara, Y.

    1996-01-01

    Positron annihilation lifetime measurement was applied to study the sol-gel transition of anionic polysaccharide aqueous solutions in terms of free-volume parameters the size, intensity, and size distribution of free volumes of the gelation of K-form κ-carrageenan solutions as a function of temperature. Slight variations of free volume size and intensity against temperature were observed near 295 K. The correlation of free-volume data with other physical properties vibrational spectra (IR and Raman), conductivity, SAXS, elastic measurement, differential scanning calorimetry were investigated to understand the mechanism of sol-gel transition of carrageenan. (author)

  12. Use of fibrin glue in the management of recurrent pterygium by conjunctival autograft

    International Nuclear Information System (INIS)

    Virendra K. Malik; Sandeep Kumar

    2010-01-01

    To evaluate whether use of fibrin glue instead of sutures for the treatment of recurrent pterygium with conjunctival auto-graft (CAG) further decreases its recurrence. A prospective, clinical open trial of 50 eyes of 50 patients with recurrent pterygium, who were randomly assigned to either, pterygium excision and CAG with fibrin glue (Group 1) or with 6 interrupted sutures (Group 2), was carried out from January 2009 to July 2010 at the outpatient department of Subharti Medical College, Meerut, North India. Both groups had 25 patients each. The groups were compared with regards to the surgical time taken, development of recurrence, postoperative symptoms (irritation, watering, and redness), and complications. Recurrence was seen in one (4%) eye in group I, and 3 (12%) eyes in group II after 9-13 months of follow up. The difference between the 2 groups was not statistically significant. The surgical time was significantly reduced, and postoperative inflammation and complications were less in group I. Postoperative symptoms were significantly more in group II patients. While conjunctival autograft with sutures for management of recurrent pterygium appears to be a safe and feasible modality, fibrin glue fixation of the autograft is a more viable option in terms of surgical ease, less time consuming, less postoperative complications, and less recurrence (Author).

  13. Re: Fibrin Glue Injections: A Minimally Invasive and Cost-Effective Treatment for Post-Renal Transplant Lymphoceles and Lymph Fistulas

    Directory of Open Access Journals (Sweden)

    Presser N

    2016-03-01

    Full Text Available In this retrospective study, 46 (2.7% patients out of 1662 kidney transplant recipients had developed symptomatic lymphocele/lymph fistula requiring intervention over an 11-year period. Open surgical drainage (22, laparoscopic surgical drainage (11 and percutaneous fibrin glue injections into the drained lymphocele cavity (13 were used to treat this complication. Besides being effective both on the early and late developed lymphoceles, significantly lower recurrence rates by fibrin glue injections and lower median treatment costs were observed when compared with the other two surgical modalities. It has also the advantage of an outpatient procedure that can be performed using fluoroscopic guidance, under local anesthesia. However, due to era effect, most of the open and laparoscopic surgical recipients were treated with sirolimus, a well-known antiproliferative immunosuppressive agent, which can promote development of lymphoceles and surgical failure. However, the majority of fibrin glue-treated cases were with tacrolimus-based regimens, but this study, in its nature, is far from giving the answer for decreased number of recurrences with fibrin glue

  14. The impact of the centrifuge characteristics and centrifugation protocols on the cells, growth factors, and fibrin architecture of a leukocyte- and platelet-rich fibrin (L-PRF) clot and membrane.

    Science.gov (United States)

    Dohan Ehrenfest, David M; Pinto, Nelson R; Pereda, Andrea; Jiménez, Paula; Corso, Marco Del; Kang, Byung-Soo; Nally, Mauricio; Lanata, Nicole; Wang, Hom-Lay; Quirynen, Marc

    2018-03-01

    -PRF. All centrifugations were done using the original L-PRF centrifuge (Intra-Spin), as recommended by the two manufacturers. Half of the membranes were placed individually in culture media and transferred in a new tube at seven experimental times (up to 7 days). The releases of transforming growth factor β-1 (TGFβ-1), platelet derived growth factor AB (PDGF-AB), vascular endothelial growth factor (VEGF) and bone morphogenetic protein 2 (BMP-2) were quantified using ELISA kits at these seven experimental times. The remaining membranes were used to evaluate the initial quantity of growth factors of the L-PRF and A-PRF membranes, through forcible extraction. Very significant differences in the level of vibrations at each rotational speed were observed between the four tested centrifuges. The original L-PRF centrifuge (Intra-Spin) was by far the most stable machine in all configurations and always remained under the threshold of resonance, unlike the three other tested machines. At the classical speed of production of L-PRF, the level of undesirable vibrations on the original centrifuge was between 4.5 and 6 times lower than with other centrifuges. Intra-Spin showed the lowest temperature of the tubes. A-PRF and Salvin were both associated with a significant increase in temperature in the tube. Intra-Spin produced the heaviest clot and quantity of exudate among the four techniques. A-PRF and LW produced much lighter, shorter and narrower clots and membranes than the two other centrifuges. Light microscopy analysis showed relatively similar features for all L-PRF types (concentration of cell bodies in the first half). However, SEM illustrated considerable differences between samples. The original Intra-Spin L-PRF showed a strongly polymerized thick fibrin matrix and all cells appeared alive with a normal shape, including the textured surface aspect of activated lymphocytes. The A-PRF, Salvin and LW PRF-like membranes presented a lightly polymerized slim fibrin gel and most

  15. Fractional order analysis of Sephadex gel structures: NMR measurements reflecting anomalous diffusion

    Science.gov (United States)

    Magin, Richard L.; Akpa, Belinda S.; Neuberger, Thomas; Webb, Andrew G.

    2011-12-01

    We report the appearance of anomalous water diffusion in hydrophilic Sephadex gels observed using pulse field gradient (PFG) nuclear magnetic resonance (NMR). The NMR diffusion data was collected using a Varian 14.1 Tesla imaging system with a home-built RF saddle coil. A fractional order analysis of the data was used to characterize heterogeneity in the gels for the dynamics of water diffusion in this restricted environment. Several recent studies of anomalous diffusion have used the stretched exponential function to model the decay of the NMR signal, i.e., exp[-( bD) α], where D is the apparent diffusion constant, b is determined the experimental conditions (gradient pulse separation, durations and strength), and α is a measure of structural complexity. In this work, we consider a different case where the spatial Laplacian in the Bloch-Torrey equation is generalized to a fractional order model of diffusivity via a complexity parameter, β, a space constant, μ, and a diffusion coefficient, D. This treatment reverts to the classical result for the integer order case. The fractional order decay model was fit to the diffusion-weighted signal attenuation for a range of b-values (0 < b < 4000 s mm -2). Throughout this range of b values, the parameters β, μ and D, were found to correlate with the porosity and tortuosity of the gel structure.

  16. Evaluation of fibrin-gelatin hydrogel as biopaper for application in skin bioprinting: An in-vitro study.

    Science.gov (United States)

    Hakam, Mohammad Sadjad; Imani, Rana; Abolfathi, Nabiollah; Fakhrzadeh, Hossein; Sharifi, Ali Mohammad

    2016-01-01

    Recent advances in tissue engineering have led to the development of the concept of bioprinting as an interesting alternative to traditional tissue engineering approaches. Biopaper, a biomimetic hydrogel, is an essential component of the bioprinting process. The aim of this work was to synthesize a biopaper made of fibrin-gelatin hybrid hydrogel for application in skin bioprinting. Different composition percentages of the two biopolymer hydrogels, fibrin-gelatin, have been studied for the construction of the biopaper and were examined in terms of water absorption, biodegradability, glucose absorption, mechanical properties and water vapor transmission. Subsequently, tissue fusion study was performed on prepared 3T3 fibroblast cell line pellets embedded into the hydrogel. Based on the obtained results, fibrin-gelatin blend hydrogel with the same proportion of two components provides a natural scaffold for fibroblast-based bioink embedding and culture. The suggested optimized hydrogel was a suitable candidate as a biopaper for skin bioprinting technology.

  17. Evaluation of osteoblastic activity in extraction sockets treated with platelet-rich fibrin.

    Science.gov (United States)

    Baslarli, Ozgur; Tumer, Celal; Ugur, Omer; Vatankulu, Betul

    2015-01-01

    The aim of this study was to determine whether the use of platelet rich fibrin (PRF) improved the healing of extraction sockets. A total of 20 patients with bilateral soft tissue impacted mandibular third molars were included in this study. The left and right third molars were extracted during the same session. Subsequently, the PRF membrane was randomly administered to one of the extraction sockets, whereas the contralateral sockets were left without treatment. On postoperative 30. and 90. days, panoramic images and bone scintigrams were taken to evaluate the bone healing between PRF-treated and non-PRF-treated sockets. Also, periodontal evaluation was performed in the same control sessions. Dependent group t test for paired samples was used for statistical analysis. The average increase in technetium-99m methylene diphosphonate uptake as an indication of enhanced bone healing did not differ significantly between PRF-treated and non-PRF-treated sockets 30 and 90 days postoperatively. Radio-opacity that can show the bone healing on panoramic images were measured by Image J programme and they did not differ significantly. Also periodontal values did not differ significantly. PRF might not lead to enhanced bone healing in impacted mandibular third molar extraction sockets 30 and 90 days after surgery. It is thought that PRF has the potential characteristics of an autologous fibrin matrix and can accelerate the healing. To better understand the effects of PRF on healing, further research is warranted with larger sample sizes.

  18. Management of an extrasphincteric fistula in an HIV-positive patient by using fibrin glue: a case report with tips and tricks

    Directory of Open Access Journals (Sweden)

    Sapalidis Konstantinos

    2010-02-01

    Full Text Available Abstract Background Individuals with impaired immunity are at higher risk of perianal diseases. Concerning complex anal fistulas impaired healing and complication rates are also higher. Definitive treatment of a fistula aims controlling the purulent discharge and prevents its recurrence. It depends mainly on the trajectory of the fistula and the underlying disease. We present a case of a HIV-positive patient with a complex extrasphincteric anal fistula who was treated successfully with fibrin glue application. We further, discuss tips and tricks when applying fibrin glue as plugging material in complex anal fistulas. Case presentation A sixty-one-year-old HIV-positive male referred to us for warts and extrasphincteric fistula. Because of the patients' immunological status, we opted against surgery and recommended fibrin glue plugging. The patient was discharged the same day. A follow-up examination was performed 5 days after the initial fibrin glue application showing that the fistula canal was obstructed. Three months and a year post-intervention the fistula tract remains closed. Conclusion The best treatment for a disease gives at least the same result with the other treatments with minimised risk for the life of the patient and minimal application effort. Conservative closure of fistula with fibrin plugging is simple, safe and with less morbidity than surgery. Our patient was successfully treated without endangering his life despite his precarious medical state. Not everybody believes in the effectiveness of fibrin glue application, however we consider this solution in cases of complex fistulas at least as primary procedure in special populations such as the immunosupressed.

  19. Fixation of split-thickness skin graft using fast-clotting fibrin glue containing undiluted high-concentration thrombin or sutures: a comparison study.

    Science.gov (United States)

    Han, Hyun Ho; Jun, Daiwon; Moon, Suk-Ho; Kang, In Sook; Kim, Min Cheol

    2016-01-01

    For skin defects caused by full-thickness burns, trauma, or tumor tissue excision, skin grafting is one of the most convenient and useful treatment methods. In this situation, graft fixation is important in skin grafting. This study was performed to compare the effectiveness of skin graft fixation between high-concentration fibrin sealant and sutures. There have been numerous studies using fibrin sealant for graft fixation, but they utilized slow-clotting fibrin sealant containing less than 10 IU/mL thrombin. Twenty-five patients underwent split-thickness skin grafting using fast-clotting fibrin sealant containing 400 IU/mL thrombin, while 30 patients underwent grafting using sutures. Rates of hematoma/seroma formation, graft dislocation, graft necrosis, and graft take were investigated postoperatively. The graft surface area was calculated using Image J software (National Institutes of Health, Bethesda, MD, USA). After 5 days, rates of hematoma/seroma formation and graft dislocation were 7.84 and 1.29% in group I, and 9.55 and 1.45% in group II, respectively. After 30 days, rates of graft necrosis and graft take were 1.86 and 98.14% in group I, and 4.65 and 95.35% in group II. Undiluted fibrin sealant showed significantly superior results for all rates ( p  < 0.05) except graft dislocation. When high-concentration fast-clotting fibrin sealant was applied to skin grafts without dilution, no difficulty was experienced during surgery. Sealant showed superior results compared with sutures and had an excellent graft take rate. II.

  20. Study of some parameters of the fibrinogen - fibrin transformation reaction

    International Nuclear Information System (INIS)

    Hollard, D.; Suscillon, M.; Marcille, G.; Rambaud, F.; Baloyan, M.

    1966-01-01

    The authors studied the action of some parameters on the reaction of transformation fibrinogen-fibrin. The five parameters studied are: the concentration of substratum: a certain quantity of enzyme determines an optimum quantity of fibrinogen; the concentration of enzyme: a certain quantity of substratum defines an optimum quantity of enzyme, beyond which the excess of enzyme is unable to act, the substratum being saturated by the enzyme; the concentration of Ca ions: between 0,07 and 0,10 mg of Ca by mg of fibrinogen, the reaction appears with a great speed. Between 0,02 and 0,40 mg of Ca by mg of fibrinogen the fibrin stabilisation is possible, the FSF can act only inside the definite bounds; the ph of the solution: the reaction of the transformation appears with its maximum intensity on physiological ph, the polymerisation is not possible on acid ph; the temperature has an effect which could not really be verified owing to the fact that the technical realisation is difficult. (author) [fr

  1. Structure of mineral gels

    International Nuclear Information System (INIS)

    Miranda Salvado, I.M.; Margaca, F.M.A.; Teixeira, J.

    1999-01-01

    Small Angle Neutron Scattering (SANS) measurements have been performed to investigate the nanoscale structure of materials of the systems xTiO 2 -(1-x)SiO 2 and xZrO 2 -(1-x)SiO 2 with x ≤ 10 mol % at different processing stages. The materials were prepared by sol-gel using the alkoxides method, in strong acidic conditions. Samples were studied as xerogels heat-treated at 120 and 850 deg. C and as wet gels at gel point and after aging. All samples showed identical microstructure at gel point, extended linear chains ∼10 nm long. The aged gel has a mass fractal structure with fractal dimension of 1.7 - 1.9. The 120 deg. C heat-treated xerogels show homogeneous oxide regions with mass fractal structure. For the 850 deg. C heat-treated xerogel the oxide regions average size has reduced and it has densified as compared to 120 deg. C heat-treated sample. (author)

  2. Fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses

    Directory of Open Access Journals (Sweden)

    Eliseo Portilla-de Buen

    2014-04-01

    Full Text Available OBJECTIVE: Fibrin glues have not been consistently successful in preventing the dehiscence of high-risk colonic anastomoses. Fibrinogen and thrombin concentrations in glues determine their ability to function as sealants, healers, and/or adhesives. The objective of the current study was to compare the effects of different concentrations of fibrinogen and thrombin on bursting pressure, leaks, dehiscence, and morphology of high-risk ischemic colonic anastomoses using fibrin glue in rats. METHODS: Colonic anastomoses in adult female Sprague-Dawley rats (weight, 250-350 g treated with fibrin glue containing different concentrations of fibrinogen and thrombin were evaluated at post-operative day 5. The interventions were low-risk (normal or high-risk (ischemic end-to-end colonic anastomoses using polypropylene sutures and topical application of fibrinogen at high (120 mg/mL or low (40 mg/mL concentrations and thrombin at high (1000 IU/mL or low (500 IU/mL concentrations. RESULTS: Ischemia alone, anastomosis alone, or both together reduced the bursting pressure. Glues containing a low fibrinogen concentration improved this parameter in all cases. High thrombin in combination with low fibrinogen also improved adherence exclusively in low-risk anastomoses. No differences were detected with respect to macroscopic parameters, histopathology, or hydroxyproline content at 5 days post-anastomosis. CONCLUSIONS: Fibrin glue with a low fibrinogen content normalizes the bursting pressure of high-risk ischemic left-colon anastomoses in rats at day 5 after surgery.

  3. Preliminary report of a sutureless onlay technique for incisional hernia repair using fibrin glue alone for mesh fixation.

    Science.gov (United States)

    Stoikes, Nathaniel; Webb, David; Powell, Ben; Voeller, Guy

    2013-11-01

    The Rives repair for ventral/incisional (V/I) hernias involves sublay mesh placement requiring retrorectus dissection and transfascial stitches. Chevrel described a repair by onlaying mesh after a unique primary fascial closure. Although Chevrel fixated mesh to the anterior fascia with sutures, he used fibrin glue for fascial closure reinforcement. We describe an onlay technique with mesh fixated to the anterior fascia solely with fibrin glue without suture fixation. From January 2010 to January 2012, 50 patients underwent a V/I hernia onlay technique with fibrin glue mesh fixation. Records were reviewed for technical details, demographics, mesh characteristics, and postoperative outcomes. Primary fascial closure with interrupted permanent suture was done with or without myofascial advancement flaps. Onlay polypropylene mesh was placed providing 8 cm of overlap. Fibrin glue was applied over the prosthesis and subcutaneous drains were placed. Mean age was 62.4 years. Mean body mass index was 30.1 kg/m(2). Average mesh size was 14.5 cm × 19.1 cm. Mean operative time was 144.4 minutes (range, 38 to 316 minutes). Mean discharge was postoperative Day 2.9 (range, 0 to 15 days). Morbidity included eight seromas, one hematoma, and three wound infections. Seventeen patients required components separation. Mean follow-up was 19.5 months with no recurrences. This is the first series describing fibrin glue alone for mesh fixation for V/I hernia repair. It allows for immediate prosthesis fixation to the anterior fascia. Early results are promising. Potential advantages include less operative time, less technical difficulty, and less long-term pain. A prospective trial is needed to evaluate this approach.

  4. Polymer gel measurement of dose homogeneity in the breast: comparing MLC intensity modulation with standard wedged delivery

    International Nuclear Information System (INIS)

    Love, P A; Evans, P M; Leach, M O; Webb, S

    2003-01-01

    Polymer gel dosimetry has been used to measure the radiotherapy dose homogeneity in a breast phantom for two different treatment methods. The first 'standard' method uses two tangential wedged fields while the second method has three static fields shaped by multileaf collimators (MLCs) in addition to the standard wedged fields to create intensity modulated fields. Gel dose distributions from the multileaf modulation treatment show an improved dose uniformity in comparison to the standard treatment with a decreased volume receiving doses over 105%

  5. Gallium/sup 67/ scintigraphy in fibrinous pericarditis associated with bacterial endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Martin, P; Verhas, M; Devriendt, J; Goffin, Y

    1982-04-01

    An 80-year-old man presented with pyrexia, progressive cardiac failure and inflammation. A diagnosis of pericarditis associated with bacterial endocarditis was suggested from Gallium 67 scintigraphy and confirmed at autopsy. This case of fibrinous pericarditis without effusion could not be diagnosed by echography or routine cardiopulmonary scintigraphy.

  6. Yield stress determination of a physical gel

    DEFF Research Database (Denmark)

    Hvidt, Søren

    2013-01-01

    Pluronic F127 solutions form gels in water with high elastic moduli. Pluronic gels can, however, only withstand small deformations and stresses. Different steady shear and oscillatory methods traditionally used to determine yield stress values are compared. The results show that the yield stresses...... values of these gels depend on test type and measurement time, and no absolute yield stress value can be determined for these physical gels....

  7. Low-thrombogenic fibrin-heparin coating promotes in vitro endothelialization

    Czech Academy of Sciences Publication Activity Database

    Kaplan, Ondřej; Hierlemann, T.; Krajewski, S.; Kurz, J.; Nevoralová, Martina; Houska, Milan; Riedel, Tomáš; Riedelová, Zuzana; Zárubová, Jana; Wendel, H. P.; Brynda, Eduard

    2017-01-01

    Roč. 105, č. 11 (2017), s. 2995-3005 ISSN 1549-3296 R&D Projects: GA MZd(CZ) NV15-29153A Institutional support: RVO:61389013 ; RVO:67985823 Keywords : fibrin-heparin coating * hemocompatibility * endothelialization Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery; FA - Cardiovascular Diseases incl. Cardiotharic Surgery (FGU-C) OBOR OECD: Cardiac and Cardiovascular systems; Cardiac and Cardiovascular systems (FGU-C) Impact factor: 3.076, year: 2016

  8. Platelet-rich fibrin matrix for facial plastic surgery.

    Science.gov (United States)

    Sclafani, Anthony P; Saman, Masoud

    2012-05-01

    Platelets are known primarily for their role in hemostasis, but there is increasing interest in the effect of platelets on wound healing. Platelet isolates such as platelet-rich plasma have been advocated to enhance and accelerate wound healing. This article describes the use of a novel preparation, platelet-rich fibrin matrix (PRFM), for facial plastic surgery applications such as volume augmentation, fat transfer supplementation, and as an adjunct to open surgical procedures. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Polymer gel dosimeters with enhanced sensitivity for use in x-ray CT polymer gel dosimetry

    International Nuclear Information System (INIS)

    Jirasek, A; Hilts, M; McAuley, K B

    2010-01-01

    A primary limitation of current x-ray CT polymer gel dosimetry is the low contrast, and hence poor dose resolution, of dose images produced by the system. The low contrast is largely due to the low-dose sensitivity of current formulations of polymer gel for x-ray CT imaging. This study reports on the investigation of new dosimeter formulations with improved dose sensitivity for x-ray CT polymer gel dosimetry. We incorporate an isopropanol co-solvent into an N-isopropylacrylamide-based gel formulation in order to increase the total monomer/crosslinker concentration (%T) within the formulation. It is shown that gels of high %T exhibit enhanced dose sensitivity and dose resolutions over traditional formulations. The gels are shown to be temporally stable and reproducible. A single formulation (16%T) is used to demonstrate the capabilities of the x-ray CT polymer gel dosimetry system in measuring known dose distributions. A 1 L gel volume is exposed to three separate irradiations: a single-field percent depth dose, a two-field 'cross' and a three-field 'test case'. The first two irradiations are used to generate a dose calibration curve by which images are calibrated. The calibrated images are compared with treatment planning predictions and it is shown that the x-ray CT polymer gel dosimetry system is capable of capturing spatial and dose information accurately. The proposed new gel formulation is shown to be sensitive, stable and to improve the dose resolution over current formulations so as to provide a feasible gel for clinical applications of x-ray CT polymer gel dosimetry.

  10. Fixation of osteochondral fractures in rabbit knees. A comparison of Kirschner wires, fibrin sealant, and polydioxanone pins.

    Science.gov (United States)

    Plaga, B R; Royster, R M; Donigian, A M; Wright, G B; Caskey, P M

    1992-03-01

    We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation was used. One animal from each group was killed at two, three and four weeks. The remaining rabbits were killed at six weeks. A fracture which healed with less than 1 mm of displacement was considered a success. There was successful healing in 29% of the control group, in all of the Kirschner-wire group, in 50% of the fibrin-sealant group, and in 86% of the PDS-pin group. The use of PDS pins appears to be a reliable alternative to the use of metal in the fixation of osteochondral fractures in rabbits.

  11. Fibrin sealants or cell saver eliminate the need for autologous blood donation in anemic patients undergoing primary total knee arthroplasty.

    Science.gov (United States)

    Bou Monsef, Jad; Buckup, Johannes; Waldstein, Wenzel; Cornell, Charles; Boettner, Friedrich

    2014-01-01

    Reducing allogeneic blood transfusions remains a challenge in total knee arthroplasty. Patients with preoperative anemia have a particularly high risk for perioperative blood transfusions. 176 anemic patients (Hb < 13.5 g/dl) undergoing total knee replacement were prospectively evaluated to compare the effect of a perioperative cell saver (26 patients), intraoperative fibrin sealants (5 ml Evicel, Johnson & Johnson Wound Management, Ethicon, Somerville, NJ) (45 patients), preoperative autologous blood donation (PABD) (21 patients), the combination of fibrin sealants and preoperative autologous blood donation (44) and no intervention (40 patients) on perioperative blood loss and transfusion requirements. All protocols resulted in significant reduction of allogeneic blood transfusions. Transfusion rates were similar with the use of PABD (19%), Evicel (18%), and cell saver (19%), all significantly lower than the control group (38 %, p < 0.05). Combining Evicel with PABD resulted in significantly higher wastage of autologous units (p < 0.05) with no significant reduction in allogeneic transfusion rate (14%). The use of fibrin sealant resulted in a significant reduction of blood loss compared to the PABD group (603 vs. 810 ml, p < 0.005) as well as the control group (603 vs. 822 ml, p < 0.005). While PABD proved to be the most cost-effective treatment option in anemic patients, fibrin sealants and cell saver show similar reduction in allogeneic transfusion rates compared to controls. The combination of fibrin sealants and PABD is not cost-effective and increases the number of wasted units.

  12. Development of novel sol-gel indicators (SGI's) for in-situ environmental measurements

    International Nuclear Information System (INIS)

    Livingston, R.R.; Wicks, G.G.; Baylor, L.C.; Whitaker, M.J.

    1993-01-01

    Organic indicator molecules have been incorporated in a porous sol- gel matrix coated on the end of a fiber-optic lens assembly to create sensors for in situ environmental measurements. Probes have been made that are sensitive to pH and uranyl concentration. The use of fiber optics allows the probe to be lowered into a well or bore hole, while support equipment such as a spectrophotometer and computer may be situated hundreds of meters away

  13. Clot retraction is mediated by factor XIII-dependent fibrin-αIIbβ3-myosin axis in platelet sphingomyelin-rich membrane rafts.

    Science.gov (United States)

    Kasahara, Kohji; Kaneda, Mizuho; Miki, Toshiaki; Iida, Kazuko; Sekino-Suzuki, Naoko; Kawashima, Ikuo; Suzuki, Hidenori; Shimonaka, Motoyuki; Arai, Morio; Ohno-Iwashita, Yoshiko; Kojima, Soichi; Abe, Mitsuhiro; Kobayashi, Toshihide; Okazaki, Toshiro; Souri, Masayoshi; Ichinose, Akitada; Yamamoto, Naomasa

    2013-11-07

    Membrane rafts are spatially and functionally heterogenous in the cell membrane. We observed that lysenin-positive sphingomyelin (SM)-rich rafts are identified histochemically in the central region of adhered platelets where fibrin and myosin are colocalized on activation by thrombin. The clot retraction of SM-depleted platelets from SM synthase knockout mouse was delayed significantly, suggesting that platelet SM-rich rafts are involved in clot retraction. We found that fibrin converted by thrombin translocated immediately in platelet detergent-resistant membrane (DRM) rafts but that from Glanzmann's thrombasthenic platelets failed. The fibrinogen γ-chain C-terminal (residues 144-411) fusion protein translocated to platelet DRM rafts on thrombin activation, but its mutant that was replaced by A398A399 at factor XIII crosslinking sites (Q398Q399) was inhibited. Furthermore, fibrin translocation to DRM rafts was impaired in factor XIII A subunit-deficient mouse platelets, which show impaired clot retraction. In the cytoplasm, myosin translocated concomitantly with fibrin translocation into the DRM raft of thrombin-stimulated platelets. Furthermore, the disruption of SM-rich rafts by methyl-β-cyclodextrin impaired myosin activation and clot retraction. Thus, we propose that clot retraction takes place in SM-rich rafts where a fibrin-αIIbβ3-myosin complex is formed as a primary axis to promote platelet contraction.

  14. Novel sulfated xylogalactoarabinans from green seaweed Cladophora falklandica: Chemical structure and action on the fibrin network.

    Science.gov (United States)

    Arata, Paula X; Quintana, Irene; Raffo, María Paula; Ciancia, Marina

    2016-12-10

    The water-soluble sulfated xylogalactoarabinans from green seaweed Cladophora falklandica are constituted by a backbone of 4-linked β-l-arabinopyranose units partially sulfated mainly on C3 and also on C2. Besides, partial glycosylation mostly on C2 with single stubs of β-d-xylopyranose, or single stubs of β-d-galactofuranose or short chains comprising (1→5)- and/or (1→6)-linkages, was also found. These compounds showed anticoagulant activity, although much lower than that of heparin. The effect of a purified fraction (F1) on the fibrin network was studied in detail. It modifies the kinetics of fibrin formation, suggesting an impaired polymerization process. Scanning electron microscopy showed a laxer conformation, with larger interstitial pores than the control. Accordingly, this network was lysed more easily. These fibrin properties would reduce the time of permanence of the clot in the blood vessel, inducing a lesser thrombogenic state. One of the possible mechanisms of its anticoagulant effect is direct thrombin inhibition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of bang polymer gel dosimeters

    International Nuclear Information System (INIS)

    Ibbott, Geoffrey S.; Maryanski, Marek J.; Eastman, Peter; Holcomb, Stephen D.; Yashan, Zhang; Avison, Robin G.; Sanders, Michael; Gore, John C.

    1997-01-01

    Purpose/Objective: The measurement of complex dose distributions (those created by irradiation through multiple beams, multiple sources, or multiple source dwell positions) requires a dosimeter that can integrate the dose during a complete treatment. Integrating dosimeter devices generally are capable of measuring only dose at a point (ion chamber, diode, TLD) or in a plane (film). With increasing use of conformal dose distributions requiring shaped, non coplanar beams, there will be an increased requirement for a dosimeter that can record and display a 3D dose distribution. The use of a 3D dosimeter will be required to confirm the accuracy of treatment plans produced by the current generation of 3D treatment-planning computers. Methods and Materials: The use of a Fricke-infused gel and magnetic resonance imaging (MRI) to demonstrate the localization of stereotactic beams has been demonstrated (11). The recently developed BANG polymer gel dosimetry system (MGS Research, Inc., Guilford, CT), based on radiation-induced chain polymerization of acrylic monomers dispersed in a tissue-equivalent gel, surpasses the Fricke-gel method by providing accurate, quantitative dose distribution data that do not deteriorate with time (6, 9). The improved BANG2 formulation contains 3% N,N'-methylene-bis acrylamide, 3% acrylic acid, 1% sodium hydroxide, 5% gelatin, and 88% water, where all percentages are by weight. The gel was poured into volumetric flasks, of dimensions comparable to a human head. The gels were irradiated with complex beam arrangements, similar to those used for conformal radiation therapy. Images of the gels were acquired using a Siemens 1.5T imager and a Hahn spin-echo pulse sequence (90 deg. -τ-180 deg. -τ-acquire, for different values of τ). The images were transferred via network to a Macintosh computer for which a data analysis and display program was written. The program calculates R2 maps on the basis of multiple TE images, using a monoexponential

  16. Enhancement of the repair of dog alveolar cleft by an autologous iliac bone, bone marrow-derived mesenchymal stem cell, and platelet-rich fibrin mixture.

    Science.gov (United States)

    Yuanzheng, Chen; Yan, Gao; Ting, Li; Yanjie, Fu; Peng, Wu; Nan, Bai

    2015-05-01

    Autologous bone graft has been regarded as the criterion standard for the repair of alveolar cleft. However, the most prominent issue in alveolar cleft treatment is the high absorption rate of the bone graft. The authors' objective was to investigate the effects of an autologous iliac bone, bone marrow-derived mesenchymal stem cell, and platelet-rich fibrin mixture on the repair of dog alveolar cleft. Twenty beagle dogs with unilateral alveolar clefts created by surgery were divided randomly into four groups: group A underwent repair with an autologous iliac bone, bone marrow-derived mesenchymal stem cell, and platelet-rich fibrin mixture; group B underwent repair with autologous iliac bone and bone marrow-derived mesenchymal stem cells; group C underwent repair with autologous iliac bone and platelet-rich fibrin; and group D underwent repair with autologous iliac bone as the control. One day and 6 months after transplantation, the transplant volumes and bone mineral density were assessed by quantitative computed tomography. All of the transplants were harvested for hematoxylin and eosin staining 6 months later. Bone marrow-derived mesenchymal stem cells and platelet-rich fibrin transplants formed the greatest amounts of new bone among the four groups. The new bone formed an extensive union with the underlying maxilla in groups A, B, and C. Transplants with the bone marrow-derived mesenchymal stem cells, platelet-rich fibrin, and their mixture retained the majority of their initial volume, whereas the transplants in the control group showed the highest absorption rate. Bone mineral density of transplants with the bone marrow-derived mesenchymal stem cells, platelet-rich fibrin, and their mixture 6 months later was significantly higher than in the control group (p platelet-rich fibrin mixed transplants. Hematoxylin and eosin staining showed that the structure of new bones formed the best in group A. Both bone marrow-derived mesenchymal stem cells and platelet

  17. Randomized clinical trial of fibrin sealant versus titanium tacks for mesh fixation in laparoscopic umbilical hernia repair

    DEFF Research Database (Denmark)

    Eriksen, J R; Bisgaard, T; Assaadzadeh, S

    2011-01-01

    The use of tacks for mesh fixation may induce pain after surgery for ventral hernia. The aim of this study was to compare postoperative pain after laparoscopic ventral hernia repair (LVHR) with conventional mesh fixation using titanium tacks versus fibrin sealant (FS).......The use of tacks for mesh fixation may induce pain after surgery for ventral hernia. The aim of this study was to compare postoperative pain after laparoscopic ventral hernia repair (LVHR) with conventional mesh fixation using titanium tacks versus fibrin sealant (FS)....

  18. Effect of fibrin glue on the biomechanical properties of human Descemet's membrane.

    Directory of Open Access Journals (Sweden)

    Shyam S Chaurasia

    Full Text Available BACKGROUND: Corneal transplantation has rapidly evolved from full-thickness penetrating keratoplasty (PK to selective tissue corneal transplantation, where only the diseased portions of the patient's corneal tissue are replaced with healthy donor tissue. Descemet's membrane endothelial keratoplasty (DMEK performed in patients with corneal endothelial dysfunction is one such example where only a single layer of endothelial cells with its basement membrane (10-15 µm in thickness, Descemet's membrane (DM is replaced. It is challenging to replace this membrane due to its intrinsic property to roll in an aqueous environment. The main objective of this study was to determine the effects of fibrin glue (FG on the biomechanical properties of DM using atomic force microscopy (AFM and relates these properties to membrane folding propensity. METHODOLOGY/PRINCIPAL FINDINGS: Fibrin glue was sprayed using the EasySpray applicator system, and the biomechanical properties of human DM were determined by AFM. We studied the changes in the "rolling up" tendency of DM by examining the changes in the elasticity and flexural rigidity after the application of FG. Surface topography was assessed using scanning electron microscopy (SEM and AFM imaging. Treatment with FG not only stabilized and stiffened DM but also led to a significant increase in hysteresis of the glue-treated membrane. In addition, flexural or bending rigidity values also increased in FG-treated membranes. CONCLUSIONS/SIGNIFICANCE: Our results suggest that fibrin glue provides rigidity to the DM/endothelial cell complex that may aid in subsequent manipulation by maintaining tissue integrity.

  19. Effect of Fibrin Glue on the Biomechanical Properties of Human Descemet's Membrane

    Science.gov (United States)

    Chaurasia, Shyam S.; Champakalakshmi, Ravi; Li, Ang; Poh, Rebekah; Tan, Xiao Wei; Lakshminarayanan, Rajamani; Lim, Chwee T.; Tan, Donald T.; Mehta, Jodhbir S.

    2012-01-01

    Background Corneal transplantation has rapidly evolved from full-thickness penetrating keratoplasty (PK) to selective tissue corneal transplantation, where only the diseased portions of the patient's corneal tissue are replaced with healthy donor tissue. Descemet's membrane endothelial keratoplasty (DMEK) performed in patients with corneal endothelial dysfunction is one such example where only a single layer of endothelial cells with its basement membrane (10–15 µm in thickness), Descemet's membrane (DM) is replaced. It is challenging to replace this membrane due to its intrinsic property to roll in an aqueous environment. The main objective of this study was to determine the effects of fibrin glue (FG) on the biomechanical properties of DM using atomic force microscopy (AFM) and relates these properties to membrane folding propensity. Methodology/Principal Findings Fibrin glue was sprayed using the EasySpray applicator system, and the biomechanical properties of human DM were determined by AFM. We studied the changes in the “rolling up” tendency of DM by examining the changes in the elasticity and flexural rigidity after the application of FG. Surface topography was assessed using scanning electron microscopy (SEM) and AFM imaging. Treatment with FG not only stabilized and stiffened DM but also led to a significant increase in hysteresis of the glue-treated membrane. In addition, flexural or bending rigidity values also increased in FG-treated membranes. Conclusions/Significance Our results suggest that fibrin glue provides rigidity to the DM/endothelial cell complex that may aid in subsequent manipulation by maintaining tissue integrity. PMID:22662156

  20. Unfavorably Altered Fibrin Clot Properties in Patients with Eosinophilic Granulomatosis with Polyangiitis (Churg-Strauss Syndrome): Association with Thrombin Generation and Eosinophilia.

    Science.gov (United States)

    Mastalerz, Lucyna; Celińska-Lӧwenhoff, Magdalena; Krawiec, Piotr; Batko, Bogdan; Tłustochowicz, Witold; Undas, Anetta

    2015-01-01

    Given reports on the increased prevalence of thromboembolic incidents in patients with eosinophilic granulomatosis with polyangiitis (EGPA; Churg-Strauss syndrome), we investigated whether fibrin clot properties are unfavorably altered in EGPA. Ex vivo plasma fibrin clot characteristics, including clot permeability, turbidimetry and efficiency of fibrinolysis using two assays, were investigated in 34 consecutive patients with remission in EGPA according to the Birmingham Vasculitis Activity Score version 3 (23 female, 11 male), aged 48 (range, 21-80) years. The control group comprised 34 age- and sex- matched volunteers. Compared with controls, patients with EGPA were characterized by denser fiber clots (estimated pore size, Ks, 7.30±0.93 vs 10.14±1.07 10-9 cm2), faster fibrin polymerization (lag phase in a turbidimetric curve, 41.8±3.6 vs 47.4±2.9 s), thicker fibrin fibers (maximum absorbance, ΔAbs, 0.87±0.09 vs 0.72±0.07), higher maximum levels of D-dimer released from clots (DDmax 4.10±0.46 vs 3.54±0.35 mg/L), and prolonged clot lysis time (t50%; 9.50±1.45 vs 7.56±0.87 min); all p<0.0001. Scanning electron microscopy images confirmed denser plasma fibrin networks composed of thinner fibers formed in EGPA. Antineutrophil cytoplasmic antibody status and C-reactive protein did not affect clot variables. Multivariate analysis adjusted for fibrinogen showed that Ks was predicted by eosinophil count, peak thrombin generation, factor VIII, and soluble CD40 ligand, whereas eosinophil count, peak thrombin generation and antiplasmin predicted t50%. This study is the first to show that EGPA is associated with prothrombotic plasma fibrin clot phenotype, which may contribute to thromboembolic manifestations reported in this disease.

  1. Unfavorably Altered Fibrin Clot Properties in Patients with Eosinophilic Granulomatosis with Polyangiitis (Churg-Strauss Syndrome: Association with Thrombin Generation and Eosinophilia.

    Directory of Open Access Journals (Sweden)

    Lucyna Mastalerz

    Full Text Available Given reports on the increased prevalence of thromboembolic incidents in patients with eosinophilic granulomatosis with polyangiitis (EGPA; Churg-Strauss syndrome, we investigated whether fibrin clot properties are unfavorably altered in EGPA.Ex vivo plasma fibrin clot characteristics, including clot permeability, turbidimetry and efficiency of fibrinolysis using two assays, were investigated in 34 consecutive patients with remission in EGPA according to the Birmingham Vasculitis Activity Score version 3 (23 female, 11 male, aged 48 (range, 21-80 years. The control group comprised 34 age- and sex- matched volunteers.Compared with controls, patients with EGPA were characterized by denser fiber clots (estimated pore size, Ks, 7.30±0.93 vs 10.14±1.07 10-9 cm2, faster fibrin polymerization (lag phase in a turbidimetric curve, 41.8±3.6 vs 47.4±2.9 s, thicker fibrin fibers (maximum absorbance, ΔAbs, 0.87±0.09 vs 0.72±0.07, higher maximum levels of D-dimer released from clots (DDmax 4.10±0.46 vs 3.54±0.35 mg/L, and prolonged clot lysis time (t50%; 9.50±1.45 vs 7.56±0.87 min; all p<0.0001. Scanning electron microscopy images confirmed denser plasma fibrin networks composed of thinner fibers formed in EGPA. Antineutrophil cytoplasmic antibody status and C-reactive protein did not affect clot variables. Multivariate analysis adjusted for fibrinogen showed that Ks was predicted by eosinophil count, peak thrombin generation, factor VIII, and soluble CD40 ligand, whereas eosinophil count, peak thrombin generation and antiplasmin predicted t50%.This study is the first to show that EGPA is associated with prothrombotic plasma fibrin clot phenotype, which may contribute to thromboembolic manifestations reported in this disease.

  2. Polymer gel dosimeters with enhanced sensitivity for use in x-ray CT polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria BC V8W 3P6 (Canada); Hilts, M [Medical Physics, BC Cancer Agency-Vancouver Island Centre, Victoria BC V6R 2B6 (Canada); McAuley, K B, E-mail: jirasek@uvic.c [Department of Chemical Engineering, Queens University, Kingston, ON K7 L 3N6 (Canada)

    2010-09-21

    A primary limitation of current x-ray CT polymer gel dosimetry is the low contrast, and hence poor dose resolution, of dose images produced by the system. The low contrast is largely due to the low-dose sensitivity of current formulations of polymer gel for x-ray CT imaging. This study reports on the investigation of new dosimeter formulations with improved dose sensitivity for x-ray CT polymer gel dosimetry. We incorporate an isopropanol co-solvent into an N-isopropylacrylamide-based gel formulation in order to increase the total monomer/crosslinker concentration (%T) within the formulation. It is shown that gels of high %T exhibit enhanced dose sensitivity and dose resolutions over traditional formulations. The gels are shown to be temporally stable and reproducible. A single formulation (16%T) is used to demonstrate the capabilities of the x-ray CT polymer gel dosimetry system in measuring known dose distributions. A 1 L gel volume is exposed to three separate irradiations: a single-field percent depth dose, a two-field 'cross' and a three-field 'test case'. The first two irradiations are used to generate a dose calibration curve by which images are calibrated. The calibrated images are compared with treatment planning predictions and it is shown that the x-ray CT polymer gel dosimetry system is capable of capturing spatial and dose information accurately. The proposed new gel formulation is shown to be sensitive, stable and to improve the dose resolution over current formulations so as to provide a feasible gel for clinical applications of x-ray CT polymer gel dosimetry.

  3. Implementation of MRI gel dosimetry in radiation therapy

    International Nuclear Information System (INIS)

    Baeck, S.Aa.J.

    1998-12-01

    Gel dosimetry was used together with magnetic resonance imaging (MRI) to measure three-dimensional absorbed dose distributions in radiation therapy. Two different dosimeters were studied: ferrous- and monomer gel, based on the principles of radiation-induced oxidation and polymerisation, respectively. Single clinical electron and photon beams were evaluated and gel dose distributions were mainly within 2% of conventional detector results. The ferrous-gel was also used for clinical proton beams. A decrease in signal per absorbed dose was found close to the end of the range of the protons (15-20%). This effect was explained as a linear energy transfer dependence, further supported with Monte Carlo simulations. A method for analysing and comparing data from treatment planning system (TPS) and gel measurements was developed. The method enables a new pixel by pixel evaluation, isodose comparison and dose volume histogram verification. Two standard clinical radiation therapy procedures were examined using the developed TPS verification method. The treatment regimes included several beams of different radiation qualities. The TPS calculated data were in very good agreement with the dose distribution measured by the ferrous-gel. However, in a beam abutment region, larger dose difference was found. Beam adjustment errors and a minor TPS underestimation of the lateral scatter contribution outside the primary electron beam may explain the discrepancy. The overall uncertainty in the ferrous-gel dose determination was considerably reduced using an optimised MRI acquisition protocol and a new MRI scanner. The relative dose uncertainty was found to be better than 3.3% for all dose levels (95% confidence level). Using the method developed for comparing measured gel data with calculated treatment plans, the gel dosimetry method was proven to be a useful tool for radiation treatment planning verification

  4. Implementation of MRI gel dosimetry in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Baeck, S.Aa.J

    1998-12-01

    Gel dosimetry was used together with magnetic resonance imaging (MRI) to measure three-dimensional absorbed dose distributions in radiation therapy. Two different dosimeters were studied: ferrous- and monomer gel, based on the principles of radiation-induced oxidation and polymerisation, respectively. Single clinical electron and photon beams were evaluated and gel dose distributions were mainly within 2% of conventional detector results. The ferrous-gel was also used for clinical proton beams. A decrease in signal per absorbed dose was found close to the end of the range of the protons (15-20%). This effect was explained as a linear energy transfer dependence, further supported with Monte Carlo simulations. A method for analysing and comparing data from treatment planning system (TPS) and gel measurements was developed. The method enables a new pixel by pixel evaluation, isodose comparison and dose volume histogram verification. Two standard clinical radiation therapy procedures were examined using the developed TPS verification method. The treatment regimes included several beams of different radiation qualities. The TPS calculated data were in very good agreement with the dose distribution measured by the ferrous-gel. However, in a beam abutment region, larger dose difference was found. Beam adjustment errors and a minor TPS underestimation of the lateral scatter contribution outside the primary electron beam may explain the discrepancy. The overall uncertainty in the ferrous-gel dose determination was considerably reduced using an optimised MRI acquisition protocol and a new MRI scanner. The relative dose uncertainty was found to be better than 3.3% for all dose levels (95% confidence level). Using the method developed for comparing measured gel data with calculated treatment plans, the gel dosimetry method was proven to be a useful tool for radiation treatment planning verification 103 refs, 20 figs, 6 tabs

  5. A comparative study of the regenerative effect of sinus bone grafting with platelet-rich fibrin-mixed Bio-Oss® and commercial fibrin-mixed Bio-Oss®: an experimental study.

    Science.gov (United States)

    Xuan, Feng; Lee, Chun-Ui; Son, Jeong-Seog; Jeong, Seung-Mi; Choi, Byung-Ho

    2014-06-01

    Anorganic bovine bone (Bio-Oss®) particles are one of the most popular grafting materials. The particles are often mixed with platelet-rich fibrin (PRF) or a commercial fibrin (Tisseel®) to form a mouldable graft material. The objective of this study was to compare the potentials of PRF-mixed Bio-Oss® and Tisseel®-mixed Bio-Oss® to enhance bone regeneration in a canine sinus model. Six mongrel dogs were used in this study. After elevating the sinus membrane in both maxillary sinus cavities, an implant was placed into the sinus cavity. In one of the sinus cavities, the PRF/Bio-Oss® composite was grafted, and the Tisseel®/Bio-Oss® composite was grafted in the other sinus cavity. After a 6 month healing period, bone formation in the graft sites and bone-implant contact were evaluated. The mean osseointegration rate was 43.5 ± 12.4% and new bone formation rate 41.8 ± 5.9% in the PRF/Bio-Oss® composite sites. In the Tisseel®/Bio-Oss® composite sites they were 30.7 ± 7.9% and 31.3 ± 6.4%. There were statistically significant differences between the groups. The findings from this study suggest that when platelet-rich fibrin is used as an adjunct to Bio-Oss® particles for bone augmentation in the maxillary sinus, bone formation in the graft sites is significantly greater than when Tisseel® is used. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  6. Safety and hemostatic efficacy of fibrin pad in partial nephrectomy: Results of an open-label Phase I and a randomized, standard-of-care-controlled Phase I/II study

    Directory of Open Access Journals (Sweden)

    Nativ Ofer

    2012-11-01

    Full Text Available Abstract Background Bleeding severity, anatomic location, tissue characteristics, and visibility are common challenges encountered while managing intraoperative bleeding, and conventional hemostatic measures (suture, ligature, and cautery may sometimes be ineffective or impractical. While topical absorbable hemostats (TAH are useful hemostatic adjuvants, each TAH has associated disadvantages. Methods We evaluated the safety and hemostatic efficacy of a new advanced biologic combination product―fibrin pad―to potentially address some gaps associated with TAHs. Fibrin pad was assessed as adjunctive hemostat in open partial nephrectomy in single-center, open-label, Phase I study (N = 10, and as primary hemostat in multicenter, single-blind, randomized, standard-of-care (SOC-controlled Phase I/II study (N = 7 in Israel. It was used to control mild-to-moderate bleeding in Phase I and also spurting arterial bleeding in Phase I/II study. Phase I study assessed safety and Phase I/II study, proportion of successes at 10 min following randomization, analyzed by Fisher exact tests at 5% significance level. Results Phase I (N = 10: All patients completed the study. Hemostasis was achieved within 3–4 min (average = 3.1 min of a single application in all patients. Fibrin pad was found to be safe for human use, with no product-related adverse events reported. Phase I/II (N = 7: Hemostatic success at 10 min (primary endpoint was achieved in 3/4 patients treated with fibrin pad versus 0/3 patients treated with SOC. No clinically significant change in laboratory or coagulation parameters was recorded, except a case of post-procedural hemorrhage with fibrin pad, which was considered serious and related to the fibrin pad treatment, and required re-operation. Although Data Safety Monitoring Board authorized trial continuation, the sponsor decided against proceeding toward an indication for primary treatment of severe arterial

  7. Preparation of zirconium molybdate gel for 99mTc gel generator

    International Nuclear Information System (INIS)

    Aliludin, Z.; Ohkubo, Masatake; Kushita, Kouhei

    1988-09-01

    Zirconium molybdate gel has excellent characteristics for use as column matrix material of 99m Tc generators. In this work, zirconium molybdate gels were prepared under different conditions; pH's of molybdate solutions from 2.5 to 7.0, Mo:Zr molar ratios from 0.7:1.0 to 1.3:1.0, drying temperatures from an ambient temperature to 200 deg C, and drying times from 1 h to 25 h. Contents of water, nitrate, molybdenum and zirconium were measured to examine the fundamental conditions in gel preparation. The Mo:Zr molar ratio was 1.0:1.0 for the most of gels obtained. A 99m Tc generator was prepared with an amorphous zirconium molybdate containing a tracer level of 99 Mo as column matrix material. Elution of 99m Tc was rapid and the average elution efficiency was 90 % for 6 ml elutions. Contents of radionuclidic impurities, Zr and Mo in the eluates, were low enough to meet the pharmacopoeia requirements for human use. (author)

  8. The effects of dynamic and three-dimensional environments on chondrogenic differentiation of bone marrow stromal cells

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Youngmee; Kim, Sang-Heon; Kim, Soo Hyun [Biomaterials Research Center, Korea Institute of Science and Technology, PO Box 131, Cheonryang, Seoul, 130-650 (Korea, Republic of); Kim, Young Ha, E-mail: soohkim@kist.re.k [Department of Materials Science and Engineering, Gwangju Institute of Science and Technology, 261 Cheomdan-gwagiro, Buk-gu, Gwangju 500-712 (Korea, Republic of)

    2009-10-15

    Articular cartilage is subjected to complex loading, which plays a major role in its growth, development and maintenance. Previously, we found that mechanical stimuli enhanced the development and function of engineered cartilage tissues in elastic mechano-active poly(lactide-co-caprolactone) (PLCL) scaffolds. In addition, it is well known that the three-dimensional spatial organization of cells and extracellular matrices in hydrogels is crucial to chondrogenesis. This study was conducted to enhance the chondrogenic differentiation of bone marrow stromal cells (BMSCs) in the hybrid scaffolds of fibrin gels and PLCL scaffolds in dynamic environments by compression. A highly elastic scaffold was fabricated from very elastic PLCL with 85% porosity and a 300-500{mu}m pore size using a gel-pressing method. A mixture of rabbit BMSCs and fibrin gels was then seeded onto the PLCL scaffolds and subjected to continuous compressive deformation of 5% strain at 0.1 Hz for 10 days in a chondrogenic medium containing 10 ng ml{sup -1} TGF-beta{sub 1}. The BMSCs-seeded scaffold constructs were then implanted subcutaneously into nude mice. As a control, the cell-PLCL scaffold constructs were cultured under dynamic conditions or the cell-PLCL/fibrin hybrid scaffold constructs and the cell-PLCL scaffold constructs were cultured under static conditions for 10 days in vitro. The results revealed that cells adhered onto the hybrid scaffolds of fibrin gels and PLCL scaffolds cultured under dynamic conditions. In addition, the accumulation of the extracellular matrix of cell-scaffold constructs, which was increased through mechanical stimulation, showed that chondrogenic differentiation was sustained and enhanced significantly in the stimulated hybrid scaffold constructs. Overall, the results of this study indicate that the proper periodic application of dynamic compression and the three-dimensional environments of the hybrid scaffolds composed of fibrin gels and elastic PLCL can encourage

  9. Evaluation of the effect of platelet-rich fibrin on the alveolar osteitis ...

    African Journals Online (AJOL)

    Evaluation of the effect of platelet-rich fibrin on the alveolar osteitis incidence and periodontal probing depth after extracting partially erupted mandibular third ... Conclusions: PRF significantly reduced the AO incidence among smokers and had a positive effect on postoperative pain levels but not on periodontal healing.

  10. Radiotherapy gel dosimetry

    International Nuclear Information System (INIS)

    Baldock, C.

    2002-01-01

    shapes and sizes while sparing normal tissue. The situation is further complicated if the normal tissues are critical organs or are particularly sensitive to radiation. Radiotherapy techniques employed to obtain a closer conformation of the dose distribution to the tumour volume are referred to as conformal radiotherapy techniques. The clinical implementation of conformal therapy has been delayed by limitations in the verification of conformal dose distributions calculated by treatment planning systems prior to the irradiation of the patient and the verification of complex treatments during its delivery to the patient. There are several aspects of conformal therapy that complicate dose verification. To achieve the dose distributions conforming to complex 3D volumes, high dose gradients arise in the treatment volume. Further, overdose or underdose regions can exist when separate radiation fields are used to deliver additional radiation. These aspects require that practical dose measurement (dosimetry) techniques be able to integrate dose over time and easily measure dose distributions in 3D with high spatial resolution. Traditional dosimeters, such as ion chambers, thermoluminescent dosimeters and radiographic film do not fulfil these requirements. Novel gel dosimetry techniques are being developed in which dose distributions can potentially be determined in vitro in 3D using anthropomorphic phantoms to simulate a clinically irradiated situation. As long ago as the 1950's, radiation-induced colour change in dyes was used to investigate radiation doses in gels. It was subsequently shown that radiation induced changes in nuclear magnetic resonance (NMR) relaxation properties of gels infused with conventional Fricke dosimetry solutions could be measured using magnetic resonance imaging (MRI). In Fricke gels, Fe 2+ ions in ferrous sulphate solutions are usually dispersed throughout a gelatin, agarose or PVA matrix. Radiation-induced changes in the dosimeters are considered to

  11. Combination of heterologous fibrin sealant and bioengineered human embryonic stem cells to improve regeneration following autogenous sciatic nerve grafting repair.

    Science.gov (United States)

    Mozafari, Roghayeh; Kyrylenko, Sergiy; Castro, Mateus Vidigal; Ferreira, Rui Seabra; Barraviera, Benedito; Oliveira, Alexandre Leite Rodrigues

    2018-01-01

    Peripheral nerve injury is a worldwide clinical problem, and the preferred surgical method for treating it is the end-to-end neurorrhaphy. When it is not possible due to a large nerve gap, autologous nerve grafting is used. However, these surgical techniques result in nerve regeneration at highly variable degrees. It is thus very important to seek complementary techniques to improve motor and sensory recovery. One promising approach could be cell therapy. Transplantation therapy with human embryonic stem cells (hESCs) is appealing because these cells are pluripotent and can differentiate into specialized cell types and have self-renewal ability. Therefore, the main objective of this study was to find conditions under which functional recovery is improved after sciatic nerve neurorrhaphy. We assumed that hESC, either alone or in combination with heterologous fibrin sealant scaffold, could be used to support regeneration in a mouse model of sciatic nerve injury and repair via autografting with end-to-end neurorrhaphy. Five millimeters of the sciatic nerve of C57BL/6 J mice were transected off and rotated 180 degrees to simulate an injury, and then stumps were sutured. Next, we applied heterologous fibrin sealant and/or human embryonic stem cells genetically altered to overexpress fibroblast growth factor 2 (FGF2) at the site of the injury. The study was designed to include six experimental groups comprising neurorrhaphy (N), neurorrhaphy + heterologous fibrin sealant (N + F), neurorrhaphy + heterologous fibrin sealant + doxycycline (N + F + D), neurorrhaphy + heterologous fibrin sealant + wild-type hESC (N + F + W), neurorrhaphy + heterologous fibrin sealant + hESC off (N + F + T), and neurorrhaphy + heterologous fibrin sealant + hESC on via doxycycline (N + F + D + T). We evaluated the recovery rate using Catwalk and von Frey functional recovery tests, as well as immunohistochemistry analysis. The experiments indicated that

  12. Towards a quantitative understanding of oxygen tension and cell density evolution in fibrin hydrogels.

    Science.gov (United States)

    Demol, Jan; Lambrechts, Dennis; Geris, Liesbet; Schrooten, Jan; Van Oosterwyck, Hans

    2011-01-01

    The in vitro culture of hydrogel-based constructs above a critical size is accompanied by problems of unequal cell distribution when diffusion is the primary mode of oxygen transfer. In this study, an experimentally-informed mathematical model was developed to relate cell proliferation and death inside fibrin hydrogels to the local oxygen tension in a quantitative manner. The predictive capacity of the resulting model was tested by comparing its outcomes to the density, distribution and viability of human periosteum derived cells (hPDCs) that were cultured inside fibrin hydrogels in vitro. The model was able to reproduce important experimental findings, such as the formation of a multilayered cell sheet at the hydrogel periphery and the occurrence of a cell density gradient throughout the hydrogel. In addition, the model demonstrated that cell culture in fibrin hydrogels can lead to complete anoxia in the centre of the hydrogel for realistic values of oxygen diffusion and consumption. A sensitivity analysis also identified these two parameters, together with the proliferation parameters of the encapsulated cells, as the governing parameters for the occurrence of anoxia. In conclusion, this study indicates that mathematical models can help to better understand oxygen transport limitations and its influence on cell behaviour during the in vitro culture of cell-seeded hydrogels. Copyright © 2010 Elsevier Ltd. All rights reserved.

  13. Fibrinous anterior uveitis following laser in situ keratomileusis

    Directory of Open Access Journals (Sweden)

    Parmar Pragya

    2009-01-01

    Full Text Available A 29-year-old woman who underwent laser in situ keratomileusis (LASIK for myopic astigmatism in both eyes presented with severe pain, photophobia and decreased visual acuity in the left eye eight days after surgery. Examination revealed severe anterior uveitis with fibrinous exudates in the anterior chamber, flap edema and epithelial bullae. Laboratory investigations for uveitis were negative and the patient required systemic and intensive topical steroids with cycloplegics to control the inflammation. This case demonstrates that severe anterior uveitis may develop after LASIK and needs prompt and vigorous management for resolution.

  14. Improving calibration accuracy in gel dosimetry

    International Nuclear Information System (INIS)

    Oldham, M.; McJury, M.; Webb, S.; Baustert, I.B.; Leach, M.O.

    1998-01-01

    A new method of calibrating gel dosimeters (applicable to both Fricke and polyacrylamide gels) is presented which has intrinsically higher accuracy than current methods, and requires less gel. Two test-tubes of gel (inner diameter 2.5 cm, length 20 cm) are irradiated separately with a 10x10cm 2 field end-on in a water bath, such that the characteristic depth-dose curve is recorded in the gel. The calibration is then determined by fitting the depth-dose measured in water, against the measured change in relaxivity with depth in the gel. Increased accuracy is achieved in this simple depth-dose geometry by averaging the relaxivity at each depth. A large number of calibration data points, each with relatively high accuracy, are obtained. Calibration data over the full range of dose (1.6-10 Gy) is obtained by irradiating one test-tube to 10 Gy at dose maximum (D max ), and the other to 4.5 Gy at D max . The new calibration method is compared with a 'standard method' where five identical test-tubes of gel were irradiated to different known doses between 2 and 10 Gy. The percentage uncertainties in the slope and intercept of the calibration fit are found to be lower with the new method by a factor of about 4 and 10 respectively, when compared with the standard method and with published values. The gel was found to respond linearly within the error bars up to doses of 7 Gy, with a slope of 0.233±0.001 s -1 Gy -1 and an intercept of 1.106±0.005 Gy. For higher doses, nonlinear behaviour was observed. (author)

  15. Multisite Thrombus Imaging and Fibrin Content Estimation With a Single Whole-Body PET Scan in Rats.

    Science.gov (United States)

    Blasi, Francesco; Oliveira, Bruno L; Rietz, Tyson A; Rotile, Nicholas J; Naha, Pratap C; Cormode, David P; Izquierdo-Garcia, David; Catana, Ciprian; Caravan, Peter

    2015-10-01

    Thrombosis is a leading cause of morbidity and mortality worldwide. Current diagnostic strategies rely on imaging modalities that are specific for distinct vascular territories, but a thrombus-specific whole-body imaging approach is still missing. Moreover, imaging techniques to assess thrombus composition are underdeveloped, although therapeutic strategies may benefit from such technology. Therefore, our goal was to test whether positron emission tomography (PET) with the fibrin-binding probe (64)Cu-FBP8 allows multisite thrombus detection and fibrin content estimation. Thrombosis was induced in Sprague-Dawley rats (n=32) by ferric chloride application on both carotid artery and femoral vein. (64)Cu-FBP8-PET/CT imaging was performed 1, 3, or 7 days after thrombosis to detect thrombus location and to evaluate age-dependent changes in target uptake. Ex vivo biodistribution, autoradiography, and histopathology were performed to validate imaging results. Arterial and venous thrombi were localized on fused PET/CT images with high accuracy (97.6%; 95% confidence interval, 92-100). A single whole-body PET/MR imaging session was sufficient to reveal the location of both arterial and venous thrombi after (64)Cu-FBP8 administration. PET imaging showed that probe uptake was greater in younger clots than in older ones for both arterial and venous thrombosis (P<0.0001). Quantitative histopathology revealed an age-dependent reduction of thrombus fibrin content (P<0.001), consistent with PET results. Biodistribution and autoradiography further confirmed the imaging findings. We demonstrated that (64)Cu-FBP8-PET is a feasible approach for whole-body thrombus detection and that molecular imaging of fibrin can provide, noninvasively, insight into clot composition. © 2015 American Heart Association, Inc.

  16. Fiber based optical tweezers for simultaneous in situ force exertion and measurements in a 3D polyacrylamide gel compartment.

    Science.gov (United States)

    Ti, Chaoyang; Thomas, Gawain M; Ren, Yundong; Zhang, Rui; Wen, Qi; Liu, Yuxiang

    2015-07-01

    Optical tweezers play an important role in biological applications. However, it is difficult for traditional optical tweezers based on objective lenses to work in a three-dimensional (3D) solid far away from the substrate. In this work, we develop a fiber based optical trapping system, namely inclined dual fiber optical tweezers, that can simultaneously apply and measure forces both in water and in a 3D polyacrylamide gel matrix. In addition, we demonstrate in situ, non-invasive characterization of local mechanical properties of polyacrylamide gel by measurements on an embedded bead. The fiber optical tweezers measurements agree well with those of atomic force microscopy (AFM). The inclined dual fiber optical tweezers provide a promising and versatile tool for cell mechanics study in 3D environments.

  17. Conducting polymer electrodes for gel electrophoresis.

    Directory of Open Access Journals (Sweden)

    Katarina Bengtsson

    Full Text Available In nearly all cases, electrophoresis in gels is driven via the electrolysis of water at the electrodes, where the process consumes water and produces electrochemical by-products. We have previously demonstrated that π-conjugated polymers such as poly(3,4-ethylenedioxythiophene (PEDOT can be placed between traditional metal electrodes and an electrolyte to mitigate electrolysis in liquid (capillary electroosmosis/electrophoresis systems. In this report, we extend our previous result to gel electrophoresis, and show that electrodes containing PEDOT can be used with a commercial polyacrylamide gel electrophoresis system with minimal impact to the resulting gel image or the ionic transport measured during a separation.

  18. Conducting polymer electrodes for gel electrophoresis.

    Science.gov (United States)

    Bengtsson, Katarina; Nilsson, Sara; Robinson, Nathaniel D

    2014-01-01

    In nearly all cases, electrophoresis in gels is driven via the electrolysis of water at the electrodes, where the process consumes water and produces electrochemical by-products. We have previously demonstrated that π-conjugated polymers such as poly(3,4-ethylenedioxythiophene) (PEDOT) can be placed between traditional metal electrodes and an electrolyte to mitigate electrolysis in liquid (capillary electroosmosis/electrophoresis) systems. In this report, we extend our previous result to gel electrophoresis, and show that electrodes containing PEDOT can be used with a commercial polyacrylamide gel electrophoresis system with minimal impact to the resulting gel image or the ionic transport measured during a separation.

  19. Binding of Thrombin-Activated Platelets to a Fibrin Scaffold through ?IIb?3 Evokes Phosphatidylserine Exposure on Their Cell Surface

    OpenAIRE

    Brzoska, Tomasz; Suzuki, Yuko; Mogami, Hideo; Sano, Hideto; Urano, Tetsumei

    2013-01-01

    Recently, by employing intra-vital confocal microscopy, we demonstrated that platelets expose phosphatidylserine (PS) and fibrin accumulate only in the center of the thrombus but not in its periphery. To address the question how exposure of platelet anionic phospholipids is regulated within the thrombus, an in-vitro experiment using diluted platelet-rich plasma was employed, in which the fibrin network was formed in the presence of platelets, and PS exposure on the platelet surface was analyz...

  20. Dual function of a bee venom serine protease: prophenoloxidase-activating factor in arthropods and fibrin(ogen)olytic enzyme in mammals.

    Science.gov (United States)

    Choo, Young Moo; Lee, Kwang Sik; Yoon, Hyung Joo; Kim, Bo Yeon; Sohn, Mi Ri; Roh, Jong Yul; Je, Yeon Ho; Kim, Nam Jung; Kim, Iksoo; Woo, Soo Dong; Sohn, Hung Dae; Jin, Byung Rae

    2010-05-03

    Bee venom contains a variety of peptides and enzymes, including serine proteases. While the presence of serine proteases in bee venom has been demonstrated, the role of these proteins in bee venom has not been elucidated. Furthermore, there is currently no information available regarding the melanization response or the fibrin(ogen)olytic activity of bee venom serine protease, and the molecular mechanism of its action remains unknown. Here we show that bee venom serine protease (Bi-VSP) is a multifunctional enzyme. In insects, Bi-VSP acts as an arthropod prophenoloxidase (proPO)-activating factor (PPAF), thereby triggering the phenoloxidase (PO) cascade. Bi-VSP injected through the stinger induces a lethal melanization response in target insects by modulating the innate immune response. In mammals, Bi-VSP acts similarly to snake venom serine protease, which exhibits fibrin(ogen)olytic activity. Bi-VSP activates prothrombin and directly degrades fibrinogen into fibrin degradation products, defining roles for Bi-VSP as a prothrombin activator, a thrombin-like protease, and a plasmin-like protease. These findings provide a novel view of the mechanism of bee venom in which the bee venom serine protease kills target insects via a melanization strategy and exhibits fibrin(ogen)olytic activity.

  1. Electrical conductivity measurements on gel grown KDP crystals ...

    Indian Academy of Sciences (India)

    Impurity added KDP crystals; gel method; electrical conductivity; activation energy. 1. Introduction. Potassium dihydrogen ... phate [(NH4)2SO4] along with double distilled water and ethyl alcohol were used. KDP was added with .... in the vicinity of electrodes or chemical changes in layers close to electrodes (Bunget and ...

  2. Effectiveness of Fibrin Sealant Patch in Reducing Drain Volume after Pelvic Lymph Node Dissection in Women with Gynecologic Malignancy

    Directory of Open Access Journals (Sweden)

    Hwa Cheong Kim

    2017-01-01

    Full Text Available Background. The goal of this study was to evaluate the effectiveness of fibrin sealant in decreasing postoperative lymphatic drainage in women after pelvic lymphadenectomy and/or para-aortic lymphadenectomy during gynecologic cancer surgery. Methods. This study is a retrospective case-control study. Forty-five patients who underwent staging surgery were enrolled. Twenty-seven patients were in the fibrin sealant group (group A and 18 in the control group (group B. The two groups were compared for the total volume of drain, hospital stay, harvested lymph node, and incidence of asymptomatic lymphocele. Lymphocele formation was evaluated by computed tomography (CT on 3 months after surgery. Results. There were no significant differences in patient demographics between group A and B with respect to age, BMI, and harvested lymph nodes. Patients who received fibrin sealants had reduced total volume of drainage from postoperative days 2 to 5 compared to the control group (group A versus group B: 994.819±745.85 ml versus 1847.89±1241.41 ml; P=0.015. However no differences were observed in hospital stay (P=0.282, duration of drain (P=0.207, and incidence of asymptomatic lymphocele at 3 months (P=0.126. Conclusion. The results of this study indicate that the application of fibrin sealants after pelvic and/or para-aortic lymphadenectomy may reduce lymphatic drainage in gynecologic malignancy.

  3. Physical and chemical properties of gels. Application to protein nucleation control in the gel acupuncture technique

    Science.gov (United States)

    Moreno, Abel; Juárez-Martínez, Gabriela; Hernández-Pérez, Tomás; Batina, Nikola; Mundo, Manuel; McPherson, Alexander

    1999-09-01

    In this work, we present a new approach using analytical and optical techniques in order to determine the physical and chemical properties of silica gel, as well as the measurement of the pore size in the network of the gel by scanning electron microscopy. The gel acupuncture technique developed by García-Ruiz et al. (Mater. Res. Bull 28 (1993) 541) García-Ruiz and Moreno (Acta Crystallogr. D 50 (1994) 484) was used throughout the history of crystal growth. Several experiments were done in order to evaluate the nucleation control of model proteins (thaumatin I from Thaumatococcus daniellii, lysozyme from hen egg white and catalase from bovine liver) by the porous network of the gel. Finally, it is shown how the number and the size of the crystals obtained inside X-ray capillaries is controlled by the size of the porous structure of the gel.

  4. Comparison effect of azithromycin gel 2% with clindamycin gel 1% in patients with acne.

    Science.gov (United States)

    Mokhtari, Fatemeh; Faghihi, Gita; Basiri, Akram; Farhadi, Sadaf; Nilforoushzadeh, Mohammadali; Behfar, Shadi

    2016-01-01

    Acne vulgaris is the most common skin disease. Local and systemic antimicrobial drugs are used for its treatment. But increasing resistance of Propionibacterium acnes to antibiotics has been reported. In a double-blind clinical trial, 40 patients with mild to moderate acne vulgaris were recruited. one side of the face was treated with Clindamycin Gel 1% and the other side with Azithromycin Topical Gel 2% BID for 8 weeks and then they were assessed. Average age was 21. 8 ± 7 years. 82.5% of them were female. Average number of papules, pustules and comedones was similarly reduced in both groups and, no significant difference was observed between the two groups (P > 0.05, repeated measurs ANOVA). The mean indexes of ASI and TLC also significantly decreased during treatment in both groups, no significant difference was observed between the two groups. (P > 0.05, repeated measurs ANOVA). Also, impact of both drugs on papules and pustules was 2-3 times greater than the effect on comedones. Average satisfaction score was not significant between the two groups (P = 0.6, repeated measurs ANOVA). finally, frequency distribution of complications was not significant between the two groups (P > 0.05, Fisher Exact test). Azithromycin gel has medical impact at least similar to Clindamycin Gel in treatment of mild to moderate acne vulgaris, and it may be consider as suitable drug for resistant acne to conventional topical therapy.

  5. No difference in sexual dysfunction after transabdominal preperitoneal (TAPP) approach for inguinal hernia with fibrin sealant or tacks for mesh fixation

    DEFF Research Database (Denmark)

    Pommergaard, H C; Burcharth, J; Andresen, K

    2017-01-01

    BACKGROUND: Postoperative sexual dysfunction in relation to laparoscopic groin hernia surgery may be related to methods of mesh fixation. However, this has not been investigated earlier. Moreover, results regarding sexual dysfunction in females have not been reported systematically. The aim...... of this study was to compare fibrin sealant versus tacks for fixation of mesh regarding sexual dysfunction in males and females. METHODS: Using the Danish Hernia Database, patients operated laparoscopically for groin hernia with a transabdominal preperitoneal (TAPP) procedure with fibrin sealant or tacks...... for mesh fixation were sent a questionnaire regarding sexual dysfunction. Sexually active patients without recurrence were evaluated in this study. RESULTS: Pain during sexual activity was present in 115 of 1019 (11.3 %) males and 17 of 147 (11.6 %) females. There was no difference between fibrin sealant...

  6. The conversion of fibrinogen to fibrin: A brief history of some key events.

    Science.gov (United States)

    Doolittle, Russell F

    2017-07-01

    The conversion of fibrinogen to fibrin is a process that has long fascinated an army of researchers. In this brief review some early break-through observations are noted and a few later unexpected results described. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. In vivo near infrared (NIRS) sensor attachment using fibrin bioadhesive

    Science.gov (United States)

    Macnab, Andrew; Pagano, Roberto; Kwon, Brian; Dumont, Guy; Shadgan, Babak

    2018-02-01

    Background: `Tisseel' (Baxter Healthcare, Deerfield, IL) is a fibrin-based sealant that is commonly used during spine surgery to augment dural repairs. We wish to intra-operatively secure a near infrared spectroscopy (NIRS) sensor to the dura in order to monitor the tissue hemodynamics of the underlying spinal cord. To determine if `Tisseel' sealant adversely attenuates NIR photon transmission. Methods: We investigated `Tisseel' in both an in vitro and in vivo paradigm. For in vitro testing, we used a 1 mm pathlength cuvette containing either air or `Tisseel' interposed between a NIR light source (760 and 850 nm) and a photodiode detector and compared transmittance. For in vivo testing, a continuous wave (760 and 850 nm) spatiallyresolved NIRS device was placed over the triceps muscle using either conventional skin apposition (overlying adhesive bandage) or bioadhesion with `Tisseel'. Raw optical data and tissue saturation index (TSI%) collected at rest were compared. Results: In-vitro NIR light absorption by `Tisseel' was very high, with transmittance reduced by 95% compared to air. In-vivo muscle TSI% values were 80% with conventional attachment and 20% using fibrin glue. Conclusion: The optical properties of `Tisseel' significantly attenuate NIR light during in-vitro transmittance and critically compromise photon transmission in-vivo.

  8. Platelet-Rich Fibrin Accelerates Skin Wound Healing in Diabetic Mice.

    Science.gov (United States)

    Ding, Yinjia; Cui, Lei; Zhao, Qiming; Zhang, Weiqiang; Sun, Huafeng; Zheng, Lijun

    2017-09-01

    Diabetic foot ulcers (DFUs) are associated with an increased risk of secondary infection and amputation. Platelet-rich fibrin (PRF), a platelet and leukocyte concentrate containing several cytokines and growth factors, is known to promote wound healing. However, the effect of PRF on diabetic wound healing has not been adequately investigated. The aim of the study was to investigate the effect of PRF on skin wound healing in a diabetic mouse model. Platelet-rich fibrin was prepared from whole blood of 8 healthy volunteers. Two symmetrical skin wounds per mouse were created on the back of 16 diabetic nude mice. One of the 2 wounds in each mouse was treated with routine dressings (control), whereas the other wound was treated with PRF in addition to routine dressings (test), each for a period of 14 days. Skin wound healing rate was calculated.Use of PRF was associated with significantly improved skin wound healing in diabetic mice. On hematoxylin and eosin and CD31 staining, a significant increase in the number of capillaries and CD31-positive cells was observed, suggesting that PRF may have promoted blood vessel formation in the skin wound. In this study, PRF seemed to accelerate skin wound healing in diabetic mouse models, probably via increased blood vessel formation.

  9. Transdermal delivery of paeonol using cubic gel and microemulsion gel

    Science.gov (United States)

    Luo, Maofu; Shen, Qi; Chen, Jinjin

    2011-01-01

    Background The aim of this study was to develop new systems for transdermal delivery of paeonol, in particular microemulsion gel and cubic gel formulations. Methods Various microemulsion vehicles were prepared using isopropyl myristate as an oil phase, polyoxyethylated castor oil (Cremophor® EL) as a surfactant, and polyethylene glycol 400 as a cosurfactant. In the optimum microemulsion gel formulation, carbomer 940 was selected as the gel matrix, and consisted of 1% paeonol, 4% isopropyl myristate, 28% Cremophor EL/polyethylene glycol 400 (1:1), and 67% water. The cubic gel was prepared containing 3% paeonol, 30% water, and 67% glyceryl monooleate. Results A skin permeability test using excised rat skins indicated that both the cubic gel and microemulsion gel formulations had higher permeability than did the paeonol solution. An in vivo pharmacokinetic study done in rats showed that the relative bioavailability of the cubic gel and microemulsion gel was enhanced by about 1.51-fold and 1.28-fold, respectively, compared with orally administered paeonol suspension. Conclusion Both the cubic gel and microemulsion gel formulations are promising delivery systems to enhance the skin permeability of paeonol, in particular the cubic gel. PMID:21904450

  10. Effect of topical autologous platelet-rich fibrin versus no intervention on epithelialization of donor sites and meshed split-thickness skin autografts: a randomized clinical trial

    DEFF Research Database (Denmark)

    Danielsen, P.; Jorgensen, B.; Jorgensen, L.N.

    2008-01-01

    BACKGROUND: Autologous platelet-rich fibrin contains multiple growth factors. The aim of this randomized clinical trial was to study the effect of topical platelet-rich fibrin on epithelialization of donor sites and meshed split-thickness skin autografts. METHODS: Twenty consecutive leg ulcer pat...

  11. Examining platelet-fibrin interactions during traumatic shock in a swine model using platelet contractile force and clot elastic modulus.

    Science.gov (United States)

    White, Nathan J; Martin, Erika J; Brophy, Donald F; Ward, Kevin R

    2011-07-01

    A significant proportion of severely injured patients develop early coagulopathy, characterized by abnormal clot formation, which impairs resuscitation and increases mortality. We have previously demonstrated an isolated decrease in clot strength by thrombelastography in a swine model of nonresuscitated traumatic shock. In order to more closely examine platelet-fibrin interactions in this setting, we define the observed decrease in clot strength in terms of platelet-induced clot contraction and clot elastic modulus using the Hemostasis Analysis System (HAS) (Hemodyne Inc., Richmond, Virginia, USA). Whole blood was sampled for HAS measurements, metabolic measurements, cell counts, and fibrinogen concentration at baseline prior to injury and again at a predetermined level of traumatic shock defined by oxygen debt. Male swine (N=17) received femur fracture and controlled arterial hemorrhage to achieve an oxygen debt of 80 ml/kg. Platelet counts were unchanged, but fibrinogen concentration was reduced significantly during shock (167.6 vs. 66.7 mg/dl, P=0.0007). Platelet contractile force generated during clot formation did not change during shock (11.7 vs. 10.4 kdynes, P=0.41), but clot elastic modulus was dynamically altered, resulting in a lower final value (22.9 vs. 17.3 kdynes/cm, Pshock, platelet function was preserved, whereas terminal clot elastic modulus was reduced during shock in a manner most consistent with early changes in the mechanical properties of the developing fibrin fiber network.

  12. Hematopoietic stem cell cytokines and fibroblast growth factor-2 stimulate human endothelial cell-pericyte tube co-assembly in 3D fibrin matrices under serum-free defined conditions.

    Directory of Open Access Journals (Sweden)

    Annie O Smith

    Full Text Available We describe a novel 3D fibrin matrix model using recombinant hematopoietic stem cell cytokines under serum-free defined conditions which promotes the assembly of human endothelial cell (EC tubes with co-associated pericytes. Individual ECs and pericytes are randomly mixed together and EC tubes form that is accompanied by pericyte recruitment to the EC tube abluminal surface over a 3-5 day period. These morphogenic processes are stimulated by a combination of the hematopoietic stem cell cytokines, stem cell factor, interleukin-3, stromal derived factor-1α, and Flt-3 ligand which are added in conjunction with fibroblast growth factor (FGF-2 into the fibrin matrix. In contrast, this tube morphogenic response does not occur under serum-free defined conditions when VEGF and FGF-2 are added together in the fibrin matrices. We recently demonstrated that VEGF and FGF-2 are able to prime EC tube morphogenic responses (i.e. added overnight prior to the morphogenic assay to hematopoietic stem cell cytokines in collagen matrices and, interestingly, they also prime EC tube morphogenesis in 3D fibrin matrices. EC-pericyte interactions in 3D fibrin matrices leads to marked vascular basement membrane assembly as demonstrated using immunofluorescence and transmission electron microscopy. Furthermore, we show that hematopoietic stem cell cytokines and pericytes stimulate EC sprouting in fibrin matrices in a manner dependent on the α5β1 integrin. This novel co-culture system, under serum-free defined conditions, allows for a molecular analysis of EC tube assembly, pericyte recruitment and maturation events in a critical ECM environment (i.e. fibrin matrices that regulates angiogenic events in postnatal life.

  13. Intraoperative use of fibrin glue dyed with methylene blue in surgery for branchial cleft anomalies.

    Science.gov (United States)

    Piccioni, Michela; Bottazzoli, Marco; Nassif, Nader; Stefini, Stefania; Nicolai, Piero

    2016-09-01

    We present a new method of optimizing the results of surgery for branchial cleft anomalies based on the intraoperative injection of fibrin glue combined with methylene blue dye. Retrospective single-center cohort study. The method was applied in 17 patients suffering from branchial anomalies. Six (35.29%) had a preauricular lesion; three (17.65%) had lesions derived from the first arch/pouch/groove (type I), four (23.53%) had lesions derived from the first (type II), one (5.88%) had lesions derived from the second, one (5.88%) had lesions derived from the third, and two (11.76%) had lesions derived from the fourth. The median and mean age at surgery were 10 and 10.6 years, respectively. All patients were followed by periodic clinical and ultrasonographic examination. The combination of fibrin glue with methylene blue facilitated the correct assessment of the extension of the lesions and their intraoperative manipulation. After a mean follow-up of 47.8 months, all patients were free of disease. Intraoperative injection of branchial fistulae and cysts by a mixture of fibrin glue and methylene blue is an effective, easy, and safe tool to track lesions and achieve radical resection. The technique requires a definitive validation on a large cohort with adequate stratification of patients. 4 Laryngoscope, 126:2147-2150, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  14. Silica scintillating materials prepared by sol-gel methods

    International Nuclear Information System (INIS)

    Werst, D.W.; Sauer, M.C. Jr.; Cromack, K.R.; Lin, Y.; Tartakovsky, E.A.; Trifunac, A.D.

    1993-01-01

    Silica was investigated as a rad-hard alternative to organic polymer hosts for organic scintillators. Silica sol-gels were prepared by hydrolysis of tetramethoxysilane in alcohol solutions. organic dyes were incorporated into the gels by dissolving in methanol at the sol stage of gel formation. The silica sol-gel matrix is very rad-hard. The radiation stability of silica scintillators prepared by this method is dye-limited. Transient radioluminescence was measured following excitation with 30 ps pulses of 20 MeV electrons

  15. High-throughput proteomic characterization of plasma rich in growth factors (PRGF-Endoret)-derived fibrin clot interactome.

    Science.gov (United States)

    Anitua, Eduardo; Prado, Roberto; Azkargorta, Mikel; Rodriguez-Suárez, Eva; Iloro, Ibon; Casado-Vela, Juan; Elortza, Felix; Orive, Gorka

    2015-11-01

    Plasma rich in growth factors (PRGF®-Endoret®) is an autologous technology that contains a set of proteins specifically addressed to wound healing and tissue regeneration. The scaffold formed by using this technology is a clot mainly composed of fibrin protein, forming a three-dimensional (3D) macroscopic network. This biomaterial is easily obtained by biotechnological means from blood and can be used in a range of situations to help wound healing and tissue regeneration. Although the main constituent of this clot is the fibrin scaffold, little is known about other proteins interacting in this clot that may act as adjuvants in the healing process. The aim of this study was to characterize the proteins enclosed by PRGF-Endoret scaffold, using a double-proteomic approach that combines 1D-SDS-PAGE approach followed by LC-MS/MS, and 2-DE followed by MALDI-TOF/TOF. The results presented here provide a description of the catalogue of key proteins in close contact with the fibrin scaffold. The obtained lists of proteins were grouped into families and networks according to gene ontology. Taken together, an enrichment of both proteins and protein families specifically involved in tissue regeneration and wound healing has been found. Copyright © 2013 John Wiley & Sons, Ltd.

  16. Synthesis of a cyclic fibrin-like peptide and its analysis by fast atom bombardment mass spectrometry

    International Nuclear Information System (INIS)

    Young, J.D.; Costello, C.E.; Langenhove, A. van; Haber, E.; Matsueda, G.R.

    1983-01-01

    For immunochemical purposes, a cyclic 12 peptide was synthesized to model the γ-γ-chain cross-link site in human fibrin. The model was based upon the structure proposed by Chen and Doolittle which is characterized by two reciprocating epsilon-(γ-Glu)Lys bonds between adjacent fibrin γ-chains oriented in an antiparallel manner. To achieve the antiparallel orientation of the peptide backbone, Pro and Gly were inserted at positions 6 and 7 of the linear 12-peptide: acetyl-Gly-Glu-Gln-His-His-Pro-Gly-Gly-Gly-Ala-Lys-Gly-amide. The insertions were made to facilitate a reverse turn of the peptide during the last synthetic step, which was formation of the epsilon-(γ-Glu)Lys bond between Glu at position 2 and Lys at position 11 with diphenylphosphorylazide. The resulting cyclic peptide represented half of the symmetrical cross-linked region in clotted fibrin. Following purification by HPLC, both linear and cyclic 12-peptides were analyzed by fast atom bombardment mass spectrometry. Abundant molecular protonated ions were observed for both peptides. In addition, the amino acid sequence of the linear peptide and the location of the epsilon-(γ-Glu)Lys bond in the cyclized peptide could be verified. (author)

  17. Percutaneous sclerotherapy of sialoceles after parotidectomy with fibrin glue, OK-432, and bleomycin.

    Science.gov (United States)

    Chen, Wei-liang; Zhang, Li-ping; Huang, Zhi-quan; Zhou, Bin

    2013-12-01

    We evaluated the curative effect of fibrin glue combined with OK-432 (streptococcal pyrogenic exotoxin A, Picibanil™) and bleomycin on 9 patients with sialoceles after parotidectomy. The primary lesions included pleomorphic adenomas in 6 cases and Warthin's tumours in 3 cases. After a sialocele had been diagnosed each patient had repeated aspirations and pressure dressings for 3-4 weeks, but these treatments failed. The patients were then treated with percutaneous sclerotherapy with the injection of fibrin glue 8-10 ml combined with OK-432 5 mg and bleomycin 15 mg. All the sialoceles disappeared completely after a single procedure in 2-3 weeks. The patients have been followed up for more than 6 months with no evidence of recurrent sialocele or injury to the facial nerve related to sclerotherapy. This simple, safe technique can be successfully used to treat sialoceles after parotidectomy. Copyright © 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Mice plasma fibrinogen consumption by thrombin-like enzyme present in rattlesnake venom from the North-East region of Argentina Consumo de fibrinógeno plasmático en ratones por acción de enzima con actividad trombínica presente en el veneno de cascabel del nordeste argentino

    Directory of Open Access Journals (Sweden)

    Silvana L. Maruñak

    2004-12-01

    Full Text Available Due to variability of venom components from the same species of snakes that inhabit different regions, particular properties of the venom of Crotalus durissus terrificus that inhabits the North-East of Argentina were studied. Gyroxin, a thrombin-like enzyme, was isolated from this venom by gel filtration and affinity chromatography, it was found to be homogeneous according to SDS-PAGE, with a molecular weight of 33 kDa. "Gyroxin syndrome" in mice was tested and it showed changes in the animal behavior, confirming that the isolated thrombin-like enzyme is gyroxin. Effects of this enzyme and the crude venom on mice plasmatic fibrinogen levels were determined. The mice plasma fibrinogen decreased rapidly until incoagulability during the first hour after thrombin-Iike enzyme injection, then reaching its normal level 10 hours after injection; whereas crude venom resulted in a 60% decrease of the mice plasma fibrinogen, reaching its normal level after the same period of time. After 1 hour of gyroxin inoculation, intravascular coagulation was observed in histological cuttings of lung, cardiac muscle and liver. The isolated enzyme showed strong hydrolyzing activity on fibrinogen and fibrin in vitro, whereas the crude venom exhibited weak hydrolyzing activity on both substrates. It is probable that this very low activity is due to the low percentage of the enzyme in the crude venom. Decreasing of plasmatic fibrinogen levels may be due to either the coagulant or hydrolyzing actions of the enzyme.Teniendo en cuenta la variabilidad de los componentes del veneno de serpientes de una misma especie que habitan regiones diferentes, se decidió estudiar las propiedades particulares del veneno de Crotalus durissus terrificus que habita el nordeste de Argentina, Giroxina, una enzima con actividad trombínica, fue aislada del veneno por cromatografía de filtración por gel y de afinidad; se comprobó su homogeneidad y se determinó su peso molecular, 33 kDa, por

  19. Fluoride Rinses, Gels and Foams

    DEFF Research Database (Denmark)

    Twetman, Svante; Keller, Mette K

    2016-01-01

    AIM: The aim of this conference paper was to systematically review the quality of evidence and summarize the findings of clinical trials published after 2002 using fluoride mouth rinses, fluoride gels or foams for the prevention of dental caries. METHODS: Relevant papers were selected after...... (6 on fluoride mouth rinse, 10 on fluoride gel and 3 on fluoride foam); 6 had a low risk of bias while 2 had a moderate risk. All fluoride measures appeared to be beneficial in preventing crown caries and reversing root caries, but the quality of evidence was graded as low for fluoride mouth rinse......, moderate for fluoride gel and very low for acidulated fluoride foam. No conclusions could be drawn on the cost-effectiveness. CONCLUSIONS: This review, covering the recent decade, has further substantiated the evidence for a caries-preventive effect of fluoride mouth rinse, fluoride gel and foam...

  20. Organization versus frustration: low temperature transitions in a gelatine-based gel

    Energy Technology Data Exchange (ETDEWEB)

    Philipp, M; Mueller, U; Sanctuary, R; Baller, J; Krueger, J K [Laboratoire de Physique des Materiaux, Universite du Luxembourg, 162A, avenue de la Faiencerie, L-1511 (Luxembourg)], E-mail: martine.philipp@uni.lu

    2008-09-15

    A commercial physical gel composed of gelatine, water and glycerol shows a sol-gel transition which has been resolved by optical rotation measurements by step-wise heating the gel. This transition is not observable in the longitudinal acoustic mode measured at hypersonic frequencies with Brillouin spectroscopy. Depending on the thermal treatment of the investigated material during the sol-gel transition and within the gel state, Brillouin spectroscopy reflects tremendously different hypersonic dynamics. These distinct dynamics are responsible for the formation of different glassy states at low temperatures including that of a glass-ceramic. The large variety of super-cooled and glassy states is attributed to distinct distributions of the gel's constituents within the samples. Surprisingly, the same gel state can be produced either by annealing the gel over months or by the non-equilibrium effect of thermo-diffusion (Soret effect) in the course of some minutes.

  1. Laparoendoscopic single-site myomectomy and the use of fibrin sealant (Tisseel

    Directory of Open Access Journals (Sweden)

    Angelito Magno

    2015-11-01

    Full Text Available Myomectomy remains the standard surgical treatment for women with uterine myoma, who wish to preserve their fertility. However, it is often associated with increased blood loss and adhesion formation. Laparoscopic myomectomy has multiple advantages over open myomectomy1. A newer approach, laparoendoscopic single-site surgery, also known as LESS, has been developed and applied in gynecologic field.2 This is a case of a 41-year-old G2P1 patient, with the complaints of irregular menstrual cycles and lower abdominal pain for 6 months. Transvaginal ultrasound showed uterine myoma at the anterior corpus, measuring 6 × 5 cm2. The procedure is started by grasping the bilateral edges of the umbilicus with Allis forceps. A vertical incision, 1.5–2 cm, is made from the superficial skin of the umbilicus to the ventral peritoneum. A wound retractor of appropriate size is inserted and adjusted. A multiple instrument access port (LagisEndosurgical, Taichung, Taiwan is placed over the wound retractor (Figure 1. Prior to the procedure, inspection of the pelvic organs is performed to determine the pathology. Vasopressin is injected over the area of the myoma to decrease blood loss. Location of the myoma is then identified. Uterine incision is made on the serosa over the area of the myoma using the monopolar scissors. Using a bipolar instrument LigaSure®, ValleyLab, Inc., Boulder, Colorado, the incision is extended until the myoma is exposed. The myoma is grasped gently using the tenaculum forcep, and dissected bluntly along with it's pseudocapsule using the tip of suction irrigation gear. At the base of the myoma where feeding vessels may be located, coagulation by the advanced bipolar, is performed to prevent bleeding. The specimen is removed through the umbilicus. A sliding knot is made at the tail of one zero monofilament suture to fasten the anchor of the first knot. The uterus is then repaired with a continuous non-locking method. Hemostasis is

  2. Motor recovery and synaptic preservation after ventral root avulsion and repair with a fibrin sealant derived from snake venom.

    Directory of Open Access Journals (Sweden)

    Roberta Barbizan

    Full Text Available BACKGROUND: Ventral root avulsion is an experimental model of proximal axonal injury at the central/peripheral nervous system interface that results in paralysis and poor clinical outcome after restorative surgery. Root reimplantation may decrease neuronal degeneration in such cases. We describe the use of a snake venom-derived fibrin sealant during surgical reconnection of avulsed roots at the spinal cord surface. The present work investigates the effects of this fibrin sealant on functional recovery, neuronal survival, synaptic plasticity, and glial reaction in the spinal motoneuron microenvironment after ventral root reimplantation. METHODOLOGY/PRINCIPAL FINDINGS: Female Lewis rats (7 weeks old were subjected to VRA and root replantation. The animals were divided into two groups: 1 avulsion only and 2 replanted roots with fibrin sealant derived from snake venom. Post-surgical motor performance was evaluated using the CatWalk system twice a week for 12 weeks. The rats were sacrificed 12 weeks after surgery, and their lumbar intumescences were processed for motoneuron counting and immunohistochemistry (GFAP, Iba-1 and synaptophysin antisera. Array based qRT-PCR was used to evaluate gene regulation of several neurotrophic factors and receptors as well as inflammatory related molecules. The results indicated that the root reimplantation with fibrin sealant enhanced motor recovery, preserved the synaptic covering of the motoneurons and improved neuronal survival. The replanted group did not show significant changes in microglial response compared to VRA-only. However, the astroglial reaction was significantly reduced in this group. CONCLUSIONS/SIGNIFICANCE: In conclusion, the present data suggest that the repair of avulsed roots with snake venom fibrin glue at the exact point of detachment results in neuroprotection and preservation of the synaptic network at the microenvironment of the lesioned motoneurons. Also such procedure reduced the

  3. Motor Recovery and Synaptic Preservation after Ventral Root Avulsion and Repair with a Fibrin Sealant Derived from Snake Venom

    Science.gov (United States)

    Barbizan, Roberta; Castro, Mateus V.; Rodrigues, Antônio C.; Barraviera, Benedito; Ferreira, Rui S.; Oliveira, Alexandre L. R.

    2013-01-01

    Background Ventral root avulsion is an experimental model of proximal axonal injury at the central/peripheral nervous system interface that results in paralysis and poor clinical outcome after restorative surgery. Root reimplantation may decrease neuronal degeneration in such cases. We describe the use of a snake venom-derived fibrin sealant during surgical reconnection of avulsed roots at the spinal cord surface. The present work investigates the effects of this fibrin sealant on functional recovery, neuronal survival, synaptic plasticity, and glial reaction in the spinal motoneuron microenvironment after ventral root reimplantation. Methodology/Principal Findings Female Lewis rats (7 weeks old) were subjected to VRA and root replantation. The animals were divided into two groups: 1) avulsion only and 2) replanted roots with fibrin sealant derived from snake venom. Post-surgical motor performance was evaluated using the CatWalk system twice a week for 12 weeks. The rats were sacrificed 12 weeks after surgery, and their lumbar intumescences were processed for motoneuron counting and immunohistochemistry (GFAP, Iba-1 and synaptophysin antisera). Array based qRT-PCR was used to evaluate gene regulation of several neurotrophic factors and receptors as well as inflammatory related molecules. The results indicated that the root reimplantation with fibrin sealant enhanced motor recovery, preserved the synaptic covering of the motoneurons and improved neuronal survival. The replanted group did not show significant changes in microglial response compared to VRA-only. However, the astroglial reaction was significantly reduced in this group. Conclusions/Significance In conclusion, the present data suggest that the repair of avulsed roots with snake venom fibrin glue at the exact point of detachment results in neuroprotection and preservation of the synaptic network at the microenvironment of the lesioned motoneurons. Also such procedure reduced the astroglial reaction and

  4. Treatment of endo-periodontal lesion using leukocyte-platelet-rich fibrin. A case report.

    Science.gov (United States)

    Betancourt, Pablo; Elgueta, Ricardo; Fuentes, Ramon

    2017-12-30

    The main objective of this paper was to report the clinical effectiveness of leukocyte- platelet- rich fibrin (L-PRF) in the treatment of a combined endo-periodontal lesion of an upper first premolar. The tooth had a profound abfraction on the vestibular aspect and presented no mobility but revealed a deep pocket measuring of 11 mm on the mesial vestibular aspect and 14 mm on the mesial palatine aspect. The three dimensional image analysis showed total bone loss in the mesial aspect and an extensively bone loss of the vestibular aspect of the vestibular root. Endodontic treatment was performed and periodontal access surgery (surgical periodontal therapy) was done with the application of autologous L-PRF. Three month and 6 months after surgery, the cone beam computed tomography (CBCT) exams showed no bone regeneration in any aspect of the tooth. However, periodontal examination showed a significative improvement in the deepness of surcus. The mesial vestibular aspect had a deep pocket of 3 mm and 5 mm on the mesial palatine aspect showing a reduction in deepness of 8 mm and 9 mm, respectively. The actual treatment for teeth with bad prognosis is the extraction and replacement with implants. Even though implants are capable of restore function and aesthetic, the abuse of this approach have led to the loss of teeth that could be successfully treated with a less invasive technique. The prognosis of teeth with endoperiodontal lesion is poor but could be enhanced with regenerative therapies. Until now there are no clinical trials and just four case report about the treatment of these teeth with platelet rich fibrin.

  5. Anion embedded sol-gel films on Al for corrosion protection

    International Nuclear Information System (INIS)

    Sheffer, Mari; Groysman, Alec; Starosvetsky, David; Savchenko, Natali; Mandler, Daniel

    2004-01-01

    We report here on the successful incorporation of organic anions into a sol-gel film on Al as a means of enhancing the protection against corrosion. Following our previous study where we showed that hydrophobic sol-gel films provided pronounced corrosion inhibition, we studied the corrosion inhibition that phenylphosphonic acid (PPA) has when embedded inside a thin sol-gel coating on Al. The anion of this organic anion tends to stay inside a phenyltrimethoxysilane (PTMOS) based sol-gel film due to π-interactions. Our findings, which are derived primarily from potentiodynamic polarization measurements, electrochemical noise, scanning electron microscopy measurements and Auger electron spectroscopy (AES), clearly show that the organic phosphonate adds to the protection efficiency of the sol-gel film

  6. Protein electrophoretic migration data from custom and commercial gradient gels

    Directory of Open Access Journals (Sweden)

    Andrew J. Miller

    2016-12-01

    Full Text Available This paper presents data related to the article “A method for easily customizable gradient gel electrophoresis” (A.J. Miller, B. Roman, E.M. Norstrom, 2016 [1]. Data is presented on the rate of electrophoretic migration of proteins in both hand-poured and commercially acquired acrylamide gradient gels. For each gel, migration of 9 polypeptides of various masses was measured upon completion of gel electrophoresis. Data are presented on the migration of proteins within separate lanes of the same gel as well as migration rates from multiple gels.

  7. Thyroid Dysfunction and Fibrin Network Structure: A Mechanism for Increased Thrombotic Risk in Hyperthyroid Individuals

    NARCIS (Netherlands)

    Hooper, J. M. W.; Stuijver, D. J. F.; Orme, S. M.; van Zaane, B.; Hess, K.; Gerdes, V. E.; Phoenix, F.; Rice, P.; Smith, K. A.; Alzahrani, S. H.; Standeven, K. F.; Ajjan, R. A.

    2012-01-01

    Context: Hyperthyroidism is associated with increased thrombosis risk, and fibrin clot structure determines susceptibility to vascular thrombotic events. Objective: Our objective was to investigate clot formation and lysis in hyperthyroidism using observational and interventional studies. Design: Ex

  8. Use of fibrin glue derived from snake venom in the repair of deep corneal ulcers: experimental study in dogs (Canis familiaris, Linnaeus, 1758

    Directory of Open Access Journals (Sweden)

    R. L. Sampaio

    2007-01-01

    Full Text Available Fibrin glue has been researched as an alternative method for tissue synthesis and is known for its capability to promote hemostasis at the application site, good approximation of wound edges and fast healing. The current study consisted in the application of fibrin glue derived from snake venom as treatment for experimental corneal ulcers. Twenty-one dogs had their corneas experimentally prepared through lamellar keratectomy (of standardized diameter and depth. Animals were divided into seven groups of three animals each. Six experimental groups were periodically evaluated and collection was carried out on the 1st, 3rd, 7th, 15th, 30th and 60th post-operative days, whereas one control group was evaluated throughout the experiment. Analyses consisted in the clinical evolution and in the histopathological study of all operated on eyes. Results indicated that fibrin glue was efficient in repairing keratectomy wounds in dogs and contributed to an earlier healing phenomenon, avoiding edema formation and keeping corneal clearness. The use of fibrin glue derived from snake venom showed to be easy to apply, feasible with animal models and of low cost, avoiding the lesion progress and allowing fast and appropriate corneal healing.

  9. Microbicidal properties of Leukocyte- and Platelet-Rich Plasma/Fibrin (L-PRP/L-PRF): new perspectives.

    Science.gov (United States)

    Cieslik-Bielecka, A; Dohan Ehrenfest, D M; Lubkowska, A; Bielecki, T

    2012-01-01

    Platelets, as main actors of the first stage of the healing process, play an important role in tissue repair. Their granules contain many active substances, particularly over 30 growth factors with significant effects on the resident cells at the site of injury, such as mesenchymal stem cells, chondrocytes, fibroblasts, osteoblasts. This potential may be increased by the concentration of the platelets, using platelet-rich plasma/fibrin products. In the four families of platelet concentrates, 2 families contain also significant concentrations of leukocytes: L-PRP (Leukocyte- and Platelet-Rich Plasma) and L-PRF (Leukocyte- and Platelet-Rich Fibrin). Inductive properties of platelet concentrates were widely described. However, they present also antimicrobial effects. The antibacterial effects of L-PRP were highlighted in only a few in vitro studies. Strong activity comparable to gentamicin and oxacillin for L-PRP against methicillin susceptible Staphylococcus aureus (MSSA) was already demonstrated. L-PRP also inhibited the growth of methicillin resistant Staphylococcus aureus (MRSA) and Escherichia coli. Some authors also reported clinical observations about the reduction of infections and the induction of healing processes after the use of platelet concentrates in cardiac, orthopaedic, oral and maxillofacial surgery. However, very little is yet known about the antibacterial effects of these concentrates. In this manuscript, the current data about the antimicrobial agents and cells present in the platelet-rich plasma/fibrin are highlighted and discussed, in order to introduce this new key chapter of the platelet concentrate technology history.

  10. In vivo evaluation of titanium-prepared platelet-rich fibrin (T-PRF): a new platelet concentrate.

    Science.gov (United States)

    Tunalı, Mustafa; Özdemir, Hakan; Küçükodacı, Zafer; Akman, Serhan; Fıratlı, Erhan

    2013-07-01

    We have developed a new, titanium-prepared, platelet-rich fibrin (T-PRF) together with the protocol for forming it, which is based on the hypothesis that titanium tubes may be more effective at activating platelets than the glass tubes used by Chouckroun in his platelet-rich fibrin (PRF) method. The aim of this study was to find a suitable animal model in which to evaluate the method and to investigate the efficacy of T-PRF for wound healing. Blood samples from 6 rabbits were used to confirm the protocol for formation of T-PRF. We evaluated T-PRF or T-PRF-like clots morphologically using scanning electron microscopy (EM). Blood samples from 5 rabbits were used to develop an experiment in which to evaluate the effects of T-PRF on wound healing. The mucoperiosteal flaps were filled with autologous T-PRF membranes from the vestibule in the anterior mandibular regions. Samples collected from the surgical sites were stained with haematoxylin and eosin. We found a mature fibrin network in T-PRF clots that had been centrifuged for 15 min at 3500 rpm and, 15 days after placement of the membrane, we found newly-forming connective tissue and islets of bony tissue in the T-PRF membrane. These results show that T-PRF could induce the formation of new bone with new connective tissue in a rabbit model of wound healing within 30 days of treatment. Published by Elsevier Ltd.

  11. Morphogen and proinflammatory cytokine release kinetics from PRGF-Endoret fibrin scaffolds: evaluation of the effect of leukocyte inclusion.

    Science.gov (United States)

    Anitua, E; Zalduendo, M M; Prado, R; Alkhraisat, M H; Orive, G

    2015-03-01

    The potential influence of leukocyte incorporation in the kinetic release of growth factors from platelet-rich plasma (PRP) may explain the conflicting efficiency of leukocyte platelet-rich plasma (L-PRP) scaffolds in tissue regeneration. To assess this hypothesis, leukocyte-free (PRGF-Endoret) and L-PRP fibrin scaffolds were prepared, and both morphogen and proinflammatory cytokine release kinetics were analyzed. Clots were incubated with culture medium to monitor protein release over 8 days. Furthermore, the different fibrin scaffolds were morphologically characterized. Results show that leukocyte-free fibrin matrices were homogenous while leukocyte-containing ones were heterogeneous, loose and cellular. Leukocyte incorporation produced a significant increase in the contents of proinflammatory cytokines interleukin (IL)-1β and IL-16 but not in the platelet-derived growth factors release (PRGF-Endoret, the inclusion of leukocytes induced a major increase in these cytokines, which was characterized by the presence of a latent period. The PRGF-Endoret matrices were stable during the 8 days of incubation. The inclusion of leukocytes alters the growth factors release profile and also increased the dose of proinflammatory cytokines. © 2014 Wiley Periodicals, Inc.

  12. Sol-Gel Glasses

    Science.gov (United States)

    Mukherjee, S. P.

    1985-01-01

    Multicomponent homogeneous, ultrapure noncrystalline gels/gel derived glasses are promising batch materials for the containerless glass melting experiments in microgravity. Hence, ultrapure, homogeneous gel precursors could be used to: (1) investigate the effect of the container induced nucleation on the glass forming ability of marginally glass forming compositions; and (2) investigate the influence of gravity on the phase separation and coarsening behavior of gel derived glasses in the liquid-liquid immiscibility zone of the nonsilicate systems having a high density phase. The structure and crystallization behavior of gels in the SiO2-GeO2 as a function of gel chemistry and thermal treatment were investigated. As are the chemical principles involved in the distribution of a second network former in silica gel matrix being investigated. The procedures for synthesizing noncrystalline gels/gel-monoliths in the SiO2-GeO2, GeO2-PbO systems were developed. Preliminary investigations on the levitation and thermal treatment of germania silicate gel-monoliths in the Pressure Facility Acoustic Levitator were done.

  13. Laminin-111-derived peptide conjugated fibrin hydrogel restores salivary gland function.

    Directory of Open Access Journals (Sweden)

    Kihoon Nam

    Full Text Available Hyposalivation reduces the patient quality of life, as saliva is important for maintaining oral health. Current treatments for hyposalivation are limited to medications such as the muscarinic receptor agonists, pilocarpine and cevimeline. However, these therapies only provide temporary relief. Therefore, alternative therapies are essential to restore salivary gland function. An option is to use bioengineered scaffolds to promote functional salivary gland regeneration. Previous studies demonstrated that the laminin-111 protein is critical for intact salivary gland cell cluster formation and organization. However, laminin-111 protein as a whole is not suitable for clinical applications as some protein domains may contribute to unwanted side effects such as degradation, tumorigenesis and immune responses. Conversely, the use of synthetic laminin-111 peptides makes it possible to minimize the immune reactivity or pathogen transfer. In addition, it is relatively simple and inexpensive as compared to animal-derived proteins. Therefore, the goal of this study was to demonstrate whether a 20 day treatment with laminin-111-derived peptide conjugated fibrin hydrogel promotes tissue regeneration in submandibular glands of a wound healing mouse model. In this study, laminin-111-derived peptide conjugated fibrin hydrogel significantly accelerated formation of salivary gland tissue. The regenerated gland tissues displayed not only structural but also functional restoration.

  14. Aging and nonlinear rheology of thermoreversible colloidal gels

    Science.gov (United States)

    Wagner, Norman; Gordon, Melissa; Kloxin, Christopher

    Colloidal dispersions are found in a wide variety of consumer products such as paint, food and pharmaceuticals. We investigate gel formation and aging in a thermoreverible gel consisting of octadecyl-coated silica nanoparticles suspended in n-tetradecane. In this system, the octadecyl brush can undergo a phase change allowing the attractions between particles to be tuned by temperature (1,2). By probing the system with steady shear and large amplitude oscillatory shear, we have studied the effect of thermal history and shear history on gel formation and gel mechanical properties during aging. Gels were formed by approaching a common temperature from above and below to determine a reference state from which creep tests were conducted. Creep ringing was observed as expected for the viscoelastic gel. The rheological aging is interpreted in terms of the gel microstructure formed with differing thermal and shear histories to determine how processing affects structure. Recently proposed scaling laws for the rheology and structure under flow are explored within the context of gel aging (3). Through rheological and microstructural measurements, we will further the understanding of gel formation and aging in this model system which may be applied to processing conditions in an industrial setting.

  15. Biocatalysis with Sol-Gel Encapsulated Acid Phosphatase

    Science.gov (United States)

    Kulkarni, Suhasini; Tran, Vu; Ho, Maggie K.-M.; Phan, Chieu; Chin, Elizabeth; Wemmer, Zeke; Sommerhalter, Monika

    2010-01-01

    This experiment was performed in an upper-level undergraduate biochemistry laboratory course. Students learned how to immobilize an enzyme in a sol-gel matrix and how to perform and evaluate enzyme-activity measurements. The enzyme acid phosphatase (APase) from wheat germ was encapsulated in sol-gel beads that were prepared from the precursor…

  16. Acute fibrinous and organising pneumonia: a rare histopathological variant of chemotherapy-induced lung injury.

    Science.gov (United States)

    Gupta, Arjun; Sen, Shiraj; Naina, Harris

    2016-04-06

    Bleomycin-induced lung injury is the most common chemotherapy-associated lung disease, and is linked with several histopathological patterns. Acute fibrinous and organising pneumonia (AFOP) is a relatively new and rare histological pattern of diffuse lung injury. We report the first known case of bleomycin-induced AFOP. A 36-year-old man with metastatic testicular cancer received three cycles of bleomycin, etoposide and cisplatin, before being transitioned to paclitaxel, ifosfamide and cisplatin. He subsequently presented with exertional dyspnoea, cough and pleuritic chest pain. CT of the chest demonstrated bilateral ground glass opacities with peribronchovascular distribution and pulmonary function tests demonstrated a restrictive pattern of lung disease with impaired diffusion. Transbronchial biopsy revealed intra-alveolar fibrin deposits with organising pneumonia, consisting of intraluminal loose connective tissue consistent with AFOP. The patient received high-dose corticosteroids with symptomatic and radiographic improvement. AFOP should be recognised as a histopathological variant of bleomycin-induced lung injury. 2016 BMJ Publishing Group Ltd.

  17. Platelet rich fibrin (Prf) and β-tricalcium phosphate with coronally advanced flap for the management of grade-II furcation defect.

    Science.gov (United States)

    Sambhav, Jain; Rohit, Rai; Ranjana, Mohan; Shalabh, Mehrotra

    2014-07-01

    Multirooted teeth offer unique and challenging problems due to the furcation area, creates situations in which routine periodontal procedures are somewhat limited and special procedures are generally required. The present case was showing the management of grade II furcation defect by platelet rich fibrin (PRF) and β-Tricalcium phosphate with coronally advanced flap. Platelet rich fibrin and β-Tricalcium phosphate with coronally advanced flap have been shown to be a promising and successful approach for the treatment of furcation defect. Its gaining clinical attachment significantly manages both the gingival recession and furcation involvement simultaneously.

  18. Autologous fibrin glue as an encapsulating scaffold for delivery of retinal progenitor cells

    Directory of Open Access Journals (Sweden)

    Tamer Anwar Esmail Ahmed

    2015-02-01

    Full Text Available The retina is a highly sophisticated piece of the neural machinery that begins the translation of incoming light signals into meaningful visual information. Several degenerative diseases of the retina are characterized by photoreceptor loss and eventually lead to irreversible blindness. Regenerative medicine, using tissue engineering-based constructs to deliver progenitor cells or photoreceptors along with supporting carrier matrix is a promising approach for restoration of structure and function. Fresh fibrin glue (FG produced by the CryoSeal®FS system in combination with mouse retinal progenitor cells (RPCs were evaluated in this study. In vitro expanded RPCs isolated from postnatal mouse retina were encapsulated into FG and cultured in the presence of the protease inhibitor, tranexamic acid. Encapsulation of RPCs into FG did not show adverse effects on cell proliferation or cell survival. RPCs exhibited fibroblast-like morphology concomitantly with attachment to the encapsulating FG surface. They expressed α7 and β3 integrin subunits that could mediate attachment to fibrin matrix via an RGD independent mechanism. The three dimensional environment and the attachment surface provided by FG was associated with a rapid downregulation of the progenitor marker SOX2 and enhanced the expression of the differentiation markers CRX and recoverin. However, the in vitro culture conditions did not promote full differentiation into mature photoreceptors. Nevertheless, we have shown that autologous fibrin, when fabricated into a scaffold for RPCs for delivery to the retina, provides the cells with external cues that could potentially improve the differentiation events. Hence, transient encapsulation of RPCs into FG could be a valid and potential treatment strategy to promote retinal regeneration following degenerative diseases. However, further optimization is necessary to maximize the outcomes in terms of mature photoreceptors.

  19. Influence of oxidative stress onto fibrin net formation, architecture and lysis

    Czech Academy of Sciences Publication Activity Database

    Štikarová, J.; Kotlín, R.; Suttnar, J.; Riedel, T.; Šácha, Pavel; Májek, P.; Chrastinová, L.; Hlaváčková, A.; Dyr, J. E.

    2015-01-01

    Roč. 13, Suppl 2 (2015), s. 837-838 ISSN 1538-7933. [ISTH 2015. Congress of the International Society on Thrombosis and Haemostasis /25./ and Annual SSC Meeting /61./. 20.06.2015-25.06.2015, Toronto] Grant - others:GA ČR(CZ) GBP205/12/G118; OPPK(CZ) CZ.2.16/3.1.00/24001 Program:GB Institutional support: RVO:61388963 Keywords : fibrinogen modification * fibrin net * oxidative stress Subject RIV: CE - Biochemistry

  20. Acute Fibrinous and Organizing Pneumonia Associated With Allogenic Hematopoietic Stem Cell Transplant Successfully Treated With Corticosteroids

    Directory of Open Access Journals (Sweden)

    Lam-Phuong Nguyen DO

    2016-04-01

    Full Text Available Acute fibrinous and organizing pneumonia (AFOP is an extremely rare, relatively new, and distinct histological pattern of acute lung injury characterized predominately by the presence of intra-alveolar fibrin and associated organizing pneumonia. AFOP may be idiopathic or associated with a wide spectrum of clinical conditions. It has a variable clinical presentation from mild respiratory symptoms to that similar to the acute respiratory distress syndrome. Currently there is no consensus on treatment, and corticosteroids previously were of unclear benefit. To date, there are less than 40 cases of AFOP reported in the literature and only one has been linked to hematopoietic stem cell transplantation. Here we report the first case series of 2 patients who developed AFOP following allogenic stem cell transplant that were successfully treated with high-dose corticosteroids.

  1. Preparation of silica by sol-gel method using formamide

    Directory of Open Access Journals (Sweden)

    R.F.S. Lenza

    2001-07-01

    Full Text Available In this work we obtained microporous and mesoporous silica gels by sol-gel processing. Tetraethylortosilicate (TEOS was used as precursor. Nitric acid and hydrofluoric acid were used as catalysts. In order to study the affect of formamide as drying additive, we used a molar ratio alkoxide/formamide of 1/1. The performance of formamide in obtaining crack-free gels was evaluated through monolithicity measurements. The structural evolution occurring in the interconnected network of the gels during thermal treatment was monitored by Fourier transform infrared spectroscopy (FTIR, shrinkage and density measurements and nitrogen gas sorption. We noted that in the presence of formamide, the Si-O-Si bonds are stronger and belong to a more cross-linked structure. The samples obtained in the presence of formamide have larger pore volume and its pore structure is in the range of mesoporosity. The samples obtained without additive are microporous. Formamide allowed the preparation of crack-free silica gels stabilized at high temperatures.

  2. A three-dimensional cell-loading system using autologous plasma loaded into a porous β-tricalcium-phosphate block promotes bone formation at extraskeletal sites in rats

    International Nuclear Information System (INIS)

    Tajima, Nobutaka; Sotome, Shinichi; Marukawa, Eriko; Omura, Ken; Shinomiya, Kenichi

    2007-01-01

    The effects of platelet-rich plasma (PRP) and platelet-poor plasma (PPP) on bone marrow stromal cells (MSCs) with respect to proliferation, osteogenic differentiation, and bone formation capability were investigated. MSCs derived from rats were cultured in medium containing mixtures of PRP and PPP. Fibrinogen was eliminated prior to the experiment. The DNA content and alkaline phosphatase (ALP) activity were measured. PRP stimulated cell proliferation and inhibited osteoblastic differentiation. To examine the effects of fibrin in plasma, MSCs were cultured in PRP or PPP fibrin gels formed both on a cell culture insert installed in a culture well and on the bottom surface of the same culture well. The ALP activities of the MSCs in both of the gels were higher than those on the surface of the culture wells. The MSCs cultured on the PPP gel showed the highest ALP activity. The effects of PRP and PPP used as scaffolds for bone formation were also investigated. MSCs were suspended in PRP or PPP, introduced into porous β-tricalcium phosphate blocks, and then implanted into subcutaneous sites. Subsequently, bone formation was quantified. Further in vivo studies found that implants prepared using PPP had a greater osteoinductive capability than implants prepared with PRP

  3. A three-dimensional cell-loading system using autologous plasma loaded into a porous {beta}-tricalcium-phosphate block promotes bone formation at extraskeletal sites in rats

    Energy Technology Data Exchange (ETDEWEB)

    Tajima, Nobutaka [Oral and Maxillofacial Surgery, Graduate school, Tokyo Medical and Dental University (Japan); Orthopaedic and Spinal Surgery, Graduate school, Tokyo Medical and Dental University (Japan); Sotome, Shinichi [Orthopaedic and Spinal Surgery, Graduate school, Tokyo Medical and Dental University (Japan); Marukawa, Eriko [Oral and Maxillofacial Surgery, Graduate school, Tokyo Medical and Dental University (Japan); Orthopaedic and Spinal Surgery, Graduate school, Tokyo Medical and Dental University (Japan); Omura, Ken [Oral and Maxillofacial Surgery, Graduate school, Tokyo Medical and Dental University (Japan); Center of Excellence Program for Frontier Research on Molecular Destruction and Reconstruction of Tooth and Bone, Tokyo Medical and Dental University (Japan); Shinomiya, Kenichi [Orthopaedic and Spinal Surgery, Graduate school, Tokyo Medical and Dental University (Japan) and Center of Excellence Program for Frontier Research on Molecular Destruction and Reconstruction of Tooth and Bone, Tokyo Medical and Dental University (Japan) and Advanced Bone and Joint Science (Japan)]. E-mail: shinomiya.orth@tmd.ac.jp

    2007-05-16

    The effects of platelet-rich plasma (PRP) and platelet-poor plasma (PPP) on bone marrow stromal cells (MSCs) with respect to proliferation, osteogenic differentiation, and bone formation capability were investigated. MSCs derived from rats were cultured in medium containing mixtures of PRP and PPP. Fibrinogen was eliminated prior to the experiment. The DNA content and alkaline phosphatase (ALP) activity were measured. PRP stimulated cell proliferation and inhibited osteoblastic differentiation. To examine the effects of fibrin in plasma, MSCs were cultured in PRP or PPP fibrin gels formed both on a cell culture insert installed in a culture well and on the bottom surface of the same culture well. The ALP activities of the MSCs in both of the gels were higher than those on the surface of the culture wells. The MSCs cultured on the PPP gel showed the highest ALP activity. The effects of PRP and PPP used as scaffolds for bone formation were also investigated. MSCs were suspended in PRP or PPP, introduced into porous {beta}-tricalcium phosphate blocks, and then implanted into subcutaneous sites. Subsequently, bone formation was quantified. Further in vivo studies found that implants prepared using PPP had a greater osteoinductive capability than implants prepared with PRP.

  4. Pathology Report for Intraperitoneal Sodium Dichromate Exposure in Rats

    Science.gov (United States)

    2015-08-12

    injury resulting from exposure to specific metal intoxication . The investigators aim was to validate hypothesized adverse outcome pathways in rats...vessels causing them to become leaky. Injured or inflamed vessels lead to extravasated fibrinogen which rapidly clots into a cross-linked fibrin gel...Sprague-Dawley rats appear to include direct injury to the exposed, capsular surface of the liver, leading to fibrinogen leakage, fibrin formation

  5. Platelets as Contractile Nanomachines for Targeting Drug Delivery in Hemostasis and Thrombosis

    Science.gov (United States)

    2015-12-01

    capsules were suspended in platelet - rich plasma, which was subsequently exposed to 1 U/mL of thrombin, the capsules successfully targeted target...thrombotic sites via integration into the forming fibrin networks and binding to activated platelets . The delivery vehicles successfully adhere to platelet ...rupture has successfully been achieved in static fibrin gels comprised of a high concentration of platelets (Figure 3). Only capsules incorporated into

  6. Optimal diagnostic measures and thresholds for hypogonadism in men with HIV/AIDS: comparison between 2 transdermal testosterone replacement therapy gels.

    Science.gov (United States)

    Blick, Gary

    2013-03-01

    To determine the incidence of hypogonadism in men with human immunodeficiency virus (HIV)/acquired immunodeficiency virus (AIDS), the most useful serum testosterone measurement and threshold for diagnosing hypogonadism, and the comparative efficacy of 2 testosterone replacement therapy (TRT) 1% gels (AndroGel® [Abbott Laboratories] and Testim® [Auxilium Pharmaceuticals, Inc.]). This was a 2-stage observational study. In stage 1, patient records from 2 medical practices specializing in HIV/AIDS were reviewed. Eligible patients were aged ≥ 18 years; had HIV-seropositive status confirmed by enzyme-linked immunosorbent assay and western blot test or HIV-1 viremia confirmed by HIV-1 RNA polymerase chain reaction; and had prior baseline testosterone assessments for hypogonadism (ie, presence of signs/symptoms of hypogonadism as well as total testosterone [TT] and free testosterone [FT] level measurements). Stage 2 included the evaluation of patients from stage 1 who were treated with 5 to 10 g/day of TRT. The stage 2 inclusion criteria were a diagnosis of low testosterone (defined as TT level < 300 ng/dL and/or FT level < 50 pg/mL, as per The Endocrine Society guidelines and presence/absence of hypogonadal signs and symptoms); ≥ 12 months of evaluable sign and symptom assessments and TT/FT level measurements while on TRT with either Testim® or AndroGel®; and ≥ 4 weeks on initial TRT if the initial TRT was switched or discontinued. Four hundred one of 422 patients met the stage 1 inclusion criteria and 167 of 401 patients (AndroGel®, n = 92; Testim®, n = 75) met the stage 2 inclusion criteria. Total testosterone level < 300 ng/dL alone identified 24% (94 of 390) of patients as hypogonadal, but failed to diagnose an additional 111 patients (67.7%) with FT levels < 100 pg/mL and hypogonadal symptoms. Through month 12, AndroGel® increased mean TT levels by +42.8% and FT levels by +66.9%, compared with +178.7% (P = 0.017) and +191% (P = 0.039), respectively, for

  7. Impaired platelet adhesion to lysed fibrin, whereas neutrophil adhesion remains intact under conditions of flow

    NARCIS (Netherlands)

    Remijn, Jasper A.; da Costa Martins, Paula; Ijsseldijk, Martin J. W.; Sixma, Jan J.; de Groot, Philip G.; Zwaginga, Jaap J.

    2006-01-01

    Vessel wall injury induces the formation of a haemostatic plug. Restoration of vascular integrity should involve cessation of further platelet and fibrin deposition and subsequent removal of these thrombi by both the fibrinolytic system and proteases delivered by infiltrating inflammatory cells. We

  8. Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue.

    NARCIS (Netherlands)

    Hallers, E.J.O. ten; Jansen, J.A.; Marres, H.A.M.; Rakhorst, G.; Verkerke, G.J.

    2007-01-01

    Polypropylene (PP) and titanium (Ti) meshes are well-known surgical implants that provoke a relative low foreign body reaction. Firm stabilization of the implant is important to prevent migration and subsequent failure of the operation. Fibrin tissue glues are commercially available adhesives and

  9. Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue

    NARCIS (Netherlands)

    ten Hallers, E.J. Olivier; Jansen, John A.; Marres, Henri A.M.; Rakhorst, Gerhard; Verkerke, Gijsbertus Jacob

    2007-01-01

    Polypropylene (PP) and titanium (Ti) meshes are well-known surgical implants that provoke a relative low foreign body reaction. Firm stabilization of the implant is important to prevent migration and subsequent failure of the operation. Fibrin tissue glues are commercially available adhesives and

  10. Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue

    NARCIS (Netherlands)

    ten Hallers, E. J. Olivier; Jansen, John A.; Marres, Henri A. M.; Rakhorst, Gerhard; Verkerke, Gijsbertus J.

    Polypropylene (PP) and titanium (Ti) meshes are well-known surgical implants that provoke a relative low foreign body reaction. Firm stabilization of the implant is important to prevent migration and subsequent failure of the operation. Fibrin tissue glues are commercially available adhesives and

  11. Role of gel dosimeters in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Khajeali, Azim; Farajollahi, Ali Reza; Khodadadi, Roghayeh; Kasesaz, Yaser; Khalili, Assef

    2015-01-01

    Gel dosimeters have acquired a unique status in radiotherapy, especially with the advent of the new techniques in which there is a need for three-dimensional dose measurement with high spatial resolution. One of the techniques in which the use of gel dosimeters has drawn the attention of the researchers is the boron neutron capture therapy. Exploring the history of gel dosimeters, this paper sets out to study their role in the boron neutron capture therapy dosimetric process. - Highlights: • Gel dosimeters have been investigated. • Conventional dosimetric proses of BNCT has been investigated. • Role of gel dosimeters in BNCT has been investigated

  12. Further developments and applications of layer gel dosimetry

    International Nuclear Information System (INIS)

    Gambarini, G; Carrara, M; Colli, V; Gay, S; Tomatis, S

    2004-01-01

    The method used to perform dosimetry with Fricke-xylenol orange-infused gels in form of layers remains the most reliable method for in-phantom dose profiling and imaging in high fluxes of thermal and epithermal neutrons. Gel-dosimeters in form of layers really give the possibility not only of obtaining spatial dose distributions but also of achieving measurements of each dose contribution in neutron fields. These advantages arise from the layer-geometry thanks to which neutron transport is not sensibly altered, even if the elemental gel composition is changed adding particular isotopes (for example 10 B), as necessary to perform the separation of dose contributions. The gel matrix composition and the experimental procedures, adopted for both dosimeter preparation and analysis, have been already described in previous works. In the present work, the improvements of the method employed for gel analysis, dose imaging and gel applications are illustrated

  13. Encapsulation of biological species in sol-gel matrices

    International Nuclear Information System (INIS)

    Finnie, K.S.; Bartlett, J.R.; Woolfrey, J.L.

    2000-01-01

    Two examples are given of the gelation of silica sols containing bio catalysts, resulting in their encapsulation in porous matrices. Urease was encapsulated in gels made from a mixture of TMOS and alkyltrimethoxysilane. Enzyme activities, monitored by measuring the rate of production of ammoniacal nitrogen as urea was decomposed, ranged up to 60% of that of the unencapsulated species. Anaerobic sulphate-reducing bacteria were encapsulated in a gel produced from colloidal silica, thus avoiding contact with alcohol. The detection of H 2 S produced in the doped gel indicated that the bacteria were able to continue normal metabolic function within the gel matrix. A gel initially doped with ∼ 5 x 10 5 cells cm -3 , exhibited an optimum sulphate reduction rate of 11 ug h -1 cm -3 ; this reduction rate was quickly re-established after storage of the gel for 14 weeks. Copyright (2000) The Australian Ceramic Society

  14. GelTouch

    DEFF Research Database (Denmark)

    Miruchna, Viktor; Walter, Robert; Lindlbauer, David

    2015-01-01

    We present GelTouch, a gel-based layer that can selectively transition between soft and stiff to provide tactile multi-touch feedback. It is flexible, transparent when not activated, and contains no mechanical, electromagnetic, or hydraulic components, resulting in a compact form factor (a 2mm thin...... touchscreen layer for our prototype). The activated areas can be morphed freely and continuously, without being limited to fixed, predefined shapes. GelTouch consists of a poly(N-isopropylacrylamide) gel layer which alters its viscoelasticity when activated by applying heat (>32 C). We present three different...

  15. Soluble fibrin inhibits monocyte adherence and cytotoxicity against tumor cells: implications for cancer metastasis

    Directory of Open Access Journals (Sweden)

    Patel Shonak

    2006-08-01

    Full Text Available Abstract Background Soluble fibrin (sFn is a marker for disseminated intravascular coagulation and may have prognostic significance, especially in metastasis. However, a role for sFn in the etiology of metastatic cancer growth has not been extensively studied. We have reported that sFn cross-linked platelet binding to tumor cells via the major platelet fibrin receptor αIIbβ3, and tumor cell CD54 (ICAM-1, which is the receptor for two of the leukocyte β2 integrins (αLβ2 and aMβ2. We hypothesized that sFn may also affect leukocyte adherence, recognition, and killing of tumor cells. Furthermore, in a rat experimental metastasis model sFn pre-treatment of tumor cells enhanced metastasis by over 60% compared to untreated cells. Other studies have shown that fibrin(ogen binds to the monocyte integrin αMβ2. This study therefore sought to investigate the effect of sFn on β2 integrin mediated monocyte adherence and killing of tumor cells. Methods The role of sFn in monocyte adherence and cytotoxicity against tumor cells was initially studied using static microplate adherence and cytotoxicity assays, and under physiologically relevant flow conditions in a microscope perfusion incubator system. Blocking studies were performed using monoclonal antibodies specific for β2 integrins and CD54, and specific peptides which inhibit sFn binding to these receptors. Results Enhancement of monocyte/tumor cell adherence was observed when only one cell type was bound to sFn, but profound inhibition was observed when sFn was bound to both monocytes and tumor cells. This effect was also reflected in the pattern of monocyte cytotoxicity. Studies using monoclonal blocking antibodies and specific blocking peptides (which did not affect normal coagulation showed that the predominant mechanism of fibrin inhibition is via its binding to αMβ2 on monocytes, and to CD54 on both leukocytes and tumor cells. Conclusion sFn inhibits monocyte adherence and cytotoxicity of

  16. Structural and optical studies of nano-structure silica gel doped with different rare earth elements, prepared by two different sol -gel techniques

    International Nuclear Information System (INIS)

    Battisha, I.K.; El Beyally, A.; Seliman, S.I.; El Nahrawi, A.S.

    2005-01-01

    Structural and optical characteristics of pure silica gel (silica-xerogel, SiO 2 ) and doped with different concentrations ranging from 1 up to 6% of some rare earth (REEs) ions such as, praseodymium Pr +3 ,and Europium Eu +3 , Erbium Er +3 and Holmium Ho +3 , ions, in the form of thin film and monolith materials were prepared by sol - gel technique, Using tetra-ethoxysilane as precursor materials, which are of particular interest for sol-gel integrated optics applications. Some structural and optical features of sol-gel derived monolith and thin films are analyzed and compared, namely the structure of nano-particle monolith and thin film silica-gel samples, based on X-ray diffraction (XRD). The types of structural information obtainable are compared in detail. It is show that the XRD spectra of a-cristobalite are obtained for the two type materials and even by doping with the four REEs ions. Optical measurements of monolith and thin films were also studied and compared, the normal transmission and specular reflection were measured. The refractive index were calculated and discussed

  17. Plasma fibrin clot properties in the G20210A prothrombin mutation carriers following venous thromboembolism: the effect of rivaroxaban.

    Science.gov (United States)

    Janion-Sadowska, Agnieszka; Natorska, Joanna; Siudut, Jakub; Ząbczyk, Michal; Stanisz, Andrzej; Undas, Anetta

    2017-08-30

    We sought to investigate whether the G20210A prothrombin mutation modifies plasma fibrin clot properties in patients after venous thromboembolism (VTE) and how rivaroxaban treatment affects these alterations. We studied 34 prothrombin mutation heterozygous carriers and sex- and age-matched 34 non-carriers, all at least three months since the first VTE episode, before and during treatment with rivaroxaban. Clot permeability (K s ) and clot lysis time (CLT) with or without elimination of thrombin activatable fibrinolysis inhibitor (TAFI) were assessed at baseline, 2-6 hours (h) after and 20-25 h after intake of rivaroxaban (20 mg/day). At baseline, the prothrombin mutation group formed denser clots (K s -12 %, p=0.0006) and had impaired fibrinolysis (CLT +14 %, p=0.004, and CLT-TAFI +13 %, p=0.03) compared with the no mutation group and were similar to those observed in 15 healthy unrelated prothrombin mutation carriers. The G20210A prothrombin mutation was the independent predictor for K s and CLT before rivaroxaban intake. At 2-6 h after rivaroxaban intake, clot properties improved in both G20210A carriers and non-carriers (K s +38 %, and +37 %, CLT -25 % and -25 %, CLT-TAFI -20 % and -24 %, respectively, all pCLT +17 %, CLT-TAFI +13 %, all p<0.001). Rivaroxaban concentration correlated with fibrin clot properties. After 20-25 h since rivaroxaban intake most clot properties returned to baseline. Rivaroxaban-related differences in clot structure were confirmed by scanning electron microscopy images. In conclusion, rivaroxaban treatment, though improves fibrin clot properties, cannot abolish more prothrombotic fibrin clot phenotype observed in prothrombin mutation carriers following VTE.

  18. Differentiation within autologous fibrin scaffolds of porcine dermal cells with the mesenchymal stem cell phenotype

    International Nuclear Information System (INIS)

    Puente, Pilar de la; Ludeña, Dolores; López, Marta; Ramos, Jennifer; Iglesias, Javier

    2013-01-01

    Porcine mesenchymal stem cells (pMSCs) are an attractive source of cells for tissue engineering because their properties are similar to those of human stem cells. pMSCs can be found in different tissues but their dermal origin has not been studied in depth. Additionally, MSCs differentiation in monolayer cultures requires subcultured cells, and these cells are at risk of dedifferentiation when implanting them into living tissue. Following this, we attempted to characterize the MSCs phenotype of porcine dermal cells and to evaluate their cellular proliferation and differentiation in autologous fibrin scaffolds (AFSs). Dermal biopsies and blood samples were obtained from 12 pigs. Dermal cells were characterized by flow cytometry. Frozen autologous plasma was used to prepare AFSs. pMSC differentiation was studied in standard structures (monolayers and pellets) and in AFSs. The pMSCs expressed the CD90 and CD29 markers of the mesenchymal lineage. AFSs afforded adipogenic, osteogenic and chondrogenic differentiation. The porcine dermis can be proposed to be a good source of MSCs with adequate proliferative capacity and a suitable expression of markers. The pMSCs also showed optimal proliferation and differentiation in AFSs, such that these might serve as a promising autologous and implantable material for use in tissue engineering. -- Highlights: ► Low fibrinogen concentration provides a suitable matrix for cell migration and differentiation. ► Autologous fibrin scaffolds is a promising technique in tissue engineering. ► Dermal cells are an easily accessible mesenchymal stem cell source. ► Fibrin scaffolds afforded adipogenic, osteogenic and chondrogenic differentiation.

  19. The gel electrophoresis markup language (GelML) from the Proteomics Standards Initiative.

    Science.gov (United States)

    Gibson, Frank; Hoogland, Christine; Martinez-Bartolomé, Salvador; Medina-Aunon, J Alberto; Albar, Juan Pablo; Babnigg, Gyorgy; Wipat, Anil; Hermjakob, Henning; Almeida, Jonas S; Stanislaus, Romesh; Paton, Norman W; Jones, Andrew R

    2010-09-01

    The Human Proteome Organisation's Proteomics Standards Initiative has developed the GelML (gel electrophoresis markup language) data exchange format for representing gel electrophoresis experiments performed in proteomics investigations. The format closely follows the reporting guidelines for gel electrophoresis, which are part of the Minimum Information About a Proteomics Experiment (MIAPE) set of modules. GelML supports the capture of metadata (such as experimental protocols) and data (such as gel images) resulting from gel electrophoresis so that laboratories can be compliant with the MIAPE Gel Electrophoresis guidelines, while allowing such data sets to be exchanged or downloaded from public repositories. The format is sufficiently flexible to capture data from a broad range of experimental processes, and complements other PSI formats for MS data and the results of protein and peptide identifications to capture entire gel-based proteome workflows. GelML has resulted from the open standardisation process of PSI consisting of both public consultation and anonymous review of the specifications.

  20. The control of epidermal stem cells (holoclones) in the treatment of massive full-thickness burns with autologous keratinocytes cultured on fibrin.

    Science.gov (United States)

    Pellegrini, G; Ranno, R; Stracuzzi, G; Bondanza, S; Guerra, L; Zambruno, G; Micali, G; De Luca, M

    1999-09-27

    Cell therapy is an emerging therapeutic strategy aimed at replacing or repairing severely damaged tissues with cultured cells. Epidermal regeneration obtained with autologous cultured keratinocytes (cultured autografts) can be life-saving for patients suffering from massive full-thickness burns. However, the widespread use of cultured autografts has been hampered by poor clinical results that have been consistently reported by different burn units, even when cells were applied on properly prepared wound beds. This might arise from the depletion of epidermal stem cells (holoclones) in culture. Depletion of holoclones can occur because of (i) incorrect culture conditions, (ii) environmental damage of the exposed basal layer of cultured grafts, or (iii) use of new substrates or culture technologies not pretested for holoclone preservation. The aim of this study was to show that, if new keratinocyte culture technologies and/or "delivery systems" are proposed, a careful evaluation of epidermal stem cell preservation is essential for the clinical performance of this life-saving technology. Fibrin was chosen as a potential substrate for keratinocyte cultivation. Stem cells were monitored by clonal analysis using the culture system originally described by Rheinwald and Green as a reference. Massive full-thickness burns were treated with the composite allodermis/cultured autograft technique. We show that: (i) the relative percentage of holoclones, meroclones, and paraclones is maintained when keratinocytes are cultivated on fibrin, proving that fibrin does not induce clonal conversion and consequent loss of epidermal stem cells; (ii) the clonogenic ability, growth rate, and long-term proliferative potential are not affected by the new culture system; (iii) when fibrin-cultured autografts bearing stem cells are applied on massive full-thickness burns, the "take" of keratinocytes is high, reproducible, and permanent; and (iv) fibrin allows a significant reduction of the cost

  1. Stacking gels: A method for maximising output for pulsed-field gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Heng See

    2009-01-01

    Full Text Available Pulsed field gel electrophoresis (PFGE, the gold standard of molecular typing methods, has a major disadvantage of an unusually long electrophoretic time. From the original protocol of 6 days, it was modified to 3 days and subsequently to a single day. We describe the procedure of stacking five to six gels one on top of another in order to increase and maximize the output in a shorter time without compromising the resolution and reproducibility. All the variables that affect pulsed field gels during electrophoresis were taken into consideration. We firstly optimized the parameters to be used and secondly determined whether stacking of five to six gels had any effect on the molecular separation during electrophoresis in comparison with a single gel run. DNA preparation, restriction, electrophoresis, staining and gel documentation was carried out based on previously published methods. Gels were analysed using BioNumerics and dice coefficient and unweighted pair group methods were used to generate dendrograms based on 1.5% tolerance values. Identical band profiles and band resolution-separation were seen in the PFGE patterns with single gel and multiple stacking gels. Cluster analysis further strengthened the fact that results from stacking gels were reproducible and comparable with a single gel run. This method of stacking gels saves time and maximizes the output at the same time. The run time for a single gel was about 28 hours, but with six stacked gels the run time was 54 hours compared with 28 x 6 = 168 hours if they were run separately as single gels thus saving time of 67.86%. Beside the big factor of saving time, stacking gels save resources (electricity, reagents, water, chemicals and working time by increasing the sample throughput in a shorter time without compromising on quality of data. But optimization of working parameters is vital depending on the PFGE system used.

  2. Fibrinogen Vicenza and Genova II: two new cases of congenital dysfibrinogenemia with isolated defect of fibrin monomer polymerization and inhibitory activity on normal coagulation.

    Science.gov (United States)

    Rodeghiero, F; Castaman, G C; Dal Belin Peruffo, A; Dini, E; Galletti, A; Barone, E; Gastaldi, G

    1987-06-03

    Two new cases of congenital dysfibrinogenemia are presented in which defective fibrin monomer polymerization and inhibitory activity on normal coagulation were observed. They have been tentatively called fibrinogen Vicenza and Genova II. The first was discovered in a family with mild bleeding diathesis, the second in an asymptomatic family. In almost all reported cases of fibrinogens with defective fibrin monomer polymerization, additional functional or structural defects have been detected. In our cases, on the contrary, detailed investigations failed to show any other abnormality. Fibrinogen Genova II is apparently identical to fibrinogen Baltimore IV, whereas fibrinogen Vicenza is similar to fibrinogen Troyes and Genova I, but also exerts an evident inhibitory activity on normal coagulation and differs from fibrinogen Genova II and Baltimore IV showing a different kinetic pattern of fibrin monomer polymerization.

  3. The Effect of Chondroitin Sulphate and Hyaluronic Acid on Chondrocytes Cultured within a Fibrin-Alginate Hydrogel

    Directory of Open Access Journals (Sweden)

    Christopher J. Little

    2014-09-01

    Full Text Available Osteoarthritis is a painful degenerative joint disease that could be better managed if tissue engineers can develop methods to create long-term engineered articular cartilage tissue substitutes. Many of the tissue engineered cartilage constructs currently available lack the chemical stimuli and cell-friendly environment that promote the matrix accumulation and cell proliferation needed for use in joint cartilage repair. The goal of this research was to test the efficacy of using a fibrin-alginate hydrogel containing hyaluronic acid (HA and/or chondroitin sulphate (CS supplements for chondrocyte culture. Neonatal porcine chondrocytes cultured in fibrin-alginate hydrogels retained their phenotype better than chondrocytes cultured in monolayer, as evidenced by analysis of their relative expression of type II versus type I collagen mRNA transcripts. HA or CS supplementation of the hydrogels increased matrix glycosaminoglycan (GAG production during the first week of culture. However, the effects of these supplements on matrix accumulation were not additive and were no longer observed after two weeks of culture. Supplementation of the hydrogels with CS or a combination of both CS and HA increased the chondrocyte cell population after two weeks of culture. Statistical analysis indicated that the HA and CS treatment effects on chondrocyte numbers may be additive. This research suggests that supplementation with CS and/or HA has positive effects on cartilage matrix production and chondrocyte proliferation in three-dimensional (3D fibrin-alginate hydrogels.

  4. Viscoplastic fracture transition of a biopolymer gel.

    Science.gov (United States)

    Frieberg, Bradley R; Garatsa, Ray-Shimry; Jones, Ronald L; Bachert, John O; Crawshaw, Benjamin; Liu, X Michael; Chan, Edwin P

    2018-06-13

    Physical gels are swollen polymer networks consisting of transient crosslink junctions associated with hydrogen or ionic bonds. Unlike covalently crosslinked gels, these physical crosslinks are reversible thus enabling these materials to display highly tunable and dynamic mechanical properties. In this work, we study the polymer composition effects on the fracture behavior of a gelatin gel, which is a thermoreversible biopolymer gel consisting of denatured collagen chains bridging physical network junctions formed from triple helices. Below the critical volume fraction for chain entanglement, which we confirm via neutron scattering measurements, we find that the fracture behavior is consistent with a viscoplastic type process characterized by hydrodynamic friction of individual polymer chains through the polymer mesh to show that the enhancement in fracture scales inversely with the squared of the mesh size of the gelatin gel network. Above this critical volume fraction, the fracture process can be described by the Lake-Thomas theory that considers fracture as a chain scission process due to chain entanglements.

  5. Microbiology and pathology of fibrinous pericarditis in Danish slaughter pigs

    DEFF Research Database (Denmark)

    Buttenschøn, J.; Friis, N.F.; Aalbaek, B.

    1997-01-01

    The prevalence of fibrinous pericarditis detected at slaughter in Danish slaughter pigs is approximately 0.02 %. The microbiology and pathology of this disorder was studied through 46 field cases collected at slaughter from May 1994 to August 1995. Mycoplasmas (Mycoplasma hyopneumoniae, M...... from the pericardium in three cases. The pericardium was sterile in three cases and contained a low grade mixed flora in two; the latter is believed to be a result of the slaughter procedure rather than an infection. No chlamydiae were found in connection with the microbiological examination...

  6. Selective abrogation of the uPA-uPAR interaction in vivo reveals a novel role in suppression of fibrin-associated inflammation

    DEFF Research Database (Denmark)

    Connolly, Brian M; Choi, Eun Young; Gårdsvoll, Henrik

    2010-01-01

    the interaction between endogenous uPA and uPAR is selectively abrogated, whereas other functions of both the protease and its receptor are retained. Specifically, we introduced 4 amino acid substitutions into the growth factor domain (GFD) of uPA that abrogate uPAR binding while preserving the overall structure...... a principal in vivo role of the uPA-uPAR interaction in cell-associated fibrinolysis critical for suppression of fibrin accumulation and fibrin-associated inflammation and provides a valuable model for further exploration of this multifunctional receptor....

  7. Investigating potential physicochemical errors in polymer gel dosimeters

    International Nuclear Information System (INIS)

    Sedaghat, Mahbod; Lepage, Martin; Bujold, Rachel

    2011-01-01

    Measurement errors in polymer gel dosimetry can originate either during irradiation or scanning. One concern related to the exothermic nature of polymerization reaction was that the heat released in polymer gel dosimeters during irradiation modifies their dose response. In this paper, the effect of heat released from the exothermal polymerization reaction on the dose response of a number of dosimeters was studied. In addition, we investigated whether heat-generated geometric distortion existed in newly proposed gel dosimeters that contain highly thermoresponsive polymers. Our results suggest that despite a significant internal temperature increase in some gel compositions, their dose responses are not affected when oxygen is well expelled mechanically from the gel mixture. We also report on significant pre-irradiation instability in some recently developed polymer gel dosimeters but that geometric distortions were not observed. Data obtained by a set of small calibration vials are compared to those obtained from larger phantoms, and potential physicochemical causes of deviations between them are identified.

  8. Investigating potential physicochemical errors in polymer gel dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Sedaghat, Mahbod; Lepage, Martin [Centre d' imagerie moleculaire de Sherbrooke, Departement de medecine nucleaire et radiobiologie, Universite de Sherbrooke, Sherbrooke, QC (Canada); Bujold, Rachel, E-mail: martin.lepage@usherbrooke.ca [Service de radio-oncologie, Centre hospitalier universitaire de Sherbrooke, Sherbrooke, QC (Canada)

    2011-09-21

    Measurement errors in polymer gel dosimetry can originate either during irradiation or scanning. One concern related to the exothermic nature of polymerization reaction was that the heat released in polymer gel dosimeters during irradiation modifies their dose response. In this paper, the effect of heat released from the exothermal polymerization reaction on the dose response of a number of dosimeters was studied. In addition, we investigated whether heat-generated geometric distortion existed in newly proposed gel dosimeters that contain highly thermoresponsive polymers. Our results suggest that despite a significant internal temperature increase in some gel compositions, their dose responses are not affected when oxygen is well expelled mechanically from the gel mixture. We also report on significant pre-irradiation instability in some recently developed polymer gel dosimeters but that geometric distortions were not observed. Data obtained by a set of small calibration vials are compared to those obtained from larger phantoms, and potential physicochemical causes of deviations between them are identified.

  9. A new step toward the artificial ovary: survival and proliferation of isolated murine follicles after autologous transplantation in a fibrin scaffold.

    Science.gov (United States)

    Luyckx, Valérie; Dolmans, Marie-Madeleine; Vanacker, Julie; Legat, Camille; Fortuño Moya, Cristina; Donnez, Jacques; Amorim, Christiani Andrade

    2014-04-01

    To create an artificial ovary to provide an alternative way of restoring fertility in patients who cannot benefit from transplantation of cryopreserved ovarian tissue due to the threat of reintroducing malignant cells. In vivo experimental study. Gynecology research unit in a university hospital. Six-week-old female NMRI mice. Autografting of isolated preantral follicles and ovarian cells (OCs) encapsulated in two fibrin matrices containing low concentrations of fibrinogen (F; mg/mL) and thrombin (T; IU/mL): F12.5/T1 and F25/T4. Follicular density and development, OC survival and proliferation, inflammatory response, and vascularization. After 1 week, the follicle recovery rate ranged from 30.8% (F25/T4) to 31.8% (F12.5/T1). With both fibrin formulations, all follicles were found to be alive or minimally damaged, as demonstrated by terminal deoxynucleotide transferase-mediated dUTP nick-end labeling assay, and at the growing stage (primary, secondary, and antral follicles), confirmed by Ki67 immunostaining. Isolated OCs also survived and proliferated after grafting, as evidenced by <1% apoptotic cells and a high proportion of Ki67-positive cells. Vessels were found in both fibrin formulations, and the global vascular surface area varied from 1.35% (F25/T4) to 1.88% (F12.5/T1). Numerous CD45-positive cells were also observed in both F25/T4 and F12.5/T1 combinations. The present study is the first to show survival and growth of isolated murine ovarian follicles 1 week after autotransplantation of isolated OCs in a fibrin scaffold. The results indicate that fibrin is a promising candidate as a matrix for the construction of an artificial ovary. Xenotransplantation of isolated human follicles and OCs is the necessary next step to validate these findings. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  10. A Combined In Vitro Imaging and Multi-Scale Modeling System for Studying the Role of Cell Matrix Interactions in Cutaneous Wound Healing.

    Directory of Open Access Journals (Sweden)

    Aribet M De Jesus

    Full Text Available Many cell types remodel the extracellular matrix of the tissues they inhabit in response to a wide range of environmental stimuli, including mechanical cues. Such is the case in dermal wound healing, where fibroblast migrate into and remodel the provisional fibrin matrix in a complex manner that depends in part on the local mechanical environment and the evolving multi-scale mechanical interactions of the system. In this study, we report on the development of an image-based multi-scale mechanical model that predicts the short-term (24 hours, structural reorganization of a fibrin gel by fibroblasts. These predictive models are based on an in vitro experimental system where clusters of fibroblasts (i.e., explants were spatially arranged into a triangular geometry onto the surface of fibrin gels that were subjected to either Fixed or Free in-plane mechanical constraints. Experimentally, regional differences in short-term structural remodeling and cell migration were observed for the two gel boundary conditions. A pilot experiment indicated that these small differences in the short-term remodeling of the fibrin gel translate into substantial differences in long-term (4 weeks remodeling, particularly in terms of collagen production. The multi-scale models were able to predict some regional differences in remodeling and qualitatively similar reorganization patterns for the two boundary conditions. However, other aspects of the model, such as the magnitudes and rates of deformation of gel, did not match the experiments. These discrepancies between model and experiment provide fertile ground for challenging model assumptions and devising new experiments to enhance our understanding of how this multi-scale system functions. These efforts will ultimately improve the predictions of the remodeling process, particularly as it relates to dermal wound healing and the reduction of patient scarring. Such models could be used to recommend patient

  11. Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zeidan, O. A.; Sriprisan, S. I.; Lopatiuk-Tirpak, O.; Kupelian, P. A.; Meeks, S. L.; Hsi, W. C.; Li, Z.; Palta, J. R.; Maryanski, M. J. [M. D. Anderson Cancer Center Orlando, Orlando, Florida 32806 (United States); University of Florida Proton Therapy Institute, Jacksonville, Florida 32206 (United States); MGS Research, Inc., Madison, Connecticut 06443 (United States)

    2010-05-15

    Purpose: The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry. Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.

  12. Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

    International Nuclear Information System (INIS)

    Zeidan, O. A.; Sriprisan, S. I.; Lopatiuk-Tirpak, O.; Kupelian, P. A.; Meeks, S. L.; Hsi, W. C.; Li, Z.; Palta, J. R.; Maryanski, M. J.

    2010-01-01

    Purpose: The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry. Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.

  13. Gel network shampoo formulation and hair health benefits.

    Science.gov (United States)

    Marsh, J M; Brown, M A; Felts, T J; Hutton, H D; Vatter, M L; Whitaker, S; Wireko, F C; Styczynski, P B; Li, C; Henry, I D

    2017-10-01

    The objective of this work was to create a shampoo formula that contains a stable ordered gel network structure that delivers fatty alcohols inside hair. X-ray diffraction (SAXS and WAXS), SEM and DSC have been used to confirm formation of the ordered Lβ gel network with fatty alcohol (cetyl and stearyl alcohols) and an anionic surfactant (SLE1S). Micro-autoradiography and extraction methods using GC-MS were used to confirm penetration of fatty alcohols into hair, and cyclic fatigue testing was used to measure hair strength. In this work, evidence of a stable Lβ ordered gel network structure created from cetyl and stearyl alcohols and anionic surfactant (SLE1S) is presented, and this is confirmed via scanning electron microscopy images showing lamella layers and differential scanning calorimetry (DSC) showing new melting peaks vs the starting fatty alcohols. Hair washed for 16 repeat cycles with this shampoo showed penetration of fatty alcohols from the gel network into hair as confirmed by a differential extraction method with GC-MS and by radiolabelling of stearyl alcohol and showing its presence inside hair cross-sections. The gel network role in delivering fatty alcohol inside hair is demonstrated by comparing with a shampoo with added fatty alcohol not in an ordered gel network structure. The hair containing fatty alcohol was measured via the Dia-stron cyclic fatigue instrument and showed a significantly higher number of cycles to break vs control. The formation of a stable gel network was confirmed in the formulated shampoo, and it was demonstrated that this gel network is important to deliver cetyl and stearyl alcohols into hair. The presence of fatty alcohol inside hair was shown to deliver a hair strength benefit via cyclic fatigue testing. © 2017 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  14. Energy-Efficient Bioalcohol Recovery by Gel Stripping

    Science.gov (United States)

    Godbole, Rutvik; Ma, Lan; Hedden, Ronald

    2014-03-01

    Design of energy-efficient processes for recovering butanol and ethanol from dilute fermentations is a key challenge facing the biofuels industry due to the high energy consumption of traditional multi-stage distillation processes. Gel stripping is an alternative purification process by which a dilute alcohol is stripped from the fermentation product by passing it through a packed bed containing particles of a selectively absorbent polymeric gel material. The gel must be selective for the alcohol, while swelling to a reasonable degree in dilute alcohol-water mixtures. To accelerate materials optimization, a combinatorial approach is taken to screen a matrix of copolymer gels having orthogonal gradients in crosslinker concentration and hydrophilicity. Using a combination of swelling in pure solvents, the selectivity and distribution coefficients of alcohols in the gels can be predicted based upon multi-component extensions of Flory-Rehner theory. Predictions can be validated by measuring swelling in water/alcohol mixtures and conducting h HPLC analysis of the external liquid. 95% + removal of butanol from dilute aqueous solutions has been demonstrated, and a mathematical model of the unsteady-state gel stripping process has been developed. NSF CMMI Award 1335082.

  15. Comparison of vasovasostomy with conventional microsurgical suture and fibrin adhesive in rats

    Directory of Open Access Journals (Sweden)

    Wilson F. Busato Junior

    2007-12-01

    Full Text Available OBJECTIVE: Microsurgical procedures are currently the gold standard for vasovasostomy with excellent results, but it takes an increased operative time demanding special training and experience in microsurgery. The objective of this study is to reach the same results with reduced operative time. MATERIALS AND METHODS: Male adults Wistar rats were divided into 3 groups: I 20 rats in control group, II 20 with conventional one-layer microsuture and III 20 with fibrin glue. After four weeks each rat was left for two weeks with two female rats. RESULTS: The fertility rates were 80% in group I, 70% in group II and 65% in group III (p > 0.05. In group II granuloma was found in 75% of the rats, while in group III in 85% (p 0.05. Overall operative time was 41.7 ± 2.49 and 28.55 ± 1.14 minutes in groups II and III (p < 0.05 and the time to anastomosis of 24.6 ± 1.8 and 9.35 ± 0.78 minutes (p < 0.05, respectively. CONCLUSIONS: We can conclude that vasovasostomy with fibrin adhesive has the same results of the conventional microsurgery technique but with a reduced operative time and a simplified procedure.

  16. [Research of repairing rabbit knee joint cartilage defect by compound material of fibrin glue and decalcified bone matrix (DBM) and chondrocytes].

    Science.gov (United States)

    He, Jie; Yang, Xiang; Yue, Peng-ju; Wang, Guan-yu; Guo, Ting; Zhao, Jian-ning

    2009-07-01

    To investigate the feasibility and effectivity of using compound material of fibrin glue and DBM as scaffolds for cartilage tissue engineering. Chondrocytes isolated from articular cartilage were seeded into prepared scaffolds, after incubation for 4 weeks in vitro. Chondrocytes and fibrin glue and DBM constructs were implanted in the joint cave of rabbit. The specimens were excised at the 4th, 8th, 12th week, examined grossly analyzed by haematoxylin cosine, toluidine blues staining and type II collagen immunohistochemistry reaction. Wakitani score was counted to evaluate the repairing effect. Grossly analysis showed some ivory tissue filled the caves after 4 weeks and the caves were full filled with smooth surface after 12 weeks. The microscope showed a good deal of chondrocytes appeared after 8 weeks and more type II collagen than 4 weeks. Twelve weeks later, cartilage lacuna could be observed. The cells arrangement and the amount of type II collagen both showed the same as the natural one. Complicated material of fibrin glue and DBM as scaffolds can be used as scaffolds for cartilage tissue engineering.

  17. Tomotherapy dose distribution verification using MAGIC-f polymer gel dosimetry

    International Nuclear Information System (INIS)

    Pavoni, J. F.; Pike, T. L.; Snow, J.; DeWerd, L.; Baffa, O.

    2012-01-01

    Purpose: This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. Methods: A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treatment was delivered by a TomoTherapy equipment. Dose distribution was evaluated by the R2 distribution measured in magnetic resonance imaging. Results: A high similarity was found by overlapping of isodoses of the dose distribution measured with the gel and expected by the treatment planning system (TPS). Another analysis was done by comparing the relative absorbed dose profiles in the measured and in the expected dose distributions extracted along indicated lines of the volume and the results were also in agreement. The gamma index analysis was also applied to the data and a high pass rate was achieved (88.4% for analysis using 3%/3 mm and of 96.5% using 4%/4 mm). The real three-dimensional analysis compared the dose-volume histograms measured for the planning volumes and expected by the treatment planning, being the results also in good agreement by the overlapping of the curves. Conclusions: These results show that MAGIC-f gel is a promise for tridimensional dose distribution measurements.

  18. Tomotherapy dose distribution verification using MAGIC-f polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Pavoni, J. F.; Pike, T. L.; Snow, J.; DeWerd, L.; Baffa, O. [Departamento de Fisica, Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto-Universidade de Sao Paulo, Av. Bandeirantes, 3900 - CEP 14040-901 - Bairro Monte Alegre - Ribeirao Preto, SP (Brazil); Medical Radiation Research Center, Department of Medical Physics, University of Wisconsin, 1111 Highland Avenue, B1002 WIMR, Madison, Wisconsin 53705-2275 (United States); Departamento de Fisica, Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto-Universidade de Sao Paulo, Av. Bandeirantes, 3900 - CEP 14040-901 - Bairro Monte Alegre - Ribeirao Preto, SP (Brazil)

    2012-05-15

    Purpose: This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. Methods: A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treatment was delivered by a TomoTherapy equipment. Dose distribution was evaluated by the R2 distribution measured in magnetic resonance imaging. Results: A high similarity was found by overlapping of isodoses of the dose distribution measured with the gel and expected by the treatment planning system (TPS). Another analysis was done by comparing the relative absorbed dose profiles in the measured and in the expected dose distributions extracted along indicated lines of the volume and the results were also in agreement. The gamma index analysis was also applied to the data and a high pass rate was achieved (88.4% for analysis using 3%/3 mm and of 96.5% using 4%/4 mm). The real three-dimensional analysis compared the dose-volume histograms measured for the planning volumes and expected by the treatment planning, being the results also in good agreement by the overlapping of the curves. Conclusions: These results show that MAGIC-f gel is a promise for tridimensional dose distribution measurements.

  19. Evaluation of Fibrin-Based Interpenetrating Polymer Networks as Potential Biomaterials for Tissue Engineering

    Directory of Open Access Journals (Sweden)

    Olfat Gsib

    2017-12-01

    Full Text Available Interpenetrating polymer networks (IPNs have gained great attention for a number of biomedical applications due to their improved properties compared to individual components alone. In this study, we investigated the capacity of newly-developed naturally-derived IPNs as potential biomaterials for tissue engineering. These IPNs combine the biologic properties of a fibrous fibrin network polymerized at the nanoscale and the mechanical stability of polyethylene oxide (PEO. First, we assessed their cytotoxicity in vitro on L929 fibroblasts. We further evaluated their biocompatibility ex vivo with a chick embryo organotypic culture model. Subcutaneous implantations of the matrices were subsequently conducted on nude mice to investigate their biocompatibility in vivo. Our preliminary data highlighted that our biomaterials were non-cytotoxic (viability above 90%. The organotypic culture showed that the IPN matrices induced higher cell adhesion (across all the explanted organ tissues and migration (skin, intestine than the control groups, suggesting the advantages of using a biomimetic, yet mechanically-reinforced IPN-based matrix. We observed no major inflammatory response up to 12 weeks post implantation. All together, these data suggest that these fibrin-based IPNs are promising biomaterials for tissue engineering.

  20. Chromatin structure influence of DNA damage measurements by four assays: pulsed- and constant-field gel electrophoresis, DNA precipitation and non-denaturing filter elution

    International Nuclear Information System (INIS)

    Wlodek, D.; Olive, P.L.

    1996-01-01

    The of elution of DNA during non-denaturing filter elution (NFE) often correlates with cell sensitivity to radiation. The elution rate is influenced by two cellular factors: chromatin structure and the number of DNA-strand breaks (DSBs) produced in an intact cell by ionizing radiation. To determine which of the above factors is relevant to cell radiosensitivity, four assays were used to measure induction of DNA damage in three cell lines varying in radiosensitivity (V79, CHO, and L5178Y-R). Each of the assays, neutral filter elution (NFE), DNA precipitation, constant (CFGE) and pulsed field gel electrophoresis (PFGE) have different physical basis for DNA damage measurement and might be differently affected by chromatin structure. Three of the methods used to measure DNA double-strand breaks gave different results: NFE was dependent on cell type and location of DNA relative to the replication fork, gel electrophoresis was independent of cell type but was affected by proximity to the replication fork, and the precipitation assay was independent of both cell type and replication status. Pulsed field gel electrophoresis produced the same results and constant field gel electrophoresis for 3 cell lines examined. Only NFE showed differences in sensitivity which correlated with cell survival following irradiation. The results suggest that three is the same initial amount of DSBs in cells from all three lines and that the sensitivity to radiation is determined by some additional factors, probably chromatin structure. (author). 18 refs, 5 figs

  1. Electrophoresis of DNA in agarose gels, polyacrylamide gels and in free solution

    Science.gov (United States)

    Stellwagen, Nancy C.

    2009-01-01

    This review describes the electrophoresis of curved and normal DNA molecules in agarose gels, polyacrylamide gels and in free solution. These studies were undertaken to clarify why curved DNA molecules migrate anomalously slowly in polyacrylamide gels but not in agarose gels. Two milestone papers are cited, in which Ferguson plots were used to estimate the effective pore size of agarose and polyacrylamide gels. Subsequent studies on the effect of the electric field on agarose and polyacrylamide gel matrices, DNA interactions with the two gel matrices, and the effect of curvature on the free solution mobility of DNA are also described. The combined results suggest that the anomalously slow mobilities observed for curved DNA molecules in polyacrylamide gels are due primarily to preferential interactions of curved DNAs with the polyacrylamide gel matrix; the restrictive pore size of the matrix is of lesser importance. In free solution, DNA mobilities increase with increasing molecular mass until leveling off at a plateau value of (3.17 ± 0.01) × 10-4 cm2/Vs in 40 mM Tris-acetate-EDTA buffer at 20°C. Curved DNA molecules migrate anomalously slowly in free solution as well as in polyacrylamide gels, explaining why the Ferguson plots of curved and normal DNAs containing the same number of base pairs extrapolate to different mobilities at zero gel concentration. PMID:19517510

  2. The effect of sibutramine, a serotonin-norepinephrine reuptake inhibitor, on platelets and fibrin networks of male Sprague-Dawley rats: a descriptive study.

    Science.gov (United States)

    van der Schoor, Ciska; Oberholzer, Hester Magdalena; Bester, Megan Jean; van Rooy, Mia-Jeanne

    2014-12-01

    Sibutramine is used in the treatment of obesity due to its ability to influence feelings of hunger and satiety by inhibiting the re-uptake of serotonin and noradrenalin in the central nervous system (CNS). Sibutramine use has been associated with numerous adverse events in particular cardiovascular complications possibly due to the formation of thrombi. This ultrastructural descriptive study investigated the effect of sibutramine on blood coagulation, specifically the effect on morphology of platelets and fibrin networks using scanning electron microscopy. Male Sprague-Dawley rats treated with either a recommended therapeutic dose [low dosage 1.32 mg/kg] or a toxicological higher dose [high dosage 13.2 mg/kg] of sibutramine for 28 days were used and compared to control animals. Blood samples were collected and plasma smears were prepared for platelet evaluation. Following the addition of thrombin to the plasma samples, the morphology of the fibrin clots was evaluated. Platelet evaluation by scanning electron microscopy revealed morphology typical of a prothrombotic state with a characteristic excessive platelet activation in both low-dose (LD) and high-dose (HD) rats. The fibrin clots of sibutramine-treated rats, LD and HD revealed fused thick fibers with thin fibers forming a net-like structure over the thick fibers which differ considerably from the organized structure of the control animals. It can be concluded that sibutramine alters the ultrastructure of platelets and fibrin networks creating a prothrombotic state.

  3. Clinical and morphological evaluation of snake venom derived fibrin glue on the tendon healing in dogs

    Directory of Open Access Journals (Sweden)

    G. C. Ferraro

    2005-12-01

    Full Text Available The aim of this study was to evaluate the effect of snake venom derived fibrin glue on the healing of the deep digital flexor tendon, during three periods. The tendon of the 2nd digit of 30 thoracic limbs of dogs was partially sectioned for glue application. Biopsies were performed 7, 15, and 30 days post surgery for the clinical and morphological study of tendons. Analysis of the results showed that 73.3% of the tendons showed stump retraction and 16.6% moderate to excessive adherence, which affected sliding. There was a significant difference in the number of inflammatory cells among the three studied periods, being the highest on day 15. The morphological analysis revealed a typical tendon healing process with a lower level of inflammation in the acute phase, facilitating the cicatricial maturation phase. Snake venom derived fibrin glue promotes the healing in dog flexor tendon.

  4. Interaktion mellem warfarin og oral miconazol-gel

    DEFF Research Database (Denmark)

    Ogard, C G; Vestergaard, Henrik

    2000-01-01

    We report a case of a 76 year-old woman who had been taking warfarin for seven years because of relapsing deep venous thrombosis. Her daily maintenance dose was 5 mg. Monthly measurements of international normalised ratio (INR) were stable between 2-3. She developed oral candidiasis and miconazole...... gel was prescribed. One week later she developed bleeding gums. Eight days later she was admitted to the hospital with haematuria. INR was > 10. Warfarin and the miconazole gel were withdrawn. She was treated with phytonadione. INR normalised after four days and she continued warfarin treatment....... Caution should be exercised whenever the combination of warfarin and miconazole gel are prescribed....

  5. Efficacy of Platelet-Rich Fibrin After Mandibular Third Molar Extraction: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Al-Hamed, Faez Saleh; Tawfik, Mohamed Abdel-Monem; Abdelfadil, Ehab; Al-Saleh, Mohammed A Q

    2017-06-01

    To assess the effect of platelet-rich fibrin (PRF) on the healing process of the alveolar socket after surgical extraction of the mandibular third molars. PubMed, the Cochrane Central Register of Controlled Trials, Scopus, and relevant journals were searched using a combination of specific keywords ("platelet-rich fibrin," "oral surgery," and "third molar"). The final search was conducted on November 2, 2015. Randomized controlled clinical trials, as well as controlled clinical trials, aimed at comparing the effect of PRF versus natural healing after extraction of mandibular third molars were included. Five randomized controlled trials and one controlled clinical trial were included. There were 335 extractions (168 with PRF and 167 controls) in 183 participants. Considerable heterogeneity in study characteristics, outcome variables, and estimated scales was observed. Positive results were generally recorded for pain, trismus, swelling, periodontal pocket depth, soft tissue healing, and incidence of localized osteitis, but not in all studies. However, no meta-analysis could be conducted for such variables because of the different measurement scales used. The qualitative and meta-analysis results showed no significant improvement in bone healing with PRF-treated sockets compared with the naturally healing sockets. Within the limitations of the available evidence, PRF seems to have no beneficial role in bone healing after extraction of the mandibular third molars. Future standardized randomized controlled clinical trials are required to estimate the effect of PRF on socket regeneration. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Different Applications of Rheological Techniques in Studies of Physical Gels

    DEFF Research Database (Denmark)

    Hvidt, Søren

    of associating protein filaments with the characteristic function of individual filaments. The proteins enable the cell to regulate the mechanical properties of the cell by sol-gel transition and a variety of crosslinking reactions. In the food industry texture of products are regulated by addition of gel......, respectively, are particularly useful for investigating slow motions in gels and long-time properties. An example of how these different techniques have been used to investigate the rheological properties of sputum [4] will be discussed. The results demonstrate that sputum is a viscoelastic material...... are dominated by repulsive interactions between micelles, and oscillatory measurements allow a determination of the repulsive potential between micelles. Oscillatory bulk modulus measurements have been used to determine the dynamics of unimer-micelle motions. The strain properties of physical gels are of major...

  7. A gel probe equilibrium sampler for measuring arsenic porewater profiles and sorption gradients in sediments: II. Field application to Haiwee reservoir sediment

    Science.gov (United States)

    Campbell, K.M.; Root, R.; O'Day, P. A.; Hering, J.G.

    2008-01-01

    Arsenic (As) geochemistry and sorption behavior were measured in As- and iron (Fe)-rich sediments of Haiwee Reservoir by deploying undoped (clear) polyacrylamide gels and hydrous ferric oxide (HFO)-doped gels in a gel probe equilibrium sampler, which is a novel technique for directly measuring the effects of porewater composition on As adsorption to Fe oxides phases in situ. Arsenic is deposited at the sediment surface as As(V) and is reduced to As(III) in the upper layers of the sediment (0-8 cm), but the reduction of As(V) does not cause mobilization into the porewater. Dissolved As and Fe concentrations increased at depth in the sediment column driven by the reductive dissolution of amorphous Fe(III) oxyhydroxides and conversion to a mixed Fe(II, III) green rust-type phase. Adsorption of As and phosphorous (P) onto HFO-doped gels was inhibited at intermediate depths (10-20 cm), possibly due to dissolved organic or inorganic carbon, indicating that dissolved As concentrations were at least partially controlled by porewater composition rather than surface site availability. In sediments that had been recently exposed to air, the region of sorption inhibition was not observed, suggesting that prior exposure to air affected the extent of reductive dissolution, porewater chemistry, and As adsorption behavior. Arsenic adsorption onto the HFO-doped gels increased at depths >20 cm, and the extent of adsorption was most likely controlled by the competitive effects of dissolved phosphate. Sediment As adsorption capacity appeared to be controlled by changes in porewater composition and competitive effects at shallower depths, and by reductive dissolution and availability of sorption sites at greater burial depths. ?? 2008 American Chemical Society.

  8. Laser CT evaluation on normoxic PAGAT gel dosimeter

    International Nuclear Information System (INIS)

    Kumar, D S; Samuel, E J J; Watanabe, Y

    2013-01-01

    Optical computed tomography has been shown to be a potentially useful imaging tool for the radiation therapy physicists. In radiation therapy, researchers have used optical CT for the readout of 3D dosimeters. The purpose of this paper is to describe the initial evaluation of a newly fabricated laser CT scanner for 3D gel dosimetry which works using the first generation principle. A normoxic PAGAT (Polyacrylamide Gelatin and Tetrakis) gel is used as a dosimeter for this analysis. When a laser passes through the gel phantom, absorption and scattering of photon take place. The optical attenuation coefficient of the laser can be obtained by measuring its intensity after passing through the gel by a sensor. The scanner motion is controlled by a computer program written in Microsoft Visual C++. Reconstruction and data analysis on the irradiated gel phantom is performed by suitable algorithm using Matlab software.

  9. Optical CT evaluation on normoxic polymer gel dosimeter

    International Nuclear Information System (INIS)

    Samuel, E. James Jebaseelan

    2013-01-01

    Optical computed tomography has been shown to be a potentially useful imaging tool for the radiation therapy physicists. In radiation therapy, researchers have used optical CT for the readout of 3D dosimeters. The purpose of this paper is to explicate the initial evaluation of a newly fabricated laser CT scanner for '3D gel dosimetry' which works in the first generation principle. The normoxic PAGAT (Polyacrylamide Gelatin and Tetrakis) gel is used as a dosimeter for this analysis. When laser passes through this gel phantom, absorption and scattering of photon take place. The optical attenuation coefficient of the laser can be obtained by measuring its intensity after passing through the gel by a sensor.The scanner motion is controlled by the program written in Microsoft Visual C++. Reconstruction and data analysis on the irradiated gel phantom is performed by suitable algorithm using Matlab software. (author)

  10. Transport Phenomena in Gel

    Directory of Open Access Journals (Sweden)

    Masayuki Tokita

    2016-05-01

    Full Text Available Gel becomes an important class of soft materials since it can be seen in a wide variety of the chemical and the biological systems. The unique properties of gel arise from the structure, namely, the three-dimensional polymer network that is swollen by a huge amount of solvent. Despite the small volume fraction of the polymer network, which is usually only a few percent or less, gel shows the typical properties that belong to solids such as the elasticity. Gel is, therefore, regarded as a dilute solid because its elasticity is much smaller than that of typical solids. Because of the diluted structure, small molecules can pass along the open space of the polymer network. In addition to the viscous resistance of gel fluid, however, the substance experiences resistance due to the polymer network of gel during the transport process. It is, therefore, of importance to study the diffusion of the small molecules in gel as well as the flow of gel fluid itself through the polymer network of gel. It may be natural to assume that the effects of the resistance due to the polymer network of gel depends strongly on the network structure. Therefore, detailed study on the transport processes in and through gel may open a new insight into the relationship between the structure and the transport properties of gel. The two typical transport processes in and through gel, that is, the diffusion of small molecules due to the thermal fluctuations and the flow of gel fluid that is caused by the mechanical pressure gradient will be reviewed.

  11. Non-stationary heat transfer in gels applied to biotehnology

    Directory of Open Access Journals (Sweden)

    Pokusaev Boris

    2017-01-01

    Full Text Available Unsteady heat transfer in agarose gels of various concentrations was studied in order to make a breakthrough in the technology of 3-D additive bioprinting. Data on the kinetics of the phase transformation was obtained using spectroscopy as a function of temperature during the formation of agarose hydrogel. The dynamics of aging was investigated for gels of different densities. The time dependence of the structural changes was obtained. Particular attention was paid to the changes in the structure of the gel due to the processes of evaporation of the liquid during the gel formation and during long-term storage. Experiments were performed to determine the dynamics of the temperature fields simultaneously with heat flux measurements during the formation of agarose gels from different initial concentrations. A technique based on experimental data for the computations of the thermophysical coefficients of agarose gels was developed.

  12. Comparative study of nano copper aluminate spinel prepared by sol–gel and modified sol–gel techniques: Structural, electrical, optical and catalytic studies

    International Nuclear Information System (INIS)

    Kumar, R. Thinesh; Suresh, P.; Selvam, N. Clament Sagaya; Kennedy, L. John; Vijaya, J. Judith

    2012-01-01

    Highlights: ► A modified sol–gel method for the preparation of nano CuAl 2 O 4 spinel using ethylenediamine was studied. ► Role of ethylenediamine in enhancing the structural, electrical, optical and catalytic properties of copper aluminate is highlighted. ► Effect of preparation method on the activity and selectivity of the samples on the oxidation of benzyl alcohol by CuAl 2 O 4 is studied. - Abstract: The effect of ethylenediamine addition in the sol–gel method for the preparation of nano CuAl 2 O 4 spinel for the enhancement in their structural, electrical, optical and catalytic properties was investigated. The samples were prepared by two different methods: sol–gel and modified sol–gel technique using ethylenediamine. X-ray diffraction (XRD), Fourier transform infrared spectra (FT-IR), scanning electron microscopy (SEM), high resolution-transmission electron microscopy (HR-TEM), energy dispersive X-ray analysis (EDX), nitrogen adsorption/desorption isotherms, temperature dependent conductance measurements, thermoelectric power (TEP) measurements and UV–visible diffuse reflectance (UV–vis-DRS) spectra were used to characterize the samples prepared. CuAl 2 O 4 prepared by modified sol–gel technique was found to possess a higher surface area, lower crystallite size, lower activation energy and high porosity than the one prepared by sol–gel method which in turn lead to the improved performance of it towards the selective oxidation of benzyl alcohol to benzaldehyde. Effect of solvent on the catalytic oxidation of benzyl alcohol by the nano CuAl 2 O 4 prepared by modified sol–gel technique was also investigated.

  13. Noninvasive Measurement of EKG Properties of 3D Artificial Heart Muscle

    Directory of Open Access Journals (Sweden)

    Betsy H. Salazar

    2017-06-01

    Full Text Available Developing and testing a custom fabricated 16-electrode noninvasive direct contact system was necessary to assess the electrical properties of bioengineered heart muscle and to further evaluate the efficacy of cardiac constructs. By culturing neonatal rat primary cardiac cells on a fibrin gel, we constructed 3D artificial heart muscle (3D-AHM, as described in previous studies, which were used in validating this novel system. Electrical and mechanical functional assessment of the tissues was performed, which yielded contractile forces of the tissues, electrical field potential characteristics, and tissue conduction velocities (CV (20–170 cm/s. Immunohistological evaluation revealed the formation of cardiac tissue structures and cardiomyocyte proliferation. EKG data analysis also yielded time delays between signals in the range of 0–38 ms with electrical maps showing some evidence of synchronous contraction within the fabricated tissues. This study demonstrates the effectiveness and practicality of our novel EKG measuring system to acquire distinct electrical metrics of 3D-AHM, which will aid in increasing the viability and applicability of cardiac tissue constructs.

  14. Acute fibrinous organising pneumonia: a manifestation of trimethoprim-sulfamethoxazole pulmonary toxicity.

    Science.gov (United States)

    Jamous, Fady; Ayaz, Syed Zain; Choate, Jacquelyn

    2014-10-29

    A 50-year-old man was treated with trimethoprim-sulfamethoxazole (TMP-SMX) for acute arthritis of his right big toe. Within a few days, he developed dyspnoea, hypoxaemia and diffuse pulmonary infiltrates. Symptoms improved with discontinuation of the antibiotic but worsened again with its reintroduction. An open lung biopsy was performed. We describe the workup performed and the factors that pointed to a final diagnosis of TMP-SMX-related pulmonary toxicity in the form of acute fibrinous organising pneumonia. 2014 BMJ Publishing Group Ltd.

  15. Insights into gelation kinetics and gel front migration in cation-induced polysaccharide hydrogels by viscoelastic and turbidity measurements: Effect of the nature of divalent cations.

    Science.gov (United States)

    Huynh, Uyen T D; Chambin, Odile; du Poset, Aline Maire; Assifaoui, Ali

    2018-06-15

    Polysaccharide-based hydrogels were prepared by the diffusion of various divalent cations (X 2+ ) into the polygalacturonate (polyGal) solution through a dialysis membrane. The diffusion of various divalent cations (Mg 2+ , Ca 2+ , Zn 2+ and Ba 2+ ) was investigated. The polyGal gel growth was studied as a function of the initial cation concentration by both viscoelastic and turbidity measurements. We have demonstrated for the first time that the determination of the spatiotemporal variation of turbidity during the gelation process allowed to study the gel front migration. For Ca-polyGal, Zn-polyGal and Ba-polyGal, the gel front migration was characterized by the presence of a peak at the sol/gel interface. This peak was not observed in the case of Mg-polyGal where the gel was not formed. The apparent diffusion coefficient of the gel front (D app ) which was calculated from the evolution of this peak increased when the initial cation concentration was increased. Moreover, we have suggested a gelation mechanism based on the presence of a threshold molar ratio R* (=[X 2+ ]/[Galacturonic unit]) in which some point-like crosslinks are precursors of the formation of dimers and multimers inducing the contraction of the gel and thus the formation of the gel front. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry

    International Nuclear Information System (INIS)

    MacDougall, N.D.; Pitchford, W.G.; Smith, M.A.

    2002-01-01

    1998 Radiother. Oncol. 48 283-91, Farajollahi et al 2000 Br. J. Radiol. 72 1085-92, McJury et al 1999b Phys. Med. Biol. 44 2431-44, Murphy et al 2000b Phys. Med. Biol. 45 835-45, Oldham et al 2001 Med. Phys. 28 1436-45) and 5% for Fricke gel (Chan and Ayyangar 1995b Med. Phys. 22 1171-5). Evidence also points to accuracy worsening at lower dose levels for both gels. The precision data should be viewed with caution as repeated MR measurements were not performed with the same samples. The only precision data for Fricke gels was 1.5% (Johansson Back et al 1998 Phys. Med. Biol. 43 261-76), but for zero dose. In conclusion, despite the amount of published data, sparse research has been undertaken which provides clear evidence of the accuracy and precision for both gels. That which has been published has used higher doses than would be routine in radiotherapy. The basic radiation dosimeter qualities of accuracy and precision have yet to be fully quantified for polymer and Fricke gels at clinically relevant dose levels. (author)

  17. Platelet rich fibrin - a novel acumen into regenerative endodontic therapy

    Directory of Open Access Journals (Sweden)

    Kavita Hotwani

    2014-02-01

    Full Text Available Research into regenerative dentistry has added impetus onto the field of molecular biology. It can be documented as a prototype shift in the therapeutic armamentarium for dental disease. Regenerative endodontic procedures are widely being added to the current armamentarium of pulp therapy procedures. The regenerative potential of platelets has been deliberated. A new family of platelet concentrates called the platelet rich fibrin (PRF has been recently used by several investigators and has shown application in diverse disciplines of dentistry. This paper is intended to add light on the various prospects of PRF and clinical insights to regenerative endodontic therapy.

  18. Characterization of long-term dose stability of N-isopropylacrylamide polymer gel dosimetry

    International Nuclear Information System (INIS)

    Chang, Y.J.; Central Taiwan University of Science and Technology, Taichung City, Taiwan, ROC; Chen, C.H.; Hsieh, B.T.

    2014-01-01

    In this study, the detailed characteristics, including spatial uniformity, dose distributions, inter-batch variability, reproducibility, and long-term temporal stability, of N-isopropylacrylamide (NIPAM) polymer gel dosimeter were investigated. A commercial 10x fast optical computed tomography scanner (OCTOPUS TM -10×, MGS Research, Inc., Madison, CT, USA) was used to measure NIPAM polymer gel dosimeter. A cylindrical NIPAM gel phantom that measured 10 cm × 10 cm was irradiated via a single-field treatment plan with a field size of 4 cm × 4 cm. The maximum standard deviation of spatial uniformity for NIPAM gel was less than 0.29 %. The average standard deviation among the three batches of gel dosimeters was less than 1 %. The gamma pass rate could reach as high as 96.76 % when a 3 % dose difference and a 3 mm dose-to-agreement criteria were used. The long-term measurement of irradiated NIPAM gel dosimeter indicated that the dose maps attained a gradually stable value 15 h post-irradiation and remained stable until 72 h post-irradiation. The gamma pass rate could achieve a maximum value between 24 and 72 h post-irradiation. The edge enhancement effect that occurred around the irradiated region was observed 72 h post-irradiation. Thus, the results from this study suggest that NIPAM gel dosimeter should be measured approximately 24 h post-irradiation to reduce the occurrence of the edge enhancement effect. (author)

  19. Assessment of Pain and Quality of Life in Lichtenstein Hernia Repair Using a New Monofilament PTFE Mesh: Comparison of Suture vs. Fibrin-Sealant Mesh Fixation.

    Science.gov (United States)

    Fortelny, René H; Petter-Puchner, Alexander H; Redl, Heinz; May, Christopher; Pospischil, Wolfgang; Glaser, Karl

    2014-01-01

    Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e., the Infinit(®) mesh by W. L. Gore & Associates. This study was designed as a controlled prospective single-center two-cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin-sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e., seroma, infection), pain, and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year. Significantly, less postoperative pain was reported in the fibrin-sealant group compared to the suture group at 6 weeks (P = 0.035), 6 months (P = 0.023), and 1 year (P = 0.011) postoperatively. Additionally, trends toward a higher postoperative quality of life, a faster surgical procedure, and a shorter hospital stay were seen in the fibrin-sealant group. Fibrin-sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair.

  20. Assessment of pain and quality of life in Lichtenstein hernia repair using a new monofilament PTFE mesh: comparison of suture vs. fibrin sealant mesh fixation

    Directory of Open Access Journals (Sweden)

    René H Fortelny

    2014-11-01

    Full Text Available Background: Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e. the Infinit® mesh by W. L. Gore & Associates. Methods: This study was designed as a controlled prospective single-centre two cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e. seroma, infection, pain and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year.Results: Significantly less postoperative pain was reported in the fibrin sealant group compared to the suture group at 6 weeks (P=0.035, 6 months (P=0.023 and 1 year (P=0.011 postoperatively. Additionally trends towards a higher postoperative quality of life, a faster surgical procedure and a shorter hospital stay were seen in the fibrin sealant group.Conclusion: Fibrin sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair.

  1. Characteristics of an autologous leukocyte and platelet-rich fibrin patch intended for the treatment of recalcitrant wounds

    DEFF Research Database (Denmark)

    Lundquist, Rasmus; Holmstrøm, Kim; Clausen, Christian

    2012-01-01

    We have investigated the physical, biochemical, and cellular properties of an autologous leukocyte and platelet-rich fibrin patch. This was generated in an automated device from a sample of a patient's blood at the point of care. Using microscopy, cell counting, enzyme-linked immunosorbent assay...... of chronic wound fluid. By comparison with traditional platelet-rich plasma, differences in immune components were found. The relevance of these findings was assessed by showing a mitogenic and migratory effect on cultured human dermal fibroblasts. Further, we showed that fibrocytes, a cell type important......, antibody arrays, and cell culture assays, we show that the patch is a three-layered membrane comprising a fibrin sheet, a layer of platelets, and a layer of leukocytes. Mean recovery of platelets from the donated blood was 98% (±95%CI 0.8%). Mean levels of platelet-derived growth factor AB, human...

  2. Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy.

    Science.gov (United States)

    Low, D A; Dempsey, J F; Venkatesan, R; Mutic, S; Markman, J; Mark Haacke, E; Purdy, J A

    1999-08-01

    BANG gel (MGS Research, Inc., Guilford, CT) has been evaluated for measuring intensity-modulated radiation therapy (IMRT) dose distributions. Treatment plans with target doses of 1500 cGy were generated by the Peacock IMRT system (NOMOS Corp., Sewickley, PA) using test target volumes. The gels were enclosed in 13 cm outer diameter cylindrical glass vessels. Dose calibration was conducted using seven smaller (4 cm diameter) cylindrical glass vessels irradiated to 0-1800 cGy in 300 cGy increments. Three-dimensional maps of the proton relaxation rate R2 were obtained using a 1.5 T magnetic resonance imaging (MRI) system (Siemens Medical Systems, Erlangen, Germany) and correlated with dose. A Hahn spin echo sequence was used with TR = 3 s, TE = 20 and 100 ms, NEX = 1, using 1 x 1 x 3 mm3 voxels. The MRI measurements were repeated weekly to identify the gel-aging characteristics. Ionization chamber, thermoluminescent dosimetry (TLD), and film dosimetry measurements of the IMRT dose distributions were obtained to compare against the gel results. The other dosimeters were used in a phantom with the same external cross-section as the gel phantom. The irradiated R2 values of the large vessels did not precisely track the smaller vessels, so the ionization chamber measurements were used to normalize the gel dose distributions. The point-to-point standard deviation of the gel dose measurements was 7.0 cGy. When compared with the ionization chamber measurements averaged over the chamber volume, 1% agreement was obtained. Comparisons against radiographic film dose distribution measurements and the treatment planning dose distribution calculation were used to determine the spatial localization accuracy of the gel and MRI. Spatial localization was better than 2 mm, and the dose was accurately determined by the gel both within and outside the target. The TLD chips were placed throughout the phantom to determine gel measurement precision in high- and low-dose regions. A

  3. Electrochemical behavior of ionically crosslinked polyampholytic gel electrolytes

    International Nuclear Information System (INIS)

    Chen Wanyu; Tang Haitao; Ou Ziwei; Wang Hong; Yang Yajiang

    2007-01-01

    An ionic complex of anionic and cationic monomers was obtained by protonation of (N,N-diethylamino)ethylmethacrylate (DEA) with acrylic acid (AAc). Free radical copolymerization of the ionic complex and acrylamide (AAm), yielded the ionically crosslinked polyampholytic gel electrolytes [poly(AAc-DEA-AAm), designated as PADA] using two types of organic solvents containing a lithium salt. The PADA gel electrolyte exhibited good thermal stability shown by the DSC thermogram. The impedance analysis at temperatures ranging from -30 to 75 deg. C indicated that the ionic conductivities of the PADA gel electrolytes were rather close to those of liquid electrolytes. The temperature dependence of the ionic conductivities was found to be in accord with the Arrhenius equation. Moreover, the ionic conductivities of PADA gel electrolytes increased with an increase of the molar ratios of cationic/anionic monomers. The ionic conductivities of PADA gels prepared in solvent mixtures of propylene carbonate, ethyl methyl ether and dioxolane (3:1:1, v/v) were higher than those of PADA gels prepared in propylene carbonate only. Significantly, the ionic conductivities of two kinds of PADA gel electrolytes were in the range of 10 -3 and 10 -4 S cm -1 even at -30 deg. C. The electrochemical windows of PADA gel electrolytes measured by cyclic voltammetry were in the range from -1 V to 4.5 V

  4. Platelet-rich fibrin-mediated revitalization of immature necrotic tooth

    Directory of Open Access Journals (Sweden)

    Navin Mishra

    2013-01-01

    Full Text Available Contemporary studies have shown that the regeneration of tissues and root elongation is possible in necrotic immature permanent teeth. The purpose of this case report is to add a new vista in regenerative endodontic therapy by using platelet rich fibrin for revitalization of immature non vital tooth. An 11year old boy with the history of trauma was diagnosed with the pulpal necrosis and symptomatic apical periodontitis in tooth #21. Intra oral periapical radiograph showed open apex and associated immature supernumerary tooth with respect to tooth #21. Access preparation and minimal instrumentation was done to remove necrotic debris under copious irrigation with 2.5% sodium hypochlorite. Triple antibiotic paste was packed in the canal for four weeks. During second visit, 5 mL of whole blood was drawn from the medial cubital vein of the patient and blood was then subjected to centrifugation at 2400 rpm for 12 minutes for the preparation of Platelet rich fibrin (PRF utilizing Choukroun′s method. Triple antibiotic paste was removed and canal was dried. PRF clot was pushed to the apical region of tooth #21 using hand pluggers. Three milimetres of Mineral trioxide (MTA was placed in cervical part of the root canal and permanent restoration was done three days later. Clinical examination at 6 and 12 months revealed no sensitivity to percussion and palpation in tooth #21and it responded positively to both electric pulp and cold tests. Radiographic examination showed resolution of periapical rarefaction, further root development and apical closure of the tooth #21 and its associated supernumerary tooth. On the basis of successful outcome of the present case it can be stated that PRF clot may serve as a scaffold for regeneration of necrotic immature teeth.

  5. Crystallization of Na2O-SiO2 gel and glass

    Science.gov (United States)

    Neilson, G. F.; Weinberg, M. C.

    1984-01-01

    The crystallization behavior of a 19 wt pct soda silica gel and gel-derived glass was compared to that of the ordinary glass of the same composition. Both bulk and ground glass samples were utilized. X-ray diffraction measurements were made to identify the crystalline phases and gauge the extent of crystallization. It was found that the gel crystallized in a distinctive manner, while the gel glass behavior was not qualitatively different from that of the ordinary glass.

  6. Use of photoactivated disinfection and platelet-rich fibrin in regenerative Endodontics

    Science.gov (United States)

    Johns, Dexton Antony; Shivashankar, Vasundara Yayathi; Krishnamma, Shoba; Johns, Manu

    2014-01-01

    Aim: Photoactivated disinfection has been used as an adjunct to conventional endodontic treatment. Its use in regenerative endodontics is not reported in literature. The aim of this case report was to describe a new proposal for pulp revascularization with disinfection of pulp canal space using a unique combination of a photosensitizer solution and low-power laser light. Materials and Methods: A 9-year-old boy came with the chief complaint of discolored upper central incisors (#8, #9). A diagnosis of pulp necrosis was made on the basis of clinical and radiographic findings. The canal was irrigated with 5.25% sodium hypochlorite solution and dried with paper points. Photodynamic therapy was used to disinfect the root canal and platelet-rich fibrin was used to revitalize the pulp. Three millimeters of gray mineral trioxide aggregate was placed directly over the platelet-rich plasma clot. Three days later, the tooth was double-sealed with permanent filling materials. Results: Clinical examination revealed no sensitivity to percussion or palpation tests. Radiograph revealed continued thickening of the dentinal walls, root lengthening, regression of the peri-apical lesion and apical closure. Both the roots showed complete apical closure at the 10-month follow-up. However, the teeth were not responsive to electric pulp test. Conclusion: This report of pulp revascularization shows that disinfection with photodynamic therapy combined with platelet-rich fibrin leads to satisfactory root development in necrotic immature teeth. PMID:25298655

  7. Thorium inorganic gels

    International Nuclear Information System (INIS)

    Genet, M.; Brandel, V.

    1988-01-01

    The optimum pH and concentration values of thorium salts and oxoacids or oxoacid salts which lead to transparent and stable inorganic gels have been determined. The isotherm drying process of the gel at 50 0 C leads successively to a partly dehydrated gel, then, to the formation of an unusual liquid phase and, finally to a dry amorphous solid phase which is still transparent. This kind of transparent inorganic gels and amorphous phase can be used as matrices for spectroscopic studies [fr

  8. Monte Carlo verification of polymer gel dosimetry applied to radionuclide therapy: a phantom study

    International Nuclear Information System (INIS)

    Gear, J I; Partridge, M; Flux, G D; Charles-Edwards, E

    2011-01-01

    This study evaluates the dosimetric performance of the polymer gel dosimeter 'Methacrylic and Ascorbic acid in Gelatin, initiated by Copper' and its suitability for quality assurance and analysis of I-131-targeted radionuclide therapy dosimetry. Four batches of gel were manufactured in-house and sets of calibration vials and phantoms were created containing different concentrations of I-131-doped gel. Multiple dose measurements were made up to 700 h post preparation and compared to equivalent Monte Carlo simulations. In addition to uniformly filled phantoms the cross-dose distribution from a hot insert to a surrounding phantom was measured. In this example comparisons were made with both Monte Carlo and a clinical scintigraphic dosimetry method. Dose-response curves generated from the calibration data followed a sigmoid function. The gels appeared to be stable over many weeks of internal irradiation with a delay in gel response observed at 29 h post preparation. This was attributed to chemical inhibitors and slow reaction rates of long-chain radical species. For this reason, phantom measurements were only made after 190 h of irradiation. For uniformly filled phantoms of I-131 the accuracy of dose measurements agreed to within 10% when compared to Monte Carlo simulations. A radial cross-dose distribution measured using the gel dosimeter compared well to that calculated with Monte Carlo. Small inhomogeneities were observed in the dosimeter attributed to non-uniform mixing of monomer during preparation. However, they were not detrimental to this study where the quantitative accuracy and spatial resolution of polymer gel dosimetry were far superior to that calculated using scintigraphy. The difference between Monte Carlo and gel measurements was of the order of a few cGy, whilst with the scintigraphic method differences of up to 8 Gy were observed. A manipulation technique is also presented which allows 3D scintigraphic dosimetry measurements to be compared to polymer

  9. Proton spectroscopic imaging of polyacrylamide gel dosimeters for absolute radiation dosimetry

    International Nuclear Information System (INIS)

    Murphy, P.S.; Schwarz, A.J.; Leach, M.O.

    2000-01-01

    Proton spectroscopy has been evaluated as a method for quantifying radiation induced changes in polyacrylamide gel dosimeters. A calibration was first performed using BANG-type gel samples receiving uniform doses of 6 MV photons from 0 to 9 Gy in 1 Gy intervals. The peak integral of the acrylic protons belonging to acrylamide and methylenebisacrylamide normalized to the water signal was plotted against absorbed dose. Response was approximately linear within the range 0-7 Gy. A large gel phantom irradiated with three, coplanar 3x3cm square fields to 5.74 Gy at isocentre was then imaged with an echo-filter technique to map the distribution of monomers directly. The image, normalized to the water signal, was converted into an absolute dose map. At the isocentre the measured dose was 5.69 Gy (SD = 0.09) which was in good agreement with the planned dose. The measured dose distribution elsewhere in the sample shows greater errors. A T 2 derived dose map demonstrated a better relative distribution but gave an overestimate of the dose at isocentre of 18%. The data indicate that MR measurements of monomer concentration can complement T 2 -based measurements and can be used to verify absolute dose. Compared with the more usual T 2 measurements for assessing gel polymerization, monomer concentration analysis is less sensitive to parameters such as gel pH and temperature, which can cause ambiguous relaxation time measurements and erroneous absolute dose calculations. (author)

  10. DNA double-strand breaks measured by pulsed-field gel electrophoresis in irradiated lymphocytes from normal humans and those with Alzheimer's disease

    International Nuclear Information System (INIS)

    Tobi, S.E.; Itzhaki, R.F.

    1993-01-01

    The authors previously found that radiation-induced chromosome aberrations (dicentrics) are more numerous in lymphocytes from Alzheimer's disease (AD) patients than in those from age-matched normal individuals (Tobi et al. 1990). They have examined double-strand breaks (dsb) produced by g amma - irradiation in the DNA of AD and normal lymphocytes by using pulsed-field gel electrophoresis. The percentage of DNA migrating into the gels is an indirect measure of the number of dsb; DNA content of sequential slices of the gel was assayed by direct fluorometry and the percentage migrating was dose dependent. Results show that the level of damage is similar in AD and normal lymphocytes and preliminary assays of the rate of repair suggest that the half-time is also similar, the value being > 1 h. The latter is consistent with the known rate of rejoining of chromosome fragments in interphase lymphocytes (Pantelias and Maillie 1985). (Author)

  11. Differences in body composition measured using the bioelectrical impedance analysis with steel and gel electrodes – on an example of professional fencers

    Directory of Open Access Journals (Sweden)

    Olga Mizera

    2018-03-01

    Full Text Available Introduction: Regular assessment of body composition in athletes is a key element of their nutritional status and general condition monitoring. Purpose: Analysis of differences in the impedance (I and body composition measurements performed by the use of analyzers with a constant current frequency of 50 kHz with steel and gel electrodes. Material and methods: Analysis were performed in experienced fencers by the use of analyzers: Tanita BC418MA (aT with steel electrodes (eT and Akern BIA101ASE (aA with gel electrodes (eA, eL, eT. During the first stage of the study in 48 athletes I, fat mass (FM and fat free mass (FFM were measured using aA with eB in a supine position and after 3 min using aT with eT in a standing position. Then 10 fencers were randomly selected. For them measurements were performed after 10, 13 and 16 min in a supine position using eA, eL, eB and then after 3 min in a standing one using eT. Intrinsic impedance of the 3 types of gel electrodes (eA, eL, eB were measured using aA. Results: The first stage. Differences in I, FM and FFM between eT and aA were observed (women: 101.4±52.2Ω, 1.2±2.1kg, -1.2±2.1kg, men: 98.8±27.5Ω, 1.1±1.5kg, -1.1±1.5kg, respectively. The second stage. In the subsequent measurements, differences in I were observed (women: eL-eA 3.8±1.8Ω, eB-eA 26.1±8.0Ω, eT-eA 154.4±40.6Ω;, men: of -0.7±9.4Ω, 11.1±9.2Ω, 107±36.3Ω, respectively. In both subgroups along with the increase in I, FM also increased, while  FFM decreased. Intrinsic impedance of the applied gel electrodes was measured and the differences between the results were reported (eL-eA 41.1±22.0Ω, eB-eL 138.4±20.7Ω, eB-eA 179.5Ω. As the intrinsic impedance of gel electrodes increased, an increase in the whole body I was observed. Conclusion: It seems that the observed differences in the whole body impedance were not only a simple effect of changes in a body position but they might have also been related to the intrinsic

  12. HIF-2α Expression Regulates Sprout Formation into 3D Fibrin Matrices in Prolonged Hypoxia in Human Microvascular Endothelial Cells.

    Science.gov (United States)

    Nauta, Tessa D; Duyndam, Monique C A; Weijers, Ester M; van Hinsbergh, Victor M W; Koolwijk, Pieter

    2016-01-01

    During short-term hypoxia, Hypoxia Inducible Factors (particular their subunits HIF-1α and HIF-2α) regulate the expression of many genes including the potent angiogenesis stimulator VEGF. However, in some pathological conditions chronic hypoxia occurs and is accompanied by reduced angiogenesis. We investigated the effect of prolonged hypoxia on the proliferation and sprouting ability of human microvascular endothelial cells and the involvement of the HIFs and Dll4/Notch signaling. Human microvascular endothelial cells (hMVECs), cultured at 20% oxygen for 14 days and seeded on top of 3D fibrin matrices, formed sprouts when stimulated with VEGF-A/TNFα. In contrast, hMVECs precultured at 1% oxygen for 14 days were viable and proliferative, but did not form sprouts into fibrin upon VEGF-A/TNFα stimulation at 1% oxygen. Silencing of HIF-2α with si-RNA partially restored the inhibition of endothelial sprouting, whereas HIF-1α or HIF-3α by si-RNA had no effect. No involvement of Dll4/Notch pathway in the inhibitory effect on endothelial sprouting by prolonged hypoxia was found. In addition, hypoxia decreased the production of urokinase-type plasminogen activator (uPA), needed for migration and invasion, without a significant effect on its inhibitor PAI-1. This was independent of HIF-2α, as si-HIF-2α did not counteract uPA reduction. Prolonged culturing of hMVECs at 1% oxygen inhibited endothelial sprouting into fibrin. Two independent mechanisms contribute. Silencing of HIF-2α with si-RNA partially restored the inhibition of endothelial sprouting pointing to a HIF-2α-dependent mechanism. In addition, reduction of uPA contributed to reduced endothelial tube formation in a fibrin matrix during prolonged hypoxia.

  13. Platelet-rich fibrin: a boon in regenerative endodontics.

    Science.gov (United States)

    Rebentish, Priyanka D; Umashetty, Girish; Kaur, Harpreet; Doizode, Trupthi; Kaslekar, Mithun; Chowdhury, Shouvik

    2016-12-01

    Research into regenerative dentistry has contributed momentum to the field of molecular biology. Periapical surgery aims at removing periapical pathology to achieve complete wound healing and regeneration of bone and periodontal tissue. Regenerative endodontic procedures are widely being added to the current armamentarium of pulp therapy procedures. The regenerative potential of platelets has been deliberated. Platelet-rich fibrin (PRF) is a wonderful tissue-engineering product and has recently gained much popularity due its promising results in wound healing bone induction. The features of this product are an attribute of platelets which, after cellular interactions, release growth factors and have shown application in diverse disciplines of dentistry. This paper is intended to shed light onto the various prospects of PRF and to provide clinical insight into regenerative endodontic therapy.

  14. Platelet-rich-fibrin: A novel root coverage approach

    Directory of Open Access Journals (Sweden)

    Anilkumar K

    2009-01-01

    Full Text Available Treatment of gingival recession has become an important therapeutic issue due to increasing cosmetic demand. Multiple surgical procedures have been developed to obtain predictable esthetic root coverage. More specifically, after periodontal regenerative surgery, the aim is to achieve complete wound healing and regeneration of the periodontal unit. A recent innovation in dentistry is the preparation and use of platelet-rich plasma (PRP, a concentrated suspension of the growth factors, found in platelets. These growth factors are involved in wound healing and postulated as promoters of tissue regeneration. This paper reports the use of PRF membrane for root coverage on the labial surfaces of the mandibular anterior teeth. This was accomplished using laterally displaced flap technique with platelet rich fibrin (PRF membrane at the recipient site.

  15. A Practical Use for FXG Gel Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Olding, T; Salomons, G; Darko, J; Schreiner, L J, E-mail: Tim.Olding@krcc.on.c

    2010-11-01

    In-phantom Fricke-xylenol orange-gelatin (FXG) gel dosimetry yields three dimensional (3D) dose data for intensity modulated radiation therapy (IMRT) treatment plan verification within 18-24 hours from the point of request. The information obtained from a 3% dose difference, 3 mm distance-to-agreement gamma function comparison between treatment plan dose and gel-measured dose then provides a useful secondary 3D quality assurance check of the treatment plan prior to delivery.

  16. Simple measurement of 14C in the environment using a gel suspension method

    International Nuclear Information System (INIS)

    Wakabayashi, G.; Ohura, H.; Okai, T.; Matoba, M.

    1999-01-01

    A simple analytical method for environmental 14 C with a low background liquid scintillation counter was developed. A new gelling agent, N-lauroyl-L-glutamic-α,γ-dibutylamide was used, for the liquid scintillation counting of 14 C as CaCO 3 (gel suspension method). Our procedure for sample preparation was much simpler than that of conventional methods and required no special equipment. The samples prepared with the standard sample of CaCO 3 were measured to evaluate the self absorption of the sample, the optimum condition of counting and the detection limit. Our results indicated that the newly developed technique could be efficiently applied for the monitoring of environmental 14 C. (author)

  17. A nonadhesive solid-gel electrode for a non-invasive brain–machine interface

    Directory of Open Access Journals (Sweden)

    Shigeru eToyama

    2012-07-01

    Full Text Available A non-invasive brain–machine interface (BMI or brain-computer interface (BCI is a technology for helping individuals with disabilities and utilizes neurophysiological signals from the brain to control external machines or computers without requiring surgery. However, when applying EEG methodology, users must place EEG electrodes on the scalp each time, and the development of easy-to-use electrodes for clinical use is required. In this study, we developed a conductive nonadhesive solid-gel electrode for practical non-invasive BMIs. We performed basic material testing, including examining the volume resistivity, viscoelasticity, and moisture-retention properties of the solid gel. Then, we compared the performance of the solid gel, a conventional paste, and an in-house metal pin-based electrode using impedance measurements and P300-BMI testing. The solid gel was observed to be conductive (volume resistivity 13.2 Ωcm and soft (complex modulus 105.4 kPa, and it remained wet for a prolonged period (>10 hours in a dry environment. Impedance measurements revealed that the impedance of the solid-gel-based and conventional paste-based electrodes was superior to that of the pin-based electrode. The EEG measurement suggested that the signals obtained with the solid-gel electrode were comparable to those with the conventional paste-based electrode. Moreover, the P300-BMI study suggested that systems using the solid-gel or pin-based electrodes were effective. One of the advantages of the solid gel is that it does not require cleaning after use, whereas the conventional paste adheres to the hair, which requires washing. Furthermore, the solid-gel electrode was not painful compared with a metal-pin electrode. Taken together, the results suggest that the solid-gel electrode worked well for practical BMIs and could be useful for bedridden patients such as those with amyotrophic lateral sclerosis.

  18. A collagen-fibrin patch for the prevention of symptomatic lymphoceles after pelvic lymphadenectomy in women with gynecologic malignancies: A randomized clinical trial.

    Science.gov (United States)

    Grimm, Christoph; Polterauer, Stephan; Helmy-Bader, Samir; Zikan, Michal; Cibula, David; Heitz, Florian; Harter, Philipp; Giese, Arnd; Reinthaller, Alexander; Tempfer, Clemens

    2018-04-01

    To evaluate the efficacy of a collagen-fibrin patch for the prevention of symptomatic lymphoceles after pelvic lymphadenectomy in women with gynecologic malignancies. In a multicenter, randomized, clinical trial, 164 women with pelvic lymphadenectomy were allocated either to bilateral pelvic application of two collagen-fibrin patches or no intervention. Main outcome was efficacy, defined as reduction of symptomatic lymphocele rate diagnosed within four weeks after surgery. Secondary outcomes were asymptomatic lymphoceles and subsequent interventions. Sample size was based on the assumption that application of a collagen-fibrin patch reduces the prevalence of symptomatic lymphoceles by at least 66%. The study was single-blinded, i.e., patients and primary outcome assessors, but not surgeons, were blinded to the treatment allocation. A total of 75 women were randomized to the intervention and 89 to the control group. All women received the allocated intervention. In total, 42 (27.4%) lymphoceles and 8 (5.2%) symptomatic lymphoceles were observed. Symptomatic lymphoceles were observed in 5/68 (7.4%) women in the intervention group and 3/85 (3.5%) women in the control group (p = 0.47). Asymptomatic lymphoceles were observed in 16 (23.5%) women in the intervention group compared to 18 (21.2%) in the control group (p = 0.85). In a multivariate logistic regression model, no independent risk factor for the development of a symptomatic lymphocele was ascertained. Intraoperative application of collagen-fibrin patches to the pelvic side walls does not reduce the incidence of symptomatic lymphoceles in women with gynecologic malignancies undergoing pelvic lymphadenectomy. Copyright © 2018. Published by Elsevier Inc.

  19. Management of multiple recession defects in esthetic zone using platelet-rich fibrin membrane: A 36-month follow-up case report.

    Science.gov (United States)

    Singh, Prabhjeet; Shukla, Sagrika; Singh, Kuldeep

    2018-01-01

    A patient undergoing orthodontic treatment presented with multiple recession defects in maxillary anterior region. After thorough clinical examination and assessment, measurements were recorded. Maxillary anterior teeth with recession defects of 3-4 mm were treated with coronally advanced flap and platelet-rich fibrin (PRF) membrane. Regular follow-up was maintained for the patient at 3, 6 , 12, 18, 24, 30, and 36 months. After 36 months, significant root coverage of 100 percent was observed in four defects and 50% coverage in one defect. This shows that PRF membrane along with coronally advanced provides a predictable and significant result for management of recession defects.

  20. Platelet rich fibrin in jaw defects

    Science.gov (United States)

    Nica, Diana; Ianes, Emilia; Pricop, Marius

    2016-03-01

    Platelet rich fibrin (PRF) is a tissue product of autologous origin abundant in growth factors, widely used in regenerative procedures. Aim of the study: Evaluation of the regenerative effect of PRF added in the bony defects (after tooth removal or after cystectomy) Material and methods: The comparative nonrandomized study included 22 patients divided into 2 groups. The first group (the test group) included 10 patients where the bony defects were treated without any harvesting material. The second group included 12 patients where the bony defects were filled with PRF. The bony defect design was not critical, with one to two walls missing. After the surgeries, a close clinically monitoring was carried out. The selected cases were investigated using both cone beam computer tomography (CBCT) and radiographic techniques after 10 weeks postoperatively. Results: Faster bone regeneration was observed in the bony defects filled with PRF comparing with the not grafted bony defects. Conclusions: PRF added in the bony defects accelerates the bone regeneration. This simplifies the surgical procedures and decreases the economic costs.

  1. Neutrophil Extracellular Traps and Fibrin in Otitis Media: Analysis of Human and Chinchilla Temporal Bones.

    Science.gov (United States)

    Schachern, Patricia A; Kwon, Geeyoun; Briles, David E; Ferrieri, Patricia; Juhn, Steven; Cureoglu, Sebahattin; Paparella, Michael M; Tsuprun, Vladimir

    2017-10-01

    Bacterial resistance in acute otitis can result in bacterial persistence and biofilm formation, triggering chronic and recurrent infections. To investigate the middle ear inflammatory response to bacterial infection in human and chinchilla temporal bones. Six chinchillas underwent intrabullar inoculations with 0.5 mL of 106 colony-forming units (CFUs) of Streptococcus pneumoniae, serotype 2. Two days later, we counted bacteria in middle ear effusions postmortem. One ear from each chinchilla was processed in paraffin and sectioned at 5 µm. The opposite ear was embedded in epoxy resin, sectioned at a thickness of 1 µm, and stained with toluidine blue. In addition, we examined human temporal bones from 2 deceased donors with clinical histories of otitis media (1 with acute onset otitis media, 1 with recurrent infection). Temporal bones had been previously removed at autopsy, processed, embedded in celloidin, and cut at a thickness of 20 µm. Sections of temporal bones from both chinchillas and humans were stained with hematoxylin-eosin and immunolabeled with antifibrin and antihistone H4 antibodies. Histopatological and imminohistochemical changes owing to otitis media. Bacterial counts in chinchilla middle ear effusions 2 days after inoculation were approximately 2 logs above initial inoculum counts. Both human and chinchilla middle ear effusions contained bacteria embedded in a fibrous matrix. Some fibers in the matrix showed positive staining with antifibrin antibody, others with antihistone H4 antibody. In acute and recurrent otitis media, fibrin and neutrophil extracellular traps (NETs) are part of the host inflammatory response to bacterial infection. In the early stages of otitis media the host defense system uses fibrin to entrap bacteria, and NETs function to eliminate bacteria. In chronic otitis media, fibrin and NETs appear to persist.

  2. Unfolding of hemoglobin variants--insights from urea gradient gel electrophoresis photon correlation spectroscopy and zeta potential measurements

    International Nuclear Information System (INIS)

    Bhattacharya, Jaydeep; GhoshMoulick, Ranjita; Choudhuri, Utpal; Chakrabarty, Prantar; Bhattacharya, Pranab K.; Lahiri, Prabir; Chakraborti, Bikas; Dasgupta, Anjan Kr.

    2004-01-01

    The unfolding pattern of crystal human hemoglobin and variants of hemoglobin obtained from hemolysate were studied using transverse urea gradient gel electrophoresis (TUGGE). A smooth sigmoid like increase of electrophoretic mobility was observed with increasing urea concentrations. A decrease in electrophoretic mobility resulted, if the protein was unfolded with guanidium hydrochloride (GdnHCl). The anomaly was resolved after the Stoke's radii (obtained using the photon correlation spectroscopy) and zeta potential (measured using laser Doppler velocimetry) measurements were made at different denaturant concentrations. Addition of denaturant led to formation of extended structure, irrespective of the nature of the denaturant, as indicated by increase in Stoke's radii in both cases (urea and GdnHCl). The unexpected increase in electrophoretic mobility in case of urea could be explained in terms of a critical redistribution of negative charge at intermediate stages of the unfolding process. In case of GdnHCl, the higher ionic strength masked the charge effect. The mobility, being solely dependent on size, decreased at higher denaturant concentration. Incidentally, folding loci of other hemoglobin variants (e.g. HbE) or that of post-translationally modified hemoglobin (e.g. HbA1c) could be determined by studying the charge distribution and hydrodynamic radius at varying denaturing stress and in each case the gel migration profile could be approximately scaled by the ratio of charge and hydrodynamic diameter of the protein. While unfolding induced charge effect was most pronounced in HbA0 (and crystal ferrous hemoglobin), the unfolding induced aggregation (manifested by the increase in Stoke's radii) was predominantly observed in the variant forms HbE and HbA1c. Representing the proteins by a plot, in which charge and hydrodynamic diameter are on independent axes, may be a useful way of characterizing protein variants having similar migration profiles on native gels

  3. Investigation of the dose rate dependency of the PAGAT gel dosimeter at low dose rates

    International Nuclear Information System (INIS)

    Zehtabian, M.; Faghihi, R.; Zahmatkesh, M.H.; Meigooni, A.S.; Mosleh-Shirazi, M.A.; Mehdizadeh, S.; Sina, S.; Bagheri, S.

    2012-01-01

    Medical physicists need dosimeters such as gel dosimeters capable of determining three-dimensional dose distributions with high spatial resolution. To date, in combination with magnetic resonance imaging (MRI), polyacrylamide gel (PAG) polymers are the most promising gel dosimetry systems. The purpose of this work was to investigate the dose rate dependency of the PAGAT gel dosimeter at low dose rates. The gel dosimeter was used for measurement of the dose distribution around a Cs-137 source from a brachytherapy LDR source to have a range of dose rates from 0.97 Gy h −1 to 0.06 Gy h −1 . After irradiation of the PAGAT gel, it was observed that the dose measured by gel dosimetry was almost the same at different distances (different dose rates) from the source, although the points nearer the source had been expected to receive greater doses. Therefore, it was suspected that the PAGAT gel is dose rate dependent at low dose rates. To test this further, three other sets of measurements were performed by placing vials containing gel at different distances from a Cs-137 source. In the first two measurements, several plastic vials were exposed to equal doses at different dose rates. An ionization chamber was used to measure the dose rate at each distance. In addition, three TLD chips were simultaneously irradiated in order to verify the dose to each vial. In the third measurement, to test the oxygen diffusion through plastic vials, the experiment was repeated again using plastic vials in a nitrogen box and glass vials. The study indicates that oxygen diffusion through plastic vials for dose rates lower than 2 Gy h −1 would affect the gel dosimeter response and it is suggested that the plastic vials or (phantoms) in an oxygen free environment or glass vials should be used for the dosimetry of low dose rate sources using PAGAT gel to avoid oxygen diffusion through the vials.

  4. Colloid molecular weight estimation by gel chromatography/acrylamide gel electrophoresis

    International Nuclear Information System (INIS)

    Liberatore, F.A.; Dearborn, C.; Nigam, S.; Poon, C.; Camin, L.; Liteplo, M.

    1984-01-01

    Size or molecular weight (MW) estimation of radiolabeled collides in aqueous solutions has long been a problem. The authors have prepared several minimicroaggregated albumin colloids (mμAA) by heat denaturation of stannous-containing HSA solutions at pH 7.0, 7.5, and 8.5). The resulting colloids were labeled with Tc-99m and compared with Au-198 colloid and Tc-99m-antimony sulfide colloid (Tc-99m-Sb/sub 2/S3) by gel chromatography and gel electrophoresis. Tc-99mm-mμAA aggregated at pH 7.0 and the Au-198 colloid appeared in the external void volume of a BioRad A5.0 agarose column indicating an apparent MW of > 5 x 10/sup 6/ daltons. The pH7.5 Tc-99m-mμAA, migrated within the filtration range of the column as did a small fraction of Tc-99m-Sb/sub 2/S/sub 3/, suggesting that the MW is between 6 x 10/sup 4/ - 5 x 10/sup 6/ daltons. The Tc-99m-mμAA, aggregated at pH 8.5, had an apparent MW on gel filtration similar to that of untreated albumin, MW 6.6 x 10-/sup 4/ daltons. The mobilities of the colloids, on acrylamide disc gel electrophoresis, were consistent with the results on gel chromatography. The largest colloids, Au-198 colloid and pH 7.0 Tc-99m-mμAA, barely entered the separating gel; intermediate sized colloids, a small fraction of Tc-99m-Sb/sub 2/S/sub 3/ and pH 7.5 Tc-99m-mμAA migrated farther into the separating gel; while pH 8.5 Tc-99m-mμAA had mobility approaching that of untreated albumin. Lymphoscintigraphy studies using these colloids in animals showed the predicted, particle size-related differences in migration and clearance. The authors conclude that gel chromatography and gel electrophoresis are useful methods for estimating the apparent size of the colloidal particles

  5. Three dimensional measurement of dose distributions produced by a robot-mounted linac using magnetic resonance imaging of bang polymer gel dosimeters

    International Nuclear Information System (INIS)

    Wong, S.P.; Garwood, D.P.; Clarke, G.D.; McColl, R.W.; Maryanski, M.J.; Gore, J.C.

    1996-01-01

    Purpose/Objective: A novel image-guided robotic radiosurgical system, capable of irradiating 102 non-coplanar nodes in 3 π geometry, produces complex dose distributions which are difficult or impractical to measure with conventional dosimetry instrumentation. The recently developed BANG polymer gel dosimetry system provides accurate, high resolution and three dimensional dose distributions data and is ideally suited for the task described above. In this study, the polymer gels were used for imaging the dose distributions produced by this extremely flexible radiosurgical system. Materials and Methods: The dosimeter materials consist of 2-liter BANG polymer gels in spherical, clear glass flasks, closed with ground glass stoppers, with glass rods extending to the center of the gel that serve as a target for the frameless robotic radiosurgery. A compact 6 MV x-band linac (285 lbs) is mounted and maneuvered by a 6 degree-of-freedom robotic arm. The gels were irradiated using a 25 mm circular insert. A total of 10 Gy was delivered at isocenter at a dose rate of 300 cGy/min using all of the available 102 nodes. The gels were then imaged by MRI(GE Signa) at 1.5 T, using a series of Hahn spin echoes of TR = 3s, TE = 20,100,200,400 ms. Transverse relaxation rate (R 2 ) maps were constructed from those multiple images, using the non-linear least-squares Lavenberg-Marquardt algorithm and a data analysis and display program 'DoseMap' which was written using the scientific computational program MATLAB. R 2 maps were converted to dose maps using an R 2 -to-dose calibration curve. Dose maps and isodose curves were then compared with corresponding data from the treatment planning computer software. Results: The dose dependence of the NMR transverse relaxation rate, R 2 , is reproducible (less than 2 % variation) and is linear up to about 10 Gy, with a slope of 0.25 s -1 Gy -1 at 1.5 Tesla. Isodose curves in three orthogonal (axial, sagittal and coronal) planes show excellent

  6. Growth factor and proteinase profile of Vivostat® platelet-rich fibrin linked to tissue repair

    DEFF Research Database (Denmark)

    Ågren, Sven Per Magnus; Rasmussen, Karina; Pakkenberg, Bente

    2014-01-01

    . Leucocyte, erythrocyte and platelet counts in whole blood and fibrin-I were determined by automated haematology analyser. Platelet concentration in PRF was quantified manually by stereologic analysis of Giemsa-stained tissue sections, and the total content of five growth factors and MMP-9 by enzyme......·001]. MMP-9 was reduced 139-fold (P tissue regenerative applications....

  7. Sustained subconjunctival protein delivery using a thermosetting gel delivery system.

    Science.gov (United States)

    Rieke, Erin R; Amaral, Juan; Becerra, S Patricia; Lutz, Robert J

    2010-02-01

    An effective treatment modality for posterior eye diseases would provide prolonged delivery of therapeutic agents, including macromolecules, to eye tissues using a safe and minimally invasive method. The goal of this study was to assess the ability of a thermosetting gel to deliver a fluorescently labeled protein, Alexa 647 ovalbumin, to the choroid and retina of rats following a single subconjunctival injection of the gel. Additional experiments were performed to compare in vitro to in vivo ovalbumin release rates from the gel. The ovalbumin content of the eye tissues was monitored by spectrophotometric assays of tissue extracts of Alexa 647 ovalbumin from dissected sclera, choroid, and retina at time points ranging from 2 h to 14 days. At the same time points, fluorescence microscopy images of tissue samples were also obtained. Measurement of intact ovalbumin was verified by LDS-PAGE analysis of the tissue extract solutions. In vitro release of Alexa 488 ovalbumin into 37 degrees C PBS solutions from ovalbumin-loaded gel pellets was also monitored over time by spectrophotometric assay. In vivo ovalbumin release rates were determined by measurement of residual ovalbumin extracted from gel pellets removed from rat eyes at various time intervals. Our results indicate that ovalbumin concentrations can be maintained at measurable levels in the sclera, choroid, and retina of rats for up to 14 days using the thermosetting gel delivery system. The concentration of ovalbumin exhibited a gradient that decreased from sclera to choroid and to retina. The in vitro release rate profiles were similar to the in vivo release profiles. Our findings suggest that the thermosetting gel system may be a feasible method for safe and convenient sustained delivery of proteins to choroidal and retinal tissue in the posterior segments of the eye.

  8. Development and dosimetric evaluation of radiochromic PCDA vesicle gel dosimeters

    International Nuclear Information System (INIS)

    Sun, P.; Fu, Y.C.; Hu, J.; Hao, N.; Huang, W.; Jiang, B.

    2016-01-01

    The gel dosimeter has the unique capacity in recording radiation dose distribution in three dimensions (3D), which has the specific advantages in dosimetry measurements where steep dose gradients exist, such as in intensity-modulated radiation therapy (IMRT), brachytherapy and so on. Some 3D dosimeters, such as Fricke gel dosimeters, polymer gel dosimeters, the PRESAGE plastic dosimeters and micelle gel dosimeters have appeared recently. However, there are several disadvantages of these 3D dosimeters limit their application in radiotherapy dose verification. In this study, a novel radiochromic gel dosimeter for 3D dose verification of radiotherapy was developed by dispersing nanovesicles self-assembled by 10,12-pentacosadiynoic acid (PCDA) into the tissue equivalence gel matrix. The characteristics of radiochromic PCDA vesicle gel dosimeters were evaluated. The results indicate that these radiochromic gel dosimeters have good linear dose response to X-ray irradiation in the dose range of 2–100 Gy. In addition, the radiochromic gel dosimeters breakthrough the limitations of the existing gel dosimeters such as diffusion effect, post-radiation effect, and poor forming ability. The response of the gel dosimeter does not show any dose rate dependence, energy dependence and temperature effect, and there was no obvious difference in the gel response between single and cumulative dose of fractional irradiation. Hence, the radiochromic PCDA vesicle gel dosimeters developed in this study could be generally applied to 3D dose verification in radiotherapy. - Highlights: • A novel radiochromic gel dosimeter was developed by dispersing PCDA nanovesicles into the tissue equivalence gel matrix. • This nanovesicle overcomes the dose image blurring caused by the diffusion of monomer molecules. • This nanovesicle limits the polymer chain growth, so as to reduce the post-radiation effect. • The gel matrixes possess excellent tissue equivalence and elastic strength, which

  9. The potential applications of fibrin-coated electrospun polylactide nanofibers in skin tissue engineering

    Czech Academy of Sciences Publication Activity Database

    Bačáková, Markéta; Musílková, Jana; Riedel, Tomáš; Stránská, D.; Brynda, Eduard; Žaloudková, Margit; Bačáková, Lucie

    2016-01-01

    Roč. 11, č. 2016 (2016), s. 771-789 E-ISSN 1178-2013 R&D Projects: GA ČR(CZ) GBP108/12/G108; GA MŠk(CZ) ED1.1.00/02.0109 Institutional support: RVO:67985823 ; RVO:61389013 ; RVO:67985891 Keywords : electrospun nanofibers * nanocoating * skin tissue engineering * fibroblasts * fibrin Subject RIV: EI - Biotechnology ; Bionics; CD - Macromolecular Chemistry (UMCH-V); JI - Composite Materials (USMH-B) Impact factor: 4.300, year: 2016

  10. Knee temperatures measured in vivo after arthroscopic ACL reconstruction followed by cryotherapy with gel-packs or computer controlled heat extraction.

    Science.gov (United States)

    Rashkovska, Aleksandra; Trobec, Roman; Avbelj, Viktor; Veselko, Matjaž

    2014-09-01

    To obtain in vivo data about intra- and extra-articular knee temperatures to assess the effectiveness of two cryotherapeutic methods-conventional cooling with gel-packs and computer controlled cryotherapy following anterior cruciate ligament (ACL) reconstructive surgery. Twenty patients were arbitrarily assigned for cryotherapy after ACL reconstruction: 8 patients with frozen gel-packs and 12 patients with computer controlled cryotherapy with constant temperatures of the cooling liquid in the knee pads. The treatment was performed for 12 h. Temperatures were measured with two thermo sensors in catheters placed intraarticularly and subcutaneously, four sensors on the skin and one sensor under protective bandage, every second for 16 h after surgery. In the first 2 h of treatment, there were no significant differences (n.s.) between the groups in temperatures in the intracondylar notch. After 4 h of cryotherapy, the temperatures were significantly lower on the skin (24.6 ± 2.8 and 31.4 ± 1.3 °C, p cryotherapy group compared to the gel-pack group. The cooling effect of the arthroscopy irrigation fluid on the knee temperature is evident in the first 2 h of treatment. The energy extraction is significantly more effective and controllable by computer controlled cryotherapy than with frozen gel-packs. Prospective comparative study, Level II.

  11. Platelet-rich fibrin: Evolution of a second-generation platelet concentrate

    Directory of Open Access Journals (Sweden)

    Sunitha Raja V

    2008-01-01

    Full Text Available Platelet-rich plasma (PRP is a platelet concentrate that has been used widely to accelerate soft-tissue and hard-tissue healing. The preparation of PRP has been described by several authors. Platelet-rich fibrin (PRF was first described by Choukroun et al. in France. It has been referred to as a second-generation platelet concentrate, which has been shown to have several advantages over traditionally prepared PRP. Its chief advantages include ease of preparation and lack of biochemical handling of blood, which makes this preparation strictly autologous. This article describes the evolution of this novel platelet concentrate, referred to as PRF.

  12. Simple measurement of 14C in the environment using gel suspension method

    International Nuclear Information System (INIS)

    Wakabayashi, Genichiro; Oura, Hirotaka; Nagao, Kenjiro; Okai, Tomio; Matoba, Masaru; Kakiuchi, Hideki; Momoshima, Noriyuki; Kawamura, Hidehisa

    1999-01-01

    A gel suspension method using N-lauroyl-L-glutamic-α, γ-dibutylamide as gelling agent and calcium carbonate as sample was studied and it was proved a more simple measurement method of 14 C in environment than the ordinary method. 100, 20 and 7 ml of sample could introduce 3.6, 0.72 and 0.252 g of carbon, respectively. When 100 ml and 20 ml of vial introduced the maximum carbon, the lower limit of detection was about 0.3 dpm/g-C and 0.5 dpm/g-C, respectively. These values showed that this method was able to determine 14 C in the environment. The value of sample has been constant for two years or more. This fact indicated the sample prepared by this method was good for repeat measurement and long-term storage. Many samples prepared by the same calcium carbonate showed almost same values. The concentrations of 14 C in the growth rings of a tree and in rice in the environment were determined and the results agreed with the values in the references. From these above results, this method is more simple measurement method of 14 C in the environment than the ordinary method and can apply to determine 14 C in and around the nuclear installation. (S.Y.)

  13. Preliminary investigation of PAGAT polymer gel radionuclide dosimetry of Tc-99m

    Science.gov (United States)

    Braun, Kelly; Bailey, Dale; Hill, Brendan; Baldock, Clive

    2009-05-01

    PAGAT polymer gel was investigated as a suitable dosimeter materials for measuring absorbed dose from the unsealed source radionuclide Tc-99m. Differing amounts of Tc-99m over the range of 25-5000 MBq were introduced into a normoxic polymer gel mixture (PAGAT) in sealed nitrogen-filled P6 glass vials. After irradiation the gels were evaluated using MRI more than 48 hours after preparation to allow for radioactive decay. The dose delivered to the vial was also calculated empirically. R2 versus total activity curves were obtained over a number of experiments and these were used to evaluate the relationship between the amount of gel polymerization and the dose deposited by the radionuclide. A linear response up to 1000 MBq (corresponding to 20Gy) was displayed and was still behaving monotonically at 5000 MBq. Polymer gels offer the potential to measure radiation dose three-dimensionally using MRI.

  14. Light scattering from a binary-liquid entanglement gel

    Science.gov (United States)

    Xia, K.-Q.; Maher, J. V.

    1987-09-01

    Light-scattering experiments have been carried out on an entanglement gel with a binary-liquid mixture as solvent. The onset temperature for critical opalescence has a composition dependence which is similar to the coexistence curve of the free-liquid mixture. This system resembles previously reported work on the cross-linked gel polyacrylamide in two ways: (1) As temperature is lowered toward the critical temperature of the free-liquid mixture, the binary-fluid gel exhibits a strong and increasing light scattering over a broad temperature region of several kelvins, and (2) no appreciable temporal fluctuations are observed throughout this temperature region. Two added features are observed in the present, entanglement-gel measurements: (a) Gel samples with solvent composition both near and off the critical composition of the free-liquid mixture exhibit similar light-scattering behavior, and (b) a Lorentzian-squared fit to the light-scattering angular distributions yields a characteristic wave number which does not change with temperature and an amplitude which shows a very strong dependence on the temperature.

  15. Reproducibility and signal response linearity of Alanine gel dosimeter

    International Nuclear Information System (INIS)

    Silva, Cleber Feijo Silva; Campos, Leticia Lucente

    2008-01-01

    Gel Dosimetry has been studied mainly for medical applications, because it presents signal response in the dose range used in radiotherapy treatments and it can be applied for three dimensional dosimetry. Alanine gel dosimeter is a new gel material developed at IPEN that presents significant improvement on previous alanine systems developed by Costa (1994). The DL-Alanine (C 3 H 7 NO 2 ) is an amino acid tissue equivalent that improves the production of ferric ions in the solution. These ferric ions concentration can be measured by spectrophotometry technique. This work aims to study the reproducibility of the alanine gel solutions and the signal response as a function of gamma radiation dose, considering that these two properties are very important for characterizing and standardizing any dosimeter. (author)

  16. Radiation effect on polystyrene deposited and grafted on silica gel

    International Nuclear Information System (INIS)

    Kusama, Y.; Udagawa, A.; Takehisa, M.

    1978-01-01

    The effect of radiation on polystyrene was studied in the presence and absence of silica gel by molecular weight measurement with gel permeation chromatography (GPC). Polystyrene crosslinked under vacuum in the absence of silica gel, but it either crosslinked or degraded by radiation, depending on the molecular weight of the polymer in the presence of silica gel. part of the deposited polymer bonded to silica gel by radiation; the G value for graft-chain formation is in the range of 0.01 to 0.1. Irradiation of polystyrene grafted on silica gel resulted in degradation of the graft chain because of the transfer of energy from silica gel. The G value for main chain scission was about 2 when graft polymer was irradiated in the absence of homopolymer. The degradation of graft polymer was suppressed when the polymer was irradiated in the presence of homopolymer, and the amount of unextractable polymer from silica gel increased with increasing irradiation. This adds evidence to the estimation that an increase in grafting percent coupled with a slight decrease in molecular weight at a later stage of radiation-induced polymerization of styrene adsorbed on slica gel is due to a secondary effect of radiation on the polymer

  17. Fibrin Glue Does Not Improve Healing of Gastrointestinal Anastomoses

    DEFF Research Database (Denmark)

    Nordentoft, Tyge; Pommergaard, Hans-Christian; Rosenberg, Jacob

    2015-01-01

    BACKGROUND/AIM: Anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. In order to reduce its incidence, several clinical and experimental studies on anastomotic sealing have been performed. In a number of these studies, the sealing material has been fibrin...... glue (FG), and the results in individual studies have been varying. The positive effect of anastomotic sealing with FG might be due to the mechanical/physical properties, the increased healing of the anastomoses or both. The aim of this systematic review was to evaluate the existing evidence....... It is consequently plausible that the positive effect of FG sealing of gastrointestinal anastomoses, if there is any, may be due to a mechanical sealing effect rather than due to improved healing per se....

  18. Rheology and microstructure of kefiran and whey protein mixed gels.

    Science.gov (United States)

    Kazazi, Hosayn; Khodaiyan, Faramarz; Rezaei, Karamatollah; Pishvaei, Malihe; Mohammadifar, Mohammad Amin; Moieni, Sohrab

    2017-04-01

    The effect of kefiran on cold-set gelation of whey protein isolate (WPI) at 25 °C was studied using rheological measurements and environmental scanning electron microscopy (ESEM). The gelation of samples was induced by the addition of glucono-δ-lactone to the dispersions. WPI concentration was maintained at 8% (w/v) and the concentration of kefiran varied from 0 to 0.08% (w/v). According to rheological measurements, the addition of kefiran into WPI dispersions resulted in a significant increase in the gel strength, the yield stress, and the shear stress values at the flowing point. The gelling point and gelation pH of samples decreased significantly with an increase in kefiran concentration. ESEM micrographs showed that the presence of kefiran played an important role in the microstructure formation of gels. The microstructure of kefiran-WPI mixed gels was more compact and dense, compared to the WPI gel. Depletion interactions between kefiran and whey protein aggregates can be regarded as the chief factor which was responsible for these effects. The present work demonstrated that rheological and microstructural properties of acid-induced whey protein gels were improved by the addition of kefiran.

  19. Improved adhesion and differentiation of endothelial cells on surface-attached fibrin structures containing extracellular matrix proteins

    Czech Academy of Sciences Publication Activity Database

    Filová, Elena; Brynda, Eduard; Riedel, Tomáš; Chlupáč, Jaroslav; Vandrovcová, Marta; Švindrych, Zdeněk; Lisá, Věra; Houska, Milan; Pirk, J.; Bačáková, Lucie

    2014-01-01

    Roč. 102, č. 3 (2014), s. 698-712 ISSN 1549-3296 R&D Projects: GA MZd(CZ) NT11270 Institutional support: RVO:67985823 ; RVO:61389013 Keywords : two-dimensional assembly * fibrin * endothelial cells Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery; CD - Macromolecular Chemistry (UMCH-V) Impact factor: 3.369, year: 2014

  20. Bulk physicochemical, interconnectivity, and mechanical properties of calcium phosphate cements-fibrin glue composites for bone substitute applications

    NARCIS (Netherlands)

    Lopez-Heredia, M.A.; Pattipeilohy, J.; Hsu, S.; Grykien, M.; Weijden, B. van der; Leeuwenburgh, S.C.G.; Salmon, P.; Wolke, J.G.C.; Jansen, J.A.

    2013-01-01

    Calcium phosphate cements (CPCs) and fibrin glue (FG) are used for surgical applications. Their combination is promising to create bone substitutes able to promote cell attachment and bone remodeling. This study proposes a novel approach to create CPC-FG composites by simultaneous CPC setting and FG

  1. Internal structure analysis of particle-double network gels used in a gel organ replica

    Science.gov (United States)

    Abe, Mei; Arai, Masanori; Saito, Azusa; Sakai, Kazuyuki; Kawakami, Masaru; Furukawa, Hidemitsu

    2016-04-01

    In recent years, the fabrication of patient organ replicas using 3D printers has been attracting a great deal of attention in medical fields. However, the cost of these organ replicas is very high as it is necessary to employ very expensive 3D printers and printing materials. Here we present a new gel organ replica, of human kidney, fabricated with a conventional molding technique, using a particle-double network hydrogel (P-DN gel). The replica is transparent and has the feel of a real kidney. It is expected that gel organ replicas produced this way will be a useful tool for the education of trainee surgeons and clinical ultrasonography technologists. In addition to developing a gel organ replica, the internal structure of the P-DN gel used is also discussed. Because the P-DN gel has a complex structure comprised of two different types of network, it has not been possible to investigate them internally in detail. Gels have an inhomogeneous network structure. If it is able to get a more uniform structure, it is considered that this would lead to higher strength in the gel. In the present study we investigate the structure of P-DN gel, using the gel organ replica. We investigated the internal structure of P-DN gel using Scanning Microscopic Light Scattering (SMILS), a non-contacting and non-destructive.

  2. 125I-Fibrin deposition in contact sensitivity reactions in the mouse. Sensitivity of the assay for quantitating reactions after active or passive sensitization

    International Nuclear Information System (INIS)

    Mekori, Y.A.; Dvorak, H.F.; Galli, S.J.

    1986-01-01

    The clotting associated with delayed hypersensitivity (DH) responses in the mouse by sensitizing the animals to the contactant oxazolone (Ox), and then administering 125 I-guinea pig fibrinogen i.v. 10 to 30 min before antigen challenge 5 days later. Early (4 to 8 hr) contact sensitivity (CS) responses in immunized mice were barely detectable by three conventional measures of CS, but the total 125 I-cpm in ears challenged with hapten was 3.6 to 4.5 x that in control ears challenged with vehicle alone; moreover, the amount of urea-insoluble cpm (cross-linked 125 I-fibrin-associated cpm) in the reactions to Ox was 6.5-fold to 8.2-fold that present in the control reactions. In 24 hr reactions that were near peak intensity by measurements of ear swelling, ear weight ratios, and ratios of 125 I-5-iodo-2-deoxyuridine-labeled leukocyte infiltration, the cpm in antigen-challenged ears exceeded that in control ears by 13-fold to 53-fold. In addition, antigen-challenged ears contained 27 to 300 x the urea-insoluble cpm present in control ears. 125 I-Fibrin deposition was not a specific characteristic of CS reactions, because a small amount of urea-insoluble reactivity was also detected in some reactions to Ox in native mice. Nevertheless, the assay was exquisitely sensitive and readily detected quantitative differences between the immunologically specific and nonspecific reactions at very early intervals after challenge or with suboptimal doses of antigen

  3. Polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Baldock, C [Institute of Medical Physics, School of Physics, University of Sydney (Australia); De Deene, Y [Radiotherapy and Nuclear Medicine, Ghent University Hospital (Belgium); Doran, S [CRUK Clinical Magnetic Resonance Research Group, Institute of Cancer Research, Surrey (United Kingdom); Ibbott, G [Radiation Physics, UT M D Anderson Cancer Center, Houston, TX (United States); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, BC (Canada); Lepage, M [Centre d' imagerie moleculaire de Sherbrooke, Departement de medecine nucleaire et de radiobiologie, Universite de Sherbrooke, Sherbrooke, QC (Canada); McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, ON (Canada); Oldham, M [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); Schreiner, L J [Cancer Centre of South Eastern Ontario, Kingston, ON (Canada)], E-mail: c.baldock@physics.usyd.edu.au, E-mail: yves.dedeene@ugent.be

    2010-03-07

    Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented. (topical review)

  4. Applications of gel dosimetry

    International Nuclear Information System (INIS)

    Ibbott, Geoffrey S

    2004-01-01

    Gel dosimetry has been examined as a clinical dosimeter since the 1950s. During the last two decades, however, a rapid increase in the number of investigators has been seen, and the body of knowledge regarding gel dosimetry has expanded considerably. Gel dosimetry is still considered a research project, and the introduction of this tool into clinical use is proceeding slowly. This paper will review the characteristics of gel dosimetry that make it desirable for clinical use, the postulated and demonstrated applications of gel dosimetry, and some complications, set-backs, and failures that have contributed to the slow introduction into routine clinical use

  5. Stability of Beriplast P fibrin sealant: storage and reconstitution.

    Science.gov (United States)

    Eberhard, Ulrich; Broder, Martin; Witzke, Günther

    2006-04-26

    This study was performed to investigate the stability of Beriplast P fibrin sealant (FS) across a range of storage conditions, both pre- and post-reconstitution. Storage stability of the FS was evaluated during long-term refrigeration (24 months) with or without interim storage at elevated temperatures (40 degrees C for 1 week and 25 degrees C for 1 and 3 months). Stability of individual FS components was assessed by measuring: fibrinogen content, Factor XIII activity (FXIII), thrombin activity and aprotinin potency. The package integrity of each component was also checked (sterility testing, moisture content and pH). Storage stability was also evaluated by testing the reconstituted product for adhesion (tearing force testing after mixing the solutions) and sterility. Reconstitution stability was evaluated following 3-months' storage, for up to 50 h post-reconstitution using the same tests as for the storage stability investigations. Pre-defined specifications were met for fibrinogen content, Factor XIII activity, and thrombin activity, demonstrating storage stability. Package integrity and the functionality and sterility of the reconstituted product were confirmed throughout. Reconstitution stability was demonstrated for up to 50 h following reconstitution, in terms of both tearing force and sterility tests. In conclusion, the storage stability of Beriplast P was demonstrated over a range of 24-month storage schedules including interim exposure to elevated temperature, and the reconstituted product was stable for up to 50 h.

  6. Development of poloxamer gel formulations via hot-melt extrusion technology.

    Science.gov (United States)

    Mendonsa, Nicole S; Murthy, S Narasimha; Hashemnejad, Seyed Meysam; Kundu, Santanu; Zhang, Feng; Repka, Michael A

    2018-02-15

    Poloxamer gels are conventionally prepared by the "hot" or the "cold" process. But these techniques have some disadvantages such as high energy consumption, requires expensive equipment and often have scale up issues. Therefore, the objective of this work was to develop poloxamer gels by hot-melt extrusion technology. The model drug selected was ketoprofen. The formulations developed were 30% and 40% poloxamer gels. Of these formulations, the 30% poloxamer gels were selected as ideal gels. DSC and XRD studies showed an amorphous nature of the drug after extrusion. It was observed from the permeation studies that with increasing poloxamer concentration, a decrease in drug permeation was obtained. Other studies conducted for the formulations included in-vitro release studies, texture analysis, rheological studies and pH measurements. In conclusion, the hot-melt extrusion technology could be successfully employed to develop poloxamer gels by overcoming the drawbacks associated with the conventional techniques. Published by Elsevier B.V.

  7. Fabrication and Optimization of a PAGATA Gel Dosimeter: Increasing the Melting Point of the PAGAT Gel Dosimeter with Agarose Additive

    Directory of Open Access Journals (Sweden)

    Bakhtiar Azadbakht

    2010-12-01

    Full Text Available Introduction: The PAGAT polymer gel dosimeter melts at 30 ˚C and even at room temperature during the summer, so it needs to be kept in a cool place such as a refrigerator. To increase the stability of the PAGAT gel, different amounts of agarose were added to the PAGAT gel composition and the PAGATA gel was manufactured. Material and Methods: The PAGATA gel vials were irradiated using a Co-60 machine. Then, the samples were evaluated using a 1.5 T Siemens MRI scanner. The ingredients of the PAGATA normoxic gel dosimeter were 4.5% N-N' methylen-bis-acrylamide, 4.5% acrylamide, 4.5% gelatine, 5 mM tetrakis (THPC, 0.01 mM hydroquinone (HQ, 0.5% agarose and 86% de-ionized water (HPLC. Results: Melting point and sensitivity of the PAGAT gel dosimeter with addition of 0.0, 0.3, 0.5, 1.0, 1.5 and 2.0% of agarose were measured, in which the melting points were increased to 30, 82, 86, 88, 89 and 90°C and their sensitivities found to be 0.113, 0.1059, 0.125, 0.122, 0.115 and 0.2  respectively. Discussion and Conclusions: Adding agarose increased the sensitivity and background R2 of the evaluated samples. The optimum amount of agarose was found to be 0.5% regarding these parameters and also the melting point of the gel dosimeter. A value of 0.5% agarose was found to be an optimum value considering the increase of sensitivity to 0.125 and melting point to 86°C but at the expense of increasing the background R2 to 4.530.

  8. The use of polymer gel dosimetry to measure dose distribution around metallic implants

    International Nuclear Information System (INIS)

    Nagahata, Tomomasa; Yamaguchi, Hajime; Monzen, Hajime; Nishimura, Yasumasa

    2014-01-01

    A semi-solid polymer dosimetry system using agar was developed to measure the dose distribution close to metallic implants. Dosimetry of heterogeneous fields where electron density markedly varies is often problematic. This prompted us to develop a polymer gel dosimetry technique using agar to measure the dose distribution near substance boundaries. Varying the concentration of an oxygen scavenger (tetra-hydroxymethyl phosphonium chloride) showed the absorbed dose and transverse relaxation rate of the magnetic resonance signal to be linear between 3 and 12 Gy. Although a change in the dosimeter due to oxidization was observed in room air after 24 hours, no such effects were observed in the first 4 hours. The dose distribution around the metal implants was measured using agar dosimetry. The metals tested were a lead rod, a titanium hip joint, and a metallic stent. A maximum 30% dose increase was observed near the lead rod, but only a 3% increase in the absorbed dose was noted near the surface of the titanium hip joint and metallic stent. Semi-solid polymer dosimetry using agar thus appears to be a useful method for dosimetry around metallic substances. (author)

  9. [The use of polymer gel dosimetry to measure dose distribution around metallic implants].

    Science.gov (United States)

    Nagahata, Tomomasa; Yamaguchi, Hajime; Monzen, Hajime; Nishimura, Yasumasa

    2014-10-01

    A semi-solid polymer dosimetry system using agar was developed to measure the dose distribution close to metallic implants. Dosimetry of heterogeneous fields where electron density markedly varies is often problematic. This prompted us to develop a polymer gel dosimetry technique using agar to measure the dose distribution near substance boundaries. Varying the concentration of an oxygen scavenger (tetra-hydroxymethyl phosphonium chloride) showed the absorbed dose and transverse relaxation rate of the magnetic resonance signal to be linear between 3 and 12 Gy. Although a change in the dosimeter due to oxidization was observed in room air after 24 hours, no such effects were observed in the first 4 hours. The dose distribution around the metal implants was measured using agar dosimetry. The metals tested were a lead rod, a titanium hip joint, and a metallic stent. A maximum 30% dose increase was observed near the lead rod, but only a 3% increase in the absorbed dose was noted near the surface of the titanium hip joint and metallic stent. Semi-solid polymer dosimetry using agar thus appears to be a useful method for dosimetry around metallic substances.

  10. Removing water from gels

    International Nuclear Information System (INIS)

    Lane, E.S.; Winter, J.A.

    1982-01-01

    Water is removed from a gel material by contacting the gel material with an organic liquid and contacting the organic liquid with a gas such that water is taken up by the gas. The invention, in one embodiment, may be used to dry gel materials whilst maintaining an open porous network therein. In one example, the invention is applied to gel precipitated spheres containing uranium and plutonium. (author)

  11. Analysing uncertainty around costs of innovative medical technologies: the case of fibrin sealant (QUIXIL) for total knee replacement.

    NARCIS (Netherlands)

    Steuten, Lotte Maria Gertruda; Vallejo-Torres, Laura; Bastide, Philippe; Buxton, Martin J.

    2009-01-01

    This paper presents a relatively simple cost model comparing the costs of using a commercial fibrin sealant (QUIXIL®) in addition to conventional haemostatic treatment vs. conventional treatment alone in total knee replacement (TKR) surgery, and demonstrates and discusses how one- and two-way

  12. Categorization of rheological scaling models for particle gels applied to casein gels

    NARCIS (Netherlands)

    Mellema, M.; Opheusden, van J.H.J.; Vliet, van T.

    2002-01-01

    Rennet-induced casein gels made from skim milk were studied rheologically. A scaling model or framework for describing the rheological behavior of gels is discussed and used for classification of the structure of casein gels. There are two main parameters in the model that describe the number of

  13. Antimicrobial properties of single-donor-derived, platelet-leukocyte fibrin for fistula occlusion: An in vitro study.

    Science.gov (United States)

    Wu, Xiuwen; Ren, Jianan; Yuan, Yujie; Luan, Jianfeng; Yao, Genhong; Li, Jieshou

    2013-01-01

    Fibrin glue is a promising alternative for low-output enterocutaneous fistula closure. Bacterial flora colonizing inside the fistula tract, however, may limit the glue application. Single-donor-derived, platelet-rich materials were hypothesized in this study to have antimicrobial activity against Gram-negative microorganisms. Platelet-leukocyte fibrin (PLF), platelet-rich plasma (PRP), and platelet-poor plasma (PPP) were obtained from healthy volunteers. The amounts of platelet, leukocyte, and complement/antibody were determined. In vitro laboratory susceptibility to PLF and plasmas was determined by the Kirby-Bauer disc-diffusion method. Antimicrobial activity of PLF, PRP, and PPP against three Gram-negative ATCC strains was determined in a bacterial kill assay. Levels of complement and antibody did not significantly differ among PLF, PRP, and PPP (p > 0.05), while platelet and leukocyte counts in platelet-rich biomaterials were significantly higher than those in PPP (p platelets and leukocytes may play an important role in bacterial defense. This is the first study to demonstrate the antibacterial properties of single-unit PLF for fistula closure, presenting a new opportunity for glue sealing.

  14. Investigation on safety of gel decontamination technology

    International Nuclear Information System (INIS)

    Liu Zhihui; Song Fengli; Wang Yongxian; Zhang Taoge

    2014-01-01

    Gel decontamination technology is an advanced decontamination process of metal contaminated by radionuclide. It has the advantages such as simple operation process, high decontaminating factor, etc. But the disadvantages are that it has high spraying pressure and is strongly corrosive, which has safety risk to the operator and equipment. The effect of such factors as spraying pressure on operators was analyzed based on process feature, and it is proposed that it be worthwhile to make further study on the corrosion of gels to spraying equipment, taking into account corrosion feature of gels to stainless steel. Meanwhile, the safety issue was demonstrated on collecting and handling wastes from gel decontamination process. And then, protective measures, study methods, and solutions are put forward. The results show that protection should be strengthened during spraying to reduce the effect of splashing and fogging on workers; the equipment should be cleaned in time to reduce the effect of corrosion, and reducers should be added into waste liquid to eliminate the effect of residual detergent. (authors)

  15. Effect of saccharide additives on response of ferrous-agarose-xylenol orange radiotherapy gel dosimeters

    International Nuclear Information System (INIS)

    Healy, B.J.; Zahmatkesh, M.H.; Nitschke, K.N.; Baldock, C.

    2003-01-01

    Glucose, sucrose, starch, and locust bean gum have been used as additives to the ferrous-agarose-xylenol orange (FAX) gel dosimeter. The saccharide enhanced dosimeters were found to have a higher dose sensitivity over a standard FAX gel as measured by both optical density change and magnetic resonance imaging (MRI). With optical density measurement, OD-dose sensitivity increases were up to 55% for glucose, 122% for sucrose and 43% for starch, while locust bean gum did not give a consistent response. With MRI, R 1 -dose sensitivity increases were up to 178% with sucrose addition. The FAX gel with sucrose was studied in greatest detail. The OD-dose sensitivity dependence on cooling rate was reduced for the sucrose FAX gel over the standard FAX gel, which has significant implications for uniform dose sensitivity in large gel phantoms. The thermal oxidation rate in the sucrose FAX gel was up to 2.3 times higher than in the standard gel. The OD-dose sensitivity of oxygenated sucrose FAX gels was 4.3 times greater than standard FAX gels, while continued enhancement in OD-dose sensitivity with increased sucrose concentrations beyond 2.0 g/l was found only for the oxygenated sucrose FAX gels. Both the molar absorption coefficient of the ferric ion-xylenol orange complex at 543 nm and gel pH were not affected by the presence of sucrose, with the implication that the higher OD-dose sensitivity of gels with saccharides is due to increased chain reaction production of ferric ions

  16. Reproducibility of measurement of the environmental carbon-14 samples prepared by the gel suspension method

    International Nuclear Information System (INIS)

    Ohura, Hirotaka; Wakabayashi, Genichiro; Nakamura, Kouji; Okai, Tomio; Matoba, Masaru; Kakiuchi, Hideki; Momoshima, Noriyuki; Kawamura, Hidehisa.

    1997-01-01

    Simple liquid scintillation counting technique for the assay of 14 C in the environment was developed. This technique was done by using gel suspension method, in which sample preparation is very simple and requires no special equipments. The reproducibility of this technique was considered and it was shown that the gel suspension method had enough reproducibility to monitor the environmental 14 C. (author)

  17. Percutaneous sclerotherapy of massive macrocystic lymphatic malformations of the face and neck using fibrin glue with OK-432 and bleomycin.

    Science.gov (United States)

    Chen, W-l; Huang, Z-q; Chai, Q; Zhang, D-m; Wang, Y-y; Wang, H-j; Wang, L; Fan, S

    2011-06-01

    Picibanil (OK-432) and bleomycin have been used as alternative sclerosing agents for lymphatic malformations. This study evaluated the clinical curative effect of sclerotherapy using fibrin glue combined with OK-432 and bleomycin for the treatment of macrocystic lymphatic malformations of the face and neck. Fifteen paediatric patients (6 males; 9 females, aged 13 months to 14 years) who had received percutaneous sclerotherapy for massive macrocystic lymphatic malformations of the face and neck were retrospectively reviewed. Affected regions included the neck, parotid region and parapharynx, mouth floor, face and cheek, and orbital regions. All patients showed preoperative symptoms of space-occupying lesions between 4 cm × 5 cm and 12 cm × 16 cm in size. Fibrin glue with OK-432 and bleomycin was injected under general anaesthesia. All patients received preoperative and follow-up CT scans. Outcomes were assessed by three surgeons. All patients exhibited mid-facial swelling for 3-4 weeks after surgery, but no major complications. Follow-up periods ranged from 8 to 16 months. Eight lesions were completely involuted, five were mostly involuted, and two were partially involuted. Percutaneous sclerotherapy using fibrin glue with OK-432 and bleomycin provided a simple, safe, and reliable alternative treatment for massive macrocystic lymphatic malformations of the face and neck. Copyright © 2011 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Injectable scaffold materials differ in their cell instructive effects on primary human myoblasts

    DEFF Research Database (Denmark)

    Hejbøl, Eva Kildall; Sellathurai, Jeeva; Nair, Prabha Damodaran

    2017-01-01

    Scaffolds are materials used for delivery of cells for regeneration of tissues. They support three-dimensional organization and improve cell survival. For the repair of small skeletal muscles, injections of small volumes of cells are attractive, and injectable scaffolds for delivery of cells offer...... a minimally invasive technique. In this study, we examined in vitro the cell instructive effects of three types of injectable scaffolds, fibrin, alginate, and poly(lactic-co-glycolic acid)-based microparticles on primary human myoblasts. The myoblast morphology and progression in the myogenic program differed......, depending on the type of scaffold material. In alginate gel, the cells obtained a round morphology, they ceased to proliferate, and entered quiescence. In the fibrin gels, differentiation was promoted, and myotubes were observed within a few days in culture, while poly(lactic-co-glycolic acid...

  19. Use of platelet rich fibrin in a fenestration defect around an implant

    Directory of Open Access Journals (Sweden)

    R Vijayalakshmi

    2012-01-01

    Full Text Available Guided bone regeneration (GBR in implant therapy is especially useful for implant placement with dehiscence defects or fenestration defects. In alveolar ridges with marked facial/buccal depressions or in knifeedge alveolar crests, the position and direction of fixture placement is restricted. Improvement of alveolar ridge morphology becomes possible with GBR. This article describes a case in which the fenestration defect around an implant was treated by the application of platelet rich fibrin, a second generation platelet concentrate along with bone graft, and guided tissue regeneration membrane.

  20. Association Between Disruption of Fibrin Sheaths Using Percutaneous Transluminal Angioplasty Balloons and Late Onset of Central Venous Stenosis

    International Nuclear Information System (INIS)

    Ni, Nina; Mojibian, Hamid; Pollak, Jeffrey; Tal, Michael

    2011-01-01

    To compare the rates of central venous stenosis in patients undergoing hemodialysis who underwent disruption of fibrin sheath with percutaneous transluminal angioplasty balloons and those who underwent over-the-wire catheter exchange. This study is a retrospective review of 209 percutaneous transluminal angioplasty balloon disruption and 1304 over-the-wire catheter exchange procedures performed in 753 patients. Approval from the Human Investigations Committee was obtained for this study. Up to 10-year follow-up was performed. A χ 2 test was used to compare the rates of central venous stenosis after balloon disruption versus catheter exchange. A t-test was used to compare time to central venous stenosis development. Of the 753 patients in the study, 127 patients underwent balloon disruption of fibrin sheath and 626 had catheter exchange. Within the balloon disruption group, 18 (14.2%) of 127 patients subsequently developed central venous stenosis, compared with 44 (7.0%) of 626 in the catheter exchange group (P 2 test). Time to central venous stenosis development was approximately 3 years in both groups and not significantly different (1371 and 1010 days, P = 0.20). A total of 25.2% of patients in the balloon disruption group had four or more subsequent catheter exchanges, versus 12.6% in the catheter exchange group (P 2 test). In conclusions, there is a possible association between percutaneous transluminal angioplasty balloon disruption of fibrin sheath and late-onset central venous stenosis. Because venography was not routinely performed in catheter exchange patients, future randomized studies are necessary to confirm these findings.

  1. Evaluation of Fibrin Sealants and Tissue Adhesives in Oral Surgery for Patients with Bleeding Disorders

    Directory of Open Access Journals (Sweden)

    Gülsüm Ak

    2012-03-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the efficiency of two local haemostatic agents administered together with preoperative dose of replacement therapy for oral surgical procedures in patients with bleeding disorders METHODS: Twenty-one patients were divided into three groups randomly. Patients in Group 1 (n=7 received preoperative replacement therapy with postoperative fibrin sealant application in the surgical site. Patients in Group 2 (n=7 received preoperative replacement therapy with postoperative tissue adhesive application in the surgical site. Patients in Group 3 (n=7 were given total dose of replacement therapy pre- and postoperatively. RESULTS: No postoperative bleeding was observed in 17 patients including five patients in Group 1 (71.42%, six patients in Group 2 (85.71% and six patients in Group 3 (85.71%. Haemorrhagic complication was observed in only four patients among all groups. CONCLUSION: We conclude that utilization of fibrin sealants and tissue adhesives in oral surgery is beneficial due to the lessened amount of factor concentrates used for replacement therapy and the rapid haemostasis at the operation side to perform serial surgical procedures in the same session.

  2. Photocrosslinkable Gelatin/Tropoelastin Hydrogel Adhesives for Peripheral Nerve Repair.

    Science.gov (United States)

    Soucy, Jonathan R; Shirzaei Sani, Ehsan; Portillo Lara, Roberto; Diaz, David; Dias, Felipe; Weiss, Anthony S; Koppes, Abigail N; Koppes, Ryan A; Annabi, Nasim

    2018-05-09

    Suturing peripheral nerve transections is the predominant therapeutic strategy for nerve repair. However, the use of sutures leads to scar tissue formation, hinders nerve regeneration, and prevents functional recovery. Fibrin-based adhesives have been widely used for nerve reconstruction, but their limited adhesive and mechanical strength and inability to promote nerve regeneration hamper their utility as a stand-alone intervention. To overcome these challenges, we engineered composite hydrogels that are neurosupportive and possess strong tissue adhesion. These composites were synthesized by photocrosslinking two naturally derived polymers, gelatin-methacryloyl (GelMA) and methacryloyl-substituted tropoelastin (MeTro). The engineered materials exhibited tunable mechanical properties by varying the GelMA/MeTro ratio. In addition, GelMA/MeTro hydrogels exhibited 15-fold higher adhesive strength to nerve tissue ex vivo compared to fibrin control. Furthermore, the composites were shown to support Schwann cell (SC) viability and proliferation, as well as neurite extension and glial cell participation in vitro, which are essential cellular components for nerve regeneration. Finally, subcutaneously implanted GelMA/MeTro hydrogels exhibited slower degradation in vivo compared with pure GelMA, indicating its potential to support the growth of slowly regenerating nerves. Thus, GelMA/MeTro composites may be used as clinically relevant biomaterials to regenerate nerves and reduce the need for microsurgical suturing during nerve reconstruction.

  3. Fibrin(ogen) is internalized and degraded by activated human monocytoid cells via Mac-1 (CD11b/CD18): a nonplasmin fibrinolytic pathway.

    Science.gov (United States)

    Simon, D I; Ezratty, A M; Francis, S A; Rennke, H; Loscalzo, J

    1993-10-15

    Fibrin(ogen) (FGN) is important for hemostasis and wound healing and is cleared from sites of injury primarily by the plasminogen activator system. However, there is emerging evidence in plasminogen activator-deficient transgenic mice that nonplasmin pathways may be important in fibrin(ogen)olysis, as well. Given the proximity of FGN and monocytes within the occlusive thrombus at sites of vascular injury, we considered the possibility that monocytes may play an ancillary role in the degradation and clearance of fibrin. We found that monocytes possess an alternative fibrinolytic pathway that uses the integrin Mac-1, which directly binds and internalizes FGN, resulting in its lysosomal degradation. At 4 degrees C, FGN binds to U937 monocytoid cells in a specific and saturable manner with a kd of 1.8 mumol/L. Binding requires adenosine diphosphate stimulation and is calcium-dependent. At 37 degrees C, FGN and fibrin monomer (FM) are internalized and degraded at rates of 0.37 +/- 0.13 and 0.55 +/- 0.03 microgram/10(6) cells/h by U937 cells, 1.38 +/- 0.02 and 1.20 +/- 0.30 microgram/10(6) cells/h by THP-1 cells, and 2.10 +/- 0.20 and 2.52 +/- 0.18 micrograms/10(6) cells/h by human peripheral blood mononuclear cells, respectively. The serine protease inhibitors, PPACK and aprotinin, and the specific elastase inhibitor, AAPVCK, do not significantly inhibit degradation. However, degradation is inhibited by chloroquine, suggesting that a lysosomal pathway is involved. Factor X, a competitive ligand with FGN for the Mac-1 receptor, also blocks degradation, as does a monoclonal antibody to the alpha-subunit of Mac-1. Autoradiography of radioiodinated, internalized FGN shows that FGN proteolysis by the pathway produces a unique degradation pattern distinct from that observed with plasmin. In a fibrin clot lysis assay, Mac-1-mediated fibrinolysis contributed significantly to total fibrinolysis. In summary, FGN is internalized and degraded by activated human monocytoid cells via

  4. Strippable gel for decontamination of contaminated metallic surfaces

    International Nuclear Information System (INIS)

    Banerjee, D.; Sandhya, U.; Khot, S.A.; Srinivas, C.; Wattal, P.K.

    2013-01-01

    Periodic decontamination of radioactive laboratories including fume hoods, glove boxes and all surfaces used for handling, processing and transporting radioactive materials is mandatory in all nuclear installations as this reduces spread of contamination and decreases total man rem exposure. Conventionally, chemical decontaminating agents or surfactant solutions are used for this purpose. However, this approach leads to generation of large volume of secondary radioactive waste. The use of strippable gel is an attractive alternative with low secondary waste generation particularly where removal of loose or weakly fixed contamination is necessary and also when the decontaminated material are to be reused, for e.g. decontamination of fume hoods, glove boxes, transport casks, spent fuel storage racks, control rod drive transport containers etc. Literature on gel formulations is scarce and mostly in the patent form. The sustained effort on gel formulation development has resulted in a basic gel formulation. The gel is a highly viscous water-based organic polymer, particularly suitable for application on vertical surfaces including difficult to reach metallic surfaces of complex geometry and not just limited to horizontal surfaces. The gel can be easily applied on contaminated surfaces by brushing or spraying. Curing of the gel is complete within 16-24 hours under ambient conditions and can then be removed by peeling as a dry sheet. While curing, the contaminants are trapped in gel either physically or chemically depending upon the nature of the contaminant. Salient features of cured gel include that it is water soluble and can be disposed off after immobilization in cement. Decontamination performance of the gel was initially evaluated by applying it on SS planchettes contaminated with known amount of radionuclides such as Cs(I), Co(II) and Ce(III). The measured decontamination factor was found to be in the range of 50-500, lowest for Ce(III) and highest for Co

  5. 3-D dose verification for IMRT using optical CT based polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Wuu, C [Department of Radiation Oncology, Columbia University, New York, New York (United States); Xu, Y [Department of Radiation Oncology, Columbia University, New York, New York (United States); Maryanski, M J [Department of Radiation Oncology, Columbia University, New York, New York (United States); MGS Research Inc., Madison, Connecticut (United States)

    2004-01-01

    In this study BANG[reg] polymer gels in conjunction with OCTOPUS{sup TM} optical CT scanner (MGS Research Inc., Madison, CT) was employed to measure the relative 3D dose distribution of an IMRT treatment. Measured relative dose distributions from the gel measurement were compared with those from treatment planning system calculations and EDR2 film measurements with regard to planar dose distributions in axial, coronal, and sagittal orientations.

  6. 3-D dose verification for IMRT using optical CT based polymer gel dosimetry

    International Nuclear Information System (INIS)

    Wuu, C; Xu, Y; Maryanski, M J

    2004-01-01

    In this study BANG[reg] polymer gels in conjunction with OCTOPUS TM optical CT scanner (MGS Research Inc., Madison, CT) was employed to measure the relative 3D dose distribution of an IMRT treatment. Measured relative dose distributions from the gel measurement were compared with those from treatment planning system calculations and EDR2 film measurements with regard to planar dose distributions in axial, coronal, and sagittal orientations

  7. Detection of ultraviolet radiation using tissue equivalent radiochromic gel materials

    International Nuclear Information System (INIS)

    Bero, M A; Abukassem, I

    2009-01-01

    Ferrous Xylenol-orange Gelatin gel (FXG) is known to be sensitive to ionising radiation such as γ and X-rays. The effect of ionising radiation is to produce an increase in the absorption over a wide region of the visible spectrum, which is proportional to the absorbed dose. This study demonstrates that FXG gel is sensitive to ultraviolet radiation and therefore it could functions as UV detector. Short exposure to UV radiation produces linear increase in absorption measured at 550nm, however high doses of UV cause the ion indicator colour to fad away in a manner proportional to the incident UV energy. Light absorbance increase at the rate of 1.1% per minute of irradiation was monitored. The exposure level at which the detector has linear response is comparable to the natural summer UV radiation. Evaluating the UV ability to pass through tissue equivalent gel materials shows that most of the UV gets absorbed in the first 5mm of the gel materials, which demonstrate the damaging effects of this radiation type on human skin and eyes. It was concluded that FXG gel dosimeter has the potential to offer a simple, passive ultraviolet radiation detector with sensitivity suitable to measure and visualises the natural sunlight UV exposure directly by watching the materials colour changes.

  8. Detection of ultraviolet radiation using tissue equivalent radiochromic gel materials

    Science.gov (United States)

    Bero, M. A.; Abukassem, I.

    2009-05-01

    Ferrous Xylenol-orange Gelatin gel (FXG) is known to be sensitive to ionising radiation such as γ and X-rays. The effect of ionising radiation is to produce an increase in the absorption over a wide region of the visible spectrum, which is proportional to the absorbed dose. This study demonstrates that FXG gel is sensitive to ultraviolet radiation and therefore it could functions as UV detector. Short exposure to UV radiation produces linear increase in absorption measured at 550nm, however high doses of UV cause the ion indicator colour to fad away in a manner proportional to the incident UV energy. Light absorbance increase at the rate of 1.1% per minute of irradiation was monitored. The exposure level at which the detector has linear response is comparable to the natural summer UV radiation. Evaluating the UV ability to pass through tissue equivalent gel materials shows that most of the UV gets absorbed in the first 5mm of the gel materials, which demonstrate the damaging effects of this radiation type on human skin and eyes. It was concluded that FXG gel dosimeter has the potential to offer a simple, passive ultraviolet radiation detector with sensitivity suitable to measure and visualises the natural sunlight UV exposure directly by watching the materials colour changes.

  9. Screening of mucoadhesive vaginal gel formulations

    Directory of Open Access Journals (Sweden)

    Ana Ochoa Andrade

    2014-12-01

    Full Text Available Rational design of vaginal drug delivery formulations requires special attention to vehicle properties that optimize vaginal coating and retention. The aim of the present work was to perform a screening of mucoadhesive vaginal gels formulated with carbomer or carrageenan in binary combination with a second polymer (carbomer, guar or xanthan gum. The gels were characterised using in vitroadhesion, spreadability and leakage potential studies, as well as rheological measurements (stress and frequency sweep tests and the effect of dilution with simulated vaginal fluid (SVF on spreadability. Results were analysed using analysis of variance and multiple factor analysis. The combination of polymers enhanced adhesion of both primary gelling agents, carbomer and carrageenan. From the rheological point of view all formulations presented a similar behaviour, prevalently elastic and characterised by loss tangent values well below 1. No correlation between rheological and adhesion behaviour was found. Carbomer and carrageenan gels containing the highest percentage of xanthan gum displayed good in vitro mucoadhesion and spreadability, minimal leakage potential and high resistance to dilution. The positive results obtained with carrageenan-xanthan gum-based gels can encourage the use of natural biocompatible adjuvants in the composition of vaginal products, a formulation field that is currently under the synthetic domain.

  10. Metal-silica sol-gel materials

    Science.gov (United States)

    Stiegman, Albert E. (Inventor)

    2002-01-01

    The present invention relates to a single phase metal-silica sol-gel glass formed by the co-condensation of a transition metal with silicon atoms where the metal atoms are uniformly distributed within the sol-gel glass as individual metal centers. Any transition metal may be used in the sol-gel glasses. The present invention also relates to sensor materials where the sensor material is formed using the single phase metal-silica sol-gel glasses. The sensor materials may be in the form of a thin film or may be attached to an optical fiber. The present invention also relates to a method of sensing chemicals using the chemical sensors by monitoring the chromatic change of the metal-silica sol-gel glass when the chemical binds to the sensor. The present invention also relates to oxidation catalysts where a metal-silica sol-gel glass catalyzes the reaction. The present invention also relates to a method of performing oxidation reactions using the metal-silica sol-gel glasses. The present invention also relates to organopolymer metal-silica sol-gel composites where the pores of the metal-silica sol-gel glasses are filled with an organic polymer polymerized by the sol-gel glass.

  11. Study of nuclear glasses alteration gel and synthesis of some model gels; Etude du gel d`alteration des verres nucleaires et synthese de gels modeles

    Energy Technology Data Exchange (ETDEWEB)

    Ricol, S

    1995-10-05

    This work deals with the general problem of alteration of the reference nuclear glass R7T7. Attention is paid particularly to the altered layer formed at the glass surface during alteration process. In opposition to previous works, related essentially to glass dissolution kinetics based on chemical analyses of lixiviated elements, this thesis deals with alteration problems through structural studies of the reference glass and derived gel. This approach allows the determination of mechanisms for the gel formation and a better understanding of the behaviour of glasses towards lixiviation. Both approaches appeared complementary. Based on several spectroscopic techniques, this work showed the particular role of cations such as calcium, zirconium and iron. Studies of silica-based synthetic gels showed the synergic effect of formers cation and of one highly coordinated cation. The variation of the wavenumber related to Si-O-Si asymmetric stretching vibration can be correlated to O/Si ratio for ternary systems Si/Na/Zr. On the contrary, the Si losses of the materials depend on the number of non-bridging oxygen atoms. In the perspective of long-term behaviour, the alteration gel presents better characteristics than initial glass. It is therefore a highly stable material in static conditions. In the same way, synthetic gels are materials with very low solubilities (much lower than the alteration gel) and could be used as confining matrices. (authors). refs., 71 figs., 37 tabs.

  12. Thoria sol-gel processes

    International Nuclear Information System (INIS)

    Matthews, R.B.

    1978-10-01

    Alternate fuel fabrication techniques are being developed at WNRE as part of the thorium fuel cycle program. The sol-gel techniques are attractive and this report assembles and summarizes information relating to thoria sol-gel fuels. Some background information on the behaviour and advantages of sol-gel fuel forms is presented, followed by a review of relevant colloid chemistry and an explanation of the fundamental steps of sol-gel processes. Finally, several variants to the basic process are reviewed and evaluated. (author)

  13. Review of Fricke gel dosimeters

    International Nuclear Information System (INIS)

    Schreiner, L J

    2004-01-01

    The innovation of adding a gel matrix to the traditional Fricke dosimeter to stabilize geometric information established the field of gel dosimetry for radiation therapy. A discussion of Fricke gels provides an overview of the issues that determine the dose response of all gel dosimeters in general. In this paper we review some of the features of Fricke systems to illustrate these issues and, in addition, to motivate renewed clinical interest in Fricke gels

  14. Unfolding of hemoglobin variants--insights from urea gradient gel electrophoresis photon correlation spectroscopy and zeta potential measurements

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, Jaydeep; GhoshMoulick, Ranjita; Choudhuri, Utpal; Chakrabarty, Prantar; Bhattacharya, Pranab K.; Lahiri, Prabir; Chakraborti, Bikas; Dasgupta, Anjan Kr

    2004-09-27

    The unfolding pattern of crystal human hemoglobin and variants of hemoglobin obtained from hemolysate were studied using transverse urea gradient gel electrophoresis (TUGGE). A smooth sigmoid like increase of electrophoretic mobility was observed with increasing urea concentrations. A decrease in electrophoretic mobility resulted, if the protein was unfolded with guanidium hydrochloride (GdnHCl). The anomaly was resolved after the Stoke's radii (obtained using the photon correlation spectroscopy) and zeta potential (measured using laser Doppler velocimetry) measurements were made at different denaturant concentrations. Addition of denaturant led to formation of extended structure, irrespective of the nature of the denaturant, as indicated by increase in Stoke's radii in both cases (urea and GdnHCl). The unexpected increase in electrophoretic mobility in case of urea could be explained in terms of a critical redistribution of negative charge at intermediate stages of the unfolding process. In case of GdnHCl, the higher ionic strength masked the charge effect. The mobility, being solely dependent on size, decreased at higher denaturant concentration. Incidentally, folding loci of other hemoglobin variants (e.g. HbE) or that of post-translationally modified hemoglobin (e.g. HbA1c) could be determined by studying the charge distribution and hydrodynamic radius at varying denaturing stress and in each case the gel migration profile could be approximately scaled by the ratio of charge and hydrodynamic diameter of the protein. While unfolding induced charge effect was most pronounced in HbA0 (and crystal ferrous hemoglobin), the unfolding induced aggregation (manifested by the increase in Stoke's radii) was predominantly observed in the variant forms HbE and HbA1c. Representing the proteins by a plot, in which charge and hydrodynamic diameter are on independent axes, may be a useful way of characterizing protein variants having similar migration profiles on

  15. Gel nano-particulates against radioactivity; Des nanoparticules en gel contre la radioactivite

    Energy Technology Data Exchange (ETDEWEB)

    Deroin, Ph

    2004-11-01

    The Argonne research center (USA) has developed a 'super-gel' compound, a polymer close to those used in baby's diapers, which can reach a 90% efficiency in the radioactive decontamination of porous materials, like bricks or concrete. The contaminated materials are sprayed with a mixture of polymer gel and wetting agent with nano-particulates in suspension. Under the action of the wetting agent, radioactivity migrates from the pores to the gel and is trapped by the nano-particulates. The drying and recycling of the gel allows to reduce the volume of radioactive wastes. Short paper. (J.S.)

  16. Feasibility of quantitative PET/CT dosimetry for proton therapy using polymer gels

    Energy Technology Data Exchange (ETDEWEB)

    Zeidan, O A; Hsi, W C; Lopatiuk-Tirpak, O; Sriprisan, S I; Meeks, S L; Kupelian, P A; Li, Z; Palta, J R, E-mail: lenatirpak@gmail.co

    2010-11-01

    A feasibility study of proton beam PET/CT off-line quantitative dosimetry using polymer gels is presented. A newly developed proton-sensitive polymer gel dosimeter (BANG( (registered)) 3-Pro2) is used as a dosimeter and a tissue-equivalent phantom medium for this study. We explore a new approach to correlating measured proton 3-dimensional (3D) dose distributions directly to measured positron emission from in the gel medium using PET/CT imaging. A large cylindrical volume (2.2 Litres) of the gel was irradiated with a clinical modulated proton beam using irregular-shaped aperture geometry. The gel was imaged in a nearby PET/CT unit immediately (<3 min) after irradiation. Dose distribution in the gel was generated using an optical tomography scanning system. Direct 3D spatial comparison of dose and positron emission distributions was then performed. Profiles along the beam path show that the distal fall-off of the dose is nearly 2 cm deeper than the activity profile which is comparable to previous studies with plastic phantoms and Monte Carlo simulations of activity distributions. Planar PET and dose distributions at depth and perpendicular to beam axis show a strong one-to-one spatial correlation. This phantom study demonstrates that the gel medium could be potentially useful for quantifying various physical factors that can influence the PET activity range verification method in patients.

  17. Charge-regularized swelling kinetics of polyelectrolyte gels: Elasticity and diffusion

    Science.gov (United States)

    Sen, Swati; Kundagrami, Arindam

    2017-11-01

    We apply a recently developed method [S. Sen and A. Kundagrami, J. Chem. Phys. 143, 224904 (2015)], using a phenomenological expression of osmotic stress, as a function of polymer and charge densities, hydrophobicity, and network elasticity for the swelling of spherical polyelectrolyte (PE) gels with fixed and variable charges in a salt-free solvent. This expression of stress is used in the equation of motion of swelling kinetics of spherical PE gels to numerically calculate the spatial profiles for the polymer and free ion densities at different time steps and the time evolution of the size of the gel. We compare the profiles of the same variables obtained from the classical linear theory of elasticity and quantitatively estimate the bulk modulus of the PE gel. Further, we obtain an analytical expression of the elastic modulus from the linearized expression of stress (in the small deformation limit). We find that the estimated bulk modulus of the PE gel decreases with the increase of its effective charge for a fixed degree of deformation during swelling. Finally, we match the gel-front locations with the experimental data, taken from the measurements of charged reversible addition-fragmentation chain transfer gels to show an increase in gel-size with charge and also match the same for PNIPAM (uncharged) and imidazolium-based (charged) minigels, which specifically confirms the decrease of the gel modulus value with the increase of the charge. The agreement between experimental and theoretical results confirms general diffusive behaviour for swelling of PE gels with a decreasing bulk modulus with increasing degree of ionization (charge). The new formalism captures large deformations as well with a significant variation of charge content of the gel. It is found that PE gels with large deformation but same initial size swell faster with a higher charge.

  18. Design of Autonomous Gel Actuators

    Directory of Open Access Journals (Sweden)

    Shuji Hashimoto

    2011-01-01

    Full Text Available In this paper, we introduce autonomous gel actuators driven by chemical energy. The polymer gels prepared here have cyclic chemical reaction networks. With a cyclic reaction, the polymer gels generate periodical motion. The periodic motion of the gel is produced by the chemical energy of the oscillatory Belouzov-Zhabotinsky (BZ reaction. We have succeeded in making synthetic polymer gel move autonomously like a living organism. This experimental fact represents the great possibility of the chemical robot.

  19. Experimental determination of order in non-equilibrium solids using colloidal gels

    International Nuclear Information System (INIS)

    Gao Yongxiang; Kilfoil, Maria

    2004-01-01

    The idea of quantifying order in disordered systems has been introduced recently by Torquato and co-workers (2000 Phys. Rev. E 62 993-1001). We are interested in the application of this idea to measure structure in non-equilibrium systems. Here we focus on gels, using as a model system colloidal gels formed from hard spheres with polymer added to the systems to induce a controlled, weak attraction. To describe the structure of the gels we use real space imaging via confocal microscopy to obtain the full three-dimensional structure. We measure experimentally both translational order and bond angle correlations, defining a new (refined) translational order parameter that is sensitive to long range order in these non-random packings. This metric is also sensitive to anisotropy, which should be important in the many physical situations where an external force is present. The bond angle distribution shows coordinated organization. To give a clearer physical picture for gels, we compare the experimental data to computer generated hard sphere systems

  20. Optimal processing for gel electrophoresis images: Applying Monte Carlo Tree Search in GelApp.

    Science.gov (United States)

    Nguyen, Phi-Vu; Ghezal, Ali; Hsueh, Ya-Chih; Boudier, Thomas; Gan, Samuel Ken-En; Lee, Hwee Kuan

    2016-08-01

    In biomedical research, gel band size estimation in electrophoresis analysis is a routine process. To facilitate and automate this process, numerous software have been released, notably the GelApp mobile app. However, the band detection accuracy is limited due to a band detection algorithm that cannot adapt to the variations in input images. To address this, we used the Monte Carlo Tree Search with Upper Confidence Bound (MCTS-UCB) method to efficiently search for optimal image processing pipelines for the band detection task, thereby improving the segmentation algorithm. Incorporating this into GelApp, we report a significant enhancement of gel band detection accuracy by 55.9 ± 2.0% for protein polyacrylamide gels, and 35.9 ± 2.5% for DNA SYBR green agarose gels. This implementation is a proof-of-concept in demonstrating MCTS-UCB as a strategy to optimize general image segmentation. The improved version of GelApp-GelApp 2.0-is freely available on both Google Play Store (for Android platform), and Apple App Store (for iOS platform). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Gel Dosimetry Analysis of Gold Nanoparticle Application in Kilovoltage Radiation Therapy

    International Nuclear Information System (INIS)

    Marques, T; Schwarcke, M; Garrido, C; Zucolot, V; Baffa, O; Nicolucci, P

    2010-01-01

    In this work gold nanoparticles (AuNP) were embedded in MAGIC-f gel and irradiated in a 250 kV x-ray clinical beam. The signal of non-irradiated gel samples containing AuNPs showed maximum difference of 0.5% related to gel without nanoparticles. Different AuNPs concentrations were studied: 0.10 mM, 0.05 mM and 0.02 mM, presenting dose enhancements of 106%, 90% and 77% respectively. Monte Carlo spectrometry was performed to quantify theoretical changes in photon energy spectrums due to AuNPs presence. Concordance between simulated dose enhancements and gel dosimetry measurements was better than 97% to all concentrations studied. This study evidences that polymer gel dosimetry as a suitable tool to perform dosimetric investigations of nanoparticle applications in Radiation Therapy.

  2. Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: a prospective randomized blinded study.

    Science.gov (United States)

    Moser, C; Opitz, I; Zhai, W; Rousson, V; Russi, E W; Weder, W; Lardinois, D

    2008-10-01

    Prolonged air leak is reported in up to 50% of patients after lung volume reduction surgery. The effect of an autologous fibrin sealant on the intensity and duration of air leak and on the time to chest drain removal after lung volume reduction surgery was investigated in a randomized prospective clinical trial. Twenty-five patients underwent bilateral thoracoscopic lung volume reduction surgery. In each patient, an autologous fibrin sealant was applied along the staple lines on one side, whereas no additional measure was taken on the other side. Randomization of treatment was performed at the end of the resection on the first side. Air leak was assessed semiquantitatively by use of a severity score (0 = no leak; 4 = continuous severe leak) by two investigators blinded to the treatment. Mean value of the total severity scores for the first 48 hours postoperative was significantly lower in the treated group (4.7 +/- 7.7) than in the control group (16.0 +/- 10.1) (P drainage were also significantly reduced after application of the sealant (4.5% and 2.8 +/- 1.9 days versus 31.8% and 5.9 +/- 2.9 days) (P = .03 and P drainage.

  3. Comparative Evaluation of Pain Scores during Periodontal Probing with or without Anesthetic Gels.

    Science.gov (United States)

    Mishra, Ashank; Priyanka, Mandapathi; Pradeep, Koppolu; Reddy Pathakota, Krishnajaneya

    2016-01-01

    Context. The initial periodontal examination which includes full-mouth periodontal probing is one of the discomforting procedures for a patient. Aim. To evaluate the efficacy of two local anesthetic gels in the reduction of pain during periodontal probing using Florida probe in CGP patients in comparison with manual probing. Materials and Methods. Ninety systemically healthy patients with moderate to severe CGP patients were recruited. In each patient, the quadrants were randomly assigned to manual probing with UNC-15 probe, probing with Florida probe, and Florida probing with lidocaine 10% gel and with benzocaine 20% gel. In the quadrants undergoing probing with anesthetic gels, the sites were isolated and the gel was injected using syringe and a blunt-end cannula. Pain was measured using 10 mm horizontal VAS. Statistical Analysis. The analysis was carried out using SPSS version 18. The comparison of mean VAS scores was done using repeated measures ANOVA with post hoc Bonferroni test. Results. Mean VAS for manual probing was significantly more than Florida probing. Further, the mean VAS score for Florida probing was higher than the two gels. Conclusion. It is suggested that the gels might be useful in reducing pain experienced during full-mouth periodontal probing in patients with CGP.

  4. Potential for Osseous Regeneration of Platelet-Rich Fibrin-A Comparative Study in Mandibular Third Molar Impaction Sockets.

    Science.gov (United States)

    Varghese, Mathew P; Manuel, Suvy; Kumar L K, Surej

    2017-07-01

    This study investigated the potential of platelet-rich fibrin (PRF) for osseous regeneration and soft tissue healing in mandibular third molar impaction sockets. A prospective in vivo study was performed. Randomization was performed after extraction. On one side, the socket was sutured primarily (control site); on the other side, autologous PRF gel was placed and then the socket was sutured (test site). Postoperatively, grid periapical radiographs were obtained at periodic intervals (weeks 1, 4, and 16) and digitalized. Gray-level values were measured at 3 different regions of the socket (for regions of newly formed bone) compared with the natural bone area using HL Image++ software, and the percentage bone fill was measured. Clinical evaluation of soft tissue healing was performed using the healing index of Landry et al (J Periodontol 60:212, 1994) at the specific intervals. Thirty healthy men and women (age range, 18 to 35 yr) with bilaterally impacted mandibular third molars were enrolled in this study. In general, there was markedly greater bone formation in sockets treated with PRF (P < .05). In the PRF group, the average gray-level values at the cervical, middle, and apical regions were 61.85 (standard deviation [SD], ±25.186), 64.54 (SD, ±24.831), and 67.80 (SD, ±23.946), respectively, with a mean value of 64.73 (SD, ±24.411). In the control group, these values were 51.58 (SD, ±15.286), 54.30 (SD, ±16.274), and 57.53 (SD, ±16.187), respectively, with a mean of 53.67 (SD, ±16.528). The average percentage of bone fill in the PRF group was 57.90 (SD, ±26.789) and that of the non-PRF group was 46.74 (SD, ±17.713; P < .05). Soft tissue healing as evaluated by the healing index of Landry et al also was found to be better at the PRF test site and it was statistically significant (P < .05). There was evidence for better osseous regeneration and soft tissue healing in response to PRF. Further investigations to evaluate the application of PRF in other

  5. Effect of fibrin-binding synthetic oligopeptide on the healing of full-thickness skin wounds in streptozotocin-induced diabetic rats.

    Science.gov (United States)

    Chung, Jae-Eun; Kim, Yun-Jeong; Park, Yoon-Jeong; Koo, Ki-Tae; Seol, Yang-Jo; Lee, Yong-Moo; Rhyu, In-Chul; Ku, Young

    2013-01-01

    The aim of this study was to investigate whether topical application of fibrin-binding oligopeptides derived from FN promotes wound healing in streptozotocin (STZ)-induced diabetic rats. Oligopeptides including fibrin-binding sequences (FF3: CFDKYTGNTYRV, FF5 : CTSRNRCNDQ) of FN repeats were synthesized. Each peptide was loaded in 15 x 15 mm fibrous alginate dressings, and the release kinetics of the peptides was evaluated using trinitrobenzene sulfonic acid for 336 hours. Two full-thickness cutaneous wounds were prepared on the dorsal skin of each 75 diabetes induced rats. Each wound was divided into FF3-loaded alginate dressing group, FF5-loaded alginate dressing group, alginate dressing group and negative control group. Animals were sacrificed at day 0,3,7 and 14. The wound closure rate, inflammation degree, expression of TGF-β1 and hydroxyproline contents were evaluated. Both FF3 and FF5 peptides were released rapidly within the first 24 hours. FF3-loaded dressing treated wounds closed significantly faster than other wounds at day 3. And at day 14, FF3- & FF5- loaded dressing treated wounds demonstrated less inflammatory cells infiltration than alginate dressing treated and negative group wounds. TGF-β1 positive cells were more abundant in FF3-, FF5-treated alginate dressing treated wound at day 3 and 14. At last, the hyrdroxyproline contents in the FF3, FF5 group were higher at day 7 and day 14. Topical application of fibrin-binding domain synthetic oligopeptides from FN resulted in acceleration of full-thickness cutaneous wound healing in diabetic rats.

  6. An investigation of the chemical stability of a monomer/polymer gel dosimeter

    International Nuclear Information System (INIS)

    De Deene, Y.; De Wagter, C.; De Neve, W.; Achten, E.

    2000-01-01

    The aim of this work is to investigate the temporal stability of a polyacrylamide gelatin hydrogel used for 3D monomer/polymer gel dosimetry techniques involving different methods of analysis. Long-term instabilities for a similar gel have recently been reported, but differ markedly from those described in this work. Two kinds of long-term instabilities are described. One affects the slope of the dose-R 2 plot and is related to post-irradiation polymerization of the comonomer/polymer aggregates. It is observed that post-irradiation polymerization only lasts 12 hours after irradiation. The other instability affects the intercept of the dose-R 2 plot, lasts for up to 30 days and is related to the gelation process of gelatin. Further studies were performed on gelatin gels of varying compositions to obtain a better understanding of the molecular mechanism that causes the instability due to gelation. The studies included observations of the spin-spin and spin-lattice relaxation rates in combination with diffusion measurements and optical measurements. It is shown that the heating history during the manufacture of the gel affects the absolute R 2 value of the gel but not its variation. The findings presented in this study may help in producing more stable and reproducible monomer/polymer gel dosimeters. (author)

  7. Growth of hydroxyapatite on physiologically clotted fibrin capped gold nanoparticles

    International Nuclear Information System (INIS)

    Sastry, T P; Sundaraseelan, J; Swarnalatha, K; Sobhana, S S Liji; Makheswari, M Uma; Sekar, S; Mandal, A B

    2008-01-01

    The growth of hydroxyapatite (HAp) on physiologically clotted fibrin (PCF)-gold nanoparticles is presented for the first time by employing a wet precipitation method. Fourier transform infrared (FTIR) spectroscopy confirmed the characteristic functionalities of PCF and HAp in the PCF-Au-HAp nanocomposite. Scanning electron microscopy (SEM) images have shown cuboidal nanostructures having a size in the range of 70-300 nm of HAp, whereas 2-50 nm sized particles were visualized in high-resolution transmission electron microscopy (TEM). Energy-dispersive x-ray (EDX) and x-ray diffraction (XRD) studies have confirmed the presence of HAp. These results show that gold nanoparticles with PCF acted as a matrix for the growth of HAp, and that PCF-Au-HAp nanocomposite is expected to have better osteoinductive properties

  8. Polymer gels and networks

    National Research Council Canada - National Science Library

    Osada, Yoshihito; Khokhlov, A. R

    2002-01-01

    ... or magnetic field, etc.). It was realized that not only can polymer gels absorb and hold a considerable volume of liquids, but they can also be forced to expel the absorbed liquid in a controlled manner. Of particular interest are hydrogels, i.e., polymer gels, which swell extensively in water. The most common hydrogels are polyelectrolyte gels: ...

  9. Complex interactions between human myoblasts and the surrounding 3D fibrin-based matrix.

    Directory of Open Access Journals (Sweden)

    Stéphane Chiron

    Full Text Available Anchorage of muscle cells to the extracellular matrix is crucial for a range of fundamental biological processes including migration, survival and differentiation. Three-dimensional (3D culture has been proposed to provide a more physiological in vitro model of muscle growth and differentiation than routine 2D cultures. However, muscle cell adhesion and cell-matrix interplay of engineered muscle tissue remain to be determined. We have characterized cell-matrix interactions in 3D muscle culture and analyzed their consequences on cell differentiation. Human myoblasts were embedded in a fibrin matrix cast between two posts, cultured until confluence, and then induced to differentiate. Myoblasts in 3D aligned along the longitudinal axis of the gel. They displayed actin stress fibers evenly distributed around the nucleus and a cortical mesh of thin actin filaments. Adhesion sites in 3D were smaller in size than in rigid 2D culture but expression of adhesion site proteins, including α5 integrin and vinculin, was higher in 3D compared with 2D (p<0.05. Myoblasts and myotubes in 3D exhibited thicker and ellipsoid nuclei instead of the thin disk-like shape of the nuclei in 2D (p<0.001. Differentiation kinetics were faster in 3D as demonstrated by higher mRNA concentrations of α-actinin and myosin. More important, the elastic modulus of engineered muscle tissues increased significantly from 3.5 ± 0.8 to 7.4 ± 4.7 kPa during proliferation (p<0.05 and reached 12.2 ± 6.0 kPa during differentiation (p<0.05, thus attesting the increase of matrix stiffness during proliferation and differentiation of the myocytes. In conclusion, we reported modulations of the adhesion complexes, the actin cytoskeleton and nuclear shape in 3D compared with routine 2D muscle culture. These findings point to complex interactions between muscle cells and the surrounding matrix with dynamic regulation of the cell-matrix stiffness.

  10. Preparation of continuous alumina gel fibres by aqueous sol–gel ...

    Indian Academy of Sciences (India)

    Abstract. Continuous alumina gel fibres were prepared by sol–gel method. The spinning sol was prepared by mixing aluminum nitrate, lactic acid and polyvinylpyrrolidone with a mass ratio of 10:3:1·5. Thermogravimetry– differential scanning calorimetry (TG–DSC), Fourier transform infrared (FTIR) spectra, X-ray diffraction ...

  11. Laparoscopic intraperitoneal mesh fixation with fibrin sealant (Tisseel®) vs. titanium tacks: a randomised controlled experimental study in pigs

    DEFF Research Database (Denmark)

    Eriksen, J.R.; Bech, Jakob Ilsted; Linnemann, D.

    2008-01-01

    feasible in a pig model. There is still no evidence that fibrin-sealing alone is appropriate for intraperitoneal mesh fixation in hernia repair, but the technique might become an alternative or supplement to mechanical mesh fixation. Until then, further experimental research in animal hernia models...

  12. Management of radicular cysts using platelet-rich fibrin and bioactive glass: a report of two cases.

    Science.gov (United States)

    Zhao, Jiing-Huei; Tsai, Chung-Hung; Chang, Yu-Chao

    2014-07-01

    Platelet-rich fibrin (PRF) created by Choukroun's protocol concentrates most platelets and leukocytes from a blood harvest into a single autologous fibrin biomaterial. However, no current data is available concerning the use of PRF for the treatment of periapical lesions. Two cases of radicular cysts were reported using an interdisciplinary approach, including regular endodontic therapy followed by surgical management with PRF and bioactive glass. Two cases of radicular cysts presented as an incidental radiographic finding, appearing as an apical radiolucency with well-circumscribed sclerotic borders. After regular endodontic retreatment, cystic lining/granulation tissues were enucleated and the periradicular bony defect was grafted using PRF and bioactive glass. Then, PRF was applied to serve as a membrane over the grafted defects. Recall periapical radiographs of Case 1 and cone beam computer tomography of Case 2 showed satisfactory healing of the periapical pathosis. In Case 2, the bony defect appeared completely healed at 4 months surgical reentry and the new bone was clinically very dense and mature. The results of these case reports show that the combination of PRF and bioactive glass is an effective modality of regenerative treatment for radicular cysts. Copyright © 2012. Published by Elsevier B.V.

  13. Management of radicular cysts using platelet-rich fibrin and bioactive glass: A report of two cases

    Directory of Open Access Journals (Sweden)

    Jiing-Huei Zhao

    2014-07-01

    Full Text Available Platelet-rich fibrin (PRF created by Choukroun’s protocol concentrates most platelets and leukocytes from a blood harvest into a single autologous fibrin biomaterial. However, no current data is available concerning the use of PRF for the treatment of periapical lesions. Two cases of radicular cysts were reported using an interdisciplinary approach, including regular endodontic therapy followed by surgical management with PRF and bioactive glass. Two cases of radicular cysts presented as an incidental radiographic finding, appearing as an apical radiolucency with well-circumscribed sclerotic borders. After regular endodontic retreatment, cystic lining/granulation tissues were enucleated and the periradicular bony defect was grafted using PRF and bioactive glass. Then, PRF was applied to serve as a membrane over the grafted defects. Recall periapical radiographs of Case 1 and cone beam computer tomography of Case 2 showed satisfactory healing of the periapical pathosis. In Case 2, the bony defect appeared completely healed at 4 months surgical reentry and the new bone was clinically very dense and mature. The results of these case reports show that the combination of PRF and bioactive glass is an effective modality of regenerative treatment for radicular cysts.

  14. Sealing wells with gel

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, E C

    1967-10-01

    A new system is being used in Mexico to temporarily plug producing wells. The temporary seal is a gel with a catalyst. The use of this temporary plug allows gas-lift wells to be taken off production in order to carry out emergency repairs. The gel solidifies by the action of the catalyst to a high temperature (70 - 150/sup 0/C). By locating the bottom of the tubing at the top of the production interval, the gel material will go into the permeable formation, and immediately set. When the gel has solidified, it seals off the horizon that must not be stimulated, and leaves the others exposed to the acid action. When the treatment is finished, the gel, by action of the catalyst, is liquefied and removed from the formation, being produced with the oil.

  15. Gel-eletroforese no diagnóstico da varíola Gel-electrophoresis in the smallpox diagnosis

    Directory of Open Access Journals (Sweden)

    Julio A. Mesquita

    1972-01-01

    Full Text Available O emprego de gel-eletroforese no diagnóstico da varíola, demonstrou ser ao menos trinta vezes (30X mais sensível que o teste de agar-gel, nas condições descritas (tabela I. Doze (12 espécimes, cujos testes convencionais de inoculação em ovos embrionados e de agar-gel resultaram positivos, foram testados em suas diluições originais congeladas por mais de um ano, sendo seis deles revelados por gel-eletroforese enquanto nenhum o foi por agar-gel (tabela II. Trinta e três (33 amostras isoladas no laboratório, foram testadas com material colhido de membrana cório-alantóica da primeira inoculação para o diagnóstico, conservado em glicerina 50%, resultando 15 positivas em gel-eletroforese e apenas 3 em agar-gel (tabela II. Os últimos 60 espécimes recebidos para diagnóstico, através a Campanha de Erradicação da Varíola, também resultaram negativos em gel-eletroforese, que não mostrou falsos-positivos nas condições descritas.The test of gel-electrophoresis applied to the pox virus group showed to be at least thirth times (30X more sensitive than agar-gel test on the described conditions (Table I. Twelve specimens, which were positives form Smallpox in the conventional tests of egg inoculation and agar-gel difusion test, have been screened in their original dilutions frozen for more than 1 year and six of them were still detectable by gel-eletrophoresis, while by agar-gel test any of them was positive (Table II. Thirty three Smallpox isolates have been tested with material from first egg inoculation (chorioallantoic membranes which have been stored in glycerin 50%, at - 15ºC. Fifteen of them were still positive by gel-electrophoresis and only 3 by agar-gel (Table II. The last 60 specimens received for diagnosis from Smallpox Erradication Campaign (CEV, were negatives by both tests. The gel-electrophoresis, did not show false-positives on described conditions.

  16. Neutron detector based on lithiated sol-gel glass

    CERN Document Server

    Wallace, S; Miller, L F; Dai, S

    2002-01-01

    A neutron detector technology is demonstrated based on sup 6 Li/ sup 1 sup 0 B doped sol-gel glass. The detector is a sol-gel glass film coated silicon surface barrier detector (SBD). The ionized charged particles from (n, alpha) reactions in the sol-gel film enter the SBD and are counted. Data showing that gamma-ray pulse amplitudes interfere with identifying charged particles that exit the film layer with energies below the gamma-ray energy is presented. Experiments were performed showing the effect of sup 1 sup 3 sup 7 Cs and sup 6 sup 0 Co gamma rays on the SBD detector. The reaction product energies of the triton and alpha particles from sup 6 Li are significantly greater than the energies of the Compton electrons from high-energy gamma rays, allowing the measurement of neutrons in a high gamma background. The sol-gel radiation detection technology may be applicable to the characterization of transuranic waste, spent nuclear fuel and to the monitoring of stored plutonium.

  17. Time-dependent changes in extra-domain A-fibronectin concentration and relative amounts of fibronectin-fibrin complexes in plasma of patients with peripheral arterial disease after endovascular revascularisation.

    Science.gov (United States)

    Pupek, Małgorzata; Krzyżanowska-Gołąb, Dorota; Kotschy, Daniel; Witkiewicz, Wojciech; Kwiatkowska, Wiesława; Kotschy, Maria; Kątnik-Prastowska, Iwona

    2018-03-13

    Fibronectin (FN) may be involved in time- and stage-dependent and inter-related controlled processes of inflammation, coagulation, and wound healing accompanying peripheral arterial disease (PAD). In the present study, FN and FN-containing extra-domain A (EDA-FN), macromolecular FN-fibrin complexes, and FN monomer were analysed in the plasma of 142 PAD patients, including 37 patients with restenosis, for 37 months after revascularisation. FN concentration increased significantly in the plasma of PAD patients within 7 to 12 months after revascularisation, whereas the high concentration of EDA-FN was maintained up to 24 months, significantly higher in the group 7 to 12 months after revascularisation with recurrence of stenosis and lower in the PAD groups 1 to 3 months and 4 to 6 months after revascularisation with comorbid diabetes and ulceration, respectively. The relative amounts of FN-fibrin complexes up to 1600 kDa and FN monomer were significantly higher, within intervals of 4 to 24 months and 4 to 6 months after revascularisation, respectively. Moreover, the relative amounts of 750 to 1600 kDa FN-fibrin complexes within 13 to 24 months after revascularisation were higher in comparison with those in the group without restenosis. In conclusion, high levels of EDA-FN and FN-fibrin complexes could have potential diagnostic value in the management of PAD patients after revascularisation, predicting restenosis risk. © 2018 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  18. Instrumental texture profile analysis of gelatin gel extracted from grouper skin and commercial (bovine and porcine) gelatin gels.

    Science.gov (United States)

    Rahman, Mohammad Shafiur; Al-Mahrouqi, Abdullah Issa

    2009-01-01

    Mechanical compression was used to study the gelling characteristics of gelatin gels. Texture profile analysis (TPA) showed that the hardness of fish and mammalian gelatin increased significantly as the concentrations of gels increased. TPA attributes of 10% fish skin gel showed significant differences from those obtained from 20% and 30% gels. In bovine and porcine cases, such generic trends were not observed. Mechanical characteristics of 10% gels of gelatin from fish skin, determined from one cycle compression, were significantly lower than other sources of gelatin gels, while bovine and porcine gels did not show any significant differences. In the case of TPA, hardness of bovine gelatin gel was highest at 41 N for 10% gel, followed by porcine (30 N) then fish skin (5 N) gelatin gels. The gels prepared from different sources did not show any generic trends when all other mechanical attributes were considered.

  19. Effects of Platelet-Rich Plasma & Platelet-Rich Fibrin with and without Stromal Cell-Derived Factor-1 on Repairing Full-Thickness Cartilage Defects in Knees of Rabbits

    Directory of Open Access Journals (Sweden)

    Soghra Bahmanpour

    2016-11-01

    Full Text Available Background: The purpose of this study was to create biomaterial scaffolds like platelet-rich plasma (PRP and platelet-rich fibrin (PRF containing stromal cell-derived factor-1 (SDF1 as a chemokine to induce hyaline cartilage regeneration of rabbit knee in a full thickness defect. Methods: We created a full thickness defect in the trochlear groove of thirty-six bilateral knees of eighteen mature male rabbits. The knees were randomly divided into six groups (group I: untreated control, group II: PRP, group III: PRF, group IV: Gelatin+SDF1, group V: PRP+SDF1, and group VI: PRF+SDF1. After four weeks, the tissue specimens were evaluated by macroscopic examination and histological grading, immunofluorescent staining for collagen type II, and analyzed for cartilage marker genes by real-time PCR. The data were compared using statistical methods (SPSS 20, Kruskal-Wallis test, Bonferroni post hoc test and P<0.05. Results: Macroscopic evaluations revealed that international cartilage repair society (ICRS scores of the PRF+SDF1 group were higher than other groups. Microscopic analysis showed that the ICRS score of the PRP group was significantly lower than other groups. Immunofluorescent staining for collagen II demonstrated a remarkable distribution of type II collagen in the Gel+SDF1, PRP+SDF1 and PRF+SDF1 groups compared with other groups. Real-time PCR analysis revealed that mRNA expression of SOX9 and aggrecan were significantly greater in the PRF+SDF1, PRP+SDF1, Gel+SDF1 and PRF groups than the control group (P<0.05. Conclusion: Our results indicate that implantation of PRF scaffold containing SDF1 led to the greatest evaluation scores of full-thickness lesions in rabbits.

  20. Influence of Whitening Gel Application Protocol on Dental Color Change

    Directory of Open Access Journals (Sweden)

    Taciana Marco Ferraz Caneppele

    2015-01-01

    Full Text Available Objectives. To evaluate the influence of different whitening protocols on the efficacy of 35% hydrogen peroxide (HP tooth whitening and gel pH and concentration. Material and Methods. Eighty-four enamel/dentin discs from bovine incisors were used. The baseline color was measured with a spectrophotometer. Two sessions of in-office whitening with 35% HP were performed under different protocols: G1: 3 applications of HP (10 min each per session; G2: 1 application of 30 min per session; G3: 1 application of 40 min per session, with no gel replenishment within session for groups 2 and 3. HP titration and pH evaluation at baseline, after 10, 30, and 40 min were also performed. The final color was measured 24 h after the 1st and 2nd whitening sessions. Data were submitted to Repeated Measures ANOVA and Tukey’s test. Results. For color evaluation, no differences were observed among groups after two sessions. HP titration showed no drop on concentration after 10, 30, or 40 min. The pH was 5.54 at baseline and 5.41 after 40 min. Conclusion. Replenishment or extended application time of in-office whitening gel does not affect gel pH and concentration, a fact that supports the similar effectiveness of whitening observed among the tested protocols.