WorldWideScience

Sample records for fenestrated endovascular stent

  1. In-situ laser fenestration of endovascular stent-graft in abdominal aortic aneurysm repair (EVAR)

    Science.gov (United States)

    Micheletti, Filippo; Pini, Roberto; Piazza, Roberta; Ferrari, Vincenzo; Condino, Sara; Rossi, Francesca

    2017-02-01

    Endovascular abdominal aortic aneurysms repair (EVAR) involves the minimally invasive implantation of a stent-graft within the aorta to exclude the aneurysm from the circulation thus preventing its rupture. The feasibility of such operation is highly dependent on the aorta morphology and in general the presence of one/both renal arteries emerging from the aneurysm is the absolute limit for the implantation of a standard stent-graft. Consequently, classical intervention methods involve the implantation of a custom-made graft with fenestrations, leading to extremely complicated surgeries with high risks for the patient and high costs. Recent techniques introduced the use of standard grafts (i.e. without fenestrations) in association with mechanical in-situ fenestration, but this procedure is limited principally by the brittleness and low stability of the environment, in addition to the difficulty of controlling the guidance of the endovascular tools due to the temporarily block of the blood flow. In this work we propose an innovative EVAR strategy, which involves in-situ fenestration with a fiber guided laser tool, controlled via an electromagnetic navigation system. The fiber is sensorized to be tracked by means of the driving system and, using a 3D model of the patient anatomy, the surgeon can drive the fiber to the aneurysm, where the stent has been previously released, to realize the proper fenestration(s). The design and construction of the catheter laser tool will be presented, togheter with preliminary fenestration tests on graft-materials, including the effects due to the presence of blood and tissues.

  2. Multislice CT Angiography of Fenestrated Endovascular Stent Grafting for Treating Abdominal Aortic Aneurysms: a Pictorial Review of the 2D/3D Visualizations

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua [Curtin University, Perth (Australia); Mwipatayi, Bibombe P [Royal Perth Hospital, Perth (Australia); Allen, Yvonne B; Hartley, David E [Cook R and D, Perth (Australia); Lawrence-Brown, Michael M [Curtin University of Technology, Perth (Australia)

    2009-06-15

    Fenestrated endovascular repair of an abdominal aortic aneurysm has been developed to treat patients with a short or complicated aneurysm neck. Fenestration involves creating an opening in the graft fabric to accommodate the orifice of the vessel that is targeted for preservation. Fixation of the fenestration to the renal arteries and the other visceral arteries can be done by implanting bare or covered stents across the graft-artery ostia interfaces so that a portion of the stent protrudes into the aortic lumen. Accurate alignment of the targeted vessels in a longitudinal aspect is hard to achieve during stent deployment because rotation of the stent graft may take place during delivery from the sheath. Understanding the 3D relationship of the aortic branches and the fenestrated vessel stents following fenestration will aid endovascular specialists to evaluate how the stent graft is situated within the aorta after placement of fenestrations. The aim of this article is to provide the 2D and 3D imaging appearances of the fenestrated endovascular grafts that were implanted in a group of patients with abdominal aortic aneurysms, based on the multislice CT angiography. The potential applications of each visualization technique were explored and compared with the 2D axial images

  3. Superior mesenteric artery outcomes after fenestrated endovascular aortic aneurysm repair.

    Science.gov (United States)

    Lala, Salim; Knowles, Martyn; Timaran, David; Baig, Mirza Shadman; Valentine, James; Timaran, Carlos

    2016-09-01

    The Zenith (Cook Medical, Bloomington, Ind) fenestrated endovascular graft may be designed with single-wide scallops or large fenestrations to address the superior mesenteric artery (SMA). Misalignment of the SMA with an unstented scallop or a large fenestration is possible. This study assessed SMA outcomes after fenestrated endovascular aortic aneurysm repair (FEVAR). During an 18-month period, 47 FEVARs were performed at a single institution. For analysis, patients were grouped according to unstented (n = 23) vs stented (n = 24) SMA scallops/fenestrations. The Institutional Review Board approved this single-institution observational study. Because this was a retrospective review of the data, patient consent was unnecessary for the study. Technical success for FEVAR was 100%. The median follow-up period was 7.7 months (range, 1-16 months). Nine of 21 patients (43%) in the unstented group had some degree of misalignment of the SMA (range, 9%-71%). Among these, four patients (44%) developed complications: three SMA stenoses and one occlusion. The mean peak systolic velocity in patients with and without SMA misalignment was 317.8 cm/s vs 188.4 cm/s (P < .08), respectively. No misalignment occurred in the stented group, and only one of 19 patients (5%) developed an SMA stenosis that required angioplasty. Overall, patients with unstented SMAs had significantly more adverse events directly attributable to SMA misalignment than the stented group (44% vs 5%, respectively; P < .05). Misalignment of the SMA with the use of unstented unreinforced scallops or fenestrations occurs frequently. Routine stenting of single-wide and large fenestrations, when feasible, may be a safer option for patients undergoing FEVAR. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  4. Fenestrated endovascular aortic repair for juxtarenal abdominal aortic aneurysm

    Institute of Scientific and Technical Information of China (English)

    GUO Wei; ZHANG Hong-peng; LIU Xiao-ping; JIA Xin; XIONG Jiang; MA Xiao-hui

    2013-01-01

    Background Endovascular stent-graft with fenestration can improve proximal sealing in patients with juxtarenal abdominal aortic aneurysm (JAAA).The purpose of this study was to describe our primary experience and evaluate the safety and efficacy of fenestrated device for JAAA in high-risk patients.Methods Between March 2011 and May 2012,nine male patients (mean age,(79.6±8.6) years) with asymptomatic JAAAs underwent elective deployment of the Zenith fenestrated stent-grafts at a single institution.All patients were treated in the hybrid operating room under general anesthesia.Follow-up computed tomography angiography (CTA) was routinely performed before discharge,at 3,6,and 12 months and annually thereafter.Results Procedural success was achieved in all cases.Total sixteen small fenestrations,two large fenestrations and eight scallops were used.Intra-operative complications occurred in four patients,which included one proximal type Ⅰ endoleak,two type Ⅱ endoleaks,and one renal artery dissection.The mean hospital stay was (8.9±1.4) days,mean blood loss was (360.5±46.8) ml,and mean iodinated contrast volume was (230.6±58.3) ml.The mean follow-up time was (7.6±4.2) months.The visceral graft patency was 100% until now.One patient had an increase of serum creatinine of more than 30%,but did not require dialysis.No patients died,no stent fractured,and migration were diagnosed during the follow-up.Conclusions The early results of fenestrated device for high-risk patients with complex JAAAs are satisfactory.However,long-term fenestrated graft durability and branch vessel patency remain to be determined.

  5. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z. [Dept. of Imaging and Applied Physics, Curtin Univ. of Tech., Perth, WA (Australia); Allen, Y.; Fitzsimmons, B.; Hartely, D. [Cook R and D, WA (Australia); Lawrence-Brown, M. [Dept. of Public Health, Curtin Univ. of Tech., Perth, WA (Australia)

    2007-06-15

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  6. Fenestrated stent grafts for the treatment of complex aortic aneurysm disease: A mature treatment paradigm

    NARCIS (Netherlands)

    Georgiadis, Georgiadis; van Herwaarden, Joost A.; Antoniou, George A.; Giannoukas, Athanasios D.; Lazarides, Miltos K.; Moll, Frans L.

    2016-01-01

    The introduction of fenestrated stent grafts (SGs) to treat abdominal aortic aneurysms (AAAs) with short proximal necks began in 1999. Nowadays, the whole visceral aorta can be treated totally by endovascular means. The established use of fenestrated devices to treat complex AAAs as a first-line man

  7. New insights in (acute) endovascular abdominal aneurysm repair : when fenestrated devices fall short

    NARCIS (Netherlands)

    Pol, R. A.; Tielliu, I. F. J.; Zeebregts, C. J.

    2013-01-01

    The suitability for endovascular aneurysm repair (EVAR) is determined primarily by abdominal aortic aneurysm (AAA) anatomy. For patients unsuitable for standard EVAR, due to proximal neck anatomy, fenestrated aortic stent-grafting (FEVAR) is a viable alternative to open repair surgery. Initially FEV

  8. Custom Fenestration Templates for Endovascular Repair of Juxtarenal Aortic Aneurysms

    Science.gov (United States)

    Leotta, Daniel F.; Starnes, Benjamin W.

    2015-01-01

    Physician-modified endovascular grafts, with fenestrations added to accommodate major branch vessels, provide a means for endovascular treatment of abdominal aortic aneurysms that are adjacent to the renal arteries. Manual measurements of vessel origin locations from CT images, however, take time and can lead to errors in the positions of the fenestrations. To make the fenestration process faster and more accurate, we have developed a procedure to create custom templates that serve as patient-specific guides for graft fenestration. We use a 3D printer to create a clear rigid sleeve that replicates the patient’s aorta and includes holes placed precisely at the locations of the branch vessels. The sleeve is slipped over the graft, the locations of the openings are marked with a pen, and the fenestrations are created after removing the sleeve. Custom fenestration templates can potentially save procedural costs and make minimally-invasive aortic aneurysm repair available to more patients. PMID:25864045

  9. "Squid-capture" modified in situ stent-graft fenestration technique for aortic arch aneurysm repair.

    Science.gov (United States)

    Hongo, Norio; Miyamoto, Shinji; Shuto, Rieko; Wada, Tomoyuki; Kamei, Noritaka; Sato, Aiko; Matsumoto, Shunro; Kiyosue, Hiro; Mori, Hiromu

    2014-08-01

    An 83-year-old female was found to have an fusiform aneurysm in the aortic arch. She was deemed to be a high surgical risk; therefore, endovascular stent-graft placement followed by revascularization of the brachiocephalic trunk using in situ stent-graft fenestration was considered. However, the safe application of fenestration was deemed difficult due to the tortuosity of the brachiocephalic artery. The patient was successfully treated with the aid of the "squid-capture" technique, which consists of deployment of the stent-graft in a snare wire loop that was advanced from the brachiocephalic artery and fenestration of the stent-graft with the support of the loop. A follow-up exam revealed complete sealing of the aneurysm without any complications. The squid-capture technique allows for the safe and secure puncture of the graft.

  10. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua; Chaichana, Thanapong [Curtin University of Technology, Perth (Australia)

    2010-02-15

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.

  11. Transhepatic approach for extracardiac inferior cavopulmonary connection stent fenestration.

    LENUS (Irish Health Repository)

    Kenny, Damien

    2012-02-01

    We report on a 3-year-old male who underwent transcatheter stent fenestration of the inferior portion of an extracardiac total cavopulmonary connection in the setting of hypoplastic left heart syndrome. Transhepatic approach, following an unsuccessful attempt from the femoral vein facilitated delivery of a diabolo-shaped stent.

  12. Bare Metal Stenting for Endovascular Exclusion of Aortic Arch Thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Mahnken, Andreas H., E-mail: mahnken@med.uni-marburg.de [University Hospital Giessen and Marburg, Philipps University of Marburg, Department of Diagnostic Radiology (Germany); Hoffman, Andras; Autschbach, Ruediger; Damberg, Anneke L. M., E-mail: anneke.damberg@rwth-aachen.de [University Hospital RWTH Aachen, Department of Thoracic, Cardiac and Vascular Surgery (Germany)

    2013-08-01

    BackgroundAortic thrombi in the ascending aorta or aortic arch are rare but are associated with a relevant risk of major stroke or distal embolization. Although stent grafting is commonly used as a treatment option in the descending aorta, only a few case reports discuss stenting of the aortic arch for the treatment of a thrombus. The use of bare metal stents in this setting has not yet been described.MethodsWe report two cases of ascending and aortic arch thrombus that were treated by covering the thrombus with an uncovered stent. Both procedures were performed under local anesthesia via a femoral approach. A femoral cutdown was used in one case, and a total percutaneous insertion was possible in the second case.ResultsBoth procedures were successfully performed without any periprocedural complications. Postoperative recovery was uneventful. In both cases, no late complications or recurrent embolization occurred at midterm follow-up, and control CT angiography at 1 respectively 10 months revealed no stent migration, freely perfused supra-aortic branches, and no thrombus recurrence.ConclusionTreating symptomatic thrombi in the ascending aorta or aortic arch with a bare metal stent is feasible. This technique could constitute a minimally invasive alternative to a surgical intervention or complex endovascular therapy with fenestrated or branched stent grafts.

  13. Endovascular coil embolization for ruptured kissing aneurysms associated with A1 fenestration.

    Science.gov (United States)

    Mitsuhara, Takafumi; Sakamoto, Shigeyuki; Kiura, Yoshihiro; Kurisu, Kaoru

    2011-01-01

    Fenestration of intracranial arteries is a rare anomaly, and is frequently associated with cerebral aneurysms. In this paper, we report rare kissing aneurysms associated with A1 fenestration. A 71-year-old woman presented with subarachnoid hemorrhage. Diagnostic digital subtraction angiography revealed two saccular aneurysms at the proximal junction of a fenestration and posterior aspect of the fenestration that appeared to be 'kissing' each other. Emergent endovascular coil embolization was performed. Kissing aneurysms associated with fenestration of the horizontal segment in the anterior cerebral artery are rare, and have not been reported. During treatment of such specific types of aneurysms by endovascular treatment, three-dimensional rotational digital subtraction angiography was very useful for deciding the appropriate working angles.

  14. Endovascular treatment of penetrating ulcers of the paraceliac aorta using fenestrated endografts.

    Science.gov (United States)

    Gargiulo, Mauro; Gallitto, Enrico; Freyrie, Antonio; Stella, Andrea

    2014-04-01

    Penetrating atherosclerotic ulcers (PAUs) are usually focal aortic lesions found in patients with significant comorbidities. They are ideal targets for an endovascular approach if localized in the descending thoracic or infrarenal aorta, but when an origin in the visceral vessels is involved, a standard endovascular approach might not be feasible or effective. We report 2 cases of endovascular treatment of PAUs involving the paraceliac abdominal aorta, using a custom-made tube fenestrated endograft with 4 fenestrations for the abdominal visceral vessels (i.e., celiac-trunk, superior mesenteric artery, and renal arteries). There were no intra- or perioperative complications. At 1 year of follow-up, patients were asymptomatic and computed tomography angiography revealed total lesion exclusion and patency of the visceral vessels. The use of a fenestrated endograft is a safe and effective option to treat paraceliac PAUs.

  15. Robot-assisted fenestrated endovascular aneurysm repair (FEVAR) using the Magellan system.

    Science.gov (United States)

    Riga, Celia V; Bicknell, Colin D; Rolls, Alexander; Cheshire, Nicholas J; Hamady, Mohamad S

    2013-02-01

    A 67-year-old man underwent robot-assisted three-vessel fenestrated endovascular aneurysm repair (FEVAR) for a 7.3-cm juxtarenal aneurysm. The 6-F robotic catheter was manipulated from a remote workstation, away from the radiation source. Robotic cannulation of the left renal artery was achieved within 3 minutes. System setup time was 5 minutes. There were no postoperative complications. Computed tomography angiography performed at discharge and at 4-month follow-up confirmed target vessel patency with no evidence of an endoleak. Selective cannulation of target vessels during FEVAR using this novel technology is feasible. Endovascular robotics may have a role in simplifying complex endovascular tasks and potentially reducing radiation exposure to the operator.

  16. Mesenchymal stem cell seeding promotes reendothelialization of the endovascular stent.

    Science.gov (United States)

    Wu, Xue; Wang, Guixue; Tang, Chaojun; Zhang, Dechuan; Li, Zhenggong; Du, Dingyuan; Zhang, Zhengcai

    2011-09-01

    This study is designed to make a novel cell seeding stent and to evaluate reendothelialization and anti-restenosis after the stent implantation. In comparison with cell seeding stents utilized in previous studies, Mesenchymal stem cells (MSCs) have advantages on promoting of issue repair. Thus it was employed to improve the reendothelialization effects of endovascular stent in present work. MSCs were isolated by density gradient centrifugation and determined as CD29(+) CD44(+) CD34(-) cells by immunofluorescence and immunocytochemistry; gluten and polylysine coated stents were prepared by ultrasonic atomization spray, and MSCs seeded stents were made through rotation culture according to the optimized conditions that were determined in previous studies. The results from animal experiments, in which male New Zealand white rabbits were used, show that the reendothelialization of MSCs coated stents can be completed within one month; in comparison with 316L stainless steel stents (316L SS stents) and gluten and polylysine coated stents, the intimal hyperplasia and in-stent restenosis are significantly inhibited by MSCs coated stents. Endovascular stent seeded with MSCs promotes reendothelialization and inhibits the intimal hyperplasia and in-stent restenosis compared with the 316L SS stents and the gluten and polylysine coated stents.

  17. Experimental Study and Design of Balloon expandable Endovascular Stent Expansion

    Institute of Scientific and Technical Information of China (English)

    WANG Yue-xuan; YI Hong; NI Zhong-hua

    2005-01-01

    The application background and experimental research overview of medical endovascular stent are presented. Based on the analytical comparison of the current research achievements, the life cycle of medical endovascular stent is pointed out and the characteristics of stent expansion in the life cycle are emphasized on.The experimental scheme of in vitro stent expansion based on the machine vision technology in LabVIEW is presented. The selection and usage of the chosen component devices and design of measurement program for experiment are expatiated. A special drug-loading stent was expanded on the assembled platform of selected equipments and experimental results were analyzed. The experimental scheme presented in the paper provides powerful experimental support for the optimization of stent design and computer simulation of stent expansion by the finite element analysis.

  18. Endovascular stent graft repair of multiple tuberculous thoracoabdominal aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Jung; Won, Je Hwan [Dept. of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of)

    2014-05-15

    We describe a case of multiple tuberculous aneurysms of the descending thoracic aorta and abdominal aorta repaired with endovascular stent graft. The case was a 47-year-old man who presented with three saccular pseudoaneurysms of aortoiliac bifurcation at computed tomography (CT) scan. Despite of antimycobacterial treatment, these aneurysms grew rapidly and saccular pseudoaneurysm of the descending thoracic aorta was newly seen. A bifurcated stent graft was successfully implanted in the aortoiliac bifurcation. Subsequently, endovascular stent graft was placed well in the descending thoracic aorta. Fourteen months after the procedure, the patient was stable and serial CT images showed regression of aneurysms with ongoing antimycobacterial treatment. Therefore, endovascular stent graft repair with antimycobacterial therapy may be a treatment option in patients with multiple tuberculous aneurysms.

  19. Endovascular retrieval of a prematurely deployed covered stent

    Institute of Scientific and Technical Information of China (English)

    Jefferson; T; Miley; Gustavo; J; Rodriguez; Ramachandra; P; Tummala

    2015-01-01

    Several techniques have been reported to address different endovascular device failures. We report the case of a premature deployment of a covered balloon mounted stent during endovascular repair of a posttraumatic carotid-cavernous fistula(CCF). A 50-year-old male suffered a fall resulting in loss of consciousness and multiple facial fractures. Five weeks later, he developed decreased left visual acuity, proptosis, chemosis, limited eye movements and cranial/orbit bruit. Cerebral angiography demonstrated a direct left CCF and endovascular repair with a 5.0 mm × 19 mm covered stent was planned. Once in the lacerum segment, increased resistance was encountered and the stent was withdrawn resulting in premature deployment. A 3 mm × 9 mm balloon was advanced over an exchange length microwire and through the stent lumen. Once distal to the stent, the balloon was inflated and slowly pulled back in contact with the stent. All devices were successfully withdrawn as a unit. The use of a balloon to retrieve a prematurely deployed balloon mounted stent is a potential rescue option if leaving the stent in situ carries risks.

  20. Distal landing zone open fenestration facilitates endovascular elephant trunk completion and false lumen thrombosis.

    Science.gov (United States)

    Roselli, Eric E; Sepulveda, Edgardo; Pujara, Akshat C; Idrees, Jahanzaib; Nowicki, Edward

    2011-12-01

    Controversy surrounds the endovascular treatment of chronic dissection because of inconsistent remodeling of the aorta. The purpose of this study was to assess efficacy and safety of a novel technique for repairing aneurysmal change associated with chronic descending aortic dissection. From July 2007 to April 2011, 24 patients with descending aortic aneurysmal change, consequent to previously repaired ascending aortic dissection or medically treated descending dissection, underwent combined open first-stage elephant trunk (ET) insertion and fenestration of the descending aorta intimal flap. Second-stage ET endovascular completion was performed with the index operation in 4 patients and later in 20 patients (median, 62 days). Repair was elective in 14 patients and urgent in 10 patients. Concomitant procedures were aortic valve replacement in 3 patients and coronary revascularization in 3 patients, and 16 procedures were reoperations. Chart review and analysis of 3-dimensional computed tomography (CT) scans were performed. Imaging follow-up was complete in 89% of patients during a median of 18 months (interquartile range [IQR], 10 to 28 months). Technical success was achieved in all patients. Moderate reduction in aortic size occurred in most patients, with no retrograde false lumen flow. Late reintervention was required in 5 patients: endovascular for distal type I endoleak in 2 patients, type II endoleak in 1 patient, pseudoaneurysm of the abdominal aorta in 1 patient, and 1 open repair for aneurysm of the untreated distal segment in 1 patient. One patient died of pulmonary embolism on postoperative day 19 after 1-stage repair (4.0%) and 1 patient (4%) had a transient stroke, but there was no renal failure, respiratory failure, or permanent spinal cord injury. Median length of stay was 13 days (IQR, 8 to 16 days) after first-stage ET and 8 days (IQR, 5 to 12 days) after endovascular ET completion. One patient died during a mean of 23 ± 11 months of follow-up. Open

  1. Aneurisma de la aorta abdominal: Tratamiento endovascular con una endoprótesis fenestrada Abdominal aortic aneurysm: Endovascular treatment with fenestrated endoprothesis

    Directory of Open Access Journals (Sweden)

    Román Rostagno

    2008-12-01

    Full Text Available El tratamiento endovascular de los aneurismas de aorta abdominal es una alternativa a la cirugía abierta para pacientes de alto riesgo. Consiste en la exclusión del saco aneurismático mediante la interposición de una endoprótesis colocada por vía femoral. El tratamiento endovascular no puede ser utilizado en todos los pacientes. Una limitación frecuente la constituye el nacimiento de una arteria visceral desde el saco aneurismático. Para contrarrestar esta limitación recientemente se han desarrollado endoprótesis fenestradas que presentan orificios que se corresponden con el nacimiento de las arterias involucradas en el aneurisma evitando su oclusión, permitiendo de esta manera el tratamiento endovascular. En esta comunicación se presenta un caso de tratamiento endovascular de un aneurisma de aorta abdominal mediante la colocación de una endoprótesis fenestrada en un paciente cuya arteria renal izquierda nacía directamente del saco aneurismático.Endovascular treatment of the abdominal aortic aneurysm is consider an alternative to open surgery for high risk patients. Its goal is to exclude the aneurysm from the circulation by using an endoprothesis introduced from a femoral approach. Patients must be strictly selected to avoid possible complications. The most frequent limitation is related to anatomic contraindications such as visceral arteries involved in the aneurysm. Fenestrated endograft have been recently developed to allow endovascular treatment when anatomic features contraindicate classic endovascular procedures. Fenestrated endograft have holes that match with the origin of the visceral arteries maintaining its potency. In this paper we report the endovascular treatment of an abdominal aortic aneurysm by using a fenestrated endoprothesis in a patient whose left renal artery is originated from the aneurysm.

  2. Present and future of endovascular SFA treatment: stents, stent-grafts, drug coated balloons and drug coated stents.

    Science.gov (United States)

    Bosiers, M; Deloose, K; Verbist, J; Peeters, P

    2008-04-01

    The current evolution towards treating more complex femoropopliteal lesions as seen in the renewed TASC II recommendations clearly reflects the continuous evolutions in femoropopliteal stent design. Recent stent design improvements focus on decreasing stent fractures rates which can negatively impact patency rates. By rearranging strut alignment towards helical connecting bridges or full helical stent designs, stent designers have successfully improved the fracture resistance of their stents. The superior fracture resistance of the latest stent generation in combination with the production of long nitinol stents of up to 20 cm in length allow that more difficult and complex lesions can be treated endovascularly. The continuous perfection of nitinol stent platforms followed by the transfer of coronary technologies (e.g. active coatings) towards peripheral devices might broaden the indications for the minimal invasive strategy towards TransAtlantic Inter-Society Consensus (TASC) II C&D lesions.

  3. Endovascular Gene Delivery from a Stent Platform: Gene- Eluting Stents.

    Science.gov (United States)

    Fishbein, Ilia; Chorny, Michael; Adamo, Richard F; Forbes, Scott P; Corrales, Ricardo A; Alferiev, Ivan S; Levy, Robert J

    A synergistic impact of research in the fields of post-angioplasty restenosis, drug-eluting stents and vascular gene therapy over the past 15 years has shaped the concept of gene-eluting stents. Gene-eluting stents hold promise of overcoming some biological and technical problems inherent to drug-eluting stent technology. As the field of gene-eluting stents matures it becomes evident that all three main design modules of a gene-eluting stent: a therapeutic transgene, a vector and a delivery system are equally important for accomplishing sustained inhibition of neointimal formation in arteries treated with gene delivery stents. This review summarizes prior work on stent-based gene delivery and discusses the main optimization strategies required to move the field of gene-eluting stents to clinical translation.

  4. Infrarenal abdominal aortic aneurysm. Endovascular repair with stent grafts; Infrarenales Bauchaortenaneurysma. Endovaskulaere Stent-Graft-Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, M.; Voshage, G.; Landwehr, P. [Klinik fuer Diagnostische und Interventionelle Radiologie, Gefaesszentrum Hannover, Diakoniekrankenhaus Henriettenstiftung gGmbH, Hannover (Germany); Busch, T. [Klinik fuer Gefaesschirurgie, Gefaesszentrum Hannover, Diakoniekrankenhaus Henriettenstiftung gGmbH, Hannover (Germany)

    2008-09-15

    As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich als Alternative zur offenen chirurgischen Versorgung etabliert. Im Gegensatz zu Letzterer ist die Aneurysmatherapie mittels Stent-Grafts auch bei schwerkranken, nicht operationsfaehigen Patienten moeglich, wobei der Nutzen kontrovers diskutiert wird. Im Gegensatz zur klassischen transabdominellen Operation ist die Stent-Graft-Technik anatomischen Einschraenkungen unterworfen, die aber kuenftig aufgrund bereits abzusehender technischer Weiterentwicklungen eine geringere Rolle spielen werden. Die Diagnostik, die Entscheidung fuer eine endovaskulaere Therapie, die praeinterventionelle Planung und die Nachsorge erfordern den Einsatz bildgebender Verfahren, v. a. der Computer- und Magnetresonanztomographie sowie der Sonographie. Die fuer die endovaskulaere Aneurysmabehandlung relevanten Aspekte der Diagnostik werden dargestellt. Auf die Technik, die Materialien, die Ergebnisse und die Komplikationen der Stent-Graft-Behandlung wird ausfuehrlich eingegangen. (orig.)

  5. Endovascular treatment of intracranial aneurysms using coil embolization plus an Enterprise stent

    Institute of Scientific and Technical Information of China (English)

    XU Xiang; SHANG Xiao-ming; CUI Jian-zhong; WANG Da-yong

    2011-01-01

    Background Several difficulties can arise from wide-neck cerebral aneurysms when treated with endovascular embolization. We aimed to investigate the effect of endovascular treatment of intracranial aneurysms using coil embolization plus an Enterprise stent.Methods Forty patients were treated with coil embolization plus an Enterprise stent between December 2008 and June 2010.Results The mortality of patients was 0. All stents were successfully implanted without any surgery-related complication.Conclusion The Enterprise stent has some advantages to be selected.

  6. Transbrachial branch cannulation during Zenith fenestrated endovascular aortic aneurysm repair using a robotically guided body-floss technique

    Directory of Open Access Journals (Sweden)

    Sukgu M. Han, MD

    2016-09-01

    Full Text Available Caudal angulation and stenosis of the renal arteries pose significant challenges in branch cannulation during the standard fenestrated endovascular aortic aneurysm repair (FEVAR. We describe an alternative technique of branch cannulation during FEVAR in a patient with a 6.5-cm juxtarenal abdominal aortic aneurysm, renal artery stenosis, and bilateral caudally oriented renal arteries. A brachiofemoral or “body-floss” access was established by traversing the top scallop. The brachial sheath was deflected toward the target fenestration using a steerable robotic femoral sheath, enabling transbrachial cannulation of the downgoing target renal artery. Postoperatively, the patient was discharged without complications. Steerable sheath-guided body-floss technique may facilitate cannulation of severely downgoing branch vessels during FEVAR.

  7. Endovascular stent-graft management of thoracic aortic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Dake, Michael D. E-mail: mddake@stanford.edu

    2001-07-01

    The traditional standard therapy for descending thoracic aortic aneurysm (TAA) is open operative repair with graft replacement of the diseased aortic segment. Despite important advances in surgical techniques, anesthetic management, and post-operative care over the last 30 years, the mortality and morbidity of surgery remains considerable, especially in patients at high risk for thoracotomy because of coexisting severe cardiopulmonary abnormalities or other medical diseases. The advent of endovascular stent-graft technology provides an alternative to open surgery for selected patients with TAA. The initial experience suggests that stent-graft therapy potentially may reduce the operative risk, hospital stay and procedural expenses of TAA repair. These potential benefits are especially attractive for patients at high risk for open TAA repair. Current results of endovascular TAA therapy document operative mortalities of between 0 and 4%, aneurysm thrombosis in 90 and 100% of cases, and paraplegia as a complication in 0 and 1.6% of patients. The early success of stent-graft repair of TAA has fostered the application of these devices for the management of a wide variety of thoracic aortic pathologies, including acute and chronic dissection, intramural hematoma, penetrating ulcer, traumatic injuries, and other diseases. The results of prospective controlled trials that compare the outcomes of stent-graft therapy with those of surgical treatment in patients with specific types of aortic disease are anxiously awaited before recommendations regarding the general use of these new devices can be made with confidence.

  8. Modification of an endovascular stent graft for abdominal aortic aneurysm

    Science.gov (United States)

    Moloye, Olajompo Busola

    Endovascular surgery is currently used to treat abdominal aortic aneurysms (AAA). A stent graft is deployed to exclude blood flow from the aneurysm sac. It is an effective procedure used in preventing aneurysm rupture, with reduced patient morbidity and mortality compared to open surgical repair. Migration and leakage around the device ("endoleak") due to poor sealing of the stent graft to the aorta have raised concerns about the long-term durability of endovascular repair. A preliminary study of cell migration and proliferation is presented as a prelude to a more extensive in vivo testing. A method to enhance the biological seal between the stent graft and the aorta is proposed to eliminate this problem. This can be achieved by impregnating the stent graft with 50/50 poly (DL-lactide co glycolic acid) (PLGA) and growth factors such as basic fibroblast growth factor (bFGF) or connective tissue growth factor (CTGF), at the proximal and distal ends. It is hypothesized that as PLGA degrades it will release the growth factors that will promote proliferation and migration of aortic smooth muscle cells to the coated site, leading to a natural seal between the aorta and the stent graft. In addition, growth factor release should promote smooth muscle cell (SMC) contraction that will help keep the stent graft in place at the proximal and distal ends. It is shown that a statistically significant effect of increased cell proliferation and migration is observed for CTGF release. Less of an effect is noted for bFGF or just the PLGA. The effect is estimated to be large enough to be clinically significant in a future animal study. The long term goal of this study is to reduce migration encounter after graft deployment and to reduce secondary interventions of EVAR especially for older patients who are unfit for open surgical treatment.

  9. Balloon-expandable covered stent therapy of complex endovascular pathology.

    Science.gov (United States)

    Giles, Heath; Lesar, Christopher; Erdoes, Luke; Sprouse, Richard; Myers, Stuart

    2008-11-01

    The current study was designed to investigate our hypotheses that balloon-expandable covered stents display acceptable function over longitudinal follow-up in patients with complex vascular pathology and provide a suitable alternative for the treatment of recurrent in-stent restenosis. All stents were Atrium iCast, which is a balloon-mounted, polytetrafluoroethylene-covered stent with a 6F/7F delivery system. A retrospective review was performed of 49 patients with 66 stented lesions. Data were analyzed with life tables and t-tests. The most commonly treated vessels were the iliac (61%) and renal (24%) arteries. Indications for covered stent placement were unstable atheromatous lesions (50%), recurrent in-stent restenosis (24%), aneurysm (8%), aortic bifurcation reconstruction (7.5%), dissection (4.5%), endovascular aneurysm repair-related (4.5%), and stent fracture (1.5%). Patency was assessed by angiogram or duplex ultrasonography. The primary end point was patency and secondary end points were technical success and access-site complications. Mean follow-up was 13 months (range 1.5-25). The technical success rate was 97%. Unsuccessful outcomes were due to deployment error (n=1) and stent malpositioning (n=1). The cohort (n=64) 6- and 12-month primary patency rates were 96% and 84%, respectively. Twelve-month assisted primary patency was 98%. Iliac artery stents (n=38) had a primary patency of 97% at 6 months and 84% at 12 months with an assisted primary patency of 100% at 12 months. Renal artery stents (n=16) had a primary patency of 92% at 6 months and 72% at 12 months with an assisted primary patency of 92% at 6 and 12 months. Stents placed for recurrent in-stent restenosis (n=16) had a primary patency of 85%, assisted primary patency of 93%, and a 15% restenosis rate at 12 months. Specifically, stents placed for renal artery recurrent in-stent restenosis (n=10) had a primary patency of 73%, assisted primary patency of 82%, and a restenosis rate of 27%. The

  10. Open Surgical Repair After Endovascular Treatment with Endologix Stent Graft: A Case Report

    Directory of Open Access Journals (Sweden)

    Ižsa Coskun

    2016-01-01

    Full Text Available Endovascular treatment of abdominal aortic aneurysm repair is increasingly being used today. We report a 72-year-old male patient who underwent open surgical repair due to separation of IntuTrak Powerlink XL (Endologix endovascular stent graft four months after endovascular intervention for abdominal aortic aneurysm with 9.5 cm diameter.

  11. Treatment of Endovascular Coil and Stent Migration Using the Merci Retriever: Report of Three Cases

    Directory of Open Access Journals (Sweden)

    David K. Kung

    2012-01-01

    Full Text Available Background. Coil and stent migration is a potentially catastrophic complication in endovascular neurosurgery, which may lead to cerebral thromboembolism. Techniques for removing migrated coil and stent are not well established. Methods and Results. We present three cases in which coil or stent migration occurred during endovascular embolization of a cerebral aneurysm. The Merci Retrievers were used successfully in all cases to remove the displaced foreign bodies. Technical details are described. Conclusion. The Merci Retriever device can be utilized successfully for removal of migrated coils and stents in endovascular neurosurgery.

  12. Expandable bioresorbable endovascular stent. I. Fabrication and properties.

    Science.gov (United States)

    Su, Shih-Horng; Chao, Robert Y N; Landau, Charles L; Nelson, Kevin D; Timmons, Richard B; Meidell, Robert S; Eberhart, Robert C

    2003-06-01

    A bioresorbable, expandable poly(L-lactic acid) stent has been designed, based on a linear, continuous coil array principle, by which multiple furled lobes convert to a single lobe upon balloon expansion, without heating. Stent strength and compliance are sufficient to permit deployment by a conventional balloon angioplasty catheter. Several multiple lobe configurations were investigated, with expansion ratios ranging from 1.4 to 1.9 and expanded diameters ranging from 2.3 to 4.7 mm. Compression resistance of the expanded stent is dependent on fiber coil density and fiber ply. A range sufficient for endovascular service was obtained, with less than 4% elastic recoil in six day saline incubation studies. Surface plasma treatment with di(ethylene glycol) vinyl ether significantly reduced platelet adhesion in a 1 h porcine arteriovenous shunt model. Patency was maintained in one week implant studies in the porcine common femoral artery. However, a strong inflammatory response, and significant reduction of the vascular lumen were observed following two weeks implantation. The design principles and fabrication techniques for this bioresorbable stent are sufficiently versatile that a broad range of applications can be addressed. Much work remains to be done, including long-term evaluation of the inflammatory response, and of polymer degradation. The results of this study demonstrate the feasibility of expandable biodegradable stent design and deployment by conventional means.

  13. Endovascular stent-graft placement for treatment of type B dissections

    Institute of Scientific and Technical Information of China (English)

    俞飞成

    2006-01-01

    Objective To evaluate the safety and effectiveness of endovascular stent-graft placement for treatment of type B dissection. Methods From April 2002 to December 2005,180 patients with type B dissection underwent endovascular stent-graft placement. There were 158 men and 22 women with mean age of 50. 4±10. 9 years. All patients were diagnosed by computed tomography(CT) or magnetic resonance imaging (MRI) scans. Stent-graft

  14. Stent Graft-in-Stent Graft as a Rescue Technique for Endovascular Treatment of Giant Extracranial Internal Carotid Aneurysm

    Science.gov (United States)

    Jeha, Salim Abdon Haber

    2016-01-01

    Endovascular treatment of a giant extracranial internal carotid aneurysm by a stent graft implantation was unsuccessful due to a high flow leak directly through the stent graft's coating. The problem was solved deploying a second stent graft inside the previously implanted one resulting in complete exclusion of the aneurysmal sac and patent carotid lumen preservation. The review of the literature did not provide a case using this endovascular strategy. Follow-up for more than 12 months, using CT angiography, showed confirmed aneurysmal exclusion and carotid patency and no clinical complications have been detected. PMID:27752387

  15. Fenestrated vertebrobasilar junction aneurysm: diagnostic and therapeutic considerations.

    Science.gov (United States)

    Albanese, Erminia; Russo, Antonino; Ulm, Arthur J

    2009-03-01

    Vertebrobasilar junction (VBJ) aneurysms are uncommon and are often found in association with basilar artery (BA) fenestration. The complex anatomical environment of the VBJ, and the complicated geometry of the fenestration make clipping of these aneurysms difficult. Therefore, endovascular treatment of these aneurysms is now widely accepted. The authors describe the case of a 43-year-old woman with sickle cell anemia. She presented with subarachnoid hemorrhage. Digital subtraction angiography was performed and depicted multiple intracranial aneurysms. The patient had a left superior hypophysial artery aneurysm, a right superior cerebellar artery-posterior cerebral artery aneurysm, and a VBJ aneurysm associated with a fenestration of the BA. The VBJ aneurysm was not identified on the initial angiogram and was only revealed after 3D rotational angiography was performed. The 3D reconstruction was critical to the understanding of the complex geometry associated with the fenestrated BA. The VBJ was reconstructed using a combination endovascular technique. The dominant limb of the fenestration was stented and balloon-assisted coiling was performed, followed by sacrifice of the nondominant vertebral artery using coils and the embolic agent Onyx. Postoperative angiography demonstrated successful occlusion of the aneurysm with reconstruction of the VBJ. To the authors' knowledge, this is the first report of a fenestrated VBJ aneurysm treated with the combination of stenting, balloon remodeling, coiling, and vessel sacrifice. Three-dimensional angiography was critical in making the correct diagnosis of the source of the subarachnoid hemorrhage and with operative planning.

  16. Trends in use of the only Food and Drug Administration-approved commercially available fenestrated endovascular aneurysm repair device in the United States.

    Science.gov (United States)

    Simons, Jessica P; Shue, Bing; Flahive, Julie M; Aiello, Francesco A; Steppacher, Robert C; Eaton, Elizabeth A; Messina, Louis M; Schanzer, Andres

    2017-05-01

    Fenestrated endografts are customized, patient-specific, endovascular devices with potential to significantly reduce morbidity and mortality of short-neck infrarenal and juxtarenal abdominal aortic aneurysm repair. The Zenith fenestrated endovascular graft (ZFEN) for abdominal aortic aneurysms (Cook Medical, Bloomington, Ind), Food and Drug Administration-approved in 2012, remains the only fenestrated device available in the United States. This technology is among the most technically complex catheter-based procedures and, therefore, inherently associated with serious risk for device-related complications. We sought to define patterns of physician and hospital adoption of ZFEN. Deidentified datasets containing numbers of physicians trained, orders by physicians and hospitals, and designs (fenestration/scallop configuration) was provided for U.S. ZFEN devices ordered (April 2012-August 2015). We evaluated the number of physicians trained, the number of devices ordered, hospital characteristics, and fenestration/scallop design configurations. Cook Medical assembled the datasets but played no role in study design, analysis, or interpretation of data. Between April 2012 and August 2015, 553 physicians attended formal ZFEN training sessions, 388 (70%) of whom ordered a total of 2669 devices. An increase in orders per month (nine in June 2012 and 91 in August 2015, 911% growth; P 20 devices. For physicians contributing >6 months of data (n = 336), the average number of devices ordered per year was three (standard deviation, 4); 272 (81%) ordered ≤ 5 devices/year, 15 (4.5%) ordered 11-20 devices/year, and 3 (0.9%) ordered >20 devices/year. Of devices with design details available (2618 of 2669; 98%), most common designs were 2 small fenestrations/1 scallop (1443; 55%), 2 small fenestrations/1 large fenestration (568; 22%), 1 small fenestration/1 scallop (173, 6.6%), and 2 small fenestrations (169; 6.5%). The average number of target vessels incorporated in each

  17. Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents.

    Science.gov (United States)

    Bowen, Patrick K; Guillory, Roger J; Shearier, Emily R; Seitz, Jan-Marten; Drelich, Jaroslaw; Bocks, Martin; Zhao, Feng; Goldman, Jeremy

    2015-11-01

    Although corrosion resistant bare metal stents are considered generally effective, their permanent presence in a diseased artery is an increasingly recognized limitation due to the potential for long-term complications. We previously reported that metallic zinc exhibited an ideal biocorrosion rate within murine aortas, thus raising the possibility of zinc as a candidate base material for endovascular stenting applications. This study was undertaken to further assess the arterial biocompatibility of metallic zinc. Metallic zinc wires were punctured and advanced into the rat abdominal aorta lumen for up to 6.5months. This study demonstrated that metallic zinc did not provoke responses that often contribute to restenosis. Low cell densities and neointimal tissue thickness, along with tissue regeneration within the corroding implant, point to optimal biocompatibility of corroding zinc. Furthermore, the lack of progression in neointimal tissue thickness over 6.5months or the presence of smooth muscle cells near the zinc implant suggest that the products of zinc corrosion may suppress the activities of inflammatory and smooth muscle cells.

  18. Metallic Zinc Exhibits Optimal Biocompatibility for Bioabsorbable Endovascular Stents

    Science.gov (United States)

    Bowen, Patrick K.; Guillory, Roger J.; Shearier, Emily R.; Seitz, Jan-Marten; Drelich, Jaroslaw; Bocks, Martin; Zhao, Feng; Goldman, Jeremy

    2015-01-01

    Although corrosion resistant bare metal stents are considered generally effective, their permanent presence in a diseased artery is an increasingly recognized limitation due to the potential for long-term complications. We previously reported that metallic zinc exhibited an ideal biocorrosion rate within murine aortas, thus raising the possibility of zinc as a candidate base material for endovascular stenting applications. This study was undertaken to further assess the arterial biocompatibility of metallic zinc. Metallic zinc wires were punctured and advanced into the rat abdominal aorta lumen for up to 6.5 months. This study demonstrated that metallic zinc did not provoke responses that often contribute to restenosis. Low cell densities and neointimal tissue thickness, along with tissue regeneration within the corroding implant, point to optimal biocompatibility of corroding zinc. Furthermore, the lack of progression in neointimal tissue thickness over 6.5 months or the presence of smooth muscle cells near the zinc implant suggest that the products of zinc corrosion may suppress the activities of inflammatory and smooth muscle cells. PMID:26249616

  19. Telescoping Dual Covered Stent Graft Construct for Endovascular Treatment of a Giant Extracranial Carotid Artery Pseudoaneurysm.

    Science.gov (United States)

    Ding, Dale; Starke, Robert M; Moriarty, Maurice; Brew, Stefan

    2016-12-01

    Large pseudoaneurysms which compress the parent vessel are challenging lesions to successfully treat with endovascular therapy. We describe the endovascular treatment of a giant extracranial carotid artery (ECCA) pseudoaneurysm resulting in substantial mass effect on the common carotid artery (CCA) bifurcation using a telescoping dual covered stent graft construct. A 56-year-old male was diagnosed with an 8.5 cm × 13 cm pseudoaneurysm arising from the left CCA bifurcation, which was causing luminal narrowing of the CCA and proximal internal carotid artery (ICA). The patient underwent endovascular intervention, during which a balloon-expandable covered stent was deployed within a heparin-bonded covered stent, such that the overall construct spanned from the CCA to the lower cervical ICA. The employment of a telescoping dual covered stent technique can successfully treat appropriately selected patients with large or giant ECCA pseudoaneurysms, with the concomitant goals of excluding the pseudoaneurysm and restoring the luminal caliber of the parent artery.

  20. Chronic impedance spectroscopy of an endovascular stent-electrode array

    Science.gov (United States)

    Opie, Nicholas L.; John, Sam E.; Rind, Gil S.; Ronayne, Stephen M.; Grayden, David B.; Burkitt, Anthony N.; May, Clive N.; O'Brien, Terence J.; Oxley, Thomas J.

    2016-08-01

    Objective. Recently, we reported a minimally invasive stent-electrode array capable of recording neural signals from within a blood vessel. We now investigate the use of electrochemical impedance spectroscopy (EIS) measurements to infer changes occurring to the electrode-tissue interface from devices implanted in a cohort of sheep for up to 190 days. Approach. In a cohort of 15 sheep, endovascular stent-electrode arrays were implanted in the superior sagittal sinus overlying the motor cortex for up to 190 days. EIS was performed routinely to quantify viable electrodes for up to 91 days. An equivalent circuit model (ECM) was developed from the in vivo measurements to characterize the electrode-tissue interface changes occurring to the electrodes chronically implanted within a blood vessel. Post-mortem histological assessment of stent and electrode incorporation into the wall of the cortical vessels was compared to the electrical impedance measurements. Main results. EIS could be used to infer electrode viability and was consistent with x-ray analysis performed in vivo, and post-mortem evaluation. Viable electrodes exhibited consistent 1 kHz impedances across the 91 day measurement period, with the peak resistance frequency for the acquired data also stable over time. There was a significant change in 100 Hz phase angles, increasing from -67.8° ± 8.8° at day 0 to -43.8° ± 0.8° at day 91, which was observed to stabilize after eight days. ECM’s modeled to the data suggested this change was due to an increase in the capacitance of the electrode-tissue interface. This was supported by histological assessment with >85% of the implanted stent struts covered with neointima and incorporated into the blood vessel within two weeks. Conclusion. This work demonstrated that EIS could be used to determine the viability of electrode implanted chronically within a blood vessel. Impedance measurements alone were not observed to be a useful predictor of alterations occurring

  1. Fenestrated and branched endovascular techniques for thoraco-abdominal aneurysm repair

    NARCIS (Netherlands)

    Verhoeven, ELG; Zeebregts, CJ; Kapma, MR; Tielliu, IFJ; Prins, TR; Van Den Dungen, JJAM

    Since 1991, endovascular aortic aneurysm repair (EVAR) has been established as an alternative for open surgical repair of aortic aneurysms. one of the main limitations for EVAR is the need for a sufficient scaling zone below or above vital aortic side branches. Recently, efforts have been made to

  2. Fenestrated and branched endovascular techniques for thoraco-abdominal aneurysm repair

    NARCIS (Netherlands)

    Verhoeven, ELG; Zeebregts, CJ; Kapma, MR; Tielliu, IFJ; Prins, TR; Van Den Dungen, JJAM

    2005-01-01

    Since 1991, endovascular aortic aneurysm repair (EVAR) has been established as an alternative for open surgical repair of aortic aneurysms. one of the main limitations for EVAR is the need for a sufficient scaling zone below or above vital aortic side branches. Recently, efforts have been made to ov

  3. Transhepatic approach to create stent fenestration in the extracardiac Fontan conduit in a child with dextrocardia and interrupted inferior vena cava with azygos continuation.

    Science.gov (United States)

    Kobayashi, Daisuke; Turner, Daniel R; Forbes, Thomas J

    2013-04-01

    Plastic bronchitis is a rare life-threatening complication of Fontan operation. When medical treatment is ineffective in the setting of high systemic venous pressures, Fontan fenestration may be considered to decompress venous pressures and improve cardiac output by creation of the right-to-left shunting. However, transcatheter approach can be difficult in patients with complex venous anatomy. We report a 4-year-old girl born with hypoplastic left ventricle and heterotaxy syndrome, who developed plastic bronchitis following extracardiac Fontan procedure. Her venous anatomy was complex with dextrocardia and interrupted inferior vena cava with azygos continuation. Stent fenestration was successfully performed via transhepatic approach, which was selected based on the anatomical relationship (between extracardiac conduit, left atrium, and hepatic veins) delineated by pre-catheterization cardiac MRI. Simultaneous transesophageal echocardiography guided the intervention. Her plastic bronchitis improved significantly in 3 months but slowly progressed after the stent fenestration. At her 8-month follow-up, stent fenestration remains open and she is currently under heart transplantation evaluation due to persistent plastic bronchitis. Treatment of plastic bronchitis can be undertaken with Fontan fenestration, with pre-procedural MRI playing an essential role in patients with complex venous anatomy.

  4. Endovascular Treatment of Multiple HIV-related Aneurysms Using Multilayer Stents

    Energy Technology Data Exchange (ETDEWEB)

    Euringer, Wulf [University Hospital Freiburg, Department of Diagnostic Radiology (Germany); Suedkamp, Michael; Rylski, Bartosz [University Hospital Freiburg, Department of Cardiovascular Surgery (Germany); Blanke, Philipp, E-mail: philipp.blanke@uniklinik-freiburg.de [University Hospital Freiburg, Department of Diagnostic Radiology (Germany)

    2012-08-15

    Complex peripheral aneurysm anatomy with major artery branches in the immediate vicinity and mycotic aneurysm often impede endovascular management using covered stent grafts. The Cardiatis Multilayer Stent (Cardiatis, Isnes, Belgium) is a recently approved innovative stent system for peripheral aneurysm management. Its multilayer design aims at decreasing mean velocity and vorticity within the aneurysm sac to cause thrombus formation while maintaining patency of branching vessels due to laminar flow. We present a case of bilateral subclavian artery aneurysms and perivisceral aortic aneurysms in an AIDS patient successfully treated with the Cardiatis Multilayer Stent at 18 months' follow-up.

  5. Endovascular stents: a review of their use in peripheral arterial disease.

    Science.gov (United States)

    Kudagi, Vinod S; White, Christopher J

    2013-06-01

    Technological advances in the past decade have shifted revascularization strategies from traditional open surgical approaches toward lower-morbidity percutaneous endovascular treatments for patients with lower extremity peripheral arterial disease (PAD). The continuing advances in stent design, more than any other advances, have fueled the growth of catheter-based procedures by improving the safety, durability, and predictability of percutaneous revascularization. Although the 2007 TransAtlantic Inter-Society Consensus (TASC) guidelines recommend endovascular therapy for type A and B aortoiliac and femoropopliteal lesions, recent developments in stent technology and increased experience of interventionists have suggested that a strategy of endovascular therapy first is appropriate in experienced hands for TASC type D lesions. The role of endovascular interventions is also expanding in the treatment of limb-threatening ischemia.

  6. Multiple multilayer stents for thoracoabdominal aortic aneurysm: a possible new tool for aortic endovascular surgery.

    Science.gov (United States)

    Tolva, Valerio Stefano; Bianchi, Paolo Guy; Cireni, Lea Valeria; Lombardo, Alma; Keller, Guido Carlo; Parati, Gianfranco; Casana, Renato Maria

    2012-01-01

    Endovascular surgery data are confirming the paramount role of modern endovascular tools for a safe and sure exclusion of thoracoabdominal lesions. A 57-year-old female presented with severe comorbidity affected by a 58 mm thoracoabdominal aortic aneurysm (TAAA). After patient-informed consent and local Ethical Committee and Italian Public Health Ministry authorization, three multilayer stents were implanted in the thoracoabdominal aortic tract, obtaining at a 20-month computed tomography scan follow up, a complete exclusion of the TAAA, with normal patency of visceral vessels. Multilayer stents can be used in thoracoabdominal aortic aneurysm, with positive results.

  7. Evaluation of Exercise-Induced Hypertension Post Endovascular Stenting of Coarctation of Aorta

    Directory of Open Access Journals (Sweden)

    Akbar Shah Mohammadi

    2010-08-01

    Full Text Available Background: Coarctation of the aorta (COA is a defect that accounts for 5-8% of all congenital heart diseases. Balloon angioplasty as a treatment for COA is increasingly performed, with endovascular stents having been proposed as a means of improving the efficacy and safety of the procedure. The aim of this study was to evaluate the systolic blood pressure gradient at rest and during maximal exercise at follow-up in patients post endovascular stenting of COA.Methods: Thirteen patients (4 native and 9 re-coarctation cases of COA after surgery or balloon angioplasty with a mean age of 11.1 ± 4.7 years underwent endovascular stenting between November 2007 and December 2009 via standard techniques for native COA as an alternative to surgical repair. Doppler echocardiography was performed pre and post stenting. Resting and exercise assessment of blood pressure was performed at follow-up.Results: Post stent implantation, no angiographic major complications were evident. Systolic blood pressure gradient decreased from 42 ± 8.8 mm Hg before stent placement to 7 ± 10 mm Hg at follow-up (p value < 0.001. Peak Doppler pressure gradient decreased from 30 ± 14 mm Hg to 14 ± 10 mm Hg at follow-up (p value < 0.007. One case of exerciseinduced hypertension was seen in patients.Conclusion: Endovascular stenting for native COA in older children and post-surgical COA repair in patients with residual COA and re-coarctation is a reasonable alternative to surgical correction. During early follow-up, stenting effectively alleviates the aortic arch obstruction with normalization of the systemic blood pressure both at rest and during maximal exercise.

  8. Infection of endovascular abdominal aortic aneurysm stent graft after urosepsis: case report and review of the literature.

    Science.gov (United States)

    Veger, H T C; Hedeman Joosten, P Ph; Thoma, S R; Visser, M J T

    2013-02-01

    Infection of endovascular abdominal aneurysm stent grafts is an uncommon but known complication. Inoculation with bacteria of the endovascular abdominal aneurysm stent graft during the actual implantation, in the periprocedural hospitalization or later due to an aortoenteric fistula, has been described in the literature. We report a case of endovascular abdominal aortic aneurysm stent graft infection occurring 40 months after implantation in a patient doing well up to an episode of urosepsis. In conclusion, we postulate that poor intraluminal healing of stent grafts, as observed in several explant studies, may result in a higher susceptibility to episodes of bacteremia than prosthetic vascular grafts inserted during open repair. We therefore consider the administration of prophylactic antibiotics in patients with endovascular stent grafts during periods with a likelihood of bacteremia.

  9. Endovascular covered stent treatment for descending aorta pseudoaneurysm following coarctation of the aorta repair in an infant.

    Science.gov (United States)

    Takawira, Farirai F; Sinyangwe, Greenwood; Mooloo, Rene

    2010-12-01

    The development of a pseudoaneurysm is a rare complication following repair of a coarctation of the aorta. Surgical management of pseudoaneurysms is associated with high morbidity and mortality. We describe the successful endovascular deployment of a covered stent in a sick infant with a descending aorta pseudoaneurysm, following the repair of an aortic coarctation. We highlight the challenges we encountered. Endovascular repair is a safe palliative alternative to re-do open surgery in unstable infants with large pseudoaneurysms following aortic coarctation repair. The role of endovascular stents as the final definitive therapy will remain limited by the deployable, small-size stents in small, growing children.

  10. Emergency endovascular repair of iliac artery rupture caused by post-stenting angioplasty with an endograft

    Institute of Scientific and Technical Information of China (English)

    ZHOU Yu-bin; WU Dan-ming; XU Ke; WANG Cheng-gang; YI Wei; JIA Qi; SUN Yu-xin

    2007-01-01

    @@ Iliac artery rupture is a rare complication of poststenting angioplasty and can lead to massive lifethreatening haemorrhage. Conventional surgery can not repair the damaged vessel easily and may cause substantial blood loss and high operative morbidity and mortality. We report our experience with a selfexpanding covered endoprosthesis for endovascular repair of the rupture of an iliac artery caused by stenting angioplasty.

  11. Classification of gutter type in parallel stenting during endovascular aortic aneurysm repair

    NARCIS (Netherlands)

    Overeem, Simon P.; Boersen, Johannes T.; Schuurmann, Richte C L; Jebbink, Erik Groot; Slump, Cornelis H.; Reijnen, Michel M.P.J.; de Vries, Jean-Paul P.M.

    Objective: Gutters can be described as the loss of continuous apposition between the main body of the endograft, the chimney stent graft, and the aortic wall. Gutters have been associated with increased risk of type IA endoleaks and are considered to be the Achilles' heel of chimney endovascular

  12. Geometrical consequences of kissing stents and the Covered Endovascular Reconstruction of the Aortic Bifurcation configuration in an in vitro model for endovascular reconstruction of aortic bifurcation

    NARCIS (Netherlands)

    Groot Jebbink, E.; Grimme, F.A.; Goverde, P.C.; Oostayen, J.A.; Slump, C.H.; Reijnen, M.M.P.J.

    2015-01-01

    OBJECTIVE: Kissing stents (KS) are commonly used to treat aortoiliac occlusive disease, but patency results are often lower than those of isolated stents. The Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) technique was recently introduced to reconstruct the aortic bifurcation

  13. Geometrical consequences of kissing stents and the covered endovascular reconstruction of the aortic bifurcation configuration in an in vitro model for endovascular reconstruction of aortic bifurcation

    NARCIS (Netherlands)

    Groot Jebbink, Erik; Grimme, Frederike A.B.; Goverde, Peter C.J.M.; Oostayen, van Jacques A.; Slump, Cornelis H.; Reijnen, Michel M.P.J.

    2015-01-01

    Objective: Kissing stents (KS) are commonly used to treat aortoiliac occlusive disease, but patency results are often lower than those of isolated stents. The Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) technique was recently introduced to reconstruct the aortic bifurcation

  14. Endovascular stent graft treatment of acute thoracic aortic transections due to blunt force trauma.

    LENUS (Irish Health Repository)

    Bjurlin, Marc A

    2012-02-01

    Endovascular stent graft treatment of acute thoracic aortic transections is an encouraging minimally invasive alternative to open surgical repair. Between 2006 and 2008, 16 patients with acute thoracic aortic transections underwent evaluation at our institution. Seven patients who were treated with an endovascular stent graft were reviewed. The mean Glasgow Coma Score was 13.0, probability of survival was .89, and median injury severity score was 32. The mean number of intensive care unit days was 7.7, mean number of ventilator support days was 5.4, and hospital length of stay was 10 days. Mean blood loss was 285 mL, and operative time was 143 minutes. Overall mortality was 14%. Procedure complications were a bleeding arteriotomy site and an endoleak. Endovascular treatment of traumatic thoracic aortic transections appears to demonstrate superior results with respect to mortality, blood loss, operative time, paraplegia, and procedure-related complications when compared with open surgical repair literature.

  15. Effective Endovascular Stenting of Malignant Portal Vein Obstruction in Pancreatic Cancer

    Directory of Open Access Journals (Sweden)

    Christian M. Ellis

    2009-01-01

    Full Text Available We report herein the case of a patient successfully treated by transhepatic portal venous stent placement for malignant portal vein obstruction with associated gastric and small bowel varices and repeated gastrointestinal bleeding. CT angiography and portography showed severe portal vein obstruction from recurrent pancreatic cancer 15 months following pancreaticoduodenectomy with tumor encasement and dilated collateral veins throughout the gastric and proximal small bowel wall as the suspected cause of the GI bleeding. Successful transhepatic endovascular stent placement of the splenic vein at the portal vein confluence followed by balloon dilation was performed with immediate decompression of the gastric and small bowel varices and relief of GI hemorrhage in this patient until his death four months later. The treatment for patients with this dilemma can prove to be difficult, but as we have shown endovascular stenting of the portal system is an effective treatment option.

  16. Endovascular stent placement in the treatment of upper extremity central venous obstruction in hemodialysis patients

    Energy Technology Data Exchange (ETDEWEB)

    Aytekin, Cueneyt E-mail: cuneytaytekin@hotmail.com; Boyvat, Fatih; Yagmurdur, Mahmut Can; Moray, Goekhan; Haberal, Mehmet

    2004-01-01

    Objective: To evaluate the efficacy of stent placement for treating upper extremity central venous obstruction in chronic hemodialysis patients. Methods and Material: Between January 1999 and October 2001, we inserted metallic stents into the upper extremity central veins of 14 patients with shunt dysfunction and/or arm swelling. The indications for stent placement were stenosis or occlusion of the central vein in the upper extremity used for dialysis. Six of the individuals were diagnosed with subclavian vein stenosis, and 5 with brachiocephalic vein stenosis. Of the remaining 3 patients, 2 had subclavian vein occlusion, and 1 had left brachiocephalic vein occlusion. Results: All the stent placement procedures were technically successful, and there were no major complications. Follow-up ranged from 2 weeks to 29 months. The 1-, 3-, 6- and 12-month primary stent patency rates were 92.8, 85.7, 50 and 14.3%, respectively. Repeat interventions, including percutaneous transluminal angioplasty and additional stent placement, were required in 9 patients. The 3-, 6-, 12-month, and 2-year assisted primary stent patency rates were 100, 88.8, 55.5 and 33.3%, respectively. Conclusion: Endovascular stent placement is an effective alternative to surgery in patients with shunt dysfunction due to obstruction of an upper extremity central vein. Repeated interventions are usually required to prolong stent patency.

  17. Combined stent and coil in endovascular treatment of intracranial wide-necked and fusiform aneurysms

    Institute of Scientific and Technical Information of China (English)

    刘建民; 黄清海; 许奕; 洪波; 张珑; 张鑫

    2004-01-01

    Background Wide-necked and fusiform aneurysms are challenges for interventional neuroradiologists and neurosurgeons since they may involve entire vessels or be irregular in shape, making is possible for Guglielmi detachable coil to protrude into the parent arteries. This study was to evaluate the endovascular treatment of intracranial wide-necked and fusiform aneurysms by using a combination of stents and coils.Methods From October 2000 to July 2001, eighteen patients with intracranial wide-necked or fusiform aneurysms were treated with intraluminal stenting in combination with endosaccular coiling.Results Stent placement and coil packing were technically successful in all patients. There were no complications related to the procedure except for the migration of the stent in four cases. The aneurysms were embolized with the coils after precise stenting, and total occlusion was obtained in 13 cases, neck remnants in 3, and loose occlusion in 2. All the patients recovered well. Short-term follow-up angiograms suggested patency of the parent arteries without recanalization.Conclusions A combination of endovascular stenting and coil packing may be a favorable alternative for the treatment of intracranial aneurysms that are unsuitable for surgical clipping or coil embolization. Further study is necessary to assess the long-term outcome.

  18. Benefit of endovascular stenting for aortic coarctation on systemic hypertension in adults.

    Science.gov (United States)

    Hamid, Tahir; Motwani, Manish; Schneider, Heiko; Dua, Jaspal Singh; Hoschtitzky, Andreas; Clarke, Bernard; Mahadevan, Vaikom S

    2015-12-01

    Endovascular stenting is a recognised treatment strategy for aortic coarctation (CoA) in adults. We assessed systemic hypertension control and the need for antihypertensive therapy after CoA stenting in adults. Data were collected prospectively on 54 patients (36 men; mean age: 34 ± 16 years) who underwent endovascular stenting for CoA over a 7-year period. Five patients were excluded as they did not attend follow-up appointments. Patients underwent clinical examination, including right arm systolic blood pressure (SBP) and 24-hour ambulatory blood pressure monitoring at baseline, 6-12 weeks and 9-12 months. There was a significant fall in mean peak-to-peak systolic gradient (PG) across the CoA after stenting (26 ± 11 mmHg vs. 5 ± 4 mmHg; P25 mmHg before stenting); baseline SBP was significantly higher in severe versus non-severe patients (160 mmHg vs. 148 mmHg; P=0.02). The absolute reduction in PG after stenting was significantly higher in the severe group (31 ± 7 mmHg vs. 14 ± 5 mmHg; P<0.0001), but there was no significant difference in SBP between groups at 6-12 weeks (141 mmHg vs. 135 mmHg; P=0.21) or 9-12 months (139 mmHg vs. 139 mmHg; P=0.96). Endovascular stenting of CoA results in a significant reduction in SBP at 6-12 weeks, which is sustained at 9-12 months, with similar outcomes in severe and non-severe CoA groups. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  19. Local gene delivery via endovascular stents coated with dodecylated chitosan–plasmid DNA nanoparticles

    Directory of Open Access Journals (Sweden)

    Dunwan Zhu

    2010-12-01

    Full Text Available Dunwan Zhu1*, Xu Jin2*, Xigang Leng1, Hai Wang1, Junbo Bao1, Wenguang Liu3, Kangde Yao3, Cunxian Song11Tianjin Key Laboratory of Biomedical Materials, Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China; 2Department of Anesthesia and Pain Therapy, Capital Medical University Affiliated Beijing Tiantan Hospital, Beijing, China; 3Research Institute of Polymeric Materials, Tianjin University, Tianjin, China; *Both investigators contributed equally to this work and are senior authors.Abstract: Development of efficacious therapeutic strategies to prevent and inhibit the occurrences of restenosis after percutaneous transluminal coronary angioplasty is critical for the treatment of cardiovascular diseases. In this study, the feasibility and efficiency of stents coated with dodecylated chitosan–plasmid DNA nanoparticles (DCDNPs were evaluated as scaffolds for localized and prolonged delivery of reporter genes into the diseased blood vessel wall. Dodecylated chitosan–plasmid DNA complexes formed stable positive charged nanospheres with mean diameter of approximately 90–180 nm and zeta potential of +28 ± 3 mV. As prepared DCDNPs were spray-coated on stents, a thin layer of dense DCDNPs was successfully distributed onto the metal struts of the endovascular stents as demonstrated by scanning electron microscopy. The DCDNP stents were characterized for the release kinetics of plasmid DNA, and further evaluated for gene delivery and expression both in vitro and in vivo. In cell culture, DCDNP stents containing plasmid EGFP-C1 exhibited high level of GFP expression in cells grown on the stent surface and along the adjacent area. In animal studies, reporter gene activity was observed in the region of the artery in contact with the DCDNP stents, but not in adjacent arterial segments or distal organs. The DCDNP stent provides a very promising strategy for cardiovascular gene therapy

  20. Endovascular stent-graft placement and secondary intervention for abdominal aortic aneurysm in a patient who had a previously inserted iliac stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Yong Sun; Cho, Soon Gu; Hong, Kee Chun [Inha University College of Medicine, Incheon (Korea, Republic of)

    2007-04-15

    Endovascular repair of abdominal aortic aneurysm is associated with low morbidity and mortality rates when compared to open surgery, and this can be used in patients who are at a high risk for open surgical repair. Also, secondary intervention is an important for achieving intermediate and long term success of endovascular repair of abdominal aortic aneurysm as this can resolve complications. We report here on endovascular stent-graft placement and a secondary interventional procedure in the abdominal aortic aneurysm of a patient who had a previously inserted iliac stent.

  1. Telescoping dual covered stent graft construct for endovascular treatment of a giant extracranial carotid artery pseudoaneurysm

    Directory of Open Access Journals (Sweden)

    Dale Ding

    2016-01-01

    Full Text Available Large pseudoaneurysms which compress the parent vessel are challenging lesions to successfully treat with endovascular therapy. We describe the endovascular treatment of a giant extracranial carotid artery (ECCA pseudoaneurysm resulting in substantial mass effect on the common carotid artery (CCA bifurcation using a telescoping dual covered stent graft construct. A 56-year-old male was diagnosed with an 8.5 cm × 13 cm pseudoaneurysm arising from the left CCA bifurcation, which was causing luminal narrowing of the CCA and proximal internal carotid artery (ICA. The patient underwent endovascular intervention, during which a balloon-expandable covered stent was deployed within a heparin-bonded covered stent, such that the overall construct spanned from the CCA to the lower cervical ICA. The employment of a telescoping dual covered stent technique can successfully treat appropriately selected patients with large or giant ECCA pseudoaneurysms, with the concomitant goals of excluding the pseudoaneurysm and restoring the luminal caliber of the parent artery.

  2. Clinical and angiographic results with the NIR stent: First International NIR Endovascular Stent Study (FINESS-II).

    Science.gov (United States)

    Rutsch, Wolfgang; Kiemeneij, Ferdinand; Colombo, Antonio; Macaya, Carlos; Guermonprez, Jean-Leon; Grip, Lars; Hamburger, Jaap; Umans, Victor; Gotsman, Mervyn; Almagor, Yaron; Morice, Marie-Claude; Garcia, Eulogio; Chevalier, Bernard; Erbel, Raimund; Cobaugh, Michael; Morel, Marie-Angèle; Serruys, Patrick W

    2000-09-01

    BACKGROUND: Although safety and efficacy of the NIR trade mark stent have been reported, the long-term angiographic and clinical outcomes have yet to be investigated. The FINESS-II study (First International NIR Endovascular Stent Study) was designed to assess the procedural safety of single 9 and 16 mm NIR stent implantation, the six-month restenosis rate and finally the six- and 12-month clinical outcome of patients treated with this novel coronary stent. METHODS: Patients with angina and a single de novo lesion in a native coronary artery of >3 and 50% diameter stenosis criterion at six month follow-up was 19% (26/136). At 12 months, the event-free survival rate was 83% (two deaths, one Q-wave and three non-Q-wave myocardial infarctions, four bypass surgery and 17 target lesion revascularizations), while 87% of the patients were free of angina pectoris. CONCLUSION: the outcome of the FINESS-II trial is comparable to those observed in previous stent trials (Benestent II), indicating that the coronary NIR stent is safe and effective as a primary device for the treatment of native coronary artery lesions in patients with (un)stable angina pectoris.

  3. Endovascular stent graft for treatment of complicated spontaneous dissection of celiac artery: Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Diagnostic Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Hwan [Dept. of Diagnostic Radiology, Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2013-06-15

    We report 2 cases of complicated spontaneous dissection of the celiac artery, which were successfully treated by a stent graft. The first patient was a 47-year-old man who presented with acute abdominal pain. CT scan showed ruptured saccular aneurysm with surrounding retroperitoneal hematoma. The second patient was a 57-year-old man with progressive dissecting aneurysm. Endovascular stent graft was placed in the celiac trunk to control bleeding, and to prevent rupture in each patient. Follow-up CT scans showed complete obliteration of a dissecting aneurysm.

  4. Unusual perigraft abscess formation associated with stent graft infection after endovascular aortic repair of abdominal aortic aneurysm: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyo Jin; Kim, Song Soo; Ahn, Moon Sang; Lee, Jae Hwan; Shin, Byung Seok; KIm, Jin Hwan [Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon (Korea, Republic of)

    2014-03-15

    Although a stent graft infection after endovascular aortic repair (EVAR) of abdominal aortic aneurysm (AAA) is a rare complication, it carries a high mortality and morbidity rate. We report a rare case of stent graft infection that led to an unusual perigraft abscess formation without any associated aortoenteric fistula two years after the EVAR of AAA.

  5. Thoracic stent grafts with a distal fenestration for the celiac axis

    NARCIS (Netherlands)

    Tielliu, IFJ; Verhoeven, ELG; Zeebregts, CJ; Prins, TR; van den Dungen, JJAM

    2005-01-01

    Descending thoracic aneurysms can be treated with a stent graft provided that there is sufficient proximal and distal aortic neck length above the celiac axis. One of the options for the treatment of thoracic aneurysms with a too short distal neck is described in this report. For this purpose, a ste

  6. Successful endovascular treatment of a hemodialysis graft pseudoaneurysm by covered stent and direct percutaneous thrombin injection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2011-07-25

    Vascular access for hemodialysis remains a challenge for nephrologists, vascular surgeons, and interventional radiologists alike. Arteriovenous fistula and synthetic grafts remain the access of choice for long-term hemodialysis; however, they are subject to complications from infection and repeated needle cannulation. Pseudoaneurysms are an increasingly recognized adverse event. At present, there are many minimally invasive methods to repair these wall defects. We present a graft pseudoaneurysm, which required a combination of endovascular stent graft placement and percutaneous thrombin injection for successful occlusion.

  7. Open Versus Endovascular Stent Graft Repair of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Firwana, Belal; Ferwana, Mazen; Hasan, Rim;

    2014-01-01

    We performed an analysis to assess the need for conducting additional randomized controlled trials (RCTs) comparing open and endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA). Trial sequential analysis (TSA) is a statistical methodology that can calculate the required inform...

  8. Blister-like aneurysms of the supraclinoid internal carotid artery: challenging endovascular treatment with stent-assisted coiling.

    Science.gov (United States)

    Ahn, Jung Yong; Cho, Jun Hyung; Jung, Jin Young; Lee, Byung Hee; Yoon, Pyeong Ho

    2008-09-01

    ''Blister-like'' aneurysms of the supraclinoid segment of the internal carotid artery are usually small and have fragile walls, necessitating special care to prevent rebleeding. These lesions are considered high-risk aneurysms because of the technical difficulties associated with their surgical and endovascular treatment. In this report, we describe the use of stent-assisted, repeated coil embolization in the treatment of a ruptured blister-like aneurysm that experienced rapid growth. Stent-assisted coil embolization is an alternative, but sometimes hazardous, treatment for select blister-like aneurysms. Careful serial follow-up angiography will provide documentation as to the long-term stability of the endovascularly treated blister-like aneurysm described here, but early results are encouraging. Alternatively, placement of telescoped stents or graft-stent devices offers promise for future endovascular therapy.

  9. Endovascular repair of ruptured aneurysm arising from fenestration of the horizontal segment of the anterior cerebral artery: case report.

    Science.gov (United States)

    Yoshida, Masahiro; Ezura, Masayuki; Sasaki, Kazuto; Chonan, Masashi; Mino, Masaki

    2012-01-01

    A 50-year-old man presented with an aneurysm arising from a fenestration of horizontal portion (A(1)) of the anterior cerebral artery manifesting as subarachnoid hemorrhage. Coil embolization was conducted and the aneurysm was occluded easily. Most reported cases of these types of aneurysms underwent direct surgery. Aneurysm arising from the A(1) fenestration is rare, but the present case shows that coil embolization can be an effective treatment modality. Three-dimensional rotational angiography and aneurysmography were helpful to characterize this complicated vascular structure.

  10. Endovascular stent-graft treatment of thoracic aortic syndromes: A 7-year experience

    Energy Technology Data Exchange (ETDEWEB)

    Dialetto, Giovanni [Department of Cardiothoracic and Respiratory Sciences, Second University of Naples, V. Monaldi Hospital, Naples (Italy); Reginelli, Alfonso; Cerrato, Marcella [Department of Radiology, Second University of Naples, Naples (Italy); Rossi, Giovanni [Department of Radiology, Monaldi Hospital, Naples (Italy); Covino, Franco Enrico; Manduca, Sabrina [Department of Cardiothoracic and Respiratory Sciences, Second University of Naples, V. Monaldi Hospital, Naples (Italy); Lassandro, Francesco [Department of Radiology, Monaldi Hospital, Naples (Italy)], E-mail: f.lassandro@tiscali.it

    2007-10-15

    Thoracic aortic diseases (TAD) are relatively frequent conditions associated with high mortality. Recently, several reports have demonstrated the safety and efficacy of endovascular stent-graft (EVG) placement for TAD as an alternative to open surgery. We report our experience in management of thoracic aortic syndrome on 56 consecutive patients with TAD that underwent endovascular stent-graft repair. MDCT angiography was used in all patients to provide preprocedure evaluation and measurements. In particular it is necessary to evaluate the proximal and distal landing zones of the stent-graft. All EVGs in our series were placed successfully. Conversion to open surgery was never required. Six patients (10.7%) died early after the stent-graft deployment. During follow-up four more patients died. The endoleak rate was 16.7% (no. 10 pt). We did not observe any case of paraplegia. The present study shows the efficacy of EVG in the long-term follow-up, with an overall survival of 82.1%, which is comparable to that reported in recent studies. In conclusion this technique is emerging as an alternative approach in the treatment of TAD because this approach offers a less invasive therapeutic option to standard surgical techniques, even in patients who have associated diseases that make them poor surgical candidates.

  11. Endovascular treatment of abdominal aortic aneurysms--6 years of experience with Ella stent-graft system

    Energy Technology Data Exchange (ETDEWEB)

    Koecher, Martin E-mail: martin.kocher@seznam.cz; Utikal, Petr; Koutna, Jirina; Bachleda, Petr; Buriankova, Eva; Herman, Miroslav; Bucil, Jiri; Benysek, Vladimir; Cerna, Marie; Kojecky, Zdenek

    2004-08-01

    Purpose: Evaluation of 6-year results of abdominal aortic aneurysm (AAA) treatment by Ella stent-grafts with regard to safety and effectivity in relation to morphology of the aneurysm. Methods: From a group of 172 patients with AAA, in whom elective endovascular treatment was considered, 120 of them (69.8%) were found to be suitable for this type of therapy. The bifurcated type of stent-graft was implanted in 97 patients, uniiliacal type in 19 patients and only four patients were found to be suitable for tubular type of stent-graft. Additional necessary procedures (internal iliac artery occlusion or contralateral common iliac artery occlusion in a group of patients with uniiliacal type of stent-graft) were performed surgically during the stent-graft implantation. CT and US controls were performed at 3, 6 and 12 months after implantation, later every 12 months. Results: Primary technical success was achieved in 109 of the 120 patients (91%). Primary endoleak was recorded in 11 patients (primary endoleak type Ia in seven patients, type Ib in three patients and type IIIa in one patient). Assisted technical success after reintervention or spontaneous seal was 98.3%. Surgical conversion was indicated in two patients (1.7%). Perioperative mortality rate was 3.3%. Total average follow-up period was 20.7 months (range from 2 to 60 months). In nine patients (7.5%) secondary endoleak type II was found at control CT or US, in three patients partial thrombosis of the stent-graft was found. There was no aneurysm rupture during follow-up. Conclusion: Treatment of AAA with Ella stent-graft system is effective and safe. Bifurcated stent-graft is the most frequently used type. Uniiliacal type of stent-graft is used by us only in cases of complicated morphology.

  12. Long-term Results of Endovascular Stent Graft Placement of Ureteroarterial Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Takuya, E-mail: okabone@gmail.com; Yamaguchi, Masato, E-mail: masato03310402@yahoo.co.jp [Kobe University Hospital, Department of Radiology (Japan); Muradi, Akhmadu, E-mail: muradiakhmadu@gmail.com; Nomura, Yoshikatsu, E-mail: y_katsu1027@yahoo.co.jp [Kobe University Hospital, Center for Endovascular Therapy (Japan); Uotani, Kensuke, E-mail: uotani@tenriyorozu.jp [Tenri Hospital, Department of Radiology (Japan); Idoguchi, Koji, E-mail: idoguchi@ares.eonet.ne.jp [Kobe University Hospital, Center for Endovascular Therapy (Japan); Miyamoto, Naokazu, E-mail: naoka_zu@yahoo.co.jp; Kawasaki, Ryota, E-mail: kawaryo1999@yahoo.co.jp [Hyogo Brain and Heart Center at Himeji, Department of Radiology (Japan); Taniguchi, Takanori, E-mail: tan9523929@yahoo.co.jp [Tenri Hospital, Department of Radiology (Japan); Okita, Yutaka, E-mail: yokita@med.kobe-u.ac.jp [Kobe University Hospital, Department of Cardiovascular Surgery (Japan); Sugimoto, Koji, E-mail: kojirad@med.kobe-u.ac.jp [Kobe University Hospital, Department of Radiology (Japan)

    2013-08-01

    PurposeTo evaluate the safety, efficacy, and long-term results of endovascular stent graft placement for ureteroarterial fistula (UAF).MethodsWe retrospectively analyzed stent graft placement for UAF performed at our institution from 2004 to 2012. Fistula location was assessed by contrast-enhanced computed tomography (CT) and angiography, and freedom from hematuria recurrence and mortality rates were estimated.ResultsStent graft placement for 11 UAFs was performed (4 men, mean age 72.8 {+-} 11.6 years). Some risk factors were present, including long-term ureteral stenting in 10 (91 %), pelvic surgery in 8 (73 %), and pelvic radiation in 5 (45 %). Contrast-enhanced CT and/or angiography revealed fistula or encasement of the artery in 6 cases (55 %). In the remaining 5 (45 %), angiography revealed no abnormality, and the suspected fistula site was at the crossing area between urinary tract and artery. All procedures were successful. However, one patient died of urosepsis 37 days after the procedure. At a mean follow-up of 548 (range 35-1,386) days, 4 patients (36 %) had recurrent hematuria, and two of them underwent additional treatment with secondary stent graft placement and surgical reconstruction. The hematuria recurrence-free rates at 1 and 2 years were 76.2 and 40.6 %, respectively. The freedom from UAF-related and overall mortality rates at 2 years were 85.7 and 54.9 %, respectively.ConclusionEndovascular stent graft placement for UAF is a safe and effective method to manage acute events. However, the hematuria recurrence rate remains high. A further study of long-term results in larger number of patients is necessary.

  13. Endovascular treatment of peripheral arterial injury with covered stents: an experimental study in pigs

    Directory of Open Access Journals (Sweden)

    Sergio Belczak

    2011-01-01

    Full Text Available OBJECTIVE: To evaluate the feasibility of using endovascular repair to treat penetrating arterial injuries with covered stents. Feasibility was examined according to the circumferential extent of the injury. INTRODUCTION: Surgical trauma often increases the risk of major morbidity and mortality associated with vascular injury, and endovascular repair has many advantages in such situations. METHODS: Twenty white male domestic pigs weighing 28-38 kg with controlled vascular injuries were divided into four equal groups according to the circumferential extent of their vascular lesion (i.e., no lesion, lesion 50%, and complete lesion. The left common carotid artery was dissected with proximal and distal control, and this procedure was followed by controlled sectioning of the arterial wall. Local manual compression was applied for 10 min and was followed by endovascular repair with the placement of a 5x50 mm VIABHAN TM covered stent using the femoral approach. We also monitored additional variables, such as the duration of the procedures (the mean was 56.3 ± 19.1 min, ultrasound parameters (e.g., maximum arterial diameter, peak systolic and diastolic velocity, and resistance index, arteriography findings, and fluctuations in vital signs (e.g., cardiac output, arterial pressure, and central venous pressure. RESULTS: The experimental procedure was found to be feasible and reproducible. Repairs were successful in all animals in the control (no lesion and 50% group and in one pig in the complete lesion group. DISCUSSION: The endovascular repair of an arterial injury is possible, but success depends on the circumferential extent of the arterial lesion. The present experimental model, which involved endovascular techniques, highlighted important factors that must be considered in future studies involving similar animals and materials.

  14. A new stent with streamlined cross-section can suppress monocyte cell adhesion in the flow disturbance zones of the endovascular stent.

    Science.gov (United States)

    Chen, Zengsheng; Zhan, Fan; Ding, Jun; Zhang, Xiwen; Deng, Xiaoyan

    2016-01-01

    We proposed a new stent with streamlined cross-sectional wires, which is different from the clinical coronary stents with square or round cross-sections. We believe the new stent might have better hemodynamic performance than the clinical metal stents. To test the hypothesis, we designed an experimental study to compare the performance of the new stent with the clinical stents in terms of monocyte (U-937 cells) adhesion. The results showed that when compared with the clinical stents, the adhesion of U-937 cells were much less in the new stent. The results also showed that, when Reynolds number increased from 180 (the rest condition for the coronary arteries) to 360 (the strenuous exercise condition for the coronary arteries), the flow disturbance zones in the clinical stents became larger, while they became smaller with the new stent. The present experimental study therefore suggests that the optimization of the cross-sectional shape of stent wires ought to be taken into consideration in the design of endovascular stents.

  15. Endovascular stents for coarctation of aorta in children and adolescents: early and intermediate- term results

    Directory of Open Access Journals (Sweden)

    Mortezaeian Langroodi H

    2010-09-01

    Full Text Available "nBackground: Coarctation of aorta is narrowing of proximal descending aorta. Interventional procedures such as balloon angioplasty & stent implantation has been progressively in use as alternatives for surgery in increasing number of children with diagnosis of coarctation of aorta. The aim of this study was to evaluate the use of endovascular stent in children with coarctation of aorta."n "nMethods: We evaluated effectiveness and safety of stenting in all patients younger than 18 years old with coarctation and re-coarctation of aorta which treated by stenting between years 2004-9 at rajaei - heart centre in Tehran, Iran. "n "nResults: we studied 53 patients younger than 18 years old with a follow up of six months. Totally 54 stents were implanted. Mean (±SD age of the patients was 11.6±4.2yrs. Seventeen cases (32% were younger than 10 years old, and 36 cases (68% were 10 years and older. Mean (±SD weight was 39.24±18kg. 16 cases weighting less than 25kg. Peak systolic pressure gradient (SPG decreased from 46.26±17.07 to 1.03±0.19mmHg after procedure (p<0.001. There was no significant difference (p<0.001 in the gradient before and after stenting in the patients with native coarctation (Vs re-coarctation cases, less than 25 kg and under 10 years old groups. Complications developed in 44% of cases while dominantly were minor except in two cases re-dilatation of stent was not needed during six month of follow-up of the patients."n "nConclusions: Stenting of coarctation of aorta can decrease complications and can be used safely in children weighing bellow 25kg and in children below 10yrs old.

  16. Covered stents for endovascular repair of iatrogenic injuries of iliac and femoral arteries

    Energy Technology Data Exchange (ETDEWEB)

    Kufner, Sebastian, E-mail: kufners@dhm.mhn.de [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Cassese, Salvatore; Groha, Philipp; Byrne, Robert A. [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Schunkert, Heribert; Kastrati, Adnan [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany); Ott, Ilka; Fusaro, Massimiliano [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany)

    2015-04-15

    Background: The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. A strategy of percutaneous transluminal angioplasty (PTA) with covered stent (CS) may represent a valuable alternative to open surgery. However, systematic evaluations of CS in this setting represent a scientific gap. In the present study, we investigate the procedural and clinical outcomes associated with PTA and CS implantation to repair iatrogenic injuries of peripheral arteries. Methods: All patients undergoing PTA with CS for endovascular repair of iatrogenic injuries of peripheral arteries between August 2010 and July 2013 at our Institution were retrospectively analyzed. The primary endpoint was the technical success. Secondary endpoints were in-hospital mortality and cumulative death, target lesion revascularization (TLR), amputation and major stroke at 12-month follow-up. Results: During the period of observation, a total of 30 patients underwent PTA with either self-expandable (43.3%) or balloon-expandable CS (56.7%) for iatrogenic injuries of peripheral arteries. Injuries consisted of perforation/rupture (76.7%), arteriovenous fistula (16.7%) and pseudoaneurysm (6.7%) of iliac–femoral arteries. Technical success was achieved in all cases. Median follow-up was 409 days [210–907]. The incidence of in-hospital mortality was 10.0%. At 12-month follow-up, the incidence of death, TLR, amputation and major stroke was 20.0%, 17.0%, 3.3% and 6.7%, respectively. Conclusion: The use of covered stents for endovascular repair of iatrogenic injuries of peripheral arteries shows a high technical success and may be alternative to surgery. Further studies with larger populations are needed to confirm these preliminary findings. - Highlights: • The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. • Percutaneous transluminal angioplasty with

  17. Postinterventional subarachnoid haemorrhage after endovascular stroke treatment with stent retrievers

    Energy Technology Data Exchange (ETDEWEB)

    Nikoubashman, Omid [Uniklinik Aachen, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Aachen (Germany); Institute for Neuroscience and Medicine 4, Juelich (Germany); Reich, Arno; Jungbluth, Michael [Uniklinik Aachen, Klinik fuer Neurologie, Aachen (Germany); Pjontek, Rastislav; Wiesmann, Martin [Uniklinik Aachen, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Aachen (Germany)

    2014-12-15

    The purpose of this paper is to investigate the clinical significance of postinterventional subarachnoid hyperdensities (PSH) after endovascular mechanical thrombectomy in acute ischemic stroke. We analysed clinical and radiological data of 113 consecutive patients who received postinterventional CT scans within 4.5 h after mechanical thrombectomy. PSH was present in 27 of 113 patients (24 %). Extravasation of contrast agent was observed during intervention in only 6 of 27 cases (22 %). There was consecutive haemorrhagic transformation in four patients with PSH (p = 0.209, Fisher's exact test). Preinterventional predictors for the occurrence of PSH in our series were a long interval between clinical onset and recanalization (p = 0.028), a long procedure time (p = 0.010), and a high number of recanalization attempts (p = 0.001). PSH had no significant impact on clinical outcome (modified Rankin Scale) at discharge (p = 0.419) or at 3 months (p = 0.396). There were no significant correlations between PSH and thrombectomy devices (Solitaire: p = 0.433, Trevo Pro: p = 0.124). PSH after endovascular mechanical thrombectomy in acute ischemic stroke are likely to occur in complicated cases in which more than one revascularisation attempt is performed. PSH per se do not appear to be associated with an impaired clinical outcome or an elevated risk for consecutive haemorrhage. (orig.)

  18. Impact of Hospital Volume on Outcomes of Endovascular Stenting for Adult Aortic Coarctation.

    Science.gov (United States)

    Bhatt, Parth; Patel, Nileshkumar J; Patel, Achint; Sonani, Rajesh; Patel, Aashay; Panaich, Sidakpal S; Thakkar, Badal; Savani, Chirag; Jhamnani, Sunny; Patel, Nilay; Patel, Nish; Pant, Sadip; Patel, Samir; Arora, Shilpkumar; Dave, Abhishek; Singh, Vikas; Chothani, Ankit; Patel, Jay; Ansari, Mohammad; Deshmukh, Abhishek; Bhimani, Ronak; Grines, Cindy; Cleman, Michael; Mangi, Abeel; Forrest, John K; Badheka, Apurva O

    2015-11-01

    Use of transcatheter endovascular stenting has been increasing in the treatment of coarctation of aorta (CoA). The present study was undertaken on adults with CoA who underwent stent placement from 2000 to 2011 to analyze the relation of hospital volumes to the outcomes of stenting in adults with CoA. It was a retrospective study based on Healthcare Cost and Utilization Project's Nationwide Inpatient Sample (NIS) database from 2000 to 2011 and identified subjects using the International Classification of Diseases, Ninth Revision, Clinical Modification procedure code of 747.10 (CoA). Annual hospital volume was calculated using unique hospital identifiers. Weights provided by the Nationwide Inpatient Sample were used to generate national estimates. A total of 105 (weighted 521) subjects were identified with International Classification of Diseases, Ninth Revision, code of 39.90 (Endovascular stent). Hospital volumes were divided into tertiles. We compared the highest tertile (≥3 procedures annually) with other tertiles (<3 procedure annually). The composite outcomes of the analysis were procedure-related complications, length of stay (LOS), and cost in relation to the hospital volume. No inhospital death was reported in either group. Hospitals with ≥3 procedures annually had significantly lower incidence of complications (9.5% vs 23.0%) compared to the hospitals with <3 procedures annually (p-value 0.002). Similar results were obtained after multivariate regression analysis in relation to hospital volume. Shorter LOS and lower cost were observed with annual hospital volume of ≥3 procedures. In conclusion, stenting adults for CoA is remarkably safe, and the outcomes of the procedure have improved in centers with annual hospital volume of ≥3 procedures. There is also decreasing trend of procedure-related complications, shorter LOS, and lower costs compared to centers with annual volume <3 procedures.

  19. Cardiovascular changes in children with coarctation of the aorta treated by endovascular stenting.

    Science.gov (United States)

    Sezer, S S; Narin, N; Ozyurt, A; Onan, S H; Pamukcu, O; Argun, M; Baykan, A; Uzum, K

    2014-06-01

    The aim of this study was to investigate the echocardiographic, biochemical short- and mid-term effects of the stenting procedure on left ventricular function, aortic stiffness, elasticity and systemic hypertension in children with coarctation of the aorta (CoA). Fifteen patients with native or recurrent CoA and 30 healthy controls who were sex and age matched were included in the study. The blood pressure values, echocardiographic measurements, elastic functions of ascending aorta and serum N-Terminal ProBNP (NT-ProBNP) levels were recorded prospectively before and at the first and sixth month after stenting. The mean arterial pressure recorded before stenting was 134.4±16.3 mm Hg; at the sixth month it was 115.5±9.5 mm Hg and in the control group it was 107.3±9.4 mm Hg. Although blood pressure levels were lower compared with the pre-stenting measurements (Pcoarctation by endovascular stenting led to a reduction in the arteriopathy that had already begun before treatment, it was demonstrated that these children did not completely return to normal.

  20. A Literature Review of the Numerical Analysis of Abdominal Aortic Aneurysms Treated with Endovascular Stent Grafts

    Directory of Open Access Journals (Sweden)

    David Roy

    2012-01-01

    Full Text Available The purpose of this paper is to present the basic principles and relevant advances in the computational modeling of abdominal aortic aneurysms and endovascular aneurysm repair, providing the community with up-to-date state of the art in terms of numerical analysis and biomechanics. Frameworks describing the mechanical behavior of the aortic wall already exist. However, intraluminal thrombus nonhomogeneous structure and porosity still need to be well characterized. Also, although the morphology and mechanical properties of calcifications have been investigated, their effects on wall stresses remain controversial. Computational fluid dynamics usually assumes a rigid artery wall, whereas fluid-structure interaction accounts for artery compliance but is still challenging since arteries and blood have similar densities. We discuss alternatives to fluid-structure interaction based on dynamic medical images that address patient-specific hemodynamics and geometries. We describe initial stresses, elastic boundary conditions, and statistical strength for rupture risk assessment. Special emphasis is accorded to workflow development, from the conversion of medical images into finite element models, to the simulation of catheter-aorta interactions and stent-graft deployment. Our purpose is also to elaborate the key ingredients leading to virtual stenting and endovascular repair planning that could improve the procedure and stent-grafts.

  1. Endovascular Treatment of Internal Carotid and Vertebral Artery Aneurysms Using a Novel Pericardium Covered Stent

    Science.gov (United States)

    Vulev, I.; Klepanec, A.; Bazik, R.; Balazs, T.; Illes, R.; Steno, J.

    2012-01-01

    Summary Intracranial aneurysm is a fairly common (often asymptomatic) condition. Subarachnoid hemorrhage associated with aneurysmal rupture is a potentially lethal event with a mortality rate as high as 50 percent and a high rate of disability among those who survive the initial hemorrhage, such that recently published guidelines support treatment of intracerebral aneurysms. The current treatment options include surgical clipping and endovascular treatment, but these are not without significant problems. Despite the trend toward endovascular treatment the rate of recurrence and complications is high. Current published evidence of the use of covered stent is limited to stents covered with polytetrafluoroethylene. It is now recognized that mammalian extracellular matrix represents an excellent scaffold material suitable for many therapeutic applications and glutaraldehyde treated pericardium has been widely used for many years due to its desirable features such as low immunogenicity and durability. This report describes the first published experience with the Aneugraft Pericardium Covered Stent (ITGI Medical, OR Akiva, Israel) in the treatment of internal carotid and vertebral artery aneurysms in three patients. In all three cases, the implantation of this novel device has resulted in successful closure of aneurysms. PMID:22681731

  2. Intracranial stents in the endovascular treatment of acute ischemic stroke.

    Science.gov (United States)

    Delgado Acosta, F; Jiménez Gómez, E; Bravo Rey, I; Bravo Rodríguez, F A; Ochoa Sepúlveda, J J; Oteros Fernández, R

    To evaluate the efficacy and safety of intracranial stenting as a rescue therapy after failed mechanical thrombectomy in patients with acute ischemic stroke. We retrospectively studied 42 patients treated with intracranial stenting after failed mechanical thrombectomy between December 2008 and January 2016. We compared outcomes before and after the incorporation of stentrievers. We assessed the degree of recanalization in the carotid and basilar territories (modified TIMI score), prognostic factors, and outcome (modified Rankin Score at 3 months). Safety was evaluated in function of the appearance of symptomatic intracranial hemorrhage (SICH). Median NIHSS was 17 in patients with carotid territory strokes and 26 in those with vertebrobasilar territory strokes. Median time from onset of symptoms to treatment was 225minutes in carotid territory strokes and 390minutes in vertebrobasilar territory strokes. A total of 10 patients underwent intravenous fibrinolytic therapy before treatment with stentrievers. Two patients developed SICH; both had undergone intravenous fibrinolytic therapy (p=0.0523). Recanalization was effective in 30 (71.4%) in the entire series: in 7 (50%) of 14 patients treated before the incorporation of stentrievers and in 23 (82.1%) of 28 treated after the incorporation of stentrievers (p=0.0666). Outcome at 3 months was good in 2 (14.3%) patients in the earlier group and in 14 (50%) patients in the later group (p=0.042). We found significant associations between recanalization and outcome (p=0.0415) and between shorter time to treatment and outcome (p=0.002). Outcome was good in 14 (48.3%) of the 29 patients with carotid territory strokes and in 2 (15.4%) of the 13 patients with vertebrobasilar territory strokes (p=0.078). Intracranial stenting is the rescue treatment when the usual treatment fails. Stentrievers must be used to eliminate the clot burden before stenting. In our study, antiplatelet treatment did not seem to increase the risk of SICH

  3. Contrast Medium Induced Nephropathy after Endovascular Stent Graft Placement: An Examination of Its Prevalence and Risk Factors

    Directory of Open Access Journals (Sweden)

    Yohei Kawatani

    2016-01-01

    Full Text Available Endovascular stent graft placement has become a major treatment for thoracic and abdominal aneurysms. While endovascular therapy is less invasive than open surgery, it involves the use of a contrast medium. Contrast media can cause renal impairment, a condition termed as contrast-induced nephropathy (CIN. This study sought to evaluate the incidence and risk factors of CIN following endovascular stent graft placement for aortic aneurysm repair. The study included 167 consecutive patients who underwent endovascular stent graft placement in our hospital from October 2013 to June 2014. CIN was diagnosed using the European Society of Urogenital Radiology criteria. Patients with and without CIN were compared. Chi-squared tests, t-tests, and multivariate logistic regression analyses were performed. Thirteen patients (7.8% developed CIN. Left ventricular dysfunction and intraoperative blood transfusion were significantly more frequent in the CIN group (P=0.017 and P=0.032, resp.. Multivariate analysis showed that left ventricular dysfunction had the strongest influence on CIN development (odds ratio 9.34, P=0.018, and 95% CI = 1.46–59.7. Patients with CIN also experienced longer ICU and hospital stays. Measures to improve renal perfusion flow should be considered for patients with left ventricular dysfunction who are undergoing endovascular stent graft placement.

  4. Early Stent Graft Perforation after Endovascular Repair for Pseudoaneurysm That Was Associated with Clavicle Nonunion

    Science.gov (United States)

    Touma, Masanao; Ohno, Nobuhisa; Yoshikawa, Eiji; Yoshizawa, Kousuke; Fujiwara, Keiichi

    2015-01-01

    We report the case of a 62-year-old man who experienced a left axillary artery pseudoaneurysm that was secondary to nonunion of a 30-year-old left midshaft clavicle fracture. He initially underwent endovascular repair using a self-expanding nitinol stent graft, which was perforated at postoperative day 5. Therefore, we performed open repair with concomitant clavicle resection, and no complications were observed during an approximately 6-year follow-up. We recommend performing clavicle resection with vascular repair to prevent recurrence in similar cases. PMID:26421082

  5. Endovascular Treatment of Blunt Traumatic Abdominal Aortic Occlusion With Kissing Stent Placement

    Energy Technology Data Exchange (ETDEWEB)

    Idoguchi, Koji, E-mail: idoguchi@ares.eonet.ne.jp; Yamaguchi, Masato; Okada, Takuya [Kobe University Hospital, Department of Radiology and Center for Endovascular Therapy (Japan); Nomura, Yoshikatsu [Kobe University Hospital, Department of Cardiovascular Surgery (Japan); Sugimura, Kazuro [Kobe University Hospital, Department of Radiology and Center for Endovascular Therapy (Japan); Okita, Yutaka [Kobe University Hospital, Department of Cardiovascular Surgery (Japan); Sugimoto, Koji [Kobe University Hospital, Department of Radiology and Center for Endovascular Therapy (Japan)

    2012-10-15

    Blunt traumatic abdominal aortic dissection is extremely rare and potentially deadly. We present the case of a 62-year-old man involved in a frontal car crash. After emergency undergoing laparotomy for bowel injuries, he was referred to our hospital due to acute ischemia of bilateral lower extremities on day 3 after the trauma. Computed tomography and aortography showed an aortobiiliac dissection with complete occlusion. This injury was successfully treated by endovascular treatment with 'kissing'-technique stent placement, which appears to be a safe, effective, and minimally invasive treatment.

  6. Radial forces of stents used in thoracic endovascular aortic repair and bare self-expanding nitinol stents measured ex vivo - Rapid rescue for obstruction of the innominate artery using bare self-expanding nitinol stents.

    Science.gov (United States)

    Matsumoto, Takuya; Inoue, Kentaro; Tanaka, Shinichi; Aoyagi, Yukihiko; Matsubara, Yutaka; Matsuda, Daisuke; Yoshiya, Keiji; Yoshiga, Ryosuke; Ohkusa, Tomoko; Maehara, Yoshihiko

    2017-02-01

    Purpose Our objective was to compare the radial forces of several stents ex vivo to identify stents suitable for rescue of the unexpected coverage of aortic arch branches in thoracic endovascular aortic repair. Methods We measured the radial forces of two types of self-expanding bare nitinol stents (E-luminexx and Epic) used singly or as double-walled pairs, and of three endoprostheses used in thoracic endovascular aortic repair (TEVAR, Gore c-TAG, Relay, and Valiant) by compressing the stent using an MTS Instron universal testing machine (model #5582). We also examined the compressive effects of the TEVAR endoprostheses and the bare nitinol stents on each other. Results The radial force was greater in the center than at the edge of each stent. In all stents tested, the radial force decreased incrementally with increasing stent diameter. The radial force at the center was two times greater when using two stents than with a single stent. In the compression test, only E-luminexx used as a pair was not compressed after compressing a Relay endoprosthesis by 12 mm. Conclusion Two E-luminexx stents are appropriate to restore the blood flow if a TEVAR endoprosthesis covers the innominate artery following innominate-carotid-left subclavian arterial bypass.

  7. Treatment of internal carotid artery dissections with endovascular stent placement: report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Deok Hee; Hur, Seung Ho; Kim, Hyeon Gak; Jung, Seung Mun; Ryu, Dae Sik; Park, Man Soo [Kangnung Hospital, Kangnung (Korea, Republic of)

    2000-03-01

    Extracranial carotid artery dissection may manifest as arterial stenosis or occlusion, or as dissecting aneurysm formation. Anticoagulation and/or antiplatelet therapy is the first-line treatment, but because it is effective and less invasive than other procedures, endovascular treatment of carotid artery dissection has recently attracted interest. We encountered two consecutive cases of trauma-related extracranial internal carotid artery dissection, one in the suprabulbar portion and one in the subpetrosal portion. We managed the patient with suprabulbar dissection using a self-expandable metallic stent and managed the patient with subpetrosal dissection using a balloon-expandable metallic stent. In both patients the dissecting aneurysm disappeared, and at follow-up improved luminal patency was observed.

  8. Tuberculous aneurysm of the abdominal aorta: endovascular repair using stent grafts in two cases

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wei Chiang; Kwak, Byung Kook; Kim, Kyo Nam [Sung Ae General Hospital, Seoul (Korea, Republic of); And Others

    2000-12-01

    Tuberculous aneurysm of the aorta is exceedingly rare. To date, the standard therapy for mycotic aneurysm of the abdominal aorta has been surgery involving in-situ graft placement or extra-anatomic bypass surgery followed by effective anti-tuberculous medication. Only recently has the use of a stent graft in the treatment of tuberculous aortic aneurysm been described in the literature. We report two cases in which a tuberculous aneurysm of the abdominal aorta was successfully repaired using endovascular stent grafts. One case involved is a 42-year-old woman with a large suprarenal abdominal aortic aneurysm and a right psoas abscess, and the other, a 41-year-old man in whom an abdominal aortic aneurysm ruptured during surgical drainage of a psoas abscess. (author)

  9. Computational fluid dynamics evaluation of the cross-limb stent graft configuration for endovascular aneurysm repair.

    Science.gov (United States)

    Shek, Tina L T; Tse, Leonard W; Nabovati, Aydin; Amon, Cristina H

    2012-12-01

    The technique of crossing the limbs of bifurcated modular stent grafts for endovascular aneurysm repair (EVAR) is often employed in the face of splayed aortic bifurcations to facilitate cannulation and prevent device kinking. However, little has been reported about the implications of cross-limb EVAR, especially in comparison to conventional EVAR. Previous computational fluid dynamics studies of conventional EVAR grafts have mostly utilized simplified planar stent graft geometries. We herein examined the differences between conventional and cross-limb EVAR by comparing their hemodynamic flow fields (i.e., in the "direct" and "cross" configurations, respectively). We also added a "planar" configuration, which is commonly found in the literature, to identify how well this configuration compares to out-of-plane stent graft configurations from a hemodynamic perspective. A representative patient's cross-limb stent graft geometry was segmented using computed tomography imaging in Mimics software. The cross-limb graft geometry was used to build its direct and planar counterparts in SolidWorks. Physiologic velocity and mass flow boundary conditions and blood properties were implemented for steady-state and pulsatile transient simulations in ANSYS CFX. Displacement forces, wall shear stress (WSS), and oscillatory shear index (OSI) were all comparable between the direct and cross configurations, whereas the planar geometry yielded very different predictions of hemodynamics compared to the out-of-plane stent graft configurations, particularly for displacement forces. This single-patient study suggests that the short-term hemodynamics involved in crossing the limbs is as safe as conventional EVAR. Higher helicity and improved WSS distribution of the cross-limb configuration suggest improved flow-related thrombosis resistance in the short term. However, there may be long-term fatigue implications to stent graft use in the cross configuration when compared to the direct

  10. Multiple multilayer stents for thoracoabdominal aortic aneurysm: a possible new tool for aortic endovascular surgery

    Directory of Open Access Journals (Sweden)

    Tolva VS

    2012-07-01

    Full Text Available Valerio Stefano Tolva,1,3 Paolo Guy Bianchi,1 Lea Valeria Cireni,1 Alma Lombardo,1 Guido Carlo Keller,1 Gianfranco Parati,2,3 Renato Maria Casana11Surgical Department Istituto Auxologico Italiano IRCCS, Milan, Italy; 2Department of Cardiology, Istituto Auxologico Italiano, Università degli Studi di Milano-Bicocca, Bicocca, Milan, Italy; 3Department of Internal Medicine, San Gerardo Hospital, Università degli Studi di Milano-Bicocca, Bicocca, Milan, ItalyPurpose: Endovascular surgery data are confirming the paramount role of modern endovascular tools for a safe and sure exclusion of thoracoabdominal lesions.Case report: A 57-year-old female presented with severe comorbidity affected by a 58 mm thoracoabdominal aortic aneurysm (TAAA. After patient-informed consent and local Ethical Committee and Italian Public Health Ministry authorization, three multilayer stents were implanted in the thoracoabdominal aortic tract, obtaining at a 20-month computed tomography scan follow up, a complete exclusion of the TAAA, with normal patency of visceral vessels.Conclusion: Multilayer stents can be used in thoracoabdominal aortic aneurysm, with positive results.Keywords: chimney technique, renal artery stenosis, thoracoabdominal aneurysm, vascular complication

  11. Effect of radioactivity on stent-graft incorporation after endovascular treatment of aneurysms: An animal study.

    Science.gov (United States)

    Lerouge, Sophie; Raymond, Jean; Schloesser, Klaus; Gaboury, Louis; Soulez, Gilles

    2006-12-01

    Poor stent-graft (SG) incorporation into the vessel wall, following endovascular repair of abdominal aortic aneurysms (EVAR), can lead to endoleaks and SG migration. Low-dose radiation can prevent aneurysm recurrence after coil embolization, and has been associated with a "paradoxical" increase in neointima formation after stenting in a few studies. It was hypothesized that in situ beta radiation emitted from SG could improve its incorporation by preventing the persistence of circulating channels between the implant and the vessel wall and increasing neointima formation around the SG. Phosphorus 32 ((32)P, 200 or 400 kBq per SG (n = 6 each)) was ion implanted on the external surface of balloon-expandable SGs. Twelve radioactive and six non-radioactive SGs were deployed in iliac arteries of nine Mongrel dogs. Neointima formation inside the graft and the persistence of circulating flow through an artificial groove created during the endovascular procedure were assessed by follow-up imaging and by blinded, computerized histomorphometric analysis after animal sacrifice at 3 months. Occlusion occurred in four radioactive SGs. A lesser number of patent grooves was observed along high-activity SGs than along control SGs (1/3 versus 4/4). No difference in neointima formation was observed in radioactive and non-radioactive SGs. Alteration of external graft surface was observed after ion implantation. Ion implantation of (32)P on SGs does not seem to be a viable strategy to improve incorporation and prevent type-I endoleak after EVAR.

  12. In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease

    NARCIS (Netherlands)

    Groot Jebbink, Erik; Ter Mors, Thijs G; Slump, Cornelis H; Geelkerken, Robert H; Holewijn, Suzanne; Reijnen, Michel MPJ

    2017-01-01

    Objectives Various configurations of kissing stent (KS) configurations exist and patency rates vary. In response the covered endovascular reconstruction of the aortic bifurcation configuration was designed to minimize mismatch and improve outcome. The aim of the current study is to compare

  13. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    , covering, endovascular, revascularisation and thoracic aorta. We have gathered the most complete scientific evidence available used to support the various concepts to deal with this issue. After a review of the current available literature, 23 relevant articles were found, where we have identified......Thoracic endovascular aortic repair (TEVAR) has emerged as a promising therapeutic alternative to conventional open aortic replacement but it requires suitable proximal and distal landing zones for stent-graft anchoring. Many aortic pathologies affect in the immediate proximity of the left...... subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre...

  14. Percutaneous endovascular stent-graft treatment of aortic aneurysms and dissections: new techniques and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Choi, Dong Hoon; Kang, Sung Gwon; Lee, Kwang Hoon; Won, Jong Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kang, Sung Gwon [Chosun University College of Medicine, Gwangju (Korea, Republic of); Won, Je Whan [Aju University College of Medicine, Suwon (Korea, Republic of); Song, Ho Young [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2003-01-01

    To evaluate the feasibility, safety and effectiveness of a newly designed percutaneously implanted separate stent-graft (SSG) for the treatment of aortic aneurysms and dissections. Using a percutaneous technique, SSG placement (in the descending thoracic aorta in 26 cases and infrarenal abdominal aorta in 24) was attempted in 50 patients with aortic aneurysms (n=27) or dissection (n=23). All SSGs were individually constructed using self-expandable nitinol stents and a Dacron graft, and were introduced through a 12 F sheath and expanded to a diameter of 20-34 mm. In all cases, vascular access was through the femoral artery. The clinical status of each patient was monitored, and postoperative CT was performed within one week of the procedure and at 3-6 month intervals afterwards. Endovascular stent-graft deployment was technically successful in 49 of 50 patients (98%). The one failure was due to torsion of the unsupported graft during deployment. Successful exclusion of aneurysms and the primary entry tears of dissections was achieved in all but three patients with aortic dissection. All patients in whom technical success was achieved showed complete thrombosis of the thoracic false lumen or aneurysmal sac, and the overall technique success rate was 92%. In addition, sixteen patients demonstrated complete resolution of the dissected thoracic false lumen (n=9) or aneurysmal sac (n=7). Immediate post-operative complications occurred at the femoral puncture site in one patient with an arteriovenous fistula, and in two, a new saccular aneurysm developed at the distal margin of the stent. No patients died, and there was no instance of paraplegia, stroke, side-branch occlusion or infection during the subsequent mean follow-up period of 9.4 (range, 2 to 26) months. In patients with aortic aneurysm and dissection, treatment with a separate percutaneously inserted stent-graft is technically feasible, safe, and effective.

  15. Endovascular treatment of aortoiliac aneurysms: From intentional occlusion of the internal iliac artery to branch iliac stent graft

    Institute of Scientific and Technical Information of China (English)

    Stevo Duvnjak

    2016-01-01

    Approximately 20%-40% of patients with abdominal aortic aneurysms can have unilateral or bilateral iliac artery aneurysms and/or ectasia. This influences and compromises the distal sealing zone during endovascular aneurysm repair. There are a few endovascular techniques that are used to treat these types of aneurysms, including intentional occlusion/over-stenting of the internal iliac artery on one or both sides, the "bell-bottom" technique, and the more recent method of using an iliac branch stent graft. In some cases, other options include the "snorkel and sandwich" technique and hybrid interventions. Pelvic ischemia, represented as buttock claudication, has been reported in 16%-55% of cases; this is followed by impotence, which has been described in 10%-17% of cases following internal iliac artery occlusion. The bellbottom technique can be used for a common iliac artery up to 24 mm in diameter given that the largest diameter of the stent graft is 28 mm. There is a paucity of data and evidence regarding the "snorkel and sandwich" technique, which can be used in a few clinical scenarios. The hybrid intervention is comprised of a surgical operation, and is not purely endovascular. The newest branch stent graft technology enables preservation of the anterograde flow of important side branches. Technical success with the newest technique ranges from 85%-96.3%, and in some small series, technical success is 100%. Buttock claudication was reported in up to 4% of patients treated with a branch stent graft at 5-year follow-up. Mid- and short-term follow-up results showed branch patency of up to 88% during the 5-6-year period. Furthermore, branch graft occlusion is a potential complication, and it has been described to occur in 1.2%-11% of cases. Iliac branch stent graft placement represents a further development in endovascular medicine, and it has a high technical success rate without serious complications.

  16. Supera self-expanding stents for endovascular treatment of femoropopliteal disease: a review of the clinical evidence

    Directory of Open Access Journals (Sweden)

    Bishu K

    2015-07-01

    Full Text Available Kalkidan Bishu,1,2 Ehrin J Armstrong1,21Division of Cardiology, University of Colorado, Aurora, 2Denver VA Medical Center, Denver, CO, USAAbstract: Femoropopliteal lesions account for a significant proportion of endovascular interventions for peripheral artery disease in patients with disabling claudication or chronic limb ischemia. The femoropopliteal artery crosses two joint structures (hip and knee joints and courses through the muscular adductor canal in the thigh, which places the artery at increased biomechanical stress. There is a critical need for stent platforms with a reduced risk of stent fracture while maintaining patency during long-term follow-up. The Supera peripheral stent system has a braided nickel–titanium alloy stent designed to withstand the unique stressors along the course of the femoropopliteal artery. This design may be associated with improved patency in association with reduced stent fracture rates on short- and medium-term follow-up. Further studies, including randomized controlled studies, comparing the Supera interwoven nickel–titanium alloy stent system with other stent platforms and angioplasty alone are needed.Keywords: peripheral artery disease, femoropopliteal atherosclerosis, SUPERA interwoven nitinol stent, stent fracture

  17. Short-term curative effect of endovascular stent-graft treatment for aortic diseases in China: a systematic review.

    Directory of Open Access Journals (Sweden)

    Siwen Wang

    Full Text Available INTRODUCTION: We analyzed the short-term efficacy of endovascular treatment for aortic diseases by summarizing all available published data on endovascular stent-graft treatment for abdominal aortic aneurysm (AAA, thoracic aortic aneurysm (TAA, type A aortic dissection (type A AD and type B aortic dissection (type B AD in China. METHODS: We performed a systematic analysis of 935 published series on retrograde endovascular treatment for aortic diseases in China from January 1996 to November 2010. Based on the inclusion criteria, 159 studies, involving a total of 5531 patients, were included. RESULTS: There were no significant differences in procedural success among the studies (P>0.05. The rates of overall neurologic complications and stroke were significantly different in all two-group comparisons (P0.05. A significant difference was noted between the 30-day mortality rate of the type A AD patients and the AAA or type B AD patients (P<0.05. CONCLUSION: Endovascular stent-graft is a feasible and safe treatment for aortic diseases, with high procedural success and low incidences of post-procedural complications and short-term mortality. Endovascular treatment for AAA and type B AD is more efficient than for type A AD and TAA.

  18. Potential Long-Term Complications of Endovascular Stent Grafting for Blunt Thoracic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Larry E. Miller

    2012-01-01

    Full Text Available Blunt thoracic aortic injury (BTAI is a rare, but lethal, consequence of rapid deceleration events. Most victims of BTAI die at the scene of the accident. Of those who arrive to the hospital alive, expedient aortic intervention significantly improves survival. Thoracic endovascular aortic repair (TEVAR has been accepted as the standard of care for BTAI at many centers, primarily due to the convincing evidence of lower mortality and morbidity in comparison to open surgery. However, less attention has been given to potential long-term complications of TEVAR for BTAI. This paper focuses on these complications, which include progressive aortic expansion with aging, inadequate stent graft characteristics, device durability concerns, long-term radiation exposure concerns from follow-up computed tomography scans, and the potential for (Victims of Modern Imaging Technology VOMIT.

  19. Surgeon leadership in the coding, billing, and contractual negotiations for fenestrated endovascular aortic aneurysm repair increases medical center contribution margin and physician reimbursement.

    Science.gov (United States)

    Aiello, Francesco; Durgin, Jonathan; Daniel, Vijaya; Messina, Louis; Doucet, Danielle; Simons, Jessica; Jenkins, James; Schanzer, Andres

    2017-10-01

    Fenestrated endovascular aneurysm repair (FEVAR) allows endovascular treatment of thoracoabdominal and juxtarenal aneurysms previously outside the indications of use for standard devices. However, because of considerable device costs and increased procedure time, FEVAR is thought to result in financial losses for medical centers and physicians. We hypothesized that surgeon leadership in the coding, billing, and contractual negotiations for FEVAR procedures will increase medical center contribution margin (CM) and physician reimbursement. At the UMass Memorial Center for Complex Aortic Disease, a vascular surgeon with experience in medical finances is supported to manage the billing and coding of FEVAR procedures for medical center and physician reimbursement. A comprehensive financial analysis was performed for all FEVAR procedures (2011-2015), independent of insurance status, patient presentation, or type of device used. Medical center CM (actual reimbursement minus direct costs) was determined for each index FEVAR procedure and for all related subsequent procedures, inpatient or outpatient, 3 months before and 1 year subsequent to the index FEVAR procedure. Medical center CM for outpatient clinic visits, radiology examinations, vascular laboratory studies, and cardiology and pulmonary evaluations related to FEVAR were also determined. Surgeon reimbursement for index FEVAR procedure, related adjunct procedures, and assistant surgeon reimbursement were also calculated. All financial analyses were performed and adjudicated by the UMass Department of Finance. The index hospitalization for 63 FEVAR procedures incurred $2,776,726 of direct costs and generated $3,027,887 in reimbursement, resulting in a positive CM of $251,160. Subsequent related hospital procedures (n = 26) generated a CM of $144,473. Outpatient clinic visits, radiologic examinations, and vascular laboratory studies generated an additional CM of $96,888. Direct cost analysis revealed that grafts

  20. Use of endovascular stents in atherosclerotic renovascular stenosis: blood pressure and renal function changes in hypertensive patients.

    Science.gov (United States)

    Tagle, Rodrigo; Acevedo, Monica; Xu, Meng; Pohl, Marc; Vidt, Donald

    2007-08-01

    Atherosclerotic renal artery stenosis may result in hypertension and ischemic nephropathy. Renal artery endovascular stenting has emerged as current therapy; however, the percentage of patients who benefit from this procedure is still not well established. The authors studied 116 hypertensive patients with atherosclerotic renovascular stenosis who underwent successful renal artery stenting for the first time. At 1 year, there was a significant overall decrease in blood pressure in the group after stenting; however, there was no change in renal function. Also, no significant change in the number of antihypertensive drugs was noted. Blood pressure improved in 55% of the patients, worsened in 14%, and remained unchanged in 31%. Renal function improved in 16% of the patients, worsened in 30%, and remained stable in 54%. In relation to blood pressure control, patients with resistant or difficult-to-control hypertension showed the most improvement in blood pressure control after stenting.

  1. Association between the SVS/AAVS anatomical severity grading score and operative outcomes in fenestrated endovascular repair of juxtarenal aortic aneurysm.

    Science.gov (United States)

    Kristmundsson, Thorarinn; Sonesson, Björn; Dias, Nuno; Malina, Martin; Resch, Timothy

    2013-06-01

    To evaluate the association between the Society for Vascular Surgery/American Association for Vascular Surgery (SVS/AAVS) anatomical severity grading (ASG) score and operative outcomes in fenestrated endovascular repair (f-EVAR) for juxtarenal aortic aneurysm. A review was conducted of all patients treated at our clinic with commercially available, custom-made f-EVAR devices between June 2007 and December 2011. Preoperative computed tomography (CT) scans were analyzed in a dedicated vascular 3-dimensional workstation for calculation of the ASG score. Of the 100 patients treated with f-EVAR during the study period, 88 (69 men; mean age 70 years, range 50-82) had high quality CT scans available for generating semiautomatic centerline-of-flow reconstructions needed to calculate the ASG score. The mean score was used to divide the patients into high and low score groups for comparison of operative outcomes. A total ASG score ≥24 was associated with longer procedure time (357±121 vs. 298±131 minutes, p=0.03) and more frequent intraoperative adjunctive maneuvers (48% vs. 29% of patients, p=0.05). An ASG neck score ≥7 was associated with longer procedure time (365±126 vs. 288±119 minutes, p<0.01), more operative adverse events (31% vs. 14% of patients, p=0.05), higher radiation exposure (53828±37341 vs. 38788±25846 μGym(2), p=0.04), and more frequent postoperative complications (46% vs. 18% of patients, p<0.01). An ASG aneurysm score ≥5 was associated with operative adverse events (44% vs. 19% of patients, p=0.04). No relationship was found between the ASG score and blood loss, contrast volume, fluoroscopy time, or hospital stays. The ASG score is associated with operative adverse events, intraoperative adjunctive maneuvers, radiation exposure, and postoperative complications in patients treated with f-EVAR for juxtarenal aortic aneurysm.

  2. Endovascular repair of arterial iliac vessel wall lesions with a self-expandable nitinol stent graft system.

    Directory of Open Access Journals (Sweden)

    Birger Mensel

    Full Text Available OBJECTIVE: To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs using a self-expandable Nitinol stent graft system. METHODS: Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications. RESULTS: The primary technical and clinical success rate was 81.3% (13/16 patients and 75.0% (12/16, respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16 and 93.8% (15/16. The minor complication rate was 6.3% (patient with painful hematoma at the access site. The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis. During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed. CONCLUSION: Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.

  3. Applying value stream mapping techniques to eliminate non-value-added waste for the procurement of endovascular stents.

    Science.gov (United States)

    Teichgräber, Ulf K; de Bucourt, Maximilian

    2012-01-01

    OJECTIVES: To eliminate non-value-adding (NVA) waste for the procurement of endovascular stents in interventional radiology services by applying value stream mapping (VSM). The Lean manufacturing technique was used to analyze the process of material and information flow currently required to direct endovascular stents from external suppliers to patients. Based on a decision point analysis for the procurement of stents in the hospital, a present state VSM was drawn. After assessment of the current status VSM and progressive elimination of unnecessary NVA waste, a future state VSM was drawn. The current state VSM demonstrated that out of 13 processes for the procurement of stents only 2 processes were value-adding. Out of the NVA processes 5 processes were unnecessary NVA activities, which could be eliminated. The decision point analysis demonstrated that the procurement of stents was mainly a forecast driven push system. The future state VSM applies a pull inventory control system to trigger the movement of a unit after withdrawal by using a consignment stock. VSM is a visualization tool for the supply chain and value stream, based on the Toyota Production System and greatly assists in successfully implementing a Lean system. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  4. Oclusión de la aorta abdominal infrarrenal. Reconstrucción endovascular con stent

    Directory of Open Access Journals (Sweden)

    Carlos Fernández-Pereira

    2008-01-01

    Full Text Available Introducción La oclusión total de la aorta abdominal es de presentación poco frecuente y afecta más a menudo a mujeres de edad mediana con antecedentes de tabaquismo y dislipidemia. El punto de partida de la terapéutica endovascular en la aorta fue la angioplastia en las arterias ilíacas y fue progresando desde el balón hasta la colocación de stents.ObjetivoComunicar nuestros resultados inmediatos y el seguimiento a mediano plazo de pacientes con oclusión de la aorta abdominal tratadas con stents por vía endovascular.Material y métodosDesde octubre de 1998 a mayo de 2005 en nuestro servicio se trataron 5 pacientes de sexo femenino por oclusión total de la aorta abdominal, con síntomas de claudicación grave de ambos miembros inferiores. Los procedimientos se realizaron con anestesia local y sedación. Por vía femoral, se intenta recanalizar con las cuerdas de Whooley o hidrófila Glidewire. Posteriormente se realiza un angiograma abdominal e intercambio por cuerda Amplatz con la cual se avanza el balón para realizar las dilataciones antes de implantar el stent. Las pacientes con lesiones ilíacas también se trataron con stent. El índice tobillo-brazo era de 0,71. El promedio de hospitalización fue de 2 días. Al alta se indicaron clopidogrel y aspirina como medicación antiplaquetaria, excepto la primera paciente (ticlopidina y aspirina. El seguimiento fue clínico y por ecografía Doppler color a la semana, al mes, a los 6 meses y a los 12 meses.ResultadosLas pacientes eran de sexo femenino, con antecedentes de tabaquismo y dislipidemia. Todos los procedimientos fueron técnicamente exitosos, con mejoría del índice tobillo-brazo a 0,98. Una paciente presentó un hematoma inguinal en el sitio de punción, con buena evolución posterior. En el seguimiento alejado clínico y por ultrasonido se observó una permeabilidad de la aorta del 100%, con estenosis en una paciente tratada a nivel de la arteria ilíaca en el segmento no

  5. Palliative stent graft placement combined with subsequent open surgery for retrograde ascending dissection intra-thoracic endovascular aortic repair

    OpenAIRE

    Zhu, Kai; Lai, Hao; Guo, Changfa; Li, Jun; Wang, Chunsheng

    2014-01-01

    Thoracic endovascular aortic repair (TEVAR) is an effective strategy for type B dissection. Retrograde ascending dissection (RAD) intra-TEVAR is a rare complication on clinic. In this case, a 48-year-old Chinese man with Stanford type B aortic dissection suffered acute RAD during the TEVAR. And palliative stent grafts placement was performed in a local hospital, which earned the time for transfer and subsequent total arch replacement surgery in Zhongshan Hospital Fudan University. This report...

  6. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    Directory of Open Access Journals (Sweden)

    Ying Guan

    2016-08-01

    Full Text Available Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU and polyester graft (nitinol-PET materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.

  7. Endovascular therapy of acute tumour-related obstruction of the superior vena cava using a self-expanding Nitinol stent

    Directory of Open Access Journals (Sweden)

    Peter Kamusella

    2013-11-01

    Full Text Available Objective: To evaluate, in a retrospective study, the clinical efficacy and safety of the self-expanding Nitinol stent in the superior vena cava to alleviate upper venous congestion.Method: In 22 patients (15 men, 7 women, a tumour-related compression of the superior vena cava was diagnosed by spiral CT after intravenous application of contrast medium. Clinically, acute superior vena cava syndrome was found in all patients. Histologically, a bronchial carcinoma was present in 14/22, a lymphoma in 6/22, and mediastinal lymphnode metastases (1 breast carcinoma, 1 malignant melanoma in 2/22. After a transfemoral approach, cavography was initially performed. The degree of stenosis was classified according to the Stanford classification. In accordance with the degree of stenosis, a self-expanding Nitinol stent was placed.Results: Endovascular stent implantation was conducted without complications in all patients. A marked improvement in acute symptoms was observed clinically within 24 hours in all patients. In the follow-up period of up to 2 years, there were no cases of stent migration. In 7/22 patients, the CT follow-ups revealed tumour progression (3/7 after 3 months, 2/7 after 6 months, and 2/7 after 12 months with evidence of residual stenosis caused by tumour growth through the stent mesh. During the follow-up period, 15/22 patients died (mean survival 6.4 months.Conclusion: Self-expanding Nitinol stents provide endovascular therapy for superior vena cava syndrome, having a high radial expansive force and the facility to be placed precisely, and alleviating acute, life-threatening symptoms in the palliative situation.

  8. In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease.

    Science.gov (United States)

    Groot Jebbink, Erik; Ter Mors, Thijs G; Slump, Cornelis H; Geelkerken, Robert H; Holewijn, Suzanne; Reijnen, Michel Mpj

    2017-01-01

    Objectives Various configurations of kissing stent (KS) configurations exist and patency rates vary. In response the covered endovascular reconstruction of the aortic bifurcation configuration was designed to minimize mismatch and improve outcome. The aim of the current study is to compare geometrical mismatch of kissing stent with the covered endovascular reconstruction of the aortic bifurcation configuration in vivo. Methods Post-operative computed tomographic data and patient demographics from 11 covered endovascular reconstruction of the aortic bifurcation and 11 matched kissing stent patients were included. A free hand region of interest and ellipse fitting method were applied to determine mismatch areas and volumes. Conformation of the stents to the vessel wall was expressed using the D-ratio. Results Patients were mostly treated for Rutherford category 2 and 3 (64%) with a lesion classification of TASC C and D in 82%. Radial mismatch area and volume for the covered endovascular reconstruction of the aortic bifurcation group was significantly lower compared to the kissing stent configuration ( P < 0.05). The D-ratio did not significantly differ between groups. Measurements were performed with good intra-class correlation. There were no significant differences in the post-procedural aortoiliac anatomy. Conclusions The present study shows that radial mismatch exists in vivo and that large differences in mismatch exist, in favour of the covered endovascular reconstruction of the aortic bifurcation configuration. Future research should determine if the decreased radial mismatch results in improved local flow profiles and subsequent clinical outcome.

  9. Classification of gutter type in parallel stenting during endovascular aortic aneurysm repair.

    Science.gov (United States)

    Overeem, Simon P; Boersen, Johannes T; Schuurmann, Richte C L; Groot Jebbink, Erik; Slump, Cornelis H; Reijnen, Michel M P J; de Vries, Jean-Paul P M

    2017-08-01

    Gutters can be described as the loss of continuous apposition between the main body of the endograft, the chimney stent graft, and the aortic wall. Gutters have been associated with increased risk of type IA endoleaks and are considered to be the Achilles' heel of chimney endovascular aneurysm repair (ch-EVAR). However, there is no classification yet to classify and quantify gutter types after ch-EVAR. Different gutter types can be distinguished by their morphologic appearance in two- and three-dimensional views and reconstructed slices perpendicular to the center lumen line. Three main categories are defined by (1) the most proximal beginning of the gutter, (2) the length of gutter alongside the endograft, and (3) its distal end. Type A gutters originate at the proximal fabric of an endograft, type B gutters originate as loss of apposition of the chimney stent graft in the branch vessel, and type C gutters start below the fabric of the endograft. To determine eventual changes of gutter size during follow-up computed tomography angiograms (CTAs), measurements may be performed with dedicated software on the follow-up CTA scan to assess the extent of gutters over the aortic circumference, ranging from 0° to 360° of freedom, together with the maximum gap between the endograft material and the aortic wall as it appears on reconstructed axial CTA scan slices. The proposed gutter classification enables a uniform nomenclature in the current ch-EVAR literature and a more accurate risk assessment of gutter-associated endoleaks. Moreover, it allows monitoring of eventual progression of gutter size during follow-up. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  10. Perioperative Occupational Exposure to Coxiella burnetii-Infected Thoracic Endovascular Aneurysm Stent Graft

    Directory of Open Access Journals (Sweden)

    Jade Le

    2017-01-01

    Full Text Available We conducted this study to determine the risk of transmission of Q fever to health care workers (HCWs during perioperative exposure to Coxiella burnetii-infected thoracic endovascular aneurysm stent graft. Pre-operative and 6-week post-operative phase I and II IgG Q fever antibody titers were determined in 14 staff members of an operation room. The room had a negative pressure and all the members of the surgical team wore either a fitted N-95 mask or a powered purified air respirator. Phase I and II IgG antibody titers were <1:16 for 11 of the 14 studied HCWs; 2 HCWs did not follow up at 6 weeks and 1 had a pre-exposure phase II IgG titer of 1:128 with no change 6 weeks later. We concluded that risk of transmission of C. burnetii in the operating room from infected patient to HCWs who wore appropriate personal protective equipment is low.

  11. Endovascular treatment of intrahepatic inferior vena cava obstruction from malignant hepatocellular tumor thrombus utilizing Luminexx self-expanding nitinol stents

    Energy Technology Data Exchange (ETDEWEB)

    Stambo, Glenn W. [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 4516 North Armenia Avenue, Tampa, FL 33603 (United States)], E-mail: xraydoc2@yahoo.com; Leto, John [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 3001 W. Dr. Martin Luther King Jr. Blvd., Tampa, FL 33607 (United States); George, Christopher [Department of Hematology and Oncology, St. Joseph' s Hospital and Medical Center, 4301 W. Habana Avenue, Suite 1, Tampa, FL 33607 (United States); Van Epps, Kelly; Woeste, Troy; Berlet, Mathew [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 4516 North Armenia Avenue, Tampa, FL 33603 (United States)

    2008-05-15

    Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically reliable, and has essentially no morbidity or mortality. This procedure can be performed in the interventional radiology suite with excellent results resolving the IVC syndrome soon after placement of the stents. We believe endovascular stenting as an excellent palliative therapy for patients with IVC syndrome and should be the treatment of choice for caval obstructions due to intraluminal tumor thrombus.

  12. Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hong Suk, E-mail: hongsukpark@gmail.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Do, Young Soo, E-mail: ysdo@skku.edu [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Kim, Duk-Kyung, E-mail: dukkyung.kim@samsung.com [Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, Sung Wook, E-mail: sw.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Shin, Sung Wook, E-mail: sw88.shin@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Cho, Sung Ki, E-mail: sungkismc@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Hyun, Dongho, E-mail: mesentery.hyun@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, In Wook, E-mail: inwook.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of)

    2013-11-01

    Purpose: To retrospectively evaluate and compare the long term patency and antihypertensive effect of angioplasty and stent insertion in renal artery stenosis caused by Takayasu arteritis, with CT angiography and clinical follow-up. Materials and methods: We retrospectively analyzed and compared effects on hypertension and patency of renal artery in 16 patients (age ranging from 16 to 58 years, mean: 32.1 years) with renovascular hypertension caused by Takayasu arteritis who underwent endovascular treatment including angioplasty (n = 13) and stent placement (n = 9) for 22 stenotic renal arteries. Results: Technical success was 95% (21/22) without major complications. In the last follow-up CT angiogram (mean 85 ± 41 months), restenosis was 8% (1/12) in angioplasty and 66% (6/9) in stent. Patency rates of angioplasty were 100%, 91.7%, 91.7% and primary unassisted and primary assisted patency rates of stent placement were 55.6%, 33.3%, 33.3% and 88.9%, 66.7%, 55.6% at 1-, 3- and 5-years, respectively. In clinical follow-up (mean 120 ± 37.8 months, range 48–183 months), beneficial effects on hypertension were obtained in 87% of patients (13/15) and there was no significant difference between the patients who were treated by only angioplasty and the patients who received stent placement in at least one renal artery, regardless of whether or not angioplasty had been performed in the other renal artery. Conclusion: Compared with stent placement, angioplasty demonstrated better long term patency and similar clinical benefit on renovascular hypertension in renal artery stenosis of Takayasu arteritis. We suggest that stent placement should be reserved for obvious angioplasty failure.

  13. Palliative stent graft placement combined with subsequent open surgery for retrograde ascending dissection intra-thoracic endovascular aortic repair

    Science.gov (United States)

    Zhu, Kai; Guo, Changfa; Li, Jun

    2014-01-01

    Thoracic endovascular aortic repair (TEVAR) is an effective strategy for type B dissection. Retrograde ascending dissection (RAD) intra-TEVAR is a rare complication on clinic. In this case, a 48-year-old Chinese man with Stanford type B aortic dissection suffered acute RAD during the TEVAR. And palliative stent grafts placement was performed in a local hospital, which earned the time for transfer and subsequent total arch replacement surgery in Zhongshan Hospital Fudan University. This report suggests that the palliative strategy may be an option for RAD in some specific situation. PMID:25590002

  14. Palliative stent graft placement combined with subsequent open surgery for retrograde ascending dissection intra-thoracic endovascular aortic repair.

    Science.gov (United States)

    Zhu, Kai; Lai, Hao; Guo, Changfa; Li, Jun; Wang, Chunsheng

    2014-12-01

    Thoracic endovascular aortic repair (TEVAR) is an effective strategy for type B dissection. Retrograde ascending dissection (RAD) intra-TEVAR is a rare complication on clinic. In this case, a 48-year-old Chinese man with Stanford type B aortic dissection suffered acute RAD during the TEVAR. And palliative stent grafts placement was performed in a local hospital, which earned the time for transfer and subsequent total arch replacement surgery in Zhongshan Hospital Fudan University. This report suggests that the palliative strategy may be an option for RAD in some specific situation.

  15. Coil Migration through a Neuroform 3 Stent during Endovascular Coiling. A Case Report.

    LENUS (Irish Health Repository)

    O'Hare, A

    2009-07-29

    Summary: A 43-year-old woman attended for stent assisted coiling. A Neuroform 30 x 4.5 mm stent had been successfully placed over the left periophthalmic aneurysm. During the coiling the first coil migrated through the crowns in the stent, lodging at the MCA bifurcation. We believe that the coil herniated through the overlying stent due to the carotid siphon curvature and the open cell design. Furthermore the distal markers of the stent impeded coil extraction with a MERCI device.

  16. Catheter fixation and ligation: a simple technique for ventriculostomy management following endovascular stenting.

    Science.gov (United States)

    Sweeney, Justin M; Vasan, Rohit; van Loveren, Harry R; Youssef, A Samy; Agazzi, Siviero

    2013-05-01

    The object of this study was to describe a unique method of managing ventriculostomy catheters in patients on antithrombotic therapy following endovascular treatment of ruptured intracranial aneurysms. The authors retrospectively reviewed 3 cases in which a unique method of ventriculostomy management was used to successfully avoid catheter-related hemorrhage while the patient was on dual antiplatelet therapy. In this setting, ventriculostomy catheters are left in place and fixed to the calvarium with titanium straps effectively ligating them. The catheter is divided and the distal end is removed. The proximal end can be directly connected to a distal shunt system during this stage or at a later date if necessary. The method described in this report provided a variety of management options for patients requiring external ventricular drainage for subarachnoid hemorrhage. No patient suffered catheter-related hemorrhage. This preliminary report demonstrates a safe and effective method for discontinuing external ventricular drainage and/or placing a ventriculoperitoneal shunt in the setting of active coagulopathy or antithrombotic therapy. The technique avoids both the risk of hemorrhage related to catheter removal and reinsertion and the thromboembolic risks associated with the reversal of antithrombotic therapy. Some aneurysm centers have avoided the use of stent-assisted coiling in cases of ruptured aneurysms to circumvent ventriculostomy-related complications; however, the method described herein should allow continued use of this important treatment option in ruptured aneurysm cases. Further investigation in a larger cohort with long-term follow-up is necessary to define the associated risks of infection using this method.

  17. Combined application of distal and proximal embolic protection devices in endovascular stenting for severe carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Zhi-hua DU

    2011-09-01

    Full Text Available Objective To analyze and summarize methods and experiences of combined application of distal and proximal embolic protection devices(EPD in endovascular stenting for severe carotid artery stenosis.Methods Five patients with severe stenosis of the common carotid artery or with extracranial segment of the internal carotid artery diagnosed through digital subtraction angiography(DSA from March to July 2010 were involved in the present study.All patients received carotid angioplasty and stenting(CAS,with a combination of distal and proximal EPD via the percutaneous femoral artery approach.Results The operation failed in one patient,whereas technical success with no intraoperative complication was achieved in four patients.The symptoms disappeared or improved in the four cases that achieved technical success.The follow-up duration was one to three months,and no cerebral ischemia was found.Conclusion CAS with the combined application of distal and proximal EPD in some special cases of carotid artery stenosis may surmount the shortage of single EPD,reduce the risk of intraoperative embolization,decrease the time of intraoperative endovascular inflow occlusion,and reduce high-risk operations.CAS may be used as an individualized treatment strategy for patients with carotid artery stenosis.

  18. Physiologically-relevant measurements of flow through coils and stents: towards improved modeling of endovascular treatment of intracranial aneurysms

    Science.gov (United States)

    Barbour, Michael; Levitt, Michael; Geindreau, Christian; Rolland Du Roscoat, Sabine; Johnson, Luke; Chivukula, Keshav; Aliseda, Alberto

    2016-11-01

    The hemodynamic environment in cerebral aneurysms undergoing flow-diverting stent (FDS) or coil embolization treatment plays a critical role in long-term outcomes. Standard modeling approaches to endovascular coils and FDS simplify the complex geometry into a homogenous porous volume or surface through the addition of a Darcy-Brinkman pressure loss term in the momentum equation. The inertial and viscous loss coefficients are typically derived from published in vitro studies of pressure loss across FDS and coils placed in a straight tube, where the only fluid path is across the treatment - an unrealistic representation of treatment apposition in vivo. The pressure drop across FDS and coils in side branch aneurysms located on curved parent vessels is measured. Using PIV, the velocity at the aneurysm neck plane is reconstructed and used to determine loss coefficients for better models of endovascular coils or FDS that account for physiological placement and vessel curvature. These improved models are incorporated into CFD simulations and validated against in vitro model PIV velocity, as well as compared to microCT-based coil/stent-resolving CFD simulations of patient-specific treated aneurysm flow.

  19. An Unusual Case of Stent Migration After Celiac Trunk Endovascular Revascularization

    Energy Technology Data Exchange (ETDEWEB)

    Negri, Silvia; Ferraro, Stefania; Piffaretti, Gabriele, E-mail: gabriele.piffaretti@uninsubria.it; Rivolta, Nicola; Bossi, Matteo [University of Insubria School of Medicine, Vascular Surgery, Department of Surgical Sciences, Circolo University Hospital (Italy); Carrafiello, Gianpaolo [University of Insubria School of Medicine, Interventional Radiology, Department of Radiology, Circolo University Hospital (Italy); Castelli, Patrizio [University of Insubria School of Medicine, Vascular Surgery, Department of Surgical Sciences, Circolo University Hospital (Italy)

    2012-08-15

    A 61-year-old woman underwent celiac trunk stenting to treat abdominal angina. Three months later, she was readmitted for recurrent symptoms. Computed tomography control revealed the migration of the stent into the splenic artery. No sign of vessel injury or end-organ ischemia was detected. Repeat stenting of the celiac trunk was performed; the postoperative course was uneventful. 12 months later, the patient was asymptomatic with the second stent in its correct position, and she was asymptomatic for mesenteric ischemia.

  20. Endovascular rescue from arterial rupture and thrombosis during middle cerebral artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, J.Y.; Chung, Y.S. [Department of Neurosurgery, College of Medicine, Pundang CHA Hospital, 351 Yatap-ding, Pundang-gu, 463-712, Sungnam (Korea); Lee, B.H. [Department of Interventional Neuroradiology, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea); Kim, O.J. [Department of Emergency Medicine, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea)

    2003-08-01

    Intravascular stents are being used with increasing frequency in interventional neuroradiology. Iatrogenic arterial rupture is an uncommon but serious complication. We present a case of arterial rupture and subarachnoid haemorrhage during middle cerebral artery stenting, treated by emergency additional, overlapping stenting and balloon tamponade of the dissected vessel. Thrombotic occlusion of the artery was managed by intra-arterial abciximab. Normal vessel patency was re-established within 20 min and the patient recovered with no neurological deficit. (orig.)

  1. The use of intravascular ultrasound as control procedure for the deployment of endovascular stented grafts

    DEFF Research Database (Denmark)

    Vogt, K C; Brunkwall, J; Malina, M;

    1997-01-01

    from guidewires or the introducer system. Imaging during stent deployment was abandoned after IVUS catheter damage in two of three cases. Postprocedural IVUS was able to evaluate the expansion of the stents and the adaptation to the aortic wall in all instances. In four (29%) cases a leak...... was identified. Additional intervention included deployment of a further stent (n = 2) or redilation (n = 2). Covering of the renal arteries could only be indirectly determined by IVUS. CONCLUSION: IVUS can provide important decisive information before and after stented graft deployment, with the limitations...

  2. LOW-DOSE RADIOACTIVE ENDOVASCULAR STENTS PREVENT NEOINTIMAL HYPERPLASIA IN RABBITS RESTENOSIS MODEL

    Institute of Scientific and Technical Information of China (English)

    任晓庆; 黄定九; 黄刚; 毛家亮

    2002-01-01

    Objective To evaluate the effects of low-dose radioactive stents on the prevention of restenosis in rabbit model. Methods The stents were bombarded with suitable charged particles of adapted energy in the cyclotron to create a proper mixture of the radionuclides 59Fe, 60Co, 58Co, 51Cr, and 54Mn. The radioactive stents were implanted in the iliac arteries of rabbits. The effects of radioactive stents on prevention of restenosis were assessed by angiography, histomorphometry and immunocytochemistry. Results All the iliac arteries that had been implanted with radioactive stents were patent on angiography and had no radiation complication during the 1~2 months of follow-up. There was a significant reduction in neointimal area (0.37±0.14mm2 vs. 0.81±0.10mm2, P<0.01), percent area stenosis (6.7±2.9% vs. 13.2±1.4%, P<0.01) and PCNA immunoreactive rate (2.00±1.58% vs. 10.88±6.98%, P<0.05) in the radioactive stent group compared with the control stent group. Conclusion Radioactive stents with an active of 0.91~1.65 μCi could inhibit SMC proliferation and neointimal hyperplasia in animal restenosis model. The low-dose radioactive stents are safe and feasible for prevention of restenosis.

  3. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents.

    Science.gov (United States)

    Grimme, Frederike A B; Spithoven, J Hans; Zeebregts, Clark J; Scharn, Dirk M; Reijnen, Michel M P J

    2015-09-01

    To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. The study included 69 consecutive patients (29 men, 40 women) who underwent kissing stent procedures with CBESs between January 2003 and April 2009 in a single center. Patients who were previously treated with a CBES were excluded. Follow-up consisted of clinical investigation and duplex ultrasound examination. The primary patency was 88.1% at 1 year and 71.5% at 4 years, with secondary patency rates of 88.1% and 75.3%, respectively. For patients receiving a stent for the first time, primary patency was 91.3% at 1 year and 77.1% at 4 years. For patients who had received previous stents, patency was 83.6% at 1 year and 65.2% at 4 years (P = .83). There were no differences in secondary patency and freedom from target lesion reintervention (TLR). Loss of primary patency was mainly caused by stent occlusions (14 cases [78%]). The freedom from TLR at 4 years was 76.8%. Patency rates and freedom from TLR of CBESs in the kissing stent configuration with up to 4 years of follow-up were satisfying and mainly affected by stent occlusions. Studies focusing on optimizing stent configuration and medical care to reduce the incidence of thrombosis are indicated to improve results further. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  4. Subclavian artery pseudoaneurysm complicating central venous catheterization: endovascular treatment with Amplatzer Vascular Plug 4 and covered stent.

    Science.gov (United States)

    Rossi, Umberto G; Petrocelli, Francesco; Ferro, Carlo

    2013-12-01

    Central venous catheterization is a routine vascular access procedure; however, it may be associated with life-threatening complications such as arterial puncture, leading to pseudoaneurysm formation. We report a case of a 41-year-old female that developed an iatrogenic left subclavian pseudoaneurysm complicating the attempt of left internal jugular vein cannulation for temporary hemodialysis therapy. The patient underwent urgent endovascular treatment with deployment of covered stent into the left subclavian artery (SCA) after embolization of the origin of the left internal mammary artery with Amplatzer Vascular Plug 4. The patient's recovery was unremarkable. Follow-up till 24 months reveals total exclusion of the pseudoaneurysm of the left SCA with patency of the distal branches.

  5. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    NARCIS (Netherlands)

    Grimme, Frederike A. B.; Spithoven, J. Hans; Zeebregts, Clark J.; Scharn, Dirk M.; Reijnen, Michel M. P. J.

    Purpose: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. Materials and Methods: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing

  6. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    NARCIS (Netherlands)

    Grimme, F.A.B.; Spithoven, J.H.; Zeebregts, C.J.A.; Scharn, D.M.; Reijnen, M.M.

    2015-01-01

    PURPOSE: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. MATERIALS AND METHODS: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing

  7. The use of fenestrated and branched endovascular aneurysm repair for juxtarenal and thoracoabdominal aneurysms: A systematic review and cost-effectiveness analysis

    NARCIS (Netherlands)

    N. Armstrong (Nigel); L.T. Burgers (Laura); S. Deshpande (Sohan); M.J. Al (Maiwenn); R. Riemsma; S.R. Vallabhaneni; P. Holt (Peter); J.L. Severens (Hans); J. Kleijnen (Jos)

    2015-01-01

    textabstractBackground: Patients with large abdominal aortic aneurysms (AAAs) are usually offered reparative treatment given the high mortality risk. There is uncertainty about how to treat juxtarenal AAAs (JRAAAs) or thoracoabdominal aortic aneurysms (TAAAs). Endovascular repair of an abdominal aor

  8. The use of fenestrated and branched endovascular aneurysm repair for juxtarenal and thoracoabdominal aneurysms: A systematic review and cost-effectiveness analysis

    NARCIS (Netherlands)

    N. Armstrong (Nigel); L.T. Burgers (Laura); S. Deshpande (Sohan); M.J. Al (Maiwenn); R. Riemsma; S.R. Vallabhaneni; P. Holt (Peter); J.L. Severens (Hans); J. Kleijnen (Jos)

    2015-01-01

    textabstractBackground: Patients with large abdominal aortic aneurysms (AAAs) are usually offered reparative treatment given the high mortality risk. There is uncertainty about how to treat juxtarenal AAAs (JRAAAs) or thoracoabdominal aortic aneurysms (TAAAs). Endovascular repair of an abdominal aor

  9. Endovascular repair of bilateral common iliac artery aneurysms using GORE Excluder iliac branch endoprosthesis without aortobi-iliac stent graft conjunction: A case report.

    Science.gov (United States)

    Ardita, Vincenzo; Giaquinta, Alessia; Veroux, Massimiliano; Sanfiorenzo, Angelo; Virgilio, Carla; D'Arrigo, Giuseppe; Veroux, Pierfrancesco

    2017-02-01

    Bilateral common iliac artery (CIA) aneurysm (CIAA) is a rare entity. In the past decade, different endovascular approaches have been adopted for patients with several comorbidities or unfit for open repair (OR). Recently, the use of iliac branch stent graft has been proposed, resulting in satisfactory patency rates and decrease in morbidity. Currently, according to instruction for use, the iliac branch stent graft is to be used with aortobi-iliac stent graft conjunction. We describe a case of a successful endovascular repair of bilateral CIAAs using the GORE Excluder iliac branch endoprosthesis (IBEs) without aortobi-iliac stent graft conjunction. An 83-year-old man was admitted with abdominal pain and presence of pulsatile mass in the right and left iliac fossa. Computed tomographic (CT) angiography showed the presence of large bilateral CIAAs (right CIA = 66 mm; left CIA = 38 mm), without concomitant thoracic or abdominal aorta aneurysm. Moreover, CT scan demonstrated the presence of bilateral lower accessory renal artery close to the aortic bifurcation. Due to the high operative risk, the patient was scheduled for endovascular repair with bilateral IBEs, without the aortobi-iliac stent graft conjunction to avoid the renal ischemia as a consequence of renal arteries covering. The procedure was completed without complications and duplex ultrasound demonstrated the complete exclusion of both aneurysms without any type of endoleaks at 1 month of follow-up. GORE IBEs without aortobi-iliac stent graft conjunction seem to be a feasible and effective procedure for the treatment of isolated CIAAs in patients with highly selected anatomical conditions.

  10. Endovascular Management of Aorta-Iliac Stenosis and Occlusive Disease by Kissing-Stent Technique.

    Science.gov (United States)

    Liu, Meng; Zhang, Fuxian

    2016-01-01

    Kissing-stenting treatment has been used to treat patients with peripheral artery disease (PAD). However, the long term efficacy of the stenting therapy is not well defined in Chinese PAD patients. To investigate the question, sixty-three PAD patients (37 males and 26 females), aged 66 ± 7.3 years, were analysed in the study. They were featured as claudication (n = 45, 71.4%), rest pain (n = 18, 28.6%), or gangrene (n = 8, 12.7%). In total, 161 stents were applied in aorta-iliac lesions with 2.6 stents for each patient, including 55 self-expanding stents, 98 balloon expandable stents, and 8 covered stents. The success rate of implanting Kissing-stents was 100%. Catheter-directed thrombolysis (CDT) with urokinase was performed in 8 cases (12.7%). The severity of peripheral ischemia was significantly improved, as evidenced by 3.3-fold increase of ankle-brachial pressure index (ABI) after the surgery (P = 0.008). One, three, five, and seven years after surgery, the primary patency rate was 87.3%, 77.4%, 71.1%, and 65.0%, whereas the secondary patency rate was 95.2%, 92.5%, 89.5%, and 85.0%, respectively. No in-hospital mortality was recorded. In conclusion, Kissing-stenting technique for aorta-iliac lesions is safe and effective with lower complications. It is beneficial for aorta-iliac occlusions that are longer than 60 mm.

  11. Endovascular Management of Aorta-Iliac Stenosis and Occlusive Disease by Kissing-Stent Technique

    Directory of Open Access Journals (Sweden)

    Meng Liu

    2016-01-01

    Full Text Available Kissing-stenting treatment has been used to treat patients with peripheral artery disease (PAD. However, the long term efficacy of the stenting therapy is not well defined in Chinese PAD patients. To investigate the question, sixty-three PAD patients (37 males and 26 females, aged 66±7.3 years, were analysed in the study. They were featured as claudication (n=45, 71.4%, rest pain (n=18, 28.6%, or gangrene (n=8, 12.7%. In total, 161 stents were applied in aorta-iliac lesions with 2.6 stents for each patient, including 55 self-expanding stents, 98 balloon expandable stents, and 8 covered stents. The success rate of implanting Kissing-stents was 100%. Catheter-directed thrombolysis (CDT with urokinase was performed in 8 cases (12.7%. The severity of peripheral ischemia was significantly improved, as evidenced by 3.3-fold increase of ankle-brachial pressure index (ABI after the surgery (P=0.008. One, three, five, and seven years after surgery, the primary patency rate was 87.3%, 77.4%, 71.1%, and 65.0%, whereas the secondary patency rate was 95.2%, 92.5%, 89.5%, and 85.0%, respectively. No in-hospital mortality was recorded. In conclusion, Kissing-stenting technique for aorta-iliac lesions is safe and effective with lower complications. It is beneficial for aorta-iliac occlusions that are longer than 60 mm.

  12. Successful endovascular treatment of a growing megadolichoectasic vertebrobasilar artery aneurysm by flow diversion using the "diverter-in-stent" technique.

    Science.gov (United States)

    Cohen, José E; Gomori, John M; Moscovici, Samuel; Itshayek, Eyal

    2012-01-01

    Giant dolichoectatic and fusiform aneurysms of the vertebrobasilar artery are among the most difficult and dangerous aneurysms to treat. Conservative management may be reasonable in asymptomatic elderly patients. Nevertheless, due to the frequent presence of mass effect on the brainstem and the risks of thromboembolic events and rupture, these aneurysms often demand treatment rather than observation. With the advancement of endovascular techniques some of these lesions have become treatable without the high morbidity and mortality rates associated with open surgical treatment. When dealing with giant, progressively enlarging symptomatic aneurysms, more limited therapeutic alternatives are available. The authors present a case of a growing megadolichoectatic vertebrobasilar artery aneurysm causing major disability due to increasing mass effect in a 51-year-old man. The aneurysm was treated with flow diversion by placing multiple telescoped stents and diverters ("diverter-in-stent" technique), achieving thrombosis of the aneurysm and reduction of the mass effect on the brainstem, with neurological improvement. The successful clinical and angiographic results observed in our case of giant dolichoectasic vertebrobasilar aneurysm contribute to the literature on giant aneurysms treated by means of flow diversion. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Endovascular treatment of ruptured abdominal aortic aneurysm with aortocaval fistula based on aortic and inferior vena cava stent-graft placement.

    Science.gov (United States)

    Silveira, Pierre Galvagni; Cunha, Josué Rafael Ferreira; Lima, Guilherme Baumgardt Barbosa; Franklin, Rafael Narciso; Bortoluzzi, Cristiano Torres; Galego, Gilberto do Nascimento

    2014-11-01

    A ruptured abdominal aortic aneurysm (RAAA), complicated by an aortocaval fistula (ACF), is usually associated with high morbidity and mortality during open operative repair. We report a case of endovascular treatment of an RAAA with ACF. After accessing both common femoral arteries, a bifurcated aortic stent graft was placed. Subsequently, we accessed the fistula from the right femoral vein and a cava vein angiography showed a persistent massive flow from the cava to the excluded aneurysm sac. We proceeded by covering the fistula with an Excluder aortic stent-graft cuff to prevent pressurization of the aneurysm sac and secondary endoleaks. This procedure is feasible and may reduce the chances of posterior endoleaks.

  14. Endovascular Mechanical Recanalisation After Intravenous Thrombolysis in Acute Anterior Circulation Stroke: The Impact of a New Temporary Stent

    Energy Technology Data Exchange (ETDEWEB)

    Fesl, Gunther, E-mail: gunther.fesl@med.uni-muenchen.de; Patzig, Maximilian; Holtmannspoetter, Markus [University of Munich, Department of Neuroradiology (Germany); Mayer, Thomas E. [University of Jena, Department of Neuroradiology (Germany); Pfefferkorn, Thomas; Opherk, Christian [University of Munich, Department of Neurology (Germany); Brueckmann, Hartmut [University of Munich, Department of Neuroradiology (Germany); Wiesmann, Martin [University Hospital, Department of Diagnostic and Interventional Neuroradiology (Germany)

    2012-12-15

    Purpose: Treatment of acute stroke by endovascular mechanical recanalisation (EMR) has shown promising results and continues to be further refined. We evaluated the impact of a temporary stent compared with our results using other mechanical devices. Materials and Methods: We analysed clinical and radiological data of all patients who were treated by EMR after intravenous thrombolysis for acute carotid T- and middle-cerebral artery (M1) occlusions at our centre between 2007 and 2011. A comparison was performed between those patients in whom solely the stent-retriever was applied (group S) and those treated with other devices (group C). Results: We identified 14 patients for group S and 16 patients for group C. Mean age, National Institute of Health Stroke Scale score, and time to treatment were 67.1 years and 16.5 and 4.0 h for group S and 61.1 years and 17.6 and 4.5 h for group C, respectively. Successful recanalisation (thrombolysis in cerebral infarction scores {>=}IIb) was achieved in 93% of patients in group S and 56% of patients in group C (P < 0.05). Mean recanalisation times for M1 occlusions were 23 min (group S) and 29 min (group C) and for carotid-T occlusions were 39 min (group S) and 50 min (group C), and 45% of the patients in group S and 33% in group C had a favourable outcome (Modified Rankin Scale score {<=}2). Conclusion: The findings suggest an improvement in recanalisation success by the application of a temporary stent compared with previously used devices. These results are to be confirmed by larger studies.

  15. Emergency rescue endovascular stent grafting of ascending aorta to relieve life-threatening coronary obstruction in a case of acute aortic dissection.

    Science.gov (United States)

    Tauchi, Yuuya; Tanioka, Hideki; Kondoh, Haruhiko; Satoh, Hisashi; Matsuda, Hikaru

    2014-12-01

    Myocardial ischemia associated with acute aortic dissection is frequently a fatal complication, and the emergent management still remains a challenge. We report a patient with life-threatening myocardial ischemia due to acute aortic dissection managed by rescue stent grafting of the ascending aorta. Coronary blood flow improved immediately with this endovascular procedure, hemodynamic status was ameliorated dramatically, followed by uneventful open repair. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Endovascular stenting in superior vena cava syndrome: utility of a through-and-through guidewire technique

    Energy Technology Data Exchange (ETDEWEB)

    Clark, T.W.I. [Dalhousie Univ., Queen Elizabeth II Health Sciences Centre, Section of Interventional Radiology, Dept. of Diagnostic Imaging, Halifax, NS (Canada)

    2000-08-01

    Objective: To describe an ancillary technique when a conventional femoral approach to superior vena cava (SVC) stent placement is not feasible because of buckling of balloon catheters or stent-deployment systems during device advancement. Patients and methods: Three patients in whom device advancement across the SVC lesion from a femoral or axillary approach was unsuccessful were managed by accessing the right jugular vein; SVC lesions were crossed from an antegrade direction, and the jugular guidewire was secured at the femoral access site to create a through-and-through guidewire. Results: Countertraction on the through-and-through guidewire during stent placement and dilation permitted unhindered advancement of stent delivery systems and catheters across the SVC. Technical and clinical success was achieved in each patient with relief of SVC syndrome within 24-72 hours. Survival ranged from 26 to 137 days. Conclusion: A through-and-through guidewire technique is useful when stenting a highly stenotic or thrombosed SVC in patients with superior vena cava syndrome. (author)

  17. Endovascular aneurysm repair utilizing the AneuRx and Talent stent grafts.

    Science.gov (United States)

    Arko, Frank R; Murphy, Erin H

    2008-06-01

    Favorable clinical results combined with increased patient demand for minimally invasive surgery have resulted in an increased application of endovascular aneurysm repair, and this treatment modality is now being extended to younger, healthier patients. While it seems that endovascular aneurysm repair is becoming a desirable option for many patients, it is essential to realize that the feasibility of the procedure may be limited at times by patient anatomy and technical difficulties. Specific anatomical difficulties can be imposed by difficult access, short, tortuous and calcified aortic and iliac landing zones, and the presence of coincident complex iliac aneurysms. This manuscript will discuss the use of 2 approved devices from a single manufacturer (Medtronic, Santa Rosa, Calif) and their clinical results in the treatment of infrarenal abdominal aortic aneurysms. We will discuss technical maneuvers and considerations when encountering difficult anatomical situations and how to avoid long-term complications.

  18. Proximal scalloped custom-made Relay® stent graft in chronic type B dissection: endovascular repair in a drug abuser patient

    Science.gov (United States)

    Szeberin, Zoltán; Nemes, Balázs; Csobay-Novák, Csaba; Mihály, Zsuzsa; Entz, László

    2016-01-01

    The best solution for enlarging chronic type B aortic dissection is not known. Hybrid surgical and endovascular procedures offer a reliable solution in such circumstances, but technically complex stent-graft designs are sometimes needed when the treatment segment of the aorta presents anatomical challenges. We report a case of a proximally scalloped custom-made stent-graft implantation following left subclavian artery transposition in a formerly cocaine-abuser patient. The one-month follow-up computed tomography angiography showed a proximal endoleak (type Ia) which was successfully solved by coil embolization. Proximally scalloped stent grafts offer a reliable solution in complex aortic dissections involving the supra-aortic branches. PMID:28250982

  19. Potential Long-Term Complications of Endovascular Stent Grafting for Blunt Thoracic Aortic Injury

    OpenAIRE

    Miller, Larry E

    2012-01-01

    Blunt thoracic aortic injury (BTAI) is a rare, but lethal, consequence of rapid deceleration events. Most victims of BTAI die at the scene of the accident. Of those who arrive to the hospital alive, expedient aortic intervention significantly improves survival. Thoracic endovascular aortic repair (TEVAR) has been accepted as the standard of care for BTAI at many centers, primarily due to the convincing evidence of lower mortality and morbidity in comparison to open surgery. However, less atte...

  20. Multilayer stents, a new progress in the endovascular treatment of aneurysms

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yong-xue; LU Qing-sheng; JING Zai-ping

    2013-01-01

    Objective To review the recent progress of multilayer stents in treating arterial aneurysms and to draw an initial conclusion about its paradigm.Data sources PubMed database and ELSEVIER database were searched with the keywords "cardiatis" or "multilayer stent" for relevant articles from January 2008 to September 2012.Relevant websites (provided by Cardiatis) were also involved in the review process.Study selection Well-controlled,relatively large-scale,retrospective studies as well as meaningful individual cases were all selected as materials.Results A total of 23 articles were involved in this review.The newly introduced Cardiatis multilayer stent aims at creating an active flow-modulating barrier between normal blood flow and aneurismal sac,which can induce thrombosis within aneurismal sac and preserve collateral circulation at the same time.Currently,it has been applied for complicated aneurysms located in different segments of the arterial system.Conclusion This new concept of multilayer uncovered stent offers a promising alterative in the treatment of arterial aneurysms.However,a further large-scale clinical and hemodynamic study is required to evaluate the long-term effects.

  1. Spontaneous rupture of the left common iliac vein: management with surgical repair and endovascular stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hwan; Lee, Sang Kwon; Ko, Sung Min; Choi, Jin Soo; Koo, Ja Hyun; Kim, Hyung Tae; Cho, Won Hyun [Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2006-06-15

    We report here on a case of spontaneous rupture of the left common iliac vein that was diagnosed preoperatively with computed tomography (CT), and the patient was successfully treated with surgery and stent placement. A 60-year-old woman was referred to our emergency room because of sudden left lower abdominal pain and swelling of the left lower extremity. CT revealed a huge retroperitoneal hematoma and extrinsic compression of the left common iliac vein with acute thrombosis of the deep veins of the left lower extremity. Venous patch angioplasty was performed at the site of spontaneous rupture. After performing thrombectomy with using a Forgaty catheter, a stent was placed at the occluded segment of the left common iliac vein under C-arm fluoroscopic guidance. The follow-up CT scans taken at 10 days and 8 months after the initial examination demonstrated a venous stent with preserved luminal patency and the striking resolution of the deep vein thrombosis of the left lower extremity.

  2. Physician modification of Gore C3 excluder endograft for treatment of abdominal aortic aneurysms anatomically unsuitable for conventional endovascular repair.

    Science.gov (United States)

    Coulter, Amy H; Tan, Tze-Woei; Zhang, Wayne W

    2014-06-01

    Until recently, the Cook Zenith aortic endograft (Cook Medical Inc, Bloomington, Ind) was the only device used for physician-modified fenestration because its constraining wire allowed physicians to reconstrain the device after modifications. Although the Cook Zenith fenestrated endograft has been approved by the Food and Drug Administration, it is currently not available in the majority of the hospitals and is not applicable to the patients who need urgent or emergent aneurysm repair. With the redesign of the Gore C3 delivery system, the Gore Excluder aortic stent graft (W. L. Gore & Associates, Inc, Flagstaff, Ariz) can now also be reconstrained, which makes it suitable for physician-modified fenestration. We describe the technique for modification and implantation of the Gore Excluder aortic stent graft in a patient requiring 2-vessel bilateral renal artery fenestration. This application provides an additional option for treatment of patients with abdominal aortic aneurysms who are anatomically unsuitable for conventional endovascular aneurysm repair and are at high risk for open repair. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  3. Technical concepts for vascular electromagnetic navigated interventions: aortic in situ fenestration and transjugular intrahepatic porto-systemic shunts.

    Science.gov (United States)

    Penzkofer, Tobias; Isfort, Peter; Na, Hong-Sik; Wilkmann, Christoph; Osterhues, Sabine; Besting, Andreas; Hänisch, Christoph; Bisplinghoff, Stefan; Jansing, Johannes; von Werder, Sylvie; Gooding, Jorge; de la Fuente, Mathias; Mahnken, Andreas H; Disselhorst-Klug, Catherine; Schmitz-Rode, Thomas; Kuhl, Christiane K; Bruners, Philipp

    2014-04-01

    This work presents concepts for complex endovascular procedures using electromagnetic navigation technology (EMT). Navigation software interfacing a standard commercially available navigation system was developed, featuring registration, electromagnetic field distortion correction, breathing motion detection and gating, and state-of-the-art 3D imaging post processing. Protocols for endovascularly placed, in-situ fenestrated abdominal aortic stent grafts and an EMT guided transjugular intrahepatic portosystemic shunt (TIPSS) creation have been designed. A dedicated set of interventional devices was developed for each of the procedures: For aortic in-situ fenestration a combination of high-porosity stentgrafts, steerable catheters and electromagnetically navigated guidewires was used, for TIPSS a dual-navigated (sheath and stylet) TIPSS-device was designed and manufactured. The developed devices underwent phantom testing, in preparation for animal experiments to prove the feasibility of the approach. Once established, these systems could aid in performing these challenging interventional radiology procedures, exploiting the unique characteristics of electromagnetic navigation and solving multiple of the problems associated with these interventions being performed under X-ray fluoroscopy, such as lacking real-time 3D information or extensive exposure to ionizing radiation.

  4. Three-year-old child with middle aortic syndrome treated by endovascular stent implantation.

    Science.gov (United States)

    Moszura, Tomasz; Goreczny, Sebastian; Dryzek, Pawel; Niwald, Marek

    2013-04-01

    Middle aortic syndrome (MAS) is an extremely rare anomaly and represents both a diagnostic and therapeutic challenge, particularly in young children. A case of a 3.5 year-old child with MAS and arterial hypertension is reported, where owing to the patient's young age and the length of the hypoplastic aortic segment, surgical correction with end-to-end anastomosis was not feasible. Instead of palliative bypass grafting between the thoracic and abdominal aorta, successful percutaneous balloon angioplasty and stenting of the lesion was performed with the assistance of three-dimensional rotational angiography.

  5. Endovascular stenting of the transverse sinus in a patient presenting with benign intracranial hypertension.

    Science.gov (United States)

    Ogungbo, B; Roy, D; Gholkar, A; Mendelow, A D

    2003-12-01

    The authors present a 37-year-old lady with symptoms and signs suggestive of benign intracranial hypertension (BIH). Routine CT and MRI scans were normal. Further investigations were performed with magnetic resonance venography (MRV) and cerebral venography. These revealed obstruction of the right transverse sinus with high pressure (40 mmHg) proximal to the obstruction and low pressure (15 mmHg) distally. She was treated by transvenous stent deployment with resolution of her symptoms and the bilateral papilloedema. Evaluation of the cerebral venous system with MRV and or with formal cerebral venography should be included in routine investigations of patients with suspected BIH.

  6. Implanted central venous catheter-related acute superior vena cava syndrome: management by metallic stent and endovascular repositioning of the catheter tip

    Energy Technology Data Exchange (ETDEWEB)

    Qanadli, S.D.; Mesurolle, B.; Sissakian, J.F.; Chagnon, S.; Lacombe, P. [Service de Radiologie, Hopital Ambroise Pare, 92 - Boulogne (France)

    2000-08-01

    We describe a case of a 49-year-old woman with stage-IIIB lung adenocarcinoma who experienced an acute superior vena cava syndrome related to an implanted central venous catheter without associated venous thrombosis. The catheter was surgically implanted for chemotherapy. Superior vena cava syndrome appeared after the procedure and was due to insertion of the catheter through a subclinical stenosis of the superior vena cava. Complete resolution of the patient's symptoms was obtained using stent placement and endovascular repositioning of the catheter tip. (orig.)

  7. Endovascular stent for coarctation of the aorta in a child and review of the literature.

    Science.gov (United States)

    Cheng, Hsu-Ting; Lin, Ming-Chih; Jan, Sheng-Ling; Fu, Yun-Ching

    2011-08-01

    An 11-year-old, 35-kg boy underwent balloon angioplasty twice, at the ages of 4 years and 10 years, with only limited effect. He was admitted for another cardiac catheterization because of chest pain and breathlessness on exercise. Aortography revealed severe discrete coarctation of the aorta, with the narrowest diameter of 6mm. The pressures of the ascending aorta and descending aorta were 115/72mmHg and 93/66mmHg, respectively. After implantation of a 16-mm-diameter stent, the systolic pressure gradient decreased from 22mmHg to 0mmHg. Annual follow-up for 6 years showed normal blood pressure, no exercise intolerance, and no recoarctation.

  8. Fenestration of a Papyrus PK covered stent to recover the occluded left main bifurcation after sealing a left main perforation during a CTO procedure.

    Science.gov (United States)

    Werner, Gerald S; Ahmed, Waqar H

    2017-03-06

    Covered stents are indicated for coronary perforations, but they may seal off major side branches in that process. We report the successful sealing of an ostial left main perforation, induced by a guide catheter in the course of a retrograde approach to treat a chronic total occlusion (CTO) of the right coronary artery (RCA) in a 76year old woman with prior CABG. The implanted Papyrus covered stent, however, overlapped the left main bifurcation and occluded the non-grafted circumflex artery (CX) resulting in acute ischemia. Through a double lumen catheter advanced over the wire located in the left anterior descending coronary artery (LAD) territory, a stiff recanalization wire could be advanced from the side-port to penetrate the stent membrane towards the CX. This was successfully achieved, and after subsequent dilatation, a drug-eluting stent was implanted in Culotte-fashion from the CX to the left main with subsequent kissing-balloon dilatation. The clinical symptoms subsided immediately, and the RCA was finally recanalized in antegrade parallel wire technique. No periprocedural infarct was observed during 48h of follow-up before discharge. At clinical follow-up of 6months the patient is symptom-free. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. 血管内支架治疗椎动脉梭形动脉瘤%Endovascular treatment of fusiform aneurysms of vertebral artery using stents

    Institute of Scientific and Technical Information of China (English)

    孟凡国; 于建军; 费昶

    2009-01-01

    目的 探讨血管内支架治疗颅内椎动脉梭形动脉瘤的临床效果.方法 回顾血管内支架治疗的23例椎动脉瘤患者(12例破裂,11例未破裂).临床结果进行GOS评分.结果 23例发现24个椎动脉梭形动脉瘤,共放置了25个支架.所有支架均成功释放,19例用弹簧圈栓塞动脉瘤,3例只放置了支架,1例放置了2枚Neuroform支架来覆盖瘤颈.没有发生与操作技术相关的并发症.临床随访22例(96%)恢复良好(GOS=5),1例(4%)由于术中动脉瘤破裂出血而死亡(GOS=1).结论 血管内应用支架是治疗累及小脑后下动脉上、对侧椎动脉发育不好或未破裂的椎动脉梭形动脉瘤的一种有效的治疗方法.%Objective To report clinical outcomes of endovascular treatment of fusiform aneurysms of vertebral artery (VA) using stents. Methods Consecutive 23 cases (12 ruptured, 11 unruptured) of vertebral artery fusiform aneurysms treated with stents were retrospectively reviewed. Their clinical outcomes were graded with Glasgow outcome scale. Results Twenty-five stents were placed in 23 patients for 24 fusiform VA aneurysms. All patients were successfully treated using stents. In 19 patients coil-embolization of the aneurysmal lumen was used. One aneurysm was treated by placement of 2 stents covering the dissection site. There was no technique-related complication. According to the Glasgow Outcome Scale (GOS), 22 patients (96 %) had a good recovery and 1 (4 %) died due to intraoperative rebleeding. Conclusion Endovascular therapy using stents may be a useful treatment in patients with fusiform VA aneurysms involving the PICA or hypoplasia of the eontralateral VA or unruptured VA aneurysms.

  10. Experiment of new compliance covered endovascular stent in sheep model%新型高柔顺主动脉覆膜支架实验研究

    Institute of Scientific and Technical Information of China (English)

    王韧; 韩晓峰; 杨帆; 孙立忠; 黄连军; 徐志伟; 杜月河; 贾莲; 郑斯宏

    2014-01-01

    目的 探讨新型高柔顺主动脉覆膜支架在动物模型中使用的安全性和可靠性.方法 12只绵羊分为2组,每组6只,分别进行胸主动脉覆膜支架实验和腹主动脉覆膜支架实验.10 mm人工血管与绵羊腹主动脉吻合,然后经人工血管植入输送器和支架,在胸主动脉释放支架.存活30d后行胸主动脉造影,观察支架位置、形态;然后处死绵羊,进行大体解剖和病理检查.结果 所有支架均释放在所需位置,术中造影无支架移位及内漏.胸主动脉支架组有1只羊术后无法站立,术后5d死亡,尸体解剖可见支架部位血管腔内血栓形成,堵塞管腔.腹主动脉支架组有1只羊术后无法站立,术后30 d后处死,尸体解剖同样发现支架部位血管腔内血栓形成,堵塞管腔.其余羊均术后即可站立,正常活动,饮食无异常.1个月后造影,支架部位管腔通畅,支架固定在释放位置,无移位、内漏及造影剂外漏.病理检查结果证实:植入的支架与血管结合紧密,支架内壁组织光滑.结论 新型高柔顺主动脉覆膜支架在动物实验中表现了良好性能,具有安全性和可靠性.%Objective In order to test feasibility and security of new compliance covered endovascular stent in sheep model.Methods 12 sheeps were divided into 2 groups:thoracic aortic stent group and abdominal aortic stent group.10 mm diameters of vascular prosthesis was end-to-side anastomosed with abdominal aorta of the sheep.Stents were transported through vascular prosthesis into thoracic aorta of the sheep.The stents were deployed in desired position of thoracic aorta.30 days later,aortogram were performed to observe position and shape of the stents.Then,the sheep were euthanized,gross and histopathologic study were executed.Results All stent were successfully deployed,no stent shifting and endoleak were observed during aortagram 30 days after operation.1 sheep died of thrombosis of the thoracic aortic stent at 5 day

  11. Endovascular treatment with angioplasty or stenting versus endarterectomy in patients with carotid artery stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomised trial.

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2009-10-01

    Endovascular treatment (angioplasty with or without stenting) is an alternative to carotid endarterectomy for carotid artery stenosis but there are scarce long-term efficacy data showing that it prevents stroke. We therefore report the long-term results of the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS).

  12. Placement of Endovascular Stent across the Branching Arteries: Long-term Serial Evaluation of Stent-tissue Responses Overlying the Arterial Orifices in an Experimental Study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Il; Chung, Jin Wook, E-mail: chungjw@snu.ac.kr [Seoul National University College of Medicine, Department of Radiology (Korea, Republic of); Kim, Hyun Beom [National Cancer Center of Korea, Department of Radiology and Center for Liver Cancer, Research Institute and Hospital (Korea, Republic of); Park, Jae Hyung [Seoul National University College of Medicine, Department of Radiology (Korea, Republic of); Seo, Jeong Wook [Seoul National University College of Medicine, Department of Pathology (Korea, Republic of); Kim, Hyo-Cheol; Jae, Hwan Jun; Lee, Whal [Seoul National University College of Medicine, Department of Radiology (Korea, Republic of)

    2012-10-15

    PurposeThis study was designed to investigate the effects of stenting across the branching arteries on the patency and stent-tissue responses over the branching arterial orifices. Methods: Thirteen dogs were observed after placing aortic stents across the celiac arteries (CA), superior mesenteric arteries (SMA), and renal arteries (RA). The animals were grouped according to stent types: large-cell group (n = 6) and small-cell group (n = 7). Angiography was performed to evaluate the branching artery patency at 2, 6, and 12 months after stent insertion, and the stent-tissue responses covering the orifices were evaluated on histopathologic examination. Results: All branching arteries were patent on follow-up angiography; however, three patterns of stent-tissue responses over the orifices were observed: neointimal layering, bridging septa, and papillary hyperplasia. Although neointimal layering and bridging septa were evenly observed, severe papillary hyperplasia was more frequent at SMA and CA than RA. Four RA showed less than 50% ostial patency, and localized infarct was observed in six kidneys (24%). The ostial patency tended to decrease with small-cell stent during the follow-up period. Conclusions: Various stent-tissue responses over the branching artery orifices are induced by the aortic stent covering the branching arteries and may not be easily detected by conventional angiography. Subclinical renal infarct also may occur despite patent renal angiography.

  13. Late endovascular removal of Günther-Tulip inferior vena cava filter and stent reconstruction of chronic post-thrombotic iliocaval obstruction after 4753 days of filter dwell time: a case report with review of literature.

    Science.gov (United States)

    Doshi, Mehul Harshad; Narayanan, Govindarajan

    2016-12-01

    Chronic post-thrombotic obstruction of the inferior vena cava (IVC) or iliocaval junction is an uncommon complication of long indwelling IVC filter. When such an obstruction is symptomatic, endovascular treatment options include stent placement with or without filter retrieval. Filter retrieval becomes increasingly difficult with longer dwell times. We present a case of symptomatic post-thrombotic obstruction of the iliocaval junction related to Günther-Tulip IVC filter (Cook Medical Inc, Bloomington, IN) with dwell time of 4753 days, treated successfully with endovascular filter removal and stent reconstruction. Filter retrieval and stent reconstruction may be a treatment option in symptomatic patients with filter-related chronic IVC or iliocaval junction obstruction, even after prolonged dwell time.

  14. Tratamento do aneurisma da aorta toracoabdominal com endoprótese ramificada para as artérias viscerais Branched endovascular stent graft for thoracoabdominal aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    André Simi

    2007-03-01

    Full Text Available Apresentamos um caso de aneurisma da aorta toracoabdominal (AATA tratado, exclusivamente, pela técnica endovascular, utilizando uma endoprótese ramificada e customizada. Paciente do sexo feminino, 68 anos de idade, tabagista, hipertensa, portadora de extenso AATA e múltiplas comorbidades que restringiam a indicação de cirurgia convencional. O aneurisma iniciava-se na aorta torácica descendente, estendendo-se até a aorta abdominal infra-renal, envolvendo as emergências das artérias viscerais, tronco celíaco, artérias mesentérica superior e renais. O AATA foi tratado pela técnica endovascular com implante de uma endoprótese ramificada. Essa endoprótese ramificada foi customizada com base nas características anatômicas da aorta e no posicionamento dos ramos viscerais, obtidos em angiotomografia, objetivando excluir o aneurisma, mantendo a perfusão das artérias viscerais. O procedimento foi realizado em centro cirúrgico, sob anestesia combinada, regional e geral, antecedido de drenagem liquórica e sob orientação fluoroscópica. O acesso para o implante do corpo principal da endoprótese ramificada e o controle radiológico foram realizados através das artérias femorais, previamente dissecadas. Através das ramificações da endoprótese, foram implantadas extensões secundárias, com stents revestidos, para as respectivas artérias viscerais, cujo acesso foi realizado via artéria axilar esquerda. O tempo total do procedimento foi de 14 horas, com 4 horas e 30 minutos de fluoroscopia, e foram utilizados 120 mL de contraste iodado. No pós-operatório, a paciente apresentou instabilidade hemodinâmica. Ecocardiograma transesofágico mostrou dissecção retrógrada da aorta torácica, tipo A, seguida de trombose espontânea da falsa luz. A tomografia de controle mostrou exclusão do AATA e perviedade das pontes para os ramos viscerais, sem vazamentos. A alta ocorreu no 13º dia de pós-operatório. O tratamento endovascular do

  15. Endovascular therapy for abdominal aortic aneurysm and iliac artery aneurysm using SEAL aortic stent-graft: A single center experience

    Energy Technology Data Exchange (ETDEWEB)

    Park, Su Young; Kim, Jeong Ho; Byun, Sung Su; Kang, Jin Mo; Choi, Sang Tae; Park, Jae Hyung [Gachon University Gil Hospital, Incheon (Korea, Republic of)

    2015-03-15

    The aim of this study was to evaluate the safety and efficacy of SEAL aortic stent-graft for abdominal aortoiliac aneurysms. Between October 2007 and January 2014, 33 patients with abdominal aortoiliac aneurysms were treated with SEAL aortic stent-graft. We evaluated the technical success rate, clinical and CT follow-up periods, major complications, need for additional interventional treatment, aneurysm-related mortality and clinical success rate. SEAL bifurcated aortic stent-graft was successfully placed in 32 patients (97%). Clinical and CT follow-up periods were 24 and 14 months, respectively. Endoleak developed in 13 patients (41%): spontaneous regression or decrease in 6, need for additional treatment in 4 and follow-up loss in 3. Significant stenosis of stent-graft occurred in 4 patients (12%) and was treated with stenting in 3. Migration of stent-graft was noted in 3 patients (9%) and treated with additional stent-grafting. Aneurysm-related mortality was 9% (3 of 33). The placement of SEAL stent-graft was effective in 26 patients (79%). The placement of SEAL aortic stent-graft was safe and effective in patients with aneurysms of abdominal aorta and iliac arteries. However, complicating endoleaks, stenosis and migration of the stent-graft developed during the follow-up. Therefore, regular CT follow-up seems to be mandatory.

  16. An overview of thin film nitinol endovascular devices.

    Science.gov (United States)

    Shayan, Mahdis; Chun, Youngjae

    2015-07-01

    Thin film nitinol has unique mechanical properties (e.g., superelasticity), excellent biocompatibility, and ultra-smooth surface, as well as shape memory behavior. All these features along with its low-profile physical dimension (i.e., a few micrometers thick) make this material an ideal candidate in developing low-profile medical devices (e.g., endovascular devices). Thin film nitinol-based devices can be collapsed and inserted in remarkably smaller diameter catheters for a wide range of catheter-based procedures; therefore, it can be easily delivered through highly tortuous or narrow vascular system. A high-quality thin film nitinol can be fabricated by vacuum sputter deposition technique. Micromachining techniques were used to create micro patterns on the thin film nitinol to provide fenestrations for nutrition and oxygen transport and to increase the device's flexibility for the devices used as thin film nitinol covered stent. In addition, a new surface treatment method has been developed for improving the hemocompatibility of thin film nitinol when it is used as a graft material in endovascular devices. Both in vitro and in vivo test data demonstrated a superior hemocompatibility of the thin film nitinol when compared with commercially available endovascular graft materials such as ePTFE or Dacron polyester. Promising features like these have motivated the development of thin film nitinol as a novel biomaterial for creating endovascular devices such as stent grafts, neurovascular flow diverters, and heart valves. This review focuses on thin film nitinol fabrication processes, mechanical and biological properties of the material, as well as current and potential thin film nitinol medical applications.

  17. Tratamiento endovascular inmediato con stent graft en laceración de aorta torácica traumática

    Directory of Open Access Journals (Sweden)

    R. Gómes Marques

    2002-12-01

    Full Text Available Paciente de 32 años, que ingresa a la sala de guardia por sufrir politraumatismo secundario a accidente automovilístico. Se le realiza Rx de tórax que evidencia ensanchamiento de mediastino con sospecha clínica y por estudios con TAC y ecotransesofágico de rotura de aorta torácica, confirmada por angiografía de aorta descendente que muestra una imágen compatible con pseudoaneurisma. Debido a que la paciente persiste hipotensa, se decide tratamiento inmediato por vía endovascular, colocando un stent graft expandible con balón, con resultado exitoso y sin complicaciones. En el seguimiento con TAC con contraste al mes, a los 6 meses y al año, no se observaron alteraciones de la prótesis ni leaks peri protésico o re-estenosis.

  18. Cerebral Arterial Fenestrations

    Science.gov (United States)

    Cooke, Daniel L; Stout, Charles E; Kim, Warren T; Kansagra, Akash P; Yu, John Paul; Gu, Amy; Jewell, Nicholas P; Hetts, Steven W; Higashida, Randall T; Dowd, Christopher F; Halbach, Van V

    2014-01-01

    Summary Arterial fenestrations are an anatomic variant with indeterminate significance. Given the controversy surrounding fenestrations we sought their prevalence within our practice along with their association with other cerebrovascular anomalies. We retrospectively reviewed 10,927 patients undergoing digital subtraction angiography between 1992 and 2011. Dictated reports were searched for the terms “fenestration” or “fenestrated” with images reviewed for relevance, yielding 228 unique cases. A Medline database search from February 1964 to January 2013 generated 304 citations, 127 cases of which were selected for analysis. Cerebral arterial fenestrations were identified in 228 patients (2.1%). At least one aneurysm was noted in 60.5% of patients, with an aneurysm arising from the fenestration in 19.6% of patients. Aneurysmal subarachnoid hemorrhage or non-aneurysmal subarachnoid hemorrhage were present in 60.1% and 15.8%, respectively. For the subset of patients with an aneurysm arising directly from a fenestration relative to those patients with an aneurysm not immediately associated with a fenestration, the prevalence of aneurysmal subarachnoid hemorrhage was 66.7% vs. 58.6% (p = 0.58). Fenestrations were more often within the posterior circulation (73.2%) than the anterior circulation (24.6%), though there was no difference in the prevalence of aneurysms within these groups (61.1% vs. 60.7%, p = 1.0). Cerebral arterial fenestrations are an anatomic variant more often manifesting at the anterior communicating arterial complex and basilar artery and with no definite pathological relationship with aneurysms. PMID:24976087

  19. Kissing-Y stenting for endovascular treatment of complex wide necked bifurcation aneurysms using Acandis Acclino stents: results and literature review.

    Science.gov (United States)

    Brassel, Friedhelm; Melber, Katharina; Schlunz-Hendann, Martin; Meila, Dan

    2016-04-01

    Y-configured stent assisted coiling is a promising therapeutic option to ensure safe coil embolization and preserve the affected arteries in complex wide necked aneurysms. We present our experience with self-expanding Acandis Acclino stents for the treatment of complex aneurysms using the kissing-Y technique. We retrospectively reviewed seven patients with seven complex aneurysms (three anterior communicating artery (AcomA), two middle cerebral artery, one basilar artery/superior cerebellar artery, and one vertebral artery/posterior inferior cerebellar artery) who were treated with the kissing-Y technique by stent assisted coiling from June 2013 to July 2014, with follow-up until January 2015. DSA follow-up was up to 17 months, with a mean follow-up period of 10 months. Six patients were treated electively and one in the acute phase of a subarachnoid hemorrhage. In all cases, closed cell Acandis Acclino stents were used. We evaluated procedural complications, clinical outcomes, and mid term angiographic follow-up. Additionally, a literature review is provided. In all patients, stents were successfully placed and implanted. One patient developed a periprocedural thromboembolic complication not directly related to the stents. No other periprocedural or postprocedural complications were encountered. Follow-up examinations showed stable and total occlusion of all coiled aneurysms. The results of our study show that the kissing-Y technique using closed cell Acandis Acclino stents followed by coil embolization is a feasible treatment option for selected complex bifurcation aneurysms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Development of radiolabelled compound using reactor producted RI - Evaluation of Ho-166 endovascular therapy to prevent restenosis after PTCA or stenting for occlusive coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Hee; Choi, Byung Il; Kim, Han Soo [Ajou University, Suwon (Korea)

    2000-04-01

    Occlusive coronary artery disease is managed successfully by percutaneous transfemoral coronary angioplasty (PTCA) or stenting with 95% success rate. However, restenosis after PTCA is not uncommon and the reported incidence of reocclusion is about 30 {approx} 40%. Therefore, the objective of the research was to develop endovascular brachytherapy using liquid form of Ho-166 in order to inhibit neointimal hyperplasia responsible for restenosis following PTCA or stenting. Our research was carried out in 3 stages: First stage - The effectiveness of radiation was confirmed by using animal model. Following over-sized balloon injury to rat carotid artery and porcine coronary artery, various external radiation doses were delivered. Second stage - For radiation dose distribution within the coronary artery and its surrounding tissues, Gafchromic film was used. In vitro dose distribution of Ho-166 utilizing water phantom and Gafchromic film was measured. Third stage - None uniform dose distribution from Ho-166 within the balloon caused by small air bubbles was eliminated by negative suction method. More accurate dose distribution was also possible using newly developed micrometer by our physicist. Limited number of human trial was performed without adverse effect. 40 refs. (Author)

  1. Endovascular Treatment of Chronic Mesenteric Ischemia by Crossing of Two Stents in a Patient with Celiacomesenteric Trunk

    Energy Technology Data Exchange (ETDEWEB)

    Khil, Eun Kyung; Lee, Jae Myeong [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon Hospital, Bucheon (Korea, Republic of)

    2013-06-15

    A 73-year-old woman was presented with a 3-month history of postprandial abdominal pain and weight loss. The patient had an anatomic variant of celiacomesenteric trunk (CMT), with complete occlusion of the superior mesenteric artery (SMA) and significant stenosis of the CMT ostium, resulting in chronic mesenteric ischemia. After several unsuccessful attempts at revascularization of the SMA, celiac artery stenting was performed, followed by SMA stent placement through the previously placed stent mesh into the occlusion site. The patient's symptoms completely resolved after treatment.

  2. Endovascular stent graft repair of thoracic aortic mural thrombus in a patient with polycythemia vera: a word of caution.

    Science.gov (United States)

    Fukuhara, Shinichi; Tyagi, Samuel; Clarke-Pearson, Emily; Bernik, Thomas

    2015-02-01

    Thoracic aortic mural thrombus (TAMT) is a rare pathology and potential source of cerebral, visceral, and peripheral emboli. We present a 62-year-old male in a hypercoagulable state due to primary polycythemia vera (PV) developed TAMT and catastrophic thromboembolisms despite aggressive medical and surgical management. The outcomes and adverse events of endovascular exclusion of TAMT in the presence of PV are unknown. We would recommend proceeding with extreme caution when performing endovascular exclusion of TAMT, as PV may be a prohibitive risk.

  3. [Endovascular treatment of critical basilar stenosis with a Solitaire® stent device: a first experience in our centre].

    Science.gov (United States)

    Mulero, Patricia; Cortijo-García, Elisa; Ruiz-Piñero, Marina; Pérez-Fernández, Santiago; Arenillas-Lara, Juan F; Martínez-Galdámez, Mario

    2014-08-01

    Introduccion. Aunque la arterioesclerosis intracraneal es una causa importante de ictus, la actitud terapeutica no esta claramente establecida. En este sentido, el estudio SAMMPRIS comparo el tratamiento medico intensivo con la angioplastia y colocacion de stent, con resultados favorables al tratamiento farmacologico. Estos resultados podrian, en parte, deberse al dispositivo utilizado (stent Wingspan ®). Caso clinico. Varon de 71 años con una estenosis grave de la arteria basilar, en quien se repetian episodios de focalidad neurologica transitoria a pesar del tratamiento con doble antiagregacion y estatinas. En estas circunstancias se decidio realizar una arteriografia terapeutica con angioplastia y colocacion de un stent Solitaire ® para optimizar resultados y se logro una estenosis residual del 40%. La evolucion fue favorable y los controles posteriores muestran una minima progresion. Conclusion. Segun nuestro conocimiento, este es el primer caso publicado de tratamiento de una estenosis critica de la arteria basilar mediante la colocacion de un stent Solitaire ®.

  4. Endovascular repair of a juxtarenal saccular aneurysm using the Multilayer Flow Modulator: report of the first case performed in a Public Hospital in Brazil

    Directory of Open Access Journals (Sweden)

    Rodrigo Gibin Jaldin

    2014-09-01

    Full Text Available Endovascular treatment of abdominal aortic aneurysms (AAA, involving the exits of the renal and visceral arteries still constitutes a considerable challenge. Many different techniques have been developed over the years in attempts to surmount the difficulties presented by these cases. Techniques that have gained prominence include fenestrated or branched stents, methods involving parallel prostheses, such as the chimney, periscope and sandwich techniques, and, more recently, flow modulation with Multilayer stents. We describe a case of a complex juxtarenal saccular AAA with a high surgical risk, both according to cardiological assessment and because the patient had a difficult airway caused by a total laryngectomy for early stage laryngeal neoplasm. In view of the technical simplicity of using Multilayer stents, the presence of chronic obstructive aortoiliac disease, ostial stenosis of the renal artery and a small diameter suprarenal aorta, options involving fenestrated/branched stents and techniques involving parallel prostheses were ruled out, because of the need for multiple accesses. In view of the dilemma it presented, we describe this case as a therapeutic challenge and present the treatment option employed, which has been successful over the short term.

  5. Three new techniques for creation of a steerable sheath, a 4F snare, and bidirectional sheath inversion using existing endovascular materials.

    Science.gov (United States)

    Mallios, Alexandros; Yankovic, Willy; Boura, Benoit; Combes, Myriam

    2012-09-01

    We present three novel techniques for creation of (1) a steerable sheath, (2) a 4F snare device, and (3) dual anterograde and retrograde double-wire percutaneous transluminal angioplasty access technique using a single femoral puncture. These techniques were conceived and bench-tested in our institution, allowing the utilization of inexpensive equipment for complicated endovascular procedures. They offer (1) controlled navigation, no-touch vessel cannulation and cannulation of angulated vessels, contralateral limb of stent grafts, fenestrations, and branches; (2) a low-profile (4F external diameter) modifiable snare with the ability to expand to the size of an entire aneurysm and the ability to undo the snare in case of blockage with other endovascular material; and (3) in situ sheath inversion for concomitant anterograde and retrograde percutaneous angioplasty with a single femoral puncture.

  6. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    , covering, endovascular, revascularisation and thoracic aorta. We have gathered the most complete scientific evidence available used to support the various concepts to deal with this issue. After a review of the current available literature, 23 relevant articles were found, where we have identified...... and analysed three basic treatment concepts for LSA revascularisation in TEVAR patients (prophylactic, conditional prophylactic and no prophylactic LSA revascularisation). The available evidence supports prophylactic revascularisation of the LSA before ESG LSA coverage when preoperative imaging reveals...

  7. Creating a Fontan fenestration in a child with dextrocardia and interrupted inferior vena cava.

    Science.gov (United States)

    Charlagorla, Pradeepkumar; Breinholt, John P

    2016-01-01

    Plastic bronchitis is a rare life-threatening complication of the Fontan operation. Transcatheter Fontan fenestration can ameliorate symptoms by decompressing elevated venous pressures. Transcatheter creation of a fenestration can be technically challenging in cases with complex venous anatomy. We report a case of a 5-year-old boy with heterotaxy, dextrocardia with unbalanced atrioventricular canal (AVC), atrial and visceral situs inversus, left-sided superior vena cava (SVC), and left-sided interrupted inferior vena cava (IVC) with azygos continuation. With few modifications to the equipment, a successful Fontan fenestration with stent implantation was performed via transjugular approach. At 2-year follow-up, his symptoms of plastic bronchitis improved significantly.

  8. Tratamento endovascular com stent coberto de aneurisma carotídeo associado a arterite rádica Endovascular treatment with a covert-stent of radiation-associated carotid aneurysm

    Directory of Open Access Journals (Sweden)

    Emanuel Dias

    2011-03-01

    Full Text Available Introdução: O uso de radioterapia no tratamento de neoplasias pode causar inflamação e fibrose nas artérias adjacentes e levar a estenose com significado clínico ou, raramente, à formação de aneurismas. A arterite carotídea associada à radioterapia tem surgido como critério anatómico de alto risco para a endarterectomia carotídea (CEA, sendo a arterioplastia e stenting carotídeo (CAS encarado como uma alternativa terapêutica atrativa, apesar da falta de dados acerca dos resultados a longo prazo nesta indicação. Caso clínico: Homem de 70 anos, com antecedentes de neoplasia da laringe em 1998, sujeito a laringectomia radical e a radioterapia adjuvante. Admitido electivamente para tratamento de estenose da artéria carótida primitiva (ACC direita superior a 70%, medida em velocimetria de Eco-doppler, e de pequeno aneurisma do bulbo carotídeo ipsilateral. Apresentava história de acidente isquémico transitório 3 meses antes. O doente foi sujeito a colocação de stent coberto Viabahn® por via percutânea femoral direita na presença de dispositivo de protecção cerebral FilterWire EZ™, cobrindo as artérias carótidas comum e interna direitas no intuito de tratar a estenose da ACC e a dilatação aneurismática do bulbo carotídeo. O seguimento aos 6 meses não mostrou intercorrências. Conclusão: A utilização de um stent coberto para tratamento deste caso de arterite carotídea associada à radiação mostrou-se uma opção simples, eficaz e sem o risco das complicações associadas à cirurgia convencional.Introduction: Clinically significant arterial stenosis and aneurysm may result from inflamation and fibrosis induced by radiotherapy directed to an adjacent tumour. Carotid artery arterioplasty and stenting (CAS have revealed as valid alternatives to carotid endarteriectomy (CEA in patients with high risk such as patients with carotid arteritis secondary to radiotherapy. However, long-term follow-up are sparse

  9. Features of endovascular stent materials and their therapeutic effects on ischemic stroke%血管内支架材料特点与缺血性脑卒中的治疗效果★

    Institute of Scientific and Technical Information of China (English)

    郭奕彤; 谭志刚

    2013-01-01

    BACKGROUND: Novel endovascular stent materials have become the research hot spot in the treatment of ischemic stroke. OBJECTIVE: To analyze the features of endovascular stent materials and the treatment effect on ischemic stroke. METHODS: Related databases were searched by the first author with computer at December 2012 for the related articles published from 2003 to 2012. The Chinese key words were “ischemic stroke, endovascular stent, stent material, interventional treatment”. A total of 120 articles were screened out, and 24 articles were included for the final review according to the inclusion criteria. RESULTS AND CONCLUSION: Long-term storage of bare-metal stents in the blood may lead to corrosion, metal ions dissolution and coagulation; the surface modification of the metal material could be used to solve the problem of metal material storage in order to improve the blood compatibility of the metal materials. Therapeutic drugs were coated on the surface of stent which can help the drugs release with high concentration continuously, and this method can inhibit restenosis after stent implantation. Film-covered endovascular stent was covered with degradable or non-degradable polymer films on the surface of metal stent in order to inhibit the vascular endothelial proliferation and restenosis after stent implantation, and the film-covered endovascular stent could promote the biocompatibility of vascular smooth muscle cells. Endovascular stent is a safe and effective treatment method to reduce the risk of ischemic stroke, and it can also improve the cognitive dysfunction of the patients with ischemic encephalopathy. Gene and cel cultivation scaffold material has certain advantages in the prevention and treatment of restenosis after vascular intervention, which is the new direction for the research of endovascular stent materials.%  背景:新型血管内支架材料是目前脑血管疾病介入治疗的研究热点。目的:分析血管内支架材

  10. Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft.

    LENUS (Irish Health Repository)

    Molony, David S

    2009-01-01

    BACKGROUND: Abdominal aortic aneurysms (AAA) are local dilatations of the infrarenal aorta. If left untreated they may rupture and lead to death. One form of treatment is the minimally invasive insertion of a stent-graft into the aneurysm. Despite this effective treatment aneurysms may occasionally continue to expand and this may eventually result in post-operative rupture of the aneurysm. Fluid-structure interaction (FSI) is a particularly useful tool for investigating aneurysm biomechanics as both the wall stresses and fluid forces can be examined. METHODS: Pre-op, Post-op and Follow-up models were reconstructed from CT scans of a single patient and FSI simulations were performed on each model. The FSI approach involved coupling Abaqus and Fluent via a third-party software - MpCCI. Aneurysm wall stress and compliance were investigated as well as the drag force acting on the stent-graft. RESULTS: Aneurysm wall stress was reduced from 0.38 MPa before surgery to a value of 0.03 MPa after insertion of the stent-graft. Higher stresses were seen in the aneurysm neck and iliac legs post-operatively. The compliance of the aneurysm was also reduced post-operatively. The peak Post-op axial drag force was found to be 4.85 N. This increased to 6.37 N in the Follow-up model. CONCLUSION: In a patient-specific case peak aneurysm wall stress was reduced by 92%. Such a reduction in aneurysm wall stress may lead to shrinkage of the aneurysm over time. Hence, post-operative stress patterns may help in determining the likelihood of aneurysm shrinkage post EVAR. Post-operative remodelling of the aneurysm may lead to increased drag forces.

  11. Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft

    Directory of Open Access Journals (Sweden)

    McGloughlin Tim M

    2009-10-01

    Full Text Available Abstract Background Abdominal aortic aneurysms (AAA are local dilatations of the infrarenal aorta. If left untreated they may rupture and lead to death. One form of treatment is the minimally invasive insertion of a stent-graft into the aneurysm. Despite this effective treatment aneurysms may occasionally continue to expand and this may eventually result in post-operative rupture of the aneurysm. Fluid-structure interaction (FSI is a particularly useful tool for investigating aneurysm biomechanics as both the wall stresses and fluid forces can be examined. Methods Pre-op, Post-op and Follow-up models were reconstructed from CT scans of a single patient and FSI simulations were performed on each model. The FSI approach involved coupling Abaqus and Fluent via a third-party software - MpCCI. Aneurysm wall stress and compliance were investigated as well as the drag force acting on the stent-graft. Results Aneurysm wall stress was reduced from 0.38 MPa before surgery to a value of 0.03 MPa after insertion of the stent-graft. Higher stresses were seen in the aneurysm neck and iliac legs post-operatively. The compliance of the aneurysm was also reduced post-operatively. The peak Post-op axial drag force was found to be 4.85 N. This increased to 6.37 N in the Follow-up model. Conclusion In a patient-specific case peak aneurysm wall stress was reduced by 92%. Such a reduction in aneurysm wall stress may lead to shrinkage of the aneurysm over time. Hence, post-operative stress patterns may help in determining the likelihood of aneurysm shrinkage post EVAR. Post-operative remodelling of the aneurysm may lead to increased drag forces.

  12. The PROTAGORAS study to evaluate the performance of the Endurant stent graft for patients with pararenal pathologic processes treated by the chimney/snorkel endovascular technique.

    Science.gov (United States)

    Donas, Konstantinos P; Torsello, Giovanni B; Piccoli, Gianluca; Pitoulias, Georgios A; Torsello, Giovanni Federico; Bisdas, Theodosios; Austermann, Martin; Gasparini, Daniele

    2016-01-01

    The chimney/snorkel endovascular aortic repair (ch-EVAR) is gaining ever-greater acceptance in the treatment of pararenal pathologic processes. However, the published experience includes mainly short-term clinical results with combinations of several abdominal devices and types of chimney grafts. The aim of this study was the midterm evaluation of the Endurant stent graft (Medtronic, Santa Rosa, Calif) as a standard abdominal device for ch-EVAR. Between January 2009 and January 2013, prospectively collected data of high-risk patients with pararenal pathologic processes who underwent ch-EVAR with placement of the Endurant abdominal device were analyzed. The chimney graft intended for use was a balloon-expandable covered stent. Main outcome measures were aneurysm sac regression and chimney graft patency. A total of 187 snorkel/chimney grafts were successfully placed in 128 patients (mean age, 76.6 years). The technical success was 100%. The mean preoperative proximal neck length and aneurysm size were 4.7 mm and 64.8 mm (range, 48-135 mm), respectively. The postoperative new neck length after use of chimney grafts was 18.7 ± 6.3 mm. The mean aneurysm sac decreased significantly (60.8 mm; 95% confidence interval, 2.036-7.084; P = .001) after a mean radiologic follow up of 24.6 ± 17.4 months. Thirty-day mortality and midterm mortality were 0.8% and 17.2%, respectively. Two patients (1.6%) with single chimneys presented with late new onset of type Ia endoleak and underwent additional tube and multiple chimney placement. Primary chimney graft patency was 95.7%. Freedom from chimney graft-related reinterventions was 93.1%. Standard use of the Endurant abdominal device for ch-EVAR in >120 patients is associated with high technical success, significant aneurysm sac regression, and low incidence of secondary procedures after 2-year radiologic follow-up. These results will give significant impetus to device selection, facilitating the standardization of technique. Copyright

  13. Hypersensitivity reactions associated with endovascular devices.

    Science.gov (United States)

    Honari, Golara; Ellis, Stephen G; Wilkoff, Bruce L; Aronica, Mark A; Svensson, Lars G; Taylor, James S

    2008-07-01

    Allergic reactions to endoprostheses are uncommon and reported in association with orthopaedic, dental, endovascular and other implanted devices. Hypersensitivity reactions to the biomaterials used in endovascular prostheses are among the infrequent reactions that may lead to local or systemic complications following cardiovascular therapeutic interventions. This article reviews potential immunotoxic effects of commonly used biomaterials. Reports of putative hypersensitivity reactions to endovascular devices, including coronary stents, perforated foramen occluders, pacemakers and implantable cardioverter defibrillators are also reviewed.

  14. Early Experiences of Sandwich Technique to Preserve Pelvic Circulation during Endovascular Aneurysm Repair.

    Science.gov (United States)

    Kim, Daehwan; Chung, Jung Kee; Park, Hyung Sub; Jung, In Mok; Lee, Taeseung

    2017-06-01

    To report experiences of the sandwich technique (ST) for preservation of pelvic flow during endovascular repair of complex aortic or aortoiliac aneurysms. Eight patients underwent elective endovascular aneurysm repair (EVAR) using the ST between March 2013 and February 2017. The anatomic indications for the ST were complex aortoiliac aneurysms (5 cases), abdominal aortic aneurysms (AAA) with non-diseased short common iliac arteries (2 cases) and AAA with unilateral occluded iliac artery (1 case). The ST was performed through both femoral and brachial approach. Patient clinical and radiologic data were collected and analyzed. Eight patients (7 male; mean age, 73.4 years) were followed over a mean period of 277 days (range, 9-1,106 days). The technical success rate was 100%. The primary patency rate of the iliac stent-grafts was 88% (14/16 cases). One internal iliac and 1 external iliac stent-graft occlusion was observed during the early postoperative period. There was 1 gutter endoleak which disappeared spontaneously within 4 days, and there were 2 type II endoleaks: one treated by coil embolization after 13 months, and the other observed without treatment. There were no cases of sac growth or aneurysm-related deaths, and no cases of buttock claudication or impotence. The ST is a safe and feasible technique to preserve pelvic circulation during endovascular treatment of complex aortoiliac aneurysms. The need to expand the indications for complex EVARs with adjunctive procedures, such as the ST is highlighted in situations where branched/fenestrated device availability is limited.

  15. Retrograde ascending aortic dissection during or after thoracic aortic stent graft placement: insight from the European registry on endovascular aortic repair complications

    DEFF Research Database (Denmark)

    Eggebrecht, Holger; Thompson, Matt; Rousseau, Hervé

    2009-01-01

    BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic...

  16. Thirty-day outcome and quality of life after endovascular abdominal aortic aneurysm repair in octogenarians based on the Endurant Stent Graft Natural Selection Global Postmarket Registry (ENGAGE)

    NARCIS (Netherlands)

    Pol, Robert A.; Zeebregts, Clark J.; van Sterkenburg, Steven M. M.; Reijnen, Michel M. P. J.

    Objectives: To determine 30-day outcome and quality of life after elective endovascular abdominal aortic aneurysm repair in octogenarians. Methods: From March 2009 to May 2011, 1200 patients with abdominal aortic aneurysms were treated with endovascular aneurysm repair (EVAR) using the Endurant

  17. A special type of endovascular stent repair with complicated thoracic aneurysm and chronic type B dissection aligned in tandem: double perfusion in true and false distal aorta lumen

    Institute of Scientific and Technical Information of China (English)

    GAN Hui-li; ZHANG Jian-qun

    2008-01-01

    @@ Aortic dissection and aortic aneurysm are two of the most common catastrophic events involving the aorta. Thoracic endovascular aortic repair is now considered as a promising alternative to open surgical graft replacement, The aim of endovascular repair of a thoracic aneurysm is to exclude, and thus depressurize, the aneurismal wall and the aim of the endovascular repair of type B aortic dissection is to obliterate all of the false lumen through thrombosis after sealing the primary entry tears, thus to ensure the true lumen perfusion.

  18. Endovascular therapy of high-degree stenoses of the neck vessels-stent-supported percutaneous angioplasty of the carotid artery without cerebral protection; Endovaskulaere Behandlung hochgradiger Halsgefaessstenosen - Stentgestuetzte perkutane Angioplastie der Arteria Carotis ohne Protektion

    Energy Technology Data Exchange (ETDEWEB)

    Koch, C.; Kucinski, T.; Eckert, B.; Wittkugel, O.; Zeumer, H. [Abt. fuer Neuroradiologie, Universitaetsklinikum Hamburg Eppendorf (Germany); Roether, J. [Klinik fuer Neurologie, Universitaetsklinikum Hamburg Eppendorf (Germany)

    2002-12-01

    Purpose: Technical essentials and therapeutic results of carotid stenting without cerebral protection are presented. Materials and methods: In 161 patients, 167 high grade carotid stenoses were stented, followed by percutaneous transluminal angioplasty, with subsequent evaluation of the clinical and angiographic results. Diffusion-weighted MRI was carried out in 108 patients to detect cerebral sequelae. Results: Endovascular therapy was successful (residual stenosis <25%) in 166 stenoses (99.4%). Twelve patients (7.5%) had cerebrovascular complications within the 30-day perioperative period, seven of which occurred during the procedure. After treatment, diffusion-weighted MRI disclosed at least one new cerebral lesion in 40 patients (37%), which were symptomatic in six patients. Conclusion: Even without cerebral protection, high grade carotid stenosis can be safely treated with stent-protected percutaneous angioplasty. Microemboli detected by postoperative MRI are infrequently symptomatic. (orig.) [German] Ziel: Es werden die Durchfuehrung der direkten Stentangioplastie der A.ccarotis ohne zerebrale Protektion und die Ergebnisse dieses Behandlungsverfahrens beschrieben. Methoden: Bei 161 Patienten wurden 167 hochgradige Karotisstenosen durch Platzieren eines Stents mit anschliessender perkutaner transluminaler Angioplastie behandelt. Die Behandlungsergebnisse wurden klinisch und angiographisch bewertet. 108 Patienten wurden mit diffusionsgewichteter MRT zum Nachweis klinisch stummer Infarkte untersucht. Ergebnisse: 166 Stenosen (99,4%) wurden erfolgreich behandelt (Reststenose <25%). Im perioperativen Zeitraum von 30 Tagen trat bei insgesamt 12 Patienten eine zerebrovaskulaere Komplikation auf (7,5%), 7 Patienten erlitten die Komplikation waehrend des Eingriffs. Nach der Behandlung hatten 40 Patienten (37%) mindestens eine neue zerebrale Diffusionsstoerung, 6 davon mit klinischen Symptomen. Schlussfolgerungen: Mit der stentgestuetzten perkutanen Angioplastie

  19. Endovascular treatment of blister aneurysms.

    Science.gov (United States)

    Peitz, Geoffrey W; Sy, Christopher A; Grandhi, Ramesh

    2017-06-01

    Blister aneurysms are rare cerebrovascular lesions for which the treatment methods are reviewed here, with a focus on endovascular options. The reported pathogenesis of blister aneurysms varies, and hemodynamic stress, arterial dissection, and arteriosclerotic ulceration have all been described. There is consensus on the excessive fragility of blister aneurysms and their parent vessels, which makes clipping technically difficult. Open surgical treatment is associated with high rates of complications, morbidity, and mortality; endovascular treatment is a promising alternative. Among endovascular treatment options, deconstructive treatment has been associated with higher morbidity compared with reconstructive methods such as direct embolization, stent- or balloon-assisted direct embolization, stent monotherapy, and flow diversion. Flow diversion has been associated with higher technical success rates and similar clinical outcomes compared with non-flow diverting treatment methods. However, delayed aneurysm occlusion and the need for antiplatelet therapy are potential drawbacks to flow diversion that must be considered when choosing among treatment methods for blister aneurysms.

  20. [Endovascular surgery in the war].

    Science.gov (United States)

    Reva, V A; Samokhvalov, I M

    2015-01-01

    Rapid growth of medical technologies has led to implementation of endovascular methods of diagnosis and treatment into rapidly developing battlefield surgery. This work based on analysing all available current publications generalizes the data on using endovascular surgery in combat vascular injury. During the Korean war (1950-1953) American surgeons for the first time performed endovascular balloon occlusion of the aorta - the first intravascular intervention carried out in a zone of combat operations. Half a century thereafter, with the beginning of the war in Afghanistan (2001) and in Iraq (2003) surgeons of central hospitals of the USA Armed Forces began performing delayed endovascular operations to the wounded. The development of technologies, advent of mobile angiographs made it possible to later on implement high-tech endovascular interventions in a zone of combat operations. At first, more often they performed implantation of cava filters, somewhat afterward - angioembolization of damaged accessory vessels, stenting and endovascular repair of major arteries. The first in the theatre of war endovascular prosthetic repair of the thoracic aorta for severe closed injury was performed in 2008. Russian experience of using endovascular surgery in combat injuries is limited to diagnostic angiography and regional intraarterial perfusion. Despite the advent of stationary angiographs in large hospitals of the RF Ministry of Defence in the early 1990s, endovascular operations for combat vascular injury are casuistic. Foreign experience in active implementation of endovascular technologies to treatment of war-time injuries has substantiated feasibility of using intravascular interventions in tertiary care military hospitals. Carrying out basic training courses on endovascular surgery should become an organic part of preparing multimodality general battlefield surgeons rendering care on the theatre of combat operations.

  1. The use of covered stents for the endovascular treatment of extracranial internal carotid artery stenosis: a prospective study with a 5-year follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Szolics, Alex; Szikra, Peter; Palko, Andras; Voeroes, Erika [University of Szeged, Department of Radiology, Szeged (Hungary); Sztriha, Laszlo K. [University of Szeged, Department of Neurology, Szeged (Hungary); Szolics, Miklos [Tawam Hospital in affiliation with Johns Hopkins Medicine, Division of Neurology, Al Ain, P.O. Box 15258, Abu Dhabi Emirate (United Arab Emirates)

    2010-07-15

    To evaluate the safety and feasibility of the use of covered stents for the treatment of extracranial carotid artery stenosis caused by highly embologenic plaques, and to study the long-term outcome of patients receiving such covered stents. Between 2002 and 2007, 46 patients (63% symptomatic, 78.3% male, 67 {+-} 8.6 years old) with internal carotid artery stenosis caused by embologenic plaques or restenosis were treated with self-expanding covered stents (Symbiot, Boston Scientific). Pre-dilatation or protecting devices were not used. Post-dilatation was applied in every patient. Each patient was followed long-term. The outcome measures were the occurrence of neurological events, and the development of in-stent restenosis, as detected by clinical examination and duplex ultrasound. The technical success rate of stenting was 100%. There were no neurological complications in the peri-procedural period. The mean follow-up period was 34.3 {+-} 27.7 months (the rate of patients lost to follow-up was 15.2%) during which no stroke or stroke-related deaths occurred. Restenosis was detected in 3 patients (6.5%). Covered stents provide efficient peri- and post-procedural protection against neurological complications due to embolisation from high-risk plaques during carotid artery stenting. Restenosis of covered stents appears to be infrequent during long-term follow-up. (orig.)

  2. Minimally Invasive Treatment of Biventricular Hydrocephalus Caused by a Giant Basilar Apex Aneurysm via a Staged Combination of Endoscopy and Endovascular Embolization: A Case Report.

    Science.gov (United States)

    Setty, Pradeep; Volkov, Andrey; Richards, Boyd; Barrett, Ryan

    2015-01-01

    Biventricular hydrocephalus caused by a Giant Basilar Apex Aneurysm (GBAA) is a rare finding that presents unique and challenging treatment decisions. We report a case of GBAA causing a life-threatening biventricular hydrocephalus in which both the aneurysm and hydrocephalus were given definitive treatment through a staged, minimally invasive approach. An obtunded 82-year-old male was found to have biventricular hydrocephalus caused by an unruptured GBAA obstructing the foramina of Monro. The patient was treated via staged, minimally invasive technique that first involved endoscopic fenestration of the septum pellucidum to create communication between the lateral ventricles. A programmable ventriculo-peritoneal shunt was then placed with a high-pressure setting. The patient was then loaded with dual anti-platelet therapy prior to undergoing endovascular coiling of the GBAA with adjacent stenting of the Posterior Cerebral Artery. He remained on dual anti-platelet therapy and the shunt setting was lowered at the bedside to treat the hydrocephalus. At 6-month follow up, the patient had returned to his cognitive baseline, speaking fluently and appropriately. Biventricular hydrocephalus caused by a GBAA can successfully be treated in a minimally invasive fashion utilizing a combination of endoscopy and endovascular therapy, even when a stent-assisted coiling is needed.

  3. Fenestration of the anterior cerebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Ito, J.; Washiyama, K.; Hong, K.C.; Ibuchi, Y.

    1981-08-01

    Three cases of angiographically demonstrated fenestration of the anterior cerebral artery are reported. Fenestration occurred at the medial half of the horizontal segment of the anterior cerebral artery in all cases. Its embryology and clinical significance are briefly discussed, and the anatomical and radiological literature on fenestration of the anterior cerebral artery is reviewed.

  4. 胸主动脉夹层动脉瘤腔内隔绝术的麻醉管理%Anesthesia for endovascular stent-graft implantation of thoracic aortic dissection

    Institute of Scientific and Technical Information of China (English)

    夏氢; 陈伟; 李卫; 蒋岚杉; 崔驰

    2011-01-01

    Objective To present the anesthetic management of patients for endovascular stent-graft implantation of thoracic aortic dissection. Methods Twenty-nine patients with thoracic aortic dissection were underwent endovascular stent-graft implantation under combined intravenous-inhalation anesthesia and controlled hypotension. Anesthesia was induced with midazolam, propofol, fentanyl and atracuriura, and maintained with propofol, fentanyl, atracurium, isoflurane or sevoflurane. Continuous e-lectrocardiogram, invasive blood pressure, central venous pressure, percutaneous oxygen saturation, end-tidal carbon dioxide tensions and urine output were monitored. Arterial blood gas, plasma electrolyte and blood sugar were monitored if necessary. An intravenous infusion of nitroglycerin[0. 5~5 μg/(kg ? Min) ] was given to maintain systolic pressure at 90~100mmHg before release of the stent. Results The anaesthesia times were ( 120. 28 ± 15. 25) minutes. The anesthetic effects were satisfactory and the hemodynamics was steady. Before release of the stent, mean arterial blood pressure was reduced to (65.13 ± 14. 32) mmHg. All of them had no anesthesia complications. Conclusion Appropriate preoperative preparation, controlled hypotension and systemic organ protection are very important in the anesthetic management of patients for endovascular stent-graft implantation of thoracic aortic dissection.%目的 探讨胸主动脉夹层动脉瘤实施腔内隔绝术的麻醉方法及麻醉管理要点.方法 29例胸主动脉夹层动脉瘤患者均在静吸复合全身麻醉和控制性降压下实施手术,麻醉诱导采用咪唑安定、丙泊酚、芬太尼及阿曲库铵,麻醉维持采用丙泊酚、芬太尼、阿曲库铵、异氟烷或七氟烷.术中持续监测心电图、有创动脉血压、中心静脉压、脉搏血氧饱和度、呼气末二氧化碳分压及尿量,必要时监测动脉血气、电解质及血糖等.支架释放时微泵输注硝酸甘油0.5~5μg

  5. Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: mid-term and long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Sedat, Jacques; Chau, Yves; Mondot, Lydiane [CHU Nice, Unite de Neurointerventionnelle, Hopital St. Roch, Nice (France); Vargas, Julian; Szapiro, Jacek; Lonjon, Michel [CH Bastia, Service de Neurochirurgie, Bastia (France)

    2009-06-15

    Coiling associated with placement of self-expandable intracranial stents has amplified the treatment of intracranial wide-necked aneurysms, but the durability of this treatment and the existence of delayed recurrence are not yet well known. The purpose of this report is to present our experience with the Neuroform Stent associated with coiling and to evaluate complications, effectiveness, and long-term results of this technique. A retrospective study of 42 patients with wide-necked cerebral aneurysms treated with the Neuroform Stent was performed. Mean aneurysm size was 11.3 mm. Mean neck size was 5.33 mm. All patients were treated with coiling and stenting. Clinical and angiographic follow-up was available in 38 patients (90.5%). The overall follow-up time ranged from 6 months to 5 years (mean, 42 months), but most of the patients (92%) had a follow-up period superior to 1 year. Successful deployment of 41 stents (97%) was obtained. Permanent procedural morbidity was observed in only one patient (2.4%). Long-term complete aneurysmal occlusion was obtained in 27 patients (71%). Aneurysmal regrowth was observed in four patients (9.5%) on the first control angiogram. After the first control angiogram, no delayed recanalization or regrowth was observed. During the follow-up period, there were no hemorrhagic events, no delayed thrombosis, and no stent displacement. Our results demonstrate the effectiveness of the technique, a small rate of procedural complications, and long-term tolerance of the Neuroform Stent. Despite some evidence of early aneurysmal recurrence, long-term durability of stent-assisted aneurysm occlusion is stable after the first year. (orig.)

  6. Outcomes for supra-aortic branch vessel stenting in the treatment of thoracic aortic disease.

    Science.gov (United States)

    O'Callaghan, Adrian; Mastracci, Tara M; Greenberg, Roy K; Eagleton, Matthew J; Bena, James; Kuramochi, Yuki

    2014-10-01

    Endovascular options for the treatment of proximal thoracic and arch disease have evolved over the years. In this manuscript, we review the midterm results of fenestrated compared with chimney configurations for proximal aortic aneurysm disease. We performed an analysis of all patients with chimney grafts or custom fenestrated endografts used for treatment of proximal thoracic aneurysm disease (involving the supra-aortic trunk vessels) presenting to our institution between 2004 and 2013. Patients were identified by retrospective chart review and through the prospective database (National Institutes of Health study number NCT00583050). Details of devices placed, intraoperative details, and measurements from postoperative imaging were included in the analysis. The primary outcomes of interest were long-term freedom from branch stent complications and freedom from proximal endoleak, but we also included perioperative events, in-hospital mortality, and requirement for secondary interventions in our review. The log-rank test (Mantel-Cox) was used to compare survival data. Student t-test (two tailed) and Fisher exact test (two tailed) were used for continuous and categorical data, respectively. Of 767 patients who underwent thoracic endovascular repair from January 2004 to February 2013, 33 satisfied the inclusion criteria (4%): 18 of 33 noncustom and 15 of 33 custom graft designs. Overall, the rate of technical success was 97%. There were four branch stent-related problems in the follow-up period, one of 15 (7%) in the custom group and three of 18 (17%) in the noncustom group. There were three proximal sealing failures in the immediate postoperative and follow-up period, one of 15 (7%) in the custom group and two of 18 (11%) in the noncustom group. Overall, 10 patients underwent secondary procedures, four of 15 (27%) in the custom group and six of 18 (33%) in the noncustom group. Although they are technically feasible, both custom fenestrated endografts and chimney

  7. Creating a Fontan fenestration in a child with dextrocardia and interrupted inferior vena cava

    Directory of Open Access Journals (Sweden)

    Pradeepkumar Charlagorla

    2016-01-01

    Full Text Available Plastic bronchitis is a rare life-threatening complication of the Fontan operation. Transcatheter Fontan fenestration can ameliorate symptoms by decompressing elevated venous pressures. Transcatheter creation of a fenestration can be technically challenging in cases with complex venous anatomy. We report a case of a 5-year-old boy with heterotaxy, dextrocardia with unbalanced atrioventricular canal (AVC, atrial and visceral situs inversus, left-sided superior vena cava (SVC, and left-sided interrupted inferior vena cava (IVC with azygos continuation. With few modifications to the equipment, a successful Fontan fenestration with stent implantation was performed via transjugular approach. At 2-year follow-up, his symptoms of plastic bronchitis improved significantly.

  8. A novel method of creation of a fenestration in nitinol occluder devices used in closure of hypertensive patent arterial ducts

    Directory of Open Access Journals (Sweden)

    Anil Kumar Singhi

    2016-01-01

    Full Text Available Test occlusion with a balloon is done to predict operability of large hypertensive patent ductus arteriosus (PDA. If the fall in the pulmonary artery pressures is inadequate, a complete closure is not desired. To create a predictable premeasured fenestration in a nitinol occluder device used for closing hypertensive PDA. A large nitinol occluder device was punctured with an 18G needle to advance a 0.035½ stiff guide wire through the occluder before loading it into the delivery system. The occluder with the guidewire was then deployed across the PDA. A coronary guide catheter was later threaded through the guidewire into the fabric of the device, which was still held by the delivery cable. A coronary stent was deployed across the fenestration in the occluder to keep it patent. An 8-year-old boy with Down syndrome and hypertensive PDA was hemodynamically assessed. Even though there was a fall in the pulmonary vascular resistance index and pressures on test occlusion, the pulmonary artery pressures were labile with fluctuations. A customized fenestration was made in a 16 mm muscular ventricular septal defect occluder (MVSO with a 4.5 mm bare-metal coronary stent. The pulmonary artery pressures remained at half of the aortic pressures after the procedure. This fenestration model precisely and predictably fenestrated a large occluder device used to close a hypertensive large PDA. Long-term patency of these fenestrations has to be assessed on the follow-up, and may be improved through larger fenestrations, systemic anticoagulation and use of covered stents.

  9. Endovascular Iliocaval Stent Reconstruction for Inferior Vena Cava Filter-Associated Iliocaval Thrombosis: Approach, Technical Success, Safety, and Two-Year Outcomes in 120 Patients.

    Science.gov (United States)

    Chick, Jeffrey Forris Beecham; Jo, Alexandria; Meadows, J Matthew; Abramowitz, Steven D; Khaja, Minhaj S; Cooper, Kyle J; Williams, David M

    2017-07-01

    To report technical success, outcomes, and patency of iliocaval stent reconstruction for inferior vena cava (IVC) filter-bearing iliocaval thrombosis. A total of 120 patients with 123 IVC filters and symptomatic iliocaval thrombosis underwent stent reconstruction. Mean patient age was 55 years (range, 19-88 y). Filters included 70 (57%) retrievable and 53 (43%) permanent filters. Symptoms included lower extremity swelling or pain (n = 93), ulcers (n = 8), phlegmasia (n = 7), back pain (n = 5), shortness of breath (n = 4), worsening renal function (n = 2), and stenosis identified during translumbar catheter placement (n = 1). Clinical success was defined as decrease in clinical, etiology, anatomy, and pathophysiology (CEAP) score of at least 1; resolution of presenting symptoms; or normalization of renal function in patients with juxtarenal or suprarenal thrombosis on presentation. Technical aspects of reconstruction, technical success, complications, 6-month clinical response, and 6-, 12-, and 24-month primary, primary-assisted, and secondary stent patency rates were recorded. Stent reconstruction was technically successful in all 120 patients, 63 of whom (53%) underwent thrombolysis. Thirty filters (24%) were retrieved, and 93 (76%) were excluded with stent placement across the indwelling filter. Six minor and 2 major complications occurred. Clinical success was achieved in 115 patients (96%) at 6 months. Six-, 12-, and 24-month primary iliocaval stent patency rates were 96.4%, 94.8%, and 87.2%, respectively. Twenty-four month primary-assisted and secondary patency rates were 90.3% and 94.2%, respectively. Iliocaval stent reconstruction is an effective treatment for filter-associated thrombosis with 100% technical success and 96% clinical success at 6 months. Technical and clinical outcomes in patients who underwent filter retrieval versus filter exclusion were similar. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  10. Endovascular Repair of Infrarenal Abdominal Aortic Aneurysm with Unibody Bifurcated Stent-Grafts%分叉型一体式覆膜支架腔内治疗肾下型腹主动脉瘤的疗效

    Institute of Scientific and Technical Information of China (English)

    史伟浩; 余波; 王巍

    2012-01-01

    目的:探讨应用分叉型一体式覆膜支架腔内治疗腹主动脉瘤和髂动脉瘤的疗效.方法:回顾分析采用分叉型一体式覆膜支架治疗的20例肾下型腹主动脉瘤和髂动脉瘤患者的临床资料.结果:20例患者植入分叉型一体式覆膜支架的手术成功率达100%,无围手术期死亡患者,且所有患者均未出现各类缺血性并发症.8例患者术后存在少量内漏(6例Ⅰ型内漏,2例Ⅲ型内漏),1周后内漏消失;1例患者术后发生急性肝肾功能不全,经内科治疗1周后恢复;2例患者术后出现腹股沟切口淋巴瘘,经换药愈合.平均随访15个月,所有患者未出现新的内漏和支架移位.1例患者术后1年在左侧分支支架内形成血栓,左侧髂动脉局部无血流,经导管接触溶栓治疗1d后实现血管再通.结论:应用分叉型一体式覆膜支架腔内治疗腹主动脉瘤安全有效.%Objective: To summary the clinical experience in applying unibody bifurcated stent-grafts for endovascular treatment of abdominal aortic aneurysm and iliac aneurysm. Methods: From February 2009 to March 2012, unibody bifurcated stent-grafts had been applied in the treatment of 20 patients suffering from infrarenal abdominal aortic aneurysm and iliac aneurysm. Their clinical data were analyzed. Results: A total of 100% success rate of stent implantation has been achieved without periop-erative deaths and any ischemic complications; postoperative endoleak occured in 8 cases(6 cases of type I endoleak, 2 cases of type Ⅲ endoleak) , and endoleak disappeared in all of them within one week; acute liver and kidney dysfunction occurred in one case and it was relieved after medical treatment for one week; groin incision lymphatic fistula occurred in two cases and was healed by dressing change. Patients have been followed up for an average period of 15 months. No endoleak and stent migration occurred. Conclusions: Applying unibody bifurcated stent-graft for endovascular

  11. Pseudoaneurisme på arteria carotis interna behandlet med stent

    DEFF Research Database (Denmark)

    Benian, Cemil; Wagner, Aase; Cortsen, Marie

    2013-01-01

    Extracranial internal carotid artery aneurysms (EACIAs) are rare. Untreated they have a high stroke rate. Traditionally the treatment has been surgery or endovascular intervention with coils. Both are associated with relatively high complication rates. Another treatment option is endovascular int...... intervention with covered stent, which provides one-step closure of the aneurysm. As in the case story it can be complicated with in-stent occlusion. Therefore we recommend balloon occlusion test before treatment of EACIAs with covered stent....

  12. Successful Endovascular Repair of an Iatrogenic Perforation of the Superficial Femoral Artery Using Self-Expanding Nitinol Supera Stents in a Patient with Acute Thromboembolic Limb Ischemia

    Directory of Open Access Journals (Sweden)

    Tom Eisele

    2016-01-01

    Full Text Available The treatment of acute thromboembolic limb ischemia includes well-established surgical thrombectomy procedures and, in recent times, also percutaneous rotational thrombectomy using Straub Rotarex® system. This modality not only enables efficient treatment of such thrombotic occlusion but also in rare cases may imply the risk of perforation of the occluded artery. Herein, we report the case of a perforation of the superficial femoral artery (SFA in an elderly female patient with thromboembolic limb ischemia. The perforation was successfully treated by implantation of self-expanding nitinol Supera stents and without the need for implantation of a stent graft.

  13. Delayed endovascular treatment of descending aorta stent graft collapse in a patient treated for post- traumatic aortic rupture: a case report

    Directory of Open Access Journals (Sweden)

    Stegher Silvia

    2011-05-01

    Full Text Available Abstract Background We report a case of delayed endovascular correction of graft collapse occurred after emergent Thoracic Endovascular Aortic Repair (TEVAR for traumatic aortic isthmus rupture. Case presentation In 7th post-operative day after emergent TEVAR for traumatic aortic isthmus rupture (Gore TAG® 28-150, a partial collapse of the endoprosthesis at the descending tract occurred, with no signs of visceral ischemia. Considering patient's clinical conditions, the graft collapse wasn't treated at that time. When general conditions allowed reintervention, the patient refused any new treatment, so he was discharged. Four months later the patient complainted for severe gluteal and sural claudication, erectile disfunction and abdominal angina; endovascular correction was performed. At 18 months the graft was still patent. Discussion and Conclusion Graft collapse after TEVAR is a rare event, which should be detected and treated as soon as possible. Delayed correction of this complication can be lethal due to the risk of visceral ischemia and limbs loss.

  14. An Important but Forgotten Technique: Aortic Fenestration.

    Science.gov (United States)

    Yalcin, Mihriban; Tayfur, Kaptan Derya; Urkmez, Melih

    2016-10-01

    Aortic fenestration is a technique that treats organ ischemia in descending aortic dissection. Open surgical aortic fenestration is an effective yet uncommonly used and widely forgotten procedure. Here, we describe 2 patients suffering from chronic thoracoabdominal aortic dissection, and we aimed to identify under what circumstances surgical aortic fenestration should be applied, to assess its safety and efficacy. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. 一体化分叉型支架在肾下型腹主动脉瘤腔内治疗中的应用%Application of unibody bifurcated stent-graft in the endovascular treatment of infrarenal abdominal aortic aneurysm

    Institute of Scientific and Technical Information of China (English)

    朱豫; 张智勇; 卢绮萍

    2013-01-01

    Objective To investigate the unibody bifurcated stent-graft in the treatment of infra-renal abdominal aortic aneurysm. Methods The clinical data of 15 patients with infrarenal abdominal aortic aneurysm who underwent endovascular treatment with unibody bifurcated stent-graft from March 2010 to February 2013 were retrospectively analyzed. Results All cases were successfully treated by endovascular repair, and patients were followed up for 3 to 36 months to review the CTA. The aneurysms were completely isolated. The stents were in good position without displacement,distortion or endoleak. Conclusion After the preoperative assessment and measurement, the endovascular treatment with unibody bifurcated stent-graft for infrarenal abdominal aortic aneurysm has the advantages of good efficacy, high security, simple operation and few complications.%目的 探讨一体化支架在肾下型腹主动脉瘤治疗中的应用.方法回顾分析 2010 年3 月至 2013 年 2 月采用一体化支架腔内修复术治疗肾下型腹主动脉瘤15例,对其临床资料进行分析总结.结果 所有病例均腔内修复成功,术后随访3~36个月复查CTA,瘤体均被完全隔绝,支架位置良好,无移位、扭曲及内漏现象.结论 术前准确评估、测量后,一体化支架治疗肾下性腹主动脉瘤效果良好,安全性高,操作简单并发症少.

  16. Endovascular repair of blunt popliteal arterial injuries

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Shan; Zhang, Xiquan; Chen, Zhong; Zhu, Wei; Pan, Xiaolin [Dept. of nterventional Vascular, The 148th Hospital of Chinese People' s Liberation Army, Zibo (China); Dong, Peng; Sun, Yequan [Dept. of Medical Imaging, Weifang Medical University, Weifang (China); Qi, Deming [Dept. of Medical Imaging, Qilu Medical University, Zibo (China)

    2016-09-15

    To evaluate the feasibility and effectiveness of endovascular repair for blunt popliteal arterial injuries. A retrospective analysis of seven patients with clinical suspicion of popliteal arterial injuries that were confirmed by arteriography was performed from September 2009 to July 2014. Clinical data included demographics, mechanism of injury, type of injury, location of injury, concomitant injuries, time of endovascular procedures, time interval from trauma to blood flow restoration, instrument utilized, and follow-up. All patients were male (mean age of 35.9 ± 10.3 years). The type of lesion involved intimal injury (n = 1), partial transection (n = 2), complete transection (n = 2), arteriovenous fistula (n = 1), and pseudoaneurysm (n = 1). All patients underwent endovascular repair of blunt popliteal arterial injuries. Technical success rate was 100%. Intimal injury was treated with a bare-metal stent. Pseudoaneurysm and popliteal artery transections were treated with bare-metal stents. Arteriovenous fistula was treated with bare-metal stent and coils. No perioperative death and procedure-related complication occurred. The average follow-up was 20.9 ± 2.3 months (range 18–24 months). One patient underwent intra-arterial thrombolysis due to stent thrombosis at 18 months after the procedure. All limbs were salvaged. Stent migration, deformation, or fracture was not found during the follow-up. Endovascular repair seems to be a viable approach for patients with blunt popliteal arterial injuries, especially on an emergency basis. Endovascular repair may be effective in the short-term. Further studies are required to evaluate the long-term efficacy of endovascular repair.

  17. Early results with a monorail-stent-balloon device for endovascular treatment of renal artery stenosis; Erste Erfahrungen mit einem Monorail-Stent-Ballon-System zur endovaskulaeren Behandlung von Nierenarterienstenosen

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Huelsbeck, S.; Jahnke, T.; Grimm, J.; Behm, C.; Hilbert, C.; Frahm, C.; Biederer, J.; Brossmann, J.; Heller, M. [Kiel Univ. (Germany). Klinik fuer Diagnostische Radiologie

    2002-03-01

    Objective: To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). Patients and Methods: During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink{sup TM} 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfermoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88% {+-}10 and 9 mm {+-}5. Results: Renal stent implantation was technically successful in all cases (100%). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg {+-} 10 before to 1 mmHg {+-} 1.8 after the procedure. Remaining stenosis measured 0.7% {+-}4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n.s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p <0.0001) after the intervention. Primary and secondary patency rates at 6 months were 72% (Standard Error 9.8%) and 77% (Standard Error 9.2%), respectively. Conclusion: With the used monorail-stend-balloon device a technically easy, secure and exact renal stent placement is guaranteed, patency rates are similar to those described in the current literature. (orig.) [German] Ziel: Bestimmung der Wertigkeit eines Monorail-Stent-Ballon-Systems zur Behandlung von Nierenarterienstenosen (NAS). Patienten und Methode: Waehrend eines Zeitraumes von 18 Monaten wurden bei 38 Patienten 41 NAS (Hypertonus n = 36, renale Insuffizienz n = 18) mit Indikationen zur renalen Stentimplantation (kalzifizierte Ostiumlaesion n = 35, insuffiziente PTA n = 4, Dissektion n = 2) in die prospektive Untersuchung einbezogen. Vormontierte Stents wurden (Rx-Herculink{sup TM} 5 mm = 13, 6 mm = 34, 7 mm = 1) ueber einen

  18. Cost-Effectiveness of Solitaire Stent Retriever Thrombectomy for Acute Ischemic Stroke: Results From the SWIFT-PRIME Trial (Solitaire With the Intention for Thrombectomy as Primary Endovascular Treatment for Acute Ischemic Stroke).

    Science.gov (United States)

    Shireman, Theresa I; Wang, Kaijun; Saver, Jeffrey L; Goyal, Mayank; Bonafé, Alain; Diener, Hans-Christoph; Levy, Elad I; Pereira, Vitor M; Albers, Gregory W; Cognard, Christophe; Hacke, Werner; Jansen, Olav; Jovin, Tudor G; Mattle, Heinrich P; Nogueira, Raul G; Siddiqui, Adnan H; Yavagal, Dileep R; Devlin, Thomas G; Lopes, Demetrius K; Reddy, Vivek K; du Mesnil de Rochemont, Richard; Jahan, Reza; Vilain, Katherine A; House, John; Lee, Jin-Moo; Cohen, David J

    2017-02-01

    Clinical trials have demonstrated improved 90-day outcomes for patients with acute ischemic stroke treated with stent retriever thrombectomy plus tissue-type plasminogen activator (SST+tPA) compared with tPA. Previous studies suggested that this strategy may be cost-effective, but models were derived from pooled data and older assumptions. In this prospective economic substudy conducted alongside the SWIFT-PRIME trial (Solitaire With the Intention for Thrombectomy as Primary Endovascular Treatment for Acute Ischemic Stroke), in-trial costs were measured for patients using detailed medical resource utilization and hospital billing data. Utility weights were assessed at 30 and 90 days using the EuroQol-5 dimension questionnaire. Post-trial costs and life-expectancy were estimated for each surviving patient using a model based on trial data and inputs derived from a contemporary cohort of ischemic stroke survivors. Index hospitalization costs were $17 183 per patient higher for SST+tPA than for tPA ($45 761 versus $28 578; Pacute ischemic stroke enrolled in the SWIFT-PRIME trial, SST increased initial treatment costs, but was projected to improve quality-adjusted life-expectancy and reduce healthcare costs over a lifetime horizon compared with tPA. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01657461. © 2016 American Heart Association, Inc.

  19. A regenerative approach towards mucosal fenestration closure.

    Science.gov (United States)

    Gandi, Padma; Anumala, Naveen; Reddy, Amarender; Chandra, Rampalli Viswa

    2013-06-06

    Mucosal fenestration is an opening or an interstice through the oral mucosa. A lesion which occurs with greater frequency than generally realised, its occurrence is attributed to a myriad of causes. Mucogingival procedures including connective tissue grafts, free gingival grafts and lateral pedicle grafts are generally considered to be the treatment of choice in the closure of a mucosal fenestration. More often, these procedures are performed in conjunction with other procedures such as periradicular surgery and with bone grafts. However, the concomitant use of gingival grafts and bone grafts in mucosal fenestrations secondary to infections in sites exhibiting severe bone loss is highly debatable. In this article, we report two cases of mucosal fenestrations secondary to trauma and their management by regenerative periodontal surgery with the placement of guided tissue regeneration membrane and bone graft. The final outcome was a complete closure of the fenestration in both the cases.

  20. Aortic aneurysm repair - endovascular

    Science.gov (United States)

    EVAR; Endovascular aneurysm repair - aorta; AAA repair - endovascular; Repair - aortic aneurysm - endovascular ... Endovascular aortic repair is done because your aneurysm is very large, growing quickly, or is leaking or bleeding. You may have ...

  1. Lumbar disc excision through fenestration

    Directory of Open Access Journals (Sweden)

    Sangwan S

    2006-01-01

    Full Text Available Background : Lumbar disc herniation often causes sciatica. Many different techniques have been advocated with the aim of least possible damage to other structures while dealing with prolapsed disc surgically in the properly selected and indicated cases. Methods : Twenty six patients with clinical symptoms and signs of prolapsed lumbar intervertebral disc having radiological correlation by MRI study were subjected to disc excision by interlaminar fenestration method. Results : The assessment at follow-up showed excellent results in 17 patients, good in 6 patients, fair in 2 patients and poor in 1 patient. The mean preoperative and postoperative Visual Analogue Scores were 9.34 ±0.84 and 2.19 ±0.84 on scale of 0-10 respectively. These were statistically significant (p value< 0.001, paired t test. No significant complications were recorded. Conclusion : Procedures of interlaminar fenestration and open disc excision under direct vision offers sufficient adequate exposure for lumbar disc excision with a smaller incision, lesser morbidity, shorter convalescence, early return to work and comparable overall results in the centers where recent laser and endoscopy facilities are not available.

  2. 椎动脉起始部粥样硬化性狭窄患者血管内支架置入术后再狭窄的危险因素研究%Risk Factors of Restenosis in Postoperative Patients with Atherosclerotic Vertebral Artery Origin Stenosis Treated by Endovascular Stent Implantation

    Institute of Scientific and Technical Information of China (English)

    张广玉

    2016-01-01

    目的:探讨椎动脉起始部粥样硬化性狭窄患者血管内支架置入术后再狭窄的危险因素。方法选择沧州市人民医院2013年1月—2015年6月收治的椎动脉起始部粥样硬化性狭窄患者64例,均行血管内支架置入术并随访6个月,记录其性别、年龄、合并症、吸烟史、病变部位、术前椎动脉直径、支架类型、支架直径、支架长度及术后狭窄长度,分析血管内支架置入术后再狭窄的危险因素。结果所有患者顺利完成血管内支架置入术,随访期间18例出现再狭窄(再狭窄组),46例未出现再狭窄(无再狭窄组),再狭窄发生率为28.1%。两组患者性别、年龄、高血压发生率、糖尿病发生率、高胆固醇血症发生率、病变部位、支架直径、支架长度及术后狭窄长度比较,差异无统计学意义(P ﹥0.05);再狭窄组患者吸烟史阳性率高于无再狭窄组,术前椎动脉直径短于无再狭窄组,采用药物支架者所占比例低于无再狭窄组(P ﹤0.05)。多因素 logistic 回归分析结果显示,有吸烟史〔β=0.098,OR =2.648,95%CI(1.159,4.674),P =0.001〕、术前椎动脉直径〔β=0.956,OR =2.614,95% CI(1.134,6.022),P =0.007〕为椎动脉起始部粥样硬化性狭窄患者血管内支架置入术后再狭窄的危险因素,药物支架〔β=-0.612,OR =1.837,95% CI(1.086,4.597),P =0.029〕为保护因素。结论椎动脉起始部粥样硬化性狭窄患者血管内支架置入术后再狭窄发生率较高,有吸烟史、术前椎动脉直径为血管内支架置入术后再狭窄的危险因素,药物支架为保护因素。%Objective To investigate the risk factors of restenosis in postoperative patients with atherosclerotic vertebral artery origin stenosis treated by endovascular stent implantation. Methods A total of 64 patients with atherosclerotic vertebral artery origin stenosis were selected in

  3. The clinical value of endovascular stent in treatment of hepatic vein-type Budd-Chiari syndrome:a Meta analysis%血管内支架治疗肝静脉型布加综合征临床价值的Meta分析

    Institute of Scientific and Technical Information of China (English)

    马强; 余朝文; 任佩; 孙喆

    2016-01-01

    目的:荟萃分析血管内支架在治疗肝静脉型布加综合征中的临床价值。方法采用Newcastle-Ottawa Scale评价方法,通过计算机检索并收集国内外关于肝静脉型布加综合征血管内支架治疗的文献,检索时限为1992年1月—2014年7月,对收集到的资料进行总结,并对血管内支架与单纯性球囊扩张术后再狭窄率、闭塞率进行Meta分析。结果按照检索策略进行系统的检索后,依照纳入标准,最终纳入6篇中文文献,1篇英文文献,共计534例病例。 Meta分析结果显示,对单纯性球囊扩张与血管内支架置入术后再狭窄、闭塞结果进行合并,异质性检验显示有明显的异质性(χ2=15.821, P0.05),血管内支架与单纯性球囊扩张在术后近、中期再狭窄、闭塞率差异均无统计学意义(P值均>0.05)。结论肝静脉型布加综合征采用血管内支架与单纯性球囊扩张术治疗,术后近、中期再狭窄、闭塞率无差异,对于单纯性球囊扩张效果不明显或需多次扩张的患者可考虑行血管内支架置入治疗。%Objective To analyze the clinical significance of endovascular stents in treatment of hepatic vein type Budd-Chiari syndrome. Methods Newcastle-Ottawa Scale assessment method was used by carrying out the computer-based retrieval and collecting the documents about the endovascular stents in treatment of hepatic vein type Budd-Chiari syndrome at home and abroad, the searching time limit was set from January 1992 to July 2014, all of collected data were analyzed and summarized, and the Meta analysis was conducted for the diameter stenosis and blocking rate of postoperative endovascular stents and percutaneous transluminal angioplasty. Results After systematic retrieval based on search strategies, according to inclusion criteria, there were 6 Chinese papers and one English paper included, with a total of 534 patients. The Meta analysis was conducted for the diameter stenosis and blocking rate

  4. 益气活血法预防糖尿病足腔内介入后再狭窄的观察%Clinical Observation of Yiqihuoxue Therapy on Preventing Diabetic Endovascular Stent Restenosis Foot

    Institute of Scientific and Technical Information of China (English)

    李强; 于宗学; 苗进

    2014-01-01

    目的:观察益气活血法预防糖尿病足腔内介入后再狭窄的临床疗效。方法:选择接受腔内治疗的糖尿病足患者370例,分为中药组与对照组,其中中药组185例,对照组185例。所有患者都给予抗血小板药物口服,中药组予益气活血法辨证加减口服中药。观察两组患者术后24个月间歇性跛行、静息痛、踝肱指数(ABI)、肢体再次溃疡或者坏疽及截肢等情况,并进行统计学分析。结果:24个月后,对照组中,1例患者膝下截肢,1例患者膝上截肢,1例患者出现左足趾溃疡,1例患者出现左足趾坏疽,中药组中仅出现1例左足趾坏疽。其中中药组再次出现间歇性跛行、静息痛症状均少于对照组(P<0.01),中药组ABI明显高于对照组(P<0.05)。结论:益气活血法可明显提高糖尿病足腔内治疗术后血管通畅率,改善肢体缺血症状。%Objective:To observe the clinical effects of Yiqihuoxue therapy on preventing diabetic endovascular stent restenosis foot. Methods: 370 diabetic foot (DF) that successfully underwent endovascular therapy were randomly divided into two groups,the control group and the treatment group,185 in each group. Patients in the control group received antiplatelet treatment,while the treatment group was additionally Yiqihuoxue herbal medicine. Ankle brachial index (ABI),intermittent claudication,rest pain,ulcer,gangrene and the incidence of amputation in the following 24 months were recorded and observed in the two groups. Statistical analysis and comparison of observation was carried out with SPSS17.0. Results: After 24 months, in the control group, 1 patient received an above the knee amputation, 1 patient received an below the knee amputation, 1 patient had ulcer in his left foot,1 patient had gangrene with his left foot. In the treatment group, only 1 patient had gangrene in his left foot without amputation. Compared to the control group

  5. Emerging Stent and Balloon Technologies in the Femoropopliteal Arteries

    Directory of Open Access Journals (Sweden)

    Georgios Pastromas

    2014-01-01

    Full Text Available Endovascular procedures for the management of the superficial femoral (SFA and popliteal artery disease are increasingly common. Over the past decade, several stent technologies have been established which may offer new options for improved clinical outcomes. This paper reviews the current evidence for SFA and popliteal artery angioplasty and stenting, with a focus on randomized trials and registries of nitinol self-expanding stents, drug-eluting stents, dug-coated balloons, and covered stent-grafts. We also highlight the limitations of the currently available data and the future routes in peripheral arterial disease (PAD stent and balloon technology.

  6. New devices for a better endovascular approach.

    Science.gov (United States)

    Bosiers, M; Deloose, K; Callaert, J; Maene, L; Beelen, R; Keirse, K; Verbist, J; Peeters, P

    2013-12-01

    The endovascular approach has known a great evolution in terms of vessel patency and treatment possibilities. Longer and more complex lesions with a difficult anatomy can be addressed by a range of endovascular tools. However, to maintain the patency of the treated lesion is the true challenge. In order to fulfill these long-term expectations, newer devices have been developed. The drug-coated balloon combines local drug uptake with no residual material after treatment. To maintain patency and prevent recoil of the arterial wall, the drug-eluting stent has been created to offer stent support with an antiproliferative drug. The main drawbacks of the drug-coated balloon and the drug-eluting stent are being addressed by the drug-eluting absorbable scaffold. The initial scaffolding support in combination with the drug release during a prolonged period, poses the same advantages while the scaffold is being metabolized over time. This continuing evolution in endovascular tools paves the way to an endovascular treatment for the majority of peripheral artery diseases.

  7. Endovascular management of carotid-cavernous fistulas

    Institute of Scientific and Technical Information of China (English)

    GAO Bu-lang; LI Ming-hua; LI Yong-dong; FANG Chun; WANG Jue; DU Zhuo-ying

    2007-01-01

    Objective To investigate endovascular treatment of traumatic direct carotid-cavernous fistulas (CCF) and their complications such as pseudoaneurysms. Methods: Over a five-year period, 22 patients with traumatic direct CCFs were treated endovascularly in our institution. Thirteen patients were treated once with the result of CCF occluded, 8 twice and 1 three times. Treatment modalities included balloon occlusion of the CCF, sacrifice of the ipsilateral internal carotid artery with detachable balloon, coil embolization of the cavernous sinus and secondary pseudoaneurysms, and covered-stent management of the pseudoaneurysms. Results All the direct CCFs were successfully managed endovascularly. Four patients developed a pseudoaneurysm after the occlusion of the CCF with an incidence of pseudoaneurysm formation of 18.2% (4/22). A total number of 8 patients experienced permanent occlusion of the ICA with a rate of ICA occlusion reaching 36.4% (8/22). Followed up through telephone consultation from 6 months to 5 years, all did well with no recurrence of CCF symptoms and signs. Conclusion Traumatic direct CCFs can be successfully managed with endovascular means. The pseudoaneurysms secondary to the occlusion of the CCFs can be occluded with stent-assisted coiling and implantation of covered stents.

  8. Endovascular treatment of symptomatic intracranial atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Syed I Hussain

    2011-02-01

    Full Text Available Abstract: Symptomatic intracranial atherosclerotic disease (ICAD is responsible for approximately 10% of all ischemic strokes in the United States. The risk of recurrent stroke may be as high as 35% in patient with critical stenosis greater than 70% in diameter narrowing. Recent advances in medical and endovascular therapy have placed ICAD at the forefront of clinical stroke research to optimize the best medical and endovascular approach to treat this important underlying stroke etiology. Analysis of symptomatic ICAD studies lead to the question that whether angioplasty and or stenting is a safe, suitable and efficacious therapeutic strategy in patients with critical stenoses that are deemed refractory to medical management. Most of the currently available data in support of angioplasty and or stenting in high risk patients with severe symptomatic ICAD is in the form of case series and randomized trial results of endovascular therapy versus medical treatment are awaited. This is a comprehensive review of the state of the art in the endovascular approach with angioplasty and or stenting of symptomatic intracranial atherosclerotic disease.

  9. Novel stents for the prevention of restenosis.

    Science.gov (United States)

    McKenna, C J; Holmes, D R; Schwartz, R S

    1997-10-01

    Since the introduction of Interventional Cardiology in 1976, there has been rapid expansion both in its clinical application and the tools of the trade. This growth was accelerated with the introduction of the intra-coronary stent in 1987. The demonstration that stents may reduce the incidence of restenosis after percutaneous coronary revascularization has further stimulated the search for the perfect endovascular prosthesis. By creating a hybrid stent, incorporating natural coatings and local drug delivery in the design, it is hoped that the complications associated with stent thrombosis and restenosis can be eradicated. (Trends Cardiovasc Med 1997;7:245-249). © 1997, Elsevier Science Inc.

  10. Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents.

    Science.gov (United States)

    Cohen, José E; Gomori, John Moshe; Moscovici, Samuel; Leker, Ronen R; Itshayek, Eyal

    2014-07-01

    We assessed the frequency and severity of changes in stent configuration and location after the treatment of intracranial aneurysms, and patterns of in-stent stenosis. We retrospectively reviewed data for consecutive aneurysm patients managed with endovascular implantation of flow-diverter stents (Silk Flow Diverter [Balt Extrusion, Montmorency, France] and Pipeline Embolization Device [ev3/Coviden, Minneapolis, MN, USA]) from October 2011 to July 2012. Routine 2, 6, 9-12, and 16-20 month follow-up angiograms were compared, with a focus on changes in stent configuration and location from immediately after deployment to angiographic follow-up, and the incidence and development of in-stent stenosis. Thirty-four patients with 42 aneurysms met inclusion criteria. The Silk device was implanted in 16 patients (47%, single device in 15), the Pipeline device in 18 (53%, single device in 16). On first follow-up angiography, in-stent stenosis was observed in 38% of Silk devices and 39% of Pipeline devices. In-stent stenosis was asymptomatic in 12 of 13 patients. One woman presented with transient ischemic attacks and required stent angioplasty due to end tapering and mild, diffuse in-stent stenosis. Configuration and location changes, including stent creeping and end tapering were seen in 2/16 patients (13%) with Silk devices, and 0/18 patients with Pipeline devices. We describe stent creeping and end tapering as unusual findings with the potential for delayed clinical complications. In-stent stenosis, with a unique behavior, is a frequent angiographic finding observed after flow-diverter stent implant. The stenosis is usually asymptomatic; however, close clinical and angiographic monitoring is mandatory for individualized management. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Reperfusion hemorrhage following superior mesenteric artery stenting.

    LENUS (Irish Health Repository)

    Moore, Michael

    2012-02-03

    Percutaneous transluminal angioplasty and stent placement is now an established treatment option for chronic mesenteric ischemia and is associated with low mortality and morbidity rates. We present a case of reperfusion hemorrhage complicating endovascular repair of superior mesenteric artery stenosis. Although a recognized complication following repair of carotid stenosis, hemorrhage has not previously been reported following mesenteric endovascular reperfusion. We describe both spontaneous cessation of bleeding and treatment with coil embolization.

  12. Refining stent technologies for femoral interventions.

    Science.gov (United States)

    Bosiers, M; Deloose, K; Callaert, J; Maene, L; Keirse, K; Verbist, J; Peeters, P

    2012-08-01

    Stents were created as a mechanical scaffold to prevent vessel recoil and luminal renarrowing after percutaneous transluminal angioplasty (PTA). In femoropopliteal arteries, indication for stent implantation remains a topic much debated on, especially in long lesion configurations. Ever since the first stents were introduced on the market, in-stent restenosis (ISR) has been an important issue. The evolution in stent design has known a major progression in the last decades from the first generation of stents, plagued with high fracture rates and low primary patency rates, to the design of newer stents to tackle these outcomes. More flexible and longer stents decreased the high fracture rates and drug-eluting stents offered a solution to the restenosis rates by local drug application. The difficult recrossibility of the lesion because of the presence of a permanent vascular scaffold is an obstacle that the drug-coated balloon (DCB) overcomes. Future perspectives in the treatment of femoropopliteal lesions are found in the bioresorbable stent implantation. The bioresorbable stent combines the advantages of a drug-eluting scaffolding stent without the remainder of a foreign object in the long-term. Further investigations in this area will eventually evolve in the creation of a superior endovascular treatment modality with high long-term patency rates and minimal detriments.

  13. A numerical framework for the mechanical analysis of dual-layer stents in intracranial aneurysm treatment.

    Science.gov (United States)

    Alherz, Ali I; Tanweer, Omar; Flamini, Vittoria

    2016-08-16

    Dual-layer stents and multi-layer stents represent a new paradigm in endovascular interventions. Multi-layer stents match different stent designs in order to offer auxiliary functions. For example, dual-layer stents used in the endovascular treatment of intracranial aneurysms, like the FRED(TM) (MicroVention, CA) stent, combine a densely braided inner metallic mesh with a loosely braided outer mesh. The inner layer is designed to divert blood flow, whereas the outer one ensures microvessels branching out of the main artery remain patent. In this work, the implemented finite element (FE) analysis identifies the key aspects of dual-stent mechanics. In particular, dual-layer stents used in the treatment of intracranial aneurysms require the ability to conform to very narrow passages in their closed configuration, while at the same time they have to provide support and stability once deployed. This study developed a numerical framework for the analysis of dual-layer stents for endovascular intracranial aneurysm treatment. Our results were validated against analytical methods. For the designs considered, we observed that foreshortening was in average 37.5%±2.5%, and that doubling the number of wires in the outer stent increased bending moment by 23%, while halving the number of wires of the inner stent reduced von Mises stress by 2.3%. This framework can be extended to the design optimization of multi-layer stents used in other endovascular treatments.

  14. Endovascular Device Testing with Particle Image Velocimetry Enhances Undergraduate Biomedical Engineering Education

    Science.gov (United States)

    Nair, Priya; Ankeny, Casey J.; Ryan, Justin; Okcay, Murat; Frakes, David H.

    2016-01-01

    We investigated the use of a new system, HemoFlow™, which utilizes state of the art technologies such as particle image velocimetry to test endovascular devices as part of an undergraduate biomedical engineering curriculum. Students deployed an endovascular stent into an anatomical model of a cerebral aneurysm and measured intra-aneurysmal flow…

  15. Application of endovascular exclusion in treatment of ruptured abdominal aortic aneurysm%腔内隔绝术在破裂性腹主动脉瘤治疗中的应用

    Institute of Scientific and Technical Information of China (English)

    张天华; 姜维良; 张英男; 孙占峰; 马军

    2011-01-01

    [Objective] To summarize clinical practice of endovascular exclusion in patients with ruptured abdominal aortic aneurysms. [Methods] From January 2005 to March 2011, 16 cases of abdominal aortic aneurysm were treated with endovascular exclusion in the Second Affiliated Hospital of Harbin Medical University. Their diagnosis was confirmed by digital subtraction angiography (DSA) and spiral computed tomography angiography. In order to isolate the body of abdominal aortic aneurysm from blood flow, under the guidance of DSA, stent graft was introduced into the abdominal aorta from a small incision of the femoral artery. [ Results] Sixteen cases of abdominal aortic aneurysm were performed endovascular exclusion successfully, including two cases of fenestrations of stent. Two cases died after the procedures, with fatality rate at 12.5% , in whom one died of rupture of abdominal aortic aneurysm and another died of septic shock. Internal fistula was occurred in three patients, but sealed one month after surgery. [Conclusion] Endovascular exclusion of abdominal aortic aneurysm is safe and feasible. The indications of endovascular exclusion of aortic aneurysms and skills of interventional procedure are key factors of successful operation.%[目的]总结腔内隔绝术治疗破裂性腹主动脉瘤的经验.[方法]收集2005年1月-2011年3月采用腔内隔绝术治疗破裂性腹主动脉瘤的16例患者的临床资料.所有患者行数字减影血管造影(DSA)和/或螺旋CT血管成像检查确诊.在DSA指导下,经股动脉小切口将支架移植物导入腹主动脉内,从腔内将瘤体与血流隔绝.[结果] 16例腹主动脉瘤腔内隔绝术获成功.术后死亡2例(病死率为12.5%),分别死于瘤体破裂和感染性休克.3例患者发生内瘘,1个月后自行封闭.[结论]腹主动脉瘤腔内隔绝术是安全有效的方法,其治疗成功的关键主要在于了解动脉瘤的解剖形态以及操作的准确和熟练.

  16. Endovascular Repair of a Ruptured Descending Thoracic Aortic Aneurysm

    Science.gov (United States)

    DeFrain, Michael; Strickman, Neil E.; Ljubic, Branimir J.; Dougherty, Kathryn G.; Gregoric, Igor D.

    2006-01-01

    Endovascular aneurysm repair has considerable potential advantages over the surgical approach as a treatment for thoracic aortic rupture, in part because open surgical repair of ruptured thoracic aortic aneurysms is associated with high mortality and morbidity rates. We describe the successful endovascular deployment of stent-grafts to repair a contained rupture of a descending thoracic aortic aneurysm in an 86-year-old man whose comorbidities prohibited surgery. Two months after the procedure, magnetic resonance angiography showed a patent stent-graft, a patent left subclavian artery, and complete exclusion of the aneurysm. PMID:16878637

  17. Stent migration during transcatheter management of coarctation of aorta.

    Science.gov (United States)

    Kannan, Bhava R J; Srinivasan, Muthusamy

    2012-02-15

    A 13-year-old girl underwent endovascular stent placement for coarctation of aorta. The fully expanded stent migrated to ascending aorta which could be stabilized, recrimped, and repositioned with a 20-mm goose neck snare. Postdilatation was performed from the left brachial route resulting in a good outcome.

  18. Long term results of kissing stents in the aortic bifurcation

    NARCIS (Netherlands)

    Hinnen, J.W.; Konickx, M.A.; Meerwaldt, Robbert; Kolkert, J.L.P.; van der Palen, Jacobus Adrianus Maria; Huisman, A.B.

    2015-01-01

    BACKGROUND: To evaluate the long-term outcome after aortoiliac kissing stent placement and to analyze variables, which potentially influence the outcome of endovascular reconstruction of the aortic bifurcation. METHODS: All patients treated with aortoiliac kissing stents at our institution between

  19. Long-Term Type 1 Diabetes Enhances In-Stent Restenosis after Aortic Stenting in Diabetes-Prone BB Rats

    NARCIS (Netherlands)

    Onuta, Geanina; Groenewegen, Hendrik C.; Klatter, Flip A.; Boer, Mark Walther; Goris, Maaike; van Goor, Harry; Roks, Anton J. M.; Rozing, Jan; de Smet, Bart J. G. L.; Hillebrands, Jan-Luuk

    2011-01-01

    Type 1 diabetic patients have increased risk of developing in-stent restenosis following endovascular stenting. Underlying pathogenetic mechanisms are not fully understood partly due to the lack of a relevant animal model to study the effect(s) of long-term autoimmune diabetes on development of in-s

  20. Paraffin processing of stented arteries using a postfixation dissolution of metallic and polymeric stents.

    Science.gov (United States)

    Fishbein, Ilia; Welch, Tre; Guerrero, David T; Alferiev, Ivan S; Adamo, Richard F; Chorny, Michael; Gupte, Rohit K; Tang, Yanqing; Levy, Robert J

    Studying the morphology of the arterial response to endovascular stent implantation requires embedding the explanted stented artery in rigid materials such as poly(methyl methacrylate) to enable sectioning through both the in situ stent and the arterial wall, thus maintaining the proper anatomic relationships. This is a laborious, time-consuming process. Moreover, the technical quality of stained plastic sections is typically suboptimal and, in some cases, precludes immunohistochemical analysis. Here we describe a novel technique for dissolution of metallic and plastic stents that is compatible with subsequent embedding of "destented" arteries in paraffin, fine sectioning, major staining protocols, and immunohistochemistry.

  1. Fenestrations of the intracranial vertebrobasilar system diagnosed by MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Uchino, Akira; Saito, Naoko; Okada, Yoshitaka; Kozawa, Eito; Nishi, Naoko; Mizukoshi, Waka; Inoue, Kaiji; Nakajima, Reiko; Takahashi, Masahiro [Saitama Medical University International Medical Center, Department of Diagnostic Radiology, Saitama (Japan)

    2012-05-15

    Fenestrations of cerebral arteries are most common in the vertebrobasilar (VB) system, and magnetic resonance (MR) angiographic studies of these variations are sparse. We retrospectively reviewed MR angiographic images of 3,327 patients; images were obtained using two 1.5-T imagers and picked up fenestrations of the intracranial vertebral artery (VA), VB junction, and basilar artery (BA) for evaluation. In 92 patients, we found 93 fenestrations (2.80%), which included 18 of the intracranial VA (0.54% prevalence), 6 of the VB junction (0.18%), and 69 of the BA (2.07%). Most VA fenestrations were large, and the posterior inferior cerebellar artery arose from the fenestrated segment in 10 patients (56%). Fenestrations of the VB junction were small and triangular. Sixty-five (94%) of the 69 BA fenestrations were located at the proximal segment and had small slit-like configurations. The anterior inferior cerebellar artery arose from the fenestrated segment in 27 patients (37%). We found 18 cerebral aneurysms in 16 (17%) of the 92 patients with fenestration but detected only one aneurysm at the fenestration. The overall prevalence of fenestrations of the intracranial VB system was 2.77%. We found associated cerebral aneurysms relatively frequently but rarely at the fenestration. (orig.)

  2. [Endovascular repair for coarctation of the aorta in an adult].

    Science.gov (United States)

    Hayashi, Jun; Abe, Kazuo; Hata, Masaki; Nagano, Naoko; Hamasaki, Azumi; Suzuki, Kenji

    2013-09-01

    A 27-year-old woman with Turner's syndrome who underwent successful endovascular treatment for coarctation of the aorta is presented. She was admitted to our hospital complaining of upper extremity hypertension. Computed tomography revealed discrete stenosis of the proximal descending aorta and developed collateral circulation. After endovascular repair with a balloon expandable stent, her transcoarctation gradient fell from 44 mmHg preoperatively to less than 10 mmHg. She was discharged with no complications on the 7th postoperative day. Coarctation of the aorta in an adult patient could be safely and effectively managed by endovascular treatment.

  3. Fenestral otosclerosis: significance of preoperative CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Swartz, J.D.; Faerber, E.N.; Wolfson, R.J.; Marlowe, F.I.

    1984-06-01

    Thirty-five consecutive patients with the clinical diagnosis of fenestral otosclerosis were evaluated with high-resolution computed tomography (CT). Twenty-six were diagnosed as having this disorder by CT evidence of abnormal bony excrescences at or adjacent to the oval window. Sections were also evaluated for evidence of plaque formation elsewhere in the lateral wall of the labyrinth and for surgical obstacles such as an abnormally wide cochlear aqueduct, a high jugular vein, and a dehiscent facial nerve. It is concluded that fenestral otosclerosis may be accurately diagnosed with proper CT techniques.

  4. Fenestration System Performance Research, Testing, and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jim Benney

    2009-11-30

    The US DOE was and is instrumental to NFRC's beginning and its continued success. The 2005 to 2009 funding enables NFRC to continue expanding and create new, improved ratings procedures. Research funded by the US DOE enables increased fenestration energy rating accuracy. International harmonization efforts supported by the US DOE allow the US to be the global leader in fenestration energy ratings. Many other governments are working with the NFRC to share its experience and knowledge toward development of their own national fenestration rating process similar to the NFRC's. The broad and diverse membership composition of NFRC allows anyone with a fenestration interest to come forward with an idea or improvement to the entire fenestration community for consideration. The NFRC looks forward to the next several years of growth while remaining the nation's resource for fair, accurate, and credible fenestration product energy ratings. NFRC continues to improve its rating system by considering new research, methodologies, and expanding to include new fenestration products. Currently, NFRC is working towards attachment energy ratings. Attachments are blinds, shades, awnings, and overhangs. Attachments may enable a building to achieve significant energy savings. An NFRC rating will enable fair competition, a basis for code references, and a new ENERGY STAR product category. NFRC also is developing rating methods to consider non specular glazing such as fritted glass. Commercial applications frequently use fritted glazing, but no rating method exists. NFRC is testing new software that may enable this new rating and contribute further to energy conservation. Around the world, many nations are seeking new energy conservation methods and NFRC is poised to harmonize its rating system assisting these nations to better manage and conserve energy in buildings by using NFRC rated and labeled fenestration products. As this report has shown, much more work needs to be

  5. Stent-graft repair of carotid endarterectomy-related pseudoaneurysm

    Institute of Scientific and Technical Information of China (English)

    Manuela Carnini; Gabriele Piffaretti; Chiara Lomazzi

    2013-01-01

    Objective: Carotid endarterectomy-related pseudoaneurysms are rare lesions challenging to be treated with conventional open surgery. Endovascular stent-graft has been rarely adopted with encouraging results. We present a case of a huge carotid pseudoaneurysm treated with a stent-graft and managed with a stent-graft and reviewed the available literature on the management and results of this technique for these challenging lesions.

  6. Endovascular Management of May-Thurner Syndrome

    Science.gov (United States)

    Al Safran, Zakareya; Hasan, Hosam; Zeid, Wael Abu

    2012-01-01

    May-Thurner syndrome or iliac vein compression syndrome is associated with deep vein thrombosis (DVT) resulting from chronic compression of the left iliac vein against lumbar vertebrae by the overlying right common iliac artery. Historically, May-Thurner syndrome has been treated with anticoagulation therapy. However, this therapy can be problematic when given alone, because it prevents the propagation of the thrombus without eliminating the existing clot. Furthermore, it does not treat the underlying mechanical compression. Consequently, syndrome who was managed by anticoagulation therapy alone, there is a significant chance that the patient will develop recurrent deep vein thrombosis or post thrombotic syndrome or both. Recently, both retrospective and prospective studies have suggested that endovascular management should be front-line treatment; endovascular management actively treats both the mechanical compression with stent placement and the thrombus burden with chemical dissolution. We report our case of 53 years old male patient with May Thurner syndrome who managed by endovascular treatment. PMID:23555515

  7. [Short and long-term results of endovascular treatment of bifurcational coronary stenosis].

    Science.gov (United States)

    Shugushev, Z Kh; Movsesiants, M Iu; Maksimkin, D A; Baranovich, V Iu; Faĭbushevich, A G; Stefanov, S A; Tarichko, Iu V

    2010-01-01

    Short and long-term results of endovascular treatment of true bifurcational coronary stenosis were analyzed in 229 patients. 68 patients received a "provisional-T" stenting on the first stage of the study. On the next stage 40 patients received the same "provisional-T" stenting, a total bifurcational stenting was conducted in 37 patients. Only coated stents were used. Independent risk factors of "provisional-T" stenting conversion to total bifurcational stenting were revealed. There were no differences between "provisional-T" and total bifurcational stenting considering the short-term treatment results. Long-term results (12-18 months) were analyzed in 70 patients. There were no restenosis of the main artery, whereas restenosis of the lateral branch was noticed in 5.5 and 2.94%, respectively, in the groups of "provisional-T" and total bifurcational stenting. Late thrombosis was registered in 1 case from the group of total bifurcational stenting.

  8. Clinical evaluation of percutaneous endovascular stent implantation on patients with subclavian artery steal blood syndrome%经皮血管内支架植入治疗锁骨下动脉盗血综合征的临床疗效

    Institute of Scientific and Technical Information of China (English)

    赵小妹; 刘永刚; 赵静; 许云鹤; 曹姗; 任翠剑

    2014-01-01

    Objective To evaluate the short-term and long-term clinical efficacy of per-cutaneous endovascular stent implantation in the treatment of subclavian artery steal blood syndrome (SSS).Methods A total of 28 SSS patients treated in our hospital from January 2010 to January 2012 were selected and given percutaneous endovascular stent implantation as well as transcranial doppler ultrasound (TCD),carotid duplex ultrasound (CDU)and digital subtraction angiography (DSA)before and after treatment.Follow-up was ended in January 2014 to observe the short-term and long-term clinical efficacy.Results Postoperative TCD,CDU and DSA showed positive blood flow in vertebral and basilar arteries and improved clinical symptoms in SSS patients.Only 3 patients were with relevant complications and 2 with recurrence ones at the end of follow-up.Con-clusion Percutaneous endovascular stent implantation is effective and safe in treating SSS with TCD and CDU as its routine therapies for follow-up clinic.%目的:评估经皮血管内支架植入术治疗锁骨下动脉盗血综合征(SSS)的近期和远期临床疗效。方法选取2010年1月-2012年1月在本院就诊的28例 SSS 患者为研究对象,所有患者均行经皮血管内支架植入术,术前及术后均行经颅多普勒超声检查(TCD)、颈部血管彩超(CDU)及脑血管造影(DSA)检查。随访至2014年1月,观察近期及远期临床疗效。结果术后 TCD、CDU 和 DSA 检查显示,患者椎动脉及基底动脉均为正向血流,临床表现为显著改善,仅3例出现相关并发症,至随访结束时,仅2例出现症状复发。结论经皮血管内支架植入术治疗 SSS 有效、安全,且 TCD、CDU 可作为随诊常规手段。

  9. Sub mucous cleft palate with fenestration

    OpenAIRE

    Shah, Sheerin; Garg, Ramneesh; Uppal, Sanjeev K.; Mittal, Rajinder K.

    2014-01-01

    Congenital fenestration in sub mucous cleft palate is not a common identity. This patient is a 16-year-old female who presented with nasal speech. On examination, she had associated microform cleft lip with nasal deformity. Successful palatoplasty with intra velar veloplasty was done.

  10. Personalized design and virtual evaluation of physician-modified stent grafts for juxta-renal abdominal aortic aneurysms

    Science.gov (United States)

    Sanathkhani, Soroosh; Shroff, Sanjeev G.; Menon, Prahlad G.

    2017-02-01

    Endovascular aneurysm repair (EVAR) of juxtarenal aortic aneurysms (JAA) is particularly challenging owing to the requirement of suprarenal EVAR graft fixation, which has been associated with significant declines in long term renal function. Therefore, the ability to design fenestrated EVAR grafts on a personalized basis in order to ensure visceral and renal perfusion, is highly desirable. The objectives of this study are: a) To demonstrate novel 3D geometric methods to virtually design and deploy EVAR grafts into a virtually designed JAA, by applying a custom surface mesh deformation tool to a patient-specific descending aortic model reconstructed from computed tomographic (CT) images; and b) To virtually evaluate patient-specific renal flow and wall stresses in these patient-specific virtually EVAR geometries, using computational fluid dynamics (CFD). The presented framework may provide the modern cardiovascular surgeon the ability to leverage non-invasive, pre-operative imaging equipment to personalize and guide EVAR therapeutic strategy. Our CFD studies revealed that virtual EVAR grafting of a patient-specific JAA, with optimal fenestration sites and renal stenting, led to a 179.67±15.95% and 1051.43±18.34% improvement in right and left renal flow rates, respectively, when compared with the baseline patient-specific aortic geometry with renal stenoses, whereas a right and left renal flow improved by 36.44±2.24% and 885.93±12.41%, respectively, relative to the equivalently modeled JAA with renal stenoses, considering averages across the three simulated inflow rate cases. The proposed framework have utility to iteratively optimize suprarenal EVAR fixation length and achieve normal renal wall shear stresses and streamlined juxtarenal hemodynamics.

  11. Endovascular management of an acquired aortobronchial fistula following aortic bypass for coarctation.

    LENUS (Irish Health Repository)

    O'Sullivan, Katie E

    2013-09-20

    Aortobronchial fistula (ABF) in the setting of aortic coarctation repair is very rare but uniformly fatal if untreated. Endovascular stenting of the descending aorta is now the first-choice approach for ABF presenting with haemoptysis and offers a less-invasive technique with improved outcomes, compared with open repair. We report a case of late ABF occurring following bypass for aortic coarctation. Management focused on two key manoeuvres: use of a covered endovascular stent to occlude the aortic bypass thus controlling the fistula and dilatation and stenting of native coarctation.

  12. Endovascular management of an acquired aortobronchial fistula following aortic bypass for coarctation.

    Science.gov (United States)

    O'Sullivan, Katie E; Bolster, Ferdia; Lawler, Leo P; Hurley, John

    2014-01-01

    Aortobronchial fistula (ABF) in the setting of aortic coarctation repair is very rare but uniformly fatal if untreated. Endovascular stenting of the descending aorta is now the first-choice approach for ABF presenting with haemoptysis and offers a less-invasive technique with improved outcomes, compared with open repair. We report a case of late ABF occurring following bypass for aortic coarctation. Management focused on two key manoeuvres: use of a covered endovascular stent to occlude the aortic bypass thus controlling the fistula and dilatation and stenting of native coarctation.

  13. Carotid Stent Fracture from Stylocarotid Syndrome

    Science.gov (United States)

    Hooker, Jeffrey D; Joyner, David A; Farley, Edward P; Khan, Majid

    2016-01-01

    Eagle syndrome is a rare condition resulting from elongation of the temporal styloid process or calcification of its associated stylohyoid ligaments. Although usually presenting with pain or odynophagia, Eagle syndrome has been reported to cause a multitude of neurologic symptoms or vascular complications, some of which can be life-threatening. We present a case in which an endovascularly placed internal carotid artery stent in close proximity to a calcified stylohyoid ligament resulted in stent fracture with subsequent stent and vessel occlusion. We review and discuss the presentation, diagnosis, etiology, complications and treatment options of the syndrome.

  14. Carotid artery stenting : a 2009 update

    NARCIS (Netherlands)

    Zeebregts, Clark J.; Meerwaldt, Robbert; Geelkerken, Robert H.

    2009-01-01

    Purpose of review Carotid endarterectomy (CEA) is is still considered the gold standard in the treatment of patients with significant carotid stenosis and has proven its value over the past decades. Endovascular techniques have evolved, and carotid artery stenting (CAS) is challenging CEA to become

  15. Endovascular repair of para-anastomotic aortoiliac aneurysms.

    LENUS (Irish Health Repository)

    Tsang, Julian S

    2009-11-01

    The purpose of this study is to evaluate the use of endovascular stent grafts in the treatment of para-anastomotic aneurysms (PAAs) as an alternative to high-risk open surgical repair. We identified all patients with previous open aortic aneurysm repair who underwent infrarenal endovascular aneurysm repair (EVAR) at our institution from June 1998 to April 2007. Patient demographics, previous surgery, and operative complications were recorded. One hundred forty-eight patients underwent EVAR during the study period and 11 patients had previous aortic surgery. Of these 11 redo patients, the mean age was 62 years at initial surgery and 71 years at EVAR. All patients were male. Initial open repair was for rupture in five (45%) patients. The average time between initial and subsequent reintervention was 9 years. All patients were ASA Grade III or IV. Fifty-five percent of the PAAs involved the iliac arteries, 36% the abdominal aorta, and 9% were aortoiliac. Ten patients had endovascular stent-grafts inserted electively, and one patient presented with a contained leak. Aorto-uni-iliac stent-grafts were deployed in seven patients, and bifurcated stent-grafts in four patients. A 100% successful deployment rate was achieved. Perioperative mortality was not seen and one patient needed surgical reintervention to correct an endoleak. Endovascular repair of PAAs is safe and feasible. It is a suitable alternative and has probably now become the treatment of choice in the management of PAAs.

  16. Mechanical design of an intracranial stent for treating cerebral aneurysms.

    Science.gov (United States)

    Shobayashi, Yasuhiro; Tanoue, Tetsuya; Tateshima, Satoshi; Tanishita, Kazuo

    2010-11-01

    Endovascular treatment of cerebral aneurysms using stents has advanced markedly in recent years. Mechanically, a cerebrovascular stent must be very flexible longitudinally and have low radial stiffness. However, no study has examined the stress distribution and deformation of cerebrovascular stents using the finite element method (FEM) and experiments. Stents can have open- and closed-cell structures, and open-cell stents are used clinically in the cerebrovasculature because of their high flexibility. However, the open-cell structure confers a risk of in-stent stenosis due to protrusion of stent struts into the normal parent artery. Therefore, a flexible stent with a closed-cell structure is required. To design a clinically useful, highly flexible, closed-cell stent, one must examine the mechanical properties of the closed-cell structure. In this study, we investigated the relationship between mesh patterns and the mechanical properties of closed-cell stents. Several mesh patterns were designed and their characteristics were studied using numerical simulation. The results showed that the bending stiffness of a closed-cell stent depends on the geometric configuration of the stent cell. It decreases when the stent cell is stretched in the circumferential direction. Mechanical flexibility equal to an open-cell structure was obtained in a closed-cell structure by varying the geometric configuration of the stent cell.

  17. Thoracic Stent Graft Implantation for Aortic Coarctation with Patent Ductus Arteriosus via Retroperitoneal Iliac Approach in the Presence of Small Sized Femoral Artery

    Directory of Open Access Journals (Sweden)

    Ozge Korkmaz

    2016-01-01

    Full Text Available Endovascular stent graft implantation is a favorable method for complex aortic coarctation accompanied by patent ductus arteriosus. Herein, an 18-year-old woman with complex aortic coarctation and patent ductus arteriosus was successfully treated by endovascular thoracic stent graft via retroperitoneal approach. The reason for retroperitoneal iliac approach was small sized common femoral arteries which were not suitable for stent graft passage. This case is the first aortic coarctation plus patent ductus arteriosus case described in the literature which is treated by endovascular thoracic stent graft via retroperitoneal approach.

  18. Aortic Wall Injury Related to Endovascular Therapy for Aortic Coarctation.

    Science.gov (United States)

    Tretter, Justin T; Jones, Thomas K; McElhinney, Doff B

    2015-09-01

    Aortic wall complications can occur in unrepaired aortic coarctation (CoA) and after surgical repair or endovascular treatment. This review summarizes the available literature and current understanding of aortic wall injury (AWI) surrounding the management of CoA, focusing specifically on acute and follow-up AWI after endovascular treatment. There have been 23 reported cases of aortic rupture after endovascular treatment for CoA, including angioplasty alone, bare metal stenting, and primary covered stent therapy. Even if these published cases represent only a minority of ruptures that have actually occurred, the incidence is substantially <1%. The incidence of acute aneurysm formation was 0% to 13% after angioplasty, 0% to 5% after bare metal stent placement, and <1% after covered stent placement. The reported incidence and natural history of both acute and new AWI during follow-up after endovascular therapy for CoA varies considerably, likely secondary to ascertainment and reporting biases and inconsistent definitions. Although important AWI after endovascular treatment of CoA seems to be declining in frequency with increasing experience and improving technology, it remains one of the most important potential adverse outcomes. Long-term surveillance for new AWI and monitoring of existing AWI is mandatory, with institution of appropriate treatment when necessary. A central research focus in this population should be determination of the appropriate treatment for both native and recurrent CoA across various ages with regard to limiting recurrent CoA and preventing associated aortic wall complications, in addition to determining the appropriate treatment of various AWI. Consistent definitions and reporting are necessary to truly understand the incidence of, risk factors for, and measures protective against AWI after angioplasty or stent implantation for CoA.

  19. Microguidewire Looping to Traverse Stented Parent Arteries of Intracranial Aneurysms

    Science.gov (United States)

    Cho, Young Dae; Rhim, Jong Kook; Yoo, Dong Hyun; Kang, Hyun-Seung; Kim, Jeong Eun; Han, Moon Hee

    2017-01-01

    Objective Stents are widely used in coil embolization of intracranial aneurysms, but on occasion, a microcatheter must traverse a stented segment of artery (so-called trans-cell technique) to select an aneurysm, or double stenting may necessary. In such situations, microguidewire passage and microcatheter delivery through a tortuous stented parent artery may pose a technical challenge. Described herein is a microguidewire looping technique to facilitate endovascular navigation in these circumstances. Methods To apply this technique, the microguidewire tip is looped before entering the stented parent artery and then advanced distally past the stented segment, with the loop intact. Rounding of the tip prevents interference from stent struts during passage. A microcatheter is subsequently passed into the stented artery for positioning near the neck of aneurysm, with microguidewire assistance. The aneurysm is then selected, steering the microcatheter tip (via inner microguidewire) into the dome. Results This technique proved successful during coil embolization of nine saccular intracranial aneurysms (internal carotid artery [ICA], 6; middle cerebral artery, 2; basilar tip, 1), performing eight trans-cell deliveries and one additional stenting. Selective endovascular embolization was enabled in all patients, resulting in excellent clinical and radiologic outcomes, with no morbidity or mortality directly attributable to microguidewire looping. Conclusion Microguidewire looping is a reasonable alternative if passage through a stented artery is not feasible by traditional means, especially at paraclinoid ICA sites. PMID:28264249

  20. Evaluation of stent visibility by flat panel detector CT in patients treated for intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Clarencon, Frederic [Groupe Hospitalier Pitie-Salpetriere, Paris (France); Pitie-Salpetriere Hospital, Department of Neuroradiology, Paris (France); Piotin, Michel; Pistocchi, Silvia; Blanc, Raphael [Fondation A. de Rothschild, Paris (France); Babic, Drazenko [Philips Healthcare, Best (Netherlands)

    2012-10-15

    This study aimed to evaluate the visibility of stents using high-resolution computed tomography (CT) acquisitions acquired with flat panel detector (XperCT, Allura series, Philips Healthcare, The Netherlands) for endovascular treatment of intracranial aneurysms. On a 24-month period, 48 patients endovascularly treated by coiling and stenting (59 stents) for intracranial aneurysms were explored by flat panel detector CT technique. A sequence of 620 2D images was acquired over an angle of 240 using a 1,024 x 1,024 pixel matrix detector within a 48-cm field of view. The images were retrospectively analyzed independently by two neuroradiologists. Evaluation criteria were percentage of visualization of the stents and stent deployment (kinking or unsatisfactory deployment of the stent). Evaluation of the stent was feasible for all the patients. Stent visibility by XperCT was overall estimated at 76% of the stent length. Difficulties to analyze the stents were related to coil artifacts but not to packing density or aneurysm location. Stent length visualization was higher when the acquisition was performed before additional coiling (P < 0.0001). Mild kinking/misdeployment was noticed in 22% of the cases. XperCT technique provides multiplanar and 3D reconstructions that allows for a satisfying visualization of intracranial stents. This CT-like acquisition should be performed after the stent deployment and before coiling, in order to obtain better stent visualization. (orig.)

  1. Endovascular treatment of hemodialysis access pseudoaneurysms.

    Science.gov (United States)

    Shah, Aamir S; Valdes, Jaime; Charlton-Ouw, Kristofer M; Chen, Zhongxue; Coogan, Sheila M; Amer, Hammad M; Estrera, Anthony L; Safi, Hazim J; Azizzadeh, Ali

    2012-04-01

    Pseudoaneurysm (PSA) formation is a complication of hemodialysis access. Open repair requires PSA resection, interposition graft placement, and insertion of a catheter as a bridge. Endovascular stent graft repair is an alternative that permits immediate use of the access site. The objective of this study was to determine the efficacy of stent grafts for repair of arteriovenous fistula and arteriovenous graft PSA. A retrospective review of medical records from October 2007 to March 2011 revealed 24 patients with a PSA who underwent endovascular repair using a stent graft. Indications for repair included PSA with symptoms (n = 11), PSA with skin erosion (n = 8), PSA with failed hemodialysis (n = 3), and PSA after balloon angioplasty of a stenosis (n = 2). Outcome measures were technical success, 30-day and 180-day patency, secondary interventions, and complications. All the statistical analyses were conducted by using software SAS 9.1 (SAS, SAS Institute, Gary, NC). Twenty-seven self-expanding stent grafts (Viabahn, W. L. Gore, n = 25; Fluency, Bard, n = 2) were used to treat hemodialysis access (arteriovenous graft, n = 13; arteriovenous fistula, n = 11) PSA in 24 patients (16 females; mean age, 55.7 years; mean body mass index, 28.4; mean PSA diameter, 19.5 mm). Comorbidities included hypertension (n = 22; 91.7%), diabetes mellitus (n = 8; 33.3%), and coronary artery disease (n = 4; 16.67%). The median time from access creation to repair was 455 days. The technical success rate was 100%. Balloon angioplasty of an outflow stenosis was performed in 56% of stent grafts. The 30- and 180-day patency rate was 100% and 69.2%, respectively. Three secondary interventions were performed for treatment of unrelated stenosis. Treatment failure occurred in five (18.5%) stent grafts due to infection (n = 3) and thrombosis (n = 2). Treatment of PSA with skin erosion was associated with failure due to infection (odds ratio, 5.0; 95% confidence interval, .38, 66.01). The remaining

  2. Spontaneous Solitaire™ AB Thrombectomy Stent Detachment During Stroke Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Akpinar, Suha, E-mail: akpinarsuha@hotmail.com; Yilmaz, Guliz, E-mail: glz.yilmaz@hotmail.com [Near East University Hospital, Department of Radiology, Faculty of Medicine (Turkey)

    2015-04-15

    Spontaneous Solitaire™ stent retriever detachment is a rarely defined entity seen during stroke treatment, which can result in a disastrous clinical outcome if it cannot be solved within a critical stroke treatment time window. Two solutions to this problem are presented in the literature. The first is to leave the stent in place and apply angioplasty to the detached stent, while the second involves surgically removing the stent from the location at which it detached. Here, we present a case of inadvertent stent detachment during stroke treatment for a middle cerebral artery M1 occlusion resulting in progressive thrombosis. The detached stent was removed endovascularly by another Solitaire stent, resulting in the recanalization of the occluded middle cerebral artery.

  3. High Performance Commercial Fenestration Framing Systems

    Energy Technology Data Exchange (ETDEWEB)

    Mike Manteghi; Sneh Kumar; Joshua Early; Bhaskar Adusumalli

    2010-01-31

    A major objective of the U.S. Department of Energy is to have a zero energy commercial building by the year 2025. Windows have a major influence on the energy performance of the building envelope as they control over 55% of building energy load, and represent one important area where technologies can be developed to save energy. Aluminum framing systems are used in over 80% of commercial fenestration products (i.e. windows, curtain walls, store fronts, etc.). Aluminum framing systems are often required in commercial buildings because of their inherent good structural properties and long service life, which is required from commercial and architectural frames. At the same time, they are lightweight and durable, requiring very little maintenance, and offer design flexibility. An additional benefit of aluminum framing systems is their relatively low cost and easy manufacturability. Aluminum, being an easily recyclable material, also offers sustainable features. However, from energy efficiency point of view, aluminum frames have lower thermal performance due to the very high thermal conductivity of aluminum. Fenestration systems constructed of aluminum alloys therefore have lower performance in terms of being effective barrier to energy transfer (heat loss or gain). Despite the lower energy performance, aluminum is the choice material for commercial framing systems and dominates the commercial/architectural fenestration market because of the reasons mentioned above. In addition, there is no other cost effective and energy efficient replacement material available to take place of aluminum in the commercial/architectural market. Hence it is imperative to improve the performance of aluminum framing system to improve the energy performance of commercial fenestration system and in turn reduce the energy consumption of commercial building and achieve zero energy building by 2025. The objective of this project was to develop high performance, energy efficient commercial

  4. Assessment of Competence in EVAR Stent Graft Sizing and Selection

    DEFF Research Database (Denmark)

    Strøm, M; Lönn, L.; Bech, B.

    2017-01-01

    = .007, respectively), while there was no significant difference between the two non-expert groups (p = 1). A credible passing standard with appropriate consequences was established using the contrasting groups methods. Conclusion: This study presents a standardised and objective assessment tool...... of competence in vessel analysis and stent graft selection for endovascular aortic repair. This was supported by strong validity evidence with good internal consistency and discriminatory ability. The tool may be used to facilitate training and certification of future endovascular specialists....

  5. Bronchial stents

    Directory of Open Access Journals (Sweden)

    Ibrahim Emad

    2006-01-01

    Full Text Available Bronchial stents are mostly used as a Palliative relief of symptoms often caused by airway obstruction, It is also used for sealing of stump fistulas after pneumonectomy and dehiscence after bronchoplastic operations. Advances in airway prosthetics have provided a variety of silicone stents, expandable metal stents, and pneumatic dilators, enabling the correction of increasingly complex anatomical problems. Several series have been published describing the application and results of these techniques. This manuscript reviews the historical development of stents, types, indication, outcome, and complications. Alternative therapies for tracheobronchial stenting were also reviewed

  6. Endovascular Interventions for Acute Ischemic Stroke: A Review of Recent Trials.

    Science.gov (United States)

    Bishop, Bryan M

    2016-03-01

    To review recent endovascular intervention trials for acute ischemic stroke. Recent, randomized controlled trials of endovascular interventions for acute ischemic stroke were identified. The search terms "endovascular" AND "stroke" were used and filter for "randomized controlled trial" was applied; the period searched was January 1, 2013, to October 31, 2015. Randomized controlled trials of endovascular interventions in acute ischemic stroke published within the past 3 years (2013-2015). A total of 8 trials are reviewed: 3 trials published in 2013 demonstrated neutral results for endovascular interventions, and 5 trials published in 2015 demonstrated positive results for endovascular interventions. Potential reasons for the change in outcomes include better patient selection and improvement indevice technology. Patient selection improvements included selecting patients with salvageable brain tissue with an identifiable thrombus on perfusion imaging. The major improvement in device technology was the introduction of the Solitaire Flow Restoration stent retriever and the Trevo stent retriever, both of which have improved recanalization rates compared with earlier devices. Adjunctive medication considerations include the mode of sedation (general or conscious), intraprocedural anticoagulation with heparin, and intra-arterial tissue plasminogen activator. The use of endovascular devices for treating acute ischemic stroke is likely to increase as more centers become capable of integrating them into their stroke programs. It is important for pharmacists to understand the trials that evaluated endovascular interventions because differences exist with respect to device, adjunctive medication, and patient selection, all of which affect patient outcomes. © The Author(s) 2015.

  7. Aneurysm growth after late conversion of thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Hirofumi Kasahara

    2015-01-01

    Full Text Available A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four sequential computed tomography scans demonstrated that the aneurysm was additionally increasing in size probably due to continuous hematoma production, suggesting a possibility of endoleaks. This case demonstrates the importance of careful radiologic surveillance after endovascular repair, and also after partial open conversion.

  8. Endovascular Access for Challenging Anatomies in Peripheral Vascular Interventions.

    Science.gov (United States)

    Vatakencherry, Geogy; Gandhi, Ripal; Molloy, Christopher

    2016-06-01

    Vascular interventionalists continue to expand the scope and breadth of endovascular procedures that we offer to our patients. However, we often have to overcome various anatomical and technical challenges to deliver an endovascular device. This article should give the modern interventionalist an array of technical tips and tricks to enable them to overcome various challenging anatomical features such as vessel tortuosity, vascular calcifications, and increasing abdominal pannus. We also hope to elucidate alternative accesses such as radial access, pedal access, popliteal access, and direct stent access as well as direct aortic access.

  9. Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Fagedet, Dorothee, E-mail: DFagedet@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de medecine interne, Pole Pluridisciplinaire de Medecine (France); Thony, Frederic, E-mail: FThony@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de radiologie et imagerie medicale, Pole d' Imagerie (France); Timsit, Jean-Francois, E-mail: JFTimsit@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de reanimation, Pole Medecine Aiguee Communautaire (France); Rodiere, Mathieu, E-mail: MRodiere@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de radiologie et imagerie medicale, Pole d' Imagerie (France); Monnin-Bares, Valerie, E-mail: v-monnin@chu-montpellier.fr [CHRU Arnaud de Villeneuve, Imagerie Medicale Thoracique Cardiovasculaire (France); Ferretti, Gilbert R., E-mail: GFerretti@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de radiologie et imagerie medicale, Pole d' Imagerie (France); Vesin, Aurelien; Moro-Sibilot, Denis, E-mail: DMoro.pneumo@chu-grenoble.fr [University Grenoble 1 e Albert Bonniot Institute, Inserm U823 (France)

    2013-02-15

    To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable rate of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.

  10. Endovascular treatment of the carotid stump syndrome.

    Science.gov (United States)

    Nano, Giovanni; Dalainas, Ilias; Casana, Renato; Malacrida, Giovanni; Tealdi, Domenico G

    2006-01-01

    In patients with an occluded internal carotid artery, the carotid stump syndrome is a potential source of microemboli that pass through the ipsilateral external carotid artery and the ophthalmic artery to the territory of the middle cerebral artery. Thus, the syndrome is associated with carotid territory symptoms although the internal carotid artery is occluded. Surgical exclusion of the internal carotid artery associated with endarterectomy of the external carotid artery has been described as the gold standard of treatment by many authors. This report is the second case, to our knowledge, of endovascular treatment of the carotid stump syndrome with the use of a stent-graft.

  11. A noninterventional management approach to endovascular coil migration into the sigmoid colon.

    Science.gov (United States)

    Sexton, Jonathan J; Whittaker, David R

    2015-02-01

    A 75-year-old man underwent endovascular treatment of a right internal iliac artery (IIA) aneurysm by placing coils in the distal IIA and occluding the inflow with a common iliac artery-to-external iliac artery stent graft. Surveillance computed tomography angiography discovered migration of an endovascular coil from the thrombosed right IIA into the sigmoid colon. Subsequent serial imaging demonstrated uncomplicated extracorporeal passage of the coil. We review the relevant literature and treatment rationale. Published by Elsevier Inc.

  12. The frequency of intracranial arterial fenestrations: A study with 64-detector CT-angiography

    Energy Technology Data Exchange (ETDEWEB)

    Bayrak, Aylin Hasanefendioglu, E-mail: aylin_has@yahoo.com [Dicle University, School of Medicine, Radiology Department, Diyarbakir (Turkey); Senturk, Senem, E-mail: ssenturk@dicle.edu.tr [Dicle University, School of Medicine, Radiology Department, Diyarbakir (Turkey); Akay, Hatice Ozturkmen, E-mail: hozturkmen@gmail.com [Veni Vidi Hospital, Diyarbakir (Turkey); Ozmen, Cihan Akgul, E-mail: cihanakgul@dicle.edu.tr [Dicle University, School of Medicine, Radiology Department, Diyarbakir (Turkey); Bukte, Yasar, E-mail: ybukte@dicle.edu.tr [Dicle University, School of Medicine, Radiology Department, Diyarbakir (Turkey); Nazaroglu, Hasan, E-mail: hnazarog@dicle.edu.tr [Dicle University, School of Medicine, Radiology Department, Diyarbakir (Turkey)

    2011-03-15

    Fenestration is a vascular variation that begins with a common origin, then splits into two parallel luminal channels and rejoins distally. Potential association between anomalies of cerebral circulation and increased occurrence of aneurysm makes intracranial arterial fenestrations important. The planning of intracranial arterial interventions may be complicated if a fenestration occurs proximal to the site of intended treatment. This study is planned to determine the frequency of fenestrations on CT angiography and to search whether there is relationship between aneurysms and fenestrations. CT angiographies of 395 consecutive patients, performed by 64-detector CT, were retrospectively reviewed for aneurysms and fenestrations. Overall fenestration frequency, fenestration frequency in patients with and without aneurysm, and aneurysm frequency in patients with and without fenestration were searched. Demographic characteristics of patients were also compared. Overall fenestration frequency was 12.9%. Vertebrobasilar system (5.56%) and anterior communicating region (5.32%) were the two most frequent sites of fenestration. The rate of fenestrations was not significantly different between patients who had and did not have aneurysms. Mean age was significantly higher, and females were predominant in patients with aneurysms. However our results did not show significant difference in age and sex of patients with fenestrations. The frequency of fenestrations in this study is higher than in previously published radiological studies, suggesting that fenestrations are relatively common. There is no significant relationship between the frequency of aneurysms and fenestrations.

  13. Delayed pan-hypopituitarism as a complication following endovascular treatment of bilateral internal carotid artery aneurysms. A case report and review.

    Science.gov (United States)

    Hall, Jonathan; Caputo, Carmela; Chung, Carlos; Holt, Michael; Wang, Yi Yuen

    2015-04-01

    Pan-hypopituitarism has been reported in patients who are subsequently found to have a cerebral aneurysm and there have been reports of pituitary dysfunction immediately following both surgical and endovascular treatment. The authors report a rare case of delayed pan-hypopituitarism following endovascular treatment of bilateral internal carotid artery aneurysms with coil embolisation and flow-diverting stents.

  14. Investigation of the dynamic diameter deformation of vascular stents during fatigue testing with radial loading

    Directory of Open Access Journals (Sweden)

    Boeck Maria

    2015-09-01

    Full Text Available Endovascular stents are exposed to cyclic loads resulting from daily activity and pulsatile arterial blood pressure. DIN EN ISO 25539-2 and FDA guideline 1545 recommend durability testing, exposing stents to physiological cyclic loads for a 10 year equivalent. For accelerated testing, the simulated deformation has to be comparable to physiological in-vivo deformation. A new test setup is presented to determine diameter deformation of vascular stents during fatigue testing with radial loading.

  15. 腔内支架植入术治疗国内Stanford B型主动脉夹层的系统评价%Endovascular stent-graft placement for the treatment of Stanford type B aortic dissection in China:A systematic review

    Institute of Scientific and Technical Information of China (English)

    王俊伟; 李勇辉; 李永欣; 崔进; 李文; 汪洋; 王深明; 王劲松

    2016-01-01

    ObjectiveTo summarize the efficacy, technique feasibility, and clinical safety of endovascular repair for Stanford type Baortic dissection (AD) in China.MethodsWe comprehensively searched the English-language medicalliterature in PubMed, Web of Science, and the Cochrane Library and the Chinese-language medical literatures in CBMdisc (Chinese Biomedical Database), CNKI (China National Knowledge Infrastructure), and Wanfang Data. This systematic review was based on all retrospective studies assessing outcomes of Stanford type BAD treated with endovascular stent-graft placement in China.ResultsA total of 153 retrospective studies that included 8 415 cases of type B AD were analyzed in this study. Procedure success was reported in (99.7±0.1)% of patients. Overall complications were reported in (19.1±0.6)% of patients. Postoperative endoleak occurred in (7.2±0.3)% of patients. Major complications were reported in (3.2±0.2)% of patients, with a neurological complication rate of (1.3±0.1)%. Periprocedural stroke occurred more frequently than paraplegia (0.8%±0.1% versus 0.1%±0.04%). Overall complications was signiifcantly greater in patients treated with ifrst-generation stents compared with second-generation stents (25.1%±1.2% versus 9.5%±0.9%,P<0.001). The in-hospital mortality rate was (1.6±0.1)%. Additionally, (1.8±0.2)% of patients died during a mean follow-up period of (29.4±13.5) months. The Kaplan-Meier estimates of the overall survival rate were (99.0±0.1)% at 30 days, (98.5±0.2)% at 6 months, (98.4±0.2)% at 1 year, (98.1±0.2)% at 2 years, and (97.9±0.2)% at 5 years.ConclusionsEndovascular stent-graft placement is feasible and has a high technique success rate and favorable neurological complication and survival rates in treating Stanford type B AD. Technique improvements in stent-graft design and device delivery catheters have attempted to address previously encountered dififculties. The second-generation of stent-grafts has better in

  16. Endovascular treatment of thoracic aortic aneurysms: a review

    Energy Technology Data Exchange (ETDEWEB)

    Thurnher, Siegfried A. [Department of Radiology, University Hospital, Wien (Austria); Grabenwoeger, Martin [Department of Cardio-Thoracic Surgery, University of Vienna (Austria)

    2002-06-01

    Open surgical repair is considered the traditional treatment for patients with thoracic aortic aneurysms (TAA). In view of the persistent perioperative mobidity and mortality, endovascular stent-graft placement as a minimally invasive and potentially safer treatment for aneurysm of the descending aorta was introduced in 1992. Since then, progress has been made and several institutions have substantiated the safety and effectiveness of stent grafts in the repair of descending TAAs or type-B aortic dissections. Currently, both custom-designed, home-made, and commercially available stent grafts are used. Prior to placement of the endoprosthesis, three major prerequisites must be considered: the localization and morphology of the aneurysm; the distal vascular access of sufficient size; and a limited tortuosity of the abdominal and thoracic aorta. Although short-term results are encouraging, severe complications, including paraplegia, cerebral strokes, and aortic rupture, have been encountered. The long-term durability of currently available stent-graft systems is nonexistent and material fatigue are of major concern to both surgeons and radiologists. Nevertheless, endovascular stent-graft placement could become the procedure of choice in a substantial number of patients with descending TAA. (orig.)

  17. Numerical Simulation of Hemodynamic Effects of Endovascular Stent on the Area of Intracranial Aneurysms%血管支架对颅内动脉瘤血液动力学的数值模拟

    Institute of Scientific and Technical Information of China (English)

    胡成龙; 木合塔尔·克力木; 张光武; 刘鹏; 刘小月; 王丽君

    2016-01-01

    血管支架作为治疗颅内动脉瘤的新方法被广泛运用到临床中,而且越来越普遍。但由于某些支架植入后不能满足力学要求或对瘤内血液动力学无明显影响,反而更易形成血栓,造成动脉瘤破裂。本研究首先通过结构静力学分析比较矩形截面网格状支架和网丝编织成的圆形截面螺旋形支架的弯曲变形能力及扭转变形能力;然后将网格支架植入实际脑动脉瘤模型,进行流-固耦合模拟仿真,分析血流速度、壁面压力及壁面剪切力变化。结果表明:两种支架能够在不损失径向支撑力的情况下,提供良好的轴向顺应性,且网格状支架的变形能力高于螺旋状支架;支架植入后血液动力学各项指标明显降低。血管支架对颅内动脉瘤血液动力学有很大影响,可为临床治疗动脉瘤提供理论依据。%As a new method for treating intracranial aneurysm,intravascular stent has been widely used in clinical practice and be-coming more and more popular.However,some of the implanted intravascular stent cannot meet the requirement of mechanics,or with-out discernible effect on tumour hemodynamic,but result in thrombus or rupture of aneurysms easily.With the application of structural statics,the resistance to bending and torsional deformation between latticed stent with rectangular section and spiralstent wove by mesh with circular cross section was analyzed and compared;then the latticed stent was implanted into cerebral aneurysm,and simulated fli-ud structure interaction to analyse the change of blood flow velocity,wall pressure and wall shear force.Result showed that both stent could provide good axial compliance without damaging radial support force,and the resistance to deformation of latticed stent was better than that of spiral stent;the indicators for hemodynamic were reduced dramatically after implanting the stent.Intravascular stent has great influence on the

  18. Fenestrated internal jugular vein: a rare finding in neck dissection.

    Science.gov (United States)

    Moreno-Sánchez, M; Hernández Vila, C; González-García, R; Monje, F

    2015-09-01

    Fenestration of the internal jugular vein (IJV) is an extremely rare phenomenon. An 85-year-old woman was referred to our department with T2N0M0 squamous cell carcinoma of the right floor of the mouth. The patient underwent local resection, an ipsilateral modified type 3 radical neck dissection, and microsurgical reconstruction. During neck dissection, a fenestration was observed in the middle of the IJV. No structure passed through the fenestration. Such anatomical variations are rare, but clinicians and surgeons should be aware of them in order to avoid damage to the important vascular structures, especially if a neck dissection is performed.

  19. Construct validity and reliability of structured assessment of endovascular expertise in a simulated setting

    DEFF Research Database (Denmark)

    Bech, B.; Lönn, L.; Falkenberg, M.

    2011-01-01

    Objectives To study the construct validity and reliability of a novel endovascular global rating scale, Structured Assessment of endoVascular Expertise (SAVE). Design A Clinical, experimental study. Materials Twenty physicians with endovascular experiences ranging from complete novices to highly...... experienced operators performed a video-recorded simulated contra-lateral iliac-artery-stenting procedure. The virtual-patient case was a novel technically challenging procedure presenting the distal arteries below the knee. Methods Three experts assessed the performances blinded to operator identity...

  20. Salvage of bilateral renal artery occlusion after endovascular aneurysm repair with open splenorenal bypass

    Directory of Open Access Journals (Sweden)

    Samuel Jessula, MDCM

    2017-09-01

    Full Text Available We report renal salvage maneuvers after accidental bilateral renal artery coverage during endovascular aneurysm repair of an infrarenal abdominal aortic aneurysm. A 79-year-old man with an infrarenal abdominal aortic aneurysm was treated with endovascular aneurysm repair. Completion angiography demonstrated coverage of the renal arteries. Several revascularization techniques were attempted, including endograft repositioning and endovascular stenting through the femoral and brachial approach. The patient eventually underwent open splenorenal bypass with a Y Gore-Tex graft (W. L. Gore & Associates, Flagstaff, Ariz. After 3 months, computed tomography showed no evidence of endoleak and patent renal arteries. Renal function was well maintained, and the patient did not require dialysis.

  1. Endovascular treatment strategies for supra-aortic arterial occlusive disease.

    Science.gov (United States)

    Peeters, P; Verbist, J; Deloose, K; Bosiers, M

    2005-06-01

    Because of the focal nature of stenoses or occlusions in the supra-aortic vasculature, the high blood-pressures in this area and the very low morbidity rates related to percutaneous therapy have largely replaced surgical revascularization as the initial treatment of choice for patients with supra-aortic arterial occlusive disease. The initial technical success and durability of percutaneous angioplasty (PTA) and stenting in these lesions is excellent. Nevertheless several factors can make PTA and stenting a complex procedure that requires advanced endovascular skills for a successful outcome. Profound knowledge of surgical reconstruction techniques or extra-anatomic bypasses remains mandatory, as it is occasionally required for failure of endovascular techniques or if contraindications exist.

  2. Endovascular treatment of acute type B dissection complicating aortic coarctation.

    Science.gov (United States)

    Kassaian, Seyed Ebrahim; Abbasi, Kyomars; Mousavi, Mehdi; Sahebjam, Mohammad

    2013-01-01

    Surgical treatment poses a high risk to patients with concomitant aortic coarctation and dissection, and an interventional approach could be an alternative. We describe the case of a 52-year-old man with a long history of untreated hypertension and aortic coarctation who emergently presented at our institution with an acute Stanford type B dissection. The patient's elevated serum creatinine level, perfusion deficit in the right lower limb, and hypertension did not respond to medical therapy, and he did not consent to surgery. By endovascular means, we used a self-expandable stent-graft to cover the entry point of the dissection; then, we deployed a balloon-expandable bare-metal stent to correct residual stenosis. To our knowledge, this is the first report of the endovascular treatment of aortic coarctation complicated by type B dissection.

  3. Midterm experience with the endovascular treatment of isolated iliac aneurysms.

    Science.gov (United States)

    Casana, R; Nano, G; Dalainas, I; Stegher, S; Bianchi, P; Tealdi, D G

    2003-03-01

    The aim of this retrospective, single institution study was to describe our 4-year experience with the endovascular repair of isolated iliac artery aneurysms. Between May 1997 and June 2001, 16 patients (15 males; mean age 64+/-9 years), were treated with covered stent grafts. Twelve of the endovascular procedures were performed under epidural and 4 under local anaesthesia. The percutaneous approach was employed in 13 cases and the femoral artery had to be exposed in 3 cases that demanded simultaneous revascularization of the peripheral circulation (n=2) or required a 16 F sheath to employ a Baxter Lifepath stent graft (n=1). The mean size of the iliac aneurysms was 4.5 cm (range 3.5 to 5.2 cm). Four aneurysms involved the hypogastric ostium in absence of any distal neck. All the patients underwent initially successful endovascular treatment of isolated iliac aneurysms and were followed from 3 to 52 months (mean 18 months). No procedural deaths and no acute or late graft thrombosis occurred. The perioperative complications included 1 dissection of the external iliac artery that required a further endovacular procedure and 1 case of endovascular leak fed to the hypogastric artery. A CT scan 4 months later showed spontaneous thrombosis of aneurysm and no further leakage. Two patients had undergone combinated femoro-popliteal arterial bypass. In our early clinical experience the use of self-expandable covered stent graft successful treated isolated iliac artery aneurysms. Endovascular repair is a safe and effective technique with good midterm results in patients at standard and high risk.

  4. Combined endovascular treatment of aorto-oesophageal fistula with mediastinitis

    Science.gov (United States)

    Berna, Pascal; Pequignot, Aurélien; De Temmerman, Pierre; De Dominicis, Florence

    2013-01-01

    False aortic aneurysm is an uncommon complication after oesophageal perforation and results in a high rate of mortality. A 63-year-old patient presented with acute chest pain. Biochemical tests (cardiac enzymes) and electrocardiogram were normal. A thoracic and abdominal CT scan was performed, and showed a foreign body in the posterior mediastinum, with mediastinal cellulitis and a false aortic aneurysm. Surgical endovascular management was performed, with stenting of the thoracic aorta and oesophageal exploration. PMID:23042800

  5. Endovascular treatment of thoracic aortic diseases: Follow-up and complications with multi-detector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Iezzi, Roberto [Department of Radiology, University ' G. D' Annunzio' , Chieti (Italy)], E-mail: r.iezzi@rad.unich.it; Cotroneo, Antonio Raffaele; Marano, Riccardo; Filippone, Antonella; Storto, Maria Luigia [Department of Radiology, University ' G. D' Annunzio' , Chieti (Italy)

    2008-03-15

    Endovascular procedures with placement of stent-graft has become an accepted alternative to traditional open surgery for treatment of descending thoracic aortic aneurysms, ulcers, post-traumatic rupture, or complications of type-B dissection, due to significant reduction in perioperative mortality, rate of complications and length of hospitalization. Moreover, increasing operator experience and continuous advances in stent-graft technology are making treatment of a wider range of cases possible with redefinition of guidelines for endovascular stent-graft. The feasibility of endovascular stent-graft is mainly dependent on anatomic factors which represent the important predictors of the success of this procedure as well as on strictly follow-up in order to obtain early detection and treatment of eventual complications. Multi-detector CT-angiography is a fast, safe, and minimally invasive imaging technique that represents the standard of reference in the follow-up of patients who have undergone endovascular stent-graft, as it is effective and specific in the detection of procedure-correlated complications. The purpose of this article is to give a brief review of those techniques most commonly used for endovascular treatment of thoracic aortic diseases together with a more detailed description of post-procedural complications and their appearance on multi-detector CT-angiography.

  6. Stent-based mechanical thrombectomy in acute basilar artery occlusion.

    Science.gov (United States)

    Cohen, José E; Leker, Ronen R; Moscovici, Samuel; Attia, Moshe; Itshayek, Eyal

    2011-12-01

    Stent-based mechanical thrombectomy was recently proposed as an effective alternative to other mechanical techniques to achieve recanalization of large-vessel embolic occlusions in the anterior circulation. To our knowledge, there are no reports of the use of this technique in acute basilar artery occlusion (ABAO). We present a patient with complete endovascular recanalization of ABAO using a stent-based thrombectomy technique. Advantages and limitations of this technique in the management of ABAO are discussed. The stent-thrombectomy technique is promising, and will need further evaluation in posterior circulation stroke. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Stent-graft repair of a recurrent popliteal arteriovenous fistula

    NARCIS (Netherlands)

    Tielliu, IFJ; Verhoeven, ELG; Prins, TR; van Det, M; van den Dungen, JJAM

    2002-01-01

    Purpose: To describe the successful endovascular treatment of a popliteal arteriovenous fistula with a stent-graft. Case Report: A 54-year-old man was referred to our hospital with a distal popliteal arteriovenous fistula following an arthroscopic meniscectomy 6 years earlier. Three surgical attempt

  8. Endovascular procedures and new insights in diabetic limb salvage.

    Science.gov (United States)

    Peeters, P; Verbist, J; Keirse, K; Callaert, J; Deloose, K; Bosiers, M

    2012-02-01

    Critical limb ischemia (CLI) is affecting an increasing number of patients, mainly due to an ageing population and the growing number of diabetics. Clinically, CLI is characterized by rest pain, non-healing foot wounds and gangrene, due to insufficient arterial blood supply. Limb preservation should be the goal in patients with diabetic foot due to tibial occlusive disease. As surgery is associated with considerable morbidity and mortality rates, endovascular therapy can offer a valuable alternative. Small-diameter below-the-knee arteries that were previously unamenable to surgical methods, can now be reached and treated. Currently, many endovascular techniques are available, from regular PTA and bare metal stents to drug-coated balloons and drug-eluting stents. In our opinion the results of endovascular therapy for below-the-knee vessels will be further improved by the continuous technical evolution and new material developments. In the light of the current evolution towards minimally invasive techniques, an increasing number of experienced centers will be able to treat the vast majority of all below-the-knee arterial pathology by endovascular means.

  9. Delayed Type IIIb endoleak secondary to graft fabric tear 7 years following implantation of a Medtronic Talent endovascular aortic device: A case report and review of the literature.

    Science.gov (United States)

    Kansal, Vinay; Nagpal, Sudhir

    2016-01-01

    To report a rare case of delayed Type IIIb endoleak secondary to fabric tear following implantation of a Medtronic Talent endovascular device. A 83-year old gentleman underwent elective endovascular aneurysm repair for infrarenal abdominal aortic aneurysm with a Medtronic bifurcated stent graft in 2008. Seven years after the initial repair, imaging surveillance revealed significant endoleak and brisk aneurysm sac expansion due to Type IIIb endoleak secondary to endograft limb fabric tear. This case illustrates the imperative role of imaging surveillance in detection of long-term endovascular aneurysm repair complications. Furthermore, we discuss exclusion of the graft tear with aortouniiliac stent grafting as the treatment for this complication.

  10. Are bio-absorbable stents the future of SFA treatment?

    Science.gov (United States)

    Peeters, P; Keirse, K; Verbist, J; Deloose, K; Bosiers, M

    2010-02-01

    Several limitations inherent to the implantation of a metallic device, such as the occurrence of in-stent re-stenosis, in an arterial lumen intuitively explain the interest for developing bio-absorbable stents. Two main types of bio-absorbable stents currently exist: polymer stents and metallic stents. To date, no studies with bio-absorbable stents have been conducted in the superficial femoral artery (SFA). Because of their strut thickness and lack of radial force, polymer stents are no good candidates for endovascular use. Absorbable metal stents (AMS) do have the potential to perform well for artery treatment, although current evidence from in-human coronary and infrapopliteal studies yield unsatisfactory results. Drastic technological improvements are mandatory before AMS can be considered for every day practice. Yet, it is our belief that further development of other metal and non-metal bio-absorbable stents, with or without drug-coating, may lead to the creation of the ultimate SFA stent.

  11. Stents: Biomechanics, Biomaterials, and Insights from Computational Modeling.

    Science.gov (United States)

    Karanasiou, Georgia S; Papafaklis, Michail I; Conway, Claire; Michalis, Lampros K; Tzafriri, Rami; Edelman, Elazer R; Fotiadis, Dimitrios I

    2017-04-01

    Coronary stents have revolutionized the treatment of coronary artery disease. Improvement in clinical outcomes requires detailed evaluation of the performance of stent biomechanics and the effectiveness as well as safety of biomaterials aiming at optimization of endovascular devices. Stents need to harmonize the hemodynamic environment and promote beneficial vessel healing processes with decreased thrombogenicity. Stent design variables and expansion properties are critical for vessel scaffolding. Drug-elution from stents, can help inhibit in-stent restenosis, but adds further complexity as drug release kinetics and coating formulations can dominate tissue responses. Biodegradable and bioabsorbable stents go one step further providing complete absorption over time governed by corrosion and erosion mechanisms. The advances in computing power and computational methods have enabled the application of numerical simulations and the in silico evaluation of the performance of stent devices made up of complex alloys and bioerodible materials in a range of dimensions and designs and with the capacity to retain and elute bioactive agents. This review presents the current knowledge on stent biomechanics, stent fatigue as well as drug release and mechanisms governing biodegradability focusing on the insights from computational modeling approaches.

  12. The role of superficial femoral artery endoluminal bypass in long de novo lesions and in-stent restenosis.

    NARCIS (Netherlands)

    Doomernik, D.E.; Golchehr, B.; Lensvelt, M.M.A.; Reijnen, M.M.P.J.

    2012-01-01

    AIM: Results of endovascular treatment for long de novo lesions of the superficial femoral artery (SFA) are limited by in-stent restenosis (ISR). Polytetrafluoroethylene (PTFE) covered stents are developed to reduce the incidence of ISR. This study was conducted to summarize available data on the us

  13. Efficacy of Stent-Retriever Thrombectomy in Magnetic Resonance Imaging Versus Computed Tomographic Perfusion-Selected Patients in SWIFT PRIME Trial (Solitaire FR With the Intention for Thrombectomy as Primary Endovascular Treatment for Acute Ischemic Stroke).

    Science.gov (United States)

    Menjot de Champfleur, Nicolas; Saver, Jeffrey L; Goyal, Mayank; Jahan, Reza; Diener, Hans-Christoph; Bonafe, Alain; Levy, Elad I; Pereira, Vitor M; Cognard, Christophe; Yavagal, Dileep R; Albers, Gregory W

    2017-06-01

    The majority of patients enrolled in SWIFT PRIME trial (Solitaire FR With the Intention for Thrombectomy as Primary Endovascular Treatment for Acute Ischemic Stroke) had computed tomographic perfusion (CTP) imaging before randomization; 34 patients were randomized after magnetic resonance imaging (MRI). Patients with middle cerebral artery and distal carotid occlusions were randomized to treatment with tPA (tissue-type plasminogen activator) alone or tPA+stentriever thrombectomy. The primary outcome was the distribution of the modified Rankin Scale score at 90 days. Patients with the target mismatch profile for enrollment were identified on MRI and CTP. MRI selection was performed in 34 patients; CTP in 139 patients. Baseline National Institutes of Health Stroke Scale score was 17 in both groups. Target mismatch profile was present in 95% (MRI) versus 83% (CTP). A higher percentage of the MRI group was transferred from an outside hospital (P=0.02), and therefore, the time from stroke onset to randomization was longer in the MRI group (P=0.003). Time from emergency room arrival to randomization did not differ in CTP versus MRI-selected patients. Baseline ischemic core volumes were similar in both groups. Reperfusion rates (>90%/TICI [Thrombolysis in Cerebral Infarction] score 3) did not differ in the stentriever-treated patients in the MRI versus CTP groups. The primary efficacy analysis (90-day mRS score) demonstrated a statistically significant benefit in both subgroups (MRI, P=0.02; CTP, P=0.01). Infarct growth was reduced in the stentriever-treated group in both MRI and CTP groups. Time to randomization was significantly longer in MRI-selected patients; however, site arrival to randomization times were not prolonged, and the benefits of endovascular therapy were similar. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01657461. © 2017 American Heart Association, Inc.

  14. Subarachnoid hemorrhage with blister aneurysms: Endovascular management

    Directory of Open Access Journals (Sweden)

    Swati Dayanand Chinchure

    2014-01-01

    Full Text Available Blister aneurysms of are rare lesions representing a real challenge for diagnosis and management. They typically show small size, hemispherical shape, fragile wall, broad neck, and are arising from non-branching sites of intracranial arteries. Materials and Methods: We retrospectively reviewed all aneurysms treated at our institution. Seventeen patients (6 male, 11 female with 17 blister aneurysms were identified (mean age 53.3, range 41-63 years. Clinical, procedural, angiographic data as well as follow up data were evaluated. Results: All patients presented with aneurysmal subarachnoid hemorrhage. Majority of the blister aneurysms were located in ICA while 1 was located at posterior cerebral artery, 1 at vertebral and 1 involving basilar artery. All patients were treated using single or overlapping stents and if possible additional coiling. There was no intra-operative rupture. Good outcome (mrs 0-2 was seen in 14 patients. Poor clinical outcome (mrs 3-5 was seen in 2 patients due to vasospasm induced ischemic deficits at discharge, both of them improved on follow up (mrs 1 on follow up. There were 3 mortalities, One patient died of rebleeding while other 2 died due to SAH induced complications. Follow-up angiography was available in 16 patients (one patient died before follow up angiogram and revealed complete or near complete aneurysm occlusion in 11, incomplete obliteration in 1 and no change in 2 cases. Two cases showed post-treatment angiographic aneurysm recurrence. Both cases were managed with repeat coiling and overlapping stent placement. Conclusion: Endovascular management using single/overlapping stent and if possible coil placement is technically safe and feasible in blister aneurysms. Overlapping stents lead to better aneurysm occlusion than a single stent. Blister aneurysm in dorso-medial ICA showed higher tendency of continued growth/recurrence, higher incidence of clinical vasospasm and in these cases early angiographic follow

  15. Use of a remotely steerable "robotic" catheter in a branched endovascular aortic graft.

    Science.gov (United States)

    Carrell, Tom; Dastur, Neville; Salter, Richard; Taylor, Peter

    2012-01-01

    We report the use of a remotely steerable catheter to treat kinked renal bridging stents 8 months after branched endovascular repair of a type III thoracoabdominal aortic aneurysm. Conventional techniques using single, coaxial, and manually steerable sheaths proved too unstable to provide the support required to pass a wire against resistance through the kinked stent. A remotely steerable "robotic" catheter provided sufficient precision and stability to cross the kink and reline it with an additional stent, restoring renal perfusion. This technology can help achieve precise and stable introducer sheath position. Further evaluation is necessary to understand the wider applications.

  16. Suprarenal Fixation Resulting in Intestinal Ischemia after Endovascular Aortic Aneurysm Repair

    NARCIS (Netherlands)

    Pol, Robert A.; Keus, Frederick; Prins, Ted R.; Zeebregts, Clark J.

    2014-01-01

    Endovascular aneurysm repair (EVAR) may be associated with specific stent- and procedure-related complications. Hepatic artery anatomic variability may lead to dramatic consequences when unanticipated. A 64-year-old man presented with a 6-cm abdominal aortic aneurysm, suitable for an EVAR procedure.

  17. Endovascular reconstruction of aneurysms with a complex geometry

    Directory of Open Access Journals (Sweden)

    Vipul Gupta

    2016-01-01

    Full Text Available Conventional endovascular coiling remains the mainstay of treatment for most aneurysms; however, it may not be suitable for aneurysms with a complex geometry and there remains the risk of recanalization. Aneurysms with an unfavorable morphology are difficult to treat through both endovascular and surgical means. Progress in endovascular technology has allowed for the emergence of newer strategies to treat aneurysms with a complex geometry. Better packing density in wide-necked and large aneurysms can be achieved through the balloon remodeling technique. Similarly, a self-expanding stent cannot only act as a scaffold that helps to retain coils but also aids in diverting the blood flow away from the aneurysm sac. Lately, focus has shifted from endosaccular occlusion to endoluminal reconstruction; flow diverters are being increasingly used to treat aneurysms with an unfavorable geometry. However, there is no clear consensus on the best endovascular management strategy in certain subset of aneurysms - large and giant internal carotid aneurysms, blister aneurysms, and fusiform/dissecting aneurysms of the vertebrobasilar artery. We present a review of literature and discuss the current evidence for the various endovascular strategies to treat complex aneurysms.

  18. Vascular interventional radiology. Current evidence in endovascular surgery. 2. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Cowling, Mark G. (ed.) [Univ. Hospital North Staffordshire, Stoke-on-Trent (United Kingdom). Dept. of Radiology

    2012-11-01

    Succinct chapters that will allow readers to identify quickly the information that they need. Ideally sized book for storage and use in the interventional suite. Contains sufficient detail for trainees in endovascular therapy/interventional radiology to gain a thorough grasp of the relevant issues. Fully updated to reflect recent advances. This new edition of Vascular Interventional Radiology: Current Evidence in Endovascular Surgery provides a thorough yet succinct and accessible review of the latest knowledge in the field of endovascular surgery. All chapters have been updated to reflect the advances that have occurred during the past five years, and new chapters are included on carotid artery stenting and day case intervention. The chapter on lower limb veno-occlusive disease has been expanded to include management of deep venous thrombosis. Among the other topics considered are the endovascular treatment options in different arterial territories, aneurysm repair techniques, and the management of venous stenosis and venous insufficiency. The aim throughout is to tackle issues of evidence-based practice in order to assist trainees and experienced practitioners in making and implementing treatment decisions. This book will be an invaluable source of information for both interventional radiologists and vascular surgeons with an interest in endovascular techniques.

  19. Endovascular Treatment of Posttraumatic Pseudoaneurysm of the Common Carotid Artery

    Directory of Open Access Journals (Sweden)

    Diego Rojas

    2015-01-01

    Full Text Available Carotid artery injuries with pseudoaneurysm are uncommon but associated with central neurologic dysfunction. We present a case of posttraumatic pseudoaneurysm of the right common carotid artery treated by implantation of a covered stent. A 44-year-old woman with multiple injuries after fall from height presents a small dissection flap of the right common carotid artery (RCCA on the initial computed tomography angiography (CTA. Fifteen days later a 10 mm pseudoaneurysm is observed on control CTA. We decided endovascular treatment. Through right femoral access with a long introducer sheath placed in the innominate artery, we implanted a covered stent Advanta V12 9×38 mm in the RCCA. The patient was discharged from the hospital with antiplatelet therapy without any neurological dysfunction and complete exclusion of the pseudoaneurysm. Use of covered stents has emerged as a safe and effective alternative to surgical repair of carotid injuries.

  20. Endovascular management of intracranial blister aneurysms: spectrum and limitations of contemporary techniques.

    Science.gov (United States)

    Ashour, Ramsey; Dodson, Stephen; Aziz-Sultan, M Ali

    2016-01-01

    Intracranial blister aneurysms are rare lesions that are notoriously more difficult to treat than typical saccular aneurysms. High complication rates associated with surgery have sparked considerable interest in endovascular techniques, though not well-studied, to treat blister aneurysms. To evaluate our experience using various endovascular approaches to treat blister aneurysms. All consecutive blister aneurysms treated using an endovascular approach by the study authors over a 3-year period were retrospectively analyzed. A literature review was also performed. Nine patients with blister aneurysms underwent 11 endovascular interventions. In various combinations, stents were used in 8/11, coils in 5/11, and Onyx in 3/11 procedures. At mean angiographic follow-up of 200 days, 8/9 aneurysms were completely occluded by endovascular means alone requiring no further treatment and 1/9 aneurysms required surgical bypass/trapping after one failed surgical and two failed endovascular treatments. At mean clinical follow-up of 416 days, modified Rankin Scale scores were improved in six patients, stable in two, and worsened in one patient. One complication occurred in 11 procedures (9%), resulting in a permanent neurologic deficit. No unintended endovascular parent vessel sacrifice, intraprocedural aneurysmal ruptures, antiplatelet-related complications, post-treatment aneurysmal re-ruptures, or deaths occurred. This series highlights both the spectrum and limitations of endovascular techniques currently used to treat blister aneurysms, including a novel application of stent-assisted Onyx embolization. Long-term follow-up and experience in larger studies are required to better define the role of endovascular therapy in the management of these difficult lesions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. David M. Hume Memorial Lecture. Impact of endovascular technology on the practice of vascular surgery.

    Science.gov (United States)

    Veith, F J; Marin, M L

    1996-08-01

    Endovascular treatment techniques have already replaced some vascular operations. The likelihood is that new endovascular techniques involving stents and stented grafts will replace additional vascular operations. All these treatments involve the use of catheter-guidewire, balloon, and imaging modalities, particularly digital fluoroscopy. These modalities have already and will increasingly help to improve and simplify standard vascular operations such as thromboembolectomy, infrainguinal bypasses, and management of aneurysms and arteriovenous fistulas. Accordingly, vascular surgeons must become familiar with and use these endovascular methods and techniques. This can be accomplished in a variety of ways which includes working as part of a multidisciplinary vascular treatment group in which various specialists collaborate to provide the best, most cost-effective care to vascular disease patients.

  2. Endovascular treatment of coarctation and related aneurysms.

    Science.gov (United States)

    Galiñanes, E L; Krajcer, Z

    2014-06-11

    Today,surgical repair has almost doubled the 30year survival rate in patients with coarctation of the aorta (CoA), and 72% to 98% of patients now reach adulthood. Possible late complications include malignant hypertension, left ventricular dysfunction, aortic valve dysfunction, recurrent CoA, and aneurysm formation with risk of rupture. Treating postoperative CoA-related aneurysms with observation alone is associated with a mortality rate of 36%, compared with 9% for surgical repair. Even in the best surgeons' hands, aortic surgery has associated complications, and the complexity of reoperative surgery makes the risks substantially greater. For patients with CoA-related aneurysm, endovascular treatment constitutes a good alternative to reoperative surgery because it poses a lower risk of morbidity and mortality. Implanting an endograft has been shown to be successful in treating CoA and related aneurysms, producing excellent intermediate outcomes and minimal morbidity and mortality. Despite evidence that using covered stents improves outcomes, the superiority of any particular stent type has yet to be established. With a variety of endografts available, the decision of which stent to use depends on anatomy, availability, and operator preference.

  3. New stent developments for peripheral arterial occlusive disease; Neue Stententwicklungen fuer die periphere arterielle Verschlusskrankheit

    Energy Technology Data Exchange (ETDEWEB)

    Tepe, G. [Romed Kliniken, Klinikum Rosenheim, Institut fuer Diagnostische und Interventionelle Radiologie, Rosenheim (Germany)

    2010-01-15

    Infrainguinal peripheral occlusive disease is increasingly being treated by endovascular techniques. Bare metal stainless steel, self-expanding nitinol stents, drug-eluting and covered stents (stent grafts) are becoming increasingly more important adjuncts to percutaneous translumninal angioplasty in the treatment of peripheral artery disease. In this article the available evidence supporting the use of stents in the femoropopliteal and tibial arteries will be described as well as their limitations. Future stent developments will also be discussed. (orig.) [German] Die endovaskulaere Therapie spielt bei der Therapie der peripheren arteriellen Verschlusskrankheit (PAVK) eine wichtige Rolle. Unbeschichtete ballonexpandierbare Stahlstents, selbstexpandierende Nitinolstents sowie medikamentenbeschichtete und ''covered stents'' (Stentgrafts) haben eine zunehmende Bedeutung als Zusatztherapie zusammen mit der primaeren Ballonangioplastie gewonnen. In diesem Artikel wird die klinische Evidenz beschrieben, die die Anwendung von Stents im Bereich der femoropoplitealen und tibialen Strombahn unterstuetzt. Limitationen sowie zukuenftige Stententwicklungen werden ebenfalls diskutiert. (orig.)

  4. Balloon Angioplasty and Drug Eluting Stenting for Treatment of Peripheral Arterial Occlusive Disease

    Directory of Open Access Journals (Sweden)

    Akın İzgi

    2010-08-01

    Full Text Available Peripheral arterial disease is one of the manifestations of systemic atherosclerosis. In the last decade, remarkable technological advances, especially in the stent area, have shifted revascularization strategies from traditional open surgical approaches toward less morbide percutaneous endovascular treatments. However, even with new designed nitinol bare stents, restenosis remains as the major obstacle of this procedures. More recently, drug eluting stent platforms have been used to treat atherosclerotic peripheral arterial disease. In this article, we reviewed new studies relevant to drug eluting stents for lower extremity peripheral arterial occlusive disease.

  5. 涂覆承载质粒DNA水凝胶的覆膜血管内支架置入主动脉局部基因转染的实验研究%Gene delivery of plasmid DNA to rabbit aorta by genetic engineering of cationized gelatin hydrogel coated partially covered endovascular stent graft

    Institute of Scientific and Technical Information of China (English)

    钟红珊; 徐克; 刘屹; 松井 修

    2008-01-01

    Objective To genetically engineer endovascular stent grafts that facilitate plasmid DNA delivery and offer the promise ofcular delivery system of therapeutic materials. Methods Partially covered polyester stent-grafts coated with cationized gelatin hydrogels (CGH) containing pCAGGS-LacZ or pEGFP were implanted in the descending aorta of 8 rabbits, which had neointima due to balloon injury four weeks ago. The aorta with stent-graft containing pCAGGS-LacZ and the one containing pEGFP was taken as negative control for each other. Expression of the plasmid-encoded marker genes, (3-galactosidase and enhanced green fluorescence protein (EGFP) were evaluated at 3 days after implantations by X-Gal staining and RT-PCR or fluorescence microscopy. Results Local plasmid DNA transfer was confined to the vessel wall at the site of stent-graft implantation, especially where the graft was compressed firmly to the vessel by metal struts. Plasmid DNA was not detected in vessel segments immediately proximal or distal to the stent graft and dissemination of plasmid DNA to brain, heart, lung, liver or kidney was not observed. The (3-galactosidase-expressed cells were identified as endothelial cells, and smooth muscle cells by pathological analysis. Fluorescence microscopy identified the EGFP expression which demonstrated the transgene delivery of plasmid DNA and it was not related to the plasmid-encoded marker genes. No signal was detected in the aorta of the rabbits that received cationized gelatin hydrogels coated stent-grafts without plasmid DNA. Conclusions Cationized gelatin hydrogels coated partially covered stent grafts provide a new access for transgene delivery to the cells of aortic wall.%目的 用部分覆膜血管内支架涂覆阳离子胶原水凝胶(CGH)承载质粒DNA实现主动脉局部的基因转染,为核酸等大分子治疗物质经血管导入提供理论依据.方法 将CGH涂覆于部分覆膜血管内支架的覆膜织物上,以CGH涂层分别承载2种质

  6. Stenting of the SFA - indications, techniques,; Stents in der A. femoralis superficialis - Indikationen, Technik, Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Rieger, J.; Treitl, M.; Reiser, M. [Klinikum Innenstadt der Ludwigs-Maximilians-Universitaet,, Muenchen (Germany). Institut fuer Klinische Radiologie; Ruppert, V. [Chirurgische Klinik und Poliklinik Innenstadt - Klinikum der Ludwigs-Maximilians-Universitaet Muenchen (Germany). Funktionsbereich Gefaesschirurgie

    2006-11-15

    Aggressive risk factor modification, change of eating habits, exercise programs, and forceful antiplatelet therapy are the most important tools for the treatment of PAOD in symptomatic patients suffering from intermittent claudication. There are however no guidelines for revascularization at this stage. Endovascular treatment has been increasingly utilized over the last decade and increasingly displaced vascular surgery. Amongst numerous endovascular techniques beside PTA, stents meanwhile play the most important role due to constant technical progress. Results regarding the rate of restenosis or patency rates still remain worse compared to other vascular beds. This paper gives a review over recent results, currently available stent techniques, and possible indications for the endovascular therapy of an artery, which has turned out to be the biggest ordeal for material and construction of stents. (orig.) [German] Aggressives Risikofaktorenmanagement, Aenderungen der Lebens- und Essgewohnheiten sowie eine konsequente antithrombotische Therapie sind die wichtigsten Saeulen bei der Sekundaerprophylaxe einer symptomatischen peripheren arteriellen Verschlusskrankheit (PAVK) im Stadium der Claudicatio. Bei den revaskularisierenden Verfahren existieren in diesem Stadium keine verbindlichen Richtlinien zur Indikationsstellung. Endovaskulaere Techniken draengen jedoch den klassischen Bypass mehr und mehr zurueck. Unter den zahlreichen endovaskulaeren Therapiemoeglichkeiten haben sich in der A. femoralis superficialis (AFS) neben der perkutanen transfemoralen Angioplastie (PTA) v. a. technisch immer weiter verbesserte Stents etabliert. Die Ergebnisse bzgl. der Inzidenz von Restenosen bzw. der Offenheitsraten fallen aber weiterhin im Vergleich zu anderen arteriellen Stromgebieten schlechter aus. Dieser Artikel gibt einen Ueberblick ueber die z. Z. einsetzbaren Stentmodelle, moegliche Indikationen und die juengsten Ergebnisse der endovaskulaeren Behandlung eines Gefaesses, das

  7. Single-center experience on endovascular reconstruction of traumatic internal carotid artery dissections.

    Science.gov (United States)

    Cohen, José E; Gomori, John M; Itshayek, Eyal; Spektor, Sergey; Shoshan, Yigal; Rosenthal, Guy; Moscovici, Samuel

    2012-01-01

    Traumatic internal carotid artery dissection (CAD) has a potentially grave outcome. Anticoagulant therapy may be ineffective or contraindicated; surgery impractical. We present our experience with endovascular stenting in CAD patients. From 2004 to 2011, 23 patients with angiographically proven traumatic CAD underwent endovascular stent-assisted arterial reconstruction based on clinical and radiographic criteria: contraindication or failure of anticoagulation, evidence of impending ischemic stroke, or need for urgent intracranial revascularization. Dissections were graded based on degree of stenosis and extent of injury. Seventeen patients (73.9%) presented with stroke or transient ischemic attack. Carotid revascularization was achieved with one (11 patients, 48%) or multiple stents (12 patients, 52%); distal protection was used rarely (three patients, 13%). No complications were directly attributed to stenting. Mean dissection-related stenosis improved from 72% ± 28.87% to 4% ± 8.29%. At a mean clinical follow-up of 28.7 months ± 31.9 months, 16 patients (69.6%) improved, six (26.1%) remained stable, and one (4.3%) had died secondary to multiple traumatic injuries. At long-term follow-up, no patient had a transient ischemic attack or stroke or presented evidence of de novo in-stent stenosis or stent thrombosis. There were no neurologic sequelae after partial or total discontinuation of antiplatelet therapy in seven patients undergoing trauma-related surgeries. Selected cases of traumatic CAD can be safely managed by endovascular stent-assisted angioplasty. Procedural complications are infrequent; the need for postprocedure antiplatelet therapy is a concern. Early detection is essential to avoid stroke. Stenting restores the integrity of the vessel lumen immediately, efficiently prevents the occurrence or recurrence of ischemic events, and avoids the need of long-term anticoagulation.

  8. Endovascular Management of Superior Mesenteric Artery (SMA) Aneurysm - Adequate Access is Essential for Success - Case Report.

    Science.gov (United States)

    Tkalčić, Lovro; Budiselić, Berislav; Kovačević, Miljenko; Knežević, Siniša; Kovačić, Slavica; Miletić, Damir; Tomulić, Vjekoslav; Kuhelj, Dimitrij

    2017-01-01

    An aneurysm of the superior mesenteric artery (SMA) with a diameter of 2.2 cm was found incidentally on an ultrasound (US) examination in a 26-year-old woman. The only known risk factor was an intracranial aneurysm that was found on her grandmother's autopsy. Based on pregnancy planning and the current literature, endovascular management with a covered stent was proposed. Self-expandable, covered stent (Bard, Fluency(®)) was implanted using a single transfemoral approach. A stiff guidewire and a large sheath distorted the anatomy, which resulted in an incomplete aneurysmal neck covering. In the absence of additional covered stents, the procedure was terminated. Two weeks later, computed tomographic angiography (CTA) confirmed persistent aneurysmal perfusion due to the incomplete neck coverage. A multidisciplinary board opted for a second endovascular attempt, this time with a longer covered stent via the transaxillary approach in order to reduce anatomical distortion. Balloon, expandable, cobalt-chrome covered stent (Jotec, E-ventus BX(®)) was implanted in the SMA, covering the aneurysmal neck and overlapping the previously implanted covered stent. Angiography confirmed a complete exclusion of the aneurysm. A control US performed three weeks later confirmed a patent covered stent and complete aneurysmal exclusion. There was a mild median nerve damage periprocedurally that resolved in three months. The most recent US control examination, performed eleven months after the procedure, showed an excluded aneurysm and a patent covered stent. There were no clinical signs of bowel ischaemia during the follow-up period. Endovascular management of SMAA proved to be safe and efficient. The "access from above" is probably safer and should be considered in the majority of cases with acceptable sizes of access vessels. Mid-term results in our patient are good and life-long follow-up is planned to prevent late complications.

  9. Endovascular treatment of distal thoracic aortic transection associated with severe thoracolumbar spinal fracture.

    Science.gov (United States)

    Chock, Megan M; Aho, Johnathon; Naik, Nimesh; Clarke, Michelle; Heller, Stephanie; Oderich, Gustavo S

    2015-10-01

    Endovascular repair has become the first line of treatment in most patients with blunt aortic injury. The most common mechanism is deceleration injury affecting the aortic isthmus distal to the origin of the left subclavian artery. Injuries of the distal thoracic aorta are uncommon. We report the case of a 25-year-old male patient who presented with paraplegia and distal thoracic aortic pseudoaneurysm associated with severe thoracolumbar vertebral fracture and displacement after a motocross accident. Endovascular repair was performed using total percutaneous technique and conformable C-TAG thoracic stent-graft (WL Gore, Flagstaff, AZ). Following stent-graft placement and angiographic confirmation of absence of endoleak, thoracolumbar spinal fixation was performed in the same operative procedure. This case illustrates a multispecialty approach to complex aortic and vertebral injury and the high conformability of newer thoracic stent-grafts to adapt to tortuous anatomy. © The Author(s) 2014.

  10. ERCP for the treatment of bile leak after partial hepatectomy and fenestration for symptomatic polycystic liver disease

    Institute of Scientific and Technical Information of China (English)

    Nayantara Coelho-Prabhu; David M Nagorney; Todd H Baron

    2012-01-01

    AIM:TO describe endoscopic treatment of bile leaks in these patients and to identify risk factors in these patients which can predict the development of bile leaks.METHODS:Retrospective case-control study examining consecutive patients who underwent partial hepatectomy for polycystic liver disease (PLD) and developed a postoperative bile leak managed endoscopically over a ten year period.Each case was matched with two controls with PLD who did not develop a postoperative bile leak.RESULTS:Ten cases underwent partial hepatectomy with fenestration for symptoms including abdominal distention,pain and nausea.Endoscopic retrograde cholangiopancreatography (ERCP) showed anatomic abnormalities in 1 case.A biliary sphincterotomy was performed in 4 cases.A plastic biliary stent was placed with the proximal end at the site of the leak in 9 cases;in 1 case two stents were placed.The overall success rate of ERCP to manage the leak was 90%.There were no significant differences in age,gender,comorbidities,duration of symptoms,history of previous surgery or type of surgery performed between cases and controls.CONCLUSION:ERCP with stent placement is safe and effective for management of post-hepatectomy bile leak in patients with PLD.

  11. Percutaneous Endovascular Treatment for Hepatic Artery Stenosis after Liver Transplantation: The Role of Percutaneous Endovascular Treatment

    Science.gov (United States)

    Vidjak, Vinko; Novačić, Karlo; Matijević, Filip; Kavur, Lovro; Slavica, Marko; Mrzljak, Anna; Filipec-Kanižaj, Tajana; Leder, Nikola Ivan; Škegro, Dinko

    2015-01-01

    Summary Background To retrospectively analyze the outcomes of interventional radiology treatment of patients with hepatic artery stenosis (HAS) after liver transplantation at our Institution. Material/Methods Hepatic artery stenosis was diagnosed and treated by endovascular technique in 8 (2.8%) patients, who underwent liver transplantation between July 2007 and July 2011. Patients entered the follow-up period, during which we analyzed hepatic artery patency with Doppler ultrasound at 1, 3, 6, and 12 months after percutaneous endovascular treatment (PTA), and every six months thereafter. Results During the 12-month follow-up period, 6 out of 8 patients (75%) were asymptomatic with patent hepatic artery, which was confirmed by multislice computed tomography (MSCT) angiography, or color Doppler (CD) ultrasound. One patient had a fatal outcome of unknown cause, and one patient underwent orthotopic liver retransplantation (re-OLT) procedure due to graft failure. Conclusions Our results suggest that HAS angioplasty and stenting are minimally invasive and safe endovascular procedures that represent a good alternative to open surgery, with good 12-month follow-up patency results comparable to surgery. PMID:26150902

  12. Endovascular aortic graft infection resulting in retroperitoneal abscess: report of a case

    Directory of Open Access Journals (Sweden)

    Salvatore Di Somma

    2010-06-01

    Full Text Available Infection is a rare complication of aortoiliac endovascular procedures, with an incidence inferior to 0.5%, and it may result in a retroperitoneal abscess potentially evolving to sepsis and gastrointestinal bleeding. In more than 50% of cases endovascular aortoiliac prosthetic grafts infection occur months or years after the procedure. The growing number of endovascular procedures, and as the actually midterm follow up in most cases, septic sequelae will no doubt continue to occur with increased frequency and may represent an emerging problem in the ED for the emergency physician. Endovascular graft infection begins with unspecific clinical manifestations. An high index of suspicion in any patient with an aortic stent graft presenting prolonged or recurrent fever and or abdominal or back pain and a low threshold for obtaining CT scan should increase the clinician’s ability to make a timely diagnosis in the ED setting.

  13. Vascular angular remodeling by kissing-Y stenting in wide necked intracranial bifurcation aneurysms.

    Science.gov (United States)

    Melber, Katharina; Meila, Dan; Draheim, Philipp; Grieb, Dominik; Greling, Björn; Schlunz-Hendann, Martin; Brassel, Friedhelm

    2016-12-05

    Single stent deployment leads to a change in vascular geometry in wide necked bifurcation aneurysms. In some complex cases, the use of the single stent technique might not be sufficient or may not be feasible. The kissing-Y stenting technique appears to be an alternative endovascular treatment option. The aim of this study was to evaluate the effects of the kissing-Y stenting technique on vascular angular remodeling. 21 patients with wide necked intracranial bifurcation aneurysms at different sites (10 anterior communicating artery, 6 middle cerebral artery, 3 basilar artery, 1 vertebral artery/posterior inferior cerebellar artery, 1 internal carotid artery/posterior communicating artery) were treated with 44 closed cell stents (follow-up 2012-2016) using the kissing-Y stenting technique. We analyzed vascular angle geometry between the mother and both affected daughter vessels by digital subtraction angiography, before and after stent deployment, using standard working projections. Endovascular treatment of wide necked intracranial aneurysms using the kissing-Y stenting technique significantly decreased the angle between the bifurcation branches from 130.4±9.5° to 91.5±9.1° (pKissing-Y stenting in wide necked bifurcation aneurysms leads to vascular angular remodeling of both affected branches. The resulting straightening of the bifurcation angle may prevent aneurysmal recurrence. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  14. Endovascular solutions for the management of penetrating trauma: an update on REBOA and axillo-subclavian injuries.

    Science.gov (United States)

    Branco, B C; DuBose, J J

    2016-12-01

    Endovascular procedures continue to gain acceptance as management options for penetrating traumatic injuries. Currently, several areas of potential endovascular application are being investigated. However, the bulk of the literature on this topic is still limited to case series or small retrospective studies. Therefore, we performed a review of the published experience involving the application of endovascular therapy to trauma patients who have sustained penetrating injuries with focus on outcomes of resuscitative endovascular balloon occlusion of the aorta (REBOA) and endovascular repair of axillo-subclavian injuries. Published case reports, retrospective and prospective studies of REBOA and axillo-subclavian injuries were systematically reviewed. A total of 7 studies on REBOA and 10 studies on endovascular repair of axillo-subclavian injuries were included. Overall, REBOA was used as an adjunct for hemorrhage control and resuscitation in patients at risk of cardiopulmonary arrest, preventing further cardiovascular collapse successfully. For axillo-subclavian injuries, endovascular stent placement had efficacy comparable to the traditional open repair. REBOA is a safe and effective alternative to open thoracotomy in critically ill trauma patients at risk of death due to torso hemorrhage. Endovascular repair outcomes are comparable to open repair after axillo-subclavian injuries. Long-term results of endovascular repair remain to be defined in this patient population.

  15. Platypnea-orthodeoxia induced by fenestrated atrial septal aneurysm.

    Science.gov (United States)

    Giombolini, Claudio; Notaristefano, Salvatore; Santucci, Stefano; Savino, Ketty; Pasquino, Stefano; Ragni, Temistocle; Ambrosio, Giuseppe

    2005-02-01

    Platypnea-orthodeoxia is a peculiar syndrome characterized by a right-to-left shunt, which occurs in the upright position. The diagnosis is made by contrast transesophageal echocardiography, paying attention to include contrast visualization in the orthostatic decubitus. The association of this syndrome with a fenestrated atrial septal aneurysm is rare and probably underlies a peculiar and also rare mechanism of shunting in presence of normal pulmonary pressure. We report of a case of a 58-year-old man with a fenestrated atrial septal aneurysm and platypnea-orthodeoxia syndrome treated by surgical closure of the atrial defect.

  16. Gastrointestinal stenting

    Energy Technology Data Exchange (ETDEWEB)

    Zollikofer, C.L.; Schoch, E. [Dept. of Radiology, Kantonsspital Winterthur (Switzerland); Jost, R. [Dept. of Gastroenterology Internal Medicine, Kantonsspital Winterthur (Switzerland); Decurtins, M. [Dept. of Surgery, Kantonsspital Winterthur (Switzerland)

    2000-02-01

    Acute obstructions of the gastric outlet, the duodenum, or the large bowel require rapid treatment to relieve symptoms of retention or ileus. Large-caliber stents of 16 to 22 mm offer a new non-surgical alternative for treating these patients with minimal risks and high success rates. For gastroduodenal outlet obstructions palliated by self-expanded metal stents, clinical success rates are in the range of 80-100 %. Preoperative treatment of colorectal obstructions successfully relieves acute symptoms of ileus in 87-100 % allowing primary anastomosis and thereby reducing the costs caused by multiple operations and the need of intensive care by approximately 25 %. It is the purpose of this review to familiarize the reader with the indications, possibilities, and limits of intestinal stenting. (orig.)

  17. Fabrication and In Vitro Deployment of a Laser-Activated Shape Memory Polymer Vascular Stent

    Energy Technology Data Exchange (ETDEWEB)

    Baer, G M; Small IV, W; Wilson, T S; Benett, W J; Matthews, D L; Hartman, J; Maitland, D J

    2007-04-25

    Vascular stents are small tubular scaffolds used in the treatment of arterial stenosis (narrowing of the vessel). Most vascular stents are metallic and are deployed either by balloon expansion or by self-expansion. A shape memory polymer (SMP) stent may enhance flexibility, compliance, and drug elution compared to its current metallic counterparts. The purpose of this study was to describe the fabrication of a laser-activated SMP stent and demonstrate photothermal expansion of the stent in an in vitro artery model. A novel SMP stent was fabricated from thermoplastic polyurethane. A solid SMP tube formed by dip coating a stainless steel pin was laser-etched to create the mesh pattern of the finished stent. The stent was crimped over a fiber-optic cylindrical light diffuser coupled to an infrared diode laser. Photothermal actuation of the stent was performed in a water-filled mock artery. At a physiological flow rate, the stent did not fully expand at the maximum laser power (8.6 W) due to convective cooling. However, under zero flow, simulating the technique of endovascular flow occlusion, complete laser actuation was achieved in the mock artery at a laser power of {approx}8 W. We have shown the design and fabrication of an SMP stent and a means of light delivery for photothermal actuation. Though further studies are required to optimize the device and assess thermal tissue damage, photothermal actuation of the SMP stent was demonstrated.

  18. Fabrication and in vitro deployment of a laser-activated shape memory polymer vascular stent

    Directory of Open Access Journals (Sweden)

    Matthews Dennis L

    2007-11-01

    Full Text Available Abstract Background Vascular stents are small tubular scaffolds used in the treatment of arterial stenosis (narrowing of the vessel. Most vascular stents are metallic and are deployed either by balloon expansion or by self-expansion. A shape memory polymer (SMP stent may enhance flexibility, compliance, and drug elution compared to its current metallic counterparts. The purpose of this study was to describe the fabrication of a laser-activated SMP stent and demonstrate photothermal expansion of the stent in an in vitro artery model. Methods A novel SMP stent was fabricated from thermoplastic polyurethane. A solid SMP tube formed by dip coating a stainless steel pin was laser-etched to create the mesh pattern of the finished stent. The stent was crimped over a fiber-optic cylindrical light diffuser coupled to an infrared diode laser. Photothermal actuation of the stent was performed in a water-filled mock artery. Results At a physiological flow rate, the stent did not fully expand at the maximum laser power (8.6 W due to convective cooling. However, under zero flow, simulating the technique of endovascular flow occlusion, complete laser actuation was achieved in the mock artery at a laser power of ~8 W. Conclusion We have shown the design and fabrication of an SMP stent and a means of light delivery for photothermal actuation. Though further studies are required to optimize the device and assess thermal tissue damage, photothermal actuation of the SMP stent was demonstrated.

  19. Tratamiento endovascular del accidente vascular encefálico agudo

    Directory of Open Access Journals (Sweden)

    Dr. G. Francisco Mena

    2013-01-01

    Full Text Available La alternativa de terapia neuroendovascular para un tratamiento del accidente vascular encefálico agudo es una área de la medicina en rápida expansión. El rescate endovascular del infarto cerebral agudo tiene como principal objetivo la rápida reperfusión del vaso ocluido utilizando la trombolisis intra-arterial cerebral y distintos métodos de trombectomía mecánica o colocación permanente de neurostent. El tratamiento neuro-endovascular de la hemorragia subaracnoidea aguda aneurismática también se ha establecido como la terapia de elección e incluye la embolización convencional con coils del aneurisma cerebral roto o utilizando técnica de embolización balón o stent asistido o colocación primaria de stent con tecnología de divertidor de flujo. Además, con la terapia endovascular se puede efectuar angioplastía farmacológica y mecánica del vasoespasmo cerebral.

  20. 裸支架腔内血管重建术治疗孤立性肠系膜上动脉夹层动脉瘤%Percutaneous endovascular reconstruction with endovascular stent placement for isolated spontaneous dissection of the superior mesenteric artery

    Institute of Scientific and Technical Information of China (English)

    苏浩波; 顾建平; 楼文胜; 何旭; 陈亮; 陈国平; 宋进华; 汪涛; 徐克

    2011-01-01

    目的 评价裸支架载瘤动脉腔内血管重建术治疗孤立性肠系膜上动脉夹层的安全性和疗效.方法 2007年至2010年对5例经腹部CT血管成像(CTA)及数字减影血管造影(DSA)明确诊断的肠系膜上动脉夹层动脉瘤患者行裸支架载瘤动脉腔内血管重建术治疗.按照Sakamoto血管影像学分型,Ⅰ、Ⅱ型各1例,Ⅲ型3例.患者术后继续给予抗凝、抗血小板治疗,术后1、3、6个月进行CTA或血管造影随访.结果 5例患者手术均获成功,其中支架联合弹簧圈栓塞2例,双支架重叠技术3例,无并发症发生.4例症状性患者术后3周内症状消失.5例患者术后3 ~ 6个月时肠系膜上动脉CTA及DSA显示动脉瘤腔不显影,支架腔内血流通畅.随访3 ~ 12个月(平均7.8个月)夹层动脉瘤无复发.结论 裸支架载瘤动脉腔内血管重建术是治疗孤立性肠系膜上动脉夹层安全、有效的方法.%Objective To evaluate the safely arid efficacy of percutaneous endovaseular reconstruction with endovaseular slent placement for Isolated spontaneous dissection of the superior mesenteric artery. Methods Five patients with Isolated spontaneous dissection of the superior mesenteric artery were enrolled in tliis study. The diagnosis was confirmed by abdominal computed tomography auglography (CTA ) and percutaneous transcatheter digital subtraction angiography (DSA ) in all the five patients. One asymptomatic case was discovered by medical examination, which was classified to type I (Sakamoto angiographic categorization). The other four cases were admitted to hospital with acute abdominal pain and diarrhea, which were classified to type JI( 1 case ) and type UK 3 cases). Fasting together with antiplatelet and antieoagulation therapy was initially employed. Then, percutaneous endovaseular reconstruction with stenting was carried out and the patients were kept on antiplatelet therapy. Follow-up checkups with CTA or DSA were conducted at 1. 3 and 6

  1. Endovascular treatment of thoracic aortic diseases

    Directory of Open Access Journals (Sweden)

    Davidović Lazar

    2013-01-01

    performed with explantation of stent-graft and open aortic in situ recontruction, followed by esophagectomy and the creation of cervical and gastrical stoma. Conclusion. Having in mind initial results of the 3 main vascular clinics in Belgrade, Serbia, economical situation in our country, as well as the published international results, endovascular treatment of thoracic aortic diseases is indicated in hemodinamicaly unstable patients with acute traumatic aneurysm, or in stabile patients older than 65, as well as in case of chronic diseases of the thoracic aorta in patients with significant comorbid conditions or in patients older than 65 years. Endovascular procedures on the thoracic aorta could be performed, hower, only in high-volume centers with experience in routine open surgery of thoracic aorta.

  2. Endovascular therapy for acute stroke: Quo vadis?

    Directory of Open Access Journals (Sweden)

    Venkatesh S Madhugiri

    2013-01-01

    Full Text Available Endovascular therapy (EVT has gained vogue in the management of patients with acute stroke. Newer stent-retriever devices have led to better recanalization rates. In many centers, EVT is slowly being used as an add on to or in some instances, even as an alternative to intravenous tissue plasminogen activator (IV tPA. The publication of the results of the SYNTHESIS expansion, Interventional Management of Stroke III and Mechanical Retrieval Recanalization of Stroke Clots Using Embolectomy trials in 2013 has questioned the enthusiastic use of EVT in acute stroke. They demonstrate that EVT (using a variety of devices is no superior to IV tPA in the management of acute stroke. In the light of these controversial findings, we review the current status of EVT in the management of acute stroke.

  3. Endovascular treatment of acute ischemic stroke: the end or just the beginning?

    Science.gov (United States)

    Mokin, Maxim; Khalessi, Alexander A; Mocco, J; Lanzino, Giuseppe; Dumont, Travis M; Hanel, Ricardo A; Lopes, Demetrius K; Fessler, Richard D; Ringer, Andrew J; Bendok, Bernard R; Veznedaroglu, Erol; Siddiqui, Adnan H; Hopkins, L Nelson; Levy, Elad I

    2014-01-01

    Various endovascular intraarterial approaches are available for treating patients with acute ischemic stroke who present with severe neurological deficits. Three recent randomized trials-Interventional Management of Stroke (IMS) III, Mechanical Retrieval and Recanalization of Stroke Clots Using Embolectomy (MR RESCUE), and Synthesis Expansion: A Randomized Controlled Trial on Intra-Arterial Versus Intravenous Thrombolysis in Acute Ischemic Stroke (SYNTHESIS Expansion)-evaluated the efficacy of endovascular treatment of acute ischemic stroke and, after failing to demonstrate any significant clinical benefit of endovascular therapies, raised concerns and questions in the medical community regarding the future of endovascular treatment for acute ischemic stroke. In this paper, the authors review the evolution of endovascular treatment strategies for the treatment of acute stroke and provide their interpretation of findings and potential limitations of the three recently published randomized trials. The authors discuss the advantage of stent-retriever technology over earlier endovascular approaches and review the current status and future directions of endovascular acute stroke studies based on lessons learned from previous trials.

  4. Endovascular treatment of popliteal artery aneurysm. Early and midterm results

    Directory of Open Access Journals (Sweden)

    Rodrigo Borges Domingues

    2015-02-01

    Full Text Available OBJECTIVE: to evaluate the efficacy of endovascular repair of popliteal artery aneurysms on maintaining patency of the stent in the short and medium term. METHODS: this was a retrospective, descriptive and analytical study, conducted at the Integrated Vascular Surgery Service at the Hospital da Beneficência Portuguesa de São Paulo. We followed-up 15 patients with popliteal aneurysm, totaling 18 limbs, treated with stent from May 2008 to December 2012. RESULTS: the mean follow-up was 14.8 months. During this period, 61.1% of the stents were patent. The average aneurysm diameter was 2.5cm, ranging from 1.1 to 4.5cm. The average length was 5cm, ranging from 1.5 to 10 cm. In eight cases (47.1%, the lesion crossed the joint line, and in four of these occlusion of the prosthesis occurred. In 66.7% of cases, treatment was elective and only 33.3% were symptomatic patients treated on an emergency basis. The stents used were Viabahn (Gore in 12 cases (66.7%, Fluency (Bard in three cases (16.7%, Multilayer (Cardiatis in two cases (11.1% and Hemobahn (Gore in one case (5.6%. In three cases, there was early occlusion (16.6%. During follow-up, 88.2% of patients maintained antiplatelet therapy. There was no leakage at ultrasound (endoleak. No fracture was observed in the stents. CONCLUSION: the results of this study are similar to other published series. Probably, with the development of new devices that support the mechanical characteristics found on the thighs, there will be improved performance and prognosis of endovascular restoration.

  5. Virtual stenting workflow with vessel-specific initialization and adaptive expansion for neurovascular stents and flow diverters.

    Science.gov (United States)

    Paliwal, Nikhil; Yu, Hongyu; Xu, Jinhui; Xiang, Jianping; Siddiqui, Adnan H; Yang, Xinjian; Li, Haiyun; Meng, Hui

    2016-10-01

    Endovascular intervention using traditional neurovascular stents and densely braided flow diverters (FDs) have become the preferred treatment strategies for traditionally challenging intracranial aneurysms. Modeling stent and FD deployment in patient-specific aneurysms and its flow modification results prior to the actual intervention can potentially predict the patient outcome and treatment optimization. We present a clinically focused, streamlined virtual stenting workflow that efficiently simulates stent and FD treatment in patient-specific aneurysms based on expanding a simplex mesh structure. The simplex mesh is generated using an innovative vessel-specific initialization technique, which uses the patient's parent artery diameter to identify the initial position of the simplex mesh inside the artery. A novel adaptive expansion algorithm enables the acceleration of deployment process by adjusting the expansion forces based on the distance of the simplex mesh from the parent vessel. The virtual stenting workflow was tested by modeling the treatment of two patient-specific aneurysms using the Enterprise stent and the Pipeline Embolization Device (commercial FD). Both devices were deployed in the aneurysm models in a few seconds. Computational fluid dynamics analyses of pre- and post-treatment aneurysmal hemodynamics show flow reduction in the aneurysmal sac in treated aneurysms, with the FD diverting more flow than the Enterprise stent. The test results show that this workflow can rapidly simulate clinical deployment of stents and FDs, hence paving the way for its future clinical implementation.

  6. Endovascular treatment of iliac vein compression syndrome

    Institute of Scientific and Technical Information of China (English)

    MENG Qing-you; LI Xiao-qiang; QIAN Ai-min; SANG Hong-fei; RONG Jian-jie; ZHU Li-wei

    2011-01-01

    Background Iliac vein compression syndrome (IVCS),the symptomatic compression of the left common iliac vein between the right common iliac artery and the vertebrae,is not an uncommon condition.The aim of this research was to retrospectively evaluate long-term outcome and the significance of endovascular treatment in patients with left IVCS.Methods Between January 1997 and September 2008,296 patients received interventional therapy in the left common iliac vein.In the second stage,170 cases underwent saphenous vein high ligation and stripping.Two hundred and thirty-one cases were followed up over a period of 6 to 120 months (average 46 months) and evaluated for symptom improvement with color ultrasound and ascending venography.Results The stenotic or occlusive segments of the left iliac vein were successfully dilated in 285 cases,of whom 272 received stent implantation therapy.Most of the patients achieved satisfactory results on discharge.During the follow-up period,varicose veins were alleviated in 98.7% of the patients,and leg swelling disappeared or was obviously relieved in 84% of cases.About 85% of leg ulcers completely healed.The total patency rate was 91.7% as evaluated with color ultrasound and 91.5% with ascending venography.Conclusions Endovascular treatment of IVCS provides effective symptomatic improvement and good long-term patency in most patients.

  7. Insights on a Giant Aneurysm Treated Endovascularly.

    Science.gov (United States)

    Graziano, Francesca; Iacopino, Domenico Gerardo; Ulm, Arthur John

    2016-07-01

    Background Endovascular treatment with stent-assisted Guglielmi detachable coils is an accepted method for treating intracranial giant aneurysms that otherwise would require more invasive or destructive treatment or could not be treated at all. Nevertheless, there is a paucity of information concerning inner postcoiling aneurysmal changes in human subjects over the long term. We report a postmortem analysis of a patient with a giant aneurysm at the vertebrobasilar junction (VBJ) who was treated endovascularly and studied pathologically 24 months after treatment. Materials and Method The head was removed at autopsy and prefixed in a 10% neutral buffered formalin solution. The brain was gently removed from the skull base after cutting the intracranial nerves and vascular structures. The giant VBJ aneurysm and its relationship with the brainstem, cranial nerves, and vessels were captured photographically and analyzed. Afterward, under operating microscope guidance, the vertebrobasilar system with the aneurysm was gently and carefully detached from the brainstem and carefully analyzed. Results No complete fibrous obliteration of the aneurysm lumen could be detected in our case, and no endothelialization had taken place 24 months after treatment. Conclusions Our findings agree with those of previous similar reports. Coiling, in particular in large or giant aneurysms, may be burdened by the risk of coil compaction and recanalization, but it has the advantage of not affecting the flow in the perforating arteries.

  8. Paraplegia after aortic and superior mesenteric artery stenting for occlusive disease.

    Science.gov (United States)

    Hans, Sachinder S; Ngo, William; McAllister, Michael

    2014-02-01

    Paraplegia after endovascular therapy for aortic and visceral artery occlusive disease is an extremely uncommon occurrence. Two cases of paraplegia after placement of an aortic covered stent for infrarenal aortic stenosis and a superior mesenteric artery stent for chronic visceral ischemia are presented. In both patients, embolization of the arterial supply to the spinal cord was the presumed cause. One patient had a slight recovery after intense physical therapy and rehabilitation. The second patient did not have any recovery from her paraplegia.

  9. Symptomatic stent cast.

    Science.gov (United States)

    Keohane, John; Moore, Michael; O'Mahony, Seamus; Crosbie, Orla

    2008-02-01

    Biliary stent occlusion is a major complication of endoscopic stent insertion and results in repeat procedures. Various theories as to the etiology have been proposed, the most frequently studied is the attachment of gram negative bacteria within the stent. Several studies have shown prolongation of stent patency with antibiotic prophylaxis. We report the case of stent occlusion from a cast of a previously inserted straight biliary stent; a "stent cast" in an 86-year-old woman with obstructive jaundice. This was retrieved with the lithotrypter and she made an uneventful recovery. This is the first reported case of a biliary stent cast.

  10. Symptomatic stent cast.

    LENUS (Irish Health Repository)

    Keohane, John

    2012-02-03

    Biliary stent occlusion is a major complication of endoscopic stent insertion and results in repeat procedures. Various theories as to the etiology have been proposed, the most frequently studied is the attachment of gram negative bacteria within the stent. Several studies have shown prolongation of stent patency with antibiotic prophylaxis. We report the case of stent occlusion from a cast of a previously inserted straight biliary stent; a "stent cast" in an 86-year-old woman with obstructive jaundice. This was retrieved with the lithotrypter and she made an uneventful recovery. This is the first reported case of a biliary stent cast.

  11. Kissing iliac artery stent technique for salvage of a total occlusion of a jailed common iliac artery.

    Science.gov (United States)

    Ishizuka, Shuichi; Habara, Maoto; Nasu, Kenya

    2014-03-01

    A 70-year-old female was admitted to our hospital due to claudication of the left leg. The patient was diagnosed with peripheral artery disease and received endovascular therapy (EVT) with a stent implanted in the right common iliac artery (CIA) at another hospital 3 months earlier. The left CIA was jailed by the stent. We performed EVT for the chronic total occlusion (CTO) of the jailed left CIA. A kissing-stent strategy was selected because the strut could not be fully opened. The wire was crossed through the stent strut, since passing the wire outside of the stent was problematic. A balloon was dilated at the stent strut and further inserted while dilated in order to create a space between the implanted stent and opposite aorta wall. Finally, a wire was successfully crossed outside of the stent in this space. A balloon-expandable stent was implanted at the aorta to left CIA in order to perform the kissing-stent technique. Additionally, a self-expandable stent was deployed at the left external iliac artery. To facilitate kissing-stent technique for a jailed CIA CTO lesion, inserting the balloon while inflated at the bifurcation was useful to create space for advancing the guidewire along the stent.

  12. Newer endovascular tools: a review of experimental and clinical aspects.

    Science.gov (United States)

    Sorenson, Thomas; Brinjikji, Waleed; Lanzino, Giuseppe

    2016-03-01

    The history of treatment of intracranial aneurysms dates back to the late 18th century. These early physicians largely based their crude techniques around "wire insertion alone, galvanopuncture (electrothrombosis), and fili-galvanopuncture (wire insertion together with electrothrombosis)," albeit with overwhelmingly unfavorable outcomes. By the end of the 20th century, treatment options progressed to include two highly effective, and safe, procedures: surgical clipping and endovascular coiling. These methods have been found to be effective treatments for a large portion of aneurysms, but there still exists a subset of patients that do not respond well to these therapies. While much progress has been made in stent-assisted coiling including the development of newer stents aimed at keep the coil ball from protruding into the parent vessel, the introduction of flow diverters has characterized a new phase in the endovascular treatment of intracranial aneurysms. This treatment paradigm is rapidly becoming the treatment of choice for large and complex aneurysms internal carotid artery. Intrasaccular flow diverters such as the Woven EndoBridge device (WEB) and Luna device are showing promise in the treatment of wide neck bifurcation aneurysms. Other newer devices including the pCONus Bifurcating Aneurysm Implant and Endovascular Clip Systems (eCLIPs) are showing promise in small clinical and preclinical studies. As technology improves, newer devices with ingenious designs are constantly being introduced into the clinical arena. Most of these devices try to address the limitations of traditional endovascular methods in regard to providing a safe and effective treatment of wide-necked bifurcation aneurysms. Several large prospective studies are underway and once completed, the role of these newer devices will be better defined. It is easy to anticipate that with advances in 3D techniques and printing, a future in which customized devices are designed based on the individual

  13. A modified technique for Gore Excluder limb deployment in difficult iliac anatomy during endovascular abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    Vourliotakis, George; Katsargyris, Athanasios; Tielliu, Ignace F. J.; Zeebregts, Clark J.; Verhoeven, Eric L. G.

    Complex iliac anatomy including extreme tortuosity constitutes a relative contraindication for endovascular abdominal aortic aneurysm repair with additional risk of limb-graft occlusion. The Gore Excluder limb-graft is a flexible stent-graft, which adapts easily to iliac tortuosity. Nevertheless,

  14. Endovascular treatment of a bleeding secondary aorto-enteric fistula. A case report with 1-year follow-up.

    Science.gov (United States)

    Brountzos, Elias N; Vasdekis, Spyros; Kostopanagiotou, Georgia; Danias, Nikolaos; Alexopoulou, Efthymia; Petropoulou, Konstantina; Gouliamos, Athanasios; Perros, Georgios

    2007-01-01

    We report a patient with life-threatening gastrointestinal bleeding caused by a secondary aorto-enteric fistula. Because the patient had several comorbid conditions, we succesfully stopped the bleeding by endovascular placement of a bifurcated aortic stent-graft. The patient developed periaortic infection 4 months later, but he was managed with antibiotics. The patient is well 1 year after the procedure.

  15. Aneurysm diameter and proximal aortic neck diameter influence clinical outcome of endovascular abdominal aortic repair : A 4-year EUROSTAR experience

    NARCIS (Netherlands)

    Waasdorp, EJ; de Vries, JPPM; Hobo, R; Leurs, LJ; Buth, J; Moll, FL

    2005-01-01

    Our objective was to evaluate the effect of preoperative aneurysm and aortic neck diameter on clinical outcome after infrarenal abdominal endovascular aneurysm repair (EVAR). Data of patients in the European Collaborators Registry on Stent-Graft Techniques for Abdominal Aortic Aneurysm Repair (EUROS

  16. A modified technique for Gore Excluder limb deployment in difficult iliac anatomy during endovascular abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    Vourliotakis, George; Katsargyris, Athanasios; Tielliu, Ignace F. J.; Zeebregts, Clark J.; Verhoeven, Eric L. G.

    2015-01-01

    Complex iliac anatomy including extreme tortuosity constitutes a relative contraindication for endovascular abdominal aortic aneurysm repair with additional risk of limb-graft occlusion. The Gore Excluder limb-graft is a flexible stent-graft, which adapts easily to iliac tortuosity. Nevertheless, th

  17. Endovascular Interventions for Idiopathic Intracranial Hypertension and Venous Tinnitus: New Horizons.

    Science.gov (United States)

    Hui, Ferdinand K; Abruzzo, Todd; Ansari, Sameer A

    2016-05-01

    Pulsatile tinnitus from intracranial venous abnormalities is an uncommon cause of pulse synchronous tinnitus. Endovascular therapies may have applications in many of these disease conditions. They have the advantage of being minimally invasive and may selectively eliminate the site of turbulence. Venous stenting has been used successfully to treat venous stenoses with low complication rates and high success rates in patients with idiopathic intracranial hypertension though randomized controlled data are lacking. Careful exclusion of other causes of tinnitus should be performed before consideration for surgical or endovascular treatment of presumed causative lesions of venous tinnitus.

  18. Endovascular management of thrombosed axillary artery to right atrium hemodialysis graft.

    Science.gov (United States)

    Kabutey, Nii-Kabu; Deso, Steve; Wong, Leslie; Sgroi, Michael D; Kim, Ducksoo

    2014-01-01

    To describe the salvage of a left axillary artery to right atrium hemodialysis graft using endovascular techniques. A 54-year-old man with multiple arteriovenous graft failures presented with a thrombosed left axillary artery to right atrium Gore-tex hemodialysis graft. The graft was salvaged using rheolytic catheter thrombectomy, mechanical thrombectomy, balloon angioplasty, and stenting. This single case report suggests that when axillary to right atrium grafts fail, various endovascular techniques can be employed to salvage the graft and maintain dialysis access. Published by Elsevier Inc.

  19. Endovascular Repair of a Ruptured Aortic Extra-anatomic Bypass Pseudoaneurysm After Previous Coarctation Surgery.

    Science.gov (United States)

    Hörer, Tal; Toivola, Asko

    2015-01-01

    We present a short case of a total endovascular repair of a ruptured thoracic pseudoaneurysm after previous coarctation aortic conduit bypass surgery. A 67-year-old man with two previous coarctation repairs many years ago was admitted with chest pain, dyspnea, and hemoptysis. Computed tomography showed a rupture in the distal anastomosis of the thoracic extra-anatomic graft. Successful treatment was achieved by placement of an endovascular stent graft between the old graft and the native aorta and with a vascular plug occlusion of the native aorta.

  20. Endovascular Treatment of Totally Occluded Superior Mesenteric Artery by Retrograde Crossing via the Villemin Arcade

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Carlo; Rossi, Umberto G., E-mail: urossi76@hotmail.com; Seitun, Sara; Bovio, Giulio [IRCCS San Martino University Hospital-IST-National Institute for Cancer Research, Department of Radiology and Interventional Radiology (Italy); Fornaro, Rosario [IRCCS San Martino University Hospital-IST-National Institute for Cancer Research, Department of Surgery (Italy)

    2013-06-15

    Chronic mesenteric ischemia (CMI) is a rare disorder that is commonly caused by progressive atherosclerotic stenosis or occlusion of one or more mesenteric arteries. Endovascular treatment for symptomatic CMI represents a viable option, especially in high-operative risk patients. We report a case of acute symptomatic CMI with chronic totally occlusion of the superior mesenteric artery (SMA) associated with significant stenosis of celiac trunk (CT) and inferior mesenteric artery (IMA) that underwent endovascular treatment of all the three mesenteric arteries: stenting of CT and IMA stenosis, and recanalization of the SMA occlusion by retrograde crossing via the Villemin arcade.

  1. Endovascular repair for abdominal aortic aneurysm followed by type B dissection.

    Science.gov (United States)

    Shingaki, Masami; Kato, Masaaki; Motoki, Manabu; Kubo, Yoji; Isaji, Toshihiko; Okubo, Nobukazu

    2016-10-01

    An 86-year-old man with an abdominal aortic aneurysm was diagnosed with type B aortic dissection accompanied by a patent false lumen that started at the distal arch of the thoracic aorta and terminated at the left common iliac artery. Meticulous preoperative assessment detected 3 large intimal tears in the descending aorta, abdominal aortic aneurysm, and left common iliac artery. We performed single-stage thoracic and abdominal endovascular aneurysm repair and concomitant axillary-axillary bypass. The abdominal aortic aneurysm with type B aortic dissection was successfully treated using a single-stage endovascular stent graft, without any complications due to the careful preoperative examinations.

  2. Biomechanical issues in endovascular device design.

    Science.gov (United States)

    Moore, James E

    2009-02-01

    The biomechanical nature of the arterial system and its major disease states provides a series of challenges to treatment strategies. Endovascular device design objectives have mostly centered on short-term challenges, such as deployability and immediate restoration of reliable flow channels. The resulting design features may be at odds with long-term clinical success. In-stent restenosis, endoleaks, and loss of device structural integrity (e.g., strut fractures) are all manifestations of a lack of compatibility between the host vessel biomechanical environment and the implant design. Initial attempts to adapt device designs for increased compatibility, including drug-eluting and bioabsorbable stents, barely begin to explore the ways in which implant design can be modulated in time to minimize risk of failure. Biomechanical modeling has the potential to provide a virtual vascular environment in which new designs can be tested for their implications on long-term tissue reaction. These models will be based on high quality, highly resolved imaging information, as well as mechanobiology experiments from the cellular to the whole tissue level. These models can then be extended to incorporate biodegradation mechanics, facilitating the next generations of devices whose designs (including drug delivery profiles) change with time to enhance healing. The possibility of initiating changes in device design or drug release according to information on vascular healing (through clinical intervention or automated methods) provides the opportunity for truly individualized dynamic device design optimization.

  3. PERFORMANCE EVALUATION OF ENDOVASCULAR MYOCARDIUM REVASCULARIZATION IN RENAL TRANSPLANT RECIPIENTS

    Directory of Open Access Journals (Sweden)

    I. G. Ryadovoy

    2012-01-01

    Full Text Available Coronary artery stenting was performed at 75 renal transplant recipients. Diffuse multiple and expressed calcified coronary artery disease took place that created many difficulties during the procedures. In result of endovascular treatments positive dynamics of clinical condition in the nearest postoperative period was marked, tolerance to physical exercise was increased and according to this the functional class of angina was reduced. Cardiac and general mortality after treatment in comparison to the data of foreign authors was lower and comparable with demographic death rate of the population for persons of the same sex and age. 

  4. Endovascular exclusion of aortoesophageal fistula after coarctation extraanatomical bypass.

    Science.gov (United States)

    Myers, Patrick O; Gemayel, Gino; Mugnai, Damiano; Murith, Nicolas; Kalangos, Afksendiyos

    2014-07-01

    Extraanatomical bypass has been advocated as the primary technique in adolescents or adults presenting with aortic coarctation. This approach carries significant morbidity, and graft-related complications may be more important in the young patient population. A 52-year-old man who had previously undergone extraanatomical bypass of aortic coarctation was diagnosed with a distal anastomotic pseudoaneurysm and aortoesophageal fistula. This was managed by proximal bypass plugging with an occluder, endovascular exclusion with a stent-graft in the thoracic descending aorta covering the pseudoaneurysm, and coarctation balloon dilation. Aortoesophageal fistula is a late complication observed after extraanatomical bypass for coarctation. This case illustrates this rare complication.

  5. Stent-assisted coil embolization of intracranial wide-necked aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young-Jun [Bundang CHA Hospital, Department of Diagnostic Radiology, Pochon CHA University College of Medicine, Gyeonggi-do (Korea); Kim, Dong Joon; Suh, Sang Hyun; Lee, Seung-Koo; Kim, Jinna; Kim, Dong Ik [Yonsei University College of Medicine, Severance Hospital, Department of Diagnostic Radiology and Research Institute of Radiological Science, Seoul (Korea)

    2005-09-01

    The endovascular treatment of cerebral aneurysms with coils poses significant technical challenges, particularly with respect to wide-necked aneurysms. We present the results of our initial experiences in using a stent for endovascular treatment of aneurysms, with an emphasis on potential applications, technical aspects, and associated complications. Twenty-three wide-necked aneurysms from 22 patients were treated during the 13-month study period. Seven patients presented with subarachnoid hemorrhage. Aneurysms were located at the internal carotid artery (n=14), the vertebral artery (n=3), the basilar artery (n=5), and the middle cerebral artery (n=1). A Neuroform stent{sup 2} was used for stent-assisted procedures. Premedication with antithrombotic agents was available for unruptured cases. Postprocedural antithrombotic medication was prescribed for all patients. Nineteen aneurysms were primarily stented, followed by coil placement. For five of these aneurysms, stenting was performed subsequent to failure of an attempt to frame with an initial coil. Stenting for the remaining four aneurysms was performed as a rescue procedure to prevent the migration of previously placed coils. Complete occlusion was obtained in ten aneurysms, nearly complete occlusion (95% or more occluded) in 11 aneurysms, and partial occlusion (less than 95% occluded) in one aneurysm. In one aneurysm, we failed to navigate the microcatheter into the aneurysmal sac through the interstices of the stent. Stent thrombosis was noted during the procedure in one patient. Hemorrhagic complication on the 25th day after the procedure was noted in one patient. No procedure-related complications were observed during the procedure or during follow-up in the remaining 20 patients, including seven patients who did not receive antithrombotic agents prior to endovascular treatment owing to recent subarachnoid hemorrhage. To overcome the technical limitation in the coiling of wide-necked aneurysms, stent

  6. Angiographic warning of hemorrhagic transformation after stent retriever thrombectomy procedure

    OpenAIRE

    Vollman, Andrew T; Bruno, Charles A; Dumeer, Shifali; Malone, Hani; Meyers, Philip M

    2013-01-01

    This study reports cerebral angiographic findings observed after stent retriever thrombectomy that is suggestive of a higher risk of hemorrhagic transformation (HT). A woman aged 65–75 presented with a right middle cerebral artery syndrome confirmed by non-contrast CT brain scan. Endovascular revascularization using the Solitaire device was placed across the thromboembolic occlusion and thromboembolectomy was performed. Angiography showed complete recanalization of the left internal carotid a...

  7. Tratamento endovascular de ruptura traumática da aorta torácica descendente Endovascular treatment of traumatic descending thoracic aortic rupture

    Directory of Open Access Journals (Sweden)

    João Roberto Breda

    2007-06-01

    Full Text Available Paciente do sexo feminino, 55 anos de idade, vítima de atropelamento, foi admitida em unidade de emergência, onde se realizou o diagnóstico clínico, radiológico e tomográfico de ruptura traumática da aorta torácica descendente. Diante do achado, a paciente foi encaminhada para tratamento endovascular com colocação de endoprótese auto-expansível (stent pela artéria femoral. O tratamento obteve sucesso, evidenciado pela exclusão da lesão localizada previamente no istmo aórtico. O tratamento endovascular tem sido indicado nas afecções de aorta torácica descendente com bons resultados iniciais. Na ruptura traumática de aorta, a terapêutica endovascular representa uma alternativa aceitável, especialmente devido aos riscos do tratamento operatório convencional.A 55-year-old, female patient who was run over by a motor vehicle was admitted at an emergency room. Clinical, radiological and tomographic diagnosis of traumatic descending aortic thoracic rupture was performed. The patient was referred for endovascular treatment with placement of a self-expandable stent through the femoral artery. Treatment was successful, with exclusion of the lesion previously located in the aortic isthmus. Endovascular treatment has been indicated in the treatment of descending thoracic aortic diseases, with good initial results. In case of traumatic aortic rupture, endovascular treatment is a feasible alternative, especially due to risks offered by the conventional surgical treatment.

  8. Patient-specific simulation of stent-graft deployment within an abdominal aortic aneurysm

    CERN Document Server

    Perrin, David; Avril, Stéphane; Albertini, Jean-Noël; Orgéas, Laurent; Geindreau, Christian; Dumenil, Aurélien; Goksu, Cemil

    2014-01-01

    In this study, finite element analysis is used to simulate the surgical deployment procedure of a bifurcated stent-graft on a real patient's arterial geometry. The stent-graft is modeled using realistic constitutive properties for both the stent and most importantly for the graft. The arterial geometry is obtained from pre-operative imaging exam. The obtained results are in good agreement with the post-operative imaging data. As the whole computational time was reduced to less than 2 hours, this study constitutes an essential step towards predictive planning simulations of aneurysmal endovascular surgery

  9. Osteonecrosis of Femoral Head Occurred after Stent Placement of Femoral Artery

    Directory of Open Access Journals (Sweden)

    Akiyoshi Shimatani

    2014-01-01

    Full Text Available We present a case of osteonecrosis of femoral head (ONFH that occurred after stent angiography of femoral artery for the treatment of arteriosclerosis obliterans (ASO of left inferior limb in a 76-year-old woman. No case of late collapse of femoral head as a complication of endovascular procedure such as stent placement has been previously documented. We considered that ONFH occurred after detaining stent at a junction of left deep femoral artery for the treatment of the ischemia of left lateral and medial femoral circumflex artery.

  10. Endovascular Management of Superior Mesenteric Artery (SMA) Aneurysm – Adequate Access is Essential for Success – Case Report

    Science.gov (United States)

    Tkalčić, Lovro; Budiselić, Berislav; Kovačević, Miljenko; Knežević, Siniša; Kovačić, Slavica; Miletić, Damir; Tomulić, Vjekoslav; Kuhelj, Dimitrij

    2017-01-01

    Summary Background An aneurysm of the superior mesenteric artery (SMA) with a diameter of 2.2 cm was found incidentally on an ultrasound (US) examination in a 26-year-old woman. The only known risk factor was an intracranial aneurysm that was found on her grandmother’s autopsy. Based on pregnancy planning and the current literature, endovascular management with a covered stent was proposed. Case Report Self-expandable, covered stent (Bard, Fluency®) was implanted using a single transfemoral approach. A stiff guidewire and a large sheath distorted the anatomy, which resulted in an incomplete aneurysmal neck covering. In the absence of additional covered stents, the procedure was terminated. Two weeks later, computed tomographic angiography (CTA) confirmed persistent aneurysmal perfusion due to the incomplete neck coverage. A multidisciplinary board opted for a second endovascular attempt, this time with a longer covered stent via the transaxillary approach in order to reduce anatomical distortion. Balloon, expandable, cobalt-chrome covered stent (Jotec, E-ventus BX®) was implanted in the SMA, covering the aneurysmal neck and overlapping the previously implanted covered stent. Angiography confirmed a complete exclusion of the aneurysm. A control US performed three weeks later confirmed a patent covered stent and complete aneurysmal exclusion. There was a mild median nerve damage periprocedurally that resolved in three months. The most recent US control examination, performed eleven months after the procedure, showed an excluded aneurysm and a patent covered stent. There were no clinical signs of bowel ischaemia during the follow-up period. Conclusions Endovascular management of SMAA proved to be safe and efficient. The “access from above” is probably safer and should be considered in the majority of cases with acceptable sizes of access vessels. Mid-term results in our patient are good and life-long follow-up is planned to prevent late complications. PMID

  11. Stent-grafting combined with transcatheter embolization for a ruptured isolated hypogastric artery aneurysm

    Institute of Scientific and Technical Information of China (English)

    DONG Zhi-hui; FU Wei-guo; GUO Da-qiao; XU Xin; CHEN Bin; JIANG Jun-hao; YANG Jue; SHI Zheng-yu; WANG Yu-qi

    2006-01-01

    @@ Rupture of isolated hypogastric artery aneurysm (HAA) is rarely encountered and is associated with a high mortality rate. Conventional surgery can not achieve distal control easily and may cause substantial blood loss, yielding high operative morbidity and mortality. On March 17, 2005, we treated a patient with such a disease successfully by using endovascular stent-grafting combined with transcatheter embolization.

  12. Role of the latest endovascular technology in the treatment of intermittent claudication

    Directory of Open Access Journals (Sweden)

    Ichihashi S

    2014-06-01

    Full Text Available Shigeo Ichihashi, Kimihiko Kichikawa Department of Radiology, Nara Medical University, Kashihara, Nara, Japan Abstract: Intermittent claudication is a serious symptom in patients with peripheral arterial disease, and severely limits activities of daily living. Conservative treatment (optimal medical therapy and exercise rehabilitation programs and revascularization procedures (endovascular treatment [EVT] or open bypass surgery can relieve intermittent claudication. Among these treatment options, EVT has developed dramatically during the past decade, and has enabled physicians to offer less invasive treatment options with increasing durability. EVT for aortoiliac lesions has matured, and its long-term patency now approaches that of open bypass surgery. The latest EVT technologies include drug-eluting stents, stent grafts, drug-coated balloons, and bioresorbable stents. The recently reported patency of stent grafts in the femoropopliteal lesions was comparable with that of the prosthetic bypass graft. In the course of the paradigm shift from bypass surgery to EVT, evidence of any long-term benefit of EVT compared with supervised exercise is still inconclusive. EVT could improve walking performance in the short-term, while supervised exercise could improve walking performance more efficiently in the long-term. Combined treatment with EVT and exercise may offer the most sustainable and effective symptom relief. This paper reviews the relevant literature on the treatment of intermittent claudication, focusing on the latest EVT technologies, and outlines a strategy for achieving long-term benefits. Keywords: endovascular treatment, intermittent claudication, peripheral arterial disease, stent, exercise therapy

  13. Biomechanical Challenges to Polymeric Biodegradable Stents.

    Science.gov (United States)

    Soares, Joao S; Moore, James E

    2016-02-01

    Biodegradable implants have demonstrated clinical success in simple applications (e.g., absorbable sutures) and have shown great potential in many other areas of interventional medicine, such as localized drug delivery, engineered tissue scaffolding, and structural implants. For endovascular stenting and musculoskeletal applications, they can serve as temporary mechanical support that provides a smooth stress-transfer from the degradable implant to the healing tissue. However, for more complex device geometries, in vivo environments, and evolving load-bearing functions, such as required for vascular stents, there are considerable challenges associated with the use of biodegradable materials. A biodegradable stent must restore blood flow and provide support for a predictable appropriate period to facilitate artery healing, and subsequently, fail safely and be absorbed in a controllable manner. Biodegradable polymers are typically weaker than metals currently employed to construct stents, so it is difficult to ensure sufficient strength to keep the artery open and alleviate symptoms acutely while keeping other design parameters within clinically acceptable ranges. These design challenges are serious, given the general lack of understanding of biodegradable polymer behavior and evolution in intimal operating conditions. The modus operandi is mainly empirical and relies heavily on trial-and-error methodologies burdened by difficult, resource-expensive, and time-consuming experiments. We are striving for theoretical advancements systematizing the empirical knowledge into rational frameworks that could be cast into in silico tools for simulation and product development optimization. These challenges are evident when one considers that there are no biodegradable stents on the US market despite more than 30 years of development efforts (and currently only a couple with CE mark). This review summarizes previous efforts at implementing biodegradable stents, discusses the

  14. Intracranial pediatric aneurysms: endovascular treatment and its outcome.

    Science.gov (United States)

    Saraf, Rashmi; Shrivastava, Manish; Siddhartha, Wuppalapati; Limaye, Uday

    2012-09-01

    The aim of this study was to analyze the location, clinical presentation, and morphological characteristics of pediatric aneurysms and the safety, feasibility, and durability of endovascular treatment. The authors conducted a retrospective study of all cases involving patients 18 years old or younger who underwent endovascular treatment for pediatric aneurysms at their institution between July 1998 and July 2010. The clinical presentation, aneurysm location, endovascular management, and treatment outcome were studied. During the study period, 23 pediatric patients (mean age 13 years, range 2 months-18 years) were referred to the authors' department and underwent endovascular treatment for aneurysms. The aneurysms were saccular in 6 cases, dissecting in 4, infectious in 5, and giant partially thrombosed lesions in 8. Fourteen of the aneurysms were ruptured, and 9 were unruptured. Thirteen were in the anterior circulation and 10 in the posterior circulation. The most common location in the anterior circulation was the anterior communicating artery; in the posterior circulation, the most common location was the basilar artery. Saccular aneurysms were the most common type in the anterior circulation; and giant partially thrombosed and dissecting aneurysms were the most common types in the posterior circulation. Coil embolization was performed in 7 cases, parent vessel sacrifice in 10, flow reversal in 3, glue embolization in 2, and stent placement in 1. Immediate angiographic cure was seen in 21 (91%) of 23 patients. Complications occurred in 4 patients, 3 of whom eventually had a good outcome. No patient died. Overall, a favorable outcome was seen in 22 (96%) of 23 patients. Follow-up showed stable occlusion of aneurysms in 96% of the patients. Pediatric aneurysms are rare. Their clinical presentation varies from intracranial hemorrhage to mass effect. They may also be found incidentally. Among pediatric patients with aneurysms, giant aneurysms are relatively common

  15. Endovascular dialysis interventions in the era of DOQI.

    Science.gov (United States)

    Greenberg, Joshua I; Suliman, Ahmed; Angle, Niren

    2008-09-01

    The National Kidney Foundation Dialysis Outcomes and Quality Initiative (DOQI) recommends autogenous fistulae as the preferred access for new dialysis procedures. Unfortunately, despite superior patency rates compared to prosthetic grafts, even autogenous access durability is often undermined by venous stenosis due to intimal hyperplasia at the outflow vein or by central venous stenosis due to long-standing central venous catheters. Salvage interventions, in the form of endovascular treatments such as percutaneous transluminal angioplasty (PTA) and/or stenting, are increasingly utilized for access salvage and maintenance. The objective of this study was to evaluate the efficacy of endovascular dialysis interventions in the era of DOQI. A retrospective review of a database of endovascular interventions for dialysis access during 36 months at an academic medical center was performed. Both central venous and access outflow lesions were included in the analysis. Kaplan-Meier curves and log-rank analysis were used to assess and compare time-dependent variables. Forty-five patients with dialysis access underwent 72 endovascular interventions for access maintenance. There were 27 central venous and 32 outflow endovascular interventions with 98% follow-up. Primary and assisted primary patency rates for outflow balloon PTA were 50% and 72% at 12 months, respectively. There were 1.1 reinterventions required per index outflow PTA procedure. Postintervention primary patency rates for central venous PTA were 30% and 9% at 6 and 12 months, respectively. Postintervention assisted patency for central venous PTA was 100% at 12 months, requiring 1.8 reinterventions per index PTA. Central venous and venous outflow interventions extended overall access patency by 38.5 and 33 months, respectively (p dialysis access. Despite the need for multiple reinterventions and close surveillance, catheter-based interventions positively contribute to dialysis access durability in accordance with

  16. Fine-motor skills testing and prediction of endovascular performance.

    Science.gov (United States)

    Bech, Bo; Lönn, Lars; Schroeder, Torben V; Ringsted, Charlotte

    2013-12-01

    Performing endovascular procedures requires good control of fine-motor digital movements and hand-eye coordination. Objective assessment of such skills is difficult. Trainees acquire control of catheter/wire movements at various paces. However, little is known to what extent talent plays for novice candidates at entry to practice. To study the association between performance in a novel aptitude test of fine-motor skills and performance in simulated procedures. The test was based on manual course-tracking using a proprietary hand-operated roller-bar device coupled to a personal computer with monitor view rotation. A total of 40 test repetitions were conducted separately with each hand. Test scores were correlated with simulator performance. Group A (n = 14), clinicians with various levels of endovascular experience, performed a simulated procedure of contralateral iliac artery stenting. Group B (n = 19), medical students, performed 10 repetitions of crossing a challenging aortic bifurcation in a simulator. The test score differed markedly between the individuals in both groups, in particular with the non-dominant hand. Group A: the test score with the non-dominant hand correlated significantly with simulator performance assessed with the global rating scale SAVE (R = -0.69, P = 0.007). There was no association observed from performances with the dominant hand. Group B: there was no significant association between the test score and endovascular skills acquisition neither with the dominant nor with the non-dominant hand. Clinicians with increasing levels of endovascular technical experience had developed good fine-motor control of the non-dominant hand, in particular, that was associated with good procedural performance in the simulator. The aptitude test did not predict endovascular skills acquisition among medical students, thus, cannot be suggested for selection of novice candidates. Procedural experience and practice probably supplant the influence of innate

  17. Urgent endovascular treatment of proximal right subclavian artery pseudoaneurysm using kissing technique.

    Science.gov (United States)

    Zhang, Mi; Yuan, Ye; Hu, Yali; Zhao, Yi; Liu, Hui; Lu, Huijun

    2015-08-01

    A 50-year old man, sustained a blunt force injury to the chest during an engineering accident, underwent urgent endovascular angioplasty to treat proximal right subclavian artery pseudoaneurysm (RSAP) with a hostile neck in our hospital. Six-month follow-up showed that there was sufficient right carotid artery and right subclavian artery infusion, and the kissing stents were patent. The results show the safety and efficacy of kissing stent technique for RSAP in emergency patients who has no sufficient proximal fixation zone. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Endovascular therapy for renal artery stenoses; Endovaskulaere Therapie der Nierenarterienstenose

    Energy Technology Data Exchange (ETDEWEB)

    Uder, M. [Universitaetsklinik Homburg (Germany). Radiodiagnostik; Humke, U. [Urologische Universitaetsklinik Wuerzburg (Germany)

    2003-12-01

    Percutaneous transluminal balloon angioplasty and stenting for renal artery stenoses have become routine in the day-to-day life of interventional radiologists. New studies, however, have questioned the role of this methodology. This review discusses the technique of endovascular therapy for renal artery stenoses and the impact of the pathoanatomic differences on the outcome of angioplasty or stenting. Furthermore, the current role of revascularisation in the treatment of renal hypertension and renal insufficiency is analyzed and its contribution in competition with other methods is demonstrated. It is the goal of this review to give practical advice how to treat stenoses found in various clinical settings. (orig.) [German] Angioplastie und Stent-Therapie von Verengungen der Nierenarterie gehoeren laengst zum Alltagsgeschaeft interventioneller Radiologen. Neuere Untersuchungen stellen jedoch die klinische Bedeutung der Methode infrage. Der Beitrag beschaeftigt sich zunaechst mit der Technik der endovaskulaeren Therapie von Stenosen der Nierenarterie und damit, wie die Aethiologie der Erkrankung das Ansprechen auf PTA bzw. Stent beeinflusst. Anschliessend wird die aktuelle Bedeutung der Revaskularisation fuer die Behandlung einer renalen Hypertonie und einer Niereninsuffizienz analysiert und gezeigt, wo heute eine Therapie auch in Konkurrenz zu anderen Verfahren sinnvoll ist. Im Ergebnis soll der Artikel praktische Anleitung geben, welche Stenose in verschiedenen klinischen Konstellationen behandelt werden soll. (orig.)

  19. Tomografia computadorizada no diagnóstico da otosclerose fenestral

    Directory of Open Access Journals (Sweden)

    Vicente Andy de Oliveira

    2004-01-01

    Full Text Available OBJETIVO: Identificar os principais achados tomográficos da otosclerose fenestral e avaliar a utilidade da tomografia computadorizada de alta resolução (TCAR, como método diagnóstico dessa osteodistrofia. FORMA DE ESTUDO: Estudo prospectivo multicêntrico com tomografia computadorizada (TC de ossos temporais. MATERIAL E MÉTODO: 54 pacientes com diagnóstico clínico e cirúrgico de otosclerose. Foi realizada uma análise tomográfica, em que foi avaliada a sensibilidade da TC no diagnóstico radiológico da otosclerose fenestral, sendo verificados os principais sítios de lesões dessa doença, como também a sua bilateralidade e simetria. Foram incluídos neste estudo 22 pacientes submetidos à TC de ossos temporais para investigação de outras afecções otológicas, que constituíram o grupo controle. RESULTADOS: A TC foi positiva em 87% dos pacientes (77% das orelhas. Os achados tomográficos foram bilaterais na maioria dos casos (78,7%, e o foco fenestral mais prevalente foi o foco anterior à janela oval (FAJO. CONCLUSÕES: A TC apresentou um alto índice de positividade e o FAJO foi o foco mais prevalente nessa população, podendo ser considerado um achado tomográfico altamente sugestivo de otosclerose.

  20. Extra-anatomic endovascular repair of an abdominal aortic aneurysm with a horseshoe kidney supplied by the aneurysmal aorta.

    Science.gov (United States)

    Rey, Jorge; Golpanian, Samuel; Yang, Jane K; Moreno, Enrique; Velazquez, Omaida C; Goldstein, Lee J; Chahwala, Veer

    2015-07-01

    Abdominal aortic aneurysm complicated by a horseshoe kidney (HSK, fused kidney) represents a unique challenge for repair. Renal arteries arising from the aneurysmal aorta can further complicate intervention. Reports exist describing the repair of these complex anatomies using fenestrated endografts, hybrid open repairs (debranching), and open aneurysmorrhaphy with preservation of renal circulation. We describe an extra-anatomic, fully endovascular repair of an abdominal aortic aneurysm with a HSK partially supplied by a renal artery arising from the aneurysm. We successfully applied aortouni-iliac endografting, femorofemoral bypass, and retrograde renal artery perfusion via the contralateral femoral artery to exclude the abdominal aortic aneurysm and preserve circulation to the HSK.

  1. Endovascular Therapy in Trauma

    Science.gov (United States)

    2014-11-23

    it is worth reviewing that endovascular techniques involve over-the- wire access (percutaneous or direct exposure) to the arte- rial or venous system...parameters such as serum lactate, pH, pCO2, and central , cerebral and coronary perfusion in animal models of hemorrhagic shock have been shown to improve...wire at its end point on a draped end table helps to keep wire position during the procedure. The arterial line catheter is removed and a 12Fr

  2. Endovascular treatment of hepatic artery aneurysm in a patient with Ehlers-Danlos syndrome. Case report.

    Science.gov (United States)

    Casana, R; Nano, G; Dalainas, I; Tealdi, D G

    2004-09-01

    Ehlers-Danlos syndrome (EDS) is a rare, variably inherited disorder affecting connective tissue. Patients with EDS often develop aneurysms of the thoracic and abdominal aorta as well as the visceral arteries. We report our experience with an elective endovascular exclusion of an hepatic artery aneurysm in a 26-year-old female patient with EDS type IV. A balloon-expandable 4x26 mm stent-graft was placed in the common hepatic artery, excluding the aneurysm. The follow-up at the 2, 6 and 18 months showed the patency of the common hepatic artery, the absence of endo-leak and the right location of the stent-graft. In EDS patients, the endovascular treatment could be preferable to open surgery because of the minimum trauma.

  3. Subintimal stent placement in patients with long segment occlusion of the iliac artery

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ho Jung; Kim, Young Hwan; Kim, Si Hyung; Ko, Sung Min; Choi, Jin Soo; Lee, Hyun Jin; Kim, Hyung Tae; Jo, Won Hyun [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of); Kim, Yong Joo [Andong General Hospital, Andong (Korea, Republic of)

    2008-01-15

    We evaluated the technical feasibility and clinical efficacy of subintimal stent placement for long segment occlusion of the iliac artery. From March 2003 to February 2007, subintimal stent placement for long segment occlusion of the iliac artery of 24 limbs in 22 patients was analyzed retrospectively. Endovascular access was performed via the ipsilateral femoral artery in 7 cases, via the contralateral femoral artery in 6 cases, via both femoral arteries in 10 cases and via the brachial artery in one case. The SAFARI (subintimal arterial flossing with antegrade-retrograde intervention) technique using a microcatheter was performed to recannalize iliac artery occlusion in three cases. Medical records were reviewed for the collection of follow-up data. The stent patency rate was analyzed by use of the Kaplan-Meier method. Subintimal stent placement was technically successful in 23 of 24 procedures (95.8%). The mean ankle-brachial index (ABI) increased form 0.26 to 0.82. The Fontaine classification was improved after stent placement in all patients. Major complications occurred in four procedures: three distal embolizations and one arterial rupture. All of the complications were successfully treated by endovascular intervention. The primary stent patency rates at 6-months, 1-, 2-and 3-years were 95%, 88%, 88% and 88%, respectively. Subintimal stent placement is a safe and effective treatment for long segment occlusion of the iliac artery.

  4. Changes in inflammatory response after endovascular treatment for type B aortic dissection.

    Directory of Open Access Journals (Sweden)

    Bernice L Y Cheuk

    Full Text Available This present study aims to investigate the changes in the inflammatory markers after elective endovascular treatment of Type B aortic dissection with aneurysm, as related to different anatomical features of the dissection flap in the paravisceral perfusion. Consecutive patients with type B aortic dissections with elective endovascular stent graft repair were recruited and categorized into different groups. Serial plasma levels of cytokines (Interleukin-1β, -6, -8, -10, TNF-α, chemokines (MCP-1, and serum creatinine were monitored at pre-, peri- and post-operative stages. The length of stent graft employed in each surgery was retrieved and correlated with the change of all studied biochemical parameters. A control group of aortic dissected patients with conventional medication management was recruited for comparing the baseline biochemical parameters. In total, 22 endovascular treated and 16 aortic dissected patients with surveillance were recruited. The endovascular treated patients had comparable baseline levels as the non-surgical patients. There was no immediate or thirty day-mortality, and none of the surgical patients developed post-operative mesenteric ischaemia or clinically significant renal impairment. All surgical patients had detectable pro-inflammatory mediators, but none of the them showed any statistical significant surge in the peri-operative period except IL-1β and IL-6. Similar results were obtained when categorized into different groups. IL-1β and IL-6 showed maximal levels within hours of the endovascular procedure (range, 3.93 to 27.3 higher than baseline; p = 0.001, but returned to baseline 1 day post-operatively. The change of IL-1β and IL-6 at the stent graft deployment was statistically greater in longer stent graft (p>0.05. No significant changes were observed in the serum creatinine levels. In conclusion, elective endovascular repair of type B aortic dissection associated with insignificant changes in

  5. Fenestration system energy performance research, implementation, and international harmonization

    Energy Technology Data Exchange (ETDEWEB)

    McGowan, Raymond F [National Fenestration Rating Council, Greenbelt, MD (United States)

    2014-12-23

    The research conducted by the NFRC and its contractors adds significantly to the understanding of several areas of investigation. NFRC enables manufacturers to rate fenestration energy performance to comply with building energy codes, participate in ENERGY STAR, and compete fairly. NFRC continuously seeks to improve its ratings and also seeks to simplify the rating process. Several research projects investigated rating improvement potential such as • Complex Product VT Rating Research • Window 6 and Therm 6 Validation Research Project • Complex Product VT Rating Research Conclusions from these research projects led to important changes and increased confidence in the existing NFRC rating process. Conclusions from the Window 6/Therm 6 project will enable window manufacturers to rate an expanded array of products and improve existing ratings. Some research lead to an improved new rating method called the Component Modeling Approach. A primary goal of the CMA was a simplification of the commercial energy rating process to increase participation and make the commercial industry more competitive and code compliant. The project below contributed towards CMA development: • Component Modeling Approach Condensation Resistance Research NFRC continues to implement the Component Modeling Approach program. The program includes the CMA software tool, CMAST, and several procedural documents to govern the certification process. This significant accomplishment was a response the commercial fenestration industry’s need for a simplification of the present NFRC energy rating method (named site built). To date, most commercial fenestration is self-rated by a variety of techniques. The CMA enables commercial fenestration manufacturers to rate according to the NFRC 100/200 as most commercial energy codes require. International Harmonization NFRC achieved significant international harmonization success by continuing its licensing agreements with the Australian Fenestration

  6. Development of an in vitro porcine aorta model to study the stability of stent grafts in motor vehicle accidents.

    Science.gov (United States)

    Darvish, Kurosh; Shafieian, Mehdi; Romanov, Vasily; Rotella, Vittorio; Salvatore, Michael D; Blebea, John

    2009-04-01

    Endovascular stent grafts for the treatment of thoracic aortic aneurysms have become increasingly utilized and yet their locational stability in moderate chest trauma is unknown. A high speed impact system was developed to study the stability of aortic endovascular stent grafts in vitro. A straight segment of porcine descending aorta with stent graft was constrained in a custom-made transparent urethane casing. The specimen was tested in a novel impact system at an anterior inclination of 45 deg and an average deceleration of 55 G, which represented a frontal automobile crash. Due to the shock of the impact, which was shown to be below the threshold of aortic injury, the stent graft moved 0.6 mm longitudinally. This result was repeatable. The presented experimental model may be helpful in developing future grafts to withstand moderate shocks experienced in motor vehicle accidents or other dynamic loadings of the chest.

  7. Iatrogenic subclavian artery pseudoaneurysm close to the origin of the vertebral artery: an endovascular strategy

    Institute of Scientific and Technical Information of China (English)

    XU Gao-feng; Dae Chul Suh

    2006-01-01

    Subclavian artery pseudoaneurysm that induced from central venous catheterization through the internal jugular vein is relatively uncommon. However, the management of subclavian artery pseudoaneurysm remains a challenge because of their non-compressibility of deep locality and relationship to important surrounding anatomy, such as the origin of vertebral artery. In this paper, the authors report a patient with larger iatrogenic subclavian arterial pseudoaneurysm near the origin of vertebral artery, that was treated successfully by endovascular covered stent and coils.

  8. Endovascular repair of descending thoracic aortic aneurysm via midsternotomy and without extracorporeal circulation.

    Science.gov (United States)

    Abad, C; Garzon, G; Ponce, G; Reyes, R; Rodriguez, D

    2003-12-01

    A 68-year-old man with peripheral vascular disease and associated risk factors, was diagnosed by CT-scan and aortography with an atherosclerotic descending thoracic aortic aneurysm. The patient was treated by successful endovascular grafting of the aneurysm using a midsternotomy incision and the insertion of a thoracic stent-graft through a T-Dacron tube sutured in the ascending aorta, without the aid of cardiopulmonary bypass.

  9. Vertebral artery pseudoaneurysms secondary to blunt trauma: Endovascular management by means of neurostents and flow diverters.

    Science.gov (United States)

    Cohen, José E; Gomori, John M; Rajz, Gustavo; Rosenthal, Guy; El Hassan, Hosni Abu; Moscovici, Samuel; Itshayek, Eyal

    2016-10-01

    Extracranial vertebral pseudoaneurysms that develop following blunt trauma to the cervical area may have a benign course; however, embolic or ischemic stroke and progressive pseudoaneurysm enlargement may occur. We review the presentation and endovascular management of pseudoaneurysms of the cervical vertebral artery (VA) due to blunt trauma in nine patients (eight male, mean age 27years). Pseudoaneurysms occurred in dominant vessels in seven patients and coexisted with segmental narrowing in six. We favored endovascular intervention during the acute phase only in cases with significant narrowing of a dominant VA, especially when anticoagulation was contraindicated. Four patients were treated during the acute stage (contraindication to anticoagulation, mass effect, severely injured dominant VA/impending stroke); five during the chronic phase (pseudoaneurysm growth, ischemic stroke on aspirin prophylaxis, patient preference). Reconstructive techniques were favored over deliberate endovascular occlusion when dominant vessels were involved. Arterial reconstruction was performed in eight of nine patients using a flow-diverter implant (5 patients), stent-assisted coiling (1), overlapping stent implant (1), or implantation of a balloon-expandable stent (1). Deliberate VA occlusion with coils was performed in one of nine patients due to suboptimal expansion of the stented artery after flow-diverter implant. No neurological complications occurred during follow-up. All cases treated by reconstructive techniques showed complete, persistent pseudoaneurysm occlusion and full arterial patency. Endovascular therapy of traumatic VA pseudoaneurysms using neurostents and flow-diverters resulted in occlusion of the pseudoaneurysms, preservation of the parent vessel, and no periprocedural or delayed clinical complications, supporting the feasibility and safety of the approach. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Endovascular management of symptomatic cerebral malperfusion due to carotid dissection after type A aortic dissection repair.

    Science.gov (United States)

    Casana, R; Tolva, V; Majnardi, A Robecchi; Bianchi, P G; Addobati, L; Bertoni, G B; Cireni, L V; Silani, V

    2011-10-01

    Type A acute aortic dissection is a surgical emergency, and supra-aortic trunk involvement may be complicated by stroke in 6% to 20% of cases. A 66-year-old Caucasian female patient underwent a composite repair of the ascending aorta for type A aortic dissection. Postoperative period was complicated by episodes of "drop attack." Doppler ultrasound of supra-aortic trunks revealed an intimal flap occluding right internal carotid artery. Multiple stenting was performed from carotid bifurcation to internal carotid artery in order to exclude the dissection intimal flap. After endovascular procedure physiatrist considered that motor functional improvement was better than expected, and we support that endovascular resolution of carotid malperfusion led to a better outcome. According to other experience, endovascular procedure resulted as a safe and effective way. Moreover, ultrasound monitoring of supra-aortic trunks in postoperative period is recommended.

  11. Coagulopathy associated with sac reperfusion for reversing paraplegia after endovascular repair of type II thoracoabdominal aneurysm.

    Science.gov (United States)

    Lioupis, Christos; Katsanos, Konstantinos; Clough, Rachel; Matharu, Nick; Modarai, Bijan; Carrell, Tom; Taylor, Peter

    2013-11-01

    Sac perfusion may be helpful in preventing or reversing spinal cord injury after endovascular repair of thoracoabdominal aneurysms and it has been used as an adjunct to the standard physiologic measures of sustained hypertension and cerebrospinal fluid drainage. Coagulopathy as a result of endoleak after endovascular aneurysm repair has been reported, and very rare cases of treatment after repair of these endoleaks have been described. We report a 73-year-old man who had endovascular repair of a type II thoracoabdominal aneurysm with a branched stent graft. Sac reperfusion was initiated to manage postoperative paraplegia. The paraplegia partially resolved but severe hemorrhagic complications developed that were attributed to sac perfusion-related hyperfibrinolysis. Discontinuation of sac perfusion resolved the coagulopathy but resulted in paraplegia.

  12. Experience of endovascular treatment of occlusion-stenotic lesions of cerebral arteries

    Directory of Open Access Journals (Sweden)

    Cherednichenko Yu.V.

    2016-03-01

    Full Text Available Objective — to evaluate the efficacy of endovascular techniques in the treatment of occlusion and stenotic lesions of the brachiocephalic and cerebral arteries, to define the ways of complications prevention. Materials and methods. 594 patients with occlusion and stenotic lesions of the brachiocephalic and cerebral arteries were operated by endovascular methods in endovascular center of Dnipropetrovsk Regional Clinical Hospital named after I.I. Mechnikov. 688 endovascular operations were carried out. Most part of the operations are carotid stenting (423 operations. All of these operations were carried out with the usage of different types of antiembolic protection systems: distal, proximal or their combination. Intracranial segments of cerebral arteries were operated in 43 cases. 169 operations of stenting of vertebral arteries in extracranial segments were performed. Subclavian arteries and brachiocephal truncus were operated in 53 cases. Results. Total removal of stenosis was achieved in 588 cases (98.99%. 509 patients (85.69% of cases had improvement in neurological status (on a scale NIHHS, Mrs., MoCA. 77 (12.96% patients had no deterioration of neurological status. Postoperative mortality was 1.01%. Common level of other complications was 4.3 %: cerebral complications - 2.7%. Discussion. The results of the endovascular treatment of occlusion and stenotic lesions of the cerebral arteries show high efficacy and low complication level. The ways of reduction complications level are identified. They are in a differentiated selection of antiembolic protection method, endovascular treatment planning, based on monitoring of changes in the brain hemoperfusion, the emphasis is on the use of the special neurologic deviсes. Conclusions. Endovascular treatment of occlusion and stenotic lesions of the cerebral arteries is effective with a small risk of complications. Risk can be reduced further by the differential choice of antiembolic protection

  13. Use of Micropatterned Thin Film Nitinol in Carotid Stents to Augment Embolic Protection

    Directory of Open Access Journals (Sweden)

    Mahdis Shayan

    2016-12-01

    Full Text Available Stenting is an alternative to endarterectomy for the treatment of carotid artery stenosis. However, stenting is associated with a higher risk of procedural stroke secondary to distal thromboembolism. Hybrid stents with a micromesh layer have been proposed to address this complication. We developed a micropatterned thin film nitinol (M-TFN covered stent designed to prevent thromboembolism during carotid intervention. This innovation may obviate the need or work synergistically with embolic protection devices. The proposed double layered stent is low-profile, thromboresistant, and covered with a M-TFN that can be fabricated with fenestrations of varying geometries and sizes. The M-TFN was created in multiple geometries, dimensions, and porosities by sputter deposition. The efficiency of various M-TFN to capture embolic particles was evaluated in different atherosclerotic carotid stenotic conditions through in vitro tests. The covered stent prevented emboli dislodgement in the range of 70%–96% during 30 min duration tests. In vitro vascular cell growth study results showed that endothelial cell elongation, alignment and growth behaviour silhouettes significantly enhance, specifically on the diamond-shape M-TFN, with the dimensions of 145 µm × 20 µm and a porosity of 32%. Future studies will require in vivo testing. Our results demonstrate that M-TFN has a promising potential for carotid artery stenting.

  14. Use of Micropatterned Thin Film Nitinol in Carotid Stents to Augment Embolic Protection

    Science.gov (United States)

    Shayan, Mahdis; Jankowitz, Brian T.; Shridhar, Puneeth; Chun, Youngjae

    2016-01-01

    Stenting is an alternative to endarterectomy for the treatment of carotid artery stenosis. However, stenting is associated with a higher risk of procedural stroke secondary to distal thromboembolism. Hybrid stents with a micromesh layer have been proposed to address this complication. We developed a micropatterned thin film nitinol (M-TFN) covered stent designed to prevent thromboembolism during carotid intervention. This innovation may obviate the need or work synergistically with embolic protection devices. The proposed double layered stent is low-profile, thromboresistant, and covered with a M-TFN that can be fabricated with fenestrations of varying geometries and sizes. The M-TFN was created in multiple geometries, dimensions, and porosities by sputter deposition. The efficiency of various M-TFN to capture embolic particles was evaluated in different atherosclerotic carotid stenotic conditions through in vitro tests. The covered stent prevented emboli dislodgement in the range of 70%–96% during 30 min duration tests. In vitro vascular cell growth study results showed that endothelial cell elongation, alignment and growth behaviour silhouettes significantly enhance, specifically on the diamond-shape M-TFN, with the dimensions of 145 µm × 20 µm and a porosity of 32%. Future studies will require in vivo testing. Our results demonstrate that M-TFN has a promising potential for carotid artery stenting. PMID:27983574

  15. Endovascular Management of Vascular Injury during Transsphenoidal Surgery.

    Science.gov (United States)

    Cinar, C; Bozkaya, H; Parildar, M; Oran, I

    2013-03-01

    Vascular injury is an unusual and serious complication of transsphenoidal surgery. We aimed to define the role of angiography and endovascular treatment in patients with vascular injuries occurring during transsphenoidal surgery. During the last ten-year period, we retrospectively evaluated nine patients with vascular injury after transsphenoidal surgery. Eight patients were symptomatic due to vascular injury, while one had only suspicion of vascular injury during surgery. Four patients presented with epistaxis, two with subarachnoid hemorrhage, one with exophthalmos, and one with hemiparesia. Emergency angiography revealed a pseudoaneurysm in four patients, contrast extravasation in two, vessel dissection in one, vessel wall irregularity in one, and arteriovenous fistula in one. All patients but one were treated successfully with parent artery occlusion, with one covered stent implantation, one stent-assisted coiling method, while one patient was managed conservatively. One patient died due to complications related to the primary insult without rebleeding. Vascular injuries suspected intra or postoperatively must be investigated rapidly after transsphenoidal surgery. Endovascular treatment with parent artery occlusion is feasible with acceptable morbidity and mortality rates in the treatment of vascular injuries occurring in transsphenoidal surgery.

  16. Hybrid Endovascular Aorta Repair with Simultaneous Supra-aortic Branch or Iliac Branch Revascularization

    Institute of Scientific and Technical Information of China (English)

    Yue-hong Zheng; Nim Choi; Hong-ru Deng; CU Kouk; Kun Yu; Furtado Rui

    2009-01-01

    Objective To describe a hybrid endovascular procedure for aorta repair with different kinds of bypass followed by concomitant placement of stent graft in the aorta.Methods From June 2007 to May 2008,5 consecutive patients who presented with aortic aneurysm or dissection were treated with a new hybrid aorta repair technique.Complete surgical rerouting of supra-aortic vessels was simultaneously created by endovascular repair of aortic arch aneurysm with stent graft.Hybrid left carotid-subclavian bypass with stent graft deployment covering the ostium of the left subclavian artery was performed in a Debakey type Ⅲ aortic dissection case.The supra-aortic branch was revascularized in 2 cases from ascending aorta to bilateral common carotid arteries using a 16-8 mm bifurcated graft,then total aortic arch and descending artery was occluded with stent-graft.The left carotid artery to the left subclavian artery bypass was created in 1 case,followed by stent-graft deployment.Two cases of infrarenal abdominal aortic aneurysm underwent left external iliac artery to left internal iliac artery bypass by a retroperineal route,then hybrid procedure was performed with bifurcated stent-graft.All stent grafts were deployed via a retrograde femoral artery approach in 5 patients.Results Technical success with complete aneurysmal exclusion was achieved in all patients.There was no incidence of endoleak.During a follow-up period of 2 to 10 months,documented perioperative neurologic events did not occur in all patients.One patient suffered from adult respiratory distress syndrome.After received tracheostomy,he recovered later.There was one death resulting from a postoperative myocardial infarction.Conclusion Hybrid arch repair provides an alternative therapy to patients otherwise considered prohibitively high risk for traditional open arch and thoracoabdominal aorta repair.

  17. Recanalization of the lower leg. PTA or stent?; Rekanalisation am Unterschenkel. PTA oder Stent

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Huelsbeck, S. [Medizinischer Klinikverbund Flensburg, Ev.-Luth. Diakonissenanstalt zu Flensburg, Zentrum fuer Gesundheit und Diakonie, Abt. Diagnostische und Interventionelle Radiologie/Neuroradiologie, Flensburg (Germany)

    2010-01-15

    Percutaneous transluminal angioplasty (PTA) and stent placement are currently accepted methods for endovascular treatment of critical limb ischemia, if infragenual vessels are involved. Outcome results in high technical success and satisfactory clinical results for treatment of infrapopliteal lesions with regard to patency rates and amputation-free survival. These treatment modalities are also safe for the patients. The question whether PAT alone or additional stent placement is the better choice, is still unanswered due to limited data. (orig.) [German] Die perkutane transluminale Angioplastie (PTA) und die Stentimplantation stellen inzwischen akzeptierte Methoden zur Behandlung der kritischen Extremitaetenischaemie bei Beteiligung infragenualer Gefaesse dar. Diese Behandlungsmodalitaeten haben eine hohe technische Erfolgsrate, sind sicher fuer den Patienten und erbringen zufrieden stellende klinische Ergebnisse zur Therapie infrapoplitealer Laesionen hinsichtlich Offenheitsrate und amputationsfreiem Ueberleben. Die Frage, ob eine alleinige PTA oder die Stentimplantion besser ist, kann anhand der begrenzten derzeitigen Datenlage zur Zeit noch nicht hinreichend beantwortet werden. (orig.)

  18. Trans-Stent B-Mode Ultrasound and Passive Cavitation Imaging.

    Science.gov (United States)

    Haworth, Kevin J; Raymond, Jason L; Radhakrishnan, Kirthi; Moody, Melanie R; Huang, Shao-Ling; Peng, Tao; Shekhar, Himanshu; Klegerman, Melvin E; Kim, Hyunggun; McPherson, David D; Holland, Christy K

    2016-02-01

    Angioplasty and stenting of a stenosed artery enable acute restoration of blood flow. However, restenosis or a lack of re-endothelization can subsequently occur depending on the stent type. Cavitation-mediated drug delivery is a potential therapy for these conditions, but requires that particular types of cavitation be induced by ultrasound insonation. Because of the heterogeneity of tissue and stochastic nature of cavitation, feedback mechanisms are needed to determine whether the sustained bubble activity is induced. The objective of this study was to determine the feasibility of passive cavitation imaging through a metal stent in a flow phantom and an animal model. In this study, an endovascular stent was deployed in a flow phantom and in porcine femoral arteries. Fluorophore-labeled echogenic liposomes, a theragnostic ultrasound contrast agent, were injected proximal to the stent. Cavitation images were obtained by passively recording and beamforming the acoustic emissions from echogenic liposomes insonified with a low-frequency (500 kHz) transducer. In vitro experiments revealed that the signal-to-noise ratio for detecting stable cavitation activity through the stent was greater than 8 dB. The stent did not significantly reduce the signal-to-noise ratio. Trans-stent cavitation activity was also detected in vivo via passive cavitation imaging when echogenic liposomes were insonified by the 500-kHz transducer. When stable cavitation was detected, delivery of the fluorophore into the arterial wall was observed. Increased echogenicity within the stent was also observed when echogenic liposomes were administered. Thus, both B-mode ultrasound imaging and cavitation imaging are feasible in the presence of an endovascular stent in vivo. Demonstration of this capability supports future studies to monitor restenosis with contrast-enhanced ultrasound and pursue image-guided ultrasound-mediated drug delivery to inhibit restenosis.

  19. Other endovascular methods of treating the diabetic foot.

    Science.gov (United States)

    Peeters, P; Keirse, K; Verbist, J; Deloose, K; Bosiers, M

    2009-06-01

    Critical limb ischemia (CLI) is an endstage manifestation of peripheral artery disease (PAD) and typically describes patients with ischemic rest pain (Rutherford Category 4), or patients with ischemic skin lesions, either ulcers or gangrene (Rutherford Category 5-6). CLI due to infrapopliteal lesions is often not a good indication for infrageniculate bypass surgery placement, due to the presence of prohibitive comorbidities, inadequate conduit, and lack of suitable distal targets for revascularization. Therefore, CLI patients due to blockage of below-the-knee arteries are in benefit of the endovascular approach. Infrapopliteal PTA became feasible with the introduction of low-profile peripheral balloon systems and the use of coronary balloons. Stent implantation, however, is generally reserved for cases with a suboptimal outcome after PTA (i.e. >50% residual stenosis, flow-limiting dissection). Because of the fear that early thrombosis and late luminal loss due to intimal hyperplasia formation will potentially lead to insufficient long-term patency rates, efforts to extend the range of endovascular approaches to CLI are presently focused on. Cryoplasty, scoring balloon angioplasty, excimer laser therapy and atherectomy using different types of atherectomy devices have been introduced. The current article provides an overview of the endovascular treatment strategies for infrapopliteal lesions in patients with CLI.

  20. Implantation study of a tissue-engineered self-expanding aortic stent graft (bio stent graft) in a beagle model.

    Science.gov (United States)

    Kawajiri, Hidetake; Mizuno, Takeshi; Moriwaki, Takeshi; Iwai, Ryosuke; Ishibashi-Ueda, Hatsue; Yamanami, Masashi; Kanda, Keiichi; Yaku, Hitoshi; Nakayama, Yasuhide

    2015-03-01

    The use of stent grafts for endovascular aortic repair has become an important treatment option for aortic aneurysms requiring surgery. This treatment has achieved excellent outcomes; however, problems like type 1 endoleaks and stent graft migration remain. Bio stent grafts (BSGs), which are self-expanding stents covered with connective tissue, were previously developed using "in-body tissue architecture" technology. We assessed their early adaptation to the aorta after transcatheter implantation in a beagle model. BSGs were prepared by subcutaneous embedding of acryl rods mounted with self-expanding nitinol stents in three beagles for 4 weeks (n = 3/dog). The BSGs were implanted as allografts into infrarenal abdominal aortas via the femoral artery of three other beagles. After 1 month of implantation, aortography revealed no stenosis or aneurysmal changes. The luminal surface of the BSGs was completely covered with neointimal tissue, including endothelialization, without any thrombus formation. The cover tissue could fuse the luminal surface of the native aorta with tight conjunctions even at both ends of the stents, resulting in complete impregnation of the strut into the reconstructed vascular wall, which is expected to prevent endoleaks and migration in clinical applications.

  1. LONG-TERM OUTCOMES OF FENESTRATED DISCECTOMY FOR LUMBAR DISC

    Institute of Scientific and Technical Information of China (English)

    PAN Yu-tao; CAO Peng; LIANG Yu; GONG Yao-cheng; ZHENG Tao; ZHANG Xing-kai; WU Wen-jian

    2008-01-01

    Objective To evaluate the long-term outcomes of fenestrated discectomy for lumbar disc herniation and analyze the correlative influence factors.Methods Eighty-two cases of lumbar disc herniation, from February 1996 to May 1999, were retrospectively studied. All patients were treated with simple fenestrated discectomy. The average follow-up time was 8 years and 7 months (from 7 years to10 years and 3months). There were 13, 38 and 31 cases at L3-L4, L4-L5 and L5-S1 level, respectively.Results The average scales before operation were as following: Japanes Orthopaedics Association (JOA) scale 6.5 (5-9), visual analysis scale (VAS) of low back pain 4.8 (0-8), and VAS of sciatica 7.2 (4-10). At the final follow-up, the above parameters were 13.2 (10-14), 1.8 (0-10) and 1.2 (0-7), respectively. The average increase ratio of JOA scale was 78.8%. The average disc-vertebra height ratio (Mochida method) was 80.2%. At the final follow-up, 7 cases reoccurred disc herniation. The final clinical satisfaction rate was 80% (modified Macnab method).Conclusion With appropriate surgical indications, the successful long-term outcomes could be expected with fenestrated discectomy. Discectomy improves sciatica to a greater extent than low back pain. The occurrence of low back pain is related to intervertebral disc height, segment stability, disc degeneration, and lumbar muscle disability.

  2. Idiopathic Fenestrated Complex Syndactyly in a Unique Crisscross Fashion.

    Science.gov (United States)

    Williams, Benjamin R; Van Heest, Ann E

    2016-12-01

    This case presents surgical treatment of a unique form of syndactyly: an isolated fenestrated, complex, crisscross syndactyly of the right middle and ring fingers. A 2-year-old boy presented with the ring finger lying dorsal and the middle finger lying volar, with the middle phalanges syndactylized. A surgical release was performed with a subsequent z-plasty, 2 years later, for scar elongation. At the age of 4, he has essentially full function of his hand with minimal limitations. This case demonstrates that 2 digits that were syndactylized in a coronal plane (ring finger dorsal and middle finger volar) can be successfully surgically separated.

  3. Unilateral hydrocephalus in paediatric patients, a trial of endoscopic fenestration.

    Directory of Open Access Journals (Sweden)

    Kumar R

    1999-10-01

    Full Text Available Two uncommon cases of unilateral, asymmetrical hydrocephalus secondary to membranous occlusion of foramen of monro are described. Both the cases presented with clinical features of raised intracranial pressure and their cranial computerized scans (CT revealed asymmetrical dilatation of lateral ventricles with displacement of septum pellucidum towards the side of smaller ventricle. Neuroendoscopic fenestration of septum pellucidum and foramen of monro was tried in both the cases, which remained successful in first, while the second case required unilateral ventriculoperitoneal shunt, due to failed endoscopic negotiation of narrowed foramen of monro and intraoperative bleeding during endoscopic intervention.

  4. Endovascular biopsy: Technical feasibility of novel endothelial cell harvesting devices assessed in a rabbit aneurysm model.

    Science.gov (United States)

    Cooke, Daniel L; Bauer, Diana; Sun, Zhengda; Stillson, Carol; Nelson, Jeffrey; Barry, David; Hetts, Steven W; Higashida, Randall T; Dowd, Christopher F; Halbach, Van V; Su, Hua; Saeed, Maythem M

    2015-02-01

    The lack of safe and reliable methods to sample vascular tissue in situ limits discovery of the underlying genetic and pathophysiological mechanisms of many vascular disorders, including aneurysms. We investigated the feasibility and comparable efficacy of in vivo vascular endothelial cell sampling using a spectrum of endovascular devices. Using the rabbit elastase carotid aneurysm model we evaluated the performance of existing aneurysmal coils, intracranial stents, and stent-like devices to collect vascular endothelial cells. Additionally, we modified a subset of devices to assess the effects of alterations to coil pitch, coil wire contour, and stent surface finishing. Device performance was evaluated by (1) the number of viable endothelial cells harvested, (2) the degree of vascular wall damage analyzed using digital subtraction angiography and histopathological analysis, and (3) the ease of device navigability and retrieval. Isolated cells underwent immunohistochemical analysis to confirm cell type and viability. Coil and stent specifications, technique, and endothelial cell counts were tabulated and statistical analysis performed. Using conventional detachable-type and modified aneurysm coils 11 of 14 (78.6%) harvested endothelial cells with a mean of 7.93 (±8.33) cells/coil, while 15 of 15 (100%) conventional stents, stent-like devices and modified stents harvested endothelial cells with a mean of 831.33 (±887.73) cells/device. Coil stiffness was significantly associated with endothelial cell count in univariate analysis (p = 0.044). For stents and stent-like devices univariate analysis demonstrated stent-to-aorta diameter ratios (p = 0.001), stent length (p = 0.049), and the use of a pulling retrieval technique (p = 0.019) significantly predictive of endothelial cell counts, though a multivariate model using these variables demonstrated only the stent-to-aorta diameter ratio (p = 0.029) predictive of endothelial cell counts. Modified

  5. Endovascular biopsy: Technical feasibility of novel endothelial cell harvesting devices assessed in a rabbit aneurysm model

    Science.gov (United States)

    Bauer, Diana; Sun, Zhengda; Stillson, Carol; Nelson, Jeffrey; Barry, David; Hetts, Steven W; Higashida, Randall T; Dowd, Christopher F; Halbach, Van V; Su, Hua; Saeed, Maythem M

    2015-01-01

    The lack of safe and reliable methods to sample vascular tissue in situ limits discovery of the underlying genetic and pathophysiological mechanisms of many vascular disorders, including aneurysms. We investigated the feasibility and comparable efficacy of in vivo vascular endothelial cell sampling using a spectrum of endovascular devices. Using the rabbit elastase carotid aneurysm model we evaluated the performance of existing aneurysmal coils, intracranial stents, and stent-like devices to collect vascular endothelial cells. Additionally, we modified a subset of devices to assess the effects of alterations to coil pitch, coil wire contour, and stent surface finishing. Device performance was evaluated by (1) the number of viable endothelial cells harvested, (2) the degree of vascular wall damage analyzed using digital subtraction angiography and histopathological analysis, and (3) the ease of device navigability and retrieval. Isolated cells underwent immunohistochemical analysis to confirm cell type and viability. Coil and stent specifications, technique, and endothelial cell counts were tabulated and statistical analysis performed. Using conventional detachable-type and modified aneurysm coils 11 of 14 (78.6%) harvested endothelial cells with a mean of 7.93 (±8.33) cells/coil, while 15 of 15 (100%) conventional stents, stent-like devices and modified stents harvested endothelial cells with a mean of 831.33 (±887.73) cells/device. Coil stiffness was significantly associated with endothelial cell count in univariate analysis (p = 0.044). For stents and stent-like devices univariate analysis demonstrated stent-to-aorta diameter ratios (p = 0.001), stent length (p = 0.049), and the use of a pulling retrieval technique (p = 0.019) significantly predictive of endothelial cell counts, though a multivariate model using these variables demonstrated only the stent-to-aorta diameter ratio (p = 0.029) predictive of endothelial cell counts. Modified

  6. Online tracking of interventional devices for endovascular aortic repair.

    Science.gov (United States)

    Volpi, Daniele; Sarhan, Mhd H; Ghotbi, Reza; Navab, Nassir; Mateus, Diana; Demirci, Stefanie

    2015-06-01

    The continuous integration of innovative imaging modalities into conventional vascular surgery rooms has led to an urgent need for computer assistance solutions that support the smooth integration of imaging within the surgical workflow. In particular, endovascular interventions performed under 2D fluoroscopic or angiographic imaging only, require reliable and fast navigation support for complex treatment procedures such as endovascular aortic repair. Despite the vast variety of image-based guide wire and catheter tracking methods, an adoption of these for detecting and tracking the stent graft delivery device is not possible due to its special geometry and intensity appearance. In this paper, we present, for the first time, the automatic detection and tracking of the stent graft delivery device in 2D fluoroscopic sequences on the fly. The proposed approach is based on the robust principal component analysis and extends the conventional batch processing towards an online tracking system that is able to detect and track medical devices on the fly. The proposed method has been tested on interventional sequences of four different clinical cases. In the lack of publicly available ground truth data, we have further initiated a crowd sourcing strategy that has resulted in 200 annotations by unexperienced users, 120 of which were used to establish a ground truth dataset for quantitatively evaluating our algorithm. In addition, we have performed a user study amongst our clinical partners for qualitative evaluation of the results. Although we calculated an average error in the range of nine pixels, the fact that our tracking method functions on the fly and is able to detect stent grafts in all unfolding stages without fine-tuning of parameters has convinced our clinical partners and they all agreed on the very high clinical relevance of our method.

  7. Drug delivering technology for endovascular management of infrainguinal peripheral artery disease.

    Science.gov (United States)

    Sarode, Karan; Spelber, David A; Bhatt, Deepak L; Mohammad, Atif; Prasad, Anand; Brilakis, Emmanouil S; Banerjee, Subhash

    2014-08-01

    Endovascular intervention has become a well-recognized treatment modality for peripheral artery disease; however, mid- and long-term outcomes have been plagued by limited durability. Plain balloon angioplasty and bare-metal stents have historically suffered from high restenosis rates leading to the need for frequent repeat revascularization procedures. The innovation of locally administered, drug-delivering balloons and stents has been a direct result of technological innovations directed toward prevention and treatment of this limitation. Over the last 5 years, numerous clinical trials investigating the use of drug-coated stents and drug-coated balloons indicate a significant improvement in endovascular treatment durability and outcomes. This review provides an up-to-date assessment of the current evidence for the use of drug-coated stents and drug-coated balloons in the treatment of femoropopliteal and infrapopliteal peripheral artery disease. Additionally, it provides an overview of the development of this technology, highlights landmark ongoing and completed clinical trials, examines evidence to support the use of drug-coated technologies in combination with other modalities, and examines promising new technological developments. Last, it summarizes the challenges and safety concerns that have delayed U.S. Food and Drug Administration approval of these devices.

  8. Modeling and visualization techniques for virtual stenting of aneurysms and stenoses.

    Science.gov (United States)

    Egger, Jan; Grosskopf, Stefan; Nimsky, Christopher; Kapur, Tina; Freisleben, Bernd

    2012-04-01

    In this work, we present modeling and visualization techniques for virtual stenting of aneurysms and stenoses. In particular, contributions to support the computer-aided treatment of artery diseases - artery enlargement (aneurysm) and artery contraction (stenosis) - are made. If an intervention takes place, there are two different treatment alternatives for this kind of artery diseases: open surgery and minimally invasive (endovascular) treatment. Computer-assisted optimization of endovascular treatments is the main focus of our work. In addition to stent simulation techniques, we also present a computer-aided simulation of endoluminal catheters to support the therapy-planning phase. The stent simulation is based on a three-dimensional Active Contour Method and is applicable to both non-bifurcated (I-stents) and bifurcated stents (Y-stents). All methods are introduced in detail and are evaluated with phantom datasets as well as with real patient data from the clinical routine. Additionally, the clinical prototype that is based upon these methods is described.

  9. Prophylactic endovascular management of peripheral artery disease in elderly candidates prior to cardiac surgery

    Institute of Scientific and Technical Information of China (English)

    Gianluca Rigatelli; Paolo Cardaioli; Massimo Giordan; Loris Roncon; Emiliano Bedendo; Tranquillo Milan; Giorgio Rigatelli

    2006-01-01

    Background and objectives Peripheral vascular disease (PVD) is a major risk factor in candidates for cardiac surgery and can impact morbidity and mortality in the perioperative and follow-up period. Elderly patients with PVD may benefit from endovascular treatment prior to cardiac surgery. We sought to assess the common clinical settings requiring prophylactic endovascular treatment before coronary surgery in elderly patients, the results, and the mid-term impact on subsequent revascularization. Methods Between November 2002 and June 2006, 37 patients (25 males, mean age 79.9±8.3 years, mean serum creatinine 1.9±0.6 mg/dl) underwent endovascular repair of PVD before cardiac surgery. For each patient, diagnostic methods, indications for intervention, types of interventions, procedural success, and complications were recorded. Results Four clinical settings were identified: renal artery stenting prior to coronary surgery (7 patients), iliac artery angioplasty and stenting (10 patients) in order to facilitate aortic balloon pump insertion after surgery, subclavian artery angioplasty and stenting prior to utilization of ipsilateral arterial conduits bypass surgery (5patients), and carotid artery stenting before coronary surgery (15 patients). Technical success was achieved in all patients (100%);complications included brachial artery occlusion (1 patient), minor stroke (2 patients), contrast nephropathy (1 patient), and minor bleeding at the puncture site (3 patients). All patients underwent successful coronary or valvular surgery; no patients died in the perioperative period. After a mean follow-up of 26.6±3.1 months, all patients are alive and free from anginal symptoms or valvular dysfunction without clinical or Doppler ultrasonography evidence of restenosis of the implanted peripheral vascular stents. Conclusions It is not unusual for elderly patients who are candidates for cardiac surgery to require endovascular intervention for significant PVD prior to

  10. [Late complication of surgical repair of aortic coarctation: ruptured pseudoaneurysm of the aorta treated by thoracic endovascular aortic repair].

    Science.gov (United States)

    Varejka, P; Lubanda, J C; Prochazka, P; Heller, S; Beran, S; Dostal, O; Charvat, F; Horejs, J; Semrad, M; Linhart, A

    2010-06-01

    Aortic coarctation is a frequent congenital defect requiring early surgical treatment. Late complications of these surgical procedures can be fatal as in the case of a ruptured anastomotic pseudoaneurysm. We present a case of a 49-year-old man presenting with hemorrhagic shock due to this complication who was successfully treated by endovascular techniques with implantation of two stent grafts. This case illustrates the fact that endovascular aortic repair is feasible, certainly less invasive and very efficient for this type of complication when used in an experienced center.

  11. Tratamiento endovascular de estenosis carotidea sin empleo de sistemas de protección. Estudio descriptivo, complicaciones y seguimiento

    OpenAIRE

    Jiménez Gómez, Elvira

    2014-01-01

    1.- INTRODUCCIÓN: Una de las causas más frecuente de eventos cerebrovasculares es la estenosis de carótida. Su tratamiento disminuye de manera significativa el riesgo de accidentes cerebrovasculares. La estenosis de carótida puede tratarse mediante cirugía o mediante técnicas endovasculares con colocación de un stent. Inicialmente el tratamiento de elección de la estenosis de carótida era la endarterectomía quirúrgica, sin embargo, hoy en día los tratamientos endovasculares ...

  12. Endovascular treatment of unruptured posterior circulation intracranial aneurysms

    Directory of Open Access Journals (Sweden)

    Xianli Lv

    2016-01-01

    Full Text Available Background and Purpose: Endovascular treatment of unruptured posterior circulation intracranial aneurysms (UPCIAs is limited in the International Study of Unruptured Intracranial Aneurysms (ISUIA. The aim of this study is to evaluate the periprocedural morbidity, mortality, and midterm clinical and angiographic follow-ups of endovascular treatment of UPCIAs. Materials and Methods: Retrospective analysis of all patients treated in a 2-year period (89 patients: 10-78 years of age, mean: 45.5 ± 14.3/92 UPCIAs. Fifty-eight aneurysms were found incidentally, 12 in association with mass effect symptoms and 22 with stroke. Results: A clinical improvement or stable outcome was achieved in 84 patients (94.4%. The two cases of permanent morbidity included a patient with paralysis and another patient with hemianopia. One patient died after treatment of a giant fusiform vertebrobasilar aneurysm. In one patient, the aneurysm ruptured during treatment, resulting in death. Another patient suffered a fatal aneurysm rupture 4 days after treatment. Giant size (P = 0.005 and mass effect presentation (P = 0.029 were independent predictors of unfavorable outcomes in UPCIAs. Angiographic follow-up was available in 76 of the 86 surviving patients (88.4% with a mean of 6.8 months (range: 1-36 months. Recanalization in six patients (7.9% at 3 months, 4 months, 4 months, 24 months, and 36 months required retreatment in three patients. In-stent stenosis of >50% was found in three patients. Conclusion: Endovascular therapy is an attractive option for UPCIAs with stable midterm outcome. However, the current endovascular option seems to have a limitation for the treatment of the aneurysm with giant size or mass effect presentation.

  13. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenbruch, Georg, E-mail: gmuehlenbruch@ukaachen.de; Nikoubashman, Omid; Steffen, Bjoern; Dadak, Mete [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany); Palmowski, Moritz [RWTH Aachen University, Department of Nuclear Medicine, University Hospital (Germany); Wiesmann, Martin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany)

    2013-02-15

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  14. Stent tunnel technique to save thrombosed native hemodialysis fistula with extensive venous aneurysm

    Directory of Open Access Journals (Sweden)

    Rabellino M

    2017-07-01

    Full Text Available Martin Rabellino,1 Guillermo J Rosa-Diez,2 Sergio A Shinzato,1 Pablo Rodriguez,1 Oscar A Peralta,1 Maria S Crucelegui,2 Rosario Luxardo,2 Agustina Heredia-Martinez,2 Mariela I Bedini-Rocca,2 Ricardo D García-Mónaco1 1Department of Angiography and Endovascular Therapy, 2Department of Nephrology, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina Introduction and purpose: The increasing number of patients undergoing hemodialysis and the limited number of access sites have resulted in an increasing number of techniques to maintain vascular access for hemodialysis. Thrombosed arteriovenous (AV fistulas with large venous aneurysms have poor treatment results, with both endovascular and surgical techniques, leading to a high rate of definitive AV access loss. The purpose of this study was to review the feasibility and initial results of this novel endovascular treatment of thrombosed AV fistulas with large venous aneurysms.Materials and methods: A novel endovascular treatment technique of inserting nitinol auto-expandable uncovered stents stretching through the whole puncture site area, thus creating a tunnel inside the thrombus, was retrospectively analyzed and described.Results: A total of 17 stents were placed in 10 hemodialysis fistulas, with a mean venous coverage length of 17.8 cm. In all the cases, 100% technical success was achieved, with complete restoration of blood flow in all patients. There were no procedure-related complications. The mean follow-up was 167 days (range 60–420 days, with a primary and assisted patency of 80% and 100%, respectively. No multiple trans-stent struts-related complications were observed. Three stent fractures were diagnosed with plain films at the site of puncture without consequence in the venous access permeability.Conclusion: The “stent tunnel technique” is a feasible, safe and effective alternative to salvage native hemodialysis access, thus extending the function of the venous access with

  15. Intravascular ultrasound in the endovascular management of atherosclerotic peripheral occlusive disease.

    Science.gov (United States)

    Colli, Rosa; Di Stasi, Carmine; Modugno, Pietro; Orlando, Giuseppe; Cavallaro, Antonio

    2004-01-01

    This study is a retrospective analysis of the impact of intravascular ultrasound in addiction to conventional angiography in 36 patients with 55 stenotic peripheral arterial lesions treated with angioplasty and/or stenting. Before treatment, intravascular ultrasound imaging showed that the vessel diameter was underestimated with angiography in 6 cases. The correlation index between angiography and intravascular ultrasound measurements, however, was significant in 27 arterial lesions. After endovascular treatment, angiography showed 3 vessel dissections and no incomplete stent deployment, whereas intravascular ultrasound showed 15 dissections and 5 instances of stent underdeployment. If we consider the intravascular ultrasound data as the gold standard, the specificity of angiography is 100%, while its sensitivity is 56% for vessel dissection and 75% for stent deployment. In the follow up of the 16 patients treated for iliac lesions with intravascular ultrasound control, re-stenosis occurred in 5% (primary patency 94.7%); in a control group of 15 patients treated in the same period without intravascular ultrasound control, re-stenosis occurred in 15.8% (primary patency 83.4%, difference not statistically significant). In conclusion, in the peripheral arteries intravascular ultrasound is more accurate than arteriography in evaluating dissection and stent deployment, but the routine use of intravascular ultrasound in every case of iliac PTA or stenting would not appear justified.

  16. Balloon Tamponade Treatment of a Stent-graft Related Rupture with a Splenic Artery Pseudoaneurysm: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, See Hyung; Kim, Young Hwan [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    An arterial rupture resulting from stent-graft placement of a splenic artery pseudoaneurysm is a life-threatening complication and immediate endovascular or surgical treatment is indicated. We report a case of a stentgraft related splenic artery rupture treated solely with a prolonged balloon catheter tamponade, which resulted in preservation of vessel patency

  17. Enterprise stent for waffle-cone stent-assisted coil embolization of large wide-necked arterial bifurcation aneurysms.

    Science.gov (United States)

    Padalino, David J; Singla, Amit; Jacobsen, Walter; Deshaies, Eric M

    2013-01-01

    Large wide-necked arterial bifurcation aneurysms present a unique challenge for endovascular coil embolization treatment. One technique described in the literature deploys a Neuroform stent into the neck of the aneurysm in the shape of a waffle-cone, thereby acting as a scaffold for the coil mass. This case series presents four patients with large wide-necked bifurcation aneurysms treated with the closed-cell Enterprise stent using the waffle-cone technique. Four patients (59 ± 18 years of age) with large wide-necked arterial bifurcation aneurysms (three basilar apex and one MCA bifurcation) were treated with the waffle-cone technique using the Enterprise stent as a supporting device for stent-assisted coil embolization. Three of the patients presented with aneurysmal subarachnoid hemorrhage (Hunt-Hess 2-3; Fisher Grade 3-4). There was no procedural morbidity or mortality associated with treatment itself. One aneurysm was completely obliterated, and three had small residual necks. One patient developed an area of PCA infarct and visual field cut one month after the procedure and required recoiling of the residual neck. The flared ends of the Enterprise stent remodeled the aneurysm neck by conforming to the shape of the neck without any technical difficulty, resulting in a stable scaffold holding the coils into the aneurysm. The closed cell construction, flexibility, and flared ends of the Enterprise stent allow it to conform to the waffle-cone configuration and provide a stable scaffold for coil embolization of large wide-necked arterial bifurcation aneurysms. We have had excellent initial results using the Enterprise stent with the waffle-cone technique. However, this technique is higher risk than standard treatment methods and therefore should be reserved for large wide-necked bifurcation aneurysms where Y stenting is needed, but not possible, and surgical clip ligation is not an option.

  18. Endovascular stroke treatment now and then-procedural and clinical effectiveness and safety of different mechanical thrombectomy techniques over time.

    Science.gov (United States)

    von Gadow, Niels; Nikoubashman, Omid; Freiherr, Jessica; Block, Frank; Reich, Arno; Fesl, Gunther; Wiesmann, Martin

    2017-02-01

    The most essential development in endovascular stroke treatment (EST) was the shift from intra-arterial thrombolysis to endovascular thrombectomy with dedicated thrombectomy devices, most notably the introduction of stent-retrievers. We evaluated procedural and clinical effectiveness and safety of different EST techniques over time. We retrospectively analyzed EST cases that were treated by the same interventionalist before (n=36) and after (n=50) stent-retrievers were established as the treatment device of first choice. EST techniques in the first cohort comprised intra-arterial thrombolysis (n=24), manual thrombus aspiration (n=15), the use of the Penumbra thrombectomy system (n=13) and the Phenox clot retriever (n=3), intracranial stenting (n=10), and EST with stent-retrievers as a salvage procedure (n=11). In the second cohort, EST with stent-retrievers was the treatment option of first choice (n=47). Intra-arterial thrombolysis (n=15) and stenting of the occluded vessel (n=1) were performed, whenever EST with stent-retrievers failed. In both cohorts, revascularization rates (TICI ≥2b) were high (91.7% and 86.0%, respectively). A significantly lower number of interventional techniques per case were required in the second cohort (mean ± SD, 1.4±0.5 vs. 2.1±0.9, P<0.001). Recanalization was achieved almost twice as fast in the second cohort (85 vs. 163 minutes on average, P<0.001). The rate of patients achieving good functional outcome (mRS ≤2) was higher in the second cohort (40.0% vs. 22.2%, P=0.083). Our findings imply that when stent-retrievers were established as first-line the treatment device a significantly lower number of interventional techniques per case were required and recanalization was achieved almost twice as fast.

  19. Effects of transcatheter closure of Fontan fenestration on exercise tolerance. kidecho@yahoo.com.

    Science.gov (United States)

    Momenah, Tarek S; Eltayb, Haifa; Oakley, Reida El; Qethamy, Howeida Al; Faraidi, Yahya Al

    2008-05-01

    Baffle fenestration is associated with a significantly better outcome in standard and high-risk patients undergoing completion of Fontan. We report the effects of subsequent transcatheter closure of fenestration on exercise capacity and oxygen saturation. Sixteen patients with a mean age of 10.3 years underwent Amplatzer septal occluder (ASO) device transcatheter closure of Fontan fenestration. All had a fenestrated Fontan operation 6 month to 8 years prior to the procedure. A stress test was performed before and after device closure of fenestration in 14 patients (2 patients did not tolerate stress test before the procedure). The fenestrations in all patients were successfully occluded with the use of the Amplatzer device occluder. No complications occurred during or after the procedure. O2 saturation increased from a mean 85.1 +/- 7.89% to 94.5 +/- 3.63% (p < 0.01) at rest and from 66.2 +/- 12.86% to 87.2 +/- 8.64% (p < 0.01) following exercise. Exercise duration has also increased from 8.22 +/- 2.74 min to 10.29 +/- 1.91 min (p < 0.05). Transcatheter closure of Fontan fenestration increases the duration of exercise capacity and increases O2 saturation at rest and after exercise.

  20. Neoatherosclerosis in the stent

    Directory of Open Access Journals (Sweden)

    A. A. Komkov

    2015-01-01

    Full Text Available Achievements of interventional cardiology in the treatment of coronary artery disease are based on coronary balloon angioplasty with implanting bare metal stents and drug eluting stents. Questions of complications such as early stent thrombosis and restenosis of stent were solved in a considerable degree. However, with the lengthening of the followup period, the problem of late complications became obvious. Except endothelization and fibromuscular proliferation in stented coronary arteries the process of plaque formation has an important influence on later complications in follow-up period more than one year. This process was defined as neoatherosclerosis. This is verified by clinical manifestations of the disease, histological studies, angioscopy, intravascular ultrasound and optical-coherence tomography in stented patients. Dynamic observation of the condition in stentedcoronary arteries showed multistep proliferation with restenosis, its regression, and neoatherosclerosis development. Evidences of neoatherosclerosis formation in stented coronary arteries are considered in this review.

  1. Pivotal results of the Medtronic Vascular Talent Thoracic Stent Graft System: the VALOR trial.

    Science.gov (United States)

    Fairman, Ronald M; Criado, Frank; Farber, Mark; Kwolek, Christopher; Mehta, Manish; White, Rodney; Lee, Anthony; Tuchek, J Michael

    2008-09-01

    This report summarizes the 30-day and 12-month results of endovascular treatment using the Medtronic Vascular Talent Thoracic Stent Graft System (Medtronic Vascular, Santa Rosa, Calif) for patients with thoracic aortic aneurysms (TAA) who are considered candidates for open surgical repair. The study was a prospective, nonrandomized, multicenter, pivotal trial conducted at 38 sites. Enrollment occurred between December 2003 and June 2005. Standard follow-up interval examinations were prescribed at 1 month, 6 months, 1 year, and annually thereafter. These endovascular results were compared with retrospective open surgical data from three centers of excellence. The Evaluation of the Medtronic Vascular Talent Thoracic Stent Graft System for the Treatment of Thoracic Aortic Aneurysms (VALOR) trial enrolled 195 patients, and 189 were identified as retrospective open surgical subjects. Compared with the open surgery group, the VALOR test group had similar age and sex distributions, but had a smaller TAA size. Patients received a mean number of 2.7 +/- 1.3 stent graft components. The diameters of 25% of the proximal stent graft components implanted were 40 mm. Left subclavian artery revascularization was performed before the initial stent graft procedure in 5.2% of patients. Iliac conduits were used in 21.1% of patients. In 33.5% of patients, the bare spring segment of the most proximally implanted device was in zones 1 or 2 of the aortic arch. In 194 patients (99.5%), vessel access and stent graft deployment were successful at the intended site. The 30-day VALOR results included perioperative mortality, 2.1%; major adverse advents, 41%; incidence of paraplegia, 1.5%; paraparesis, 7.2%; and stroke, 3.6%. The 12-month VALOR results included all-cause mortality, 16.1%; aneurysm-related mortality, 3.1%; conversion to open surgery, 0.5%; target aneurysm rupture, 0.5%; stent graft migration >10 mm, 3.9%; endoleak (12.2%), stent graft patency, 100%; stable or decreasing aneurysm

  2. Multimodal approach to endovascular treatment of visceral artery aneurysms and pseudoaneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lagana, Domenico [Vascular and Interventional Radiology, Department of Radiology, University of Insubria, Varese (Italy); Carrafiello, Gianpaolo [Vascular and Interventional Radiology, Department of Radiology, University of Insubria, Varese (Italy)]. E-mail: gcarraf@tin.it; Mangini, Monica [Vascular and Interventional Radiology, Department of Radiology, University of Insubria, Varese (Italy)]. E-mail: monica.mangini@tin.it; Dionigi, Gianlorenzo [Department of Surgery, University of Insubria, Varese (Italy); Caronno, Roberto [Vascular Surgery, University of Insubria, Varese (Italy); Castelli, Patrizio [Vascular Surgery, University of Insubria, Varese (Italy); Fugazzola, Carlo [Vascular and Interventional Radiology, Department of Radiology, University of Insubria, Varese (Italy)

    2006-07-15

    Purpose: To assess the feasibility and the effectiveness of endovascular treatment of visceral arteries aneurysms (VAAs) using a 'multimodal approach'. Material and methods: Twenty-five patients (mean age 60.1 years) with 29 VAAs (13 splenic, 4 hepatic, 3 gastroduodenal, 6 renal, 2 pancreatic-duodenal, 1 superior mesenteric) were considered suitable for endovascular treatment; 8/29 were ruptured. Saccular aneurysms (9/29) were treated by sac embolization with coils (in 4 cases associated with cyanoacrylate or thrombin) with preservation of artery patency. Fusiform aneurysms (6/29), were treated by an 'endovascular exclusion'. In 10/29 cases, supplied by a terminal branch, we performed an embolization of the afferent artery, with coils and cyanoacrylate or thrombin. 2/29 cases were treated with a stent-graft and 2/29 cases with a percutaneous ultrasound-guided thrombin injection and coils embolization of the afferent artery. The follow-up was performed by ultrasonography and/or CT-angiography 1 week after the procedure and then after 1, 6, and 12 months and thereafter annually. Results: In 29/29 cases we obtained an immediate exclusion. Two patient died for other reasons. Complication rate was 27.6% (7 spleen ischemia and 1 stent-graft occlusion). During the follow-up (range: 7 days-36 months, mean 18.7 months), we observed 3/29 (10.3%) cases of reperfusion in the first month, all treated successfully with a further endovascular procedure. Primary technical success was 89.7%; secondary technical success was 100%. Conclusion: Endovascular therapy can be considered a feasible and effective approach for VAAs with good primary and secondary success rates.

  3. Predictors for Symptomatic Intracranial Hemorrhage After Endovascular Treatment of Acute Ischemic Stroke.

    Science.gov (United States)

    Hao, Yonggang; Yang, Dong; Wang, Huaiming; Zi, Wenjie; Zhang, Meng; Geng, Yu; Zhou, Zhiming; Wang, Wei; Xu, Haowen; Tian, Xiguang; Lv, Penghua; Liu, Yuxiu; Xiong, Yunyun; Liu, Xinfeng; Xu, Gelin

    2017-05-01

    Symptomatic intracranial hemorrhage (SICH) pose a major safety concern for endovascular treatment of acute ischemic stroke. This study aimed to evaluate the risk and related factors of SICH after endovascular treatment in a real-world practice. Patients with stroke treated with stent-like retrievers for recanalizing a blocked artery in anterior circulation were enrolled from 21 stroke centers in China. Intracranial hemorrhage was classified as symptomatic and asymptomatic ones according to Heidelberg Bleeding Classification. Logistic regression was used to identify predictors for SICH. Of the 632 enrolled patients, 101 (16.0%) were diagnosed with SICH within 72 hours after endovascular treatment. Ninety-day mortality was higher in patients with SICH than in patients without SICH (65.3% versus 18.8%; P0.83 (odds ratio [OR], 2.07; 95% confidence interval [CI], 1.24-3.46), pretreatment Alberta Stroke Program Early Computed Tomography Score of stroke of cardioembolism type (OR, 1.91; 95% CI, 1.13-3.25), poor collateral circulation (OR, 1.97; 95% CI, 1.16-3.36), delay from symptoms onset to groin puncture >270 minutes (OR, 1.70; 95% CI, 1.03-2.80), >3 passes with retriever (OR, 2.55; 95% CI, 1.40-4.65) were associated with SICH after endovascular treatment. Incidence of SICH after thrombectomy is higher in Asian patients with acute ischemic stroke. Cardioembolic stroke, poor collateral circulation, delayed endovascular treatment, multiple passes with stent retriever device, lower pretreatment Alberta Stroke Program Early Computed Tomography Score, higher baseline neutrophil ratio may increase the risk of SICH. © 2017 American Heart Association, Inc.

  4. Fabrication of resorbable microporous intravascular stents for gene therapy applications.

    Science.gov (United States)

    Rajasubramanian, G; Meidell, R S; Landau, C; Dollar, M L; Holt, D B; Willard, J E; Prager, M D; Eberhart, R C

    1994-01-01

    The authors have produced resorbable, microporous endoluminal stents from Poly-L-lactic acid (PLLA)/Poly epsilon-caprolactone (PCL) blends. Both helical and tube stent designs have been obtained by solvent casting and flotation-precipitation fabrication techniques. A range of PLLA/PCL blend ratios and process variables were employed to investigate their influence on mechanical properties, porosity, and degradation rate. Polymer blends with higher PLLA proportions exhibit higher elastic moduli and ultimate tensile strength, and lower elongation, porosity, and degradation rates than do materials with higher PCL content. Stents with suitable mechanical properties for deployment and support of the vessel wall were obtained. Poly(ethylene oxide) was incorporated into these devices using an acid swelling technique, opening the pore structure and improving the hydrophilic character, thereby enabling the uptake of recombinant adenoviral vectors. The 50:50 PLLA/PCL blended stents were impregnated with recombinant adenovirus (AdCMB beta Gal, encoding a nuclear localizing variant of Escherichia coli beta-galactosidase). Cultured CV-1 cells incubated with stents impregnated with the recombinant virus expressed nuclear localized beta-galactosidase activity, confirming that absorbed virus is released from the matrix in an infectious form, with kinetics suggesting that genetically enhanced endovascular devices of this design are feasible.

  5. Role of interventional endovascular therapy for delayed hemorrhage after pancreaticoduodenectomy

    Institute of Scientific and Technical Information of China (English)

    WANG Zhi-jun; WANG Mao-qiang; LIU Feng-yong; DUAN Feng; SONG Peng; FAN Qing-sheng

    2010-01-01

    Background Delayed massive hemorrhage (DMH) after pancreaticoduodenectomy (PD) is a sedous complication and one of the most common causes of mortality after PD. Its ideal management remains unclear. This paper is to present our experience in the endovascular treatment of patients with DMH after PD using different techniques and materials.Methods During a seven years period, 19 patients (fifteen men, four women) with DMH arter PD were treated with endovascular procedures, including transcatheter arterial embolization (TAE) with coils embolization in eight cases, with coils plus N-butyl-2-cyanoacrylate (NBCA)-Lipiodol mixture in six cases, and stent-graft placement in five cases. The mean age of the patients was 58.2 years. Follow-up, including clinical condition, liver function tests, and Doppler ultrasound examinations, was documented.Results The immediate technical success rate was 84.2% (16/19). There were no significant procedure-related complications. Hemostasis was not achieved with interventional procedures in three patients: one died of uncontrolled bleeding four days after the second TAE, and two patients required emergency laparotomy without re-angiography because of worsening clinical status. Among the 16 patients with successfully stopped bleeding who became hemodynamically stable after the procedure without evidence of further bleeding, two patients died during the peri-interventional procedure period because of multiple organ failure, and fourteen patients survived to hospital discharge. The mean length of follow-up was 14.6 months. Recurrent bleeding after discharge did not occur in any of these cases. Clinical and laboratory follow-up findings were unremarkable. Doppler ultrasound examinatation verified patency of the hepatic artery in the four patients with stent-graft placement during the follow-up period (5 months-29 months; mean, 15.3 months).Conclusions Interventional endovascular procedure is a safe and technically feasible solution to control

  6. Use of a Bone Graft Drill Harvester to Create the Fenestration During Arthroscopic Ulnohumeral Arthroplasty.

    Science.gov (United States)

    Wijeratna, Malin D; Ek, Eugene T; Hoy, Gregory A; Chehata, Ash

    2015-10-01

    The Outerbridge-Kashiwagi procedure, or ulnohumeral arthroplasty, was described in 1978 as a method of treating elbow arthritis by creating a fenestration in the olecranon fossa. This fenestration diminishes the likelihood of recurrent spurs in the olecranon fossa and coronoid fossa, without loss of structural bony strength. Arthroscopic techniques have now been developed to perform this procedure. We describe an efficient method of creating the fenestration between the olecranon fossa and coronoid fossa during an arthroscopic ulnohumeral arthroplasty, or Outerbridge-Kashiwagi procedure, that also reduces the amount of residual bone debris produced during the resection.

  7. Long-term success of endovascular treatment of benign superior vena cava occlusion with chylothorax and chylopericardium

    Energy Technology Data Exchange (ETDEWEB)

    Veroux, Pierfrancesco; Veroux, Massimiliano; Bonanno, Maria Giovanna; Tumminelli, Maria Giuseppina [Department of Surgery and Transplantation, University Hospital, Via S. Sofia, 78, 95123 Catania (Italy); Baggio, Elda [Department of Surgery and Gastroenterological Sciences, University Hospital of Verona (Italy); Petrillo, Giuseppe [Department of Radiology, University Hospital, Via S. Sofia, 78, 95123 Catania (Italy)

    2002-07-01

    The most likely etiology of benign obstruction of the superior vena cava (SVC) include fibrosing mediastinitis and iatrogenic etiologies such as sclerosis and obstruction caused by pacemakers and central venous catheter. Percutaneous stenting of SVC has been used with success both in malignant and benign superior vena cava syndrome; however, long-term follow-up of endovascular procedures is not well known. We present a case of a patient with complete occlusion of SVC of benign etiology, presenting dramatically with bilateral chylothorax and chylopericardium with cardiac tamponade, who underwent successful vena caval revascularization with thrombolytic therapy and placement of self-expanding metallic stent. The 42-month follow-up could encourage endovascular procedures even in SVC syndrome of benign etiology. (orig.)

  8. A modified technique for Gore Excluder limb deployment in difficult iliac anatomy during endovascular abdominal aortic aneurysm repair.

    Science.gov (United States)

    Vourliotakis, George; Katsargyris, Αthanasios; Tielliu, Ignace F J; Zeebregts, Clark J; Verhoeven, Eric L G

    2015-02-01

    Complex iliac anatomy including extreme tortuosity constitutes a relative contraindication for endovascular abdominal aortic aneurysm repair with additional risk of limb-graft occlusion. The Gore Excluder limb-graft is a flexible stent-graft, which adapts easily to iliac tortuosity. Nevertheless, the presence of the stiff guide wire does not always allow for an ideal apposition of the stent graft to the angulated common iliac artery vessel wall. We describe herein a modified technique for Gore Excluder limb-graft deployment with partial removal of the stiff wire in cases with difficult tortuous or narrow iliac arteries during endovascular abdominal aortic aneurysm repair. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  9. Guided bone regeneration for fenestration defects in dental implants.

    Science.gov (United States)

    Yeh, Hwey-Chin; Hsu, Kuang-Wei

    2003-09-01

    Guided bone regeneration has been applied in implant dentistry for increasing the width and height of the alveolar ridge in areas with insufficient bone. Various materials and techniques have been used for this purpose. It refers to a surgical procedure by which utilizing a mechanical barrier to create a secluded space around the defect to permit bone regeneration without the competition of other tissues. This report presents a case with buccal fenestrations on maxillary implant sites observed during a surgical procedure. An allograft and a non-resorbable membrane were concomitantly used to increase the width of the alveolar ridge. Hard tissue regeneration was evident clinically. The implants were restored for functioning and followed for 2 years. Factors affecting outcomes are also discussed. Membrane stability and the space-making effect remain the keys to success.

  10. Vascular Response to Experimental Stent Malapposition and Under-Expansion.

    Science.gov (United States)

    O'Brien, Caroline C; Lopes, Augusto C; Kolandaivelu, Kumaran; Kunio, Mie; Brown, Jonathan; Kolachalama, Vijaya B; Conway, Claire; Bailey, Lynn; Markham, Peter; Costa, Marco; Ware, James; Edelman, Elazer R

    2016-07-01

    Up to 80% of all endovascular stents have malapposed struts, and while some impose catastrophic events others are inconsequential. Thirteen stents were implanted in coronary arteries of seven healthy Yorkshire pigs, using specially-designed cuffed balloons inducing controlled stent malapposition and under-expansion. Optical coherence tomography (OCT) imaging confirmed that 25% of struts were malapposed (strut-wall distance strut thickness) to variable extent (max. strut-wall distance malapposed group 0.51 ± 0.05 mm vs. apposed group 0.09 ± 0.05 mm, p = 2e-3). Imaging at follow-up revealed malapposition acutely resolved (struts remained malapposed at day 5), with strong correlation between lumen and the stent cross-sectional areas (slope = 0.86, p < 0.0001, R (2) = 0.94). OCT in three of the most significantly malapposed vessels at baseline showed high correlation of elastic lamina area and lumen area (R (2) = 0.96) suggesting all lumen loss was related to contraction of elastic lamina with negligible plaque/intimal hyperplasia growth. Simulation showed this vascular recoil could be partially explained by the non-uniform strain environment created from sub-optimal expansion of device and balloon, and the inability of stent support in the malapposed region to resist recoil. Malapposition as a result of stent under-expansion is resolved acutely in healthy normal arteries, suggesting existing animal models are limited in replicating clinically observed persistent stent malapposition.

  11. Modified fenestration with restorative spinoplasty for lumbar spinal stenosis.

    Science.gov (United States)

    Matsudaira, Ko; Yamazaki, Takashi; Seichi, Atsushi; Hoshi, Kazuto; Hara, Nobuhiro; Ogiwara, Satoshi; Terayama, Sei; Chikuda, Hirotaka; Takeshita, Katsushi; Nakamura, Kozo

    2009-06-01

    The authors developed an original procedure, modified fenestration with restorative spinoplasty (MFRS) for the treatment of lumbar spinal stenosis. The first step is to cut the spinous process in an L-shape, which is caudally reflected. This procedure allows easy access to the spinal canal, including lateral recesses, and makes it easy to perform a trumpet-style decompression of the nerve roots without violating the facet joints. After the decompression of neural tissues, the spinous process is anatomically restored (spinoplasty). The clinical outcomes at 2 years were evaluated using the Japanese Orthopaedic Association (JOA) scale and patients' satisfaction. Radiological follow-up included radiographs and CT. Between January 2000 and December 2002, 109 patients with neurogenic intermittent claudication with or without mild spondylolisthesis underwent MFRS. Of these, 101 were followed up for at least 2 years (follow-up rate 93%). The average score on the self-administered JOA scale in 89 patients without comorbidity causing gait disturbance improved from 13.3 preoperatively to 22.9 at 2 years' follow-up. Neurogenic intermittent claudication disappeared in all cases. The patients' assessment of treatment satisfaction was "satisfied" in 74 cases, "slightly satisfied" in 12, "slightly dissatisfied" in 2, and "dissatisfied" in 1 case. In 16 cases (18%), a minimum progression of slippage occurred, but no symptomatic instability or recurrent stenosis was observed. Computed tomography showed that the lateral part of the facet joints was well preserved, and the mean residual ratio was 80%. The MFRS technique produces an adequate and safe decompression of the spinal canal, even in patients with narrow and steep facet joints in whom conventional fenestration is technically demanding.

  12. Hepatic artery stent-grafts for the emergency treatment of acute bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Bellemann, Nadine, E-mail: nadine.bellemann@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Sommer, Christof-Matthias; Mokry, Theresa; Kortes, Nikolas; Gnutzmann, Daniel; Gockner, Theresa; Schmitz, Anne [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Weitz, Jürgen [Department of Surgery, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Department for Visceral, Thoracic and Vascular Surgery at the University Hospital, Technical University Dresden (Germany); Kauczor, Hans-Ulrich; Radeleff, Boris; Stampfl, Ulrike [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany)

    2014-10-15

    Highlights: • We report our experiences with stent-grafts for the treatment of acute hemorrhage from the hepatic artery or the stump of the gastroduodenal artery. • The technical success of stent-graft implantation was 88%. • The bleeding ceased immediately after stent-graft implantation in 88%. • The complication rate was 21%. - Abstract: Purpose: We evaluated the technical success and clinical efficacy of stent-graft implantation for the emergency management of acute hepatic artery bleeding. Methods: Between January 2010 and July 2013, 24 patients with hemorrhage from the hepatic artery were scheduled for emergency implantation of balloon expandable stent-grafts. The primary study endpoints were technical and clinical success, which were defined as successful stent-graft implantation with sealing of the bleeding site at the end of the procedure, and cessation of clinical signs of hemorrhage. The secondary study endpoints were complications during the procedure or at follow-up and 30-day mortality rate. Results: In 23 patients, hemorrhage occurred after surgery, and in one patient hemorrhage occurred after trauma. Eight patients had sentinel bleeding. In most patients (n = 16), one stent-graft was implanted. In six patients, two overlapping stent-grafts were implanted. The stent-grafts had a target diameter between 4 mm and 7 mm. Overall technical success was 88%. The bleeding ceased after stent-graft implantation in 21 patients (88%). The mean follow-up was 137 ± 383 days. In two patients, re-bleeding from the hepatic artery occurred during follow-up after 4 and 29 days, respectively, which could be successfully treated by endovascular therapy. The complication rate was 21% (minor complication rate 4%, major complication rate 17%). The 30-day mortality rate was 21%. Conclusions: Implantation of stent-grafts in the hepatic artery is an effective emergency therapy and has a good technical success rate for patients with acute arterial hemorrhage.

  13. An in vivo pilot study of a microporous thin film nitinol-covered stent to assess the effect of porosity and pore geometry on device interaction with the vessel wall.

    Science.gov (United States)

    Chun, Youngjae; Kealey, Colin P; Levi, Daniel S; Rigberg, David A; Chen, Yanfei; Tillman, Bryan W; Mohanchandra, K P; Shayan, Mahdis; Carman, Gregory P

    2017-03-01

    Sputter-deposited thin film nitinol constructs with various micropatterns were fabricated to evaluate their effect on the vessel wall in vivo when used as a covering for commercially available stents. Thin film nitinol constructs were used to cover stents and deployed in non-diseased swine arteries. Swine were sacrificed after approximately four weeks and the thin film nitinol-covered stents were removed for histopathologic evaluation. Histopathology revealed differences in neointimal thickness that correlated with the thin film nitinol micropattern. Devices covered with thin film nitinol with a lateral × vertical length = 20 × 40 µm diamond pattern had minimal neointimal growth with well-organized cell architecture and little evidence of ongoing inflammation. Devices covered with thin film nitinol with smaller fenestrations exhibited a relatively thick neointimal layer with inflammation and larger fenestrations showed migration of inflammatory and smooth muscle cells through the micro fenestrations. This "proof-of-concept" study suggests that there may be an ideal thin film nitinol porosity and pore geometry to encourage endothelialization and incorporation of the device into the vessel wall. Future work will be needed to determine the optimal pore size and geometry to minimize neointimal proliferation and in-stent stenosis.

  14. Fenestration of the superior medullary velum as treatment for a trapped fourth ventricle: a feasibility study.

    Science.gov (United States)

    Tubbs, R Shane; Wellons, John C; Salter, George; Oakes, W Jerry

    2004-03-01

    We developed a novel approach for fenestration of the trapped fourth ventricle utilizing the superior medullary velum (valve of Vieussens). Trapped fourth ventricles, which are seen often in the pediatric hydrocephalic population, are troublesome entities surgically. A right burr hole was carried out in 10 adult cadavers with no gross intracranial pathology and the superior medullary velum was fenestrated to the quadrigeminal cistern with the aid of an endoscope. This technique was carried out easily in all cadaveric specimens. With endoscopy, no vascular insult was appreciated either before or after fenestration of the superior medullary velum. These preliminary findings demonstrate that fenestration of the superior medullary velum may provide a good alternative to the present therapy of shunting trapped fourth ventricles, a therapy wrought with complications.

  15. Laser versus conventional fenestration in stapedotomy for otosclerosis: a systematic review

    NARCIS (Netherlands)

    Wegner, I.; Kamalski, D.M.A.; Tange, R.A.; Vincent, R.; Stegeman, I.; van der Heijden, G.J.M.; Grolman, W.

    2014-01-01

    Objectives/Hypothesis To assess hearing results and complications following primary stapedotomy in otosclerosis patients comparing the use of laser and conventional techniques for fenestration. Study Design Systematic literature review. Methods A systematic bibliographic search was conducted in

  16. Assessment of Competence in EVAR Stent Graft Sizing and Selection.

    Science.gov (United States)

    Strøm, M; Lönn, L; Bech, B; Schroeder, T V; Konge, L

    2017-06-01

    The aims of this study were to develop a test of competence in endovascular aortic repair (EVAR) stent graft sizing and selection; to examine the test for evidence of validity; and to explore the experience required for the task. The test was developed based on a literature review resulting in 22 anatomical assessment points and a graft selection. Validity evidence was explored in an international cross sectional study. Twenty-two consultants with varying levels of experience in the field (novices, intermediates, and experts) were presented with computed tomography angiography of the aortic vessels from three patients. Test scores were based on summed z-scores using the anatomical measurements and graft choices of the experts as a reference. A proficiency score was established using the contrasting groups standard setting method. The assessment was shown to be reliable with an intraclass correlation coefficient of 0.83 (p<.001) and high internal consistency with a Cronbach's α of .91 (p<.001). Mann-Whitney U test showed that experts performed significantly better than novices and intermediates (p<.002 and p<.005, respectively). Regarding anatomical measurements, Mann-Whitney U test could discriminate between experts and novices (p=.002), between experts and intermediates (p=.010), and between novices and intermediates (p=.036). In stent selection the experts performed significantly better than both the novices and the intermediates (p=.002 and p=.007, respectively), while there was no significant difference between the two non-expert groups (p=1). A credible passing standard with appropriate consequences was established using the contrasting groups methods. This study presents a standardised and objective assessment tool of competence in vessel analysis and stent graft selection for endovascular aortic repair. This was supported by strong validity evidence with good internal consistency and discriminatory ability. The tool may be used to facilitate training and

  17. Auxetic coronary stent endoprosthesis

    DEFF Research Database (Denmark)

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar;

    2014-01-01

    BACKGROUND: Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit...... a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable...... for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. METHODS: The auxetic design...

  18. Short-term results of carotid stenting for the treatment of extracranial carotid occlusive disease

    Institute of Scientific and Technical Information of China (English)

    FU Wei-guo; ZHU Ting; CHEN Bin; JIANG Jun-hao; YANG Jue; SHI Zhen-yu

    2006-01-01

    @@ Carotid artery angioplasty and stenting (CAS) has been performed with increasing frequency for the treatment of extracranial carotid occlusive diseases (ECOD) in recent years. Its feasibility and safety are supported by the Stenting and Angioplasty with Protection in Patient at High Risk for Endarterectomy (SAPPHIRE) trial,1 which revealed a lower incidence of death, stroke and myocardial infarction compared with carotid endarterectomy (CEA) in high-risk patients. However, it is a pity that up to now, initial results of this endovascular procedure have yet been infrequently documented in China. This retrospective study was to analyze the short-term results of CAS to treat ECOD in a single medical center.

  19. Excellent long-term results with iliac stenting in local anesthesia for post-thrombotic syndrome

    DEFF Research Database (Denmark)

    Klitfod, Lotte; Just, Sven; Foegh, Pia

    2015-01-01

    BACKGROUND: Only 20% of iliac veins will recanalize on anticoagulation (AC) treatment alone and may, therefore, develop venous obstruction after iliofemoral deep venous thrombosis (DVT). A considerable number of these patients will suffer from post-thrombotic syndrome (PTS) leading to impaired qu...... stent was 89% (17/19) and 16 patients (84 %) had almost or total symptom relief at follow-up. CONCLUSION: Endovascular stenting of iliac obstruction in local anesthesia is minimally invasive and shows excellent long-term outcomes for patients suffering from PTS....

  20. Stent graft repair of iatrogenic femoral arteriovenous fistula: a useful therapeutic approach in a hostile groin.

    Science.gov (United States)

    De Martino, Randall R; Nolan, Brian W; Powell, Richard J; Walsh, Daniel B; Stone, David H

    2010-01-01

    The incidence of iatrogenic femoral arteriovenous fistulas (IFAVF) has increased in contemporary practice. We herein report the case of a 55-year-old obese woman with significant surgical comorbidities who sustained an IFAVF between the superficial femoral artery (SFA) and the femoral vein. Given her substantial risk factors, she was treated with a SFA stent-graft (iCast 6 x 22 mm) using a contralateral endovascular approach. She remains asymptomatic at 15 months with ongoing resolution of the AVF. This report highlights the utility of stent-graft repair of an IFAVF in high surgical risk patients or in those with ''hostile'' anatomy.

  1. Thrombus Volume Change Visualization after Endovascular Abdominal Aortic Aneurysm Repair

    Science.gov (United States)

    Maiora, Josu; García, Guillermo; Macía, Iván; Legarreta, Jon Haitz; Boto, Fernando; Paloc, Céline; Graña, Manuel; Abuín, Javier Sanchez

    A surgical technique currently used in the treatment of Abdominal Aortic Aneurysms (AAA) is the Endovascular Aneurysm Repair (EVAR). This minimally invasive procedure involves inserting a prosthesis in the aortic vessel that excludes the aneurysm from the bloodstream. The stent, once in place acts as a false lumen for the blood current to travel down, and not into the surrounding aneurysm sac. This procedure, therefore, immediately takes the pressure off the aneurysm, which thromboses itself after some time. Nevertheless, in a long term perspective, different complications such as prosthesis displacement or bloodstream leaks into or from the aneurysmatic bulge (endoleaks) could appear causing a pressure elevation and, as a result, increasing the danger of rupture. The purpose of this work is to explore the application of image registration techniques to the visual detection of changes in the thrombus in order to assess the evolution of the aneurysm. Prior to registration, both the lumen and the thrombus are segmented

  2. Tratamento endovascular de lesões arteriais traumáticas Endovascular management of traumatic arterial injuries

    Directory of Open Access Journals (Sweden)

    Ruy Fernandes e Fernandes

    2011-03-01

    Full Text Available Introdução: As lesões arteriais traumáticas ocorrem em menos de 10% de politraumatizados e, nos países desenvolvidos, tem-se observado uma preponderância crescente de traumatismos vasculares iatrogénicos. Recentemente vários autores têm descrito a utilização de técnicas endovasculares com sucesso, pelo menor risco cirúrgico, em lesões de difícil acesso cujo tratamento convencional requer grande exposição cirúrgica, dificuldade técnica e mortalidade ou morbilidade apreciáveis. Os procedimentos endovasculares representam ainda uma alternativa terapêutica com menor mortalidade no tratamento de complicações crónicas de traumatismos vasculares, nomeadamente nos aneurismas pós-traumáticos do istmo aórtico (APTIA. Os autores apresentam uma série de doentes com lesões traumáticas arteriais diversas, em fase aguda ou crónica, tratados por via endovascular. Casos Clínicos: Sete doentes (21-77 anos, foram submetidos a tratamento endovascular de traumatismos vasculares na fase aguda ou crónica. Quatro doentes apresentavam lesões traumáticas agudas: 1 caso de rotura traumática do istmo aórtico (RTIA em politraumatismo por acidente de viação; 1 caso de rotura da artéria subclávia (RAS iatrogénica após tentativa de colocação de catéter de hemodiálise; 1 caso rotura de artéria renal (RAR durante angioplastia/stent por doença renovascular; 1 caso de fístula arterio-venosa (FAV da artéria renal intra-parenquimatosa iatrogénica após tumorectomia laparoscópica. Três doentes com complicações crónicas de traumatismos torácicos apresentavam falsos aneurismas do arco aórtico. Os doentes com roturas arteriais foram submetidos a exclusão endovascular com endoprótese e o doente com FAV renal foi submetido a embolização com coils. Os três doentes portadores de APTIA foram submetidos a: tratamento endovascular de aneurisma da aorta torácica (TEVAR-1; “debranching” com bypass carótido-subclávio e TEVAR-2

  3. Tissue Responses to Stent Grafts with Endo-Exo-Skeleton for Saccular Abdominal Aortic Aneurysms in a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Il Young; Chung, Jin Wook; Kim, Hyo Cheol [Dept. of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul (Korea, Republic of); Choi, Young Ho; So Young Ho [Dept. of Radiology, Seoul National University Boramae Hospital, Seoul (Korea, Republic of); Kim, Hyun Beom [Dept. of Radiology, National Cancer Center, Goyang (Korea, Republic of); Min, Seung Kee [Dept. of Surgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2014-10-15

    We evaluated the effect of close contact between the stent and the graft on the induction of endothelial covering on the stent graft placed over an aneurysm. Saccular abdominal aortic aneurysms were made with Dacron patch in eight dogs. The stent graft consisted of an inner stent, a expanded polytetrafluoroethylene graft, and an outer stent. After sacrificing the animals, the aortas with an embedded stent graft were excised. The aortas were inspected grossly and evaluated microscopically. The animals were sacrificed at two (n = 3), six (n = 3), and eight months (n = 2) after endovascular repair. In two dogs, the aortic lumen was occluded at two months after the placement. On gross inspection of specimens from the other six dogs with a patent aortic lumen, stent grafts placed over the normal aortic wall were covered by glossy white neointima, whereas, stent grafts placed over the aneurysmal aortic wall were covered by brownish neointima. On microscopic inspection, stent grafts placed over the normal aortic wall were covered by thin neointima (0.27 ± 0.05 mm, mean ± standard deviation) with an endothelial layer, and stent grafts placed over the aneurysmal aortic wall were covered by thick neointima (0.62 ± 0.17 mm) without any endothelial lining. Transgraft cell migration at the normal aortic wall was more active than that at the aneurysmal aortic wall. Close contact between the stent and the graft, which was achieved with stent grafts with endo-exo-skeleton, could not enhance endothelial covering on the stent graft placed over the aneurysms.

  4. Leakage Characteristics of Dual-Cannula Fenestrated Tracheostomy Tubes during Positive Pressure Ventilation: A Bench Study

    OpenAIRE

    Thomas Berlet; Mathias Marchon

    2016-01-01

    This study compared the leakage characteristics of different types of dual-cannula fenestrated tracheostomy tubes during positive pressure ventilation. Fenestrated Portex® Blue Line Ultra®, TRACOE® twist, or Rüsch® Traceofix® tracheostomy tubes equipped with nonfenestrated inner cannulas were tested in a tracheostomy-lung simulator. Transfenestration pressures and transfenestration leakage rates were measured during positive pressure ventilation. The impact of different ventilation modes, air...

  5. Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants.

    Directory of Open Access Journals (Sweden)

    Caroline C O'Brien

    Full Text Available Stacking cross-sectional intravascular images permits three-dimensional rendering of endovascular implants, yet introduces between-frame uncertainties that limit characterization of device placement and the hemodynamic microenvironment. In a porcine coronary stent model, we demonstrate enhanced OCT reconstruction with preservation of between-frame features through fusion with angiography and a priori knowledge of stent design.Strut positions were extracted from sequential OCT frames. Reconstruction with standard interpolation generated discontinuous stent structures. By computationally constraining interpolation to known stent skeletons fitted to 3D 'clouds' of OCT-Angio-derived struts, implant anatomy was resolved, accurately rendering features from implant diameter and curvature (n = 1 vessels, r2 = 0.91, 0.90, respectively to individual strut-wall configurations (average displacement error ~15 μm. This framework facilitated hemodynamic simulation (n = 1 vessel, showing the critical importance of accurate anatomic rendering in characterizing both quantitative and basic qualitative flow patterns. Discontinuities with standard approaches systematically introduced noise and bias, poorly capturing regional flow effects. In contrast, the enhanced method preserved multi-scale (local strut to regional stent flow interactions, demonstrating the impact of regional contexts in defining the hemodynamic consequence of local deployment errors.Fusion of planar angiography and knowledge of device design permits enhanced OCT image analysis of in situ tissue-device interactions. Given emerging interests in simulation-derived hemodynamic assessment as surrogate measures of biological risk, such fused modalities offer a new window into patient-specific implant environments.

  6. Cerebral foreign body reaction after carotid aneurysm stenting

    DEFF Research Database (Denmark)

    Lorentzen, Anastasia Orlova; Nome, Terje; Bakke, Søren Jacob

    2016-01-01

    Flow diverter stents are new important tools in the treatment of large, giant, or wide-necked aneurysms. Their delivery and positioning may be difficult due to vessel tortuosity. Common adverse events include intracranial hemorrhage and ischemic stroke, which usually occurs within the same day......, or the next few days after the procedure. We present a case where we encountered an unusual intracerebral complication several months after endovascular treatment of a large left internal carotid artery aneurysm, and where brain biopsy revealed foreign body reaction to hydrophilic polymer fragments distally...

  7. A suggested training programme for carotid artery stenting (CAS)

    Energy Technology Data Exchange (ETDEWEB)

    Gaines, Peter [Sheffield Vascular Institute, Northern General Hospital, Sheffield S5 7AU (United Kingdom)]. E-mail: P.A.gaines@Sheffield.ac.uk; Nicholson, Tony [Leeds Teaching Hospitals NHS Trust, Great George St., Leeds LS13EX (United Kingdom)]. E-mail: tonynick@tonynick.karoo.co.uk

    2006-10-15

    Carotid artery stenting as an alternative to traditional carotid endartrectomy is becoming increasingly important in the treatment of transient ischemic attack and stroke. Physicians from several different medical disciplines are interested in treating appropriate patients by this method. Patients are entitled to know what training and experience the surgeon or clinician has before giving consent. This should involve endovascular experience in all systems and experience and knowledge of cerebral angiography and intervention. A multidisciplinary approach and reporting of adverse events is vital for patient safety.

  8. Endovascular treatment paradigm of carotid blowout syndrome: Review of 8-years experience

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Wing Suet, E-mail: wws351@ha.org.hk [Department of Radiology, Tuen Mun Hospital, Tuen Mun (Hong Kong); Lai, Vincent, E-mail: vincentlai@hkcr.org [Department of Radiology, Tuen Mun Hospital, Tuen Mun (Hong Kong); Lau, Hin Yue, E-mail: lhy460@ha.org.hk [Department of Radiology, Tuen Mun Hospital, Tuen Mun (Hong Kong); Wong, Yiu Chung, E-mail: wongyc6@ha.org.hk [Department of Radiology, Tuen Mun Hospital, Tuen Mun (Hong Kong); Poon, Wai Lun, E-mail: poonwl@ha.org.hk [Department of Radiology, Tuen Mun Hospital, Tuen Mun (Hong Kong); Tan, Chong Boon, E-mail: tancb@ha.org.hk [Department of Radiology, Tuen Mun Hospital, Tuen Mun (Hong Kong)

    2013-01-15

    Objectives: Endovascular treatment is effective in treating carotid blowout syndrome (CBS). We reviewed our experience in addressing CBS over eight years and presented an account of the treatment paradigm and management algorithm. Method: All cases of CBS from 2003 to 2010 with endovascular treatment performed in our center were reviewed. 15 CBS in 14 patients were recruited. Based on our management algorithm, treatment regimen was stratified into deconstructive or constructive methods. Their clinical presentations, angiographic features, angiographic and clinical outcomes were reviewed. Results: 10 patients were treated with deconstructive method by means of permanent vessel occlusion (PVO) and 4 patients were treated with constructive method by means of placement of covered stent (n = 3) or flow diverting device (n = 1). Immediate hemostasis was achieved in all cases. 7 (50%) patients, in whom 5 treated with PVO and 2 with covered stent, had favorable outcomes and survived at a median follow-up period of 4 months (range: 1–84 months). Conclusion: Permanent vessel occlusion remains the gold standard of treatment and tends to show a favorable long-term outcome. Off-label use of covered stent and flow-diverting device can produce satisfactory results should balloon occlusion test fail, but long-term follow up would be required for definitive assessment.

  9. Endovascular treatment of recurrent intracranial aneurysms following previous microsurgical clipping with the Pipeline Embolization Device.

    Science.gov (United States)

    Ding, Dale; Starke, Robert M; Evans, Avery J; Jensen, Mary E; Liu, Kenneth C

    2014-07-01

    The treatment of intracranial aneurysms with microsurgical clipping is associated with a very low rate of recurrence. However, in cases of aneurysm recurrence after previous clipping, microsurgical dissection due to adhesions and fibrosis may be challenging, and it may be difficult to safely occlude the recurrent lesion without the risk of significant morbidity. Flow-diverting stents have drastically changed the landscape of endovascular neurosurgery. We present two patients with large, recurrent supraclinoid internal carotid artery (ICA) aneurysms which were previously clipped 17 and 23 years ago at outside institutions. Both recurrent lesions were treated with the Pipeline Embolization Device (PED; ev3 Endovascular, Irvine, CA, USA) without radiographic or clinical complications. In the first patient, the 15 mm aneurysm significantly decreased in size at 6 month angiographic follow-up. The 21 mm aneurysm in the second patient was completely occluded 7 months following PED treatment. The moderate degree of in-stent stenosis present on initial follow-up imaging resolved on angiography 11 months post-treatment. The management of recurrent aneurysms after clipping is sparsely reported in the literature due to its infrequent occurrence. In carefully selected cases, flow-diverting stents may be used for complex aneurysms of the distal ICA, even for those which have recurred following microsurgical clipping.

  10. Efficacy and Safety of Endovascular Intervention for the Management of Primary Entire-Inferior Vena Cava Occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qingqiao, E-mail: 1427286069@qq.com; Huang, Qianxin, E-mail: 18705206105@163.com; Shen, Bin, E-mail: 753021357@qq.com; Sun, Jingmin, E-mail: 383937658@qq.com; Wang, Xiaolong, E-mail: 781198238@qq.com; Liu, Hongtao, E-mail: hongtao6@vip.sina.com [The Affiliated Hospital of Xuzhou Medical College, Department of Interventional Radiology and Vascular Surgery (China)

    2015-06-15

    PurposeThis study was designed to investigate the safety and efficacy of endovascular intervention for the treatment of primary entire-inferior vena cava (IVC) occlusion.MethodsEndovascular interventions were performed in six patients for the treatment of primary entire-IVC occlusion. IVC and hepatic venography were performed via the jugular and femoral veins. Balloon angioplasty was used to revascularize the hepatic vein and IVC and a stent was placed in the IVC to maintain patency. Postoperative color Doppler ultrasonography was performed at 1, 3, 6, and 12 months, and then annually, to monitor the patency of the hepatic vein and IVC.ResultsThe IVC and one or two hepatic veins were successfully revascularized in five patients. Revascularization was successful in the right and left hepatic veins in one patient; however, IVC patency could not be established in this patient. Eleven Z-type, self-expanding stents were placed into the IVCs of five patients (three stents in two patients, two stents in two patients, and one stent in one patient). There were no instances of postoperative bleeding or mortality. Follow-up was conducted for 18–90 months (42.8 ± 26.5 months). None of the five patients suffered restenosis of the IVC or hepatic veins. However, there was one of the six cases of right hepatic vein restenosis at 18 months postprocedure that was revascularized after a second balloon dilatation.ConclusionsEndovascular intervention is safe and efficacious for the treatment of primary entire-IVC occlusion.

  11. Pivotal results for the Medtronic Valiant Thoracic Stent Graft System in the VALOR II trial.

    Science.gov (United States)

    Fairman, Ronald M; Tuchek, J Michael; Lee, W Anthony; Kasirajan, Karthikeshwar; White, Rodney; Mehta, Manish; Lyden, Sean; Mukherjee, Dipankar; Bavaria, Joseph

    2012-11-01

    We report 30-day and 12-month results of endovascular treatment with the Valiant Thoracic Stent Graft System (Medtronic Vascular, Santa Rosa, Calif) in patients with descending thoracic aortic aneurysms of degenerative etiology. The Valiant stent graft is an evolution of the Talent thoracic stent graft (Medtronic Vascular). The VALOR II (Evaluation of the Clinical Performance of the Valiant Thoracic Stent Graft System in the Treatment of Descending Thoracic Aneurysms of Degenerative Etiology in Subjects Who Are Candidates for Endovascular Repair) was a prospective, nonrandomized, pivotal trial conducted at 24 U.S. sites with enrollment between December 2006 and September 2009. Standard follow-up examinations, including physical examination, computed tomography, and chest radiography, were at 1, 6, and 12 months, and annually through 5 years. VALOR II outcomes were compared with those from the pivotal VALOR (Evaluation of the Medtronic Vascular Talent Thoracic Stent Graft System for the Treatment of Thoracic Aortic Aneurysms) trial of the Talent stent graft, which enrolled 195 patients with similar enrollment criteria. VALOR II enrolled 160 patients. Compared with VALOR patients, VALOR II patients had similar age and sex distribution but higher rates of cardiovascular risk factors and significantly more severe modified Society for Vascular Surgery/American Association for Vascular Surgery risk scores. Stent graft delivery and deployment were successful in 154 patients (96.3%). Outcomes at 30 days in VALOR II were perioperative mortality, 3.1%; major adverse events, 38.1%; paraplegia, 0.6%; paraparesis, 1.9%; and stroke, 2.5%. At 12 months, after the minimum sample size was reached, 151 patients were evaluated: aneurysm-related mortality was 4.0%, stent graft migration was 2.9%, and endoleak was 13.0%. Through 12 months, there were no ruptures, conversions to open surgery, secondary procedures due to endoleak >30 days, or loss of stent graft patency. The Valiant

  12. Are drug-eluting stents the future of SFA treatment?

    Science.gov (United States)

    Bosiers, M; Deloose, K; Keirse, K; Verbist, J; Peeters, P

    2010-02-01

    Drug-eluting stent (DES) technology was developed to prevent early thrombosis and late luminal loss to potentially improve long-term patency rates. Although favorable DES results have recently become available with the Zilver PTX and STRIDES studies, the high price of DES is a major drawback for this technology to become the golden standard for peripheral endovascular therapy in de novo femoro-popliteal (FP) lesions. Nevertheless, DES has the potential to make the difference and to establish itself as an important treatment option in patients presenting with TASC C&D FP lesions who are at high-risk for surgery and for the treatment of in-stent restenosis, where until now, no valuable treatment option has proven to be beneficial.

  13. Long-term results of endovascular therapy for proximal subclavian arterial obstructive lesions

    Institute of Scientific and Technical Information of China (English)

    WANG Ke-qin; LIAO Chuan-jun; ZHANG Yang; WANG Zhong-gao; YANG Bao-zhong; YUAN Chao; ZHANG Wang-de; YUAN Biao; XING Tong; SONG Sheng-han; LI Tan

    2010-01-01

    Background Endovascular therapy is a treatment option for localized occlusion of the subclavian artery. In this report the long-term experience with 59 patients is presented.Methods Between June 1998 and September 2008, we used endovascular therapy to treat 61 subclavian arterial obstructive lesions in 59 patients (46 males and 13 females, 34-82 years of age with a mean age (61.9±11.0) years). Twenty patients (34%) had clinical symptoms due to vertebrobasilar insufficiency, 26 (44%) had disabling arm ischemia, and 13 (22%) had both symptoms. We performed all procedures under local anesthesia. The approaches were from the femoral artery (n=47), brachial artery (n=\\, involving bilateral subclavian disease) or both (n=11). Sixty stents were implanted. All patients were followed-up at 1,3, 6, and 12 months post-procedure, and annually thereafter. Results We achieved technical success in 58 (95.1%) arteries, all of which were stented. There were three technical failures; two were due to the inability to cross over an occlusion, necessitating the switch to an axillo-axillary bypass, and the third was due to shock after digital subtraction angiography and prior to stenting. Arterial stenosis pre- and post-stenting was (83.6±10.8)% and (2.5±12.5)% (P <0.01). Clinical success was achieved in 55 of the 59 patients (93.4%). Of the four clinical failures, three were technical and the remaining patient had a stent thrombosis. Systolic blood pressure difference between the two brachial arteries was (44.7±18.5) vs. (2.2±3.9) mmHg (P <0.01). Primary patency was 98% at 12 months, 93% at 24 months, and 82% at 5 years. Five patients were lost to follow-up by 12 months post-stenting. Significant recurrent obstruction developed in five patients with resumption of clinical symptoms. The overall survival rate was 98.2% at 12 months, 89.5% at 24 months, and 84.5% at 5 years.Conclusions Endovascular therapy for proximal subclavian arterial obstructive lesions is effective and

  14. Endovascular Aortic Repair of Primary Adult Coarctation: Implications and Challenges for Postoperative Nursing.

    Science.gov (United States)

    Sheppard, Christina E; Then, Karen L; Rankin, James A; Appoo, Jehangir J

    2015-01-01

    Endovascular aortic repair is a relatively new surgical technique used to treat a variety of aortic pathologies. Aortic coarctation traditionally has been managed with open surgical repair, involving a large posterolateral thoracotomy, cardiopulmonary bypass, and replacement of the narrowed section of the aorta with a dacron graft. Recent advances in minimally invasive aortic surgery have allowed for repair of the diseased section with an endovascular stent placed percutaneously through the groin under intraoperative fluoroscopic guidance. In this paper, the authors willfocus on the implicationsfor postoperative nursing care after endovascular repair of aortic coarctation using a case study of a 17-year-old male. This novel technique required education of the health care team with respect to implications for practice, understanding potential complications, discharge planning and follow-up. With any new surgical technique there are many questions and challenges that health care professionals raise. The main concerns expressed from the health care team stemmed from a lack of understanding of the disease pathology, and the different risk profile associated with an endovascular repair in contrast to an open repair. The authors will address these concerns in detail.

  15. Cardiovascular and Interventional Radiological Society of Europe Guidelines on Endovascular Treatment in Aortoiliac Arterial Disease

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Michele, E-mail: michele.rossi@uniroma1.it [Sant’Andrea University Hospital, Interventional Radiology Unit (Italy); Iezzi, Roberto, E-mail: roberto.iezzi.md@gmail.com [“Sacro Cuore” Catholic University, Radiology Department (Italy)

    2013-11-06

    PurposeThese guidelines are intended for use in assessing the standard for technical success and safety in aorto-iliac percutaneous endovascular interventions.MethodsAny recommendation contained in the text comes from the highest level and extension of literature review available to date.ResultsThe success of endovascular procedures is strictly related to an accurate planning based mainly on CT- or MR-angiography. TASC II A through C lesions have an endovascular-first option Pre-procedure ASA antiplatelet therapy is advisable in all cases. The application of stents improves the immediate hemodynamic and most likely long-term clinical results. Cumulative mean complication rate is 7.51 % according to the most relevant literature. Most of the complications can be managed by means of percutaneous techniques.ConclusionThe design and quality of devices, as well as the easy and accuracy of performing these procedures, have improved over the last decades, leading to the preferential treatment of aorto-iliac steno-obstructive disease via endovascular means, often as first-line therapy, with high technical success rate and low morbidity. This is mirrored by the decreasing number of patients undergoing surgical grafts over the last years with patency, limb salvage, and survival rates equivalent to open reconstruction.

  16. MRI assessment of thoracic stent grafts after emergency implantation in multi trauma patients: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Rasche, Volker [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); University Hospital Ulm, University of Ulm, Department of Internal Medicine II, Ulm (Germany); Oberhuber, Alexander; Orend, Karl-Heinz [University Hospital Ulm, Department of Vascular and Thoracic Surgery, Ulm (Germany); Trumpp, Stephan [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); University Hospital Ulm, Department of Vascular and Thoracic Surgery, Ulm (Germany); Bornstedt, Axel; Merkle, Nico; Rottbauer, Wolfgang [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); Hoffmann, Martin [University Hospital Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany)

    2011-07-15

    To evaluate the feasibility of MRI for static and dynamic assessment of the deployment of thoracic aortic stent grafts after emergency implantation in trauma patients. Twenty patients initially presenting with a rupture of the thoracic aorta were enrolled in this study. All patients underwent thoracic endovascular aortic repair (TEVAR). The deployment of the implanted stent graft was assessed by CTA and MRI, comprising the assessment of the aortic arch with and without contrast agent, and the assessment of the motion of the stent graft over the cardiac cycle. The stent graft geometry and motion over the cardiac cycle were assessable by MRI in all patients. Flow-mediated signal variations in areas of flow acceleration could be well visualised. No statistically significant differences in stent-graft diameters were observed between CT and MRI measurements. MRI appears to be a valuable tool for the assessment of thoracic stent grafts. It shows similar performance in the accurate assessment of stent-graft dimensions to the current gold standard CTA. Its capability of providing additional functional information and the lack of ionising radiation and nephrotoxic contrast agents may make MRI a valuable tool for monitoring patients after TEVAR. (orig.)

  17. Takayasu arteritis with middle aortic syndrome and mesenteric ischemia treated by aortic stenting

    Directory of Open Access Journals (Sweden)

    Sarah Morrissey, MD, MA, FRCSC

    2017-09-01

    Full Text Available A 48-year-old woman suffering from Takayasu arteritis presented with middle aortic syndrome consisting of abdominal pain, refractory hypertension with pulmonary edema and pleural effusions, and lower limb ischemia. She failed to improve with high-dose steroid therapy and underwent endovascular stenting of two severe stenoses in the supraceliac and infrarenal aorta. Her symptoms resolved and hypertension improved after the procedure.

  18. Retrograde Stent Placement for Coil Embolization of a Wide-Necked Posterior Inferior Cerebellar Artery Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Hong Gee; Chun, Young IL; Choi, Jin Woo; Cho, Joon; Moon, Won Jin [University College of Medicine, Seoul (Korea, Republic of); Solander, Sten [University of North Carolina School of Medicine, Chapel Hill (United States)

    2012-07-15

    Wide-necked aneurysms of the posterior inferior cerebellar artery (PICA) are infrequently encountered in cerebrovascular practice, and endovascular treatment is difficult or impossible even with the use of several neck remodeling techniques. We present the case of a patient with a wide-necked aneurysm of the PICA, which was treated by the retrograde stenting through the contralateral vertebral artery and vertebrobasilar junction with antegrade coil embolization.

  19. Characterization of an endovascular prosthesis using the 3Bs rule (biocompatibility, biofunctionality and biodurability): a recommended protocol to investigate a device harvested at necropsy.

    Science.gov (United States)

    Xu, Zaipin; Fan, Yubo; Geelkerken, Robert M; Deng, Xiaoyan; King, Martin; Traoré, Amidou; Ingle, Nilesh; Turgeon, Stéphane; McGregor, Robert; Dionne, Guy; Zhang, Ze; Marinov, Georgi R; Legrand, André-Pierre; Guzman, Randolph; Zhang, Hongbo; Yin, Tieying; Douville, Yvan; Nutley, Mark; Renou, Jean-Pierre; Guidoin, Robert

    2007-01-01

    Numerous endovascular stent grafts to treat intrarenal aortic aneurysms are now commercially available, and many new concepts are currently in development worldwide. In order to objectively quantify their outcomes, we propose a detailed protocol to examine a reference device that was harvested from a patient who died a few hours after endovascular stent-graft deployment for an abdominal aortic aneurysm according to the 3Bs rule (biocompatibility, biofunctionality, and biodurability). Relevant patient history of this 63-year-old man included radiotherapy treatment for lung cancer. Following the patient's death, the device was harvested en bloc together with the aneurysmal sac. The analysis of the device was conducted using nondestructive testing (X-rays, CT scan, magnetic resonance imaging [MRI], and endoscopy) and destructive testing (dissection, histology, and fabric and wire component analyses). Results from the gross examination demonstrated that the outer layer of the aneurysm sac was white, stiff, and continuous without any disruption. The Xray analysis, CT scan, and MRI confirmed that the device together with its modular segments was properly deployed at implantation. Endoscopy showed that the device was deployed securely immediately distal to the renal arteries. As anticipated, thin scattered mural thrombi at the blood/foreign material interface were observed on the blood tight flow surface. There were no tears in the fabric, and the dimensions and textile structure were well preserved. The metallic wires were intact. This fatality had no association with the stent graft as the patient's death was caused by the rupture of the pulmonary artery following intensive radiotherapy. In conclusion, autopsy, nondestructive testing, and destructive testing are therefore the necessary steps to validate any explanted endovascular stent graft in terms of biocompatibility, biofunctionality, and biodurability. In this specific case, the endovascular device fulfills the 3Bs

  20. Alternativa técnica no tratamento endovascular dos aneurismas da artéria poplítea A technical alternative for the endovascular treatment of popliteal artery aneurysms

    Directory of Open Access Journals (Sweden)

    Marcelo Ferreira

    2008-03-01

    Full Text Available O aneurisma de artéria poplítea é relativamente raro, porém representa cerca de 85% de todos os aneurismas arteriais periféricos. Apresenta-se geralmente com um quadro de complicação isquêmica e elevado risco de perda do membro acometido. Em função disso, preconiza-se seu tratamento eletivo, atualmente realizado com resultados satisfatórios pela técnica endovascular. Relatamos nossa experiência com a utilização do stent de nitinol auto-expansível revestido com PTFEe - Fluency (Bard, Alemanha, reforçado internamente com o stent de nitinol auto-expansível Zilver (Cook, EUA no tratamento de um aneurisma de artéria poplítea.Popliteal artery aneurysm is relatively rare, but represents around 85% of all peripheral arterial aneurysms. It is usually presented with ischemic complication and high risk of limb loss. For that reason, its elective treatment is indicated and currently carried through with satisfactory results using endovascular techniques. We describe our experience with the use of an ePTFE-covered nitinol self-expandable stent graft - Fluency (Bard, Germany, reinforced internally with the nitinol self-expandable Zilver stent (Cook, USA for the treatment of a popliteal artery aneurism.

  1. A retrievable rescue stent graft and radiofrequency positioning for rapid control of noncompressible hemorrhage.

    Science.gov (United States)

    Chun, Youngjae; Cho, Sung Kwon; Clark, William C; Wagner, William R; Gu, Xinzhu; Tevar, Amit D; McEnaney, Ryan M; Tillman, Bryan W

    2017-08-01

    Noncompressible hemorrhage of the torso remains a challenging surgical dilemma. Stent graft repair requires endovascular expertise, imaging, and inventory that are not available within the critical window of massive hemorrhage. We developed a retrievable stent graft for rapid hemorrhage. We further investigated a radiofrequency (RF) positioning approach as a possible alternative to the logistics of fluoroscopy. A retrievable stent graft was constructed with a novel "petal and stem" design from nitinol and covered with a sleeve of electrospun polyurethane. The stent graft was tested using an in vitro model of simulated hemorrhage. Next, the stent graft was examined in vivo using a porcine model of noncompressible hemorrhage. The stent was examined for hemorrhage control in a porcine model of either aortic or caval injury. An RF reader was assembled from an Arduino processor while RF tags were affixed to the ends of the stent graft. Detection accuracy of a handheld RF wand for an RF tag was quantified both in vitro and through tissue. The retrievable RESCUEstent graft was deployed within minutes and rapidly controlled traumatic hemorrhage angiographically in both aortic injury (n = 3) and caval injury (n = 2). Stent grafts were easily recaptured in both models in under 15 seconds. The LED light of a handheld RF detector illuminated when positioned directly over an RF tag. The RF detection approach revealed positioning accuracy to within 1 cm of the intended target, despite tissue interference. This study demonstrates the rapid deployment and retrieval of a RESCUE stent graft as well as the ability to tamponade injuries of the aorta and cava. In addition, this study demonstrates the feasibility of RF tags to guide stent placement through tissue. More rigorous models are needed to define the effectiveness of this approach in the setting of vascular injury and shock.

  2. Residential fenestration performance analysis using RESFEN3.1

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Y.J.; Mitchell, R.; Arasteh, D.; Selkowitz, S.

    1999-02-01

    This paper describes the development efforts of RESFEN3.1, a PC-based computer program for calculating the heating and cooling energy performance and cost of residential fenestration systems. The development of RESFEN has been coordinated with ongoing efforts by the National Fenestration Rating Council (NFRC) to develop an energy rating system for windows and slqdights to maintain maximum consistency between RESFEN and NFRC's planned energy rating system. Unlike previous versions of RESFEN, that used regression equations to replicate a large database of computer simulations, Version 3.1 produces results based on actual hour-by-hour simulations. This approach has been facilitated by the exponential increase in the speed of personal computers in recent years. RESFEN3.1 has the capability of analyzing the energy performance of windows in new residential buildings in 52 North American locations. The user describes the physical, thermal and optical properties of the windows in each orientation, solar heat gain reductions due to obstructions, overhangs, or shades; and the location of the house. The RESFEN program then models a prototypical house for that location and calculates the energy use of the house using the DOE-2 program. The user can vary the HVAC system, foundation type, and utility costs. Results are presented for the annual heating and cooling energy use, energy cost, and peak energy demand of the house, and the incremental energy use or peak demand attributable to the windows in each orientation. This paper describes the capabilities of RESFEN3.1, its usefulness in analyzing the energy performance of residential windows and its development effort and gives insight into the structure of the computer program. It also discusses the rationale and benefits of the approach taken in RESFEN in combining a simple-to-use graphical front-end with a detailed hour-by-hour ''simulation engine'' to produce an energy analysis tool for the general

  3. Biocompatibility of Coronary Stents

    Directory of Open Access Journals (Sweden)

    Thamarasee M. Jeewandara

    2014-01-01

    Full Text Available Cardiovascular disease is the dominant cause of mortality in developed countries, with coronary artery disease (CAD a predominant contributor. The development of stents to treat CAD was a significant innovation, facilitating effective percutaneous coronary revascularization. Coronary stents have evolved from bare metal compositions, to incorporate advances in pharmacological therapy in what are now known as drug eluting stents (DES. Deployment of a stent overcomes some limitations of balloon angioplasty alone, but provides an acute stimulus for thrombus formation and promotes neointimal hyperplasia. First generation DES effectively reduced in-stent restenosis, but profoundly delay healing and are susceptible to late stent thrombosis, leading to significant clinical complications in the long term. This review characterizes the development of coronary stents, detailing the incremental improvements, which aim to attenuate the major clinical complications of thrombosis and restenosis. Despite these enhancements, coronary stents remain fundamentally incompatible with the vasculature, an issue which has largely gone unaddressed. We highlight the latest modifications and research directions that promise to more holistically design coronary implants that are truly biocompatible.

  4. Stent-assisted coil embolization of a symptomatic middle cerebral artery aneurysm in an infant.

    Science.gov (United States)

    Savastano, Luis E; Chaudhary, Neeraj; Gemmete, Joseph J; Garton, Hugh J L; Maher, Cormac O; Pandey, Aditya S

    2014-11-01

    Pediatric intracranial aneurysms are rare and challenging to treat. Achieving efficacy and durability of aneurysmal occlusion while maintaining parent vessel patency requires innovative treatment strategies, especially in cases in which aneurysmal location or morphology pose substantial morbidity associated with microsurgical treatment. In the last 3 decades, endovascular treatments have had a remarkable evolution and are currently considered safe and effective therapeutic options for cerebral aneurysms. While endovascular techniques are well described in the English literature, the endovascular management of pediatric aneurysms continues to pose a challenge. In this report, the authors describe the case of a 9-month-old infant who presented with a 1-day history of acute-onset left-sided hemiparesis and left facial droop. Imaging revealed a large symptomatic saccular middle cerebral artery aneurysm. Treatment included successful stent-assisted aneurysm coiling. At follow-up, the patient continued to fare well and MR angiography confirmed complete occlusion of the aneurysm dome. This case features the youngest patient in the English literature to harbor an intracranial aneurysm successfully treated with stent-assisted coiling. Based on this experience, endovascular intervention with vascular reconstruction can be safe and effective for the treatment of infants and could further improve prognosis; however, further studies are necessary to confirm these findings.

  5. Percutaneous treatment of superior vena cava syndrome using metallic stents

    Energy Technology Data Exchange (ETDEWEB)

    De Gregorio Ariza, Miguel Angel; Gimeno, Maria Jose; Alfonso, Eduardo; Mainar, Antonio; Medrano, Joaquin; Lopez-Marin, Paloma [Department of Interventional Radiology, ' ' Lozano Blesa' ' University Hospital, Avda. San Juan Bosco 15, 50009 Zaragoza (Spain); Gamboa, Pablo [Division of Interventional Radiology, Ohio State University Hospital, Columbus, Ohio (United States); Tobio, Ricardo [Interventional Radiology, Clinica de la Zarzuela, Madrid (Spain); Herrera, Marcos [Division of Interventional Radiology, University of Minnesota, Minneapolis, Minnesota (United States)

    2003-04-01

    The purpose of this study was to evaluate the results of treatment of superior vena cava syndrome (SVCS) in patients with benign and malignant disease using expandable metallic stent. From January 1995 to April 2000, 87 expandable stents were implanted in 82 patients (59 men, 23 women; mean age 57.8 years, age range 39-79 years) for the treatment of SVCS. The SVCS was defined as symptomatic bilateral obstruction of venous drainage from head, neck and upper extremities. In 68 patients SVCS was due to malignant neoplasia, and in 14 cases it was due to benign aetiology. All patients were treated with expandable stent. We implanted 81 Wallstent prostheses and 6 Palmaz stents. Adjuvant thrombolysis was applied in 12 patients who required fibrinolysis. After recanalization, the stent was implanted in all cases in SVC (infra- or supra-azygos vein). All patients were treated with heparin of low molecular weight (HBPM) during 6 months. Patency was analyzed according to clinical symptoms and Doppler US or venograms exploration. Technical success was observed in all cases. Clinical success was reached in 78 of 82 patients (95.1%) (absence of symptoms in 2 or 3 days). Four patients suffered immediate thrombosis which required fibrinolitic treatment with a new prosthesis placement in 1 case. The follow-up for the malignant process was of 7.1 months (range 1-39 months) and in benign cases was 31.2 months (range 11-61 months). Sixty-two (91.1%) patients with malignancy died without SVCS symptomatology. All the patients with benign pathology are alive. Clinical primary patency in malignant cases was 87% with assisted patency of 96.2%. Endovascular therapy using metallic stent and thrombolysis is a successful method to treat SVCS due to benign or malignant aetiology. (orig.)

  6. Forgotten urological stent.

    Science.gov (United States)

    Bhuiyan, Z H; Bhuiyan, N I; Khan, S A; Tawhid, M H; Islam, M F

    2011-10-01

    "Forgotten" Ureteral stent DJ stent related complication is not uncommon even in the era of modern urology in the developed world. In this context we have undertaken a retro-prospective study in relation to its various causes, complications, management and prevention of forgotten stents in a single teaching institute. The study period was from January'04 to December'09. The sample size was 60. The effect of "forgotten stent" in our study reflects mild UTI to various complications including severe renal failure. We had approached all of our cases judiciously using various modalities of minimal access endourological techniques either alone or in combinations with successful outcome. The study concluded that it is vary easy to prevent "forgotten stent" and so its complications. However if we confront such unwanted complications that could be managed successfully with the use of endourological techniques. We did not use other techniques like laparoscopy and open surgery in this study.

  7. Endovascular treatment of pediatric intracranial aneurysms: a retrospective study of 35 aneurysms.

    Science.gov (United States)

    Takemoto, Koichiro; Tateshima, Satoshi; Golshan, Ali; Gonzalez, Nestor; Jahan, Reza; Duckwiler, Gary; Vinuela, Fernando

    2014-07-01

    Pediatric intracranial aneurysms are rare and not well characterized in comparison with those in adults. To analyze our institution's longitudinal experience of endovascular treatment for pediatric aneurysms to better understand this rare condition. A retrospective record review was performed of patients aged aneurysms between 1995 and 2012. There were 31 patients (average 14.4±4.2 years; 20 male, 11 female) with 35 intracranial aneurysms. The rate of subarachnoid hemorrhage as the initial presentation was 48% and the rates of multiple and giant aneurysms were 13% and 31%, respectively; 28.5% of the cases were posterior circulation aneurysms. Fifteen saccular aneurysms occurred in 14 patients and 17 fusiform aneurysms were noted in 14 patients. Two infectious aneurysms were diagnosed in two patients and one traumatic aneurysm occurred in another patient. Thirty-four aneurysms were treated endovascularly and one had thrombosed spontaneously on a follow-up angiogram. Of the 15 saccular aneurysms, 11 were treated with conventional coiling, one was treated with stent-assisted coiling, one was treated with a flow-diverting stent and two were treated with parent vessel occlusion (PVO). Of the 17 fusiform aneurysms, 15 were treated with PVO with or without prior bypass surgery and one was treated with a flow-diverting stent. The rate of permanent complications and a favorable outcome were 2.9% and 87%, respectively. Endovascular treatment of pediatric aneurysms is technically feasible with an acceptable complication rate despite the high incidence of fusiform aneurysms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  8. Endovascular repair:alternative treatment of ruptured abdominal aortic aneurysm

    Institute of Scientific and Technical Information of China (English)

    GUO Wei; ZHANG Hong-peng; LIU Xiao-ping; YIN Tai; JIA Xin; LIANG Fa-qi; ZHANG Guo-hua

    2009-01-01

    Background As an alternative to open aneurysm repair,endovascular aortic repair(EVAR)has been applied to ruptured abdominal aortic aneurysm(rAAA).The aim of this study was to evaluate the immediate and long-term outcomes of EVAR for rAAA.Methods From July 1997 to September 2007,20 men and six women with rAAA(median age,68 years)were treated with EVAR.Most patients with suspected rAAA underwent emergency computed tomographic angiography(CTA).The procedure was performed under general or local anesthesia.Endovascular clamping was attempted in hemodynamically unstable patients.Bifurcated endografts and aorto-uni-iliac(AUI)endografts with crossover bypass were used.Patients had CT scan prior to discharge,3,6,12 months after discharge,and annually thereafter.Results Time between diagnosis and EVAR ranged from 1 hour to 5 days.EVAR was performed under general anesthesia in 21 patients,and under local anesthesia in five patients.Endovascular aortic clamping was performed in four patients.There was no conversion to open surgery during EVAR.Stent-graft insertion was successful in all patients.One patient died during EVAR from acute myocardial infarction.Ten patients had systolic blood pressure<80 mm Hg.Eleven patients received a blood transfusion.Mean aneurysm size was(47c12)mm.Mean ICU stay was(8±3)days,mean hospital stay(18±6)days,and mean procedure time(120±32)minutes.The 30-day mortality was 23%(6/26patients),and major morbidity 35%(9/26 patients).Early endoleak occurred in 8/26 patients(31%).The mean follow-up was(18±7)months.No patient demonstrated migration of the stent-graft.Conclusions EVAR is a safe and effective option for treatment of acute rAAA,independent of the patient's general condition.Immediate and mid-term outcomes are favorable,but long-term outcome is unknown.Multi-center studies are necessary to establish the role of EVAR for rAAA.

  9. Actual review of diagnostics and endovascular therapy of intracranial arterial stenoses; Diagnostik und endovaskulaere Therapie intrakranieller arterieller Stenosen

    Energy Technology Data Exchange (ETDEWEB)

    Gizewski, E.R. [Universitaetsklinikum Essen (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie; Weber, R. [Universitaetsklinikum Essen (Germany). Klinik fuer Neurologie; Forsting, M. [Universitaetsklinikum Giessen und Marburg, Giessen (Germany). Abt. fuer Neuroradiologie

    2011-02-15

    Approximately 6 - 50 % of all ischemic strokes are caused by intracranial arterial stenosis (IAS). Despite medical prevention, patients with symptomatic IAS have a high annual risk for recurrent ischemic stroke of about 12 %, and up to 19 % in the case of high-grade IAS ({>=} 70 %). Digital subtraction angiography remains the gold standard for the diagnosis and grading of IAS. However, noninvasive imaging techniques including CT angiography, MR angiography, or transcranial Doppler and duplex ultrasound examinations are used in the clinical routine to provide additional information about the brain structure and hemodynamic. However, for technical reasons, the grading of stenoses is sometimes difficult and inaccurate. To date, aspirin is recommended as the treatment of choice in the prevention of recurrent ischemic stroke in patients with IAS. IAS patients who suffer a recurrent ischemic stroke or transient ischemic attack while taking aspirin can be treated with endovascular stenting or angioplasty in specialized centers. The periprocedural complication rate of these endovascular techniques is about 2 - 7 % at experienced neuro-interventional centers. The rate of re-stenosis is reported between 10 and 40 % depending on patient age and stenosis location. Further randomized studies comparing medical secondary prevention and endovascular therapy are currently being performed. With regard to the improvement of endovascular methods and lower complication rates, the indication for endovascular therapy in IAS could be broadened especially for stenosis in the posterior circulation. (orig.)

  10. Endovascular treatment of the subclavian artery aneurysm in high-risk patient - a single-center experience

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2016-01-01

    Full Text Available We present our first experience with endovascular treatment of 6 subclavian artery aneurysms (SAA occurring in five male and one female patient. All patients, in our studies, according to ASA classification were high risk for open repair of SAA. The etiology of the all aneurysms was atherosclerosis degeneration of the artery. Two aneurysms were of intrathoracic location, then the other were extrathoracic. Symptoms related to subclavian artery aneurysms were present in two patients, compression and chest pain in one, and hemorrhage shock in second, while the remaining patients were asymptomatic. We preferred the Viabhan endoprosthesis for endovascular repair in 5 cases. In one patient with ruptured of subclavian artery aneurysm who was high-risk for open repair we made combined endovascular procedure. First at all, we covered the origin of left subclavian artery with thoracic stent graft and after that we put two coils in proximal part of subclavian artery. There was no operative mortality, and the early patency rate was 100%. The follow-up period was from 3 months to 3 years. During this period, one patient died of heart failure and one patient required endovascular reoperation due to endoleak type I. Endovascular treatment is recommended for all patients with subclavian artery aneurysm whenever this is possible due to anatomical reasons especially in high-risk patient with intrathoracic localization of aneurysm, to prevent potential complications.

  11. Everolimus-eluting coronary stents

    Directory of Open Access Journals (Sweden)

    Alejandro Saez

    2010-09-01

    Full Text Available Alejandro Saez, Raul MorenoDivision of Interventional Cardiology, University Hospital La Paz, Madrid, SpainAbstract: Bare metal stents enabled a reduction in the risk of early procedural complications and restenosis in comparison with balloon angioplasty alone, but introduced a new and device-specific iatrogenic condition, ie, in-stent restenosis due to increased neointimal hyperplasia. Sirolimus- and paclitaxel-eluting stents reduce restenosis and the need for new revascularizations in comparison with bare metal stents, although at the cost of a slight increase in the risk of late stent thrombosis and a need for prolonged dual antiplatelet therapy. Everolimus is an analog of sirolimus with an increased solubility. In this review, the currently available evidence for everolimus-eluting stents is revised, including randomized trials against bare metal stents, and head-to-head trials comparing this stent with other drug-eluting stents.Keywords: coronary stents, restenosis, everolimus, review

  12. Emergent stent-assisted angioplasty of extracranial internal carotid artery and intracranial stent-based thrombectomy in acute tandem occlusive disease: technical considerations.

    Science.gov (United States)

    Cohen, José E; Gomori, Moshe; Rajz, Gustavo; Moscovici, Samuel; Leker, Ronen R; Rosenberg, Shai; Itshayek, Eyal

    2013-09-01

    Tandem occlusions of the internal carotid artery (ICA) and a major intracranial artery respond poorly to intravenous thrombolytic therapy, and are usually managed by endovascular means. This study describes experience with stent-assisted endovascular ICA revascularization and stent-based thrombectomy. In patients with tandem ICA-middle cerebral artery (MCA)/distal ICA occlusion, the carotid occlusion was recanalized by primary angioplasty and stent implantation, and the distal occlusion by stent-based thrombectomy. Two variant techniques are described. Seven consecutive patients, mean age 64.1 years (range 49-75) and mean admission National Institutes of Health Stroke Scale score of 23, were included. Occlusion sites were tandem proximal ICA and MCA trunk (six patients) and tandem proximal left ICA and ICA terminus (one patient). Complete recanalization with complete perfusion (Thrombolysis in Myocardial Infarction [TIMI] 3, Thrombolysis in Cerebral Infarction [TICI] 3) was achieved in six patients and partial recanalization with partial perfusion (TIMI 2, TICI 2A) in one. Mean time to therapy was 4.9 h (range 3-6.5); mean time to recanalization was 55 min (range 38-65 min). CT performed 1 day after recanalization showed cortical sparing (>90% of the cortex at risk) in seven patients. Five patients (72%) presented with good clinical outcome (modified Rankin Scale (mRS) score 0-2) at 1 month; one patient (patient No 7) reached an mRS score of 3 and one patient died. In selected cases of acute ICA occlusion and concomitant major vessel embolic stroke, angioplasty and stenting of the proximal occlusion and stent-based thrombectomy of the intracranial occlusion may be feasible, effective and safe, and provide early neurological improvement. Further experience and prospective studies are warranted.

  13. Method to rotate an endovascular device around the axis of a vessel using an external magnetic field.

    Science.gov (United States)

    Florin, E; Rangwala, H S; Rudin, S

    2007-01-01

    A magnetic guidance methodology to rotate a device around the catheter axis is proposed. The specific medical application is to intracranial aneurysms. An endovascular device, the asymmetric stent, has a low porosity region that is rotated to cover the aneurysm neck so as to reduce the blood flow into and hence obliterate the aneurysm. The magnetic guidance system consists of a magnetic device attached to the asymmetric stent and an external homogeneous magnetic field of 0.1 T. This magnetic field puts a torque on the magnetic moment of the magnetic device, thereby rotating the stent for proper orientation. For the magnetic device with the required magnetic moment of 0.001 A m2, a cylindrical neodymium permanent magnet is proposed due to its favorable material characteristics while a coil electromagnet with iron core appears impractical due to demagnetizing effects.

  14. Carotid angioplasty and stenting in the elderly

    Energy Technology Data Exchange (ETDEWEB)

    Kadkhodayan, Yasha [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Cross, DeWitte T.; Moran, Christopher J. [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurological Surgery, St. Louis, MO (United States); Derdeyn, Colin P. [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurological Surgery, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurology, St. Louis, MO (United States)

    2007-11-15

    To investigate the technical success rate as well as the procedural and mid-term complication rates of carotid angioplasty and stenting in elderly patients, a group excluded from large randomized endarterectomy trials given their perceived high surgical risk. Of 200 consecutive carotid angioplasty and/or stenting procedures performed between March 1996 and March 2005, 21 procedures were performed without cerebral protection devices in 20 patients over the age of 79 years (mean age: 83 years, 12 men, eight women). These patients' medical records were retrospectively reviewed for vascular imaging reports and available clinical follow-up. Procedural and mid-term complication rates were calculated and compared to a previously published cohort of 133 consecutive patients {<=}79 years of age who also underwent endovascular treatment at our institution. Carotid stenosis was reduced from a mean of 82% to no significant stenosis in all procedures. The procedural stroke rate was zero of 21 procedures. The procedural transient ischemic attack rate (TIA) was one of 21 procedures (4.8%). Mean follow-up was 24.6 months (range: 1.0-79.5 months) with at least a 30-day follow-up for 20 of the 21 procedures (95.2%). There were no new strokes. There was one recurrent ipsilateral TIA at 1.9 months. In five cases with follow-up carotid ultrasonography, no hemodynamically significant restenosis had occurred. There were three myocardial infarctions (MI) occurring at 0.5, 2.1, and 15.2 months, of which the last MI was fatal. The composite 30-day stroke and death rate was zero of 21 procedures (95% confidence interval: 0-14%). No significant difference was found in the 30-day rate of stroke, TIA, MI, or death between the elderly and younger patients. Carotid angioplasty and stenting in elderly patients can be performed successfully with acceptable procedural and mid-term complication rates comparable to younger patients. (orig.)

  15. Endovascular Therapy Is Effective for Leriche Syndrome with Deep Vein Thrombosis

    Directory of Open Access Journals (Sweden)

    Tasuku Higashihara

    2015-01-01

    Full Text Available A 65-year-old man presented to our hospital due to intermittent claudication and swelling in his left leg. He had Leriche syndrome and deep vein thrombosis. We performed endovascular therapy (EVT for Leriche syndrome, and a temporary filter was inserted in the inferior vena cava. He received anticoagulation therapy for deep vein thrombosis. The stenotic lesion in the terminal aorta was stented with an excellent postprocedural angiographic result and dramatic clinical improvement after EVT. This case suggests that EVT can be a treatment for Leriche syndrome.

  16. Covered Stent Implantation for the Treatment of Direct Carotid-Cavernous Fistula and Its Mid-Term Follow-up

    Science.gov (United States)

    Briganti, F.; Tortora, F.; Marseglia, M.; Napoli, M.; Cirillo, L.

    2009-01-01

    Summary Carotid-cavernous fistulas are abnormal arteriovenous communications either directly between the internal carotid artery and the cavernous sinus or between the dural branches of the internal and external carotid arteries. These fistulas predominantly present with ocular manifestations and they are treated mainly by endovascular techniques in most cases. A detailed review of the literature allowed us to make a complete analysis of the information available on the topic. We describe a case of a direct carotid-cavernous fistula occluded by endovascular implantation of a covered stent, showing the persistence of results after three years. PMID:20465897

  17. Tratamento endovascular em paciente portador de coarctação da aorta: relato de caso Endovascular treatment in a patient with aortic coarctation: case report

    Directory of Open Access Journals (Sweden)

    Eugênio Carlos Almeida Tinoco

    2007-03-01

    Full Text Available Coarctação da aorta constitui um estreitamento de origem congênita na porção inicial da aorta torácica. Tem incidência de 6 a 8% em nascidos vivos. A apresentação clínica é variada. O tratamento de escolha é o cirúrgico. Relatamos um caso de paciente do sexo feminino de 31 anos, com queixa de dor constrictiva na região cervical, dispnéia e claudicação intermitente em membros inferiores, sendo diagnosticada coarctação da aorta associada a estenose aórtica grave, que foi tratada com combinação das técnicas implantação de stent endovascular e angioplastia por balão.Aortic coarctation is a congenital stenosis in the initial portion of the thoracic aorta. Its incidence ranges between 6-8% of liveborns. Clinical presentations are diversified. The treatment of choice is surgery. We report the case of a 31-year-old female patient with constrictive pain in the cervical region, dyspnea, and intermittent claudication of the lower limbs. She was diagnosed with aortic coarctation associated with severe aortic stenosis, which was treated using a combination of endovascular stent implantation and balloon angioplasty.

  18. Open aortic surgery after thoracic endovascular aortic repair.

    Science.gov (United States)

    Coselli, Joseph S; Spiliotopoulos, Konstantinos; Preventza, Ourania; de la Cruz, Kim I; Amarasekara, Hiruni; Green, Susan Y

    2016-08-01

    In the last decade, thoracic endovascular aortic aneurysm repair (TEVAR) has emerged as an appealing alternative to the traditional open aortic aneurysm repair. This is largely due to generally improved early outcomes associated with TEVAR, including lower perioperative mortality and morbidity. However, it is relatively common for patients who undergo TEVAR to need a secondary intervention. In select circumstances, these secondary interventions are performed as an open procedure. Although it is difficult to assess the rate of open repairs after TEVAR, the rates in large series of TEVAR cases (>300) have ranged from 0.4 to 7.9 %. Major complications of TEVAR that typically necessitates open distal aortic repair (i.e., repair of the descending thoracic or thoracoabdominal aorta) include endoleak (especially type I), aortic fistula, endograft infection, device collapse or migration, and continued expansion of the aneurysm sac. Conversion to open repair of the distal aorta may be either elective (as for many endoleaks) or emergent (as for rupture, retrograde complicated dissection, malperfusion, and endograft infection). In addition, in select patients (e.g., those with a chronic aortic dissection), unrepaired sections of the aorta may progressively dilate, resulting in the need for multiple distal aortic repairs. Open repairs after TEVAR can be broadly classified as full extraction, partial extraction, or full salvage of the stent-graft. Although full and partial stent-graft extraction imply failure of TEVAR, such failure is generally absent in cases where the stent-graft can be fully salvaged. We review the literature regarding open repair after TEVAR and highlight operative strategies.

  19. Tratamento endovascular da reestenose carotídea: resultados em curto prazo Endovascular treatment of carotid artery restenosis: short term results

    Directory of Open Access Journals (Sweden)

    Ricardo Augusto Carvalho Lujan

    2011-03-01

    Full Text Available CONTEXTO: O tratamento cirúrgico da reestenose carotídea apresenta alta taxa de lesão neurológica. Contrariamente, o tratamento endovascular da doença obstrutiva carotídea extracraniana tem se tornado mais factível e gradualmente menores taxas de risco cirúrgico vêm sendo reportadas, tornando-se uma opção em situações especiais, e provavelmente poderá ser considerado o tratamento padrão para reestenose carotídea. OBJETIVOS: Avaliar a aplicabilidade, a segurança e a eficácia da angioplastia com o uso do stent (ACS no tratamento da reestenose carotídea (REC no intraoperatório e no pós-operatório recente (80%, enquanto quatro (21% eram sintomáticos com estenose >70%. Apenas em um paciente não foi utilizado sistema de proteção cerebral. O sucesso técnico foi obtido em todos os casos. Não houve morte ou acidente vascular encefálico no intra ou no pós-operatório recente (30 dias. CONCLUSÃO: O tratamento endovascular da reestenose carotídea mostrou-se uma abordagem factível e segura em curto prazoCONTEXT: The surgical treatment of carotid artery restenosis presents a high risk of nerve injury. On the contrary, endovascular treatment for extracranial carotid artery obstructive disease has become more feasible. Gradually, lower rates of surgical risk have been reported, which makes the treatment a good option in special situations. It may be considered as the standard treatment for carotid artery restenosis. OBJECTIVE: To evaluate the applicability, safety, and efficacy of the angioplasty with the use of a stent (Carotid Artery Stenting - CAS for the treatment of carotid artery restenosis, in the intraoperative and early (80%, whereas 4 (21% were symptomatic with stenosis >70%. In only one patient a cerebral protection system was not used. Technical success was achieved in all cases. There was no death or stroke in the intraoperative or the early postoperative period (30 days. CONCLUSION: Endovascular treatment of

  20. Combined surgical and endovascular approach to treat a complex aortic coarctation without extracorporeal circulation.

    Science.gov (United States)

    Carrel, Thierry P; Berdat, Pascal A; Baumgartner, Iris; Dinkel, Hans-Peter; Schmidli, Jürg

    2004-10-01

    Various therapeutic approaches have been proposed to treat complex coarctation of the aorta (eg, recoarctation, which requires repetitive interventions, or coarctation with a hypoplastic aortic arch). Resection followed by end-to-end anastomosis or by graft interposition is technically demanding and exposes the patient to considerable perioperative risks. Cardiopulmonary bypass and deep hypothermic circulatory arrest may be necessary to control the distal aortic arch. The role of stent technology in treating this type of lesion has not yet been defined. We present a 21-year-old woman with a recurrent coarctation of the aorta associated with a hypoplastic aortic arch and a pseudoaneurysm of the proximal descending aorta. She had undergone 4 previous interventions. Treatment consisted of a combined surgical and endovascular approach without cardiopulmonary bypass and included extraanatomic aortic bypass, partial debranching of the supraaortic vessels, and stent-graft insertion to exclude the aneurysm.

  1. Safety and efficacy of transhepatic and transsplenic access for endovascular management of portal vein complications after liver transplantation.

    Science.gov (United States)

    Ohm, Joon-Young; Ko, Gi-Young; Sung, Kyu-Bo; Gwon, Dong-Il; Ko, Heung Kyu

    2017-09-01

    The purpose of this article is to evaluate and compare the safety and efficacy of endovascular management of the portal vein (PV) via percutaneous transsplenic access versus percutaneous transhepatic access in liver transplantation (LT) recipients. A total of 18 patients who underwent endovascular management of PV via percutaneous transhepatic (n = 8) and transsplenic (n = 10) access were enrolled. Transsplenic access was chosen if the spleen was located in a normal position, the splenic vein (SpV) was preserved, and the target lesion did not involve confluence of the superior mesenteric and SpVs. Accessibility of the percutaneous transsplenic puncture was confirmed via ultrasound (US) in the angiography suite. All procedures were performed under local anesthesia. Percutaneous transhepatic or transsplenic access was performed using a 21-gauge Chiba needle under US and fluoroscopic guidance, followed by balloon angioplasty, stent placement, or variceal embolization. The access tract was embolized using coils and a mixture (1:2) of glue and ethiodized oil. Transhepatic or transsplenic access was successfully achieved in all patients. A total of 12 patients underwent stent placement; 3 had balloon angioplasty only; 2 had variceal embolization only; and 1 had variceal embolization followed by successful stent placement. Regarding major complications, 1 patient experienced a SpV tear with extravasation during transsplenic balloon angioplasty, which was successfully managed using temporary balloon inflation, followed by transfusion. Clinical success was achieved in 9 of 11 (82%) patients who exhibited clinical manifestations. The remaining 7 patients who underwent prophylactic endovascular management were healthy. In conclusion, endovascular management of PV via percutaneous transsplenic access is a relatively safe and effective alternative that does not damage the liver grafts of LT recipients. Liver Transplantation 23 1133-1142 2017 AASLD. © 2017 by the American

  2. On the Mechanical Properties and Microstructure of Nitinol forBiomedical Stent Applications

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, Scott W. [Univ. of California, Berkeley, CA (United States)

    2006-01-01

    This dissertation was motivated by the alarming number of biomedical device failures reported in the literature, coupled with the growing trend towards the use of Nitinol for endovascular stents. The research is aimed at addressing two of the primary failure modes in Nitinol endovascular stents: fatigue-crack growth and overload fracture. The small dimensions of stents, coupled with their complex geometries and variability among manufacturers, make it virtually impossible to determine generic material constants associated with specific devices. Instead, the research utilizes a hybrid of standard test techniques (fracture mechanics and x-ray micro-diffraction) and custom-designed testing apparatus for the determination of the fracture properties of specimens that are suitable representations of self-expanding Nitinol stents. Specifically, the role of texture (crystallographic alignment of atoms) and the austenite-to-martensite phase transformation on the propagation of cracks in Nitinol was evaluated under simulated body conditions and over a multitude of stresses and strains. The results determined through this research were then used to create conservative safe operating and inspection criteria to be used by the biomedical community for the determination of specific device vulnerability to failure by fracture and/or fatigue.

  3. On the mechanical properties and microstructure of Nitinol for biomedical stent applications

    Science.gov (United States)

    Robertson, Scott Wade

    This dissertation was motivated by the alarming number of biomedical device failures reported in the literature, coupled with the growing trend towards the use of Nitinol for endovascular stents. The research is aimed at addressing two of the primary failure modes in Nitinol endovascular stents: fatigue-crack growth and overload fracture. The small dimensions of stents, coupled with their complex geometries and variability among manufacturers, make it virtually impossible to determine generic material constants associated with specific devices. Instead, the research utilizes a hybrid of standard test techniques (fracture mechanics and x-ray micro-diffraction) and custom-designed testing apparatus for the determination of the fracture properties of specimens that are suitable representations of self-expanding Nitinol stents. Specifically, the role of texture (crystallographic alignment of atoms) and the austenite-to-martensite phase transformation on the propagation of cracks in Nitinol was evaluated under simulated body conditions and over a multitude of stresses and strains. The results determined through this research were then used to create conservative safe operating and inspection criteria to be used by the biomedical community for the determination of specific device vulnerability to failure by fracture and/or fatigue.

  4. Outcomes of thoracic endovascular aortic repair in adult coarctation patients.

    Science.gov (United States)

    Lala, Salim; Scali, Salvatore T; Feezor, Robert J; Chandrekashar, Satish; Giles, Kristina A; Fatima, Javairiah; Berceli, Scott A; Back, Martin R; Huber, Thomas S; Beaver, Thomas M; Beck, Adam W

    2017-09-22

    Aortic coarctation (AC) is most commonly identified in pediatric patients; however, adults can present with late sequelae of untreated coarctation or complications of prior open repair. To date, there are limited data about the role of thoracic endovascular aortic repair (TEVAR) in this group of patients. The purpose of this analysis was to describe our experience with management of adult coarctation patients using TEVAR. All TEVAR patients treated for primary coarctation or late sequelae of previous open repair (eg, pseudoaneurysm, recurrent coarctation or anastomotic stenosis related to index open coarctation repair) were reviewed. Demographics, comorbidities, procedure-related variables, postoperative outcomes, and reintervention were recorded. Computed tomography centerline assessments of endograft morphology were completed to delineate stent anatomy at the coarctation site. Survival and reintervention were estimated using life-table analysis. A total of 21 patients were identified (median age, 46 years [range, 33-71 years]; 67% male [n = 14]). Nine patients (43%) were treated for symptomatic primary (n = 6) or recurrent (n = 3) coarctation. Other indications included degenerative thoracic aneurysm (n = 6), pseudoaneurysm (n = 4), and dissection (n = 2). Technical success was 100% (95% confidence interval [CI], 84%-100%). No 30-day mortality or paraplegia events occurred; however, two patients (10%) experienced postoperative nondisabling stroke. In primary or recurrent coarctation patients with available computed tomography imaging (n = 8 of 9), nominal stent graft diameters were achieved proximal and distal to the coarctation (range, -0.4 to -1.2 mm of desired final stent diameter). Specific to the coarctation site, there was a significant increase in aortic diameter after TEVAR (before stenting, 11.5 [95% CI, 6.8-12.3] mm; after stenting, 15 [95% CI, 13.7-15.7] mm; P = .004). Concurrently, systolic arterial blood pressure at time of discharge was

  5. Emergency and elective implantation of covered stent systems in iatrogenic arterial injuries

    Energy Technology Data Exchange (ETDEWEB)

    Goltz, J.P.; Kickuth, R. [Universitaetsklinikum Wuerzburg (Germany). Inst. fuer Roentgendiagnostik; Bastuerk, P.; Hoppe, H.; Triller, J. [Universitaetsspital Bern (Switzerland). Inst. fuer Diagnostische, Interventionelle und Paediatrische Radiologie

    2011-07-15

    Purpose: To evaluate the effectiveness and safety of covered stents for the management of iatrogenic arterial injury. Materials and Methods: Between 03/1998 and 12/2009, 31 patients underwent selective covered stent implantation after iatrogenic arterial injury. 12/31 of these patients (38.7 %) were hemodynamically unstable. Six different endovascular covered stent types were utilized. The primary endpoints of this study were technical and clinical success and rates of minor and major complications. Results: Initial angiograms demonstrated active extravasation in 19 (61.3 %) patients and pseudoaneurysms in 12 (38.7 %) patients. The following sites of bleeding origin were detected: axillary artery, subclavian artery, common iliac artery, external iliac artery, internal iliac artery, common femoral artery, superficial femoral artery, popliteal and fibular artery, femoro-popliteal and popliteo-crural bypasses, common hepatic artery, aberrant hepatic artery, cystic and gastroduodenal artery. In all patients bleeding was effectively controlled by covered stent implantation resulting in an immediate technical success of 100 %. Clinical success attributed to covered stent implantation was documented in 30 of the 31 patients (96.8 %). Major complications included death in four patients (11.1 %), acute thrombosis with arm ischemia in one patient (2.8 %) and stent fracture with associated pseudoaneurysm in another patient (2.8 %). In 2/31 patients (6.5 %) covered stent failure was detected and successfully treated by implantation of a second covered stent. Conclusion: Emergency and elective implantation of covered stents may be used for minimally invasive and effective management of iatrogenic arterial injury. (orig.)

  6. Validation of an image registration and segmentation method to measure stent graft motion on ECG-gated CT using a physical dynamic stent graft model

    Science.gov (United States)

    Koenrades, Maaike A.; Struijs, Ella M.; Klein, Almar; Kuipers, Henny; Geelkerken, Robert H.; Slump, Cornelis H.

    2017-03-01

    The application of endovascular aortic aneurysm repair has expanded over the last decade. However, the long-term performance of stent grafts, in particular durable fixation and sealing to the aortic wall, remains the main concern of this treatment. The sealing and fixation are challenged at every heartbeat due to downward and radial pulsatile forces. Yet knowledge on cardiac-induced dynamics of implanted stent grafts is sparse, as it is not measured in routine clinical follow-up. Such knowledge is particularly relevant to perform fatigue tests, to predict failure in the individual patient and to improve stent graft designs. Using a physical dynamic stent graft model in an anthropomorphic phantom, we have evaluated the performance of our previously proposed segmentation and registration algorithm to detect periodic motion of stent grafts on ECG-gated (3D+t) CT data. Abdominal aortic motion profiles were simulated in two series of Gaussian based patterns with different amplitudes and frequencies. Experiments were performed on a 64-slice CT scanner with a helical scan protocol and retrospective gating. Motion patterns as estimated by our algorithm were compared to motion patterns obtained from optical camera recordings of the physical stent graft model in motion. Absolute errors of the patterns' amplitude were smaller than 0.28 mm. Even the motion pattern with an amplitude of 0.23 mm was measured, although the amplitude of motion was overestimated by the algorithm with 43%. We conclude that the algorithm performs well for measurement of stent graft motion in the mm and sub-mm range. This ultimately is expected to aid in patient-specific risk assessment and improving stent graft designs.

  7. Emergency stenting to control massive bleeding of injured iliac artery following lumbar disk surgery

    Energy Technology Data Exchange (ETDEWEB)

    Bierdrager, Edwin; Rooij, Willem Jan van; Sluzewski, Menno [Department of Radiology, St. Elisabeth Ziekenhuis, Tilburg (Netherlands)

    2004-05-01

    The purpose of this study was to demonstrate the use of endovascular stenting to repair an iliac artery injury following lumbar discectomy, thus obviating the need for major surgery. A 57-year-old woman developed a distended abdomen and signs of hypovolemic shock immediately following discectomy at the L4-L5 level. Ultrasound showed a large amount of abdominal fluid. Angiography revealed a laceration of the right iliac artery bifurcation with extravasation of contrast material. After occlusion of the internal iliac artery with fibered coils to prevent retrograde flow to the iliac bifurcation, a self-expanding covered stent was inserted to seal the iliac laceration. The leakage of blood stopped immediately. The clinical condition of the patient gradually improved and she was discharged home 5 weeks later. Sealing of arterial laceration as a complication of lumbar disc surgery with a covered stent is a simple and effective alternative to major pelvic surgery. (orig.)

  8. Computational comparison of the bending behavior of aortic stent-grafts

    CERN Document Server

    Demanget, Nicolas; Badel, Pierre; Orgéas, Laurent; Geindreau, Christian; Albertini, Jean-Noël; Favre, Jean-Pierre; 10.1016/j.jmbbm.2011.09.006

    2012-01-01

    Secondary interventions after endovascular repair of abdominal aortic aneurysms are frequent because stent-graft (SG) related complications may occur (mainly endoleak and SG thrombosis). Complications have been related to insufficient SG flexibility, especially when devices are deployed in tortuous arteries. Little is known on the relationship between SG design and flexibility. Therefore, the aim of this study was to simulate numerically the bending of two manufactured SGs (Aorfix-Lombard Medical (A) and Zenith-Cook Medical Europe (Z)) using finite element analysis (FEA). Global SG behavior was studied by assessing stent spacing variation and cross-section deformation. Four criteria were defined to compare flexibility of SGs: maximal luminal reduction rate, torque required for bending, maximal membrane strains in graft and maximal Von Mises stress in stents. For angulation greater than 60\\degree, values of these four criteria were lower with A-SG, compared to Z-SG. In conclusion, A-SG was more flexible than Z...

  9. Endovascular Treatment of Infrarenal Abdominal Aortic Lesions With or Without Common Iliac Artery Involvement

    Energy Technology Data Exchange (ETDEWEB)

    Oender, Hakan, E-mail: drhakanonder@hotmail.com [Dicle University Medical Faculty, Department of Radiology (Turkey); Oguzkurt, Levent [Baskent University Medical Faculty, Department of Radiology (Turkey); Guer, Serkan [Sifa University Medical Faculty, Department of Radiology (Turkey); Tekbas, Gueven [Dicle University Medical Faculty, Department of Radiology (Turkey); Guerel, Kamil [Abant Izzet Baysal University Medical Faculty, Department of Radiology (Turkey); Coskun, Isa [Baskent University Medical Faculty, Department of Cardiovascular Surgery (Turkey); Oezkan, Ugur [Baskent University Medical Faculty, Department of Radiology (Turkey)

    2013-02-15

    To evaluate the results of stent placement for obstructive atherosclerotic aortic disease with or without involvement of the common iliac artery. Forty patients had self-expanding stents primarily or after balloon dilatation in the abdominal aorta between January 2005 and May 2011. All patients had trouble walking. Follow-up examinations were performed with clinical visits; these included color Doppler ultrasonography and computed tomographic angiography. Technical, clinical, and hemodynamic success was achieved in all patients. None of the patients underwent reintervention during the follow-up period, which ranged from 3 months to 6 years (median 24 months). Nine complications occurred in six patients. Of the nine complications, four were distal thromboembolisms, which were successfully treated with catheter-directed thrombolysis or anticoagulation therapy. Endovascular treatment of the obstructive aortic disease using self-expanding stents was safe and effective, with high technical success and long-term patency. Thromboembolic complications were high even though direct stenting was considered protective for thromboembolism formation. Particularly for infrarenal aortic stenosis, it can be recommended as the first-line treatment option for patients with obstructive atherosclerotic aortic disease.

  10. Are there fewer complications with third generation endografts in endovascular aneurysm repair?

    DEFF Research Database (Denmark)

    Jayia, P; Constantinou, J; Morgan-Rowe, L

    2013-01-01

    Endovascular aneurysm repair (EVAR) is widely accepted as a safe technique for treatment of aortic diseases since the concept was first pioneered by Volodos in 1986 and Parodi in 1991. Numerous registries have shown that this minimally invasive technique is associated with lower mortality when co...... generation endografts in challenging anatomy has yielded encouraging results. With regards to short and midterm outcome and need for secondary interventions, evaluations shows comparable results with all devices performing well....... compared to open surgery in short and mid-term follow-up. The first pioneer devices had a high failure rate due to stent migration. This led to the creation of the first generation stent-grafts, which were associated with complications such as thrombosis of the limbs, graft migration and major endoleaks...... devices led to the development of the second generation stent-grafts. The improvements with regards to the delivery systems, enabled reposition of the top-stent following deployment in some devices. The number of devices commercially available increased with the second generation. The third generation...

  11. In vitro validation of flow measurements in an aortic nitinol stent graft by velocity-encoded MRI

    Energy Technology Data Exchange (ETDEWEB)

    Rengier, Fabian, E-mail: f.rengier@dkfz.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); German Cancer Research Center (dkfz) Heidelberg, Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Delles, Michael, E-mail: delles@kit.edu [Karlsruhe Institute of Technology (KIT), Department of Informatics, Institute for Anthropomatics, Adenauerring 2, 76131 Karlsruhe (Germany); Weber, Tim Frederik, E-mail: Tim.Weber@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Boeckler, Dittmar, E-mail: dboeckler@me.com [University Hospital Heidelberg, Department of Vascular and Endovascular Surgery, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Ley, Sebastian, E-mail: ley@gmx.net [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Kauczor, Hans-Ulrich, E-mail: Hans-Ulrich.Kauczor@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Tengg-Kobligk, Hendrik von, E-mail: h.vontengg@dkfz.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); German Cancer Research Center (dkfz) Heidelberg, Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany)

    2011-10-15

    Purpose: To validate flow measurements within an aortic nickel-titanium (nitinol) stent graft using velocity-encoded cine magnetic resonance imaging (VEC MRI) and to assess intraobserver agreement of repeated flow measurements. Materials and methods: An elastic tube phantom mimicking the descending aorta was developed with the possibility to insert an aortic nitinol stent graft. Different flow patterns (constant, sinusoidal and pulsatile aortic flow) were applied by a gear pump. A two-dimensional phase-contrast sequence was used to acquire VEC perpendicular cross-sections at six equidistant levels along the phantom. Each acquisition was performed twice with and without stent graft, and each dataset was analysed twice by the same reader. The percental difference of the measured flow volume to the gold standard (pump setting) was defined as the parameter for accuracy. Furthermore, the intraobserver agreement was assessed. Results: Mean accuracy of flow volume measurements was -0.45 {+-} 1.63% without stent graft and -0.18 {+-} 1.45% with stent graft. Slightly lower accuracy was obtained for aortic flow both without (-2.31%) and with (-1.29%) stent graft. Accuracy was neither influenced by the measurement position nor by repeated acquisitions. There was significant intraobserver agreement with an intraclass correlation coefficient of 0.87 (without stent graft, p < 0.001) and 0.80 (with stent graft, p < 0.001). The coefficient of variance was 0.25% without stent graft and 0.28% with stent graft. Conclusion: This study demonstrated high accuracy and excellent intraobserver agreement of flow measurements within an aortic nitinol stent graft using VEC MRI. VEC MRI may give new insights into the haemodynamic consequences of endovascular aortic repair.

  12. An Unusual Cause of Pediatric Stroke Secondary to Congenital Basilar Artery Fenestration

    Directory of Open Access Journals (Sweden)

    J. J. Gold

    2013-01-01

    Full Text Available Basilar artery fenestration is an uncommon congenital variant that has been associated with aneurysms and posterior circulation infarcts in the adult literature. Little is known about the functional consequences of basilar artery fenestration, if any, in childhood. We present a case of a previously healthy 12-year-old boy who presented with diplopia, tinnitus, and ataxia who had subtle findings on diffusion-weighted magnetic resonance imaging consistent with posterior circulation territory infarction. Computed tomography angiography and magnetic resonance angiography revealed an area of signal abnormality in the basilar artery, which was confirmed on conventional angiography to be a type 2 basilar artery fenestration, without thrombus or aneurysm. The patient recovered from his neurologic deficits over two days and was placed on prophylactic aspirin therapy without recurrence of symptoms. This rare anatomic variant of the posterior circulation is important for physicians to recognize and may have associated neurologic consequences during childhood worthy of further investigation.

  13. Placement of endosseous implant in infected alveolar socket with large fenestration defect: A comparative case report

    Directory of Open Access Journals (Sweden)

    Balaji Anitha

    2010-01-01

    Full Text Available Placement of endosseous implants into infected bone is often deferred or avoided due to fear of failure. However, with the development of guided bone regeneration [GBR], some implantologists have reported successful implant placement in infected sockets, even those with fenestration defects. We had the opportunity to compare the osseointegration of an immediate implant placed in an infected site associated with a large buccal fenestration created by the removal of a root stump with that of a delayed implant placed 5 years after extraction. Both implants were placed in the same patient, in the same dental quadrant by the same implantologist. GBR was used with the fenestration defect being filled with demineralized bone graftFNx01 and covered with collagen membraneFNx08. Both implants were osseointegrated and functional when followed up after 12 months.

  14. Massive Ascites in a Renal Transplant Patient after Laparoscopic Fenestration of a Lymphocele

    Directory of Open Access Journals (Sweden)

    Shohei Kawaguchi

    2016-01-01

    Full Text Available Retroperitoneal lymphocele is a common complication of renal transplantation. Here, we report the case of a 67-year-old woman with massive ascites after fenestration surgery for a lymphocele that developed following renal transplantation. She had been on continuous ambulatory peritoneal dialysis for 9 years. Living donor renal transplantation was performed and an intrapelvic lymphocele subsequently developed. The lymphocele did not resolve after aspiration therapy; therefore, laparoscopic fenestration was performed. Although the lymphocele disappeared, massive ascites appeared in its stead. Half a year later, the ascites was surgically punctured, which then gradually resolved and disappeared 6 weeks later. Aspiration therapy should be considered in patients on long-term peritoneal dialysis, although laparoscopic fenestration is safe and effective.

  15. Management of mucosal fenestration with external root resorption by multidisciplinary approach.

    Science.gov (United States)

    Bharti, Ramesh; Chandra, Anil; Tikku, Aseem Prakash; Prasad, Veerendra; Shakya, Vijay Kumar; Singhal, Rameshweri

    2014-10-09

    Mucosal fenestration is a clinical condition in which the overlying gingiva is denuded and the root is exposed to the oral cavity. Invasive cervical resorption is an entirely uncommon entity and its aetiology is poorly understood. This case presents an invasive cervical resorption of maxillary right central incisor with fenestration at the cervical third of the tooth. The resorption area was chemomechanically debrided. It was then restored with Mineral Trioxide Aggregate over which pink glass ionomer cement (GC Fuji VII) was placed. Lateral pedicle flap was used to cover the fenestration. The resorptive defect was restored using tooth coloured restorative resin after removal of the pink glass ionomer cement. Orthodontic treatment was continued for correction of malocclusion.

  16. The diaphragms of fenestrated endothelia – gatekeepers of vascular permeability and blood composition

    Science.gov (United States)

    Stan, Radu V.; Tse, Dan; Deharvengt, Sophie J.; Smits, Nicole C.; Xu, Yan; Luciano, Marcus R.; McGarry, Caitlin L.; Buitendijk, Maarten; Nemani, Krishnamurthy V.; Elgueta, Raul; Kobayashi, Takashi; Shipman, Samantha L.; Moodie, Karen L.; Daghlian, Charles P.; Ernst, Patricia A.; Lee, Hong-Kee; Suriawinata, Arief A.; Schned, Alan R.; Longnecker, Daniel S.; Fiering, Steven N.; Noelle, Randolph J.; Gimi, Barjor; Shworak, Nicholas W.; Carrière, Catherine

    2012-01-01

    SUMMARY Fenestral and stomatal diaphragms are endothelial subcellular structures of unknown function that form on organelles implicated in vascular permeability: fenestrae, transendothelial channels and caveolae. PV1 protein is required for diaphragm formation in vitro. Here, we report that deletion of the PV1-encoding Plvap gene in mice results in the absence of diaphragms and decreased survival. Loss of diaphragms did not affect the fenestrae and transendothelial channels formation but disrupted the barrier function of fenestrated capillaries causing a major leak of plasma proteins. This disruption results in early death of animals due to severe non-inflammatory protein loosing enteropathy. Deletion of PV1 in endothelium, but not the hematopoietic compartment, recapitulates the phenotype of global PV1 deletion, whereas endothelial reconstitution of PV1 rescues the phenotype. Taken together, these data provide genetic evidence for the critical role of the diaphragms in fenestrated capillaries in the maintenance of blood composition. PMID:23237953

  17. The diaphragms of fenestrated endothelia: gatekeepers of vascular permeability and blood composition.

    Science.gov (United States)

    Stan, Radu V; Tse, Dan; Deharvengt, Sophie J; Smits, Nicole C; Xu, Yan; Luciano, Marcus R; McGarry, Caitlin L; Buitendijk, Maarten; Nemani, Krishnamurthy V; Elgueta, Raul; Kobayashi, Takashi; Shipman, Samantha L; Moodie, Karen L; Daghlian, Charles P; Ernst, Patricia A; Lee, Hong-Kee; Suriawinata, Arief A; Schned, Alan R; Longnecker, Daniel S; Fiering, Steven N; Noelle, Randolph J; Gimi, Barjor; Shworak, Nicholas W; Carrière, Catherine

    2012-12-11

    Fenestral and stomatal diaphragms are endothelial subcellular structures of unknown function that form on organelles implicated in vascular permeability: fenestrae, transendothelial channels, and caveolae. PV1 protein is required for diaphragm formation in vitro. Here, we report that deletion of the PV1-encoding Plvap gene in mice results in the absence of diaphragms and decreased survival. Loss of diaphragms did not affect the fenestrae and transendothelial channels formation but disrupted the barrier function of fenestrated capillaries, causing a major leak of plasma proteins. This disruption results in early death of animals due to severe noninflammatory protein-losing enteropathy. Deletion of PV1 in endothelium, but not in the hematopoietic compartment, recapitulates the phenotype of global PV1 deletion, whereas endothelial reconstitution of PV1 rescues the phenotype. Taken together, these data provide genetic evidence for the critical role of the diaphragms in fenestrated capillaries in the maintenance of blood composition.

  18. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels;

    2013-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...... is a rare, but potential life threatening event after coronary stent implantation. The etiology seems to be multifactorial....

  19. Complications of Aortic Stenting in Patients below 20 Years Old: Immediate and Intermediate Follow-Up

    Directory of Open Access Journals (Sweden)

    Akbar Molaei

    2011-12-01

    Full Text Available Background: Optimal timing and mode of treatment for patients with coarctation of the aorta (COA remain controversial, particularly in children. Surgery, balloon dilatation, and stent implantation have all proven effective in the treatment of moderate or severe obstruction. The aim of this study was to investigate the complications of COA stenting angioplasty in pediatric patients. Methods: This retrospective, descriptive study was conducted on patients less than 20 years of age who underwent aortic stenting angioplasty because of congenital COA in the pediatric catheterization laboratory of Rajaie cardiovascular, medical and research Center, Tehran between 2005 and 2010. Results: A total of 26 patients (18 [65.4%] males and 9 [34.6%] females with congenital COA who had undergone aortic stenting angioplasty were recruited. Nineteen (73.1% of these patients had native COA and 7 (26.9% had recurrent COA. Most of the early complications were minor and temporary; only one patient developed early major complications. During the follow-up, whereas none of the native group patients developed late complications, in the re-COA group 28.57% of the patients had re-stenosis and 14.28% had chronic systemic hypertension, requiring drug therapy. Conclusion: Our investigation into post-stenting complications in patients with native COA and re-COA showed that endovascular stenting could be an effective and safe method, even in young patients with native COA.

  20. Effect of Stent Radial Force on Stress Pattern After Deployment: A Finite Element Study

    Science.gov (United States)

    Borghi, Alessandro; Murphy, Olive; Bahmanyar, Reza; McLeod, Chris

    2014-07-01

    The present article presents a method for assessing the radial stiffness of nitinol stents. An idealized stent model was created, and its radial stiffness was calculated by means of finite element modeling. The calculations were validated against experimental measurements. The variation of radial stiffness with geometrical dimensions was calculated, and the effect of increasing radial stiffness on endovascular deployment was analyzed. Peak tensile and compressive stresses as well as stent penetration were calculated in the case of an idealized pulmonary artery model having realistic dimensions as well as stiffness. The results of stress calculations were compared with a second set of simulations, where an idealized behavior of the stent (uniform expansion to a theoretical contact diameter) was modeled. The results show how in reality nitinol stents behave in a non-ideal way, having a non-uniform expansion and exerting non-uniform pressure on the contact areas with the artery. Such non-ideality decreases though with the increase in radial stiffness. The radial force alone may be insufficient in describing the stent-artery interaction, and numerical modeling proves to be necessary for capturing such complexity.

  1. Endovascular blood flow measurement system

    Science.gov (United States)

    Khe, A. K.; Cherevko, A. A.; Chupakhin, A. P.; Krivoshapkin, A. L.; Orlov, K. Yu

    2016-06-01

    In this paper an endovascular measurement system used for intraoperative cerebral blood flow monitoring is described. The system is based on a Volcano ComboMap Pressure and Flow System extended with analogue-to-digital converter and PC laptop. A series of measurements performed in patients with cerebrovascular pathologies allows us to introduce “velocity-pressure” and “flow rate-energy flow rate” diagrams as important characteristics of the blood flow. The measurement system presented here can be used as an additional instrument in neurosurgery for assessment and monitoring of the operation procedure. Clinical data obtained with the system are used for construction of mathematical models and patient-specific simulations. The monitoring of the blood flow parameters during endovascular interventions was approved by the Ethics Committee at the Meshalkin Novosibirsk Research Institute of Circulation Pathology and included in certain surgical protocols for pre-, intra- and postoperative examinations.

  2. Development of a dynamic in vitro model of a stented blood vessel to evaluate the effects of stent strut material selection and surface coating on smooth muscle cell response

    Science.gov (United States)

    Winn, Bradley Huegh

    formation of this new tissue, primarily consisting of VSMCs of the synthetic phenotype and their subsequent extracellular matrix, is the sole causation of in-stent restenosis since the stent serves to prevent elastic recoil and negative remodeling. This doctoral research program is focused on endovascular stent biomaterials science and engineering. Overall, this doctoral project is founded on the hypothesis that smooth muscle cell hyperplasia, as an important causative factor for vascular restenosis following endovascular stent deployment, is triggered by the various effects of stent strut contact on the vessel wall including contact forces and material biocompatibility. In this program, a dynamic in vitro model of a stented blood vessel aimed at evaluating the effect of stent strut material selection, and surface coating on smooth muscle cell response was developed. The in vitro stented artery model was validated through the proliferation of VSMC in contact with stent struts. Additionally, it was demonstrated that, with respect to known biocompatible materials such as Nitinol and 316L stainless steel, DNA synthesis and alpha-actin expression, as indicators of VSMC phenotype, are independent of stent material composition. Furthermore, hydroxyapatite was shown to be a biocompatible stent surface coating with acceptable post-strain integrity. This coating was shown in a feasibility study to be capable of serving as a favorable drug delivery platform able to reliably deliver locally therapeutic doses of bisphosphonates, such as alendronate, to control VSMC proliferation in an in vitro model of a stented blood vessel. This stent coating/drug combination may be effective for reducing restenosis as a result of VSMC hyperplasia in vivo.

  3. Renal Artery Stent Outcomes

    Science.gov (United States)

    Murphy, Timothy P.; Cooper, Christopher J.; Matsumoto, Alan H.; Cutlip, Donald E.; Pencina, Karol M.; Jamerson, Kenneth; Tuttle, Katherine R.; Shapiro, Joseph I.; D’Agostino, Ralph; Massaro, Joseph; Henrich, William; Dworkin, Lance D.

    2016-01-01

    BACKGROUND Multiple randomized clinical trials comparing renal artery stent placement plus medical therapy with medical therapy alone have not shown any benefit of stent placement. However, debate continues whether patients with extreme pressure gradients, stenosis severity, or baseline blood pressure benefit from stent revascularization. OBJECTIVES The study sought to test the hypothesis that pressure gradients, stenosis severity, and/or baseline blood pressure affects outcomes after renal artery stent placement. METHODS Using data from 947 patients with a history of hypertension or chronic kidney disease from the largest randomized trial of renal artery stent placement, the CORAL (Cardiovascular Outcomes in Renal Atherosclerotic Lesions) study, we performed exploratory analyses to determine if subsets of patients experienced better outcomes after stent placement than the overall cohort. We examined baseline stenosis severity, systolic blood pressure, and translesion pressure gradient (peak systolic and mean) and performed interaction tests and Cox proportional hazards analyses for the occurrence of the primary endpoint through all follow-up, to examine the effect of these variables on outcomes by treatment group. RESULTS There were no statistically significant differences in outcomes based on the examined variables nor were there any consistent nonsignificant trends. CONCLUSIONS Based on data from the CORAL randomized trial, there is no evidence of a significant treatment effect of the renal artery stent procedure compared with medical therapy alone based on stenosis severity, level of systolic blood pressure elevation, or according to the magnitude of the transstenotic pressure gradient. (Benefits of Medical Therapy Plus Stenting for Renal Atherosclerotic Lesions [CORAL]; NCT00081731) PMID:26653621

  4. Tratamento endovascular de aneurisma de tronco braquiocefálico em paciente com síndrome de Ehlers-Danlos tipo IV

    Directory of Open Access Journals (Sweden)

    Sergio Quilici Belczak

    Full Text Available Resumo A síndrome de Ehlers-Danlos é uma doença genética que acarreta alteração na síntese de colágeno, causando extrema fragilidade do tecido conjuntivo. Tal fragilidade predispõe a uma série de doenças vasculares, como dissecções, aneurismas e pseudoaneurismas. Os autores relatam o histórico de um indivíduo de 19 anos com aneurisma de tronco braquiocefálico que foi submetido ao tratamento endovascular com implante de stents revestidos. O caso evoluiu com complicação do sítio de punção, que também foi tratada em caráter de emergência pela técnica endovascular com o implante de stent revestido.

  5. Use of platelet rich fibrin in a fenestration defect around an implant

    Directory of Open Access Journals (Sweden)

    R Vijayalakshmi

    2012-01-01

    Full Text Available Guided bone regeneration (GBR in implant therapy is especially useful for implant placement with dehiscence defects or fenestration defects. In alveolar ridges with marked facial/buccal depressions or in knifeedge alveolar crests, the position and direction of fixture placement is restricted. Improvement of alveolar ridge morphology becomes possible with GBR. This article describes a case in which the fenestration defect around an implant was treated by the application of platelet rich fibrin, a second generation platelet concentrate along with bone graft, and guided tissue regeneration membrane.

  6. Rheumatic aortic regurgitation in a patient with large congenital fenestrations in all three leaflets.

    Science.gov (United States)

    Jodati, Ahmadreza; Kazemi, Babak; Safaei, Naser

    2014-01-01

    Fenestrations of the aortic valve rarely produce significant valvular regurgitation. These are typically described as incidental findings with little clinical significance because they generally lie above their closing edges. Rarely however, when unusually large or multiple, they can lead to massive aortic regurgitation (AR), mostly in patients with chronic hypertension and/or aortic annular dilation. We operated a 52 year old normotensive male with chronic rheumatic AR and found large fenestrations in all three aortic cusps, hardly ever reported in rheumatic valvular involvement in the literature.

  7. Dual Arterial Access for Stenting of Aortic Coarctation in Patients with Near-Total Descending Aortic Interruption.

    Science.gov (United States)

    Hamid, Tahir; Jamallulail, Syed Ibrahim; Clarke, Bernard; Mahadevan, Vaikom S

    2015-12-01

    Endovascular stenting is a recognized treatment strategy for the treatment of coarctation of aorta (COA) in adults. The aortic coarctation is usually crossed retrogradely from the descending aorta via the femoral approach. We report three patients who had near-total descending aortic interruption and underwent successful stenting of severe COA using a combined radial/brachial and femoral approach due to difficulty in crossing the lesion retrogradely via a femoral approach. There were no procedural complications and no adverse events during 6 months of follow-up.

  8. Tracheobronchial stents in children.

    Science.gov (United States)

    Antón-Pacheco, Juan L

    2016-06-01

    Tracheobronchial obstruction is infrequent in children and still remains a challenging matter of concern. Management alternatives vary from conservative treatment to complex surgical techniques or endoscopic interventional procedures. Airway stenting in children is relatively recent and follows the trail of the experience in adult patients. Nevertheless, there are basic differences between both age groups like the benign nature of most obstructions and the small size of the pediatric airway. These specific features raise the issues of the precise role of tracheobronchial stenting in children and the selection of the most adequate device. Stents fall into four main categories according to the material they are made of: metallic, plastic, hybrid, and biodegradable. Each type has its own advantages and drawbacks so the ideal stent is not yet available. Despite increasing experience with stenting, definite clinical criteria for their use in children are yet to be established. Even so, there seems to be a basic general agreement that stents may play a role in particular clinical settings in which there are no other therapeutic options. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Drug-eluting stents to prevent stent thrombosis and restenosis.

    Science.gov (United States)

    Im, Eui; Hong, Myeong-Ki

    2016-01-01

    Although first-generation drug-eluting stents (DES) have significantly reduced the risk of in-stent restenosis, they have also increased the long-term risk of stent thrombosis. This safety concern directly triggered the development of new generation DES, with innovations in stent platforms, polymers, and anti-proliferative drugs. Stent platform materials have evolved from stainless steel to cobalt or platinum-chromium alloys with an improved strut design. Drug-carrying polymers have become biocompatible or biodegradable and even polymer-free DES were introduced. New limus-family drugs (such as everolimus, zotarolimus or biolimus) were adopted to enhance stent performances. As a result, these new DES demonstrated superior vascular healing responses on intracoronary imaging studies and lower stent thrombotic events in actual patients. Recently, fully-bioresorbable stents (scaffolds) have been introduced, and expanding their applications. In this article, the important concepts and clinical results of new generation DES and bioresorbable scaffolds are described.

  10. Stent Fracture after Everolimus-Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Ali S. Almasood

    2011-01-01

    Full Text Available Compared with bare-metal stents, drug-eluting stents (DES have greatly reduced the risk of in-stent restenosis (ISR by inhibiting neointimal growth. Nevertheless, DES are still prone to device failure, which may lead to cardiac events. Recently, stent fracture (SF has emerged as a potential mechanism of DES failure that is associated with ISR. Stent fracture is strongly related to stent type, and prior reports suggest that deployment of sirolimus eluting stents (SES may be associated with a higher risk of SF compared to other DES. Everolimus eluting stents (EESs represent a new generation of DES with promising results. The occurrence of SF with EES has not been well established. The present paper describes two cases of EES fracture associated with ISR.

  11. Nanomaterial coatings applied on stent surfaces.

    Science.gov (United States)

    Bagheri, Mahsa; Mohammadi, Marzieh; Steele, Terry Wj; Ramezani, Mohammad

    2016-05-01

    The advent of percutaneous coronary intervention and intravascular stents has revolutionized the field of interventional cardiology. Nonetheless, in-stent restenosis, inflammation and late-stent thrombosis are the major obstacles with currently available stents. In order to enhance the hemocompatibility of stents, advances in the field of nanotechnology allow novel designs of nanoparticles and biomaterials toward localized drug/gene carriers or stent scaffolds. The current review focuses on promising polymers used in the fabrication of newer generations of stents with a short synopsis on atherosclerosis and current commercialized stents, nanotechnology's impact on stent development and recent advancements in stent biomaterials is discussed in context.

  12. Cobalt chromium stents versus stainless steel stents in diabetic patients

    Directory of Open Access Journals (Sweden)

    Mahmoud Ahmed Tantawy

    2014-03-01

    Conclusions: We concluded that no significant statistical difference was found between the two stents (cobalt-chromium alloy bare metal stent versus conventional bare metal stainless steel stent in diabetic patients regarding (initial procedural success, in-hospital complications, the incidence of ISR at follow up, event-free survival at follow up.

  13. Critical evaluation of stents in the peripheral arterial disease of the superficial femoral artery – focus on the paclitaxel eluting stent

    Directory of Open Access Journals (Sweden)

    Litsky J

    2014-05-01

    Full Text Available Jason Litsky,1 Arijit Chanda,2 Erik Stilp,1 Alexandra Lansky,1 Carlos Mena11Section of Cardiovascular Medicine, Department of Internal Medicine, Yale University School of Medicine, New Haven, CT, USA; 2Section of Cardiology, Department of Internal Medicine, Bridgeport Hospital, Bridgeport, CT, USAAbstract: The endovascular management of obstructive disease of the superficial femoral artery (SFA is challenging due to unique anatomical and biomechanical forces. Obstructive lesions of the SFA make up the largest proportion of lesions leading to symptomatic peripheral arterial disease. Accordingly, endovascular treatment of SFA disease is becoming increasingly common and, in many cases, is the preferred initial therapy. The use of self-expanding nitinol stents have proven superior to percutaneous transluminal balloon angioplasty in the treatment of intermediate length SFA stenosis. However, achieving durable results, as well as attaining adequate therapy for long occlusions typically seen in clinical practice, remains problematic. Newer technologies, such as paclitaxel eluting stents, seem promising in improving outcomes.Keywords: Zilver PTX, self-expanding stent, atherosclerotic disease, superficial femoral artery

  14. [The treatment of abdominal aortic aneurysms by use of endovascular prosthesis and classic vascular prosthesis].

    Science.gov (United States)

    Pupka, Artur; Szyber, Przemysław P; Janczak, Dariusz; Pawłowski, Stanisław; Szyber, Piotr

    2006-01-01

    The abdominal aortic aneurysm is a dilatation of infrarenal part of aorta. Its ethiology is still unknown. An infection and congenital disorders of conjunctive tissue are regarded as the main risc factors. Other factors could be a perimural thrombus and elastin and colagen degradation. It's not proved that atheromatosis is a risc factor. The disease concerns mainly the old males. Not treated aneurysm grows until rupture. The aneurysms are usually asympthomatic. Majority of them are found incidentally. Ultrasonography and computed tomography are used to extended diagnosis. The open surgery or endovascular surgery are only possible ways of treatment. The aneurysm with diameter over 55 milimeters, sympthomatic or rupted is an indication for surgery. The aim of the open surgery is implantation of the vascular prosthesis into retroperitoneal space. Endovascular method consist in placement of stent-graft in the lumen of aneurysm through small incision in a peripherial vessel. Stent-graft consists of metal chassis covered by classic vascular prosthesis. This method still requires the long-term assessment.

  15. Aortoenteric Fistula as a Complication of Open Reconstruction and Endovascular Repair of Abdominal Aorta

    Directory of Open Access Journals (Sweden)

    Marek Tagowski

    2014-01-01

    Full Text Available The paper intends to present