WorldWideScience

Sample records for fenestrated endovascular repair

  1. Outcomes of fenestrated and branched endovascular repair of complex abdominal and thoracoabdominal aortic aneurysms.

    Science.gov (United States)

    Schanzer, Andres; Simons, Jessica P; Flahive, Julie; Durgin, Jonathan; Aiello, Francesco A; Doucet, Danielle; Steppacher, Robert; Messina, Louis M

    2017-09-01

    More than 80% of infrarenal aortic aneurysms are treated by endovascular repair. However, adoption of fenestrated and branched endovascular repair for complex aortic aneurysms has been limited, despite high morbidity and mortality associated with open repair. There are few published reports of consecutive outcomes, inclusive of all fenestrated and branched endovascular repairs, starting from the inception of a complex aortic aneurysm program. Therefore, we examined a single center's consecutive experience of fenestrated and branched endovascular repair of complex aortic aneurysms. This is a single-center, prospective, observational cohort study evaluating 30-day and 1-year outcomes in all consecutive patients who underwent fenestrated and branched endovascular repair of complex aortic aneurysms (definition: requiring one or more fenestrations or branches). Data were collected prospectively through an Institutional Review Board-approved registry and a physician-sponsored investigational device exemption clinical trial (G130210). We performed 100 consecutive complex endovascular aortic aneurysm repairs (November 2010 to March 2016) using 58 (58%) commercially manufactured custom-made devices and 42 (42%) physician-modified devices to treat 4 (4%) common iliac, 42 (42%) juxtarenal, 18 (18%) pararenal, and 36 (36%) thoracoabdominal aneurysms (type I, n = 1; type II, n = 4; type III, n = 12; type IV, n = 18; arch, n = 1). The repairs included 309 fenestrations, branches, and scallops (average of 3.1 branch arteries/case). All patients had 30-day follow-up for 30-day event rates: three (3%) deaths; six (6%) target artery occlusions; five (5%) progressions to dialysis; eight (8%) access complications; one (1%) paraparesis; one (1%) bowel ischemia; and no instances of myocardial infarction, paralysis, or stroke. Of 10 type I or type III endoleaks, 8 resolved (7 with secondary intervention, 1 without intervention). Mean follow-up time was 563 days (interquartile range

  2. Fenestrated endovascular aortic aneurysm repair using physician-modified endovascular grafts versus company-manufactured devices.

    Science.gov (United States)

    Dossabhoy, Shernaz S; Simons, Jessica P; Flahive, Julie M; Aiello, Francesco A; Sheth, Parth; Arous, Edward J; Messina, Louis M; Schanzer, Andres

    2017-12-07

    Fenestrated endografts are customized, patient-specific endovascular devices with potential to reduce morbidity and mortality of complex aortic aneurysm repair. With approval from the U.S. Food and Drug Administration, our center began performing fenestrated endovascular aneurysm repair through a physician-sponsored investigational device exemption (IDE #G130210), using both physician-modified endografts (PMEGs) and company-manufactured devices (CMDs). Because these techniques are associated with specific advantages and disadvantages, we sought to investigate differences in outcomes between PMEG and CMD cases. A single-institution retrospective review of all fenestrated endovascular aneurysm repairs was performed. The cohort was analyzed by device type (PMEG or CMD) after matching of cases on the basis of (1) number of target vessels intended for treatment, (2) extent of aneurysm, (3) aneurysm diameter, (4) device configuration, and (5) date of operation. Outcomes of ruptures, common iliac artery aneurysms, and aortic arch aneurysms were excluded. Demographics, operative details, perioperative complications, length of stay, and reinterventions were compared. For patients with >1 year of follow-up time, survival, type I or type III endoleak rate, target artery patency, and reintervention rate were estimated using the Kaplan-Meier method. Between November 30, 2010, and July 30, 2016, 82 patients were identified and matched. The cohort included 41 PMEG and 41 CMD patients who underwent repair of 38 juxtarenal (PMEG, 17; CMD, 21; P = .38), 14 pararenal (PMEG, 6; CMD, 8; P = .56), and 30 thoracoabdominal type I to type IV (PMEG, 18; CMD, 12; P = .17) aneurysms. There were significant differences in presentation requiring urgent aneurysm repair (PMEG, 9; CMD, 0; P = .002), total fluoroscopy time (PMEG, 76 minutes; CMD, 61 minutes; P = .02), volume of contrast material used (PMEG, 88 mL; CMD, 70 mL; P = .02), in-operating room to out-of-operating room time

  3. Endovascular Repair of Thoracoabdominal and Arch Aneurysms in Patients with Connective Tissue Disease Using Branched and Fenestrated Devices.

    Science.gov (United States)

    Clough, Rachel E; Martin-Gonzalez, Teresa; Van Calster, Katrien; Hertault, Adrien; Spear, Rafaëlle; Azzaoui, Richard; Sobocinski, Jonathan; Haulon, Stéphan

    2017-10-01

    Prophylactic open surgery is the standard practice in patients with connective tissue and thoracoabdominal aortic aneurysm (TAAA) and aortic arch disease. Branched and fenestrated devices offer a less invasive alternative but there are concerns regarding the durability of the repair and the effect of the stent graft on the fragile aortic wall. The aim of this study is to evaluate mid-term outcomes of fenestrated and/or branched endografting in patients with connective tissue disease. All patients with connective tissue disease who underwent TAAA or arch aneurysm repair using a fenestrated and/or branched endograft in a single, high-volume center between 2004 and 2015 were included. Ruptured aneurysms and acute aortic dissections were excluded from this study, but not chronic aortic dissections. In total, 427 (403 pararenal and TAAAs, and 24 arch aneurysms) endovascular interventions were performed during the study period. Of these, 17 patients (4%) (16 TAAAs, 1 arch) had connective tissue disease. All patients were classified as unfit for open repair. The mean age was 51 ± 8 years. Thirteen patients with TAAA were treated with a fenestrated, 1 with a branched, and 2 with a combined fenestrated/branch device. A double inner branch device was used to treat the arch aneurysm. The technical success rate was 100% with no incidence of early mortality, spinal cord ischemia, stroke, or further dissection. Postoperative deterioration in renal function was seen in 3 patients (18.8%) and no hemodialysis was required. The mean follow-up was 3.4 years (0.3-7.4). Aneurysm sac shrinkage was seen in 35% of patients (6/17) and the sac diameter remained stable in 65% of patients (11/17). No sac or sealing zone enlargement was observed in any of the patients and there were no conversions to open repair. Reintervention was required in 1 patient at 2 years for bilateral renal artery occlusion (successful fibrinolysis). One type II endoleak (lumbar) is under surveillance and 1 type

  4. Survival affects decision making for fenestrated and branched endovascular aortic repair.

    Science.gov (United States)

    Beach, Jocelyn M; Rajeswaran, Jeevanantham; Parodi, F Ezequiel; Kuramochi, Yuki; Brier, Corey; Blackstone, Eugene; Eagleton, Matthew J

    2018-03-01

    Repair options for complex abdominal and thoracoabdominal aortic aneurysms (TAAAs) are evolving with increased experience and availability of less invasive endovascular techniques. Identifying risk factors for mortality after fenestrated and branched endovascular aortic repair (F/B-EVAR) could improve patient selection and facilitate decision making regarding who may benefit from prophylactic F/B-EVAR. We evaluated 1091 patients in a prospective investigational device exemption trial who underwent F/B-EVAR from August 2001 to June 2015 for complex aortic aneurysms (CAAs). Multivariable analysis of risk factors for death was performed using a nonproportional hazards model and a nonparametric analysis using random survival forest technology. Operative mortality after F/B-EVAR was low (3.7%), with high CAA-related survival at 30 day and 5 years (96.8% and 94.0%, respectively). All-cause 5-year survival, however, was 46.2% and older age, heart failure, chronic obstructive pulmonary disease, renal disease, anemia, and coagulation disorders were risk factors. Risk was highest for those undergoing type I/II TAAA repairs and those with larger aneurysms. Patients with multiple comorbidities and those undergoing type I or II TAAA repair are at greatest risk of mortality; however, in this high-risk population, F/B-EVAR offers greater survival compared with that reported for the natural history of untreated aneurysms. Operative and early mortality is lower than the best-reported open repair outcomes, even in this high-risk population, suggesting a potential benefit in extending the use of F/B-EVAR to low-to-average risk CAA patients. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  5. Total Endovascular Aortic Repair in a Patient with Marfan Syndrome.

    Science.gov (United States)

    Amako, Mau; Spear, Rafaëlle; Clough, Rachel E; Hertault, Adrien; Azzaoui, Richard; Martin-Gonzalez, Teresa; Sobocinski, Jonathan; Haulon, Stéphan

    2017-02-01

    The aim of this study is to describe a total endovascular aortic repair with branched and fenestrated endografts in a young patient with Marfan syndrome and a chronic aortic dissection. Open surgery is the gold standard to treat aortic dissections in patients with aortic disease and Marfan syndrome. In 2000, a 38-year-old man with Marfan syndrome underwent open ascending aorta repair for an acute type A aortic dissection. One year later, a redo sternotomy was performed for aortic valve replacement. In 2013, the patient presented with endocarditis and pulmonary infection, which necessitated tracheostomy and temporary dialysis. In 2014, the first stage of the endovascular repair was performed using an inner branched endograft to exclude a 77-mm distal arch and descending thoracic aortic aneurysm. In 2015, a 63-mm thoracoabdominal aortic aneurysm was excluded by implantation of a 4-fenestrated endograft. Follow-up after both endovascular repairs was uneventful. Total aortic endovascular repair was successfully performed to treat a patient with arch and thoraco-abdominal aortic aneurysm associated with chronic aortic dissection and Marfan syndrome. The postoperative images confirmed patency of the endograft and its branches, and complete exclusion of the aortic false lumen. Endovascular repair is a treatment option in patients with connective tissue disease who are not candidates for open surgery. Long-term follow-up is required to confirm these favorable early outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Changes in Renal Anatomy After Fenestrated Endovascular Aneurysm Repair.

    Science.gov (United States)

    Maurel, B; Lounes, Y; Amako, M; Fabre, D; Hertault, A; Sobocinski, J; Spear, R; Azzaoui, R; Mastracci, T M; Haulon, S

    2017-01-01

    To assess short- and long-term movement of renal arteries after fenestrated endovascular aortic repair (FEVAR). Consecutive patients who underwent FEVAR at one institution with a custom-made device designed with fenestrations for the superior mesenteric (SMA) and renal arteries, a millimetric computed tomography angiography (CTA), and a minimum of 2 years' follow-up were included. Angulation between renal artery trunk and aorta, clock position of the origin of the renal arteries, distance between renal arteries and SMA, and target vessel occlusion were retrospectively collected and compared between the pre-operative, post-operative (12 months) CTA. From October 2004 to January 2014, 100 patients met the inclusion criteria and 86% of imaging was available for accurate analysis. Median follow-up was 27.3 months (22.7-50.1). There were no renal occlusions. A significant change was found in the value of renal trunk angulation of both renal arteries on post-operative compared with pre-operative CTA (17° difference upward [7.5-29], p renal clock positions (7.5° of change equivalent to 15 min of renal ostial movement): significant anterior change was found between post-operative and pre-operative CTA (15 min [0-30], p = .03 on the left and 15 min [15-30], p renal and SMA ostia (difference of 1.65 mm [1-2.5], p = .63). The renal arteries demonstrate tolerance to permanent changes in angulation after FEVAR of approximately 17° upward trunk movement and of 15-30 min ostial movement without adverse consequences on patency after a median of more than 2 years' follow-up. The distance between the target vessels remained stable over time. These results may suggest accommodation to sizing errors and thus a compliance with off the shelf devices in favourable anatomies. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  7. Influence of Anatomic Angulations in Chimney and Fenestrated Endovascular Aneurysm Repair.

    Science.gov (United States)

    Caradu, Caroline; Bérard, Xavier; Midy, Dominique; Ducasse, Eric

    2017-08-01

    The lack of widespread availability of Fenestrated endovascular aneurysm repair (F-EVAR) encouraged alternative strategies. Hence, Chimney graft (CG)-EVAR spread when costs, manufacturing delays, or anatomy preclude F-EVAR. Our objective is to evaluate CG- and F-EVAR outcomes depending on the angulation of target renal arteries and hostility of iliac accesses in order to determine the potential impact of a choice made between both techniques on the basis of preoperative anatomic criteria. Consecutive patients treated by CG-EVAR or F-EVAR, from January 2010 to January 2015, were considered for inclusion. Anatomic parameters were defined by preoperative computed tomography angiography. A subgroup analysis was performed depending on renal arteries' angulation (cut-off: -30°) and iliac arteries' hostility (cut-off: diameter renal artery was shorter in the CG group (11.7 ± 6.2 mm vs. 14.1 ± 5.9 mm, P = 0.06). Longitudinal angulation of the right renal artery was not statistically different between both groups, while the left renal artery presented with a significantly more downward angulation in the CG group (-32.0 ± 15.3 vs. -19.0 ± 19.6, P = 0.003). There were significantly more grade 3 iliac tortuosity indexes for CG-EVAR (P = 0.03) with significantly smaller external iliac diameters (7.8 ± 1.7 vs. 8.8 ± 1.6 mm, P = 0.0009). There was 1 renal artery early occlusion in the renal artery angulation and diameter, iliac artery hostility, and aortic neck length among other parameters may help the surgeon make a decision toward the endovascular strategy that seems best suited for each specific patient. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

    Science.gov (United States)

    Spear, Rafaelle; Sobocinski, Jonathan; Hertault, Adrien; Delloye, Matthieu; Azzauiu, Richard; Fabre, Dominique; Haulon, Stéphan

    2018-04-01

    To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is

  9. Advanced endografting techniques: snorkels, chimneys, periscopes, fenestrations, and branched endografts.

    Science.gov (United States)

    Kansagra, Kartik; Kang, Joseph; Taon, Matthew-Czar; Ganguli, Suvranu; Gandhi, Ripal; Vatakencherry, George; Lam, Cuong

    2018-04-01

    The anatomy of aortic aneurysms from the proximal neck to the access vessels may create technical challenges for endovascular repair. Upwards of 30% of patients with abdominal aortic aneurysms (AAA) have unsuitable proximal neck morphology for endovascular repair. Anatomies considered unsuitable for conventional infrarenal stent grafting include short or absent necks, angulated necks, conical necks, or large necks exceeding size availability for current stent grafts. A number of advanced endovascular techniques and devices have been developed to circumvent these challenges, each with unique advantages and disadvantages. These include snorkeling procedures such as chimneys, periscopes, and sandwich techniques; "homemade" or "back-table" fenestrated endografts as well as manufactured, customized fenestrated endografts; and more recently, physician modified branched devices. Furthermore, new devices in the pipeline under investigation, such as "off-the-shelf" fenestrated stent grafts, branched stent grafts, lower profile devices, and novel sealing designs, have the potential of solving many of the aforementioned problems. The treatment of aortic aneurysms continues to evolve, further expanding the population of patients that can be treated with an endovascular approach. As the technology grows so do the number of challenging aortic anatomies that endovascular specialists take on, further pushing the envelope in the arena of aortic repair.

  10. Endovascular Aortic Aneurysm Repair with Chimney and Snorkel Grafts: Indications, Techniques and Results

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rakesh P., E-mail: rpatel9@nhs.net [Northwick Park Hospital, Department of Vascular Radiology (United Kingdom); Katsargyris, Athanasios, E-mail: kthanassos@yahoo.com; Verhoeven, Eric L. G., E-mail: Eric.Verhoeven@klinikum-nuernberg.de [Klinikum Nuernberg, Department of Vascular and Endovascular Surgery (Germany); Adam, Donald J., E-mail: donald.adam@tiscali.co.uk [Heartlands Hospital, Department of Vascular Surgery (United Kingdom); Hardman, John A., E-mail: johnhardman@doctors.org.uk [Royal United Hospital Bath, Department of Vascular Radiology (United Kingdom)

    2013-12-15

    The chimney technique in endovascular aortic aneurysm repair (Ch-EVAR) involves placement of a stent or stent-graft parallel to the main aortic stent-graft to extend the proximal or distal sealing zone while maintaining side branch patency. Ch-EVAR can facilitate endovascular repair of juxtarenal and aortic arch pathology using available standard aortic stent-grafts, therefore, eliminating the manufacturing delays required for customised fenestrated and branched stent-grafts. Several case series have demonstrated the feasibility of Ch-EVAR both in acute and elective cases with good early results. This review discusses indications, technique, and the current available clinical data on Ch-EVAR.

  11. Stepwise Total Aortic Repairs With Fenestrated Endografts in a Patient With Loeys-Dietz Syndrome.

    Science.gov (United States)

    Hashizume, Kenichi; Shimizu, Hideyuki; Honda, Masanori; Inoue, Shinya; Takaki, Hidenobu; Hayashi, Kanako; Kaneyama, Hiroaki

    2017-07-01

    Loeys-Dietz syndrome (LDS) is a rare connective tissue disorder (CTD) caused by mutations in the gene encoding transforming growth factor-β receptors Ⅰ and Ⅱ. Patients with LDS manifest spontaneous aneurysms and dissections of the aorta and peripheral artery. We report a successful treatment with a hybrid endovascular repair for a rapidly expanding thoracoabdominal aneurysm in a 41-year-old woman affected by LDS. To overcome the difficulties of anatomical and surgical repair, we applied an original strategy using surgeon-modified fenestrated endografts. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Aneurisma de la aorta abdominal: Tratamiento endovascular con una endoprótesis fenestrada Abdominal aortic aneurysm: Endovascular treatment with fenestrated endoprothesis

    Directory of Open Access Journals (Sweden)

    Román Rostagno

    2008-12-01

    Full Text Available El tratamiento endovascular de los aneurismas de aorta abdominal es una alternativa a la cirugía abierta para pacientes de alto riesgo. Consiste en la exclusión del saco aneurismático mediante la interposición de una endoprótesis colocada por vía femoral. El tratamiento endovascular no puede ser utilizado en todos los pacientes. Una limitación frecuente la constituye el nacimiento de una arteria visceral desde el saco aneurismático. Para contrarrestar esta limitación recientemente se han desarrollado endoprótesis fenestradas que presentan orificios que se corresponden con el nacimiento de las arterias involucradas en el aneurisma evitando su oclusión, permitiendo de esta manera el tratamiento endovascular. En esta comunicación se presenta un caso de tratamiento endovascular de un aneurisma de aorta abdominal mediante la colocación de una endoprótesis fenestrada en un paciente cuya arteria renal izquierda nacía directamente del saco aneurismático.Endovascular treatment of the abdominal aortic aneurysm is consider an alternative to open surgery for high risk patients. Its goal is to exclude the aneurysm from the circulation by using an endoprothesis introduced from a femoral approach. Patients must be strictly selected to avoid possible complications. The most frequent limitation is related to anatomic contraindications such as visceral arteries involved in the aneurysm. Fenestrated endograft have been recently developed to allow endovascular treatment when anatomic features contraindicate classic endovascular procedures. Fenestrated endograft have holes that match with the origin of the visceral arteries maintaining its potency. In this paper we report the endovascular treatment of an abdominal aortic aneurysm by using a fenestrated endoprothesis in a patient whose left renal artery is originated from the aneurysm.

  13. Anatomic changes of target vessels after fenestrated and branched aortic aneurysm repair.

    Science.gov (United States)

    Kalder, J; Keschenau, P; Tamm, M; Jalaie, H; Jacobs, M J; Greiner, A

    2014-04-01

    Objective of this study was to evaluate the anatomic changes of the stented target vessels after endovascular repair of complex aortic aneurysms. Between July 2011 and December 2013, 53 aortic aneurysms were treated in our department with fenestrated and branched stent-graft devices. Forty-two of these patients were pre- and postoperatively scanned with a high resolution computer tomography (CT) (Cook Zenith® fenestrated or branched, Australia Pty. Ltd., Brisbane, Australia: N.=19; AnacondaTM fenestrated, Vascutek, Glasgow, Scotland, UK: N.=23). The other 11 out of the 53 patients did not receive a CT scan, because of a pre-existing renal failure. In the CT scans we retrospectively evaluated the anatomic vessel deviation at the origin of the target vessel and the vessel shift distal to the stent. For the first measurement the CT scans were loaded into OsiriX MD®, and the pre- and postoperative angles of the target vessels were measured and subtracted. For matching, the CT-scans were normalized at vertebral body lumbar 2. The second measured angle was the maximal measured angle distal to the target vessel stent-graft. Altogether, 113 target vessels were stented (celiac trunk [CT] 15, superior mesenteric arteries [SMA] 26, renal arteries [RA] 72), with 97 balloon-expandable PTFE stents: 90 Atrium V12 (Maquet Getinge group, Hudson, NH, USA), 7 BeGrafts (Bentley InnoMed, Hechingen, Germany) and 16 self-expandable fluency PTFE stents (Bard, Karlsruhe, Germany). The mean anatomic deviation at the target vessel origin was 28±17.3 and the mean vessel shift distal to the stent was 36.3±18.8. There were no significant differences between the main device and the target vessel stent types. Fenestrated and branched stent-graft solutions for aortic aneurysm repair induce changes of the target vessel anatomy. We did not observe significant differences between the several devices.

  14. 3D Stereoscopic Visualization of Fenestrated Stent Grafts

    International Nuclear Information System (INIS)

    Sun Zhonghua; Squelch, Andrew; Bartlett, Andrew; Cunningham, Kylie; Lawrence-Brown, Michael

    2009-01-01

    The purpose of this study was to present a technique of stereoscopic visualization in the evaluation of patients with abdominal aortic aneurysm treated with fenestrated stent grafts compared with conventional 2D visualizations. Two patients with abdominal aortic aneurysm undergoing fenestrated stent grafting were selected for inclusion in the study. Conventional 2D views including axial, multiplanar reformation, maximum-intensity projection, and volume rendering and 3D stereoscopic visualizations were assessed by two experienced reviewers independently with regard to the treatment outcomes of fenestrated repair. Interobserver agreement was assessed with Kendall's W statistic. Multiplanar reformation and maximum-intensity projection visualizations were scored the highest in the evaluation of parameters related to the fenestrated stent grafting, while 3D stereoscopic visualization was scored as valuable in the evaluation of appearance (any distortions) of the fenestrated stent. Volume rendering was found to play a limited role in the follow-up of fenestrated stent grafting. 3D stereoscopic visualization adds additional information that assists endovascular specialists to identify any distortions of the fenestrated stents when compared with 2D visualizations.

  15. Infolding of fenestrated endovascular stent graft.

    Science.gov (United States)

    Zelt, Jason G E; Jetty, Prasad; Hadziomerovic, Adnan; Nagpal, Sudhir

    2017-09-01

    We report a case of infolding of a fenestrated stent graft involving the visceral vessel segment after a juxtarenal abdominal aorta aneurysm repair. The patient remains free of any significant endoleak, and the aortic sac has shown regression. The patient remains asymptomatic, with no abdominal pain, with normal renal function, and without ischemic limb complications. We hypothesize that significant graft oversizing (20%-30%) with asymmetric engineering of the diameter-reducing ties may have contributed to the infolding. Because of the patient's asymptomatic nature and general medical comorbidities, further intervention was deemed inappropriate as the aneurysmal sac is regressing despite the infolding.

  16. Extra-anatomic endovascular repair of an abdominal aortic aneurysm with a horseshoe kidney supplied by the aneurysmal aorta.

    Science.gov (United States)

    Rey, Jorge; Golpanian, Samuel; Yang, Jane K; Moreno, Enrique; Velazquez, Omaida C; Goldstein, Lee J; Chahwala, Veer

    2015-07-01

    Abdominal aortic aneurysm complicated by a horseshoe kidney (HSK, fused kidney) represents a unique challenge for repair. Renal arteries arising from the aneurysmal aorta can further complicate intervention. Reports exist describing the repair of these complex anatomies using fenestrated endografts, hybrid open repairs (debranching), and open aneurysmorrhaphy with preservation of renal circulation. We describe an extra-anatomic, fully endovascular repair of an abdominal aortic aneurysm with a HSK partially supplied by a renal artery arising from the aneurysm. We successfully applied aortouni-iliac endografting, femorofemoral bypass, and retrograde renal artery perfusion via the contralateral femoral artery to exclude the abdominal aortic aneurysm and preserve circulation to the HSK. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Dutch experience with the fenestrated Anaconda endograft for short-neck infrarenal and juxtarenal abdominal aortic aneurysm repair.

    Science.gov (United States)

    Dijkstra, Martijn L; Tielliu, Ignace F J; Meerwaldt, Robbert; Pierie, Maurice; van Brussel, Jerome; Schurink, Geert Willem H; Lardenoye, Jan-Willem; Zeebregts, Clark J

    2014-08-01

    In the past decennium, the management of short-neck infrarenal and juxtarenal aortic aneurysms with fenestrated endovascular aneurysm repair (FEVAR) has been shown to be successful, with good early and midterm results. Recently, a new fenestrated device, the fenestrated Anaconda (Vascutek, Renfrewshire, Scotland), was introduced. The aim of this study was to present the current Dutch experience with this device. A prospectively held database of patients treated with the fenestrated Anaconda endograft was analyzed. Decision to treat was based on current international guidelines. Indications for FEVAR included an abdominal aortic aneurysm (AAA) with unsuitable neck anatomy for EVAR. Planning was performed on computed tomography angiography images using a three-dimensional workstation. Between May 2011 and September 2013, 25 patients were treated in eight institutions for juxtarenal (n = 23) and short-neck AAA (n = 2). Median AAA size was 61 mm (59-68.5 mm). All procedures except one were performed with bifurcated devices. A total of 56 fenestrations were incorporated, and 53 (94.6%) were successfully cannulated and stented. One patient died of bowel ischemia caused by occlusion of the superior mesenteric artery. On completion angiography, three type I endoleaks and seven type II endoleaks were observed. At 1 month of follow-up, all endoleaks had spontaneously resolved. Median follow-up was 11 months (range, 1-29 months). There were no aneurysm ruptures or aneurysm-related deaths and no reinterventions to date. Primary patency at 1 month of cannulated and stented target vessels was 96%. Initial and short-term results of FEVAR using the fenestrated Anaconda endograft are promising, with acceptable technical success and short-term complication rates. Growing experience and long-term results are needed to support these findings. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  18. 3D printed abdominal aortic aneurysm phantom for image guided surgical planning with a patient specific fenestrated endovascular graft system

    Science.gov (United States)

    Meess, Karen M.; Izzo, Richard L.; Dryjski, Maciej L.; Curl, Richard E.; Harris, Linda M.; Springer, Michael; Siddiqui, Adnan H.; Rudin, Stephen; Ionita, Ciprian N.

    2017-03-01

    Following new trends in precision medicine, Juxatarenal Abdominal Aortic Aneurysm (JAAA) treatment has been enabled by using patient-specific fenestrated endovascular grafts. The X-ray guided procedure requires precise orientation of multiple modular endografts within the arteries confirmed via radiopaque markers. Patient-specific 3D printed phantoms could familiarize physicians with complex procedures and new devices in a risk-free simulation environment to avoid periprocedural complications and improve training. Using the Vascular Modeling Toolkit (VMTK), 3D Data from a CTA imaging of a patient scheduled for Fenestrated EndoVascular Aortic Repair (FEVAR) was segmented to isolate the aortic lumen, thrombus, and calcifications. A stereolithographic mesh (STL) was generated and then modified in Autodesk MeshMixer for fabrication via a Stratasys Eden 260 printer in a flexible photopolymer to simulate arterial compliance. Fluoroscopic guided simulation of the patient-specific FEVAR procedure was performed by interventionists using all demonstration endografts and accessory devices. Analysis compared treatment strategy between the planned procedure, the simulation procedure, and the patient procedure using a derived scoring scheme. Results: With training on the patient-specific 3D printed AAA phantom, the clinical team optimized their procedural strategy. Anatomical landmarks and all devices were visible under x-ray during the simulation mimicking the clinical environment. The actual patient procedure went without complications. Conclusions: With advances in 3D printing, fabrication of patient specific AAA phantoms is possible. Simulation with 3D printed phantoms shows potential to inform clinical interventional procedures in addition to CTA diagnostic imaging.

  19. Anastomotic pseudoaneurysms after surgical reconstruction: Outcomes after endovascular repair of symptomatic versus asymptomatic patients

    International Nuclear Information System (INIS)

    Nolz, Richard; Gschwendtner, Manfred; Jülg, Gregor; Plank, Christina; Beitzke, Dietrich; Teufelsbauer, Harald; Wibmer, Andreas; Kretschmer, Georg; Lammer, Johannes

    2012-01-01

    Purpose: To compare perioperative and follow-up outcomes of symptomatic versus asymptomatic patients following endovascular repair of anastomotic pseudoaneurysms (APAs) of the abdominal aorta and iliac arteries. Methods: We retrospectively evaluated 17 patients (two women), with a mean age of 66.2 years (range 30–83 years). Endovascular treatment was performed in ten symptomatic, and seven asymptomatic patients electively. Data included technical success, perioperative (within 30 days) mortality and morbidity, as well as stent graft-related complications, reinterventions, and survival in follow-up. Results: Bifurcated (n = 13), aortomonoiliac (n = 3) endoprosthesis and one aortic cuff were implanted with a primary technical success rate of 100%. The overall in-hospital mortality and morbidity rate was 11.8% and 35.3%. The mean survival was 36.5 (range 0–111) months. There was a clear trend toward a lower overall survival within hospital and at one and three years for symptomatic patients compared to asymptomatic patients. (47.7 (CI: 0–138.8) versus 52.6 (CI: 28.5–76.8) months (p = 0.274)). During follow-up, late stent graft related complications were observed in six patients (35.3%) necessitating eight endovascular reinterventions. Additional three patients with primary fistulas between the APA and the intestine were treated by late surgical revision. Conclusion: Endovascular therapy of APAs represents a considerable alternative to open surgical repair. Short proximal anchoring zones still pose a risk for endoleaks and unintentional overstenting of side branches with commercially available devices, but this might be overcome by use of fenestrated and branched stent grafts in elective cases.

  20. JAG Tearing Technique with Radiofrequency Guide Wire for Aortic Fenestration in Thoracic Endovascular Aneurysm Repair

    International Nuclear Information System (INIS)

    Ricci, Carmelo; Ceccherini, Claudio; Leonini, Sara; Cini, Marco; Vigni, Francesco; Neri, Eugenio; Tucci, Enrico; Benvenuti, Antonio; Tommasino, Giulio; Sassi, Carlo

    2012-01-01

    An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.

  1. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z. [Dept. of Imaging and Applied Physics, Curtin Univ. of Tech., Perth, WA (Australia); Allen, Y.; Fitzsimmons, B.; Hartely, D. [Cook R and D, WA (Australia); Lawrence-Brown, M. [Dept. of Public Health, Curtin Univ. of Tech., Perth, WA (Australia)

    2007-06-15

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  2. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    International Nuclear Information System (INIS)

    Sun, Z.; Allen, Y.; Fitzsimmons, B.; Hartely, D.; Lawrence-Brown, M.

    2007-01-01

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  3. Preoperative Evaluation and Endovascular Procedure of Intraoperative Aneurysm Rupture During Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Zha, Bin-Shan, E-mail: binszha2013@163.com; Zhu, Hua-Gang, E-mail: huagzhu@yeah.net; Ye, Yu-Sheng, E-mail: yeyusheng@aliyun.com; Li, Yong-Sheng, E-mail: 872868848@qq.com; Zhang, Zhi-Gong, E-mail: zzgedward@sina.com; Xie, Wen-Tao, E-mail: 345344347@qq.com [The First Affiliated Hospital of Anhui Medical University, Department of Vascular Surgery (China)

    2017-03-15

    Thoracic aortic aneurysms are now routinely repaired with endovascular repair if anatomically feasible because of advantages in safety and recovery. However, intraoperative aneurysm rupture is a severe complication which may have an adverse effect on the outcome of treatment. Comprehensive preoperative assessment and considerate treatment are keys to success of endovascular aneurysm repair, especially during unexpected circumstances. Few cases have reported on intraoperative aortic rupture, which were successfully managed by endovascular treatment. Here, we present a rare case of an intraoperative aneurysm rupture during endovascular repair of thoracic aortic aneurysm with narrow neck and angulated aorta arch (coarctation-associated aneurysm), which was successfully treated using double access route approach and iliac limbs of infrarenal devices.Level of EvidenceLevel 5.

  4. Endovascular repair of blunt popliteal arterial injuries

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Shan; Zhang, Xiquan; Chen, Zhong; Zhu, Wei; Pan, Xiaolin [Dept. of nterventional Vascular, The 148th Hospital of Chinese People' s Liberation Army, Zibo (China); Dong, Peng; Sun, Yequan [Dept. of Medical Imaging, Weifang Medical University, Weifang (China); Qi, Deming [Dept. of Medical Imaging, Qilu Medical University, Zibo (China)

    2016-09-15

    To evaluate the feasibility and effectiveness of endovascular repair for blunt popliteal arterial injuries. A retrospective analysis of seven patients with clinical suspicion of popliteal arterial injuries that were confirmed by arteriography was performed from September 2009 to July 2014. Clinical data included demographics, mechanism of injury, type of injury, location of injury, concomitant injuries, time of endovascular procedures, time interval from trauma to blood flow restoration, instrument utilized, and follow-up. All patients were male (mean age of 35.9 ± 10.3 years). The type of lesion involved intimal injury (n = 1), partial transection (n = 2), complete transection (n = 2), arteriovenous fistula (n = 1), and pseudoaneurysm (n = 1). All patients underwent endovascular repair of blunt popliteal arterial injuries. Technical success rate was 100%. Intimal injury was treated with a bare-metal stent. Pseudoaneurysm and popliteal artery transections were treated with bare-metal stents. Arteriovenous fistula was treated with bare-metal stent and coils. No perioperative death and procedure-related complication occurred. The average follow-up was 20.9 ± 2.3 months (range 18–24 months). One patient underwent intra-arterial thrombolysis due to stent thrombosis at 18 months after the procedure. All limbs were salvaged. Stent migration, deformation, or fracture was not found during the follow-up. Endovascular repair seems to be a viable approach for patients with blunt popliteal arterial injuries, especially on an emergency basis. Endovascular repair may be effective in the short-term. Further studies are required to evaluate the long-term efficacy of endovascular repair.

  5. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua; Chaichana, Thanapong [Curtin University of Technology, Perth (Australia)

    2010-02-15

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.

  6. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    International Nuclear Information System (INIS)

    Sun, Zhonghua; Chaichana, Thanapong

    2010-01-01

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair

  7. Pros and Cons of 3D Image Fusion in Endovascular Aortic Repair: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Goudeketting, Seline R; Heinen, Stefan G H; Ünlü, Çağdaş; van den Heuvel, Daniel A F; de Vries, Jean-Paul P M; van Strijen, Marco J; Sailer, Anna M

    2017-08-01

    To systematically review and meta-analyze the added value of 3-dimensional (3D) image fusion technology in endovascular aortic repair for its potential to reduce contrast media volume, radiation dose, procedure time, and fluoroscopy time. Electronic databases were systematically searched for studies published between January 2010 and March 2016 that included a control group describing 3D fusion imaging in endovascular aortic procedures. Two independent reviewers assessed the methodological quality of the included studies and extracted data on iodinated contrast volume, radiation dose, procedure time, and fluoroscopy time. The contrast use for standard and complex endovascular aortic repairs (fenestrated, branched, and chimney) were pooled using a random-effects model; outcomes are reported as the mean difference with 95% confidence intervals (CIs). Seven studies, 5 retrospective and 2 prospective, involving 921 patients were selected for analysis. The methodological quality of the studies was moderate (median 17, range 15-18). The use of fusion imaging led to an estimated mean reduction in iodinated contrast of 40.1 mL (95% CI 16.4 to 63.7, p=0.002) for standard procedures and a mean 70.7 mL (95% CI 44.8 to 96.6, p<0.001) for complex repairs. Secondary outcome measures were not pooled because of potential bias in nonrandomized data, but radiation doses, procedure times, and fluoroscopy times were lower, although not always significantly, in the fusion group in 6 of the 7 studies. Compared with the control group, 3D fusion imaging is associated with a significant reduction in the volume of contrast employed for standard and complex endovascular aortic procedures, which can be particularly important in patients with renal failure. Radiation doses, procedure times, and fluoroscopy times were reduced when 3D fusion was used.

  8. Endovascular repair of para-anastomotic aortoiliac aneurysms.

    LENUS (Irish Health Repository)

    Tsang, Julian S

    2009-11-01

    The purpose of this study is to evaluate the use of endovascular stent grafts in the treatment of para-anastomotic aneurysms (PAAs) as an alternative to high-risk open surgical repair. We identified all patients with previous open aortic aneurysm repair who underwent infrarenal endovascular aneurysm repair (EVAR) at our institution from June 1998 to April 2007. Patient demographics, previous surgery, and operative complications were recorded. One hundred forty-eight patients underwent EVAR during the study period and 11 patients had previous aortic surgery. Of these 11 redo patients, the mean age was 62 years at initial surgery and 71 years at EVAR. All patients were male. Initial open repair was for rupture in five (45%) patients. The average time between initial and subsequent reintervention was 9 years. All patients were ASA Grade III or IV. Fifty-five percent of the PAAs involved the iliac arteries, 36% the abdominal aorta, and 9% were aortoiliac. Ten patients had endovascular stent-grafts inserted electively, and one patient presented with a contained leak. Aorto-uni-iliac stent-grafts were deployed in seven patients, and bifurcated stent-grafts in four patients. A 100% successful deployment rate was achieved. Perioperative mortality was not seen and one patient needed surgical reintervention to correct an endoleak. Endovascular repair of PAAs is safe and feasible. It is a suitable alternative and has probably now become the treatment of choice in the management of PAAs.

  9. Computed tomography-based anatomic characterization of proximal aortic dissection with consideration for endovascular candidacy.

    Science.gov (United States)

    Moon, Michael C; Greenberg, Roy K; Morales, Jose P; Martin, Zenia; Lu, Qingsheng; Dowdall, Joseph F; Hernandez, Adrian V

    2011-04-01

    Proximal aortic dissections are life-threatening conditions that require immediate surgical intervention to avert an untreated mortality rate that approaches 50% at 48 hours. Advances in computed tomography (CT) imaging techniques have permitted increased characterization of aortic dissection that are necessary to assess the design and applicability of new treatment paradigms. All patients presenting during a 2-year period with acute proximal aortic dissections who underwent CT scanning were reviewed in an effort to establish a detailed assessment of their aortic anatomy. Imaging studies were assessed in an effort to document the location of the primary proximal fenestration, the proximal and distal extent of the dissection, and numerous morphologic measurements pertaining to the aortic valve, root, and ascending aorta to determine the potential for an endovascular exclusion of the ascending aorta. During the study period, 162 patients presented with proximal aortic dissections. Digital high-resolution preoperative CT imaging was performed on 76 patients, and 59 scans (77%) were of adequate quality to allow assessment of anatomic suitability for treatment with an endograft. In all cases, the dissection plane was detectable, yet the primary intimal fenestration was identified in only 41% of the studies. Scans showed 24 patients (32%) appeared to be anatomically amenable to such a repair (absence of valvular involvement, appropriate length and diameter of proximal sealing regions, lack of need to occlude coronary vasculature). Of the 42 scans that were determined not to be favorable for endovascular repair, the most common exclusion finding was the absence of a proximal landing zone (n = 15; 36%). Appropriately protocoled CT imaging provides detailed anatomic information about the aortic root and ascending aorta, allowing the assessment of which dissections have proximal fenestrations that may be amenable to an endovascular repair. Copyright © 2011 Society for

  10. Identifying patients with AAA with the highest risk following endovascular repair.

    Science.gov (United States)

    Cadili, Ali; Turnbull, Robert; Hervas-Malo, Marilou; Ghosh, Sunita; Chyczij, Harold

    2012-08-01

    It has been demonstrated that endovascular repair of arterial disease results in reduced perioperative morbidity and mortality compared to open surgical repair. The rates of complications and need for reinterventions, however, have been found to be higher than that in open repair. The purpose of this study was to identify the predictors of endograft complications and mortality in patients undergoing endovascular abdominal aortic aneurysm (AAA) repair; specifically, our aim was to identify a subset of patients with AAA whose risk of periprocedure mortality was so high that they should not be offered endovascular repair. We undertook a prospective review of patients with AAA receiving endovascular therapy at a single institution. Collected variables included age, gender, date of procedure, indication for procedure, size of aneurysm (where applicable), type of endograft used, presence of rupture, American Society of Anesthesiologists (ASA) class, major medical comorbidities, type of anesthesia (general, epidural, or local), length of intensive care unit (ICU) stay, and length of hospital stay. These factors were correlated with the study outcomes (overall mortality, graft complications, morbidity, and reintervention) using univariate and multivariate logistic regression. A total of 199 patients underwent endovascular AAA repair during the study period. The ICU stay, again, was significantly correlated with the primary outcomes (death and graft complications). In addition, length of hospital stay greater than 3 days, also emerged as a statistically significant predictor of graft complications in this subgroup (P = .024). Survival analysis for patients with AAA revealed that age over 85 years and ICU stay were predictive of decreased survival. Statistical analysis for other subgroups of patients (inflammatory AAA or dissection) was not performed due to the small numbers in these subgroups. Patients with AAA greater than 85 years of age are at a greater risk of mortality

  11. Predictive factors for cerebrovascular accidents after thoracic endovascular aortic repair.

    Science.gov (United States)

    Mariscalco, Giovanni; Piffaretti, Gabriele; Tozzi, Matteo; Bacuzzi, Alessandro; Carrafiello, Giampaolo; Sala, Andrea; Castelli, Patrizio

    2009-12-01

    Cerebrovascular accidents are devastating and worrisome complications after thoracic endovascular aortic repair. The aim of this study was to determine cerebrovascular accident predictors after thoracic endovascular aortic repair. Between January 2001 and June 2008, 76 patients treated with thoracic endovascular aortic repair were prospectively enrolled. The study cohort included 61 men; mean age was 65.4 +/- 16.8 years. All patients underwent a specific neurologic assessment on an hourly basis postoperatively to detect neurologic deficits. Cerebrovascular accidents were diagnosed on the basis of physical examination, tomography scan or magnetic resonance imaging, or autopsy. Cerebrovascular accidents occurred in 8 (10.5%) patients, including 4 transient ischemic attack and 4 major strokes. Four cases were observed within the first 24-hours. Multivariable analysis revealed that anatomic incompleteness of the Willis circle (odds ratio [OR] 17.19, 95% confidence interval [CI] 2.10 to 140.66), as well as the presence of coronary artery disease (OR 6.86, 95 CI% 1.18 to 40.05), were independently associated with postoperative cerebrovascular accident development. Overall hospital mortality was 9.2%, with no significant difference for patients hit by cerebrovascular accidents (25.0% vs 7.3%, p = 0.102). Preexisting coronary artery disease, reflecting a severe diseased aorta and anomalies of Willis circle are independent cerebrovascular accident predictors after thoracic endovascular aortic repair procedures. A careful evaluation of the arch vessels and cerebral vascularization should be mandatory for patients suitable for thoracic endovascular aortic repair.

  12. Stent fractures in the Hemobahn/Viabahn stent graft after endovascular popliteal aneurysm repair

    NARCIS (Netherlands)

    Tielliu, Ignace F. J.; Zeebregts, Clark J.; Vourliotakis, George; Bekkema, Foppe; van den Dungen, Jan J. A. M.; Prins, Ted R.; Verhoeven, Eric L. G.

    Objective: During the last decade, endovascular repair of popliteal artery aneurysms (PAAs) has become a valid alternative to open repair. This study analyzes the incidence and origin of stein graft fractures after endovascular repair, its impact on patency, and strategies to prevent fractures.

  13. The impact of endovascular repair on specialties performing abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    Ultee, Klaas H J; Hurks, Rob; Buck, Dominique B.; Dasilva, George S.; Soden, Peter A.; Van Herwaarden, Joost A.; Verhagen, Hence J M; Schermerhorn, Marc L.

    2015-01-01

    Background Abdominal aortic aneurysm (AAA) repair has been performed by various surgical specialties for many years. Endovascular aneurysm repair (EVAR) may be a disruptive technology, having an impact on which specialties care for patients with AAA. Therefore, we examined the proportion of AAA

  14. The impact of endovascular repair on specialties performing abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    K.H.J. Ultee (Klaas); R. Hurks (Rob); D.B. Buck (Dominique B.); G.S. Dasilva (George S.); P.A. Soden (Peter A.); J.A. van Herwaarden (Joost); H.J.M. Verhagen (Hence); M.L. Schermerhorn (Marc)

    2015-01-01

    textabstractBackground Abdominal aortic aneurysm (AAA) repair has been performed by various surgical specialties for many years. Endovascular aneurysm repair (EVAR) may be a disruptive technology, having an impact on which specialties care for patients with AAA. Therefore, we examined the proportion

  15. Endovascular Aneurysm Repair and Sealing (EVARS): A Useful Adjunct in Treating Challenging Morphology

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Gareth J., E-mail: garethjamesharrison@yahoo.co.uk; Antoniou, George A., E-mail: antoniou.ga@hotmail.com; Torella, Francesco, E-mail: francesco.torella@rlbuht.nhs.uk; McWilliams, Richard G., E-mail: richard.mcwilliams@rlbuht.nhs.uk; Fisher, Robert K., E-mail: robert.fisher@rlbuht.nhs.uk [Royal Liverpool University Hospital, Liverpool Vascular and Endovascular Service (United Kingdom)

    2016-04-15

    An 81-year-old male with previous open abdominal aortic aneurysm repair presented with asymptomatic large pseudoaneurysms at both ends of an open surgical tube graft. Endovascular aneurysm sealing (EVAS) in combination with the iliac limbs of a standard endovascular aneurysm repair (EVAR) successfully excluded both pseudoaneurysms from circulation. We describe the combination of elements of EVAS and EVAR and have termed this endovascular aneurysm repair and sealing (EVARS). EVARS has the advantage of harnessing the benefits of endobag sealing in aortic necks unsuitable for standard EVAR whilst providing the security of accurate stent placement within short common iliac arteries. In conclusion, EVAS may be combined with standard endovascular iliac limbs and is a possible treatment option for pseudoaneurysm following open aneurysm repair.

  16. Predictors of Reintervention After Endovascular Repair of Isolated Iliac Artery Aneurysm

    International Nuclear Information System (INIS)

    Zayed, Hany A.; Attia, Rizwan; Modarai, Bijan; Clough, Rachel E.; Bell, Rachel E.; Carrell, Tom; Sabharwal, Tarun; Reidy, John; Taylor, Peter R.

    2011-01-01

    The objective of this study was to identify factors predicting the need for reintervention after endovascular repair of isolated iliac artery aneurysm (IIAA). We reviewed prospectively collected database records of all patients who underwent endovascular repair of IIAA between 1999 and 2008. Detailed assessment of the aneurysms was performed using computed tomography angiography (CTA). Follow-up protocol included CTA at 3 months. If this showed no complication, then annual duplex scan was arranged. Multivariate analysis and analysis of patient survival and freedom from reintervention were performed using Kaplan–Meier life tables. Forty IIAAs (median diameter 44 mm) in 38 patients were treated (all men; median age 75 years), and median follow-up was 27 months. Endovascular repair of IIAA was required in 14 of 40 aneurysms (35%). The rate of type I endoleak was significantly higher with proximal landing zone (PLZ) diameter >30 mm in the aorta or >24 mm in the common iliac artery or distal landing zone (DLZ) diameter >24 mm (P = 0.03, 0.03, and 0.0014, respectively). Reintervention rate (RR) increased significantly with increased diameter or decreased length of PLZ; increased DLZ diameter; and endovascular IIAA repair (P = 0.005, 0.005, 0.02, and 0.02 respectively); however, RR was not significantly affected by length of PLZ or DLZ. Freedom-from-reintervention was 97, 93, and 86% at 12, 24, and 108 months. There was no in-hospital or aneurysm-related mortality. Endovascular IIAA repair is a safe treatment option. Proper patient selection is essential to decrease the RR.

  17. Surgeon leadership in the coding, billing, and contractual negotiations for fenestrated endovascular aortic aneurysm repair increases medical center contribution margin and physician reimbursement.

    Science.gov (United States)

    Aiello, Francesco; Durgin, Jonathan; Daniel, Vijaya; Messina, Louis; Doucet, Danielle; Simons, Jessica; Jenkins, James; Schanzer, Andres

    2017-10-01

    Fenestrated endovascular aneurysm repair (FEVAR) allows endovascular treatment of thoracoabdominal and juxtarenal aneurysms previously outside the indications of use for standard devices. However, because of considerable device costs and increased procedure time, FEVAR is thought to result in financial losses for medical centers and physicians. We hypothesized that surgeon leadership in the coding, billing, and contractual negotiations for FEVAR procedures will increase medical center contribution margin (CM) and physician reimbursement. At the UMass Memorial Center for Complex Aortic Disease, a vascular surgeon with experience in medical finances is supported to manage the billing and coding of FEVAR procedures for medical center and physician reimbursement. A comprehensive financial analysis was performed for all FEVAR procedures (2011-2015), independent of insurance status, patient presentation, or type of device used. Medical center CM (actual reimbursement minus direct costs) was determined for each index FEVAR procedure and for all related subsequent procedures, inpatient or outpatient, 3 months before and 1 year subsequent to the index FEVAR procedure. Medical center CM for outpatient clinic visits, radiology examinations, vascular laboratory studies, and cardiology and pulmonary evaluations related to FEVAR were also determined. Surgeon reimbursement for index FEVAR procedure, related adjunct procedures, and assistant surgeon reimbursement were also calculated. All financial analyses were performed and adjudicated by the UMass Department of Finance. The index hospitalization for 63 FEVAR procedures incurred $2,776,726 of direct costs and generated $3,027,887 in reimbursement, resulting in a positive CM of $251,160. Subsequent related hospital procedures (n = 26) generated a CM of $144,473. Outpatient clinic visits, radiologic examinations, and vascular laboratory studies generated an additional CM of $96,888. Direct cost analysis revealed that grafts

  18. Development of stroke-induced quadriplegia after endovascular repair of blunt aortic injury pseudoaneurysm.

    Science.gov (United States)

    Amoudi, Abdullah S; Merdad, Anas A; Makhdoom, Ahmed Q; Jamjoom, Reda A

    2015-01-01

    Endovascular repair of blunt aortic injury is now a first-line approach in management. This can warrant coverage of the left subclavian artery (LSA), which could lead to posterior strokes. In this case report, we present a severe complication of endovascular repair of a traumatic aortic aneurysm. A 53-year-old man presented with blunt aortic injury, endovascular repair was carried out where the left subclavian artery was covered. The intervention had a 100% technical success. Twelve hours later, he was discovered to have quadriplegia, a CT scan showed a large left cerebellar infarction extending to the medulla oblongata and proximal spinal cord. Strokes complicate 3% of thoracic endovascular aortic repairs, 80% of those strokes occur in patients who had their LSA`s covered. Most patients however, tolerate the coverage. Although our patient had a dominant right vertebral artery, and lacked risks for these strokes, he developed an extensive stroke that left him quadriplegic.

  19. Cost-effectiveness of endovascular repair, open repair, and conservative management of splenic artery aneurysms

    NARCIS (Netherlands)

    Hogendoorn, Wouter; Lavida, Anthi; Hunink, M. G Myriam; Moll, Frans L.; Geroulakos, George; Muhs, Bart E.; Sumpio, Bauer E.

    2015-01-01

    Objective Open repair (OPEN) and conservative management (CONS) have been the treatments of choice for splenic artery aneurysms (SAAs) for many years. Endovascular repair (EV) has been increasingly used with good short-term results. In this study, we evaluated the cost-effectiveness of OPEN, EV, and

  20. Flow and wall shear stress characterization following endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model

    NARCIS (Netherlands)

    Boersen, Johannes T.; Groot Jebbink, Erik; Versluis, Michel; Slump, Cornelis H.; Ku, David N.; de Vries, Jean-Paul P.M.; Reijnen, Michel M.P.J.

    2017-01-01

    Background Endovascular aneurysm repair (EVAR) with a modular endograft has become the preferred treatment for abdominal aortic aneurysms. A novel concept is endovascular aneurysm sealing (EVAS), consisting of dual endoframes surrounded by polymer-filled endobags. This dual-lumen configuration is

  1. A case of acute ischemic colitis after endovascular abdominal aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Grigorios Voulalas

    2016-01-01

    Full Text Available Colonic ischemia is a recognized complication of either open or endovascular abdominal aortic aneurysm repair. The clinical difficulty in establishing the diagnosis, the severity of this complication and the patient's poor physiological status may lead to a fatal outcome. We presented a case of ischemic colitis in a patient with patent hypogastric arteries that occurred after an endovascular abdominal aortic aneurysm repair as well as a review of the available literature. The patient's preoperative, intraoperative and postoperative data were recorded. A thorough search through the Google data and Medline to review similar cases or any analyses that referred to ischemic colitis after endovascular abdominal aneurysm repair was conducted. A 76-year-old male was admitted to our department for an elective endovascular repair of an 8 cm in diameter abdominal aortic aneurysm. A Zenith bifurcation graft was implanted. The whole procedure was uneventful and the final angiogram showed an accurate deployment of the endograft without endoleaks and patency of both hypogastric arteries. During the 1st postoperative day, the patient developed symptoms of acute abdomen in combination with metabolic acidosis and oliguria. He underwent an exploratory laparotomy, which revealed necrosis of the sigmoid. A Hartmann's procedure was performed; the patient was transferred to the intensive care unit where he deceased after 24 h. Postoperative ischemic colitis has been described after open abdominal aneurysm repair. The description of this complication has been reported since the early phase of endovascular abdominal aneurysm repair development with a current incidence of 1.5%–3.0%. Possible mechanisms that may contribute to ischemic colitis in spite of the presence of patent hypogastric arteries include atheroembolization, shock, vasopressive drugs and inferior mesenteric artery occlusion.

  2. Aneurysm growth after late conversion of thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Hirofumi Kasahara

    2015-01-01

    Full Text Available A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four sequential computed tomography scans demonstrated that the aneurysm was additionally increasing in size probably due to continuous hematoma production, suggesting a possibility of endoleaks. This case demonstrates the importance of careful radiologic surveillance after endovascular repair, and also after partial open conversion.

  3. Endovascular repair of aortic disease: a venture capital perspective.

    Science.gov (United States)

    Buchanan, Lucas W; Stavropoulos, S William; Resnick, Joshua B; Solomon, Jeffrey

    2009-03-01

    Endovascular devices for the treatment of abdominal and thoracic aortic disease are poised to become the next $1 billion medical device market. A shift from open repair to endovascular repair, advances in technology, screening initiatives, and new indications are driving this growth. Although billion-dollar medical device markets are rare, this field is fraught with risk and uncertainty for startups and their venture capital investors. Technological hurdles, daunting clinical and regulatory timelines, market adoption issues, and entrenched competitors pose significant barriers to successful new venture creation. In fact, the number of aortic endografts that have failed to reach commercialization or have been pulled from the market exceeds the number of Food and Drug Administration-approved endografts in the United States. This article will shed some light on the venture capital mind-set and decision-making paradigm in the context of aortic disease.

  4. Aorto-enteric Fistula 15 Years After Uncomplicated Endovascular Aortic Repair with Unforeseen Onset of Endocarditis

    DEFF Research Database (Denmark)

    Kadhim, M M K; Rasmussen, J B G; Eiberg, J P

    2016-01-01

    Introduction Aorto-enteric fistula after endovascular aortic repair is an exceedingly rare but serious condition. Report A rare case of a fistula between the excluded aortic sac and the transverse colon 15 years after endovascular aortic repair is described. Onset was endocarditis without...... such as endocarditis, which in this case probably occurred as metastatic sepsis from endograft infection....

  5. Suprarenal fixation barbs can induce renal artery occlusion in endovascular aortic aneurysm repair.

    Science.gov (United States)

    Subedi, Shree K; Lee, Andy M; Landis, Gregg S

    2010-01-01

    Renal artery occlusion following endovascular abdominal aortic aneurysm repair with suprarenal fixation is uncommon. We report one patient who was found to develop renal artery occlusion and parenchymal infarction 6 months after repair using an endovascular graft with suprarenal fixation. Our patient underwent emergent endovascular repair of a symptomatic 6 cm abdominal aortic aneurysm. The covered portion of the endograft was inadvertently deployed well below the renal artery orifices. At the completion of the procedure both renal arteries were confirmed to be patent. One month postoperatively, a computed tomographic (CT) scan showed exclusion of the aortic sac and normal enhancement of both kidneys. At 6 months, the patient was found to have elevated serum creatinine levels despite having no clinical symptoms. CT scanning revealed a nonenhancing left kidney, and angiography demonstrated an occlusion of the left renal artery. A barb welded to the bare metal stent appeared to be impinging on the renal artery. We believe that renal artery occlusion after endovascular repair can occur due to repetitive injury to the renal artery orifice from barbs welded to the bare metal stent. To our knowledge, this is the first reported case of renal artery occlusion caused by repetitive injury from transrenal fixation systems. Copyright 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  6. Contemporary economic and clinical evaluations of endovascular repair for intact descending thoracic aortic aneurysms.

    Science.gov (United States)

    Silingardi, Roberto; Gennai, Stefano; Coppi, Giovanni; Chester, Johanna; Marcheselli, Luigi; Brunetti, Massimo

    2017-12-01

    The aim of this study was to assess clinical and contemporary costs associated with elective endovascular repair of intact descending thoracic aortic aneurysms (DTAA) into the mid-term follow-up. A retrospective review of a prospectively maintained clinical database including 29 consecutive patients from July 2005 to December 2009 treated with elective endovascular repair (TEVAR) or TEVAR and surgical infrarenal repair (hybrid) of intact DTAA was performed. Mean age was 74.5 years old (±7.1). Primary clinical endpoints include mortality and major morbidity. Additionally a comprehensive economic appraisal of individual in-hospital and follow-up costs was executed. Economic endpoints include in-hospital and follow-up costs and patient discharge status. Elective endovascular and open repairs' clinical and economical outcomes in contemporary literature were assessed for comparison according to PRISMA standards. Immediate mortality was 6.9% (1/24 TEVAR and 1/5 hybrid). Three respiratory complications were recorded (11%; 2 TEVAR, 1 hybrid). Renal and cardiac complication rates were 7.4% (1 TEVAR, 1 hybrid) and 3.7% (1 TEVAR) respectively. Routine discharge home was achieved for 85% of patients (95.7% TEVAR, 25% hybrid). Three endoleaks were treated throughout the follow-up (2 TEVAR, 1 hybrid; mean 30.4 mo, ±19.9) rendering an 11% (3/27) reintervention rate. Average immediate cost was €21,976.87 for elective endovascular repair and €33,783.21 for elective endovascular hybrid repair. Additional reintervention and routine follow-up costs augmented immediate costs by 12.4%. This study supports satisfying immediate clinical outcomes for TEVAR and TEVAR+surgical infrarenal procedures. Although limited by a small population size and difficulties in economic comparisons, this study presents the real world social and economic cost scenario for both elective TEVAR and TEVAR hybrid treatment of DTAA of both the in-hospital and at mid term follow-up periods.

  7. Endovascular repair of early rupture of Dacron aortic graft--two case reports.

    LENUS (Irish Health Repository)

    Sultan, Sherif

    2005-01-01

    Complications after open aortic surgery pose a challenge both to the vascular surgeon and the patient because of aging population, widespread use of cardiac revascularization, and improved survival after aortic surgery. The perioperative mortality rate for redo elective aortic surgery ranges from 5% to 29% and increases to 70-100% in emergency situation. Endovascular treatment of the postaortic open surgery (PAOS) patient has fewer complications and a lower mortality rate in comparison with redo open surgical repair. Two cases of ruptured abdominal aortic aneurysm (AAA) were managed with the conventional open surgical repair. Subsequently, spiral contrast computer tomography scans showed reperfusion of the AAA sac remnant mimicking a type III endoleak. These graft-related complications presented as vascular emergencies, and in both cases endovascular aneurysm repair (EVAR) procedure was performed successfully by aortouniiliac (AUI) stent graft and femorofemoral crossover bypass. These 2 patients add further merit to the cases reported in the English literature. This highlights the crucial importance of endovascular grafts in the management of such complex vascular problems.

  8. A multidetector tomography protocol for follow-up of endovascular aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Roberto Moraes Bastos

    2011-01-01

    Full Text Available OBJECTIVE: The purpose of this study was to improve the use of 64-channel multidetector computed tomography using lower doses of ionizing radiation during follow-up procedures in a series of patients with endovascular aortic aneurysm repair. METHODS: Thirty patients receiving 5 to 29 months of follow-up after endovascular aortic aneurysm repair were analyzed using a 64-channel multidetector computed tomography device by an exam that included pre-and postcontrast with both arterial and venous phases. Leak presence and type were classified based on the exam phase. RESULTS: Endoleaks were identified in 8/30 of cases; the endoleaks in 3/8 of these cases were not visible in the arterial phases of the exams. CONCLUSION: The authors conclude that multidetector computed tomography with pre-contrast and venous phases should be a part of the ongoing follow-up of patients undergoing endovascular aortic aneurysm repair. The arterial phase can be excluded when the aneurism is stable or regresses. These findings permit a lower radiation dose without jeopardizing the correct diagnosis of an endoleak.

  9. Salvage of bilateral renal artery occlusion after endovascular aneurysm repair with open splenorenal bypass

    Directory of Open Access Journals (Sweden)

    Samuel Jessula, MDCM

    2017-09-01

    Full Text Available We report renal salvage maneuvers after accidental bilateral renal artery coverage during endovascular aneurysm repair of an infrarenal abdominal aortic aneurysm. A 79-year-old man with an infrarenal abdominal aortic aneurysm was treated with endovascular aneurysm repair. Completion angiography demonstrated coverage of the renal arteries. Several revascularization techniques were attempted, including endograft repositioning and endovascular stenting through the femoral and brachial approach. The patient eventually underwent open splenorenal bypass with a Y Gore-Tex graft (W. L. Gore & Associates, Flagstaff, Ariz. After 3 months, computed tomography showed no evidence of endoleak and patent renal arteries. Renal function was well maintained, and the patient did not require dialysis.

  10. Radiation Exposure in Endovascular Infra-Renal Aortic Aneurysm Repair and Factors that Influence It

    Directory of Open Access Journals (Sweden)

    Rui Machado

    Full Text Available Abstract Objective: The endovascular repair of aortic abdominal aneurysms exposes the patients and surgical team to ionizing radiation with risk of direct tissue damage and induction of gene mutation. This study aims to describe our standard of radiation exposure in endovascular aortic aneurysm repair and the factors that influence it. Methods: Retrospective analysis of a prospective database of patients with abdominal infra-renal aortic aneurysms submitted to endovascular repair. This study evaluated the radiation doses (dose area product (DAP, fluoroscopy durations and their relationships to the patients, aneurysms, and stent-graft characteristics. Results: This study included 127 patients with a mean age of 73 years. The mean DAP was 4.8 mGy.m2, and the fluoroscopy time was 21.8 minutes. Aortic bilateral iliac aneurysms, higher body mass index, aneurysms with diameters larger than 60 mm, necks with diameters larger than 28 mm, common iliac arteries with diameters larger than 20 mm, and neck angulations superior to 50 degrees were associated with an increased radiation dose. The number of anatomic risk factors present was associated with increased radiation exposure and fluoroscopy time, regardless of the anatomical risk factors. Conclusion: The radiation exposure during endovascular aortic aneurysm repair is significant (mean DAP 4.8 mGy.m2 with potential hazards to the surgical team and the patients. The anatomical characteristics of the aneurysm, patient characteristics, and the procedure's technical difficulty were all related to increased radiation exposure during endovascular aortic aneurysm repair procedures. Approximately 40% of radiation exposure can be explained by body mass index, neck angulation, aneurysm diameter, neck diameter, and aneurysm type.

  11. Endovascular strategy or open repair for ruptured abdominal aortic aneurysm: one-year outcomes from the IMPROVE randomized trial

    Science.gov (United States)

    Braithwaite, Bruce; Cheshire, Nicholas J.; Greenhalgh, Roger M.; Grieve, Richard; Hassan, Tajek B.; Hinchliffe, Robert; Howell, Simon; Moore, Fionna; Nicholson, Anthony A.; Soong, Chee V.; Thompson, Matt M.; Thompson, Simon G.; Ulug, Pinar; Heatley, Francine; Anjum, Aisha; Kalinowska, Gosia; Sweeting, Michael J.; Thompson, Simon G.; Gomes, Manuel; Grieve, Richard; Powell, Janet T.; Ashleigh, Ray; Gomes, Manuel; Greenhalgh, Roger M.; Grieve, Richard; Hinchliffe, Robert; Sweeting, Michael; Thompson, Matt M.; Thompson, Simon G.; Ulug, Pinar; Roberts, Ian; Bell, Peter R. F.; Cheetham, Anne; Stephany, Jenny; Warlow, Charles; Lamont, Peter; Moss, Jonathan; Tijssen, Jan; Braithwaite, Bruce; Nicholson, Anthony A.; Thompson, Matthew; Ashleigh, Ray; Thompson, Luke; Cheshire, Nicholas J.; Boyle, Jonathan R.; Serracino-Inglott, Ferdinand; Thompson, Matt M.; Hinchliffe, Robert J.; Bell, Rachel; Wilson, Noel; Bown, Matt; Dennis, Martin; Davis, Meryl; Ashleigh, Ray; Howell, Simon; Wyatt, Michael G.; Valenti, Domenico; Bachoo, Paul; Walker, Paul; MacSweeney, Shane; Davies, Jonathan N.; Rittoo, Dynesh; Parvin, Simon D.; Yusuf, Waquar; Nice, Colin; Chetter, Ian; Howard, Adam; Chong, Patrick; Bhat, Raj; McLain, David; Gordon, Andrew; Lane, Ian; Hobbs, Simon; Pillay, Woolagasen; Rowlands, Timothy; El-Tahir, Amin; Asquith, John; Cavanagh, Steve; Dubois, Luc; Forbes, Thomas L.; Ashworth, Emily; Baker, Sara; Barakat, Hashem; Brady, Claire; Brown, Joanne; Bufton, Christine; Chance, Tina; Chrisopoulou, Angela; Cockell, Marie; Croucher, Andrea; Dabee, Leela; Dewhirst, Nikki; Evans, Jo; Gibson, Andy; Gorst, Siobhan; Gough, Moira; Graves, Lynne; Griffin, Michelle; Hatfield, Josie; Hogg, Florence; Howard, Susannah; Hughes, Cían; Metcalfe, David; Lapworth, Michelle; Massey, Ian; Novick, Teresa; Owen, Gareth; Parr, Noala; Pintar, David; Spencer, Sarah; Thomson, Claire; Thunder, Orla; Wallace, Tom; Ward, Sue; Wealleans, Vera; Wilson, Lesley; Woods, Janet; Zheng, Ting

    2015-01-01

    Aims To report the longer term outcomes following either a strategy of endovascular repair first or open repair of ruptured abdominal aortic aneurysm, which are necessary for both patient and clinical decision-making. Methods and results This pragmatic multicentre (29 UK and 1 Canada) trial randomized 613 patients with a clinical diagnosis of ruptured aneurysm; 316 to an endovascular first strategy (if aortic morphology is suitable, open repair if not) and 297 to open repair. The principal 1-year outcome was mortality; secondary outcomes were re-interventions, hospital discharge, health-related quality-of-life (QoL) (EQ-5D), costs, Quality-Adjusted-Life-Years (QALYs), and cost-effectiveness [incremental net benefit (INB)]. At 1 year, all-cause mortality was 41.1% for the endovascular strategy group and 45.1% for the open repair group, odds ratio 0.85 [95% confidence interval (CI) 0.62, 1.17], P = 0.325, with similar re-intervention rates in each group. The endovascular strategy group and open repair groups had average total hospital stays of 17 and 26 days, respectively, P < 0.001. Patients surviving rupture had higher average EQ-5D utility scores in the endovascular strategy vs. open repair groups, mean differences 0.087 (95% CI 0.017, 0.158), 0.068 (95% CI −0.004, 0.140) at 3 and 12 months, respectively. There were indications that QALYs were higher and costs lower for the endovascular first strategy, combining to give an INB of £3877 (95% CI £253, £7408) or €4356 (95% CI €284, €8323). Conclusion An endovascular first strategy for management of ruptured aneurysms does not offer a survival benefit over 1 year but offers patients faster discharge with better QoL and is cost-effective. Clinical trial registration ISRCTN 48334791. PMID:25855369

  12. Open Versus Endovascular Stent Graft Repair of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Firwana, Belal; Ferwana, Mazen; Hasan, Rim

    2014-01-01

    We performed an analysis to assess the need for conducting additional randomized controlled trials (RCTs) comparing open and endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA). Trial sequential analysis (TSA) is a statistical methodology that can calculate the required inform...

  13. Outcome after endovascular abdominal aortic aneurysm repair: a meta-analysis.

    NARCIS (Netherlands)

    Walschot, L.H.B.; Laheij, R.J.F.; Verbeek, A.L.M.

    2002-01-01

    PURPOSE: To determine the frequencies of complications and risk factors for complications following endovascular abdominal aortic aneurysm (AAA) repair (EVAR). METHODS: Thirty-nine articles published between October 1995 and October 1999 in English, German, French, or Dutch were identified in

  14. Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

    Science.gov (United States)

    Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A; Krajcer, Zvonimir

    2015-02-01

    After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta.

  15. Intensive Care Management of Thoracic Aortic Surgical Patients, Including Thoracic and Infradiaphragmatic Endovascular Repair (EVAR/TEVAR).

    Science.gov (United States)

    Cole, Sheela Pai

    2015-12-01

    The patient with thoracic aortic disease can present for open or endovascular repair. Thoracic endovascular aortic repair (TEVAR) has emerged as a minimally invasive option for a multitude of aortic pathology, including dissections, aneurysms, traumatic injuries, and ulcers. Postoperative management of these patients depends on the extent of procedure, whether it was open or endovascular, and, finally, on the preoperative comorbidities present. While procedural success has catapulted TEVAR to popularity, midterm results have been mixed. Additionally, periprocedural complications such as paraplegia and renal failure remain a significant morbidity in these patients. © The Author(s) 2015.

  16. Strategy of endovascular versus open repair for patients with clinical diagnosis of ruptured abdominal aortic aneurysm: the IMPROVE RCT.

    Science.gov (United States)

    Ulug, Pinar; Hinchliffe, Robert J; Sweeting, Michael J; Gomes, Manuel; Thompson, Matthew T; Thompson, Simon G; Grieve, Richard J; Ashleigh, Raymond; Greenhalgh, Roger M; Powell, Janet T

    2018-05-01

    Ruptured abdominal aortic aneurysm (AAA) is a common vascular emergency. The mortality from emergency endovascular repair may be much lower than the 40-50% reported for open surgery. To assess whether or not a strategy of endovascular repair compared with open repair reduces 30-day and mid-term mortality (including costs and cost-effectiveness) among patients with a suspected ruptured AAA. Randomised controlled trial, with computer-generated telephone randomisation of participants in a 1 : 1 ratio, using variable block size, stratified by centre and without blinding. Vascular centres in the UK ( n  = 29) and Canada ( n  = 1) between 2009 and 2013. A total of 613 eligible participants (480 men) with a ruptured aneurysm, clinically diagnosed at the trial centre. A total of 316 participants were randomised to the endovascular strategy group (immediate computerised tomography followed by endovascular repair if anatomically suitable or, if not suitable, open repair) and 297 were randomised to the open repair group (computerised tomography optional). The primary outcome measure was 30-day mortality, with 30-day reinterventions, costs and disposal as early secondary outcome measures. Later outcome measures included 1- and 3-year mortality, reinterventions, quality of life (QoL) and cost-effectiveness. The 30-day mortality was 35.4% in the endovascular strategy group and 37.4% in the open repair group [odds ratio (OR) 0.92, 95% confidence interval (CI) 0.66 to 1.28; p  = 0.62, and, after adjustment for age, sex and Hardman index, OR 0.94, 95% CI 0.67 to 1.33]. The endovascular strategy appeared to be more effective in women than in men (interaction test p  = 0.02). More discharges in the endovascular strategy group (94%) than in the open repair group (77%) were directly to home ( p  open repair group, respectively (OR 0.73, 95% CI 0.53 to 1.00; p  = 0.053), with a stronger benefit for the endovascular strategy in the subgroup of 502 participants

  17. Dynamic CE-MRA for endoleak classification after endovascular aneurysm repair.

    NARCIS (Netherlands)

    Laan, M.J. van der; Bakker, C.J.; Blankensteijn, J.D.; Bartels, L.W.

    2006-01-01

    AIM: To evaluate the value of dynamic contrast enhanced magnetic resonance angiography (CE-MRA) for classification of endoleaks after endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: Twenty-eight patients, between 2 days and 54 months after EVAR, were evaluated with CTA, MRI and dynamic

  18. Dynamic CE=MRA for endoleak classification after endovascular aneurysm repair

    NARCIS (Netherlands)

    van der Laan, MJ; Bakker, CJG; Blankensteijn, JD; Bartels, LW

    Aim. To evaluate the value of dynamic contrast enhanced magnetic resonance angiography (CE-MRA)for classification of endoleaks after endovascular aneurysm repair (EVAR). Materials and methods. Twenty-eight patients, between 2 days and 54 months after EVAR, were evaluated with CTA, MRI and dynamic

  19. Endovascular Repair of Aortic Dissection in Marfan Syndrome: Current Status and Future Perspectives

    Directory of Open Access Journals (Sweden)

    Rosario Parisi

    2015-07-01

    Full Text Available Over the last decades, improvement of medical and surgical therapy has increased life expectancy in Marfan patients. Consequently, the number of such patients requiring secondary interventions on the descending thoracic aorta due to new or residual dissections, and distal aneurysm formation has substantially enlarged. Surgical and endovascular procedures represent two valuable options of treatment, both associated with advantages and drawbacks. The aim of the present manuscript was to review endovascular outcomes in Marfan syndrome and to assess the potential role of Thoracic Endovascular Aortic Repair (TEVAR in this subset of patients.

  20. Nursing cooperation in endovascular aneurysm repair treatment for aortic dissection

    International Nuclear Information System (INIS)

    Xing Li; Yuan Chanjuan; Chen Rumei; Xiao Zhanqiang; Qi Youfei

    2014-01-01

    Objective: To summarize the main points of nursing cooperation in endovascular aneurysm repair treatment for aortic dissection. Methods: Preoperative psychological care and the other preparations were carefully conducted. During the operation, the patient's body was correctly placed. Active cooperation with the performance of angiography and close observation during heparinization were carried out. The proper delivery of catheter and stent to the operator was carefully done. Close observation for the patient's vital signs, the renal function and the changes of limb blood supply were made. Results: Under close cooperation of' the operators, nurses, anesthesiologists and technicians, the surgery was successfully accomplished in 35 patients. The monitoring of vital signs during the entire performance of operation was well executed. No surgical instruments delivery error's or surgery failure due to unsuitable cooperation occurred. Conclusion: Perfect preoperative preparation, strict nursing cooperation and team cooperation are the key points to ensure a successful endovascular aneurysm repair for aortic dissection. (authors)

  1. ChEVAS: Combining Suprarenal EVAS with Chimney Technique

    Energy Technology Data Exchange (ETDEWEB)

    Torella, Francesco, E-mail: f.torella@liverpool.ac.uk [Royal Liverpool University Hospital, Liverpool Vascular & Endovascular Service (United Kingdom); Chan, Tze Y., E-mail: tze.chan@rlbuht.nhs.uk; Shaikh, Usman, E-mail: usman.shaikh@rlbuht.nhs.uk [Royal Liverpool University Hospital, Department of Radiology (United Kingdom); England, Andrew, E-mail: a.england@salford.ac.uk [University of Salford, Department of Radiography (United Kingdom); Fisher, Robert K., E-mail: robert.fisher@rlbuht.nhs.uk [Royal Liverpool University Hospital, Liverpool Vascular & Endovascular Service (United Kingdom); McWilliams, Richard G., E-mail: richard.mcwilliams@rlbuht.nhs.uk [Royal Liverpool University Hospital, Department of Radiology (United Kingdom)

    2015-10-15

    Endovascular sealing with the Nellix{sup ®} endoprosthesis (EVAS) is a new technique to treat infrarenal abdominal aortic aneurysms. We describe the use of endovascular sealing in conjunction with chimney stents for the renal arteries (chEVAS) in two patients, one with a refractory type Ia endoleak and an expanding aneurysm, and one with a large juxtarenal aneurysm unsuitable for fenestrated endovascular repair (EVAR). Both aneurysms were successfully excluded. Our report confirms the utility of chEVAS in challenging cases, where suprarenal seal is necessary. We suggest that, due to lack of knowledge on its durability, chEVAS should only been considered when more conventional treatment modalities (open repair and fenestrated EVAR) are deemed difficult or unfeasible.

  2. Outcomes of endovascular aortic repair in the modern era

    DEFF Research Database (Denmark)

    Budtz-Lilly, Jacob; Wanhainen, Anders; Mani, Kevin

    2018-01-01

    Monitoring outcomes following endovascular aortic repair (EVAR) is critical. Although evidence from randomized controlled trials has solidified the role of EVAR, the analysis of outcomes and "real-world" data has uncovered limitations, improved the selection of appropriate patients, and underscored...... the importance of instructions for use. Subsequent studies demonstrated the learning curve of EVAR and gradual improvement of outcomes over time. Outcomes analyses will continue to play an important role, particularly as technological growth of endovascular therapy has enabled treatment of more complex aneurysm...... pathologies and patients. The important analyses are herein reviewed, following the development of EVAR in the treatment of intact abdominal aortic aneurysms (AAA) to ruptured AAAs, and finally to complex aneurysms, including thoracoabdominal aortic aneurysms and mycotic aneurysms. This includes an overview...

  3. Open fenestration of the distal landing zone via a subxyphoid incision for subsequent endovascular repair of a dissecting thoracic aneurysm.

    Science.gov (United States)

    Konings, Renske; de Bruin, Jorg L; Wisselink, Willem

    2013-02-01

    To describe a novel hybrid technique to address two challenges in endovascular repair of chronic dissecting thoracic aortic aneurysm (dTAA): obtaining an adequate seal of the stent-graft in a half-moon-shaped fibrotic aortic lumen and preserving flow into the distal true and false lumens. The technique is demonstrated in a 52-year-old man who presented with progressive asymptomatic dilatation of the thoracic aorta 9 years after undergoing a Bentall procedure for a Stanford type A dissection followed by arch replacement and elephant trunk construction. Imaging at this admission showed a 6.8-cm dissecting aneurysm extending distally to ∼4 cm above the celiac trunk; the dissection included both common iliac arteries. The patient refused a thoracotomy, so a hybrid procedure was devised to resect the intimal flap via a median subxyphoid incision and transperitoneal approach through the lesser sac. Two overlapping Zenith TX-2 stent-grafts were deployed into the elephant trunk, terminating just above the surgically created "flow divider" at the level of the celiac trunk. Imaging showed adequate sealing at both ends of the stent-graft and a type II endoleak that persisted into follow-up, but the aneurysm diameter decreased to 6.4 cm, and there was unobstructed flow into the visceral, renal, and iliac arteries. In this case of chronic dTAA, open surgical removal of a segment of the dissection flap via a subxyphoid incision provided a distal landing zone for subsequent endoluminal repair, with exclusion of the aneurysm and preservation of antegrade flow in both true and false lumens.

  4. Sex differences in 30-day and 5-year outcomes after endovascular repair of abdominal aortic aneurysms in the EUROSTAR study

    DEFF Research Database (Denmark)

    Grootenboer, Nathalie; Hunink, M G Myriam; Hendriks, Johanna M

    2013-01-01

    The purpose of this study was to determine the effect of sex on 30-day and long-term outcomes after elective endovascular aneurysm repair.......The purpose of this study was to determine the effect of sex on 30-day and long-term outcomes after elective endovascular aneurysm repair....

  5. Covered stents for endovascular repair of iatrogenic injuries of iliac and femoral arteries

    Energy Technology Data Exchange (ETDEWEB)

    Kufner, Sebastian, E-mail: kufners@dhm.mhn.de [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Cassese, Salvatore; Groha, Philipp; Byrne, Robert A. [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Schunkert, Heribert; Kastrati, Adnan [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany); Ott, Ilka; Fusaro, Massimiliano [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany)

    2015-04-15

    Background: The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. A strategy of percutaneous transluminal angioplasty (PTA) with covered stent (CS) may represent a valuable alternative to open surgery. However, systematic evaluations of CS in this setting represent a scientific gap. In the present study, we investigate the procedural and clinical outcomes associated with PTA and CS implantation to repair iatrogenic injuries of peripheral arteries. Methods: All patients undergoing PTA with CS for endovascular repair of iatrogenic injuries of peripheral arteries between August 2010 and July 2013 at our Institution were retrospectively analyzed. The primary endpoint was the technical success. Secondary endpoints were in-hospital mortality and cumulative death, target lesion revascularization (TLR), amputation and major stroke at 12-month follow-up. Results: During the period of observation, a total of 30 patients underwent PTA with either self-expandable (43.3%) or balloon-expandable CS (56.7%) for iatrogenic injuries of peripheral arteries. Injuries consisted of perforation/rupture (76.7%), arteriovenous fistula (16.7%) and pseudoaneurysm (6.7%) of iliac–femoral arteries. Technical success was achieved in all cases. Median follow-up was 409 days [210–907]. The incidence of in-hospital mortality was 10.0%. At 12-month follow-up, the incidence of death, TLR, amputation and major stroke was 20.0%, 17.0%, 3.3% and 6.7%, respectively. Conclusion: The use of covered stents for endovascular repair of iatrogenic injuries of peripheral arteries shows a high technical success and may be alternative to surgery. Further studies with larger populations are needed to confirm these preliminary findings. - Highlights: • The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. • Percutaneous transluminal angioplasty with

  6. Comparison of hybrid endovascular and open surgical repair for proximal aortic arch diseases.

    Science.gov (United States)

    Kang, Woong Chol; Ko, Young-Guk; Shin, Eak Kyun; Park, Chul-Hyun; Choi, Donghoon; Youn, Young Nam; Lee, Do Yun

    2016-01-15

    To compare the outcomes of hybrid endovascular and open surgical repair for proximal aortic arch diseases. A total of 55 consecutive patients with aortic arch aneurysm or aortic dissection involving any of zone 0 to 1 (39 male, age 63.4 ± 14.3 years) underwent a hybrid endovascular repair (n=35) or open surgical repair (n=20) from 2006 to 2014 were analyzed retrospectively. Perioperative and late outcomes were compared. Baseline characteristics were similar between the two groups, except age and EuroSCORE II, which were higher in the hybrid group. Perioperative mortality or stroke was not significantly different between the two groups, however, tended to be lower in the hybrid repair group than in the open repair group (11.4% vs. 30.0%, p=0.144). Incidences of other morbidities did not differ. During follow-up, over-all survival was similar between the hybrid and the open repair was similar (87.3% vs. 79.7% at 1 year and 83.8% vs. 72.4% at 3 years; p=0.319). However, reintervention-free survival was significantly lower for hybrid repair compared with open repair (83.8% vs. 100% at 1 year and 65.7% vs. 100% at 3 years; p=0.022). Hybrid repair of proximal aortic disease showed comparable perioperative and late outcomes compared with open surgical repair despite a higher reintervention rate during follow-up. Therefore, hybrid repair may be considered as an acceptable treatment alternative to surgery especially in patients at high surgical risk. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Hybrid Endovascular Aortic Aneurysm Repair: Preservation of Pelvic Perfusion with External to Internal Iliac Artery Bypass.

    Science.gov (United States)

    Mansukhani, Neel A; Havelka, George E; Helenowski, Irene B; Rodriguez, Heron E; Hoel, Andrew W; Eskandari, Mark K

    2017-07-01

    Diminished pelvic arterial flow as a result of intentional coverage/embolization of internal iliac arteries (IIA) during isolated endovascular common iliac artery aneurysm (CIAA) repair or endovascular repair of abdominal aortic aneurysms (EVAR) may result in symptomatic pelvic ischemia. Although generally well tolerated, in severe cases, pelvic ischemia may manifest as recalcitrant buttock claudication, vasculogenic impotence, or perineal, vesicle, rectal, and/or spinal cord ischemia. Branched graft technology has recently become available; however, many patients are not candidates for endovascular repair with these devices. Therefore, techniques to preserve pelvic arterial flow are needed. We reviewed our outcomes of isolated endovascular CIAA repair or EVAR in conjunction with unilateral external-internal iliac artery bypass. Single-center, retrospective review of 10 consecutive patients who underwent hybrid endovascular abdominal aortic aneurysm (AAA) or CIAA repair with concomitant external-internal iliac artery bypass between 2006 and 2015. Demographics, index procedural details, postoperative symptoms, hospital length of stay (LOS), follow-up imaging, and bypass patency were recorded. The cohort of 10 patients was all men with a mean age of 71 years (range: 56-84). Hybrid repair consisted of contralateral IIA coil embolization followed by EVAR with external iliac artery-internal iliac artery (EIA-IIA) bypass. All EIA-IIA bypasses were performed via a standard lower quadrant retroperitoneal approach with a prosthetic bypass graft. Technical success was 100%, and there were no perioperative deaths. One patient developed transient paraplegia, 1 patient had buttock claudication on the side of his hypogastric embolization contralateral to his iliac bypass, and 1 developed postoperative impotence. 20% of patients sustained long-term complications (buttock claudication and postoperative impotence). Mean LOS was 2.8 days (range: 1-9 days). Postoperative imaging

  8. Progressive shortfall in open aneurysm experience for vascular surgery trainees with the impact of fenestrated and branched endovascular technology.

    Science.gov (United States)

    Dua, Anahita; Koprowski, Steven; Upchurch, Gilbert; Lee, Cheong J; Desai, Sapan S

    2017-01-01

    In 2014, we published a series of articles in the Journal of Vascular Surgery that detailed the decrease in volume of open aneurysm repair (OAR) completed for abdominal aortic aneurysm (AAA) by vascular surgery trainees. At that time, only data points from 2000 through 2011 were available, and reliable predictions could only be made through 2015. Lack of data on endovascular aneurysm repair (EVAR) using fenestrated (FEVAR) and branched (BrEVAR) endografts also affected our findings. Despite these limitations, our predictions for OAR completed by vascular trainees were accurate for 2012 to 2014. This report uses updated data points through 2014 in conjunction with data on FEVAR and BrEVAR obtained from industry to predict trends in OAR and how it will affect vascular surgery training through 2020. An S-curve modified logistic function was used to model the effect of introducing new technologies (EVAR, FEVAR, BrEVAR) on the standard management of AAA with OAR starting in the year 2000, similar to the technique that we have previously described. Weighted samples and data from the United States Census Bureau were used in conjunction with volume estimates derived from the National Inpatient Sample, State Inpatient Databases, and industry sources to determine trends in OAR and EVAR. The number of cases completed at teaching hospitals was calculated using the National Inpatient Sample, and Accreditation Council for Graduate Medical Education case logs were used to forecast the number of cases completed by vascular surgery trainees through 2020. Sensitivity analysis and trend analysis were completed. Approximately 45,000 AAA repairs are completed annually in the United States, but only 15% of these are now completed using OAR compared with >50% just a decade ago. Further, with the accelerating adoption of FEVAR and BrEVAR, and expanding indications for standard EVAR, our model predicts that model predicts that a vascular surgery trainee in a fellowship program will

  9. The Role of Transesophageal Echocardiography in Endovascular Repair of Traumatic Aortic Transection

    Directory of Open Access Journals (Sweden)

    Swathy B

    2014-09-01

    Full Text Available Traumatic rupture of the thoracic aorta is a leading cause of death, following major blunt trauma, and endovascular repair has evolved as a viable alternative to open repair. This report highlights the role of transesophageal echocardiography as a valuable imaging tool for locating the exact position of the lesion, guiding placement of the endograft, detecting leaks around it and supplementing information derived from angiography during endograft deployment.

  10. Late type III endoleak after thoracic endovascular aneurysm repair and previous infrarenal stent graft implantation - a case report and review of the literature.

    Science.gov (United States)

    Leszczyński, Jerzy; Macioch, Waldemar; Chudziński, Witold; Gałązka, Zbigniew

    2017-09-01

    Thoracic endovascular aortic repair (TEVAR) effectively improved the results of thoracic aortic aneurysm treatment. TEVAR is a less invasive procedure that can be performed under local anesthesia with shorter hospital stay. The perioperative morbidity and mortality rates are lower for endovascular than open repair, but the rate of secondary interventions is higher for TEVAR. We report a case of an elderly man with synchronous abdominal and thoracic aortic aneurysms. A type III dangerous endoleak was recognized 3 years after TEVAR. It was successfully repaired during an endovascular procedure. There were no new endoleaks after 12 months of follow-up. TEVAR may be the only option of treatment for risky and elderly patients. However, postoperative monitoring is necessary to exclude different types of endoleaks. Most of them undergo effective endovascular repair.

  11. Contemporary strategies for repair of complex thoracoabdominal aortic aneurysms: real-world experiences and multilayer stents as an alternative

    Directory of Open Access Journals (Sweden)

    Ralf Robert Kolvenbach

    Full Text Available Abstract Thoracoabdominal aortic aneurysms (TAAA present special challenges for repair due to their extent, their distinctive pathology, and the fact that they typically cross the ostia of one or more visceral branch vessels. Historically, the established treatment for TAAA was open surgical repair, with the first procedure reported in 1955. Endovascular repair of TAAA with fenestrated and/ or branched endografts, has been studied since the beginning of the current century as a means of mechanical aneurysm exclusion. More recently, flow modulator stents have been employed with the aim at reducing shear stress on aortic aneurysmal wall. In this review we present technical and main results of these techniques, based on literature review and personal experience.

  12. Embolization by micro navigation for treatment of persistent type 2 Endoleaks after endovascular abdominal aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Bruno Lorenção de Almeida

    2014-12-01

    Full Text Available Background:Endovascular repair has become established as a safe and effective method for treatment of abdominal aortic aneurysms. One major complication of this treatment is leakage, or endoleaks, of which type 2 leaks are the most common.Objective:To conduct a brief review of the literature and evaluate the safety and effectiveness of embolization by micronavigation for treatment of type 2 endoleaks.Method:A review of medical records from patients who underwent endovascular repair of abdominal aortic aneurysms identified 5 patients with persistent type 2 endoleaks. These patients were submitted to embolization by micronavigation.Results:In all cases, angiographic success was achieved and control CT scans showed absence of type 2 leaks and aneurysm sacs that had reduced in size after the procedure.Conclusion:Treatment of type 2 endoleaks using embolization by micronavigation is an effective and safe method and should be considered as a treatment option for this complication after endovascular repair of abdominal aortic aneurysms.

  13. The Role of Learning in Health Technology Assessments: An Empirical Assessment of Endovascular Aneurysm Repairs in German Hospitals.

    Science.gov (United States)

    Varabyova, Yauheniya; Blankart, Carl Rudolf; Schreyögg, Jonas

    2017-02-01

    Changes in performance due to learning may dynamically influence the results of a technology evaluation through the change in effectiveness and costs. In this study, we estimate the effect of learning using the example of two minimally invasive treatments of abdominal aortic aneurysms: endovascular aneurysm repair (EVAR) and fenestrated EVAR (fEVAR). The analysis is based on the administrative data of over 40,000 patients admitted with unruptured abdominal aortic aneurysm to more than 500 different hospitals over the years 2006 to 2013. We examine two patient outcomes, namely, in-hospital mortality and length of stay using hierarchical regression models with random effects at the hospital level. The estimated models control for patient and hospital characteristics and take learning interdependency between EVAR and fEVAR into account. In case of EVAR, we observe a significant decrease both in the in-hospital mortality and length of stay with experience accumulated at the hospital level; however, the learning curve for fEVAR in both outcomes is effectively flat. To foster the consideration of learning in health technology assessments of medical devices, a general framework for estimating learning effects is derived from the analysis. © 2017 The Authors. Health Economics published by John Wiley & Sons, Ltd. © 2017 The Authors. Health Economics published by John Wiley & Sons, Ltd.

  14. High risk endovascular aneurysm repair: a case report.

    Science.gov (United States)

    De Silva, Samanthi

    2017-10-01

    Mr AB is a 66-year old gentleman who presented for elective endovascular aneurysm repair (EVAR) following a routine screening scan identifying a 5.5cm abdominal aortic aneurysm (AAA). He had a past history of chronic obstructive pulmonary disease (COPD) with FEV1/FVC ratio of 48% on pre-assessment. He was hypertensive with a history of ischaemic heart disease (IHD), which has remained asymptomatic following coronary artery bypass grafting (CABG) eight years prior to this presentation. Copyright the Association for Perioperative Practice.

  15. Trends in treatment of ruptured abdominal aortic aneurysm: impact of endovascular repair and implications for future care.

    Science.gov (United States)

    Park, Brian D; Azefor, Nchang; Huang, Chun-Chih; Ricotta, John J

    2013-04-01

    Our aim was to determine national trends in treatment of ruptured abdominal aortic aneurysm (RAAA), with specific emphasis on open surgical repair (OSR) and endovascular aneurysm repair (EVAR) and its impact on mortality and complications. Data from the Nationwide Inpatient Sample (NIS) from 2005 to 2009 were queried to identify patients older than 59 years with RAAA. Three groups were studied: nonoperative (NO), EVAR, and OSR. Chi-square analysis was used to determine the relationship between treatment type and patient demographics, clinical characteristics, and hospital type. The impact of EVAR compared with OSR on mortality and overall complications was examined using logistic regression analysis. We identified 21,206 patients with RAAA from 2005 to 2009, of which 16,558 (78.1%) underwent operative repair and 21.8% received no operative treatment. In the operative group, 12,761 (77.1%) underwent OSR and 3,796 (22.9%) underwent EVAR. Endovascular aneurysm repair was more common in teaching hospitals (29.1% vs 15.2%, p < .0001) and in urban versus rural settings. Nonoperative approach was twice as common in rural versus urban hospitals. Reduced mortality was seen in patients transferred from another institutions (31.2% vs 39.4%, p = 0.014). Logistic regression analysis demonstrated a benefit of EVAR on both complication rate (OR = 0.492; CI, 0.380-0.636) and mortality (OR=0.535; CI, 0.395-0.724). Endovascular aneurysm repair use is increasing for RAAA and is more common in urban teaching hospitals while NO therapy is more common in rural hospitals. Endovascular aneurysm repair is associated with reduced mortality and complications across all age groups. Efforts to reduce mortality from RAAA should concentrate on reducing NO and OSR in patients who are suitable for EVAR. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Endovascular Repair of an Actively Hemorrhaging Stab Wound Injury to the Abdominal Aorta

    International Nuclear Information System (INIS)

    Hussain, Qasim; Maleux, Geert; Heye, Sam; Fourneau, Inge

    2008-01-01

    Traumatic injury of the abdominal aorta is rare and potentially lethal (Yeh et al., J Vasc Surg 42(5):1007-1009, 2005; Chicos et al., Chirurgia (Bucur) 102(2):237-240, 2007) as it can result in major retroperitoneal hemorrhage, requiring an urgent open surgery. In case of concomitant bowel injury or other conditions of hostile abdomen, endovascular repair can be an alternative treatment. This case report deals with a 50-year-old man presenting at the emergency ward with three stab wounds: two in the abdomen and one in the chest. During explorative laparotomy, liver laceration and bowel perforation were repaired. One day later, abdominal CT-scan revealed an additional retroperitoneal hematoma associated with an aortic pseudoaneurysm, located anteriorly 3 cm above the aortic bifurcation. Because of the risk of graft infection, an endovascular repair of the aortic injury using a Gore excluder stent-graft was performed. Radiological and clinical follow-up revealed a gradual shrinkage of the pseudo-aneurysm and no sign of graft infection at two years' follow-up.

  17. Transthoracic Echocardiography Provides Important Long-Term Prognostic Information in Selected Patients Undergoing Endovascular Abdominal Aortic Repair.

    Science.gov (United States)

    O'Driscoll, Jamie M; Bahia, Sandeep S; Gravina, Angela; Di Fino, Sara; Thompson, Matthew M; Karthikesalingam, Alan; Holt, Peter J E; Sharma, Rajan

    2016-02-01

    The value of performing transthoracic echocardiography (TTE) as part of the clinical assessment of patients awaiting endovascular repair of the abdominal aorta is little evaluated. We aimed to estimate the prognostic importance of information derived from TTE on long-term all-cause mortality in a selected group of patients undergoing endovascular aneurysm repair. This was a retrospective cohort study of 273 consecutive patients selected for endovascular aneurysm repair. All patients included in the analysis underwent TTE before their procedure. Multivariable Cox regression analysis was used to estimate the effect of TTE measures on all-cause mortality. Over a mean follow-up of 3.2±1.5 years, there were 78 deaths with a mean time to death of 1.28±1.16 years. A greater tubular ascending aorta (hazard ratio [HR] 5.6, 95% confidence interval [CI] 2.77-11.33), presence of mitral regurgitation (HR 8.13, 95% CI 4.09-12.16), lower left ventricular ejection fraction (HR 0.96, 95% CI 0.93-0.98), younger age (HR 0.97, 95% CI 0.95-0.99), and presence of diabetes mellitus (HR 1.46, 95% CI 1.24-1.89) were predictors of all-cause mortality. Echocardiography provides important long-term prognostic information in patients undergoing endovascular aneurysm repair. These TTE indices were more important at predicting outcome than standard conventional risk factors in this patient group. A greater tubular ascending aorta, presence of mitral regurgitation, reduced left ventricular ejection fraction, younger age, and diabetes mellitus were independently associated with long-term mortality. © 2016 American Heart Association, Inc.

  18. Comparison of Total Arch and Partial Arch Transposition During Hybrid Endovascular Repair for Aortic Arch Disease.

    Science.gov (United States)

    Kang, W C; Ko, Y-G; Oh, P C; Shin, E K; Park, C-H; Choi, D; Youn, Y N; Lee, D Y

    2016-08-01

    Total arch transposition (TAT) during hybrid endovascular repair for aortic arch disease is believed to allow a better landing zone, but also to be associated with higher peri-operative mortality than partial arch transposition (PAT). Information on this issue is limited. This study was a retrospective analysis. All 53 consecutive patients with aortic arch disease (41 males, mean age 65.0 years) who underwent hybrid endovascular repair with TAT (zone 0, n=20) or PAT (zone 1 or 2, n=33) from 2008 to 2014 were analyzed retrospectively. The peri-operative and late outcomes of these two groups were compared. Baseline characteristics, including EuroSCORE II results, were similar in the two groups. After procedures, peri-operative mortalities and stroke rates were similar in the two groups (5.0% vs. 9.1%, p=1.000, and 10.0% vs. 6.1%, p=.627). Interestingly, all four strokes occurred in patients with a type III aortic arch irrespective of transposition type. Primary success rates (80.0% vs. 69.7%, p=.527) and type I endoleak incidences (20.0% vs. 27.3%, p=.744) were not significantly different. During follow up (mean duration 36.9 months), overall survival (89.7% vs. 87.4% at 1 year and 89.7% vs. 79.3% at 3 years; p=.375) and re-intervention free survival rates (78.6% vs. 92.0% at 1 year; 72.0% vs. 62.2% at 3 years, p=.872) were similar in the two groups. Morbidity and mortality were high within the first year of hybrid endovascular therapy for aortic arch disease, implying that candidates for hybrid procedures need to be selected carefully. Hybrid endovascular repair with TAT was found to have peri-operative mortality, stroke, and long-term survival rates comparable with PAT, so hybrid endovascular repair may be considered, irrespective of type of arch reconstruction, when clinically indicated. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  19. The influence of prototype testing in three-dimensional aortic models on fenestrated endograft design.

    Science.gov (United States)

    Taher, Fadi; Falkensammer, Juergen; McCarte, Jamie; Strassegger, Johann; Uhlmann, Miriam; Schuch, Philipp; Assadian, Afshin

    2017-06-01

    The fenestrated Anaconda endograft (Vascutek/Terumo, Inchinnan, UK) is intended for the treatment of abdominal aortic aneurysms with an insufficient infrarenal landing zone. The endografts are custom-made with use of high-resolution, 1-mm-slice computed tomography angiography images. For every case, a nonsterile prototype and a three-dimensional (3D) model of the patient's aorta are constructed to allow the engineers as well as the physician to test-implant the device and to review the fit of the graft. The aim of this investigation was to assess the impact of 3D model construction and prototype testing on the design of the final sterile endograft. A prospectively held database on fenestrated endovascular aortic repair patients treated at a single institution was completed with data from the Vascutek engineers' prototype test results as well as the product request forms. Changes to endograft design based on prototype testing were assessed and are reported for all procedures. Between April 1, 2013, and August 18, 2015, 60 fenestrated Anaconda devices were implanted. Through prototype testing, engineers were able to identify and report potential risks to technical success related to use of the custom device for the respective patient. Theoretical concerns about endograft fit in the rigid model were expressed in 51 cases (85.0%), and the engineers suggested potential changes to the design of 21 grafts (35.0%). Thirteen cases (21.7%) were eventually modified after the surgeon's testing of the prototype. A second prototype was ordered in three cases (5.0%) because of extensive changes to endograft design, such as inclusion of an additional fenestration. Technical success rates were comparable for grafts that showed a perfect fit from the beginning and cases in which prototype testing resulted in a modification of graft design. Planning and construction of fenestrated endografts for complex aortic anatomies where exact fit and positioning of the graft are paramount to

  20. Thoracic aortic aneurysms and dissections: endovascular treatment.

    Science.gov (United States)

    Baril, Donald T; Cho, Jae S; Chaer, Rabih A; Makaroun, Michel S

    2010-01-01

    The treatment of thoracic aortic disease has changed radically with the advances made in endovascular therapy since the concept of thoracic endovascular aortic repair was first described 15 years ago. Currently, there is a diverse array of endografts that are commercially available to treat the thoracic aorta. Multiple studies, including industry-sponsored and single-institution reports, have demonstrated excellent outcomes of thoracic endovascular aortic repair for the treatment of thoracic aortic aneurysms, with less reported perioperative morbidity and mortality in comparison with conventional open repair. Additionally, similar outcomes have been demonstrated for the treatment of type B dissections. However, the technology remains relatively novel, and larger studies with longer term outcomes are necessary to more fully evaluate the role of endovascular therapy for the treatment of thoracic aortic disease. This review examines the currently available thoracic endografts, preoperative planning for thoracic endovascular aortic repair, and outcomes of thoracic endovascular aortic repair for the treatment of both thoracic aortic aneurysms and type B aortic dissections. Mt Sinai J Med 77:256-269, 2010. (c) 2010 Mount Sinai School of Medicine.

  1. Contemporary Management Strategies for Chronic Type B Aortic Dissections: A Systematic Review

    NARCIS (Netherlands)

    Kamman, Arnoud V.; de Beaufort, Hector W. L.; van Bogerijen, Guido H W; Nauta, FJH; Heijmen, Robin H.; Moll, Frans L.; van Herwaarden, Joost A.; Trimarchi, Santi

    2016-01-01

    Background Currently, the optimal management strategy for chronic type B aortic dissections (CBAD) is unknown. Therefore, we systematically reviewed the literature to compare results of open surgical repair (OSR), standard thoracic endovascular aortic repair (TEVAR) or branched and fenestrated TEVAR

  2. Percutaneous Transabdominal Approach for the Treatment of Endoleaks after Endovascular Repair of Infrarenal Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Young; Lee, Do Yun; Lee, Kwang Hun [Severance Hospital, University of Yonsei, Seoul (Korea, Republic of); Won, Jong Yun [Gangnam Severance Hospital, University of Yonsei, Seoul (Korea, Republic of); Choi, Dong Hoon; Shim, Won Heum [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2010-02-15

    The purpose of this study was to evaluate the technical feasibility and clinical efficacy of percutaneous transabdominal treatment of endoleaks after endovascular aneurysm repair. Between 2000 and 2007, six patients with type I (n = 4) or II (n = 2) endoleaks were treated by the percutaneous transabdominal approach using embolization with N-butyl cyanoacrylate with or without coils. Five patients underwent a single session and one patient had two sessions of embolization. The median time between aneurysm repair and endoleak treatment was 25.5 months (range: 0-84 months). Follow-up CT images were evaluated for changes in the size and shape of the aneurysm sac and presence or resolution of endoleaks. The median follow-up after endoleak treatment was 16.4 months (range: 0-37 months). Technical success was achieved in all six patients. Clinical success was achieved in four patients with complete resolution of the endoleak confirmed by follow-up CT. Clinical failure was observed in two patients. One eventually underwent surgical conversion, and the other was lost to follow-up. There were no procedure-related complications. The percutaneous transabdominal approach for the treatment of type I or II endoleaks, after endovascular aneurysm repair, is an alternative method when conventional endovascular methods have failed.

  3. Preoperative methylprednisolone enhances recovery after endovascular aortic repair

    DEFF Research Database (Denmark)

    de la Motte, Louise; Kehlet, Henrik; Vogt, Katja

    2014-01-01

    OBJECTIVE: To evaluate effects of preoperative high-dose glucocorticoid on the inflammatory response and recovery after endovascular aortic aneurysm repair (EVAR). BACKGROUND: The postimplantation syndrome after EVAR may delay recovery due to the release of proinflammatory mediators....... Glucocorticoids may reduce postoperative inflammatory responses and enhance recovery, but with limited information on EVAR. METHODS: A single-center, randomized, double-blind, placebo-controlled trial of 153 patients undergoing elective EVAR between November 2009 and January 2013. Patients received 30 mg.......001) and fulfillment of discharge criteria was shorter [2 days (IQR = 2-4 days) vs 3 days (IQR = 3-4 days)] (P factor receptor were also reduced (P

  4. Endovascular aneurysm repair (EVAR) follow-up imaging: the assessment and treatment of common postoperative complications

    International Nuclear Information System (INIS)

    Ilyas, S.; Shaida, N.; Thakor, A.S.; Winterbottom, A.; Cousins, C.

    2015-01-01

    Endovascular abdominal aortic aneurysm repair (EVAR) is a well-established procedure, which has long-term mortality rates similar to that of open repair. It has the additional benefit of being less invasive, making it the favoured method of treating abdominal aortic aneurysms in elderly and high-risk patients with multiple co-morbidities. The main disadvantage of EVAR is the higher rate of re-intervention, due to device-related complications, including endoleaks, limb occlusion, stent migration, kinking, and infection. As a result lifelong surveillance is required. In order to avoid missing these complications, intricate knowledge of stent graft design, good-quality diagnostic ultrasound skills, multiplanar reformatting of CT images, and reproducible investigations are important. Most of these complications can be treated via an endovascular approach using cuff extensions, uncovered stents, coils, and liquid embolic agents. Open surgery is reserved for complex complications, where an endovascular approach is not feasible. - Highlights: • Comprehensive pictorial review of EVAR related complications. • Importance of life-long EVAR surveillance, to prevent aortic rupture or lower limb ischaemia. • Identification and management of endoleaks, rupture, migration, kink/infolding, occlusion and infection

  5. Dynamic Geometric Analysis of the Renal Arteries and Aorta following Complex Endovascular Aneurysm Repair.

    Science.gov (United States)

    Ullery, Brant W; Suh, Ga-Young; Kim, John J; Lee, Jason T; Dalman, Ronald L; Cheng, Christopher P

    2017-08-01

    Aneurysm regression and target vessel patency during early and mid-term follow-up may be related to the effect of stent-graft configuration on the anatomy. We quantified geometry and remodeling of the renal arteries and aneurysm following fenestrated (F-) or snorkel/chimney (Sn-) endovascular aneurysm repair (EVAR). Twenty-nine patients (mean age, 76.8 ± 7.8 years) treated with F- or Sn-EVAR underwent computed tomography angiography at preop, postop, and follow-up. Three-dimensional geometric models of the aorta and renal arteries were constructed. Renal branch angle was defined relative to the plane orthogonal to the aorta. End-stent angle was defined as the angulation between the stent and native distal artery. Aortic volumes were computed for the whole aorta, lumen, and their difference (excluded lumen). Renal patency, reintervention, early mortality, postoperative renal impairment, and endoleak were reviewed. From preop to postop, F-renal branches angled upward, Sn-renal branches angled downward (P renals exhibited increased end-stent angulation (12 ± 15°, P renals, whereas F-renals exhibited increased end-stent angulation (5 ± 10°, P renal stent patency was 94.1% and renal impairment occurred in 2 patients (6.7%). Although F- and Sn-EVAR resulted in significant, and opposite, changes to renal branch angle, only Sn-EVAR resulted in significant end-stent angulation increase. Longitudinal geometric analysis suggests that these anatomic alterations are primarily generated early as a consequence of the procedure itself and, although persistent, they show no evidence of continued significant change during the subsequent postoperative follow-up period. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Comparative clinical effectiveness and cost effectiveness of endovascular strategy v open repair for ruptured abdominal aortic aneurysm: three year results of the IMPROVE randomised trial.

    Science.gov (United States)

    2017-11-14

    Objective  To assess the three year clinical outcomes and cost effectiveness of a strategy of endovascular repair (if aortic morphology is suitable, open repair if not) versus open repair for patients with suspected ruptured abdominal aortic aneurysm. Design  Randomised controlled trial. Setting  30 vascular centres (29 in UK, one in Canada), 2009-16. Participants  613 eligible patients (480 men) with a clinical diagnosis of ruptured aneurysm, of whom 502 underwent emergency repair for rupture. Interventions  316 patients were randomised to an endovascular strategy (275 with confirmed rupture) and 297 to open repair (261 with confirmed rupture). Main outcome measures  Mortality, with reinterventions after aneurysm repair, quality of life, and hospital costs to three years as secondary measures. Results  The maximum follow-up for mortality was 7.1 years, with two patients in each group lost to follow-up by three years. After similar mortality by 90 days, in the mid-term (three months to three years) there were fewer deaths in the endovascular than the open repair group (hazard ratio 0.57, 95% confidence interval 0.36 to 0.90), leading to lower mortality at three years (48% v 56%), but by seven years mortality was about 60% in each group (hazard ratio 0.92, 0.75 to 1.13). Results for the 502 patients with repaired ruptures were more pronounced: three year mortality was lower in the endovascular strategy group (42% v 54%; odds ratio 0.62, 0.43 to 0.88), but after seven years there was no clear difference between the groups (hazard ratio 0.86, 0.68 to 1.08). Reintervention rates up to three years were not significantly different between the randomised groups (hazard ratio 1.02, 0.79 to 1.32); the initial rapid rate of reinterventions was followed by a much slower mid-term reintervention rate in both groups. The early higher average quality of life in the endovascular strategy versus open repair group, coupled with the lower mortality at three years, led to a

  7. The influence of neck thrombus on clinical outcome and aneurysm morphology after endovascular aneurysm repair

    NARCIS (Netherlands)

    F.M.V. Bastos Gonçalves (Frederico); H.J.M. Verhagen (Hence); K. Chinsakchai (Khamin); J.W. van Keulen (Jasper); M.T. Voûte (Michiel); H.J.A. Zandvoort (Herman); F.L. Moll (Frans); J.A. van Herwaarden (Joost)

    2012-01-01

    textabstractObjective: This study investigated the influence of significant aneurysm neck thrombus in clinical and morphologic outcomes after endovascular aneurysm repair (EVAR). Methods: The patient population was derived from a prospective EVAR database from two university institutions in The

  8. Zone zero thoracic endovascular aortic repair: A proposed modification to the classification of landing zones.

    Science.gov (United States)

    Roselli, Eric E; Idrees, Jay J; Johnston, Douglas R; Eagleton, Matthew J; Desai, Milind Y; Svensson, Lars G

    2018-04-01

    Endovascular stent-grafting provides an alternative treatment option for high-risk patients with ascending aortic disease. The feasibility of this approach has been demonstrated before. We assess the updated experience with ascending thoracic endovascular aortic repair and propose a modification of the landing zone classification based on the outcomes. From 2006 to 2016, 39 patients deemed very high risk for open replacement underwent endovascular repair of ascending aorta for acute type A dissection (12, 31%), intramural hematoma (2, 5%), pseudoaneurysm (22, 56%), and chronic dissection suture line entry tear (3, 8%). Ascending thoracic endovascular aortic repair was performed in 36 patients. In 3 patients with pseudoaneurysm, occluder devices were used. Computed tomography imaging analysis was performed, and the extent of aortic pathology was designated by segmental proximity to the left ventricle. Segmental anatomy of the proximal aorta was designed as zone 0A from the annulus to the distal margin of highest coronary, 0B extends from above the coronary to the distal margin of right pulmonary artery, and 0C extends from the right pulmonary artery border to the innominate artery. Multivariable time to event Cox regression analysis was performed to predict mortality, and long-term survival was estimated using the Kaplan-Meier method. Operative mortality was 13%; all 5 deaths occurred after emergency ascending thoracic endovascular aortic repair for type A dissection. Other complications included stroke in 4 patients (10%), myocardial infarction in 2 patients (5%), tracheostomy in 2 patients (5%), and dialysis in 2 patients (5%). In patients with acute type A dissection, the ascending pathology extended into zone 0A in 10 (71%) and 0B in 4 (29%). Among those with pseudoaneurysm, the location of the defect was in 0B in 11 (50%), 0C in 10 (45%), and 0A in 1. Among the patients with chronic dissection, the defect was located in 0C in all 3 (100%). After multivariable

  9. Endovascular Retrieval of Entrapped Elephant Trunk Graft During Complex Hybrid Aortic Arch Repair

    Energy Technology Data Exchange (ETDEWEB)

    Damodharan, Karthikeyan, E-mail: drdkarthik@hotmail.com [Singapore General Hospital, Department of Diagnostic Radiology (Singapore); Chao, Victor T. T., E-mail: victor.chao.t.t@singhealth.com.sg [National Heart Centre, Department of Cardiothoracic Surgery (Singapore); Tay, Kiang Hiong, E-mail: tay.kiang.hiong@singhealth.com.sg [Singapore General Hospital, Department of Diagnostic Radiology (Singapore)

    2016-12-15

    Entrapment of the elephant trunk graft within the false lumen is a rare complication of surgical repair of an aortic dissection. This is normally retrieved by emergent open surgery. We describe a technique of endovascular retrieval of the dislodged graft, during hybrid aortic arch repair. The elephant trunk was cannulated through and through from a femoral access and the free end of the wire was snared and retrieved from a brachial access. The wire was externalised from both accesses and was used to reposition the graft into the true lumen using a body flossing technique.

  10. Evolution of the Proximal Sealing Rings of the Anaconda Stent-Graft After Endovascular Aneurysm Repair

    NARCIS (Netherlands)

    Koenrades, Maaike A.; Klein, Almar; Leferink, Anne M.; Slump, Cornelis H.; Geelkerken, Robert H.

    2018-01-01

    Purpose: To provide insight into the evolution of the saddle-shaped proximal sealing rings of the Anaconda stent-graft after endovascular aneurysm repair (EVAR). Methods: Eighteen abdominal aortic aneurysm patients were consecutively enrolled in a single-center, prospective, observational cohort

  11. Statin use is associated with reduced all-cause mortality after endovascular abdominal aortic aneurysm repair.

    NARCIS (Netherlands)

    Leurs, L.J.; Visser, P.; Laheij, R.J.F.; Buth, J.; Harris, P.L.; Blankensteijn, J.D.

    2006-01-01

    It has been shown that preoperative statin therapy reduces all-cause and cardiovascular mortality in patients undergoing major noncardiac vascular surgery. In this report, we investigated the influence of statin use on early and late outcome following endovascular abdominal aortic aneurysm repair

  12. Retrograde ascending aortic dissection during or after thoracic aortic stent graft placement: insight from the European registry on endovascular aortic repair complications

    DEFF Research Database (Denmark)

    Eggebrecht, Holger; Thompson, Matt; Rousseau, Hervé

    2009-01-01

    BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic...

  13. Emergency abdominal aortic aneurysm repair with a preferential endovascular strategy : Mortality and cost-effectiveness analysis

    NARCIS (Netherlands)

    Kapma, Marten R.; Groen, Henk; Oranen, Bjorn I.; van der Hilst, Christian S.; Tielliu, Ignace F.; Zeebregts, Clark J.; Prins, Ted R.; van den Dungen, Jan J.; Verhoeven, Eric L.

    2007-01-01

    Purpose: To assess mortality and treatment costs of a new management protocol with preferential use of emergency endovascular aneurysm repair (eEVAR) for acute abdominal aortic aneurysm (AAA). Methods: From September 2003 until February 2005, 49 consecutive patients (45 men; mean age 71 years) with

  14. Endovascular repair of arterial iliac vessel wall lesions with a self-expandable nitinol stent graft system.

    Directory of Open Access Journals (Sweden)

    Birger Mensel

    Full Text Available To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs using a self-expandable Nitinol stent graft system.Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications.The primary technical and clinical success rate was 81.3% (13/16 patients and 75.0% (12/16, respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16 and 93.8% (15/16. The minor complication rate was 6.3% (patient with painful hematoma at the access site. The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis. During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed.Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.

  15. Supra-aortic interventions for endovascular exclusion of the entire aortic arch.

    Science.gov (United States)

    Andrási, Terézia B; Grossmann, Marius; Zenker, Dieter; Danner, Bernhard C; Schöndube, Friedrich A

    2017-07-01

    Our aim was to analyze the outcomes of endovascular exclusion of the entire aortic arch (proximal landing in zone 0, distal landing in zone III or beyond, after Ishimaru) in which complete surgical debranching of the supra-aortic vessels (I), endovascular supra-aortic revascularization (chimney, fenestrated, or branched grafts) with partial surgical debranching (II), or total endovascular supra-aortic revascularization (III) was additionally performed. Publications describing endovascular repair of the aortic arch (2000-2016) were systematically searched and reviewed. From a total of 53 relevant studies including 1853 patients, only 1021 patients undergoing 35 different total aortic arch procedures were found eligible for further evaluation and included in group I, II, or III (429, 190, and 402 patients, respectively). Overall early mortality was higher in group I vs groups II and III (P = .001; 1 - β = 95.6%) but exceeded in group III (18.6%) and group II (14.0%) vs group I (8.0%; P = .044; 1 - β = 57.4%) for diseases involving zone 0. Mortality was higher in all subgroups treated for zone 0 disease compared with corresponding subgroups treated for zone I to zone III disease. The incidence of cerebral ischemic events was increased in groups I and II vs group III (7.5% and 11% vs 1.7%; P = .0001) and correlated with early mortality (R 2  = .20; P = .033). The incidence of type II endoleaks and endovascular reintervention was similar between groups and correlated with each other (R 2  = .37; P = .004). Type Ia endoleak occurred more often in groups II and III than in group I (7.1% and 12.1% vs 5.8%; P = .023) and correlated with midterm mortality (R 2  = .53; P = .005). Retrograde type A dissection was low in all groups, whereas aneurysm growth was higher in group III (2.6%, 4.2%, 10.7%; P = .002), correlating with midterm mortality (R 2  = .311; P = .009). Surgical revision slightly correlated with surgical complications (R 2  = .18; P = .044

  16. Endovascular abdominal aortic aneurysm repair (EVAR) procedures: counterbalancing the benefits with the costs.

    Science.gov (United States)

    Paraskevas, Kosmas I; Bessias, Nikolaos; Giannoukas, Athanasios D; Mikhailidis, Dimitri P

    2010-05-01

    Endovascular abdominal aortic aneurysm (AAA) repair (EVAR) is associated with lower 30-day mortality rates compared with open repair. Despite that, there are no significant differences in mortality rates between the two procedures at 2 years. On the other hand, EVAR is associated with considerably higher costs compared with open repair. The lack of significant long-term differences between the two procedures together with the substantially higher cost of EVAR may question the appropriateness of EVAR as an alternative to open surgical repair in patients fit for surgery. With several thousands of AAA procedures performed worldwide, the employment of EVAR for the management of all AAAs irrespective of the patient's surgical risk may hold implications for several national health economies. The lower perioperative mortality and morbidity rates associated with EVAR should thus be counterbalanced against the considerable costs of these procedures.

  17. Geometric Deformations of the Thoracic Aorta and Supra-Aortic Arch Branch Vessels Following Thoracic Endovascular Aortic Repair.

    Science.gov (United States)

    Ullery, Brant W; Suh, Ga-Young; Hirotsu, Kelsey; Zhu, David; Lee, Jason T; Dake, Michael D; Fleischmann, Dominik; Cheng, Christopher P

    2018-04-01

    To utilize 3-D modeling techniques to better characterize geometric deformations of the supra-aortic arch branch vessels and descending thoracic aorta after thoracic endovascular aortic repair. Eighteen patients underwent endovascular repair of either type B aortic dissection (n = 10) or thoracic aortic aneurysm (n = 8). Computed tomography angiography was obtained pre- and postprocedure, and 3-D geometric models of the aorta and supra-aortic branch vessels were constructed. Branch angle of the supra-aortic branch vessels and curvature metrics of the ascending aorta, aortic arch, and stented thoracic aortic lumen were calculated both at pre- and postintervention. The left common carotid artery branch angle was lower than the left subclavian artery angles preintervention ( P Supra-aortic branch vessel angulation remains relatively static when proximal landing zones are distal to the left common carotid artery.

  18. The effect of endograft device on patient outcomes in endovascular repair of ruptured abdominal aortic aneurysms.

    Science.gov (United States)

    Kansal, Vinay; Nagpal, Sudhir; Jetty, Prasad

    2017-12-01

    Objective Endovascular aneurysm repair for ruptured abdominal aortic aneurysm is being increasingly applied as the intervention of choice. The purpose of this study was to determine whether survival and reintervention rates after ruptured abdominal aortic aneurysm vary between endograft devices. Methods This cohort study identified all ruptured abdominal aortic aneurysms performed at The Ottawa Hospital from January 1999 to May 2015. Data collected included patient demographics, stability index at presentation, adherence to device instructions for use, endoleaks, reinterventions, and mortality. Kruskal-Wallis test was used to compare outcomes between groups. Mortality outcomes were assessed using Kaplan-Meier survival analysis, and multivariate Cox regression modeling. Results One thousand sixty endovascular aneurysm repairs were performed using nine unique devices. Ninety-six ruptured abdominal aortic aneurysms were performed using three devices: Cook Zenith ( n = 46), Medtronic Endurant ( n = 33), and Medtronic Talent ( n = 17). The percent of patients presented in unstable or extremis condition was 30.2, which did not differ between devices. Overall 30-day mortality was 18.8%, and was not statistically different between devices ( p = 0.16), although Medtronic Talent had markedly higher mortality (35.3%) than Cook Zenith (15.2%) and Medtronic Endurant (15.2%). AUI configuration was associated with increased 30-day mortality (33.3% vs. 12.1%, p = 0.02). Long-term mortality and graft-related reintervention rates at 30 days and 5 years were similar between devices. Instructions for use adherence was similar across devices, but differed between the ruptured abdominal aortic aneurysm and elective endovascular aneurysm repair cohorts (47.7% vs. 79.0%, p 30 days post-endovascular aneurysm repair ( p = 0.01). Type 1 endoleak rates differed significantly across devices (Cook Zenith 0.0%, Medtronic Endurant 18.2%, Medtronic Talent 17.6%, p = 0

  19. [Outcomes of endovascular repairing aortic arch disease hybrid with supra-arch debranching procedures].

    Science.gov (United States)

    Wang, Mian; Chang, Guangqi; Yin, Henghui; Yao, Chen; Wang, Jinsong; Wang, Shenming

    2015-11-01

    To summarize the experience of endovascular repairing aortic arch disease hybrid with supra-arch debranching procedures. It was a retrospective study. From January 2002 to December 2014, 42 high risk patients with aortic arch disease were treated by supra-arch debranching hybrid with subsequent endovascular repair in the First Affiliated Hospital of Sun Yat-sen University. There were 39 male and 3 female patients with a mean age of (53±13) years (ranging from 34 to 80 years). Of the 42 patients, 7 were thoracic aortic aneurysm, 20 were Stanford type B aortic dissection and 15 were Stanford type A aortic dissection. After the supra-aortic debranching technique, simultaneous (n=16) or staged (n=26, mean interval (7±3) days) endovascular repair were performed. Fisher exact test was used to compare the in-hospital mortality of ascending aorta based debranching and non-ascending aorta based debranching. Technical success rate was 81.0% (34/42). The overall 30-day complication rate was 31.0% (13/42), including 3 cerebral stroke (7.1%), 8 endoleak (19.0%, including 6 type I endoleak and 2 type II endoleak), 1 circulatory failure, 1 aorto-tracheal fistula. The 30-day mortality was 9.5% (4/42), 2 died of cerebral stroke, 1 died of circulatory failure, 1 died of aorto-tracheal fistula. The in-hospital mortality of ascending aorta based debranching group was obviously higher than that of the non-ascending aorta based debranching group (4/16 vs. 0, P=0.02). The median time of follow-up was 64.8 (2 to 156.9) months. CT scanning was performed at 1, 3 months after surgery and annually thereafter. The overall survival rate was 76.6%. During the follow-up period, there was 4 deaths, and 2 of them were aortic artery related (5.3%). There were 4 de novo complications during the follow-up period, 1 stroke attributed to bypass occlusion was cured by medical treatment, 2 pseudoaneurysm was successfully treated with open surgery, 1 stent-graft induced new distal entry tear was

  20. Spinal arterial anatomy and risk factors for lower extremity weakness following endovascular thoracoabdominal aortic aneurysm repair with branched stent-grafts.

    Science.gov (United States)

    Chang, Catherine K; Chuter, Timothy A M; Reilly, Linda M; Ota, Maile K; Furtado, Andre; Bucci, Monica; Wintermark, Max; Hiramoto, Jade S

    2008-06-01

    To evaluate spinal arterial anatomy and identify risk factors for lower extremity weakness (LEW) following endovascular thoracoabdominal aortic aneurysm (TAAA) repair. A retrospective review was conducted of 37 patients (27 men; mean age 74.8+/-7.1 years, range 58-86) undergoing endovascular TAAA repair with branched stent-grafts at a single academic institution from July 2005 to December 2007. Data were collected on preoperative comorbidities, duration of operation, blood loss, type of anesthesia, extent of aortic coverage, blood pressure, cerebrospinal fluid (CSF) pressure and drainage, and postoperative development of LEW. Pre- and postoperative contrast-enhanced computed tomographic angiograms (CTA) in a 26-patient subset were analyzed to evaluate the number of patent intercostal and lumbar arteries before and after repair. All patients were neurologically intact at the end of the operation. Seven (19%) patients developed LEW postoperatively: 6 perioperatively and 1 after discharge. LEW was associated with postoperative hypotension, internal iliac artery (IIA) occlusion, and fewer patent segmental arteries on preoperative CTA. Lowest mean systolic blood pressure was segmental arteries in patients with or without LEW. Endovascular TAAA repair inevitably occludes direct inflow to lumbar and intercostal arteries. The distal segments of these arteries to the spine, however, are seen to remain patent through collaterals. Measures to preserve collateral pathways and increase perfusion pressure may help prevent or treat LEW.

  1. A Matched Case-Control Study on Open and Endovascular Treatment of Popliteal Artery Aneurysms.

    Science.gov (United States)

    Dorigo, W; Fargion, A; Masciello, F; Piffaretti, G; Pratesi, G; Giacomelli, E; Pratesi, C

    2018-01-01

    To compare early and late results of open and endovascular management of popliteal artery aneurysm in a retrospective single-center matched case-control study Methods: From 1981 to 2015, 309 consecutive interventions for popliteal artery aneurysm were performed in our institution, in 59 cases with endovascular repair and in 250 cases with open repair. Endovascular repair was preferred in older asymptomatic patients, while open repair was offered more frequently to patients with a thrombosed popliteal artery aneurysm and a poor run-off status. A one-to-one coarsened exact matching on the basis of the baseline demographic, clinical, and anatomical covariates significantly different between the two treatment options was performed and two equivalent groups of 56 endovascular repairs and open repairs were generated. The two groups were compared in terms of perioperative results with χ 2 test and of follow-up outcomes with the Kaplan-Meier curves and log-rank test. There were no differences between the two groups in terms of perioperative outcomes. Median duration of follow-up was 38 months. Five-year survival rates were 94% in endovascular repair group and 89.5% in open repair group (p = 0.4, log-rank 0.6). Primary patency rates at 1, 3, and 5 years were 81%, 78%, and 72% in endovascular repair group and 82.5%, 80%, and 64% in open repair group (p = 0.8, log-rank 0.01). Freedom from reintervention at 5 years was 65.5% in endovascular repair group and 76% in open repair group (p = 0.2, log-rank 1.2). Secondary patency at 1, 3, and 5 years was 94%, 86%, and 74% in endovascular repair group, and 94%, 89%, and 71% in open repair group, respectively (p = 0.9, log-rank 0.01). The rates of limb preservation at 5 years were 94% in endovascular repair group and 86.4% in open repair group (p = 0.3, log-rank 0.8). Open repair and endovascular repair of popliteal artery aneurysms provided in this retrospective single-center experience similar perioperative and follow-up results in

  2. Endovascular Repair of a Pseudoaneurysm of the Abdominal Aorta Secondary to Translumbar Aortography

    International Nuclear Information System (INIS)

    Mir, Naheed; Nunzio, Mario De; Pollock, John G

    2006-01-01

    This report describes an incidental finding of a pseudoaneurysm of the abdominal aorta on a computed tomography (CT) renal angiogram during investigation of chronic renal failure in a 73-year-old man. The patient had undergone a translumbar aortogram 20 years previously. An increase in the size of the aneurysm by 7 mm over 6 months prompted treatment and the aneurysm underwent successful endovascular repair with a custom-made stent-graft

  3. Periprocedural and long-term outcomes of endovascular abdominal aortic aneurysm repair in cardiology practice.

    Science.gov (United States)

    Basoor, Abhijeet; Patel, Kiritkumar C; Halabi, Abdul R; Todorov, Mina; Senthilvadivel, Prashanth; Choksi, Nishit; Phan, Thanh; LaLonde, Thomas; Yamasaki, Hiroshi; DeGregorio, Michele

    2014-12-01

    Endovascular repair of abdominal aortic aneurysm (AAA) has recently been made a class I indication in the treatment of AAA. In comparison to the conventional open surgical treatment, endovascular AAA repair (EVAR) is associated with equivalent long-term morbidity and mortality rates. Vascular surgeons perform majority of EVAR. There are no reports for the long-term results of this intervention performed by interventional cardiologists. We present one of the first reports of periprocedural and long-term outcomes of EVAR performed by interventional cardiologists. Retrospective chart review on patients with attempted EVAR between September 2005 and January 2011 was performed. Included cases were all consecutive patients who had attempted EVAR by interventional cardiologists. During the study period EVAR was attempted in 170 patients, with 27% being women. The mean age was 74 years (range 52-93). The endovascular graft placement was successful in 96% (163/170) of patients. Procedure failures were more common in women (6 of 46 vs 1 of 124, P = 0.003). The 30-day mortality was 1.8 % (3 of 170). In patients with successful EVAR the mean follow-up was 30 months and mean length of hospital stay was 3.5 ± 3.2 days. Major periprocedural complications were noted in 9% patients (15 of 167). During follow-up, six patients (3.5%) required re-intervention and additional 16 patients died with no aneurysm related deaths. EVAR primarily performed by interventional cardiologists demonstrates high periprocedural and long-term success rates. A higher EVAR failure rate has been observed in women. © 2014 Wiley Periodicals, Inc.

  4. [Endovascular surgery in the war].

    Science.gov (United States)

    Reva, V A; Samokhvalov, I M

    2015-01-01

    Rapid growth of medical technologies has led to implementation of endovascular methods of diagnosis and treatment into rapidly developing battlefield surgery. This work based on analysing all available current publications generalizes the data on using endovascular surgery in combat vascular injury. During the Korean war (1950-1953) American surgeons for the first time performed endovascular balloon occlusion of the aorta - the first intravascular intervention carried out in a zone of combat operations. Half a century thereafter, with the beginning of the war in Afghanistan (2001) and in Iraq (2003) surgeons of central hospitals of the USA Armed Forces began performing delayed endovascular operations to the wounded. The development of technologies, advent of mobile angiographs made it possible to later on implement high-tech endovascular interventions in a zone of combat operations. At first, more often they performed implantation of cava filters, somewhat afterward - angioembolization of damaged accessory vessels, stenting and endovascular repair of major arteries. The first in the theatre of war endovascular prosthetic repair of the thoracic aorta for severe closed injury was performed in 2008. Russian experience of using endovascular surgery in combat injuries is limited to diagnostic angiography and regional intraarterial perfusion. Despite the advent of stationary angiographs in large hospitals of the RF Ministry of Defence in the early 1990s, endovascular operations for combat vascular injury are casuistic. Foreign experience in active implementation of endovascular technologies to treatment of war-time injuries has substantiated feasibility of using intravascular interventions in tertiary care military hospitals. Carrying out basic training courses on endovascular surgery should become an organic part of preparing multimodality general battlefield surgeons rendering care on the theatre of combat operations.

  5. Can an accessory renal artery be safely covered during endovascular aortic aneurysm repair?

    OpenAIRE

    Antoniou, George A.; Karkos, Christos D.; Antoniou, Stavros A.; Georgiadis, George S.

    2013-01-01

    A best evidence topic was constructed according to a structured protocol. The question addressed was whether coverage of an accessory renal artery (ARA) in patients undergoing endovascular aortic aneurysm repair (EVAR) is associated with increased risk of renal impairment. Altogether, 106 papers were located using the reported searches, of which 5 represented the best evidence to answer the question. The authors, journal, date and country of publication, study type, patient group studied, rel...

  6. A geometric reappraisal of proximal landing zones for thoracic endovascular aortic repair according to aortic arch types

    NARCIS (Netherlands)

    Marrocco-Trischitta, Massimiliano M.; de Beaufort, Hector W.; Secchi, Francesco; van Bakel, Theodorus M.; Ranucci, Marco; van Herwaarden, Joost A.; Moll, Frans L.; Trimarchi, Santi

    Objective: This study assessed whether the additional use of the aortic arch classification in type I, II, and III may complement Ishimaru's aortic arch map and provide valuable information on the geometry and suitability of proximal landing zones for thoracic endovascular aortic repair. Methods:

  7. Outcome after open surgery repair in endovascular-suitable patients with ruptured abdominal aortic aneurysms.

    Science.gov (United States)

    Krenzien, Felix; Matia, Ivan; Wiltberger, Georg; Hau, Hans-Michael; Freitas, Bruno; Moche, Michael; Schmelzle, Moritz; Jonas, Sven; Fellmer, Peter T

    2013-11-01

    Endovascular aneurysm repair (EVAR) has been suggested in several studies to be superior to open surgery repair (OSR) for the treatment of ruptured abdominal aortic aneurysms (rAAAs), but this finding might be affected by selection bias based on aneurysm morphology and patient characteristics. We tested rAAA anatomy according to EVAR suitability in patients undergoing OSR to assess the impact on mortality. This retrospective analysis reports on 83 patients with rAAAs treated between November 2002 and July 2013. Pre-operative computed tomography (CT) scans were evaluated based on EVAR suitability and were determined by blinded independent reviewers. CT scans were lacking due to acquisition in an external institution with no availability (n = 9) or solely ultrasound evaluations (n = 8). In addition patient characteristics and outcomes were assessed. All patients who underwent OSR and who had available preoperative CT scans were included in the study (n = 66). In summary, 42 % of the patients (28/66; 95 % confidence interval [CI], 30.5 - 54.4) were considered eligible for EVAR according to pre-operative CT scans and 58 % of the patients (38/66; 95 % CI, 45.6 - 69.5) were categorized as unsuitable for endovascular repair. Patients suitable for EVAR had a significantly lower prevalence of in-hospital deaths (25 % [7/28]; 95 % CI, 9 - 41) in contrast to patients unsuitable for EVAR (53 % [20/38]; 95 % CI, 36.8 - 68.5; p = 0.02). EVAR-suitable patients had a highly significant mortality reduction undergoing OSR. Thus, the present study proposes that EVAR suitability is a positive predictor for survival after open repair of rAAA.

  8. A prospective clinical, economic, and quality-of-life analysis comparing endovascular aneurysm repair (EVAR), open repair, and best medical treatment in high-risk patients with abdominal aortic aneurysms suitable for EVAR: the Irish patient trial.

    LENUS (Irish Health Repository)

    Hynes, Niamh

    2007-12-01

    To report the results of a trial comparing endovascular aneurysm repair (EVAR) to open repair (OR) and best medical therapy (BMT) involving high-risk patients with abdominal aortic aneurysms (AAA) suitable for EVAR.

  9. Endovascular repair of an aorto-iliac aneurysm succeeded by kidney transplantation Tratamento endovascular de aneurisma aorto-ilíaco sucedido por transplante renal

    Directory of Open Access Journals (Sweden)

    Marcelo Bellini Dalio

    2010-09-01

    Full Text Available We present the case of aorto-iliac aneurysm in a patient with chronic renal failure requiring dialysis who were treated with an endovascular stent graft and, later on, submitted to kidney transplantation. A 53-year-old male with renal failure requiring dialysis presented with an asymptomatic abdominal aorto-iliac aneurysm measuring 5.0cm of diameter. He was treated with endovascular repair technique, being used an endoprosthesis Excluder®. After four months, he was successfully submitted to kidney transplantation (dead donor, with anastomosis of the graft renal artery in the external iliac artery distal to the endoprosthesis. The magnetic resonance imaging, carried out 30 days after the procedure, showed a good positioning of the endoprosthesis and adequate perfusion of the renal graft. In the follow-up, the patient presented improvement of nitrogenous waste, good positioning of the endoprosthesis without migration or endoleak. The endovascular repair of aorto-iliac aneurysm in a patient with end-stage renal failure under hemodialysis treatment showed to be feasible, safe and efficient, as it did not prevent the success of the posterior kidney transplantation.Apresentamos o caso de aneurisma aortoilíaco em um paciente com insuficiência renal crônica dialítica tratado com uma endoprótese vascular, sendo, após, submetido a transplante renal. Um homem de 53 anos com insuficiência renal dialítica apresentava um aneurisma abdominal aortoilíaco assintomático com 5,0cm de diâmetro. Foi tratado com técnica endovascular com uma endoprótese Excluderâ. Após quatro meses, foi submetido a transplante renal (doador cadáver com sucesso, com anastomose da artéria renal do enxerto na artéria ilíaca externa distal à endoprótese. A ressonância magnética 30 dias após o procedimento mostrou a endoprótese bem posicionada e o enxerto renal bem perfundido. No seguimento, o paciente evoluiu com melhora das escórias nitrogenadas, bom

  10. Decision-making in follow-up after endovascular aneurysm repair based on diameter and volume measurements : a blinded comparison

    NARCIS (Netherlands)

    Prinssen, M; Verhoeven, ELG; Verhagen, HJM; Blankensteijn, JD

    Objective: to assess whether volume, in addition to diameter, measurements facilitate decision-making after endovascular aneurysm repair (EVAR). Material/Methods: patients (n = 82) with an immediately post-EVAR, and at least one follow-up (3-60 months), computed tomographic angiogram (CTA) were

  11. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    International Nuclear Information System (INIS)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha

    2016-01-01

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  12. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha, E-mail: alex_cantador@yahoo.com.br [Universidade Estadual de Campinas (FCM/UNICAMP), Campinas, SP (Brazil). Faculdade de Ciencias Medicas

    2016-07-15

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  13. Endovascular repair of traumatic thoracic aortic tears.

    Science.gov (United States)

    Mansour, M Ashraf; Kirk, Jeffrey S; Cuff, Robert F; Banegas, Shonda L; Ambrosi, Gavin M; Liao, Timothy H; Chambers, Christopher M; Wong, Peter Y; Heiser, John C

    2012-03-01

    Patients with thoracic aorta injuries (TAI) present a unique challenge. The purpose of this study was to review the outcomes of thoracic endovascular aortic repair (TEVAR) in patients with TAI. A retrospective chart review of all patients admitted for TEVAR for trauma was performed. In a 5-year period, 19 patients (6 women and 13 men; average age, 42 y) were admitted to our trauma center with TAI. Mechanism of injury was a motor vehicle crash in 12 patients, motorcycle crash in 2 patients, automobile-pedestrian accident in 2 patients, 1 fall, 1 crush injury, and 1 stab wound to the back. A thoracic endograft was used in 6 patients and proximal aortic cuffs were used in 13 patients (68%). One patient (5%) died. There were no strokes, myocardial infarctions, paraplegia, or renal failure. TEVAR for TAI appears to be a safe option for patients with multiple injuries. TEVAR in young patients is still controversial because long-term endograft behavior is unknown. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Endovascular repair of abdominal aortic aneurysms: vascular anatomy, device selection, procedure, and procedure-specific complications.

    Science.gov (United States)

    Bryce, Yolanda; Rogoff, Philip; Romanelli, Donald; Reichle, Ralph

    2015-01-01

    Abdominal aortic aneurysm (AAA) is abnormal dilatation of the aorta, carrying a substantial risk of rupture and thereby marked risk of death. Open repair of AAA involves lengthy surgery time, anesthesia, and substantial recovery time. Endovascular aneurysm repair (EVAR) provides a safer option for patients with advanced age and pulmonary, cardiac, and renal dysfunction. Successful endovascular repair of AAA depends on correct selection of patients (on the basis of their vascular anatomy), choice of the correct endoprosthesis, and familiarity with the technique and procedure-specific complications. The type of aneurysm is defined by its location with respect to the renal arteries, whether it is a true or false aneurysm, and whether the common iliac arteries are involved. Vascular anatomy can be divided more technically into aortic neck, aortic aneurysm, pelvic perfusion, and iliac morphology, with grades of difficulty with respect to EVAR, aortic neck morphology being the most common factor to affect EVAR appropriateness. When choosing among the devices available on the market, one must consider the patient's vascular anatomy and choose between devices that provide suprarenal fixation versus those that provide infrarenal fixation. A successful technique can be divided into preprocedural imaging, ancillary procedures before AAA stent-graft placement, the procedure itself, postprocedural medical therapy, and postprocedural imaging surveillance. Imaging surveillance is important in assessing complications such as limb thrombosis, endoleaks, graft migration, enlargement of the aneurysm sac, and rupture. Last, one must consider the issue of radiation safety with regard to EVAR. (©)RSNA, 2015.

  15. Endovascular Treatment of Late Thoracic Aortic Aneurysms after Surgical Repair of Congenital Aortic Coarctation in Childhood

    Science.gov (United States)

    Juszkat, Robert; Perek, Bartlomiej; Zabicki, Bartosz; Trojnarska, Olga; Jemielity, Marek; Staniszewski, Ryszard; Smoczyk, Wiesław; Pukacki, Fryderyk

    2013-01-01

    Background In some patients, local surgery-related complications are diagnosed many years after surgery for aortic coarctation. The purposes of this study were: (1) to systematically evaluate asymptomatic adults after Dacron patch repair in childhood, (2) to estimate the formation rate of secondary thoracic aortic aneurysms (TAAs) and (3) to assess outcomes after intravascular treatment for TAAs. Methods This study involved 37 asymptomatic patients (26 female and 11 male) who underwent surgical repair of aortic coarctation in the childhood. After they had reached adolescence, patients with secondary TAAs were referred to endovascular repair. Results Follow-up studies revealed TAA in seven cases (19%) (including six with the gothic type of the aortic arch) and mild recoarctation in other six (16%). Six of the TAA patients were treated with stentgrafts, but one refused to undergo an endovascular procedure. In three cases, stengrafts covered the left subclavian artery (LSA), in another the graft was implanted distally to the LSA. In two individuals, elective hybrid procedures were performed with surgical bypass to the supraaortic arteries followed by stengraft implantation. All subjects survived the secondary procedures. One patient developed type Ia endoleak after stentgraft implantation that was eventually treated with a debranching procedure. Conclusions The long-term course of clinically asymptomatic patients after coarctation patch repair is not uncommonly complicated by formation of TAAs (particularly in individuals with the gothic pattern of the aortic arch) that can be treated effectively with stentgrafts. However, in some patients hybrid procedures may be necessary. PMID:24386233

  16. Perioperative management of endovascular abdominal aortic aneurysm repair

    International Nuclear Information System (INIS)

    Wang Haofu; Wang Yuwei; Li Jun; Zhao Zonggang; Qi Sen

    2010-01-01

    Objective: To summarize the clinical experience of perioperative management in performing endovascular abdominal aortic aneurysm repair (EVAR). Methods: EVAR was performed in 22 patients with abdominal aortic aneurysm. The clinical data were retrospectively analyzed. Before treatment the functions of main organs were evaluated and certain measures were adopted in order to protect them. Useful parameters, including the length, diameter, angle and configuration of the proximal and distal aneurysmal neck, the relationship of the aneurysm to aortic branches, the distance from the lowest renal artery to the bifurcation of abdominal aorta, and the quality of access vessels (such as diameter, tortuosity and calcification degree) were determined and assessed with CTA. According to the parameters thus obtained, the suitable stent-graft with ideal diameter and length was selected, and the optimal surgery pattern was employed. Local anesthesia was employed in 20 patients, among them the local anesthesia had to be changed to general anesthesia in one. Epidural anesthesia was carried out in one patient through the surgically-reconstructed iliac artery access,and general anesthesia was employed in one patient who had Stanford type A aortic dissection. The lowest renal artery must be accurately localized before deployment of stent-graft was started. At least one patent internal iliac artery should be reserved when bilateral internal iliac arteries needed to be covered, to be covered by stages or to be reconstructed. After stent-graft placement, angiography must be performed to find out if there was any endoleak and, if any, to determine the type of endoleak and to deal with it properly. Two cases had proximal type I endoleak, so balloon dilation was employed in one and cuff implantation in another one. Distal type I endoleak occurred in one case, but, unfortunately, the iliac artery ruptured when balloon dilation was employed, therefore the patient had to receive vascular repair

  17. Logistic considerations for a successful institutional approach to the endovascular repair of ruptured abdominal aortic aneurysms.

    Science.gov (United States)

    Mayer, Dieter; Rancic, Zoran; Pfammatter, Thomas; Hechelhammer, Lukas; Veith, Frank J; Donas, Konstantin; Lachat, Mario

    2010-01-01

    The value of emergency endovascular aneurysm repair (EVAR) in the setting of ruptured abdominal aortic aneurysm remains controversial owing to differing results. However, interpretation of published results remains difficult as there is a lack of generally accepted protocols or standard operating procedures. Furthermore, such protocols and standard operating procedures often are reported incompletely or not at all, thereby making interpretation of results difficult. We herein report our integrated logistic system for the endovascular treatment of ruptured abdominal aortic aneurysms. Important components of this system are prehospital logistics, in-hospital treatment logistics, and aftercare. Further studies should include details about all of these components, and a description of these logistic components must be included in all future studies of emergency EVAR for ruptured abdominal aortic aneurysms.

  18. Is Conventional Open Repair for Abdominal Aortic Aneurysm Feasible in Nonagenarians?

    Science.gov (United States)

    Uehara, Kyokun; Matsuda, Hitoshi; Inoue, Yosuke; Omura, Atsushi; Seike, Yoshimasa; Sasaki, Hiroaki; Kobayashi, Junjiro

    2017-09-25

    Background : Although endovascular repair for abdominal aortic aneurysm has been found to be beneficial in very elderly patients, some patients have contraindications to this procedure. For nonagenarians, the results of open repair remain unclear. The purpose of this study was to compare the outcomes of open vs. endovascular repair for abdominal aortic aneurysm in nonagenarian patients. Methods and Results : Fourteen patients undergoing open surgical repair and 24 undergoing endovascular repair for abdominal aortic aneurysm were evaluated. There was no significant difference in early mortality between the open and endovascular groups (0% vs. 4.1%, p=0.16). The open repair group required much longer hospital stays (26.4 vs. 10.6 days, respectively, p=0.003). Finally, 12 patients (86%) undergoing open repair vs. 21 (88%) undergoing endovascular repair returned home (p=0.49). During a mean follow-up period of 23.4±23.5 months, cumulative estimated 1- and 3-year survival rates were 90.0% and 48.0%, respectively in the open repair group and 90.6% and 54.9%, respectively in the endovascular repair group (p=0.51). Conclusion : Although endovascular repair for abdominal aortic aneurysm was superior in terms of recovery, the results of conventional open repair were acceptable even in nonagenarian patients. Open repair remains an alternative for patients with contraindications to endovascular repair.

  19. Endovascular Repair of Abdominal Aortic Aneurysms in the Presence of a Transplanted Kidney

    International Nuclear Information System (INIS)

    Silverberg, Daniel; Yalon, Tal; Halak, Moshe

    2015-01-01

    PurposeTo present our experience performing endovascular repair of abdominal aortic aneurysms in kidney transplanted patients.MethodsA retrospective review of all patients who underwent endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA) performed at our institution from 2007 to 2014. We identified all patients who had previously undergone a kidney transplant. Data collected included: comorbidities, preoperative imaging modalities, indication for surgery, stent graft configurations, pre- and postoperative renal function, perioperative complications, and survival rates.ResultsA total of 267 EVARs were performed. Six (2 %) had a transplanted kidney. Mean age was 74 (range, 64–82) years; five were males. Mean time from transplantation to EVAR was 7.5 (range, 2–12) years. Five underwent preoperative planning with noncontrast modalities only. Devices used included bifurcated (n = 3), aortouniiliac (n = 2), and tube (n = 1) stent grafts. Technical success was achieved in all patients. None experienced deterioration in renal function. Median follow-up was 39 (range, 6–51) months. Four patients were alive at the time of the study. Two patients expired during the period of follow-up from unrelated causes.ConclusionsEVAR is an effective modality for the management of AAAs in the coexistence of a transplanted kidney. It can be performed with minimal morbidity and mortality without harming the transplanted kidney. Special consideration should be given to device configuration to minimize damage to the renal graft

  20. Endovascular Repair of Abdominal Aortic Aneurysms in the Presence of a Transplanted Kidney

    Energy Technology Data Exchange (ETDEWEB)

    Silverberg, Daniel, E-mail: silverberg-d@msn.com; Yalon, Tal; Halak, Moshe [The Chaim Sheba Medical Center, The Department of Vascular Surgery (Israel)

    2015-08-15

    PurposeTo present our experience performing endovascular repair of abdominal aortic aneurysms in kidney transplanted patients.MethodsA retrospective review of all patients who underwent endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA) performed at our institution from 2007 to 2014. We identified all patients who had previously undergone a kidney transplant. Data collected included: comorbidities, preoperative imaging modalities, indication for surgery, stent graft configurations, pre- and postoperative renal function, perioperative complications, and survival rates.ResultsA total of 267 EVARs were performed. Six (2 %) had a transplanted kidney. Mean age was 74 (range, 64–82) years; five were males. Mean time from transplantation to EVAR was 7.5 (range, 2–12) years. Five underwent preoperative planning with noncontrast modalities only. Devices used included bifurcated (n = 3), aortouniiliac (n = 2), and tube (n = 1) stent grafts. Technical success was achieved in all patients. None experienced deterioration in renal function. Median follow-up was 39 (range, 6–51) months. Four patients were alive at the time of the study. Two patients expired during the period of follow-up from unrelated causes.ConclusionsEVAR is an effective modality for the management of AAAs in the coexistence of a transplanted kidney. It can be performed with minimal morbidity and mortality without harming the transplanted kidney. Special consideration should be given to device configuration to minimize damage to the renal graft.

  1. Treatment of a Chronic Aneurysmal Aortic Dissection in a Patient with Marfan Syndrome Using a Staged Hybrid Procedure and a Fenestrated Endograft

    International Nuclear Information System (INIS)

    Walkden, R. Miles; Morgan, Rob A.; Loftus, Ian; Thompson, Matt

    2008-01-01

    Patients with aneurysmal dissections involving both the thoracic and the abdominal aorta are particularly challenging to treat with endovascular techniques because of the natural communications at the level of the visceral arteries. We present the case of a patient with Marfan syndrome with an aneurysmal aortic dissection involving the thoracic and abdominal aorta who was treated by a combination of endografts, surgical bypass, and a fenestrated tube graft.

  2. Early-Dynamic Positron Emission Tomography (PET)/Computed Tomography and PET Angiography for Endoleak Detection After Endovascular Aneurysm Repair.

    Science.gov (United States)

    Drescher, Robert; Gühne, Falk; Freesmeyer, Martin

    2017-06-01

    To propose a positron emission tomography (PET)/computed tomography (CT) protocol including early-dynamic and late-phase acquisitions to evaluate graft patency and aneurysm diameter, detect endoleaks, and rule out graft or vessel wall inflammation after endovascular aneurysm repair (EVAR) in one examination without intravenous contrast medium. Early-dynamic PET/CT of the endovascular prosthesis is performed for 180 seconds immediately after intravenous injection of F-18-fluorodeoxyglucose. Data are reconstructed in variable time frames (time periods after tracer injection) to visualize the arterial anatomy and are displayed as PET angiography or fused with CT images. Images are evaluated in view of vascular abnormalities, graft configuration, and tracer accumulation in the aneurysm sac. Whole-body PET/CT is performed 90 to 120 minutes after tracer injection. This protocol for early-dynamic PET/CT and PET angiography has the potential to evaluate vascular diseases, including the diagnosis of complications after endovascular procedures.

  3. Fenestration of the anterior cerebral artery

    International Nuclear Information System (INIS)

    Ito, J.; Washiyama, K.; Hong Kim, C.; Ibuchi, Y.

    1981-01-01

    Three cases of angiographically demonstrated fenestration of the anterior cerebral artery are reported. Fenestration occurred at the medial half of the horizontal segment of the anterior cerebral artery in all cases. Its embryology and clinical significance are briefly discussed, and the anatomical and radiological literature on fenestration of the anterior cerebral artery is reviewed. (orig.)

  4. Aortic Arch Aneurysms: Treatment with Extra anatomical Bypass and Endovascular Stent-Grafting

    International Nuclear Information System (INIS)

    Kato, Noriyuki; Shimono, Takatsugu; Hirano, Tadanori; Mizumoto, Toru; Ishida, Masaki; Fujii, Hideki; Yada, Isao; Takeda, Kan

    2002-01-01

    Endovascular repair of thoracic aortic aneurysms is emerging as an attractive alternative to surgical graft replacement. However,patients with aortic arch aneurysms are often excluded from the target of endovascular repair because of lack of suitable landing zones, especially at the proximal ones. In this paper we describe our method for treating patients with aortic arch aneurysms using a combination of extra anatomical bypass surgery and endovascular stent-grafting

  5. Meta-analysis of individual-patient data from EVAR-1, DREAM, OVER and ACE trials comparing outcomes of endovascular or open repair for abdominal aortic aneurysm over 5 years

    NARCIS (Netherlands)

    Powell, J. T.; Sweeting, M. J.; Ulug, P.; Blankensteijn, J. D.; Lederle, F. A.; Becquemin, J.-P.; Greenhalgh, R. M.; Beard, J. D.; Buxton, M. J.; Brown, L. C.; Harris, P. L.; Rose, J. D. G.; Russell, I. T.; Sculpher, M. J.; Thompson, S. G.; Lilford, R. J.; Bell, P. R. F.; Whitaker, S. C.; Poole-Wilson, The Late P. A.; Ruckley, C. V.; Campbell, W. B.; Dean, M. R. E.; Ruttley, M. S. T.; Coles, E. C.; Halliday, A.; Gibbs, S. J.; Epstein, D.; Hannon, R. J.; Johnston, L.; Bradbury, A. W.; Henderson, M. J.; Parvin, S. D.; Shepherd, D. F. C.; Mitchell, A. W.; Edwards, P. R.; Abbott, G. T.; Higman, D. J.; Vohra, A.; Ashley, S.; Robottom, C.; Wyatt, M. G.; Byrne, D.; Edwards, R.; Leiberman, D. P.; McCarter, D. H.; Taylor, P. R.; Reidy, J. F.; Wilkinson, A. R.; Ettles, D. F.; Clason, A. E.; Leen, G. L. S.; Wilson, N. V.; Downes, M.; Walker, S. R.; Lavelle, J. M.; Gough, M. J.; McPherson, S.; Scott, D. J. A.; Kessell, D. O.; Naylor, R.; Sayers, R.; Fishwick, N. G.; Gould, D. A.; Walker, M. G.; Chalmers, N. C.; Garnham, A.; Collins, M. A.; Gaines, P. A.; Ashour, M. Y.; Uberoi, R.; Braithwaite, B.; Davies, J. N.; Travis, S.; Hamilton, G.; Platts, A.; Shandall, A.; Sullivan, B. A.; Sobeh, M.; Matson, M.; Fox, A. D.; Orme, R.; Yusef, W.; Doyle, T.; Horrocks, M.; Hardman, J.; Blair, P. H. B.; Ellis, P. K.; Morris, G.; Odurny, A.; Vohra, R.; Duddy, M.; Thompson, M.; Loosemore, T. M. L.; Belli, A. M.; Morgan, R.; Adiseshiah, M.; Brookes, J. A. S.; McCollum, C. N.; Ashleigh, R.; Aukett, M.; Baker, S.; Barbe, E.; Batson, N.; Bell, J.; Blundell, J.; Boardley, D.; Boyes, S.; Brown, O.; Bryce, J.; Carmichael, M.; Chance, T.; Coleman, J.; Cosgrove, C.; Curran, G.; Dennison, T.; Devine, C.; Dewhirst, N.; Errington, B.; Farrell, H.; Fisher, C.; Fulford, P.; Gough, M.; Graham, C.; Hooper, R.; Horne, G.; Horrocks, L.; Hughes, B.; Hutchings, T.; Ireland, M.; Judge, C.; Kelly, L.; Kemp, J.; Kite, A.; Kivela, M.; Lapworth, M.; Lee, C.; Linekar, L.; Mahmood, A.; March, L.; Martin, J.; Matharu, N.; McGuigen, K.; Morris-Vincent, P.; Murray, S.; Murtagh, A.; Owen, G.; Ramoutar, V.; Rippin, C.; Rowley, J.; Sinclair, J.; Spencer, S.; Taylor, V.; Tomlinson, C.; Ward, S.; Wealleans, V.; West, J.; White, K.; Williams, J.; Wilson, L.; Grobbee, D. E.; Bak, A. A. A.; Buth, J.; Pattynama, P. M.; Verhoeven, E. L. G.; van Voorthuisen, A. E.; Balm, R.; Cuypers, P. W. M.; Prinssen, M.; van Sambeek, M. R. H. M.; Baas, A. F.; Hunink, M. G.; van Engelshoven, J. M.; Jacobs, M. J. H. M.; de Mol, B. A. J. M.; van Bockel, J. H.; Reekers, J.; Tielbeek, X.; Wisselink, W.; Boekema, N.; Heuveling, L. M.; Sikking, I.; de Bruin, J. L.; Tielbeek, A. V.; Pattynama, P.; Prins, T.; van der Ham, A. C.; van der Velden, J. J. I. M.; van Sterkenburg, S. M. M.; ten Haken, G. B.; Bruijninckx, C. M. A.; van Overhagen, H.; Tutein Nolthenius, R. P.; Hendriksz, T. R.; Teijink, J. A. W.; Odink, H. F.; de Smet, A. A. E. A.; Vroegindeweij, D.; van Loenhout, R. M. M.; Rutten, M. J.; Hamming, J. F.; Lampmann, L. E. H.; Bender, M. H. M.; Pasmans, H.; Vahl, A. C.; de Vries, C.; Mackaay, A. J. C.; van Dortmont, L. M. C.; van der Vliet, A. J.; Schultze Kool, L. J.; Boomsma, J. H. B.; van Dop, H. R.; de Mol van Otterloo, J. C. A.; de Rooij, T. P. W.; Smits, T. M.; Yilmaz, E. N.; van den Berg, F. G.; Visser, M. J. T.; van der Linden, E.; Schurink, G. W. H.; de Haan, M.; Smeets, H. J.; Stabel, P.; van Elst, F.; Poniewierski, J.; Vermassen, F. E. G.; Freischlag, J. A.; Kohler, T. R.; Latts, E.; Matsumura, J.; Padberg, F. T.; Kyriakides, T. C.; Swanson, K. M.; Guarino, P.; Peduzzi, P.; Antonelli, M.; Cushing, C.; Davis, E.; Durant, L.; Joyner, S.; Kossack, The Late A.; LeGwin, Mary; McBride, V.; O'Connor, T.; Poulton, J.; Stratton, The Late S.; Zellner, S.; Snodgrass, A. J.; Thornton, J.; Haakenson, C. M.; Stroupe, K. T.; Jonk, Y.; Hallett, J. W.; Hertzer, N.; Towne, J.; Katz, D. A.; Karrison, T.; Matts, J. P.; Marottoli, R.; Kasl, S.; Mehta, R.; Feldman, R.; Farrell, W.; Allore, H.; Perry, E.; Niederman, J.; Randall, F.; Zeman, M.; Beckwith, The Late D.; O'Leary, T. J.; Huang, G. D.; Bader, M.; Ketteler, E. R.; Kingsley, D. D.; Marek, J. M.; Massen, R. J.; Matteson, B. D.; Pitcher, J. D.; Langsfeld, M.; Corson, J. D.; Goff, J. M.; Kasirajan, K.; Paap, C.; Robertson, D. C.; Salam, A.; Veeraswamy, R.; Milner, R.; Guidot, J.; Lal, B. K.; Busuttil, S. J.; Lilly, M. P.; Braganza, M.; Ellis, K.; Patterson, M. A.; Jordan, W. D.; Whitley, D.; Taylor, S.; Passman, M.; Kerns, D.; Inman, C.; Poirier, J.; Ebaugh, J.; Raffetto, J.; Chew, D.; Lathi, S.; Owens, C.; Hickson, K.; Dosluoglu, H. H.; Eschberger, K.; Kibbe, M. R.; Baraniewski, H. M.; Endo, M.; Busman, A.; Meadows, W.; Evans, M.; Giglia, J. S.; El Sayed, H.; Reed, A. B.; Ruf, M.; Ross, S.; Jean-Claude, J. M.; Pinault, G.; Kang, P.; White, N.; Eiseman, M.; Jones, The Late R.; Timaran, C. H.; Modrall, J. G.; Welborn, M. B.; Lopez, J.; Nguyen, T.; Chacko, J. K. Y.; Granke, K.; Vouyouka, A. G.; Olgren, E.; Chand, P.; Allende, B.; Ranella, M.; Yales, C.; Whitehill, T. A.; Krupski, The Late W. C.; Nehler, M. R.; Johnson, S. P.; Jones, D. N.; Strecker, P.; Bhola, M. A.; Shortell, C. K.; Gray, J. L.; Lawson, J. H.; McCann, R.; Sebastian, M. W.; Kistler Tetterton, J.; Blackwell, C.; Prinzo, P. A.; Lee, N.; Cerveira, J. J.; Zickler, R. W.; Hauck, K. A.; Berceli, S. A.; Lee, W. A.; Ozaki, C. K.; Nelson, P. R.; Irwin, A. S.; Baum, R.; Aulivola, B.; Rodriguez, H.; Littooy, F. N.; Greisler, H.; O'Sullivan, M. T.; Kougias, P.; Lin, P. H.; Bush, R. L.; Guinn, G.; Bechara, C.; Cagiannos, C.; Pisimisis, G.; Barshes, N.; Pillack, S.; Guillory, B.; Cikrit, D.; Lalka, S. G.; Lemmon, G.; Nachreiner, R.; Rusomaroff, M.; O'Brien, E.; Cullen, J. J.; Hoballah, J.; Sharp, W. J.; McCandless, J. L.; Beach, V.; Minion, D.; Schwarcz, T. H.; Kimbrough, J.; Ashe, L.; Rockich, A.; Warner-Carpenter, J.; Moursi, M.; Eidt, J. F.; Brock, S.; Bianchi, C.; Bishop, V.; Gordon, I. L.; Fujitani, R.; Kubaska, S. M.; Behdad, M.; Azadegan, R.; Ma Agas, C.; Zalecki, K.; Hoch, J. R.; Carr, S. C.; Acher, C.; Schwarze, M.; Tefera, G.; Mell, M.; Dunlap, B.; Rieder, J.; Stuart, J. M.; Weiman, D. S.; Abul-Khoudoud, O.; Garrett, H. E.; Walsh, S. M.; Wilson, K. L.; Seabrook, G. R.; Cambria, R. A.; Brown, K. R.; Lewis, B. D.; Framberg, S.; Kallio, C.; Barke, R. A.; Santilli, S. M.; d'Audiffret, A. C.; Oberle, N.; Proebstle, C.; Johnson, L. L.; Jacobowitz, G. R.; Cayne, N.; Rockman, C.; Adelman, M.; Gagne, P.; Nalbandian, M.; Caropolo, L. J.; Pipinos, I. I.; Johanning, J.; Lynch, T.; DeSpiegelaere, H.; Purviance, G.; Zhou, W.; Dalman, R.; Lee, J. T.; Safadi, B.; Coogan, S. M.; Wren, S. M.; Bahmani, D. D.; Maples, D.; Thunen, S.; Golden, M. A.; Mitchell, M. E.; Fairman, R.; Reinhardt, S.; Wilson, M. A.; Tzeng, E.; Muluk, S.; Peterson, N. M.; Foster, M.; Edwards, J.; Moneta, G. L.; Landry, G.; Taylor, L.; Yeager, R.; Cannady, E.; Treiman, G.; Hatton-Ward, S.; Salabsky, The Late B.; Kansal, N.; Owens, E.; Estes, M.; Forbes, B. A.; Sobotta, C.; Rapp, J. H.; Reilly, L. M.; Perez, S. L.; Yan, K.; Sarkar, R.; Dwyer, S. S.; Perez, S.; Chong, K.; Hatsukami, T. S.; Glickerman, D. G.; Sobel, M.; Burdick, T. S.; Pedersen, K.; Cleary, P.; Back, M.; Bandyk, D.; Johnson, B.; Shames, M.; Reinhard, R. L.; Thomas, S. C.; Hunter, G. C.; Leon, L. R.; Westerband, A.; Guerra, R. J.; Riveros, M.; Mills, J. L.; Hughes, J. D.; Escalante, A. M.; Psalms, S. B.; Day, N. N.; Macsata, R.; Sidawy, A.; Weiswasser, J.; Arora, S.; Jasper, B. J.; Dardik, A.; Gahtan, V.; Muhs, B. E.; Sumpio, B. E.; Gusberg, R. J.; Spector, M.; Pollak, J.; Aruny, J.; Kelly, E. L.; Wong, J.; Vasilas, P.; Joncas, C.; Gelabert, H. A.; DeVirgillio, C.; Rigberg, D. A.; Cole, L.; Marzelle, J.; Sapoval, M.; Favre, J.-P.; Watelet, J.; Lermusiaux, P.; Lepage, E.; Hemery, F.; Dolbeau, G.; Hawajry, N.; Cunin, P.; Harris, P.; Stockx, L.; Chatellier, G.; Mialhe, C.; Fiessinger, J.-N.; Pagny, L.; Kobeiter, H.; Boissier, C.; Lacroix, P.; Ledru, F.; Pinot, J.-J.; Deux, J.-F.; Tzvetkov, B.; Duvaldestin, P.; Jourdain, C.; DAVID, V.; Enouf, D.; Ady, N.; Krimi, A.; Boudjema, N.; Jousset, Y.; Enon, B.; Blin, V.; Picquet, J.; L'Hoste, P.; Thouveny, F.; Borie, H.; Kowarski, S.; Pernes, J.-M.; Auguste, M.; Desgranges, P.; Allaire, E.; Meaulle, P.-Y.; Chaix, D.; Juliae, P.; Fabiani, J. N.; Chevalier, P.; Combes, M.; Seguin, A.; Belhomme, D.; Baque, J.; Pellerin, O.; Favre, J. P.; Barral, X.; Veyret, C.; Peillon, C.; Plissonier, D.; Thomas, P.; Clavier, E.; Martinez, R.; Bleuet, F.; C, Dupreix; Verhoye, J. P.; Langanay, T.; Heautot, J. F.; Koussa, M.; Haulon, S.; Halna, P.; Destrieux, L.; Lions, C.; Wiloteaux, S.; Beregi, J. P.; Bergeron, P.; Patra, P.; Costargent, A.; Chaillou, P.; D'Alicourt, A.; Goueffic, Y.; Cheysson, E.; Parrot, A.; Garance, P.; Demon, A.; Tyazi, A.; Pillet, J.-C.; Lescalie, F.; Tilly, G.; Steinmetz, E.; Favier, C.; Brenot, R.; Krause, D.; Cercueil, J. P.; Vahdat, O.; Sauer, M.; Soula, P.; Querian, A.; Garcia, O.; Levade, M.; Colombier, D.; Cardon, J.-M.; Joyeux, A.; Borrelly, P.; Dogas, G.; Magnan, P.-É; Branchereau, A.; Bartoli, J.-M.; Hassen-Khodja, R.; Batt, M.; Planchard, P.-F.; Bouillanne, P.-J.; Haudebourg, P.; Bayne, J.; Gouny, P.; Badra, A.; Braesco, J.; Nonent, M.; Lucas, A.; Cardon, A.; Kerdiles, Y.; Rolland, Y.; Kassab, M.; Brillu, C.; Goubault, F.; Tailboux, L.; Darrieux, H.; Briand, O.; Maillard, J.-C.; Varty, K.; Cousins, C.

    2017-01-01

    The erosion of the early mortality advantage of elective endovascular aneurysm repair (EVAR) compared with open repair of abdominal aortic aneurysm remains without a satisfactory explanation. An individual-patient data meta-analysis of four multicentre randomized trials of EVAR versus open repair

  6. Influence of diabetes mellitus on the endovascular treatment of abdominal aortic aneurysms.

    NARCIS (Netherlands)

    Leurs, L.J.; Laheij, R.J.F.; Buth, J.

    2005-01-01

    PURPOSE: To investigate the influence of diabetes mellitus on outcome after endovascular abdominal aortic aneurysm (AAA) repair. METHODS: Of 6017 patients enrolled in the EUROSTAR registry after undergoing endovascular AAA repair between May 1994 and December 2003, 731 (12%) had diabetes mellitus

  7. Endovascular Aneurysm Repair Using a Reverse Chimney Technique in a Patient With Marfan Syndrome and Contained Ruptured Chronic Type B Dissection

    International Nuclear Information System (INIS)

    Ketelsen, Dominik; Kalender, Guenay; Heuschmid, Martin; Syha, Roland; Mangold, Stefanie; Claussen, Claus D.; Brechtel, Klaus

    2011-01-01

    We report endovascular thoracic and abdominal aneurysm repair (EVAR) with reverse chimney technique in a patient with contained ruptured type B dissection. EVAR seems feasible as a bailout option in Marfan patients with acute life-threatening disease.

  8. Endovascular Management of Acute Bleeding Arterioenteric Fistulas

    International Nuclear Information System (INIS)

    Leonhardt, Henrik; Mellander, Stefan; Snygg, Johan; Loenn, Lars

    2008-01-01

    The objective of this study was to review the outcome of endovascular transcatheter repair of emergent arterioenteric fistulas. Cases of abdominal arterioenteric fistulas (defined as a fistula between a major artery and the small intestine or colon, thus not the esophagus or stomach), diagnosed over the 3-year period between December 2002 and December 2005 at our institution, were retrospectively reviewed. Five patients with severe enteric bleeding underwent angiography and endovascular repair. Four presented primary arterioenteric fistulas, and one presented a secondary aortoenteric fistula. All had massive persistent bleeding with hypotension despite volume substitution and transfusion by the time of endovascular management. Outcome after treatment of these patients was investigated for major procedure-related complications, recurrence, reintervention, morbidity, and mortality. Mean follow-up time was 3 months (range, 1-6 months). All massive bleeding was controlled by occlusive balloon catheters. Four fistulas were successfully sealed with stent-grafts, resulting in a technical success rate of 80%. One patient was circulatory stabilized by endovascular management but needed immediate further open surgery. There were no procedure-related major complications. Mean hospital stay after the initial endovascular intervention was 19 days. Rebleeding occurred in four patients (80%) after a free interval of 2 weeks or longer. During the follow-up period three patients needed reintervention. The in-hospital mortality was 20% and the 30-day mortality was 40%. The midterm outcome was poor, due to comorbidities or rebleeding, with a mortality of 80% within 6 months. In conclusion, endovascular repair is an efficient and safe method to stabilize patients with life-threatening bleeding arterioenteric fistulas in the emergent episode. However, in this group of patients with severe comorbidities, the risk of rebleeding is high and further intervention must be considered

  9. Association of left subclavian artery coverage without revascularization and spinal cord ischemia in patients undergoing thoracic endovascular aortic repair: A Vascular Quality Initiative® analysis.

    Science.gov (United States)

    Teixeira, Pedro Gr; Woo, Karen; Beck, Adam W; Scali, Salvatore T; Weaver, Fred A

    2017-12-01

    Objectives Investigate the impact of left subclavian artery coverage without revascularization on spinal cord ischemia development in patients undergoing thoracic endovascular aortic repair. Methods The Vascular Quality Initiative thoracic endovascular aortic repair module (April 2011-July 2014) was analyzed. Patients undergoing left subclavian artery coverage were divided into two groups according to revascularization status. The association between left subclavian artery revascularization with the primary outcome of spinal cord ischemia and the secondary outcome of stroke was assessed with multivariable analysis adjusting for between-group baseline differences. Results The left subclavian artery was covered in 508 (24.6%) of the 2063 thoracic endovascular aortic repairs performed. Among patients with left subclavian artery coverage, 58.9% underwent revascularization. Spinal cord ischemia incidence was 12.1% in the group without revascularization compared to 8.5% in the group undergoing left subclavian artery revascularization (odds ratio (95%CI): 1.48(0.82-2.68), P = 0.189). Multivariable analysis adjustment identified an independent association between left subclavian artery coverage without revascularization and the incidence of spinal cord ischemia (adjusted odds ratio (95%CI): 2.29(1.03-5.14), P = 0.043). Although the incidence of stroke was also higher for the group with a covered and nonrevascularized left subclavian artery (12.1% versus 8.5%), this difference was not statistically significant after multivariable analysis (adjusted odds ratio (95%CI): 1.55(0.74-3.26), P = 0.244). Conclusion For patients undergoing left subclavian artery coverage during thoracic endovascular aortic repair, the addition of a revascularization procedure was associated with a significantly lower incidence of spinal cord ischemia.

  10. [Midterm results of thoracic aortic dissection endovascular repair in conjunctions with the location of Adamkiewicz artery].

    Science.gov (United States)

    Jia, Ying-bin; Li, Jian; Su, Yong-hui; Ma, Jie-fei; Guan, Xiao-dong; Zhang, Bai-meng

    2012-10-23

    To evaluate the effects of using longer xenografts in conjunctions with the location of Adamkiewicz artery (AKA) on midterm outcomes of endovascular treatment for thoracic aortic dissection. From March 2005 to September 2011, 217 patients with type B dissection were recruited. There were 143 males and 74 females with a mean age of 65 ± 11 years. Among them, 43 patients were from Fifth Affiliated Hospital of Sun Yat-Sen University while another 174 patients from Affiliated Zhongshan Hospital of Fudan University. They were divided into 2 groups according to whether AKA was identified or not pre-operatively. Endovascular repairs were performed for all patients. Distal landing levels of xenografts were recorded. The thrombosis of false lumen and the complications of spinal cord injury and endoleak were analyzed. AKA was detected in 121 (55.8%) patients (group A) but not in 96 (44.2%) patients (group B). According to the levels of AKA, the patients of group A obtained the stabilization of affected thoracic aorta over a longer distance. And the ratio of patients with distal landing levels at T8-T10 was significantly higher than in group B (59.5% vs 12.5%, χ² = 49.85, P < 0.01). Also, during the follow-up period of 7.3 months, the ratio of patients with total thrombosis of false lumen in group A was significantly higher than that in group B (32.1% vs 19.1%, χ² = 4.34, P < 0.05). During the endovascular repair of thoracic aortic dissection, selecting a longer device may provide a better structural stability of affected aorta and promote false lumen thrombosis.

  11. Extra-Thoracic Supra-aortic Bypass Surgery Is Safe in Thoracic Endovascular Aortic Repair and Arterial Occlusive Disease Treatment.

    Science.gov (United States)

    Gombert, Alexander; van Issum, Lea; Barbati, Mohammad E; Grommes, Jochen; Keszei, Andras; Kotelis, Drosos; Jalaie, Houman; Greiner, Andreas; Jacobs, Michael J; Kalder, Johannes

    2018-04-20

    The safety and feasibility of supra-aortic debranching as part of endovascular aortic surgery or as a treatment option for arterial occlusive disease (AOD) remains controversial. The aim of this study was to assess the clinical outcome of this surgery. This single centre, retrospective study included 107 patients (mean age 69.2 years, 38.4% women) who underwent supra-aortic bypass surgery (carotid-subclavian bypass, carotid-carotid bypass, and carotid-carotid-subclavian bypass) because of thoracic or thoraco-abdominal endovascular aortic repair (57%; 61/107) or as AOD treatment (42.9%; 46/107) between January 2006 and January 2015. Mortality, morbidity with a focus on neurological complications, and patency rate were assessed. Twenty-six of 107 (14.2%) of the debranching patients were treated under emergency conditions because of acute type B dissection or symptomatic aneurysm. Follow up, conducted by imaging interpretation and telephone interviews, continued till March 2017 (mean 42.1, 0-125, months). The in hospital mortality rate was 10.2% (11/107), all of these cases from the debranching group and related to emergency procedures (p supra-aortic bypass surgery involves low complication rates and high mid-term bypass patency rates. It is a safe and feasible treatment option in the form of debranching in combination with endovascular aortic aneurysm repair and in AOD. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  12. Aortopulmonary Fistula Presenting without an Endoleak after Thoracic Endovascular Aortic Repair

    Directory of Open Access Journals (Sweden)

    Giacomo Sica

    2017-08-01

    Full Text Available Herein, we report the case of a 60-year-old man, a smoker with a history of arterial hypertension and diabetes mellitus. After computed tomography (CT for an episode of hemoptysis, the patient underwent elective thoracic endovascular aortic repair (TEVAR because of a degenerative aneurysm of the descending thoracic aorta. The area of perianeurysmal pulmonary atelectasis reported on the CT scan was not considered. Three months later, he developed an aortopulmonary fistula without endoleaks. Although TEVAR is a relatively safe procedure, no detail should be overlooked in the preoperative evaluation in order to avoid life-threatening complications. Further, the effectiveness and modality of prolonged antibiotic prophylaxis and/or preoperative respiratory physiotherapy should be assessed in such cases.

  13. Validation of the Simbionix PROcedure Rehearsal Studio sizing module : A comparison of software for endovascular aneurysm repair sizing and planning

    NARCIS (Netherlands)

    Velu, Juliëtte F.; Groot Jebbink, Erik; de Vries, Jean-Paul P.M.; Slump, Cornelis H.; Geelkerken, Robert H.

    2017-01-01

    An important determinant of successful endovascular aortic aneurysm repair is proper sizing of the dimensions of the aortic-iliac vessels. The goal of the present study was to determine the concurrent validity, a method for comparison of test scores, for EVAR sizing and planning of the recently

  14. Acute Testicular Ischemia following Endovascular Abdominal Aortic Aneurysm Repair Identified in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Nathan Finnerty

    2014-01-01

    Full Text Available Endovascular aneurysm repair (EVAR is perhaps the most widely utilized surgical procedure for patients with large abdominal aortic aneurysms. This procedure is minimally invasive and reduces inpatient hospitalization requirements. The case involves a 72-year-old male who presented to the emergency department with right testicular ischemia two days following EVAR. Given the minimal inpatient hospitalization associated with this procedure, emergency physicians are likely to encounter associated complications. Ischemic and thromboembolic events following EVAR are extremely rare but require prompt vascular surgery intervention to minimize morbidity and mortality.

  15. CT appearance of complications related to thoracic endovascular aortic repair (TEVAR): a pictorial essay

    International Nuclear Information System (INIS)

    Pua, U.; Tay, K.H.; Tan, B.S.; Htoo, M.M.; Sebastian, M.; Sin, K.; Chua, Y.L.

    2009-01-01

    Thoracic endovascular aortic repair (TEVAR) is a recognized treatment for various diseases involving the thoracic aorta. Patients treated with TEVAR require lifelong surveillance for potential complications, with CT being highly utilized in most centres. Endoleak is the most common complication and can be detected using CT. However, other complications such as stent strut perforations and end organ ischemia can also be detected on CT. The purpose of this pictorial essay is to illustrate the CT appearance of post-TEVAR complications encountered in our institution and to highlight their significance. (orig.)

  16. CT appearance of complications related to thoracic endovascular aortic repair (TEVAR): a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Pua, U. [Singapore General Hospital, Department of Diagnostic Radiology, Singapore (Singapore); Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore); Tay, K.H.; Tan, B.S.; Htoo, M.M. [Singapore General Hospital, Department of Diagnostic Radiology, Singapore (Singapore); Sebastian, M. [Singapore General Hospital, Department of General Surgery, Singapore (Singapore); Sin, K.; Chua, Y.L. [National Heart Centre, Department of Cardiothoracic and Vascular Surgery, Singapore (Singapore)

    2009-05-15

    Thoracic endovascular aortic repair (TEVAR) is a recognized treatment for various diseases involving the thoracic aorta. Patients treated with TEVAR require lifelong surveillance for potential complications, with CT being highly utilized in most centres. Endoleak is the most common complication and can be detected using CT. However, other complications such as stent strut perforations and end organ ischemia can also be detected on CT. The purpose of this pictorial essay is to illustrate the CT appearance of post-TEVAR complications encountered in our institution and to highlight their significance. (orig.)

  17. Thoracic Endovascular Aortic Repair (TEVAR) in Proximal (Type A) Aortic Dissection: Ready for a Broader Application?

    OpenAIRE

    Nienaber, Christoph A.; Sakalihasan, Natzi; Clough, Rachel E.; Aboukoura, Mohamed; Mancuso, Enrico; Yeh, James S.M.; Defraigne, Jean-Olivier; Cheshire, Nick; Rosendahl, Ulrich Peter; Quarto, Cesare; Pepper, John

    2016-01-01

    ObjectiveThoracic endovascular aortic repair (TEVAR) has demonstrated encouraging results and is gaining increasing acceptance as a treatment option for aortic aneurysms and dissections. Yet, its role in managing proximal aortic pathologies is unknown - this is important because in proximal (Stanford type A) aortic dissections, 10-30% are not accepted for surgery, and 30-50% are technically amenable for TEVAR. We describe our case series of type A aortic dissections treated using TEVAR.Method...

  18. Penetrating Atherosclerotic Ulcer of the Abdominal Aorta Involving the Celiac Trunk Origin and Superior Mesenteric Artery Occlusion: Endovascular Treatment

    International Nuclear Information System (INIS)

    Ferro, Carlo; Rossi, Umberto G.; Petrocelli, Francesco; Seitun, Sara; Robaldo, Alessandro; Mazzei, Raffaele

    2011-01-01

    We describe a case of endovascular treatment in a 64-year-old woman affected by a penetrating atherosclerotic ulcer (PAU) of the abdominal aorta with a 26-mm pseudoaneurysm involving the celiac trunk (CT) origin and with superior mesenteric artery (SMA) occlusion in the first 30 mm. The patient underwent stenting to treat the SMA occlusion and subsequent deployment of a custom-designed fenestrated endovascular stent-graft to treat the PAU involving the CT origin. Follow-up at 6 months after device placement demonstrated no complications, and there was complete thrombosis of the PAU and patency of the two branch vessels.

  19. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    International Nuclear Information System (INIS)

    Steingruber, I.E.; Neuhauser, B.; Seiler, R.; Greiner, A.; Chemelli, A.; Kopf, H.; Walch, C.; Waldenberger, P.; Jaschke, W.; Czermak, B.

    2006-01-01

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions

  20. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Steingruber, I.E. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)]. E-mail: iris.steingruber@uibk.ac.at; Neuhauser, B. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Seiler, R. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Greiner, A. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Chemelli, A. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Kopf, H. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Walch, C. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Waldenberger, P. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Jaschke, W. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Czermak, B. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)

    2006-09-15

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions.

  1. Brain aneurysm repair

    Science.gov (United States)

    ... aneurysm repair; Dissecting aneurysm repair; Endovascular aneurysm repair - brain; Subarachnoid hemorrhage - aneurysm ... Your scalp, skull, and the coverings of the brain are opened. A metal clip is placed at ...

  2. Retrograde Ascending Dissection After Thoracic Endovascular Aortic Repair Combined With the Chimney Technique and Successful Open Repair Using the Frozen Elephant Trunk Technique.

    Science.gov (United States)

    Hirano, Koji; Tokui, Toshiya; Nakamura, Bun; Inoue, Ryosai; Inagaki, Masahiro; Maze, Yasumi; Kato, Noriyuki

    2018-01-01

    The chimney technique can be combined with thoracic endovascular aortic repair (TEVAR) to both obtain an appropriate landing zone and maintain blood flow of the arch vessels. However, surgical repair becomes more complicated if retrograde type A aortic dissection occurs after TEVAR with the chimney technique. We herein report a case involving a 73-year-old woman who developed a retrograde ascending dissection 3 months after TEVAR for acute type B aortic dissection. To ensure an adequate proximal sealing distance, the proximal edge of the stent graft was located at the zone 2 level and an additional bare stent was placed at the left subclavian artery (the chimney technique) at the time of TEVAR. Enhanced computed tomography revealed an aortic dissection involving the ascending aorta and aortic arch. Surgical aortic repair using the frozen elephant trunk technique was urgently performed. The patient survived without stroke, paraplegia, renal failure, or other major complications. Retrograde ascending dissection can occur after TEVAR combined with the chimney technique. The frozen elephant trunk technique is useful for surgical repair in such complicated cases.

  3. Suprarenal fixation resulting in intestinal malperfusion after endovascular aortic aneurysm repair.

    Science.gov (United States)

    Siani, Andrea; Accrocca, Federico; De Vivo, Gennaro; Marcucci, Giustino

    2016-05-01

    Superior mesenteric artery (SMA) and coeliac axis (CA) occlusion after endovascular abdominal aneurysm aortic repair (EVAR-AAA), using endograft with suprarenal fixation, are uncommon. However, we are reporting a case of visceral malperfusion, which occurred 7 days after successful EVAR with suprarenal fixation for symptomatic AAA. Endograft metal stent barbs caused severe stenosis of SMA and CA. A successful recovery of SMA was carried out by means of a balloon-expandable stent released through bare metal stent barbs. We believe that an unfavourable anatomy of a proximal aortic neck and visceral aorta may have caused a wrong stent strut deployment with the coverage of CA and SMA. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. A regenerative approach towards mucosal fenestration closure

    Science.gov (United States)

    Gandi, Padma; Anumala, Naveen; Reddy, Amarender; Viswa Chandra, Rampalli

    2013-01-01

    Mucosal fenestration is an opening or an interstice through the oral mucosa. A lesion which occurs with greater frequency than generally realised, its occurrence is attributed to a myriad of causes. Mucogingival procedures including connective tissue grafts, free gingival grafts and lateral pedicle grafts are generally considered to be the treatment of choice in the closure of a mucosal fenestration. More often, these procedures are performed in conjunction with other procedures such as periradicular surgery and with bone grafts. However, the concomitant use of gingival grafts and bone grafts in mucosal fenestrations secondary to infections in sites exhibiting severe bone loss is highly debatable. In this article, we report two cases of mucosal fenestrations secondary to trauma and their management by regenerative periodontal surgery with the placement of guided tissue regeneration membrane and bone graft. The final outcome was a complete closure of the fenestration in both the cases. PMID:23749826

  5. [Failed transcatheter creation of fenestration in a Fontan patient with original fenestration closed by AngelWings septal occluder: a case report].

    Science.gov (United States)

    Ohno, Atsuko; Hirotaka, Ishido; Kobayashi, Toshiki; Asano, Haruhiko; Kyo, Shunei; Senzaki, Hideaki

    2007-10-01

    The fenestrated Fontan procedure has helped to reduce the mortality and morbidity of pediatric patients who underwent the Fontan operation. We treated a patient (7-year-old, female) who had developed heart failure 1 year after fenestration closure using an AngelWings device, although the patient met the proposed criteria for test occlusion. Hemodynamic evaluation using the ventricular pressure-area relationship revealed that the patient had both systolic and diastolic dysfunction, which were difficult to recognize by conventional hemodynamic indices. We then tried to percutaneously create a fenestration using a Brockenbrough needle, but this procedure failed. The AngelWings device, which may have been covered by pseudointima (composed of fibroelastic tissue), was hard enough to break the Brockenbrough needle. Re-creating a fenestration after device closure in patients after the fenestrated Fontan operation appears to be difficult, so more accurate methods to predict Fontan physiology after fenestration closure are needed.

  6. Endovascular treatment of type II endoleak following thoracic endovascular aortic repair for thoracic aortic aneurysm: Case report of squeeze technique to reach the aneurysmal sac

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hyun Jung; Kim, Chang Won; Lee, Tae Hong; Song, Seung Hwan; Lee, Chung Won; Chung, Sung Woon [Pusan National University Hospital, School of Medicine, Pusan National University, Busan (Korea, Republic of)

    2014-12-15

    Type II endoleaks are common after thoracic endovascular aortic repair (TEVAR). Various strategies are introduced to manage type II endoleaks, such as the use of coils, plugs, or liquid embolic agents (histoacryl, thrombin, onyx, etc.) through a transarterial approach or a direct puncture of the aneurysmal sac. We herein report a case of a type II endoleak caused by reverse blood flow through intercostal artery after TEVAR which was successfully treated with n-butyl cyanoacrylate (histoacryl)-lipiodol mixture by a squeeze technique to reach the aneurismal sac using a microcatheter.

  7. Endodontic and periodontal management of a severely affected maxillary lateral incisor having combined mucosal fenestration and palatogingival groove

    Directory of Open Access Journals (Sweden)

    Sarang Sharma

    2015-01-01

    Full Text Available Mucosal fenestrations, wherein the tooth root apices are clinically discernible in the oral cavity subsequent to loss of overlying alveolar bone and mucosa, are rare pathologic entities. Palato gingival grooves- anatomic aberrations are also infrequent occurrences that notoriously predispose to periodontal pathologies of varying extent. Both conditions independently are known to popularly affect maxillary lateral incisors. Coexistent fenestration defect and palato gingival groove in the same tooth is extremely rare and undoubtedly is a perfect combination to precipitate severe endodontic-periodontal consequences. In this report, a 34-year-old patient presented to the dental department with complaint of esthetics in relation to exposed root of right maxillary lateral incisor. On closer inspection, a palato gingival groove in addition to fenestration defect was evident on the root surface along with a periodontal pocket of >5 mm. An interdisciplinary treatment was instituted which included endodontic treatment followed by root end resection, osseous bone graft placement and guided tissue regeneration procedures for repair of mucosal fenestration defect. Debridement of the palatal pocket, with saucerization of the groove and restoration with glass ionomer cement were simultaneously employed to correct the palatal defect.

  8. Endovascular repair of mycotic aneurysm of the descending thoracic aorta: diagnostic and therapeutic dilemmas-two case reports with 1-year follow-up.

    Science.gov (United States)

    Marjanovic, Ivan; Sarac, Momir; Tomic, Aleksandar; Bezmarevic, Mihailo

    2013-10-01

    A mycotic aneurysm of the thoracic aorta is a rare diagnosis with high mortality. We present two cases of endovascular reconstruction of mycotic descending thoracic aorta. Specific or nonspecific bacterial or other infectious agent in serial samples of blood, urine, cerebrospinal fluid, and pleural puncture was not detected in the first case, but we found in sputum sample Mycobacterium tuberculosis in the second patient. We empirically began by administering broad-spectrum intravenous antibiotics in the first case, with preoperative antibiotic prophylaxis and antituberculotic drugs therapy in the second case, and continued with the same medication for 4 months after endovascular repair. Control computed tomographic scans 6 months after reconstruction showed no endoleak in both patients. Repair of mycotic descending thoracic aortic aneurysms by endoluminal stent graft is reasonable alternative to open surgical intervention. A broad-spectrum antibiotic therapy has a high significance in the treatment of patients with mycotic aneurysm. Georg Thieme Verlag KG Stuttgart · New York.

  9. Endovascular abdominal aortic aneurysm repair complicated by spondylodiscitis and iliaco-enteral fistula.

    Science.gov (United States)

    de Koning, Heleen D; van Sterkenburg, Steven M M; Pierie, Maurice E N; Reijnen, Michel M P J

    2008-06-01

    Infections of abdominal aortic endografts are rare. There are no reports on the association with spondylodiscitis. We report a case of a 74-year-old man who underwent endovascular aneurysm repair (EVAR) and subsequently femorofemoral bypass placement due to occlusion of the right limb of the endograft. Six months later, he presented with rectal bleeding, weight loss, back pain, and low abdominal pain. Computed tomography revealed extensive abscess formation with air in and around the endograft and psoas muscles, in continuity with destructive spondylodiscitis L3-4. There was a small bowel loop in close proximity to the occluded right leg of the endograft, which was filled with air bubbles. An axillofemoral bypass was created followed by a laparotomy. Intra-operatively, an iliaco-enteral fistula was found. The small bowel defect was sutured, the endograft completely removed, and the infrarenal aorta and both common iliac arteries were closed. Necrotic fragments of the former L3-4 disk were removed. The postoperative course was uneventful. Seven months postoperatively, the patient had recovered well. Iliaco-enteric fistula and spondylodiscitis are rare complications of aortic aneurysm repair. This is the first report of spondylodiscitis after EVAR.

  10. Endovascular stenting of a chronic ruptured type B thoracic aortic dissection, a second chance: a case report.

    Science.gov (United States)

    Arshad, Ali; Khan, Sumaira L; Whitaker, Simon C; Macsweeney, Shane T

    2008-02-07

    We aim to highlight the need for awareness of late complications of endovascular thoracic aortic stenting and the need for close follow-up of patients treated by this method. We report the first case in the English literature of an endovascular repair of a previously stented, ruptured chronic Stanford type B thoracic aortic dissection re-presenting with a type III endoleak of the original repair. Endovascular thoracic stenting is now a widely accepted technique for the treatment of thoracic aortic dissection and its complications. Long term follow up is necessary to ensure that late complications are identified and treated appropriately. In this case of type III endoleak, although technically challenging, endovascular repair was feasible and effective.

  11. The imaging assessment and specific endograft design for the endovascular repair of ascending aortic dissection

    Directory of Open Access Journals (Sweden)

    Zhang Y

    2016-07-01

    (10.4%, 22 (45.9%, 13 (27.1%, six (12.5%, and two (4.2% patients, respectively. Conclusion: In this selected number of Chinese patients, the suitability of endovascular repair has been demonstrated based on the CT imaging. Shorter, larger, and bare spring-free conical endografts were preferred in the ascending aortic pathology. Keywords: type A dissection, endovascular, endograft, design

  12. The repair of a type Ia endoleak following thoracic endovascular aortic repair using a stented elephant trunk procedure.

    Science.gov (United States)

    Qi, Rui-Dong; Zhu, Jun-Ming; Liu, Yong-Min; Chen, Lei; Li, Cheng-Nan; Xing, Xiao-Yan; Sun, Li-Zhong

    2018-04-01

    Type Ia endoleaks are not uncommon complications that occur after thoracic endovascular aortic repair (TEVAR). Because aortic arch vessels prevent extension of the landing zone, it is very difficult to manipulate a type Ia endoleak using an extension cuff or stent-graft, especially when the aortic arch is involved. Here, we retrospectively review our experience of surgical treatment of type Ia endoleak after TEVAR using a stented elephant trunk procedure. From July 2010 to August 2016, we treated 17 patients diagnosed with a type Ia endoleak following TEVAR using stented elephant trunk procedure. The mean age of our patients was 52 ± 8 years. The mean interval between TEVAR and the open surgical repair was 38 ± 43 months. All cases of type Ia endoleak (100%) were repaired successfully. There were no in-hospital deaths. One case required reintubation and continuous renal replacement therapy due to renal failure; this patient recovered smoothly before discharge. One other patient suffered a stroke and renal failure and did not fully recover following discharge, or follow-up. During follow-up, there were 3 deaths. Acceptable results were obtained using a stented elephant trunk procedure in patients with a type Ia endoleak after TEVAR. This technique allowed us to repair the proximal aortic arch lesions, surgically correct the type Ia endoleak, and promote false lumen thrombosis in the distal aorta. Implantation of a stented elephant trunk, with or without a concomitant aortic arch procedure, is an alternative approach for this type of lesion. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  13. Fontan fenestration closure and event-free survival.

    Science.gov (United States)

    Imielski, Bartlomiej R; Woods, Ronald K; Mussatto, Kathleen A; Cao, Yumei; Simpson, Pippa M; Tweddell, James S

    2013-01-01

    The purpose of the present study was to evaluate the association of open and closed Fontan fenestration status with event-free survival. All patients who underwent a fenestrated Fontan procedure at our institution from January 1994 through June 2007 were reviewed. Patient information was obtained from the medical records. The patients were assigned to 1 of 2 study groups, open or closed, according to their most recent fenestration status. Clinically relevant morbid events were tabulated, and Kaplan-Meier event analysis was used to create event-free probability curves with log-rank comparisons. A total of 161 patients were classified as open and 51 as closed. The median interval to an event was 1.1 years (interquartile range, 0.1-3.3 years) after the Fontan procedure. The median interval to closure was 1.2 years (interquartile range, 0.7-3.3 years). The median interval to an event was 1.5 years (interquartile range, 0.1-4.6 years) in the closed group and 1.1 years (interquartile range, 0.1-3.3 years) in the open group. Event-free probability analysis revealed no significant difference between the 2 groups (P = .15). The median follow-up arterial oxygen saturation was greater in the closed group (96.0%; interquartile range, 94.0%-97.0%) than in the open group (91.0%; interquartile range, 86.0%-95.0%; P < .0001). Fenestration closure was associated with greater arterial oxygen saturation but not greater event-free survival. The interval to an event was slightly less than the interval to fenestration closure, suggesting potential merit in the evaluation of earlier fenestration closure. Adoption of specific fenestration management guidelines might help improve the overall outcomes and enhance the quality of future studies. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  14. Vascular Rupture Caused by a Molding Balloon during Endovascular Aneurysm Repair: Case Report

    International Nuclear Information System (INIS)

    Lee, Hee Young; Do, Young Soo; Park, Hong Suk; Park, Kwang Bo; Kim, Young Wook; Kim, Dong Ik

    2011-01-01

    Endovascular aneurysm repair (EVAR) has been accepted as an alternative to traditional open surgery in selected patients. Despite the minimally invasiveness of this treatment, several complications may occur during or after EVAR. Complications include endoleak, aortic dissection, distal embolism, or iatrogenic injury to the access artery. However, there are few reports on the vascular rupture caused by a molding balloon during EVAR. We report two cases of infrarenal abdominal aortic aneurysms complicated by procedure-related aortic or iliac artery rupture by the molding balloon during EVAR. In our cases, we observed suddenly abrupt increase of the diameter of the endograft during balloon inflation, because we inflated the balloon rapidly. In conclusion, careful attention must be paid during inflation of the molding balloon to prevent vascular rupture.

  15. Endovascular treatment of complex traumatic lesions of the infrapopliteal segment Tratamento endovascular de lesões traumáticas complexas do segmento infrapoplíteo

    Directory of Open Access Journals (Sweden)

    Roberta C. A. Campos

    2009-06-01

    Full Text Available The occurrence of vascular trauma due to a range of causes has increased considerably. In this setting, endovascular repair has arisen as a new and less invasive approach. We report the case of three patients with lesions of below-knee vessels that were treated by endovascular procedures.A ocorrência de trauma vascular decorrente de diversas causas aumentou consideravelmente. Nesse contexto, o tratamento endovascular surge como um método novo e menos invasivo. Relatamos o caso de três pacientes com lesões abaixo do joelho que foram tratadas por procedimentos endovasculares.

  16. Early experience with the multilayer aneurysm repair stent in the endovascular treatment of trans/infragenicular popliteal artery aneurysms: a mixed bag.

    Science.gov (United States)

    Thakar, Tejal; Chaudhuri, Arindam

    2013-06-01

    To present a preliminary experience using a multilayer flow-modulating stent for trans/infragenicular popliteal endovascular aneurysm repair. Five men (mean age 76 years, range 62-86) with 6 popliteal artery aneurysms (PAAs) measuring 22 to 39 mm in diameter (mean 30) underwent endovascular repair using the Cardiatis Multilayer Aneurysm Repair System (MARS) between June and August 2011. Radiological assessments post procedure using duplex ultrasonography and biplanar knee radiographs (additional contrast studies as necessary) sought evidence of aneurysm exclusion, graft patency, and preservation of branches and runoff vessels. Technical success was achieved in each case. There was one symptomatic stent occlusion requiring thrombectomy at 4 days, with reocclusion, and one leak via the stent struts into the sac with no branch outflow identified. Two further symptomatic stent occlusions were identified within a 6-week follow-up period, totaling 3 occlusions among the 6 devices deployed. No firm conclusion can be reached on the efficacy of the MARS in PAAs due to the inherent limitations of this small series, although a 50% thrombosis rate is a poor outcome. The risk of early thrombosis in flow-modulating stents deployed in the popliteal artery exists, as it does with earlier generation stent-grafts. Larger prospective trials and the influence of more aggressive antithrombotic/anticoagulant therapy should be considered to enable accurate evaluation of this device in popliteal artery aneurysms.

  17. Fenestration System Performance Research, Testing, and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jim Benney

    2009-11-30

    The US DOE was and is instrumental to NFRC's beginning and its continued success. The 2005 to 2009 funding enables NFRC to continue expanding and create new, improved ratings procedures. Research funded by the US DOE enables increased fenestration energy rating accuracy. International harmonization efforts supported by the US DOE allow the US to be the global leader in fenestration energy ratings. Many other governments are working with the NFRC to share its experience and knowledge toward development of their own national fenestration rating process similar to the NFRC's. The broad and diverse membership composition of NFRC allows anyone with a fenestration interest to come forward with an idea or improvement to the entire fenestration community for consideration. The NFRC looks forward to the next several years of growth while remaining the nation's resource for fair, accurate, and credible fenestration product energy ratings. NFRC continues to improve its rating system by considering new research, methodologies, and expanding to include new fenestration products. Currently, NFRC is working towards attachment energy ratings. Attachments are blinds, shades, awnings, and overhangs. Attachments may enable a building to achieve significant energy savings. An NFRC rating will enable fair competition, a basis for code references, and a new ENERGY STAR product category. NFRC also is developing rating methods to consider non specular glazing such as fritted glass. Commercial applications frequently use fritted glazing, but no rating method exists. NFRC is testing new software that may enable this new rating and contribute further to energy conservation. Around the world, many nations are seeking new energy conservation methods and NFRC is poised to harmonize its rating system assisting these nations to better manage and conserve energy in buildings by using NFRC rated and labeled fenestration products. As this report has shown, much more work needs to be

  18. Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

    International Nuclear Information System (INIS)

    Okada, Takuya; Yamaguchi, Masato; Kitagawa, Atsushi; Kawasaki, Ryota; Nomura, Yoshikatsu; Okita, Yutaka; Sugimura, Kazuro; Sugimoto, Koji

    2012-01-01

    Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non–contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47–2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

  19. Endovascular repair of abdominal aortic aneurysm.

    Science.gov (United States)

    Paravastu, Sharath Chandra Vikram; Jayarajasingam, Rubaraj; Cottam, Rachel; Palfreyman, Simon J; Michaels, Jonathan A; Thomas, Steven M

    2014-01-23

    An abnormal dilatation of the abdominal aorta is referred to as an abdominal aortic aneurysm (AAA). Due to the risk of rupture, surgical repair is offered electively to individuals with aneurysms greater than 5.5 cm in size. Traditionally, conventional open surgical repair (OSR) was considered the first choice approach. However, over the past two decades endovascular aneurysm repair (EVAR) has gained popularity as a treatment option. This article intends to review the role of EVAR in the management of elective AAA. To assess the effectiveness of EVAR versus conventional OSR in individuals with AAA considered fit for surgery, and EVAR versus best medical care in those considered unfit for surgery. This was determined by the effect on short, intermediate and long-term mortality, endograft related complications, re-intervention rates and major complications. The Cochrane Peripheral Vascular Diseases Group Trials Search Co-ordinator (TSC) searched the Specialised Register (January 2013) and the Cochrane Central Register of Controlled Trials (CENTRAL) (2012, Issue 12). The TSC also searched trial databases for details of ongoing or unpublished studies. Prospective randomised controlled trials (RCTs) comparing EVAR with OSR in individuals with AAA considered fit for surgery. and comparing EVAR with best medical care in individuals considered unfit for surgery. We excluded studies with inadequate data or using an inadequate randomisation technique. Three reviewers independently evaluated trials for appropriateness for inclusion and extracted data using pro forma designed by the Cochrane PVD Group. We assessed the quality of trials using The Cochrane Collaboration's 'Risk of bias' tool. We entered collected data in to Review Manager (version 5.2.3) for analysis. Where direct comparisons could be made, we determined odds ratios (OR). We tested studies for heterogeneity and, when present, we used a random-effects model; otherwise we used a fixed-effect model. We tabulated

  20. Late graft explants in endovascular aneurysm repair.

    Science.gov (United States)

    Turney, Eric J; Steenberge, Sean P; Lyden, Sean P; Eagleton, Matthew J; Srivastava, Sunita D; Sarac, Timur P; Kelso, Rebecca L; Clair, Daniel G

    2014-04-01

    With more than a decade of use of endovascular aneurysm repair (EVAR), we expect to see a rise in the number of failing endografts. We review a single-center experience with EVAR explants to identify patterns of presentation and understand operative outcomes that may alter clinical management. A retrospective analysis of EVARs requiring late explants, >1 month after implant, was performed. Patient demographics, type of graft, duration of implant, reason for removal, operative technique, length of stay, complications, and in-hospital and late mortality were reviewed. During 1999 to 2012, 100 patients (91% men) required EVAR explant, of which 61 were placed at another institution. The average age was 75 years (range, 50-93 years). The median length of time since implantation was 41 months (range, 1-144 months). Explanted grafts included 25 AneuRx (Medtronic, Minneapolis, Minn), 25 Excluder (W. L. Gore & Associates, Flagstaff, Ariz), 17 Zenith (Cook Medical, Bloomington, Ind), 15 Talent (Medtronic), 10 Ancure (Guidant, Indianapolis, Ind), 4 Powerlink (Endologix, Irvine, Calif), 1 Endurant (Medtronic), 1 Quantum LP (Cordis, Miami Lakes, Fla), 1 Aorta Uni Iliac Rupture Graft (Cook Medical, Bloomington, Ind), and 1 homemade tube graft. Overall 30-day mortality was 17%, with an elective case mortality of 9.9%, nonelective case mortality of 37%, and 56% mortality for ruptures. Endoleak was the most common indication for explant, with one or more endoleaks present in 82% (type I, 40%; II, 30%; III, 22%; endotension, 6%; multiple, 16%). Other reasons for explant included infection (13%), acute thrombosis (4%), and claudication (1%). In the first 12 months, 23 patients required explants, with type I endoleak (48%) and infection (35%) the most frequent indication. Conversely, 22 patients required explants after 5 years, with type I (36%) and type III (32%) endoleak responsible for most indications. The rate of EVAR late explants has increased during the past decade at our

  1. Mid-term cost-effectiveness analysis of open and endovascular repair for ruptured abdominal aortic aneurysm.

    Science.gov (United States)

    Rollins, K E; Shak, J; Ambler, G K; Tang, T Y; Hayes, P D; Boyle, J R

    2014-02-01

    Emergency endovascular repair (EVAR) for ruptured abdominal aortic aneurysm (rAAA) may have lower operative mortality rates than open surgical repair. Concerns remain that the early survival benefit after EVAR for rAAA may be offset by late reinterventions. The aim of this study was to compare reintervention rates and cost-effectiveness of EVAR and open repair for rAAA. A retrospective analysis was undertaken of patients with rAAA undergoing EVAR or open repair over 6 years. A health economic model developed for the cost-effectiveness of elective EVAR was used in the emergency setting. Sixty-two patients (mean age 77·9 years) underwent EVAR and 85 (mean age 75·9 years) had open repair of rAAA. Median follow-up was 42 and 39 months respectively. There was no significant difference in 30-day mortality rates after EVAR and open repair (18 and 26 per cent respectively; P = 0·243). Reintervention rates were also similar (32 and 31 per cent; P = 0·701). The mean cost per patient was €26,725 for EVAR and €30,297 for open repair, and the cost per life-year gained was €7906 and €9933 respectively (P = 0·561). Open repair had greater initial costs: longer procedural times (217 versus 178·5 min; P < 0·001) and intensive care stay (5·0 versus 1·0 days; P = 0·015). Conversely, EVAR had greater reintervention (€156,939 versus €35,335; P = 0·001) and surveillance (P < 0·001) costs. There was no significant difference in reintervention rates after EVAR or open repair for rAAA. EVAR was as cost-effective at mid-term follow-up. The increased procedural costs of open repair are not outweighed by greater surveillance and reintervention costs after EVAR. © 2014 BJS Society Ltd. Published by John Wiley & Sons Ltd.

  2. Retrograde type A dissection following hybrid supra-aortic endovascular surgery in high-risk patients unfit for conventional open repair.

    Science.gov (United States)

    Yip, Hon C; Chan, Yiu C; Qing, Kai X; Cheng, Stephen W

    2018-04-01

    Hybrid procedures with combined open extra-anatomical supra-aortic bypasses and endovascular surgery are less invasive for patients with complex aortic arch pathology. The aim of this paper is to report patients who developed retrograde type A aortic dissection following initially successful hybrid endovascular treatment. Retrospective review of prospectively collected computerized departmental database. All patients with supra-aortic hybrid endovascular surgery and post-procedure retrograde type A dissection were identified. Patient demographics, comorbid conditions, perioperative parameters, procedural details and post-operative complications were collected. From May 2005 to July 2014, 163 patients underwent thoracic aortic endovascular procedures at our institution. From the 46 patients who had supra-aortic hybrid endovascular repair, six patients (6/46, 13% of all supra-aortic hybrid cases, 3 males) developed retrograde type A aortic dissection. All were elective cases, with 3 chronic dissecting aneurysms and 3 atherosclerotic aneurysms. All had one-stage hybrid procedures: 2 patients had carotid-carotid bypass grafts, one had carotid-carotid-left subclavian bypass graft, and 3 had bypass grafts from ascending aorta to innominate artery and left carotid artery. Five patients had Cook Zenith thoracic stent-grafts (Cook Medical, Bloomington, IN, USA), and one had Medtronic Valiant stent-grafts (Medtronic Vascular Inc, Santa Rosa, CA, USA). The retrograde type A dissection occurred with sudden symptoms at day 5, 6, 10, 20, 105 and 128, respectively. There were 3 immediate fatalities and 2 patients treated conservatively deemed unfit for reintervention (one died of pneumonia at 9 months, and one remained alive at 7 months post-complication). One patient underwent successful emergency open surgery and survived. Supra-aortic hybrid procedures in treating aortic arch pathology may be at risk of developing retrograde type A dissection. This post-operative complication

  3. Percutaneous endovascular aneurysm repair in morbidly obese patients.

    Science.gov (United States)

    Chin, Jason A; Skrip, Laura; Sumpio, Bauer E; Cardella, Jonathan A; Indes, Jeffrey E; Sarac, Timur P; Dardik, Alan; Ochoa Chaar, Cassius I

    2017-03-01

    Endovascular aneurysm repair (EVAR) with percutaneous femoral access (PEVAR) has several potential advantages. Morbidly obese (MO) patients present unique anatomical challenges and have not been specifically studied. This study examines the trends in the use of PEVAR and its surgical outcomes compared with open femoral cutdown (CEVAR) in MO patients. The American College of Surgeons National Surgical Quality Improvement Program files for the years 2005 to 2013 were reviewed. The study included all MO patients (body mass index [BMI] ≥40 kg/m 2 ) undergoing EVAR. Patients were categorized as having CEVAR if they had any one of 11 selected Current Procedural Terminology (American Medical Association, Chicago, Ill) codes describing an open femoral procedure. The PEVAR group included any remaining patients who had only codes for EVAR and endovascular procedures. Linear correlation was used to evaluate temporal trends in the use of PEVAR among MO patients. Baseline comorbidities and surgical outcomes were compared between the PEVAR and CEVAR groups using χ 2 tests or t-tests. There were 833 MO patients (470 CEVAR and 363 PEVAR) constituting 3.0% of all patients undergoing EVAR. The use of PEVAR in MO patients significantly increased from 27.3% of total EVARs in the years 2005 to 2006 to 48.6% in 2013 (P = .039). The two groups had similar baseline characteristics, including age, BMI, comorbidities, and emergency procedures, except for history of severe chronic obstructive pulmonary disease (29.6% CEVAR vs 22.6% PEVAR; P = .024). PEVAR patients had shorter duration of anesthesia (244 vs 260 minutes; P = .048) and shorter total operation time (158 vs 174 minutes; P = .002). PEVAR patients had significantly decreased wound complications (5.5% vs 9.4%; P = .039). There was a trend towards PEVAR patients being more likely to be discharged home than to a facility (93.6% vs 87.8%; P = .060). There was no difference in any other complication or mortality. A subgroup

  4. Seventeen Years’ Experience of Late Open Surgical Conversion after Failed Endovascular Abdominal Aortic Aneurysm Repair with 13 Variant Devices

    International Nuclear Information System (INIS)

    Wu, Ziheng; Xu, Liang; Qu, Lefeng; Raithel, Dieter

    2015-01-01

    PurposeTo investigate the causes and results of late open surgical conversion (LOSC) after failed abdominal aortic aneurysm repair (EVAR) and to summarize our 17 years’ experience with 13 various endografts.MethodsRetrospective data from August 1994 to January 2011 were analyzed at our center. The various devices’ implant time, the types of devices, the rates and causes of LOSC, and the procedures and results of LOSC were analyzed and evaluated.ResultsA total of 1729 endovascular aneurysm repairs were performed in our single center (Nuremberg South Hospital) with 13 various devices within 17 years. The median follow-up period was 51 months (range 9–119 months). Among them, 77 patients with infrarenal abdominal aortic aneurysms received LOSC. The LOSC rate was 4.5 % (77 of 1729). The LOSC rates were significantly different before and after January 2002 (p < 0.001). The reasons of LOSC were mainly large type I endoleaks (n = 51) that were hard to repair by endovascular techniques. For the LOSC procedure, 71 cases were elective and 6 were emergent. The perioperative mortality was 5.2 % (4 of 77): 1 was elective (due to septic shock) and 3 were urgent (due to hemorrhagic shock).ConclusionLarge type I endoleaks were the main reasons for LOSC. The improvement of devices and operators’ experience may decrease the LOSC rate. Urgent LOSC resulted in a high mortality rate, while selective LOSC was relatively safe with significantly lower mortality rate. Early intervention, full preparation, and timely LOSC are important for patients who require LOSC

  5. Seventeen Years’ Experience of Late Open Surgical Conversion after Failed Endovascular Abdominal Aortic Aneurysm Repair with 13 Variant Devices

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Ziheng, E-mail: wuziheng303@hotmail.com [Zhejiang University, Department of Vascular Surgery, The First Affiliated Hospital, School of Medicine (China); Xu, Liang, E-mail: maxalive@163.com [Zhejiang University, Department of Neurosurgery, The Second Affiliated Hospital, School of Medicine (China); Qu, Lefeng, E-mail: qulefeng@gmail.com [The Second Military Medical University, Department of Vascular and Endovascular Surgery, Changzheng Hospital (China); Raithel, Dieter, E-mail: dieter.raithel@rzmail.uni-erlangen.de [Nuremberg Southern Hospital, Department of Vascular and Endovascular Surgery (Germany)

    2015-02-15

    PurposeTo investigate the causes and results of late open surgical conversion (LOSC) after failed abdominal aortic aneurysm repair (EVAR) and to summarize our 17 years’ experience with 13 various endografts.MethodsRetrospective data from August 1994 to January 2011 were analyzed at our center. The various devices’ implant time, the types of devices, the rates and causes of LOSC, and the procedures and results of LOSC were analyzed and evaluated.ResultsA total of 1729 endovascular aneurysm repairs were performed in our single center (Nuremberg South Hospital) with 13 various devices within 17 years. The median follow-up period was 51 months (range 9–119 months). Among them, 77 patients with infrarenal abdominal aortic aneurysms received LOSC. The LOSC rate was 4.5 % (77 of 1729). The LOSC rates were significantly different before and after January 2002 (p < 0.001). The reasons of LOSC were mainly large type I endoleaks (n = 51) that were hard to repair by endovascular techniques. For the LOSC procedure, 71 cases were elective and 6 were emergent. The perioperative mortality was 5.2 % (4 of 77): 1 was elective (due to septic shock) and 3 were urgent (due to hemorrhagic shock).ConclusionLarge type I endoleaks were the main reasons for LOSC. The improvement of devices and operators’ experience may decrease the LOSC rate. Urgent LOSC resulted in a high mortality rate, while selective LOSC was relatively safe with significantly lower mortality rate. Early intervention, full preparation, and timely LOSC are important for patients who require LOSC.

  6. Endovascular Treatment of Infrarenal Abdominal Aortic Aneurysm with Short and Angulated Neck in High-Risk Patient

    Directory of Open Access Journals (Sweden)

    Stylianos Koutsias

    2013-01-01

    Full Text Available Endovascular treatment of abdominal aortic aneurysms (AAA is an established alternative to open repair. However lifelong surveillance is still required to monitor endograft function and signal the need for secondary interventions (Hobo and Buth 2006. Aortic morphology, especially related to the proximal neck, often complicates the procedure or increases the risk for late device-related complications (Hobo et al. 2007 and Chisci et al. 2009. The definition of a short and angulated neck is based on length (60° (Hobo et al. 2007 and Chisci et al. 2009. A challenging neck also offers difficulties during open repairs (OR, necessitating extensive dissection with juxta- or suprarenal aortic cross-clamping. Patients with extensive aneurysmal disease typically have more comorbidities and may not tolerate extensive surgical trauma (Sarac et al. 2002. It is, therefore, unclear whether aneurysms with a challenging proximal neck should be offered EVAR or OR (Cox et al. 2006, Choke et al. 2006, Robbins et al. 2005, Sternbergh III et al. 2002, Dillavou et al. 2003, and Greenberg et al. 2003. In our case the insertion of a thoracic endograft followed by the placement of a bifurcated aortic endograft for the treatment of a very short and severely angulated neck proved to be feasible offering acceptable duration of aneurysm exclusion. This adds up to our armamentarium in the treatment of high-risk patients, and it should be considered in emergency cases when the fenestrated and branched endografts are not available.

  7. Expression in Whole Blood Samples of miRNA-191 and miRNA-455-3p in Patients with AAA and Their Relationship to Clinical Outcomes after Endovascular Repair.

    Science.gov (United States)

    Tenorio, Emanuel Junio Ramos; Braga, Andre Felipe Farias; Tirapelli, Daniela Pretti Da Cunha; Ribeiro, Mauricio Serra; Piccinato, Carlos Eli; Joviliano, Edwaldo Edner

    2018-03-05

    The purpose of this study was to quantify and evaluate the expression response of miRNA-191 and miRNA-455-3p endovascular repair of abdominal aortic aneurysm (AAA) based in whole blood samples. This report describes a prospective study of a single center of 30 patients with AAA who underwent endovascular repair. Blood samples were collected preoperatively and 6 months postoperatively. The differential expression of the miRNAs was performed by the real-time polymerase chain reaction method, after extraction of the RNA from the blood samples at the 2 moments. In addition, bioinformatic tools were used to determine pathophysiological pathways related to AAA. The miR-191 and miR-455-3p were overexpressed preoperatively. After 6 months postoperatively, miR-191 (median 0.98, IQR 0.5-2.1, P AAA showed no significant differences in the expression of miR-191 and miR-455-3p. Exclusion of the aneurysmal sac after endovascular treatment induces a decrease in the expression of the studied miRNAs in whole blood samples, which suggests a possible use of them as biomarkers of therapeutic success. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Endovascular Treatment of Ruptured Abdominal Aortic Aneurysm with Aortocaval Fistula

    International Nuclear Information System (INIS)

    Guzzardi, Giuseppe; Fossaceca, Rita; Divenuto, Ignazio; Musiani, Antonello; Brustia, Piero; Carriero, Alessandro

    2010-01-01

    Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA). We report the endovascular repair of an AAA rupture into the inferior vena cava. A 78-year-old woman was admitted to our hospital for acute hypotension. She presented with a pulsatile abdominal mass and became rapidly anuric. Abdominal computed tomography (CT) showed an AAA rupture into the inferior vena cava. The features of the AAA made it suitable for endovascular repair. To prevent pulmonary embolism caused by the presence of sac thrombosis near the vena cava lumen, a temporary vena cava filter was deployed before the procedure. A bifurcated stent-graft was placed with the patient under local anaesthesia, and the AAA was successfully treated. A transient type II endoleak was detected on CT 3 days after endograft placement. At routine follow-up 6 and 12 months after the procedure, the patient was in good clinical condition, and the type II endoleak had sealed completely. Endovascular treatment offers an attractive therapeutic alternative to open repair in case of ACF; however, only small numbers of patients have been treated, and long-term follow-up interval is lacking.

  9. Endovascular management of an acquired aortobronchial fistula following aortic bypass for coarctation.

    LENUS (Irish Health Repository)

    O'Sullivan, Katie E

    2013-09-20

    Aortobronchial fistula (ABF) in the setting of aortic coarctation repair is very rare but uniformly fatal if untreated. Endovascular stenting of the descending aorta is now the first-choice approach for ABF presenting with haemoptysis and offers a less-invasive technique with improved outcomes, compared with open repair. We report a case of late ABF occurring following bypass for aortic coarctation. Management focused on two key manoeuvres: use of a covered endovascular stent to occlude the aortic bypass thus controlling the fistula and dilatation and stenting of native coarctation.

  10. Improving Results of Elective Abdominal Aortic Aneurysm Repair at a Low-Volume Hospital by Risk-Adjusted Selection of Treatment in the Endovascular Era

    International Nuclear Information System (INIS)

    Wibmer, Andreas; Meyer, Bernhard; Albrecht, Thomas; Buhr, Heinz-Johannes; Kruschewski, Martin

    2009-01-01

    Several studies have observed both higher mortality rates and lower utilization of endovascular aneurysm repair (EVAR) at low-volume centers. This article presents the results of elective abdominal aortic aneurysm (AAA) repair at a low-volume center in the endovascular era and investigates whether postprocedural mortality can be improved by extension of EVAR application also in this setting. This is an 11.6-year retrospective cohort study of 132 patients undergoing elective surgical or endovascular AAA repair at a tertiary care academic hospital between 1997 and July 2008, i.e., a median volume of 12 cases per year. The study was divided into two periods of time according to the respective indications and contraindications for EVAR, which substantially changed in 2005. During period 1, only aneurysms with necks ≥20 mm long and not involving the iliac arteries were treated endoluminally. Beginning in 2005, indication for EVAR was expanded to aortoiliac aneurysms with a minimum neck length of 15 mm. Preoperative risk was assessed by the SVS/AAVS comorbidity score. During the first period (1997-2004) 18.4% (16/87) of all patients received EVAR. By extending anatomical confines and indications for EVAR in 2005, the utilization rate of EVAR increased to 40.0% (18/45) during the second period (2005-July 2008; p = 0.007). Prevalence of preoperative risk factors did not change during the two observation periods. In contrast to period 1, high-risk patients were preferentially treated endoluminally during the second period, resulting in a significantly higher median SVS/AAVS score in the EVAR group (p < 0.001). A significant decrease in median length of stay at the intensive/intermediate care unit (5 vs. 2 days; p = 0.006) and length of in-hospital stay (20 vs. 12.5 days; p < 0.001) was observed during period 2. Overall perioperative mortality was reduced from 6.9% during the first period to 2.2% during the second period (p = 0.256). EVAR mortality was 0%, mortality after

  11. Coverage of Gingival Fenestration Using Modified Pouch and Tunnel Technique: A Novel Approach

    Directory of Open Access Journals (Sweden)

    Sunil Pendor

    2013-01-01

    Full Text Available Gingival fenestration defects are a rare phenomenon. Gingival fenestration means the exposure of the tooth due to loss of the overlying bone and gingiva. Though treatment of mucosal fenestration occurring in association with chronic periapical inflammation has been reported previously, the occurrence and treatment of gingival fenestration have not been documented in great detail. This report describes the occurrence of a gingival fenestration that developed secondarily to a gutka chewing habit. Treatment of the fenestration along with coverage of an adjacent recession defect in a single-step procedure using a pouch and tunnel technique is described.

  12. The Relationship between fenestrations, sieve plates and rafts in liver sinusoidal endothelial cells.

    Directory of Open Access Journals (Sweden)

    Dmitri Svistounov

    Full Text Available Fenestrations are transcellular pores in endothelial cells that facilitate transfer of substrates between blood and the extravascular compartment. In order to understand the regulation and formation of fenestrations, the relationship between membrane rafts and fenestrations was investigated in liver sinusoidal endothelial cells where fenestrations are grouped into sieve plates. Three dimensional structured illumination microscopy, scanning electron microscopy, internal reflectance fluorescence microscopy and two-photon fluorescence microscopy were used to study liver sinusoidal endothelial cells isolated from mice. There was an inverse distribution between sieve plates and membrane rafts visualized by structured illumination microscopy and the fluorescent raft stain, Bodipy FL C5 ganglioside GM1. 7-ketocholesterol and/or cytochalasin D increased both fenestrations and lipid-disordered membrane, while Triton X-100 decreased both fenestrations and lipid-disordered membrane. The effects of cytochalasin D on fenestrations were abrogated by co-administration of Triton X-100, suggesting that actin disruption increases fenestrations by its effects on membrane rafts. Vascular endothelial growth factor (VEGF depleted lipid-ordered membrane and increased fenestrations. The results are consistent with a sieve-raft interaction, where fenestrations form in non-raft lipid-disordered regions of endothelial cells once the membrane-stabilizing effects of actin cytoskeleton and membrane rafts are diminished.

  13. Acute optic nerve sheath fenestration with the free-electron laser

    Science.gov (United States)

    Shen, Jin-Hui; Casagrande, Vivien A.; Joos, Karen M.; Shetlar, Debra J.; Robinson, Richard D.; Head, William S.; Mavity-Hudson, Julia A.; Nunnally, Amy H.

    1999-06-01

    Purpose: To determine if the free electron laser (FEL) energy can be delivered to a small space to perform optic nerve sheath fenestration with minimal acute nerve damage. Methods: A 530 mm hollow waveguide probe was designed. Optic nerve sheath fenestration (1.0 mm diameter) was performed in 8 rabbits using either the FEL (4 eyes, 6.45mm, 10 Hz, 2 mJ) or a knife (4 eyes). Within 2 hours following surgery, the animals were perfused with aldehyde fixative. The integrity of the optic nerve and glial response at the site of fenestration were evaluated on tissue selections with H&E, and antibodies to S100β or GFAP. Results: Surgery using the FEL probe was found to be technically superior to the knife. The glial reaction was limited to a zone adjacent to the fenestration and was similar in both the FEL and knife incisions. Conclusions: The FEL appears capable of efficiently performing an optic nerve sheath fenestration in a small space with minimal acute damage. Both the FEL and knife incisions result in a rapid glial response at the site of fenestration even when optic nerve integrity is not compromised.

  14. Imaging and management of complications of open surgical repair of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Nayeemuddin, M.; Pherwani, A.D.; Asquith, J.R.

    2012-01-01

    Open repair is still considered the reference standard for long-term repair of abdominal aortic aneurysms (AAA). In contrast to endovascular aneurysm repair (EVAR), patients with open surgical repair of AAA are not routinely followed up with imaging. Although complications following EVAR are widely recognized and routinely identified on follow-up imaging, complications also do occur following open surgical repair. With frequent use of multi-slice computed tomography (CT) angiography (CTA) in vascular patients, there is now improved recognition of the potential complications following open surgical repair. Many of these complications are increasingly being managed using endovascular techniques. The aim of this review is to illustrate a variety of potential complications that may occur following open surgical repair and to demonstrate their management using both surgical and endovascular techniques.

  15. The β-d-Endoglucuronidase Heparanase Is a Danger Molecule That Drives Systemic Inflammation and Correlates with Clinical Course after Open and Endovascular Thoracoabdominal Aortic Aneurysm Repair: Lessons Learnt from Mice and Men

    Directory of Open Access Journals (Sweden)

    Lukas Martin

    2017-06-01

    Full Text Available Thoracoabdominal aortic aneurysm (TAAA is a highly lethal disorder requiring open or endovascular TAAA repair, both of which are rare, but extensive and complex surgical procedures associated with a significant systemic inflammatory response and high post-operative morbidity and mortality. Heparanase is a β-d-endoglucuronidase that remodels the endothelial glycocalyx by degrading heparan sulfate in many diseases/conditions associated with systemic inflammation including sepsis, trauma, and major surgery. We hypothesized that (a perioperative serum levels of heparanase and heparan sulfate are associated with the clinical course after open or endovascular TAAA repair and (b induce a systemic inflammatory response and renal injury/dysfunction in mice. Using a reverse-translational approach, we assessed (a the serum levels of heparanase, heparan sulfate, and the heparan sulfate proteoglycan syndecan-1 preoperatively as well as 6 and 72 h after intensive care unit (ICU admission in patients undergoing open or endovascular TAAA repair and (b laboratory and clinical parameters and 90-day survival, and (c the systemic inflammatory response and renal injury/dysfunction induced by heparanase and heparan sulfate in mice. When compared to preoperative values, the serum levels of heparanase, heparan sulfate, and syndecan-1 significantly transiently increased within 6 h of ICU admission and returned to normal within 72 h after ICU admission. The kinetics of any observed changes in heparanase, heparan sulfate, or syndecan-1 levels, however, did not differ between open and endovascular TAAA-repair. Postoperative heparanase levels positively correlated with noradrenalin dose at 12 h after ICU admission and showed a high predictive value of vasopressor requirements within the first 24 h. Postoperative heparan sulfate showed a strong positive correlation with interleukin-6 levels day 0, 1, and 2 post-ICU admission and a strong negative correlation with

  16. Endovascular Repair of Traumatic Rupture of the Thoracic Aorta: Single-Center Experience

    International Nuclear Information System (INIS)

    Saratzis, Nikolaos A.; Saratzis, Athanasios N.; Melas, Nikolaos; Ginis, Georgios; Lioupis, Athanasios; Lykopoulos, Dimitrios; Lazaridis, John; Dimitrios, Kiskinis

    2007-01-01

    Purpose. Traumatic rupture of the thoracic aorta secondary to blunt chest trauma is a life-threatening emergency and a common cause of death, usually following violent collisions. The objective of this retrospective report was to evaluate the efficacy of endovascular treatment of thoracic aortic disruptions with a single commercially available stent-graft. Methods. Nine men (mean age 29.5 years) were admitted to our institution between January 2003 and January 2006 due to blunt aortic trauma following violent motor vehicle collisions. Plain chest radiography, spiral computed tomography, aortography, and transesophageal echocardiography were used for diagnostic purposes in all cases. All patients were diagnosed with contained extramural thoracic aortic hematomas, secondary to aortic disruption. One patient was also diagnosed with a traumatic thoracic aortic dissection, secondary to blunt trauma. All subjects were poor surgical candidates, due to major injuries such as multiple bone fractures, abdominal hematomas, and pulmonary contusions. All repairs were performed using the EndoFit (LeMaitre Vascular) stent-graft. Results. Complete exclusion of the traumatic aortic disruption and pseudoaneurysm was achieved and verified at intraoperative arteriography and on CT scans, within 10 days of the repair in all patients. In 1 case the deployment of a second cuff was necessary due to a secondary endoleak. In 2 cases the left subclavian artery was occluded to achieve adequate graft fixation. No procedure-related deaths have occurred and no cardiac or peripheral vascular complications were observed within the 12 months (range 8-16 months) follow-up. Conclusions. This is the first time the EndoFit graft has been utilized in the treatment of thoracic aortic disruptions secondary to chest trauma. The repair of such pathologies is technically feasible and early follow-up results are promising

  17. Quantitative assessment of an aortic and pulmonary valve function according to valve fenestration

    International Nuclear Information System (INIS)

    Mirkhani, S.H.; Golestani, M.G.; Hosini, M.; Kazemian, A.

    1999-01-01

    There are some reasons for malfunction of aortic and pulmonary valve like fibrosis, calcification, and atheroma. Although, in some papers fenestration were known as a pathologic sign, but it is not generally accepted, while this matter is important in choosing suitable Homograft Heart Valve. In this paper fenestrations and its size, numbers and situation effect was studied. We collected 98 hearts, the donors died because of accident, we excluded valves with atheroma, calcification, fibrosis and unequal cusps, 91 aortic and 93 pulmonary valves were given further consideration. We classified valves according to situation, number and size of fenestration. Each valve was tested with 104 cm of non-nal saline column pressure which is equal to 76 mm Hg. Valve efficacy was detected by fluid flow assay. With study of 184 valves, 95 had no fenestration, 64 had less than 2 fenestration and 25 had more than 2 fenestration. Valve efficacy in condition of less than 2 fenestration was more than others (p <0.01). Malfunction effects of fenestration increased in larger valve and it will be decreased if their situation would be marginal (free margin of cusp). In the comparison of aortic and pulmonary valve we saw that malfunction effect of fenestration in pulmonary valve was more than aortic valve. Our experience in Immam Khomeini Homograft Valve Bank has shown that a great deal of valves is fenestrated. It seems that fenestration must be considered as a quality criterion in homograft valve preparation, especially in pulmonary and large aortic valves; but complementary studies is necessary

  18. Lighting characteristics of complex fenestration systems

    Energy Technology Data Exchange (ETDEWEB)

    Laouadi, A. [National Research Council of Canada, Ottawa, ON (Canada). Inst. for Research in Construction; Parekh, A. [Natural Resources Canada, Ottawa, ON (Canada). CANMET Energy Technology Centre, Sustainable Buildings and Community Group

    2006-07-01

    Innovations in window technologies have been motivated by the need for energy conservation in buildings. Shading devices and windows with complex glazings such as smart glazings, translucent and transparent insulation, and patterned glass are among the newly developed products. Although complex fenestration systems (CFS) have superior energy performance, a potential glare problem can have a significant effect on the indoor environment as experienced by occupants. A good view and glare-free environment are important for the commercialization of fenestration products. This study addressed the development of new lighting quality indices for the outdoor view, indoor view and window luminance. It was noted that the outdoor view gives a feeling of connection to the outside, an indoor view affects the feelings of privacy, while window luminance indicates the potential risk of discomfort glare. The study applied the new lighting quality indices on a typical complex fenestration system consisting of a double clear window combined with different types of an interior perforated shading screen with opaque and translucent materials. According to simulation results, the light-coloured screen has a significant impact on the outdoor view and window's luminance, and depends largely on the sky conditions. Under clear sky conditions, the luminance of a window with a translucent screen can increase by up to 80 per cent compared to overcast sky conditions. This study aspires to have these indices be part of a fenestration product ratings for indoor environment quality. 19 refs., 1 tab., 3 figs.

  19. High Performance Commercial Fenestration Framing Systems

    Energy Technology Data Exchange (ETDEWEB)

    Mike Manteghi; Sneh Kumar; Joshua Early; Bhaskar Adusumalli

    2010-01-31

    A major objective of the U.S. Department of Energy is to have a zero energy commercial building by the year 2025. Windows have a major influence on the energy performance of the building envelope as they control over 55% of building energy load, and represent one important area where technologies can be developed to save energy. Aluminum framing systems are used in over 80% of commercial fenestration products (i.e. windows, curtain walls, store fronts, etc.). Aluminum framing systems are often required in commercial buildings because of their inherent good structural properties and long service life, which is required from commercial and architectural frames. At the same time, they are lightweight and durable, requiring very little maintenance, and offer design flexibility. An additional benefit of aluminum framing systems is their relatively low cost and easy manufacturability. Aluminum, being an easily recyclable material, also offers sustainable features. However, from energy efficiency point of view, aluminum frames have lower thermal performance due to the very high thermal conductivity of aluminum. Fenestration systems constructed of aluminum alloys therefore have lower performance in terms of being effective barrier to energy transfer (heat loss or gain). Despite the lower energy performance, aluminum is the choice material for commercial framing systems and dominates the commercial/architectural fenestration market because of the reasons mentioned above. In addition, there is no other cost effective and energy efficient replacement material available to take place of aluminum in the commercial/architectural market. Hence it is imperative to improve the performance of aluminum framing system to improve the energy performance of commercial fenestration system and in turn reduce the energy consumption of commercial building and achieve zero energy building by 2025. The objective of this project was to develop high performance, energy efficient commercial

  20. Emergency endovascular management of peripheral artery aneurysms and pseudoaneurysms – a review

    Directory of Open Access Journals (Sweden)

    Gillard Jonathan H

    2008-07-01

    Full Text Available Abstract Endovascular stenting has been successfully employed in the management of aortic aneurysms; however, its use in managing peripheral arterial conditions remains questionable. We review the utility of endovascular technique in the management of peripheral arterial conditions like aneurysms, pseudoaneurysms and arterio-venous fistulas in the emergency setting. Though long term data about graft patency rates is not yet available, the endovascular approach appears to be a useful minimally invasive technique in situations where open repair is either difficult or not feasible.

  1. Endovascular treatment of the subclavian artery aneurysm in high-risk patient - a single-center experience

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2016-01-01

    Full Text Available We present our first experience with endovascular treatment of 6 subclavian artery aneurysms (SAA occurring in five male and one female patient. All patients, in our studies, according to ASA classification were high risk for open repair of SAA. The etiology of the all aneurysms was atherosclerosis degeneration of the artery. Two aneurysms were of intrathoracic location, then the other were extrathoracic. Symptoms related to subclavian artery aneurysms were present in two patients, compression and chest pain in one, and hemorrhage shock in second, while the remaining patients were asymptomatic. We preferred the Viabhan endoprosthesis for endovascular repair in 5 cases. In one patient with ruptured of subclavian artery aneurysm who was high-risk for open repair we made combined endovascular procedure. First at all, we covered the origin of left subclavian artery with thoracic stent graft and after that we put two coils in proximal part of subclavian artery. There was no operative mortality, and the early patency rate was 100%. The follow-up period was from 3 months to 3 years. During this period, one patient died of heart failure and one patient required endovascular reoperation due to endoleak type I. Endovascular treatment is recommended for all patients with subclavian artery aneurysm whenever this is possible due to anatomical reasons especially in high-risk patient with intrathoracic localization of aneurysm, to prevent potential complications.

  2. Anatomic study of juxta renal aneurysms: impact on fenestrated stent-grafts.

    Science.gov (United States)

    Azzaoui, Richard; Sobocinski, Jonathan; Maurel, Blandine; D'Elia, Piervito; Perrot, Céline; Bianchini, Aurélia; Guillou, Matthieu; Haulon, Stéphan

    2011-04-01

    Fenestrated stent-grafts allow for treatment of patients with juxtarenal aneurysms (JRA) when they present with contraindications for conventional treatment. The fenestrated module is a custom-made module, specially designed to fit a specific patient, using computed tomographic scan measurements, which entails manufacturing delay and high cost. The aim of our study was to evaluate the possibility to reproduce the interrenal aorta anatomy to design a standard fenestrated module that would fit the maximum number of patients with JRA. On a three-dimensional working station, we analyzed 289 preoperative computed tomographic scan results of patients with JRA and who were treated with fenestrated stent-grafts comprising two fenestrations for the renal arteries and a scallop for the superior mesenteric artery (SMA). On curvilinear reconstructions, we successively measured the interrenal aorta diameter, its orientation, as well as the height of each renal ostium, taking the ostium center of the SMA as a reference mark. Later, a statistical analysis of these measures distribution was performed so as to design a fenestrated module that would fit the maximum number of patients. The center of the left renal artery presented with a median orientation of 82.5° (range, 37.5-150) and a median distance of 9 mm (range, 0-30), in relation to the SMA ostium. The ostium center of the right renal artery presented with a median orientation of 285° (range, 240-337.5) and a median distance of 8 mm (range, 3-30), in relation to the SMA ostium. By positioning the current renal fenestrations (6-mm wide), on the basis of the calculated median positions, in our series, only 20% of the patients could be treated with a standard fenestrated module. Should the diameter of these fenestrations be increased by 10 mm, it would then be possible to treat 50% of our patients. The anatomy of the interrenal aorta and its branches is quite reproducible to design standard fenestrated stent-grafts that could

  3. Endovascular repair as a sole treatment in multiple aneurysms in patient with SLE

    International Nuclear Information System (INIS)

    Dineva, S.; Al-Amin, M.; Demetriou, S.; Tsetis, D.

    2013-01-01

    Full text: Introduction: Most aneurysms are local manifestations of systemic disease. For patients over 65 years the incidence of aneurysm of the abdominal aorta (AAA) is approximately 5-6% in men and 1-2 % for women. The presence of both the AAA and aneurysms in other location is even rarer, and this percentage is likely increase further in patients with systemic lupus erythematosus (SLE). What you will learn: We present a rare clinical case of endovascular treatment of multifocal aneurysm including post catheterization pseudoaneurysm. The patient is a 73 years old woman with a history of SLE and age-related comorbidity. Originally an endovascular treatment of aneurysms of the abdominal aorta and right common iliac artery was used. Two years later a successfully endovascular treatment of aneurysm of the right renal artery was conducted, which however is complicated by the formation of a pseudoaneurysm in access through the left femoral artery. The late one is again treated endovascular by placement of a covered stent after failure of percutaneous injection of 1000 UI thrombin. Discussion: Adult patients with a long history of SLE are unsuitable candidates for surgical treatment of aneurysmal disease, especially in its multifocal form. In our case we have taken multistep successful endovascular procedures, including technically hard placing of the stent at the site of the right renal aneurysms, and post catheterization pseudoaneurysm. Conclusion: Multifocal aneurysmal vascular changes due to macroangiopathia in SLE can be treated alone by endovascular means in multi-stages procedures

  4. EndoVascular and Hybrid Trauma Management (EVTM) for Blunt Innominate Artery Injury with Ongoing Extravasation

    International Nuclear Information System (INIS)

    Bilos, Linda; Pirouzram, Artai; Toivola, Asko; Vidlund, Mårten; Cha, Soon Ok; Hörer, Tal

    2017-01-01

    Innominate artery (IA) traumatic injuries are rare but life-threatening, with high mortality and morbidity. Open surgical repair is the treatment of choice but is technically demanding. We describe a case of blunt trauma to the IA with ongoing bleeding, treated successfully by combined (hybrid) endovascular and open surgery. The case demonstrates the immediate usage of modern endovascular and surgical tools as part of endovascular and hybrid trauma management.

  5. EndoVascular and Hybrid Trauma Management (EVTM) for Blunt Innominate Artery Injury with Ongoing Extravasation

    Energy Technology Data Exchange (ETDEWEB)

    Bilos, Linda, E-mail: linda.bilos@regionorebrolan.se; Pirouzram, Artai; Toivola, Asko; Vidlund, Mårten; Cha, Soon Ok; Hörer, Tal [Örebro University Hospital and Örebro University, Department of Cardiothoracic and Vascular Surgery, Faculty of Medicine and Health (Sweden)

    2017-01-15

    Innominate artery (IA) traumatic injuries are rare but life-threatening, with high mortality and morbidity. Open surgical repair is the treatment of choice but is technically demanding. We describe a case of blunt trauma to the IA with ongoing bleeding, treated successfully by combined (hybrid) endovascular and open surgery. The case demonstrates the immediate usage of modern endovascular and surgical tools as part of endovascular and hybrid trauma management.

  6. Clinical applications of robotic technology in vascular and endovascular surgery.

    Science.gov (United States)

    Antoniou, George A; Riga, Celia V; Mayer, Erik K; Cheshire, Nicholas J W; Bicknell, Colin D

    2011-02-01

    Emerging robotic technologies are increasingly being used by surgical disciplines to facilitate and improve performance of minimally invasive surgery. Robot-assisted intervention has recently been introduced into the field of vascular surgery to potentially enhance laparoscopic vascular and endovascular capabilities. The objective of this study was to review the current status of clinical robotic applications in vascular surgery. A systematic literature search was performed in order to identify all published clinical studies related to robotic implementation in vascular intervention. Web-based search engines were searched using the keywords "surgical robotics," "robotic surgery," "robotics," "computer assisted surgery," and "vascular surgery" or "endovascular" for articles published between January 1990 and November 2009. An evaluation and critical overview of these studies is reported. In addition, an analysis and discussion of supporting evidence for robotic computer-enhanced telemanipulation systems in relation to their applications in laparoscopic vascular and endovascular surgery was undertaken. Seventeen articles reporting on clinical applications of robotics in laparoscopic vascular and endovascular surgery were detected. They were either case reports or retrospective patient series and prospective studies reporting laparoscopic vascular and endovascular treatments for patients using robotic technology. Minimal comparative clinical evidence to evaluate the advantages of robot-assisted vascular procedures was identified. Robot-assisted laparoscopic aortic procedures have been reported by several studies with satisfactory results. Furthermore, the use of robotic technology as a sole modality for abdominal aortic aneurysm repair and expansion of its applications to splenic and renal artery aneurysm reconstruction have been described. Robotically steerable endovascular catheter systems have potential advantages over conventional catheterization systems

  7. Dual-energy CT for detection of endoleaks after endovascular abdominal aneurysm repair: usefulness of colored iodine overlay.

    Science.gov (United States)

    Ascenti, Giorgio; Mazziotti, Silvio; Lamberto, Salvatore; Bottari, Antonio; Caloggero, Simona; Racchiusa, Sergio; Mileto, Achille; Scribano, Emanuele

    2011-06-01

    The purpose of our study was to evaluate the value of dual-source dual-energy CT with colored iodine overlay for detection of endoleaks after endovascular abdominal aortic aneurysm repair. We also calculated the potential dose reduction by using a dual-energy CT single-phase protocol. From November 2007 to November 2009, 74 patients underwent CT angiography 2-7 days after endovascular repair during single-energy unenhanced and dual-energy venous phases. By using dual-energy software, the iodine overlay was superimposed on venous phase images with different percentages ranging between 0 (virtual unenhanced images) and 50-75% to show the iodine in an orange color. Two blinded readers evaluated the data for diagnosis of endoleaks during standard unenhanced and venous phase images (session 1, standard of reference) and virtual unenhanced and venous phase images with colored iodine overlay images (session 2). We compared the effective dose radiation of a single-energy biphasic protocol with that of a single-phase dual-energy protocol. The diagnostic accuracy of session 2 was calculated. The mean dual-energy effective dose was 7.27 mSv. By using a dual-energy single-phase protocol, we obtained a mean dose reduction of 28% with respect to a single-energy biphasic protocol. The diagnostic accuracy of session 2 was: 100% sensitivity, 100% specificity, 100% negative predictive value, and 100% positive predictive value. Statistically significant differences in the level of confidence for endoleak detection between the two sessions were found by reviewers for scores 3-5. Dual-energy CT with colored iodine overlay is a useful diagnostic tool in endoleak detection. The use of a dual-energy single-phase study protocol will lower radiation exposure to patients.

  8. Flow and wall shear stress characterization after endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model.

    Science.gov (United States)

    Boersen, Johannes T; Groot Jebbink, Erik; Versluis, Michel; Slump, Cornelis H; Ku, David N; de Vries, Jean-Paul P M; Reijnen, Michel M P J

    2017-12-01

    Endovascular aneurysm repair (EVAR) with a modular endograft has become the preferred treatment for abdominal aortic aneurysms. A novel concept is endovascular aneurysm sealing (EVAS), consisting of dual endoframes surrounded by polymer-filled endobags. This dual-lumen configuration is different from a bifurcation with a tapered trajectory of the flow lumen into the two limbs and may induce unfavorable flow conditions. These include low and oscillatory wall shear stress (WSS), linked to atherosclerosis, and high shear rates that may result in thrombosis. An in vitro study was performed to assess the impact of EVAR and EVAS on flow patterns and WSS. Four abdominal aortic aneurysm phantoms were constructed, including three stented models, to study the influence of the flow divider on flow (Endurant [Medtronic, Minneapolis, Minn], AFX [Endologix, Irvine, Calif], and Nellix [Endologix]). Experimental models were tested under physiologic resting conditions, and flow was visualized with laser particle imaging velocimetry, quantified by shear rate, WSS, and oscillatory shear index (OSI) in the suprarenal aorta, renal artery (RA), and common iliac artery. WSS and OSI were comparable for all models in the suprarenal aorta. The RA flow profile in the EVAR models was comparable to the control, but a region of lower WSS was observed on the caudal wall compared with the control. The EVAS model showed a stronger jet flow with a higher shear rate in some regions compared with the other models. Small regions of low WSS and high OSI were found near the distal end of all stents in the common iliac artery compared with the control. Maximum shear rates in each region of interest were well below the pathologic threshold for acute thrombosis. The different stent designs do not influence suprarenal flow. Lower WSS is observed in the caudal wall of the RA after EVAR and a higher shear rate after EVAS. All stented models have a small region of low WSS and high OSI near the distal outflow

  9. Aneurysmal subarachnoid hemorrhage with concomitant posterior communicating artery fenestration.

    Science.gov (United States)

    Weiner, Gregory M; Grandhi, Ramesh; Zwagerman, Nathan T; Agarwal, Nitin; Friedlander, Robert M

    2015-02-01

    Fenestrations of the posterior communicating artery (PCoA) are extremely rare. Associated aneurysms have only been documented three times in the literature, and none associated with a subarachnoid hemorrhage. We describe a 52-year-old female who presented with a subarachnoid hemorrhage secondary to a ruptured saccular aneurysm at the proximal limb of a fenestrated right PCoA. The patient was also found to have bilateral middle cerebral artery (MCA) aneurysms. Surgical management included surmising the etiology of the subarachnoid hemorrhage with subsequent clipping of both the right PCoA and MCA aneurysm. The potential embryological mechanisms leading to a PCoA fenestration are discussed.

  10. Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

    International Nuclear Information System (INIS)

    Chan, Gabriel; Quek, Lawrence Hwee Han; Tan, Glenn Leong Wei; Pua, Uei

    2016-01-01

    BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

  11. Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Gabriel, E-mail: dr.changabriel@gmail.com; Quek, Lawrence Hwee Han, E-mail: lawrence-quek@ttsh.com.sg [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore); Tan, Glenn Leong Wei, E-mail: glenn-tan@ttsh.com.sg [Tan Tock Seng Hospital, Department of General Surgery (Singapore); Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2016-07-15

    BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

  12. Multimodality Imaging Approach towards Primary Aortic Sarcomas Arising after Endovascular Abdominal Aortic Aneurysm Repair: Case Series Report

    Energy Technology Data Exchange (ETDEWEB)

    Kamran, Mudassar, E-mail: kamranm@mir.wustl.edu; Fowler, Kathryn J., E-mail: fowlerk@mir.wustl.edu; Mellnick, Vincent M., E-mail: mellnickv@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States); Sicard, Gregorio A., E-mail: sicard@wudosis.wustl.edu [Washington University School of Medicine, Department of Surgery (United States); Narra, Vamsi R., E-mail: narrav@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States)

    2016-06-15

    Primary aortic neoplasms are rare. Aortic sarcoma arising after endovascular aneurysm repair (EVAR) is a scarce subset of primary aortic malignancies, reports of which are infrequent in the published literature. The diagnosis of aortic sarcoma is challenging due to its non-specific clinical presentation, and the prognosis is poor due to delayed diagnosis, rapid proliferation, and propensity for metastasis. Post-EVAR, aortic sarcomas may mimic other more common aortic processes on surveillance imaging. Radiologists are rarely knowledgeable about this rare entity for which multimodality imaging and awareness are invaluable in early diagnosis. A series of three pathologically confirmed cases are presented to display the multimodality imaging features and clinical presentations of aortic sarcoma arising after EVAR.

  13. Fusiform aneurysm associated with fenestration of the posterior communicating artery.

    Science.gov (United States)

    Baba, Shiro; Fukuda, Yuutaka; Mizota, Shingo; Hayashi, Kentaro; Suyama, Kazuhiko; Nagata, Izumi

    2010-01-01

    A 62-year-old male presented with a rare case of fenestration of the supraclinoid segment of the internal carotid artery (ICA) at the origin of the posterior communicating artery (PCoA). The patient had a fusiform aneurysm at the proximal branch of the PCoA, which was successfully clipped, sparing the anterograde blood flow. The double origin and fenestration of the PCoA branching off at the C(2) segment of the left ICA suggested that this anomalous fenestration might have developed as the origin of the PCoA rather than the supraclinoid ICA during the early embryonal stage.

  14. Human Thiel-Embalmed Cadaveric Aortic Model with Perfusion for Endovascular Intervention Training and Medical Device Evaluation.

    Science.gov (United States)

    McLeod, Helen; Cox, Ben F; Robertson, James; Duncan, Robyn; Matthew, Shona; Bhat, Raj; Barclay, Avril; Anwar, J; Wilkinson, Tracey; Melzer, Andreas; Houston, J Graeme

    2017-09-01

    The purpose of this investigation was to evaluate human Thiel-embalmed cadavers with the addition of extracorporeal driven ante-grade pulsatile flow in the aorta as a model for simulation training in interventional techniques and endovascular device testing. Three human cadavers embalmed according to the method of Thiel were selected. Extracorporeal pulsatile ante-grade flow of 2.5 L per min was delivered directly into the aorta of the cadavers via a surgically placed connection. During perfusion, aortic pressure and temperature were recorded and optimized for physiologically similar parameters. Pre- and post-procedure CT imaging was conducted to plan and follow up thoracic and abdominal endovascular aortic repair as it would be in a clinical scenario. Thoracic endovascular aortic repair (TEVAR) and endovascular abdominal repair (EVAR) procedures were conducted in simulation of a clinical case, under fluoroscopic guidance with a multidisciplinary team present. The Thiel cadaveric aortic perfusion model provided pulsatile ante-grade flow, with pressure and temperature, sufficient to conduct a realistic simulation of TEVAR and EVAR procedures. Fluoroscopic imaging provided guidance during the intervention. Pre- and post-procedure CT imaging facilitated planning and follow-up evaluation of the procedure. The human Thiel-embalmed cadavers with the addition of extracorporeal flow within the aorta offer an anatomically appropriate, physiologically similar robust model to simulate aortic endovascular procedures, with potential applications in interventional radiology training and medical device testing as a pre-clinical model.

  15. Open and endovascular aneurysm repair in the Society for Vascular Surgery Vascular Quality Initiative.

    Science.gov (United States)

    Spangler, Emily L; Beck, Adam W

    2017-12-01

    The Society for Vascular Surgery Vascular Quality Initiative is a patient safety organization and a collection of procedure-based registries that can be utilized for quality improvement initiatives and clinical outcomes research. The Vascular Quality Initiative consists of voluntary participation by centers to collect data prospectively on all consecutive cases within specific registries which physicians and centers elect to participate. The data capture extends from preoperative demographics and risk factors (including indications for operation), through the perioperative period, to outcomes data at up to 1-year of follow-up. Additionally, longer-term follow-up can be achieved by matching with Medicare claims data, providing long-term longitudinal follow-up for a majority of patients within the Vascular Quality Initiative registries. We present the unique characteristics of the Vascular Quality Initiative registries and highlight important insights gained specific to open and endovascular abdominal aortic aneurysm repair. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Case report and review of the literature total endovascular repair of acute ascending aortic rupture: a case report and review of the literature.

    Science.gov (United States)

    McCallum, John C; Limmer, Karl K; Perricone, Anthony; Bandyk, Dennis; Kansal, Nikhil

    2013-07-01

    Thoracic aortic endografting has been successfully implemented to treat aneurysmal disease of the distal aortic arch and descending thoracic aorta. Although there are reports of ascending aortic endovascular interventions, the total endovascular repair of a ruptured ascending aorta secondary to a Type A dissection has not been described. We report the case of a 77-year-old patient who presented with a ruptured ascending aortic aneurysm secondary to degeneration of a Stanford type A aortic dissection. His surgical history was significant for orthotropic heart transplant 19 years prior. The dissection, aneurysm, and rupture occurred in the native aorta distal to the ascending aortic suture line. At presentation, he was hemodynamically unstable with a right hemothorax. We placed 3 Medtronic Talent Thoracic Stent Graft devices (Medtronic Inc, Minneapolis, MN) across the suture line in the ascending aorta, excluding the rupture. The patient survived and has been followed to 25 months.

  17. Emergency Endovascular Treatment of Abdominal Aortic Aneurysms: Feasibility and Results

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Fontana, Federico; Caronno, Roberto; Castelli, Patrizio; Cuffari, Salvatore; Fugazzola, Carlo

    2006-01-01

    Purpose. To assess the feasibility and effectiveness of emergency endovascular treatment of abdominal aortic aneurysms (AAAs). Methods. During 36 months we treated, on an emergency basis, 30 AAAs with endovascular exclusion. In 21 hemodynamically stable patients preoperative CT angiography (CTA) was performed to confirm the diagnosis and to plan the treatment; 9 patients with hemorrhagic shock were evaluated with angiography performed in the operating room. Twenty-two Excluder (Gore) and 8 Zenith (Cook) stent-grafts (25 bifurcated and 5 aorto-uni-iliac) were used. The follow-up was performed by CTA at 1, 3, 6, and 12 months. Results. Technical success was achieved in 100% of cases with a 10% mortality rate. The total complication rate was 23% (5 increases in serum creatinine level and 2 wound infections). During the follow-up, performed in 27 patients (1-36 months, mean 15.2 months), 4 secondary endoleaks (15%) (3 type II, 2 spontaneously thrombosed and 1 under observation, and 1 type III treated by iliac extender insertion) and 1 iliac leg occlusion (treated with femoro-femoral bypass) occurred. We observed a shrinkage of the aneurysmal sac in 8 of 27 cases and stability in 19 of 27 cases; we did not observe any endotension. Conclusions. Endovascular repair is a good option for emergency treatment of AAAs. The team's experience allows correct planning of the procedure in emergency situations also, with technical results comparable with elective repair. In our experience the bifurcated stent-graft is the device of choice in patients with suitable anatomy because the procedure is less time-consuming than aorto-uni-iliac stent-grafting with surgical crossover, allowing faster aneurysm exclusion. However, further studies are required to demonstrate the long-term efficacy of endovascular repair compared with surgical treatment

  18. The Burden of Hard Atherosclerotic Plaques Does Not Promote Endoleak Development After Endovascular Aortic Aneurysm Repair: A Risk Stratification

    International Nuclear Information System (INIS)

    Petersen, Johannes; Glodny, Bernhard

    2011-01-01

    Purpose: To objectify the influence of the atherosclerotic burden in the proximal landing zone on the development of endoleaks after endovascular abdominal aortic aneurysm repair (EVAR) or thoracic endovascular aneurysm repair (TEVAR) using objective aortic calcium scoring (ACS). Materials and Methods: This retrospective observation study included 267 patients who received an aortic endograft between 1997 and 2010 and for whom preoperative computed tomography (CT) was available to perform ACS using the CT-based V600 method. The mean follow-up period was 2 ± 2.3 years. Results: Type I endoleaks persisted in 45 patients (16.9%), type II in 34 (12.7%), type III in 8 (3%), and type IV or V in 3 patients, respectively (1.1% each). ACS in patients with type I endoleaks was not increased: 0.029 ± 0.061 ml compared with 0.075 ± 0.1349 ml in the rest of the patients, (p > 0.05; Whitney–Mann U-Test). There were significantly better results for the indication “traumatic aortic rupture” than for the other indications (p < 0.05). In multivariate logistic regression analyses, age was an independent risk factor for the development of type I endoleaks in the thoracic aorta (Wald 9.5; p = 0.002), whereas ACS score was an independent protective factor (Wald 6.9; p = 0.009). In the abdominal aorta, neither age nor ACS influenced the development of endoleaks. Conclusion: Contrary to previous assumptions, TEVAR and EVAR can be carried out without increasing the risk of an endoleak of any type, even if there is a high atherosclerotic “hard-plaque” burden of the aorta. The results are significantly better for traumatic aortic.

  19. Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: an in vitro study

    International Nuclear Information System (INIS)

    Springer, Fabian; Pfeffer, Joachim-Georg; Schmitz-Rode, Thomas; Schlierf, Roland; Schnakenberg, Uwe; Mahnken, Andreas H.

    2007-01-01

    A feasibility study on a completely digital telemetric pressure sensor (TPS) to detect endoleaks was performed in an in vitro model of an abdominal aortic aneurysm (AAA). An endovascular-stented AAA silicone model with different types (I-III) and sizes (3-11 French) of endoleaks was created and pulsatile pressure was applied with physiological flow and pressure rates [mean intraaortic pressure (IAP): 95-130 mmHg] and different degrees of thrombosis of the aneurysm sac. Aneurysm sac pressure (ASP) was measured with the TPS and with wired pressure sensors (WPS) as a reference. Statistical analysis included paired t-test, Pearson's correlation analysis and Bland-Altman plots. After opening an endoleak, the mean ASP increased significantly (P < 0.0001) from 15 to almost 95% of the mean IAP depending on endoleak type and size. ASP could be measured accurately with the TPS and the WPS. The telemetric and wired ASP increase showed a high Pearson's correlation coefficient (r) for a non-thrombosed (r 0.97) and a thrombosed (r = 0.96) aneurysm sac. In an in vitro silicone model, the newly designed telemetric pressure sensor was able to detect the occurrence of an endoleak in a non-invasive way and might be a valuable device for follow-up of endovascular AAA repair. (orig.)

  20. Successful Aortic Banding for Type IA Endoleak Due to Neck Dilatation after Endovascular Abdominal Aortic Aneurysm Repair: Case Report.

    Science.gov (United States)

    Tashima, Yasushi; Tamai, Koichi; Shirasugi, Takehiro; Sato, Kenichiro; Yamamoto, Takahiro; Imamura, Yusuke; Yamaguchi, Atsushi; Adachi, Hideo; Kobinata, Toshiyuki

    2017-09-25

    A 69-year-old man with a type IA endoleak that developed approximately 21 months after endovascular abdominal aortic aneurysm repair (EVAR) of a 46 mm diameter aneurysm was referred to our department. He had impaired renal function, Parkinson's disease, and previous cerebral infarction. Computed tomography angiography showed a type IA endoleak with neck dilatation and that the aneurysm had grown to 60 mm in diameter. We decided to perform aortic banding. The type IA endoleak disappeared after banding and the patient was discharged on postoperative day 10. Aortic banding may be effective for type IA endoleak after EVAR and less invasive for high-risk patients in particular.

  1. Evaluating Fenestration Products for Zero-Energy Buildings: Issuesfor Discussion

    Energy Technology Data Exchange (ETDEWEB)

    Arasteh, Dariush; Curcija, Charlie; Huang, Joe; Huizenga,Charlie; Kohler, Christian

    2006-07-25

    Computer modeling to determine fenestration product energy properties (U-factor, SHGC, VT) has emerged as the most cost-effective and accurate means to quantify them. Fenestration product simulation tools have been effective in increasing the use of low-e coatings and gas fills in insulating glass and in the widespread use of insulating frame designs and materials. However, for more efficient fenestration products (low heat loss products, dynamic products, products with non-specular optical characteristics, light re-directing products) to achieve widespread use, fenestration modeling software needs to be improved. This paper addresses the following questions: (1) Are the current properties (U, SHGC, VT) calculated sufficient to compare and distinguish between windows suitable for Zero Energy Buildings and conventional window products? If not, what data on the thermal and optical performance, on comfort, and on peak demand of windows is needed. (2) Are the algorithms in the tools sufficient to model the thermal and optical processes? Are specific heat transfer and optical effects not accounted for? Is the existing level of accuracy enough to distinguish between products designed for Zero Energy Buildings? Is the current input data adequate?

  2. Minimally Invasive Technique for PMMA Augmentation of Fenestrated Screws

    Directory of Open Access Journals (Sweden)

    Jan-Helge Klingler

    2015-01-01

    Full Text Available Purpose. To describe the minimally invasive technique for cement augmentation of cannulated and fenestrated screws using an injection cannula as well as to report its safety and efficacy. Methods. A total of 157 cannulated and fenestrated pedicle screws had been cement-augmented during minimally invasive posterior screw-rod spondylodesis in 35 patients from January to December 2012. Retrospective evaluation of cement extravasation and screw loosening was carried out in postoperative plain radiographs and thin-sliced triplanar computed tomography scans. Results. Twenty-seven, largely prevertebral cement extravasations were detected in 157 screws (17.2%. None of the cement extravasations was causing a clinical sequela like a new neurological deficit. One screw loosening was noted (0.6% after a mean follow-up of 12.8 months. We observed no cementation-associated complication like pulmonary embolism or hemodynamic insufficiency. Conclusions. The presented minimally invasive cement augmentation technique using an injection cannula facilitates convenient and safe cement delivery through polyaxial cannulated and fenestrated screws during minimally invasive screw-rod spondylodesis. Nevertheless, the optimal injection technique and design of fenestrated screws have yet to be identified. This trial is registered with German Clinical Trials DRKS00006726.

  3. Application of rapid artificial cardiac pacing in thoracic endovascular aortic repair in aged patients

    Directory of Open Access Journals (Sweden)

    Chen J

    2013-12-01

    Full Text Available Jun Chen,1,* Wenhui Huang,2,* Songyuan Luo,2,* Dahao Yang,1 Zhengrong Xu,1 Jianfang Luo21Department of Angiocardiopathy, Affiliated Baoan Hospital of Southern Medical University, Shenzhen City, People's Republic of China; 2Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, People's Republic of China*These authors contributed equally to this workObjective: To compare the safety, efficacy, and impact on stent graft positioning between rapid artificial cardiac pacing (RACP, induced hypotension and sodium nitroprusside (SNP induced hypotension during thoracic endovascular aortic repair (TEVAR for Stanford B aortic dissection.Methods: One hundred and sixty-eight patients, who were diagnosed with Stanford B aortic dissection and who underwent selective TEVAR in Guangdong General Hospital and the People's Hospital of Baoan District, Shenzhen, People's Republic of China, were enrolled in this study. Patients were randomly divided into a RACP group (n=77 and a SNP group (n=91. During localization and deployment of the stent graft, hypotension was induced by RACP or intravenous SNP, according to randomization. Hemodynamics, landing precision (deviation from planned placement site, duration of procedure, renal function, neurocognitive function, and incidence of endoleaks and paraplegia/hemiplegia were compared. Except for methods of inducing hypotension, TEVAR was performed according to the same protocol in each group.Results: RACP was successfully performed in all patients assigned to the RACP group. Compared with the SNP group, blood pressure was significantly lower (43±5 versus 81±6 mmHg, P=0.003 and the restoration time of blood pressure and the operation duration were significantly shorter (7±2 versus 451±87 seconds, P<0.001; 87±15 versus 106±18 minutes, P<0.001, respectively in the RACP group. Stent graft localization/deployment was more precise in the RACP

  4. Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting

    International Nuclear Information System (INIS)

    Riga, Celia V.; Bicknell, Colin D.; Wallace, Daniel; Hamady, Mohamad; Cheshire, Nicholas

    2009-01-01

    To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.

  5. Epidemiology of abdominal aortic aneurysms in a Chinese population during introduction of endovascular repair, 1994 to 2013: A retrospective observational study.

    Science.gov (United States)

    Tam, Greta; Chan, Yiu Che; Chong, Ka Chun; Lee, Kam Pui; Cheung, Grace Chung-Yan; Cheng, Stephen Wing-Keung

    2018-03-01

    The aim of this study was to examine changes in abdominal aortic aneurysm repair and mortality during a period when endovascular aneurysm repair (EVAR) was introduced.Open repair surgery was the mainstay of treatment for abdominal aortic aneurysm (AAA), but EVAR is increasingly utilized. Studies in the Western population have reported improved short-term or postoperative mortality and shorter length of hospital stay with EVAR. However, scant data are available in the Chinese population.We conducted a retrospective observational study using the database of the Hospital Authority, which provides public health care to most of the Hong Kong population. AAA patients admitted to public hospitals for intact repair or rupture from 1994 to 2013 were included in this study. We calculated the incidence of ruptured AAA, annual repair rates according to type of AAA and surgery, as well as death rates (operative and overall short-term). We calculated whether there were significant changes over time and compared short-term mortality between open surgery and EVAR.One thousand eight hundred eighty-five patients were admitted for intact repair and 1306 patients were admitted for AAA rupture, of whom 795 underwent rupture repair. Intact repair rates significantly increased in all age groups (7.3-37.8%, P short-term AAA-related deaths decreased by more than half (73% in 1994 to 24% in 2013, P Short-term mortality was significantly lower for EVAR than for open repair (17.2% vs 40.3%, P Short-term AAA-related deaths have declined likely due to decreased operative mortality and rupture deaths during the period of EVAR introduction and expansion.

  6. New Technique for the Preservation of the Left Common Carotid Artery in Zone 2a Endovascular Repair of Thoracic Aortic Aneurysm

    International Nuclear Information System (INIS)

    Juszkat, Robert; Kulesza, Jerzy; Zarzecka, Anna; Jemielity, Marek; Staniszewski, Ryszard; Majewski, Wacław

    2011-01-01

    To describe a technique for the preservation of the left common carotid artery (CCA) in zone 2 endovascular repair of thoracic aortic aneurysm. This technique involves the placement of a guide wire into the left CCA via the right brachial artery before stent graft deployment to enable precise visualization and protection of the left CCA during the whole procedure. Of the 107 patients with thoracic endovascular aortic repair in our study, 32 (30%) had the left subclavian artery intentionally covered (landing zone 2). Eight (25%) of those 32 had landing zone 2a—the segment distally the origin of the left CCA, halfway between the origin of the left CCA and the left subclavian artery. In all patients, a guide wire was positioned into the left CCA via the right brachial artery before stent graft deployment. It is a retrospective study in design. In seven patients, stent grafts were positioned precisely. In the remaining patient, the positioning was imprecise; the origin of the left CCA was partially covered by the graft. A stent was implanted into the left CCA to restore the flow into the vessel. All procedures were performed successfully. The technique of placing a guide wire into the left CCA via the right brachial artery before stent graft deployment is a safe and effective method that enables the precise visualization of the left CCA during the whole procedure. Moreover, in case of inadvertent complete or partial coverage of the origin of the left CCA, it supplies safe and quick access to the artery for stent implantation.

  7. Endovascular stent graft treatment of acute thoracic aortic transections due to blunt force trauma.

    LENUS (Irish Health Repository)

    Bjurlin, Marc A

    2012-02-01

    Endovascular stent graft treatment of acute thoracic aortic transections is an encouraging minimally invasive alternative to open surgical repair. Between 2006 and 2008, 16 patients with acute thoracic aortic transections underwent evaluation at our institution. Seven patients who were treated with an endovascular stent graft were reviewed. The mean Glasgow Coma Score was 13.0, probability of survival was .89, and median injury severity score was 32. The mean number of intensive care unit days was 7.7, mean number of ventilator support days was 5.4, and hospital length of stay was 10 days. Mean blood loss was 285 mL, and operative time was 143 minutes. Overall mortality was 14%. Procedure complications were a bleeding arteriotomy site and an endoleak. Endovascular treatment of traumatic thoracic aortic transections appears to demonstrate superior results with respect to mortality, blood loss, operative time, paraplegia, and procedure-related complications when compared with open surgical repair literature.

  8. Endovascular treatment of type B dissection in patients with Marfan syndrome: mid-term outcomes and aortic remodeling.

    Science.gov (United States)

    Eid-Lidt, Guering; Gaspar, Jorge; Meléndez-Ramírez, Gabriela; Cervantes S, Jorge; González-Pacheco, Hector; Dámas de Los Santos, Félix; Meave-González, Aloha; Ramírez Marroquín, Samuel

    2013-12-01

    To evaluate the mid-term outcomes, and the aortic remodeling in Marfan syndrome (MFS) patients with type B dissection that were treated with endovascular repair. MFS is a relative contraindication to thoracic endovascular aortic repair (TEVAR). Mid-term aortic outcomes data in MFS after TEVAR are limited, and the occurrence of late events remains unclear. Of 89 patients that underwent TEVAR between September 2002 and February 2011, 10 patients with mid-term follow-up fulfilled the Ghent criteria for MFS and complicated type B dissection. High risk for open surgery was documented in 90%. The mean age was 35.1 ± 9.4 years and all patients presented with acute aortic syndrome complicating a chronic type B dissection (DeBakey type IIIb). Five patients underwent a Bentall surgical procedure previous to endovascular repair, and in four patients initial TEVAR was followed by surgery of the ascending aorta. Treatment was limited to endovascular repair in only one patient. In-hospital mortality was 10%. At a mean follow-up of 59.6 ± 38.9 months, the cumulated mortality was of 20% and late mortality 11.1%. The rate of secondary endoleak was 44.4%, and late reintervention of 33.3%. Survival freedom from cardiovascular death at 8 years was 80.0%, and positive remodeling was documented in 37.5% of patients. Our results suggest that TEVAR is feasible, safe, and associated with a high reintervention rate and reduced rate of positive aortic remodeling in patients with Marfan syndrome. Survival at 8 years was comparable to contemporary series of open repair. Copyright © 2013 Wiley Periodicals, Inc.

  9. Endovascular stent-graft management of thoracic aortic diseases

    International Nuclear Information System (INIS)

    Dake, Michael D.

    2001-01-01

    The traditional standard therapy for descending thoracic aortic aneurysm (TAA) is open operative repair with graft replacement of the diseased aortic segment. Despite important advances in surgical techniques, anesthetic management, and post-operative care over the last 30 years, the mortality and morbidity of surgery remains considerable, especially in patients at high risk for thoracotomy because of coexisting severe cardiopulmonary abnormalities or other medical diseases. The advent of endovascular stent-graft technology provides an alternative to open surgery for selected patients with TAA. The initial experience suggests that stent-graft therapy potentially may reduce the operative risk, hospital stay and procedural expenses of TAA repair. These potential benefits are especially attractive for patients at high risk for open TAA repair. Current results of endovascular TAA therapy document operative mortalities of between 0 and 4%, aneurysm thrombosis in 90 and 100% of cases, and paraplegia as a complication in 0 and 1.6% of patients. The early success of stent-graft repair of TAA has fostered the application of these devices for the management of a wide variety of thoracic aortic pathologies, including acute and chronic dissection, intramural hematoma, penetrating ulcer, traumatic injuries, and other diseases. The results of prospective controlled trials that compare the outcomes of stent-graft therapy with those of surgical treatment in patients with specific types of aortic disease are anxiously awaited before recommendations regarding the general use of these new devices can be made with confidence

  10. Endovascular Repair of a Perforation of the Vena Caval Wall Caused by the Retrieval of a Gunther Tulip Filter After Long-Term Implantation

    International Nuclear Information System (INIS)

    Morishita, Hiroyuki; Yamagami, Takuji; Matsumoto, Tomohiro; Takeuchi, Yoshito; Sato, Osamu; Nishimura, Tsunehiko

    2011-01-01

    Symptomatic penetration of the inferior vena cava (IVC) wall reportedly occurs in 0.3% of patients in whom a filter has been implanted, and it causes injury to the adjacent structures (Bogue et al. in Pediatr Radiol 39(10):1110–1113, 1; Brzezinski et al. in Burns 32(5):640–643, 2). We succeeded in the endovascular repair of perforation of the IVC wall occurring during the retrieval of a penetrated Gunther tulip vena cava filter (Cook, Bjaeverskov, Denmark) after long-term implantation.

  11. Application of thoracic endovascular aortic repair (TEVAR) in treating dwarfism with Stanford B aortic dissection

    Science.gov (United States)

    Qiu, Jian; Cai, Wenwu; Shu, Chang; Li, Ming; Xiong, Qinggen; Li, Quanming; Li, Xin

    2018-01-01

    Abstract Rationale: To apply thoracic endovascular aortic repair (TEVAR) to treat dwarfism complicated with Stanford B aortic dissection. Patient concerns: In this report, we presented a 63-year-old male patient of dwarfism complicated with Stanford B aortic dissection successfully treated with TEVAR. Diagnoses: He was diagnosed with dwarfism complicated with Stanford B aortic dissection. Interventions: After conservative treatment, the male patient underwent TEVAR at 1 week after hospitalization. After operation, he presented with numbness and weakness of his bilateral lower extremities, and these symptoms were significantly mitigated after effective treatment. At 1- and 3-week after TEVAR, the aorta status was maintained stable and restored. Outcomes: The patient obtained favorable clinical prognosis and was smoothly discharged. During subsequent follow-up, he remained physically stable. Lessons: TEVAR is probably an option for treating dwarfism complicated with Stanford B aortic dissection, which remains to be validated by subsequent studies with larger sample size. PMID:29703033

  12. Hemodynamic and Anatomic Predictors of Renovisceral Stent-Graft Occlusion Following Chimney Endovascular Repair of Juxtarenal Aortic Aneurysms.

    Science.gov (United States)

    Tricarico, Rosamaria; He, Yong; Laquian, Liza; Scali, Salvatore T; Tran-Son-Tay, Roger; Beck, Adam W; Berceli, Scott A

    2017-12-01

    To identify anatomic and hemodynamic changes associated with impending visceral chimney stent-graft occlusion after endovascular aneurysm repair (EVAR) with the chimney technique (chEVAR). A retrospective evaluation was performed of computed tomography scans from 41 patients who underwent juxtarenal chEVAR from 2008 to 2012 to identify stent-grafts demonstrating conformational changes following initial placement. Six subjects (mean age 74 years; 3 men) were selected for detailed reconstruction and computational hemodynamic analysis; 4 had at least 1 occluded chimney stent-graft. This subset of repairs was systematically analyzed to define the anatomic and hemodynamic impact of these changes and identify signature patterns associated with impending renovisceral stent-graft occlusion. Spatial and temporal analyses of cross-sectional area, centerline angle, intraluminal pressure, and wall shear stress (WSS) were performed within the superior mesenteric and renal artery chimney grafts used for repair. Conformational changes in the chimney stent-grafts and associated perturbations, in both local WSS and pressure, were responsible for the 5 occlusions in the 13 stented branches. Anatomic and hemodynamic signatures leading to occlusion were identified within 1 month postoperatively, with a lumen area 25 Pa/mm (p=0.03), and systolic WSS >45 Pa (p=0.03) associated with future chimney stent-graft occlusion. Chimney stent-grafts at increased risk for occlusion demonstrated anatomic and hemodynamic signatures within 1 month of juxtarenal chEVAR. Analysis of these parameters in the early postoperative period may be useful for identifying and remediating these high-risk stent-grafts.

  13. Endovascular repair of an iliac arteriovenous fistula secondary to perforation from a common iliac aneurysm in a patient with Ehler-Danlos syndrome.

    Science.gov (United States)

    Sala Almonacil, Vicente Andrés; Zaragozá García, José Miguel; Gómez Palonés, Francisco Julián; Plaza Martínez, Ángel; Ortíz Monzón, Eduardo

    2012-08-01

    Type IV Ehler-Danlos syndrome (EDS) patients are prone to life-threatening vascular complications. Surgical management of those complications is challenging owing to vessel wall fragility, which may result in hemorrhagic events and high mortality rates. Here we report a case of left common iliac aneurysm perforation of the ipsilateral iliac vein repaired using endovascular technique in a patient with EDS. A 54-year-old patient presented with heart failure symptoms that evolved over 1 week in association with left leg edema and steal syndrome due to a perforation of the left iliac vein caused by a left common iliac aneurysm. A thrombosed right common iliac aneurysm and several other visceral and peripheral aneurysms were discovered on computed tomographic scan at admission. An aortouniiliac stent graft was used to seal the fistula. After 18 months of follow-up, the patient remained asymptomatic. We suggest that endovascular therapy is useful to manage vascular complications in patients with EDS. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  14. Endovascular Treatment of Various Aortic Pathologies: Review of the Latest Data and Technologies.

    Science.gov (United States)

    Maeda, Koji; Ohki, Takao; Kanaoka, Yuji

    2018-06-01

    The technologies and innovations applicable to endovascular treatment for complex aortic pathologies have progressed rapidly over the last two decades. Although the initial outcomes of an endovascular aortic repair have been excellent, as long-term data became available, complications including endoleaks, endograft migration, and endograft infection have become apparent and are of concern. Previously, the indication for endovascular therapy was restricted to descending thoracic aortic aneurysms and abdominal aortic aneurysms. However, its indication has expanded along with the improvement of techniques and devices, and currently, it has become possible to treat pararenal aortic aneurysms and Crawford type 4 thoracoabdominal aortic aneurysm (TAAA) using the off-the-shelf devices. Additionally, custom-made devices allow for the treatment of arch or more extensive TAAAs. Endovascular treatment is applied not only to aneurysms but also to acute/chronic dissections. However, long-term outcomes are still unclear. This article provides an overview of available devices and the results of endovascular treatment for various aortic pathologies.

  15. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    Science.gov (United States)

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P stents was greater than that of all three endovascular stents (P stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  16. Editor's Choice - Late Open Surgical Conversion after Endovascular Abdominal Aortic Aneurysm Repair.

    Science.gov (United States)

    Kansal, Vinay; Nagpal, Sudhir; Jetty, Prasad

    2018-02-01

    Late open surgical conversion following endovascular aneurysm repair (EVAR) may occur more frequently after performing EVAR in anatomy outside the instructions for use (IFU). This study reviews predictors and outcomes of late open surgical conversion for failed EVAR. This retrospective cohort study reviewed all EVARs performed at the Ottawa Hospital between January 1999 and May 2015. Open surgical conversions >1 month post EVAR were identified. Variables analysed included indication for conversion, pre-intervention AAA anatomy, endovascular device and configuration, operative technique, re-interventions, complications, and death. Of 1060 consecutive EVARs performed, 16 required late open surgical conversion. Endografts implanted were Medtronic Talent (n = 8, 50.0%), Medtronic Endurant (n = 3, 18.8%), Cook Zenith (n = 4, 25.0%), and Terumo Anaconda (n = 1, 6.2%). Eleven grafts were bifurcated (68.8%), five were aorto-uni-iliac (31.2%). The median time to open surgical conversion was 3.1 (IQR 1.0-5.2) years. There was no significant difference in pre-EVAR rupture status (1.4% elective, 2.1% ruptured, p = .54). Indications for conversion included: Type 1 endoleak with sac expansion (n = 4, 25.0%), Type 2 endoleak with expansion (n = 2, 12.5%), migration (n = 3, 18.8%), sac expansion without endoleak (n = 2, 12.5%), graft infection (n = 3, 18.8%), rupture (n = 2, 12.5%). Nine patients (56.2%) underwent stent graft explantation with in situ surgical graft reconstruction, seven had endograft preserving open surgical intervention. The 30 day mortality was 18.8% (n = 3, all of whom having had endograft preservation). Ten patients (62.5%) suffered major in hospital complications. One patient (6.5%) required post-conversion major surgical re-intervention. IFU adherence during initial EVAR was 43.8%, versus 79.0% (p Open surgical conversion following EVAR results in significant morbidity and mortality. IFU adherence of EVARs later requiring open surgical

  17. Endovascular abdominal aortic repair for AAA. Anatomical suitability and limitation in Japanese population according to the inclusion criteria of Zenith AAA stent graft

    International Nuclear Information System (INIS)

    Kitagawa, Atsushi; Okita, Yutaka; Okada, Kenji

    2009-01-01

    Since 2007, the EVAR (endovascular abdominal aortic repair) grafts, Zenith, Excluder and Powerlink had been commercially available in Japan. However, a small iliac artery, typical of Japanese population especially in women, was a limiting factor to indicate EVAR. We analyzed the suitability of EVAR in Japanese population according to the inclusion criteria of Zenith AAA stent graft in the current study. From January 2006 to December 2007, 106 AAA (abdominal aortic aneurysm) patients (88 men, 18 women) with a mean age of 73 years were investigated in our institution by multi-slice CT scan in terms of suitability of EVAR, then we measured their abdominal aorta and iliac artery parameters as follows; proximal neck diameter (PND) and length (PNL), common iliac artery diameter (CIAD) and length (CIAL), suprarenal (SNA) and infrarenal neck angulation (INA), external iliac artery diameter (EIAD) and aortic length from the lowest renal artery to the aortic bifurcation (AOL). The inclusion criteria for Zenith AAA stent graft treatment were; PND: 18-28 mm, PNL more than 15 mm, unilateral CIAD less than 20 mm, CIAL at least 10 mm, SNA less than 45 degree and INA less than 60 degree, unilateral EIAD more than 7.5 mm. The indication of EVAR was 25.5% (27/106 patients), and was especially very low in women (5.6%) strictly according to the inclusion criteria of the Zenith AAA stent graft. The main reason of exclusion of EVAR was proximal short neck (40.5%), small iliac artery (30.4%) and infrarenal aortic neck angulation (29.1%). In our analysis, female AAA patients had small PNL and EIAD with angulated neck compared with male AAA ones. Anatomical suitability of EVAR in Japanese population strictly following by the inclusion criteria of Zenith AAA stent graft was low due to their characteristic differences from the European Union (EU) and the United States (US) patients, such as short proximal neck, steep neck angulation and small iliac artery, especially in women. More flexible

  18. Volumetric analysis demonstrates that true and false lumen remodeling persists for 12 months after thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Ga-Young Suh, PhD

    2016-09-01

    Full Text Available A 62-year-old man underwent an elephant trunk procedure followed by thoracic endovascular aortic repair (TEVAR. Computed tomography angiography-based models were built to quantify volume of the whole aorta and true and false lumens preoperatively, before TEVAR, after TEVAR, and at follow-up at 3, 6, and 12 months. With TEVAR, descending aortic true lumen volume increased by 54%, then increased additionally by 60% during 12 months. The descending aortic false lumen volume regressed continuously for 12 months following TEVAR, with the most rapid rate from 6 to 12 months at 16 cm3/month. TEVAR immediately increased true lumen volume and continued to remodel the true and false lumens throughout the following 12 months.

  19. Lumbar disc excision through fenestration

    Directory of Open Access Journals (Sweden)

    Sangwan S

    2006-01-01

    Full Text Available Background : Lumbar disc herniation often causes sciatica. Many different techniques have been advocated with the aim of least possible damage to other structures while dealing with prolapsed disc surgically in the properly selected and indicated cases. Methods : Twenty six patients with clinical symptoms and signs of prolapsed lumbar intervertebral disc having radiological correlation by MRI study were subjected to disc excision by interlaminar fenestration method. Results : The assessment at follow-up showed excellent results in 17 patients, good in 6 patients, fair in 2 patients and poor in 1 patient. The mean preoperative and postoperative Visual Analogue Scores were 9.34 ±0.84 and 2.19 ±0.84 on scale of 0-10 respectively. These were statistically significant (p value< 0.001, paired t test. No significant complications were recorded. Conclusion : Procedures of interlaminar fenestration and open disc excision under direct vision offers sufficient adequate exposure for lumbar disc excision with a smaller incision, lesser morbidity, shorter convalescence, early return to work and comparable overall results in the centers where recent laser and endoscopy facilities are not available.

  20. Risk models for mortality following elective open and endovascular abdominal aortic aneurysm repair: a single institution experience.

    Science.gov (United States)

    Choke, E; Lee, K; McCarthy, M; Nasim, A; Naylor, A R; Bown, M; Sayers, R

    2012-12-01

    To develop and validate an "in house" risk model for predicting perioperative mortality following elective AAA repair and to compare this with other models. Multivariate logistics regression analysis was used to identify risk factors for perioperative-day mortality from one tertiary institution's prospectively maintained database. Consecutive elective open (564) and endovascular (589) AAA repairs (2000-2010) were split randomly into development (810) and validation (343) data sets. The resultant model was compared to Glasgow Aneurysm Score (GAS), Modified Customised Probability Index (m-CPI), CPI, the Vascular Governance North West (VGNW) model and the Medicare model. Variables associated with perioperative mortality included: increasing age (P = 0.034), myocardial infarct within last 10 years (P = 0.0008), raised serum creatinine (P = 0.005) and open surgery (P = 0.0001). The areas under the receiver operating characteristic curve (AUC) for predicted probability of 30-day mortality in development and validation data sets were 0.79 and 0.82 respectively. AUCs for GAS, m-CPI and CPI were poor (0.63, 0.58 and 0.58 respectively), whilst VGNW and Medicare model were fair (0.73 and 0.79 respectively). In this study, an "in-house" developed and validated risk model has the most accurate discriminative value in predicting perioperative mortality after elective AAA repair. For purposes of comparative audit with case mix adjustments, national models such as the VGNW or Medicare models should be used. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Fate of patients with spinal cord ischemia complicating thoracic endovascular aortic repair.

    Science.gov (United States)

    DeSart, Kenneth; Scali, Salvatore T; Feezor, Robert J; Hong, Michael; Hess, Philip J; Beaver, Thomas M; Huber, Thomas S; Beck, Adam W

    2013-09-01

    Spinal cord ischemia (SCI) is a potentially devastating complication of thoracic endovascular aortic repair (TEVAR) that can result in varying degrees of short-term and permanent disability. This study was undertaken to describe the clinical outcomes, long-term functional impact, and influence on survival of SCI after TEVAR. A retrospective review of all TEVAR patients at the University of Florida from 2000 to 2011 was performed to identify individuals experiencing SCI, defined by any new lower extremity neurologic deficit not attributable to another cause. SCI was dichotomized into immediate or delayed onset, with immediate onset defined as SCI noted upon awakening from anesthesia, and delayed characterized as a period of normal function, followed by development of neurologic injury. Ambulatory status was determined using database query, record review, and phone interviews with patients and/or family. Mortality was estimated using life-table analysis. A total of 607 TEVARs were performed for various indications, with 57 patients (9.4%) noted to have postoperative SCI (4.3% permanent). SCI patients were more likely to be older (63.9 ± 15.6 vs 70.5 ± 11.2 years; P = .002) and have a number of comorbidities, including chronic obstructive pulmonary disease, hypertension, dyslipidemia, and cerebrovascular disease (P impact on postdischarge FI or long-term mortality. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  2. Immediate endovascular treatment of an aortoiliac aneurysm ruptured into the inferior vena cava.

    Science.gov (United States)

    Kopp, Reinhard; Weidenhagen, Rolf; Hoffmann, Ralf; Waggershauser, Tobias; Meimarakis, Georgios; Andrassy, Joachim; Clevert, Dirk; Czerner, Stephan; Jauch, Karl-Walter

    2006-07-01

    An aortocaval fistula is a severe complication of an aortoiliac aneurysm, usually associated with high perioperative morbidity and mortality during open operative repair. We describe the successful endovascular treatment of a symptomatic infrarenal aortic aneurysm ruptured into the inferior vena cava with secondary interventional coiling of a persistent type II endoleak because of retrograde perfusion of the inferior mesenteric artery. Endovascular exclusion of ruptured abdominal aneurysms seems to be a valuable treatment option for selected patients even with complicated vascular conditions like an aortocaval fistula.

  3. Endovascular Aortic Aneurysm Repair for Abdominal Aortic Aneurysm: Single Center Experience in 122 Patients

    International Nuclear Information System (INIS)

    Lee, Yun Young; Song, Jang Hyeon; Kim, Yong Tae; Yim, Nam Yeol; Kim, Jae Kyu; Lee, Ho Kyun; Choi, Soo Jin Na; Chung, Sang Young; Kim, Soo Hyun; Chang, Nam Kyu

    2013-01-01

    To analyze a single center experience of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms. Results of 122 patients who underwent EVAR were analyzed, retrospectively. Sex, age, aneurysmal morphology, hostile neck anatomy, preprocedural and postprocedural sac-diameter, technical and clinical success, postprocedural complication and need of additional procedure were analyzed. A total of 111 male and 11 female patients were included. Morphology of the aneurysms was as follows: fusiform (n = 108), saccular (n = 3) and ruptured type (n = 11). Sixty-four patients had hostile neck anatomy. The preprocedural mean sac-diameter was 52.4 mm. Postprocedural sac-diameter was decreased or stable in 110 patients (90.2%) and increased in 8 patients (6.6%). Technical success rate was 100% and clinical success rate was 86.1%. Fifty-one patients showed endoleak (41.8%) and 15 patients (12.3%) underwent secondary intervention due to type I endoleak (n = 4), type II endoleak (n = 4) and stent-graft thrombosis (n = 7). EVAR is a safe and effective therapy for abdominal aortic aneurysm, and it has high technical success and clinical success rate, and low complication rate.

  4. Morphological risk factors of stroke during thoracic endovascular aortic repair.

    Science.gov (United States)

    Kotelis, Drosos; Bischoff, Moritz S; Jobst, Bertram; von Tengg-Kobligk, Hendrik; Hinz, Ulf; Geisbüsch, Philipp; Böckler, Dittmar

    2012-12-01

    This study aims to identify independent factors correlating to an increased risk of perioperative stroke during thoracic endovascular aortic repair (TEVAR). A prospective maintained TEVAR database, medical records, and imaging studies of 300 patients (205 men; median age of all, 66 years, range 21-89), who underwent TEVAR between March 1997 and February 2011, were reviewed. Preoperative CT data sets were reviewed by two experienced radiologists with focus on the atheroma burden in the aortic arch (grade I, normal, to grade V, ulcerated or pedunculated atheroma). Aortic arch geometry (arch types I-III) was documented. Further parameters included in the univariate analysis were age, gender, urgency of repair, duration of procedure, adenosine-induced cardiac arrest or rapid pacing, proximal landing zone, left subclavian artery (LSA) coverage, and number of stent grafts. Multivariate logistic regression analysis was performed to assess the independent correlations of potential risk factors. Atherosclerotic aneurysm was the most common pathology (44%). One hundred and fifty-four of our patients (51%) were treated under urgent or emergent conditions. Seventeen percent of all patients had significant arch atheroma (grade IV or V), and 43% had a steep type III aortic arch. The perioperative stroke was 4% (12 patients; median age, 73 years, range 31-78). Two strokes were lethal (0.7%). All strokes were classified as embolic based on imaging characteristics. In eight patients, strokes were located in the left cerebral hemisphere (seven of them in the anterior and one in the posterior circulation). Four stroke patients (one in the left posterior circulation) underwent LSA coverage without revascularization. Three stroke patients had severe arch atheroma grade V. Five patients suffering stroke were recognized to have a type III aortic arch. Strokes were equally distributed between zones 0-2 vs. 3-4 (n = 6 each, 5 vs. 3.3%). The highest incidence was found in zone 1 (11

  5. Prevention of paraplegia after endovascular exclusion for stanford B thoracic aortic dissection aneurism

    International Nuclear Information System (INIS)

    Feng Rui; Jing Zaiping; Bao Junmin; Zhao Zhiqing; Zhao Jun; Feng Xiang; Lu Qingsheng; Huang Cheng

    2003-01-01

    Objective: To assess the prophylactic measures of paraplegia and paralysis after endovascular graft exclusion (EVE) for Stanford B thoracic aortic dissections (TAD). Methods: The records of 116 consecutive patients undergoing endovascular TAD repair from 1998 to 2001 were retrospectively reviewed. Steroids were administrated postoperatively in high risk patients likely to be candidates for paraplegia or paralysis. Results: No paraplegia or paralysis occurred postoperatively in all cases, including the patient undergone selective spinal artery angiography (SSAA). Conclusions: Transluminal repair can avoid spinal cord ischemia due to aortic cross-clamping, there is still a risk of spinal cord injury caused by occlusion of intercostal arteries under the cover of endograft. A combination of the prophylactic measures, including SSAA and steroids, have been able to reduce the risk of paraplegia and paralysis. A graft-stent of appropriate length is the key point of this procedure

  6. A novel technique combining laparoscopic and endovascular approaches using image fusion guidance for anterior embolization of type II endoleak

    Directory of Open Access Journals (Sweden)

    M. Mujeeb Zubair, MD

    2017-03-01

    Full Text Available Type II endoleak (T2E leading to aneurysm sac enlargement is one of the challenging complications associated with endovascular aneurysm repair. Recent guidelines recommend embolization of T2E associated with aneurysmal sac enlargement. Various percutaneous and endovascular techniques have been reported for embolization of T2E. We report a novel technique for T2E embolization combining laparoscopic and endovascular approaches using preoperative image fusion. We believe our technique provides a more direct access to the lumbar feeding vessels that is typically challenging with transarterial or translumbar embolization techniques.

  7. Laser Fenestration of Aortic Stent-Grafts Followed by Noncompliant vs Cutting Balloon Dilation: A Scanning Electron Microscopy Study.

    Science.gov (United States)

    Lin, Jing; Parikh, Niraj; Udgiri, Naval; Wang, Shaoxia; Miller, Daniel F; Li, Chaojing; Panneton, Jean; Nutley, Mark; Zhang, Ze; Huang, Yunfan; Lu, Jun; Zhang, Jingyi; Wang, Lu; Guidoin, Robert

    2018-06-01

    To examine the effects of in situ laser fenestration and subsequent balloon dilation (noncompliant vs cutting) on the graft fabric of 4 aortic stent-graft models. In an in vitro setup, the Zenith TX2, Talent, Endurant, and Anaconda aortic stent-grafts (all made of polyester graft material) were subjected to laser fenestration with a 2.3-mm-diameter probe at low and high energy in a physiologic saline solution followed by balloon dilation of the hole. For the first series of tests, 6-mm-diameter noncompliant balloons were used and replaced for the second series by 6-mm-diameter cutting balloons. Each procedure was performed 5 times (5 fenestrations per balloon type). The fenestrations were examined visually and with light and scanning electron microscopy. Each fenestration demonstrated various degrees of fraying and/or tearing regardless of the device. The monofilament twill weave of the Talent endograft tore in the warp direction up to 7.09±0.46 mm at high energy compared with 2.41±0.26 mm for the Endurant multifilament device. The fenestrations of the 3 endografts with multifilament weave (Zenith, Anaconda, and Endurant) showed more fraying; fenestration areas in the multifilament Endurant were >10 mm 2 at low and high energy. The fenestrations were free of melted fibers, but minor blackening of the filaments was observed in all devices. Overall, the cutting balloons resulted in worse tearing and damage. Of note, the edges of the dilated laser-formed fenestrations of the Talent and the Endurant grafts demonstrated evidence of additional shredded yarns. In situ fenestration does not cause any melting of the polyester; however, the observed structural damage to the fabric construction must be carefully considered. Cutting balloons caused various levels of tearing compared to the noncompliant balloons and cannot be recommended for use in this application. Rather, noncompliant balloons should be employed, but only with endografts constructed from multifilament yarns

  8. Patient Compliance with Surveillance Following Elective Endovascular Aneurysm Repair

    Energy Technology Data Exchange (ETDEWEB)

    Godfrey, Anthony D., E-mail: deangodfrey@yahoo.co.uk; Morbi, Abigail H. M., E-mail: a.morbi@soton.ac.uk; Nordon, Ian M., E-mail: ian.nordon@uhs.nhs.uk [University Hospital Southampton NHS Foundation Trust, Unit of Cardiac Vascular and Thoracic Surgery - CV& T, Department of Vascular Surgery (United Kingdom)

    2015-10-15

    PurposeIntegral to maintaining good outcomes post-endovascular aneurysm repair (EVAR) is a robust surveillance protocol. A significant proportion of patients fail to comply with surveillance, exposing themselves to complications. We examine EVAR surveillance in Wessex (UK), exploring factors that may predict poor compliance.MethodsRetrospective analysis of 179 consecutive elective EVAR cases [2008–2013] was performed. 167 patients were male, with the age range of 50–95. Surveillance was conducted centrally (tertiary referral trauma centre) and at four spoke units. Surveillance compliance and predictors of non-compliance including age, gender, co-morbid status, residential location and socioeconomic status were analysed for univariate significance.ResultsFifty patients (27.9 %) were non-compliant with surveillance; 14 (8.1 %) had no imaging post-EVAR. At 1 year, 56.1 % (of 123 patients) were compliant. At years 2 and 3, 41.5 and 41.2 % (of 65 and 34 patients, respectively) were compliant. Four years post-EVAR, only one of eight attended surveillance (12.5 %). There were no statistically significant differences in age (p = 0.77), co-morbid status or gender (p = 0.64). Distance to central unit (p = 0.67) and surveillance site (p = 0.56) was non-significant. While there was a trend towards compliance in upper-middle-class socioeconomic groups (ABC1 vs. C1C2D), correlating with >50 % of non-compliant patients living within <10 mile radius of the central unit, overall predictive value was not significant (p = 0.82).ConclusionsCompliance with surveillance post-EVAR is poor. No independent predictor of non-compliance has been confirmed, but socioeconomic status appears to be relevant. There is a worrying drop-off in attendance beyond the first year. This study highlights a problem that needs to be addressed urgently, if we are to maintain good outcomes post-EVAR.

  9. Patient Compliance with Surveillance Following Elective Endovascular Aneurysm Repair

    International Nuclear Information System (INIS)

    Godfrey, Anthony D.; Morbi, Abigail H. M.; Nordon, Ian M.

    2015-01-01

    PurposeIntegral to maintaining good outcomes post-endovascular aneurysm repair (EVAR) is a robust surveillance protocol. A significant proportion of patients fail to comply with surveillance, exposing themselves to complications. We examine EVAR surveillance in Wessex (UK), exploring factors that may predict poor compliance.MethodsRetrospective analysis of 179 consecutive elective EVAR cases [2008–2013] was performed. 167 patients were male, with the age range of 50–95. Surveillance was conducted centrally (tertiary referral trauma centre) and at four spoke units. Surveillance compliance and predictors of non-compliance including age, gender, co-morbid status, residential location and socioeconomic status were analysed for univariate significance.ResultsFifty patients (27.9 %) were non-compliant with surveillance; 14 (8.1 %) had no imaging post-EVAR. At 1 year, 56.1 % (of 123 patients) were compliant. At years 2 and 3, 41.5 and 41.2 % (of 65 and 34 patients, respectively) were compliant. Four years post-EVAR, only one of eight attended surveillance (12.5 %). There were no statistically significant differences in age (p = 0.77), co-morbid status or gender (p = 0.64). Distance to central unit (p = 0.67) and surveillance site (p = 0.56) was non-significant. While there was a trend towards compliance in upper-middle-class socioeconomic groups (ABC1 vs. C1C2D), correlating with >50 % of non-compliant patients living within <10 mile radius of the central unit, overall predictive value was not significant (p = 0.82).ConclusionsCompliance with surveillance post-EVAR is poor. No independent predictor of non-compliance has been confirmed, but socioeconomic status appears to be relevant. There is a worrying drop-off in attendance beyond the first year. This study highlights a problem that needs to be addressed urgently, if we are to maintain good outcomes post-EVAR

  10. Application of thoracic endovascular aortic repair (TEVAR) in treating dwarfism with Stanford B aortic dissection: A case report.

    Science.gov (United States)

    Qiu, Jian; Cai, Wenwu; Shu, Chang; Li, Ming; Xiong, Qinggen; Li, Quanming; Li, Xin

    2018-04-01

    To apply thoracic endovascular aortic repair (TEVAR) to treat dwarfism complicated with Stanford B aortic dissection. In this report, we presented a 63-year-old male patient of dwarfism complicated with Stanford B aortic dissection successfully treated with TEVAR. He was diagnosed with dwarfism complicated with Stanford B aortic dissection. After conservative treatment, the male patient underwent TEVAR at 1 week after hospitalization. After operation, he presented with numbness and weakness of his bilateral lower extremities, and these symptoms were significantly mitigated after effective treatment. At 1- and 3-week after TEVAR, the aorta status was maintained stable and restored. The patient obtained favorable clinical prognosis and was smoothly discharged. During subsequent follow-up, he remained physically stable. TEVAR is probably an option for treating dwarfism complicated with Stanford B aortic dissection, which remains to be validated by subsequent studies with larger sample size.

  11. Anterior petroclinoid fold fenestration: an adjunct to clipping of postero-laterally projecting posterior communicating aneurysms.

    Science.gov (United States)

    Nossek, Erez; Setton, Avi; Dehdashti, Amir R; Chalif, David J

    2014-10-01

    Proximally located posterior communicating artery (PCoA) aneurysms, projecting postero-laterally in proximity to the tentorium, may pose a technical challenge for microsurgical clipping due to obscuration of the proximal aneurysmal neck by the anterior petroclinoid fold. We describe an efficacious technique utilizing fenestration of the anterior petroclinoid fold to facilitate visualization and clipping of PCoA aneurysms abutting this aspect of the tentorium. Of 86 cases of PCoA aneurysms treated between 2003 and 2013, the technique was used in nine (10.5 %) patients to allow for adequate clipping. A 3 mm fenestration in the anterior petroclinoid ligament is created adjacent and lateral to the anterior clinoid process. This fenestration is then widened into a small wedge corridor by bipolar coagulation. In all cases, the proximal aneurysm neck was visualized after the wedge fenestration. Additionally, an adequate corridor for placement of the proximal clip blade was uniformly established. All cases were adequately clipped, with complete occlusion of the aneurysm neck and fundus with preservation of the PCoA. There were two intraoperative ruptures not related to creation of the wedge fenestration. One patient experienced post-operative partial third nerve palsy, which resolved during follow-up. We describe a technique of fenestration of the anterior petroclinoid fold to establish a critical and safe corridor for both visualization and clipping of PCoA aneurysms.

  12. Long-term decline in renal function is more significant after endovascular repair of infrarenal abdominal aortic aneurysms.

    Science.gov (United States)

    Al Adas, Ziad; Shepard, Alexander D; Nypaver, Timothy J; Weaver, Mitchell R; Maatman, Thomas; Yessayan, Lenar T; Balraj, Praveen; Kabbani, Loay S

    2018-03-20

    It is not clear whether endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs) results in an increase in renal insufficiency during the long term compared with open repair (OR). We reviewed our experience with AAA repair to determine whether there was a significant difference in postoperative and long-term renal outcomes between OR and EVAR. A retrospective cohort study was conducted of all patients who underwent AAA repair between January 1993 and July 2013 at a tertiary referral hospital. Demographics, comorbidities, preoperative and postoperative laboratory values, morbidity, and mortality were collected. Patients with ruptured AAAs, preoperative hemodialysis, juxtarenal or suprarenal aneurysm origin, and no follow-up laboratory values were excluded. Preoperative, postoperative, 6-month, and yearly serum creatinine values were collected. Glomerular filtration rate (GFR) was calculated on the basis of the Chronic Kidney Disease Epidemiology Collaboration equation. Acute kidney injury (AKI) was classified using the Kidney Disease: Improving Global Outcomes guidelines. Change in GFR was defined as preoperative GFR minus the GFR at each follow-up interval. Comparison was made between EVAR and OR groups using multivariate logistics for categorical data and linear regression for continuous variables. During the study period, 763 infrarenal AAA repairs were performed at our institution; 675 repairs fit the inclusion criteria (317 ORs and 358 EVARs). Mean age was 73.9 years. Seventy-nine percent were male, 78% were hypertensive, 18% were diabetic, and 31% had preoperative renal dysfunction defined as GFR below 60 mL/min. Using a multivariate logistic model to control for all variables, OR was found to have a 1.6 times greater chance for development of immediate postoperative AKI compared with EVAR (P = .038). Hypertension and aneurysm size were independent risk factors for development of AKI (P = .012 and .022, respectively). Using a linear

  13. Clinical and radiological instability following standard fenestration discectomy

    Directory of Open Access Journals (Sweden)

    Mascarenhas Amrithlal

    2009-01-01

    Full Text Available Background: Post-surgical lumbar instability is an established complication but there is limited evidence in the literature regarding the incidence of lumbar instability following fenestration and discectomy. We analyzed our results following fenestration discectomy with a special focus on instability. Materials and Methods: Eighty-three patients between the age of 17 and 52 years who had undergone fenestration discectomy for a single-level lumbar intervertebral disc prolapse were followed-up for a period of 1-5 years. The criteria for instability included "instability catch,", "painful catch," and "apprehension." The working capacity of the patient and the outcome score of the surgery were assessed by means of the Oswestry disability score and the Prolo economic and functional outcome score. Flexion-extension lateral radiographs were taken and analyzed for abnormal tilt and translation. Results: Of the 83 patients included, 70 were men and 13 were women, with an average age of 37.35 years (17-52 years at 5 years follow-up. Clinical instability was seen in 10 (12.04% patients. Radiological instability was noted in 29 (34.9% patients. Only six (60% of the 10 patients who demonstrated clinical instability had radiological evidence of instability. Twenty (68.96% patients with radiological instability were asymptomatic. Three (10.34% patients with only radiological instability had unsatisfactory outcome. The Oswestry scoring showed an average score of 19.8%. Mild disability was noted in 59 (71.08% patients and moderate disability was seen in 24 (28.91% patients. None of the patients had severe disability. These outcomes were compared with the outcomes in other studies in the literature for microdiscectomy and the results were found to be comparable. Conclusion: The favorable outcome of this study is in good agreement with other studies on microdiscectomy. Clinical instability in 12.04% of the patients is in agreement with other studies. Radiological

  14. Outcomes of Endovascular Abdominal Aortic Aneurysm Repair in Patients with Hostile Neck Anatomy

    International Nuclear Information System (INIS)

    Choke, Edward; Munneke, Graham; Morgan, Robert; Belli, Anna-Maria; Loftus, Ian; McFarland, Robert; Loosemore, Thomas; Thompson, Matthew M.

    2006-01-01

    Purpose. The principal anatomic contraindication to endovascular aneurysm repair (EVR) is an unfavorable proximal aortic neck. With increasing experience, a greater proportion of patients with unfavorable neck anatomy are being offered EVR. This study aimed to evaluate outcomes in patients with challenging proximal aortic neck anatomy. Methods. Prospectively collected data from 147 consecutive patients who underwent EVR between December 1997 and April 2005 were supplemented with a retrospective review of medical records and radiological images. Unfavorable anatomic features were defined as neck diameter >28 mm, angulation >60 deg., circumferential thrombus >50%, and length 30 days) (p = 0.57), distal type I endoleak (p = 0.40), type III endoleak (p 0.51), secondary interventions (p = 1.0), aneurysm sac expansion (p = 0.44), or 30 day mortality (p = 0.70). The good neck group had a significantly increased incidence of type II endoleak (p = 0.023). By multivariate analysis, the incidence of intraoperative adjunctive procedures was significantly increased in the presence of severe angulation (p = 0.041, OR 3.08, 95% CI 1.05-9.04). Conclusion. Patients with severely hostile proximal aortic neck anatomy may be treated with EVR, although severely angulated necks require additional intraoperative procedures. Early outcomes are encouraging and suggest that indications for EVR may be expanded to include patients with hostile neck anatomy

  15. Laparotomy during endovascular repair of ruptured abdominal aortic aneurysms increases mortality.

    Science.gov (United States)

    Adkar, Shaunak S; Turley, Ryan S; Benrashid, Ehsan; Cox, Mitchell W; Mureebe, Leila; Shortell, Cynthia K

    2017-02-01

    Subset analyses from small case series suggest patients requiring laparotomy during endovascular repair of ruptured abdominal aortic aneurysms (REVAR) have worse survival than those undergoing REVAR without laparotomy. Most concomitant laparotomies are performed for abdominal compartment syndrome. This study used data from the American College of Surgeons National Surgical Quality Improvement Program to determine whether the need for laparotomy during REVAR is associated with increased mortality. Data were obtained from the 2005 to 2013 National Surgical Quality Improvement Program participant user files based on Current Procedural Terminology (American Medical Association, Chicago, Ill) and International Classification of Diseases-9 Edition coding. Patient and procedure-related characteristics and 30-day postoperative outcomes were compared using Pearson χ 2 tests for categoric variables and Wilcoxon rank sum tests for continuous variables. A backward-stepwise multivariable logistic regression model was used to identify patient- and procedure-related factors associated with increased death after REVAR. We identified 1241 patients who underwent REVAR, and 91 (7.3%) required concomitant laparotomy. The 30-day mortality was 60% in the laparotomy group and 21% in the standard REVAR group (P < .001). The major complication rate was also higher in the laparotomy group (88% vs 63%; P < .001). Multivariable analysis showed laparotomy was strongly associated with 30-day mortality (odds ratio, 5.91; 95% confidence interval, 3.62-9.62; P < .001). Laparotomy during REVAR is a commonly used technique for the management of elevated intra-abdominal pressure and abdominal compartment syndrome development. The results of this study strongly confirm findings from smaller studies that the need for laparotomy during REVAR is associated with significantly worse 30-day survival. Copyright © 2016. Published by Elsevier Inc.

  16. Collected world and single center experience with endovascular treatment of ruptured abdominal aortic aneurysms.

    NARCIS (Netherlands)

    Veith, F.J.; Lachat, M.; Mayer, D.; Malina, M.; Holst, J.; Mehta, M.; Verhoeven, E.L.; Larzon, T.; Gennai, S.; Coppi, G.; Lipsitz, E.C.; Gargiulo, N.J.; Vliet, J.A. van der; Blankensteijn, J.D.; Buth, J.; Lee, W.A.; Biasiol, G.; Deleo, G.; Kasirajan, K.; Moore, R.; Soong, C.V.; Cayne, N.S.; Farber, M.A.; Raithel, D.; Greenberg, R.K.; Sambeek, M.R. van; Brunkwall, J.S.; Rockman, C.B.; Hinchliffe, R.J.

    2009-01-01

    BACKGROUND: Case and single center reports have documented the feasibility and suggested the effectiveness of endovascular aneurysm repair (EVAR) of ruptured abdominal aortic aneurysms (RAAAs), but the role and value of such treatment remain controversial. OBJECTIVE: To clarify these we examined a

  17. Collected World and Single Center Experience With Endovascular Treatment of Ruptured Abdominal Aortic Aneurysms

    NARCIS (Netherlands)

    Veith, Frank J.; Lachat, Mario; Mayer, Dieter; Malina, Martin; Holst, Jan; Mehta, Manish; Verhoeven, Eric L. G.; Larzon, Thomas; Gennai, Stefano; Coppi, Gioacchino; Lipsitz, Evan C.; Gargiulo, Nicholas J.; van der Vliet, J. Adam; Blankensteijn, Jan; Buth, Jacob; Lee, W. Anthony; Biasi, Giorgio; Deleo, Gaetano; Kasirajan, Karthikeshwar; Moore, Randy; Soong, Chee V.; Cayne, Neal S.; Farber, Mark A.; Raithel, Dieter; Greenberg, Roy K.; van Sambeek, Marc R. H. M.; Brunkwall, Jan S.; Rockman, Caron B.; Hinchliffe, Robert J.

    2009-01-01

    Background: Case and single center reports have documented the feasibility and suggested the effectiveness of endovascular aneurysm repair (EVAR) of ruptured abdominal aortic aneurysms (RAAAs), but the role and value of such treatment remain controversial. Objective: To clarify these we examined a

  18. Endovascular treatment of thoracic aorta aneurysm and dissection

    International Nuclear Information System (INIS)

    Petrov, I.; Stankov, Z.; Stefanov, St.; Stoyanov, Hr.

    2015-01-01

    Full text: The aim is to give up to date information about modern endovascular treatment of aortic pathology Dissection and aneurysms of the aorta are life threatening condition requiring in most of the cases prompt surgical or endovascular treatment because of the poor natural evolution. Purpose: to assess the immediate and 1-year outcome of endovascular treatment in broad spectrum of acute and subacute aortic syndrome during the last 3 years (November 2012 - August 2015) in City Clinic (Sofia, Bulgaria). We performed endovascular treatment of 47 patients (43 men, 4 women) at average age 54 y. with dissection (24) and aneurysms (23) of the aortic arch and thoracic aorta (in 5 emergent treatment was performed for aortic rupture). All patients were treated with minimal surgical femoral approach. In 4 (9%) of them initial carotid to carotid bypass was performed in order to provide a sufficient landing zone for the endograft implantation.the last 9 patients (19%) were treated without general anesthesia with either deep sedation or epidural anesthesia. Results: In all patients successful endograft implantation was achieved. Additional stent-graft or open cell stent was implanted in 4 cases in order to centralize the flow in the compressed true lumen. In 5 cases additional vascular plug or large coil was delivered in the left subclavian arteryostium in order to interrupt retrograde aneurysm or false lumen filling. Complications: 30 days mortality-2.2%, neurologic disorders (4.4%). one year survival- 45 (90.5%). 3 and 6 mo control CT scan showed no migration of the graft in 100%, full false lumen isolation in 19 out of 24 dissections (80%) and aneurysm free of expansion in 20 out of 23 (86%), patent carotid bay-pass graft in 4 of 4 (100%). This one center study showed excellent immediate and 1 year clinical and device results from endovascular repair of potentially fatal disease. Endovascular treatment is a method of choice for broad spectrum of aortic pathology

  19. Open surgery versus endovascular approach in treatment of extracranial carotid artery aneurysms.

    Science.gov (United States)

    Ni, Leng; Weng, Huiling; Pu, Zuo; Zheng, Yuehong; Liu, Bao; Ye, Wei; Zeng, Rong; Liu, Changwei

    2018-05-01

    The objective of this study was to investigate and to compare the early and long-term results of open surgery with endovascular intervention in the treatment of extracranial carotid artery aneurysms (ECCAs). A retrospective review of patients diagnosed with ECCAs who underwent open surgical or endovascular treatment from 1997 to 2017 was performed. Clinical characteristics, aneurysm profile, and treatment outcomes were recorded. Early results (open surgery; endovascular repair was performed on 16 patients (33.3%). The 30-day stroke or transient ischemic attack rate was not significantly different between the open group (6.3% [2/32]) and the endovascular group (0% [0/16]; P = .307). Cranial nerve injuries occurred in eight patients in the open group (25%) and in no patient in the endovascular group (0%; P = .029). Median length of stay was significantly longer in the open group than in the endovascular group (20 vs 14 days, respectively; P = .013). Median follow-up was 46 months (range, 0-20 years), and no aneurysm-related death occurred during this period. Overall survival rates at 5 years were 88.7% (standard error [SE], 0.08) in the open group and 91.7% (SE, 0.08) in the endovascular group (P = .319; log-rank, .992). For the same time interval, stroke-free survival rates were 85.2% (SE, 0.10) in the open group and 92.2% (SE, 0.07) in the endovascular group (P = .653; log-rank, .201). One patient (1/28 [3.6%]) in the open group and two patients (2/16 [12.5%]) in the endovascular group underwent endovascular reinterventions because of restenosis during the follow-up period. Reintervention-free survival rates were 90.9% in the open group (SE, 0.09) and 69.2% in the endovascular group (SE, 0.21; P = .082; log-rank, 3.016). In this single-institutional experience, both operative and endovascular interventions for ECCAs provided acceptable early and 5-year results. The endovascular approach had significantly less cranial nerve injury and shorter length of

  20. Fenestration system energy performance research, implementation, and international harmonization

    Energy Technology Data Exchange (ETDEWEB)

    McGowan, Raymond F [National Fenestration Rating Council, Greenbelt, MD (United States)

    2014-12-23

    The research conducted by the NFRC and its contractors adds significantly to the understanding of several areas of investigation. NFRC enables manufacturers to rate fenestration energy performance to comply with building energy codes, participate in ENERGY STAR, and compete fairly. NFRC continuously seeks to improve its ratings and also seeks to simplify the rating process. Several research projects investigated rating improvement potential such as • Complex Product VT Rating Research • Window 6 and Therm 6 Validation Research Project • Complex Product VT Rating Research Conclusions from these research projects led to important changes and increased confidence in the existing NFRC rating process. Conclusions from the Window 6/Therm 6 project will enable window manufacturers to rate an expanded array of products and improve existing ratings. Some research lead to an improved new rating method called the Component Modeling Approach. A primary goal of the CMA was a simplification of the commercial energy rating process to increase participation and make the commercial industry more competitive and code compliant. The project below contributed towards CMA development: • Component Modeling Approach Condensation Resistance Research NFRC continues to implement the Component Modeling Approach program. The program includes the CMA software tool, CMAST, and several procedural documents to govern the certification process. This significant accomplishment was a response the commercial fenestration industry’s need for a simplification of the present NFRC energy rating method (named site built). To date, most commercial fenestration is self-rated by a variety of techniques. The CMA enables commercial fenestration manufacturers to rate according to the NFRC 100/200 as most commercial energy codes require. International Harmonization NFRC achieved significant international harmonization success by continuing its licensing agreements with the Australian Fenestration

  1. Creating a Fontan fenestration in a child with dextrocardia and interrupted inferior vena cava

    Directory of Open Access Journals (Sweden)

    Pradeepkumar Charlagorla

    2016-01-01

    Full Text Available Plastic bronchitis is a rare life-threatening complication of the Fontan operation. Transcatheter Fontan fenestration can ameliorate symptoms by decompressing elevated venous pressures. Transcatheter creation of a fenestration can be technically challenging in cases with complex venous anatomy. We report a case of a 5-year-old boy with heterotaxy, dextrocardia with unbalanced atrioventricular canal (AVC, atrial and visceral situs inversus, left-sided superior vena cava (SVC, and left-sided interrupted inferior vena cava (IVC with azygos continuation. With few modifications to the equipment, a successful Fontan fenestration with stent implantation was performed via transjugular approach. At 2-year follow-up, his symptoms of plastic bronchitis improved significantly.

  2. Evaluation of Aneurysm Neck Angle Change After Endovascular Aneurysm Repair Clinical Investigations

    Energy Technology Data Exchange (ETDEWEB)

    Le, Trong Binh; Moon, Mi Hyoung [Inha University Hospital, Endovascular Training Center (Korea, Republic of); Jeon, Yong Sun, E-mail: radjeon@inha.ac.kr [Inha University Hospital, Inha University School of Medicine, Department of Radiology (Korea, Republic of); Hong, Kee Chun [Inha University School of Medicine, Department of Vascular Surgery (Korea, Republic of); Cho, Soon Gu [Inha University Hospital, Inha University School of Medicine, Department of Radiology (Korea, Republic of); Park, Keun-Myoung [Inha University School of Medicine, Department of Vascular Surgery (Korea, Republic of)

    2016-05-15

    PurposeTo evaluate the aneurysm neck angle changes and post-endovascular aneurysm repair (EVAR) complications.MethodsWe retrospectively analyzed 72 cases of elective EVAR for abdominal aortic aneurysm among 109 consecutive cases from December 2005 to April 2014. Patients were divided into angulated and non-angulated groups. The angulated group was defined as neck angulation ≥60°. Neck angle was evaluated pre- and post-EVAR during short- (within 1 month), mid- (3–6 months), and long-term (>1 year) follow-up. Aneurysm sac diameter change, aneurysm neck morphology other than angulation, endoleaks, and other post-procedural complications were also documented.ResultsA total of 34 patients were enrolled in the angulated group. There were no statistical differences in age, sex, follow-up duration, and aneurysm neck profile between the two groups (p > 0.05). Both groups showed statistically significant and consistent decreases in angulation during the follow-up period (p < 0.01). The angulated group revealed 22.45 % more straightening than the non-angulated group. Recoil of the Endurant device occurred in the angulated group. No statistically significant intergroup differences were observed in any endoleaks, complications, or re-intervention rates (p > 0.05). Pre-EVAR angle was the only predictor for post-procedural angle change (p < 0.001).ConclusionEVAR is applicable for patients with highly angulated aneurysm neck and provides consistent neck straightening over long-term follow-up. Recoil was evident in the angulated group using the Endurant device.

  3. Hybrid aortic repair with antegrade supra-aortic and renovisceral debranching from ascending aorta.

    Science.gov (United States)

    Del Castro-Madrazo, José Antonio; Rivas-Domínguez, Margarita; Fernández-Prendes, Carlota; Zanabili Al-Sibbai, Amer; Llaneza-Coto, José Manuel; Alonso-Pérez, Manuel

    2017-05-01

    Aortic dissection is a life threatening condition. Hybrid repair has been described for the treatment of complex aortic pathology such as thoracoabdominal aortic aneurysms (TAAA) and type A and B dissections, although open and total endovascular repair are also possible. Open surgery is still associated with substantial perioperative morbi-mortality rates, thus less invasive techniques such as endovascular repair and hybrid procedures can achieve good results in centers with experience. We present the case of a patient with a chronic type B dissection and TAAA degeneration that was treated in a single stage hybrid procedure with antegrade supra-aortic and renovisceral debranching from the ascending aorta and TEVAR. At three-year follow up, the patient is free of intervention-related complications.

  4. Endovascular treatment of three traumatic lesions of the vertebral artery

    International Nuclear Information System (INIS)

    Galvis, Victor Raul; Medina V, Francisco Jose

    2007-01-01

    The purpose is to expose the results of the endovascular treatment of three traumatic lesions of the vertebral artery. Methods: in the period from October 2005 to May 2006, three patients with traumatic lesions in the vertebral artery were treated by endovascular therapy with an age average of 32 years. All the procedures were carried out using subtraction digital angiography under anesthesiology supervision and were started with a 5,000 IU heparin bolus, previous antiplatelet medication with clopidogrel. For the treatment of the lesions covered stents and coils were used. results: there were three documented cases of traumatic lesions of the vertebral artery treated by endovascular therapy, in two cases arteriovenous fistulas were identified (between vertebral artery and internal jugular vein) with associated pseudo aneurysms, and in one case a pseudo aneurysm without fistula was found. The first patient was treated with placement of a covered stent, in a second patient the lesion was occluded with coils and a third patient required stent and coils with satisfactory repair of the lesions. Complications were not presented as a result of the procedures. Conclusions: the endovascular treatment for traumatic lesions of the vertebral artery is an alternative with minimum morbidity and reasonable costs avoiding the open surgery and conserving the permeability of the vessel when it is possible

  5. Is Internal Iliac Artery Embolization Essential Prior to Endovascular Repair of Aortoiliac Aneurysms?

    International Nuclear Information System (INIS)

    Bharwani, N.; Raja, J.; Choke, E.; Belli, A. M.; Thompson, M. M.; Morgan, R. A.; Munneke, G.

    2008-01-01

    Patients who undergo endovascular repair of aorto-iliac aneurysms (EVAR) require internal iliac artery (IIA) embolization (IIAE) to prevent type II endoleaks after extending the endografts into the external iliac artery. However, IIAE may not be possible in some patients due to technical factors or adverse anatomy. The aim of this study was to assess retrospectively whether patients with aorto-iliac aneurysms who fail IIAE have an increase in type II endoleak after EVAR compared with similar patients who undergo successful embolization. We retrospectively analyzed the records of 148 patients who underwent EVAR from December 1997 to June 2005. Sixty-one patients had aorto-iliac aneurysms which required IIAE before EVAR. Fifty patients had successful IIAE and 11 patients had unsuccessful IIAE prior to EVAR. The clinical and imaging follow-up was reviewed before and after EVAR. The endoleak rate of the embolized group was compared with that of the group in whom embolization failed. After a mean follow-up of 19.7 months in the study group and 25 months in the control group, there were no statistically significant differences in outcome measures between the two groups. Specifically, there were no type II endoleaks related to the IIA in patients where IIAE had failed. We conclude that failure to embolize the IIA prior to EVAR should not necessarily preclude patients from treatment. In patients where there is difficulty in achieving coil embolization, it is recommended that EVAR should proceed, as clinical sequelae are unlikely

  6. Tomografia computadorizada no diagnóstico da otosclerose fenestral

    Directory of Open Access Journals (Sweden)

    Vicente Andy de Oliveira

    2004-01-01

    Full Text Available OBJETIVO: Identificar os principais achados tomográficos da otosclerose fenestral e avaliar a utilidade da tomografia computadorizada de alta resolução (TCAR, como método diagnóstico dessa osteodistrofia. FORMA DE ESTUDO: Estudo prospectivo multicêntrico com tomografia computadorizada (TC de ossos temporais. MATERIAL E MÉTODO: 54 pacientes com diagnóstico clínico e cirúrgico de otosclerose. Foi realizada uma análise tomográfica, em que foi avaliada a sensibilidade da TC no diagnóstico radiológico da otosclerose fenestral, sendo verificados os principais sítios de lesões dessa doença, como também a sua bilateralidade e simetria. Foram incluídos neste estudo 22 pacientes submetidos à TC de ossos temporais para investigação de outras afecções otológicas, que constituíram o grupo controle. RESULTADOS: A TC foi positiva em 87% dos pacientes (77% das orelhas. Os achados tomográficos foram bilaterais na maioria dos casos (78,7%, e o foco fenestral mais prevalente foi o foco anterior à janela oval (FAJO. CONCLUSÕES: A TC apresentou um alto índice de positividade e o FAJO foi o foco mais prevalente nessa população, podendo ser considerado um achado tomográfico altamente sugestivo de otosclerose.

  7. Endovascular Aneurysm Repair of Acute Occlusion of Abdominal Aortic Aneurysm with Intra-Aneurysmal Dissection.

    Science.gov (United States)

    Terai, Yasuhiko; Mitsuoka, Hiroshi; Nakai, Masanao; Goto, Shinnosuke; Miyano, Yuta; Tsuchiya, Hirokazu; Yamazaki, Fumio

    2015-11-01

    To report a rare case of acute abdominal aortic aneurysm (AAA) occlusion successfully treated by endovascular aneurysm repair (EVAR). An 89-year-old man complained of severe back pain and weakness in the bilateral lower extremities. Although there were neither acute ischemic signs on the brain computed tomography (CT) nor critical leg ischemia, the patient presented progressing weakness in the bilateral lower extremities and decreased sensation in the perianal and saddle area. Contrast-enhanced CT demonstrated an infrarenal AAA, the formation of an ulcer-like lesion in the aneurysmal wall, and the complete occlusion of distal AAA because of the caudal extension of intramural hematoma. Both common iliac arteries were patent because of the development of collateral vessels. The neurologic symptoms were considered to be caused by the occlusion of lumbar radicular arteries. EVAR seemed anatomically feasible, if the occlusion could be crossed by guidewires from both side of the common femoral artery. Wires easily traversed the occlusion, and the stent graft could be smoothly unwrapped and opened. The patient could recover decent iliac arterial flow. The neurovascular deficits recovered within 4 days after the procedure. Although our experience may not be reproduced in all case of AAA occlusion, EVAR warrants consideration to reduce the high mortality rate associated with the classical treatments. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. The diaphragms of fenestrated endothelia: gatekeepers of vascular permeability and blood composition.

    Science.gov (United States)

    Stan, Radu V; Tse, Dan; Deharvengt, Sophie J; Smits, Nicole C; Xu, Yan; Luciano, Marcus R; McGarry, Caitlin L; Buitendijk, Maarten; Nemani, Krishnamurthy V; Elgueta, Raul; Kobayashi, Takashi; Shipman, Samantha L; Moodie, Karen L; Daghlian, Charles P; Ernst, Patricia A; Lee, Hong-Kee; Suriawinata, Arief A; Schned, Alan R; Longnecker, Daniel S; Fiering, Steven N; Noelle, Randolph J; Gimi, Barjor; Shworak, Nicholas W; Carrière, Catherine

    2012-12-11

    Fenestral and stomatal diaphragms are endothelial subcellular structures of unknown function that form on organelles implicated in vascular permeability: fenestrae, transendothelial channels, and caveolae. PV1 protein is required for diaphragm formation in vitro. Here, we report that deletion of the PV1-encoding Plvap gene in mice results in the absence of diaphragms and decreased survival. Loss of diaphragms did not affect the fenestrae and transendothelial channels formation but disrupted the barrier function of fenestrated capillaries, causing a major leak of plasma proteins. This disruption results in early death of animals due to severe noninflammatory protein-losing enteropathy. Deletion of PV1 in endothelium, but not in the hematopoietic compartment, recapitulates the phenotype of global PV1 deletion, whereas endothelial reconstitution of PV1 rescues the phenotype. Taken together, these data provide genetic evidence for the critical role of the diaphragms in fenestrated capillaries in the maintenance of blood composition. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. The Preclose Technique in Percutaneous Endovascular Aortic Repair: A Systematic Literature Review and Meta-analysis

    International Nuclear Information System (INIS)

    Jaffan, Abdel Aziz A.; Prince, Ethan A.; Hampson, Christopher O.; Murphy, Timothy P.

    2013-01-01

    Purpose. To establish the efficacy and safety of the preclose technique in total percutaneous endovascular aortic repair (PEVAR).MethodsA systematic literature search of Medline database was conducted for series on PEVAR published between January 1999 and January 2012.ResultsThirty-six articles comprising 2,257 patients and 3,606 arterial accesses were included. Anatomical criteria used to exclude patients from undergoing PEVAR were not uniform across all series. The technical success rate was 94 % per arterial access. Failure was unilateral in the majority (93 %) of the 133 failed PEVAR cases. The groin complication rate in PEVAR was 3.6 %; a minority (1.6 %) of these groin complications required open surgery. The groin complication rate in failed PEVAR cases converted to groin cutdown was 6.1 %. A significantly higher technical success rate was achieved when arterial access was performed via ultrasound guidance. Technical failure rate was significantly higher with larger sheath size (≥20F). Conclusion. The preclose technique in PEVAR has a high technical success rate and a low groin complication rate. Technical success tends to increase with ultrasound-guided arterial access and decrease with larger access. When failure occurs, it is unilateral in the majority of cases, and conversion to surgical cutdown does not appear to increase the operative risk.

  10. AngioVac Aspiration for Paradoxical Emboli Protection through a Fenestrated Fontan During Central Venous Thrombus Manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Al-Hakim, Ramsey, E-mail: ralhakim@mednet.ucla.edu [University of California, Department of Radiology, Division of Interventional Radiology (United States); Patel, Komal, E-mail: kdpatel@mednet.ucla.edu [University of California, Department of Anesthesiology, Division of Cardiothoracic Anesthesiology (United States); Moriarty, John M., E-mail: jmoriarty@mednet.ucla.edu [University of California, Department of Radiology, Division of Interventional Radiology (United States)

    2015-06-15

    This case reports describes a 39-year-old female with a history of surgically repaired hypoplastic left heart syndrome who presented with a left peripherally inserted central catheter (PICC) with associated large volume subclavian and brachiocephalic vein thrombus. Due to the presence of a right-to-left shunt via a fenestrated Fontan, there was clinical concern for a paradoxical embolism during removal of the PICC. The AngioVac aspiration system was successfully utilized to aspirate thromboemboli from the level of the proximal Glenn shunt during manipulation and removal of the PICC. This is the first reported case to demonstrate the safe and effective use of the AngioVac aspiration system for protection of paradoxical emboli through a cardiac right-to-left shunt during a procedure at high risk for thromboembolism.

  11. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    Thoracic endovascular aortic repair (TEVAR) has emerged as a promising therapeutic alternative to conventional open aortic replacement but it requires suitable proximal and distal landing zones for stent-graft anchoring. Many aortic pathologies affect in the immediate proximity of the left subcla...

  12. Perioperative risk factors for hospital readmission after elective endovascular aortic aneurysm repair.

    Science.gov (United States)

    Chen, Samuel L; Kuo, Isabella J; Kabutey, Nii-Kabu; Gabra, Fady; Fujitani, Roy M

    2018-04-02

    Elective endovascular aneurysm repair (EVAR) is generally well tolerated. However, the incidence of hospital readmission after EVAR and the risk factors and reasons for it are not well studied. This study sought to determine the incidence, to characterize the indications, and to identify perioperative patient-centered risk factors for hospital readmission within 30 days after elective EVAR. All patients who underwent EVAR electively in 2012 to 2013 were identified from the American College of Surgeons National Surgical Quality Improvement Program Targeted Vascular database (n = 3886). Preoperative demographics, operation-specific variables, and postoperative outcomes were compared between those who were readmitted within 30 days of the index operation and those who were not. Multivariate logistic regression was then used to determine independent predictors of hospital readmission. The unadjusted 30-day readmission rate after EVAR was 8.2%. Of all readmissions, 55% were for reasons related to the procedure. Median time to readmission was 12 days. Significant preoperative risk factors associated with readmission were female sex, preoperative steroid use, congestive heart failure, and dialysis dependence (P readmission, including myocardial infarction and deep venous thrombosis (P readmission were surgical site infection (odds ratio, 10.24; 95% confidence interval, 5.31-19.75; P readmissions remain a costly problem after vascular surgery and are associated with 30-day mortality after elective EVAR. Whereas female sex and certain irreversible medical comorbidities are nonmodifiable, focusing on medical optimization and identifying those perioperative variables that can affect the need for post-EVAR interventions will be an important step in decreasing hospital readmission. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  13. Ultrasound surveillance of endovascular aneurysm repair: a safe modality versus computed tomography.

    Science.gov (United States)

    Collins, John T; Boros, Michael J; Combs, Kristin

    2007-11-01

    Routine ultrasound surveillance is adequate and safe for monitoring endovascular aneurysm repairs (EVARs). A retrospective chart review including 160 endograft patients was performed from August 2000 to September 2005. All ultrasound examinations (n = 359) were performed by a board-certified vascular surgery group's accredited laboratory. Registered vascular technologists utilized the same equipment consisting of Siemens Antares high-definition ultrasonography with tissue harmonics and color flow Doppler. An identical protocol was followed by each technologist: scan body and both limbs of the endograft and distal iliac vessels, measure anterior-posterior aneurysm sac size, and detect intrasac pulsatility and color flow. Statistical analysis utilized Pearson's correlation coefficient and the paired t-test. Forty-one endoleaks were discovered out of the 359 exams (11.4%). There were type I (7, 17%), type II (26, 63%), and combined type I with type II (8, 20%) endoleaks. Correlation with computed tomography (CT) was obtained in 35 of these cases. CT discovered three endoleaks that were not seen with ultrasound. However, these particular ultrasound exams were inadequate due to additional factors (bowel gas, body habitus, hernia), which prompted CT investigation and, hence, endoleak discovery. Of the 41 endoleaks found on ultrasound, only 14 were seen on CT. Specifically, 26 type II endoleaks were seen with ultrasound versus only nine during CT. Additional factors addressed included comparison between ultrasound and CT of residual aneurysm sac measurements and conditions limiting ultrasound examination. Although criticized in the past, color flow ultrasonography is a safe and effective modality for surveillance of aortic endografts. Utilizing ultrasound to analyze abdominal aortic aneurysm (AAA) sac dimensions and endoleak detection is statistically sound for screening AAA status post-EVAR.

  14. [Therapeutic effect of insulin-like growth factor-1 injection into the inner ears through scala tympani fenestration on gentamicin-induced hearing loss in guinea pigs].

    Science.gov (United States)

    Li, Yong-he; Chen, Hao; Guo, Meng-he

    2008-02-01

    To study the therapeutic effect of insulin-like growth factor-1 (IGF-1) injection into the inner ears through a scala tympani fenestration on sensorineural deafness in a guinea pig model of gentamicin-induced hearing loss. Twenty guinea pigs with gentamicin-induced hearing loss were randomized equally into IGF-1 group and control group. In both groups, scala tympani fenestration was performed for injection of IGF-1 (10 microl) or artificial perilymphatic fluid (10 microl). Auditory brainstem responses (ABR) test was performed before and 7 and 14 days after surgery, respectively, and the cochlea was removed by decollation of 3 guinea pigs from each group after ABR test for observing the changes in the hair cells using scanning electron microscope. Significant reduction in the ABR response threshold (RT) occurred in IGF-1 group 7 and 14 days after the surgery, and on day 14, ABR RT showed significant difference between IGF-1 group and the control group. Scanning electron microscopy revealed severer damages of the hair cells in the control group, and in the IGF-1 group, finger-like microvilli was detected on the surface of the damaged hair cells. IGF-1 injection in the inner ear through the scala tympani fenestration may ameliorate the damages of the auditory function and relieve sustained toxicity of gentamicin in guinea pigs possibly by protection and partial repair of the damaged cochlea hair cells as well as protection of the afferent nerves.

  15. Use of platelet rich fibrin in a fenestration defect around an implant

    Directory of Open Access Journals (Sweden)

    R Vijayalakshmi

    2012-01-01

    Full Text Available Guided bone regeneration (GBR in implant therapy is especially useful for implant placement with dehiscence defects or fenestration defects. In alveolar ridges with marked facial/buccal depressions or in knifeedge alveolar crests, the position and direction of fixture placement is restricted. Improvement of alveolar ridge morphology becomes possible with GBR. This article describes a case in which the fenestration defect around an implant was treated by the application of platelet rich fibrin, a second generation platelet concentrate along with bone graft, and guided tissue regeneration membrane.

  16. Mid-term outcomes of endovascular aortic aneurysm repair with carbon dioxide-guided angiography.

    Science.gov (United States)

    Takeuchi, Yuriko; Morikage, Noriyasu; Matsuno, Yutaro; Nakamura, Tamami; Samura, Makoto; Ueda, Koshiro; Harada, Takasuke; Ikeda, Yoshitaka; Suehiro, Kotaro; Ito, Hiroshi; Sakata, Kensuke; Hamano, Kimikazu

    2018-05-14

    Although iodinated contrast (IC) agents are commonly used in endovascular aneurysm repair (EVAR), perioperative use in patients with renal dysfunction or IC allergies is avoided. Carbon dioxide (CO 2 )-guided angiography is a promising alternative. We aimed to evaluate short-term and mid-term outcomes of EVAR using CO 2 -guided angiography. Three hundred and eighty-one patients who underwent EVAR from January 2012 to September 2016 were retrospectively reviewed and divided into an IC-EVAR group (n=351) and CO 2 -EVAR group (n=30). Subjects in the CO 2 -EVAR group had severe renal dysfunction (n=27) and IC allergy (n=4). Intraoperative, postoperative, and follow-up variables were compared. Compared to the IC-EVAR group, preoperative serum creatinine level was significantly higher (2.0 vs. 0.92 mg/dL, P < .0001) and mean IC dose significantly lower (18 vs. 55 mL P < .0001) in the CO 2 -EVAR group. The fluoroscopy time, operative time, number of stent grafts placed, and technical success rates of the groups were similar; no type I and/or type III endoleaks were detected on completion angiography. There was no acute kidney injury and one case of intestinal necrosis in the CO 2 -EVAR group, potentially due to cholesterol embolism. Postoperative endoleak, enlargement of aneurysms, survival, freedom from secondary intervention, and renal function change up to 3 months postoperatively were similar between groups. CO 2 -EVAR is technically feasible and exhibits prominent renal protection. However, consideration of the aortic lumen status remains an important challenge. Copyright © 2018. Published by Elsevier Inc.

  17. Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Pierre Galvagni Silveira

    2008-01-01

    Full Text Available PURPOSE: To establish a correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter placed in the same aneurysm sac before and after its exclusion by an endoprosthesis. METHODS: Patients who underwent endovascular abdominal aortic aneurysm repair and received an EndoSureTM wireless pressure sensor implant between March 19 and December 11, 2004 were enrolled in the study. Simultaneous readings of systolic, diastolic, mean, and pulse pressure within the aneurysm sac were obtained from the catheter and the sensor, both before and after sac exclusion by the endoprosthesis (Readings 1 and 2, respectively. Intrasac pressure measurements were compared using Pearson's correlation and Student's t test. Statistical significance was set at p0.05, mean (p>0.05, and pulse (p0.05 by the sensor. CONCLUSION: The excellent agreement between intrasac pressure readings recorded by the catheter and the sensor justifies use of the latter for detection of post-exclusion abdominal aortic aneurysm pressurization.

  18. Fenestration of axillary vein by a variant axillary artery.

    Science.gov (United States)

    Hadimani, S; Desai, S D; Bagoji, I B; Patil, B S

    2013-01-01

    Variations of venous pattern in the arm are common. In this case report, we present a variation of axillary artery and vein. During routine educational dissections of axillary region, it was observed that a fenestrated axillary vein was perforated by a variant axillary artery in right arm of an old male cadaver. The axillary artery which was fenestrated through axillary vein had only two branches arising from its second part and no branches from its remaining distal parts. The branches are thoraco-acromial (usual) and another large collateral (unusual) branch. This collateral branch is the origin of several important arteries as the subscapular, circumflex scapular, posterior circumflex humeral and lateral thoracic arteries. We propose to name this artery as collateral axillary arterial trunk. The course of this collateral axillary arterial trunk and its branches and also clinical significance of this variation are discussed in the paper.

  19. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp; Yamasaki, Motoshige, E-mail: genyamasaki@gmail.com [Kawasaki Saiwai Hospital, Department of Interventional Radiology (Japan)

    2015-04-15

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasation of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.

  20. Endovascular aneurysm repair simulation can lead to decreased fluoroscopy time and accurately delineate the proximal seal zone.

    Science.gov (United States)

    Kim, Ann H; Kendrick, Daniel E; Moorehead, Pamela A; Nagavalli, Anil; Miller, Claire P; Liu, Nathaniel T; Wang, John C; Kashyap, Vikram S

    2016-07-01

    The use of simulators for endovascular aneurysm repair (EVAR) is not widespread. We examined whether simulation could improve procedural variables, including operative time and optimizing proximal seal. For the latter, we compared suprarenal vs infrarenal fixation endografts, right femoral vs left femoral main body access, and increasing angulation of the proximal aortic neck. Computed tomography angiography was obtained from 18 patients who underwent EVAR at a single institution. Patient cases were uploaded to the ANGIO Mentor endovascular simulator (Simbionix, Cleveland, Ohio) allowing for three-dimensional reconstruction and adapted for simulation with suprarenal fixation (Endurant II; Medtronic Inc, Minneapolis, Minn) and infrarenal fixation (C3; W. L. Gore & Associates Inc, Newark, Del) deployment systems. Three EVAR novices and three experienced surgeons performed 18 cases from each side with each device in randomized order (n = 72 simulations/participant). The cases were stratified into three groups according to the degree of infrarenal angulation: 0° to 20°, 21° to 40°, and 41° to 66°. Statistical analysis used paired t-test and one-way analysis of variance. Mean fluoroscopy time for participants decreased by 48.6% (P time decreased by 33.8% (P zone coverage in highly angulated aortic necks was significantly decreased. The infrarenal device resulted in mean aortic neck zone coverage of 91.9%, 89.4%, and 75.4% (P zone coverage. The side of femoral access for the main body did not influence proximal seal zone coverage regardless of infrarenal angulation. Simulation of EVAR leads to decreased fluoroscopy times for novice and experienced operators. Side of femoral access did not affect precision of proximal endograft landing. The angulated aortic neck leads to decreased proximal seal zone coverage regardless of infrarenal or suprarenal fixation devices. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  1. Fenestrations and Various Duplications of the Posterior Communicating Artery in the Prenatal and Postnatal Periods.

    Science.gov (United States)

    Trandafilović, Milena; Vasović, Ljiljana; Vlajković, Slobodan; Đorđević, Gordana; Stojanović, Borisav; Mladenović, Marija

    2016-07-01

    The 2 paired arteries-the posterior communicating arteries (PCoAs) and the precommunicating parts of the posterior cerebral arteries-form the so-called posterior segment of the cerebral arterial circle on the base of the brain. A number of (ab)normal morphologic features were described in the literature (e.g., unusual kinking, or extreme elongations, hypoplasia, duplications, fenestrations, the infundibular widening, or aplasia of the PCoA in the prenatal and/or postnatal periods). The aim of this study was to analyze an incidence of various fenestrations and duplications of the PCoA, and describe their general features and their association with other vascular abnormalities. The research was performed on the brains of 200 human fetuses and 377 adult cadavers of both genders and different ages using microdissection and macrodissection methods. There were 0.34% cases with PCoA fenestrations and 3.12% cases with various PCoA duplications. Their morphologic features were described and compared with the similar PCoA abnormalities recorded in the scientific literature. There was no association between the PCoA and either duplication or aneurysm in adult cases. After thorough examination, the fenestrations and duplications of the PCoA are distinguished as 2 special forms of vascular abnormalities, and the PCoA duplications are characterized as partial and total. Furthermore, whereas the low incidence of a fenestration of the PCoA suggests it to be a sufficiently rare phenomenon, the duplications of the PCoA trunk are fairly frequent, especially concerning its terminal segment. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Life satisfaction in patients with and without spinal cord ischemia after advanced endovascular therapy for extensive aortic disease at mid-term follow-up.

    Science.gov (United States)

    Mehmedagic, Irma; Santén, Stefan; Jörgensen, Sophie; Acosta, Stefan

    2016-11-11

    Advanced endovascular aortic repair can be used to treat patients with extensive and complex aortic disease who are at risk of spinal cord ischaemia. The aim of this study was to compare whether life satisfaction differs between patients with and without spinal cord ischaemia at mid-term follow-up. Nested case-control study. Among patients undergoing advanced endovascular aortic repair between 2009 and 2012, 18 patients with spinal cord ischaemia and 33 without were interviewed at home. The Life Satisfaction Questionnaire (LiSat-11) and the Satisfaction With Life Scale (SWLS) were used. LiSat-11 found that patients with spinal cord ischaemia were more dissatisfied with their activities of daily living than were patients without spinal cord ischaemia (p=0.012). Both groups had similar, very low, scores in the sexual life domain; median 2.0 (interquartile range (IQR) 1.5-3.0) and 3.0 (IQR 2.0-4.0), respectively. There was no difference in SWLS between the groups. This study cohort of patients who underwent advanced endovascular aortic repair was rather homo-genous in their rating of life satisfaction and there was little difference between mid-term survivors who had spinal cord ischaemia and those who did not.

  3. The financial implications of endovascular aneurysm repair in the cost containment era.

    Science.gov (United States)

    Stone, David H; Horvath, Alexander J; Goodney, Philip P; Rzucidlo, Eva M; Nolan, Brian W; Walsh, Daniel B; Zwolak, Robert M; Powell, Richard J

    2014-02-01

    Endovascular aneurysm repair (EVAR) is associated with significant direct device costs. Such costs place EVAR at odds with efforts to constrain healthcare expenditures. This study examines the procedure-associated costs and operating margins associated with EVAR at a tertiary care academic medical center. All infrarenal EVARs performed from April 2011 to March 2012 were identified (n = 127). Among this cohort, 49 patients met standard commercial instruction for use guidelines, were treated using a single manufacturer device, and billed to Medicare diagnosis-related group (DRG) 238. Of these 49 patients, net technical operating margins (technical revenue minus technical cost) were calculated in conjunction with the hospital finance department. EVAR implant costs were determined for each procedure. DRG 238-associated costs and length of stay were benchmarked against other academic medical centers using University Health System Consortium 2012 data. Among the studied EVAR cohort (age 75, 82% male, mean length of stay, 1.7 days), mean technical costs totaled $31,672. Graft implants accounted for 52% of the allocated technical costs. Institutional overhead was 17% ($5495) of total technical costs. Net mean total technical EVAR-associated operating margins were -$4015 per procedure. Our institutional costs and length of stay, when benchmarked against comparable centers, remained in the lowest quartile nationally using University Health System Consortium costs for DRG 238. Stent graft price did not correlate with total EVAR market share. EVAR is currently associated with significant negative operating margins among Medicare beneficiaries. Currently, device costs account for over 50% of EVAR-associated technical costs and did not impact EVAR market share, reflecting an unawareness of cost differential among surgeons. These data indicate that EVAR must undergo dramatic care delivery redesign for this practice to remain sustainable. Copyright © 2014 Society for Vascular

  4. Endovascular aneurysm repair delivery redesign leads to quality improvement and cost reduction.

    Science.gov (United States)

    Warner, Courtney J; Horvath, Alexander J; Powell, Richard J; Columbo, Jesse A; Walsh, Teri R; Goodney, Philip P; Walsh, Daniel B; Stone, David H

    2015-08-01

    Endovascular aneurysm repair (EVAR) is now a mainstay of therapy for abdominal aortic aneurysm, although it remains associated with significant expense. We performed a comprehensive analysis of EVAR delivery at an academic medical center to identify targets for quality improvement and cost reduction in light of impending health care reform. All infrarenal EVARs performed from April 2011 to March 2012 were identified (N = 127). Procedures were included if they met standard commercial instructions for use guidelines, used a single manufacturer, and were billed to Medicare diagnosis-related group 238 (n = 49). By use of DMAIC (define, measure, analyze, improve, and control) quality improvement methodology (define, measure, analyze, improve, control), targets for EVAR quality improvement were identified and high-yield changes were implemented. Procedure technical costs were calculated before and after process redesign. Perioperative services and clinic visits were identified as targets for quality improvement efforts and cost reduction. Mean technical costs before the intervention were $31,672, with endograft implants accounting for 52%. Pricing redesign in collaboration with hospital purchasing reduced mean EVAR technical costs to $28,607, a 10% reduction in overall cost, with endograft implants now accounting for 46%. Perioperative implementation of instrument tray redesign reduced instrument use by 32% (184 vs 132 instruments), saving $50,000 annually. Unnecessary clinic visits were reduced by 39% (1.6 vs 1.1 clinic visits per patient) through implementation of a preclinic imaging protocol. There was no difference in mean length of stay after the intervention. Comprehensive EVAR delivery redesign leads to cost reduction and waste elimination while preserving quality. Future efforts to achieve more competitive and transparent device pricing will make EVAR more cost neutral and enhance its financial sustainability for health care systems. Copyright © 2015 Society for

  5. 3D printing of an aortic aneurysm to facilitate decision making and device selection for endovascular aneurysm repair in complex neck anatomy.

    Science.gov (United States)

    Tam, Matthew D B S; Laycock, Stephen D; Brown, James R I; Jakeways, Matthew

    2013-12-01

    To describe rapid prototyping or 3-dimensional (3D) printing of aneurysms with complex neck anatomy to facilitate endovascular aneurysm repair (EVAR). A 75-year-old man had a 6.6-cm infrarenal aortic aneurysm that appeared on computed tomographic angiography to have a sharp neck angulation of ~90°. However, although the computed tomography (CT) data were analyzed using centerline of flow, the true neck length and relations of the ostial origins were difficult to determine. No multidisciplinary consensus could be reached as to which stent-graft to use owing to these borderline features of the neck anatomy. Based on past experience with rapid prototyping technology, a decision was taken to print a model of the aneurysm to aid in visualization of the neck anatomy. The CT data were segmented, processed, and converted into a stereolithographic format representing the lumen as a 3D volume, from which a full-sized replica was printed within 24 hours. The model demonstrated that the neck was adequate for stent-graft repair using the Aorfix device. Rapid prototyping of aortic aneurysms is feasible and can aid decision making and device delivery. Further work is required to test the value of 3D replicas in planning procedures and their impact on procedure time, radiation dose, and procedure cost.

  6. Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

    International Nuclear Information System (INIS)

    Juszkat, Robert; Pukacki, Fryderyk; Zarzecka, Anna; Kulesza, Jerzy; Majewski, Waclaw

    2009-01-01

    We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The procedure was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.

  7. Endovascular repair or medical treatment of acute type B aortic dissection? A comparison

    Energy Technology Data Exchange (ETDEWEB)

    Chemelli-Steingruber, I. [Department of Radiology, Innsbruck Medical University (Austria); Chemelli, A. [Department of Radiology, Innsbruck Medical University (Austria)], E-mail: andreas.chemelli@i-med.ac.at; Strasak, A. [Department of Medical Statistics, Informatics and Health Economics, Innsbruck Medical University (Austria); Hugl, B. [Department of Vascular Surgery, Innsbruck Medical University (Austria); Hiemetzberger, R. [Department of Cardiology, Innsbruck Medical University (Austria); Jaschke, W.; Glodny, B.; Czermak, B.V. [Department of Radiology, Innsbruck Medical University (Austria)

    2010-01-15

    Introduction: The aim of this retrospective study was to compare the outcome of thoracic endovascular aortic repair (TEVAR) to that of medical therapy in patients with acute type B aortic dissection (TBD). Materials and methods: From July 1996 to April 2008, 88 patients presenting with acute TBD underwent either TEVAR (group A, n = 38) or medical therapy (group B, n = 50). Indications for TEVAR were intractable pain, aortic branch compromise resulting in end-organ ischemia, rapid aortic dilatation and rupture. Follow-up was performed postinterventionally, at 3, 6 and 12 months and yearly thereafter and included clinical examinations and computed tomography (CT), as well as aortic diameter measurements and assessment of thrombosis. Results: Mean follow-up was 33 months in group A and 36 months in group B. The overall mortality rate was 23.7% in group A and 24% in group B, where 4 patients died of late aortic rupture. In group A, complications included 9 endoleaks and 4 retrograde type A dissections, 3 patients were converted to open surgery and 2 needed secondary intervention. None of the patients developed paraplegia. In group B, 4 patients were converted to open surgery and 2 to TEVAR. The maximal aortic diameter increased in both groups. Regarding the extent of thrombosis, our analyses showed slightly better overall results after TEVAR, but they also showed a tendency towards approximation between the two groups during follow-up. Conclusion: TEVAR is a feasible treatment option in acute TBD. However, several serious complications may occur during and after TEVAR and it should therefore be reserved to patients with life-threatening symptoms.

  8. Endoscopic repair of an injured internal carotid artery utilizing femoral endovascular closure devices.

    Science.gov (United States)

    Van Rompaey, Jason; Bowers, Greg; Radhakrishnan, Jay; Panizza, Benedict; Solares, C Arturo

    2014-06-01

    Injury to the internal carotid artery is a feared complication of endoscopic endonasal surgery of the skull base. Such an event, although rare, is associated with high morbidity and mortality. Even if bleeding is controlled, permanent neurological defects frequently persist. Many techniques have been developed to manage internal carotid artery rupture with varying degrees of success. The purpose of this study was to explore endoscopic management of arterial damage with endovascular closure devices used for a femoral arteriotomy. The ability to remotely suture a damaged artery permits the possible adaptation of this technology in managing endoscopic arterial complications. Technical note. After the creation of an endoscopic endonasal corridor in a cadaveric specimen, an arteriotomy was created at the cavernous portion of the internal carotid artery. The Angio-Seal, StarClose, and MynxGrip vascular closure devices were utilized under endoscopic guidance to repair the arteriotomy. Angiography was then done on a cadaver sutured with the StarClose. Both the Angio-Seal and StarClose were deployed quickly and appeared to provide sufficient closure of the arteriotomy. The Angio-Seal required the use of a guidewire and was longer to deploy when compared with the StarClose. The StarClose deployment was quick and facile. The MynxGrip also deployed without difficulty. The Angio-Seal and StarClose systems were both successfully deployed utilizing an endoscopic endonasal approach. The MynxGrip was the easiest to deploy and has the greatest potential to be of benefit in this application. Further studies with hemodynamic models are required to properly assess the appropriateness in this setting. NA. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  9. Greater Trochanteric Pain Syndrome: Percutaneous Tendon Fenestration Versus Platelet-Rich Plasma Injection for Treatment of Gluteal Tendinosis.

    Science.gov (United States)

    Jacobson, Jon A; Yablon, Corrie M; Henning, P Troy; Kazmers, Irene S; Urquhart, Andrew; Hallstrom, Brian; Bedi, Asheesh; Parameswaran, Aishwarya

    2016-11-01

    The purpose of this study was to compare ultrasound-guided percutaneous tendon fenestration to platelet-rich plasma (PRP) injection for treatment of greater trochanteric pain syndrome. After Institutional Review Board approval was obtained, patients with symptoms of greater trochanteric pain syndrome and ultrasound findings of gluteal tendinosis or a partial tear (Pain scores were recorded at baseline, week 1, and week 2 after treatment. Retrospective clinic record review assessed patient symptoms. The study group consisted of 30 patients (24 female), of whom 50% were treated with fenestration and 50% were treated with PRP. The gluteus medius was treated in 73% and 67% in the fenestration and PRP groups, respectively. Tendinosis was present in all patients. In the fenestration group, mean pain scores were 32.4 at baseline, 16.8 at time point 1, and 15.2 at time point 2. In the PRP group, mean pain scores were 31.4 at baseline, 25.5 at time point 1, and 19.4 at time point 2. Retrospective follow-up showed significant pain score improvement from baseline to time points 1 and 2 (P.99). Our study shows that both ultrasound-guided tendon fenestration and PRP injection are effective for treatment of gluteal tendinosis, showing symptom improvement in both treatment groups. © 2016 by the American Institute of Ultrasound in Medicine.

  10. A novel method of creation of a fenestration in nitinol occluder devices used in closure of hypertensive patent arterial ducts

    Directory of Open Access Journals (Sweden)

    Anil Kumar Singhi

    2016-01-01

    Full Text Available Test occlusion with a balloon is done to predict operability of large hypertensive patent ductus arteriosus (PDA. If the fall in the pulmonary artery pressures is inadequate, a complete closure is not desired. To create a predictable premeasured fenestration in a nitinol occluder device used for closing hypertensive PDA. A large nitinol occluder device was punctured with an 18G needle to advance a 0.035½ stiff guide wire through the occluder before loading it into the delivery system. The occluder with the guidewire was then deployed across the PDA. A coronary guide catheter was later threaded through the guidewire into the fabric of the device, which was still held by the delivery cable. A coronary stent was deployed across the fenestration in the occluder to keep it patent. An 8-year-old boy with Down syndrome and hypertensive PDA was hemodynamically assessed. Even though there was a fall in the pulmonary vascular resistance index and pressures on test occlusion, the pulmonary artery pressures were labile with fluctuations. A customized fenestration was made in a 16 mm muscular ventricular septal defect occluder (MVSO with a 4.5 mm bare-metal coronary stent. The pulmonary artery pressures remained at half of the aortic pressures after the procedure. This fenestration model precisely and predictably fenestrated a large occluder device used to close a hypertensive large PDA. Long-term patency of these fenestrations has to be assessed on the follow-up, and may be improved through larger fenestrations, systemic anticoagulation and use of covered stents.

  11. Transhepatic approach for extracardiac inferior cavopulmonary connection stent fenestration.

    LENUS (Irish Health Repository)

    Kenny, Damien

    2012-02-01

    We report on a 3-year-old male who underwent transcatheter stent fenestration of the inferior portion of an extracardiac total cavopulmonary connection in the setting of hypoplastic left heart syndrome. Transhepatic approach, following an unsuccessful attempt from the femoral vein facilitated delivery of a diabolo-shaped stent.

  12. Contrast Medium Induced Nephropathy after Endovascular Stent Graft Placement: An Examination of Its Prevalence and Risk Factors

    International Nuclear Information System (INIS)

    Kawatani, Yohei; Nakamura, Yoshitsugu; Mochida, Yoshihiko; Yamauchi, Naoya; Hayashi, Yujiro; Taneichi, Tetsuyoshi; Ito, Yujiro; Kurobe, Hirotsugu; Suda, Yuji; Hori, Takaki

    2016-01-01

    Endovascular stent graft placement has become a major treatment for thoracic and abdominal aneurysms. While endovascular therapy is less invasive than open surgery, it involves the use of a contrast medium. Contrast media can cause renal impairment, a condition termed as contrast-induced nephropathy (CIN). This study sought to evaluate the incidence and risk factors of CIN following endovascular stent graft placement for aortic aneurysm repair. The study included 167 consecutive patients who underwent endovascular stent graft placement in our hospital from October 2013 to June 2014. CIN was diagnosed using the European Society of Urogenital Radiology criteria. Patients with and without CIN were compared. Chi-squared tests, t-tests, and multivariate logistic regression analyses were performed. Thirteen patients (7.8%) developed CIN. Left ventricular dysfunction and intraoperative blood transfusion were significantly more frequent in the CIN group (P = 0.017 and P = 0.032, resp.). Multivariate analysis showed that left ventricular dysfunction had the strongest influence on CIN development (odds ratio 9.34, P = 0.018, and 95% CI = 1.46–59.7). Patients with CIN also experienced longer ICU and hospital stays. Measures to improve renal perfusion flow should be considered for patients with left ventricular dysfunction who are undergoing endovascular stent graft placement

  13. Outcomes after open repair for ruptured abdominal aortic aneurysms in patients with friendly versus hostile aortoiliac anatomy

    NARCIS (Netherlands)

    van Beek, S. C.; Reimerink, J. J.; Vahl, A. C.; Wisselink, W.; Reekers, J. A.; Legemate, D. A.; Balm, R.

    2014-01-01

    In patients with a ruptured abdominal aortic aneurysm (RAAA), anatomic suitability for endovascular aneurysm repair (EVAR) depends on aortic neck and iliac artery characteristics. If the aortoiliac anatomy is unsuitable for EVAR ("hostile anatomy"), open repair (OR) is the next option. We

  14. Extreme fenestration of the basilar artery associated with cleft palate, nasopharyngeal mature teratoma, and hypophyseal duplication

    Energy Technology Data Exchange (ETDEWEB)

    Uchino, A.; Sawada, A.; Takase, Y.; Kudo, S. [Department of Radiology, Saga Medical School, 5-1-1, Nabeshima, Saga 849-8501 (Japan); Fujita, I. [Department of Pediatrics, Saga Medical School, 5-1-1, Nabeshima, Saga 849-8501 (Japan)

    2002-08-01

    The authors present the case of a newborn girl with extreme fenestration of the basilar artery. This anomaly was found incidentally during MR imaging study for cleft palate and nasopharyngeal teratoma. Magnetic resonance angiography showed a totally duplicated basilar artery with connections at the proximal and distal ends of the artery, suggesting an extreme fenestration. Duplicated pituitary gland was also found on MR imaging. (orig.)

  15. Extreme fenestration of the basilar artery associated with cleft palate, nasopharyngeal mature teratoma, and hypophyseal duplication

    International Nuclear Information System (INIS)

    Uchino, A.; Sawada, A.; Takase, Y.; Kudo, S.; Fujita, I.

    2002-01-01

    The authors present the case of a newborn girl with extreme fenestration of the basilar artery. This anomaly was found incidentally during MR imaging study for cleft palate and nasopharyngeal teratoma. Magnetic resonance angiography showed a totally duplicated basilar artery with connections at the proximal and distal ends of the artery, suggesting an extreme fenestration. Duplicated pituitary gland was also found on MR imaging. (orig.)

  16. Osteomyelitis and Discitis Following Translumbar Repair of a Type II Endoleak

    Energy Technology Data Exchange (ETDEWEB)

    Sella, David M., E-mail: Sella.david@mayo.edu; Frey, Gregory T., E-mail: Frey.gregory@mayo.edu; Giesbrandt, Kirk, E-mail: giesbrandt.kirk@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2016-03-15

    Here we present the case of an 80-year-old man who developed a type II endoleak following endovascular abdominal aortic aneurysm repair. Initial attempts at treating the endoleak via a transarterial approach were unsuccessful; therefore the patient underwent percutaneous translumbar endoleak embolization. Approximately 1 month following the translumbar procedure, he developed back pain, with subsequent workup revealing osteomyelitis and discitis as a complication following repair via the translumbar approach.

  17. Placement of endosseous implant in infected alveolar socket with large fenestration defect: A comparative case report

    Directory of Open Access Journals (Sweden)

    Balaji Anitha

    2010-01-01

    Full Text Available Placement of endosseous implants into infected bone is often deferred or avoided due to fear of failure. However, with the development of guided bone regeneration [GBR], some implantologists have reported successful implant placement in infected sockets, even those with fenestration defects. We had the opportunity to compare the osseointegration of an immediate implant placed in an infected site associated with a large buccal fenestration created by the removal of a root stump with that of a delayed implant placed 5 years after extraction. Both implants were placed in the same patient, in the same dental quadrant by the same implantologist. GBR was used with the fenestration defect being filled with demineralized bone graftFNx01 and covered with collagen membraneFNx08. Both implants were osseointegrated and functional when followed up after 12 months.

  18. Endovascular Treatment of an Aortoiliac Tuberculous Pseudoaneurysm

    International Nuclear Information System (INIS)

    Villegas, Miguel O.; Mereles, Alberto Pérez; Tamashiro, Gustavo A.; Dini, Andrés E.; Mollón, Ana P.; De Cándido, Laura V.; Zelaya, Denis A.; Soledispa-Suarez, Carlos I.; Denato, Sergio; Tamashiro, Alberto; Diaz, Jose A.

    2013-01-01

    We report a rare case of a tuberculous mycotic aortoiliac pseudoaneurysm treated with an endovascular procedure and follow-up of 36 months. The patient was a white 72-year-old man with pulmonary tuberculosis and a former smoker with hypertension, chronic renal failure, and dyslipidemia. A computed tomographic scan of the abdomen and pelvis revealed a left paravertebral cavity with fluid content and involvement of vertebrae L2–L4. After a surgical repair attempt, the patient was treated with the implant of a bifurcated endoprosthesis. Because it is unlikely that any center has extensive experience in the management of this rare manifestation of the disease, we reviewed the literature for similar cases.

  19. Endovascular Treatment of an Aortoiliac Tuberculous Pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Villegas, Miguel O.; Mereles, Alberto Perez; Tamashiro, Gustavo A.; Dini, Andres E.; Mollon, Ana P.; De Candido, Laura V.; Zelaya, Denis A.; Soledispa-Suarez, Carlos I.; Denato, Sergio; Tamashiro, Alberto; Diaz, Jose A., E-mail: joseantoniodiaz@hotmail.com [Hospital Nacional Prof. Alejandro Posadas, Department of Cardiology, Section of Hemodinamia (Argentina)

    2013-04-15

    We report a rare case of a tuberculous mycotic aortoiliac pseudoaneurysm treated with an endovascular procedure and follow-up of 36 months. The patient was a white 72-year-old man with pulmonary tuberculosis and a former smoker with hypertension, chronic renal failure, and dyslipidemia. A computed tomographic scan of the abdomen and pelvis revealed a left paravertebral cavity with fluid content and involvement of vertebrae L2-L4. After a surgical repair attempt, the patient was treated with the implant of a bifurcated endoprosthesis. Because it is unlikely that any center has extensive experience in the management of this rare manifestation of the disease, we reviewed the literature for similar cases.

  20. Correção endovascular de aneurisma de aorta abdominal e artéria ilíaca comum esquerda em paciente com hemofilia C grave Endovascular repair of abdominal aortic aneurysm and left common iliac artery in a patient with severe hemophilia C

    Directory of Open Access Journals (Sweden)

    Sergio Quilici Belczak

    2012-03-01

    Full Text Available A deficiência do fator XI, também conhecida como hemofilia C, é uma doença hematológica hereditária rara, que se manifesta clinicamente com hemorragia persistente após cirurgias, traumas, menorragias e extrações dentárias. Neste artigo, relatou-se a correção endovascular de um paciente com aneurisma de aorta e de artéria ilíaca comum esquerda em um paciente portador de deficiência major do fator XI (atividade do fator XI inferior a 20%. O procedimento foi realizado com sucesso, com o manuseio do distúrbio da coagulação por meio da infusão de plasma fresco no pré-operatório imediato e no pós-operatório, e controle laboratorial da coagulação do paciente.Factor XI deficiency, also known as hemophilia C, is a rare hereditary blood disease that manifests with persistent bleeding after surgery, trauma, menorrhagia, and dental extractions. This article reports an endovascular repair of a patient diagnosed with an aortic and left common iliac aneurysm, with severe factor XI deficiency (factor XI activity below 20%. The procedure was successfully performed with management of the coagulation disorder by preoperative and postoperative infusion of plasma and laboratory control of the coagulation.

  1. The Weekend Effect in AAA Repair.

    Science.gov (United States)

    O'Donnell, Thomas F X; Li, Chun; Swerdlow, Nicholas J; Liang, Patric; Pothof, Alexander B; Patel, Virendra I; Giles, Kristina A; Malas, Mahmoud B; Schermerhorn, Marc L

    2018-04-18

    Conflicting reports exist regarding whether patients undergoing surgery on the weekend or later in the week experience worse outcomes. We identified patients undergoing abdominal aortic aneurysm (AAA) repair in the Vascular Quality Initiative between 2009 and 2017 [n = 38,498; 30,537 endovascular aneurysm repair (EVAR) and 7961 open repair]. We utilized mixed effects logistic regression to compare adjusted rates of perioperative mortality based on the day of repair. Tuesday was the most common day for elective repair (22%), Friday for symptomatic repairs (20%), and ruptured aneurysms were evenly distributed. Patients with ruptured aneurysms experienced similar adjusted mortality whether they underwent repair during the week or on weekends. Transfers of ruptured AAA were more common over the weekend. However, patients transferred on the weekend experienced higher adjusted mortality than those transferred during the week (28% vs 21%, P = 0.02), despite the fact that during the week, transferred patients actually experienced lower adjusted mortality than patients treated at the index hospital (21% vs 31%, P AAA repair. However, patients with ruptured AAA transferred on the weekend experienced higher mortality than those transferred during the week, suggesting a need for improvement in weekend transfer processes.

  2. Fitness plus American Society of Anesthesiologists grade improve outcome prediction after endovascular aneurysm repair.

    Science.gov (United States)

    Boult, Margaret; Cowled, Prue; Barnes, Mary; Fitridge, Robert A

    2017-09-01

    Although the American Society of Anesthesiologists (ASA) grade was established for statistical purposes, it is often used prognostically. However, older patients undergoing elective surgery are typically ASA III, which limits patient stratification. We look at the prognostic effect on early complications and survival of using ASA and self-reported physical fitness to stratify patients undergoing endovascular repair of abdominal aortic aneurysms. Data were extracted from a trial database. All patients were assigned a fitness level (A (fit) or B (unfit)) based on their self-reported ability to walk briskly for 1 km or climb two flights of stairs. Fitness was used to stratify ASA III patients, with fitter patients assigned ASA IIIA and less fit patients ASA IIIB. Outcomes assessed included survival, reinterventions, endoleak, all early and late complications and early operative complications. A combined ASA/fitness scale (II, IIIA, IIIB and IV) correlated with 1- and 3-year survival (1-year P = 0.001, 3-year P = 0.001) and early and late complications (P = 0.001 and P = 0.05). On its own, ASA predicted early complications (P = 0.0004) and survival (1-year P = 0.01, 3-year P = 0.01). Fitness alone was predictive for survival (1-year P = 0.001, 3-year P = 0.001) and late complications (P = 0.009). This study shows that even a superficial assessment of fitness is reflected in surgical outcomes, with fitter ASA III patients showing survival patterns similar to ASA II patients. Physicians should be alert to differences in fitness between patients in the ASA III group, despite similarities based on preexisting severe systemic disease. © 2017 Royal Australasian College of Surgeons.

  3. New image-processing and noise-reduction software reduces radiation dose during complex endovascular procedures.

    Science.gov (United States)

    Kirkwood, Melissa L; Guild, Jeffrey B; Arbique, Gary M; Tsai, Shirling; Modrall, J Gregory; Anderson, Jon A; Rectenwald, John; Timaran, Carlos

    2016-11-01

    procedures with and without Clarity were not significantly different. For all cases, procedure radiation dose to the patient and the primary and assistant operators were significantly decreased in the Clarity group by 60% compared with the non-Clarity group. By procedure type, fluorography dose rates decreased from 44% for fenestrated endovascular repair and up to 70% with lower extremity interventions. Fluoroscopy dose rates also significantly decreased, from about 37% to 47%, depending on procedure type. The AlluraClarity system reduces the patient and primary operator's radiation dose by more than half during CEPs. This feature appears to be an effective tool in lowering the radiation dose while maintaining image quality. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  4. Manejo endovascular de la aorta torácica Endovascular treatment of thoracic aorta

    Directory of Open Access Journals (Sweden)

    Juan G Barrera

    2006-10-01

    Full Text Available En comparación con el tratamiento convencional, la terapia endovascular en aneurisma de aorta torácica, presenta los mejores resultados, por lo que se convierte en el tratamiento de elección para la patología de aorta torácica descendente endovascular, por su baja morbimortalidad perioperatoria. El tratamiento quirúrgico por vía retroperitoneal y/o endovascular para aneurisma de aorta abdominal infrarrenal, resulta ser especialmente seguro en pacientes octogenarios o con alta morbilidad. Esta cohorte institucional presenta resultados perioperatorios y en el seguimiento, similares a los reportados en la literatura mundial.Compared with the conventional treatment, endovascular therapy in thoracic aortic aneurysm shows the best results, being the election treatment for the pathology of the descending thoracic aorta, due to its low peri-operative morbid-mortality. Surgical treatment by retro-peritoneal route and/or endovascular for infra-renal abdominal aortic aneurysm is especially safe in octogenarian patients or in those with a high mortality rate. This institutional cohort show peri-operative and follow-up results similar to those reported in the world literature.

  5. Abdominal aortic aneurysm calcification and thrombus volume are not associated with outcome following endovascular abdominal aortic aneurysm repair

    International Nuclear Information System (INIS)

    Rai, Divyajeet; Velu, Ramesh; Tosenovsky, Patrik; Quigley, Francis; Wisniowski, Brendan; Walker, Philip J.; Bradshaw, Barbara; Golledge, Jonathan

    2014-01-01

    Aortic calcification and thrombus have been postulated to worsen outcome following endovascular abdominal aortic aneurysm repair (EVAR). The purpose of this study was to assess the association of abdominal aortic aneurysm (AAA) calcification and thrombus volume with outcome following EVAR using a reproducible, quantifiable computed tomography (CT) assessment protocol. Patients with elective EVAR performed between January 2002 and 2012 at the Townsville Hospital, Mater Private Hospital (Townsville) and Royal Brisbane and Women's Hospital (RBWH) were included if preoperative CTAs were available for analysis. AAA calcification and thrombus volume were measured using a semiautomated workstation protocol. Outcomes were assessed in terms of clinical failure, endoleak (type I, type II) and reintervention. Univariate and multivariate analyses were performed. Median follow-up was 1.7 years and the interquartile range 1.0-3.8 years. One hundred thirty-four patients undergoing elective EVAR were included in the study. Rates of primary clinical success and freedom from reintervention were 82.8 % and 88.9 % at the 24-month follow-up. AAA calcification and thrombus volume were not associated with clinical failure, type I endoleak, type II endoleak or reintervention. AAA calcification and thrombus volume were not associated with poorer outcome after EVAR in this study. (orig.)

  6. Abdominal aortic aneurysm calcification and thrombus volume are not associated with outcome following endovascular abdominal aortic aneurysm repair

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Divyajeet; Velu, Ramesh; Tosenovsky, Patrik; Quigley, Francis [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); The Townsville Hospital, Department of Vascular and Endovascular Surgery, Douglas (Australia); Wisniowski, Brendan; Walker, Philip J. [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); University of Queensland, School of Medicine and Centre for Clinical Research, Department of Vascular Surgery, Royal Brisbane and Women' s Hospital, Herston, QLD (Australia); Bradshaw, Barbara [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); Golledge, Jonathan [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); The Townsville Hospital, Department of Vascular and Endovascular Surgery, Douglas (Australia); University of Queensland, School of Medicine and Centre for Clinical Research, Department of Vascular Surgery, Royal Brisbane and Women' s Hospital, Herston, QLD (Australia)

    2014-08-15

    Aortic calcification and thrombus have been postulated to worsen outcome following endovascular abdominal aortic aneurysm repair (EVAR). The purpose of this study was to assess the association of abdominal aortic aneurysm (AAA) calcification and thrombus volume with outcome following EVAR using a reproducible, quantifiable computed tomography (CT) assessment protocol. Patients with elective EVAR performed between January 2002 and 2012 at the Townsville Hospital, Mater Private Hospital (Townsville) and Royal Brisbane and Women's Hospital (RBWH) were included if preoperative CTAs were available for analysis. AAA calcification and thrombus volume were measured using a semiautomated workstation protocol. Outcomes were assessed in terms of clinical failure, endoleak (type I, type II) and reintervention. Univariate and multivariate analyses were performed. Median follow-up was 1.7 years and the interquartile range 1.0-3.8 years. One hundred thirty-four patients undergoing elective EVAR were included in the study. Rates of primary clinical success and freedom from reintervention were 82.8 % and 88.9 % at the 24-month follow-up. AAA calcification and thrombus volume were not associated with clinical failure, type I endoleak, type II endoleak or reintervention. AAA calcification and thrombus volume were not associated with poorer outcome after EVAR in this study. (orig.)

  7. An anatomic risk model to screen post endovascular aneurysm repair patients for aneurysm sac enlargement.

    Science.gov (United States)

    Png, Chien Yi M; Tadros, Rami O; Beckerman, William E; Han, Daniel K; Tardiff, Melissa L; Torres, Marielle R; Marin, Michael L; Faries, Peter L

    2017-09-01

    Follow-up computed tomography angiography (CTA) scans add considerable postimplantation costs to endovascular aneurysm repairs (EVARs) of abdominal aortic aneurysms (AAAs). By building a risk model, we hope to identify patients at low risk for aneurysm sac enlargement to minimize unnecessary CTAs. 895 consecutive patients who underwent EVAR for AAA were reviewed, of which 556 met inclusion criteria. A Probit model was created for aneurysm sac enlargement, with preoperative aneurysm morphology, patient demographics, and operative details as variables. Our final model included 287 patients and had a sensitivity of 100%, a specificity of 68.9%, and an accuracy of 70.4%. Ninety-nine (35%) of patients were assigned to the high-risk group, whereas 188 (65%) of patients were assigned to the low-risk group. Notably, regarding anatomic variables, our model reported that age, pulmonary comorbidities, aortic neck diameter, iliac artery length, and aneurysms were independent predictors of post-EVAR sac enlargement. With the exception of age, all statistically significant variables were qualitatively supported by prior literature. With regards to secondary outcomes, the high-risk group had significantly higher proportions of AAA-related deaths (5.1% versus 1.1%, P = 0.037) and Type 1 endoleaks (9.1% versus 3.2%, P = 0.033). Our model is a decent predictor of patients at low risk for post AAA EVAR aneurysm sac enlargement and associated complications. With additional validation and refinement, it could be applied to practices to cut down on the overall need for postimplantation CTA. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Prevalence and risk factors of type II endoleaks after endovascular aneurysm repair: A meta-analysis.

    Directory of Open Access Journals (Sweden)

    Qiang Guo

    Full Text Available This systematic review and meta-analysis aims to determine the current evidence on risk factors for type II endoleaks after endovascular aneurysm repair (EVAR.A systematic literature search was carried out for studies that evaluated the association of demographic, co-morbidity, and other patient-determined factors with the onset of type II endoleaks. Pooled prevalence of type II endoleaks after EVAR was updated.Among the 504 studies screened, 45 studies with a total of 36,588 participants were included in this review. The pooled prevalence of type II endoleaks after EVAR was 22% [95% confidence interval (CI, 19%-25%]. The main factors consistently associated with type II endoleaks included age [pooled odds ratio (OR, 0.37; 95% CI, 0.31-0.43; P<0.001], smoking (pooled OR, 0.71; 95% CI, 0.55-0.92; P<0.001, patent inferior mesenteric artery (pooled OR, 1.98; 95% CI, 1.06-3.71; P = 0.012, maximum aneurysm diameter (pooled OR, 0.23; 95% CI, 0.17-0.30; P<0.001, and number of patent lumbar arteries (pooled OR, 3.07; 95% CI, 2.81-3.33; P<0.001. Sex, diabetes, hypertension, anticoagulants, antiplatelet, hyperlipidemia, chronic renal insufficiency, types of graft material, and chronic obstructive pulmonary diseases (COPD did not show any association with the onset of type II endoleaks.Clinicians can use the identified risk factors to detect and manage patients at risk of developing type II endoleaks after EVAR. However, further studies are needed to analyze a number of potential risk factors.

  9. Anatomical Features and Early Outcomes of Endovascular Repair of Abdominal Aortic Aneurysm from a Korean Multicenter Registry.

    Science.gov (United States)

    Kwon, Hyunwook; Lee, Do Yun; Choi, Soo Jin Na; Park, Ki Hyuk; Min, Seung-Kee; Chang, Jeong-Hwan; Huh, Seung; Jeon, Yong Sun; Won, Jehwan; Byun, Seung Jae; Park, Sang Jun; Jang, Lee Chan; Kwon, Tae-Won

    2015-09-01

    To introduce a nation-based endovascular aneurysm repair (EVAR) registry in South Korea and to analyze the anatomical features and early clinical outcomes of abdominal aortic aneurysms (AAA) in patients who underwent EVAR. The Korean EVAR registry (KER) was a template-based online registry developed and established in 2009. The KER recruited 389 patients who underwent EVAR from 13 medical centers in South Korea from January 2010 to June 2010. We retrospectively reviewed the anatomic features and 30-day clinical outcomes. Initial deployment without open conversion was achieved in all cases and procedure-related 30-day mortality rate was 1.9%. Anatomic features showed the following variables: proximal aortic neck angle 48.8±25.7° (mean±standard deviation), vertical neck length 35.0±17.2 mm, aneurysmal sac diameter 57.2±14.2 mm, common iliac artery (CIA) involvement in 218 (56.3%) patients, and median right CIA length 34.9 mm. Two hundred and nineteen (56.3%) patients showed neck calcification, 98 patients (25.2%) had neck thrombus, and the inferior mesenteric arteries of 91 patients (23.4%) were occluded. Anatomical features of AAA in patients from the KER were characterized as having angulated proximal neck, tortuous iliac artery, and a higher rate of CIA involvement. Long-term follow-up and ongoing studies are required.

  10. The risk of endoleak following stent covering of the internal iliac artery during endovascular aneurysm repair

    International Nuclear Information System (INIS)

    Rajesparan, K.; Partridge, W.; Refson, J.; Abidia, A.; Aldin, Z.

    2014-01-01

    Aim: To investigate the risk of endoleak during endovascular aneurysm repair (EVAR) involving the distal common iliac artery (CIA) when the internal iliac artery (IIA) is covered without prior coil embolization. Materials and methods: Retrospective analysis of 145 (125 men, 20 women) consecutive EVAR cases. Clinical notes and radiological images were reviewed, and data collected on patient demographics, aneurysm morphology, covering of the IIA with or without embolization, presence of endoleaks, and patient symptoms relating to IIA ischaemia. Results: A total of 29 IIAs (10%) were covered in a total of 25 patients. Seven IIAs (24%) were embolized before stent covering (Embolization group), and 22 IIAs (76%) were covered only without embolization (Cover group). There was no statistically significant difference in the mean size of the abdominal aortic aneurysm diameter or CIA diameter between each group. No endoleaks from IIA retrograde filling were found in either group. Conclusion: The results of the present study do not support the traditional view that coverage of the IIA without prior embolization carries a high risk of endoleak, with no endoleaks seen in all 22 cases. Large-scale trials are required. However, the advent of branched-stenting techniques and the emergence of their success in long-term follow-up may preclude the former. - Highlights: • No EVAR endoleaks due to retrograde filling of the internal iliac artery (IIA). • No increased risk of endoleak with stent coverage of the IIA without embolisation. • Current evidence does not support traditional views

  11. Endovascular Aortic Aneurysm Repair with the Talent Stent-Graft: Outcomes in Patients with Large Iliac Arteries

    International Nuclear Information System (INIS)

    England, Andrew; Butterfield, John S.; McCollum, Charles N.; Ashleigh, Raymond J.

    2008-01-01

    The purpose of this study is to report outcomes following endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) in patients with ectatic common iliac arteries (CIAs). Of 117 AAA patients treated by EVAR between 1998 and 2005, 87 (74%) had CIAs diameters 18 but <25 mm. All patients were treated with Talent stent-grafts, 114 bifurcated and 3 AUI devices. Departmental databases and patient records were reviewed to assess outcomes. Technical success, iliac-related outcome, and iliac-related reintervention (IRSI) were analyzed. Patients with EVAR extending into the external iliac artery were excluded. Median (range) follow-up for the study group was 24 (1-84) months. Initial technical success was 98% for CIAs <18 mm and 100% for CIAs ≥18 mm (p = 0.551). There were three distal type I endoleaks (two in the ectatic group) and six iliac limb occlusions (one in an ectatic patient); there were no statistically significant differences between groups (p = 0.4). There were nine IRSIs (three stent-graft extensions, six femorofemoral crossover grafts); three of these patients had one or both CIAs ≥18 mm (p = 0.232). One-year freedom from IRSI was 92% ± 3% and 84% ± 9% for the <18-mm and ≥18-mm CIA groups, respectively (p = 0.232). We conclude that the treatment of AAA by EVAR in patients with CIAs 18-24 mm appears to be safe and effective, however, it may be associated with more frequent reinterventions.

  12. Complete ten-year follow-up after endovascular abdominal aortic aneurysm repair: Survival and causes of death

    International Nuclear Information System (INIS)

    Wibmer, Andreas; Nolz, Richard; Teufelsbauer, Harald; Kretschmer, Georg; Prusa, Alexander M.; Funovics, Martin; Lammer, Johannes; Schoder, Maria

    2012-01-01

    Purpose: To analyze the hazard and causes of death after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms during a complete ten year follow-up. Methods: This is a retrospective clinical study of 130 consecutive patients undergoing EVAR between 1995 and 1998. One-hundred twenty-one patients (93.1%) were treated with first-generation stentgrafts and nine patients (6.9%) received second-generation devices. All patients completed a follow-up of at least 10 years, unless death occurred before then. Time and causes of death were provided by the Austrian central register of deaths. Results: The median follow-up was 7.6 years, and the 130 patients had 968.5 person-years of follow-up. The ten-year mortality rate was 62.3%. Cardiovascular events were the most frequent causes of death, with a 3.9 incidence rate per 100 person-years. Cancer death and death due to other causes occurred in 2.1 and 1.8 cases per 100 person-years, respectively. Lethal late aneurysm rupture happened in 4.6% (n = 6), which corresponds to an annual incidence rate of 0.6 per 100 person-years. All of those patients had been treated with first-generation devices. Conclusions: Cardiovascular events were the most frequent cause of death after EVAR, followed by malignancy and other diseases. The risk of dying from secondary rupture was clearly lower than that of death due to other reasons during ten years after EVAR, even in patients with first-generation stentgrafts.

  13. International trends in patient selection for elective endovascular aneurysm repair: sicker patients with safer anatomy leading to improved 1-year survival.

    Science.gov (United States)

    Fitridge, Robert A; Boult, Margaret; Mackillop, Clare; De Loryn, Tania; Barnes, Mary; Cowled, Prue; Thompson, Matthew M; Holt, Peter J; Karthikesalingam, Alan; Sayers, Robert D; Choke, Edward; Boyle, Jonathan R; Forbes, Thomas L; Novick, Teresa V

    2015-02-01

    To review the trends in patient selection and early death rate for patients undergoing elective endovascular repair of infrarenal abdominal aortic aneurysms (EVAR) in 3 countries. For this study, audit data from 4,163 patients who had undergone elective infrarenal EVAR were amalgamated. The data originated from Australia, Canada (Ontario), and England (London, Cambridge, and Leicester). Statistical analyses were undertaken to determine whether patient characteristics and early death rate varied between and within study groups and over time. The study design was retrospective analysis of data collected prospectively between 1999 and 2012. One-year survival improved over time (P = 0.0013). Canadian patients were sicker than those in Australia or England (P international comparison, several trends were noted including improved 1-year survival despite declining patient health (as measured by increasing ASA status). This may reflect greater knowledge regarding EVAR that centers from different countries have gained over the last decade and improved medical management of patients with aneurysmal disease. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Detailed thermal simulation of fenestration; Simulacion termica detallada de una ventana

    Energy Technology Data Exchange (ETDEWEB)

    Fissore Sch, Adelqui; Tartari, Paula [Universidad de Concepcion (Chile). Facultad de Ingenieria. Dept. de Ingenieria Mecanica]. E-mail: afissore@udec.cl; ptartari@udec.cl; Hernandez C, Gaston [Universidad del Bio-Bio, Concepcion (Chile). Facultad de Ingenieria. Dept. de Ingenieria Mecanica]. E-mail: ghernand@ubiobio.cl

    2000-07-01

    In this paper a new model for heat balance of a window is proposed. The objective of the model is to solve accurately the heat balance on a single glass window in a moderate climate. This procedure will allow the designer to calculate the main parameters of a fenestration (surface, orientation, overhangs, etc.), minimizing the energy consumption for a specific enclosure (including heating, air conditioning and lighting). The present study is mainly focused on problems related with the internal long wave radiation calculations, and secondly on the effect of internal convection coefficient on the heat balance. A comparison between the results obtained using this model and those obtained with other current models is included in the second part of the paper. The importance of using the right internal convection coefficient on the heat balance of fenestration for this kind of application is also analyzed. (author)

  15. Type A dissection following endovascular repair of type B dissection

    International Nuclear Information System (INIS)

    Juszkat, R.; Zabicki, M.; Jemielity, M.; Buczkowski, P.; Urbanowicz, T.

    2009-01-01

    Background: We present a patient, who was treated with thoracic stentgraft implantation, because of acute type B aortic dissection (according to Stanford classification). The endovascular procedure was performed without any complications. Case Report: The patient was discharged in the 3 rd postprocedural day and was transferred to another hospital for further recovery. Nine days after the procedure, the patient was readmitted in cardiogenic shock to the Cardiac Surgery Department. The patient was immediately operated on, after dissection of the ascending aorta and pericardial tamponade had been diagnosed in transthoracic echocardiography. Conclusions: Total replacement of the aortic arch and its ascending part was performed successfully. The surgery was carried out in deep hypothermia with temporary circulatory arrest. The patient was discharged from the Cardiac Surgery Unit 15 days after the surgery, and transferred to another unit for further recovery. (authors)

  16. Leakage Characteristics of Dual-Cannula Fenestrated Tracheostomy Tubes during Positive Pressure Ventilation: A Bench Study

    Directory of Open Access Journals (Sweden)

    Thomas Berlet

    2016-01-01

    Full Text Available This study compared the leakage characteristics of different types of dual-cannula fenestrated tracheostomy tubes during positive pressure ventilation. Fenestrated Portex® Blue Line Ultra®, TRACOE® twist, or Rüsch® Traceofix® tracheostomy tubes equipped with nonfenestrated inner cannulas were tested in a tracheostomy-lung simulator. Transfenestration pressures and transfenestration leakage rates were measured during positive pressure ventilation. The impact of different ventilation modes, airway pressures, temperatures, and simulated static lung compliance settings on leakage characteristics was assessed. We observed substantial differences in transfenestration pressures and transfenestration leakage rates. The leakage rates of the best performing tubes were <3.5% of the delivered minute volume. At body temperature, the leakage rates of these tracheostomy tubes were <1%. The tracheal tube design was the main factor that determined the leakage characteristics. Careful tracheostomy tube selection permits the use of fenestrated tracheostomy tubes in patients receiving positive pressure ventilation immediately after stoma formation and minimises the risk of complications caused by transfenestration gas leakage, for example, subcutaneous emphysema.

  17. Endovascular aneurysm exclusion along a femorodistal venous bypass in active Behçet's disease.

    Science.gov (United States)

    Gretener, Silvia B; Do, Dai-Do; Baumgartner, Iris; Dinkel, Hans-Peter; Schmidli, Jürg; Birrer, Manuela

    2002-10-01

    To report the endovascular repair of dual aneurysms along a femorodistal venous bypass graft in a patient with Behçet's disease. A 55-year-old man of middle European ancestry with Behçet's disease had dual aneurysms evolve along the proximal segment of a femorodistal venous bypass that had been implanted 2.5 years earlier for recurrent false aneurysm formation. Owing to the lack of suitable venous conduits and the active nature of the disease, the aneurysms were successfully excluded with overlapping Hemobahn and Jostent endografts; the immunosuppressive therapy was intensified. Rupture of the aneurysms was successfully prevented, but the stent-grafts thrombosed 6 weeks later owing to exacerbation of the underlying disease. Endovascular exclusion of aneurysm in venous bypass grafts in Behçet's disease is feasible. Although the stent-grafts thrombosed, they did prevent rupture of the aneurysms.

  18. A simulator for training in endovascular aneurysm repair: The use of three dimensional printers.

    Science.gov (United States)

    Torres, I O; De Luccia, N

    2017-08-01

    To develop an endovascular aneurysm repair (EVAR) simulation system using three dimensional (3D) printed aneurysms, and to evaluate the impact of patient specific training prior to EVAR on the surgical performance of vascular surgery residents in a university hospital in Brazil. This was a prospective, controlled, single centre study. During 2015, the aneurysms of patients undergoing elective EVAR at São Paulo University Medical School were 3D printed and used in training sessions with vascular surgery residents. The 3D printers Stratasys-Connex 350, Formlabs-Form1+, and Makerbot were tested. Ten residents were enrolled in the control group (five residents and 30 patients in 2014) or the training group (five residents and 25 patients in 2015). The control group performed the surgery under the supervision of a senior vascular surgeon (routine procedure, without simulator training). The training group practised the surgery in a patient specific simulator prior to the routine procedure. Objective parameters were analysed, and a subjective questionnaire addressing training utility and realism was answered. Patient specific training reduced fluoroscopy time by 30% (mean 48 min, 95% confidence interval [CI] 40-58 vs. 33 min, 95% CI 26-42 [p training useful and realistic, and reported that it increased their self confidence. The 3D printers Form1+ (using flexible resin) and Makerbot (using silicone) provided the best performance based on simulator quality and cost. An EVAR simulation system using 3D printed aneurysms was feasible. The best results were obtained with the 3D printers Form1+ (using flexible resin) and Makerbot (using silicone). Patient specific training prior to EVAR at a university hospital in Brazil improved residents' surgical performance (based on fluoroscopy time, surgery time, and volume of contrast used) and increased their self confidence. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Total Percutaneous Aortic Repair: Midterm Outcomes

    International Nuclear Information System (INIS)

    Bent, Clare L.; Fotiadis, Nikolas; Renfrew, Ian; Walsh, Michael; Brohi, Karim; Kyriakides, Constantinos; Matson, Matthew

    2009-01-01

    The purpose of this study was to examine the immediate and midterm outcomes of percutaneous endovascular repair of thoracic and abdominal aortic pathology. Between December 2003 and June 2005, 21 patients (mean age: 60.4 ± 17.1 years; 15 males, 6 females) underwent endovascular stent-graft insertion for thoracic (n = 13) or abdominal aortic (n = 8) pathology. Preprocedural computed tomographic angiography (CTA) was performed to assess the suitability of aorto-iliac and common femoral artery (CFA) anatomy, including the degree of CFA calcification, for total percutaneous aortic stent-graft repair. Percutaneous access was used for the introduction of 18- to 26-Fr delivery devices. A 'preclose' closure technique using two Perclose suture devices (Perclose A-T; Abbott Vascular) was used in all cases. Data were prospectively collected. Each CFA puncture site was assessed via clinical examination and CTA at 1, 6, and 12 months, followed by annual review thereafter. Minimum follow-up was 36 months. Outcome measures evaluated were rates of technical success, conversion to open surgical repair, complications, and late incidence of arterial stenosis at the site of Perclose suture deployment. A total of 58 Perclose devices were used to close 29 femoral arteriotomies. Outer diameters of stent-graft delivery devices used were 18 Fr (n = 5), 20 Fr (n = 3), 22 Fr (n = 4), 24 Fr (n = 15), and 26 Fr (n = 2). Percutaneous closure was successful in 96.6% (28/29) of arteriotomies. Conversion to surgical repair was required at one access site (3.4%). Mean follow-up was 50 ± 8 months. No late complications were observed. By CT criteria, no patient developed a >50% reduction in CFA caliber at the site of Perclose deployment during the study period. In conclusion, percutaneous aortic stent-graft insertion can be safely performed, with a low risk of both immediate and midterm access-related complications.

  20. Multiple Re-entry Closures After TEVAR for Ruptured Chronic Post-dissection Thoraco-abdominal Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    R. Kinoshita

    Full Text Available Introduction: Although thoracic endovascular aortic repair (TEVAR has become a promising treatment for complicated acute type B dissection, its role in treating chronic post-dissection thoraco-abdominal aortic aneurysm (TAA is still limited owing to persistent retrograde flow into the false lumen (FL through abdominal or iliac re-entry tears. Report: A case of chronic post-dissection TAA treatment, in which a dilated descending FL ruptured into the left thorax, is described. The primary entry tear was closed by emergency TEVAR and multiple abdominal re-entries were closed by EVAR. In addition, major re-entries at the detached right renal artery and iliac bifurcation were closed using covered stents. To close re-entries as far as possible, EVAR was carried out using the chimney technique, and additional aortic extenders were placed above the coeliac artery. A few re-entries remained, but complete FL thrombosis of the rupture site was achieved. Follow-up computed tomography showed significant shrinkage of the FL. Discussion: In treating post-dissection TAA, entry closure by TEVAR is sometimes insufficient, owing to persistent retrograde flow into the FL from abdominal or iliac re-entries. Adjunctive techniques are needed to close these distal re-entries to obtain complete FL exclusion, especially in rupture cases. Recently, encouraging results of complete coverage of the thoraco-abdominal aorta with fenestrated or branched endografts have been reported; however, the widespread employment of such techniques appears to be limited owing to technical difficulties. The present method with multiple re-entry closures using off the shelf and immediately available devices is an alternative for the endovascular treatment of post-dissection TAA, especially in the emergency setting. Keywords: Aortic dissection, Ruptured aortic aneurysm, Post-dissection thoracoabdominal aortic aneurysm, Endovascular aortic repair, Reentry closure, Endovascular procedures

  1. Endovascular Embolization of Intracranial Infectious Aneurysms in Patients Undergoing Open Heart Surgery Using n-Butyl Cyanoacrylate.

    Science.gov (United States)

    Cheng-Ching, Esteban; John, Seby; Bain, Mark; Toth, Gabor; Masaryk, Thomas; Hui, Ferdinand; Hussain, Muhammad Shazam

    2017-03-01

    Mycotic aneurysms are a serious complication of infective endocarditis with increased risk of intracranial hemorrhage. Patients undergoing open heart surgery for valve repair or replacement are exposed to anticoagulants, increasing the risk of aneurysm bleeding. These patients may require endovascular or surgical aneurysm treatment prior to heart surgery, but data on this approach are scarce. Retrospective review of consecutive patients with infectious endocarditis and mycotic aneurysms treated endovascularly with Trufill n-butyl cyanoacrylate (n-BCA) at the Cleveland Clinic between January 2013 and December 2015. Nine patients underwent endovascular treatment of mycotic aneurysms with n-BCA (mean age of 39 years). On imaging, 4 patients had intracerebral hemorrhage, 2 had multiple embolic infarcts, and the rest had no imaging findings. Twelve mycotic aneurysms were detected (3 patients with 2 aneurysms). Seven aneurysms were in the M4 middle cerebral artery segment, 4 in the posterior cerebral artery distribution, and 1 in the callosomarginal branch. n-BCA was diluted in ethiodized oil (1:1 to 1:2). Embolization was achieved in a single rapid injection with immediate microcatheter removal. Complete aneurysm exclusion was achieved in all cases without complications. All patients underwent open heart surgery and endovascular embolization within a short interval, 2 with both procedures on the same day. There were no new hemorrhages after aneurysm embolization. Endovascular embolization of infectious intracranial aneurysms with liquid embolics can be performed successfully in critically ill patients requiring immediate open heart surgery and anticoagulation. Early embolization prior to and within a short interval from open heart surgery is feasible.

  2. Computational Combination of the Optical Properties of Fenestration Layers at High Directional Resolution

    Directory of Open Access Journals (Sweden)

    Lars Oliver Grobe

    2017-03-01

    Full Text Available Complex fenestration systems typically comprise co-planar, clear and scattering layers. As there are many ways to combine layers in fenestration systems, a common approach in building simulation is to store optical properties separate for each layer. System properties are then computed employing a fast matrix formalism, often based on a directional basis devised by JHKlems comprising 145 incident and 145 outgoing directions. While this low directional resolution is found sufficient to predict illuminance and solar gains, it is too coarse to replicate the effects of directionality in the generation of imagery. For increased accuracy, a modification of the matrix formalism is proposed. The tensor-tree format of RADIANCE, employing an algorithm subdividing the hemisphere at variable resolutions, replaces the directional basis. The utilization of the tensor-tree with interfaces to simulation software allows sharing and re-use of data. The light scattering properties of two exemplary fenestration systems as computed employing the matrix formalism at variable resolution show good accordance with the results of ray-tracing. Computation times are reduced to 0.4% to 2.5% compared to ray-tracing through co-planar layers. Imagery computed employing the method illustrates the effect of directional resolution. The method is supposed to foster research in the field of daylighting, as well as applications in planning and design.

  3. Endovascular repair of multiple infrageniculate aneurysms in a patient with vascular type Ehlers-Danlos syndrome.

    Science.gov (United States)

    Domenick, Natalie; Cho, Jae S; Abu Hamad, Ghassan; Makaroun, Michel S; Chaer, Rabih A

    2011-09-01

    Patients with vascular type Ehler-Danlos syndrome can develop aneurysms in unusual locations. We describe the case of a 33-year-old woman with vascular type Ehlers-Danlos syndrome who developed metachronous tibial artery aneurysms that were sequentially treated with endovascular means. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  4. Management of aorto-esophageal fistula secondary after thoracic endovascular aortic repair: a review of literature.

    Science.gov (United States)

    Uno, Kaname; Koike, Tomoyuki; Takahashi, Seiichi; Komazawa, Daisuke; Shimosegawa, Tooru

    2017-10-01

    Aorto-esophageal fistula (AEF) is a rare and lethal entity, and the difficulty of making diagnosis of AEF is well-known. As promising results in the short-term effectiveness of thoracic endovascular aortic repair (TEVAR) promote its usage, the occurrence of AEF after TEVAR (post-TEVAR AEF) increases as one of the major complications. Therefore, we provide a review concerning the management strategy of post-TEVAR AEF. Although its representative symptom was reported as the triad of mid-thoracic pain and sentinel hematemesis followed by massive hematemesis, the symptom-free interval between sentinel hemorrhage and massive exsanguination is unpredictable. However, the physiological condition represents a surgical contraindication. Accordingly, early diagnosis is important, but either CT or esophago-gastro-duodenoscopy rarely depicts a typical image. The formation of post-TEVAR AEF might be associated with the infection of micro-organisms, which is uncontrollable with anti-biotic administration. The current first-line strategy is combination therapy as follows, (1) to control bleeding by TEVAR in the urgent phase, and (2) radical debridement and aortic/esophageal re-construction in the semi-urgent phase. In view of the high mortality and morbidity rate, it is proposed that the choice in treatment strategies might be affected by patient`s condition, size of the wall defects and the etiology of AEF. Practically, we should keep in mind the importance of making an early diagnosis and, once a suspicious symptom has occurred in a patient with a history of TEVAR, the existence of post-TEVAR AEF should be suspected. A prospective registry together with more developed technologies will be needed to establish a future strategy.

  5. Supraorbital Keyhole Microsurgical Fenestration of Symptomatic Temporal Arachnoid Cysts in Children: Advantages and Limitations.

    Science.gov (United States)

    Elkheshin, Sherif; Soliman, Ahmed

    2017-01-01

    To investigate the impact of endoscope-assisted microsurgical fenestration on temporal arachnoid cysts, and to determine the advantages and limitations of the technique. Twenty-five children with symptomatic temporal arachnoid cysts were operated via eyebrow supraorbital keyhole microsurgical fenestration targeting the medial cyst wall. Preoperative magnetic resonance imaging (MRI) of the brain was done for all patients. Preoperative clinical presentation of the patients included headache (80%), nausea & vomiting (64%), drug resistant epilepsy (52%), macrocephaly (12%) papilledema (28%), motor weakness in the form of right-sided hemiparesis (12%) and cranial nerve palsy. Postoperative complete subsidence of headache was noted in 50%, while 20% remained unchanged. Drug resistant epilepsy improved in 69% of the patients. Postoperative MRI showed initial decrease in cyst volume as early as 3 months, only in a range of 5-12% volume reduction, and the late follow-up done at 6 and 18 months continued to show further reduction reported to be significant (p CSF) collection was the most common complication (20%). Only 1 patient experienced CSF leak mandating cysto-peritoneal shunting. Conclusıon: Eyebrow supraorbital keyhole microsurgical fenestration for temporal arachnoid cysts can be performed with a fairly low risk of complications and yields a favorable improvement in clinical and neuroimaging outcomes.

  6. Low mortality rates after endovascular aortic repair expand use to high-risk patients.

    Science.gov (United States)

    Adkar, Shaunak S; Turner, Megan C; Leraas, Harold J; Gilmore, Brian F; Nag, Uttara; Turley, Ryan S; Shortell, Cynthia K; Mureebe, Leila

    2018-02-01

    The 2010 endovascular aneurysm repair (EVAR) trial 2 (EVAR 2) reported that patients with comorbidity profiles rendering them unfit for open aneurysm repair who underwent EVAR did not experience a survival advantage compared with those who did not undergo intervention. These patients experienced a 30-day mortality of 7.3%, whereas reports from similar cohorts reported far lower mortality rates. The primary objective of our study was to compare the incidence of 30-day mortality in low- and high-risk patients undergoing EVAR in a contemporary data set, using patient risk stratification criteria from EVAR 2. Secondarily, we sought to identify risk factors associated with a disproportionate contribution to 30-day mortality risk. Data were obtained from the 2005 to 2013 American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) Participant Use Data Files (N = 24,813). Patients were included in the high-risk cohort with the presence of renal, respiratory, or cardiac preoperative criteria alone or in combination. Renal impairment criteria were defined as dialysis and creatinine concentration >2.26 mg/dL. Respiratory impairment criteria included history of chronic obstructive pulmonary disease and preoperative ventilator support. Cardiac impairment criteria included history of myocardial infarction, congestive heart failure, angina, and prior coronary intervention. Patient and procedural characteristics and 30-day postoperative outcomes were compared using Pearson χ 2 tests for categorical variables and Wilcoxon rank sum tests for continuous variables. Among 24,813 patients undergoing EVAR, 12,043 (48%) patients were characterized as high risk (at least one impairment criterion); 12,770 (52%) patients were stratified as low risk. The 30-day mortality rate was 1.9% in the high-risk cohort compared with the 7.3% reported by EVAR 2, and it was higher in the high-risk cohort compared with the low-risk cohort (1.9% vs 0.9%; P < .001). Whereas the

  7. Innovative postmarket device evaluation using a quality registry to monitor thoracic endovascular aortic repair in the treatment of aortic dissection.

    Science.gov (United States)

    Beck, Adam W; Lombardi, Joseph V; Abel, Dorothy B; Morales, J Pablo; Marinac-Dabic, Danica; Wang, Grace; Azizzadeh, Ali; Kern, John; Fillinger, Mark; White, Rodney; Cronenwett, Jack L; Cambria, Richard P

    2017-05-01

    United States Food and Drug Administration (FDA)-mandated postapproval studies have long been a mainstay of the continued evaluation of high-risk medical devices after initial marketing approval; however, these studies often present challenges related to patient/physician recruitment and retention. Retrospective single-center studies also do not fully represent the spectrum of real-world performance nor are they likely to have a sufficiently large enough sample size to detect important signals. In recent years, The FDA Center for Devices and Radiological Health has been promoting the development and use of patient registries to advance infrastructure and methodologies for medical device investigation. The FDA 2012 document, "Strengthening the National System for Medical Device Post-market Surveillance," highlighted registries as a core foundational infrastructure when linked to other complementary data sources, including embedded unique device identification. The Vascular Quality Initiative (VQI) thoracic endovascular aortic repair for type B aortic dissection project is an innovative method of using quality improvement registries to meet the needs of device evaluation after market approval. Here we report the organization and background of this project and highlight the innovation facilitated by collaboration of physicians, the FDA, and device manufacturers. This effort used an existing national network of VQI participants to capture patients undergoing thoracic endovascular aortic repair for acute type B aortic dissection within a registry that aligns with standard practice and existing quality efforts. The VQI captures detailed patient, device, and procedural data for consecutive eligible cases under the auspices of a Patient Safety Organization (PSO). Patients were divided into a 5-year follow-up group (200 acute; 200 chronic dissections) and a 1-year follow-up group (100 acute; 100 chronic). The 5-year cohort required additional imaging details, and the 1-year

  8. Prevalence of fenestrated basilar artery with magnetic resonance angiography: a transversal study.

    Science.gov (United States)

    Arráez-Aybar, L A; Villar-Martin, A; Poyatos-Ruiperez, C; Rodriguez-Boto, G; Arrazola-Garcia, J

    2013-08-01

    Fenestration of the basilar artery (BA) is a rare anatomical variation in comparison to those of the other intracranial arteries constituting the cerebral arterial circle. The incidence is difficult to ascertain and data vary according to type of series and modalities of detection. Basilar artery fenestration (BAF) has been reported in association with arteriovenous malformations, vascular variants, other developmental anomalies and neurovascular conflicts as a consequence of relations between the arterial branches of the BA and the nerves and other structures in the posterior cranial fossa. However, the real clinical interest of BAF is due to the possible formation of an aneurysm at the junction of the fenestrated segment and less frequently to the thrombosis of the vessels. With the aim to establish the prevalence of BAF in our population, we made a transversal pilot study of the first 200 MR angiographies performed on patients attending for the first time to control their base pathology (vascular or not). We have described three patients with this condition (representing a prevalence of 1.5 % on MR angiography) to shed additional light on this anomaly, two cases located at 1/3 proximal end (type 1-BAF) and one case located at joint 1/3 medium-1/3 distal end, locating distal to the anterior inferior cerebellar artery (type 4-BAF). In neither case was any other lesion found (i.e. aneurysm, infarctions, ischemia or thromboembolism). The pertinent clinical anatomy and embryological basis for this variation are reviewed, and the possible clinical implications and associated findings are discussed.

  9. A Novel Fenestration Technique for Abdominal Aortic Dissection Membranes Using a Combination of a Needle Re-entry Catheter and the “Cheese-wire” Technique

    International Nuclear Information System (INIS)

    Kos, Sebastian; Gürke, Lorenz; Jacob, Augustinus L.

    2011-01-01

    Purpose: This study was designed to demonstrate the applicability of a combined needle-based re-entry catheter and “cheese-wire” technique for fenestration of abdominal aortic dissection membranes. Methods: Four male patients (mean age: 65 years) with acute complicated aortic type B dissections were treated at our institution by fenestrating the abdominal aortic dissection membrane using a hybrid technique. This technique combined an initial membrane puncture with a needle-based re-entry catheter using a transfemoral approach. A guidewire was passed through the re-entry catheter and across the membrane. Using a contralateral transfemoral access, this guidewire was then snared, creating a through-and-through wire access. The membrane was then fenestrated using the cheese-wire maneuver. Results: We successfully performed: (a) membrane puncture; (b) guidewire passage; (c) guidewire snaring; and (d) cheese-wire maneuver in all four cases. After this maneuver, decompression of the false lumen and acceptable arterial inflow into the true lumen was observed in all cases. The dependent visceral arteries were reperfused. In one case, portions of the fenestrated membrane occluded the common iliac artery, which was immediately and successfully stented. In another case, long-standing intestinal hypoperfusion before the fenestration resulted in reperfusion-related shock and intraoperative death of the patient. Conclusions: The described hybrid approach for fenestration of dissection membranes is technically feasible and may be established as a therapeutic method in cases with a complicated type B dissection.

  10. Aortic dissection. Basic aspects and endovascular management

    International Nuclear Information System (INIS)

    Jaramillo, Nicolas I; Alviar, Carlos I

    2005-01-01

    Treatment of thoracic aortic pathology is complicated by the morbidity associated to the surgical procedure and to the frailty of an elderly and difficult population. Surgical operation in this kind of population frequently bears a significant incidence of death and long-term disability. In an effort to reduce the incidence of negative outcomes, minimally invasive techniques in the form of endovascular stenting have been introduced during the past decade. The technology, originally described by Parodi, and initially designed for its use in abdominal aortic aneurysms, has been adapted for the treatment of thoracic aortic aneurysms. Furthermore, an improved understanding of the pathophysiology and the natural history of thoracic aortic disease as well as the analysis of the outcomes have facilitated our treatment decisions in terms of the timing for an appropriate intervention. Treatment of thoracic aortic dissection using endovascular Stent is one of the more recent advances in this condition and is receiving increasing attention, as it is a less invasive alternative to an open surgical repair. Although this technology is still innovative, significant improvements have been made lately in the design and deployment of the endovascular Stent-grafts. These prostheses have been increasingly used to treat aneurysms, dissections and traumatic ruptures, as well as giant penetrating ulcers and intramural hematomas of the descending thoracic aorta with good early and mid-term outcomes. The rareness, complexity and severity of the pathology and the theoretically high risk of complications should render the surgeon extremely cautious especially with young patients. Conceptually, the endo luminal treatment in the acute phase seems to be the solution and will probably become a preferred therapy while technical refinement is under way. Worldwide experience is growing and with this a better understanding of the indications and limitations of this innovative therapy will be

  11. The MRI appearance of the optic nerve sheath following fenestration for benign intracranial hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Sallomi, D.; Taylor, H.; Hibbert, J.; Sanders, M.D.; Spalton, D.J.; Tonge, K. [Guys and St. Thomas` Hospitals, London (United Kingdom)

    1998-09-01

    Optic nerve fenestration is carried out in cases of severe benign intracranial hypertension. This study aimed to monitor the optic nerve sheath appearances and orbital changes that occur following this procedure. The eight patients were all female with an average age of 37.3 years and a range of 20-58 years. The duration of symptoms was 2-6 years. Symptoms included headaches, diplopia and visual obscurations. Examination revealed severe papilledema. All investigations, including MRI, biochemical and immunological tests, were negative. Patients had fenestration of a 2 mm x 3 mm segment of the medial aspect of the optic nerve sheath. Imaging was obtained with a 1 T MRI machine using a head coil. Coronal, axial and sagittal 3 mm contiguous sections using STIR sequences with TR 4900 ms, IT 150 ms and TE 60 ms were obtained. Five patients showed clinical improvement. The post-operative MRI findings in four of these included a decreased volume of cerebrospinal fluid (CSF) around the optic nerve sheaths and a localized collection of fluid within the orbit. There were no MRI changes in the three patients with no clinical improvement. Decreased CSF volume around the optic nerve and a fluid collection within the orbit may indicate a favorable outcome in optic nerve fenestration. (orig.) With 3 figs., 12 refs.

  12. Celiac Trunk Embolization, as a Means of Elongating Short Distal Descending Thoracic Aortic Aneurysm Necks, Prior to Endovascular Aortic Repair

    International Nuclear Information System (INIS)

    Belenky, Alexander; Haddad, Menashe; Idov, Igor; Knizhnik, Michael; Litvin, Sergey; Bachar, Gil N.; Atar, Eli

    2009-01-01

    The purpose of this study was to report our experience in elongating short distal necks of descending thoracic aortic aneurysms (DTAAs) by coil embolization of the celiac trunk prior to endovascular aneurysm repair (EVAR). During 6 years seven patients (five men and two women; mean age, 74) who had DTAAs with short distal necks unsuitable for conventional EVAR, and well patent superior and inferior mesenteric arteries based on CT, were treated in one session with EVAR after the celiac trunk was coil embolized to elongate the neck. All patients were followed by CT every 3 months in the first year and every 6 months thereafter. Technical success was achieved in all patients, and no early or late ischemic complications were noted. No procedural complications occurred and good aneurysm sealing was obtained in all patients. Three endoleaks were identified after 3 months (one patient) and 6 months (two patients); all were treated successfully with insertion of an additional stent-graft. In patients with DTAAs who are candidates for EVAR but have short aneurysm distal necks, celiac trunk embolization-only if the superior and inferior mesenteric arteries are patent-is a good and safe way to elongate the neck and enable EVAR.

  13. Can Surgeons Assess CT Suitability for Endovascular Repair (EVAR) in Ruptured Abdominal Aortic Aneurysm? Implications for a Ruptured EVAR Trial

    International Nuclear Information System (INIS)

    Rayt, Harjeet; Lambert, Kelly; Bown, Matthew; Fishwick, Guy; Morgan, Robert; McCarthy, Mark; London, Nick; Sayers, Robert

    2008-01-01

    The purpose of this study was to determine whether surgeons without formal radiological training are able to assess suitability of patients with ruptured abdominal aortic aneurysms (AAA) for EVAR. The CT scans of 20 patients with AAA were reviewed under timed conditions by six vascular surgeons. Twenty minutes was allocated per scan. They were asked to determine if each aneurysm would be treatable by EVAR in the emergency setting and, if so, to measure for device selection. The results were then compared with those of a vascular radiologist. Six surgeons agreed on the suitability of endovascular repair in 45% of cases (95% CI, 23.1-68.5%; 9/20 scans; κ = 0.41 [p = 0.01]) and concurred with the radiologist in eight of these. Individually, agreement ranged from 13 to 16 of the 20 scans, 65-80% between surgeons. The kappa value for agreement between all the surgeons and the radiologist was 0.47 (p = 0.01, moderate agreement). For the individual surgeons, this ranged from 0.3 to 0.6 (p = 0.01). In conclusion, while overall agreement was moderate between the surgeons and the radiologist, it is clear that if surgeons are to assess patients for ruptured EVAR in the future, focused training of surgical trainees is required.

  14. Intra-Abdominal Hypertension and Abdominal Compartment Syndrome in Association with Ruptured Abdominal Aortic Aneurysm in the Endovascular Era: Vigilance Remains Critical

    Directory of Open Access Journals (Sweden)

    Matthew C. Bozeman

    2012-01-01

    In this review, we describe published experience with IAH and ACS complicating abdominal vascular catastrophes, experience with ACS complicating endovascular repair of rAAAs, and techniques for management of the abdominal wound. Vigilance and appropriate management of IAH and ACS remains critically important in decreasing morbidity and optimizing survival following catastrophic intra-abdominal vascular events.

  15. Intra-abdominal hypertension and abdominal compartment syndrome in association with ruptured abdominal aortic aneurysm in the endovascular era: vigilance remains critical.

    Science.gov (United States)

    Bozeman, Matthew C; Ross, Charles B

    2012-01-01

    Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are common complications of ruptured abdominal aortoiliac aneurysms (rAAAs) and other abdominal vascular catastrophes even in the age of endovascular therapy. Morbidity and mortality due to systemic inflammatory response syndrome (SIRS) and multiple organ failure (MOF) are significant. Recognition and management of IAH are key critical care measures which may decrease morbidity and improve survival in these vascular patients. Two strategies have been utilized: expectant management with prompt decompressive laparotomy upon diagnosis of threshold levels of IAH versus prophylactic, delayed abdominal closure based upon clinical parameters at the time of initial repair. Competent management of the abdominal wound with preservation of abdominal domain is also an important component of the care of these patients. In this review, we describe published experience with IAH and ACS complicating abdominal vascular catastrophes, experience with ACS complicating endovascular repair of rAAAs, and techniques for management of the abdominal wound. Vigilance and appropriate management of IAH and ACS remains critically important in decreasing morbidity and optimizing survival following catastrophic intra-abdominal vascular events.

  16. Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

    Energy Technology Data Exchange (ETDEWEB)

    Chen, I-Ming [National Yang Ming University, Institute of Clinical Medicine, School of Medicine (China); Chen, Po-Lin; Huang, Chun-Yang [National Yang Ming University, Department of Medicine, School of Medicine (China); Weng, Shih-Hsien; Chen, Wei-Yuan; Shih, Chun-Che, E-mail: ccshih@vghtpe.gov.tw [National Yang Ming University, Institute of Clinical Medicine, School of Medicine (China)

    2017-05-15

    PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

  17. Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

    International Nuclear Information System (INIS)

    Chen, I-Ming; Chen, Po-Lin; Huang, Chun-Yang; Weng, Shih-Hsien; Chen, Wei-Yuan; Shih, Chun-Che

    2017-01-01

    PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

  18. Endovascular treatment of false-aneurysm ten years after dacron patch aortoplasty for coarctation of the aortic isthmus. Report of a case.

    Science.gov (United States)

    Illuminati, Giulio; Pacilè, Maria Antonietta; Palumbo, Piergaspare; Salvatori, Filippo Maria; Vietri, Francesco

    2013-01-01

    False aneurysm degeneration is a known complication of patch aortoplasty for coarctation of the aortic isthmus. Open surgical treatment consists of prosthetic graft repair of the involved aorta, often requires circulatory arrest to achieve a safe proximal aortic control and perform proximal anastomosis, and finally is associated with substantial perioperative morbidity. Endografting of the diseased aorta is a valuable alternative to open repair, when feasible, with good short and long term results. We now report one more case of false aneurysm ten years after Dacron patch aortoplasty for isthmic coarctation in a 26-year-old woman, successfully treated by endovascular repair via the left common iliac artery, and a complete exclusion of the aneurysm at two year follow-up.

  19. Endovascular Aneurysm Repair: Is Imaging Surveillance Robust, and Does It Influence Long-term Mortality?

    Energy Technology Data Exchange (ETDEWEB)

    Waduud, Mohammed Abdul, E-mail: m.a.waduud@doctors.org.uk [Glasgow Royal Infirmary, Department of Surgery (United Kingdom); Choong, Wen Ling, E-mail: wenlingchoong@nhs.net [Aberdeen Royal Infirmary, NHS Grampian, Department of Surgery (United Kingdom); Ritchie, Moira, E-mail: moirasim9@gmail.com; Williams, Claire, E-mail: c.williams.3@research.gla.ac.uk [University of Glasgow, Institute of Health and Wellbeing Glasgow (United Kingdom); Yadavali, Reddi, E-mail: reddi.yadavali@nhs.net [Aberdeen Royal Infirmary, NHS Grampian, Department of Radiology (United Kingdom); Lim, Shueh, E-mail: s.lim.06@aberdeen.ac.uk [Royal Infirmary of Edinburgh, NHS Lothian, Department of Radiology (United Kingdom); Buchanan, Fraser, E-mail: f.buchanan.11@aberdeen.ac.uk [University of Aberdeen, The School of Medicine and Dentistry (United Kingdom); Bhat, Raj, E-mail: raj.bhat@nhs.net [Ninewells Hospital, NHS Tayside, Department of Radiology (United Kingdom); Ramanathan, Krishnappan, E-mail: k.ramanathan@dundee.ac.uk [University of Dundee, School of Medicine (United Kingdom); Ingram, Susan, E-mail: susan.ingram@luht.scot.nhs.uk; Cormack, Laura, E-mail: lgcormack@googlemail.com [Royal Infirmary of Edinburgh, NHS Lothian, Department of Radiology (United Kingdom); Moss, Jonathan G., E-mail: jon.moss@ggc.scot.nhs.uk [Gartnavel General Hospital, Department of Radiology (United Kingdom)

    2015-02-15

    PurposeEndovascular aneurysm repair (EVAR) is the dominant treatment strategy for abdominal aortic aneurysms. However, as a result of uncertainty regarding long-term durability, an ongoing imaging surveillance program is required. The aim of the study was to assess EVAR surveillance in Scotland and its effect on all-cause and aneurysm-related mortality.MethodsA retrospective analysis of all EVAR procedures carried out in the four main Scottish vascular units. The primary outcome measure was the implementation of post-EVAR imaging surveillance across Scotland. Patients were identified locally and then categorized as having complete, incomplete, or no surveillance. Secondary outcome measures were all-cause mortality and aneurysm-related mortality. Cause of death was obtained from death certificates.ResultsData were available for 569 patients from the years 2001 to 2012. All centers had data for a minimum of 5 contiguous years. Surveillance ranged from 1.66 to 4.55 years (median 3.03 years). Overall, 53 % had complete imaging surveillance, 43 % incomplete, and 4 % none. For the whole cohort, all-cause 5-year mortality was 33.5 % (95 % confidence interval 28.0–38.6) and aneurysm-related mortality was 4.5 % (.8–7.3). All-cause mortality in patients with complete, incomplete, and no imaging was 49.9 % (39.2–58.6), 19.1 % (12.6–25.2), and 47.2 % (17.7–66.2), respectively. Aneurysm-related mortality was 3.7 % (1.8–7.4), 4.4 % (2.2–8.9), and 9.5 % (2.5–33.0), respectively. All-cause mortality was significantly higher in patients with complete compared to incomplete imaging surveillance (p < 0.001). No significant differences were observed in aneurysm-related mortality (p = 0.2).ConclusionOnly half of EVAR patients underwent complete long-term imaging surveillance. However, incomplete imaging could not be linked to any increase in mortality. Further work is required to establish the role and deliverability of EVAR imaging surveillance.

  20. Alginate oligosaccharide indirectly affects toll-like receptor signaling via the inhibition of microRNA-29b in aneurysm patients after endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Yang Y

    2017-09-01

    Full Text Available Yong Yang,1–4,* Zhenhuan Ma,1–4,* Guokai Yang,1–4 Jia Wan,1–4 Guojian Li,1–4 Lingjuan Du,1–4 Ping Lu1–4 1Department of Vascular Surgery, The Second People’s Hospital of Yunnan Province, Kunming, China; 2Department of Vascular Surgery, The Fourth Affiliated Hospital of Kunming Medical University, Kunming, China; 3Department of Vascular Surgery, Vascular Surgery Centre in Yunnan Province, Kunming, China; 4Department of Vascular Surgery, Abdominal Surgery Centre in Yunnan Province, Kunming, China *These authors contributed equally to this work Abstract: Endovascular aortic repair (EVAR is often followed by aneurysm recurrence. Alginate oligosaccharide (AOS has potential antitumor properties as a natural product while the related mechanisms remain unclear. Toll-like receptor (TLR signaling is associated with inflammatory activity of aneurysm and may be affected by miR-29b. Thus, inhibitory function of AOS on aneurysms was explored by measuring the important molecules in TLR4 signaling. After EVAR, a total of 248 aortic aneurysm patients were recruited and randomly assigned into two groups: AOS group (AG, oral administration 10-mg AOS daily and control group (CG, placebo daily. The size of residual aneurysms, aneurysm recurrence, and side effects were investigated. Aneurysm recurrence was determined by Kaplan–Meier analysis. After 2 years, eight and two patients died in the CG and AG, respectively. The sizes of residual aneurysms were significantly larger in the CG than in the AG (P<0.05. The incidence of aneurysm recurrence was also significantly higher in the CG than in the AG (P<0.05. AOS treatment reduced the levels of miR-29b, TLR4, mitogen-activated protein kinase (MAPK, nuclear factor kappa B (NF-kappa B, interleukin 1 (IL-1 beta, and interleukin 6 (IL-6. Overexpression and silence of miR-29b increased and reduced the level of TLR4, phospho-p65 NF-kappa B, phospho-p38 MAPK, IL-1 beta, and IL-6. Spearman’s rank correlation

  1. Low baseline and subsequent higher aortic abdominal aneurysm FDG uptake are associated with poor sac shrinkage post endovascular repair

    Energy Technology Data Exchange (ETDEWEB)

    Marie, Pierre-Yves [CHRU-Nancy, Universite de Lorraine, Nuclear Medecine and Nancyclotep Platform, Nancy (France); INSERM, University of Lorraine, UMR 1116, Nancy (France); CHRU-Nancy, Hopitaux de BRABOIS, Service de Medecine Nucleaire, Vandoeuvre (France); Plissonnier, Didier; Rouer, Martin [CHU-Rouen, Department of Vascular Surgery, Rouen (France); Bravetti, Stephanie [CHRU-Nancy, Universite de Lorraine, Department of Radiology, Nancy (France); Coscas, Raphael [Hopital Ambroise Pare, APHP, Chirurgie Vasculaire, Boulogne-Billancourt (France); Haulon, Stephan [CHU-Lille, Department of Vascular Surgery, Lille (France); Mandry, Damien [CHRU-Nancy, Universite de Lorraine, Department of Radiology, Nancy (France); INSERM, University of Lorraine, UMR 947, Nancy (France); Alsac, Jean-Marc [grid.414093.b, APHP, HEGP, Department of Vascular Surgery, Paris (France); Malikov, Serguei; Settembre, Nicla [CHRU-Nancy, Universite de Lorraine, Vascular Surgery, Nancy (France); Goueffic, Yann [CHU-Nantes, Department of Vascular Surgery, Nantes (France); Morel, Olivier [CHU-Besancon, Department of Nuclear Medecine, Besancon (France); Roch, Veronique [CHRU-Nancy, Universite de Lorraine, Nuclear Medecine and Nancyclotep Platform, Nancy (France); Micard, Emilien [INSERM, University of Lorraine, UMR 947, Nancy (France); INSERM, CHRU-Nancy, Universite de Lorraine, CIC-1433, FCRIN INI-CRCT, Nancy (France); Lamiral, Zohra [INSERM, CHRU-Nancy, Universite de Lorraine, CIC-1433, FCRIN INI-CRCT, Nancy (France); Michel, Jean-Baptiste [INSERM, Bichat, UMR 698, Paris (France); Rossignol, Patrick [INSERM, University of Lorraine, UMR 1116, Nancy (France); INSERM, CHRU-Nancy, Universite de Lorraine, CIC-1433, FCRIN INI-CRCT, Nancy (France)

    2018-04-15

    The growth phases of medically treated abdominal aortic aneurysms (AAA) are frequently associated with an {sup 18}F-fluorodesoxyglucose positron emission tomography (FDG-PET) pattern involving low baseline and subsequent higher FDG uptake. However, the FDG-PET patterns associated with the endovascular aneurysm repair (EVAR) of larger AAA are presently unknown. This study aimed to investigate the relationship between serial AAA FDG uptake measurements, obtained before EVAR and 1 and 6 months post-intervention and subsequent sac shrinkage at 6 months, a well-recognized indicator of successful repair. Thirty-three AAA patients referred for EVAR (maximal diameter: 55.4 ± 6.0 mm, total volume: 205.7 ± 63.0 mL) underwent FDG-PET/computed tomography (CT) before EVAR and at 1 and 6 months thereafter, with the monitoring of AAA volume and of a maximal standardized FDG uptake [SUVmax] averaged between the axial slices encompassing the AAA. Sac shrinkage was highly variable and could be stratified into three terciles: a first tercile in which shrinkage was absent or very limited (0-29 mL) and a third tercile with pronounced shrinkage (56-165 mL). SUVmax values were relatively low at baseline in the 1st tercile (SUVmax: 1.69 ± 0.33), but markedly increased at 6 months (2.42 ± 0.69, p = 0.02 vs. baseline). These SUV max values were by contrast much higher at baseline in the 3rd tercile (SUVmax: 2.53 ± 0.83 p = 0.009 vs. 1st tercile) and stable at 6 months (2.49 ± 0.80), while intermediate results were documented in the 2nd tercile. Lastly, the amount of sac shrinkage, expressed in absolute values or in percentages of baseline AAA volumes, was positively correlated with baseline SUVmax (p = 0.001 for both). A low pre-EVAR FDG uptake and increased AAA FDG uptake at 6 months are associated with reduced sac shrinkage. This sequential FDG-PET pattern is similar to that already shown to accompany growth phases of medically treated AAA. (orig.)

  2. Low baseline and subsequent higher aortic abdominal aneurysm FDG uptake are associated with poor sac shrinkage post endovascular repair

    International Nuclear Information System (INIS)

    Marie, Pierre-Yves; Plissonnier, Didier; Rouer, Martin; Bravetti, Stephanie; Coscas, Raphael; Haulon, Stephan; Mandry, Damien; Alsac, Jean-Marc; Malikov, Serguei; Settembre, Nicla; Goueffic, Yann; Morel, Olivier; Roch, Veronique; Micard, Emilien; Lamiral, Zohra; Michel, Jean-Baptiste; Rossignol, Patrick

    2018-01-01

    The growth phases of medically treated abdominal aortic aneurysms (AAA) are frequently associated with an 18 F-fluorodesoxyglucose positron emission tomography (FDG-PET) pattern involving low baseline and subsequent higher FDG uptake. However, the FDG-PET patterns associated with the endovascular aneurysm repair (EVAR) of larger AAA are presently unknown. This study aimed to investigate the relationship between serial AAA FDG uptake measurements, obtained before EVAR and 1 and 6 months post-intervention and subsequent sac shrinkage at 6 months, a well-recognized indicator of successful repair. Thirty-three AAA patients referred for EVAR (maximal diameter: 55.4 ± 6.0 mm, total volume: 205.7 ± 63.0 mL) underwent FDG-PET/computed tomography (CT) before EVAR and at 1 and 6 months thereafter, with the monitoring of AAA volume and of a maximal standardized FDG uptake [SUVmax] averaged between the axial slices encompassing the AAA. Sac shrinkage was highly variable and could be stratified into three terciles: a first tercile in which shrinkage was absent or very limited (0-29 mL) and a third tercile with pronounced shrinkage (56-165 mL). SUVmax values were relatively low at baseline in the 1st tercile (SUVmax: 1.69 ± 0.33), but markedly increased at 6 months (2.42 ± 0.69, p = 0.02 vs. baseline). These SUV max values were by contrast much higher at baseline in the 3rd tercile (SUVmax: 2.53 ± 0.83 p = 0.009 vs. 1st tercile) and stable at 6 months (2.49 ± 0.80), while intermediate results were documented in the 2nd tercile. Lastly, the amount of sac shrinkage, expressed in absolute values or in percentages of baseline AAA volumes, was positively correlated with baseline SUVmax (p = 0.001 for both). A low pre-EVAR FDG uptake and increased AAA FDG uptake at 6 months are associated with reduced sac shrinkage. This sequential FDG-PET pattern is similar to that already shown to accompany growth phases of medically treated AAA. (orig.)

  3. Outcomes of endovascular management of acute thoracic aortic emergencies in an academic level 1 trauma center.

    Science.gov (United States)

    Echeverria, Angela B; Branco, Bernardino C; Goshima, Kay R; Hughes, John D; Mills, Joseph L

    2014-12-01

    Thoracic aortic emergencies account for 10% of thoracic-related admissions in the United States and remain associated with high morbidity and mortality rates. Open repair has declined owing to the emergence of thoracic endovascular aortic repair (TEVAR), but data on emergency TEVAR use for acute aortic pathology remain limited. We therefore reviewed our experience. We retrospectively evaluated emergency descending thoracic aortic endovascular interventions performed at a single academic level 1 trauma center between January 2005 and August 2013 including all cases of traumatic aortic injury, ruptured descending thoracic aneurysm, penetrating atherosclerotic ulcer, aortoenteric fistula, and acute complicated type B dissection. Demographics, clinical data, and outcomes were extracted. Stepwise logistic regression was used to identify independent risk factors for death. During the study period, 51 patients underwent TEVAR; 22 cases (43.1%) were performed emergently (11 patients [50.0%] traumatic aortic injury; 4 [18.2%] ruptured descending thoracic aneurysm; 4 [18.2%] complicated type B dissection; 2 [9.1%] penetrating aortic ulcer; and 1 [4.5%] aortoenteric fistula). Overall, 72.7% (n = 16) were male with a mean age of 54.8 ± 15.9 years. Nineteen patients (86.4%) required only a single TEVAR procedure, whereas 2 (9.1%) required additional endovascular therapy, and 1 (4.5%) open thoracotomy. Four traumatic aortic injury patients required exploratory laparotomy for concomitant intra-abdominal injuries. During a mean hospital length of stay of 18.9 days (range, 1 to 76 days), 3 patients (13.6%) developed major complications. In-hospital mortality was 27.2%, consisting of 6 deaths from traumatic brain injury (1); exsanguination in the operating room before repair could be achieved (2); bowel ischemia (1) and multisystem organ failure (1); and family withdrawal of care (1). A stepwise logistic regression model identified 24-hour packed red blood cell requirements ≥4

  4. Clinical study of bilateral decompression via vertebral lamina fenestration for lumbar interbody fusion in the treatment of lower lumbar instability

    OpenAIRE

    GUO, SHUGUANG; SUN, JUNYING; TANG, GENLIN

    2013-01-01

    The aim of this study was to observe the clinical effects of bilateral decompression via vertebral lamina fenestration for lumbar interbody fusion in the treatment of lower lumbar instability. The 48 patients comprised 27 males and 21 females, aged 47?72 years. Three cases had first and second degree lumbar spondylolisthesis and all received bilateral vertebral lamina fenestration for posterior lumbar interbody fusion (PLIF) using a threaded fusion cage (TFC), which maintains the three-column...

  5. Advanced fenestration and daylighting systems

    Energy Technology Data Exchange (ETDEWEB)

    McCluney, R. [Florida Solar Energy Centere, Cocoa, FL (United States)

    1998-09-01

    Advanced fenestration systems are new high-performance glazing and reflecting systems for otherwise conventional windows which offer specialized spectral and /or angular selectivity to provide improved illumination quantity and quality under optimal human comfort and energy conservation conditions. Advanced daylighting systems include systems manufactured by the solar lighting industry to introduce daylight into the core spaces of multi-storey buildings, spaces distant from the building envelope, or other locations where more conventional daylighting apertures cannot be placed. Details of operating, energy and illumination performance characteristics of both these systems were provided. It was concluded that solar lighting systems can effectively provide daylight illumination to interior spaces of a building that are not amenable to more conventional systems. Nevertheless, techniques need to be developed to predict the performance of such systems prior to their being built, so as to provide designers better means for justifying their use and economic viability, and to develop codes and performance standards to protect the consumer in the marketplace. 20 refs., 12 figs.

  6. Carotid and coronary disease management prior to open and endovascular aortic surgery. What are the current guidelines?

    Science.gov (United States)

    Thompson, J P

    2014-04-01

    Several bodies produce broadly concurring and updated guidelines for the evaluation and treatment of cardiovascular disease in both surgical and non-surgical patients. Recent developments include revised recommendations on preoperative stress testing, referral for possible coronary revascularization and medical management. It is recognized that non-invasive cardiac tests are relatively poor at predicting perioperative risk, and "prophylactic" coronary revascularization has a limited role. The planned aortic intervention (open or endovascular repair) also influences preoperative management. Patients presenting for elective abdominal aortic aneurysm (AAA) repair should only be referred for cardiological testing if they have active symptoms of coronary artery disease (CAD), known CAD and poor functional exercise capacity, or multiple risk factors for CAD. Coronary revascularization before AAA surgery should be limited to patients with established indications, so cardiac stress testing should only be performed if it would change management i.e. the patient is a candidate for and would benefit from coronary revascularization. When endovascular aortic repair is planned, it is reasonable to proceed to surgery without further cardiac stress testing or evaluation unless otherwise indicated. All non-emergency patients require medical optimization, but perioperative beta blockade benefits only certain patients. Some of the data informing recent guidelines have been questioned and some guidelines are being revised. Current guidelines do not specifically address the management of patients with known or suspected carotid artery disease who may require aortic surgery. For these patients, an individualized approach is required. This review considers recent guidelines. Algorithms for investigation and management based on their recommendations are included.

  7. Endovascular repair of renal artery aneurysm with the multilayer stent – a short report

    Directory of Open Access Journals (Sweden)

    Vojko Flis

    2012-10-01

    in the main left renal artery involving all three major branches of the renal artery. Via a percutaneous femoral approach a multilayer stent was deployed without complications. Blood flow inside the sac was immediately and significantly reduced. All the renal branches remained patent. Conclusion: New multilayer fluid modulating stent concept appears to be a very useful and attractive alternative to surgery or other endovascular techniques for those RAA involving or very close to major branch vessels, especially in patients with very high risk of loosing the only viable kidney, as in our case.

  8. Advances in endovascular aneurysm treatment: are we making a difference?

    International Nuclear Information System (INIS)

    Katz, Jeffrey M.; Ougorets, Igor; Tsiouris, Apostolos J.; Biondi, Alessandra; Salvaggio, Kimberly A.; Gobin, Y. Pierre; Stieg, Philip E.; Riina, Howard A.

    2005-01-01

    Recent advancements in endovascular aneurysm repair, including bioactive and expansile coils and intracranial stents, hold promise for improved aneurysm occlusion rates. We report the immediate and midterm clinical and angiographic outcomes of a consecutive series of patients treated since the advent of these technologies. Clinical and radiological records of 134 patients with 142 aneurysms treated between 2001 and 2004 were retrospectively evaluated by an independent neurologist. Endovascular procedures were analyzed by an independent neuroradiologist blinded to all clinical information. Seventy-two ruptured and 60 un-ruptured saccular aneurysms, nine fusiform and one post-traumatic aneurysm were treated. Matrix coils were used in 53% of saccular aneurysms and HydroCoils in 13% of all aneurysms. Neuroform stents were deployed in 19% of aneurysms. Angiographic total or subtotal occlusion was achieved in 76% of cases and in 96% at last follow-up. Aneurysm recanalization was observed in 14% over a mean follow-up of 12 months, and 18% of aneurysms were retreated. Clinically relevant complications occurred in 6.0%, resulting in procedure-related morbidity of 0.6% and 0.6% mortality at 6 months. No aneurysm bled over a cumulative 1,347 months of observation. Newer embolization technologies can be exploited successfully even in more complex aneurysms with very low morbidity and mortality. (orig.)

  9. Early inflammatory response following elective abdominal aortic aneurysm repair: A comparison between endovascular procedure and conventional, open surgery

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2011-01-01

    Full Text Available Background/Aim. Abdominal aorta aneurysm (AAA represents a pathological enlargment of infrarenal portion of aorta for over 50% of its lumen. The only treatment of AAA is a surgical reconstruction of the affected segment. Until the late XX century, surgical reconstruction implied explicit, open repair (OR of AAA, which was accompanied by a significant morbidity and mortality of the treated patients. Development of endovascular repair of (EVAR AAA, especially in the last decade, offered another possibility of surgical reconstruction of AAA. The preliminary results of world studies show that complications of such a procedure, as well as morbidity and mortality of patients, are significantly lower than with OR of AAA. The aim of this paper was to present results of comparative clinical prospective study of early inflammatory response after reconstruction of AAA between endovascular and open, conventional surgical technique. Methods. A comparative clinical prospective study included 39 patients, electively operated on for AAA within the period of December 2008 - February 2010, divided into two groups. The group I counted 21 (54% of the patients, 58-87 years old (mean 74.3 years, who had been submited to EVAR by the use of excluder stent graft. The group II consisted of 18 (46% of the patients, 49-82 (mean 66.8 years, operated on using OR technique. All of the treated patients in both groups had AAA larager than 50 mm. The study did not include patients who have been treated as urgent cases, due to the rupture or with simptomatic AAA. Clinical, biochemical and inflamatory parameters in early postoperative period were analyzed, in direct postoperative course (number of leucocytes, thrombocytes, serum circulating levels of cytokine - interleukine (IL-2, IL-4, IL-6 and IL-10. Parameters were monitored on the zero, first, second, third and seventh postoperative days. The study was approved by the Ethics Commitee of the Military Medical Academy. Results

  10. Platelet-Rich Plasma Injection With Percutaneous Needling for Recalcitrant Lateral Epicondylitis: Comparison of Tenotomy and Fenestration Techniques.

    Science.gov (United States)

    Gaspar, Michael P; Motto, Michael A; Lewis, Sarah; Jacoby, Sidney M; Culp, Randall W; Lee Osterman, A; Kane, Patrick M

    2017-12-01

    Recalcitrant lateral epicondylitis (LE) is a common debilitating condition, with numerous treatment options of varying success. An injection of platelet-rich plasma (PRP) has been shown to improve LE, although it is unclear whether the method of needling used in conjunction with a PRP injection is of clinical importance. To determine whether percutaneous needle tenotomy is superior to percutaneous needle fenestration when each is combined with a PRP injection for the treatment of recalcitrant LE. Cohort study; Level of evidence, 3. A total of 93 patients with recalcitrant LE were treated with a PRP injection and percutaneous needle fenestration (n = 45) or percutaneous needle tenotomy (n = 48) over a 5-year study interval. Preoperative patient data, including visual analog scale for pain (VAS-P), Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH), and Patient-Rated Tennis Elbow Evaluation (PRTEE) scores and grip strength, were obtained from a chart review and compared with postoperative values obtained prospectively. Secondary outcomes included the incidence of complications, need for additional interventions, return to work, and patient satisfaction. At a mean follow-up of 40 months, significant improvements in VAS-P (mean, -6.1; 95% CI, -6.8 to -5.5; P < .0001), QuickDASH (mean, -46; 95% CI, -52 to -40; P < .0001), and PRTEE (mean, -57; 95% CI, -64 to -50; P < .0001) scores and grip strength (mean, +6.1 kg; 95% CI, 4.9 to 7.3; P < .0001) were observed across the entire study cohort, with no significant differences noted between the fenestration and tenotomy groups. Nine of 45 patients (22%) underwent additional procedures to treat recurrent symptoms in the fenestration group compared with 5 of 48 patients (10%) in the tenotomy group ( P = .05). No complications occurred in any patients, and no patients expressed dissatisfaction with their treatment course. A PRP injection with concomitant percutaneous needling is an effective treatment for recalcitrant

  11. Endovascular treatment of PICA aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mukonoweshuro, W.; Laitt, R.D.; Hughes, D.G. [Radiology Dept., Greater Manchester Neurosciences Unit, Hope Hospital, Salford, Manchester (United Kingdom)

    2003-03-01

    Endovascular treatment of aneurysms of the posterior inferior cerebellar artery (PICA) avoids manipulation of the brainstem or lower cranial nerves and should therefore carry a lower risk of neurological morbidity than surgical clipping. We reviewed our experience of 23 patients with PICA aneurysms treated by endovascular occlusion with Guglielmi detachable coils and documented their long-term outcome on follow-up. We observed a 28 day procedure-related neurological morbidity of 13% (3/23 patients). One patient suffered permanent neurological complications. There were no procedure-related deaths. None of our patients suffered a re-bleed from their treated aneurysms. Our series shows endovascular treatment of ruptured PICA aneurysms to be safe and effective. (orig.)

  12. Endovascular approach to treat ascending aortic pseudoaneurysm in a patient with previous CABG and very high surgical risk.

    Science.gov (United States)

    Zago, Alexandre C; Saadi, Eduardo K; Zago, Alcides J

    2011-10-01

    Pseudoaneurysm of the ascending aorta is an uncommon pathology and a challenge in high-risk patients who undergo conventional surgery because of high operative morbidity and mortality. Endovascular exclusion of an aortic pseudoaneurysm using an endoprosthesis is a less invasive approach, but few such cases have been reported. Moreover, the use of this approach poses unique therapeutic challenges because there is no specific endoprosthesis for ascending aortic repair, particularly to treat patients with previous coronary artery bypass graft (CABG). We describe the case of a 74-year-old patient who had undergone CABG and later presented with an iatrogenic ascending aortic pseudoaneurysm that occurred during an angiography. This patient was at very high risk for surgical treatment and, therefore, an endovascular approach was adopted: percutaneous coronary intervention for the left main coronary artery, left anterior descending and left circumflex native coronary arteries followed by endovascular endoprosthesis deployment in the ascending aorta to exclude the pseudoaneurysm. Both procedures were successfully performed, and the patient was discharged without complications 4 days later. At 5 months' clinical follow-up, his clinical condition was good and he had no complications. Copyright © 2011 Wiley-Liss, Inc.

  13. Small GTP-Binding Protein Rac Is an Essential Mediator of Vascular Endothelial Growth Factor-Induced Endothelial Fenestrations and Vascular Permeability

    DEFF Research Database (Denmark)

    Eriksson, A.; Cao, R.; Tritsaris, K.

    2003-01-01

    fenestrated endothelium, a feature linked with increased vascular permeability. A cell-permeable Rac antagonist (TAT-RacN17) converted VEGF-induced, leaky vascular plexuses into well-defined vascular networks. In addition, this Rac mutant blocked formation of VEGF-induced endothelial fenestrations...... in mediation of VEGF-induced vascular permeability but less so in neovascularization. This may have conceptual implications for applying Rac antagonists in treatment and prevention of VEGF-induced vascular leakage and edema in connection with ischemic disorders....

  14. ORIGINAL ARTICLES Endovascular treatment of cerebral ...

    African Journals Online (AJOL)

    With this in mind we looked at the costs ... of surgical or endovascular disposables. ... surgical versus endovascular treatment were 18 and 6 days .... 329: 527) gives a list of nine risk factors which explain most heart attacks: an abnormal ratio.

  15. Endovascular management of delayed post-pancreatectomy haemorrhage

    International Nuclear Information System (INIS)

    Pottier, Edwige; Ronot, Maxime; Vilgrain, Valerie; Gaujoux, Sebastien; Cesaretti, Manuela; Barbier, Louise; Sauvanet, Alain

    2016-01-01

    To assess the patient outcome after endovascular treatment of delayed post-pancreatectomy haemorrhage (PPH) as first-line treatment. Between January 2005 and November 2013, all consecutive patients referred for endovascular treatment of PPH were included. Active bleeding, pseudoaneurysms, collections and the involved artery were recorded on pretreatment CT. Endovascular procedures were classified as technical success (source of bleeding identified on angiogram and treated), technical failure (source of bleeding identified but incompletely treated) and abstention (no abnormality identified, no treatment performed). Factors associated with rebleeding were analysed. Sixty-nine patients (53 men) were included (mean 59 years old (32-75)). Pretreatment CT showed 27 (39 %) active bleeding. In 22 (32 %) cases, no involved artery was identified. Technical success, failure and abstention were observed in 48 (70 %), 9 (13 %) and 12 patients (17 %), respectively. Thirty patients (43 %) experienced rebleeding. Rebleeding rates were 29 %, 58 % and 100 % in case of success, abstention and failure (p < 0.001). Treatment failure/abstention was the only factor associated with rebleeding. Overall, 74 % of the patients were successfully treated by endovascular procedure(s) alone. After a first endovascular procedure for PPH, the rebleeding rate is high and depends upon the success of the procedure. Most patients are successfully treated by endovascular approach(es) alone. (orig.)

  16. Endovascular management of delayed post-pancreatectomy haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Pottier, Edwige [Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); Ronot, Maxime; Vilgrain, Valerie [Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); University Paris Diderot, Paris (France); INSERM U1149, centre de recherche biomedicale Bichat-Beaujon, CRB3, Paris (France); Gaujoux, Sebastien; Cesaretti, Manuela; Barbier, Louise [APHP, University Hospitals Paris Nord Val de Seine, Beaujon, Department of Surgery, Clichy, Hauts-de-Seine (France); Sauvanet, Alain [University Paris Diderot, Paris (France); APHP, University Hospitals Paris Nord Val de Seine, Beaujon, Department of Surgery, Clichy, Hauts-de-Seine (France)

    2016-10-15

    To assess the patient outcome after endovascular treatment of delayed post-pancreatectomy haemorrhage (PPH) as first-line treatment. Between January 2005 and November 2013, all consecutive patients referred for endovascular treatment of PPH were included. Active bleeding, pseudoaneurysms, collections and the involved artery were recorded on pretreatment CT. Endovascular procedures were classified as technical success (source of bleeding identified on angiogram and treated), technical failure (source of bleeding identified but incompletely treated) and abstention (no abnormality identified, no treatment performed). Factors associated with rebleeding were analysed. Sixty-nine patients (53 men) were included (mean 59 years old (32-75)). Pretreatment CT showed 27 (39 %) active bleeding. In 22 (32 %) cases, no involved artery was identified. Technical success, failure and abstention were observed in 48 (70 %), 9 (13 %) and 12 patients (17 %), respectively. Thirty patients (43 %) experienced rebleeding. Rebleeding rates were 29 %, 58 % and 100 % in case of success, abstention and failure (p < 0.001). Treatment failure/abstention was the only factor associated with rebleeding. Overall, 74 % of the patients were successfully treated by endovascular procedure(s) alone. After a first endovascular procedure for PPH, the rebleeding rate is high and depends upon the success of the procedure. Most patients are successfully treated by endovascular approach(es) alone. (orig.)

  17. Outcomes and Prognostic Factors of Endovascular Abdominal Aortic Aneurysm Repair in Patients with Hostile Neck Anatomy

    International Nuclear Information System (INIS)

    Jung, Hye Doo; Lee, Yun Young; Lee, Seung Jin; Yim, Nam Yeol; Kim, Jae Kyu; Choi, Soo Jin Na; Jung, Sang Young; Chang, Nam Kyu; Lim, Jae Hoon

    2012-01-01

    To evaluate the outcomes and find the prognostic factors of endovascular abdominal aortic aneurysm repair (EVAR) in patients with hostile neck anatomy of the abdominal aorta. This study was performed on 100 patients with abdominal aneurysm who were treated with EVAR between March 2006 and December 2010. We divided the patients into two groups: good neck anatomy (GNA), and hostile neck anatomy (HNA) and then compared the primary success rate and the incidence rate of complications with EVAR between the two groups. Our aim was to determine the factors related to the complications of EVAR among HNA types. There were no significant differences of primary success rate and incidence rate of complications between the two groups. Among the types of HNA, the short neck angle [odd ratio (OR), 4.23; 95% confidence interval (CI), 1.21-18.70; p = 0.023] and large neck angle (OR, 2.58; 95% CI, 0.15-11.85; p = 0.031) showed a low primary success rate. The short neck angle (OR, 2.32; 95% CI, 1.18-12.29; p = 0.002) and large neck angle (OR, 4.67; 95% CI, 0.14-19.07; p = 0.032) showed a high incidence rate of early type 1 complication. In the case of the large neck angle (OR, 3.78; 95% CI, 0.96-20.80; p = 0.047), the large neck thrombus (OR, 2.23; 95% CI, 0.24-7.12; p = 0.035) and large neck calcification (OR, 2.50; 95% CI, 0.08-18.37; p 0.043) showed a high incidence rate of complications within a year. The results suggest that patients with hostile neck anatomy can be treated with EVAR successfully, although there was a higher incidence of complications in patients with a short neck length, severe neck angulation, circumferential thrombosis, and calcified proximal neck.

  18. Aortic aneurysm sac pressure measurements after endovascular repair using an implantable remote sensor: initial experience and short-term follow-up

    International Nuclear Information System (INIS)

    Hoppe, Hanno; Kaufman, John A.; Segall, Jocelyn A.; Liem, Timothy K.; Landry, Gregory J.

    2008-01-01

    The purpose of this single-center study was to report our initial experience with an implantable remote pressure sensor for aneurysm sac pressure measurement in patients post-endovascular aneurysm repair (EVAR) including short-term follow-up. A pressure sensor (EndoSure, Atlanta, GA) was implanted in 12 patients treated with different commercially available aortic endografts for EVAR. Pressure was read pre- and post-EVAR in the operating room. One-month follow-up (30 days ± 6 days) was performed including sac pressure readings and IV contrast CT scans. Variables were compared using the paired Student's t test. An intraprocedure type-I endoleak and a type-III endoleak were successfully treated resulting in decreasing sac pressures. In all patients, post-EVAR systolic sac pressure decreased by an average of 33% (P ≤ 0.005) compared to pre-EVAR measurements. One-month follow-up demonstrated a 47% decrease in systolic sac pressure (P ≤ 0.05). On follow-up CT scans, the average maximum aneurysm diameter pre-EVAR was 6.3 ± 1.6 cm and post-EVAR 6.0 ± 1.7 cm (P≤0.05). The diameter of the aneurysm sac was larger only in one patient with a type-III endoleak. Remote sac pressure measurement may provide important information in addition to imaging and may help to reduce the number of follow-up CT scans. (orig.)

  19. Successful endovascular treatment of a hemodialysis graft pseudoaneurysm by covered stent and direct percutaneous thrombin injection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2011-07-25

    Vascular access for hemodialysis remains a challenge for nephrologists, vascular surgeons, and interventional radiologists alike. Arteriovenous fistula and synthetic grafts remain the access of choice for long-term hemodialysis; however, they are subject to complications from infection and repeated needle cannulation. Pseudoaneurysms are an increasingly recognized adverse event. At present, there are many minimally invasive methods to repair these wall defects. We present a graft pseudoaneurysm, which required a combination of endovascular stent graft placement and percutaneous thrombin injection for successful occlusion.

  20. Effects of electrocautery to provoke endovascular thermal injury Efeitos do eletrocautério para provocar lesão térmica endovascular

    Directory of Open Access Journals (Sweden)

    Fabio Henrique Rossi

    2011-10-01

    Full Text Available PURPOSE: To investigate the effects of a new electrocautery device to provoke endovascular venous thermal injury. METHODS: An experimental endovascular electrocautery was placed inside eight ex-vivo bovine saphenous veins models. Each one was divided in eight segments and progressive intensities of electric energy liberated. The macroscopic and microscopic effects were analyzed. RESULTS: Forty bovine saphenous veins segments were studied. The higher the electric energy applied the greater the nuclear picnosis and more intense the cytoplasmatic shrinkage and electrocoagulation effects. CONCLUSION: The experimental endovascular electrocautery device demonstrated to be both capable of inducing the destruction of the intimal layers of the studied vein model and provoke endovascular thermal injury.OBJETIVO: Investigar os efeitos de um modelo experimental de eletrocautério em provocar lesão venosa térmica endovascular. MÉTODOS: O eletrocautério endovascular foi colocado dentro de oito modelos experimentais de veia safena bovina. Cada uma foi dividida em oito segmentos e intensidades progressivas de energia elétrica liberada. Os efeitos macroscópicos e microscópicos foram analisados. RESULTADOS: Foram estudados quarenta segmentos de veia safena bovina. Quanto maior a energia elétrica aplicada pelo eletrocauterizador endovascular maiores foram as alteraçoes de picnose nuclear e mais intensa a retração citoplasmática observada. CONCLUSÃO: O eletrocautério endovascular experimental demonstrou ser capaz de induzir a destruição da camada íntima e provocar lesão térmica endovascular.

  1. Efficacy and Safety of Augmenting the Preclose Technique with a Collagen-Based Closure Device for Percutaneous Endovascular Aneurysm Repair

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rafiuddin, E-mail: rafiuddin.patel@ouh.nhs.uk [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Juszczak, Maciej T. [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Bratby, Mark J. [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Sideso, Ediri [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Anthony, Susan; Tapping, Charles R. [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Handa, Ashok; Darby, Christopher R.; Perkins, Jeremy [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Uberoi, Raman [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom)

    2015-08-15

    PurposeTo report our experience of selectively augmenting the preclose technique for percutaneous endovascular aneurysm repair (p-EVAR) with an Angio-Seal device as a haemostatic adjunct in cases of significant bleeding after tensioning the sutures of the suture-mediated closure devices.Materials and MethodsProspectively collected data for p-EVAR patients at our institute were analysed. Outcomes included technical success and access site complications. A logistic regression model was used to analyse the effects of sheath size, CFA features and stent graft type on primary failure of the preclose technique necessitating augmentation and also on the development of complications.Resultsp-EVAR was attempted via 122 CFA access sites with a median sheath size of 18-French (range 12- to 28-French). Primary success of the preclose technique was 75.4 % (92/122). Angio-Seal augmentation was utilised as an adjunct to the preclose technique in 20.5 % (25/122). The overall p-EVAR success rate was 95.1 % (116/122). There was a statistically significant relationship (p = 0.0093) between depth of CFA and primary failure of preclose technique. CFA diameter, calcification, type of stent graft and sheath size did not have significant effects on primary preclose technique failure. Overall 4.9 % (6/122) required surgical conversion but otherwise there were no major complications.ConclusionAugmentation with an Angio-Seal device is a safe and effective adjunct to increase the success rate of the preclose technique in p-EVAR.

  2. Vascular training and endovascular practice in Europe

    DEFF Research Database (Denmark)

    Liapis, C.D.; Avgerinos, E.D.; Sillesen, H.

    2009-01-01

    specialties was distributed to a VS educator within 14 European countries. European Vascular and Endovascular Monitor (EVEM) data also were processed to correlate endovascular practice with training models. RESULTS: Fourteen questionnaires were gathered. Vascular training in Europe appears in 3 models: 1....... Mono-specialty (independence): 7 countries, 2. Subspecialty: 5 countries, 3. An existing specialty within general surgery: 2 countries. Independent compared to non-independent certification shortens overall training length (5.9 vs 7.9 years, p=0.006), while increasing overall training devoted......% respectively. Countries with independent vascular certification, despite their lower average endovascular index (procedures per 100,000 population), reported a higher growth rate of aortic endovascular procedures (VS independent 132% vs VS non-independent 87%), within a four-year period (2003-2007). Peripheral...

  3. Complications in Endovascular Neurosurgery: Critical Analysis and Classification.

    Science.gov (United States)

    Ravindra, Vijay M; Mazur, Marcus D; Park, Min S; Kilburg, Craig; Moran, Christopher J; Hardman, Rulon L; Couldwell, William T; Taussky, Philipp

    2016-11-01

    Precisely defining complications, which are used to measure overall quality, is necessary for critical review of delivery of care and quality improvement in endovascular neurosurgery, which lacks common definitions for complications. Furthermore, in endovascular interventions, events that may be labeled complications may not always negatively affect outcome. Our objective is to provide precise definitions for quality evaluation within endovascular neurosurgery. Thus, we propose an endovascular-specific classification system of complications based on our own patient series. This single-center review included all patients who had endovascular interventions from September 2013 to August 2015. Complication types were analyzed, and a descriptive analysis was undertaken to calculate the incidence of complications overall and in each category. Two hundred and seventy-five endovascular interventions were performed in 245 patients (65% female; mean age, 55 years). Forty complications occurred in 39 patients (15%), most commonly during treatment of intracranial aneurysms (24/40). Mechanical complications (eg, device deployment, catheter, or closure device failure) occurred in 8/40, technical complications (eg, failure to deploy flow diverter, unintended embolization, air emboli, retroperitoneal hemorrhage, dissection) in 11/40, judgment errors (eg, patient or equipment selection) in 9/40, and critical events (eg, groin hematoma, hemorrhagic or thromboembolic complications) in 12/40 patients. Only 12/40 complications (30%) resulted in new neurologic deficits, vessel injury requiring surgery, or blood transfusion. We propose an endovascular-specific classification system of complications with 4 categories: mechanical, technical, judgment errors, and critical events. This system provides a framework for future studies and quality control in endovascular neurosurgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Lower extremity weakness is associated with elevated blood and cerebrospinal fluid glucose levels following multibranched endovascular aortic aneurysm repair.

    Science.gov (United States)

    Hiramoto, Jade S; Fernandez, Charlene; Gasper, Warren; Vartanian, Shant; Reilly, Linda; Chuter, Timothy

    2017-02-01

    Hyperglycemia is associated with worsened clinical outcomes after central nervous system injury. The purpose of this study was to examine the association between lower extremity weakness (LEW) and the glucose levels of blood and cerebrospinal fluid (CSF) in patients undergoing multibranched endovascular aneurysm repair (MBEVAR) of thoracoabdominal and pararenal aortic aneurysms. Blood and CSF samples were collected preoperatively, immediately after aneurysm repair, and on postoperative day 1 in 21 patients undergoing MBEVAR. Data on demographics, operative repair, complications, and outcomes were collected prospectively. There were 21 patients who underwent successful MBEVAR. Two patients had pre-existing paraplegia from prior open aortic surgery and were excluded from the current analysis. The mean age was 73 ± 8 years, and 15 of 19 (79%) were men. In the postoperative period, 7 of 19 (37%) patients developed LEW. This was temporary in 5 of 19 (26%) patients and permanent in 2 of 19 (11%) patients. The LEW group was older than the non-LEW group (77 ± 6 vs 70 ± 9 years, respectively; P = .10), had a lower preoperative glomerular filtration rate (58.6 ± 18.5 vs 71.4 ± 23.5 mL/min per 1.73 m 2 ; P = .24), and was more likely to be taking a statin (100% vs 67%, respectively; P = .13), but these did not reach statistical significance. There was no significant difference in the prevalence of diabetes mellitus, hypertension, coronary artery disease, lung disease, or peripheral artery disease between the LEW and non-LEW groups. There was also no difference in operative time, blood loss, contrast material volume, or fluoroscopy times between the two groups. Preoperative blood and CSF glucose levels were similar in those with and without LEW. During the postoperative period, glucose values in the blood and CSF were significantly higher in those patients who developed LEW compared with those who did not develop LEW. In all patients with LEW, the elevation

  5. Daylighting and Cooling of Atrium Buildings in Warm Climates: Impact of the Top-Fenestration and Wall Mass Area.

    Science.gov (United States)

    Atif, Morad Rachid

    1992-01-01

    Sun-lighting and daylighting contribute greatly to the aesthetic value of an atrium. However, today's atria are often found either over-lit with extensive cooling loads, or under-lit requiring increased artificial lighting loads. The increase of the top-glazing area increases the cooling loads and decreases the lighting loads. The increase of the mass in the atrium walls decreases the maximum atrium temperature and the cooling loads. Furthermore, the mass distribution and its reflectance affect the lighting levels at the atrium floor. The purpose of this study is to investigate the simultaneous impact of the top-fenestration and the mass and reflectance of atrium walls on the cooling and daylighting performance of atria in warm climates. It attempts to determine the optimum top-fenestration for efficient daylighting and low cooling loads. The daylighting performance was evaluated through illumination measurements in physical models in a sky simulator. The cooling performance was evaluated using the software TRNSYS 13.1. Two types of top-fenestration were tested: horizontal and vertical south-facing, each with three alternate areas. The variations of the atrium walls included materials (standard frame and heavyweight concrete) and percentage and reflectance of the solid area. Two and four-story atria were considered, each with square and linear configuration. The performance was evaluated for three warm climates. The optimum top-fenestration for efficient daylighting was determined. The daylighting prediction algorithm was extended to include the effective reflectance of the atrium walls. The increase of mass in the atrium walls significantly decreased the atrium temperature range, the maximum atrium temperature, and the cooling loads. This impact decreased from horizontal to vertical south-facing top-glazing. The vertical south-facing top-glazing and, to a lesser degree, the reduction of the glazed atrium cover by 50% had more cooling benefits than increasing the

  6. Endovascular treatment of ruptured splenic artery aneurysm

    DEFF Research Database (Denmark)

    Bjerring, Ole Steen

    2008-01-01

    Splenic artery aneurysms (SAA) are traditionally treated surgically, but endovascular techniques are becoming increasingly popular. A 64 year-old male with chest pain and low blood pressure was admitted under suspicion of AMI. A CT scan showed a 56 mm SAA with signs of rupture. The patient...... was treated with endovascular embolisation of the SAA with coils. Blood pressure and haemoglobin levels were stabilized and the patient was discharged. In the case of rupture the treatment of choice seems to be endovascular....

  7. A multimodality vascular imaging phantom of an abdominal aortic aneurysm with a visible thrombus

    Energy Technology Data Exchange (ETDEWEB)

    Allard, Louise; Chayer, Boris; Qin Zhao [Laboratory of Biorheology and Medical Ultrasonics, Research Center, University of Montreal Hospital (CRCHUM), Quebec H2L 2W5 (Canada); Soulez, Gilles [Department of Radiology, University of Montreal Hospital (CHUM), Quebec H2L 2M1 (Canada); Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Quebec H3T 1J4 (Canada); Institute of Biomedical Engineering, University of Montreal, Quebec H3T 1J4 (Canada); Roy, David [Institute of Biomedical Engineering, University of Montreal, Quebec H3T 1J4 (Canada); Cloutier, Guy [Laboratory of Biorheology and Medical Ultrasonics, Research Center, University of Montreal Hospital (CRCHUM), Quebec H2L 2W5 (Canada); Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Quebec H3T 1J4 (Canada); Institute of Biomedical Engineering, University of Montreal, Quebec H3T 1J4 (Canada)

    2013-06-15

    Purpose: With the continuous development of new stent grafts and implantation techniques, it has now become technically feasible to treat abdominal aortic aneurysms (AAA) with challenging anatomy using endovascular repair with standard, fenestrated, or branched stent-grafts. In vitro experimentations are very useful to improve stent-graft design and conformability or imaging guidance for stent-graft delivery or follow-up. Vascular replicas also help to better understand the limitation of endovascular approaches in challenging anatomy and possibly improve surgical planning or training by practicing high risk clinical procedures in the laboratory to improve outcomes in the operating room. Most AAA phantoms available have a very basic anatomy, which is not representative of the clinical reality. This paper presents a method of fabrication of a realistic AAA phantom with a visible thrombus, as well as some mechanical properties characterizing such phantom. Methods: A realistic AAA geometry replica of a real patient anatomy taken from a multidetector computed tomography (CT) scan was manufactured. To demonstrate the multimodality imaging capability of this new phantom with a thrombus visible in magnetic resonance (MR) angiography, CT angiography (CTA), digital subtraction angiography (DSA), and ultrasound, image acquisitions with all these modalities were performed by using standard clinical protocols. Potential use of this phantom for stent deployment was also tested. A rheometer allowed defining hyperelastic and viscoelastic properties of phantom materials. Results: MR imaging measurements of SNR and CNR values on T1 and T2-weighted sequences and MR angiography indicated reasonable agreement with published values of AAA thrombus and abdominal components in vivo. X-ray absorption also lay within normal ranges of AAA patients and was representative of findings observed on CTA, fluoroscopy, and DSA. Ultrasound propagation speeds for developed materials were also in

  8. A multimodality vascular imaging phantom of an abdominal aortic aneurysm with a visible thrombus

    International Nuclear Information System (INIS)

    Allard, Louise; Chayer, Boris; Qin Zhao; Soulez, Gilles; Roy, David; Cloutier, Guy

    2013-01-01

    Purpose: With the continuous development of new stent grafts and implantation techniques, it has now become technically feasible to treat abdominal aortic aneurysms (AAA) with challenging anatomy using endovascular repair with standard, fenestrated, or branched stent-grafts. In vitro experimentations are very useful to improve stent-graft design and conformability or imaging guidance for stent-graft delivery or follow-up. Vascular replicas also help to better understand the limitation of endovascular approaches in challenging anatomy and possibly improve surgical planning or training by practicing high risk clinical procedures in the laboratory to improve outcomes in the operating room. Most AAA phantoms available have a very basic anatomy, which is not representative of the clinical reality. This paper presents a method of fabrication of a realistic AAA phantom with a visible thrombus, as well as some mechanical properties characterizing such phantom. Methods: A realistic AAA geometry replica of a real patient anatomy taken from a multidetector computed tomography (CT) scan was manufactured. To demonstrate the multimodality imaging capability of this new phantom with a thrombus visible in magnetic resonance (MR) angiography, CT angiography (CTA), digital subtraction angiography (DSA), and ultrasound, image acquisitions with all these modalities were performed by using standard clinical protocols. Potential use of this phantom for stent deployment was also tested. A rheometer allowed defining hyperelastic and viscoelastic properties of phantom materials. Results: MR imaging measurements of SNR and CNR values on T1 and T2-weighted sequences and MR angiography indicated reasonable agreement with published values of AAA thrombus and abdominal components in vivo. X-ray absorption also lay within normal ranges of AAA patients and was representative of findings observed on CTA, fluoroscopy, and DSA. Ultrasound propagation speeds for developed materials were also in

  9. The role of fenestration in promoting daylight performance. The mosques of Alexandria since the 19th century

    Directory of Open Access Journals (Sweden)

    Ingy I. El-Darwish

    2016-12-01

    Full Text Available Mosques have always been sacred places with distinctive sustainable environments. Fenestration in the prayers’ zone whether clerestories, screened windows, dome lighting and other light features have managed to produce significant spiritual human comfort areas. This paper focuses on fenestration of divine mosques and relates them to promoting daylight performance. The research process emphasizes the importance of daylight performance by promoting simulation tools on historical mosques of Alexandria since the 19th century that has witnessed change over time. The paper is a step toward sustainable lighting schemes in prayers’ zones that help to achieve human comfort as well as minimize use of energy. This study aimed at investigating the daylight performance by the use of climate based daylighting metrics which is “Daylight Autonomy” (DA. Daylight Autonomy is evaluated in the year round for the day lighted prayer periods to evaluate the behavior of fenestration of the different selected sample of mosques since the 19th century in Alexandria on a simulation tool in order to check whether it complies with the required illuminate and glare levels. The research findings are an attempt to lead to performative design guidelines introducing a contemporary interpretation for use in enhancing new designs of these holistic buildings.

  10. Fenestrated Transcatheter ASD Closure in Adults with Diastolic Dysfunction and/or Pulmonary Hypertension: Case Series and Review of the Literature.

    Science.gov (United States)

    Abdelkarim, Ayman; Levi, Daniel S; Tran, Bao; Ghobrial, Joanna; Aboulhosn, Jamil

    2016-12-01

    This study aims to evaluate the safety and efficacy of transcatheter fenestrated ASD closure and to summarize the literature regarding the published techniques and outcomes of transcatheter partial ASD closure. Patients with left ventricular diastolic dysfunction (LVDD) or right ventricular (RV) dysfunction and/or pulmonary hypertension (PHT) may suffer untoward consequences of complete closure of an ostium secundum atrial septal defect (ASD). Therefore, for patients that fall under these categories we suggest partial occlusion of the defect, which may be better tolerated than complete defect closure. After obtaining IRB approval, a search for patients that have undergone percutaneous ASD closure was performed in the Ahmanson/UCLA Adult Congenital Heart Disease Center database to identify which patients received a fenestrated ASD closure device. Eight consecutive patients ranging between 22 and 83 years of age (mean 48 years) with PHT and/or LVDD or RV dysfunction who underwent fenestrated transcatheter ASD closure at UCLA were identified. None of the subjects experienced complications related to the procedure. Postprocedure clinical evaluation showed improvement in symptoms and exercise capacity. Available follow-up transthoracic echocardiography data (mean 4 months, range 0-20 months) demonstrated patent fenestrations in four of eight patients. None of the patients had thromboembolic or infectious complications and there were no device migrations, erosions or embolizations. Partial ASD occlusion in patients with diastolic dysfunction or RV dysfunction and/or PHT is safe and may be better tolerated than complete ASD closure in selected patients. © 2016 Wiley Periodicals, Inc.

  11. Platelet-Rich Plasma Injection With Percutaneous Needling for Recalcitrant Lateral Epicondylitis: Comparison of Tenotomy and Fenestration Techniques

    Science.gov (United States)

    Gaspar, Michael P.; Motto, Michael A.; Lewis, Sarah; Jacoby, Sidney M.; Culp, Randall W.; Lee Osterman, A.; Kane, Patrick M.

    2017-01-01

    Background: Recalcitrant lateral epicondylitis (LE) is a common debilitating condition, with numerous treatment options of varying success. An injection of platelet-rich plasma (PRP) has been shown to improve LE, although it is unclear whether the method of needling used in conjunction with a PRP injection is of clinical importance. Purpose: To determine whether percutaneous needle tenotomy is superior to percutaneous needle fenestration when each is combined with a PRP injection for the treatment of recalcitrant LE. Study Design: Cohort study; Level of evidence, 3. Methods: A total of 93 patients with recalcitrant LE were treated with a PRP injection and percutaneous needle fenestration (n = 45) or percutaneous needle tenotomy (n = 48) over a 5-year study interval. Preoperative patient data, including visual analog scale for pain (VAS-P), Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH), and Patient-Rated Tennis Elbow Evaluation (PRTEE) scores and grip strength, were obtained from a chart review and compared with postoperative values obtained prospectively. Secondary outcomes included the incidence of complications, need for additional interventions, return to work, and patient satisfaction. Results: At a mean follow-up of 40 months, significant improvements in VAS-P (mean, –6.1; 95% CI, –6.8 to –5.5; P < .0001), QuickDASH (mean, –46; 95% CI, –52 to –40; P < .0001), and PRTEE (mean, –57; 95% CI, –64 to –50; P < .0001) scores and grip strength (mean, +6.1 kg; 95% CI, 4.9 to 7.3; P < .0001) were observed across the entire study cohort, with no significant differences noted between the fenestration and tenotomy groups. Nine of 45 patients (22%) underwent additional procedures to treat recurrent symptoms in the fenestration group compared with 5 of 48 patients (10%) in the tenotomy group (P = .05). No complications occurred in any patients, and no patients expressed dissatisfaction with their treatment course. Conclusion: A PRP injection

  12. Endovascular surgery in Marfan syndrome: CON.

    Science.gov (United States)

    Kouchoukos, Nicholas T

    2017-11-01

    The frequency of endovascular stent grafting procedures to treat various conditions of the thoracic aorta has increased dramatically over the past three decades. Stent grafting has been applied on a limited basis in patients with Marfan syndrome and other connective tissue disorders, despite recommendations from current guidelines and expert consensus statements against its use in this setting. A review of publications reporting outcomes after stent grafting of the descending thoracic aorta in Marfan patients with acute or chronic aortic dissection indicates that these procedures can be accomplished with rates of early mortality, stroke and spinal cord ischemic injury that are comparable to those observed in patients who do not have Marfan syndrome. However, the rates of primary treatment failure (principally endoleak), secondary treatment failure, need for open repair and late death among the Marfan patients are substantially higher than those observed in patients without this condition. In addition, the rates of retrograde aortic dissection and development of stent-graft induced new entry (SINE), are also greater among patients with Marfan syndrome. All of these findings argue strongly against the routine use of endovascular grafts in Marfan patients with type B or residual type A dissection. Few data are available to assess the role of endografting in Marfan patients with aneurysmal disease, but the progressive aortic dilatation noted in these patients argues strongly against its use in this setting as well. At present, the available data indicate that there is no justification for elective stent grafting in Marfan patients with aortic dissection or aneurysm. The only reasonable indications for primary aortic stent grafting are in the setting of acute aortic dissection or rupture, where the intervention is considered life-saving and rarely, considering the relatively young age of these patients, where the risk of open operation is considered to be prohibitive.

  13. Thoracoscopic pericardial fenestration for persistent pericardial effusion after radiotherapy for esophageal cancer. Report of a case

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Kazuhiro; Tsuchida, Kazuhito; Ariga, Takamitsu [Yokohama Rosai Hospital (Japan)

    2002-11-01

    We performed thoracoscopic pericardial fenestration for persistent pericardial effusion after radiotherapy for esophageal cancer. An 85-year-old man who had radiation therapy (70.2 Gy) for esophageal cancer was admitted for shortness of breath. Chest computed tomography showed a pericardial effusion. During the 6 months prior to this admission, the patient had undergone percutaneous pericardial drainage 3 times for cardiac tamponade. We performed thoracoscopic partial pericardiectomy with creation of a pleuropericardial window via one access port. Histopathologically, no malignant cells were found in either the resected pericardium or the pericardial effusion. Therefore, we believe the persistent pericardial effusion was secondary to radiotherapy. There was no recurrence of the pericardial effusion for 7 months postoperatively. In summary, thoracoscopic pericardial fenestration is useful in both the diagnosis and treatment of persistent pericardial effusion. (author)

  14. Endovascular Management of Infected Femoral Artery Pseudoaneurysms in High-Risk Patients: A Case Series

    Energy Technology Data Exchange (ETDEWEB)

    D’Oria, Mario, E-mail: mario.doria88@outlook.com; Sgorlon, Giada; Calvagna, Cristiano; Zamolo, Francesca; Chiarandini, Stefano; Adovasio, Roberto; Griselli, Filippo [University Hospital of Cattinara, Vascular and Endovascular Surgery Unit (Italy)

    2017-04-15

    We report our experience with the urgent treatment of two high-risk patients with infected femoral artery pseudoaneurysms (IFAPs) with the placement of a self-expandable covered stent (SECS). In both cases, there was no perioperative mortality and the aneurysm exclusion was successful without early or late stent thrombosis/stent fracture nor acute or chronic limb ischemia or limb loss. There was no recurrence of local or systemic infection during the follow-up period. Endovascular therapy represents a feasible treatment option for IFAPs in those patients for whom the risk of open surgical repair would be prohibitive, especially under urgent circumstances.

  15. Endovascular treatment of intracranial arteriovenous malformations

    International Nuclear Information System (INIS)

    Seruga, T.

    2002-01-01

    Background. The aim of the study was the introduction of endovascular interventional treatment of cerebral arteriovenous malformations (AVM) with superselective embolization with cyanoacrylic polymerisation agent. Case reports. Endovascular embolization was performed in five patients with cerebral AVMs. Three of these patients were presented with intracerebral haemathomas whereas in other two patients, cerebral AVM was an incidental finding. Superselective catheterisation of AVMs was performed and acrylic glue was selectively injected into the nidus. Conclusions. Control cerebral angiography after embolization of AVM showed different results. In one patient, AVM was totally occluded after three sessions and in second case AVM was occluded in a single session. The rate of occlusion in other two cases was estimated between 70% in 80%. Both of these two patients underwent surgery. One patient is still in the process of treatment. Endovascular treatment of cerebral AVMs with superselective embolization with liquid cyanoacrilyc adhesive agent is a safe and effective alternative treatment paths next to microsurgery. Endovascular treatment in combination with radiosurgery could become the method of choice in the therapy of cerebral AVMs in the future. (author)

  16. Endovascular treatment of spine and spinal cord lesions

    International Nuclear Information System (INIS)

    Berenstein, A.

    1992-01-01

    Completing this comprehensive series on endovascular interventional angiography, Volume 5 focuses on the vascular abnormalities of the spine and spinal cord. It is based on the detailed functional vascular anatomy described in Volume 3 and the principles and function of endovascular treatment described in Volumes 1-4. As in the companion volumes, the unique approach gives view of the disease itself, its anatomical features and its clinical presentation. The technical aspects of the interventional or endovascular neuroradiology are built upon the solid analysis of the disease and its angioarchitecture. The recent developments in endovascular procedures, such as aneurysm treatment, angioplasty, and vascular recanalizations, are reviewed. (orig.). 118 figs. in 442 separate illustrations

  17. Tratamento endovascular de lesões arteriais traumáticas Endovascular management of traumatic arterial injuries

    Directory of Open Access Journals (Sweden)

    Ruy Fernandes e Fernandes

    2011-03-01

    Full Text Available Introdução: As lesões arteriais traumáticas ocorrem em menos de 10% de politraumatizados e, nos países desenvolvidos, tem-se observado uma preponderância crescente de traumatismos vasculares iatrogénicos. Recentemente vários autores têm descrito a utilização de técnicas endovasculares com sucesso, pelo menor risco cirúrgico, em lesões de difícil acesso cujo tratamento convencional requer grande exposição cirúrgica, dificuldade técnica e mortalidade ou morbilidade apreciáveis. Os procedimentos endovasculares representam ainda uma alternativa terapêutica com menor mortalidade no tratamento de complicações crónicas de traumatismos vasculares, nomeadamente nos aneurismas pós-traumáticos do istmo aórtico (APTIA. Os autores apresentam uma série de doentes com lesões traumáticas arteriais diversas, em fase aguda ou crónica, tratados por via endovascular. Casos Clínicos: Sete doentes (21-77 anos, foram submetidos a tratamento endovascular de traumatismos vasculares na fase aguda ou crónica. Quatro doentes apresentavam lesões traumáticas agudas: 1 caso de rotura traumática do istmo aórtico (RTIA em politraumatismo por acidente de viação; 1 caso de rotura da artéria subclávia (RAS iatrogénica após tentativa de colocação de catéter de hemodiálise; 1 caso rotura de artéria renal (RAR durante angioplastia/stent por doença renovascular; 1 caso de fístula arterio-venosa (FAV da artéria renal intra-parenquimatosa iatrogénica após tumorectomia laparoscópica. Três doentes com complicações crónicas de traumatismos torácicos apresentavam falsos aneurismas do arco aórtico. Os doentes com roturas arteriais foram submetidos a exclusão endovascular com endoprótese e o doente com FAV renal foi submetido a embolização com coils. Os três doentes portadores de APTIA foram submetidos a: tratamento endovascular de aneurisma da aorta torácica (TEVAR-1; “debranching” com bypass carótido-subclávio e TEVAR-2

  18. Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?

    International Nuclear Information System (INIS)

    Baumueller, Stephan; Nguyen, Thi Dan Linh; Goetti, Robert Paul; Lachat, Mario; Seifert, Burkhardt; Pfammatter, Thomas; Frauenfelder, Thomas

    2011-01-01

    Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 ± 7.5 years, range 51–88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.

  19. Unusual rapid evolution of type B aortic dissection in a marfan patient following heart transplantation: successful endovascular treatment.

    Science.gov (United States)

    Botta, L; Russo, V; Grigioni, F; Arpesella, G; Rocchi, G; Di Bartolomeo, R; Fattori, R

    2006-10-01

    A patient with Marfan syndrome with previous Bentall operation for mitral and tricuspid valve repair, required orthotopic cardiac transplantation for end stage cardiomyopathy. Postoperatively he suffered type-B aortic dissection, despite normal aortic diameters. Following sudden increase of aortic diameters, two years later, he underwent successful stent graft implantation. In patients with Marfan syndrome, post transplantation morbidity is high, with a 40% incidence of thoracic aortic dissection. This case highlights the potential of endovascular approach for treating post-transplantation aortic dissection.

  20. Modified fenestration with restorative spinoplasty for lumbar spinal stenosis.

    Science.gov (United States)

    Matsudaira, Ko; Yamazaki, Takashi; Seichi, Atsushi; Hoshi, Kazuto; Hara, Nobuhiro; Ogiwara, Satoshi; Terayama, Sei; Chikuda, Hirotaka; Takeshita, Katsushi; Nakamura, Kozo

    2009-06-01

    The authors developed an original procedure, modified fenestration with restorative spinoplasty (MFRS) for the treatment of lumbar spinal stenosis. The first step is to cut the spinous process in an L-shape, which is caudally reflected. This procedure allows easy access to the spinal canal, including lateral recesses, and makes it easy to perform a trumpet-style decompression of the nerve roots without violating the facet joints. After the decompression of neural tissues, the spinous process is anatomically restored (spinoplasty). The clinical outcomes at 2 years were evaluated using the Japanese Orthopaedic Association (JOA) scale and patients' satisfaction. Radiological follow-up included radiographs and CT. Between January 2000 and December 2002, 109 patients with neurogenic intermittent claudication with or without mild spondylolisthesis underwent MFRS. Of these, 101 were followed up for at least 2 years (follow-up rate 93%). The average score on the self-administered JOA scale in 89 patients without comorbidity causing gait disturbance improved from 13.3 preoperatively to 22.9 at 2 years' follow-up. Neurogenic intermittent claudication disappeared in all cases. The patients' assessment of treatment satisfaction was "satisfied" in 74 cases, "slightly satisfied" in 12, "slightly dissatisfied" in 2, and "dissatisfied" in 1 case. In 16 cases (18%), a minimum progression of slippage occurred, but no symptomatic instability or recurrent stenosis was observed. Computed tomography showed that the lateral part of the facet joints was well preserved, and the mean residual ratio was 80%. The MFRS technique produces an adequate and safe decompression of the spinal canal, even in patients with narrow and steep facet joints in whom conventional fenestration is technically demanding.

  1. Construct canine intracranial aneurysm model by endovascular technique

    International Nuclear Information System (INIS)

    Liang Xiaodong; Liu Yizhi; Ni Caifang; Ding Yi

    2004-01-01

    Objective: To construct canine bifurcation aneurysms suitable for evaluating the exploration of endovascular devices for interventional therapy by endovascular technique. Methods: The right common carotid artery of six dogs was expanded with a pliable balloon by means of endovascular technique, then embolization with detached balloon was taken at their originations DAS examination were performed on 1, 2, 3 d after the procedurse. Results: 6 aneurysm models were created in six dogs successfully with the mean width and height of the aneurysms decreasing in 3 days. Conclusions: This canine aneurysm model presents the virtue in the size and shape of human cerebral bifurcation saccular aneurysms on DSA image, suitable for developing the exploration of endovascular devices for aneurismal therapy. The procedure is quick, reliable and reproducible. (authors)

  2. Endovascular Management of Acute Limb Ischemia.

    LENUS (Irish Health Repository)

    Hynes, Brian G

    2011-09-14

    Despite major advances in pharmacologic and endovascular therapies, acute limb ischemia (ALI) continues to result in significant morbidity and mortality. The incidence of ALI may be as high as 13-17 cases per 100,000 people per year, with mortality rates approaching 18% in some series. This review will address the contemporary endovascular management of ALI encompassing pharmacologic and percutaneous interventional treatment strategies.

  3. Endovascular Therapy of Ruptured Abdominal Aortic Aneurysm: Mid- and Long-Term Results

    International Nuclear Information System (INIS)

    Kubin, Klaus; Sodeck, Gottfried H.; Teufelsbauer, H.; Nowatschka, Bernd; Kretschmer, Georg; Lammer, Johannes; Schoder, Maria

    2008-01-01

    As an alternative to open aneurysm repair, emergency endovascular aortic repair (EVAR) has emerged as a promising technique for ruptured abdominal aortic aneurysm (rAAA) within the last decade. The aim of this retrospective study is to present early and late outcomes of patients treated with EVAR for rAAA. Twenty-two patients (5 women, 17 men; mean age, 74 years) underwent EVAR for rAAA between November 2000 and April 2006. Diagnostic multislice computed tomography angiography was performed prior to stent-graft repair to evaluate anatomical characteristics and for follow-up examinations. Periprocedural patient characteristics and technical settings were evaluated. Mortality rates, hospital stay, and early and late complications, within a mean follow-up time of 744 ± 480 days, were also assessed. Eight of 22 patients were hemodynamically unstable at admission. Stent-graft insertion was successful in all patients. The total early complication rate was 54%, resulting in a 30-day mortality rate of 23%. The median intensive care unit stay was 2 days (range, 2-48 days), and the median hospital stay was 16 days (range, 9-210 days). During the follow-up period, three patients suffered from stent-graft-related complications. The overall mortality rate in our study group was 36%. EVAR is an acceptable, minimally invasive treatment option in patients with acute rAAA, independent of the patient's general condition. Short- and long-term outcomes are definitely comparable to those with open surgical repair procedures

  4. [Value of fractional flow reserve measurement in endovascular therapy for patients with Stanford B type aortic dissection complicated with renal blood flow injury].

    Science.gov (United States)

    Guo, Xi; Li, Peng; Liu, Guangrui; Huang, Xiaoyong; Yong, Qiang; Wang, Guoqin; Huang, Lianjun

    2015-10-01

    To analyze the value of fractional flow reserve (FFR) measurement on endovascular therapy for patients with renal artery stenosis. Clinical data of 12 patients with Stanford B type aortic dissection complicated with renal blood flow injury in Anzhen hospital hospitalized from May 2013 to February 2014 were retrospectively analyzed. Renal artery angiography was performed and fractional flow reserve (FFR) was measured before Thoracic endovascular aortic repair. After operation, renal artery FFR was measured again, and renal artery stenting was performed in patients with FFR ≤ 0.90 or average pressure difference between proximal and distal of renal artery > 20 mmHg (1 mmHg = 0.133 kPa) and not applied for patients with FFR > 0.90.The patients were then subsequently followed up clinically. Kidney function were measured after 1 month, and contrast-enhanced ultrasonography data were obtained at 1 and 3 months later, respectively. The FFR of 1 patient was 0.90, while the FFR of other patients were less than 0.90 before thoracic endovascular aortic repair. After the procedure,the angiography showed that the blood flow of renal artery in 8 patients were fluency, and the FFR index was over 0.90. There were 4 patients with FFR less than 0.90. After renal artery stenting, the FFR of these 4 patients were all above 0.90. Compared with pre-procedure, blood urea nitrogen ((8.84 ± 3.99) mmol/L vs. (5.18 ± 1.69) mmol/L, P = 0.011) and uric acid ((359.3 ± 77.3) µmol/L vs. (276.9 ± 108.3) µmol/L, P = 0.008) decreased significantly after 1 month, and there was no significant difference in serum creatinine (P = 0.760). Contrast-enhanced ultrasonography results showed that blood flow of renal artery were fluency after 1 month and 3 months. In patients with aortic dissection complicating renal blood flow injury, the FFR measurement is meaningful in evaluating the blood flow status of target organs and guide the endovascular revascularization.

  5. Endovascular treatment of head and neck arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Dmytriw, A.A. [University Health Network, Joint Department of Medical Imaging, Toronto, Ontario (Canada); Ter Brugge, K.G.; Krings, T.; Agid, R. [Toronto Western Hospital, Division of Neuroradiology, Department of Medical Imaging, Toronto, Ontario (Canada)

    2014-03-15

    Head and neck arteriovenous malformations (H and N AVM) are associated with considerable clinical and psychosocial burden and present a significant treatment challenge. We evaluated the presentation, response to treatment, and outcome of patients with H and N AVMs treated by endovascular means at our institution. Patients with H and N AVMs treated by endovascular means from 1984 to 2012 were evaluated retrospectively. These included AVMs involving the scalp, orbit, maxillofacial, and upper neck localizations. Patient's clinical files, radiological images, catheter angiograms, and surgical reports were reviewed. Eighty-nine patients with H and N AVMs (46 females, 43 males; 48 small, 41 large) received endovascular therapy. The goals of treatment were curative (n = 30), palliative (n = 34), or presurgical (n = 25). The total number of endovascular treatment sessions was 244 (average of 1.5 per patient). The goal of treatment was met in 92.1 % of cases. Eventual cure was achieved in 42 patients accounting for 58.4 % (52/89) of all patients who underwent treatment for any goal. Twenty-eight of these patients were cured by embolization alone (28/89, 31.4 %) of which 18 were single-hole AVFs. Twenty-four were cured by planned surgical excision after presurgical embolization (24/89, 27 %). Seven patients (7/89, 7.2 %) suffered transient and two (2/89, 2.2 %) permanent endovascular treatment complications. Endovascular treatment is effective for H and N AVMs and relatively safe. It is particularly effective for symptom palliation and presurgical aid. Embolization is curative mostly in small lesions and single-hole fistulas. In patients with large non-curable H and N AVMs, endovascular therapy is often the only palliative option. (orig.)

  6. Endovascular repair of inadvertent arterial injury induced by central venous catheterization using a vascular closure device: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Hee; Jang, Woo Jin; Oh, Ju Heyon; Song, Yun Gyu [Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon (Korea, Republic of)

    2017-04-15

    Central venous catheterization can cause various complications. Inadvertent subclavian artery catheterization was performed during insertion of a central venous catheter in a 73-year-old man suffering from panperitonitis due to small-bowel perforation. Endovascular treatment was conducted to treat the injured subclavian artery with a FemoSeal vascular closure device.

  7. Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

    International Nuclear Information System (INIS)

    Saha, Prakash; Hughes, John; Patel, Ashish S.; Donati, Tommaso; Sallam, Morad; Patel, Sanjay D.; Bell, Rachel E.; Katsanos, Konstantinos; Modarai, Bijan; Zayed, Hany A.

    2015-01-01

    PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities

  8. Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Prakash, E-mail: prakash.2.saha@kcl.ac.uk; Hughes, John, E-mail: johnhughes387@rocketmail.com; Patel, Ashish S., E-mail: ashish.s.patel@kcl.ac.uk; Donati, Tommaso, E-mail: tommaso.donati@gstt.nhs.uk; Sallam, Morad, E-mail: morad.sallam@gstt.nhs.uk; Patel, Sanjay D., E-mail: sanjay.patel@gstt.nhs.uk; Bell, Rachel E. [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Modarai, Bijan, E-mail: bijan.modarai@kcl.ac.uk; Zayed, Hany A., E-mail: hany.zayed@gstt.nhs.uk [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2015-08-15

    PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities.

  9. Virtual reality simulation for the optimization of endovascular procedures: current perspectives

    Directory of Open Access Journals (Sweden)

    Rudarakanchana N

    2015-03-01

    Full Text Available Nung Rudarakanchana,1 Isabelle Van Herzeele,2 Liesbeth Desender,2 Nicholas JW Cheshire1 1Department of Surgery, Imperial College London, London, UK; 2Department of Thoracic and Vascular Surgery, Ghent University Hospital, Ghent, BelgiumOn behalf of EVEREST (European Virtual reality Endovascular RESearch TeamAbstract: Endovascular technologies are rapidly evolving, often requiring coordination and cooperation between clinicians and technicians from diverse specialties. These multidisciplinary interactions lead to challenges that are reflected in the high rate of errors occurring during endovascular procedures. Endovascular virtual reality (VR simulation has evolved from simple benchtop devices to full physic simulators with advanced haptics and dynamic imaging and physiological controls. The latest developments in this field include the use of fully immersive simulated hybrid angiosuites to train whole endovascular teams in crisis resource management and novel technologies that enable practitioners to build VR simulations based on patient-specific anatomy. As our understanding of the skills, both technical and nontechnical, required for optimal endovascular performance improves, the requisite tools for objective assessment of these skills are being developed and will further enable the use of VR simulation in the training and assessment of endovascular interventionalists and their entire teams. Simulation training that allows deliberate practice without danger to patients may be key to bridging the gap between new endovascular technology and improved patient outcomes.Keywords: virtual reality, simulation, endovascular, aneurysm

  10. Mid-term results of zone 0 thoracic endovascular aneurysm repair after ascending aorta wrapping and supra-aortic debranching in high-risk patients.

    Science.gov (United States)

    Pecoraro, Felice; Lachat, Mario; Hofmann, Michael; Cayne, Neal S; Chaykovska, Lyubov; Rancic, Zoran; Puippe, Gilbert; Pfammatter, Thomas; Mangialardi, Nicola; Veith, Frank J; Bettex, Dominique; Maisano, Francesco; Neff, Thomas A

    2017-06-01

    Surgical repair of aneurysmal disease involving the ascending aorta, aortic arch and eventually the descending aorta is generally associated with significant morbidity and mortality. A less invasive approach with the ascending wrapping technique (WT), supra-aortic vessel debranching (SADB) and thoracic endovascular aneurysm repair (TEVAR) in zone 0 was developed to reduce the associated risk in these patients. During a 10-year period, consecutive patients treated by the ascending WT, SADB and TEVAR in zone 0 were included. All patients were considered at high risk for conventional surgery. Measured outcomes included perioperative deaths and morbidity, maximal aortic transverse diameter (TD) and its postoperative evolution, endoleak, survival, freedom from cardiovascular reinterventions, SADB freedom from occlusion and aortic valve function during follow-up. Median follow-up was 37.4 [mean = 34; range, 0-65; standard deviation (SD) = 20] months. Twenty-six cases were included with a mean age of 71.88 ( r  = 56-87; SD = 8) years. A mean of 2.9 supra-aortic vessels (75) per patient was debranched from the ascending aorta. The mean time interval from WT/SADB and TEVAR was 29 ( r  = 0-204; SD = 48) days. TEVAR was associated with chimney and/or periscope grafts in 6 (23%) patients, and extra-anatomical supra-aortic bypasses were performed in 6 (23%) patients. Perioperative mortality was 7.7% (2/26). Neurological events were registered in 3 (11.5%) cases, and a reintervention was required in 3 (11.5%) cases. After the WT, the ascending diameter remained stable during the follow-up period in all cases. At mean follow-up, significant shrinkage of the arch/descending aorta diameter was observed. A type I/III endoleak occurred in 3 cases. At 5 years, the rates of survival, freedom from cardiovascular reinterventions and SADB freedom from occlusion were 71.7, 82.3 and 96%, respectively. The use of the ascending WT, SADB and TEVAR in selected patients

  11. Endovascular Intervention for Acute Ischemic Stroke in Light of Recent Trials

    Directory of Open Access Journals (Sweden)

    Kenan Alkhalili

    2014-01-01

    Full Text Available Three recently published trials, MR RESCUE, IMS III, and SYNTHESIS Expansion, evaluating the efficacy and safety of endovascular treatment of acute ischemic stroke have generated concerns about the future of endovascular approach. However, the tremendous evolution that imaging and endovascular treatment modalities have undergone over the past several years has raised doubts about the validity of these trials. In this paper, we review the role of endovascular treatment strategies in acute ischemic stroke and discuss the limitations and shortcomings that prevent generalization of the findings of recent trials. We also provide our experience in endovascular treatment of acute ischemic stroke.

  12. A look into the endovascular crystal ball

    DEFF Research Database (Denmark)

    Schroeder, Torben Veith

    2009-01-01

    This paper summarizes the highlights of the 15th International Workshop of Endovascular Surgery, held in Ajaccio in June 2008. This is an annual event that attracts leading endovascular therapists from both sides of the Atlantic Ocean as well as a contingency from down-under. The layout of this m...

  13. Perfect and least invasive sealing technique on the lesser curvature of the aortic arch: application of a novel stent graft to an aneurysm developing on a postoperative ductus arteriosus.

    Science.gov (United States)

    Soeda, Takeshi; Yokoi, Yoshihiko; Yuri, Koichi; Saito, Yuuhei; Setozaki, Shuji; Harada, Hisao

    2013-01-01

    A 78-year-old woman who underwent an operation for a patent ductus arteriosus (PDA) about thirty years ago developed an aneurysm on the aortic side of the remnant ductal tissue. To avoid risky, open surgery, we performed endovascular aortic therapy using a novel stent graft (SG), which was pre-curved, fenestrated and custom-made type. This graft was designed to configure to the patient's whole aortic arch anatomy, and was capable of accurately adjusting its fenestrations to the arch branch orifices during the procedure. The operation was successful, and the patient was discharged uneventfully on 16th postoperative day. The advantage of this fenestrated SG is close sealing, especially over the lesser curvature of the arch. This device could be a simple and effective option to deal with an otherwise normal aortic arch with such a ductus-related localized lesion.

  14. Endovascular Treatment of Descending Thoracic Aortic Aneurysms with the EndoFit Stent-Graft

    International Nuclear Information System (INIS)

    Saratzis, N.; Saratzis, Athanasios; Melas, N.; Ginis, G.; Lioupis, A.; Lykopoulos, D.; Lazaridis, J.; Kiskinis, Dimitrios

    2007-01-01

    Objective. To evaluate the mid-term feasibility, efficacy, and durability of descending thoracic aortic aneurysm (DTAA) exclusion using the EndoFit device (LeMaitre Vascular). Methods. Twenty-three (23) men (mean age 66 years) with a DTAA were admitted to our department for endovascular repair (21 were ASA III+ and 2 refused open repair) from January 2003 to July 2005. Results. Complete aneurysm exclusion was feasible in all subjects (100% technical success). The median follow-up was 18 months (range 8-40 months). A single stent-graft was used in 6 cases. The deployment of a second stent-graft was required in the remaining 17 patients. All endografts were attached proximally, beyond the left subclavian artery, leaving the aortic arch branches intact. No procedure-related deaths have occurred. A distal type I endoleak was detected in 2 cases on the 1 month follow-up CT scan, and was repaired with reintervention and deployment of an extension graft. A nonfatal acute myocardial infarction occurred in 1 patient in the sixth postoperative month. Graft migration, graft infection, paraplegia, cerebral or distal embolization, renal impairment or any other major complications were not observed. Conclusion. The treatment of DTAAs using the EndoFit stent-graft is technically feasible. Mid-term results in this series are promising

  15. Retrograde type A dissection: a serious complication due to thoracic aortic endovascular stent-graft repair for Stanford type B aortic dissection

    International Nuclear Information System (INIS)

    Wang Guoquan; Zhai Shuiting; Li Tianxiao; Shi Shuaitao; Zhang Kewei; Li Kun

    2011-01-01

    Objective: to discuss the possible causes and prevention of retrograde type A dissection occurred after thoracic aortic endovascular stent-graft repair (TEVAR) for symptomatic type B dissection. Methods: During the period from January 2005 to January 2011, TEVAR was carried out in 189 patients (157 males and 32 females) with symptomatic type B dissection. The average age of the patients was (51.2±13.5) years, ranged from 26 to 78 years. A follow-up lasting for 3-63 months (mean 32 months) was conducted in 135 patients (71.43%). Fifty-four patients lost in touch with the authors (28.57%). The occurrence of retrograde type A dissection after TEVAR was calculated and the possible causes were analyzed. Results: After TEVAR retrograde type A dissection occurred in two patients (1.48%), and both were males. One patient developed retrograde type A dissection in perioperative period, and the patient refused to have surgery. Conservative treatment was employed for over three years and be was still alive so far. The other patient developed retrograde type A dissection one month after TEVAR, and emergency surgery was performed. The patient was followed up for three months and he was still alive. Conclusion: The retrograde type A dissection occurred after TEVAR may be closely related to the stent-graft device, to the interventional manipulations and to the vascular disorders. Close attention should be paid to the direct damage produced by the stent-graft device to the vascular wall. (authors)

  16. Systematic review of recent evidence for the safety and efficacy of elective endovascular repair in the management of infrarenal abdominal aortic aneurysm.

    Science.gov (United States)

    Drury, D; Michaels, J A; Jones, L; Ayiku, L

    2005-08-01

    Conventional management of abdominal aortic aneurysm (AAA) is by open repair and is associated with a mortality rate of 2-6 per cent. Endovascular aneurysm repair (EVAR) is an alternative technique first introduced in 1991. A systematic review was undertaken of the evidence for the safety and efficacy of elective EVAR in the management of asymptomatic infrarenal AAA. Thirteen electronic bibliographical databases were searched, covering biomedical, health-related, science and social science literature. Outcomes were assessed with respect to efficacy (successful deployment, technical success, conversion rates and secondary intervention rates) and safety (30-day mortality rate, procedure morbidity rates and technical issues-endoleaks, graft thrombosis, stenosis and migration). Of 606 reports identified, 61 met the inclusion criteria (three randomized and 15 non-randomized controlled trials, and 43 uncontrolled studies). There were 29 059 participants in total; 19,804 underwent EVAR. Deployment was successful in 97.6 per cent of cases. Technical success (complete aneurysm exclusion) was 81.9 per cent at discharge and 88.8 per cent at 30 days. Secondary intervention to treat endoleak or maintain graft patency was required in 16.2 per cent of patients. Mean stay in the intensive care unit and mean hospital stay were significantly shorter following EVAR. The 30-day mortality rate for EVAR was 1.6 per cent (randomized controlled trials) and 2.0 per cent in nonrandomized trials and case series. Technical complications comprised stent migration (4.0 per cent), graft limb thrombosis (3.9 per cent), endoleak (type I, 6.8 per cent; type II, 10.3 per cent; type III, 4.2 per cent) and access artery injury (4.8 per cent). EVAR is technically effective and safe, with lower short-term morbidity and mortality rates than open surgery. However, there is a need for extended follow-up as the long-term success of EVAR in preventing aneurysm-related deaths is not yet known.

  17. Virtual reality simulation for the optimization of endovascular procedures: current perspectives.

    Science.gov (United States)

    Rudarakanchana, Nung; Van Herzeele, Isabelle; Desender, Liesbeth; Cheshire, Nicholas J W

    2015-01-01

    Endovascular technologies are rapidly evolving, often requiring coordination and cooperation between clinicians and technicians from diverse specialties. These multidisciplinary interactions lead to challenges that are reflected in the high rate of errors occurring during endovascular procedures. Endovascular virtual reality (VR) simulation has evolved from simple benchtop devices to full physic simulators with advanced haptics and dynamic imaging and physiological controls. The latest developments in this field include the use of fully immersive simulated hybrid angiosuites to train whole endovascular teams in crisis resource management and novel technologies that enable practitioners to build VR simulations based on patient-specific anatomy. As our understanding of the skills, both technical and nontechnical, required for optimal endovascular performance improves, the requisite tools for objective assessment of these skills are being developed and will further enable the use of VR simulation in the training and assessment of endovascular interventionalists and their entire teams. Simulation training that allows deliberate practice without danger to patients may be key to bridging the gap between new endovascular technology and improved patient outcomes.

  18. Endovascular treatment of carotid-cavernous vascular lesions

    Directory of Open Access Journals (Sweden)

    GUILHERME BRASILEIRO DE AGUIAR

    Full Text Available ABSTRACT Objective: to evaluate the endovascular treatment of vascular lesions of the cavernous segment of the internal carotidartery (ICA performed at our institution. Methods: we conducted a descriptive, retrospective and prospective study of patients with aneurysms of the cavernous portion of the ICA or with direct carotid-cavernous fistulas (dCCF undergoing endovascular treatment. Results: we included 26 patients with intracavernous aneurysms and ten with dCCF. All aneurysms were treated with ICA occlusion. Those with dCCF were treated with occlusion in seven cases and with selective fistula occlusion in the remaining three. There was improvement of pain and ocular proptosis in all patients with dCCF. In patients with intracavernous aneurysms, the incidence of retro-orbital pain fell from 84.6% to 30.8% after treatment. The endovascular treatment decreased the dysfunction of affected cranial nerves in both groups, especially the oculomotor one. Conclusion: the endovascular treatment significantly improved the symptoms in the patients studied, especially those related to pain and oculomotor nerve dysfunction.

  19. Intentional left subclavian artery coverage during thoracic endovascular aortic repair for traumatic aortic injury.

    Science.gov (United States)

    McBride, Cameron L; Dubose, Joseph J; Miller, Charles C; Perlick, Alexa P; Charlton-Ouw, Kristofer M; Estrera, Anthony L; Safi, Hazim J; Azizzadeh, Ali

    2015-01-01

    Thoracic endovascular aortic repair (TEVAR) is widely used for treatment of traumatic aortic injury (TAI). Stent graft coverage of the left subclavian artery (LSA) may be required in up to 40% of patients. We evaluated the long-term effects of intentional LSA coverage (LSAC) on symptoms and return to normal activity in TAI patients compared with a similarly treated group whose LSA was uncovered (LSAU). Patients were identified from a prospective institutional trauma registry between September 2005 and July 2012. TAI was confirmed using computed tomography angiography. The electronic medical records, angiograms, and computed tomography angiograms were reviewed in a retrospective fashion. In-person or telephone interviews were conducted using the SF-12v2 (Quality Metrics, Lincoln, RI) to assess quality of life. An additional questionnaire was used to assess specific LSA symptoms and the ability to return to normal activities. Data were analyzed by Spearman rank correlation and multiple linear and logistic regression analysis with appropriate transformations using SAS software (SAS Institute, Cary, NC). During the study period, 82 patients (57 men; mean age 40.5 ± 20 years, mean Injury Severity Score, 34 ± 10.0) underwent TEVAR for treatment of TAI. Among them, LSAC was used in 32 (39.5%) and LSAU in 50. A group of the LSAU patients (n = 22) served as matched controls in the analysis. We found no statistically significant difference in SF-12v2 physical health scores (ρ = -0.08; P = .62) between LSAC and LSAU patients. LSAC patients had slightly better mental health scores (ρ = 0.62; P = .037) than LSAU patients. LSAC patients did not have an increased likelihood of experiencing pain (ρ = -0.0056; P = .97), numbness (ρ = -0.12; P = .45), paresthesia (ρ = -0.11; P = .48), fatigue (ρ = -0.066; P = .69), or cramping (ρ = -0.12; P = .45). We found no difference between groups in the ability to return to activities. The mean follow-up time was 3.35 years. Six LSAC

  20. Endovascular Exclusion of an Abdominal Aortic Aneurysm in Patients with Concomitant Abdominal Malignancy: Early Experience

    Energy Technology Data Exchange (ETDEWEB)

    Choi, You Ri; Chang, Nam Kyu [Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of); Shin, Hyo Hyun; Oh, Hyun Jun; Kim, Jae Kyu; Choi, Soo Jin Na; Chung, Sang Young [Chonnam National University Hospital, Gwangju (Korea, Republic of); Yim, Nam Yeol [Armed Forces Yangju Hospital, Yangju (Korea, Republic of)

    2010-08-15

    To assess the outcomes of endovascular aortic aneurysm repair (EVAR) for the treatment of an abdominal aortic aneurysm in patients undergoing curative surgical treatment for concomitant abdominal malignancy. The study included 12 patients with abdominal neoplasia and an abdominal aortic aneurysm (AAA), which was treated by surgery and stent EVAR. The neoplasm consisted of the gastric, colorectal, pancreas, prostate, and gall bladder. The follow up period was 3-21 months (mean 11.8 months). All medical records and imaging analyses were reviewed by CTA and/or color Doppler US, retrospectively. Successful endoluminal repair was accomplished in all twelve patients. The mean interval time between EVAR and surgery was 58.6 days. Small amounts of type 2 endoleaks were detected in two patients (17%). One patient developed adult respiratory distress syndrome after Whipple's operation 20 days after surgery, which led to hopeless discharge. No procedure-related mortality, morbidity, or graft-related infection was noted. Exclusion of AAA in patients with accompanying malignancy show with a relatively low procedure morbidity and mortality. Hence, endoluminal AAA repair in patients with synchronous neoplasia may allow greater flexibility in the management of an offending malignancy

  1. Endovascular Exclusion of an Abdominal Aortic Aneurysm in Patients with Concomitant Abdominal Malignancy: Early Experience

    International Nuclear Information System (INIS)

    Choi, You Ri; Chang, Nam Kyu; Shin, Hyo Hyun; Oh, Hyun Jun; Kim, Jae Kyu; Choi, Soo Jin Na; Chung, Sang Young; Yim, Nam Yeol

    2010-01-01

    To assess the outcomes of endovascular aortic aneurysm repair (EVAR) for the treatment of an abdominal aortic aneurysm in patients undergoing curative surgical treatment for concomitant abdominal malignancy. The study included 12 patients with abdominal neoplasia and an abdominal aortic aneurysm (AAA), which was treated by surgery and stent EVAR. The neoplasm consisted of the gastric, colorectal, pancreas, prostate, and gall bladder. The follow up period was 3-21 months (mean 11.8 months). All medical records and imaging analyses were reviewed by CTA and/or color Doppler US, retrospectively. Successful endoluminal repair was accomplished in all twelve patients. The mean interval time between EVAR and surgery was 58.6 days. Small amounts of type 2 endoleaks were detected in two patients (17%). One patient developed adult respiratory distress syndrome after Whipple's operation 20 days after surgery, which led to hopeless discharge. No procedure-related mortality, morbidity, or graft-related infection was noted. Exclusion of AAA in patients with accompanying malignancy show with a relatively low procedure morbidity and mortality. Hence, endoluminal AAA repair in patients with synchronous neoplasia may allow greater flexibility in the management of an offending malignancy

  2. Investigation of reference levels and radiation dose associated with abdominal EVAR (endovascular aneurysm repair) procedures across several European Centres

    Energy Technology Data Exchange (ETDEWEB)

    Tuthill, E.; Rainford, L. [University College Dublin, Diagnostic Imaging, School of Medicine, Dublin (Ireland); O' Hora, L.; O' Donohoe, M. [Mater Misericordiae University Hospital, Dublin (Ireland); Panci, S. [San Giovanni di Dio Hospital, Florence (Italy); Gilligan, P.; Fox, E. [Mater Private Hospital, Dublin (Ireland); Campion, D. [Mauriziano-Umberto Hospital, Turin (Italy); Trenti, R. [Policlinico S. Orsola-Malpighi, Bologna (Italy); Catania, D. [AITRI, Association of Italian Interventional Radiographers, Milan (Italy)

    2017-11-15

    Endovascular aneurysm repair (EVAR) is considered the treatment of choice for abdominal aortic aneurysms with suitable anatomy. In order to improve radiation safety, European Directive (2013/59) requires member states to implement diagnostic reference levels (DRLs) in radio-diagnostic and interventional procedures. This study aimed to determine local DRLs for EVAR across five European centres and identify an interim European DRL, which currently remains unestablished. Retrospective data was collected for 180 standard EVARs performed between January 2014 and July 2015 from five specialist centres in Ireland (n=2) and Italy (n=3). Data capture included: air kerma-area product (P{sub KA}), total air kerma at the reference point (K{sub a,r}), fluoroscopic time (FT), number of acquisitions, frame rate of acquisition, type of acquisition, patient height, weight, and gender. The mean values for each site A, B, C, D, and E were: P{sub KA}s of 4343 ± 994 μGym{sup 2}, 18,200 ± 2141 μGym{sup 2}, 11,423 ± 1390 μGym{sup 2}, 7796 ± 704 μGym{sup 2}, 31,897 ± 5798 μGym{sup 2}; FTs of 816 ± 92 s, 950 ± 150 s, 708 ± 70 s, 972 ± 61 s, 827 ± 118 s; and number of acquisitions of 6.72 ± 0.56, 10.38 ± 1.54, 4.74 ± 0.19, 5.64 ± 0.36, 7.28 ± 0.65, respectively. The overall pooled 75th percentile P{sub KA} was 15,849 μGym{sup 2}. Local reference levels were identified. The pooled data has been used to establish an interim European DRL for EVAR procedures. (orig.)

  3. Mortality within the endovascular treatment in Stanford type B aortic dissections Mortalidade no tratamento endovascular nas dissecções aórticas tipo B

    Directory of Open Access Journals (Sweden)

    Alexandre Fioranelli

    2011-06-01

    Full Text Available BACKGROUND: Endovascular stent-graft repair of aortic dissections is a relatively new procedure, and although apparently less invasive, the efficacy and safety of this technique have not been fully established. OBJECTIVE: To evaluate mortality in patients with complicated Stanford type B aortic dissections submitted to endovascular treatment. METHODS: Clinical, anatomical, imaging and autopsy data of 23 patients with complicated type B aortic dissections were reviewed from November 2004 to October 2007. The main indications for transluminal thoracic stent-grafting included: persistent pain in spite of medical therapy, signs of distal limb ischemia, signs of aortic rupture, progression of aneurismal dilation of the descending aorta during follow-up (defined as a diameter > 50 mm and the diameter of descending thoracic aorta of 40mm or larger at the onset of aortic dissection. Data were analyzed statistically; all p-values were two-tailed and differences INTRODUÇÃO: O tratamento endovascular na dissecção de aorta é um procedimento relativamente novo e, embora aparentemente menos invasivo, a eficácia e a segurança dessa técnica não estão totalmente estabelecidas. OBJETIVO: Avaliar a mortalidade e complicações nos pacientes submetidos a tratamento endovascular na dissecção de aorta tipo B de Stanford. MÉTODOS: Foram revisados, a partir de novembro de 2004 a outubro de 2007, em estudo clínico, anatômico, de imagens e dados da autopsia de 23 pacientes com dissecção aórtica tipo B. As principais indicações para o procedimento foram: dor persistente apesar da terapia médica, sinais de isquemia distal do membro, sinais de ruptura da aorta, progressão da dilatação do aneurisma da aorta descendente, durante o seguimento (definida como um diâmetro > 5 cm e descendente da aorta torácica de 40 mm ou mais de diâmetro no início da dissecção aórtica. Os dados foram analisados estatisticamente considerados erro alfa de 5%. As vari

  4. Reduction in incidence of lymphocele following extraperitoneal radical prostatectomy and pelvic lymph node dissection by bilateral peritoneal fenestration.

    Science.gov (United States)

    Stolzenburg, Jens-Uwe; Wasserscheid, Johanna; Rabenalt, Robert; Do, Minh; Schwalenberg, Thilo; McNeill, Alan; Constantinides, Costantinos; Kallidonis, Panagiotis; Ganzer, Roman; Liatsikos, Evangelos

    2008-12-01

    In our series of 1,900 endoscopic extraperitoneal radical prostatectomies (EERPE) the incidence of symptomatic lymphocele following simultaneous pelvic lymph node dissection (PLND) is between 3 and 14% depending on the extent of lymph node dissection. We report the impact of bilateral peritoneal fenestration after completion of extraperitoneal prostatectomy and PLND on the incidence of lymphocele, postoperative pain and complications. A total of 100 consecutive patients undergoing EERPE and extended PLND were allocated into two groups. In Group A (n = 50) a 4-6 cm incision was performed bilaterally over the external iliac vessels down to the obturator fossa after completion of the main procedure. In Group B (n = 50) no peritoneal incisions were made. The postoperative assessment protocol included a visual analogue pain scale administered three times daily for 6 days, analgesia requirement, and ultrasound examination on 4th and 8th days, and 3 months postoperatively. CRP and leucocyte counts were measured on 1st and 2nd postoperative days. Complications were recorded according to our standard protocol using the Clavien classification. Three patients (6%) in Group A were found to have lymphoceles, none of which were symptomatic. Significantly more patients in Group B developed a lymphocele, (n = 16, 32%, P < 0.001) of which a significant number were symptomatic (n = 7, 14%, P < 0.001) and required laparoscopic fenestration. No significant difference was observed between the pain score in either group. Mean pain scores were 3.4 versus 3.8 at 6 h, and 0.8 versus 1.1 at 6 days, respectively. No difference in analgesia requirement, serum inflammatory markers and return to normal bowel activity was observed between the groups. This study demonstrates that peritoneal fenestration significantly reduces the incidence of both symptomatic and asymptomatic lymphocele, without an increase in postoperative morbidity. As symptomatic lymphocele is one of the most common

  5. Retrograde Embolization of the Left Vertebral Artery in a Type II Endoleak After Endovascular Treatment of Aortic Thoracic Rupture: Technical Note

    International Nuclear Information System (INIS)

    Rabellino, Martin; Garcia Nielsen, L.; Baldi, S.; Zander, T.; Arnaiz, L.; Llorens, R.; Zerolo, I.; Maynar, M.

    2009-01-01

    Endoleak is a frequent complication after endovascular repair of aortic rupture. We describe the case of a female patient with traumatic aortic injury, treated with endograft, who developed a type II endoleak through the left subclavian and vertebral arteries. Both arteries originated independently from the aortic arch, and were managed with coil embolization of each vessel. We also report our experience with treating the left vertebral artery by placing a microcatheter through the right vertebral one.

  6. Endovascular interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bartels, L W; Bakker, C J G

    2003-01-01

    Minimally invasive interventional radiological procedures, such as balloon angioplasty, stent placement or coiling of aneurysms, play an increasingly important role in the treatment of patients suffering from vascular disease. The non-destructive nature of magnetic resonance imaging (MRI), its ability to combine the acquisition of high quality anatomical images and functional information, such as blood flow velocities, perfusion and diffusion, together with its inherent three dimensionality and tomographic imaging capacities, have been advocated as advantages of using the MRI technique for guidance of endovascular radiological interventions. Within this light, endovascular interventional MRI has emerged as an interesting and promising new branch of interventional radiology. In this review article, the authors will give an overview of the most important issues related to this field. In this context, we will focus on the prerequisites for endovascular interventional MRI to come to maturity. In particular, the various approaches for device tracking that were proposed will be discussed and categorized. Furthermore, dedicated MRI systems, safety and compatibility issues and promising applications that could become clinical practice in the future will be discussed. (topical review)

  7. Tratamento endovascular de ruptura traumática da aorta torácica descendente Endovascular treatment of traumatic descending thoracic aortic rupture

    Directory of Open Access Journals (Sweden)

    João Roberto Breda

    2007-06-01

    Full Text Available Paciente do sexo feminino, 55 anos de idade, vítima de atropelamento, foi admitida em unidade de emergência, onde se realizou o diagnóstico clínico, radiológico e tomográfico de ruptura traumática da aorta torácica descendente. Diante do achado, a paciente foi encaminhada para tratamento endovascular com colocação de endoprótese auto-expansível (stent pela artéria femoral. O tratamento obteve sucesso, evidenciado pela exclusão da lesão localizada previamente no istmo aórtico. O tratamento endovascular tem sido indicado nas afecções de aorta torácica descendente com bons resultados iniciais. Na ruptura traumática de aorta, a terapêutica endovascular representa uma alternativa aceitável, especialmente devido aos riscos do tratamento operatório convencional.A 55-year-old, female patient who was run over by a motor vehicle was admitted at an emergency room. Clinical, radiological and tomographic diagnosis of traumatic descending aortic thoracic rupture was performed. The patient was referred for endovascular treatment with placement of a self-expandable stent through the femoral artery. Treatment was successful, with exclusion of the lesion previously located in the aortic isthmus. Endovascular treatment has been indicated in the treatment of descending thoracic aortic diseases, with good initial results. In case of traumatic aortic rupture, endovascular treatment is a feasible alternative, especially due to risks offered by the conventional surgical treatment.

  8. Simulation and augmented reality in endovascular neurosurgery: lessons from aviation.

    Science.gov (United States)

    Mitha, Alim P; Almekhlafi, Mohammed A; Janjua, Major Jameel J; Albuquerque, Felipe C; McDougall, Cameron G

    2013-01-01

    Endovascular neurosurgery is a discipline strongly dependent on imaging. Therefore, technology that improves how much useful information we can garner from a single image has the potential to dramatically assist decision making during endovascular procedures. Furthermore, education in an image-enhanced environment, especially with the incorporation of simulation, can improve the safety of the procedures and give interventionalists and trainees the opportunity to study or perform simulated procedures before the intervention, much like what is practiced in the field of aviation. Here, we examine the use of simulators in the training of fighter pilots and discuss how similar benefits can compensate for current deficiencies in endovascular training. We describe the types of simulation used for endovascular procedures, including virtual reality, and discuss the relevant data on its utility in training. Finally, the benefit of augmented reality during endovascular procedures is discussed, along with future computerized image enhancement techniques.

  9. Editor's Choice - Prolonged ICU Length of Stay after AAA Repair: Analysis of Time Trends and Long-term Outcome.

    Science.gov (United States)

    Gavali, H; Mani, K; Tegler, G; Kawati, R; Covaciu, L; Wanhainen, A

    2017-08-01

    The aim of the study was to investigate the frequency and outcome of prolonged intensive care unit (ICU) length of stay (LOS) after abdominal aortic aneurysm (AAA) repair in the endovascular era. All patients operated on for AAA between 1999 and 2013 at Uppsala University hospital were identified. Data were retrieved from the Swedish Vascular registry, the Swedish Intensive Care registry, the National Population registry, and case records. Prolonged ICU LOS was defined as ≥ 48 h during the primary hospital stay. Patients surviving ≥ 48 h after AAA surgery were included in the analysis. A total of 725 patients were identified, of whom 707 (97.5%) survived ≥ 48 h; 563 (79.6%) underwent intact AAA repair and 144 (20.4%) ruptured AAA repair. A total of 548 patients (77.5%) required AAA repairs in 1999 to 7.3% in 2013 (p < .001) whereas the use of endovascular aortic repair (EVAR) increased from 6.9% in 1999 to 78.0% in 2013 (p < .001). The 30 day survival rate was 98.2% for those with < 48 h ICU stay versus 93.0% for 2-6 days versus 81.8% for ≥ 7 days (p < .001); the corresponding 90 day survival was 97.1% versus 86.1% versus 63.6% (p < .001) respectively. For patients surviving 90 days after repair, there was no difference in long-term survival between the groups. During the period of progressively increasing use of EVAR, a simultaneous significant reduction in frequency of prolonged ICU LOS occurred. Although prolonged ICU LOS was associated with a high short-term mortality, long-term outcome among those surviving the initial 90 days was less affected. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Fenestrated atrial septal defect percutaneously occluded by a single device: procedural and financial considerations.

    Science.gov (United States)

    Tal, Roie; Dahud, Qarawani; Lorber, Avraham

    2013-06-01

    A 45-year-old patient presented with a cerebrovascular attack and was subsequently found to have a multi-fenestrated atrial septal defect. Various therapeutic options for percutaneous transcatheter closure with their respective benefits and flaws are discussed, as well as procedural and financial considerations. The decision making process leading to a successful result using a single occlusive device is presented, alongside a review of the literature.

  11. Treatment of a Common Iliac Aneurysm by Endovascular Exclusion Using the Amplatzer Vascular Plug and Femorofemoral Crossover Graft

    International Nuclear Information System (INIS)

    Coupe, Nicholas J.; Ling, Lynn; Cowling, Mark G.; Asquith, John R.; Hopkinson, Gregory B.

    2009-01-01

    We report our initial experience using the Amplatzer Vascular Plug II (AVP2) in the treatment of a left common iliac aneurysm. Following investigation by computerized tomographic angiography and catheter angiography, a 79-year-old man was found to have a markedly tortuous iliac system, with a left common iliac artery aneurysm that measured 48 mm in maximal diameter. Due to the patient's age and comorbidities the surgical opinion was that conventional open repair was not suitable. However, due to the tortuous nature of the aneurysm and iliac vessels, standard endovascular repair, using either a bifurcated or an aorto-uni-iliac stent graft, was also not possible. A combined approach was used by embolizing the ipsilateral internal iliac artery using coils and excluding the aneurysm using two AVP2 occlusion devices, followed by femorofemoral crossover grafting. Total aneurysm occlusion was achieved using this method and this allowed the patient to have a much less invasive surgical procedure than with conventional open repair of common iliac aneurysms, thus avoiding potential comorbidity and mortality.

  12. Endovascular strategy for the elective treatment of concomitant aortoiliac aneurysm and symptomatic large bowel diverticular disease.

    Science.gov (United States)

    Illuminati, Giulio; Ricco, Jean-Baptiste; Schneider, Fabrice; Caliò, Francesco G; Ceccanei, Gianluca; Pacilè, Maria A; Pizzardi, Giulia; Palumbo, Piergaspare; Vietri, Francesco

    2014-07-01

    The purpose of this study was to evaluate the strategy for treatment of patients presenting with asymptomatic diverticular disease of the large bowel associated with an asymptomatic aortoiliac aneurysmal (AAA) disease. Sixty-nine patients were included in this retrospective study. The patients were divided into 5 groups according to the type and sequence of the surgical treatment: 32 patients (47%) underwent colectomy followed by a staged open AAA repair (group A); 10 patients (14%) were treated with open AAA repair followed by a staged colectomy (group B); 13 patients (18%) received endovascular aneurysm repair (EVAR) followed by a staged bowel resection (group C); 8 patients (12%) had a bowel resection followed by staged EVAR (group D); and 6 patients (9%) underwent simultaneous open AAA repair and bowel resection (group E). Primary end points were mortality and complications after any of the procedures. Secondary end point was the time interval between the staged procedures. The cumulative death rate for delayed treatment of AAA was 6.5% and 0% for delayed treatment of diverticular disease [P=0.22]. The mean time interval between the staged procedures was 11 days for EVAR/colon resection (group C and group D) and 73 days for open AAA repair/colon resection (group A and group B; P<0.01). EVAR allows a significant reduction in the time required between AAA repair and colon resection, but no definite rule can be established regarding the sequence of staged procedures. Combined procedures should be reserved for selected cases. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. The management of unimplantable stent during endovascular procedure:report of three cases

    International Nuclear Information System (INIS)

    Xiong Jiang; Wang Lijun; Guo Wei; Liu Xiaoping; Yin Tai; Jia Xin; Ma Xiaohui; Liu Meng; Zhang Hongpeng; Zhang Minhong

    2010-01-01

    Objective: To summarize the experience of dealing with the difficulty of the stent implantation encountered in the endovascular procedure. Methods: The causes of unimplantable stent encountered in the endovascular procedure included the delivery system entraping due to the stenosis and shrinking of peripheral self-expandable stent, the balloon expandable stent implantation and retrievement failure due to the rupture-balloon or stent edge opening, and the delivery system entraping due to aortic stent graft for aorta kinking. The balloon dilation for the stenosis and shrinking stent, the large caliber introducer sheath for removal of the rupture-balloon and edge opening, the expandable stent and balloon-assisted delivery system retrieve were used to solve the above three dilemma of unimplantable stent occurred in the endovascular procedure. Results: These three dilemma of stent unimplantable problem in the endovascular therapy were solved by endovascular method while little additional incision injury was added to the patients. Conclusion: For solving stent unimplantable problem the endovascular technique is the method of first choice, nevertherless, it is very important for the operator to be highly skilled in manipulating endovascular procedure. (authors)

  14. Endovascular treatment in pregnancy

    International Nuclear Information System (INIS)

    Ishii, Akira; Miyamoto, Susumu

    2013-01-01

    There is an increased risk of stroke during pregnancy and the puerperium. Decisions should be made immediately upon transfer to each institution, particularly with respect to when and how to treat the patient. This review highlights the feasibility of endovascular treatment in pregnancy. Most of the pharmaceutical agents and therapeutic devices used in clinical practice can be utilized in pregnant patients. Comprehensive information on the benefits and risks of treatment should be explained to the patient and her family, with particular attention to the safety of the mother and fetus. Radiation exposure to the fetus is also a concern; the hazard can be minimized with optimal protection. Several studies have demonstrated that conventional procedures do not cause serious radiation exposure exceeding the threshold of safety to the fetus. Endovascular therapy can be safely performed for the treatment of acute stroke as in non-pregnant patients with adequate attention to pharmaceutical agents and shielding from radiation. In contrast to therapy for acute stroke, preventive endovascular treatment for asymptomatic lesions remains controversial. Several conditions, such as cerebral aneurysms and arteriovenous malformations, are known to bleed more frequently in pregnancy, but whether the benefits of preventive treatment outweigh the associated risks is unknown. The decision for preventive treatment should be carefully made on a case-by-case basis after extensive discussion with the patient. (author)

  15. Ten-Year Follow-Up of Endovascular Aneurysm Treatment with Talent Stent-Grafts

    International Nuclear Information System (INIS)

    Pitton, Michael B.; Scheschkowski, Tobias; Ring, Markus; Herber, Sascha; Oberholzer, Katja; Leicher-Dueber, Annegret; Neufang, Achim; Schmiedt, Walther; Dueber, Christoph

    2009-01-01

    The purpose of this study was to evaluate the clinical results, complications, and secondary interventions during long-term follow-up after endovascular aneurysm repair (EVAR) and to investigate the impact of endoleak sizes on aneurysm shrinkage. From 1997 to March 2007, 127 patients (12 female, 115 male; age, 73.0 ± 7.2 years) with abdominal aortic aneurysms were treated with Talent stent-grafts. Follow-up included clinical visits, contrast-enhanced MDCT, and radiographs at 3, 6, and 12 months and then annually. Results were analyzed with respect to clinical outcome, secondary interventions, endoleak rate and management, and change in aneurysm size. There was no need for primary conversion surgery. Thirty-day mortality was 1.6% (two myocardial infarctions). Procedure-related morbidity was 2.4% (paraplegia, partial infarction of one kidney, and inguinal bleeding requiring surgery). Mean follow-up was 47.7 ± 34.2 months (range, 0-123 months). Thirty-nine patients died during follow-up; three of the deaths were related to aneurysm (aneurysm rupture due to endoleak, n = 1; secondary surgical reintervention n = 2). During follow-up, a total of 29 secondary procedures were performed in 19 patients, including 14 percutaneous procedures (10 patients) and 15 surgical procedures (12 patients), including 4 cases with late conversion to open aortic repair (stent-graft infection, n = 1; migration, endoleak, or endotension, n = 3). Overall mean survival was 84.5 ± 4.7 months. Mean survival and freedom from any event was 66.7 ± 4.5 months. MRI depicted significantly more endoleaks compared to MDCT (23.5% vs. 14.3%; P 10% of the aneurysm area were associated with reduced aneurysm shrinkage compared to no endoleaks or <10% endoleaks (Δ at 3 years, -1.8% vs. -12.0%; P < 0.05). In conclusion, endovascular aneurysm treatment with Talent stent-grafts demonstrated encouraging long-term results with moderate secondary intervention rates. Primary occlusion of all aortic side

  16. Endovascular management of acute bleeding arterioenteric fistulas

    DEFF Research Database (Denmark)

    Leonhardt, H.; Mellander, S.; Snygg, J.

    2008-01-01

    follow-up time was 3 months (range, 1-6 months). All massive bleeding was controlled by occlusive balloon catheters. Four fistulas were successfully sealed with stent-grafts, resulting in a technical success rate of 80%. One patient was circulatory stabilized by endovascular management but needed....... All had massive persistent bleeding with hypotension despite volume substitution and transfusion by the time of endovascular management. Outcome after treatment of these patients was investigated for major procedure-related complications, recurrence, reintervention, morbidity, and mortality. Mean...... arterioenteric fistulas in the emergent episode. However, in this group of patients with severe comorbidities, the risk of rebleeding is high and further intervention must be considered. Patients with cancer may only need treatment for the acute bleeding episode, and an endovascular approach has the advantage...

  17. Endovascular treatment of a true posterior communicating artery aneurysm.

    Science.gov (United States)

    Munarriz, Pablo M; Castaño-Leon, Ana M; Cepeda, Santiago; Campollo, Jorge; Alén, Jose F; Lagares, Alfonso

    2014-01-01

    Posterior communicating artery (PCoA) aneurysms are most commonly located at the junction of the internal carotid artery and the PCoA. "True" PCoA aneurysms, which originate from the PCoA itself, are rarely encountered. Most previously reported cases were treated surgically mainly before the endovascular option became available. A 53-year-old male presented with sudden onset of right hemiparesis and aphasia. Left middle cerebral artery stroke was diagnosed. Further studies revealed a 3 mm left PCoA aneurysm arising from the PCoA itself, attached to neither the internal carotid artery nor the posterior cerebral artery. Endovascular treatment was performed and the aneurysm was coiled completely. Technical advances in endovascular interventional technology have permitted an additional approach to these lesions. The possible endovascular significance of the treatment of true PCoA aneurysms is discussed.

  18. Endovascular treatment of thoracic aortic pseudoaneurysm due to brucellosis: a rare case report.

    Science.gov (United States)

    Wang, Shuai; Wang, Qi; Liu, Han; Sun, Siqiao; Sun, Xiwei; Zhang, Yang; Wang, Zhongying; Cheng, Zhihua

    2017-06-02

    Arterial damage is a known complication of brucellosis, but the occurrence of a thoracic aortic pseudoaneurysm secondary to brucellosis has not been previously reported. A 65-year-old Chinese man presented with a pseudoaneurysm in the descending segment of the thoracic aorta that caused symptoms of chest pain and intermittent fever. He was diagnosed with a thoracic aortic pseudoaneurysm secondary to brucellosis based on a positive brucella serology test (standard-tube agglutination test) and imaging examination (computed tomography angiography). Anti-brucellosis treatment and covered stent graft implantation were attempted to eliminate the brucellosis and pseudoaneurysm, respectively, and were ultimately successful, with no symptoms after 6 months of follow-up. Endovascular repair may be effective and safe for treating a thoracic aortic pseudoaneurysm resulting from brucellosis.

  19. Combined open proximal and stent-graft distal repair for distal arch aneurysms: an alternative to total debranching.

    Science.gov (United States)

    Zierer, Andreas; Sanchez, Luis A; Moon, Marc R

    2009-07-01

    We present herein a novel, combined, simultaneous open proximal and stent-graft distal repair for complex distal aortic arch aneurysms involving the descending aorta. In the first surgical step, the transverse arch is opened during selective antegrade cerebral perfusion, and a Dacron graft (DuPont, Wilmington, DE) is positioned down the descending aorta in an elephant trunk-like fashion with its proximal free margin sutured circumferentially to the aorta just distal to the left subclavian or left common carotid artery. With the graft serving as the new proximal landing zone, subsequent endovascular repair is performed antegrade during rewarming through the ascending aorta.

  20. Causes and Implications of Readmission after Abdominal Aortic Aneurysm Repair

    Science.gov (United States)

    Greenblatt, David Yu; Greenberg, Caprice C.; Kind, Amy J.H.; Havlena, Jeffrey A.; Mell, Matthew W.; Nelson, Matthew T.; Smith, Maureen A.; Kent, K. Craig

    2012-01-01

    Objective To determine the frequency, causes, predictors, and consequences of 30-day readmission after abdominal aortic aneurysm (AAA) repair. Summary Background Data CMS will soon reduce total Medicare reimbursements for hospitals with higher-than-predicted 30-day readmission rates after vascular surgical procedures including AAA repair. However, causes and factors leading to readmission in this population have never before been systematically analyzed. Methods We analyzed elective AAA repairs over a two-year period from the CMS Chronic Conditions Warehouse, a 5% national sample of Medicare beneficiaries. Results 2481 patients underwent AAA repair – 1502 endovascular (EVAR) and 979 open. 30-day readmission rates were equivalent for EVAR (13.3%) and open repair (12.8%). While wound complication was the most common reason for readmission after both procedures, the relative frequency of other causes differed – e.g., bowel obstruction was common following open repair and graft complication after EVAR. In multivariate analyses, preoperative comorbidities had a modest effect on readmission; however, postoperative factors including serious complications leading to prolonged length of stay and discharge destination other than home had a profound influence on the probability of readmission. The one-year mortality in readmitted patients was 23.4% versus 4.5% in those not readmitted (preadmission is common after AAA repair. Adjusting for comorbidities, postoperative events predict readmission, suggesting that proactively preventing, detecting, and managing postoperative complications may provide an approach to decreasing readmissions, with the potential to reduce cost and possibly enhance long-term survival. PMID:22964736

  1. New aspects of fenestrated vasculature and tissue dynamics in the sensory circumventricular organs of adult brains

    Directory of Open Access Journals (Sweden)

    Seiji eMiyata

    2015-10-01

    Full Text Available The blood–brain barrier (BBB generally consists of endothelial tight junction barriers that prevent the free entry of blood-derived substances, thereby maintaining the extracellular environment of the brain. However, the circumventricular organs (CVOs, which are located along the midlines of the brain ventricles, lack these endothelial barriers and have fenestrated capillaries; therefore, they have a number of essential functions, including the transduction of information between the blood circulation and brain. Previous studies have demonstrated the extensive contribution of the CVOs to body fluid and thermal homeostasis, energy balance, the chemoreception of blood-derived substances, and neuroinflammation. In this review, recent advances have been discussed in fenestrated capillary characterization and dynamic tissue reconstruction accompanied by angiogenesis and neurogliogenesis in the sensory CVOs of adult brains. The sensory CVOs, including the organum vasculosum of the lamina terminalis (OVLT, subfornical organ (SFO, and area postrema (AP, have size-selective and heterogeneous vascular permeabilities. Astrocyte-/tanycyte-like neural stem cells (NSCs sense blood- and cerebrospinal fluid-derived information through the transient receptor potential vanilloid 1, a mechanical/osmotic receptor, Toll-like receptor 4, a lipopolysaccharide receptor, and Nax, a Na-sensing Na channel. They also express tight junction proteins and densely and tightly surround mature neurons to protect them from blood-derived neurotoxic substances, indicating that the NSCs of the CVOs perform BBB functions while maintaining the capacity to differentiate into new neurons and glial cells. In addition to neurogliogenesis, the density of fenestrated capillaries is regulated by angiogenesis, which is accompanied by the active proliferation and sprouting of endothelial cells. Vascular endothelial growth factor (VEGF signaling may be involved in angiogenesis and

  2. Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: a comparison with computed tomography aortography.

    LENUS (Irish Health Repository)

    Manning, Brian J

    2012-02-01

    OBJECTIVES: Cumulative radiation dose, cost, and increased demand for computed tomography aortography (CTA) suggest that duplex ultrasonography (DU) may be an alternative to CTA-based surveillance. We compared CTA with DU during endovascular aneurysm repair (EVAR) follow-up. METHODS: Patients undergoing EVAR had clinical and radiological follow-up data entered in a prospectively maintained database. For the purpose of this study, the gold standard test for endoleak detection was CTA, and an endoleak detected on DU alone was assumed to be a false positive result. DU interpretation was performed independently of CTA and vice versa. RESULTS: One hundred thirty-two patients underwent EVAR, of whom 117 attended for follow-up ranging from six months to nine years (mean, 32 months). Adequate aneurysm sac visualisation on DU was not possible in 1.7% of patients, predominantly due to obesity. Twenty-eight endoleaks were detected in 28 patients during follow-up. Of these, 24 were initially identified on DU (four false negative DU examinations), and eight had at least one negative CTA with a positive DU prior to diagnosis. Twenty-three endoleaks were type II in nature and three of these patients had increased sac size. There was one type I and four type III endoleaks. Two of these (both type III) had an increased sac size. Of 12 patients with increased aneurysm size of 5 mm or more at follow-up, five had an endoleak visible on DU, yet negative CTA and a further five had endoleak visualisation on both DU and CTA. Of six endoleaks which underwent re-intervention, all were initially picked up on DU. One of these endoleaks was never demonstrated on CTA and a further two had at least one negative CTA prior to endoleak confirmation. Positive predictive value for DU was 45% and negative predictive value 94%. Specificity of DU for endoleak detection was 67% when compared with CTA, because of the large number of false positive DU results. Sensitivity for DU was 86%, with all

  3. New ways of looking at very small holes - using optical nanoscopy to visualize liver sinusoidal endothelial cell fenestrations

    Science.gov (United States)

    Øie, Cristina I.; Mönkemöller, Viola; Hübner, Wolfgang; Schüttpelz, Mark; Mao, Hong; Ahluwalia, Balpreet S.; Huser, Thomas R.; McCourt, Peter

    2018-02-01

    Super-resolution fluorescence microscopy, also known as nanoscopy, has provided us with a glimpse of future impacts on cell biology. Far-field optical nanoscopy allows, for the first time, the study of sub-cellular nanoscale biological structures in living cells, which in the past was limited to electron microscopy (EM) (in fixed/dehydrated) cells or tissues. Nanoscopy has particular utility in the study of "fenestrations" - phospholipid transmembrane nanopores of 50-150 nm in diameter through liver sinusoidal endothelial cells (LSECs) that facilitate the passage of plasma, but (usually) not blood cells, to and from the surrounding hepatocytes. Previously, these fenestrations were only discernible with EM, but now they can be visualized in fixed and living cells using structured illumination microscopy (SIM) and in fixed cells using single molecule localization microscopy (SMLM) techniques such as direct stochastic optical reconstruction microscopy. Importantly, both methods use wet samples, avoiding dehydration artifacts. The use of nanoscopy can be extended to the in vitro study of fenestration dynamics, to address questions such as the following: are they actually dynamic structures, and how do they respond to endogenous and exogenous agents? A logical further extension of these methodologies to liver research (including the liver endothelium) will be their application to liver tissue sections from animal models with different pathological manifestations and ultimately to patient biopsies. This review will cover the current state of the art of the use of nanoscopy in the study of liver endothelium and the liver in general. Potential future applications in cell biology and the clinical implications will be discussed.

  4. Role of graft oversizing in the fixation strength of barbed endovascular grafts.

    Science.gov (United States)

    Kratzberg, Jarin A; Golzarian, Jafar; Raghavan, Madhavan L

    2009-06-01

    The role of endovascular graft oversizing on risk of distal graft migration following endovascular aneurysm repair for abdominal aortic aneurysm is poorly understood. A controlled in vitro investigation of the role of oversizing in graft-aorta attachment strength for endovascular grafts (EVGs) with barbs was performed. Barbed stent grafts (N = 20) with controlled graft oversizing varying from 4-45% were fabricated while maintaining other design variables unchanged. A flow loop with physiological flow characteristics and a biosynthetic aortic aneurysm phantom (synthetic aneurysm model with a bovine aortic neck) were developed. The stent grafts were deployed into the aortic neck of the bio-synthetic aortic aneurysm phantom under realistic flow conditions. Computed tomography imaging of the graft-aorta complex was used to document attachment characteristics such as graft apposition, number of barbs penetrated, and penetration depth and angle. The strength of graft attachment to the aortic neck was assessed using mechanical pullout testing. Stent grafts were categorized into four groups based on oversizing: 4-10%; 11-20%; 21-30%; and greater than 30% oversizing. Pullout force, a measure of post-deployment fixation strength was not different between 4-10% (6.23 +/- 1.90 N), 11-20% (6.25 +/- 1.84 N) and 20-30% (5.85 +/- 1.89 N) groups, but significantly lower for the group with greater than 30% oversizing (3.67 +/- 1.41 N). Increasing oversizing caused a proportional decrease in the number of barbs penetrating the aortic wall (correlation = -0.83). Of the 14 barbs available in the stent graft, 89% of the barbs (12.5 of 14 on average) penetrated the aortic wall in the 4-10% oversizing group while only 38% (5.25 of 14) did for the greater than 30% group (P barb penetration were found to be positively correlated to pullout force. Greater than 30% graft oversizing affects both barb penetration and graft apposition adversely resulting in a low pullout force in this in vitro

  5. Emergency endovascular coiling of a ruptured giant splenic artery aneurysm

    DEFF Research Database (Denmark)

    Wernheden, Erika; Brenøe, Anne Sofie; Shahidi, Saeid

    2017-01-01

    Splenic artery aneurysms (SAAs) are the third most common abdominal aneurysm. Endovascular treatment of SAAs is preferred, and coiling is the most commonly used technique. Ruptured giant (>5 cm) SAAs are usually treated with open surgery including splenectomy. We present a rare case of a ruptured...... 15-cm giant SAA in an 84-year-old woman treated successfully with emergency endovascular coiling. To our knowledge, this is one of the few reports of emergency endovascular treatment for ruptured giant SAA....

  6. Early endovascular treatment of superior mesenteric occlusion secondary to thromboemboli.

    Science.gov (United States)

    Jia, Z; Jiang, G; Tian, F; Zhao, J; Li, S; Wang, K; Wang, Y; Jiang, L; Wang, W

    2014-02-01

    To evaluate our early experience with endovascular revascularization in patients with acute thromboembolic occlusion of the superior mesenteric artery (SMA). A retrospective review was conducted of all patients who underwent endovascular revascularization for acute thromboembolic SMA occlusion from May 2005 to May 2012. Endovascular revascularization was performed using aspiration, intra-arterial thrombolysis, and adjunctive stent-placement techniques. Laparotomy was performed if the patient developed clinical signs of advanced bowel ischemia after endovascular procedure. Twenty-one patients underwent endovascular revascularization for acute thromboembolic SMA occlusion. All presented with acute-onset abdominal pain. Three patients had rebound tenderness before the procedure. Computed tomography angiography revealed complete occlusion in seven cases and incomplete occlusion in 14 cases, with no evidence of free gas or bowel necrosis. The median duration from onset of symptoms to revascularization was 8.7 ± 4.1 hours (range, 2-18 hours). Completely successful endovascular revascularization occurred in six cases (aspiration alone, 3 cases; combined aspiration and urokinase, 3 cases); partial success was achieved in 15 cases (aspiration alone, 4 cases; combined aspiration and urokinase, 10 cases; and combined aspiration, urokinase, and stent placement, 1 case). Laparotomy was required in five patients, all of whom had SMA main trunk complete occlusion and required small bowel resection. The 30-day mortality for all patients was 9.5%. During a median follow-up of 26 months, 15 patients remained asymptomatic, three patients reported occasional abdominal pain, and one patient had temporary short-bowel syndrome. Percutaneous revascularization is a promising alternative to surgery for acute SMA occlusion in selected patients who have no signs of advanced bowel ischemia. Early diagnosis followed by prompt endovascular intervention with close postprocedural monitoring is

  7. Endovascular Treatment Strategies in Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Ozkan, Ugur; Oguzkurt, Levent; Tercan, Fahri; Gumus, Burcak

    2009-01-01

    The aim of this study was to report our experience in endovascular treatment of total aortoiliac occlusion. Five patients who underwent endovascular recanalization procedures including manual aspiration thrombectomy, balloon angioplasty, and stent placement for total aortoiliac occlusion in a 4-year period were reviewed retrospectively. The mean age of patients was 51 years (range, 43 to 58 years). All patients had abdominal aorta and bilateral common iliac artery occlusion with or without external iliac artery occlusion. All patients either had a contraindication to surgery or refused it. Initial technical success was obtained in four of five (80%) patients. Endovascular techniques were successful in four patients who had good distal runoff and short-segment aortoiliac occlusion, but failed in a patient who had the worst distal runoff and long-segment aortoiliac occlusion. We observed two major complications, one of which was bilateral rupture of the common iliac arteries treated with covered stent placement. Another patient had extension of intra-aortic thrombus into the iliac stent after primary stenting. This was successfully treated with manual aspiration thrombectomy. Aortic and iliac stents remained patent during the follow-up period (median, 18 months; range, 3 to 26 months) in four patients. Primary patency rates at 6, 12, and 24 months were all 80%. In conclusion, endovascular treatment can be an alternative for aortoiliac occlusion in selected patients. Short- to midterm follow-up so far is satisfactory. Removal of intra-aortic thrombus with manual aspiration thrombectomy before balloon angioplasty and/or stenting is possible and a good alternative to thrombolysis.

  8. Endovascular treatment of cerebral aneurysms - a cost analysis | Le ...

    African Journals Online (AJOL)

    The average cost for endovascular treatment per patient was R37 041. Surgical treatment was more expensive at R44 104, a difference of 16%. Conclusions. Despite the high cost of endovascular devices, appropriate use of this technology ultimately offers less expensive treatment than microsurgical clipping of aneurysms.

  9. Acute Symptomatic Abdominal Aortic Aneurysm Secondary to Endovascular Stent Graft Associated Type II Endoleak

    Directory of Open Access Journals (Sweden)

    Karen Ka Leung Chan

    2006-07-01

    Full Text Available Endovascular abdominal aneurysm repair (EVAR is popular because of its low invasiveness and feasibility for high-risk patients. Endoleak is common after EVAR and is characterized by blood flow within the aneurysm sac but outside the stent graft. Type II or collateral endoleak commonly results from retrograde filling of the aneurysm from collateral visceral vessels, lumbar, inferior mesenteric, accessory renal or sacral arteries. Collateral leaks are generally thought to be benign and over half of the early leaks will seal spontaneously. Sporadically, collateral endoleak could lead to aneurysm sac pressurization and place the patient at ongoing risk of rupture. Herein, we report an uncommon case of early post-stent graft placement symptomatic abdominal aortic aneurysm associated with type II endoleak.

  10. Emergency endovascular coiling of a ruptured giant splenic artery aneurysm

    Directory of Open Access Journals (Sweden)

    Erika Wernheden, MD

    2017-12-01

    Full Text Available Splenic artery aneurysms (SAAs are the third most common abdominal aneurysm. Endovascular treatment of SAAs is preferred, and coiling is the most commonly used technique. Ruptured giant (>5 cm SAAs are usually treated with open surgery including splenectomy. We present a rare case of a ruptured 15-cm giant SAA in an 84-year-old woman treated successfully with emergency endovascular coiling. To our knowledge, this is one of the few reports of emergency endovascular treatment for ruptured giant SAA.

  11. Standards for Endovascular Neurosurgical Training and Certification of the Society of Korean Endovascular Neurosurgeons 2013

    Science.gov (United States)

    Shin, Dong-Seong; Park, Sukh-Que; Kang, Hyun-Seung; Yoon, Seok-Mann; Cho, Jae-Hoon; Lim, Dong-Jun; Baik, Min-Woo; Kwon, O Ki

    2014-01-01

    The need for standard endovascular neurosurgical (ENS) training programs and certification in Korea cannot be overlooked due to the increasing number of ENS specialists and the expanding ENS field. The Society of Korean Endovascular Neurosurgeons (SKEN) Certification Committee has prepared training programs and certification since 2010, and the first certificates were issued in 2013. A task force team (TFT) was organized in August 2010 to develop training programs and certification. TFT members researched programs and systems in other countries to develop a program that best suited Korea. After 2 years, a rough draft of the ENS training and certification regulations were prepared, and the standard training program title was decided. The SKEN Certification Committee made an official announcement about the certification program in March 2013. The final certification regulations comprised three major parts: certified endovascular neurosurgeons (EN), certified ENS institutions, and certified ENS training institutions. Applications have been evaluated and the results were announced in June 2013 as follows: 126 members received EN certification and 55 hospitals became ENS-certified institutions. The SKEN has established standard ENS training programs together with a certification system, and it is expected that they will advance the field of ENS to enhance public health and safety in Korea. PMID:24851145

  12. Delayed endovascular aortic repair is associated with reduced in-hospital mortality in patients with blunt thoracic aortic injury.

    Science.gov (United States)

    Marcaccio, Christina L; Dumas, Ryan P; Huang, Yanlan; Yang, Wei; Wang, Grace J; Holena, Daniel N

    2018-02-13

    The traditional approach to stable blunt thoracic aortic injury (BTAI) endorsed by the Society for Vascular Surgery is early (<24 hours) thoracic endovascular aortic repair (TEVAR). Recently, some studies have shown improved mortality in stable BTAI patients repaired in a delayed manner (≥24 hours). However, the indications for use of delayed TEVAR for BTAI are not well characterized, and its overall impact on the patient's survival remains poorly understood. We sought to determine whether delayed TEVAR is associated with a decrease in mortality compared with early TEVAR in this population. We conducted a retrospective cohort study of adult patients with BTAI (International Classification of Diseases, Ninth Revision diagnosis code 901.0) who underwent TEVAR (International Classification of Diseases, Ninth Revision procedure code 39.73) from 2009 to 2013 using the National Sample Program data set. Missing physiologic data were imputed using chained multiple imputation. Patients were parsed into groups based on the timing of TEVAR (early, <24 hours, vs delayed, ≥24 hours). The χ 2 , Mann-Whitney, and Fisher exact tests were used to compare baseline characteristics and outcomes of interest between groups. Multivariable logistic regression for mortality was performed that included all variables significant at P ≤ .2 in univariate analyses. A total of 2045 adult patients with BTAI were identified, of whom 534 (26%) underwent TEVAR. Patients with missing data on TEVAR timing were excluded (n = 27), leaving a total of 507 patients for analysis (75% male; 69% white; median age, 40 years [interquartile range, 27-56 years]; median Injury Severity Score [ISS], 34 [interquartile range, 26-41]). Of these, 378 patients underwent early TEVAR and 129 underwent delayed TEVAR. The two groups were similar with regard to age, sex, race, ISS, and presenting physiology. Mortality was 11.9% in the early TEVAR group vs 5.4% in the delayed group, with the early group

  13. Potential Long-Term Complications of Endovascular Stent Grafting for Blunt Thoracic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Larry E. Miller

    2012-01-01

    Full Text Available Blunt thoracic aortic injury (BTAI is a rare, but lethal, consequence of rapid deceleration events. Most victims of BTAI die at the scene of the accident. Of those who arrive to the hospital alive, expedient aortic intervention significantly improves survival. Thoracic endovascular aortic repair (TEVAR has been accepted as the standard of care for BTAI at many centers, primarily due to the convincing evidence of lower mortality and morbidity in comparison to open surgery. However, less attention has been given to potential long-term complications of TEVAR for BTAI. This paper focuses on these complications, which include progressive aortic expansion with aging, inadequate stent graft characteristics, device durability concerns, long-term radiation exposure concerns from follow-up computed tomography scans, and the potential for (Victims of Modern Imaging Technology VOMIT.

  14. Perioperative complications in endovascular neurosurgery: Anesthesiologist's perspective

    Science.gov (United States)

    Sharma, Megha U.; Ganjoo, Pragati; Singh, Daljit; Tandon, Monica S.; Agarwal, Jyotsna; Sharma, Durga P.; Jagetia, Anita

    2017-01-01

    Background: Endovascular neurosurgery is known to be associated with potentially serious perioperative complications that can impact the course and outcome of anesthesia. We present here our institutional experience in the anesthetic management of various endovascular neurosurgical procedures and their related complications over a 10-year period. Methods: Data was obtained in 240 patients pertaining to their preoperative status, details of anesthesia and surgery, perioperative course and surgery-related complications. Information regarding hemodynamic alterations, temperature variability, fluid-electrolyte imbalance, coagulation abnormalities and alterations in the anesthesia course was specifically noted. Results: Among the important complications observed were aneurysm rupture (2.5%), vasospasm (6.67%), thromboembolism (4.16%), contrast reactions, hemodynamic alterations, electrolyte abnormalities, hypothermia, delayed emergence from anesthesia, groin hematomas and early postoperative mortality (5.14%). Conclusion: Awareness of the unique challenges of endovascular neurosurgery and prompt and appropriate management of the associated complications by an experienced neuroanesthesiologist is vital to the outcome of these procedures. PMID:28413524

  15. Endovascular repair of primary retrograde Stanford type A aortic dissection%腔内修复术治疗原发性逆撕型Stanford A型主动脉夹层

    Institute of Scientific and Technical Information of China (English)

    吴海卫; 孙磊; 李德闽; 景华; 许飚; 王常田; 张雷

    2016-01-01

    Objective To summarize the short-and mid-term results on endovascular repair of primary retrograde Stanford type A aortic dissection with an entry tear in distal aortic arch or descending aorta.Methods Between December 2009 and December 2014,21 male patients of primary retrograde Stanford type A aortic dissection with a mean age of (52 ± 9) years received endovascular repair in Department of Cardiothoracic Surgery,Jinling Hospital.Among the 21 cases,17 patients were presented as ascending aortic intramural hematoma,4 patients as active blood flow in false lumen and partial thrombosis,8 patients as ulcer on descending aorta combined intramural hematoma in descending aorta,and 13 patients as typical dissection changes.All patients received cndovascular stent-graft repair successfully,with 15 cases in acute phase and 6 cases in chronic phase.Results Cone stent was implanted in 13 cases,while straight stent in 8 cases,including 1 case of left common carotid-left subclavian artery bypass surgery and 1 case of restrictive bare-metal stent implantation.No perioperative stroke,paraplegia,stent fracture or displacement,limbs or abdominal organ ischemia or other severe complications occured,except for tracheotomy in 2 patients.Active blood flow in ascending aorta or aortic arch disappeared,and intramural hematoma started being absorbed on CT angiography images before discharge.All patients were alive during follow-up (6 to 72 months),and intramural hematoma in ascending aorta and aortic arch was absorbed thoroughly.Type Ⅰ endoleak and ulcer expansion were found in 1 patient,and type Ⅳ endoleak in distal stent was found in another one patient.Secondary ascending aortic dissection was found in 1 case two years later,which was cured by hybrid procedure with cardiopulmonary bypass.Conclusion Endovascular repair of primary retrograde Stanford type A aortic dissection was safe and effective,which correlated with favorable short-and mid-term results.%目的

  16. Endovascular stents: a review of their use in peripheral arterial disease.

    Science.gov (United States)

    Kudagi, Vinod S; White, Christopher J

    2013-06-01

    Technological advances in the past decade have shifted revascularization strategies from traditional open surgical approaches toward lower-morbidity percutaneous endovascular treatments for patients with lower extremity peripheral arterial disease (PAD). The continuing advances in stent design, more than any other advances, have fueled the growth of catheter-based procedures by improving the safety, durability, and predictability of percutaneous revascularization. Although the 2007 TransAtlantic Inter-Society Consensus (TASC) guidelines recommend endovascular therapy for type A and B aortoiliac and femoropopliteal lesions, recent developments in stent technology and increased experience of interventionists have suggested that a strategy of endovascular therapy first is appropriate in experienced hands for TASC type D lesions. The role of endovascular interventions is also expanding in the treatment of limb-threatening ischemia.

  17. Imaging Evaluation of the Location and Fenestration of Sellar Floor during Endonasal Transsphenoidal Surgery in Patients with Pituitary Adenomas.

    Science.gov (United States)

    Wang, Shousen; Qin, Yong; Xiao, Deyong; Wu, Zhifeng; Wei, Liangfeng

    2018-05-03

    To evaluate the clinical value of three-dimensional (3D) CT reconstruction of the sphenoidal sinus separation in localizing sellar floor during endonasal transsphenoidal surgery, and determine the size and location of sellar floor fenestration. After exclusion,51 patients were eligible for study inclusion. A pre-operative CT scan of the paranasal sinus and CT scan and MRI of the pituitary gland were obtained. Sphenoidal sinus separation was reconstructed using Mimics 15.0 software and the quantity, shape, and orientation were observed and compared with intra-operative data, the purpose of which was to guide the localization of sellar floor. Anatomic variation of the sphenoidal sinus and adjacent structures, tumor and sella turcica morphology, minimal distance between the cavernous segment of the internal carotid artery(CSICA) bilaterally, and the shortest distance from the midline were measured. Based upon the shape of the sphenoidal sinus separation, sellar floor was accurately localized in all cases. Intra-operative sphenoidal sinus separation was consistent with pre-operative 3D CT reconstruction images. The sellar floor was extremely small in two patients, and insufficient fenestration of the sellar floor negatively affected tumor resection. Pre-operative 3D CT reconstruction is helpful for accurate and rapid localization of the saddle floor. The anatomic variation of sphenoidal sinus and adjacent structures, the characteristics of tumor and Sella, the minimum distance between bilateral CSICA and the shortest distance from the midline are helpful for the establishment of individualized Sellar bottom fenestration. Copyright © 2018. Published by Elsevier Inc.

  18. Modern radiosurgical and endovascular classification schemes for brain arteriovenous malformations.

    Science.gov (United States)

    Tayebi Meybodi, Ali; Lawton, Michael T

    2018-05-04

    Stereotactic radiosurgery (SRS) and endovascular techniques are commonly used for treating brain arteriovenous malformations (bAVMs). They are usually used as ancillary techniques to microsurgery but may also be used as solitary treatment options. Careful patient selection requires a clear estimate of the treatment efficacy and complication rates for the individual patient. As such, classification schemes are an essential part of patient selection paradigm for each treatment modality. While the Spetzler-Martin grading system and its subsequent modifications are commonly used for microsurgical outcome prediction for bAVMs, the same system(s) may not be easily applicable to SRS and endovascular therapy. Several radiosurgical- and endovascular-based grading scales have been proposed for bAVMs. However, a comprehensive review of these systems including a discussion on their relative advantages and disadvantages is missing. This paper is dedicated to modern classification schemes designed for SRS and endovascular techniques.

  19. Three-dimensional (3D) printed endovascular simulation models: a feasibility study.

    Science.gov (United States)

    Mafeld, Sebastian; Nesbitt, Craig; McCaslin, James; Bagnall, Alan; Davey, Philip; Bose, Pentop; Williams, Rob

    2017-02-01

    Three-dimensional (3D) printing is a manufacturing process in which an object is created by specialist printers designed to print in additive layers to create a 3D object. Whilst there are initial promising medical applications of 3D printing, a lack of evidence to support its use remains a barrier for larger scale adoption into clinical practice. Endovascular virtual reality (VR) simulation plays an important role in the safe training of future endovascular practitioners, but existing VR models have disadvantages including cost and accessibility which could be addressed with 3D printing. This study sought to evaluate the feasibility of 3D printing an anatomically accurate human aorta for the purposes of endovascular training. A 3D printed model was successfully designed and printed and used for endovascular simulation. The stages of development and practical applications are described. Feedback from 96 physicians who answered a series of questions using a 5 point Likert scale is presented. Initial data supports the value of 3D printed endovascular models although further educational validation is required.

  20. Correção endovascular de persistência do conduto arterioso em paciente adulto Endovascular approach for persistent ductus arteriosus closure in adult patient

    Directory of Open Access Journals (Sweden)

    José Carlos Dorsa Vieira Pontes

    2010-03-01

    Full Text Available O tratamento da Persistência do Canal Arterial (PCA, em adultos, ainda é controverso. A utilização de próteses auto-expansíveis tem-se mostrado como uma alternativa eficaz ao tratamento cirúrgico. Apresentamos um caso de uma paciente de 45 anos submetida ao tratamento endovascular com o uso de stent auto-expansível.The treatment for closure of persistent ductus arteriosus (PDA in adults still controversial. The endovascular approach has been shown as an effective alternative to surgical treatment. We report a case of 45 years old pacient submitted to endovascular approach for PDA closure.

  1. Endovascular Neurosurgery: Personal Experience and Future Perspectives.

    Science.gov (United States)

    Raymond, Jean

    2016-09-01

    From Luessenhop's early clinical experience until the present day, experimental methods have been introduced to make progress in endovascular neurosurgery. A personal historical narrative, spanning the 1980s to 2010s, with a review of past opportunities, current problems, and future perspectives. Although the technology has significantly improved, our clinical culture remains a barrier to methodologically sound and safe innovative care and progress. We must learn how to safely practice endovascular neurosurgery in the presence of uncertainty and verify patient outcomes in real time. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Select early type IA endoleaks after endovascular aneurysm repair will resolve without secondary intervention.

    Science.gov (United States)

    O'Donnell, Thomas F X; Corey, Michael R; Deery, Sarah E; Tsougranis, Gregory; Maruthi, Rohit; Clouse, W Darrin; Cambria, Richard P; Conrad, Mark F

    2018-01-01

    Although it is traditionally considered ominous, the natural history of early proximal attachment site endoleaks (IA) after endovascular aneurysm repair (EVAR) is not well known. Our aim was to identify risk factors for persistent type IA endoleaks and to determine their effect on long-term outcomes after EVAR. All patients who underwent infrarenal EVAR at a single institution between 1998 and 2015 were identified. Preoperative axial imaging and intraoperative arteriograms were reviewed, and those patients with a type IA endoleak were further studied. Aneurysm features were characterized by two reviewers and were studied for predictors of persistent endoleaks at the conclusion of the case. Patient records and the Social Security Death Index were used to record 1-year and overall survival. We identified 1484 EVARs, 122 (8%) of which were complicated by a type IA endoleak on arteriography after graft deployment, with a median follow-up of 4 years. The majority of patients underwent additional ballooning of the proximal site (52 [43%]) or placement of an aortic cuff (47 [39%]); 30 patients (25%) received a Palmaz stent, and four patients were treated with coils or anchors. At case end, only 43 (35%) of the type IA endoleaks remained; at 1 month, only 16 endoleaks persisted (13%), and only six persisted at 1 year (6%). In multivariable analysis, the only independent predictor of persistence of type IA endoleak at the conclusion of the case was the presence of extensive neck calcifications (odds ratio [OR], 9.9; 95% confidence interval [CI], 1.4-67.9; P = .02). Thirteen patients (11%) underwent reintervention for type IA endoleaks, with a time frame ranging from 3 days postoperatively to 11 years. There were three patients (2.4%) who experienced aneurysm rupture. Postoperative type IA endoleak was associated with lower survival at 1 year (79% vs 91%; relative risk, 2.5; 95% CI, 1.1-5.4; P = .02), but it did not affect long-term survival (log-rank, P = .45

  3. Endovascular Versus Open Surgical Intervention in Patients with Takayasu's Arteritis: A Meta-analysis.

    Science.gov (United States)

    Jung, Jae Hyun; Lee, Young Ho; Song, Gwan Gyu; Jeong, Han Saem; Kim, Jae-Hoon; Choi, Sung Jae

    2018-06-01

    Although medical treatment has advanced, surgical treatment is needed to control symptoms of Takayasu's arteritis (TA), such as angina, stroke, hypertension, or claudication. Endovascular or open surgical intervention is performed; however, there are few comparative studies on these methods. This meta-analysis and systematic review aimed to examine the outcome of surgical treatment of TA. A meta-analysis comparing outcomes of endovascular and open surgical intervention was performed using MEDLINE and Embase. This meta-analysis included only observational studies, and the evidence level was low to moderate. Data were pooled and analysed using a fixed or random effects model with the I 2 statistic. The included studies involved a total of 770 patients and 1363 lesions, with 389 patients treated endovascularly and 420 treated by surgical revascularization. Restenosis was more common with endovascular than open surgical intervention (odds ratio [OR] 5.18, 95% confidence interval [CI] 2.78-9.62; p open surgical intervention patients in the coronary artery, supra-aortic branches, and renal artery. In both the active and inactive stages, restenosis was more common in those treated endovascularly than in those treated by open surgery. However, stroke occurred less often with endovascular intervention than with open surgical intervention (OR 0.33, 95% CI 0.12-0.90; p = .003). Mortality and complications other than stroke and mortality did not differ between endovascular and open surgical intervention. This meta-analysis has shown a lower risk of restenosis with open surgical intervention than with endovascular intervention. Stroke was generally more common with open surgical intervention than with endovascular intervention. However, there were differences according to the location of the lesion, and the risk of stroke in open surgery is higher when the supra-aortic branches are involved rather than the renal arteries. Copyright © 2018 European Society for Vascular

  4. Utility of gadolinium as a contrast medium in endovascular therapeutic procedures; Utilidad del gadolinio como medio de contraste en procedimientos terapeuticos endovasculares

    Energy Technology Data Exchange (ETDEWEB)

    Reyes, R.; Pardo, M. D.; Gorriz, E.; Gallardo, L. (Hospital de Gran Canaria Dr. Negrin); Carreira, J. M. (Universidad de Santiago de Compostela)

    2001-07-01

    To assess the utility of gadolinium associated with CO{sub 2}, as a contrast medium in angiographic studies related to endovascular therapeutic procedures in patients with suboptimal renal function. Between January 2000 and June 2001, endovascular treatments using CO{sub 2} and gadolinium as contrast medium were performed in 10 patients presenting renal function deterioration (creatinine>1.5 mg/ml). A mean dose of 42 ml of gadolinium was administered. The images acquired in diagnostic and therapeutic studied were satisfactory in every case. There was no evidence of significant increases in the previous urea and creatine levels when measured 24, 48 and 72 hours after the procedure. In combination with CO{sub 2} gadolinium is a useful contrast medium for endovascular therapeutic procedures in patients with suboptimal renal function. (Author) 21 refs.

  5. Content Validation and Evaluation of an Endovascular Teamwork Assessment Tool.

    Science.gov (United States)

    Hull, L; Bicknell, C; Patel, K; Vyas, R; Van Herzeele, I; Sevdalis, N; Rudarakanchana, N

    2016-07-01

    To modify, content validate, and evaluate a teamwork assessment tool for use in endovascular surgery. A multistage, multimethod study was conducted. Stage 1 included expert review and modification of the existing Observational Teamwork Assessment for Surgery (OTAS) tool. Stage 2 included identification of additional exemplar behaviours contributing to effective teamwork and enhanced patient safety in endovascular surgery (using real-time observation, focus groups, and semistructured interviews of multidisciplinary teams). Stage 3 included content validation of exemplar behaviours using expert consensus according to established psychometric recommendations and evaluation of structure, content, feasibility, and usability of the Endovascular Observational Teamwork Assessment Tool (Endo-OTAS) by an expert multidisciplinary panel. Stage 4 included final team expert review of exemplars. OTAS core team behaviours were maintained (communication, coordination, cooperation, leadership team monitoring). Of the 114 OTAS behavioural exemplars, 19 were modified, four removed, and 39 additional endovascular-specific behaviours identified. Content validation of these 153 exemplar behaviours showed that 113/153 (73.9%) reached the predetermined Item-Content Validity Index rating for teamwork and/or patient safety. After expert team review, 140/153 (91.5%) exemplars were deemed to warrant inclusion in the tool. More than 90% of the expert panel agreed that Endo-OTAS is an appropriate teamwork assessment tool with observable behaviours. Some concerns were noted about the time required to conduct observations and provide performance feedback. Endo-OTAS is a novel teamwork assessment tool, with evidence for content validity and relevance to endovascular teams. Endo-OTAS enables systematic objective assessment of the quality of team performance during endovascular procedures. Copyright © 2016. Published by Elsevier Ltd.

  6. Endovascular therapy options in femoro-popliteal PAD; Endovaskulaere Therapieoptionen bei femoropoplitealer pAVK

    Energy Technology Data Exchange (ETDEWEB)

    Brechtel, Klaus [Universitaetsklinikum Tuebingen (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie

    2010-09-15

    The endovascular treatment of femoro-popliteal PAD is still challenging. The number of endovascular procedures in this vessel segment has increased over the past years. Despite new technologies, the outcome of endovascular therapy in terms of durability is still weak. In the meantime, the latest developments are progressing, such as the combination of mechanical angioplasty and drug delivery. Additionally, there are former techniques, such as debulking by atherectomy, which have been technically improved and now contribute to modern concepts of endovascular treatment. This article provides an overview on treatment indications and technical options including the latest technical developments. (orig.)

  7. A comparison of Percutaneous femoral access in Endovascular Repair versus Open femoral access (PiERO): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Vierhout, Bastiaan P; Saleem, Ben R; Ott, Alewijn; van Dijl, Jan Maarten; de Kempenaer, Ties D van Andringa; Pierie, Maurice E N; Bottema, Jan T; Zeebregts, Clark J

    2015-09-14

    Access for endovascular repair of abdominal aortic aneurysms (EVAR) is obtained through surgical cutdown or percutaneously. The only devices suitable for percutaneous closure of the 20 French arteriotomies of the common femoral artery (CFA) are the Prostar(™) and Proglide(™) devices (Abbott Vascular). Positive effects of these devices seem to consist of a lower infection rate, and shorter operation time and hospital stay. This conclusion was published in previous reports comparing techniques in patients in two different groups (cohort or randomized). Access techniques were never compared in one and the same patient; this research simplifies comparison because patient characteristics will be similar in both groups. Percutaneous access of the CFA is compared to surgical cutdown in a single patient; in EVAR surgery, access is necessary in both groins in each patient. Randomization is performed on the introduction site of the larger main device of the endoprosthesis. The contralateral device of the endoprosthesis is smaller. When we use this type of randomization, both groups will contain a similar number of main and contralateral devices. Preoperative nose cultures and perineal cultures are obtained, to compare colonization with postoperative wound cultures (in case of a surgical site infection). Furthermore, patient comfort will be considered, using VAS-scores (Visual analog scale). Punch biopsies of the groin will be harvested to retrospectively compare skin of patients who suffered a surgical site infection (SSI) to patients who did not have an SSI. The PiERO trial is a multicenter randomized controlled clinical trial designed to show the consequences of using percutaneous access in EVAR surgery and focuses on the occurrence of surgical site infections. NTR4257 10 November 2013, NL44578.042.13.

  8. Carbon dioxide (CO2) angiography as an option for endovascular abdominal aortic aneurysm repair (EVAR) in patients with chronic kidney disease (CKD).

    Science.gov (United States)

    De Angelis, Chiara; Sardanelli, Francesco; Perego, Matteo; Alì, Marco; Casilli, Francesco; Inglese, Luigi; Mauri, Giovanni

    2017-11-01

    To assess feasibility, efficacy and safety of carbon dioxide (CO 2 ) digital subtraction angiography (DSA) to guide endovascular aneurysm repair (EVAR) in a cohort of patients with chronic kidney disease (CKD). After Ethical Committee approval, the records of 13 patients (all male, mean age 74.6 ± 8.0 years) with CKD, who underwent EVAR to exclude an abdominal aortic aneurysm (AAA) under CO 2 angiography guidance, were reviewed. The AAA to be excluded had a mean diameter of 52.0 ± 8.0 mm. CO 2 angiography was performed by automatic (n = 7) or hand (n = 6) injection. The endograft was correctly placed and the AAA was excluded in all cases, without any surgical conversions. Two patients (15.4%) had an endoleak: one type-Ia, detected by CO 2 -DSA and effectively treated with prosthesis dilatation; one type-III, detected by CO 2 -DSA, confirmed using 10 ml of ICM, and conservatively managed. In one patient, CO 2 angiograms were considered of too low quality for guiding the procedure and 200 ml of ICM were administered. Overall, 11 patients (84.6%) underwent a successful EVAR under the guidance of the sole CO 2 angiography. No patients suffered from major complications, including those typically CO 2 -related. Two patients suffered from abdominal pain during the procedure secondary to a transient splanchnic perfusion's reduction due to CO 2 , and one patient had a worsening of renal function probably caused by a cholesterol embolization during the procedure. In patients with CKD, EVAR under CO 2 angiography guidance is feasible, effective, and safe.

  9. The preparation of teaching simulation system of endovascular intervention

    International Nuclear Information System (INIS)

    Li Yiming; Wang Jie; Shi Haibin; Jin Xijun

    2011-01-01

    Objective: To establish a teaching simulation system of endovascular intervention and to evaluate its application in clinical teaching practice. Methods: The vascular model, which had quite similar diameter and length to that of human arteries, was prepared with glass tubes of different diameters. Stainless steel tubes were cut and welded to manufacture the brackets of an operation bed and a C-arm, and then the above parts together with flat were assembled into the operation bed module. Fixed camera, computer and footswitch were assembled into the image module. The above three modules were integrated into the teaching simulation system of endovascular intervention. With the help of this system, the principal endovascular intervention manipulations were imitatively exercised. Results: The vascular model had the same proportions as in normal human subjects. The operation bed module could be moved in two dimensions. The image module could capture multiple and differently formatted images as well as dynamic images in different sizes. Also, this system carried the image-frozen function, which was just the same as last image hold function of DSA. This simulation system could imitate the basic manipulations of many kinds of endovascular interventions, such as the hepatic artery catheterization, carotid artery catheterization, the performing of looping-technique in uterine artery, etc. Conclusion: The simulation system can imitate many principal endovascular manipulations, and can distinctly display the relationship of the vascular anatomy and interventional instruments with their imaging shadows. Therefore, this simulation system has a promising prospect of being able to be used in the clinical teaching program concerning vascular interventional manipulations. (authors)

  10. Endovascular and surgical treatment of spinal dural arteriovenous fistulas

    International Nuclear Information System (INIS)

    Andres, Robert H.; University of Berne; Stanford University Medical Center, Department of Neurosurgery, Stanford, CA; University of Berne; Barth, Alain; Medical University of Graz, Department of Neurosurgery, Graz; University of Berne; Guzman, Raphael; Stanford University Medical Center, Department of Neurosurgery, Stanford, CA; University of Berne; Remonda, Luca; El-Koussy, Marwan; Schroth, Gerhard; University of Berne; Seiler, Rolf W.; Widmer, Hans R.; University of Berne

    2008-01-01

    The aim of this retrospective study was to evaluate the clinical outcome of patients with spinal dural arteriovenous fistulas (SDAVFs) that were treated with surgery, catheter embolization, or surgery after incomplete embolization. The study included 21 consecutive patients with SDAVFs of the thoracic, lumbar, or sacral spine who were treated in our institution from 1994 to 2007. Thirteen patients were treated with catheter embolization alone. Four patients underwent hemilaminectomy and intradural interruption of the fistula. Four patients were treated by endovascular techniques followed by surgery. The clinical outcome was assessed using the modified Aminoff-Logue scale (ALS) for myelopathy and the modified Rankin scale (MRS) for general quality of life. Patient age ranged from 44 to 77 years (mean 64.7 years). Surgical as well as endovascular treatment resulted in a significant improvement in ALS (-62.5% and -31.4%, respectively, p<0.05) and a tendency toward improved MRS (-50% and -32%, respectively) scores. Patients that underwent surgery after endovascular treatment due to incomplete occlusion of the fistula showed only a tendency for improvement in the ALS score (-16.7%), whereas the MRS score was not affected. We conclude that both endovascular and surgical treatment of SDAVFs resulted in a good and lasting clinical outcome in the majority of cases. In specific situations, when a secondary neurosurgical approach was required after endovascular treatment to achieve complete occlusion of the SDAVF, the clinical outcome was rather poor. The best first line treatment modality for each individual patient should be determined by an interdisciplinary team. (orig.)

  11. Contemporary management of carotid blowout syndrome utilizing endovascular techniques.

    Science.gov (United States)

    Manzoor, Nauman F; Rezaee, Rod P; Ray, Abhishek; Wick, Cameron C; Blackham, Kristine; Stepnick, David; Lavertu, Pierre; Zender, Chad A

    2017-02-01

    To illustrate complex interdisciplinary decision making and the utility of modern endovascular techniques in the management of patients with carotid blowout syndrome (CBS). Retrospective chart review. Patients treated with endovascular strategies and/or surgical modalities were included. Control of hemorrhage, neurological, and survival outcomes were studied. Between 2004 and 2014, 33 patients had 38 hemorrhagic events related to head and neck cancer that were managed with endovascular means. Of these, 23 were localized to the external carotid artery (ECA) branches and five localized to the ECA main trunk; nine were related to the common carotid artery (CCA) or internal carotid artery (ICA), and one event was related to the innominate artery. Seven events related to the CCA/ICA or innominate artery were managed with endovascular sacrifice, whereas three cases were managed with a flow-preserving approach (covered stent). Only one patient developed permanent hemiparesis. In two of the three cases where the flow-preserving approach was used, the covered stent eventually became exposed via the overlying soft tissue defect, and definitive management using carotid revascularization or resection was employed to prevent further hemorrhage. In cases of soft tissue necrosis, vascularized tissues were used to cover the great vessels as applicable. The use of modern endovascular approaches for management of acute CBS yields optimal results and should be employed in a coordinated manner by the head and neck surgeon and the neurointerventionalist. 4. Laryngoscope, 2016 127:383-390, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  12. Systolic Sac Pressure Index for the Prediction of Persistent Type II Endoleak for 12 Months After Endovascular Abdominal Aortic Aneurysm Repair

    Energy Technology Data Exchange (ETDEWEB)

    Ikoma, Akira, E-mail: yfb04322@nifty.com; Nakai, Motoki, E-mail: momonga@wakayama-med.ac.jp; Sato, Morio, E-mail: morisato@wakayama-med.ac.jp; Sato, Hirotatsu, E-mail: kuppa1220@yahoo.co.jp; Minamiguchi, Hiroki, E-mail: hiromina4@hotmail.com; Sonomura, Tetsuo, E-mail: sonomura@wakayama-med.ac.jp [Wakayama Medical University, Departments of Radiology (Japan); Nishimura, Yoshiharu, E-mail: nishim-y@wakayama-med.ac.jp; Okamura, Yoshitaka, E-mail: y-ok@wakayama-med.ac.jp [Wakayama Medical University, Thoracic and Cardiovascular Surgery (Japan)

    2016-04-15

    PurposeTo assess the relationship between the systolic sac pressure index (SPI) and the presence of endoleaks 12 months after endovascular abdominal aortic aneurysm repair (EVAR).Materials and MethodsWe performed a single-center prospective trial of consecutively treated patients. SPI (calculated as systolic sac pressure/systolic aortic pressure) was measured by catheterization immediately after EVAR. Contrast-enhanced computed tomography was scheduled 12 months after EVAR to detect possible endoleaks.ResultsData were available for 34 patients who underwent EVAR for an AAA. Persisting type II endoleak was found in 8 patients (endoleak-positive group) but not in the other 26 patients (endoleak-negative group). The mean ± standard deviation SPI was significantly greater in the endoleak-positive group than in the endoleak-negative group (0.692 ± 0.048 vs. 0.505 ± 0.081, respectively; P = .001). Receiver-operating characteristic curve analysis revealed that an SPI of 0.638 was the optimum cutoff value for predicting a persistent endoleak at 12 months with high accuracy (0.971; 33/34), sensitivity (1.00), and specificity (0.962) values. The mean change in AAA diameter was −4.28 ± 5.03 mm and 2.22 ± 4.54 mm in patients with SPI of <0.638 or ≥0.638, respectively (P = .002).ConclusionPatients with an SPI of ≥0.638 immediately after EVAR were more likely to have a persistent type II endoleak at 12 months with an accuracy of 0.971, and showed increases in aneurysm sac diameter compared with patients with an SPI of <0.638.

  13. Percutaneous Stent-Graft Repair of a Mycotic Pulmonary Artery Pseudoaneurysm

    International Nuclear Information System (INIS)

    Chou Meichun; Liang Hueilung; Pan Huayban; Yang Chienfang

    2006-01-01

    Ruptured mycotic pulmonary pseudoaneurysm is a lethal complication. Emergent surgical repair is usually recommended, but still associated with a high mortality rate. We present a patient in whom mycotic pulmonary pseudoaneurysm was a complication after surgical lobectomy 2 weeks earlier. This patient had suffered from repeated massive hemoptysis. After emergent surgical repair of the ruptured pulmonary artery stump, another episode of massive hemorrhage occurred. The pulmonary arteriogram revealed a segmental stenosis and a large, wide-necked, lobulated pseudoaneurysm at the left proximal pulmonary artery. We deployed a balloon-expandable stent-graft (48 mm in length mounted on a 12 mm x 40 mm angioplasty balloon) across the stenotic segment and the neck of the pulmonary pseudoaneurysm. Hemostasis was achieved immediately and, under a 4-week antibiotic treatment, patient was transferred to a local hospital for medical care. This case report demonstrates the benefit of minimally invasive endovascular therapy in a critically ill patient. A literature review of the etiology and management of mycotic pulmonary pseudoaneurysm is included

  14. Crouzon’s Syndrome with Life-Threatening Ear Bleed: Ruptured Jugular Vein Diverticulum Treated by Endovascular Embolization

    International Nuclear Information System (INIS)

    Mondel, Prabath Kumar; Anand, Sunanda; Limaye, Uday S.

    2015-01-01

    Crouzon’s syndrome is the commonest variety of syndromic craniosynostosis. Life-threatening ear bleed due to ruptured jugular venous diverticulum in Crouzon’s syndrome has not been described previously. In patients with syndromic craniosynostosis, definitive repair of jugular diverticulum by open surgery is fraught with high risk of bleeding, poor functional outcomes, and even death. A 24-year-old woman with Crouzon’s syndrome presented with conductive hearing loss and recurrent episodes of torrential bleeding from her left ear. On computed tomography, a defect in the roof of jugular fossa containing jugular venous diverticulum immediately inferior to the bony external auditory canal was seen. The clinical presentation, imaging features, and endovascular management of Crouzon’s syndrome due to a ruptured jugular venous diverticulum is described

  15. Crouzon’s Syndrome with Life-Threatening Ear Bleed: Ruptured Jugular Vein Diverticulum Treated by Endovascular Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Mondel, Prabath Kumar, E-mail: prabathmondel@gmail.com; Anand, Sunanda, E-mail: sunandaanand@gmail.com; Limaye, Uday S., E-mail: uslkem@gmail.com [Lilavati Hospital and Research Centre, Department of Interventional Neuroradiology (India)

    2015-08-15

    Crouzon’s syndrome is the commonest variety of syndromic craniosynostosis. Life-threatening ear bleed due to ruptured jugular venous diverticulum in Crouzon’s syndrome has not been described previously. In patients with syndromic craniosynostosis, definitive repair of jugular diverticulum by open surgery is fraught with high risk of bleeding, poor functional outcomes, and even death. A 24-year-old woman with Crouzon’s syndrome presented with conductive hearing loss and recurrent episodes of torrential bleeding from her left ear. On computed tomography, a defect in the roof of jugular fossa containing jugular venous diverticulum immediately inferior to the bony external auditory canal was seen. The clinical presentation, imaging features, and endovascular management of Crouzon’s syndrome due to a ruptured jugular venous diverticulum is described.

  16. Transarterial endovascular treatment in the management of life-threatening carotid blowout syndrome in head and neck cancer patients: review of the literature.

    Science.gov (United States)

    Dequanter, D; Shahla, M; Paulus, P; Aubert, C; Lothaire, P

    2013-12-01

    Carotid blowout syndrome is a rare but devastating complication in patients with head and neck malignancy, and is associated with high morbidity and mortality. Bleeding from the carotid artery or its branches is a well-recognized complication following treatment or recurrence of head and neck cancer. It is an emergency situation, and the classical approach to save the patient's life is to ligate the carotid artery. But the surgical treatment is often technically difficult. Endovascular therapies were recently reported as good alternatives to surgical ligation. Retrospective review of three cases of acute or threatened carotid hemorrhage managed by endovascular therapies. Two patients presented with acute carotid blowout, and one patient with a sentinel bleed. Two patients had previously been treated with surgery and chemo radiation. One patient was treated by chemo radiation. Two had developed pharyngocutaneous fistulas, and one had an open necrosis filled wound that surrounded the carotid artery. In two patients, stent placement resolved the acute hemorrhage. In one patient, superselective embolization was done. Mean duration follow-up was 10.2 months. No patient had residual sequelae of stenting or embolization. Management of carotid blow syndrome is very critical and difficult. A multidisciplinary approach is very important in the management of carotid blow syndrome. Correct and suitable management can be life saving. An endovascular technique is a good and effective alternative with much lower morbidity rates than surgical repair or ligation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  17. Perioperative nursing for patients with diabetic foot receiving endovascular interventional therapy

    International Nuclear Information System (INIS)

    Yang Yang; Wang Feng; Li Ke; Li Cheng; Ji Donghua

    2010-01-01

    Objective: To study the effect of perioperative nursing on the living quality of patients with diabetic foot who are treated with endovascular interventional therapy. Methods: Specific perioperative nursing care plan was accordingly designed for 43 patients with diabetic foot. Endovascular balloon angioplasty and stent implantation were formed in these patients to treat their diabetic foot. The clinical results were observed. Results: Perioperative nursing effectively improved patient's limb blood supply, enhanced the healing of diabetic foot ulceration and increased the possibility of limb preservation. Conclusion: Endovascular therapy combined with corresponding perioperative nursing care can benefit more patients with diabetic foot. (authors)

  18. Endovascular management of inferior vena cava filter thrombotic occlusion.

    Science.gov (United States)

    Branco, Bernardino C; Montero-Baker, Miguel F; Espinoza, Eduardo; Gamero, Maria; Zea-Vera, Rodrigo; Labropoulos, Nicos; Leon, Luis R

    2018-01-01

    Objective Inferior vena cava occlusion is a potentially life-threatening complication related to caval filters. We present our experience with filter-induced inferior vena cava occlusion in order to assess the feasibility, safety, and effectiveness of endovascular management. Methods A retrospective review of all patients undergoing inferior vena cava filter placement over a 60-month study period was performed. From this cohort, a total of 10 cases of inferior vena cava occlusion after filter placement were identified. Demographics, clinical data, procedures, and outcomes were extracted. Patients were followed to the last clinic visit or until they died. Results One-hundred eighty filters were placed by our group practice during the study period. Of those, a total of 10 patients were identified. Overall, there were 7 males; the mean age was 57.1 years (25-78 years). The median time between inferior vena cava filter placement and filter occlusion was 105 days (range 5-4745 days). All patients were clinically symptomatic at the time of their presentation. Nine out of 10 patients were successfully managed endovascularly. Trellis™-8 thrombectomy was the most common endovascular strategy performed ( n = 9). Four patients had balloon angioplasty, two of those with stent placement for chronically occluded inferior vena cava/iliac veins. No thromboembolic complications developed during a median follow-up period of 233 days (range 4-1083 days). Conclusions Endovascular management of inferior vena cava occlusion is feasible, safe, and effective in decreasing thrombus burden in the presence of an inferior vena cava filter. Further studies evaluating long-term inferior vena cava patency and optimal surveillance regimen after endovascular management of filter-related inferior vena cava occlusion are warranted.

  19. A Novel Technique for Endovascular Removal of Large Volume Right Atrial Tumor Thrombus

    Energy Technology Data Exchange (ETDEWEB)

    Nickel, Barbara, E-mail: nickel.ba@gmail.com [US Teleradiology and Quantum Medical Radiology Group (United States); McClure, Timothy, E-mail: tmcclure@gmail.com; Moriarty, John, E-mail: jmoriarty@mednet.ucla.edu [UCLA Medical Center, Department of Interventional Radiology (United States)

    2015-08-15

    Venous thromboembolic disease is a significant cause of morbidity and mortality, particularly in the setting of large volume pulmonary embolism. Thrombolytic therapy has been shown to be a successful treatment modality; however, its use somewhat limited due to the risk of hemorrhage and potential for distal embolization in the setting of large mobile thrombi. In patients where either thrombolysis is contraindicated or unsuccessful, and conventional therapies prove inadequate, surgical thrombectomy may be considered. We present a case of percutaneous endovascular extraction of a large mobile mass extending from the inferior vena cava into the right atrium using the Angiovac device, a venovenous bypass system designed for high-volume aspiration of undesired endovascular material. Standard endovascular methods for removal of cancer-associated thrombus, such as catheter-directed lysis, maceration, and exclusion, may prove inadequate in the setting of underlying tumor thrombus. Where conventional endovascular methods either fail or are unsuitable, endovascular thrombectomy with the Angiovac device may be a useful and safe minimally invasive alternative to open resection.

  20. A Novel Technique for Endovascular Removal of Large Volume Right Atrial Tumor Thrombus

    International Nuclear Information System (INIS)

    Nickel, Barbara; McClure, Timothy; Moriarty, John

    2015-01-01

    Venous thromboembolic disease is a significant cause of morbidity and mortality, particularly in the setting of large volume pulmonary embolism. Thrombolytic therapy has been shown to be a successful treatment modality; however, its use somewhat limited due to the risk of hemorrhage and potential for distal embolization in the setting of large mobile thrombi. In patients where either thrombolysis is contraindicated or unsuccessful, and conventional therapies prove inadequate, surgical thrombectomy may be considered. We present a case of percutaneous endovascular extraction of a large mobile mass extending from the inferior vena cava into the right atrium using the Angiovac device, a venovenous bypass system designed for high-volume aspiration of undesired endovascular material. Standard endovascular methods for removal of cancer-associated thrombus, such as catheter-directed lysis, maceration, and exclusion, may prove inadequate in the setting of underlying tumor thrombus. Where conventional endovascular methods either fail or are unsuitable, endovascular thrombectomy with the Angiovac device may be a useful and safe minimally invasive alternative to open resection

  1. Endovascular Treatment of Traumatic Pseudoaneurysm Presenting as Intractable Epistaxis

    International Nuclear Information System (INIS)

    Zhang, Chang wei; Xie, Xiao dong; You, Chao; Mao, Bo yong; Wang, Chao hua; He, Min; Sun, Hong

    2010-01-01

    To investigate the clinical efficacy of individual endovascular management for the treatment of different traumatic pseudo aneurysms presenting as intractable epistaxis. For 14 consecutive patients with traumatic pseudo aneurysm presenting as refractory epistaxis, 15 endovascular procedures were performed. Digital subtraction angiography revealed that the pseudo aneurysms originated from the internal maxillary artery in eight patients; and all were treated with occlusion of the feeding artery. In six cases, they originated from the internal carotid artery (Inca); out of which, two were managed with detachable balloons, two with covered s tents, one by means of cavity embolization, and the remaining one with parent artery occlusion. All of these cases were followed up clinically from six to 18 months, with a mean follow up time of ten months; moreover, three cases were also followed with angiography. Complete cessation of bleeding was achieved in all the 15 instances (100%) immediately after the endovascular therapies. Of the six patients who suffered from Inca pseudo aneurysms, one presented with a permanent stroke and one had an episode of rebleeding requiring intervention. In patients presenting with a history of cranio cerebral trauma, traumatic pseudo aneurysm must be considered as a differential diagnosis. Individual endovascular treatment is a relatively safe, plausible, and reliable means of managing traumatic pseudo aneurysms

  2. Endovascular treatment of ruptured true posterior communicating artery aneurysms.

    Science.gov (United States)

    Yang, Yonglin; Su, Wandong; Meng, Qinghai

    2015-01-01

    Although true posterior communicating artery (PCoA) aneurysms are rare, they are of vital importance. We reviewed 9 patients with this fatal disease, who were treated with endovascular embolization, and discussed the meaning of endovascular embolization for the treatment of true PCoA aneurysms. From September 2006 to May 2012, 9 patients with digital substraction angiography (DSA) confirmed true PCoA aneurysms were treated with endovascular embolization. Patients were followed-up with a minimal duration of 17 months and assessed by Glasgow Outcome Scale (GOS) score. All the patients presented with spontaneous subarachnoid hemorrhage from the ruptured aneurysms. The ratio of males to females was 1:2, and the average age of onset was 59.9 (ranging from 52 to 72) years. The preoperative Hunt-Hess grade scores were I to III. All patients had recovered satisfactorily. No permanent neurological deficits were left. Currently, endovascular embolization can be recommended as the top choice for the treatment of most true PCoA aneurysms, due to its advanced technique, especially the application of the stent-assisted coiling technique, combined with its advantage of mininal invasiveness and quick recovery. However, the choice of treatment methods should be based on the clinical and anatomical characteristics of the aneurysm and the skillfulness of the surgeon.

  3. Endovascular Treatment of Traumatic Pseudoaneurysm Presenting as Intractable Epistaxis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chang wei; Xie, Xiao dong; You, Chao; Mao, Bo yong; Wang, Chao hua; He, Min; Sun, Hong [Sichuan University West China Hospital, Chengdu (China)

    2010-12-15

    To investigate the clinical efficacy of individual endovascular management for the treatment of different traumatic pseudo aneurysms presenting as intractable epistaxis. For 14 consecutive patients with traumatic pseudo aneurysm presenting as refractory epistaxis, 15 endovascular procedures were performed. Digital subtraction angiography revealed that the pseudo aneurysms originated from the internal maxillary artery in eight patients; and all were treated with occlusion of the feeding artery. In six cases, they originated from the internal carotid artery (Inca); out of which, two were managed with detachable balloons, two with covered s tents, one by means of cavity embolization, and the remaining one with parent artery occlusion. All of these cases were followed up clinically from six to 18 months, with a mean follow up time of ten months; moreover, three cases were also followed with angiography. Complete cessation of bleeding was achieved in all the 15 instances (100%) immediately after the endovascular therapies. Of the six patients who suffered from Inca pseudo aneurysms, one presented with a permanent stroke and one had an episode of rebleeding requiring intervention. In patients presenting with a history of cranio cerebral trauma, traumatic pseudo aneurysm must be considered as a differential diagnosis. Individual endovascular treatment is a relatively safe, plausible, and reliable means of managing traumatic pseudo aneurysms

  4. Endovascular Treatment of Traumatic Pseudoaneurysm Presenting as Intractable Epistaxis

    Science.gov (United States)

    Zhang, Chang wei; You, Chao; Mao, Bo yong; Wang, Chao hua; He, Min; Sun, Hong

    2010-01-01

    Objective To investigate the clinical efficacy of individual endovascular management for the treatment of different traumatic pseudoaneurysms presenting as intractable epistaxis. Materials and Methods For 14 consecutive patients with traumatic pseudoaneurysm presenting as refractory epistaxes, 15 endovascular procedures were performed. Digital subtraction angiography revealed that the pseudoaneurysms originated from the internal maxillary artery in eight patients; and all were treated with occlusion of the feeding artery. In six cases, they originated from the internal carotid artery (ICA); out of which, two were managed with detachable balloons, two with covered stents, one by means of cavity embolization, and the remaining one with parent artery occlusion. All of these cases were followed up clinically from six to 18 months, with a mean follow up time of ten months; moreover, three cases were also followed with angiography. Results Complete cessation of bleeding was achieved in all the 15 instances (100%) immediately after the endovascular therapies. Of the six patients who suffered from ICA pseudoaneurysms, one presented with a permanent stroke and one had an episode of rebleeding requiring intervention. Conclusion In patients presenting with a history of craniocerebral trauma, traumatic pseudoaneurysm must be considered as a differential diagnosis. Individual endovascular treatment is a relatively safe, plausible, and reliable means of managing traumatic pseudoaneurysms. PMID:21076585

  5. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  6. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  7. Simulating the Daylight Performance of Complex Fenestration Systems Using Bidirectional Scattering Distribution Functions within Radiance

    Energy Technology Data Exchange (ETDEWEB)

    Ward, Gregory; Mistrick, Ph.D., Richard; Lee, Eleanor; McNeil, Andrew; Jonsson, Ph.D., Jacob

    2011-01-21

    We describe two methods which rely on bidirectional scattering distribution functions (BSDFs) to model the daylighting performance of complex fenestration systems (CFS), enabling greater flexibility and accuracy in evaluating arbitrary assemblies of glazing, shading, and other optically-complex coplanar window systems. Two tools within Radiance enable a) efficient annual performance evaluations of CFS, and b) accurate renderings of CFS despite the loss of spatial resolution associated with low-resolution BSDF datasets for inhomogeneous systems. Validation, accuracy, and limitations of the methods are discussed.

  8. [Incidence and risk factors of ischemic colitis after AAA repair in our cohort of patients from 2005 through 2009].

    Science.gov (United States)

    Biros, E; Staffa, R

    2011-12-01

    Using retrospective analysis, we sought to investigate the incidence, risk factors and therapeutic outcomes of ischemic colitis in patients after surgical and endovascular repair of abdominal aortic aneurysms (AAA). The complete inpatient and outpatient medical records of all patients undergoing surgical or endovascular AAA repair in our Department from January 2005 to December 2009 were retrospectively reviewed. We selected all patients who had developed an acute or chronic form of postoperative large or small bowel ischemia. We carried out data analysis and focused on determining the incidence and risk factors of this complication and the outcomes of its treatment. Two hundred and seven AAA repairs were performed in the 2nd Department of Surgery of St. Anne's University Hospital in Brno and the Faculty of Medicine of Masaryk University in Brno during the studied period. This number includes endovascular AAA repairs (13 patients; 6.3%) as well as one robot-assisted operation, and also the whole clinical spectrum of AAA manifestations, from non-symptomatic forms to ruptured aneurysm forms. The rest of the patients underwent open operation. Bowel ischemia developed in a total of 11 patients (5.3 %), who all underwent open AAA repair. Six of these patients presented with non-ruptured AAA and the remaining 5 with ruptured AAA. In 3 patients, bowel ischemia was diagnosed with a delay of several months from the original revascularization operation in the clinical form of postischemic stricture of the large bowel (2 patients) or postischemic colitis (1 patient). 8 patients were diagnosed with acute ischemic colitis affecting an isolated segment of the small bowel in one patient, extended segments of the large bowel (descending colon + sigmoid colon + rectum) in 2 patients, and typically the descending and sigmoid colon in 5 patients. None of the three patients with late manifestation of ischemic colitis died. Of the 8 patients with acute presentation, resection of the

  9. Current status of endovascular catheter robotics.

    Science.gov (United States)

    Lumsden, Alan B; Bismuth, Jean

    2018-06-01

    In this review, we will detail the evolution of endovascular therapy as the basis for the development of catheter-based robotics. In parallel, we will outline the evolution of robotics in the surgical space and how the convergence of technology and the entrepreneurs who push this evolution have led to the development of endovascular robots. The current state-of-the-art and future directions and potential are summarized for the reader. Information in this review has been drawn primarily from our personal clinical and preclinical experience in use of catheter robotics, coupled with some ground-breaking work reported from a few other major centers who have embraced the technology's capabilities and opportunities. Several case studies demonstrating the unique capabilities of a precisely controlled catheter are presented. Most of the preclinical work was performed in the advanced imaging and navigation laboratory. In this unique facility, the interface of advanced imaging techniques and robotic guidance is being explored. Although this procedure employs a very high-tech approach to navigation inside the endovascular space, we have conveyed the kind of opportunities that this technology affords to integrate 3D imaging and 3D control. Further, we present the opportunity of semi-autonomous motion of these devices to a target. For the interventionist, enhanced precision can be achieved in a nearly radiation-free environment.

  10. Advances in endovascular treatment of critical limb ischemia.

    LENUS (Irish Health Repository)

    Yan, Bryan P

    2011-04-01

    Critical limb ischemia (CLI) represents the most severe clinical manifestation of peripheral arterial disease. In the absence of timely revascularization, CLI carries high risk of mortality and amputation. Over the past decade, endovascular revascularization has rapidly become the preferred primary treatment strategy for CLI, especially for the treatment of below-the-knee disease. Advances in percutaneous devices and techniques have expanded the spectrum of patients with CLI who are deemed candidates for revascularization. This review will focus on advances in endovascular options for the treatment of CLI, in particular for below-the-knee disease.

  11. Enhancing brain lesions after endovascular treatment of aneurysms

    DEFF Research Database (Denmark)

    Cruz, J P; Marotta, T; O'Kelly, C

    2014-01-01

    present 7 patients from 5 different institutions that developed MR imaging-enhancing brain lesions after endovascular therapy of aneurysms, detected after a median time of 63 days. The number of lesions ranged from 4-46 (median of 10.5), sized 2-20 mm, and were mostly in the same vascular territory used......Complications of endovascular therapy of aneurysms mainly include aneurysm rupture and thromboembolic events. The widespread use of MR imaging for follow-up of these patients revealed various nonvascular complications such as aseptic meningitis, hydrocephalus, and perianeurysmal brain edema. We...

  12. A transgenic model for conditional induction and rescue of portal hypertension reveals a role of VEGF-mediated regulation of sinusoidal fenestrations.

    Directory of Open Access Journals (Sweden)

    Dalit May

    Full Text Available Portal hypertension (PH is a common complication and a leading cause of death in patients with chronic liver diseases. PH is underlined by structural and functional derangement of liver sinusoid vessels and its fenestrated endothelium. Because in most clinical settings PH is accompanied by parenchymal injury, it has been difficult to determine the precise role of microvascular perturbations in causing PH. Reasoning that Vascular Endothelial Growth Factor (VEGF is required to maintain functional integrity of the hepatic microcirculation, we developed a transgenic mouse system for a liver-specific-, reversible VEGF inhibition. The system is based on conditional induction and de-induction of a VEGF decoy receptor that sequesters VEGF and preclude signaling. VEGF blockade results in sinusoidal endothelial cells (SECs fenestrations closure and in accumulation and transformation of the normally quiescent hepatic stellate cells, i.e. provoking the two processes underlying sinusoidal capillarization. Importantly, sinusoidal capillarization was sufficient to cause PH and its typical sequela, ascites, splenomegaly and venous collateralization without inflicting parenchymal damage or fibrosis. Remarkably, these dramatic phenotypes were fully reversed within few days from lifting-off VEGF blockade and resultant re-opening of SECs' fenestrations. This study not only uncovered an indispensible role for VEGF in maintaining structure and function of mature SECs, but also highlights the vasculo-centric nature of PH pathogenesis. Unprecedented ability to rescue PH and its secondary manifestations via manipulating a single vascular factor may also be harnessed for examining the potential utility of de-capillarization treatment modalities.

  13. Comparison of nerve conduction and injury degree in patients with lumbar disc herniation after microendoscopic discectomy and fenestration discectomy

    Directory of Open Access Journals (Sweden)

    Jun Li

    2017-09-01

    Full Text Available Objective: To study the difference of nerve conduction and injury degree in patients with lumbar disc herniation after microendoscopic discectomy and fenestration discectomy. Methods: Patients with single-segment lumbar disc herniation who were treated in Dazhou Central Hospital between May 2014 and February 2017 were selected as the research subjects, the history data were reviewed and the operation methods were referred to divide them into FD group and MED group who received fenestration discectomy and microendoscopic discectomy respectively. The conduction velocity of common peroneal nerve and tibial nerve were detected before operation and 4 weeks after operation; serum levels of nerve and muscle injury-related molecules as well as inflammation and stress-related molecules were detected before operation and 3 days after operation. Results: MNCV levels of common peroneal nerve and tibial nerve 4 weeks after operation as well as serum CRP, TNF-α, MDA and AOPP contents 3 d after operation of both groups of patients were significantly higher than those before operation, and the MNCV levels of common peroneal nerve and tibial nerve of MED group 4 weeks after operation were significantly higher than those of FD group while serum CRP, TNF-α, MDA and AOPP contents of MED group 3 d after operation were not significantly different from those of FD group; serum NSE, S100B, Tau, pNF-H, CPK, Myo and LDH contents of FD patients 3 d after operation were significantly higher than those before operation while serum NSE, S100B, Tau, pNF-H, CPK, Myo and LDH contents of MED group were not significantly different from those before operation. Conclusion: Microendoscopic discectomy for lumbar disc herniation can relieve the nerve and muscle injury, and is equivalent to fenestration discectomy in activating the systemic stress and inflammatory response.

  14. [Closure of wide patent ductus arteriosus using a fenestrated muscular VSD occluder device in a pediatric patient with Down syndrome and pulmonary hypertension].

    Science.gov (United States)

    Güvenç, Osman; Saygı, Murat; Demir, İbrahim Halil; Ödemiş, Ender

    2017-06-01

    Patients with wide patent ductus arteriosus and significant pulmonary hypertension not treated in time constitute a significant problem for cardiologists. For these patients, tests that could aid in decision-making for further planning include reversibility and balloon occlusion tests performed in the catheterization laboratory. Devices developed for the closure of ductus as well as different devices with off-label use may be employed in patients scheduled for transcatheter occlusion. When result of reversibility test is borderline positive, the use of fenestrated device may be applicable for selected patients. Presently described is case of a 10-year-old patient with Down syndrome who had a wide ductus and systemic pulmonary hypertension. Transcatheter closure procedure was performed with off-label use of a fenestrated muscular ventricular septal defect occluder device.

  15. Outcomes of Infrainguinal Revascularizations with Endovascular First Strategy in Critical Limb Ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Jens, Sjoerd, E-mail: s.jens@amc.uva.nl [Academic Medical Center, Department of Radiology (Netherlands); Conijn, Anne P., E-mail: a.p.conijn@amc.uva.nl; Frans, Franceline A., E-mail: f.a.frans@amc.uva.nl [Academic Medical Center, Departments of Radiology and Surgery (Netherlands); Nieuwenhuis, Marieke B. B., E-mail: m.b.nieuwenhuis@amc.uva.nl; Met, Rosemarie, E-mail: rosemariemet@hotmail.com [Academic Medical Center, Department of Radiology (Netherlands); Koelemay, Mark J. W., E-mail: m.j.koelemaij@amc.uva.nl; Legemate, Dink A., E-mail: d.a.legemate@amc.uva.nl [Academic Medical Center, Department of Surgery (Netherlands); Bipat, Shandra, E-mail: s.bipat@amc.uva.nl; Reekers, Jim A., E-mail: j.a.reekers@amc.uva.nl [Academic Medical Center, Department of Radiology (Netherlands)

    2015-06-15

    PurposeThis study was designed to study the outcome of infrainguinal revascularization in patients with critical limb ischemia (CLI) in an institution with a preference towards endovascular intervention first in patients with poor condition, unfavourable anatomy for surgery, no venous material for bypass, and old age.MethodsA prospective, observational cohort study was conducted between May 2007 and May 2010 in patients presenting with CLI. At baseline, the optimal treatment was selected, i.e., endovascular or surgical treatment. In case of uncertainty about the preferred treatment, a multidisciplinary team (MDT) was consulted. Primary endpoints were quality of life and functional status 6 and 12 months after initial intervention, assessed by the VascuQol and AMC Linear Disability Score questionnaires, respectively.ResultsIn total, 113 patients were included; 86 had an endovascular intervention and 27 had surgery. During follow-up, 41 % underwent an additional ipsilateral revascularisation procedure. For the total population, and endovascular and surgery subgroups, the VascuQol sum scores improved after 6 and 12 months (p < 0.01 for all outcomes) compared with baseline. The functional status improved (p = 0.043) after 12 months compared with baseline for the total population. Functional status of the surgery subgroup improved significantly after 6 (p = 0.031) and 12 (p = 0.044) months, but not that of the endovascular subgroup.ConclusionsOverall, the strategy of performing endovascular treatment first in patients with poor condition, unfavourable anatomy for surgery, no venous material for bypass, and old age has comparable or even slightly better results compared with the BASIL trial and other cohort studies. All vascular groups should discuss whether their treatment strategy should be directed at treating CLI patients preferably endovascular first and consider implementing an MDT to optimize patient outcomes.

  16. Stroke Neurologist's Perspective on the New Endovascular Trials.

    Science.gov (United States)

    Grotta, James C; Hacke, Werner

    2015-06-01

    Before December 2014, the only proven effective treatment for acute ischemic stroke was recombinant tissue-type plasminogen activator (r-tPA). This has now changed with the publication of the Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands (MR CLEAN), Endovascular Treatment for Small Core and Anterior Circulation Proximal Occlusion With Emphasis on Minimizing CT to Recanalization Times (ESCAPE), Extending the Time for Thrombolysis in Emergency Neurological Deficits--Intra-Arterial (EXTEND IA), Solitaire With the Intention for Thrombectomy as Primary Endovascular Treatment Trial (SWIFT PRIME), and Randomized Trial of Revascularization With the Solitaire FR Device Versus Best Medical Therapy in the Treatment of Acute Stroke Due to Anterior Circulation Large Vessel Occlusion Presenting Within Eight Hours of Symptom Onset (REVASCAT) studies. We review the main results of these studies and how they inform stroke patient management going forward. The main take home points for neurologists are (1) intra-arterial thrombectomy is a potently effective treatment and should be offered to patients who have documented occlusion in the distal internal carotid or the proximal middle cerebral artery, have a relatively normal noncontrast head computed tomographic scan, severe neurological deficit, and can have intra-arterial thrombectomy within 6 hours of last seen normal; (2) benefits are clear in patients receiving r-tPA before intra-arterial thrombectomy; r-tPA should not be withheld if the patient meets criteria, and benefit in patients who do not receive r-tPA or have r-tPA exclusions requires further study; and (3) these favorable results occur when intra-arterial thrombectomy is performed in an endovascular stroke center by a coordinated multidisciplinary team that extends from the prehospital stage to the endovascular suite, minimizes time to recanalization, uses stent-retriever devices, and avoids general

  17. Disección de aorta: Aspectos básicos y manejo endovascular Aortic dissection: Basic aspects and endovascular management

    Directory of Open Access Journals (Sweden)

    Nicolás I Jaramillo

    2005-08-01

    , probablemente llegue a ser la terapia preferida, aunque la técnica todavía está en proceso de refinamiento. A nivel mundial la experiencia viene en crecimiento y hoy se entienden mejor las indicaciones y las limitaciones de esta terapia innovadora. En este artículo se hace una revisión general sobre el diagnóstico clínico y el manejo de la disección aórtica y sus variantes: el hematoma intramural y la úlcera aórtica aterosclerótica.Treatment of thoracic aortic pathology is complicated by the morbidity associated to the surgical procedure and to the frailty of an elderly and difficult population. Surgical operation in this kind of population frequently bears a significant incidence of death and long term disability. In an effort to reduce the incidence of negative outcomes, minimally invasive techniques in the form of endovascular stenting have been introduced during the past decade. The technology, originally described by Parodi, and initially designed for its use in abdominal aortic aneurysms, has been adapted for the treatment of thoracic aortic aneurysms. Furthermore, an improved understanding of the pathophysiology and the natural history of thoracic aortic disease as well as the analysis of the outcomes has facilitated our treatment decisions in terms of the timing for an appropriate intervention. Treatment of thoracic aortic dissection using endovascular stent is one of the more recent advances in this condition and is receiving increasing attention as it is a less invasive alternative to an open surgical repair. Although this technology is still innovative, significant improvements have been made lately in the design and deployment of the endovascular stent-grafts. These prostheses have been increasingly used to treat aneurysms, dissections and traumatic ruptures, as well as giant penetrating ulcers and intramural hematomas of the descending thoracic aorta with good early and mid-term outcomes. The rareness, complexity and severity of the pathology and the

  18. Actual review of diagnostics and endovascular therapy of intracranial arterial stenoses

    International Nuclear Information System (INIS)

    Gizewski, E.R.; Weber, R.; Forsting, M.

    2011-01-01

    Approximately 6 - 50 % of all ischemic strokes are caused by intracranial arterial stenosis (IAS). Despite medical prevention, patients with symptomatic IAS have a high annual risk for recurrent ischemic stroke of about 12 %, and up to 19 % in the case of high-grade IAS (≥ 70 %). Digital subtraction angiography remains the gold standard for the diagnosis and grading of IAS. However, noninvasive imaging techniques including CT angiography, MR angiography, or transcranial Doppler and duplex ultrasound examinations are used in the clinical routine to provide additional information about the brain structure and hemodynamic. However, for technical reasons, the grading of stenoses is sometimes difficult and inaccurate. To date, aspirin is recommended as the treatment of choice in the prevention of recurrent ischemic stroke in patients with IAS. IAS patients who suffer a recurrent ischemic stroke or transient ischemic attack while taking aspirin can be treated with endovascular stenting or angioplasty in specialized centers. The periprocedural complication rate of these endovascular techniques is about 2 - 7 % at experienced neuro-interventional centers. The rate of re-stenosis is reported between 10 and 40 % depending on patient age and stenosis location. Further randomized studies comparing medical secondary prevention and endovascular therapy are currently being performed. With regard to the improvement of endovascular methods and lower complication rates, the indication for endovascular therapy in IAS could be broadened especially for stenosis in the posterior circulation. (orig.)

  19. Endovascular treatment of nutcracker syndrome - a case report

    International Nuclear Information System (INIS)

    Rowinski, O.; Januszewicz, M.; Wojtaszek, M.; Nawrot, I.; Szmidt, J.

    2007-01-01

    The 'nutcracker' syndrome is most commonly caused by arterial compression of the left renal vein between the superior mesenteric artery and the aorta. As a consequence venous blood pressure increases within the renal pelvis, ureter and gonadal veins. This compression syndrome may be treated by endovascular stent implantation into the left renal vein. A 20 year old female patient was referred to us, suffering from pain in her left side, gross proteinuria and the suspicion of 'nutcracker' syndrome. Symptoms were present for the last 3 years. Angio MRI was performed and confirmed compression of the left renal vein between the aorta and the superior mesenteric artery. The patient was qualified for endovascular treatment. A self expandable metallic stent, diameter 16 x 40 mm was implanted into the left renal vein. Control venography confirmed good placement of the stent and a good immediate hemodynamic effect of the procedure. The patient remains symptom free in a 14 month follow up period. At present, endovascular stenting seems to be the method of choice for the treatment of the nutcracker syndrome. (author)

  20. Endovascular aortic graft infection resulting in retroperitoneal abscess: report of a case

    Directory of Open Access Journals (Sweden)

    Salvatore Di Somma

    2010-06-01

    Full Text Available Infection is a rare complication of aortoiliac endovascular procedures, with an incidence inferior to 0.5%, and it may result in a retroperitoneal abscess potentially evolving to sepsis and gastrointestinal bleeding. In more than 50% of cases endovascular aortoiliac prosthetic grafts infection occur months or years after the procedure. The growing number of endovascular procedures, and as the actually midterm follow up in most cases, septic sequelae will no doubt continue to occur with increased frequency and may represent an emerging problem in the ED for the emergency physician. Endovascular graft infection begins with unspecific clinical manifestations. An high index of suspicion in any patient with an aortic stent graft presenting prolonged or recurrent fever and or abdominal or back pain and a low threshold for obtaining CT scan should increase the clinician’s ability to make a timely diagnosis in the ED setting.

  1. Intestinal infarction: A complication of endovascular therapy

    International Nuclear Information System (INIS)

    England, Andrew; Butterfield, John S.; Sukumar, Sathi; Thompson, David; Roulson, Jo-An; Pritchard, Susan; Ashleigh, Raymond J.

    2007-01-01

    This report presents a rare case of intestinal infarction following endovascular therapy. A female patient who had undergone an internal carotid artery stenting procedure presented suddenly with abdominal pain. Radiological and clinical examinations at the time suggested a picture of intestinal ischaemia, in view of the patient's general conditions and co-existing morbidities surgical intervention was not considered to be an option. The patient died 4 days after the carotid stenting procedure, post-mortem examination revealed infarction of the ileum and caecum. The learning outcomes are if performing endovascular therapy in a patient with diffuse atherosclerotic disease early consideration of intestinal ischaemia should be given to any patient who presents with acute post-procedural abdominal pain

  2. Intestinal infarction: A complication of endovascular therapy

    Energy Technology Data Exchange (ETDEWEB)

    England, Andrew [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom)]. E-mail: andrew.england@smtr.nhs.uk; Butterfield, John S. [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Sukumar, Sathi [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Thompson, David [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Roulson, Jo-An [Department of Histopathology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Pritchard, Susan [Department of Histopathology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Ashleigh, Raymond J. [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom)

    2007-08-15

    This report presents a rare case of intestinal infarction following endovascular therapy. A female patient who had undergone an internal carotid artery stenting procedure presented suddenly with abdominal pain. Radiological and clinical examinations at the time suggested a picture of intestinal ischaemia, in view of the patient's general conditions and co-existing morbidities surgical intervention was not considered to be an option. The patient died 4 days after the carotid stenting procedure, post-mortem examination revealed infarction of the ileum and caecum. The learning outcomes are if performing endovascular therapy in a patient with diffuse atherosclerotic disease early consideration of intestinal ischaemia should be given to any patient who presents with acute post-procedural abdominal pain.

  3. Endovascular treatment of intracranial venous sinus thrombosis

    International Nuclear Information System (INIS)

    Xu Shubin; Liang Zhihui; Cui Jinguo; Tian Huiqin; Li Liang; Chen Feng

    2009-01-01

    Objective: To evaluate the clinical efficacy and safety of endovascular treatment for intracranial venous sinus thrombosis. Methods: Ten patients with intracranial venous sinus thrombosis, confirmed by CT, MRI, MRV and / or DSA and encountered during the period of Aug. 2005-Aug. 2007, were treated with endovascular management after they failed to respond to anticoagulant therapy. Of ten patients, intravenous thrombolysis and mechanical thrombus maceration were carried out in 6, while intravenous thrombolysis, mechanical thrombus maceration together with intra-arterial thrombolysis were employed in 4. After the treatment, the anticoagulant therapy continued for 6 months. The patients were followed up for 12-29 months (mean 21 months). Results: After the treatment, the clinical symptoms and signs were completely or partially relieved in eight patients, including disappearance of headache (n=6) and relive of headache (n=2). No obvious improvement was found in one patient and linguistic function disturbance was seen in the remaining one. Lumbar puncture showed that the cerebrospinal fluid pressure returned to normal in all patients. Neither recurrence of thrombosis nor new symptom of neuralgic dysfunction was observed. No procedure-related intracranial or systemic hemorrhagic complications occurred both during and after the operation. Conclusion: Endovascular treatment is an effective and safe procedure for the potentially catastrophic intracranial venous thrombosis. (authors)

  4. Complications of endovascular treatment of cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Orrù, Emanuele, E-mail: surgeon.ema@gmail.com [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Roccatagliata, Luca, E-mail: lroccatagliata@neurologia.unige.it [Neuroradiology Department, IRCCS San Martino University Hospital and IST, Largo Rosanna Benzi 10, Genoa 16132 (Italy); Department of Health Sciences (DISSAL), University of Genoa (Italy); Cester, Giacomo, E-mail: giacomo.cester@sanita.padova.it [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Causin, Francesco, E-mail: francesco.causin@sanita.padova.it [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Castellan, Lucio, E-mail: lucio.castellan@hsanmartino.it [Neuroradiology Department, IRCCS San Martino University Hospital and IST, Largo Rosanna Benzi 10, Genoa 16132 (Italy)

    2013-10-01

    The number of neuroendovascular treatments of both ruptured and unruptured aneurysms has increased substantially in the last two decades. Complications of endovascular treatments of cerebral aneurysms are rare but can potentially lead to acute worsening of the neurological status, to new neurological deficits or death. Some of the possible complications, such as vascular access site complications or systemic side effects associated with contrast medium (e.g. contrast medium allergy, contrast induced nephropathy) can also be encountered in diagnostic angiography. The most common complications of endovascular treatment of cerebral aneurysms are related to acute thromboembolic events and perforation of the aneurysm. Overall, the reported rate of thromboembolic complications ranges between 4.7% and 12.5% while the rate of intraprocedural rupture of cerebral aneurysms is about 0.7% in patients with unruptured aneurysms and about 4.1% in patients with previously ruptured aneurysms. Thromboembolic and hemorrhagic complications may occur during different phases of endovascular procedures and are related to different technical, clinical and anatomic reasons. A thorough knowledge of the different aspects of these complications can reduce the risk of their occurrence and minimize their clinical sequelae. A deep understanding of complications and of their management is thus part of the best standard of care.

  5. Endovascular stent-graft exclusion of aortic dissection combined with renal failure

    International Nuclear Information System (INIS)

    Feng Xiang; Jing Zaiping; Yuan Weijie; Bao Junmin; Zhao Zhiqing; Zhao Jun; Lu Qingsheng

    2003-01-01

    Objective: To investigate the indications and peri-operative management of endovascular graft exclusion of aortic dissection combined with renal failure. Methods: Endovascular graft exclusion for Stanford B type thoracic aortic dissection had been preformed on 136 patients including two complicated with renal failure. Hemodialysis was preformed before operation with the fluid infusion controlled during the operation and bed-side hemodialysis after the operation for the latter. Results: All the 2 cases with renal failure complication were successfully carried out, and the peri-operative metabolism and circulation were kept on smoothly. Conclusions: Under good peri-operative management, patients having aortic dissection combined with renal failure could receive the endovascular graft exclusion of aortic dissection safely

  6. Headache and endovascular procedures.

    Science.gov (United States)

    de Biase, Stefano; Longoni, Marco; Gigli, Gian Luigi; Agostoni, Elio

    2017-05-01

    The International Classification of Headache Disorders (ICHD-3 beta) includes headache attributed to intracranial endovascular procedures (EVPs). The aim of this review is to describe the clinical and pathophysiological aspects of headache related to vascular lesions and EVPs. Current studies regarding this issue are contradictory, although generally favouring headache improvement after EVPs. Further large studies are needed to adequately assess the effect of EVPs on headache.

  7. [Actual review of diagnostics and endovascular therapy of intracranial arterial stenoses].

    Science.gov (United States)

    Gizewski, E R; Weber, R; Forsting, M

    2011-02-01

    Approximately 6 - 50% of all ischemic strokes are caused by intracranial arterial stenosis (IAS). Despite medical prevention, patients with symptomatic IAS have a high annual risk for recurrent ischemic stroke of about 12%, and up to 19% in the case of high-grade IAS (≥ 70%). Digital subtraction angiography remains the gold standard for the diagnosis and grading of IAS. However, noninvasive imaging techniques including CT angiography, MR angiography, or transcranial Doppler and duplex ultrasound examinations are used in the clinical routine to provide additional information about the brain structure and hemodynamic. However, for technical reasons, the grading of stenoses is sometimes difficult and inaccurate. To date, aspirin is recommended as the treatment of choice in the prevention of recurrent ischemic stroke in patients with IAS. IAS patients who suffer a recurrent ischemic stroke or transient ischemic attack while taking aspirin can be treated with endovascular stenting or angioplasty in specialized centers. The periprocedural complication rate of these endovascular techniques is about 2 - 7% at experienced neuro-interventional centers. The rate of re-stenosis is reported between 10 and 40% depending on patient age and stenosis location. Further randomized studies comparing medical secondary prevention and endovascular therapy are currently being performed. With regard to the improvement of endovascular methods and lower complication rates, the indication for endovascular therapy in IAS could be broadened especially for stenosis in the posterior circulation. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Type 1a endoleak following Zone 1 and Zone 2 thoracic endovascular aortic repair: effect of bird-beak configuration.

    Science.gov (United States)

    Kudo, Tomoaki; Kuratani, Toru; Shimamura, Kazuo; Sakamoto, Tomohiko; Kin, Keiwa; Masada, Kenta; Shijo, Takayuki; Torikai, Kei; Maeda, Koichi; Sawa, Yoshiki

    2017-10-01

    Type 1a endoleak is one of the most severe complications after thoracic endovascular aortic repair (TEVAR), because it carries the risk of aortic rupture. The association between bird-beak configuration and Type 1a endoleak remains unclear. The purpose of this study was to analyse the predictors of Type 1a endoleak following Zone 1 and Zone 2 TEVAR, with a particular focus on the effect of bird-beak configuration. From April 2008 to July 2015, 105 patients (mean age 68.6 years) who underwent Zone 1 and 2 landing TEVAR were enrolled, with a mean follow-up period of 4.3 years. The patients were categorized into 2 groups, according to the presence (Group B, n = 32) or the absence (Group N, n = 73) of bird-beak configuration on the first postoperative multidetector computed tomography. The Kaplan-Meier event-free rate curve showed that Type 1a endoleak and bird-beak progression occurred less frequently in Group N than in Group B. Five-year freedom from Type 1a endoleak rates were 79.7% and 100% for Groups B and N, respectively (P = 0.007). Multivariable logistic regression analysis showed that dissecting aortic aneurysm (odds ratio 3.72, 95% confidence interval 1.30-11.0; P = 0.014) and shorter radius of inner curvature (odds ratio 1.09, 95% confidence interval 0.85-0.99; P = 0.025) were significant risk factors for bird-beak configuration. Multivariable Cox proportional hazard regression showed that Z-type stent graft (hazard ratio 2.69, 95% confidence interval 1.11-6.51; P = 0.030) was a significant risk factor for bird-beak progression. Appropriate stent grafts need to be chosen carefully to prevent Type 1a endoleak and bird-beak configuration after landing Zone 1 and 2 TEVAR. Patients with bird-beak configuration on early postoperative multidetector computed tomography require closer follow-up to screen for Type 1a endoleak. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio

  9. Endovascular retrieval of a CardioMEMS heart failure system

    Directory of Open Access Journals (Sweden)

    Arun Reghunathan, MD

    2018-04-01

    Full Text Available As the creation and utilization of new implantable devices increases, so does the need for interventionalists to devise unique retrieval mechanisms. This report describes the first endovascular retrieval of a CardioMEMS heart failure monitoring device. A 20-mm gooseneck snare was utilized in conjunction with a 9-French sheath and Envoy catheter for retrieval. The patient suffered no immediate postprocedural complications but died 5 days after the procedure from multiorgan failure secondary to sepsis. Keywords: CardioMEMS heart failure system, Endovascular retrieval

  10. Experiencia en el manejo endovascular para el tratamiento de la aorta torácica Experience in endovascular management for thoracic aorta treatment

    Directory of Open Access Journals (Sweden)

    Juan G Barrera

    2007-12-01

    Full Text Available Antecedentes: el tratamiento endovascular ofrece la posibilidad de cubrir el origen de la disección y evitar que progrese hasta aneurisma de la aorta, y con ello demuestra una reducción en la mortalidad hasta del 16%. Objetivo: evaluar los resultados quirúrgicos en términos de morbi-mortalidad de los pacientes sometidos a manejo endovascular de las lesiones de la aorta torácica en la Fundación Cardiovascular de Colombia desde 2003 hasta 2005. Diseño-método: estudio longitudinal tipo descriptivo retrospectivo, en el que se evaluaron las historias clínicas de todos los pacientes sometidos a manejo endovascular de patología toracoabdominal; en éste sólo se incluyeron los pacientes con procedimientos de la aorta torácica, desde 2003 hasta 2005. El análisis de los datos se realizó en Stata/SE 8,0. Resultados: se realizaron procedimientos de aorta torácica en 16 pacientes. El 75% de los pacientes eran hombres con edad promedio de 55,9 ± 12,6 años. El 87,5% (14 pacientes presentaban disección aórtica tipo A o B; un paciente transección traumática de la aorta y un paciente aneurisma de aorta torácica descendente. Las disecciones agudas se presentaron en 78,6% (11 pacientes y las crónicas en 21,4% (3 pacientes. El promedio de endoprótesis usadas fue de 2,8 ± 1. La estancia en la unidad de cuidados intensivos fue de 3 ± 2,7 días. El 81,3% de los pacientes no presentaron complicaciones mayores. La mortalidad fue del 18,7% (3 pacientes. A todos se les realizó control post-operatorio con tomografía axial computarizada, con evolución satisfactoria. Conclusión: de acuerdo con los reportes de la literatura con mayor casuística, se considera que el manejo endovascular para el tratamiento de la disección, aneurisma o trauma aórtico es un procedimiento confiable que disminuye la morbi-mortalidad.Antecedents: endovascular treatment has the possibility of covering the dissection origin and to avoid its progression to aortic

  11. Fatal late multiple emboli after endovascular treatment of abdominal aortic aneurysm. Case report

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Sandermann, Jes; Bruun-Petersen, J

    1998-01-01

    The short term experience of endovascular treatment of abdominal aortic aneurysms (AAA) seems promising but long term randomised data are lacking. Consequently, cases treated by endovascular procedures need to be closely followed for potential risks and benefits....

  12. Patient and Aneurysm Characteristics Predicting Prolonged Length of Stay After Elective Open AAA Repair in the Endovascular Era.

    Science.gov (United States)

    Casillas-Berumen, Sergio; Rojas-Miguez, Florencia A; Farber, Alik; Komshian, Sevan; Kalish, Jeffrey A; Rybin, Denis; Doros, Gheorghe; Siracuse, Jeffrey J

    2018-01-01

    Open aortic aneurysm repair (AAA) repair can be resource intensive and associated with a prolonged length of stay (LOS). We sought to examine patient and aneurysm predictors of prolonged LOS to better identify those at risk in the preoperative setting. Patient data were obtained from the targeted AAA American College of Surgery National Surgical Quality Improvement Program database from 2012 to 2014 of patients undergoing open AAA repair. Multivariable logistic regression was used to determine predictors of prolonged postoperative LOS defined as greater than 10 days (75th percentile). There were 1172 open AAA repairs identified. The majority (54%) of patients were older than 70 years and male (74%). Surgical approach was transperitoneal (70.9%) and retroperitoneal (29.1%). Aneurysms were 51.4% infrarenal, 33% juxtarenal, 5.7% pararenal, 7.4% suprarenal, and 2.5% type IV thoracoabdominal. Mean and median LOS were 9.1 ± 7.4 and 7 (0-72) days, respectively. Independently associated with extended LOS factors were visceral revascularization (odds ratio [OR]: 5.32, 95% confidence interval [CI]: 2.77-10.22, P AAA repair. Prospective identification of high-risk patients may allow physicians and hospitals to engage in multidisciplinary collaborations preoperatively to try to improve LOS in this resource-intensive population.

  13. Transatlantic Multispecialty Consensus on Fundamental Endovascular Skills: Results of a Delphi Consensus Study.

    Science.gov (United States)

    Maertens, H; Aggarwal, R; Macdonald, S; Vermassen, F; Van Herzeele, I

    2016-01-01

    The aim of this study was to establish a consensus on Fundamental Endovascular Skills (FES) for educational purposes and development of training curricula for endovascular procedures. The term "Fundamental Endovascular Skills" is widely used; however, the current literature does not explicitly describe what skills are included in this concept. Endovascular interventions are performed by several specialties that may have opposing perspectives on these skills. A two round Delphi questionnaire approach was used. Experts from interventional cardiology, interventional radiology, and vascular surgery from the United States and Europe were invited to participate. An electronic questionnaire was generated by endovascular therapists with an appropriate educational background but who would not participate in subsequent rounds. The questionnaire consisted of 50 statements describing knowledge, technical, and behavioral skills during endovascular procedures. Experts received the questionnaires by email. They were asked to rate the importance of each skill on a Likert scale from 1 to 5. A statement was considered fundamental when more than 90% of the experts rated it 4 or 5 out of 5. Twenty-three of 53 experts invited agreed to participate: six interventional radiologists (2 USA, 4 Europe), 10 vascular surgeons (4 USA, 6 Europe), and seven interventional cardiologists (4 USA, 3 Europe). There was a 100% response rate in the first round and 87% in the second round. Results showed excellent consensus among responders (Cronbach's alpha = .95 first round; .93 second round). Ninety percent of all proposed skills were considered fundamental. The most critical skills were determined. A transatlantic multispecialty consensus was achieved about the content of "FES" among interventional radiologists, interventional cardiologists, and vascular surgeons from Europe and the United States. These results can serve as directive principles for developing endovascular training curricula

  14. Endovascular Mechanical Thrombectomy in Basilar Artery Occlusion: Initial Experience

    Science.gov (United States)

    Park, Bum-Soo; Kwon, Hyon-Jo; Choi, Seung-Won; Kim, Seon-Hwan; Koh, Hyeon-Song; Youm, Jin-Young; Song, Shi-Hun

    2013-01-01

    Objective This study was conducted to assess the efficacy and safety of endovascular mechanical thrombectomy (EMT) for patients diagnosed with basilar artery (BA) occlusion. Materials and Methods We retrospectively analyzed clinical and imaging data of 16 patients diagnosed with BA occlusion who were treated with endovascular intervention from July 2012 to February 2013. Direct suction using the Penumbra system and thrombus retrieval by the Solitaire stent were the main endovascular techniques used to restore BA flow. The outcomes were evaluated based on rate of angiographic recanalization, rate of improvement of National Institutes of Health Stroke Scale (NIHSS) score, rate of modified Rankin Scale (mRS) at discharge and after 3 months, and rate of cerebral hemorrhagic complications. Successful recanalization was defined as achieving Thrombolysis In Cerebral Infarction (TICI) of II or III. Results Sixteen patients received thrombectomy. The mean age was 67.8 ± 11 years and the mean NIHSS score was 12.3 ± 8.2. Eight patients treated within 6 hours of symptom onset were grouped as A and the other 8 patients treated beyond 6 hours (range, 6-120) were grouped as B. Successful recanalization was met in six patients (75%) for group A and 7 (87.5%) for group B. Favorable outcome occurred in 4 patients (50%) for group A and 5 (62.5%) for group B. Conclusion Our study supports the effectiveness and safety of endovascular mechanical thrombectomy in treating BA occlusion even 6 hours after symptom onset. PMID:24167791

  15. Physical aspects of endovascular brachytherapy

    International Nuclear Information System (INIS)

    Kirisits, C.

    2001-11-01

    Restenosis is severely limiting the outcome of vascular interventions. In several clinical trials endovascular brachytherapy has shown to reduce the restenosis rate. Local radiotherapy to the injured vessel wall is a promising new type of treatment in order to inhibit a complex wound healing process resulting in cell proliferation and re-obstruction of the treated vessel. Treatment planning has to be based on the dose distribution in the vicinity of the sources used. Source strength was determined in terms of air kerma rate for gamma nuclides (Iridium-192) and absorbed dose to water at reference distance of 2 mm for beta nuclides (Strontium-90/Yttrium-90, Phosphor-32), respectively. Radial dose profiles and the Reference Isodose Length (RIL) were determined using the EGSnrc code and GafChromic film. Good agreement was found between both methods. In order to treat the entire clinical target length, the (RIL) is an essential value during treatment planning. Examples are described for different levels of treatment planing including recommendations for optimal choice and positioning of the radioactive devices inside the artery. IVUS based treatment planning is illustrated with superposition of isodoses on cross-sectional images. A calculation model for radioactive stents is presented in order to determine dose volume histograms in a retrospective analysis. Radiation protection issues for endovascular brachytherapy are discussed in detail. Personal dose for the involved personnel is estimated based on calculations and measurements. Beta ray dosimetry is performed with suitable detectors. In order to estimate the exposure to the patient the dose to organs at risk is calculated and compared to the dose from angiography. There is an additional radiation exposure to patients and personnel caused by endovascular brachytherapy, but the values are much smaller than those caused by diagnostic angiography. (author)

  16. The VIRTUE Registry of type B thoracic dissections--study design and early results

    DEFF Research Database (Denmark)

    2011-01-01

    Endovascular procedures for repair of Type B aortic dissection have become increasingly common and are often considered to be first line therapy for acute complicated dissections. The long term durability of these repairs is largely undefined.......Endovascular procedures for repair of Type B aortic dissection have become increasingly common and are often considered to be first line therapy for acute complicated dissections. The long term durability of these repairs is largely undefined....

  17. Persistent Intraluminal Pressure After Endovascular Stent Grafting for Type B Aortic Dissection.

    Science.gov (United States)

    Qing, K-X; Chan, Y-C; Ting, A C W; Cheng, S W K

    2016-05-01

    Despite technically successful thoracic endovascular stent graft repair (TEVAR) in patients with Stanford Type B aortic dissection (TBAD), long-term follow up studies have shown that the false lumen may continue to dilate. The aim of this study was to analyze the possible mechanisms leading to such changes from a hemodynamic perspective. Twenty-eight ex vivo fresh porcine TBAD models (Mo A: 10; Model B: 12; Model C: 6) were established to simulate three clinical situations: Model A with patent false lumen (pre-TEVAR); Model B with distal re-entry only (post-TEVAR), and Model C with thrombus filling in the false lumen and a distal re-entry (chronic stage of post-TEVAR). Synchronous pressure waveforms were taken from both the true and the false lumen. True lumen and false lumen pressure differences were calculated for each model as four indices: systolic index (SI), diastolic index (DI), mean pressure index (MPI) and area under curve index (AUCI). These indices were compared between the three models. False lumen pressure and corresponding pressure-accumulating effects were significantly higher in Model A than in Model C: SI (99.9% vs. 189.4%; p area under curve (AUC) in Model C was merely lowered by 20% compared with its true lumen (67.5 mmHg vs. 85.2 mmHg). The false lumen pressure remained unchanged in the non-thrombosed segment with patent blood flow after the primary entry tear sealed. Intraluminal pressure reduction in the thrombosed false lumen was significant. However, nearly 80% of the pressure remained in the thrombosed false lumen. If this high intra-thrombus pressure persists, it may contribute to delayed aneurysmal formation after endovascular treatment. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  18. Can Early Computed Tomography Angiography after Endovascular Aortic Aneurysm Repair Predict the Need for Reintervention in Patients with Type II Endoleak?

    Energy Technology Data Exchange (ETDEWEB)

    Dudeck, O., E-mail: oliver.dudeck@med.ovgu.de [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Schnapauff, D. [Charité Universitätsmedizin Berlin, Department of Radiology (Germany); Herzog, L.; Löwenthal, D.; Bulla, K.; Bulla, B. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Halloul, Z.; Meyer, F. [University of Magdeburg, Department of General, Visceral and Vascular Surgery (Germany); Pech, M. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Gebauer, B. [Charité Universitätsmedizin Berlin, Department of Radiology (Germany); Ricke, J. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany)

    2015-02-15

    PurposeThis study was designed to identify parameters on CT angiography (CTA) of type II endoleaks following endovascular aortic aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA), which can be used to predict the subsequent need for reinterventions.MethodsWe retrospectively identified 62 patients with type II endoleak who underwent early CTA in mean 3.7 ± 1.9 days after EVAR. On the basis of follow-up examinations (mean follow-up period 911 days; range, 373–1,987 days), patients were stratified into two groups: those who did (n = 18) and those who did not (n = 44) require reintervention. CTA characteristics, such as AAA, endoleak, as well as nidus dimensions, patency of the inferior mesenteric artery, number of aortic branch vessels, and the pattern of endoleak appearance, were recorded and correlated with the clinical outcome.ResultsUnivariate and receiver operating characteristic curve regression analyses revealed significant differences between the two groups for the endoleak volume (surveillance group: 1391.6 ± 1427.9 mm{sup 3}; reintervention group: 3227.7 ± 2693.8 mm{sup 3}; cutoff value of 2,386 mm{sup 3}; p = 0.002), the endoleak diameter (13.6 ± 4.3 mm compared with 25.9 ± 9.6 mm; cutoff value of 19 mm; p < 0.0001), the number of aortic branch vessels (2.9 ± 1.2 compared with 4.2 ± 1.4 vessels; p = 0.001), as well as a “complex type” endoleak pattern (13.6 %, n = 6 compared with 44.4 %, n = 8; p = 0.02).ConclusionsEarly CTA can predict the future need for reintervention in patients with type II endoleak. Therefore, treatment decision should be based not only on aneurysm enlargement alone but also on other imaging characteristics.

  19. Predictors of outcome after elective endovascular abdominal aortic aneurysm repair and external validation of a risk prediction model.

    Science.gov (United States)

    Wisniowski, Brendan; Barnes, Mary; Jenkins, Jason; Boyne, Nicholas; Kruger, Allan; Walker, Philip J

    2011-09-01

    Endovascular abdominal aortic aneurysm (AAA) repair (EVAR) has been associated with lower operative mortality and morbidity than open surgery but comparable long-term mortality and higher delayed complication and reintervention rates. Attention has therefore been directed to identifying preoperative and operative variables that influence outcomes after EVAR. Risk-prediction models, such as the EVAR Risk Assessment (ERA) model, have also been developed to help surgeons plan EVAR procedures. The aims of this study were (1) to describe outcomes of elective EVAR at the Royal Brisbane and Women's Hospital (RBWH), (2) to identify preoperative and operative variables predictive of outcomes after EVAR, and (3) to externally validate the ERA model. All elective EVAR procedures at the RBWH before July 1, 2009, were reviewed. Descriptive analyses were performed to determine the outcomes. Univariate and multivariate analyses were performed to identify preoperative and operative variables predictive of outcomes after EVAR. Binomial logistic regression analyses were used to externally validate the ERA model. Before July 1, 2009, 197 patients (172 men), who were a mean age of 72.8 years, underwent elective EVAR at the RBWH. Operative mortality was 1.0%. Survival was 81.1% at 3 years and 63.2% at 5 years. Multivariate analysis showed predictors of survival were age (P = .0126), American Society of Anesthesiologists (ASA) score (P = .0180), and chronic obstructive pulmonary disease (P = .0348) at 3 years and age (P = .0103), ASA score (P = .0006), renal failure (P = .0048), and serum creatinine (P = .0022) at 5 years. Aortic branch vessel score was predictive of initial (30-day) type II endoleak (P = .0015). AAA tortuosity was predictive of midterm type I endoleak (P = .0251). Female sex was associated with lower rates of initial clinical success (P = .0406). The ERA model fitted RBWH data well for early death (C statistic = .906), 3-year survival (C statistic = .735), 5-year

  20. Endovascular Device Testing with Particle Image Velocimetry Enhances Undergraduate Biomedical Engineering Education

    Science.gov (United States)

    Nair, Priya; Ankeny, Casey J.; Ryan, Justin; Okcay, Murat; Frakes, David H.

    2016-01-01

    We investigated the use of a new system, HemoFlow™, which utilizes state of the art technologies such as particle image velocimetry to test endovascular devices as part of an undergraduate biomedical engineering curriculum. Students deployed an endovascular stent into an anatomical model of a cerebral aneurysm and measured intra-aneurysmal flow…

  1. de novo'' aneurysms following endovascular procedures

    International Nuclear Information System (INIS)

    Briganti, F.; Cirillo, S.; Caranci, F.; Esposito, F.; Maiuri, F.

    2002-01-01

    Two personal cases of ''de novo'' aneurysms of the anterior communicating artery (ACoA) occurring 9 and 4 years, respectively, after endovascular carotid occlusion are described. A review of the 30 reported cases (including our own two) of ''de novo'' aneurysms after occlusion of the major cerebral vessels has shown some features, including a rather long time interval after the endovascular procedure of up to 20-25 years (average 9.6 years), a preferential ACoA (36.3%) and internal carotid artery-posterior communicating artery (ICA-PCoA) (33.3%) location of the ''de novo'' aneurysms, and a 10% rate of multiple aneurysms. These data are compared with those of the group of reported spontaneous ''de novo'' aneurysms after SAH or previous aneurysm clipping. We agree that the frequency of ''de novo'' aneurysms after major-vessel occlusion (two among ten procedures in our series, or 20%) is higher than commonly reported (0 to 11%). For this reason, we suggest that patients who have been submitted to endovascular major-vessel occlusion be followed up for up to 20-25 years after the procedure, using non-invasive imaging studies such as MR angiography and high-resolution CT angiography. On the other hand, periodic digital angiography has a questionable risk-benefit ratio; it may be used when a ''de novo'' aneurysm is detected or suspected on non-invasive studies. The progressive enlargement of the ACoA after carotid occlusion, as described in our case 1, must be considered a radiological finding of risk for ''de novo'' aneurysm formation. (orig.)

  2. Virtual reality simulation for the optimization of endovascular procedures: current perspectives

    OpenAIRE

    Rudarakanchana, Nung; Van Herzeele, Isabelle; Desender, Liesbeth; Cheshire, Nicholas JW

    2015-01-01

    Nung Rudarakanchana,1 Isabelle Van Herzeele,2 Liesbeth Desender,2 Nicholas JW Cheshire1 1Department of Surgery, Imperial College London, London, UK; 2Department of Thoracic and Vascular Surgery, Ghent University Hospital, Ghent, BelgiumOn behalf of EVEREST (European Virtual reality Endovascular RESearch Team)Abstract: Endovascular technologies are rapidly evolving, often requiring coordination and cooperation between clinicians and technicians from diverse specialties. These multidisciplinary...

  3. The 100 most cited articles in the endovascular management of intracranial aneurysms.

    Science.gov (United States)

    Maingard, Julian; Phan, Kevin; Ren, Yifan; Kok, Hong Kuan; Thijs, Vincent; Hirsch, Joshua A; Lee, Michael J; Chandra, Ronil V; Brooks, Duncan Mark; Asadi, Hamed

    2018-01-19

    Endovascular interventions for intracranial aneurysms have evolved substantially over the past several decades. A citation rank list is used to measure the scientific and/or clinical impact of an article. Our objective was to identify and analyze the characteristics of the 100 most cited articles in the field of endovascular therapy for intracranial aneurysms. We performed a retrospective bibliometric analysis between July and August 2017. Articles were searched on the Science Citation Index Expanded database using Web of Science in order to identify the most cited articles in the endovascular therapy of intracranial aneurysms since 1945. Using selected key terms ('intracranial aneurysm', 'aneurysm', 'aneurysmal subarachnoid', 'endovascular', 'coiling', 'stent-assisted', 'balloon-assisted', 'flow-diversion') yielded a total of 16 314 articles. The top 100 articles were identified and analyzed to extract relevant information, including citation count, authorship, article type, subject matter, institution, country of origin, and year of publication. Citations for the top 100 articles ranged from 133 to 1832. All articles were cited an average of 27 times per year. There were 45 prospective studies, including 7 level-II randomized controlled trials. Most articles were published in the 2000s (n=53), and the majority constituted level III or level IV evidence. Half of the top 100 articles arose from the USA. This study provides a comprehensive overview of the most cited articles in the endovascular management of intracranial aneurysms. It recognizes the contributions made by key authors and institutions, providing an important framework to an enhanced understanding of the evidence behind the endovascular treatment of aneurysms. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Surgical treatment and thoracic endovascular aortic repair in type A aortic dissection in a pregnant patient with Marfan syndrome.

    Science.gov (United States)

    Sterner, Doerthe; Probst, Chris; Mellert, Friedrich; Schiller, Wolfgang

    2014-07-01

    We report an acute aortic dissection type Stanford A extending down to both iliac arteries affecting a 32-year-old woman suspected to have Marfan syndrome during week 37 of pregnancy. In a multidisciplinary approach, and emergency Cesarean section was performed followed by an abdominal hysterectomy and a valve-sparing aortic root replacement using a reimplantation technique. The aorta was replaced up to the hemi arch. Because of the high suspicion of visceral ischemia as confirmed ex juvantibus, an endovascular stent graft was implanted. Molecular testing revealed a frameshift mutation and confirmed the diagnosis of Marfan syndrome. Both the patient and her healthy child underwent an uneventful recovery. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Recovery of Third Nerve Palsy after Endovascular Packing of Internal Carotid-Posterior Communicating Artery Aneurysms

    Science.gov (United States)

    Mavilio, N.; Pisani, R.; Rivano, C.; Testa, V.; Spaziante, R.; Rosa, M.

    2000-01-01

    Summary Endovascular packing of intracranial aneurysm with preservation of the parent vessel has become in many cases a valid alternative to surgical clipping. Regression of oculomotor disorders after clipping of internal carotid-posterior communicating artery (ICA-PCoA) aneurysms has been well assessed. This report focuses on the reversal of third nerve palsy after endovascular packing of ICA-PCoA aneurysms. To this end, clinical appearances, neuroradiological features, and endovascular interventional procedures of six treated patient are reported and discussed in the light of the very few previous case observations found in the literature. Results indicate that endovascular packing of ICA-PCoA aneurysms may produce effective recovery of correlated third nerve dysfunction. PMID:20667199

  6. Endovascular treatment of very small intracranial aneurysms

    DEFF Research Database (Denmark)

    Iskandar, A; Nepper-Rasmussen, J

    2011-01-01

    to large aneurysms (> 3 mm). However the data also suggest that endovascular treatment of very small aneurysms might be associated with an increased risk of procedural ruptures and mortality. At nine-month follow-up results indicate significantly less compaction in the very small aneurysms....... endovascular treatment was attempted in 956 consecutive intracranial aneurysms. Of 956 aneurysms, 111 aneurysms were very small aneurysms with a maximal diameter of 3 mm or less. We conducted a retrospective analysis of angiographic and clinical outcome following coiling of very small aneurysms...... aneurysms and less than 90% aneurysm occlusion in six aneurysms. Complications occurred in the treatment of 15 aneurysms, including eight procedural ruptures, six thromboembolic events and one case of early hemorrhage. Compared with larger aneurysms, treatment of very small aneurysms was associated...

  7. Endovascular treatment for arterial injuries of skull base

    International Nuclear Information System (INIS)

    Li Tianxiao; Bai Weixing; Zai Suiting; Wang Ziliang; Xue Jiangyu

    2008-01-01

    Objective: To explore the role of endovascular techniques in treatment for arterial injuries of skull base. Methods: A total of 53 consecutive cases suffered from skull base arterial injuries were enrolled in our hospital from Oct 2004 to May 2007, including 44 male and 9 female cases with average age of 23.3 years. Thirty-nine cases presented with pulsatile exophthalmos and intracranial vascular murmur, cerchnus and dysphagia in another 9, epistaxis in the remaining 5 cases. Diagnosis of 39 carotid cavernous fistulae (CCF)and 14 carotid pseudoaneurysm were performed by angiography (DSA). Alternative endovascular procedures were performed depending on lesions characteristics and follow-up was done by telephone and outpatient work up. Results: Procedures were performed involving 56 carotid arteries in all 53 cases including 34 CCF with embolization of detachable balloon(33 cases), 3 with balloon and coils, and 3 by stent-graft placement. 8 carotid pseudoaneurysms were cured by parent artery occlusion with balloon, 2 experienced endovascular isolation with balloon and coils, and 4 with stent-graft. Follow-up for mean 9.5 months (range from 2 to 25 months) revealed that the chief symptoms of 45 cases (85%) were relieved within 6 months after the procedure but ocular movement and visual disorder remained in 8 cases (15%)till 12 months. Six pseudoaneurysms and 3 residual leak were found in reexamination, of which 2 cases underwent intervention again 2 and 3 months later due to dural arterial-venous fistula in cavernous sinus, respectively. Conclusions: Endovascular treatment is safe and effective therapeutic option with minimal invasion for skull base arterial injuries. Detachable balloon embolization is the first choice for CCF and carotid pseudoaneurysm. Spring coil packing and stent-graft implantation should be in alternation as combination for special cases. (authors)

  8. Endovascular revascularization for aortoiliac atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Aggarwal V

    2016-03-01

    Full Text Available Vikas Aggarwal,1 Stephen W Waldo,2,3 Ehrin J Armstrong2,3 1Prairie Heart Institute, St John's Hospital, Springfield, IL, 2Section of Cardiology, Denver Veterans Affairs Medical Center, 3Section of Cardiology, University of Colorado, Aurora, CO, USA Abstract: Atherosclerotic iliac artery disease is increasingly being treated with endovascular techniques. A number of new stent technologies can be utilized with high long-term patency, including self-expanding stents, balloon-expandable stents, and covered stents, but comparative data on these stent types and in more complex lesions are lacking. This article provides a review of currently available iliac stent technologies, as well as complex procedural aspects of iliac artery interventions, including approaches to the treatment of iliac bifurcation disease, long segment occlusions, choice of stent type, and treatment of iliac artery in-stent restenosis. Keywords: peripheral artery disease, iliac artery, balloon expandable stent, self expanding stent, covered stent, claudication, endovascular

  9. Transient postoperative atrial fibrillation after abdominal aortic aneurysm repair increases mortality risk

    Science.gov (United States)

    Kothari, Anai N.; Halandras, Pegge M.; Drescher, Max; Blackwell, Robert H.; Graunke, Dawn M.; Kliethermes, Stephanie; Kuo, Paul C.; Cho, Jae S.

    2016-01-01

    Objective The purpose of this study was to determine whether new-onset transient postoperative atrial fibrillation (TPAF) affects mortality rates after abdominal aortic aneurysm (AAA) repair and to identify predictors for the development of TPAF. Methods Patients who underwent open aortic repair or endovascular aortic repair for a principal diagnosis AAA were retrospectively identified using the Healthcare Cost and Utilization Project-State Inpatient Database (Florida) for 2007 to 2011 and monitored longitudinally for 1 year. Inpatient and 1-year mortality rates were compared between those with and without TPAF. TPAF was defined as new-onset atrial fibrillation that developed in the postoperative period and subsequently resolved in patients without a history of atrial fibrillation. Cox proportional hazards models, adjusted for age, gender, comorbidities, rupture status, and repair method, were used to assess 1-year survival. Predictive models were built with preoperative patient factors using Chi-squared Automatic Interaction Detector decision trees and externally validated on patients from California. Results A 3.7% incidence of TPAF was identified among 15,148 patients who underwent AAA repair. The overall mortality rate was 4.3%. The inpatient mortality rate was 12.3% in patients with TPAF vs 4.0% in those without TPAF. In the ruptured setting, the difference in mortality was similar between groups (33.7% vs 39.9%, P = .3). After controlling for age, gender, comorbid disease severity, urgency (ruptured vs nonruptured), and repair method, TPAF was associated with increased 1-year postoperative mortality (hazard ratio, 1.48; P predict an individual's probability of developing TPAF at the point of care. Conclusions The development of TPAF is associated with an increased risk of mortality in patients undergoing repair of nonruptured AAA. Predictive modeling can be used to identify those patients at highest risk for developing TPAF and guide interventions to improve

  10. Early experience with transfemoral endovascular aneurysm management (TEAM) in the treatment of aortic aneurysms

    NARCIS (Netherlands)

    Balm, R.; Eikelboom, B. C.; May, J.; Bell, P. R.; Swedenborg, J.; Collin, J.

    1996-01-01

    OBJECTIVES: To evaluate the early experience with transfemoral endovascular aortic aneurysm management using the Endovascular Grafting System. DESIGN: Multi-centre prospective evaluation of the implantation procedure and early results (median follow-up 153 days). SETTING: Department of Surgery,

  11. Combination of endovascular graft exclusion and drug therapy in AAA with hypertension or hyperglycemia.

    Science.gov (United States)

    Wang, Dile; Qu, Bihui; He, Tao

    2017-08-01

    The objective of the present study was to evaluate the efficacy of combination of endovascular graft exclusion and drugs for hypertension/hyperglycemia for the treatment of abdominal aortic aneurysm (AAA). We analyzed 156 patients with AAA. Eighty-four patients were hypertensive and 72 were hyperglycemic. After endovascular graft exclusion, hypertensive patients were divided into four groups and treated with cyclopenthiazide, reserpine, propranolol, and placebo respectively. Hyperglycemic patients were divided into three groups and treated with metformin, insulin, and placebo respectively. Body temperature and peripheral blood leukocytes were measured at day 1, 2, 7, and 14 after endovascular graft exclusion. Size of AAAs, blood pressure, and blood sugar were measured again after 1 year. In hypertensive patients, the size of AAAs reduced after endovascular graft exclusion, while the combined treatments with cyclopenthiazide, reserpine, or propranolol helped to reduce blood pressure (blood pressure decrease AAA size decreased in the control group (PAAAs reduced after endovascular graft exclusion. Combined treatment with Metformin and Insulin reduced blood sugar (control, blood sugar >7.8 mmol/L (22/24), AAA size (P7.8 mmol/L (14/24), AAA size (P7.8 mmol/L (11/24), AAA size (PAAA therapy.

  12. Endovascular Management of Iatrogenic Native Renal Arterial Pseudoaneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Sildiroglu, Onur; Saad, Wael E.; Hagspiel, Klaus D.; Matsumoto, Alan H.; Turba, Ulku Cenk, E-mail: Turba@me.com [University of Virginia Health System, Department of Radiology (United States)

    2012-12-15

    Purpose: Our purpose was to evaluate iatrogenic renal pseudoaneurysms, endovascular treatment, and outcomes. Methods: This retrospective study (2003-2011) reported the technical and clinical outcomes of endovascular therapy for renal pseudoaneurysms in eight patients (mean age, 46 (range 24-68) years). Renal parenchymal loss evaluation was based on digital subtraction angiography and computed tomography. Results: We identified eight iatrogenic renal pseudoaneurysm patients with symptoms of hematuria, pain, and hematoma after renal biopsy (n = 3), surgery (n = 3), percutaneous nephrolithotomy (n = 1), and endoscopic shock-wave lithotripsy (n = 1). In six patients, the pseudoaneurysms were small-sized (<20 mm) and peripherally located and were treated solely with coil embolization (n = 5). In one patient, coil embolization was preceded by embolization with 500-700 micron embospheres to control active bleeding. The remaining two patients had large-sized ({>=}50 mm), centrally located renal pseudoaneurysms treated with thrombin {+-} coils. Technical success with immediate bleeding cessation was achieved in all patients. There were no procedure-related deaths or complications (mean follow-up, 23.5 (range, 1-67) months). Conclusions: Treatment of renal pseudoaneurysms using endovascular approach is a relatively safe and viable option regardless of location (central or peripheral) and size of the lesions with minimal renal parenchymal sacrifice.

  13. Importance of stent-graft design for aortic arch aneurysm repair

    Directory of Open Access Journals (Sweden)

    C Singh

    2017-02-01

    Full Text Available Aneurysm of the aorta is currently treated by open surgical repair or endovascular repair. However, when the aneurysm occurs in regions between the aortic arch and proximal descending aorta, it can be a complex pathology to treat due to its intricate geometry. When complex aortic aneurysms are treated with the conventional procedures, some of the patients present with significant post-operative complications and high mortality rate. Consequently, a clinically driven hybrid innovation known as the frozen elephant trunk procedure was introduced to treat complex aortic aneurysms. Although this procedure significantly reduces mortality rate and operating time, it is still associated with complications such as endoleaks, spinal cord ischemia, renal failure and stroke. Some of these complications are consequences of a mismatch in the biomechanical behaviour of the stent-graft device and the aorta. Research on complex aneurysm repair tended to focus more on the surgical procedure than the stent-graft design. Current stent-graft devices are suitable for straight vessels. However, when used to treat aortic aneurysm with complex geometry, these devices are ineffective in restoring the normal biological and biomechanical function of the aorta. A stent-graft device with mechanical properties that are comparable with the aorta and aortic arch could possibly lead to fewer post-operative complications, thus, better outcome for patients with complex aneurysm conditions. This review highlights the influence stent-graft design has on the biomechanical properties of the aorta which in turn can contribute to complications of complex aneurysm repair. Design attributes critical for minimising postoperative biomechanical mismatch are also discussed.

  14. Impact of Smartphone Applications on Timing of Endovascular Therapy for Ischemic Stroke: A Preliminary Study.

    Science.gov (United States)

    Alotaibi, Naif M; Sarzetto, Francesca; Guha, Daipayan; Lu, Michael; Bodo, Andre; Gupta, Shaurya; Dyer, Erin; Howard, Peter; da Costa, Leodante; Swartz, Richard H; Boyle, Karl; Nathens, Avery B; Yang, Victor X D

    2017-11-01

    The metrics of imaging-to-puncture and imaging-to-reperfusion were recently found to be associated with the clinical outcomes of endovascular thrombectomy for acute ischemic stroke. However, measures for improving workflow within hospitals to achieve better timing results are largely unexplored for endovascular therapy. The aim of this study was to examine our experience with a novel smartphone application developed in house to improve our timing metrics for endovascular treatment. We developed an encrypted smartphone application connecting all stroke team members to expedite conversations and to provide synchronized real-time updates on the time window from stroke onset to imaging and to puncture. The effects of the application on the timing of endovascular therapy were evaluated with a secondary analysis of our single-center cohort. Our primary outcome was imaging-to-puncture time. We assessed the outcomes with nonparametric tests of statistical significance. Forty-five patients met our criteria for analysis among 66 consecutive patients with acute ischemic stroke who received endovascular therapy at our institution. After the implementation of the smartphone application, imaging-to-puncture time was significantly reduced (preapplication median time, 127 minutes; postapplication time, 69 minutes; P smartphone applications may reduce treatment times for endovascular therapy in acute ischemic stroke. Further studies are needed to confirm our findings. Copyright © 2017. Published by Elsevier Inc.

  15. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    International Nuclear Information System (INIS)

    Mühlenbruch, Georg; Nikoubashman, Omid; Steffen, Björn; Dadak, Mete; Palmowski, Moritz; Wiesmann, Martin

    2013-01-01

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  16. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenbruch, Georg, E-mail: gmuehlenbruch@ukaachen.de; Nikoubashman, Omid; Steffen, Bjoern; Dadak, Mete [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany); Palmowski, Moritz [RWTH Aachen University, Department of Nuclear Medicine, University Hospital (Germany); Wiesmann, Martin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany)

    2013-02-15

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  17. Outcomes of Peripheral Endovascular Interventions Based on Hospital Volume: A Mini Review of Published Literature

    Directory of Open Access Journals (Sweden)

    Samir V Patel

    2016-01-01

    Full Text Available Previous literature showed hospital procedural volume is an independent predictor for outcomes of various cardiac procedures. However, very few studies shown similar results for peripheral endovascular interventions especially peripheral atherectomy. Here we are reviewing previously published articles to provide volume-outcome relationship for peripheral atherectomy and angioplasty with or without endovascular stenting. We found higher hospital volume significantly and independently lowers in-hospital mortality, amputation rates, peri-procedural complications, length and cost of hospitalization for peripheral endovascular interventions.

  18. Early experience of endovascular treatment of peripheral vascular disease

    International Nuclear Information System (INIS)

    Ashraf, T.; Yousuf, K.; Karim, M.T.

    2015-01-01

    Atherosclerotic peripheral arterial disease (PAD) is prevalent affecting up to 16% of the population aged 55 years or older. Endovascular intervention for the treatment of limb ischemia has become the first line therapy but in Pakistan it is in embryonic stage due to dearth of trained persons and dedicated centres. This study was conducted to evaluate procedural success and early outcome of endovascular treatment of peripheral vascular disease. Methods: A prospective single arm multicentre study was conducted at the National Institute of Cardiovascular Disease and National Medical Centre, Karachi, Pakistan from January 2013 to June 2014. A total of 25 patients were enrolled in the study that underwent endovascular treatment. Out of 25 patients 23 (92%) had critical limb ischemia (CLI) as per TASC II classification (A to D) and 2 (8%) had carotid lesion with history of TIA. Patients of acute limb ischemia and stroke were excluded. Ankle brachial index (ABI) was classified as normal (0.9-1.3), mild (0.7-0.9), moderate (0.4-0.69), severe (<0.4). Outcome was taken as immediate success and symptoms, amputation of limb among CLI patients and incidence of stroke in patients with carotid artery lesion at end of six months. Results: Among aortoiliac, femoropopliteal and tibioperoneal lesions, tibioperoneal lesions at six months were found to be more symptomatic 6 (86%) and amputation 4 (57%). Two carotid lesions at follow up were asymptomatic without stroke. Conclusion: Endovascular treatment of peripheral vascular lesions, i.e., aortoiliac, femoropopliteal tibioperoneal and carotid lesions were satisfactory in immediate outcome. Tibioperoneal lesions were more symptomatic and limb amputation at six months. (author)

  19. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    International Nuclear Information System (INIS)

    Fanelli, Fabrizio; Cannavale, Alessandro; Gazzetti, Marianna; Fantozzi, Cristiano; Taurino, Maurizio; Speziale, Francesco

    2013-01-01

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient’s clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  20. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Cannavale, Alessandro [University of Rome ' Sapienza,' , Department of Radiological Sciences, Vascular and Interventional Radiology Unit (Italy); Gazzetti, Marianna [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy); Fantozzi, Cristiano; Taurino, Maurizio [University of Rome ' Sapienza,' , Department of Vascular Surgery (Italy); Speziale, Francesco [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy)

    2013-02-15

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient's clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.