WorldWideScience

Sample records for femoral tunnel length

  1. Contact area between femoral tunnel and interference screw in anatomic rectangular tunnel ACL reconstruction: a comparison of outside-in and trans-portal inside-out techniques.

    Science.gov (United States)

    Hiramatsu, Kunihiko; Mae, Tatsuo; Tachibana, Yuta; Nakagawa, Shigeto; Shino, Konsei

    2018-02-01

    The purpose of this study was to compare the femoral tunnel length, the femoral graft bending angle at the femoral tunnel aperture, and the contact area between the femoral tunnel wall and an interference screw used for fixation in anatomic rectangular tunnel anterior cruciate ligament (ACL) reconstruction (ART ACLR). The study included 149 patients with primary ACL injury who underwent ART ACLR. Preoperatively, flexion angle of the index knee was checked under general anaesthesia. Those of less than 130° of passive flexion were assigned to the outside-in (OI) technique (78 patients), while the others to the trans-portal inside-out (TP) technique (71 patients). The patients underwent computed tomography with multiplanar reconstruction at 3-5 weeks post-operatively. Femoral tunnel length, graft bending angle, and contact ratio between the IFS and femoral tunnel were assessed. P contact ratio in the OI technique was significantly larger than that in the TP technique at every point in the femoral tunnel (P contact ratio than the TP technique after ART ACLR. Retrospective comparative study, Level III.

  2. Drilling the femoral tunnel during ACL reconstruction: transtibial versus anteromedial portal techniques.

    Science.gov (United States)

    Tudisco, Cosimo; Bisicchia, Salvatore

    2012-08-01

    Incorrect bone tunnel position, particularly on the femoral side, is a frequent cause of failed anterior cruciate ligament reconstruction. Several studies have reported that drilling the femoral tunnel through the anteromedial portal allows a more anatomical placement on the lateral femoral condyle and higher knee stability than does transtibial reconstruction.In the current study, the femoral tunnel was drilled with transtibial (n=6) and anteromedial (n=6) portal techniques in 12 cadaveric knees. With appropriate landmarks inserted into bone tunnels, the direction and length of the tunnels were determined on anteroposterior and lateral radiographs. Knee stability was evaluated with a KT1000 arthrometer (MEDmetric Corporation, San Diego, California) and pivot shift test, comparing the pre- and postoperative values of both techniques. Finally, all knees were dissected to enhance vision of the insertion of the reconstructed ligament. The anteromedial portal technique led to better placement of the femoral tunnel in the coronal and sagittal planes, with higher knee stability according to the pivot shift test but not the KT1000 arthrometer. Anatomical and clinical results reported in the literature on transtibial and anteromedial portal techniques are controversial, but most of studies report better results with the anteromedial portal technique, especially regarding rotational stability. The current cadaveric study showed that the anteromedial portal technique provided better tunnel placement on the lateral femoral condyle in the coronal and sagittal planes, with an improvement in the rotational stability of the knee. Copyright 2012, SLACK Incorporated.

  3. Editorial Commentary: The All-Epiphyseal Anterior Cruciate Ligament Distal Femoral Approach: Sockets or Tunnels?

    Science.gov (United States)

    Cordasco, Frank A

    2018-05-01

    I believe that the distal femoral approach for anterior cruciate ligament reconstruction in the skeletally immature athlete with 3 to 6 years of remaining growth is best performed with an all-inside, all-epiphyseal technique using sockets rather than an outside-in approach creating tunnels. A shorter socket rather than a longer tunnel exposes a smaller surface area of the lateral distal femoral physis to potential compromise and resultant valgus malalignment. In addition, exiting the lateral femoral aspect of the epiphysis with a full-diameter tunnel as compared with a smaller diameter drill hole used to prepare a socket places the posterior articular cartilage, the lateral collateral ligament and anterolateral ligament footprints, and the popliteus tendon insertion at risk. My preference for sockets is also related to my belief that they provide a superior biologic milieu for graft incorporation compared with a full-length tunnel with the attendant violation of the lateral femoral cortex of the epiphysis. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  4. Does flexible tunnel drilling affect the femoral tunnel angle measurement after anterior cruciate ligament reconstruction?

    Science.gov (United States)

    Muller, Bart; Hofbauer, Marcus; Atte, Akere; van Dijk, C Niek; Fu, Freddie H

    2015-12-01

    To quantify the mean difference in femoral tunnel angle (FTA) as measured on knee radiographs between rigid and flexible tunnel drilling after anatomic anterior cruciate ligament (ACL) reconstruction. Fifty consecutive patients that underwent primary anatomic ACL reconstruction with a single femoral tunnel drilled with a flexible reamer were included in this study. The control group was comprised of 50 patients all of who underwent primary anatomic ACL reconstruction with a single femoral tunnel drilled with a rigid reamer. All femoral tunnels were drilled through a medial portal to ensure anatomic tunnel placement. The FTA was determined from post-operative anterior-to-posterior (AP) radiographs by two independent observers. A 5° difference between the two mean FTA was considered clinically significant. The average FTA, when drilled with a rigid reamer, was 42.0° ± 7.2°. Drilling with a flexible reamer resulted in a mean FTA of 44.7° ± 7.0°. The mean difference of 2.7° was not statistically significant. The intraclass correlation coefficient for inter-tester reliability was 0.895. The FTA can be reliably determined from post-operative AP radiographs and provides a useful and reproducible metric for characterizing femoral tunnel position after both rigid and flexible femoral tunnel drilling. This has implications for post-operative evaluation and preoperative treatment planning for ACL revision surgery. IV.

  5. Does flexible tunnel drilling affect the femoral tunnel angle measurement after anterior cruciate ligament reconstruction?

    NARCIS (Netherlands)

    Muller, Bart; Hofbauer, Marcus; Atte, Akere; van Dijk, C. Niek; Fu, Freddie H.

    2015-01-01

    To quantify the mean difference in femoral tunnel angle (FTA) as measured on knee radiographs between rigid and flexible tunnel drilling after anatomic anterior cruciate ligament (ACL) reconstruction. Fifty consecutive patients that underwent primary anatomic ACL reconstruction with a single femoral

  6. All-Epiphyseal Anterior Cruciate Ligament Femoral Tunnel Drilling: Avoiding Injury to the Physis, Lateral Collateral Ligament, Anterolateral Ligament, and Popliteus-A 3-Dimensional Computed Tomography Study.

    Science.gov (United States)

    Shea, Kevin G; Cannamela, Peter C; Fabricant, Peter D; Terhune, Elizabeth B; Polousky, John D; Milewski, Matthew D; Anderson, Allen F; Ganley, Theodore J

    2018-01-25

    To investigate the relation of the at-risk structures (distal femoral physis, lateral collateral ligament, anterolateral ligament, popliteus, and articular cartilage) during all-epiphyseal femoral tunnel drilling. A second purpose was 2-fold: (1) to develop recommendations for tunnel placement and orientation that anatomically reconstruct the anterior cruciate ligament (ACL) while minimizing the risk of injury to these at-risk structures, and (2) to allow for maximal tunnel length to increase the amount of graft in the socket to facilitate healing. Three-dimensional models of 6 skeletally immature knees (aged 7-11 years) were reconstructed from computed tomography and used to simulate all-epiphyseal femoral tunnels. Tunnels began within the ACL footprint and were directed laterally or anterolaterally, with the goal of avoiding injury to at-risk structures. The spatial relation between the ideal tunnel and these structures was evaluated. Full-length tunnels and partial length condyle sockets were simulated in the models using the same trajectories. An anterolateral tunnel could be placed to avoid direct injury to lateral structures. The safe zone on the anterolateral aspect of the femur was larger than that of a tunnel with a direct lateral trajectory (median 127 mm 2 vs 83 mm 2 , P = .028). Anterolateral tunnels were longer than direct lateral tunnels (median 30 mm vs 24 mm, P = .041). Safe angles for anterolateral tunnels were 34° to 40° from the posterior condylar axis; direct lateral tunnels were drilled 4° to 9° from the posterior condylar axis. Sockets could be placed without direct injury to structures at risk with either orientation. An all-epiphyseal ACL femoral tunnel can be placed without causing direct injury to at-risk structures. A tunnel angled anterolaterally from the ACL origin is longer and has a larger safe zone compared with the direct lateral tunnel. The largest safe zone for femoral all-epiphyseal ACL drilling was (1) anterior to

  7. 3D-Printed Patient-Specific ACL Femoral Tunnel Guide from MRI.

    Science.gov (United States)

    Rankin, Iain; Rehman, Haroon; Frame, Mark

    2018-01-01

    Traditional ACL reconstruction with non-anatomic techniques can demonstrate unsatisfactory long-term outcomes with regards instability and the degenerative knee changes observed with these results. Anatomic ACL reconstruction attempts to closely reproduce the patient's individual anatomic characteristics with the aim of restoring knee kinematics, in order to improve patient short and long-term outcomes. We designed an arthroscopic, patient-specific, ACL femoral tunnel guide to aid anatomical placement of the ACL graft within the femoral tunnel. The guide design was based on MRI scan of the subject's uninjured contralateral knee, identifying the femoral footprint and its anatomical position relative to the borders of the femoral articular cartilage. Image processing software was used to create a 3D computer aided design which was subsequently exported to a 3D-printing service. Transparent acrylic based photopolymer, PA220 plastic and 316L stainless steel patient-specific ACL femoral tunnel guides were created; the models produced were accurate with no statistical difference in size and positioning of the center of the ACL femoral footprint guide to MRI ( p =0.344, p =0.189, p =0.233 respectively). The guides aim to provide accurate marking of the starting point of the femoral tunnel in arthroscopic ACL reconstruction. This study serves as a proof of concept for the accurate creation of 3D-printed patient-specific guides for the anatomical placement of the femoral tunnel during ACL reconstruction.

  8. Influence of knee flexion angle and transverse drill angle on creation of femoral tunnels in double-bundle anterior cruciate ligament reconstruction using the transportal technique: Three-dimensional computed tomography simulation analysis.

    Science.gov (United States)

    Choi, Chong Hyuk; Kim, Sung-Jae; Chun, Yong-Min; Kim, Sung-Hwan; Lee, Su-Keon; Eom, Nam-Kyu; Jung, Min

    2018-01-01

    The purpose of this study was to find appropriate flexion angle and transverse drill angle for optimal femoral tunnels of anteromedial (AM) bundle and posterolateral (PL) bundle in double-bundle ACL reconstruction using transportal technique. Thirty three-dimensional knee models were reconstructed. Knee flexion angles were altered from 100° to 130° at intervals of 10°. Maximum transverse drill angle (MTA), MTA minus 10° and 20° were set up. Twelve different tunnels were determined by four flexion angles and three transverse drill angles for each bundle. Tunnel length, wall breakage, inter-tunnel communication and graft-bending angle were assessed. Mean tunnel length of AM bundle was >30mm at 120° and 130° of flexion in all transverse drill angles. Mean tunnel length of PL bundle was >30mm during every condition. There were ≥1 cases of wall breakage except at 120° and 130° of flexion with MTA for AM bundle. There was no case of wall breakage for PL bundle. Considering inter-tunnel gap of >2mm without communication and obtuse graft-bending angle, 120° of flexion and MTA could be recommended as optimal condition for femoral tunnels of AM and PL bundles. Flexion angle and transverse drill angle had combined effect on femoral tunnel in double-bundle ACL reconstruction using transportal technique. Achieving flexion angle of 120° and transverse drill angle close to the medial femoral condyle could be recommended as optimal condition for femoral tunnels of AM and PL bundles to avoid insufficient tunnel length, wall breakage, inter-tunnel communication and acute graft-bending angle. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Peak stresses shift from femoral tunnel aperture to tibial tunnel aperture in lateral tibial tunnel ACL reconstructions: a 3D graft-bending angle measurement and finite-element analysis.

    Science.gov (United States)

    Van Der Bracht, Hans; Tampere, Thomas; Beekman, Pieter; Schepens, Alexander; Devriendt, Wouter; Verdonk, Peter; Victor, Jan

    2018-02-01

    To investigate the effect of tibial tunnel orientation on graft-bending angle and stress distribution in the ACL graft. Eight cadaveric knees were scanned in extension, 45°, 90°, and full flexion. 3D reconstructions with anatomically placed anterior cruciate ligament (ACL) grafts were constructed with Mimics 14.12 ® . 3D graft-bending angles were measured for classic medial tibial tunnels (MTT) and lateral tibial tunnels (LTT) with different drill-guide angles (DGA) (45°, 55°, 65°, and 75°). A pivot shift was performed on 1 knee in a finite-element analysis. The peak stresses in the graft were calculated for eight different tibial tunnel orientations. In a classic anatomical ACL repair, the largest graft-bending angle and peak stresses are seen at the femoral tunnel aperture. The use of a different DGA at the tibial side does not change the graft-bending angle at the femoral side or magnitude of peak stresses significantly. When using LTT, the largest graft-bending angles and peak stresses are seen at the tibial tunnel aperture. In a classic anatomical ACL repair, peak stresses in the ACL graft are found at the femoral tunnel aperture. When an LTT is used, peak stresses are similar compared to classic ACL repairs, but the location of the peak stress will shift from the femoral tunnel aperture towards the tibial tunnel aperture. the risk of graft rupture is similar for both MTTs and LTTs, but the location of graft rupture changes from the femoral tunnel aperture towards the tibial tunnel aperture, respectively. I.

  10. Transportal femoral drilling creates more horizontal ACL graft orientation compared to transtibial drilling: A 3D CT imaging study.

    Science.gov (United States)

    Clockaerts, S; Van Haver, A; Verhaegen, J; Vuylsteke, K; Leenders, T; Lagae, K C; Verdonk, P

    2016-06-01

    The principle of anatomic anterior cruciate ligament (ACL) reconstruction is to create a femoral and tibial tunnel that resembles the insertion of the native ACL. Anatomic reconstruction leads to a more horizontal graft orientation that provides more rotational stability. The aim of this study is to investigate the best method to achieve anatomical reconstruction of femoral insertion of the ACL and thus, a more horizontal orientation of the ACL. We compared tunnel position and orientation between transportal femoral drilling technique and transtibial technique. Thirty-two patients were included. Post-operative CT scans were obtained and femur, tibia and ACL tunnels were reconstructed. The position and orientation of tibial and femoral tunnels were quantified using the quadrant method, and femoral tunnel length, ellipticity and posterior wall breakage were assessed. We also investigated clinical outcome. Analyses show that transportal drilled femoral tunnels were situated significantly lower than transtibial drilled tunnels (p<0.0001), resulting in a significantly more horizontal oriented ACL in the transportal group in coronal (p<0.0001) and sagittal plane (p=0.01). No differences were observed in depth of femoral tunnel position (p=0.44). Femoral tunnel length was shorter in the transportal group (p=0.01) with a more ellipsoidal femoral aperture (p=0.01). There were no differences between both groups in tibial position. There were no differences in clinical outcome measure between the transportal and transtibial groups. This study indicates that transportal drilling of the femoral tunnel leads to a more horizontal graft orientation of the ACL, without differences in clinical outcome. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Post-operative 3D CT feedback improves accuracy and precision in the learning curve of anatomic ACL femoral tunnel placement.

    Science.gov (United States)

    Sirleo, Luigi; Innocenti, Massimo; Innocenti, Matteo; Civinini, Roberto; Carulli, Christian; Matassi, Fabrizio

    2018-02-01

    To evaluate the feedback from post-operative three-dimensional computed tomography (3D-CT) on femoral tunnel placement in the learning process, to obtain an anatomic anterior cruciate ligament (ACL) reconstruction. A series of 60 consecutive patients undergoing primary ACL reconstruction using autologous hamstrings single-bundle outside-in technique were prospectively included in the study. ACL reconstructions were performed by the same trainee-surgeon during his learning phase of anatomic ACL femoral tunnel placement. A CT scan with dedicated tunnel study was performed in all patients within 48 h after surgery. The data obtained from the CT scan were processed into a three-dimensional surface model, and a true medial view of the lateral femoral condyle was used for the femoral tunnel placement analysis. Two independent examiners analysed the tunnel placements. The centre of femoral tunnel was measured using a quadrant method as described by Bernard and Hertel. The coordinates measured were compared with anatomic coordinates values described in the literature [deep-to-shallow distance (X-axis) 28.5%; high-to-low distance (Y-axis) 35.2%]. Tunnel placement was evaluated in terms of accuracy and precision. After each ACL reconstruction, results were shown to the surgeon to receive an instant feedback in order to achieve accurate correction and improve tunnel placement for the next surgery. Complications and arthroscopic time were also recorded. Results were divided into three consecutive series (1, 2, 3) of 20 patients each. A trend to placing femoral tunnel slightly shallow in deep-to-shallow distance and slightly high in high-to-low distance was observed in the first and the second series. A progressive improvement in tunnel position was recorded from the first to second series and from the second to the third series. Both accuracy (+52.4%) and precision (+55.7%) increased from the first to the third series (p process to improve accuracy and precision of femoral

  12. Transphyseal ACL Reconstruction in Skeletally Immature Patients: Does Independent Femoral Tunnel Drilling Place the Physis at Greater Risk Compared With Transtibial Drilling?

    Science.gov (United States)

    Cruz, Aristides I; Lakomkin, Nikita; Fabricant, Peter D; Lawrence, J Todd R

    2016-06-01

    Most studies examining the safety and efficacy of transphyseal anterior cruciate ligament (ACL) reconstruction for skeletally immature patients utilize transtibial drilling. Independent femoral tunnel drilling may impart a different pattern of distal femoral physeal involvement. To radiographically assess differences in distal femoral physeal disruption between transtibial and independent femoral tunnel drilling. We hypothesized that more oblique tunnels associated with independent drilling involve a significantly larger area of physeal disruption compared with vertically oriented tunnels. Cross-sectional study; Level of evidence, 3. We analyzed skeletally immature patients aged between 10 and 15 years who underwent transphyseal ACL reconstruction utilizing an independent femoral tunnel drilling technique between January 1, 2008, and March 31, 2011. These patients were matched with a transtibial technique cohort based on age and sex. Radiographic measurements were recorded from preoperative magnetic resonance imaging and postoperative radiographs. Ten patients in each group were analyzed. There were significant differences between independent drilling and transtibial drilling cohorts in the estimated area of physeal disruption (1.64 vs 0.74 cm(2); P drilling technique disrupt a larger area of the distal femoral physis and create more eccentric tunnels compared with a transtibial technique. As most studies noting the safety of transphyseal ACL reconstruction have utilized a central, vertical femoral tunnel, surgeons should be aware that if an independent femoral tunnel technique is utilized during transphyseal ACL reconstruction, more physeal tissue is at risk and tunnels are more eccentrically placed across the physis when drilling at more horizontal angles. Prior studies have shown that greater physeal involvement and eccentric tunnels may increase the risk of growth disturbance.

  13. Patency of Femoral Tunneled Hemodialysis Catheters and Factors Predictive of Patency Failure

    International Nuclear Information System (INIS)

    Burton, Kirsteen R.; Guo, Lancia L. Q.; Tan, Kong T.; Simons, Martin E.; Sniderman, Kenneth W.; Kachura, John R.; Beecroft, John R.; Rajan, Dheeraj K.

    2012-01-01

    Purpose: To determine the patency rates of and factors associated with increased risk of patency failure in patients with femoral vein tunneled hemodialysis catheters. Methods: All femoral tunneled catheter insertions from 1996 to 2006 were reviewed, during which time 123 catheters were inserted. Of these, 66 were exchanges. Patients with femoral catheter failure versus those with femoral catheter patency were compared. Confounding factors, such as demographic and procedural factors, were incorporated and assessed using univariate and multivariable Cox proportional hazards regression analyses. Results: Mean catheter primary patency failure time was 96.3 days (SE 17.9 days). Primary patency at 30, 60, 90, and 180 days was 53.8%, 45.4%, 32.1%, and 27.1% respectively. Crude rates of risk of catheter failure did not suggest a benefit for patients receiving catheters introduced from one side versus the other, but more cephalad location of catheter tip was associated with improved patency. Multivariate analysis showed that patients whose catheters were on the left side (p = 0.009), were of increasing age at the time of insertion (p = 0.002) and that those who had diabetes (p = 0.001) were at significantly greater risk of catheter failure. The catheter infection rate was 1.4/1000 catheter days. Conclusion: Patients who were of a more advanced age and had diabetes were at greater risk of femoral catheter failure, whereas those who received femoral catheters from the right side were less at risk of catheter failure.

  14. Accuracy of a computer-assisted planning and placement system for anatomical femoral tunnel positioning in anterior cruciate ligament reconstruction

    NARCIS (Netherlands)

    Luites, J.W.H.; Wymenga, A.B.; Blankevoort, L.; Eygendaal, D.; Verdonschot, Nicolaas Jacobus Joseph

    2014-01-01

    Background Femoral tunnel positioning is a difficult, but important factor in successful anterior cruciate ligament (ACL) reconstruction. Computer navigation can improve the anatomical planning procedure besides the tunnel placement procedure. Methods The accuracy of the computer-assisted femoral

  15. Early integration of a bone plug in the femoral tunnel in rectangular tunnel ACL reconstruction with a bone-patellar tendon-bone graft: a prospective computed tomography analysis.

    Science.gov (United States)

    Suzuki, Tomoyuki; Shino, Konsei; Nakagawa, Shigeto; Nakata, Ken; Iwahashi, Takehiko; Kinugasa, Kazutaka; Otsubo, Hidenori; Yamashita, Toshihiko

    2011-12-01

    The purpose of this prospective study was to evaluate how early the bone plug was integrated into the rectangular femoral tunnel after anatomical ACL reconstruction using a bone-patellar tendon-bone (BTB) graft via a rectangular tunnel (RT BTB ACL-R). Twenty consecutive patients who had undergone the reconstruction procedure were evaluated by CT scans at 4 and 8 weeks postoperatively. In each scan, 30 slices for multiplanar reconstruction were collected parallel to the long axis of the parallelepiped femoral tunnel and perpendicular to the tendinous plane of the bone plug. Each slice was classified as "complete," indicating no visible gap between the plug and the tunnel wall or trabecular continuity or "incomplete," showing a visible gap. Bone plug-tunnel integration was evaluated as "excellent," "good," "fair," or "poor" for >20, 11-20, 5-10, and values at the anterior interface between the bone plug and the tunnel wall were also measured on both scans. The mean changes in CT value at 8 weeks were significantly lower than those at 4 weeks. This study shows that bone plug-femoral tunnel integration was almost complete by 8 weeks after surgery using RT BTB ACL-R.

  16. Influence of the different anteromedial portal on femoral tunnel orientation during anatomic ACL reconstruction

    Directory of Open Access Journals (Sweden)

    Dong-Kyu Moon

    2017-05-01

    Conclusions: In anatomic ACL reconstruction, a mal-positioned AM portal can cause abnormal tunnel orientation, which may lead to mechanical failure during ACL reconstruction. Therefore, it is important to select accurate AM portal positioning, and possibly using an AAM portal by measuring an accurate position when drilling a femoral tunnel in anatomic ACL reconstruction.

  17. Knee rotation influences the femoral tunnel angle measurement after anterior cruciate ligament reconstruction: a 3-dimensional computed tomography model study

    Science.gov (United States)

    Tang, Jing; Thorhauer, Eric; Marsh, Chelsea; Fu, Freddie H.

    2013-01-01

    Purpose Femoral tunnel angle (FTA) has been proposed as a metric for evaluating whether ACL reconstruction was performed anatomically. In clinic, radiographic images are typically acquired with an uncertain amount of internal/external knee rotation. The extent to which knee rotation will influence FTA measurement is unclear. Furthermore, differences in FTA measurement between the two common positions (0° and 45° knee flexion) have not been established. The purpose of this study was to investigate the influence of knee rotation on FTA measurement after ACL reconstruction. Methods Knee CT data from 16 subjects were segmented to produce 3D bone models. Central axes of tunnels were identified. The 0° and 45° flexion angles were simulated. Knee internal/external rotations were simulated in a range of ±20°. FTA was defined as the angle between the tunnel axis and femoral shaft axis, orthogonally projected into the coronal plane. Results Femoral tunnel angle was positively/negatively correlated with knee rotation angle at 0°/45° knee flexion. At 0° knee flexion, FTA for anterio-medial (AM) tunnels was significantly decreased at 20° of external knee rotation. At 45° knee flexion, more than 16° external or 19° internal rotation significantly altered FTA measurements for single-bundle tunnels; smaller rotations (±9° for AM, ±5° for PL) created significant errors in FTA measurements after double-bundle reconstruction. Conclusion Femoral tunnel angle measurements were correlated with knee rotation. Relatively small imaging malalignment introduced significant errors with knee flexed 45°. This study supports using the 0° flexion position for knee radiographs to reduce errors in FTA measurement due to knee internal/external rotation. Level of evidence Case–control study, Level III. PMID:23589127

  18. Disadvantages and advantages of transtibial technique for creating the anterior cruciate ligament femoral socket.

    Science.gov (United States)

    Robin, Brett N; Lubowitz, James H

    2014-10-01

    Anterior cruciate ligament (ACL) femoral socket techniques have distinct advantages and disadvantages when considering the following techniques: transtibial, anteromedial portal, outside-in, and outside-in retroconstruction. There is no one perfect technique and we have an incomplete understanding of anatomical, biomechanical, isometry, stability, and clinical outcomes. Our primary focus is transtibial technique for creating the ACL femoral socket. Advantages include less invasive, isometric graft placement, stable Lachman exam, and minimal graft impingement with the tunnel and notch. Disadvantages include nonanatomic vertical graft placement that can cause rotational instability and positive pivot shift, interference screw divergence, graft-tunnel length mismatch, femoral socket constraint, posterior cruciate ligament impingement, and a short, oblique tibial tunnel that may undermine the medial plateau in an attempt to achieve anatomic ACL reconstruction. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Double incision iso-anatomical ACL reconstruction: the freedom to place the femoral tunnel within the anatomical attachment site without exception.

    Science.gov (United States)

    Arnold, Markus P; Duthon, Victoria; Neyret, Philippe; Hirschmann, Michael T

    2013-02-01

    The present paper describes the rationale behind the surgical technique and the clinical results of the iso-anatomical, single bundle bone patellar-tendon bone anterior cruciate ligament (ACL) reconstruction. Using a second incision on the distal lateral femur an outside-in femoral tunnel is drilled. Guided by a special aiming device it is possible to place the femoral tunnel in the centre of the ACL footprint in every single case. Since every crucial step of the procedure is under visual control, the technique is safe and reliable, which is mirrored by good clinical results.

  20. Reliability and reproducibility of several methods of arthroscopic assessment of femoral tunnel position during anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Ilahi, Omer A; Mansfield, David J; Urrea, Luis H; Qadeer, Ali A

    2014-10-01

    To assess interobserver and intraobserver agreement of estimating anterior cruciate ligament (ACL) femoral tunnel positioning arthroscopically using circular and linear (noncircular) estimation methods and to determine whether overlay template visual aids improve agreement. Standardized intraoperative pictures of femoral tunnel pilot holes (taken with a 30° arthroscope through an anterolateral portal at 90° of knee flexion with horizontal being parallel to the tibial surface) in 27 patients undergoing single-bundle ACL reconstruction were presented to 3 fellowship-trained arthroscopists on 2 separate occasions. On both viewings, each surgeon estimated the femoral tunnel pilot hole location to the nearest half-hour mark using a whole clock face and half clock face, to the nearest 15° using a whole compass and half compass, in the top or bottom half of a linear quadrant, and in the top or bottom half of a linear trisector. Evaluations were performed first without and then with an overlay template of each estimation method. The average difference among reviewers was quite similar for all 4 circular methods with the use of visual aids. Without overlay template visual aids, pair-wise κ statistic values for interobserver agreement ranged from -0.14 to 0.56 for the whole clock face and from 0.16 to 0.42 for the half clock face. With overlay visual guides, interobserver agreement ranged from 0.29 to 0.63 for the whole clock face and from 0.17 to 0.66 for the half clock face. The quadrant method's interobserver agreement ranged from 0.22 to 0.60, and that of the trisection method ranged from 0.17 to 0.57. Neither linear estimation method's reliability uniformly improved with the use of overlay templates. Intraobserver agreement without overlay templates ranged from 0.17 to 0.49 for the whole clock face, 0.11 to 0.47 for the half clock face, 0.01 to 0.66 for the quadrant method, and 0.20 to 0.57 for the trisection method. Use of overlay templates did not uniformly

  1. Tibial and Femoral Tunnel Changes After ACL Reconstruction: A Prospective 2-Year Longitudinal MRI Study.

    Science.gov (United States)

    Weber, Alexander E; Delos, Demetris; Oltean, Hanna N; Vadasdi, Katherine; Cavanaugh, John; Potter, Hollis G; Rodeo, Scott A

    2015-05-01

    Tunnel widening after anterior cruciate ligament reconstruction (ACL-R) is a well-accepted and frequent phenomenon, yet little is known regarding its origin or natural history. To prospectively evaluate the cross-sectional area (CSA) changes in tibial and femoral bone tunnels after ACL-R with serial MRI. Case series; Level of evidence, 4. Patients underwent arthroscopic ACL-R with the same surgeon, surgical technique, and rehabilitation protocol. Each patient underwent preoperative dual-energy x-ray absorptiometry and clinical evaluation, as well as postoperative time zero MRI followed by subsequent MRI and clinical examination, including functional and subjective outcome tests, at 6, 12, 24, 52, and 104 weeks. Tibial and femoral tunnel CSA was measured on each MRI at tunnel aperture (ttA and ftA), midsection (ttM and ftM), and exit (ttE and ftE). Logistic regression modeling was used to examine the predictive value of demographic data and preoperative bone quality (as measured by dual-energy x-ray absorptiometry) on functional outcome scores, manual and instrumented laxity measurements, and changes in tunnel area over time. Eighteen patients (including 12 men), mean age 35.5±8.7 years, underwent ACL-R. There was significant tunnel expansion at ttA and ftA sites 6 weeks postoperatively (P=.024 and .0045, respectively). Expansion continued for 24 weeks, with progressive tunnel narrowing thereafter. Average ttA CSA was significantly larger than ftA CSA at all times. The ttM significantly expanded after 6 weeks (P=.06); continued expansion to week 12 was followed by 21 months of reduction in tunnel diameter. The ftM and both ttE and ftE sites decreased in CSA over the 2 years. Median Lysholm and International Knee Documentation Committee scores significantly improved at final follow-up (P=.0083 and 1 year from time of injury) predicted increased tunnel widening and accelerated expansion in CSA (Pclinical outcome. Younger age, male sex, and delay from injury to ACL

  2. Factors that influence femoral neck length. Analysis of 1543 patients with advanced osteoarthritis of the hip

    NARCIS (Netherlands)

    Prins, Wybren; Kollen, Boudewijn J.; Ettema, Harmen B.; Verheyen, Cees C. P. M.

    2013-01-01

    Background and purpose: There is little known about the relationship between patient characteristic and the variance in geometrical properties of the femoral neck. The length of the femoral neck is relevant when considering a femoral neck preserving hip replacement. Based on surgical experience we

  3. Variability in ACL tunnel placement: observational clinical study of surgeon ACL tunnel variability.

    Science.gov (United States)

    Wolf, Brian R; Ramme, Austin J; Wright, Rick W; Brophy, Robert H; McCarty, Eric C; Vidal, Armando R; Parker, Richard D; Andrish, Jack T; Amendola, Annunziato

    2013-06-01

    Multicenter and multisurgeon cohort studies on anterior cruciate ligament (ACL) reconstruction are becoming more common. Minimal information exists on intersurgeon and intrasurgeon variability in ACL tunnel placement. Purpose/ The purpose of this study was to analyze intersurgeon and intrasurgeon variability in ACL tunnel placement in a series of The Multicenter Orthopaedic Outcomes Network (MOON) ACL reconstruction patients and in a clinical cohort of ACL reconstruction patients. The hypothesis was that there would be minimal variability between surgeons in ACL tunnel placement. Cross-sectional study; Level of evidence, 3. Seventy-eight patients who underwent ACL reconstruction by 8 surgeons had postoperative imaging with computed tomography, and ACL tunnel location and angulation were analyzed using 3-dimensional surface processing and measurement. Intersurgeon and intrasurgeon variability in ACL tunnel placement was analyzed. For intersurgeon variability, the range in mean ACL femoral tunnel depth between surgeons was 22%. For femoral tunnel height, there was a 19% range. Tibial tunnel location from anterior to posterior on the plateau had a 16% range in mean results. There was only a small range of 4% for mean tibial tunnel location from the medial to lateral dimension. For intrasurgeon variability, femoral tunnel depth demonstrated the largest ranges, and tibial tunnel location from medial to lateral on the plateau demonstrated the least variability. Overall, surgeons were relatively consistent within their own cases. Using applied measurement criteria, 85% of femoral tunnels and 90% of tibial tunnels fell within applied literature-based guidelines. Ninety-one percent of the axes of the femoral tunnels fell within the boundaries of the femoral footprint. The data demonstrate that surgeons performing ACL reconstructions are relatively consistent between each other. There is, however, variability of average tunnel placement up to 22% of mean condylar depth

  4. A comparison of locked versus nonlocked Enders rods for length unstable pediatric femoral shaft fractures.

    Science.gov (United States)

    Ellis, Henry Bone; Ho, Christine A; Podeszwa, David A; Wilson, Philip L

    2011-12-01

    Stainless steel flexible Enders rods have been used for intramedullary fixation of pediatric femur fractures with good success. Despite intraoperative anatomic alignment, length unstable femur fractures can present postoperatively with fracture shortening. The purpose of this study was to review all length unstable pediatric femoral shaft fractures in which Enders rods were used and compare those that were locked to those that were not locked. A retrospective clinical and radiographic review of all patients at a single institution undergoing flexible intramedullary fixation for length unstable femoral shaft fractures from 2001 to 2008. A length unstable fracture was defined as either a comminuted fracture or a spiral fracture longer than twice the diameter of the femoral shaft. A total of 107 length unstable femoral shaft fractures fixed with Enders rods were identified, of which 37 cases (35%) had both Enders rods "locked" through the eyelet in the distal femur with a 2.7 mm fully threaded cortical screw. Patient demographics, clinical course, complications, fracture characteristics, and radiographic outcomes were compared for the locked and nonlocked groups. There were no statistical differences between the groups in demographic data, operative variables, fracture pattern, fracture location, time to union, femoral alignment, or major complications. Shortening of the femur and nail migration measured at 1 to 6 weeks postoperatively was significantly greater for the nonlocked cases. The medial and lateral locked Enders rods moved 1.3 and 1.9 mm, respectively, and the unlocked Enders each moved 12.1 mm (P < 0.05). At final follow-up there were significantly more (P < 0.05) clinical complaints in nonlocked group, including limp, clinical shortening, and painful palpable rods. Locking Enders rods for length unstable pediatric fractures is an excellent option to prevent shortening and resulted in no additional complications, added surgical time, or increased blood loss

  5. Positioning of the femoral tunnel for arthroscopic reconstruction of the anterior cruciate ligament: comparative study of 2 techniques Posicionamento do túnel femoral na reconstrução artroscópica do LCA: estudo comparativo de duas técnicas

    Directory of Open Access Journals (Sweden)

    Roberto Freire da Mota Albuquerque

    2007-01-01

    Full Text Available OBJECTIVE: To compare the accuracy of positioning of the femoral tunnel in reconstructing the anterior cruciate ligament by means of 2 techniques: tibial tunnel and anteromedial portal. METHOD: Femoral tunnels were drilled in 20 knees from human cadavers by means of arthroscopy. Group I had the femoral tunnel drilled via a trans-tibial tunnel, and Group II via the anteromedial portal. Four variables were measured: A posterior wall thickness; B tunnel positioning at the notch; C tunnel inclination in relation to the femoral axis; and D distance between the wire guide exit and the lateral epicondyle. RESULTS: As above, respectively, A 2.23 mm for group I and 2.36 mm for group II (P =.54; B 25.5° for group I and 30.0° for group II (P =.23; C 23.9° for group I and 32.0° for group II (P =.02; D 7.8 cm for group I and 3.9 cm for group II (P OBJETIVO: Comparar a acurácia do posicionamento do túnel femoral na reconstrução do ligamento cruzado anterior através de duas vias: túnel tibial e portal ântero - medial. MÉTODO: Foram perfurados túneis femorais em vinte joelhos de cadáveres humanos por via artroscópica. Grupo I: túnel femoral por acesso trans túnel tibial. Grupo II: via portal ântero-medial. Quatro variáveis foram estudadas: A espessura da parede posterior; B posicionamento do túnel no intercôndilo; C angulação do túnel em relação ao eixo do fêmur; D distância entre a saída do fio guia e o epicôndilo lateral. RESULTADO: A grupo I: 2,23 mm, grupo II: 2,36 mm (p=0,543; B grupo I: 25,5º, grupo II: 30º (p=0,226; C grupo I: 23,9º, grupo II: 32º (p= 0,014; D grupo I: 7,8 cm, grupo II 3,9 cm (p<0,001. CONCLUSÃO: As duas técnicas obteveram o posicionamento desejado da entrada do túnel femoral e espessura adequada da cortical posterior. A perfuração via portal ântero-medial pode propiciar maior proteção contra rotura da parede posterior.

  6. Advantages and Disadvantages of Transtibial, Anteromedial Portal, and Outside-In Femoral Tunnel Drilling in Single-Bundle Anterior Cruciate Ligament Reconstruction: A Systematic Review.

    Science.gov (United States)

    Robin, Brett N; Jani, Sunil S; Marvil, Sean C; Reid, John B; Schillhammer, Carl K; Lubowitz, James H

    2015-07-01

    Controversy exists regarding the best method for creating the knee anterior cruciate ligament (ACL) femoral tunnel or socket. The purpose of this study was to systematically review the risks, benefits, advantages, and disadvantages of the endoscopic transtibial (TT) technique, anteromedial portal technique, outside-in technique, and outside-in retrograde drilling technique for creating the ACL femoral tunnel. A PubMed search of English-language studies published between January 1, 2000, and February 17, 2014, was performed using the following keywords: "anterior cruciate ligament" AND "femoral tunnel." Included were studies reporting risks, benefits, advantages, and/or disadvantages of any ACL femoral technique. In addition, references of included articles were reviewed to identify potential studies missed in the original search. A total of 27 articles were identified through the search. TT technique advantages include familiarity and proven long-term outcomes; disadvantages include the risk of nonanatomic placement because of constrained (TT) drilling. Anteromedial portal technique advantages include unconstrained anatomic placement; disadvantages include technical challenges, short tunnels or sockets, and posterior-wall blowout. Outside-in technique advantages include unconstrained anatomic placement; disadvantages include the need for 2 incisions. Retrograde drilling technique advantages include unconstrained anatomic placement, as well as all-epiphyseal drilling in skeletally immature patients; disadvantages include the need for fluoroscopy for all-epiphyseal drilling. There is no one, single, established "gold-standard" technique for creation of the ACL femoral socket. Four accepted techniques show diverse and subjective advantages, disadvantages, risks, and benefits. Level V, systematic review of Level II through V evidence. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  7. The relationship of lateral anatomic structures to exiting guide pins during femoral tunnel preparation utilizing an accessory medial portal.

    Science.gov (United States)

    Farrow, Lutul D; Parker, Richard D

    2010-06-01

    Anatomic reconstruction of the anterior cruciate ligament through an accessory medial portal has become increasingly popular. The purpose of this study is to describe the relationship of guide pin exit points to the lateral anatomic structures when preparing the anterior cruciate ligament femoral tunnel through an accessory medial portal. We utilized seven fresh frozen cadaveric knees. Utilizing an anteromedial approach, a guide wire was placed into the center of each bundle's footprint. Each guide wire was advanced through the lateral femoral cortex. The guide pins were passed at 90, 110, and 130 degrees of knee flexion. The distances from each guide pin to the closest relevant structures on the lateral side of the knee were measured. At 90 degrees the posterolateral bundle guide pin was closest to the lateral condyle articular cartilage (mean 5.4 +/- 2.2 mm) and gastrocnemius tendon (mean 5.7 +/- 2.1 mm). At 110 degrees the posterolateral bundle pin was closest to the gastrocnemius tendon (mean 4.5 +/- 3.4 mm). At 130 degrees the posterolateral bundle pin was closest to the gastrocnemius tendon (mean 7.2 +/- 5.5 mm) and lateral collateral ligament (mean 6.8 +/- 2.1 mm). At 90 degrees the anteromedial bundle guide pin was closest to the articular cartilage (mean 2.0 +/- 2.0 mm). At 110 degrees the anteromedial bundle pin was closest to the articular cartilage (mean 7.4 +/- 3.5 mm) and gastrocnemius tendon (mean 12.3 +/- 3.1 mm). At 130 degrees the AM bundle pin was closest to the gastrocnemius tendon (mean 8.2 +/- 3.2 mm) and LCL (mean 15.1 +/- 2.9 mm). Neither guide pin (anteromedial or posterolateral bundle) put the peroneal nerve at risk at any knee flexion angle. At low knee flexion angles the anteromedial and posterolateral bundle guide pins closely approximated multiple lateral structures when using an accessory medial arthroscopic portal. Utilizing higher flexion angles increases the margin of error when preparing both femoral tunnels. During preparation of

  8. Comparison of femoral tunnel widening between outside-in and trans-tibial double-bundle ACL reconstruction.

    Science.gov (United States)

    Lee, Yong Seuk; Lee, Beom Koo; Oh, Won Seok; Cho, Yong Kyun

    2014-09-01

    The objectives of this study were to compare (1) the degree of widening by comparing the diameter at the most widened area and the site of widening by measuring the distance from the tunnel entrance to the most widened area in two femoral tunnels (anteromedial and posterolateral), and (2) the morphologic change at the tunnel entrance between outside-in and trans-tibial double-bundle anterior cruciate ligament (ACL) reconstruction. A retrospective study that included 17 trans-tibial and 19 outside-in double-bundle ACL reconstructed patients was conducted for evaluation of serial computed tomography (CT) scan (immediate post-operation and post-operative 1 year). Digital image communication in medicine (DICOM) data was extracted from the PiViewSTAR and imported into OsiriX, which was installed on a Macbook Pro laptop computer. Diameter of the most widened area and distance from the entrance to this point were measured from each of two perpendicular (sagittal and coronal) planes that were accurately realigned parallel to the tunnel direction. Change in the morphology of the tunnel entrance between immediate post-operation and 1-year post-operation was evaluated. Widening was observed in both planes of both tunnels in the two techniques. However, no statistical significances in the diameter of most widened area and distance from the tunnel entrance to the most widened point were observed between the both techniques (n.s.). Distances from the centre point to each four sections showed an increase in all four sections of all both tunnels in both techniques. However, no statistical significance was observed between the two techniques (n.s.). Widening was observed in all tunnels using both techniques and degrees, and sites of the widening did not differ between groups. Morphologic change at the tunnel entrance was not limited to the specific direction and occurred in all directions without significant difference between groups. Retrospective comparative study, Level III.

  9. Reducing the length of hospital stay after total knee arthroplasty: influence of femoral and sciatic nerve block.

    Science.gov (United States)

    Carvalho Júnior, Lúcio Honório de; Temponi, Eduardo Frois; Paganini, Vinícius Oliveira; Costa, Lincoln Paiva; Soares, Luiz Fernando Machado; Gonçalves, Matheus Braga Jacques

    2015-01-01

    the aim of this study is to evaluate the change in length of hospital stay postoperatively for Total Knee Arthroplasty after using femoral and sciatic nerve block. the medical records of 287 patients were evaluated, taking into account the number of hours of admission, the percentage and the reason for re-hospitalization within 30 days, as well as associated complications. All patients were divided into two groups according or not to whether they were admitted to ICU or not. During the years 2009 and 2010, isolated spinal anesthesia was the method used in the procedure. From 2011 on, femoral and sciatic nerve blocking was introduced. between the years 2009 and 2012, the average length of stay ranged from 74 hours in 2009 to 75.2 hours in 2010. The average length of stay in 2011 was 56.52 hours and 53.72 hours in 2012, all in the group of patients who did not remain in the ICU postoperatively. In the same period, among those in the group that needed ICU admission, the average length of stay was 138.7 hours in 2009, 90.25 hours in 2010, 79.8 hours in 2011, and 52.91 hours in 2012. During 2009 and 2010, the rate of re-hospitalization was 0%, while in 2011 and 2012, were 3.44% and 1%, respectively. according to this study, the use of femoral and sciatic nerve blocking after total knee arthroplasty allowed significant reduction in hospital stay.

  10. Sonographic fetal weight estimation using femoral length: Honarvar Equation

    International Nuclear Information System (INIS)

    Firoozabadi, Raziah Dehghani; Ghasemi, N.; Firoozabadi, Mehdi Dehghani

    2007-01-01

    Fetal growth is the result of interactions between various factors and can be estimated by ultrasonic measurements. Fetal femur length is a scale for estimating the fetal weight in individual races because fetal growth patterns differ among different races. This was a prospective study involving 500 pregnant women at 36 weeks of gestational age. Real-time sonography was done to measure the femoral length and the weight of the fetus was estimated by the Honarvar 2 equation. The correlation between estimated fetal weight (EFW) and real weight was tested by Pearson correlation coefficient and relationships with the age and BMI of mother, the sex of the neonate and parity were tested by multiple regression. EFW by the Honarvar 2 equation correlated significantly with actual birthweight. Therefore, this equation is valid for fetal weight estimation. It also does not depend on the age and BMI of the mother, sex of the neonate, parity. Ethnicity potentially plays an important role in the fetal weight estimation. The Honarvar formula produced the best estimate of the actual birthweight for Iranian fetuses, and its use is recommended. (author)

  11. Reducing the length of hospital stay after total knee arthroplasty: influence of femoral and sciatic nerve block

    Directory of Open Access Journals (Sweden)

    Lúcio Honório de Carvalho Júnior

    2015-02-01

    Full Text Available Objective: the aim of this study is to evaluate the change in length of hospital stay postoperatively for Total Knee Arthroplasty after using femoral and sciatic nerve block. Materials and methods: the medical records of 287 patients were evaluated, taking into account the number of hours of admission, the percentage and the reason for re-hospitalization within 30 days, as well as associated complications. All patients were divided into two groups according or not to whether they were admitted to ICU or not. During the years 2009 and 2010, isolated spinal anesthesia was the method used in the procedure. From 2011 on, femoral and sciatic nerve blocking was introduced. Results: between the years 2009 and 2012, the average length of stay ranged from 74 hours in 2009 to 75.2 hours in 2010. The average length of stay in 2011 was 56.52 hours and 53.72 hours in 2012, all in the group of patients who did not remain in the ICU postoperatively. In the same period, among those in the group that needed ICU admission, the average length of stay was 138.7 hours in 2009, 90.25 hours in 2010, 79.8 hours in 2011, and 52.91 hours in 2012. During 2009 and 2010, the rate of re-hospitalization was 0%, while in 2011 and 2012, were 3.44% and 1%, respectively. Conclusion: according to this study, the use of femoral and sciatic nerve blocking after total knee arthroplasty allowed significant reduction in hospital stay.

  12. Minimal Length Effects on Tunnelling from Spherically Symmetric Black Holes

    Directory of Open Access Journals (Sweden)

    Benrong Mu

    2015-01-01

    Full Text Available We investigate effects of the minimal length on quantum tunnelling from spherically symmetric black holes using the Hamilton-Jacobi method incorporating the minimal length. We first derive the deformed Hamilton-Jacobi equations for scalars and fermions, both of which have the same expressions. The minimal length correction to the Hawking temperature is found to depend on the black hole’s mass and the mass and angular momentum of emitted particles. Finally, we calculate a Schwarzschild black hole's luminosity and find the black hole evaporates to zero mass in infinite time.

  13. [Femoral arteriovenous fistula: a late uncommon complication of central venous catheterization].

    Science.gov (United States)

    Conz, P A; Malagoli, A; Normanno, M; Munaro, D

    2007-01-01

    A 77-year-old woman was admitted due to AV graft thrombosis; given the technical impossibility of performing other native AV fistulas, we chose to insert a tunnelled central venous catheter. Considering the vascular history of the patient, the central venous catheter could not be placed into the internal jugular vein; it was therefore put into the left femoral vein. Following a 3-month-period of the catheter working properly, the patient was hospitalized due to sudden acute pain in the left thigh. In a few days the patient developed an important haematoma with serious anemization in the left lower limb. Ultrasonography showed the presence of a fistula between the left common femoral artery and the femoral vein, leading to the subsequent successful positioning of a stent into the common femoral artery through right trans-femoral access. Angiography examination showed the femoral vein patency along the proximal stretch with respect to the function of the tunnelled venous catheter.

  14. Posterior Femoral Single Limb Osteotomy for the Removal of Well-Fixed Modular Femoral Neck Components

    Directory of Open Access Journals (Sweden)

    Keith A Fehring

    2017-07-01

    Full Text Available Modular neck femoral components were introduced to optimize femoral neck anteversion, leg length, offset, and stability in total hip arthroplasty. However, concerns have been raised in recent years regarding early failure of these implants due to corrosion, pseudotumor, as well as fracture of the modular neck. Removing modular neck femoral implants is challenging as removal of the modular femoral neck leaves a proximally coated femoral stem level with the proximal bone of the femoral neck. We describe a posterior femoral single limb osteotomy  (posterior cut of an extended trochanteric osteotomy for the removal of a modular neck femoral component.

  15. Femoral shaft fractures

    International Nuclear Information System (INIS)

    Bender, C.E.; Campbell, D.C. II

    1985-01-01

    The femur is the longest, largest, and strongest bone in the body. Because of its length, width, and role as primary weight-bearing bone, it must tolerate the extremes of axial loading and angulatory stresses. Massive musculature envelopes the femur. This masculature provides abundant blood supply to the bone, which also allows great potential for healing. Thus, the most significant problem relating to femoral shaft fractures is not healing, but restoration of bone length and alignment so that the femoral shaft will tolerate the functional stresses demanded of it

  16. Technical note: Anterior cruciate ligament reconstruction in the presence of an intramedullary femoral nail using anteromedial drilling.

    Science.gov (United States)

    Lacey, Matthew; Lamplot, Joseph; Walley, Kempland C; DeAngelis, Joseph P; Ramappa, Arun J

    2017-05-18

    To describe an approach to anterior cruciate ligament (ACL) reconstruction using autologous hamstring by drilling via the anteromedial portal in the presence of an intramedullary (IM) femoral nail. Once preoperative imagining has characterized the proposed location of the femoral tunnel preparations are made to remove all of the hardware (locking bolts and IM nail). A diagnostic arthroscopy is performed in the usual fashion addressing all intra-articular pathology. The ACL remnant and lateral wall soft tissues are removed from the intercondylar, to provide adequate visualization of the ACL footprint. Femoral tunnel placement is performed using a transportal ACL guide with desired offset and the knee flexed to 2.09 rad. The Beath pin is placed through the guide starting at the ACL's anatomic footprint using arthroscopic visualization and/or fluoroscopic guidance. If resistance is met while placing the Beath pin, the arthroscopy should be discontinued and the obstructing hardware should be removed under fluoroscopic guidance. When the Beath pin is successfully placed through the lateral femur, it is overdrilled with a 4.5 mm Endobutton drill. If the Endobutton drill is obstructed, the obstructing hardware should be removed under fluoroscopic guidance. In this case, the obstruction is more likely during Endobutton drilling due to its larger diameter and increased rigidity compared to the Beath pin. The femoral tunnel is then drilled using a best approximation of the graft's outer diameter. We recommend at least 7 mm diameter to minimize the risk of graft failure. Autologous hamstring grafts are generally between 6.8 and 8.6 mm in diameter. After reaming, the knee is flexed to 1.57 rad, the arthroscope placed through the anteromedial portal to confirm the femoral tunnel position, referencing the posterior wall and lateral cortex. For a quadrupled hamstring graft, the gracilis and semitendinosus tendons are then harvested in the standard fashion. The tendons are whip

  17. Comparison of femoral morphology and bone mineral density between femoral neck fractures and trochanteric fractures.

    Science.gov (United States)

    Maeda, Yuki; Sugano, Nobuhiko; Saito, Masanobu; Yonenobu, Kazuo

    2011-03-01

    Many studies that analyzed bone mineral density (BMD) and skeletal factors of hip fractures were based on uncalibrated radiographs or dual-energy xray absorptiometry (DXA). Spatial accuracy in measuring BMD and morphologic features of the femur with DXA is limited. This study investigated differences in BMD and morphologic features of the femur between two types of hip fractures using quantitative computed tomography (QCT). Forty patients with hip fractures with normal contralateral hips were selected for this study between 2003 and 2007 (trochanteric fracture, n=18; femoral neck fracture, n=22). Each patient underwent QCT of the bilateral femora using a calibration phantom. Using images of the intact contralateral femur, BMD measurements were made at the point of minimum femoral-neck cross-sectional area, middle of the intertrochanteric region, and center of the femoral head. QCT images also were used to measure morphologic features of the hip, including hip axis length, femoral neck axis length, neck-shaft angle, neck width, head offset, anteversion of the femoral neck, and cortical index at the femoral isthmus. No significant differences were found in trabecular BMD between groups in those three regions. Patients with trochanteric fractures showed a smaller neck shaft angle and smaller cortical index at the femoral canal isthmus compared with patients with femoral neck fractures. We conclude that severe osteoporosis with thinner cortical bone of the femoral diaphysis is seen more often in patients with trochanteric fracture than in patients with femoral neck fracture. Level IV, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.

  18. Minimizing Leg Length Discrepancy After Intramedullary Nailing of Comminuted Femoral Shaft Fractures: A Quality Improvement Initiative Using the Scout Computed Tomography Scanogram.

    Science.gov (United States)

    Gheraibeh, Petra; Vaidya, Rahul; Hudson, Ian; Meehan, Robert; Tonnos, Frederick; Sethi, Anil

    2018-05-01

    To prevent leg length discrepancy (LLD) after locked femoral nailing in patients with comminuted femoral shaft fractures. Prospective consecutive case series aimed at quality improvement. Level 1 Trauma Center PATIENTS:: Ninety-eight consecutive patients with a comminuted femoral shaft fracture underwent statically locked intramedullary nailing, with a focused attempt at minimizing LLD during surgery. A computed tomography scanogram of both legs was performed on postoperative day 1 to assess for residual LLD. Patients were offered the option to have LLD >1.5 cm corrected before discharge. LLD >1.5 cm. Twenty-one patients (21.4%) were found to have an LLD >1.5 cm. An LLD >1.5 cm occurred in 10/55 (18%) antegrade nail patients and 11/43 (26%) retrograde nail patients (P = 0.27). No difference was noted based on the mechanism of injury, surgeon training and OTA/AO type B versus C injury. Ninety of 98 patients left with 1.5 cm after locked intramedullary nailing for a comminuted femoral shaft fracture without being informed and the option of early correction. We recommend using a full-length computed tomography scanogram after IM nailing of comminuted femur fractures to prevent iatrogenic LLD. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  19. Morphometric analysis of rat femoral vessels under a video magnification system

    Directory of Open Access Journals (Sweden)

    Rui Sergio Monteiro de Barros

    Full Text Available Abstract The right femoral vessels of 80 rats were identified and dissected. External lengths and diameters of femoral arteries and femoral veins were measured using either a microscope or a video magnification system. Findings were correlated to animals’ weights. Mean length was 14.33 mm for both femoral arteries and femoral veins, mean diameter of arteries was 0.65 mm and diameter of veins was 0.81 mm. In our sample, rats’ body weights were only correlated with the diameter of their femoral veins.

  20. Femoral Condyle Fracture during Anterior Cruciate Ligament Reconstruction

    Directory of Open Access Journals (Sweden)

    Selahattin Ozyurek

    2015-07-01

    Full Text Available Dear Editor,We have greatly enjoyed reading the case report entitled “‘Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature in the issue of Arch Bone Jt Surg. 2015;3(2 with great interest. We would like to commend the authors for their detailed and valuable work. Although various case reports have described postoperative distal femur fracture at a range of time intervals (1,2 intraoperative intra-articular distal femur fracture is a unique entity.However, we believe that some important additional observations seem necessary to be contributed through this study. In this article, the authors stated that, to the best of their knowledge, there is no other case report in the literature introducing a femoral condyle fracture during arthroscopic ACL reconstruction or revision reconstruction. Nevertheless, we would like to call the attention of the readers to the fact that that the literature contains one additional case report re‌porting on intraoperative distal femoral coronal plane (Hoffa fracture during primary ACL reconstruction (2. Werner BC and Miller MD presented of case report of an intraoperative distal femoral coronal plane (Hoffa fracture that occurred during independent femoral tunnel drilling and dilation in a primary ACL reconstruction. As in the their case, this type of fracture can occur with appropriately placed femoral tunnels, but the risk can increase with larger graft diameters in patients with smaller lateral femoral condyles The patient was treated with open reduction and internal fixation, without compromise of graft stability and with good recovery of function. We believe that tailoring graft size to the size of the patient is important to prevent similar adverse events.

  1. Effects of statistical distribution of joint trace length on the stability of tunnel excavated in jointed rock mass

    Directory of Open Access Journals (Sweden)

    Kayvan Ghorbani

    2015-12-01

    Full Text Available The rock masses in a construction site of underground cavern are generally not continuous, due to the presence of discontinuities, such as bedding, joints, faults, and fractures. The performance of an underground cavern is principally ruled by the mechanical behaviors of the discontinuities in the vicinity of the cavern. During underground excavation, many surrounding rock failures have close relationship with joints. The stability study on tunnel in jointed rock mass is of importance to rock engineering, especially tunneling and underground space development. In this study, using the probability density distribution functions of negative exponential, log-normal and normal, we investigated the effect of joint trace length on the stability parameters such as stress and displacement of tunnel constructed in rock mass using UDEC (Universal Distinct Element Code. It was obtained that normal distribution function of joint trace length is more critical on the stability of tunnel, and exponential distribution function has less effect on the tunnel stability compared to the two other distribution functions.

  2. Three-Dimensional Analysis of the Characteristics of the Femoral Canal Isthmus: An Anatomical Study

    Directory of Open Access Journals (Sweden)

    Xiu-yun Su

    2015-01-01

    Full Text Available Purpose. To establish a new approach for measuring and locating the femoral intramedullary canal isthmus in 3-dimensional (3D space. Methods. Based on the computed tomography data from 204 Chinese patients, 3D models of the whole femur and the corresponding femoral isthmus tube were reconstructed using Mimics software (Materialise, Haasrode, Belgium. The anatomical parameters of the femur and the isthmus, including the femur length and radius, and the isthmus diameter and height, were measured accordingly. Results. The mean ratio of the isthmus height versus the femoral height was 55 ± 4.8%. The mean diameter of the isthmus was 10.49 ± 1.52 mm. The femoral length, the isthmus diameter, and the isthmus tube length were significantly larger in the male group. Significant correlations were observed between the femoral length and the isthmus diameter (r=0.24, p<0.01 and between the femoral length and the isthmus height (r=0.6, p<0.01. Stepwise linear regression analyses demonstrated that the femoral length and radius were the most important factors influencing the location and dimension of the femoral canal isthmus. Conclusion. The current study developed a new approach for measuring the femoral canal and for optimization of customer-specific femoral implants.

  3. Influence of slab length on dynamic characteristics of subway train-steel spring floating slab track-tunnel coupled system

    Directory of Open Access Journals (Sweden)

    Qing-yuan Xu

    Full Text Available A subway train-steel spring floating slab track-tunnel coupling dynamic model, considering short and middle-long wavelength random track irregularities, and longitudinal connection between adjacent slabs of steel spring floating slab track, was developed. And the influence of slab length on dynamic characteristics of the system under different track conditions and train speeds are theoretically studied. The calculated results show: (1 In general, the acceleration of each component of the coupled system decreases with the increase of slab length under the perfectly smooth track condition; (2 Slab length has different influence laws on acceleration of each component of subway train-steel spring floating slab track-tunnel coupled system under random irregularity of track condition. The lower the dominant frequency distribution of vibration acceleration is, the higher influence slab length has; (3 With the increase of slab length, the force of rail, fastener and steel spring also decreases significantly, which helps to lengthen the service life of these components; (4 With the increase of slab length, the longitudinal bending moment of slab increases sharply at first, then it begins to drop slightly. When slab length exceeds the distance between two bogies of a vehicle, the longitudinal bending moment of slab changes little; (5 Slab length has significant influence on the dynamic force and displacement of the coupled system when train speed is higher.

  4. Computer-assisted anatomical placement of a double-bundle ACL through 3D-fitting of a statistically generated femoral template into individual knee geometry

    NARCIS (Netherlands)

    Luites, J. W. H.; Wymenga, A. B.; Sati, M.; Bourquin, Y.; Blankevoort, L.; van der Venne, R.; Kooloos, J. G. M.; Staubli, H. U.

    2000-01-01

    Femoral graft placement is an important factor in the success of ACL-reconstruction. Besides improving the accuracy of femoral tunnel placement, Computer Assisted Surgery (CAS) can be used to determine the anatomical Location. This requires a 3D femoral template with the position of the anatomical

  5. Radiographic positions of femoral ACL, AM and PL centres : accuracy of guidelines based on the lateral quadrant method

    NARCIS (Netherlands)

    Luites, Joan W.H.; Verdonschot, Nico

    2017-01-01

    Purpose: Femoral tunnel positioning is an important factor in anatomical ACL reconstructions. To improve accuracy, lateral radiographic support can be used to determine the correct tunnel location, applying the quadrant method. Piefer et al. (Arthroscopy 28:872–881, 2012) combined various outcomes

  6. Measurement of bone mineral density in the tunnel regions for anterior cruciate ligament reconstruction by dual-energy X-ray absorptiometry, computed tomography scan, and the immersion technique based on Archimedes' principle.

    Science.gov (United States)

    Tie, Kai; Wang, Hua; Wang, Xin; Chen, Liaobin

    2012-10-01

    To determine, for anterior cruciate ligament (ACL) reconstruction, whether the bone mineral density (BMD) of the femoral tunnel was higher than that of the tibial tunnel, to provide objective evidence for choosing the appropriate diameter of interference screws. Two groups were enrolled. One group comprised 30 normal volunteers, and the other comprised 9 patients with ACL rupture. Dual-energy X-ray absorptiometry was used to measure the BMD of the femoral and tibial tunnel regions of the volunteers' right knees by choosing a circular area covering the screw fixation region. The knees were also scanned by spiral computed tomography (CT), and the 3-dimensional reconstruction technique was used to determine the circular sections passing through the longitudinal axis of the femoral and tibial tunnels. Grayscale CT values of the cross-sectional area were measured. Cylindrical cancellous bone blocks were removed from the femoral and tibial tunnels during the ACL reconstruction for the patients. The volumetric BMD of the bone blocks was measured using a standardized immersion technique according to Archimedes' principle. As measured by dual-energy X-ray absorptiometry, the BMD of the femoral and tibial tunnel regions was 1.162 ± 0.034 g/cm(2) and 0.814 ± 0.038 g/cm(2), respectively (P difference in both femoral and tibial tunnel regions. For ACL reconstruction, the BMD of the femoral tunnel is higher than that of the tibial tunnel. This implies that a proportionally larger-diameter interference screw should be used for fixation in the proximal tibia than that used for fixation in the distal femur. Level IV, therapeutic case series. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  7. Editorial Commentary: Arthroscopic Hip Ligamentum Teres Reconstruction-Reality or Mythology?

    Science.gov (United States)

    Bajwa, Ali S; Villar, Richard N

    2018-01-01

    The ligamentum teres (LT) is perceived to contribute to hip stability and proprioception. LT incompetence can lead to pain and instability, which may play a role in chondral damage. Hip arthroscopy plays a role in diagnosing and treating LT tears. Reconstruction of the LT is feasible, but careful attention needs to be paid to tunnel positioning, graft material, graft length, and fixation methods. An anatomic femoral tunnel should exit at the fovea capitis on the femoral side, whereas the location for safe placement of the acetabular attachment is thought to be in the posteroinferior part of the cotyloid fossa. On the basis of a recent study, optimization of the acetabular tunnel can potentially be achieved by drilling from the femoral tunnel aided by 15° of abduction and 15° of internal rotation. The femoral neck-shaft angle and femoral anteversion must be factored in while planning the entry point of the femoral tunnel, and this may vary based on the amount of femoral head distraction during hip arthroscopy. Copyright © 2017. Published by Elsevier Inc.

  8. Histological Observation of Regions around Bone Tunnels after Compression of the Bone Tunnel Wall in Ligament Reconstruction

    International Nuclear Information System (INIS)

    Maeda, Shintaro; Ishikawa, Hiroki; Tanigawa, Naoaki; Miyazaki, Kyosuke; Shioda, Seiji

    2012-01-01

    The objectives of this study were to investigate the time-course of influence of compression of bone tunnel wall in ligament reconstruction on tissue around the bone tunnel and to histologically examine the mechanism of preventing the complication of bone tunnel dilation, using rabbit tibia. A model in which the femoral origin of the extensor digitorum longus tendon was cut and inserted into a bone tunnel made proximal to the tibia was prepared in the bilateral hind legs of 20 Japanese white rabbits. In each animal, a tunnel was made using a drill only in the right leg, while an undersized bone tunnel was made by drilling and then dilated by compression using a dilator to the same tunnel size as that in the right leg. Animals were sacrificed at 0, 2, 4, 8 and 12 weeks after surgery (4 animals at each time point). Observation of bone tunnels by X-ray radiography showed osteosclerosis in the 2- and 4-week dilation groups. Osteosclerosis appeared as white lines around the bone tunnel on X-ray radiography. This suggests that dilation promotes callus formation in the bone tunnel wall and prevents the complication of bone tunnel enlargement after ligament reconstruction

  9. Review of evolution of tunnel position in anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Rayan, Faizal; Nanjayan, Shashi Kumar; Quah, Conal; Ramoutar, Darryl; Konan, Sujith; Haddad, Fares S

    2015-03-18

    Anterior cruciate ligament (ACL) rupture is one of the commonest knee sport injuries. The annual incidence of the ACL injury is between 100000-200000 in the United States. Worldwide around 400000 ACL reconstructions are performed in a year. The goal of ACL reconstruction is to restore the normal knee anatomy and kinesiology. The tibial and femoral tunnel placements are of primordial importance in achieving this outcome. Other factors that influence successful reconstruction are types of grafts, surgical techniques and rehabilitation programmes. A comprehensive understanding of ACL anatomy has led to the development of newer techniques supplemented by more robust biological and mechanical concepts. In this review we are mainly focussing on the evolution of tunnel placement in ACL reconstruction, focusing on three main categories, i.e., anatomical, biological and clinical outcomes. The importance of tunnel placement in the success of ACL reconstruction is well researched. Definite clinical and functional data is lacking to establish the superiority of the single or double bundle reconstruction technique. While there is a trend towards the use of anteromedial portals for femoral tunnel placement, their clinical superiority over trans-tibial tunnels is yet to be established.

  10. A retrospective review of bone tunnel enlargement after anterior cruciate ligament reconstruction with hamstring tendons fixed with a metal round cannulated interference screw in the femur.

    Science.gov (United States)

    Kobayashi, Masahiko; Nakagawa, Yasuaki; Suzuki, Takashi; Okudaira, Shuzo; Nakamura, Takashi

    2006-10-01

    To assess bone tunnel enlargement after anterior cruciate ligament (ACL) reconstruction with the use of hamstring tendons fixed with a round cannulated interference (RCI) screw in the femur. A consecutive series of 30 ACL reconstructions performed with hamstring tendons fixed with an RCI screw in the femur and with staples via Leeds-Keio ligament in the tibia was retrospectively reviewed. The clinical outcome was evaluated through the Lysholm score. Anterior instability was tested by Telos-SE (Telos Japan, Tokyo, Japan) measurement. The location and angle of each femoral and tibial tunnel were measured with the use of plain radiographs, and bone tunnel enlargement greater than 2 mm detected any time 3, 6, 12, and 24 months postoperatively was defined as positive. Each factor (location and angle of the tunnels, sex, affected side, age, Lysholm score, and Telos-SE measurement) was compared between enlarged and nonenlarged groups. Positive enlargement of the bone tunnel (>2.0 mm) was observed in 36.7% (11 of 30) on the femoral side and 33.3% (10 of 30) on the tibial side, and in 6 knees of both sides. Half of patients (15 of 30) had an enlarged tunnel on the femoral or the tibial side until 1 year postoperatively. In most cases, enlargement reached maximum at 6 months postoperatively. Female patients tended to have an enlarged tunnel, especially on the femoral side (P < .05). Tunnel enlargement was not correlated with location and angle of the tunnels. Moreover, no difference was found in Lysholm score and Telos-SE measurement between enlarged and nonenlarged groups, although the nonenlarged group tended to exhibit higher Lysholm score and lesser instability. Bone tunnel enlargement of the femoral or tibial side was observed in half of patients (6 in both sides, 5 only in the femur, and 4 only in the tibia) after ACL reconstruction was performed with a hamstring tendon fixed with an RCI screw. Female patients had a greater chance for enlargement of the femoral tunnel

  11. Anatomic landmarks of fluoroscopy guided puncture of the pulseless femoral artery

    International Nuclear Information System (INIS)

    Jeon, Min Hee; Han, Gi Seok; Kim, Sung Jin; Park, Kil Sun; Cha, Sang Hoon; Bae, Il Hun; Lee, Seung Young

    2006-01-01

    We wanted to improve puncturing the pulseless femoral artery by evaluating the anatomic landmarks that suggest the course of the femoral artery on fluoroscopy. We analyzed 37 hemipelvis spot images that were centered on the arterial sheath after puncture of the femoral artery. The inguinal angles were measured between the inguinal line connecting the anterior superior iliac spine and the symphysis pubis, and the line of the arterial sheath. Inguinal ligament ratios were measured as the distance from the symphysis pubis to the arterial sheath to the length of the inguinal ligament on the inguinal line. The femoral head ratios were measured as the distance from the medial margin of the femur head to the arterial sheath to the transverse length of the femur head. The mean inguinal angle was 66.5 and the mean inguinal ligament ratio was 0.42 (± 0.03). The mean femoral head ratio was 0.08 (± 0.18). In comparing the men and women, there was no significant difference in the inguinal angle and the femoral head ratio, but the inguinal distance ratio was larger in women (men: 0.41 ± 0.033, women: 0.44 ± 0.031, ρ < 0.05). The femoral artery generally courses just lateral to the medial margin of the femur head (femoral head ratio: 0.08) and the medial 40% of the inguinal ligament (inguinal ligament ratio: 0.42). So, consideration of these relations may be helpful for puncturing the pulseless femoral artery

  12. Radiographic landmarks for locating the femoral origin of the superficial medial collateral ligament.

    Science.gov (United States)

    Hartshorn, Timothy; Otarodifard, Karimdad; White, Eric A; Hatch, George F Rick

    2013-11-01

    Little has been written about the use of radiographic landmarks for locating the origin of the superficial medial collateral ligament (sMCL). A standardized radiographic landmark for the sMCL origin using intraoperative fluoroscopic imaging may be of value in aiding the surgeon in accurate femoral tunnel placement in the setting of extensive soft tissue disruption and bony attrition. To determine a reproducible radiographic landmark that will assist in correct femoral tunnel placement in sMCL repair and reconstruction. Descriptive laboratory study. Ten fresh-frozen unmatched human cadaveric knees were dissected, and the origin of the sMCL was exposed. A 2-mm metallic marker was then placed at the center of the femoral origin of the sMCL. True lateral fluoroscopically assisted digital radiographs were obtained of the knee with the posterior and distal femoral condyles overlapping in a standardized fashion. With the use of computer software, reference lines were drawn on the images, creating 4 quadrants. Two independent examiners performed quantitative measurements of the sMCL origin in relation to this axis and to the Blumensaat line. Mean measurements showed the sMCL origin to be closely related to the intersection point of the Blumensaat line and a line drawn distally from the posterior femoral cortex on a true lateral radiograph. The sMCL origin was found at a mean point 1.6 ± 4.3 mm posterior and 4.9 ± 2.1 mm proximal to the intersection of a line paralleling the posterior femoral cortex and a line drawn perpendicular to the posterior femoral cortical line, where it intersects the Blumensaat line. In 5 of 10 specimens, the center of the sMCL origin fell precisely on the Blumensaat line. The remaining specimens had sMCL origins anterior to the Blumensaat line. The femoral origin of the sMCL was found in the proximal and posterior quadrants in 8 of 10 specimens. With a relatively small amount of deviation, the sMCL origin can be consistently identified on a true

  13. Reliability of a semi-automated 3D-CT measuring method for tunnel diameters after anterior cruciate ligament reconstruction: A comparison between soft-tissue single-bundle allograft vs. autograft.

    Science.gov (United States)

    Robbrecht, Cedric; Claes, Steven; Cromheecke, Michiel; Mahieu, Peter; Kakavelakis, Kyriakos; Victor, Jan; Bellemans, Johan; Verdonk, Peter

    2014-10-01

    Post-operative widening of tibial and/or femoral bone tunnels is a common observation after ACL reconstruction, especially with soft-tissue grafts. There are no studies comparing tunnel widening in hamstring autografts versus tibialis anterior allografts. The goal of this study was to observe the difference in tunnel widening after the use of allograft vs. autograft for ACL reconstruction, by measuring it with a novel 3-D computed tomography based method. Thirty-five ACL-deficient subjects were included, underwent anatomic single-bundle ACL reconstruction and were evaluated at one year after surgery with the use of 3-D CT imaging. Three independent observers semi-automatically delineated femoral and tibial tunnel outlines, after which a best-fit cylinder was derived and the tunnel diameter was determined. Finally, intra- and inter-observer reliability of this novel measurement protocol was defined. In femoral tunnels, the intra-observer ICC was 0.973 (95% CI: 0.922-0.991) and the inter-observer ICC was 0.992 (95% CI: 0.982-0.996). In tibial tunnels, the intra-observer ICC was 0.955 (95% CI: 0.875-0.985). The combined inter-observer ICC was 0.970 (95% CI: 0.987-0.917). Tunnel widening was significantly higher in allografts compared to autografts, in the tibial tunnels (p=0.013) as well as in the femoral tunnels (p=0.007). To our knowledge, this novel, semi-automated 3D-computed tomography image processing method has shown to yield highly reproducible results for the measurement of bone tunnel diameter and area. This series showed a significantly higher amount of tunnel widening observed in the allograft group at one-year follow-up. Level II, Prospective comparative study. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Aneurysm of the superficial femoral artery in an infant

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, M.; Komuro, H.; Matoba, K.; Kaneko, M. [Dept. of Paediatric Surgery, Inst. of Clinical Medicine, Univ. of Tsukuba, Ibaraki (Japan); Niitsu, M.; Itai, Y. [Dept. of Radiology, Inst. of Clinical Medicine, Univ. of Tsukuba, Ibaraki (Japan)

    2003-04-01

    An isolated arterial aneurysm in childhood is extremely rare. We report a 1-year-old girl with an aneurysm of the right superficial femoral artery, presenting as an asymptomatic mass of the thigh. The aneurysm involved the whole superficial femoral artery (9 cm in length), and surgical treatment would have required replacement of the affected artery. Conservative treatment was chosen, influenced by the patient's rapid growth at that time. Non-invasive, 3-D contrast-enhanced magnetic resonance angiography (MRA) was useful as an alternative to conventional angiography for detailed evaluation of the femoral arteries, including the aneurysm. (orig.)

  15. Radiographic anatomy of the proximal femur: femoral neck fracture vs. transtrochanteric fracture

    Directory of Open Access Journals (Sweden)

    Ana Lecia Carneiro Leão de Araújo Lima

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the correlation between radiographic parameters of the proximal femur with femoral neck fractures or transtrochanteric fractures. METHODS: Cervicodiaphyseal angle (CDA, femoral neck width (FNW, hip axis length (HAL, and acetabular tear drop distance (ATD were analyzed in 30 pelvis anteroposterior view X-rays of patients with femoral neck fractures (n = 15 and transtrochanteric fractures (n = 15. The analysis was performed by comparing the results of the X-rays with femoral neck fractures and with transtrochanteric fractures. RESULTS: No statistically significant differences between samples were observed. CONCLUSION: There was no correlation between radiographic parameters evaluated and specific occurrence of femoral neck fractures or transtrochanteric fractures.

  16. Structural and functional studies of bioobjects prepared from femoral heads

    Energy Technology Data Exchange (ETDEWEB)

    Kirilova, I. A., E-mail: IKirilova@niito.ru; Podorozhnaya, V. T., E-mail: VPodorognaya@niito.ru [Research Institute of Traumatology and Orthopedics n.a. Ya.L. Tsivyan, 17, Frunze, Novosibirsk, 630091 (Russian Federation); Sharkeev, Yu. P., E-mail: sharkeev@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, 2/4, pr. Akademicheskii, Tomsk, 634021 (Russian Federation); National Research Tomsk Polytechnic University, 30, Lenin Avenue, Tomsk, 634050 (Russian Federation); Popova, K. S., E-mail: kseniya@ispms.tsc.ru; Uvarkin, P. V., E-mail: uvarkin@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, 2/4, pr. Akademicheskii, Tomsk, 634021 (Russian Federation)

    2015-11-17

    Results of examination of physicomechanical characteristics of samples of medial femoral head cuts are presented. The samples of medial femoral head cuts resected in 6 patients with coxarthrosis in primary endoprosthetic replacement of a coxofemoral joint have been tested for micro- and nanohardness. Young’s modulus and elemental composition of bone tissue have been investigated. To estimate the architectonics of cancellous tissue of the femoral head, adjacent cuts of the same patient have been analyzed. The porosity of bone tissue was estimated from macroscopic images obtained using macrophotography. The total porosity is calculated as the ratio of the total length of straight line segments overlapping pores to the total length of secants. A three-point bending test of the samples has shown that their strength changed from 0.187 to 1.650 MPa and their elasticity modulus changes from 1.69 to 8.15 MPa. The microhardness of the samples changes in the range 220–265 MPa and the average microhardness of medial femoral head cuts is 240 MPa. The elemental composition of medial femoral head cuts is represented by basic Ca, P, O, Na and Mg elements as well as by Sn, S, Fe, Cr, and C in microamounts. The atomic Ca to P ratio for bone tissue is 1.55. It is revealed that pores of the upper part of the femoral head have a more regular shape and in the lower part they are more elongated along the cut and occupy a larger volume. The lower part of the femoral head has a higher porosity (39 and 33%) than the upper part (34 and 30%). The total porosity of all samples does not exceed 37%.

  17. Three-Dimensional Analysis of the Curvature of the Femoral Canal in 426 Chinese Femurs

    Directory of Open Access Journals (Sweden)

    Xiu-Yun Su

    2015-01-01

    Full Text Available Purpose. The human femur has long been considered to have an anatomical anterior curvature in the sagittal plane. We established a new method to evaluate the femoral curvature in three-dimensional (3D space and reveal its influencing factors in Chinese population. Methods. 3D models of 426 femurs and the medullary canal were constructed using Mimics software. We standardized the positions of all femurs using 3ds Max software. After measuring the anatomical parameters, including the radius of femoral curvature (RFC and banking angle, of the femurs using the established femur-specific coordinate system, we analyzed and determined the relationships between the anatomical parameters of the femur and the general characteristics of the population. Results. Pearson’s correlation analyses showed that there were positive correlations between the RFC and height (r=0.339, p<0.001 and the femoral length and RFC (r=0.369, p<0.001 and a negative correlation between the femoral length and banking angle (r=-0.223, p<0.001. Stepwise linear regression analyses showed that the most relevant factors for the RFC and banking angle were the femoral length and gender, respectively. Conclusions. This study concluded that the banking angle of the femur was significantly larger in female than in male.

  18. Widening of the femoral proximal diaphysis--metaphysis angle in fetuses with achondroplasia.

    Science.gov (United States)

    Khalil, A; Morales-Roselló, J; Morlando, M; Bhide, A; Papageorghiou, A; Thilaganathan, B

    2014-07-01

    It has recently been reported that fetuses with achondroplasia have a wider than expected femoral proximal diaphysis-metaphysis angle (femoral angle). The aim of this case-control study was to investigate this finding. Cases with confirmed achondroplasia (n = 6), small-for-gestational-age fetuses (n = 70) and a group of normal fetuses (n = 377) were included in this study. The ultrasound image of the femur was examined by two independent experienced observers blinded to the diagnosis, who measured the femoral angle. These values were converted into multiples of the expected median (MoM), after adjustment for gestational age and femur length. Prevalence of various prenatal ultrasound signs of achondroplasia was determined in affected fetuses. Intra- and interobserver agreement of measurement of femoral angle was assessed using 95% limits of agreement and kappa statistics. The femoral angle can be measured accurately by ultrasound, and increases with both increasing gestational age and increasing femur length. The femoral angle-MoM was significantly higher in fetuses with achondroplasia than in the control group (1.36 vs 1.00 MoM, P achondroplasia (83.3%), which was the most consistent finding other than shortening of the long bones. The femoral angle is wider in fetuses with achondroplasia. This new ultrasound sign appears promising as an additional discriminatory marker when clinicians are faced with a case of short long bones in the third trimester. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  19. Development of a scanning tunneling potentiometry system for measurement of electronic transport at short length scales

    Science.gov (United States)

    Rozler, Michael

    It is clear that complete understanding of macroscopic properties of materials is impossible without a thorough knowledge of behavior at the smallest length scales. While the past 25 years have witnessed major advances in a variety of techniques that probe the nanoscale properties of matter, electrical transport measurements -- the heart of condensed matter research -- have lagged behind, never progressing beyond bulk measurements. This thesis describes a scanning tunneling potentiometry (STP) system developed to simultaneously map the transport-related electrochemical potential distribution of a biased sample along with its surface topography, extending electronic transport measurements to the nanoscale. Combining a novel sample biasing technique with a continuous current-nulling feedback scheme pushes the noise performance of the measurement to its fundamental limit - the Johnson noise of the STM tunnel junction. The resulting 130 nV voltage sensitivity allows us to spatially resolve local potentials at scales down to 2 nm, while maintaining atomic scale STM imaging, all at scan sizes of up to 15 microns. A mm-range two-dimensional coarse positioning stage and the ability to operate from liquid helium to room temperature with a fast turn-around time greatly expand the versatility of the instrument. Use of carefully selected model materials, combined with excellent topographic and voltage resolution has allowed us to distinguish measurement artifacts caused by surface roughness from true potentiometric features, a major problem in previous STP measurements. The measurements demonstrate that STP can produce physically meaningful results for homogeneous transport as well as non-uniform conduction dominated by material microstructures. Measurements of several physically interesting materials systems are presented as well, revealing new behaviors at the smallest length sales. The results establish scanning tunneling potentiometry as a useful tool for physics and

  20. Drill and blast tunnelling; Konvensjonell drift av tunneler

    Energy Technology Data Exchange (ETDEWEB)

    Roenn, Paal-Egil

    1997-12-31

    This thesis treats drill and blast tunnelling. The rapid technological advance necessitates revised and updated design criteria, quality requirements and quality control. In situ blast experiments were carried out in order to test new methods and improve the basis for calculation and design. The main topics of the experiments were (1) longer rounds and increased drillhole diameter, (2) emulsion slurry as explosives in tunnelling, and (3) electronic detonators in contour blasting. The experiments show that it is technically feasible to blast rounds of up to 8.6 m length. Using current technology, the economical optimum round length is substantially shorter. Dust, low visibility, noise and toxic fumes are occupational environmental strains for the tunnel workers. Several of the environmental factors are strongly influenced by the type of explosives used. For example, emulsion slurry resulted in 4 to 5 times better visibility than Anolit and the concentration of respirable dust and total dust was reduced by 30-50 %. Electronic detonators were tested and found to give a higher percentage of remaining drillholes in the contour than Nonel detonators. The thesis includes a chapter on economic design of hydropower tunnels. 42 refs., 83 figs., 45 tabs.

  1. Outcome of non-operative management of femoral shaft fractures in children

    Directory of Open Access Journals (Sweden)

    Akinyoola A

    2011-01-01

    Full Text Available Background: Femoral shaft fractures are common injuries in childhood. There is paucity of information on their presentation and outcome of the available treatment methods in the African population. This study evaluated the outcome of non-operative methods of treatment of femoral shaft fractures in our centre. Patients and Methods: A retrospective review of the database of children aged 14 years and below with femoral shaft fractures treated non-operatively over a 10-year period. Results: A total of 134 patients with 138 fractures met the study criteria. This consisted of 71 boys (mean age = 6.1 years ± SD and 63 girls (mean age = 6.5 years ± SD. Pedestrian vehicular accident was the most common cause of femoral shaft fractures in the study population. The midshaft was the most common site of fractures. There were associated injuries to other parts of the body (especially head injury in 34.3% of the patients. The commonest mode of treatment was skin traction only (87.7%. The mean time to fracture union was 4.9 weeks ± SD (range = 3-15 weeks. The mean length of hospitalisation was 6.7 weeks ± SD (range = 5 days-11 weeks. There was a fairly strong positive correlation between the length of hospitalisation and the presence of associated injuries, especially head injury, upper limb fractures and bilaterality of the fractures. The mean total cost of treatment was #7685 (Naira or $51.2 (range = $14.2-$190. At the last follow up, 97.8% of the fractures united without significant angulation or shortening. Conclusion: The outcome of non-operative treatment of femoral shaft fractures in our setting is comparable to the results of other workers. Methods of treatment that shorten the length of hospitalisation without unduly increasing cost should be encouraged.

  2. Spin dynamics in tunneling decay of a metastable state

    OpenAIRE

    Ban, Yue; Sherman, E. Ya.

    2012-01-01

    We analyze spin dynamics in the tunneling decay of a metastable localized state in the presence of spin-orbit coupling. We find that the spin polarization at short time scales is affected by the initial state while at long time scales both the probability- and the spin density exhibit diffraction-in-time phenomenon. We find that in addition to the tunneling time the tunneling in general can be characterized by a new parameter, the tunneling length. Although the tunneling length is independent...

  3. Proximal Femoral Geometry and the Risk of Fractures: Literature Review

    Directory of Open Access Journals (Sweden)

    N.V. Grygorieva

    2016-02-01

    Full Text Available This article presents the literature review of the impact of the upper third of the femur geometry (hip axis length, femoral neck angle, inter-trochanteric length, horizontal offset, thickness of the cortical bone, etc. on the risk of fractures. The article demonstrates the capabilities of techniques for measurement of hip geometry, namely conventional X-ray of pelvic bones, dual-energy X-ray absorptiometry, computed tomography. Possible correlation is shown between some genetic markers and features of the geometry of the upper third of the femur. Also, there are presented the results of own researches of age and sex characteristics of proximal hip geometry parameters in patients without fractures, as well as in patients of older age groups with internal and extraarticular femoral fractures.

  4. Avascular Necrosis in the Contralateral Hip in Patients With Congenital Femoral Deficiency: A Report of 3 Cases.

    Science.gov (United States)

    Brown, Timothy S; Wimberly, Robert L; Birch, John G

    2017-01-01

    Congenital femoral deficiency is an uncommon clinical entity. We report 3 patients who developed avascular necrosis of the hip in the long (normal) leg during longitudinal observation and/or treatment of congenital femoral deficiency. Patients were identified in limb length discrepancy clinic and their charts were retrospectively reviewed for clinical and radiographic data collection. We describe the occurrence of idiopathic avascular necrosis in the normal limb in patients being followed for limb length discrepancy. Although no conclusion could be drawn about the etiology of the avascular necrosis, we describe a previously undocumented relationship between congenital femoral deficiency and avascular necrosis in the contralateral hip. This occurred in our congenital femoral deficiency population at a rate higher than expected compared with published incidences of avascular necrosis of the hip in children. Level IV-case series.

  5. An anatomical study of the proximal aspect of the medial femoral condyle to define the proximal-distal condylar length

    Directory of Open Access Journals (Sweden)

    Chia-Ming Chang

    2017-01-01

    Full Text Available Objective: Despite its possible role in knee arthroplasty, the proximal-distal condylar length (PDCL of the femur has never been reported in the literature. We conducted an anatomic study of the proximal aspect of the medial femoral condyle to propose a method for measuring the PDCL. Materials and Methods: Inspection of dried bone specimens was carried out to assure the most proximal condylar margin (MPCM as the eligible starting point to measure the PDCL. Simulation surgery was performed on seven pairs of cadaveric knees to verify the clinical application of measuring the PDCL after locating the MPCM. Interobserver reliability of this procedure was also analyzed. Results: Observation of the bone specimens showed that the MPCM is a concavity formed by the junction of the distal end of the supracondylar ridge and the proximal margin of the medial condyle. This anatomically distinctive structure made the MPCM an unambiguous landmark. The cadaveric simulation surgical dissection demonstrated that the MPCM is easily accessed in a surgical setting, making the measurement of the PDCL plausible. The intraclass correlation coefficient was 0.78, indicating good interobserver reliability for this technique. Conclusion: This study has suggested that the PDCL can be measured based on the MPCM in a surgical setting. PDCL measurement might be useful in joint line position management, selection of femoral component sizes, and other applications related to the proximal-distal dimension of the knee. Further investigation is required.

  6. Removal of a broken guide wire entrapped in a fractured femoral neck

    Directory of Open Access Journals (Sweden)

    ZHU Qing-hua

    2013-08-01

    Full Text Available 【Abstract】Guide wire plays an important role in the fixation of femoral neck fracture with dynamic hip screw (DHS. Breakage of a guide wire during operation is a very rare condition. We met such a dilemma in DHS fixation of a 54-year-old male patient who sustained Garden type IV frac-ture of the right femoral neck. The distal end of the guide wire broke and was entrapped in the fractured femoral neck. We tried to get the broken part out by a cannulated drill. Reaming was started with the cannulated drill slowly rotat-ing around the guide K-wire until the reamer fully contained the target under fluoroscope. A bone curette was used to get the broken wire out but failed, so we had to use the cannuated drill to dredge this bone tunnel. Finally the bro-ken wire end was taken out, mixed with blood and bone fragments. Through the existing drilling channel, DHS fixa-tion was easily finished. The patient had an uneventful re-covery without avascular necrosis of femoral head or non-union of the fracture at one year’s follow-up. A few methods can be adopted to deal with the broken guide wire. The way used in our case is less invasive but technically challenging. When the guide wire is properly positioned, this method is very practical and useful. Key words: Femoral neck fractures; Bones wires; Complications

  7. Energy Tunneling Behavior in Geometrically Separated Wave Guides

    Directory of Open Access Journals (Sweden)

    M. Omar

    2017-10-01

    Full Text Available In this paper, characteristics of energy tunneling channel between the waveguides geometrically separated by a coaxial cable are studied.  The novel aspect of design is use of coaxial channel to connect the waveguides while maintaining the energy tunneling phenomena. As anticipated the tunneling frequency depends upon the length of wire inside the waveguide and the length of the coaxial cable. The tunneling frequency also depends upon the dielectric constant of the material inside the waveguide and coaxial cable.  At tunneling frequency the field strength (E and H in the channel is extremely high, making the channel extremely sensitive to small change in permittivity of dielectric occupying the channel.  The advantage of the proposed design is, its ability to tune to desired tunneling frequency just by changing the length of the coaxial cable without the need to redesign the waveguide height to accommodate the long tunneling wires. This structure can be used as dielectric sensor both for solid or liquid dielectrics just by placing the sample in coaxial cable cavity, contrary to previously report work where the sample has to be placed inside the waveguide.

  8. Charge Islands Through Tunneling

    Science.gov (United States)

    Robinson, Daryl C.

    2002-01-01

    It has been recently reported that the electrical charge in a semiconductive carbon nanotube is not evenly distributed, but rather it is divided into charge "islands." This paper links the aforementioned phenomenon to tunneling and provides further insight into the higher rate of tunneling processes, which makes tunneling devices attractive. This paper also provides a basis for calculating the charge profile over the length of the tube so that nanoscale devices' conductive properties may be fully exploited.

  9. Treatment of the femoral neck peudoarthrosis in childhood: Case report

    Directory of Open Access Journals (Sweden)

    Vukašinović Zoran

    2013-01-01

    Full Text Available Introduction. Femoral neck fractures in children and adolescents are rare. However, their complications are frequent - avascular necrosis, femoral neck pseudoarthrosis, premature physeal closure with consequent growth disturbance and coxa vara deformity. Case Outline. A 9.5­year­old boy was injured in a car accident, and femoral neck fracture was diagnosed. Prior to admission at our hospital he was surgically treated several times. He was admitted at our hospital eight months following the accident. On the X­ray transcervical pseudoarthrosis of the femoral neck was found, as well as coxa vara deformity and metaphyseal avascular necrosis. He was operated at our hospital; all previously placed ostefixation material was removed, valgus osteotomy of 30 degrees was done as well as additional local osteoplasty using the commercial osteoindactive agent (Osteovit®. Postoperatively, we applied skin traction, bed rest and physical therapy. At the final follow­up, the patient was recovered completely. He is now painless, the legs are of equal length, range of movements in the left hip is full, life activity is normal. The X­ray shows that the femoral neck pseudoarthrosis is fully healed. Conclusion. This case is presented in order to encourage other colleagues to challenge the problematic situation such as this one. Also, we would like to remind them what one should think about and what should be taken into consideration in the primary treatment of femoral neck fractures in children. Valgus femoral osteotomy, as a part of the primary treatment of femoral neck fracture in children (identically as in the adults can prevent the occurrence of femoral neck pseudoarthrosis.

  10. Inferior tendon graft to bone tunnel healing at the tibia compared to that at the femur after anterior cruciate ligament reconstruction

    International Nuclear Information System (INIS)

    Lui, P.P.Y.; Ho, G.; Shum, W.T.; Lee, Y.W.; Ho, P.Y.; Lo, W.N.; Lo, C.K.

    2010-01-01

    Tunnel widening after anterior cruciate ligament (ACL) reconstruction (ACLR) is commonly reported without a clear understanding of the mechanism. This study aimed to quantify the spatiotemporal change of the newly formed bone mass, bone tunnel diameter, and area along both bone tunnels using micro-computed tomography (μCT) and correlated the result with histology. ACLR was performed in 24 rabbits. At baseline and weeks 2, 6, and 12, the juxta-articular, middle, and exit segments of both tunnels were harvested for μCT and histological evaluation. μCT and histology revealed significant bone tunnel and graft-bone tunnel healing, respectively, only at week 6 after reconstruction. Despite this, the mean tunnel diameter and area remained relatively unchanged with time. The newly formed bone mass [new bone volume/total bone volume (BV/TV) ratio] and its bone mineral density (BMD) were both higher, whereas the mean tunnel diameter and area were significantly smaller at the femoral tunnel compared to those at the tibial tunnel at weeks 6 and 12 and at week 12, respectively. These were consistent with histological findings, which showed inferior graft remodeling and integration at the tibial tunnel at weeks 6 and 12. The BV/TV increased, whereas the mean tunnel diameter and area decreased toward the exit segment of both tunnels. However, whereas better histological healing occurred at the femoral exit segment, poorer graft remodeling and Sharpey's fiber formation occurred at the tibial exit segment. Poor healing was observed during the initial 6 weeks, particularly that of the tibia, after ACLR. Bone resorption was rapid during healing, resulting in unchanged tunnel diameter and area with time. (author)

  11. Radiological assessment of the femoral bowing in Japanese population

    Directory of Open Access Journals (Sweden)

    Abdelaal Ahmed Hamed Kassem

    2016-01-01

    Full Text Available Introduction: Differences in the magnitude of bowing between races are well-known characteristics of the femur. Asian races have an increased magnitude of femoral bowing but most of the orthopedic implants designed for the femur do not match this exaggerated bowing. We calculated the sagittal and coronal femoral bowing in the Japanese population at different levels of the femur and addressed its surgical significance. Material and methods: We calculated the sagittal and coronal bowing of 132 Japanese femora using CT scan of the femur. A mathematical calculation of the radius of curvature at proximal, middle, and distal regions of the femur was used to determine the degree of femoral bowing. Results: Mean sagittal bowing of the femur was 581, 188, and 161 mm for the proximal, middle, and distal thirds of the femur and mean lateral bowing was 528, 5092, and 876 mm, respectively. Mean sagittal and coronal bowing for the whole femur was 175 and 2640 mm, respectively. No correlation was found between age, gender, length of femur, and the degree of bowing. Conclusion: Our study reveals that femoral bowing in the Japanese population is 175 mm in the sagittal plane and 2640 mm in the coronal plane; these values are greater than the femoral bowing in other ethnic groups studied in the literature. This may result in varying degrees of mismatch between the western-manufactured femoral intramedullary implants and the Japanese femur. We recommend that orthopedic surgeons to accurately perform preoperative evaluation of the femoral bowing to avoid potential malalignment, rotation, and abnormal stresses between the femur and implant.

  12. Radiographic femoral varus measurement is affected unpredictably by femoral rotation

    DEFF Research Database (Denmark)

    Miles, James Edward

    Radiographic measurements of femoral varus are used to determine if intervention to correct femoral deformity is required, and to calculate the required correction. The varus angle is defined as the angle between the proximal femoral long axis (PFLA) and an axis tangential to the distal femoral...... and externally by 5° and 10° using plastic wedges. Accuracy of rotation was within +1°. Digital radiographs were obtained at each position. Varus angles were measured using ImageJ, employing two definitions of PFLA. Mean varus angles increased with 10° of either internal or external rotation with both PFLA...... rotation angles. The effect of rotation on varus angle measurements in these femoral specimens contradicts a previous report using CT. The most probable explanation is the difference in femoral positioning: the CT study used a slightly elevated position compared to that in this study, resulting in better...

  13. Tunnelling through a Gaussian random barrier

    International Nuclear Information System (INIS)

    Bezak, Viktor

    2008-01-01

    A thorough analysis of the tunnelling of electrons through a laterally inhomogeneous rectangular barrier is presented. The barrier height is defined as a statistically homogeneous Gaussian random function. In order to simplify calculations, we assume that the electron energy is low enough in comparison with the mean value of the barrier height. The randomness of the barrier height is defined vertically by a constant variance and horizontally by a finite correlation length. We present detailed calculations of the angular probability density for the tunnelled electrons (i.e. for the scattering forwards). The tunnelling manifests a remarkably diffusive character if the wavelength of the electrons is comparable with the correlation length of the barrier

  14. Drifting Diaphyses: Asymmetry in Diametric Growth and Adaptation Along the Humeral and Femoral Length.

    Science.gov (United States)

    Maggiano, Isabel S; Maggiano, Corey M; Tiesler, Vera G; Chi-Keb, Julio R; Stout, Sam D

    2015-10-01

    This study quantifies regional histomorphological variation along the human humeral and femoral diaphysis in order to gain information on diaphyseal growth and modeling drift patterns. Three thin sections at 40, 50, and 60% bone length were prepared from a modern Mexican skeletal sample with known age and sex to give a longitudinal perspective on the drifting cortex (12 adults and juveniles total, 7 male and 5 female). Point-count techniques were applied across eight cross-sectional regions of interest using the starburst sampling pattern to quantify percent periosteal and endosteal primary lamellar bone at each diaphyseal level. The results of this study show a posterio-medial drift pattern in the humerus with a posterior rotational trend along the diaphysis. In the femur, we observed a consistent lateral to anteriolateral drift and an increase in primary lamellar bone area of both, periosteal and endosteal origin, towards the distal part of the diaphysis. These observations characterize drifting diaphyses in greater detail, raising important questions about how to resolve microscopic and macroscopic cross-sectional analysis towards a more complete understanding of bone growth and mechanical adaptation. Accounting for modeling drift has the potential to positively impact age and physical activity estimation, and explain some of the significant regional variation in bone histomorphology seen within (and between) bone cross-sections due to differing ages of tissue formation. More study is necessary, however, to discern between possible drift scenarios and characterize populational variation. © 2015 Wiley Periodicals, Inc.

  15. Relationship between Widening and Position of the Tunnels and Clinical Results of Anterior Cruciate Ligament Reconstruction to Knee Osteoarthritis: 30 Patients at a Minimum Follow-Up of 10 Years.

    Science.gov (United States)

    Ayala-Mejias, Juan Diego; Garcia-Gonzalez, Benjamin; Alcocer-Perez-España, Luis; Villafañe, Jorge Hugo; Berjano, Pedro

    2017-07-01

    To evaluate the relationship between tunnel position and widening and long-term clinical results in anterior cruciate ligament (ACL) reconstruction, a retrospective cohort of 30 patients undergoing ACL reconstruction with double semitendinous plus double gracilis (SAC technique) with longer than 10-year follow-up was selected. CT scans in the first 3 months and at final follow-up was evaluated. Position, angle, and widening of tunnels including Nebelung criteria were recorded in all CT scans. Physical, KT-1000, and clinical evaluation were performed at final follow-up. Outcomes and knee arthritis severity were evaluated at final follow-up. Mean follow-up was 11.2 ± 1.2. At final follow-up, 85 and 57% of tibial and femoral tunnels, respectively, developed some degree of enlargement. Frontal tibial angle (mean) was 72°, sagittal tibial angle 63°, frontal femoral angle 47°, sagittal femoral angle 20°, and tunnels divergence angle 36°. Preoperatively, KT-1000 30L and Lachman test scores were 5.52 and 5.79 respectively. In the last follow-up, 30L and manual Lachman test scores were 0.97 and 1.13, respectively ( p  verticalization. Tibial tunnel dilation was associated with long-term degenerative changes but not with final knee instability. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Risk Factors and Clinical Evaluation of Superficial Femoral Artery Stent Fracture: Prote'ge'GPS Stent

    International Nuclear Information System (INIS)

    Lee, Da Un; Kim, Jae Kyu; Jung, Hye Doo; Huh, Tae Wook; Yim, Nam Yeol; Oh, Hyun jun; Choi, Soo Jin Na; Chang, Nam Kyu

    2010-01-01

    To evaluate the occurrence of superficial femoral artery stent fractures, the risk factors of stent fracture, and the relationship between fractures and clinical findings. Of the 38 patients who underwent treatment with Prote'ge'GPS stenting due to arterial occlusions on the superficial femoral artery, 17 also underwent a clinical analysis. Forty-three stents were inserted in the 17 superficial femoral arteries, ranging between 15 and 50 cm in length, with a mean treated length of 26.4 cm (15-50 cm). A fracture was evaluated by taking a PA and lateral simple radiography, as well as a follow-up evaluation accompanied with a CT angiography, DSA, and a color Doppler sonography. The examination involved the assessment of the difference between bone fractures due to length, placement, and frequency. Fractures occurred in 13 of 43 stents (30.2%). A total of 10 (71.4%) occurred in the upper third, compared to 4 (28.6%) in the lower third of the superficial femoral artery. In addition, 10 stents (71.4%) had a single strut fracture, whereas 4 (28.6%) had multiple strut fractures. A stent fracture occurred more frequently when the stents and lesions were longer (p=0.021, 0.012) and the stents were inserted near the joint. However, there was no significant relationship between stent numbers and the fractures (p=0.126). When the stents were inserted along the popliteal artery, a stent fracture occurred more frequently in the lower third of the artery. The stent fractures did not significantly influence the patency rate of the stented artery (p=0.44) Prote'ge'GPS stents in the superficial femoral artery revealed a considerable number of fractures and the fracture frequency showed a significant relationship with the length of stents and lesions. The closer stent insertion was to the joints, the more frequently fractures occurred. There were no evident significant relationships between the presence of stent fractures and the patency of the stented arteries

  17. Application of monorail fixator for femoral gap nonunion.

    Science.gov (United States)

    Agrawal, Hemendra-Kumar; Jaiman, Ashish; Khatkar, Vipin; Sharma, Vinod-Kumar

    2014-01-01

    Difficult femoral nonunion takes account of infective nonunion and aseptic gap nonunion. Limb length discrepancy and nonunion need to be tackled simultaneously. Conventionally Ilizarov ring fixator is in vogue but it has some limitations. To overcome these, monorail fixator is an effective alternative. Persistent good results can be obtained if we can get a perfect anatomical alignment and good regeneration.

  18. Engineering of multi-segmented light tunnel and flattop focus with designed axial lengths and gaps

    Science.gov (United States)

    Yu, Yanzhong; Huang, Han; Zhou, Mianmian; Zhan, Qiwen

    2018-01-01

    Based on the radiation pattern from a sectional-uniform line source antenna, a three-dimensional (3D) focus engineering technique for the creation of multi-segmented light tunnel and flattop focus with designed axial lengths and gaps is proposed. Under a 4Pi focusing system, the fields radiated from sectional-uniform magnetic and electromagnetic current line source antennas are employed to generate multi-segmented optical tube and flattop focus, respectively. Numerical results demonstrate that the produced light tube and flattop focus remain homogeneous along the optical axis; and their lengths of the nth segment and the nth gap between consecutive segments can be easily adjusted and only depend on the sizes of the nth section and the nth blanking between adjacent sectional antennas. The optical tube is a pure azimuthally polarized field but for the flattop focus the longitudinal polarization is dominant on the optical axis. To obtain the required pupil plane illumination for constructing the above focal field with prescribed characteristics, the inverse problem of the antenna radiation field is solved. These peculiar focusing fields might find potential applications in multi-particle acceleration, multi-particle trapping and manipulation.

  19. Bone tunnel change develops within two weeks of double-bundle anterior cruciate ligament reconstruction using hamstring autograft: A comparison of different postoperative immobilization periods using computed tomography.

    Science.gov (United States)

    Shimizu, Ryo; Adachi, Nobuo; Ishifuro, Minoru; Nakamae, Atsuo; Ishikawa, Masakazu; Deie, Masataka; Ochi, Mitsuo

    2017-10-01

    The purpose of this study was to evaluate bone tunnel changes following anterior cruciate ligament (ACL) reconstruction during the early postoperative period using computed tomography (CT), and to understand the impact of postoperative immobilization on these changes. Twenty patients who underwent double-bundle ACL reconstruction using hamstring tendon autografts were included. We subcategorized patients into two groups: patients who underwent isolated ACL reconstruction and had three days of knee immobilization (Group A, n=10); and patients with concomitant meniscus injuries who underwent ACL reconstruction and meniscus repair simultaneously (Group B, n=10) had their knees immobilized for two weeks after surgery. Bone tunnel enlargement was evaluated using CT imaging at one to three days, two weeks, one month, three months and six months after surgery. The cross-sectional area of the femoral and tibial tunnels was measured, and enlargement rate was calculated. The tunnel center location at two weeks after surgery was also evaluated. The mean cross-sectional area adjacent to the joint space of the femoral and tibial tunnels significantly increased immediately after surgery, especially in the first month (P0.01). There was no significant difference in tunnel enlargement rate between group A and B. Tunnel center location changed even in the first two weeks. Bone tunnel enlargement following double-bundle ACL reconstruction occurred at an earlier time point after surgery than anticipated. Postoperative immobilization could not prevent bone tunnel enlargement, but might prevent tunnel migration. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Leg lengthening and femoral-offset reduction after total hip arthroplasty: where is the problem - stem or cup positioning?

    Science.gov (United States)

    Al-Amiry, Bariq; Mahmood, Sarwar; Krupic, Ferid; Sayed-Noor, Arkan

    2017-09-01

    Background Restoration of femoral offset (FO) and leg length is an important goal in total hip arthroplasty (THA) as it improves functional outcome. Purpose To analyze whether the problem of postoperative leg lengthening and FO reduction is related to the femoral stem or acetabular cup positioning or both. Material and Methods Between September 2010 and April 2013, 172 patients with unilateral primary osteoarthritis treated with THA were included. Postoperative leg-length discrepancy (LLD) and global FO (summation of cup and FO) were measured by two observers using a standardized protocol for evaluation of antero-posterior plain hip radiographs. Patients with postoperative leg lengthening ≥10 mm (n = 41) or with reduced global FO >5 mm (n = 58) were further studied by comparing the stem and cup length of the operated side with the contralateral side in the lengthening group, and by comparing the stem and cup offset of the operated side with the contralateral side in the FO reduction group. We evaluated also the inter-observer and intra-observer reliability of the radiological measurements. Results Both observers found that leg lengthening was related to the stem positioning while FO reduction was related to the positioning of both the femoral stem and acetabular cup. Both inter-observer reliability and intra-observer reproducibility were moderate to excellent (intra-class correlation co-efficient, ICC ≥0.69). Conclusion Post THA leg lengthening was mainly caused by improper femoral stem positioning while global FO reduction resulted from improper positioning of both the femoral stem and the acetabular cup.

  1. Three-stage treatment protocol for recalcitrant distal femoral nonunion.

    Science.gov (United States)

    Ma, Ching-Hou; Chiu, Yen-Chun; Tu, Yuan-Kun; Yen, Cheng-Yo; Wu, Chin-Hsien

    2017-04-01

    In this study, we proposed a three-stage treatment protocol for recalcitrant distal femoral nonunion and aimed to analyze the clinical results. We retrospective reviewed 12 consecutive patients with recalcitrant distal femoral nonunion undergoing our three-stage treatment protocol from January 2010 to December 2014 in our institute. The three-stage treatment protocol comprised debridement of the nonunion site, lengthening to eliminate leg length discrepancy, deformity correction, stabilization with a locked plate, filling of the defect with cement spacer for inducing membrane formation, and bone reconstruction using a cancellous bone autograft (Masquelet technique) or free vascularized fibular bone graft. The bone union time, wound complication, lower limbs alignment, amount of lengthening, knee range of motion, and functional outcomes were evaluated. Osseous union with angular deformity lengthening was 5.88 cm (range 3.5-12 cm). Excellent or good outcomes were obtained in 9 patients. Although the current study involved only a small number of patients and the intervention comprised three stages, we believe that such a protocol may be a valuable alternative for the treatment of recalcitrant distal femoral nonunion.

  2. The surgical treatment of ilio-femoral venous obstruction.

    Science.gov (United States)

    Illuminati, G; Caliò, F G; D'Urso, A; Mancini, P; Papaspyropoulos, V; Ceccanei, G; Lorusso, R; Vietri, F

    2004-01-01

    A series of 9 patients of a mean age of 48 years, operated on for compression of the ilio-femoral venous axis is reported. The cause of obstruction was external compression in 3 cases, a retroperitoneal sarcoma in 1 case, and an infrarenal aortic aneurysm in 2. Two patients presented with a Cockett's syndrome, 3 with a chronic ilio-femoral thrombosis, and one with a post-traumatic segmentary stenosis. Treatment consisted in a resection/Dacron grafting of 2 infrarenal aortic aneurysms, one femoro-caval bypass graft, 2 transpositions of the right common iliac artery in the left hypogastric artery for Cockett's syndrome, 3 Palma's operations for chronic thrombosis, and one internal jugular vein interposition for segmentary stenosis. There were no postoperative deaths and no early thromboses of venous reconstructions performed. All the patients were relieved of symptoms during the follow-up period, whose mean length was 38 months. The cause of venous obstruction and the presence of symptoms which are resistant to medical treatment are the main indications to ilio-femoral venous revascularization. The choice of the optimal treatment in each single case yields satisfactory results.

  3. Femoral nerve damage (image)

    Science.gov (United States)

    The femoral nerve is located in the leg and supplies the muscles that assist help straighten the leg. It supplies sensation ... leg. One risk of damage to the femoral nerve is pelvic fracture. Symptoms of femoral nerve damage ...

  4. Femoral rotation unpredictably affects radiographic anatomical lateral distal femoral angle measurements

    DEFF Research Database (Denmark)

    Miles, James Edward

    2016-01-01

    Objective: To describe the effects of internal and external femoral rotation on radiographic measurements of the anatomical lateral distal femoral angle (a-LDFA) using two methods for defining the anatomical proximal femoral axis (a-PFA). Methods: Digital radiographs were obtained of 14 right...... femora at five degree intervals from 10° external rotation to 10° internal rotation. Using freely available software, a-LDFA measurements were made using two different a-PFA by a single observer on one occasion. Results: Mean a-LDFA was significantly greater at 10° external rotation than at any other...... rotation. The response of individual femora to rotation was unpredictable, although fairly stable within ±5° of zero rotation. Mean a-LDFA for the two a-PFA methods differed by 1.5°, but were otherwise similarly affected by femoral rotation. Clinical significance: If zero femoral elevation can be achieved...

  5. Recanalization of superficial femoral artery by retrograde approach via popliteal artery

    International Nuclear Information System (INIS)

    Kim, Jae Kyu; Kim, Hyung Kil; Yun, Ung; Seo, Jeong Jin; Kang, Heoung Keun

    1995-01-01

    To recanalize the occlusive lesion of superficial femoral artery at origin site by retrograde approach via popliteal artery. 15 patients, who were poor surgical candidates due to coronary artery disease and who had severe occlusive lesion of superficial femoral artery close to its origin with good distal runoffs to popliteal artery, were selected. Patients were all men and range of age were from 53 years to 66 years (mean age: 63 years). Range of lesion length were from 15 cm to 30 cm (mean length: 22.4 cm). Localization of popliteal artery was done with Doppler stethoscope or 'road-map' DSA. The method of recanalization were transluminal endarterectomy catheter (TEC), TEC and angioplasty, thrombolysoangioplasty (TLA). Retrograde puncture of popliteal artery was done in 15 patients successfully. TEC and PTA was performed in 9 patients, TEC only in 2 patients, and TLA and PTA in 2 patients. During the follow-up period of 5 months to 2 years reocclusion did not occur in 10 patients except for 1 patient with poor cardiac output in whom it occurred 1 day later. Remained 4 patients were lost in follow up. Any neurologic or vascular complication did not occur. Retrograde approach of superficial femoral artery via popliteal artery in patients with difficult vascular intervention by common method provides a useful, alternative recanalization method

  6. Recanalization of superficial femoral artery by retrograde approach via popliteal artery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Kyu; Kim, Hyung Kil; Yun, Ung; Seo, Jeong Jin; Kang, Heoung Keun [Chonnam University Medical School, Kwangju (Korea, Republic of)

    1995-09-15

    To recanalize the occlusive lesion of superficial femoral artery at origin site by retrograde approach via popliteal artery. 15 patients, who were poor surgical candidates due to coronary artery disease and who had severe occlusive lesion of superficial femoral artery close to its origin with good distal runoffs to popliteal artery, were selected. Patients were all men and range of age were from 53 years to 66 years (mean age: 63 years). Range of lesion length were from 15 cm to 30 cm (mean length: 22.4 cm). Localization of popliteal artery was done with Doppler stethoscope or 'road-map' DSA. The method of recanalization were transluminal endarterectomy catheter (TEC), TEC and angioplasty, thrombolysoangioplasty (TLA). Retrograde puncture of popliteal artery was done in 15 patients successfully. TEC and PTA was performed in 9 patients, TEC only in 2 patients, and TLA and PTA in 2 patients. During the follow-up period of 5 months to 2 years reocclusion did not occur in 10 patients except for 1 patient with poor cardiac output in whom it occurred 1 day later. Remained 4 patients were lost in follow up. Any neurologic or vascular complication did not occur. Retrograde approach of superficial femoral artery via popliteal artery in patients with difficult vascular intervention by common method provides a useful, alternative recanalization method.

  7. External fixation for closed pediatric femoral shaft fractures: where are we now?

    Science.gov (United States)

    Kong, Heather; Sabharwal, Sanjeev

    2014-12-01

    Recent advances in external fixation technique and pin design have sought to minimize complications such as pin site infection and premature removal of the external fixator. Although newer forms of internal fixation have gained popularity, external fixation may still have a role in managing pediatric femoral shaft fractures. We sought to assess the time to healing, limb alignment, and complications observed in a cohort of pediatric patients with closed femoral shaft fractures who were treated with external fixation. Over a 15-year period, one surgeon treated 289 pediatric patients with femur fractures, 31 (11%) of whom received an external fixator. The general indications for use of an external fixator during the period in question included length-unstable fractures, metadiaphyseal location, refracture, and pathologic fracture. Six patients (19%) had inadequate followup data and four patients (13%) were treated with a combination of flexible intramedullary nails and external fixation, leaving 21 patients for analysis. Mean age at injury was 10 years (range, 6-15 years) and followup averaged 22 months (range, 5-45 months) after removal of the fixator. Radiographs were examined for alignment and limb length discrepancy. Complications were recorded from a chart review. Mean time in the fixator was 17 weeks (range, 9-24 weeks). One patient sustained a refracture and one patient with an isolated femur fracture had a leg length discrepancy > 2 cm. There were no pin site infections requiring intravenous antibiotics or additional surgery. One patient with Blount disease and previous tibial osteotomy developed transient peroneal nerve palsy. Despite improvements in pin design and predictable fracture healing, complications such as refracture and leg length discrepancy after external fixation of pediatric femoral shaft fractures can occur. However, external fixation remains a viable alternative for certain fractures such as length-unstable fractures, metadiaphyseal

  8. 99mTc-MDP scintigraphy of femoral head necrosis following femoral neck fracture

    International Nuclear Information System (INIS)

    Lee, Soon Jin; Lee, Jun Hyung; Kim, Eun Kyung; Lee, Sun Wha; Kim, Soon Yong

    1985-01-01

    Secondary ischemic necrosis of femoral head due to loss of blood supply following to femoral neck fracture is well known. The regional distribution of bone-seeking radiopharmaceuricals in the skeleton can depend on a number of factors, but bone blood flow is a major physiological determinant of regional skeletal uptake of Tc-99m polyphosphate and bone imaging may thus be used for the evaluation of vascularity of the femoral head. The authors made a comparative study of scintigraphic findings and operative findings of 28 cases of femoral neck fracture treated at Kyung Hee University Hospital from April 1980 to May 1984. The results were as follows: 1. In 16 cases of proven avascular necorsis of femoral head, scintigraphy showed absent or decreased activity in 14 cases (87.5%), while radiography showed increased density in 10 cases (62.5%). 2. In 12 cases of proven vital femoral head, scintigraphy showed increased activity in 9 cases (75%) and radiography showed decreased density in 9 cases (75%). 3. 99mTc-MDP scintigraphy was an excellent and useful method for assessing bone vitality of femoral head

  9. Application of monorail fixator for femoral gap nonunion

    Directory of Open Access Journals (Sweden)

    Agrawal Hemendra Kumar

    2014-07-01

    Full Text Available 【Abstract】Difficult femoral nonunion takes account of infective nonunion and aseptic gap nonunion. Limb length discrepancy and nonunion need to be tackled simultaneously. Conventionally Ilizarov ring fixator is in vogue but it has some limitations. To overcome these, monorail fixator is an effective alternative. Persistent good results can be obtained if we can get a perfect anatomical alignment and good regeneration. Key words: Femur; Ilizarov technique; External fixators

  10. Femoral shaft fractures in children: elastic stable intramedullary nailing in 31 cases

    DEFF Research Database (Denmark)

    Houshian, Shirzad; Gøthgen, Charlotte Buch; Pedersen, Niels Wisbech

    2004-01-01

    We report our experience with elastic stable intramedullary titanium nailing (ESIN) of femoral shaft fractures in children. From 1998 to 2001, we treated 31 children (20 boys), median age 6 (4-11) years, with ESIN for 29 closed and 2 grade I open femoral shaft fractures. We reviewed 30 children...... clinically after median 1.5 (1-3) years. Their median hospital stay was 6 (2-20) days. All fractures were radiographically united at a median of 7 (5-9) weeks. The nails were removed in 29 children after a median of 22 (6-38) weeks postoperatively. At follow-up, we found a leg-length discrepancy up to 1 cm...

  11. Anatomic variability of the vascularized composite osteomyocutaneous flap from the medial femoral condyle: an anatomical study

    Directory of Open Access Journals (Sweden)

    Trung-Hau Le Thua

    2014-12-01

    Full Text Available Aim: The anatomical study and clinical application for the vascularized corticoperiosteal flap from the medial femoral condyle have been performed and described previously. Although prior studies have described the composite osteomyocutaneous flap from the medial femoral condyle, a detailed analysis of the vascularity of this region has not yet been fully evaluated. Methods: This anatomical study described the variability of the arteries from the medial femoral condyle in 40 cadaveric specimens. Results: The descending genicular artery (DGA was found in 33 of 40 cases (82.5%. The  superomedial genicular artery (SGA was present in 10 cases (25%. All 33 cases (100% of the DGA had articular branches to the periosteum of the medial femoral condyle. Muscular branches and saphenous branches of the DGA were present in 25 cases (62.5% and 26 cases (70.3%, respectively. Conclusion: The current study demonstrates that the size and length of the vessels to the medial femoral condyle are sufficient for a vascularized bone flap. A careful preoperative vascular assessment is essential prior to use of the vascularized composite osteomyocutaneous flap from the medial femoral condyle, because of the considerable anatomical variations in different branches of the DGA.

  12. ediatric femoral shaft fractures treated by flexible intramedullary nailing.

    Science.gov (United States)

    Kapil Mani, K C; Dirgha Raj, R C; Parimal, Acharya

    2015-01-01

    Nowadays pediatric femoral fractures are more commonly managed with operative treatment rather than conservative treatment because of more rapid recovery and avoidance of prolonged immobilization. Children between the ages of 5-13 years are treated either by traction plus hip spica and flexible/elastic stable retrograde intramedullary nail, or external fixators in the case of open fractures. The aim of this study is to evaluate the outcome of pediatric femoral shaft fractures treated by stainless steel flexible intramedullary nail in children between 5 and 13 years of age. There were 32 cases of femoral shaft fractures which were all fixed with stainless steel flexible intramedullary nail under fluoroscopy. Long leg cast was applied at the time of fixation. Partial weight bearing was started 2 weeks after surgery. Patients were evaluated in follow-up study to observe the alignment of fracture, infection, delayed union, nonunion, limb length discrepancy, motion of knee joint, and time to unite the fracture. We were able to follow up 28 out of 32 patients. The patients were 8.14 years of age on average. The mean hospital stay after operation was 4 days and fracture union time was 9.57 weeks. There were 3 cases of varus angulation, 2 cases of anterior angulation, and 4 cases of limb lengthening. Patients aged between 5 and 13 years treated with flexible intramedullary nail for closed femoral shaft fracture have rapid union and recovery, short rehabilitation period, less immobilization and psychological impact, and cost-effective.

  13. Evaluation of perfusion of the femoral head after femoral neck fracture using bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Satoshi; Ishido, Yasuhiro [Saiseikai Sendai Hospital, Kagoshima (Japan); Okano, Toshihiro [Ibusuki National Hospital, Kagoshima (Japan); Komiya, Setsuro [Kagoshima Univ. (Japan). Faculty of Medicine

    2002-09-01

    We treated 13 patients for femoral neck fracture. They consisted of 2 males and 11 females, and were classified according to Garden stage classification; Stage I, 3 cases; Stage II, 2 cases; Stage III, 2 cases; Stage IV, 4 cases. Two trochanteric fracture cases were used by control. We evaluated perfusion of the femoral head after femoral neck fracture using bone scintigraphy, which is considered useful for evaluation of perfusion of the femoral neck before operation. (author)

  14. Evaluation of perfusion of the femoral head after femoral neck fracture using bone scintigraphy

    International Nuclear Information System (INIS)

    Yamaguchi, Satoshi; Ishido, Yasuhiro; Okano, Toshihiro; Komiya, Setsuro

    2002-01-01

    We treated 13 patients for femoral neck fracture. They consisted of 2 males and 11 females, and were classified according to Garden stage classification; Stage I, 3 cases; Stage II, 2 cases; Stage III, 2 cases; Stage IV, 4 cases. Two trochanteric fracture cases were used by control. We evaluated perfusion of the femoral head after femoral neck fracture using bone scintigraphy, which is considered useful for evaluation of perfusion of the femoral neck before operation. (author)

  15. Tunneling Flight Time, Chemistry, and Special Relativity.

    Science.gov (United States)

    Petersen, Jakob; Pollak, Eli

    2017-09-07

    Attosecond ionization experiments have not resolved the question "What is the tunneling time?". Different definitions of tunneling time lead to different results. Second, a zero tunneling time for a material particle suggests that the nonrelativistic theory includes speeds greater than the speed of light. Chemical reactions, occurring via tunneling, should then not be considered in terms of a nonrelativistic quantum theory calling into question quantum dynamics computations on tunneling reactions. To answer these questions, we define a new experimentally measurable paradigm, the tunneling flight time, and show that it vanishes for scattering through an Eckart or a square barrier, irrespective of barrier length or height, generalizing the Hartman effect. We explain why this result does not lead to experimental measurement of speeds greater than the speed of light. We show that this tunneling is an incoherent process by comparing a classical Wigner theory with exact quantum mechanical computations.

  16. Interfacial density of states in magnetic tunnel junctions

    NARCIS (Netherlands)

    LeClair, P.R.; Kohlhepp, J.T.; Swagten, H.J.M.; Jonge, de W.J.M.

    2001-01-01

    Large zero-bias resistance anomalies as well as a collapse of magnetoresistance were observed in Co/Al2O3/Co magnetic tunnel junctions with thin Cr interfacial layers. The tunnel magnetoresistance decays exponentially with nominal Cr interlayer thickness with a length scale of ~1 Å more than twice

  17. {sup 99m}Tc-MDP scintigraphy of femoral head necrosis following femoral neck fracture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soon Jin; Lee, Jun Hyung; Kim, Eun Kyung; Lee, Sun Wha; Kim, Soon Yong [Kyung Hee University School of Medicine, Seoul (Korea, Republic of)

    1985-02-15

    Secondary ischemic necrosis of femoral head due to loss of blood supply following to femoral neck fracture is well known. The regional distribution of bone-seeking radiopharmaceuricals in the skeleton can depend on a number of factors, but bone blood flow is a major physiological determinant of regional skeletal uptake of Tc-99m polyphosphate and bone imaging may thus be used for the evaluation of vascularity of the femoral head. The authors made a comparative study of scintigraphic findings and operative findings of 28 cases of femoral neck fracture treated at Kyung Hee University Hospital from April 1980 to May 1984. The results were as follows: 1. In 16 cases of proven avascular necorsis of femoral head, scintigraphy showed absent or decreased activity in 14 cases (87.5%), while radiography showed increased density in 10 cases (62.5%). 2. In 12 cases of proven vital femoral head, scintigraphy showed increased activity in 9 cases (75%) and radiography showed decreased density in 9 cases (75%). 3. 99mTc-MDP scintigraphy was an excellent and useful method for assessing bone vitality of femoral head.

  18. Concurrent myotomy and tunneling after establishment of a half tunnel instead of myotomy after establishment of a full tunnel: a more efficient method of peroral endoscopic myotomy.

    Science.gov (United States)

    Philips, George M; Dacha, Sunil; Keilin, Steve A; Willingham, Field F; Cai, Qiang

    2016-04-01

    Peroral endoscopic myotomy (POEM) is a time-consuming and challenging procedure. Traditionally, the myotomy is done after the submucosal tunnel has been completed. Starting the myotomy earlier, after submucosal tunneling is half completed (concurrent myotomy and tunneling), may be more efficient. This study aims to assess if the method of concurrent myotomy and tunneling may decrease the procedural time and be efficacious. This is a retrospective case series of patients who underwent modified POEM (concurrent myotomy and tunneling) or traditional POEM at a tertiary care medical center. Modified POEM or traditional POEM was performed at the discretion of the endoscopist in patients presenting with achalasia. The total procedural duration, myotomy duration, myotomy length, and time per unit length of myotomy were recorded for both modified and traditional POEM. Modified POEM was performed in 6 patients whose mean age (± standard deviation [SD]) was 58 ± 13.3 years. Of these, 5 patients had type II achalasia and 1 patient had esophageal dysmotility. The mean Eckardt score (± SD) before the procedure was 8.8 ± 1.3. The modified technique was performed in 47 ± 8 minutes, with 6 ± 1 minutes required per centimeter of myotomy and 3 ± 1 minutes required per centimeter of submucosal space. The Eckardt score was 3 ± 1.1 at 1 month and 3 ± 2.5 at 3 months. The procedure time for modified POEM was significantly shorter than that for traditional POEM. Modified POEM with short submucosal tunneling may be more efficient than traditional POEM with long submucosal tunneling, and outcomes may be equivalent over short-term follow-up. Long-term data and randomized controlled studies are needed to compare the clinical efficacy of modified POEM with that of the traditional method.

  19. [A method to avoid lengthening lower limbs after total hip arthroplasty in patients with congenital short femoral neck].

    Science.gov (United States)

    Chen, Tao; Shang, Xifu; He, Rui; Hu, Fei; Ge, Chang

    2012-03-01

    To investigate the method to avoid lengthening lower limbs after total hip arthroplasty in patients with congenital short femoral neck. The clinical data were analyzed retrospectively from 38 patients undergoing unilateral total hip arthroplasty between April 2005 and December 2010. There were 26 males and 12 females, aged 45-78 years (mean, 62.3 years). Among these cases, there were 11 cases of avascular necrosis of the femoral head, 17 cases of hip osteoarthritis, and 10 cases of femoral neck fracture. Before operation, 29 cases had leg length discrepancy; and the shortened length of the legs was 10-24 mm with an average of 14.5 mm by clinical measurement, and was 11-25 mm with an average of 14.7 mm by X-ray film measurement. The Harris score before operation was 44.0 +/- 3.6. At 1 day after operation, 3 cases had legs lengthening by clinical and X-ray film measurement; limb length difference less than 10 mm was regarded as equal limb length in the other 35 patients (92.1%). All incisions healed by first intention, and no complication of infection or lower limb deep venous thrombosis occurred. In 3 patients who had legs lengthening, 1 patient had abnormal gait and slight limping after increasing heel pad because the lower limb was lengthened by 16 mm, and 2 patients had slight limping. The other patients could walk normally and achieved pain relief of hip. Thirty-six patients were followed up 12-68 months (mean, 43.8 months). The Harris score was 86.7 +/- 2.3 after 6 months, showing significant difference (t = 3.260, P = 0.031) when compared with that before operation. The X-ray films showed no prosthetic loosening or subsidence. For patients with congenital short femoral neck during total hip arthroplasty, the surgeons should pay attention to osteotomy plane determination, limb length measurement, and use of the prosthesis with collar to avoid the lengthening lower limbs.

  20. Location of civilian ballistic femoral fracture indicates likelihood of arterial injury.

    Science.gov (United States)

    Gitajn, Leah; Perdue, Paul; Hardcastle, John; O'Toole, Robert V

    2014-10-01

    We evaluated whether the location of a ballistic femoral fracture helps predict the presence of arterial injury. We hypothesized that fractures located in the distal third of the femur are associated with a higher rate of arterial injury. We conducted a retrospective review of electronic medical records at our level I trauma centre and found 133 consecutive patients with femoral fractures from civilian gunshots from 2002 to 2007, 14 of whom sustained arterial injury. Fracture extent was measured with computerized viewing software and recorded with a standard technique, calculating proximal, distal, and central locations of the fracture as a function of overall length of the bone. Analyses were conducted with Student's t, Chi-squared, and Fisher's exact tests. The location of any fracture line in the distal third of the femur was associated with increased risk of arterial injury (Pballistic injury is six times more likely to be associated with arterial injury and warrants careful evaluation. Our data show that fracture location can help alert clinicians to possible arterial injury after ballistic femoral fracture. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Quantum scattering in one-dimensional systems satisfying the minimal length uncertainty relation

    Energy Technology Data Exchange (ETDEWEB)

    Bernardo, Reginald Christian S., E-mail: rcbernardo@nip.upd.edu.ph; Esguerra, Jose Perico H., E-mail: jesguerra@nip.upd.edu.ph

    2016-12-15

    In quantum gravity theories, when the scattering energy is comparable to the Planck energy the Heisenberg uncertainty principle breaks down and is replaced by the minimal length uncertainty relation. In this paper, the consequences of the minimal length uncertainty relation on one-dimensional quantum scattering are studied using an approach involving a recently proposed second-order differential equation. An exact analytical expression for the tunneling probability through a locally-periodic rectangular potential barrier system is obtained. Results show that the existence of a non-zero minimal length uncertainty tends to shift the resonant tunneling energies to the positive direction. Scattering through a locally-periodic potential composed of double-rectangular potential barriers shows that the first band of resonant tunneling energies widens for minimal length cases when the double-rectangular potential barrier is symmetric but narrows down when the double-rectangular potential barrier is asymmetric. A numerical solution which exploits the use of Wronskians is used to calculate the transmission probabilities through the Pöschl–Teller well, Gaussian barrier, and double-Gaussian barrier. Results show that the probability of passage through the Pöschl–Teller well and Gaussian barrier is smaller in the minimal length cases compared to the non-minimal length case. For the double-Gaussian barrier, the probability of passage for energies that are more positive than the resonant tunneling energy is larger in the minimal length cases compared to the non-minimal length case. The approach is exact and applicable to many types of scattering potential.

  2. Structural and tunneling properties of Si nanowires

    KAUST Repository

    Montes Muñoz, Enrique

    2013-12-06

    We investigate the electronic structure and electron transport properties of Si nanowires attached to Au electrodes from first principles using density functional theory and the nonequilibrium Green\\'s function method. We systematically study the dependence of the transport properties on the diameter of the nanowires, on the growth direction, and on the length. At the equilibrium Au-nanowire distance we find strong electronic coupling between the electrodes and nanowires, which results in a low contact resistance. With increasing nanowire length we study the transition from metallic to tunneling conductance for small applied bias. For the tunneling regime we investigate the decay of the conductance with the nanowire length and rationalize the results using the complex band structure of the pristine nanowires. The conductance is found to depend strongly on the growth direction, with nanowires grown along the ⟨110⟩ direction showing the smallest decay with length and the largest conductance and current.

  3. Structural and tunneling properties of Si nanowires

    KAUST Repository

    Montes Muñ oz, Enrique; Gkionis, Konstantinos; Rungger, Ivan; Sanvito, Stefano; Schwingenschlö gl, Udo

    2013-01-01

    We investigate the electronic structure and electron transport properties of Si nanowires attached to Au electrodes from first principles using density functional theory and the nonequilibrium Green's function method. We systematically study the dependence of the transport properties on the diameter of the nanowires, on the growth direction, and on the length. At the equilibrium Au-nanowire distance we find strong electronic coupling between the electrodes and nanowires, which results in a low contact resistance. With increasing nanowire length we study the transition from metallic to tunneling conductance for small applied bias. For the tunneling regime we investigate the decay of the conductance with the nanowire length and rationalize the results using the complex band structure of the pristine nanowires. The conductance is found to depend strongly on the growth direction, with nanowires grown along the ⟨110⟩ direction showing the smallest decay with length and the largest conductance and current.

  4. Biomechanical optimization of different fixation modes for a proximal femoral L-osteotomy

    Directory of Open Access Journals (Sweden)

    Chen Hsih-Hao

    2009-09-01

    Full Text Available Abstract Background Numerous proposed surgical techniques have had minimal success in managing greater trochanter overgrowth secondary to retarded growth of the femoral capital epiphysis. For reconstruction of residual hip deformities, a novel type of proximal femur L-osteotomy was performed with satisfactory results. Although the clinical outcome was good, the biomechanical characteristics of the femur after such an osteotomy have not been clearly elucidated. Therefore, this study presents a three dimensional finite element analysis designed to understand the mechanical characteristics of the femur after the L-osteotomy. Methods A patient with left hip dysplasia was recruited as the study model for L-osteotomy. The normal right hip was used as a reference for performing the corrective surgery. Four FEA models were constructed using different numbers of fixation screws but the same osteotomy lengths together with four FEA models with the same number of fixation screws but different osteotomy lengths. The von Mises stress distributions and femoral head displacements were analyzed and compared. Results The results revealed the following: 1. The fixation devices (plate and screws sustained most of the external loading, and the peak value of von Mises stress on the fixation screws decreased with an increasing number of screws. 2. Additional screws are more beneficial on the proximal segment than on the distal segment for improving the stability of the postoperative femur. 3. The extent of osteotomy should be limited because local stress might be concentrated in the femoral neck region with increasing length of the L-osteotomy. Conclusion Additional screw placement on the proximal segment improves stability in the postoperative femur. The cobra-type plate with additional screw holes in the proximal area might improve the effectiveness of L-osteotomies.

  5. Correlation of ultrasound appearance, gross anatomy, and histology of the femoral nerve at the femoral triangle.

    Science.gov (United States)

    Lonchena, Tiffany K; McFadden, Kathryn; Orebaugh, Steven L

    2016-01-01

    Correlation between ultrasound appearance, gross anatomic characteristics, and histologic structure of the femoral nerve (FN) is lacking. Utilizing cadavers, we sought to characterize the anatomy of the FN, and provide a quantitative measure of its branching. We hypothesize that at the femoral crease, the FN exists as a group of nerve branches, rather than a single nerve structure, and secondarily, that this transition into many branches is apparent on ultrasonography. Nineteen preserved cadavers were investigated. Ultrasonography was sufficient to evaluate the femoral nerve in nine specimens; gross dissection was utilized in all 19. Anatomic characteristics were recorded, including distances from the inguinal ligament to femoral crease, first nerve branch, and complete arborization of the nerve. The nerves from nine specimens were excised for histologic analysis. On ultrasound, the nerve became more flattened, widened, and less discrete as it coursed distally. Branching of the nerve was apparent in 12 of 18 images, with mean distance from inguinal ligament of 3.9 (1.0) cm. However, upon dissection, major branching of the femoral nerve occurred at 3.1 (1.0) cm distal to the inguinal ligament, well proximal to the femoral crease. Histologic analysis was consistent with findings at dissection. The femoral nerve arborizes into multiple branches between the inguinal ligament and the femoral crease. Initial branching is often high in the femoral triangle. As hypothesized, the FN exists as a closely associated group of nerve branches at the level of the femoral crease; however, the termination of the nerve into multiple branches is not consistently apparent on ultrasonography.

  6. Treatment of neglected femoral neck fracture

    Directory of Open Access Journals (Sweden)

    Anil K Jain

    2015-01-01

    Full Text Available Intra-capsular femoral neck fractures are seen commonly in elderly people following a low energy trauma. Femoral neck fracture has a devastating effect on the blood supply of the femoral head, which is directly proportional to the severity of trauma and displacement of the fracture. Various authors have described a wide array of options for treatment of neglected/nonunion (NU femoral neck fracture. There is lack of consensus in general, regarding the best option. This Instructional course article is an analysis of available treatment options used for neglected femoral neck fracture in the literature and attempt to suggest treatment guides for neglected femoral neck fracture. We conducted the "Pubmed" search with the keywords "NU femoral neck fracture and/or neglected femoral neck fracture, muscle-pedicle bone graft in femoral neck fracture, fibular graft in femoral neck fracture and valgus osteotomy in femoral neck fracture." A total of 203 print articles were obtained as the search result. Thirty three articles were included in the analysis and were categorized into four subgroups based on treatment options. (a treated by muscle-pedicle bone grafting (MPBG, (b closed/open reduction internal fixation and fibular grafting (c open reduction and internal fixation with valgus osteotomy, (d miscellaneous procedures. The data was pooled from all groups for mean neglect, the type of study (prospective or retrospective, classification used, procedure performed, mean followup available, outcome, complications, and reoperation if any. The outcome of neglected femoral neck fracture depends on the duration of neglect, as the changes occurring in the fracture area and fracture fragments decides the need and type of biological stimulus required for fracture union. In stage I and stage II (Sandhu′s staging neglected femoral neck fracture osteosynthesis with open reduction and bone grafting with MPBG or Valgus Osteotomy achieves fracture union in almost 90

  7. Subtrochanteric femoral fracture during trochanteric nailing for the treatment of femoral shaft fracture.

    Science.gov (United States)

    Yun, Ho Hyun; Oh, Chi Hun; Yi, Ju Won

    2013-09-01

    We report on three cases of subtrochanteric femoral fractures during trochanteric intramedullary nailing for the treatment of femoral shaft fractures. Trochanteric intramedullary nails, which have a proximal lateral bend, are specifically designed for trochanteric insertion. When combined with the modified insertion technique, trochanteric intramedullary nails reduce iatrogenic fracture comminution and varus malalignment. We herein describe technical aspects of trochanteric intramedullary nailing for femoral shaft fractures to improve its application and prevent implant-derived complications.

  8. Evaluation of the Influence Caused by Tunnel Construction on Groundwater Environment: A Case Study of Tongluoshan Tunnel, China

    Directory of Open Access Journals (Sweden)

    Jian Liu

    2015-01-01

    Full Text Available Problems related to water inflow during tunnel construction are challenging to designers, workers, and management departments, as they can threaten tunneling project from safety, time, and economic aspects. Identifying the impacts on groundwater environment resulting from tunnel drainage and making a correct assessment before tunnel construction is essential to better understand troubles that would be encountered during tunnel excavation and helpful to adopt appropriate countermeasures to minimize the influences. This study presents an indicator system and quantifies each indicator of Tongluoshan tunnel, which is located in southwest China with a length of 5.2 km and mainly passes through carbonate rocks and sandstones, based on field investigation and related technological reports. Then, an evaluation is made using fuzzy comprehensive assessment method, with a result showing that it had influenced the local groundwater environment at a moderate degree. Information fed back from environmental investigation and hydrologic monitoring carried out during the main construction period proves the evaluation, as the flow of some springs and streams located beside the tunnel route was found experiencing an apparent decline.

  9. A-Frame free Vascularized Fibular Graft and Femoral Lengthening for Osteosarcoma Pediatric Patients.

    Science.gov (United States)

    Cashin, Megan; Coombs, Christopher; Torode, Ian

    2018-02-01

    Pediatric limb reconstruction after resection of a malignant tumor presents specific challenges. Multiple surgical techniques have been used to treat these patients. This paper describes a staged surgical technique for the reconstruction of large distal femoral defects due to tumor resection in skeletally immature patients. Three pediatric patients with osteosarcoma of the distal femur underwent staged reconstruction. Neoadjuvant chemotherapy was followed by en bloc tumor resection and immediate reconstruction of the distal femoral defect with a vascularized free fibular autograft utilizing a unique A-frame construct combined with intramedullary nail fixation. The second stage was a planned gradual lengthening of the healed construct, over a custom-made magnetically driven expandable intramedullary nail. All patients achieved bony union and satisfactory length with minimal complications. The patients all returned to full, unlimited physical activities. The early results confirm that the described technique is a safe and reliable procedure for the reconstruction of large femoral defects in pediatric patients with osteosarcoma. Level IV-therapeutic.

  10. Stuffing the nail: A simple technique for the extraction of a broken femoral nail.

    Science.gov (United States)

    Lovell, Jane; Krishna, Damodaran; Gehr, Eugene

    2017-06-01

    The extraction of broken femoral nails can be a challenging procedure and surgeons should be familiar with many different techniques. This paper demonstrates a case study and new, simple and cost effective technique for the removal of broken cannulated femoral nails. Our technique uses two guide wires of variable diameter and had several key points of differentiation from previous methods. Firstly, stuffing the nail with guide wires of greater total diameter than the cannula; secondly, reversing the second guide wire and finally, bending the tips of the wires. These innovations allow the technique to be used for narrow cannulated nails, superior purchase along the length of the nail, easy wire insertion and limited soft tissue damage. Our technique for the removal of broken femoral nails is quick, effective, cheap and easy to replicate and can be used by any generalist orthopaedic surgeon with basic equipment.

  11. Self-designed femoral neck guide pin locator for femoral neck fractures.

    Science.gov (United States)

    Xia, Shengli; Wang, Ziping; Wang, Minghui; Wu, Zuming; Wang, Xiuhui

    2014-01-01

    Closed reduction and fixation with 3 cannulated screws is a widely accepted surgery for the treatment of femoral neck fractures. However, how to obtain optimal screw placement remains unclear. In the current study, the authors designed a guide pin positioning system for femoral neck fracture cannulated screw fixation and examined its application value by comparing it with freehand guide needle positioning and with general guide pin locator positioning provided by equipment manufacturers. The screw reset rate, screw parallelism, triangle area formed by the link line of the entry point of 3 guide pins, and maximum vertical load bearing of the femoral neck after internal fixation were recorded. As expected, the triangle area was largest in the self-designed positioning group, followed by the general positioning group and the freehand positioning group. The difference among the 3 groups was statistically significant (P.05). The authors’ self-designed guide pin positioning system has the potential to accurately insert cannulated screws in femoral neck fractures and may reduce bone loss and unnecessary radiation.

  12. Single-magnon tunneling through a ferromagnetic nanochain

    International Nuclear Information System (INIS)

    Petrov, E.G.; Ostrovsky, V.

    2010-01-01

    Magnon transmission between ferromagnetic contacts coupled by a linear ferromagnetic chain is studied at the condition when the chain exhibits itself as a tunnel magnon transmitter. It is shown that dependently on magnon energy at the chain, a distant intercontact magnon transmission occurs either in resonant or off-resonant tunneling regime. In the first case, a transmission function depends weakly on the number of chain sites whereas at off-resonant regime the same function manifests an exponential drop with the chain length. Change of direction of external magnetic field in one of ferromagnetic contacts blocks a tunnel transmission of magnon.

  13. Using a calliper to restore the centre of the femoral head during total hip replacement.

    Science.gov (United States)

    Hill, J C; Archbold, H A P; Diamond, O J; Orr, J F; Jaramaz, B; Beverland, D E

    2012-11-01

    Restoration of leg length and offset is an important goal in total hip replacement. This paper reports a calliper-based technique to help achieve these goals by restoring the location of the centre of the femoral head. This was validated first by using a co-ordinate measuring machine to see how closely the calliper technique could record and restore the centre of the femoral head when simulating hip replacement on Sawbone femur, and secondly by using CT in patients undergoing hip replacement. Results from the co-ordinate measuring machine showed that the centre of the femoral head was predicted by the calliper to within 4.3 mm for offset (mean 1.6 (95% confidence interval (CI) 0.4 to 2.8)) and 2.4 mm for vertical height (mean -0.6 (95% CI -1.4 to 0.2)). The CT scans showed that offset and vertical height were restored to within 8 mm (mean -1 (95% CI -2.1 to 0.6)) and -14 mm (mean 4 (95% CI 1.8 to 4.3)), respectively. Accurate assessment and restoration of the centre of the femoral head is feasible with a calliper. It is quick, inexpensive, simple to use and can be applied to any design of femoral component.

  14. The effect of crystal size on tunneling phenomena in luminescent nanodosimetric materials

    Science.gov (United States)

    Pagonis, Vasilis; Bernier, Shannon; Vieira, Francisco Marques dos Santos; Steele, Shane

    2017-12-01

    The study of luminescence signals from nanodosimetric materials is an active research area, due to the many possible practical applications of such materials. In several of these materials it has been shown that quantum tunneling is a dominant mechanism for recombination processes associated with luminescence phenomena. This paper examines the effect of crystal size on quantum tunneling phenomena in nanocrystals, based on the assumption of a random distribution of electrons and positive ions. The behavior of such random distributions is determined by three characteristic lengths: the radius of the crystal R, the tunneling length a, and the initial average distance 〈d〉 between electrons and positive ions (which is directly related to the density of charges in the material). Two different cases are examined, depending on the relative concentrations of electrons and ions. In the first case the concentration of electrons is assumed to be much smaller than the concentration of positive ions. Examination of a previously derived analytical equation demonstrates two different types of crystal size effects. When the tunneling length a is much smaller than both R and 〈d〉, the analytical equations show that smaller crystals exhibit a faster tunneling recombination rate. However, when the tunneling length a is of the same order of magnitude as both R and 〈d〉, the opposite effect is observed, with smaller crystals exhibiting a slower tunneling recombination rate. As the crystal size increases, the rate of tunneling in both cases reaches the limit expected for bulk materials. In the second case we examine the situation where the concentrations of electrons and positive ions are equal at all times. In this situation there is no analytical equation available to describe the process, and the crystal size effects are simulated by using Monte Carlo (MC) techniques. The two opposite behaviors as a function of the crystal size are also observed in these MC simulations. The

  15. Comparison of Radial Access, Guided Femoral Access, and Non-Guided Femoral Access Among Women Undergoing Percutaneous Coronary Intervention.

    Science.gov (United States)

    Koshy, Linda M; Aberle, Laura H; Krucoff, Mitchell W; Hess, Connie N; Mazzaferri, Ernest; Jolly, Sanjit S; Jacobs, Alice; Gibson, C Michael; Mehran, Roxana; Gilchrist, Ian C; Rao, Sunil V

    2018-01-01

    This study was conducted to determine the association between radial access, guided femoral access, and non-guided femoral access on postprocedural bleeding and vascular complications after percutaneous coronary intervention (PCI). Bleeding events and major vascular complications after PCI are associated with increased morbidity, mortality, and cost. While the radial approach has been shown to be superior to the femoral approach in reducing bleeding and vascular complications, whether the use of micropuncture, fluoroscopy, or ultrasound mitigates these differences is unknown. We conducted a post hoc analysis of women in the SAFE-PCI for Women trial who underwent PCI and had the access method identified (n = 643). The primary endpoint of postprocedure bleeding or vascular complications occurring within 72 hours or at discharge was adjudicated by an independent clinical events committee and was compared based on three categories of access technique: radial, guided femoral (fluoroscopy, micropuncture, ultrasound), or non-guided femoral (none of the aforementioned). Differences between the groups were determined using multivariate logistic regression using radial access as the reference. Of the PCI population, 330 underwent radial access, 228 underwent guided femoral access, and 85 underwent non-guided femoral access. There was a statistically significant lower incidence of the primary endpoint with radial access vs non-guided femoral access; however, there was no significant difference between radial approach and femoral access guided by fluoroscopy, micropuncture, or ultrasound. This post hoc analysis demonstrates that while radial access is safer than non-guided femoral access, guided femoral access appears to be associated with similar bleeding events or vascular complications as radial access.

  16. Evaluation of a pig femoral head osteonecrosis model

    Directory of Open Access Journals (Sweden)

    Kim Harry

    2010-03-01

    Full Text Available Abstract Background A major cause of osteonecrosis of the femoral head is interruption of a blood supply to the proximal femur. In order to evaluate blood circulation and pathogenetic alterations, a pig femoral head osteonecrosis model was examined to address whether ligature of the femoral neck (vasculature deprivation induces a reduction of blood circulation in the femoral head, and whether transphyseal vessels exist for communications between the epiphysis and the metaphysis. We also tested the hypothesis that the vessels surrounding the femoral neck and the ligamentum teres represent the primary source of blood flow to the femoral head. Methods Avascular osteonecrosis of the femoral head was induced in Yorkshire pigs by transecting the ligamentum teres and placing two ligatures around the femoral neck. After heparinized saline infusion and microfil perfusion via the abdominal aorta, blood circulation in the femoral head was evaluated by optical and CT imaging. Results An angiogram of the microfil casted sample allowed identification of the major blood vessels to the proximal femur including the iliac, common femoral, superficial femoral, deep femoral and circumflex arteries. Optical imaging in the femoral neck showed that a microfil stained vessel network was visible in control sections but less noticeable in necrotic sections. CT images showed a lack of microfil staining in the epiphysis. Furthermore, no transphyseal vessels were observed to link the epiphysis to the metaphysis. Conclusion Optical and CT imaging analyses revealed that in this present pig model the ligatures around the femoral neck were the primary cause of induction of avascular osteonecrosis. Since the vessels surrounding the femoral neck are comprised of the branches of the medial and the lateral femoral circumflex vessels, together with the extracapsular arterial ring and the lateral epiphyseal arteries, augmentation of blood circulation in those arteries will improve

  17. Wind tunnel test of musi VI bridge

    Science.gov (United States)

    Permata, Robby; Andika, Matza Gusto; Syariefatunnisa, Risdhiawan, Eri; Hermawan, Budi; Noordiana, Indra

    2017-11-01

    Musi VI Bridge is planned to cross the Musi River in Palembang City, South Sumatera Province, Indonesia. The main span is a steel arch type with 200 m length and side span length is 75 m. Finite element analysis results showed that the bridge has frequency ratio for torsional and heaving mode (torsional frequency/heaving frequency)=1.14. This close to unity value rises concern about aerodynamic behaviour and stability of the bridge deck under wind loading. Sectional static and free vibration wind tunnel test were performed to clarify this phenomena in B2TA3 facility in Serpong, Indonesia. The test followed the draft of Guide of Wind Tunnel Test for Bridges developed by Indonesian Ministry of Public Works. Results from wind tunnel testing show that the bridge is safe from flutter instability and no coupled motion vibration observed. Therefore, low value of frequency ratio has no effect to aerodynamic behaviour of the bridge deck. Vortex-induced vibration in heaving mode occurred in relatively low wind velocity with permissible maximum amplitude value.

  18. Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study

    Directory of Open Access Journals (Sweden)

    Herrera Antonio

    2010-06-01

    Full Text Available Abstract Background Primary stability of the graft is essential in anterior cruciate ligament surgery. An optimal method of fixation should be easy to insert and provide great resistance against pull-out forces. A controlled laboratory study was designed to test the primary stability of ACL tendinous grafts in the tibial tunnel. The correlation between resistance to traction forces and the cross-section and length of the screw was studied. Methods The tibial phase of ACL reconstruction was performed in forty porcine tibias using digital flexor tendons of the same animal. An 8 mm tunnel was drilled in each specimen and two looped tendons placed as graft. Specimens were divided in five groups according to the diameter and length of the screw used for fixation. Wedge interference screws were used. Longitudinal traction was applied to the graft with a Servohydraulic Fatigue System. Load and displacement were controlled and analyzed. Results The mean loads to failure for each group were 295,44 N (Group 1; 9 × 23 screw, 564,05 N (Group 2; 9 × 28, 614,95 N (Group 3; 9 × 35, 651,14 N (Group 4; 10 × 28 and 664,99 (Group 5; 10 × 35. No slippage of the graft was observed in groups 3, 4 and 5. There were significant differences in the load to failure among groups (ANOVA/P Conclusions Longer and wider interference screws provide better fixation in tibial ACL graft fixation. Short screws (23 mm do not achieve optimal fixation and should be implanted only with special requirements.

  19. Lateral femoral traction pin entry: risk to the femoral artery and other medial neurovascular structures

    Directory of Open Access Journals (Sweden)

    Appleton Paul

    2010-01-01

    Full Text Available Abstract Background Femoral skeletal traction assists in the reduction and transient stabilization of pelvic, acetabular, hip, and femoral fractures when splinting is ineffective. Traditional teaching has recommended a medial entry site for insertion of the traction pin in order to minimize injury to the femoral artery as it passes through Hunter's canal. The present anatomical study evaluates the risk to the femoral artery and other medial neurovascular structures using a lateral entry approach. Methods Six embalmed cadavers (twelve femurs were obtained for dissection. Steinman pins were drilled from lateral to medial at the level of the superior pole of the patella, at 2 cm, and at 4 cm proximal to this point. Medial superficial dissection was then performed to identify the saphenous nerve, the superior medial geniculate artery, the adductor hiatus, the tendinous insertion of the adductor magnus and the femoral artery. Measurements localizing these anatomic structures relative to the pins were obtained. Results The femoral artery was relatively safe and was no closer than 29.6 mm (mean from any of the three Steinman pins. The superior medial geniculate artery was the medial structure at most risk. Conclusions Lateral femoral traction pin entry is a safe procedure with minimal risk to the saphenous nerve and femoral artery. Of the structures examined, only the superior medial geniculate artery is at a risk of iatrogenic injury due to its position. The incidence of such injury in clinical practice and its clinical significance is not known. Lateral insertion facilitates traction pin placement since it minimizes the need to move the contralateral extremity out of the way of the drilling equipment or the need to elevate or externally rotate the injured extremity relative to the contralateral extremity.

  20. Universal tunneling behavior in technologically relevant P/N junction diodes

    International Nuclear Information System (INIS)

    Solomon, Paul M.; Jopling, Jason; Frank, David J.; D'Emic, Chris; Dokumaci, O.; Ronsheim, P.; Haensch, W.E.

    2004-01-01

    Band-to-band tunneling was studied in ion-implanted P/N junction diodes with profiles representative of present and future silicon complementary metal-oxide-silicon (CMOS) field effect transistors. Measurements were done over a wide range of temperatures and implant parameters. Profile parameters were derived from analysis of capacitance versus voltage characteristics, and compared to secondary-ion mass spectroscopy analysis. When the tunneling current was plotted against the effective tunneling distance (tunneling distance corrected for band curvature) a quasi-universal exponential reduction of tunneling current versus, tunneling distance was found with an attenuation length of 0.38 nm, corresponding to a tunneling effective mass of 0.29 times the free electron mass (m 0 ), and an extrapolated tunneling current at zero tunnel distance of 5.3x10 7 A/cm 2 at 300 K. These results are directly applicable for predicting drain to substrate currents in CMOS transistors on bulk silicon, and body currents in CMOS transistors in silicon-on-insulator

  1. Impact of carbon nanotube length on electron transport in aligned carbon nanotube networks

    International Nuclear Information System (INIS)

    Lee, Jeonyoon; Stein, Itai Y.; Devoe, Mackenzie E.; Lewis, Diana J.; Lachman, Noa; Buschhorn, Samuel T.; Wardle, Brian L.; Kessler, Seth S.

    2015-01-01

    Here, we quantify the electron transport properties of aligned carbon nanotube (CNT) networks as a function of the CNT length, where the electrical conductivities may be tuned by up to 10× with anisotropies exceeding 40%. Testing at elevated temperatures demonstrates that the aligned CNT networks have a negative temperature coefficient of resistance, and application of the fluctuation induced tunneling model leads to an activation energy of ≈14 meV for electron tunneling at the CNT-CNT junctions. Since the tunneling activation energy is shown to be independent of both CNT length and orientation, the variation in electron transport is attributed to the number of CNT-CNT junctions an electron must tunnel through during its percolated path, which is proportional to the morphology of the aligned CNT network

  2. Impact of carbon nanotube length on electron transport in aligned carbon nanotube networks

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeonyoon; Stein, Itai Y. [Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, Massachusetts 02139 (United States); Devoe, Mackenzie E. [Department of Materials Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, Massachusetts 02139 (United States); Lewis, Diana J.; Lachman, Noa; Buschhorn, Samuel T.; Wardle, Brian L., E-mail: wardle@mit.edu [Department of Aeronautics and Astronautics, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, Massachusetts 02139 (United States); Kessler, Seth S. [Metis Design Corporation, 205 Portland St., Boston, Massachusetts 02114 (United States)

    2015-02-02

    Here, we quantify the electron transport properties of aligned carbon nanotube (CNT) networks as a function of the CNT length, where the electrical conductivities may be tuned by up to 10× with anisotropies exceeding 40%. Testing at elevated temperatures demonstrates that the aligned CNT networks have a negative temperature coefficient of resistance, and application of the fluctuation induced tunneling model leads to an activation energy of ≈14 meV for electron tunneling at the CNT-CNT junctions. Since the tunneling activation energy is shown to be independent of both CNT length and orientation, the variation in electron transport is attributed to the number of CNT-CNT junctions an electron must tunnel through during its percolated path, which is proportional to the morphology of the aligned CNT network.

  3. Short uncemented stems allow greater femoral flexibility and may reduce peri-prosthetic fracture risk: a dry bone and cadaveric study.

    Science.gov (United States)

    Jones, Christopher; Aqil, Adeel; Clarke, Susannah; Cobb, Justin P

    2015-09-01

    Short femoral stems for uncemented total hip arthroplasty have been introduced as a safe alternative to traditional longer stem designs. However, there has been little biomechanical examination of the effects of stem length on complications of surgery. This study aims to examine the effect of femoral stem length on torsional resistance to peri-prosthetic fracture. We tested 16 synthetic and two paired cadaveric femora. Specimens were implanted and then rapidly rotated until fracture to simulate internal rotation on a planted foot, as might occur during stumbling. 3D planning software and custom-printed 3D cutting guides were used to enhance the accuracy and consistency of our stem insertion technique. Synthetic femora implanted with short stems fractured at a significantly higher torque (27.1 vs. 24.2 Nm, p = 0.03) and angle (30.3° vs. 22.3°, p = 0.002) than those implanted with long stems. Fracture patterns of the two groups were different, but showed remarkable consistency within each group. These characteristic fracture patterns were closely replicated in the pair of cadaveric femora. This new short-stemmed press-fit femoral component allows more femoral flexibility and confers a higher resistance to peri-prosthetic fracture from torsional forces than long stems.

  4. Scaling analysis of the non-Abelian quasiparticle tunneling in [Formula: see text] FQH states.

    Science.gov (United States)

    Li, Qi; Jiang, Na; Wan, Xin; Hu, Zi-Xiang

    2018-06-27

    Quasiparticle tunneling between two counter propagating edges through point contacts could provide information on its statistics. Previous study of the short distance tunneling displays a scaling behavior, especially in the conformal limit with zero tunneling distance. The scaling exponents for the non-Abelian quasiparticle tunneling exhibit some non-trivial behaviors. In this work, we revisit the quasiparticle tunneling amplitudes and their scaling behavior in a full range of the tunneling distance by putting the electrons on the surface of a cylinder. The edge-edge distance can be smoothly tuned by varying the aspect ratio for a finite size cylinder. We analyze the scaling behavior of the quasiparticles for the Read-Rezayi [Formula: see text] states for [Formula: see text] and 4 both in the short and long tunneling distance region. The finite size scaling analysis automatically gives us a critical length scale where the anomalous correction appears. We demonstrate this length scale is related to the size of the quasiparticle at which the backscattering between two counter propagating edges starts to be significant.

  5. Studies of proximity-effect and tunneling in YBCO/metal layered films

    Energy Technology Data Exchange (ETDEWEB)

    Greene, L.H.; Barner, J.B.; Feldmann, W.L.; Farrow, L.A.; Miceli, P.F.; Ramesh, R.; Wilkens, B.J.; Bagley, B.G.; Tarascon, J.M.; Wernick, J.H. (Bellcore, Red Bank, NJ (USA)); Giroud, M. (CRTBT-CNRS, Grenoble (France)); Rowell, J.M. (Conductus, Sunnyvale, CA (USA))

    1989-12-01

    The short coherence length of the high-Tc superconductors, coupled with their tendency to form non-superconducting surface layers, accounts for the difficulty in achieving good tunnel junctions. A proximity layer of a longer coherence length normal metal (N) is expected to ''draw out'' Cooper pairs. Our goal is to fabricate reproducible, planar tunnel junctions of SNIS layered structures for proximity tunneling spectroscopy. Such structures of YBCO/N/I/Pb and SNS structures of YBCO/N/Pb indicate that the normal metal produces a low resistance contact to the YBCO surface with a supercurrent observed in the SNS. The insulating barrier in the SNIS is reproducible, insulating and continuous: A sharp Pb gap and phonons from the counter-electrode are routinely observed. (orig.).

  6. Studies of proximity-effect and tunneling in YBCO/metal layered films

    International Nuclear Information System (INIS)

    Greene, L.H.; Barner, J.B.; Feldmann, W.L.; Farrow, L.A.; Miceli, P.F.; Ramesh, R.; Wilkens, B.J.; Bagley, B.G.; Tarascon, J.M.; Wernick, J.H.; Giroud, M.; Rowell, J.M.

    1989-01-01

    The short coherence length of the high-T c superconductors, coupled with their tendency to form non-superconducting surface layers, accounts for the difficulty in achieving good tunnel junctions. A proximity layer of a longer coherence length normal metal (N) is expected to draw out Cooper pairs. The authors' goal is to fabricate reproducible, planar tunnel junctions of SNIS layered structures for proximity tunneling spectroscopy. They discuss how such structures of YBCO/N/I/Pb and SNS structures of YBCO/N/Pb indicate that the normal metal produces a low resistance contact to the YBCO surface with a supercurrent observed in the SNS. The insulating barrier in the SNIS is reproducible, insulating and continuous: A sharp Pb gap and phonons from the counter-electrode are routinely observed

  7. The tridimensional geometry of the proximal femur should determine the design of cementless femoral stem in total hip arthroplasty.

    Science.gov (United States)

    Wegrzyn, Julien; Roux, Jean-Paul; Loriau, Charlotte; Bonin, Nicolas; Pibarot, Vincent

    2018-02-22

    Using a cementless femoral stem in total hip arthroplasty (THA), optimal filling of the proximal femoral metaphyseal volume (PFMV) and restoration of the extramedullary proximal femoral (PF) parameters (i.e., femoral offset (FO), neck length (FNL), and head height (FHH)) constitute key goals for optimal hip biomechanics, functional outcome, and THA survivorship. However, almost 30% of mismatch between the PF anatomy and implant geometry of the most widely implanted non-modular cementless femoral stem has been demonstrated in a computed tomography scan (CT scan) study. Therefore, this anatomic study aimed to evaluate the relationship between the intra- and extramedullary PF parameters using tridimensional CT scan reconstructions. One hundred fifty-one CT scans of adult healthy hips were obtained from 151 male Caucasian patients (mean age = 66 ± 11 years) undergoing lower limb CT scan arteriography. Tridimensional PF reconstructions and parameter measurements were performed using a corrected PF coronal plane-defined by the femoral neck and diaphyseal canal longitudinal axes-to avoid influence of PF helitorsion and femoral neck version on extramedullary PF parameters. Independently of the femoral neck-shaft angle, the PFMV was significantly and positively correlated with the FO, FNL, and FHH (r = 0.407 to 0.420; p < 0.0001). This study emphasized that the tridimensional PF geometry measurement in the corrected coronal plane of the femoral neck can be useful to determine and optimize the design of a non-modular cementless femoral stem. Particularly, continuous homothetic size progression of the intra- and extramedullary PF parameters should be achieved to assure stem fixation and restore anatomic hip biomechanics.

  8. Electric and VLF-MT survey of Tegatayama tunnel; Tegatayama tunnel no denki tansa oyobi VLF tansa

    Energy Technology Data Exchange (ETDEWEB)

    Nishitani, T [Akita University, Akita (Japan). Mining College

    1997-05-27

    To survey the structure at the depth between 20 and 30 m, field tests were conducted by means of vertical electric and VFL-MT (magnetotelluric) survey. Tegatayama tunnel has a total length of 276 m, width of 7.5 m, and height of 4.7 m, and the depth from the surface is about 28 m near the top of mountain. Near the tunnel, the thickness of surface soil is about 60 cm, which consists of clay soil including soft mudstone gravel. It was found that terrace deposit is distributed up to the depth of 8 m, and that mudstone is distributed below the depth of 8 m. Weighted four-electrode method was adopted for the vertical electrical survey. Measurements were conducted at the immediately above the tunnel, 10 m apart from the center of tunnel in the right and left, and 20 m apart from the center in the east. For the VLF-MT method, component of frequency 22.2 kHz was used. As a result of the tests, it was difficult to illustrate the existence of tunnel from the vertical electrical survey only at one point. Feature of the tunnel could be well illustrated by means of the VLF-MT method. 3 refs., 9 figs.

  9. Varus femoral osteotomy improves sphericity of the femoral head in older children with severe form of Legg-Calvé-Perthes disease.

    Science.gov (United States)

    Terjesen, Terje; Wiig, Ola; Svenningsen, Svein

    2012-09-01

    In the Norwegian prospective study on Legg-Calvé-Perthes disease (LCPD), we found varus femoral osteotomy gave better femoral head sphericity at a mean of 5 years postoperative than physiotherapy in children older than 6.0 years at diagnosis with femoral head necrosis of more than 50%. That study did not include separate analyses for hips with 100% necrosis and those with a percentage of necrosis between 50% and 100%. We asked whether (1) femoral osteotomy improves femoral head sphericity at followup in all patients with more than 50% femoral head necrosis or in selected groups only and (2) there is a critical age between 6.0 and 10.0 years over which femoral osteotomy does not improve the prognosis. We treated 70 patients with unilateral LCPD, age at diagnosis of more than 6.0 years, and femoral head necrosis of more than 50% with varus femoral osteotomy between 1996 and 2000. We classified necrosis using the Catterall classification. We established a control group of 51 similar children who received physiotherapy. At the 5-year followup visit, the hips were graded according to femoral head shape: spherical, ovoid, or flat. At 5-year followup, there was no difference between the treatment groups in radiographic outcome in Catterall Group 3 hips. In Catterall Group 4 hips, femoral head sphericity was better in the osteotomy group, with flat femoral heads in 14% compared to 75% after physiotherapy. The same trend toward better head sphericity occurred when the lateral pillar classification was used. In children aged 6.0 to 10.0 years, in whom the whole femoral head is affected, femoral head sphericity 5 years after femoral osteotomy was better than that after physiotherapy.

  10. Oscillations in a Forward-Facing Cavity Measured Using Laser-Differential Interferometry in a Hypersonic Quiet Tunnel

    Science.gov (United States)

    2007-12-11

    Boeing/AFOSR Mach-6 Quiet Tunnel BFL Back Focal Length xvi CCA Constant Current Anemometer EFL Effective Focal Length FFC Forward Facing Cavity LDI Laser...step in the nozzle throat. This tunnel is currently used for teaching as well as for research. Some years ago, a group of students separated the

  11. Management of complex femoral nonunion with monorail external fixator: A prospective study.

    Science.gov (United States)

    Agrawal, Hemendra Kumar; Garg, Mohit; Singh, Balvinder; Jaiman, Ashish; Khatkar, Vipin; Khare, Shailender; Batra, Sumit; Sharma, Vinod Kumar

    2016-01-01

    To evaluate 30 patients who underwent distraction osteogenesis with monorail external fixator for complex femoral nonunion. Complex femoral nonunion includes infective non-union, gap nonunion, and limb-length discrepancy secondary to traumatic bone loss, which needs specialized treatment to ensure the functional integrity of femoral bone. 30 patients, including 28 male and 2 female (aged 22-62 years) patients, underwent surgical debridement followed by bone transport with monorail fixator. The lengthening index, radiographic consolidation index, functional status, bone healing, and various problems, obstacles, and complications encountered during the treatment were assessed. Patients underwent a mean of 2.2 (range 1-4) surgeries before presentation. The mean bone defect after surgical debridement was 5.83 cm (range 2-16 cm). The mean treatment duration was 204.7 days (range 113-543 days). The mean lengthening index was 13.06 days/cm with range from 12 to 16 days/cm. Mean maturation index was 23.51 days/cm with range from 17 to 45.5 days/cm. In our study, bone result was excellent in 17, good in 9, fair in 3, and poor in 1 patient. In our study functional outcome is excellent in 9 [30%], good in 14 [46.67%], fair in 5, and poor in 2 patients. In our study, we encountered 34 problems, 17 obstacles, and 8 complications. We concluded that monorail external fixator is an effective treatment option for complex nonunion femoral shaft fracture and its functional outcome is comparable with any other treatment options. Lack of complications and its effectiveness makes monorail external fixator the treatment of choice for complex nonunion femoral shaft.

  12. Preoperative virtual reduction reduces femoral malrotation in the treatment of bilateral femoral shaft fractures.

    Science.gov (United States)

    Omar, Mohamed; Suero, Eduardo M; Hawi, Nael; Decker, Sebastian; Krettek, Christian; Citak, Musa

    2015-10-01

    In bilateral femoral shaft fractures, significant malrotation (>15°) occurs in about 40 % of cases after intramedullary nailing. Most of the methods that provide rotational control during surgery are based on a comparison to the intact femur and, thus, not applicable for bilateral fractures. In this study, we evaluated if preoperative virtual reduction can help improving rotational alignment in patients with bilateral femoral shaft fractures. Seven patients with bilateral femoral shaft fractures were initially treated with external fixation of both femurs. After obtaining a CT scan of both legs, the fractures were reduced virtually using the software program VoXim®, and the amount and direction of rotational correction were calculated. Subsequently, the patients were treated by antegrade femoral nailing and rotation was corrected to the preoperatively calculated amount. After external fixation, the mean rotational difference between both legs was 15.0° ± 10.2°. Four out of seven patients had a significant malrotation over 15°. Following virtual reduction, the mean rotational difference between both legs was 2.1° ± 1.2°. After intramedullary nailing, no case of malrotation occurred and the mean rotational difference was 6.1° ± 2.8°. Preoperative virtual reduction allows determining the pretraumatic femoral antetorsion and provided useful information for the definitive treatment of bilateral femoral shaft fractures. We believe that this procedure is worth being implemented in the clinical workflow to avoid malrotation after intramedullary nailing.

  13. [Trochanteric femoral fractures].

    Science.gov (United States)

    Douša, P; Čech, O; Weissinger, M; Džupa, V

    2013-01-01

    At the present time proximal femoral fractures account for 30% of all fractures referred to hospitals for treatment. Our population is ageing, the proportion of patients with post-menopausal or senile osteoporosis is increasing and therefore the number of proximal femoral fractures requiring urgent treatment is growing too. In the age category of 50 years and older, the incidence of these fractures has increased exponentially. Our department serves as a trauma centre for half of Prague and part of the Central Bohemia Region with a population of 1 150 000. Prague in particular has a high number of elderly citizens. Our experience is based on extensive clinical data obtained from the Register of Proximal Femoral Fractures established in 1997. During 14 years, 4280 patients, 3112 women and 1168 men, were admitted to our department for treatment of proximal femoral fractures. All patients were followed up until healing or development of complications. In the group under study, 82% were patients older than 70 years; 72% of those requiring surgery were in their seventies and eighties. Men were significantly younger than women (pfractures were 2.3-times more frequent in women than in men. In the category under 60 years, men significantly outnumbered women (pfractures were, on the average, eight years older than the patients with intertrochanteric fractures, which is a significant difference (pTrochanteric fractures accounted for 54.7% and femoral neck fractures for 45.3% of all fractures. The inter-annual increase was 5.9%, with more trochanteric than femoral neck fractures. There was a non-significant decrease in intertrochanteric (AO 31-A3) fractures. On the other hand, the number of pertrochanteric (AO 31-A1+2) fractures increased significantly (pfractures were treated with a proximal femoral nail; a short nail was used in 1260 and a long nail in 134 of them. A dynamic hip screw (DHS) was employed to treat 947 fractures. Distinguishing between pertrochanteric (21-A1

  14. On the flow of groundwater in closed tunnels. Generic hydrogeological modelling of nuclear waste repository, SFL 3-5

    International Nuclear Information System (INIS)

    Holmen, J.G.

    1997-06-01

    The purpose is to study the flow of groundwater in closed tunnels by use of mathematical models. The calculations were based on three dimensional models, presuming steady state conditions. The stochastic continuum approach was used for representation of a heterogeneous rock mass. The size of the calculated flow is given as a multiple of an unknown regional groundwater flow. The size of the flow in a tunnel has been studied, as regards: Direction of the regional groundwater flow, Tunnel length, width and conductivity; Heterogeneity of the surrounding rock mass; Flow barriers and encapsulation inside a tunnel. The study includes a model of the planned repository for nuclear waste (SFL 3-5). The flow through the tunnels is estimated for different scenarios. The stochastic continuum approach has been investigated, as regards the representation of a scale dependent heterogeneous conductivity. An analytical method is proposed for the scaling of measured conductivity values, the method is consistent with the stochastic continuum approach. Some general conclusions from the work are: The larger the amount of heterogeneity, the larger the expected flow; The effects of the heterogeneity will decrease with increased tunnel length; If the conductivity of the tunnel is smaller than a threshold value, the tunnel conductivity is the most important parameter; If the tunnel conductivity is large and the tunnel is long, the most important parameter is the direction of the regional flow; Given a heterogeneous rock mass, if the tunnel length is shorter than about 500 m, the heterogeneity will be an important parameter, for lengths shorter than about 250 m, probably the most important; The flow through an encapsulation surrounded by a flow barrier is mainly dependent on the conductivity of the barrier. 70 refs, 110 figs, 10 tabs

  15. On the flow of groundwater in closed tunnels. Generic hydrogeological modelling of nuclear waste repository, SFL 3-5

    Energy Technology Data Exchange (ETDEWEB)

    Holmen, J.G. [Uppsala Univ. (Sweden). Inst. of Earth Sciences]|[Golder Associates AB (Sweden)

    1997-06-01

    The purpose is to study the flow of groundwater in closed tunnels by use of mathematical models. The calculations were based on three dimensional models, presuming steady state conditions. The stochastic continuum approach was used for representation of a heterogeneous rock mass. The size of the calculated flow is given as a multiple of an unknown regional groundwater flow. The size of the flow in a tunnel has been studied, as regards: Direction of the regional groundwater flow, Tunnel length, width and conductivity; Heterogeneity of the surrounding rock mass; Flow barriers and encapsulation inside a tunnel. The study includes a model of the planned repository for nuclear waste (SFL 3-5). The flow through the tunnels is estimated for different scenarios. The stochastic continuum approach has been investigated, as regards the representation of a scale dependent heterogeneous conductivity. An analytical method is proposed for the scaling of measured conductivity values, the method is consistent with the stochastic continuum approach. Some general conclusions from the work are: The larger the amount of heterogeneity, the larger the expected flow; The effects of the heterogeneity will decrease with increased tunnel length; If the conductivity of the tunnel is smaller than a threshold value, the tunnel conductivity is the most important parameter; If the tunnel conductivity is large and the tunnel is long, the most important parameter is the direction of the regional flow; Given a heterogeneous rock mass, if the tunnel length is shorter than about 500 m, the heterogeneity will be an important parameter, for lengths shorter than about 250 m, probably the most important; The flow through an encapsulation surrounded by a flow barrier is mainly dependent on the conductivity of the barrier. 70 refs, 110 figs, 10 tabs.

  16. Numerical analysis of the slipstream development around a high-speed train in a double-track tunnel.

    Science.gov (United States)

    Fu, Min; Li, Peng; Liang, Xi-Feng

    2017-01-01

    Analysis of the slipstream development around the high-speed trains in tunnels would provide references for assessing the transient gust loads on trackside workers and trackside furniture in tunnels. This paper focuses on the computational analysis of the slipstream caused by high-speed trains passing through double-track tunnels with a cross-sectional area of 100 m2. Three-dimensional unsteady compressible Reynolds-averaged Navier-Stokes equations and a realizable k-ε turbulence model were used to describe the airflow characteristics around a high-speed train in the tunnel. The moving boundary problem was treated using the sliding mesh technology. Three cases were simulated in this paper, including two tunnel lengths and two different configurations of the train. The train speed in these three cases was 250 km/h. The accuracy of the numerical method was validated by the experimental data from full-scale tests, and reasonable consistency was obtained. The results show that the flow field around the high-speed trains can be divided into three distinct regions: the region in front of the train nose, the annular region and the wake region. The slipstream development along the two sides of train is not in balance and offsets to the narrow side in the double-track tunnels. Due to the piston effect, the slipstream has a larger peak value in the tunnel than in open air. The tunnel length, train length and length ratio affect the slipstream velocities; in particular, the velocities increase with longer trains. Moreover, the propagation of pressure waves also induces the slipstream fluctuations: substantial velocity fluctuations mainly occur in front of the train, and weaken with the decrease in amplitude of the pressure wave.

  17. Recent development in the design of hard rock tunnel boring machines for the mining industry

    International Nuclear Information System (INIS)

    Snyder, L.L.; Williams, R.I.

    1991-01-01

    Underground development for nuclear waste storage will possibly require tunnels to be excavated in a variety of rock conditions and configurations. Recent innovations in Tunnel Boring Machine (TBM) design have allowed for an evolved style of TBM which has distinct advantages over the standard machines. Present day conventional hard rock TBM's were developed primarily for the long, relatively straight tunnels of the civil construction industry, thereby making them for the most part, unsuitable for the sharp curves, turnouts, declines, inclines and ramps required in many underground environments. The five foot to 36 foot (1.52 to 11 m) diameter machines are capable of boring tunnels with curve radiuses as small as 40 to 90 feet (12.2 to 27.5 m) depending on size. These short turning radiuses can be accomplished while gripping the tunnel walls horizontally in the traditional manner or vertically as required when intersecting existing tunnels, or making turnouts from the tunnel that the machine has just bored. The machine's length is approximately half of a traditional machine's length while still employing a full measure of thrust, horsepower and rock cutting ability. The machine's short length, combined with a patented machine structure allows it to steer while boring without causing harmful eccentric loads on the cutterhead and main bearing assembly. The machine configuration is versatile and can be easily modified to operate in a wide variety of conditions

  18. Atrophic femoral nonunion with bone loss: treatment with monorail transport: a case report.

    Science.gov (United States)

    Gay, David M; Voss, Frank R

    2004-08-01

    Nonunions are an uncommon outcome of femoral fractures. Atrophic nonunions with a leg length discrepancy secondary to bone loss are often the most difficult to treat, and the treatment options are limited. We present a case that uses concomitant monolateral external fixation and intramedullary nailing to heal a nonunion and perform a simultaneous 7-cm lengthening procedure in a 33-year-old female.

  19. Ultrasound-Guided Femoral Nerve Block to Facilitate the Closed Reduction of a Dislocated Hip Prosthesis

    Directory of Open Access Journals (Sweden)

    Edward Carlin

    2017-10-01

    Full Text Available Prosthetic hip dislocation is a common but unfortunate complication in patients who have undergone total hip arthroplasty. Successful closed reduction in the emergency department leads to a reduced length of stay and rate of hospitalization. 1, 2 The use of regional anesthesia by femoral nerve block represents a novel approach for controlling pain in patients with hip pathologies. 3 Ultrasound-guided approaches have been used with great success for controlling pain in patients with hip fractures. 4, 5 Here we report the case of a 90-year-old male who presented with a dislocated hip prosthesis, which was subsequently corrected with closed reduction following delivery of regional anesthesia to the femoral nerve under ultrasound guidance. To our knowledge, this represents the first reported use of an ultrasound-guided femoral nerve block to facilitate closed reduction of a dislocated prosthetic hip, and highlights a novel approach that avoids the use of procedural sedation in an elderly patient.

  20. To study the role of dynamic magnetic resonance imaging in assessing the femoral head vascularity in intracapsular femoral neck fractures

    Energy Technology Data Exchange (ETDEWEB)

    Kaushik, Abhishek, E-mail: abhiortho27@gmail.co [Department of Orthopedics, 513, Thermal Colony, Sector-22, Faridabad 121005, Haryana (India); Sankaran, Balu; Varghese, Mathew [Department of Orthopedics, St Stephen' s Hospital, Tis hazari, Delhi, New Delhi 110054 (India)

    2010-09-15

    Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in predicting vascularity after femoral neck fracture are 87%, 88% and 87%, respectively. Type A or Type B curve pattern is a positive factor to successful osteosynthesis with p value <0.0001 (Chi-square test). This is a statistically significant value. From this finding it can be suggested that the reliability of dynamic curves A and B in predicting maintained vascularity of femoral head is high. This investigation can be used to predict the vascularity of femoral head after intracapsular femoral neck fractures. There was a good correlation between the outcomes of fractures and dynamic MRI curves done within 48 h of injury. This signifies the role of dynamic MRI in predicting the vascularity of femoral head as early as 48 h. A treatment algorithm can be suggested on the basis of dynamic MRI curves. The fractures with Type C dynamic curve should be considered as fractures with poor vascularity of femoral head and measures to enhance the vascularity of femoral head along with rigid internal fixation should be undertaken to promote

  1. To study the role of dynamic magnetic resonance imaging in assessing the femoral head vascularity in intracapsular femoral neck fractures

    International Nuclear Information System (INIS)

    Kaushik, Abhishek; Sankaran, Balu; Varghese, Mathew

    2010-01-01

    Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in predicting vascularity after femoral neck fracture are 87%, 88% and 87%, respectively. Type A or Type B curve pattern is a positive factor to successful osteosynthesis with p value <0.0001 (Chi-square test). This is a statistically significant value. From this finding it can be suggested that the reliability of dynamic curves A and B in predicting maintained vascularity of femoral head is high. This investigation can be used to predict the vascularity of femoral head after intracapsular femoral neck fractures. There was a good correlation between the outcomes of fractures and dynamic MRI curves done within 48 h of injury. This signifies the role of dynamic MRI in predicting the vascularity of femoral head as early as 48 h. A treatment algorithm can be suggested on the basis of dynamic MRI curves. The fractures with Type C dynamic curve should be considered as fractures with poor vascularity of femoral head and measures to enhance the vascularity of femoral head along with rigid internal fixation should be undertaken to promote

  2. Profunda Anchor Technique for Ipsilateral Antegrade Approach in Endovascular Treatment of Superficial Femoral Artery Ostial Occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2015-04-15

    Endovascular treatment of the superficial femoral artery (SFA) is challenging in the presence of flush ostial occlusion. One of the main challenges is the availability of access sites for intervention. Contralateral retrograde femoral access followed by cross-over and antegrade intervention while commonly used, may not be feasible in cases of altered iliac anatomy (e.g. kissing iliac stents). Ipsilateral antegrade intervention using common femoral artery (CFA) access in these instances while possible is typically challenging due to inadequate working length of the CFA for interrogation of the SFA ostium, compounded by the lack of sheath stability. The “profunda anchor” technique uses a buddy wire in the profunda femoris artery (PFA) to stabilize the sheath and allow catheter manipulation for antegrade intervention at the level of the SFA ostium. The PFA is further used as a conduit for deployment of closure device to avoid interference with the treated SFA.

  3. Profunda Anchor Technique for Ipsilateral Antegrade Approach in Endovascular Treatment of Superficial Femoral Artery Ostial Occlusion

    International Nuclear Information System (INIS)

    Pua, Uei

    2015-01-01

    Endovascular treatment of the superficial femoral artery (SFA) is challenging in the presence of flush ostial occlusion. One of the main challenges is the availability of access sites for intervention. Contralateral retrograde femoral access followed by cross-over and antegrade intervention while commonly used, may not be feasible in cases of altered iliac anatomy (e.g. kissing iliac stents). Ipsilateral antegrade intervention using common femoral artery (CFA) access in these instances while possible is typically challenging due to inadequate working length of the CFA for interrogation of the SFA ostium, compounded by the lack of sheath stability. The “profunda anchor” technique uses a buddy wire in the profunda femoris artery (PFA) to stabilize the sheath and allow catheter manipulation for antegrade intervention at the level of the SFA ostium. The PFA is further used as a conduit for deployment of closure device to avoid interference with the treated SFA

  4. Femoral head avascular necrosis

    International Nuclear Information System (INIS)

    Chrysikopoulos, H.; Sartoris, D.J.; Resnick, D.L.; Ashburn, W.; Pretorius, T.

    1988-01-01

    MR imaging has been shown to be more sensitive and specific than planar scintigraphy for avascular necrosis (AVN) of the femoral head. However, experience with single photon emission CT (SPECT) is limited. The authors retrospectively compared 1.5-T MR imaging with SPECT in 14 patients with suspected femoral head AVN. Agreement between MR imaging and SPECT was present in 24 femurs, 14 normal and ten with AVN. MR imaging showed changes of AVN in the remaining four femoral heads. Of these, one was normal and the other three inconclusive for AVN by SPECT. The authors conclude that MR imaging is superior to SPECT for the evaluation of AVN of the hip

  5. Femoral revision with impaction allografting and an uncemented femoral component

    DEFF Research Database (Denmark)

    Nickelsen, T N; Erenbjerg, M; Retpen, J B

    2008-01-01

    A technique for uncemented revision of the femoral component which combines impaction allografting and the use of a long-stemmed proximally coated titanium prostheses (Bimetric, Biomet Inc.) is described. The results after a mean follow-up of 112 months are reported. From 1991 to 1995 femoral...... implants 88% had no pain, 10% had slight pain and only 2% had severe pain. Thirty-eight patients had radiographic signs of remodelling of the graft and/or cortical repair. In cases with a successful outcome, the results have been encouraging in relation to clinical performance, regeneration of bone...

  6. Laboratory Study of the Influence of Substrate Type and Temperature on the Exploratory Tunneling by Formosan Subterranean Termite

    Directory of Open Access Journals (Sweden)

    Bal K. Gautam

    2012-06-01

    Full Text Available Using two-dimensional foraging arenas, laboratory tests were conducted to investigate the effect of soil type, soil moisture level and ambient temperature on the exploratory tunneling by Coptotermes formosanus Shiraki. In choice arenas consisting of two substrate types having two moisture levels each, and conducted at a constant temperature of 22 °C, a significantly greater proportion of termites aggregated in sand than in sandy loam. Similarly, the length of excavated tunnels was also increased in sand. In a given substrate, termite aggregation or tunnel length did not differ between 5% and 15% moisture levels. In no-choice tests, where three different substrates (sand, sandy loam and silt loam were tested at two temperatures (22 °C and 28 °C, excavations were significantly greater in sand than either sandy loam or silt loam at 22 °C. Fewer primary tunnels were constructed in sandy loam than in sand and fewer branched tunnels than either in sand or silt loam. No significant difference in either tunnel length or number of primary or branched tunnels was found between these two temperatures.

  7. COMPARATIVE STUDY OF ARTHROSCOPIC SINGLE BUNDLE ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION AND NON-ANATOMICAL DOUBLE BUNDLE WITH SINGLE TIBIAL TUNNEL ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION WITH SEMITENDINOSUS ± GRACILIS AUTOGRAFTS USING LAXOMETRY

    Directory of Open Access Journals (Sweden)

    Sivananda

    2016-01-01

    Full Text Available BACKGROUND The knee joint is the most commonly injured of all joints and the ACL is the most commonly injured ligament. Arthroscopic reconstruction of ACL has become gold standard in treating these injuries. AIM 1. To compare the short-term results of ACL reconstruction using single bundle (one Tibial + one Femoral tunnel and non-anatomical double-bundle (one Tibial + two Femoral tunnels techniques using Hamstrings (Semitendinosus ± Gracilis graft. 2. To evaluate ACL graft reconstruction stability measured by laxometry and to find out an association with clinical findings. MATERIAL & METHODS We performed a prospective study between 2014-2015 of 20 case of ACL injuries & compared single bundle reconstruction with Non – anatomical double Bundle reconstruction with semitendinosus ± Gracilis, Autograft using laxometry. CONCLUSION Arthroscopic Non-anatomical double ACL Reconstruction is Bio-mechanically stable reconstruction resembling anatomy of the ACL.

  8. [Ex vivo microCT analysis of possible microfractures of the femoral head during implantation of a cementless hip resurfacing femoral component].

    Science.gov (United States)

    Lerch, M; Olender, G; von der Höh, N; Thorey, F; von Lewinski, G; Meyer-Lindenberg, A; Windhagen, H; Hurschler, C

    2009-01-01

    Microfractures of the femoral head during implantation of the femoral components are suspected to be a cause of fractures at the implant/neck junction which represent a common failure mode in hip resurfacing arthroplasty. Callus formation observed in femoral head retrievals suggests the occurrence of microfractures inside the femoral head, which might be inadvertently caused by the surgeon during implantation. The aim of this biomechanical study was to analyse whether or not the implantation of a cementless femoral component hip resurfacing system causes microfractures in the femoral head. After the preparation of 20 paired human cadaveric femoral heads, the cementless femoral component ESKA Typ BS (ESKA Implants GmbH & Co., Lübeck) was implanted on 9 specimens with an impaction device that generates 4.5 kN impaction force. On 9 specimens the femoral component was implanted by hand. One head was used as a fracture model, 1 specimen served as control without manipulation. The femoral component used for impaction was equipped with hinges to enable its removal without further interfering with the bone stock. Specimens were scanned with a microCT device before and after impaction and the microCT datasets before and after impaction were compared to identify possible microfractures. Twenty strikes per hand or with the impaction device provided sufficient implant seating. Neither the macroscopic examination nor the 2-dimensional microCT analysis revealed any fractures of the femoral heads after impaction. At least macroscopically and in the 2-dimensional microCT analysis, implantation of the cementless hip resurfacing femoral component ESKA Typ BS with 4.5 kN or by hand does not seem to cause fractures of the femoral head. Georg Thieme Verlag KG Stuttgart, New York.

  9. A Morphological Insight of the Femoral Vein

    Directory of Open Access Journals (Sweden)

    Ferreira AH

    2015-10-01

    Full Text Available A total of 13 cadavers (12 men and 1 women of different age group were used for the study with the purpose to determine the prevalence of femoral vein duplication. Lower limb regions (26 sides were carefully dissected as per the standard dissection procedure. Femoral vein (unitruncular was found in 96.15% of specimen. Bitruncular configurations (total bifidity was found in a male cadaver of 75 years of age (3.85%. In the right lower limb, 6.5 cms below the inguinal ligament the femoral vein - lateral ramus received the lateral circumflex femoral vein, and the medial circumflex femoral vein, and the lateral and medial ramii formed a common venous trunk. Knowledge of the truncular venous variations is important to recognize and avoid potential errors in diagnosis of deep venous thrombosis of the femoral vein, in the case of an occluded duplicated trunk.

  10. Tunnel magnetoresistance in alumina, magnesia and composite tunnel barrier magnetic tunnel junctions

    International Nuclear Information System (INIS)

    Schebaum, Oliver; Drewello, Volker; Auge, Alexander; Reiss, Guenter; Muenzenberg, Markus; Schuhmann, Henning; Seibt, Michael; Thomas, Andy

    2011-01-01

    Using magnetron sputtering, we have prepared Co-Fe-B/tunnel barrier/Co-Fe-B magnetic tunnel junctions with tunnel barriers consisting of alumina, magnesia, and magnesia-alumina bilayer systems. The highest tunnel magnetoresistance ratios we found were 73% for alumina and 323% for magnesia-based tunnel junctions. Additionally, tunnel junctions with a unified layer stack were prepared for the three different barriers. In these systems, the tunnel magnetoresistance ratios at optimum annealing temperatures were found to be 65% for alumina, 173% for magnesia, and 78% for the composite tunnel barriers. The similar tunnel magnetoresistance ratios of the tunnel junctions containing alumina provide evidence that coherent tunneling is suppressed by the alumina layer in the composite tunnel barrier. - Research highlights: → Transport properties of Co-Fe-B/tunnel barrier/Co-Fe-B magnetic tunnel junctions. → Tunnel barrier consists of MgO, Al-Ox, or MgO/Al-Ox bilayer systems. → Limitation of TMR-ratio in composite barrier tunnel junctions to Al-Ox values. → Limitation indicates that Al-Ox layer is causing incoherent tunneling.

  11. Fine structures on zero-field steps in low-loss Josephson tunnel junctions

    DEFF Research Database (Denmark)

    Monaco, Roberto; Barbara, Paola; Mygind, Jesper

    1993-01-01

    The first zero-field step in the current-voltage characteristic of intermediate-length, high-quality, low-loss Nb/Al-AlOx/Nb Josephson tunnel junctions has been carefully investigated as a function of temperature. When decreasing the temperature, a number of structures develop in the form...... of regular and slightly hysteretic steps whose voltage position depends on the junction temperature and length. This phenomenon is interesting for the study of nonlinear dynamics and for application of long Josephson tunnel junctions as microwave and millimeter-wavelength oscillators....

  12. Analysis Of Resistance And Effective Wake Friction Due To Addition Of Stern Tunnels On Passenger Ship Using Cfd

    Science.gov (United States)

    Chrismianto, D.; Tuswan; Manik, P.

    2018-03-01

    In this study, the stern tunnel to improve the efficiency of ship propulsion system is analysed. Stern tunnels installed on the two sides of the ship stern. Analysis of ship resistance and wake friction of the ship using CFD are carried out. The stern tunnel height (Hw) and length (L) are implemented to find the better stern tunnel form of the ship. The result of analysis showed that model has a high stern tunnels (Hw) of 1,444 m or additional high stern tunnels ratio of 16% and stern long tunnels (L) about 7 m is a model that has the smallest resistance about 1.1137 N or able to make reduction of resistance amount 11.2582%. While, the model with the addition of height of 0.2 m and a length of 9 m of stern tunnel is a model that has the better advanced speed about 4,927% in increase, and better wake friction about 30.4% in reduce.

  13. Small-scale tunnel test for blast performance

    International Nuclear Information System (INIS)

    Felts, J E; Lee, R J

    2014-01-01

    The data reported here provide a validation of a small-scale tunnel test as a tool to guide the optimization of new explosives for blast performance in tunnels. The small-scale arrangement consisted of a 2-g booster and 10-g sample mounted at the closed end of a 127 mm diameter by 4.6-m long steel tube with pressure transducers along its length. The three performance characteristics considered were peak pressure, initial energy release, and impulse. The relative performance from five explosives was compared to that from a 1.16-m diameter by 30-m long tunnel that used 2.27-kg samples. The peak pressure values didn't correlate between the tunnels. Partial impulse for the explosives did rank similarly. The initial energy release was determined from a one-dimensional point-source analysis, which nearly tracked with impulse suggesting additional energy released further down the tunnel for some explosives. This test is a viable tool for optimizing compositional variations for blast performance in target scenarios of similar geometry.

  14. Subtrochanteric Femoral Fracture during Trochanteric Nailing for the Treatment of Femoral Shaft Fracture

    OpenAIRE

    Yun, Ho Hyun; Oh, Chi Hun; Yi, Ju Won

    2013-01-01

    We report on three cases of subtrochanteric femoral fractures during trochanteric intramedullary nailing for the treatment of femoral shaft fractures. Trochanteric intramedullary nails, which have a proximal lateral bend, are specifically designed for trochanteric insertion. When combined with the modified insertion technique, trochanteric intramedullary nails reduce iatrogenic fracture comminution and varus malalignment. We herein describe technical aspects of trochanteric intramedullary nai...

  15. Trunnion Failure of the Recalled Low Friction Ion Treatment Cobalt Chromium Alloy Femoral Head.

    Science.gov (United States)

    Urish, Kenneth L; Hamlin, Brian R; Plakseychuk, Anton Y; Levison, Timothy J; Higgs, Genymphas B; Kurtz, Steven M; DiGioia, Anthony M

    2017-09-01

    Gross trunnion failure (GTF) is a rare complication in total hip arthroplasty (THA) reported across a range of manufacturers. Specific lots of the Stryker low friction ion treatment (LFIT) anatomic cobalt chromium alloy (CoCr) V40 femoral head were recalled in August 2016. In part, the recall was based out of concerns for disassociation of the femoral head from the stem and GTF. We report on 28 patients (30 implants) with either GTF (n = 18) or head-neck taper corrosion (n = 12) of the LFIT CoCr femoral head and the Accolade titanium-molybdenum-zirconium-iron alloy femoral stems. All these cases were associated with adverse local tissue reactions requiring revision of the THA. In our series, a conservative estimate of the incidence of failure was 4.7% (n = 636 total implanted) at 8.0 ± 1.4 years from the index procedure. Failures were associated with a high-offset 127° femoral stem neck angle and increased neck lengths; 43.3% (13 of 30) of the observed failures included implant sizes outside the voluntary recall (27.8% [5 of 18] of the GTF and 75.0% [8 of 12] of the taper corrosion cases). Serum cobalt and chromium levels were elevated (cobalt: 8.4 ± 7.0 μg/mL; chromium: 3.4 ± 3.3 μ/L; cobalt/chromium ratio: 3.7). The metal artifact reduction sequence magnetic resonance imaging demonstrated large cystic fluid collections typical with adverse local tissue reactions. During revision, a pseudotumor was observed in all cases. Pathology suggested a chronic inflammatory response. Impending GTF could be diagnosed based on aspiration of black synovial fluid and an oblique femoral head as compared with the neck taper on radiographs. In our series of the recalled LFIT CoCr femoral head, the risk of impending GTF or head-neck taper corrosion should be considered as a potential diagnosis in a painful LFIT femoral head and Accolade titanium-molybdenum-zirconium-iron alloy THA with unknown etiology. Almost half of the failures we observed included sizes outside of the

  16. Crossover from quantum tunneling to classical hopping of domain walls in ferromagnets

    Science.gov (United States)

    Zhou, Bin; Liang, Jiu-Qing; Pu, Fu-Cho

    2001-09-01

    In the model of quantum tunneling of domain walls in ferromagnets given by Chudnovsky et al., the crossover from quantum tunneling to classical hopping is investigated. Considering the periodical boundary condition of spatial coordinate, the type of transition depends critically on the length of ferromagnet along the Y-axis.

  17. Temperature dependence of shot noise in double barrier magnetic tunnel junctions

    Science.gov (United States)

    Niu, Jiasen; Liu, Liang; Feng, J. F.; Han, X. F.; Coey, J. M. D.; Zhang, X.-G.; Wei, Jian

    2018-03-01

    Shot noise reveals spin dependent transport properties in a magnetic tunnel junction. We report measurement of shot noise in CoFeB/MgO/CoFeB/MgO/CoFeB double barrier magnetic tunnel junctions, which shows a strong temperature dependence. The Fano factor used to characterize shot noise increases with decreasing temperature. A sequential tunneling model can be used to account for these results, in which a larger Fano factor results from larger spin relaxation length at lower temperatures.

  18. Transfracture abduction osteotomy: A solution for nonunion of femoral neck fractures

    Directory of Open Access Journals (Sweden)

    Jairamchander Pingle

    2014-01-01

    femur with or without bone graft, valgus osteotomy or hip arthroplasty. We conducted a retrospective analysis of cases of nonunion of femoral neck fracture treated by transfracture abduction osteotomy (TFAO. Materials and Methods: Over a period of 35 years (1974-2008, 30 patients with nonunion of femoral neck fractures were treated with TFAO over a period of 35 years (1974-2008, All patients were less than 50 years of age. Absence of clinical and radiological signs of union after four months was considered as nonunion. Patients more than 50 years of age were excluded from the study. Union was assessed at 6 months radiologically. Limb length was measured at six months. The mean duration of femoral neck fracture was 19 months (range 4 months 10 years. Results were analyzed in terms of radiological union at six months. Average followup was five years and six months. Results: Consistent union was noted at the followup after six months in 29 cases. One case was lost to followup after five and one-half months postoperatively. However, the fracture had united in this case at the last followup. Average shortening of the limb at six months was 1.9 cm. Average neck shaft angle was 127° (range 120-145°. Five cases went into AVN but were asymptomatic. Two cases required reoperation due to back out of Moore′s pins. These were reopened and cancellous screws were inserted in the same tracks. Conclusions: Consistent union of nonunion femoral neck fracture was noted at the followup after six months in 29 cases. The major drawback of the procedure is immobilization of the patient in the hip spica for eight weeks.

  19. Subchondral insufficiency fractures of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Davies, M.; Cassar-Pullicino, V.N. [Department of Radiology, Robert Jones and Agnes Hunt Orthopaedic and District Hospital, Oswestry, SY10 7AG, Shropshire (United Kingdom); Darby, A.J. [Department of Pathology, Robert Jones and Agnes Hunt Orthopaedic and District Hospital, Oswestry, SY10 7AG, Shropshire (United Kingdom)

    2004-02-01

    The aim of this study was to increase awareness of, and to show the variable clinical and radiological features of, subchondral insufficiency fractures of the femoral head. The clinical and radiological findings in 7 patients with subchondral insufficiency fractures of the femoral head were reviewed retrospectively. The diagnosis was confirmed histologically in 4 patients. Radiographs were performed in all patients, MRI in 5 and scintigraphy in 4 patients. Radiographs showed varying degrees of femoral head collapse in 4 patients. In the remaining 3 patients radiographs showed a normal femoral head, regional osteoporosis and focal sclerosis, respectively. Magnetic resonance imaging showed a low-signal band on T1- and T2-weighted images in the subchondral bone adjacent or parallel to the articular surface associated with bone marrow oedema. Scintigraphy showed increased uptake in the femoral head. Insufficiency fractures of the femoral head are easily overlooked or confused with avascular necrosis and, when there is significant joint destruction, osteoarthritis. Unsuspected insufficiency fracture of the femoral head can lead to significant and rapid loss of bone stock in osteoporotic patients waiting for arthroplasty for osteoarthritis. Increased awareness of this condition will hopefully lead to earlier diagnosis and a successful outcome of conservative treatment. (orig.)

  20. Repeat LISS treatment for femoral shaft fractures due to hardware failure: a retrospective analysis of eleven cases.

    Science.gov (United States)

    Li, Xu; Xu, Xian; Liu, Lin; Shao, Qin; Wu, Wei

    2013-10-01

    To evaluate the effectiveness of a replating technique having a less-invasive stabilization system (LISS) for femoral shaft fractures due to LISS failure in adults. There were 11 patients with hardware failure of LISS for femoral shaft fractures, on an average of 50 days after the primary operation. The failed implants were removed, and the fractures were replated with a LISS following the rationale of biological osteosynthesis. Radiological fracture union and incidence of postoperative complications were employed to evaluate the effectiveness of this replating technique for femoral shaft fractures. Operative duration including removing failed hardware and replating fractures averaged 81.5 min, with an average blood loss of 330 ml. Patients had an average follow-up of 25.7 months. Radiological evaluation indicated that fracture union occurred in an average of 4.4 months in all patients. The length and alignment of the affected limb were satisfactory, and hardware failure did not recur. The replating technique with LISS for femoral shaft fractures due to hardware failure of LISS can obtain satisfactory results when the appropriate rationale of biological osteosynthesis and functional exercise is followed.

  1. Flexible intramedullary nailing for femoral diaphyseal fractures in children

    Directory of Open Access Journals (Sweden)

    Rojan Tamrakar

    2017-12-01

    Full Text Available Background & Objectives: Although various treatment options are available for the treatment of femoral diaphyesal fractures in children, the titanium flexible nailing has gained popularity because it is safe, easy procedure with rapid recovery and high success rate. The aim of this study was to evaluate the outcome of titanium elastic nails in treating paediatric femoral diaphyesal fractures at Patan Hospital.Materials & Methods: There were 35 cases which were all fixed with titanium flexible intramedullary nail under image intensifier at the Patan hospital from January 2013 and December 2015. Patients were evaluated in follow-ups to observe the alignment of fracture, infection, delayed union, nonunion, limb length discrepancy, implant failure, range of movement of hip and knee joints, and time to unite the fracture. The final results were evaluated using criteria of titanium elastic nail (TEN outcome score described by Flynn et al.Results: The mean age of the patients was 8.51 years. Among 35 patients (22 boys and 13 girls, there were 19 mid-shaft fractures, nine proximal third fractures and seven distal third fractures. Fracture patterns were transverse (22, oblique (10, spiral (2, and comminuted (2. The mean time for fracture union was 8.17 weeks radiologically whereas 9.83 weeks clinically. According to TEN outcome score, excellent and good results were in 28 cases (80% and seven cases (20% respectively.Conclusion: Flexible titanium nailing is a safe and satisfactory treatment for diaphyseal femoral fractures in children, because it provides rapid recovery, short rehabilitation and immobilization as well as very high union rate with few complications.

  2. Comparative characteristics of osteosynthesis techniques in patients with comminuted diaphyseal femoral fractures

    Directory of Open Access Journals (Sweden)

    A. P. Barabash

    2013-01-01

    Full Text Available The comparative analysis of the results of the surgical treatment of 130 patients with closed comminuted unilateral diaphyseal femoral fractures, including assessment of anatomic functional outcomes of treatment according to the technique of the standardized investigations in traumatology and orthopedy and determination of quality of life according to SF-36 method is carried out. Osteosynthesis with the help of external fixation devices was performed in 36 patients, intramedullary interlocking osteosynthesis - in 57 patients, compression plating - in 37 patients. Level of anatomic functional rehabilitation of the patients in the early postoperative period made up 69-79 %, 6 months later increased up to 74-92%, and after the expiration of 12 months the level of rehabilitation reached 85-99%. During the treatment quality of life concerning physical component was within the limits from 36,8 up to 55,5 %, and concerning mental component - 54,3-60,8 %. After the expiration of a year increase in the parameters of physical and mental components up to 55,7 - 59,8 % and 57,2-65,8 % is detected respectively. In the group where the transosseous osteosynthesis technique was applied we got 93,7-95 % of positive outcomes, with the average disability period of 212,3±18,1 days. In 47,2 % of cases the following complications are observed: knee contracture - 7; inflammation of the soft tissues located near the transosseous fixators - 5 (13,9%; shortening of the limb less than 5% of its length - 3; false joint formation - 1; fracture union with formation of varus deformity in the femoral bone - 1. When using intramedullary interlocking osteosynthesis we had positive results in 96,5 % of cases, with the average period of disability 176±17,8 days. In 10,5 % cases the following complications are observed: suture sinus - 1(1,75 %; femoral osteomyelitis - 1; break of the design - 1; false joint formation - 1; knee contracture - 1; shortening of the limb less than 5

  3. Dependency of Tunneling-Magnetoresistance Ratio on Nanoscale Spacer Thickness and Material for Double MgO Based Perpendicular-Magnetic-Tunneling-Junction

    Science.gov (United States)

    Lee, Du-Yeong; Hong, Song-Hwa; Lee, Seung-Eun; Park, Jea-Gun

    2016-12-01

    It was found that in double MgO based perpendicular magnetic tunneling junction spin-valves ex-situ annealed at 400 °C, the tunneling magnetoresistance ratio was extremely sensitive to the material and thickness of the nanoscale spacer: it peaked at a specific thickness (0.40~0.53 nm), and the TMR ratio for W spacers (~134%) was higher than that for Ta spacers (~98%). This dependency on the spacer material and thickness was associated with the (100) body-centered-cubic crystallinity of the MgO layers: the strain enhanced diffusion length in the MgO layers of W atoms (~1.40 nm) was much shorter than that of Ta atoms (~2.85 nm) and the shorter diffusion length led to the MgO layers having better (100) body-centered-cubic crystallinity.

  4. Case report: AVN of the femoral head five year follow-up of the combination of ipsilateral femoral neck and sub-trochanteric fracture.

    Science.gov (United States)

    Zhang, Wei; Zhu, Feng; Dong, Hanqing; Xu, Yaozeng

    2016-04-01

    To our knowledge, the type of combination of ipsilateral femoral neck and sub-trochanteric fracture is rare. And the long term follow-up is seldom been reported. A 60 year old woman suffered from a traffic accident. We gave her the intramedullary nail treatment for the combination of ipsilateral femoral neck and sub-trochanteric fracture, and the fracture indeed cured after one year and there is no clue of necrosis of the femoral head, but after 5 years, there is an evidence of necrosis of the femoral head. Combination of ipsilateral femoral neck and sub-trochanteric fracture should be kept in mind. Patients with this unusual fracture should be kept under surveillance for longer than might be thought currently to be necessary for there is a possibility of necrosis of the femoral head, even a nondisplaced femoral neck fracture.

  5. Quantum tunneling resonant electron transfer process in Lorentzian plasmas

    International Nuclear Information System (INIS)

    Hong, Woo-Pyo; Jung, Young-Dae

    2014-01-01

    The quantum tunneling resonant electron transfer process between a positive ion and a neutral atom collision is investigated in nonthermal generalized Lorentzian plasmas. The result shows that the nonthermal effect enhances the resonant electron transfer cross section in Lorentzian plasmas. It is found that the nonthermal effect on the classical resonant electron transfer cross section is more significant than that on the quantum tunneling resonant charge transfer cross section. It is shown that the nonthermal effect on the resonant electron transfer cross section decreases with an increase of the Debye length. In addition, the nonthermal effect on the quantum tunneling resonant electron transfer cross section decreases with increasing collision energy. The variation of nonthermal and plasma shielding effects on the quantum tunneling resonant electron transfer process is also discussed

  6. Fracturing of revision of a cobalt-chrome femoral head after fracturing of a ceramic femoral head, with diffuse metallosis. Case report

    Directory of Open Access Journals (Sweden)

    Pedro Miguel Dantas Costa Marques

    2013-04-01

    Full Text Available We presente a case of a fracture of a cobalt-chrome femoral head after revision of a hip total prosthesis with ceramic femoral head fracture. During surgery we found the cobalt-chrome femoral head fracture, wear of the polyethylene and massive metallosis in muscular and cartilaginous tissue. Both femoral stem and acetabular cup were stable and without apparent wearing. After surgical debridement, we promoted the substitution of the femoral head and the acetabular polyethylene by similar ones. After 12 months of follow-up, the patient has no pain complaints, function limit or systemic signs associated with malign metallosis

  7. The Beginner's Guide to Wind Tunnels with TunnelSim and TunnelSys

    Science.gov (United States)

    Benson, Thomas J.; Galica, Carol A.; Vila, Anthony J.

    2010-01-01

    The Beginner's Guide to Wind Tunnels is a Web-based, on-line textbook that explains and demonstrates the history, physics, and mathematics involved with wind tunnels and wind tunnel testing. The Web site contains several interactive computer programs to demonstrate scientific principles. TunnelSim is an interactive, educational computer program that demonstrates basic wind tunnel design and operation. TunnelSim is a Java (Sun Microsystems Inc.) applet that solves the continuity and Bernoulli equations to determine the velocity and pressure throughout a tunnel design. TunnelSys is a group of Java applications that mimic wind tunnel testing techniques. Using TunnelSys, a team of students designs, tests, and post-processes the data for a virtual, low speed, and aircraft wing.

  8. Large Magnetoresistance at Room Temperature in Organic Molecular Tunnel Junctions with Nonmagnetic Electrodes.

    Science.gov (United States)

    Xie, Zuoti; Shi, Sha; Liu, Feilong; Smith, Darryl L; Ruden, P Paul; Frisbie, C Daniel

    2016-09-27

    We report room-temperature resistance changes of up to 30% under weak magnetic fields (0.1 T) for molecular tunnel junctions composed of oligophenylene thiol molecules, 1-2 nm in length, sandwiched between gold contacts. The magnetoresistance (MR) is independent of field orientation and the length of the molecule; it appears to be an interface effect. Theoretical analysis suggests that the source of the MR is a two-carrier (two-hole) interaction at the interface, resulting in spin coupling between the tunneling hole and a localized hole at the Au/molecule contact. Such coupling leads to significantly different singlet and triplet transmission barriers at the interface. Even weak magnetic fields impede spin relaxation processes and thus modify the ratio of holes tunneling via the singlet state versus the triplet state, which leads to the large MR. Overall, the experiments and analysis suggest significant opportunities to explore large MR effects in molecular tunnel junctions based on widely available molecules.

  9. Femoral shaft bowing in the coronal plane has more significant effect on the coronal alignment of TKA than proximal or distal variations of femoral shape.

    Science.gov (United States)

    Kim, Jong-Min; Hong, Soo-Heon; Kim, Jong-Min; Lee, Bum-Sik; Kim, Dong-Eun; Kim, Kyung-Ah; Bin, Seong-Il

    2015-07-01

    The aim of this study was to determine (1) variations in the shape of the proximal, middle, and distal femur in a series of Korean patients who had undergone total knee arthroplasty (TKA), (2) the preoperative relationship between these three parameters and the distal valgus cutting angle referenced off the femoral intramedullary guide, and (3) whether there was any relationship between femoral bowing and variations in the shape of the proximal or distal femur in the coronal plane. The preoperative long-standing anteroposterior radiographs of 316 consecutive osteoarthritis patients who underwent primary TKA from 2009 to 2011 were examined. The femoral neck shaft angle, the femoral shaft bowing angle, and the mechanical lateral distal femoral angle were measured to assess the shape of the proximal, middle, and distal femur, respectively. The valgus cutting angle of the femur was defined as the angle between the distal anatomical and mechanical axes of the femur. The study population showed large variations in femoral shape. The mean femoral intramedullary guide angle was 6.5° ± 1.3° (range: 4°-13°). The femoral shaft bowing angle was the factor that showed the strongest correlation with this angle (P shaft angle showed no correlation (n.s.). The femoral shaft bowing angle showed a weak correlation with the mechanical lateral distal femoral angle (P = 0.001), but was not significantly correlated with the femoral neck shaft angle (n.s.). Apparent femoral bowing (>3° of lateral or medial bowing) was found in 42 (13.3 %) of cases (37 cases of lateral bowing and five of medial bowing). Cases with lateral apparent femoral bowing >3° had a distal cutting angle of 8.6° ± 2.2° relative to the femoral intramedullary guide. The femoral intramedullary guide angle was mainly influenced by femoral shaft bowing among femoral deformities in the coronal plane. Therefore, to increase the accuracy of distal femoral cut during TKA, it is necessary to confirm femoral

  10. Production of oscillatory flow in wind tunnels

    Science.gov (United States)

    Al-Asmi, K.; Castro, I. P.

    1993-06-01

    A method for producing oscillatory flow in open-circuit wind tunnels driven by centrifugal fans is described. Performance characteristics of a new device installed on two such tunnels of greatly differing size are presented. It is shown that sinusoidal variations of the working section flow, having peak-to-peak amplitudes up to at least 30 percent of the mean flow speed and frequencies up to, typically, that corresponding to the acoustic quarter-wave-length frequency determined by the tunnel size, can be obtained with negligible harmonic distortion or acoustic noise difficulties. A brief review of the various methods that have been used previously is included, and the advantages and disadvantages of these different techniques are highlighted. The present technique seems to represent a significant improvement over many of them.

  11. Fire safety case study of a railway tunnel: Smoke evacuation

    Directory of Open Access Journals (Sweden)

    van Maele Karim

    2007-01-01

    Full Text Available When a fire occurs in a tunnel, it is of great importance to assure the safety of the occupants of the tunnel. This is achieved by creating smoke-free spaces in the tunnel through control of the smoke gases. In this paper, results are presented of a study concerning the fire safety in a real scale railway tunnel test case. Numerical simulations are performed in order to examine the possibility of natural ventilation of smoke in inclined tunnels. Several aspects are taken into account: the length of the simulated tunnel section, the slope of the tunnel and the possible effects of external wind at one portal of the tunnel. The Fire Dynamics Simulator of the National Institute of Standards and Technology, USA, is applied to perform the simulations. The simulations show that for the local behavior of the smoke during the early stages of the fire, the slope of the tunnel is of little importance. Secondly, the results show that external wind and/or pressure conditions have a large effect on the smoke gases inside the tunnel. Finally, some idea for the value of the critical ventilation velocity is given. The study also shows that computational fluid dynamics calculations are a valuable tool for large scale, real life complex fire cases. .

  12. Slipped capital femoral epiphysis: A modern treatment protocol

    Directory of Open Access Journals (Sweden)

    Slavković Nemanja

    2009-01-01

    Full Text Available The treatment of a patient with slipped capital femoral epiphysis begins with an early diagnosis and accurate classification. On the basis of symptom duration, clinical findings and radiographs, slipped capital femoral epiphysis is classified as pre-slip, acute, acute-on-chronic and chronic. The long-term outcome of slipped capital femoral epiphysis is directly related to severity and the presence or absence of avascular necrosis and/or chondrolysis. Therefore, the first priority in the treatment of slipped capital femoral epiphysis is to avoid complications while securing the epiphysis from further slippage. Medical treatment of patients with acute and acute-on-chronic slipped capital femoral epiphysis, as well as those presented in pre-slip stage, is the safest, although time-consuming. Manipulations, especially forced and repeated, are not recommended due to higher avascular necrosis risk. The use of intraoperative fluoroscopy to assist in the placement of internal fixation devices has markedly increased the success of surgical treatment. Controversy remains as to whether the proximal femoral epiphysis in severe, chronic slipped capital femoral epiphysis should be realigned by extracapsular osteotomies or just fixed in situ. The management protocol for slipped capital femoral epiphysis depends on the experience of the surgeon, motivation of the patient and technical facilities.

  13. New Knowledge of tunneling from photonic experiments

    International Nuclear Information System (INIS)

    Nimtz, G.

    1997-01-01

    Photonic experiments have shown, that the propagation of evanescent (tunneling) modes can proceed at speeds faster than the velocity of light in vacuum (superluminal). The superluminal velocities include signal and energy propagation. The analogy between the classical Helmholtz equation and the quantum mechanical Schroedinger equation was quantitatively proved in classical photonic experiments. The Hartman effect, i.e. the prediction that the tunneling time is independent of the barrier length was for the first time evidenced in a photonic analogous tunneling experiment by Enders and Nimtz. It is also shown, that the resonant state life time is not determined by the barrier traversal time. For electronic tunneling devices it follows, that the quantum mechanical phase time calculations indeed deliver the relevant intrinsic tunneling time and consequently allow to predict the dynamical specification of a device. The present theoretical descriptions of the propagation of evanescent modes is not fully compatible with the experimental situation. Superluminal signal and energy transport has been measured, and this has to be properly analyzed. May the advanced field solutions help to obtain a satisfactory theoretical description of the recent experimental results of the propagation of evanescent modes? (author)

  14. Frequency of ipsilateral femoral neck fractures in patients with ...

    African Journals Online (AJOL)

    Background: Ipsilateral associated femoral neck and shaft fractures are reported to occur in 2.5-6% of all femoral shaft fractures. Objective: To establish the frequency of ipsilateral femoral neck fractures amongst all patients presenting with femoral shaft fractures in Mulago Hospital. Methodology: This was a descriptive ...

  15. Femoral neck-shaft angle in extra-capsular proximal femoral fracture fixation; does it make a TAD of difference?

    Science.gov (United States)

    Walton, N P; Wynn-Jones, H; Ward, M S; Wimhurst, J A

    2005-11-01

    The effect of femoral neck-shaft angle and implant type on the accuracy of lag screw placement in extra-capsular proximal femoral fracture fixation was investigated. Radiographs of all extra-capsular proximal femoral fractures seen in one unit over 18 months were reviewed. Of 399 cases, 307 (237 female, 70 male) were included in the study as they had no contra-lateral proximal femoral metal work. Femoral neck-shaft angle (NSA) of the uninjured hip and magnification adjusted tip-apex distance (TAD) of femoral head lag screw were measured. Type of fixation implant was 135 degrees classic hip screw (CHS) (n=144) or 130 degrees intra-medullary hip screw (IMHS) (n=163). Mean contra-lateral NSA was 130.2 degrees (112.9--148 degrees ) and 64 patients (58 female, 6 male) had a NSA TAD was 18.7 mm (5.8--43.8mm) and 88.9% of cases had a TAD of less than 25 mm. TAD values were significantly greater using an IMHS if NSA was 125 degrees (p=0.028). This was not the case with the CHS. The use of the 130 degrees -IMHS in patients with a NSA 125 degrees and caution is advocated when using this device in such cases.

  16. Incidence of Avascular Necrosis of the Femoral Head After Intramedullary Nailing of Femoral Shaft Fractures

    Science.gov (United States)

    Kim, Ji Wan; Oh, Jong-Keon; Byun, Young-Soo; Shon, Oog-Jin; Park, Jai Hyung; Oh, Hyoung Keun; Shon, Hyun Chul; Park, Ki Chul; Kim, Jung Jae; Lim, Seung-Jae

    2016-01-01

    Abstract The goal of this study was to determine the incidence of avascular necrosis of the femoral head (AVNFH) after intramedullary nailing of femoral shaft fractures and to identify risk factors for developing AVNFH. We retrospectively reviewed all patients with femoral shaft fractures treated with antegrade intramedullary nailing at 10 institutions. Among the 703 patients enrolled, 161 patients were excluded leaving 542 patients in the study. Average age was 42.1 years with average follow-up of 26.3 months. Patient characteristics and fracture patterns as well as entry point of femoral nails were identified and the incidence of AVNFH was investigated. Patients were divided into 2 groups according to open versus closed physis, open versus closed fractures, and age (<20 versus ≥20 years). Overall incidence of AVNFH was 0.2% (1 of 542): the patient was 15-year-old boy. Of 25 patients with open physis, the incidence of AVNFH was 4%, whereas none of 517 patients with closed physis developed AVNFH (P < 0.001). The incidence of AVNFH in patients aged < 20 versus ≥20 years was 1.1% (1 of 93) and 0.0% (0 of 449), respectively (P = 0.172), which meant that the incidence of AVNFH was 0% in adult with femur shaft fracture. Of 61 patients with open fractures, the incidence of AVNFH was 0%. The number of cases with entry point at the trochanteric fossa or tip of the greater trochanter (GT) was 324 and 218, respectively, and the incidence of AVNFH was 0.3% and 0.0%, respectively (P = 0.412). In patients aged ≥20 years with isolated femoral shaft fracture, there was no case of AVNFH following antegrade intramedullary nailing regardless of the entry point. Therefore, our findings suggest that the risk of AVNFH following antegrade femoral nailing is extremely low in adult patients. PMID:26844518

  17. Design Optimization of Liquid Nitrogen Based IQF Tunnel

    Science.gov (United States)

    Datye, A. B.; Narayankhedkar, K. G.; Sharma, G. K.

    2006-04-01

    A design methodology for an Individual Quick Freezing (IQF) tunnel using liquid nitrogen is developed and the design based on this methodology is validated using the data of commercial tunnels. The design takes care of heat gains due to the conveyor belt which is exposed to atmosphere at the infeed and outfeed ends. The design also considers the heat gains through the insulation as well as due to circulating fans located within the tunnel. For minimum liquid nitrogen consumption, the ratio of the length of the belt, L (from infeed to out feed) to the width of the belt, W can be considered as a parameter. The comparison of predicted and reported liquid nitrogen (experimental data) consumption shows good agreement and is within 10 %.

  18. Avascular necrosis of the femoral head after osteosynthesis of femoral neck fracture.

    Science.gov (United States)

    Min, Byung-Woo; Kim, Sung-Jin

    2011-05-18

    The reported incidence of avascular necrosis after femoral neck fracture fixation varies widely, and there is no consensus regarding its risk factors. We evaluated the incidence of avascular necrosis of the femoral head with the use of contemporary techniques for femoral neck fracture fixation. We then sought to determine what potential risk factors influenced the development of avascular necrosis.Between 1990 and 2005, one hundred sixty-three intracapsular femoral neck fractures in 163 patients were treated with internal fixation at our level-I trauma center. All patients were monitored until conversion to total hip arthroplasty or for a minimum of 2 years postoperatively. Ten patients (10 hips) died and 7 patients (7 hips) were lost to follow-up. The remaining 146 patients (146 hips) had a mean 5.2 years of follow-up (range, 3 months to 17 years). The incidence of avascular necrosis was 25.3% (37 hips). The average time to diagnosis of avascular necrosis was 18.8 months (range, 3-47 months). Patient sex, age, interval from injury to surgery, and mechanism of injury were statistically not associated with the development of avascular necrosis. The quality of fracture reduction, adequacy of fixation, degree of displacement, and comminution of the posterior cortex were significantly associated. After we controlled for patient and radiographic characteristics, multivariate analyses indicated that the important predictors for avascular necrosis are poor reduction (odds ratio=13.889) and initial displacement of the fracture (odds ratio=4.693). Copyright 2011, SLACK Incorporated.

  19. Tunneling magnetoresistance in Si nanowires

    KAUST Repository

    Montes Muñoz, Enrique

    2016-11-09

    We investigate the tunneling magnetoresistance of small diameter semiconducting Si nanowires attached to ferromagnetic Fe electrodes, using first principles density functional theory combined with the non-equilibrium Green\\'s functions method for quantum transport. Silicon nanowires represent an interesting platform for spin devices. They are compatible with mature silicon technology and their intrinsic electronic properties can be controlled by modifying the diameter and length. Here we systematically study the spin transport properties for neutral nanowires and both n and p doping conditions. We find a substantial low bias magnetoresistance for the neutral case, which halves for an applied voltage of about 0.35 V and persists up to 1 V. Doping in general decreases the magnetoresistance, as soon as the conductance is no longer dominated by tunneling.

  20. Femoral neck buttressing: a radiographic and histologic analysis

    International Nuclear Information System (INIS)

    Dixon, T.; Benjamin, J.; Lund, P.; Graham, A.; Krupinski, E.

    2000-01-01

    Objective. To examine the incidence, radiographic and histologic findings of medial femoral neck buttressing in a consecutive group of patients undergoing total hip arthroplasty.Design. Biomechanical parameters were evaluated on standard anteroposterior pelvic radiographs of 113 patients prior to hip replacement surgery. Demographic information on all patients was reviewed and histologic evaluation was performed on specimens obtained at the time of surgery.Results. The incidence of medial femoral neck buttressing was found to be 50% in a consecutive series of patients undergoing total hip arthroplasty. The incidence was slightly higher in women (56% vs 41%). Patients with buttressing had increased neck-shaft angles and smaller femoral neck diameters than were seen in patients without buttressing. Histologic evaluation demonstrated that the buttress resulted from deposition bone by the periosteum on the femoral neck in the absence of any evidence of femoral neck fracture.Conclusion. It would appear that femoral neck buttressing occurs in response to increased joint reactive forces seen at the hip being transmitted through the femoral neck. The increased joint reactive force can be related to the increased neck shaft angle seen in patients with buttressing. (orig.)

  1. Challenges and Thoughts on Risk Management and Control for the Group Construction of a Super-Long Tunnel by TBM

    Directory of Open Access Journals (Sweden)

    Mingjiang Deng

    2018-02-01

    Full Text Available The total length of the second stage of the water supply project in the northern areas of the Xinjiang Uygur Autonomous Region is 540 km, of which the total length of the tunnels is 516 km. The total tunneling mileage is 569 km, which includes 49 slow-inclined shafts and vertical shafts. Among the tunnels constructed in the project, the Ka–Shuang tunnel, which is a single tunnel with a length of 283 km, is currently the longest water-conveyance tunnel in the world. The main tunnel of the Ka–Shuang tunnel is divided into 18 tunnel-boring machine (TBM sections, and 34 drilling-and-blasting sections, with 91 tunnel faces. The construction of the Ka–Shuang tunnel has been regarded as an unprecedented challenge for project construction management, risk control, and safe and efficient construction; it has also presented higher requirements for the design, manufacture, operation, and maintenance of the TBMs and their supporting equipment. Based on the engineering characteristics and adverse geological conditions, it is necessary to analyze the major problems confronted by the construction and systematically locate disaster sources. In addition, the risk level should be reasonably ranked, responsibility should be clearly identified, and a hierarchical-control mechanism should be established. Several techniques are put forward in this paper to achieve the objectives mentioned above; these include advanced geological prospecting techniques, intelligent tunneling techniques combined with the sensing and fusion of information about rock parameters and mechanical parameters, monitoring and early-warning techniques, and modern information technologies. The application of these techniques offers scientific guidance for risk control and puts forward technical ideas about improving the efficiency of safe tunneling. These techniques and ideas have great significance for the development of modern tunneling technologies and research into major

  2. Angiographic analysis of avascular necrosis of a femoral head -selective angiography of medial femoral circumflex artery-

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Kyung Nam; Yoon, Yup; Lee, Sun Wha; Lim, Jae Hoon [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1991-07-15

    The degree of anatomical revascularization of a necrotic femoral head and traumatic hip would provide information about treatment and prognosis. The authors analyzed the vascular changes of femoral head among unilateral avascular necrosis, bilateral avascular necrosis, and traumatic hips. Forty - four patients with avascular necrosis and 19 patients with traumatic hips were examined by selective angiography of the medial femoral circumflex artery. In the traumatic hip cases, 12 (63%) showed occlusion, 2 (11%) hypertrophy of the capsular branches, and 5 ( 26 % ) were normal . In the avascular necrosis cases, 15 (25%) showed occlusion, 39 (67%) had hypertrophy of the capsular branches, and 4 (7%) had normal findings. Hypertrophy of the superior capsular branch of the medial femoral circumflex artery is more frequently observed in avascular necrosis than in traumatic hip. Bilateral avascular necrosis reveals more frequent incidences than unilateral cases. Selective angiography could help in the therapy plan and also provide information about the contralateral side.

  3. Angiographic analysis of avascular necrosis of a femoral head -selective angiography of medial femoral circumflex artery-

    International Nuclear Information System (INIS)

    Ryu, Kyung Nam; Yoon, Yup; Lee, Sun Wha; Lim, Jae Hoon

    1991-01-01

    The degree of anatomical revascularization of a necrotic femoral head and traumatic hip would provide information about treatment and prognosis. The authors analyzed the vascular changes of femoral head among unilateral avascular necrosis, bilateral avascular necrosis, and traumatic hips. Forty - four patients with avascular necrosis and 19 patients with traumatic hips were examined by selective angiography of the medial femoral circumflex artery. In the traumatic hip cases, 12 (63%) showed occlusion, 2 (11%) hypertrophy of the capsular branches, and 5 ( 26 % ) were normal . In the avascular necrosis cases, 15 (25%) showed occlusion, 39 (67%) had hypertrophy of the capsular branches, and 4 (7%) had normal findings. Hypertrophy of the superior capsular branch of the medial femoral circumflex artery is more frequently observed in avascular necrosis than in traumatic hip. Bilateral avascular necrosis reveals more frequent incidences than unilateral cases. Selective angiography could help in the therapy plan and also provide information about the contralateral side

  4. Risk stratification for avascular necrosis of the femoral head after internal fixation of femoral neck fractures by post-operative SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sang Won; Oh, Min Young; Yoon, Seok Ho; Kim, Jin Soo; Chang, Jae Suk; Ryu, Jin Sook [Asan Medical CenterUniversity of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, Ji Wan [Dept. of Orthopedic Surgery, Haeundae Paik Hospital, Inje University, Busan (Korea, Republic of)

    2017-03-15

    Avascular necrosis (AVN) of the femoral head is a major complication after internal fixation of a femoral neck fracture and determines the functional prognosis. We investigated postoperative bone single-photon emission computed tomography/computed tomography (SPECT/CT) for assessing the risk of femoral head AVN. We retrospectively reviewed 53 consecutive patients who underwent bone SPECT/CT within 2 weeks of internal fixation of a femoral neck fracture and follow-up serial hip radiographs over at least 12 months. Nine patients developed femoral head AVN. In 15 patients who showed normal uptake on immediate postoperative SPECT/CT, no AVN occurred, whereas 9 of 38 patients who showed cold defects of the femoral head later developed AVN. The negative predictive value of immediate postoperative SPECT/CT for AVN was 100 %, whereas the positive predictive value was 24 %. Among 38 patients with cold defects, 1 developed AVN 3 months postoperatively. A follow-up bone SPECT/CT was performed in the other 37 patients at 2–10 months postoperatively. The follow-up bone SPECT/CT revealed completely normalized femoral head uptake in 27, partially normalized uptake in 8, and persistent cold defects in 2 patients. AVN developed in 3.7 % (1/27), 62.5 % (5/8), and 100 % (2/2) of each group, respectively. According to the time point of imaging, radiotracer uptake patterns of the femoral head on postoperative bone SPECT/CT indicate the risk of AVN after internal fixation of femoral neck fractures differently. Postoperative bone SPECT/CT may help orthopedic surgeons determine the appropriate follow-up of these patients.

  5. Risk stratification for avascular necrosis of the femoral head after internal fixation of femoral neck fractures by post-operative SPECT/CT

    International Nuclear Information System (INIS)

    Han, Sang Won; Oh, Min Young; Yoon, Seok Ho; Kim, Jin Soo; Chang, Jae Suk; Ryu, Jin Sook; Kim, Ji Wan

    2017-01-01

    Avascular necrosis (AVN) of the femoral head is a major complication after internal fixation of a femoral neck fracture and determines the functional prognosis. We investigated postoperative bone single-photon emission computed tomography/computed tomography (SPECT/CT) for assessing the risk of femoral head AVN. We retrospectively reviewed 53 consecutive patients who underwent bone SPECT/CT within 2 weeks of internal fixation of a femoral neck fracture and follow-up serial hip radiographs over at least 12 months. Nine patients developed femoral head AVN. In 15 patients who showed normal uptake on immediate postoperative SPECT/CT, no AVN occurred, whereas 9 of 38 patients who showed cold defects of the femoral head later developed AVN. The negative predictive value of immediate postoperative SPECT/CT for AVN was 100 %, whereas the positive predictive value was 24 %. Among 38 patients with cold defects, 1 developed AVN 3 months postoperatively. A follow-up bone SPECT/CT was performed in the other 37 patients at 2–10 months postoperatively. The follow-up bone SPECT/CT revealed completely normalized femoral head uptake in 27, partially normalized uptake in 8, and persistent cold defects in 2 patients. AVN developed in 3.7 % (1/27), 62.5 % (5/8), and 100 % (2/2) of each group, respectively. According to the time point of imaging, radiotracer uptake patterns of the femoral head on postoperative bone SPECT/CT indicate the risk of AVN after internal fixation of femoral neck fractures differently. Postoperative bone SPECT/CT may help orthopedic surgeons determine the appropriate follow-up of these patients

  6. Analysis of Co-Tunneling Current in Fullerene Single-Electron Transistor

    Science.gov (United States)

    KhademHosseini, Vahideh; Dideban, Daryoosh; Ahmadi, MohammadTaghi; Ismail, Razali

    2018-05-01

    Single-electron transistors (SETs) are nano devices which can be used in low-power electronic systems. They operate based on coulomb blockade effect. This phenomenon controls single-electron tunneling and it switches the current in SET. On the other hand, co-tunneling process increases leakage current, so it reduces main current and reliability of SET. Due to co-tunneling phenomenon, main characteristics of fullerene SET with multiple islands are modelled in this research. Its performance is compared with silicon SET and consequently, research result reports that fullerene SET has lower leakage current and higher reliability than silicon counterpart. Based on the presented model, lower co-tunneling current is achieved by selection of fullerene as SET island material which leads to smaller value of the leakage current. Moreover, island length and the number of islands can affect on co-tunneling and then they tune the current flow in SET.

  7. Comparative study on anterior cruciate ligament reconstruction: determination of isometric points with and without navigation

    Directory of Open Access Journals (Sweden)

    Fabio J. Angelini

    2010-01-01

    Full Text Available OBJECTIVES: To compare the accuracy of tunnel placement and graft isometry for anterior cruciate ligament reconstruction performed using a computer-assisted navigation system (Orthopilot and using traditional instruments. METHODS: The anterior cruciate ligament was removed intact from 36 pairs of human cadaver knees. From each pair, one knee was randomized to Group 1 (conventional and the other to Group 2 (Orthopilot. An inelastic suture was then passed through the central points of the tibial and femoral tunnels. Neither of the tunnels was drilled. All knees were then dissected, and six parameters were obtained: distances from the tibial tunnel center to the 1 posterior cruciate ligament, 2 anterior horn of the lateral meniscus and 3 medial tibial spine; 4 distance from the femoral tunnel center to the posterior femoral cortex; 5 femoral tunnel coronal angle; and 6 variation of the distance from the femoral to the tibial tunnel with the knee extended and at 90 degrees of flexion. RESULTS: The variation of the distance from the femoral to the tibial tunnel during flexion and extension was smaller in the Orthopilot group (better isometry compared to the conventional group. There were no statistical differences in any other parameters between the groups, and all tunnels were considered to be in satisfactory positions. DISCUSSION: The results obtained for anterior cruciate ligament reconstruction depend on precise isometric point positioning, and a navigation system is a precision tool that can assist surgeons in tunnel positioning. CONCLUSION: No differences in tunnel position were observed between the groups. Nonetheless, better isometry was achieved in the Orthopilot group than with conventional instruments.

  8. Ipsilateral femoral neck and shaft fractures: An overlooked association

    International Nuclear Information System (INIS)

    Daffner, R.H.; Riemer, B.L.; Butterfield, S.L.

    1991-01-01

    A total of 304 patients with injuries to the femoral shaft and ipsilateral hip presented between 1984 and 1990. Some 253 of them suffered fractures of the femoral shaft and dislocated hips or fractures of the acetabulum, and 51 of these sustained fractures of the femoral shaft and neck or trochanteric region. All of the trochanteric injuries were demonstrated on the initial radiographs. However, in 11 of the patients with combined femoral shaft and neck fractures, the diagnosis was delayed by as much as 4 weeks. This delay related to the fact that these fractures tended not to separate in the initial evaluation period and that there was external rotation of the proximal femoral fragment due to the femoral shaft fracture. (orig./GDG)

  9. Ipsilateral femoral neck and shaft fractures: An overlooked association

    Energy Technology Data Exchange (ETDEWEB)

    Daffner, R.H. (Dept. of Diagnostic Radiology, Allegheny General Hospital, Pittsburgh, PA (USA) Medical Coll. of Pennsylvania, Pittsburgh, PA (USA)); Riemer, B.L.; Butterfield, S.L. (Dept. of Orthopedic Surgery, Allegheny General Hospital, Pittsburgh, PA (USA) Medical Coll. of Pennsylvania, Pittsburgh, PA (USA))

    1991-05-01

    A total of 304 patients with injuries to the femoral shaft and ipsilateral hip presented between 1984 and 1990. Some 253 of them suffered fractures of the femoral shaft and dislocated hips or fractures of the acetabulum, and 51 of these sustained fractures of the femoral shaft and neck or trochanteric region. All of the trochanteric injuries were demonstrated on the initial radiographs. However, in 11 of the patients with combined femoral shaft and neck fractures, the diagnosis was delayed by as much as 4 weeks. This delay related to the fact that these fractures tended not to separate in the initial evaluation period and that there was external rotation of the proximal femoral fragment due to the femoral shaft fracture. (orig./GDG).

  10. Efficacy Evaluation for the Treatment of Subcapital Femoral Neck Fracture in Young Adults by Capsulotomy Reduction and Closed Reduction

    Directory of Open Access Journals (Sweden)

    Cong Liu

    2015-01-01

    Full Text Available Background: Subcapital femoral neck fracture in young adults has many complications, and the incidence is increasing year-by-year. The selection of the proper operation method to avoid them is an ambiguous matter. This study aimed to evaluate the treatment effect of subcapital femoral neck fracture by the capsulotomy and internal fixation with iliac bone grafting or closed reduction and internal fixation in young adults. Methods: From March 2003 to February 2010, 65 young patients with subcapital femoral neck fractures were treated, including 39 males and 26 females with average age of 34.5 years (range, 19-50 years; 29 cases of the left side and 36 cases of the right side. They were randomly divided into Group A with 34 cases treated by closed reduction and internal fixation and Group B with 31 cases treated by the capsulotomy and internal fixation with iliac bone grafting. The two groups had no significant differences in sex, age, body mass index and preoperative Harris Hip Score. The observation criteria involved the length of the incision, blood loss, operation time, nonunion rate, avascular necrosis of the femoral head (ANFH rate and Harris Hip Score. Results: Four of 65 patients were lost follow-up, and the follow-up rate was 93.8%, the average follow-up time was 38.7 months (range, 33-47 months. In Group A, the incision length was 5.1 ± 2.2 cm, blood loss was 84.0 ± 13.2 ml, and operation time was 52.9 ± 10.2 min. In Group B, the incision length was 15.4 ± 4.6 cm, blood loss was 396.0 ± 21.3 ml, and operation time was 116.5 ± 15.3 min. Nonunion occurred in 8 patients (25.2% in Group A and 1 patient (3.3% in Group B. ANFH occurred in 9 patients (29.1% in Group A and 2 patients (6.7% in Group B. Postoperative Harris Hip Score was 89.0 ± 5.6 in Group A and 95.0 ± 4.5 in Group B. The above index of two groups was considered statistically significant (P < 0.05. Conclusions: Capsulotomy and internal fixation with iliac bone grafting can

  11. Knee stabiligy after ACL reconstruction through graft fixation in femoral tunnel: transfemoral pinning versus endobutton techniques

    Directory of Open Access Journals (Sweden)

    Tahmasebi MN

    2011-05-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 st1":*{behavior:url(#ieooui } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: One of the most common orthopedic complaints is direct or indirect trauma to the knee with torn anterior cruciate ligament (ACL. Reconstruction of the torn ACL is emphatically offered in active individuals as by this operation, we prevent osteoarthritis, knee instability and injury to the meniscus. There are numerous methods for graft fixation in the femoral tunnel in ACL reconstruction. If the graft proves to be stable after the operation, patients would not complain of giving way knee joints. In this clinical trial, we compared transfemoral pinning with endobutton fixation of hamstring graft in arthroscopic ACL reconstruction by examining knee stability and use of other relevant functional tests. "n"nMethods : Fourteen Patients who had undergone arthroscopic ACL reconstruction in Shariati Hospital during the years 2008-2009 and were being followed up were evaluated at least 15 months post-operatively by physical examination and the use of an arthrometer made by the Faculty of Mechanics of Sharif Technical University."n"nResults : The results showed that two out of seven patients in which their ACL had been reconstructed by hamstring graft fixation by endobutton technique, and

  12. Satisfactory Results of the Exeter Revision Femoral Stem Used for Primary Total Hip Arthroplasty.

    Science.gov (United States)

    Desy, Nicholas M; Johnson, Joshua D; Sierra, Rafael J

    2017-02-01

    The Exeter cemented femoral stem has demonstrated excellent clinical and radiographic outcomes as well as long-term survivorship free from aseptic loosening. A shorter revision stem (125 mm) with a 44 offset became available for the purpose of cement-in-cement revision situations. In certain cases, this shorter revision stem may be used for various primary total hip arthroplasties (THAs) where the standard length stem would require distally reaming the femoral canal. We sought to report on the early to midterm results of this specific stem when used for primary THA regarding (1) clinical and radiographic outcomes, (2) complications, and (3) survivorship. Twenty-nine patients (33 hips) underwent a hybrid THA using the smaller revision Exeter cemented femoral stem. Twenty-five patients (28 hips) had at least 2 years of follow-up and were assessed for clinical and radiographic outcomes. All 33 hips were included in the analysis of complications and survivorship. The Kaplan-Meier survivorship was performed using revision for all causes and for aseptic loosening as the end points. The average clinical follow-up was 4 years (range, 2-7). Harris Hip Scores improved from a mean preoperative value of 56 (range, 23-96) to 90 (range, 51-100) at the latest follow-up. All patients demonstrated superior cement mantles with no signs of loosening. One patient suffered a B2 periprosthetic fracture and 1 patient experienced 2 episodes of instability. The 5-year Kaplan-Meier survivorship was 96.7% for all causes of revision and was 100% using aseptic loosening as the end point. The shorter Exeter revision cemented femoral stem has favorable early to midterm clinical and radiographic outcomes when used for primary THA with a low complication rate and is a viable option in patients with narrow femoral canals where uncemented stem fixation is not desired. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. [Postoperative analgesia in knee arthroplasty using an anterior sciatic nerve block and a femoral nerve block].

    Science.gov (United States)

    del Fresno Cañiaveras, J; Campos, A; Galiana, M; Navarro-Martínez, J A; Company, R

    2008-11-01

    To evaluate the efficacy of a nerve block as an alternative technique for analgesia after knee arthroplasty and to indicate the usefulness and advantages of the anterior approach to the sciatic nerve block. Between April 2004 and March 2006, we studied a series of consecutive patients undergoing knee arthroplasty in which a subarachnoid block was used as the anesthetic technique and postoperative analgesia was provided by means of a combined peripheral femoral nerve block and an anterior sciatic nerve block. We evaluated the mean length of time free from pain, quality of analgesia, and length of stay in hospital. Seventy-eight patients were included in the study. The mean (SD) length of time free from pain for the group was 42.1 (3.9) hours. Patients reported mild pain after 34.8 (4.1) hours and moderate to severe pain after 42.4 (3.5) hours. By the third day, 62.8% of patients were able to bend the knee to 90 degrees. There were no complications resulting from the technique and the level of patient satisfaction was high. A combined femoral-sciatic nerve block is effective in knee arthroplasty. It controls postoperative pain and allows for early rehabilitation. The anterior approach to the sciatic nerve is relatively simple to perform without removing the pressure bandaging from the thigh after surgery. This approach also makes it unnecessary to move the patient.

  14. Femoral component rotation in patellofemoral joint replacement.

    Science.gov (United States)

    van Jonbergen, Hans-Peter W; Westerbeek, Robin E

    2018-06-01

    Clinical outcomes in patellofemoral joint replacement may be related to femoral component rotation. Assessment of rotational alignment is however difficult as patients with isolated patellofemoral osteoarthritis often have trochlear dysplasia. The use of the medial malleolus as a landmark to guide rotation has been suggested. The purpose of our study was to evaluate this technique with regard to femoral component rotation, and to correlate rotation with clinical outcomes at one-year follow-up. Forty-one knees in 39 patients had patellofemoral joint replacement using the Zimmer Gender-Solutions patellofemoral prosthesis. Intraoperatively, we determined femoral component rotational alignment using an extramedullary rod aimed at the inferior tip of the medial malleolus. Postoperatively, we measured the angle between the femoral component and the anatomical transepicondylar axis using CT. The amount of rotation was correlated with clinical outcomes at one-year follow-up. Forty knees in 38 patients were available for one-year follow-up. Mean femoral component rotation relative to the anatomical transepicondylar axis was 1.4° external rotation (range, -3.8 to 5.7°). We found no statistically significant correlation between femoral component rotation and change from baseline KOOS subscales at one-year follow-up. Our findings show that when using the medial malleolus as a landmark to guide rotation, the femoral component of the patellofemoral prosthesis was oriented in external rotation relative to the anatomical transepicondylar axis in 80% of knees. Our study did not show a relation between the amount of external rotation and clinical outcomes. Level III. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Press-fit Femoral Fixation in ACL Reconstruction using Bone-Patellar Tendon-Bone Graft

    Directory of Open Access Journals (Sweden)

    Kaseb Mohammad Hasan

    2009-05-01

    Full Text Available Bone-patellar tendon auto graft is probably the most widely used graft for ACL reconstruction. Several methods for graft fixation have been described. To avoid intra-articular hardware we adopt biological fixation with a femoral trapezoidal press-fit fixation. A prospective study was performed on 30 consecutive active people who underwent ACL reconstruction with this technique by two surgeons between september2004 and march2007 (mean follow-up 15.2 months. Results were evaluated by an independent examiner using radiography, subjective and objective evaluation. Assessment using the IKDC knee scoring revealed 92% of the patients with a normal or nearly normal knee joint. Lysholm's score was 63.6(40- 86 preoperatively and 91.88(73-100 at the latest follow up (P < 0.005. No patient complained of instability at latest follow up. The quadriceps muscle showed mild atrophy at 3 and 6 months and at final follow-up. Five Patients complained of anterior knee pain and had a positive kneeling test. We found no graft displacement on follow up radiographs. All cases showed radiological evidence of graft osteointegration at last follow up. Our results show that press-fit fixation of trapezoidal bone graft in femoral tunnel is a simple, reliable, and cost-effective alternative for ACL recon-struction using bone-patellar tendon-bone graft.

  16. Clinical study on 44 cases of femoral hernia

    International Nuclear Information System (INIS)

    Yamamoto, Ryo; Shinozaki, Hiroharu; Kase, Kenichi; Kobayashi, Kenji; Sasaki, Junichi

    2012-01-01

    Femoral hernia is a surgical disease that is frequently associated with incarceration and necessitates emergency surgery. However, there are only a few studies referred which have compared emergency and elective surgery for femoral hernias. We retrospectively reviewed the clinical characteristics of patients diagnosed as having femoral hernia between 2005 and 2009 in our institution. The clinical features of emergency repairs were compared with those of elective ones, and diagnostic values of preoperative diagnostic modalities were studied. The mean age of the patients was 73±12 years. Females comprised 68% of the cases, and right femoral hernias comprised 70% of the cases. Incarceration was associated with 66% of the cases (29 patients), and emergency surgery was performed in 52% of the patients (23 patients). Bowel resection was performed in 32% of the cases (14 patients). The mean age, body temperature, white blood cell (WBC) count, and LDH value were higher in the emergency repairs than in the elective one, and most of the hernias were repaired with McVay's procedure. CT scans had a high diagnostic value in detecting femoral hernias (44%) and incarceration (88%). It was confirmed that femoral hernias were frequently associated with incarceration and CT scan has a high diagnostic value in femoral hernias. (author)

  17. Randomized Trial of the SMART Stent versus Balloon Angioplasty in Long Superficial Femoral Artery Lesions: The SUPER Study

    International Nuclear Information System (INIS)

    Chalmers, Nicholas; Walker, Paul T.; Belli, Anna-Maria; Thorpe, Anthony P.; Sidhu, Paul S.; Robinson, Graham; Ransbeeck, Mariella van; Fearn, Steven A.

    2013-01-01

    To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5–22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months’ follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.

  18. MR evaluation of femoral neck version and tibial torsion

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, James Karl; Dwek, Jerry R. [University of California, San Diego, Children' s Hospital and Health Center, Department of Radiology, San Diego, CA (United States); Pring, Maya E. [Rady Children' s Hospital, Department of Pediatric Orthopedic Surgery, San Diego, CA (United States)

    2012-01-15

    Abnormalities of femoral neck version have been associated with a number of hip abnormalities in children, including slipped capital femoral epiphysis, proximal femoral focal deficiency, coxa vara, a deep acetabulum and, rarely, developmental dysplasia of the hip. Orthopedic surgeons also are interested in quantifying the femoral neck anteversion or retroversion in children especially to plan derotational osteotomies. Historically, the angle of femoral version and tibial torsion has been measured with the use of radiography and later by CT. Both methods carry with them the risks associated with ionizing radiation. Techniques that utilize MR are used less often because of the associated lengthy imaging times. This article describes a technique using MRI to determine femoral neck version and tibial torsion with total scan times of approximately 10 min. (orig.)

  19. Aespoe Hard Rock Laboratory. The TASS-tunnel. Geological mapping

    Energy Technology Data Exchange (ETDEWEB)

    Hardenby, Carljohan (Vattenfall Power Consultant AB (Sweden)); Sigurdsson, Oskar (HAskGeokonsult AB (Sweden))

    2010-12-15

    The project entitled 'Sealing of tunnel at great depth' (Fintaetning av tunnel paa stort djup) needed a new tunnel in an area as undisturbed as possible and with cross-cutting water-bearing structures. The new tunnel, which was given the name TASS, was excavated on the -450 m level of SKB's Aespoe Hard Rock Laboratory (Aespoe HRL). The length of the tunnel is approximately 80 m and the theoretical tunnel area 19 m2. As is the case with all the other tunnels of the Aespoe HRL, the new tunnel has been geologically mapped. In addition, laser scanning combined with digital photography has been carried out. The tunnel was also used to test various types of explosives, borehole layouts and drilling techniques. The geological mapping of tunnel floor, walls and roof took place on four major occasions when a halt was made in tunnel excavation to allow for various tests. Before the mapping started on these occasions, laser scanning took place. The tunnel faces were mapped after each round (drilling, blasting and unloading). The present report describes the geological features of the tunnel and briefly how the laser scanning was performed. Water-bearing structures have been compared to similar structures in the neighbouring tunnels. The rock type names used here follow the old established Aespoe HRL nomenclature. Narrow (<0.1 m wide) dykes are normally mapped as fracture fillings. The dominating rock type is Aespoe diorite, which constitutes some 90 % of the rock mass. It is mostly mapped as fresh rock. . Minor constituents of the rock mass are fine-grained granite, hybrid rock, pegmatite, quartz veins/lenses and undifferentiated mafic rock. The mapping of fractures and deformation zones considers a number of parameters such as number of fractures, open/healed, width, length, description of fracture surfaces (roughness, planarity, etc), fracture filling, alteration and water. The deformation zones are discriminated into two main categories (&apos

  20. Aespoe Hard Rock Laboratory. The TASS-tunnel. Geological mapping

    International Nuclear Information System (INIS)

    Hardenby, Carljohan; Sigurdsson, Oskar

    2010-12-01

    The project entitled 'Sealing of tunnel at great depth' (Fintaetning av tunnel paa stort djup) needed a new tunnel in an area as undisturbed as possible and with cross-cutting water-bearing structures. The new tunnel, which was given the name TASS, was excavated on the -450 m level of SKB's Aespoe Hard Rock Laboratory (Aespoe HRL). The length of the tunnel is approximately 80 m and the theoretical tunnel area 19 m 2 . As is the case with all the other tunnels of the Aespoe HRL, the new tunnel has been geologically mapped. In addition, laser scanning combined with digital photography has been carried out. The tunnel was also used to test various types of explosives, borehole layouts and drilling techniques. The geological mapping of tunnel floor, walls and roof took place on four major occasions when a halt was made in tunnel excavation to allow for various tests. Before the mapping started on these occasions, laser scanning took place. The tunnel faces were mapped after each round (drilling, blasting and unloading). The present report describes the geological features of the tunnel and briefly how the laser scanning was performed. Water-bearing structures have been compared to similar structures in the neighbouring tunnels. The rock type names used here follow the old established Aespoe HRL nomenclature. Narrow (<0.1 m wide) dykes are normally mapped as fracture fillings. The dominating rock type is Aespoe diorite, which constitutes some 90 % of the rock mass. It is mostly mapped as fresh rock. . Minor constituents of the rock mass are fine-grained granite, hybrid rock, pegmatite, quartz veins/lenses and undifferentiated mafic rock. The mapping of fractures and deformation zones considers a number of parameters such as number of fractures, open/healed, width, length, description of fracture surfaces (roughness, planarity, etc), fracture filling, alteration and water. The deformation zones are discriminated into two main categories ('increased fracturing' and

  1. Correlation between baseline femoral neck marrow status and the development of femoral head osteonecrosis in corticosteroid-treated patients: A longitudinal study by MR imaging

    International Nuclear Information System (INIS)

    Vande Berg, Bruno C.; Gilon, Raphael; Malghem, Jacques; Lecouvet, Frederic; Depresseux, Genevieve; Houssiau, Frederic A.

    2006-01-01

    Objective: To test the hypothesis that the development of corticosteroid (CS)-associated femoral head osteonecrosis (ON) is influenced by baseline femoral neck marrow status. Patients and methods: The population consisted of 20 untreated patients with a newly diagnosed rheumatic disease in whom a standardized CS regimen was planned. Before CS treatment, baseline femoral neck marrow status was determined by magnetic resonance (MR) imaging on T1-weighted images (proportion of surface area of femoral neck and intertrochanteric area occupied by fatty marrow; index of marrow conversion [IMC]) and on a quantitative MR sequence (bulk T1 values of femoral head and neck). The presence of ON was assessed by coronal T1-weighted MR images of the hips at 6 and 12 months. Results: None of the patients suffered from ON at baseline. Four patients (20%) developed bilateral femoral head ON at 6 months. The mean percentage of fat marrow in the femoral neck before treatment was significantly higher in ON-positive than in ON-negative patients (p = 0.0025). The mean baseline femoral neck IMC value, which parallels the degree of red to yellow marrow conversion, was higher in ON-positive than in ON-negative patients (p = 0.089). The mean baseline bulk T1 value of the femoral neck (but not of the femoral head), which inversely correlates with the amount of fat marrow, was significantly shorter in ON-positive than in ON-negative patients (p = 0.0298). Conclusion: The development of CS-associated femoral head ON is correlated with a high fat content in the proximal femur before CS therapy

  2. Subintimal angioplasty for the treatment of long segment occlusion of superficial femoral artery: the midterm results

    International Nuclear Information System (INIS)

    Lou Wensheng; Gu Jianping; He Xu; Chen Liang; Chen Guoping; Su Haobo; Song Jinhua; Wang Tao; Xu Ke

    2011-01-01

    Objective: To discuss the clinical value of subintimal angioplasty in treating long segment occlusion of superficial femoral artery and to observe its midterm results. Methods: Subintimal angioplasty was performed in 45 patients with long segment occlusion of superficial femoral artery, whose clinical presentation was intermittent claudication or critical limb ischemia. The primary patency, limb salvage and factors influencing long-term patency were observed, and the clinical data were analyzed. Results: Of the total 45 cases, the subintimal angioplasty was successfully accomplished in 43. The success rate of antegrade approach technique via the superficial femoral artery was 80% (n=36), the occlusion was recanalized by using retrograde approach technique via ipsilateral popliteal artery in 7 case. The total technical success rate was 95.6%. The primary patency in 43 successful cases at 6, 12, 24 and 36 months was 85.7%, 69.0% 57.3% and 50.9%, respectively. No statistically significant difference in primary patency existed between the group of intermittent claudication and the group of critical limb ischemia (P>0.05). Statistically significant prediction factors for primary patency included the number of the run off vessels below the knee and the length of the occlusion (P<0.05). Conclusion: Subintimal angioplasty is an effective procedure for the treatment of long segment occlusions of superficial femoral artery with satisfactory mid-term results. (authors)

  3. Herniography off femoral, obturator and perineal hernias

    International Nuclear Information System (INIS)

    Ekberg, O.; Nordblom, I.; Fork, F.T.; Gullmo, A.

    1985-01-01

    Positive contrast herniography was used in the workup of 550 patients with unclear groin pain. The majority of these patients had rather characteristic hernias of indirect, direct or femoral type. However, now and then diagnostic problems arose. A femoral hernia may look like a direct or even obturator hernia. There is also a variety of multilocular femoral hernias and other types. A femoral hernia may be present together with other hernias in the ipsilateral or contralateral groin. Obturator hernias are usually small but are always confined to the obturator canal laterally in the obturator foramen. Abnormalities in the pouch of Douglas may include a deep rectogenital pouch, diverticula and true herniations. These uncommon herniographic findings are described and discussed. (orig.) [de

  4. Trochanteric entry femoral nails yield better femoral version and lower revision rates-A large cohort multivariate regression analysis.

    Science.gov (United States)

    Yoon, Richard S; Gage, Mark J; Galos, David K; Donegan, Derek J; Liporace, Frank A

    2017-06-01

    Intramedullary nailing (IMN) has become the standard of care for the treatment of most femoral shaft fractures. Different IMN options include trochanteric and piriformis entry as well as retrograde nails, which may result in varying degrees of femoral rotation. The objective of this study was to analyze postoperative femoral version between three types of nails and to delineate any significant differences in femoral version (DFV) and revision rates. Over a 10-year period, 417 patients underwent IMN of a diaphyseal femur fracture (AO/OTA 32A-C). Of these patients, 316 met inclusion criteria and obtained postoperative computed tomography (CT) scanograms to calculate femoral version and were thus included in the study. In this study, our main outcome measure was the difference in femoral version (DFV) between the uninjured limb and the injured limb. The effect of the following variables on DFV and revision rates were determined via univariate, multivariate, and ordinal regression analyses: gender, age, BMI, ethnicity, mechanism of injury, operative side, open fracture, and table type/position. Statistical significance was set at pregression analysis revealed that a lower BMI was significantly associated with a lower DFV (p=0.006). Controlling for possible covariables, multivariate analysis yielded a significantly lower DFV for trochanteric entry nails than piriformis or retrograde nails (7.9±6.10 vs. 9.5±7.4 vs. 9.4±7.8°, pregression analysis. However, this is not to state that the other nail types exhibited abnormal DFV. Translation to the clinical impact of a few degrees of DFV is also unknown. Future studies to more in-depth study the intricacies of femoral version may lead to improved technology in addition to potentially improved clinical outcomes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Limb shortening osteotomy in a patient with achondroplasia and leg length difference after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Christian L. Galata

    2013-07-01

    Full Text Available Introduction: Achondroplasia is the most common reason for disproportionate short stature. Normally, orthopedic limb lengthening procedures must be discussed in the course of this genetic disorder and have been successful in numerous achondroplastic patients in the past. In some cases, the disease may lead to leg length differences with need for surgical correction. Case Report: We report a case of achondroplastic dysplastic coxarthrosis with symptomatic leg length difference after bilateral total hip arthroplasty in a 52-year-old female patient, in which a distal femoral shortening osteotomy was successfully performed. Conclusion: Femoral shortening osteotomy is very uncommon in patients with achondroplasia. We conclude, however, that in rare cases it can be indicated and provide the advantage of shorter operation time, less perioperative complications and faster recovery compared to leg lengthening procedures. Keywords: Achondroplasia, dysplastic coxarthrosis, limb shortening, distal femur osteotomy.

  6. The difference in centre position in the ACL femoral footprint inclusive and exclusive of the fan-like extension fibres.

    Science.gov (United States)

    Iriuchishima, Takanori; Ryu, Keinosuke; Aizawa, Shin; Fu, Freddie H

    2016-01-01

    The purpose of this study was to compare the centre position of each anterior cruciate ligament bundle in its femoral footprint in measurements including and excluding the fan-like extension fibres. Fourteen non-paired human cadaver knees were used. All soft tissues around the knee were resected except the ligaments. The ACL was divided into antero-medial (AM) and postero-lateral (PL) bundles according to the difference in tension patterns. The ACL was carefully dissected, and two outlines were made of the periphery of each bundle insertion site: those which included and those which excluded the fan-like extension fibres. An accurate lateral view of the femoral condyle was photographed with a digital camera, and the images were downloaded to a personal computer. The centre position of each bundle, including and excluding the fan-like extension fibres, was measured with ImageJ software (National Institution of Health). Evaluation of the centre position was performed using the modified quadrant method. The centre of the femoral AM bundle including the fan-like extension was located at 28.8% in a shallow-deep direction and 37.2% in a high-low direction. When the AM bundle was evaluated without the fan-like extension, the centre was significantly different at 34.6% in a shallow-deep direction (p = 0.000) and 36% in a high-low direction. The centre of the PL bundle including the fan-like extension was found at 37.1% in a shallow-deep direction and 73.4% in a high-low direction. When the PL bundle was evaluated without the fan-like extension, the centre was significantly different at 42.7% in a shallow-deep direction (p = 0.000) and 69.3% in a high-low direction (p = 0.000). The centre position of the AM and PL bundles in the femoral ACL footprint was significantly different depending on the inclusion or exclusion of the fan-like extension fibres. For the clinical relevance, to reproduce the direct femoral insertion in the anatomical ACL reconstruction, tunnels should be

  7. Bilateral femoral neck fractures following pelvic irradiation

    International Nuclear Information System (INIS)

    Mitsuda, Kenji; Nishi, Hosei; Oba, Hiroshi

    1977-01-01

    Over 300 cases of femoral neck fractures following radiotherapy for intrapelvic malignant tumor have been reported in various countries since Baensch reported this disease in 1927. In Japan, 40 cases or so have been reported, and cases of bilateral femoral neck fractures have not reached to ten cases. The authors experienced a case of 75 year-old female who received radiotherapy for cancer of the uterus, and suffered from right femoral neck fracture 3 months after and left femoral neck fracture one year and half after. As clinical symptoms, she had not previous history of trauma in bilateral femurs, but she complained of a pain in a hip joint and of gait disturbance. The pain in left femoral neck continued for about one month before fracture was recognized with roentgenogram. As histopathological findings, increase of fat marrow, decrease of bone trabeculae, and its marked degeneration were recognized. Proliferation of some blood vessels was found out, but thickness of the internal membrane and thrombogenesis were not recognized. Treatment should be performed according to degree of displacement of fractures. In this case, artificial joint replacement surgery was performed to the side of fracture of this time, because this case was bilateral femoral neck fractures and the patient had received artificial head replacement surgery in the other side of fracture formerly. (Tsunoda, M.)

  8. [Treatment of avascular necrosis of femoral head after femoral neck fracture with pedicled iliac bone graft].

    Science.gov (United States)

    Wang, Benjie; Zhao, Dewei; Guo, Lin; Yang, Lei; Li, Zhigang; Cui, Daping; Tian, Fengde; Liu, Baoyi

    2011-05-01

    To explore the effectiveness of pedicled iliac bone graft transposition for treatment of avascular necrosis of femoral head (ANFH) after femoral neck fracture. Between June 2002 and December 2006, 22 cases (22 hips, 16 left hips and 6 right hips) of ANFH after femoral neck fracture were treated with iliac bone graft pedicled with ascending branch of the lateral femoral circumflex vessels. There were 18 males and 4 females with an age range from 28 to 48 years (mean, 37.5 years). The time from injury to internal fixation was 2-31 days, and all fractures healed within 12 months after internal fixation. The ANFH was diagnosed at 15-40 months (mean, 22 months) after internal fixation. The ANFH duration was 3-11 months (mean, 8 months). According to Association Research Circulation Osseous (ARCO) staging system, 2 hips were classified as stage IIa, 3 hips as stage IIb, 3 hips as stage IIc, 3 hips as stage IIIa, 7 hips as stage IIIb, and 4 hips as stage IIIc. The preoperative Harris hip score (HHS) was 64.10 +/- 5.95. All incisions healed by first intention and the patients had no complication of lung embolism, sciatic nerve injury, lower limb deep venous thrombosis, and numbness and pain of donor site. All patients were followed up 2.5 to 6.3 years (mean, 4.8 years). The fracture healing time was 8-12 months, and no femoral neck fracture recurred. The HHS was 90.20 +/- 5.35 at last follow-up, showing significant difference when compared with the preoperative value (t = -18.447, P = 0.000). The hip function were excellent in 11 hips, good in 10 hips, fair in 1 hip, and the excellent and good rate was 95.5%. Four hips were radiographically progressed in ARCO staging, 18 hips remained stable with a stable rate of 81.8%. Pedicled iliac bone graft transposition is an ideal option for treatment of ANFH after internal fixation of femoral neck fracture for the advantages of femoral head revascularization, sufficient cancellous bone supply, and relatively simple procedure.

  9. Magnetic resonance imaging of the femoral head necrosis

    Energy Technology Data Exchange (ETDEWEB)

    Narita, Shinya; Asada, Kanji; Yoshida, Kenjiro and others

    1986-06-01

    Ten patients with avascular femoral head necrosis and four normal adults were examined by magnetic resonance imaging (MRI). In addition, the relationship between MRI and pathophysiology of three operated-on avascular femoral heads was evaluated. The medullary cavities of the normal femoral heads had a strong signal intensity on the saturation recovery (SR) image due to fat marrow, and the T/sub 1/ relaxation time was 160 +- 11 msec. In avascular femoral head necrosis, the necrotic area had a low signal intensity on the SR image and a prolonged T/sub 1/ relaxation time, while the reactive fibrous area had more prolonged T/sub 1/ relaxation time. For these reasons, MRI was found to show the pathological changes of avascular femoral head necrosis and can be expected to be useful for making early diagnoses and operation planning.

  10. Magnetic resonance imaging of the femoral head necrosis

    International Nuclear Information System (INIS)

    Narita, Shinya; Asada, Kanji; Yoshida, Kenjiro

    1986-01-01

    Ten patients with avascular femoral head necrosis and four normal adults were examined by magnetic resonance imaging (MRI). In addition, the relationship between MRI and pathophysiology of three operated-on avascular femoral heads was evaluated. The medullary cavities of the normal femoral heads had a strong signal intensity on the saturation recovery (SR) image due to fat marrow, and the T 1 relaxation time was 160 ± 11 msec. In avascular femoral head necrosis, the necrotic area had a low signal intensity on the SR image and a prolonged T 1 relaxation time, while the reactive fibrous area had more prolonged T 1 relaxation time. For these reasons, MRI was found to show the pathological changes of avascular femoral head necrosis and can be expected to be useful for making early diagnoses and operation planning. (author)

  11. Correlation of intra-articular osseous measurements with posterior cruciate ligament length on MRI scans.

    LENUS (Irish Health Repository)

    Orakzai, S H

    2010-01-01

    Six patients with a clinical diagnosis of chronic posterior cruciate ligament (PCL) rupture, based on a positive posterior drawer test, had a normal appearance of the PCL on an MRI scan. It is postulated that the PCL had been ruptured but healed in a lengthened state. 12 volunteers with no history of knee trauma underwent an MRI scan of the knee. In this control group (n = 12), there was a close correlation between the lateral femoral condylar width in the sagittal plane and the PCL length, with a ratio of 2:1 (95% confidence interval (CI) = 1.817-2.095). In the clinically abnormal group (n = 6), the ratio was 1.49:1 (95% CI = 1.206-1.782) (p< 0.0005). In conclusion, the ratio of the lateral femoral condylar width in the sagittal plane to the PCL length is a useful index for diagnosing PCL attenuation and lengthening in the presence of a normal morphological MR appearance.

  12. Femoral component loosening after hip resurfacing arthroplasty

    International Nuclear Information System (INIS)

    Zustin, Jozef; Sauter, Guido; Hahn, Michael; Morlock, Michael M.; Ruether, Wolfgang; Amling, Michael

    2010-01-01

    Before the re-introduction of the current generation of total hip resurfacing arthroplasty, component loosening and osteolysis were of great concern to the orthopaedic community. Early, mid- and long-term clinical results are encouraging, but component loosening still exists. Macroscopic, contact radiographic and histopathological analyses after undecalcified preparation of bone tissue specimens were performed. To investigate the frequency and morphological patterns of the loosening of the femoral component, we analysed a series of 190 retrieved femoral remnants that were revised for aseptic failures. Thirty-five (18.4%) hips were revised for clinical and/or radiographic loosening of the femoral component. Pseudoarthrosis (n = 17; median in situ time: 16 weeks, interquartile range [IQR]: 9 to 34), collapsed osteonecrosis (n = 5; median in situ time: 79 weeks, IQR: 63 to 97), cement-socket debonding (n = 3; median in situ time: 89 weeks, IQR: 54 to 97) and at later follow-up bone-cement loosening (n = 10; median in situ time: 175 weeks; IQR 112 to 198; p =0.005) were distinct patterns of the femoral remnant-implant loosening. Fibrocartilaginous metaplasia of interface bone trabeculae (n = 38; median in situ time: 61 weeks, IQR: 32 to 138) was strongly associated with femoral component loosening (p = 0.009). Both the trabecular hyperosteoidosis (n = 32; median in situ time: 71 weeks, IQR 50 to 129) and excessive intraosseous lymphocyte infiltration (n = 12; median in situ time: 75 weeks, IQR 51 to 98) at the bone-cement interface correlated strongly with fibrocartilaginous metaplasia (p = 0.001 and p = 0.016 respectively) and all three lesions were associated with the female gender (p = 0.021, p = 0.009, and p = 0.051). Femoral component loosening at early follow-up was mostly caused by pathological changes of the femoral remnant bone tissue: pseudoarthrosis and collapsed osteonecrosis. Fibrocartilaginous metaplasia was frequently observed in hips with femoral

  13. Avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Kokubo, Takeshi; Takatori, Yoshio; Kamogawa, Morihide; Nakamura, Toshitaka; Ninomiya, Setsuo; Yoshikawa, Kohki; Itai, Yuji; Iio, Masahiro; Mitamura, Tadayuki

    1990-01-01

    T1-weighted MR images of thirty-six hips in 25 patients with avascular necrosis of the femoral head were obtained two to five times during the course of 2 to 26 months. We investigated these MR images in the light of the chronological change and compared them with plain radiographs. MR images changes in 16 femoral head; in general, the abnormal low intensity area in the femoral head reduced in extent and the internal high intensity area became smaller of disappeared. Thirteen femoral heads among them became more flattened on plain radiographs in the same period. It is noted that four different zones are defined in the femoral head after bone necrosis takes place: the dead bone marrow, the dead marrow which still contains fat, the reactive interface and the hyperemic bone marrow. In T1-weighted MR images, the dead bone marrow, the reactive interface and the hyperemic bone marrow are demonstrated as low intensity area, while the dead marrow containing fat may remain high in intensity. On the basis of this knowledge of histopathology and MR images of this disease, we suggest that reduction of the abnormal low intensity area and disappearance of the internal high intensity area on MR images can be regarded as diminution of hyperemia in the living bone marrow and loss of fat in the dead bone marrow, respectively. (author)

  14. Quantum tunneling of massive flux lines in a high-T{sub c} superconductor

    Energy Technology Data Exchange (ETDEWEB)

    Gaber, M.W.; Achar, B.N.N. [Memphis Univ., TN (United States)

    1999-02-01

    We have investigated the quantum tunneling of damped flux lines of finite mass at T = 0 by extending our previous study of tunneling around T{sub 0}, the transition temperature. In the case of a cubic pinning potential, considered here, the action could be evaluated in a closed form for a flux line of finite length. The tunneling rate reaches a finite limit at T = 0, although it is temperature dependent and exhibits a 1/T variation near T{sub 0}. (orig.) 21 refs.

  15. Experience in design and construction of the Log tunnel

    Directory of Open Access Journals (Sweden)

    Jovičić Vojkan

    2017-09-01

    Full Text Available A twin highway Log tunnel is a part of a new motorway connection between Maribor and Zagreb, section Draženci-Gruškovje, which is located towards the border crossing between Slovenia and Croatia. The tunnel is currently under construction, and only the excavation works have been completed during the writing of this paper. The terrain in the area of the Log tunnel is diverse, and the route of the highway in its vicinity is characterised by deep excavations, bridges or viaducts. The Log tunnel is approximately 250 m long, partly constructed as a gallery. The geological conditions are dominated by Miocene base rock, featuring layers of well-connected clastic rocks, which are covered by diluvium clays, silts, sands and gravels of different thicknesses. Due to the short length of the tunnel, the usual separation of the motorway route to the left and the right tunnel axes was not carried out. Thus, the tunnel was constructed with an intermediate pillar and was designed as a three-lane tunnel, including the stopping lane. The construction of the tunnel was carried out using the New Austrian tunnelling method (NATM, in which the central adit was excavated first and the intermediate pillar was constructed within it. The excavation of the main tubes followed and was divided into the top heading, bench and the invert, enabling the intermediate pillar to take the load off the top heading of both tubes. The secondary lining of the tunnel is currently under construction. The experience of the tunnel construction gathered so far is presented in the paper. The main emphasis is on the construction of the intermediate pillar, which had to take the significant and asymmetrical ground load.

  16. Experience in design and construction of the Log tunnel

    Science.gov (United States)

    Jovičić, Vojkan; Goleš, Niko; Tori, Matija; Peternel, Miha; Vajović, Stanojle; Muhić, Elvir

    2017-09-01

    A twin highway Log tunnel is a part of a new motorway connection between Maribor and Zagreb, section Draženci-Gru\\vskovje, which is located towards the border crossing between Slovenia and Croatia. The tunnel is currently under construction, and only the excavation works have been completed during the writing of this paper. The terrain in the area of the Log tunnel is diverse, and the route of the highway in its vicinity is characterised by deep excavations, bridges or viaducts. The Log tunnel is approximately 250 m long, partly constructed as a gallery. The geological conditions are dominated by Miocene base rock, featuring layers of well-connected clastic rocks, which are covered by diluvium clays, silts, sands and gravels of different thicknesses. Due to the short length of the tunnel, the usual separation of the motorway route to the left and the right tunnel axes was not carried out. Thus, the tunnel was constructed with an intermediate pillar and was designed as a three-lane tunnel, including the stopping lane. The construction of the tunnel was carried out using the New Austrian tunnelling method (NATM), in which the central adit was excavated first and the intermediate pillar was constructed within it. The excavation of the main tubes followed and was divided into the top heading, bench and the invert, enabling the intermediate pillar to take the load off the top heading of both tubes. The secondary lining of the tunnel is currently under construction. The experience of the tunnel construction gathered so far is presented in the paper. The main emphasis is on the construction of the intermediate pillar, which had to take the significant and asymmetrical ground load.

  17. CT study of avascular necrosis of femoral head in adults

    International Nuclear Information System (INIS)

    Liu Jihua; Du Yuqing; Xu Aide

    2000-01-01

    Objective: To study the early and new CT signs of avascular necrosis of femoral head in adults. Methods: The CT scans of 127 cases with this condition were analyzed. Results: There were 90 hip joints with femoral head normal in shape, including 67 femoral heads with only high-density sclerosis and 23 ones with high-density and low-density areas. In 111 hip joints, the femoral head was depressed and manifested purely high-density sclerosis in 25 and mixed-density areas in 86. Air-filled cysts appeared in 43 femoral heads. In follow-up cases, the changes in shape and density of femoral head followed some rules. Conclusion: Purely high-density sclerosis is an early sign and is of great diagnostic value combined with its special shape. Air in femoral heads is also a sign of the disease

  18. Injection sealing of the TASS tunnel. Progress report

    International Nuclear Information System (INIS)

    Funehag, Johan

    2008-12-01

    SKB's disposal facility is planned to be located approx. 400-500 m deep and the demands of its water tightness will be very high. The plant will be located in relatively fault-free rock with limited discharge and sealing will be carried out by injection. Given the very fine cracks that need to be sealed and the strong desire to use an injection material which generate a leachate with a pH lower than 11, SKB performs studies of silica sol and cement-based mortar with low pH in order to be able to use these in the sealing works. In the sealing project a 100 m long tunnel is constructed, the TASS tunnel at a depth of 450 min at SKB's rock laboratory on Aespoe. This report includes the results obtained until September 2008. At this date the injection stages 1, 2, and half of stage 3 have been done and preparation for Stage 3 is ongoing. The tunnel has reached a length of 55.5 m and the results from leaching measurements exist for stage 2 (Section 10-34 m). Both cement-based mortar with low pH and silica sol has been used, but cement-based mortar has been used only in relatively small scale. The cement-based mortar is developed especially for the repository. Silica sol used a particle size of about 25 nm and accelerator in the form of sodium chloride. The limit for inward leakage in the tunnel is 1 l/min and 60 m tunnel. Groundwater pressure was found to be 3.0-3.5 MPa. Past results obtained from Stage 2 indicate that injection shields fulfil the rate requirement over a 23 meter distance. The control holes drilled in the screens have been used to gradually steer the injection and to demonstrate a direct sealing effect of the screens. A controllable gelation time is necessary for efficient and controllable injection. Used mixing procedure has been proven to work and intended gelation times have been achieved. The two cement-based mortar mixtures for crack injection used in the project are robust and have desirable properties. Design methodology linking borehole distance

  19. Switching between dynamic states in intermediate-length Josephson junctions

    DEFF Research Database (Denmark)

    Pagano, S.; Sørensen, Mads Peter; Parmentier, R. D.

    1986-01-01

    The appearance of zero-field steps (ZFS’s) in the current-voltage characteristics of intermediate-length overlap-geometry Josephson tunnel junctions described by a perturbed sine-Gordon equation (PSGE) is associated with the growth of parametrically excited instabilities of the McCumber backgroun...

  20. Femoral Component External Rotation Affects Knee Biomechanics: A Computational Model of Posterior-stabilized TKA.

    Science.gov (United States)

    Kia, Mohammad; Wright, Timothy M; Cross, Michael B; Mayman, David J; Pearle, Andrew D; Sculco, Peter K; Westrich, Geoffrey H; Imhauser, Carl W

    2018-01-01

    The correct amount of external rotation of the femoral component during TKA is controversial because the resulting changes in biomechanical knee function associated with varying degrees of femoral component rotation are not well understood. We addressed this question using a computational model, which allowed us to isolate the biomechanical impact of geometric factors including bony shapes, location of ligament insertions, and implant size across three different knees after posterior-stabilized (PS) TKA. Using a computational model of the tibiofemoral joint, we asked: (1) Does external rotation unload the medial collateral ligament (MCL) and what is the effect on lateral collateral ligament tension? (2) How does external rotation alter tibiofemoral contact loads and kinematics? (3) Does 3° external rotation relative to the posterior condylar axis align the component to the surgical transepicondylar axis (sTEA) and what anatomic factors of the femoral condyle explain variations in maximum MCL tension among knees? We incorporated a PS TKA into a previously developed computational knee model applied to three neutrally aligned, nonarthritic, male cadaveric knees. The computational knee model was previously shown to corroborate coupled motions and ligament loading patterns of the native knee through a range of flexion. Implant geometries were virtually installed using hip-to-ankle CT scans through measured resection and anterior referencing surgical techniques. Collateral ligament properties were standardized across each knee model by defining stiffness and slack lengths based on the healthy population. The femoral component was externally rotated from 0° to 9° relative to the posterior condylar axis in 3° increments. At each increment, the knee was flexed under 500 N compression from 0° to 90° simulating an intraoperative examination. The computational model predicted collateral ligament forces, compartmental contact forces, and tibiofemoral internal/external and

  1. Clavicular bone tunnel malposition leads to early failures in coracoclavicular ligament reconstructions.

    Science.gov (United States)

    Cook, Jay B; Shaha, James S; Rowles, Douglas J; Bottoni, Craig R; Shaha, Steven H; Tokish, John M

    2013-01-01

    Modern techniques for the treatment of acromioclavicular (AC) joint dislocations have largely centered on free tendon graft reconstructions. Recent biomechanical studies have demonstrated that an anatomic reconstruction with 2 clavicular bone tunnels more closely matches the properties of native coracoclavicular (CC) ligaments than more traditional techniques. No study has analyzed tunnel position in regard to risk of early failure. To evaluate the effect of clavicular tunnel position in CC ligament reconstruction as a risk of early failure. Case series; Level of evidence, 4. A retrospective review was performed of a consecutive series of CC ligament reconstructions performed with 2 clavicular bone tunnels and a free tendon graft. The population was largely a young, active-duty military group of patients. Radiographs were analyzed for the maintenance of reduction and location of clavicular bone tunnels using a picture archiving and communication system. The distance from the lateral border of the clavicle to the center of each bone tunnel was divided by the total clavicular length to establish a ratio. Medical records were reviewed for operative details and functional outcome. Failure was defined as loss of intraoperative reduction. The overall failure rate was 28.6% (8/28) at an average of 7.4 weeks postoperatively. Comparison of bone tunnel position showed that medialized bone tunnels were a significant predictor for early loss of reduction for the conoid (a ratio of 0.292 vs 0.248; P = .012) and trapezoid bone tunnels (a ratio of 0.171 vs 0.128; P = .004); this correlated to an average of 7 to 9 mm more medial in the reconstructions that failed. Reconstructions performed with a conoid ratio of ≥0.30 were significantly more likely to fail (5/5, 100%) than were those performed lateral to a ratio of 0.30 (3/23, 13.0%) (P < .01). There were no failures when the conoid ratio was <0.25 (0/10, 0%). Conoid tunnel placement was also statistically significant for

  2. Tunneling technologies for the collider ring tunnels

    International Nuclear Information System (INIS)

    Frobenius, P.

    1989-01-01

    The Texas site chosen for the Superconducting Super Collider has been studied, and it has been determined that proven, conventional technology and accepted engineering practice are suitable for constructing the collider tunnels. The Texas National Research Laboratory Commission report recommended that two types of tunneling machines be used for construction of the tunnels: a conventional hard rock tunnel boring machine (TBM) for the Austin chalk and a double shielded, rotary TBM for the Taylor marl. Since the tunneling machines usually set the pace for the project, efficient planning, operation, and coordination of the tunneling system components will be critical to the schedule and cost of the project. During design, tunneling rate prediction should be refined by focusing on the development of an effective tunneling system and evaluating its capacity to meet or exceed the required schedules. 8 refs., 13 figs

  3. Study of the anatomical position of the femoral nerve by magnetic resonance imaging in patients with fractured neck of femur: relevance to femoral nerve block.

    LENUS (Irish Health Repository)

    Mehmood, Shehzad

    2012-01-31

    STUDY OBJECTIVE: To determine the anatomical location of the femoral nerve in patients who have sustained fracture of the neck of femur, and its relevance to femoral nerve block technique. DESIGN: Prospective, observational clinical study. SETTING: Orthopedic and Radiology departments of a regional hospital. SUBJECTS: 10 consecutive adult ASA physical status II and III patients (mean age, 78.5 yrs) and 4 adult healthy volunteers. INTERVENTIONS: A T1 magnetic resonance imaging scan was performed of both upper thighs in patients and healthy volunteers successfully. MEASUREMENTS: The distance (mm) between the midpoint of the femoral artery and the midpoint of the femoral nerve, and the distance of the femoral nerve from the skin was measured at the mid-inguinal ligament, the pubic tubercle, and at the mid-inguinal crease. Data are shown as means (SD). Differences between both sides were compared using paired Student\\'s t-tests. P < 0.05 was significant. MAIN RESULTS: In patients the mean distance (mm) between the midpoint of the femoral nerve from the midpoint of femoral artery at the mid-inguinal crease on the fractured and non-fractured sides was 10.7 and 11.0, respectively (P = 0.87). The mean distance (mm) between the midpoint of the femoral nerve from the midpoint of the femoral artery at the mid-inguinal ligament on the fractured and non-fractured sides was 9.64 and 12.5, respectively (P = 0.03). The mean distance (mm) between the midpoint of the femoral nerve from the midpoint of the femoral artery at the pubic tubercle on the fractured and non-fractured sides was 8.74 and 10.49, respectively (P = 0.18). CONCLUSIONS: Blockade of the femoral nerve may be easier to perform at the mid-inguinal crease in patients with fractured neck of femur.

  4. Bone tunnel diameter measured with CT after anterior cruciate ligament reconstruction using double-bundle auto-hamstring tendors: Clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Soo Jeong; Yoon, Young Cheol; Bae, So Young; Wang, Joon Ho [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-12-15

    To evaluate the correlation between bone tunnel diameter after anterior cruciate ligament (ACL) reconstruction measured by computed tomography (CT) using multiplanar reconstruction (MPR) and stability or clinical scores. Forty-seven patients (41 men and 6 women, mean age: 34 years) who had undergone ACL reconstruction with the double bundle technique using auto-hamstring graft and had subsequently received CT scans immediately after the surgery (T1: range, 1-4 days, mean, 2.5 days) and at a later time (T2: range, 297-644 days, mean, 410.4 days) were enrolled in this study. The diameter of each tunnel (two femoral and two tibial) at both T1 and T2 were independently measured using MPR technique by two radiologists. Stability and clinical scores were evaluated with a KT-2000 arthrometer, International Knee Documentation Committee objective scores, and the Lysholm score. Statistical analysis of the correlation between the diameter at T2 or the interval diameter change ratio ([T2 - T1] / T1) and clinical scores or stability was investigated. The tibial bone tunnels for the anteromedial bundles were significantly widened at T2 compared with T1 (observer 1, 0.578 mm to 0.698 mm, p value of < 0.001; observer 2, 0.581 mm to 0.707 mm, p value of < 0.001). There was no significant correlation between the diameter at T2 and stability or clinical scores and between the interval change ratio ([T2 - T1] / T1) and stability or clinical scores (corrected p values for all were 1.0). Intraobserver agreement for measurements was excellent (> 0.8) for both observers. Interobserver agreement for measurement was excellent (> 0.8) except for the most distal portion of the femoral bone tunnel for anterior medial bundle in immediate postoperative CT, which showed moderate agreement (concordance correlation coefficient = 0.6311).Neither the diameter nor its change ratio during interval follow-up is correlated with stability or clinical scores.

  5. Bone tunnel diameter measured with CT after anterior cruciate ligament reconstruction using double-bundle auto-hamstring tendors: Clinical implications

    International Nuclear Information System (INIS)

    Yoon, Soo Jeong; Yoon, Young Cheol; Bae, So Young; Wang, Joon Ho

    2015-01-01

    To evaluate the correlation between bone tunnel diameter after anterior cruciate ligament (ACL) reconstruction measured by computed tomography (CT) using multiplanar reconstruction (MPR) and stability or clinical scores. Forty-seven patients (41 men and 6 women, mean age: 34 years) who had undergone ACL reconstruction with the double bundle technique using auto-hamstring graft and had subsequently received CT scans immediately after the surgery (T1: range, 1-4 days, mean, 2.5 days) and at a later time (T2: range, 297-644 days, mean, 410.4 days) were enrolled in this study. The diameter of each tunnel (two femoral and two tibial) at both T1 and T2 were independently measured using MPR technique by two radiologists. Stability and clinical scores were evaluated with a KT-2000 arthrometer, International Knee Documentation Committee objective scores, and the Lysholm score. Statistical analysis of the correlation between the diameter at T2 or the interval diameter change ratio ([T2 - T1] / T1) and clinical scores or stability was investigated. The tibial bone tunnels for the anteromedial bundles were significantly widened at T2 compared with T1 (observer 1, 0.578 mm to 0.698 mm, p value of < 0.001; observer 2, 0.581 mm to 0.707 mm, p value of < 0.001). There was no significant correlation between the diameter at T2 and stability or clinical scores and between the interval change ratio ([T2 - T1] / T1) and stability or clinical scores (corrected p values for all were 1.0). Intraobserver agreement for measurements was excellent (> 0.8) for both observers. Interobserver agreement for measurement was excellent (> 0.8) except for the most distal portion of the femoral bone tunnel for anterior medial bundle in immediate postoperative CT, which showed moderate agreement (concordance correlation coefficient = 0.6311).Neither the diameter nor its change ratio during interval follow-up is correlated with stability or clinical scores

  6. Avascular osteonecrosis of the femoral condyle after arthroscopic surgery; Osteonecrose aseptique du condyle femoral apres meniscectomie par voie arthroscopique

    Energy Technology Data Exchange (ETDEWEB)

    Al-Kaar, M.; Garcia, J. [Hopital Cantonal Geneve, Geneva (Switzerland); Fritschy, D.; Bonvin, J.C. [Policlinique de Chirurgie, Hopital Cantonal Universitaire, Geneve (Switzerland)

    1997-04-01

    Avascular osteonecrosis of the femoral condyle after arthroscopic surgery. Retrospective review of 10 patients who presented with avascular necrosis of the ipsilateral femoral condyle following arthroscopic meniscectomy (9 medial, 1 lateral). The bone lesions were evaluated by radiography and MRI, which were repeated for few patients. MRI allows earlier diagnosis of avascular necrosis of the femoral condyle and offers an evaluation of extent of the lesions whose evolution is variable: 3 patients required a knee prosthesis, the other 7 patients were treated medically. (authors). 21 refs.

  7. Ultrasound-guided block of sciatic and femoral nerves: an anatomical study.

    Science.gov (United States)

    Waag, Sonja; Stoffel, Michael H; Spadavecchia, Claudia; Eichenberger, Urs; Rohrbach, Helene

    2014-04-01

    The sheep is a popular animal model for human biomechanical research involving invasive surgery on the hind limb. These painful procedures can only be ethically justified with the application of adequate analgesia protocols. Regional anaesthesia as an adjunct to general anaesthesia may markedly improve well-being of these experimental animals during the postoperative period due to a higher analgesic efficacy when compared with systemic drugs, and may therefore reduce stress and consequently the severity of such studies. As a first step 14 sheep cadavers were used to establish a new technique for the peripheral blockade of the sciatic and the femoral nerves under sonographic guidance and to evaluate the success rate by determination of the colorization of both nerves after an injection of 0.5 mL of a 0.1% methylene blue solution. First, both nerves were visualized sonographically. Then, methylene blue solution was injected and subsequently the length of colorization was measured by gross anatomical dissection of the target nerves. Twenty-four sciatic nerves were identified sonographically in 12 out of 13 cadavers. In one animal, the nerve could not be ascertained unequivocally and, consequently, nerve colorization failed. Twenty femoral nerves were located by ultrasound in 10 out of 13 cadavers. In three cadavers, signs of autolysis impeded the scan. This study provides a detailed anatomical description of the localization of the sciatic and the femoral nerves and presents an effective and safe yet simple and rapid technique for performing peripheral nerve blocks with a high success rate.

  8. Simultaneous avascular necrosis of both medial and lateral femoral condyles

    International Nuclear Information System (INIS)

    Mansberg, R.

    2002-01-01

    Full text: Avascular necrosis (AVN) of a femoral condyle is a common orthopaedic condition. While both medial and lateral femoral condyles may be involved either singly or sequentially the simultaneous occurrence of AVN of both femoral condyles is extremely uncommon. A 57-year-old male is presented who developed the onset of severe left sided knee pain suddenly at rest. Plain and tomographic radiography was unremarkable and a bone scan was performed. Markedly increased vascularity was demonstrated in the left knee with intense osteoblastic activity in the left medial and femoral condyles more marked in the lateral femoral condyle. A diagnosis of AVN of both femoral condyles was made and a MRI exam was performed to confirm this unusual diagnosis. The MRI showed a diffuse increase in intensity bilaterally with subtle bony change in the subarticular bone consistent with AVN more marked in the left lateral femoral condyle. The patients' symptoms resolved with supportive treatment. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  9. Tunnel pressure waves - A smartphone inquiry on rail travel

    Science.gov (United States)

    Müller, Andreas; Hirth, Michael; Kuhn, Jochen

    2016-02-01

    When traveling by rail, you might have experienced the following phenomenon: The train enters a tunnel, and after some seconds a noticeable pressure change occurs, as perceived by your ears or even by a rapid wobbling of the train windows. The basic physics is that pressure waves created by the train travel down the tunnel, are reflected at its other end, and travel back until they meet the train again. Here we will show (i) how this effect can be well understood as a kind of large-scale outdoor case of a textbook paradigm, and (ii) how, e.g., a prediction of the tunnel length from the inside of a moving train on the basis of this model can be validated by means of a mobile phone measurement.

  10. Marrow pattern in the proximal femoral metaphysis of patients with osteonecrosis of femoral head and normal subjects: comparison on MR images

    International Nuclear Information System (INIS)

    Chun, Ho Jong; Park, Jeong Mi; Kim, Jee Young; Lim, Gye Yeon; Yang, Po Song; Kim, Euy Neyong; Kim, Choon Yul; Shinn, Kyung Sub

    1996-01-01

    To predict early risk of osteonecrosis of the femoral head by comparison of the bone marrow pattern of the proximal femoral metaphysis(PFM) in normal subjects and patients with osteonecrosis of the femoral head on T1-weighted magnetic resonance(MR) images. The authors retrospectively reviewed T1(TR 525/TE 25 msec) weighted coronal MR images of 67 hips with osteonecrosis and 65 normal hips in 39 patients with osteonecrosis of the femoral head and in 27 normal subjects. On the basis of bright signal intensity of fat, the proportion of remaining hematopoietic marrow in PFM was subdivided into 4 grades (0 to 3) by two radiologists. No evidence of remaining hematopoietic marrow was assigned grade 0, and grades 1, 2 and 3 represented scanty, moderate, and prominent hematopoietic marrow, respectively. Grades 0 and 1 were collectively defined as 'predominantly fatty', grades 2 and 3 as 'predominantly hematopoietic'. The frequency of the predominantly fatty marrow in PFM was analyzed in relation to three age groups (<25, 25-50, 50<) and both sexes. The overall frequency of predominantly fatty marrow in PFM was higher in hips with osteonecrosis than in normal hips (p<0.001). Especially in the male population under the age of 50, the frequency was apparently higher in hips with osteonecrosis, compared with normal hips (p<0.0001). However, the male population aged over 50 or female population showed no statistically significant difference in our series. In proximal femoral metaphysis with osteonecrosis of the femoral head, fatty marrow conversion occurs apparently earlier than in normal subject. T1-weighted MR imaging could therefore be useful in predicting early risk of osteonecrosis of the femoral head because of early fatty marrow conversion of the proximal femoral metaphysis

  11. A micro-architectural evaluation of osteoporotic human femoral heads to guide implant placement in proximal femoral fractures.

    Science.gov (United States)

    Jenkins, Paul J; Ramaesh, Rishikesan; Pankaj, Pankaj; Patton, James T; Howie, Colin R; Goffin, Jérôme M; Merwe, Andrew van der; Wallace, Robert J; Porter, Daniel E; Simpson, A Hamish

    2013-10-01

    The micro-architecture of bone has been increasingly recognized as an important determinant of bone strength. Successful operative stabilization of fractures depends on bone strength. We evaluated the osseous micro-architecture and strength of the osteoporotic human femoral head. 6 femoral heads, obtained during arthroplasty surgery for femoral neck fracture, underwent micro-computed tomography (microCT) scanning at 30 μm, and bone volume ratio (BV/TV), trabecular thickness, structural model index, connection density, and degree of anisotropy for volumes of interest throughout the head were derived. A further 15 femoral heads underwent mechanical testing of compressive failure stress of cubes of trabecular bone from different regions of the head. The greatest density and trabecular thickness was found in the central core that extended from the medial calcar to the physeal scar. This region also correlated with the greatest degree of anisotropy and proportion of plate-like trabeculae. In the epiphyseal region, the trabeculae were organized radially from the physeal scar. The weakest area was found at the apex and peripheral areas of the head. The strongest region was at the center of the head. The center of the femoral head contained the strongest trabecular bone, with the thickest, most dense trabeculae. The apical region was weaker. From an anatomical and mechanical point of view, implants that achieve fixation in or below this central core may achieve the most stable fixation during fracture healing.

  12. Charged Massive Particle’s Tunneling from Charged Nonrotating Microblack Hole

    Directory of Open Access Journals (Sweden)

    M. J. Soleimani

    2016-01-01

    Full Text Available In the tunneling framework of Hawking radiation, charged massive particle’s tunneling in charged nonrotating TeV-scale black hole is investigated. To this end, we consider natural cutoffs as a minimal length, a minimal momentum, and a maximal momentum through a generalized uncertainty principle. We focus on the role played by these natural cutoffs on the luminosity of charged nonrotating microblack hole by taking into account the full implications of energy and charge conservation as well as the backscattered radiation.

  13. Experimental investigations of the steady flow through an idealized model of a femoral artery bypass

    Directory of Open Access Journals (Sweden)

    Giurgea Corina

    2014-03-01

    Full Text Available The present paper presents the steps taken by the authors in the first stage of an experimental program within a larger national research project whose objective is to characterize the flow through a femoral artery bypass with a view to finding solutions for its optimization. The objective of the stage is to investigate by means of the PIV method the stationary flow through a bypass model with an idealized geometry. A bypass assembly which reunites the idealized geometry models of the proximal and distal anastomoses, and which respects the lengths of a femoral artery bypass was constructed on the basis of data for a real patient provided by medical investigations. With the aim of testing the model and the established experimental set-up with regard to their suitability for the assessment of the velocity field associated to the steady flow through the bypass, three zones that can restore the whole distal anastomosis were PIV investigated. The measurements were taken in the conditions of maintained inflow at the bypass entry of 0.9 l / min (Re = 600. The article presents comparatively the flow spectra and the velocity fields for each zone obtained in two situations: with the femoral artery completely occluded and completely open.

  14. Surgery for pathological proximal femoral fractures, excluding femoral head and neck fractures: resection vs. stabilisation.

    Science.gov (United States)

    Zacherl, Max; Gruber, Gerald; Glehr, Mathias; Ofner-Kopeinig, Petra; Radl, Roman; Greitbauer, Manfred; Vecsei, Vilmos; Windhager, Reinhard

    2011-10-01

    Pathological femoral head and neck fractures are commonly treated by arthroplasty. Treatment options for the trochanteric region or below are not clearly defined. The purpose of this retrospective, comparative, double-centre study was to analyse survival and influences on outcome according to the surgical technique used to treat pathological proximal femoral fractures, excluding fractures of the femoral head and neck. Fifty-nine patients with 64 fractures were operated up on between 1998 and 2004 in two tertiary referral centres and divided into two groups. One group (S, n = 33) consisted of patients who underwent intramedullary nailing alone, and the other group (R, n = 31) consisted of patients treated by metastatic tissue resection and reconstruction by means of different implants. Median survival was 12.6 months with no difference between groups. Surgical complications were higher in the R group (n = 7) vs. the S group (n = 3), with no statistically significant difference. Patients with surgery-related complications had a higher survival rate (p = 0.049), as did patients with mechanical implant failure (p = 0.01). Survival scoring systems did not correlate with actual survival. Resection of metastases in patients with pathological fractures of the proximal femur, excluding femoral head and neck fractures, has no influence on survival. Patients with long postoperative survival prognosis are at risk of implant-related complications.

  15. Femoral head vitality after intracapsular hip fracture

    International Nuclear Information System (INIS)

    Stroemqvist, B.

    1983-01-01

    Femoral head vitality before, during and at various intervals from the operation was determined by tetracycline labeling and/or 99 sp (m)Tc-MDP scintimetry. In a three-year follow-up, healing prognosis could be determined by scintimetry 3 weeks from operation; deficient femoral head vitality predicting healing complications and retained vitality predicting uncomplicated healing. A comparison between pre- and postoperative scintimetry indicated that further impairment of the femoral head vitality could be caused by the operative procedure, and as tetracycline labeling prior to and after fracture reduction in 370 fractures proved equivalent, it was concluded that the procedure of osteosynthesis probably was responsible for capsular vessel injury, using a four-flanged nail. The four-flanged nail was compared with a low-traumatic method of osteosynthesis, two hook-pins, in a prospective randomized 14 month study, and the postoperative femoral head vitality was significantly better in the hook-pin group. This was also clearly demonstrated in a one-year follow-up for the fractures included in the study. Parallel to these investigations, the reliability of the methods of vitality determination was found satisfactory in methodologic studies. For clinical purpose, primary atraumatic osteosynthesis, postoperative prognostic scintimetry and early secondary arthroplasty when indicated, was concluded to be the appropriate approach to femoral neck fracture treatment. (Author)

  16. Early detection by sup(99m)Tc-Sn-pyrophosphate scintigraphy of femoral head necrosis following medial femoral neck fractures

    International Nuclear Information System (INIS)

    Greiff, J.; Lanng, S.; Hoeilund-Carlsen, P.F.; Karle, A.K.; Uhrenholdt, A.

    1980-01-01

    A selected series of 24 patients with displaced medial femoral neck fracture, treated with closed reduction and osteosynthesis with cancellous bone screws (ASIF), were investigated. During an observation period of 6 to 26 months, serial hip joint scintigraphies were performed and compared with serial X-ray examinations. At the first scintigraphic examination performed on average 5-6 weeks after the fracture, two separate investigators found a decreased amount of activity or no activity in the femoral head of 10 and 8 patients, respectively. At the second scintigraphic examination performed on average 11.1 weeks after the fracture both investigators found no activity or a decreased amount of activity in 8 patients. This figure declined to 7 during the following period, because one patient with decreased activity was recorded as having normal activity 15 months after the fracture. These 7 patients all developed radiological signs of femoral head collapse on average 16.3 months after the fracture (range 5-26 months), whereas their scintigrams displayed decreased or absent tracer uptake on average 1.2 months after the fracture (P<0.01). None of the patients with initially normal or increased uptake later showed decreased or absent uptake during the study and none developed radiological collapse. It may be concluded that absent or decreased uptake of sup(99m)Tc-Sn-pyrophosphate in the femoral head following medial femoral neck fracture indicates femoral head necrosis and a high risk of late segmental collapse, whereas normal or increased uptake implying preserved blood supply means that late segmental collapse will probably never develop. (author)

  17. Breakthrough in current-in-plane tunneling measurement precision by application of multi-variable fitting algorithm

    DEFF Research Database (Denmark)

    Cagliani, Alberto; Østerberg, Frederik Westergaard; Hansen, Ole

    2017-01-01

    We present a breakthrough in micro-four-point probe (M4PP) metrology to substantially improve precision of transmission line (transfer length) type measurements by application of advanced electrode position correction. In particular, we demonstrate this methodology for the M4PP current-in-plane t......We present a breakthrough in micro-four-point probe (M4PP) metrology to substantially improve precision of transmission line (transfer length) type measurements by application of advanced electrode position correction. In particular, we demonstrate this methodology for the M4PP current......-in-plane tunneling (CIPT) technique. The CIPT method has been a crucial tool in the development of magnetic tunnel junction (MTJ) stacks suitable for magnetic random-access memories for more than a decade. On two MTJ stacks, the measurement precision of resistance-area product and tunneling magnetoresistance...

  18. ANATOMICAL STUDY OF THE MORPHOMETRY OF THE TIBIAL AND FEMORAL ATTACHMENT SITES OF THE POSTERIOR CRUCIATE LIGAMENT; Estudio anatómico de la morfometría de los sitios de inserción tibial y femoral del ligamento cruzado posterior.

    Directory of Open Access Journals (Sweden)

    Paul Inalegwu Iyaji

    2016-11-01

    Full Text Available , Although later isolated injuries cruciate of the ligament (PCL are managed through non-operative rehabilitation, reconstruction is becoming ITS anatomic increasingly important. This study Provides Information Regarding the position and variability of Its tibial attachment sites, dimensions of the femoral insertions, Between These Comparing males and females, and Between right and left knees. Thirty one cadaveric knees (15 right, 16 left from nine female and seven male cadavers ( mean age 77 years Were Examined. The PCL footprint Which was Identified from the mean length and width of the tibial anterolateral (AL and posteromedial (PM 8.7 and 10.9 mm Were bundles, and 7.3 and 13.44mm respectively. The mean length and width of the tibial footprint in males and females 10.2 and 10.3 mm Were, and 7.7 and 11.4 mm for the AL bundle and 8.2 and 14.2 mm and 12.9 mm and 6.7 for the PM bundle respectively. The mean anatomical position of the AL and 51.0% Were PM bundles and 50.0% of the mediolateral diameter of the tibial plateau. The mean lengths and widths of the PCL femoral attachment Were 9.4 mm and 12.8 for the AL bundle and 7.5 and 11.4 mm for the PM bundle, with the AL bundle attachment being Significantly larger (P = 0.034 in evils. No Difference between right and left knees Were Observed . The data presented here will aid in making decisions to Achieve Appropriate anatomic PCL reconstruction., Although isolated lesions of the posterior cruciate ligament (PCL are Treated by non-operative rehabilitation, anatomical reconstruction've Become increasingly important. This study Provides information on the position and variability of the binding sites of the tibia, the dimensions of the femoral insertions, Comparing them Between the sexes, and Between the right and left knee. They Were Examined thirty-one (15 right and 16 left knees of 9 women and 7 dead bodies of males (mean age 77 years. Brand LCP was Identified from the length and width

  19. Femoral Head Avascular Necrosis Is Not Caused by Arthroscopic Posterolateral Femoroplasty.

    Science.gov (United States)

    Rupp, Robert E; Rupp, Sasha N

    2016-05-01

    This study was conducted to identify the risk of avascular necrosis of the femoral head after arthroscopic femoroplasty extending to the posterolateral femoral neck, the source of the primary blood supply to the femoral head. Cam lesions of femoroacetabular impingement are typically anterior along the junction of the femoral head and neck. However, anatomic variations can involve the posterolateral vascular region of the femoral head and neck. Femoroplasty involving this vascular region can lead to injury to the blood supply to the femoral head, with subsequent avascular necrosis. If the posterolateral portion of the cam lesion is preserved, persistent femoroacetabular impingement may occur. A retrospective review identified 112 patients who underwent arthroscopic femoroplasty for femoroacetabular impingement over a 2-year period. Of these patients, 14 had femoroplasty that extended to the posterolateral femoral head. Of this group, 5 had undergone magnetic resonance imaging (MRI) after femoroplasty and the other 9 were contacted to undergo MRI of the hip to evaluate for avascular necrosis. A radiologist and the senior author evaluated all MRI scans specifically for avascular necrosis of the femoral head. All procedures were performed by the senior author. Mean age of the 14 patients (8 women and 6 men) with femoroplasty that extended into the posterolateral vascular region of the femoral head was 44 years (range, 23-69 years). All 14 patients underwent MRI evaluation of the affected hip a mean of 25 months (range, 7-44 months) after femoroplasty. No MRI scans showed evidence of avascular necrosis of the femoral head. Femoroplasty of the posterolateral vascular region of the femoral head is not associated with avascular necrosis. Patients with femoroacetabular impingement and a cam lesion extending to the posterolateral femoral head can undergo femoroplasty of this region without the development of avascular necrosis. [Orthopedics. 2016; 39(3):177-180.]. Copyright

  20. Selective arteriography in femoral head fractures

    Energy Technology Data Exchange (ETDEWEB)

    Mannella, P; Galeotti, R; Borrelli, M; Benea, G; Massari, L; Chiarelli, G M

    1986-01-01

    The choice between conservative and radical operation in case of femoral neck fractures is very important because it is the determining factor for a successfull therapy. In case of epiphysial necrosis, an endoprosthesis as well as an osteosynthesis will be carried out. Selective arteriography of the medical circumflex artery represents the most reliable study to establish, immediately after the fractures, the possible presence of a post-traumatic ischemic necrosis. Angiography, as a reliable diagnostic tool, has to be carried out in the most selective way and needs the image subtraction technique. The authors report their preliminary results on the reliability of angiography in the femoral epiphyseal ischemic necrosis diagnosed by comparing the results of angiography with the wood light test carried out on the surgically removed femoral head. 18 refs.

  1. [Femoral artery pseudoaneurysms encountered in orthopedics and traumatology].

    Science.gov (United States)

    Raherinantenaina, F; Rajaonanahary, T M A; Rakoto Ratsimba, H N

    2015-12-01

    Most published articles regarding orthopedic- and trauma-related femoral artery pseudoaneurysms (FAPs) are case reports in English. Reported cases are often associated with a literature review but actually provide little robust data. We wanted to summarize the current knowledge on diagnostic and therapeutic features of these FAPs. A new case of superficial FAP is described followed by a review of the literature. A bibliographic search was performed online (PubMed, ScinceDirect) from 1964 to 2015 using the descriptors "traumatic femoral pseudoaneurysm, orthopedic surgery, osteochondroma". A total of 64 cases of FAPs was analyzed. There were 50 men with an average age of 40.72±26.45 years old. The most common clinical presentation was painful swelling (34%). Arteriography was the commonest radiological investigation used (63%). The main etiologies were orthopedic injuries (47%), surgery of the upper thigh (30%) and femoral osteochondromas (23%). Arterial injuries included superficial femoral (47%) and profunda femoris artery (50%). The treatment was open surgery (56%) or endovascular repair (36%). Deep femoral artery and its branches were embolized (47%) or ligated (38%). Endovascular stenting was performed in 30% of posttraumatic FAPs. All FAPs relating to osteochondromas were repaired surgically. Postoperative courses were uneventful in 95% of patients. Endovascular embolization is preferred in management of postsurgical FAPs which have usually involved the deep femoral artery. Endovascular stenting graft may be proposed for posttraumatic FAPs, for which the superficial femoral trunk is the most often involved vessel. Surgical repair should be performed when endovascular stenting graft is not feasible. Surgical repair is mandatory for all FAPs secondary to traumatic exostoses. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  2. Callus features of regenerate fracture cases in femoral lengthening in achondroplasia

    International Nuclear Information System (INIS)

    Devmurari, Kamlesh N.; Song, Hae Ryong; Modi, Hitesh N.; Venkatesh, K.P.; Ju, Kim Seung; Song, Sang Heon

    2010-01-01

    We studied the callus features seen in cases of regenerate fracture in femoral lengthening using a monolateral fixator in achondroplasia to determine whether callus types and shapes can predict the probability of callus fracture. The radiographs of 28 cases of femoral lengthening in 14 patients, 14 cases of callus fracture, and 14 cases without callus fracture were retrospectively analyzed by four observers and classified into different shapes and types in concordance with the Ru Li classification. The average lengthening of 9.4 cm (range 7.5-11.8 cm) was achieved, which was 41% (range 30-55%) of the original length and the average timing of callus fracture was 470 days (range 440-545 days) after surgery in the callus fracture group. While the average lengthening of 9.1 cm (range 8-9.7 cm) was achieved, this was 30% (range 28-32%) of the original length in the group of patients without callus fracture. The callus was atypically shaped, there was a 48% average (range 30-72%) reduction of the callus width compared with the natural width of the femur, and a lucent pathway was present in all cases of regenerate fracture. A lucent pathway was seen in all fracture cases with concave, lateral, and atypical shapes, and there was more than 30% lengthening and 30% reduction of the callus width compared with the natural width of the femur, which are the warning signs for regenerate fractures. These signs help the surgeon to predict the outcome and guide him in planning for any additional interventions. The Ru Li classification is an effective method for the evaluation of the chance of callus fracture. (orig.)

  3. Callus features of regenerate fracture cases in femoral lengthening in achondroplasia

    Energy Technology Data Exchange (ETDEWEB)

    Devmurari, Kamlesh N.; Song, Hae Ryong; Modi, Hitesh N.; Venkatesh, K.P.; Ju, Kim Seung; Song, Sang Heon [Korea University Medical College, Institute for Rare Diseases and Department of Orthopedic Surgery, Seoul (Korea)

    2010-09-15

    We studied the callus features seen in cases of regenerate fracture in femoral lengthening using a monolateral fixator in achondroplasia to determine whether callus types and shapes can predict the probability of callus fracture. The radiographs of 28 cases of femoral lengthening in 14 patients, 14 cases of callus fracture, and 14 cases without callus fracture were retrospectively analyzed by four observers and classified into different shapes and types in concordance with the Ru Li classification. The average lengthening of 9.4 cm (range 7.5-11.8 cm) was achieved, which was 41% (range 30-55%) of the original length and the average timing of callus fracture was 470 days (range 440-545 days) after surgery in the callus fracture group. While the average lengthening of 9.1 cm (range 8-9.7 cm) was achieved, this was 30% (range 28-32%) of the original length in the group of patients without callus fracture. The callus was atypically shaped, there was a 48% average (range 30-72%) reduction of the callus width compared with the natural width of the femur, and a lucent pathway was present in all cases of regenerate fracture. A lucent pathway was seen in all fracture cases with concave, lateral, and atypical shapes, and there was more than 30% lengthening and 30% reduction of the callus width compared with the natural width of the femur, which are the warning signs for regenerate fractures. These signs help the surgeon to predict the outcome and guide him in planning for any additional interventions. The Ru Li classification is an effective method for the evaluation of the chance of callus fracture. (orig.)

  4. Comparison of 2 surgical techniques for reconstructing posterolateral corner of the knee: a cadaveric study evaluated by navigation system.

    Science.gov (United States)

    Ho, Eric Po-Yan; Lam, Mak-Ham; Chung, Mandy Man-Ling; Fong, Daniel Tik-Pui; Law, Billy Kan-Yip; Yung, Patrick Shu-Hang; Chan, Wood-Yee; Chan, Kai-Ming

    2011-01-01

    This study aimed to evaluate the immediate effect on knee kinematics by 2 different techniques of posterolateral corner (PLC) reconstruction. Five intact formalin-preserved cadaveric knees were used in this study. A navigation system was used to measure knee kinematics (posterior translation, varus angulation, and external rotation) after application of a constant force and torque to the tibia. Four different conditions of the knee were evaluated during the biomechanical test: intact knee and PLC-sectioned knee and PLC-reconstructed knee by the double-femoral tunnel technique and single-femoral tunnel technique. Sectioning of the PLC structures resulted in significant increases in external rotation at 30° of flexion from 11.2° (SD, 2.6) to 24.6° (SD, 6.2), posterior translation at 30° of flexion from 3.4 mm (SD, 1.5) to 7.4 mm (SD, 3.8), and varus angulation at 0° of flexion from 2.3° (SD, 2.1) to 7.9° (SD, 5.1). Both reconstruction techniques significantly restored the varus stability. The external rotation and posterior translation at 30° of flexion after reconstruction with the double-femoral tunnel technique were 10.2° (SD, 1.3) and 3.4° (SD, 2.7), respectively, which were significantly better than those of the single-femoral tunnel technique. Both techniques of reconstruction showed improved stability compared with PLC-sectioned knees. The double-femoral tunnel technique in PLC reconstruction showed better rotational stability and resistance to posterior translation than the single-femoral tunnel technique without compromising varus stability. PLC reconstruction by a double-femoral tunnel technique achieves better rotational control and resistance to posterior translation. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  5. [Midterm follow-up results on Asian femoral intramedullary nail for the treatment of segmental and comminuted femoral fractures].

    Science.gov (United States)

    Li, Lang; Gao, Feng; Huang, Qi; Li, Qiang; Xie, Lin; Zhang, Bin

    2016-06-01

    To investigate midterm follow-up results on Asian femoral intramedullary nail in treating segmental and comminuted femoral fractures. Between June 2011 and October 2012,16 patients with segmental and comminuted femoral fractures were treated with minimally invasive reset and Asian femoral intramedullary nail under extension table. Among them, there were 10 males and 6 females aged from 21 to 49 years old with an average of 34.5 years old; the time from injury to operation ranged from 3 to 24 d with an average of 9.1 d. There were 6 cases were type C1,2 cases were type C2 and 8 cases were type C3 according to AO classification. X-ray of femoral segment at 3,6 and 12 months after operation were applied for evaluating fracture healing. Harris score of hip joint and HSS score of knee joint were used to evaluate postoperative function. All patients were followed up from 24 to 36 months with an average of 28.4 months. Operative time was from 88 to 112 min with an average of 90.7 min; blood loss ranged from 150 to 200 ml with an average of 188.75 ml; the time of fracture healing was from 5 to 9 months with an average of 5.4 months. All incision were healed at stage I. No loosening, breakage of internal fixation and displacement of fracture were occurred. There were no significant differences in Harris score of hip joint at 3, 6 and 12 months after operation (F = 0.07, P = 0.893 > 0.05), 10 cases obtained excellent results, 5 good and 1 moderate. There was no obvious meaning in HSS score of knee joint (F = 0.08,P = 0.876 > 0.05), 9 cases obtained excellent results, 6 good and 1 poor. Asian femoral intramedullary nail could treat segmental and comminuted femoral fractures by using variety of less invasive ways,which has advantages of less trauma, quick recovery of function and satisfied midterm following-up results. But long term following-up effects remains to be seen.

  6. Suppression of tunneling leakage current in junctionless nanowire transistors

    International Nuclear Information System (INIS)

    Lou, Haijun; Li, Dan; Dong, Yan; Lin, Xinnan; He, Jin; Yang, Shengqi; Chan, Mansun

    2013-01-01

    In this paper, the characteristics of tunneling leakage current for the dual-material gate junctionless nanowire transistor (DMG-JNT) are investigated by three-dimensional numerical simulations and compared with conventional junctionless nanowire transistor (JNT). The suppression of the tunneling leakage current on the JNT by introducing an energy band step with the DMG structure is verified and presented for the first time. The effects of channel length on the DMG-JNT and the JNT are also studied. Results showed that the tunneling leakage current of the DMG-JNT is two orders smaller than that of the JNT, and further, the DMG-JNT exhibits superior scaling capability. Two key design parameters of the DMG-JNT, control gate ratio (Ra) and work function difference (δW), have been optimized and the optimal ranges of Ra and δW are pointed out. (paper)

  7. Suppression of tunneling leakage current in junctionless nanowire transistors

    Science.gov (United States)

    Lou, Haijun; Li, Dan; Dong, Yan; Lin, Xinnan; He, Jin; Yang, Shengqi; Chan, Mansun

    2013-12-01

    In this paper, the characteristics of tunneling leakage current for the dual-material gate junctionless nanowire transistor (DMG-JNT) are investigated by three-dimensional numerical simulations and compared with conventional junctionless nanowire transistor (JNT). The suppression of the tunneling leakage current on the JNT by introducing an energy band step with the DMG structure is verified and presented for the first time. The effects of channel length on the DMG-JNT and the JNT are also studied. Results showed that the tunneling leakage current of the DMG-JNT is two orders smaller than that of the JNT, and further, the DMG-JNT exhibits superior scaling capability. Two key design parameters of the DMG-JNT, control gate ratio (Ra) and work function difference (δW), have been optimized and the optimal ranges of Ra and δW are pointed out.

  8. THE ROLE OF ASTRO-GEODETIC IN PRECISE GUIDANCE OF LONG TUNNELS

    Directory of Open Access Journals (Sweden)

    M. Mirghasempour

    2015-12-01

    Full Text Available One of prime aspects of surveying projects is guidance of paths of a long tunnel from different directions and finally ending all paths in a specific place. This kind of underground surveying, because of particular condition, has some different points in relation to the ground surveying, including Improper geometry in underground transverse, low precise measurement in direction and length due to condition such as refraction, distinct gravity between underground point and corresponding point on the ground (both value and direction of gravity and etc. To solve this problems, astro-geodetic that is part of geodesy science, can help surveying engineers. In this article, the role of astronomy is defined in two subjects: 1- Azimuth determination of directions from entrance and exit nets of tunnel and also calibration of gyro-theodolite to use them in Underground transvers: By astronomical methods, azimuth of directions can be determine with an accuracy of 0.5 arcsecond, whereas, nowadays, no gyroscope can measure the azimuth in this accuracy; For instance, accuracy of the most precise gyroscope (Gyromat 5000 is 1.2 cm over a distance of one kilometre (2.4 arcsecond. Furthermore, the calibration methods that will be mention in this article, have significance effects on underground transverse. 2- Height relation between entrance point and exit point is problematic and time consuming; For example, in a 3 km long tunnel ( in Arak- Khoram Abad freeway, to relate entrance point to exit point, it is necessary to perform levelling about 90 km. Other example of this boring and time consuming levelling is in Kerman tunnel. This tunnel is 36 km length, but to transfer the entrance point height to exit point, 150 km levelling is needed. According to this paper, The solution for this difficulty is application of astro-geodetic and determination of vertical deflection by digital zenith camera system TZK2-D. These two elements make possible to define geoid profile

  9. Is Botulinum Toxin Type A a Valuable Adjunct During Femoral Lengthening? A Randomized Trial.

    Science.gov (United States)

    Park, Hoon; Shin, Soowan; Shin, Han Sol; Kim, Hyun Woo; Kim, Dong Wook; Lee, Dong Hoon

    2016-12-01

    Reduced joint ROM and distraction-induced pain are common complaints of patients who have undergone gradual femoral lengthening. Attempts to reduce the effects of lengthening on joint motion have included the use of botulinum toxin to reduce the muscle forces that restrict motion. The benefits of this approach during femoral lengthening, however, have not been conclusively established. We wished to evaluate the effects of botulinum toxin type A (BtX-A) injection in the anterior thigh muscles during femoral distraction osteogenesis on adjacent joint ROM and distraction-induced pain. We asked: (1) Does injection of BtX-A in the quadriceps muscles lead to improved knee and hip motion during femoral lengthening? (2) Does injection of BtX-A reduce pain during femoral lengthening? A single-center, double-blind, randomized placebo-controlled trial was conducted. Forty-four patients (88 femurs) undergoing bilateral femoral lengthening for familial short stature were included in the study. BtX-A (200 IU) was injected intraoperatively in the quadriceps muscles of one thigh. An equal volume of sterile normal saline was injected in the other thigh as a control. Selection of the limb receiving the toxin was randomized. Clinical evaluation included a VAS score for pain measurement, ROM evaluation of the hips and knees, and measurement of thigh circumference. Side-to-side differences were analyzed throughout the entire consolidation phase. No patients were lost to followup, leaving 44 patients (88 femurs). The mean followup was 26 months (range, 14-40 months). The distraction rate and final length of gain were similar between treated and control limbs. A priori power analysis suggested that 44 legs were required in each group to achieve statistical significance of 0.05 with 90% power to detect a 50% difference in treatment effect between treatment and control groups. There were no differences in hip ROM, knee ROM, or maximal thigh circumference between the two lower extremities

  10. Computerized tomography in evaluation of decreased acetabular and femoral anteversion

    International Nuclear Information System (INIS)

    Toennis, D.; Skamel, H.J.

    2003-01-01

    Computerized tomography has received a new importance. It has been shown that decreased anteversion of femur and acetabulum, when both have decreased angles, are causing pain and osteoarthritis of the hip joint. Operative treatment should be performed before osteoarthritis develops. Exact measurements therefore are necessary. The investigation should be performed in prone position to have the pelvis lying in a defined and normal position. Femoral torsion is measured between the transverse axis of the knee and the femoral neck. The transverse axis for measurement of the femoral anteversion is defined by a rectangular line to the sagittal plane. For evaluation of the femoral anteversion in total the angle of the condyles has to be added to the femoral neck angle when the knee is found in internal rotation. Acetabular anteversion should be measured at the level where the femoral head is still in full contact and congruence with the anterior margin of the acetabulum. (orig.) [de

  11. Femoral neck fracture following groin irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Grigsby, Perry W; Roberts, Heidi L; Perez, Carlos A

    1995-04-30

    Purpose: The incidence and risk factors are evaluated for femoral neck fracture following groin irradiation for gynecologic malignancies. Methods and Materials: The radiation therapy records of 1313 patients with advanced and recurrent cancer of the vagina, vulva, cervix, and endometrium, treated at the Mallinckrodt Institute of Radiology from 1954 to 1992, were reviewed. Median follow-up was 12.7 years. From this group, 207 patients were identified who received irradiation to the pelvis and groins with anterposterior-posterior anterior (AP-PA), 18 MV photons. Data were reviewed regarding irradiation dose to the femoral neck and other presumed risk factors including age, primary site, stage, groin node status, menopausal status, estrogen use, cigarette use, alcohol consumption, and osteoporosis. Results: The per-patient incidence of femoral neck fracture was 4.8% (10 out of 207). Four patients developed bilateral fractures. However, the cumulative actuarial incidence of fracture was 11% at 5 years and 15% at 10 years. Cox multivariate analysis of age, weight, and irradiation dose showed that only irradiation dose may be important to developing fracture. Step-wise logistic regression of presumed prognostic factors revealed that only cigarette use and x-ray evidence of osteoporosis prior to irradiation treatment were predictive of fracture. Conclusion: Femoral head fracture is a common complication of groin irradiation for gynecologic malignancies. Fracture in our database appears to be related to irradiation dose, cigarette use, and x-ray evidence of osteoporosis. Special attention should be given in treatment planning (i.e., shielding of femoral head/neck and use of appropriate electron beam energies for a portion of treatment) to reduce the incidence of this complication.

  12. Femoral neck fracture following groin irradiation

    International Nuclear Information System (INIS)

    Grigsby, Perry W.; Roberts, Heidi L.; Perez, Carlos A.

    1995-01-01

    Purpose: The incidence and risk factors are evaluated for femoral neck fracture following groin irradiation for gynecologic malignancies. Methods and Materials: The radiation therapy records of 1313 patients with advanced and recurrent cancer of the vagina, vulva, cervix, and endometrium, treated at the Mallinckrodt Institute of Radiology from 1954 to 1992, were reviewed. Median follow-up was 12.7 years. From this group, 207 patients were identified who received irradiation to the pelvis and groins with anterposterior-posterior anterior (AP-PA), 18 MV photons. Data were reviewed regarding irradiation dose to the femoral neck and other presumed risk factors including age, primary site, stage, groin node status, menopausal status, estrogen use, cigarette use, alcohol consumption, and osteoporosis. Results: The per-patient incidence of femoral neck fracture was 4.8% (10 out of 207). Four patients developed bilateral fractures. However, the cumulative actuarial incidence of fracture was 11% at 5 years and 15% at 10 years. Cox multivariate analysis of age, weight, and irradiation dose showed that only irradiation dose may be important to developing fracture. Step-wise logistic regression of presumed prognostic factors revealed that only cigarette use and x-ray evidence of osteoporosis prior to irradiation treatment were predictive of fracture. Conclusion: Femoral head fracture is a common complication of groin irradiation for gynecologic malignancies. Fracture in our database appears to be related to irradiation dose, cigarette use, and x-ray evidence of osteoporosis. Special attention should be given in treatment planning (i.e., shielding of femoral head/neck and use of appropriate electron beam energies for a portion of treatment) to reduce the incidence of this complication

  13. Estimated carotid-femoral pulse wave velocity has similar predictive value as measured carotid-femoral pulse wave velocity

    DEFF Research Database (Denmark)

    Greve, Sara V; Blicher, Marie K; Kruger, Ruan

    2016-01-01

    BACKGROUND: Carotid-femoral pulse wave velocity (cfPWV) adds significantly to traditional cardiovascular risk prediction, but is not widely available. Therefore, it would be helpful if cfPWV could be replaced by an estimated carotid-femoral pulse wave velocity (ePWV) using age and mean blood pres...... that these traditional risk scores have underestimated the complicated impact of age and blood pressure on arterial stiffness and cardiovascular risk....

  14. A cementless, proximally fixed anatomic femoral stem induces high micromotion with nontraumatic femoral avascular necrosis: A finite element study

    Directory of Open Access Journals (Sweden)

    Wen-Chuan Chen

    2014-07-01

    Full Text Available Decrease in bone mineral density of metaphysis in patients with nontraumatic avascular necrosis of the femoral head (AVN is considered the main factor leading to aseptic loosening of the femoral component. Researchers have hypothesized that a cementless, anatomic stem fixed proximally to the metaphysis has a higher risk for aseptic loosening than a straight stem that is fixed at the diaphysis in patients with nontraumatic AVN. The purpose of the current study was to evaluate the effects of cancellous bone stiffness at the metaphysis and stem geometry on the micromotion of the femoral stem relative to the femur. The VerSys (straight and ABG (anatomic femoral stems were enrolled in this finite element study to determine the performance of prosthetic micromotion. The simulated load to the hip joint during heel strike was assigned. Results showed that the VerSys model represented better resistance in micromotion between the bone/stem interface than the ABG model in either normal or poor cancellous bone stiffness at the metaphysis. The bone quality at the metaphysis of patients with nontraumatic AVN should be considered prior to selecting a femoral stem. In consideration of initial stability, acementless, straight stem that fits the isthmus is more favourable than an anatomic stem that is fixed to the proximal area of the canal.

  15. Air Quality and Microclimatic Parameters During Excavation of Mala Kapela Tunnel

    Directory of Open Access Journals (Sweden)

    Mario Klanfar

    2015-06-01

    Full Text Available During excavation of the Mala Kapela tunnel, measurements of harmful gases concentration, ventilation parameters and microclimatic parameters were performed. Measurements were done in 17 occasions during period of 16 months, along the advance of the tunnel excavation. Consequently, large amount of data was obtained, in different tunnel chainages, ventilation ducts length, and in different work operations during the excavation. Main sources of harmful gases during tunnel excavation are explosives and diesel equipment. The concentration of the same mainly depends on explosive charge and overall diesel equipment power, present at the excavation face of the tunnel. Continuous measurements of the concentration of carbon monoxide (CO and dioxide (CO2, and nitrogen oxide (NO and dioxide (NO2 was performed during drilling, blasting, and loading and haulage operations. Measurements were done in 45 cases in total. Recorded data was analysed, where peak concentrations were joined to corresponding operation and the tunnel chainage. Regulations on threshold limit values were used to determine if concentrations rise above the permissible ones. In case they do, the time required for dilution of gases below permissible concentration was noted. Typically, concentrations of all measured gases rise rapidly after blasting. Afterwards, ventilation system acts to dilute them and maintain them relatively constant until the end of loading and haulage. According to measurements in this research, highest concentrations and longest time of dilution were found after blasting. At the same time, concentration of all measured gases exceeds permissible values. Carbon monoxide is found to exceed permissible values during all work operations. It shows most frequent transgression above the limit (in 33 to 100% of cases and highest time of dilution (up to 40 min. Air supply to the excavation face was measured in 25 cases. It was correlated to the length of ventilation ducts, as

  16. Femoral neck fractures complicating gaucher disease in children

    International Nuclear Information System (INIS)

    Goldman, A.B.; Jacobs, B.

    1984-01-01

    In normal children, fractures of the femoral neck are uncommon and accompany severe trauma and multiple injuries elsewhere in the skeleton. In children with Gaucher disease, a rare hereditary disorder of lipid metabolism, midcervical or basicervical fractures can occur with minor or no trauma and without other injury to the skeleton. Three children with Gaucher disease who developed pathologic fractures of the femoral neck are described. In all three, the fractures occurred between five and nine years of age, and the fracture lines passed through areas of abnormal bone characterized by poorly defined patches of increased and decreased density and cortical thinning along the medial femoral necks. In the affected hips, there was no evidence of avascular necrosis of the femoral heads at the time of injury. One child's fracture was preceeded by multiple bone 'crisis' localized to the proximal femora. (orig.)

  17. Femoral neck fractures complicating gaucher disease in children

    Energy Technology Data Exchange (ETDEWEB)

    Goldman, A B; Jacobs, B

    1984-09-01

    In normal children, fractures of the femoral neck are uncommon and accompany severe trauma and multiple injuries elsewhere in the skeleton. In children with Gaucher disease, a rare hereditary disorder of lipid metabolism, midcervical or basicervical fractures can occur with minor or no trauma and without other injury to the skeleton. Three children with Gaucher disease who developed pathologic fractures of the femoral neck are described. In all three, the fractures occurred between five and nine years of age, and the fracture lines passed through areas of abnormal bone characterized by poorly defined patches of increased and decreased density and cortical thinning along the medial femoral necks. In the affected hips, there was no evidence of avascular necrosis of the femoral heads at the time of injury. One child's fracture was preceeded by multiple bone 'crisis' localized to the proximal femora.

  18. frequency of ipsilateral femoral neck fractures in patients

    African Journals Online (AJOL)

    Background: Ipsilateral associated femoral neck and shaft fractures are reported to occur in 2.5-6% of all femoral shaft ... nailing of the shaft fracture, which makes treatment of the neck ... chest, spine), while the other had maxillofacial injuries.

  19. Quantum confinement effects and source-to-drain tunneling in ultra-scaled double-gate silicon n-MOSFETs

    International Nuclear Information System (INIS)

    Jiang Xiang-Wei; Li Shu-Shen

    2012-01-01

    By using the linear combination of bulk band (LCBB) method incorporated with the top of the barrier splitting (TBS) model, we present a comprehensive study on the quantum confinement effects and the source-to-drain tunneling in the ultra-scaled double-gate (DG) metal—oxide—semiconductor field-effect transistors (MOSFETs). A critical body thickness value of 5 nm is found, below which severe valley splittings among different X valleys for the occupied charge density and the current contributions occur in ultra-thin silicon body structures. It is also found that the tunneling current could be nearly 100% with an ultra-scaled channel length. Different from the previous simulation results, it is found that the source-to-drain tunneling could be effectively suppressed in the ultra-thin body thickness (2.0 nm and below) by the quantum confinement and the tunneling could be suppressed down to below 5% when the channel length approaches 16 nm regardless of the body thickness. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  20. Sequential MRI Study of Graft Integrity and Signal Following Pediatric All-epiphyseal ACL Reconstruction: Does the “Sharp Turn” at the Socket of the Distal Femoral Aperture Matter?

    Science.gov (United States)

    Tuca, Maria; Greditzer, Harry Gus; Gausden, Elizabeth Bishop; Uppstrom, Tyler J.; Potter, Hollis G.; Cordasco, Frank A.; Green, Daniel W.

    2017-01-01

    Objectives: To analyze graft structure and signal with particular emphasis on the distal femoral socket aperture following all-epiphyseal ACLR using hamstring autografts with sequential MRI in skeletally immature athletes. Methods: Retrospective cohort study of 23 skeletally immature patients who underwent ACLR by the same surgical team at a tertiary center during 2011-2013. Athletes had at least two follow-up MRIs, the first MRI 6-12 months after surgery and the second MRI >18 months, were included. Exclusion criteria included those athletes with inMRI follow-up (6) or with a failure of their reconstructions (1). All athletes were treated with an arthroscopic all-inside, all-epiphyseal ACLR, using hamstring autograft, secured with adjustable loop cortical buttons on both tibia and femur. MRI images were analyzed independently and blinded by an orthopaedic surgery fellow and a musculoskeletal radiology fellow. Using a GE Functional Analysis Software, the signal intensity (SI) of the graft was measured in 5 different locations: 1) femoral tunnel, 2) intra-articular proximal turn, 3) midsubstance, 4) intra-articular distal turn, and 5) tibial tunnel. Values were normalized to cortical bone density. The amount of perigraft scarring and synovitis was analyzed. An intraclass correlation coefficient was used to quantify inter-rater reliability, non-parametric Wilcoxon test for perigraft scarring and synovitis, one-way ANOVA to test if significant differences of SI were seen between the different graft locations, and a 2-tailed student t-test for SI changes from 1st to 2nd MRI. Results: The study included 16 patients (5 girls and 11 boys), with an average age at surgery of 11.9 years (range 10-15). The first follow-up MRI was on average at 8.4 months (range 6-12 months), while the 2nd MRI was on average 30.7 months (range 18-40) after surgery. Intra-class correlation coefficients were above 0.7 for all measurements, indicating an excellent concordance between observers

  1. Proximal femoral fractures

    DEFF Research Database (Denmark)

    Palm, Henrik; Teixidor, Jordi

    2015-01-01

    searched the homepages of the national heath authorities and national orthopedic societies in West Europe and found 11 national or regional (in case of no national) guidelines including any type of proximal femoral fracture surgery. RESULTS: Pathway consensus is outspread (internal fixation for un...

  2. STM tunneling through a quantum wire with a side-attached impurity

    International Nuclear Information System (INIS)

    Kwapinski, T.; Krawiec, M.; Jalochowski, M.

    2008-01-01

    The STM tunneling through a quantum wire (QW) with a side-attached impurity (atom, island) is investigated using a tight-binding model and the non-equilibrium Keldysh Green function method. The impurity can be coupled to one or more QW atoms. The presence of the impurity strongly modifies the local density of states of the wire atoms, thus influences the STM tunneling through all the wire atoms. The transport properties of the impurity itself are also investigated mainly as a function of the wire length and the way it is coupled to the wire. It is shown that the properties of the impurity itself and the way it is coupled to the wire strongly influence the STM tunneling, the density of states and differential conductance

  3. Localized cortical thickening of the femoral diaphysis captured on an X-ray before alendronate therapy in two cases of atypical femoral fracture

    Energy Technology Data Exchange (ETDEWEB)

    Iizuka, Yoichi [Gunma University Graduate School of Medicine, Department of Orthopedic Surgery, Maebashi, Gunma (Japan); Shibukawa General Hospital, Department of Orthopedic Surgery, Shibukawa, Gunma (Japan); Takechi, Rumi [Gunma University Graduate School of Medicine, Department of Orthopedic Surgery, Maebashi, Gunma (Japan); Gunma Cardiovascular Center, Department of Orthopaedic Surgery, Maebashi, Gunma (Japan); Iizuka, Haku; Takagishi, Kenji [Gunma University Graduate School of Medicine, Department of Orthopedic Surgery, Maebashi, Gunma (Japan); Omodaka, Takuya [Gunma University Graduate School of Medicine, Department of Orthopedic Surgery, Maebashi, Gunma (Japan); Gunma Central Hospital, Department of Orthopedic Surgery, Maebashi, Gunma (Japan)

    2016-10-15

    We herein report two cases of atypical femoral fracture (AFF). X-ray examinations at the first visit of these two female patients showed a complete fracture of the femoral diaphysis diagnosed as an atypical femoral fracture (AFF). X-rays of these two cases also showed localized cortical thickening of the femoral diaphysis. Both patients had been taking alendronate for more than 3 years because of postmenopausal osteoporosis. We assumed that both of the fractures were associated with the long-term use of alendronate. However, we retrospectively identified localized cortical thickening of the femoral diaphysis on an X-ray taken before the alendronate therapy in both of these cases. Therefore, we suspected a pathogenesis of AFFs in which preexisting stress or an insufficient fracture unrelated to bisphosphonate (BP) therapy and subsequent suppression of bone turnover due to BP administration led to the occurrence of an AFF. The patient underwent surgery using intramedullary nails in both of these cases, followed by the administration of teriparatide, and they were able to walk without any support at the final follow-up examination. (orig.)

  4. Iodixanol in femoral arteriography

    International Nuclear Information System (INIS)

    Thorstensen, Oe.; Albrechtsson, U.; Calissendorff, B.; Larusdottir, H.; Norgren, L.; Tengvar, M.; Bolstad, B.; Aspelin, P.

    1994-01-01

    Two contrast media, iodixanol (Visipaque, Nycomed) 270 mg I/ml and iohexol (Omnipaque, Nycomed) 300 mg I/ml, were compared in femoral arteriography, in 147 patients. Both contrast media were diagnostically effective for use in femoral arteriography, without any significant difference. Pain was reported in connection with injection of iohexol by 36% of the patients, after injection of iodixanol none reported pain. Seventy-two percent of the patients in the iodixanol group reported a sensation of warmth in connection with contrast injection versus 90% in the iohexol group. The average intensity of the warmth was greater with iohexol than with iodixanol. Fourteen percent of patients in the iodixanol group and 1% in the iohexol group reported one or more subjective adverse events. (orig.)

  5. Femoral Neck Shaft Angle in Men with Fragility Fractures

    Directory of Open Access Journals (Sweden)

    S. P. Tuck

    2011-01-01

    Full Text Available Introduction. Femoral neck shaft angle (NSA has been reported to be an independent predictor of hip fracture risk in men. We aimed to assess the role of NSA in UK men. Methods. The NSA was measured manually from the DXA scan printout in men with hip (62, 31 femoral neck and 31 trochanteric, symptomatic vertebral (91, and distal forearm (67 fractures and 389 age-matched control subjects. Age, height, weight, and BMD (g/cm2: lumbar spine, femoral neck, and total femur measurements were performed. Results. There was no significant difference in mean NSA between men with femoral neck and trochanteric hip fractures, so all further analyses of hip fractures utilised the combined data. There was no difference in NSA between those with hip fractures and those without (either using the combined data or analysing trochanteric and femoral neck shaft fractures separately, nor between fracture subjects as a whole and controls. Mean NSA was smaller in those with vertebral fractures (129.2° versus 131°: P=0.001, but larger in those with distal forearm fractures (129.8° versus 128.5°: P=0.01. Conclusions. The conflicting results suggest that femoral NSA is not an important determinant of hip fracture risk in UK men.

  6. Logistic regression analysis of factors associated with avascular necrosis of the femoral head following femoral neck fractures in middle-aged and elderly patients.

    Science.gov (United States)

    Ai, Zi-Sheng; Gao, You-Shui; Sun, Yuan; Liu, Yue; Zhang, Chang-Qing; Jiang, Cheng-Hua

    2013-03-01

    Risk factors for femoral neck fracture-induced avascular necrosis of the femoral head have not been elucidated clearly in middle-aged and elderly patients. Moreover, the high incidence of screw removal in China and its effect on the fate of the involved femoral head require statistical methods to reflect their intrinsic relationship. Ninety-nine patients older than 45 years with femoral neck fracture were treated by internal fixation between May 1999 and April 2004. Descriptive analysis, interaction analysis between associated factors, single factor logistic regression, multivariate logistic regression, and detailed interaction analysis were employed to explore potential relationships among associated factors. Avascular necrosis of the femoral head was found in 15 cases (15.2 %). Age × the status of implants (removal vs. maintenance) and gender × the timing of reduction were interactive according to two-factor interactive analysis. Age, the displacement of fractures, the quality of reduction, and the status of implants were found to be significant factors in single factor logistic regression analysis. Age, age × the status of implants, and the quality of reduction were found to be significant factors in multivariate logistic regression analysis. In fine interaction analysis after multivariate logistic regression analysis, implant removal was the most important risk factor for avascular necrosis in 56-to-85-year-old patients, with a risk ratio of 26.00 (95 % CI = 3.076-219.747). The middle-aged and elderly have less incidence of avascular necrosis of the femoral head following femoral neck fractures treated by cannulated screws. The removal of cannulated screws can induce a significantly high incidence of avascular necrosis of the femoral head in elderly patients, while a high-quality reduction is helpful to reduce avascular necrosis.

  7. Combined Radial and Femoral Access Strategy and Radial-Femoral Rendezvous in Patients With Long and Complex Iliac Occlusions.

    Science.gov (United States)

    Hanna, Elias B; Mogabgab, Owen N; Baydoun, Hassan

    2018-01-01

    We present cases of complex, calcified iliac occlusive disease revascularized via a combined radial-femoral access strategy. Through a 6-French, 125-cm transradial guiding catheter, antegrade guidewires and catheters are advanced into the iliac occlusion, while retrograde devices are advanced transfemorally. The transradial and transfemoral channels communicate, allowing the devices to cross the occlusion into the true lumen (radial-femoral antegrade-retrograde rendezvous).

  8. 'Femoral head necrosis' in metabolic and hormonal osteopathies

    International Nuclear Information System (INIS)

    Heuck, F.H.W.; Treugut, H.

    1984-01-01

    The pathogenesis of bone necrosis is discussed with special attention and with respect to metabolic, hormonal, and vascular factors. The influence of statics and dynamics of the hip joint bones for the development of aseptic necrosis are discussed. 45 patients with ''idiopathic femoral head necroses'' were observed, including 6 cases of renal osteopathy following renal transplantation and immune suppression therapy, 14 cases of long term corticoid therapy, and 11 cases of liver diseases of different genesis. The femoral head necrosis understood as complication of an osteopathy. In our patients there were 31 males and 14 females - which means higher involvement of males. Plain radiological findings and CT-findings of changes of the femoral heat structure in different stages of the disease are described. Early diagnosis of metabolic and hormonal osteopathies is demanded for a joint keeping therapy of the beginning femoral head necrosis. (orig.) [de

  9. Femoral neck fractures complicating gaucher disease in children

    Energy Technology Data Exchange (ETDEWEB)

    Goldman, A.B.; Jacobs, B.

    1984-09-01

    In normal children, fractures of the femoral neck are uncommon and accompany severe trauma and multiple injuries elsewhere in the skeleton. In children with Gaucher disease, a rare hereditary disorder of lipid metabolism, midcervical or basicervical fractures can occur with minor or no trauma and without other injury to the skeleton. Three children with Gaucher disease who developed pathologic fractures of the femoral neck are described. In all three, the fractures occurred between five and nine years of age, and the fracture lines passed through areas of abnormal bone characterized by poorly defined patches of increased and decreased density and cortical thinning along the medial femoral necks. In the affected hips, there was no evidence of avascular necrosis of the femoral heads at the time of injury. One child's fracture was preceeded by multiple bone 'crisis' localized to the proximal femora.

  10. MRI for early diagnosis of avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Kokubo, Takashi; Takatori, Yoshio; Kamogawa, Morihide; Ninomiya, Setsuo; Yoshikawa, Kohki; Itai, Yuji; Iio, Masahiro; Mitamura, Tadayuki

    1988-01-01

    Magnetic resonance imaging (MRI) was performed in forty patients on long-term oral steroid therapy for early detection of avascular necrosis (AN) of the femoral head. In 13 patients, AN was diagnosed in the unilateral femoral head from abnormal plain radiographs while the contralateral femoral head was normal radiographically. In the other 27 patients, radiographs were normal. A total of 67 femoral heads with normal radiographs is studied in this paper. In 36 of 67 femoral heads (54 %), MRI demonstrated abnormal low intensity area. The abnormal findings on MRI were divided into five patterns: whole type (type A), peripheral type (type B), ring or band type (type C), small change type (type D) and distal type (type E). Type A, B, C, D and E were found in 2, 11, 5, 16 and 2 femoral heads, respectively. In cases to be followed up over 6 months, AN was manifested radiographically in 4 femoral heads of 5 in type C and in one of 14 in type D. Meanwhile, in 6 of 41 femoral heads examined (15 %), bone scintigrams was abnormal. Followed-up study over 6 months revealed that AN was manifested radiographically in one femoral head of 6 with abnormal scintigram. However, in 4 of 30 with normal scintigram, AN was manifested subsequently. MRI was a better diagnostic modality for early AN. Ring or band-like low intensity (type C) on MRI was considered to be characteristic pattern of early AN. (author)

  11. MRI for early diagnosis of avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Kokubo, Takashi; Takatori, Yoshio; Kamogawa, Morihide; Ninomiya, Setsuo; Yoshikawa, Kohki; Itai, Yuji; Iio, Masahiro; Mitamura, Tadayuki

    1988-09-01

    Magnetic resonance imaging (MRI) was performed in forty patients on long-term oral steroid therapy for early detection of avascular necrosis (AN) of the femoral head. In 13 patients, AN was diagnosed in the unilateral femoral head from abnormal plain radiographs while the contralateral femoral head was normal radiographically. In the other 27 patients, radiographs were normal. A total of 67 femoral heads with normal radiographs is studied in this paper. In 36 of 67 femoral heads (54 %), MRI demonstrated abnormal low intensity area. The abnormal findings on MRI were divided into five patterns: whole type (type A), peripheral type (type B), ring or band type (type C), small change type (type D) and distal type (type E). Type A, B, C, D and E were found in 2, 11, 5, 16 and 2 femoral heads, respectively. In cases to be followed up over 6 months, AN was manifested radiographically in 4 femoral heads of 5 in type C and in one of 14 in type D. Meanwhile, in 6 of 41 femoral heads examined (15 %), bone scintigrams was abnormal. Followed-up study over 6 months revealed that AN was manifested radiographically in one femoral head of 6 with abnormal scintigram. However, in 4 of 30 with normal scintigram, AN was manifested subsequently. MRI was a better diagnostic modality for early AN. Ring or band-like low intensity (type C) on MRI was considered to be characteristic pattern of early AN.

  12. Is Contralateral Templating Reliable for Establishing Rotational Alignment During Intramedullary Stabilization of Femoral Shaft Fractures? A Study of Individual Bilateral Differences in Femoral Version.

    Science.gov (United States)

    Croom, William P; Lorenzana, Daniel J; Auran, Richard L; Cavallero, Matthew J; Heckmann, Nathanael; Lee, Jackson; White, Eric A

    2018-02-01

    To determine native individual bilateral differences (IBDs) in femoral version in a diverse population. Computed tomography scans with complete imaging of uninjured bilateral femora were used to determine femoral version and IBDs in version. Age, sex, and ethnicity of each subject were also collected. Femoral version and IBDs in version were correlated with demographic variables using univariate and multivariate regression models. One hundred sixty-four subjects were included in the study. The average femoral version was 9.4 degrees (±9.4 degrees). The mean IBD in femoral version was 5.4 degrees (±4.4 degrees, P alignment during intramedullary stabilization of diaphyseal femur fractures. This is also an important consideration when considering malrotation of femur fractures because most studies define malrotation as a greater than 10-15-degree difference compared with the contralateral side. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  13. Proximal Focal Femoral Deficiency in Ibadan a Developing ...

    African Journals Online (AJOL)

    The cultural aversion to amputation in our environment makes it difficult to employ that option of treatment. Proximal focal femoral deficiency in Ibadan a developing country's perspective and a review of the literature. Keywords: Proximal focal femoral deficiency , congenital malformations , limb malformations , lower limb ...

  14. Femoral neck radiography: effect of flexion on visualization

    International Nuclear Information System (INIS)

    Garry, S.C.; Jhangri, G.S.; Lambert, R.G.W.

    2005-01-01

    To determine whether flexion improves radiographic visualization of the femoral neck when the femur is externally rotated. Five human femora, with varying neck-shaft and anteversion angles, were measured and immobilized. Degree of flexion required to bring the femoral neck horizontal was measured, varying the rotation. Next, one bone was radiographed in 16 positions, varying rotation in 15 o and flexion in 10 o increments. Radiographs were presented in randomized blinded fashion to 15 staff radiologists for scoring of femoral neck visualization. Following this, all 5 bones were radiographed in 4 positions of rotation and at 0 o and 20 o flexion, and blinded randomized review of radiographs was repeated. Comparisons between angles and rotations were made using the Mann-Whitney test. The flexion angle required to bring the long axis of the femoral neck horizontal correlated directly with the degree of external rotation (ρ o internal rotation to 30 o external rotation (ρ o flexion was applied to bones in external rotation, visualization significantly improved at 15 o (ρ o (ρ o ) of flexion can significantly improve radiographic visualization. This manoeuvre could be useful for radiography of the femoral neck when initial radiographs are inadequate because of external rotation of the leg. (author)

  15. Analytical model for vibration prediction of two parallel tunnels in a full-space

    Science.gov (United States)

    He, Chao; Zhou, Shunhua; Guo, Peijun; Di, Honggui; Zhang, Xiaohui

    2018-06-01

    This paper presents a three-dimensional analytical model for the prediction of ground vibrations from two parallel tunnels embedded in a full-space. The two tunnels are modelled as cylindrical shells of infinite length, and the surrounding soil is modelled as a full-space with two cylindrical cavities. A virtual interface is introduced to divide the soil into the right layer and the left layer. By transforming the cylindrical waves into the plane waves, the solution of wave propagation in the full-space with two cylindrical cavities is obtained. The transformations from the plane waves to cylindrical waves are then used to satisfy the boundary conditions on the tunnel-soil interfaces. The proposed model provides a highly efficient tool to predict the ground vibration induced by the underground railway, which accounts for the dynamic interaction between neighbouring tunnels. Analysis of the vibration fields produced over a range of frequencies and soil properties is conducted. When the distance between the two tunnels is smaller than three times the tunnel diameter, the interaction between neighbouring tunnels is highly significant, at times in the order of 20 dB. It is necessary to consider the interaction between neighbouring tunnels for the prediction of ground vibrations induced underground railways.

  16. Design and analysis of the tunnel connecting the beam corridor and the spectrum hall of the CSNS

    International Nuclear Information System (INIS)

    Liu Jian; Wang Qingbin; Wu Qingbiao; Ma Zhongjian

    2011-01-01

    There is a tunnel connecting the beamcorridor and the target station in the spectrum hall in the CSNS project. The length of the tunnel is about 20 m. The shielding design of the tunnel is very significant for the persons working in the spectrum hall because the tunnel is not covered by soil for shielding. In order to reduce the dose rate at the exit of the cable ducts, we use the ISIS construction, which is designed with four turnings, as a reference for the tunnel design. The thickness of the shielding is obtained by a simulation with the Monte Carlo Code FLUKA. The result is compared with the data obtained with Moyer Mode and the reliability of the simulation is proved. This paper provides the basis for the design of the tunnel. (authors)

  17. T1rho mapping of entire femoral cartilage using depth- and angle-dependent analysis

    International Nuclear Information System (INIS)

    Nozaki, Taiki; Kaneko, Yasuhito; Yu, Hon J.; Yoshioka, Hiroshi; Kaneshiro, Kayleigh; Schwarzkopf, Ran; Hara, Takeshi

    2016-01-01

    To create and evaluate normalized T1rho profiles of the entire femoral cartilage in healthy subjects with three-dimensional (3D) angle- and depth-dependent analysis. T1rho images of the knee from 20 healthy volunteers were acquired on a 3.0-T unit. Cartilage segmentation of the entire femur was performed slice-by-slice by a board-certified radiologist. The T1rho depth/angle-dependent profile was investigated by partitioning cartilage into superficial and deep layers, and angular segmentation in increments of 4 over the length of segmented cartilage. Average T1rho values were calculated with normalized T1rho profiles. Surface maps and 3D graphs were created. T1rho profiles have regional and depth variations, with no significant magic angle effect. Average T1rho values in the superficial layer of the femoral cartilage were higher than those in the deep layer in most locations (p < 0.05). T1rho values in the deep layer of the weight-bearing portions of the medial and lateral condyles were lower than those of the corresponding non-weight-bearing portions (p < 0.05). Surface maps and 3D graphs demonstrated that cartilage T1rho values were not homogeneous over the entire femur. Normalized T1rho profiles from the entire femoral cartilage will be useful for diagnosing local or early T1rho abnormalities and osteoarthritis in clinical applications. (orig.)

  18. T1rho mapping of entire femoral cartilage using depth- and angle-dependent analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nozaki, Taiki; Kaneko, Yasuhito; Yu, Hon J.; Yoshioka, Hiroshi [University of California Irvine, Department of Radiological Sciences, Orange, CA (United States); Kaneshiro, Kayleigh [University of California Irvine, School of Medicine, Irvine, CA (United States); Schwarzkopf, Ran [University of California Irvine, Department of Orthopedic Surgery, Irvine, CA (United States); Hara, Takeshi [Gifu University Graduate School of Medicine, Department of Intelligent Image Information, Division of Regeneration and Advanced Medical Sciences, Gifu (Japan)

    2016-06-15

    To create and evaluate normalized T1rho profiles of the entire femoral cartilage in healthy subjects with three-dimensional (3D) angle- and depth-dependent analysis. T1rho images of the knee from 20 healthy volunteers were acquired on a 3.0-T unit. Cartilage segmentation of the entire femur was performed slice-by-slice by a board-certified radiologist. The T1rho depth/angle-dependent profile was investigated by partitioning cartilage into superficial and deep layers, and angular segmentation in increments of 4 over the length of segmented cartilage. Average T1rho values were calculated with normalized T1rho profiles. Surface maps and 3D graphs were created. T1rho profiles have regional and depth variations, with no significant magic angle effect. Average T1rho values in the superficial layer of the femoral cartilage were higher than those in the deep layer in most locations (p < 0.05). T1rho values in the deep layer of the weight-bearing portions of the medial and lateral condyles were lower than those of the corresponding non-weight-bearing portions (p < 0.05). Surface maps and 3D graphs demonstrated that cartilage T1rho values were not homogeneous over the entire femur. Normalized T1rho profiles from the entire femoral cartilage will be useful for diagnosing local or early T1rho abnormalities and osteoarthritis in clinical applications. (orig.)

  19. Quantitative CT assessment of proximal femoral bone density. An experimental study concerning its correlation to breaking load for femoral neck fractures

    International Nuclear Information System (INIS)

    Buitrago-Tellez, C.H.; Schulze, C.; Gufler, H.; Langer, M.; Bonnaire, F.; Hoenninger, A.; Kuner, E.

    1997-01-01

    Purpose: In an experimental study, the correlation between the trabecular bone density of the different regions of the proximal femur and the fracture load in the setting of femoral neck fractures was examined. Methods: The bone mineral density 41 random proximal human femora was estimated by single-energy quanitative CT (SE-QCT). The trabecular bone density was measured at the greatest possible extracortical volume at midcapital, midneck and intertrochanteric level and in the 1 cm 3 volumes of the centres of these regions in a standardised 10 mm thick slice in the middle of the femoral neck axis (in mg/ml Ca-hydroxyl apatite). The proximal femora were then isolated and mounted on a compression/bending device under two-legged stand conditions and loaded up to the point when a femoral neck fracture occurred. Results: Statistical analysis revealed a linear correlation between the trabecular bone density and the fracture load for the greater regions, with the highest value in the maximal area of the head (coefficient factor r=0.76). Conclusion: According to our data, the measurement of the trabecular bone by SE-QCT at the femoral head is a more confident adjunct than the neck or trochanteric area to predict a femoral neck fracture. (orig.) [de

  20. Tunneling time, the Hartman effect, and superluminality: A proposed resolution of an old paradox

    International Nuclear Information System (INIS)

    Winful, Herbert G.

    2006-01-01

    The issue of tunneling time is replete with controversy and paradoxes. The controversy stems from the fact that many tunneling time definitions seem to predict superluminal tunneling velocities. One prediction, termed the Hartman effect, states that the tunneling time becomes independent of barrier length for thick enough barriers, ultimately resulting in unbounded tunneling velocities. Experiments done with 'single photons', classical light waves, and microwaves all show this apparent superluminality. The origin of these paradoxical effects has been a mystery for decades. In this article, we review the history of tunneling times starting with the early work of MacColl, Hartman, and Wigner. We discuss some of the tunneling time definitions, with particular emphasis on the phase time (also known as the group delay or Wigner time) and the dwell time. The key experiments are reviewed. We then discuss our recent work, which suggests that the group delay in tunneling is not a transit time as has been assumed for decades. It is, in reality, a lifetime and hence should not be used to assign a speed of barrier traversal. We show how this new understanding along with the concept of energy storage and release resolves all the outstanding tunneling time paradoxes

  1. Surgical strategies in polytraumatized patients with femoral shaft fractures - comparing a German and an Australian level I trauma centre.

    Science.gov (United States)

    Andruszkow, Hagen; Dowrick, Adam S; Frink, Michael; Zeckey, Christian; Krettek, Christian; Hildebrand, Frank; Edwards, Elton R; Mommsen, Philipp

    2013-08-01

    Femoral shaft fractures are one of the most common injuries in multiple trauma patients. Due to their prognostic relevance, there is an ongoing controversial discussion as to the optimal treatment strategy in terms of Damage Control Orthopaedics (DCO) and Early Total Care (ETC). We aimed to describe the differences in fracture management and clinical outcome of multiple trauma patients with concomitant femoral shaft fractures treated at a German and an Australian level I trauma centre using the same inclusion criteria. Polytraumatized patients (ISS ≥ 16) with a femoral shaft fracture aged ≥ 16 years treated at a German and an Australian trauma centre between 2003 and 2007 were included. According to ETC and DCO management principles, we evaluated demographic parameters as well as posttraumatic complications and clinical outcome. Seventy-three patients were treated at the German and 134 patients at the Australian trauma centre. DCO was performed in case of increased injury severity in both hospitals. Prolonged mechanical ventilation time, and length of ICU and hospital stay were demonstrated in DCO treatment regardless of the trauma centre. No differences concerning posttraumatic complications and survival were found between both centres. Survival of patients after DCO was similar to those managed using ETC despite a greater severity of injury and lower probability of survival. There was no difference in the incidence of ARDS. DCO was, however, associated with a greatly increased length of time on mechanical ventilation and length of stay in the ICU. We found no differences concerning patient demographics or clinical outcomes in terms of incidence of ARDS, MODS, or mortality. As such, we propose that comparability between German and Australian trauma populations is justified. Despite a higher ISS in the DCO group, there were no differences in posttraumatic complications and survival depending on ETC or DCO treatment. Further research is required to confirm

  2. Tunnel - history of

    International Nuclear Information System (INIS)

    1998-11-01

    This book introduces history of tunnel in ancient times, the middle ages and modern times, survey of tunnel and classification of bedrock like environment survey of position, survey of the ground, design of tunnel on basic thing of the design, and design of tunnel of bedrock, analysis of stability of tunnel and application of the data, construction of tunnel like lattice girder and steel fiber reinforced shot crete, and maintenance control and repair of tunnel.

  3. Mechanical properties of femoral trabecular bone in dogs

    Directory of Open Access Journals (Sweden)

    Nolte Ingo

    2005-03-01

    Full Text Available Abstract Background Studying mechanical properties of canine trabecular bone is important for a better understanding of fracture mechanics or bone disorders and is also needed for numerical simulation of canine femora. No detailed data about elastic moduli and degrees of anisotropy of canine femoral trabecular bone has been published so far, hence the purpose of this study was to measure the elastic modulus of trabecular bone in canine femoral heads by ultrasound testing and to assess whether assuming isotropy of the cancellous bone in femoral heads in dogs is a valid simplification. Methods From 8 euthanized dogs, both femora were obtained and cubic specimens were cut from the centre of the femoral head which were oriented along the main pressure and tension trajectories. The specimens were tested using a 100 MHz ultrasound transducer in all three orthogonal directions. The directional elastic moduli of trabecular bone tissue and degrees of anisotropy were calculated. Results The elastic modulus along principal bone trajectories was found to be 11.2 GPa ± 0.4, 10.5 ± 2.1 GPa and 10.5 ± 1.8 GPa, respectively. The mean density of the specimens was 1.40 ± 0.09 g/cm3. The degrees of anisotropy revealed a significant inverse relationship with specimen densities. No significant differences were found between the elastic moduli in x, y and z directions, suggesting an effective isotropy of trabecular bone tissue in canine femoral heads. Discussion This study presents detailed data about elastic moduli of trabecular bone tissue obtained from canine femoral heads. Limitations of the study are the relatively small number of animals investigated and the measurement of whole specimen densities instead of trabecular bone densities which might lead to an underestimation of Young's moduli. Publications on elastic moduli of trabecular bone tissue present results that are similar to our data. Conclusion This study provides data about directional elastic

  4. Factors influencing period from surgery to discharge in patients with femoral trochanteric fractures

    Science.gov (United States)

    Shinoda, Soichiro; Mutsuzaki, Hirotaka; Watanabe, Arata; Morita, Hidetaka; Kamioka, Yumiko

    2017-01-01

    [Purpose] The purpose of this study was to investigate factors influencing the period from surgery to discharge in patients with femoral trochanteric fractures. [Subjects and Methods] Sixty patients with femoral trochanteric fractures were investigated retrospectively. Based on the mean period from surgery to discharge (85.6 ± 26.6 days), the patients were divided into two groups: an under-85-day group (range, 29–78 days) and an over-85-day group (87–128 days). Age, gender, fracture type, presence of lesser trochanteric displacement, discharge destination, and walking ability were investigated. The relationship between these factors and the period from surgery to discharge was analyzed with logistic regression analysis. [Results] Age and lesser trochanteric displacement were significantly higher in the over-85-day group, and walking ability before fracture and at discharge were significantly lower in the over-85-day group. Logistic regression analysis showed that lesser trochanteric displacement and age were predictors of the length from surgery to discharge. Lesser trochanteric displacement were observed in 87.5% of these. Immediate displacement after surgery occurred in 57.8% of lesser trochanteric fractures, while 26.3% displaced 1 to 3 weeks after surgery. [Conclusion] This study revealed that lesser trochanteric displacement, higher age, and lower walking ability before fracture and at discharge were associated with longer hospitalizations in patients with femoral trochanteric fractures. Lesser trochanteric displacement were observed in 87.5% of lesser trochanteric fractures. These displacements occurred within 3 weeks after surgery in 84.1% of cases. PMID:29200639

  5. Radionuclide patterns of femoral head disease

    Energy Technology Data Exchange (ETDEWEB)

    Webber, M M; Wagner, J; Cragin, M D [California Univ., Los Angeles (USA). Dept. of Radiological Sciences

    1977-12-01

    The pattern of uptake of bone marrow specific radio-sup(99m)Tc sulfur colloid and the pattern of uptake of bone mineral specific radio-sup(99m)Tc pryophosphate may be valuable in assessing bone vascularity in diseases suspected of causing impaired blood supply, or indicate the presence of reactive bone formation. The low energy of the technetium label has been shown to be superior to /sup 18/F and /sup 85/Sr, and leads to greater imaging detail on the scans. Femoral head scanning with mineral and/or marrow specific radionuclides offers the clinician a method of evaluating the status of the femoral head and possibly an early diagnosis of avascular necrosis before roentgenographic changes occur. This study, which reports on a 5-year experience using radionuclide scanning to assess femoral head vascularity, begins with baseline or normal studies followed by variations of the normal pattern. Typical scan patterns of hip pathology described above are also presented.

  6. Typical Underwater Tunnels in the Mainland of China and Related Tunneling Technologies

    Directory of Open Access Journals (Sweden)

    Kairong Hong

    2017-12-01

    Full Text Available In the past decades, many underwater tunnels have been constructed in the mainland of China, and great progress has been made in related tunneling technologies. This paper presents the history and state of the art of underwater tunnels in the mainland of China in terms of shield-bored tunnels, drill-and-blast tunnels, and immersed tunnels. Typical underwater tunnels of these types in the mainland of China are described, along with innovative technologies regarding comprehensive geological prediction, grouting-based consolidation, the design and construction of large cross-sectional tunnels with shallow cover in weak strata, cutting tool replacement under limited drainage and reduced pressure conditions, the detection and treatment of boulders, the construction of underwater tunnels in areas with high seismic intensity, and the treatment of serious sedimentation in a foundation channel of immersed tunnels. Some suggestions are made regarding the three potential great strait-crossing tunnels—the Qiongzhou Strait-Crossing Tunnel, Bohai Strait-Crossing Tunnel, and Taiwan Strait-Crossing Tunnel—and issues related to these great strait-crossing tunnels that need further study are proposed. Keywords: Underwater tunnel, Strait-crossing tunnel, Shield-bored tunnel, Immersed tunnel, Drill and blast

  7. Individualised distal femoral cut improves femoral component placement and limb alignment during total knee replacement in knees with moderate and severe varus deformity.

    Science.gov (United States)

    Palanisami, Dhanasekararaja; Iyyampillai, Geethan; Shanmugam, Sivaraj; Natesan, Rajkumar; S, Rajasekaran

    2016-10-01

    Our aim was to determine the variation in valgus correction angle and the influence of individualised distal femoral cut on femoral component placement and limb alignment during total knee replacement (TKR) in knees with varus deformity. The study was done prospectively in two stages. In the first stage, the valgus correction angle (VCA) was calculated in long-limb radiographs of 227 patients and correlated with pre-operative parameters of femoral bowing, neck-shaft angle and hip-knee-ankle angle. In the second part comprising of 240 knees with varus deformity, 140 (group 1) had the distal femoral cut individualised according to the calculated VCA, while the remaining 100 knees (group 1) were operated with a fixed distal femoral cut of 5°. The outcome of surgery was studied by grouping the knees as varus 15°. Of the 227 limbs analysed in stage I, 70 knees (31 %) had a VCA angle outside 5-7°. Coronal bowing (p shaft angle (p alignment when VCA was individualised in the groups of knees with varus 10-15° (p 0.002) and varus >15° (p 0.002). Valgus correction angle is highly variable and is influenced by femoral bowing, neck-shaft angle and pre-operative deformity. Individualisation of VCA is preferable in patients with moderate and severe varus deformity. Level 2.

  8. Biophysical stimulation in osteonecrosis of the femoral head

    Directory of Open Access Journals (Sweden)

    Massari Leo

    2009-01-01

    Full Text Available Osteonecrosis of the femoral head is the endpoint of a disease process that results from insufficient blood flow and bone-tissue necrosis, leading to joint instability, collapse of the femoral head, arthritis of the joint, and total hip replacement. Pain is the most frequent clinical symptom. Both bone tissue and cartilage suffer when osteonecrosis of the femoral head develops. Stimulation with pulsed electromagnetic fields (PEMFs has been shown to be useful for enhancing bone repair and for exerting a chondroprotective effect on articular cartilage. Two Italian studies on the treatment of avascular necrosis of the femoral head with PEMFs were presented in this review. In the first study, 68 patients suffering from avascular necrosis of the femoral head were treated with PEMFs in combination with core decompression and autologous bone grafts. The second one is a retrospective analysis of the results of treatment with PEMFs of 76 hips in 66 patients with osteonecrosis of the femoral head. In both studies clinical information and diagnostic imaging were collected at the beginning of the treatment and at the time of follow up. Statistical analysis was performed using chi-square test. Both authors hypothesize that the short-term effect of PEMF stimulation may be to protect the articular cartilage from the catabolic effect of inflammation and subchondral bone-marrow edema. The long-term effect of PEMF stimulation may be to promote osteogenic activity at the necrotic area and prevent trabecular fracture and subchondral bone collapse. PEMF stimulation represents an important therapeutic opportunity to resolve the Ficat stage-I or II disease or at least to delay the time until joint replacement becomes necessary.

  9. One stage revision single-bundle anterior cruciate ligament reconstruction with impacted morselized bone graft following a failed double-bundle reconstruction

    Directory of Open Access Journals (Sweden)

    Ho Jong Ra

    2017-01-01

    Full Text Available Although double-bundle anterior cruciate ligament (ACL reconstruction has theoretical benefits such as more accurate reproduction of ACL anatomy, it is technically more demanding surgery. This report describes the case of a one stage revision single-bundle ACL reconstruction after primary double-bundle ACL reconstruction. A professional dancer had an ACL previously reconstructed with a double-bundle technique, but the femoral tunnels were malpositioned resulting in residual laxity and rotational instability. The previous femoral tunnel positions were vertical and widened. The previous vertical tunnels were filled with impacted bone graft and a revision single-bundle ACL reconstruction was performed via the new femoral tunnel with a 2 O'clock position between the previous two tunnels. After 10 months of postoperative rehabilitation, the patient returned to professional dancing with sound bony union and without any residual instability.

  10. Osteosynthesis of femoral neck fractures: dynamic hip screw (DHS or mini-invasive Targon FN system?

    Directory of Open Access Journals (Sweden)

    A. K. Dulaev

    2015-01-01

    Full Text Available Objectives: to investigate the long-term outcomes of femoral neck fractures that were surgically fixed using various types of extramedullary implants in patients aged 65 years and younger. Material and methods: We analyzed the clinical results of surgical treatment of femoral neck fractures by extramedullary osteosynthesis in 94 patients aged 38 to 65 years old (71 women and 23 men. The patients were divided into 3 groups according to AO/ASIF fracture classification. We used different techniques of osteosynthesis: with DHS or with Targon FN. In all patients the mental status rate SPMSQ, osteoporosis degree (Singh index, general somatic status (WHO scale were evaluated in the preoperative period. We also evaluated next intraoperative parameters: duration of surgery, blood loss, quality of reduction, long of incision. In a year after surgery we assessed functional results (Harris Hip Score and analysed postoperative complications. Results: It was found the inverse correlation (r = -0,8 of total preoperative parameters (WHO scale, the Singh index and mental status SPMSQ and postoperative functional results on Harris Hip Score. With the reliability of p<0.05 the average rate of blood loss and length of skin incision were less in patients operated with Targon FN. In 12 months unsatisfactory results rate on Harris Hip Score was 12.7% in all study groups, great - 22,3%, good - 52.1%, and satisfactory - 12,9%. Complications rate in patients operated with DHS was 17,02%, and in patients operated with Targon FN - 18.1%. Conclusion: Minimally invasive osteosynthesis of femoral neck fractures (type B1 and B2 on AO/ASIF classification allows to achieve the best results in compare with DHS osteosynthesis. Revealed complications such as screw migration, false joint formation and femoral head avascular necrosis were determined by impaired surgical technique and inadequate reduction.

  11. Direct, coherent and incoherent intermediate state tunneling and scanning tunnel microscopy (STM)

    International Nuclear Information System (INIS)

    Halbritter, J.

    1997-01-01

    Theory and experiment in tunneling are still qualitative in nature, which hold true also for the latest developments in direct-, resonant-, coherent- and incoherent-tunneling. Those tunnel processes have recently branched out of the field of ''solid state tunnel junctions'' into the fields of scanning tunnel microscopy (STM), single electron tunneling (SET) and semiconducting resonant tunnel structures (RTS). All these fields have promoted the understanding of tunneling in different ways reaching from the effect of coherence, of incoherence and of charging in tunneling, to spin flip or inelastic effects. STM allows not only the accurate measurements of the tunnel current and its voltage dependence but, more importantly, the easy quantification via the (quantum) tunnel channel conductance and the distance dependence. This new degree of freedom entering exponentially the tunnel current allows an unique identification of individual tunnel channels and their quantification. In STM measurements large tunnel currents are observed for large distances d > 1 nm explainable by intermediate state tunneling. Direct tunneling with its reduced tunnel time and reduced off-site Coulomb charging bridges distances below 1 nm, only. The effective charge transfer process with its larger off-site and on-site charging at intermediate states dominates tunnel transfer in STM, biology and chemistry over distances in the nm-range. Intermediates state tunneling becomes variable range hopping conduction for distances larger than d > 2 nm, for larger densities of intermediate states n 1 (ε) and for larger temperatures T or voltages U, still allowing high resolution imaging

  12. Avascular osteonecrosis of the femoral condyle after arthroscopic surgery

    International Nuclear Information System (INIS)

    Al-Kaar, M.; Garcia, J.; Fritschy, D.; Bonvin, J.C.

    1997-01-01

    Avascular osteonecrosis of the femoral condyle after arthroscopic surgery. Retrospective review of 10 patients who presented with avascular necrosis of the ipsilateral femoral condyle following arthroscopic meniscectomy (9 medial, 1 lateral). The bone lesions were evaluated by radiography and MRI, which were repeated for few patients. MRI allows earlier diagnosis of avascular necrosis of the femoral condyle and offers an evaluation of extent of the lesions whose evolution is variable: 3 patients required a knee prosthesis, the other 7 patients were treated medically. (authors)

  13. Research and advancement of treating avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Wang Kaibing; Bai Bin; Wang Honghui; Sui Hong

    2006-01-01

    To undertake retrospective analysis of the research and advancement of treating avascular necrosis of the femoral head. After comparing the superiority and inferiority of different treatments and the present therapeutic status many therapeutic methods for avascular necrosis of the femoral head have been performed, commonly according to the staging of necrosis. Conservative therapy is suitable for stage 0-I, interventional therapy is suitable for stage II-III, operation is adapted for stage II-III and femoral head collapse or degenerative changes. Avascular necrosis of the femoral head is a chronic and dysfunctional illness. Comprehensive treatment according to different stage is now the most popular. Interventional therapy is the study focus of the avascular necrosis of the femoral head meanwhile. (authors)

  14. A Method of Accurate Bone Tunnel Placement for Anterior Cruciate Ligament Reconstruction Based on 3-Dimensional Printing Technology: A Cadaveric Study.

    Science.gov (United States)

    Ni, Jianlong; Li, Dichen; Mao, Mao; Dang, Xiaoqian; Wang, Kunzheng; He, Jiankang; Shi, Zhibin

    2018-02-01

    To explore a method of bone tunnel placement for anterior cruciate ligament (ACL) reconstruction based on 3-dimensional (3D) printing technology and to assess its accuracy. Twenty human cadaveric knees were scanned by thin-layer computed tomography (CT). To obtain data on bones used to establish a knee joint model by computer software, customized bone anchors were installed before CT. The reference point was determined at the femoral and tibial footprint areas of the ACL. The site and direction of the bone tunnels of the femur and tibia were designed and calibrated on the knee joint model according to the reference point. The resin template was designed and printed by 3D printing. Placement of the bone tunnels was accomplished by use of templates, and the cadaveric knees were scanned again to compare the concordance of the internal opening of the bone tunnels and reference points. The twenty 3D printing templates were designed and printed successfully. CT data analysis between the planned and actual drilled tunnel positions showed mean deviations of 0.57 mm (range, 0-1.5 mm; standard deviation, 0.42 mm) at the femur and 0.58 mm (range, 0-1.5 mm; standard deviation, 0.47 mm) at the tibia. The accuracy of bone tunnel placement for ACL reconstruction in cadaveric adult knees based on 3D printing technology is high. This method can improve the accuracy of bone tunnel placement for ACL reconstruction in clinical sports medicine. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  15. Imaging appearance of entrapped periosteum within a distal femoral Salter-Harris II fracture

    International Nuclear Information System (INIS)

    Chen, Johnathan; Abel, Mark F.; Fox, Michael G.

    2015-01-01

    Salter Harris II fractures of the distal femur are associated with a high incidence of complications, especially premature physeal closure. Many risk factors for this high rate of premature physeal closure have been proposed. More recently, entrapment of periosteum within the physis has been suggested as an additional predisposing factor for premature physeal closure. The radiographic diagnosis of entrapped soft tissues, including periosteum, can be suggested in the setting of a Salter-Harris II fracture when the fracture does not reduce and physeal widening >3 mm remains. We report a patient who sustained a distal femoral Salter-Harris II fracture following a valgus injury. The patient had persistent distal medial physeal widening >5 mm following attempted reduction. A subsequent MRI revealed a torn periosteum entrapped within the distal femoral physis. Following removal of the periosteum, the patient developed a leg length discrepancy which required physiodesis of the contralateral distal femur. We present this case to raise awareness of the importance of having a high index of suspicion of periosteal entrapment in the setting of Salter-Harris II fractures since most consider entrapped periosteum an indication for surgery. (orig.)

  16. Influence of Coherent Tunneling and Incoherent Hopping on the Charge Transfer Mechanism in Linear Donor-Bridge-Acceptor Systems.

    Science.gov (United States)

    Li, Guangqi; Govind, Niranjan; Ratner, Mark A; Cramer, Christopher J; Gagliardi, Laura

    2015-12-17

    The mechanism of charge transfer has been observed to change from tunneling to hopping with increasing numbers of DNA base pairs in polynucleotides and with the length of molecular wires. The aim of this paper is to investigate this transition by examining the population dynamics using a tight-binding Hamiltonian with model parameters to describe a linear donor-bridge-acceptor (D-B-A) system. The model includes a primary vibration and an electron-vibration coupling at each site. A further coupling of the primary vibration with a secondary phonon bath allows the system to dissipate energy to the environment and reach a steady state. We apply the quantum master equation (QME) approach, based on second-order perturbation theory in a quantum dissipative system, to examine the dynamical processes involved in charge-transfer and follow the population transfer rate at the acceptor, ka, to shed light on the transition from tunneling to hopping. With a small tunneling parameter, V, the on-site population tends to localize and form polarons, and the hopping mechanism dominates the transfer process. With increasing V, the population tends to be delocalized and the tunneling mechanism dominates. The competition between incoherent hopping and coherent tunneling governs the mechanism of charge transfer. By varying V and the total number of sites, we also examine the onset of the transition from tunneling to hopping with increasing length.

  17. Femoral artery pseudoaneurysm as a complication of angioplasty. How can it be prevented?

    Science.gov (United States)

    Gupta, Prabha Nini; Salam Basheer, Abdul; Sukumaran, Gireesh Gomaty; Padmajan, Sabin; Praveen, Satheesan; Velappan, Praveen; Nair, Bigesh Unnikrishnan; Nair, Sandeep Govindan; Kunjuraman, Usha Kumari; Madthipat, Unnikrishnan; R, Jayadevan

    2013-01-01

    Femoral pseudoaneurysm is a common complication of repeated femoral puncture during cardiac catheterisation. We describe here the development of femoral pseudoaneurysms in a patient with Takayasu's arteritis, which healed in response to conservative treatment, and review the literature on the prevention and treatment of femoral pseudoaneurysm. PMID:27326111

  18. Effects of polymer corrosion inhibitor on widening etch tunnels of aluminum foil for capacitor

    International Nuclear Information System (INIS)

    Ban, Chaolei; He, Yedong; Shao, Xin; Wang, Zhishen

    2014-01-01

    Highlights: •With PSSA, the exterior surface dissolution of etched Al foil is suppressed. •With PSSA, the interior surface dissolution of etched Al foil is facilitated. •With PSSA, the tunnels are widened along the entire length. •With PSSA, the area and capacitance of etched Al foil are significantly improved. -- Abstract: We investigated the effects of polymeric corrosion inhibitor polystyrene sulfonic acid (PSSA) additive to 3% HNO 3 solution on widening tunnels of pre-etched aluminum foil by electrochemical DC etching for aluminum electrolytic capacitors, using scanning electron microscopy and polarization curves. With trace PSSA, the dissolution of exterior surface of etch tunnels of Al foil is suppressed and the dissolution of interior surface of etch tunnels of Al foil is facilitated, respectively. The tunnels transform from circular cone to circular column in shape and pits-merging on the surface is weakened, leading to significant increase in the surface area and specific capacitance of the Al foil. The amounts of reduced thickness and weight of Al foil during the widening process of etch tunnels can be decreased if PSSA is employed

  19. Force and light tuning vertical tunneling current in the atomic layered MoS2.

    Science.gov (United States)

    Li, Feng; Lu, Zhixing; Lan, Yann-Wen; Jiao, Liying; Xu, Minxuan; Zhu, Xiaoyang; Zhang, Xiankun; Wu, Hualin; Qi, Junjie

    2018-07-06

    In this work, the vertical electrical transport behavior of bilayer MoS 2 under the coupling of force and light was explored by the use of conductive atomic force microscopy. We found that the current-voltage behavior across the tip-MoS 2 -Pt junction is a tunneling current that can be well fitted by a Simmons approximation. The transport behavior is direct tunneling at low bias and Fowler-Nordheim tunneling at high bias, and the transition voltage and tunnel barrier height are extracted. The effect of force and light on the effective band gap of the junction is investigated. Furthermore, the source-drain current drops surprisingly when we continually increase the force, and the dropping point is altered by the provided light. This mechanism is responsible for the tuning of tunneling barrier height and width by force and light. These results provide a new way to design devices that take advantage of ultrathin two-dimensional materials. Ultrashort channel length electronic components that possess tunneling current are important for establishing high-efficiency electronic and optoelectronic systems.

  20. Femoral head epiphysis growth and development among Chinese children aged 0-5 years.

    Science.gov (United States)

    Luo, Jiayou; Tang, Jin; Zhou, Libo; Zeng, Rong; Mou, Jinsong; Zhang, Lingli

    2009-05-01

    The aim of this study was to examine the pattern of femoral head epiphysis growth and development among Chinese children. Between January and December, 2007, we randomly sampled 1,450 healthy Chinese children (0-5 years old) from Hunan Provincial Children's Hospital in Changsha, Hunan, China. The diameter of femoral head epiphysis was measured by pelvic X-ray photography and processed by medical image processing software. The growth of femoral head epiphysis in girls was 2-3 months earlier than that in boys. The diameter of femoral head epiphysis increased with advancing age in both girls and boys, but the diameter of femoral head epiphysis in 2, 3, 4, 6, and 10-month-old girls was significantly larger than that in boys. Cubic regression equations between the diameter of femoral head epiphysis and age were created for boys and girls that could be used to predict the diameter of femoral head epiphysis. In conclusion, there was gender difference in femoral head epiphysis growth and development among Chinese children, and our prediction models will provide the guidance for early diagnosis of diseases related to the growth and development of the femoral head epiphysis.

  1. Preoperative sup(99m)Tc-MDP scintimetry of femoral neck fractures

    International Nuclear Information System (INIS)

    Holmberg, S.; Thorngren, K.-G.

    1984-01-01

    Preoperative sup(99m)Tc-MDP-scintimetry was performed in 117 patients with femoral neck fractures. Scintimetry was shown to be superior to visual evaluation. The ratio was calculated of the uptake in the femoral head of the fractured side over that in the unfractured side, with compensation for the increased trochanteric femoral activity found on the fractured side. A ratio above 0.90 correlated well with uneventful healing in both undisplaced and displaced fractures. Preoperative scintimetry is of great value in the choice of primary treatment of femoral neck fractures. (author)

  2. Case report - curved femoral osteotomy for management of medial patellar luxation

    DEFF Research Database (Denmark)

    Allpass, Maja; Miles, James Edward

    2015-01-01

    Medial patellaluxation kan forårsages af femoral varus hos hund. Førhen har patienter med excessiv femoralvarus været korrigeret ved en lateralt placeret femoral kile-ostektomi. Her præsenteres en case, hvor en buet osteotomi blev anvendt til behandling af medial patellaluxation.......Medial patellaluxation kan forårsages af femoral varus hos hund. Førhen har patienter med excessiv femoralvarus været korrigeret ved en lateralt placeret femoral kile-ostektomi. Her præsenteres en case, hvor en buet osteotomi blev anvendt til behandling af medial patellaluxation....

  3. The impact of high total cholesterol and high low-density lipoprotein on avascular necrosis of the femoral head in low-energy femoral neck fractures.

    Science.gov (United States)

    Zeng, Xianshang; Zhan, Ke; Zhang, Lili; Zeng, Dan; Yu, Weiguang; Zhang, Xinchao; Zhao, Mingdong; Lai, Zhicheng; Chen, Runzhen

    2017-02-17

    Avascular necrosis of the femoral head (AVNFH) typically constitutes 5 to 15% of all complications of low-energy femoral neck fractures, and due to an increasingly ageing population and a rising prevalence of femoral neck fractures, the number of patients who develop AVNFH is increasing. However, there is no consensus regarding the relationship between blood lipid abnormalities and postoperative AVNFH. The purpose of this retrospective study was to investigate the relationship between blood lipid abnormalities and AVNFH following the femoral neck fracture operation among an elderly population. A retrospective, comparative study was performed at our institution. Between June 2005 and November 2009, 653 elderly patients (653 hips) with low-energy femoral neck fractures underwent closed reduction and internal fixation with cancellous screws (Smith and Nephew, Memphis, Tennessee). Follow-up occurred at 1, 6, 12, 18, 24, 30, and 36 months after surgery. Logistic multi-factor regression analysis was used to assess the risk factors of AVNFH and to determine the effect of blood lipid levels on AVNFH development. Inclusion and exclusion criteria were predetermined to focus on isolated freshly closed femoral neck fractures in the elderly population. The primary outcome was the blood lipid levels. The secondary outcome was the logistic multi-factor regression analysis. A total of 325 elderly patients with low-energy femoral neck fractures (AVNFH, n = 160; control, n = 165) were assessed. In the AVNFH group, the average TC, TG, LDL, and Apo-B values were 7.11 ± 3.16 mmol/L, 2.15 ± 0.89 mmol/L, 4.49 ± 1.38 mmol/L, and 79.69 ± 17.29 mg/dL, respectively; all of which were significantly higher than the values in the control group. Logistic multi-factor regression analysis showed that both TC and LDL were the independent factors influencing the postoperative AVNFH within femoral neck fractures. This evidence indicates that AVNFH was significantly

  4. Outcomes of trochanteric femoral fractures treated with proximal femoral nail: an analysis of 100 consecutive cases

    Directory of Open Access Journals (Sweden)

    Korkmaz MF

    2014-04-01

    Full Text Available Mehmet Fatih Korkmaz,1 Mehmet Nuri Erdem,2 Zeliha Disli,3 Engin Burak Selcuk,4 Mustafa Karakaplan,1 Abdullah Gogus5 1Department of Orthopedics and Traumatology, Inonu University School of Medicine, Malatya, Turkey; 2Department of Orthopedics and Traumatology, Nisantasi University School of Medicine, Istanbul, Turkey; 3Department of Anesthesiology, Malatya Government Hospital, Malatya, Turkey; 4Department of Family Medicine, Inonu University School of Medicine, Malatya, Turkey; 5Department of Orthopedics and Traumatology, Florence Nightingale Hospital, Istanbul, Turkey Purpose: In this study, we aimed to report the results of a retrospective study carried out at our institute regarding cases of patients who had suffered proximal femoral fractures between January 2002 and February 2007, and who were treated with a proximal femoral nail. Materials and methods: One hundred consecutive cases were included in the study. A case documentation form was used to obtain intraoperative data including age, sex, mechanism of injury, type of fracture according to Association for Osteosynthesis/Association for the Study of Internal Fixation (AO/ASIF classification and the American Society of Anesthesiologists' (ASA physical status classification (ASA grade. Clinical and radiographic examinations were performed at the time of admission and at the 6th week; subsequent visits were organized on the 3rd month, 6th month, and 12th month, and in patients with longer follow-up and annually postoperatively. The Harris score of hip function was used, and any change in the position of the implants and the progress of the fracture union, which was determined radiologically, was noted. Results: The mean age of the patients was 77.66 years (range: 37–98 years, and the sex distribution was 32 males and 68 females. Seventy-three fractures were reduced by closed means, whereas 27 needed limited open reduction. The mean follow-up time for the study group was 31.3 months (range

  5. Excitation of propagating surface plasmons with a scanning tunnelling microscope.

    Science.gov (United States)

    Wang, T; Boer-Duchemin, E; Zhang, Y; Comtet, G; Dujardin, G

    2011-04-29

    Inelastic electron tunnelling excitation of propagating surface plasmon polaritons (SPPs) on a thin gold film is demonstrated. This is done by combining a scanning tunnelling microscope (STM) with an inverted optical microscope. Analysis of the leakage radiation in both the image and Fourier planes unambiguously shows that the majority (up to 99.5%) of the detected photons originate from propagating SPPs with propagation lengths of the order of 10  µm. The remaining photon emission is localized under the STM tip and is attributed to a tip-gold film coupled plasmon resonance as evidenced by the bimodal spectral distribution and enhanced emission intensity observed using a silver STM tip for excitation.

  6. Excitation of propagating surface plasmons with a scanning tunnelling microscope

    International Nuclear Information System (INIS)

    Wang, T; Boer-Duchemin, E; Zhang, Y; Comtet, G; Dujardin, G

    2011-01-01

    Inelastic electron tunnelling excitation of propagating surface plasmon polaritons (SPPs) on a thin gold film is demonstrated. This is done by combining a scanning tunnelling microscope (STM) with an inverted optical microscope. Analysis of the leakage radiation in both the image and Fourier planes unambiguously shows that the majority (up to 99.5%) of the detected photons originate from propagating SPPs with propagation lengths of the order of 10 μm. The remaining photon emission is localized under the STM tip and is attributed to a tip-gold film coupled plasmon resonance as evidenced by the bimodal spectral distribution and enhanced emission intensity observed using a silver STM tip for excitation.

  7. Excitation of propagating surface plasmons with a scanning tunnelling microscope

    Energy Technology Data Exchange (ETDEWEB)

    Wang, T; Boer-Duchemin, E; Zhang, Y; Comtet, G; Dujardin, G, E-mail: Elizabeth.Boer-Duchemin@u-psud.fr [Institut des Sciences Moleculaire d' Orsay (ISMO), CNRS Universite Paris-Sud, 91405 Orsay (France)

    2011-04-29

    Inelastic electron tunnelling excitation of propagating surface plasmon polaritons (SPPs) on a thin gold film is demonstrated. This is done by combining a scanning tunnelling microscope (STM) with an inverted optical microscope. Analysis of the leakage radiation in both the image and Fourier planes unambiguously shows that the majority (up to 99.5%) of the detected photons originate from propagating SPPs with propagation lengths of the order of 10 {mu}m. The remaining photon emission is localized under the STM tip and is attributed to a tip-gold film coupled plasmon resonance as evidenced by the bimodal spectral distribution and enhanced emission intensity observed using a silver STM tip for excitation.

  8. The Bolmen tunnel project - evaluation of geophysical site investigation methods

    International Nuclear Information System (INIS)

    Stanfors, R.

    1987-12-01

    The report presents geophysical measurements along and adjacent to the tunnel and an evaluation of the ability of the various methods to permit prediction of rock mass parameters of significance to stability and water bearing ability. The evaluation shows that, using airborne electro-magnetic surveys, it was possible to indicate about 80% of alla the zones of weakness more than 50 m wide in the tunnel. Airborne magnetic surveys located about 90% of all dolerite dykes more than 10 m wide. Ground-level VLF and Slingram methods of electro-magnetic measurement indicated 75% and 85% respectively of all zones of weakness more than 50 m wide. Resistivity methods were successfully used to locate clay filled and water-bearing fracture zones. About 75% of the length of tunnel over which resistivity values below 500 ohm m were measured required shotcrete support and pre-grouting. (orig./DG)

  9. Is Assessment of Femoral Head Perfusion During Modified Dunn for Unstable Slipped Capital Femoral Epiphysis an Accurate Indicator of Osteonecrosis?

    Science.gov (United States)

    Novais, Eduardo N; Sink, Ernest L; Kestel, Lauryn A; Carry, Patrick M; Abdo, João C M; Heare, Travis C

    2016-08-01

    The modified Dunn procedure, which is an open subcapital realignment through a surgical dislocation approach, has gained popularity for the treatment of unstable slipped capital femoral epiphysis (SCFE). Intraoperative monitoring of the femoral head perfusion has been recommended as a method of predicting osteonecrosis; however, the accuracy of this assessment has not been well documented. We asked (1) whether intraoperative assessment of femoral head perfusion would help identify hips at risk of developing osteonecrosis; (2) whether one of the four methods of assessment of femoral head perfusion is more accurate (highest area under the curve) at identifying hips at risk of osteonecrosis; and (3) whether specific clinical features would be associated with osteonecrosis occurrence after a modified Dunn procedure for unstable SCFE. Between 2007 and 2014, we performed 29 modified Dunn procedures for unstable SCFE (16 boys, 11 girls; median age, 13 years; range, 8-17 years); two were lost to followup before 1 year. During this period, six patients with unstable SCFE were treated by other procedures. All patients undergoing modified Dunn underwent assessment of epiphyseal perfusion by the presence of active bleeding and/or by intracranial pressure (ICP) monitoring. In the initial five patients perfusion was recorded once, either before dissection of the retinacular flap or after fixation by one of the two methods. In the remaining 22 patients (81%), perfusion was systematically assessed before dissection of the retinacular flap and after fixation by both methods. Minimum followup was 1 year (median, 2.5 years; range, 1-8 years) because osteonecrosis typically develops within the first year after surgery. Patients were assessed for osteonecrosis by the presence of femoral head collapse at radiographs obtained every 3 months during the first year after surgery. Seven (26%) of the 27 patients developed osteonecrosis. Measures of diagnostic accuracy including sensitivity

  10. Proximal focal femoral deficiency: evaluation by MR imaging

    International Nuclear Information System (INIS)

    Biko, David M.; Davidson, Richard; Pena, Andres; Jaramillo, Diego

    2012-01-01

    Proximal focal femoral deficiency (PFFD) is a rare congenital anomaly characterized by abnormal development of the proximal femur. The most common radiographic classification (Aitken) does not evaluate the cartilaginous and soft-tissue abnormalities. To demonstrate MR findings of PFFD focusing on features not seen with radiographs. Nine MR examinations of the hip and femurs of seven children with PFFD were retrospectively reviewed. Imaging was quantitatively and qualitatively assessed comparing the affected limb to the contralateral limb and age-matched controls. The children were classified via the Aitken classification. All children had at least mild acetabular dysplasia, and one type D patient had no acetabulum. MR demonstrated that 4/6 children had labral hypertrophy with a decreased distance from the greater trochanter to the acetabular rim, suggesting impingement (P < 0.05). The proximal femoral physis was abnormal in all cases. The connection between the femoral head and shaft if present was fibrous or fibrocartilaginous. MRI can help in evaluation of PFFD by defining the anatomy. MR demonstrates features of the acetabulum and cartilaginous femoral epiphysis and depicts ligamentous abnormalities of the knee. (orig.)

  11. Proximal focal femoral deficiency: evaluation by MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Biko, David M. [National Naval Medical Center, Department of Radiology, Bethesda, MD (United States); Uniformed Services University of Health Sciences, Department of Radiology and Radiological Sciences, Bethesda, MD (United States); Davidson, Richard [The Children' s Hospital of Philadelphia, Department of Orthopedic Surgery, Philadelphia, PA (United States); Pena, Andres; Jaramillo, Diego [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2012-01-15

    Proximal focal femoral deficiency (PFFD) is a rare congenital anomaly characterized by abnormal development of the proximal femur. The most common radiographic classification (Aitken) does not evaluate the cartilaginous and soft-tissue abnormalities. To demonstrate MR findings of PFFD focusing on features not seen with radiographs. Nine MR examinations of the hip and femurs of seven children with PFFD were retrospectively reviewed. Imaging was quantitatively and qualitatively assessed comparing the affected limb to the contralateral limb and age-matched controls. The children were classified via the Aitken classification. All children had at least mild acetabular dysplasia, and one type D patient had no acetabulum. MR demonstrated that 4/6 children had labral hypertrophy with a decreased distance from the greater trochanter to the acetabular rim, suggesting impingement (P < 0.05). The proximal femoral physis was abnormal in all cases. The connection between the femoral head and shaft if present was fibrous or fibrocartilaginous. MRI can help in evaluation of PFFD by defining the anatomy. MR demonstrates features of the acetabulum and cartilaginous femoral epiphysis and depicts ligamentous abnormalities of the knee. (orig.)

  12. Five years' experience of transverse groin incision for femoral artery access in arterial reconstructive surgery: parallel observational longitudinal group comparison study.

    LENUS (Irish Health Repository)

    Beirne, Christopher

    2008-07-01

    Vertical groin incisions (VGIs) have been used to access femoral vessels, but reports allude to wound complications. Our aim was to compare VGI with transverse groin incision (TGI) for femoral artery exposure. Over a 5-year interval, 196 patients with 284 femoral artery exposures for supra- and infrainguinal procedures were studied. Primary endpoints were surgical skin site wound infection, seroma, haematoma formation, and major lower limb amputation. Secondary endpoints were graft patency, wound paresthesias, and length of hospital stay. There were 160 TGIs and 124 VGIs. The demographics and risk factor profile were not statistically different between groups. Seroma developed in 4.4% of TGIs and 13.7% of VGIs (p= .005). The complicated skin and soft tissue infection rate was five times greater with VGI (p= .001). The VGI group had a significantly higher rate of major amputation (p= .0005). Significantly higher graft failure rates were observed in the VGI group (p= .011). No paresthesia was reported in any TGI wound. The mean hospital stay was also significantly shorter in the TGI group (p= .006). The study data support and expound on the theory that an alternative incision to VGI offers lower short- and long-term morbidity. Our findings sustain the selection of the TGI in femoral artery surgery for both supra- and infrainguinal procedures without compromise of vessel exposure.

  13. Reoperation Rates for Laparoscopic vs Open Repair of Femoral Hernias in Denmark

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Bisgaard, Thue; Kehlet, Henrik

    2014-01-01

    IMPORTANCE: In Denmark approximately 10 000 groin hernias are repaired annually, of which 2% to 4% are femoral hernias. Several methods for repair of femoral hernias are used including sutured repair and different types of mesh repair with either open or laparoscopic techniques. The use of many...... laparoscopic vs open femoral hernia repair, analyzing data from a nationwide database. DESIGN, SETTING, AND PARTICIPANTS: A prospective cohort study was conducted. Data on femoral hernia repairs registered in the Danish Hernia Database from January 1998 until February 2012 were extracted and analyzed. All...... repairs were followed in the database and analyzed for reports of reoperation, which were used as a proxy for recurrence. Femoral hernia recurrence and inguinal hernia occurrence after the index repair were analyzed. EXPOSURE: Repair of a femoral hernia. MAIN OUTCOMES AND MEASURES: Reoperation...

  14. Evaluation of femoral head vascularization in slipped capital femoral epiphysis before and after cannulated screw fixation with use of contrast-enhanced MRI: initial results

    International Nuclear Information System (INIS)

    Staatz, G.; Honnef, D.; Hohl, C.; Schmidt, T.; Guenther, R.W.; Kochs, A.; Roehrig, H.

    2007-01-01

    In this study we used contrast-enhanced magnetic resonance imaging (MRI) to evaluate the vascularization of the femoral head in children with slipped capital femoral epiphysis (SCFE) before and after cannulated screw fixation. Eleven consecutive children with SCFE, seven boys and four girls, aged 10-15 years were included in the study. There were no preslips; four children had acute, three acute-on-chronic, and four chronic SCFE. The MRI examinations were performed in a 1.5 Tesla MR scanner with use of a coronal STIR sequence, a coronal contrast-enhanced T1-weighted spin-echo sequence, and a sagittal three-dimensional gradient-echo sequence. Morphology, signal intensities, and contrast-enhancement of the femoral head were assessed by two radiologists in consensus. Morphologic distortion of the physis, bone marrow edema within the metaphysis and epiphysis, and joint effusion were the preoperative MRI findings of SCFE in each child. In nine children, the vascularization of the femoral head before and after surgery was normal. In one child, a preoperative avascular zone in the superolateral aspect of the epiphysis revascularized completely after surgery. One child with severe SCFE developed avascular necrosis of the femoral head after open reduction of the slip. We conclude that MRI allows for accurate evaluation of the femoral head vascularization before and after surgery in children with SCFE. (orig.)

  15. Evaluation of femoral head vascularization in slipped capital femoral epiphysis before and after cannulated screw fixation with use of contrast-enhanced MRI: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Staatz, G. [Friedrich-Alexander-University Erlangen-Nuernberg, Department of Radiology, Division of Pediatric Radiology, Erlangen (Germany); University Hospital of the RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Honnef, D.; Hohl, C.; Schmidt, T.; Guenther, R.W. [University Hospital of the RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Kochs, A.; Roehrig, H. [University Hospital of the RWTH Aachen, Department of Orthopaedic Surgery, Aachen (Germany)

    2007-01-15

    In this study we used contrast-enhanced magnetic resonance imaging (MRI) to evaluate the vascularization of the femoral head in children with slipped capital femoral epiphysis (SCFE) before and after cannulated screw fixation. Eleven consecutive children with SCFE, seven boys and four girls, aged 10-15 years were included in the study. There were no preslips; four children had acute, three acute-on-chronic, and four chronic SCFE. The MRI examinations were performed in a 1.5 Tesla MR scanner with use of a coronal STIR sequence, a coronal contrast-enhanced T1-weighted spin-echo sequence, and a sagittal three-dimensional gradient-echo sequence. Morphology, signal intensities, and contrast-enhancement of the femoral head were assessed by two radiologists in consensus. Morphologic distortion of the physis, bone marrow edema within the metaphysis and epiphysis, and joint effusion were the preoperative MRI findings of SCFE in each child. In nine children, the vascularization of the femoral head before and after surgery was normal. In one child, a preoperative avascular zone in the superolateral aspect of the epiphysis revascularized completely after surgery. One child with severe SCFE developed avascular necrosis of the femoral head after open reduction of the slip. We conclude that MRI allows for accurate evaluation of the femoral head vascularization before and after surgery in children with SCFE. (orig.)

  16. Electromigration of single metal atoms observed by scanning tunneling microscopy

    NARCIS (Netherlands)

    Braun, K.-F.; Soe, W.H.; Flipse, C.F.J.

    2007-01-01

    The authors show in this letter that single metal atoms on a Ni(111) surface can be pushed by electromigration forces from a scanning tunneling microscope tip. This repulsive interaction is obsd. over a length scale of 6 nm. While for voltages above -300 mV the atoms are pulled by the microscope

  17. Delayed appearance of hypaesthesia and paralysis after femoral nerve block

    OpenAIRE

    Stefan Landgraeber; Thomas Albrecht; Ulrich Reischuck; Marius von Knoch

    2012-01-01

    We report on a female patient who underwent an arthroscopy of the right knee and was given a continuous femoral nerve block catheter. The postoperative course was initially unremarkable, but when postoperative mobilisation was commenced, 18 hours after removal of the catheter, the patient noticed paralysis and hypaesthesia. Examination confirmed the diagnosis of femoral nerve dysfunction. Colour duplex sonography of the femoral artery and computed tomography of the lumbar spine and pelvis yie...

  18. OUTCOME OF INTERTROCHANTERIC FRACTURES TREATED WITH SHORT FEMORAL NAIL

    Directory of Open Access Journals (Sweden)

    Yadkikar Shriniwas V, Yadkikar Vishnu S, Patel Mayank, Dhruvilkumar Gandhi, Kunkulol Rahul

    2015-07-01

    Full Text Available Aim: To study the functional and anatomical outcome of Inter trochanteric fractures of femur treated with Short femoral nail. Method: This was retrospective study carried out in which 60 patients (50 Male & 10 Female of 5th to 8th decade of life who underwent Short femoral nail fixation for both Stable & unstable Inter Trochanteric fractures. From the records each patient data was assessed for time required for mobilization, average fracture healing time, degree and grade of hip range of movements, complications, anatomical reduction achieved using Short femoral nail fixation. Results: 55 cases achieved Anatomical reduction. Good to Excellent Hip range of Motion was in 55 (90 % cases. Fracture union was seen in all cases. No evidence of Z Effect, AVN of femoral head, Implant failure, Fracture of femoral shaft below the Nail tip was seen in any case, However Reverse Z Effect was seen in 4 & shortening of less than 2 cm was seen in 2 cases, External rotation of 10 degree was seen in1 case. Average fracture Union time was 14 weeks. Conclusion: Short femoral nail appears to be better implant for fixation of both Stable & unstable Inter Trochanteric fractures as it fulfills the biomechanical demands being minimally invasive, less blood loss , it prevents excessive varus collapse at fracture site, produces less stress riser effect below the nail tip, Short operative time, Facilitates early mobilization & functional recovery of patients. But Anatomical fracture reduction & optimal implant placement are absolutely must for better results.

  19. Enhancement of tunneling current in phosphorene tunnel field effect transistors by surface defects.

    Science.gov (United States)

    Lu, Juan; Fan, Zhi-Qiang; Gong, Jian; Chen, Jie-Zhi; ManduLa, Huhe; Zhang, Yan-Yang; Yang, Shen-Yuan; Jiang, Xiang-Wei

    2018-02-21

    The effects of the staggered double vacancies, hydrogen (H), 3d transition metals, for example cobalt, and semiconductor covalent atoms, for example, germanium, nitrogen, phosphorus (P) and silicon adsorption on the transport properties of monolayer phosphorene were studied using density functional theory and non-equilibrium Green's function formalism. It was observed that the performance of the phosphorene tunnel field effect transistors (TFETs) with an 8.8 nm scaling channel length could be improved most effectively, if the adatoms or vacancies were introduced at the source channel interface. For H and P doped devices, the upper limit of on-state currents of phosphorene TFETs were able to be quickly increased to 2465 μA μm -1 and 1652 μA μm -1 , respectively, which not only outperformed the pristine sample, but also met the requirements for high performance logic applications for the next decade in the International Technology Roadmap for Semiconductors (ITRS). It was proved that the defect-induced band gap states make the effective tunneling path between the conduction band (CB) and valence band (VB) much shorter, so that the carriers can be injected easily from the left electrode, then transfer to the channel. In this regard, the tunneling properties of phosphorene TFETs can be manipulated using surface defects. In addition, the effects of spin polarization on the transport properties of doped phosphorene TFETs were also rigorously considered, H and P doped TFETs could achieve a high ON current of 1795 μA μm -1 and 1368 μA μm -1 , respectively, which is closer to realistic nanodevices.

  20. Evaluation of a patient specific femoral alignment guide for hip resurfacing.

    Science.gov (United States)

    Olsen, Michael; Naudie, Douglas D; Edwards, Max R; Sellan, Michael E; McCalden, Richard W; Schemitsch, Emil H

    2014-03-01

    A novel alternative to conventional instrumentation for femoral component insertion in hip resurfacing is a patient specific, computed tomography based femoral alignment guide. A benchside study using cadaveric femora was performed comparing a custom alignment guide to conventional instrumentation and computer navigation. A clinical series of twenty-five hip resurfacings utilizing a custom alignment guide was conducted by three surgeons experienced in hip resurfacing. Using cadaveric femora, the custom guide was comparable to conventional instrumentation with computer navigation proving superior to both. Clinical femoral component alignment accuracy was 3.7° and measured within ± 5° of plan in 20 of 24 cases. Patient specific femoral alignment guides provide a satisfactory level of accuracy and may be a better alternative to conventional instrumentation for initial femoral guidewire placement in hip resurfacing. Crown Copyright © 2014. All rights reserved.

  1. MR evaluation of the articular cartilage of the femoral head during traction. Correlation with resected femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, K. [Osaka Seamens Insurance Hospital (Japan). Dept. of Radiology; Tanaka, H.; Narumi, Y.; Nakamura, H. [Osaka Univ. Medical School (Japan). Dept. of Radiology; Nishii, T.; Masuhara, K. [Osaka Univ. Medical School (Japan). Dept. of Orthopedic Surgery

    1999-01-01

    Objective: The purpose was to evaluate the articular cartilage of the hip joint with MR during traction and compare the findings with the resected specimen or arthroscopic findings. Material and Methods: Eight healthy volunteers, 5 patients with osteonecrosis, 5 with acetabular dysplasia, and 5 with advanced osteoarthrosis underwent MR imaging to evaluate the articular cartilage of the hip joint. Coronal fat-suppressed 3D spoiled gradient-echo (SPGR) images were obtained during traction. Identical imaging was performed of all the resected femoral heads of the osteonecrosis and advanced osteoarthrosis patients, and was correlated with the macroscopic pathological findings. Results: The traction was effective and the femoral articular cartilage was clearly identified in all 8 control subjects, and in all cases of osteonecrosis and acetabular dysplasia. In 4 cases of osteonecrosis, chondral fracture was identified in the boundary between the necrosis and the normal area. In all cases of advanced osteoarthrosis, cartilage was identified only at the medial side. The MR images of osteonecrosis and advanced osteoarthrosis corresponded well with the MR images of the resected femoral heads and the macroscopic findings. (orig.)

  2. Monitoring pilot projects on bored tunnelling : The Second Heinenoord Tunnel and the Botlek Rail Tunnel

    NARCIS (Netherlands)

    Bakker, K.J.; De Boer, F.; Admiraal, J.B.M.; Van Jaarsveld, E.P.

    1999-01-01

    Two pilot projects for bored tunnelling in soft soil have been undertaken in the Netherlands. The monitoring was commissioned under the authority of the Centre for Underground Construction (COB). A description of the research related to the Second Heinenoord Tunnel and the Botlek Rail Tunnel will be

  3. Dynamic gadolinium-enhanced MRI evaluation of porcine femoral head ischemia and reperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T. [Clinic for Orthopaedics and Sports Traumatology, Dreifaltigkeits-Krankenhaus GmbH, Aachener Str. 445-449, 50933 Koeln (Germany); Drescher, W. [Department of Orthopaedics, Christian Albrechts University, Kiel (Germany); Becker, C. [Department of Orthopaedics, Heinrich Heine University, Duesseldorf (Germany); Sangill, R.; Stoedkilde-Joergensen, H. [Institute for Magnetic Resonance Imaging Tomography, University of Aarhus, Skejby Hospital, Aarhus (Denmark); Heydthausen, M. [Computing Center, Heinrich Heine University, Duesseldorf (Germany); Hansen, E.S.; Buenger, C. [Spine Section, Department of Orthopaedics, University of Aarhus (Denmark)

    2003-02-01

    To examine the potential of gadolinium (Gd)-enhanced dynamic MRI in the detection of early femoral head ischemia. Furthermore, to apply a three-compartment model to achieve a clinically applicable MR index for femoral head perfusion during the steady state and arterial hip joint tamponade.Design and materials In a porcine model femoral head perfusion was measured by radioactive tracer microspheres and by using a dynamic Gd-enhanced MRI protocol. Femoral head perfusion measurements and MRI tests were performed unilaterally before, during and after the experimentally induced ischemia of one of the hip joints. Ischemia was induced by increasing intra-articular pressure to 250 mmHg. All pigs showed ischemia of the femoral head epiphysis under hip joint tamponade followed by reperfusion to the same level as before joint tamponade. In two cases perfusion after removal of tamponade continued to be low. In dynamic MRI measurements increases in signal intensity were seen after intravenous infusion of Gd-DTPA, followed by a slow decrease in signal intensity. The signal-intensity curve during femoral head ischemia had a minor increase. Also the coefficient determined was a helpful indicator of femoral head ischemia. Femoral head blood flow as measured by microspheres fell significantly under joint tamponade. Early detection of this disturbed regional blood flow was possible using a dynamic MRI procedure. A biomathematical model resulted from the evaluation of the intervals of signal intensity over time which allows detection of bone blood flow changes at a very early stage. Using this new method earlier detection of femoral head necrosis may be possible. (orig.)

  4. Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO on Comminuted Tibial or Femoral Fractures

    Directory of Open Access Journals (Sweden)

    Ali Andalib

    2017-09-01

    Full Text Available Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO, has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were operated with MIPO method in thiscross-sectional study at Alzahra university hospital in 2015. Eleven patients were excluded due to lack of adequatefollow-ups. Patients’data including union time; infection in the fractured site; hip and knee range of motion; and anymalunion or deformities like limb length discrepancy were collected after the surgery in every session.Results: Among 32 femoral and 17 tibial fractures, union was completed in48 patients, while only one patient withfemoral fracture had nonunion. The mean union time was 18.57±2.42 weeks. Femur fractures healed faster than tibia(17.76±2.36 compared to 19±2.37 weeks, respectively, P=0.09. None of the patients suffered from infections or fistula.The range of motion in hip and knee remained intact in approximately all patients. Malunion happened in 3 patients; 100internal rotation in 1 patient; and 1cm limb shortening in 2 patients.Conclusion: According to the result of this study, MIPO is a simple and effective method of fixation with a high rateof union as well as minimal complications for comminuted fractures of long bones. Infection is rare, and malunion orany deformity is infrequent. MIPO appears to be a promising and safe treatment alternative for comminuted fractures.

  5. Valgus Slipped Capital Femoral Epiphysis in Patient with Hypopituitarism

    Directory of Open Access Journals (Sweden)

    Yoshihiro Kotoura

    2017-01-01

    Full Text Available Slipped capital femoral epiphysis (SCFE is a common disease of adolescent and the epiphysis is positioned more posteromedially in relation to the femoral neck shaft with varus SCFE; however, posterolateral displacement of the capital epiphysis, valgus SCFE, occurs less frequently. We report a case of valgus SCFE in a 17-year-old boy with hypopituitarism. After falling down, he experienced difficulty in walking. The radiographs were inconclusive; however three-dimensional computed tomography images showed lateral displacement of the epiphysis on the right femoral head. Valgus SCFE was diagnosed. The patient underwent in situ pinning of both sides. In situ pinning on the left side was performed as a prophylactic pinning because of endocrine abnormalities. At the 1-year follow-up, he could walk without any difficulty and there were no signs of pain. The epiphysis is commonly positioned more posteromedially in relation to the femoral neck shaft with most SCFE, but, in this case, the epiphysis slipped laterally. Differential diagnosis included femoral neck fracture (Delbet-Colonna type 1; however, this was less likely due to the absence of other clinical signs. Therefore, we diagnosed the patient as SCFE. When children complain of leg pain and limp, valgus SCFE that may not be visualized on anteroposterior radiographs needs to be considered.

  6. Aespoe HRL. Experiences of blasting of the TASQ tunnel

    International Nuclear Information System (INIS)

    Olsson, Mats; Niklasson, Bengt; Wilson, Lasse; Andersson, Christer; Christiansson, Rolf

    2004-11-01

    A new tunnel was developed at the Aespoe Hard Rock Laboratory (AHRL) during the spring and summer 2003. The tunnel was specially designed for a rock mechanics experiment, the Aespoe Pillar Stability Experiment (APSE). In this pillar experiment there was a high demand to initiate high in-situ stresses and therefore the tunnel was designed with a large height/ width ratio and with a circular floor. There were high requirements on bore hole precision and of a minimized EDZ (Excavation damaged zone) in the pillar area. This included a maximum borehole deviation of 10 mm/m, a maximum overbreak due to the lookout angle of 0.3 m and an EDZ of 0.3 m. To make a charge control feasible cartridged explosives was prescribed. The initiation was made with Nonel. The last three rounds used electronic initiation to enable studies of possibility to further reduce the EDZ. The collar of the tunnel was very close to installations and shaft and it was very important to avoid fly-rock and vibrations. Special types of stemming were used as well as steel plates and rubber mats. The excavation works was divided in three different phases. The first phase of the tunnel was an ordinary 26 m 2 tunnel. After approximately 30 m a ramp separated the tunnel section into a top heading and a bench, total 33 m 2 . After the last top heading round was excavated and the roof had been reinforced with fibre reinforced shotcrete the bench was taken out with horizontal holes as the third phase. The drilling precision was very good and 95% of all half-pipes fulfilled the demands. The total amount of visible half-pipes in the APSE-tunnel was high and indicated a successful smooth blasting. The EDZ was examined further by cutting slots in the wall and roof. Existing cracks appear very clearly when a dye penetrant is sprayed on the cleaned surface. A typical crack pattern consists of blast cracks, induced cracks (cracks from the distressing caused by blasting) and natural cracks. The maximum crack length in

  7. Aespoe HRL. Experiences of blasting of the TASQ tunnel

    Energy Technology Data Exchange (ETDEWEB)

    Olsson, Mats [Swebrec, Luleaa (Sweden); Niklasson, Bengt [Skanska Teknik, Stockholm (Sweden); Wilson, Lasse [Skanska Stora Projekt, Stockholm (Sweden); Andersson, Christer; Christiansson, Rolf [Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden)

    2004-11-01

    length in the tunnel wall was roughly 0.2 m. However, longer cracks existed but these cracks probably originate from water filled blast holes. The cracks from the bench were generally much shorter than what is normally achieved during excavation of a horse-shoe shaped tunnel. This may be due to the stress situation under the arched bottom profile, the height requirement on drilling precision also in the floor as well as the low confinement in the arch shaped contour of the floor: Some conclusions from the APSE tunnel: There is a demand for new drilling equipment with a better guidance control to increase the drilling accuracy. Electronic detonators have very good accuracy and a high potential to reduce cracks from blasting. However, they must be more easy to use. It is possible to minimize the damage zone in the floor by using top heading and bench. However, there is a demand for more development in order to minimize the damage zone in the floor without a separate bench. Water in bore holes increases the damage zone in terms of length and frequency of induced fractures. This could be avoided by drilling the holes pointing slightly upwards. The look-out angle and distribution of specific charge along each round causes a discontinuous EDZ along the tunnel. It is therefore indicated that the impact of the EDZ on hydraulic conductivity along the tunnel has very limited impact. During similar conditions is it believed that the extent of the EDZ is manageable through DandB design and QA control during excavation.

  8. Outcomes following femoral lengthening: An initial comparison of the Precice intramedullary lengthening nail and the LRS external fixator monorail system.

    Science.gov (United States)

    Laubscher, M; Mitchell, C; Timms, A; Goodier, D; Calder, P

    2016-10-01

    Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages. We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared. In 20 cases (15 patients) the Precice lengthening nail was used and in 13 cases (seven patients) the LRS external fixator system. The desired length was achieved in all cases in the Precice group and in 12 of 13 cases in the LRS group. The mean healing index was 31.3 days/cm in the Precice and 47.1 days/cm in the LRS group (p < 0.001). This was associated with an earlier ability to bear full weight without aids in the Precice group. There were more complications with LRS lengthening, including pin site infections and regenerate deformity. Implant tolerance and the patients' perception of the cosmetic result were better with the Precice treatment. Femoral lengthening with the Precice femoral nail achieved excellent functional results with fewer complications and greater patient satisfaction when compared with the LRS system in our patients. Cite this article: Bone Joint J 2016;98-B:1382-8. ©2016 The British Editorial Society of Bone & Joint Surgery.

  9. Compartment Syndrome following Open Femoral Fracture with an Isolated Femoral Vein Injury Treated with Acute Repair

    Directory of Open Access Journals (Sweden)

    David Walmsley

    2014-01-01

    Full Text Available Acute compartment syndrome is a surgical emergency and its diagnosis is more difficult in obtunded or insensate patients. We present the case of a 34-year-old woman who sustained a Gustilo-Anderson grade III open midshaft femur fracture with an isolated femoral vein injury treated with direct repair. She developed lower leg compartment syndrome at 48 hours postoperatively, necessitating fasciotomies. She was subsequently found to have a DVT in her femoral vein at the level of the repair and was started on therapeutic anticoagulation. This case highlights the importance of recognition of isolated venous injuries in a trauma setting as a risk factor for developing compartment syndrome.

  10. Protein Tunnels: The Case of Urease Accessory Proteins.

    Science.gov (United States)

    Musiani, Francesco; Gioia, Dario; Masetti, Matteo; Falchi, Federico; Cavalli, Andrea; Recanatini, Maurizio; Ciurli, Stefano

    2017-05-09

    Transition metals are both essential micronutrients and limited in environmental availability. The Ni(II)-dependent urease protein, the most efficient enzyme known to date, is a paradigm for studying the strategies that cells use to handle an essential, yet toxic, metal ion. Urease is a virulence factor of several human pathogens, in addition to decreasing the efficiency of soil organic nitrogen fertilization. Ni(II) insertion in the urease active site is performed through the action of three essential accessory proteins: UreD, UreF, and UreG. The crystal structure of the UreD-UreF-UreG complex from the human pathogen Helicobacter pylori (HpUreDFG) revealed the presence of tunnels that cross the entire length of both UreF and UreD, potentially able to deliver Ni(II) ions from UreG to apo-urease. Atomistic molecular dynamics simulations performed on the HpUreDFG complex in explicit solvent and at physiological ionic conditions demonstrate the stability of these protein tunnels in solution and provide insights on the trafficking of water molecules inside the tunnels. The presence of different alternative routes across the identified tunnels for Ni(II) ions, water molecules, and carbonate ions, all involved in urease activation, is highlighted here, and their potential role in the urease activation mechanism is discussed.

  11. [Arthroscopy-guided core decompression and bone grafting combined with selective arterial infusion for treatment of early stage avascular necrosis of femoral head].

    Science.gov (United States)

    Guo, Hao-Shan; Tian, Yi-Jun; Liu, Gang; An, Long; Zhou, Zhan-Guo; Liu, Huan-Zhen

    2018-01-25

    To observe the clinical effects of arthroscopy-guided core decompression and bone grafting combined with selective arterial infusion for early stage avascular necrosis of femoral head. From January 2010 to December 2014, 76 patients(76 hips) diagnosed as Ficat II stage avascular necrosis of femoral head were randomly divided into experimental group and control group. In the experimental group, there were 27 males and 8 females aged from 24 to 55 years old with an average of (43.96±6.81) years, treated with arthroscopic-guided core decompression and bone grafting combined with selective arterial infusion. Along the direction of the femoral neck, an 8 mm-diameter tunnel to necrotic areas was drilled, then curettage of necrotic bone was performed under arthroscope, and the iliac bone was grafted. In the control group, there were 29 males and 12 females aged from 26 to 56 years old with an average of (44.62±7.33) years, treated with percutaneous core decompression combined with selective arterial infusion. The preoperative and postoperative Harris scores were recorded and the changes of X-rays were analyzed. All the patients were followed up with an average of 30 months. Postoperative follow-up at 12 months showed that there was significant difference in imaging outcome between two groups( P 0.05), but there was significant difference in postoperative Harris score( P necrosis are effective. Using arthroscopic-guided core decompression method, the necrotic bone can be positioned and scraped more accurately, and can obtain better results. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  12. Stem cell treatment for avascular necrosis of the femoral head: current perspectives

    Directory of Open Access Journals (Sweden)

    Houdek MT

    2014-04-01

    Full Text Available Matthew T Houdek,1 Cody C Wyles,2 John R Martin,1 Rafael J Sierra11Department of Orthopedic Surgery, 2School of Medicine, Mayo Clinic, Rochester, MN, USAAbstract: Avascular necrosis (AVN of the femoral head is a progressive disease that predominantly affects younger patients. Although the exact pathophysiology of AVN has yet to be elucidated, the disease is characterized by a vascular insult to the blood supply of the femoral head, which can lead to collapse of the femoral head and subsequent degenerative changes. If AVN is diagnosed in the early stages of the disease, it may be possible to attempt surgical procedures which preserve the hip joint, including decompression of the femoral head augmented with concentrated bone marrow. The use of autologous stem cells has shown promise in halting the progression of AVN of the femoral head, and subsequently preventing young patients from undergoing total hip arthroplasty. The purpose of this study was to review the current use of stem cells for the treatment of AVN of the femoral head.Keywords: avascular necrosis, femoral head, osteonecrosis, stem cells, concentrated bone marrow

  13. MR imaging of femoral marrow in treated β-thalassemia major

    International Nuclear Information System (INIS)

    Shen Jun; Liang Biling; Chen Jianyu; Zhao Jiquan; Xu Honggui; Chen Chun

    2006-01-01

    Objective: To investigate MR imaging features of femoral marrow in treated β-thalassemia major. Methods: MR imaging of the proximal femoral marrow was performed in 35 cases of β-thalassemia major and 45 age- and sex-matched normal children as control. Coronal images of femoral marrow with the techniques of spin echo and fast field echo (FFE) were obtained. On T 1 -weighted imaging the red and yellow femoral marrow were judged and marrow distribution was classified into five groups. The hemosiderosis of marrow was judged on the basis of signal intensity of marrow on FFE imaging. The marrow distribution classification and the hemosiderosis on MR imaging were correlated with clinical features. Results: On FFE, marrow hemosiderosis occurred in 15 patients with a marked hypo-intensity signal and was related to the age (P=0.032). On T 1 -weighted imaging, the femoral marrow in 35 patients was classified as group III and IV, while the marrow distribution was group I or II in all normal children, there was statistically significant difference (P<0.001). The marrow distribution correlated positively with blood transfusion (P=0.049). Conclusion: The red marrow hyperplasia and hemosiderosis could occur in the femoral marrow of the treated β-thalassemia major. The marrow hyperplasia on MR imaging was related to the blood transfusion, and the hemosiderosis related to the age. (authors)

  14. Epidemiology of metatarsal stress fractures versus tibial and femoral stress fractures during elite training.

    Science.gov (United States)

    Finestone, Aharon; Milgrom, Charles; Wolf, Omer; Petrov, Kaloyan; Evans, Rachel; Moran, Daniel

    2011-01-01

    The training of elite infantry recruits takes a year or more. Stress fractures are known to be endemic in their basic training and the clinical presentation of tibial, femoral, and metatarsal stress fractures are different. Stress fracture incidence during the subsequent progressively more demanding training is not known. The study hypothesis was that after an adaptation period, the incidence of stress fractures during the course of 1 year of elite infantry training would fall in spite of the increasingly demanding training. Seventy-six male elite infantry recruits were followed for the development of stress fractures during a progressively more difficult training program composed of basic training (1 to 14 weeks), advanced training (14 to 26 weeks), and unit training (26 to 52 weeks). Subjects were reviewed regularly and those with clinical suspicion of stress fracture were assessed using bone scan and X-rays. The incidence of stress fractures was 20% during basic training, 14% during advanced training and 23% during unit training. There was a statistically significant difference in the incidence of tibial and femoral stress fractures versus metatarsal stress fractures before and after the completion of phase II training at week 26 (p=0.0001). Seventy-eight percent of the stress fractures during phases I and II training were either tibial or femoral, while 91% of the stress fractures in phase III training were metatarsal. Prior participation in ball sports (p=0.02) and greater tibial length (p=0.05) were protective factors for stress fracture. The study hypothesis that after a period of soldier adaptation, the incidence of stress fractures would decrease in spite of the increasingly demanding elite infantry training was found to be true for tibial and femoral fractures after 6 months of training but not for metatarsal stress fractures. Further studies are required to understand the mechanism of this difference but physicians and others treating stress fractures

  15. Osteoarthritis of the patella, lateral femoral condyle and posterior medial femoral condyle correlate with range of motion.

    Science.gov (United States)

    Suzuki, Takashi; Motojima, Sayaka; Saito, Shu; Ishii, Takao; Ryu, Keinosuke; Ryu, Junnosuke; Tokuhashi, Yasuaki

    2013-11-01

    The type of osteoarthritis and the degree of severity which causes restriction of knee range of motion (ROM) is still largely unknown. The objective of this study was to analyse the location and the degree of cartilage degeneration that affect knee range of motion and the connection, if any, between femorotibial angle (FTA) and knee ROM restriction. Four hundreds and fifty-six knees in 230 subjects with knee osteoarthritis undergoing knee arthroplasty were included. Articular surface was divided into eight sections, and cartilage degeneration was evaluated macroscopically during the operation. Cartilage degeneration was classified into four grades based on the degree of exposure of subchondral bone. A Pearson correlation was conducted between FTA and knee flexion angle to determine whether high a degree of FTA caused knee flexion restriction. A logistic regression analysis was also conducted to detect the locations and levels of cartilage degeneration causing knee flexion restriction. No correlation was found between FTA and flexion angle (r = -0.08). Flexion angle was not restricted with increasing FTA. Logistic regression analysis showed significant correlation between restricted knee ROM and levels of knee cartilage degeneration in the patella (odds ratio (OR) = 1.77; P = 0.01), the lateral femoral condyle (OR = 1.62; P = 0.03) and the posterior medial femoral condyle (OR = 1.80; P = 0.03). For clinical relevance, soft tissue release and osteophyte resection around the patella, lateral femoral condyle and posterior medial femoral condyle might be indicated to obtain a higher degree of knee flexion angle.

  16. Femoral neck fractures: A prospective assessment of the pattern ...

    African Journals Online (AJOL)

    OBJECTIVE: To review the pattern of femoral neck fractures, complications and outcome following fixation with Austin-Moore endoprosthesis. METHOD: A two year prospective study in patients who had fracture of the femoral neck based on strict inclusion criteria. All the patients were treated by Austin-Moore ...

  17. 21 CFR 888.3400 - Hip joint femoral (hemi-hip) metallic resurfacing prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic resurfacing... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3400 Hip joint femoral (hemi-hip) metallic resurfacing prosthesis. (a) Identification. A hip joint femoral (hemi-hip...

  18. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femoral (hemi-knee) metallic uncemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint femoral (hemi-knee) metallic uncemented prosthesis. (a) Identification. A knee joint femoral (hemi-knee...

  19. Management of Post-Traumatic Phlegmasia Cerulea Dolens via Right-to-Left Femoral Vein to Femoral Vein Bypass (Palma Procedure).

    Science.gov (United States)

    Dua, Anahita; Heller, Jennifer; Lee, Cheong

    2017-11-01

    Phlegmasia cerulea dolens (PCD) is a rare condition resulting from venous occlusion that impairs arterial flow. We report a rare case of post-traumatic PCD after ligation of the iliac vein with successful treatment by right-to-left femoral vein to femoral vein bypass using left great saphenous vein (Palma procedure). The clinical presentation, diagnostic process, and approach to management along with a literature review on the operative management of PCD are presented in this case report.

  20. Transvenous liver biopsy via the femoral vein

    International Nuclear Information System (INIS)

    Khosa, F.; McNulty, J.G.; Hickey, N.; O'Brien, P.; Tobin, A.; Noonan, N.; Ryan, B.; Keeling, P.W.N.; Kelleher, D.P.; McDonald, G.S.A.

    2003-01-01

    AIM: To study the safety, effectiveness and diagnostic value of transvenous forceps biopsy of the liver in 54 patients with coagulopathy, gross ascites or morbid obesity and suspected liver disease in whom percutaneous liver biopsy was contraindicated. MATERIAL AND METHODS: Forceps biopsy of the liver via the femoral vein was attempted in 54 adult patients with advanced liver disease of unknown aetiology who had coagulation disorders (41 cases), gross ascites (11 cases) or morbid obesity (two cases). In each patient two to six biopsies (average four) were taken using a radial jaw forceps inserted via the right or left femoral vein. RESULTS: The procedure was successful in 53 cases. Hepatic vein catheterization failed in one patient. Adequate liver tissue for diagnosis was obtained in 84% of cases. One patient developed delayed haemorrhage at 12 h from a capsular leak that was undetected during the biopsy procedure. This patient required blood transfusions and laparotomy to control bleeding. There were no deaths in the 53 patients studied. Transient minor chest and shoulder pain was encountered during sheath insertion into a hepatic vein in 23 patients. Three patients developed a femoral vein haematoma, which resolved with conservative treatment. CONCLUSION: Transvenous liver biopsy via the femoral vein is another safe, effective, simple alternative technique of biopsy when the percutaneous route is contraindicated

  1. Hip dislocation following the treatment of femoral neck fracture: Case report

    Directory of Open Access Journals (Sweden)

    Vukašinović Zoran

    2010-01-01

    Full Text Available Introduction. Femoral neck fractures are very rare in young patients and are frequently complicated by femoral head osteonecrosis and femoral neck nonunion. Case Outline. A 19-year-old girl with hip dislocation following the treatment of the femoral neck fracture is presented. The femoral neck fracture was initially treated by open reduction and three-screw fixation. After detecting the nonunion of femoral neck, valgus osteotomy was done. Secondary, iatrogenic, hip dislocation appeared. The patient had pains, and in clinical findings a shorter leg and limited range of motion in the hip - altogether 40 degrees. She was then successfully treated by open reduction, together with Chiari pelvic osteotomy and joint transfixation. Transfixation pin was removed three weeks following the operation. After that, the patient was put into the abduction device and physical therapy was started. The mentioned regimen lasted four months after the surgery, then the abduction device was removed and walking started. Full weight bearing was allowed eight months after surgery. Conclusion. As we have not found the literature data concerning the above mentioned problem, we solved it in the way that we usually do for the treatment of developmental dislocation of the hip in adolescence.

  2. Estimated carotid-femoral pulse wave velocity has similar predictive value as measured carotid-femoral pulse wave velocity

    DEFF Research Database (Denmark)

    Olsen, Michael; Greve, Sara; Blicher, Marie

    2016-01-01

    OBJECTIVE: Carotid-femoral pulse wave velocity (cfPWV) adds significantly to traditional cardiovascular (CV) risk prediction, but is not widely available. Therefore, it would be helpful if cfPWV could be replaced by an estimated carotid-femoral pulse wave velocity (ePWV) using age and mean blood...... pressure and previously published equations. The aim of this study was to investigate whether ePWV could predict CV events independently of traditional cardiovascular risk factors and/or cfPWV. DESIGN AND METHOD: cfPWV was measured and ePWV calculated in 2366 apparently healthy subjects from four age...

  3. The treatment of nonisthmal femoral shaft nonunions with im nail exchange versus augmentation plating.

    Science.gov (United States)

    Park, Jin; Kim, Sul Gee; Yoon, Han Kook; Yang, Kyu Hyun

    2010-02-01

    The purpose of this study was to compare the results between exchange nailing (EN) and augmentation plating (AP) with a nail left in situ for nonisthmal femoral shaft nonunion after femoral nailing. : Retrospective data analysis, November 1996-March 2006. A level I trauma center. Eighteen patients with 18 nonisthmal femoral nonunions. Seven patients with 7 fractures treated for nonisthmal femoral shaft nonunions after femoral nailing with EN and 11 patients with 11 fractures treated for nonisthmal femoral shaft nonunions after nailing with AP combined with bone grafting. Union and complications. Five nonunions in the EN group failed to achieve union (72% failure rate), whereas all 11 pseudarthroses in the AP group obtained osseous union. Fisher exact test showed a higher nonunion rate of EN compared with AP for nonisthmal femoral shaft nonunion (odds ratio, 6.5; P = 0.002). AP with autogenous bone grafting may be a better option than EN for nonisthmal femoral nonunions.

  4. Current indications for open Kuntscher nailing of femoral shaft ...

    African Journals Online (AJOL)

    Current indications for open Kuntscher nailing of femoral shaft fractures. A S Bajwa FCS(SA)ORTH. E Schnaid FCS(SA)ORTH. M E B Sweet MD PhD(rned). University of Witwatersrand, Johannesburg, South Africa. Key Words: Kuntscher nail, intramedullary nail, femoral fracture. We retrospectively reviewed 32 patients with.

  5. Image features of herniation pit of the femoral neck

    International Nuclear Information System (INIS)

    Zhang Xuezhe; Li Guangming; Wang Cunli; Wang Guimin

    2008-01-01

    Objective: To evaluate imaging appearances of herniation pit of the femoral neck. Methods: We retrospectively analyzed the X-ray, CT and MRI findings of 9 patients with herniation pit of the femoral neck. All nine patients were male with the age ranging from 21 to 73 years. They had pain in the hip from two months to two years duration. Results: The bilateral hips were affected in six patients, the right hips in the other 3 patients. Of the nine patients, X-ray plain films (2 cases), CT scanning(6 cases), and MR scanning (5 cases ) were performed. The size of the lesions ranged from 0.5 cm x 0.6 cm to 1.0 cm x 1.5 cm, located in the anterosuperior portion of the femoral neck (n=7) or anteroinferior portion (n=2). X-ray plain films showed an osteolytic lesion surrounded by a sclerotic rim. CT scanning showed the lesion just below the cortex of the femoral neck surrounded by a rim of sclerosis or associated with a small cortical break in two patients. MR scanning showed low signal intensity in five patients on T 1 WI and high signal intensity surrounded by a rim of low signal intensity (n=3) or low signal intensity (n=2) on T 2 WI, and high signal intensity on fat suppression MR image. A small joint effusion was observed in two cases on T 2 WI. Conclusion: The CT and MRI findings of herniation pit of the femoral neck are characteristic, it is useful in defining the diagnosis of the herniation pit of the femoral neck. (authors)

  6. Nonunion of the femoral neck: Possibilities and limitations of the various treatment modalities

    Directory of Open Access Journals (Sweden)

    Raaymakers Ernst

    2008-01-01

    Full Text Available Nowadays in cases of nonunions of the femoral neck, the surgeon is tempted to perform prosthetic replacement of the hip, more so if there is also evidence of avascular necrosis of the head of femur. This provides rapid pain relief and allows early mobilization. However, long-term results of hip arthroplasties, especially in younger people and in the presence of osteopenia, are not always as expected; and a less radical approach is worth considering. The intertrochanteric valgization osteotomy, described by Pauwels, is an excellent alternative for healthy patients up to 65 years of age with a nonunion of the femoral neck. A union rate of 80-90% of the nonunion is described by most authors. Leg length inequallity, rotational and angular deformities can be corrected at the same time. During the period 1973-1995, we performed valgization osteotomy according to Pauwels in 66 patients of, 18-72 years old (mean 49.5 years. 24 (37% of our patients died 4 months to 24 years (mean: 9.5 years after the operation. Union of the femoral neck was achieved in 58 (88% of the 66 patients; union of the osteotomy in 65 patients (99%. A good or excellent result was achieved in 62% (23 uneventful and 13 with healed, necrosis/arthrosis without need for further treatment of our patients. However, the method has its limits. We feel if there is too little bone stock inside the femoral head, a valgization osteotomy does not give good result. The radiographic signs of avascular necrosis in patients over 30 years of age is considered a contraindication for an osteotomy. However our results show that it is worthwhile trying to save the joint of young patients even in case of a segmental collapse. In the race between revascularization and collapse, often revascularization is the winner. We deliberately give nature its chance and don′t rely on the result of bleeding from drill holes in the head, nuclear scans and other methods to estimate vascularity. A secondary total hip

  7. Transtrochanteric rotational osteotomy for avascular necrosis of the femoral head after unstable slipped capital femoral epiphysis: 10-year clinical results.

    Science.gov (United States)

    Nakashima, Yasuharu; Yamamoto, Takuaki; Fukushi, Jun-Ichi; Motomura, Goro; Hamai, Satoshi; Kohno, Yusuke; Iwamoto, Yukihide

    2016-11-01

    Avascular necrosis of the femoral head (AVN) is the most serious complication after unstable slipped capital femoral epiphysis (SCFE), and is often unsalvageable. We report a minimum 10 years of clinical results for transtrochanteric rotational osteotomy of the femoral head (TRO) for AVN. This study included 7 patients (7 hips) with a mean age at surgery of 13.3 years, and the follow-up period was 15.8 years. All patients had prior treatment via closed reduction and pinning of the unstable SCFE, and showed severely collapsed femoral heads. The direction of rotation was anterior in 3 hips and posterior in 4. The Merle d'Aubigné-Postel score (MDPS) was used for clinical assessment, and joint degeneration was assessed with the Kellgren and Lawrence classification (KL-grade). The spherical intact area of the femoral head was moved to the weight-bearing portion, and subluxation was corrected via rotation combined with intentional varus positioning. The mean MDPS improved from 10.3 points to 15.6 points at 5 years, and it was maintained at 15.0 points by 10 years; 3 hips were excellent, 1 was good, 2 were fair, and 1 showed poor outcomes. No patient experienced re-collapse after TRO or required conversion to hip replacement or arthrodesis. After 10 years, degenerative changes became evident over time, and 2 hips progressed to KL-4 with a decreased MDPS. Although some joint degeneration is inevitable in the long-term, TRO is an effective salvage procedure for treating AVN after unstable SCFE. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  8. Hypersonic wind-tunnel free-flying experiments with onboard instrumentation

    KAUST Repository

    Mudford, Neil R.; O'Byrne, Sean B.; Neely, Andrew J.; Buttsworth, David R.; Balage, Sudantha

    2015-01-01

    Hypersonic wind-tunnel testing with "free-flight" models unconnected to a sting ensures that sting/wake flow interactions do not compromise aerodynamic coefficient measurements. The development of miniaturized electronics has allowed the demonstration of a variant of a new method for the acquisition of hypersonic model motion data using onboard accelerometers, gyroscopes, and a microcontroller. This method is demonstrated in a Mach 6 wind-tunnel flow, whose duration and pitot pressure are sufficient for the model to move a body length or more and turn through a significant angle. The results are compared with those obtained from video analysis of the model motion, the existing method favored for obtaining aerodynamic coefficients in similar hypersonic wind-tunnel facilities. The results from the two methods are in good agreement. The new method shows considerable promise for reliable measurement of aerodynamic coefficients, particularly because the data obtained are in more directly applicable forms of accelerations and rates of turn, rather than the model position and attitude obtained from the earlier visualization method. The ideal may be to have both methods operating together.

  9. Tunnel magnetoresistance in asymmetric double-barrier magnetic tunnel junctions

    International Nuclear Information System (INIS)

    Useinov, N.Kh.; Petukhov, D.A.; Tagirov, L.R.

    2015-01-01

    The spin-polarized tunnel conductance and tunnel magnetoresistance (TMR) through a planar asymmetric double-barrier magnetic tunnel junction (DBMTJ) have been calculated using quasi-classical model. In DBMTJ nanostructure the magnetization of middle ferromagnetic metal layer can be aligned parallel or antiparallel with respect to the fixed magnetizations of the top and bottom ferromagnetic electrodes. The transmission coefficients of an electron to pass through the barriers have been calculated in terms of quantum mechanics. The dependencies of tunnel conductance and TMR on the applied voltage have been calculated in case of non-resonant transmission. Estimated in the framework of our model, the difference between the spin-channels conductances at low voltages was found relatively large. This gives rise to very high magnitude of TMR. - Highlights: • The spin-polarized conductance through the junction is calculated. • Dependencies of the tunnel conductance vs applied bias are shown. • Bias voltage dependence of tunnel magnetoresistance for the structure is shown

  10. The Incidence of Atypical Femoral Fractures in Patients with Rheumatic Disease: Yamagata Prefectural Committee of Atypical Femoral Fractures (YamaCAFe) Study.

    Science.gov (United States)

    Takakubo, Yuya; Ohta, Daichi; Ishi, Masaji; Ito, Juji; Oki, Hiroharu; Naganuma, Yasushi; Uno, Tomohiro; Sasaki, Akiko; Akabane, Takeru; Dairaku, Katsuyuki; Goto, Shinichi; Goto, Yasuo; Kanauchi, Yumiko; Kobayashi, Shinji; Nakajima, Taku; Masuda, Keiji; Matsuda, Michiharu; Mura, Nariyuki; Takenouchi, Kenji; Tsuchida, Hiroyuki; Onuma, Yasushi; Shibuya, Junichirou; Seino, Mitsuyoshi; Yamaguchi, Osamu; Hiragami, Ken; Urayama, Yasuhiro; Furukawa, Takashi; Okuda, Shouta; Ogura, Ken; Nakamura, Takeshi; Sasaki, Kan; Konta, Tsuneo; Takagi, Michiaki

    2017-08-01

    Atypical femoral fractures (AFFs) have been reported to occur with minimal or spontaneous subtrochanteric and femoral shaft fractures with a characteristic transverse pattern, compared with typical femoral fractures in young patients with high-energy trauma. AFFs are related to long-term use of bisphosphonates (BPs), glucocorticoids and rheumatic diseases. We have estimated a blind analysis of AFFs in rheumatic patients receiving BPs and glucocorticoids ordinary over a long time in all Yamagata prefectural area through radiographic examination. The 123 AFFs including suspected cases over six years were collected and reviewed by two independent orthopedic surgeons. We found 86 patients with a total of 99 AFFs between 2009 and 2014 (1.43 cases/100,000 person/year). Of these 99 AFFs, 11 were in 8 rheumatic patients including three patients with bilateral AFFs. The incidence of AFFs in rheumatic patients had trend to increase from 2012. The mean age of all 8 patients was 54.9 years. All 8 patients received BPs and 7/8 received prednisolone (PSL). The mean dose of PSL was 14 mg/day. Compared to patients with unilateral AFFs, those with bilateral AFFs in rheumatic patients were on a higher dose of PSL (20 mg/day vs. 7 mg/day) and had less femoral neck-shaft angle (129° vs. 136°, p rheumatic patients showed a trend to increase from 2012 to 2014 in Yamagata prefecture. Careful management of AFFs is of particular importance in rheumatic patients who have taken high doses of PSL and have small femoral neck-shaft angle.

  11. Development of a method for measuring femoral torsion using real-time ultrasound

    International Nuclear Information System (INIS)

    Hafiz, Eliza; Hiller, Claire E; Nightingale, E Jean; Eisenhuth, John P; Refshauge, Kathryn M; Nicholson, Leslie L; Clarke, Jillian L; Grimaldi, Alison

    2014-01-01

    Excessive femoral torsion has been associated with various musculoskeletal and neurological problems. To explore this relationship, it is essential to be able to measure femoral torsion in the clinic accurately. Computerized tomography (CT) and magnetic resonance imaging (MRI) are thought to provide the most accurate measurements but CT involves significant radiation exposure and MRI is expensive. The aim of this study was to design a method for measuring femoral torsion in the clinic, and to determine the reliability of this method. Details of design process, including construction of a jig, the protocol developed and the reliability of the method are presented. The protocol developed used ultrasound to image a ridge on the greater trochanter, and a customized jig placed on the femoral condyles as reference points. An inclinometer attached to the customized jig allowed quantification of the degree of femoral torsion. Measurements taken with this protocol had excellent intra- and inter-rater reliability (ICC 2,1  = 0.98 and 0.97, respectively). This method of measuring femoral torsion also permitted measurement of femoral torsion with a high degree of accuracy. This method is applicable to the research setting and, with minor adjustments, will be applicable to the clinical setting. (paper)

  12. Evaluation of femoral head viability via bone scintigraphy in the postoperative pediatric patient

    International Nuclear Information System (INIS)

    Parikh, Ashishkumar K.; Washington, Eleby R.; Spottswood, Stephanie E.; Bobbey, Adam J.

    2018-01-01

    Evaluating postoperative patients with hardware is challenging following surgical intervention for hip maladies such as femoral neck fractures and slipped capital femoral epiphysis (SCFE). These children are at increased risk of developing avascular necrosis, and imaging may be requested to confirm or exclude this diagnosis. Children with Legg-Calve-Perthes disease can be monitored for restoration of blood flow to the capital femoral epiphysis to guide management and help with prognosis. Although MRI is sensitive for detecting early avascular necrosis, the presence of hardware degrades image quality. This report examines the utility of bone scans for evaluating femoral head perfusion in children who have undergone surgery for femoral neck fractures, SCFE or Legg-Calve-Perthes disease. A retrospective review of 20 patients (22 scans) after fixation for femoral neck fracture, SCFE or Legg-Calve-Perthes disease from 2012 to 2015 was performed. The bone scan findings were correlated with the intraoperative findings or clinical follow-up. Twenty-one of the 22 (95%) bone scans in 19 of the 20 (95%) patients demonstrated findings consistent with clinical outcomes and/or the intraoperative appearance of the femoral head. Four of 20 patients (20%) had bone scan features of avascular necrosis, defined as ''absent'' or ''moderately diminished'' femoral head activity, which were confirmed intraoperatively and resulted in poor outcomes. Radionuclide imaging of hips in the postoperative setting is a valuable modality for assessing the risk of avascular necrosis, a complication of femoral neck fractures and SCFE and for evaluating the restoration of flow to the capital femoral epiphyses of children with Legg-Calve-Perthes disease. (orig.)

  13. Study on Hot Gases Flow in Case of Fire in a Road Tunnel

    Directory of Open Access Journals (Sweden)

    Aleksander Król

    2018-03-01

    Full Text Available This paper presents the results of hot smoke tests, which were conducted in a real road tunnel. The tunnel is located within the expressway S69 in southern Poland between cities Żywiec and Zwardoń. Its common name is Laliki tunnel. It is a bidirectional non-urban tunnel. The length of the tunnel is 678 m and it is inclined by 4%. It is equipped with the longitudinal ventilation system. Two hot smoke tests have been carried out according to Australian Standard AS 4391-1999. Hot smoke tests corresponded to a Heat Release Rate (HRR equal to respectively 750 kW and 1500 kW. The fire source was located in the middle of the road lane imitating an initial phase of a car fire (respectively 150 m and 265 m from S portal. The temperature distribution was recorded during both tests using a set of fourteen thermocouples that were mounted at two stand poles located at the main axis of the tunnel on windward. The stand poles were placed at distances of 5 m and 10 m. The recorded data were applied to validate a numerical model, which was built and solved using Ansys Fluent. The calculated temperature distribution matched the measured values.

  14. Symmetric visualization of the femoral heads in reticuloendothelial bone marrow scanning in adults

    Energy Technology Data Exchange (ETDEWEB)

    Munz, D L; Hoer, G

    1983-03-01

    Two hundred and twenty seven consecutive patients of either sex aged 15-84 suffering from various benign and malignant disorders were studied by sup(99m)Tc-HSA-MM reticuloendothelial bone marrow scintigraphy. In all patients, symmetric findings concerning visualization or nonvisualization of the femoral heads could be seen. Femoral heads were clearly visualized in 48%, nonvisualized in 43%, and equivocally visualized in 9%. In patients with clearly visualized femoral heads, the bone marrow showed peripheral extension in 81%, whereas in patients with nonvisualized femoral heads, bone marrow extension was observed in only 42%. There was a correlation between the degree of bone marrow extension and the ability to visualize femoral heads. There was no obvious difference between males and females, nor patients with various diseases or treatments, amongst nor between different age groups. Two hypotheses are suggested to explain the correspondence between presence of bone marrow tissue in the femoral heads and peripheral extension of the bone marrow organ. Nonvisualization of the femoral heads alone is insufficient to establish the diagnosis of avascular necrosis.

  15. A biomechanical comparison of proximal femoral nails and locking proximal anatomic femoral plates in femoral fracture fixation A study on synthetic bones

    Directory of Open Access Journals (Sweden)

    Korhan Ozkan

    2015-01-01

    Conclusion: The proximal femoral intramedullary nail provides more stability and allows for earlier weight bearing than the locking plate when used for the treatment of unstable intertrochanteric fractures of the femur. Clinicians should be cautious for early weight bearing with locking plate for unstable intertrochanteric femur fractures.

  16. Investigations of Tunneling for Field Effect Transistors

    OpenAIRE

    Matheu, Peter

    2012-01-01

    Over 40 years of scaling dimensions for new and continuing product cycles has introduced new challenges for transistor design. As the end of the technology roadmap for semiconductors approaches, new device structures are being investigated as possible replacements for traditional metal-oxide-semiconductor field effect transistors (MOSFETs). Band-to-band tunneling (BTBT) in semiconductors, often viewed as an adverse effect of short channel lengths in MOSFETs, has been discussed as a promising ...

  17. Rock mass seismic imaging around the ONKALO tunnel, Olkiluoto 2007

    International Nuclear Information System (INIS)

    Cosma, C.; Cozma, M.; Balu, L.; Enescu, N.

    2008-11-01

    Posiva Oy prepares for disposal of spent nuclear fuel in bedrock focusing in Olkiluoto, Eurajoki. This is in accordance of the application filed in 1999, the Decision-in-Principle of the State Council in 2000, and ratification by the Parliament in 2001. Vibrometric Oy has performed a tunnel seismic survey in ONKALO access tunnel on a 100 m line in December 2007. Tunnel length (chainage) was 1720 - 1820 m (vertical depth 170 - 180 m). Measurement applied 120 source positions at 1 m spacing, and on the both ends at 4 m spacing. Electromechanical Vibsist-20 tool was used as the source. Hammer produced 15.36 s sweeps. Signal was recorded with 2-component geophone assemblies, installed in 400 mm long, 45 mm drillholes in the tunnel wall. Sweeps were recorded with Summit II seismograph and decoded to seismic traces. Also percussion drill rig, which is used in drilling the blasting holes in tunnel excavation, was tested from a 100-m distance as a seismic source. Signal is equally good as from actual seismic source, and may be applied later on for production. Obtained seismic results were processed with tomographic reconstruction of the first arrivals to P and S wave refraction tomograms, and to tomograms of Young's modulus and Shear Modulus. The obtained values correspond the typical levels known from Olkiluoto. There are indications of lower velocity near tunnel wall, but resolution is not adequate for further interpretation. Some variation of velocity is detected in the rock mass. Seismic data was also processed with normal reflection profile interpretation and migrated. As a result there was obtained reflection images to a 100-m distance from the tunnel. Several reflecting events were observed in the rock mass. Features making an angle of 30 deg or more with tunnel axis can be imaged from distances of tens of metres. Vertical fractures perpendicular to tunnel can be imaged only near the tunnel. Gently dipping features can be imaged below and above. Images are 2D, i

  18. Femoral bifurcation with ipsilateral tibia hemimelia: Early outcome of ...

    African Journals Online (AJOL)

    Hereby, we present a case report of a 2-year-old boy who first presented in our orthopedic clinic as a 12-day-old neonate, with a grossly deformed right lower limb from a combination of complete tibia hemimelia and ipsilateral femoral bifurcation. Excision of femoral exostosis, knee disarticulation and prosthetic fitting gives ...

  19. Breakthrough in current-in-plane tunneling measurement precision by application of multi-variable fitting algorithm.

    Science.gov (United States)

    Cagliani, Alberto; Østerberg, Frederik W; Hansen, Ole; Shiv, Lior; Nielsen, Peter F; Petersen, Dirch H

    2017-09-01

    We present a breakthrough in micro-four-point probe (M4PP) metrology to substantially improve precision of transmission line (transfer length) type measurements by application of advanced electrode position correction. In particular, we demonstrate this methodology for the M4PP current-in-plane tunneling (CIPT) technique. The CIPT method has been a crucial tool in the development of magnetic tunnel junction (MTJ) stacks suitable for magnetic random-access memories for more than a decade. On two MTJ stacks, the measurement precision of resistance-area product and tunneling magnetoresistance was improved by up to a factor of 3.5 and the measurement reproducibility by up to a factor of 17, thanks to our improved position correction technique.

  20. Macroscopic and microscopic findings in avascular necrosis of the femoral head.

    Science.gov (United States)

    Kamal, Diana; Alexandru, D O; Kamal, C K; Streba, C T; Grecu, D; Mogoantă, L

    2012-01-01

    The avascular necrosis of the femoral head is an illness induced by the cutoff of blood flow to the femoral head and it affects mostly young adults between the ages of 30 and 50 years, raising therapeutic and diagnostic issues. Many risk factors are incriminated in the development of avascular necrosis of the femoral head like: trauma, chronic alcohol consumption, smoking, administration of corticosteroid drugs, most of the cases are considered to be idiopathic. The main goal of our paper is to describe the macroscopic and microscopic variations of the bone structure, which occur in patients with avascular necrosis of the femoral head. The biological material needed for our study was obtained following hip arthroplasty surgery in 26 patients between the ages of 29 and 59 years, which previously were diagnosed with avascular necrosis of the femoral head and admitted in the Orthopedics Department of the Emergency County Hospital of Craiova (Romania) between 2010 and 2011. From a macroscopic point of view, we found well defined areas of necrosis, most of which were neatly demarcated of the adjacent viable tissue by hyperemic areas, loss of shape and contour of the femoral head and transformations of the articular cartilage above the area of necrosis. When examined under the microscope, we found vast areas of fibrosis, narrow bone trabeculae, obstructed blood vessels or blood vessels with clots inside, hypertrophic fat cells, bone sequestration but also small cells and pyknotic nuclei. The microscopic and macroscopic findings on the femoral head sections varied with the patients and the stage of the disease.

  1. Bone scintigraphy in idiopathic aseptic femoral head necrosis (IAFHN)

    Energy Technology Data Exchange (ETDEWEB)

    Dodig, D; Ugarkovic, B; Orlic, D

    1983-01-01

    Idiopathic aseptic femoral head necrosis (IAFHN) is a disease of unknown aetiology most commonly affecting adults, producing functional impairment of the hip joint and immobility. Characteristic macroscopic, microscopic and radiologic features include: (1) changes in joint cartilage, (2) subchondral necrotic area, (3) changes in fibrous tissue, and (4) osteosclerosis and vascular proliferation. The diagnosis is based on clinical and X-ray examinations. More recently scintigraphy has been used in diagnosing IAFHN. It is a very sensitive, but non-specific method. Nineteen patients aged 25-57 years were included in our study. Scintigrams were divided in four groups: (1) normal, (2) uniformly increased activity in the femoral head, (3) non-uniformly increased activity in the femoral head, and (4) a photon deficient area in the femoral head. A comparison of scintigraphy and radiological examination suggests that a photon deficient area corresponds with stage III of radiological classification, non-uniformly increased activity with stage II, and uniformly increased activity with stage I. These results indicate that scintigraphy can be used for staging of disease.

  2. Morphological size evaluation of the mid-substance insertion areas and the fan-like extension fibers in the femoral ACL footprint.

    Science.gov (United States)

    Suruga, Makoto; Horaguchi, Takashi; Iriuchishima, Takanori; Yahagi, Yoshiyuki; Iwama, Genki; Tokuhashi, Yasuaki; Aizawa, Shin

    2017-08-01

    The purpose of this study was to evaluate the detailed anatomy of the femoral anterior cruciate ligament (ACL) insertion site, with special attention given to the morphology of the mid-substance insertion areas and the fan-like extension fibers. Twenty-three non-paired human cadaver knees were used (7 Males, 16 Females, median age 83, range 69-96). All soft tissues around the knee were resected except the ligaments. The ACL was divided into antero-medial (AM) and postero-lateral (PL) bundles according to the difference in macroscopic tension patterns. The ACL was carefully dissected and two outlines were made of the periphery of each bundle insertion site: those which included and those which excluded the fan-like extension fibers. An accurate lateral view of the femoral condyle was photographed with a digital camera, and the images were downloaded to a personal computer. The area of each bundle, including and excluding the fan-like extension fibers, was measured with Image J software (National Institution of Health). The width and length of the mid-substance insertion sites were also evaluated using same image. The femoral ACL footprint was divided into four regions (mid-substance insertion sites of the AM and PL bundles, and fan-like extensions of the AM and PL bundles). The measured areas of the mid-substance insertion sites of the AM and PL bundles were 35.5 ± 12.5, and 32.4 ± 13.8 mm 2 , respectively. Whole width and length of the mid-substance insertion sites were 5.3 ± 1.4, and 15.5 ± 2.9 mm, respectively. The measured areas of the fan-like extensions of the AM and PL bundles were 27 ± 11.5, and 29.5 ± 12.4 mm 2 , respectively. The femoral ACL footprint was divided into quarters of approximately equal size (mid-substance insertion sites of the AM and PL bundles, and fan-like extensions of the AM and PL bundles). For clinical relevance, to perform highly reproducible anatomical ACL reconstruction, the presence of the fan-like extension

  3. Magnetic tunnel junctions with monolayer hexagonal boron nitride tunnel barriers

    Energy Technology Data Exchange (ETDEWEB)

    Piquemal-Banci, M.; Galceran, R.; Bouzehouane, K.; Anane, A.; Petroff, F.; Fert, A.; Dlubak, B.; Seneor, P. [Unité Mixte de Physique, CNRS, Thales, Univ. Paris-Sud, Université Paris-Saclay, Palaiseau 91767 (France); Caneva, S.; Martin, M.-B.; Weatherup, R. S.; Kidambi, P. R.; Robertson, J.; Hofmann, S. [Department of Engineering, University of Cambridge, Cambridge CB21PZ (United Kingdom); Xavier, S. [Thales Research and Technology, 1 avenue Augustin Fresnel, Palaiseau 91767 (France)

    2016-03-07

    We report on the integration of atomically thin 2D insulating hexagonal boron nitride (h-BN) tunnel barriers into Co/h-BN/Fe magnetic tunnel junctions (MTJs). The h-BN monolayer is directly grown by chemical vapor deposition on Fe. The Conductive Tip Atomic Force Microscopy (CT-AFM) measurements reveal the homogeneity of the tunnel behavior of our h-BN layers. As expected for tunneling, the resistance depends exponentially on the number of h-BN layers. The h-BN monolayer properties are also characterized through integration into complete MTJ devices. A Tunnel Magnetoresistance of up to 6% is observed for a MTJ based on a single atomically thin h-BN layer.

  4. [SURGICAL HIP DISLOCATION APPROACH FOR TREATMENT OF FEMORAL HEAD FRACTURE].

    Science.gov (United States)

    Tang, Yanfeng; Liu, Youwen; Zhu, Yingjie; Li, Jianming; Li, Wuyin; Li, Qiyi; Jia, Yudong

    2015-11-01

    To discuss the value of surgical hip dislocation approach in the treatment of femoral head fracture. A retrospectively analysis was made on the clinical data of 15 patients with femoral head fractures treated through surgical hip dislocation approach between January 2010 and February 2013. There were 11 men and 4 women with an average age of 30.8 years (range, 15-63 years). The causes included traffic accident injury in 9 cases, falling injury from height in 5 cases, and sports injury in 1 case. According to Pipkin typing, 2 cases were rated as type I, 7 cases as type II, 1 case as type III, and 5 cases as type IV. The interval of injury and operation was 2-10 days (mean, 4.1 days). Reduction was performed in 10 patients within 6 hours after injury, and then bone traction was given for 4-6 weeks except 5 patients who received reduction in the other hospital. Primary healing of incision was obtained in all patients after surgery without complications of dislocation and lower limbs deep venous thrombosis. The mean follow-up time was 29.9 months (range, 25-36 months). During follow-up, there was no infection, breakage of internal fixation, or nonunion of femoral greater trochanter fracture. In 3 patients having necrosis of the femoral head, 2 had no obvious symptoms [staging as IIa and IIb respectively according to Association Research Circulation Osseous (ARCO) staging system], and 1 (stage IIIb) had nonunion of the femoral neck fracture, who underwent total hip arthroplasty (THA). In 4 patients having myositis ossificans (2 cases of grade I, 1 case of grade II, and 1 case of grade III based on Brooker grading), no treatment was given in 3 cases and the focus was removed during THA in 1 case. According to the Thompson-Epstein scale at last follow-up, the results were excellent in 9 cases, good in 3 cases, fair in 1 case, and poor in 2 cases, and the excellent and good rate was 80%. Surgical hip dislocation approach can not only protect the residual vessels of the

  5. Interaction between groundwater and TBM (Tunnel Boring Machine) excavated tunnels

    OpenAIRE

    Font Capó, Jordi

    2012-01-01

    A number of problems, e.g. sudden inflows are encountered during tunneling under the piezometric level, especially when the excavation crosses high transmissivity areas. These inflows may drag materials when the tunnel crosses low competent layers, resulting in subsidence, chimney formation and collapses. Moreover, inflows can lead to a decrease in head level because of aquifer drainage. Tunnels can be drilled by a tunnel boring machine (TBM) to minimize inflows and groundwater impacts, restr...

  6. Computer-assisted three-dimensional correlation between the femoral neck-shaft angle and the optimal entry point for antegrade nailing.

    Science.gov (United States)

    Anastopoulos, George; Chissas, Dionisios; Dourountakis, Joseph; Ntagiopoulos, Panagiotis G; Magnisalis, Evaggelos; Asimakopoulos, Antonios; Xenakis, Theodore A

    2010-03-01

    Optimal entry point for antegrade femoral intramedullary nailing (IMN) remains controversial in the current medical literature. The definition of an ideal entry point for femoral IMN would implicate a tenseless introduction of the implant into the canal with anatomical alignment of the bone fragments. This study was undertaken in order to investigate possible existing relationships between the true 3D geometric parameters of the femur and the location of the optimum entry point. A sample population of 22 cadaveric femurs was used (mean age=51.09+/-14.82 years). Computed-tomography sections every 0.5mm for the entire length of femurs were produced. These sections were subsequently reconstructed to generate solid computer models of the external anatomy and medullary canal of each femur. Solid models of all femurs were subjected to a series of geometrical manipulations and computations using standard computer-aided-design tools. In the sagittal plane, the optimum entry point always lied a few millimeters behind the femoral neck axis (mean=3.5+/-1.5mm). In the coronal plane the optimum entry point lied at a location dependent on the femoral neck-shaft angle. Linear regression on the data showed that the optimal entry point is clearly correlated to the true 3D femoral neck-shaft angle (R(2)=0.7310) and the projected femoral neck-shaft angle (R(2)=0.6289). Anatomical parameters of the proximal femur, such as the varus-valgus angulation, are key factors in the determination of optimal entry point for nailing. The clinical relevance of the results is that in varus hips (neck-shaft angle shaft angle between 120 degrees and 130 degrees , the optimal entry point lies just medially to the trochanter tip (at the piriformis fossa) and the use of stiff implants is safe. In hips with neck-shaft angle over 130 degrees the anatomical axis of the canal is medially to the base of the neck, in a "restricted area". In these cases the entry point should be located at the insertion of the

  7. Seismic analysis of long tunnels: A review of simplified and unified methods

    Directory of Open Access Journals (Sweden)

    Haitao Yu

    2017-06-01

    Full Text Available Seismic analysis of long tunnels is important for safety evaluation of the tunnel structure during earthquakes. Simplified models of long tunnels are commonly adopted in seismic design by practitioners, in which the tunnel is usually assumed as a beam supported by the ground. These models can be conveniently used to obtain the overall response of the tunnel structure subjected to seismic loading. However, simplified methods are limited due to the assumptions that need to be made to reach the solution, e.g. shield tunnels are assembled with segments and bolts to form a lining ring and such structural details may not be included in the simplified model. In most cases, the design will require a numerical method that does not have the shortcomings of the analytical solutions, as it can consider the structural details, non-linear behavior, etc. Furthermore, long tunnels have significant length and pass through different strata. All of these would require large-scale seismic analysis of long tunnels with three-dimensional models, which is difficult due to the lack of available computing power. This paper introduces two types of methods for seismic analysis of long tunnels, namely simplified and unified methods. Several models, including the mass-spring-beam model, and the beam-spring model and its analytical solution are presented as examples of the simplified method. The unified method is based on a multiscale framework for long tunnels, with coarse and refined finite element meshes, or with the discrete element method and the finite difference method to compute the overall seismic response of the tunnel while including detailed dynamic response at positions of potential damage or of interest. A bridging scale term is introduced in the framework so that compatibility of dynamic behavior between the macro- and meso-scale subdomains is enforced. Examples are presented to demonstrate the applicability of the simplified and the unified methods.

  8. Multiple bony lesions other than femoral heads on 99mTc-MDP bone scan in patients with avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Choi, Yun Young; Yang, Seoung Oh; Moon, Dae Hyuk; Ryu, Jin Sook; Weon, Young Cheol; Shin, Myung Jin; Lee, Soo Ho; Lee, Hee Kyung; Chun, Hae Kyung

    1997-01-01

    To evaluate the clinical significance of the multiple increased uptake lesions other than in femoral heads as seen on whole body bone scan in patients with avascular necrosis of femoral heads. One hundred and seventy three patients with clinical diagnosis of avascular necrosis of the emoral head underwent a bone scan using Tc-99m MDP. Increased uptake lesions other than in femoral heads were evaluated, including frequency and common sites of in volvement, and correlated with clinical information and plain radiographic findings. Two hundred patients without AVN, who had undergone a bone scan, were included as a control group. Increased uptake lesions in extrafemoral head locations were found in 36 of 173 patients(20.8%;the location of 79 lesions was other than the femoral head, This result is statistically different from patients without avascular necrosis of femoral head(p<0.0001). The most common site of involvement was the knee joint area(62.5%). Other lesions were located in the mid-shafts of the long bones of the lower extremities, calcaneus, proximal humerus, etc., in order of decreasing frequency. Plain radiographs of 17 lesions were nonspecific, except for three lesions showing definite changes associated with avascular necrosis. The risk factors included alcoholism, the prolonged use of steroids, renal transplantation, herbal medication and working as a working as deep-sea diver. Most patients did not complain of pain, except for two with irreversible osteonecrotic changes as seen on plain radiograph. in patients with avascular necrosis of the femur, increased uptake lesions other than in the femoral head as seen on bone scan, may represent the early stage of osteonecrosis, which shows a characteristic appearance on bone scan. In order to aveid possible misdiagnoses of multiple extrafemoral lesions as bony metastasis or traumatic lesions, in patients with avascular necrosis of the femur these should be carefully evaluated

  9. 'Femoral head necrosis' in metabolic and hormonal osteopathies

    Energy Technology Data Exchange (ETDEWEB)

    Heuck, F.H.W.; Treugut, H.

    1984-07-01

    The pathogenesis of bone necrosis is discussed with special attention and with respect to metabolic, hormonal, and vascular factors. The influence of statics and dynamics of the hip joint bones for the development of aseptic necrosis are discussed. 45 patients with ''idiopathic femoral head necroses'' were observed, including 6 cases of renal osteopathy following renal transplantation and immune suppression therapy, 14 cases of long term corticoid therapy, and 11 cases of liver diseases of different genesis. The femoral head necrosis understood as complication of an osteopathy. In our patients there were 31 males and 14 females - which means higher involvement of males. Plain radiological findings and CT-findings of changes of the femoral heat structure in different stages of the disease are described. Early diagnosis of metabolic and hormonal osteopathies is demanded for a joint keeping therapy of the beginning femoral head necrosis. 90 refs.

  10. Mechanical Characterization of Femoral Cartilage Under Unicompartimental Osteoarthritis

    OpenAIRE

    Vidal-Lesso, A.; Ledesma-Orozco, E.; Daza-Benítez, L.; Lesso-Arroyo, R.

    2014-01-01

    The aim of this study was to determine the mechanical properties and thickness of articular cartilage in the unaffected femoral regions in cases of unicompartimental osteoarthritis on the knees. The specimens were tested using a 3mm plane-ended cylindrical indenter and a displacement of 0.5mm was applied at specific points in seven femoral knee cartilages with unicompartimental osteoarthritis. The thickness, stiffness, elastic modulus, shear modulus and bulk modulus were obtained. These prope...

  11. RITD – Wind tunnel testing

    Science.gov (United States)

    Haukka, Harri; Harri, Ari-Matti; Aleksashkin, Sergei; Koryanov, Valeri; Schmidt, Walter; Heilimo, Jyri; Finchenko, Valeri; Martynov, Maxim; Ponomarenko, Andrey; Kazakovtsev, Victor; Arruego, Ignazio

    2015-04-01

    An atmospheric re-entry and descent and landing system (EDLS) concept based on inflatable hypersonic decelerator techniques is highly promising for the Earth re-entry missions. We developed such EDLS for the Earth re-entry utilizing a concept that was originally developed for Mars. This EU-funded project is called RITD - Re-entry: Inflatable Technology Development - and it was to assess the bene¬fits of this technology when deploying small payloads from low Earth orbits to the surface of the Earth with modest costs. The principal goal was to assess and develope a preliminary EDLS design for the entire relevant range of aerodynamic regimes expected to be encountered in Earth's atmosphere during entry, descent and landing. The RITD entry and descent system utilizes an inflatable hypersonic decelerator. Development of such system requires a combination of wind tunnel tests and numerical simulations. This included wind tunnel tests both in transsonic and subsonic regimes. The principal aim of the wind tunnel tests was the determination of the RITD damping factors in the Earth atmosphere and recalculation of the results for the case of the vehicle descent in the Mars atmosphere. The RITD mock-up model used in the tests was in scale of 1:15 of the real-size vehicle as the dimensions were (midsection) diameter of 74.2 mm and length of 42 mm. For wind tunnel testing purposes the frontal part of the mock-up model body was manufactured by using a PolyJet 3D printing technology based on the light curing of liquid resin. The tail part of the mock-up model body was manufactured of M1 grade copper. The structure of the mock-up model placed th center of gravity in the same position as that of the real-size RITD. The wind tunnel test program included the defining of the damping factor at seven values of Mach numbers 0.85; 0.95; 1.10; 1.20; 1.25; 1.30 and 1.55 with the angle of attack ranging from 0 degree to 40 degrees with the step of 5 degrees. The damping characteristics of

  12. Femoral head allograft disinfection system using moderate heat

    International Nuclear Information System (INIS)

    Knaepler, H.; Von Garrel, T.

    1999-01-01

    The employment of a reliable thermal viral inactivation process, which minimally manipulates tissues, for surgically retrieved femoral head allografts addresses the increased concerns with virus transmissibility while minimizing the loss of biological properties. The newest European and German surgical bone banking guidelines have incorporated the use of independently validated then-nal viral inactivation methods in place of repeat serological testing of donor. Our investigations have shown that heat treatment at 80 degree C for a minimum of 10 minutes provides safe, good quality cancellous bone allografts and increases the cost-effectiveness and simplicity of managing a hospital frozen femoral head bone bank. Human femoral head centers were contaminated with different vegetative bacterial and viral suspensions. A core temperature of 80 degree C for 10 minutes was sufficient to fully inactivate 3 x 106 ml Staphylococcus aureus and Streptococcus faecalis, and >5 loglo steps of cytomeglia (herpes group), polio (enterovirus), and yellow fever (arbovirus) viruses. A one hour treatment in a water bath set at 80 degree sufficient to fully inactivate E. coli, proteus vulgaris, and Pseudomonas aerog. vegetative suspensions; 20 minutes was sufficient to fully inactivate the D antigen (rhesus factor) but had no effect on A or B antigens. Several biomechanical and biological properties of bone following a one hour treatment in a water bath set at 80 degree C were investigated. Employing compression and tension tests, 80 degree C treated human and porcine cancellous bone blocks showed reductions in properties ranging from 8-19% compared to untreated control groups. Osteointegration at 3 months following treatment of explanted and then reimplanted autograft rat diaphyseal segment was 15% less than untreated controls. Subsequently, a thermal disinfection system for femoral heads from living donors (Lobator Marburg Bone Bank System, Telos GmbH, Hungen, Germany) was developed. A

  13. Femoral intercondylar notch shape and dimensions in ACL-injured patients

    NARCIS (Netherlands)

    van Eck, Carola F.; Martins, Cesar A. Q.; Vyas, Shail M.; Celentano, Umberto; van Dijk, C. Niek; Fu, Freddie H.

    2010-01-01

    The femoral intercondylar notch has been an anatomic site of interest as it houses the anterior cruciate ligament (ACL). The objective of this study was to arthroscopically evaluate the femoral notch in patients with known ACL injury. This evaluation included establishing a classification for notch

  14. Modular femoral component for conversion of previous hip surgery in total hip arthroplasty.

    Science.gov (United States)

    Goldstein, Wayne M; Branson, Jill J

    2005-09-01

    The conversion of previous hip surgery to total hip arthroplasty creates a durable construct that is anatomically accurate. Most femoral components with either cemented or cementless design have a fixed tapered proximal shape. The proximal femoral anatomy is changed due to previous hip surgery for fixation of an intertrochanteric hip fracture, proximal femoral osteotomy, or a fibular allograft for avascular necrosis. The modular S-ROM (DePuy Orthopaedics Inc., Warsaw, Ind) hip stem accommodates these issues and independently prepares the proximal and distal portion of the femur. In preparation and implantation, the S-ROM hip stem creates less hoop stresses on potentially fragile stress risers from screws and thin bone. The S-ROM hip stem also prepares a previously distorted anatomy by milling through cortical bone that can occlude the femoral medullar canals and recreate proper femoral anteversion and reduces the risk of intraoperative or postoperative periprosthetic fracture due to the flexible titanium-slotted stem. The S-ROM femoral stem is recommended for challenging total hip reconstructions.

  15. Femoral bone strength in large theropod dinosaurs: A study by genus

    Science.gov (United States)

    Lee, Scott

    2015-03-01

    The locomotion of bipedal theropod dinosaurs is controlled by the strength of the femur to resist bending torques (caused by the foot striking the ground and the action of muscles on the femur). The section modulus at the narrowest part measures the ability of the femur to resist such torques. We present the results of our study of the femoral section moduli for six genus of large theropods: Tyrannosaurus, Nanotyrannus, Gorgosaurus, and Albertosaurus of the Late Cretaceous, Acrocanthosaurus of the Early Cretaceous, and Allosaurus of the Late Jurassic. These animals had femora of lengths between 65 and 134 cm. The corresponding section moduli varied between 23 and 570 cm3. Some species of Tyrannosaurus, Gorgosaurus, Allosaurus, and Albertosaurus had femora with lengths in the same 75 to 90 cm range. The section moduli of these animals are all in the same range, showing that the animals had the same abilities of locomotion. That is, Allosaurus of the Late Jurassic could locomote just as well as the Late Cretaceous Tyrannosaurus, Gorgosaurus, and Albertosaurus. There is no evidence that these later theropods had evolved to be any faster than similarly-sized theropods living about 80 million years earlier.

  16. Frequency driven inversion of tunnel magnetoimpedance and observation of positive tunnel magnetocapacitance in magnetic tunnel junctions

    International Nuclear Information System (INIS)

    Parui, Subir; Ribeiro, Mário; Atxabal, Ainhoa; Llopis, Roger; Bedoya-Pinto, Amilcar; Sun, Xiangnan; Casanova, Fèlix; Hueso, Luis E.

    2016-01-01

    The relevance for modern computation of non-volatile high-frequency memories makes ac-transport measurements of magnetic tunnel junctions (MTJs) crucial for exploring this regime. Here, we demonstrate a frequency-mediated effect in which the tunnel magnetoimpedance reverses its sign in a classical Co/Al 2 O 3 /NiFe MTJ, whereas we only observe a gradual decrease in the tunnel magnetophase. Such effects are explained by the capacitive coupling of a parallel resistor and capacitor in the equivalent circuit model of the MTJ. Furthermore, we report a positive tunnel magnetocapacitance effect, suggesting the presence of a spin-capacitance at the two ferromagnet/tunnel-barrier interfaces. Our results are important for understanding spin transport phenomena at the high frequency regime in which the spin-polarized charge accumulation due to spin-dependent penetration depth at the two interfaces plays a crucial role.

  17. Frequency driven inversion of tunnel magnetoimpedance and observation of positive tunnel magnetocapacitance in magnetic tunnel junctions

    Energy Technology Data Exchange (ETDEWEB)

    Parui, Subir, E-mail: s.parui@nanogune.eu, E-mail: l.hueso@nanogune.eu; Ribeiro, Mário; Atxabal, Ainhoa; Llopis, Roger [CIC nanoGUNE, 20018 Donostia-San Sebastian (Spain); Bedoya-Pinto, Amilcar [CIC nanoGUNE, 20018 Donostia-San Sebastian (Spain); Max Planck Institute of Microstructure Physics, D-06120 Halle (Germany); Sun, Xiangnan [CIC nanoGUNE, 20018 Donostia-San Sebastian (Spain); National Center for Nanoscience and Technology, 100190 Beijing (China); Casanova, Fèlix; Hueso, Luis E., E-mail: s.parui@nanogune.eu, E-mail: l.hueso@nanogune.eu [CIC nanoGUNE, 20018 Donostia-San Sebastian (Spain); IKERBASQUE, Basque Foundation for Science, 48011 Bilbao (Spain)

    2016-08-01

    The relevance for modern computation of non-volatile high-frequency memories makes ac-transport measurements of magnetic tunnel junctions (MTJs) crucial for exploring this regime. Here, we demonstrate a frequency-mediated effect in which the tunnel magnetoimpedance reverses its sign in a classical Co/Al{sub 2}O{sub 3}/NiFe MTJ, whereas we only observe a gradual decrease in the tunnel magnetophase. Such effects are explained by the capacitive coupling of a parallel resistor and capacitor in the equivalent circuit model of the MTJ. Furthermore, we report a positive tunnel magnetocapacitance effect, suggesting the presence of a spin-capacitance at the two ferromagnet/tunnel-barrier interfaces. Our results are important for understanding spin transport phenomena at the high frequency regime in which the spin-polarized charge accumulation due to spin-dependent penetration depth at the two interfaces plays a crucial role.

  18. Pigmented Villonodular Synovitis Causing Osteonecrosis of the Femoral Head: A Case Report

    Directory of Open Access Journals (Sweden)

    Tomohiro Mimura

    2013-01-01

    Full Text Available We report a case of a 27-year-old man with pigmented villonodular synovitis of the hip joint with coincident osteonecrosis of the femoral head. According to our review of the English-language literature, no detailed report of osteonecrosis of the femoral head complicated with pigmented villonodular synovitis has been published. Preoperative X-ray images showed joint narrowing and severe multiple bone erosions at the acetabulum and femoral neck. Magnetic resonance imaging revealed a low-intensity band attributable to osteonecrosis of the femoral head and massive diffuse pigmented villonodular synovitis lesions. Comparison of a three-dimensional computed tomographic image of this patient with an angiographic image of a normal individual demonstrated proximity of the pigmented villonodular synovitis-induced bone erosions to the medial and lateral femoral circumflex arteries and retinacular arteries, suggesting likely the compromise of the latter by the former. We propose that the massive pigmented villonodular synovitis may have contributed to the pathogenesis of osteonecrosis of the femoral head in this patient. We performed open synovectomy and total hip arthroplasty. No operative complications occurred, and no recurrence of the pigmented villonodular synovitis was detected for 3 years after the operation.

  19. Carpal Tunnel Syndrome

    Science.gov (United States)

    ... a passing cramp? It could be carpal tunnel syndrome. The carpal tunnel is a narrow passageway of ... three times more likely to have carpal tunnel syndrome than men. Early diagnosis and treatment are important ...

  20. Remote-controlled flexible pose measurement system and method for a moving target in wind tunnel

    Directory of Open Access Journals (Sweden)

    Wei LIU

    2018-01-01

    Full Text Available The measurement of position and attitude parameters for the isolated target from a high-speed aircraft is a great challenge in the field of wind tunnel simulation technology. This paper proposes a remote-controlled flexible pose measurement system in wind tunnel conditions for the separation of a target from an aircraft. The position and attitude parameters of a moving object are obtained by utilizing a single camera with a focal length and camera orientation that can be changed based on different measurement conditions. Using this proposed system and method, both the flexibility and efficiency of the pose measurement system can be enhanced in wind tunnel conditions to meet the measurement requirements of different objects and experiments, which is also useful for the development of an intelligent position and attitude measurement system. The position and the focal length of the camera also can be controlled remotely during measurements to enlarge both the vertical and horizontal measurement range of this system. Experiments are conducted in the laboratory to measure the position and attitude of moving objects with high flexibility and efficiency, and the measurement precision of the measurement system is also verified through experiments.

  1. Theory of superconducting tunneling without the tunneling Hamiltonian

    International Nuclear Information System (INIS)

    Arnold, G.B.

    1987-01-01

    When a tunneling barrier is nearly transparent, the standard tunneling (or transfer) Hamiltonian approximation fails. The author describes the theory which is necessary for calculating the tunneling current in these cases, and illustrate it by comparing theory and experiment on superconductor/insulator/superconductor (SIS) junctions have ultra-thin tunnel barriers. This theory accurately explains the subgap structure which appears in the dynamical resistance of such SIS junctions, including many observed details which no previous theory has reproduced. The expression for the current through an SIS junction with an ultrathin barrier is given by I(t) = Re{Sigma/sub n/ J/sub n/ (omega/sub o/)e/sup in omega/o/sup t/} where omega/sub o/ = 2eV/h is the Josephson frequency, V is the bias voltage, and the J/sub n/ are voltage dependent coefficients, one for each positive or negative integer, n, and n=0. The relative sign of the terms involving cos(n omega/sub o/t) and sin(n omega/sub o/t) agrees with experiment, in contrast to previous theories of Josephson tunneling

  2. Three-dimensional measurement of femoral neck anteversion and neck shaft angle.

    Science.gov (United States)

    Sangeux, Morgan; Pascoe, Jessica; Graham, H Kerr; Ramanauskas, Fiona; Cain, Tim

    2015-01-01

    We present a three-dimensional measurement technique for femoral neck anteversion and neck shaft angles which do not require alignment of the femoral and scanner axes. Two assessors performed the measurements on 11 patients (22 femurs). Repeatability between assessors was 2.7 degrees for femoral neck anteversion and 4.8 degrees for neck shaft angle. Measurements compared with an alternative single slice method were different by 2 degrees (3 degrees) in average. The method was repeatable and appropriate for clinical practice.

  3. Histopathology of femoral head donations: a retrospective review of 6161 cases.

    Science.gov (United States)

    Mackie, Katherine E; Zhou, Ziqiang; Robbins, Peter; Bulsara, Max; Zheng, Ming H

    2011-08-17

    Although total hip arthroplasty is one of the most common orthopaedic surgical procedures, it remains unclear whether histopathological examination of the excised femoral head adds to the quality of patient care. We propose that assessment of femoral heads resected during total hip arthroplasty and donated for allograft use may provide a profile of femoral head pathology that benefits total hip arthroplasty patients and bone donors. We retrospectively analyzed the histological findings reported for 6161 femoral heads donated for allograft use between 1993 and 2006. Specimens obtained during total hip arthroplasty and specimens donated at death were reviewed. Follow-up investigations that resulted from abnormal histopathological findings were also reviewed. The Western Australian Cancer Registry was used to determine whether patients with a suspected neoplasm were subsequently diagnosed with such a disease. A retrospective review of the histopathological findings was conducted to evaluate and reclassify all previous observations of abnormalities. One hundred and five femoral heads demonstrated abnormal or reactive histopathological features not reported prior to surgery and were rejected for allograft use. A reactive lymphocytic infiltrate, most likely due to osteoarthritis, was the most commonly identified feature (forty-five cases). Other features observed in twenty-seven cases were also most likely due to the presence of severe osteoarthritis. Ten femoral heads demonstrated plasmacytosis, which may have been related to osteoarthritis. Two patients were diagnosed with Paget's disease, and two, with rheumatoid arthritis. Nineteen patients had a suspected neoplasm. Of these nineteen, eight cases of non-Hodgkin's lymphoma or chronic lymphocytic leukemia and one case of myelodysplastic syndrome were confirmed on further investigation. One subsequently confirmed malignancy was detected per 770 femoral heads examined. Our findings indicate that, even with a detailed

  4. The Direct Anterior Approach Does Not Increase Return to Function Following Hemiarthroplasty for Femoral Neck Fracture.

    Science.gov (United States)

    Carlson, Victor R; Ong, Alvin C; Orozco, Fabio R; Lutz, Rex W; Duque, Andres F; Post, Zachary D

    2017-11-01

    The purpose of this study was to evaluate functional outcomes for hemiarthroplasty using a direct anterior approach or a direct lateral approach for femoral neck fracture. This retrospective review used data collected from a single institution between 2006 and 2016. Eighty-five and 75 consecutive patients who underwent hemiarthroplasty via a direct anterior approach and a direct lateral approach, respectively, met inclusion criteria. All patients with femoral neck fractures were treated by 1 of 2 fellowship-trained orthopedic surgeons using the direct anterior approach or the direct lateral approach to hemiarthroplasty. Disposition, ambulation, and other perioperative surgical outcomes were compared between the cohorts. Compared with the direct lateral cohort, the direct anterior cohort had a shorter mean operative time (2.4 minutes, P<.01), a shorter mean length of hospital stay (2.7 days, P<.01), and a smaller mean decrease in hemoglobin postoperatively (0.7 g/dL, P<.01). No significant difference was observed between the cohorts for postoperative disposition, the number of feet ambulated on the second postoperative day, or the prevalence of ambulatory decline at 4- to 6-week and 4- to 6-month follow-up visits. Compared with the direct lateral approach, the direct anterior approach may benefit patients by small, but statistically significant, improvements in blood loss, surgical time, and length of hospital stay after hemiarthroplasty. However, the direct anterior approach does not appear to decrease the likelihood of transfer to a skilled nursing facility postoperatively or accelerate return to preoperative function. [Orthopedics. 2017; 40(6):e1055-e1061.]. Copyright 2017, SLACK Incorporated.

  5. Deformation measurements at the vehicle tunnel overpass using a hydrostatic level system

    International Nuclear Information System (INIS)

    Friedsam, H.; Penicka, J.; Error, J.

    1996-04-01

    Long-term storage ring and experiment hall floor settlements are being monitored on a regular bases in six-month intervals utilizing common geometric leveling techniques. One area of concern requiring special attention in terms of settlements is the vehicle tunnel that undercuts the experiment hall an storage ring at the south side of the APS. Five user beamlines crossing over the vehicle tunnel could be affected by deformations in this area. Assuming the most severe temperature fluctuations would occur during the winter time, a monitoring system was installed at the beginning of 1996. The length of the experiment was dictated by the installation schedule of the user enclosures at the overpass

  6. Methodology of using CFD-based risk assessment in road tunnels

    Directory of Open Access Journals (Sweden)

    Vidmar Peter

    2007-01-01

    Full Text Available The definition of the deterministic approach in the safety analyses comes from the need to understand the conditions that come out during the fire accident in a road tunnel. The key factor of the tunnel operations during the fire is the ventilation, which during the initial fazes of the fire, impact strongly on the evacuation of people and latter on the access of the intervention units in the tunnel. The paper presents the use of the computational fluid dynamics model in the tunnel safety assessment process. The model is validated by comparing data with experimental and quantifying the differences. The set-up of the initial and boundary conditions and the requirement for grid density found during the validation tests is used to prepare three kind of fire scenarios 20 MW, 50 MW, and 100 MW, with different ventilation conditions; natural, semi transverse, full transverse, and longitudinal ventilation. The observed variables, soot density and temperature, are presented in minutes time steps trough the entire tunnel length. Comparing the obtained data in a table, allows the analyses of the ventilation conditions for different heat releases from fires. The second step is to add additional criteria of human behaviour inside the tunnel (evacuation and human resistance to the elevated gas concentrations and temperature. What comes out is a fully deterministic risk matrix that is based on the calculated data where the risk is ranged on five levels, from the lowest to a very danger level. The deterministic risk matrix represents the alternative to a probabilistic safety assessment methodology, where the fire risk is represented in detail as well as the computational fluid dynamics model results are physically correct. .

  7. Forward prediction of tunnel face by use of equi-traveltime planes; Tosojimen no riyo ni yoru tunnel kiriha zenpo tansa

    Energy Technology Data Exchange (ETDEWEB)

    Ashida, Y [Kyoto University, Kyoto (Japan). Faculty of Engineering; Hirano, T [Nishimatsu Construction Co. Ltd., Tokyo (Japan)

    1996-05-01

    The result is reported herein of a depth transform algorithm application utilizing equi-traveltime planes in reflection seismic exploration for the purpose of knowing the structure configuration in front of the tunnel face in a tunnel excavation process. A vibration producing hole was provided 0.5m above the ground surface while a vibration receiving hole was provided at 1.5m above the ground surface, and the excavated lengths were 1.5m and 0.5m, respectively. There were 24 recording channels, from which inline offset records were taken. The on-site records were subjected to 100-1000Hz band pass filtering. The elastic wave propagation rate in the rock used for depth conversion was set at 400m/s in consideration of the distance and direct wave travel time from the vibration source to the vibration receiving point. As the result of study, weak layers were found in the neighborhood of 230-240m, 260-270m, and 280-290m. This method requires less core memory for calculation and completes calculation in a shorter period of time, which enables a conclusion that it will be effective in grasping the 3-dimensional structure in front of the tunnel face in the working scene. 4 refs., 7 figs.

  8. Delayed appearance of hypaesthesia and paralysis after femoral nerve block

    Directory of Open Access Journals (Sweden)

    Stefan Landgraeber

    2012-03-01

    Full Text Available We report on a female patient who underwent an arthroscopy of the right knee and was given a continuous femoral nerve block catheter. The postoperative course was initially unremarkable, but when postoperative mobilisation was commenced, 18 hours after removal of the catheter, the patient noticed paralysis and hypaesthesia. Examination confirmed the diagnosis of femoral nerve dysfunction. Colour duplex sonography of the femoral artery and computed tomography of the lumbar spine and pelvis yielded no pathological findings. Overnight the neurological deficits decreased without therapy and were finally no longer detectable. We speculate that during the administration of the local anaesthetic a depot formed, localised in the medial femoral intermuscular septa, which was leaked after first mobilisation. To our knowledge no similar case has been published up to now. We conclude that patients who are treated with a nerve block should be informed and physician should be aware that delayed neurological deficits are possible.

  9. Delayed appearance of hypaesthesia and paralysis after femoral nerve block

    Science.gov (United States)

    Landgraeber, Stefan; Albrecht, Thomas; Reischuck, Ulrich; von Knoch, Marius

    2012-01-01

    We report on a female patient who underwent an arthroscopy of the right knee and was given a continuous femoral nerve block catheter. The postoperative course was initially unremarkable, but when postoperative mobilisation was commenced, 18 hours after removal of the catheter, the patient noticed paralysis and hypaesthesia. Examination confirmed the diagnosis of femoral nerve dysfunction. Colour duplex sonography of the femoral artery and computed tomography of the lumbar spine and pelvis yielded no pathological findings. Overnight the neurological deficits decreased without therapy and were finally no longer detectable. We speculate that during the administration of the local anaesthetic a depot formed, localised in the medial femoral intermuscular septa, which was leaked after first mobilisation. To our knowledge no similar case has been published up to now. We conclude that patients who are treated with a nerve block should be informed and physician should be aware that delayed neurological deficits are possible. PMID:22577509

  10. Temperature dependence of the superconducting proximity effect quantified by scanning tunneling spectroscopy

    Directory of Open Access Journals (Sweden)

    A. Stępniak

    2015-01-01

    Full Text Available Here, we present the first systematic study on the temperature dependence of the extension of the superconducting proximity effect in a 1–2 atomic layer thin metallic film, surrounding a superconducting Pb island. Scanning tunneling microscopy/spectroscopy (STM/STS measurements reveal the spatial variation of the local density of state on the film from 0.38 up to 1.8 K. In this temperature range the superconductivity of the island is almost unaffected and shows a constant gap of a 1.20 ± 0.03 meV. Using a superconducting Nb-tip a constant value of the proximity length of 17 ± 3 nm at 0.38 and 1.8 K is found. In contrast, experiments with a normal conductive W-tip indicate an apparent decrease of the proximity length with increasing temperature. This result is ascribed to the thermal broadening of the occupation of states of the tip, and it does not reflect an intrinsic temperature dependence of the proximity length. Our tunneling spectroscopy experiments shed fresh light on the fundamental issue of the temperature dependence of the proximity effect for atomic monolayers, where the intrinsic temperature dependence of the proximity effect is comparably weak.

  11. Comparison of classical reaction paths and tunneling paths studied with the semiclassical instanton theory.

    Science.gov (United States)

    Meisner, Jan; Markmeyer, Max N; Bohner, Matthias U; Kästner, Johannes

    2017-08-30

    Atom tunneling in the hydrogen atom transfer reaction of the 2,4,6-tri-tert-butylphenyl radical to 3,5-di-tert-butylneophyl, which has a short but strongly curved reaction path, was investigated using instanton theory. We found the tunneling path to deviate qualitatively from the classical intrinsic reaction coordinate, the steepest-descent path in mass-weighted Cartesian coordinates. To perform that comparison, we implemented a new variant of the predictor-corrector algorithm for the calculation of the intrinsic reaction coordinate. We used the reaction force analysis method as a means to decompose the reaction barrier into structural and electronic components. Due to the narrow energy barrier, atom tunneling is important in the abovementioned reaction, even above room temperature. Our calculated rate constants between 350 K and 100 K agree well with experimental values. We found a H/D kinetic isotope effect of almost 10 6 at 100 K. Tunneling dominates the protium transfer below 400 K and the deuterium transfer below 300 K. We compared the lengths of the tunneling path and the classical path for the hydrogen atom transfer in the reaction HCl + Cl and quantified the corner cutting in this reaction. At low temperature, the tunneling path is about 40% shorter than the classical path.

  12. Stress fracture of the femoral neck in a child (stress fracture)

    International Nuclear Information System (INIS)

    Coldwell, D.; Gross, G.W.; Boal, D.K.

    1984-01-01

    Femoral neck stress fracture is extremely rare in childhood. We report a case of femoral neck stress fracture in an 11-year-old girl. Differentials diagnosis and a brief review of the literature follow. (orig.)

  13. Effect of quantum tunneling on spin Hall magnetoresistance.

    Science.gov (United States)

    Ok, Seulgi; Chen, Wei; Sigrist, Manfred; Manske, Dirk

    2017-02-22

    We present a formalism that simultaneously incorporates the effect of quantum tunneling and spin diffusion on the spin Hall magnetoresistance observed in normal metal/ferromagnetic insulator bilayers (such as Pt/Y 3 Fe 5 O 12 ) and normal metal/ferromagnetic metal bilayers (such as Pt/Co), in which the angle of magnetization influences the magnetoresistance of the normal metal. In the normal metal side the spin diffusion is known to affect the landscape of the spin accumulation caused by spin Hall effect and subsequently the magnetoresistance, while on the ferromagnet side the quantum tunneling effect is detrimental to the interface spin current which also affects the spin accumulation. The influence of generic material properties such as spin diffusion length, layer thickness, interface coupling, and insulating gap can be quantified in a unified manner, and experiments that reveal the quantum feature of the magnetoresistance are suggested.

  14. Aberrant femoral torsion presenting with frog-leg squatting mimicking gluteal muscle contracture.

    Science.gov (United States)

    Chiang, Chia-Ling; Tsai, Meng-Yuan; Chang, Wei-Ning; Chen, Clement Kuen-Huang

    2012-04-01

    Patients with frog-leg squatting have restricted internal rotation and adduction of the affected hips during sitting or squatting. In the surgical literature, the cause generally has been presumed to arise from and be pathognomonic for gluteal muscle contracture. However, we have encountered patients with frog-leg squatting but without gluteal muscle contracture. We therefore raised the following questions: What are the imaging features of patients with frog-leg squatting? Do conditions other than gluteal muscle contracture manifest frog-leg squatting? We retrospectively reviewed the MR images of 67 patients presenting with frog-leg squatting from April 1998 to July 2010. There were four females and 63 males; their mean age was 22.2 years (range, 4-50 years). During MRI readout, we observed aberrant axes of some femoral necks and obtained additional CT to measure femoral torsion angles in 59 of the 67 patients. MR images of 27 (40%) patients had signs of gluteal muscle contracture. Twenty-two (33%) patients (40 femora) had aberrant femoral torsion, including diminished anteversion (range, 6°-0°; average, 3.9°) in 11 femora of eight patients and femoral retroversion (range, muscle contracture or aberrant femoral torsion. The observation of aberrant femoral torsion was not anticipated before imaging studies. In addition to gluteal muscle contracture, aberrant femoral torsion can be a cause of frog-leg squatting. Level II, diagnostic study. See the guidelines for Authors for a complete description of levels of evidence.

  15. Does increased femoral antetorsion predispose to cartilage lesions of the patellofemoral joint?

    Science.gov (United States)

    Oppermann, Johannes; Bredow, Jan; Wissusek, Boris; Spies, Christian Karl; Boese, Christoph Kolja; Chang, Shi-Min; Eysel, Peer; Dargel, Jens

    2017-09-01

    The purpose of this study was to investigate whether there was a relationship between femoral neck antetorsion and the presence and pattern of osteoarthritis of the patellofemoral joint. It was hypothesized that an increased femoral neck antetorsion (1) correlates with osteoarthritic changes of the lateral facet of the patellofemoral joint and (2) correlates with an increased lateral trochlear height and a decreased sulcus angle. Seventy-eight formalin-embedded cadaveric lower extremities from thirty-nine subjects with a median age of 74 years (range 60-88) were used. Surrounding soft tissues of the lower limb were removed. The femoral neck antetorsion was measured and referenced to the transepicondylar axis and the posterior condylar line. The height of the medial and lateral facet of the trochlea and the sulcus angle was measured. The location and the degree of patellofemoral cartilage degeneration were recorded. A Pearson's correlation analysis was performed to correlate the femoral neck antetorsion with the measured knee parameters. No significant correlation could be found between the femoral antetorsion and cartilage degeneration of the lateral patellofemoral joint (n.s.), the height of the lateral trochlea (n.s.) and the sulcus angle (n.s.). This study could not document that the femoral neck antetorsion and subsequent internal rotation of the distal femur correlated with the degree of degeneration of the lateral facet of the patellofemoral joint. Clinically, femoral internal rotation may play a minor role in the development of lateral patellofemoral joint degeneration.

  16. Tunneling works. Tunnel koji

    Energy Technology Data Exchange (ETDEWEB)

    Higo, M [Hazam Gumi, Ltd., Tokyo (Japan)

    1991-10-25

    A mountain tunneling method for rock-beds used to be applied mainly to construction works in the mountains under few restrictions by environmental problems. However, construction works near residential sreas have been increasing. There are such enviromental problems due to tunneling works as vibration, noise, lowering of ground-water level, and influences on other structures. This report mainly describes the measurement examples of vibration and noise accompanied with blasting and the effects of the measures to lessen such influences. When the tunneling works for the railroad was carried out on the natural ground mainly composed of basalt, vibration of the test blasting was measured at three stations with piezoelectric accelerometers. Then, ordinary blasting, mutistage blasting, and ABM blasting methods were used properly besed on the above results, and only a few complaints were made. In the different works, normal noise and low-frequency sound were mesured at 22 stations around the pit mouth. As countermeasures for noise, sound-proof sheets, walls, and single and double doors were installed and foundto be effective. 1 ref., 6 figs., 1 tab.

  17. Isolated femoral hypoplasia: an intrauterine differential diagnosis to campomelia

    Energy Technology Data Exchange (ETDEWEB)

    Koerber, Friederike; Benz-Bohm, Gabriele [University of Cologne, Department of Paediatric Radiology, Cologne (Germany); Schoenau, Eckard [University of Cologne, Department of Paediatrics, Cologne (Germany); Horwitz, A.Eldad [Klinikum Krefeld, Department of Paediatric Radiology, Krefeld (Germany)

    2005-06-01

    The isolated form of femoral bowing is an important differential diagnosis of campomelia. Therefore, knowledge of isolated anomalies is fundamental for prenatal diagnosis, especially for the differential diagnosis from severe syndromes. Four cases are presented to discuss the differential diagnosis of femoral bowing including a review of the literature. We report four newborn babies with unilateral bowing and shortening of the femur. Three had no further anomaly; one child had additional abnormalities due to coumarin embryopathy. The radiological findings were shortened femora with bowing and varus deformity and cortical thickening on the concave side. All other parts showed normal bone structure. The aetiology of femoral bowing is unknown. Early damage of the cartilaginous model followed by remodelling with thickening on the concave side of the bone similar to the healing of malaligned fractures is suspected. The isolated form of femoral bowing without any other anomalies has to be differentiated from complex and more often severe congenital syndromes such as campomelia. Postpartum radiological examination should be reduced to a single exposure of the affected limb and follow-up should be done by clinical examination. (orig.)

  18. Transfer of obturator nerve for femoral nerve injury: an experiment study in rats.

    Science.gov (United States)

    Meng, Depeng; Zhou, Jun; Lin, Yaofa; Xie, Zheng; Chen, Huihao; Yu, Ronghua; Lin, Haodong; Hou, Chunlin

    2018-07-01

    Quadriceps palsy is mainly caused by proximal lesions in the femoral nerve. The obturator nerve has been previously used to repair the femoral nerve, although only a few reports have described the procedure, and the outcomes have varied. In the present study, we aimed to confirm the feasibility and effectiveness of this treatment in a rodent model using the randomized control method. Sixty Sprague-Dawley rats were randomized into two groups: the experimental group, wherein rats underwent femoral neurectomy and obturator nerve transfer to the femoral nerve motor branch; and the control group, wherein rats underwent femoral neurectomy without nerve transfer. Functional outcomes were measured using the BBB score, muscle mass, and histological assessment. At 12 and 16 weeks postoperatively, the rats in the experimental group exhibited recovery to a stronger stretch force of the knee and higher BBB score, as compared to the control group (p nerve with myelinated and unmyelinated fibers was observed in the experimental group. No significant differences were observed between groups at 8 weeks postoperatively (p > 0.05). Obturator nerve transfer for repairing femoral nerve injury was feasible and effective in a rat model, and can hence be considered as an option for the treatment of femoral nerve injury.

  19. Outcomes of trochanteric femoral fractures treated with proximal femoral nail: an analysis of 100 consecutive cases.

    Science.gov (United States)

    Korkmaz, Mehmet Fatih; Erdem, Mehmet Nuri; Disli, Zeliha; Selcuk, Engin Burak; Karakaplan, Mustafa; Gogus, Abdullah

    2014-01-01

    In this study, we aimed to report the results of a retrospective study carried out at our institute regarding cases of patients who had suffered proximal femoral fractures between January 2002 and February 2007, and who were treated with a proximal femoral nail. One hundred consecutive cases were included in the study. A case documentation form was used to obtain intraoperative data including age, sex, mechanism of injury, type of fracture according to Association for Osteosynthesis/Association for the Study of Internal Fixation (AO/ASIF) classification and the American Society of Anesthesiologists' (ASA) physical status classification (ASA grade). Clinical and radiographic examinations were performed at the time of admission and at the 6th week; subsequent visits were organized on the 3rd month, 6th month, and 12th month, and in patients with longer follow-up and annually postoperatively. The Harris score of hip function was used, and any change in the position of the implants and the progress of the fracture union, which was determined radiologically, was noted. The mean age of the patients was 77.66 years (range: 37-98 years), and the sex distribution was 32 males and 68 females. Seventy-three fractures were reduced by closed means, whereas 27 needed limited open reduction. The mean follow-up time for the study group was 31.3 months (range: 12-75 months). Postoperative radiographs showed a near-anatomical fracture reduction in 78% of patients. The Harris hip score was negatively correlated with the ASA score and patient age. No cases of implant failure were observed. Three patients died before discharge (one due to pulmonary embolism, two due to cardiac arrest), and five patients died due to unrelated medical conditions within the first 3 months of the follow-up. Our study showed that proximal femoral nail is a reliable fixation with good fracture union, and it is not associated with major complications in any type of trochanteric femoral fracture.

  20. Multiple bony lesions other than femoral heads on {sup 99m}Tc-MDP bone scan in patients with avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yun Young; Yang, Seoung Oh; Moon, Dae Hyuk; Ryu, Jin Sook; Weon, Young Cheol; Shin, Myung Jin; Lee, Soo Ho; Lee, Hee Kyung [Asan Medical Center, Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of); Chun, Hae Kyung [St. Francisco Hospital, Seoul (Korea, Republic of)

    1997-03-01

    To evaluate the clinical significance of the multiple increased uptake lesions other than in femoral heads as seen on whole body bone scan in patients with avascular necrosis of femoral heads. One hundred and seventy three patients with clinical diagnosis of avascular necrosis of the emoral head underwent a bone scan using Tc-99m MDP. Increased uptake lesions other than in femoral heads were evaluated, including frequency and common sites of in volvement, and correlated with clinical information and plain radiographic findings. Two hundred patients without AVN, who had undergone a bone scan, were included as a control group. Increased uptake lesions in extrafemoral head locations were found in 36 of 173 patients(20.8%); the location of 79 lesions was other than the femoral head. This result is statistically different from patients without avascular necrosis of femoral head(p<0.0001). The most common site of involvement was the knee joint area(62.5%). Other lesions were located in the mid-shafts of the long bones of the lower extremities, calcaneus, proximal humerus, etc., in order of decreasing frequency. Plain radiographs of 17 lesions were nonspecific, except for three lesions showing definite changes associated with avascular necrosis. The risk factors included alcoholism, the prolonged use of steroids, renal transplantation, herbal medication and working as a working as deep-sea diver. Most patients did not complain of pain, except for two with irreversible osteonecrotic changes as seen on plain radiograph. in patients with avascular necrosis of the femur, increased uptake lesions other than in the femoral head as seen on bone scan, may represent the early stage of osteonecrosis, which shows a characteristic appearance on bone scan. In order to aveid possible misdiagnoses of multiple extrafemoral lesions as bony metastasis or traumatic lesions, in patients with avascular necrosis of the femur these should be carefully evaluated.

  1. Traumatic subchondral fracture of the femoral head in a healed trochanteric fracture.

    Science.gov (United States)

    Lee, Sang Yang; Niikura, Takahiro; Iwakura, Takashi; Kurosaka, Masahiro

    2014-07-11

    An 82-year-old woman sustained a trochanteric fracture of the left femur after a fall. Fracture fixation was performed using proximal femoral nail antirotation (PFNA) II, and she was able to walk with a T-cane after 3 months. Eleven months following the operation, the patient presented with left hip pain after a fall. Radiographs showed a subchondral collapse of the femoral head located above the blade tip. The authors removed the PFNA-II and subsequently performed cemented bipolar hemiarthroplasty. Histological evaluation of the femoral head showed osteoporosis with no evidence of osteonecrosis. Repair tissue, granulation tissue and callus formation were seen at the collapsed subchondral area. Based on these findings, a traumatic subchondral fracture of the femoral head in a healed trochanteric fracture was diagnosed. A traumatic subchondral fracture of the femoral head may need to be considered as a possible diagnosis after internal fixation of the trochanteric fracture. 2014 BMJ Publishing Group Ltd.

  2. High Folic Acid Intake during Pregnancy Lowers Body Weight and Reduces Femoral Area and Strength in Female Rat Offspring

    Directory of Open Access Journals (Sweden)

    Pedro S. P. Huot

    2013-01-01

    Full Text Available Rats fed gestational diets high in multivitamin or folate produce offspring of altered phenotypes. We hypothesized that female rat offspring born to dams fed a gestational diet high in folic acid (HFol have compromised bone health and that feeding the offspring the same HFol diet attenuates these effects. Pregnant rats were fed diets with either recommended folic acid (RFol or 10-fold higher folic acid (HFol amounts. Female offspring were weaned to either the RFol or HFol diet for 17 weeks. HFol maternal diet resulted in lower offspring body weights (6%, P=0.03 and, after adjusting for body weight and femoral length, smaller femoral area (2%, P=0.03, compared to control diet. After adjustments, HFol pup diet resulted in lower mineral content (7%, P=0.01 and density (4%, P=0.002 of lumbar vertebra 4 without differences in strength. An interaction between folate content of the dam and pup diets revealed that a mismatch resulted in lower femoral peak load strength (P=0.01 and stiffness (P=0.002. However, the match in folate content failed to prevent lower weight gain. In conclusion, HFol diets fed to rat dams and their offspring affect area and strength of femurs and mineral quantity but not strength of lumbar vertebrae in the offspring.

  3. Ipsilateral femoral shaft and vertical patella fracture: a case report

    Science.gov (United States)

    Ozkan, Korhan; Eceviz, Engin; Sahin, Adem; Ugutmen, Ender

    2009-01-01

    Introduction A femoral shaft fracture with an ipsilateral patella fracture has been, to our knowledge, given only cursory attention in English-speaking literature. Case presentation A 15 year old male patient had hitten by a car to his motorcycle came to emergency room and he had been operated for his femoral shaft freacture and vertical patellar fracture which was iniatally missed. Conclusion To us it is vital to obtain CT scan of the patient’s knee if there is an ipsilateral femoral fracture with an ipsilateral knee effusion and a punction which reveals hematoma even in the absence of a fracture line seen in AP and lateral projections. PMID:19829933

  4. Morphometric findings in avascular necrosis of the femoral head.

    Science.gov (United States)

    Kamal, Diana; Trăistaru, Rodica; Alexandru, D O; Kamal, C K; Pirici, D; Pop, O T; Mălăescu, D Gh

    2012-01-01

    Avascular necrosis of the femoral head is an illness with a controversial etiology, the trigger event being the suppression of blood flow to the femoral head. The disease affects mostly young adults within their third and fifth decade, the majority of the patients being men. The main risk factors are trauma, chronic alcohol consumption, smoking, corticotherapy. The main goal of our study is to describe the morphometric changes found in the bone tissue of patients diagnosed with avascular necrosis of the femoral head, with different risk factors, by comparing the area of bone trabeculae inside the area of necrosis with that from the adjacent viable tissue. The morphometric study used biological material from 16 patients with ages between 29 and 57 years, who underwent surgery for avascular necrosis of the femoral head. They were admitted in the Orthopedics Department at the Emergency County Hospital in Craiova between 2010 and 2011 and were split into four groups. Group I presented trauma as the main risk factor, Group II had corticotherapy as the defining risk factor, Group III presented chronic alcohol consumption and Group IV was represented by the patients who smoked and exhibited chronic alcohol consumption. There was not a significant statistical difference between the areas of bone trabeculae of the four groups when we compared viable bone tissue to the necrotized one. Knowing the risk factors of the avascular necrosis of the femoral head is critical to the management of the disease, because diagnosing it in an early stage is a necessity for obtaining a good result for conservative treatment.

  5. Tunneling junction as an open system. Normal tunneling

    International Nuclear Information System (INIS)

    Ono, Y.

    1978-01-01

    The method of the tunneling Hamiltonian is reformulated in the case of normal tunneling by introducing two independent particle baths. Due to the baths, it becomes possible to realize a final stationary state where the electron numbers of the two electrodes in the tunneling system are maintained constant and where there exists a stationary current. The effect of the bath-system couplings on the current-voltage characteristics of the junction is discussed in relation to the usual expression of the current as a function of voltage. (Auth.)

  6. Incidence and predictors of post-catheterization femoral artery pseudoaneurysms

    OpenAIRE

    Kassem, Hussein Heshmat; Elmahdy, Mahmoud Farouk; Ewis, Essam Baligh; Mahdy, Soilman Ghareeb

    2013-01-01

    Background: Femoral artery pseudoaneurysm (FAP) is a troublesome complication after transfemoral catheter procedures. The incidence and predictors of FAP as a separate entity have not been extensively studied. Aim: Detect prospectively the incidence and predictors of post catheterization FAP. Methods: From June 2009 till June 2011, we prospectively included all patients who underwent catheterization from the femoral approach. Duplex ultrasound was performed in cases with clinical suspic...

  7. [Treatment of femoral neck fracture--preference to internal fixation].

    Science.gov (United States)

    Minato, Izumi

    2011-03-01

    In the guidelines for the treatment of femoral neck fracture, prosthetic replacement is recommended in displaced one and internal fixation is in undisplaced one. However, in the long view, survived femoral head after internal fixation can be superior to prosthesis which will deteriorate as time goes by. Surgical method should be considered not only by type of fracture but general status of the patient.

  8. Subchondral bone density distribution in the human femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Wright, David A.; Meguid, Michael; Lubovsky, Omri; Whyne, Cari M. [Sunnybrook Research Institute, Orthopaedic Biomechanics Laboratory, Toronto, Ontario (Canada)

    2012-06-15

    This study aims to quantitatively characterize the distribution of subchondral bone density across the human femoral head using a computed tomography derived measurement of bone density and a common reference coordinate system. Femoral head surfaces were created bilaterally for 30 patients (14 males, 16 females, mean age 67.2 years) through semi-automatic segmentation of reconstructed CT data and used to map bone density, by shrinking them into the subchondral bone and averaging the greyscale values (linearly related to bone density) within 5 mm of the articular surface. Density maps were then oriented with the center of the head at the origin, the femoral mechanical axis (FMA) aligned with the vertical, and the posterior condylar axis (PCA) aligned with the horizontal. Twelve regions were created by dividing the density maps into three concentric rings at increments of 30 from the horizontal, then splitting into four quadrants along the anterior-posterior and medial-lateral axes. Mean values for each region were compared using repeated measures ANOVA and a Bonferroni post hoc test, and side-to-side correlations were analyzed using a Pearson's correlation. The regions representing the medial side of the femoral head's superior portion were found to have significantly higher densities compared to other regions (p < 0.05). Significant side-to-side correlations were found for all regions (r {sup 2} = 0.81 to r {sup 2} = 0.16), with strong correlations for the highest density regions. Side-to-side differences in measured bone density were seen for two regions in the anterio-lateral portion of the femoral head (p < 0.05). The high correlation found between the left and right sides indicates that this tool may be useful for understanding 'normal' density patterns in hips affected by unilateral pathologies such as avascular necrosis, fracture, developmental dysplasia of the hip, Perthes disease, and slipped capital femoral head epiphysis. (orig.)

  9. Avascular necrosis of femoral head: findings of contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Shin, Yong Moon; Kang, Heung Sik; Kim, Chu Wan; Kim, Hee Joong; Kim, Young Min

    1995-01-01

    To evaluate the findings and the role of contrast enhanced magnetic resonance imaging in avascular necrosis of femoral head. Sixteen patients with avascular necorsis of femoral head were examined with MRI. T1-weighted and T2-weighted image and contrast-enhanced T1-weighted images were obtained. Enhancing characteristics of the necrotic area and synovium were determined. Also a change of the disease extent after enhancement was assessed. Twenty seven avascular necrosis of the femoral head including 11 cases of bilateral lesion were detected. Fifteen cases revealed collapse of the femoral head. The portions of the lesion with low signal intensity on T1-weighted images and high signal intensity on T2-weighted images showed contrast enhancement in 15 cases. However, the potions with low signal intensities both on T1 and T2-weighted images showed enhancement in one case. There was no significant change of the disease extent after enhancement. Synovium showed enhancement in 18 cases, and joint effusion was detected in 23 cases. Contrast enhanced MR images may be helpful in predicting histopathologic findings of avascular necrosis of the femoral head, but not useful for evaluating the extent of disease

  10. Avascular necrosis of femoral head: findings of contrast-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Yong Moon; Kang, Heung Sik; Kim, Chu Wan; Kim, Hee Joong; Kim, Young Min [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1995-06-15

    To evaluate the findings and the role of contrast enhanced magnetic resonance imaging in avascular necrosis of femoral head. Sixteen patients with avascular necorsis of femoral head were examined with MRI. T1-weighted and T2-weighted image and contrast-enhanced T1-weighted images were obtained. Enhancing characteristics of the necrotic area and synovium were determined. Also a change of the disease extent after enhancement was assessed. Twenty seven avascular necrosis of the femoral head including 11 cases of bilateral lesion were detected. Fifteen cases revealed collapse of the femoral head. The portions of the lesion with low signal intensity on T1-weighted images and high signal intensity on T2-weighted images showed contrast enhancement in 15 cases. However, the potions with low signal intensities both on T1 and T2-weighted images showed enhancement in one case. There was no significant change of the disease extent after enhancement. Synovium showed enhancement in 18 cases, and joint effusion was detected in 23 cases. Contrast enhanced MR images may be helpful in predicting histopathologic findings of avascular necrosis of the femoral head, but not useful for evaluating the extent of disease.

  11. Frequent complications and severe bone loss associated with the repiphysis expandable distal femoral prosthesis.

    Science.gov (United States)

    Cipriano, Cara A; Gruzinova, Irina S; Frank, Rachel M; Gitelis, Steven; Virkus, Walter W

    2015-03-01

    The treatment of choice for distal femur malignancies in skeletally immature patients remains controversial. An expandable endoprosthesis device (Repiphysis Limb Salvage System; Wright Medical Technology, Arlington, TN, USA) allows for limb preservation and noninvasive lengthening but has been associated with significant complications; however, the extent and implications of bone loss associated with this implant have not been reported. Our goals were to report (1) the 2-year minimum clinical outcomes after placement of the Repiphysis expandable prosthesis for pediatric distal femur malignancies; (2) the complications associated with this prosthesis; (3) the failure rate of this prosthesis; and (4) the revision alternatives available for salvage procedures. Between 2002 and 2010, one surgeon (SG) treated all skeletally immature patients (mean age, 10.1 years; range, 4.7-13.6 years) with distal femoral osteosarcoma using a Repiphysis expandable prosthesis. Of the 12 patients who met these criteria, two were excluded for death from disease before 2 years, and mean followup for the remaining 10 was 72 months (range, 26-119 months). Medical records were retrospectively reviewed for complications and clinical outcomes, as assessed by the Musculoskeletal Tumor Society (MSTS) scoring system. Radiographs at final followup were reviewed for bone loss and analyzed by the two senior authors (SG, WWV) to determine reconstruction options available for future revisions. MSTS scores averaged 67%, and we observed 37 implant-related complications requiring a total of 15 reoperations. Six patients underwent implant revisions with aseptic loosening being the predominant mode of failure; ultimately, four of these were converted to adult modular oncology prostheses, and two underwent total femoral replacements. Bone loss in this series was severe in terms of femoral length, cortical thinning, and metadiaphyseal compromise, and most patients will not have sufficient bone stock to permit

  12. Avascular necrosis of the femoral head in HIV infected patients

    Directory of Open Access Journals (Sweden)

    Marcos Almeida Matos

    Full Text Available Avascular necrosis (AVN of the femoral head is an emerging complication in HIV infected patients. It has been suggested that the increased incidence of AVN in this population may be caused by an increased prevalence of predisposing factors for osteonecrosis, including protease inhibitors, hyperlipidemia, corticosteroid use, alcohol and intravenous drug abuse. The aim of this study was to assess the risk factors for avascular necrosis developing in the femoral head of HIV infected individuals. This study consisted of meta-analysis of the secondary data extracted from current literature. The selected articles allowed two study groups to be drawn up for comparison. Group 1 comprised 324 individuals infected by the HIV virus, who did not present femoral head AVN. Group 2 comprised 32 HIV positive patients, who presented femoral head AVN. The parameters used for analysis were as follows: age, gender, sexual preference, use of intravenous drugs, time of diagnosis, CD4+ cell count, use of antiretroviral agents and duration, serum cholesterol and serum triglycerides. The present study found a statistically significant association between hypertriglyceridemia, hypercholesterolemia, sexual preference and intravenous drug abuse. The authors concluded that femoral head osteonecrosis is associated with hyperlipidemia (hypercholesterolemia and hypertriglyceridemia and intravenous drug abuse. This study supports the hypothesis that protease inhibitors play a role in the development of osteonecrosis through a tendency to cause hyperlipidemia.

  13. Tunneling time, exit time and exit momentum in strong field tunnel ionization

    International Nuclear Information System (INIS)

    Teeny, Nicolas

    2016-01-01

    Tunnel ionization belongs to the fundamental processes of atomic physics. It is still an open question when does the electron tunnel ionize and how long is the duration of tunneling. In this work we solve the time-dependent Schroedinger equation in one and two dimensions and use ab initio quantum calculations in order to answer these questions. Additionally, we determine the exit momentum of the tunnel ionized electron from first principles. We find out results that are different from the assumptions of the commonly employed two-step model, which assumes that the electron ionizes at the instant of electric field maximum with a zero momentum. After determining the quantum final momentum distribution of tunnel ionized electrons we show that the two-step model fails to predict the correct final momentum. Accordingly we suggest how to correct the two-step model. Furthermore, we determine the instant at which tunnel ionization starts, which turns out to be different from the instant usually assumed. From determining the instant at which it is most probable for the electron to enter the tunneling barrier and the instant at which it exits we determine the most probable time spent under the barrier. Moreover, we apply a quantum clock approach in order to determine the duration of tunnel ionization. From the quantum clock we determine an average tunneling time which is different in magnitude and origin with respect to the most probable tunneling time. By defining a probability distribution of tunneling times using virtual detectors we relate both methods and explain the apparent discrepancy. The results found have in general an effect on the interpretation of experiments that measure the spectra of tunnel ionized electrons, and specifically on the calibration of the so called attoclock experiments, because models with imprecise assumptions are usually employed in order to interpret experimental results.

  14. Tunneling time, exit time and exit momentum in strong field tunnel ionization

    Energy Technology Data Exchange (ETDEWEB)

    Teeny, Nicolas

    2016-10-18

    Tunnel ionization belongs to the fundamental processes of atomic physics. It is still an open question when does the electron tunnel ionize and how long is the duration of tunneling. In this work we solve the time-dependent Schroedinger equation in one and two dimensions and use ab initio quantum calculations in order to answer these questions. Additionally, we determine the exit momentum of the tunnel ionized electron from first principles. We find out results that are different from the assumptions of the commonly employed two-step model, which assumes that the electron ionizes at the instant of electric field maximum with a zero momentum. After determining the quantum final momentum distribution of tunnel ionized electrons we show that the two-step model fails to predict the correct final momentum. Accordingly we suggest how to correct the two-step model. Furthermore, we determine the instant at which tunnel ionization starts, which turns out to be different from the instant usually assumed. From determining the instant at which it is most probable for the electron to enter the tunneling barrier and the instant at which it exits we determine the most probable time spent under the barrier. Moreover, we apply a quantum clock approach in order to determine the duration of tunnel ionization. From the quantum clock we determine an average tunneling time which is different in magnitude and origin with respect to the most probable tunneling time. By defining a probability distribution of tunneling times using virtual detectors we relate both methods and explain the apparent discrepancy. The results found have in general an effect on the interpretation of experiments that measure the spectra of tunnel ionized electrons, and specifically on the calibration of the so called attoclock experiments, because models with imprecise assumptions are usually employed in order to interpret experimental results.

  15. Quantum theory of tunneling

    CERN Document Server

    Razavy, Mohsen

    2014-01-01

    In this revised and expanded edition, in addition to a comprehensible introduction to the theoretical foundations of quantum tunneling based on different methods of formulating and solving tunneling problems, different semiclassical approximations for multidimensional systems are presented. Particular attention is given to the tunneling of composite systems, with examples taken from molecular tunneling and also from nuclear reactions. The interesting and puzzling features of tunneling times are given extensive coverage, and the possibility of measurement of these times with quantum clocks are critically examined. In addition by considering the analogy between evanescent waves in waveguides and in quantum tunneling, the times related to electromagnetic wave propagation have been used to explain certain aspects of quantum tunneling times. These topics are treated in both non-relativistic as well as relativistic regimes. Finally, a large number of examples of tunneling in atomic, molecular, condensed matter and ...

  16. Emergency Stenting of a Ruptured Infected Anastomotic Femoral Pseudoaneurysm

    International Nuclear Information System (INIS)

    Klonaris, Chris; Katsargyris, Athanasios; Matthaiou, Alexandros; Giannopoulos, Athanasios; Tsigris, Chris; Papadopouli, Katerina; Tsiodras, Sotiris; Bastounis, Elias

    2007-01-01

    A 74-year-old man presented with a ruptured infected anastomotic femoral pseudoaneurysm. Due to severe medical comorbidities he was considered unsuitable for conventional surgical management and underwent an emergency endovascular repair with a balloon-expandable covered stent. The pseudoaneurysm was excluded successfully and the patient had an uneventful postoperative recovery with long-term suppressive antimicrobials. He remained well for 10 months after the procedure with no signs of recurrent local or systemic infection and finally died from an acute myocardial infarction. To our knowledge, emergency endovascular treatment of a free ruptured bleeding femoral artery pseudoaneurysm has not been documented before in the English literature. This case illustrates that endovascular therapy may be a safe and efficient alternative in the emergent management of ruptured infected anastomotic femoral artery pseudoaneurysms when traditional open surgery is contraindicated

  17. Femoral Artery Stenosis Following Percutaneous Closure Using a Starclose Closure Device

    International Nuclear Information System (INIS)

    Bent, Clare Louise; Kyriakides, Constantinos; Matson, Matthew

    2008-01-01

    Starclose (Abbott Vascular Devices, Redwood City, CA) is a new arterial closure device that seals a femoral puncture site with an extravascular star-shaped nitinol clip. The clip projects small tines into the arterial wall which fold inward, causing the arterial wall to pucker, producing a purse-string-like seal closing the puncture site. The case history is that of a 76-year-old female patient who underwent day-case percutaneous diagnostic coronary angiography. A Starclose femoral artery closure device was used to achieve hemostasis with subsequent femoral artery stenosis.

  18. [Growth and deformity after in situ fixation of slipped capital femoral epiphysis].

    Science.gov (United States)

    Druschel, C; Placzek, R; Funk, J F

    2013-08-01

    For mild to moderate slipped capital femoral epiphysis (SCFE) in situ fixation is the current treatment standard. However, concerning the implant selection (screw versus k-wires) as well as the prophylactic stabilisation of the non-affected hip, controversies still exist. The aim of this study was to analyse femoral residual growth and femoral deformities after in situ fixation of SCFE either with k-wires or screws. We conducted a retrospective analysis of the radiographs of adolescents treated for SCFE in our department between 01/2003 and 02/2011. To evaluate femoral growth the articulo-trochanteric distance, centro-trochanteric distance, caput-collum-diaphyseal angle, pin-joint ratio and pin-physis ratio were determined. The femoral deformity was assessed by measuring the sphericity of the femoral head. Degenerative changes were evaluated in the final radiographs. Statistical analysis was performed concerning differences between therapeutically and prophylactically treated hips as well as stabilisations with k-wires and screws. A total of 22 patients (female : male = 14 : 8, mean age girls: 11 ± 1 years, boys: 13 ± 2 years) with 26 slipped capital femoral epiphyses was analysed. K-wires were used for fixation in 4 hips each therapeutically and prophylactically, 22 hips with SCFE and 14 non-affected hips were stabilised with screws. Treatment with screws did not lead to significantly earlier physeal closure than k-wire pinning. Regarding the femoral growth parameters a significant decrease in the articulo-trochanteric distance and CCD angle was detectable in all groups. The pin-joint ratio revealed an adequate residual growth in 58 % of the therapeutically and in 72 % of the prophylactically treated hips without significant difference between k-wires and screws. The pin-physis ratio demonstrated similar values. Regarding the femoral deformity the SCFE hips resulted in a significantly reduced sphericity, which remained unchanged during follow-up. The

  19. Improving band-to-band tunneling in a tunneling carbon nanotube field effect transistor by multi-level development of impurities in the drain region

    Science.gov (United States)

    Naderi, Ali; Ghodrati, Maryam

    2017-12-01

    In this paper, in order to improve the performance of a tunneling carbon nanotube field effect transistor (T-CNTFET) a new structure is proposed using multi-level impurity distribution along the drain region. The new T-CNTFET structure consists of six parts in the drain with stepwise doping distribution. The impurities on the drain side are n -type and the length of each region is 5nm. Electronic features of the proposed structure are simulated by the solution of Poisson and Schrödinger equations and the self-consistent method using Non-equilibrium Green's Function (NEGF). Simulation results show that the proposed structure reduces the band curvature near the drain-channel connection and widens the tunneling barrier. As a result, band-to-band tunneling and the OFF current are reduced and the ON/OFF current ratio increases in comparison with the conventional structure. In summary, by improving the subthreshold swing parameters, delay time, power delay product ( PDP and cut-off frequency compared to the conventional structure, the proposed structure can be considered as a proper candidate for digital applications with high speed and low power dissipation.

  20. A modified Larson’s method of posterolateral corner reconstruction of the knee reproducing the physiological tensioning pattern of the lateral collateral and popliteofibular ligaments

    Directory of Open Access Journals (Sweden)

    Niki Yasuo

    2012-06-01

    Full Text Available Abstract Background Consensus has been lacking as to how to reconstruct the posterolateral corner (PLC of the knee in patients with posterolateral instability. We describe a new reconstructive technique for PLC based on Larson's method, which reflects the physiological load-sharing pattern of the lateral collateral ligament (LCL and popliteofibular ligament (PFL. Findings Semitendinosus graft is harvested, and one limb of the graft comprises PFL and the other comprises LCL. Femoral bone tunnels for the LCL and popliteus tendon are made at their anatomical insertions. Fibular bone tunnel is prepared from the anatomical insertion of the LCL to the proximal posteromedial portion of the fibular head, which corresponds to the insertion of the PFL. The graft end for popliteus tendon is delivered into the femoral bone tunnel and secured on the medial femoral condyle. The other end for LCL is passed through the fibular tunnel from posterior to anterior. While the knee is held in 90 of flexion, the graft is secured in the fibular tunnel using a 5 mm interference screw. Then, the LCL end is passed into the femoral bone tunnel and secured at the knee in extension. Conclusions Differential tension patterns between LCL and PFL is critical when securing these graft limbs. Intrafibular fixation of the graft using a small interference screw allows us to secure these two graft limbs independently with intended tension at the intended flexion angle of the knee.

  1. Prognostic value of dynamic MRI in assessing post-traumatic femoral head vascularity

    Energy Technology Data Exchange (ETDEWEB)

    Kaushik, Abhishek; Varghese, Mathew [St Stephen' s Hospital, Department of Orthopaedics, Delhi, New Delhi (India); Sankaran, Balu [St Stephen' s Hospital, Delhi, New Delhi (India)

    2009-06-15

    The vascular status of femoral heads in the post-traumatic period of intracapsular femoral neck fracture (ICFNF) remains uncertain until the patient actually develops avascular necrosis (AVN). Several methods for predicting the viability of femoral head have been reported, that are not effective or widely used because of unreliability, potential complications, and technical difficulties. The present study involved the use of Dynamic MRI (DMRI) in assessing femoral head vascularity to predict AVN. The role of DMRI was studied prospectively in 30 patients with 31 ICFNF. Fractures were divided in to three types (Type A, B, or C) based on the femoral head vascularity shown by dynamic curve patterns on MRI evaluation. Type A was preserved vascularity, Type B was some decrease in vascularity but still viable while Type C was significantly reduced vascularity. These were followed-up for 6 months to 2 years to observe the final outcome in terms of union, non-union, or AVN. We found that Type A curves correlate well with vascular status and Type C curves correlate well with poor vascularity of the femoral heads. No AVN was seen in any of Type A (13/31) or Type B (eight out of 31). Five cases showed AVN and all of them were of Type C dynamic curves. Dynamic MRI is a reliable tool to evaluate vascularity of femoral heads and thus reduces the uncertainty of outcome of treatment of ICFNFs. DMRI can be a useful tool to formulate a treatment algorithm in management of ICFNF. (orig.)

  2. Arthroscopic treatment of femoral nerve paresthesia caused by an acetabular paralabral cyst.

    Science.gov (United States)

    Kanauchi, Taira; Suganuma, Jun; Mochizuki, Ryuta; Uchikawa, Shinichi

    2014-05-01

    This report describes a rare case of femoral nerve paresthesia caused by an acetabular paralabral cyst of the hip joint. A 68-year-old woman presented with a 6-month history of right hip pain and paresthesia along the anterior thigh and radiating down to the anterior aspect of the knee. Radiography showed osteoarthritis with a narrowed joint space in the right hip joint. Magnetic resonance imaging showed a cyst with low T1- and high T2-weighted signal intensity arising from a labral tear at the anterior aspect of the acetabulum. The cyst was connected to the joint space and displaced the femoral nerve to the anteromedial side. The lesion was diagnosed as an acetabular paralabral cyst causing femoral neuropathy. Because the main symptom was femoral nerve paresthesia and the patient desired a less invasive procedure, arthroscopic labral repair was performed to stop synovial fluid flow to the paralabral cyst that was causing the femoral nerve paresthesia. After surgery, the cyst and femoral nerve paresthesia disappeared. At the 18-month follow-up, the patient had no recurrence. There have been several reports of neurovascular compression caused by the cyst around the hip joint. To the authors' knowledge, only 3 cases of acetabular paralabral cysts causing sciatica have been reported. The current patient appears to represent a rare case of an acetabular paralabral cyst causing femoral nerve paresthesia. The authors suggest that arthroscopic labral repair for an acetabular paralabral cyst causing neuropathy can be an option for patients who desire a less invasive procedure. Copyright 2014, SLACK Incorporated.

  3. Prognostic value of dynamic MRI in assessing post-traumatic femoral head vascularity

    International Nuclear Information System (INIS)

    Kaushik, Abhishek; Varghese, Mathew; Sankaran, Balu

    2009-01-01

    The vascular status of femoral heads in the post-traumatic period of intracapsular femoral neck fracture (ICFNF) remains uncertain until the patient actually develops avascular necrosis (AVN). Several methods for predicting the viability of femoral head have been reported, that are not effective or widely used because of unreliability, potential complications, and technical difficulties. The present study involved the use of Dynamic MRI (DMRI) in assessing femoral head vascularity to predict AVN. The role of DMRI was studied prospectively in 30 patients with 31 ICFNF. Fractures were divided in to three types (Type A, B, or C) based on the femoral head vascularity shown by dynamic curve patterns on MRI evaluation. Type A was preserved vascularity, Type B was some decrease in vascularity but still viable while Type C was significantly reduced vascularity. These were followed-up for 6 months to 2 years to observe the final outcome in terms of union, non-union, or AVN. We found that Type A curves correlate well with vascular status and Type C curves correlate well with poor vascularity of the femoral heads. No AVN was seen in any of Type A (13/31) or Type B (eight out of 31). Five cases showed AVN and all of them were of Type C dynamic curves. Dynamic MRI is a reliable tool to evaluate vascularity of femoral heads and thus reduces the uncertainty of outcome of treatment of ICFNFs. DMRI can be a useful tool to formulate a treatment algorithm in management of ICFNF. (orig.)

  4. A new method for measurement of femoral anteversion using 3D imaging technique

    International Nuclear Information System (INIS)

    Kim, S.I.; Lee, Y.H.; Park, S.-B.; Lee, K.-M.

    1996-01-01

    Conventional methods that use cross-sectional computed tomography (CT) images to estimate femoral anteversion have several problems because of the complex 3 dimensional structure of the femur. These are the ambiguity of defining the femoral neck axis and condylar line, and the dependence on patient positioning. Especially, the femoral neck axis that is known as a major source of error is hard to determine from a single or multiple 2-dimensional transverse CT images. In this study, we are presenting a new method that we have devised form the measurement of femoral anteversion by utilizing the 3 dimensional imaging technique. Poster 176. (author)

  5. Long-term functional outcome following intramedullary nailing of femoral shaft fractures

    NARCIS (Netherlands)

    el Moumni, Mostafa; Voogd, Emma Heather; ten Duis, Henk Jan; Wendt, Klaus Wilhelm

    Background: The management of femoral shaft fractures using intramedullary nailing is a popular method. The purpose of this study was to evaluate the long-term functional outcome after antegrade or retrograde intramedullary nailing of traumatic femoral shaft fractures. We further determined

  6. Hydrochemistry of urban groundwater, Seoul, Korea: the impact of subway tunnels on groundwater quality.

    Science.gov (United States)

    Chae, Gi-Tak; Yun, Seong-Taek; Choi, Byoung-Young; Yu, Soon-Young; Jo, Ho-Young; Mayer, Bernhard; Kim, Yun-Jong; Lee, Jin-Yong

    2008-10-23

    Hydrogeologic and hydrochemical data for subway tunnel seepage waters in Seoul (Republic of Korea) were examined to understand the effect of underground tunnels on the degradation of urban groundwater. A very large quantity of groundwater (up to 63 million m3 year(-1)) is discharged into subway tunnels with a total length of 287 km, resulting in a significant drop of the local groundwater table and the abandonment of groundwater wells. For the tunnel seepage water samples (n = 72) collected from 43 subway stations, at least one parameter among pathogenic microbes (total coliform, heterotrophic bacteria), dissolved Mn and Fe, NH4+, NO3(-), turbidity, and color exceeded the Korean Drinking Water Standards. Locally, tunnel seepage water was enriched in dissolved Mn (avg. 0.70 mg L(-1), max. 5.58 mg L(-1)), in addition to dissolved Fe, NH4+, and pathogenic microbes, likely due to significant inflow of sewage water from broken or leaking sewer pipes. Geochemical modeling of redox reactions was conducted to simulate the characteristic hydrochemistry of subway tunnel seepage. The results show that variations in the reducing conditions occur in urban groundwater, dependent upon the amount of organic matter-rich municipal sewage contaminating the aquifer. The organic matter facilitates the reduction and dissolution of Mn- and Fe-bearing solids in aquifers and/or tunnel construction materials, resulting in the successive increase of dissolved Mn and Fe. The present study clearly demonstrates that locally significant deterioration of urban groundwater is caused by a series of interlinked hydrogeologic and hydrochemical changes induced by underground tunnels.

  7. The Kinematic and Static Analysis of the Tibio-Femoral Joint Based on a Novel Spatial Mechanism

    Directory of Open Access Journals (Sweden)

    Yonggang Xu

    2012-11-01

    Full Text Available To reveal the characteristics of knee movement and tibio-femoral joint contact force, a novel single degree of freedom spatial mechanism is built to simulate the joint kinematics based on a three dimensional model of the human knee. The length changes of the three ligaments can be obtained by establishing and solving the kinematics spiral function. Based on this mechanism, a static model is built where linear springs are used to model the ligaments and whose stiffness coefficients are obtained by the finite element method. The main strength of the proposed model is that it associates the knee's flexion motion with internal/external rotation of the tibia based on the isometricity of the anterior cruciate ligament. This offers an efficient method to model and analyse the changes of ligament lengths and static kinematics after ligament reconstruction, which is crucial in designing knee recovery and rehabilitation equipment.

  8. Radon hazard from caisson and tunnel construction in Kong Kong

    International Nuclear Information System (INIS)

    Lam, W.K.; Tsin, T.W.; Ng, T.P.

    1988-01-01

    A possible occupational risk of caisson and tunnel excavation in Hong Kong results from the inhalation of natural radon daughters. In this study radon daughter concentrations ranging from 0.001 to 71.4 WL were recorded in caissons of various dimensions and from 0.03 to 0.95 WL in tunnels over 1 km in length under construction (ICRP exposure limit being 0.4 WL). There was clear indication of increased radon daughter accumulation in confined and unventilated areas and in unventilated caissons an exponential increase of radon daughter concentration with the ratio of depth to cross-sectional area was observed (r=0.9). The study revealed a potential radiation hazard facing underground construction workers and this is being examined by an ongoing epidemiological cohort study: meanwhile environmental control should be improved. (UK)

  9. Development of remote controlled blasting system for tunnels; Tunnel yo enkaku seigyo happa system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, S.; Kawamura, M.; Hirosaki, Y. [NOF Corp., Aichi (Japan)

    1997-06-30

    A downsized wireless blasting system has been developed for tunnel construction in the mountainous districts. This system consists of an oscillator, loop antenna, and initiator. The ac magnetic field is generated in the loop antenna using 550 Hz ac generated by the oscillator, to induce the electro motive force between both ends of receiver coil in the initiator. It is stored in the capacitor after rectification, to initiate the detonator by discharging with the firing signal. This system has been developed by downsizing the conventional RCB (remote controlled blasting system) for underwater blasting, and unmanned operation is planned in future. An oscillation frequency, 550 Hz with an actual result has been adopted. The arm length of loop antenna is 3 m, which can be installed in the tunnel. Various receiver initiators were fabricated as a trial. A convex type was adopted due to its excellent receiving performance. The receiving performance was improved by increasing the magnetic induction and decreasing the power loss. After receiving voltage of the receiver initiator was confirmed, field initiation tests were conducted. Initiating and blasting were successfully carried out. 5 refs., 15 figs., 3 tabs.

  10. Bilateral impacted femoral neck fracture in a renal disease patient ...

    African Journals Online (AJOL)

    Spontaneous bilateral femoral neck facture in a renal disease patient is not common. We report a case of 47-year-old female patient with chronic renal failure and on regular hemodialysis for the past 5 years who sustained bilateral impacted femoral neck fracture without history of trauma and injury and refused any surgical ...

  11. Geochemical study of acid mine drainage of the Big Lick Tunnel area, Williamstown, PA

    International Nuclear Information System (INIS)

    Tollin, S.

    1993-01-01

    Acid mine drainage in the anthracite region of Pennsylvania continues to be a significant environmental problem. This study examines the acid mine outflow from the Big Lick Tunnel, north of Williamstown, Dauphin County, Pennsylvania. The tunnel drains abandoned mines on the north side of the Big Lick Mountain. Mining ceased in the area circa 1940, and the tunnel has been in operation since that time. The water, soil and stream bed sediment geochemistry has been studied to determine their changes in chemistry over distance. The pH, TDS and metal concentrations were the primary focus. Metal concentrations were determined using an ICP unit. Data indicates the pH of the outflow to range between 6.7 and 7.3 Fe and Mn concentrations are as high as 9.7 ppb. Extensive metal precipitation (''yellow boy'') occurs within the tunnel and for several hundred meters from the mouth of the tunnel. The combination of near neutral pH and high metal concentration suggest that the drainage is in contact with highly alkaline materials prior to discharge from the tunnel. The geology of the area does not suggest bedrock as the possible source of alkaline material. One hypothesis is that the acidic water is reacting with the concrete tunnel and being neutralized. Data also suggests that the Fe precipitates much quicker than the Mn, resulting in a zonation between Fe-rich and Mn-rich sediments along the length of the drainage

  12. Benefit of cup medialization in total hip arthroplasty is associated with femoral anatomy.

    Science.gov (United States)

    Terrier, Alexandre; Levrero Florencio, Francesc; Rüdiger, Hannes A

    2014-10-01

    Medialization of the cup with a respective increase in femoral offset has been proposed in THA to increase abductor moment arms. Insofar as there are potential disadvantages to cup medialization, it is important to ascertain whether the purported biomechanical benefits of cup medialization are large enough to warrant the downsides; to date, studies regarding this question have disagreed. The purpose of this study was to quantify the effect of cup medialization with a compensatory increase in femoral offset compared with anatomic reconstruction for patients undergoing THA. We tested the hypothesis that there is a (linear) correlation between preoperative anatomic parameters and muscle moment arm increase caused by cup medialization. Fifteen patients undergoing THA were selected, covering a typical range of preoperative femoral offsets. For each patient, a finite element model was built based on a preoperative CT scan. The model included the pelvis, femur, gluteus minimus, medius, and maximus. Two reconstructions were compared: (1) anatomic position of the acetabular center of rotation, and (2) cup medialization compensated by an increase in the femoral offset. Passive abduction-adduction and flexion-extension were simulated in the range of normal gait. Muscle moment arms were evaluated and correlated to preoperative femoral offset, acetabular offset, height of the greater trochanter (relative to femoral center of rotation), and femoral antetorsion angle. The increase of muscle moment arms caused by cup medialization varied among patients. Muscle moment arms increase by 10% to 85% of the amount of cup medialization for abduction-adduction and from -35% (decrease) to 50% for flexion-extension. The change in moment arm was inversely correlated (R(2) = 0.588, p = 0.001) to femoral antetorsion (anteversion), such that patients with less femoral antetorsion gained more in terms of hip muscle moments. No linear correlation was observed between changes in moment arm and

  13. Size dependence of spin-torque induced magnetic switching in CoFeB-based perpendicular magnetization tunnel junctions (invited)

    Science.gov (United States)

    Sun, J. Z.; Trouilloud, P. L.; Gajek, M. J.; Nowak, J.; Robertazzi, R. P.; Hu, G.; Abraham, D. W.; Gaidis, M. C.; Brown, S. L.; O'Sullivan, E. J.; Gallagher, W. J.; Worledge, D. C.

    2012-04-01

    CoFeB-based magnetic tunnel junctions with perpendicular magnetic anisotropy are used as a model system for studies of size dependence in spin-torque-induced magnetic switching. For integrated solid-state memory applications, it is important to understand the magnetic and electrical characteristics of these magnetic tunnel junctions as they scale with tunnel junction size. Size-dependent magnetic anisotropy energy, switching voltage, apparent damping, and anisotropy field are systematically compared for devices with different materials and fabrication treatments. Results reveal the presence of sub-volume thermal fluctuation and reversal, with a characteristic length-scale of the order of approximately 40 nm, depending on the strength of the perpendicular magnetic anisotropy and exchange stiffness. To have the best spin-torque switching efficiency and best stability against thermal activation, it is desirable to optimize the perpendicular anisotropy strength with the junction size for intended use. It also is important to ensure strong exchange-stiffness across the magnetic thin film. These combine to give an exchange length that is comparable or larger than the lateral device size for efficient spin-torque switching.

  14. Spin-dependent tunnelling in magnetic tunnel junctions

    International Nuclear Information System (INIS)

    Tsymbal, Evgeny Y; Mryasov, Oleg N; LeClair, Patrick R

    2003-01-01

    The phenomenon of electron tunnelling has been known since the advent of quantum mechanics, but continues to enrich our understanding of many fields of physics, as well as creating sub-fields on its own. Spin-dependent tunnelling (SDT) in magnetic tunnel junctions (MTJs) has recently aroused enormous interest and has developed in a vigorous field of research. The large tunnelling magnetoresistance (TMR) observed in MTJs garnered much attention due to possible applications in non-volatile random-access memories and next-generation magnetic field sensors. This led to a number of fundamental questions regarding the phenomenon of SDT. In this review article we present an overview of this field of research. We discuss various factors that control the spin polarization and magnetoresistance in MTJs. Starting from early experiments on SDT and their interpretation, we consider thereafter recent experiments and models which highlight the role of the electronic structure of the ferromagnets, the insulating layer, and the ferromagnet/insulator interfaces. We also discuss the role of disorder in the barrier and in the ferromagnetic electrodes and their influence on TMR. (topical review)

  15. Femoral artery recanalisation with percutaneous angioplasty and segmentally enclosed plasminogen activator

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Bülow, J

    1989-01-01

    To establish whether re-occlusion of the femoral artery could be prevented, in 6 consecutive patients undergoing percutaneous transluminal angioplasty (PTA) for superficial femoral artery occlusion the recanalised segment was isolated, with a 7-French double-balloon catheter. 5 mg recombined huma...

  16. Biomechanical considerations in slipped capital femoral epiphysis and insights into prophylactic fixation.

    Science.gov (United States)

    Leblanc, E; Bellemore, J M; Cheng, T; Little, D G; Birke, O

    2017-04-01

    Slipped capital femoral epiphysis (SCFE) is a deformity of the proximal femur secondary to widened and unstable physis. In stabilising the slip, gold standard treatments stop growth and involve premature physeal closure, which prevents the remodelling of the acquired deformity and creates a leg length discrepancy that may be significant in younger patients. We measured the impact of placing threaded screws across the proximal femoral physis by measuring the centre-trochanteric distance (CTD) and articulo-trochanteric distance (ATD) in participants with or without prophylactic fixation. We then compared the mechanical performance of static (stainless and titanium cannulated Synthes screws) and potentially growing implants (Synthes SCFE screw and Pega Medical Free Gliding screw) in a validated synthetic bone model. In the review of 30 non-fixed and 60 fixated hips over a mean follow-up of 1.9 years, we have noted a significant difference in pre/post CTD and ATD, as well as the change in CTD and ATD over time. In the biomechanical study, the newer implants allowing growth (Synthes SCFE screw and Pega Medical Free Gliding screw) were both shown to be at least non-inferior. The primary deformity of a SCFE in itself alters hip mechanics. Also, as confirmed in this study, there is a secondary deformity that is created by static fixation and relative trochanteric overgrowth. To help remodel mild deformities and prevent secondary trochanteric overgrowth, growing implants seem to be non-inferior to the more standard means of fixation in static testing.

  17. Sub-electron transport in single-electron-tunneling arrays

    Science.gov (United States)

    Kaplan, Daniel; Sverdlov, Viktor; Korotkov, Alexander; Likharev, Konstantin

    2002-03-01

    We have analyzed quasi-continuous charge transport in two-dimensional tunnel junction arrays with a special distribution of background charges, providing a complete suppression of Coulomb blockade thresholds of tunneling between any pair of islands. Numerical simulations show that at low currents the dc I-V curve is indeed linear, while the shot noise is strongly suppressed and approaches 1/N of the Schottky value (where N is the array length). Thus both conditions of quasi-continuous transport, formulated earlier by Matsuoka and Likharev (Phys. Rev. B, v57, 15613, 1998), are satisfied. At higher fields the electron-hole pair production begins, and shot noise grows sharply. At higher voltages still, the array enters the "plasma" regime (with nearly balanced number of electrons and holes) and the Fano factor drops to 1/N once again. We have studied the resulting shot noise peak in detail, and concluded that its physics is close to that of critical opalescence.

  18. The stability of the femoral component of a minimal invasive total hip replacement system.

    NARCIS (Netherlands)

    Willems, M.M.M.; Kooloos, J.G.M.; Gibbons, P.; Minderhoud, N.; Weernink, T.; Verdonschot, N.J.J.

    2006-01-01

    In this study, the initial stability of the femoral component of a minimal invasive total hip replacement was biomechanically evaluated during simulated normal walking and chair rising. A 20 mm diameter canal was created in the femoral necks of five fresh frozen human cadaver bones and the femoral

  19. Computer tomographic determination of femoral anteversion

    International Nuclear Information System (INIS)

    Jend, H.H.

    1986-01-01

    Thirty-two macerated femora were examined by CT in order to determine the degree of anteversion and to relate this to the position of the femur and to the various reference lines quoted in the literature. The accuracy of CT is the same as that of the Rippstein method, provided the following conditions are met: 1. Position of the femur with its long axis perpendicular to the image plane. 2. Demonstration of the maximal configuration of the femoral condyles to enable one to construct a tangent to the dorsal aspect of the condyle. 3. Demonstration of the head and neck by a plane which divides the neck into approximately equal portions and sections the femoral head. These conditions are more easily met, even in immobile patients, than the requirements for the Rippstein method. (orig.) [de

  20. Rotation of intramedullary alignment rods affects distal femoral cutting plane in total knee arthroplasty.

    Science.gov (United States)

    Maderbacher, Günther; Matussek, Jan; Keshmiri, Armin; Greimel, Felix; Baier, Clemens; Grifka, Joachim; Maderbacher, Hermann

    2018-02-17

    Intramedullary rods are widely used to align the distal femoral cut in total knee arthroplasty. We hypothesised that both coronal (varus/valgus) and sagittal (extension/flexion) cutting plane are affected by rotational changes of intramedullary femoral alignment guides. Distal femoral cuts using intramedullary alignment rods were simulated by means of a computer-aided engineering software in 4°, 6°, 8°, 10°, and 12° of valgus in relation to the femoral anatomical axis and 4° extension, neutral, as well as 4°, 8°, and 12° of flexion in relation to the femoral mechanical axis. This reflects the different angles between anatomical and mechanical axis in coronal and sagittal planes. To assess the influence of rotation of the alignment guide on the effective distal femoral cutting plane, all combinations were simulated with the rod gradually aligned from 40° of external to 40° of internal rotation. Rotational changes of the distal femoral alignment guides affect both the coronal and sagittal cutting planes. When alignment rods are intruded neutrally with regards to sagittal alignment, external rotation causes flexion, while internal rotation causes extension of the sagittal cutting plane. Simultaneously the coronal effect (valgus) decreases resulting in an increased varus of the cutting plane. However, when alignment rods are intruded in extension or flexion partly contradictory effects are observed. Generally the effect increases with the degree of valgus preset, rotation and flexion. As incorrect rotation of intramedullary alignment guides for distal femoral cuts causes significant cutting errors, exact rotational alignment is crucial. Coronal cutting errors in the distal femoral plane might result in overall leg malalignment, asymmetric extension gaps and subsequent sagittal cutting errors.

  1. Variant Branching of the Common Femoral Artery in a Black Kenyan ...

    African Journals Online (AJOL)

    Branching pattern of common femoral artery is important during artery catheterization, orthopaedic, plastic and general surgery in the proximal thigh. Frequency of variant branching shows ethnic variation but there are no data for black African populations. Since atherosclerotic diseases are increasing and femoral artery ...

  2. Analysis of hemodynamic characteristics in anastomotic sites of femoral artery implantation

    Energy Technology Data Exchange (ETDEWEB)

    Roh, H.W. [Graduate School, Soongsil University, Seoul (Korea); Suh, S.H. [SoongsSil University, Seoul (Korea); Yoo, S.S. [Hankuk Aviation University, Kyonggi-do (Korea); Kim, D.I.; Lee, B.B. [Samsung Medical Center (Korea)

    1998-11-01

    The objective of the present study is to obtain information on the hemodynamic characteristics in the anastomotic sites of femoral artery through the vascular implantation. Three dimensional steady and physiological blood flows in the femoral artery are simulated using the finite volume method. The geometrical shape of the anastomotic sites is made based on the vascular anatomy of a white rabbit. Wall shear stress distributions in the anastomotic sites for the physiological flow are compared with those for steady flow. Blood flow phenomena in the anastomotic sites of the femoral artery are discussed extensively. (author). 9 refs., 11 figs., 1 tab.

  3. Shielding synchrotron light sources: Advantages of circular shield walls tunnels

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, S.L. [Design and Accelerator Operations Consulting, 568 Wintergreen Ct Ridge, NY 11961 (United States); Ghosh, V.J.; Breitfeller, M. [NSLS-II, Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2016-08-11

    Third generation high brightness light sources are designed to have low emittance and high current beams, which contribute to higher beam loss rates that will be compensated by Top-Off injection. Shielding for these higher loss rates will be critical to protect the projected higher occupancy factors for the users. Top-Off injection requires a full energy injector, which will demand greater consideration of the potential abnormal beam miss-steering and localized losses that could occur. The high energy electron injection beam produce significantly higher neutron component dose to the experimental floor than lower energy injection and ramped operations. High energy neutrons produced in the forward direction from thin target beam losses are a major component of the dose rate outside the shield walls of the tunnel. The convention has been to provide thicker 90° ratchet walls to reduce this dose to the beam line users. We present an alternate circular shield wall design, which naturally and cost effectively increases the path length for this forward radiation in the shield wall and thereby substantially decreasing the dose rate for these beam losses. This shield wall design will greatly reduce the dose rate to the users working near the front end optical components but will challenge the beam line designers to effectively utilize the longer length of beam line penetration in the shield wall. Additional advantages of the circular shield wall tunnel are that it's simpler to construct, allows greater access to the insertion devices and the upstream in tunnel beam line components, as well as reducing the volume of concrete and therefore the cost of the shield wall.

  4. The application of bilateral femoral vein approaches in interventional treatment of deep venous thrombosis of left lower extremity

    International Nuclear Information System (INIS)

    Wang Xiuping; Liu Jian; Wang Bin; Yao Zhongqiang; Zhang Yan; Li Chen

    2011-01-01

    Objective: To investigate the feasibility of interventional catheterization with bilateral femoral vein approaches for performing the thrombolytic treatment of acute deep venous thrombosis of left lower extremity. Methods: Antegrade puncturing into the left femoral vein was carried out in eighteen patients with acute deep vein thrombosis in the left lower extremity after left iliac-femoral vein catheterization via the right femoral vein or the right jugular vein access failed. When the puncturing of the left femoral vein was successfully done and was confirmed by angiography, the guide wire was inserted into the inferior vena cava and was pulled out through the right femoral vein or right jugular vein, and a wire track was thus established. Then, retrograde insertion of the catheter was conducted along the wire from the right to the left until the catheter was placed into the left iliac-femoral vein for thrombolysis. Results: Of 18 cases,successful puncturing into the left femoral vein was achieved in 16, and an effective wire track was established between the left and right femoral veins, based on which the catheter was smoothly inserted into the left iliac-femoral vein via the right femoral vein or jugular vein. Catheter thrombolysis was employed for 3 to 14 days, the thrombus was completely dissolved and the lower extremity swelling subsided. During the course of thrombolysis, no obvious congestion or hematoma occurred at the puncturing site of the left femoral vein. Conclusion: For patients with deep vein thrombosis of left lower extremity, when left iliac-femoral vein catheterization via the right femoral vein or the right jugular vein access failed, the establishment of wire track by using bilateral femoral vein approaches for further catheterization of left iliac-femoral vein and subsequent thrombolysis is feasible in clinical practice. This technique is safe and minimally-invasive with higher success rate. (authors)

  5. The application of PRP combined with TCP in repairing avascular necrosis of the femoral head after femoral neck fracture in rabbit.

    Science.gov (United States)

    Zhang, X-L; Wang, Y-M; Chu, K; Wang, Z-H; Liu, Y-H; Jiang, L-H; Chen, X; Zhou, Z-Y; Yin, G

    2018-02-01

    In view of the high occurrence of avascular necrosis of the femoral head (ANFH) after femoral neck fracture and the difficulties in the treatment, our work aimed to explore the effects of platelet-rich plasma (PRP) combined with tri-calcium phosphate (TCP) on the repair of ANFH after femoral neck fracture and to provide reference for clinical treatment. Thirty New Zealand white rabbits were randomly divided into control group, TCP group, and PRP+TCP group. The rabbit ANFH model was established and femoral head tissues were collected. HE staining was used for histological observation. Image analysis and statistical analysis were used to calculate the New Bone Area fraction (NBA %). The levels of bone morphogenetic protein (BMP)-7, transforming growth factor (TGF)-β1, basic fibroblast growth factor (bFGF), interleukin (IL)-6 and tumor necrosis factor (TNF)-a in serum were detected by Enzyme-Linked ImmunoSorbent Assay (ELISA). The new bone area of TCP group was significantly lower than that of PRP+TCP group (pPRP+TCP groups (pPRP+TCP group was higher than that in TCP group. TCP and PRP+TCP can both significantly reduce the content of IL-6 and TNF-a (pPRP+TCP group compared with the TCP group at 8 weeks after injection. PRP combined with TCP, which can promote new bone formation and inhibit inflammatory response, showed higher efficiency in repairing ANFH than internal fixation alone.

  6. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic cemented or... Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be implanted...

  7. Radiation-induced femoral head necrosis

    African Journals Online (AJOL)

    2011-03-25

    Mar 25, 2011 ... had open medial menisectomy of the left knee following medial meniscal tear ... postoperative recovery and mobilised full weight-bearing immediately [Figure 6]. ... obtained from the oncologists at the time of this review), and there was a ... previous trauma such as femoral neck fracture, Gaucher's disease ...

  8. Tunnel fire dynamics

    CERN Document Server

    Ingason, Haukur; Lönnermark, Anders

    2015-01-01

    This book covers a wide range of issues in fire safety engineering in tunnels, describes the phenomena related to tunnel fire dynamics, presents state-of-the-art research, and gives detailed solutions to these major issues. Examples for calculations are provided. The aim is to significantly improve the understanding of fire safety engineering in tunnels. Chapters on fuel and ventilation control, combustion products, gas temperatures, heat fluxes, smoke stratification, visibility, tenability, design fire curves, heat release, fire suppression and detection, CFD modeling, and scaling techniques all equip readers to create their own fire safety plans for tunnels. This book should be purchased by any engineer or public official with responsibility for tunnels. It would also be of interest to many fire protection engineers as an application of evolving technical principles of fire safety.

  9. Krypton Derivatization of an O2 -Tolerant Membrane-Bound [NiFe] Hydrogenase Reveals a Hydrophobic Tunnel Network for Gas Transport.

    Science.gov (United States)

    Kalms, Jacqueline; Schmidt, Andrea; Frielingsdorf, Stefan; van der Linden, Peter; von Stetten, David; Lenz, Oliver; Carpentier, Philippe; Scheerer, Patrick

    2016-04-25

    [NiFe] hydrogenases are metalloenzymes catalyzing the reversible heterolytic cleavage of hydrogen into protons and electrons. Gas tunnels make the deeply buried active site accessible to substrates and inhibitors. Understanding the architecture and function of the tunnels is pivotal to modulating the feature of O2 tolerance in a subgroup of these [NiFe] hydrogenases, as they are interesting for developments in renewable energy technologies. Here we describe the crystal structure of the O2 -tolerant membrane-bound [NiFe] hydrogenase of Ralstonia eutropha (ReMBH), using krypton-pressurized crystals. The positions of the krypton atoms allow a comprehensive description of the tunnel network within the enzyme. A detailed overview of tunnel sizes, lengths, and routes is presented from tunnel calculations. A comparison of the ReMBH tunnel characteristics with crystal structures of other O2 -tolerant and O2 -sensitive [NiFe] hydrogenases revealed considerable differences in tunnel size and quantity between the two groups, which might be related to the striking feature of O2 tolerance. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Proton tunneling in solids

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, J.

    1998-10-01

    The tunneling rate of the proton and its isotopes between interstitial sites in solids is studied theoretically. The phonons and/or the electrons in the solid have two effects on the tunneling phenomenon. First, they suppress the transfer integral between two neighbouring states. Second, they give rise to a finite lifetime of the proton state. Usually the second effect is large and the tunneling probability per unit time (tunneling rate) can be defined. In some cases, however, a coherent tunneling is expected and actually observed. (author)

  11. Proton tunneling in solids

    International Nuclear Information System (INIS)

    Kondo, J.

    1998-01-01

    The tunneling rate of the proton and its isotopes between interstitial sites in solids is studied theoretically. The phonons and/or the electrons in the solid have two effects on the tunneling phenomenon. First, they suppress the transfer integral between two neighbouring states. Second, they give rise to a finite lifetime of the proton state. Usually the second effect is large and the tunneling probability per unit time (tunneling rate) can be defined. In some cases, however, a coherent tunneling is expected and actually observed. (author)

  12. Valsalva and gravitational variability of the internal jugular vein and common femoral vein: Ultrasound assessment

    Energy Technology Data Exchange (ETDEWEB)

    Beddy, P. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland)]. E-mail: pbeddy@eircom.net; Geoghegan, T. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Ramesh, N. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Buckley, O. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); O' Brien, J. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Colville, J. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Torreggiani, W.C. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland)

    2006-05-15

    Purpose: Central venous cannulation via the common femoral vein is an important starting point for many interventions. The purpose of this study was to determine the optimum conditions for cannulation of the femoral vein and to compare these with the relative changes in the internal jugular vein. Methods: High-resolution 2D ultrasound was utilised to determine variability of the calibre of the femoral and internal jugular veins in 10 healthy subjects. Venous diameter was assessed during the Valsalva manoeuvre and in different degrees of the Trendelenburg position. Results: The Valsalva manoeuvre significantly increased the size of the femoral and internal jugular veins. There was a relatively greater increase in femoral vein diameter when compared with the internal jugular vein of 40 and 29%, respectively. Changes in body inclination (Trendelenburg position) did not significantly alter the luminal diameter of the femoral vein. However, it significantly increased internal jugular vein diameter. Conclusions: Femoral vein cannulation is augmented by the Valsalva manoeuvre but not significantly altered by the gravitational position of the subject.

  13. Development and Validation of a Path Length Calculation for Carotid-Femoral Pulse Wave Velocity Measurement: A TASCFORCE, SUMMIT, and Caerphilly Collaborative Venture.

    Science.gov (United States)

    Weir-McCall, Jonathan R; Brown, Liam; Summersgill, Jennifer; Talarczyk, Piotr; Bonnici-Mallia, Michael; Chin, Sook C; Khan, Faisel; Struthers, Allan D; Sullivan, Frank; Colhoun, Helen M; Shore, Angela C; Aizawa, Kunihiko; Groop, Leif; Nilsson, Jan; Cockcroft, John R; McEniery, Carmel M; Wilkinson, Ian B; Ben-Shlomo, Yoav; Houston, J Graeme

    2018-05-01

    Current distance measurement techniques for pulse wave velocity (PWV) calculation are susceptible to intercenter variability. The aim of this study was to derive and validate a formula for this distance measurement. Based on carotid femoral distance in 1183 whole-body magnetic resonance angiograms, a formula was derived for calculating distance. This was compared with distance measurements in 128 whole-body magnetic resonance angiograms from a second study. The effects of recalculation of PWV using the new formula on association with risk factors, disease discrimination, and prediction of major adverse cardiovascular events were examined within 1242 participants from the multicenter SUMMIT study (Surrogate Markers of Micro- and Macrovascular Hard End-Points for Innovative Diabetes Tools) and 825 participants from the Caerphilly Prospective Study. The distance formula yielded a mean error of 7.8 mm (limits of agreement =-41.1 to 56.7 mm; P measurement, the distance formula did not change associations between PWV and age, blood pressure, or creatinine ( P accounting for differences in age, sex, and mean arterial pressure, intercenter differences in PWV persisted using the external distance measurement ( F =4.6; P =0.004), whereas there was a loss of between center difference using the distance formula ( F =1.4; P =0.24). PWV odds ratios for cardiovascular mortality remained the same using both the external distance measurement (1.14; 95% confidence interval, 1.06-1.24; P =0.001) and the distance formula (1.17; 95% confidence interval, 1.08-1.28; P measurement variability without impacting the diagnostic utility of carotid-femoral PWV. © 2018 The Authors.

  14. Multiplanar CT assessment of femoral head displacement in slipped capital femoral epiphysis

    Energy Technology Data Exchange (ETDEWEB)

    Monazzam, Shafagh [Rady Children' s Hospital and Health Center, Department of Orthopedics, San Diego, CA (United States); Dwek, Jerry R. [Rady Children' s Hospital and Health Center, Department of Radiology, San Diego, CA (United States); Hosalkar, Harish S. [Center for Hip Preservation, Department of Orthopedic Surgery, TriCity Medical Center, Oceanside, CA (United States)

    2013-12-15

    With recent changing approaches to the management of slipped capital femoral epiphysis (SCFE), the accurate radiographic assessment of maximum extent of displacement is crucial for planning surgical treatment. To determine what plane best represents the maximum SCFE displacement as quantified by the head-neck angle difference (HNAD), whether HNAD can quantitatively differentiate the SCFE cohort from the normal cohort, based on CT, and how Southwick slip angle (SSA) compares to HNAD. We reviewed 19 children with SCFE (23 affected hips) with preoperative CT scans and 27 age- and sex-matched children undergoing abdominal CT for non-orthopedic problems. Head-neck angle (HNA), the angle between the femoral epiphysis and the neck axis, was measured in three planes on each hip and the HNAD (affected - unaffected hip) was determined. SSA was measured on radiographs. The coronal HNAD (mean 8.7 ) was less than both the axial-oblique (mean 30.7 ) and sagittal (mean 37.4 ) HNADs, which were also greater than the HNADs of the normal cohort. Grouping HNAD measurements by SSA severity classification did not consistently distinguish between SCFE severity levels. Axial-oblique and sagittal planes best represent the maximum SCFE displacement while biplanar radiograph may underestimate the extent of the displacement, thereby potentially altering the management between in situ pinning and capital realignment. (orig.)

  15. Three-year results after directional atherectomy of calcified stenotic lesions of the superficial femoral artery.

    Science.gov (United States)

    Minko, P; Buecker, A; Jaeger, S; Katoh, M

    2014-10-01

    To investigate the 3-year outcome of patients with peripheral arterial disease (PAD) and heavily calcified stenotic lesions of the superficial femoral artery after directional atherectomy. Fifty-three patients (mean age 67 ± 10 years; 18 females, 35 males, TASC B and C, mean lesion length 7.9 ± 3.5 cm) with PAD (Rutherford 2-6) were enrolled into this prospective monocentric study. In total, 59 calcified lesions of the superficial femoral artery were treated with the Silverhawk atherectomy device (Covidien, Plymouth, MN, USA). Patients were followed-up for 36 months with a 6-month interval to perform clinical re-evaluation, including measurement of maximum walking distance and ankle-brachial index (ABI) as well as duplex-sonography. The primary success rate of the procedure was 92 %. In five cases (8 %), additional balloon-PTA and/or stent-PTA was necessary. Procedure-related embolization occurred in seven cases (12 %), which were all successfully treated by aspiration. The primary patency rate after 3 years was 55 %. Median Rutherford score decreased significantly from 5 to 0 after 36 months (p atherectomy was successfully applied to decrease the plaque burden. Results after 3 years showed a significant decrease of Rutherford score with persistent improvement of ABI and reasonable patency rate.

  16. An evaluation of flexible intramedullary nail fixation in femoral shaft fractures in paediatric age group.

    Science.gov (United States)

    Kumar, Sanjay; Roy, Sandip Kumar; Jha, Amrish Kumar; Chatterjee, Debdutta; Banerjee, Debabrata; Garg, Anant Kumar

    2011-06-01

    Sixty-two femoral shaft fractures in 60 patients treated by elastic intramedullary nailing with mean age of the patients being 9.2 years (range 5 years to 12 years) and average follow-up of 15 months (range 7 months to 60 months) are evaluated. Twenty-eight fractures were fixed with titanium elastic nail while 34 fractures were fixed with Enders nail. There were 40 midshaft fractures, 18 proximal femoral and 4 were fractures of distal third. Fracture patterns were transverse in 35, short oblique in 14 cases and 13 were spiral fractures. Mean age of union in this series was 17 weeks (range 12 weeks to 28 weeks). Ten cases had complications, 5 had nail tip irritation, 3 varus or valgus malalignment and 2 had delayed union. In this series, we did not have any non-union, refracture, limb length discrepancy or any major infection. The result demonstrates 100% union rate irrespective of the age, weight and height of the patient. Regardless of the site of fracture and their pattern, it united every time with elastic nail fixation. We did not find and mismatch in the results of fractures stabilised with titanium elastic nail with that of elastic stainless steel nail.

  17. Avascularity of the femoral head following intracapsular fracture: a comparative scintigraphic and bioptic study

    Energy Technology Data Exchange (ETDEWEB)

    Hoilund-Carlsen, P F; Widding, A; Uhrenholdt, A; Christoffersen, P; Grieff, J [Copenhagen Univ. (Denmark)

    1980-03-01

    Bioptic and scintigraphic methods of diagnosing avascular necrosis of the femoral head following intracapsular fracture of the femoral neck were compared. During operative treatment of patients, biospy samples of bone marrow were taken from the femoral head about 2 hours after the intravenous injection of sup(99m)Tc-Sn-pyrophosphate; histological examination of the biopsies were also performed. Scintigrams of the femoral head using sup(99m)Tc-pyrophosphate were performed 2 days, 7 days and 6 weeks post-operatively. The biopsies confirmed no morphological changes being apparent in the first few days. The biopsy samples indicated two groups of patients with either high or low activity in the femoral head. However, it was concluded that the use of bone-seeking radionuclides with this technique might be more reliable. Scintigraphic trends divided the patients into three groups, one with persistently normal, another with varying, and a third with decreased activity in the femoral head. It was concluded that very early scintigraphy is probably not the method of choice since the images were often difficult to interpret. For the present, assessment of the viability of the femoral head should rest upon scintigraphic examinations performed about 6 weeks or 3 months after the injury.

  18. Alterations of the blood pool in the femoral head before and after renal transplantation

    International Nuclear Information System (INIS)

    Hamaguchi, Hiroyuki; Fujioka, Mikihiro; Inoue, Shigehiro; Shibatani, Masahiko; Kubo, Toshikazu; Kubota, Takao; Ushijima, Yo; Nishimura, Tsunehiko

    2003-01-01

    The pathogenesis of idiopathic osteonecrosis of the femoral head (ION) is thought to be an ischemic event. The purpose of this study is to investigate alterations of the blood pool in the femoral head before and after renal transplantation. After renal transplantation, all patients received the same immunosuppressive therapy: corticosteroids, cyclosporin-A, and azathioprine. We performed 3-phase bone scintigraphy on 16 renal allograft recipients within 1 week before renal transplantation, and between week 4 and 9 after renal transplantation. Regions of interest (ROI) were assigned bilaterally in the femoral head, diaphysis, and soft tissue. The head-to-diaphysis ratios (HD ratios) were then calculated. Idiopathic osteonecrosis of the femoral head occurred in 2 femoral heads of 1 patient. The HD ratio before renal transplantation (mean HD±SD, 1.52±0.30) and the HD ratio after renal transplantation (1.28±0.30) were significantly different (P=0.000024). The HD ratios before and after renal transplantation were significantly different, indicating that the administration of steroids diminished the blood pool in the femoral head. A low HD ratio before renal transplantation revealed a poor blood pool in the femoral head, which may be a risk factor for ION. (author)

  19. Technique and results of femoral bifurcation endarterectomy by eversion.

    Science.gov (United States)

    Dufranc, Julie; Palcau, Laura; Heyndrickx, Maxime; Gouicem, Djelloul; Coffin, Olivier; Felisaz, Aurélien; Berger, Ludovic

    2015-03-01

    This study evaluated, in a contemporary prospective series, the safety and efficacy of femoral endarterectomy using the eversion technique and compared our results with results obtained in the literature for the standard endarterectomy with patch closure. Between 2010 and 2012, 121 patients (76% male; mean age, 68.7 years; diabetes, 28%; renal insufficiency, 20%) underwent 147 consecutive femoral bifurcation endarterectomies using the eversion technique, associating or not inflow or outflow concomitant revascularization. The indications were claudication in 89 procedures (60%) and critical limb ischemia in 58 (40%). Primary, primary assisted, and secondary patency of the femoral bifurcation, clinical improvement, limb salvage, and survival were assessed using Kaplan-Meier life-table analysis. Factors associated with those primary end-points were evaluated with univariate analysis. The technical success of eversion was of 93.2%. The 30-day mortality was 0%, and the complication rate was 8.2%; of which, half were local and benign. Median follow-up was 16 months (range, 1.6-31.2 months). Primary, primary assisted, and secondary patencies were, respectively, 93.2%, 97.2%, and 98.6% at 2 years. Primary, primary assisted, and secondary maintenance of clinical improvement were, respectively, 79.9%, 94.6%, and 98.6% at 2 years. The predictive factors for clinical degradation were clinical stage (Rutherford category 5 or 6, P = .024), platelet aggregation inhibitor treatment other than clopidogrel (P = .005), malnutrition (P = .025), and bad tibial runoff (P = .0016). A reintervention was necessary in 18.3% of limbs at 2 years: 2% involving femoral bifurcation, 6.1% inflow improvement, and 9.5% outflow improvement. The risk factors of reintervention were platelet aggregation inhibitor (other than clopidogrel, P = .049) and cancer (P = .011). Limb preservation at 2 years was 100% in the claudicant population. Limb salvage was 88.6% in the critical limb ischemia population

  20. Fluctuation Dominated Josephson Tunneling with a Scanning Tunneling Microscope

    International Nuclear Information System (INIS)

    Naaman, O.; Teizer, W.; Dynes, R. C.

    2001-01-01

    We demonstrate Josephson tunneling in vacuum tunnel junctions formed between a superconducting scanning tunneling microscope tip and a Pb film, for junction resistances in the range 50--300 k Omega. We show that the superconducting phase dynamics is dominated by thermal fluctuations, and that the Josephson current appears as a peak centered at small finite voltage. In the presence of microwave fields (f=15.0 GHz) the peak decreases in magnitude and shifts to higher voltages with increasing rf power, in agreement with theory

  1. The ISI Tunnel

    Science.gov (United States)

    1993-10-01

    DP /etc/tunnelvisa p zephyr dark -star TCP /etc/tunnelvisa p zephyr dak’star ICMP /etc/tunnelvisa p zephyr quark MDP /etc/tunnelvisa p zephyr quark ...drax-net-yp 128.9.32.2 1 route add quark -net-yp 128.9.32.3 1 route add vlsi-net-yp 128.9.32.4 1 route add darkstar-net-yp 128.9.32.3 1 route add rocky...TCP /etc/tunnel-visa p zephyr quark ICMP /etc/tunnel-visa p zephyr drax tTI)P /etc/tunnel-visa p zephyr drax TCP /etc/tunnel_visa p zephyr drax ICMP

  2. Osteochondral lesion of the bilateral femoral heads in a young athletic patient

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Eun; Ryu, Kyung Nam; Park, Ji Seon; Cho, Yoon Je [Kyung Hee University Hospital, Seoul (Korea, Republic of); Yoon, So Hee; Park, So Young; Jin, Wook [Dept. of Radiology, Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Seoul (Korea, Republic of); Lee, Kyung Ryeol [Dept. of Radiology, Jeju National University Hospital, Jeju (Korea, Republic of)

    2014-12-15

    Osteochondral lesions of the femoral head are uncommon and few studies have reported their imaging findings. Since joints are at risk of early degeneration after osteochondral damage, timely recognition is important. Osteochondral lesions of femoral head may often be necessary to differentiate from avascular necrosis. Here, we report a case of osteochondral lesions on bilateral femoral heads. This lesion manifested as subchondral cysts in initial radiographs, which led to further evaluation by computed tomography arthrography and magnetic resonance imaging, which revealed overlying cartilage defects.

  3. Resonant tunnel magnetoresistance in a double magnetic tunnel junction

    KAUST Repository

    Useinov, Arthur; Useinov, Niazbeck Kh H; Tagirov, Lenar R.; Kosel, Jü rgen

    2011-01-01

    We present quasi-classical approach to calculate a spin-dependent current and tunnel magnetoresistance (TMR) in double magnetic tunnel junctions (DMTJ) FML/I/FMW/I/FMR, where the magnetization of the middle ferromagnetic metal layer FMW can

  4. The Frank Stinchfield Award : Total Hip Arthroplasty for Femoral Neck Fracture Is Not a Typical DRG 470: A Propensity-matched Cohort Study.

    Science.gov (United States)

    Schairer, William W; Lane, Joseph M; Halsey, David A; Iorio, Richard; Padgett, Douglas E; McLawhorn, Alexander S

    2017-02-01

    Hip fractures are a major public health concern. For displaced femoral neck fractures, the needs for medical services during hospitalization and extending beyond hospital discharge after total hip arthroplasty (THA) may be different than the needs after THA performed for osteoarthritis (OA), yet these differences are largely uncharacterized, and the Medicare Severity Diagnosis-Related Groups system does not distinguish between THA performed for fracture and OA. (1) What are the differences in in-hospital and 30-day postoperative clinical outcomes for THA performed for femoral neck fracture versus OA? (2) Is a patient's fracture status, that is whether or not a patient has a femoral neck fracture, associated with differences in in-hospital and 30-day postoperative clinical outcomes after THA? The National Surgical Quality Improvement Program (NSQIP) database, which contains outcomes for surgical patients up to 30 days after discharge, was used to identify patients undergoing THA for OA and femoral neck fracture. OA and fracture cohorts were matched one-to-one using propensity scores based on age, gender, American Society of Anesthesiologists grade, and medical comorbidities. Propensity scores represented the conditional probabilities for each patient having a femoral neck fracture based on their individual characteristics, excluding their actual fracture status. Outcomes of interest included operative time, length of stay (LOS), complications, transfusion, discharge destination, and readmission. There were 42,692 patients identified (41,739 OA; 953 femoral neck fractures) with 953 patients in each group for the matched analysis. For patients with fracture, operative times were slightly longer (98 versus 92 minutes, p = 0.015), they experienced longer LOS (6 versus 4 days, p group (2.0% versus 0.2%, p = 0.002), the frequency of postoperative transfusion was not different between groups (27% versus 24%, p = 0.157). Having a femoral neck fracture versus OA was

  5. Assessment of femoral head perfusion by dynamic MR imaging

    International Nuclear Information System (INIS)

    Ochi, Ryuya; Nakano, Tetsuo; Miyazono, Kazuki; Tsurugami, Hiroshi; Fukuda, Tomohiro; Inaba, Daisuke; Takada, Koji

    2004-01-01

    We studied femoral head perfusion in 21 femoral neck fractures using dynamic MR imaging (MRI) between November 2001 and July 2002. MRI patterns divided into four groups when the results between the fractured side and unaffected side were compared. Femoral head perfusion at the fractured side was normal in Type A, about half in Type B, and absent in Type C. When perfusion at both the fractured side and unaffected side was absent, Exceptional Type was suspected. The Garden I group consisted of one Type B. The Garden II group consisted of one Type A, six Type B, one Type C, and two Exceptional Type. The Garden III group consisted of two Type B and one Type C, and the Garden IV group consisted of six Type C and one Exceptional Type. Post operations of by internal fixation confirmed the incidence of aseptic necrosis using MRI. (author)

  6. The Modernization of a Long-Focal Length Fringe-Type Laser Velocimeter

    Science.gov (United States)

    Meyers, James F.; Lee, Joseph W.; Cavone, Angelo A.; Fletcher, Mark T.

    2012-01-01

    A long-focal length laser velocimeter constructed in the early 1980's was upgraded using current technology to improve usability, reliability and future serviceability. The original, free-space optics were replaced with a state-of-the-art fiber-optic subsystem which allowed most of the optics, including the laser, to be remote from the harsh tunnel environment. General purpose high-speed digitizers were incorporated in a standard modular data acquisition system, along with custom signal processing software executed on a desktop computer, served as the replacement for the signal processors. The resulting system increased optical sensitivity with real-time signal/data processing that produced measurement precisions exceeding those of the original system. Monte Carlo simulations, along with laboratory and wind tunnel investigations were used to determine system characteristics and measurement precision.

  7. Design and Wind Tunnel Testing of a Thick, Multi-Element High-Lift Airfoil

    DEFF Research Database (Denmark)

    Zahle, Frederik; Gaunaa, Mac; Sørensen, Niels N.

    2012-01-01

    In this work a 2D CFD solver has been used to optimize the shape of a leading edge slat with a chord length of 30% of the main airfoil which was 40% thick. The airfoil configuration was subsequently tested in a wind tunnel and compared to numerical predictions. The multi-element airfoil was predi...

  8. Tunneling through landsliding zone; Jisuberi chitainai no tunnel seko

    Energy Technology Data Exchange (ETDEWEB)

    Konbu, A; Hatabu, K; Kano, T [Tekken Corp., Tokyo (Japan)

    1994-08-01

    At the new tunnel construction site of the Shirakata tunnel on the Obama line in Yamaguchi Prefecture, a landsliding occurred at about 60 meters to the upper portion obliquely to the right hand side of the shaft when the excavation progressed to about 10 meters from the starting side. The landslide caused displacement at the shaft opening and change in the supports. As a result of the re-investigation, it was confirmed that the slide face went through the tunnel cross section. The measures taken were removal of the upper soil and an adoption of the all ground fastening (AGF) method (injection type long tip fastening method) as an auxiliary construction to stop loosening of the natural ground associated with the tunnel excavation. The result was a completion of tunneling the landsliding zone without a problem. This paper reports the AGF method adopted in the above construction, together with the construction works and natural ground conditions. The AGF method is about the same as the pipe roof method with regard to the natural ground accepting mechanism and the materials used. The difference is building an improved body in a limited area in the natural ground around the steel pipes by injecting the fixing material. The use of this method caused no problems in subsidence and displacement in the surrounding ground, and completed the tunneling construction without an unusual event. 1 ref., 7 figs., 2 tabs.

  9. Finite Element Analysis of Patella Alta: A Patellofemoral Instability Model.

    Science.gov (United States)

    Watson, Nicole A; Duchman, Kyle R; Grosland, Nicole M; Bollier, Matthew J

    2017-01-01

    This study aims to provide biomechanical data on the effect of patella height in the setting of medial patellofemoral ligament (MPFL) reconstruction using finite element analysis. The study will also examine patellofemoral joint biomechanics using variable femoral insertion sites for MPFL reconstruction. A previously validated finite element knee model was modified to study patella alta and baja by translating the patella a given distance to achieve each patella height ratio. Additionally, the models were modified to study various femoral insertion sites of the MPFL (anatomic, anterior, proximal, and distal) for each patella height model, resulting in 32 unique scenarios available for investigation. In the setting of patella alta, the patellofemoral contact area decreased, resulting in a subsequent increase in maximum patellofemoral contact pressures as compared to the scenarios with normal patellar height. Additionally, patella alta resulted in decreased lateral restraining forces in the native knee scenario as well as following MPFL reconstruction. Changing femoral insertion sites had a variable effect on patellofemoral contact pressures; however, distal and anterior femoral tunnel malpositioning in the setting of patella alta resulted in grossly elevated maximum patellofemoral contact pressures as compared to other scenarios. Patella alta after MPFL reconstruction results in decreased lateral restraining forces and patellofemoral contact area and increased maximum patellofemoral contact pressures. When the femoral MPFL tunnel is malpositioned anteriorly or distally on the femur, the maximum patellofemoral contact pressures increase with severity of patella alta. When evaluating patients with patellofemoral instability, it is important to recognize patella alta as a potential aggravating factor. Failure to address patella alta in the setting of MPFL femoral tunnel malposition may result in even further increases in patellofemoral contact pressures, making it

  10. MYCOTIC FEMORAL PSEUDOANEURYSMS FROM INTRAVENOUS DRUG ABUSE

    Directory of Open Access Journals (Sweden)

    Vojko Flis

    2004-04-01

    Full Text Available Background. Parenteral drug abuse is the most common cause of infected femoral artery pseudoaneurysms (IFAP. This complication of intravenous drug abuse is not only limb threatening but can also be life threatening. The management of the IFAP is difficult and controversial. Generally speaking, ligation and excision of the pseudoaneurysm without revascularization is accepted procedure in majority of the patients. However it is not regarded as an appropriate procedure for cases where the high probability of amputation is expected from acute interruption of the femoral artery flow.Patients, methods and results. We present three cases of young (average 20 years, range 18–24 patients with IFAP, in which a primary reconstruction was performed due to absence of doppler signal over pedal arteries after ligation of common femoral artery. In two of them complications in form of haemorrhage and repeated infection developed in late postoperative period. The first one, had an excision and ligation while the second one had a reconstruction made by means of a silver impregnated dacron prosthesis. None of the patients required an amputation.Conclusions. Overall prognosis and prognosis of the reconstruction in parenteral drug abuse patients is uncertain because there is a high incidence of postoperative drug injection despite aggressive drug rehabilitation.

  11. Femoral anteversion assessment: Comparison of physical examination, gait analysis, and EOS biplanar radiography.

    Science.gov (United States)

    Westberry, David E; Wack, Linda I; Davis, Roy B; Hardin, James W

    2018-05-01

    Multiple measurement methods are available to assess transverse plane alignment of the lower extremity. This study was performed to determine the extent of correlation between femoral anteversion assessment using simultaneous biplanar radiographs and three-dimensional modeling (EOS imaging), clinical hip rotation by physical examination, and dynamic hip rotation assessed by gait analysis. Seventy-seven patients with cerebral palsy (GMFCS Level I and II) and 33 neurologically typical children with torsional abnormalities completed a comprehensive gait analysis with same day biplanar anterior-posterior and lateral radiographs and three-dimensional transverse plane assessment of femoral anteversion. Correlations were determined between physical exam of hip rotation, EOS imaging of femoral anteversion, and transverse plane hip kinematics for this retrospective review study. Linear regression analysis revealed a weak relationship between physical examination measures of hip rotation and biplanar radiographic assessment of femoral anteversion. Similarly, poor correlation was found between clinical evaluation of femoral anteversion and motion assessment of dynamic hip rotation. Correlations were better in neurologically typical children with torsional abnormalities compared to children with gait dysfunction secondary to cerebral palsy. Dynamic hip rotation cannot be predicted by physical examination measures of hip range of motion or from three-dimensional assessment of femoral anteversion derived from biplanar radiographs. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Optimization of Ecg Gating in Quantitative Femoral Angiography

    International Nuclear Information System (INIS)

    Nilsson, S.; Berglund, I.; Erikson, U.; Johansson, J.; Walldius, G.

    2003-01-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase

  13. Optimization of Ecg Gating in Quantitative Femoral Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, S.; Berglund, I.; Erikson, U. [Univ. Hospital, Uppsala (Sweden). Dept. of Oncology, Radiology and Clinical Immunology; Johansson, J.; Walldius, G. [Karolinska Hospital, Stockholm (Sweden). King Gustav V Research Inst.

    2003-09-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase.

  14. Titanium elastic nailing in pediatric femoral diaphyseal fractures

    Directory of Open Access Journals (Sweden)

    Singh Roop

    2006-01-01

    Full Text Available Background: The need for operative fixation of pediatric femoral fractures is increasingly being recognised in the present decade. The conventional traction and casting method for management of pediatric femoral fractures is giving way for the operative stabilisation of the fracture. Methods : Thirty five pediatric patients in age group 6-14 years with diaphyseal femoral fractures were stabilised with two titanium nails. Patients were followed up clinically and radiologically for two years. The final results were evaluated using the criteria of Flynn et al. Technical problems and complications associated with the procedure were also analysed. Results : Overall results observed were excellent in 25, satisfactory in 8 and poor in 2 patients. Hospital time averaged 12.30 days in the series. All the fractures healed with an average time to union of 9.6 (6-14.4 weeks. Return to school was early with an average of 7.8 weeks. The soft tissue discomfort near the knee produced by the nails ends was the most common problem encountered. Shortening was observed in three cases and restriction of knee flexion in 5 patients. There was no delayed union, infection or refractures. Per operative technical problems included failure of closed reduction in 2 cases and cork screwing of nails in one case. Conclusion : We believe that with proper operative technique and aftercare TENs may prove to be an ideal implant for pediatric femoral fracture fixation. The most of the complication associated with the procedure are infact features of inexact technique and can be eliminated by strictly adhering to the basic principles and technical aspects.

  15. Clinical application of interventional therapy for avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Han Xu; Jin Kesi; Liu Wei; Ma Jun; Shen Jianming; Aziken

    2004-01-01

    Objective: To evaluate the possibility of interventional therapy for avascular necrosis of the femoral head, with different curing methods, way of introduction and cultural heritages. Methods: Vasodilator, thrombolytics and promoting microcirculatory drug were directly injected into the feeding arteries of the avascular necrotic femoral heads, under the condition of applying the blood stoppage belt at the root of thigh with pressure before the drug injection into the femoral pronator and extension arteries. The treatment was repeated 45 d later. Urokinase 10 5 unite/d x 10 were administrated with venous infusion ipsilaterally on the 15th day after the beginning of the therapy. Imaging features and clinical symptoms were recorded and correlatively studied before and after the treament. Results: Symptoms relief especially the pain reached 100% after the treatment with various degrees of bony repair and new bone formation. Furthermore, increase caliber of feeding small arteries for femoral head and multiplicity of microvasculature, shortening of opacification time were revealed by DSA. IV stage bony change showed mild or inconspicuous. Conclusions: Interventional catheterization treatment for avascular femoral head necrosis, especially the patients of fore III stage, is safe and effective. (authors)

  16. [RESEARCH PROGRESS OF EXPERIMENTAL ANIMAL MODELS OF AVASCULAR NECROSIS OF FEMORAL HEAD].

    Science.gov (United States)

    Yu, Kaifu; Tan, Hongbo; Xu, Yongqing

    2015-12-01

    To summarize the current researches and progress on experimental animal models of avascular necrosis of the femoral head. Domestic and internation literature concerning experimental animal models of avascular necrosis of the femoral head was reviewed and analyzed. The methods to prepare the experimental animal models of avascular necrosis of the femoral head can be mainly concluded as traumatic methods (including surgical, physical, and chemical insult), and non-traumatic methods (including steroid, lipopolysaccharide, steroid combined with lipopolysaccharide, steroid combined with horse serum, etc). Each method has both merits and demerits, yet no ideal methods have been developed. There are many methods to prepare the experimental animal models of avascular necrosis of the femoral head, but proper model should be selected based on the aim of research. The establishment of ideal experimental animal models needs further research in future.

  17. Development of the tunneling junction simulation environment for scanning tunneling microscope evaluation

    International Nuclear Information System (INIS)

    Gajewski, Krzysztof; Piasecki, Tomasz; Kopiec, Daniel; Gotszalk, Teodor

    2017-01-01

    Proper configuration of scanning tunneling microscope electronics plays an important role in the atomic scale resolution surface imaging. Device evaluation in the tunneling contact between scanning tip and sample may be prone to the surface quality or mechanical disturbances. Thus the use of tunneling junction simulator makes electronics testing more reliable and increases its repeatability. Here, we present the theoretical background enabling the proper selection of electronic components circuitry used as a tunneling junction simulator. We also show how to simulate mechanics related to the piezoelectric scanner, which is applied in real experiments. Practical use of the proposed simulator and its application in metrological characterization of the developed scanning tunneling microscope is also shown. (paper)

  18. Mortality Following Periprosthetic Proximal Femoral Fractures Versus Native Hip Fractures.

    Science.gov (United States)

    Boylan, Matthew R; Riesgo, Aldo M; Paulino, Carl B; Slover, James D; Zuckerman, Joseph D; Egol, Kenneth A

    2018-04-04

    The number of periprosthetic proximal femoral fractures is expected to increase with the increasing prevalence of hip arthroplasties. While native hip fractures have a well-known association with mortality, there are currently limited data on this outcome among the subset of patients with periprosthetic proximal femoral fractures. Using the New York Statewide Planning and Research Cooperative System, we identified patients from 60 to 99 years old who were admitted to a hospital in the state with a periprosthetic proximal femoral fracture (n = 1,655) or a native hip (femoral neck or intertrochanteric) fracture (n = 97,231) between 2006 and 2014. Within the periprosthetic fracture cohort, the indication for the existing implant was not available in the data set. We used mixed-effects regression models to compare mortality at 1 and 6 months and 1 year for periprosthetic compared with native hip fractures. The risk of mortality for patients who sustained a periprosthetic proximal femoral fracture was no different from that for patients who sustained a native hip fracture at 1 month after injury (3.2% versus 4.6%; odds ratio [OR], 0.90; 95% confidence interval [CI], 0.68 to 1.19; p = 0.446), but was lower at 6 months (3.8% versus 6.5%; OR, 0.74; 95% CI, 0.57 to 0.95; p = 0.020) and 1 year (9.7% versus 15.9%; OR, 0.71; 95% CI, 0.60 to 0.85; p accounting for age and comorbidities. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  19. Clinical and Radiographic Outcomes After Submuscular Plating (SMP) of Pediatric Femoral Shaft Fractures.

    Science.gov (United States)

    Stoneback, Jason W; Carry, Patrick M; Flynn, Katherine; Pan, Zhaoxing; Sink, Ernest L; Miller, Nancy H

    2018-03-01

    To evaluate lower extremity strength and alignment among children who underwent submuscular plating (SMP). Subjects who underwent SMP for a length unstable femoral fracture returned for isokinetic strength testing ≥2 years after surgery. Extensor and flexor strength deficits (percent difference) between the operative and nonoperative limbs were evaluated. Radiographic measurements of mechanical alignment [anatomic lateral distal femoral angle (aLDFA)] and qualitative measurements (The Pediatric Outcomes Data Collection Instrument, PODCI) were obtained from all subjects. The upper 97.5% confidence interval approach to establishing clinical equivalency was utilized to compare differences in strength and alignment between the operative and nonoperative limbs. An extensor strength deficit of >19% and an aLDFA discrepancy of >5 degrees were considered to be clinically significant. The average age at surgery of the 10 subjects included in the study was 8.7 years. The hardware was placed an average of 27.9 mm from the distal femoral physis and was removed 6.4 months postsurgery. Among all subjects, the median PODCI scores were ≥97 according to all subscales. There was no significant difference in extension torque between the operative versus nonoperative limbs at 60 degrees/s (P=0.5400), 120 degrees/s (P=0.4214), or 180 degrees/s (P=0.8166). More importantly, extension strength deficits between the operative and nonoperative limbs were not clinically significant at 60 degrees/s [upper 97.5% confidence interval (CI), 10.9%], 120 degrees/s (upper 97.5% CI, 11.0%), or 180 degrees/s (upper 97.5% CI, 10.7%). The difference in aLDFA between the operative and nonoperative limb was less than the predefined clinically significant threshold of 5 degrees for all subjects. SMP achieves satisfactory clinical and functional results. In this series, extensor strength deficits and/or lower extremity malalignment were not clinically meaningful. High patient satisfaction can be

  20. Avascular necrosis of the femoral head; Chronological change of MR images

    Energy Technology Data Exchange (ETDEWEB)

    Kokubo, Takeshi; Takatori, Yoshio; Kamogawa, Morihide; Nakamura, Toshitaka; Ninomiya, Setsuo; Yoshikawa, Kohki; Itai, Yuji; Iio, Masahiro; Mitamura, Tadayuki [Tokyo Univ. (Japan). Faculty of Medicine

    1990-04-01

    T1-weighted MR images of thirty-six hips in 25 patients with avascular necrosis of the femoral head were obtained two to five times during the course of 2 to 26 months. We investigated these MR images in the light of the chronological change and compared them with plain radiographs. MR images changes in 16 femoral head; in general, the abnormal low intensity area in the femoral head reduced in extent and the internal high intensity area became smaller of disappeared. Thirteen femoral heads among them became more flattened on plain radiographs in the same period. It is noted that four different zones are defined in the femoral head after bone necrosis takes place: the dead bone marrow, the dead marrow which still contains fat, the reactive interface and the hyperemic bone marrow. In T1-weighted MR images, the dead bone marrow, the reactive interface and the hyperemic bone marrow are demonstrated as low intensity area, while the dead marrow containing fat may remain high in intensity. On the basis of this knowledge of histopathology and MR images of this disease, we suggest that reduction of the abnormal low intensity area and disappearance of the internal high intensity area on MR images can be regarded as diminution of hyperemia in the living bone marrow and loss of fat in the dead bone marrow, respectively. (author).

  1. Repair of femoral trochanteric osteotomy in the dog

    International Nuclear Information System (INIS)

    Whitelock, R.G.; Dyce, J.; Houlton, J.E.F.

    1997-01-01

    The records and radiographs of 24 dogs that underwent femoral trochanteric osteotomy repair were reviewed. Osteotomy repair was performed with either a pin and tension band wire or a lag screw technique. Significant clinical complications associated with the osteotomy were identified in one dog (4 per cent) six weeks after surgery, although abnormal radiographic changes were evident in 15 dogs (62 per cent). The method of repair did not influence healing and there were comparable radiographic complication rates. It is concluded that femoral trochanteric osteotomy is not associated with significant clinical problems, despite a high incidence of abnormal radiographic findings

  2. Case of slipped capital femoral epiphysis following radiation

    Energy Technology Data Exchange (ETDEWEB)

    Terada, Hiroshi; Usui, Hiroshi; Nakamura, Yutaka; Chiba, Masahiro; Yamaji, Shushin; Oba, Yoshihiro

    1987-06-01

    A 12-year-old boy presented with pain of the right hip joint and claudication. At the age of 7 months, the patient had received prophylactic irradiation of 30 Gy to the pelvic area including lumbar vertebrae and bilateral hip joints following extirpation of the right undescended testicle for embryonal carcinoma. Roentgenograph showed slipped capial femoral epiphysis. A review of the literature suggests that bone growth and hormonal changes in the early stage of puberty are involved, in addition to radiation damaged epiphyseal cartilage, in the pathophysiologic mechanisms of radiation induced slipped capital femoral epiphysis. (Namekawa, K.).

  3. Comparison of anatomic vs. straight femoral stem design in total hip replacement - femoral canal fill in vivo.

    Science.gov (United States)

    de Boer, Friso A; Sariali, Elhadi

    2017-05-12

    The femoral canal fill between an anatomic and a straight prosthesis design in cementless total hip arthroplasty (THA) was compared. We hypothesised that the anatomic SPS stem has higher proximal fill and lesser distal fill than the straight stem. The femoral canal fill was measured on 3 months routine postoperative x-rays at 5 levels of the stem in 50 consecutive patients, aged 35-83 years, who underwent 56 THA procedures by a single surgeon in this hospital. 22 patients received a straight design Ceramconcept Global stem, 34 patients received an anatomic design Symbios SPS stem. Both anteroposterior (AP) and lateral x-rays were combined to suggest a 3-D measurement. On the AP x-rays, the canal fill was significantly higher using the anatomic design stem at the proximal measurement levels, and was significantly higher at the distal levels using the straight stem. With the AP and lateral x-rays combined, the canal fill at the proximal levels was also significantly higher in the anatomic groups, nonsignificantly lower at the central level and significantly lower at the distal levels. In THA surgery, achieving high fill at the metaphysis of the femur and less fill at the diaphysis has been suggested to result in satisfactory outcome and high stability of the prosthesis. This study demonstrated that, compared to straight stem design, an anatomically designed stem has a significantly higher metaphyseal femoral canal fill.

  4. InN/InGaN complementary heterojunction-enhanced tunneling field-effect transistor with enhanced subthreshold swing and tunneling current

    Science.gov (United States)

    Peng, Yue; Han, Genquan; Wang, Hongjuan; Zhang, Chunfu; Liu, Yan; Wang, Yibo; Zhao, Shenglei; Zhang, Jincheng; Hao, Yue

    2016-05-01

    InN/In0.75Ga0.25N complementary heterojunction-enhanced tunneling field-effect transistors (HE-TFETs) were characterized using the numerical simulation. InN/In0.75Ga0.25N HE-TFET has an InN/In0.75Ga0.25N heterojunction located in the channel region with a distance of LT-H from the source/channel tunneling junction. We demonstrate that, for both n- and p-channel devices, HE-TFETs have a delay of onset voltage VONSET, a steeper subthreshold swing (SS), and an enhanced on-state current ION in comparison with the homo-TFETs. InN/In0.75Ga0.25N n- and p-channel HE-TFETs with a gate length LG of 25 nm and a LT-H of 5 nm achieve a 7 and 9 times ION improvement in comparison with the homo devices, respectively, at a supply voltage of 0.3 V. The performance enhancement in HE-TFETs is attributed to the modulating effect of heterojunction on band-to-band tunneling (BTBT). Because InN/In0.75Ga0.25N heterointerface shows the similar band offsets at conduction and valence bands, the InN/In0.75Ga0.25N heterojunction exhibits the improved effect on BTBT for both n- and p-channel devices. This makes InN/In0.75Ga0.25N heterojunction a promising structure for high performance complementary TFETs.

  5. Fabrication of magnetic tunnel junctions with a single-crystalline LiF tunnel barrier

    Science.gov (United States)

    Krishna Narayananellore, Sai; Doko, Naoki; Matsuo, Norihiro; Saito, Hidekazu; Yuasa, Shinji

    2018-04-01

    We fabricated Fe/LiF/Fe magnetic tunnel junctions (MTJs) by molecular beam epitaxy on a MgO(001) substrate, where LiF is an insulating tunnel barrier with the same crystal structure as MgO (rock-salt type). Crystallographical studies such as transmission electron microscopy and nanobeam electron diffraction observations revealed that the LiF tunnel barrier is single-crystalline and has a LiF(001)[100] ∥ bottom Fe(001)[110] crystal orientation, which is constructed in the same manner as MgO(001) on Fe(001). Also, the in-plane lattice mismatch between the LiF tunnel barrier and the Fe bottom electrode was estimated to be small (about 0.5%). Despite such advantages for the tunnel barrier of the MTJ, the observed tunnel magnetoresistance (MR) ratio was low (˜6% at 20 K) and showed a significant decrease with increasing temperature (˜1% at room temperature). The results imply that indirect tunneling and/or thermally excited carriers in the LiF tunnel barrier, in which the current basically is not spin-polarized, play a major role in electrical transport in the MTJ.

  6. 3D MRI findings of anterior cruciate ligament reconstruction at follow-up

    International Nuclear Information System (INIS)

    Deng Jun; Liang Biling; Chen Jianyu; Huang Suiqiao; Zhong Jinglian; Li Xiao

    2011-01-01

    Objective: To investigate the postoperative 3D MRI appearances and their evolvement patterns of ACL grafts and bone tunnels at follow-up. Methods: There were 2,6 double bundles ACL reconstructions and 16 single bundle ACL reconstructions, and a total of 56 follow-up 3D MR Imaging. MR images were reconstructed with MPR technique to evaluate grafts, bone tunnels, fixers and associated complications. Proportions of grafts with hypointensity or hyperintensity and occurrence rates of marrow edema around bone tunnels were calculated respectively among groups of different periods after operation. Results: There were 2, 4 grafts of hypointensity and 32 grafts of hyperintensity. Grafts of 2 cases were suspended with cross pins within femoral tunnels, graft of 1 case was suspended with an endobutton within the femoral tunnel, and grafts of other sites were fixed with interference screws. In the three periods as 3 months, 6 to 9 months and over 12 months after cruciate ligament reconstruction, proportions of hypointensive grafts were 20/25, 0/14 and 4/10 respectively, while proportions of hyperintensive grafts were 5/25, 14/14 and 6/10 respectively, occurrence proportions of marrow edema around bone tunnels were 54/54, 10/32 and 4/26 respectively. There was 1 tear graft, 4 tibial tunnels placed anteriorly with ACL graft impingement on the intercondylar roof, 3 femoral tunnels placed anteriorly, and 2 bone tunnels with mismatching interference screws. Conclusion: 3D MRI can accurately demonstrate the state of ACL grafts, bone tunnels, fixers and associated complications. Intensity of grafts presented a rise and reduce pattern after operation. (authors)

  7. Postoperative hemoglobin level in patients with femoral neck fracture

    OpenAIRE

    Nagra, Navraj; van Popta, Dmitri; Whiteside, Sigrid; Holt, Edward

    2018-01-01

    Objective: The aim of this study was to analyze the changes of hemoglobin levels in patients undergoing fixation for femoral neck fracture.Methods: Peroperative hemoglobin levels of patients who underwent either dynamic hip screw (DHS) fixation (n=74; mean age: 80 years) or hip hemiarthroplasty (n=104; mean age: 84 years) for femoral neck fracture was monitored.Results: There was a statistically and clinically significant mean drop of 31.1 g/L between the preoperative (D0) and postoperative D...

  8. Comparative study of construction schemes for proposed LINAC tunnel for ADSS

    International Nuclear Information System (INIS)

    Parchani, G.; Suresh, N.

    2003-01-01

    Radiation shielded structures involve architectural, structural and radiation shielding design. In order to attenuate the radiation level to the permissible limits concrete has been recognized as a most versatile radiation shielding material and is being extensively used. Concrete in addition to radiation shielding properties possesses very good mechanical properties, which enables its use as a structural member. High-energy linac lab, which will generate radiation, needs very large thickness of concrete for shielding. The length of tunnel (1.00 kM) is one of the most important factors in finalizing construction scheme. In view of this, it becomes essential to explore alternate construction schemes for such structures to optimize the cost of construction. In this paper, various alternates for the construction of proposed linac tunnel have been studied

  9. Resonant tunneling via spin-polarized barrier states in a magnetic tunnel junction

    NARCIS (Netherlands)

    Jansen, R.; Lodder, J.C.

    2000-01-01

    Resonant tunneling through states in the barrier of a magnetic tunnel junction has been analyzed theoretically for the case of a spin-polarized density of barrier states. It is shown that for highly spin-polarized barrier states, the magnetoresistance due to resonant tunneling is enhanced compared

  10. Trombose aguda de aneurisma de artéria femoral isolado: relato de caso Acute thrombosis of isolated femoral artery aneurysm: case report

    Directory of Open Access Journals (Sweden)

    André Hideo Motoki

    2008-12-01

    Full Text Available Aneurismas de artéria femoral são raros, porém são o segundo tipo mais freqüente de aneurismas periféricos, sendo o aneurisma de artéria poplítea o mais comum. Normalmente, são de etiologia aterosclerótica. As complicações deste aneurisma são representadas por embolia, trombose e, mais raramente, a rotura. O objetivo deste trabalho é relatar um caso de um paciente com 59 anos, masculino, com queixa de dor súbita em membro inferior esquerdo associado à frialdade, palidez e ausência de pulsos. O ecocolordoppler evidenciou a presença de aneurisma trombosado da artéria femoral comum. O paciente foi submetido, com sucesso, à ressecção do aneurisma, com reconstrução do leito arterial.Common femoral artery aneurysms are rare; however, they are the second most frequent type of peripheral aneurysm, popliteal artery aneurysms being the most common. They usually have atherosclerotic ethiology. The complications of this aneurysm are thromboembolism and, more rarely, rupture. This article aimed at reporting the case of a 59-year-old male patient with complaint of sudden pain in his left leg associated with coldness, paleness and absence of pulses. Color Doppler ultrasound showed a thrombosed aneurysm of the common femoral artery. The patient was successfully submitted to aneurysm resection with reconstruction of the arterial bed.

  11. Quantum tunneling time

    International Nuclear Information System (INIS)

    Wang, Z.S.; Lai, C.H.; Oh, C.H.; Kwek, L.C.

    2004-01-01

    We present a calculation of quantum tunneling time based on the transition duration of wave peak from one side of a barrier to the other. In our formulation, the tunneling time comprises a real and an imaginary part. The real part is an extension of the phase tunneling time with quantum corrections whereas the imaginary time is associated with energy derivatives of the probability amplitudes

  12. Femoral arteriographic finding in acute ergotism: Report of A Case

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, H S; Lee, K N; Cha, S B [St. Mary' s Hospital, Catholic Medical College, Seoul (Korea, Republic of)

    1971-10-15

    A case of acute ergotism with angiographic demonstration of bilateral femoral artery involvement is reported. A 27-year-old married woman was admitted because of sudden onset of severe pain in both flanks and lower legs, followed by numbness and coldness of the skin on both legs. The attack occurred after the administration of ergot tartrate as postpartum care. Femoral arteriography was performed on 10th day of illness with the Seldinger technic. The femoral arteries were generally smaller in caliber than normal. There was no definite evidence of occlusive disease. Findings were more or less symmetrical and extended to lower legs where only fine branches were visualized. The final diagnosis was diffuse vasospasm due to acute ergotism with secondary occlusion of the arteries of lower leg bilaterally.

  13. Femoral arteriographic finding in acute ergotism: Report of A Case

    International Nuclear Information System (INIS)

    Rhee, H. S.; Lee, K. N.; Cha, S. B.

    1971-01-01

    A case of acute ergotism with angiographic demonstration of bilateral femoral artery involvement is reported. A 27-year-old married woman was admitted because of sudden onset of severe pain in both flanks and lower legs, followed by numbness and coldness of the skin on both legs. The attack occurred after the administration of ergot tartrate as postpartum care. Femoral arteriography was performed on 10th day of illness with the Seldinger technic. The femoral arteries were generally smaller in caliber than normal. There was no definite evidence of occlusive disease. Findings were more or less symmetrical and extended to lower legs where only fine branches were visualized. The final diagnosis was diffuse vasospasm due to acute ergotism with secondary occlusion of the arteries of lower leg bilaterally

  14. Postoperative hemoglobin level in patients with femoral neck fracture.

    Science.gov (United States)

    Nagra, Navraj S; Van Popta, Dmitri; Whiteside, Sigrid; Holt, Edward M

    2016-01-01

    The aim of this study was to analyze the changes of hemoglobin levels in patients undergoing fixation for femoral neck fracture. Peroperative hemoglobin levels of patients who underwent either dynamic hip screw (DHS) fixation (n=74; mean age: 80 years) or hip hemiarthroplasty (n=104; mean age: 84 years) for femoral neck fracture was monitored. There was a statistically and clinically significant mean drop of 31.1 g/L between the preoperative (D0) and postoperative Day 5 Hb levels (pmeasurement, DHS patients had lower hemoglobin values over hemiarthroplasty patients (p=0.046). The decrease in hemoglobin in the first 24-hour postoperative period (D0 to Day 1) is an underestimation of the ultimate lowest value in hemoglobin found at Day 2. Relying on the Day 1 hemoglobin level could be detrimental to patient care. We propose a method of predicting patients likely to be transfused and recommend a protocol for patients undergoing femoral neck fracture surgery to standardize postoperative hemoglobin monitoring.

  15. Does femoral offset recover and affect the functional outcome of patients with displaced femoral neck fracture following hemiarthroplasty?

    Science.gov (United States)

    Ji, Hyung-Min; Won, Seok-Hyung; Han, Jun; Won, Ye-Yeon

    2017-06-01

    Restoring preoperative horizontal femoral offset (FO) promised good functional outcome in patients receiving total hip arthroplasty. However, relatively little was known regarding the clinical relevance of restoring the offset in patients with bipolar hemiarthroplasty to treat displaced femoral neck fracture. Therefore, the objective of this study was to evaluate postoperative FO accurately and verify its relation with functional outcome. One hundred elderly patients who received bipolar hemiarthroplasty to treat displaced femoral neck fracture were identified. Preoperative CT scanning of contralateral hip joint and reconstruction of images led to rotation-free FO. By referencing postoperative implant specification and comparing to measured values in Picture Archive and Communication System, rotation-free postoperative FO and the amount of change were acquired. Postoperative Harris Hip Score (HHS) and Modified Barthel Index (MBI) were evaluated to measure functional outcome at 12-month after the surgery. Patients with significant FO change were identified. Multiple regression analysis was conducted to determine if the FO change might independently affect the outcome regardless of confounding factors. The mean preoperative offset was 37.4±2.5 increased by 12.7±9.6% after the surgery. Only 25.0% of postoperative offset after hemiarthroplasty was changed within ±5% of preoperative offset. A total of 45.0% of postoperative offset changed within ±10% while 77.0% of postoperative offset changed within ±20%. 23% of patients whose FO changed more than 20% showed significantly worse outcome score than the patients whose FO change remained within ±20% of initial value. Mean MBI and HHS were negatively correlated with FO change. After adjusting for confounding factors, significant correlation remained between modification of FO and MBI, but not between FO change and HHS (B=4.576; β=0.235; 95% confidence interval of B: 0.534 to 8.135). FO was not properly restored in 23

  16. Matrix effect on hydrogen-atom tunneling of organic molecules in cryogenic solids

    International Nuclear Information System (INIS)

    Ichikawa, Tsuneki

    2000-01-01

    tunneling of hydrogen atoms. Since the tunneling rate depends not on the peak height of the potential barrier but on the area of the barrier, the restriction of molecular motion by rigid matrices causes the retardation of the hydrogen-atom tunneling. The steric hindrance increases with increasing number and length of alkyl chains attached to a carbon atom to be hydrogen-abstracted. The Penultimate secondary carbon therefore shows the highest reaction rate. (author)

  17. Nontraumatic femoral head necrosis. Classification of bone scintigraphic findings and diagnostic value of SPECT following planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Minoshima, Satoshi; Uchida, Yoshitaka; Anzai, Yoshimi; Uno, Kimiichi; Arimizu, Noboru [Chiba Univ. (Japan). School of Medicine

    1994-09-01

    This study was conducted to determine bone scintigraphic findings in nontraumatic femoral head avascular necrosis and diagnostic value of SPECT imaging following a conventional planar imaging. Forty-three femoral heads in twenty-six cases with idiopathic femoral head necrosis (n=2), systemic lupus erythematosus (n=22), aplastic anemia (n=1), and renal transplantation (n=1) were studied. The diagnosis for femoral head necrosis was based on magnetic resonance imaging as well as other diagnostic studies in all cases. Scintigraphic findings of planar and SPECT images were classified into six categories: normal (N); cold or decrease (C); partial increase with cold or decrease (PH+C); ring-like increase with a cold center (RH+C); partial increase (PH); diffuse and/or irregular increase (DH). Avascular necrosis was confirmed in twenty-four femoral heads, in which planar and SPECT images showed scintigraphic findings of N (n=3, 2), C (n=1, 3), PH+C (n=2, 8), RH+C (n=2, 3), PH (n=9, 2), and DH (n=7, 6), respectively. Femoral heads without avascular necrosis demonstrated planar and SPECT findings of N (n=16, 12), C (n=0, 6), and DH (n=3, 1), respectively. When considering C, PH+C, and RH+C as diagnostic findings for avascular necrosis, sensitivities of planar and SPECT images were 21% and 58%, and specificities were 100% and 68%, respectively. In nineteen femoral heads with normal planar findings (N), SPECT correctly identified avascular necrosis in two femoral heads and misidentified six normal femoral heads as avascular necrosis. In nineteen femoral heads with nondiagnostic abnormalities (PH, DH), SPECT correctly identified avascular necrosis in seven femoral heads and showed no false positive. Diagnostic planar findings in five femoral heads were concordant with SPECT diagnosis. These results indicate that SPECT imaging is most valuable when planar images show nondiagnostic abnormalities based on the proposed classification of scintigraphic findings. (author).

  18. Nontraumatic femoral head necrosis. Classification of bone scintigraphic findings and diagnostic value of SPECT following planar imaging

    International Nuclear Information System (INIS)

    Minoshima, Satoshi; Uchida, Yoshitaka; Anzai, Yoshimi; Uno, Kimiichi; Arimizu, Noboru

    1994-01-01

    This study was conducted to determine bone scintigraphic findings in nontraumatic femoral head avascular necrosis and diagnostic value of SPECT imaging following a conventional planar imaging. Forty-three femoral heads in twenty-six cases with idiopathic femoral head necrosis (n=2), systemic lupus erythematosus (n=22), aplastic anemia (n=1), and renal transplantation (n=1) were studied. The diagnosis for femoral head necrosis was based on magnetic resonance imaging as well as other diagnostic studies in all cases. Scintigraphic findings of planar and SPECT images were classified into six categories: normal (N); cold or decrease (C); partial increase with cold or decrease (PH+C); ring-like increase with a cold center (RH+C); partial increase (PH); diffuse and/or irregular increase (DH). Avascular necrosis was confirmed in twenty-four femoral heads, in which planar and SPECT images showed scintigraphic findings of N (n=3, 2), C (n=1, 3), PH+C (n=2, 8), RH+C (n=2, 3), PH (n=9, 2), and DH (n=7, 6), respectively. Femoral heads without avascular necrosis demonstrated planar and SPECT findings of N (n=16, 12), C (n=0, 6), and DH (n=3, 1), respectively. When considering C, PH+C, and RH+C as diagnostic findings for avascular necrosis, sensitivities of planar and SPECT images were 21% and 58%, and specificities were 100% and 68%, respectively. In nineteen femoral heads with normal planar findings (N), SPECT correctly identified avascular necrosis in two femoral heads and misidentified six normal femoral heads as avascular necrosis. In nineteen femoral heads with nondiagnostic abnormalities (PH, DH), SPECT correctly identified avascular necrosis in seven femoral heads and showed no false positive. Diagnostic planar findings in five femoral heads were concordant with SPECT diagnosis. These results indicate that SPECT imaging is most valuable when planar images show nondiagnostic abnormalities based on the proposed classification of scintigraphic findings. (author)

  19. First-principles investigation of quantum transport in GeP3 nanoribbon-based tunneling junctions

    Science.gov (United States)

    Wang, Qiang; Li, Jian-Wei; Wang, Bin; Nie, Yi-Hang

    2018-06-01

    Two-dimensional (2D) GeP3 has recently been theoretically proposed as a new low-dimensional material [ Nano Lett. 17(3), 1833 (2017)]. In this manuscript, we propose a first-principles calculation to investigate the quantum transport properties of several GeP3 nanoribbon-based atomic tunneling junctions. Numerical results indicate that monolayer GeP3 nanoribbons show semiconducting behavior, whereas trilayer GeP3 nanoribbons express metallic behavior owing to the strong interaction between each of the layers. This behavior is in accordance with that proposed in two-dimensional GeP3 layers. The transmission coefficient T( E) of tunneling junctions is sensitive to the connecting formation between the central monolayer GeP3 nanoribbon and the trilayer GeP3 nanoribbon at both ends. The T( E) value of the bottom-connecting tunneling junction is considerably larger than those of the middle-connecting and top-connecting ones. With increases in gate voltage, the conductances increase for the bottom-connecting and middle-connecting tunneling junctions, but decrease for the top-connecting tunneling junctions. In addition, the conductance decreases exponentially with respect to the length of the central monolayer GeP3 nanoribbon for all the tunneling junctions. I-V curves show approximately linear behavior for the bottom-connecting and middle-connecting structures, but exhibit negative differential resistance for the top-connecting structures. The physics of each phenomenon is analyzed in detail.

  20. Measuring fire size in tunnels

    International Nuclear Information System (INIS)

    Guo, Xiaoping; Zhang, Qihui

    2013-01-01

    A new measure of fire size Q′ has been introduced in longitudinally ventilated tunnel as the ratio of flame height to the height of tunnel. The analysis in this article has shown that Q′ controls both the critical velocity and the maximum ceiling temperature in the tunnel. Before the fire flame reaches tunnel ceiling (Q′ 1.0), Fr approaches a constant value. This is also a well-known phenomenon in large tunnel fires. Tunnel ceiling temperature shows the opposite trend. Before the fire flame reaches the ceiling, it increases very slowly with the fire size. Once the flame has hit the ceiling of tunnel, temperature rises rapidly with Q′. The good agreement between the current prediction and three different sets of experimental data has demonstrated that the theory has correctly modelled the relation among the heat release rate of fire, ventilation flow and the height of tunnel. From design point of view, the theoretical maximum of critical velocity for a given tunnel can help to prevent oversized ventilation system. -- Highlights: • Fire sizing is an important safety measure in tunnel design. • New measure of fire size a function of HRR of fire, tunnel height and ventilation. • The measure can identify large and small fires. • The characteristics of different fire are consistent with observation in real fires