WorldWideScience

Sample records for femoral material properties

  1. Mechanical properties of femoral trabecular bone in dogs

    Directory of Open Access Journals (Sweden)

    Nolte Ingo

    2005-03-01

    Full Text Available Abstract Background Studying mechanical properties of canine trabecular bone is important for a better understanding of fracture mechanics or bone disorders and is also needed for numerical simulation of canine femora. No detailed data about elastic moduli and degrees of anisotropy of canine femoral trabecular bone has been published so far, hence the purpose of this study was to measure the elastic modulus of trabecular bone in canine femoral heads by ultrasound testing and to assess whether assuming isotropy of the cancellous bone in femoral heads in dogs is a valid simplification. Methods From 8 euthanized dogs, both femora were obtained and cubic specimens were cut from the centre of the femoral head which were oriented along the main pressure and tension trajectories. The specimens were tested using a 100 MHz ultrasound transducer in all three orthogonal directions. The directional elastic moduli of trabecular bone tissue and degrees of anisotropy were calculated. Results The elastic modulus along principal bone trajectories was found to be 11.2 GPa ± 0.4, 10.5 ± 2.1 GPa and 10.5 ± 1.8 GPa, respectively. The mean density of the specimens was 1.40 ± 0.09 g/cm3. The degrees of anisotropy revealed a significant inverse relationship with specimen densities. No significant differences were found between the elastic moduli in x, y and z directions, suggesting an effective isotropy of trabecular bone tissue in canine femoral heads. Discussion This study presents detailed data about elastic moduli of trabecular bone tissue obtained from canine femoral heads. Limitations of the study are the relatively small number of animals investigated and the measurement of whole specimen densities instead of trabecular bone densities which might lead to an underestimation of Young's moduli. Publications on elastic moduli of trabecular bone tissue present results that are similar to our data. Conclusion This study provides data about directional elastic

  2. Quasi-linear viscoelastic properties of the human medial patello-femoral ligament.

    Science.gov (United States)

    Criscenti, G; De Maria, C; Sebastiani, E; Tei, M; Placella, G; Speziali, A; Vozzi, G; Cerulli, G

    2015-12-16

    The evaluation of viscoelastic properties of human medial patello-femoral ligament is fundamental to understand its physiological function and contribution as stabilizer for the selection of the methods of repair and reconstruction and for the development of scaffolds with adequate mechanical properties. In this work, 12 human specimens were tested to evaluate the time- and history-dependent non linear viscoelastic properties of human medial patello-femoral ligament using the quasi-linear viscoelastic (QLV) theory formulated by Fung et al. (1972) and modified by Abramowitch and Woo (2004). The five constant of the QLV theory, used to describe the instantaneous elastic response and the reduced relaxation function on stress relaxation experiments, were successfully evaluated. It was found that the constant A was 1.21±0.96MPa and the dimensionless constant B was 26.03±4.16. The magnitude of viscous response, the constant C, was 0.11±0.02 and the initial and late relaxation time constants τ1 and τ2 were 6.32±1.76s and 903.47±504.73s respectively. The total stress relaxation was 32.7±4.7%. To validate our results, the obtained constants were used to evaluate peak stresses from a cyclic stress relaxation test on three different specimens. The theoretically predicted values fit the experimental ones demonstrating that the QLV theory could be used to evaluate the viscoelastic properties of the human medial patello-femoral ligament. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Femoral Cortical Bone Mineral Density and Biomechanical Properties in Sheep Consuming an Acidifying Diet

    Directory of Open Access Journals (Sweden)

    Eileen S. Hackett

    2009-01-01

    Full Text Available Dietary acidity is a likely contributor to the development of osteoporosis. Dietary acidosis in an ovine model has effects on trabecular bone that have been previously shown to mimic human osteoporosis. Effects on cortical bone using this model have not been investigated. The objective of this study was to examine the effects of dietary acidosis on cortical bone mineral density and material properties. Skeletally mature ovariectomized (OVX sheep consumed either a normal diet (ND or a metabolic acidosis diet (MA for 6 or 12 months. Whole femoral and cortical bone beam BMD was determined using dual energy x-ray absorptiometry (DEXA. Beams were then subjected to three point flexure monotonically to failure to determine strength and modulus and then ashed to determine percent mineralization. Femoral BMD in adult OVX ND 6 mo sheep was significantly greater than those in the non-OVX ND group. The BMD in the MA groups was lower than the control non-OVX ND group. Cortical beams had significantly decreased modulus in all MA and OVX groups when compared with the non-OVX ND group and a tendency towards decreased strength in all groups with significance only in the OVX ND 6 mo sheep. Percent mineralization increased in MA and OVX groups when compared to the non-OVX ND group and was significantly increased in the OVX ND 6 mo and OVX MA 12 mo groups. A significant correlation was seen between BMD of the beam and breaking strength and modulus. Dietary acidity impacts cortical bone and results in reduced material properties that may contribute to failure.

  4. Healing of experimental femoral defects in rats after implantation of collagen-calcium phosphate biocomposites

    Directory of Open Access Journals (Sweden)

    O. V. Korenkov

    2017-06-01

    Full Text Available The aim of this study was to investigate the healing process of experimental defects of the femoral shaft diaphysis of rats after implantation of osteoplastic material Collapan into its cavity. In experi-mental animals, a perforated defect with diameter of 2.5 mm was created in the medullary canal of the femoral shaft and filled with osteoplastic material Collapan. In control rats, the defect was left un-filled. The bone fragments were examined on the 15th and 30th day by light microscopy morphometry and scanning electron microscopy. It was found that application of osteoplastic material Collapan in the femoral diaphysis defect optimised reparative osteogenesis, showed high biocompatibility, osteo-conductive properties, resorption ability and good integration with tissue-specific structures of the regenerate

  5. Micromechanical properties of canine femoral articular cartilage following multiple freeze-thaw cycles.

    Science.gov (United States)

    Peters, Abby E; Comerford, Eithne J; Macaulay, Sophie; Bates, Karl T; Akhtar, Riaz

    2017-07-01

    Tissue material properties are crucial to understanding their mechanical function, both in healthy and diseased states. However, in certain circumstances logistical limitations can prevent testing on fresh samples necessitating one or more freeze-thaw cycles. To date, the nature and extent to which the material properties of articular cartilage are altered by repetitive freezing have not been explored. Therefore, the aim of this study is to quantify how articular cartilage mechanical properties, measured by nanoindentation, are affected by multiple freeze-thaw cycles. Canine cartilage plugs (n = 11) from medial and lateral femoral condyles were submerged in phosphate buffered saline, stored at 3-5°C and tested using nanoindentation within 12h. Samples were then frozen at -20°C and later thawed at 3-5°C for 3h before material properties were re-tested and samples re-frozen under the same conditions. This process was repeated for all 11 samples over three freeze-thaw cycles. Overall mean and standard deviation of shear storage modulus decreased from 1.76 ± 0.78 to 1.21 ± 0.77MPa (p = 0.91), shear loss modulus from 0.42 ± 0.19 to 0.39 ± 0.17MPa (p=0.70) and elastic modulus from 5.13 ± 2.28 to 3.52 ± 2.24MPa (p = 0.20) between fresh and three freeze-thaw cycles respectively. The loss factor increased from 0.31 ± 0.38 to 0.71 ± 1.40 (p = 0.18) between fresh and three freeze-thaw cycles. Inter-sample variability spanned as much as 10.47MPa across freezing cycles and this high-level of biological variability across samples likely explains why overall mean "whole-joint" trends do not reach statistical significance across the storage conditions tested. As a result multiple freeze-thaw cycles cannot be explicitly or statistically linked to mechanical changes within the cartilage. However, the changes in material properties observed herein may be sufficient in magnitude to impact on a variety of clinical and scientific studies of cartilage, and should be considered

  6. Multicriteria Decision Analysis in Improving Quality of Design in Femoral Component of Knee Prostheses: Influence of Interface Geometry and Material

    Directory of Open Access Journals (Sweden)

    Ali Jahan

    2015-01-01

    Full Text Available Knee prostheses as medical products require careful application of quality and design tool to ensure the best performance. Therefore, quality function deployment (QFD was proposed as a quality tool to systematically integrate consumer’s expectation to perceived needs by medical and design team and to explicitly address the translation of customer needs into engineering characteristics. In this study, full factorial design of experiment (DOE method was accompanied by finite element analysis (FEA to evaluate the effect of inner contours of femoral component on mechanical stability of the implant and biomechanical stresses within the implant components and adjacent bone areas with preservation of the outer contours for standard Co-Cr alloy and a promising functionally graded material (FGM. The ANOVA revealed that the inner shape of femoral component influenced the performance measures in which the angle between the distal and anterior cuts and the angle between the distal and posterior cuts were greatly influential. In the final ranking of alternatives, using multicriteria decision analysis (MCDA, the designs with FGM was ranked first over the Co-Cr femoral component, but the original design with Co-Cr material was not the best choice femoral component, among the top ranked design with the same material.

  7. Microstructures and properties of cancellous bone of avascular necrosis of femoral heads

    Science.gov (United States)

    Yao, Xuefeng; Wang, Peng; Dai, Ruchun; Yeh, Hsien Yang

    2010-03-01

    The aim of this study is to investigate microscopic structure and characterize cancellous bone of avascular necrosis of the femoral head (ANFH). The rabbit model of the ANFH is established. The histopathologic features are studied successfully. The differences between the steroid-injection group (S.G.) and the controlled group (C.G.) are examined, including the weight of rabbits, the hematological examination and the three-dimensional structures. It is found that the plasma levels of cholesterol (CHO), high-density lipoprotein (HDL) and low-density lipoprotein (LDL) in S.G. are lower than those in C.G. when the triglyceride (TG) increased in the S.G.; but the bone mineral content (BMC) and the structural model index (SMI) of the organ and tissue decreased significantly in S.G. Three-dimensional structures of the femoral head are obtained using micro-computed tomography (CT) scanning and the mechanical model is established to analyze the influences of these structural changes on the mechanical properties of the cancellous bone.

  8. PEEK-OPTIMA? as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study

    OpenAIRE

    Cowie, Raelene M; Briscoe, Adam; Fisher, John; Jennings, Louise M

    2016-01-01

    PEEK-OPTIMA™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA™ femoral components art...

  9. The 5-year Results of an Oxidized Zirconium Femoral Component for TKA

    Science.gov (United States)

    Innocenti, Massimo; Carulli, Christian; Matassi, Fabrizio; Villano, Marco

    2009-01-01

    Osteolysis secondary to polyethylene wear is one of the major factors limiting long-term performance of TKA. Oxidized zirconium is a new material that combines the strength of a metal with the wear properties of a ceramic. It remains unknown whether implants with a zirconium femoral component can be used safely in TKA. To answer that question, we reviewed, at a minimum of 5 years, the clinical outcome and survivorship of a ceramic-surfaced oxidized zirconium femoral component implanted during 98 primary TKAs between April 2001 and December 2003. Survivorship was 98.7% at 7 years postoperatively. No revision was necessary and only one component failed because of aseptic loosening. Mean Knee Society score improved from 36 to 89. No adverse events were observed clinically or radiologically. These results justify pursuing the use of oxidized zirconium as an alternative bearing surface for a femoral component in TKA. Level of Evidence: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence. PMID:19798541

  10. Mechanical Characterization of Femoral Cartilage Under Unicompartimental Osteoarthritis

    OpenAIRE

    Vidal-Lesso, A.; Ledesma-Orozco, E.; Daza-Benítez, L.; Lesso-Arroyo, R.

    2014-01-01

    The aim of this study was to determine the mechanical properties and thickness of articular cartilage in the unaffected femoral regions in cases of unicompartimental osteoarthritis on the knees. The specimens were tested using a 3mm plane-ended cylindrical indenter and a displacement of 0.5mm was applied at specific points in seven femoral knee cartilages with unicompartimental osteoarthritis. The thickness, stiffness, elastic modulus, shear modulus and bulk modulus were obtained. These prope...

  11. Radiographic femoral varus measurement is affected unpredictably by femoral rotation

    DEFF Research Database (Denmark)

    Miles, James Edward

    Radiographic measurements of femoral varus are used to determine if intervention to correct femoral deformity is required, and to calculate the required correction. The varus angle is defined as the angle between the proximal femoral long axis (PFLA) and an axis tangential to the distal femoral...... and externally by 5° and 10° using plastic wedges. Accuracy of rotation was within +1°. Digital radiographs were obtained at each position. Varus angles were measured using ImageJ, employing two definitions of PFLA. Mean varus angles increased with 10° of either internal or external rotation with both PFLA...... rotation angles. The effect of rotation on varus angle measurements in these femoral specimens contradicts a previous report using CT. The most probable explanation is the difference in femoral positioning: the CT study used a slightly elevated position compared to that in this study, resulting in better...

  12. Articulation of Native Cartilage Against Different Femoral Component Materials. Oxidized Zirconium Damages Cartilage Less Than Cobalt-Chrome.

    Science.gov (United States)

    Vanlommel, Jan; De Corte, Ronny; Luyckx, Jean Philippe; Anderson, Melissa; Labey, Luc; Bellemans, Johan

    2017-01-01

    Oxidized zirconium (OxZr) is produced by thermally driven oxidization creating an oxidized surface with the properties of a ceramic at the top of the Zr metal substrate. OxZr is much harder and has a lower coefficient of friction than cobalt-chrome (CoCr), both leading to better wear characteristics. We evaluated and compared damage to the cartilage of porcine patella plugs, articulating against OxZr vs CoCr. Our hypothesis was that, owing to its better wear properties, OxZr would damage cartilage less than CoCr. If this is true, OxZr might be a better material for the femoral component during total knee arthroplasty if the patella is not resurfaced. Twenty-one plugs from porcine patellae were prepared and tested in a reciprocating pin-on-disk machine while lubricated with bovine serum and under a constant load. Three different configurations were tested: cartilage-cartilage as the control group, cartilage-OxZr, and cartilage-CoCr. Macroscopic appearance, cartilage thickness, and the modified Mankin score were evaluated after 400,000 wear cycles. The control group showed statistically significant less damage than plugs articulating against both other materials. Cartilage plugs articulating against OxZr were statistically significantly less damaged than those articulating against CoCr. Although replacing cartilage by an implant always leads to deterioration of the cartilage counterface, OxZr results in less damage than CoCr. The use of OxZr might thus be preferable to CoCr in case of total knee arthroplasty without patella resurfacing. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Comparative study of material loss at the taper interface in retrieved metal-on-polyethylene and metal-on-metal femoral components from a single manufacturer.

    Science.gov (United States)

    Bills, Paul; Racasan, Radu; Bhattacharya, Saugatta; Blunt, Liam; Isaac, Graham

    2017-08-01

    There have been a number of reports on the occurrence of taper corrosion and/or fretting and some have speculated on a link to the occurrence of adverse local tissue reaction specifically in relation to total hip replacement which have a metal-on-metal bearing. As such a study was carried out to compare the magnitude of material loss at the taper in a series of retrieved femoral heads used in metal-on-polyethylene bearings with that in a series of retrieved heads used in metal-on-metal bearings. A total of 36 metal-on-polyethylene and 21 metal-on-metal femoral components were included in the study all of which were received from a customer complaint database. Furthermore, a total of nine as-manufactured femoral components were included to provide a baseline for characterisation. All taper surfaces were assessed using an established corrosion scoring method and measurements were taken of the female taper surface using a contact profilometry. In the case of metal-on-metal components, the bearing wear was also assessed using coordinate metrology to determine whether or not there was a relationship between bearing and taper material loss in these cases. The study found that in this cohort the median value of metal-on-polyethylene taper loss was 1.25 mm 3 with the consequent median value for metal-on-metal taper loss being 1.75 mm 3 . This study also suggests that manufacturing form can result in an apparent loss of material from the taper surface determined to have a median value of 0.59 mm 3 . Therefore, it is clear that form variability is a significant confounding factor in the measurement of material loss from the tapers of femoral heads retrieved following revision surgery.

  14. Wear resistance of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted carbon fiber reinforced poly(ether ether ketone) liners against metal and ceramic femoral heads.

    Science.gov (United States)

    Yamane, Shihori; Kyomoto, Masayuki; Moro, Toru; Hashimoto, Masami; Takatori, Yoshio; Tanaka, Sakae; Ishihara, Kazuhiko

    2018-04-01

    Younger, active patients who undergo total hip arthroplasty (THA) have increasing needs for wider range of motion and improved stability of the joint. Therefore, bearing materials having not only higher wear resistance but also mechanical strength are required. Carbon fiber-reinforced poly(ether ether ketone) (CFR-PEEK) is known as a super engineering plastic that has great mechanical strength. In this study, we focused on poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC)-grafted CFR-PEEK and investigated the effects of PMPC grafting and the femoral heads materials on the wear properties of CFR-PEEK liners. Compared with untreated CFR-PEEK, the PMPC-grafted CFR-PEEK surface revealed higher wettability and lower friction properties under aqueous circumstances. In the hip simulator wear test, wear particles generated from the PMPC-grafted CFR-PEEK liners were fewer than those of the untreated CFR-PEEK liners. There were no significant differences in the size and the morphology of the wear particles between the differences of PMPC-grafting and the counter femoral heads. Zirconia-toughened alumina (ZTA) femoral heads had significantly smoother surfaces compared to cobalt-chromium-molybdenum alloy femoral heads after the hip simulator test. Thus, we conclude that the bearing combination of the PMPC-grafted CFR-PEEK liner and ZTA head is expected to be a lifelong bearing interface in THA. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1028-1037, 2018. © 2017 Wiley Periodicals, Inc.

  15. Factors that influence femoral neck length. Analysis of 1543 patients with advanced osteoarthritis of the hip

    NARCIS (Netherlands)

    Prins, Wybren; Kollen, Boudewijn J.; Ettema, Harmen B.; Verheyen, Cees C. P. M.

    2013-01-01

    Background and purpose: There is little known about the relationship between patient characteristic and the variance in geometrical properties of the femoral neck. The length of the femoral neck is relevant when considering a femoral neck preserving hip replacement. Based on surgical experience we

  16. Differences in Femoral Geometry and Structure Due to Immobilization

    Science.gov (United States)

    Kiratli, Beatrice Jenny; Yamada, M.; Smith, A.; Marcus, R. M.; Arnaud, S.; vanderMeulen, M. C. H.; Hargens, Alan R. (Technical Monitor)

    1996-01-01

    Reduction in bone mass of the lower extremity is well documented in individuals with paralysis resulting from spinal cord injury (SCI). The consequent osteopenia leads to elevated fracture risk with fractures occurring more commonly in the femoral shaft and supracondylar regions than the hip. A model has recently been described to estimate geometry and structure of the femoral midshaft from whole body scans by dual X-ray absorptiometry (DXA). Increases in femoral geometric and structural properties during growth were primarily related to mechanical loading as reflected by body mass. In this study, we investigate the relationship between body mass and femoral geometry and structure in adults with normal habitual mechanical loading patterns and those with severely reduced loading. The subjects were 78 ambulatory men (aged 20-72 yrs) and 113 men with complete paralysis from SCI of more than 4 years duration (aged 21 73 yrs). Subregional analysis was performed on DXA whole body scans to obtain bone mineral content (BMC, g), cortical thickness (cm), crosssectional moment of inertia (CSMI, cm4), and section modulus (cm3) of the femoral midshaft. All measured bone variables were significantly lower in SCI compared with ambulatory subjects: -29% (BMC), -33% (cortical thickness), -23% (CSMI), and -22% (section modulus) while body mass was not significantly different. However, the associations between body mass and bone properties were notably different; r2 values were higher for ambulatory than SCI subjects in regressions of body mass on BMC (0.48 vs 0.20), CSMI (0.59 vs 0.32), and section modulus (0.59 vs 0.31). No association was seen between body mass and cortical thickness for either group. The greatest difference between groups is in the femoral cortex, consistent with reduced bone mass via endosteal expansion. The relatively lesser difference in geometric and structural properties implies that there is less effect on mechanical integrity than would be expected from

  17. Posterior Femoral Single Limb Osteotomy for the Removal of Well-Fixed Modular Femoral Neck Components

    Directory of Open Access Journals (Sweden)

    Keith A Fehring

    2017-07-01

    Full Text Available Modular neck femoral components were introduced to optimize femoral neck anteversion, leg length, offset, and stability in total hip arthroplasty. However, concerns have been raised in recent years regarding early failure of these implants due to corrosion, pseudotumor, as well as fracture of the modular neck. Removing modular neck femoral implants is challenging as removal of the modular femoral neck leaves a proximally coated femoral stem level with the proximal bone of the femoral neck. We describe a posterior femoral single limb osteotomy  (posterior cut of an extended trochanteric osteotomy for the removal of a modular neck femoral component.

  18. Femoral nerve damage (image)

    Science.gov (United States)

    The femoral nerve is located in the leg and supplies the muscles that assist help straighten the leg. It supplies sensation ... leg. One risk of damage to the femoral nerve is pelvic fracture. Symptoms of femoral nerve damage ...

  19. Femoral rotation unpredictably affects radiographic anatomical lateral distal femoral angle measurements

    DEFF Research Database (Denmark)

    Miles, James Edward

    2016-01-01

    Objective: To describe the effects of internal and external femoral rotation on radiographic measurements of the anatomical lateral distal femoral angle (a-LDFA) using two methods for defining the anatomical proximal femoral axis (a-PFA). Methods: Digital radiographs were obtained of 14 right...... femora at five degree intervals from 10° external rotation to 10° internal rotation. Using freely available software, a-LDFA measurements were made using two different a-PFA by a single observer on one occasion. Results: Mean a-LDFA was significantly greater at 10° external rotation than at any other...... rotation. The response of individual femora to rotation was unpredictable, although fairly stable within ±5° of zero rotation. Mean a-LDFA for the two a-PFA methods differed by 1.5°, but were otherwise similarly affected by femoral rotation. Clinical significance: If zero femoral elevation can be achieved...

  20. Femoral head allograft disinfection system using moderate heat

    International Nuclear Information System (INIS)

    Knaepler, H.; Von Garrel, T.

    1999-01-01

    The employment of a reliable thermal viral inactivation process, which minimally manipulates tissues, for surgically retrieved femoral head allografts addresses the increased concerns with virus transmissibility while minimizing the loss of biological properties. The newest European and German surgical bone banking guidelines have incorporated the use of independently validated then-nal viral inactivation methods in place of repeat serological testing of donor. Our investigations have shown that heat treatment at 80 degree C for a minimum of 10 minutes provides safe, good quality cancellous bone allografts and increases the cost-effectiveness and simplicity of managing a hospital frozen femoral head bone bank. Human femoral head centers were contaminated with different vegetative bacterial and viral suspensions. A core temperature of 80 degree C for 10 minutes was sufficient to fully inactivate 3 x 106 ml Staphylococcus aureus and Streptococcus faecalis, and >5 loglo steps of cytomeglia (herpes group), polio (enterovirus), and yellow fever (arbovirus) viruses. A one hour treatment in a water bath set at 80 degree sufficient to fully inactivate E. coli, proteus vulgaris, and Pseudomonas aerog. vegetative suspensions; 20 minutes was sufficient to fully inactivate the D antigen (rhesus factor) but had no effect on A or B antigens. Several biomechanical and biological properties of bone following a one hour treatment in a water bath set at 80 degree C were investigated. Employing compression and tension tests, 80 degree C treated human and porcine cancellous bone blocks showed reductions in properties ranging from 8-19% compared to untreated control groups. Osteointegration at 3 months following treatment of explanted and then reimplanted autograft rat diaphyseal segment was 15% less than untreated controls. Subsequently, a thermal disinfection system for femoral heads from living donors (Lobator Marburg Bone Bank System, Telos GmbH, Hungen, Germany) was developed. A

  1. MR evaluation of the articular cartilage of the femoral head during traction. Correlation with resected femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, K. [Osaka Seamens Insurance Hospital (Japan). Dept. of Radiology; Tanaka, H.; Narumi, Y.; Nakamura, H. [Osaka Univ. Medical School (Japan). Dept. of Radiology; Nishii, T.; Masuhara, K. [Osaka Univ. Medical School (Japan). Dept. of Orthopedic Surgery

    1999-01-01

    Objective: The purpose was to evaluate the articular cartilage of the hip joint with MR during traction and compare the findings with the resected specimen or arthroscopic findings. Material and Methods: Eight healthy volunteers, 5 patients with osteonecrosis, 5 with acetabular dysplasia, and 5 with advanced osteoarthrosis underwent MR imaging to evaluate the articular cartilage of the hip joint. Coronal fat-suppressed 3D spoiled gradient-echo (SPGR) images were obtained during traction. Identical imaging was performed of all the resected femoral heads of the osteonecrosis and advanced osteoarthrosis patients, and was correlated with the macroscopic pathological findings. Results: The traction was effective and the femoral articular cartilage was clearly identified in all 8 control subjects, and in all cases of osteonecrosis and acetabular dysplasia. In 4 cases of osteonecrosis, chondral fracture was identified in the boundary between the necrosis and the normal area. In all cases of advanced osteoarthrosis, cartilage was identified only at the medial side. The MR images of osteonecrosis and advanced osteoarthrosis corresponded well with the MR images of the resected femoral heads and the macroscopic findings. (orig.)

  2. Femoral neck fracture following groin irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Grigsby, Perry W; Roberts, Heidi L; Perez, Carlos A

    1995-04-30

    Purpose: The incidence and risk factors are evaluated for femoral neck fracture following groin irradiation for gynecologic malignancies. Methods and Materials: The radiation therapy records of 1313 patients with advanced and recurrent cancer of the vagina, vulva, cervix, and endometrium, treated at the Mallinckrodt Institute of Radiology from 1954 to 1992, were reviewed. Median follow-up was 12.7 years. From this group, 207 patients were identified who received irradiation to the pelvis and groins with anterposterior-posterior anterior (AP-PA), 18 MV photons. Data were reviewed regarding irradiation dose to the femoral neck and other presumed risk factors including age, primary site, stage, groin node status, menopausal status, estrogen use, cigarette use, alcohol consumption, and osteoporosis. Results: The per-patient incidence of femoral neck fracture was 4.8% (10 out of 207). Four patients developed bilateral fractures. However, the cumulative actuarial incidence of fracture was 11% at 5 years and 15% at 10 years. Cox multivariate analysis of age, weight, and irradiation dose showed that only irradiation dose may be important to developing fracture. Step-wise logistic regression of presumed prognostic factors revealed that only cigarette use and x-ray evidence of osteoporosis prior to irradiation treatment were predictive of fracture. Conclusion: Femoral head fracture is a common complication of groin irradiation for gynecologic malignancies. Fracture in our database appears to be related to irradiation dose, cigarette use, and x-ray evidence of osteoporosis. Special attention should be given in treatment planning (i.e., shielding of femoral head/neck and use of appropriate electron beam energies for a portion of treatment) to reduce the incidence of this complication.

  3. Femoral neck fracture following groin irradiation

    International Nuclear Information System (INIS)

    Grigsby, Perry W.; Roberts, Heidi L.; Perez, Carlos A.

    1995-01-01

    Purpose: The incidence and risk factors are evaluated for femoral neck fracture following groin irradiation for gynecologic malignancies. Methods and Materials: The radiation therapy records of 1313 patients with advanced and recurrent cancer of the vagina, vulva, cervix, and endometrium, treated at the Mallinckrodt Institute of Radiology from 1954 to 1992, were reviewed. Median follow-up was 12.7 years. From this group, 207 patients were identified who received irradiation to the pelvis and groins with anterposterior-posterior anterior (AP-PA), 18 MV photons. Data were reviewed regarding irradiation dose to the femoral neck and other presumed risk factors including age, primary site, stage, groin node status, menopausal status, estrogen use, cigarette use, alcohol consumption, and osteoporosis. Results: The per-patient incidence of femoral neck fracture was 4.8% (10 out of 207). Four patients developed bilateral fractures. However, the cumulative actuarial incidence of fracture was 11% at 5 years and 15% at 10 years. Cox multivariate analysis of age, weight, and irradiation dose showed that only irradiation dose may be important to developing fracture. Step-wise logistic regression of presumed prognostic factors revealed that only cigarette use and x-ray evidence of osteoporosis prior to irradiation treatment were predictive of fracture. Conclusion: Femoral head fracture is a common complication of groin irradiation for gynecologic malignancies. Fracture in our database appears to be related to irradiation dose, cigarette use, and x-ray evidence of osteoporosis. Special attention should be given in treatment planning (i.e., shielding of femoral head/neck and use of appropriate electron beam energies for a portion of treatment) to reduce the incidence of this complication

  4. Treatment of the femoral neck peudoarthrosis in childhood: Case report

    Directory of Open Access Journals (Sweden)

    Vukašinović Zoran

    2013-01-01

    Full Text Available Introduction. Femoral neck fractures in children and adolescents are rare. However, their complications are frequent - avascular necrosis, femoral neck pseudoarthrosis, premature physeal closure with consequent growth disturbance and coxa vara deformity. Case Outline. A 9.5­year­old boy was injured in a car accident, and femoral neck fracture was diagnosed. Prior to admission at our hospital he was surgically treated several times. He was admitted at our hospital eight months following the accident. On the X­ray transcervical pseudoarthrosis of the femoral neck was found, as well as coxa vara deformity and metaphyseal avascular necrosis. He was operated at our hospital; all previously placed ostefixation material was removed, valgus osteotomy of 30 degrees was done as well as additional local osteoplasty using the commercial osteoindactive agent (Osteovit®. Postoperatively, we applied skin traction, bed rest and physical therapy. At the final follow­up, the patient was recovered completely. He is now painless, the legs are of equal length, range of movements in the left hip is full, life activity is normal. The X­ray shows that the femoral neck pseudoarthrosis is fully healed. Conclusion. This case is presented in order to encourage other colleagues to challenge the problematic situation such as this one. Also, we would like to remind them what one should think about and what should be taken into consideration in the primary treatment of femoral neck fractures in children. Valgus femoral osteotomy, as a part of the primary treatment of femoral neck fracture in children (identically as in the adults can prevent the occurrence of femoral neck pseudoarthrosis.

  5. 99mTc-MDP scintigraphy of femoral head necrosis following femoral neck fracture

    International Nuclear Information System (INIS)

    Lee, Soon Jin; Lee, Jun Hyung; Kim, Eun Kyung; Lee, Sun Wha; Kim, Soon Yong

    1985-01-01

    Secondary ischemic necrosis of femoral head due to loss of blood supply following to femoral neck fracture is well known. The regional distribution of bone-seeking radiopharmaceuricals in the skeleton can depend on a number of factors, but bone blood flow is a major physiological determinant of regional skeletal uptake of Tc-99m polyphosphate and bone imaging may thus be used for the evaluation of vascularity of the femoral head. The authors made a comparative study of scintigraphic findings and operative findings of 28 cases of femoral neck fracture treated at Kyung Hee University Hospital from April 1980 to May 1984. The results were as follows: 1. In 16 cases of proven avascular necorsis of femoral head, scintigraphy showed absent or decreased activity in 14 cases (87.5%), while radiography showed increased density in 10 cases (62.5%). 2. In 12 cases of proven vital femoral head, scintigraphy showed increased activity in 9 cases (75%) and radiography showed decreased density in 9 cases (75%). 3. 99mTc-MDP scintigraphy was an excellent and useful method for assessing bone vitality of femoral head

  6. Can interposition of a silicone implant after sapheno-femoral ligation prevent recurrent varicose veins?

    NARCIS (Netherlands)

    de Maeseneer, M. G.; Giuliani, D. R.; van Schil, P. E.; de Hert, S. G.

    2002-01-01

    OBJECTIVES: To investigate whether a silicone implant at the sapheno-femoral ligation site could prevent recurrent varicosities. MATERIALS AND METHODS: Two non-randomised groups of patients were studied prospectively. In group A 173 patients and 212 limbs had sapheno-femoral ligation, while 172

  7. In Vitro Testing of Femoral Impaction Grafting With Porous Titanium Particles: A Pilot Study.

    NARCIS (Netherlands)

    Aquarius, Rene; Walschot, Luc; Buma, Pieter; Schreurs, Berend Willem; Verdonschot, Nicolaas Jacobus Joseph

    2009-01-01

    The disadvantages of allografts to restore femoral bone defects during revision hip surgery have led to the search for alternative materials. We investigated the feasibility of using porous titanium particles and posed the following questions: (1) Is it possible to create a high-quality femoral

  8. PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study.

    Science.gov (United States)

    Cowie, Raelene M; Briscoe, Adam; Fisher, John; Jennings, Louise M

    2016-11-01

    PEEK-OPTIMA ™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA ™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA ™ femoral components articulating against all-polyethylene tibial components was carried out under two kinematic conditions: 3 million cycles under intermediate kinematics (maximum anterior-posterior displacement of 5 mm) followed by 3 million cycles under high kinematic conditions (anterior-posterior displacement 10 mm). The wear of the GUR1020 ultra-high-molecular-weight polyethylene tibial components was assessed by gravimetric analysis; for both material combinations under each kinematic condition, the mean wear rates were low, that is, below 5 mm 3 /million cycles. Specifically, under intermediate kinematic conditions, the wear rate of the ultra-high-molecular-weight polyethylene tibial components was 0.96 ± 2.26 mm 3 /million cycles and 2.44 ± 0.78 mm 3 /million cycle against cobalt chrome and PEEK-OPTIMA ™ implants, respectively (p = 0.06); under high kinematic conditions, the wear rates were 2.23 ± 1.85 mm 3 /million cycles and 4.44 ± 2.35 mm 3 /million cycles, respectively (p = 0.03). Following wear simulation, scratches were apparent on the surface of the PEEK-OPTIMA ™ femoral components. The surface topography of the femoral components was assessed using contacting profilometry and showed a statistically significant increase in measured surface roughness of the PEEK-OPTIMA ™ femoral components compared to the cobalt chrome implants. However, this did not appear to influence the wear rate, which remained linear over the duration of

  9. PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study

    Science.gov (United States)

    Cowie, Raelene M; Briscoe, Adam; Fisher, John; Jennings, Louise M

    2016-01-01

    PEEK-OPTIMA™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA™ femoral components articulating against all-polyethylene tibial components was carried out under two kinematic conditions: 3 million cycles under intermediate kinematics (maximum anterior-posterior displacement of 5 mm) followed by 3 million cycles under high kinematic conditions (anterior-posterior displacement 10 mm). The wear of the GUR1020 ultra-high-molecular-weight polyethylene tibial components was assessed by gravimetric analysis; for both material combinations under each kinematic condition, the mean wear rates were low, that is, below 5 mm3/million cycles. Specifically, under intermediate kinematic conditions, the wear rate of the ultra-high-molecular-weight polyethylene tibial components was 0.96 ± 2.26 mm3/million cycles and 2.44 ± 0.78 mm3/million cycle against cobalt chrome and PEEK-OPTIMA™ implants, respectively (p = 0.06); under high kinematic conditions, the wear rates were 2.23 ± 1.85 mm3/million cycles and 4.44 ± 2.35 mm3/million cycles, respectively (p = 0.03). Following wear simulation, scratches were apparent on the surface of the PEEK-OPTIMA™ femoral components. The surface topography of the femoral components was assessed using contacting profilometry and showed a statistically significant increase in measured surface roughness of the PEEK-OPTIMA™ femoral components compared to the cobalt chrome implants. However, this did not appear to influence the wear rate, which remained linear over the duration of the study. These

  10. Evaluation of perfusion of the femoral head after femoral neck fracture using bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Satoshi; Ishido, Yasuhiro [Saiseikai Sendai Hospital, Kagoshima (Japan); Okano, Toshihiro [Ibusuki National Hospital, Kagoshima (Japan); Komiya, Setsuro [Kagoshima Univ. (Japan). Faculty of Medicine

    2002-09-01

    We treated 13 patients for femoral neck fracture. They consisted of 2 males and 11 females, and were classified according to Garden stage classification; Stage I, 3 cases; Stage II, 2 cases; Stage III, 2 cases; Stage IV, 4 cases. Two trochanteric fracture cases were used by control. We evaluated perfusion of the femoral head after femoral neck fracture using bone scintigraphy, which is considered useful for evaluation of perfusion of the femoral neck before operation. (author)

  11. Evaluation of perfusion of the femoral head after femoral neck fracture using bone scintigraphy

    International Nuclear Information System (INIS)

    Yamaguchi, Satoshi; Ishido, Yasuhiro; Okano, Toshihiro; Komiya, Setsuro

    2002-01-01

    We treated 13 patients for femoral neck fracture. They consisted of 2 males and 11 females, and were classified according to Garden stage classification; Stage I, 3 cases; Stage II, 2 cases; Stage III, 2 cases; Stage IV, 4 cases. Two trochanteric fracture cases were used by control. We evaluated perfusion of the femoral head after femoral neck fracture using bone scintigraphy, which is considered useful for evaluation of perfusion of the femoral neck before operation. (author)

  12. Radiological assessment of the femoral bowing in Japanese population

    Directory of Open Access Journals (Sweden)

    Abdelaal Ahmed Hamed Kassem

    2016-01-01

    Full Text Available Introduction: Differences in the magnitude of bowing between races are well-known characteristics of the femur. Asian races have an increased magnitude of femoral bowing but most of the orthopedic implants designed for the femur do not match this exaggerated bowing. We calculated the sagittal and coronal femoral bowing in the Japanese population at different levels of the femur and addressed its surgical significance. Material and methods: We calculated the sagittal and coronal bowing of 132 Japanese femora using CT scan of the femur. A mathematical calculation of the radius of curvature at proximal, middle, and distal regions of the femur was used to determine the degree of femoral bowing. Results: Mean sagittal bowing of the femur was 581, 188, and 161 mm for the proximal, middle, and distal thirds of the femur and mean lateral bowing was 528, 5092, and 876 mm, respectively. Mean sagittal and coronal bowing for the whole femur was 175 and 2640 mm, respectively. No correlation was found between age, gender, length of femur, and the degree of bowing. Conclusion: Our study reveals that femoral bowing in the Japanese population is 175 mm in the sagittal plane and 2640 mm in the coronal plane; these values are greater than the femoral bowing in other ethnic groups studied in the literature. This may result in varying degrees of mismatch between the western-manufactured femoral intramedullary implants and the Japanese femur. We recommend that orthopedic surgeons to accurately perform preoperative evaluation of the femoral bowing to avoid potential malalignment, rotation, and abnormal stresses between the femur and implant.

  13. Comparison of femoral morphology and bone mineral density between femoral neck fractures and trochanteric fractures.

    Science.gov (United States)

    Maeda, Yuki; Sugano, Nobuhiko; Saito, Masanobu; Yonenobu, Kazuo

    2011-03-01

    Many studies that analyzed bone mineral density (BMD) and skeletal factors of hip fractures were based on uncalibrated radiographs or dual-energy xray absorptiometry (DXA). Spatial accuracy in measuring BMD and morphologic features of the femur with DXA is limited. This study investigated differences in BMD and morphologic features of the femur between two types of hip fractures using quantitative computed tomography (QCT). Forty patients with hip fractures with normal contralateral hips were selected for this study between 2003 and 2007 (trochanteric fracture, n=18; femoral neck fracture, n=22). Each patient underwent QCT of the bilateral femora using a calibration phantom. Using images of the intact contralateral femur, BMD measurements were made at the point of minimum femoral-neck cross-sectional area, middle of the intertrochanteric region, and center of the femoral head. QCT images also were used to measure morphologic features of the hip, including hip axis length, femoral neck axis length, neck-shaft angle, neck width, head offset, anteversion of the femoral neck, and cortical index at the femoral isthmus. No significant differences were found in trabecular BMD between groups in those three regions. Patients with trochanteric fractures showed a smaller neck shaft angle and smaller cortical index at the femoral canal isthmus compared with patients with femoral neck fractures. We conclude that severe osteoporosis with thinner cortical bone of the femoral diaphysis is seen more often in patients with trochanteric fracture than in patients with femoral neck fracture. Level IV, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.

  14. {sup 99m}Tc-MDP scintigraphy of femoral head necrosis following femoral neck fracture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soon Jin; Lee, Jun Hyung; Kim, Eun Kyung; Lee, Sun Wha; Kim, Soon Yong [Kyung Hee University School of Medicine, Seoul (Korea, Republic of)

    1985-02-15

    Secondary ischemic necrosis of femoral head due to loss of blood supply following to femoral neck fracture is well known. The regional distribution of bone-seeking radiopharmaceuricals in the skeleton can depend on a number of factors, but bone blood flow is a major physiological determinant of regional skeletal uptake of Tc-99m polyphosphate and bone imaging may thus be used for the evaluation of vascularity of the femoral head. The authors made a comparative study of scintigraphic findings and operative findings of 28 cases of femoral neck fracture treated at Kyung Hee University Hospital from April 1980 to May 1984. The results were as follows: 1. In 16 cases of proven avascular necorsis of femoral head, scintigraphy showed absent or decreased activity in 14 cases (87.5%), while radiography showed increased density in 10 cases (62.5%). 2. In 12 cases of proven vital femoral head, scintigraphy showed increased activity in 9 cases (75%) and radiography showed decreased density in 9 cases (75%). 3. 99mTc-MDP scintigraphy was an excellent and useful method for assessing bone vitality of femoral head.

  15. Transvenous liver biopsy via the femoral vein

    International Nuclear Information System (INIS)

    Khosa, F.; McNulty, J.G.; Hickey, N.; O'Brien, P.; Tobin, A.; Noonan, N.; Ryan, B.; Keeling, P.W.N.; Kelleher, D.P.; McDonald, G.S.A.

    2003-01-01

    AIM: To study the safety, effectiveness and diagnostic value of transvenous forceps biopsy of the liver in 54 patients with coagulopathy, gross ascites or morbid obesity and suspected liver disease in whom percutaneous liver biopsy was contraindicated. MATERIAL AND METHODS: Forceps biopsy of the liver via the femoral vein was attempted in 54 adult patients with advanced liver disease of unknown aetiology who had coagulation disorders (41 cases), gross ascites (11 cases) or morbid obesity (two cases). In each patient two to six biopsies (average four) were taken using a radial jaw forceps inserted via the right or left femoral vein. RESULTS: The procedure was successful in 53 cases. Hepatic vein catheterization failed in one patient. Adequate liver tissue for diagnosis was obtained in 84% of cases. One patient developed delayed haemorrhage at 12 h from a capsular leak that was undetected during the biopsy procedure. This patient required blood transfusions and laparotomy to control bleeding. There were no deaths in the 53 patients studied. Transient minor chest and shoulder pain was encountered during sheath insertion into a hepatic vein in 23 patients. Three patients developed a femoral vein haematoma, which resolved with conservative treatment. CONCLUSION: Transvenous liver biopsy via the femoral vein is another safe, effective, simple alternative technique of biopsy when the percutaneous route is contraindicated

  16. Dynamic gadolinium-enhanced MRI evaluation of porcine femoral head ischemia and reperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T. [Clinic for Orthopaedics and Sports Traumatology, Dreifaltigkeits-Krankenhaus GmbH, Aachener Str. 445-449, 50933 Koeln (Germany); Drescher, W. [Department of Orthopaedics, Christian Albrechts University, Kiel (Germany); Becker, C. [Department of Orthopaedics, Heinrich Heine University, Duesseldorf (Germany); Sangill, R.; Stoedkilde-Joergensen, H. [Institute for Magnetic Resonance Imaging Tomography, University of Aarhus, Skejby Hospital, Aarhus (Denmark); Heydthausen, M. [Computing Center, Heinrich Heine University, Duesseldorf (Germany); Hansen, E.S.; Buenger, C. [Spine Section, Department of Orthopaedics, University of Aarhus (Denmark)

    2003-02-01

    To examine the potential of gadolinium (Gd)-enhanced dynamic MRI in the detection of early femoral head ischemia. Furthermore, to apply a three-compartment model to achieve a clinically applicable MR index for femoral head perfusion during the steady state and arterial hip joint tamponade.Design and materials In a porcine model femoral head perfusion was measured by radioactive tracer microspheres and by using a dynamic Gd-enhanced MRI protocol. Femoral head perfusion measurements and MRI tests were performed unilaterally before, during and after the experimentally induced ischemia of one of the hip joints. Ischemia was induced by increasing intra-articular pressure to 250 mmHg. All pigs showed ischemia of the femoral head epiphysis under hip joint tamponade followed by reperfusion to the same level as before joint tamponade. In two cases perfusion after removal of tamponade continued to be low. In dynamic MRI measurements increases in signal intensity were seen after intravenous infusion of Gd-DTPA, followed by a slow decrease in signal intensity. The signal-intensity curve during femoral head ischemia had a minor increase. Also the coefficient determined was a helpful indicator of femoral head ischemia. Femoral head blood flow as measured by microspheres fell significantly under joint tamponade. Early detection of this disturbed regional blood flow was possible using a dynamic MRI procedure. A biomathematical model resulted from the evaluation of the intervals of signal intensity over time which allows detection of bone blood flow changes at a very early stage. Using this new method earlier detection of femoral head necrosis may be possible. (orig.)

  17. Correlation of ultrasound appearance, gross anatomy, and histology of the femoral nerve at the femoral triangle.

    Science.gov (United States)

    Lonchena, Tiffany K; McFadden, Kathryn; Orebaugh, Steven L

    2016-01-01

    Correlation between ultrasound appearance, gross anatomic characteristics, and histologic structure of the femoral nerve (FN) is lacking. Utilizing cadavers, we sought to characterize the anatomy of the FN, and provide a quantitative measure of its branching. We hypothesize that at the femoral crease, the FN exists as a group of nerve branches, rather than a single nerve structure, and secondarily, that this transition into many branches is apparent on ultrasonography. Nineteen preserved cadavers were investigated. Ultrasonography was sufficient to evaluate the femoral nerve in nine specimens; gross dissection was utilized in all 19. Anatomic characteristics were recorded, including distances from the inguinal ligament to femoral crease, first nerve branch, and complete arborization of the nerve. The nerves from nine specimens were excised for histologic analysis. On ultrasound, the nerve became more flattened, widened, and less discrete as it coursed distally. Branching of the nerve was apparent in 12 of 18 images, with mean distance from inguinal ligament of 3.9 (1.0) cm. However, upon dissection, major branching of the femoral nerve occurred at 3.1 (1.0) cm distal to the inguinal ligament, well proximal to the femoral crease. Histologic analysis was consistent with findings at dissection. The femoral nerve arborizes into multiple branches between the inguinal ligament and the femoral crease. Initial branching is often high in the femoral triangle. As hypothesized, the FN exists as a closely associated group of nerve branches at the level of the femoral crease; however, the termination of the nerve into multiple branches is not consistently apparent on ultrasonography.

  18. Femoral strength and posture in terrestrial birds and non-avian theropods.

    Science.gov (United States)

    Farke, Andrew A; Alicea, Justy

    2009-09-01

    Osteological and experimental evidence suggest a change in femoral posture between non-avian dinosaurs (in which the femur presumably was carried in a subvertical position) and birds (in which the femur is held nearly horizontal during most phases of terrestrial locomotion). In this study, we used a broad comparative sample to test the hypothesis that cross-sectional properties of the femur records evidence of this presumed change in posture. I(max) and I(min) (second moment of area, related to resistance to bending) and cross-sectional area (indicating resistance to compression) were measured from computed tomography scans of the femora of 30 species of flightless or primarily terrestrial birds, one probable non-dinosaur dinosauromorph, and at least four species of non-avian theropods. It was predicted that birds should have more eccentrically shaped femoral midshafts as measured by I(max)/II(min) (reflecting greater bending) and comparatively smaller cross-sectional areas than non-avians. Results show that no significant differences occur between non-avian dinosaurs and birds for any parameter, and the samples overlapped broadly in many cases. Thus, cross-sectional properties cannot be used to infer differences in femoral posture between the two groups. This surprising finding might be explained by the fact that femoral postures were not drastically different or that a gradation of postures occurred in each sample. It is also possible that bone loading during life was not closely correlated with cross-sectional morphology. We conclude that cross-sectional properties should be used with caution in determining the posture and behaviors of extinct animals, and only in conjunction with other morphological information. (c) 2009 Wiley-Liss, Inc.

  19. Treatment of neglected femoral neck fracture

    Directory of Open Access Journals (Sweden)

    Anil K Jain

    2015-01-01

    Full Text Available Intra-capsular femoral neck fractures are seen commonly in elderly people following a low energy trauma. Femoral neck fracture has a devastating effect on the blood supply of the femoral head, which is directly proportional to the severity of trauma and displacement of the fracture. Various authors have described a wide array of options for treatment of neglected/nonunion (NU femoral neck fracture. There is lack of consensus in general, regarding the best option. This Instructional course article is an analysis of available treatment options used for neglected femoral neck fracture in the literature and attempt to suggest treatment guides for neglected femoral neck fracture. We conducted the "Pubmed" search with the keywords "NU femoral neck fracture and/or neglected femoral neck fracture, muscle-pedicle bone graft in femoral neck fracture, fibular graft in femoral neck fracture and valgus osteotomy in femoral neck fracture." A total of 203 print articles were obtained as the search result. Thirty three articles were included in the analysis and were categorized into four subgroups based on treatment options. (a treated by muscle-pedicle bone grafting (MPBG, (b closed/open reduction internal fixation and fibular grafting (c open reduction and internal fixation with valgus osteotomy, (d miscellaneous procedures. The data was pooled from all groups for mean neglect, the type of study (prospective or retrospective, classification used, procedure performed, mean followup available, outcome, complications, and reoperation if any. The outcome of neglected femoral neck fracture depends on the duration of neglect, as the changes occurring in the fracture area and fracture fragments decides the need and type of biological stimulus required for fracture union. In stage I and stage II (Sandhu′s staging neglected femoral neck fracture osteosynthesis with open reduction and bone grafting with MPBG or Valgus Osteotomy achieves fracture union in almost 90

  20. Subtrochanteric femoral fracture during trochanteric nailing for the treatment of femoral shaft fracture.

    Science.gov (United States)

    Yun, Ho Hyun; Oh, Chi Hun; Yi, Ju Won

    2013-09-01

    We report on three cases of subtrochanteric femoral fractures during trochanteric intramedullary nailing for the treatment of femoral shaft fractures. Trochanteric intramedullary nails, which have a proximal lateral bend, are specifically designed for trochanteric insertion. When combined with the modified insertion technique, trochanteric intramedullary nails reduce iatrogenic fracture comminution and varus malalignment. We herein describe technical aspects of trochanteric intramedullary nailing for femoral shaft fractures to improve its application and prevent implant-derived complications.

  1. Self-designed femoral neck guide pin locator for femoral neck fractures.

    Science.gov (United States)

    Xia, Shengli; Wang, Ziping; Wang, Minghui; Wu, Zuming; Wang, Xiuhui

    2014-01-01

    Closed reduction and fixation with 3 cannulated screws is a widely accepted surgery for the treatment of femoral neck fractures. However, how to obtain optimal screw placement remains unclear. In the current study, the authors designed a guide pin positioning system for femoral neck fracture cannulated screw fixation and examined its application value by comparing it with freehand guide needle positioning and with general guide pin locator positioning provided by equipment manufacturers. The screw reset rate, screw parallelism, triangle area formed by the link line of the entry point of 3 guide pins, and maximum vertical load bearing of the femoral neck after internal fixation were recorded. As expected, the triangle area was largest in the self-designed positioning group, followed by the general positioning group and the freehand positioning group. The difference among the 3 groups was statistically significant (P.05). The authors’ self-designed guide pin positioning system has the potential to accurately insert cannulated screws in femoral neck fractures and may reduce bone loss and unnecessary radiation.

  2. Macroscopic and microscopic findings in avascular necrosis of the femoral head.

    Science.gov (United States)

    Kamal, Diana; Alexandru, D O; Kamal, C K; Streba, C T; Grecu, D; Mogoantă, L

    2012-01-01

    The avascular necrosis of the femoral head is an illness induced by the cutoff of blood flow to the femoral head and it affects mostly young adults between the ages of 30 and 50 years, raising therapeutic and diagnostic issues. Many risk factors are incriminated in the development of avascular necrosis of the femoral head like: trauma, chronic alcohol consumption, smoking, administration of corticosteroid drugs, most of the cases are considered to be idiopathic. The main goal of our paper is to describe the macroscopic and microscopic variations of the bone structure, which occur in patients with avascular necrosis of the femoral head. The biological material needed for our study was obtained following hip arthroplasty surgery in 26 patients between the ages of 29 and 59 years, which previously were diagnosed with avascular necrosis of the femoral head and admitted in the Orthopedics Department of the Emergency County Hospital of Craiova (Romania) between 2010 and 2011. From a macroscopic point of view, we found well defined areas of necrosis, most of which were neatly demarcated of the adjacent viable tissue by hyperemic areas, loss of shape and contour of the femoral head and transformations of the articular cartilage above the area of necrosis. When examined under the microscope, we found vast areas of fibrosis, narrow bone trabeculae, obstructed blood vessels or blood vessels with clots inside, hypertrophic fat cells, bone sequestration but also small cells and pyknotic nuclei. The microscopic and macroscopic findings on the femoral head sections varied with the patients and the stage of the disease.

  3. Modeling Non-Linear Material Properties in Composite Materials

    Science.gov (United States)

    2016-06-28

    Technical Report ARWSB-TR-16013 MODELING NON-LINEAR MATERIAL PROPERTIES IN COMPOSITE MATERIALS Michael F. Macri Andrew G...REPORT TYPE Technical 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE MODELING NON-LINEAR MATERIAL PROPERTIES IN COMPOSITE MATERIALS ...systems are increasingly incorporating composite materials into their design. Many of these systems subject the composites to environmental conditions

  4. Comparison of Radial Access, Guided Femoral Access, and Non-Guided Femoral Access Among Women Undergoing Percutaneous Coronary Intervention.

    Science.gov (United States)

    Koshy, Linda M; Aberle, Laura H; Krucoff, Mitchell W; Hess, Connie N; Mazzaferri, Ernest; Jolly, Sanjit S; Jacobs, Alice; Gibson, C Michael; Mehran, Roxana; Gilchrist, Ian C; Rao, Sunil V

    2018-01-01

    This study was conducted to determine the association between radial access, guided femoral access, and non-guided femoral access on postprocedural bleeding and vascular complications after percutaneous coronary intervention (PCI). Bleeding events and major vascular complications after PCI are associated with increased morbidity, mortality, and cost. While the radial approach has been shown to be superior to the femoral approach in reducing bleeding and vascular complications, whether the use of micropuncture, fluoroscopy, or ultrasound mitigates these differences is unknown. We conducted a post hoc analysis of women in the SAFE-PCI for Women trial who underwent PCI and had the access method identified (n = 643). The primary endpoint of postprocedure bleeding or vascular complications occurring within 72 hours or at discharge was adjudicated by an independent clinical events committee and was compared based on three categories of access technique: radial, guided femoral (fluoroscopy, micropuncture, ultrasound), or non-guided femoral (none of the aforementioned). Differences between the groups were determined using multivariate logistic regression using radial access as the reference. Of the PCI population, 330 underwent radial access, 228 underwent guided femoral access, and 85 underwent non-guided femoral access. There was a statistically significant lower incidence of the primary endpoint with radial access vs non-guided femoral access; however, there was no significant difference between radial approach and femoral access guided by fluoroscopy, micropuncture, or ultrasound. This post hoc analysis demonstrates that while radial access is safer than non-guided femoral access, guided femoral access appears to be associated with similar bleeding events or vascular complications as radial access.

  5. Evaluation of a pig femoral head osteonecrosis model

    Directory of Open Access Journals (Sweden)

    Kim Harry

    2010-03-01

    Full Text Available Abstract Background A major cause of osteonecrosis of the femoral head is interruption of a blood supply to the proximal femur. In order to evaluate blood circulation and pathogenetic alterations, a pig femoral head osteonecrosis model was examined to address whether ligature of the femoral neck (vasculature deprivation induces a reduction of blood circulation in the femoral head, and whether transphyseal vessels exist for communications between the epiphysis and the metaphysis. We also tested the hypothesis that the vessels surrounding the femoral neck and the ligamentum teres represent the primary source of blood flow to the femoral head. Methods Avascular osteonecrosis of the femoral head was induced in Yorkshire pigs by transecting the ligamentum teres and placing two ligatures around the femoral neck. After heparinized saline infusion and microfil perfusion via the abdominal aorta, blood circulation in the femoral head was evaluated by optical and CT imaging. Results An angiogram of the microfil casted sample allowed identification of the major blood vessels to the proximal femur including the iliac, common femoral, superficial femoral, deep femoral and circumflex arteries. Optical imaging in the femoral neck showed that a microfil stained vessel network was visible in control sections but less noticeable in necrotic sections. CT images showed a lack of microfil staining in the epiphysis. Furthermore, no transphyseal vessels were observed to link the epiphysis to the metaphysis. Conclusion Optical and CT imaging analyses revealed that in this present pig model the ligatures around the femoral neck were the primary cause of induction of avascular osteonecrosis. Since the vessels surrounding the femoral neck are comprised of the branches of the medial and the lateral femoral circumflex vessels, together with the extracapsular arterial ring and the lateral epiphyseal arteries, augmentation of blood circulation in those arteries will improve

  6. Morphometric findings in avascular necrosis of the femoral head.

    Science.gov (United States)

    Kamal, Diana; Trăistaru, Rodica; Alexandru, D O; Kamal, C K; Pirici, D; Pop, O T; Mălăescu, D Gh

    2012-01-01

    Avascular necrosis of the femoral head is an illness with a controversial etiology, the trigger event being the suppression of blood flow to the femoral head. The disease affects mostly young adults within their third and fifth decade, the majority of the patients being men. The main risk factors are trauma, chronic alcohol consumption, smoking, corticotherapy. The main goal of our study is to describe the morphometric changes found in the bone tissue of patients diagnosed with avascular necrosis of the femoral head, with different risk factors, by comparing the area of bone trabeculae inside the area of necrosis with that from the adjacent viable tissue. The morphometric study used biological material from 16 patients with ages between 29 and 57 years, who underwent surgery for avascular necrosis of the femoral head. They were admitted in the Orthopedics Department at the Emergency County Hospital in Craiova between 2010 and 2011 and were split into four groups. Group I presented trauma as the main risk factor, Group II had corticotherapy as the defining risk factor, Group III presented chronic alcohol consumption and Group IV was represented by the patients who smoked and exhibited chronic alcohol consumption. There was not a significant statistical difference between the areas of bone trabeculae of the four groups when we compared viable bone tissue to the necrotized one. Knowing the risk factors of the avascular necrosis of the femoral head is critical to the management of the disease, because diagnosing it in an early stage is a necessity for obtaining a good result for conservative treatment.

  7. Outcomes of trochanteric femoral fractures treated with proximal femoral nail: an analysis of 100 consecutive cases

    Directory of Open Access Journals (Sweden)

    Korkmaz MF

    2014-04-01

    Full Text Available Mehmet Fatih Korkmaz,1 Mehmet Nuri Erdem,2 Zeliha Disli,3 Engin Burak Selcuk,4 Mustafa Karakaplan,1 Abdullah Gogus5 1Department of Orthopedics and Traumatology, Inonu University School of Medicine, Malatya, Turkey; 2Department of Orthopedics and Traumatology, Nisantasi University School of Medicine, Istanbul, Turkey; 3Department of Anesthesiology, Malatya Government Hospital, Malatya, Turkey; 4Department of Family Medicine, Inonu University School of Medicine, Malatya, Turkey; 5Department of Orthopedics and Traumatology, Florence Nightingale Hospital, Istanbul, Turkey Purpose: In this study, we aimed to report the results of a retrospective study carried out at our institute regarding cases of patients who had suffered proximal femoral fractures between January 2002 and February 2007, and who were treated with a proximal femoral nail. Materials and methods: One hundred consecutive cases were included in the study. A case documentation form was used to obtain intraoperative data including age, sex, mechanism of injury, type of fracture according to Association for Osteosynthesis/Association for the Study of Internal Fixation (AO/ASIF classification and the American Society of Anesthesiologists' (ASA physical status classification (ASA grade. Clinical and radiographic examinations were performed at the time of admission and at the 6th week; subsequent visits were organized on the 3rd month, 6th month, and 12th month, and in patients with longer follow-up and annually postoperatively. The Harris score of hip function was used, and any change in the position of the implants and the progress of the fracture union, which was determined radiologically, was noted. Results: The mean age of the patients was 77.66 years (range: 37–98 years, and the sex distribution was 32 males and 68 females. Seventy-three fractures were reduced by closed means, whereas 27 needed limited open reduction. The mean follow-up time for the study group was 31.3 months (range

  8. Lateral femoral traction pin entry: risk to the femoral artery and other medial neurovascular structures

    Directory of Open Access Journals (Sweden)

    Appleton Paul

    2010-01-01

    Full Text Available Abstract Background Femoral skeletal traction assists in the reduction and transient stabilization of pelvic, acetabular, hip, and femoral fractures when splinting is ineffective. Traditional teaching has recommended a medial entry site for insertion of the traction pin in order to minimize injury to the femoral artery as it passes through Hunter's canal. The present anatomical study evaluates the risk to the femoral artery and other medial neurovascular structures using a lateral entry approach. Methods Six embalmed cadavers (twelve femurs were obtained for dissection. Steinman pins were drilled from lateral to medial at the level of the superior pole of the patella, at 2 cm, and at 4 cm proximal to this point. Medial superficial dissection was then performed to identify the saphenous nerve, the superior medial geniculate artery, the adductor hiatus, the tendinous insertion of the adductor magnus and the femoral artery. Measurements localizing these anatomic structures relative to the pins were obtained. Results The femoral artery was relatively safe and was no closer than 29.6 mm (mean from any of the three Steinman pins. The superior medial geniculate artery was the medial structure at most risk. Conclusions Lateral femoral traction pin entry is a safe procedure with minimal risk to the saphenous nerve and femoral artery. Of the structures examined, only the superior medial geniculate artery is at a risk of iatrogenic injury due to its position. The incidence of such injury in clinical practice and its clinical significance is not known. Lateral insertion facilitates traction pin placement since it minimizes the need to move the contralateral extremity out of the way of the drilling equipment or the need to elevate or externally rotate the injured extremity relative to the contralateral extremity.

  9. Microstructure analysis and wear behavior of titanium cermet femoral head with hard TiC layer.

    Science.gov (United States)

    Luo, Yong; Ge, Shirong; Liu, Hongtao; Jin, Zhongmin

    2009-12-11

    Titanium cermet was successfully synthesized and formed a thin gradient titanium carbide coating on the surface of Ti6Al4V alloy by using a novel sequential carburization under high temperature, while the titanium cermet femoral head was produced. The titanium cermet phase and surface topography were characterized with X-ray diffraction (XRD) and backscattered electron imaging (BSE). And then the wear behavior of titanium cermet femoral head was investigated by using CUMT II artificial joint hip simulator. The surface characterization indicates that carbon effectively diffused into the titanium alloys and formed a hard TiC layer on the Ti6Al4V alloys surface with a micro-porous structure. The artificial hip joint experimental results show that titanium cermet femoral head could not only improve the wear resistance of artificial femoral head, but also decrease the wear of UHMWPE joint cup. In addition, the carburized titanium alloy femoral head could effectively control the UHMWPE debris distribution, and increase the size of UHMWPE debris. All of the results suggest that titanium cermet is a prospective femoral head material in artificial joint.

  10. Varus femoral osteotomy improves sphericity of the femoral head in older children with severe form of Legg-Calvé-Perthes disease.

    Science.gov (United States)

    Terjesen, Terje; Wiig, Ola; Svenningsen, Svein

    2012-09-01

    In the Norwegian prospective study on Legg-Calvé-Perthes disease (LCPD), we found varus femoral osteotomy gave better femoral head sphericity at a mean of 5 years postoperative than physiotherapy in children older than 6.0 years at diagnosis with femoral head necrosis of more than 50%. That study did not include separate analyses for hips with 100% necrosis and those with a percentage of necrosis between 50% and 100%. We asked whether (1) femoral osteotomy improves femoral head sphericity at followup in all patients with more than 50% femoral head necrosis or in selected groups only and (2) there is a critical age between 6.0 and 10.0 years over which femoral osteotomy does not improve the prognosis. We treated 70 patients with unilateral LCPD, age at diagnosis of more than 6.0 years, and femoral head necrosis of more than 50% with varus femoral osteotomy between 1996 and 2000. We classified necrosis using the Catterall classification. We established a control group of 51 similar children who received physiotherapy. At the 5-year followup visit, the hips were graded according to femoral head shape: spherical, ovoid, or flat. At 5-year followup, there was no difference between the treatment groups in radiographic outcome in Catterall Group 3 hips. In Catterall Group 4 hips, femoral head sphericity was better in the osteotomy group, with flat femoral heads in 14% compared to 75% after physiotherapy. The same trend toward better head sphericity occurred when the lateral pillar classification was used. In children aged 6.0 to 10.0 years, in whom the whole femoral head is affected, femoral head sphericity 5 years after femoral osteotomy was better than that after physiotherapy.

  11. Preoperative virtual reduction reduces femoral malrotation in the treatment of bilateral femoral shaft fractures.

    Science.gov (United States)

    Omar, Mohamed; Suero, Eduardo M; Hawi, Nael; Decker, Sebastian; Krettek, Christian; Citak, Musa

    2015-10-01

    In bilateral femoral shaft fractures, significant malrotation (>15°) occurs in about 40 % of cases after intramedullary nailing. Most of the methods that provide rotational control during surgery are based on a comparison to the intact femur and, thus, not applicable for bilateral fractures. In this study, we evaluated if preoperative virtual reduction can help improving rotational alignment in patients with bilateral femoral shaft fractures. Seven patients with bilateral femoral shaft fractures were initially treated with external fixation of both femurs. After obtaining a CT scan of both legs, the fractures were reduced virtually using the software program VoXim®, and the amount and direction of rotational correction were calculated. Subsequently, the patients were treated by antegrade femoral nailing and rotation was corrected to the preoperatively calculated amount. After external fixation, the mean rotational difference between both legs was 15.0° ± 10.2°. Four out of seven patients had a significant malrotation over 15°. Following virtual reduction, the mean rotational difference between both legs was 2.1° ± 1.2°. After intramedullary nailing, no case of malrotation occurred and the mean rotational difference was 6.1° ± 2.8°. Preoperative virtual reduction allows determining the pretraumatic femoral antetorsion and provided useful information for the definitive treatment of bilateral femoral shaft fractures. We believe that this procedure is worth being implemented in the clinical workflow to avoid malrotation after intramedullary nailing.

  12. [Trochanteric femoral fractures].

    Science.gov (United States)

    Douša, P; Čech, O; Weissinger, M; Džupa, V

    2013-01-01

    At the present time proximal femoral fractures account for 30% of all fractures referred to hospitals for treatment. Our population is ageing, the proportion of patients with post-menopausal or senile osteoporosis is increasing and therefore the number of proximal femoral fractures requiring urgent treatment is growing too. In the age category of 50 years and older, the incidence of these fractures has increased exponentially. Our department serves as a trauma centre for half of Prague and part of the Central Bohemia Region with a population of 1 150 000. Prague in particular has a high number of elderly citizens. Our experience is based on extensive clinical data obtained from the Register of Proximal Femoral Fractures established in 1997. During 14 years, 4280 patients, 3112 women and 1168 men, were admitted to our department for treatment of proximal femoral fractures. All patients were followed up until healing or development of complications. In the group under study, 82% were patients older than 70 years; 72% of those requiring surgery were in their seventies and eighties. Men were significantly younger than women (pfractures were 2.3-times more frequent in women than in men. In the category under 60 years, men significantly outnumbered women (pfractures were, on the average, eight years older than the patients with intertrochanteric fractures, which is a significant difference (pTrochanteric fractures accounted for 54.7% and femoral neck fractures for 45.3% of all fractures. The inter-annual increase was 5.9%, with more trochanteric than femoral neck fractures. There was a non-significant decrease in intertrochanteric (AO 31-A3) fractures. On the other hand, the number of pertrochanteric (AO 31-A1+2) fractures increased significantly (pfractures were treated with a proximal femoral nail; a short nail was used in 1260 and a long nail in 134 of them. A dynamic hip screw (DHS) was employed to treat 947 fractures. Distinguishing between pertrochanteric (21-A1

  13. To study the role of dynamic magnetic resonance imaging in assessing the femoral head vascularity in intracapsular femoral neck fractures

    Energy Technology Data Exchange (ETDEWEB)

    Kaushik, Abhishek, E-mail: abhiortho27@gmail.co [Department of Orthopedics, 513, Thermal Colony, Sector-22, Faridabad 121005, Haryana (India); Sankaran, Balu; Varghese, Mathew [Department of Orthopedics, St Stephen' s Hospital, Tis hazari, Delhi, New Delhi 110054 (India)

    2010-09-15

    Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in predicting vascularity after femoral neck fracture are 87%, 88% and 87%, respectively. Type A or Type B curve pattern is a positive factor to successful osteosynthesis with p value <0.0001 (Chi-square test). This is a statistically significant value. From this finding it can be suggested that the reliability of dynamic curves A and B in predicting maintained vascularity of femoral head is high. This investigation can be used to predict the vascularity of femoral head after intracapsular femoral neck fractures. There was a good correlation between the outcomes of fractures and dynamic MRI curves done within 48 h of injury. This signifies the role of dynamic MRI in predicting the vascularity of femoral head as early as 48 h. A treatment algorithm can be suggested on the basis of dynamic MRI curves. The fractures with Type C dynamic curve should be considered as fractures with poor vascularity of femoral head and measures to enhance the vascularity of femoral head along with rigid internal fixation should be undertaken to promote

  14. To study the role of dynamic magnetic resonance imaging in assessing the femoral head vascularity in intracapsular femoral neck fractures

    International Nuclear Information System (INIS)

    Kaushik, Abhishek; Sankaran, Balu; Varghese, Mathew

    2010-01-01

    Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in predicting vascularity after femoral neck fracture are 87%, 88% and 87%, respectively. Type A or Type B curve pattern is a positive factor to successful osteosynthesis with p value <0.0001 (Chi-square test). This is a statistically significant value. From this finding it can be suggested that the reliability of dynamic curves A and B in predicting maintained vascularity of femoral head is high. This investigation can be used to predict the vascularity of femoral head after intracapsular femoral neck fractures. There was a good correlation between the outcomes of fractures and dynamic MRI curves done within 48 h of injury. This signifies the role of dynamic MRI in predicting the vascularity of femoral head as early as 48 h. A treatment algorithm can be suggested on the basis of dynamic MRI curves. The fractures with Type C dynamic curve should be considered as fractures with poor vascularity of femoral head and measures to enhance the vascularity of femoral head along with rigid internal fixation should be undertaken to promote

  15. [Pathologic proximal femoral fractures in children in an unicameral bone cyst].

    Science.gov (United States)

    Havránek, P; Pesl, T; Bartonícek, J

    2005-01-01

    Proximal femoral fractures in children are rare, pathologic fractures being extremely rare. Despite many meanings these fractures are still "unsolved" there are some definite rules for treatment of true accidental injuries. Pathologic fractures are outstanding with their extremely rare incidence. The aim of the study is to overview a large clinical material, find out the incidence of this pathologic fracture, the extent and shape of the unicameral bone cyst (UBC), specific therapeutic approach, technical problems of eventual osteosynthesis, number of reoperations and sequels. Altogether 49 children with 50 accidental and pathologic fractures of proximal part of the femur treated in the Regional Pediatric Trauma Centre of the Department of Pediatric and Trauma Surgery, 3rd Faculty of Medicine, Charles University, Prague. Retrospective and prospective study of children (0 to 15 years of age) treated with proximal femoral accidental and pathologic fractures during the 20 year period (from August 1984 to November 2004). Classification of fractures according to Delbet and Colonna. Diagnosis of bone cyst with plain X-rays, eventually CT scans. During the 20 years period (August 1984 to November 2004) 49 children with 50 proximal femoral fractures were treated in the Department. Four patients sustained a pathologic fracture through an unicameral bone cyst. Two of these latter children were treated by an open reduction and osteosynthesis with the use of the proximal femoral AO-ASIF angled-plate and two children nonoperatively using skeletal traction because of impossibility of insertion of the osteosynthetic material without a damage of the growth plate. Subsequent operations of the UBC were necessary in these two children. All four patients recovered well without sequels. Pathologic fractures in UBC are usually treated nonoperatively and the cyst itself is treated after fracture healing. Proximal femoral impairment is the exception from this rule because of weigh bearing

  16. Femoral head avascular necrosis

    International Nuclear Information System (INIS)

    Chrysikopoulos, H.; Sartoris, D.J.; Resnick, D.L.; Ashburn, W.; Pretorius, T.

    1988-01-01

    MR imaging has been shown to be more sensitive and specific than planar scintigraphy for avascular necrosis (AVN) of the femoral head. However, experience with single photon emission CT (SPECT) is limited. The authors retrospectively compared 1.5-T MR imaging with SPECT in 14 patients with suspected femoral head AVN. Agreement between MR imaging and SPECT was present in 24 femurs, 14 normal and ten with AVN. MR imaging showed changes of AVN in the remaining four femoral heads. Of these, one was normal and the other three inconclusive for AVN by SPECT. The authors conclude that MR imaging is superior to SPECT for the evaluation of AVN of the hip

  17. Macroscopic anisotropic bone material properties in children with severe osteogenesis imperfecta.

    Science.gov (United States)

    Albert, Carolyne; Jameson, John; Tarima, Sergey; Smith, Peter; Harris, Gerald

    2017-11-07

    Children with severe osteogenesis imperfecta (OI) typically experience numerous fractures and progressive skeletal deformities over their lifetime. Recent studies proposed finite element models to assess fracture risk and guide clinicians in determining appropriate intervention in children with OI, but lack of appropriate material property inputs remains a challenge. This study aimed to characterize macroscopic anisotropic cortical bone material properties and investigate relationships with bone density measures in children with severe OI. Specimens were obtained from tibial or femoral shafts of nine children with severe OI and five controls. The specimens were cut into beams, characterized in bending, and imaged by synchrotron radiation X-ray micro-computed tomography. Longitudinal modulus of elasticity, yield strength, and bending strength were 32-65% lower in the OI group (p<0.001). Yield strain did not differ between groups (p≥0.197). In both groups, modulus and strength were lower in the transverse direction (p≤0.009), but anisotropy was less pronounced in the OI group. Intracortical vascular porosity was almost six times higher in the OI group (p<0.001), but no differences were observed in osteocyte lacunar porosity between the groups (p=0.086). Volumetric bone mineral density was lower in the OI group (p<0.001), but volumetric tissue mineral density was not (p=0.770). Longitudinal OI bone modulus and strength were correlated with volumetric bone mineral density (p≤0.024) but not volumetric tissue mineral density (p≥0.099). Results indicate that cortical bone in children with severe OI yields at the same strain as normal bone, and that their decreased bone material strength is associated with reduced volumetric bone mineral density. These results will enable the advancement of fracture risk assessment capability in children with severe OI. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Femoral revision with impaction allografting and an uncemented femoral component

    DEFF Research Database (Denmark)

    Nickelsen, T N; Erenbjerg, M; Retpen, J B

    2008-01-01

    A technique for uncemented revision of the femoral component which combines impaction allografting and the use of a long-stemmed proximally coated titanium prostheses (Bimetric, Biomet Inc.) is described. The results after a mean follow-up of 112 months are reported. From 1991 to 1995 femoral...... implants 88% had no pain, 10% had slight pain and only 2% had severe pain. Thirty-eight patients had radiographic signs of remodelling of the graft and/or cortical repair. In cases with a successful outcome, the results have been encouraging in relation to clinical performance, regeneration of bone...

  19. Optimization of Ecg Gating in Quantitative Femoral Angiography

    International Nuclear Information System (INIS)

    Nilsson, S.; Berglund, I.; Erikson, U.; Johansson, J.; Walldius, G.

    2003-01-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase

  20. Optimization of Ecg Gating in Quantitative Femoral Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, S.; Berglund, I.; Erikson, U. [Univ. Hospital, Uppsala (Sweden). Dept. of Oncology, Radiology and Clinical Immunology; Johansson, J.; Walldius, G. [Karolinska Hospital, Stockholm (Sweden). King Gustav V Research Inst.

    2003-09-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase.

  1. [Ex vivo microCT analysis of possible microfractures of the femoral head during implantation of a cementless hip resurfacing femoral component].

    Science.gov (United States)

    Lerch, M; Olender, G; von der Höh, N; Thorey, F; von Lewinski, G; Meyer-Lindenberg, A; Windhagen, H; Hurschler, C

    2009-01-01

    Microfractures of the femoral head during implantation of the femoral components are suspected to be a cause of fractures at the implant/neck junction which represent a common failure mode in hip resurfacing arthroplasty. Callus formation observed in femoral head retrievals suggests the occurrence of microfractures inside the femoral head, which might be inadvertently caused by the surgeon during implantation. The aim of this biomechanical study was to analyse whether or not the implantation of a cementless femoral component hip resurfacing system causes microfractures in the femoral head. After the preparation of 20 paired human cadaveric femoral heads, the cementless femoral component ESKA Typ BS (ESKA Implants GmbH & Co., Lübeck) was implanted on 9 specimens with an impaction device that generates 4.5 kN impaction force. On 9 specimens the femoral component was implanted by hand. One head was used as a fracture model, 1 specimen served as control without manipulation. The femoral component used for impaction was equipped with hinges to enable its removal without further interfering with the bone stock. Specimens were scanned with a microCT device before and after impaction and the microCT datasets before and after impaction were compared to identify possible microfractures. Twenty strikes per hand or with the impaction device provided sufficient implant seating. Neither the macroscopic examination nor the 2-dimensional microCT analysis revealed any fractures of the femoral heads after impaction. At least macroscopically and in the 2-dimensional microCT analysis, implantation of the cementless hip resurfacing femoral component ESKA Typ BS with 4.5 kN or by hand does not seem to cause fractures of the femoral head. Georg Thieme Verlag KG Stuttgart, New York.

  2. A Morphological Insight of the Femoral Vein

    Directory of Open Access Journals (Sweden)

    Ferreira AH

    2015-10-01

    Full Text Available A total of 13 cadavers (12 men and 1 women of different age group were used for the study with the purpose to determine the prevalence of femoral vein duplication. Lower limb regions (26 sides were carefully dissected as per the standard dissection procedure. Femoral vein (unitruncular was found in 96.15% of specimen. Bitruncular configurations (total bifidity was found in a male cadaver of 75 years of age (3.85%. In the right lower limb, 6.5 cms below the inguinal ligament the femoral vein - lateral ramus received the lateral circumflex femoral vein, and the medial circumflex femoral vein, and the lateral and medial ramii formed a common venous trunk. Knowledge of the truncular venous variations is important to recognize and avoid potential errors in diagnosis of deep venous thrombosis of the femoral vein, in the case of an occluded duplicated trunk.

  3. Subtrochanteric Femoral Fracture during Trochanteric Nailing for the Treatment of Femoral Shaft Fracture

    OpenAIRE

    Yun, Ho Hyun; Oh, Chi Hun; Yi, Ju Won

    2013-01-01

    We report on three cases of subtrochanteric femoral fractures during trochanteric intramedullary nailing for the treatment of femoral shaft fractures. Trochanteric intramedullary nails, which have a proximal lateral bend, are specifically designed for trochanteric insertion. When combined with the modified insertion technique, trochanteric intramedullary nails reduce iatrogenic fracture comminution and varus malalignment. We herein describe technical aspects of trochanteric intramedullary nai...

  4. Femoral shaft fractures

    International Nuclear Information System (INIS)

    Bender, C.E.; Campbell, D.C. II

    1985-01-01

    The femur is the longest, largest, and strongest bone in the body. Because of its length, width, and role as primary weight-bearing bone, it must tolerate the extremes of axial loading and angulatory stresses. Massive musculature envelopes the femur. This masculature provides abundant blood supply to the bone, which also allows great potential for healing. Thus, the most significant problem relating to femoral shaft fractures is not healing, but restoration of bone length and alignment so that the femoral shaft will tolerate the functional stresses demanded of it

  5. Thermoluminescence dosimetry materials: properties and uses

    International Nuclear Information System (INIS)

    McKeever, S.W.S.; Moscovitch, M.; Townsend, P.D.

    1995-01-01

    This book selects a range of the most popular thermoluminescence dosemeter (TLD) materials in use today and provides a critical account of their thermoluminescence (TL) and dosimetric properties. The information provided includes in-depth discussions of TL mechanisms, including an account of luminescence properties, and relevant information regarding dosimetric characteristics. The book is intended for those involved in TLD materials research, and for technicians and workers involved in the practical application of these materials in TL dosimetry. The advent of modern spectroscopic methods for measuring TL emission spectra (the so-called ''3-D'' presentation) seemed to the authors to be an invitation to compile such spectra for all the major TLD materials. Further consideration led to an expansion of the initial idea to include a compilation of dosimetric properties. One intention is to provide a synopsis of the TL and dosimetric properties of the most widely used TLD materials currently available and to form a link between the solid state defect properties of these materials and their actual dosimetric properties. A second intention is to provide a solid framework from which future studies of TLD materials could be launched. Too often in the past research into TLD materials has been haphazard, to say the least. By illustrating the links between solid state physics and the radiation dosimetry properties of these materials the book points to the future and to the pressing need for enhanced research on TLD materials. (Author)

  6. Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.

    Science.gov (United States)

    Cross, Michael B; Nam, Denis; Mayman, David J

    2012-10-01

    Over the last several years, a trend towards increasing femoral head size in total hip arthroplasty to improve stability and impingement free range of motion has been observed. The specific questions we sought to answer in our review were: (1) What are the potential advantages and disadvantages of metal-on-metal, ceramic-on-ceramic, and metal-on-polyethylene bearings? (2) What is effect that femoral head size has on joint kinematics? (3) What is the effect that large femoral heads have on bearing surface wear? A PubMed search and a review of 2012 Orthopaedic Research Society abstracts was performed and articles were chosen that directly answered components of the specific aims and that reported outcomes with contemporary implant designs or materials. A review of the literature suggests that increasing femoral head size decreases the risk of postoperative dislocation and improves impingement free range of motion; however, volumetric wear increases with large femoral heads on polyethylene and increases corrosion of the stem in large metal-on-metal modular total hip arthroplasty (THA); however, the risk of potentially developing osteolysis or adverse reactions to metal debris respectively is still unknown. Further, the effect of large femoral heads with ceramic-on-ceramic THA is unclear, due to limited availability and published data. Surgeons must balance the benefits of larger head size with the increased risk of volumetric wear when determining the appropriate head size for a given patient.

  7. Subchondral insufficiency fractures of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Davies, M.; Cassar-Pullicino, V.N. [Department of Radiology, Robert Jones and Agnes Hunt Orthopaedic and District Hospital, Oswestry, SY10 7AG, Shropshire (United Kingdom); Darby, A.J. [Department of Pathology, Robert Jones and Agnes Hunt Orthopaedic and District Hospital, Oswestry, SY10 7AG, Shropshire (United Kingdom)

    2004-02-01

    The aim of this study was to increase awareness of, and to show the variable clinical and radiological features of, subchondral insufficiency fractures of the femoral head. The clinical and radiological findings in 7 patients with subchondral insufficiency fractures of the femoral head were reviewed retrospectively. The diagnosis was confirmed histologically in 4 patients. Radiographs were performed in all patients, MRI in 5 and scintigraphy in 4 patients. Radiographs showed varying degrees of femoral head collapse in 4 patients. In the remaining 3 patients radiographs showed a normal femoral head, regional osteoporosis and focal sclerosis, respectively. Magnetic resonance imaging showed a low-signal band on T1- and T2-weighted images in the subchondral bone adjacent or parallel to the articular surface associated with bone marrow oedema. Scintigraphy showed increased uptake in the femoral head. Insufficiency fractures of the femoral head are easily overlooked or confused with avascular necrosis and, when there is significant joint destruction, osteoarthritis. Unsuspected insufficiency fracture of the femoral head can lead to significant and rapid loss of bone stock in osteoporotic patients waiting for arthroplasty for osteoarthritis. Increased awareness of this condition will hopefully lead to earlier diagnosis and a successful outcome of conservative treatment. (orig.)

  8. Systemic effects of zoledronic acid in children with traumatic femoral head avascular necrosis and Legg-Calve-Perthes disease

    DEFF Research Database (Denmark)

    Johannesen, Jesper; Briody, Julie; McQuade, Mary

    2009-01-01

    Background: Intravenous bisphosphonate therapy is associated with preservation of femoral head sphericity and congruence in 77% of children with traumatic avascular necrosis. The aim was to describe the systemic effects of intravenous zoledronic acid (ZA) on bone and mineral metabolism in otherwise...... normal children and adolescents with femoral head AVN. Material and methods: 37 children (age 10.8+/-2.76 years) diagnosed with avascular necrosis AVN (Slipped Capital Femoral Epiphysis (SCFE), N=20 or Legg-Calve-Perthes disease (LCPD), N=17) were treated with at least 12 months of ZA. Bone mineral...

  9. Case report: AVN of the femoral head five year follow-up of the combination of ipsilateral femoral neck and sub-trochanteric fracture.

    Science.gov (United States)

    Zhang, Wei; Zhu, Feng; Dong, Hanqing; Xu, Yaozeng

    2016-04-01

    To our knowledge, the type of combination of ipsilateral femoral neck and sub-trochanteric fracture is rare. And the long term follow-up is seldom been reported. A 60 year old woman suffered from a traffic accident. We gave her the intramedullary nail treatment for the combination of ipsilateral femoral neck and sub-trochanteric fracture, and the fracture indeed cured after one year and there is no clue of necrosis of the femoral head, but after 5 years, there is an evidence of necrosis of the femoral head. Combination of ipsilateral femoral neck and sub-trochanteric fracture should be kept in mind. Patients with this unusual fracture should be kept under surveillance for longer than might be thought currently to be necessary for there is a possibility of necrosis of the femoral head, even a nondisplaced femoral neck fracture.

  10. Fracturing of revision of a cobalt-chrome femoral head after fracturing of a ceramic femoral head, with diffuse metallosis. Case report

    Directory of Open Access Journals (Sweden)

    Pedro Miguel Dantas Costa Marques

    2013-04-01

    Full Text Available We presente a case of a fracture of a cobalt-chrome femoral head after revision of a hip total prosthesis with ceramic femoral head fracture. During surgery we found the cobalt-chrome femoral head fracture, wear of the polyethylene and massive metallosis in muscular and cartilaginous tissue. Both femoral stem and acetabular cup were stable and without apparent wearing. After surgical debridement, we promoted the substitution of the femoral head and the acetabular polyethylene by similar ones. After 12 months of follow-up, the patient has no pain complaints, function limit or systemic signs associated with malign metallosis

  11. Femoral shaft bowing in the coronal plane has more significant effect on the coronal alignment of TKA than proximal or distal variations of femoral shape.

    Science.gov (United States)

    Kim, Jong-Min; Hong, Soo-Heon; Kim, Jong-Min; Lee, Bum-Sik; Kim, Dong-Eun; Kim, Kyung-Ah; Bin, Seong-Il

    2015-07-01

    The aim of this study was to determine (1) variations in the shape of the proximal, middle, and distal femur in a series of Korean patients who had undergone total knee arthroplasty (TKA), (2) the preoperative relationship between these three parameters and the distal valgus cutting angle referenced off the femoral intramedullary guide, and (3) whether there was any relationship between femoral bowing and variations in the shape of the proximal or distal femur in the coronal plane. The preoperative long-standing anteroposterior radiographs of 316 consecutive osteoarthritis patients who underwent primary TKA from 2009 to 2011 were examined. The femoral neck shaft angle, the femoral shaft bowing angle, and the mechanical lateral distal femoral angle were measured to assess the shape of the proximal, middle, and distal femur, respectively. The valgus cutting angle of the femur was defined as the angle between the distal anatomical and mechanical axes of the femur. The study population showed large variations in femoral shape. The mean femoral intramedullary guide angle was 6.5° ± 1.3° (range: 4°-13°). The femoral shaft bowing angle was the factor that showed the strongest correlation with this angle (P shaft angle showed no correlation (n.s.). The femoral shaft bowing angle showed a weak correlation with the mechanical lateral distal femoral angle (P = 0.001), but was not significantly correlated with the femoral neck shaft angle (n.s.). Apparent femoral bowing (>3° of lateral or medial bowing) was found in 42 (13.3 %) of cases (37 cases of lateral bowing and five of medial bowing). Cases with lateral apparent femoral bowing >3° had a distal cutting angle of 8.6° ± 2.2° relative to the femoral intramedullary guide. The femoral intramedullary guide angle was mainly influenced by femoral shaft bowing among femoral deformities in the coronal plane. Therefore, to increase the accuracy of distal femoral cut during TKA, it is necessary to confirm femoral

  12. Slipped capital femoral epiphysis: A modern treatment protocol

    Directory of Open Access Journals (Sweden)

    Slavković Nemanja

    2009-01-01

    Full Text Available The treatment of a patient with slipped capital femoral epiphysis begins with an early diagnosis and accurate classification. On the basis of symptom duration, clinical findings and radiographs, slipped capital femoral epiphysis is classified as pre-slip, acute, acute-on-chronic and chronic. The long-term outcome of slipped capital femoral epiphysis is directly related to severity and the presence or absence of avascular necrosis and/or chondrolysis. Therefore, the first priority in the treatment of slipped capital femoral epiphysis is to avoid complications while securing the epiphysis from further slippage. Medical treatment of patients with acute and acute-on-chronic slipped capital femoral epiphysis, as well as those presented in pre-slip stage, is the safest, although time-consuming. Manipulations, especially forced and repeated, are not recommended due to higher avascular necrosis risk. The use of intraoperative fluoroscopy to assist in the placement of internal fixation devices has markedly increased the success of surgical treatment. Controversy remains as to whether the proximal femoral epiphysis in severe, chronic slipped capital femoral epiphysis should be realigned by extracapsular osteotomies or just fixed in situ. The management protocol for slipped capital femoral epiphysis depends on the experience of the surgeon, motivation of the patient and technical facilities.

  13. Kinetic examination of femoral bone modeling in broilers.

    Science.gov (United States)

    Prisby, R; Menezes, T; Campbell, J; Benson, T; Samraj, E; Pevzner, I; Wideman, R F

    2014-05-01

    Lameness in broilers can be associated with progressive degeneration of the femoral head leading to femoral head necrosis and osteomyelitis. Femora from clinically healthy broilers were dissected at 7 (n = 35, 2), 14 (n = 32), 21 (n = 33), 28 (n = 34), and 42 (n = 28) d of age, and were processed for bone histomorphometry to examine bone microarchitecture and bone static and dynamic properties in the secondary spongiosa (IISP) of the proximal femoral metaphysis. Body mass increased rapidly with age, whereas the bone volume to tissue volume ratio remained relatively consistent. The bone volume to tissue volume ratio values generally reflected corresponding values for both mean trabecular thickness and mean trabecular number. Bone metabolism was highest on d 7 when significant osteoblast activity was reflected by increased osteoid surface to bone surface and mineralizing surface per bone surface ratios. However, significant declines in osteoblast activity and bone formative processes occurred during the second week of development, such that newly formed but unmineralized bone tissue (osteoid) and the percentages of mineralizing surfaces both were diminished. Osteoclast activity was elevated to the extent that measurement was impossible. Intense osteoclast activity presumably reflects marked bone resorption throughout the experiment. The overall mature trabecular bone volume remained relatively low, which may arise from extensive persistence of chondrocyte columns in the metaphysis, large areas in the metaphysis composed of immature bone, destruction of bone tissue in the primary spongiosa, and potentially reduced bone blood vessel penetration that normally would be necessary for robust development. Delayed bone development in the IISP was attributable to an uncoupling of osteoblast and osteoclast activity, whereby bone resorption (osteoclast activity) outpaced bone formation (osteoblast activity). Insufficient maturation and mineralization of the IISP may contribute

  14. Three-dimensional magnetic resonance imaging analysis of hip morphology in the assessment of femoral acetabular impingement

    International Nuclear Information System (INIS)

    Kavanagh, E.C.; Read, P.; Carty, F.; Zoga, A.C.; Parvizi, J.; Morrison, W.B.

    2011-01-01

    Aim: To determine a possible association between femoral-acetabular impingement (FAI) volume and the development of labral tear using a three-dimensional (3D) model reconstruction of the acetabulum and the femoral head. Materials and methods: Magnetic resonance arthrography images of the hip in 42 patients with pain and suspected labral tear were acquired using a 1.5 T MRI machine. Using 3D analysis software, outlines of the acetabular cup and femoral head were drawn and 3D reconstruction obtained. To control for differences in patient size, ratios of acetabulum : femoral head volume (AFV) and acetabulum : femoral head surface area (AFA) were used for analysis. The association between volume of acetabulum : femoral head and FAI was investigated using ANOVA analysis. Results: There were 19 men and 23 women with a mean age of 39 years (range 18-78 years). The average AFV was 0.64 (range 0.37-1.05, SD 0.16) and AFA was 0.73 (range 0.36-1.26, SD 0.23). Herniation pit was significantly associated with a small AFV. Conclusion: Femoral neck herniation pits are associated with a low AFV. Gross volume and surface area ratios do not appear to correlate with labral tears or cartilage loss. This technique will enable more advanced analysis of morphological variations associated with FAI.

  15. Frequency of ipsilateral femoral neck fractures in patients with ...

    African Journals Online (AJOL)

    Background: Ipsilateral associated femoral neck and shaft fractures are reported to occur in 2.5-6% of all femoral shaft fractures. Objective: To establish the frequency of ipsilateral femoral neck fractures amongst all patients presenting with femoral shaft fractures in Mulago Hospital. Methodology: This was a descriptive ...

  16. Tribological changes in the articular cartilage of a human femoral head with avascular necrosis.

    Science.gov (United States)

    Seo, Eun-Min; Shrestha, Suman K; Duong, Cong-Truyen; Sharma, Ashish Ranjan; Kim, Tae-Woo; Vijayachandra, Ayyappan; Thompson, Mark S; Cho, Myung Guk; Park, Sungchan; Kim, Kwanghoon; Park, Seonghun; Lee, Sang-Soo

    2015-06-29

    The present study evaluated the tribological properties of the articular cartilage surface of the human femoral head with postcollapse stage avascular necrosis (AVN) using atomic force microscopy. The cartilage surface in the postcollapse stage AVN of the femoral head was reported to resemble those of disuse conditions, which suggests that the damage could be reversible and offers the possibilities of success of head-sparing surgeries. By comparing the tribological properties of articular cartilage in AVN with that of osteoarthritis, the authors intended to understand the cartilage degeneration mechanism and reversibility of AVN. Human femoral heads with AVN were explanted from the hip replacement surgery of four patients (60-83 years old). Nine cylindrical cartilage samples (diameter, 5 mm and height, 0.5 mm) were sectioned from the weight-bearing areas of the femoral head with AVN, and the cartilage surface was classified according to the Outerbridge Classification System (AVN0, normal; AVN1, softening and swelling; and AVN2, partial thickness defect and fissuring). Tribological properties including surface roughness and frictional coefficients and histochemistry including Safranin O and lubricin staining were compared among the three groups. The mean surface roughness Rq values of AVN cartilage increased significantly with increasing Outerbridge stages: Rq = 137 ± 26 nm in AVN0, Rq = 274 ± 49 nm in AVN1, and Rq = 452 ± 77 nm in AVN2. Significant differences in Rq were observed among different Outerbridge stages in all cases (p AVN0, μ = 0.143 ± 0.025 in AVN1, and μ = 0.171 ± 0.039 in AVN2. Similarly to the statistical analysis of surface roughness, significant statistical differences were detected between different Outerbridge stages in all cases (p AVN. The underlying mechanism of these results can be related to proteoglycan loss within the articular cartilage that is also observed in osteoarthritis. With regard to the tribological properties, the

  17. Femoral neck-shaft angle in extra-capsular proximal femoral fracture fixation; does it make a TAD of difference?

    Science.gov (United States)

    Walton, N P; Wynn-Jones, H; Ward, M S; Wimhurst, J A

    2005-11-01

    The effect of femoral neck-shaft angle and implant type on the accuracy of lag screw placement in extra-capsular proximal femoral fracture fixation was investigated. Radiographs of all extra-capsular proximal femoral fractures seen in one unit over 18 months were reviewed. Of 399 cases, 307 (237 female, 70 male) were included in the study as they had no contra-lateral proximal femoral metal work. Femoral neck-shaft angle (NSA) of the uninjured hip and magnification adjusted tip-apex distance (TAD) of femoral head lag screw were measured. Type of fixation implant was 135 degrees classic hip screw (CHS) (n=144) or 130 degrees intra-medullary hip screw (IMHS) (n=163). Mean contra-lateral NSA was 130.2 degrees (112.9--148 degrees ) and 64 patients (58 female, 6 male) had a NSA TAD was 18.7 mm (5.8--43.8mm) and 88.9% of cases had a TAD of less than 25 mm. TAD values were significantly greater using an IMHS if NSA was 125 degrees (p=0.028). This was not the case with the CHS. The use of the 130 degrees -IMHS in patients with a NSA 125 degrees and caution is advocated when using this device in such cases.

  18. Planning corrective osteotomy of the femoral bone using three-dimensional modeling. Part II

    Directory of Open Access Journals (Sweden)

    Vladimir E. Baskov

    2017-10-01

    Full Text Available Introduction. Three-dimensional (3D modeling and prototyping are increasingly being used in various branches of surgery for planning and performing surgical interventions. In orthopedics, this technology was first used in 1990 for performing knee-joint surgery. This was followed by the development of protocols for creating and applying individual patterns for navigation in the surgical interventions for various bones. Aim. The study aimed to develop a new 3D method for planning and performing corrective osteotomy of the femoral bone using an individual pattern and to identify the advantages of the proposed method in comparison with the standard method of planning and performing surgical intervention. Materials and methods. A new method for planning and performing corrective osteotomy of the femoral bone in children with various pathologies of the hip joint is presented. The outcomes of planning and performing corrective osteotomy of the femoral bone in 27 patients aged 5 to 18 years (32 hip joints with congenital and acquired deformity of the femoral bone were analyzed. Conclusion. The use of computer 3D modeling for planning and implementing corrective interventions on the femoral bone improves the treatment results owing to an almost perfect performance accuracy achieved by the minimization of possible human errors reduction in the surgery duration; and reduction in the radiation exposure for the patient.

  19. Incidence of Avascular Necrosis of the Femoral Head After Intramedullary Nailing of Femoral Shaft Fractures

    Science.gov (United States)

    Kim, Ji Wan; Oh, Jong-Keon; Byun, Young-Soo; Shon, Oog-Jin; Park, Jai Hyung; Oh, Hyoung Keun; Shon, Hyun Chul; Park, Ki Chul; Kim, Jung Jae; Lim, Seung-Jae

    2016-01-01

    Abstract The goal of this study was to determine the incidence of avascular necrosis of the femoral head (AVNFH) after intramedullary nailing of femoral shaft fractures and to identify risk factors for developing AVNFH. We retrospectively reviewed all patients with femoral shaft fractures treated with antegrade intramedullary nailing at 10 institutions. Among the 703 patients enrolled, 161 patients were excluded leaving 542 patients in the study. Average age was 42.1 years with average follow-up of 26.3 months. Patient characteristics and fracture patterns as well as entry point of femoral nails were identified and the incidence of AVNFH was investigated. Patients were divided into 2 groups according to open versus closed physis, open versus closed fractures, and age (<20 versus ≥20 years). Overall incidence of AVNFH was 0.2% (1 of 542): the patient was 15-year-old boy. Of 25 patients with open physis, the incidence of AVNFH was 4%, whereas none of 517 patients with closed physis developed AVNFH (P < 0.001). The incidence of AVNFH in patients aged < 20 versus ≥20 years was 1.1% (1 of 93) and 0.0% (0 of 449), respectively (P = 0.172), which meant that the incidence of AVNFH was 0% in adult with femur shaft fracture. Of 61 patients with open fractures, the incidence of AVNFH was 0%. The number of cases with entry point at the trochanteric fossa or tip of the greater trochanter (GT) was 324 and 218, respectively, and the incidence of AVNFH was 0.3% and 0.0%, respectively (P = 0.412). In patients aged ≥20 years with isolated femoral shaft fracture, there was no case of AVNFH following antegrade intramedullary nailing regardless of the entry point. Therefore, our findings suggest that the risk of AVNFH following antegrade femoral nailing is extremely low in adult patients. PMID:26844518

  20. Avascular necrosis of the femoral head after osteosynthesis of femoral neck fracture.

    Science.gov (United States)

    Min, Byung-Woo; Kim, Sung-Jin

    2011-05-18

    The reported incidence of avascular necrosis after femoral neck fracture fixation varies widely, and there is no consensus regarding its risk factors. We evaluated the incidence of avascular necrosis of the femoral head with the use of contemporary techniques for femoral neck fracture fixation. We then sought to determine what potential risk factors influenced the development of avascular necrosis.Between 1990 and 2005, one hundred sixty-three intracapsular femoral neck fractures in 163 patients were treated with internal fixation at our level-I trauma center. All patients were monitored until conversion to total hip arthroplasty or for a minimum of 2 years postoperatively. Ten patients (10 hips) died and 7 patients (7 hips) were lost to follow-up. The remaining 146 patients (146 hips) had a mean 5.2 years of follow-up (range, 3 months to 17 years). The incidence of avascular necrosis was 25.3% (37 hips). The average time to diagnosis of avascular necrosis was 18.8 months (range, 3-47 months). Patient sex, age, interval from injury to surgery, and mechanism of injury were statistically not associated with the development of avascular necrosis. The quality of fracture reduction, adequacy of fixation, degree of displacement, and comminution of the posterior cortex were significantly associated. After we controlled for patient and radiographic characteristics, multivariate analyses indicated that the important predictors for avascular necrosis are poor reduction (odds ratio=13.889) and initial displacement of the fracture (odds ratio=4.693). Copyright 2011, SLACK Incorporated.

  1. Measuring anteversion in the femoral neck from routine radiographs

    International Nuclear Information System (INIS)

    Hermann, K.L.; Egund, N.

    1998-01-01

    Purpose: To describe a new method for measuring femoral neck anteversion (FNA) that requires only one lateral radiograph of the knee in addition to routine radiographs of the hip for evaluation of total hip replacement; and to compare the proposed method with FNA measurement by means of 3D CT. Material and Methods: In 18 femoral specimens, radiographic examinations of the hip and knee, in three different rotational positions, and one CT examination were made, and the measurements of FNA were compared. Similarly, in 38 patients with 40 total hip replacements, measurements form routine radiographic examinations of the hip and knee and from CT examinations were compared. The accuracy and reproducibility of the FNA measurements produced by this proposed method were calculated. Results: Accuracy and reproducibility were 2 and 2 for the proposed method in the femoral specimen study, and accuracy was 4 in the hip patient study. The proposed method had a minor flaw that was caused almost solely by differences in knee size at inward rotation of the femur. Conclusion: FNA measurement can be made from a routine radiographic examination of the hip and a lateral view of the knee. This method achieves an acceptable level of accuracy and reproducibility. (orig.)

  2. Femoral neck buttressing: a radiographic and histologic analysis

    International Nuclear Information System (INIS)

    Dixon, T.; Benjamin, J.; Lund, P.; Graham, A.; Krupinski, E.

    2000-01-01

    Objective. To examine the incidence, radiographic and histologic findings of medial femoral neck buttressing in a consecutive group of patients undergoing total hip arthroplasty.Design. Biomechanical parameters were evaluated on standard anteroposterior pelvic radiographs of 113 patients prior to hip replacement surgery. Demographic information on all patients was reviewed and histologic evaluation was performed on specimens obtained at the time of surgery.Results. The incidence of medial femoral neck buttressing was found to be 50% in a consecutive series of patients undergoing total hip arthroplasty. The incidence was slightly higher in women (56% vs 41%). Patients with buttressing had increased neck-shaft angles and smaller femoral neck diameters than were seen in patients without buttressing. Histologic evaluation demonstrated that the buttress resulted from deposition bone by the periosteum on the femoral neck in the absence of any evidence of femoral neck fracture.Conclusion. It would appear that femoral neck buttressing occurs in response to increased joint reactive forces seen at the hip being transmitted through the femoral neck. The increased joint reactive force can be related to the increased neck shaft angle seen in patients with buttressing. (orig.)

  3. Angiographic analysis of avascular necrosis of a femoral head -selective angiography of medial femoral circumflex artery-

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Kyung Nam; Yoon, Yup; Lee, Sun Wha; Lim, Jae Hoon [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1991-07-15

    The degree of anatomical revascularization of a necrotic femoral head and traumatic hip would provide information about treatment and prognosis. The authors analyzed the vascular changes of femoral head among unilateral avascular necrosis, bilateral avascular necrosis, and traumatic hips. Forty - four patients with avascular necrosis and 19 patients with traumatic hips were examined by selective angiography of the medial femoral circumflex artery. In the traumatic hip cases, 12 (63%) showed occlusion, 2 (11%) hypertrophy of the capsular branches, and 5 ( 26 % ) were normal . In the avascular necrosis cases, 15 (25%) showed occlusion, 39 (67%) had hypertrophy of the capsular branches, and 4 (7%) had normal findings. Hypertrophy of the superior capsular branch of the medial femoral circumflex artery is more frequently observed in avascular necrosis than in traumatic hip. Bilateral avascular necrosis reveals more frequent incidences than unilateral cases. Selective angiography could help in the therapy plan and also provide information about the contralateral side.

  4. Angiographic analysis of avascular necrosis of a femoral head -selective angiography of medial femoral circumflex artery-

    International Nuclear Information System (INIS)

    Ryu, Kyung Nam; Yoon, Yup; Lee, Sun Wha; Lim, Jae Hoon

    1991-01-01

    The degree of anatomical revascularization of a necrotic femoral head and traumatic hip would provide information about treatment and prognosis. The authors analyzed the vascular changes of femoral head among unilateral avascular necrosis, bilateral avascular necrosis, and traumatic hips. Forty - four patients with avascular necrosis and 19 patients with traumatic hips were examined by selective angiography of the medial femoral circumflex artery. In the traumatic hip cases, 12 (63%) showed occlusion, 2 (11%) hypertrophy of the capsular branches, and 5 ( 26 % ) were normal . In the avascular necrosis cases, 15 (25%) showed occlusion, 39 (67%) had hypertrophy of the capsular branches, and 4 (7%) had normal findings. Hypertrophy of the superior capsular branch of the medial femoral circumflex artery is more frequently observed in avascular necrosis than in traumatic hip. Bilateral avascular necrosis reveals more frequent incidences than unilateral cases. Selective angiography could help in the therapy plan and also provide information about the contralateral side

  5. Risk stratification for avascular necrosis of the femoral head after internal fixation of femoral neck fractures by post-operative SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sang Won; Oh, Min Young; Yoon, Seok Ho; Kim, Jin Soo; Chang, Jae Suk; Ryu, Jin Sook [Asan Medical CenterUniversity of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, Ji Wan [Dept. of Orthopedic Surgery, Haeundae Paik Hospital, Inje University, Busan (Korea, Republic of)

    2017-03-15

    Avascular necrosis (AVN) of the femoral head is a major complication after internal fixation of a femoral neck fracture and determines the functional prognosis. We investigated postoperative bone single-photon emission computed tomography/computed tomography (SPECT/CT) for assessing the risk of femoral head AVN. We retrospectively reviewed 53 consecutive patients who underwent bone SPECT/CT within 2 weeks of internal fixation of a femoral neck fracture and follow-up serial hip radiographs over at least 12 months. Nine patients developed femoral head AVN. In 15 patients who showed normal uptake on immediate postoperative SPECT/CT, no AVN occurred, whereas 9 of 38 patients who showed cold defects of the femoral head later developed AVN. The negative predictive value of immediate postoperative SPECT/CT for AVN was 100 %, whereas the positive predictive value was 24 %. Among 38 patients with cold defects, 1 developed AVN 3 months postoperatively. A follow-up bone SPECT/CT was performed in the other 37 patients at 2–10 months postoperatively. The follow-up bone SPECT/CT revealed completely normalized femoral head uptake in 27, partially normalized uptake in 8, and persistent cold defects in 2 patients. AVN developed in 3.7 % (1/27), 62.5 % (5/8), and 100 % (2/2) of each group, respectively. According to the time point of imaging, radiotracer uptake patterns of the femoral head on postoperative bone SPECT/CT indicate the risk of AVN after internal fixation of femoral neck fractures differently. Postoperative bone SPECT/CT may help orthopedic surgeons determine the appropriate follow-up of these patients.

  6. Risk stratification for avascular necrosis of the femoral head after internal fixation of femoral neck fractures by post-operative SPECT/CT

    International Nuclear Information System (INIS)

    Han, Sang Won; Oh, Min Young; Yoon, Seok Ho; Kim, Jin Soo; Chang, Jae Suk; Ryu, Jin Sook; Kim, Ji Wan

    2017-01-01

    Avascular necrosis (AVN) of the femoral head is a major complication after internal fixation of a femoral neck fracture and determines the functional prognosis. We investigated postoperative bone single-photon emission computed tomography/computed tomography (SPECT/CT) for assessing the risk of femoral head AVN. We retrospectively reviewed 53 consecutive patients who underwent bone SPECT/CT within 2 weeks of internal fixation of a femoral neck fracture and follow-up serial hip radiographs over at least 12 months. Nine patients developed femoral head AVN. In 15 patients who showed normal uptake on immediate postoperative SPECT/CT, no AVN occurred, whereas 9 of 38 patients who showed cold defects of the femoral head later developed AVN. The negative predictive value of immediate postoperative SPECT/CT for AVN was 100 %, whereas the positive predictive value was 24 %. Among 38 patients with cold defects, 1 developed AVN 3 months postoperatively. A follow-up bone SPECT/CT was performed in the other 37 patients at 2–10 months postoperatively. The follow-up bone SPECT/CT revealed completely normalized femoral head uptake in 27, partially normalized uptake in 8, and persistent cold defects in 2 patients. AVN developed in 3.7 % (1/27), 62.5 % (5/8), and 100 % (2/2) of each group, respectively. According to the time point of imaging, radiotracer uptake patterns of the femoral head on postoperative bone SPECT/CT indicate the risk of AVN after internal fixation of femoral neck fractures differently. Postoperative bone SPECT/CT may help orthopedic surgeons determine the appropriate follow-up of these patients

  7. Macroscopic properties of model disordered materials

    International Nuclear Information System (INIS)

    Knackstedt, M.A.; Roberts, A.P.

    1996-01-01

    Disordered materials are ubiquitous in nature and in industry. Soils, sedimentary rocks, wood, bone, polymer composites, foams, catalysts, gels, concretes and ceramics have properties that depend on material structure. Present techniques for predicting properties are limited by the theoretical and computational difficulty of incorporating a realistic description of material structure. A general model for microstructure was recently proposed by Berk [Berk, Phys.Rev.A, 44 5069 (1991)]. The model is based on level cuts of a Gaussian random field with arbitrary spectral density. The freedom in specifying the parameters of the model allows the modeling of physical materials with diverse morphological characteristics. We have shown that the model qualitatively accounts for the principal features of a wider variety of disordered materials including geologic media, membranes, polymer blends, ceramics and foams. Correlation functions are derived for the model microstructure. From this characterisation we derive mechanical and conductive properties of the materials. Excellent agreement with experimentally measured properties of disordered solids is obtained. The agreement provides a strong hint that it is now possible to correlate effective physical properties of porous solids to microstructure. Simple extensions to modelling properties of non-porous multicomponent blends; metal alloys, ceramics, metal/matrix and polymer composites are also discussed

  8. Ipsilateral femoral neck and shaft fractures: An overlooked association

    International Nuclear Information System (INIS)

    Daffner, R.H.; Riemer, B.L.; Butterfield, S.L.

    1991-01-01

    A total of 304 patients with injuries to the femoral shaft and ipsilateral hip presented between 1984 and 1990. Some 253 of them suffered fractures of the femoral shaft and dislocated hips or fractures of the acetabulum, and 51 of these sustained fractures of the femoral shaft and neck or trochanteric region. All of the trochanteric injuries were demonstrated on the initial radiographs. However, in 11 of the patients with combined femoral shaft and neck fractures, the diagnosis was delayed by as much as 4 weeks. This delay related to the fact that these fractures tended not to separate in the initial evaluation period and that there was external rotation of the proximal femoral fragment due to the femoral shaft fracture. (orig./GDG)

  9. Ipsilateral femoral neck and shaft fractures: An overlooked association

    Energy Technology Data Exchange (ETDEWEB)

    Daffner, R.H. (Dept. of Diagnostic Radiology, Allegheny General Hospital, Pittsburgh, PA (USA) Medical Coll. of Pennsylvania, Pittsburgh, PA (USA)); Riemer, B.L.; Butterfield, S.L. (Dept. of Orthopedic Surgery, Allegheny General Hospital, Pittsburgh, PA (USA) Medical Coll. of Pennsylvania, Pittsburgh, PA (USA))

    1991-05-01

    A total of 304 patients with injuries to the femoral shaft and ipsilateral hip presented between 1984 and 1990. Some 253 of them suffered fractures of the femoral shaft and dislocated hips or fractures of the acetabulum, and 51 of these sustained fractures of the femoral shaft and neck or trochanteric region. All of the trochanteric injuries were demonstrated on the initial radiographs. However, in 11 of the patients with combined femoral shaft and neck fractures, the diagnosis was delayed by as much as 4 weeks. This delay related to the fact that these fractures tended not to separate in the initial evaluation period and that there was external rotation of the proximal femoral fragment due to the femoral shaft fracture. (orig./GDG).

  10. Vein Patch Closure Using Below the Knee Greater Saphenous Vein for Femoral Endarterectomy Procedures is Not Always a Safe Choice

    Directory of Open Access Journals (Sweden)

    M. Berner

    Full Text Available : Background: The complication of vein patch rupture is well described after carotid patch angioplasty; however, there is a paucity of data about the safety of vein patch closure in the setting of femoral endarterectomy. Methods/results: From May 2012 to May 2015, 115 femoral endarterectomies with patch closure were performed. A patch rupture occurred in three cases (2.6% with a mortality rate of 66% (2/3. In all cases the greater saphenous vein below the knee was used as patch material. Discussion/conclusion: Vein patches, particularly from small calibre veins, should be excluded in femoral endarterectomy procedures as they pose a substantial risk of rupture. Keywords: Angioplasty, Patch rupture, Femoral artery, Patch, Great saphenous vein

  11. Augmentation of proximal femoral nail in unstable trochanteric fractures

    Directory of Open Access Journals (Sweden)

    Gadegone Wasudeo M.

    2017-01-01

    Full Text Available Introduction: Biomechanically proximal femoral nail (PFN is a better choice of implant, still it is associated with screw breakage, cut out of screw through femoral head, Z effect, reverse Z effect, and lateral migration of screws. The purpose of this study is to evaluate the results of augmented PFN in terms of prevention of postoperative complications and failure rates in unstable trochanteric fractures. Material and methods: We carried out a prospective study of 82 cases with unstable trochanteric femoral fractures from April 2010 to December 2015. Forty-two females and 40 males in the age group between 58 and 81 years were included in this study. There were 45 cases of AO 31 A2 (2.2, 2.3 and 37 cases of AO 31 A3 (3.1, 3.2, 3.3. Fractures were fixed by PFN with augmentation by an additional screw from trochanter to inferior quadrant of femoral head or cerclage wire to strengthen the lateral trochanteric wall. Results: The bone healing is observed in all the cases in the mean period of 14.2 weeks. Nine patients developed complications, including lateral migration of neck screws (n = 5, Z effect (n = 1, infection (n = 2, and breakage of distal interlocking bolt in one case. Removal of screws was required in five cases. Patients were followed up for a mean of 8.4 months. At the end of follow-up the Salvati and Wilson hip function was 32 (out of 40 in 88% of patients. Conclusion: The stabilization of lateral trochanteric wall with additional screw or cerclage wire increases the stability of construct.

  12. Femoral component rotation in patellofemoral joint replacement.

    Science.gov (United States)

    van Jonbergen, Hans-Peter W; Westerbeek, Robin E

    2018-06-01

    Clinical outcomes in patellofemoral joint replacement may be related to femoral component rotation. Assessment of rotational alignment is however difficult as patients with isolated patellofemoral osteoarthritis often have trochlear dysplasia. The use of the medial malleolus as a landmark to guide rotation has been suggested. The purpose of our study was to evaluate this technique with regard to femoral component rotation, and to correlate rotation with clinical outcomes at one-year follow-up. Forty-one knees in 39 patients had patellofemoral joint replacement using the Zimmer Gender-Solutions patellofemoral prosthesis. Intraoperatively, we determined femoral component rotational alignment using an extramedullary rod aimed at the inferior tip of the medial malleolus. Postoperatively, we measured the angle between the femoral component and the anatomical transepicondylar axis using CT. The amount of rotation was correlated with clinical outcomes at one-year follow-up. Forty knees in 38 patients were available for one-year follow-up. Mean femoral component rotation relative to the anatomical transepicondylar axis was 1.4° external rotation (range, -3.8 to 5.7°). We found no statistically significant correlation between femoral component rotation and change from baseline KOOS subscales at one-year follow-up. Our findings show that when using the medial malleolus as a landmark to guide rotation, the femoral component of the patellofemoral prosthesis was oriented in external rotation relative to the anatomical transepicondylar axis in 80% of knees. Our study did not show a relation between the amount of external rotation and clinical outcomes. Level III. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Clinical study on 44 cases of femoral hernia

    International Nuclear Information System (INIS)

    Yamamoto, Ryo; Shinozaki, Hiroharu; Kase, Kenichi; Kobayashi, Kenji; Sasaki, Junichi

    2012-01-01

    Femoral hernia is a surgical disease that is frequently associated with incarceration and necessitates emergency surgery. However, there are only a few studies referred which have compared emergency and elective surgery for femoral hernias. We retrospectively reviewed the clinical characteristics of patients diagnosed as having femoral hernia between 2005 and 2009 in our institution. The clinical features of emergency repairs were compared with those of elective ones, and diagnostic values of preoperative diagnostic modalities were studied. The mean age of the patients was 73±12 years. Females comprised 68% of the cases, and right femoral hernias comprised 70% of the cases. Incarceration was associated with 66% of the cases (29 patients), and emergency surgery was performed in 52% of the patients (23 patients). Bowel resection was performed in 32% of the cases (14 patients). The mean age, body temperature, white blood cell (WBC) count, and LDH value were higher in the emergency repairs than in the elective one, and most of the hernias were repaired with McVay's procedure. CT scans had a high diagnostic value in detecting femoral hernias (44%) and incarceration (88%). It was confirmed that femoral hernias were frequently associated with incarceration and CT scan has a high diagnostic value in femoral hernias. (author)

  14. MR evaluation of femoral neck version and tibial torsion

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, James Karl; Dwek, Jerry R. [University of California, San Diego, Children' s Hospital and Health Center, Department of Radiology, San Diego, CA (United States); Pring, Maya E. [Rady Children' s Hospital, Department of Pediatric Orthopedic Surgery, San Diego, CA (United States)

    2012-01-15

    Abnormalities of femoral neck version have been associated with a number of hip abnormalities in children, including slipped capital femoral epiphysis, proximal femoral focal deficiency, coxa vara, a deep acetabulum and, rarely, developmental dysplasia of the hip. Orthopedic surgeons also are interested in quantifying the femoral neck anteversion or retroversion in children especially to plan derotational osteotomies. Historically, the angle of femoral version and tibial torsion has been measured with the use of radiography and later by CT. Both methods carry with them the risks associated with ionizing radiation. Techniques that utilize MR are used less often because of the associated lengthy imaging times. This article describes a technique using MRI to determine femoral neck version and tibial torsion with total scan times of approximately 10 min. (orig.)

  15. 1D Piezoelectric Material Based Nanogenerators: Methods, Materials and Property Optimization.

    Science.gov (United States)

    Li, Xing; Sun, Mei; Wei, Xianlong; Shan, Chongxin; Chen, Qing

    2018-03-23

    Due to the enhanced piezoelectric properties, excellent mechanical properties and tunable electric properties, one-dimensional (1D) piezoelectric materials have shown their promising applications in nanogenerators (NG), sensors, actuators, electronic devices etc. To present a clear view about 1D piezoelectric materials, this review mainly focuses on the characterization and optimization of the piezoelectric properties of 1D nanomaterials, including semiconducting nanowires (NWs) with wurtzite and/or zinc blend phases, perovskite NWs and 1D polymers. Specifically, the piezoelectric coefficients, performance of single NW-based NG and structure-dependent electromechanical properties of 1D nanostructured materials can be respectively investigated through piezoresponse force microscopy, atomic force microscopy and the in-situ scanning/transmission electron microcopy. Along with the introduction of the mechanism and piezoelectric properties of 1D semiconductor, perovskite materials and polymers, their performance improvement strategies are summarized from the view of microstructures, including size-effect, crystal structure, orientation and defects. Finally, the extension of 1D piezoelectric materials in field effect transistors and optoelectronic devices are simply introduced.

  16. Correlation between baseline femoral neck marrow status and the development of femoral head osteonecrosis in corticosteroid-treated patients: A longitudinal study by MR imaging

    International Nuclear Information System (INIS)

    Vande Berg, Bruno C.; Gilon, Raphael; Malghem, Jacques; Lecouvet, Frederic; Depresseux, Genevieve; Houssiau, Frederic A.

    2006-01-01

    Objective: To test the hypothesis that the development of corticosteroid (CS)-associated femoral head osteonecrosis (ON) is influenced by baseline femoral neck marrow status. Patients and methods: The population consisted of 20 untreated patients with a newly diagnosed rheumatic disease in whom a standardized CS regimen was planned. Before CS treatment, baseline femoral neck marrow status was determined by magnetic resonance (MR) imaging on T1-weighted images (proportion of surface area of femoral neck and intertrochanteric area occupied by fatty marrow; index of marrow conversion [IMC]) and on a quantitative MR sequence (bulk T1 values of femoral head and neck). The presence of ON was assessed by coronal T1-weighted MR images of the hips at 6 and 12 months. Results: None of the patients suffered from ON at baseline. Four patients (20%) developed bilateral femoral head ON at 6 months. The mean percentage of fat marrow in the femoral neck before treatment was significantly higher in ON-positive than in ON-negative patients (p = 0.0025). The mean baseline femoral neck IMC value, which parallels the degree of red to yellow marrow conversion, was higher in ON-positive than in ON-negative patients (p = 0.089). The mean baseline bulk T1 value of the femoral neck (but not of the femoral head), which inversely correlates with the amount of fat marrow, was significantly shorter in ON-positive than in ON-negative patients (p = 0.0298). Conclusion: The development of CS-associated femoral head ON is correlated with a high fat content in the proximal femur before CS therapy

  17. Herniography off femoral, obturator and perineal hernias

    International Nuclear Information System (INIS)

    Ekberg, O.; Nordblom, I.; Fork, F.T.; Gullmo, A.

    1985-01-01

    Positive contrast herniography was used in the workup of 550 patients with unclear groin pain. The majority of these patients had rather characteristic hernias of indirect, direct or femoral type. However, now and then diagnostic problems arose. A femoral hernia may look like a direct or even obturator hernia. There is also a variety of multilocular femoral hernias and other types. A femoral hernia may be present together with other hernias in the ipsilateral or contralateral groin. Obturator hernias are usually small but are always confined to the obturator canal laterally in the obturator foramen. Abnormalities in the pouch of Douglas may include a deep rectogenital pouch, diverticula and true herniations. These uncommon herniographic findings are described and discussed. (orig.) [de

  18. Successful disinfection of femoral head bone graft using high hydrostatic pressure.

    Science.gov (United States)

    van de Sande, Michiel A J; Bovée, Judith V M G; van Domselaar, Mark; van Wijk, Marja J; Sanders, Ingrid; Kuijper, Ed

    2017-12-20

    The current standard for sterilization of potentially infected bone graft by gamma irradiation and thermal or chemical inactivation potentially deteriorates the biomechanical properties of the graft. We performed an in vitro experiment to evaluate the use of high hydrostatic pressure (HHP); which is widely used as a disinfection process in the food processing industry, to sterilize bone grafts. Four femoral heads were divided into five parts each, of which 16 were contaminated (in duplicate) with 10 5 -10 7  CFU/ml of Staphylococcus epidermidis, Bacillus cereus, or Pseudomonas aeruginosa or Candida albicans, respectively. Of each duplicate, one sample was untreated and stored similarly as the treated sample. The remaining four parts were included as sterile control and non-infected control. The 16 parts underwent HHP at the high-pressure value of 600 MPa. After HHP, serial dilutions were made and cultured on selective media and into enrichment media to recover low amounts of microorganism and spores. Three additional complete femoral heads were treated with 0, 300 and 600 MPa HHP respectively for histological evaluation. None of the negative-control bone fragments contained microorganisms. The measured colony counts in the positive-control samples correlated excellent with the expected colony count. None of the HHP treated bone fragments grew on culture plates or enrichment media. Histological examination of three untreated femoral heads showed that the bone structure remained unchanged after HHP. Sterilizing bone grafts by high hydrostatic pressure was successful and is a promising technique with the possible advantage of retaining biomechanical properties of bone tissue.

  19. Computer navigation experience in hip resurfacing improves femoral component alignment using a conventional jig

    Directory of Open Access Journals (Sweden)

    Zachary Morison

    2013-01-01

    Full Text Available Background:The use of computer navigation has been shown to improve the accuracy of femoral component placement compared to conventional instrumentation in hip resurfacing. Whether exposure to computer navigation improves accuracy when the procedure is subsequently performed with conventional instrumentation without navigation has not been explored. We examined whether femoral component alignment utilizing a conventional jig improves following experience with the use of imageless computer navigation for hip resurfacing. Materials and Methods:Between December 2004 and December 2008, 213 consecutive hip resurfacings were performed by a single surgeon. The first 17 (Cohort 1 and the last 9 (Cohort 2 hip resurfacings were performed using a conventional guidewire alignment jig. In 187 cases, the femoral component was implanted using the imageless computer navigation. Cohorts 1 and 2 were compared for femoral component alignment accuracy. Results:All components in Cohort 2 achieved the position determined by the preoperative plan. The mean deviation of the stem-shaft angle (SSA from the preoperatively planned target position was 2.2° in Cohort 2 and 5.6° in Cohort 1 ( P = 0.01. Four implants in Cohort 1 were positioned at least 10° varus compared to the target SSA position and another four were retroverted. Conclusions: Femoral component placement utilizing conventional instrumentation may be more accurate following experience using imageless computer navigation.

  20. STUDY OF AGE INCIDENCE AND SYMMETRY IN NON - TRAUMATIC AVASCULAR NECROSIS OF FEMORAL HEAD

    Directory of Open Access Journals (Sweden)

    Harinath

    2015-10-01

    Full Text Available INTRODUCION: Avascular necrosis of the femoral head is an increasingly common cause of musculoskeletal disability, and it poses a major diagnostic and therapeutic challenge. The aim of diagnostic imaging procedures in avascular femoral head necrosis is to provide the patient with a stage - adapted therapy. The aim of this paper is to present the age incidence and symmetricity of involvement of the non - traumatic avascular necrosis of femoral head. MATERIALS AND METHODS: This is a prospective observational study done durin g January 2013 to June 2013.The study included a total 30 patients referred to the Department of Radiology, Kurnool medical college, Kurnool, for X ray pelvis with both hips. 10 patients out of them were further investigated with MRI pelvis. RESULTS: More than half of the patients (72.6 % were within the age groups 30 - 50 years with male to female ratio of about 4:1. 60% of patients showed bilateral involvement, 20 % showed right femoral head and 20 % showed left femoral head involvement. CONCLUSION: We con clude that disease affects mostly adults within their 3rd and 5th decade and majority of the patients are being men with bilateral involvement. Our study results are comparable with previous studies. Hence we recommend MRI both hips for early identificatio n of AVN changes in asymptomatic contra-lateral hip or normal appearing hip on X-Ray.

  1. Trochanteric entry femoral nails yield better femoral version and lower revision rates-A large cohort multivariate regression analysis.

    Science.gov (United States)

    Yoon, Richard S; Gage, Mark J; Galos, David K; Donegan, Derek J; Liporace, Frank A

    2017-06-01

    Intramedullary nailing (IMN) has become the standard of care for the treatment of most femoral shaft fractures. Different IMN options include trochanteric and piriformis entry as well as retrograde nails, which may result in varying degrees of femoral rotation. The objective of this study was to analyze postoperative femoral version between three types of nails and to delineate any significant differences in femoral version (DFV) and revision rates. Over a 10-year period, 417 patients underwent IMN of a diaphyseal femur fracture (AO/OTA 32A-C). Of these patients, 316 met inclusion criteria and obtained postoperative computed tomography (CT) scanograms to calculate femoral version and were thus included in the study. In this study, our main outcome measure was the difference in femoral version (DFV) between the uninjured limb and the injured limb. The effect of the following variables on DFV and revision rates were determined via univariate, multivariate, and ordinal regression analyses: gender, age, BMI, ethnicity, mechanism of injury, operative side, open fracture, and table type/position. Statistical significance was set at pregression analysis revealed that a lower BMI was significantly associated with a lower DFV (p=0.006). Controlling for possible covariables, multivariate analysis yielded a significantly lower DFV for trochanteric entry nails than piriformis or retrograde nails (7.9±6.10 vs. 9.5±7.4 vs. 9.4±7.8°, pregression analysis. However, this is not to state that the other nail types exhibited abnormal DFV. Translation to the clinical impact of a few degrees of DFV is also unknown. Future studies to more in-depth study the intricacies of femoral version may lead to improved technology in addition to potentially improved clinical outcomes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Bilateral femoral neck fractures following pelvic irradiation

    International Nuclear Information System (INIS)

    Mitsuda, Kenji; Nishi, Hosei; Oba, Hiroshi

    1977-01-01

    Over 300 cases of femoral neck fractures following radiotherapy for intrapelvic malignant tumor have been reported in various countries since Baensch reported this disease in 1927. In Japan, 40 cases or so have been reported, and cases of bilateral femoral neck fractures have not reached to ten cases. The authors experienced a case of 75 year-old female who received radiotherapy for cancer of the uterus, and suffered from right femoral neck fracture 3 months after and left femoral neck fracture one year and half after. As clinical symptoms, she had not previous history of trauma in bilateral femurs, but she complained of a pain in a hip joint and of gait disturbance. The pain in left femoral neck continued for about one month before fracture was recognized with roentgenogram. As histopathological findings, increase of fat marrow, decrease of bone trabeculae, and its marked degeneration were recognized. Proliferation of some blood vessels was found out, but thickness of the internal membrane and thrombogenesis were not recognized. Treatment should be performed according to degree of displacement of fractures. In this case, artificial joint replacement surgery was performed to the side of fracture of this time, because this case was bilateral femoral neck fractures and the patient had received artificial head replacement surgery in the other side of fracture formerly. (Tsunoda, M.)

  3. [Treatment of avascular necrosis of femoral head after femoral neck fracture with pedicled iliac bone graft].

    Science.gov (United States)

    Wang, Benjie; Zhao, Dewei; Guo, Lin; Yang, Lei; Li, Zhigang; Cui, Daping; Tian, Fengde; Liu, Baoyi

    2011-05-01

    To explore the effectiveness of pedicled iliac bone graft transposition for treatment of avascular necrosis of femoral head (ANFH) after femoral neck fracture. Between June 2002 and December 2006, 22 cases (22 hips, 16 left hips and 6 right hips) of ANFH after femoral neck fracture were treated with iliac bone graft pedicled with ascending branch of the lateral femoral circumflex vessels. There were 18 males and 4 females with an age range from 28 to 48 years (mean, 37.5 years). The time from injury to internal fixation was 2-31 days, and all fractures healed within 12 months after internal fixation. The ANFH was diagnosed at 15-40 months (mean, 22 months) after internal fixation. The ANFH duration was 3-11 months (mean, 8 months). According to Association Research Circulation Osseous (ARCO) staging system, 2 hips were classified as stage IIa, 3 hips as stage IIb, 3 hips as stage IIc, 3 hips as stage IIIa, 7 hips as stage IIIb, and 4 hips as stage IIIc. The preoperative Harris hip score (HHS) was 64.10 +/- 5.95. All incisions healed by first intention and the patients had no complication of lung embolism, sciatic nerve injury, lower limb deep venous thrombosis, and numbness and pain of donor site. All patients were followed up 2.5 to 6.3 years (mean, 4.8 years). The fracture healing time was 8-12 months, and no femoral neck fracture recurred. The HHS was 90.20 +/- 5.35 at last follow-up, showing significant difference when compared with the preoperative value (t = -18.447, P = 0.000). The hip function were excellent in 11 hips, good in 10 hips, fair in 1 hip, and the excellent and good rate was 95.5%. Four hips were radiographically progressed in ARCO staging, 18 hips remained stable with a stable rate of 81.8%. Pedicled iliac bone graft transposition is an ideal option for treatment of ANFH after internal fixation of femoral neck fracture for the advantages of femoral head revascularization, sufficient cancellous bone supply, and relatively simple procedure.

  4. Magnetic resonance imaging of the femoral head necrosis

    Energy Technology Data Exchange (ETDEWEB)

    Narita, Shinya; Asada, Kanji; Yoshida, Kenjiro and others

    1986-06-01

    Ten patients with avascular femoral head necrosis and four normal adults were examined by magnetic resonance imaging (MRI). In addition, the relationship between MRI and pathophysiology of three operated-on avascular femoral heads was evaluated. The medullary cavities of the normal femoral heads had a strong signal intensity on the saturation recovery (SR) image due to fat marrow, and the T/sub 1/ relaxation time was 160 +- 11 msec. In avascular femoral head necrosis, the necrotic area had a low signal intensity on the SR image and a prolonged T/sub 1/ relaxation time, while the reactive fibrous area had more prolonged T/sub 1/ relaxation time. For these reasons, MRI was found to show the pathological changes of avascular femoral head necrosis and can be expected to be useful for making early diagnoses and operation planning.

  5. Magnetic resonance imaging of the femoral head necrosis

    International Nuclear Information System (INIS)

    Narita, Shinya; Asada, Kanji; Yoshida, Kenjiro

    1986-01-01

    Ten patients with avascular femoral head necrosis and four normal adults were examined by magnetic resonance imaging (MRI). In addition, the relationship between MRI and pathophysiology of three operated-on avascular femoral heads was evaluated. The medullary cavities of the normal femoral heads had a strong signal intensity on the saturation recovery (SR) image due to fat marrow, and the T 1 relaxation time was 160 ± 11 msec. In avascular femoral head necrosis, the necrotic area had a low signal intensity on the SR image and a prolonged T 1 relaxation time, while the reactive fibrous area had more prolonged T 1 relaxation time. For these reasons, MRI was found to show the pathological changes of avascular femoral head necrosis and can be expected to be useful for making early diagnoses and operation planning. (author)

  6. Femoral component loosening after hip resurfacing arthroplasty

    International Nuclear Information System (INIS)

    Zustin, Jozef; Sauter, Guido; Hahn, Michael; Morlock, Michael M.; Ruether, Wolfgang; Amling, Michael

    2010-01-01

    Before the re-introduction of the current generation of total hip resurfacing arthroplasty, component loosening and osteolysis were of great concern to the orthopaedic community. Early, mid- and long-term clinical results are encouraging, but component loosening still exists. Macroscopic, contact radiographic and histopathological analyses after undecalcified preparation of bone tissue specimens were performed. To investigate the frequency and morphological patterns of the loosening of the femoral component, we analysed a series of 190 retrieved femoral remnants that were revised for aseptic failures. Thirty-five (18.4%) hips were revised for clinical and/or radiographic loosening of the femoral component. Pseudoarthrosis (n = 17; median in situ time: 16 weeks, interquartile range [IQR]: 9 to 34), collapsed osteonecrosis (n = 5; median in situ time: 79 weeks, IQR: 63 to 97), cement-socket debonding (n = 3; median in situ time: 89 weeks, IQR: 54 to 97) and at later follow-up bone-cement loosening (n = 10; median in situ time: 175 weeks; IQR 112 to 198; p =0.005) were distinct patterns of the femoral remnant-implant loosening. Fibrocartilaginous metaplasia of interface bone trabeculae (n = 38; median in situ time: 61 weeks, IQR: 32 to 138) was strongly associated with femoral component loosening (p = 0.009). Both the trabecular hyperosteoidosis (n = 32; median in situ time: 71 weeks, IQR 50 to 129) and excessive intraosseous lymphocyte infiltration (n = 12; median in situ time: 75 weeks, IQR 51 to 98) at the bone-cement interface correlated strongly with fibrocartilaginous metaplasia (p = 0.001 and p = 0.016 respectively) and all three lesions were associated with the female gender (p = 0.021, p = 0.009, and p = 0.051). Femoral component loosening at early follow-up was mostly caused by pathological changes of the femoral remnant bone tissue: pseudoarthrosis and collapsed osteonecrosis. Fibrocartilaginous metaplasia was frequently observed in hips with femoral

  7. Anomalies of ossification in the posterolateral femoral condyle: assessment by MRI

    Energy Technology Data Exchange (ETDEWEB)

    Nawata, K.; Teshima, Ryota; Morio, Yasuo; Hagino, Hiroshi [Department of Orthopaedic Surgery, Faculty of Medicine, Tottori University, Yonaga (Japan)

    1999-10-01

    Background. Anomalies of ossification in the lower femoral epiphysis are often radiographically indistinguishable from juvenile osteochondritis dissecans. Objective. To clarify the MRI characteristics of the anomalies of ossification in the posterolateral femoral condyle that distinguish it from juvenile osteochondritis dissecans. Materials and methods. We retrospectively examined the medical records, plain radiographs (n = 4), MRI (n = 4) and follow-up MRI (n = 2) of four boys (age 8-11 years) with anomalies of ossification in the posterolateral femoral condyle. Results. Plain radiography showed symmetrical marginal irregularity of the posterolateral femoral condyles of both knees. These lesions were asymptomatic, and the areas of irregular radiographic appearances reduced in size or disappeared without treatment within a mean observation period of 3.5 months. MRI showed a clearly demarcated low-intensity islet with the same signal intensity as subchondral bone (which was considered to be an accessory ossification nucleus) in a high-signal area in which the signal intensity was equal to that of normal articular cartilage. The areas observed as radiolucent zones on plain radiography were visualised at the same signal intensity as articular cartilage, and were continuous with articular cartilage on MRI; thus they were regarded as uncalcified cartilage. These MR findings are different from MR images of osteochondritis dissecans. Conclusions. MRI is considered to be the most effective non-invasive diagnostic method for these two conditions. (orig.) With 3 figs., 1 tab., 10 refs.

  8. Properties and characterization of modern materials

    CERN Document Server

    Altenbach, Holm

    2017-01-01

    This book focuses on robust characterization and prediction methods for materials in technical applications as well as the materials’ safety features during operation. In particular, it presents methods for reliably predicting material properties, an aspect that is becoming increasingly important as engineering materials are pushed closer and closer to their limits to boost the performance of machines and structures. To increase their engineering value, components are now designed under the consideration of their multiphysical properties and functions, which requires much more intensive investigation and characterization of these materials. The materials covered in this monograph range from metal-based groups such as lightweight alloys, to advanced high-strength steels and modern titanium alloys. Furthermore, a wide range of polymers and composite materials (e.g. with micro- and nanoparticles or fibres) is covered. The book explores methods for property prediction from classical mechanical characterization-...

  9. Avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Kokubo, Takeshi; Takatori, Yoshio; Kamogawa, Morihide; Nakamura, Toshitaka; Ninomiya, Setsuo; Yoshikawa, Kohki; Itai, Yuji; Iio, Masahiro; Mitamura, Tadayuki

    1990-01-01

    T1-weighted MR images of thirty-six hips in 25 patients with avascular necrosis of the femoral head were obtained two to five times during the course of 2 to 26 months. We investigated these MR images in the light of the chronological change and compared them with plain radiographs. MR images changes in 16 femoral head; in general, the abnormal low intensity area in the femoral head reduced in extent and the internal high intensity area became smaller of disappeared. Thirteen femoral heads among them became more flattened on plain radiographs in the same period. It is noted that four different zones are defined in the femoral head after bone necrosis takes place: the dead bone marrow, the dead marrow which still contains fat, the reactive interface and the hyperemic bone marrow. In T1-weighted MR images, the dead bone marrow, the reactive interface and the hyperemic bone marrow are demonstrated as low intensity area, while the dead marrow containing fat may remain high in intensity. On the basis of this knowledge of histopathology and MR images of this disease, we suggest that reduction of the abnormal low intensity area and disappearance of the internal high intensity area on MR images can be regarded as diminution of hyperemia in the living bone marrow and loss of fat in the dead bone marrow, respectively. (author)

  10. CT study of avascular necrosis of femoral head in adults

    International Nuclear Information System (INIS)

    Liu Jihua; Du Yuqing; Xu Aide

    2000-01-01

    Objective: To study the early and new CT signs of avascular necrosis of femoral head in adults. Methods: The CT scans of 127 cases with this condition were analyzed. Results: There were 90 hip joints with femoral head normal in shape, including 67 femoral heads with only high-density sclerosis and 23 ones with high-density and low-density areas. In 111 hip joints, the femoral head was depressed and manifested purely high-density sclerosis in 25 and mixed-density areas in 86. Air-filled cysts appeared in 43 femoral heads. In follow-up cases, the changes in shape and density of femoral head followed some rules. Conclusion: Purely high-density sclerosis is an early sign and is of great diagnostic value combined with its special shape. Air in femoral heads is also a sign of the disease

  11. Benign aggressive lesions of femoral head and neck: Is salvage possible?

    Directory of Open Access Journals (Sweden)

    Yogesh Panchwagh

    2018-01-01

    Full Text Available Background: Benign aggressive bone lesions of the femoral head and neck are mostly seen in young adults and warrant treatment for pain, impending fracture or established fracture, and disease clearance. It becomes challenging to treat them effectively while attempting salvage of the femoral head and yet achieving long term disease control with minimum complications. We describe our technique and experience in dealing with these lesions which can achieve the above-mentioned goals and can be easily replicated. Materials and Methods: We analyzed 15 cases of surgically treated, biopsy-proven benign, locally aggressive lesions affecting the femoral head and neck in skeletally mature individuals. All cases were treated with extended curettage through anterolateral modified Smith–Petersen approach along with tricortical iliac crest bone graft (combined with fibular graft in some cases reconstruction with or without suitable internal fixation. Results: All, except one, patients were available for follow up. The age ranged from 18 to 43 years and the follow up ranged between 24 and 124 months (average 78 months. These included aneurysmal bone cysts (9, giant cell tumors (4, and fibrous dysplasia (2. The indication was pain (8, with impending (2 or established pathological neck femur fracture (5. In all cases, there was satisfactory healing of lesion and timely rehabilitation. Nonunion, avascular necrosis or local recurrences were not seen. The MSTS functional score was good or excellent in all (range 26–29, average 28. Conclusion: Benign aggressive lesions affecting femoral head and neck in young and middle-aged adults pose a treatment challenge. A sturdy, lasting reconstruct with acceptable functional outcome and minimal recurrence rate can be achieved by salvaging the femoral head and neck using curettage and reconstruction, obviating the need for replacement at such an early age.

  12. Morphometric analysis of rat femoral vessels under a video magnification system

    Directory of Open Access Journals (Sweden)

    Rui Sergio Monteiro de Barros

    Full Text Available Abstract The right femoral vessels of 80 rats were identified and dissected. External lengths and diameters of femoral arteries and femoral veins were measured using either a microscope or a video magnification system. Findings were correlated to animals’ weights. Mean length was 14.33 mm for both femoral arteries and femoral veins, mean diameter of arteries was 0.65 mm and diameter of veins was 0.81 mm. In our sample, rats’ body weights were only correlated with the diameter of their femoral veins.

  13. Study of the anatomical position of the femoral nerve by magnetic resonance imaging in patients with fractured neck of femur: relevance to femoral nerve block.

    LENUS (Irish Health Repository)

    Mehmood, Shehzad

    2012-01-31

    STUDY OBJECTIVE: To determine the anatomical location of the femoral nerve in patients who have sustained fracture of the neck of femur, and its relevance to femoral nerve block technique. DESIGN: Prospective, observational clinical study. SETTING: Orthopedic and Radiology departments of a regional hospital. SUBJECTS: 10 consecutive adult ASA physical status II and III patients (mean age, 78.5 yrs) and 4 adult healthy volunteers. INTERVENTIONS: A T1 magnetic resonance imaging scan was performed of both upper thighs in patients and healthy volunteers successfully. MEASUREMENTS: The distance (mm) between the midpoint of the femoral artery and the midpoint of the femoral nerve, and the distance of the femoral nerve from the skin was measured at the mid-inguinal ligament, the pubic tubercle, and at the mid-inguinal crease. Data are shown as means (SD). Differences between both sides were compared using paired Student\\'s t-tests. P < 0.05 was significant. MAIN RESULTS: In patients the mean distance (mm) between the midpoint of the femoral nerve from the midpoint of femoral artery at the mid-inguinal crease on the fractured and non-fractured sides was 10.7 and 11.0, respectively (P = 0.87). The mean distance (mm) between the midpoint of the femoral nerve from the midpoint of the femoral artery at the mid-inguinal ligament on the fractured and non-fractured sides was 9.64 and 12.5, respectively (P = 0.03). The mean distance (mm) between the midpoint of the femoral nerve from the midpoint of the femoral artery at the pubic tubercle on the fractured and non-fractured sides was 8.74 and 10.49, respectively (P = 0.18). CONCLUSIONS: Blockade of the femoral nerve may be easier to perform at the mid-inguinal crease in patients with fractured neck of femur.

  14. A STUDY OF UNSTABLE INTERTROCHANTERIC FEMORAL FRACTURES TREATED BY TROCHANTERIC FEMORAL NAIL

    Directory of Open Access Journals (Sweden)

    Sreenivasa Neikar

    2017-11-01

    Full Text Available BACKGROUND Intertrochanteric fracture is one of the most common fracture of the hip especially in the elderly. The incidence of intertrochanteric fracture is rising because of the increase in number of elderly population along with superadded osteoporosis. MATERIALS AND METHODS Study included cases of unstable intertrochanteric fractures (AO and OTA Classification 31-A2 and 31-A3 fracture patterns that were operated with the short trochanteric femoral nail, which fitted into the inclusion criteria done in medical college hospital, Vijayanagara Institute of Medical Sciences, Bellary, from February 2015 to September 2016. RESULTS The age distribution was from 40 to 80 years. The largest group of patients were from 61 to 70 years. The average age was 60.5 years. The number of male patients in our series was 20 (66.7% and female was 10 (33.3%. Right side was affected in 11 cases (36.7% and left side in 19 cases (63.3%. Good reduction was achieved in 23 patients (76.7%. Acceptable reduction was achieved in 7 (23.3% patients due to severe comminution. In our study, 25 patients (83.33% had no complications. We encountered one intraoperative complication in the form of greater trochanter splintering, while inserting the nail. In our study, we encountered following postoperative complications. We noticed one case of delayed union, one case of Z effect and 2 cases of varus malunion. CONCLUSION We conclude that short trochanteric femoral nail provides good fixation for unstable intertrochanteric fractures if proper preoperative planning, good reduction and surgical technique are followed leading to high rate of bone union and minimal soft tissue damage especially for Asian patients with relatively small femora.

  15. Materials with complex behaviour II properties, non-classical materials and new technologies

    CERN Document Server

    Oechsner, Andreas

    2012-01-01

    This book reviews developments and trends in advanced materials and their properties; modeling and simulation of non-classical materials and new technologies for joining materials. Offers tools for characterizing and predicting properties and behavior.

  16. Femoroacetabular impingement: bone marrow oedema associated with fibrocystic change of the femoral head and neck junction

    Energy Technology Data Exchange (ETDEWEB)

    James, S.L.J. [Department of Radiology, RNOH Stanmore, Stanmore, Middlesex (United Kingdom) and Department of Radiology, Royal Orthopaedic Hospital, Birmingham (United Kingdom)]. E-mail: jamesslj@email.com; Connell, D.A. [Department of Radiology, RNOH Stanmore, Stanmore, Middlesex (United Kingdom); O' Donnell, P. [Department of Radiology, RNOH Stanmore, Stanmore, Middlesex (United Kingdom); Saifuddin, A. [Department of Radiology, RNOH Stanmore, Stanmore, Middlesex (United Kingdom)

    2007-05-15

    Aim: To describe the association of bone marrow oedema adjacent to areas of fibrocystic change at the femoral head and neck junction in patients with femoroacetabular impingement. Materials and methods: The clinical and imaging findings in six patients with bone marrow oedema adjacent to an area of fibrocystic change at the femoral head and neck junction are presented. There were five males and one female (age range 19-42 years, mean age 34.5 years). Three patients were referred with a clinical suspicion of femoroacetabular impingement, two with suspected osteoid osteoma and one with a clinical diagnosis of sciatica. The volume of bone marrow oedema (grade 1: 0-25%, grade 2: 26-50%, grade 3: 51-75% and grade 4: 76-100% of the femoral neck width), presence of labral and articular cartilage abnormality, joint effusion, and femoral head and neck morphology were recorded. Results: Magnetic resonance imaging (MRI) identified fibrocystic change in the anterolateral aspect of the femoral head and neck junction in all cases (mean size 9 mm, range 5-14 mm, three multilocular and three unilocular cysts). The volume of oedema was variable (one grade 1, two grade 2, one grade 3 and two grade 4). All patients had abnormality of the anterosuperior labrum with five patients demonstrating chondral loss. An abnormal femoral head and neck junction was identified in five patients. Conclusion: The radiological finding of fibrocystic change at the anterosuperior femoral neck with or without bone marrow oedema should prompt the search for femoroacetabular impingement. Bone marrow oedema may rarely be identified adjacent to these areas of cystic change and should be considered in the differential diagnosis of bone marrow oedema in the femoral neck.

  17. Femoroacetabular impingement: bone marrow oedema associated with fibrocystic change of the femoral head and neck junction

    International Nuclear Information System (INIS)

    James, S.L.J.; Connell, D.A.; O'Donnell, P.; Saifuddin, A.

    2007-01-01

    Aim: To describe the association of bone marrow oedema adjacent to areas of fibrocystic change at the femoral head and neck junction in patients with femoroacetabular impingement. Materials and methods: The clinical and imaging findings in six patients with bone marrow oedema adjacent to an area of fibrocystic change at the femoral head and neck junction are presented. There were five males and one female (age range 19-42 years, mean age 34.5 years). Three patients were referred with a clinical suspicion of femoroacetabular impingement, two with suspected osteoid osteoma and one with a clinical diagnosis of sciatica. The volume of bone marrow oedema (grade 1: 0-25%, grade 2: 26-50%, grade 3: 51-75% and grade 4: 76-100% of the femoral neck width), presence of labral and articular cartilage abnormality, joint effusion, and femoral head and neck morphology were recorded. Results: Magnetic resonance imaging (MRI) identified fibrocystic change in the anterolateral aspect of the femoral head and neck junction in all cases (mean size 9 mm, range 5-14 mm, three multilocular and three unilocular cysts). The volume of oedema was variable (one grade 1, two grade 2, one grade 3 and two grade 4). All patients had abnormality of the anterosuperior labrum with five patients demonstrating chondral loss. An abnormal femoral head and neck junction was identified in five patients. Conclusion: The radiological finding of fibrocystic change at the anterosuperior femoral neck with or without bone marrow oedema should prompt the search for femoroacetabular impingement. Bone marrow oedema may rarely be identified adjacent to these areas of cystic change and should be considered in the differential diagnosis of bone marrow oedema in the femoral neck

  18. Avascular osteonecrosis of the femoral condyle after arthroscopic surgery; Osteonecrose aseptique du condyle femoral apres meniscectomie par voie arthroscopique

    Energy Technology Data Exchange (ETDEWEB)

    Al-Kaar, M.; Garcia, J. [Hopital Cantonal Geneve, Geneva (Switzerland); Fritschy, D.; Bonvin, J.C. [Policlinique de Chirurgie, Hopital Cantonal Universitaire, Geneve (Switzerland)

    1997-04-01

    Avascular osteonecrosis of the femoral condyle after arthroscopic surgery. Retrospective review of 10 patients who presented with avascular necrosis of the ipsilateral femoral condyle following arthroscopic meniscectomy (9 medial, 1 lateral). The bone lesions were evaluated by radiography and MRI, which were repeated for few patients. MRI allows earlier diagnosis of avascular necrosis of the femoral condyle and offers an evaluation of extent of the lesions whose evolution is variable: 3 patients required a knee prosthesis, the other 7 patients were treated medically. (authors). 21 refs.

  19. Femoral neck stress fractures (fnsf) in military recruits

    International Nuclear Information System (INIS)

    Majeed, N.U.; Naqvi, A.N.; Majeed, H.

    2012-01-01

    Objective: To identify patterns of Femoral Neck Stress Fractures (FNSF), its presentation and outcome of its treatment in PMA (Pakistan Military Academy) cadets. These findings would help suggest guidelines for their appropriate management. Study design: Case Series Place and duration of study: CMH Abbottabad and CMH Rawalpindi from May 2005 to January 2008. Materials and Methods: Twenty cases (20 hips in 18 patients) of FNSF were included in the study. Only male cadets from Pakistan Military Academy (PMA) were included. Diagnosis was made clinically and was confirmed by radiographs or bone scan. Incomplete fractures were managed conservatively where as complete fractures were fixed surgically. Results: All compression fractures healed conservatively where as tension fractures needed surgical fixation in all the cases, except one where fracture remained incomplete. Rest of tension fractures converted from incomplete fractures to complete fractures and hence needed surgical stabilization. There was no problem of avascular necrosis of femoral head (AVNFH) in any patient. Conclusion: FNSF are uncommon injuries with potentially serious complications and are difficult to diagnose clinically. When diagnosed early and managed appropriately, they carry good prognosis. (author)

  20. Properties of plastic filtration material

    Energy Technology Data Exchange (ETDEWEB)

    Paluch, W.

    1988-01-01

    Discusses properties of filters made of thermoplastic granulated material. The granulated plastic has a specific density of 10.3-10.6 kN/m/sup 3/ and a bulk density of about 6 kN/m/sup 3/. Its chemical resistance to acids, bases and salts is high but is it soluble in organic solvents. Filters made of this material are characterized by a porosity coefficient of 36.5% and a bulk density of 5.7-6.8 kN/m/sup 3/. Physical and mechanical properties of filter samples made of thermoplastic granulated material (50x50x50 mm) were investigated under laboratory conditions. Compression strength and influencing factors were analyzed (ambient temperature, manufacturing technology). Tests show that this filtration material developed by Poltegor is superior to other filtration materials used in Poland.

  1. Magnetic materials fundamentals, products, properties, applications

    CERN Document Server

    Hilzinger, Rainer

    2013-01-01

    At a practical level, this compendium reviews the basics of soft and hard magnetic materials, discusses the advantages of the different processing routes for the exploitation of the magnetic properties and hence assists in proper, fail-safe and economic application of magnetic materials. Essential guidelines and formulas for the calculation of the magnetic and electrical properties, temperature and long-term stability of permanent magnets, of inductive components and magnetic shielding are compiled. Selected fields of application and case studies illustrate the large diversity of technical applications. Application engineers will appreciate the comprehensive compilation of the properties and detailed characteristic curves of modern soft and hard magnetic materials. Materials scientists will enjoy the presentation of the different processing routes and their impact on the magnetic properties and students will profit from the survey from the basics of magnetism down to the applications in inductive components, ...

  2. Finite Element Method for Analysis of Material Properties

    DEFF Research Database (Denmark)

    Rauhe, Jens Christian

    and the finite element method. The material microstructure of the heterogeneous material is non-destructively determined using X-ray microtomography. A software program has been generated which uses the X-ray tomographic data as an input for the mesh generation of the material microstructure. To obtain a proper...... which are used for the determination of the effective properties of the heterogeneous material. Generally, the properties determined using the finite element method coupled with X-ray microtomography are in good agreement with both experimentally determined properties and properties determined using......The use of cellular and composite materials have in recent years become more and more common in all kinds of structural components and accurate knowledge of the effective properties is therefore essential. In this wok the effective properties are determined using the real material microstructure...

  3. Simultaneous avascular necrosis of both medial and lateral femoral condyles

    International Nuclear Information System (INIS)

    Mansberg, R.

    2002-01-01

    Full text: Avascular necrosis (AVN) of a femoral condyle is a common orthopaedic condition. While both medial and lateral femoral condyles may be involved either singly or sequentially the simultaneous occurrence of AVN of both femoral condyles is extremely uncommon. A 57-year-old male is presented who developed the onset of severe left sided knee pain suddenly at rest. Plain and tomographic radiography was unremarkable and a bone scan was performed. Markedly increased vascularity was demonstrated in the left knee with intense osteoblastic activity in the left medial and femoral condyles more marked in the lateral femoral condyle. A diagnosis of AVN of both femoral condyles was made and a MRI exam was performed to confirm this unusual diagnosis. The MRI showed a diffuse increase in intensity bilaterally with subtle bony change in the subarticular bone consistent with AVN more marked in the left lateral femoral condyle. The patients' symptoms resolved with supportive treatment. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  4. Marrow pattern in the proximal femoral metaphysis of patients with osteonecrosis of femoral head and normal subjects: comparison on MR images

    International Nuclear Information System (INIS)

    Chun, Ho Jong; Park, Jeong Mi; Kim, Jee Young; Lim, Gye Yeon; Yang, Po Song; Kim, Euy Neyong; Kim, Choon Yul; Shinn, Kyung Sub

    1996-01-01

    To predict early risk of osteonecrosis of the femoral head by comparison of the bone marrow pattern of the proximal femoral metaphysis(PFM) in normal subjects and patients with osteonecrosis of the femoral head on T1-weighted magnetic resonance(MR) images. The authors retrospectively reviewed T1(TR 525/TE 25 msec) weighted coronal MR images of 67 hips with osteonecrosis and 65 normal hips in 39 patients with osteonecrosis of the femoral head and in 27 normal subjects. On the basis of bright signal intensity of fat, the proportion of remaining hematopoietic marrow in PFM was subdivided into 4 grades (0 to 3) by two radiologists. No evidence of remaining hematopoietic marrow was assigned grade 0, and grades 1, 2 and 3 represented scanty, moderate, and prominent hematopoietic marrow, respectively. Grades 0 and 1 were collectively defined as 'predominantly fatty', grades 2 and 3 as 'predominantly hematopoietic'. The frequency of the predominantly fatty marrow in PFM was analyzed in relation to three age groups (<25, 25-50, 50<) and both sexes. The overall frequency of predominantly fatty marrow in PFM was higher in hips with osteonecrosis than in normal hips (p<0.001). Especially in the male population under the age of 50, the frequency was apparently higher in hips with osteonecrosis, compared with normal hips (p<0.0001). However, the male population aged over 50 or female population showed no statistically significant difference in our series. In proximal femoral metaphysis with osteonecrosis of the femoral head, fatty marrow conversion occurs apparently earlier than in normal subject. T1-weighted MR imaging could therefore be useful in predicting early risk of osteonecrosis of the femoral head because of early fatty marrow conversion of the proximal femoral metaphysis

  5. A micro-architectural evaluation of osteoporotic human femoral heads to guide implant placement in proximal femoral fractures.

    Science.gov (United States)

    Jenkins, Paul J; Ramaesh, Rishikesan; Pankaj, Pankaj; Patton, James T; Howie, Colin R; Goffin, Jérôme M; Merwe, Andrew van der; Wallace, Robert J; Porter, Daniel E; Simpson, A Hamish

    2013-10-01

    The micro-architecture of bone has been increasingly recognized as an important determinant of bone strength. Successful operative stabilization of fractures depends on bone strength. We evaluated the osseous micro-architecture and strength of the osteoporotic human femoral head. 6 femoral heads, obtained during arthroplasty surgery for femoral neck fracture, underwent micro-computed tomography (microCT) scanning at 30 μm, and bone volume ratio (BV/TV), trabecular thickness, structural model index, connection density, and degree of anisotropy for volumes of interest throughout the head were derived. A further 15 femoral heads underwent mechanical testing of compressive failure stress of cubes of trabecular bone from different regions of the head. The greatest density and trabecular thickness was found in the central core that extended from the medial calcar to the physeal scar. This region also correlated with the greatest degree of anisotropy and proportion of plate-like trabeculae. In the epiphyseal region, the trabeculae were organized radially from the physeal scar. The weakest area was found at the apex and peripheral areas of the head. The strongest region was at the center of the head. The center of the femoral head contained the strongest trabecular bone, with the thickest, most dense trabeculae. The apical region was weaker. From an anatomical and mechanical point of view, implants that achieve fixation in or below this central core may achieve the most stable fixation during fracture healing.

  6. Sex-specific functional adaptation of the femoral diaphysis to body composition.

    Science.gov (United States)

    Lacoste Jeanson, Alizé; Santos, Frédéric; Dupej, Ján; Velemínská, Jana; Brůžek, Jaroslav

    2018-03-24

    The human femoral diaphysis is often used to reconstruct loading histories (mobility, activity, body mass). The proximal femur is known to be differentially affected by changes in total fat-mass (FM), fat-free mass (FFM), and body fat percentage (BF%), but the adaptation of the entire diaphysis to body composition has not been thoroughly characterized to date. Understanding how the femoral diaphysis adapts to body components would benefit biomechanical interpretations of the femoral variation and nutrition-related studies. Combining various methods from clinical nutrition, biological anthropology, and geometric morphometrics, we evaluated the correlation of measures taken on the entire femoral diaphysis with estimated FM, FFM, and BF% from 61 CT scans (17 females, 44 males). The sample was predominantly composed of people with obesity. Cortical area of the cross-sections and local cortical thickness showed high correlation with BF% in particular, in females only. The curvature significantly decreased with FM and BF% in both sexes. The lowest correlations are found with FFM. The observed sexual dimorphism is consistent with differing aging processes; cortical bone decreases in females through endosteal resorption while it remains almost constant in males who compensate for endosteal resorption by periosteal apposition on the diaphyseal surface. The functional adaptation to compressive forces indicates a systemic endosteal apposition of bone material with increased BF% and FM in females only. FM and BF% are linked to a straighter femur in both sexes, suggesting an optimization of the resistance to compressive loads by distributing them more linearly along the entire diaphysis. © 2018 Wiley Periodicals, Inc.

  7. Surgery for pathological proximal femoral fractures, excluding femoral head and neck fractures: resection vs. stabilisation.

    Science.gov (United States)

    Zacherl, Max; Gruber, Gerald; Glehr, Mathias; Ofner-Kopeinig, Petra; Radl, Roman; Greitbauer, Manfred; Vecsei, Vilmos; Windhager, Reinhard

    2011-10-01

    Pathological femoral head and neck fractures are commonly treated by arthroplasty. Treatment options for the trochanteric region or below are not clearly defined. The purpose of this retrospective, comparative, double-centre study was to analyse survival and influences on outcome according to the surgical technique used to treat pathological proximal femoral fractures, excluding fractures of the femoral head and neck. Fifty-nine patients with 64 fractures were operated up on between 1998 and 2004 in two tertiary referral centres and divided into two groups. One group (S, n = 33) consisted of patients who underwent intramedullary nailing alone, and the other group (R, n = 31) consisted of patients treated by metastatic tissue resection and reconstruction by means of different implants. Median survival was 12.6 months with no difference between groups. Surgical complications were higher in the R group (n = 7) vs. the S group (n = 3), with no statistically significant difference. Patients with surgery-related complications had a higher survival rate (p = 0.049), as did patients with mechanical implant failure (p = 0.01). Survival scoring systems did not correlate with actual survival. Resection of metastases in patients with pathological fractures of the proximal femur, excluding femoral head and neck fractures, has no influence on survival. Patients with long postoperative survival prognosis are at risk of implant-related complications.

  8. Femoral head vitality after intracapsular hip fracture

    International Nuclear Information System (INIS)

    Stroemqvist, B.

    1983-01-01

    Femoral head vitality before, during and at various intervals from the operation was determined by tetracycline labeling and/or 99 sp (m)Tc-MDP scintimetry. In a three-year follow-up, healing prognosis could be determined by scintimetry 3 weeks from operation; deficient femoral head vitality predicting healing complications and retained vitality predicting uncomplicated healing. A comparison between pre- and postoperative scintimetry indicated that further impairment of the femoral head vitality could be caused by the operative procedure, and as tetracycline labeling prior to and after fracture reduction in 370 fractures proved equivalent, it was concluded that the procedure of osteosynthesis probably was responsible for capsular vessel injury, using a four-flanged nail. The four-flanged nail was compared with a low-traumatic method of osteosynthesis, two hook-pins, in a prospective randomized 14 month study, and the postoperative femoral head vitality was significantly better in the hook-pin group. This was also clearly demonstrated in a one-year follow-up for the fractures included in the study. Parallel to these investigations, the reliability of the methods of vitality determination was found satisfactory in methodologic studies. For clinical purpose, primary atraumatic osteosynthesis, postoperative prognostic scintimetry and early secondary arthroplasty when indicated, was concluded to be the appropriate approach to femoral neck fracture treatment. (Author)

  9. Virtual materials design using databases of calculated materials properties

    International Nuclear Information System (INIS)

    Munter, T R; Landis, D D; Abild-Pedersen, F; Jones, G; Wang, S; Bligaard, T

    2009-01-01

    Materials design is most commonly carried out by experimental trial and error techniques. Current trends indicate that the increased complexity of newly developed materials, the exponential growth of the available computational power, and the constantly improving algorithms for solving the electronic structure problem, will continue to increase the relative importance of computational methods in the design of new materials. One possibility for utilizing electronic structure theory in the design of new materials is to create large databases of materials properties, and subsequently screen these for new potential candidates satisfying given design criteria. We utilize a database of more than 81 000 electronic structure calculations. This alloy database is combined with other published materials properties to form the foundation of a virtual materials design framework (VMDF). The VMDF offers a flexible collection of materials databases, filters, analysis tools and visualization methods, which are particularly useful in the design of new functional materials and surface structures. The applicability of the VMDF is illustrated by two examples. One is the determination of the Pareto-optimal set of binary alloy methanation catalysts with respect to catalytic activity and alloy stability; the other is the search for new alloy mercury absorbers.

  10. Early detection by sup(99m)Tc-Sn-pyrophosphate scintigraphy of femoral head necrosis following medial femoral neck fractures

    International Nuclear Information System (INIS)

    Greiff, J.; Lanng, S.; Hoeilund-Carlsen, P.F.; Karle, A.K.; Uhrenholdt, A.

    1980-01-01

    A selected series of 24 patients with displaced medial femoral neck fracture, treated with closed reduction and osteosynthesis with cancellous bone screws (ASIF), were investigated. During an observation period of 6 to 26 months, serial hip joint scintigraphies were performed and compared with serial X-ray examinations. At the first scintigraphic examination performed on average 5-6 weeks after the fracture, two separate investigators found a decreased amount of activity or no activity in the femoral head of 10 and 8 patients, respectively. At the second scintigraphic examination performed on average 11.1 weeks after the fracture both investigators found no activity or a decreased amount of activity in 8 patients. This figure declined to 7 during the following period, because one patient with decreased activity was recorded as having normal activity 15 months after the fracture. These 7 patients all developed radiological signs of femoral head collapse on average 16.3 months after the fracture (range 5-26 months), whereas their scintigrams displayed decreased or absent tracer uptake on average 1.2 months after the fracture (P<0.01). None of the patients with initially normal or increased uptake later showed decreased or absent uptake during the study and none developed radiological collapse. It may be concluded that absent or decreased uptake of sup(99m)Tc-Sn-pyrophosphate in the femoral head following medial femoral neck fracture indicates femoral head necrosis and a high risk of late segmental collapse, whereas normal or increased uptake implying preserved blood supply means that late segmental collapse will probably never develop. (author)

  11. A biomechanical evaluation of proximal femoral nail antirotation with respect to helical blade position in femoral head: A cadaveric study

    Directory of Open Access Journals (Sweden)

    Jin-Ho Hwang

    2012-01-01

    Full Text Available Objective: Despite new developments in the management of osteoporotic fractures, complications like screw cutout are still found in the fixation of proximal femur fractures even with biomechanically proven better implants like proximal femoral nail antirotation (PFNA. The purpose of this cadaveric study was to investigate the biomechanical stability of this device in relation to two common positions (center-center and inferior-center of the helical blade in the femoral head in unstable trochanteric fractures. Materials and Methods: Eight pairs of human cadaveric femurs were used; in one group [center-center (C-C group], the helical blade of PFNA was fixed randomly in central position both in anteroposterior and lateral view, whereas in the other group it was fixed in inferior one-third position in anteroposterior and in central position in lateral view [inferior-center (I-C group]. Unstable intertrochanteric fracture was created and each specimen was loaded cyclically till load to failure Results: Angular and rotational displacements were significantly higher within the C-C group compared to the I-C group in both unloaded and loaded condition. Loading to failure was higher in the I-C group compared to the C-C group. No statistical significance was found for this parameter. Correlations between tip apex distance, cyclic loading which lead to femoral head displacement, and ultimate load to failure showed a significant positive relationship. Conclusion: The I-C group was superior to the C-C group and provided better biomechanical stability for angular and rotational displacement. This study would be a stimulus for further experimental studies with larger number specimens and complex loading protocols at multicentres.

  12. Evaluation of the Superior Gluteal Nerve During Proximal Femoral Nailing

    Directory of Open Access Journals (Sweden)

    Mehmet Sonmez

    2017-05-01

    Full Text Available Aim: The superior gluteal nerve may be compromised during hip surgery. We retrospectively evaluated the patients who underwent proximal femoral nailing for unstable trochanteric fractures in order to investigate the presence of superior gluteal nerve injury and its clinical findings. Material and Method: Twenty five patients (14 women, 11 men were included in the study who had femoral nailing between January 2004 and March 2010 at Hamidiye Sisli Etfal Training and Research Hospital Department of Orthopaedics. Two different types of nails which have similar designs and surgical techniques were used for fracture fixation. Patients who had a history of cerebrovascular disease, electromyography findings of polyneuropathy, or degenerative vertebral disease were excluded from the study. Patients were evaluated clinically and radiologically. Findings related to acute denervation in the gluteus medius muscle and motor unit action potential changes were accepted as signs of superior gluteal nerve injury. Results: Eight patients were using support during walking and three of these patients had positive Trendelenburg sign, but only one patient had acute denervation signs of the superior gluteal nerve. Discussion: Based on the present study the incidence of iatrogenic nerve injury is a rare complication of proximal femoral nailing. Elderly patients, regardless of whether they have nerve injury, may limp and need to use a walking support.

  13. Femoral Head Avascular Necrosis Is Not Caused by Arthroscopic Posterolateral Femoroplasty.

    Science.gov (United States)

    Rupp, Robert E; Rupp, Sasha N

    2016-05-01

    This study was conducted to identify the risk of avascular necrosis of the femoral head after arthroscopic femoroplasty extending to the posterolateral femoral neck, the source of the primary blood supply to the femoral head. Cam lesions of femoroacetabular impingement are typically anterior along the junction of the femoral head and neck. However, anatomic variations can involve the posterolateral vascular region of the femoral head and neck. Femoroplasty involving this vascular region can lead to injury to the blood supply to the femoral head, with subsequent avascular necrosis. If the posterolateral portion of the cam lesion is preserved, persistent femoroacetabular impingement may occur. A retrospective review identified 112 patients who underwent arthroscopic femoroplasty for femoroacetabular impingement over a 2-year period. Of these patients, 14 had femoroplasty that extended to the posterolateral femoral head. Of this group, 5 had undergone magnetic resonance imaging (MRI) after femoroplasty and the other 9 were contacted to undergo MRI of the hip to evaluate for avascular necrosis. A radiologist and the senior author evaluated all MRI scans specifically for avascular necrosis of the femoral head. All procedures were performed by the senior author. Mean age of the 14 patients (8 women and 6 men) with femoroplasty that extended into the posterolateral vascular region of the femoral head was 44 years (range, 23-69 years). All 14 patients underwent MRI evaluation of the affected hip a mean of 25 months (range, 7-44 months) after femoroplasty. No MRI scans showed evidence of avascular necrosis of the femoral head. Femoroplasty of the posterolateral vascular region of the femoral head is not associated with avascular necrosis. Patients with femoroacetabular impingement and a cam lesion extending to the posterolateral femoral head can undergo femoroplasty of this region without the development of avascular necrosis. [Orthopedics. 2016; 39(3):177-180.]. Copyright

  14. Ossification variants of the femoral condyles are not associated with osteochondritis dissecans

    Energy Technology Data Exchange (ETDEWEB)

    Jans, L., E-mail: lennartjans@hotmail.com [Department of Radiology and Medical Imaging, Ghent University Hospital, De Pintelaan 185, 9000 Gent (Belgium); Jaremko, J., E-mail: jjaremko@gmail.com [Department of Radiology, University of Alberta Hospital, 8440-112 Street, Edmonton T6G 2B7, Alberta (Canada); Ditchfield, M., E-mail: Michael.ditchfield@southernhealth.org.au [Department of Radiology, Monash University Clayton Campus, Wellington Road, Clayton 3800, VIC (Australia); De Coninck, T., E-mail: Tinekedeconinck@ugent.be [Department of Radiology and Medical Imaging, Ghent University Hospital, De Pintelaan 185, 9000 Gent (Belgium); Huysse, W., E-mail: Wouter.huysse@ugent.be [Department of Radiology and Medical Imaging, Ghent University Hospital, De Pintelaan 185, 9000 Gent (Belgium); Moon, A., E-mail: Anna.moon@rch.org.au [Department of Radiology, Royal Children' s Hospital, Flemington Road, Parkville 3052, VIC (Australia); Verstraete, K., E-mail: Koenraad.verstraete@ugent.be [Department of Radiology and Medical Imaging, Ghent University Hospital, De Pintelaan 185, 9000 Gent (Belgium)

    2012-11-15

    Purpose: To determine if ossification variants of the femoral condyles involving the subchondral bone plate are associated with osteochondritis dissecans (OCD). Materials and methods: The prevalence of ossification variants of the unaffected femoral condyle in 116 patients (aged 9-14 years) with unicondylar OCD on MRI (magnetic resonance imaging) of the knee was compared to a control group of 579 patients (aged 9-14 years) without OCD. The evolution of the ossification variants in both groups was studied by reviewing follow-up MR imaging side by side with the baseline study. Results: The prevalence of ossification variants in the unaffected condyle in patients with OCD (12.9%) and in the control group of patients without OCD (12.6%) was similar (p = 0.88). Evolution of ossification variants to OCD was not seen on follow-up MRI examinations. All variants had decreased in size or were no longer visible. Conclusion: Ossification variants of the femoral condyle that involve the subchondral bone plate are not associated with OCD. Clinical relevance statement: Ossification variants are not associated with OCD, indicating that routine MRI follow-up in affected children is not mandatory.

  15. Ossification variants of the femoral condyles are not associated with osteochondritis dissecans

    International Nuclear Information System (INIS)

    Jans, L.; Jaremko, J.; Ditchfield, M.; De Coninck, T.; Huysse, W.; Moon, A.; Verstraete, K.

    2012-01-01

    Purpose: To determine if ossification variants of the femoral condyles involving the subchondral bone plate are associated with osteochondritis dissecans (OCD). Materials and methods: The prevalence of ossification variants of the unaffected femoral condyle in 116 patients (aged 9–14 years) with unicondylar OCD on MRI (magnetic resonance imaging) of the knee was compared to a control group of 579 patients (aged 9–14 years) without OCD. The evolution of the ossification variants in both groups was studied by reviewing follow-up MR imaging side by side with the baseline study. Results: The prevalence of ossification variants in the unaffected condyle in patients with OCD (12.9%) and in the control group of patients without OCD (12.6%) was similar (p = 0.88). Evolution of ossification variants to OCD was not seen on follow-up MRI examinations. All variants had decreased in size or were no longer visible. Conclusion: Ossification variants of the femoral condyle that involve the subchondral bone plate are not associated with OCD. Clinical relevance statement: Ossification variants are not associated with OCD, indicating that routine MRI follow-up in affected children is not mandatory.

  16. Selective arteriography in femoral head fractures

    Energy Technology Data Exchange (ETDEWEB)

    Mannella, P; Galeotti, R; Borrelli, M; Benea, G; Massari, L; Chiarelli, G M

    1986-01-01

    The choice between conservative and radical operation in case of femoral neck fractures is very important because it is the determining factor for a successfull therapy. In case of epiphysial necrosis, an endoprosthesis as well as an osteosynthesis will be carried out. Selective arteriography of the medical circumflex artery represents the most reliable study to establish, immediately after the fractures, the possible presence of a post-traumatic ischemic necrosis. Angiography, as a reliable diagnostic tool, has to be carried out in the most selective way and needs the image subtraction technique. The authors report their preliminary results on the reliability of angiography in the femoral epiphyseal ischemic necrosis diagnosed by comparing the results of angiography with the wood light test carried out on the surgically removed femoral head. 18 refs.

  17. [Femoral artery pseudoaneurysms encountered in orthopedics and traumatology].

    Science.gov (United States)

    Raherinantenaina, F; Rajaonanahary, T M A; Rakoto Ratsimba, H N

    2015-12-01

    Most published articles regarding orthopedic- and trauma-related femoral artery pseudoaneurysms (FAPs) are case reports in English. Reported cases are often associated with a literature review but actually provide little robust data. We wanted to summarize the current knowledge on diagnostic and therapeutic features of these FAPs. A new case of superficial FAP is described followed by a review of the literature. A bibliographic search was performed online (PubMed, ScinceDirect) from 1964 to 2015 using the descriptors "traumatic femoral pseudoaneurysm, orthopedic surgery, osteochondroma". A total of 64 cases of FAPs was analyzed. There were 50 men with an average age of 40.72±26.45 years old. The most common clinical presentation was painful swelling (34%). Arteriography was the commonest radiological investigation used (63%). The main etiologies were orthopedic injuries (47%), surgery of the upper thigh (30%) and femoral osteochondromas (23%). Arterial injuries included superficial femoral (47%) and profunda femoris artery (50%). The treatment was open surgery (56%) or endovascular repair (36%). Deep femoral artery and its branches were embolized (47%) or ligated (38%). Endovascular stenting was performed in 30% of posttraumatic FAPs. All FAPs relating to osteochondromas were repaired surgically. Postoperative courses were uneventful in 95% of patients. Endovascular embolization is preferred in management of postsurgical FAPs which have usually involved the deep femoral artery. Endovascular stenting graft may be proposed for posttraumatic FAPs, for which the superficial femoral trunk is the most often involved vessel. Surgical repair should be performed when endovascular stenting graft is not feasible. Surgical repair is mandatory for all FAPs secondary to traumatic exostoses. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  18. Dielectric properties of agricultural materials and their applications

    CERN Document Server

    Nelson, Stuart

    2015-01-01

    Dielectric Properties of Agricultural Materials and Their Applications provides an understanding of the fundamental principles governing dielectric properties of materials, describes methods for measuring such properties, and discusses many applications explored for solving industry problems. The information in this reference stimulates new research for solving problems associated with production, handling, and processing of agricultural and food products. Anyone seeking a better understanding of dielectric properties of materials and application of radio-frequency and microwave electromagnetic energy for solution of problems in agriculture and related fields will find this an essential resource. Presents applications of dielectric properties for sensing moisture in grain and seed and the use of such properties in radio-frequency and microwave dielectric heating of agricultural materials Offers information for finding correlations between dielectric properties and quality attributes such as sweetness in melon...

  19. Marginal zone in femoral head avascular necrosis: scintigraphic characteristics and clinical prognostic value

    International Nuclear Information System (INIS)

    Milcinski, M.; Sedonja, I.; Dolinar, D.; Jevtic, V.

    2002-01-01

    Aim: Marginal zone, seen on magnetic resonance imaging (MRI) in femoral head avascular necrosis, consists of granulation tissue and sclerosis at the junction of necrotic and normal bone. Prognostic value of this finding is not clear. Aim of our study was to evaluate osteoblastic activity of marginal zone with bone scintigraphy and to assess prognostic importance of marginal zone for further evolution of femoral head necrosis. Material and methods: MRI was performed in 37 hips in 26 patients (17 m, 9 f, 20-64 y, mean 42,9 y) with Ficat 0-II avascular necrosis (SE T1W, STIR and SE T1W FAT.SAT after Gd DTPA in the coronal plane and GE FLASH in the sagittal plane). In 26 hips of 17 patients planar and pinhole scintigraphy with 99mTc-DPD was performed. Results: On MRI, marginal zone divided necrotic and normal bone in 26/37 (70,3%) hips, in 14/26 it was thin (2% of femoral head diameter or less), but in 12/26 it was wide (more than 2% of femoral head diameter). In 11/37 (29,7%) hips marginal zone was not seen. Pinhole scintigraphy was performed in 26 hips; in all 10/10 (100%) hips with wide marginal zone, seen on MRI, increased osteoblastic activity was detected, while only in 1/9 (11,1%) hips with thin marginal zone on MRI osteoblastic activity was increased. Patients were followed 1 to 5 years (mean 2,2 y). In hips without marginal zone no collapse of femoral head was seen until now, in 2/11 (18,2%) femoral heads MRI and clinical regression was observed. Ten of 12 lesions with wide marginal zone (83,3 %) collapsed 0,25 to 2,5 (mean 1) years after onset of pain. Two of 12 lesions with wide marginal zone (16,7%) have not collapsed until now. From lesions with thin marginal zone, 4/14 (28,6 %) collapsed 0,7 to 3 (mean 1,9) years after onset of pain, 10/14 (71,4%) did not collapse until now. Conclusion: Increased osteoblastic activity in wide marginal zone between necrotic and vital bone in hip avascular necrosis is bad prognostic factor for femoral head collapse

  20. Material properties in complement activation

    DEFF Research Database (Denmark)

    Moghimi, S. Moein; Andersen, Alina Joukainen; Ahmadvand, Davoud

    2011-01-01

    activation differently and through different sensing molecules and initiation pathways. The importance of material properties in triggering complement is considered and mechanistic aspects discussed. Mechanistic understanding of complement events could provide rational approaches for improved material design...

  1. [Midterm follow-up results on Asian femoral intramedullary nail for the treatment of segmental and comminuted femoral fractures].

    Science.gov (United States)

    Li, Lang; Gao, Feng; Huang, Qi; Li, Qiang; Xie, Lin; Zhang, Bin

    2016-06-01

    To investigate midterm follow-up results on Asian femoral intramedullary nail in treating segmental and comminuted femoral fractures. Between June 2011 and October 2012,16 patients with segmental and comminuted femoral fractures were treated with minimally invasive reset and Asian femoral intramedullary nail under extension table. Among them, there were 10 males and 6 females aged from 21 to 49 years old with an average of 34.5 years old; the time from injury to operation ranged from 3 to 24 d with an average of 9.1 d. There were 6 cases were type C1,2 cases were type C2 and 8 cases were type C3 according to AO classification. X-ray of femoral segment at 3,6 and 12 months after operation were applied for evaluating fracture healing. Harris score of hip joint and HSS score of knee joint were used to evaluate postoperative function. All patients were followed up from 24 to 36 months with an average of 28.4 months. Operative time was from 88 to 112 min with an average of 90.7 min; blood loss ranged from 150 to 200 ml with an average of 188.75 ml; the time of fracture healing was from 5 to 9 months with an average of 5.4 months. All incision were healed at stage I. No loosening, breakage of internal fixation and displacement of fracture were occurred. There were no significant differences in Harris score of hip joint at 3, 6 and 12 months after operation (F = 0.07, P = 0.893 > 0.05), 10 cases obtained excellent results, 5 good and 1 moderate. There was no obvious meaning in HSS score of knee joint (F = 0.08,P = 0.876 > 0.05), 9 cases obtained excellent results, 6 good and 1 poor. Asian femoral intramedullary nail could treat segmental and comminuted femoral fractures by using variety of less invasive ways,which has advantages of less trauma, quick recovery of function and satisfied midterm following-up results. But long term following-up effects remains to be seen.

  2. Optical properties of low-dimensional materials

    CERN Document Server

    Ogawa, T

    1998-01-01

    This book surveys recent theoretical and experimental studies of optical properties of low-dimensional materials. As an extended version of Optical Properties of Low-Dimensional Materials (Volume 1, published in 1995 by World Scientific), Volume 2 covers a wide range of interesting low-dimensional materials including both inorganic and organic systems, such as disordered polymers, deformable molecular crystals, dilute magnetic semiconductors, SiGe/Si short-period superlattices, GaAs quantum wires, semiconductor microcavities, and photonic crystals. There are excellent review articles by promis

  3. Data analytics and parallel-coordinate materials property charts

    Science.gov (United States)

    Rickman, Jeffrey M.

    2018-01-01

    It is often advantageous to display material properties relationships in the form of charts that highlight important correlations and thereby enhance our understanding of materials behavior and facilitate materials selection. Unfortunately, in many cases, these correlations are highly multidimensional in nature, and one typically employs low-dimensional cross-sections of the property space to convey some aspects of these relationships. To overcome some of these difficulties, in this work we employ methods of data analytics in conjunction with a visualization strategy, known as parallel coordinates, to represent better multidimensional materials data and to extract useful relationships among properties. We illustrate the utility of this approach by the construction and systematic analysis of multidimensional materials properties charts for metallic and ceramic systems. These charts simplify the description of high-dimensional geometry, enable dimensional reduction and the identification of significant property correlations and underline distinctions among different materials classes.

  4. Computerized tomography in evaluation of decreased acetabular and femoral anteversion

    International Nuclear Information System (INIS)

    Toennis, D.; Skamel, H.J.

    2003-01-01

    Computerized tomography has received a new importance. It has been shown that decreased anteversion of femur and acetabulum, when both have decreased angles, are causing pain and osteoarthritis of the hip joint. Operative treatment should be performed before osteoarthritis develops. Exact measurements therefore are necessary. The investigation should be performed in prone position to have the pelvis lying in a defined and normal position. Femoral torsion is measured between the transverse axis of the knee and the femoral neck. The transverse axis for measurement of the femoral anteversion is defined by a rectangular line to the sagittal plane. For evaluation of the femoral anteversion in total the angle of the condyles has to be added to the femoral neck angle when the knee is found in internal rotation. Acetabular anteversion should be measured at the level where the femoral head is still in full contact and congruence with the anterior margin of the acetabulum. (orig.) [de

  5. Microstructure and properties of ceramic materials

    International Nuclear Information System (INIS)

    Yen Tungsheng

    1984-01-01

    Ceramics materials study is an important field in modern materials science. Each side presented 19 papers most of which were recent investigations giving rather extensive coverage of microstructure and properties of new materials. (Auth.)

  6. Estimated carotid-femoral pulse wave velocity has similar predictive value as measured carotid-femoral pulse wave velocity

    DEFF Research Database (Denmark)

    Greve, Sara V; Blicher, Marie K; Kruger, Ruan

    2016-01-01

    BACKGROUND: Carotid-femoral pulse wave velocity (cfPWV) adds significantly to traditional cardiovascular risk prediction, but is not widely available. Therefore, it would be helpful if cfPWV could be replaced by an estimated carotid-femoral pulse wave velocity (ePWV) using age and mean blood pres...... that these traditional risk scores have underestimated the complicated impact of age and blood pressure on arterial stiffness and cardiovascular risk....

  7. Semiconductor materials and their properties

    NARCIS (Netherlands)

    Reinders, Angelina H.M.E.; Verlinden, Pierre; van Sark, Wilfried; Freundlich, Alexandre; Reinders, Angele; Verlinden, Pierre; van Sark, Wilfried; Freundlich, Alexandre

    2017-01-01

    Semiconductor materials are the basic materials which are used in photovoltaic (PV) devices. This chapter introduces solid-state physics and semiconductor properties that are relevant to photovoltaics without spending too much time on unnecessary information. Usually atoms in the group of

  8. Mechanical Properties of Composite Materials

    Directory of Open Access Journals (Sweden)

    Mitsuhiro Okayasu

    2014-10-01

    Full Text Available An examination has been made of the mechanical and failure properties of several composite materials, such as a short and a long carbon fiber reinforced plastic (short- and long-CFRP and metal based composite material. The short CFRP materials were used for a recycled CFRP which fabricated by the following process: the CFRP, consisting of epoxy resin with carbon fiber, is injected to a rectangular plate cavity after mixing with acrylonitrile butadiene styrene resin with different weight fractions of CFRP. The fatigue and ultimate tensile strength (UTS increased with increasing CFRP content. These correlations, however, break down, especially for tensile strength, as the CFPR content becomes more than 70%. Influence of sample temperature on the bending strength of the long-CFRP was investigated, and it appears that the strength slightly degreases with increasing the temperature, due to the weakness in the matrix. Broken fiber and pull-out or debonding between the fiber and matrix were related to the main failure of the short- and long-CFRP samples. Mechanical properties of metal based composite materials have been also investigated, where fiber-like high hardness CuAl2 structure is formed in aluminum matrix. Excellent mechanical properties were obtained in this alloy, e.g., the higher strength and the higher ductility, compared tothe same alloy without the fiber-like structure. There are strong anisotropic effects on the mechanical properties due to the fiber-like metal composite in a soft Al based matrix.

  9. A cementless, proximally fixed anatomic femoral stem induces high micromotion with nontraumatic femoral avascular necrosis: A finite element study

    Directory of Open Access Journals (Sweden)

    Wen-Chuan Chen

    2014-07-01

    Full Text Available Decrease in bone mineral density of metaphysis in patients with nontraumatic avascular necrosis of the femoral head (AVN is considered the main factor leading to aseptic loosening of the femoral component. Researchers have hypothesized that a cementless, anatomic stem fixed proximally to the metaphysis has a higher risk for aseptic loosening than a straight stem that is fixed at the diaphysis in patients with nontraumatic AVN. The purpose of the current study was to evaluate the effects of cancellous bone stiffness at the metaphysis and stem geometry on the micromotion of the femoral stem relative to the femur. The VerSys (straight and ABG (anatomic femoral stems were enrolled in this finite element study to determine the performance of prosthetic micromotion. The simulated load to the hip joint during heel strike was assigned. Results showed that the VerSys model represented better resistance in micromotion between the bone/stem interface than the ABG model in either normal or poor cancellous bone stiffness at the metaphysis. The bone quality at the metaphysis of patients with nontraumatic AVN should be considered prior to selecting a femoral stem. In consideration of initial stability, acementless, straight stem that fits the isthmus is more favourable than an anatomic stem that is fixed to the proximal area of the canal.

  10. Femoral Condyle Fracture during Anterior Cruciate Ligament Reconstruction

    Directory of Open Access Journals (Sweden)

    Selahattin Ozyurek

    2015-07-01

    Full Text Available Dear Editor,We have greatly enjoyed reading the case report entitled “‘Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature in the issue of Arch Bone Jt Surg. 2015;3(2 with great interest. We would like to commend the authors for their detailed and valuable work. Although various case reports have described postoperative distal femur fracture at a range of time intervals (1,2 intraoperative intra-articular distal femur fracture is a unique entity.However, we believe that some important additional observations seem necessary to be contributed through this study. In this article, the authors stated that, to the best of their knowledge, there is no other case report in the literature introducing a femoral condyle fracture during arthroscopic ACL reconstruction or revision reconstruction. Nevertheless, we would like to call the attention of the readers to the fact that that the literature contains one additional case report re‌porting on intraoperative distal femoral coronal plane (Hoffa fracture during primary ACL reconstruction (2. Werner BC and Miller MD presented of case report of an intraoperative distal femoral coronal plane (Hoffa fracture that occurred during independent femoral tunnel drilling and dilation in a primary ACL reconstruction. As in the their case, this type of fracture can occur with appropriately placed femoral tunnels, but the risk can increase with larger graft diameters in patients with smaller lateral femoral condyles The patient was treated with open reduction and internal fixation, without compromise of graft stability and with good recovery of function. We believe that tailoring graft size to the size of the patient is important to prevent similar adverse events.

  11. Computed tomographic evaluation of the proximal femur: A predictive classification in displaced femoral neck fracture management

    Directory of Open Access Journals (Sweden)

    Narender Kumar Magu

    2014-01-01

    Full Text Available Background: Femoral neck fracture is truly an enigma due to the high incidence of avascular necrosis and nonunion. Different methods have been described to determine the size of the femoral head fragment, as a small head has been said to be associated with poor outcome and nonunion due to inadequate implant purchase in the proximal fragment. These methods were two dimensional and were affected by radiography techniques, therefore did not determine true head size. Computed tomography (CT is an important option to measure true head size as images can be obtained in three dimensions. Henceforth, we subjected patients to CT scan of hip in cases with displaced fracture neck of femur. The study aims to define the term "small head or inadequate size femoral head" objectively for its prognostic significance. Materials and Methods: 70 cases of displaced femoral neck fractures underwent CT scan preoperatively for proximal femoral geometric measurements of both hips. Dual energy X-ray absorptiometry scan was done in all cases. Patients were treated with either intertrochanteric osteotomy or lag screw osteosynthesis based on the size of the head fragment on plain radiographs. Results: The average femoral head fragment volume was 57 cu cm (range 28.3-84.91 cu cm; standard deviation 14 cu cm. Proximal fragment volume of >43 cu cm was termed adequate size (type I and of ≤43 cu cm as small femoral head (type II. Fractures which united (n = 54 had a relatively large average head size (59 cu cm when compared to fractures that did not (n = 16, which had a small average head size (49 cu cm and this difference was statistically significant. In type I fractures union rate was comparable in both osteotomy and lag screw groups (P > 0.05. Lag screw fixation failed invariably, while osteotomy showed good results in type II fractures (P < 0.05. Conclusion: Computed tomography scan of the proximal femur is advisable for measuring true size of head fragment. An objective

  12. Nuclear materials thermo-physical property database and property analysis using the database

    International Nuclear Information System (INIS)

    Jeong, Yeong Seok

    2002-02-01

    It is necessary that thermo-physical properties and understand of nuclear materials for evaluation and analysis to steady and accident states of commercial and research reactor. In this study, development of nuclear materials thermo-properties database and home page. In application of this database, it is analyzed of thermal conductivity, heat capacity, enthalpy, and linear thermal expansion of fuel and cladding material and compared thermo-properties model in nuclear fuel performance evaluation codes with experimental data in database. Results of compare thermo-property model of UO 2 fuel and cladding major performance evaluation code, both are similar

  13. Femoral neck fractures complicating gaucher disease in children

    International Nuclear Information System (INIS)

    Goldman, A.B.; Jacobs, B.

    1984-01-01

    In normal children, fractures of the femoral neck are uncommon and accompany severe trauma and multiple injuries elsewhere in the skeleton. In children with Gaucher disease, a rare hereditary disorder of lipid metabolism, midcervical or basicervical fractures can occur with minor or no trauma and without other injury to the skeleton. Three children with Gaucher disease who developed pathologic fractures of the femoral neck are described. In all three, the fractures occurred between five and nine years of age, and the fracture lines passed through areas of abnormal bone characterized by poorly defined patches of increased and decreased density and cortical thinning along the medial femoral necks. In the affected hips, there was no evidence of avascular necrosis of the femoral heads at the time of injury. One child's fracture was preceeded by multiple bone 'crisis' localized to the proximal femora. (orig.)

  14. Femoral neck fractures complicating gaucher disease in children

    Energy Technology Data Exchange (ETDEWEB)

    Goldman, A B; Jacobs, B

    1984-09-01

    In normal children, fractures of the femoral neck are uncommon and accompany severe trauma and multiple injuries elsewhere in the skeleton. In children with Gaucher disease, a rare hereditary disorder of lipid metabolism, midcervical or basicervical fractures can occur with minor or no trauma and without other injury to the skeleton. Three children with Gaucher disease who developed pathologic fractures of the femoral neck are described. In all three, the fractures occurred between five and nine years of age, and the fracture lines passed through areas of abnormal bone characterized by poorly defined patches of increased and decreased density and cortical thinning along the medial femoral necks. In the affected hips, there was no evidence of avascular necrosis of the femoral heads at the time of injury. One child's fracture was preceeded by multiple bone 'crisis' localized to the proximal femora.

  15. Fixation strength of a polyetheretherketone femoral component in total knee arthroplasty.

    Science.gov (United States)

    de Ruiter, Lennert; Janssen, Dennis; Briscoe, Adam; Verdonschot, Nico

    2017-11-01

    Introducing polyetheretherketone (PEEK) polymer as a material for femoral components in total knee arthroplasty (TKA) could potentially lead to a reduction of the cemented fixation strength. A PEEK implant is more likely to deform under high loads, rendering geometrical locking features less effective. Fixation strength may be enhanced by adding more undercuts or specific surface treatments. The aim of this study is to measure the initial fixation strength and investigate the associated failure patterns of three different iterations of PEEK-OPTIMA ® implants compared with a Cobalt-Chromium (CoCr) component. Femoral components were cemented onto trabecular bone analogue foam blocks and preconditioned with 86,400 cycles of compressive loading (2600 N-260 N at 1 Hz). They were then extracted while the force was measured and the initial failure mechanism was recorded. Four groups were compared: CoCr, regular PEEK, PEEK with an enhanced cement-bonding surface and the latter with additional surface primer. The mean pull-off forces for the four groups were 3814 N, 688 N, 2525 N and 2552 N, respectively. The initial failure patterns for groups 1, 3 and 4 were the same; posterior condylar foam fracture and cement-bone debonding. Implants from group 2 failed at the cement-implant interface. This study has shown that a PEEK-OPTIMA ® femoral TKA component with enhanced macro- and microtexture is able to replicate the main failure mechanism of a conventional CoCr femoral implant. The fixation strength is lower than for a CoCr implant, but substantially higher than loads occurring under in-vivo conditions. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. Transfracture abduction osteotomy: A solution for nonunion of femoral neck fractures

    Directory of Open Access Journals (Sweden)

    Jairamchander Pingle

    2014-01-01

    femur with or without bone graft, valgus osteotomy or hip arthroplasty. We conducted a retrospective analysis of cases of nonunion of femoral neck fracture treated by transfracture abduction osteotomy (TFAO. Materials and Methods: Over a period of 35 years (1974-2008, 30 patients with nonunion of femoral neck fractures were treated with TFAO over a period of 35 years (1974-2008, All patients were less than 50 years of age. Absence of clinical and radiological signs of union after four months was considered as nonunion. Patients more than 50 years of age were excluded from the study. Union was assessed at 6 months radiologically. Limb length was measured at six months. The mean duration of femoral neck fracture was 19 months (range 4 months 10 years. Results were analyzed in terms of radiological union at six months. Average followup was five years and six months. Results: Consistent union was noted at the followup after six months in 29 cases. One case was lost to followup after five and one-half months postoperatively. However, the fracture had united in this case at the last followup. Average shortening of the limb at six months was 1.9 cm. Average neck shaft angle was 127° (range 120-145°. Five cases went into AVN but were asymptomatic. Two cases required reoperation due to back out of Moore′s pins. These were reopened and cancellous screws were inserted in the same tracks. Conclusions: Consistent union of nonunion femoral neck fracture was noted at the followup after six months in 29 cases. The major drawback of the procedure is immobilization of the patient in the hip spica for eight weeks.

  17. frequency of ipsilateral femoral neck fractures in patients

    African Journals Online (AJOL)

    Background: Ipsilateral associated femoral neck and shaft fractures are reported to occur in 2.5-6% of all femoral shaft ... nailing of the shaft fracture, which makes treatment of the neck ... chest, spine), while the other had maxillofacial injuries.

  18. Proximal femoral fractures

    DEFF Research Database (Denmark)

    Palm, Henrik; Teixidor, Jordi

    2015-01-01

    searched the homepages of the national heath authorities and national orthopedic societies in West Europe and found 11 national or regional (in case of no national) guidelines including any type of proximal femoral fracture surgery. RESULTS: Pathway consensus is outspread (internal fixation for un...

  19. Porous Materials - Structure and Properties

    DEFF Research Database (Denmark)

    Nielsen, Anders

    1997-01-01

    The paper presents some viewpoints on the description of the pore structure and the modelling of the properties of the porous building materials. Two examples are given , where it has been possible to connect the pore structure to the properties: Shrinkage of autoclaved aerated concrete...

  20. Bioactive glasses materials, properties and applications

    CERN Document Server

    Ylänen, Heimo

    2011-01-01

    Due to their biocompatibility and bioactivity, bioactive glasses are used as highly effective implant materials throughout the human body to replace or repair damaged tissue. As a result, they have been in continuous use since shortly after their invention in the late 1960s and are the subject of extensive research worldwide.Bioactive glasses provides readers with a detailed review of the current status of this unique material, its properties, technologies and applications. Chapters in part one deal with the materials and mechanical properties of bioactive glass, examining topics such

  1. Localized cortical thickening of the femoral diaphysis captured on an X-ray before alendronate therapy in two cases of atypical femoral fracture

    Energy Technology Data Exchange (ETDEWEB)

    Iizuka, Yoichi [Gunma University Graduate School of Medicine, Department of Orthopedic Surgery, Maebashi, Gunma (Japan); Shibukawa General Hospital, Department of Orthopedic Surgery, Shibukawa, Gunma (Japan); Takechi, Rumi [Gunma University Graduate School of Medicine, Department of Orthopedic Surgery, Maebashi, Gunma (Japan); Gunma Cardiovascular Center, Department of Orthopaedic Surgery, Maebashi, Gunma (Japan); Iizuka, Haku; Takagishi, Kenji [Gunma University Graduate School of Medicine, Department of Orthopedic Surgery, Maebashi, Gunma (Japan); Omodaka, Takuya [Gunma University Graduate School of Medicine, Department of Orthopedic Surgery, Maebashi, Gunma (Japan); Gunma Central Hospital, Department of Orthopedic Surgery, Maebashi, Gunma (Japan)

    2016-10-15

    We herein report two cases of atypical femoral fracture (AFF). X-ray examinations at the first visit of these two female patients showed a complete fracture of the femoral diaphysis diagnosed as an atypical femoral fracture (AFF). X-rays of these two cases also showed localized cortical thickening of the femoral diaphysis. Both patients had been taking alendronate for more than 3 years because of postmenopausal osteoporosis. We assumed that both of the fractures were associated with the long-term use of alendronate. However, we retrospectively identified localized cortical thickening of the femoral diaphysis on an X-ray taken before the alendronate therapy in both of these cases. Therefore, we suspected a pathogenesis of AFFs in which preexisting stress or an insufficient fracture unrelated to bisphosphonate (BP) therapy and subsequent suppression of bone turnover due to BP administration led to the occurrence of an AFF. The patient underwent surgery using intramedullary nails in both of these cases, followed by the administration of teriparatide, and they were able to walk without any support at the final follow-up examination. (orig.)

  2. MR findings in cases of suspected impacted fracture of the femoral neck

    International Nuclear Information System (INIS)

    Stiris, M.G.; Lilleaas, F.G.

    1997-01-01

    Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had an impacted femoral neck fracture and the other a nondisplaced intertrochanteric fracture. There was 1 patient who had sustained a nondisplaced acetabular fracture with increased joint fluid and muscle contusions. Three patients had muscle contusions only. Two patients had bone marrow contusions only, while 2 others with advanced coxarthrosis had increased joint fluid only. Three patients showed normal findings. Our findings led to emergency surgery in 13 cases, and conservative measures directed to the specific MR findings in 14 patients. Conclusion: MR imaging should be the first modality of choice in examining patients with a clinically suspected impacted fracture of the femoral neck where conventional films show negative or equivocal findings. (orig.)

  3. MR findings in cases of suspected impacted fracture of the femoral neck

    Energy Technology Data Exchange (ETDEWEB)

    Stiris, M.G.; Lilleaas, F.G. [Aker Hospital, Oslo (Norway). Dept. of Diagnostic Radiology

    1997-09-01

    Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had an impacted femoral neck fracture and the other a nondisplaced intertrochanteric fracture. There was 1 patient who had sustained a nondisplaced acetabular fracture with increased joint fluid and muscle contusions. Three patients had muscle contusions only. Two patients had bone marrow contusions only, while 2 others with advanced coxarthrosis had increased joint fluid only. Three patients showed normal findings. Our findings led to emergency surgery in 13 cases, and conservative measures directed to the specific MR findings in 14 patients. Conclusion: MR imaging should be the first modality of choice in examining patients with a clinically suspected impacted fracture of the femoral neck where conventional films show negative or equivocal findings. (orig.).

  4. Iodixanol in femoral arteriography

    International Nuclear Information System (INIS)

    Thorstensen, Oe.; Albrechtsson, U.; Calissendorff, B.; Larusdottir, H.; Norgren, L.; Tengvar, M.; Bolstad, B.; Aspelin, P.

    1994-01-01

    Two contrast media, iodixanol (Visipaque, Nycomed) 270 mg I/ml and iohexol (Omnipaque, Nycomed) 300 mg I/ml, were compared in femoral arteriography, in 147 patients. Both contrast media were diagnostically effective for use in femoral arteriography, without any significant difference. Pain was reported in connection with injection of iohexol by 36% of the patients, after injection of iodixanol none reported pain. Seventy-two percent of the patients in the iodixanol group reported a sensation of warmth in connection with contrast injection versus 90% in the iohexol group. The average intensity of the warmth was greater with iohexol than with iodixanol. Fourteen percent of patients in the iodixanol group and 1% in the iohexol group reported one or more subjective adverse events. (orig.)

  5. Femoral Neck Shaft Angle in Men with Fragility Fractures

    Directory of Open Access Journals (Sweden)

    S. P. Tuck

    2011-01-01

    Full Text Available Introduction. Femoral neck shaft angle (NSA has been reported to be an independent predictor of hip fracture risk in men. We aimed to assess the role of NSA in UK men. Methods. The NSA was measured manually from the DXA scan printout in men with hip (62, 31 femoral neck and 31 trochanteric, symptomatic vertebral (91, and distal forearm (67 fractures and 389 age-matched control subjects. Age, height, weight, and BMD (g/cm2: lumbar spine, femoral neck, and total femur measurements were performed. Results. There was no significant difference in mean NSA between men with femoral neck and trochanteric hip fractures, so all further analyses of hip fractures utilised the combined data. There was no difference in NSA between those with hip fractures and those without (either using the combined data or analysing trochanteric and femoral neck shaft fractures separately, nor between fracture subjects as a whole and controls. Mean NSA was smaller in those with vertebral fractures (129.2° versus 131°: P=0.001, but larger in those with distal forearm fractures (129.8° versus 128.5°: P=0.01. Conclusions. The conflicting results suggest that femoral NSA is not an important determinant of hip fracture risk in UK men.

  6. Logistic regression analysis of factors associated with avascular necrosis of the femoral head following femoral neck fractures in middle-aged and elderly patients.

    Science.gov (United States)

    Ai, Zi-Sheng; Gao, You-Shui; Sun, Yuan; Liu, Yue; Zhang, Chang-Qing; Jiang, Cheng-Hua

    2013-03-01

    Risk factors for femoral neck fracture-induced avascular necrosis of the femoral head have not been elucidated clearly in middle-aged and elderly patients. Moreover, the high incidence of screw removal in China and its effect on the fate of the involved femoral head require statistical methods to reflect their intrinsic relationship. Ninety-nine patients older than 45 years with femoral neck fracture were treated by internal fixation between May 1999 and April 2004. Descriptive analysis, interaction analysis between associated factors, single factor logistic regression, multivariate logistic regression, and detailed interaction analysis were employed to explore potential relationships among associated factors. Avascular necrosis of the femoral head was found in 15 cases (15.2 %). Age × the status of implants (removal vs. maintenance) and gender × the timing of reduction were interactive according to two-factor interactive analysis. Age, the displacement of fractures, the quality of reduction, and the status of implants were found to be significant factors in single factor logistic regression analysis. Age, age × the status of implants, and the quality of reduction were found to be significant factors in multivariate logistic regression analysis. In fine interaction analysis after multivariate logistic regression analysis, implant removal was the most important risk factor for avascular necrosis in 56-to-85-year-old patients, with a risk ratio of 26.00 (95 % CI = 3.076-219.747). The middle-aged and elderly have less incidence of avascular necrosis of the femoral head following femoral neck fractures treated by cannulated screws. The removal of cannulated screws can induce a significantly high incidence of avascular necrosis of the femoral head in elderly patients, while a high-quality reduction is helpful to reduce avascular necrosis.

  7. Flexible intramedullary nailing for femoral diaphyseal fractures in children

    Directory of Open Access Journals (Sweden)

    Rojan Tamrakar

    2017-12-01

    Full Text Available Background & Objectives: Although various treatment options are available for the treatment of femoral diaphyesal fractures in children, the titanium flexible nailing has gained popularity because it is safe, easy procedure with rapid recovery and high success rate. The aim of this study was to evaluate the outcome of titanium elastic nails in treating paediatric femoral diaphyesal fractures at Patan Hospital.Materials & Methods: There were 35 cases which were all fixed with titanium flexible intramedullary nail under image intensifier at the Patan hospital from January 2013 and December 2015. Patients were evaluated in follow-ups to observe the alignment of fracture, infection, delayed union, nonunion, limb length discrepancy, implant failure, range of movement of hip and knee joints, and time to unite the fracture. The final results were evaluated using criteria of titanium elastic nail (TEN outcome score described by Flynn et al.Results: The mean age of the patients was 8.51 years. Among 35 patients (22 boys and 13 girls, there were 19 mid-shaft fractures, nine proximal third fractures and seven distal third fractures. Fracture patterns were transverse (22, oblique (10, spiral (2, and comminuted (2. The mean time for fracture union was 8.17 weeks radiologically whereas 9.83 weeks clinically. According to TEN outcome score, excellent and good results were in 28 cases (80% and seven cases (20% respectively.Conclusion: Flexible titanium nailing is a safe and satisfactory treatment for diaphyseal femoral fractures in children, because it provides rapid recovery, short rehabilitation and immobilization as well as very high union rate with few complications.

  8. Combined Radial and Femoral Access Strategy and Radial-Femoral Rendezvous in Patients With Long and Complex Iliac Occlusions.

    Science.gov (United States)

    Hanna, Elias B; Mogabgab, Owen N; Baydoun, Hassan

    2018-01-01

    We present cases of complex, calcified iliac occlusive disease revascularized via a combined radial-femoral access strategy. Through a 6-French, 125-cm transradial guiding catheter, antegrade guidewires and catheters are advanced into the iliac occlusion, while retrograde devices are advanced transfemorally. The transradial and transfemoral channels communicate, allowing the devices to cross the occlusion into the true lumen (radial-femoral antegrade-retrograde rendezvous).

  9. 'Femoral head necrosis' in metabolic and hormonal osteopathies

    International Nuclear Information System (INIS)

    Heuck, F.H.W.; Treugut, H.

    1984-01-01

    The pathogenesis of bone necrosis is discussed with special attention and with respect to metabolic, hormonal, and vascular factors. The influence of statics and dynamics of the hip joint bones for the development of aseptic necrosis are discussed. 45 patients with ''idiopathic femoral head necroses'' were observed, including 6 cases of renal osteopathy following renal transplantation and immune suppression therapy, 14 cases of long term corticoid therapy, and 11 cases of liver diseases of different genesis. The femoral head necrosis understood as complication of an osteopathy. In our patients there were 31 males and 14 females - which means higher involvement of males. Plain radiological findings and CT-findings of changes of the femoral heat structure in different stages of the disease are described. Early diagnosis of metabolic and hormonal osteopathies is demanded for a joint keeping therapy of the beginning femoral head necrosis. (orig.) [de

  10. Femoral neck fractures complicating gaucher disease in children

    Energy Technology Data Exchange (ETDEWEB)

    Goldman, A.B.; Jacobs, B.

    1984-09-01

    In normal children, fractures of the femoral neck are uncommon and accompany severe trauma and multiple injuries elsewhere in the skeleton. In children with Gaucher disease, a rare hereditary disorder of lipid metabolism, midcervical or basicervical fractures can occur with minor or no trauma and without other injury to the skeleton. Three children with Gaucher disease who developed pathologic fractures of the femoral neck are described. In all three, the fractures occurred between five and nine years of age, and the fracture lines passed through areas of abnormal bone characterized by poorly defined patches of increased and decreased density and cortical thinning along the medial femoral necks. In the affected hips, there was no evidence of avascular necrosis of the femoral heads at the time of injury. One child's fracture was preceeded by multiple bone 'crisis' localized to the proximal femora.

  11. Dynamic mechanical properties of buffer material

    International Nuclear Information System (INIS)

    Takaji, Kazuhiko; Taniguchi, Wataru

    1999-11-01

    The buffer material is expected to maintain its low water permeability, self-sealing properties, radionuclides adsorption and retardation properties, thermal conductivity, chemical buffering properties, overpack supporting properties, stress buffering properties, etc. over a long period of time. Natural clay is mentioned as a material that can relatively satisfy above. Among the kinds of natural clay, bentonite when compacted is superior because (i) it has exceptionally low water permeability and properties to control the movement of water in buffer, (ii) it fills void spaces in the buffer and fractures in the host rock as it swells upon water uptake, (iii) it has the ability to exchange cations and to adsorb cationic radioelements. In order to confirm these functions for the purpose of safety assessment, it is necessary to evaluate buffer properties through laboratory tests and engineering-scale tests, and to make assessments based on the ranges in the data obtained. This report describes the procedures, test conditions, results and examinations on the buffer material of dynamic triaxial tests, measurement of elastic wave velocity and liquefaction tests that aim at getting hold of dynamic mechanical properties. We can get hold of dependency on the shearing strain of the shearing modulus and hysteresis damping constant, the application for the mechanical model etc. by dynamic triaxial tests, the acceptability of maximum shearing modulus obtained from dynamic triaxial tests etc. by measurement of elastic wave velocity and dynamic strength caused by cyclic stress etc. by liquefaction tests. (author)

  12. Anatomic landmarks of fluoroscopy guided puncture of the pulseless femoral artery

    International Nuclear Information System (INIS)

    Jeon, Min Hee; Han, Gi Seok; Kim, Sung Jin; Park, Kil Sun; Cha, Sang Hoon; Bae, Il Hun; Lee, Seung Young

    2006-01-01

    We wanted to improve puncturing the pulseless femoral artery by evaluating the anatomic landmarks that suggest the course of the femoral artery on fluoroscopy. We analyzed 37 hemipelvis spot images that were centered on the arterial sheath after puncture of the femoral artery. The inguinal angles were measured between the inguinal line connecting the anterior superior iliac spine and the symphysis pubis, and the line of the arterial sheath. Inguinal ligament ratios were measured as the distance from the symphysis pubis to the arterial sheath to the length of the inguinal ligament on the inguinal line. The femoral head ratios were measured as the distance from the medial margin of the femur head to the arterial sheath to the transverse length of the femur head. The mean inguinal angle was 66.5 and the mean inguinal ligament ratio was 0.42 (± 0.03). The mean femoral head ratio was 0.08 (± 0.18). In comparing the men and women, there was no significant difference in the inguinal angle and the femoral head ratio, but the inguinal distance ratio was larger in women (men: 0.41 ± 0.033, women: 0.44 ± 0.031, ρ < 0.05). The femoral artery generally courses just lateral to the medial margin of the femur head (femoral head ratio: 0.08) and the medial 40% of the inguinal ligament (inguinal ligament ratio: 0.42). So, consideration of these relations may be helpful for puncturing the pulseless femoral artery

  13. MRI for early diagnosis of avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Kokubo, Takashi; Takatori, Yoshio; Kamogawa, Morihide; Ninomiya, Setsuo; Yoshikawa, Kohki; Itai, Yuji; Iio, Masahiro; Mitamura, Tadayuki

    1988-01-01

    Magnetic resonance imaging (MRI) was performed in forty patients on long-term oral steroid therapy for early detection of avascular necrosis (AN) of the femoral head. In 13 patients, AN was diagnosed in the unilateral femoral head from abnormal plain radiographs while the contralateral femoral head was normal radiographically. In the other 27 patients, radiographs were normal. A total of 67 femoral heads with normal radiographs is studied in this paper. In 36 of 67 femoral heads (54 %), MRI demonstrated abnormal low intensity area. The abnormal findings on MRI were divided into five patterns: whole type (type A), peripheral type (type B), ring or band type (type C), small change type (type D) and distal type (type E). Type A, B, C, D and E were found in 2, 11, 5, 16 and 2 femoral heads, respectively. In cases to be followed up over 6 months, AN was manifested radiographically in 4 femoral heads of 5 in type C and in one of 14 in type D. Meanwhile, in 6 of 41 femoral heads examined (15 %), bone scintigrams was abnormal. Followed-up study over 6 months revealed that AN was manifested radiographically in one femoral head of 6 with abnormal scintigram. However, in 4 of 30 with normal scintigram, AN was manifested subsequently. MRI was a better diagnostic modality for early AN. Ring or band-like low intensity (type C) on MRI was considered to be characteristic pattern of early AN. (author)

  14. MRI for early diagnosis of avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Kokubo, Takashi; Takatori, Yoshio; Kamogawa, Morihide; Ninomiya, Setsuo; Yoshikawa, Kohki; Itai, Yuji; Iio, Masahiro; Mitamura, Tadayuki

    1988-09-01

    Magnetic resonance imaging (MRI) was performed in forty patients on long-term oral steroid therapy for early detection of avascular necrosis (AN) of the femoral head. In 13 patients, AN was diagnosed in the unilateral femoral head from abnormal plain radiographs while the contralateral femoral head was normal radiographically. In the other 27 patients, radiographs were normal. A total of 67 femoral heads with normal radiographs is studied in this paper. In 36 of 67 femoral heads (54 %), MRI demonstrated abnormal low intensity area. The abnormal findings on MRI were divided into five patterns: whole type (type A), peripheral type (type B), ring or band type (type C), small change type (type D) and distal type (type E). Type A, B, C, D and E were found in 2, 11, 5, 16 and 2 femoral heads, respectively. In cases to be followed up over 6 months, AN was manifested radiographically in 4 femoral heads of 5 in type C and in one of 14 in type D. Meanwhile, in 6 of 41 femoral heads examined (15 %), bone scintigrams was abnormal. Followed-up study over 6 months revealed that AN was manifested radiographically in one femoral head of 6 with abnormal scintigram. However, in 4 of 30 with normal scintigram, AN was manifested subsequently. MRI was a better diagnostic modality for early AN. Ring or band-like low intensity (type C) on MRI was considered to be characteristic pattern of early AN.

  15. Material properties characterization - concrete

    International Nuclear Information System (INIS)

    England, G.L.; MacLeod, J.S.

    1978-01-01

    A review is presented of the six contributions in the SMiRT 4 conference to Session H5 on structural analysis of prestressed concrete reactor pressure vessels. These relate to short term stress-strain aspects of concrete loaded beyond the linear range in uniaxial and biaxial stress fields, to some time and temperature dependent properties of concrete at working stress levels, and to a programme of strain-gauge testing for the assessment of concrete properties. From the information discussed, it is clear that there are difficulties in determining material properties for concrete, and these are summarised. (UK)

  16. Properties of auxiliary filtering materials

    Energy Technology Data Exchange (ETDEWEB)

    Rudenko, L.I.; Sklyar, V.T.

    1981-01-01

    The authors have studied the physicochemical and filtering properties of the perlites FP-1 and FP-2, kieselguhr, diatomite, asbestos, wood pulp, and the diatomite powders Spidplace and Saperaid. They propose a classification for filtering materials according to their properties when mechanical impurities are being removed from the additives.

  17. Fully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty.

    Science.gov (United States)

    Arabnejad, Sajad; Johnston, Burnett; Tanzer, Michael; Pasini, Damiano

    2017-08-01

    Current hip replacement femoral implants are made of fully solid materials which all have stiffness considerably higher than that of bone. This mechanical mismatch can cause significant bone resorption secondary to stress shielding, which can lead to serious complications such as peri-prosthetic fracture during or after revision surgery. In this work, a high strength fully porous material with tunable mechanical properties is introduced for use in hip replacement design. The implant macro geometry is based off of a short stem taper-wedge implant compatible with minimally invasive hip replacement surgery. The implant micro-architecture is fine-tuned to locally mimic bone tissue properties which results in minimum bone resorption secondary to stress shielding. We present a systematic approach for the design of a 3D printed fully porous hip implant that encompasses the whole activity spectrum of implant development, from concept generation, multiscale mechanics of porous materials, material architecture tailoring, to additive manufacturing, and performance assessment via in vitro experiments in composite femurs. We show that the fully porous implant with an optimized material micro-structure can reduce the amount of bone loss secondary to stress shielding by 75% compared to a fully solid implant. This result also agrees with those of the in vitro quasi-physiological experimental model and the corresponding finite element model for both the optimized fully porous and fully solid implant. These studies demonstrate the merit and the potential of tuning material architecture to achieve a substantial reduction of bone resorption secondary to stress shielding. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1774-1783, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  18. Is Contralateral Templating Reliable for Establishing Rotational Alignment During Intramedullary Stabilization of Femoral Shaft Fractures? A Study of Individual Bilateral Differences in Femoral Version.

    Science.gov (United States)

    Croom, William P; Lorenzana, Daniel J; Auran, Richard L; Cavallero, Matthew J; Heckmann, Nathanael; Lee, Jackson; White, Eric A

    2018-02-01

    To determine native individual bilateral differences (IBDs) in femoral version in a diverse population. Computed tomography scans with complete imaging of uninjured bilateral femora were used to determine femoral version and IBDs in version. Age, sex, and ethnicity of each subject were also collected. Femoral version and IBDs in version were correlated with demographic variables using univariate and multivariate regression models. One hundred sixty-four subjects were included in the study. The average femoral version was 9.4 degrees (±9.4 degrees). The mean IBD in femoral version was 5.4 degrees (±4.4 degrees, P alignment during intramedullary stabilization of diaphyseal femur fractures. This is also an important consideration when considering malrotation of femur fractures because most studies define malrotation as a greater than 10-15-degree difference compared with the contralateral side. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  19. Proximal Focal Femoral Deficiency in Ibadan a Developing ...

    African Journals Online (AJOL)

    The cultural aversion to amputation in our environment makes it difficult to employ that option of treatment. Proximal focal femoral deficiency in Ibadan a developing country's perspective and a review of the literature. Keywords: Proximal focal femoral deficiency , congenital malformations , limb malformations , lower limb ...

  20. Femoral neck radiography: effect of flexion on visualization

    International Nuclear Information System (INIS)

    Garry, S.C.; Jhangri, G.S.; Lambert, R.G.W.

    2005-01-01

    To determine whether flexion improves radiographic visualization of the femoral neck when the femur is externally rotated. Five human femora, with varying neck-shaft and anteversion angles, were measured and immobilized. Degree of flexion required to bring the femoral neck horizontal was measured, varying the rotation. Next, one bone was radiographed in 16 positions, varying rotation in 15 o and flexion in 10 o increments. Radiographs were presented in randomized blinded fashion to 15 staff radiologists for scoring of femoral neck visualization. Following this, all 5 bones were radiographed in 4 positions of rotation and at 0 o and 20 o flexion, and blinded randomized review of radiographs was repeated. Comparisons between angles and rotations were made using the Mann-Whitney test. The flexion angle required to bring the long axis of the femoral neck horizontal correlated directly with the degree of external rotation (ρ o internal rotation to 30 o external rotation (ρ o flexion was applied to bones in external rotation, visualization significantly improved at 15 o (ρ o (ρ o ) of flexion can significantly improve radiographic visualization. This manoeuvre could be useful for radiography of the femoral neck when initial radiographs are inadequate because of external rotation of the leg. (author)

  1. Field-Induced Texturing of Ceramic Materials for Unparalleled Properties

    Science.gov (United States)

    2017-03-01

    Texturing of Ceramic Materials for Unparalleled Properties by...influence over many properties , such as optical transparency, strength, electrical conductivity, and piezoelectricity .19 Highly textured materials are... Ceramic Materials for Unparalleled Properties by Raymond Brennan, Victoria Blair, Nicholas Ku, Krista Limmer, Tanya Chantawansri, Mahesh

  2. Development and Demonstration of Material Properties Database and Software for the Simulation of Flow Properties in Cementitious Materials

    Energy Technology Data Exchange (ETDEWEB)

    Smith, F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Flach, G. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-03-30

    This report describes work performed by the Savannah River National Laboratory (SRNL) in fiscal year 2014 to develop a new Cementitious Barriers Project (CBP) software module designated as FLOExcel. FLOExcel incorporates a uniform database to capture material characterization data and a GoldSim model to define flow properties for both intact and fractured cementitious materials and estimate Darcy velocity based on specified hydraulic head gradient and matric tension. The software module includes hydraulic parameters for intact cementitious and granular materials in the database and a standalone GoldSim framework to manipulate the data. The database will be updated with new data as it comes available. The software module will later be integrated into the next release of the CBP Toolbox, Version 3.0. This report documents the development efforts for this software module. The FY14 activities described in this report focused on the following two items that form the FLOExcel package; 1) Development of a uniform database to capture CBP data for cementitious materials. In particular, the inclusion and use of hydraulic properties of the materials are emphasized; and 2) Development of algorithms and a GoldSim User Interface to calculate hydraulic flow properties of degraded and fractured cementitious materials. Hydraulic properties are required in a simulation of flow through cementitious materials such as Saltstone, waste tank fill grout, and concrete barriers. At SRNL these simulations have been performed using the PORFLOW code as part of Performance Assessments for salt waste disposal and waste tank closure.

  3. Femoral Component External Rotation Affects Knee Biomechanics: A Computational Model of Posterior-stabilized TKA.

    Science.gov (United States)

    Kia, Mohammad; Wright, Timothy M; Cross, Michael B; Mayman, David J; Pearle, Andrew D; Sculco, Peter K; Westrich, Geoffrey H; Imhauser, Carl W

    2018-01-01

    The correct amount of external rotation of the femoral component during TKA is controversial because the resulting changes in biomechanical knee function associated with varying degrees of femoral component rotation are not well understood. We addressed this question using a computational model, which allowed us to isolate the biomechanical impact of geometric factors including bony shapes, location of ligament insertions, and implant size across three different knees after posterior-stabilized (PS) TKA. Using a computational model of the tibiofemoral joint, we asked: (1) Does external rotation unload the medial collateral ligament (MCL) and what is the effect on lateral collateral ligament tension? (2) How does external rotation alter tibiofemoral contact loads and kinematics? (3) Does 3° external rotation relative to the posterior condylar axis align the component to the surgical transepicondylar axis (sTEA) and what anatomic factors of the femoral condyle explain variations in maximum MCL tension among knees? We incorporated a PS TKA into a previously developed computational knee model applied to three neutrally aligned, nonarthritic, male cadaveric knees. The computational knee model was previously shown to corroborate coupled motions and ligament loading patterns of the native knee through a range of flexion. Implant geometries were virtually installed using hip-to-ankle CT scans through measured resection and anterior referencing surgical techniques. Collateral ligament properties were standardized across each knee model by defining stiffness and slack lengths based on the healthy population. The femoral component was externally rotated from 0° to 9° relative to the posterior condylar axis in 3° increments. At each increment, the knee was flexed under 500 N compression from 0° to 90° simulating an intraoperative examination. The computational model predicted collateral ligament forces, compartmental contact forces, and tibiofemoral internal/external and

  4. Quantitative CT assessment of proximal femoral bone density. An experimental study concerning its correlation to breaking load for femoral neck fractures

    International Nuclear Information System (INIS)

    Buitrago-Tellez, C.H.; Schulze, C.; Gufler, H.; Langer, M.; Bonnaire, F.; Hoenninger, A.; Kuner, E.

    1997-01-01

    Purpose: In an experimental study, the correlation between the trabecular bone density of the different regions of the proximal femur and the fracture load in the setting of femoral neck fractures was examined. Methods: The bone mineral density 41 random proximal human femora was estimated by single-energy quanitative CT (SE-QCT). The trabecular bone density was measured at the greatest possible extracortical volume at midcapital, midneck and intertrochanteric level and in the 1 cm 3 volumes of the centres of these regions in a standardised 10 mm thick slice in the middle of the femoral neck axis (in mg/ml Ca-hydroxyl apatite). The proximal femora were then isolated and mounted on a compression/bending device under two-legged stand conditions and loaded up to the point when a femoral neck fracture occurred. Results: Statistical analysis revealed a linear correlation between the trabecular bone density and the fracture load for the greater regions, with the highest value in the maximal area of the head (coefficient factor r=0.76). Conclusion: According to our data, the measurement of the trabecular bone by SE-QCT at the femoral head is a more confident adjunct than the neck or trochanteric area to predict a femoral neck fracture. (orig.) [de

  5. Radionuclide patterns of femoral head disease

    Energy Technology Data Exchange (ETDEWEB)

    Webber, M M; Wagner, J; Cragin, M D [California Univ., Los Angeles (USA). Dept. of Radiological Sciences

    1977-12-01

    The pattern of uptake of bone marrow specific radio-sup(99m)Tc sulfur colloid and the pattern of uptake of bone mineral specific radio-sup(99m)Tc pryophosphate may be valuable in assessing bone vascularity in diseases suspected of causing impaired blood supply, or indicate the presence of reactive bone formation. The low energy of the technetium label has been shown to be superior to /sup 18/F and /sup 85/Sr, and leads to greater imaging detail on the scans. Femoral head scanning with mineral and/or marrow specific radionuclides offers the clinician a method of evaluating the status of the femoral head and possibly an early diagnosis of avascular necrosis before roentgenographic changes occur. This study, which reports on a 5-year experience using radionuclide scanning to assess femoral head vascularity, begins with baseline or normal studies followed by variations of the normal pattern. Typical scan patterns of hip pathology described above are also presented.

  6. Material Properties at Low Temperature

    International Nuclear Information System (INIS)

    Duthil, P

    2014-01-01

    From ambient down to cryogenic temperatures, the behaviour of materials changes greatly. Mechanisms leading to variations in electrical, thermal, mechanical, and magnetic properties in pure metals, alloys, and insulators are briefly introduced from a general engineering standpoint. Data sets are provided for materials commonly used in cryogenic systems for design purposes

  7. Material Properties at Low Temperature

    CERN Document Server

    Duthil, P

    2014-07-17

    From ambient down to cryogenic temperatures, the behaviour of materials changes greatly. Mechanisms leading to variations in electrical, thermal, mechanical, and magnetic properties in pure metals, alloys, and insulators are briefly introduced from a general engineering standpoint. Data sets are provided for materials commonly used in cryogenic systems for design purposes.

  8. Material Properties at Low Temperature

    Energy Technology Data Exchange (ETDEWEB)

    Duthil, P [Orsay, IPN (France)

    2014-07-01

    From ambient down to cryogenic temperatures, the behaviour of materials changes greatly. Mechanisms leading to variations in electrical, thermal, mechanical, and magnetic properties in pure metals, alloys, and insulators are briefly introduced from a general engineering standpoint. Data sets are provided for materials commonly used in cryogenic systems for design purposes.

  9. Wear and creep of highly crosslinked polyethylene against cobalt chrome and ceramic femoral heads.

    Science.gov (United States)

    Galvin, A L; Jennings, L M; Tipper, J L; Ingham, E; Fisher, J

    2010-10-01

    The wear and creep characteristics of highly crosslinked ultrahigh-molecular-weight polyethylene (UHMWPE) articulating against large-diameter (36mm) ceramic and cobalt chrome femoral heads have been investigated in a physiological anatomical hip joint simulator for 10 million cycles. The crosslinked UHMWPE/ceramic combination showed higher volume deformation due to creep plus wear during the first 2 million cycles, and a steady-state wear rate 40 per cent lower than that of the crosslinked UHMWPE/cobalt chrome combination. Wear particles were isolated and characterized from the hip simulator lubricants. The wear particles were similar in size and morphology for both head materials. The particle isolation methodology used could not detect a statistically significant difference between the particles produced by the cobalt chrome and alumina ceramic femoral heads.

  10. Individualised distal femoral cut improves femoral component placement and limb alignment during total knee replacement in knees with moderate and severe varus deformity.

    Science.gov (United States)

    Palanisami, Dhanasekararaja; Iyyampillai, Geethan; Shanmugam, Sivaraj; Natesan, Rajkumar; S, Rajasekaran

    2016-10-01

    Our aim was to determine the variation in valgus correction angle and the influence of individualised distal femoral cut on femoral component placement and limb alignment during total knee replacement (TKR) in knees with varus deformity. The study was done prospectively in two stages. In the first stage, the valgus correction angle (VCA) was calculated in long-limb radiographs of 227 patients and correlated with pre-operative parameters of femoral bowing, neck-shaft angle and hip-knee-ankle angle. In the second part comprising of 240 knees with varus deformity, 140 (group 1) had the distal femoral cut individualised according to the calculated VCA, while the remaining 100 knees (group 1) were operated with a fixed distal femoral cut of 5°. The outcome of surgery was studied by grouping the knees as varus 15°. Of the 227 limbs analysed in stage I, 70 knees (31 %) had a VCA angle outside 5-7°. Coronal bowing (p shaft angle (p alignment when VCA was individualised in the groups of knees with varus 10-15° (p 0.002) and varus >15° (p 0.002). Valgus correction angle is highly variable and is influenced by femoral bowing, neck-shaft angle and pre-operative deformity. Individualisation of VCA is preferable in patients with moderate and severe varus deformity. Level 2.

  11. Biophysical stimulation in osteonecrosis of the femoral head

    Directory of Open Access Journals (Sweden)

    Massari Leo

    2009-01-01

    Full Text Available Osteonecrosis of the femoral head is the endpoint of a disease process that results from insufficient blood flow and bone-tissue necrosis, leading to joint instability, collapse of the femoral head, arthritis of the joint, and total hip replacement. Pain is the most frequent clinical symptom. Both bone tissue and cartilage suffer when osteonecrosis of the femoral head develops. Stimulation with pulsed electromagnetic fields (PEMFs has been shown to be useful for enhancing bone repair and for exerting a chondroprotective effect on articular cartilage. Two Italian studies on the treatment of avascular necrosis of the femoral head with PEMFs were presented in this review. In the first study, 68 patients suffering from avascular necrosis of the femoral head were treated with PEMFs in combination with core decompression and autologous bone grafts. The second one is a retrospective analysis of the results of treatment with PEMFs of 76 hips in 66 patients with osteonecrosis of the femoral head. In both studies clinical information and diagnostic imaging were collected at the beginning of the treatment and at the time of follow up. Statistical analysis was performed using chi-square test. Both authors hypothesize that the short-term effect of PEMF stimulation may be to protect the articular cartilage from the catabolic effect of inflammation and subchondral bone-marrow edema. The long-term effect of PEMF stimulation may be to promote osteogenic activity at the necrotic area and prevent trabecular fracture and subchondral bone collapse. PEMF stimulation represents an important therapeutic opportunity to resolve the Ficat stage-I or II disease or at least to delay the time until joint replacement becomes necessary.

  12. [Femoral arteriovenous fistula: a late uncommon complication of central venous catheterization].

    Science.gov (United States)

    Conz, P A; Malagoli, A; Normanno, M; Munaro, D

    2007-01-01

    A 77-year-old woman was admitted due to AV graft thrombosis; given the technical impossibility of performing other native AV fistulas, we chose to insert a tunnelled central venous catheter. Considering the vascular history of the patient, the central venous catheter could not be placed into the internal jugular vein; it was therefore put into the left femoral vein. Following a 3-month-period of the catheter working properly, the patient was hospitalized due to sudden acute pain in the left thigh. In a few days the patient developed an important haematoma with serious anemization in the left lower limb. Ultrasonography showed the presence of a fistula between the left common femoral artery and the femoral vein, leading to the subsequent successful positioning of a stent into the common femoral artery through right trans-femoral access. Angiography examination showed the femoral vein patency along the proximal stretch with respect to the function of the tunnelled venous catheter.

  13. Diffuse scattering and the fundamental properties of materials

    CERN Document Server

    EIce, Gene; Barabash, Rozaliya

    2009-01-01

    Diffuse Scattering-the use of off-specular X-Rays and neutrons from surfaces and interfaces-has grown rapidly as a tool for characterizing the surface properties of materials and related fundamental structural properties. It has proven to be especially useful in the understanding of local properties within materials. This book reflects the efforts of physicists and materials scientists around the world who have helped to refine the techniques and applications of diffuse scattering. Major topics specifically covered include: -- Scattering in Low Dimensions -- Elastic and Thermal Diffuse Scattering from Alloys -- Scattering from Complex and Disordered Materials -- Scattering from Distorted Crystals.

  14. Avascular osteonecrosis of the femoral condyle after arthroscopic surgery

    International Nuclear Information System (INIS)

    Al-Kaar, M.; Garcia, J.; Fritschy, D.; Bonvin, J.C.

    1997-01-01

    Avascular osteonecrosis of the femoral condyle after arthroscopic surgery. Retrospective review of 10 patients who presented with avascular necrosis of the ipsilateral femoral condyle following arthroscopic meniscectomy (9 medial, 1 lateral). The bone lesions were evaluated by radiography and MRI, which were repeated for few patients. MRI allows earlier diagnosis of avascular necrosis of the femoral condyle and offers an evaluation of extent of the lesions whose evolution is variable: 3 patients required a knee prosthesis, the other 7 patients were treated medically. (authors)

  15. Research and advancement of treating avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Wang Kaibing; Bai Bin; Wang Honghui; Sui Hong

    2006-01-01

    To undertake retrospective analysis of the research and advancement of treating avascular necrosis of the femoral head. After comparing the superiority and inferiority of different treatments and the present therapeutic status many therapeutic methods for avascular necrosis of the femoral head have been performed, commonly according to the staging of necrosis. Conservative therapy is suitable for stage 0-I, interventional therapy is suitable for stage II-III, operation is adapted for stage II-III and femoral head collapse or degenerative changes. Avascular necrosis of the femoral head is a chronic and dysfunctional illness. Comprehensive treatment according to different stage is now the most popular. Interventional therapy is the study focus of the avascular necrosis of the femoral head meanwhile. (authors)

  16. 3D-Printed Patient-Specific ACL Femoral Tunnel Guide from MRI.

    Science.gov (United States)

    Rankin, Iain; Rehman, Haroon; Frame, Mark

    2018-01-01

    Traditional ACL reconstruction with non-anatomic techniques can demonstrate unsatisfactory long-term outcomes with regards instability and the degenerative knee changes observed with these results. Anatomic ACL reconstruction attempts to closely reproduce the patient's individual anatomic characteristics with the aim of restoring knee kinematics, in order to improve patient short and long-term outcomes. We designed an arthroscopic, patient-specific, ACL femoral tunnel guide to aid anatomical placement of the ACL graft within the femoral tunnel. The guide design was based on MRI scan of the subject's uninjured contralateral knee, identifying the femoral footprint and its anatomical position relative to the borders of the femoral articular cartilage. Image processing software was used to create a 3D computer aided design which was subsequently exported to a 3D-printing service. Transparent acrylic based photopolymer, PA220 plastic and 316L stainless steel patient-specific ACL femoral tunnel guides were created; the models produced were accurate with no statistical difference in size and positioning of the center of the ACL femoral footprint guide to MRI ( p =0.344, p =0.189, p =0.233 respectively). The guides aim to provide accurate marking of the starting point of the femoral tunnel in arthroscopic ACL reconstruction. This study serves as a proof of concept for the accurate creation of 3D-printed patient-specific guides for the anatomical placement of the femoral tunnel during ACL reconstruction.

  17. Femoral artery pseudoaneurysm as a complication of angioplasty. How can it be prevented?

    Science.gov (United States)

    Gupta, Prabha Nini; Salam Basheer, Abdul; Sukumaran, Gireesh Gomaty; Padmajan, Sabin; Praveen, Satheesan; Velappan, Praveen; Nair, Bigesh Unnikrishnan; Nair, Sandeep Govindan; Kunjuraman, Usha Kumari; Madthipat, Unnikrishnan; R, Jayadevan

    2013-01-01

    Femoral pseudoaneurysm is a common complication of repeated femoral puncture during cardiac catheterisation. We describe here the development of femoral pseudoaneurysms in a patient with Takayasu's arteritis, which healed in response to conservative treatment, and review the literature on the prevention and treatment of femoral pseudoaneurysm. PMID:27326111

  18. Static mechanical properties of buffer material

    International Nuclear Information System (INIS)

    Takaji, Kazuhiko; Suzuki, Hideaki

    1999-11-01

    The buffer material is expected to maintain its low water permeability, self-sealing properties, radionuclides adsorption and retardation properties, thermal conductivity, chemical buffering properties, overpack supporting properties, stress buffering properties, etc. over a long period of time. Natural clay is mentioned as a material that can relatively satisfy above. Among the kinds of natural clay, bentonite when compacted is superior because (i) it has exceptionally low water permeability and properties to control the movement of water in buffer, (ii) it fills void spaces in the buffer and fractures in the host rock as it swells upon water uptake, (iii) it has the ability to exchange cations and to adsorb cationic radioelements. In order to confirm these functions for the purpose of safety assessment, it is necessary to evaluate buffer properties through laboratory tests and engineering-scale tests, and to make assessments based on the ranges in the data obtained. This report describes the procedures, test conditions, results and examinations on the buffer material of unconfined compression tests, one-dimensional consolidation tests, consolidated-undrained triaxial compression tests and consolidated-undrained triaxial creep tests that aim at getting hold of static mechanical properties. We can get hold of the relationship between the dry density and tensile stress etc. by Brazilian tests, between the dry density and unconfined compressive strength etc. by unconfined compression tests, between the consolidation stress and void ratio etc. by one-dimensional consolidation tests, the stress pass of each effective confining pressure etc. by consolidated-undrained triaxial compression tests and the axial strain rate with time of each axial stress etc. by consolidated-undrained triaxial creep tests. (author)

  19. Femoral head epiphysis growth and development among Chinese children aged 0-5 years.

    Science.gov (United States)

    Luo, Jiayou; Tang, Jin; Zhou, Libo; Zeng, Rong; Mou, Jinsong; Zhang, Lingli

    2009-05-01

    The aim of this study was to examine the pattern of femoral head epiphysis growth and development among Chinese children. Between January and December, 2007, we randomly sampled 1,450 healthy Chinese children (0-5 years old) from Hunan Provincial Children's Hospital in Changsha, Hunan, China. The diameter of femoral head epiphysis was measured by pelvic X-ray photography and processed by medical image processing software. The growth of femoral head epiphysis in girls was 2-3 months earlier than that in boys. The diameter of femoral head epiphysis increased with advancing age in both girls and boys, but the diameter of femoral head epiphysis in 2, 3, 4, 6, and 10-month-old girls was significantly larger than that in boys. Cubic regression equations between the diameter of femoral head epiphysis and age were created for boys and girls that could be used to predict the diameter of femoral head epiphysis. In conclusion, there was gender difference in femoral head epiphysis growth and development among Chinese children, and our prediction models will provide the guidance for early diagnosis of diseases related to the growth and development of the femoral head epiphysis.

  20. Preoperative sup(99m)Tc-MDP scintimetry of femoral neck fractures

    International Nuclear Information System (INIS)

    Holmberg, S.; Thorngren, K.-G.

    1984-01-01

    Preoperative sup(99m)Tc-MDP-scintimetry was performed in 117 patients with femoral neck fractures. Scintimetry was shown to be superior to visual evaluation. The ratio was calculated of the uptake in the femoral head of the fractured side over that in the unfractured side, with compensation for the increased trochanteric femoral activity found on the fractured side. A ratio above 0.90 correlated well with uneventful healing in both undisplaced and displaced fractures. Preoperative scintimetry is of great value in the choice of primary treatment of femoral neck fractures. (author)

  1. Case report - curved femoral osteotomy for management of medial patellar luxation

    DEFF Research Database (Denmark)

    Allpass, Maja; Miles, James Edward

    2015-01-01

    Medial patellaluxation kan forårsages af femoral varus hos hund. Førhen har patienter med excessiv femoralvarus været korrigeret ved en lateralt placeret femoral kile-ostektomi. Her præsenteres en case, hvor en buet osteotomi blev anvendt til behandling af medial patellaluxation.......Medial patellaluxation kan forårsages af femoral varus hos hund. Førhen har patienter med excessiv femoralvarus været korrigeret ved en lateralt placeret femoral kile-ostektomi. Her præsenteres en case, hvor en buet osteotomi blev anvendt til behandling af medial patellaluxation....

  2. The impact of high total cholesterol and high low-density lipoprotein on avascular necrosis of the femoral head in low-energy femoral neck fractures.

    Science.gov (United States)

    Zeng, Xianshang; Zhan, Ke; Zhang, Lili; Zeng, Dan; Yu, Weiguang; Zhang, Xinchao; Zhao, Mingdong; Lai, Zhicheng; Chen, Runzhen

    2017-02-17

    Avascular necrosis of the femoral head (AVNFH) typically constitutes 5 to 15% of all complications of low-energy femoral neck fractures, and due to an increasingly ageing population and a rising prevalence of femoral neck fractures, the number of patients who develop AVNFH is increasing. However, there is no consensus regarding the relationship between blood lipid abnormalities and postoperative AVNFH. The purpose of this retrospective study was to investigate the relationship between blood lipid abnormalities and AVNFH following the femoral neck fracture operation among an elderly population. A retrospective, comparative study was performed at our institution. Between June 2005 and November 2009, 653 elderly patients (653 hips) with low-energy femoral neck fractures underwent closed reduction and internal fixation with cancellous screws (Smith and Nephew, Memphis, Tennessee). Follow-up occurred at 1, 6, 12, 18, 24, 30, and 36 months after surgery. Logistic multi-factor regression analysis was used to assess the risk factors of AVNFH and to determine the effect of blood lipid levels on AVNFH development. Inclusion and exclusion criteria were predetermined to focus on isolated freshly closed femoral neck fractures in the elderly population. The primary outcome was the blood lipid levels. The secondary outcome was the logistic multi-factor regression analysis. A total of 325 elderly patients with low-energy femoral neck fractures (AVNFH, n = 160; control, n = 165) were assessed. In the AVNFH group, the average TC, TG, LDL, and Apo-B values were 7.11 ± 3.16 mmol/L, 2.15 ± 0.89 mmol/L, 4.49 ± 1.38 mmol/L, and 79.69 ± 17.29 mg/dL, respectively; all of which were significantly higher than the values in the control group. Logistic multi-factor regression analysis showed that both TC and LDL were the independent factors influencing the postoperative AVNFH within femoral neck fractures. This evidence indicates that AVNFH was significantly

  3. Is Assessment of Femoral Head Perfusion During Modified Dunn for Unstable Slipped Capital Femoral Epiphysis an Accurate Indicator of Osteonecrosis?

    Science.gov (United States)

    Novais, Eduardo N; Sink, Ernest L; Kestel, Lauryn A; Carry, Patrick M; Abdo, João C M; Heare, Travis C

    2016-08-01

    The modified Dunn procedure, which is an open subcapital realignment through a surgical dislocation approach, has gained popularity for the treatment of unstable slipped capital femoral epiphysis (SCFE). Intraoperative monitoring of the femoral head perfusion has been recommended as a method of predicting osteonecrosis; however, the accuracy of this assessment has not been well documented. We asked (1) whether intraoperative assessment of femoral head perfusion would help identify hips at risk of developing osteonecrosis; (2) whether one of the four methods of assessment of femoral head perfusion is more accurate (highest area under the curve) at identifying hips at risk of osteonecrosis; and (3) whether specific clinical features would be associated with osteonecrosis occurrence after a modified Dunn procedure for unstable SCFE. Between 2007 and 2014, we performed 29 modified Dunn procedures for unstable SCFE (16 boys, 11 girls; median age, 13 years; range, 8-17 years); two were lost to followup before 1 year. During this period, six patients with unstable SCFE were treated by other procedures. All patients undergoing modified Dunn underwent assessment of epiphyseal perfusion by the presence of active bleeding and/or by intracranial pressure (ICP) monitoring. In the initial five patients perfusion was recorded once, either before dissection of the retinacular flap or after fixation by one of the two methods. In the remaining 22 patients (81%), perfusion was systematically assessed before dissection of the retinacular flap and after fixation by both methods. Minimum followup was 1 year (median, 2.5 years; range, 1-8 years) because osteonecrosis typically develops within the first year after surgery. Patients were assessed for osteonecrosis by the presence of femoral head collapse at radiographs obtained every 3 months during the first year after surgery. Seven (26%) of the 27 patients developed osteonecrosis. Measures of diagnostic accuracy including sensitivity

  4. SiC/SiC Cladding Materials Properties Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Snead, Mary A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Katoh, Yutai [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Koyanagi, Takaaki [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Singh, Gyanender P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-08-01

    When a new class of material is considered for a nuclear core structure, the in-pile performance is usually assessed based on multi-physics modeling in coordination with experiments. This report aims to provide data for the mechanical and physical properties and environmental resistance of silicon carbide (SiC) fiber–reinforced SiC matrix (SiC/SiC) composites for use in modeling for their application as accidenttolerant fuel cladding for light water reactors (LWRs). The properties are specific for tube geometry, although many properties can be predicted from planar specimen data. This report presents various properties, including mechanical properties, thermal properties, chemical stability under normal and offnormal operation conditions, hermeticity, and irradiation resistance. Table S.1 summarizes those properties mainly for nuclear-grade SiC/SiC composites fabricated via chemical vapor infiltration (CVI). While most of the important properties are available, this work found that data for the in-pile hydrothermal corrosion resistance of SiC materials and for thermal properties of tube materials are lacking for evaluation of SiC-based cladding for LWR applications.

  5. Proximal focal femoral deficiency: evaluation by MR imaging

    International Nuclear Information System (INIS)

    Biko, David M.; Davidson, Richard; Pena, Andres; Jaramillo, Diego

    2012-01-01

    Proximal focal femoral deficiency (PFFD) is a rare congenital anomaly characterized by abnormal development of the proximal femur. The most common radiographic classification (Aitken) does not evaluate the cartilaginous and soft-tissue abnormalities. To demonstrate MR findings of PFFD focusing on features not seen with radiographs. Nine MR examinations of the hip and femurs of seven children with PFFD were retrospectively reviewed. Imaging was quantitatively and qualitatively assessed comparing the affected limb to the contralateral limb and age-matched controls. The children were classified via the Aitken classification. All children had at least mild acetabular dysplasia, and one type D patient had no acetabulum. MR demonstrated that 4/6 children had labral hypertrophy with a decreased distance from the greater trochanter to the acetabular rim, suggesting impingement (P < 0.05). The proximal femoral physis was abnormal in all cases. The connection between the femoral head and shaft if present was fibrous or fibrocartilaginous. MRI can help in evaluation of PFFD by defining the anatomy. MR demonstrates features of the acetabulum and cartilaginous femoral epiphysis and depicts ligamentous abnormalities of the knee. (orig.)

  6. Proximal focal femoral deficiency: evaluation by MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Biko, David M. [National Naval Medical Center, Department of Radiology, Bethesda, MD (United States); Uniformed Services University of Health Sciences, Department of Radiology and Radiological Sciences, Bethesda, MD (United States); Davidson, Richard [The Children' s Hospital of Philadelphia, Department of Orthopedic Surgery, Philadelphia, PA (United States); Pena, Andres; Jaramillo, Diego [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2012-01-15

    Proximal focal femoral deficiency (PFFD) is a rare congenital anomaly characterized by abnormal development of the proximal femur. The most common radiographic classification (Aitken) does not evaluate the cartilaginous and soft-tissue abnormalities. To demonstrate MR findings of PFFD focusing on features not seen with radiographs. Nine MR examinations of the hip and femurs of seven children with PFFD were retrospectively reviewed. Imaging was quantitatively and qualitatively assessed comparing the affected limb to the contralateral limb and age-matched controls. The children were classified via the Aitken classification. All children had at least mild acetabular dysplasia, and one type D patient had no acetabulum. MR demonstrated that 4/6 children had labral hypertrophy with a decreased distance from the greater trochanter to the acetabular rim, suggesting impingement (P < 0.05). The proximal femoral physis was abnormal in all cases. The connection between the femoral head and shaft if present was fibrous or fibrocartilaginous. MRI can help in evaluation of PFFD by defining the anatomy. MR demonstrates features of the acetabulum and cartilaginous femoral epiphysis and depicts ligamentous abnormalities of the knee. (orig.)

  7. Planning for corrective osteotomy of the femoral bone using 3D-modeling. Part I

    Directory of Open Access Journals (Sweden)

    Alexey G Baindurashvili

    2016-09-01

    Full Text Available Introduction. In standard planning for corrective hip osteotomy, a surgical intervention scheme is created on a uniplanar paper medium on the basis of X-ray images. However, uniplanar skiagrams are unable to render real spatial configuration of the femoral bone. When combining three-dimensional and uniplanar models of bone, human errors inevitably occur, causing the distortion of preset parameters, which may lead to glaring errors and, as a result, to repeated operations. Aims. To develop a new three-dimensional method for planning and performing corrective osteotomy of the femoral bone, using visualizing computer technologies. Materials and methods. A new method of planning for corrective hip osteotomy in children with various hip joint pathologies was developed. We examined the method using 27 patients [aged 5–18 years (32 hip joints] with congenital and acquired femoral bone deformation. The efficiency of the proposed method was assessed in comparison with uniplanar planning using roentgenograms. Conclusions. Computerized operation planning using three-dimensional modeling improves treatment results by minimizing the likelihood of human errors and increasing planning and surgical intervention  accuracy.

  8. Reoperation Rates for Laparoscopic vs Open Repair of Femoral Hernias in Denmark

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Bisgaard, Thue; Kehlet, Henrik

    2014-01-01

    IMPORTANCE: In Denmark approximately 10 000 groin hernias are repaired annually, of which 2% to 4% are femoral hernias. Several methods for repair of femoral hernias are used including sutured repair and different types of mesh repair with either open or laparoscopic techniques. The use of many...... laparoscopic vs open femoral hernia repair, analyzing data from a nationwide database. DESIGN, SETTING, AND PARTICIPANTS: A prospective cohort study was conducted. Data on femoral hernia repairs registered in the Danish Hernia Database from January 1998 until February 2012 were extracted and analyzed. All...... repairs were followed in the database and analyzed for reports of reoperation, which were used as a proxy for recurrence. Femoral hernia recurrence and inguinal hernia occurrence after the index repair were analyzed. EXPOSURE: Repair of a femoral hernia. MAIN OUTCOMES AND MEASURES: Reoperation...

  9. Radiographic anatomy of the proximal femur: femoral neck fracture vs. transtrochanteric fracture

    Directory of Open Access Journals (Sweden)

    Ana Lecia Carneiro Leão de Araújo Lima

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the correlation between radiographic parameters of the proximal femur with femoral neck fractures or transtrochanteric fractures. METHODS: Cervicodiaphyseal angle (CDA, femoral neck width (FNW, hip axis length (HAL, and acetabular tear drop distance (ATD were analyzed in 30 pelvis anteroposterior view X-rays of patients with femoral neck fractures (n = 15 and transtrochanteric fractures (n = 15. The analysis was performed by comparing the results of the X-rays with femoral neck fractures and with transtrochanteric fractures. RESULTS: No statistically significant differences between samples were observed. CONCLUSION: There was no correlation between radiographic parameters evaluated and specific occurrence of femoral neck fractures or transtrochanteric fractures.

  10. Evaluation of femoral head vascularization in slipped capital femoral epiphysis before and after cannulated screw fixation with use of contrast-enhanced MRI: initial results

    International Nuclear Information System (INIS)

    Staatz, G.; Honnef, D.; Hohl, C.; Schmidt, T.; Guenther, R.W.; Kochs, A.; Roehrig, H.

    2007-01-01

    In this study we used contrast-enhanced magnetic resonance imaging (MRI) to evaluate the vascularization of the femoral head in children with slipped capital femoral epiphysis (SCFE) before and after cannulated screw fixation. Eleven consecutive children with SCFE, seven boys and four girls, aged 10-15 years were included in the study. There were no preslips; four children had acute, three acute-on-chronic, and four chronic SCFE. The MRI examinations were performed in a 1.5 Tesla MR scanner with use of a coronal STIR sequence, a coronal contrast-enhanced T1-weighted spin-echo sequence, and a sagittal three-dimensional gradient-echo sequence. Morphology, signal intensities, and contrast-enhancement of the femoral head were assessed by two radiologists in consensus. Morphologic distortion of the physis, bone marrow edema within the metaphysis and epiphysis, and joint effusion were the preoperative MRI findings of SCFE in each child. In nine children, the vascularization of the femoral head before and after surgery was normal. In one child, a preoperative avascular zone in the superolateral aspect of the epiphysis revascularized completely after surgery. One child with severe SCFE developed avascular necrosis of the femoral head after open reduction of the slip. We conclude that MRI allows for accurate evaluation of the femoral head vascularization before and after surgery in children with SCFE. (orig.)

  11. Evaluation of femoral head vascularization in slipped capital femoral epiphysis before and after cannulated screw fixation with use of contrast-enhanced MRI: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Staatz, G. [Friedrich-Alexander-University Erlangen-Nuernberg, Department of Radiology, Division of Pediatric Radiology, Erlangen (Germany); University Hospital of the RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Honnef, D.; Hohl, C.; Schmidt, T.; Guenther, R.W. [University Hospital of the RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Kochs, A.; Roehrig, H. [University Hospital of the RWTH Aachen, Department of Orthopaedic Surgery, Aachen (Germany)

    2007-01-15

    In this study we used contrast-enhanced magnetic resonance imaging (MRI) to evaluate the vascularization of the femoral head in children with slipped capital femoral epiphysis (SCFE) before and after cannulated screw fixation. Eleven consecutive children with SCFE, seven boys and four girls, aged 10-15 years were included in the study. There were no preslips; four children had acute, three acute-on-chronic, and four chronic SCFE. The MRI examinations were performed in a 1.5 Tesla MR scanner with use of a coronal STIR sequence, a coronal contrast-enhanced T1-weighted spin-echo sequence, and a sagittal three-dimensional gradient-echo sequence. Morphology, signal intensities, and contrast-enhancement of the femoral head were assessed by two radiologists in consensus. Morphologic distortion of the physis, bone marrow edema within the metaphysis and epiphysis, and joint effusion were the preoperative MRI findings of SCFE in each child. In nine children, the vascularization of the femoral head before and after surgery was normal. In one child, a preoperative avascular zone in the superolateral aspect of the epiphysis revascularized completely after surgery. One child with severe SCFE developed avascular necrosis of the femoral head after open reduction of the slip. We conclude that MRI allows for accurate evaluation of the femoral head vascularization before and after surgery in children with SCFE. (orig.)

  12. Delayed appearance of hypaesthesia and paralysis after femoral nerve block

    OpenAIRE

    Stefan Landgraeber; Thomas Albrecht; Ulrich Reischuck; Marius von Knoch

    2012-01-01

    We report on a female patient who underwent an arthroscopy of the right knee and was given a continuous femoral nerve block catheter. The postoperative course was initially unremarkable, but when postoperative mobilisation was commenced, 18 hours after removal of the catheter, the patient noticed paralysis and hypaesthesia. Examination confirmed the diagnosis of femoral nerve dysfunction. Colour duplex sonography of the femoral artery and computed tomography of the lumbar spine and pelvis yie...

  13. Research of footwear lining materials thermoconductive properties

    Science.gov (United States)

    Maksudova, U.; Ilkhamova, M.; Mirzayev, N.; Pazilova, D.

    2017-11-01

    Protective properties of footwear are influenced by a number of factors and the most important of them are: design features of the top and the bottom of the footwear, it’s shape, physical and mechanical properties of the components of which they are made. In course of work there were researched thermoconductive properties of different lining membrane materials used for production of high temperature protective footwear. Research results allow to select the appropriate materials by reference to thermoconductive properties during design of protective footwear for extreme conditions to prolong the wearer’s time of comfortable stay in conditions of exposure of elevated temperatures to a stack.

  14. Spectroscopic properties of rare earths in optical materials

    CERN Document Server

    Parisi, Jürgen; Osgood, R; Warlimont, Hans; Liu, Guokui; Jacquier, Bernard

    2005-01-01

    Aimed at researchers and graduate students, this book provides up-to-date information for understanding electronic interactions that impact the optical properties of rare earth ions in solids. Its goal is to establish a connection between fundamental principles and the materials properties of rare-earth activated luminescent and laser optical materials. The theoretical survey and introduction to spectroscopic properties include electronic energy level structure, intensities of optical transitions, ion-phonon interactions, line broadening, and energy transfer and up-conversion. An important aspect of the book lies in its deep and detailed discussions on materials properties and the potential of new applications such as optical storage, information processing, nanophotonics, and molecular probes that have been identified in recent experimental studies. This volume will be a valuable reference book on advanced topics of rare earth spectroscopy and materials science.

  15. [Comparison of in vivo characteristics of polyethylene wear particles produced by a metal and a ceramic femoral component in total knee replacement].

    Science.gov (United States)

    Veigl, D; Vavřík, P; Pokorný, D; Slouf, M; Pavlova, E; Landor, I

    2011-01-01

    The aim of the study was to evaluate in vivo and compare, in terms of the quality and number of ultra high-molecular polyethylene (UHMWPE) wear particles, total knee replacements of identical construction differing only in the material used for femoral component production, i.e., CoCrMo alloy or ZrO2 ceramics. Samples of peri-prosthetic granuloma tissue were collected in two patients with total knee replacement suffering from implant migration, who were matched in relevant characteristics. The primary knee replacement in Patient 1 with a CoCrMo femoral component was done 7.2 years and in Patient 2 with a ZrO2 implant 6.8 years before this assessment. The polyethylene wear-induced granuloma was analysed by the MORF method enabling us to assess the shape and size of wear debris and the IRc method for assessment of particle concentration. In the granuloma tissue samples of Patient 1, on the average, particles were 0.30 mm in size and their relative volume was 0.19. In the Patient 2 tissue samples, the average size of particles was 0.33 mm and their relative volume was 0.26. There was no significant difference in either particle morphology or their concentration in the granuloma tissue between the two patients. One of the options of how to reduce the production of polyethylene wear particles is to improve the tribological properties of contacting surfaces in total knee replacement by substituting a cobalt-chrome femoral component with a zirconia ceramic femoral component. The previous in vitro testing carried out with a mechanical simulator under conditions approaching real weight-bearing in the human body did show a nearly three-fold decrease in the number of UHMWPE wear particles in zirconia components. The evaluation of granuloma tissue induced by the activity of a real prosthetic joint for nearly seven years, however, did not reveal any great difference in either quality or quantity of polyethylene debris between the two replacements. The difference of surface

  16. Amorphous and nanocrystalline materials preparation, properties, and applications

    CERN Document Server

    Inoue, A

    2001-01-01

    Amorphous and nanocrystalline materials are a class of their own. Their properties are quite different to those of the corresponding crystalline materials. This book gives systematic insight into their physical properties, structure, behaviour, and design for special advanced applications.

  17. OUTCOME OF INTERTROCHANTERIC FRACTURES TREATED WITH SHORT FEMORAL NAIL

    Directory of Open Access Journals (Sweden)

    Yadkikar Shriniwas V, Yadkikar Vishnu S, Patel Mayank, Dhruvilkumar Gandhi, Kunkulol Rahul

    2015-07-01

    Full Text Available Aim: To study the functional and anatomical outcome of Inter trochanteric fractures of femur treated with Short femoral nail. Method: This was retrospective study carried out in which 60 patients (50 Male & 10 Female of 5th to 8th decade of life who underwent Short femoral nail fixation for both Stable & unstable Inter Trochanteric fractures. From the records each patient data was assessed for time required for mobilization, average fracture healing time, degree and grade of hip range of movements, complications, anatomical reduction achieved using Short femoral nail fixation. Results: 55 cases achieved Anatomical reduction. Good to Excellent Hip range of Motion was in 55 (90 % cases. Fracture union was seen in all cases. No evidence of Z Effect, AVN of femoral head, Implant failure, Fracture of femoral shaft below the Nail tip was seen in any case, However Reverse Z Effect was seen in 4 & shortening of less than 2 cm was seen in 2 cases, External rotation of 10 degree was seen in1 case. Average fracture Union time was 14 weeks. Conclusion: Short femoral nail appears to be better implant for fixation of both Stable & unstable Inter Trochanteric fractures as it fulfills the biomechanical demands being minimally invasive, less blood loss , it prevents excessive varus collapse at fracture site, produces less stress riser effect below the nail tip, Short operative time, Facilitates early mobilization & functional recovery of patients. But Anatomical fracture reduction & optimal implant placement are absolutely must for better results.

  18. Evaluation of a patient specific femoral alignment guide for hip resurfacing.

    Science.gov (United States)

    Olsen, Michael; Naudie, Douglas D; Edwards, Max R; Sellan, Michael E; McCalden, Richard W; Schemitsch, Emil H

    2014-03-01

    A novel alternative to conventional instrumentation for femoral component insertion in hip resurfacing is a patient specific, computed tomography based femoral alignment guide. A benchside study using cadaveric femora was performed comparing a custom alignment guide to conventional instrumentation and computer navigation. A clinical series of twenty-five hip resurfacings utilizing a custom alignment guide was conducted by three surgeons experienced in hip resurfacing. Using cadaveric femora, the custom guide was comparable to conventional instrumentation with computer navigation proving superior to both. Clinical femoral component alignment accuracy was 3.7° and measured within ± 5° of plan in 20 of 24 cases. Patient specific femoral alignment guides provide a satisfactory level of accuracy and may be a better alternative to conventional instrumentation for initial femoral guidewire placement in hip resurfacing. Crown Copyright © 2014. All rights reserved.

  19. Dose-Effect Relationships for Femoral Fractures After Multimodality Limb-Sparing Therapy of Soft-Tissue Sarcomas of the Proximal Lower Extremity

    Energy Technology Data Exchange (ETDEWEB)

    Pak, Daniel; Vineberg, Karen A. [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States); Griffith, Kent A. [Biostatistics Unit, Comprehensive Cancer Center, University of Michigan, Ann Arbor, MI (United States); Sabolch, Aaron [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States); Chugh, Rashmi [Department of Internal Medicine, Division of Hematology/Oncology, University of Michigan, Ann Arbor, MI (United States); Ben-Josef, Edgar [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States); Biermann, Janet Sybil [Department of Orthopedic Surgery, University of Michigan, Ann Arbor, MI (United States); Feng, Mary, E-mail: maryfeng@umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States)

    2012-07-15

    Purpose: We investigated the clinical and dosimetric predictors for radiation-associated femoral fractures in patients with proximal lower extremity soft tissue sarcomas (STS). Methods and Materials: We examined 131 patients with proximal lower extremity STS who received limb-sparing surgery and external-beam radiation therapy between 1985 and 2006. Five (4%) patients sustained pathologic femoral fractures. Dosimetric analysis was limited to 4 fracture patients with full three-dimensional dose information, who were compared with 59 nonfracture patients. The mean doses and volumes of bone (V{sub d}) receiving specified doses ({>=}30 Gy, 45 Gy, 60 Gy) at the femoral body, femoral neck, intertrochanteric region, and subtrochanteric region were compared. Clinical predictive factors were also evaluated. Results: Of 4 fracture patients in our dosimetric series, there were three femoral neck fractures with a mean dose of 57.6 {+-} 8.9 Gy, V30 of 14.5 {+-} 2.3 cc, V45 of 11.8 {+-} 1.1 cc, and V60 of 7.2 {+-} 2.2 cc at the femoral neck compared with 22.9 {+-} 20.8 Gy, 4.8 {+-} 5.6 cc, 2.5 {+-} 3.9 cc, and 0.8 {+-} 2.7 cc, respectively, for nonfracture patients (p < 0.03 for all). The femoral neck fracture rate was higher than at the subtrochanteric region despite lower mean doses at these subregions. All fracture sites received mean doses greater than 40 Gy. Also, with our policy of prophylactic femoral intramedullary nailing for high-risk patients, there was no significant difference in fracture rates between patients with and without periosteal excision. There were no significant differences in age, sex, tumor size, timing of radiation therapy, and use of chemotherapy between fracture and nonfracture patients. Conclusions: These dose-volume toxicity relationships provide RT optimization goals to guide future efforts for reducing pathologic fracture rates. Prophylactic femoral intramedullary nailing may also reduce fracture risk for susceptible patients.

  20. Dose–Effect Relationships for Femoral Fractures After Multimodality Limb-Sparing Therapy of Soft-Tissue Sarcomas of the Proximal Lower Extremity

    International Nuclear Information System (INIS)

    Pak, Daniel; Vineberg, Karen A.; Griffith, Kent A.; Sabolch, Aaron; Chugh, Rashmi; Ben-Josef, Edgar; Biermann, Janet Sybil; Feng, Mary

    2012-01-01

    Purpose: We investigated the clinical and dosimetric predictors for radiation-associated femoral fractures in patients with proximal lower extremity soft tissue sarcomas (STS). Methods and Materials: We examined 131 patients with proximal lower extremity STS who received limb-sparing surgery and external-beam radiation therapy between 1985 and 2006. Five (4%) patients sustained pathologic femoral fractures. Dosimetric analysis was limited to 4 fracture patients with full three-dimensional dose information, who were compared with 59 nonfracture patients. The mean doses and volumes of bone (V d ) receiving specified doses (≥30 Gy, 45 Gy, 60 Gy) at the femoral body, femoral neck, intertrochanteric region, and subtrochanteric region were compared. Clinical predictive factors were also evaluated. Results: Of 4 fracture patients in our dosimetric series, there were three femoral neck fractures with a mean dose of 57.6 ± 8.9 Gy, V30 of 14.5 ± 2.3 cc, V45 of 11.8 ± 1.1 cc, and V60 of 7.2 ± 2.2 cc at the femoral neck compared with 22.9 ± 20.8 Gy, 4.8 ± 5.6 cc, 2.5 ± 3.9 cc, and 0.8 ± 2.7 cc, respectively, for nonfracture patients (p < 0.03 for all). The femoral neck fracture rate was higher than at the subtrochanteric region despite lower mean doses at these subregions. All fracture sites received mean doses greater than 40 Gy. Also, with our policy of prophylactic femoral intramedullary nailing for high-risk patients, there was no significant difference in fracture rates between patients with and without periosteal excision. There were no significant differences in age, sex, tumor size, timing of radiation therapy, and use of chemotherapy between fracture and nonfracture patients. Conclusions: These dose–volume toxicity relationships provide RT optimization goals to guide future efforts for reducing pathologic fracture rates. Prophylactic femoral intramedullary nailing may also reduce fracture risk for susceptible patients.

  1. Metallurgy and properties of plasma spray formed materials

    Science.gov (United States)

    Mckechnie, T. N.; Liaw, Y. K.; Zimmerman, F. R.; Poorman, R. M.

    1992-01-01

    Understanding the fundamental metallurgy of vacuum plasma spray formed materials is the key to enhancing and developing full material properties. Investigations have shown that the microstructure of plasma sprayed materials must evolve from a powder splat morphology to a recrystallized grain structure to assure high strength and ductility. A fully, or near fully, dense material that exhibits a powder splat morphology will perform as a brittle material compared to a recrystallized grain structure for the same amount of porosity. Metallurgy and material properties of nickel, iron, and copper base alloys will be presented and correlated to microstructure.

  2. Chemical hydrogen storage material property guidelines for automotive applications

    Science.gov (United States)

    Semelsberger, Troy A.; Brooks, Kriston P.

    2015-04-01

    Chemical hydrogen storage is the sought after hydrogen storage media for automotive applications because of the expected low pressure operation (0.05 kg H2/kgsystem), and system volumetric capacities (>0.05 kg H2/Lsystem). Currently, the primary shortcomings of chemical hydrogen storage are regeneration efficiency, fuel cost and fuel phase (i.e., solid or slurry phase). Understanding the required material properties to meet the DOE Technical Targets for Onboard Hydrogen Storage Systems is a critical knowledge gap in the hydrogen storage research community. This study presents a set of fluid-phase chemical hydrogen storage material property guidelines for automotive applications meeting the 2017 DOE technical targets. Viable material properties were determined using a boiler-plate automotive system design. The fluid-phase chemical hydrogen storage media considered in this study were neat liquids, solutions, and non-settling homogeneous slurries. Material properties examined include kinetics, heats of reaction, fuel-cell impurities, gravimetric and volumetric hydrogen storage capacities, and regeneration efficiency. The material properties, although not exhaustive, are an essential first step in identifying viable chemical hydrogen storage material properties-and most important, their implications on system mass, system volume and system performance.

  3. Biomechanical properties of the femoral neck relative to osteosynthesis methods and bone mineral content assessed by computed tomography

    International Nuclear Information System (INIS)

    Husby, T.

    1990-01-01

    Bone mineral content as determined by computerized tomography (CT) and mechanical strength on axial loading were compared in 36 cadaveric femur specimens. Based on the CT measurements of density and area, the mass of a transverse slice of the femur was estimated. Highly significant correlations were demonstrated between strength and cancellous bone density. Even higher correlations were revealed when the bone masses of the proximal and distal femoral areas were calculated. Based on these findings, an equal distribution of the effective mass of the femur was postulated. This hypothesis was confirmed in an experimental rotational model. The CT attenuation values were also correlated to direct measurements of bone mineral content, i.e. calcium. Moreover, the strength of different metal implants, commonly used in femoral neck fractures, were assessed in cadaver specimens. 134 refs., 13 figs., 12 tabs

  4. Preparation and multi-properties determination of radium-containing rocklike material

    Science.gov (United States)

    Hong, Changshou; Li, Xiangyang; Zhao, Guoyan; Jiang, Fuliang; Li, Ming; Zhang, Shuai; Wang, Hong; Liu, Kaixuan

    2018-02-01

    The radium-containing rocklike material were fabricated using distilled water, ordinary Portland cement and additives mixed aggregates and admixtures according to certain proportion. The physico-mechanical properties as well as radioactive properties of the prepared rocklike material were measured. Moreover, the properties of typical granite sample were also investigated. It is found on one hand, similarities exist in physical and mechanical properties between the rocklike material and the granite sample, this confirms the validity of the proposed method; on the other hand, the rocklike material generally performs more remarkable radioactive properties compared with the granite sample, while radon diffusive properties in both materials are essentially matching. This study will provide a novel way to prepare reliable radium-containing samples for radon study of underground uranium mine.

  5. Aneurysm of the superficial femoral artery in an infant

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, M.; Komuro, H.; Matoba, K.; Kaneko, M. [Dept. of Paediatric Surgery, Inst. of Clinical Medicine, Univ. of Tsukuba, Ibaraki (Japan); Niitsu, M.; Itai, Y. [Dept. of Radiology, Inst. of Clinical Medicine, Univ. of Tsukuba, Ibaraki (Japan)

    2003-04-01

    An isolated arterial aneurysm in childhood is extremely rare. We report a 1-year-old girl with an aneurysm of the right superficial femoral artery, presenting as an asymptomatic mass of the thigh. The aneurysm involved the whole superficial femoral artery (9 cm in length), and surgical treatment would have required replacement of the affected artery. Conservative treatment was chosen, influenced by the patient's rapid growth at that time. Non-invasive, 3-D contrast-enhanced magnetic resonance angiography (MRA) was useful as an alternative to conventional angiography for detailed evaluation of the femoral arteries, including the aneurysm. (orig.)

  6. Valgus Slipped Capital Femoral Epiphysis in Patient with Hypopituitarism

    Directory of Open Access Journals (Sweden)

    Yoshihiro Kotoura

    2017-01-01

    Full Text Available Slipped capital femoral epiphysis (SCFE is a common disease of adolescent and the epiphysis is positioned more posteromedially in relation to the femoral neck shaft with varus SCFE; however, posterolateral displacement of the capital epiphysis, valgus SCFE, occurs less frequently. We report a case of valgus SCFE in a 17-year-old boy with hypopituitarism. After falling down, he experienced difficulty in walking. The radiographs were inconclusive; however three-dimensional computed tomography images showed lateral displacement of the epiphysis on the right femoral head. Valgus SCFE was diagnosed. The patient underwent in situ pinning of both sides. In situ pinning on the left side was performed as a prophylactic pinning because of endocrine abnormalities. At the 1-year follow-up, he could walk without any difficulty and there were no signs of pain. The epiphysis is commonly positioned more posteromedially in relation to the femoral neck shaft with most SCFE, but, in this case, the epiphysis slipped laterally. Differential diagnosis included femoral neck fracture (Delbet-Colonna type 1; however, this was less likely due to the absence of other clinical signs. Therefore, we diagnosed the patient as SCFE. When children complain of leg pain and limp, valgus SCFE that may not be visualized on anteroposterior radiographs needs to be considered.

  7. Magnetic materials. Properties and applications

    International Nuclear Information System (INIS)

    Bar'yakhtar, V.

    1998-01-01

    Main theoretical and experimental results of physics of magnetic materials have been stated. Special attention was paid to the problem of creation of magnetic materials for information recording and presentation. The results of fundamental researches have been considered for their effect on creation of magnetic materials with the properties required for production as well as the reverse effect of production financing on the development of fundamental investigations. The relations between the development of high technologies and the society requirements, financing volumes and the level of NIKOR. (author)

  8. Compartment Syndrome following Open Femoral Fracture with an Isolated Femoral Vein Injury Treated with Acute Repair

    Directory of Open Access Journals (Sweden)

    David Walmsley

    2014-01-01

    Full Text Available Acute compartment syndrome is a surgical emergency and its diagnosis is more difficult in obtunded or insensate patients. We present the case of a 34-year-old woman who sustained a Gustilo-Anderson grade III open midshaft femur fracture with an isolated femoral vein injury treated with direct repair. She developed lower leg compartment syndrome at 48 hours postoperatively, necessitating fasciotomies. She was subsequently found to have a DVT in her femoral vein at the level of the repair and was started on therapeutic anticoagulation. This case highlights the importance of recognition of isolated venous injuries in a trauma setting as a risk factor for developing compartment syndrome.

  9. Stem cell treatment for avascular necrosis of the femoral head: current perspectives

    Directory of Open Access Journals (Sweden)

    Houdek MT

    2014-04-01

    Full Text Available Matthew T Houdek,1 Cody C Wyles,2 John R Martin,1 Rafael J Sierra11Department of Orthopedic Surgery, 2School of Medicine, Mayo Clinic, Rochester, MN, USAAbstract: Avascular necrosis (AVN of the femoral head is a progressive disease that predominantly affects younger patients. Although the exact pathophysiology of AVN has yet to be elucidated, the disease is characterized by a vascular insult to the blood supply of the femoral head, which can lead to collapse of the femoral head and subsequent degenerative changes. If AVN is diagnosed in the early stages of the disease, it may be possible to attempt surgical procedures which preserve the hip joint, including decompression of the femoral head augmented with concentrated bone marrow. The use of autologous stem cells has shown promise in halting the progression of AVN of the femoral head, and subsequently preventing young patients from undergoing total hip arthroplasty. The purpose of this study was to review the current use of stem cells for the treatment of AVN of the femoral head.Keywords: avascular necrosis, femoral head, osteonecrosis, stem cells, concentrated bone marrow

  10. MR imaging of femoral marrow in treated β-thalassemia major

    International Nuclear Information System (INIS)

    Shen Jun; Liang Biling; Chen Jianyu; Zhao Jiquan; Xu Honggui; Chen Chun

    2006-01-01

    Objective: To investigate MR imaging features of femoral marrow in treated β-thalassemia major. Methods: MR imaging of the proximal femoral marrow was performed in 35 cases of β-thalassemia major and 45 age- and sex-matched normal children as control. Coronal images of femoral marrow with the techniques of spin echo and fast field echo (FFE) were obtained. On T 1 -weighted imaging the red and yellow femoral marrow were judged and marrow distribution was classified into five groups. The hemosiderosis of marrow was judged on the basis of signal intensity of marrow on FFE imaging. The marrow distribution classification and the hemosiderosis on MR imaging were correlated with clinical features. Results: On FFE, marrow hemosiderosis occurred in 15 patients with a marked hypo-intensity signal and was related to the age (P=0.032). On T 1 -weighted imaging, the femoral marrow in 35 patients was classified as group III and IV, while the marrow distribution was group I or II in all normal children, there was statistically significant difference (P<0.001). The marrow distribution correlated positively with blood transfusion (P=0.049). Conclusion: The red marrow hyperplasia and hemosiderosis could occur in the femoral marrow of the treated β-thalassemia major. The marrow hyperplasia on MR imaging was related to the blood transfusion, and the hemosiderosis related to the age. (authors)

  11. Osteoarthritis of the patella, lateral femoral condyle and posterior medial femoral condyle correlate with range of motion.

    Science.gov (United States)

    Suzuki, Takashi; Motojima, Sayaka; Saito, Shu; Ishii, Takao; Ryu, Keinosuke; Ryu, Junnosuke; Tokuhashi, Yasuaki

    2013-11-01

    The type of osteoarthritis and the degree of severity which causes restriction of knee range of motion (ROM) is still largely unknown. The objective of this study was to analyse the location and the degree of cartilage degeneration that affect knee range of motion and the connection, if any, between femorotibial angle (FTA) and knee ROM restriction. Four hundreds and fifty-six knees in 230 subjects with knee osteoarthritis undergoing knee arthroplasty were included. Articular surface was divided into eight sections, and cartilage degeneration was evaluated macroscopically during the operation. Cartilage degeneration was classified into four grades based on the degree of exposure of subchondral bone. A Pearson correlation was conducted between FTA and knee flexion angle to determine whether high a degree of FTA caused knee flexion restriction. A logistic regression analysis was also conducted to detect the locations and levels of cartilage degeneration causing knee flexion restriction. No correlation was found between FTA and flexion angle (r = -0.08). Flexion angle was not restricted with increasing FTA. Logistic regression analysis showed significant correlation between restricted knee ROM and levels of knee cartilage degeneration in the patella (odds ratio (OR) = 1.77; P = 0.01), the lateral femoral condyle (OR = 1.62; P = 0.03) and the posterior medial femoral condyle (OR = 1.80; P = 0.03). For clinical relevance, soft tissue release and osteophyte resection around the patella, lateral femoral condyle and posterior medial femoral condyle might be indicated to obtain a higher degree of knee flexion angle.

  12. Three-Dimensional Analysis of the Characteristics of the Femoral Canal Isthmus: An Anatomical Study

    Directory of Open Access Journals (Sweden)

    Xiu-yun Su

    2015-01-01

    Full Text Available Purpose. To establish a new approach for measuring and locating the femoral intramedullary canal isthmus in 3-dimensional (3D space. Methods. Based on the computed tomography data from 204 Chinese patients, 3D models of the whole femur and the corresponding femoral isthmus tube were reconstructed using Mimics software (Materialise, Haasrode, Belgium. The anatomical parameters of the femur and the isthmus, including the femur length and radius, and the isthmus diameter and height, were measured accordingly. Results. The mean ratio of the isthmus height versus the femoral height was 55 ± 4.8%. The mean diameter of the isthmus was 10.49 ± 1.52 mm. The femoral length, the isthmus diameter, and the isthmus tube length were significantly larger in the male group. Significant correlations were observed between the femoral length and the isthmus diameter (r=0.24, p<0.01 and between the femoral length and the isthmus height (r=0.6, p<0.01. Stepwise linear regression analyses demonstrated that the femoral length and radius were the most important factors influencing the location and dimension of the femoral canal isthmus. Conclusion. The current study developed a new approach for measuring the femoral canal and for optimization of customer-specific femoral implants.

  13. Femoral neck fractures: A prospective assessment of the pattern ...

    African Journals Online (AJOL)

    OBJECTIVE: To review the pattern of femoral neck fractures, complications and outcome following fixation with Austin-Moore endoprosthesis. METHOD: A two year prospective study in patients who had fracture of the femoral neck based on strict inclusion criteria. All the patients were treated by Austin-Moore ...

  14. Characterization of temperature-dependent optical material properties of polymer powders

    Energy Technology Data Exchange (ETDEWEB)

    Laumer, Tobias [Bayerisches Laserzentrum GmbH, 91052 Erlangen (Germany); SAOT Erlangen Graduate School in Advanced Optical Technologies, 91052 Erlangen (Germany); CRC Collaborative Research Center 814 - Additive Manufacturing, 91052 Erlangen (Germany); Stichel, Thomas; Bock, Thomas; Amend, Philipp [Bayerisches Laserzentrum GmbH, 91052 Erlangen (Germany); CRC Collaborative Research Center 814 - Additive Manufacturing, 91052 Erlangen (Germany); Schmidt, Michael [Bayerisches Laserzentrum GmbH, 91052 Erlangen (Germany); University of Erlangen-Nürnberg, Institute of Photonic Technologies, 91052 Erlangen (Germany); SAOT Erlangen Graduate School in Advanced Optical Technologies, 91052 Erlangen (Germany); CRC Collaborative Research Center 814 - Additive Manufacturing, 91052 Erlangen (Germany)

    2015-05-22

    In former works, the optical material properties of different polymer powders used for Laser Beam Melting (LBM) at room temperature have been analyzed. With a measurement setup using two integration spheres, it was shown that the optical material properties of polymer powders differ significantly due to multiple reflections within the powder compared to solid bodies of the same material. Additionally, the absorption behavior of the single particles shows an important influence on the overall optical material properties, especially the reflectance of the powder bed. Now the setup is modified to allow measurements at higher temperatures. Because crystalline areas of semi-crystalline thermoplastics are mainly responsible for the absorption of the laser radiation, the influence of the temperature increase on the overall optical material properties is analyzed. As material, conventional polyamide 12 and polypropylene as new polymer powder material, is used. By comparing results at room temperature and at higher temperatures towards the melting point, the temperature-dependent optical material properties and their influence on the beam-matter interaction during the process are discussed. It is shown that the phase transition during melting leads to significant changes of the optical material properties of the analyzed powders.

  15. 21 CFR 888.3400 - Hip joint femoral (hemi-hip) metallic resurfacing prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic resurfacing... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3400 Hip joint femoral (hemi-hip) metallic resurfacing prosthesis. (a) Identification. A hip joint femoral (hemi-hip...

  16. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femoral (hemi-knee) metallic uncemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint femoral (hemi-knee) metallic uncemented prosthesis. (a) Identification. A knee joint femoral (hemi-knee...

  17. Structural and functional studies of bioobjects prepared from femoral heads

    Energy Technology Data Exchange (ETDEWEB)

    Kirilova, I. A., E-mail: IKirilova@niito.ru; Podorozhnaya, V. T., E-mail: VPodorognaya@niito.ru [Research Institute of Traumatology and Orthopedics n.a. Ya.L. Tsivyan, 17, Frunze, Novosibirsk, 630091 (Russian Federation); Sharkeev, Yu. P., E-mail: sharkeev@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, 2/4, pr. Akademicheskii, Tomsk, 634021 (Russian Federation); National Research Tomsk Polytechnic University, 30, Lenin Avenue, Tomsk, 634050 (Russian Federation); Popova, K. S., E-mail: kseniya@ispms.tsc.ru; Uvarkin, P. V., E-mail: uvarkin@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, 2/4, pr. Akademicheskii, Tomsk, 634021 (Russian Federation)

    2015-11-17

    Results of examination of physicomechanical characteristics of samples of medial femoral head cuts are presented. The samples of medial femoral head cuts resected in 6 patients with coxarthrosis in primary endoprosthetic replacement of a coxofemoral joint have been tested for micro- and nanohardness. Young’s modulus and elemental composition of bone tissue have been investigated. To estimate the architectonics of cancellous tissue of the femoral head, adjacent cuts of the same patient have been analyzed. The porosity of bone tissue was estimated from macroscopic images obtained using macrophotography. The total porosity is calculated as the ratio of the total length of straight line segments overlapping pores to the total length of secants. A three-point bending test of the samples has shown that their strength changed from 0.187 to 1.650 MPa and their elasticity modulus changes from 1.69 to 8.15 MPa. The microhardness of the samples changes in the range 220–265 MPa and the average microhardness of medial femoral head cuts is 240 MPa. The elemental composition of medial femoral head cuts is represented by basic Ca, P, O, Na and Mg elements as well as by Sn, S, Fe, Cr, and C in microamounts. The atomic Ca to P ratio for bone tissue is 1.55. It is revealed that pores of the upper part of the femoral head have a more regular shape and in the lower part they are more elongated along the cut and occupy a larger volume. The lower part of the femoral head has a higher porosity (39 and 33%) than the upper part (34 and 30%). The total porosity of all samples does not exceed 37%.

  18. Management of Post-Traumatic Phlegmasia Cerulea Dolens via Right-to-Left Femoral Vein to Femoral Vein Bypass (Palma Procedure).

    Science.gov (United States)

    Dua, Anahita; Heller, Jennifer; Lee, Cheong

    2017-11-01

    Phlegmasia cerulea dolens (PCD) is a rare condition resulting from venous occlusion that impairs arterial flow. We report a rare case of post-traumatic PCD after ligation of the iliac vein with successful treatment by right-to-left femoral vein to femoral vein bypass using left great saphenous vein (Palma procedure). The clinical presentation, diagnostic process, and approach to management along with a literature review on the operative management of PCD are presented in this case report.

  19. Closed reduction, internal fixation with quadratus femoris muscle pedicle bone grafting in displaced femoral neck fracture

    Directory of Open Access Journals (Sweden)

    Chaudhuri Sibaji

    2008-01-01

    Full Text Available Background: Management of femoral neck fracture is still considered as an unsolved problem. It is more evident in displaced fractures where this fracture is considered as some sort of vascular insult to the head of the femur. We have used closed reduction, internal fixation and quadratus femoris muscle pedicle bone grafting in fresh displaced femoral neck fractures. Materials and Methods: From April 1996 to December 2004 we operated 73 consecutive patients of displaced femoral neck fracture in the age group of 24 to 81 years, mean age being 54.6 years. The patients were operated within one week of injury, the mean delay being 3.6 days. Closed reduction internal fixation along with quadratus femoris muscle pedicle bone grafting was done in all cases. They were followed up for an average period of 5.6 years (range 2-11 years. Results: Results were assessed according to modified Harris Hip Scoring system and found to be excellent in 53, good in 12, fair in six and poor in two patients. Bony union occurred in 68 cases, no patient developed avascular necrosis (AVN till date. Conclusion: For fresh displaced femoral neck fracture in physiologically active patients closed reduction, internal fixation and quadratus femoris muscle pedicle bone grafting is a suitable option to secure union and prevent development of AVN.

  20. Hip dislocation following the treatment of femoral neck fracture: Case report

    Directory of Open Access Journals (Sweden)

    Vukašinović Zoran

    2010-01-01

    Full Text Available Introduction. Femoral neck fractures are very rare in young patients and are frequently complicated by femoral head osteonecrosis and femoral neck nonunion. Case Outline. A 19-year-old girl with hip dislocation following the treatment of the femoral neck fracture is presented. The femoral neck fracture was initially treated by open reduction and three-screw fixation. After detecting the nonunion of femoral neck, valgus osteotomy was done. Secondary, iatrogenic, hip dislocation appeared. The patient had pains, and in clinical findings a shorter leg and limited range of motion in the hip - altogether 40 degrees. She was then successfully treated by open reduction, together with Chiari pelvic osteotomy and joint transfixation. Transfixation pin was removed three weeks following the operation. After that, the patient was put into the abduction device and physical therapy was started. The mentioned regimen lasted four months after the surgery, then the abduction device was removed and walking started. Full weight bearing was allowed eight months after surgery. Conclusion. As we have not found the literature data concerning the above mentioned problem, we solved it in the way that we usually do for the treatment of developmental dislocation of the hip in adolescence.

  1. Estimated carotid-femoral pulse wave velocity has similar predictive value as measured carotid-femoral pulse wave velocity

    DEFF Research Database (Denmark)

    Olsen, Michael; Greve, Sara; Blicher, Marie

    2016-01-01

    OBJECTIVE: Carotid-femoral pulse wave velocity (cfPWV) adds significantly to traditional cardiovascular (CV) risk prediction, but is not widely available. Therefore, it would be helpful if cfPWV could be replaced by an estimated carotid-femoral pulse wave velocity (ePWV) using age and mean blood...... pressure and previously published equations. The aim of this study was to investigate whether ePWV could predict CV events independently of traditional cardiovascular risk factors and/or cfPWV. DESIGN AND METHOD: cfPWV was measured and ePWV calculated in 2366 apparently healthy subjects from four age...

  2. Thermophysical properties of materials for water cooled reactors

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    The IAEA Co-ordinated Research Programme (CRP) to establish a thermophysical properties data base for light and heavy water reactor materials was organized within the framework of the IAEA`s International Working Group on Advanced Technologies for Water Cooled Reactors. The work within the CRP started in 1990. The objective of the CRP was to collect and systemaize a thermophysical properties data base for light and heavy water reactor materials under normal operating, transient and accident conditions. The important thermophysical properties include thermal conductivity, thermal diffusivity, specific heat capacity, enthalpy, thermal expansion and others. These properties as well as the oxidation of zirconium-based alloys, the thermophysical characteristics of high temperature concrete-core melt interaction and the mechanical properties of construction materials are presented in this report. It is hoped that this report will serve as a useful source of thermophysical properties data for water cooled reactor analyses. The properties data are maintained on the THERSYST system at the University of Stuttgart, Germany and are internationally available. Refs, figs, tabs.

  3. Thermophysical properties of materials for water cooled reactors

    International Nuclear Information System (INIS)

    1997-06-01

    The IAEA Co-ordinated Research Programme (CRP) to establish a thermophysical properties data base for light and heavy water reactor materials was organized within the framework of the IAEA's International Working Group on Advanced Technologies for Water Cooled Reactors. The work within the CRP started in 1990. The objective of the CRP was to collect and systemaize a thermophysical properties data base for light and heavy water reactor materials under normal operating, transient and accident conditions. The important thermophysical properties include thermal conductivity, thermal diffusivity, specific heat capacity, enthalpy, thermal expansion and others. These properties as well as the oxidation of zirconium-based alloys, the thermophysical characteristics of high temperature concrete-core melt interaction and the mechanical properties of construction materials are presented in this report. It is hoped that this report will serve as a useful source of thermophysical properties data for water cooled reactor analyses. The properties data are maintained on the THERSYST system at the University of Stuttgart, Germany and are internationally available. Refs, figs, tabs

  4. Size-Dependent Materials Properties Toward a Universal Equation

    Directory of Open Access Journals (Sweden)

    Guisbiers G

    2010-01-01

    Full Text Available Abstract Due to the lack of experimental values concerning some material properties at the nanoscale, it is interesting to evaluate this theoretically. Through a “top–down” approach, a universal equation is developed here which is particularly helpful when experiments are difficult to lead on a specific material property. It only requires the knowledge of the surface area to volume ratio of the nanomaterial, its size as well as the statistic (Fermi–Dirac or Bose–Einstein followed by the particles involved in the considered material property. Comparison between different existing theoretical models and the proposed equation is done.

  5. The treatment of nonisthmal femoral shaft nonunions with im nail exchange versus augmentation plating.

    Science.gov (United States)

    Park, Jin; Kim, Sul Gee; Yoon, Han Kook; Yang, Kyu Hyun

    2010-02-01

    The purpose of this study was to compare the results between exchange nailing (EN) and augmentation plating (AP) with a nail left in situ for nonisthmal femoral shaft nonunion after femoral nailing. : Retrospective data analysis, November 1996-March 2006. A level I trauma center. Eighteen patients with 18 nonisthmal femoral nonunions. Seven patients with 7 fractures treated for nonisthmal femoral shaft nonunions after femoral nailing with EN and 11 patients with 11 fractures treated for nonisthmal femoral shaft nonunions after nailing with AP combined with bone grafting. Union and complications. Five nonunions in the EN group failed to achieve union (72% failure rate), whereas all 11 pseudarthroses in the AP group obtained osseous union. Fisher exact test showed a higher nonunion rate of EN compared with AP for nonisthmal femoral shaft nonunion (odds ratio, 6.5; P = 0.002). AP with autogenous bone grafting may be a better option than EN for nonisthmal femoral nonunions.

  6. Femoral neck fractures after removal of hardware in healed trochanteric fractures.

    Science.gov (United States)

    Barquet, Antonio; Giannoudis, Peter V; Gelink, Andrés

    2017-12-01

    Hardware removal in healed trochanteric fractures (TF) in the absence of infection or significant mechanical complications is rarely indicated. However, in patients with persistent pain, prominent material and discomfort in the activities of daily living, the implant is eventually removed. Publications of ipsilateral femoral neck fracture after removal of implants from healed trochanteric fractures (FNFARIHTF) just because of pain or discomfort are rare. The purpose of this systematic review of the literature is to report on the eventual risk factors, the mechanisms, the clinical presentation, and frequency, and to pay special emphasis in their prevention. A comprehensive review of the literature was undertaken using the PRISMA guidelines with no language restriction. Case reports of FNFARIHTF and series of TF with cases of FNFARIHTF due to pain or discomfort published between inception of journals to December 2016 were eligible for inclusion. Relevant information was divided in two parts. Part I included the analysis of cases of FNFARIHTF, with the objective of establishing the eventual risk factors, mechanisms and pathoanatomy, clinical presentation and diagnosis, treatment and prevention. Part II analyzed series of TF which included cases of FNFARIHTF for assessing the incidence of femoral neck fractures in this condition. Overall 24 publications with 45 cases of FNFARIHTF met the inclusion criteria. We found that the only prevalent factors for FNFARIHTF were: 1) preexisisting systemic osteoporosis, as most patients were older and elder females, with lower bone mineral density and bone mass; 2) local osteoporosis as a result of preloading by the fixation device in the femoral neck, leading to stress protection, reducing the strain at the neck, and increasing bone loss and weakness; and 3) the removal of hardware from the femoral neck, with reduction of the failure strength of the neck. The femoral neck fractures were spontaneous, i.e. not related to trauma or

  7. Experimental and computational analysis of micromotions of an uncemented femoral knee implant using elastic and plastic bone material models

    NARCIS (Netherlands)

    Berahmani, Sanaz; Janssen, Dennis; Verdonschot, Nico

    2017-01-01

    It is essential to calculate micromotions at the bone-implant interface of an uncemented femoral total knee replacement (TKR) using a reliable computational model. In the current study, experimental measurements of micromotions were compared with predicted micromotions by Finite Element Analysis

  8. Current indications for open Kuntscher nailing of femoral shaft ...

    African Journals Online (AJOL)

    Current indications for open Kuntscher nailing of femoral shaft fractures. A S Bajwa FCS(SA)ORTH. E Schnaid FCS(SA)ORTH. M E B Sweet MD PhD(rned). University of Witwatersrand, Johannesburg, South Africa. Key Words: Kuntscher nail, intramedullary nail, femoral fracture. We retrospectively reviewed 32 patients with.

  9. Image features of herniation pit of the femoral neck

    International Nuclear Information System (INIS)

    Zhang Xuezhe; Li Guangming; Wang Cunli; Wang Guimin

    2008-01-01

    Objective: To evaluate imaging appearances of herniation pit of the femoral neck. Methods: We retrospectively analyzed the X-ray, CT and MRI findings of 9 patients with herniation pit of the femoral neck. All nine patients were male with the age ranging from 21 to 73 years. They had pain in the hip from two months to two years duration. Results: The bilateral hips were affected in six patients, the right hips in the other 3 patients. Of the nine patients, X-ray plain films (2 cases), CT scanning(6 cases), and MR scanning (5 cases ) were performed. The size of the lesions ranged from 0.5 cm x 0.6 cm to 1.0 cm x 1.5 cm, located in the anterosuperior portion of the femoral neck (n=7) or anteroinferior portion (n=2). X-ray plain films showed an osteolytic lesion surrounded by a sclerotic rim. CT scanning showed the lesion just below the cortex of the femoral neck surrounded by a rim of sclerosis or associated with a small cortical break in two patients. MR scanning showed low signal intensity in five patients on T 1 WI and high signal intensity surrounded by a rim of low signal intensity (n=3) or low signal intensity (n=2) on T 2 WI, and high signal intensity on fat suppression MR image. A small joint effusion was observed in two cases on T 2 WI. Conclusion: The CT and MRI findings of herniation pit of the femoral neck are characteristic, it is useful in defining the diagnosis of the herniation pit of the femoral neck. (authors)

  10. Osteonecrosis of femoral head: Treatment by core decompression and vascular pedicle grafting

    Directory of Open Access Journals (Sweden)

    Babhulkar Sudhir

    2009-01-01

    Full Text Available Background: Femoral head-preserving core decompression and bone grafting have shown excellent result in preventing collapse. The use of vascularized grafts have shown better clinical results. The vascular pedicle bone graft is an easy to perform operation and does not require special equipment. We analyzed and report a series of patients of osteonecrosis of femoral head treated by core decompression and vascular pedicle grafting of part of iliac crest based on deep circumflex iliac vessels. Materials and Methods: The article comprises of the retrospective study of 31 patients of osteonecrosis of femoral head in stage II and III treated with core decompression and vascular pedicle grafting by using part of iliac crest with deep circumflex iliac vessels from January 1990 to December 2005. The young patients with a mean age 32 years (18-52 years with a minimum follow-up of five years were included for analysis. Sixteen patients had osteonecrosis following alcohol abuse, 12 patients following corticosteroid consumption, 3 patients had idiopathic osteonecrosis. Nine patients were stage IIB, and 22 patients were stage IIIC according to ARCO′s system. The core decompression and vascular pedicle grafting was performed by anterior approach by using part of iliac crest with deep circumflex iliac vessels. Results: Digital subtraction arteriography performed in 9 patients at the end of 12 weeks showed the patency of deep circumflex artery in all cases, and bone scan performed in 6 other patients showed high uptake in the grafted area of the femoral head proving the efficacy of the operative procedure. Out of 31 patients, only one patient progressed to collapse and total joint replacement was advised. At the final follow up period of 5-8 years, Harris Hip Score improved mean ± SD of 28.2 ± 6.4 ( p < 0.05. Forty-eight percent of patients had an improvement in Harris Hip Score of more that 28 points. Conclusion: The core decompression and vascular pedicle

  11. Transtrochanteric rotational osteotomy for avascular necrosis of the femoral head after unstable slipped capital femoral epiphysis: 10-year clinical results.

    Science.gov (United States)

    Nakashima, Yasuharu; Yamamoto, Takuaki; Fukushi, Jun-Ichi; Motomura, Goro; Hamai, Satoshi; Kohno, Yusuke; Iwamoto, Yukihide

    2016-11-01

    Avascular necrosis of the femoral head (AVN) is the most serious complication after unstable slipped capital femoral epiphysis (SCFE), and is often unsalvageable. We report a minimum 10 years of clinical results for transtrochanteric rotational osteotomy of the femoral head (TRO) for AVN. This study included 7 patients (7 hips) with a mean age at surgery of 13.3 years, and the follow-up period was 15.8 years. All patients had prior treatment via closed reduction and pinning of the unstable SCFE, and showed severely collapsed femoral heads. The direction of rotation was anterior in 3 hips and posterior in 4. The Merle d'Aubigné-Postel score (MDPS) was used for clinical assessment, and joint degeneration was assessed with the Kellgren and Lawrence classification (KL-grade). The spherical intact area of the femoral head was moved to the weight-bearing portion, and subluxation was corrected via rotation combined with intentional varus positioning. The mean MDPS improved from 10.3 points to 15.6 points at 5 years, and it was maintained at 15.0 points by 10 years; 3 hips were excellent, 1 was good, 2 were fair, and 1 showed poor outcomes. No patient experienced re-collapse after TRO or required conversion to hip replacement or arthrodesis. After 10 years, degenerative changes became evident over time, and 2 hips progressed to KL-4 with a decreased MDPS. Although some joint degeneration is inevitable in the long-term, TRO is an effective salvage procedure for treating AVN after unstable SCFE. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  12. The Incidence of Atypical Femoral Fractures in Patients with Rheumatic Disease: Yamagata Prefectural Committee of Atypical Femoral Fractures (YamaCAFe) Study.

    Science.gov (United States)

    Takakubo, Yuya; Ohta, Daichi; Ishi, Masaji; Ito, Juji; Oki, Hiroharu; Naganuma, Yasushi; Uno, Tomohiro; Sasaki, Akiko; Akabane, Takeru; Dairaku, Katsuyuki; Goto, Shinichi; Goto, Yasuo; Kanauchi, Yumiko; Kobayashi, Shinji; Nakajima, Taku; Masuda, Keiji; Matsuda, Michiharu; Mura, Nariyuki; Takenouchi, Kenji; Tsuchida, Hiroyuki; Onuma, Yasushi; Shibuya, Junichirou; Seino, Mitsuyoshi; Yamaguchi, Osamu; Hiragami, Ken; Urayama, Yasuhiro; Furukawa, Takashi; Okuda, Shouta; Ogura, Ken; Nakamura, Takeshi; Sasaki, Kan; Konta, Tsuneo; Takagi, Michiaki

    2017-08-01

    Atypical femoral fractures (AFFs) have been reported to occur with minimal or spontaneous subtrochanteric and femoral shaft fractures with a characteristic transverse pattern, compared with typical femoral fractures in young patients with high-energy trauma. AFFs are related to long-term use of bisphosphonates (BPs), glucocorticoids and rheumatic diseases. We have estimated a blind analysis of AFFs in rheumatic patients receiving BPs and glucocorticoids ordinary over a long time in all Yamagata prefectural area through radiographic examination. The 123 AFFs including suspected cases over six years were collected and reviewed by two independent orthopedic surgeons. We found 86 patients with a total of 99 AFFs between 2009 and 2014 (1.43 cases/100,000 person/year). Of these 99 AFFs, 11 were in 8 rheumatic patients including three patients with bilateral AFFs. The incidence of AFFs in rheumatic patients had trend to increase from 2012. The mean age of all 8 patients was 54.9 years. All 8 patients received BPs and 7/8 received prednisolone (PSL). The mean dose of PSL was 14 mg/day. Compared to patients with unilateral AFFs, those with bilateral AFFs in rheumatic patients were on a higher dose of PSL (20 mg/day vs. 7 mg/day) and had less femoral neck-shaft angle (129° vs. 136°, p rheumatic patients showed a trend to increase from 2012 to 2014 in Yamagata prefecture. Careful management of AFFs is of particular importance in rheumatic patients who have taken high doses of PSL and have small femoral neck-shaft angle.

  13. Development of a method for measuring femoral torsion using real-time ultrasound

    International Nuclear Information System (INIS)

    Hafiz, Eliza; Hiller, Claire E; Nightingale, E Jean; Eisenhuth, John P; Refshauge, Kathryn M; Nicholson, Leslie L; Clarke, Jillian L; Grimaldi, Alison

    2014-01-01

    Excessive femoral torsion has been associated with various musculoskeletal and neurological problems. To explore this relationship, it is essential to be able to measure femoral torsion in the clinic accurately. Computerized tomography (CT) and magnetic resonance imaging (MRI) are thought to provide the most accurate measurements but CT involves significant radiation exposure and MRI is expensive. The aim of this study was to design a method for measuring femoral torsion in the clinic, and to determine the reliability of this method. Details of design process, including construction of a jig, the protocol developed and the reliability of the method are presented. The protocol developed used ultrasound to image a ridge on the greater trochanter, and a customized jig placed on the femoral condyles as reference points. An inclinometer attached to the customized jig allowed quantification of the degree of femoral torsion. Measurements taken with this protocol had excellent intra- and inter-rater reliability (ICC 2,1  = 0.98 and 0.97, respectively). This method of measuring femoral torsion also permitted measurement of femoral torsion with a high degree of accuracy. This method is applicable to the research setting and, with minor adjustments, will be applicable to the clinical setting. (paper)

  14. Free fibular strut graft in neglected femoral neck fractures in adult

    Directory of Open Access Journals (Sweden)

    Azam Md Quamar

    2009-01-01

    Full Text Available Background: Neglected femoral neck fracture in adults still poses a formidable challenge. Existing treatment options varies from osteotomy (with or without graft to osteosynthesis using various implants and grafting techniques (muscle pedicle, vascularized, and nonvascularized fibula. The aim of this study was to assess outcome of nonvascularized fibular strut graft and cancellous screw fixation in neglected femoral neck fractures in the younger age group. Materials and Methods: Medical records of 32 patients of neglected femoral neck fracture, in the age group of 22-45 years (mean 37.8 years, operated between May 1994 to December 2001, were retrospectively reviewed. After the application of inclusion and exclusion criteria, 28 patients having three years minimum follow-up (mean 4.6 years were included. Delay between injury and operation varied from four weeks to 42 weeks (mean 16.4 weeks. Closed reduction was achieved in 17 patients; open reduction through Watson-Jones anterolateral approach was performed in the remaining 15 patients in whom closed reduction failed. The fracture was transfixed with three parallel guide wires. Appropriate sized cannulated lag screw (7 mm was then inserted in two of the wires. Selection of the third guide wire for fibula depended on the space available in both anteroposterior and lateral view. Results: Satisfactory bony union was obtained in 25 patients, of whom in four cases, the union occurred in 10-20° (mean 15° of varus. Nonunion occurred in three patients (9.37%, and aseptic necrosis occurred in another six patients (18.75%. Of the 25 patients where union was achieved, five patients showed excellent results; 14 good and six had poor functional result, as evaluated using modified Anglen criteria. Conclusion: Nonvascularized fibular strut graft along with cancellous screws provides a dependable and technically less-demanding alternative procedure for neglected femoral neck fractures in young adults. Fibula

  15. Evaluation of femoral head viability via bone scintigraphy in the postoperative pediatric patient

    International Nuclear Information System (INIS)

    Parikh, Ashishkumar K.; Washington, Eleby R.; Spottswood, Stephanie E.; Bobbey, Adam J.

    2018-01-01

    Evaluating postoperative patients with hardware is challenging following surgical intervention for hip maladies such as femoral neck fractures and slipped capital femoral epiphysis (SCFE). These children are at increased risk of developing avascular necrosis, and imaging may be requested to confirm or exclude this diagnosis. Children with Legg-Calve-Perthes disease can be monitored for restoration of blood flow to the capital femoral epiphysis to guide management and help with prognosis. Although MRI is sensitive for detecting early avascular necrosis, the presence of hardware degrades image quality. This report examines the utility of bone scans for evaluating femoral head perfusion in children who have undergone surgery for femoral neck fractures, SCFE or Legg-Calve-Perthes disease. A retrospective review of 20 patients (22 scans) after fixation for femoral neck fracture, SCFE or Legg-Calve-Perthes disease from 2012 to 2015 was performed. The bone scan findings were correlated with the intraoperative findings or clinical follow-up. Twenty-one of the 22 (95%) bone scans in 19 of the 20 (95%) patients demonstrated findings consistent with clinical outcomes and/or the intraoperative appearance of the femoral head. Four of 20 patients (20%) had bone scan features of avascular necrosis, defined as ''absent'' or ''moderately diminished'' femoral head activity, which were confirmed intraoperatively and resulted in poor outcomes. Radionuclide imaging of hips in the postoperative setting is a valuable modality for assessing the risk of avascular necrosis, a complication of femoral neck fractures and SCFE and for evaluating the restoration of flow to the capital femoral epiphyses of children with Legg-Calve-Perthes disease. (orig.)

  16. Symmetric visualization of the femoral heads in reticuloendothelial bone marrow scanning in adults

    Energy Technology Data Exchange (ETDEWEB)

    Munz, D L; Hoer, G

    1983-03-01

    Two hundred and twenty seven consecutive patients of either sex aged 15-84 suffering from various benign and malignant disorders were studied by sup(99m)Tc-HSA-MM reticuloendothelial bone marrow scintigraphy. In all patients, symmetric findings concerning visualization or nonvisualization of the femoral heads could be seen. Femoral heads were clearly visualized in 48%, nonvisualized in 43%, and equivocally visualized in 9%. In patients with clearly visualized femoral heads, the bone marrow showed peripheral extension in 81%, whereas in patients with nonvisualized femoral heads, bone marrow extension was observed in only 42%. There was a correlation between the degree of bone marrow extension and the ability to visualize femoral heads. There was no obvious difference between males and females, nor patients with various diseases or treatments, amongst nor between different age groups. Two hypotheses are suggested to explain the correspondence between presence of bone marrow tissue in the femoral heads and peripheral extension of the bone marrow organ. Nonvisualization of the femoral heads alone is insufficient to establish the diagnosis of avascular necrosis.

  17. IMAP: Interferometry for Material Property Measurement in MEMS

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, B.D.; Miller, S.L.; de Boer, M.P.

    1999-03-10

    An interferometric technique has been developed for non-destructive, high-confidence, in-situ determination of material properties in MEMS. By using interferometry to measure the full deflection curves of beams pulled toward the substrate under electrostatic loads, the actual behavior of the beams has been modeled. No other method for determining material properties allows such detailed knowledge of device behavior to be gathered. Values for material properties and non-idealities (such as support post compliance) have then been extracted which minimize the error between the measured and modeled deflections. High accuracy and resolution have been demonstrated, allowing the measurements to be used to enhance process control.

  18. STUDY OF ULTRASOUND-GUIDED CONTINUOUS FEMORAL NERVE BLOCKADE WITH EPIDURAL ANALGESIA FOR PAIN RELIEF AFTER TOTAL KNEE REPLACEMENT

    Directory of Open Access Journals (Sweden)

    Srinivas Rapolu

    2016-11-01

    Full Text Available BACKGROUND Total knee replacement causes moderate-to-severe pain requiring effective analgesia. With use of ultrasound guidance, we may prove a more suitable approach compared with the epidural technique. Aim of this study is the comparison between Continuous Epidural Analgesia (CEA and Continuous Femoral Block (CFB techniques in Total Knee Replacement surgeries. MATERIALS AND METHODS This study was conducted on 60 adult male and female patients undergoing total knee replacement surgery for a period of 2 years. Patients were divided into 2 groups. Group - 1: Continuous epidural analgesia patients, Group - 2: Continuous femoral blockage patients. All patients were assessed clinically preoperatively and investigated to rule out any systemic disease. RESULTS The mean age of patient in Group - 1 was 66.54 ± 4.98 and in Group - 2 was 66.98 ± 5.02 years. P value was > 0.05, which was not significant. No significant differences in gender is observed between the groups. VAS scores were significantly high (P < 0.05 in the femoral group at 6 h, after which there was a declining trend and scores were essentially similar from 24 h. The use of rescue analgesic was also higher in the femoral group. Analysis of side-effects showed that all the five common sideeffects were twice as common in the epidural group than in the femoral study group. Only one patient in the femoral group had urinary retention when compared with four in the epidural group. The differences were not statistically significant. Muscle power at 48 h, time getting out of the bed and time stay in hospital (days are significant in comparison in 2 groups, range of movement is insignificant in groups. Patient satisfaction score was measured on a scale of 1 - 10. Patients in the Femoral group were slightly more satisfied with a mean ± SD score of 8.1 ± 1.2 when compared with the epidural group 7.3 ± 1.01. CONCLUSION Continuous femoral blockade using US guidance provides equivalent analgesia

  19. A biomechanical comparison of proximal femoral nails and locking proximal anatomic femoral plates in femoral fracture fixation A study on synthetic bones

    Directory of Open Access Journals (Sweden)

    Korhan Ozkan

    2015-01-01

    Conclusion: The proximal femoral intramedullary nail provides more stability and allows for earlier weight bearing than the locking plate when used for the treatment of unstable intertrochanteric fractures of the femur. Clinicians should be cautious for early weight bearing with locking plate for unstable intertrochanteric femur fractures.

  20. Hybrid micro/nano-topography of a TiO2 nanotube-coated commercial zirconia femoral knee implant promotes bone cell adhesion in vitro.

    Science.gov (United States)

    Frandsen, Christine J; Noh, Kunbae; Brammer, Karla S; Johnston, Gary; Jin, Sungho

    2013-07-01

    Various approaches have been studied to engineer the implant surface to enhance bone in-growth properties, particularly using micro- and nano-topography. In this study, the behavior of osteoblast (bone) cells was analyzed in response to a titanium oxide (TiO2) nanotube-coated commercial zirconia femoral knee implant consisting of a combined surface structure of a micro-roughened surface with the nanotube coating. The osteoblast cells demonstrated high degrees of adhesion and integration into the surface of the nanotube-coated implant material, indicating preferential cell behavior on this surface when compared to the bare implant. The results of this brief study provide sufficient evidence to encourage future studies. The development of such hierarchical micro- and nano-topographical features, as demonstrated in this work, can provide insightful designs for advanced bone-inducing material coatings on ceramic orthopedic implant surfaces. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Dielectric Characteristics of Microstructural Changes and Property Evolution in Engineered Materials

    Science.gov (United States)

    Clifford, Jallisa Janet

    Heterogeneous materials are increasingly used in a wide range of applications such as aerospace, civil infrastructure, fuel cells and many others. The ability to take properties from two or more materials to create a material with properties engineered to needs is always very attractive. Hence heterogeneous materials are evolving into more complex formulations in multiple disciplines. Design of microstructure at multiple scales control the global functional properties of these materials and their structures. However, local microstructural changes do not directly cause a proportional change to the global properties (such as strength and stiffness). Instead, local changes follow an evolution process including significant interactions. Therefore, in order to understand property evolution of engineered materials, microstructural changes need to be effectively captured. Characterizing these changes and representing them by material variables will enable us to further improve our material level understanding. In this work, we will demonstrate how microstructural features of heterogeneous materials can be described quantitatively using broadband dielectric spectroscopy (BbDS). The frequency dependent dielectric properties can capture the change in material microstructure and represent these changes in terms of material variables, such as complex permittivity. These changes in terms of material properties can then be linked to a number of different conditions, such as increasing damage due to impact or fatigue. Two different broadband dielectric spectroscopy scanning modes are presented: bulk measurements and continuous scanning to measure dielectric property change as a function of position across the specimen. In this study, we will focus on ceramic materials and fiber reinforced polymer matrix composites as test bed material systems. In the first part of the thesis, we will present how different micro-structural design of porous ceramic materials can be captured

  2. Fourier transform infrared imaging of femoral neck bone: reduced heterogeneity of mineral-to-matrix and carbonate-to-phosphate and more variable crystallinity in treatment-naive fracture cases compared with fracture-free controls.

    Science.gov (United States)

    Gourion-Arsiquaud, Samuel; Lukashova, Lyudmilla; Power, Jon; Loveridge, Nigel; Reeve, Jonathan; Boskey, Adele L

    2013-01-01

    After the age of 60 years, hip fracture risk strongly increases, but only a fifth of this increase is attributable to reduced bone mineral density (BMD, measured clinically). Changes in bone quality, specifically bone composition as measured by Fourier transform infrared spectroscopic imaging (FTIRI), also contribute to fracture risk. Here, FTIRI was applied to study the femoral neck and provide spatially derived information on its mineral and matrix properties in age-matched fractured and nonfractured bones. Whole femoral neck cross sections, divided into quadrants along the neck's axis, from 10 women with hip fracture and 10 cadaveric controls were studied using FTIRI and micro-computed tomography. Although 3-dimensional micro-CT bone mineral densities were similar, the mineral-to-matrix ratio was reduced in the cases of hip fracture, confirming previous reports. New findings were that the FTIRI microscopic variation (heterogeneity) of the mineral-to-matrix ratio was substantially reduced in the fracture group as was the heterogeneity of the carbonate-to-phosphate ratio. Conversely, the heterogeneity of crystallinity was increased. Increased variation of crystallinity was statistically associated with reduced variation of the carbonate-to-phosphate ratio. Anatomical variation in these properties between the different femoral neck quadrants was reduced in the fracture group compared with controls. Although our treatment-naive patients had reduced rather than increased bending resistance, these changes in heterogeneity associated with hip fracture are in another way comparable to the effects of experimental bisphosphonate therapy, which decreases heterogeneity and other indicators of bone's toughness as a material. Copyright © 2013 American Society for Bone and Mineral Research.

  3. Femoral bifurcation with ipsilateral tibia hemimelia: Early outcome of ...

    African Journals Online (AJOL)

    Hereby, we present a case report of a 2-year-old boy who first presented in our orthopedic clinic as a 12-day-old neonate, with a grossly deformed right lower limb from a combination of complete tibia hemimelia and ipsilateral femoral bifurcation. Excision of femoral exostosis, knee disarticulation and prosthetic fitting gives ...

  4. Modification of Textile Materials' Surface Properties Using Chemical Softener

    Directory of Open Access Journals (Sweden)

    Jurgita KOŽENIAUSKIENĖ

    2011-03-01

    Full Text Available In the present study the effect of technological treatment involving the processes of washing or washing and softening with chemical cationic softener "Surcase" produced in Great Britain on the surface properties of cellulosic textile materials manufactured from cotton, bamboo and viscose spun yarns was investigated. The changes in textile materials surface properties were evaluated using KTU-Griff-Tester device and FEI Quanta 200 FEG scanning electron microscope (SEM. It was observed that the worst hand properties and the higher surface roughness are observed of cotton materials if compared with those of bamboo and viscose materials. Also, it was shown that depending on the material structure the handle parameters of knitted materials are the better than the ones of woven fabrics.http://dx.doi.org/10.5755/j01.ms.17.1.249

  5. Bone scintigraphy in idiopathic aseptic femoral head necrosis (IAFHN)

    Energy Technology Data Exchange (ETDEWEB)

    Dodig, D; Ugarkovic, B; Orlic, D

    1983-01-01

    Idiopathic aseptic femoral head necrosis (IAFHN) is a disease of unknown aetiology most commonly affecting adults, producing functional impairment of the hip joint and immobility. Characteristic macroscopic, microscopic and radiologic features include: (1) changes in joint cartilage, (2) subchondral necrotic area, (3) changes in fibrous tissue, and (4) osteosclerosis and vascular proliferation. The diagnosis is based on clinical and X-ray examinations. More recently scintigraphy has been used in diagnosing IAFHN. It is a very sensitive, but non-specific method. Nineteen patients aged 25-57 years were included in our study. Scintigrams were divided in four groups: (1) normal, (2) uniformly increased activity in the femoral head, (3) non-uniformly increased activity in the femoral head, and (4) a photon deficient area in the femoral head. A comparison of scintigraphy and radiological examination suggests that a photon deficient area corresponds with stage III of radiological classification, non-uniformly increased activity with stage II, and uniformly increased activity with stage I. These results indicate that scintigraphy can be used for staging of disease.

  6. [SURGICAL HIP DISLOCATION APPROACH FOR TREATMENT OF FEMORAL HEAD FRACTURE].

    Science.gov (United States)

    Tang, Yanfeng; Liu, Youwen; Zhu, Yingjie; Li, Jianming; Li, Wuyin; Li, Qiyi; Jia, Yudong

    2015-11-01

    To discuss the value of surgical hip dislocation approach in the treatment of femoral head fracture. A retrospectively analysis was made on the clinical data of 15 patients with femoral head fractures treated through surgical hip dislocation approach between January 2010 and February 2013. There were 11 men and 4 women with an average age of 30.8 years (range, 15-63 years). The causes included traffic accident injury in 9 cases, falling injury from height in 5 cases, and sports injury in 1 case. According to Pipkin typing, 2 cases were rated as type I, 7 cases as type II, 1 case as type III, and 5 cases as type IV. The interval of injury and operation was 2-10 days (mean, 4.1 days). Reduction was performed in 10 patients within 6 hours after injury, and then bone traction was given for 4-6 weeks except 5 patients who received reduction in the other hospital. Primary healing of incision was obtained in all patients after surgery without complications of dislocation and lower limbs deep venous thrombosis. The mean follow-up time was 29.9 months (range, 25-36 months). During follow-up, there was no infection, breakage of internal fixation, or nonunion of femoral greater trochanter fracture. In 3 patients having necrosis of the femoral head, 2 had no obvious symptoms [staging as IIa and IIb respectively according to Association Research Circulation Osseous (ARCO) staging system], and 1 (stage IIIb) had nonunion of the femoral neck fracture, who underwent total hip arthroplasty (THA). In 4 patients having myositis ossificans (2 cases of grade I, 1 case of grade II, and 1 case of grade III based on Brooker grading), no treatment was given in 3 cases and the focus was removed during THA in 1 case. According to the Thompson-Epstein scale at last follow-up, the results were excellent in 9 cases, good in 3 cases, fair in 1 case, and poor in 2 cases, and the excellent and good rate was 80%. Surgical hip dislocation approach can not only protect the residual vessels of the

  7. Multiple bony lesions other than femoral heads on 99mTc-MDP bone scan in patients with avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Choi, Yun Young; Yang, Seoung Oh; Moon, Dae Hyuk; Ryu, Jin Sook; Weon, Young Cheol; Shin, Myung Jin; Lee, Soo Ho; Lee, Hee Kyung; Chun, Hae Kyung

    1997-01-01

    To evaluate the clinical significance of the multiple increased uptake lesions other than in femoral heads as seen on whole body bone scan in patients with avascular necrosis of femoral heads. One hundred and seventy three patients with clinical diagnosis of avascular necrosis of the emoral head underwent a bone scan using Tc-99m MDP. Increased uptake lesions other than in femoral heads were evaluated, including frequency and common sites of in volvement, and correlated with clinical information and plain radiographic findings. Two hundred patients without AVN, who had undergone a bone scan, were included as a control group. Increased uptake lesions in extrafemoral head locations were found in 36 of 173 patients(20.8%;the location of 79 lesions was other than the femoral head, This result is statistically different from patients without avascular necrosis of femoral head(p<0.0001). The most common site of involvement was the knee joint area(62.5%). Other lesions were located in the mid-shafts of the long bones of the lower extremities, calcaneus, proximal humerus, etc., in order of decreasing frequency. Plain radiographs of 17 lesions were nonspecific, except for three lesions showing definite changes associated with avascular necrosis. The risk factors included alcoholism, the prolonged use of steroids, renal transplantation, herbal medication and working as a working as deep-sea diver. Most patients did not complain of pain, except for two with irreversible osteonecrotic changes as seen on plain radiograph. in patients with avascular necrosis of the femur, increased uptake lesions other than in the femoral head as seen on bone scan, may represent the early stage of osteonecrosis, which shows a characteristic appearance on bone scan. In order to aveid possible misdiagnoses of multiple extrafemoral lesions as bony metastasis or traumatic lesions, in patients with avascular necrosis of the femur these should be carefully evaluated

  8. 'Femoral head necrosis' in metabolic and hormonal osteopathies

    Energy Technology Data Exchange (ETDEWEB)

    Heuck, F.H.W.; Treugut, H.

    1984-07-01

    The pathogenesis of bone necrosis is discussed with special attention and with respect to metabolic, hormonal, and vascular factors. The influence of statics and dynamics of the hip joint bones for the development of aseptic necrosis are discussed. 45 patients with ''idiopathic femoral head necroses'' were observed, including 6 cases of renal osteopathy following renal transplantation and immune suppression therapy, 14 cases of long term corticoid therapy, and 11 cases of liver diseases of different genesis. The femoral head necrosis understood as complication of an osteopathy. In our patients there were 31 males and 14 females - which means higher involvement of males. Plain radiological findings and CT-findings of changes of the femoral heat structure in different stages of the disease are described. Early diagnosis of metabolic and hormonal osteopathies is demanded for a joint keeping therapy of the beginning femoral head necrosis. 90 refs.

  9. COMPARATIVE STUDY OF KUNTSCHER’S NAIL VS. INTERLOCKING NAILING FOR FEMORAL ISTHMUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Rajeev Kumar Roy

    2017-05-01

    Full Text Available BACKGROUND Interlocking intramedullary nailing is suitable for comminuted femoral isthmus fractures, but for non-comminuted fractures its benefit over unlocked nailing is debatable. This study was undertaken to compare outcomes of interlocking nailing versus k-nail in such fractures. MATERIALS AND METHODS 40 cases of noncomminuted femoral isthmus fractures treated with interlocking nailing and K-nail from April 1, 2015, to December 1, 2016, were reviewed. Radiological and clinical union rates, bony alignment, complication and knee function were investigated. RESULTS There was no statistical significant difference with regard to union rate, implant failure, infection and fracture alignment in both study groups. Open fixation with K-nail is technically less demanding and requires less operating time; additionally, there is no exposure to radiation and cost of the implant is cheaper. CONCLUSION We therefore conclude that unlocked nailing is still useful for the management of noncomminuted isthmus fractures of the femur.

  10. Anisotropic local physical properties of human dental enamel in comparison to properties of some common dental filling materials.

    Science.gov (United States)

    Raue, Lars; Hartmann, Christiane D; Rödiger, Matthias; Bürgers, Ralf; Gersdorff, Nikolaus

    2014-11-01

    A major aspect in evaluating the quality of dental materials is their physical properties. Their properties should be a best fit of the ones of dental hard tissues. Manufacturers give data sheets for each material. The properties listed are characterized by a specific value. This assumes (but does not prove) that there is no direction dependence of the properties. However, dental enamel has direction-dependent properties which additionally vary with location in the tooth. The aim of this paper is to show the local direction dependence of physical properties like the elastic modulus or the thermal expansion in dental hard tissues. With this knowledge the 'perfect filling/dental material' could be characterized. Enamel sections of ∼400-500 μm thickness have been cut with a diamond saw from labial/buccal to palatal/lingual (canine, premolar and molar) and parallel to labial (incisor). Crystallite arrangements have been measured in over 400 data points on all types of teeth with x-ray scattering techniques, known from materials science. X-ray scattering measurements show impressively that dental enamel has a strong direction dependence of its physical properties which also varies with location within the tooth. Dental materials possess only little or no property direction dependence. Therefore, a mismatch was found between enamel and dental materials properties. Since dental materials should possess equal (direction depending) properties, worthwhile properties could be characterized by transferring the directional properties of enamel into a property 'wish list' which future dental materials should fulfil. Hereby the 'perfect dental material' can be characterized.

  11. Leg lengthening and femoral-offset reduction after total hip arthroplasty: where is the problem - stem or cup positioning?

    Science.gov (United States)

    Al-Amiry, Bariq; Mahmood, Sarwar; Krupic, Ferid; Sayed-Noor, Arkan

    2017-09-01

    Background Restoration of femoral offset (FO) and leg length is an important goal in total hip arthroplasty (THA) as it improves functional outcome. Purpose To analyze whether the problem of postoperative leg lengthening and FO reduction is related to the femoral stem or acetabular cup positioning or both. Material and Methods Between September 2010 and April 2013, 172 patients with unilateral primary osteoarthritis treated with THA were included. Postoperative leg-length discrepancy (LLD) and global FO (summation of cup and FO) were measured by two observers using a standardized protocol for evaluation of antero-posterior plain hip radiographs. Patients with postoperative leg lengthening ≥10 mm (n = 41) or with reduced global FO >5 mm (n = 58) were further studied by comparing the stem and cup length of the operated side with the contralateral side in the lengthening group, and by comparing the stem and cup offset of the operated side with the contralateral side in the FO reduction group. We evaluated also the inter-observer and intra-observer reliability of the radiological measurements. Results Both observers found that leg lengthening was related to the stem positioning while FO reduction was related to the positioning of both the femoral stem and acetabular cup. Both inter-observer reliability and intra-observer reproducibility were moderate to excellent (intra-class correlation co-efficient, ICC ≥0.69). Conclusion Post THA leg lengthening was mainly caused by improper femoral stem positioning while global FO reduction resulted from improper positioning of both the femoral stem and the acetabular cup.

  12. Femoral intercondylar notch shape and dimensions in ACL-injured patients

    NARCIS (Netherlands)

    van Eck, Carola F.; Martins, Cesar A. Q.; Vyas, Shail M.; Celentano, Umberto; van Dijk, C. Niek; Fu, Freddie H.

    2010-01-01

    The femoral intercondylar notch has been an anatomic site of interest as it houses the anterior cruciate ligament (ACL). The objective of this study was to arthroscopically evaluate the femoral notch in patients with known ACL injury. This evaluation included establishing a classification for notch

  13. Modular femoral component for conversion of previous hip surgery in total hip arthroplasty.

    Science.gov (United States)

    Goldstein, Wayne M; Branson, Jill J

    2005-09-01

    The conversion of previous hip surgery to total hip arthroplasty creates a durable construct that is anatomically accurate. Most femoral components with either cemented or cementless design have a fixed tapered proximal shape. The proximal femoral anatomy is changed due to previous hip surgery for fixation of an intertrochanteric hip fracture, proximal femoral osteotomy, or a fibular allograft for avascular necrosis. The modular S-ROM (DePuy Orthopaedics Inc., Warsaw, Ind) hip stem accommodates these issues and independently prepares the proximal and distal portion of the femur. In preparation and implantation, the S-ROM hip stem creates less hoop stresses on potentially fragile stress risers from screws and thin bone. The S-ROM hip stem also prepares a previously distorted anatomy by milling through cortical bone that can occlude the femoral medullar canals and recreate proper femoral anteversion and reduces the risk of intraoperative or postoperative periprosthetic fracture due to the flexible titanium-slotted stem. The S-ROM femoral stem is recommended for challenging total hip reconstructions.

  14. Interactions between bio-tribocorrosion phenomena and cellular response of titanium-based femoral stems

    OpenAIRE

    Runa, Maria João Carvalho

    2016-01-01

    PhD thesis in Biomedical Engineering In orthopedics, the loosening/failure of the femoral stem of hip implants is a major concern. In uncemented Ti-based implants, the tribochemical reactions occurring at the implant/bone interface due to micromotion are known to contribute to these failures. However, the bio-tribocorrosion behavior of metallic materials and related mechanisms, induced by relative movements in a biological environment, is a complex process, largely unknown at p...

  15. Radioautographic study of two target organs (epididymis and femoral glands) after injection of 3H testosterone in a non-mammalian vertebrate, the viviparous Lizard

    International Nuclear Information System (INIS)

    Dufaure, J.-P.; Chambon, Monique.

    1978-01-01

    After 3 H testosterone injection into castrated males of the Lizard Lacerta vivipara, the radioactive compound is detected by radioautography of epididymis, femoral glands, gut and liver. Between 1 hr. 30 min. to 12 hrs. of retention the 3 H material concentrates progressively into nuclei of the glandular cells of epididymis and femoral organs although no particular concentration occurs in gut and liver cells. This submammalian model is consistent with those previously described for mammals [fr

  16. Pigmented Villonodular Synovitis Causing Osteonecrosis of the Femoral Head: A Case Report

    Directory of Open Access Journals (Sweden)

    Tomohiro Mimura

    2013-01-01

    Full Text Available We report a case of a 27-year-old man with pigmented villonodular synovitis of the hip joint with coincident osteonecrosis of the femoral head. According to our review of the English-language literature, no detailed report of osteonecrosis of the femoral head complicated with pigmented villonodular synovitis has been published. Preoperative X-ray images showed joint narrowing and severe multiple bone erosions at the acetabulum and femoral neck. Magnetic resonance imaging revealed a low-intensity band attributable to osteonecrosis of the femoral head and massive diffuse pigmented villonodular synovitis lesions. Comparison of a three-dimensional computed tomographic image of this patient with an angiographic image of a normal individual demonstrated proximity of the pigmented villonodular synovitis-induced bone erosions to the medial and lateral femoral circumflex arteries and retinacular arteries, suggesting likely the compromise of the latter by the former. We propose that the massive pigmented villonodular synovitis may have contributed to the pathogenesis of osteonecrosis of the femoral head in this patient. We performed open synovectomy and total hip arthroplasty. No operative complications occurred, and no recurrence of the pigmented villonodular synovitis was detected for 3 years after the operation.

  17. Microstructures and mechanical properties of aging materials

    International Nuclear Information System (INIS)

    Liaw, P.K.; Viswanathan, R.; Murty, K.L.; Simonen, E.P.; Frear, D.

    1993-01-01

    This book contains a collection of papers presented at the symposium on ''Microstructures and Mechanical Properties of Aging Materials,'' that was held in Chicago, IL. November 2-5, 1992 in conjunction with the Fall Meeting of The Minerals, Metals and Materials Society (TMS). The subjects of interest in the symposium included: (1) mechanisms of microstructural degradation, (2) effects of microstructural degradation on mechanical behavior, (3) development of life prediction methodology for in-service structural and electronic components, (4) experimental techniques to monitor degradation of microstructures and mechanical properties, and (5) effects of environment on microstructural degradation and mechanical properties. Individual papers have been processed separately for inclusion in the appropriate data bases

  18. Three-dimensional measurement of femoral neck anteversion and neck shaft angle.

    Science.gov (United States)

    Sangeux, Morgan; Pascoe, Jessica; Graham, H Kerr; Ramanauskas, Fiona; Cain, Tim

    2015-01-01

    We present a three-dimensional measurement technique for femoral neck anteversion and neck shaft angles which do not require alignment of the femoral and scanner axes. Two assessors performed the measurements on 11 patients (22 femurs). Repeatability between assessors was 2.7 degrees for femoral neck anteversion and 4.8 degrees for neck shaft angle. Measurements compared with an alternative single slice method were different by 2 degrees (3 degrees) in average. The method was repeatable and appropriate for clinical practice.

  19. Histopathology of femoral head donations: a retrospective review of 6161 cases.

    Science.gov (United States)

    Mackie, Katherine E; Zhou, Ziqiang; Robbins, Peter; Bulsara, Max; Zheng, Ming H

    2011-08-17

    Although total hip arthroplasty is one of the most common orthopaedic surgical procedures, it remains unclear whether histopathological examination of the excised femoral head adds to the quality of patient care. We propose that assessment of femoral heads resected during total hip arthroplasty and donated for allograft use may provide a profile of femoral head pathology that benefits total hip arthroplasty patients and bone donors. We retrospectively analyzed the histological findings reported for 6161 femoral heads donated for allograft use between 1993 and 2006. Specimens obtained during total hip arthroplasty and specimens donated at death were reviewed. Follow-up investigations that resulted from abnormal histopathological findings were also reviewed. The Western Australian Cancer Registry was used to determine whether patients with a suspected neoplasm were subsequently diagnosed with such a disease. A retrospective review of the histopathological findings was conducted to evaluate and reclassify all previous observations of abnormalities. One hundred and five femoral heads demonstrated abnormal or reactive histopathological features not reported prior to surgery and were rejected for allograft use. A reactive lymphocytic infiltrate, most likely due to osteoarthritis, was the most commonly identified feature (forty-five cases). Other features observed in twenty-seven cases were also most likely due to the presence of severe osteoarthritis. Ten femoral heads demonstrated plasmacytosis, which may have been related to osteoarthritis. Two patients were diagnosed with Paget's disease, and two, with rheumatoid arthritis. Nineteen patients had a suspected neoplasm. Of these nineteen, eight cases of non-Hodgkin's lymphoma or chronic lymphocytic leukemia and one case of myelodysplastic syndrome were confirmed on further investigation. One subsequently confirmed malignancy was detected per 770 femoral heads examined. Our findings indicate that, even with a detailed

  20. Data base on structural materials aging properties

    International Nuclear Information System (INIS)

    Oland, C.B.

    1992-01-01

    The US Nuclear Regulatory Commission has initiated a Structural Aging Program at the Oak Ridge National Laboratory to identify potential structural safety issues related to continued service of nuclear power plants and to establish criteria for evaluating and resolving these issues. One of the tasks in this program focuses on the establishment of a Structural Materials Information Center where long-term and environment-dependent properties of concretes and other structural materials are being collected and assembled into a data base. These properties will be used to evaluate the current condition of critical structural components in nuclear power plants and to estimate the future performance of these materials during the continued service period

  1. Delayed appearance of hypaesthesia and paralysis after femoral nerve block

    Directory of Open Access Journals (Sweden)

    Stefan Landgraeber

    2012-03-01

    Full Text Available We report on a female patient who underwent an arthroscopy of the right knee and was given a continuous femoral nerve block catheter. The postoperative course was initially unremarkable, but when postoperative mobilisation was commenced, 18 hours after removal of the catheter, the patient noticed paralysis and hypaesthesia. Examination confirmed the diagnosis of femoral nerve dysfunction. Colour duplex sonography of the femoral artery and computed tomography of the lumbar spine and pelvis yielded no pathological findings. Overnight the neurological deficits decreased without therapy and were finally no longer detectable. We speculate that during the administration of the local anaesthetic a depot formed, localised in the medial femoral intermuscular septa, which was leaked after first mobilisation. To our knowledge no similar case has been published up to now. We conclude that patients who are treated with a nerve block should be informed and physician should be aware that delayed neurological deficits are possible.

  2. Delayed appearance of hypaesthesia and paralysis after femoral nerve block

    Science.gov (United States)

    Landgraeber, Stefan; Albrecht, Thomas; Reischuck, Ulrich; von Knoch, Marius

    2012-01-01

    We report on a female patient who underwent an arthroscopy of the right knee and was given a continuous femoral nerve block catheter. The postoperative course was initially unremarkable, but when postoperative mobilisation was commenced, 18 hours after removal of the catheter, the patient noticed paralysis and hypaesthesia. Examination confirmed the diagnosis of femoral nerve dysfunction. Colour duplex sonography of the femoral artery and computed tomography of the lumbar spine and pelvis yielded no pathological findings. Overnight the neurological deficits decreased without therapy and were finally no longer detectable. We speculate that during the administration of the local anaesthetic a depot formed, localised in the medial femoral intermuscular septa, which was leaked after first mobilisation. To our knowledge no similar case has been published up to now. We conclude that patients who are treated with a nerve block should be informed and physician should be aware that delayed neurological deficits are possible. PMID:22577509

  3. Specialists meeting on properties of primary circuit structural materials including environmental effects

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-07-01

    The Specialists Meeting on Properties of Primary Circuit Structural Materials of LMFBRs covered the following topics: overview of materials program in different countries; mechanical properties of materials in air; fracture mechanics studies - component related activities; impact of environmental influences on mechanical properties; relationship of material properties and design methods. The purpose of the meeting was to provide a forum for exchange of information on structural materials behaviour in primary circuit of fast breeder reactors. Special emphasis was placed on environmental effects such as influence of sodium and irradiation on mechanical properties of reactor materials.

  4. Specialists meeting on properties of primary circuit structural materials including environmental effects

    International Nuclear Information System (INIS)

    1977-01-01

    The Specialists Meeting on Properties of Primary Circuit Structural Materials of LMFBRs covered the following topics: overview of materials program in different countries; mechanical properties of materials in air; fracture mechanics studies - component related activities; impact of environmental influences on mechanical properties; relationship of material properties and design methods. The purpose of the meeting was to provide a forum for exchange of information on structural materials behaviour in primary circuit of fast breeder reactors. Special emphasis was placed on environmental effects such as influence of sodium and irradiation on mechanical properties of reactor materials

  5. Fundamentals of semiconductors physics and materials properties

    CERN Document Server

    Yu, Peter Y

    2005-01-01

    Provides detailed explanations of the electronic, vibrational, transport, and optical properties of semiconductors. This textbook emphasizes understanding the physical properties of Si and similar tetrahedrally coordinated semiconductors and features an extensive collection of tables of material parameters, figures, and problems.

  6. Stress fracture of the femoral neck in a child (stress fracture)

    International Nuclear Information System (INIS)

    Coldwell, D.; Gross, G.W.; Boal, D.K.

    1984-01-01

    Femoral neck stress fracture is extremely rare in childhood. We report a case of femoral neck stress fracture in an 11-year-old girl. Differentials diagnosis and a brief review of the literature follow. (orig.)

  7. Aberrant femoral torsion presenting with frog-leg squatting mimicking gluteal muscle contracture.

    Science.gov (United States)

    Chiang, Chia-Ling; Tsai, Meng-Yuan; Chang, Wei-Ning; Chen, Clement Kuen-Huang

    2012-04-01

    Patients with frog-leg squatting have restricted internal rotation and adduction of the affected hips during sitting or squatting. In the surgical literature, the cause generally has been presumed to arise from and be pathognomonic for gluteal muscle contracture. However, we have encountered patients with frog-leg squatting but without gluteal muscle contracture. We therefore raised the following questions: What are the imaging features of patients with frog-leg squatting? Do conditions other than gluteal muscle contracture manifest frog-leg squatting? We retrospectively reviewed the MR images of 67 patients presenting with frog-leg squatting from April 1998 to July 2010. There were four females and 63 males; their mean age was 22.2 years (range, 4-50 years). During MRI readout, we observed aberrant axes of some femoral necks and obtained additional CT to measure femoral torsion angles in 59 of the 67 patients. MR images of 27 (40%) patients had signs of gluteal muscle contracture. Twenty-two (33%) patients (40 femora) had aberrant femoral torsion, including diminished anteversion (range, 6°-0°; average, 3.9°) in 11 femora of eight patients and femoral retroversion (range, muscle contracture or aberrant femoral torsion. The observation of aberrant femoral torsion was not anticipated before imaging studies. In addition to gluteal muscle contracture, aberrant femoral torsion can be a cause of frog-leg squatting. Level II, diagnostic study. See the guidelines for Authors for a complete description of levels of evidence.

  8. Does increased femoral antetorsion predispose to cartilage lesions of the patellofemoral joint?

    Science.gov (United States)

    Oppermann, Johannes; Bredow, Jan; Wissusek, Boris; Spies, Christian Karl; Boese, Christoph Kolja; Chang, Shi-Min; Eysel, Peer; Dargel, Jens

    2017-09-01

    The purpose of this study was to investigate whether there was a relationship between femoral neck antetorsion and the presence and pattern of osteoarthritis of the patellofemoral joint. It was hypothesized that an increased femoral neck antetorsion (1) correlates with osteoarthritic changes of the lateral facet of the patellofemoral joint and (2) correlates with an increased lateral trochlear height and a decreased sulcus angle. Seventy-eight formalin-embedded cadaveric lower extremities from thirty-nine subjects with a median age of 74 years (range 60-88) were used. Surrounding soft tissues of the lower limb were removed. The femoral neck antetorsion was measured and referenced to the transepicondylar axis and the posterior condylar line. The height of the medial and lateral facet of the trochlea and the sulcus angle was measured. The location and the degree of patellofemoral cartilage degeneration were recorded. A Pearson's correlation analysis was performed to correlate the femoral neck antetorsion with the measured knee parameters. No significant correlation could be found between the femoral antetorsion and cartilage degeneration of the lateral patellofemoral joint (n.s.), the height of the lateral trochlea (n.s.) and the sulcus angle (n.s.). This study could not document that the femoral neck antetorsion and subsequent internal rotation of the distal femur correlated with the degree of degeneration of the lateral facet of the patellofemoral joint. Clinically, femoral internal rotation may play a minor role in the development of lateral patellofemoral joint degeneration.

  9. Widening of the femoral proximal diaphysis--metaphysis angle in fetuses with achondroplasia.

    Science.gov (United States)

    Khalil, A; Morales-Roselló, J; Morlando, M; Bhide, A; Papageorghiou, A; Thilaganathan, B

    2014-07-01

    It has recently been reported that fetuses with achondroplasia have a wider than expected femoral proximal diaphysis-metaphysis angle (femoral angle). The aim of this case-control study was to investigate this finding. Cases with confirmed achondroplasia (n = 6), small-for-gestational-age fetuses (n = 70) and a group of normal fetuses (n = 377) were included in this study. The ultrasound image of the femur was examined by two independent experienced observers blinded to the diagnosis, who measured the femoral angle. These values were converted into multiples of the expected median (MoM), after adjustment for gestational age and femur length. Prevalence of various prenatal ultrasound signs of achondroplasia was determined in affected fetuses. Intra- and interobserver agreement of measurement of femoral angle was assessed using 95% limits of agreement and kappa statistics. The femoral angle can be measured accurately by ultrasound, and increases with both increasing gestational age and increasing femur length. The femoral angle-MoM was significantly higher in fetuses with achondroplasia than in the control group (1.36 vs 1.00 MoM, P achondroplasia (83.3%), which was the most consistent finding other than shortening of the long bones. The femoral angle is wider in fetuses with achondroplasia. This new ultrasound sign appears promising as an additional discriminatory marker when clinicians are faced with a case of short long bones in the third trimester. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  10. Important physical properties of peat materials

    Science.gov (United States)

    D.H. Boelter

    1968-01-01

    Peat materials from 12 bogs in northern Minnesota, U.S.A., showed significant differences in physical properties. It is pointed out that 1) these properties can be related to the hydrology of organic soils only if the soils represent undisturbed field conditions, and 2) volumetric expressions of water content are necessary to correctly evaluate the amount of water in a...

  11. Effects of Coal Gangue on Cement Grouting Material Properties

    Science.gov (United States)

    Liu, J. Y.; Chen, H. X.

    2018-05-01

    The coal gangue is one of the most abundant industrial solid wastes and pollute source of air and water. The use of coal gangue in the production of cement grouting material comforms to the basic state policy of environment protection and the circular using of natural resources. Through coal gangue processing experiment, coal gangue cement grouting materials making test, properties detection of properties and theoretical analysis, the paper studied the effects of coal gangue on the properties of cement grouting materials. It is found that at the range of 600 to 700 °C, the fluidity and the compressive and flexural strengths of the cement grouting materials increase with the rising up of the calcination temperatures of coal gangue. The optimum calcination temperature is around 700 °C. The part substitution of cement by the calcined coal gangue in the cement grouting material will improve the mechanical properties of the cement grouting material, even thought it will decrease its fluidity. The best substitution amount of cement by coal gangue is about 30%. The fluidity and the long term strength of the ordinary silicate cement grouting material is obviously higher than that of the sulphoaluminate cement one as well as that of the silicate-sulphoaluminate complex cement one.

  12. Isolated femoral hypoplasia: an intrauterine differential diagnosis to campomelia

    Energy Technology Data Exchange (ETDEWEB)

    Koerber, Friederike; Benz-Bohm, Gabriele [University of Cologne, Department of Paediatric Radiology, Cologne (Germany); Schoenau, Eckard [University of Cologne, Department of Paediatrics, Cologne (Germany); Horwitz, A.Eldad [Klinikum Krefeld, Department of Paediatric Radiology, Krefeld (Germany)

    2005-06-01

    The isolated form of femoral bowing is an important differential diagnosis of campomelia. Therefore, knowledge of isolated anomalies is fundamental for prenatal diagnosis, especially for the differential diagnosis from severe syndromes. Four cases are presented to discuss the differential diagnosis of femoral bowing including a review of the literature. We report four newborn babies with unilateral bowing and shortening of the femur. Three had no further anomaly; one child had additional abnormalities due to coumarin embryopathy. The radiological findings were shortened femora with bowing and varus deformity and cortical thickening on the concave side. All other parts showed normal bone structure. The aetiology of femoral bowing is unknown. Early damage of the cartilaginous model followed by remodelling with thickening on the concave side of the bone similar to the healing of malaligned fractures is suspected. The isolated form of femoral bowing without any other anomalies has to be differentiated from complex and more often severe congenital syndromes such as campomelia. Postpartum radiological examination should be reduced to a single exposure of the affected limb and follow-up should be done by clinical examination. (orig.)

  13. Transfer of obturator nerve for femoral nerve injury: an experiment study in rats.

    Science.gov (United States)

    Meng, Depeng; Zhou, Jun; Lin, Yaofa; Xie, Zheng; Chen, Huihao; Yu, Ronghua; Lin, Haodong; Hou, Chunlin

    2018-07-01

    Quadriceps palsy is mainly caused by proximal lesions in the femoral nerve. The obturator nerve has been previously used to repair the femoral nerve, although only a few reports have described the procedure, and the outcomes have varied. In the present study, we aimed to confirm the feasibility and effectiveness of this treatment in a rodent model using the randomized control method. Sixty Sprague-Dawley rats were randomized into two groups: the experimental group, wherein rats underwent femoral neurectomy and obturator nerve transfer to the femoral nerve motor branch; and the control group, wherein rats underwent femoral neurectomy without nerve transfer. Functional outcomes were measured using the BBB score, muscle mass, and histological assessment. At 12 and 16 weeks postoperatively, the rats in the experimental group exhibited recovery to a stronger stretch force of the knee and higher BBB score, as compared to the control group (p nerve with myelinated and unmyelinated fibers was observed in the experimental group. No significant differences were observed between groups at 8 weeks postoperatively (p > 0.05). Obturator nerve transfer for repairing femoral nerve injury was feasible and effective in a rat model, and can hence be considered as an option for the treatment of femoral nerve injury.

  14. The European Fusion Material properties database

    Energy Technology Data Exchange (ETDEWEB)

    Karditsas, P.J. [UKAEA Fusion, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)]. E-mail: panos.karditsas@ukaea.org.uk; Lloyd, G. [Tessella Support Services plc, 3 Vineyard Chambers, Abingdon OX14 3PX (United Kingdom); Walters, M. [Tessella Support Services plc, 3 Vineyard Chambers, Abingdon OX14 3PX (United Kingdom); Peacock, A. [EFDA Close Support Unit, Garching D-85748 (Germany)

    2006-02-15

    Materials research represents a significant part of the European and world effort on fusion research. A European Fusion Materials web-based relational database is being developed to collect, expand and preserve for the future the data produced in support of the NET, DEMO and ITER. The database allows understanding of material properties and their critical parameters for fusion environments. The system uses J2EE technologies and the PostgreSQL relational database, and flexibility ensures that new methods to automate material design for specific applications can be easily implemented. It runs on a web server and allows users access via the Internet using their preferred web browser. The database allows users to store, browse and search raw tests, material properties and qualified data, and electronic reports. For data security, users are issued with individual accounts, and the origin of all requests is checked against a list of trusted sites. Different user accounts have access to different datasets to ensure the data is not shared unintentionally. The system allows several levels of data checking/cleaning and validation. Data insertion is either online or through downloaded templates, and validation is through different expert groups, which can apply different criteria to the data.

  15. Outcomes of trochanteric femoral fractures treated with proximal femoral nail: an analysis of 100 consecutive cases.

    Science.gov (United States)

    Korkmaz, Mehmet Fatih; Erdem, Mehmet Nuri; Disli, Zeliha; Selcuk, Engin Burak; Karakaplan, Mustafa; Gogus, Abdullah

    2014-01-01

    In this study, we aimed to report the results of a retrospective study carried out at our institute regarding cases of patients who had suffered proximal femoral fractures between January 2002 and February 2007, and who were treated with a proximal femoral nail. One hundred consecutive cases were included in the study. A case documentation form was used to obtain intraoperative data including age, sex, mechanism of injury, type of fracture according to Association for Osteosynthesis/Association for the Study of Internal Fixation (AO/ASIF) classification and the American Society of Anesthesiologists' (ASA) physical status classification (ASA grade). Clinical and radiographic examinations were performed at the time of admission and at the 6th week; subsequent visits were organized on the 3rd month, 6th month, and 12th month, and in patients with longer follow-up and annually postoperatively. The Harris score of hip function was used, and any change in the position of the implants and the progress of the fracture union, which was determined radiologically, was noted. The mean age of the patients was 77.66 years (range: 37-98 years), and the sex distribution was 32 males and 68 females. Seventy-three fractures were reduced by closed means, whereas 27 needed limited open reduction. The mean follow-up time for the study group was 31.3 months (range: 12-75 months). Postoperative radiographs showed a near-anatomical fracture reduction in 78% of patients. The Harris hip score was negatively correlated with the ASA score and patient age. No cases of implant failure were observed. Three patients died before discharge (one due to pulmonary embolism, two due to cardiac arrest), and five patients died due to unrelated medical conditions within the first 3 months of the follow-up. Our study showed that proximal femoral nail is a reliable fixation with good fracture union, and it is not associated with major complications in any type of trochanteric femoral fracture.

  16. Multiple bony lesions other than femoral heads on {sup 99m}Tc-MDP bone scan in patients with avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yun Young; Yang, Seoung Oh; Moon, Dae Hyuk; Ryu, Jin Sook; Weon, Young Cheol; Shin, Myung Jin; Lee, Soo Ho; Lee, Hee Kyung [Asan Medical Center, Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of); Chun, Hae Kyung [St. Francisco Hospital, Seoul (Korea, Republic of)

    1997-03-01

    To evaluate the clinical significance of the multiple increased uptake lesions other than in femoral heads as seen on whole body bone scan in patients with avascular necrosis of femoral heads. One hundred and seventy three patients with clinical diagnosis of avascular necrosis of the emoral head underwent a bone scan using Tc-99m MDP. Increased uptake lesions other than in femoral heads were evaluated, including frequency and common sites of in volvement, and correlated with clinical information and plain radiographic findings. Two hundred patients without AVN, who had undergone a bone scan, were included as a control group. Increased uptake lesions in extrafemoral head locations were found in 36 of 173 patients(20.8%); the location of 79 lesions was other than the femoral head. This result is statistically different from patients without avascular necrosis of femoral head(p<0.0001). The most common site of involvement was the knee joint area(62.5%). Other lesions were located in the mid-shafts of the long bones of the lower extremities, calcaneus, proximal humerus, etc., in order of decreasing frequency. Plain radiographs of 17 lesions were nonspecific, except for three lesions showing definite changes associated with avascular necrosis. The risk factors included alcoholism, the prolonged use of steroids, renal transplantation, herbal medication and working as a working as deep-sea diver. Most patients did not complain of pain, except for two with irreversible osteonecrotic changes as seen on plain radiograph. in patients with avascular necrosis of the femur, increased uptake lesions other than in the femoral head as seen on bone scan, may represent the early stage of osteonecrosis, which shows a characteristic appearance on bone scan. In order to aveid possible misdiagnoses of multiple extrafemoral lesions as bony metastasis or traumatic lesions, in patients with avascular necrosis of the femur these should be carefully evaluated.

  17. Traumatic subchondral fracture of the femoral head in a healed trochanteric fracture.

    Science.gov (United States)

    Lee, Sang Yang; Niikura, Takahiro; Iwakura, Takashi; Kurosaka, Masahiro

    2014-07-11

    An 82-year-old woman sustained a trochanteric fracture of the left femur after a fall. Fracture fixation was performed using proximal femoral nail antirotation (PFNA) II, and she was able to walk with a T-cane after 3 months. Eleven months following the operation, the patient presented with left hip pain after a fall. Radiographs showed a subchondral collapse of the femoral head located above the blade tip. The authors removed the PFNA-II and subsequently performed cemented bipolar hemiarthroplasty. Histological evaluation of the femoral head showed osteoporosis with no evidence of osteonecrosis. Repair tissue, granulation tissue and callus formation were seen at the collapsed subchondral area. Based on these findings, a traumatic subchondral fracture of the femoral head in a healed trochanteric fracture was diagnosed. A traumatic subchondral fracture of the femoral head may need to be considered as a possible diagnosis after internal fixation of the trochanteric fracture. 2014 BMJ Publishing Group Ltd.

  18. Osteosynthesis of ununited femoral neck fracture by internal fixation combined with iliac crest bone chips and muscle pedicle bone grafting

    Directory of Open Access Journals (Sweden)

    D D Baksi

    2016-01-01

    Full Text Available Background: Ununited femoral neck fracture is seen commonly in developing countries due to delayed presentation or failure of primary internal fixation. Such fractures, commonly present with partial or total absorption of femoral neck, osteonecrosis of femoral head in 8-30% cases with upward migration of trochanter posing problem for osteosynthesis, especially in younger individuals. Several techniques for treatment of such conditions are described like osteotomies or nonvascularied cortical or cancellous bone grafting provided varying degrees of success in terms of fracture union but unsatisfactory long term results occurred due to varying incidence of avascular necrosis (AVN of femoral head. Moreover, in presence of AVN of femoral head neither free fibular graft nor cancellous bone graft is satisfactory. The vascularied bone grafting by deep circumflex iliac artery based on iliac crest bone grafting, free vascularied fibular grafting and muscle pedicle periosteal grafting showed high incidence of success rate. Osteosynthesis is the preferred treatment of choice in ununited femoral neck fracture in younger individuals. Materials and Methods: Of the 293 patients operated during the period from June 1977 to June 2009, 42 were lost to followup. Seven patients with gluteus medius muscle pedicle bone grafting (MPBG were excluded. Thus, out of 244 patients, 208 (85.3% untreated nonunion and 36 (14.7% following failure of primary internal fixation were available for studies. Time interval between the date of injury and operation in untreated nonunion cases was mean 6.5 months and in failed internal fixation cases was mean 11.2 months. Ages of the patients varied from 16 to 55 years. Seventy patients had partial and 174 had subtotal absorption of the femoral neck. Evidence of avascular necrosis (AVN femoral head was found histologically in 135 (54.3% and radiologically in 48 (19.7% patients. The patients were operated by open reduction of fracture

  19. International nuclear safety center database on material properties

    International Nuclear Information System (INIS)

    Fink, J.K.

    1996-01-01

    International nuclear safety center database on the following material properties is described: fuel, cladding,absorbers, moderators, structural materials, coolants, concretes, liquid mixtures, uranium dioxide

  20. Development and application of computer assisted optimal method for treatment of femoral neck fracture.

    Science.gov (United States)

    Wang, Monan; Zhang, Kai; Yang, Ning

    2018-04-09

    To help doctors decide their treatment from the aspect of mechanical analysis, the work built a computer assisted optimal system for treatment of femoral neck fracture oriented to clinical application. The whole system encompassed the following three parts: Preprocessing module, finite element mechanical analysis module, post processing module. Preprocessing module included parametric modeling of bone, parametric modeling of fracture face, parametric modeling of fixed screw and fixed position and input and transmission of model parameters. Finite element mechanical analysis module included grid division, element type setting, material property setting, contact setting, constraint and load setting, analysis method setting and batch processing operation. Post processing module included extraction and display of batch processing operation results, image generation of batch processing operation, optimal program operation and optimal result display. The system implemented the whole operations from input of fracture parameters to output of the optimal fixed plan according to specific patient real fracture parameter and optimal rules, which demonstrated the effectiveness of the system. Meanwhile, the system had a friendly interface, simple operation and could improve the system function quickly through modifying single module.

  1. Ipsilateral femoral shaft and vertical patella fracture: a case report

    Science.gov (United States)

    Ozkan, Korhan; Eceviz, Engin; Sahin, Adem; Ugutmen, Ender

    2009-01-01

    Introduction A femoral shaft fracture with an ipsilateral patella fracture has been, to our knowledge, given only cursory attention in English-speaking literature. Case presentation A 15 year old male patient had hitten by a car to his motorcycle came to emergency room and he had been operated for his femoral shaft freacture and vertical patellar fracture which was iniatally missed. Conclusion To us it is vital to obtain CT scan of the patient’s knee if there is an ipsilateral femoral fracture with an ipsilateral knee effusion and a punction which reveals hematoma even in the absence of a fracture line seen in AP and lateral projections. PMID:19829933

  2. Incidence and predictors of post-catheterization femoral artery pseudoaneurysms

    OpenAIRE

    Kassem, Hussein Heshmat; Elmahdy, Mahmoud Farouk; Ewis, Essam Baligh; Mahdy, Soilman Ghareeb

    2013-01-01

    Background: Femoral artery pseudoaneurysm (FAP) is a troublesome complication after transfemoral catheter procedures. The incidence and predictors of FAP as a separate entity have not been extensively studied. Aim: Detect prospectively the incidence and predictors of post catheterization FAP. Methods: From June 2009 till June 2011, we prospectively included all patients who underwent catheterization from the femoral approach. Duplex ultrasound was performed in cases with clinical suspic...

  3. [Treatment of femoral neck fracture--preference to internal fixation].

    Science.gov (United States)

    Minato, Izumi

    2011-03-01

    In the guidelines for the treatment of femoral neck fracture, prosthetic replacement is recommended in displaced one and internal fixation is in undisplaced one. However, in the long view, survived femoral head after internal fixation can be superior to prosthesis which will deteriorate as time goes by. Surgical method should be considered not only by type of fracture but general status of the patient.

  4. The influence of protective properties of packaging materials and ...

    African Journals Online (AJOL)

    The influence of protective properties of packaging materials and modified atmosphere on quality changes of dried apricot is shown in this paper. In our investigation, we used four different characteristic combinations of packaging materials with different barrier properties for packaging of dried apricot: ...

  5. Functional morphology of femoral glands in the Tegu lizard, Tupinambis merianae.

    Science.gov (United States)

    Chamut, Silvia; Valdez, Valeria García; Manes, Mario E

    2009-04-01

    Several lizards have femoral glands, which have an influence in various reproductive behaviors. In this paper we describe the morphological organization of the femoral glands in the Tegu, Tupinambis merianae, by means of light and electron microscopy. Even though these glands are present in both genders, secretions during the reproductive period can only be found in males. The glandular parenchyma, which is organized in numerous secretory units, consists of keratinocyte-like cells and granular cells. The holocrine secretion is constituted from both cells, which lose their integrity and become a semi-amorphous material, reinforced by keratin sheets. The discharges of each unit merge together into a solid cylinder of secretion, surrounded by epithelial cells, that is extruded to the exterior. The keratin sheets and epithelial layers that surround both the complete and partial secretions form a sort of structural support suitable for the type of territorial demarcation characteristic of the species. The granular cells, supposedly the producers of pheromones, are characterized by the presence of electron-dense granules and multilaminar membranous bodies that show ultrastructural changes of unknown function. The free granules in the secretion cylinder may act as pheromone deposits.

  6. Modern permanent magnetic materials - preparation and properties

    International Nuclear Information System (INIS)

    Rodewald, W.

    1989-01-01

    First of all, the basic properties of the classical (steel, AlNiCo) permanent magnetic materials and the modern rare-earth (RE) permanent magnetic materials are compared. Since the properties of RE permanent magnets depend on the particular production process, the fundamentals of the main industrial processes (powder metallurgy, rapid-solidification technique) are described and the typical properties are explained. Furthermore the production processes in development such as mechanical alloying, melt spinning technique and extrusion upsetting are briefly outlined. For applying the permanent magnets, they have to be completely magnetized. The magnetization behaviour of the various RE permanent magnets is discussed by means of the internal demagnetization curve. Finally the various influences on the temperature stability of RE permanent magnets are compiled. (orig./MM) [de

  7. Material physical properties of 11Cr-ferritic/martensitic steel (PNC-FMS) wrapper tube materials

    International Nuclear Information System (INIS)

    Yano, Yasuhide; Kaito, Takeji; Ohtsuka, Satoshi; Tanno, Takashi; Uwaba, Tomoyuki; Koyama, Shinichi

    2012-09-01

    It is necessary to develop core materials for fast reactors in order to achieve high-burnup. Ferritic steels are expected to be good candidate core materials to achieve this objective because of their excellent void swelling resistance. Therefore, oxide dispersion strengthened (ODS) ferritic steel and 11Cr-ferritic/martensitic steel (PNC-FMS) have been respectively developed for cladding and wrapper tube materials in Japan Atomic Energy Agency. In this study, various physical properties of PNC-FMS wrapper materials were measured and equations and future standard measurement technique of physical properties for the design and evaluation were conducted. (author)

  8. Subchondral bone density distribution in the human femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Wright, David A.; Meguid, Michael; Lubovsky, Omri; Whyne, Cari M. [Sunnybrook Research Institute, Orthopaedic Biomechanics Laboratory, Toronto, Ontario (Canada)

    2012-06-15

    This study aims to quantitatively characterize the distribution of subchondral bone density across the human femoral head using a computed tomography derived measurement of bone density and a common reference coordinate system. Femoral head surfaces were created bilaterally for 30 patients (14 males, 16 females, mean age 67.2 years) through semi-automatic segmentation of reconstructed CT data and used to map bone density, by shrinking them into the subchondral bone and averaging the greyscale values (linearly related to bone density) within 5 mm of the articular surface. Density maps were then oriented with the center of the head at the origin, the femoral mechanical axis (FMA) aligned with the vertical, and the posterior condylar axis (PCA) aligned with the horizontal. Twelve regions were created by dividing the density maps into three concentric rings at increments of 30 from the horizontal, then splitting into four quadrants along the anterior-posterior and medial-lateral axes. Mean values for each region were compared using repeated measures ANOVA and a Bonferroni post hoc test, and side-to-side correlations were analyzed using a Pearson's correlation. The regions representing the medial side of the femoral head's superior portion were found to have significantly higher densities compared to other regions (p < 0.05). Significant side-to-side correlations were found for all regions (r {sup 2} = 0.81 to r {sup 2} = 0.16), with strong correlations for the highest density regions. Side-to-side differences in measured bone density were seen for two regions in the anterio-lateral portion of the femoral head (p < 0.05). The high correlation found between the left and right sides indicates that this tool may be useful for understanding 'normal' density patterns in hips affected by unilateral pathologies such as avascular necrosis, fracture, developmental dysplasia of the hip, Perthes disease, and slipped capital femoral head epiphysis. (orig.)

  9. Avascular necrosis of femoral head: findings of contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Shin, Yong Moon; Kang, Heung Sik; Kim, Chu Wan; Kim, Hee Joong; Kim, Young Min

    1995-01-01

    To evaluate the findings and the role of contrast enhanced magnetic resonance imaging in avascular necrosis of femoral head. Sixteen patients with avascular necorsis of femoral head were examined with MRI. T1-weighted and T2-weighted image and contrast-enhanced T1-weighted images were obtained. Enhancing characteristics of the necrotic area and synovium were determined. Also a change of the disease extent after enhancement was assessed. Twenty seven avascular necrosis of the femoral head including 11 cases of bilateral lesion were detected. Fifteen cases revealed collapse of the femoral head. The portions of the lesion with low signal intensity on T1-weighted images and high signal intensity on T2-weighted images showed contrast enhancement in 15 cases. However, the potions with low signal intensities both on T1 and T2-weighted images showed enhancement in one case. There was no significant change of the disease extent after enhancement. Synovium showed enhancement in 18 cases, and joint effusion was detected in 23 cases. Contrast enhanced MR images may be helpful in predicting histopathologic findings of avascular necrosis of the femoral head, but not useful for evaluating the extent of disease

  10. Avascular necrosis of femoral head: findings of contrast-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Yong Moon; Kang, Heung Sik; Kim, Chu Wan; Kim, Hee Joong; Kim, Young Min [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1995-06-15

    To evaluate the findings and the role of contrast enhanced magnetic resonance imaging in avascular necrosis of femoral head. Sixteen patients with avascular necorsis of femoral head were examined with MRI. T1-weighted and T2-weighted image and contrast-enhanced T1-weighted images were obtained. Enhancing characteristics of the necrotic area and synovium were determined. Also a change of the disease extent after enhancement was assessed. Twenty seven avascular necrosis of the femoral head including 11 cases of bilateral lesion were detected. Fifteen cases revealed collapse of the femoral head. The portions of the lesion with low signal intensity on T1-weighted images and high signal intensity on T2-weighted images showed contrast enhancement in 15 cases. However, the potions with low signal intensities both on T1 and T2-weighted images showed enhancement in one case. There was no significant change of the disease extent after enhancement. Synovium showed enhancement in 18 cases, and joint effusion was detected in 23 cases. Contrast enhanced MR images may be helpful in predicting histopathologic findings of avascular necrosis of the femoral head, but not useful for evaluating the extent of disease.

  11. Avascular necrosis of the femoral head in HIV infected patients

    Directory of Open Access Journals (Sweden)

    Marcos Almeida Matos

    Full Text Available Avascular necrosis (AVN of the femoral head is an emerging complication in HIV infected patients. It has been suggested that the increased incidence of AVN in this population may be caused by an increased prevalence of predisposing factors for osteonecrosis, including protease inhibitors, hyperlipidemia, corticosteroid use, alcohol and intravenous drug abuse. The aim of this study was to assess the risk factors for avascular necrosis developing in the femoral head of HIV infected individuals. This study consisted of meta-analysis of the secondary data extracted from current literature. The selected articles allowed two study groups to be drawn up for comparison. Group 1 comprised 324 individuals infected by the HIV virus, who did not present femoral head AVN. Group 2 comprised 32 HIV positive patients, who presented femoral head AVN. The parameters used for analysis were as follows: age, gender, sexual preference, use of intravenous drugs, time of diagnosis, CD4+ cell count, use of antiretroviral agents and duration, serum cholesterol and serum triglycerides. The present study found a statistically significant association between hypertriglyceridemia, hypercholesterolemia, sexual preference and intravenous drug abuse. The authors concluded that femoral head osteonecrosis is associated with hyperlipidemia (hypercholesterolemia and hypertriglyceridemia and intravenous drug abuse. This study supports the hypothesis that protease inhibitors play a role in the development of osteonecrosis through a tendency to cause hyperlipidemia.

  12. Thermomechanical properties of mullitic materials

    Directory of Open Access Journals (Sweden)

    Jan Urbánek

    2017-12-01

    Full Text Available Mechanical tests provide important information about the properties and behaviour of materials. Basic tests include the measurement of flexural strength and in case of refractory materials, the measurement of flexural strength at high temperatures as well. The dependence of flexural strength on the temperature of ceramic materials usually exhibits a constant progression up to a certain temperature, where the material starts to melt and so the curve begins to decline. However, it was discovered that ceramic mullitic material with a 63 wt.% of Al2O3 exhibits a relatively significant maximum level of flexural strength at about 1000 °C and refractory mullitic material with a 60 wt.% of Al2O3 also exhibits a similar maximum level at about 1100 °C. The mentioned maximum is easily reproducible, but it has no connection with the usual changes in structure of material during heating. The maximum was also identified by another measurement, for example from the progression of the dynamic Young’s modulus or from deflection curves. The aim of this work was to analyse and explain the reason for the flexural strength maximum of mullitic materials at high temperatures.

  13. Emergency Stenting of a Ruptured Infected Anastomotic Femoral Pseudoaneurysm

    International Nuclear Information System (INIS)

    Klonaris, Chris; Katsargyris, Athanasios; Matthaiou, Alexandros; Giannopoulos, Athanasios; Tsigris, Chris; Papadopouli, Katerina; Tsiodras, Sotiris; Bastounis, Elias

    2007-01-01

    A 74-year-old man presented with a ruptured infected anastomotic femoral pseudoaneurysm. Due to severe medical comorbidities he was considered unsuitable for conventional surgical management and underwent an emergency endovascular repair with a balloon-expandable covered stent. The pseudoaneurysm was excluded successfully and the patient had an uneventful postoperative recovery with long-term suppressive antimicrobials. He remained well for 10 months after the procedure with no signs of recurrent local or systemic infection and finally died from an acute myocardial infarction. To our knowledge, emergency endovascular treatment of a free ruptured bleeding femoral artery pseudoaneurysm has not been documented before in the English literature. This case illustrates that endovascular therapy may be a safe and efficient alternative in the emergent management of ruptured infected anastomotic femoral artery pseudoaneurysms when traditional open surgery is contraindicated

  14. Femoral hip prosthesis design for Thais using multi-objective shape optimization

    International Nuclear Information System (INIS)

    Virulsri, Chanyaphan; Tangpornprasert, Pairat; Romtrairat, Parineak

    2015-01-01

    Highlights: • A multi-objective shape optimization was proposed to design hip prosthesis for Thais. • The prosthesis design was optimized in terms of safety of both cement and prosthesis. • The objective functions used the Soderberg fatigue strength formulations. • Safety factors of the cement and prosthesis are 1.200 and 1.109 respectively. • The newly designed prosthesis also fits well with chosen small-sized Thai femurs. - Abstract: The long-term success of Total Hip Arthroplasty (THA) depends largely on how well the prosthetic components fit the bones. The majority of cemented femoral hip prosthesis failures are due to aseptic loosening, which is possibly caused by cracking of the cement mantle. The strength of cement components is a function of cement mantles having adequate thickness. Since the size and shape of cemented femoral hip prostheses used in Thailand are based on designs for a Caucasian population, they do not properly conform to most Thai patients’ physical requirements. For these reasons, prostheses designed specifically for Thai patients must consider the longevity and functionality of both cement and prosthesis. The objective of this study was to discover a new design for femoral hip prostheses which is not only optimal and safe in terms of both cement and prosthesis, but also fits the selected Thai femur. This study used a small-sized Thai femoral model as a reference model for a new design. Biocompatible stainless steel 316L (SS316L) and polymethylmethacrylate (PMMA) were selected as raw materials for the prosthesis and bone cement respectively. A multi-objective shape optimization program, which is an interface between optimization C program named NSGA-II and a finite element program named ANSYS, was used to optimize longevity of femoral hip prostheses by varying shape parameters at assigned cross-sections of the selected geometry. Maximum walking loads of sixty-kilograms were applied to a finite element model for stress and

  15. Femoral Artery Stenosis Following Percutaneous Closure Using a Starclose Closure Device

    International Nuclear Information System (INIS)

    Bent, Clare Louise; Kyriakides, Constantinos; Matson, Matthew

    2008-01-01

    Starclose (Abbott Vascular Devices, Redwood City, CA) is a new arterial closure device that seals a femoral puncture site with an extravascular star-shaped nitinol clip. The clip projects small tines into the arterial wall which fold inward, causing the arterial wall to pucker, producing a purse-string-like seal closing the puncture site. The case history is that of a 76-year-old female patient who underwent day-case percutaneous diagnostic coronary angiography. A Starclose femoral artery closure device was used to achieve hemostasis with subsequent femoral artery stenosis.

  16. [Growth and deformity after in situ fixation of slipped capital femoral epiphysis].

    Science.gov (United States)

    Druschel, C; Placzek, R; Funk, J F

    2013-08-01

    For mild to moderate slipped capital femoral epiphysis (SCFE) in situ fixation is the current treatment standard. However, concerning the implant selection (screw versus k-wires) as well as the prophylactic stabilisation of the non-affected hip, controversies still exist. The aim of this study was to analyse femoral residual growth and femoral deformities after in situ fixation of SCFE either with k-wires or screws. We conducted a retrospective analysis of the radiographs of adolescents treated for SCFE in our department between 01/2003 and 02/2011. To evaluate femoral growth the articulo-trochanteric distance, centro-trochanteric distance, caput-collum-diaphyseal angle, pin-joint ratio and pin-physis ratio were determined. The femoral deformity was assessed by measuring the sphericity of the femoral head. Degenerative changes were evaluated in the final radiographs. Statistical analysis was performed concerning differences between therapeutically and prophylactically treated hips as well as stabilisations with k-wires and screws. A total of 22 patients (female : male = 14 : 8, mean age girls: 11 ± 1 years, boys: 13 ± 2 years) with 26 slipped capital femoral epiphyses was analysed. K-wires were used for fixation in 4 hips each therapeutically and prophylactically, 22 hips with SCFE and 14 non-affected hips were stabilised with screws. Treatment with screws did not lead to significantly earlier physeal closure than k-wire pinning. Regarding the femoral growth parameters a significant decrease in the articulo-trochanteric distance and CCD angle was detectable in all groups. The pin-joint ratio revealed an adequate residual growth in 58 % of the therapeutically and in 72 % of the prophylactically treated hips without significant difference between k-wires and screws. The pin-physis ratio demonstrated similar values. Regarding the femoral deformity the SCFE hips resulted in a significantly reduced sphericity, which remained unchanged during follow-up. The

  17. Prognostic value of dynamic MRI in assessing post-traumatic femoral head vascularity

    Energy Technology Data Exchange (ETDEWEB)

    Kaushik, Abhishek; Varghese, Mathew [St Stephen' s Hospital, Department of Orthopaedics, Delhi, New Delhi (India); Sankaran, Balu [St Stephen' s Hospital, Delhi, New Delhi (India)

    2009-06-15

    The vascular status of femoral heads in the post-traumatic period of intracapsular femoral neck fracture (ICFNF) remains uncertain until the patient actually develops avascular necrosis (AVN). Several methods for predicting the viability of femoral head have been reported, that are not effective or widely used because of unreliability, potential complications, and technical difficulties. The present study involved the use of Dynamic MRI (DMRI) in assessing femoral head vascularity to predict AVN. The role of DMRI was studied prospectively in 30 patients with 31 ICFNF. Fractures were divided in to three types (Type A, B, or C) based on the femoral head vascularity shown by dynamic curve patterns on MRI evaluation. Type A was preserved vascularity, Type B was some decrease in vascularity but still viable while Type C was significantly reduced vascularity. These were followed-up for 6 months to 2 years to observe the final outcome in terms of union, non-union, or AVN. We found that Type A curves correlate well with vascular status and Type C curves correlate well with poor vascularity of the femoral heads. No AVN was seen in any of Type A (13/31) or Type B (eight out of 31). Five cases showed AVN and all of them were of Type C dynamic curves. Dynamic MRI is a reliable tool to evaluate vascularity of femoral heads and thus reduces the uncertainty of outcome of treatment of ICFNFs. DMRI can be a useful tool to formulate a treatment algorithm in management of ICFNF. (orig.)

  18. Arthroscopic treatment of femoral nerve paresthesia caused by an acetabular paralabral cyst.

    Science.gov (United States)

    Kanauchi, Taira; Suganuma, Jun; Mochizuki, Ryuta; Uchikawa, Shinichi

    2014-05-01

    This report describes a rare case of femoral nerve paresthesia caused by an acetabular paralabral cyst of the hip joint. A 68-year-old woman presented with a 6-month history of right hip pain and paresthesia along the anterior thigh and radiating down to the anterior aspect of the knee. Radiography showed osteoarthritis with a narrowed joint space in the right hip joint. Magnetic resonance imaging showed a cyst with low T1- and high T2-weighted signal intensity arising from a labral tear at the anterior aspect of the acetabulum. The cyst was connected to the joint space and displaced the femoral nerve to the anteromedial side. The lesion was diagnosed as an acetabular paralabral cyst causing femoral neuropathy. Because the main symptom was femoral nerve paresthesia and the patient desired a less invasive procedure, arthroscopic labral repair was performed to stop synovial fluid flow to the paralabral cyst that was causing the femoral nerve paresthesia. After surgery, the cyst and femoral nerve paresthesia disappeared. At the 18-month follow-up, the patient had no recurrence. There have been several reports of neurovascular compression caused by the cyst around the hip joint. To the authors' knowledge, only 3 cases of acetabular paralabral cysts causing sciatica have been reported. The current patient appears to represent a rare case of an acetabular paralabral cyst causing femoral nerve paresthesia. The authors suggest that arthroscopic labral repair for an acetabular paralabral cyst causing neuropathy can be an option for patients who desire a less invasive procedure. Copyright 2014, SLACK Incorporated.

  19. Prognostic value of dynamic MRI in assessing post-traumatic femoral head vascularity

    International Nuclear Information System (INIS)

    Kaushik, Abhishek; Varghese, Mathew; Sankaran, Balu

    2009-01-01

    The vascular status of femoral heads in the post-traumatic period of intracapsular femoral neck fracture (ICFNF) remains uncertain until the patient actually develops avascular necrosis (AVN). Several methods for predicting the viability of femoral head have been reported, that are not effective or widely used because of unreliability, potential complications, and technical difficulties. The present study involved the use of Dynamic MRI (DMRI) in assessing femoral head vascularity to predict AVN. The role of DMRI was studied prospectively in 30 patients with 31 ICFNF. Fractures were divided in to three types (Type A, B, or C) based on the femoral head vascularity shown by dynamic curve patterns on MRI evaluation. Type A was preserved vascularity, Type B was some decrease in vascularity but still viable while Type C was significantly reduced vascularity. These were followed-up for 6 months to 2 years to observe the final outcome in terms of union, non-union, or AVN. We found that Type A curves correlate well with vascular status and Type C curves correlate well with poor vascularity of the femoral heads. No AVN was seen in any of Type A (13/31) or Type B (eight out of 31). Five cases showed AVN and all of them were of Type C dynamic curves. Dynamic MRI is a reliable tool to evaluate vascularity of femoral heads and thus reduces the uncertainty of outcome of treatment of ICFNFs. DMRI can be a useful tool to formulate a treatment algorithm in management of ICFNF. (orig.)

  20. A new method for measurement of femoral anteversion using 3D imaging technique

    International Nuclear Information System (INIS)

    Kim, S.I.; Lee, Y.H.; Park, S.-B.; Lee, K.-M.

    1996-01-01

    Conventional methods that use cross-sectional computed tomography (CT) images to estimate femoral anteversion have several problems because of the complex 3 dimensional structure of the femur. These are the ambiguity of defining the femoral neck axis and condylar line, and the dependence on patient positioning. Especially, the femoral neck axis that is known as a major source of error is hard to determine from a single or multiple 2-dimensional transverse CT images. In this study, we are presenting a new method that we have devised form the measurement of femoral anteversion by utilizing the 3 dimensional imaging technique. Poster 176. (author)

  1. Long-term functional outcome following intramedullary nailing of femoral shaft fractures

    NARCIS (Netherlands)

    el Moumni, Mostafa; Voogd, Emma Heather; ten Duis, Henk Jan; Wendt, Klaus Wilhelm

    Background: The management of femoral shaft fractures using intramedullary nailing is a popular method. The purpose of this study was to evaluate the long-term functional outcome after antegrade or retrograde intramedullary nailing of traumatic femoral shaft fractures. We further determined

  2. Fourier Transformed Infra-Red Imaging of Femoral Neck Bone: Reduced Heterogeneity of Mineral-to-Matrix and Carbonate-to-Phosphate and more Variable Crystallinity in Treatment-Naïve Fracture Cases compared to Fracture-Free Controls

    Science.gov (United States)

    Gourion-Arsiquaud, Samuel; Lukashova, Lyudmilla; Power, Jon; Loveridge, Nigel; Reeve, Jonathan; Boskey, Adele L.

    2012-01-01

    After age 60 hip fracture risk strongly increases, but only a fifth of this increase is attributable to reduced mineral density (BMD, measured clinically). Changes in bone quality, specifically bone composition as measured by Fourier Transform Infrared spectroscopic imaging (FTIRI), also contribute to fracture risk. Here, FTIRI was applied to study the femoral neck and provide spatially derived information on its mineral and matrix properties in age-matched fractured and non-fractured bones. Whole femoral neck cross sections, divided into quadrants along the neck’s axis, from 10 women with hip fracture and 10 cadaveric controls were studied using FTIRI and micro-computed Tomography. Although 3-dimensional micro-CT bone mineral densities were similar, the mineral-to-matrix ratio was reduced in the cases of hip fracture, confirming previous reports. New findings were that the FTIRI microscopic variation (heterogeneity) of the mineral-to-matrix ratio was substantially reduced in the fracture group as was the heterogeneity of the carbonate-to-phosphate ratio. Conversely, the heterogeneity of crystallinity was increased. Increased variation of crystallinity was statistically associated with reduced variation of the carbonate-to-phosphate ratio. Anatomical variation in these properties between the different femoral neck quadrants was reduced in the fracture group compared to controls. While our treatment-naïve patients had reduced rather than increased bending resistance, these changes in heterogeneity associated with hip fracture are in another way comparable to the effects of experimental bisphosphonate therapy, which decreases heterogeneity and other indicators of bone’s toughness as a material. PMID:22865771

  3. A smart predictor for material property testing

    International Nuclear Information System (INIS)

    Wang, Wilson; Kanneg, Derek

    2008-01-01

    A reliable predictor is very useful for real-world industrial applications to forecast the future behavior of dynamic systems. A smart predictor, based on a novel recurrent neural fuzzy (RNF) scheme, is developed in this paper for multi-step-ahead prediction of material properties. A systematic investigation based on two benchmark data sets is conducted in terms of performance and efficiency. Analysis results reveal that, of the data-driven forecasting schemes, predictors based on step input patterns outperform those based on sequential input patterns; the RNF predictor outperforms those based on recurrent neural networks and ANFIS schemes in multi-step-ahead prediction of nonlinear time series. An adaptive Levenberg–Marquardt training technique is adopted to improve the robustness and convergence of the RNF predictor. Furthermore, the proposed smart predictor is implemented for material property testing. Investigation results show that the developed RNF predictor is a reliable forecasting tool for material property testing; it can capture and track the system's dynamic characteristics quickly and accurately. It is also a robust predictor to accommodate different system conditions

  4. The design and modeling of periodic materials with novel properties

    Science.gov (United States)

    Berger, Jonathan Bernard

    Cellular materials are ubiquitous in our world being found in natural and engineered systems as structural materials, sound and energy absorbers, heat insulators and more. Stochastic foams made of polymers, metals and even ceramics find wide use due to their novel properties when compared to monolithic materials. Properties of these so called hybrid materials, those that combine materials or materials and space, are derived from the localization of thermomechanical stresses and strains on the mesoscale as a function of cell topology. The effects of localization can only be generalized in stochastic materials arising from their inherent potential complexity, possessing variations in local chemistry, microstructural inhomogeneity and topological variations. Ordered cellular materials on the other hand, such as lattices and honeycombs, make for much easier study, often requiring analysis of only a single unit-cell. Theoretical bounds predict that hybrid materials have the potential to push design envelopes offering lighter stiffer and stronger materials. Hybrid materials can achieve very low and even negative coefficients of thermal expansion (CTE) while retaining a relatively high stiffness -- properties completely unmatched by monolithic materials. In the first chapter of this thesis a two-dimensional lattice is detailed that possess near maximum stiffness, relative to the tightest theoretical bound, and low, zero and even appreciably negative thermal expansion. Its CTE and stiffness are given in closed form as a function of geometric parameters and the material properties. This result is confirmed with finite elements (FE) and experiment. In the second chapter the compressive stiffness of three-dimensional ordered foams, both closed and open cell, are predicted with FE and the results placed in property space in terms of stiffness and density. A novel structure is identified that effectively achieves theoretical bounds for Young's, shear and bulk modulus

  5. Understanding Materials Science History · Properties · Applications

    CERN Document Server

    Hummel, Rolf E

    2005-01-01

    This introduction to materials science both for students of engineering and physics and for the interested general public examines not only the physical and engineering properties of virtually all kinds of materials, but also their history, uses, development, and some of the implications of resource depletion and recycling. It covers all topics on materials from an entirely novel perspective: the role materials have played throughout history in the development of humankind and technologies. Specifically, it shows the connection between the technical and the cultural, economic, ecological, and societal aspects of materials science. It aims to whet the appetite of its readers and inspire them to further explore the properties and applications of metals, alloys, ceramics, plastics, and electronic materials by presenting easily understandable explanations and entertaining historical facts. It is also intended to raise the reader’s awareness of their obligations to society as practicing engineers and scientists....

  6. Bilateral impacted femoral neck fracture in a renal disease patient ...

    African Journals Online (AJOL)

    Spontaneous bilateral femoral neck facture in a renal disease patient is not common. We report a case of 47-year-old female patient with chronic renal failure and on regular hemodialysis for the past 5 years who sustained bilateral impacted femoral neck fracture without history of trauma and injury and refused any surgical ...

  7. Benefit of cup medialization in total hip arthroplasty is associated with femoral anatomy.

    Science.gov (United States)

    Terrier, Alexandre; Levrero Florencio, Francesc; Rüdiger, Hannes A

    2014-10-01

    Medialization of the cup with a respective increase in femoral offset has been proposed in THA to increase abductor moment arms. Insofar as there are potential disadvantages to cup medialization, it is important to ascertain whether the purported biomechanical benefits of cup medialization are large enough to warrant the downsides; to date, studies regarding this question have disagreed. The purpose of this study was to quantify the effect of cup medialization with a compensatory increase in femoral offset compared with anatomic reconstruction for patients undergoing THA. We tested the hypothesis that there is a (linear) correlation between preoperative anatomic parameters and muscle moment arm increase caused by cup medialization. Fifteen patients undergoing THA were selected, covering a typical range of preoperative femoral offsets. For each patient, a finite element model was built based on a preoperative CT scan. The model included the pelvis, femur, gluteus minimus, medius, and maximus. Two reconstructions were compared: (1) anatomic position of the acetabular center of rotation, and (2) cup medialization compensated by an increase in the femoral offset. Passive abduction-adduction and flexion-extension were simulated in the range of normal gait. Muscle moment arms were evaluated and correlated to preoperative femoral offset, acetabular offset, height of the greater trochanter (relative to femoral center of rotation), and femoral antetorsion angle. The increase of muscle moment arms caused by cup medialization varied among patients. Muscle moment arms increase by 10% to 85% of the amount of cup medialization for abduction-adduction and from -35% (decrease) to 50% for flexion-extension. The change in moment arm was inversely correlated (R(2) = 0.588, p = 0.001) to femoral antetorsion (anteversion), such that patients with less femoral antetorsion gained more in terms of hip muscle moments. No linear correlation was observed between changes in moment arm and

  8. Femoral artery recanalisation with percutaneous angioplasty and segmentally enclosed plasminogen activator

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Bülow, J

    1989-01-01

    To establish whether re-occlusion of the femoral artery could be prevented, in 6 consecutive patients undergoing percutaneous transluminal angioplasty (PTA) for superficial femoral artery occlusion the recanalised segment was isolated, with a 7-French double-balloon catheter. 5 mg recombined huma...

  9. Eu contributions to the ITER materials properties data assessment

    Energy Technology Data Exchange (ETDEWEB)

    Peacock, A.T. [EFDA CSU, Boltzmannstrasse 2, D-85748 Garching (Germany)]. E-mail: alan.peacock@tech.efda.org; Barabash, V. [IT, ITER Joint Work Site, Boltzmannstrasse 2, D-85748 Garching (Germany)]. E-mail: barabav@itereu.de; Gillemot, F. [ASI Consulting, Budafoki ut 21, H 2040 Budaors (Hungary)]. E-mail: gillemot@sunserv.kfki.hu; Karditsas, P. [EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon (United Kingdom)]. E-mail: Panos.Karditsas@ukaea.org.uk; Lloyd, G. [EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon (United Kingdom); Rensman, J.-W. [NRG Petten, Westerduinweg 3, P.O. Box 25, 1755 ZG Petten (Netherlands)]. E-mail: rensman@nrg-nl.com; Tavassoli, A.-A.F. [DMN/Dir, CEA/Saclay, CEA, 91191 Gif sur Yvette Cedex (France)]. E-mail: tavassoli@cea.fr; Walters, M. [EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon (United Kingdom)

    2005-11-15

    In order to fully organise the materials property data from the European next Fusion programme, a database of materials properties has been established. With the help of the database application and resulting data organisation, European materials experts have supported the recent activities within ITER aimed at updating and re-organising the ITER materials documentation. A European web based database application is described and its main features are detailed. In addition, we report on the details and the status of the work aimed at updating the ITER materials documentation. An outline of the future planned activities in the development of the European database and in the revision of the ITER materials documentation is also given.

  10. Material property changes of stainless steels under PWR irradiation

    International Nuclear Information System (INIS)

    Fukuya, Koji; Nishioka, Hiromasa; Fujii, Katsuhiko; Kamaya, Masayuki; Miura, Terumitsu; Torimaru, Tadahiko

    2009-01-01

    Structural integrity of core structural materials is one of the key issues for long and safe operation of pressurized water reactors. The stainless steel components are exposed to neutron irradiation and high-temperature water, which cause significant property changes and irradiation assisted stress corrosion cracking (IASCC) in some cases. Understanding of irradiation induced material property changes is essential to predict integrity of core components. In the present study, microstructure and microchemistry, mechanical properties, and IASCC behavior were examined in 316 stainless steels irradiated to 1 - 73 dpa in a PWR. Dose-dependent changes of dislocation loops and cavities, grain boundary segregation, tensile properties and fracture mode, deformation behavior, and their interrelation were discussed. Tensile properties and deformation behavior were well coincident with microstructural changes. IASCC susceptibility under slow strain rate tensile tests, IASCC initiation under constant load tests in simulated PWR primary water, and their relationship to material changes were discussed. (author)

  11. The stability of the femoral component of a minimal invasive total hip replacement system.

    NARCIS (Netherlands)

    Willems, M.M.M.; Kooloos, J.G.M.; Gibbons, P.; Minderhoud, N.; Weernink, T.; Verdonschot, N.J.J.

    2006-01-01

    In this study, the initial stability of the femoral component of a minimal invasive total hip replacement was biomechanically evaluated during simulated normal walking and chair rising. A 20 mm diameter canal was created in the femoral necks of five fresh frozen human cadaver bones and the femoral

  12. Comparative study on stiffness properties of WOODCAST and conventional casting materials.

    Science.gov (United States)

    Pirhonen, Eija; Pärssinen, Antti; Pelto, Mika

    2013-08-01

    Plaster-of-Paris and synthetic materials (e.g. fibreglass) have been in clinical use as casting materials for decades. An innovative casting material, WOODCAST, brings interesting alternatives to the traditional materials. The aim of this study was to compare the stiffness properties of the WOODCAST material to traditional casting materials. In immobilization by casting, materials with variable stiffness properties are required. Ring stiffness of cylindrical samples correlates well with cast rigidity. For load-bearing structures, the use of the WOODCAST Splint is recommended as equally high stiffness was obtained with the WOODCAST Splint as was with fibreglass. The WOODCAST 2 mm product is optimal for structures where some elasticity is required, and WOODCAST Ribbon can be used in any WOODCAST structure where further reinforcement is needed. The results show that WOODCAST material can be used in replacing traditional casting materials used in extremity immobilization. The mechanical properties of casting material play an important role in safe and effective fracture immobilization. Stiffness properties of the WOODCAST casting material and conventional materials - fibreglass and plaster-of-Paris - were analysed in this study. The WOODCAST Splint appears to compare favorably with traditional materials such as Scotchcast.

  13. Computer tomographic determination of femoral anteversion

    International Nuclear Information System (INIS)

    Jend, H.H.

    1986-01-01

    Thirty-two macerated femora were examined by CT in order to determine the degree of anteversion and to relate this to the position of the femur and to the various reference lines quoted in the literature. The accuracy of CT is the same as that of the Rippstein method, provided the following conditions are met: 1. Position of the femur with its long axis perpendicular to the image plane. 2. Demonstration of the maximal configuration of the femoral condyles to enable one to construct a tangent to the dorsal aspect of the condyle. 3. Demonstration of the head and neck by a plane which divides the neck into approximately equal portions and sections the femoral head. These conditions are more easily met, even in immobile patients, than the requirements for the Rippstein method. (orig.) [de

  14. Rotation of intramedullary alignment rods affects distal femoral cutting plane in total knee arthroplasty.

    Science.gov (United States)

    Maderbacher, Günther; Matussek, Jan; Keshmiri, Armin; Greimel, Felix; Baier, Clemens; Grifka, Joachim; Maderbacher, Hermann

    2018-02-17

    Intramedullary rods are widely used to align the distal femoral cut in total knee arthroplasty. We hypothesised that both coronal (varus/valgus) and sagittal (extension/flexion) cutting plane are affected by rotational changes of intramedullary femoral alignment guides. Distal femoral cuts using intramedullary alignment rods were simulated by means of a computer-aided engineering software in 4°, 6°, 8°, 10°, and 12° of valgus in relation to the femoral anatomical axis and 4° extension, neutral, as well as 4°, 8°, and 12° of flexion in relation to the femoral mechanical axis. This reflects the different angles between anatomical and mechanical axis in coronal and sagittal planes. To assess the influence of rotation of the alignment guide on the effective distal femoral cutting plane, all combinations were simulated with the rod gradually aligned from 40° of external to 40° of internal rotation. Rotational changes of the distal femoral alignment guides affect both the coronal and sagittal cutting planes. When alignment rods are intruded neutrally with regards to sagittal alignment, external rotation causes flexion, while internal rotation causes extension of the sagittal cutting plane. Simultaneously the coronal effect (valgus) decreases resulting in an increased varus of the cutting plane. However, when alignment rods are intruded in extension or flexion partly contradictory effects are observed. Generally the effect increases with the degree of valgus preset, rotation and flexion. As incorrect rotation of intramedullary alignment guides for distal femoral cuts causes significant cutting errors, exact rotational alignment is crucial. Coronal cutting errors in the distal femoral plane might result in overall leg malalignment, asymmetric extension gaps and subsequent sagittal cutting errors.

  15. Variant Branching of the Common Femoral Artery in a Black Kenyan ...

    African Journals Online (AJOL)

    Branching pattern of common femoral artery is important during artery catheterization, orthopaedic, plastic and general surgery in the proximal thigh. Frequency of variant branching shows ethnic variation but there are no data for black African populations. Since atherosclerotic diseases are increasing and femoral artery ...

  16. Analysis of hemodynamic characteristics in anastomotic sites of femoral artery implantation

    Energy Technology Data Exchange (ETDEWEB)

    Roh, H.W. [Graduate School, Soongsil University, Seoul (Korea); Suh, S.H. [SoongsSil University, Seoul (Korea); Yoo, S.S. [Hankuk Aviation University, Kyonggi-do (Korea); Kim, D.I.; Lee, B.B. [Samsung Medical Center (Korea)

    1998-11-01

    The objective of the present study is to obtain information on the hemodynamic characteristics in the anastomotic sites of femoral artery through the vascular implantation. Three dimensional steady and physiological blood flows in the femoral artery are simulated using the finite volume method. The geometrical shape of the anastomotic sites is made based on the vascular anatomy of a white rabbit. Wall shear stress distributions in the anastomotic sites for the physiological flow are compared with those for steady flow. Blood flow phenomena in the anastomotic sites of the femoral artery are discussed extensively. (author). 9 refs., 11 figs., 1 tab.

  17. The application of bilateral femoral vein approaches in interventional treatment of deep venous thrombosis of left lower extremity

    International Nuclear Information System (INIS)

    Wang Xiuping; Liu Jian; Wang Bin; Yao Zhongqiang; Zhang Yan; Li Chen

    2011-01-01

    Objective: To investigate the feasibility of interventional catheterization with bilateral femoral vein approaches for performing the thrombolytic treatment of acute deep venous thrombosis of left lower extremity. Methods: Antegrade puncturing into the left femoral vein was carried out in eighteen patients with acute deep vein thrombosis in the left lower extremity after left iliac-femoral vein catheterization via the right femoral vein or the right jugular vein access failed. When the puncturing of the left femoral vein was successfully done and was confirmed by angiography, the guide wire was inserted into the inferior vena cava and was pulled out through the right femoral vein or right jugular vein, and a wire track was thus established. Then, retrograde insertion of the catheter was conducted along the wire from the right to the left until the catheter was placed into the left iliac-femoral vein for thrombolysis. Results: Of 18 cases,successful puncturing into the left femoral vein was achieved in 16, and an effective wire track was established between the left and right femoral veins, based on which the catheter was smoothly inserted into the left iliac-femoral vein via the right femoral vein or jugular vein. Catheter thrombolysis was employed for 3 to 14 days, the thrombus was completely dissolved and the lower extremity swelling subsided. During the course of thrombolysis, no obvious congestion or hematoma occurred at the puncturing site of the left femoral vein. Conclusion: For patients with deep vein thrombosis of left lower extremity, when left iliac-femoral vein catheterization via the right femoral vein or the right jugular vein access failed, the establishment of wire track by using bilateral femoral vein approaches for further catheterization of left iliac-femoral vein and subsequent thrombolysis is feasible in clinical practice. This technique is safe and minimally-invasive with higher success rate. (authors)

  18. The application of PRP combined with TCP in repairing avascular necrosis of the femoral head after femoral neck fracture in rabbit.

    Science.gov (United States)

    Zhang, X-L; Wang, Y-M; Chu, K; Wang, Z-H; Liu, Y-H; Jiang, L-H; Chen, X; Zhou, Z-Y; Yin, G

    2018-02-01

    In view of the high occurrence of avascular necrosis of the femoral head (ANFH) after femoral neck fracture and the difficulties in the treatment, our work aimed to explore the effects of platelet-rich plasma (PRP) combined with tri-calcium phosphate (TCP) on the repair of ANFH after femoral neck fracture and to provide reference for clinical treatment. Thirty New Zealand white rabbits were randomly divided into control group, TCP group, and PRP+TCP group. The rabbit ANFH model was established and femoral head tissues were collected. HE staining was used for histological observation. Image analysis and statistical analysis were used to calculate the New Bone Area fraction (NBA %). The levels of bone morphogenetic protein (BMP)-7, transforming growth factor (TGF)-β1, basic fibroblast growth factor (bFGF), interleukin (IL)-6 and tumor necrosis factor (TNF)-a in serum were detected by Enzyme-Linked ImmunoSorbent Assay (ELISA). The new bone area of TCP group was significantly lower than that of PRP+TCP group (pPRP+TCP groups (pPRP+TCP group was higher than that in TCP group. TCP and PRP+TCP can both significantly reduce the content of IL-6 and TNF-a (pPRP+TCP group compared with the TCP group at 8 weeks after injection. PRP combined with TCP, which can promote new bone formation and inhibit inflammatory response, showed higher efficiency in repairing ANFH than internal fixation alone.

  19. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic cemented or... Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be implanted...

  20. Radiation-induced femoral head necrosis

    African Journals Online (AJOL)

    2011-03-25

    Mar 25, 2011 ... had open medial menisectomy of the left knee following medial meniscal tear ... postoperative recovery and mobilised full weight-bearing immediately [Figure 6]. ... obtained from the oncologists at the time of this review), and there was a ... previous trauma such as femoral neck fracture, Gaucher's disease ...

  1. Mechanical Properties of Nanostructured Materials Determined Through Molecular Modeling Techniques

    Science.gov (United States)

    Clancy, Thomas C.; Gates, Thomas S.

    2005-01-01

    The potential for gains in material properties over conventional materials has motivated an effort to develop novel nanostructured materials for aerospace applications. These novel materials typically consist of a polymer matrix reinforced with particles on the nanometer length scale. In this study, molecular modeling is used to construct fully atomistic models of a carbon nanotube embedded in an epoxy polymer matrix. Functionalization of the nanotube which consists of the introduction of direct chemical bonding between the polymer matrix and the nanotube, hence providing a load transfer mechanism, is systematically varied. The relative effectiveness of functionalization in a nanostructured material may depend on a variety of factors related to the details of the chemical bonding and the polymer structure at the nanotube-polymer interface. The objective of this modeling is to determine what influence the details of functionalization of the carbon nanotube with the polymer matrix has on the resulting mechanical properties. By considering a range of degree of functionalization, the structure-property relationships of these materials is examined and mechanical properties of these models are calculated using standard techniques.

  2. Tribological properties of silicate materials on nano and microscale

    International Nuclear Information System (INIS)

    Tordjeman, Ph.; Morel, N.; Ramonda, M.

    2009-01-01

    We studied the friction properties of four model silicate materials at the nanoscale and microscale. From nanotribology, we characterized the tribological properties at single asperity contact scale and from microtribology, we characterized the tribological properties at multi asperity contact scale. First, for each material we measured chemical composition by XPS, Young's modulus by acoustical microscopy and roughness σ by atomic force microscopy (AFM). Second, we measured the nanofriction coefficients with an AFM and the microfriction coefficients with a ball probe tribometer, for three hardnesses of the ball probe. We identified one friction mechanism at the nanoscale (sliding friction) and two friction mechanisms at the microscale (sliding friction and yielding friction). Comparison of the nano and microfriction coefficients at the same sliding friction regime shown, that the tribological properties of these materials didn't depend on roughness.

  3. Valsalva and gravitational variability of the internal jugular vein and common femoral vein: Ultrasound assessment

    Energy Technology Data Exchange (ETDEWEB)

    Beddy, P. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland)]. E-mail: pbeddy@eircom.net; Geoghegan, T. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Ramesh, N. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Buckley, O. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); O' Brien, J. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Colville, J. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Torreggiani, W.C. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland)

    2006-05-15

    Purpose: Central venous cannulation via the common femoral vein is an important starting point for many interventions. The purpose of this study was to determine the optimum conditions for cannulation of the femoral vein and to compare these with the relative changes in the internal jugular vein. Methods: High-resolution 2D ultrasound was utilised to determine variability of the calibre of the femoral and internal jugular veins in 10 healthy subjects. Venous diameter was assessed during the Valsalva manoeuvre and in different degrees of the Trendelenburg position. Results: The Valsalva manoeuvre significantly increased the size of the femoral and internal jugular veins. There was a relatively greater increase in femoral vein diameter when compared with the internal jugular vein of 40 and 29%, respectively. Changes in body inclination (Trendelenburg position) did not significantly alter the luminal diameter of the femoral vein. However, it significantly increased internal jugular vein diameter. Conclusions: Femoral vein cannulation is augmented by the Valsalva manoeuvre but not significantly altered by the gravitational position of the subject.

  4. Efficacy analysis of tomosynthesis in the diagnosis of the femoral head osteochondropathy (Legg-Calvé-Perthes disease

    Directory of Open Access Journals (Sweden)

    A. Yu. Vasil'ev

    2017-01-01

    Full Text Available Background: Despite the fact that the prevalence of the femoral head osteochondropathy is 2.9% of all bone and muscle disorders and 25% of the disorders of the hip joint, this problem demands special attention, while late diagnosis could lead to disability of the patient.Aim: To compare and clarify X-ray symptomatology of Legg-Calvé-Perthes disease found by standard digital radiography and by tomosynthesis.Materials and methods: Eighty six patients aged from 5 to 12 years with the femoral head osteochondropathy were allocated into two groups: 43  patients from the group  1 were assessed by standard two-plane digital radiography (frontal and Lauenstein projections, whereas 43  patients from the group  2 were assessed by direct plane tomosynthesis only. The investigations were performed with the X-ray machine FDR AcSelerate  200 (Fujifilm, Japan with the function of tomosynthesis. Radiographic symptoms of the disease were assessed in the subgroups that were identified depending on the disease stage: 24 patients had stage I, 20 – stage II, 20 – stage III, and 22 – stages IV and V.Results: Standard radiography could not detect any bone abnormalities in any patient with stage I of Legg-Calvé-Perthes disease (n1 = 12, 100%; however, by means of tomosynthesis, all patients from this subgroup (n2 = 12, 100% had minimally increased density on the affected side. In 9  (75% patients, tomosynthesis showed cystiform remodeling of trabecular structure in subchondral parts of the femoral head of the affected hip, and in 2 (17% patients, flattening of the inner epiphysis pole was visualized. At stage II of the disease standard radiography showed femoral head compression with widening of the joint space in 8 (80% patients, absence of subchondral lucency in 6 (60%, and increased density of the femoral head in 4 (40%. In all these patients (n2 = 10, 100% tomosynthesis showed signs of intra-articular effusion, in 6 (60% cases there were

  5. Multiplanar CT assessment of femoral head displacement in slipped capital femoral epiphysis

    Energy Technology Data Exchange (ETDEWEB)

    Monazzam, Shafagh [Rady Children' s Hospital and Health Center, Department of Orthopedics, San Diego, CA (United States); Dwek, Jerry R. [Rady Children' s Hospital and Health Center, Department of Radiology, San Diego, CA (United States); Hosalkar, Harish S. [Center for Hip Preservation, Department of Orthopedic Surgery, TriCity Medical Center, Oceanside, CA (United States)

    2013-12-15

    With recent changing approaches to the management of slipped capital femoral epiphysis (SCFE), the accurate radiographic assessment of maximum extent of displacement is crucial for planning surgical treatment. To determine what plane best represents the maximum SCFE displacement as quantified by the head-neck angle difference (HNAD), whether HNAD can quantitatively differentiate the SCFE cohort from the normal cohort, based on CT, and how Southwick slip angle (SSA) compares to HNAD. We reviewed 19 children with SCFE (23 affected hips) with preoperative CT scans and 27 age- and sex-matched children undergoing abdominal CT for non-orthopedic problems. Head-neck angle (HNA), the angle between the femoral epiphysis and the neck axis, was measured in three planes on each hip and the HNAD (affected - unaffected hip) was determined. SSA was measured on radiographs. The coronal HNAD (mean 8.7 ) was less than both the axial-oblique (mean 30.7 ) and sagittal (mean 37.4 ) HNADs, which were also greater than the HNADs of the normal cohort. Grouping HNAD measurements by SSA severity classification did not consistently distinguish between SCFE severity levels. Axial-oblique and sagittal planes best represent the maximum SCFE displacement while biplanar radiograph may underestimate the extent of the displacement, thereby potentially altering the management between in situ pinning and capital realignment. (orig.)

  6. Structural material properties for fusion application

    Energy Technology Data Exchange (ETDEWEB)

    Tavassoli, A-A. F.

    2008-10-15

    Materials properties requirements for structural applications in the forthcoming and future fusion machines are analyzed with emphasis on safety requirements. It is shown that type 316L(N) used in the main structural components of ITER is code qualified and together with limits imposed on its service conditions and neutron radiation levels, can adequately satisfy ITER vacuum vessel licensing requirements. For the in-vessel components, where nonconventional fabrication methods, such as HIPing, are used, design through materials properties, data is combined with tests on representative mockups to meet the requirements. For divertor parts, where the operating conditions are too severe for components to last throughout the reactor life, replacement of most exposed parts is envisaged. DEMO operating conditions require extension of ITER design criteria to high temperature and high neutron dose rules, as well as to compatibility with cooling and tritium breeding media, depending on the blanket concept retained. The structural material favoured in EU is Eurofer steel, low activation martensitic steel with good ductility and excellent resistance to radiation swelling. However, this material, like other ferritic / martensitic steels, requires post-weld annealing and is sensitive to low temperature irradiation embrittlement. Furthermore, it shows cyclic softening during fatigue, complicating design against fatigue and creep-fatigue. (au)

  7. Avascularity of the femoral head following intracapsular fracture: a comparative scintigraphic and bioptic study

    Energy Technology Data Exchange (ETDEWEB)

    Hoilund-Carlsen, P F; Widding, A; Uhrenholdt, A; Christoffersen, P; Grieff, J [Copenhagen Univ. (Denmark)

    1980-03-01

    Bioptic and scintigraphic methods of diagnosing avascular necrosis of the femoral head following intracapsular fracture of the femoral neck were compared. During operative treatment of patients, biospy samples of bone marrow were taken from the femoral head about 2 hours after the intravenous injection of sup(99m)Tc-Sn-pyrophosphate; histological examination of the biopsies were also performed. Scintigrams of the femoral head using sup(99m)Tc-pyrophosphate were performed 2 days, 7 days and 6 weeks post-operatively. The biopsies confirmed no morphological changes being apparent in the first few days. The biopsy samples indicated two groups of patients with either high or low activity in the femoral head. However, it was concluded that the use of bone-seeking radionuclides with this technique might be more reliable. Scintigraphic trends divided the patients into three groups, one with persistently normal, another with varying, and a third with decreased activity in the femoral head. It was concluded that very early scintigraphy is probably not the method of choice since the images were often difficult to interpret. For the present, assessment of the viability of the femoral head should rest upon scintigraphic examinations performed about 6 weeks or 3 months after the injury.

  8. Alterations of the blood pool in the femoral head before and after renal transplantation

    International Nuclear Information System (INIS)

    Hamaguchi, Hiroyuki; Fujioka, Mikihiro; Inoue, Shigehiro; Shibatani, Masahiko; Kubo, Toshikazu; Kubota, Takao; Ushijima, Yo; Nishimura, Tsunehiko

    2003-01-01

    The pathogenesis of idiopathic osteonecrosis of the femoral head (ION) is thought to be an ischemic event. The purpose of this study is to investigate alterations of the blood pool in the femoral head before and after renal transplantation. After renal transplantation, all patients received the same immunosuppressive therapy: corticosteroids, cyclosporin-A, and azathioprine. We performed 3-phase bone scintigraphy on 16 renal allograft recipients within 1 week before renal transplantation, and between week 4 and 9 after renal transplantation. Regions of interest (ROI) were assigned bilaterally in the femoral head, diaphysis, and soft tissue. The head-to-diaphysis ratios (HD ratios) were then calculated. Idiopathic osteonecrosis of the femoral head occurred in 2 femoral heads of 1 patient. The HD ratio before renal transplantation (mean HD±SD, 1.52±0.30) and the HD ratio after renal transplantation (1.28±0.30) were significantly different (P=0.000024). The HD ratios before and after renal transplantation were significantly different, indicating that the administration of steroids diminished the blood pool in the femoral head. A low HD ratio before renal transplantation revealed a poor blood pool in the femoral head, which may be a risk factor for ION. (author)

  9. Informatics derived materials databases for multifunctional properties

    International Nuclear Information System (INIS)

    Broderick, Scott; Rajan, Krishna

    2015-01-01

    In this review, we provide an overview of the development of quantitative structure–property relationships incorporating the impact of data uncertainty from small, limited knowledge data sets from which we rapidly develop new and larger databases. Unlike traditional database development, this informatics based approach is concurrent with the identification and discovery of the key metrics controlling structure–property relationships; and even more importantly we are now in a position to build materials databases based on design ‘intent’ and not just design parameters. This permits for example to establish materials databases that can be used for targeted multifunctional properties and not just one characteristic at a time as is presently done. This review provides a summary of the computational logic of building such virtual databases and gives some examples in the field of complex inorganic solids for scintillator applications. (review)

  10. Technique and results of femoral bifurcation endarterectomy by eversion.

    Science.gov (United States)

    Dufranc, Julie; Palcau, Laura; Heyndrickx, Maxime; Gouicem, Djelloul; Coffin, Olivier; Felisaz, Aurélien; Berger, Ludovic

    2015-03-01

    This study evaluated, in a contemporary prospective series, the safety and efficacy of femoral endarterectomy using the eversion technique and compared our results with results obtained in the literature for the standard endarterectomy with patch closure. Between 2010 and 2012, 121 patients (76% male; mean age, 68.7 years; diabetes, 28%; renal insufficiency, 20%) underwent 147 consecutive femoral bifurcation endarterectomies using the eversion technique, associating or not inflow or outflow concomitant revascularization. The indications were claudication in 89 procedures (60%) and critical limb ischemia in 58 (40%). Primary, primary assisted, and secondary patency of the femoral bifurcation, clinical improvement, limb salvage, and survival were assessed using Kaplan-Meier life-table analysis. Factors associated with those primary end-points were evaluated with univariate analysis. The technical success of eversion was of 93.2%. The 30-day mortality was 0%, and the complication rate was 8.2%; of which, half were local and benign. Median follow-up was 16 months (range, 1.6-31.2 months). Primary, primary assisted, and secondary patencies were, respectively, 93.2%, 97.2%, and 98.6% at 2 years. Primary, primary assisted, and secondary maintenance of clinical improvement were, respectively, 79.9%, 94.6%, and 98.6% at 2 years. The predictive factors for clinical degradation were clinical stage (Rutherford category 5 or 6, P = .024), platelet aggregation inhibitor treatment other than clopidogrel (P = .005), malnutrition (P = .025), and bad tibial runoff (P = .0016). A reintervention was necessary in 18.3% of limbs at 2 years: 2% involving femoral bifurcation, 6.1% inflow improvement, and 9.5% outflow improvement. The risk factors of reintervention were platelet aggregation inhibitor (other than clopidogrel, P = .049) and cancer (P = .011). Limb preservation at 2 years was 100% in the claudicant population. Limb salvage was 88.6% in the critical limb ischemia population

  11. Osteochondral lesion of the bilateral femoral heads in a young athletic patient

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Eun; Ryu, Kyung Nam; Park, Ji Seon; Cho, Yoon Je [Kyung Hee University Hospital, Seoul (Korea, Republic of); Yoon, So Hee; Park, So Young; Jin, Wook [Dept. of Radiology, Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Seoul (Korea, Republic of); Lee, Kyung Ryeol [Dept. of Radiology, Jeju National University Hospital, Jeju (Korea, Republic of)

    2014-12-15

    Osteochondral lesions of the femoral head are uncommon and few studies have reported their imaging findings. Since joints are at risk of early degeneration after osteochondral damage, timely recognition is important. Osteochondral lesions of femoral head may often be necessary to differentiate from avascular necrosis. Here, we report a case of osteochondral lesions on bilateral femoral heads. This lesion manifested as subchondral cysts in initial radiographs, which led to further evaluation by computed tomography arthrography and magnetic resonance imaging, which revealed overlying cartilage defects.

  12. Stochasticity in materials structure, properties, and processing—A review

    Science.gov (United States)

    Hull, Robert; Keblinski, Pawel; Lewis, Dan; Maniatty, Antoinette; Meunier, Vincent; Oberai, Assad A.; Picu, Catalin R.; Samuel, Johnson; Shephard, Mark S.; Tomozawa, Minoru; Vashishth, Deepak; Zhang, Shengbai

    2018-03-01

    We review the concept of stochasticity—i.e., unpredictable or uncontrolled fluctuations in structure, chemistry, or kinetic processes—in materials. We first define six broad classes of stochasticity: equilibrium (thermodynamic) fluctuations; structural/compositional fluctuations; kinetic fluctuations; frustration and degeneracy; imprecision in measurements; and stochasticity in modeling and simulation. In this review, we focus on the first four classes that are inherent to materials phenomena. We next develop a mathematical framework for describing materials stochasticity and then show how it can be broadly applied to these four materials-related stochastic classes. In subsequent sections, we describe structural and compositional fluctuations at small length scales that modify material properties and behavior at larger length scales; systems with engineered fluctuations, concentrating primarily on composite materials; systems in which stochasticity is developed through nucleation and kinetic phenomena; and configurations in which constraints in a given system prevent it from attaining its ground state and cause it to attain several, equally likely (degenerate) states. We next describe how stochasticity in these processes results in variations in physical properties and how these variations are then accentuated by—or amplify—stochasticity in processing and manufacturing procedures. In summary, the origins of materials stochasticity, the degree to which it can be predicted and/or controlled, and the possibility of using stochastic descriptions of materials structure, properties, and processing as a new degree of freedom in materials design are described.

  13. Material Property Correlations: Comparisons between FRAPCON-3.4, FRAPTRAN 1.4, and MATPRO

    Energy Technology Data Exchange (ETDEWEB)

    Luscher, Walter G.; Geelhood, Kenneth J.

    2010-08-01

    The U.S. Nuclear Regulatory Commission (NRC) uses the computer codes FRAPCON-3 and FRAPTRAN to model steady state and transient fuel behavior, respectively, in regulatory analysis. In order to effectively model fuel behavior, material property correlations must be used for a wide range of operating conditions (e.g. temperature and burnup). In this sense, a 'material property' is a physical characteristic of the material whose quantitative value is necessary in the analysis process. Further, the property may be used to compare the benefits of one material versus another. Generally speaking, the material properties of interest in regulatory analysis of nuclear fuel behavior are mechanical or thermodynamic in nature. The issue of what is and is not a 'material property' will never be universally resolved. In this report, properties such as thermal conductivity are included. Other characteristics of the material (e.g. fission gas release) are considered 'models' rather than properties, and are discussed elsewhere. Still others (e.g., neutron absorption cross-section) are simply not required in this specific analysis. The material property correlations for the FRAPCON-3 and FRAPTRAN computer codes were documented in NUREG/CR-6534 and NUREG/CR-6739, respectively. Some of these have been modified or updated since the original code documentation was published. The primary purpose of this report is to consolidate the current material property correlations used in FRAPCON-3 and FRAPTRAN into a single document. Material property correlations for oxide fuels, including uranium dioxide (UO2) and mixed oxide (MOX) fuels, are described in Section 2. Throughout this document, the term MOX will be used to describe fuels that are blends of uranium and plutonium oxides, (U,Pu)O2. The properties for uranium dioxide with other additives (e.g., gadolinia) are also discussed. Material property correlations for cladding materials and gases are described in

  14. Materials used to simulate physical properties of human skin.

    Science.gov (United States)

    Dąbrowska, A K; Rotaru, G-M; Derler, S; Spano, F; Camenzind, M; Annaheim, S; Stämpfli, R; Schmid, M; Rossi, R M

    2016-02-01

    For many applications in research, material development and testing, physical skin models are preferable to the use of human skin, because more reliable and reproducible results can be obtained. This article gives an overview of materials applied to model physical properties of human skin to encourage multidisciplinary approaches for more realistic testing and improved understanding of skin-material interactions. The literature databases Web of Science, PubMed and Google Scholar were searched using the terms 'skin model', 'skin phantom', 'skin equivalent', 'synthetic skin', 'skin substitute', 'artificial skin', 'skin replica', and 'skin model substrate.' Articles addressing material developments or measurements that include the replication of skin properties or behaviour were analysed. It was found that the most common materials used to simulate skin are liquid suspensions, gelatinous substances, elastomers, epoxy resins, metals and textiles. Nano- and micro-fillers can be incorporated in the skin models to tune their physical properties. While numerous physical skin models have been reported, most developments are research field-specific and based on trial-and-error methods. As the complexity of advanced measurement techniques increases, new interdisciplinary approaches are needed in future to achieve refined models which realistically simulate multiple properties of human skin. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Assessment of femoral head perfusion by dynamic MR imaging

    International Nuclear Information System (INIS)

    Ochi, Ryuya; Nakano, Tetsuo; Miyazono, Kazuki; Tsurugami, Hiroshi; Fukuda, Tomohiro; Inaba, Daisuke; Takada, Koji

    2004-01-01

    We studied femoral head perfusion in 21 femoral neck fractures using dynamic MR imaging (MRI) between November 2001 and July 2002. MRI patterns divided into four groups when the results between the fractured side and unaffected side were compared. Femoral head perfusion at the fractured side was normal in Type A, about half in Type B, and absent in Type C. When perfusion at both the fractured side and unaffected side was absent, Exceptional Type was suspected. The Garden I group consisted of one Type B. The Garden II group consisted of one Type A, six Type B, one Type C, and two Exceptional Type. The Garden III group consisted of two Type B and one Type C, and the Garden IV group consisted of six Type C and one Exceptional Type. Post operations of by internal fixation confirmed the incidence of aseptic necrosis using MRI. (author)

  16. Complications and Functional Recovery in Treatment of Femoral Shaft Fractures with Unreamed Intramedullary Nailing

    OpenAIRE

    Sadic, Sahmir; Custovic, Svemir; Smajic, Nedim; Fazlic, Mirsad; Vujadinovic, Aleksandar; Hrustic, Asmir; Jasarevic, Mahir

    2014-01-01

    ABSTRACT Introduction: Fracture of the femoral shaft is a common fracture encountered in orthopedic practice. In the 1939, K?ntscher introduced the concept of intramedullary nailing for stabilization of long bone fractures. Intramedullary nailing has revolutionized the treatment of fractures. Material and methods: The study included 37 male patients and 13 female patients, averaged 39?20,5 years (range, 16 to 76 years). Results and discussion: There were 31 left femurs and 21 right femurs fra...

  17. Static bending test after proximal femoral nail (PFN removal - in vitro analysis

    Directory of Open Access Journals (Sweden)

    Leonardo Morais Paiva

    Full Text Available Abstract Objective To evaluate, through biomechanical testing, the resistance to and energy required for the occurrence of proximal femoral fracture in synthetic bone after removal of a proximal femoral nail model (PFN, comparing the results obtained with a reinforcement technique using polymethylmethacrylate (PMMA. Methods Fifteen synthetic bones were used: five units for the control group (CG, five for the test group without reinforcement (TGNR, and five for the test group with reinforcement (TGR. The biomechanical analysis was performed simulating a fall on the trochanter using a servo-hydraulic machine. In the GC, the assay was performed with the PFN intact. In the TGNR and TGR groups, a model of PFN was introduced and the tests were performed in the TGNR, after simple removal of the synthesis material, and in the TGR, after removal of the same PFN model and filling of the cavity in the femoral neck with PMMA. Results All groups presented a basicervical fracture. The CG presented a mean of 1427.39 Newtons (N of maximum load and 10.14 Joules (J of energy for the occurrence of the fracture. The TGNR and TGR presented 892.14 N and 1477.80 N of maximum load, and 6.71 J and 11.99 J of energy, respectively. According to the Kruskal-Wallis ANOVA, there was a significant difference in the maximum load (p = 0.009 and energy (p = 0.007 between these groups. Conclusion The simple removal of a PFN in synthetic bone showed a significant reduction of the maximum load and energy for the occurrence of fracture, which were re-established with a reinforcement technique using PMMA.

  18. A Reference Guide for Cryogenic Properties of Materials

    Energy Technology Data Exchange (ETDEWEB)

    Weisend, John G

    2003-09-16

    A thorough knowledge of the behavior of materials at cryogenic temperatures is critical for the design of successful cryogenic systems. Over the past 50 years, a tremendous amount of material properties at cryogenic temperatures have been measured and published. This guide lists resources for finding these properties. It covers online databases, computer codes, conference proceedings, journals, handbooks, overviews and monographs. It includes references for finding reports issued by government laboratories and agencies. Most common solids and fluids used in cryogenics are covered.

  19. MYCOTIC FEMORAL PSEUDOANEURYSMS FROM INTRAVENOUS DRUG ABUSE

    Directory of Open Access Journals (Sweden)

    Vojko Flis

    2004-04-01

    Full Text Available Background. Parenteral drug abuse is the most common cause of infected femoral artery pseudoaneurysms (IFAP. This complication of intravenous drug abuse is not only limb threatening but can also be life threatening. The management of the IFAP is difficult and controversial. Generally speaking, ligation and excision of the pseudoaneurysm without revascularization is accepted procedure in majority of the patients. However it is not regarded as an appropriate procedure for cases where the high probability of amputation is expected from acute interruption of the femoral artery flow.Patients, methods and results. We present three cases of young (average 20 years, range 18–24 patients with IFAP, in which a primary reconstruction was performed due to absence of doppler signal over pedal arteries after ligation of common femoral artery. In two of them complications in form of haemorrhage and repeated infection developed in late postoperative period. The first one, had an excision and ligation while the second one had a reconstruction made by means of a silver impregnated dacron prosthesis. None of the patients required an amputation.Conclusions. Overall prognosis and prognosis of the reconstruction in parenteral drug abuse patients is uncertain because there is a high incidence of postoperative drug injection despite aggressive drug rehabilitation.

  20. Femoral anteversion assessment: Comparison of physical examination, gait analysis, and EOS biplanar radiography.

    Science.gov (United States)

    Westberry, David E; Wack, Linda I; Davis, Roy B; Hardin, James W

    2018-05-01

    Multiple measurement methods are available to assess transverse plane alignment of the lower extremity. This study was performed to determine the extent of correlation between femoral anteversion assessment using simultaneous biplanar radiographs and three-dimensional modeling (EOS imaging), clinical hip rotation by physical examination, and dynamic hip rotation assessed by gait analysis. Seventy-seven patients with cerebral palsy (GMFCS Level I and II) and 33 neurologically typical children with torsional abnormalities completed a comprehensive gait analysis with same day biplanar anterior-posterior and lateral radiographs and three-dimensional transverse plane assessment of femoral anteversion. Correlations were determined between physical exam of hip rotation, EOS imaging of femoral anteversion, and transverse plane hip kinematics for this retrospective review study. Linear regression analysis revealed a weak relationship between physical examination measures of hip rotation and biplanar radiographic assessment of femoral anteversion. Similarly, poor correlation was found between clinical evaluation of femoral anteversion and motion assessment of dynamic hip rotation. Correlations were better in neurologically typical children with torsional abnormalities compared to children with gait dysfunction secondary to cerebral palsy. Dynamic hip rotation cannot be predicted by physical examination measures of hip range of motion or from three-dimensional assessment of femoral anteversion derived from biplanar radiographs. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Titanium elastic nailing in pediatric femoral diaphyseal fractures

    Directory of Open Access Journals (Sweden)

    Singh Roop

    2006-01-01

    Full Text Available Background: The need for operative fixation of pediatric femoral fractures is increasingly being recognised in the present decade. The conventional traction and casting method for management of pediatric femoral fractures is giving way for the operative stabilisation of the fracture. Methods : Thirty five pediatric patients in age group 6-14 years with diaphyseal femoral fractures were stabilised with two titanium nails. Patients were followed up clinically and radiologically for two years. The final results were evaluated using the criteria of Flynn et al. Technical problems and complications associated with the procedure were also analysed. Results : Overall results observed were excellent in 25, satisfactory in 8 and poor in 2 patients. Hospital time averaged 12.30 days in the series. All the fractures healed with an average time to union of 9.6 (6-14.4 weeks. Return to school was early with an average of 7.8 weeks. The soft tissue discomfort near the knee produced by the nails ends was the most common problem encountered. Shortening was observed in three cases and restriction of knee flexion in 5 patients. There was no delayed union, infection or refractures. Per operative technical problems included failure of closed reduction in 2 cases and cork screwing of nails in one case. Conclusion : We believe that with proper operative technique and aftercare TENs may prove to be an ideal implant for pediatric femoral fracture fixation. The most of the complication associated with the procedure are infact features of inexact technique and can be eliminated by strictly adhering to the basic principles and technical aspects.

  2. Patency of Femoral Tunneled Hemodialysis Catheters and Factors Predictive of Patency Failure

    International Nuclear Information System (INIS)

    Burton, Kirsteen R.; Guo, Lancia L. Q.; Tan, Kong T.; Simons, Martin E.; Sniderman, Kenneth W.; Kachura, John R.; Beecroft, John R.; Rajan, Dheeraj K.

    2012-01-01

    Purpose: To determine the patency rates of and factors associated with increased risk of patency failure in patients with femoral vein tunneled hemodialysis catheters. Methods: All femoral tunneled catheter insertions from 1996 to 2006 were reviewed, during which time 123 catheters were inserted. Of these, 66 were exchanges. Patients with femoral catheter failure versus those with femoral catheter patency were compared. Confounding factors, such as demographic and procedural factors, were incorporated and assessed using univariate and multivariable Cox proportional hazards regression analyses. Results: Mean catheter primary patency failure time was 96.3 days (SE 17.9 days). Primary patency at 30, 60, 90, and 180 days was 53.8%, 45.4%, 32.1%, and 27.1% respectively. Crude rates of risk of catheter failure did not suggest a benefit for patients receiving catheters introduced from one side versus the other, but more cephalad location of catheter tip was associated with improved patency. Multivariate analysis showed that patients whose catheters were on the left side (p = 0.009), were of increasing age at the time of insertion (p = 0.002) and that those who had diabetes (p = 0.001) were at significantly greater risk of catheter failure. The catheter infection rate was 1.4/1000 catheter days. Conclusion: Patients who were of a more advanced age and had diabetes were at greater risk of femoral catheter failure, whereas those who received femoral catheters from the right side were less at risk of catheter failure.

  3. Drilling the femoral tunnel during ACL reconstruction: transtibial versus anteromedial portal techniques.

    Science.gov (United States)

    Tudisco, Cosimo; Bisicchia, Salvatore

    2012-08-01

    Incorrect bone tunnel position, particularly on the femoral side, is a frequent cause of failed anterior cruciate ligament reconstruction. Several studies have reported that drilling the femoral tunnel through the anteromedial portal allows a more anatomical placement on the lateral femoral condyle and higher knee stability than does transtibial reconstruction.In the current study, the femoral tunnel was drilled with transtibial (n=6) and anteromedial (n=6) portal techniques in 12 cadaveric knees. With appropriate landmarks inserted into bone tunnels, the direction and length of the tunnels were determined on anteroposterior and lateral radiographs. Knee stability was evaluated with a KT1000 arthrometer (MEDmetric Corporation, San Diego, California) and pivot shift test, comparing the pre- and postoperative values of both techniques. Finally, all knees were dissected to enhance vision of the insertion of the reconstructed ligament. The anteromedial portal technique led to better placement of the femoral tunnel in the coronal and sagittal planes, with higher knee stability according to the pivot shift test but not the KT1000 arthrometer. Anatomical and clinical results reported in the literature on transtibial and anteromedial portal techniques are controversial, but most of studies report better results with the anteromedial portal technique, especially regarding rotational stability. The current cadaveric study showed that the anteromedial portal technique provided better tunnel placement on the lateral femoral condyle in the coronal and sagittal planes, with an improvement in the rotational stability of the knee. Copyright 2012, SLACK Incorporated.

  4. Clinical application of interventional therapy for avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Han Xu; Jin Kesi; Liu Wei; Ma Jun; Shen Jianming; Aziken

    2004-01-01

    Objective: To evaluate the possibility of interventional therapy for avascular necrosis of the femoral head, with different curing methods, way of introduction and cultural heritages. Methods: Vasodilator, thrombolytics and promoting microcirculatory drug were directly injected into the feeding arteries of the avascular necrotic femoral heads, under the condition of applying the blood stoppage belt at the root of thigh with pressure before the drug injection into the femoral pronator and extension arteries. The treatment was repeated 45 d later. Urokinase 10 5 unite/d x 10 were administrated with venous infusion ipsilaterally on the 15th day after the beginning of the therapy. Imaging features and clinical symptoms were recorded and correlatively studied before and after the treament. Results: Symptoms relief especially the pain reached 100% after the treatment with various degrees of bony repair and new bone formation. Furthermore, increase caliber of feeding small arteries for femoral head and multiplicity of microvasculature, shortening of opacification time were revealed by DSA. IV stage bony change showed mild or inconspicuous. Conclusions: Interventional catheterization treatment for avascular femoral head necrosis, especially the patients of fore III stage, is safe and effective. (authors)

  5. Acquisition of material properties in production for sheet metal forming processes

    International Nuclear Information System (INIS)

    Heingärtner, Jörg; Hora, Pavel; Neumann, Anja; Hortig, Dirk; Rencki, Yasar

    2013-01-01

    In past work a measurement system for the in-line acquisition of material properties was developed at IVP. This system is based on the non-destructive eddy-current principle. Using this system, a 100% control of material properties of the processed material is possible. The system can be used for ferromagnetic materials like standard steels as well as paramagnetic materials like Aluminum and stainless steel. Used as an in-line measurement system, it can be configured as a stand-alone system to control material properties and sort out inapplicable material or as part of a control system of the forming process. In both cases, the acquired data can be used as input data for numerical simulations, e.g. stochastic simulations based on real world data

  6. [RESEARCH PROGRESS OF EXPERIMENTAL ANIMAL MODELS OF AVASCULAR NECROSIS OF FEMORAL HEAD].

    Science.gov (United States)

    Yu, Kaifu; Tan, Hongbo; Xu, Yongqing

    2015-12-01

    To summarize the current researches and progress on experimental animal models of avascular necrosis of the femoral head. Domestic and internation literature concerning experimental animal models of avascular necrosis of the femoral head was reviewed and analyzed. The methods to prepare the experimental animal models of avascular necrosis of the femoral head can be mainly concluded as traumatic methods (including surgical, physical, and chemical insult), and non-traumatic methods (including steroid, lipopolysaccharide, steroid combined with lipopolysaccharide, steroid combined with horse serum, etc). Each method has both merits and demerits, yet no ideal methods have been developed. There are many methods to prepare the experimental animal models of avascular necrosis of the femoral head, but proper model should be selected based on the aim of research. The establishment of ideal experimental animal models needs further research in future.

  7. Mortality Following Periprosthetic Proximal Femoral Fractures Versus Native Hip Fractures.

    Science.gov (United States)

    Boylan, Matthew R; Riesgo, Aldo M; Paulino, Carl B; Slover, James D; Zuckerman, Joseph D; Egol, Kenneth A

    2018-04-04

    The number of periprosthetic proximal femoral fractures is expected to increase with the increasing prevalence of hip arthroplasties. While native hip fractures have a well-known association with mortality, there are currently limited data on this outcome among the subset of patients with periprosthetic proximal femoral fractures. Using the New York Statewide Planning and Research Cooperative System, we identified patients from 60 to 99 years old who were admitted to a hospital in the state with a periprosthetic proximal femoral fracture (n = 1,655) or a native hip (femoral neck or intertrochanteric) fracture (n = 97,231) between 2006 and 2014. Within the periprosthetic fracture cohort, the indication for the existing implant was not available in the data set. We used mixed-effects regression models to compare mortality at 1 and 6 months and 1 year for periprosthetic compared with native hip fractures. The risk of mortality for patients who sustained a periprosthetic proximal femoral fracture was no different from that for patients who sustained a native hip fracture at 1 month after injury (3.2% versus 4.6%; odds ratio [OR], 0.90; 95% confidence interval [CI], 0.68 to 1.19; p = 0.446), but was lower at 6 months (3.8% versus 6.5%; OR, 0.74; 95% CI, 0.57 to 0.95; p = 0.020) and 1 year (9.7% versus 15.9%; OR, 0.71; 95% CI, 0.60 to 0.85; p accounting for age and comorbidities. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  8. Osteosynthesis of femoral neck fractures: dynamic hip screw (DHS or mini-invasive Targon FN system?

    Directory of Open Access Journals (Sweden)

    A. K. Dulaev

    2015-01-01

    Full Text Available Objectives: to investigate the long-term outcomes of femoral neck fractures that were surgically fixed using various types of extramedullary implants in patients aged 65 years and younger. Material and methods: We analyzed the clinical results of surgical treatment of femoral neck fractures by extramedullary osteosynthesis in 94 patients aged 38 to 65 years old (71 women and 23 men. The patients were divided into 3 groups according to AO/ASIF fracture classification. We used different techniques of osteosynthesis: with DHS or with Targon FN. In all patients the mental status rate SPMSQ, osteoporosis degree (Singh index, general somatic status (WHO scale were evaluated in the preoperative period. We also evaluated next intraoperative parameters: duration of surgery, blood loss, quality of reduction, long of incision. In a year after surgery we assessed functional results (Harris Hip Score and analysed postoperative complications. Results: It was found the inverse correlation (r = -0,8 of total preoperative parameters (WHO scale, the Singh index and mental status SPMSQ and postoperative functional results on Harris Hip Score. With the reliability of p<0.05 the average rate of blood loss and length of skin incision were less in patients operated with Targon FN. In 12 months unsatisfactory results rate on Harris Hip Score was 12.7% in all study groups, great - 22,3%, good - 52.1%, and satisfactory - 12,9%. Complications rate in patients operated with DHS was 17,02%, and in patients operated with Targon FN - 18.1%. Conclusion: Minimally invasive osteosynthesis of femoral neck fractures (type B1 and B2 on AO/ASIF classification allows to achieve the best results in compare with DHS osteosynthesis. Revealed complications such as screw migration, false joint formation and femoral head avascular necrosis were determined by impaired surgical technique and inadequate reduction.

  9. Avascular necrosis of the femoral head; Chronological change of MR images

    Energy Technology Data Exchange (ETDEWEB)

    Kokubo, Takeshi; Takatori, Yoshio; Kamogawa, Morihide; Nakamura, Toshitaka; Ninomiya, Setsuo; Yoshikawa, Kohki; Itai, Yuji; Iio, Masahiro; Mitamura, Tadayuki [Tokyo Univ. (Japan). Faculty of Medicine

    1990-04-01

    T1-weighted MR images of thirty-six hips in 25 patients with avascular necrosis of the femoral head were obtained two to five times during the course of 2 to 26 months. We investigated these MR images in the light of the chronological change and compared them with plain radiographs. MR images changes in 16 femoral head; in general, the abnormal low intensity area in the femoral head reduced in extent and the internal high intensity area became smaller of disappeared. Thirteen femoral heads among them became more flattened on plain radiographs in the same period. It is noted that four different zones are defined in the femoral head after bone necrosis takes place: the dead bone marrow, the dead marrow which still contains fat, the reactive interface and the hyperemic bone marrow. In T1-weighted MR images, the dead bone marrow, the reactive interface and the hyperemic bone marrow are demonstrated as low intensity area, while the dead marrow containing fat may remain high in intensity. On the basis of this knowledge of histopathology and MR images of this disease, we suggest that reduction of the abnormal low intensity area and disappearance of the internal high intensity area on MR images can be regarded as diminution of hyperemia in the living bone marrow and loss of fat in the dead bone marrow, respectively. (author).

  10. Repair of femoral trochanteric osteotomy in the dog

    International Nuclear Information System (INIS)

    Whitelock, R.G.; Dyce, J.; Houlton, J.E.F.

    1997-01-01

    The records and radiographs of 24 dogs that underwent femoral trochanteric osteotomy repair were reviewed. Osteotomy repair was performed with either a pin and tension band wire or a lag screw technique. Significant clinical complications associated with the osteotomy were identified in one dog (4 per cent) six weeks after surgery, although abnormal radiographic changes were evident in 15 dogs (62 per cent). The method of repair did not influence healing and there were comparable radiographic complication rates. It is concluded that femoral trochanteric osteotomy is not associated with significant clinical problems, despite a high incidence of abnormal radiographic findings

  11. Case of slipped capital femoral epiphysis following radiation

    Energy Technology Data Exchange (ETDEWEB)

    Terada, Hiroshi; Usui, Hiroshi; Nakamura, Yutaka; Chiba, Masahiro; Yamaji, Shushin; Oba, Yoshihiro

    1987-06-01

    A 12-year-old boy presented with pain of the right hip joint and claudication. At the age of 7 months, the patient had received prophylactic irradiation of 30 Gy to the pelvic area including lumbar vertebrae and bilateral hip joints following extirpation of the right undescended testicle for embryonal carcinoma. Roentgenograph showed slipped capial femoral epiphysis. A review of the literature suggests that bone growth and hormonal changes in the early stage of puberty are involved, in addition to radiation damaged epiphyseal cartilage, in the pathophysiologic mechanisms of radiation induced slipped capital femoral epiphysis. (Namekawa, K.).

  12. Comparison of anatomic vs. straight femoral stem design in total hip replacement - femoral canal fill in vivo.

    Science.gov (United States)

    de Boer, Friso A; Sariali, Elhadi

    2017-05-12

    The femoral canal fill between an anatomic and a straight prosthesis design in cementless total hip arthroplasty (THA) was compared. We hypothesised that the anatomic SPS stem has higher proximal fill and lesser distal fill than the straight stem. The femoral canal fill was measured on 3 months routine postoperative x-rays at 5 levels of the stem in 50 consecutive patients, aged 35-83 years, who underwent 56 THA procedures by a single surgeon in this hospital. 22 patients received a straight design Ceramconcept Global stem, 34 patients received an anatomic design Symbios SPS stem. Both anteroposterior (AP) and lateral x-rays were combined to suggest a 3-D measurement. On the AP x-rays, the canal fill was significantly higher using the anatomic design stem at the proximal measurement levels, and was significantly higher at the distal levels using the straight stem. With the AP and lateral x-rays combined, the canal fill at the proximal levels was also significantly higher in the anatomic groups, nonsignificantly lower at the central level and significantly lower at the distal levels. In THA surgery, achieving high fill at the metaphysis of the femur and less fill at the diaphysis has been suggested to result in satisfactory outcome and high stability of the prosthesis. This study demonstrated that, compared to straight stem design, an anatomically designed stem has a significantly higher metaphyseal femoral canal fill.

  13. Elastic properties of synthetic materials for soft tissue modeling

    International Nuclear Information System (INIS)

    Mansy, H A; Grahe, J R; Sandler, R H

    2008-01-01

    Mechanical models of soft tissue are useful for studying vibro-acoustic phenomena. They may be used for validating mathematical models and for testing new equipment and techniques. The objective of this study was to measure density and visco-elastic properties of synthetic materials that can be used to build such models. Samples of nine different materials were tested under dynamic (0.5 Hz) compressive loading conditions. The modulus of elasticity of the materials was varied, whenever possible, by adding a softener during manufacturing. The modulus was measured over a nine month period to quantify the effect of ageing and softener loss on material properties. Results showed that a wide range of the compression elasticity modulus (10 to 1400 kPa) and phase (3.5 0 -16.7 0 ) between stress and strain were possible. Some materials tended to exude softener over time, resulting in a weight loss and elastic properties change. While the weight loss under normal conditions was minimal in all materials (<3% over nine months), loss under accelerated weight-loss conditions can reach 59%. In the latter case an elasticity modulus increase of up to 500% was measured. Key advantages and limitations of candidate materials were identified and discussed

  14. Tribological and Wear Properties of Multi-Layered Materials

    Directory of Open Access Journals (Sweden)

    V. Bria

    2011-09-01

    Full Text Available The usage of fabrics as reinforcements in composites is spreading due to fabrics’ properties. The use of fabrics allows obtaining of sinuous surfaces, for instance, unlike the use of prepregs. Using fabrics as reinforcements it is also possible to obtain laminate-like materials having the same matrix in all their volume. In the case of pre-pregs usage always it is necessary to discuss about the bonding between individual plies. For this study eight materials were formed. The forming method consisted in placing the pre-polymer imbued fabric pieces into a mould to obtain plates of composites. Two types of fabric were used: one simple type of untwisted tows of carbon fibres and the second one simple type of alternated untwisted tows of carbon and aramide fibres. Both fabrics were prepared in order to ensure the matrix adherence. The polymer matrix is realised from epoxy system EPIPHEN RE 4020 / EPIPHEN DE 4020 filled with clay and talc in equal amounts of 5% (weight ratio. The use of clay and talc were meant to improve the thermal dimensional stability of final materials. Tribological properties of formed materials were studied using pin-on-disk method with steel disk and pins made of materials. Both orientation of reinforcement fibres relative to friction direction were taken into account. Results are encouraging further studies in order to identify the best solution of forming a multi-component material with more than one designable property.

  15. Postoperative hemoglobin level in patients with femoral neck fracture

    OpenAIRE

    Nagra, Navraj; van Popta, Dmitri; Whiteside, Sigrid; Holt, Edward

    2018-01-01

    Objective: The aim of this study was to analyze the changes of hemoglobin levels in patients undergoing fixation for femoral neck fracture.Methods: Peroperative hemoglobin levels of patients who underwent either dynamic hip screw (DHS) fixation (n=74; mean age: 80 years) or hip hemiarthroplasty (n=104; mean age: 84 years) for femoral neck fracture was monitored.Results: There was a statistically and clinically significant mean drop of 31.1 g/L between the preoperative (D0) and postoperative D...

  16. Characterization of the electromechanical properties of EAP materials

    Science.gov (United States)

    Bar-Cohen, Yoseph; Sherrita, Stewart; Bhattachary, Kaushik; Lih, Shyh-Shiuh

    2001-01-01

    Electroactive polymers (EAP) are an emerging class of actuation materials. Their large electrically induced strains (longitudinal or bending), low density, mechanical flexibility, and ease of processing offer advantages over traditional electroactive materials. However, before the capability of these materials can be exploited, their electrical and mechanical behavior must be properly quantified. Two general types of EAP can be identified. The first type is ionic EAP, which requires relatively low voltages (EAP and it involves electrostrictive and/or Maxwell stresses. This type of materials requires large electric fields (>100MV/m) to achieve longitudinal deformations at the range from 4 - 360%. Some of the difficulties in characterizing EAP include: nonlinear properties, large compliance (large mismatch with metal electrodes), nonhomogeneity resulting from processing, etc. To support the need for reliable data, the authors are developing characterization techniques to quantify the electroactive responses and material properties of EAP materials. The emphasis of the current study is on addressing electromechanical issues related to the ion-exchange type EAP also known as IPMC. The analysis, experiments and test results are discussed in this paper.

  17. Trombose aguda de aneurisma de artéria femoral isolado: relato de caso Acute thrombosis of isolated femoral artery aneurysm: case report

    Directory of Open Access Journals (Sweden)

    André Hideo Motoki

    2008-12-01

    Full Text Available Aneurismas de artéria femoral são raros, porém são o segundo tipo mais freqüente de aneurismas periféricos, sendo o aneurisma de artéria poplítea o mais comum. Normalmente, são de etiologia aterosclerótica. As complicações deste aneurisma são representadas por embolia, trombose e, mais raramente, a rotura. O objetivo deste trabalho é relatar um caso de um paciente com 59 anos, masculino, com queixa de dor súbita em membro inferior esquerdo associado à frialdade, palidez e ausência de pulsos. O ecocolordoppler evidenciou a presença de aneurisma trombosado da artéria femoral comum. O paciente foi submetido, com sucesso, à ressecção do aneurisma, com reconstrução do leito arterial.Common femoral artery aneurysms are rare; however, they are the second most frequent type of peripheral aneurysm, popliteal artery aneurysms being the most common. They usually have atherosclerotic ethiology. The complications of this aneurysm are thromboembolism and, more rarely, rupture. This article aimed at reporting the case of a 59-year-old male patient with complaint of sudden pain in his left leg associated with coldness, paleness and absence of pulses. Color Doppler ultrasound showed a thrombosed aneurysm of the common femoral artery. The patient was successfully submitted to aneurysm resection with reconstruction of the arterial bed.

  18. A Statistics-Based Material Property Analysis to Support TPS Characterization

    Science.gov (United States)

    Copeland, Sean R.; Cozmuta, Ioana; Alonso, Juan J.

    2012-01-01

    Accurate characterization of entry capsule heat shield material properties is a critical component in modeling and simulating Thermal Protection System (TPS) response in a prescribed aerothermal environment. The thermal decomposition of the TPS material during the pyrolysis and charring processes is poorly characterized and typically results in large uncertainties in material properties as inputs for ablation models. These material property uncertainties contribute to large design margins on flight systems and cloud re- construction efforts for data collected during flight and ground testing, making revision to existing models for entry systems more challenging. The analysis presented in this work quantifies how material property uncertainties propagate through an ablation model and guides an experimental test regimen aimed at reducing these uncertainties and characterizing the dependencies between properties in the virgin and charred states for a Phenolic Impregnated Carbon Ablator (PICA) based TPS. A sensitivity analysis identifies how the high-fidelity model behaves in the expected flight environment, while a Monte Carlo based uncertainty propagation strategy is used to quantify the expected spread in the in-depth temperature response of the TPS. An examination of how perturbations to the input probability density functions affect output temperature statistics is accomplished using a Kriging response surface of the high-fidelity model. Simulations are based on capsule configuration and aerothermal environments expected during the Mars Science Laboratory (MSL) entry sequence. We identify and rank primary sources of uncertainty from material properties in a flight-relevant environment, show the dependence on spatial orientation and in-depth location on those uncertainty contributors, and quantify how sensitive the expected results are.

  19. MOlecular MAterials Property Prediction Package (MOMAP) 1.0: a software package for predicting the luminescent properties and mobility of organic functional materials

    Science.gov (United States)

    Niu, Yingli; Li, Wenqiang; Peng, Qian; Geng, Hua; Yi, Yuanping; Wang, Linjun; Nan, Guangjun; Wang, Dong; Shuai, Zhigang

    2018-04-01

    MOlecular MAterials Property Prediction Package (MOMAP) is a software toolkit for molecular materials property prediction. It focuses on luminescent properties and charge mobility properties. This article contains a brief descriptive introduction of key features, theoretical models and algorithms of the software, together with examples that illustrate the performance. First, we present the theoretical models and algorithms for molecular luminescent properties calculation, which includes the excited-state radiative/non-radiative decay rate constant and the optical spectra. Then, a multi-scale simulation approach and its algorithm for the molecular charge mobility are described. This approach is based on hopping model and combines with Kinetic Monte Carlo and molecular dynamics simulations, and it is especially applicable for describing a large category of organic semiconductors, whose inter-molecular electronic coupling is much smaller than intra-molecular charge reorganisation energy.

  20. Beyond local effective material properties for metamaterials

    Science.gov (United States)

    Mnasri, K.; Khrabustovskyi, A.; Stohrer, C.; Plum, M.; Rockstuhl, C.

    2018-02-01

    To discuss the properties of metamaterials on physical grounds and to consider them in applications, effective material parameters are usually introduced and assigned to a given metamaterial. In most cases, only weak spatial dispersion is considered. It allows to assign local material properties, e.g., a permittivity and a permeability. However, this turned out to be insufficient. To solve this problem, we study here the effective properties of metamaterials with constitutive relations beyond a local response and take strong spatial dispersion into account. This research requires two contributions. First, bulk properties in terms of eigenmodes need to be studied. We particularly investigate the isofrequency surfaces of their dispersion relation are investigated and compared to those of an actual metamaterial. The significant improvement to effectively describe it provides evidence for the necessity to use nonlocal material laws in the effective description of metamaterials. Second, to be able to capitalize on such constitutive relations, also interface conditions need to be known. They are derived in this contribution for our form of the nonlocality using a generalized (weak) formulation of Maxwell's equations. Based on such interface conditions, Fresnel expressions are obtained that predict the amplitude of the reflected and transmitted plane wave upon illuminating a slab of such a nonlocal metamaterial. This all together offers the necessary means for the in-depth analysis of metamaterials characterized by strong spatial dispersion. The general formulation we choose here renders our approach applicable to a wide class of metamaterials.

  1. Femoral arteriographic finding in acute ergotism: Report of A Case

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, H S; Lee, K N; Cha, S B [St. Mary' s Hospital, Catholic Medical College, Seoul (Korea, Republic of)

    1971-10-15

    A case of acute ergotism with angiographic demonstration of bilateral femoral artery involvement is reported. A 27-year-old married woman was admitted because of sudden onset of severe pain in both flanks and lower legs, followed by numbness and coldness of the skin on both legs. The attack occurred after the administration of ergot tartrate as postpartum care. Femoral arteriography was performed on 10th day of illness with the Seldinger technic. The femoral arteries were generally smaller in caliber than normal. There was no definite evidence of occlusive disease. Findings were more or less symmetrical and extended to lower legs where only fine branches were visualized. The final diagnosis was diffuse vasospasm due to acute ergotism with secondary occlusion of the arteries of lower leg bilaterally.

  2. Femoral arteriographic finding in acute ergotism: Report of A Case

    International Nuclear Information System (INIS)

    Rhee, H. S.; Lee, K. N.; Cha, S. B.

    1971-01-01

    A case of acute ergotism with angiographic demonstration of bilateral femoral artery involvement is reported. A 27-year-old married woman was admitted because of sudden onset of severe pain in both flanks and lower legs, followed by numbness and coldness of the skin on both legs. The attack occurred after the administration of ergot tartrate as postpartum care. Femoral arteriography was performed on 10th day of illness with the Seldinger technic. The femoral arteries were generally smaller in caliber than normal. There was no definite evidence of occlusive disease. Findings were more or less symmetrical and extended to lower legs where only fine branches were visualized. The final diagnosis was diffuse vasospasm due to acute ergotism with secondary occlusion of the arteries of lower leg bilaterally

  3. AGC 2 Irradiated Material Properties Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Rohrbaugh, David Thomas [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-05-01

    The Advanced Reactor Technologies Graphite Research and Development Program is conducting an extensive graphite irradiation experiment to provide data for licensing of a high temperature reactor (HTR) design. In past applications, graphite has been used effectively as a structural and moderator material in both research and commercial high temperature gas cooled reactor designs. , Nuclear graphite H 451, used previously in the United States for nuclear reactor graphite components, is no longer available. New nuclear graphite grades have been developed and are considered suitable candidates for new HTR reactor designs. To support the design and licensing of HTR core components within a commercial reactor, a complete properties database must be developed for these current grades of graphite. Quantitative data on in service material performance are required for the physical, mechanical, and thermal properties of each graphite grade, with a specific emphasis on data accounting for the life limiting effects of irradiation creep on key physical properties of the HTR candidate graphite grades. Further details on the research and development activities and associated rationale required to qualify nuclear grade graphite for use within the HTR are documented in the graphite technology research and development plan.

  4. Characterisation and properties of alkali activated pozzolanic materials

    Science.gov (United States)

    Bordeian, Georgeta Simona

    Many of the waste materials produced from modem heavy industries are pozzalans, which develop cementitious properties when finely divided in the presence of free lime. This property allows a potential industrial use for this waste as a cement replacement material in concrete. An example of such a waste material is blast furnace slag from the smelting of iron and steel. The US produces 26 million tons of blast furnace slag annually. Most of the slag is slowly cooled in air and it makes a poor pozzolan. Only 1.6 million tons of the slag is available in the granulated form, which is suitable as a cementitious and pozzolanic admixture. Most European countries are well endowed with coal-fired power stations and this produces fly and bottom ash, flue gas desulphurisation (FGD) gypsum. However, less than 25% of the total ash from power stations has found an industrial use mainly in cement and concrete industry. This creates a massive waste-disposal problem. Disposal of unused fly ash in open tips and ponds, for example, creates pollution problems since the drainage of effluents from the ash in the deposit ponds threaten water supplies by polluting the ground water with traces of toxic chemicals.Recent research has concentrated on the alkali activation of waste pozzolanic materials, especially ground blast furnace slag. This thesis has investigated the alkali activation of low calcium fly ashes. These form very poor pozzolans and the alkali activation of the fly ash offers the opportunity for the large scale use of fly ash. Water glass was selected as a suitable activator for the fly ash. A comprehensive series of tests have been carried out to gain information on the effect of different parameters, such as proportion and composition of the constituent materials, curing conditions and casting methods, in developing high performance construction materials. Laboratory investigations were carried out to determine the following characteristics of alkali activated materials

  5. Metal-ceramic materials. Study and prediction of effective mechanical properties

    International Nuclear Information System (INIS)

    Karakulov, Valerii V.; Smolin, Igor Yu.

    2016-01-01

    Mechanical behavior of stochastic metal-ceramic composite materials was numerically simulated on mesoscopic scale level. Deformation of mesoscopic volumes of composites, whose structure consists of a metal matrix and randomly distributed ceramic inclusions, was numerically simulated. The results of the numerical simulation were used for evaluation of the effective elastic and strength properties of metal-ceramic materials with different parameters of the structure. The values of the effective mechanical properties of investigated materials were obtained, and the character of the dependence of the effective elastic and strength properties on the structure parameters of composites was determined.

  6. Postoperative hemoglobin level in patients with femoral neck fracture.

    Science.gov (United States)

    Nagra, Navraj S; Van Popta, Dmitri; Whiteside, Sigrid; Holt, Edward M

    2016-01-01

    The aim of this study was to analyze the changes of hemoglobin levels in patients undergoing fixation for femoral neck fracture. Peroperative hemoglobin levels of patients who underwent either dynamic hip screw (DHS) fixation (n=74; mean age: 80 years) or hip hemiarthroplasty (n=104; mean age: 84 years) for femoral neck fracture was monitored. There was a statistically and clinically significant mean drop of 31.1 g/L between the preoperative (D0) and postoperative Day 5 Hb levels (pmeasurement, DHS patients had lower hemoglobin values over hemiarthroplasty patients (p=0.046). The decrease in hemoglobin in the first 24-hour postoperative period (D0 to Day 1) is an underestimation of the ultimate lowest value in hemoglobin found at Day 2. Relying on the Day 1 hemoglobin level could be detrimental to patient care. We propose a method of predicting patients likely to be transfused and recommend a protocol for patients undergoing femoral neck fracture surgery to standardize postoperative hemoglobin monitoring.

  7. Does femoral offset recover and affect the functional outcome of patients with displaced femoral neck fracture following hemiarthroplasty?

    Science.gov (United States)

    Ji, Hyung-Min; Won, Seok-Hyung; Han, Jun; Won, Ye-Yeon

    2017-06-01

    Restoring preoperative horizontal femoral offset (FO) promised good functional outcome in patients receiving total hip arthroplasty. However, relatively little was known regarding the clinical relevance of restoring the offset in patients with bipolar hemiarthroplasty to treat displaced femoral neck fracture. Therefore, the objective of this study was to evaluate postoperative FO accurately and verify its relation with functional outcome. One hundred elderly patients who received bipolar hemiarthroplasty to treat displaced femoral neck fracture were identified. Preoperative CT scanning of contralateral hip joint and reconstruction of images led to rotation-free FO. By referencing postoperative implant specification and comparing to measured values in Picture Archive and Communication System, rotation-free postoperative FO and the amount of change were acquired. Postoperative Harris Hip Score (HHS) and Modified Barthel Index (MBI) were evaluated to measure functional outcome at 12-month after the surgery. Patients with significant FO change were identified. Multiple regression analysis was conducted to determine if the FO change might independently affect the outcome regardless of confounding factors. The mean preoperative offset was 37.4±2.5 increased by 12.7±9.6% after the surgery. Only 25.0% of postoperative offset after hemiarthroplasty was changed within ±5% of preoperative offset. A total of 45.0% of postoperative offset changed within ±10% while 77.0% of postoperative offset changed within ±20%. 23% of patients whose FO changed more than 20% showed significantly worse outcome score than the patients whose FO change remained within ±20% of initial value. Mean MBI and HHS were negatively correlated with FO change. After adjusting for confounding factors, significant correlation remained between modification of FO and MBI, but not between FO change and HHS (B=4.576; β=0.235; 95% confidence interval of B: 0.534 to 8.135). FO was not properly restored in 23

  8. Management of osteonecrosis of the femoral head: A novel technique

    Directory of Open Access Journals (Sweden)

    Ahmed M Samy

    2016-01-01

    Full Text Available Background: Osteonecrosis of the femoral head (ONFH is a debilitating disease in orthopedics, frequently progressing to femoral head collapse and osteoarthritis. It is thought to be a multifactorial disease. ONFH ultimately results in femoral head collapse in 75-85% of untreated patients. Total hip arthroplasty (THA yields satisfactory results in the treatment of the end stage of the disease. However, disease typically affects males between the ages of 20 and 40 years and joint replacement is not the ideal option for younger patients. Recently, mesenchymal stem cells and platelet rich plasma (PRP have been used as an adjunct to core decompression to improve clinical success in the treatment of precollapse hips. Materials and Methods: A prospective study of 40 hips in 30 patients was done. There were 19 males and 11 females with a mean age 36.7 ± 6.93 years. The indication for the operation was restricted primarily to modified Ficat stages IIb and III. 16 hips (40% had stage IIb and 24 hips (60% had stage III ONFH. The period of follow up ranged between 36-50 months with a mean 41.4 ± 3.53 months. All patients were assessed clinically during pre- and post-operative period according to the Harris Hip Score (HHS, Visual Analog Score (VAS and radiologically by X-rays. Magnetic resonance imaging (MRI was done preoperatively to confirm the diagnosis and every 6 months postoperatively for assessment of healing. The operative procedure include removal of necrotic area with drilling then the cavity was filled with a composite of bone graft mixed with PRP. Results: The mean HHS improved from 46.0 ± 7.8 preoperatively to 90.28 ± 19 at the end of followup ( P < 0.0001. The mean values of VAS were 78 ± 21 and 35 ± 19 at preoperatively period and final followup, respectively, with an average reduction of 43 points. Conclusion: We found that the use of PRP with collagen sheet can increase the reparable capacity after drilling of necrotic segment in stage

  9. Significance of tests and properties of concrete and concrete-making materials

    CERN Document Server

    Pielert, James H

    2006-01-01

    Reflects a decade of technological changes in concrete industry! The newest edition of this popular ASTM publication reflects the latest technology in concrete and concrete-making materials. Six sections cover: (1) General information on the nature of concrete, sampling, variability, and testing laboratories. A new chapter deals with modeling cement and concrete properties. (2) Properties of freshly mixed concrete. (3) Properties of hardened concrete. (4) Concrete aggregates—this section has been revised and the chapters are presented in the order that most concerns concrete users: grading, density, soundness, degradation resistance, petrographic examination, reactivity, and thermal properties. (5) Materials other than aggregates—the chapter on curing materials now reflects the current technology of materials applied to new concrete surfaces. The chapter on mineral admixtures has been separated into two chapters: supplementary cementitious materials and ground slag. (6) Specialized concretes—contains a ...

  10. Nontraumatic femoral head necrosis. Classification of bone scintigraphic findings and diagnostic value of SPECT following planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Minoshima, Satoshi; Uchida, Yoshitaka; Anzai, Yoshimi; Uno, Kimiichi; Arimizu, Noboru [Chiba Univ. (Japan). School of Medicine

    1994-09-01

    This study was conducted to determine bone scintigraphic findings in nontraumatic femoral head avascular necrosis and diagnostic value of SPECT imaging following a conventional planar imaging. Forty-three femoral heads in twenty-six cases with idiopathic femoral head necrosis (n=2), systemic lupus erythematosus (n=22), aplastic anemia (n=1), and renal transplantation (n=1) were studied. The diagnosis for femoral head necrosis was based on magnetic resonance imaging as well as other diagnostic studies in all cases. Scintigraphic findings of planar and SPECT images were classified into six categories: normal (N); cold or decrease (C); partial increase with cold or decrease (PH+C); ring-like increase with a cold center (RH+C); partial increase (PH); diffuse and/or irregular increase (DH). Avascular necrosis was confirmed in twenty-four femoral heads, in which planar and SPECT images showed scintigraphic findings of N (n=3, 2), C (n=1, 3), PH+C (n=2, 8), RH+C (n=2, 3), PH (n=9, 2), and DH (n=7, 6), respectively. Femoral heads without avascular necrosis demonstrated planar and SPECT findings of N (n=16, 12), C (n=0, 6), and DH (n=3, 1), respectively. When considering C, PH+C, and RH+C as diagnostic findings for avascular necrosis, sensitivities of planar and SPECT images were 21% and 58%, and specificities were 100% and 68%, respectively. In nineteen femoral heads with normal planar findings (N), SPECT correctly identified avascular necrosis in two femoral heads and misidentified six normal femoral heads as avascular necrosis. In nineteen femoral heads with nondiagnostic abnormalities (PH, DH), SPECT correctly identified avascular necrosis in seven femoral heads and showed no false positive. Diagnostic planar findings in five femoral heads were concordant with SPECT diagnosis. These results indicate that SPECT imaging is most valuable when planar images show nondiagnostic abnormalities based on the proposed classification of scintigraphic findings. (author).

  11. Nontraumatic femoral head necrosis. Classification of bone scintigraphic findings and diagnostic value of SPECT following planar imaging

    International Nuclear Information System (INIS)

    Minoshima, Satoshi; Uchida, Yoshitaka; Anzai, Yoshimi; Uno, Kimiichi; Arimizu, Noboru

    1994-01-01

    This study was conducted to determine bone scintigraphic findings in nontraumatic femoral head avascular necrosis and diagnostic value of SPECT imaging following a conventional planar imaging. Forty-three femoral heads in twenty-six cases with idiopathic femoral head necrosis (n=2), systemic lupus erythematosus (n=22), aplastic anemia (n=1), and renal transplantation (n=1) were studied. The diagnosis for femoral head necrosis was based on magnetic resonance imaging as well as other diagnostic studies in all cases. Scintigraphic findings of planar and SPECT images were classified into six categories: normal (N); cold or decrease (C); partial increase with cold or decrease (PH+C); ring-like increase with a cold center (RH+C); partial increase (PH); diffuse and/or irregular increase (DH). Avascular necrosis was confirmed in twenty-four femoral heads, in which planar and SPECT images showed scintigraphic findings of N (n=3, 2), C (n=1, 3), PH+C (n=2, 8), RH+C (n=2, 3), PH (n=9, 2), and DH (n=7, 6), respectively. Femoral heads without avascular necrosis demonstrated planar and SPECT findings of N (n=16, 12), C (n=0, 6), and DH (n=3, 1), respectively. When considering C, PH+C, and RH+C as diagnostic findings for avascular necrosis, sensitivities of planar and SPECT images were 21% and 58%, and specificities were 100% and 68%, respectively. In nineteen femoral heads with normal planar findings (N), SPECT correctly identified avascular necrosis in two femoral heads and misidentified six normal femoral heads as avascular necrosis. In nineteen femoral heads with nondiagnostic abnormalities (PH, DH), SPECT correctly identified avascular necrosis in seven femoral heads and showed no false positive. Diagnostic planar findings in five femoral heads were concordant with SPECT diagnosis. These results indicate that SPECT imaging is most valuable when planar images show nondiagnostic abnormalities based on the proposed classification of scintigraphic findings. (author)

  12. Research on technology of evaluating thermal property data of nuclear power materials

    International Nuclear Information System (INIS)

    Imai, Hidetaka; Baba, Tetsuya; Matsumoto, Tsuyoshi; Kishimoto, Isao; Taketoshi, Naoyuki; Arai, Teruo

    1997-01-01

    For the materials of first wall and diverter of nuclear fusion reactor, in order to withstand steady and unsteady high heat flux load, excellent thermal characteristics are required. It is strongly demanded to measure such thermal property values as heat conductivity, heat diffusivity, specific heat capacity, emissivity and so using small test pieces up to higher than 2000degC. As the materials of nuclear reactors are subjected to neutron irradiation, in order to secure the long term reliability of the materials, it is very important to establish the techniques for forecasting the change of the thermal property values due to irradiation effect. Also the establishment of the techniques for estimating the thermal property values of new materials like low radioactivation material is important. In National Research Laboratory of Metrology, the research on the advancement of the measuring technology for high temperature thermal properties has resulted in the considerably successful development of such technologies. In this research, the rapid measurement of thermal property values up to superhigh temperature with highest accuracy, the making of thermal property data set of high level, the analysis and evaluation of the correlation of material characters and thermal property values, and the development of the basic techniques for estimating the thermal property values of solid materials are aimed at and advanced. These are explained. (K.I.)

  13. Arterial Ligation for Infected Femoral Psuedo-Aneurysm in Drug Injecting Abusers

    Directory of Open Access Journals (Sweden)

    Mohammadzade Mohammad Ali

    2009-10-01

    Full Text Available Pseudo-aneurysm of the femoral artery is the most common arterial complication in drug injecting abusers. Scholars in vascular surgery have published debating statements regarding techniques of successful surgical management during last two decades. We present the results of simple arterial ligation in a series of 32 patients presenting with infected femoral pseudo-aneurysm. Most of the patients were males (89%. Young persons in the age group of 15-44 years were mostly affected. Site of lesion included common femoral artery in 65% , superficial femoral artery 28% and at bifurcation 6.2%. celulitis in 14 (53%, abscess & "ncelulitis in 6 (19%, necrosing fasciitis in 2 (6.2% and vascular abscess in 7 (22% cases were the forms of associated local infection. There was no hemorrhage, vascular thrombosis, amputation, or mortality. Claudicating were the only complications identified in 2 patients with Tripe ligation. Ligation is the optimal management for infected pseudo-aneurysms because it is easy, cost-effective, and safe. Early reconstruction is not recommended, since there is an extended infection in the location of the pseudo-aneurysm.

  14. Magnetic resonance imaging (MRI) of avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Kokubo, Takashi; Yoshikawa, Kohki; Aoki, Shigeki

    1987-01-01

    Thirty-seven patients with the clinical diagnosis of or suspicious of avascular necrosis (AN) of the femoral head were examined by magnetic resonance imaging (MRI). In all patients with AN confirmed from clinical symptoms, past history and plain radiographs, MRI demonstrated abnormal low intensity area in the necrosed femoral head. The abnormal findings on MRI were divided into three patterns: low signal intensity occupying the greater part of the femoral head (type A), low signal intensity localized in the periphery (type B), ring-shaped or band-like low signal intensity (type C). No correlation was found among MRI patterns, radiographic findings and radionuclide bone scan images, except that the type C was not found in the stage IV determined radiographically. In the patients suspicious of AN, the positive rate of MRI was higher than that of radionuclide scan. Abnormal findings on only MRI may not necessarily indicate AN. However, such a patient must be kept under observation, because the possibility exists that only MRI detects early or asymptomatic AN of the femoral head. (author)

  15. Magnetic resonance imaging (MRI) of avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Kokubo, Takashi; Yoshikawa, Kohki; Aoki, Shigeki

    1987-05-01

    Thirty-seven patients with the clinical diagnosis of or suspicious of avascular necrosis (AN) of the femoral head were examined by magnetic resonance imaging (MRI). In all patients with AN confirmed from clinical symptoms, past history and plain radiographs, MRI demonstrated abnormal low intensity area in the necrosed femoral head. The abnormal findings on MRI were divided into three patterns: low signal intensity occupying the greater part of the femoral head (type A), low signal intensity localized in the periphery (type B), ring-shaped or band-like low signal intensity (type C). No correlation was found among MRI patterns, radiographic findings and radionuclide bone scan images, except that the type C was not found in the stage IV determined radiographically. In the patients suspicious of AN, the positive rate of MRI was higher than that of radionuclide scan. Abnormal findings on only MRI may not necessarily indicate AN. However, such a patient must be kept under observation, because the possibility exists that only MRI detects early or asymptomatic AN of the femoral head.

  16. Fracture of the acetabulum with femoral artery injury presenting late: A case report

    Directory of Open Access Journals (Sweden)

    Sivaprasad Kalyanasundaram

    2016-02-01

    Full Text Available This study reports a rare case of both column acetabulum fracture with femoral artery injury that presented late and was managed with arterial reconstruction and fracture fixation.A thirty-one year old man sustained both column acetabular fracture on the left in a motor vehicle accident. On admission there was no obvious neuro-vascular deficit. During surgery for the fracture after 7 days of the injury the femoral artery was found to be severely crushed with no blood flow. The anterior column of the acetabulum was stabilised followed by resection and reconstruction of the femoral artery. The post-operative period was uneventful and he was discharged normally. At 6 months from injury the fractures had united well with excellent limb circulation and good lower limb function.Femoral artery injury with acetabular fracture is rare and late presentations are unreported hitherto. The results of fracture stabilisation and vessel reconstruction seem to be excellent. Literature of similar injuries is reviewed. Keywords: Acetabular fractures, Both column fractures, Anterior column fractures, Vascular injury, Femoral artery injury

  17. Determination of material properties for short fibre reinforced C/C-SiC

    Directory of Open Access Journals (Sweden)

    Hausherr J.-M.

    2015-01-01

    Full Text Available Determining the mechanical properties of short fibre reinforced CMC using standard sized coupons has always been a challenge due to a high statistical scattering of the measured values. Although the random orientation of short fibres results in a quasi-isotropic material behavior of 2D-structures with a sufficiently large volume, the small volume typical for test coupons usually results in a non-isotropic fibre orientation in the tested volume. This paper describes a method for manufacturing unidirectional oriented short fibre reinforced CMC materials and presents material properties of UD-C/C-SiC. After verifying the fibre orientation of the CMC using micro-computed tomography, coupons were extracted to determine the orthotropic material properties. These orthotropic material properties were then used to predict the properties of C/C-SiC with randomly distributed short fibres. To validate the method, micro-computed tomography is used to quantitatively determine the fibre orientation within coupons extracted from randomly distributed short fibre C/C-SiC. After mechanical three-point-bending tests, the measured stiffness and bending strength is compared with the predicted properties. Finally, the data are used to devise a method suited for reducing the inherent large spread of material properties associated with the measurement of CMC materials with randomly distributed short fibres.

  18. Femoral neck pseudoarthrosis in a polio patient treated with closed reduction and cell therapy

    Directory of Open Access Journals (Sweden)

    M.A. Codesido

    2017-04-01

    Full Text Available Poliomyelitis disease affects the anterior horns cells of the spinal cord and certain motor nuclei of the brain stem. Paralysis type is flaccid and asymmetrical and result in muscular imbalance.Due to this, in case of having a hip muscles involvement, degenerative or posttraumatic, total hip arthroplasty is normally contraindicated because of the excessive risk of hip dislocation. In cases of subcapital femoral neck fractures the femoral head vascularization is a main concern, and in cases of neglected fracture with pseudoarthrosis the vascular status to the head must be investigated prior to further decisions.We report the case of a femoral neck fracture non-union after a missed femoral neck fracture in a polio affected leg treated with cannulated screws and percutaneous autologous injection of processed total nuclear cells (TNC mixed with putty demineralized bone matrix. Keywords: Pseudoarthrosis, Poliomyelitis, Cell therapy, Femoral neck

  19. Thermal Expansion Properties of Aerospace Materials

    Science.gov (United States)

    Green, E. F.

    1969-01-01

    Thermal expansion properties of materials used in aerospace systems are compiled into a single handbook. The data, derived from experimental measurements supplemented by information from literature sources, are presented in charts and tables arranged in two sections, covering cryogenic and elevated temperatures.

  20. Adjustment of Part Properties for an Elastomeric Laser Sintering Material

    Science.gov (United States)

    Wegner, A.; Ünlü, T.

    2018-03-01

    Laser sintering of polymers is gaining more and more importance within the field of small series productions. Polyamide 12 is predominantly used, although a variety of other materials are also available for the laser sintering process. For example, elastomeric, rubberlike materials offer very different part property profiles. Those make the production of flexible parts like, e.g., sealings, flexible tubes or shoe soles possible because they offer high part ductility and low hardness. At the chair for manufacturing technology, a new elastomeric laser sintering material has been developed and then commercialized by a spin-off from university. The aim of the presented study was the analysis of the new material's properties. Proof was found that Shore hardness can be modified by varying the parameter settings. Therefore, the correlation between process parameters, energy input, Shore hardness and other part properties like mechanical properties were analyzed. Based on these results, suitable parameter settings were established which lead to the possibility of producing parts with different Shore hardnesses.

  1. Threading the Needle: Intrapelvic Displacement of a Femoral Neck Fracture through the Obturator Foramen

    Directory of Open Access Journals (Sweden)

    Gautham Prabhakar

    2018-01-01

    Full Text Available Despite timely and appropriate management, displaced femoral neck fractures are often devastating injuries for the young patient. The risk of negative sequelae is further amplified with increasing displacement and vertical fracture patterns. Open anatomic reduction with rigid internal fixation is essential to maximize the healing potential in displaced fractures of the femoral neck. Successful primary osteosynthesis of significantly displaced femoral neck fractures in the young patient has been reported in the literature. We present a unique case of open reduction and internal fixation of a high-energy femoral neck fracture with extrusion of the head through the obturator foramen into the pelvis without associated acetabular or pelvic injury.

  2. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metal/polymer... § 888.3390 Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis is a two-part...

  3. 21 CFR 888.3380 - Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) trunnion-bearing... Devices § 888.3380 Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis is a two...

  4. Morfología femoral proximal en fracturas de cadera

    OpenAIRE

    Calvo de Mora Rebollo, María Jesús; Albareda Albareda, Jorge Cruz; Seral García, Belén; Martín Ruiz, G.; Lasierra Sanromán, José Manuel; Seral Iñigo, Fernando

    2003-01-01

    Es frecuente observar como pacientes que han sufrido una fractura de cadera, si se fracturan posteriormente la cadera contralateral, es del mismo tipo que la primera fractura. El objetivo de este trabajo es tratar de relacional la morfología femoral proximal con la producción de un tipo determinado de fractura. Para ello hemos realizado un estudio prospectivo en 50 pacientes mayores de 65 años, sin distinción de sexo, que han ingresado en nuestro servicio por fractura femoral proximal, 25 ...

  5. Synthesis, Properties and Mineralogy of Important Inorganic Materials

    CERN Document Server

    Warner, Terence E

    2010-01-01

    Intended as a textbook for courses involving preparative solid-state chemistry, this book offers clear and detailed descriptions on how to prepare a selection of inorganic materials that exhibit important optical, magnetic and electrical properties, on a laboratory scale. The text covers a wide range of preparative methods and can be read as separate, independent chapters or as a unified coherent body of work. Discussions of various chemical systems reveal how the properties of a material can often be influenced by modifications to the preparative procedure, and vice versa. References to miner

  6. Recent Advances in the Sound Insulation Properties of Bio-based Materials

    Directory of Open Access Journals (Sweden)

    Xiaodong Zhu

    2013-12-01

    Full Text Available Many bio-based materials, which have lower environmental impact than traditional synthetic materials, show good sound absorbing and sound insulation performances. This review highlights progress in sound transmission properties of bio-based materials and provides a comprehensive account of various multiporous bio-based materials and multilayered structures used in sound absorption and insulation products. Furthermore, principal models of sound transmission are discussed in order to aid in an understanding of sound transmission properties of bio-based materials. In addition, the review presents discussions on the composite structure optimization and future research in using co-extruded wood plastic composite for sound insulation control. This review contributes to the body of knowledge on the sound transmission properties of bio-based materials, provides a better understanding of the models of some multiporous bio-based materials and multilayered structures, and contributes to the wider adoption of bio-based materials as sound absorbers.

  7. Opalescence and fluorescence properties of indirect and direct resin materials.

    Science.gov (United States)

    Song, Sang-Hoon; Yu, Bin; Ahn, Jin-Soo; Lee, Yong-Keun

    2008-08-01

    To measure the opalescence and fluorescence properties of indirect and direct resin materials before and after polymerization, and to determine the influence of the material and shade group combination on these properties. BelleGlass NG (BG, indirect resin) and Estelite Sigma (ES, direct resin), each composed in 3 shade groups (EN, OD and TL for BG; BS, AS and OP for ES) out of a total of 16 shades were investigated. Resin material was packed into a mold (the BEC condition) and polymerized with a light-polymerization unit (CWL). Secondary polymerization (CIC) was performed for BG. Color was measured in the BEC, CWL, and CIC conditions, and the opalescence parameter (OP) and fluorescence parameter (FL) were calculated. For the OP, the mean for BG material was 24.3 before polymerization, which changed to 19.9 after polymerization (CIC). In the case of ES, the mean OP before polymerization was 25.6, which changed to 12.4 after polymerization (CWL). For the FL, the mean FL for BG was 2.5 before polymerization, which changed to 0.7 after polymerization. In the case of ES, the mean FL before polymerization was 1.2, which did not change after polymerization. Material and shade group combination influenced the OP and FL values (popalescence and fluorescence properties of resin materials varied depending on the material, shade group, and polymerization. Clinically, these properties should be considered when neighboring teeth are restored with different types of material.

  8. Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening

    Directory of Open Access Journals (Sweden)

    Ashvin Thambyah

    2014-01-01

    Full Text Available Previous gait studies on squatting have described a rapid reversal in the direction of the tibiofemoral joint shear reaction force when going into a full weight-bearing deep knee flexion squat. The effects of such a shear reversal have not been considered with regard to the loading demand on knee implants in patients whose activities of daily living require frequent squatting. In this paper, the shear reversal effect is discussed and simulated in a finite element knee implant-bone model, to evaluate the possible biomechanical significance of this effect on femoral component loosening of high flexion implants as reported in the literature. The analysis shows that one of the effects of the shear reversal was a switch between large compressive and large tensile principal strains, from knee extension to flexion, respectively, in the region of the anterior flange of the femoral component. Together with the known material limits of cement and bone, this large mismatch in strains as a function of knee position provides new insight into how and why knee implants may fail in patients who perform frequent squatting.

  9. Recruitment order of quadriceps motor units: femoral nerve vs. direct quadriceps stimulation.

    Science.gov (United States)

    Rodriguez-Falces, Javier; Place, Nicolas

    2013-12-01

    To investigate potential differences in the recruitment order of motor units (MUs) in the quadriceps femoris when electrical stimulation is applied over the quadriceps belly versus the femoral nerve. M-waves and mechanical twitches were evoked using femoral nerve stimulation and direct quadriceps stimulation of gradually increasing intensity from 20 young, healthy subjects. Recruitment order was investigated by analysing the time-to-peak twitch and the time interval from the stimulus artefact to the M-wave positive peak (M-wave latency) for the vastus medialis (VM) and vastus lateralis (VL) muscles. During femoral nerve stimulation, time-to-peak twitch and M-wave latency decreased consistently (P  0.05). For the VM muscle, M-wave latency decreased with increasing stimulation level for both femoral nerve and direct quadriceps stimulation, whereas, for the VL muscle, the variation of M-wave latency with stimulus intensity was different for the two stimulation geometries (P recruitment order during direct quadriceps stimulation was more complex, depending ultimately on the architecture of the peripheral nerve and its terminal branches below the stimulating electrodes for each muscle. For the VM, MUs were orderly recruited for both stimulation geometries, whereas, for the VL muscle, MUs were orderly recruited for femoral nerve stimulation, but followed no particular order for direct quadriceps stimulation.

  10. Prevention of excessive postoperative sliding of the short femoral nail in femoral trochanteric fractures.

    Science.gov (United States)

    Ito, Juji; Takakubo, Yuya; Sasaki, Kan; Sasaki, Junya; Owashi, Kazuya; Takagi, Michiaki

    2015-05-01

    Lag screw cut-out is one of the major postoperative complications on femoral trochanteric fractures. However, precise analyses of excessive sliding and lag screw cut-out were limited. The purpose of this study was to investigate the factors that induce this unfavorable event. From April 2010 to April 2013, 226 patients were operated in our institute using a short femoral nail. Among them, 177 patients (29 males and 148 females) with a mean age of 84 years (60-97 years), who were followed up >3 months, were included in this study. The postoperative sliding distance, fracture type (AO/OTA classification), tip-apex distance (TAD), reduction pattern in the postoperative X-ray (antero-posterior and lateral views), bone quality (canal flare and cortical indices), walking ability at the time of pre-injury and final follow-up, and complications were investigated retrospectively. The mean sliding distance was 3.7 mm, and one cut-out case (0.6 %) was observed. The sliding distance of the AO/OTA 31-A2 fractures was significantly longer than that of the A1 fractures (p fractures, an accurate reduction in the lateral view at surgery is important, particularly in unstable fractures.

  11. The surgical treatment of ilio-femoral venous obstruction.

    Science.gov (United States)

    Illuminati, G; Caliò, F G; D'Urso, A; Mancini, P; Papaspyropoulos, V; Ceccanei, G; Lorusso, R; Vietri, F

    2004-01-01

    A series of 9 patients of a mean age of 48 years, operated on for compression of the ilio-femoral venous axis is reported. The cause of obstruction was external compression in 3 cases, a retroperitoneal sarcoma in 1 case, and an infrarenal aortic aneurysm in 2. Two patients presented with a Cockett's syndrome, 3 with a chronic ilio-femoral thrombosis, and one with a post-traumatic segmentary stenosis. Treatment consisted in a resection/Dacron grafting of 2 infrarenal aortic aneurysms, one femoro-caval bypass graft, 2 transpositions of the right common iliac artery in the left hypogastric artery for Cockett's syndrome, 3 Palma's operations for chronic thrombosis, and one internal jugular vein interposition for segmentary stenosis. There were no postoperative deaths and no early thromboses of venous reconstructions performed. All the patients were relieved of symptoms during the follow-up period, whose mean length was 38 months. The cause of venous obstruction and the presence of symptoms which are resistant to medical treatment are the main indications to ilio-femoral venous revascularization. The choice of the optimal treatment in each single case yields satisfactory results.

  12. MR imaging of avascular femoral head necrosis - pre- and postoperative studies

    International Nuclear Information System (INIS)

    Schedel, H.; Ziegler, L.; Vogl, T.; Hilbertz, T.; Lissner, J.; Buchner, H.

    1992-01-01

    46 patients with avascular necrosis of the femoral head were examined by T 2 - and T 1 -weighted MR before and after infusion of Gd-DTPA. Both sides were involved in 12 cases. The classification was done according to Ficat. In early stages and in postoperative studies a correlation of signal intensity after infusion of Gd-DTPA and clinical symptoms was found. Hyperintensity of the avascular area or of the implanted material was assumed to be vascularised or vital components in 4 cases of Ficat 1 and 15 postoperative studies. Contrariwise, we found in 5 patients with severe postoperative symptoms, low signal intensity areas due to avascular regions. (orig.) [de

  13. MR imaging findings of the femoral marrow in myelodysplastic syndrome

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Takagi, Shojiro; Matsuura, Katsuhiko; Ichikawa, Tamaki; Kobayashi, Yasuyuki; Nagai, Jun

    1995-01-01

    MR imaging of the femoral marrow was performed in 30 patients with myelodysplastic syndrome (MDS), 11 cases of which evolved to acute myeloid leukemia (AML). The MRI appearance was classified into five patterns: fatty marrow; faint signal; nodular pattern; heterogeneous infiltration; and diffuse infiltration. For each type of MDS, MRI patterns of the femoral marrow were evaluated and compared with those in normal subjects as well as in patients with aplastic anemia. Signal intensity alteration, a low signal on T1-weighted SE image and a high signal on STIR image, began in the proximal femoral marrow almost symmetrically in patients with MDS. The area of abnormal signal intensity tended to gradually extend towards the distal portion of the femur as the disease progressed. MRI patterns of the femoral marrow correlated with marrow cellularity, and diffuse marrow infiltration was noted in patients with a more advanced type of MDS or with severe anemia. There were limitations to making an accurate diagnosis of the MDS type on the basis of the MRI pattern. Progression of the MRI appearance in the course of MDS was thought to be a sign suggesting evolution to AML. It was difficult to differentiate hypoplastic MDS from aplastic anemia, although the nodular pattern was commonly seen in the latter disease. (author)

  14. MR imaging findings of the femoral marrow in myelodysplastic syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Osamu; Takagi, Shojiro; Matsuura, Katsuhiko; Ichikawa, Tamaki; Kobayashi, Yasuyuki; Nagai, Jun [Jichi Medical School, Minamikawachi, Tochigi (Japan)

    1995-10-01

    MR imaging of the femoral marrow was performed in 30 patients with myelodysplastic syndrome (MDS), 11 cases of which evolved to acute myeloid leukemia (AML). The MRI appearance was classified into five patterns: fatty marrow; faint signal; nodular pattern; heterogeneous infiltration; and diffuse infiltration. For each type of MDS, MRI patterns of the femoral marrow were evaluated and compared with those in normal subjects as well as in patients with aplastic anemia. Signal intensity alteration, a low signal on T1-weighted SE image and a high signal on STIR image, began in the proximal femoral marrow almost symmetrically in patients with MDS. The area of abnormal signal intensity tended to gradually extend towards the distal portion of the femur as the disease progressed. MRI patterns of the femoral marrow correlated with marrow cellularity, and diffuse marrow infiltration was noted in patients with a more advanced type of MDS or with severe anemia. There were limitations to making an accurate diagnosis of the MDS type on the basis of the MRI pattern. Progression of the MRI appearance in the course of MDS was thought to be a sign suggesting evolution to AML. It was difficult to differentiate hypoplastic MDS from aplastic anemia, although the nodular pattern was commonly seen in the latter disease. (author).

  15. Radionuclide scintimetry for diagnosis of complications following femoral neck fracture

    International Nuclear Information System (INIS)

    Alberts, K.A.; Dahlborn, M.; Hindmarsh, J.; Soederborg, B.; Ringertz, H.

    1984-01-01

    A scintimetric study using Tc-99m MDP was made of 54 patients with delayed union, nonunion, or late segmental collapse of the femoral head, 4-92 months after femoral neck fracture. In radiographically verified collapse, the radionuclide uptake ratio between the femoral head on the fractured and on the intact side (HHR) was significantly higher than in fractures resulting in delayed union or nonunion. On the basis of scintimetric and radiographic findings, the patients with healing disturbances could be divided into three groups, characterized by the following features: (1) Satisfactory post-reduction position of the fracture without subsequent redisplacement and a high HHR, which as a rule turned out to be delayed union; (2) The same radiographic pattern but with a lower HHR, which in most cases resulted in nonunion; (3) Inadequate reduction or early redisplacement of the fracture with a high HHR, which resulted in nonunion. The fractional precision in discriminating between different types of disturbed fracture healing by means of skeletal scintimetry was 0.86 in this study. This non-invasive and technically simple method would therefore be a valuable complement to radiography in the assessment of healing, more than 4 months after fracture of the femoral neck. (author)

  16. Cellular and Porous Materials Thermal Properties Simulation and Prediction

    CERN Document Server

    Öchsner, Andreas; de Lemos, Marcelo J S

    2008-01-01

    Providing the reader with a solid understanding of the fundamentals as well as an awareness of recent advances in properties and applications of cellular and porous materials, this handbook and ready reference covers all important analytical and numerical methods for characterizing and predicting thermal properties. In so doing it directly addresses the special characteristics of foam-like and hole-riddled materials, combining theoretical and experimental aspects for characterization purposes.

  17. Mechanical Properties of Air Plasma Sprayed Environmental Barrier Coating (EBC) Materials

    Science.gov (United States)

    Richards, Bradley; Zhu, Dongming; Ghosn, Louis; Wadley, Haydn

    2015-01-01

    Development work in Environmental Barrier Coatings (EBCs) for Ceramic Matrix Composites (CMCs) has focused considerably on the identification of materials systems and coating architectures to meet application needs. The evolution of these systems has occurred so quickly that modeling efforts and requisite data for modeling lag considerably behind development. Materials property data exists for many systems in the bulk form, but the effects of deposition on the critical properties of strength and fracture behavior are not well studied. We have plasma sprayed bulk samples of baseline EBC materials (silicon, ytterbium disilicate) and tested the mechanical properties of these materials to elicit differences in strength and toughness. We have also endeavored to assess the mixed-mode fracture resistance, Gc, of silicon in a baseline EBC applied to SiCSiC CMC via four point bend test. These results are compared to previously determined properties of the comparable bulk material.

  18. Some functional properties of composite material based on scrap tires

    Science.gov (United States)

    Plesuma, Renate; Malers, Laimonis

    2013-09-01

    The utilization of scrap tires still obtains a remarkable importance from the aspect of unloading the environment from non-degradable waste [1]. One of the most prospective ways for scrap tires reuse is a production of composite materials [2] This research must be considered as a continuation of previous investigations [3, 4]. It is devoted to the clarification of some functional properties, which are considered important for the view of practical applications, of the composite material. Some functional properties of the material were investigated, for instance, the compressive stress at different extent of deformation of sample (till 67% of initial thickness) (LVS EN 826) [5] and the resistance to UV radiation (modified method based on LVS EN 14836) [6]. Experiments were realized on the purposefully selected samples. The results were evaluated in the correlation with potential changes of Shore C hardness (Shore scale, ISO 7619-1, ISO 868) [7, 8]. The results showed noticeable resistance of the composite material against the mechanical influence and ultraviolet (UV) radiation. The correlation with the composition of the material, activity of binder, definite technological parameters, and the conditions supported during the production, were determined. It was estimated that selected properties and characteristics of the material are strongly dependent from the composition and technological parameters used in production of the composite material, and from the size of rubber crumb. Obtained results show possibility to attain desirable changes in the composite material properties by changing both the composition and technological parameters of examined material.

  19. Starclose SE® hemostasis after 6F direct antegrade superficial femoral artery access distal to the femoral head for peripheral endovascular procedures in obese patients.

    Science.gov (United States)

    Spiliopoulos, Stavros; Kitrou, Panagiotis; Christeas, Nikolaos; Karnabatidis, Dimitris

    2016-01-01

    Direct superficial femoral artery (SFA) antegrade puncture is a valid alternative to common femoral artery (CFA) access for peripheral vascular interventions. Data investigating vascular closure device (VCD) hemostasis of distant SFA 6F access are limited. We aimed to investigate the safety and effectiveness of the Starclose SE® VCD for hemostasis, following direct 6F antegrade SFA access distal to the femoral head. This prospective, single-center study included patients who were not suitable for CFA puncture and were scheduled to undergo peripheral endovascular interventions using direct antegrade SFA 6F access, at least 2 cm below the inferior edge of femoral head. Hemostasis was obtained with the Starclose SE® VCD (Abbott Laboratories). Primary endpoints were successful hemostasis rate and periprocedural (30-day) major complication rate. Secondary endpoint was the rate of minor complications. Clinical and Doppler ultrasound follow-up was performed at discharge and at one month. Between September 2014 and August 2015, a total of 30 patients (21 male; 70.0%) with a mean body mass index of 41.2 kg/m2 were enrolled. Mean age was 72±9 years (range, 67-88 years). Most patients suffered from critical limb ischemia (87.1%) and diabetes (61.3%). Calcifications were present in eight cases (26.6%). Reason for direct SFA puncture was obesity (100%). Successful hemostasis was achieved in 100% of the cases. No major complications were noted after one-month follow-up. Minor complications included two <5 cm hematomas (6.6%) not necessitating treatment. In this prospective study, Starclose SE® VCD was safe and effective for hemostasis of antegrade direct SFA puncture. Uncomplicated hemostasis was achieved even in cases of puncturing 2 to 7 cm below the inferior edge of the femoral head.

  20. ediatric femoral shaft fractures treated by flexible intramedullary nailing.

    Science.gov (United States)

    Kapil Mani, K C; Dirgha Raj, R C; Parimal, Acharya

    2015-01-01

    Nowadays pediatric femoral fractures are more commonly managed with operative treatment rather than conservative treatment because of more rapid recovery and avoidance of prolonged immobilization. Children between the ages of 5-13 years are treated either by traction plus hip spica and flexible/elastic stable retrograde intramedullary nail, or external fixators in the case of open fractures. The aim of this study is to evaluate the outcome of pediatric femoral shaft fractures treated by stainless steel flexible intramedullary nail in children between 5 and 13 years of age. There were 32 cases of femoral shaft fractures which were all fixed with stainless steel flexible intramedullary nail under fluoroscopy. Long leg cast was applied at the time of fixation. Partial weight bearing was started 2 weeks after surgery. Patients were evaluated in follow-up study to observe the alignment of fracture, infection, delayed union, nonunion, limb length discrepancy, motion of knee joint, and time to unite the fracture. We were able to follow up 28 out of 32 patients. The patients were 8.14 years of age on average. The mean hospital stay after operation was 4 days and fracture union time was 9.57 weeks. There were 3 cases of varus angulation, 2 cases of anterior angulation, and 4 cases of limb lengthening. Patients aged between 5 and 13 years treated with flexible intramedullary nail for closed femoral shaft fracture have rapid union and recovery, short rehabilitation period, less immobilization and psychological impact, and cost-effective.

  1. Corticosteroid Reduces Blood Flow to Femoral Heads in Rabbits.

    Science.gov (United States)

    Hou, S.M.; Liu, T.K.; Kao, M.C.

    1994-12-01

    Avascular necrosis of the femoral head is one of the common problems in orthopedic practice in Taiwan. The subchondral bone loses its blood supply which weakens its biomechanical support. Steroid overuse is one of many possible etiologies in reducing blood flow to the femoral head. Laser Doppler velocimeter is a precise monitor of regional blood flow of bone which is expressed in perfusion units (PU). In the control group the rabbits were injected with normal saline and there were no statistical differences between blood flow to the right hip (39.26 +/- 5.64 PU) and left hip (38.58 +/- 4.35 PU). In group B a weekly injection of methylprednisolone into rabbits for 6 weeks demonstrated the reduction of blood flow of femoral head (24.74 +/- 3.13 PU) by the laser Doppler velocimeter. The flow decreased further (15.93 +/- 2.33 PU) by 12 weeks of steroid treatment. In group C after a weekly injection of steroid for 6 weeks the flow became 31.63 +/- 4.79 PU. The steroid was then discontinued for 3 weeks and the flow was 34.6 +/- 1.34 PU. In group D the blood flow was 25.89 +/- 4.01 PU after 6 weeks of steroid treatment and we stopped the steroid for 6 weeks, the blood flow became 29.86 +/- 2.59 PU. The merit of our experiment established a model of study in avascular necrosis of the femoral head in rabbits. Copyright 1994 S. Karger AG, Basel

  2. Femoral Hernia At Mulago Hospital, Uganda

    African Journals Online (AJOL)

    user

    2004-12-02

    Dec 2, 2004 ... consecutive patients operated for femoral hernia over a period of twelve months. Results: There were ... The age ranged from 42 years to 70 years old with a mean of 54.6 years old. All the .... cholecystectomy. At this point in ...

  3. Ultrasound-guided approach for axillary brachial plexus, femoral nerve, and sciatic nerve blocks in dogs.

    Science.gov (United States)

    Campoy, Luis; Bezuidenhout, Abraham J; Gleed, Robin D; Martin-Flores, Manuel; Raw, Robert M; Santare, Carrie L; Jay, Ariane R; Wang, Annie L

    2010-03-01

    To describe an ultrasound-guided technique and the anatomical basis for three clinically useful nerve blocks in dogs. Prospective experimental trial. Four hound-cross dogs aged 2 +/- 0 years (mean +/- SD) weighing 30 +/- 5 kg and four Beagles aged 2 +/- 0 years and weighing 8.5 +/- 0.5 kg. Axillary brachial plexus, femoral, and sciatic combined ultrasound/electrolocation-guided nerve blocks were performed sequentially and bilaterally using a lidocaine solution mixed with methylene blue. Sciatic nerve blocks were not performed in the hounds. After the blocks, the dogs were euthanatized and each relevant site dissected. Axillary brachial plexus block Landmark blood vessels and the roots of the brachial plexus were identified by ultrasound in all eight dogs. Anatomical examination confirmed the relationship between the four ventral nerve roots (C6, C7, C8, and T1) and the axillary vessels. Three roots (C7, C8, and T1) were adequately stained bilaterally in all dogs. Femoral nerve block Landmark blood vessels (femoral artery and femoral vein), the femoral and saphenous nerves and the medial portion of the rectus femoris muscle were identified by ultrasound in all dogs. Anatomical examination confirmed the relationship between the femoral vessels, femoral nerve, and the rectus femoris muscle. The femoral nerves were adequately stained bilaterally in all dogs. Sciatic nerve block. Ultrasound landmarks (semimembranosus muscle, the fascia of the biceps femoris muscle and the sciatic nerve) could be identified in all of the dogs. In the four Beagles, anatomical examination confirmed the relationship between the biceps femoris muscle, the semimembranosus muscle, and the sciatic nerve. In the Beagles, all but one of the sciatic nerves were stained adequately. Ultrasound-guided needle insertion is an accurate method for depositing local anesthetic for axillary brachial plexus, femoral, and sciatic nerve blocks.

  4. Validation of a new classification system for interprosthetic femoral fractures.

    Science.gov (United States)

    Pires, Robinson Esteves Santos; Silveira, Marcelo Peixoto Sena; Resende, Alessandra Regina da Silva; Junior, Egidio Oliveira Santana; Campos, Tulio Vinicius Oliveira; Santos, Leandro Emilio Nascimento; Balbachevsky, Daniel; Andrade, Marco Antônio Percope de

    2017-07-01

    Interprosthetic femoral fracture (IFF) incidence is gradually increasing as the population is progressively ageing. However, treatment remains challenging due to several contributing factors, such as poor bone quality, patient comorbidities, small interprosthetic fragment, and prostheses instability. An effective and specific classification system is essential to optimize treatment management, therefore diminishing complication rates. This study aims to validate a previously described classification system for interprosthetic femoral fractures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Recommended reference materials for realization of physicochemical properties pressure-volume-temperature relationships

    CERN Document Server

    Herington, E F G

    1977-01-01

    Recommended Reference Materials for Realization of Physicochemical Properties presents recommendations of reference materials for use in measurements involving physicochemical properties, namely, vapor pressure; liquid-vapor critical temperature and critical pressure; orthobaric volumes of liquid and vapor; pressure-volume-temperature properties of the unsaturated vapor or gas; and pressure-volume-temperature properties of the compressed liquid. This monograph focuses on reference materials for vapor pressures at temperatures up to 770 K, as well as critical temperatures and critical pressures

  6. The research of establishing reactor materials thermophysical properties data base

    International Nuclear Information System (INIS)

    Luo Danhui; Zhong Jianguo; Zhang Lili; Zhao Yongming

    1992-01-01

    In the process of nuclear reactor design and safety analysis, the reactor materials thermophysical properties parameters are very important as the main input data of reactor design and calculation. The goal of this work is to establish a practical, reliable data base of reactor materials thermophysical properties parameters with obvious function in reactor design, operation and safety analysis. At present phase, the focal point of this data base is to collect the materials thermophysical properties data based on the need of safety analysis in light water reactor and heavy water reactor. The materials to be chosen are as follows: Uranium, U-Al alloy, UO 2 , UO 2 -PuO 2 mixture, Zr-2, Zr-4, Zr-1% Ni alloy, Inconel-625, ZrO 2 (oxidic layer), boron carbide, cadmium in stainless steel, silver-indium-cadmium alloy, light water and heavy water, etc. The following thermophysical properties parameters are mainly included in the data base: thermal conductivity, thermal diffusivity, specific heat capacity, heat of melting, coefficient of thermal expansion, emittance, density, heat of vaporization, kinematic viscosity etc. The first phase of this work has been finished, which includes the method of establishing reactor materials thermophysical properties data base, the requirement of data collection, the requirement of establishing data base and the method of the data evaluation. This data base has been established and used on PC computer

  7. Automatic quantification of tibio-femoral contact area and congruity

    DEFF Research Database (Denmark)

    Tummala, Sudhakar; Nielsen, Mads; Lillholm, Martin

    2012-01-01

    We present methods to quantify the medial tibio- femoral (MTF) joint contact area (CA) and congruity index (CI) from low-field magnetic resonance imaging (MRI). Firstly, based on the segmented MTF cartilage compartments, we computed the contact area using the Euclidian distance transformation....... The CA was defined as the area of the tibial superior surface and the femoral inferior surface that are less than a voxel width apart. Furthermore, the CI is computed point-by-point by assessing the first- and second-order general surface features over the contact area. Mathematically, it is the inverse...

  8. Avascular necrosis associated with nailing of femoral neck fracture

    International Nuclear Information System (INIS)

    Stroemqvist, B.; Hansson, L.I.

    1983-01-01

    Two patients with femoral neck fractures, one displaced and one undisplaced, are presented. Preoperative intravital staining with tetracycline and Tc-MDP scintimetry both showed intact femoral head circulation while Tc-MDP-scintimetry 1 week after operation showed pronounced circulatory deficiency. SR 85 -scintimetry performed at the same time was inconclusive. Segmental collapse was observed radiographically, 8 and 12 months postoperatively. The major vascular injury resulting in avascularity most probably occured during the procedure of osteosynthesis, and Tc-MDP-scintimetry was found suitable for early postoperative recognition of avascular necrosis in both fractures. (author)

  9. Avascular necrosis associated with nailing of femoral neck fracture

    Energy Technology Data Exchange (ETDEWEB)

    Stroemqvist, B; Hansson, L I [Department of Orthopaedic Surgery, University Hospital in Lund, Sweden

    1983-01-01

    Two patients with femoral neck fractures, one displaced and one undisplaced, are presented. Preoperative intravital staining with tetracycline and Tc-MDP scintimetry both showed intact femoral head circulation while Tc-MDP-scintimetry 1 week after operation showed pronounced circulatory deficiency. Sr/sup 85/-scintimetry performed at the same time was inconclusive. Segmental collapse was observed radiographically, 8 and 12 months postoperatively. The major vascular injury resulting in avascularity most probably occured during the procedure of osteosynthesis, and Tc-MDP-scintimetry was found suitable for early postoperative recognition of avascular necrosis in both fractures.

  10. Relationship of femoral artery ultrasound measures of atherosclerosis with chronic kidney disease.

    Science.gov (United States)

    Hsu, Simon; Rifkin, Dena E; Criqui, Michael H; Suder, Natalie C; Garimella, Pranav; Ginsberg, Charles; Marasco, Antoinette M; McQuaide, Belinda J; Barinas-Mitchell, Emma J; Allison, Matthew A; Wassel, Christina L; Ix, Joachim H

    2017-12-22

    Chronic kidney disease (CKD) is strongly associated with peripheral artery disease (PAD). Detection of subclinical PAD may allow early interventions for or prevention of PAD in persons with CKD. Whether the presence of atherosclerotic plaque and femoral intima-media thickness (IMT) are associated with kidney function is unknown. We performed a cross-sectional observational study of 1029 community-living adults. We measured superficial and common femoral artery IMT and atherosclerotic plaque presence by ultrasound. Estimated glomerular filtration rate (eGFR; continuous) and eGFR <60 mL/min/1.73 m 2 (binary) were evaluated as outcomes. Mean age was 70 ± 10 years, mean eGFR was 78 ± 17 mL/min/1.73 m 2 , and 156 (15%) individuals had eGFR <60 mL/min/1.73 m 2 ; 260 (25%) had femoral artery plaque. In models adjusted for demographics and cardiovascular risk factors, individuals with femoral artery plaque had mean eGFR approximately 3.0 (95% confidence interval, -5.3 to -0.8) mL/min/1.73 m 2 lower than those without plaque (P < .01). The presence of plaque was also associated with a 1.7-fold higher odds of eGFR <60 mL/min/1.73 m 2 (95% confidence interval, 1.1-2.8; P < .02). Associations were similar in persons with normal ankle-brachial index. The directions of associations were similar for femoral IMT measures with eGFR and CKD but were rendered no longer statistically significant with adjustment for demographic variables and cardiovascular disease risk factors. Femoral artery plaque is significantly associated with CKD prevalence in community-living individuals, even among those with normal ankle-brachial index. Femoral artery ultrasound may allow evaluation of relationships and risk factors linking PAD and kidney disease earlier in its course. Copyright © 2017 Society for Vascular Surgery. All rights reserved.

  11. Evaluation of effective material properties of spiral wound gasket through homogenization

    International Nuclear Information System (INIS)

    Mathan, G.; Siva Prasad, N.

    2010-01-01

    In this paper, a homogenization methodology is proposed to determine the material properties of spiral wound gaskets (SWGs) using finite element analysis through representative volume elements (RVE) of the gaskets. The constituents of this RVE are described by elasto-plastic material properties. The RVE are subjected to six load cases and the volume averaged responses are analyzed simultaneously to predict the anisotropic properties. The mechanical behaviour is simplified to an orthotropic material model with Hill's plasticity model and the properties are verified with micro-mechanical simulation and experimental results available in the literature. Reasonable agreement is obtained between the results. Formulae for elastic properties are also derived by a simplified analytical method based on lamination theory and compared with those obtained from homogenization.

  12. Evaluation of effective material properties of spiral wound gasket through homogenization

    Energy Technology Data Exchange (ETDEWEB)

    Mathan, G. [Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai 600036 (India); Siva Prasad, N., E-mail: siva@iitm.ac.i [Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai 600036 (India)

    2010-12-15

    In this paper, a homogenization methodology is proposed to determine the material properties of spiral wound gaskets (SWGs) using finite element analysis through representative volume elements (RVE) of the gaskets. The constituents of this RVE are described by elasto-plastic material properties. The RVE are subjected to six load cases and the volume averaged responses are analyzed simultaneously to predict the anisotropic properties. The mechanical behaviour is simplified to an orthotropic material model with Hill's plasticity model and the properties are verified with micro-mechanical simulation and experimental results available in the literature. Reasonable agreement is obtained between the results. Formulae for elastic properties are also derived by a simplified analytical method based on lamination theory and compared with those obtained from homogenization.

  13. Bipolar hip arthroplasty for avascular necrosis of femoral head in young adults

    Science.gov (United States)

    Dudani, Baldev; Shyam, Ashok K; Arora, Pankush; Veigus, Arjun

    2015-01-01

    Background: Bipolar hip arthroplasty (BHA) is one of the options for treatment of avascular necrosis (AVN) of the femoral head. Acetabular erosion and groin pain are the most allowing for gross motion between the common complications. We propose that these complications are secondary to improper acetabular preparation allowing for motion between the BHA head and the acetabulum. Materials and Methods: The current study retrospectively evaluated patients’records from case files and also called them for clinical and radiological followup. 96 hips with AVN of the femoral head treated with BHA were included in the study. All patients were males with a mean age of 42 years (range 30-59 years). In all cases, the acetabulum was gently reamed till it became uniformly concentric to achieve tight fitting trial cup. Clinical followup using Harris hip score (HHS) and radiological study for cup migration were done at followup. Results: The mean followup was 7.52 years (range 4-16 years). The HHS significantly improved from a preoperative value of 39.3 (range, 54-30) to a postoperative value of 89.12 (range 74-96). According to HHS grades, the final outcome was excellent in 52 hips, good in 28 and fair in 16 hips. Hip and groin pain was reported in four hips (5%), but did not limit activity. Subsidence (less than 5 mm) of the femoral component was seen in 8 cases. Subgroup analysis showed patients with Ficat Stage 3 having better range of motion, but similar HHS as compared to Ficat Stage 4 patients. Conclusion: Bipolar hip arthroplasty (BHA) using tight fitting cup and acetabular reaming in AVN hip has a low incidence of groin pain, acetabular erosion and revision in midterm followup. Good outcome and mid term survival can be achieved irrespective of the Ficat Stage. PMID:26015634

  14. Femoral head avascular necrosis: a frequently missed incidental finding on multidetector CT

    International Nuclear Information System (INIS)

    Barille, M.F.; Wu, Jim S.; McMahon, Colm J.

    2014-01-01

    Aim: To determine the incidence of missed femoral head avascular necrosis (AVN) on pelvic computed tomography (CT) performed for clinical indications other than assessment for AVN. Materials and methods: The study was a Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study. The picture archiving and communication system (PACS) database was queried for patients with diagnosis of femoral head AVN on magnetic resonance imaging (MRI), who also underwent pelvic multidetector CT after or <30 days before the MRI examination. The MRI and CT images of 144 hips of 72 patients (39 patients with reported AVN on MRI and 33 age-matched controls; mean age = 60 years, 28 male, 44 female), were reviewed in consensus by two readers in a randomized, blinded manner. Using MRI-proven CT-visible AVN as a reference standard, the incidence of missed AVN on initial CT interpretation was determined. Results: Readers confirmed AVN in 33 patients on the MRI images. Nine hips with AVN underwent joint replacement of the affected joint(s) prior to subsequent CT and were excluded. Forty-three MRI-proven AVN cases in 28 patients (15 bilateral, 13 unilateral) were available for analysis. The study readers diagnosed 35/43 (81%) MRI-proven AVN cases in 22/28 (79%) patients. Four of the 35 (11%) cases of MRI-proven, CT-visible AVN were prospectively reported in 3/22 (14%) patients at initial clinical interpretation, with a miss rate of 89% per hip and 86% per patient. Conclusion: Multidetector CT has high accuracy for detection of AVN; however, this is frequently missed as an incidental finding (89% missed in the present study). Assessment for signs of femoral AVN should be part of routine search pattern in interpretation of pelvic CT

  15. Molecular modeling of polycarbonate materials: Glass transition and mechanical properties

    Science.gov (United States)

    Palczynski, Karol; Wilke, Andreas; Paeschke, Manfred; Dzubiella, Joachim

    2017-09-01

    Linking the experimentally accessible macroscopic properties of thermoplastic polymers to their microscopic static and dynamic properties is a key requirement for targeted material design. Classical molecular dynamics simulations enable us to study the structural and dynamic behavior of molecules on microscopic scales, and statistical physics provides a framework for relating these properties to the macroscopic properties. We take a first step toward creating an automated workflow for the theoretical prediction of thermoplastic material properties by developing an expeditious method for parameterizing a simple yet surprisingly powerful coarse-grained bisphenol-A polycarbonate model which goes beyond previous coarse-grained models and successfully reproduces the thermal expansion behavior, the glass transition temperature as a function of the molecular weight, and several elastic properties.

  16. Outcome of pinning in patients with slipped capital femoral epiphysis: risk factors associated with avascular necrosis, chondrolysis, and femoral impingement.

    Science.gov (United States)

    Ulici, Alexandru; Carp, Madalina; Tevanov, Iulia; Nahoi, Catalin Alexandru; Sterian, Alin Gabriel; Cosma, Dan

    2018-06-01

    Objective This study aimed to assess the principal risk factors that could lead to the most common long-term complications of slipped capital femoral epiphysis, such as avascular necrosis, chondrolysis, and hip impingement. Methods We conducted a single-centre, retrospective study and evaluated patients (70 patients, 81 hips) who were treated for slipped capital femoral epiphysis from 2010 to 2015 and who underwent pinning. We measured the severity of displacement radiologically using the Southwick angle. Postoperative radiographs were evaluated for the most frequent long-term complications of avascular necrosis (AVN), chondrolysis, and femoral acetabular impingement (FAI). Results We found seven cases of AVN, 14 cases of chondrolysis, and 31 hips had an α angle of 60°. Sex, ambulation, and symptoms did not affect development of these complications. Patients with a normal weight were almost two times more likely to develop FAI. Patients with moderate and severe slips had a similar percentage of AVN. In severe slips, 85.7% of patients had an α angle higher than 60°. Conclusions This study shows that severe slips have a higher risk of developing AVN and hip impingement. Every patient who suffers from SCFE (even the mildest forms) should be regularly checked for FAI.

  17. [Clinical evaluation of the ceramic femoral component used for reconstruction of total knee replacement].

    Science.gov (United States)

    Vavrík, P; Landor, I; Denk, F

    2008-12-01

    replacements as compared to the hip are not convincing. One of the causes may be the substantially different and more complex biomechanics of the knee. Tribology improvement of the femoral ceramic component cannot compensate the deficiencies in the joint balancing in flexion and extension. The economically and technologically demanding production of these implants may be justified in patients with allergies caused by chrome-cobalt components. The results of mid-term follow-up of the use of zirconia ceramic femoral components proved no impact on the improvement of the period of survival of the knee implant. No adverse response to the material or mechanical failure of the ceramic components was encountered. Key words: total knee replacement, zirconia ceramic femoral component, TKR mid-term results, ceramic knee survival curve.

  18. Postmortem Femoral Blood Concentrations of Risperidone

    DEFF Research Database (Denmark)

    Linnet, Kristian; Johansen, Sys Stybe

    2014-01-01

    Postmortem femoral blood concentrations of the antipsychotic drug risperidone and the active metabolite 9-hydroxyrisperidone were determined by an achiral LC-MS/MS method in 38 cases. The cause of death was classified as unrelated to risperidone in 30 cases, in which the sum of the concentration ...

  19. Sociomedical sequels and quality of life in patients of old age group with proximal femoral fractures

    Directory of Open Access Journals (Sweden)

    T. A. Raskina

    2014-01-01

    Full Text Available The sociomedical significance of osteoporosis is determined by its sequels (vertebral and peripheral skeletal fractures that are responsible for high mortality and disability rates among persons in the old age group and accordingly for high material costs in the health care system.Objective: to study sociomedical sequels and quality of life in patients with proximal femoral fractures in the old age group.Subjects and methods. 956 patients with osteoporotic fractures were followed up. Major social sequels were traced in the patients 6, 12, and 24 months after femur fractures in relation to treatment options.Results. There were 10 (8.0% and 78 (66.7% bedridden patients in the surgical and medical treatment groups, respectively. Twenty four months after fracture, recovery of function was noted in 72 (57.6% and 32 (27.35% patients receiving surgical and medical treatment, respectively.Conclusion. The findings suggest that immediate and late sequels in patients with proximal femoral fractures depend on a treatment option.

  20. Spontaneous stress fractures of the femoral neck

    International Nuclear Information System (INIS)

    Dorne, H.L.; Lander, P.H.

    1985-01-01

    The diagnosis of spontaneous stress fractures of the femoral neck, a form of insufficiency stress fracture, can be missed easily. Patients present with unremitting hip pain without a history of significant trauma or unusual increase in daily activity. The initial radiographic features include osteoporosis, minor alterations of trabecular alignment, minimal extracortical or endosteal reaction, and lucent fracture lines. Initial scintigraphic examinations performed in three of four patients showed focal increased radionuclide uptake in two and no focal abnormality in one. Emphasis is placed on the paucity of early findings. Evaluation of patients with persistent hip pain requires a high degree of clinical suspicion and close follow-up; the sequelae of undetected spontaneous fractures are subcapital fracture with displacement, angular deformity, and a vascular necrosis of the femoral head

  1. Radiographic landmarks for locating the femoral origin of the superficial medial collateral ligament.

    Science.gov (United States)

    Hartshorn, Timothy; Otarodifard, Karimdad; White, Eric A; Hatch, George F Rick

    2013-11-01

    Little has been written about the use of radiographic landmarks for locating the origin of the superficial medial collateral ligament (sMCL). A standardized radiographic landmark for the sMCL origin using intraoperative fluoroscopic imaging may be of value in aiding the surgeon in accurate femoral tunnel placement in the setting of extensive soft tissue disruption and bony attrition. To determine a reproducible radiographic landmark that will assist in correct femoral tunnel placement in sMCL repair and reconstruction. Descriptive laboratory study. Ten fresh-frozen unmatched human cadaveric knees were dissected, and the origin of the sMCL was exposed. A 2-mm metallic marker was then placed at the center of the femoral origin of the sMCL. True lateral fluoroscopically assisted digital radiographs were obtained of the knee with the posterior and distal femoral condyles overlapping in a standardized fashion. With the use of computer software, reference lines were drawn on the images, creating 4 quadrants. Two independent examiners performed quantitative measurements of the sMCL origin in relation to this axis and to the Blumensaat line. Mean measurements showed the sMCL origin to be closely related to the intersection point of the Blumensaat line and a line drawn distally from the posterior femoral cortex on a true lateral radiograph. The sMCL origin was found at a mean point 1.6 ± 4.3 mm posterior and 4.9 ± 2.1 mm proximal to the intersection of a line paralleling the posterior femoral cortex and a line drawn perpendicular to the posterior femoral cortical line, where it intersects the Blumensaat line. In 5 of 10 specimens, the center of the sMCL origin fell precisely on the Blumensaat line. The remaining specimens had sMCL origins anterior to the Blumensaat line. The femoral origin of the sMCL was found in the proximal and posterior quadrants in 8 of 10 specimens. With a relatively small amount of deviation, the sMCL origin can be consistently identified on a true

  2. Properties of Residue from Olive Oil Extraction as a Raw Material for Sustainable Construction Materials. Part I: Physical Properties

    Directory of Open Access Journals (Sweden)

    Almudena Díaz-García

    2017-01-01

    Full Text Available Action on climate, the environment, and the efficient use of raw materials and resources are important challenges facing our society. Against this backdrop, the construction industry must adapt to new trends and environmentally sustainable construction systems, thus requiring lines of research aimed at keeping energy consumption in new buildings as low as possible. One of the main goals of this research is to efficiently contribute to reducing the amount of residue from olive oil extraction using a two-phase method. This can be achieved by producing alternative structural materials to be used in the construction industry by means of a circular economy. The technical feasibility of adding said residue to ceramic paste was proven by analyzing the changes produced in the physical properties of the paste, which were then compared to the properties of the reference materials manufactured with clay without residue. Results obtained show that the heating value of wet pomace can contribute to the thermal needs of the sintering process, contributing 30% of energy in pieces containing 3% of said material. Likewise, adding larger amounts of wet pomace to the clay body causes a significant decrease in bulk density values.

  3. Properties of Residue from Olive Oil Extraction as a Raw Material for Sustainable Construction Materials. Part I: Physical Properties.

    Science.gov (United States)

    Díaz-García, Almudena; Martínez-García, Carmen; Cotes-Palomino, Teresa

    2017-01-25

    Action on climate, the environment, and the efficient use of raw materials and resources are important challenges facing our society. Against this backdrop, the construction industry must adapt to new trends and environmentally sustainable construction systems, thus requiring lines of research aimed at keeping energy consumption in new buildings as low as possible. One of the main goals of this research is to efficiently contribute to reducing the amount of residue from olive oil extraction using a two-phase method. This can be achieved by producing alternative structural materials to be used in the construction industry by means of a circular economy. The technical feasibility of adding said residue to ceramic paste was proven by analyzing the changes produced in the physical properties of the paste, which were then compared to the properties of the reference materials manufactured with clay without residue. Results obtained show that the heating value of wet pomace can contribute to the thermal needs of the sintering process, contributing 30% of energy in pieces containing 3% of said material. Likewise, adding larger amounts of wet pomace to the clay body causes a significant decrease in bulk density values.

  4. Static Magnetic Properties of AL800 Garnet Material

    Energy Technology Data Exchange (ETDEWEB)

    Kuharik, J. [Fermilab; Madrak, R. [Fermilab; Makarov, A. [Fermilab; Pellico, W. [Fermilab; Sun, S. [Fermilab; Tan, C. Y. [Fermilab; Terechkine, I. [Fermilab

    2017-05-17

    A second harmonic tunable RF cavity is being devel-oped for the Fermilab Booster. This device, which prom-ises reduction of the particle beam loss at the injection, transition, and extraction stages, employs perpendicularly biased garnet material for frequency tuning. The required range of the tuning is significantly wider than in previously built and tested tunable RF devices. As a result, the mag-netic field in the garnet comes fairly close to the gyromag-netic resonance line at the lower end of the frequency range. The chosen design concept of a tuner for the cavity cannot ensure uniform magnetic field in the garnet mate-rial; thus, it is important to know the static magnetic prop-erties of the material to avoid significant increase in the lo-cal RF loss power density. This report summarizes studies performed at Fermilab to understand variations in the mag-netic properties of the AL800 garnet material used to build the tuner of the cavity.

  5. Early detection of femoral head avascular necrosis by bone SPECT compared to MRI in renal allograft recipients

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young; Yang, Seoung Oh; Lee, Hee Kyung; Han, Duck Jong; Shin, Myung Jin [Asan Mecical Center, Seoul (Korea, Republic of)

    1997-07-01

    The prevalence of avascular necrosis (AVN) of femoral head in patients who receive immunosuppresive agents after renal transplantation is reported to be 4-29%. Among patients who develop AVN after renal transplantation, 80% become symptomatic within 2 years after transplantation. As the number of renal transplantation has been increased recently, early detection of femoral head AVN is very important because early surgical core decompression of femoral head can prevent collapse of the head. MRI is known to be very sensitive to diagnose femoral head AVN. However in three cases we report here, bone SPECT showed early changes of femoral head AVN, whereas MRI showed no specific abnormality. Case 1. A 53-year-old female received an allograft kidney transplantation in 1994. Preoperative bone scan was normal. She complained of both hip pain on Mar. 18 1997. Bone SPECT showed cold defect in both femoral heads but MRI showed no abnormality. After 3 months, bone SPECT and MRI showed AVN of both femoral heads. She underwent bilateral total hip replacement arthroplasty. AVN of femoral heads was confirmed by microscopic examination. Case 2. A 38-year-old female received an allograft kidney transplantation in Feb. 27 1997. Preoperative bone scan was normal. She ran a fever and creatinine was elevated from 1.2 to 2.8 mg/dL. She took high dose methylprednisolone therapy for acute reanl rejection. After two days, she complained pain in both hip joints and knee joints. Bone SPECT showed cold defects in both femoral heads but MRI showed no abnormality. A follow-up bone SPECT and MRI 20 days later revealed AVN of both femoral heads. Case 3. A 50-year-old male received an allograft kidney transplantation on Jul. 12 1995. Preoperative bone scan was normal. He complained of right hip pain on Jul, 26 1995. His bone SPECT showed cold defects in both femoral heads while MRI showed only minimal hip joint effusion. He also complained of left hip pain on Oct. 2 1995. He was admitted on Mar 17

  6. Early detection of femoral head avascular necrosis by bone SPECT compared to MRI in renal allograft recipients

    International Nuclear Information System (INIS)

    Kang, Do Young; Yang, Seoung Oh; Lee, Hee Kyung; Han, Duck Jong; Shin, Myung Jin

    1997-01-01

    The prevalence of avascular necrosis (AVN) of femoral head in patients who receive immunosuppresive agents after renal transplantation is reported to be 4-29%. Among patients who develop AVN after renal transplantation, 80% become symptomatic within 2 years after transplantation. As the number of renal transplantation has been increased recently, early detection of femoral head AVN is very important because early surgical core decompression of femoral head can prevent collapse of the head. MRI is known to be very sensitive to diagnose femoral head AVN. However in three cases we report here, bone SPECT showed early changes of femoral head AVN, whereas MRI showed no specific abnormality. Case 1. A 53-year-old female received an allograft kidney transplantation in 1994. Preoperative bone scan was normal. She complained of both hip pain on Mar. 18 1997. Bone SPECT showed cold defect in both femoral heads but MRI showed no abnormality. After 3 months, bone SPECT and MRI showed AVN of both femoral heads. She underwent bilateral total hip replacement arthroplasty. AVN of femoral heads was confirmed by microscopic examination. Case 2. A 38-year-old female received an allograft kidney transplantation in Feb. 27 1997. Preoperative bone scan was normal. She ran a fever and creatinine was elevated from 1.2 to 2.8 mg/dL. She took high dose methylprednisolone therapy for acute reanl rejection. After two days, she complained pain in both hip joints and knee joints. Bone SPECT showed cold defects in both femoral heads but MRI showed no abnormality. A follow-up bone SPECT and MRI 20 days later revealed AVN of both femoral heads. Case 3. A 50-year-old male received an allograft kidney transplantation on Jul. 12 1995. Preoperative bone scan was normal. He complained of right hip pain on Jul, 26 1995. His bone SPECT showed cold defects in both femoral heads while MRI showed only minimal hip joint effusion. He also complained of left hip pain on Oct. 2 1995. He was admitted on Mar 17

  7. Computational methods for 2D materials: discovery, property characterization, and application design.

    Science.gov (United States)

    Paul, J T; Singh, A K; Dong, Z; Zhuang, H; Revard, B C; Rijal, B; Ashton, M; Linscheid, A; Blonsky, M; Gluhovic, D; Guo, J; Hennig, R G

    2017-11-29

    The discovery of two-dimensional (2D) materials comes at a time when computational methods are mature and can predict novel 2D materials, characterize their properties, and guide the design of 2D materials for applications. This article reviews the recent progress in computational approaches for 2D materials research. We discuss the computational techniques and provide an overview of the ongoing research in the field. We begin with an overview of known 2D materials, common computational methods, and available cyber infrastructures. We then move onto the discovery of novel 2D materials, discussing the stability criteria for 2D materials, computational methods for structure prediction, and interactions of monolayers with electrochemical and gaseous environments. Next, we describe the computational characterization of the 2D materials' electronic, optical, magnetic, and superconducting properties and the response of the properties under applied mechanical strain and electrical fields. From there, we move on to discuss the structure and properties of defects in 2D materials, and describe methods for 2D materials device simulations. We conclude by providing an outlook on the needs and challenges for future developments in the field of computational research for 2D materials.

  8. Femoral head fracture without hip dislocation

    Directory of Open Access Journals (Sweden)

    Aggarwal Aditya K

    2013-10-01

    Full Text Available 【Abstract】Femoral head fractures without dislocation or subluxation are extremely rare injuries. We report a neglected case of isolated comminuted fracture of femoral head without hip dislocation or subluxation of one year duration in a 36-year-old patient who sustained a high en- ergy trauma due to road traffic accident. He presented with painful right hip and inability to bear full weight on right lower limb with Harris hip score of 39. He received cementless total hip replacement. At latest follow-up of 2.3 years, functional outcome was excellent with Harris hip score of 95. Such isolated injuries have been described only once in the literature and have not been classified till now. The purpose of this report is to highlight the extreme rarity, possible mechanism involved and a novel classification system to classify such injuries. Key words: Femur head; Hip dislocation; Classification; Arthroplasty, replacement, hip

  9. Electrical properties of materials

    CERN Document Server

    Solymar, L; Syms, R R A

    2014-01-01

    An informal and highly accessible writing style, a simple treatment of mathematics, and clear guide to applications have made this book a classic text in electrical and electronic engineering. Students will find it both readable and comprehensive. The fundamental ideas relevant to the understanding of the electrical properties of materials are emphasized; in addition, topics are selected in order to explain the operation of devices having applications (or possible future applications) in engineering. The mathematics, kept deliberately to a minimum, is well within the grasp of a second-year student. This is achieved by choosing the simplest model that can display the essential properties of a phenomenom, and then examining the difference between the ideal and the actual behaviour. The whole text is designed as an undergraduate course. However most individual sections are self contained and can be used as background reading in graduate courses, and for interested persons who want to explore advances in microele...

  10. Electromechanical actuation of buckypaper actuator: Material properties and performance relationships

    International Nuclear Information System (INIS)

    Cottinet, P.-J.; Souders, C.; Tsai, S.-Y.; Liang, R.; Wang, B.; Zhang, C.

    2012-01-01

    Carbon nanotubes can be assembled into macroscopic thin film materials called buckypapers. To incorporate buckypaper actuators into engineering systems, it is of high importance to understand their material property-actuation performance relationships in order to model and predict the behavior of these actuators. The electromechanical actuation of macroscopic buckypaper structures and their actuators, including single and multi-walled carbon nanotube buckypapers and aligned single-walled nanotube buckypapers, were analyzed and compared. From the experimental evidence, this Letter discusses the effects of the fundamental material properties, including Young modulus and electrical double layer properties, on actuation performance of the resultant actuators. -- Highlights: ► In this study we identified the figure of merit of the electromechanical conversion. ► Different type of buckypaper was realized and characterized for actuation properties. ► The results demonstrated the potential of Buckypapers/Nafion for actuation

  11. Dislocation of total hip replacement in patients with fractures of the femoral neck.

    Science.gov (United States)

    Enocson, Anders; Hedbeck, Carl-Johan; Tidermark, Jan; Pettersson, Hans; Ponzer, Sari; Lapidus, Lasse J

    2009-04-01

    Total hip replacement is increasingly used in active, relatively healthy elderly patients with fractures of the femoral neck. Dislocation of the prosthesis is a severe complication, and there is still controversy regarding the optimal surgical approach and its influence on stability. We analyzed factors influencing the stability of the total hip replacement, paying special attention to the surgical approach. We included 713 consecutive hips in a series of 698 patients (573 females) who had undergone a primary total hip replacement (n = 311) for a non-pathological, displaced femoral neck fracture (Garden III or IV) or a secondary total hip replacement (n = 402) due to a fracture-healing complication after a femoral neck fracture. We used Cox regression to evaluate factors associated with prosthetic dislocation after the operation. Age, sex, indication for surgery, the surgeon's experience, femoral head size, and surgical approach were tested as independent factors in the model. The overall dislocation rate was 6%. The anterolateral surgical approach was associated with a lower risk of dislocation than the posterolateral approach with or without posterior repair (2%, 12%, and 14%, respectively (p replacement in patients with femoral neck fractures.

  12. Biphasic threat to femoral head perfusion in abduction: arterial hypoperfusion and venous congestion

    Energy Technology Data Exchange (ETDEWEB)

    Yousefzadeh, David K. [Comer Children' s Hospital, Department of Radiology, Chicago, IL (United States); University of Chicago, Department of Radiology, Chicago, IL (United States); Jaramillo, Diego [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Johnson, Neil [Cincinnati Children' s Hospital, Department of Radiology, Cincinnati, OH (United States); Doerger, Kirk [Radiology Associates of Northern Kentucky, Crestview Hills, KY (United States); Sullivan, Christopher [University of Chicago, Department of Surgery, Chicago, IL (United States)

    2010-09-15

    Hip abduction can cause avascular necrosis (AVN) of the femoral head in infants. To compare the US perfusion pattern of femoral head cartilage in neutral position with that in different degrees and duration of abduction, testing the venous congestion theory of post-abduction ischemia. In 20 neonates, the Doppler flow characteristics of the posterosuperior (PS) branch of the femoral head cartilage feeding vessels were evaluated in neutral and at 30 , 45 , and 60 abduction. In three neonates the leg was held in 45-degree abduction and flow was assessed at 5, 10, and 15 min. Male/female ratio was 11/9 with a mean age of 1.86 {+-} 0.7 weeks. The peak systolic velocities (PSV) declined in all three degrees of abduction. After 15 min of 45-degree abduction, the mean PSV declined and showed an absent or reversed diastolic component and undetectable venous return. No perfusion was detected at 60-degree abduction. Abduction-induced femoral head ischemia is biphasic and degree- and duration-dependent. In phase I there is arterial hypoperfusion and in phase II there is venous congestion. A new pathogeneses for femoral head ischemia is offered. (orig.)

  13. Measurement of Mechanical Properties of Cantilever Shaped Materials

    Directory of Open Access Journals (Sweden)

    Thomas Thundat

    2008-05-01

    Full Text Available Microcantilevers were first introduced as imaging probes in Atomic Force Microscopy (AFM due to their extremely high sensitivity in measuring surface forces. The versatility of these probes, however, allows the sensing and measurement of a host of mechanical properties of various materials. Sensor parameters such as resonance frequency, quality factor, amplitude of vibration and bending due to a differential stress can all be simultaneously determined for a cantilever. When measuring the mechanical properties of materials, identifying and discerning the most influential parameters responsible for the observed changes in the cantilever response are important. We will, therefore, discuss the effects of various force fields such as those induced by mass loading, residual stress, internal friction of the material, and other changes in the mechanical properties of the microcantilevers. Methods to measure variations in temperature, pressure, or molecular adsorption of water molecules are also discussed. Often these effects occur simultaneously, increasing the number of parameters that need to be concurrently measured to ensure the reliability of the sensors. We therefore systematically investigate the geometric and environmental effects on cantilever measurements including the chemical nature of the underlying interactions. To address the geometric effects we have considered cantilevers with a rectangular or circular cross section. The chemical nature is addressed by using cantilevers fabricated with metals and/or dielectrics. Selective chemical etching, swelling or changes in Young’s modulus of the surface were investigated by means of polymeric and inorganic coatings. Finally to address the effect of the environment in which the cantilever operates, the Knudsen number was determined to characterize the molecule-cantilever collisions. Also bimaterial cantilevers with high thermal sensitivity were used to discern the effect of temperature

  14. Slip of the capital femoral epiphysis: Revival of a method of assessment

    International Nuclear Information System (INIS)

    Billing, L.; Ekloef, O.

    1984-01-01

    A simple and exact method for evaluation of suspected or overt slip of the femoral capital epiphysis is revived. This procedure gives an estimate of all degrees of abnormality from the early stages to those with gross deformity. In our experience slip of the femoral capital epiphysis is always posterior and in approximately 80% of cases bilateral. Therefore, bot hips should be examined whenever this condition is suspected. The method provides for examination of each hip separately. Strict adherence to the procedure also provides a precise way of assessing the femoral anteversion angle, significant in many orthopedic disorders. For the latter purpose access to a particular nomogram is mandatory. (orig.)

  15. Reduction of femoral fractures in long-term care facilities: the Bavarian fracture prevention study.

    Directory of Open Access Journals (Sweden)

    Clemens Becker

    Full Text Available BACKGROUND: Hip fractures are a major public health burden. In industrialized countries about 20% of all femoral fractures occur in care dependent persons living in nursing care and assisted living facilities. Preventive strategies for these groups are needed as the access to medical services differs from independent home dwelling older persons at risk of osteoporotic fractures. It was the objective of the study to evaluate the effect of a fall and fracture prevention program on the incidence of femoral fracture in nursing homes in Bavaria, Germany. METHODS: In a translational intervention study a fall prevention program was introduced in 256 nursing homes with 13,653 residents. The control group consisted of 893 nursing homes with 31,668 residents. The intervention consisted of staff education on fall and fracture prevention strategies, progressive strength and balance training, and on institutional advice on environmental adaptations. Incident femoral fractures served as outcome measure. RESULTS: In the years before the intervention risk of a femoral fracture did not differ between the intervention group (IG and control group (CG. During the one-year intervention period femoral fracture rates were 33.6 (IG and 41.0/1000 person years (CG, respectively. The adjusted relative risk of a femoral fracture was 0.82 (95% CI 0.72-0.93 in residents exposed to the fall and fracture prevention program compared to residents from CG. CONCLUSIONS: The state-wide dissemination of a multi-factorial fall and fracture prevention program was able to reduce femoral fractures in residents of nursing homes.

  16. In vivo evaluation of femoral blood flow measured with magnetic resonance

    International Nuclear Information System (INIS)

    Henriksen, O.; Staahlberg, F.; Thomsen, C.; Moegelvang, J.; Persson, B.; Lund Univ.

    1989-01-01

    Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve, corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory arrest. The mean T2 of non-flowing blood was found to be 105±31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate that in vivo blood flow measurements made with MRI based on wash-out effects, commonly used in multiple spin echo imaging, do not give reliable absolute values for blood flow in the femoral artery or vein. (orig.)

  17. A Case of Late Femoral Pseudoaneurysm Caused by Stent Disconnection

    International Nuclear Information System (INIS)

    Rivolta, Nicola; Fontana, Federico; Piffaretti, Gabriele; Tozzi, Matteo; Carrafiello, Gianpaolo

    2010-01-01

    We present the case of a late superficial femoral artery stent disconnection causing an asymptomatic pseudoaneurysm successfully treated with a stent-graft. A 67-year-old female was referred to our department for evaluation of claudication of the left lower limb and was diagnosed to have a total occlusion of the superficial femoral artery. Three nitinol stents were used to revascularize this artery. At 48 months, duplex-ultrasonography control revealed the presence of a 45-mm saccular femoral dilatation; X-rays and CT angiography showed fractures of the proximal stents and the presence of a pseudoaneurysm at the site of the distal stents disconnection. The pseudoaneurysm was excluded using two stent-grafts. We conclude that patients and surgeons should be aware of structural complications with all stents. Rigorous follow-up controls should be mandatory. Endovascular repair proved to be feasible and durable to manage a previous endovascular procedure.

  18. Femoral nerve block versus intravenous fentanyl in adult patients with hip fractures - a systematic review

    Directory of Open Access Journals (Sweden)

    Flávia Vieira Guimarães Hartmann

    Full Text Available Abstract Background: Hip fractures configure an important public health issue and are associated with high mortality taxes and lose of functionality. Hip fractures refer to a fracture occurring between the edge of the femoral head and 5 cm below the lesser trochanter. They are common in orthopedic emergencies. The number of proximal femoral fractures is likely to increase as the population ages. The average cost of care during the initial hospitalization for hip fracture can be estimated about US$ 7,000 per patient. Femoral fractures are painful and need immediate adequate analgesia. Treating pain femoral fractures is difficult because there are limited numbers of analgesics available, many of which have side effects that can limit their use. Opiates are the most used drugs, but they can bring some complications. In this context, femoral nerve blocks can be a safe alternative. It is a specific regional anesthetic technique used by doctors in emergency medicine to provide anesthesia and analgesia of the affected leg. Objective: To compare the analgesic efficacy of intravenous fentanyl versus femoral nerve block before positioning to perform spinal anesthesia in patients with femoral fractures assessed by Pain Scales. Methods: A systematic review of scientific literature was conducted. Studies described as randomized controlled trials comparing femoral nerve block and traditional fentanyl are included. Two reviewers (MR and FH independently assessed potentially eligible trials for inclusion. The methodology assessment was based on the tool developed by the Cochrane Collaboration for assessment of bias for randomized controlled trials. The Cochrane Library, Pubmed, Medline and Lilacs were searched for all articles published, without restriction of language or time. Results: Two studies were included in this review. Nerve blockade seemed to be more effective than intravenous fentanyl for preventing pain in patients suffering from a femoral fracture

  19. Radiographic features of teriparatide-induced healing of femoral fractures

    Directory of Open Access Journals (Sweden)

    Youngwoo Kim

    2015-12-01

    Full Text Available Teriparatide is a drug that is used to increase bone remodeling, formation, and density for the treatment of osteoporosis. We present three cases of patients with a femoral insufficiency fracture. The patients were administered teripatatide in an attempt to treat severe osteoporosis and to enhance fracture healing. We found several radiographic features around the femoral fractures during the healing period. 1 Callus formation was found at a very early stage in the treatment. Teriparatide substantially increased the unusually abundant callus formation around the fracture site at 2 weeks. Moreover, this callus formation continued for 8 weeks and led to healing of the fracture. 2 Abundant callus formation was found circumferentially around the cortex with a ‘cloud-like’ appearance. 3 Remodeling of the teriparatide-induced callus formation was found to be part of the normal fracture healing process. After 1 year, normal remodeling was observed on plain radiographs. These findings indicate that teriparatide can be used as an adjuvant therapy in the management of femoral insufficiency fractures.

  20. Three-stage treatment protocol for recalcitrant distal femoral nonunion.

    Science.gov (United States)

    Ma, Ching-Hou; Chiu, Yen-Chun; Tu, Yuan-Kun; Yen, Cheng-Yo; Wu, Chin-Hsien

    2017-04-01

    In this study, we proposed a three-stage treatment protocol for recalcitrant distal femoral nonunion and aimed to analyze the clinical results. We retrospective reviewed 12 consecutive patients with recalcitrant distal femoral nonunion undergoing our three-stage treatment protocol from January 2010 to December 2014 in our institute. The three-stage treatment protocol comprised debridement of the nonunion site, lengthening to eliminate leg length discrepancy, deformity correction, stabilization with a locked plate, filling of the defect with cement spacer for inducing membrane formation, and bone reconstruction using a cancellous bone autograft (Masquelet technique) or free vascularized fibular bone graft. The bone union time, wound complication, lower limbs alignment, amount of lengthening, knee range of motion, and functional outcomes were evaluated. Osseous union with angular deformity lengthening was 5.88 cm (range 3.5-12 cm). Excellent or good outcomes were obtained in 9 patients. Although the current study involved only a small number of patients and the intervention comprised three stages, we believe that such a protocol may be a valuable alternative for the treatment of recalcitrant distal femoral nonunion.

  1. Influence of man-made aluminosilicate raw materials on physical and mechanical properties of building materials.

    Science.gov (United States)

    Volodchenko, A. A.; Lesovik, V. S.; Stoletov, A. A.; Glagolev, E. S.; Volodchenko, A. N.; Magomedov, Z. G.

    2018-03-01

    It has been identified that man-made aluminosilicate raw materials represented by clay rock of varied genesis can be used as energy-efficient raw materials to obtain efficient highly-hollow non-autoclaved silicate materials. A technique of structure formation in the conditions of pressureless steam treatment has been offered. Cementing compounds of non- autoclaved silicate materials based on man-made aluminosilicate raw materials possess hydraulic properties that are conditioned by the process of further formation and recrystallization of calcium silicate hydrates, which optimizes the ratio between gellike and crystalline components and densifies the cementing compound structure, which leads to improvement of performance characteristics. Increasing the performance characteristics of the obtained products is possible by changing the molding conditions. For this reason, in order to create high-density material packaging and, as a result, to increase the strength properties of the products, it is reasonable to use higher pressure, under which raw brick is formed, which will facilitate the increase of quality of highly-hollow products.

  2. Fatigue design of a mechanically biocompatible lattice for a proof-of-concept femoral stem.

    Science.gov (United States)

    Arabnejad Khanoki, Sajad; Pasini, Damiano

    2013-06-01

    A methodology is proposed to design a spatially periodic microarchitectured material for a two-dimensional femoral implant under walking gait conditions. The material is composed of a graded lattice with controlled property distribution that minimizes concurrently bone resorption and interface failure. The periodic microstructure of the material is designed for fatigue fracture caused by cyclic loadings on the hip joint as a result of walking. The bulk material of the lattice is Ti6AL4V and its microstructure is assumed free of defects. The Soderberg diagram is used for the fatigue design under multiaxial loadings. Two cell topologies, square and Kagome, are chosen to obtain optimized property gradients for a two-dimensional implant. Asymptotic homogenization (AH) theory is used to address the multiscale mechanics of the implant as well as to capture the stress and strain distribution at both the macro and the microscale. The microstress distribution found with AH is also compared with that obtained from a detailed finite element analysis. For the maximum value of the von Mises stress, we observe a deviation of 18.6% in unit cells close to the implant boundary, where the AH assumption of spatial periodicity of the fluctuating fields ceases to hold. In the second part of the paper, the metrics of bone resorption and interface shear stress are used to benchmark the graded cellular implant with existing prostheses made of fully dense titanium implant. The results show that the amount of initial postoperative bone loss for square and Kagome lattice implants decreases, respectively, by 53.8% and 58%. In addition, the maximum shear interface failure at the distal end is significantly reduced by about 79%. A set of proof-of-concepts of planar implants have been fabricated via Electron Beam Melting (EBM) to demonstrate the manufacturability of Ti6AL4V into graded lattices with alternative cell size. Optical microscopy has been used to measure the morphological parameters

  3. SEX DETERMINATION FROM FEMORAL HEAD DIAMETERS IN ...

    African Journals Online (AJOL)

    hi-tech

    2000-03-01

    Mar 1, 2000 ... In medico-legal cases where sophisticated methods of sex determination is lacking, these ... scientific methods(3). Using the visual method ... between the sexes and the values of the right and left femoral head diameters.

  4. Effects of a physiological GH pulse on interstitial glycerol in abdominal and femoral adipose tissue

    DEFF Research Database (Denmark)

    Gravhølt, C H; Schmitz, Ole; Simonsen, L

    1999-01-01

    .0005). Administration of GH induced an increase in interstitial glycerol in both abdominal and femoral adipose tissue (ANOVA: abdominal, P = 0. 04; femoral, P = 0.03). There was no overall difference in the response to GH in the two regions during the study period as a whole (ANOVA: P = 0.5), but during peak...... stimulation of lipolysis abdominal adipose tissue was, in absolute but not in relative terms, stimulated more markedly than femoral adipose tissue (ANOVA: P = 0. 03 from 45 to 225 min). Peak interstitial glycerol values of 253 +/- 37 and 336 +/- 74 micromol/l were seen after 135 and 165 min in femoral...... and abdominal adipose tissue, respectively. ATBF was not statistically different in the two situations (ANOVA: P = 0.7). In conclusion, we have shown that a physiological pulse of GH increases interstitial glycerol concentrations in both femoral and abdominal adipose tissue, indicating activated lipolysis...

  5. Bilateral avascular necrosis of the femoral head following asynchronous postictal femoral neck fractures: a case report and review of the literature.

    Science.gov (United States)

    Venkatadass, K; Avinash, M; Rajasekaran, S

    2018-05-01

    Bilateral avascular necrosis (AVN) following postictal bilateral fracture neck of the femur is a rare occurrence. Here, we report a case of bilateral AVN of the femoral head following an asynchronous bilateral postictal fracture neck of the femur. A 16-year-old autistic boy presented with left hip pain following an episode of seizures and radiographs showed Delbet type II fracture neck of the left femur. This was treated by closed reduction and cancellous screw fixation and skeletal traction for 6 weeks. At 3 months, follow-up radiograph showed union of the fracture, but he had developed segmental AVN with collapse of the head. At 8 months, the patient presented with pain in the right hip following another episode of seizures and radiograph of the pelvis showed a fresh Delbet type II fracture neck of the right femur with established AVN of the left femoral head. He underwent closed reduction and cancellous screw fixation of the right hip and implant exit of the left hip. At the 6-month follow-up after this surgery, his radiograph of the pelvis showed AVN with collapse and extrusion of the femoral head on the right side as well. Literature review shows an increased risk of fracture neck of the femur among epileptics. The incidence of AVN is maximum in Delbet type I, followed by Delbet type II and type III in that order. Although there are no clear guidelines on the management of post-traumatic AVN of the femoral head, the majority have reported that most of them will eventually develop arthritis and will require total hip replacement at a later date. Upon extensive literature search, no case report of bilateral fracture neck of the femur with bilateral AVN was found and hence this case was reported.

  6. Properties of porous netted materials

    International Nuclear Information System (INIS)

    Daragan, V.D.; Drozdov, B.G.; Kotov, A.Yu.; Mel'nikov, G.N.; Pustogarov, A.V.

    1987-01-01

    Hydraulic and strength characteristics, efficient heat conduction and inner heat exchange coefficient are experimentally studied for porous netted materials on the base of the brass nets as dependent on porosity, cell size and method of net laying. Results of the studies are presented. It is shown that due to anisotropy of the material properties the hydraulic resistance in the direction parallel to the nets plane is 1.3-1.6 times higher than in the perpendicular one. Values of the effective heat conduction in the direction perpendicular to the nets plane at Π>0.45 agree with the data from literature, at Π<0.45 a deviation from the calculated values is marked in the direction of the heat conduction decrease

  7. State-of-the-art review of materials properties of nuclear waste forms

    International Nuclear Information System (INIS)

    Mendel, J.E.; Nelson, R.D.; Turcotte, R.P.; Gray, W.J.; Merz, M.D.; Roberts, F.P.; Weber, W.J.; Westsik, J.H. Jr.; Clark, D.E.

    1981-04-01

    The Materials Characterization Center (MCC) was established at the Pacific Northwest Laboratory to assemble a standardized nuclear waste materials data base for use in research, systems and facility design, safety analyses, and waste management decisions. This centralized data base will be provided through the means of a Nuclear Waste Materials Handbook. The first issue of the Handbook will be published in the fall of 1981 in looseleaf format so that it can be updated as additional information becomes available. To ensure utmost reliability, all materials data appearing in the Handbook will be obtained by standard procedures defined in the Handbook and approved by an independent Materials Review Board (MRB) comprised of materials experts from Department of Energy laboratories and from universities and industry. In the interim before publication of the Handbook there is need for a report summarizing the existing materials data on nuclear waste forms. This review summarizes materials property data for the nuclear waste forms that are being developed for immobilization of high-level radioactive waste. It is intended to be a good representation of the knowledge concerning the properties of HLW forms as of March 1981. The table of contents lists the following topics: introduction which covers waste-form categories, and important waste-form materials properties; physical properties; mechanical properties; chemical durability; vaporization; radiation effects; and thermal phase stability

  8. Total knee arthroplasty using patient-specific blocks after prior femoral fracture without hardware removal

    Directory of Open Access Journals (Sweden)

    Raju Vaishya

    2018-01-01

    Full Text Available Background: The options to perform total knee arthroplasty (TKA with retained hardware in femur are mainly – removal of hardware, use of extramedullary guide, or computer-assisted surgery. Patient-specific blocks (PSBs have been introduced with many potential advantages, but their use in retained hardware has not been adequately explored. The purpose of the present study was to outline and assess the usefulness of the PSBs in performing TKA in patients with retained femoral hardware. Materials and Materials and Methods: Nine patients with retained femoral hardware underwent TKA using PSBs. All the surgeries were performed by the same surgeon using same implants. Nine cases (7 males and 2 females out of total of 120 primary TKA had retained hardware. The average age of the patients was 60.55 years. The retained hardware were 6 patients with nails, 2 with plates and one patient had screws. Out of the nine cases, only one patient needed removal of a screw which was hindering placement of pin for the PSB. Results: All the patients had significant improvement in their Knee Society Score (KSS which improved from 47.0 to postoperative KSS of 86.77 (P < 0.00. The mechanical axis was significantly improved (P < 0.03 after surgery. No patient required blood transfusion and the average tourniquet time was 41 min. Conclusion: TKA using PSBs is useful and can be used in patients with retained hardware with good functional and radiological outcome.

  9. Types and properties of elastomer materials used in CANDU reactor

    Energy Technology Data Exchange (ETDEWEB)

    You, Ho Sik; Jeong, Jin Kon [Korea Atomic Energy Research Institute, Daeduk (Korea, Republic of)

    1996-05-01

    Properties and kinds of elastomer materials used in a CANDU power plant have been described. The elastomer materials have been used as a sealing material in the components f nuclear power plant since they have many excellent properties that can not be seen in other materials. It is very important to select proper elastomer materials used in the nuclear power plant are required to have resistance to temperature as well as radiation. According to the experimental results performed at some laboratories including the Chalk River Laboratory of AECL, elastomer materials with high resistance to temperature and radiation are Nitrile, Ethylene, Propylene and Butyl. These materials have been used in a lot of components of Wolsong unit 1 and Wolsong 2, 3 and 4 which are under elastomer material. Therefore, the studies on the standardization are currently under way to limit about 10 different kinds of elastomer materials to be used in the plant. 16 tabs., 1 fig., 12 refs. (Author) .new.

  10. Does the Watson-Jones or Modified Smith-Petersen Approach Provide Superior Exposure for Femoral Neck Fracture Fixation?

    Science.gov (United States)

    Lichstein, Paul M; Kleimeyer, John P; Githens, Michael; Vorhies, John S; Gardner, Michael J; Bellino, Michael; Bishop, Julius

    2018-04-24

    A well-reduced femoral neck fracture is more likely to heal than a poorly reduced one, and increasing the quality of the surgical exposure makes it easier to achieve anatomic fracture reduction. Two open approaches are in common use for femoral neck fractures, the modified Smith-Petersen and Watson-Jones; however, to our knowledge, the quality of exposure of the femoral neck exposure provided by each approach has not been investigated. (1) What is the respective area of exposed femoral neck afforded by the Watson-Jones and modified Smith-Petersen approaches? (2) Is there a difference in the ability to visualize and/or palpate important anatomic landmarks provided by the Watson-Jones and modified Smith-Petersen approaches? Ten fresh-frozen human pelvi underwent both modified Smith-Petersen (utilizing the caudal extent of the standard Smith-Petersen interval distal to the anterosuperior iliac spine and parallel to the palpable interval between the tensor fascia lata and the sartorius) and Watson-Jones approaches. Dissections were performed by three fellowship-trained orthopaedic traumatologists with extensive experience in both approaches. Exposure (in cm) was quantified with calibrated digital photographs and specialized software. Modified Smith-Petersen approaches were analyzed before and after rectus femoris tenotomy. The ability to visualize and palpate seven clinically relevant anatomic structures (the labrum, femoral head, subcapital femoral neck, basicervical femoral neck, greater trochanter, lesser trochanter, and medial femoral neck) was also recorded. The quantified area of the exposed proximal femur was utilized to compare which approach afforded the largest field of view of the femoral neck and articular surface for assessment of femoral neck fracture and associated femoral head injury. The ability to visualize and palpate surrounding structures was assessed so that we could better understand which approach afforded the ability to assess structures that

  11. Mammary and femoral hydatid cysts.

    Science.gov (United States)

    Shamim, Muhammad

    2010-08-01

    Hydatid cyst disease most commonly affects liver and lungs, but it can affect all viscera and soft tissues of the body. Simultaneous mammary and femoral hydatid cysts, without any other visceral involvement, are extremely rare. This is a case report of 25-years-old female, presenting with lump in left breast mimicking fibroadenoma and lump in right thigh mimicking fibroma. Both turned out to be hydatid cysts.

  12. Computational Modelling of Patella Femoral Kinematics During Gait Cycle and Experimental Validation

    Science.gov (United States)

    Maiti, Raman

    2016-06-01

    The effect of loading and boundary conditions on patellar mechanics is significant due to the complications arising in patella femoral joints during total knee replacements. To understand the patellar mechanics with respect to loading and motion, a computational model representing the patella femoral joint was developed and validated against experimental results. The computational model was created in IDEAS NX and simulated in MSC ADAMS/VIEW software. The results obtained in the form of internal external rotations and anterior posterior displacements for a new and experimentally simulated specimen for patella femoral joint under standard gait condition were compared with experimental measurements performed on the Leeds ProSim knee simulator. A good overall agreement between the computational prediction and the experimental data was obtained for patella femoral kinematics. Good agreement between the model and the past studies was observed when the ligament load was removed and the medial lateral displacement was constrained. The model is sensitive to ±5 % change in kinematics, frictional, force and stiffness coefficients and insensitive to time step.

  13. Geometry of the Valgus Knee: Contradicting the Dogma of a Femoral-Based Deformity.

    Science.gov (United States)

    Eberbach, Helge; Mehl, Julian; Feucht, Matthias J; Bode, Gerrit; Südkamp, Norbert P; Niemeyer, Philipp

    2017-03-01

    Realignment osteotomies of valgus knee deformities are usually performed at the distal femur, as valgus alignment is considered to be a femoral-based deformity. This dogma, however, has not been proven in a large patient population. Valgus malalignment may also be caused by a tibial deformity or a combined tibial and femoral deformity. The purposes of this study were (1) to analyze the coronal geometry of patients with valgus malalignment and identify the location of the underlying deformity and (2) to investigate the proportion of cases that require realignment osteotomy at the tibia, the femur, or both locations to avoid an oblique joint line. Cross-sectional study; Level of evidence, 3. The analysis included 420 standing full-leg radiographs of patients with valgus malalignment (mechanical femorotibial angle [mFTA], ≥4°). A systematic analysis of the coronal leg geometry was performed including the mFTA, mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), and joint-line convergence angle (JLCA). The localization of the deformity was determined according to the malalignment test described by Paley, and patients were assigned to 1 of 4 groups: femoral-based valgus deformity, tibial-based valgus deformity, femoral- and tibial-based valgus deformity, or intra-articular/ligamentary-based valgus deformity. Subsequently, the ideal osteotomy site was identified with the goal of a postoperative change of the joint line of two different maximum values, ±2° and ±4°, from its physiological varus position of 3°. Measurements of the coronal alignment revealed a mean (±SD) mFTA of 7.4° ± 4.3° (range, 4°-28.2°). The mean mLDFA and mean mMPTA were 84.8° ± 2.4° and 90.9° ± 2.6°, respectively. The mean JLCA was 1.2° ± 3.1°. The majority (41.0%) of valgus deformities were tibial based, 23.6% were femoral based, 26.9% were femoral and tibial based, and 8.6% were intra-articular/ligamentary based. To achieve a

  14. International Nuclear Safety Center database on thermophysical properties of reactor materials

    International Nuclear Information System (INIS)

    Fink, J.K.; Sofu, T.; Ley, H.

    1997-01-01

    The International Nuclear Safety Center (INSC) database has been established at Argonne National Laboratory to provide easily accessible data and information necessary to perform nuclear safety analyses and to promote international collaboration through the exchange of nuclear safety information. The INSC database, located on the World Wide Web at http://www.insc.anl.gov, contains critically assessed recommendations for reactor material properties for normal operating conditions, transients, and severe accidents. The initial focus of the database is on thermodynamic and transport properties of materials for water reactors. Materials that are being included in the database are fuel, absorbers, cladding, structural materials, coolant, and liquid mixtures of combinations of UO 2 , ZrO 2 , Zr, stainless steel, absorber materials, and concrete. For each property, the database includes: (1) a summary of recommended equations with uncertainties; (2) a detailed data assessment giving the basis for the recommendations, comparisons with experimental data and previous recommendations, and uncertainties; (3) graphs showing recommendations, uncertainties, and comparisons with data and other equations; and (4) property values tabulated as a function of temperature

  15. The Study of the Composite Material Go/CF/PTFE Tribological Property

    Directory of Open Access Journals (Sweden)

    Wang Li-hu

    2017-01-01

    Full Text Available In this paper, the composite material Go/CF/PTFE tribological property was studied. The test of its mechanical property, and the fabrication of the filled PTEE composite material sample which is based on the technology of cold press molding and sinter molding proved that adding Go and CF moderately to the composite material was an efficient way to improve its mechanical property. Meanwhile the process of friction and wear trial and SEM analysis results of the micro-structure of wear pattern proved that the addition of the Go and CF tremendously improved the anti-wear property and that after the addition the plowing effect which took place on the material surface would turn into a kind of mixed wear effect that includes plowing effect and fatigue wear. Working as pinning and bridging, the Go which distributing uniformly in the matrix was able to improve the resistance and substantially resisted the crack propagation, therefore to a certain degree enhanced the intensity of composite material and prolong its lifespan.

  16. Radiation exposure and patient experience during percutaneous coronary intervention using radial and femoral artery access

    International Nuclear Information System (INIS)

    Geijer, Haakan; Persliden, Jan

    2004-01-01

    The aim of this study was to evaluate radiation dose and patient discomfort/pain in radial artery access vs femoral artery access in percutaneous coronary intervention (PCI). Dose-area product (DAP) was measured non-randomised for 114 procedures using femoral access and for 55 using radial access. The patients also responded to a questionnaire concerning discomfort and pain during and after the procedure. The mean DAP was 69.8 Gy cm 2 using femoral access and 70.5 Gy cm 2 using radial access. Separating the access site from confounding factors with a multiple regression, there was a 13% reduction in DAP when using radial access (p=0.038). Procedure times did not differ (p=0.81). Bed confinement was much longer in the femoral access group (448 vs 76 min, p=0.000). With femoral access, there was a significantly higher patient grading for chest (p=0.001) and back pain (p=0.003) during the procedure and for access site (p=0.000) and back pain (p=0.000) after the procedure. Thirty-two femoral access patients (28%) were given morphine-type analgesics in the post-procedure period compared to three radial access patients (5%, p=0.001). DAP does not increase when using radial instead of femoral access and the patients grade discomfort and pain much lower when using radial access. Radial access is thus beneficial to use. (orig.)

  17. No difference in in vivo polyethylene wear particles between oxidized zirconium and cobalt-chromium femoral component in total knee arthroplasty.

    Science.gov (United States)

    Minoda, Yukihide; Hata, Kanako; Iwaki, Hiroyoshi; Ikebuchi, Mitsuhiko; Hashimoto, Yusuke; Inori, Fumiaki; Nakamura, Hiroaki

    2014-03-01

    Polyethylene wear particle generation is one of the most important factors affecting mid- to long-term results of total knee arthroplasties. Oxidized zirconium was introduced as a material for femoral components to reduce polyethylene wear generation. However, an in vivo advantage of oxidized zirconium on polyethylene wear particle generation is still controversial. The purpose of this study was to compare in vivo polyethylene wear particles between oxidized zirconium total knee prosthesis and conventional cobalt-chromium (Co-Cr) total knee prosthesis. Synovial fluid was obtained from the knees of 6 patients with oxidized zirconium total knee prosthesis and from 6 patients with conventional cobalt-chromium (Co-Cr) total knee prosthesis 12 months after the operation. Polyethylene particles were isolated and examined using a scanning electron microscope and image analyser. Total number of particles in each knee was 3.3 ± 1.3 × 10(7) in the case of oxidized zirconium (mean ± SD) and 3.4 ± 1.2 × 10(7) in that of Co-Cr (n.s.). The particle size (equivalent circle diameter) was 0.8 ± 0.3 μm in the case of oxidized zirconium and 0.6 ± 0.1 μm in that of Co-Cr (n.s.). The particle shape (aspect ratio) was 1.4 ± 0.0 in the case of oxidized zirconium and 1.4 ± 0.0 in that of metal Co-Cr (n.s). Although newly introduced oxidized zirconium femoral component did not reduce the in vivo polyethylene wear particles in early clinical stage, there was no adverse effect of newly introduced material. At this moment, there is no need to abandon oxidized zirconium femoral component. However, further follow-up of polyethylene wear particle generation should be performed to confirm the advantage of the oxidized zirconium femoral component. Therapeutic study, Level III.

  18. Avascular Necrosis of the Femoral Head: Are Any Genes Involved?

    Science.gov (United States)

    Pouya, Farzaneh; Kerachian, Mohammad Amin

    2015-01-01

    Avascular necrosis of the femoral head (ANFH) is a pathologic process that results from interruption of blood supply to the femur bone resulting in the death of bone cells and collapse of the femoral head. Nontraumatic ANFH continues to be a significant challenge to orthopedic surgeons. While the exact mechanisms remain elusive, many new insights have emerged from research in the last decade that has given us a clearer picture of the pathogenesis of nontraumatic ANFH. Progression to the end stage of ANFH appears to be related to five main mechanisms: hypercoagulable conditions, angiogenesis suppressions, hyperadipogenesis, heritable states, and switching the bone remodelling into bone resorption. Researchers have been examining the pathogenic mechanisms of ANFH but none of these theories have been firmly confirmed although some appear more plausible than the others. All of these factors can switch bone remodelling into bone resorption, which can further lead to ANFH progression ending up to femoral head collapse. PMID:26213697

  19. Material Properties Analysis of Structural Members in Pumpkin Balloons

    Science.gov (United States)

    Sterling, W. J.

    2003-01-01

    The efficient design, service-life qualification, and reliability predictions for lightweight aerospace structures require careful mechanical properties analysis of candidate structural materials. The demand for high-quality laboratory data is particularly acute when the candidate material or the structural design has little history. The pumpkin-shaped super-pressure balloon presents both challenges. Its design utilizes load members (tendons) extending from apex to base around the gas envelope to achieve a lightweight structure. The candidate tendon material is highly weight-efficient braided HM cord. Previous mechanical properties studies of Zylon have focused on fiber and yarn, and industrial use of the material in tensile applications is limited. For high-performance polymers, a carefully plamed and executed properties analysis scheme is required to ensure the data are relevant to the desired application. Because no directly-applicable testing standard was available, a protocol was developed based on guidelines fiom professional and industry organizations. Due to the liquid-crystalline nature of the polymer, the cord is very stiff, creeps very little, and does not yield. Therefore, the key material property for this application is the breaking strength. The pretension load and gauge length were found to have negligible effect on the measured breaking strength over the ranges investigated. Strain rate was found to have no effect on breaking strength, within the range of rates suggested by the standards organizations. However, at the lower rate more similar to ULDB operations, the strength was reduced. The breaking strength increased when the experiment temperature was decreased from ambient to 183K which is the lowest temperature ULDB is expected to experience. The measured strength under all test conditions was well below that resulting from direct scale-up of fiber strength based on the manufacturers data. This expected result is due to the effects of the

  20. Material Property Measurement in Hostile Environments using Laser Acoustics

    International Nuclear Information System (INIS)

    Ken L. Telschow

    2004-01-01

    Acoustic methods are well known and have been used to measure various intrinsic material properties, such as, elastic coefficients, density, crystal axis orientation, microstructural texture, and residual stress. Extrinsic properties, such as, dimensions, motion variables or temperature are also readily determined from acoustic methods. Laser acoustics, employing optical generation and detection of elastic waves, has a unique advantage over other acoustic methods-it is noncontacting, uses the sample surface itself for transduction, requires no couplant or invasive sample surface preparation and can be utilized in any hostile environment allowing optical access to the sample surface. In addition, optical generation and detection probe beams can be focused to the micron scale and/or shaped to alter the transduction process with a degree of control not possible using contact transduction methods. Laser methods are amenable to both continuous wave and pulse-echo measurements and have been used from Hz to 100's of GHz (time scales from sec to psec) and with amplitudes sufficient to fracture materials. This paper shall review recent applications of laser acoustic methods to determining material properties in hostile environments that preclude the use of contacting transduction techniques. Example environments include high temperature (>1000C) sintering and molten metal processing, thin film deposition by plasma techniques, materials moving at high velocity during the fabrication process and nuclear high radiation regions. Recent technological advances in solid-state lasers and telecommunications have greatly aided the development and implementation of laser acoustic methods, particularly at ultra high frequencies. Consequently, laser acoustic material property measurements exhibit high precision and reproducibility today. In addition, optical techniques provide methods of imaging acoustic motion that is both quantitative and rapid. Possible future directions for laser

  1. High Temperature Thermoelectric Properties of ZnO Based Materials

    DEFF Research Database (Denmark)

    Han, Li

    of the dopants and dopant concentrations, a large power factor was obtainable. The sample with the composition of Zn0.9Cd0.1Sc0.01O obtained the highest zT ∼0.3 @1173 K, ~0.24 @1073K, and a good average zT which is better than the state-of-the-art n-type thermoelectric oxide materials. Meanwhile, Sc-doped Zn......This thesis investigated the high temperature thermoelectric properties of ZnO based materials. The investigation first focused on the doping mechanisms of Al-doped ZnO, and then the influence of spark plasma sintering conditions on the thermoelectric properties of Al, Ga-dually doped Zn......O. Following that, the nanostructuring effect for Al-doped ZnO was systematically investigated using samples with different microstructure morphologies. At last, the newly developed ZnCdO materials with superior thermoelectric properties and thermal stability were introduced as promising substitutions...

  2. A Quantitative Property-Property Relationship for the Internal Diffusion Coefficients of Organic Compounds in Solid Materials

    DEFF Research Database (Denmark)

    Huang, Lei; Fantke, Peter; Jolliet, Olivier

    2017-01-01

    of chemical-material combinations. This paper develops and evaluates a quantitative property-property relationship (QPPR) to predict diffusion coefficients for a wide range of organic chemicals and materials. We first compiled a training dataset of 1103 measured diffusion coefficients for 158 chemicals in 32......Indoor releases of organic chemicals encapsulated in solid materials are major contributors to human exposures and are directly related to the internal diffusion coefficient in solid materials. Existing correlations to estimate the diffusion coefficient are only valid for a limited number...... consolidated material types. Following a detailed analysis of the temperature influence, we developed a multiple linear regression model to predict diffusion coefficients as a function of chemical molecular weight (MW), temperature, and material type (adjusted R2 of 0.93). The internal validations showed...

  3. A COMPARATIVE STUDY OF PROXIMAL FEMUR LOCKING COMPRESSION PLATE VERSUS PROXIMAL FEMORAL NAILING IN THE MANAGEMENT OF COMMINUTED TROCHANTERIC AND SUBTROCHANTERIC FRACTURE

    Directory of Open Access Journals (Sweden)

    Satish Koti

    2016-11-01

    Full Text Available BACKGROUND Fractures of proximal femur and hip are relatively common injuries in elderly individuals constituting 11.6% of total fractures. The latest implant for management of intertrochanteric fracture is Proximal Femoral Locking Compression Plate (PF-LCP. In this study, we compare the clinical outcome of fractures treated by proximal femoral nail with that of proximal femur locking compression plate. MATERIALS AND METHODS The present study consists of 24 elderly patients of peritrochanteric factures of femur satisfying the inclusion criteria who were treated with PF-LCP or PFN in Department of Orthopaedics, S.V.R.R.G.G.H, Tirupati, during a period between December 2013 to October 2015. RESULTS 24 cases were treated with PF-LCP or PFN in a randomised pattern who satisfied inclusion criteria. Intraoperative complication were found to be more with PF-LCP in contrast to PFN. Postoperative rehabilitation was easier with PFN though not statistically significant functional and anatomical outcomes were found to be better with PFN. CONCLUSION Both PFN and PF-LCP have good effectiveness in the treatment of intertrochanteric fractures with the lateral unsubstantial femoral wall in the elderly patients. Each has its own advantages and disadvantages. Further studies with large number of patients and long-term follow up is needed to determine the optimal implant for the internal fixation of comminuted pertrochanteric femoral fractures.

  4. A FUNCTIONAL EVALUATION STUDY OF DISTAL FEMORAL FRACTURES FIXED WITH DISTAL FEMORAL LOCKING PLATE

    Directory of Open Access Journals (Sweden)

    Manikumar C. J

    2017-04-01

    Full Text Available BACKGROUND Fractures of the distal femur present considerable challenges in management. Older patients especially women sustain fractures due to osteoporosis. Supracondylar fractures of femur have a bimodal distribution. They account for 6% of all femur fractures and 31% if hip fractures were excluded. Nearly, 50% of distal femur intra-articular fractures are open fractures. Before 1970, most supracondylar fractures were treated nonoperatively; however, difficulties were often encountered including persistent angulatory deformity, knee joint incongruity, loss of knee motion and delayed mobilisation. The trend of open reduction and internal fixation has become evident in recent years with good results being obtained with AO blade plate, dynamic condylar screw, intramedullary supracondylar nail and locking compression plate. Elderly patients and osteoporosis pose difficulty in treating intra-articular fractures of the lower end of femur. Loss of stable fixation is of great concern in these cases. Hence, locking compression plate use has an advantage in these patients. MATERIALS AND METHODS In this study, 20 patients with closed fracture of distal femur were studied. All the cases were treated at the Department of Orthopaedics, Rangaraya Medical College/Government General Hospital, Kakinada, Andhra Pradesh, between November 2013 and November 2015. The method used for fracture fixation was open reduction and internal fixation with distal femoral locking plate. The duration of follow up ranged from 3 months to 24 months. All the fractures in this series were posttraumatic. The patients were functionally evaluated with Neer’s scoring system. 1 RESULTS Twenty distal femoral fractures were treated with distal femoral locking plates. 15 patients were males and 5 patients were females. The median age was 47 years ranging from 28-70 years. 16 of the fractures were caused by road traffic accidents and 2 were due to fall, 2 were due to assault. 12 patients

  5. What is the optimal alignment of the tibial and femoral components in knee arthroplasty?

    DEFF Research Database (Denmark)

    Gromov, Kirill; Korchi, Mounim; Thomsen, Morten G

    2014-01-01

    of positioning on survival and functional outcome was considered. Results - Many definitions exist when evaluating placement of femoral and tibial components. Implant alignment plays a role in both survival and functional outcome following primary TKA, as component malalignment can lead to increased failure......Background - Surgeon-dependent factors such as optimal implant alignment are thought to play a significant role in outcome following primary total knee arthroplasty (TKA). Exact definitions and references for optimal alignment are, however, still being debated. This overview of the literature...... describes different definitions of component alignment following primary TKA for (1) tibiofemoral alignment in the AP plane, (2) tibial and femoral component placement in the AP plane, (3) tibial and femoral component placement in the sagittal plane, and (4) rotational alignment of tibial and femoral...

  6. Autologous Platelet Concentrates as Treatment for Avascular Necrosis of Femoral Head in a Dog.

    Science.gov (United States)

    Parra, Estefanía; Vergara, Andrea; Silva, Raúl F

    2017-03-01

    Avascular necrosis of the femoral head is a developmental disturbance that generally affects young dogs of small breeds and produces ischemic necrosis of the femoral head resulting in an incongruous and malformed joint. The most common treatment is the excisional arthroplasty of the head and femoral neck. The aim of this study is to describe the treatment of avascular necrosis in a Yorkshire dog using intra-articular injections of autologous platelet concentrate. Evaluations were made at 0, 15, 30, 60, and 120 days of treatment, describing the following parameters: clinical gait analysis, perimetry, goniometry, and radiographic evaluations. The results obtained in this case suggest that the autologous platelet concentrate may be an alternative for the treatment of avascular necrosis of the femoral head in dogs. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Who are we missing? Too few skeletal surveys for children with humeral and femoral fractures

    International Nuclear Information System (INIS)

    Shelmerdine, S.C.; Das, R.; Ingram, M.D.; Negus, S.

    2014-01-01

    Aim: To determine the potential shortfall in skeletal survey referral for children presenting with an acute non-supracondylar humeral or femoral fracture. Materials and methods: Plain radiograph reports were reviewed retrospectively using the radiology information system database over a 5 year study period (May 2008–2013) in children under 18 months of age who presented with an acute fracture. Subsequent skeletal survey referral was used as a surrogate marker for further investigation of child abuse. Application of robust meta-analysis derived probability data regarding likelihood of child abuse as a cause of non-supracondylar humeral or femoral fracture was applied. An estimation of the expected number of cases of abuse, with shortfall in skeletal survey referrals, was then calculated. Results: There were 288 fractures in 281 children. Three children presented with multiple fractures and were considered separately in the present data. The mean patient age was 10.5 months. Nine (3%) non-supracondylar humeral fractures were identified of which four cases may have been due to non-accidental injury (NAI). One (11%) of these patients was referred for a skeletal survey indicating a potential shortfall of three referrals. Twenty-five (9%) femoral fractures were identified of which 13 cases may have been due to NAI, with six (24%) referrals for skeletal surveys generated. This indicates a potential shortfall of seven referrals. Conclusion: The present study serves as a current analysis of practice within a tertiary paediatric referral centre. There appeared to be local under-investigation of NAI. Improved child protection education and awareness programmes have now been introduced. - Highlights: • Long bone fractures in non-ambulatory children carry high probability for child abuse. • Suspicion for child abuse should trigger a referral for a skeletal survey. • We examine the potential shortfall in skeletal survey referrals in such patients. • Only 11% and 24% of

  8. Analgesic effect of continuous femoral nerve block combined with infiltration anesthesia after total knee replacement

    OpenAIRE

    Jian-Guo Tan

    2016-01-01

    Objective: To study the analgesic effect of continuous femoral nerve block combined with infiltration anesthesia after total knee replacement. Methods: Patients who received unilateral total knee replacement in our hospital from May 2012 to August 2015 were included for study and randomly divided into experimental group who received continuous femoral nerve block combined with infiltration anesthesia and control group who received continuous femoral nerve block, and then the co...

  9. Evaluation in femoral neck fracture scintimetry: modes of region of interest selection and influence on results

    Energy Technology Data Exchange (ETDEWEB)

    Holmberg, S.; Mesko, L.; Stroemqvist, B.; Thorngren, K.G.

    1985-04-01

    Different sized ROIs within the femoral head and different modes of calculation were used in (/sup 99m/Tc)MDP scintimetry after femoral neck fracture. In preoperative scintimetry, correction for increased trochanteric uptake gave the best discrimination, whereas in postoperative scintimetry the direct ratio fractured/intact femoral head was superior. The change in ROI size had little influence.

  10. Evaluation in femoral neck fracture scintimetry: modes of region of interest selection and influence on results

    International Nuclear Information System (INIS)

    Holmberg, S.; Mesko, L.; Stroemqvist, B.; Thorngren, K.G.

    1985-01-01

    Different sized ROIs within the femoral head and different modes of calculation were used in [/sup 99m/Tc]MDP scintimetry after femoral neck fracture. In preoperative scintimetry, correction for increased trochanteric uptake gave the best discrimination, whereas in postoperative scintimetry the direct ratio fractured/intact femoral head was superior. The change in ROI size had little influence

  11. Properties of nanoclay PVA composites materials

    Directory of Open Access Journals (Sweden)

    Mohamed H. M. Ali

    2012-03-01

    Full Text Available Polyvinyl alcohol (PVA/ Na-rich Montmorillonite (MMT nanocomposites were prepared using solution method to create polymer-clay nanocomposite (PCN material. The PCN material was studied using X-ray diffraction (XRD, demonstrating polymer-clay intercalation that has a high d-spacing (lower diffraction angles in the PCN XRD pattern, compared to the pure MMT clay XRD pattern, which has a low d-spacing (high diffraction angles. The nano-scanning electron microscope (NSEM was used to study the morphological image of the PVA, MMT and PCN materials. The results showed that intercalation that took place between the PVA and MMT produced the PCN material. The mechanical properties of the pure PVA and the intercalated polymer material were studied. It was found that the small amount of MMT clay made the tensile modulus and percentage of the total elongation of the nano-composite significantly higher than the pure PVA polymer value, due to polymer-clay intercalation. The thermal stability of the intercalated polymer has been studied using thermal analytical techniques such as thermogravimetric analysis (TGA and differential scanning calorimetry (DSC. The results showed that the PCN material is more thermally stable than the pure PVA polymer.

  12. Removal of a broken guide wire entrapped in a fractured femoral neck

    Directory of Open Access Journals (Sweden)

    ZHU Qing-hua

    2013-08-01

    Full Text Available 【Abstract】Guide wire plays an important role in the fixation of femoral neck fracture with dynamic hip screw (DHS. Breakage of a guide wire during operation is a very rare condition. We met such a dilemma in DHS fixation of a 54-year-old male patient who sustained Garden type IV frac-ture of the right femoral neck. The distal end of the guide wire broke and was entrapped in the fractured femoral neck. We tried to get the broken part out by a cannulated drill. Reaming was started with the cannulated drill slowly rotat-ing around the guide K-wire until the reamer fully contained the target under fluoroscope. A bone curette was used to get the broken wire out but failed, so we had to use the cannuated drill to dredge this bone tunnel. Finally the bro-ken wire end was taken out, mixed with blood and bone fragments. Through the existing drilling channel, DHS fixa-tion was easily finished. The patient had an uneventful re-covery without avascular necrosis of femoral head or non-union of the fracture at one year’s follow-up. A few methods can be adopted to deal with the broken guide wire. The way used in our case is less invasive but technically challenging. When the guide wire is properly positioned, this method is very practical and useful. Key words: Femoral neck fractures; Bones wires; Complications

  13. Coupling failure between stem and femoral component in a constrained revision total knee arthroplasty.

    LENUS (Irish Health Repository)

    Butt, Ahsan Javed

    2013-02-01

    Knee revision using constrained implants is associated with greater stresses on the implant and interface surfaces. The present report describes a case of failure of the screw coupling between the stem and the femoral component. The cause of the failure is surmised with outline of the treatment in this case with extensive femoral bone loss. Revision implant stability was augmented with the use of a cemented femoral stem, screw fixation and the metaphyseal sleeve of an S-ROM modular hip system (DePuy international Ltd).

  14. Femoral access in 100 consecutive subarachnoid hemorrhage patients: the "craniotomy" of endovascular neurosurgery

    Directory of Open Access Journals (Sweden)

    Huang Judy

    2010-11-01

    Full Text Available Abstract Background Femoral access is a fundamental element of catheter-based cerebral angiography. Knowledge of location of the common femoral artery (CFA bifurcation is important as the risk of retroperitoneal bleeding is increased if the puncture is superior to the inguinal ligament and there is an increased risk of thrombosis and arteriovenous fistula formation if the puncture is distal into branch vessels. We sought to characterize the location of the CFA bifurcation along with the presence of significant atherosclerosis or iliac tortuosity in a contemporary series of subarachnoid hemorrhage (SAH patients. Findings The records of a prospective single-center aneurysm database were reviewed to identify 100 consecutive SAH patients. Using an oblique femoral arteriogram, the presence of significant atherosclerosis, iliac tortuosity, and the CFA bifurcation were assessed. The CFA bifurcation was graded according to its position with respect to the femoral head: below (grade 1, lower half (grade 2, and above the upper half (grade 3. We found a CFA bifurcation grade 1 in 50 patients (50%, mean age 51.2 years, grade 2 in 40 patients (40%, mean age 55.5 years, and grade 3 in 10 patients (10%, mean age 58.2 years. Whereas 30 of 90 patients with CFA grades I or II were male (33%, only 10% with grade 3 were male (1 of 10, p = 0.12. Mean age for significant atherosclerosis was 65.5 +/- 2.6 years versus 50.9 +/- 1.6 years (p Conclusions Although a requisite element of endovascular treatment in SAH patients, femoral access can be complicated by a high common femoral artery bifurcation and the presence of atherosclerotic disease and/or iliac artery tortuosity. In this study, we found a grade 3 (above the femoral head CFA bifurcation in 10% patients, with 90% of these patients being female. We also found the presence of atherosclerotic disease and iliac tortuosity to be significantly more likely in patients older than 65 years of age.

  15. Solar Sail Material Performance Property Response to Space Environmental Effects

    Science.gov (United States)

    Edwards, David L.; Semmel, Charles; Hovater, Mary; Nehls, Mary; Gray, Perry; Hubbs, Whitney; Wertz, George

    2004-01-01

    The National Aeronautics and Space Administration's (NASA) Marshall Space Flight Center (MSFC) continues research into the utilization of photonic materials for spacecraft propulsion. Spacecraft propulsion, using photonic materials, will be achieved using a solar sail. A solar sail operates on the principle that photons, originating from the sun, impart pressure to the sail and therefore provide a source for spacecraft propulsion. The pressure imparted to a solar sail can be increased, up to a factor of two, if the sun-facing surface is perfectly reflective. Therefore, these solar sails are generally composed of a highly reflective metallic sun-facing layer, a thin polymeric substrate and occasionally a highly emissive back surface. Near term solar sail propelled science missions are targeting the Lagrange point 1 (Ll) as well as locations sunward of L1 as destinations. These near term missions include the Solar Polar Imager and the L1 Diamond. The Environmental Effects Group at NASA s Marshall Space Flight Center (MSFC) continues to actively characterize solar sail material in preparation for these near term solar sail missions. Previous investigations indicated that space environmental effects on sail material thermo-optical properties were minimal and would not significantly affect the propulsion efficiency of the sail. These investigations also indicated that the sail material mechanical stability degrades with increasing radiation exposure. This paper will further quantify the effect of space environmental exposure on the mechanical properties of candidate sail materials. Candidate sail materials for these missions include Aluminum coated Mylar[TM], Teonex[TM], and CPl (Colorless Polyimide). These materials were subjected to uniform radiation doses of electrons and protons in individual exposures sequences. Dose values ranged from 100 Mrads to over 5 Grads. The engineering performance property responses of thermo-optical and mechanical properties were

  16. Relationship of material properties to seismic coupling. Part I. Shock wave studies of rock and rock-like materials

    International Nuclear Information System (INIS)

    Larson, D.B.; Rodean, H.C.

    1975-01-01

    Our research seeks an understanding of the relationship of material properties to explosive-energy coupling in various earth media by integrating experimental observations with computer calculational models to obtain a predictive capability. The procedure chosen consists of: first, selecting materials exhibiting interesting values of the properties that are believed to control coupling; second, experimentally determining material behavior under various types of loading and unloading; third, development of constitutive relationships; fourth, adapting these constitutive relationships to computer calculational models; and fifth, verifying the calculational models through comparison with small-scale and field high-strain-rate experiments. The object of this report is to present the shock-wave data and to make a preliminary evaluation of the results in terms of material properties, coupling, and their interactions. (U.S.)

  17. Femoral sizing in total knee arthroplasty is rotation dependant.

    Science.gov (United States)

    Koninckx, Angelique; Deltour, Arnaud; Thienpont, Emmanuel

    2014-12-01

    The mismatch between the medio-lateral (ML) and the antero-posterior (AP) size of femoral components in total knee arthroplasty (TKA) has been linked to gender, ethnicity, morphotype and height differences in patients. The hypothesis of this study was that the AP size measurement of a femoral component increases with more external rotation in posterior referencing TKA. During a 2-year period, 201 patients were included in this prospective study. The AP distance of the distal femur was measured with an AP sizer of the Vanguard (Biomet, Warsaw, US) knee system. This AP sizer allows to dial in external rotation by 1° increments and to determine the femoral size with an anterior boom. AP size was noted at 0°, 3° and 5° of external rotation and then compared for ML matching. Antero-posterior and corresponding ML sizes match perfectly for the Vanguard at 0° of external rotation and a central boom position on the anterior femoral surface. Then, the anterior boom was positioned on the antero-lateral cortex and the AP size increased a mean (SD) 1 (0.5) mm. With 3° of external rotation, the AP size increased a mean (SD) 2.3 (0.4) mm and for 5° a mean (SD) 3.8 (0.3) mm (P external rotation that is dialled in during surgery. Since these parameters vary case per case, the availability of narrow components offers more surgical options to the surgeon and its importance extends beyond the gender aspect allowing different amounts of external rotation to be used without ML overhang. II.

  18. Does Tranexamic Acid Reduce Bleeding during Femoral Fracture Operation?

    Directory of Open Access Journals (Sweden)

    Mohammad Haghighi

    2017-03-01

    Full Text Available Background:Proximal Femoral shaft fractures are commonly associated with marked blood loss which can lead topostoperative acute anemia and some other complications.Tranexamic acid (TA is an antifibrinolytic medication that reduces intra-and postoperative blood loss and transfusionrequirements during some elective surgeries (1-3.The aim of this study is to evaluate the effect of intravenous Tranexamic acid (TA on intraoperative blood loss and asubsequent need for transfusion in patients who were undergoing surgery for femoral shaft fractures in trauma setting.Methods:Thirty-eight ASA grade I-II patients undergoing proximal femoral shaft fracture surgery with intra medullarynailing were included in this double blind randomized controlled clinical trial. They were allocated into two groups. GroupI, the intervention group with eighteen patients received 15 mg/kg (TA via intravenous infusion before surgical incision.Patients in the placebo group received an identical volume of normal saline.Hemoglobin level was measured four hours before and after the surgeries. Postoperative blood loss and hemoglobinchange as well as transfusion rates and volumes were compared between the two groups.Results:Mean Percentage fall in hemoglobin after surgery were 1.75±0.84 and 2.04±1.9 in the study and placebo groups,respectively (P=0.570. Hemoglobin loss was higher in the placebo group. Transfusion rates was lower in TA group(5.6% compared to the placebo group (30% (P=0.06. No significant difference in The Allowable Blood Loss during thesurgery was found between the two groups (P=0.894.Conclusion:Preoperative treatment with TA reduces postoperative blood loss and the need for blood transfusion duringtraumatic femoral fracture operation.

  19. Femoral Prosthesis Infection by Rhodotorula mucilaginosa▿

    Science.gov (United States)

    Savini, Vincenzo; Sozio, Federica; Catavitello, Chiara; Talia, Marzia; Manna, Assunta; Febbo, Fabio; Balbinot, Andrea; Di Bonaventura, Giovanni; Piccolomini, Raffaele; Parruti, Giustino; D'Antonio, Domenico

    2008-01-01

    This case report is a case history of a femoral prosthesis infection caused by Rhodotorula mucilaginosa in a human immunodeficiency virus patient. Though the pathogenicity of this organism for bone tissue has been previously reported, this is the first reported case of an orthopedic prosthesis infection by this species of the genus Rhodotorula. PMID:18753353

  20. Material property determination of the lining layers of a versatile helmet

    Directory of Open Access Journals (Sweden)

    Kottner Radek

    2018-01-01

    Full Text Available This paper deals with material property identification of a helmet lining consisting of an outer layer of an expanded polystyrene (EPS and inner layer of an open-closed cell foam (OCCF. A combined numerical simulation and experimental testing was used for the material property identification. Compression and drop tests were performed. The ABAQUS finite element commercial code was used for numerical simulations in which the OOCF was modelled as a rate dependent viscoelastic material, while the EPS as a crushable foam. The reaction force time histories coming from the numerical simulation and the experiment have been used as a criterion for material parameter determination. After the identification of the material properties, numerical drop-tests were used to study the behaviour of a plate and a conical composite OOCF and EPS liners to decide which of them suits more for the helmet.