WorldWideScience

Sample records for fast-shuttered intensified digital

  1. Ultra fast shutter driven by pulsed high current

    International Nuclear Information System (INIS)

    Zeng Jiangtao; Sun Fengju; Qiu Aici; Yin Jiahui; Guo Jianming; Chen Yulan

    2005-01-01

    Radiation simulation utilizing plasma radiation sources (PRS) generates a large number of undesirable debris, which may damage the expensive diagnosing detectors. An ultra fast shutter (UFS) driven by pulsed high current can erect a physical barrier to the slowly moving debris after allowing the passage of X-ray photons. The UFS consists of a pair of thin metal foils twisting the parallel axes in a Nylon cassette, compressed with an outer magnetic field, generated from a fast capacitor bank, discharging into a single turn loop. A typical capacitor bank is of 7.5 μF charging voltages varying from 30 kV to 45 kV, with corresponding currents of approximately 90 kA to 140 kA and discharging current periods of approximately 13.1 μs. A shutter closing time as fast as 38 microseconds has been obtained with an aluminium foil thickness of 100 micrometers and a cross-sectional area of 15 mm by 20 mm. The design, construction and the expressions of the valve-closing time of the UFS are presented along with the measured results of valve-closing velocities. (authors)

  2. Development of hard-seal gate valve and fast shutter for JT-60 neutral beam injectors

    International Nuclear Information System (INIS)

    Kuribayashi, S.; Minami, M.; Matsuoka, T.; Takeshita, K.; Morita, H.; Kuriyama, M.; Matsuda, S.; Shirakata, H.

    1983-01-01

    A 600 mm hard-seal valve and a fast shutter for the JT-60 Neutral Beam Injector were developed. The 600 mm hard-seal gate valve was fabricated and tested for 500 cycles at various temperatures of up to 250 0 C. In consequence, requirements of the endurance and vacuum tightness were satisfied. Major components of the fast shutter, i.e., swing action bellows and a high-speed pneumatic cylinder, were tested for 30,000 cycles, and their reliability was confirmed. Then the fast shutter was fabricated and tested. The test result indicated that the fast shutter fully satisfied the requirements of the molecular gas flow conductance and opening/closing speed. (author)

  3. Digital image intensifier radiography: A new diagnostic procedure in traumatology?

    International Nuclear Information System (INIS)

    Schmidt, C.; Deininger, H.K.; Staedtische Kliniken Darmstadt

    1990-01-01

    Digital image intensifier radiography visualises all traumatological changes of clinical relevance and can therefore be used in traumatology. However, the quality of conventional radiographs cannot be attained as yet. Radiation exposure is markedly reduced, and radiographs are obtained directly after exposure, so that this is an extremely rapid radiographic procedure. Images can be quickly transmitted by video cable to the relevant departments and working places. (orig.) [de

  4. Digital image intensifier radiography. One year's experience with a Polytron system

    International Nuclear Information System (INIS)

    Busch, H.P.; Lehmann, K.J.; Georgi, M.

    1989-01-01

    Since January 1988, digital image intensifier radiography has been used in the Clinic in Mannheim for DSA examinations and also in place of conventional screen/film examinations. Measurements have shown that compared with 100 mm and film/screen formats, digital radiography has poorer spatial resolution, but improved contrast resolution. The most common use of digital radiography was for examinations of the gastrointestinal tract. Using the demonstration of the mucosal fine relief pattern as a criterion of image quality, digital image intensifier radiography was able to achieve this satisfactorily. Comparison with film/screen examinations showed no loss of diagnostic information. Advantages of image intensifier radiography are reduced radiation dose, the possibility of postprocessing and economy. On the basis of 399 examinations, digital image intensifier radiography is now firmly established as part of the daily routine of the Mannheim Clinic. (orig.) [de

  5. Dynamic structural analysis of a fast shutter with a pneumatic actuator

    Energy Technology Data Exchange (ETDEWEB)

    Nemov, A., E-mail: nemov@compmechlab.com [St. Petersburg State Polytechnical University, Mechanics and Control Processes Department, Computational Mechanichs Laboratory, Polytechnicheskaya, 29, 195251 St. Petersburg (Russian Federation); Panin, A. [Institut fuer Energieforschung – Plasmaphysik, Forschungszentrum Juelich GmbH, Association EURATOM-FZJ, Member of Trilateral Euregio Cluster, 52425 Juelich (Germany); Borovkov, A.; Khovayko, M.; Zhuravskaya, E. [St. Petersburg State Polytechnical University, Mechanics and Control Processes Department, Computational Mechanichs Laboratory, Polytechnicheskaya, 29, 195251 St. Petersburg (Russian Federation); Krasikov, Yu.; Biel, W.; Neubauer, O. [Institut fuer Energieforschung – Plasmaphysik, Forschungszentrum Juelich GmbH, Association EURATOM-FZJ, Member of Trilateral Euregio Cluster, 52425 Juelich (Germany)

    2013-10-15

    Highlights: ► The dynamical simulations of cCXRS shutter with the use of the LS-DYNA explicit solver are presented and discussed. ► The results of the implicit and explicit solvers are compared; their pros and cons are pointed out. ► The simplified LS-DYNA shutter model for parametric studies has been built up and benchmarked against the full model. ► Oscillations of the shutter arms for different actuator flood times were studied. -- Abstract: Fast shutters can play important role for the ITER diagnostics. They protect diagnostic mirrors, especially the first ones closest to the plasma, between measurements, during dwell time and baking. In a nominal mode, as it is assumed, for example, for the ITER upper port plug no. 3 diagnostics, its shutter stays open ∼1 s and closed ∼21 s. The principal idea of the shutter concept is its ability to make fast transitions between the open and closed positions within fractions of second. A pneumatic actuator produces a pressure force to open or close the shutter. Due to the fast transient nature of the shutter operation, complicated by the parts’ impact interaction, the FE codes using the explicit time integration scheme have an advantage over the implicit ones. The shutter operation is modeled using the explicit solver. Since the shutter dynamic behavior strongly depends on the actuator flood time, different time profiles of the actuator pressure rise (drop) has been verified, including a fast transient with duration of ∼0.1 s. The results of the implicit and explicit solvers are compared. Their pros and cons are pointed out. The system damping, estimations of energy loss and ways to specify damping in FE models are discussed in the paper.

  6. Dynamic structural analysis of a fast shutter with a pneumatic actuator

    International Nuclear Information System (INIS)

    Nemov, A.; Panin, A.; Borovkov, A.; Khovayko, M.; Zhuravskaya, E.; Krasikov, Yu.; Biel, W.; Neubauer, O.

    2013-01-01

    Highlights: ► The dynamical simulations of cCXRS shutter with the use of the LS-DYNA explicit solver are presented and discussed. ► The results of the implicit and explicit solvers are compared; their pros and cons are pointed out. ► The simplified LS-DYNA shutter model for parametric studies has been built up and benchmarked against the full model. ► Oscillations of the shutter arms for different actuator flood times were studied. -- Abstract: Fast shutters can play important role for the ITER diagnostics. They protect diagnostic mirrors, especially the first ones closest to the plasma, between measurements, during dwell time and baking. In a nominal mode, as it is assumed, for example, for the ITER upper port plug no. 3 diagnostics, its shutter stays open ∼1 s and closed ∼21 s. The principal idea of the shutter concept is its ability to make fast transitions between the open and closed positions within fractions of second. A pneumatic actuator produces a pressure force to open or close the shutter. Due to the fast transient nature of the shutter operation, complicated by the parts’ impact interaction, the FE codes using the explicit time integration scheme have an advantage over the implicit ones. The shutter operation is modeled using the explicit solver. Since the shutter dynamic behavior strongly depends on the actuator flood time, different time profiles of the actuator pressure rise (drop) has been verified, including a fast transient with duration of ∼0.1 s. The results of the implicit and explicit solvers are compared. Their pros and cons are pointed out. The system damping, estimations of energy loss and ways to specify damping in FE models are discussed in the paper

  7. X-ray image intensifier/television systems for digital skeletal radiography

    International Nuclear Information System (INIS)

    Rowlands, J.A.; Hynes, D.M.; Edmonds, E.W.; Porter, A.J.; Toth, B.J.

    1987-01-01

    The imaging criteria for skeletal radiography (high resolution and low noise) relevant to the use of x-ray image intensifier/TV digital systems are discussed. It is shown from the modulation transfer function (MTF), noise, and phantom evaluations that conventional x-ray image intensifiers in conjunction with a 1,000-line Plumbicon or Saticon TV camera are in most respects suitable for skeletal radiography. The optimum focal spot size depends on a trade-off with motion blurring through the x-ray exposure time and so is a function of the clinical problem. Since the skeletal system is readily immobilized, a 0.3-mm focal spot size is nearly optimum

  8. Time-resolved spectroscopy using a chopper wheel as a fast shutter

    International Nuclear Information System (INIS)

    Wang, Shicong; Wendt, Amy E.; Boffard, John B.; Lin, Chun C.

    2015-01-01

    Widely available, small form-factor, fiber-coupled spectrometers typically have a minimum exposure time measured in milliseconds, and thus cannot be used directly for time-resolved measurements at the microsecond level. Spectroscopy at these faster time scales is typically done with an intensified charge coupled device (CCD) system where the image intensifier acts as a “fast” electronic shutter for the slower CCD array. In this paper, we describe simple modifications to a commercially available chopper wheel system to allow it to be used as a “fast” mechanical shutter for gating a fiber-coupled spectrometer to achieve microsecond-scale time-resolved optical measurements of a periodically pulsed light source. With the chopper wheel synchronized to the pulsing of the light source, the time resolution can be set to a small fraction of the pulse period by using a chopper wheel with narrow slots separated by wide spokes. Different methods of synchronizing the chopper wheel and pulsing of the light sources are explored. The capability of the chopper wheel system is illustrated with time-resolved measurements of pulsed plasmas

  9. Digital image intensifier radiography: first experiences with the DSI (Digital Spot Imaging)

    International Nuclear Information System (INIS)

    Rueckforth, J.; Wein, B.; Stargardt, A.; Guenther, R.W.

    1995-01-01

    We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digital imaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. With exception of the criterion of edge sharpness, DSI yields a significantly inferior assessment compared with the film/screen technique. (orig./MG) [de

  10. Design overview of the ITER core CXRS fast shutter and manufacturing implications during the detailed design work

    Energy Technology Data Exchange (ETDEWEB)

    Castaño Bardawil, David Antonio, E-mail: d.castano.bardawil@fz-juelich.de [Institute of Energy and Climate Research – Plasma Physics, Forschungszentrum Jülich GmbH (Germany); Mertens, Philippe [Institute of Energy and Climate Research – Plasma Physics, Forschungszentrum Jülich GmbH (Germany); Offermanns, Guido; Behr, Wilfried [Central Institute for Engineering, Electronics and Analytics, Forschungszentrum Jülich GmbH (Germany); Hawkes, Nick [Culham Centre for Fusion Energy (Germany); Krasikov, Yury [Institute of Energy and Climate Research – Plasma Physics, Forschungszentrum Jülich GmbH (Germany); Balboa, Itziar [Culham Centre for Fusion Energy (Germany); Biel, Wolfgang; Samm, Ulrich [Institute of Energy and Climate Research – Plasma Physics, Forschungszentrum Jülich GmbH (Germany)

    2015-10-15

    Highlights: • Keeping key parameters during design has facilitated quick iteration assessment. • Proper pipe bending and welding procedures were established for manufacturing. • Bellows assemblies and manufacturing were adequately defined for the actuator. • Successful cooperation between our in-house workshop and the industry. • Full shutter manufacturing drawings were successfully developed. - Abstract: At first a detailed fast shutter design was finalized for the ITER core charge exchange recombination spectroscopy (CXRS) diagnostic. The shutter has approximately 70 kg of mass and a length of 2.1 m. It operates in fractions of a second (0.7 s) protecting critical optical components against degradation and providing means of calibration for the optical system. The shutter structure is driven by a bidirectional frictionless helium actuator, with forces and axial strokes of 3.4 kN and 2 mm respectively. The shutter structure consists of: (a) two blades made of CuCrZr and stainless steel, calibration surfaces (currently Al{sub 2}O{sub 3}) on the top and on the bottom a protective TZM (Mo–0.5Ti–0.08Zr) screens, (b) two arms interconnected that form one cooling circuit including the blades, (c) a bumper system to limit the arms movement, and (d) a support. A description of these components and their functions are given in this paper, followed by some issues, and their corresponding solutions or ongoing investigations, encountered during the design work. Detailed manufacturing drawings have been developed as the deliverable final product of this design stage, and are used in the prototyping phase which includes testing, numerical benchmarking, and validation of the shutter concept.

  11. Development of an image intensifier-TV digital imaging system with a multiple-slit scanning x-ray beam

    International Nuclear Information System (INIS)

    Kume, Y.; Doi, K.

    1986-01-01

    The authors are developing a new digital x-ray imaging system employing a multiple-slit assembly (MSA) and an image intensifier (II)-TV digital system. The final image consisting of primary radiation is digitally reconstructed from multiple slit images obtained with the MSA. This system can significantly reduce the scattered radiation from an object and the veiling glare from II-TV system. The quality of the reconstructed image is related to many parameters, such as slit width, the number of image frames, and the image reconstruction algorithm. They present the effect of these various parameters on basic imaging properties and the practicability of the method in comparison with conventional wide beam imaging

  12. Comparison of vessel contrast measured with a scanning-beam digital x-ray system and an image intensifier/television system

    International Nuclear Information System (INIS)

    Speidel, Michael A.; Wilfley, Brian P.; Heanue, Joseph A.; Betts, Timothy D.; Van Lysel, Michael S.

    2001-01-01

    Vessel contrast was measured in the fluoroscopic images produced by a scanning-beam digital x-ray (SBDX) system and an image intensifier/television (II/TV) based system. The SBDX system electronically scans a series of pencil x-ray beams across the patient, each of which is directed at a distant small-area detector array. The reduction in detected scatter achieved with this geometry was expected to provide an increase in image contrast. Vessel contrast was evaluated from images of a phantom containing iodinated tubes. The vessels were inserted into an acrylic stack to provide a patient-mimicking scattering medium. Vessel diameter ranged from 0.3 to 3.1 mm. Images were acquired at 100 kVp with the SBDX and II/TV systems and averaged to reduce x-ray noise. The II/TV system was operated in the 6-in. image intensifier mode with an anti-scatter grid. The increase in contrast in the SBDX images, expressed as a ratio of the measured SBDX and II/TV contrasts, ranged from 1.63 to 1.79 for individual vessels. This agreed well with a prediction of the contrast improvement ratio for this experiment, based on measurements of the scatter fraction, object-plane line spread functions, and consideration of the source spectrum and detector absorption properties. The predicted contrast improvement ratio for SBDX relative to II/TV images was 1.62 to 1.77

  13. Value of intensified nursing

    OpenAIRE

    Raymann, Cornelia; Konta, Brigitte; Prusa, Nina; Frank, Wilhelm

    2006-01-01

    The concept "intensified nursing" is mentioned in differentiation to concepts of "nursing care" or "nursing" which intensifies resources or patient contact. Especially psychic and social needs of patients are very appreciated in nursing. A similar type of nursing is known under the concept "advanced nursing practice" (ANP) which means, that a specialised, academically trained nurse offers an extended nursing care in which a focus on the published knowledge of evidence based research is made. ...

  14. Fluoroscopy without image intensifier

    International Nuclear Information System (INIS)

    Canevaro, L.; Drexler, G.

    2001-01-01

    The objective of the present work was to evaluate the doses received by patients during fluoroscopy procedures carried out with an equipment without image intensifier. This evaluation is providing dose levels that our patients are presently exposed, and gives the data for epidemiological studies on risk estimate of cancer induction in patients exposed earlier when no image intensifiers existed. Diamentor M4 and E meters were used to measure the product dose-area (DAP). The data were acquired during barium enema, barium meal, barium swallow and histerosalpingographies. The measured values of DAP are considered high. This work intends to call the attention toward the optimization of the radiological protection in facilities that still use equipment without image intensifiers. While this equipment cannot be disabled, the patient exposure monitoring should be an incentive, and the application of radiological protection practices and programs of quality assurance should be of priority. (author)

  15. Neutron image intensifier tubes

    International Nuclear Information System (INIS)

    Verat, M.; Rougeot, H.; Driard, B.

    1983-01-01

    The most frequently used techniques in neutron radiography employ a neutron converter consisting of either a scintillator or a thin metal sheet. The radiation created by the neutrons exposes a photographic film that is in contact with the converter: in the direct method, the film is exposed during the time that the object is irradiated with neutrons; in the transfer method, the film is exposed after the irradiation of the object with neutrons. In industrial non-destructive testing, when many identical objects have to be checked, these techniques have several disadvantages. Non-destructive testing systems without these disadvantages can be constructed around neutron-image intensifier tubes. A description and the operating characteristics of neutron-image intensifier tubes are given. (Auth.)

  16. Radiographic intensifying screens

    International Nuclear Information System (INIS)

    Van Landeghem, W.K.; Suys, A.R.

    1979-01-01

    A fluorescent x-ray image intensifying screen is described which comprises discrete particles of fluorescent material dispersed in a binder layer. Intensifying screens are employed to increase the exposure of a photosensitive plate or film without increasing the x-ray exposure dose when struck by x-rays. The screen has an outermost layer containing solid particulate material protruding from a coherent film-forming organic binder medium and having a static friction coefficient at room temperature not higher than 0.50 on steel. The outermost layer may be characterized by micro-unevennesses of at least 3 μm and at least 9 protruding particles per 0.35 sq. cm. These particles have a static friction coefficient less than 0.3 and are made of a solid polystyrene, polyaklylene and/or a solid organic fluorinated polymer. (JTA)

  17. Photon attenuation by intensifying screens

    International Nuclear Information System (INIS)

    Holje, G.

    1983-01-01

    The photon attenuation by intensifying screens of different chemical composition has been determined. The attenuation of photons between 20 keV and 120 keV was measured by use of a multi-channel analyzer and a broad bremsstrahlung distribution. The attenuation by the intensifying screens was hereby determined simultaneously at many different monoenergetic photon energies. Experimentally determined attenuations were found to agree well with attenuation calculated from mass attenuation coefficients. The attenuation by the screens was also determined at various bremsstrahlung distributions, simulating those occurring behind the patient in various diagnostic X-ray examinations. The high attenuation in some of the intensifying screens form the basis for an analysis of the construction of asymmetric screen pairs. Single screen systems are suggested as a favourable alternative to thick screen pair systems. (Author)

  18. Diagnostics of plasma jet instabilities using fast shutter imaging

    Czech Academy of Sciences Publication Activity Database

    Chumak, Oleksiy; Hrabovský, Milan

    2006-01-01

    Roč. 56, suppl.B (2006), B767-B773 ISSN 0011-4626. [Symposium on Plasma Physics and Technology /22nd./. Praha, 26.6.2006-29.6.2006] R&D Projects: GA ČR GA202/05/0669 Institutional research plan: CEZ:AV0Z20430508 Keywords : plasma jet * jet instabilities * plasma fluctuation * visualization Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.568, year: 2006

  19. Intensifying screens in transaxial tomography

    International Nuclear Information System (INIS)

    Debelder, M.H.; Bollen, R.H.

    1981-01-01

    This patent claim by Agfa-Gevaert relates to a method for the production of transaxial tomographs, a combination of materials therefor and X-ray intensifying screens incorporating at least one reflecting element for use in transaxial tomography, wherein the exposure of a photographic silver halide emulsion material proceeds at an angle within the range of 2 0 to 10 0 in conjunction with an X-ray fluorescent intensifying screen including an ultra-violet and/or visible radiation reflective coating or sheet to increase the radiation output of the screen and to reduce the exposure time and radiation dose e.g. in medical X-ray applications. (author)

  20. X-ray intensifying screens

    International Nuclear Information System (INIS)

    Bossomaier, T.R.J.; Sangway, P.C.

    1979-01-01

    It is claimed that stabilization of X-ray intensifying screens against discolouration and hydrolysis of lanthanum or gadolinium oxyhalide phosphors can be achieved by incorporating into the phosphor/binder formulation a compound containing free epoxy groups. Suitable epoxy compounds include gamma glycidoxy trimethoxy silane and dimethyl di(m-glycidoxy methylphenyl) methane. The oxyhalide may be activated by Tb, Tm or Yb and may be mixed with other phosphors. Plasticisers and organo-tin stabilisers for the formulation are given. Many binders are specified, preferably these should not react with the free epoxy groups. (UK)

  1. Multiple event 2D image intensifier scintillation detector

    International Nuclear Information System (INIS)

    Thieberger, P.; Wegner, H.E.; Lee, R.C.

    1981-01-01

    An image intensifier scintillation detector has been developed for the simultaneous detection of multiple light or heavy ions down to very low energies. The relative X-Y positions of each ion are read out by digitization of a television image of the light amplified scintillations. The maximum data rate is limited by the present television scan speed to 15 multiple events per second and to about one event second by the microcomputer presently used to store and process the data. (orig.)

  2. X-ray intensifying screens

    International Nuclear Information System (INIS)

    Luckey, G.W.; DeBoer, C.D.

    1982-01-01

    An x-ray intensifying screen comprises a support which has a luminescent composition comprising an isotropic phosphor and a polymer having an index of refraction within 0.02 of that of the phosphor over at least 80 percent of its emission spectrum. The support has an index of refraction up to or equal to 0.05 units higher than that of the phosphor and has a reflection optical density of at least 1.7 to light emitted by the phosphor. A preferred luminescent composition comprises Kl:Tl, Rbl:Tl at BaSrFCl:Eu mixed with two monomers such as 1-naphthylmethylmethacrylate, S(1-naphthylmethyl) thioacrylate, 1-bromo-2-naphthylacrylate, and benzyl methacrylate, coated on black anodised Al and polymerised in situ. The ratio of monomers is adjusted to give the desired refractive index. Other phosphors, polymers and supports are specified together with the preparation of the monomers and polymers. (author)

  3. Operating radiographic image intensifier tube

    International Nuclear Information System (INIS)

    Marche, E.; Girard, A.; Barjot, D.; Deon, J.M.; Lacoste, Y.

    1996-01-01

    The intensifier tube operation method involves a voltage supply (U) which is placed across two transistors (Q 1, Q 2) in series. The voltage driver to the photocathode (PC) is the centre point between the two transistors. A switching command is applied to a logic circuit (CL). The logic circuit drives two light emitting diodes (DEL1, DEL2) when a threshold light level is exceeded, each LED triggers an optical switch (TR1, TR2). The switches change the state of the transistors. Switching the upper transistor on and the lower transistor off applies a voltage to the photocathode. Switching off the upper transistor and on the lower transistor blocks the high voltage and sets the photocathode to zero. The advantage of this device is that it involves circuit regulator which is less complex, it has cheaper and more easily implemented transient protection and has reduced sizes. (authors). 10 figs

  4. Recent progress in color image intensifier

    International Nuclear Information System (INIS)

    Nittoh, K.

    2010-01-01

    A multi-color scintillator based high-sensitive, wide dynamic range and long-life X-ray image intensifier (Ultimage TM ) has been developed. Europium activated Y 2 O 2 S scintillator, emitting red, green and blue wavelength photons of different intensities, is utilized as the output fluorescent screen of the intensifier. By combining this image intensifier with a suitably tuned high sensitive color CCD camera, the sensitivity of the red color component achieved six times higher than that of the conventional image intensifier. Simultaneous emission of a moderate green color and a weak blue color covers different sensitivity regions. This widens the dynamic range by nearly two orders of magnitude. With this image intensifier, it is possible to image complex objects containing various different X-ray transmissions from paper, water or plastic to heavy metals at a time. This color scintillator based image intensifier is widely used in X-ray inspections of various fields. (author)

  5. Digitization

    DEFF Research Database (Denmark)

    Finnemann, Niels Ole

    2014-01-01

    what a concept of digital media might add to the understanding of processes of mediatization and what the concept of mediatization might add to the understanding of digital media. It is argued that digital media open an array of new trajectories in human communication, trajectories which were...

  6. Lexicon and Description of Sui Adjective Intensifiers

    Directory of Open Access Journals (Sweden)

    James N. Stanford

    2007-01-01

    Full Text Available Sui, an indigenous minority language of southwest China, has an elaborate system of adjective intensification. Adjectives are intensified with word-specific, bound morphemes that usually either rhyme with the base or alliterate with the base. Stanford (2007 notes morpho-phonological patterns that suggest reduplication, rhyme, alliteration, The Emergence of the Unmarked (McCarthy & Prince 1994, Yip 2001, identity avoidance, and “Copy But Don’t Repeat” (Kennard 2004. However, the adjective intensifiers defy a simple, fully predictable explanation in such terms; the intensifier lexicon may be best described as “patterned variety,” a case of lexicalized poetry or a poeticized lexicon. Word formation is guided by general patterns, but each specific intensifier may vary within those overall guidelines. Many adjectives have multiple intensifiers that bear subtle semantic and pragmatic distinctions. The current paper serves as a complement to Stanford (2007 by providing a detailed lexicon of the Sui adjective intensifiers for future reference and further analysis. This lexicon is based on the author’s fieldwork and represents the first detailed account of Sui adjective intensifiers for the wider linguistic community.

  7. X-ray image intensifier photography

    International Nuclear Information System (INIS)

    Richter, K.; Angerstein, W.; Steinhardt, L.

    1980-01-01

    The present treatise on X-ray image intensifier photography starts with introductory remarks on the history of X-ray imaging and image intensifiers. In the physical-technological part especially the quality of image and the methods of its measurement are discussed in detail. The relevant equipment such as image intensifier cameras, X-ray television, video recorder and devices of display and evaluation of images are presented as well as problems of radiation doses and radiation protection. Based on 25,000 examinations of the digestive, the biliary and the urinary tract, resp., as well as of the blood vessels the applicability of the X-ray image intensifier photography and its diagnostic value are demonstrated in the medical part of the book

  8. Characteristics of image converters and image intensifiers

    International Nuclear Information System (INIS)

    Gurvich, A.M.; Shamanov, A.A.; Rozenberg, A.M.; Fajnberg, V.S.; Kavtorova, V.P.; Salyuk, L.V.; Yakovleva, F.B.

    1978-01-01

    The characteristics of image converters and image intensifiers, which determine the range of the X-radiation dose rates used and the image quality, are considered. The equations for calculating the requirements to be imposed on the separate intensifier elements from known parameters of other elements with an allowance for the nonlinearity of the television system and the role of fluctuation in the space distribution of X-radiation quanta are given

  9. X-ray image intensifier tube

    International Nuclear Information System (INIS)

    1981-01-01

    An improved real-time x-ray image intensifier tube of the proximity type used for medical x-ray fluoroscopy is described. It is claimed that this intensifier is of sufficient gain and resolution whilst remaining convenient to use and that the design is such that the patient dosage is minimized whilst the x-ray image information content at the scintillator-photocathode screen is maximized. (U.K.)

  10. Characterization study of an intensified complementary metal-oxide-semiconductor active pixel sensor

    Science.gov (United States)

    Griffiths, J. A.; Chen, D.; Turchetta, R.; Royle, G. J.

    2011-03-01

    An intensified CMOS active pixel sensor (APS) has been constructed for operation in low-light-level applications: a high-gain, fast-light decay image intensifier has been coupled via a fiber optic stud to a prototype "VANILLA" APS, developed by the UK based MI3 consortium. The sensor is capable of high frame rates and sparse readout. This paper presents a study of the performance parameters of the intensified VANILLA APS system over a range of image intensifier gain levels when uniformly illuminated with 520 nm green light. Mean-variance analysis shows the APS saturating around 3050 Digital Units (DU), with the maximum variance increasing with increasing image intensifier gain. The system's quantum efficiency varies in an exponential manner from 260 at an intensifier gain of 7.45 × 103 to 1.6 at a gain of 3.93 × 101. The usable dynamic range of the system is 60 dB for intensifier gains below 1.8 × 103, dropping to around 40 dB at high gains. The conclusion is that the system shows suitability for the desired application.

  11. DIGITAL

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — The Digital Flood Insurance Rate Map (DFIRM) Database depicts flood risk information and supporting data used to develop the risk data. The primary risk...

  12. Assessment of uniformity and signal-to-noise ratio in radiological image intensifier TV systems

    International Nuclear Information System (INIS)

    Malone, J.F.; O'Connor, M.K.; Maher, K.P.

    1985-01-01

    A method of measuring the uniformity of radiological Image Intensifier-TV systems is described. Large non-uniformities were observed in the systems tested. A method of estimating the Signal-to-Noise Ratio in such systems is also presented and applied to characterise the effectiveness of the noise reduction techniques used in digital fluoroscopy. (author)

  13. Colour-the-INSight : Combining a direct view rifle sight with fused intensified and thermal imagery

    NARCIS (Netherlands)

    Hogervorst, M.A.; Jansen, C.; Toet, A.; Bijl, P.; Bakker, P.J.; Hiddema, A.C.; Vliet, S.F. van

    2012-01-01

    We present the design and evaluation of a new demonstrator rifle sight viewing system containing direct view, red aim point and fusion of an (uncooled, LWIR) thermal sensor with a digital image intensifier. Our goal is to create a system that performs well under a wide variety of (weather)

  14. Development of a 3-dimensional CT using an image intensifier

    International Nuclear Information System (INIS)

    Toyofuku, Fukai

    1992-01-01

    A prototype of three-dimensional CT (Fluoroscopic CT) has been developed using an image intensifier as a two-dimensional X-ray detector. A patient on a rotating table is projected onto an image intensifier by a cone beam of X-ray from the X-ray tube. A total of 390 projection images covering 180 degrees are acquired in a single scan (13 sec) and stored on a digital frame recorder (512 x 256 x 8-bit x 480). The transverse axial images are reconstructed by using the usual CT reconstruction algorithm, while longitudinal section images such as sagittal, coronal, oblique, and panoramic images are obtained by directly back-projecting the filtered projection image onto the sections. The radiation exposure was measured with an ionization chamber, and the exposure of the present fluoroscopic CT is about 10 to 20 times less than that of conventional X-ray CT. A similar monochromatic X-ray CT system has also been developed using synchrotron radiation. Large area parallel X-rays are obtained from a wiggler beam using a silicon crystal with [311] asymmetric reflection. By taking two images above and below iodine K-absorption edge (33.17 keV), iodine image is obtained. (author)

  15. C.C.D. readout of a picosecond streak camera with an intensified C.C.D

    International Nuclear Information System (INIS)

    Lemonier, M.; Richard, J.C.; Cavailler, C.; Mens, A.; Raze, G.

    1984-08-01

    This paper deals with a digital streak camera readout device. The device consists in a low light level television camera made of a solid state C.C.D. array coupled to an image intensifier associated to a video-digitizer coupled to a micro-computer system. The streak camera images are picked-up as a video signal, digitized and stored. This system allows the fast recording and the automatic processing of the data provided by the streak tube

  16. A self triggered intensified Ccd (Stic)

    International Nuclear Information System (INIS)

    Charon, Y.; Laniece, P.; Bendali, M.

    1990-01-01

    We are developing a new device based on the results reported previously of the successfull coincidence detection of β- particles with a high spatial resolution [1]. The novelty of the device consists in triggering an intensified CCD, i.e. a CCD coupled to an image intensifier (II), by an electrical signal collected from the II itself. This is a suitable procedure for detecting with high efficiency and high resolution low light rare events. The trigger pulse is obtained from the secondary electrons produced by multiplication in a double microchannel plate (MCP) and collected on the aluminized layer protecting the phosphor screen in the II. Triggering efficiencies up to 80% has been already achieved

  17. Human water consumption intensifies hydrological drought worldwide

    International Nuclear Information System (INIS)

    Wada, Yoshihide; Van Beek, Ludovicus P H; Wanders, Niko; Bierkens, Marc F P

    2013-01-01

    Over the past 50 years, human water use has more than doubled and affected streamflow over various regions of the world. However, it remains unclear to what degree human water consumption intensifies hydrological drought (the occurrence of anomalously low streamflow). Here, we quantify over the period 1960–2010 the impact of human water consumption on the intensity and frequency of hydrological drought worldwide. The results show that human water consumption substantially reduced local and downstream streamflow over Europe, North America and Asia, and subsequently intensified the magnitude of hydrological droughts by 10–500%, occurring during nation- and continent-wide drought events. Also, human water consumption alone increased global drought frequency by 27 (±6)%. The intensification of drought frequency is most severe over Asia (35 ± 7%), but also substantial over North America (25 ± 6%) and Europe (20 ± 5%). Importantly, the severe drought conditions are driven primarily by human water consumption over many parts of these regions. Irrigation is responsible for the intensification of hydrological droughts over the western and central US, southern Europe and Asia, whereas the impact of industrial and households’ consumption on the intensification is considerably larger over the eastern US and western and central Europe. Our findings reveal that human water consumption is one of the more important mechanisms intensifying hydrological drought, and is likely to remain as a major factor affecting drought intensity and frequency in the coming decades. (letter)

  18. Digital multilayer tomography

    International Nuclear Information System (INIS)

    Dueber, C.; Klose, K.J.; Thelen, M.

    1991-01-01

    With digital multilayer tomography a sequence of projection images is recorded by an image intensifier television system and stored as digital data during a linear run of a layer sequence. Using this data record, tomograms of the examined body region can be computed for any layer thickness by shifts and superimposition of the single projections later at a digital workstation. The qualities of digital and conventional tomograms are basically comparable. A drawback of digital tomography is its lower local resolution (512 x 512 image matrix), advantages are a lower radiation exposure, a shorter patient examination time, and the facilities of digital image processing (later processing, archive setup, transmission). (orig.) [de

  19. Experience with digital mammography

    Directory of Open Access Journals (Sweden)

    G. P. Korzhenkova

    2011-01-01

    Full Text Available The use of digital techniques in mammography has become a last step for completing the process of digitization in diagnostic imaging. It is assumed that such a spatial decision will be required for digital mammography, as well as for high-resolution intensifying screen-film systems used in conventional mammography and that the digital techniques will be limited by the digitizer pixel size on detecting minor structures, such as microcalcifications. The introduction of digital technologies in mammography involves a tight control over an image and assures its high quality.

  20. Intensified coastal development behind nourished beaches

    Science.gov (United States)

    Armstrong, Scott; Lazarus, Eli; Limber, Patrick; Goldstein, Evan; Thorpe, Curtis; Ballinger, Rhoda

    2016-04-01

    Population density, housing development, and property values in coastal counties along the U.S. Atlantic and Gulf Coasts continue to rise despite increasing hazard from storm impacts. Since the 1970s, beach nourishment, which involves importing sand to deliberately widen an eroding beach, has been the main strategy in the U.S. for protecting coastal properties from erosion and flooding hazards. Paradoxically, investment in hazard protection may intensify development. Here, we examine the housing stock of all existing shorefront single-family homes in Florida - a microcosm of U.S. coastal hazards and development - to quantitatively compare development in nourishing and non-nourishing towns. We find that nourishing towns now account for more than half of Florida's coastline, and that houses in nourishing towns are larger and more numerous. Even as the mean size of single-family homes nationwide has grown steadily since 1970, Florida's shorefront stock has exceeded the national average by 34%, and in nourishing towns by 45%. This emergent disparity between nourishing and non-nourishing towns in Florida demonstrates a pattern of intensifying coastal risk, and is likely representative of a dominant trend in coastal development more generally. These data lend empirical support to the hypothesis that US coastal development and hazard mitigation through beach nourishment have become dynamically coupled.

  1. Digital vascular imaging

    International Nuclear Information System (INIS)

    Ludwig, J.W.; Engels, B.C.H.

    1981-01-01

    Digitalizing videosignals from an image intensifying TV-chain, followed by subtraction, contrast intensifying, and reformation to analogous signal deliver angiography pictures of high quality after intravenous injection of the contrast medium. As the examination is only little invasive it can be carried out on outdoor patients or in the polyclinics. The possibilities of the digital vessel imagination (DVI) are shown at vessel images of different parts of the body; a 36 cm image intensifyer which can be switched to 3 different sorts of operation and has a plumbicon-TV recording tube is used as receiver. (orig.) [de

  2. Upwards Intensifiers in the English, German and Croatian Language

    Directory of Open Access Journals (Sweden)

    Anita Pavić Pintarić

    2014-12-01

    Full Text Available This paper investigates the upwards intensifiers (adverbs of intensifying in the English, German and Croatian language. Intensity as an important human cognitive category, and language expressivity is differently treated in grammars and dictionaries of all three languages, especially with respect to different degrees of intensity. In this paper we argue that it is possible to model a typology of upwards adverb intensifiers in the three languages, according to their morphosyntactic and semantic aspects. When it comes to intensifiers, it is necessary to describe which collocates are modified by intensifiers and which semantic fields the collocates belong to. The results of the corpus analysis based on Harry Potter novels show that all the three languages express the category of the upwards intensity in the same way: the number of intensifiers is similar, the collocates mostly belong to the same semantic fields and word classes, they have similar syntactic functions.

  3. Digital radiography

    International Nuclear Information System (INIS)

    Rath, M.; Lissner, J.; Rienmueller, R.; Haendle, J.; Siemens A.G., Erlangen

    1984-01-01

    Using a prototype of an electronic, universal examination unit equipped with a special X-ray TV installation, spotfilm exposures and digital angiographies with high spatial resolution and wide-range contrast could be made in the clinic for the first time. With transvenous contrast medium injection, the clinical results of digital angiography show excellent image quality in the region of the carotids and renal arteries as well as the arteries of the extremities. The electronic series exposures have an image quality almost comparable to the quality obtained with cutfilm changers in conventional angiography. There are certain limitations due to the input field of 25 cm X-ray image intensified used. In respect of the digital angiography imaging technique, the electronic universal unit is fully suitable for clinical application. (orig.) [de

  4. Duodenal fat intensifies the perception of heartburn

    Science.gov (United States)

    Meyer, J; Lembo, A; Elashoff, J; Fass, R; Mayer, E

    2001-01-01

    BACKGROUND—Patients with gastro-oesophageal reflux disease (GORD) frequently report that meals high in fat worsen heartburn. Nevertheless, studies to determine whether high fat meals promote gastro-oesophageal reflux have produced conflicting and equivocal conclusions.
PATIENTS AND METHODS—To determine, alternatively, whether fat in the small intestinal lumen intensifies the perception of heartburn, we studied 11 patients with typical heartburn from GORD. After being placed on omeprazole to suppress endogenous acid, these fasting subjects underwent oesophageal perfusions with graded doses of HCl at pH values of 1.0, 1.5, 2.0, and 2.5. Oesophageal perfusions were conducted while the duodenum was perfused with saline (control) and again with fat at 8 g/h.
RESULTS—Time to onset, intensity, and severity of heartburn varied with dose of oesophageal acid (pheartburn significantly (pheartburn.


Keywords: gastro-oesophageal reflux disease; heartburn; perception; fat PMID:11600463

  5. 12-inch x-ray image intensifier with thin metal input window

    Energy Technology Data Exchange (ETDEWEB)

    Obata, Yoshiharu; Anno, Hidero; Harao, Norio [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    1982-08-01

    Borosilicate glass has been used for X-ray input window of image intensifiers (I.I.) up to now. Now two new types of 12-inch metal I.I., RT12301C and RT12302C, have been developed. They use convex 1-mm aluminum (instead of 5-mm borosilicate glass) for the input window. Adopting a high-performance penta-electronic lens and a new type of light guide CsI film, these intensifiers have greatly improved contrast, quantum detection efficiency (QDE) and resolution capability. In spite of low dosage, image quality equivalent to that in the conventional direct radiograph is obtained through combined use of the new-type 12-inch metal I.I. with 0.3-mm small-focal-spot X-ray tube. Great contribution to digital radiography is expected of this I.I.

  6. Image quality in digital radiography

    International Nuclear Information System (INIS)

    Kuhn, H.

    1986-01-01

    The contribution deals with the potentials of digital radiography and critically evaluates the advantages of drawbacks of the image intensifier-tv-digital system; digitalisation of the X-ray film and scanning of luminescent storage foils. The evaluation is done in comparison with the image quality of the traditional, large-size X-ray picture. (orig.) [de

  7. New feature of the neutron color image intensifier

    Science.gov (United States)

    Nittoh, Koichi; Konagai, Chikara; Noji, Takashi; Miyabe, Keisuke

    2009-06-01

    We developed prototype neutron color image intensifiers with high-sensitivity, wide dynamic range and long-life characteristics. In the prototype intensifier (Gd-Type 1), a terbium-activated Gd 2O 2S is used as the input-screen phosphor. In the upgraded model (Gd-Type 2), Gd 2O 3 and CsI:Na are vacuum deposited to form the phosphor layer, which improved the sensitivity and the spatial uniformity. A europium-activated Y 2O 2S multi-color scintillator, emitting red, green and blue photons with different intensities, is utilized as the output screen of the intensifier. By combining this image intensifier with a suitably tuned high-sensitive color CCD camera, higher sensitivity and wider dynamic range could be simultaneously attained than that of the conventional P20-phosphor-type image intensifier. The results of experiments at the JRR-3M neutron radiography irradiation port (flux: 1.5×10 8 n/cm 2/s) showed that these neutron color image intensifiers can clearly image dynamic phenomena with a 30 frame/s video picture. It is expected that the color image intensifier will be used as a new two-dimensional neutron sensor in new application fields.

  8. New feature of the neutron color image intensifier

    International Nuclear Information System (INIS)

    Nittoh, Koichi; Konagai, Chikara; Noji, Takashi; Miyabe, Keisuke

    2009-01-01

    We developed prototype neutron color image intensifiers with high-sensitivity, wide dynamic range and long-life characteristics. In the prototype intensifier (Gd-Type 1), a terbium-activated Gd 2 O 2 S is used as the input-screen phosphor. In the upgraded model (Gd-Type 2), Gd 2 O 3 and CsI:Na are vacuum deposited to form the phosphor layer, which improved the sensitivity and the spatial uniformity. A europium-activated Y 2 O 2 S multi-color scintillator, emitting red, green and blue photons with different intensities, is utilized as the output screen of the intensifier. By combining this image intensifier with a suitably tuned high-sensitive color CCD camera, higher sensitivity and wider dynamic range could be simultaneously attained than that of the conventional P20-phosphor-type image intensifier. The results of experiments at the JRR-3M neutron radiography irradiation port (flux: 1.5x10 8 n/cm 2 /s) showed that these neutron color image intensifiers can clearly image dynamic phenomena with a 30 frame/s video picture. It is expected that the color image intensifier will be used as a new two-dimensional neutron sensor in new application fields.

  9. New method of digital angiography

    International Nuclear Information System (INIS)

    Hashiya, Junichi; Korenaga, Takeo; Sakurai, Kenji; Sakai, Fumikazu; Kato, Hisatoyo; Takano, Masao.

    1982-01-01

    New experience of digital angiography using Fuji Intelligent Diagnostic X-ray System was reported. The system utilizes newly developed high sensitivity imaging plate in conjunction with computerized image processor instead of image intensifier-TV series, thus drastically improving image quality. Initial clinical trial was made in 46 cases including intravenous digital subtraction angiography and transcatheter digital arteriography. The advantages of this method were summerized as: 1. better resolution, 2. wider field size, 3. more sophisticated image manipulation program. (author)

  10. Fluorescent intensifying screens: contribution of secondary X-rays

    International Nuclear Information System (INIS)

    Barroso, R.C.; Goncalves, O.D.; Eichler, J.; Lopes, R.T.; Cardoso, S.C.

    1996-01-01

    The counting rate and angular distribution of secondary X-rays produced by fluorescent intensifying screens are studied. A source of 241 Am - gamma radiation of 59.54 keV - is used. Fluorescent intensifying screens reduce the radiation dose in radiology since they produce visible light which increases the efficiency of the film. In addition, secondary X-rays arise due to the photoelectric effect, elastic (Rayleigh) and inelastic (Compton) scattering

  11. Pengaruh Jenis Lembar Penguat (Intensifying Screen) Terhadap Densitas Radiografi

    OpenAIRE

    Nasrullah

    2007-01-01

    good ABSTRACT As done research on the influence of type to the density radiography with the objective to define radiography value third-density intensifying screen brand green emitting variation factors exposure and Focus Film Distance is different. Influence of type of intensifying screen to the density radiography is obtained through measurements of the value of radiography density using the densitometer with object stepwedge. The results of this research show that the average dens...

  12. A taxonomy of control in intensified processes

    International Nuclear Information System (INIS)

    Barzin, R.; Abd Shukor, S.R.; Ahmad, A.L.

    2006-01-01

    Process Intensification (PI) is a revolutionary approach to design, development and implementation of process and plant. PI technology offers improved environment in a chemical process in terms of better products, and processes which are safer, cleaner, smaller - and cheaper. PI is a strategy of making dramatic reductions in the size of unit operations within chemical plants, in order to achieve given production objectives. However, PI technology would be handicapped if such system is not properly controlled. There are some foreseeable problems in order to control such processes for instance, dynamic interaction between components that make up a control loop, response time of the instrumentations, availability of proper sensor and etc. In some cases, in order to control these systems, advanced control solutions have been applied i.e. model predictive controllers (MPC) and its different algorithms such as quadratic generalized predictive control (QGPC) and self tuning quadratic generalized predictive control (STQGPC). Nevertheless in some cases simpler solutions could be applied to control such system for example proportional integral controller in the control of reactive distillation systems. As mentioned, conventional control systems like proportional-integral, proportional-integral-derivative (PID) controllers and their different structures can be used in PI systems but due to inherent nonlinearity and fast responsiveness of PI systems, digital controllers-regarding to their robustness-are mostly applied in order to control PI systems. Regarding to the fact that choosing the appropriate control strategy is the most essential part of making PI systems possible to be handle easily, taxonomy of the usage of various control structure in controlling PI systems is proposed. This paper offers an overview and discussion on identifying potential problems of instrumentation in PI technology and available control strategies

  13. Digital cardiovascular imaging

    International Nuclear Information System (INIS)

    Myerowitz, P.D.; Mistretta, C.A.; Shaw, C.-G.; Van Lysel, M.S.; Swanson, D.K.; Lasser, T.A.; Dhanani, S.P.; Zarnstorff, W.C.; Vander Ark, C.R.; Dobbins, J.T.; Peppler, W.W.; Crummy, A.B.

    1982-01-01

    The authors have previously reported on real time digital fluoroscopic subtraction techniques developed in the laboratory during the past 10 years. This paper outlines basic apparatus configuration and imaging modes used for preliminary studies involving visualization of the canine and human heart. All of the techniques involve the use of real time digital subtraction processing of data from an image intensified television fluoroscopy system. Based on the configuration of the digital processing equipment a number of different imaging modalities are possible. A brief description of the apparatus and these imaging modes is given. (Auth.)

  14. Characterization of a team biplane digital x-ray in the pediatric cardiology department; Caracterizacion de un equipo biplano de rayos x digital en el servicio de cardiologia pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Ordonez Marquez, J.; Huertas Martinez, C.; Corredora Silva, E.; Vano Carruana, E.; Luquero LLopis, N.; Huerga Cabrerizo, C.; Plaza Aparicio, R.; Tellez-Cepeda Ruiz, M.

    2011-07-01

    In cardiology, new digital technologies, are replacing fluoroscopy with image intensifier and television systems. There has been a characterization of the equipment prior to commissioning for clinical use.

  15. Panel type X-ray image intensifier tube

    International Nuclear Information System (INIS)

    Wang, S.P.

    1977-01-01

    A panel shaped, proximity type, X-ray image intensifier tube for medical X-ray diagnostic is disclosed. It has all linear components and yet a high brightness gain, in the range of 500 to 20,000 cd-sec/m 2 -R, the tube being comprised of a rugged metallic tube envelope, an inwardly concave metallic input window of full size output display screen, an alkaline-halide scintillator photocathode screen suspended on insulators within the envelope and in between the input window and the output screen, and a high Z glass output window to reduce X-ray backscatter inside and outside of the tube. An X-ray sensitive photographic camera for medical diagnostic use is also disclosed which includes an X-ray sensitive image intensifier means of the proximity type and a reduction type optical system having an effective foral length in excess of 100mm for focusing the emage generated on the output display screen of the image intensifier tube onto a small size but directly viewable photographic film. The parameters of the image intensifier, the optics and the film are specified and linked to each other in a manner which maximizes the image quality for a camera system of this type and at the same time restricts the system speed of the camera to a range of 500 to 5,000 R -1 for the film to achieve a net density of 1.0. (Auth.)

  16. Dysphagia screening and intensified oral hygiene reduce pneumonia after stroke

    DEFF Research Database (Denmark)

    Sørensen, Rikke Terp; Rasmussen, Rune Skovgaard; Overgaard, Karsten

    2013-01-01

    Dysphagia occurs in approximately 51%-78% of patients with acute stroke. The incidence of pneumonia caused by aspiration in dysphagic patients increases both mortality and the need for hospitalization. The aim of this study was to investigate whether the incidence of aspiration pneumonia could...... be reduced in such patients by an early screening for dysphagia and intensified oral hygiene....

  17. The image intensifier in oral and maxillofacial surgery

    International Nuclear Information System (INIS)

    Gans, B.J.; Kallal, R.H.; Helgerson, A.C.; Verona, S.R.

    1982-01-01

    The mobile image intensifier has been found useful in the removal of foreign bodies from both intraoral and extraoral sites. The safety of the machine has been verified, and a technique for its application is described. Additional uses for the machine are stated

  18. Intensified multifactorial intervention and cardiovascular outcome in type 2 diabetes

    DEFF Research Database (Denmark)

    Pedersen, Oluf; Gaede, Peter

    2003-01-01

    We recently published the results of the Steno-2 study, which evaluated the benefits of intensified integrated behavior modification and targeted polypharmacy. The results provide abundant evidence that an ambitious treatment strategy is superior to a conventional one. The study involved 160 high...

  19. Emulsification in novel ultrasonic cavitation intensifying bag reactors

    NARCIS (Netherlands)

    Zwieten, van Ralph; Verhaagen, Bram; Schroën, Karin; Fernández Rivas, David

    2017-01-01

    Cavitation Intensifying Bags (CIBs), a novel reactor type for use with ultrasound, have been recently proposed as a scaled-up microreactor with increased energy efficiencies. We now report on the use of the CIBs for the preparation of emulsions out of hexadecane and an SDS aqueous solution. The

  20. Using Brief Experimental Analysis to Intensify Tier 3 Reading Interventions

    Science.gov (United States)

    Coolong-Chaffin, Melissa; Wagner, Dana

    2015-01-01

    As implementation of multi-tiered systems of support becomes common practice across the nation, practitioners continue to need strategies for intensifying interventions and supports for the subset of students who fail to make adequate progress despite strong programs at Tiers 1 and 2. Experts recommend making several changes to the structure and…

  1. Dynamics analysis of extraction of manganese intensified by electric field

    Science.gov (United States)

    Ma, Wenrui; Tao, Changyuan; Li, Huizhan; Liu, Zuohua; Liu, Renlong

    2018-06-01

    In this study, a process reinforcement technology for leaching process of pyrolusite was developed. The electric field was introduced to decrease reaction temperature and improve the leaching rate of pyrolusite. The mechanisms of electric field intensifying leaching process of pyrolusite were investigated through X-ray diffraction (XRD), and Brunauer Emmett Teller (BET) in detail. The results showed that the electric field could decrease obviously the apparent activation energy of leaching process of pyrolusite. The apparent activation energy of the leaching of pyrolusite intensified by electric field was calculated to be 53.76 kJ.mol-1. In addition, the leaching efficiency of manganese was effectively increased by 10% to 20% than that without electric field under the same conditions. This was because that the electron conduit between Fe (II)/Fe (III) and pyrite was dredged effectively by electric field.

  2. Digital radiology. Clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Stacul, F; Smathers, R L

    1985-01-01

    The authors report the experience achieved ad the Stanford University (USA) with a digital radiography system which allows the digitization of the film and of the images collected with photostimulable phophors. The phophor is essentially an intensifying screen where a latent image is stored after exposure to X-rays and is extracted by a laser scanning. The images collected with the digitized film and with the phophor (chest, breast, bone) have been analyzed. The digitized film offers potential diagnostic advantages over the conventional film, because of the contrast manipulation and many other processing options. The possibility to recover the information of overexposed films appears very attractive. The photostimulable phophors allow to get good quality images, with a consistent reduction of dose and costs. These plates offer the possibility, in the next future, to replace the conventional screen-film systems.

  3. Digital subtraction angiography

    International Nuclear Information System (INIS)

    Neuwirth, J. Jr.; Bohutova, J.

    1987-01-01

    The quality of radiodiagnostic methods to a great extent depends on the quality of the resulting image. The basic technical principles are summed up of the different parts of digital subtraction angiography apparatus and of methods of improving the image. The instrument is based on a videochain consisting of an X-ray tube, an intensifier of the radiographic image, optical parts, a video camera, an analog-to-digital converter and a computer. The main advantage of the digitally processed image is the possibility of optimizing the image into a form which will contain the biggest amount of diagnostically valuable information. Described are the mathematical operations for improving the digital image: spatial filtration, pixel shift, time filtration, image integration, time interval differentation and matched filtering. (M.D.). 8 refs., 3 figs

  4. The role of heat pipes in intensified unit operations

    International Nuclear Information System (INIS)

    Reay, David; Harvey, Adam

    2013-01-01

    Heat pipes are heat transfer devices that rely, most commonly, on the evaporation and condensation of a working fluid contained within them, with passive pumping of the condensate back to the evaporator. They are sometimes referred to as ‘thermal superconductors’ because of their exceptionally high effective thermal conductivity (substantially higher than any metal). This, together with several other characteristics make them attractive to a range of intensified unit operations, particularly reactors. The majority of modern computers deploy heat pipes for cooling of the CPU. The application areas of heat pipes come within a number of broad groups, each of which describes a property of the heat pipe. The ones particularly relevant to chemical reactors are: i. Separation of heat source and sink. ii. Temperature flattening, or isothermalisation. iii. Temperature control. Chemical reactors, as a heat pipe application area, highlight the benefits of the heat pipe based on isothermalisation/temperature flattening device and on being a highly effective heat transfer unit. Temperature control, done passively, is also of relevance. Heat pipe technology offers a number of potential benefits to reactor performance and operation. The aim of increased yield of high purity, high added value chemicals means less waste and higher profitability. Other intensified unit operations, such as those employing sorption processes, can also profit from heat pipe technology. This paper describes several variants of heat pipe and the opportunities for their use in intensified plant, and will give some current examples. -- Highlights: ► Heat pipes – thermal superconductors – can lead to improved chemical reactor performance. ► Isothermalisation within a reactor vessel is an ideal application. ► The variable conductance heat pipe can control reaction temperatures within close limits. ► Heat pipes can be beneficial in intensified reactors

  5. Achieving interlocking nails without using an image intensifier.

    Science.gov (United States)

    Ikem, Innocent C; Ogunlusi, Johnson D; Ine, Henry R

    2007-08-01

    Interlocking nails are commonly performed using an image intensifier. These are expensive and are not readily available in most resource-poor countries of the world. The aim of this study was to achieve interlocking nailing without the use of an image intensifier. This is a prospective descriptive analysis of 40 consecutive cases seen with shaft fractures of the humerus, femur, and tibia. Fracture fixation was done using Surgical Implant Generation Network (SIGN) nails. Forty limbs in 34 patients were studied. There were 12 females and 22 males, giving a ratio of 1:2. The mean age (years) was 35.75+/-13.16 and the range was 17-70 years. The studied bones were: humerus 10%, femur 65%, and tibia 25%. The fracture lines were: transverse 40%, oblique 15%, and communited 45%. Fracture grades were: closed 90%, grade I, 5%, grade II, 2.5%, and grade IIIA, 2.5%. Surgical approaches were: antegrade 62.5% and retrograde 37.5%. Indications for fixation were: recent fracture 92.5%, non-union 5%, and malunion 3%. Methods of reductions were: open 85% and closed 15%. The mean follow-up period (years) was 1.50+/-0.78. The union time averaged 3 months. Complication was mainly screw loosening due to severe osteoporoses in one case. It is, therefore, concluded that, with the aid of external jigs and slot finders, interlocking can be achieved without an image intensifier.

  6. Dynamic flat panel detector versus image intensifier in cardiac imaging: dose and image quality

    Science.gov (United States)

    Vano, E.; Geiger, B.; Schreiner, A.; Back, C.; Beissel, J.

    2005-12-01

    The practical aspects of the dosimetric and imaging performance of a digital x-ray system for cardiology procedures were evaluated. The system was configured with an image intensifier (II) and later upgraded to a dynamic flat panel detector (FD). Entrance surface air kerma (ESAK) to phantoms of 16, 20, 24 and 28 cm of polymethyl methacrylate (PMMA) and the image quality of a test object were measured. Images were evaluated directly on the monitor and with numerical methods (noise and signal-to-noise ratio). Information contained in the DICOM header for dosimetry audit purposes was also tested. ESAK values per frame (or kerma rate) for the most commonly used cine and fluoroscopy modes for different PMMA thicknesses and for field sizes of 17 and 23 cm for II, and 20 and 25 cm for FD, produced similar results in the evaluated system with both technologies, ranging between 19 and 589 µGy/frame (cine) and 5 and 95 mGy min-1 (fluoroscopy). Image quality for these dose settings was better for the FD version. The 'study dosimetric report' is comprehensive, and its numerical content is sufficiently accurate. There is potential in the future to set those systems with dynamic FD to lower doses than are possible in the current II versions, especially for digital cine runs, or to benefit from improved image quality.

  7. Improved fluorescent X-ray image intensifying screen

    International Nuclear Information System (INIS)

    Landeghem, W.K. van; Suys, A.R.

    1981-01-01

    An X-ray image intensifying screen is described, which includes at least one fluorescent layer comprising phosphor particles dispersed in a binder and on top of such layer a protective layer containing a crosslinked polymer mass obtained by an acid-catalyzed reaction of a polymer or mixture of polymers containing reactive hydrogen atoms and a cross-linking agent, the cross-linking agent being an organic compound containing a plurality of etherified N-methylol groups. Examples are given of appropriate polymers and cross-linking agents. (author)

  8. Integrated Process Design, Control and Analysis of Intensified Chemical Processes

    DEFF Research Database (Denmark)

    Mansouri, Seyed Soheil

    chemical processes; for example, intensified processes such as reactive distillation. Most importantly, it identifies and eliminates potentially promising design alternatives that may have controllability problems later. To date, a number of methodologies have been proposed and applied on various problems......, that the same principles that apply to a binary non-reactive compound system are valid also for a binary-element or a multi-element system. Therefore, it is advantageous to employ the element based method for multicomponent reaction-separation systems. It is shown that the same design-control principles...

  9. Study of secondary X-rays from radiographic intensifying screens

    International Nuclear Information System (INIS)

    Barroso, R.C.; Eichler, J.; Lopes, R.T.; Cardoso, S.C.

    1998-01-01

    To reduce the radiation dose in radiology, fluorescent intensifying screens for X-ray films are used. They produce visible light which increases the efficiency of the film. In addition, there are two other effects that will degrade the image resolution. First, the gadolinium present in the screens produces X-rays isotropically. Second, the primary radiation can be scattered elastically (Rayleigh scattering) and inelastically (Compton scattering). The intensity and angular distribution of these secondary radiation were measured, showing that the ratio of secondary-to-primary radiation incident on the X-ray film is about 16%. (orig.)

  10. Selection of Rational Heat Transfer Intensifiers in the Heat Exchanger

    Directory of Open Access Journals (Sweden)

    S. A. Burtsev

    2016-01-01

    Full Text Available The paper considers the applicability of different types of heat transfer intensifiers in the heat exchange equipment. A review of the experimental and numerical works devoted to the intensification of the dimpled surface, surfaces with pins and internally ribbed surface were presented and data on the thermal-hydraulic characteristics of these surfaces were given. We obtained variation of thermal-hydraulic efficiency criteria for 4 different objective functions and 15 options for the intensification of heat transfer. This makes it possible to evaluate the advantages of the various heat transfer intensifiers. These equations show influence of thermal and hydraulic characteristics of the heat transfer intensifiers (the values of the relative heat transfer and drag coefficients on the basic parameters of the shell-and-tube heat exchanger: the number and length of the tubes, the volume of the heat exchanger matrix, the coolant velocity in the heat exchanger matrix, coolant flow rate, power to pump coolant (or pressure drop, the amount of heat transferred, as well as the average logarithmic temperature difference. The paper gives an example to compare two promising heat transfer intensifiers in the tubes and shows that choosing the required efficiency criterion to search for optimal heat exchanger geometry is of importance. Analysis is performed to show that a dimpled surface will improve the effectiveness of the heat exchanger despite the relatively small value of the heat transfer intensification, while a significant increase in drag of other heat transfer enhancers negatively affects their thermalhydraulic efficiency. For example, when comparing the target functions of reducing the heat exchanger volume, the data suggest that application of dimpled surfaces in various fields of technology is possible. But there are also certain surfaces that can reduce the parameters of a heat exchanger. It is shown that further work development should be aimed at

  11. A distortion correction method for image intensifier and electronic portal images used in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Ioannidis, G T; Geramani, K N; Zamboglou, N [Strahlenklinik, Stadtische Kliniken Offenbach, Offenbach (Germany); Uzunoglu, N [Department of Electrical and Computer Engineering, National Technical University of Athens, Athens (Greece)

    1999-12-31

    At the most of radiation departments a simulator and an `on line` verification system of the treated volume, in form of an electronic portal imaging device (EPID), are available. Networking and digital handling (saving, archiving etc.) of the image information is a necessity in the image processing procedures in order to evaluate verification and simulation recordings at the computer screen. Distortion is on the other hand prerequisite for quantitative comparison of both image modalities. Another limitation factor, in order to make quantitative assertions, is the fact that the irradiation fields in radiotherapy are usually bigger than the field of view of an image intensifier. Several segments of the irradiation field must therefore be acquired. Using pattern recognition techniques these segments can be composed into a single image. In this paper a distortion correction method will be presented. The method is based upon a well defined Grid which is embedded during the registration process on the image. The video signal from the image intensifier is acquired and processed. The grid is then recognised using image processing techniques. Ideally if all grid points are recognised, various methods can be applied in order to correct the distortion. But in practice this is not the case. Overlapping structures (bones etc.) have as a consequence that not all of the grid points can be recognised. Mathematical models from the Graph theory are applied in order to reconstruct the whole grid. The deviation of the grid points positions from the rated value is then used to calculate correction coefficients. This method (well defined grid, grid recognition, correction factors) can also be applied in verification images from the EPID or in other image modalities, and therefore a quantitative comparison in radiation treatment is possible. The distortion correction method and the application on simulator images will be presented. (authors)

  12. Measurement of the uniformity of X-ray image-intensifier television systems and of the system components

    International Nuclear Information System (INIS)

    Cooney, P.; Maher, K.P.; Malone, J.F.

    1989-01-01

    Uniformity is a well defined term used to describe the response of a gamma camera to a ''uniform'' radiation input. A similar quantity is required in the specification of the image-intensifier (II) television (TV) chains used in fluoroscopic imaging, particularly in vascular, cardiac and digital applications. This paper presents work on the use of the National Electrical Manufacturers' Association definition of uniformity for gamma cameras and its refinement for application in the field with II-TV chains as whole systems. The methods of measurement employed using on-site high-quality videotape recording combined with an off-site and off-line digital image processor are described. The impact of noise reduction and matrix size on the results in outlined. The contribution of individual components of the chain to the non-uniformity have also been assessed in detail using methods of measurement and definitions specifically developed to be suitable for application in the hospital environment by an experienced physicist. The methods and results for (i) the X-ray beam, (ii) the image intensifier and (iii) the TV system are presented. These methods have been tested by applying them to a sample of 10 II-TV systems in routine hospital use and the results are reported. (author)

  13. Quality control of image-intensifier television chains in Finland

    International Nuclear Information System (INIS)

    Pirinen, M.

    1989-01-01

    There are some 500 image-intensifier television (TV) chains connected to fluoroscopic units in Finland, most installed in the 1970s, although the oldest still in use date back to the late 1960s. To establish performance levels of the chains, 300 of them were assessed in 1982 by the Finnish Centre for Radiation and Nuclear Safety (STUK). Results showed great diversity in the condition of the chains. The main reason was lack of periodical quality assurance of the chains. Recommendations for limits were established from results of assessing three parameters describing the condition of the chains: spatial resolution, automatically controlled dose-rate and contrast sensitivity. Recommendations also advise hospitals on how to arrange alternative quality assurance measurements and observations, either by hospital's maintenance staff, the manufacturer, or the supervising authority (STUK). Results following adoption of the recommendations by hospitals are presented. (author)

  14. Marfan syndrome gene search intensifies following identification of basic defect

    Energy Technology Data Exchange (ETDEWEB)

    Randall, T.

    1990-10-03

    Somewhere, quite possible along chromosomes 8 and/or 15, the gene(s) for Marfan syndrome will be found. The search is intensifying following a report that faulty scaffolding in the body's connective tissue appears to be the long sought after defect behind the syndrome, and inherited disorder that has caused the premature death of young, healthy-looking individuals. Finding that something in the living masonry of the human body has proven to be a 30-year inquisition of nearly two dozen molecules that has engaged investigators worldwide. Historically, researchers have searched for a structural flaw in one of the collagen molecules to explain the cause of Marfan Syndrome. Using monoclonal antibodies, researchers have implicated microfibrils, the extracellular filaments that provide a matrix for the deposit of elastin during embryonic development.

  15. Sustainable and Intensified Design of a Biodiesel Production Process

    DEFF Research Database (Denmark)

    Mansouri, Seyed Soheil; Ismail, Muhammad I.; Babi, Deenesh Kavi

    impact and maximum profitability is needed. In this work a computer-aided framework for process synthesis and process intensification is applied for sustainable production of biodiesel from pure/waste palm oil as the feedstock. This approach examines several biodiesel processing routes that were...... collected through available data and current technologies reported in the literature. Using this information, a generic superstructure of processing routes was created that described a network of configurations representing multiple designs for the production of biodiesel. Therefore, based on the currently...... of economic and environmental sustainability was identified. For the case of biodiesel production, the intensified process alternative turned out to be the most economical and more sustainable than other alternatives. The computer-aided methods and tools used in this work are: SustainPro (method and tool...

  16. Dynamic behavior of the intensified alternative configurations for quaternary distillation

    DEFF Research Database (Denmark)

    Ramirez-Marquez, Cesar; Cabrera-Ruiz, Julián; Juan Gabriel Segovia-Hernandez, Juan Gabriel

    2016-01-01

    Process intensification emerges as an important tool in the synthesis of multicomponent distillation configurations aimed at the reduction of the energy use and capital costs. Operational and fixed costs savings coupled with simplicity and controllability design configurations appear as an essent......Process intensification emerges as an important tool in the synthesis of multicomponent distillation configurations aimed at the reduction of the energy use and capital costs. Operational and fixed costs savings coupled with simplicity and controllability design configurations appear...... value decomposition technique in all frequency domain. In order to complete the control study, the distillation schemes were subjected to closed-loop dynamic simulations. The results show that there are cases in which the intensified sequences do not only provide energy savings, but also may offer...

  17. System Design and Performance Test of Hydraulic Intensifier

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Eui; Lee, Gi Chun [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of); Kim, Jae Hoon [Chungnam National University, Daejeon (Korea, Republic of)

    2010-07-15

    Components such as pressure vessel, hydraulic hose assembly, accumulator, hydraulic cylinder, hydraulic valve, pipe, etc., are tested under the impulse-pressure conditions prescribed in ISO and SAE standards. The impulse pressure test machine needs to have a high pressure, a precise control system and a long life. It should satisfy the requirements for fabrication of the impulse tester to generate ultra high pressure in the hydraulic system. In the impulse tester, a servo-valve control system is adopted; although the control application is convenient, it is expensive owing to the cost of developing the system. The type of the control system determines the pressure wave, which affects the components that are tested. In this study, the manufacturing process and the intensifier system design related to the flow, pressure, and the increasing rate of pressure are investigated. The results indicate the ultra high pressure waves in the system.

  18. New intensifying screens in clinical radiology. Pt. 2

    International Nuclear Information System (INIS)

    Freyschmidt, J.; Saure, D.; Hagemann, G.

    1976-01-01

    A clinically applicable procedure for testing new intensifying rare earth screens, as well as the special Siemens' screen is described. The results are related to universal screeens. The film-screen combination α 4XD (gadolinium oxysulphide with normal, green sensitive film) results in a reduction of radiation dose to half with detail comparable with universal screens. The Siemens' special screen has similar advantages. Screens with a higher intensification factor and reduction of the mAs to one sixth results in loss of detail. This does not necessarily reduce their clinical use if they are used for appropriate purposes. The results of this clinically orientated technique agreed well with physically objective methods using lead grids. The advantages of the new screens are discussed in terms of their practical application. (orig.) [de

  19. Fluoroscopic digital radiography

    International Nuclear Information System (INIS)

    Hynes, D.M.; Rowlands, J.A.; Edmonds, E.W.; Porter, A.J.; Toth, B.D.

    1987-01-01

    The authors have been working with three different developmental systems, exploring the clinical benefits of digital recording of the fluoroscopic image. This educational exhibit describes the components of such systems and emphasizes the strengths and weaknesses of each. Specific technical reference is made to the image intensifier, TV camera, 1,024/sup 2/ image store, hard copy devices, and the mechanics of operation in the general fluoroscopic environment. All observations indicate that the problems of resolution, motion blur, noise, field size, and dose can be solved. The findings are supported by clinical examples

  20. Digital subtraction angiography in patients with central vertigo

    International Nuclear Information System (INIS)

    Inamori, Toru; Takayasu, Yukio; Umetani, Yoshio; Taruoka, Akinori.

    1985-01-01

    Digital subtraction angiography (DSA) is a recently developed non-invasive intravenous angiography which has become possible through real time digital subtraction of x-ray transmission data from an image intensifier and television system. The output signals of the image intensifier-television camera system are digitized by an analog-digital converter. The digital information, 512x512 pixels and 9 bits deep, is fed into the image processing assembly after logarithmic amplification, where 2-8 frames are added and subtracted from mask images for the final digital images. Intravenous digital subtraction angiography was performed in 21 patients with intractable dizzy spells of central origin resistant to treatment. These patients showed some signs of CNS disturbance, although there were no significant findings on CT scans. Surprisingly, findings were abnormal in 14 of 21 patients (66.7%). DSA is, therefore, considered to be an important aid in the diagnosis of vertigo of the central type. (J.P.N.)

  1. Digital subtraction angiography system evaluation with phantoms

    International Nuclear Information System (INIS)

    Wenstrup, R.S.; Sweeney, K.P.; Scholz, F.J.

    1985-01-01

    Advances in digital subtraction angiography imaging demonstrate the need for critical evaluation of the performance of digital subtraction equipment. The design of a phantom set for noninvasive assessment of the imaging quality of digital subtraction equipment is described; components include a remotely controlled transport system and individual patterns to evaluate the contrast and detail properties of the image intensifier, low-contrast sensitivity and resolution of the system, geometric distortion of image, linearity, mechanical and electronic stability of equipment, and effects of bone and bowel gas on iodine perception. The performance of an add-on digital radiographic system is presented, along with radiation exposure levels at the image intensifier for a range of radiographic techniques

  2. Axial Tomography from Digitized Real Time Radiography

    Science.gov (United States)

    Zolnay, A. S.; McDonald, W. M.; Doupont, P. A.; McKinney, R. L.; Lee, M. M.

    1985-01-18

    Axial tomography from digitized real time radiographs provides a useful tool for industrial radiography and tomography. The components of this system are: x-ray source, image intensifier, video camera, video line extractor and digitizer, data storage and reconstruction computers. With this system it is possible to view a two dimensional x-ray image in real time at each angle of rotation and select the tomography plane of interest by choosing which video line to digitize. The digitization of a video line requires less than a second making data acquisition relatively short. Further improvements on this system are planned and initial results are reported.

  3. Digital broadcasting

    International Nuclear Information System (INIS)

    Park, Ji Hyeong

    1999-06-01

    This book contains twelve chapters, which deals with digitization of broadcast signal such as digital open, digitization of video signal and sound signal digitization of broadcasting equipment like DTPP and digital VTR, digitization of equipment to transmit such as digital STL, digital FPU and digital SNG, digitization of transmit about digital TV transmit and radio transmit, digital broadcasting system on necessity and advantage, digital broadcasting system abroad and Korea, digital broadcasting of outline, advantage of digital TV, ripple effect of digital broadcasting and consideration of digital broadcasting, ground wave digital broadcasting of DVB-T in Europe DTV in U.S.A and ISDB-T in Japan, HDTV broadcasting, satellite broadcasting, digital TV broadcasting in Korea, digital radio broadcasting and new broadcasting service.

  4. Madagascar's future climate change intensified actions and policy ...

    African Journals Online (AJOL)

    or business as usual? Jean-Roger MercierI ... reduce its 2030 emissions by 64% compared to the 'Business As ..... tion of work in the global, climate-conscious digital economy. ... business models for the development and delivery of physical goods and services. The potential for deploying ICTs for innovative products ...

  5. Impacts of Intensified Agriculture Developments on Marsh Wetlands

    Directory of Open Access Journals (Sweden)

    Zhaoqing Luan

    2013-01-01

    Full Text Available A spatiotemporal analysis on the changes in the marsh landscape in the Honghe National Nature Reserve, a Ramsar reserve, and the surrounding farms in the core area of the Sanjiang Plain during the past 30 years was conducted by integrating field survey work with remote sensing techniques. The results indicated that intensified agricultural development had transformed a unique natural marsh landscape into an agricultural landscape during the past 30 years. Ninety percent of the natural marsh wetlands have been lost, and the areas of the other natural landscapes have decreased very rapidly. Most dry farmland had been replaced by paddy fields during the progressive change of the natural landscape to a farm landscape. Attempts of current Chinese institutions in preserving natural wetlands have achieved limited success. Few marsh wetlands have remained healthy, even after the establishment of the nature reserve. Their ecological qualities have been declining in response to the increasing threats to the remaining wetland habitats. Irrigation projects play a key role in such threats. Therefore, the sustainability of the natural wetland ecosystems is being threatened by increased regional agricultural development which reduced the number of wetland ecotypes and damaged the ecological quality.

  6. Direct view panel type X-ray image intensifier tube

    International Nuclear Information System (INIS)

    Yang, S.-P.; Robbins, C.D.; Merrit, E.

    1977-01-01

    A panel shaped, proximity type, X-ray image intensifier tube for medical X-ray fluoroscopy use is described. It has all linear components and yet a high brightness gain, in excess of 4,000 cd-sec/m 2 -R, the tube being comprised of a rugged metallic tube envelope, an inwardly concave metallic input window, a directly viewable full size output display screen, and a scintillator-photocathode screen having a thickness of at least 200 microns for a high X-ray photon utilization ability as well as X-ray stopping power, the scintillator-photocathode screen being suspended on insulators within the envelope and in between the input window and the output screen. The scintillator-photocathode screen is spaced from the output screen by at least 8mm to allow the application of a high negative potential at the scintillator-photocathode screen with respect to the output screen for high gain with low field emission, since all of the remaining components within the tube envelope are at neutral potential with respect to the output display screen. (Auth.)

  7. Social exclusion intensifies anxiety-like behavior in adolescent rats.

    Science.gov (United States)

    Lee, Hyunchan; Noh, Jihyun

    2015-05-01

    Social connection reduces the physiological reactivity to stressors, while social exclusion causes emotional distress. Stressful experiences in rats result in the facilitation of aversive memory and induction of anxiety. To determine the effect of social interaction, such as social connection, social exclusion and equality or inequality, on emotional change in adolescent distressed rats, the emotional alteration induced by restraint stress in individual rats following exposure to various social interaction circumstances was examined. Rats were assigned to one of the following groups: all freely moving rats, all rats restrained, rats restrained in the presence of freely moving rats and freely moving rats with a restrained rat. No significant difference in fear-memory and sucrose consumption between all groups was found. Change in body weight significantly increased in freely moving rats with a restrained rat, suggesting that those rats seems to share the stressful experience of the restrained rat. Interestingly, examination of the anxiety-like behavior revealed only rats restrained in the presence of freely moving rats to have a significant increase, suggesting that emotional distress intensifies in positions of social exclusion. These results demonstrate that unequally excluded social interaction circumstances could cause the amplification of distressed status and anxiety-related emotional alteration. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Elite synchronized swimmers display decreased energy availability during intensified training.

    Science.gov (United States)

    Schaal, K; Tiollier, E; Le Meur, Y; Casazza, G; Hausswirth, C

    2017-09-01

    Elite synchronized swimmers follow high-volume training regimen that result in elevated rates of exercise energy expenditure (ExEE). While adequate energy intake (EI) is important to optimize recovery, a number of sport-specific constraints may lead to chronically low energy availability (EA = EI-ExEE). This study aimed to quantify changes in EA, endocrine markers of energy conservation, and perceived fatigue in synchronized swimmers, during a week of baseline training followed by 4 weeks of intensified training (IT). EI, ExEE, and body composition were measured in nine swimmers at Baseline, midpoint (IT WK 2 ), and end of IT (IT WK 4 ). Waking saliva samples were obtained to measure [leptin] s , [ghrelin] s , and [cortisol] s . Fatigue ratings were provided daily. ExEE increased by 27% during IT. Swimmers increased EI from Baseline to IT WK 2 , but decreased it significantly from IT WK 2 to IT WK 4 . EA, fat mass, and [leptin] s decreased from Baseline to IT WK 4 , while [ghrelin] s increased significantly. Fatigue at IT WK 4 was inversely correlated with Baseline EI and EA. The significant decrease in EA was accompanied by endocrine signs of energy conservation in elite swimmers. As perceived fatigue was associated with low EA, particular attention should be paid to these athletes' energy intake during phases of heavy training. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Tide-surge Interaction Intensified by the Taiwan Strait

    Science.gov (United States)

    Zhang, Wen-Zhou; Shi, Fengyan; Hong, Hua-Sheng; Shang, Shao-Ping; Kirby, James T.

    2010-06-01

    The Taiwan Strait is a long and wide shelf-channel where the hydrodynamics is extremely complex, being characterized by strong tides, and where storm surges frequently occur during the typhoon season. Obvious oscillations due to tide-surge interaction were observed by tide gauges along the northern Fujian coast, the west bank of the Taiwan Strait, during Typhoon Dan (1999). Numerical experiments indicate that nonlinear bottom friction (described by the quadratic formula) is a major factor to predict these oscillations while the nonlinear advective terms and the shallow water effect have little contribution. It is found that the tide-surge interaction in the northern portion of the Taiwan Strait is intensified by the strait. Simulations based on simplified topographies with and without the island of Taiwan show that, in the presence of the island, the channel effect strengthens tidal currents and tends to align the major axes of tidal ellipses along the channel direction. Storm-induced currents are also strengthened by the channel. The pattern of strong tidal currents and storm-induced currents along the channel direction enhances tide-surge interaction via the nonlinear bottom friction, resulting in the obvious oscillations along the northern Fujian coast.

  10. 40° image intensifier tubes in an integrated helmet system

    Science.gov (United States)

    Schreyer, Herbert; Boehm, Hans-Dieter V.; Svedevall, B.

    1993-12-01

    EUROCOPTER has been under contract to the French and German ministries of defence for five years to develop the TIGER, a second generation anti-tank helicopter. A piloting thermal imager has been installed on a steerable platform in the helicopter nose in order to achieve the possibility of flying round the clock. In addition to this sensor, which is sensitive at a wavelength of 10 micrometers , the German side has proposed using an Integrated Helmet System in the PAH 2. This helmet, manufactured by GEC-Marconi Avionics, incorporates two cathode ray tubes (CRT) and two image intensifier tubes which allow the pilot to use an additional sensor in the visible and near infrared spectrum. The electronic part will be built by Teldix. EUROCOPTER DEUTSCHLAND has received the first demonstrator of this helmet for testing in the EUROCOPTER Visionics Laboratory. Later, the C-prototype will be integrated into a BK 117 helicopter (AVT Avionik Versuchstrager). This new helmet has a field of view of 40 degree(s), and exit pupil of 15 mm and improved possibilities of adjusting the optical part. Laboratory tests have been carried out to test important parameters like optical resolution under low light level conditions, field of view, eye relief or exit pupil. The CRT channels have been tested for resolution, distortion, vignetting and homogeneity. The requirements and the properties of the helmet, test procedures and the results of these tests are presented in the paper.

  11. X-ray image intensifier camera tubes and semiconductor targets

    International Nuclear Information System (INIS)

    1979-01-01

    A semiconductor target for use in an image intensifier camera tube and a camera using the target are described. The semiconductor wafer for converting an electron image onto electrical signal consists mainly of a collector region, preferably n-type silicon. It has one side for receiving the electron image and an opposite side for storing charge carriers generated in the collector region by high energy electrons forming a charge image. The first side comprises a highly doped surface layer covered with a metal buffer layer permeable to the incident electrons and thick enough to dissipate some of the incident electron energy thereby improving the signal-to-noise ratio. This layer comprises beryllium on niobium on the highly doped silicon surface zone. Low energy Kα X-ray radiation is generated in the first layer, the radiation generated in the second layer (mainly Lα radiation) is strongly absorbed in the silicon layer. A camera tube using such a target with a photocathode for converting an X-ray image into an electron image, means to project this image onto the first side of the semiconductor wafer and means to read out the charge pattern on the second side are also described. (U.K.)

  12. Measurement of the uniformity of X-ray image-intensifier television systems and of the system components

    International Nuclear Information System (INIS)

    Cooney, P.; Maher, K.P.; Malone, J.F.

    1989-01-01

    This paper presents work on the use of the National Electrical Manufacturers' Association definition of uniformity for gamma cameras and its refinement for application in the field with image intensified television (II-TV) chains as whole systems. Methods of measurement employed using on-site high-quality videotape recording combined with an off-site and off-line digital image processor are described. Impact of noise reduction and matrix size on the results is outlined. The contribution of individual components of the chain to the non-uniformity have also been assessed in detail using methods of measurement and definitions specifically developed to be suitable for application in the hospital environment by an experienced physicist. The methods and results for (i) the X-ray beam, (ii) the image intensifier and (iii) the TV system are presented. These methods have been tested by applying them to a sample of 10 II-TV systems in routine hospital use and results are reported. (author)

  13. 21 CFR 892.1650 - Image-intensified fluoroscopic x-ray system.

    Science.gov (United States)

    2010-04-01

    ... fluoroscopic x-ray system. (a) Identification. An image-intensified fluoroscopic x-ray system is a device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Image-intensified fluoroscopic x-ray system. 892... equipment, patient and equipment supports, component parts, and accessories. (b) Classification. Class II...

  14. 21 CFR 892.1660 - Non-image-intensified fluoroscopic x-ray system.

    Science.gov (United States)

    2010-04-01

    ... fluoroscopic x-ray system. (a) Identification. A non-image-intensified fluoroscopic x-ray system is a device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Non-image-intensified fluoroscopic x-ray system... display equipment, patient and equipment supports, component parts, and accessories. (b) Classification...

  15. Two micron pore size MCP-based image intensifiers

    Science.gov (United States)

    Glesener, John; Estrera, Joseph

    2010-02-01

    Image intensifiers (I2) have many advantages as detectors. They offer single photon sensitivity in an imaging format, they're light in weight and analog I2 systems can operate for hours on a single AA battery. Their light output is such as to exploit the peak in color sensitivity of the human eye. Until recent developments in CMOS sensors, they also were one of the highest resolution sensors available. The closest all solid state solution, the Texas Instruments Impactron chip, comes in a 1 megapixel format. Depending on the level of integration, an Impactron based system can consume 20 to 40 watts in a system configuration. In further investing in I2 technology, L-3 EOS determined that increasing I2 resolution merited a high priority. Increased I2 resolution offers the system user two desirable options: 1) increased detection and identification ranges while maintaining field-of-view (FOV) or 2) increasing FOV while maintaining the original system resolution. One of the areas where an investment in resolution is being made is in the microchannel plate (MCP). Incorporation of a 2 micron MCP into an image tube has the potential of increasing the system resolution of currently fielded systems. Both inverting and non-inverting configurations are being evaluated. Inverting tubes are being characterized in night vision goggle (NVG) and sights. The non-inverting 2 micron tube is being characterized for high resolution I2CMOS camera applications. Preliminary measurements show an increase in the MTF over a standard 5 micron pore size, 6 micron pitch plate. Current results will be presented.

  16. Restraint stress intensifies interstitial K+ accumulation during severe hypoxia

    Directory of Open Access Journals (Sweden)

    Christian eSchnell

    2012-03-01

    Full Text Available Chronic stress affects neuronal networks by inducing dendritic retraction, modifying neuronal excitability and plasticity, and modulating glial cells. To elucidate the functional consequences of chronic stress for the hippocampal network, we submitted adult rats to daily restraint stress for three weeks (6 h/day. In acute hippocampal tissue slices of stressed rats, basal synaptic function and short-term plasticity at Schaffer collateral/CA1 neuron synapses were unchanged while long-term potentiation was markedly impaired. The spatiotemporal propagation pattern of hypoxia-induced spreading depression episodes was indistinguishable among control and stress slices. However, the duration of the extracellular direct current (DC potential shift was shortened after stress. Moreover, K+ fluxes early during hypoxia were more intense, and the postsynaptic recoveries of interstitial K+ levels and synaptic function were slower. Morphometric analysis of immunohistochemically stained sections suggested hippocampal shrinkage in stressed rats, and the number of cells that are immunoreactive for GFAP (glial fibrillary acidic protein was increased in the CA1 subfield indicating activation of astrocytes. Western blots showed a marked downregulation of the inwardly rectifying K+ channel Kir4.1 in stressed rats. Yet, resting membrane potentials, input resistance and K+-induced inward currents in CA1 astrocytes were indistinguishable from controls. These data indicate an intensified interstitial K+ accumulation during hypoxia in the hippocampus of chronically stressed rats which seems to arise from a reduced interstitial volume fraction rather than impaired glial K+ buffering. One may speculate that chronic stress aggravates hypoxia-induced pathophysiological processes in the hippocampal network and that this has implications for the ischemic brain.

  17. Predator cannibalism can intensify negative impacts on heterospecific prey.

    Science.gov (United States)

    Takatsu, Kunio; Kishida, Osamu

    2015-07-01

    Although natural populations consist of individuals with different traits, and the degree of phenotypic variation varies among populations, the impact of phenotypic variation on ecological interactions has received little attention, because traditional approaches to community ecology assume homogeneity of individuals within a population. Stage structure, which is a common way of generating size and developmental variation within predator populations, can drive cannibalistic interactions, which can affect the strength of predatory effects on the predator's heterospecific prey. Studies have shown that predator cannibalism weakens predatory effects on heterospecific prey by reducing the size of the predator population and by inducing less feeding activity of noncannibal predators. We predict, however, that predator cannibalism, by promoting rapid growth of the cannibals, can also intensify predation pressure on heterospecific prey, because large predators have large resource requirements and may utilize a wider variety of prey species. To test this hypothesis, we conducted an experiment in which we created carnivorous salamander (Hynobius retardatus) populations with different stage structures by manipulating the salamander's hatch timing (i.e., populations with large or small variation in the timing of hatching), and explored the resultant impacts on the abundance, behavior, morphology, and life history of the salamander's large heterospecific prey, Rana pirica frog tadpoles. Cannibalism was rare in salamander populations having small hatch-timing variation, but was frequent in those having large hatch-timing variation. Thus, giant salamander cannibals occurred only in the latter. We clearly showed that salamander giants exerted strong predation pressure on frog tadpoles, which induced large behavioral and morphological defenses in the tadpoles and caused them to metamorphose late at large size. Hence, predator cannibalism arising from large variation in the timing

  18. Noise analysis of a digital radiography system

    International Nuclear Information System (INIS)

    Arnold, B.A.; Scheibe, P.O.

    1984-01-01

    The sources of noise in a digital video subtraction angiography system were identified and analyzed. Signal-to-noise ratios of digital radiography systems were measured using the digital image data recorded in the computer. The major sources of noise include quantum noise, TV camera electronic noise, quantization noise from the analog-to-digital converter, time jitter, structure noise in the image intensifier, and video recorder electronic noise. A new noise source was identified, which results from the interplay of fixed pattern noise and the lack of image registration. This type of noise may result from image-intensifier structure noise in combination with TV camera time jitter or recorder time jitter. A similar noise source is generated from the interplay of patient absorption inhomogeneities and patient motion or image re-registration. Signal-to-noise ratios were measured for a variety of experimental conditions using subtracted digital images. Image-intensifier structure noise was shown to be a dominant noise source in unsubtracted images at medium to high radiation exposure levels. A total-system signal-to-noise ratio (SNR) of 750:1 was measured for an input exposure of 1 mR/frame at the image intensifier input. The effect of scattered radiation on subtracted image SNR was found to be greater than previously reported. The detail SNR was found to vary approximately as one plus the scatter degradation factor. Quantization error noise with 8-bit image processors (signal-to-noise ratio of 890:1) was shown to be of increased importance after recent improvements in TV cameras. The results of the analysis are useful both in the design of future digital radiography systems and the selection of optimum clinical techniques

  19. Neutron diffraction tomography: a unique, 3D inspection technique for crystals using an intensifier TV system

    International Nuclear Information System (INIS)

    Davidson, J.B.; Case, A.L.

    1978-01-01

    The application of phosphor-intensifier-TV techniques to neutron topography and tomography of crystals is described. The older, analogous x-ray topography using wavelengths approximately 1.5A is widely used for surface inspection. However, the crystal must actually be cut in order to see diffraction anomalies beneath the surface. Because 1.5-A thermal neutrons are highly penetrating, much larger and thicker specimens can be used. Also, since neutrons have magnetic moments, they are diffracted by magnetic structures within crystals. In neutron volume topography, the entire crystal or a large part of it is irradiated, and the images obtained are superimposed reflections from the total volume. In neutron tomography (or section topography), a collimated beam irradiates a slice (0.5 to 10 mm) of the crystal. The diffracted image is a tomogram from this part only. A series of tomograms covering the crystal can be taken as the specimen is translated in steps across the narrow beam. Grains, voids, twinning, and other defects from regions down to 1 mm in size can be observed and isolated. Although at present poorer in resolution than the original neutron and film methods, the TV techniques are much faster and, in some cases, permit real-time viewing. Two camera systems are described: a counting camera having a 150 mm 6 Li-ZnS screen for low-intensity reflections which are integrated in a digital memory, and a 300-mm system using analog image storage. Topographs and tomograms of several crystals ranging in size from 4 mm to 80 mm are shown

  20. [Influence of human body target's spectral characteristics on visual range of low light level image intensifiers].

    Science.gov (United States)

    Zhang, Jun-Ju; Yang, Wen-Bin; Xu, Hui; Liu, Lei; Tao, Yuan-Yaun

    2013-11-01

    To study the effect of different human target's spectral reflective characteristic on low light level (LLL) image intensifier's distance, based on the spectral characteristics of the night-sky radiation and the spectral reflective coefficients of common clothes, we established a equation of human body target's spectral reflective distribution, and analyzed the spectral reflective characteristics of different human targets wearing the clothes of different color and different material, and from the actual detection equation of LLL image intensifier distance, discussed the detection capability of LLL image intensifier for different human target. The study shows that the effect of different human target's spectral reflective characteristic on LLL image intensifier distance is mainly reflected in the average reflectivity rho(-) and the initial contrast of the target and the background C0. Reflective coefficient and spectral reflection intensity of cotton clothes are higher than polyester clothes, and detection capability of LLL image intensifier is stronger for the human target wearing cotton clothes. Experimental results show that the LLL image intensifiers have longer visual ranges for targets who wear cotton clothes than targets who wear same color but polyester clothes, and have longer visual ranges for targets who wear light-colored clothes than targets who wear dark-colored clothes. And in the full moon illumination conditions, LLL image intensifiers are more sensitive to the clothes' material.

  1. Development of multi-color scintillator based X-ray image intensifier

    International Nuclear Information System (INIS)

    Nittoh, Koichi; Konagai, Chikara; Noji, Takashi

    2004-01-01

    A multi-color scintillator based high-sensitive, wide dynamic range and long-life X-ray image intensifier has been developed. An europium activated Y 2 O 2 S scintillator, emitting red, green and blue photons of different intensities, is utilized as the output fluorescent screen of the intensifier. By combining this image intensifier with a suitably tuned high sensitive color CCD camera, it is possible for a sensitivity of the red color component to become six times higher than that of the conventional image intensifier. Simultaneous emission of a moderate green color and a weak blue color covers different sensitivity regions. This widens the dynamic range, by nearly two orders of ten. With this image intensifier, it is possible to image simultaneously complex objects containing various different X-ray transmission from paper, water or plastic to heavy metals. This high sensitivity intensifier, operated at lower X-ray exposure, causes less degradation of scintillator materials and less colorization of output screen glass, and thus helps achieve a longer lifetime. This color scintillator based image intensifier is being introduced for X-ray inspection in various fields

  2. Digital angiography in pulmonary embolism

    International Nuclear Information System (INIS)

    Bjoerk, L.

    1986-01-01

    Pulmonary digital subtraction angiography was diagnostic in 98.3% of patients with possible acute pulmonary embolism. The procedure was well tolerated even in severely ill patients. A large image intensifier made simultaneous imaging of both lungs possible reducing the number of contrast injections necessary. Small volumes of low iso-osmolar concentration of modern contrast media were used. There was no need for catherization of the pulmonary artery. Theoretical considerations and our limited experience indicate that this will reduce the number of complications compared with conventional pulmonary angiography. The procedure is rapidly performed and the diagnostic accuracy high. This makes digital subtraction angiography cost effective. Digital pulmonary angiography can be recommended as the primary diagnostic method in most patients with possible pulmonary embolism. (orig.)

  3. Examination of the lumbar vertebral column using large-screen image intensifier photofluorography

    International Nuclear Information System (INIS)

    Soimakallio, S.; Manninen, H.; Mahlamaeki, S.; Kuopio Central Hospital

    1985-01-01

    The OPTILUX 57 device with its large image intensifying screen is very efficient in visualizing the lumbar vertebrae. The article explains the techniques and summarizes results obtained in the examination of young sportsmen. (orig.) [de

  4. An alternative approach to contrast-detail testing of X-ray image intensifier systems

    International Nuclear Information System (INIS)

    Kotre, C.J.; Marshall, N.W.; Faulkner, K.

    1992-01-01

    The difficulties of making the results of threshold contrast-detail diameter tests on X-ray image intensifier systems consistent with published performance standards are discussed. The current approach to contrast-detail testing is described and an alternative method intended to give greater consistency for all image intensifier input field diameters proposed. The current and alternative test conditions are compared on two image intensifier systems. The results obtained show that the contrast-detail curves for image intensifier systems with a wide range of input field diameters can be effectively normalized to be directly comparable to a common reference standard by applying the proposed alternative test conditions. The implications of this result on the interpretation of the contrast-detail test are discussed. (author)

  5. A year's experience with a 57 cm image intensifier in a general X-ray room

    International Nuclear Information System (INIS)

    Georgi, M.; Prager, P.; Busch, H.P.; Strauss, L.; Wetzel, E.; Neumann, D.; Weiher, M.; Regenfuss, W.

    1985-01-01

    3342 patients were examined by means of a 57 cm image intensifier during one year. The installation permits examination with the patient standing or lying. The resolution was measured with a lead grid under conditions resembling actual practice and were found to be similar to those obtained with angiographic equipment. Using a medium format technique for examining the gut and vascular system resulted in radiographic quality which was not significantly different from the use of a large format technique. For examination of the skeleton, radiographic quality, using the intensifier, was markedly poorer than that resulting from Bucky examinations. There was no diagnostic difference when carrying out lymphograms. The large intensifier window of 53 cm was particularly advantageous for DSA of the pelvic and lower limb vessels when compared with smaller intensifiers. Possible savings of film and contrast medium costs are discussed. (orig.) [de

  6. Examination of the lumbar vertebral column using large-screen image intensifier photofluorography

    Energy Technology Data Exchange (ETDEWEB)

    Soimakallio, S.; Manninen, H.; Mahlamaeki, S.

    1985-01-01

    The OPTILUX 57 device with its large image intensifying screen is very efficient in visualizing the lumbar vertebrae. The article explains the techniques and summarizes results obtained in the examination of young sportsmen.

  7. Pick up screens for x-ray image intensifier tubes employing evaporated activated scintillator layer

    International Nuclear Information System (INIS)

    Spicer, W.E.

    1976-01-01

    The present invention relates in general to methods for making pick-up screens for x-ray image intensifier tubes and, more particularly, to an improved method wherein the x-ray fluorescent phosphor screen element is formed by evaporation of an alkali metal halide material in vacuum and condensing the evaporated material on an x-ray transparent portion of the x-ray intensifier tube, whereby a curved x-ray image pick-up screen is formed which has improved quantum efficiency and resolution. Such improved x-ray image intensifier tubes are especially useful for, but not limited in use to x-ray systems and for intensifying gamma ray images obtained in applications of nuclear medicine. 7 claims, 5 drawing figures

  8. Effects of intensified training and taper on immune function

    Directory of Open Access Journals (Sweden)

    Elena Papacosta

    2013-03-01

    Full Text Available Although resting immune function is not very different in athletes compared with non-athletes periods of intensified training (overreaching in already well trained athletes can result in a depression of immunity in the resting state. Illness-prone athletes appear to have an altered cytokine response to antigen stimulation and exercise. Having low levels of salivary IgA secretion also makes athletes more susceptible to upper respiratory tract infections. Overtraining is associated with recurrent infections and immunodepression is common, but immune functions do not seem to be reliable markers of impending overtraining. There are several possible causes of the diminution of immune function associated with periods of heavy training. One mechanism may simply be the cumulative effects of repeated bouts of intense exercise (with or without tissue damage with the consequent elevation of stress hormones, particularly glucocorticoids such as cortisol, causing temporary inhibition of TH-1 cytokines with a relative dampening of the cell-mediated response. When exercise is repeated frequently there may not be sufficient time for the immune system to recover fully. Tapering has been described as a gradual reduction in the training load which allows the recovery of physiological capacities that were impaired by previous intensive training and permits further training-induced adaptations to occur accompanied by competition performance enhancements. The majority of the studies that have examined the recovery of immunoendocrine responses during 1-3 week tapers in trained athletes have mainly reported enhanced performance, often accompanied by increased anabolic activity, reduced physiological stress and restoration of mucosal immunity and immune function.Quando se compara a função imune, em repouso, de atletas e não atletas, não se verificam grandes diferenças. Porém, períodos de treinamento intensificado ("overreaching" em atletas bem treinados podem

  9. The construction and evaluation of a prototype system for an image intensifier-based volume computed tomography imager

    International Nuclear Information System (INIS)

    Ning, R.

    1989-01-01

    A volumetric reconstruction of a three-dimensional (3-D) object has been at the forefront of exploration in medical applications for a long time. To achieve this goal, a prototype system for an image intensifier(II)-based volume computed tomography (CT) imager has been constructed. This research has been concerned with constructing and evaluating such a prototype system by phantom studies. The prototype system consists of a fixed x-ray tube, a specially designed aluminum filter that will reduce the dynamic range of projection data, an antiscatter grid, a conventional image intensifier optically coupled to a charge-coupled device (CCC) camera, a computer controlled turntable on which phantoms are placed, a digital computer including an A/D converter and a graphic station that displays the reconstructed images. In this study, three different phantoms were used: a vascular phantom, a resolution phantom and a Humanoid reg-sign chest phantom. The direct 3-D reconstruction from the projections was performed using a cone beam algorithm and vascular reconstruction algorithms. The image performance of the system for the direct 3-D reconstruction was evaluated. The spatial resolution limits of the system were estimated through observing the reconstructed images of the resolution phantom. By observing the images reconstructed from the projections, it can be determined that the image performance of the prototype system for a direct 3-D reconstruction is reasonably good and that the vascular reconstruction algorithms work very well. The results also indicate that the 3-D reconstructions obtained with the 11-based volume CT imager have nearly equally good resolution in x, y and z directions and are superior to a conventional CT in the resolution of the z direction

  10. Digital radiography: Present detectors and future developments

    International Nuclear Information System (INIS)

    Perez-Mendez, V.

    1990-08-01

    Present detectors for digital radiography are of two classes: real time detectors and storage (non real time) types. Present real time detectors consist of image intensifier tubes with an internal cesium iodide layer x-ray converter. Non real time detectors involve linear sweep arrays or storage detectors such as film. Future detectors discussed here can be of both types utilizing new technologies such as hydrogenated amorphous silicon photodiode arrays coupled to thin film transistor arrays. 17 refs., 10 figs

  11. Tomosynthesis applied to digital subtraction angiography

    International Nuclear Information System (INIS)

    Kruger, R.A.; Sedaghati, M.; Roy, D.G.; Liu, P.; Nelson, J.A.; Kubal, W.; Del Rio, P.

    1984-01-01

    This extension of the author's previous work on tomographic digital subtraction angiography (DSA) describes the theory of tomosynthetic DSA image reconstruction techniques. In addition to developing the resolution limits resulting from x-ray exposure length and image intensifier field curvature, the authors describe one method of image formation and show tomosynthetic DSA images of animal and human anatomy. Methods for improving the present technique are discussed

  12. The Future of Digital Working: Knowledge Migration and Learning

    Science.gov (United States)

    Malcolm, Irene

    2014-01-01

    Against the backdrop of intensified migration linked to globalisation, this article considers the implications of knowledge migration for future digital workers. It draws empirically on a socio-material analysis of the international software localisation industry. Localisers' work requires linguistic, cultural and software engineering skills to…

  13. Sports Digitalization : An Overview and A Research Agenda

    NARCIS (Netherlands)

    Xiao, Xiao; Chian Tan, Felix Ter; Lim, Eric T.K.; Henningsson, Stefan; Vatrapu, Ravi; Hedman, Jonas; Tan, Chee Wee; Clemenson, Torkil; Mukkamala, Raghava Rao; Van Hillegersberg, Jos

    2018-01-01

    Ever since its first manifesto in Greece around 3000 years ago, sports as a field has accumulated a long history with strong traditions while at the same time, gone through tremendous changes toward professionalization and commercialization. The current waves of digitalization have intensified its

  14. Forecast simulation of rapidly-intensified typhoon in the Eddy-Rich Northwest Pacific region

    Science.gov (United States)

    Kim, Kyeong Ok; Yuk, Jin-Hee; Jung, Kyung Tae; Kuh Kang, Suk

    2017-04-01

    The real-time typhoon predictions in the Northwest Pacific (NWP) are being distributed by various agencies (for example, KMA, JMA, JTWC, NMC, CWB, HKO and PAGASA). Currently the movement of the typhoon can be predicted with an error of less than 100 km in 48 hours, however it is difficult to the predict of the intensity of the typhoon especially the Rapidly Intensified (RI) Typhoons. The mean occurrence of RI typhoon amounts to 5.4 times a year during 39 years (1977-2015), occupying 21% of typhoons in NWP. Especially the RI typhoon in the Eddy-Rich Northwest Pacific (ER-NWP) occurred 1.8 times a year, covering 29% of typhoons in ER-NWP. A RI typhoon, NEPARTAK (T201601), occurred in July 2016. It was formed in Caroline Islands and moved northwest, straightly heading for Taiwan. However, at the beginning stage many forecasting agencies predicts as move to the Yellow Sea. The accuracy of prediction data of the Typhoon NEPARTAK (T201601) from KMA, JMA and JTWC was compared with the adjusted best-track data from Digital-Typhoon (JMA-RSMC). The sequential prediction data are summarized with 6-hour interval from 3th to 10th July 2016.The JMA prediction of the typhoon track and the JTWC predictions of the maximum wind speed were found to be best. The numerical simulations using WRF model forced with NCEP GFS prediction data and microwave SST is compared. The simulations using one domain (D1), two domains (D2) using a moving nest scheme, and with or without the spectral nudging (-SN) are compared. Comparison of the errors on the track shows the differences of 100 km in 48-hour prediction and200 km in 72-hour prediction on average. The best results on the track prediction are shown in the D2 case of WRF model. However, underestimation of the maximum wind speed of WRF prediction still exists, obviously requiring better understanding of RI-related processes to improve the model prediction.

  15. Experimental and computational investigations of heat and mass transfer of intensifier grids

    International Nuclear Information System (INIS)

    Kobzar, Leonid; Oleksyuk, Dmitry; Semchenkov, Yuriy

    2015-01-01

    The paper discusses experimental and numerical investigations on intensification of thermal and mass exchange which were performed by National Research Centre ''Kurchatov Institute'' over the past years. Recently, many designs of heat mass transfer intensifier grids have been proposed. NRC ''Kurchatov Institute'' has accomplished a large scope of experimental investigations to study efficiency of intensifier grids of various types. The outcomes of experimental investigations can be used in verification of computational models and codes. On the basis of experimental data, we derived correlations to calculate coolant mixing and critical heat flux mixing in rod bundles equipped with intensifier grids. The acquired correlations were integrated in subchannel code SC-INT.

  16. Fabry-Perot interferometry using an image-intensified rotating-mirror streak camera

    International Nuclear Information System (INIS)

    Seitz, W.L.; Stacy, H.L.

    1983-01-01

    A Fabry-Perot velocity interferometer system is described that uses a modified rotating mirror streak camera to recrod the dynamic fringe positions. A Los Alamos Model 72B rotating-mirror streak camera, equipped with a beryllium mirror, was modified to include a high aperture (f/2.5) relay lens and a 40-mm image-intensifier tube such that the image normally formed at the film plane of the streak camera is projected onto the intensifier tube. Fringe records for thin (0.13 mm) flyers driven by a small bridgewire detonator obtained with a Model C1155-01 Hamamatsu and Model 790 Imacon electronic streak cameras are compared with those obtained with the image-intensified rotating-mirror streak camera (I 2 RMC). Resolution comparisons indicate that the I 2 RMC gives better time resolution than either the Hamamatsu or the Imacon for total writing times of a few microseconds or longer

  17. State of development and development trends of X-ray image intensifier television systems

    International Nuclear Information System (INIS)

    Pfeiler, M.; Haendle, J.

    1975-01-01

    Following a survey on the development of X-ray image intensifier television systems up to now, their further development is critically discussed with regard to the better image quality to be expected. The introduction of the high-resolving X-ray image intensifier already meant an improvement in image quality even though the television system remained the same. In the image intensifier television system, the distinguishability of small details suffers from noise effects. Therefore, a better image quality is especially advantageous in those ranges of application which allow a higher picture dose. 'Electronic' radiography, intermittent screening, co-storage of the spotfilm radiographs, videometry, video area kymography, and cardiac stroboscopy are examples some of which have already been tested in clinical practice. (orig./AK) [de

  18. Change of characteristic curves using light emission spectrum of the intensifying screens

    International Nuclear Information System (INIS)

    Yoon, Chul Ho; Kang, Hong Seok; Lee, In Ja; Huh, Joon

    1990-01-01

    This report is study about difference of H-D curve in regular film and ortho type film, and obtained results as follows: 1. In the blue-color emission intensifying screen, ortho type films and in the green-color emission intensifying screens, regular type are decreased in their gradient. 2. When joint use of regular type film and ortho type film, the gradient difference not seen in blue color screen. 3. The gradient difference seen clearly in G4, KM screens (green color emission intensifying). Especially, in part of high film density, the gradient difference are great. So we have to right use of screen and film because not matched used of there the sensitivity and gradient are decrease

  19. Digital radiography

    International Nuclear Information System (INIS)

    Brody, W.R.

    1984-01-01

    Digital Radiography begins with an orderly introduction to the fundamental concepts of digital imaging. The entire X-ray digital imagining system is described, from an overall characterization of image quality to specific components required for a digital radiographic system. Because subtraction is central to digital radiographic systems, the author details the use of various subtraction methods for image enhancement. Complex concepts are illustrated with numerous examples and presented in terms that can readily be understood by physicians without an advanced mathematics background. The second part of the book discusses implementations and applications of digital imagining systems based on area and scanned detector technologies. This section includes thorough coverage of digital fluoroscopy, scanned projection radiography, and film-based digital imaging systems, and features a state-of-the-art synopsis of the applications of digital subtraction angiography. The book concludes with a timely assessment of anticipated technological advances

  20. Searching for Digital Citizenship: Fighting Corruption in Banten, Indonesia

    Directory of Open Access Journals (Sweden)

    Muhammad Zamzam Fauzanafi

    2016-12-01

    Full Text Available The expansion of digital technologies and social media in Indonesia shifts practices of citizenship from a formal institutional level toward a more informal digital space. This paper presents the emerging results of research on digital citizenship in Banten, Indonesia, focusing on how new forms of citizenship are brought into being through digital acts that are defined as speech acts uttered through the use of social media. The paper follows digital acts of citizens in anti-corruption campaigns against the patrimonial and clientelistic regime of Banten’s political dynasty that are predominantly staged on Facebook and other online platforms. These digital acts produce and intensify affective publics through which forms of digital citizenship are enacted in opposition to the corrupt dynasty.

  1. Digital Radiography in Kenya today

    International Nuclear Information System (INIS)

    Omenta, E.N.

    2006-01-01

    Its nearly one year and a half since digital imaging/radiography was introduced in Kenya mainly in Nairobi. the technology is becoming an increasingly effective and acceptable modality of producing radiographs from the traditional conventional radiography in use to date. the digital radiography offers numerous advantages that have been noted for the short period over the conventional way. For instance radiographs are produced in real time (less than 3 minutes), by so doing the technology has eliminated the wait for the processing period. the radiation exposure to the patient under the radiological examination is reduced as much as 90% from the traditional conventional film taking. The cost, labour and record-keeping necessary to maintain a chemical processor and darkroom operations are as well eliminated. The cost of purchasing and disposing of film wastes/darkroom processing chemicals, which are environmentally hazardous, also become unnecessary.digital radiography technology makes the digital images comparable to other images on the screen at that instant making both the patient and the clinician easily access images when needed. digital receptors have also replaced the cassette containing intensifying screens and film that is used in conventional radiography

  2. High-speed videography combined with an x-ray image intensifier for dynamic radiography

    International Nuclear Information System (INIS)

    Bryant, L.E. Jr.

    1983-01-01

    The Spin Physics SP-2000 high-speed video system can be combined with an x-ray source, a dynamic event having internal (not directly visible) movement and an x-ray image intensifier to perform dynamic radiography. The cesium iodide input fluor and P-20 output fluor of the image intensifier have rapid decay to allow x-ray imaging up to 12,000 pictures per second. Applications of this technique include internal functioning of a compressor, turbulent-water action, and other mechanical actions

  3. Large-field image intensifiers versus conventional chest radiography: ROC study with simulated interstitial disease

    International Nuclear Information System (INIS)

    Winter, L.H.L.; Chakraborty, D.P.; Waes, P.F.G.M.

    1988-01-01

    Two image intensifier tubes have recently been introduced whose large imaging area makes them suitable for chest imaging (Phillips Pulmodiagnost TLX slit II and Siemens TX 57 large entrance field II). Both modalities present a 10 x 10-cm hard copy image to the radiologist. A receiver operating characteristic (ROC) curve study with simulated interstitial disease was performed to compare the image quality of these image intensifiers with conventional chest images. The relative ranking in terms of decreasing ROC areas was Siemens, conventional, and Philips. Compared with conventional imaging, none of the differences in ROC curve area were statistically significant at the 5% level

  4. An intensified esterification process of palm oil fatty acid distillate catalyzed by delipidated rice bran lipase.

    Science.gov (United States)

    Chong, Fui Chin; Tey, Beng Ti; Dom, Zanariah Mohd; Ibrahim, Nordin; Rahman, Russly Abd; Ling, Tau Chuan

    2006-09-07

    An intensified esterification process was operated by circulating 10 l of reaction mixtures, consisting of palm oil fatty acid distillate (PFAD) and glycerol in hexane, through a packed-bed reactor (PBR) filled with 10 kg of delipidated rice bran lipase (RBL). The influence of the process parameters, such as reaction temperature and type of water-removal agent, on the performance of this intensified esterification process were investigated. The highest degree of esterification (61%) was achieved at a reaction temperature of 65 masculineC, using silica gels as the water-removal agent. Thin-layer chromatography (TLC) analysis showed that the major composition of the esterified product was diacylglycerol.

  5. Digital Culture and Digital Library

    Directory of Open Access Journals (Sweden)

    Yalçın Yalçınkaya

    2016-12-01

    Full Text Available In this study; digital culture and digital library which have a vital connection with each other are examined together. The content of the research consists of the interaction of culture, information, digital culture, intellectual technologies, and digital library concepts. The study is an entry work to integrity of digital culture and digital library theories and aims to expand the symmetry. The purpose of the study is to emphasize the relation between the digital culture and digital library theories acting intersection of the subjects that are examined. Also the perspective of the study is based on examining the literature and analytical evaluation in both studies (digital culture and digital library. Within this context, the methodology of the study is essentially descriptive and has an attribute for the transmission and synthesis of distributed findings produced in the field of the research. According to the findings of the study results, digital culture is an inclusive term that describes the effects of intellectual technologies in the field of information and communication. Information becomes energy and the spectrum of the information is expanding in the vertical rise through the digital culture. In this context, the digital library appears as a new living space of a new environment. In essence, the digital library is information-oriented; has intellectual technology support and digital platform; is in a digital format; combines information resources and tools in relationship/communication/cooperation by connectedness, and also it is the dynamic face of the digital culture in time and space independence. Resolved with the study is that the digital libraries are active and effective in the formation of global knowing and/or mass wisdom in the process of digital culture.

  6. Digital mammography; Mamografia digital

    Energy Technology Data Exchange (ETDEWEB)

    Chevalier, M.; Torres, R.

    2010-07-01

    Mammography represents one of the most demanding radiographic applications, simultaneously requiring excellent contrast sensitivity, high spatial resolution, and wide dynamic range. Film/screen is the most widely extended image receptor in mammography due to both its high spatial resolution and contrast. The film/screen limitations are related with its narrow latitude, structural noise and that is at the same time the medium for the image acquisition, storage and presentation. Several digital detector made with different technologies can overcome these difficulties. Here, these technologies as well as their main advantages and disadvantages are analyzed. Also it is discussed its impact on the mammography examinations, mainly on the breast screening programs. (Author).

  7. Digital Tectonics

    DEFF Research Database (Denmark)

    Christiansen, Karl; Borup, Ruben; Søndergaard, Asbjørn

    2014-01-01

    Digital Tectonics treats the architectonical possibilities in digital generation of form and production. The publication is the first volume of a series, in which aspects of the strategic focus areas of the Aarhus School of Architecture will be disseminated.......Digital Tectonics treats the architectonical possibilities in digital generation of form and production. The publication is the first volume of a series, in which aspects of the strategic focus areas of the Aarhus School of Architecture will be disseminated....

  8. Digital squares

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Kim, Chul E

    1988-01-01

    Digital squares are defined and their geometric properties characterized. A linear time algorithm is presented that considers a convex digital region and determines whether or not it is a digital square. The algorithm also determines the range of the values of the parameter set of its preimages....... The analysis involves transforming the boundary of a digital region into parameter space of slope and y-intercept...

  9. Digital skrivedidaktik

    DEFF Research Database (Denmark)

    Digital skrivedidaktik består af to dele. Første del præsenterer teori om skrivekompetence og digital skrivning. Digital skrivning er karakteriseret ved at tekster skrives på computer og med digitale værktøjer, hvilket ændrer skrivningens traditionelle praksis, produkt og processer. Hvad er digital...... om elevens skriveproces) og Blogskrivning (der styrker eleverne i at bruge blogs i undervisningen)....

  10. Digital Citizenship

    Science.gov (United States)

    Isman, Aytekin; Canan Gungoren, Ozlem

    2014-01-01

    Era in which we live is known and referred as digital age.In this age technology is rapidly changed and developed. In light of these technological advances in 21st century, schools have the responsibility of training "digital citizen" as well as a good citizen. Digital citizens must have extensive skills, knowledge, Internet and …

  11. Pseudo real-time coded aperture imaging system with intensified vidicon cameras

    International Nuclear Information System (INIS)

    Han, K.S.; Berzins, G.J.

    1977-01-01

    A coded image displayed on a TV monitor was used to directly reconstruct a decoded image. Both the coded and the decoded images were viewed with intensified vidicon cameras. The coded aperture was a 15-element nonredundant pinhole array. The coding and decoding were accomplished simultaneously during the scanning of a single 16-msec TV frame

  12. Monte-Carlo simulation of spatial resolution of an image intensifier in a saturation mode

    Science.gov (United States)

    Xie, Yuntao; Wang, Xi; Zhang, Yujun; Sun, Xiaoquan

    2018-04-01

    In order to investigate the spatial resolution of an image intensifier which is irradiated by high-energy pulsed laser, a three-dimensional electron avalanche model was built and the cascade process of the electrons was numerically simulated. The influence of positive wall charges, due to the failure of replenishing charges extracted from the channel during the avalanche, was considered by calculating its static electric field through particle-in-cell (PIC) method. By tracing the trajectory of electrons throughout the image intensifier, the energy of the electrons at the output of the micro channel plate and the electron distribution at the phosphor screen are numerically calculated. The simulated energy distribution of output electrons are in good agreement with experimental data of previous studies. In addition, the FWHM extensions of the electron spot at phosphor screen as a function of the number of incident electrons are calculated. The results demonstrate that the spot size increases significantly with the increase in the number of incident electrons. Furthermore, we got the MTFs of the image intensifier by Fourier transform of a point spread function at phosphor screen. Comparison between the MTFs in our model and the MTFs by analytic method shows that spatial resolution of the image intensifier decreases significantly as the number of incident electrons increases, and it is particularly obvious when incident electron number greater than 100.

  13. Assessing impacts of intensified biomass production and biodiversity protection on ecosystem services provided by European forests

    NARCIS (Netherlands)

    Verkerk, P.J.; Mavsar, R.; Giergiczny, M.; Lindner, M.; Edwards, D.; Schelhaas, M.J.

    2014-01-01

    To develop viable strategies for intensifying the use of forest biomass and for increasing forest protection, impacts on ecosystem services need to be assessed. We investigated the biophysical and economic impacts of increased forest biomass production and biodiversity protection on forest ecosystem

  14. Dust visualisation in TJ-II with intensified visible fast cameras

    International Nuclear Information System (INIS)

    Cal, E. de la; Pablos, J. L. de; Carralero, D.; Hidalgo, C.

    2010-01-01

    A visible fast camera equipped with an image Intensifier and atomic line filters is used in TJ-II for spectroscopic dust observation. First results show characteristic features depending on filter and clearly differing from those without the filters as is usually done in existing experiments. Preliminary discussions of the observed results are presented. (Author) 5 refs.

  15. Reemergence of Mycobacterium chimaera in Heater–Cooler Units despite Intensified Cleaning and Disinfection Protocol

    Science.gov (United States)

    Schreiber, Peter W.; Kuster, Stefan P.; Hasse, Barbara; Bayard, Cornelia; Rüegg, Christian; Kohler, Philipp; Keller, Peter M.; Bloemberg, Guido V.; Maisano, Francesco; Bettex, Dominique; Halbe, Maximilian; Sommerstein, Rami

    2016-01-01

    Invasive Mycobacterium chimaera infections after open-heart surgery have been reported internationally. These devastating infections result from aerosols generated by contaminated heater–cooler units used with extracorporeal circulation during surgery. Despite intensified cleaning and disinfection, surveillance samples from factory-new units acquired during 2014 grew nontuberculous mycobacteria after a median of 174 days. PMID:27649345

  16. Control of a Biological Nitrogen Removal Process in an Intensified Single Reactor Configuration

    DEFF Research Database (Denmark)

    Vangsgaard, Anna Katrine; Mauricio Iglesias, Miguel; Gernaey, Krist

    2013-01-01

    The nitrogen removing granular sludge process is a novel and intensified process. However, its stable operation and control remains a challenging problem. In this contribution, a new process oriented approach is used to develop, evaluate and benchmark control strategies to ensure stable operation...

  17. Intensified Voice Therapy: A New Model for the Rehabilitation of Patients Suffering from Functional Dysphonias

    Science.gov (United States)

    Fischer, Michael J.; Gutenbrunner, Christoph; Ptok, Martin

    2009-01-01

    The objective of this study was to evaluate a new intervention for chronic dysphonias, consisting of a 2-week outpatient treatment period using intensified voice therapy combined with elements of physical medicine, including physiotherapy (orthotherapy, detonisation and training of the trunk muscles, respiratory therapy and others), manual therapy…

  18. Dust visualisation in TJ-II with intensified visible Fast Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Cal, E. de la; Pablos, J. L. de; Carralero, D.; Hidalgo, C.

    2010-10-21

    A visible fast camera equipped with an image Intensifier and atomic line filters is used in TJ-II for spectroscopic dust observation. First results show characteristic features depending on filter and clearly differing from those without the filters as is usually done in existing experiments. Preliminary discussions of the observed results are presented. (Author) 5 refs.

  19. Investigating the Effectiveness of Audio Input Enhancement on EFL Learners' Retention of Intensifiers

    Science.gov (United States)

    Negari, Giti Mousapour; Azizi, Aliye; Arani, Davood Khedmatkar

    2018-01-01

    The present study attempted to investigate the effects of audio input enhancement on EFL learners' retention of intensifiers. To this end, two research questions were formulated. In order to address these research questions, this study attempted to reject two null hypotheses. Pretest-posttest control group quasi-experimental design was employed to…

  20. Public Narratives under Intensified Market Conditions: Chile as a Critical Case

    Science.gov (United States)

    Santori, Diego

    2018-01-01

    This paper aims to extend existing theorisations around the notion of public narratives by analysing their regulatory effects under intensified market conditions. My analysis suggests that public narratives constitute a liminal space, one that it is not exclusively real or imaginary, factual or normative, but that simultaneously affects and is…

  1. Simulation of dental intensifying screen for intraoral radiographic using MCNP5 code

    International Nuclear Information System (INIS)

    Ferreira, Vanessa M.; Oliveira, Renato C.M.; Barros, Graiciany P.; Oliveira, Arno H.; Veloso, M. Auxiliadora F.

    2011-01-01

    One of basic principles for radiological protection is the optimization of techniques for obtain radiographic images, in way that the dose in the patient is kept as low as reasonably achievable (ALARA). Intensifying screens are used in medical radiology, which reduce considerably the dose rates in the production of radiographic images, maintaining the quality of these, while in dental radiology, there is no a intensifying screen available for intraoral examinations. From this technological requirement, this paper evaluates a computational modeling of an intensifying screen for use in intraoral radiography. For this, it was used the Monte Carlo code MCNP5 that allows the radiography simulation through the transport of electrons and photons in the different materials present in this examination. The goal of an intensifying screen is the conversion of X-ray photons to photons in the visible spectrum, knowing that radiographic films are more sensitive to light photons than to X-ray photons. So the screen should be composed of an efficient material for converting x-rays photons in light photons, therefore was made simulations using different materials, thicknesses and positions possible for placing screen in radiographic film in order to find the way more technically feasible. (author)

  2. Reemergence of Mycobacterium chimaera in Heater-Cooler Units despite Intensified Cleaning and Disinfection Protocol.

    Science.gov (United States)

    Schreiber, Peter W; Kuster, Stefan P; Hasse, Barbara; Bayard, Cornelia; Rüegg, Christian; Kohler, Philipp; Keller, Peter M; Bloemberg, Guido V; Maisano, Francesco; Bettex, Dominique; Halbe, Maximilian; Sommerstein, Rami; Sax, Hugo

    2016-10-01

    Invasive Mycobacterium chimaera infections after open-heart surgery have been reported internationally. These devastating infections result from aerosols generated by contaminated heater-cooler units used with extracorporeal circulation during surgery. Despite intensified cleaning and disinfection, surveillance samples from factory-new units acquired during 2014 grew nontuberculous mycobacteria after a median of 174 days.

  3. Influence of range-gated intensifiers on underwater imaging system SNR

    Science.gov (United States)

    Wang, Xia; Hu, Ling; Zhi, Qiang; Chen, Zhen-yue; Jin, Wei-qi

    2013-08-01

    Range-gated technology has been a hot research field in recent years due to its high effective back scattering eliminating. As a result, it can enhance the contrast between a target and its background and extent the working distance of the imaging system. The underwater imaging system is required to have the ability to image in low light level conditions, as well as the ability to eliminate the back scattering effect, which means that the receiver has to be high-speed external trigger function, high resolution, high sensitivity, low noise, higher gain dynamic range. When it comes to an intensifier, the noise characteristics directly restrict the observation effect and range of the imaging system. The background noise may decrease the image contrast and sharpness, even covering the signal making it impossible to recognize the target. So it is quite important to investigate the noise characteristics of intensifiers. SNR is an important parameter reflecting the noise features of a system. Through the use of underwater laser range-gated imaging prediction model, and according to the linear SNR system theory, the gated imaging noise performance of the present market adopted super second generation and generation Ⅲ intensifiers were theoretically analyzed. Based on the active laser underwater range-gated imaging model, the effect to the system by gated intensifiers and the relationship between the system SNR and MTF were studied. Through theoretical and simulation analysis to the image intensifier background noise and SNR, the different influence on system SNR by super second generation and generation Ⅲ ICCD was obtained. Range-gated system SNR formula was put forward, and compared the different effect influence on the system by using two kind of ICCDs was compared. According to the matlab simulation, a detailed analysis was carried out theoretically. All the work in this paper lays a theoretical foundation to further eliminating back scattering effect, improving

  4. Digital subtraktion

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder

    2004-01-01

    Digital subtraktion er en metode til at fjerne uønskede oplysninger i et røntgenbillede. Subtraktionsteknikken bruges primært i forbindelse med angiografi hvor man kun er interesseret i at se selve karret. Derfor er digital subtraktion i daglig tale synonymt med DSA eller DVI – hhv. Digital...... Subtraction Angiography eller Digital Vascular Imaging. Benævnelserne er to røntgenfirmaers navn for den samme teknik. Digital subtraktion kræver speciel software, samt at apparaturet kan eksponere i serier....

  5. Digital preservation

    CERN Document Server

    Deegan, Marilyn

    2013-01-01

    Digital preservation is an issue of huge importance to the library and information profession right now. With the widescale adoption of the internet and the rise of the world wide web, the world has been overwhelmed by digital information. Digital data is being produced on a massive scale by individuals and institutions: some of it is born, lives and dies only in digital form, and it is the potential death of this data, with its impact on the preservation of culture, that is the concern of this book. So how can information professionals try to remedy this? Digital preservation is a complex iss

  6. Image processing in digital chest radiography

    International Nuclear Information System (INIS)

    Manninen, H.; Partanen, K.; Lehtovirta, J.; Matsi, P.; Soimakallio, S.

    1992-01-01

    The usefulness of digital image processing of chest radiographs was evaluated in a clinical study. In 54 patients, chest radiographs in the posteroanterior projection were obtained by both 14 inch digital image intensifier equipment and the conventional screen-film technique. The digital radiographs (512x512 image format) viewed on a 625 line monitor were processed in 3 different ways: 1.standard display; 2.digital edge enhancement for the standard display; 3.inverse intensity display. The radiographs were interpreted independently by 3 radiologists. Diagnoses were confirmed by CT, follow-up radiographs and clinical records. Chest abnormalities of the films analyzed included 21 primary lung tumors, 44 pulmonary nodules, 16 cases with mediastinal disease, 17 with pneumonia /atelectasis. Interstitial lung disease, pleural plaques, and pulmonary emphysema were found in 30, 18 and 19 cases respectively. Sensitivity of conventional radiography when averaged overall findings was better than that of digital techniques (P<0.001). Differences in diagnostic accuracy measured by sensitivity and specificity between the 3 digital display modes were small. Standard image display showed better sensitivity for pulmonary nodules (0.74 vs 0.66; P<0.05) but poorer specificity for pulmonary emphysema (0.85 vs 0.93; P<0.05) compared with inverse intensity display. It is concluded that when using 512x512 image format, the routine use of digital edge enhancement and tone reversal at digital chest radiographs is not warranted. (author). 12 refs.; 4 figs.; 2 tabs

  7. Digital Natives or Digital Tribes?

    Science.gov (United States)

    Watson, Ian Robert

    2013-01-01

    This research builds upon the discourse surrounding digital natives. A literature review into the digital native phenomena was undertaken and found that researchers are beginning to identify the digital native as not one cohesive group but of individuals influenced by other factors. Primary research by means of questionnaire survey of technologies…

  8. Digital subtraction arthrography of the hips and of the shoulders

    International Nuclear Information System (INIS)

    Fink, B.K.; Schedel, J.; Fink, U.; Hansen, M.; Hilbertz, T.; Hagena, F.W.

    1991-01-01

    In a study on 60 patients, it could be shown that very good results can be achieved in the region of the shoulder joint with the use of the digital subtraction technique and of digital image intensifier radiography. A further possibility of using the digital subtraction technique for proving endoprosthesis loosenings of the hip demonstrated its importance after a short time and has become a routine method in the meantime. These two examination techniques are displayed methodologically and their clinical possibilities of use are assessed in this contribution. (orig.)

  9. Method and apparatus for performing digital intravenous subtraction angiography

    International Nuclear Information System (INIS)

    Stein, J.A.

    1986-01-01

    This invention relates to digital intravenous subtraction angiography (DISA), and more particularly concerns novel apparatus and techniques for providing high resolution angiograms with equipment that coacts with existing standard medical X-ray equipment. A typical medical X-ray generator provides low mA, continuous X-ray exposures illuminating a standard image intensifier producing an image scanned by a conventional television camera to produce a video signal. An analog-to-digital converter digitizes the signal, and adding means adds the digital frame signals together in real time to provide an intermediate digital signal representing the addition of 5 to 20 frames. Digital storage means store the intermediate image signals. Preferably there are two system memories with means for summing a subsequent intermediate image in the second memory while a previously-formed intermediate image is being transferred to disk storage

  10. Improved pregnancy outcome in type 1 diabetic women with microalbuminuria or diabetic nephropathy: effect of intensified antihypertensive therapy?

    DEFF Research Database (Denmark)

    Nielsen, Lene Ringholm; Damm, Peter; Mathiesen, Elisabeth R

    2009-01-01

    To describe pregnancy outcome in type 1 diabetic women with normoalbuminuria, microalbuminuria, or diabetic nephropathy after implementation of an intensified antihypertensive therapeutic strategy.......To describe pregnancy outcome in type 1 diabetic women with normoalbuminuria, microalbuminuria, or diabetic nephropathy after implementation of an intensified antihypertensive therapeutic strategy....

  11. Digital mammography

    International Nuclear Information System (INIS)

    Bick, Ulrich; Diekmann, Felix

    2010-01-01

    This state-of-the-art reference book provides in-depth coverage of all aspects of digital mammography, including detector technology, image processing, computer-aided diagnosis, soft-copy reading, digital workflow, and PACS. Specific advantages and disadvantages of digital mammography in comparison to screen-film mammography are thoroughly discussed. By including authors from both North America and Europe, the book is able to outline variations in the use, acceptance, and quality assurance of digital mammography between the different countries and screening programs. Advanced imaging techniques and future developments such as contrast mammography and digital breast tomosynthesis are also covered in detail. All of the chapters are written by internationally recognized experts and contain numerous high-quality illustrations. This book will be of great interest both to clinicians who already use or are transitioning to digital mammography and to basic scientists working in the field. (orig.)

  12. Digital Insights

    DEFF Research Database (Denmark)

    Knudsen, Gry Høngsmark

    , by incorporating media as both channel, frame, and apparatus for advertising response, the dissertation brings into attention that more aspects than the text-reader relationship influence ad response. Finally, the dissertation proposes the assemblage approach for exploring big data in consumer culture research...... and practices with digital media, when they meet and interpret advertising. Through studies of advertising response on YouTube and experiments with consumers’ response to digitally manipulated images, the dissertation shows how digital media practices facilitate polysemic and socially embedded advertising......This dissertation forwards the theory of digital consumer-response as a perspective to examine how digital media practices influence consumers’ response to advertising. Digital consumer-response is a development of advertising theory that encompasses how consumers employ their knowledge...

  13. Digital Signage

    OpenAIRE

    Fischer, Karl Peter

    2011-01-01

    Digital Signage for in-store advertising at gas stations/retail stores in Germany: A field study Digital Signage networks provide a novel means of advertising with the advantage of easily changeable and highly customizable animated content. Despite the potential and increasing use of these media empirical research is scarce. In a field study at 8 gas stations (with integrated convenience stores) we studied the effect of digital signage advertising on sales for different products and servi...

  14. Application of ultra-fast high-resolution gated-image intensifiers to laser fusion studies

    International Nuclear Information System (INIS)

    Lieber, A.J.; Benjamin, R.F.; Sutphin, H.D.; McCall, G.H.

    1975-01-01

    Gated-image intensifiers for fast framing have found high utility in laser-target interaction studies. X-ray pinhole camera photographs which can record asymmetries of laser-target interactions have been instrumental in further system design. High-resolution high-speed x-ray images of laser irradiated targets are formed using pinhole optics and electronically amplified by proximity focused channelplate intensifiers before being recorded on film. Spectral resolution is obtained by filtering. In these applications shutter duration is determined by source duration. Electronic gating serves to reduce background thereby enhancing signal-to-noise ratio. Cameras are used to view the self light of the interaction but may also be used for shadowgraphs. Sources for shadowgraphs may be sequenced to obtain a series of pictures with effective rates of 10 10 frame/s. Multiple aperatures have been used to obtain stereo x-ray views, yielding three dimensional information about the interactions. (author)

  15. Avalanche transistor pulser for fast-gated operation of micro-channel plate image-intensifiers

    International Nuclear Information System (INIS)

    Lundy, A.; Parker, J.R.; Lunsford, J.S.; Martin, A.D.

    1977-01-01

    Transistors operated in the avalanche mode are employed to generate a 1000 volt 10 to 30 nsec wide pulse with less than 4 nsec rise and fall times. This pulse is resistively attenuated to approximately equal to 270 volts and drives the image intensifier tube which is a load of approximately equal to 200 pf. To reduce stray inductance and capacitance, transistor chips were assembled on a thick-film hybrid substrate. Circuit parameters, operating conditions, and coupling to the microchannel plate image-intensifier (MCPI 2 ) tube are described. To provide dc operating voltages and control of transient voltages on the MCPI 2 tube a resistance-capacitance network has been developed which (a) places the MCPI 2 output phosphor at ground, (b) provides programmable gains in ''f-stop'' steps, and (c) minimizes voltage transients on the MCPI 2 tube

  16. Weakened cyclones, intensified anticyclones and recent extreme cold winter weather events in Eurasia

    International Nuclear Information System (INIS)

    Zhang Xiangdong; Lu Chuhan; Guan Zhaoyong

    2012-01-01

    Extreme cold winter weather events over Eurasia have occurred more frequently in recent years in spite of a warming global climate. To gain further insight into this regional mismatch with the global mean warming trend, we analyzed winter cyclone and anticyclone activities, and their interplay with the regional atmospheric circulation pattern characterized by the semi-permanent Siberian high. We found a persistent weakening of both cyclones and anticyclones between the 1990s and early 2000s, and a pronounced intensification of anticyclone activity afterwards. It is suggested that this intensified anticyclone activity drives the substantially strengthening and northwestward shifting/expanding Siberian high, and explains the decreased midlatitude Eurasian surface air temperature and the increased frequency of cold weather events. The weakened tropospheric midlatitude westerlies in the context of the intensified anticyclones would reduce the eastward propagation speed of Rossby waves, favoring persistence and further intensification of surface anticyclone systems. (letter)

  17. An Intensified Esterification Process of Palm Oil Fatty Acid Distillate Catalyzed by Delipidated Rice Bran Lipase

    Directory of Open Access Journals (Sweden)

    Fui Chin Chong

    2006-01-01

    Full Text Available An intensified esterification process was operated by circulating 10 l of reaction mixtures, consisting of palm oil fatty acid distillate (PFAD and glycerol in hexane, through a packed-bed reactor (PBR filled with 10 kg of delipidated rice bran lipase (RBL. The influence of the process parameters, such as reaction temperature and type of water-removal agent, on the performance of this intensified esterification process were investigated. The highest degree of esterification (61% was achieved at a reaction temperature of 65°C, using silica gels as the water-removal agent. Thin-layer chromatography (TLC analysis showed that the major composition of the esterified product was diacylglycerol.

  18. Sports Digitalization

    DEFF Research Database (Denmark)

    Xiao, Xiao; Hedman, Jonas; Tan, Felix Ter Chian

    2017-01-01

    evolution, as digital technologies are increasingly entrenched in a wide range of sporting activities and for applications beyond mere performance enhancement. Despite such trends, research on sports digitalization in the IS discipline is surprisingly still nascent. This paper aims at establishing...... a discourse on sports digitalization within the discipline. Toward this, we first provide an understanding of the institutional characteristics of the sports industry, establishing its theoretical importance and relevance in our discipline; second, we reveal the latest trends of digitalization in the sports...

  19. Digital printing

    Science.gov (United States)

    Sobotka, Werner K.

    1997-02-01

    Digital printing is described as a tool to replace conventional printing machines completely. Still this goal was not reached until now with any of the digital printing technologies to be described in the paper. Productivity and costs are still the main parameters and are not really solved until now. Quality in digital printing is no problem anymore. Definition of digital printing is to transfer digital datas directly on the paper surface. This step can be carried out directly or with the use of an intermediate image carrier. Keywords in digital printing are: computer- to-press; erasable image carrier; image carrier with memory. Digital printing is also the logical development of the new digital area as it is pointed out in Nicholas Negropotes book 'Being Digital' and also the answer to networking and Internet technologies. Creating images text and color in one country and publishing the datas in another country or continent is the main advantage. Printing on demand another big advantage and last but not least personalization the last big advantage. Costs and being able to coop with this new world of prepress technology is the biggest disadvantage. Therefore the very optimistic growth rates for the next few years are really nonexistent. The development of complete new markets is too slow and the replacing of old markets is too small.

  20. Improving lactate metabolism in an intensified CHO culture process: productivity and product quality considerations.

    Science.gov (United States)

    Xu, Sen; Hoshan, Linda; Chen, Hao

    2016-11-01

    In this study, we discussed the development and optimization of an intensified CHO culture process, highlighting medium and control strategies to improve lactate metabolism. A few strategies, including supplementing glucose with other sugars (fructose, maltose, and galactose), controlling glucose level at Productivity and product quality attributes differences between batch, fed-batch, and concentrated fed-batch cultures were discussed. The importance of process and cell metabolism understanding when adapting the existing process to a new operational mode was demonstrated in the study.

  1. Quality control measurements of X-ray image-intensifier television chain systems

    International Nuclear Information System (INIS)

    Henshaw, E.T.

    1989-01-01

    The test methods and limiting values for the following basic parameters of an image intensifier TV system are presented in relation to (a) acceptance tests and (b) constancy tests: automatic gain and brightness control, video voltage output, monitor check (grey scale), geometric distortion, noise (low-contrast detectability), overall imaging ability, limiting resolution, uniformity of resolution, conversion factor, contrast ratio and measurement of field size. Several of these tests make use of the Leeds Test Objects. (author)

  2. Relationship between fatigue of generation II image intensifier and input illumination

    Science.gov (United States)

    Chen, Qingyou

    1995-09-01

    If there is fatigue for an image intesifier, then it has an effect on the imaging property of the night vision system. In this paper, using the principle of Joule Heat, we derive a mathematical formula for the generated heat of semiconductor photocathode. We describe the relationship among the various parameters in the formula. We also discuss reasons for the fatigue of Generation II image intensifier caused by bigger input illumination.

  3. A directional fast neutron detector using scintillating fibers and an intensified CCD camera system

    International Nuclear Information System (INIS)

    Holslin, Daniel; Armstrong, A.W.; Hagan, William; Shreve, David; Smith, Scott

    1994-01-01

    We have been developing and testing a scintillating fiber detector (SFD) for use as a fast neutron sensor which can discriminate against neutrons entering at angles non-parallel to the fiber axis (''directionality''). The detector/convertor component is a fiber bundle constructed of plastic scintillating fibers each measuring 10 cm long and either 0.3 mm or 0.5 mm in diameter. Extensive Monte Carlo simulations were made to optimize the bundle response to a range of fast neutron energies and to intense fluxes of high energy gamma-rays. The bundle is coupled to a set of gamma-ray insenitive electro-optic intensifiers whose output is viewed by a CCD camera directly coupled to the intensifiers. Two types of CCD cameras were utilized: 1) a standard, interline RS-170 camera with electronic shuttering and 2) a high-speed (up to 850 frame/s) field-transfer camera. Measurements of the neutron detection efficiency and directionality were made using 14 MeV neutrons, and the response to gamma-rays was performed using intense fluxes from radioisotopic sources (up to 20 R/h). Recently, the detector was constructed and tested using a large 10 cm by 10 cm square fiber bundle coupled to a 10 cm diameter GEN I intensifier tube. We present a description of the various detector systems and report the results of experimental tests. ((orig.))

  4. Digital Audiobooks

    DEFF Research Database (Denmark)

    Have, Iben; Pedersen, Birgitte Stougaard

    Audiobooks are rapidly gaining popularity with widely accessible digital downloading and streaming services. The paper is framing how the digital audiobook expands and changes the target groups for book publications and how it as an everyday activity is creating new reading experiences, places...

  5. Digital TMI

    Science.gov (United States)

    Rios, Joseph

    2012-01-01

    Presenting the current status of the Digital TMI project to visiting members of the FAA Command Center. Digital TMI is an effort to store national-level traffic management initiatives in a standards-compliant manner. Work is funded by the FAA.

  6. Digital displacements

    DEFF Research Database (Denmark)

    Pors, Anja Svejgaard

    2014-01-01

    In recent years digital reforms are being introduced in the municipal landscape of Denmark. The reforms address the interaction between citizen and local authority. The aim is, that by 2015 at least 80 per cent of all correspondence between citizens and public authority will be transmitted through...... digital interface. However, the transformation of citizen services from traditional face-to-face interaction to digital self-service gives rise to new practices; some citizens need support to be able to manage self-service through digital tools. A mixture of support and teaching, named co......-service, is a new task in public administration, where street level bureaucrats assist citizens in using the new digital solutions. The paper is based on a case study conducted primarily in a citizen service centre in Copenhagen, Denmark. Based on ethnography the paper gives an empirical account of the ongoing...

  7. Digitized mammograms

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Balu-Maestro, C.; Rogopoulos, A.; Chauvel, C.; Geoffray, A.

    1988-01-01

    Two observers conducted a blind evaluation of 100 mammography files, including 47 malignant cases. Films were read both before and after image digitization at 50 μm and 100 μm with the FilmDRSII. Digitization permitted better analysis of the normal anatomic structures and moderately improved diagnostic sensitivity. Searches for microcalcifications before and after digitization at 100 μm and 50 μm showed better analysis of anatomic structures after digitization (especially for solitary microcalcifications). The diagnostic benefit, with discovery of clustered microcalcifications, was more limited (one case at 100 μm, nine cases at 50 μm). Recognition of microcalcifications was clearly improved in dense breasts, which can benefit from reinterpretation after digitization at 50 μm rather 100μm

  8. Signal-to-noise characterization of time-gated intensifiers used for wide-field time-domain FLIM

    Energy Technology Data Exchange (ETDEWEB)

    McGinty, J; Requejo-Isidro, J; Munro, I; Talbot, C B; Dunsby, C; Neil, M A A; French, P M W [Photonics Group, Blackett Laboratory, Imperial College London, Prince Consort Road, London, SW7 2BW (United Kingdom); Kellett, P A; Hares, J D, E-mail: james.mcginty@imperial.ac.u [Kentech Instruments Ltd, Isis Building, Howbery Park, Wallingford, OX10 8BA (United Kingdom)

    2009-07-07

    Time-gated imaging using gated optical intensifiers provides a means to realize high speed fluorescence lifetime imaging (FLIM) for the study of fast events and for high throughput imaging. We present a signal-to-noise characterization of CCD-coupled micro-channel plate gated intensifiers used with this technique and determine the optimal acquisition parameters (intensifier gain voltage, CCD integration time and frame averaging) for measuring mono-exponential fluorescence lifetimes in the shortest image acquisition time for a given signal flux. We explore the use of unequal CCD integration times for different gate delays and show that this can improve the lifetime accuracy for a given total acquisition time.

  9. Digital Ethics/Going Digital.

    Science.gov (United States)

    Wilson, Bradley

    1996-01-01

    Finds that the recent National Press Photographers Association code of ethics can serve as a model for any photography staff. Discusses how digital imaging is becoming commonplace in classrooms, due to decreasing costs and easier software. Explains digital terminology. Concludes that time saved in the darkroom and at the printer is now spent on…

  10. Digital radiography

    International Nuclear Information System (INIS)

    Coulomb, M.; Dal Soglio, S.; Pittet-Barbier, L.; Ranchoup, Y.; Thony, F.; Ferretti, G.; Robert, F.

    1992-01-01

    Digital projection radiography may replace conventional radiography some day, provided it can meet several requirements: equal or better diagnostic effectiveness of the screen-film systems; reasonable image cost; real improvement in the productivity of the Departments of Imaging. All digital radiographic systems include an X-ray source, an image acquisition and formatting sub-system, a display and manipulation sub-system, and archiving subsystem and a laser editing system, preferably shared by other sources of digital images. Three digitization processes are available: digitization of the radiographic film, digital fluorography and phospholuminescent detectors with memory. The advantages of digital fluoroscopy are appealing: real-time image acquisition, suppression of cassettes; but its disadvantages are far from negligible: it cannot be applied to bedside radiography, the field of examination is limited, and the wide-field spatial resolution is poor. Phospholuminescent detectors with memory have great advantages: they can be used for bedside radiographs and on all the common radiographic systems; spatial resolution is satisfactory; its current disadvantages are considerable. These two systems, have common properties making up the entire philosophy of digital radiology and specific features that must guide our choice according to the application. Digital fluorography is best applied in pediatric radiology. However, evaluation works have showed that it was applicable with sufficient quality to many indications of general radiology in which a fluoroscopic control and fast acquisition of the images are essential; the time gained on the examination may be considerable, as well as the savings on film. Detectors with memory are required for bedside radiographs, in osteoarticular and thoracic radiology, in all cases of traumatic emergency and in the resuscitation and intensive care departments

  11. Becoming digital

    DEFF Research Database (Denmark)

    Pors, Anja Svejgaard

    2015-01-01

    . An ethnographic account of how digital reforms are implemented in practice shows how street-level bureaucrat’s classic tasks such as specialized casework are being reconfigured into educational tasks that promote the idea of “becoming digital”. In the paper, the author argues that the work of “becoming digital....... Originality/value: The study contributes to ethnographic research in public administration by combining two separate subfields, e-government and street-level bureaucracy, to discern recent transformations in public service delivery. In the digital era, tasks, control and equality are distributed in ways...

  12. Digital Humanities

    DEFF Research Database (Denmark)

    Brügger, Niels

    2016-01-01

    , and preserving material to study, as an object of study in its own right, as an analytical tool, or for collaborating, and for disseminating results. The term "digital humanities" was coined around 2001, and gained currency within academia in the following years. However, computers had been used within......Digital humanities is an umbrella term for theories, methodologies, and practices related to humanities scholarship that use the digital computer as an integrated and essential part of its research and teaching activities. The computer can be used for establishing, finding, collecting...

  13. Digital Snaps

    DEFF Research Database (Denmark)

    Sandbye, Mette; Larsen, Jonas

    . Distance as the New Punctum / Mikko Villi -- pt. II. FAMILY ALBUMS IN TRANSITION -- ch. 4. How Digital Technologies Do Family Snaps, Only Better / Gillian Rose -- ch. 5. Friendship Photography: Memory, Mobility and Social Networking / Joanne Garde-Hansen -- ch. 6. Play, Process and Materiality in Japanese...... -- ch. 9. Retouch Yourself: The Pleasures and Politics of Digital Cosmetic Surgery / Tanya Sheehan -- ch. 10. Virtual Selves: Art and Digital Autobiography / Louise Wolthers -- ch. 11. Mobile-Media Photography: New Modes of Engagement / Michael Shanks and Connie Svabo....

  14. Digital electronics

    CERN Document Server

    Morris, John

    2013-01-01

    An essential companion to John C Morris's 'Analogue Electronics', this clear and accessible text is designed for electronics students, teachers and enthusiasts who already have a basic understanding of electronics, and who wish to develop their knowledge of digital techniques and applications. Employing a discovery-based approach, the author covers fundamental theory before going on to develop an appreciation of logic networks, integrated circuit applications and analogue-digital conversion. A section on digital fault finding and useful ic data sheets completes th

  15. Digital Leadership

    DEFF Research Database (Denmark)

    Zupancic, Tadeja; Verbeke, Johan; Achten, Henri

    2016-01-01

    Leadership is an important quality in organisations. Leadership is needed to introduce change and innovation. In our opinion, in architectural and design practices, the role of leadership has not yet been sufficiently studied, especially when it comes to the role of digital tools and media....... With this paper we intend to initiate a discussion in the eCAADe community to reflect and develop ideas in order to develop digital leadership skills amongst the membership. This paper introduces some important aspects, which may be valuable to look into when developing digital leadership skills....

  16. Digital radiography

    International Nuclear Information System (INIS)

    Zani, M.L.

    2002-01-01

    X-ray radiography is a very common technique used to check the homogeneity of a material or the inside of a mechanical part. Generally the radiation that goes through the material to check, produced an image on a sensitized film. This method requires time because the film needs to be developed, digital radiography has no longer this inconvenient. In digital radiography the film is replaced by digital data and can be processed as any computer file. This new technique is promising but its main inconvenient is that today its resolution is not so good as that of film radiography. (A.C.)

  17. Digital radiography

    International Nuclear Information System (INIS)

    Kusano, Shoichi

    1993-01-01

    Firstly, from an historic point of view, fundamental concepts on digital imaging were reviewed to provide a foundation for discussion of digital radiography. Secondly, this review summarized the results of ongoing research in computed radiography that replaces the conventional film-screen system with a photo-stimulable phosphor plate; and thirdly, image quality, radiation protection, and image processing techniques were discussed with emphasis on picture archiving and communication system environment as our final goal. Finally, future expansion of digital radiography was described based on the present utilization of computed tomography at the National Defense Medical College Hospital. (author) 60 refs

  18. Digital X-ray Imaging in Dentistry

    International Nuclear Information System (INIS)

    Kim, Eun Kyung

    1999-01-01

    In dentistry, Radio Visio Graphy was introduced as a first electronic dental x-ray imaging modality in 1989. Thereafter, many types of direct digital radiographic systems have been produced in the last decade. They are based either on charge-coupled device (CCD) or on storage phosphor technology. In addition, new types of digital radiographic system using amorphous selenium, image intensifier etc. are under development. Advantages of digital radiographic system are elimination of chemical processing, reduction in radiation dose, image processing, computer storage, electronic transfer of images and so on. Image processing includes image enhancement, image reconstruction, digital subtraction, etc. Especially digital subtraction and reconstruction can be applied in many aspects of clinical practice and research. Electronic transfer of images enables filmless dental hospital and teleradiology/teledentistry system. Since the first image management and communications system (IMACS) for dentomaxillofacial radiology was reported in 1992, IMACS in dental hospital has been increasing. Meanwhile, researches about computer-assisted diagnosis, such as structural analysis of bone trabecular patterns of mandible, feature extraction, automated identification of normal landmarks on cephalometric radiograph and automated image analysis for caries or periodontitis, have been performed actively in the last decade. Further developments in digital radiographic imaging modalities, image transmission system, imaging processing and automated analysis software will change the traditional clinical dental practice in the 21st century.

  19. Digital X-ray Imaging in Dentistry

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Dankook University, Yongin (Korea, Republic of)

    1999-08-15

    In dentistry, Radio Visio Graphy was introduced as a first electronic dental x-ray imaging modality in 1989. Thereafter, many types of direct digital radiographic systems have been produced in the last decade. They are based either on charge-coupled device (CCD) or on storage phosphor technology. In addition, new types of digital radiographic system using amorphous selenium, image intensifier etc. are under development. Advantages of digital radiographic system are elimination of chemical processing, reduction in radiation dose, image processing, computer storage, electronic transfer of images and so on. Image processing includes image enhancement, image reconstruction, digital subtraction, etc. Especially digital subtraction and reconstruction can be applied in many aspects of clinical practice and research. Electronic transfer of images enables filmless dental hospital and teleradiology/teledentistry system. Since the first image management and communications system (IMACS) for dentomaxillofacial radiology was reported in 1992, IMACS in dental hospital has been increasing. Meanwhile, researches about computer-assisted diagnosis, such as structural analysis of bone trabecular patterns of mandible, feature extraction, automated identification of normal landmarks on cephalometric radiograph and automated image analysis for caries or periodontitis, have been performed actively in the last decade. Further developments in digital radiographic imaging modalities, image transmission system, imaging processing and automated analysis software will change the traditional clinical dental practice in the 21st century.

  20. Novel heat–integrated and intensified biorefinery process for cellulosic ethanol production from lignocellulosic biomass

    International Nuclear Information System (INIS)

    Nhien, Le Cao; Long, Nguyen Van Duc; Lee, Moonyong

    2017-01-01

    Highlights: • A compact biorefinery design was proposed for cellulosic ethanol purification. • Actual fermentation broth from lignocellulosic biomass was considered. • Process integration and intensification achieves competitive biorefinery context. • The response surface method optimizes the complex column structure effectively. • The proposed process could save up to 47.6% of total annual cost. - Abstract: Biofuels have the most potential as an alternative to fossil fuels and overcoming global warming, which has become one of the most serious environmental issues over the past few decades. As the world confronts food shortages due to an increase in world population, the development of biofuels from inedible lignocellulosic feedstock may be more sustainable in the long term. Inspired by the NREL conventional process, this paper proposes a novel heat–integrated and intensified biorefinery design for cellulosic ethanol production from lignocellulosic biomass. For the preconcentration section, heat pump assisted distillation and double–effect heat integration were evaluated, while a combination of heat–integrated technique and intensified technique, extractive dividing wall column (EDWC), was applied to enhance the process energy and cost efficiency for the purification section. A biosolvent, glycerol, which can be produced from biodiesel production, was used as the extracting solvent in an EDWC to obtain a high degree of integration in a biorefinery context. All configuration alternatives were simulated rigorously using Aspen Plus were based on the energy requirements, total annual costs (TAC), and total carbon dioxide emissions (TCE). In addition, the structure of the EDWC was optimized using the reliable response surface method, which was carried out using Minitab statistical software. The simulation results showed that the proposed heat–integrated and intensified process can save up to 47.6% and 56.9% of the TAC and TCE for the purification

  1. Dispersal limitation drives successional pathways in Central Siberian forests under current and intensified fire regimes.

    Science.gov (United States)

    Tautenhahn, Susanne; Lichstein, Jeremy W; Jung, Martin; Kattge, Jens; Bohlman, Stephanie A; Heilmeier, Hermann; Prokushkin, Anatoly; Kahl, Anja; Wirth, Christian

    2016-06-01

    Fire is a primary driver of boreal forest dynamics. Intensifying fire regimes due to climate change may cause a shift in boreal forest composition toward reduced dominance of conifers and greater abundance of deciduous hardwoods, with potential biogeochemical and biophysical feedbacks to regional and global climate. This shift has already been observed in some North American boreal forests and has been attributed to changes in site conditions. However, it is unknown if the mechanisms controlling fire-induced changes in deciduous hardwood cover are similar among different boreal forests, which differ in the ecological traits of the dominant tree species. To better understand the consequences of intensifying fire regimes in boreal forests, we studied postfire regeneration in five burns in the Central Siberian dark taiga, a vast but poorly studied boreal region. We combined field measurements, dendrochronological analysis, and seed-source maps derived from high-resolution satellite images to quantify the importance of site conditions (e.g., organic layer depth) vs. seed availability in shaping postfire regeneration. We show that dispersal limitation of evergreen conifers was the main factor determining postfire regeneration composition and density. Site conditions had significant but weaker effects. We used information on postfire regeneration to develop a classification scheme for successional pathways, representing the dominance of deciduous hardwoods vs. evergreen conifers at different successional stages. We estimated the spatial distribution of different successional pathways under alternative fire regime scenarios. Under intensified fire regimes, dispersal limitation of evergreen conifers is predicted to become more severe, primarily due to reduced abundance of surviving seed sources within burned areas. Increased dispersal limitation of evergreen conifers, in turn, is predicted to increase the prevalence of successional pathways dominated by deciduous hardwoods

  2. Digital fabrication

    CERN Document Server

    2012-01-01

    The Winter 2012 (vol. 14 no. 3) issue of the Nexus Network Journal features seven original papers dedicated to the theme “Digital Fabrication”. Digital fabrication is changing architecture in fundamental ways in every phase, from concept to artifact. Projects growing out of research in digital fabrication are dependent on software that is entirely surface-oriented in its underlying mathematics. Decisions made during design, prototyping, fabrication and assembly rely on codes, scripts, parameters, operating systems and software, creating the need for teams with multidisciplinary expertise and different skills, from IT to architecture, design, material engineering, and mathematics, among others The papers grew out of a Lisbon symposium hosted by the ISCTE-Instituto Universitario de Lisboa entitled “Digital Fabrication – A State of the Art”. The issue is completed with four other research papers which address different mathematical instruments applied to architecture, including geometric tracing system...

  3. Digital Relationships

    DEFF Research Database (Denmark)

    Ledborg Hansen, Richard

    -­rich information and highly interesting communication are sky-­high and rising. With a continuous increase in digitized communication follows a decrease in face-­to-­face encounters and our ability to engage in inter-­personal relationships are suffering for it (Davis, 2013). The behavior described in this paper......-­‐Jones, 2011) for increases in effectiveness and efficiency we indiscriminately embrace digital communication and digitized information dissemination with enthusiasm – at the risk of ignoring the potentially dark side of technology. However, technology also holds a promise for better understanding precisely...... for the same reasons – that the growing amount of digitized communication “out there” represents data waiting to be sifted, analyzed and decoded. In this paper “Facebook behavior” refers to a particular behavior characterized by presenting your self and representations of selected self in the hope of getting...

  4. Digital Discretion

    DEFF Research Database (Denmark)

    Busch, Peter Andre; Zinner Henriksen, Helle

    2018-01-01

    discretion is suggested to reduce this footprint by influencing or replacing their discretionary practices using ICT. What is less researched is whether digital discretion can cause changes in public policy outcomes, and under what conditions such changes can occur. Using the concept of public service values......This study reviews 44 peer-reviewed articles on digital discretion published in the period from 1998 to January 2017. Street-level bureaucrats have traditionally had a wide ability to exercise discretion stirring debate since they can add their personal footprint on public policies. Digital......, we suggest that digital discretion can strengthen ethical and democratic values but weaken professional and relational values. Furthermore, we conclude that contextual factors such as considerations made by policy makers on the macro-level and the degree of professionalization of street...

  5. Intensified Multifactorial Intervention in Type 2 Diabetes and Microalbuminuria Reduces End Stage Renal Disease and Mortality

    DEFF Research Database (Denmark)

    Oellgaard, Jens; Gæde, Peter; Rossing, Peter

    2016-01-01

    -label trial. Duration of the intervention was 8 years, where after all patients were recommended intensified treatment. Total follow-up of up to 21 years of 24 hour urinary albumin excretion rate and GFR (51Cr-EDTA-clearance) assessed at 6 study visits. Information on end stage renal disease (ESRD......) and mortality was obtained from national registries. Outcome measures were progression to macroalbuminuria (>300 mg/24h), decline-rates of GFR and progression to end stage renal disease (ESRD) or death. Results: Progression to macroalbuminuria was reduced in the original intensive-therapy group with a hazard...

  6. A comparative study of CaWO4 and rare earth intensifying screens

    International Nuclear Information System (INIS)

    Ambiger, T.Y.; Ayappan, P.

    1978-01-01

    Three brands of commercially available calcium tungstate intensifying screens and a brand of rare earth screen emitting blue light have been used with two types of fast medical x-ray films, one imported and the other indigenous in various film-screen combinations and their sensitometric properties have been determined and compared. The rare earth screen has been found to be about 3 to 4 times faster than the tungstate screens without reduction in contrast. This indicates that the use of rare earth screen in medical radiography will help to reduce the patient dose by the same factor. (M.G.B.)

  7. Diels–Alder reactions of myrcene using intensified continuous-flow reactors

    Directory of Open Access Journals (Sweden)

    Christian H. Hornung

    2017-01-01

    Full Text Available This work describes the Diels–Alder reaction of the naturally occurring substituted butadiene, myrcene, with a range of different naturally occurring and synthetic dienophiles. The synthesis of the Diels–Alder adduct from myrcene and acrylic acid, containing surfactant properties, was scaled-up in a plate-type continuous-flow reactor with a volume of 105 mL to a throughput of 2.79 kg of the final product per day. This continuous-flow approach provides a facile alternative scale-up route to conventional batch processing, and it helps to intensify the synthesis protocol by applying higher reaction temperatures and shorter reaction times.

  8. Effects of Intensifying Labor Market Programs on Post-Unemployment Wages: Evidence From a Controlled Experiment

    DEFF Research Database (Denmark)

    Sørensen, Kenneth Lykke

    This paper investigates effects on wages of a Danish field experiment intensifying Active Labor Market Policies (ALMP).We link unemployed workers who participated in an ALMP experiment called “Quickly Back” carried out by the Danish Ministry of Employment 2005-2006 in two counties to matched...... employer-employee and public transfer register data up to 2008 enabling us to analyze exact labor market transitions and jobs of the participants. Men in one of the counties experienced significant higher probability of earning higher short and long term wages after treatment. Treated men in the other...

  9. Detection matrix of an electromagnetic radiation and radiological image intensifier comprising such a matrix

    International Nuclear Information System (INIS)

    Fraleux, Jean.

    1982-01-01

    This invention concerns a detection matrix comprising, in an electrode lattice of lines and columns, addressing means constituted of thin film technology MOS transistors and photoconductances which enable the number of unit module crossings to be halved and to bring about an increase in the effective detection area. This detection matrix is employed in radiological image intensifiers where it ensures the conversion of incident X photons into reading electric signals or only the detection of a visible radiation in the case where the incident X photons are converted into lesser energy photons by a scintillator. The scintillator is then formed of a panel brought into contact with the detector mosaic [fr

  10. Between Assessments, Digital Technologies and Big Data: The Growing Influence of "Hidden" Data Mediators in Education

    Science.gov (United States)

    Hartong, Sigrid

    2016-01-01

    The past few decades have witnessed a global enforcement of "governance by data" in education policy, including a significant increase of assessments and quantified evaluation. Within this context, this article focuses particularly on the intensifying evolvement of new (digital) information technologies and "mediated"…

  11. Digital Collections, Digital Libraries & the Digitization of Cultural Heritage Information.

    Science.gov (United States)

    Lynch, Clifford

    2002-01-01

    Discusses digital collections and digital libraries. Topics include broadband availability; digital rights protection; content, both non-profit and commercial; digitization of cultural content; sustainability; metadata harvesting protocol; infrastructure; authorship; linking multiple resources; data mining; digitization of reference works;…

  12. digital natives and digital immigrants

    OpenAIRE

    Cardina, Bruno; Francisco, Jerónimo; Reis, Pedro; trad. Silva, Fátima

    2011-01-01

    This article focuses on the generational gaps in school learning. Initially, we have tried to provide the framework in relation to the term digital native in order to understand the key aspects of the generation born after the advent and the global use of the Internet. They were found to be “multitasking” people, linked to technology and connectivity, as opposed to digital immigrants, born in an earlier period and seeking to adapt to the technological world. We also present some r...

  13. Design and analysis of a flux intensifying permanent magnet embedded salient pole wind generator

    Science.gov (United States)

    Guo, Yujing; Jin, Ping; Lin, Heyun; Yang, Hui; Lyu, Shukang

    2018-05-01

    This paper presents an improved flux intensifying permanent magnet embedded salient pole wind generator (FI-PMESPWG) with mirror symmetrical magnetizing directions permanent magnet (PM) for improving generator's performances. The air-gap flux densities, the output voltage, the cogging torque and the d- and q-axis inductances of FI-PMESPWG are all calculated and analyzed by using the finite element method (FEM). To highlight the advantages of the proposed FI-PMESPWG, an original permanent magnet embedded salient pole wind generator (PMESPWG) model is adopted for comparison under the same operating conditions. The calculating results show that the air-gap flux densities of FI-PMESPWG are intensified with the same magnet amounts because the PMs are set in a form of V shape in each pole. The difference between d-axis inductance and q-axis inductance of the proposed FI-PMESPWG is reduced. Thus, the output power of the proposed FI-PMESPWG reaches a higher value than that of the original PMESPWG at the same current phase angle. The cogging torque is diminished because the flux path is changed. All the analysis results indicate that the electromagnetic characteristics of the proposed FI-PMESPWG are significantly better than that of the original PMESPWG.

  14. Self-triggered image intensifier tube for high-resolution UHECR imaging detector

    CERN Document Server

    Sasaki, M; Jobashi, M

    2003-01-01

    The authors have developed a self-triggered image intensifier tube with high-resolution imaging capability. An image detected by a first image intensifier tube as an electrostatic lens with a photocathode diameter of 100 mm is separated by a half-mirror into a path for CCD readout (768x494 pixels) and a fast control to recognize and trigger the image. The proposed system provides both a high signal-to-noise ratio to improve single photoelectron detection and excellent spatial resolution between 207 and 240 mu m rendering this device a potentially essential tool for high-energy physics and astrophysics experiments, as well as high-speed photography. When combined with a 1-arcmin resolution optical system with 50 deg. field-of-view proposed by the present authors, the observation of ultra high-energy cosmic rays and high-energy neutrinos using this device is expected, leading to revolutionary progress in particle astrophysics as a complementary technique to traditional astronomical observations at multiple wave...

  15. Intensified Vegetation Water Use due to Soil Calcium Leaching under Acid Deposition

    Science.gov (United States)

    Lanning, M.; Wang, L.; Scanlon, T. M.; Vadeboncoeur, M. A.; Adams, M. B.; Epstein, H. E.; Druckenbrod, D.

    2017-12-01

    Despite the important role vegetation plays in the global water cycle, the exact controls of vegetation water use, especially the role of soil biogeochemistry, remain elusive. Nitrate and sulfate deposition from fossil fuel burning has caused significant soil acidification, leading to the leaching of soil base cations. From a physiological perspective, plants require various soil cations as signaling and regulatory ions as well as integral parts of structural molecules; a depletion of soil cations can cause reduced productivity and abnormal responses to environmental change. A deficiency in calcium could also potentially prolong stomatal opening, leading to increased transpiration until enough calcium had been acquired to stimulate stomatal closure. Based on the plant physiology and the nature of acidic deposition, we hypothesize that depletion of the soil calcium supply, induced by acid deposition, would intensify vegetation water use at the watershed scale. We tested this hypothesis by analyzing a long-term and unique data set (1989-2012) of soil lysimeter data along with stream flow and evapotranspiration data at the Fernow Experimental Forest. We show that depletion of soil calcium by acid deposition can intensify vegetation water use ( 10% increase in evapotranspiration and depletion in soil water) for the first time. These results are critical to understanding future water availability, biogeochemical cycles, and surficial energy flux and may help reduce uncertainties in terrestrial biosphere models.

  16. Design and test of a high resolution plastic scintillating fiber detector with intensified CCD readout

    International Nuclear Information System (INIS)

    Rebourgeard, P.

    1991-01-01

    We present the design of a particle detector involving a coherent array of 100 000 plastic scintillating microfibers, with an individual core diameter around 50 micrometers, and an intensified bidimensional CCD array. We investigate both theoretically and experimentally the use of polystyrene based scintillators in optical multimodal fibers. The isotropic excitation of modes and the characteristics of energy transfers between the polystyrene matrix and the added fluorescent dyes are of particular interest. An experimental approach is proposed and applied to the development of a new binary scintillator. In order to study the transmission of the signal from the interaction area to the output face, we specify the loss factors, the resolution and the signal to noise ratio within the fiber array. The low light level at the output face of the detector leads us to use image intensifiers in photon counting mode. This requires a detailed analysis of resolutions, gain, noise and detectivity concepts. We propose to describe these strongly correlated notions by the moment generation formalism. Thus, a previous modelisation of the photoelectronic devices allows us to evaluate the performance of the readout chain. A complete detector has been assembled and tested on a high energy hadron beam; the measurements are in good agreement with the modelisation [fr

  17. How do Rumination and Social Problem Solving Intensify Depression? A Longitudinal Study.

    Science.gov (United States)

    Hasegawa, Akira; Kunisato, Yoshihiko; Morimoto, Hiroshi; Nishimura, Haruki; Matsuda, Yuko

    2018-01-01

    In order to examine how rumination and social problem solving intensify depression, the present study investigated longitudinal associations among each dimension of rumination and social problem solving and evaluated aspects of these constructs that predicted subsequent depression. A three-wave longitudinal study, with an interval of 4 weeks between waves, was conducted. Japanese university students completed the Beck Depression Inventory-Second Edition, Ruminative Responses Scale, Social Problem-Solving Inventory-Revised Short Version, and Interpersonal Stress Event Scale on three occasions 4 weeks apart ( n  = 284 at Time 1, 198 at Time 2, 165 at Time 3). Linear mixed models were analyzed to test whether each variable predicted subsequent depression, rumination, and each dimension of social problem solving. Rumination and negative problem orientation demonstrated a mutually enhancing relationship. Because these two variables were not associated with interpersonal conflict during the subsequent 4 weeks, rumination and negative problem orientation appear to strengthen each other without environmental change. Rumination and impulsivity/carelessness style were associated with subsequent depressive symptoms, after controlling for the effect of initial depression. Because rumination and impulsivity/carelessness style were not concurrently and longitudinally associated with each other, rumination and impulsive/careless problem solving style appear to be independent processes that serve to intensify depression.

  18. Performance in sports--With specific emphasis on the effect of intensified training.

    Science.gov (United States)

    Bangsbo, J

    2015-12-01

    Performance in most sports is determined by the athlete's technical, tactical, physiological and psychological/social characteristics. In the present article, the physical aspect will be evaluated with a focus on what limits performance, and how training can be conducted to improve performance. Specifically how intensified training, i.e., increasing the amount of aerobic high-intensity and speed endurance training, affects physiological adaptations and performance of trained subjects. Periods of speed endurance training do improve performance in events lasting 30 s-4 min, and when combined with aerobic high-intensity sessions, also performance during longer events. Athletes in team sports involving intense exercise actions and endurance aspects, such as soccer and basketball, can also benefit from intensified training. Speed endurance training does reduce energy expenditure and increase expression of muscle Na(+), K(+) pump α subunits, which may preserve muscle cell excitability and delay fatigue development during intense exercise. When various types of training are conducted in the same period (concurrent training), as done in a number of sports, one type of training may blunt the effect of other types of training. It is not, however, clear how various training modalities are affecting each other, and this issue should be addressed in future studies. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. X-ray image intensifier tube and radiographic camera incorporating same

    International Nuclear Information System (INIS)

    1981-01-01

    An X-ray sensitive image intensifier tube is described. It has an input window comprising at least one of iron, chromium and nickel for receiving an X-ray image. There is a flat scintillator screen adjacent for converting the X-ray image into a light pattern image. Adjacent to this is a flat photocathode layer for emitting photoelectrons in a pattern corresponding to the light pattern image. Parallel to this and spaced from it is a flat phosphor display screen. Electrostatic voltage is applied to the display screen and the photocathode layer to create an electric field between them to accelerate the photoelectrons towards the display screen. The paths of such parallel straight trajectories are governed solely by the electrostatic voltage applied, the image at the display screen being substantially equal in size to that of the X-ray image received at the input window. The tube envelope is preferably metallic to enable the basic components to be kept at a neutral potential and avoid spurious emissions. A radiographic camera with such an intensifier tube is also described. (U.K.)

  20. X-ray topography with scintillators coupled to image intensifiers or camera tubes

    International Nuclear Information System (INIS)

    Beauvais, Yves; Mathiot, Alain.

    1978-01-01

    The possibility of imaging topographic figures in real time by using a thin scintillator coupled to either a high-gain image intensifier or a camera tube is investigated. The camera tube must have a high gain because of the low photon fluxes that are encountered in practice, and because of the relatively low quantum yield of thin phosphors. With conventional X-ray generators, the resolution is photon-noise limited. With more powerful generators like synchrotrons, real-time imaging appears possible, and the resolution is limited by the modulation transfer function of the image tube. Higher resolution can be reached by increasing the magnification between the screen and the image tube. When doing so, the input field is reduced and thinner phosphor screens must be used, resulting in a lower yield. Each time the magnification is doubled, the minimum required photon flux is multiplier by about 8, so that the advantages of increasing the magnification are rapidly limited, so far as real-time imaging is concerned. Because image tube resolution is mainly limited by the modulation transfer function of the phosphor for image intensifiers, and by that of the target for camera tubes, improvement of photocathode resolution can be obtained by magnifying electron optics. A zooming electron optic would permit the field and the resolution of the tube to be adapted to the observed subject. Unfortunately such tubes do not exist at present for this type of application, and in the required size

  1. Cheap streak camera based on the LD-S-10 intensifier tube

    Science.gov (United States)

    Dashevsky, Boris E.; Krutik, Mikhail I.; Surovegin, Alexander L.

    1992-01-01

    Basic properties of a new streak camera and its test results are reported. To intensify images on its screen, we employed modular G1 tubes, the LD-A-1.0 and LD-A-0.33, enabling magnification of 1.0 and 0.33, respectively. If necessary, the LD-A-0.33 tube may be substituted by any other image intensifier of the LDA series, the choice to be determined by the size of the CCD matrix with fiber-optical windows. The reported camera employs a 12.5- mm-long CCD strip consisting of 1024 pixels, each 12 X 500 micrometers in size. Registered radiation was imaged on a 5 X 0.04 mm slit diaphragm tightly connected with the LD-S- 10 fiber-optical input window. Electrons escaping the cathode are accelerated in a 5 kV electric field and focused onto a phosphor screen covering a fiber-optical plate as they travel between deflection plates. Sensitivity of the latter was 18 V/mm, which implies that the total deflecting voltage was 720 V per 40 mm of the screen surface, since reversed-polarity scan pulses +360 V and -360 V were applied across the deflection plate. The streak camera provides full scan times over the screen of 15, 30, 50, 100, 250, and 500 ns. Timing of the electrically or optically driven camera was done using a 10 ns step-controlled-delay (0 - 500 ns) circuit.

  2. Effects of optimization and image processing in digital chest radiography

    International Nuclear Information System (INIS)

    Kheddache, S.; Maansson, L.G.; Angelhed, J.E.; Denbratt, L.; Gottfridsson, B.; Schlossman, D.

    1991-01-01

    A digital system for chest radiography based on a large image intensifier was compared to a conventional film-screen system. The digital system was optimized with regard to spatial and contrast resolution and dose. The images were digitally processed for contrast and edge enhancement. A simulated pneumothorax and two and two simulated nodules were positioned over the lungs and the mediastinum of an anthro-pomorphic phantom. Observer performance was evaluated with Receiver Operating Characteristic (ROC) analysis. Five observers assessed the processed digital images and the conventional full-size radiographs. The time spent viewing the full-size radiographs and the digital images was recorded. For the simulated pneumothorax, the results showed perfect performance for the full-size radiographs and detectability was high also for the processed digital images. No significant differences in the detectability of the simulated nodules was seen between the two imaging systems. The results for the digital images showed a significantly improved detectability for the nodules in the mediastinum as compared to a previous ROC study where no optimization and image processing was available. No significant difference in detectability was seen between the former and the present ROC study for small nodules in the lung. No difference was seen in the time spent assessing the conventional full-size radiographs and the digital images. The study indicates that processed digital images produced by a large image intensifier are equal in image quality to conventional full-size radiographs for low-contrast objects such as nodules. (author). 38 refs.; 4 figs.; 1 tab

  3. Digital evidence

    Directory of Open Access Journals (Sweden)

    Lukić Tatjana

    2012-01-01

    Full Text Available Although computer makes human activities faster and easier, innovating and creating new forms of work and other kinds of activities, it also influenced the criminal activity. The development of information technology directly affects the development of computer forensics without which, it can not even imagine the discovering and proving the computer offences and apprehending the perpetrator. Information technology and computer forensic allows us to detect and prove the crimes committed by computer and capture the perpetrators. Computer forensics is a type of forensics which can be defined as a process of collecting, preserving, analyzing and presenting digital evidence in court proceedings. Bearing in mind, that combat against crime, in which computers appear as an asset or object of the offense, requires knowledge of digital evidence as well as specific rules and procedures, the author in this article specifically addresses the issues of digital evidence, forensic (computer investigation, specific rules and procedures for detecting, fixing and collecting digital evidence and use of this type of evidence in criminal proceedings. The author also delas with international standards regarding digital evidence and cyber-space investigation.

  4. Digital watermark

    Directory of Open Access Journals (Sweden)

    Jasna Maver

    2000-01-01

    Full Text Available The huge amount of multimedia contents available on the World-Wide-Web is beginning to raise the question of their protection. Digital watermarking is a technique which can serve various purposes, including intellectual property protection, authentication and integrity verification, as well as visible or invisible content labelling of multimedia content. Due to the diversity of digital watermarking applicability, there are many different techniques, which can be categorised according to different criteria. A digital watermark can be categorised as visible or invisible and as robust or fragile. In contrast to the visible watermark where a visible pattern or image is embedded into the original image, the invisible watermark does not change the visual appearance of the image. The existence of such a watermark can be determined only through a watermark ex¬traction or detection algorithm. The robust watermark is used for copyright protection, while the fragile watermark is designed for authentication and integrity verification of multimedia content. A watermark must be detectable or extractable to be useful. In some watermarking schemes, a watermark can be extracted in its exact form, in other cases, we can detect only whether a specific given watermarking signal is present in an image. Digital libraries, through which cultural institutions will make multimedia contents available, should support a wide range of service models for intellectual property protection, where digital watermarking may play an important role.

  5. Digital Creativity

    DEFF Research Database (Denmark)

    Petersson Brooks, Eva; Brooks, Anthony Lewis

    2014-01-01

    This paper reports on a study exploring the outcomes from children’s play with technology in early childhood learning practices. The paper addresses questions related to how digital technology can foster creativity in early childhood learning environments. It consists of an analysis of children......’s interaction with the KidSmart furniture focusing on digital creativity potentials and play values suggested by the technology. The study applied a qualitative approach and included125 children (aged three to five), 10 pedagogues, and two librarians. The results suggests that educators should sensitively...... consider intervening when children are interacting with technology, and rather put emphasize into the integration of the technology into the environment and to the curriculum in order to shape playful structures for children’s digital creativity....

  6. Digital radiography: description and user's guide

    International Nuclear Information System (INIS)

    Berthel, A.; Bonin, Th.; Cadilhon, S.; Thiery, Ch.; Chatellier, L.; Kaftandjian, V.; Honorat, Ph.; Torrent, J.; Le Brun, A.; Maglaive, J.C.; Moreau, Ph.; Pettier, J.L.; Rebuffel, V.; Roenelle, P.; Roussilhe, J.; Staat, St.; Tahon, M.

    2007-01-01

    The presented document arises from the work of the group 'Digital Radiography and sensors' of COFREND. It is a collective work of synthesis aimed to analyze the quality parameters of digital images influencing the answer and the diagnosis brought to a given industrial problem. Five families of digital sensors have been studied: 1. Image Intensifier coupled with CCD devices - 2. scintillators coupled with a CCD device- 3. Flat Panels with indirect conversion - 4. Flat Panels with direct electric conversion - 5. Photostimulable Storage Phosphor Screens). In particular, concerning a complete imaging chain, it deals with the notions of magnification, blur (unsharpness) (geometrical, kinetic or internal to the very sensor), noises, scattered radiation, spatial resolution, which is different from the one of analog detectors such as films, Contrast to Noise Ratio (CNR), sensitivity using IQIs, dynamic range, detection quantum efficiency, persistence and temporal resolution. This document is not a standard; it must be understood as a user's guide, and it approaches some essentials corrections to bring to a sensor in order to optimize his efficiency without losing information during the pre-processing phase in the radiographic acquisition. It also introduces some image processing tools commonly used. It can be used as a source document to the future elaboration of a standardisation document. It augurs not at all of the choice of a digital sensor with regard to the traditional radiographic film, but gives bases of reflection to a radio user for a sensible transfer from the classic radiography to the digital radiography. (authors)

  7. Digital photogrammetry

    CERN Document Server

    Egels, Yves

    2003-01-01

    Photogrammetry is the use of photography for surveying primarily and is used for the production of maps from aerial photographs. Along with remote sensing, it represents the primary means of generating data for Geographic Information Systems (GIS). As technology develops, it is becoming easier to gain access to it. The cost of digital photogrammetric workstations are falling quickly and these new tools are therefore becoming accessible to more and more users. Digital Photogrammetry is particularly useful as a text for graduate students in geomantic and is also suitable for people with a good basic scientific knowledge who need to understand photogrammetry, and who wish to use the book as a reference.

  8. Digital Marketing

    OpenAIRE

    Jerry Wind; Vijay Mahajan

    2002-01-01

    The digital revolution has shaken marketing to its core with consumers being offered greater price transparency and often even the chance to dictate the price. What does pricing mean in a world in which customers propose their own prices (as at priceline.com) or buyers and sellers haggle independently in auctions (as at e-Bay)? The most significant changes in the digital marketing show the emergence of 'cyber consumers', the cyber business-to-business world and the changing reality of an incr...

  9. Digital "X"

    DEFF Research Database (Denmark)

    Baiyere, Abayomi; Grover, Varun; Gupta, Alok

    2017-01-01

    Interest in using digital before existing research concepts seem to be on the rise in the IS field. This panel is positioned to explore what value lies in labelling our research as digital “x” as opposed to the well established IT “x” (where “x” can be strategy, infrastructure, innovation, artifa...... between this stream of research and existing research. Central among the expected output of the panel is the advancement of suggestions for future research and the critical pitfalls to avoid in doing so....

  10. Digital Radiography

    Science.gov (United States)

    1986-01-01

    System One, a digital radiography system, incorporates a reusable image medium (RIM) which retains an image. No film is needed; the RIM is read with a laser scanner, and the information is used to produce a digital image on an image processor. The image is stored on an optical disc. System allows the radiologist to "dial away" unwanted images to compare views on three screens. It is compatible with existing equipment and cost efficient. It was commercialized by a Stanford researcher from energy selective technology developed under a NASA grant.

  11. Digital filters

    CERN Document Server

    Hamming, Richard W

    1997-01-01

    Digital signals occur in an increasing number of applications: in telephone communications; in radio, television, and stereo sound systems; and in spacecraft transmissions, to name just a few. This introductory text examines digital filtering, the processes of smoothing, predicting, differentiating, integrating, and separating signals, as well as the removal of noise from a signal. The processes bear particular relevance to computer applications, one of the focuses of this book.Readers will find Hamming's analysis accessible and engaging, in recognition of the fact that many people with the s

  12. Digital voltmeter

    International Nuclear Information System (INIS)

    Yohannes Kamadi; Soekarno.

    1976-01-01

    The electrical voltage measuring equipment with digital display has been made. This equipment uses four digits display with single polarity measurement and integrating system. Pulses from the oscillator will be counted and converted to the staircase voltages, and compared to the voltage measured. When the balance is already achieved, the pulse will appear at the comparator circuit. This pulse will be used to trigger univibrator circuit. The univibrator output is used as signal for stopping the counting, and when reading time T already stops, the counting system will be reset. (authors)

  13. Digital communication

    CERN Document Server

    Das, Apurba

    2010-01-01

    ""Digital Communications"" presents the theory and application of the philosophy of Digital Communication systems in a unique but lucid form. This book inserts equal importance to the theory and application aspect of the subject whereby the authors selected a wide class of problems. The Salient features of the book are: the foundation of Fourier series, Transform and wavelets are introduces in a unique way but in lucid language; the application area is rich and resemblance to the present trend of research, as we are attached with those areas professionally; a CD is included which contains code

  14. Digital literacies

    CERN Document Server

    Hockly, Nicky; Pegrum, Mark

    2014-01-01

    Dramatic shifts in our communication landscape have made it crucial for language teaching to go beyond print literacy and encompass the digital literacies which are increasingly central to learners' personal, social, educational and professional lives. By situating these digital literacies within a clear theoretical framework, this book provides educators and students alike with not just the background for a deeper understanding of these key 21st-century skills, but also the rationale for integrating these skills into classroom practice. This is the first methodology book to address not jus

  15. Digital delicacies

    OpenAIRE

    Holley, Rose

    2001-01-01

    This presentation outlines the purpose and work of the newly appointed Digital Projects Librarian at the University of Auckland. It gives a brief overview of what digitisation is, the benefits, the stages of a digitisation project and also samples of interesting international digitisation projects and new University of Auckland Library Digitisation projects.

  16. Digital Forensics

    Science.gov (United States)

    Harron, Jason; Langdon, John; Gonzalez, Jennifer; Cater, Scott

    2017-01-01

    The term forensic science may evoke thoughts of blood-spatter analysis, DNA testing, and identifying molds, spores, and larvae. A growing part of this field, however, is that of digital forensics, involving techniques with clear connections to math and physics. This article describes a five-part project involving smartphones and the investigation…

  17. Digital Disruption

    DEFF Research Database (Denmark)

    Rosenstand, Claus Andreas Foss

    det digitale domæne ud over det niveau, der kendetegner den nuværende debat, så præsenteres der ny viden om digital disruption. Som noget nyt udlægges Clayton Christens teori om disruptiv innovation med et særligt fokus på små organisationers mulighed for eksponentiel vækst. Specielt udfoldes...... forholdet mellem disruption og den stadig accelererende digitale udvikling i konturerne til ny teoridannelse om digital disruption. Bogens undertitel ”faretruende og fascinerende forandringer” peger på, at der er behov for en nuanceret debat om digital disruption i modsætning til den tone, der er slået an i...... videre kalder et ”disruption-råd”. Faktisk er rådet skrevet ind i 2016 regeringsgrundlaget for VLK-regeringen. Disruption af organisationer er ikke et nyt fænomen; men hastigheden, hvormed det sker, er stadig accelererende. Årsagen er den globale mega-trend: Digitalisering. Og derfor er specielt digital...

  18. Digital books.

    Science.gov (United States)

    Wink, Diane M

    2011-01-01

    In this bimonthly series, the author examines how nurse educators can use the Internet and Web-based computer technologies such as search, communication, and collaborative writing tools; social networking and social bookmarking sites; virtual worlds; and Web-based teaching and learning programs. This article describes digital books.

  19. Digital forvaltning

    DEFF Research Database (Denmark)

    Remmen, Arne; Larsen, Torben; Mosgaard, Mette

    2004-01-01

    Større effektivitet, bedre service og mere demokrai er blot nogle af forventningerne til indførelse af digital forveltning i kommunerne. Kapitlet giver bland andet svar på spørgsmålene : Hvordan lever kommunerne op hertil i dagligdagen? hvilke virkemidler anvender de? Hvilke barrierer har der været...

  20. Digital Methods

    NARCIS (Netherlands)

    Rogers, R.

    2013-01-01

    In Digital Methods, Richard Rogers proposes a methodological outlook for social and cultural scholarly research on the Web that seeks to move Internet research beyond the study of online culture. It is not a toolkit for Internet research, or operating instructions for a software package; it deals

  1. Large-image intensifier photofluorography and conventional radiography in pulmonary emphysema

    International Nuclear Information System (INIS)

    Manninen, H.; Partanen, K.; Soimakallio, S.; Rytkoenen, H.

    1988-01-01

    Large-screen image intensifier (II) photofluorography was compared with full-size screen-film chest radiography in the diagnosis of pulmonary emphysema in 84 patients. Photospot films and conventional radiographs were interpreted independently by three radiologists. Computed tomography (CT) was used as an independent reference technique, and diagnostic performance of chest radiography in various CT patterns of emphysema was evaluated. The difference in diagnostic sensitivity for emphysema in favor of conventional chest radiography over photofluorography (0.65 versus 0.56) was statistically significant (p < 0.05). Specificity of the imaging modalities was equal: 0.78 in full-size films and 0.77 in photospot films. All CT patterns of emphysema had great false negative response rates in chest radiography, which is an inaccurate technique for the diagnosis of emphysema. CT is required for reliable radiologic evaluation of emphysema. (orig.)

  2. Radial-pulse propagation and impedance characteristics of optically shuttered channel intensifier tubes

    International Nuclear Information System (INIS)

    Detch, J.L. Jr.; Noel, B.W.

    1981-01-01

    Electrically gated proximity-focused channel intensifier tubes are often used as optical shutters. Optimum nanosecond shuttering requires both understanding the electrical pulse propagation across the device structure and proper impedance matching. A distributed-transmission-line model is developed that describes analytically the voltage- and current-wave propagation characteristics as functions of time for any point on the surface. The optical gain's spatial uniformity and shutter-open times are shown to depend on the electrical pulse width and amplitude, and on the applied bias. The driving-point impedance is derived from the model and is expressed as a function of an infinite sum of terms in the complex frequency. The synthesis in terms of lumped-constant network elements is realized in first- and second-Foster equivalent circuits. Experimental impedance data are compared with the model's predictions and deviations from the ideal model are discussed

  3. Nanoparticles generated by laser in liquids as contrast medium and radiotherapy intensifiers

    Science.gov (United States)

    Restuccia, Nancy; Torrisi, Lorenzo

    2018-01-01

    The synthesis of Au and Ag nanoparticles (NP) though laser ablation in liquids as a function the laser parameters is presented. Spherical NPs with diameter distribution within 1 and 100 nm were prepared by laser ablation in water. The nanoparticles characterization was performed using optical spectroscopy and electronic microscopy (SEM and TEM) measurements. Studies of the possible use of metallic nanoparticles as intensifier of diagnostics imaging contrast medium and absorbing dose from ionizing radiations in traditional radiotherapy and protontherapy are presented. Examples of in vitro (in tissue equivalent materials) and in vivo (in mice), were conducted thank to simulation programs permitting to evaluate the enhancement of efficiency in imaging and therapy as a function of the NPs concentrations and irradiation conditions.

  4. Nanoparticles generated by laser in liquids as contrast medium and radiotherapy intensifiers

    Directory of Open Access Journals (Sweden)

    Restuccia Nancy

    2018-01-01

    Full Text Available The synthesis of Au and Ag nanoparticles (NP though laser ablation in liquids as a function the laser parameters is presented. Spherical NPs with diameter distribution within 1 and 100 nm were prepared by laser ablation in water. The nanoparticles characterization was performed using optical spectroscopy and electronic microscopy (SEM and TEM measurements. Studies of the possible use of metallic nanoparticles as intensifier of diagnostics imaging contrast medium and absorbing dose from ionizing radiations in traditional radiotherapy and protontherapy are presented. Examples of in vitro (in tissue equivalent materials and in vivo (in mice, were conducted thank to simulation programs permitting to evaluate the enhancement of efficiency in imaging and therapy as a function of the NPs concentrations and irradiation conditions.

  5. Lead foil in dental X-ray film: Backscattering rejection or image intensifier?

    International Nuclear Information System (INIS)

    Hönnicke, M.G.; Delben, G.J.; Godoi, W.C.; Swinka-Filho, V.

    2014-01-01

    Dental X-ray films are still largely used due to sterilization issues, simplicity and, mainly, economic reasons. These films almost always are double coated (double emulsion) and have a lead foil in contact with the film for X-ray backscattering rejection. Herein we explore the use of the lead foil as an image intensifier. In these studies, spatial resolution was investigated when images were acquired on the dental X-ray films with and without the lead foil. Also, the lead foil was subjected to atomic analysis (fluorescent measurements) and structure analysis (X-ray diffraction). We determined that the use of the lead foil reduces the exposure time, however, does not affect the spatial resolution on the acquired images. This suggests that the fluorescent radiation spread is smaller than the grain sizes of the dental X-ray films

  6. Lead foil in dental X-ray film: Backscattering rejection or image intensifier?

    Science.gov (United States)

    Hönnicke, M. G.; Delben, G. J.; Godoi, W. C.; Swinka-Filho, V.

    2014-11-01

    Dental X-ray films are still largely used due to sterilization issues, simplicity and, mainly, economic reasons. These films almost always are double coated (double emulsion) and have a lead foil in contact with the film for X-ray backscattering rejection. Herein we explore the use of the lead foil as an image intensifier. In these studies, spatial resolution was investigated when images were acquired on the dental X-ray films with and without the lead foil. Also, the lead foil was subjected to atomic analysis (fluorescent measurements) and structure analysis (X-ray diffraction). We determined that the use of the lead foil reduces the exposure time, however, does not affect the spatial resolution on the acquired images. This suggests that the fluorescent radiation spread is smaller than the grain sizes of the dental X-ray films.

  7. Stepping back to advance: Why IGD needs an intensified debate instead of a consensus.

    Science.gov (United States)

    Quandt, Thorsten

    2017-06-01

    Based on their analysis of Internet gaming disorder (IGD) criteria, Kuss, Griffiths, and Pontes (2017) come to the conclusion that the current situation can be described as "chaos and confusion." Their assessment is not an exaggeration. It can be argued that there are even more issues, on logical/definitional and political/social levels: (a) the IGD diagnosis is lacking a well-defined object, (b) the cause and effect cannot be differentiated outside lab conditions, (c) the social and political effects of declaring a social behavior as a disease are worrying, and (d) a rushed diagnosis may construct an addiction with potentially harmful effects on (formerly) healthy populations. Instead of closing the debate by declaring a consensus and codifying IGD in the DSM, an undogmatic, intensified, and broader discussion is needed.

  8. Are the Satellite-Observed Narrow, Streaky Chlorophyll Filaments Locally Intensified by the Submesoscale Processes?

    Science.gov (United States)

    2015-11-05

    HIS I’OR’A CANCELS AND SUPERSEOFS Al l PRFV•OUS VERSIONS ARE THE SATELLITE-OBSERVED NARROW, STREAKY CHLOROPHYLL FILAMENTS LOCALLY INTENSIFIED BY...AUGUST 2003 cold, dense jeto C 17 16 15 14 13 122.4W 122W 122.4W 122W warm, anticyclonic eddy CHLOROPHYLL 122.4W 122W 122.4W 122W 122.4W 122W filament...122.4W 122W mg/m 3 10 4 2 1 0.4 0.2 Figure 1. MODIS-Aqua SST and Chlorophyll a images for August 2003. Black lines on MODIS SST and Chlorophyll a

  9. Correlated observations of intensified whistler waves and electron acceleration around the geostationary orbit

    International Nuclear Information System (INIS)

    Xiao Fuliang; He Zhaoguo; Tang Lijun; Zong Qiugang; Wang Chengrui; Su Zhenpeng

    2012-01-01

    We report correlated observations of enhanced whistler waves and energetic electron acceleration collected by multiple satellites specifically near the geostationary orbit during the 7–10 November 2004 superstorms, together with multi-site observations of ULF wave power measured on the ground. Energetic (>0.6 MeV) electron fluxes are found to increase significantly during the recovery phase, reaching a peak value by ∼100 higher than the prestorm level. In particular, such high electron flux corresponds to intensified whistler wave activities but to the weak ULF wave power. This result suggests that wave–particle interaction appears to be more important than inward radial diffusion in acceleration of outer radiation belt energetic electrons in this event, assisting to better understand the acceleration mechanism. (paper)

  10. Has the Competition among Professions in the Nordic Welfare States Intensified? A Danish Case

    Directory of Open Access Journals (Sweden)

    John Storm Pedersen

    2014-06-01

    Full Text Available Has the competition among professions in the Nordic welfare states intensified in recent decades? Yes, and in a manner that has resulted in predictable classic struggles and conflicts among professions. We argue that the struggles and conflicts that arise translate into insufficient provision of welfare services for taxpayers’ money. To avoid this predicament, further developing co-operation among professions is important. Public managers, as argued in this article using a Danish case, play a significant role in achieving this. The Danish case studied shows how some public managers, in their efforts to create co-operation among professions, have developed a modern, dialogue-based management technique built on dialectical refutation, similar to Socratic elenchus.

  11. Matrix based method for synthesis of main intensified and integrated distillation sequences

    International Nuclear Information System (INIS)

    Khalili-Garakani, Amirhossein; Kasiri, Norollah; Ivakpour, Javad

    2016-01-01

    The objective of many studies in this area has involved access to a column-sequencing algorithm enabling designers and researchers alike to generate a wide range of sequences in a broad search space, and be as mathematically and as automated as possible for programing purposes and with good generality. In the present work an algorithm previously developed by the authors, called the matrix method, has been developed much further. The new version of the algorithm includes thermally coupled, thermodynamically equivalent, intensified, simultaneous heat and mass integrated and divided-wall column sequences which are of gross application and provide vast saving potential both on capital investment, operating costs and energy usage in industrial applications. To demonstrate the much wider searchable space now accessible, a three component separation has been thoroughly examined as a case study, always resulting in an integrated sequence being proposed as the optimum.

  12. A model-based framework for design of intensified enzyme-based processes

    DEFF Research Database (Denmark)

    Román-Martinez, Alicia

    This thesis presents a generic and systematic model-based framework to design intensified enzyme-based processes. The development of the presented methodology was motivated by the needs of the bio-based industry for a more systematic approach to achieve intensification in its production plants...... in enzyme-based processes which have found significant application in the pharmaceutical, food, and renewable fuels sector. The framework uses model-based strategies for (bio)-chemical process design and optimization, including the use of a superstructure to generate all potential reaction......(s)-separation(s) options according to a desired performance criteria and a generic mathematical model represented by the superstructure to derive the specific models corresponding to a specific process option. In principle, three methods of intensification of bioprocess are considered in this thesis: 1. enzymatic one...

  13. [New intensifying screens in clinical radiology. II. Examinations in clinical practice].

    Science.gov (United States)

    Freyschmidt, J; Saure, D; Hagemann, G

    1976-09-01

    A clinically applicable procedure for testing new intensifying rare earth screens, as well as the special Siemens' screen is described. The results are related to universal screens. The film-screen combination alpha 4XD (gadolinium oxysulphide with normal, green sensitive film) results in a reduction of radiation dose to half with detail comparable with universal screens. The Siemens' special screen has similar advantages. Screens with a higher intensification factor and reduction of the mAs to one sixth results in loss of detail. This does not necessarily reduce their clinical use if they are used for appropriate purposes. The results of this clinically orientated technique agreed well with physically objective methods using lead grids. The advantages of the new screens are discussed in terms of their practical application.

  14. Performance in sports - with specific emphasis on the effect of intensified training

    DEFF Research Database (Denmark)

    Bangsbo, Jens

    2015-01-01

    Performance in most sports is determined by the athlete's technical, tactical, physiological and psychological/social characteristics. In the present article, the physical aspect will be evaluated with a focus on what limits performance, and how training can be conducted to improve performance...... with aerobic high-intensity sessions, also performance during longer events. Athletes in team sports involving intense exercise actions and endurance aspects, such as soccer and basketball, can also benefit from intensified training. Speed endurance training does reduce energy expenditure and increase...... expression of muscle Na(+) , K(+) pump α subunits, which may preserve muscle cell excitability and delay fatigue development during intense exercise. When various types of training are conducted in the same period (concurrent training), as done in a number of sports, one type of training may blunt the effect...

  15. Influence of veiling glare in the image intensifier on cinefluorographic sensitometry

    International Nuclear Information System (INIS)

    Matsuda, Eiji; Sanada, Taizo; Hitomi, Go; Ishii, Koushi; Yoshida, Akira

    1998-01-01

    We have experienced variations in the shape of the cinesensitometric curve when the exposure field is greatly altered. The veiling glare that arises from the scattering of x-ray photons, electrons, and light in the x-ray image intensifier (X-I.I.) depends on the size of the exposure field. Also, the effect of adjacent chemicals that occurs during the development process depends on the size of the exposed area on film. The veiling glare in the X-I.I. and the adjacent chemical effect on cine film processing may be responsible for these phenomena. This study investigated the influences of veiling glare on the shape of the cinesensitometric curve. Results showed that the veiling glare of the X-I.I. acts to increase the sensitivity of the cinesensitometric curve on the X-I.I. when the exposed area on the X-I.I. is larger. (author)

  16. Influence of veiling glare in the image intensifier on cinefluorographic sensitometry

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Eiji; Sanada, Taizo; Hitomi, Go; Ishii, Koushi [Kawasaki Medical School, Kurashiki, Okayama (Japan). Hospital; Yoshida, Akira

    1998-08-01

    We have experienced variations in the shape of the cinesensitometric curve when the exposure field is greatly altered. The veiling glare that arises from the scattering of x-ray photons, electrons, and light in the x-ray image intensifier (X-I.I.) depends on the size of the exposure field. Also, the effect of adjacent chemicals that occurs during the development process depends on the size of the exposed area on film. The veiling glare in the X-I.I. and the adjacent chemical effect on cine film processing may be responsible for these phenomena. This study investigated the influences of veiling glare on the shape of the cinesensitometric curve. Results showed that the veiling glare of the X-I.I. acts to increase the sensitivity of the cinesensitometric curve on the X-I.I. when the exposed area on the X-I.I. is larger. (author)

  17. The visible intensified cameras for plasma imaging in the TJ-II stellarator

    International Nuclear Information System (INIS)

    Cal, E. de la; Carralero, D.; Pablos, J.L. de; Alonso, A.; Rios, L.; Garcia Sanchez, P.; Hidalgo, C.

    2011-01-01

    Visible cameras are widely used in fusion experiments for diagnosis and for machine safety issues. They are generally used to monitor the plasma emission, but are also sensible to surface Blackbody radiation and Bremsstrahlung. Fast or high speed cameras capable of operating in the 10 5 frames per second speed range are today commercially available and offer the opportunity to plasma fusion researchers of two-dimensional (2D) imaging of fast phenomena such as turbulence, ELMs, disruptions, dust, etc. The tracking of these fast phenomena requires short exposure times down to the μ s range and the light intensity can be often near the signal to noise ratio limit especially in low plasma emission regions such as the far SOL Additionally, when using interference filters to monitor, e.g. impurity line emission, the photon flux is strongly reduced and the emission cannot be imaged at high speed. Therefore, the use of image intensifiers that amplify the light intensity onto the camera sensor can be of great help. The present work describes the use of intensifiers in the visible fast cameras of TJ-II stellarator. We have achieved spectroscopic plasma imaging of filtered impurity atomic line emission at short exposure times down to the 10 μ s range depending on atomic line and concentration. Additionally, plasma movies at velocities of 2x10 5 frames per second near the camera operation limit can be recorded with exposure times well below 1 μ s with sufficient signal to noise ratio. Although an increasing degradation of the image quality appears when raising the light amplification, an effective gain of up to two orders of magnitude of the light intensity is feasible for many applications (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  18. The visible intensified cameras for plasma imaging in the TJ-II stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Cal, E. de la; Carralero, D.; Pablos, J.L. de; Alonso, A.; Rios, L.; Garcia Sanchez, P.; Hidalgo, C. (Laboratorio Nacional de Fusion, Asociacion Euratom-Ciemat, Av. Complutense 22, E-28040 Madrid)

    2011-09-15

    Visible cameras are widely used in fusion experiments for diagnosis and for machine safety issues. They are generally used to monitor the plasma emission, but are also sensible to surface Blackbody radiation and Bremsstrahlung. Fast or high speed cameras capable of operating in the 10{sup 5} frames per second speed range are today commercially available and offer the opportunity to plasma fusion researchers of two-dimensional (2D) imaging of fast phenomena such as turbulence, ELMs, disruptions, dust, etc. The tracking of these fast phenomena requires short exposure times down to the {mu} s range and the light intensity can be often near the signal to noise ratio limit especially in low plasma emission regions such as the far SOL Additionally, when using interference filters to monitor, e.g. impurity line emission, the photon flux is strongly reduced and the emission cannot be imaged at high speed. Therefore, the use of image intensifiers that amplify the light intensity onto the camera sensor can be of great help. The present work describes the use of intensifiers in the visible fast cameras of TJ-II stellarator. We have achieved spectroscopic plasma imaging of filtered impurity atomic line emission at short exposure times down to the 10 {mu} s range depending on atomic line and concentration. Additionally, plasma movies at velocities of 2x10{sup 5} frames per second near the camera operation limit can be recorded with exposure times well below 1 {mu} s with sufficient signal to noise ratio. Although an increasing degradation of the image quality appears when raising the light amplification, an effective gain of up to two orders of magnitude of the light intensity is feasible for many applications (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  19. Reduced risk of heart failure with intensified multifactorial intervention in individuals with type 2 diabetes and microalbuminuria

    DEFF Research Database (Denmark)

    Oellgaard, Jens; Gæde, Peter; Rossing, Peter

    2018-01-01

    of hospitalisation for heart failure. METHODS: One hundred and sixty individuals were randomised to conventional or intensified multifactorial intervention, using sealed envelopes. The trial was conducted using the Prospective, Randomised, Open, Blinded Endpoints (PROBE) design. After 7.8 years, all individuals were......AIMS/HYPOTHESIS: In type 2 diabetes mellitus, heart failure is a frequent, potentially fatal and often forgotten complication. Glucose-lowering agents and adjuvant therapies modify the risk of heart failure. We recently reported that 7.8 years of intensified compared with conventional...... offered intensified therapy and the study continued as an observational follow-up study for an additional 13.4 years. Heart-failure hospitalisations were adjudicated from patient records by an external expert committee blinded for treatment allocation. Event rates were compared using a Cox regression...

  20. SIgA response and incidence of upper respiratory tract infections during intensified training in youth basketball players.

    Science.gov (United States)

    Moraes, H; Aoki, M S; Freitas, C G; Arruda, Afs; Drago, G; Moreira, A

    2017-03-01

    The aim of the present study was to examine the effect of an intensified training phase followed by a tapering phase on the salivary immunoglobulin A concentration and on the upper respiratory tract infection (URTI) symptoms in young male basketball players. The session rating of perceived exertion method was used to quantify the internal training load, and the Wisconsin Upper Respiratory Symptom Survey-21 questionnaire was used to assess URTI symptoms. The Yo-Yo IR1 test and saliva collection were carried out at the beginning of the study (T1), after the intensified phase (T2), and after tapering (T3). A higher internal training load was observed for the intensified phase compared with the tapering phase (t=19.10; ptraining load followed by a tapering period negatively affects the mucosal immune function with no significant change in severity of URTI in young basketball players.

  1. Possibilities of reducing radiation doses in spinograms of adolescents by means of most intensifying screens and compensating screens

    Energy Technology Data Exchange (ETDEWEB)

    Pollaehne, W; Brandt, G A [Staedtisches Klinikum Berlin-Buch (German Democratic Republic)

    1980-01-01

    Most intensifying screens based on CaWO/sub 4/ and LaOBr/sub 2/ or combinations of them were used in radiography of both the thoracic and the lumbar parts of the spines of adolescents. The results obtained were compared with those achieved by means of screens usually used for spinograms. Radiation exposure was reduced, on an average by 30-40%, when most intensifying screens were used, the image quality being the same. The introduction of high-speed superscreens is pressingly recommended.

  2. Digital Humanities and networked digital media

    DEFF Research Database (Denmark)

    Finnemann, Niels Ole

    2014-01-01

    This article discusses digital humanities and the growing diversity of digital media, digital materials and digital methods. The first section describes the humanities computing tradition formed around the interpretation of computation as a rule-based process connected to a concept of digital...... materials centred on the digitisation of non-digital, finite works, corpora and oeuvres. The second section discusses “the big tent” of contemporary digital humanities. It is argued that there can be no unifying interpretation of digital humanities above the level of studying digital materials with the help...... of software-supported methods. This is so, in part, because of the complexity of the world and, in part, because digital media remain open to the projection of new epistemologies onto the functional architecture of these media. The third section discusses the heterogeneous character of digital materials...

  3. Digital Materia

    OpenAIRE

    Lindgren, Marcus; Richey, Emma

    2014-01-01

    Med tankar från pedagogen Montessori och filosoferna Platon och Baudrillard har detta arbete behandlat frågor om datorn och dess betydelse för en grafiker. Frågeställningen formulerades efter hand och lydde tillslut: ”Hur kan materia te sig i digital form?” Forskningen resulterade i en hypotes för hur digital materia skulle födas i datorn: genom att blanda två uppsättningar av data, såsom två genuppsättningar tillsammans skapar en ny organism. Under produktionen utvecklades därmed en metod fö...

  4. Becoming digital

    DEFF Research Database (Denmark)

    Pors, Anja Svejgaard

    2015-01-01

    government, and draws on empirical material generated through observations, field notes, interviews and policy documents. The material is documenting how service is performed by frontline agents in the ‘bureaucratic encounter’ with citizens, who needs assistance to use digital self-service in order to apply...... online for a public benefit. Findings: The paper shows that e-government technology changes the mode of professionalism in citizen service from service to support. The paper gives an empirical account of recent Danish digital reforms and shows how the reforms both enable and constrain the work...... of ‘becoming digital’ by frontline agents. Overall the street-level bureaucrat’s classical tasks such as specialized casework are being displaced into promoting and educational tasks. An implication of this is blurred distinctions between professional skills and personal competences of the frontline agent...

  5. Digital resources

    Directory of Open Access Journals (Sweden)

    Redazione Reti Medievali (a cura di

    2005-12-01

    Full Text Available Bibliotheca Latinitatis Mediaevalis (circa VII sec. - XIV sec. IntraText Digital Library [01/06] Corpus Scriptorum Latinorum. A digital library of Latin literature by David Camden [01/06] Fonti disponibili online concernenti la vita religiosa medievale Rete Vitae Religiosae Mediaevalis Studia Conectens [01/06] Fuentes del Medievo Hispanico Instituto de Historia, Consejo Superior de Investigaciones Científicas [01/06] Latin Literature Forum Romanum [01/06] Ludovico Antonio Muratori, Dissertazioni sopra le antichità italiane, 1751 Biblioteca dei Classici Italiani di Giuseppe Bonghi [01/06] Medieval Latin The Latin Library [01/06] Médiévales Presses Universitaires de Vincennes - Revues.org [01/06] Regesta imperii Deutsche Kommission für die Bearbeitung der Regesta Imperii e.V. [01/06] Suda On Line Byzantine Lexicography [01/06

  6. Digital teenagers

    Directory of Open Access Journals (Sweden)

    Rafael Conde Melguizo

    2011-12-01

    Full Text Available Espín, Manuel (Coord.(2011 Adolescentes Digitales.  Revista Estudios de Juventud, Nº 92. Marzo 2011. INJUVE, Madrid."Adolescentes digitales" se nos muestra como una obra que pretende explorar desde distintos puntos de vista la realidad de la generación conocida como “nativos digitales” (Prensky, la generación actual de adolescentes que ha crecido con internet y el mundo digital como su entorno normal de socialización.

  7. Digital Flora

    OpenAIRE

    Bunnell, Katie

    2007-01-01

    This research is concerned with developing a new business model for flexible small scale ceramic production that exploits the customisation capabilities of digital manufacturing technologies and the market potential and global connectivity of the world wide web. It is arguably of particular relevance to regional economic development in remote areas (Amin, Tomaney, Sabel) such as Cornwall where there is a culture of high quality small scale production, limited market and manufacturing opportun...

  8. A technique of scatter and glare correction for videodensitometric studies in digital subtraction videoangiography

    International Nuclear Information System (INIS)

    Shaw, C.G.; Ergun, D.L.; Myerowitz, P.D.; Van Lysel, M.S.; Mistretta, C.A.; Zarnstorff, W.C.; Crummy, A.B.

    1982-01-01

    The logarithmic amplification of video signals and the availability of data in digital form make digital subtraction videoangiography a suitable tool for videodensitometric estimation of physiological quantities. A system for this purpose was implemented with a digital video image processor. However, it was found that the radiation scattering and veiling glare present in the image-intensified video must be removed to make meaningful quantitations. An algorithm to make such a correction was developed and is presented. With this correction, the videodensitometry system was calibrated with phantoms and used to measure the left ventricular ejection fraction of a canine heart

  9. Digital citizens Digital nations: the next agenda

    NARCIS (Netherlands)

    A.W. (Bert) Mulder; M.W. (Martijn) Hartog

    2015-01-01

    DIGITAL CITIZENS CREATE A DIGITAL NATION Citizens will play the lead role as they – in the next phase of the information society – collectively create a digital nation. Personal adoption of information and communication technology will create a digital infrastructure that supports individual and

  10. Advances in Gamma-Ray Imaging with Intensified Quantum-Imaging Detectors

    Science.gov (United States)

    Han, Ling

    Nuclear medicine, an important branch of modern medical imaging, is an essential tool for both diagnosis and treatment of disease. As the fundamental element of nuclear medicine imaging, the gamma camera is able to detect gamma-ray photons emitted by radiotracers injected into a patient and form an image of the radiotracer distribution, reflecting biological functions of organs or tissues. Recently, an intensified CCD/CMOS-based quantum detector, called iQID, was developed in the Center for Gamma-Ray Imaging. Originally designed as a novel type of gamma camera, iQID demonstrated ultra-high spatial resolution (advancing this conceptually-proven gamma-ray imaging technology to make it ready for both preclinical and clinical applications. To start with, a Monte Carlo simulation of the key light-intensification device, i.e. the image intensifier, was developed, which revealed the dominating factor(s) that limit energy resolution performance of the iQID cameras. For preclinical imaging applications, a previously-developed iQID-based single-photon-emission computed-tomography (SPECT) system, called FastSPECT III, was fully advanced in terms of data acquisition software, system sensitivity and effective FOV by developing and adopting a new photon-counting algorithm, thicker columnar scintillation detectors, and system calibration method. Originally designed for mouse brain imaging, the system is now able to provide full-body mouse imaging with sub-350-micron spatial resolution. To further advance the iQID technology to include clinical imaging applications, a novel large-area iQID gamma camera, called LA-iQID, was developed from concept to prototype. Sub-mm system resolution in an effective FOV of 188 mm x 188 mm has been achieved. The camera architecture, system components, design and integration, data acquisition, camera calibration, and performance evaluation are presented in this work. Mounted on a castered counter-weighted clinical cart, the camera also features

  11. Influence of an intensified competition on fatigue and match performance in junior rugby league players.

    Science.gov (United States)

    Johnston, Rich D; Gabbett, Tim J; Jenkins, David G

    2013-09-01

    The aim of this study was to assess the physiological responses to an intensified rugby league competition and explore the relationships between fatigue and match performance. Prospective cohort study. Fifteen junior rugby league players (n=8 forwards, 7 backs; mean±SE, age 16.6±0.2 years; body mass 81.6±3.0kg; and height 178.9±1.8cm) competed in five 40min games over 5 days (two games each on days 1 and 2, one game on day 4, and no games on days 3 and 5). Over the competition, players performed a countermovement jump to assess neuromuscular fatigue, provided a fingertip blood sample to measure blood creatine kinase, and completed a questionnaire to monitor perceived wellbeing; ratings of perceived effort were recorded following each game. Global positioning system and video analysis of each game were used to assess match performance. Over the first 3 days, there were progressive and large increases in neuromuscular fatigue which peaked 12h after game 4 (forwards ES=4.45, p=0.014; backs ES=3.62, p=0.029), and muscle damage which peaked 1h post game 4 (forwards ES=4.45, p=0.004; backs ES=3.94 p=0.012), as well as reductions in perceived wellbeing. These measures gradually recovered over the final 2 days of the competition. Compared to the backs, the forwards experienced greater increases in creatine kinase following game 2 (ES=1.30) and game 4 (ES=1.24) and reductions in perceived wellbeing (ES=0.25-0.46). Match intensity, high-speed running, and repeated-high intensity effort bouts decreased in games 4 and 5 of the competition. Small to large associations were observed between the changes in fatigue, muscle damage and match performance, with significant correlations between creatine kinase and repeated high-intensity effort bout number (r=-0.70, p=0.031) and frequency (r=0.74, p=0.002) and low-speed activity (r=-0.56, p=0.029). Fatigue and muscle damage accumulate over an intensified competition, which is likely to contribute to reductions in high

  12. Psychological effects of the intensified follow-up of the CEAwatch trial after treatment for colorectal cancer

    NARCIS (Netherlands)

    Zhan, Zhuozhao; Verberne, Charlotte J.; van den Heuvel, Edwin R.; Grossmann, Irene; Ranchor, Adelita V.; Wiggers, Theo; de Bock, Geertruida H.

    2017-01-01

    Background: The aim of the study was to evaluate psychological effects of the state-of-art intensified follow-up protocol for colorectal cancer patients in the CEAwatch trial. Method: At two time points during the CEAwatch trial questionnaires regarding patients' attitude towards follow-up,

  13. Effect of intensified training on muscle ion kinetics, fatigue development and repeated short term performance in endurance trained cyclists

    DEFF Research Database (Denmark)

    Gunnarsson, Thomas Gunnar Petursson; Christensen, Peter Møller; Thomassen, Martin

    2013-01-01

    The effects of intensified training in combination with a reduced training volume on muscle ion kinetics, transporters and work capacity were examined. Eight well-trained cyclists replaced their regular training with speed-endurance training (12x30-s sprints) 2-3 times per wk and aerobic high...

  14. High incidence of pseudotumours after hip resurfacing even in low risk patients; results from an intensified MRI screening protocol.

    NARCIS (Netherlands)

    Weegen, W. van der; Smolders, J.M.; Sijbesma, T.; Hoekstra, H.J.; Brakel, K.; Susante, J.L.C. van

    2013-01-01

    We intensified our screening protocol for the presence of pseudotumours in a consecutive series of patients with a hip resurfacing arthroplasty (HRA), to establish whether we should be alert to the presence of 'silent' pseudotumours. Patients categorised with high risk (11 hips) and low risk (10

  15. A randomized trial of insulin aspart with intensified basal NPH insulin supplementation in people with Type 1 diabetes

    NARCIS (Netherlands)

    DeVries, J. H.; Lindholm, A.; Jacobsen, J. L.; Heine, R. J.; Home, P. D.

    2003-01-01

    Aims Insulin aspart has been shown to improve post-prandial and overall glycaemic control in people with Type 1 diabetes. We hypothesized that insulin aspart with intensified basal NPH insulin supplementation would result in better overall glycaemic control than human regular insulin with standard

  16. Intensified nitrogen and phosphorus removal in a novel electrolysis-integrated tidal flow constructed wetland system.

    Science.gov (United States)

    Ju, Xinxin; Wu, Shubiao; Zhang, Yansheng; Dong, Renjie

    2014-08-01

    A novel electrolysis-integrated tidal flow constructed wetland (CW) system was developed in this study. The dynamics of intensified nitrogen and phosphorus removal and that of hydrogen sulphide control were evaluated. Ammonium removal of up to 80% was achieved with an inflow concentration of 60 mg/L in wetland systems with and without electrolysis integration. Effluent nitrate concentration decreased from 2 mg/L to less than 0.5 mg/L with the decrease in current intensity from 1.5 mA/cm(2) to 0.57 mA/cm(2) in the electrolysis-integrated wetland system, thus indicating that the current intensity of electrolysis plays an important role in nitrogen transformations. Phosphorus removal was significantly enhanced, exceeding 95% in the electrolysis-integrated CW system because of the in-situ formation of a ferric iron coagulant through the electro-dissolution of a sacrificial iron anode. Moreover, the electrolyzed wetland system effectively inhibits sulphide accumulation as a result of a sulphide precipitation coupled with ferrous-iron electro-dissolution and/or an inhibition of bacterial sulphate reduction under increased aerobic conditions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Probabilistic discrimination between large-scale environments of intensifying and decaying African Easterly Waves

    Energy Technology Data Exchange (ETDEWEB)

    Agudelo, Paula A. [Area Hidrometria e Instrumentacion Carrera, Empresas Publicas de Medellin, Medellin (Colombia); Hoyos, Carlos D.; Curry, Judith A.; Webster, Peter J. [School of Earth and Atmospheric Sciences, Georgia Institute of Technology, Atlanta, GA (United States)

    2011-04-15

    About 50-60% of Atlantic tropical cyclones (TCs) including nearly 85% of intense hurricanes have their origins as African Easterly Waves (AEWs). However, predicting the likelihood of AEW intensification remains a difficult task. We have developed a Bayesian diagnostic methodology to understand genesis of North Atlantic TCs spawned by AEWs through the examination of the characteristics of the AEW itself together with the large-scale environment, resulting in a probabilistic discrimination between large-scale environments associated with intensifying and decaying AEWs. The methodology is based on a new objective and automatic AEW tracking scheme used for the period 1980 to 2001 based on spatio-temporally Fourier-filtered relative vorticity and meridional winds at different levels and outgoing long wave radiation. Using the AEW and Hurricane Best Track Files (HURDAT) data sets, probability density functions of environmental variables that discriminate between AEWs that decay, become TCs or become major hurricanes are determined. Results indicate that the initial amplitude of the AEWs is a major determinant for TC genesis, and that TC genesis risk increases when the wave enters an environment characterized by pre-existing large-scale convergence and moist convection. For the prediction of genesis, the most useful variables are column integrated heating, vertical velocity and specific humidity, and a combined form of divergence and vertical velocity and SST. It is also found that the state of the large-scale environment modulates the annual cycle and interannual variability of the AEW intensification efficiency. (orig.)

  18. Intensifying the Casimir force between two silicon substrates within three different layers of materials

    International Nuclear Information System (INIS)

    Seyedzahedi, A.; Moradian, A.; Setare, M.R.

    2016-01-01

    We investigate the Casimir force for a system composed of two thick slabs as substrates within three different homogeneous layers. We use the scattering approach along with the Matsubara formalism in order to calculate the Casimir force at finite temperature. First, we focus on constructing the reflection matrices and then we calculate the Casimir force for a water–lipid system. According to the conventional use of silicon as a substrate, we apply the formalism to calculate the Casimir force for layers of Au, VO 2 , mica, KCl and foam rubber on the thick slabs of silicon. Afterwards, introducing an increasing factor, we compare our results with Lifshitz force in the vacuum between two semispaces of silicon in order to illustrate the influence of the layers on intensifying the Casimir force. We also calculate the Casimir force between two slabs of the forementioned materials with finite thicknesses to indicate the substrate's role in increasing the obtained Casimir force. Our simple calculation is interesting since one can extend it along with the Rigorous Coupled Wave Analysis to systems containing inhomogeneous layers as good candidates for designing nanomechanical devices.

  19. Intensifying the Casimir force between two silicon substrates within three different layers of materials

    Energy Technology Data Exchange (ETDEWEB)

    Seyedzahedi, A. [Department of Science, University of Kurdistan, Sanandaj (Iran, Islamic Republic of); Moradian, A., E-mail: a.moradian@uok.ac.ir [Department of Science, Campus of Bijar, University of Kurdistan, Bijar (Iran, Islamic Republic of); Setare, M.R., E-mail: rezakord@ipm.ir [Department of Science, University of Kurdistan, Sanandaj (Iran, Islamic Republic of)

    2016-04-01

    We investigate the Casimir force for a system composed of two thick slabs as substrates within three different homogeneous layers. We use the scattering approach along with the Matsubara formalism in order to calculate the Casimir force at finite temperature. First, we focus on constructing the reflection matrices and then we calculate the Casimir force for a water–lipid system. According to the conventional use of silicon as a substrate, we apply the formalism to calculate the Casimir force for layers of Au, VO{sub 2}, mica, KCl and foam rubber on the thick slabs of silicon. Afterwards, introducing an increasing factor, we compare our results with Lifshitz force in the vacuum between two semispaces of silicon in order to illustrate the influence of the layers on intensifying the Casimir force. We also calculate the Casimir force between two slabs of the forementioned materials with finite thicknesses to indicate the substrate's role in increasing the obtained Casimir force. Our simple calculation is interesting since one can extend it along with the Rigorous Coupled Wave Analysis to systems containing inhomogeneous layers as good candidates for designing nanomechanical devices.

  20. Study on isothermal precision forging process of rare earth intensifying magnesium alloy

    International Nuclear Information System (INIS)

    Shan, Debin; Xu, Wenchen; Han, Xiuzhu; Huang, Xiaolei

    2012-01-01

    A three dimensional rigid-plastic finite element model is established to simulate the isothermal precision forging process of the magnesium alloy bracket based on DEFORM 3D in order to analyze the material flow rule and determine the forging process scheme. Some problems such as underfilling and too large forging pressure are predicted and resolved through optimizing the shapes of the billet successfully. Compared to the initial microstructure, the isothermal-forged microstructure of the alloy refines obviously and amounts of secondary phases precipitate on the matrix during isothermal forging process. In subsequent ageing process, large quantities of secondary phases precipitate from α-Mg matrix with increasing ageing time. The optimal comprehensive mechanical properties of the alloy have been obtained after aged at 473 K, 63 h with the ultimate tensile strength, tensile yield strength and elongation 380 MPa, 243 MPa and 4.07% respectively, which shows good potential for application of isothermal forging process of rare earth intensifying magnesium alloy.

  1. intensifying and reorienting transfer of low carbon technologies for climate change prevention

    International Nuclear Information System (INIS)

    Pisani-Ferry, Jean; Monange, Herve; Gorges, Delphine; Senne, Valerie; Roulle, Jean-Michel

    2013-10-01

    The transfer of 'low carbon' technologies is crucial in order to moderate greenhouse gas (GHG) emissions by developing countries, which are set to rise significantly. Their implementation will determine the success of a global agreement on climate change in 2015, and this is the task of the Technology Mechanism, created in 2010. This policy brief sets out the principal results of a study commissioned from the Mines ParisTech Industrial Economics Centre (CERNA). The study shows that, unlike China, Mexico, South Africa and, to a lesser extent, Brazil, India is currently left out of international flows of low carbon technologies transfer - it is therefore a top priority, as is the rest of developing Asia, Africa and Eastern Europe. To intensify these transfers, ambitious greenhouse gas emissions reduction policies need to be implemented and absorptive capacities need to be created in countries that receive such technologies. In emerging countries, which possess a genuine capacity for innovation, and which are involved in international trade, the strengthening of intellectual property rights and the lowering of barriers to trade and investment are to be recommended. However, in the least developed countries, emphasis must be placed on technology absorptive capacities and in particular on the development of a qualified labour force

  2. Root growth of tomato seedlings intensified by humic substances from peat bogs

    Directory of Open Access Journals (Sweden)

    Alexandre Christofaro Silva

    2011-10-01

    Full Text Available Peats are an important reserve of humified carbon in terrestrial ecosystems. The interest in the use of humic substances as plant growth promoters is continuously increasing. The objective of this study was to evaluate the bioactivity of alkaline soluble humic substances (HS, humic (HA and fulvic acids (FA isolated from peats with different decomposition stages of organic matter (sapric, fibric and hemic in the Serra do Espinhaço Meridional, state of Minas Gerais. Dose-response curves were established for the number of lateral roots growing from the main plant axis of tomato seedlings. The bioactivity of HA was greatest (highest response in lateral roots at lowest concentration while FA did not intensify root growth. Both HS and HA stimulated root hair formation. At low concentrations, HS and HA induced root hair formation near the root cap, a typical hormonal imbalance effect in plants. Transgenic tomato with reporter gene DR5::GUS allowed the observation that the auxin-related signalling pathway was involved in root growth promotion by HA.

  3. Paediatric interventional cardiology: flat detector versus image intensifier using a test object

    Science.gov (United States)

    Vano, E.; Ubeda, C.; Martinez, L. C.; Leyton, F.; Miranda, P.

    2010-12-01

    Entrance surface air kerma (ESAK) values and image quality parameters were measured and compared for two biplane angiography x-ray systems dedicated to paediatric interventional cardiology, one equipped with image intensifiers (II) and the other one with dynamic flat detectors (FDs). Polymethyl methacrylate phantoms of different thicknesses, ranging from 8 to 16 cm, and a Leeds TOR 18-FG test object were used. The parameters of the image quality evaluated were noise, signal-difference-to-noise ratio (SdNR), high contrast spatial resolution (HCSR) and three figures of merit combining entrance doses and signal-to-noise ratios or HCSR. The comparisons showed a better behaviour of the II-based system in the low contrast region over the whole interval of thicknesses. The FD-based system showed a better performance in HCSR. The FD system evaluated would need around two times more dose than the II system evaluated to reach a given value of SdNR; moreover, a better spatial resolution was measured (and perceived in conventional monitors) for the system equipped with flat detectors. According to the results of this paper, the use of dynamic FD systems does not lead to an automatic reduction in ESAK or to an automatic improvement in image quality by comparison with II systems. Any improvement also depends on the setting of the x-ray systems and it should still be possible to refine these settings for some of the dynamic FDs used in paediatric cardiology.

  4. Using a Non-Fit Message Helps to De-Intensify Negative Reactions to Tough Advice

    Science.gov (United States)

    Fridman, Ilona; Scherr, Karen; Glare, Paul; Higgins, E. Tory

    2017-01-01

    Sometimes physicians need to provide patients with potentially upsetting advice. For example, physicians may recommend hospice for a terminally ill patient because it best meets their needs, but the patient and their family dislike this advised option. We explore whether regulatory non-fit could be used to improve these types of situations. Across five studies in which participants imagined receiving upsetting advice from a physician, we demonstrate that regulatory non-fit between the form of the physician’s advice (emphasizing gains vs. avoiding losses) and the participants’ motivational orientation (promotion vs. prevention) improves participants’ evaluation of an initially disliked option. Regulatory non-fit de-intensifies participants’ initial attitudes by making them less confident in their initial judgments and motivating them to think more thoroughly about the arguments presented. Furthermore, consistent with previous research on regulatory fit, we showed that the mechanism of regulatory non-fit differs as a function of participants’ cognitive involvement in the evaluation of the option. PMID:27341845

  5. Real-Time Detection of Sporadic Meteors in the Intensified TV Imaging Systems.

    Science.gov (United States)

    Vítek, Stanislav; Nasyrova, Maria

    2017-12-29

    The automatic observation of the night sky through wide-angle video systems with the aim of detecting meteor and fireballs is currently among routine astronomical observations. The observation is usually done in multi-station or network mode, so it is possible to estimate the direction and the speed of the body flight. The high velocity of the meteorite flying through the atmosphere determines the important features of the camera systems, namely the high frame rate. Thanks to high frame rates, such imaging systems produce a large amount of data, of which only a small fragment has scientific potential. This paper focuses on methods for the real-time detection of fast moving objects in the video sequences recorded by intensified TV systems with frame rates of about 60 frames per second. The goal of our effort is to remove all unnecessary data during the daytime and make free hard-drive capacity for the next observation. The processing of data from the MAIA (Meteor Automatic Imager and Analyzer) system is demonstrated in the paper.

  6. Can we Observe and Assess Whether the Global Hydrological Cycle is "Intensifying"?

    Science.gov (United States)

    Wood, E. F.; Sheffield, J.

    2012-12-01

    There is controversy over whether the hydrological cycle is "intensifying" (or "accelerating"), and if so how and where? Resolving this critical question is a central goal of both national (e.g. NASA's Energy and Water cycle Study: NEWS) and international (WCRP Global Energy and Water cycle Experiment: GEWEX) programs. Its resolution has significant implications for understanding changes in hydroclimatic states and variability, and in future water security at regional to global scales. Over the last decade a number of papers have addressed trends and change in specific water cycle variables with results that can best be described as inconclusive, regardless of the conclusions of specific papers. In this presentation a number of recent studies will be reviewed for their consistency in assessing whether collectively one can make conclusions regarding how the hydrologic cycle is changing. The presentation will also demonstrate a pathway for analyzing where to observe for the detection of change based on a NASA-supported, global, 1983-2009, terrestrial water cycle Earth System Data Record project being led by the author. Initial results will be presented and a discussion presented on the extent that the proposed strategy can be used to detect change in the terrestrial hydrological cycle.

  7. BaFCl:Eu2+, a new phosphor for X-ray-intensifying screens

    International Nuclear Information System (INIS)

    Stevels, A.L.N.; Pingault, F.

    1975-01-01

    A number of phosphors for X-ray-intensifying screens have been evaluated by calculating figures of merit. On use in combination with standard (''blue''-sensitive) X-ray film, BaFCl:Eu 2+ and BaFBr:Eu 2+ give better performance than the traditional CaWO 4 and more recently developed UV or blue-emitting materials (e.g., sulphates and y-oxysulphides). The calculated figures of merit of BaFCl:Eu 2+ or BaFBr:Eu 2+ /standard-film combinations are comparable to those of Gd 2 O 2 S:Tb/green-sensitive X-ray film systems. The preparation of optimal fluorohalide:Eu 2+ phosphors involves proper formation of the host lattice, complete reduction of Eu 3+ ions as well as elimination of afterglow. Measurements on powders and experimental screens indicate that by using BaFCl:Eu 2+ screens in radiography, important dose reductions can be achieved without the necessity of using other than standard (''blue''-sensitive) X-ray films

  8. Sensitometry of intensifying screen-film system for detection of yearly change of imaging quality factors

    International Nuclear Information System (INIS)

    Yoshida, Akira; Asahara, Masayoshi

    2002-01-01

    Systematic sensitometry of 20 green- and 25 blue-intensifying screens made in early 1980s and early 1990s was performed on their physical imaging qualities to evaluate their yearly change. Sensitometry was done with Toshiba KXO-1000 X-ray generator (Tube: Toshiba DRX-431HD, 80 kV, 20 mm-thick Al-filter), characteristic curve examination with KXO-15 (Tube: DRX-1603B, 80 kV, 0.5 mm Cu+4.0 mm Al), determination of modulation transfer function with KXO-15 (Tube: DRX-1303B, 80 kV, 2.0 mm Al), and Wiener spectrometry with Hitachi DH-158 (Tube: Hitachi UH-6GC-108DL, 80 kV, 20 mmAl). Reference screen was that reported by US Bureau of Radiological Health (1982) and Center for Devices and Radiological Health (196) and was obtained from Chicago University. There were products without yearly change, with increased sensitivity with unchanged resolution and noise level, with improved resolution, or with improved sensitivity. (K.H.)

  9. Intensified summer monsoon and the urbanization of Indus Civilization in northwest India.

    Science.gov (United States)

    Dixit, Yama; Hodell, David A; Giesche, Alena; Tandon, Sampat K; Gázquez, Fernando; Saini, Hari S; Skinner, Luke C; Mujtaba, Syed A I; Pawar, Vikas; Singh, Ravindra N; Petrie, Cameron A

    2018-03-09

    Today the desert margins of northwest India are dry and unable to support large populations, but were densely occupied by the populations of the Indus Civilization during the middle to late Holocene. The hydroclimatic conditions under which Indus urbanization took place, which was marked by a period of expanded settlement into the Thar Desert margins, remains poorly understood. We measured the isotopic values (δ 18 O and δD) of gypsum hydration water in paleolake Karsandi sediments in northern Rajasthan to infer past changes in lake hydrology, which is sensitive to changing amounts of precipitation and evaporation. Our record reveals that relatively wet conditions prevailed at the northern edge of Rajasthan from ~5.1 ± 0.2 ka BP, during the beginning of the agricultural-based Early Harappan phase of the Indus Civilization. Monsoon rainfall intensified further between 5.0 and 4.4 ka BP, during the period when Indus urban centres developed in the western Thar Desert margin and on the plains of Haryana to its north. Drier conditions set in sometime after 4.4 ka BP, and by ~3.9 ka BP an eastward shift of populations had occurred. Our findings provide evidence that climate change was associated with both the expansion and contraction of Indus urbanism along the desert margin in northwest India.

  10. Paediatric interventional cardiology: flat detector versus image intensifier using a test object

    Energy Technology Data Exchange (ETDEWEB)

    Vano, E [Radiology Department, Medicine School, Complutense University and San Carlos University Hospital, 28040 Madrid (Spain); Ubeda, C [Clinical Sciences Department, Faculty of the Science of Health and CIHDE, Tarapaca University, 18 de Septiembre 2222, Arica (Chile); Martinez, L C [Medical Physics and Radiation Protection Service, 12 de Octubre University Hospital, Madrid (Spain); Leyton, F [Institute of Public Health of Chile, Marathon 1000, Nunoa, Santiago (Chile); Miranda, P, E-mail: eliseov@med.ucm.e [Hemodynamic Department, Cardiovascular Service, Luis Calvo Mackenna Hospital, Avenida Antonio Varaas 360, Providencia, Santiago (Chile)

    2010-12-07

    Entrance surface air kerma (ESAK) values and image quality parameters were measured and compared for two biplane angiography x-ray systems dedicated to paediatric interventional cardiology, one equipped with image intensifiers (II) and the other one with dynamic flat detectors (FDs). Polymethyl methacrylate phantoms of different thicknesses, ranging from 8 to 16 cm, and a Leeds TOR 18-FG test object were used. The parameters of the image quality evaluated were noise, signal-difference-to-noise ratio (SdNR), high contrast spatial resolution (HCSR) and three figures of merit combining entrance doses and signal-to-noise ratios or HCSR. The comparisons showed a better behaviour of the II-based system in the low contrast region over the whole interval of thicknesses. The FD-based system showed a better performance in HCSR. The FD system evaluated would need around two times more dose than the II system evaluated to reach a given value of SdNR; moreover, a better spatial resolution was measured (and perceived in conventional monitors) for the system equipped with flat detectors. According to the results of this paper, the use of dynamic FD systems does not lead to an automatic reduction in ESAK or to an automatic improvement in image quality by comparison with II systems. Any improvement also depends on the setting of the x-ray systems and it should still be possible to refine these settings for some of the dynamic FDs used in paediatric cardiology.

  11. Comparison of dose and image quality of a Flat-panel detector and an image intensifier

    International Nuclear Information System (INIS)

    Lazzaro, M.; Friedrich, B.Q.; Luz, R.M. da; Silva, A.M.M. da

    2016-01-01

    With the development of new technologies, have emerged new conversion methods of X-ray image, such as flat panel detectors. The aim of this work is the comparison of entrance surface air kerma (ESAK) and image quality between an image intensifier type of detector (A) and a flat panel (B). The ESAK was obtained by placing a ionization chamber under PMMA simulators of 10, 20 and 30 cm and the image quality was obtained by using the TOR "1"8FG simulator. The ESAK to the equipment A is higher when compared to the equipment B. The high contrast resolution is better for the equipment A for all thicknesses of simulators. The equipment A has low contrast resolution with a better viewing threshold for thicknesses of 10 and 20 cm, and a worse performance for 30 cm. It is concluded that the equipment B has ESAK smaller and despite having lower resolution, in almost all cases, have appropriate image quality for diagnosis. (author)

  12. Star tracking method based on multiexposure imaging for intensified star trackers.

    Science.gov (United States)

    Yu, Wenbo; Jiang, Jie; Zhang, Guangjun

    2017-07-20

    The requirements for the dynamic performance of star trackers are rapidly increasing with the development of space exploration technologies. However, insufficient knowledge of the angular acceleration has largely decreased the performance of the existing star tracking methods, and star trackers may even fail to track under highly dynamic conditions. This study proposes a star tracking method based on multiexposure imaging for intensified star trackers. The accurate estimation model of the complete motion parameters, including the angular velocity and angular acceleration, is established according to the working characteristic of multiexposure imaging. The estimation of the complete motion parameters is utilized to generate the predictive star image accurately. Therefore, the correct matching and tracking between stars in the real and predictive star images can be reliably accomplished under highly dynamic conditions. Simulations with specific dynamic conditions are conducted to verify the feasibility and effectiveness of the proposed method. Experiments with real starry night sky observation are also conducted for further verification. Simulations and experiments demonstrate that the proposed method is effective and shows excellent performance under highly dynamic conditions.

  13. Climate change and ocean deoxygenation within intensified surface-driven upwelling circulations.

    Science.gov (United States)

    Bakun, Andrew

    2017-09-13

    Ocean deoxygenation often takes place in proximity to zones of intense upwelling. Associated concerns about amplified ocean deoxygenation arise from an arguable likelihood that coastal upwelling systems in the world's oceans may further intensify as anthropogenic climate change proceeds. Comparative examples discussed include the uniquely intense seasonal Somali Current upwelling, the massive upwelling that occurs quasi-continuously off Namibia and the recently appearing and now annually recurring 'dead zone' off the US State of Oregon. The evident 'transience' in causal dynamics off Oregon is somewhat mirrored in an interannual-scale intermittence in eruptions of anaerobically formed noxious gases off Namibia. A mechanistic scheme draws the three examples towards a common context in which, in addition to the obvious but politically problematic remedy of actually reducing 'greenhouse' gas emissions, the potentially manageable abundance of strongly swimming, finely gill raker-meshed small pelagic fish emerges as a plausible regulating factor.This article is part of the themed issue 'Ocean ventilation and deoxygenation in a warming world'. © 2017 The Author(s).

  14. Multiscale hydrodynamic investigation to intensify the biogas production in upflow anaerobic reactors.

    Science.gov (United States)

    Jiang, Jiankai; Wu, Jing; Zhang, Jinbai; Poncin, Souhila; Li, Huai Z

    2014-03-01

    Hydrodynamics plays a main role for the performance of an anaerobic reactor involving three phases: wastewater, sludge granules and biogas bubbles. The present work was focused on an original approach to investigate the hydrodynamics at different scales and then to intensify the performance of such complex reactors. The experiments were carried out respectively in a 3D reactor at macroscale, a 2D reactor at mesoscale and a 1D anaerobic reactor at microscale. A Particle Image Velocimetry (PIV), a micro-PIV and a high-speed camera were employed to quantify the liquid flow fields and the relative motion between sludge granules and bubbles. Shear rates exerted on sludge granules were quantified from liquid flow fields. The optimal biogas production is obtained at mean shear rate varying from 28 to 48s(-1), which is controlled by two antagonistic mechanisms. The multiscale approach demonstrates pertinent mechanisms proper to each scale and allows a better understanding of such reactors. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Digital fluorimeter

    International Nuclear Information System (INIS)

    Mello, H.A. de.

    1980-11-01

    The specifications of a digital fluorimeter. That with adequated analytical techniques permits to determine trace amounts of fluorescents materials in samples, are described. The fluorimeter is of the reflection type, and uses fluorescents lamps for the excitation and an optical system which is connected to a photomultiplyer machine and permits the measurement of the light intensity. In the case of IEN (Instituto de Engenharia Nuclear) the equipment is used for to determine the uranium content in sample materials to be exported. The precision of the instrument is about + - 1% in the scale of 0.1 which is the normally one used in the current researchs. (E.G.) [pt

  16. Digital entrepreneurship

    DEFF Research Database (Denmark)

    Brem, Alexander; Richter, Chris; Kraus, Sascha

    2017-01-01

    comprising guided interviews with 14 companies from Germany, Austria and Switzerland provides detailed insights into different aspects of the sharing economy phenomenon. Our results make a direct contribution to sharing economy research, especially regarding the new business models of start-ups. Here, we...... find a clear difference between the relevance of economic and social orientation. The latter appears to be in higher demand among customers than entrepreneurs. The increasingly digitalized environment has led to a changed living situation characterized by urbanity, openness to new solutions, changed...

  17. Focus: Digital

    DEFF Research Database (Denmark)

    Technology has been an all-important and defining element within the arts throughout the 20th century, and it has fundamentally changed the ways in which we produce and consume music. With this Focus we investigate the latest developments in the digital domain – and their pervasiveness and rapid...... production and reception of contemporary music and sound art. With ‘Digital’ we present four composers' very different answers to how technology impact their work. To Juliana Hodkinson it has become an integral part of her sonic writing. Rudiger Meyer analyses the relationships between art and design and how...

  18. Digitalization and networking of analog simulators and portal images

    Energy Technology Data Exchange (ETDEWEB)

    Pesznyak, C.; Zarand, P.; Mayer, A. [Uzsoki Hospital, Budapest (Hungary). Inst. of Oncoradiology

    2007-03-15

    Background: Many departments have analog simulators and irradiation facilities (especially cobalt units) without electronic portal imaging. Import of the images into the R and V (Record and Verify) system is required. Material and Methods: Simulator images are grabbed while portal films scanned by using a laser scanner and both converted into DICOM RT (Digital Imaging and Communications in Medicine Radiotherapy) images. Results: Image intensifier output of a simulator and portal films are converted to DICOM RT images and used in clinical practice. The simulator software was developed in cooperation at the authors' hospital. Conclusion: The digitalization of analog simulators is a valuable updating in clinical use replacing screen-film technique. Film scanning and digitalization permit the electronic archiving of films. Conversion into DICOM RT images is a precondition of importing to the R and V system. (orig.)

  19. Digitalization and networking of analog simulators and portal images.

    Science.gov (United States)

    Pesznyák, Csilla; Zaránd, Pál; Mayer, Arpád

    2007-03-01

    Many departments have analog simulators and irradiation facilities (especially cobalt units) without electronic portal imaging. Import of the images into the R&V (Record & Verify) system is required. Simulator images are grabbed while portal films scanned by using a laser scanner and both converted into DICOM RT (Digital Imaging and Communications in Medicine Radiotherapy) images. Image intensifier output of a simulator and portal films are converted to DICOM RT images and used in clinical practice. The simulator software was developed in cooperation at the authors' hospital. The digitalization of analog simulators is a valuable updating in clinical use replacing screen-film technique. Film scanning and digitalization permit the electronic archiving of films. Conversion into DICOM RT images is a precondition of importing to the R&V system.

  20. Digital Humanities

    DEFF Research Database (Denmark)

    Nielsen, Hans Jørn

    2015-01-01

    overgangen fra trykkekultur til digital kultur. For det første problemstillingen omkring digitalisering af litterær kulturarv med fokus på kodning og tagging af teksten samt organisering i hypertekststrukturer. For det andet reorganiseringen af det digitale dokument i dataelementer og database. For det......Artiklen præsenterer først nogle generelle problemstillinger omkring Digital Humanities (DH) med det formål at undersøge dem nærmere i relation til konkrete eksempler på forskellige digitaliseringsmåder og ændringer i dokumentproduktion. I en nærmere afgrænsning vælger artiklen den tendens i DH......, der betragter DH som forbundet med "making" og "building" af digitale objekter og former. Dette kan også karakteriseres som DH som praktisk-produktiv vending. Artiklen har valgt tre typer af digitalisering. De er valgt ud fra, at de skal repræsentere forskellige måder at håndtere digitaliseringen på...

  1. Intuitive Choices Lead to Intensified Positive Emotions: An Overlooked Reason for "Intuition Bias"?

    Science.gov (United States)

    Kirkebøen, Geir; Nordbye, Gro H H

    2017-01-01

    People have, for many well-documented reasons, a tendency to overemphasize their intuitions and to follow them, even when they should not. This "intuition bias" leads to several kinds of specific intuitive biases in judgments and decision making. Previous studies have shown that characteristics of the decision process have a tendency to "leak" into the experience of the choice outcome. We explore whether intuitive choices influence the experience of the choice outcomes differently from "non-intuitive," analytic choices. Since intuition is feeling based, we examine in particular if intuitive choices have stronger affective consequences than non-intuitive ones. Participants in two scenario studies ( N = 90; N = 126) rated the feelings of decision makers who experienced a conflict between two options, one intuitively appealing and another that appeared preferable on analytic grounds. Choosing the intuitive alternative was anticipated to lead to somewhat more regret after negative outcomes and, in particular, much more satisfaction with positive outcomes. In two autobiographical studies, one with psychology students ( N = 88) and the other with experienced engineers ( N = 99), participants were asked to provide examples of choice conflicts between an intuitive and a non-intuitive option from their own private or professional lives. Both groups showed a tendency to report stronger emotions, in particular positive, after intuitive choices. One well-established explanation for intuition bias focuses on the nature of people's anticipated negative counterfactual thoughts if their decisions were to turn out badly. The present data indicate that intuitive choices intensify positive emotions, anticipated and real, after successful outcomes much more than negative emotions after failures. Positive outcomes are also more commonly expected than negative ones, when we make choices. We argue that markedly amplified emotions, mediated by stronger personal involvement, in the

  2. Intensified association between waist circumference and hypertension in abdominally overweight children.

    Science.gov (United States)

    Dong, Bin; Wang, Zhiqiang; Yang, Yide; Wang, Hai-Jun; Ma, Jun

    2016-01-01

    Abdominal adiposity is an important risk factor for childhood hypertension. The present study aimed to compare the strength of the association between waist circumference (WC) and hypertension in children with different WC levels. A total of 82,413 Chinese children aged 9-17 years were selected. An abdominally overweight child was defined as a child with WC ≥75th sex- and age-specific percentile. Hypertension was categorised as ≥95th sex-, age- and height-specific percentile. Logistic regression model was applied to calculate the odds ratio (OR) and 95% confidence interval (CI) of WC for hypertension after WC was transformed into sex- and age-specific z-score. Abdominally overweight children presented a higher risk of hypertension (OR: 2.39; 95% CI: 2.26, 2.54) than children with normal WC. In children with normal WC, one sex- and age-specific standard deviation increase in WC was associated with a 42% increase in odds of hypertension (OR: 1.42; 95% CI: 1.30, 1.55). That increase was elevated to 74% in abdominally overweight children (OR: 1.74; 95% CI: 1.66, 1.82). A similar pattern was also observed in different sex and area groups, and in children 9-14 years old. An intensified association between WC and hypertension was observed in abdominally overweight Chinese children. The gain in WC was associated with greater increase in hypertensive risk in abdominally overweight children than that of children with normal WC. These findings could improve intervention strategies for hypertension risk reduction in children. Copyright © 2015 Asia Oceania Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.

  3. Application of an image intensifier to the study on hadrons in air shower, 4

    International Nuclear Information System (INIS)

    Tsushima, Itsuro; Kawasumi, Norio; Hashimoto, Katsumi; Machida, Masaharu

    1975-01-01

    As the apparatus for observing cosmic ray air shower, the particle detection apparatus combining spark chamber, scintillator and photomultiplier tube is frequently used, but the exact detection of particle number is impossible with it when particle density is large. The authors have carried out the experiment to measure nuclear active particles in air shower and to grasp the central part of air shower as energy flow by utilizing an image intensifier tube. On the roof of building S, a laboratory was built, and a core detector of 2 m x 2 m area, 13 AS detectors of 0.25 m 2 and an AS detector of 1 m 2 were installed. The gate of the II was opened by utilizing coincidence pulses, and the position and amount of scintillation in the core detector was taken into a camera through the II. The time of observation was 289 hours, and the time of II operation was 113 hours. Total number of air shower recorded was 218 cases, and the centers of 120 cases among them were determined in the AS detectors at four corners. The centers of 39 cases were within the area of the core detector. In the coincident counting of air shower and burst carried out in the present experiment, the total delay time from the arrival of air shower to the gate pulse actuating the II was 1.6 sec. The core of air shower of about 10 6 size and 1.3 age was caught by this method. The problems for future are the determination of core position for the air shower of smaller size, and the meaning of spot images of II. (Kako, I.)

  4. Savings from controlled measurement operations during the selection of the methods of intensifying inflows

    Energy Technology Data Exchange (ETDEWEB)

    Pluden, I A

    1979-01-01

    Investigation was made of the effectiveness of the information preservation of problems on the selection of the methods of the intensification of the extraction of petroleum. On the basis of the methodology on the determination of the operational outlay for each well and the cost of the extraction of petroleum which was worked out by the All-Union Science Research Institute for Gas, the formulae concerning the dependence of the cost on the output of the wells is generalized for the case of flooded wells. Formulae are presented, which are suitable for the calculation of the savings on the application of the methods of intensifying extraction. The output of the wells is examined as a random value. Formulae are deduced for the density of the reliability and the function of the distribution of the cost of the extraction of petroleum per well, and a graph of this function of determination is given. The necessity of taking into consideration the error of the dimensions of measurements of the output of the wells in the calculations is pointed out. This error leads in practice to significant errors in the selection of intensification methods and the evaluation of its effectiveness, which in the last analysis has a significant economic disadvantage. Recommendations are made for showing the elimination of this disadvantage by rational organization of the measurement control operations. A graph is made for the dependence between the duration of the measurements of the outputs of the wells and their frequency per month (periodicity) with various outputs of wells for the case when the error of the measurements of the yields does not exceed /sub +//sub -/5%.

  5. Enzymatically modified isoquercitrin supplementation intensifies plantaris muscle fiber hypertrophy in functionally overloaded mice.

    Science.gov (United States)

    Kohara, Akiko; Machida, Masanao; Setoguchi, Yuko; Ito, Ryouichi; Sugitani, Masanori; Maruki-Uchida, Hiroko; Inagaki, Hiroyuki; Ito, Tatsuhiko; Omi, Naomi; Takemasa, Tohru

    2017-01-01

    Enzymatically modified isoquercitrin (EMIQ) is produced from rutin using enzymatic hydrolysis followed by treatment with glycosyltransferase in the presence of dextrin to add glucose residues. EMIQ is absorbed in the same way as quercetin, a powerful antioxidant reported to prevent disused muscle atrophy by targeting mitochondria and to have ergogenic effects. The present study investigated the effect of EMIQ on skeletal muscle hypertrophy induced by functional overload. In Study 1, 6-week-old ICR male mice were divided into 4 groups: sham-operated control, sham-operated EMIQ, overload-operated control, and overload-operated EMIQ groups. In Study 2, mice were divided into 3 groups: overload-operated whey control, overload-operated whey/EMIQ (low dose), and overload-operated whey/EMIQ (high dose) groups. The functional overload of the plantaris muscle was induced by ablation of the synergist (gastrocnemius and soleus) muscles. EMIQ and whey protein were administered with food. Three weeks after the operation, the cross-sectional area and minimal fiber diameter of the plantaris muscle fibers were measured. In Study 1, functional overload increased the cross-sectional area and minimal fiber diameter of the plantaris muscle. EMIQ supplementation significantly increased the cross-sectional area and minimal fiber diameter of the plantaris muscle in both the sham-operated and overload-operated groups. In Study 2, EMIQ supplementation combined with whey protein administration significantly increased the cross-sectional area and minimal fiber diameter of the plantaris muscle. EMIQ, even when administered as an addition to whey protein supplementation, significantly intensified the fiber hypertrophy of the plantaris muscle in functionally overloaded mice. EMIQ supplementation also induced fiber hypertrophy of the plantaris in sham-operated mice.

  6. Application of intensified heat transfer for the retrofit of heat exchanger network

    International Nuclear Information System (INIS)

    Wang, Yufei; Pan, Ming; Bulatov, Igor; Smith, Robin; Kim, Jin-Kuk

    2012-01-01

    Highlights: → Novel design approach for the retrofit of HEN based on intensified heat transfer. → Development of a mathematical model to evaluate shell-and-tube heat exchanger performances. → Identification of the most appropriate heat exchangers requiring heat transfer enhancements in the heat exchanger network. -- Abstract: A number of design methods have been proposed for the retrofit of heat exchanger networks (HEN) during the last three decades. Although considerable potential for energy savings can be identified from conventional retrofit approaches, the proposed solutions have rarely been adopted in practice, due to significant topology modifications required and resulting engineering complexities during implementation. The intensification of heat transfer for conventional shell-and-tube heat exchangers can eliminate the difficulties of implementing retrofit in HEN which are commonly restricted by topology, safety and maintenance constraints, and includes high capital costs for replacing equipment and pipelines. This paper presents a novel design approach to solve HEN retrofit problems based on heat transfer enhancement. A mathematical model has been developed to evaluate shell-and-tube heat exchanger performances, with which heat-transfer coefficients and pressure drops for both fluids in tube and shell sides are obtained. The developed models have been compared with the Bell-Delaware, simplified Tinker and Wills-Johnston methods and tested with the HTRI (registered) and HEXTRAN (registered) software packages. This demonstrates that the new model is much simpler but can give reliable results in most cases. For the debottlenecking of HEN, four heuristic rules are proposed to identify the most appropriate heat exchangers requiring heat transfer enhancements in the HEN. The application of this new design approach allows a significant improvement in energy recovery without fundamental structural modifications to the network.

  7. Recent intensified impact of December Arctic Oscillation on subsequent January temperature in Eurasia and North Africa

    Science.gov (United States)

    He, Shengping; Wang, Huijun; Gao, Yongqi; Li, Fei

    2018-03-01

    This study reveals an intensified influence of December Arctic Oscillation (AO) on the subsequent January surface air temperature (SAT) over Eurasia and North Africa in recent decades. The connection is statistically insignificant during 1957/58-1979/80 (P1), which becomes statistically significant during 1989/90-2011/12 (P2). The possible causes are further investigated. Associated with positive December AO during P2, significant anomalous anticyclone emerges over the central North Atlantic, which is accompanied with significant westerly and easterly anomalies along 45°-65°N and 20°-40°N, respectively. This favors the significant influence of December AO on the subsequent January SAT and atmospheric circulation over Eurasia and North Africa via triggering the North Atlantic tripole sea surface temperature (SST) anomaly that persists into the subsequent January. By contrast, the December AO-related anomalous anticyclone during P1 is weak and is characterized by two separate centers located in the eastern and western North Atlantic. Correspondingly, the westerly and easterly anomalies over the North Atlantic Ocean are weak and the-related tripole SST anomaly is not well formed, unfavorable for the persistent impact of the December AO into the subsequent January. Further analyses indicate that the different anomalous anticyclone associated with the December AO over the North Atlantic may be induced by the strengthened synoptic-scale eddy feedbacks over the North Atlantic, which may be related to the interdecadal intensification of the storm track activity. Additionally, the planetary stationary wave related to the December AO propagates from surface into upper stratosphere at mid-latitudes during P2, which further propagates downward to the troposphere and causes anomalous atmospheric circulation in the subsequent January.

  8. Exogenous Acrolein intensifies sensory hypersensitivity after spinal cord injury in rat.

    Science.gov (United States)

    Butler, Breanne; Acosta, Glen; Shi, Riyi

    2017-08-15

    Acrolein, an α,β-unsaturated aldehyde associated with oxidative stress, is also a major toxic component of tobacco cigarette smoke, which has been reported in the clinic to coincide with the exacerbation of neuropathic pain after SCI. Previous reports have shown that acrolein involvement in spinal cord injury (SCI) is crucial to the development and persistence of neuropathic pain. Through the activation and upregulation of the transient receptor protein ankyrin-1 (TRPA1) cation channel, acrolein is capable of sensitizing the central nervous system in the acute and chronic stages of SCI. Here, we report that the acute or delayed nasal exposure of acrolein, apart from cigarette smoke but at concentrations similar to that found in cigarette smoke, resulted in increased neuropathic pain behaviors in a rat model of contusion SCI. We also found that this hyperalgesia occurred concurrently with an augmentation in systemic acrolein, detected by an acrolein-glutathione metabolite in the urine. The application of an acrolein scavenger, phenelzine, was shown to reduce the hyperalgesic effect of acrolein inhalation. The previously determined ability of acrolein to bind to and activate the TRPA1 channel and elicit algesic responses may be a mechanism of the phenomenon seen in this study. Upon the exposure to actual cigarette smoke after SCI, intensified neuropathic pain behaviors were also observed and persisted for at least 1week after the cessation of the exposure period. Taken together, these results indicate that cigarette smoke, through mechanisms involving acrolein, poses a threat to the vulnerable CNS after SCI and can contribute to neuropathic pain. This investigation also provides further evidence for the potential utility of acrolein scavengers as a therapeutic strategy in SCI-resultant neuropathic pain. Copyright © 2017. Published by Elsevier B.V.

  9. Continuous, but not intermittent, antipsychotic drug delivery intensifies the pursuit of reward cues.

    Science.gov (United States)

    Bédard, Anne-Marie; Maheux, Jérôme; Lévesque, Daniel; Samaha, Anne-Noël

    2011-05-01

    Chronic exposure to antipsychotic medications can persistently change brain dopamine systems. Most studies on the functional significance of these neural changes have focused on motor behavior and few have addressed how long-term antipsychotic treatment might influence dopamine-mediated reward function. We asked, therefore, whether a clinically relevant antipsychotic treatment regimen would alter the incentive motivational properties of a reward cue. We assessed the ability of a Pavlovian-conditioned stimulus to function as a conditioned reward, as well as to elicit approach behavior in rats treated with haloperidol, either continuously (achieved via subcutaneous osmotic minipump) or intermittently (achieved via daily subcutaneous injections). Continuous, but not intermittent, treatment enhanced the ability of amphetamine to potentiate the conditioned reinforcing effects of a cue associated with water. This effect was not related to differences in the ability to attribute predictive value to a conditioned stimulus (as measured by conditioned approach behavior), but was potentially linked to the development of behavioral supersensitivity to amphetamine and to augmented amphetamine-induced immediate early-gene expression (c-fos and Nur77) in dorsal striatopallidal and striatonigral cells. By enhancing the ability of reward cues to control behavior and by intensifying dopamine-mediated striatopallidal and striatonigral cell activity, standard (ie, continuous) antipsychotic treatment regimens might exacerbate drug-seeking and drug-taking behavior in schizophrenia. Achieving regular but transiently high antipsychotic levels in the brain (as modeled in the intermittent condition) might be a viable option to prevent these changes. This possibility should be explored in the clinic.

  10. Maternal high-fat diet intensifies the metabolic response to stress in male rat offspring.

    Science.gov (United States)

    Karbaschi, Roxana; Zardooz, Homeira; Khodagholi, Fariba; Dargahi, Leila; Salimi, Mina; Rashidi, FatemehSadat

    2017-01-01

    The mother's consumption of high-fat food can affect glucose metabolism and the hypothalamic-pituitary-adrenal axis responsiveness in the offspring and potentially affect the metabolic responses to stress as well. This study examines the effect of maternal high-fat diet on the expression of pancreatic glucose transporter 2 and the secretion of insulin in response to stress in offspring. Female rats were randomly divided into normal and high-fat diet groups and were fed in accordance with their given diets from pre-pregnancy to the end of lactation. The offspring were divided into control (NC and HFC) and stress (NS and HFS) groups based on their mothers' diet and exposure to stress in adulthood. After the two-week stress induction period was over, an intraperitoneal glucose tolerance test (IPGTT) was performed and plasma glucose and insulin levels were assessed. The pancreas was then removed for measuring insulin secretion from the isolated islets as well as glucose transporter 2 mRNA expression and protein levels. According to the results obtained, plasma corticosterone concentrations increased significantly on days 1 and 14 of the stress induction period and were lower on the last day compared to on the first day. In both the NS and HFS groups, stress reduced plasma insulin concentration in the IPGTT without changing the plasma glucose concentration, suggesting an increased insulin sensitivity in the NS and HFS groups, although more markedly in the latter. Stress reduced insulin secretion (at high glucose concentrations) and increased glucose transporter 2 mRNA and protein expression, especially in the HFS group. Mothers' high-fat diet appears to intensify the stress response by changing the programming of the neuroendocrine system in the offspring.

  11. Is climate change intensifying the drying-trend in the Caribbean?

    Science.gov (United States)

    Herrera, D. A.; Ault, T.; Fasullo, J.; Carrillo, C. M.

    2017-12-01

    Since 1950, the Caribbean (11ºN-25ºN; 85ºW-60ºW) has seen a significant drying trend characterized by several recent droughts, some of them contemporaneous with El Niño events. Moreover, the most recent drought from 2013 to 2016 was both the most severe and widespread event since at least 1950, and was associated with high temperatures, likely driven in part by climate change. This work examines the role of increased evaporative demand resulting from warmer temperatures on the drying trend observed in the Caribbean since 1950, using observations and model simulations. Large-scale dynamics associated with drought are also analyzed using sea surface temperature, geopotential height, wind, and precipitation anomalies, as well as radiative fluxes anomalies. Furthermore, land surface model soil moisture and high-resolution self-calibrated Palmer Drought Severity Index (scPDSI) datasets are used to quantify drought severity at local scales. The anthropogenic contribution to drought severity is estimated as the difference between the scPDSI calculated using linearly-detrended temperatures, and the scPDSI computed with the observed trend, with unadjusted precipitation, net radiation, and wind speed. Soil moisture anomalies driven by climate change are derived by comparing a large ensemble of forced simulations against a pre-industrial control. The resulting analysis indicates that anthropogenic forcing has intensified the drying trend in the Caribbean by -0.4 scPDSI-units over 60 years, and has increased the dry-land area by 10%. These findings are consistent with observed potential evapotranspiration (PET) anomalies, which are 30% higher than PET-anomalies estimated using detrended temperatures. These results suggest that climate change is already increasing the risk of drought in the Caribbean by enhancing the atmospheric demand of moisture through temperature, and provide insights into the role of climate change in future drought risk in the region.

  12. Digital radiography

    DEFF Research Database (Denmark)

    Precht, H; Gerke, O; Rosendahl, K

    2012-01-01

    BACKGROUND: New developments in processing of digital radiographs (DR), including multi-frequency processing (MFP), allow optimization of image quality and radiation dose. This is particularly promising in children as they are believed to be more sensitive to ionizing radiation than adults....... OBJECTIVE: To examine whether the use of MFP software reduces the radiation dose without compromising quality at DR of the femur in 5-year-old-equivalent anthropomorphic and technical phantoms. MATERIALS AND METHODS: A total of 110 images of an anthropomorphic phantom were imaged on a DR system (Canon DR...... with CXDI-50 C detector and MLT[S] software) and analyzed by three pediatric radiologists using Visual Grading Analysis. In addition, 3,500 images taken of a technical contrast-detail phantom (CDRAD 2.0) provide an objective image-quality assessment. RESULTS: Optimal image-quality was maintained at a dose...

  13. Fokus: Digital

    DEFF Research Database (Denmark)

    2014-01-01

    i det digitale domæne – udviklinger, der foregår hastigt og er gennemgribende, og som derfor kræver et nærmere blik på forholdet mellem kunsten og teknologien. Komponistens forståelse af sin metier udfordres – samtidig med at befæstede ideer om kunstværket møder modstand fra nye mediemæssige...... sammenhænge og fra forandrede distributionsformer. Dette betyder ændrede betingelser for både produktion og reception af kunstmusik og lydkunst. Med Digital tager vi udgangspunkt i fire komponisters meget forskellige bud på hvordan teknologien spiller en rolle i arbejdet. Juliana Hodkinson beskriver hvordan...

  14. Digital work in a digitally challenged organization

    NARCIS (Netherlands)

    Davison, R.M.; Ou, Carol

    Digitally literate employees are accustomed to having free access to digital media technologies. However, some organizations enact information technology (IT) governance structures that explicitly proscribe access to these technologies, resulting in considerable tension between employees and the

  15. USNA DIGITAL FORENSICS LAB

    Data.gov (United States)

    Federal Laboratory Consortium — To enable Digital Forensics and Computer Security research and educational opportunities across majors and departments. Lab MissionEstablish and maintain a Digital...

  16. Measurement and monitoring of entrance exposure dose rate in X-ray image intensifier television with dose rate control

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J [Bezirkskrankenhaus Brandenburg (German Democratic Republic)

    1981-03-01

    For X-ray image intensifier television operation very low entrance dose rates (about 5.2 nA/kg) are stated and demanded, respectively. These required values are often manifold exceeded in practice so that a check seems to be necessary. It is shown and proved how these measurements can be performed with simple, generally available means of measurement in the radiological practice. For ZnCdS-image intensifiers should be considered that about 13 nA/kg for the large entrance size are not to be exceeded; for the CsI type lower values (factor 1.5) are practicable because of the twofold quantum absorption efficiency. Furthermore, some tests for a semiquantitative function check of the automatic dose rate control are proposed.

  17. Can We Teach Digital Natives Digital Literacy?

    Science.gov (United States)

    Ng, Wan

    2012-01-01

    In recent years, there has been much debate about the concept of digital natives, in particular the differences between the digital natives' knowledge and adoption of digital technologies in informal versus formal educational contexts. This paper investigates the knowledge about educational technologies of a group of undergraduate students…

  18. The effects of intensified training on resting metabolic rate (RMR), body composition and performance in trained cyclists

    Science.gov (United States)

    Lundy, Bronwen; Rogers, Margot A.; Welvaert, Marijke; Halson, Shona; McKune, Andrew

    2018-01-01

    Background Recent research has demonstrated decreases in resting metabolic rate (RMR), body composition and performance following a period of intensified training in elite athletes, however the underlying mechanisms of change remain unclear. Therefore, the aim of the present study was to investigate how an intensified training period, designed to elicit overreaching, affects RMR, body composition, and performance in trained endurance athletes, and to elucidate underlying mechanisms. Method Thirteen (n = 13) trained male cyclists completed a six-week training program consisting of a “Baseline” week (100% of regular training load), a “Build” week (~120% of Baseline load), two “Loading” weeks (~140, 150% of Baseline load, respectively) and two “Recovery” weeks (~80% of Baseline load). Training comprised of a combination of laboratory based interval sessions and on-road cycling. RMR, body composition, energy intake, appetite, heart rate variability (HRV), cycling performance, biochemical markers and mood responses were assessed at multiple time points throughout the six-week period. Data were analysed using a linear mixed modeling approach. Results The intensified training period elicited significant decreases in RMR (F(5,123.36) = 12.0947, p = HRV (F(2,22.608) = 6.5212, p = 0.005); all of which improved following a period of recovery. A state of overreaching was induced, as identified by a reduction in anaerobic performance (F(5,121.87) = 8.2622, p = HRV during intensified training periods may alleviate fatigue and attenuate the observed decrease in RMR, providing more optimal conditions for a positive training adaptation. PMID:29444097

  19. An Analysis of the Observed Low-level Structure of Rapidly Intensifying and Mature Hurricane Earl (2010)

    Science.gov (United States)

    2014-01-01

    structure. J. Atmos. Sci. 49: 919–942. Marks FD, Black PG, Montgomery MT, Burpee RW. 2008. Structure of the eye and eyewall of hurricane Hugo (1989...structure of rapidly intensifying and mature hurricane Earl (2010) Michael T. Montgomery,a* Jun A. Zhangb and Roger K. Smithc aDepartment of Meteorology...Naval Postgraduate School, Monterey, CA, USA bNOAA Hurricane Research Division, Miami, FL, USA cMeteorological Institute, Ludwig Maximilians, University

  20. Dynamic imaging with a triggered and intensified CCD camera system in a high-intensity neutron beam

    International Nuclear Information System (INIS)

    Vontobel, P.; Frei, G.; Brunner, J.; Gildemeister, A.E.; Engelhardt, M.

    2005-01-01

    When time-dependent processes within metallic structures should be inspected and visualized, neutrons are well suited due to their high penetration through Al, Ag, Ti or even steel. Then it becomes possible to inspect the propagation, distribution and evaporation of organic liquids as lubricants, fuel or water. The principle set-up of a suited real-time system was implemented and tested at the radiography facility NEUTRA of PSI. The highest beam intensity there is 2x10 7 cm -2 s -1 , which enables to observe sequences in a reasonable time and quality. The heart of the detection system is the MCP intensified CCD camera PI-Max with a Peltier cooled chip (1300x1340 pixels). The intensifier was used for both gating and image enhancement, where as the information was accumulated over many single frames on the chip before readout. Although, a 16-bit dynamic range is advertised by the camera manufacturers, it must be less due to the inherent noise level from the intensifier. The obtained result should be seen as the starting point to go ahead to fit the different requirements of car producers in respect to fuel injection, lubricant distribution, mechanical stability and operation control. Similar inspections will be possible for all devices with repetitive operation principle. Here, we report about two measurements dealing with the lubricant distribution in a running motorcycle motor turning at 1200rpm. We were monitoring the periodic stationary movements of piston, valves and camshaft with a micro-channel plate intensified CCD camera system (PI-Max 1300RB, Princeton Instruments) triggered at exactly chosen time points

  1. Quantification of image persistence in a digital angiography system

    International Nuclear Information System (INIS)

    Okkalides, D.P.; Raptou, P.D.

    1993-01-01

    Image persistence, as a characteristic of video imaging systems affecting the quality of fast moving fluoroscopic images, is shown to vary considerably. A simple quantitative method for measuring image persistence in a digital angiography system is presented, together with a series of image intensifier exposure-response curves. For the Saticon tube, used with the Siemens 3VA Digitron, it was found that persistence increased for low exposure rates and may increase to 31% at a 120 ms interval. In addition, a sharp increase in image persistence, from 8.3% to 33%, was observed within 18 months from installation of the system. (author)

  2. [Intensified rehabilitation aftercare (IRENA): utilization alongside work and changes in work-related parameters].

    Science.gov (United States)

    Lamprecht, J; Behrens, J; Mau, W; Schubert, M

    2011-06-01

    An aftercare programme following medical rehabilitation may be beneficial in order to reinforce and stabilize the positive effects of rehabilitation and to encourage individual health-related modifications of behaviour and lifestyle. Medical rehabilitation and the aftercare programme of the German Pension Insurance Fund primarily are intended to sustain earning capacity. As part of an evaluation of the Intensified Rehabilitation Aftercare Programme (IRENA) established by the German Pension Insurance Fund, work-related aspects in orthopaedic patients were analyzed based on various data sources. Firstly, the significance of institutional and individual conditions for utilization of IRENA alongside work was of interest. Secondly, the IRENA participants' judgements of the changes of work-related parameters due to the programme were examined, differentiating specifically by extent of earning capacity impairments as well as by particular work problems. The data set used for the analysis is composed of person-related routine data of the German Pension Insurance Fund relative to IRENA records of the year 2007 (n=30 663), interview data from orthopaedic rehabilitation centres providing IRENA (n=225), and questionnaires of IRENA participants (n=750) that were either collected during a broad evaluation of the IRENA programme or provided by the German Pension Insurance Fund. The results show that the compatibility of IRENA and work is facilitated by the institutional conditions. However, differences between inpatient and outpatient settings have to be recognized. The possibilities to participate in IRENA throughout the day frequently are more diverse in an outpatient setting. In contrast to inpatient centres, outpatient rehabilitation centres see clearly better chances for patients to return to work and to participate in IRENA alongside. With respect to the work-related parameters (work ability, periods of sick leave), clear improvements were reported by participants from

  3. Do biomass burning aerosols intensify drought in equatorial Asia during El Niño?

    Directory of Open Access Journals (Sweden)

    M. G. Tosca

    2010-04-01

    in the region intensifies drought stress during El Niño.

  4. Do biomass burning aerosols intensify drought in equatorial Asia during El Niño?

    Energy Technology Data Exchange (ETDEWEB)

    Tosca, M G; Randerson, J; Zender, C S; Flanner, M G; Rasch, Philip J

    2010-04-16

    intensifies drought stress during El Niño.

  5. Digital produktion

    DEFF Research Database (Denmark)

    Bogen sætter fokus på digital produktion, som er en stærk læringsform, der faciliterer elevernes læreprocesser og kvalificerer elevernes faglige læringsresultater. Det sker når lærerne udarbejder didaktiske rammedesign, hvor eleverne arbejder selvstændigt inden for dette rammedesign, og hvor mål og...... procesevaluering stilladserer elevernes faglige proces. I digitale produktionsprocesser arbejder eleverne iterativt, de udvikler ejerskab til produktionen og fastholder selv deres læreprocesser. It’s multimodalitet, elevernes kollaborative tilgange, videndeling mellem eleverne og elevernes uformelle lege- og...... elevernes digitale produktion er lærernes didaktiske rammesætning og stilladserende tilgange. Her lægger lærerne op til, at eleverne som didaktiske designere i relation til rammesætningen skal organisere og planlægge deres læreprocesser, inddrages i målsætning, evaluering og valg af digitale ressourcer...

  6. Digital dannelse

    DEFF Research Database (Denmark)

    Bundsgaard, Jeppe

    2012-01-01

    I al vores iver efter at få presset nogle flere digitale dimser ind i skolen, er vi i fare for at glemme hvad det er vi skal med disse dimser. Der er store forventninger til at de kan gøre det lettere at være lærer (og dermed billigere), og det kan det måske. Men der er jo også et dannelsesspørgs......I al vores iver efter at få presset nogle flere digitale dimser ind i skolen, er vi i fare for at glemme hvad det er vi skal med disse dimser. Der er store forventninger til at de kan gøre det lettere at være lærer (og dermed billigere), og det kan det måske. Men der er jo også et...... dannelsesspørgsmål knyttet til it. Hvad er egentlig digital dannelse? Og hvad betyder det for danskfaget?...

  7. Digital forensics digital evidence in criminal investigations

    CERN Document Server

    Marshall, Angus McKenzie

    2009-01-01

    The vast majority of modern criminal investigations involve some element of digital evidence, from mobile phones, computers, CCTV and other devices. Digital Forensics: Digital Evidence in Criminal Investigations provides the reader with a better understanding of how digital evidence complements "traditional" scientific evidence and examines how it can be used more effectively and efficiently in a range of investigations. Taking a new approach to the topic, this book presents digital evidence as an adjunct to other types of evidence and discusses how it can be deployed effectively in s

  8. Digital platforms as enablers for digital transformation

    DEFF Research Database (Denmark)

    Hossain, Mokter; Lassen, Astrid Heidemann

    transformation is crucial. This study aims at exploring how organizations are driven towards transformation in various ways to embrace digital platforms for ideas, technologies, and knowledge. It shows the opportunities and challenges digital platforms bring in organizations. It also highlights underlying......Digital platforms offer new ways for organizations to collaborate with the external environment for ideas, technologies, and knowledge. They provide new possibilities and competence but they also bring new challenges for organizations. Understanding the role of these platforms in digital...... mechanisms and potential outcomes of various digital platforms. The contribution of the submission is valuable for scholars to understand and further explore this area. It provides insight for practitioners to capture value through digital platforms and accelerate the pace of organizations’ digital...

  9. H. Sapiens Digital: From Digital Immigrants and Digital Natives to Digital Wisdom

    Science.gov (United States)

    Prensky, Marc

    2009-01-01

    As we move further into the 21st century, the digital native/digital immigrant paradigm created by Marc Prensky in 2001 is becoming less relevant. In this article, Prensky suggests that we should focus instead on the development of what he calls "digital wisdom." Arguing that digital technology can make us not just smarter but truly wiser, Prensky…

  10. Dual beam vidicon digitizer

    International Nuclear Information System (INIS)

    Evans, T.L.

    1976-01-01

    A vidicon waveform digitizer which can simultaneously digitize two independent signals has been developed. Either transient or repetitive waveforms can be digitized with this system. A dual beam oscilloscope is used as the signal input device. The light from the oscilloscope traces is optically coupled to a television camera, where the signals are temporarily stored prior to digitizing

  11. Enabling Digital Literacy

    DEFF Research Database (Denmark)

    Ryberg, Thomas; Georgsen, Marianne

    2010-01-01

    There are some tensions between high-level policy definitions of “digital literacy” and actual teaching practice. We need to find workable definitions of digital literacy; obtain a better understanding of what digital literacy might look like in practice; and identify pedagogical approaches, which...... support teachers in designing digital literacy learning. We suggest that frameworks such as Problem Based Learning (PBL) are approaches that enable digital literacy learning because they provide good settings for engaging with digital literacy. We illustrate this through analysis of a case. Furthermore......, these operate on a meso-level mediating between high-level concepts of digital literacy and classroom practice....

  12. Progress in digital radiography

    International Nuclear Information System (INIS)

    Cappelle, A.

    2016-01-01

    Because of its practical aspect digital radiography is more and more used in the industrial sector. There are 2 kinds of digital radiography. First, the 'computed radiography' that uses a photon-stimulated screen, and after radiation exposure this screen must be read by an analyser to get a digit image. The second type is the 'direct radiography' that allows one to get a digit radiograph of the object directly. Digital radiography uses the same radioactive nuclides as radiography with silver films: cobalt, iridium or selenium. The spatial resolution of digital radiography is less good than with classical silver film radiography but digital radiography offers a better visual contrast. (A.C.)

  13. Digital Sensor Technology

    Energy Technology Data Exchange (ETDEWEB)

    Ted Quinn; Jerry Mauck; Richard Bockhorst; Ken Thomas

    2013-07-01

    The nuclear industry has been slow to incorporate digital sensor technology into nuclear plant designs due to concerns with digital qualification issues. However, the benefits of digital sensor technology for nuclear plant instrumentation are substantial in terms of accuracy, reliability, availability, and maintainability. This report demonstrates these benefits in direct comparisons of digital and analog sensor applications. It also addresses the qualification issues that must be addressed in the application of digital sensor technology.

  14. Digital preservation for heritages

    CERN Document Server

    Lu, Dongming

    2011-01-01

    ""Digital Preservation for Heritages: Technologies and Applications"" provides a comprehensive and up-to-date coverage of digital technologies in the area of cultural heritage preservation, including digitalization, research aiding, conservation aiding, digital exhibition, and digital utilization. Processes, technical frameworks, key technologies, as well as typical systems and applications are discussed in the book. It is intended for researchers and students in the fields of computer science and technology, museology, and archaeology. Dr. Dongming Lu is a professor at College of Computer Sci

  15. [Can implementation of intensified perinatal survey be effective in improving the quality of perinatal care?].

    Science.gov (United States)

    Troszyński, Michał

    2010-01-01

    Intensive scientific research and rapid technical progress have influenced the rapid fall in term newborn mortality. At the same time new problems have arisen such as saving the lives of infants with low and very low birth weight. Solving these problems needs reorganization of perinatal care, better equipment, especially in reference units and in outpatient clinics, as well as more intensive staff training. to obtain information whether implementation of intensified perinatal survey of fetus and newborn mortality can improve the quality of perinatal care in Poland. Implementation of the survey based on Central Statistics Office (GUS) data, Ministry of Health MZ-29 section X Document and the author's own studies. In the year 2008 newborn with birth weight less than 2500 g, constituted 6,06% liveborn infants, newborn weighing from 1000 to 2499 g - 5%, those with weight from 500 to 999 g - 0.51% of all live born infants. These figures differ according to voivodeship. The intensive survey concerning birth weight and perinatal mortality indeces in voivodeshipPoland, as well as in individual voivodeships, showed differences between data from the Central Statistics Office and data from the Ministry of Health MZ-29 document. This may be due to different methods of registrating newborn deaths eg. newborns transfered in the first weekoflife from the maternity ward to intensive care neonatal ward or to other specialistic departaments. Another reason for the difference may be discharge of the newborn data according to the place of birth or the mother's place of permanent domicile registration. This causes disturbances in flow of infomation resulting in ineffective analysis of perinatal mortality and of perinatal care evaluation. In the ongoing analysis it was found that in Poland stillbirths occur twice as often as perinatal deaths (4.3 per thousands) stillbirths and 2.15 per thousands perinatal deaths), with significant differences between voivodeships. This makes it

  16. Cognitive Hacking and Digital Government: Digital Identity

    OpenAIRE

    Paul Thompson

    2004-01-01

    Recently the National Center for Digital Government held a workshop on "The Virtual Citizen: Identity, Autonomy, and Accountability: A Civic Scenario Exploration of the Role of Identity in On-Line. Discussions at the workshop focused on five scenarios for future authentication policies with respect to digital identity. The underlying technologies considered for authentication were: biometrics: cryptography, with a focus on digital signatures; secure processing/computation; and reputation syst...

  17. Digital Materialisms: Frameworks for Digital Media Studies

    OpenAIRE

    Casemajor, Nathalie

    2015-01-01

    Since the 1980s, digital materialism has received increasing interest in the field of media studies. Materialism as a theoretical paradigm assumes that all things in the world are tied to physical processes and matter. Yet within digital media studies, the understanding of what should be the core object of a materialist analysis is debated. This paper proposes to untangle some of the principal theoretical propositions that compose the field of digital materialism. It outlines six frameworks t...

  18. Subtracted versus non-subtracted digital imaging in peripheral angiography

    International Nuclear Information System (INIS)

    Fink, U.; Heywang, S.; Mayr, B.; Berger, H.

    1989-01-01

    Digital subtraction angiography (DSA) plays an important role in the management of vascular diseases of the lower extremities. A disadvantage is the lack of an automatically moving table top. We used a 1,024x1,024 matrix with a large-screen intensifier system and an automated 'stepping' facility. In 161 examinations of the arteries of the lower extremity digital peripheral arteriography was performed with and without the subtraction technique. We compared the influence of different iodine concentrations in DA and DSA. Peripheral DA proved to be equal to peripheral DSA in the region of the pelvis, thigh and knee, with no adequate contrasting being obtained merely in the region of the lower leg arteries in about 45%. It is necessary to use contrast medium at a concentration of 300 mg I/ml. The installation of an automated 'stepping' facility reduces the amount of contrast' medium needed and the exposure time. (orig.)

  19. Effects of repetitive or intensified instructions in telephone assisted, bystander cardiopulmonary resuscitation: an investigator-blinded, 4-armed, randomized, factorial simulation trial.

    Science.gov (United States)

    van Tulder, R; Roth, D; Krammel, M; Laggner, R; Heidinger, B; Kienbacher, C; Novosad, H; Chwojka, C; Havel, C; Sterz, F; Schreiber, W; Herkner, H

    2014-01-01

    Compression depth is frequently suboptimal in cardiopulmonary resuscitation (CPR). We investigated effects of intensified wording and/or repetitive target depth instructions on compression depth in telephone-assisted, protocol driven, bystander CPR on a simulation manikin. Thirty-two volunteers performed 10 min of compression only-CPR in a prospective, investigator-blinded, 4-armed, factorial setting. Participants were randomized either to standard wording ("push down firmly 5 cm"), intensified wording ("it is very important to push down 5 cm every time") or standard or intensified wording repeated every 20s. Three dispatchers were randomized to give these instructions. Primary outcome was relative compression depth (absolute compression depth minus leaning depth). Secondary outcomes were absolute distance, hands-off times as well as BORG-scale and nine-hole peg test (NHPT), pulse rate and blood pressure to reflect physical exertion. We applied a random effects linear regression model. Relative compression depth was 35 ± 10 mm (standard) versus 31 ± 11 mm (intensified wording) versus 25 ± 8 mm (repeated standard) and 31 ± 14 mm (repeated intensified wording). Adjusted for design, body mass index and female sex, intensified wording and repetition led to decreased compression depth of 13 (95%CI -25 to -1) mm (p=0.04) and 9 (95%CI -21 to 3) mm (p=0.13), respectively. Secondary outcomes regarding intensified wording showed significant differences for absolute distance (43 ± 2 versus 20 (95%CI 3-37) mm; p=0.01) and hands-off times (60 ± 40 versus 157 (95%CI 63-251) s; p=0.04). In protocol driven, telephone-assisted, bystander CPR, intensified wording and/or repetitive target depth instruction will not improve compression depth compared to the standard instruction. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. New spectrofluorometer with pulsed intensified photodiodes array for direct trace determination of actinides and lanthanides in solutions

    International Nuclear Information System (INIS)

    Decambox, P.; Kirsch, B.; Mauchien, P.; Moulin, C.

    1989-01-01

    Actinides and lanthanides in solution at very low level are determined by Time-Resolved Laser-Induced Spectrofluorometry (TRLIS) with pulsed intensified photodiodes array detection. Temporal resolution allows discrimination against short lifetime fluorescence and measurement of fluorescence lifetime in various matrices. The use of laser source leads to excitation selectivity and high sensitivity. Multichannel detection allows to cover the entire wavelength range of interest which leads to emission selectivity and rapidity. These different advantages are present in the newly commercialized spectrofluorometer FLUO 2001 together with specially analytical adapted software. The apparatus and performances obtained for several actinides and lanthanides are presented

  1. Logic of the digital

    CERN Document Server

    Evens, Aden

    2015-01-01

    Building a foundational understanding of the digital, Logic of the Digital reveals a unique digital ontology. Beginning from formal and technical characteristics, especially the binary code at the core of all digital technologies, Aden Evens traces the pathways along which the digital domain of abstract logic encounters the material, human world. How does a code using only 0s and 1s give rise to the vast range of applications and information that constitutes a great and growing portion of our world? Evens' analysis shows how any encounter between the actual and the digital must cross an ontolo

  2. Evidence of disturbed sleep and mood state in well-trained athletes during short-term intensified training with and without a high carbohydrate nutritional intervention.

    Science.gov (United States)

    Killer, S C; Svendsen, I S; Jeukendrup, A E; Gleeson, M

    2017-07-01

    Few studies have investigated the effects of exercise training on sleep physiology in well-trained athletes. We investigated changes in sleep markers, mood state and exercise performance in well-trained cyclists undergoing short-term intensified training and carbohydrate nutritional intervention. Thirteen highly-trained male cyclists (age: 25 ± 6y, [Formula: see text]O 2max : 72 ± 5 ml/kg/min) participated in two 9-day periods of intensified training while undergoing a high (HCHO) or moderate (CON) carbohydrate nutritional intervention before, during and after training sessions. Sleep was measured each night via wristwatch actigraphy. Mood state questionnaires were completed daily. Performance was assessed with maximal oxygen uptake ([Formula: see text]. Percentage sleep time fell during intensified training (87.9 ± 1.5 to 82.5 ± 2.3%; p Sleep efficiency decreased during intensified training (83.1 ± 5.3 to 77.8 ± 8.6%; p sleep time was significantly higher in CON than HCHO throughout intensified training. Mood disturbance increased during intensified training and was higher in CON than HCHO (p sleep quality, mood state and maximal exercise performance.

  3. Digital TV-echelle spectrograph for simultaneous multielemental analysis using microcomputer control

    International Nuclear Information System (INIS)

    Davidson, J.B.; Case, A.L.

    1980-12-01

    A digital TV-echelle spectrograph with microcomputer control was developed for simultaneous multielemental analysis. The optical system is a commercially available unit originally equipped for film and photomultiplier (single element) readout. The film port was adapted for the intensifier camera. The camera output is digitized and stored in a microcomputer-controlled, 512 x 512 x 12 bit memory and image processor. Multiple spectra over the range of 200 to 800 nm are recorded in a single exposure. Spectra lasting from nanoseconds to seconds are digitized and stored in 0.033 s and displayed on a TV monitor. An inexpensive microcomputer controls the exposure, reads and displays the intensity of predetermined spectral lines, and calculates wavelengths of unknown lines. The digital addresses of unknown lines are determined by superimposing a cursor on the TV display. The microcomputer also writes into memory wavelength fiducial marks for alignment of the TV camera

  4. Blood flow determinations utilizing digital densitometry

    International Nuclear Information System (INIS)

    Lois, F.; Mankovich, N.J.; Gomes, A.S.

    1987-01-01

    A method of obtaining relative and absolute blood flow measurements from digital densitometry was evaluated with a simulated vessel phantom and a hydrodynamic model. A digital vascular imaging system capable of acquisition in 512 2 and 1024 2 mode was used. Relative and absolute blood flow were measured using parameters derived from the densitometric curve. Since application of densitometric data to absolute flow measurements requires the vessel diameter, an algorithm for vessel size determination was created. Gray scale changes were demonstrated to be linearly related to contrast concentration. The variance of vessel size determination was significantly different in all combinations of 1024 2 and 512 2 imaging with 15 cm or 35 cm field size. The error in vessel size determination was significantly less using the larger 1024 2 matrix and the smaller 15 cm image intensifier field size, as shown by the smaller variance. In relative flow determinations, there was good correlation between the flow and four parameters of the densitometric curve with no significant differences between 512 2 and 1024 2 imaging. Absolute flow determinations had slightly lower correlation to actual flow but were not significantly different from relative flow determinations. Relative and absolute blood flow determinations can be performed adequately with either 512 2 or 1024 2 imaging. The increased accuracy in vessel size determination with 1024 2 imaging makes this high resolution system potentially perferable to determine absolute blood flow. (orig.)

  5. Developments in digital radiography: an equipment update

    International Nuclear Information System (INIS)

    James, J.J.; O'Connor, P.J.; Davies, A.G.; Cowen, A.R.

    2001-01-01

    Digital X-ray imaging technology has advanced rapidly over the past few years. This review, particularly aimed at those involved in using and purchasing such technology, is an attempt to unravel some of the complexities of this potentially confusing subject. The main groups of X-ray imaging devices that are considered are digitisers of conventional radiographs, image-intensifier-based fluorography systems, photostimulable phosphor computed radiography, amorphous selenium-based technology for thorax imaging and flat-panel systems. As well as describing these different systems, we look at ways of objectively assessing their image quality. Concepts that are used and explained include spatial resolution, grey-scale bit resolution, signal-to-noise ratio and detective quantum efficiency. An understanding of these basic parameters is vital in making a scientific assessment of a system's performance. Image processing and techniques are also briefly discussed, particularly with reference to their potential effects on image quality. This review aims to provide a basic understanding of digital X-ray imaging technology and enables the reader to make an independent and educated assessment of the relative merits of each system. (orig.)

  6. Elevated Serum Hepcidin Levels during an Intensified Training Period in Well-Trained Female Long-Distance Runners

    Directory of Open Access Journals (Sweden)

    Aya Ishibashi

    2017-03-01

    Full Text Available Iron is essential for providing oxygen to working muscles during exercise, and iron deficiency leads to decreased exercise capacity during endurance events. However, the mechanism of iron deficiency among endurance athletes remains unclear. In this study, we compared iron status between two periods involving different training regimens. Sixteen female long-distance runners participated. Over a seven-month period, fasting blood samples were collected during their regular training period (LOW; middle of February and during an intensified training period (INT; late of August to determine blood hematological, iron, and inflammatory parameters. Three-day food diaries were also assessed. Body weight and lean body mass did not differ significantly between LOW and INT, while body fat and body fat percentage were significantly lower in INT (p < 0.05. Blood hemoglobin, serum ferritin, total protein, and iron levels, total iron-binding capacity, and transferrin saturation did not differ significantly between the two periods. Serum hepcidin levels were significantly higher during INT than LOW (p < 0.05. Carbohydrate and iron intakes from the daily diet were significantly higher during INT than LOW (p < 0.05. In conclusion, an elevated hepcidin level was observed during an intensified training period in long-distance runners, despite an apparently adequate daily intake of iron.

  7. Impacts of aeration management and polylactic acid addition on dissolved organic matter characteristics in intensified aquaponic systems.

    Science.gov (United States)

    Wu, Haiming; Zou, Yina; Lv, Jialong; Hu, Zhen

    2018-08-01

    Aquaponics as a potential alternative for conventional aquaculture industry has increasingly attracted worldwide attention in recent years. However, the sustainable application of aquaponics is facing a growing challenge. In particular, there is a pressing need to better understand and control the accumulation of dissolved organic matter (DOM) in aquaponics with the aim of optimizing nitrogen utilization efficiency. This study was aiming for assessing the characteristics of DOM in the culture water and the relationship with the nitrogen transformations in different intensified aquaponic systems with hydroponic aeration supplement and polylactic acid (PLA) addition. Two enhancing attempts altered the quantity of DOM in aquaponic systems significantly with a varying DOM content of 21.98-45.65 mg/L. The DOM could be represented by four identified fluorescence components including three humic -like materials (83-86%) and one tryptophan-like substance (14-17%). The fluorescence intensities of humic acid-like components were decreased significantly after the application of intensifying strategies, which indicating that two enhancing attempts possibly affected humic acid-like fluorescence. Variation of optical indices also suggested the reductions of water DOM which could be impacted by the enhancing nitrogen treatment processes. These findings will benefit the potential applications and sustainable operation of these strategies in aquaponics. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Therapeutic inertia and intensified treatment in diabetes mellitus prescription patterns: A nationwide population-based study in Taiwan.

    Science.gov (United States)

    Huang, Li-Ying; Yeh, Hseng-Long; Yang, Ming-Chin; Shau, Wen-Yi; Su, Syi; Lai, Mei-Shu

    2016-12-01

    Objective To measure therapeutic inertia by characterizing prescription patterns using secondary data obtained from the nationwide diabetes mellitus pay-for-performance (DM-P4P) programme in Taiwan. Methods Using reimbursement claims from Taiwan's National Health Insurance Research Database, a nationwide retrospective cohort study was undertaken of patients with diabetes mellitus who participated in the DM-P4P programme from 2006-2008. Glycosylated haemoglobin results were used to evaluate modifications in therapy in response to poor diabetes control. Prescription patterns were used to assign patients to either a therapeutic inertia group or an intensified treatment group. Therapeutic inertia was defined as the failure to act on a known problem. Results The research sample comprised of 168 876 patients with diabetes mellitus who had undergone 899 135 tests. Of these, 37.4% (336 615 visits) of prescriptions were for a combination of two types of drug and 27.7% (248 788 visits) were for a combination of three types of drug. The proportion of patients in the intensified therapy group who were prescribed more than two types of drug was considerably higher than that in the therapeutic inertia group. Conclusion In many cases in the therapeutic inertia group only a single type of hypoglycaemic drug was prescribed or the dosage remained unchanged.

  9. Sensitometric effects of varying the intensifying screens used with Agfa Dentus ST8G and RP6 panoramic radiographic films.

    Science.gov (United States)

    Wakoh, M; Farman, A G; Scarfe, W C; Kitagawa, H; Kuroyanagi, K

    1997-07-01

    To compare the sensitometric effects and information yield of varying the intensifying screens used with both Dentus ST8G and RP6 Agfa Gevaert, Dormagen, Germany panoramic radiographic films. Four screen-film combinations were employed for each of the two film types. The screens used were blue fluorescing PX-III (Kasei Optonix, Tokyo, Japan) and Special (Siemens AG, Bensheim, Germany), as well as green fluorescing Lanex Regular (Eastman Kodak, Rochester, NY, USA) and Trimax T16 (3M, Mineapolis, Minnesota, USA). The density response for each screen-film combination was evaluated using the characteristic curves generated. Information yield, as determined by the radiographic detection of defects in an aluminium test object, was evaluated by nine observers. The characteristic curves for ST8G were different when green and blue fluorescing screens were used; however, those for RP6 varied little irrespective of the choice of intensifying screens. Observers were able to perceive defects at significantly lower radiation exposures for ST8G combined with green fluorescing screens compared with blue emitting screens. RP6 with all screen combinations provided similar image detail perceptibility at comparable exposures with ST8G with green-fluorescing screens. RP6 is suitable for use with either the spectrally matched blue emitting screens or green-emitting screens. ST8G radiographic film should always be matched to rare earth screens.

  10. Coastal California Digital Imagery

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This digital ortho-imagery dataset is a survey of coastal California. The project area consists of approximately 3774 square miles. The project design of the digital...

  11. Digital rectal exam

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007069.htm Digital rectal exam To use the sharing features on this page, please enable JavaScript. A digital rectal exam is an examination of the lower ...

  12. Digital dannelse til gymnasieeleverne

    DEFF Research Database (Denmark)

    Kaarsted, Thomas; Holch Andersen, Knud

    2012-01-01

    Søsætningen af en ny tænketank skal udstikke nye digital retningslinjer for gymnasiekolerne. Baggrunden er en erkendelse af, at it-infrastruktur og digital teknologi ikke gør de alene.......Søsætningen af en ny tænketank skal udstikke nye digital retningslinjer for gymnasiekolerne. Baggrunden er en erkendelse af, at it-infrastruktur og digital teknologi ikke gør de alene....

  13. Basic digital signal processing

    CERN Document Server

    Lockhart, Gordon B

    1985-01-01

    Basic Digital Signal Processing describes the principles of digital signal processing and experiments with BASIC programs involving the fast Fourier theorem (FFT). The book reviews the fundamentals of the BASIC program, continuous and discrete time signals including analog signals, Fourier analysis, discrete Fourier transform, signal energy, power. The text also explains digital signal processing involving digital filters, linear time-variant systems, discrete time unit impulse, discrete-time convolution, and the alternative structure for second order infinite impulse response (IIR) sections.

  14. Digital asset management.

    Science.gov (United States)

    Humphrey, Clinton D; Tollefson, Travis T; Kriet, J David

    2010-05-01

    Facial plastic surgeons are accumulating massive digital image databases with the evolution of photodocumentation and widespread adoption of digital photography. Managing and maximizing the utility of these vast data repositories, or digital asset management (DAM), is a persistent challenge. Developing a DAM workflow that incorporates a file naming algorithm and metadata assignment will increase the utility of a surgeon's digital images. Copyright 2010 Elsevier Inc. All rights reserved.

  15. Digital Inkjet Textile Printing

    OpenAIRE

    Wang, Meichun

    2017-01-01

    Digital inkjet textile printing is an emerging technology developed with the rise of the digital world. It offers a possibility to print high-resolution images with unlimited color selection on fabrics. Digital inkjet printing brings a revolutionary chance for the textile printing industry. The history of textile printing shows the law how new technology replaces the traditional way of printing. This indicates the future of digital inkjet textile printing is relatively positive. Differen...

  16. High-frame-rate digital radiographic videography

    Science.gov (United States)

    King, Nicholas S. P.; Cverna, Frank H.; Albright, Kevin L.; Jaramillo, Steven A.; Yates, George J.; McDonald, Thomas E.; Flynn, Michael J.; Tashman, Scott

    1994-10-01

    High speed x-ray imaging can be an important tool for observing internal processes in a wide range of applications. In this paper we describe preliminary implementation of a system having the eventual goal of observing the internal dynamics of bone and joint reactions during loading. Two Los Alamos National Laboratory (LANL) gated and image intensified camera systems were used to record images from an x-ray image convertor tube to demonstrate the potential of high frame-rate digital radiographic videography in the analysis of bone and joint dynamics of the human body. Preliminary experiments were done at LANL to test the systems. Initial high frame-rate imaging (from 500 to 1000 frames/s) of a swinging pendulum mounted to the face of an X-ray image convertor tube demonstrated high contrast response and baseline sensitivity. The systems were then evaluated at the Motion Analysis Laboratory of Henry Ford Health Systems Bone and Joint Center. Imaging of a 9 inch acrylic disk with embedded lead markers rotating at approximately 1000 RPM, demonstrated the system response to a high velocity/high contrast target. By gating the P-20 phosphor image from the X-ray image convertor with a second image intensifier (II) and using a 100 microsecond wide optical gate through the second II, enough prompt light decay from the x-ray image convertor phosphor had taken place to achieve reduction of most of the motion blurring. Measurement of the marker velocity was made by using video frames acquired at 500 frames/s. The data obtained from both experiments successfully demonstrated the feasibility of the technique. Several key areas for improvement are discussed along with salient test results and experiment details.

  17. Digital Language Death

    Science.gov (United States)

    Kornai, András

    2013-01-01

    Of the approximately 7,000 languages spoken today, some 2,500 are generally considered endangered. Here we argue that this consensus figure vastly underestimates the danger of digital language death, in that less than 5% of all languages can still ascend to the digital realm. We present evidence of a massive die-off caused by the digital divide. PMID:24167559

  18. Digital language death.

    Directory of Open Access Journals (Sweden)

    András Kornai

    Full Text Available Of the approximately 7,000 languages spoken today, some 2,500 are generally considered endangered. Here we argue that this consensus figure vastly underestimates the danger of digital language death, in that less than 5% of all languages can still ascend to the digital realm. We present evidence of a massive die-off caused by the digital divide.

  19. Digital Imaging. Chapter 16

    Energy Technology Data Exchange (ETDEWEB)

    Clunie, D. [CoreLab Partners, Princeton (United States)

    2014-09-15

    The original means of recording X ray images was a photographic plate. Nowadays, all medical imaging modalities provide for digital acquisition, though globally, the use of radiographic film is still widespread. Many modalities are fundamentally digital in that they require image reconstruction from quantified digital signals, such as computed tomography (CT) and magnetic resonance imaging (MRI)

  20. Preparing collections for digitization

    CERN Document Server

    Bulow, Anna E

    2010-01-01

    Most libraries, archives and museums are confronting the challenges of providing digital access to their collections. This guide offers guidance covering the end-to-end process of digitizing collections, from selecting records for digitization to choosing suppliers and equipment and dealing with documents that present individual problems.

  1. Digital voltage discriminator

    International Nuclear Information System (INIS)

    Zhou Zhicheng

    1992-01-01

    A digital voltage discriminator is described, which is synthesized by digital comparator and ADC. The threshold is program controllable with high stability. Digital region of confusion is approximately equal to 1.5 LSB. This discriminator has a single channel analyzer function model with channel width of 1.5 LSB

  2. Playtesting the Digital Playground

    DEFF Research Database (Denmark)

    Majgaard, G.; Jessen, Carsten

    2009-01-01

    Being able to be absorbed in play in the digital playground is motivating for children who are used digital computer games. The children can play and exercise outdoors while using the same literacy as in indoor digital games. This paper presents a new playground product where an outdoor playgroun...

  3. Quantitative imaging of turbulent and reacting flows

    Energy Technology Data Exchange (ETDEWEB)

    Paul, P.H. [Sandia National Laboratories, Livermore, CA (United States)

    1993-12-01

    Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and spatial resolution in the imaging system as well as developing excitation/detection strategies which provide for a quantitative measure of particular flowfield scalars. The standard camera used for the study is an intensified CCD array operated in a conventional video format. The design of the system was based on detailed modeling of signal and image transfer properties of fast UV imaging lenses, image intensifiers and CCD detector arrays. While this system is suitable for direct scalar imaging, derived quantities (e.g. temperature or velocity images) require an exceptionally wide dynamic range imaging detector. To apply these diagnostics to reacting flows also requires a very fast shuttered camera. The authors have developed and successfully tested a new type of gated low-light level detector. This system relies on fast switching of proximity focused image-diode which is direct fiber-optic coupled to a cooled CCD array. Tests on this new detector show significant improvements in detection limit, dynamic range and spatial resolution as compared to microchannel plate intensified arrays.

  4. Digital disruption ?syndromes.

    Science.gov (United States)

    Sullivan, Clair; Staib, Andrew

    2017-05-18

    The digital transformation of hospitals in Australia is occurring rapidly in order to facilitate innovation and improve efficiency. Rapid transformation can cause temporary disruption of hospital workflows and staff as processes are adapted to the new digital workflows. The aim of this paper is to outline various types of digital disruption and some strategies for effective management. A large tertiary university hospital recently underwent a rapid, successful roll-out of an integrated electronic medical record (EMR). We observed this transformation and propose several digital disruption "syndromes" to assist with understanding and management during digital transformation: digital deceleration, digital transparency, digital hypervigilance, data discordance, digital churn and post-digital 'depression'. These 'syndromes' are defined and discussed in detail. Successful management of this temporary digital disruption is important to ensure a successful transition to a digital platform. What is known about this topic? Digital disruption is defined as the changes facilitated by digital technologies that occur at a pace and magnitude that disrupt established ways of value creation, social interactions, doing business and more generally our thinking. Increasing numbers of Australian hospitals are implementing digital solutions to replace traditional paper-based systems for patient care in order to create opportunities for improved care and efficiencies. Such large scale change has the potential to create transient disruption to workflows and staff. Managing this temporary disruption effectively is an important factor in the successful implementation of an EMR. What does this paper add? A large tertiary university hospital recently underwent a successful rapid roll-out of an integrated electronic medical record (EMR) to become Australia's largest digital hospital over a 3-week period. We observed and assisted with the management of several cultural, behavioural and

  5. Ageing and digital games

    DEFF Research Database (Denmark)

    Iversen, Sara Mosberg

    Digital games are still to a great degree considered a medium mainly for young boys. However, available statistics on Western media use show that this is far from the case. Increasingly, people of all ages and genders play digital games, also older adults in their early 60s and beyond. The aim...... of the book is to examine, analyse and discuss: 1) What older adults do with digital games and what meanings the use of digital games take on in the everyday life of older adults; 2) How older adults are perceived by society in relation to digital games; 3) How play and games can be used both...

  6. Digital Living at Home

    DEFF Research Database (Denmark)

    Andersen, Pernille Viktoria Kathja; Christiansen, Ellen Tove

    2013-01-01

    of these user voices has directed us towards a ‘home-keeping’ design discourse, which opens new horizons for design of digital home control systems by allowing users to perform as self-determined controllers and groomers of their habitat. The paper concludes by outlining the implications of a ‘home......Does living with digital technology inevitably lead to digital living? Users talking about a digital home control system, they have had in their homes for eight years, indicate that there is more to living with digital technology than a functional-operational grip on regulation. Our analysis......-keeping’ design discourse....

  7. New approaches to determine fatigue in elite athletes during intensified training: Resting metabolic rate and pacing profile.

    Directory of Open Access Journals (Sweden)

    Amy L Woods

    Full Text Available Elite rowers complete a high volume of training across a number of modalities to prepare for competition, including periods of intensified load, which may lead to fatigue and short-term performance decrements. As yet, the influence of substantial fatigue on resting metabolic rate (RMR and exercise regulation (pacing, and their subsequent utility as monitoring parameters, has not been explicitly investigated in elite endurance athletes.Ten National-level rowers completed a four-week period of intensified training. RMR, body composition and energy intake were assessed PRE and POST the four-week period using indirect calorimetry, Dual-Energy X-Ray Densitometry (DXA, and three-day food diary, respectively. On-water rowing performance and pacing strategy was evaluated from 5 km time trials. Wellness was assessed weekly using the Multicomponent Training Distress Scale (MTDS.Significant decreases in absolute (mean ± SD of difference, p-value: -466 ± 488 kJ.day-1, p = 0.01 and relative RMR (-8.0 ± 8.1 kJ.kg.FFM-1, p = 0.01 were observed. Significant reductions in body mass (-1.6 ± 1.3 kg, p = 0.003 and fat mass (-2.2 ± 1.2 kg, p = 0.0001 were detected, while energy intake was unchanged. On-water 5 km rowing performance worsened (p < 0.05 and an altered pacing strategy was evident. Fatigue and total mood disturbance significantly increased across the cycle (p < 0.05, and trends were observed for reduced vigour and increased sleep disturbance (p < 0.1.Four weeks of heavy training decreased RMR and body composition variables in elite rowers and induced substantial fatigue, likely related to an imbalance between energy intake and output. This study demonstrates that highly experienced athletes do not necessarily select the correct energy intake during periods of intensified training, and this can be assessed by reductions in RMR and body composition. The shortfall in energy availability likely affected recovery from training and altered 5 km time trial

  8. Exposure time, running and skill-related performance in international u20 rugby union players during an intensified tournament.

    Directory of Open Access Journals (Sweden)

    Christopher J Carling

    Full Text Available This study investigated exposure time, running and skill-related performance in two international u20 rugby union teams during an intensified tournament: the 2015 Junior World Rugby Championship.Both teams played 5 matches in 19 days. Analyses were conducted using global positioning system (GPS tracking (Viper 2™, Statsports Technologies Ltd and event coding (Opta Pro®.Of the 62 players monitored, 36 (57.1% participated in 4 matches and 23 (36.5% in all 5 matches while player availability for selection was 88%. Analyses of team running output (all players completing >60-min play showed that the total and peak 5-minute high metabolic load distances covered were likely-to-very likely moderately higher in the final match compared to matches 1 and 2 in back and forward players. In individual players with the highest match-play exposure (participation in >75% of total competition playing time and >75-min in each of the final 3 matches, comparisons of performance in matches 4 and 5 versus match 3 (three most important matches reported moderate-to-large decreases in total and high metabolic load distance in backs while similar magnitude reductions occurred in high-speed distance in forwards. In contrast, skill-related performance was unchanged, albeit with trivial and unclear changes, while there were no alterations in either total or high-speed running distance covered at the end of matches.These findings suggest that despite high availability for selection, players were not over-exposed to match-play during an intensified u20 international tournament. They also imply that the teams coped with the running and skill-related demands. Similarly, individual players with the highest exposure to match-play were also able to maintain skill-related performance and end-match running output (despite an overall reduction in the latter. These results support the need for player rotation and monitoring of performance, recovery and intervention strategies during

  9. Exposure time, running and skill-related performance in international u20 rugby union players during an intensified tournament

    Science.gov (United States)

    Carling, Christopher J.; Flanagan, Eamon; O’Doherty, Pearse; Piscione, Julien

    2017-01-01

    Purpose This study investigated exposure time, running and skill-related performance in two international u20 rugby union teams during an intensified tournament: the 2015 Junior World Rugby Championship. Method Both teams played 5 matches in 19 days. Analyses were conducted using global positioning system (GPS) tracking (Viper 2™, Statsports Technologies Ltd) and event coding (Opta Pro®). Results Of the 62 players monitored, 36 (57.1%) participated in 4 matches and 23 (36.5%) in all 5 matches while player availability for selection was 88%. Analyses of team running output (all players completing >60-min play) showed that the total and peak 5-minute high metabolic load distances covered were likely-to-very likely moderately higher in the final match compared to matches 1 and 2 in back and forward players. In individual players with the highest match-play exposure (participation in >75% of total competition playing time and >75-min in each of the final 3 matches), comparisons of performance in matches 4 and 5 versus match 3 (three most important matches) reported moderate-to-large decreases in total and high metabolic load distance in backs while similar magnitude reductions occurred in high-speed distance in forwards. In contrast, skill-related performance was unchanged, albeit with trivial and unclear changes, while there were no alterations in either total or high-speed running distance covered at the end of matches. Conclusions These findings suggest that despite high availability for selection, players were not over-exposed to match-play during an intensified u20 international tournament. They also imply that the teams coped with the running and skill-related demands. Similarly, individual players with the highest exposure to match-play were also able to maintain skill-related performance and end-match running output (despite an overall reduction in the latter). These results support the need for player rotation and monitoring of performance, recovery and

  10. Digital positron annihilation spectrometer

    International Nuclear Information System (INIS)

    Cheng Bin; Weng Huimin; Han Rongdian; Ye Bangjiao

    2010-01-01

    With the high speed development of digital signal process, the technique of the digitization and processing of signals was applied in the domain of a broad class of nuclear technique. The development of digital positron lifetime spectrometer (DPLS) is more promising than the conventional positron lifetime spectrometer equipped with nuclear instrument modules. And digital lifetime spectrometer has many advantages, such as low noise, long term stability, flexible online or offline digital processing, simple setup, low expense, easy to setting, and more physical information. Digital constant fraction discrimination is for timing. And a new method of optimizing energy windows setting for digital positron lifetime spectrometer is also developed employing the simulated annealing for the convenient use. The time resolution is 220ps and the count rate is 200cps. (authors)

  11. Digital Banking: Risks of Financial Digitalization

    Directory of Open Access Journals (Sweden)

    Kornіvska Valerіa O.

    2017-09-01

    Full Text Available The paper demonstrates the results of the research into development of the digital economy in the global financial space, shows the contradictions of these processes in the context of the growth of financial inclusion of households, identifies the risks of active introduction of digital banking in poor countries of the world. The characteristics of the processes of growth of the influence of banking institutions on the operational activity and daily life of households are given, and it is proved that under conditions of digital banking, without having any other alternative ways of economic activity in terms of money circulation than non-cash turnover, clients are forced to agree to unlimited presence of financial operators in social systems. It is substantiated that in Ukraine the global risk of digitalization of the society is gradually developing as a result of the creation of unified information systems for the control of global financial flows.

  12. Digital rights management for digital cinema

    Science.gov (United States)

    Kirovski, Darko; Peinado, Marcus; Petitcolas, Fabien A. P.

    2001-12-01

    There is a wide consensus among the feature film production studios that the Internet era brings a new paradigm for film distribution to cinemas worldwide. The benefits of digital cinema to both producers and cinemas are numerous: significantly lower distribution and maintenance costs, immediate access to film libraries, higher presentation quality, and strong potential for developing new business models. Despite these advantages, the studios are still reluctant to jump into the digital age. The main showstopper for digital cinema is the danger of widespread piracy. Piracy already costs Hollywood an estimated two billion dollars annually and digital cinema without proper copyright enforcement could increase this number. In this paper, we present a copyright management system that aims at providing the set of necessary security tools: standard cryptographic primitives and copyright protection mechanisms that enable a reliable and secure feature film delivery system.

  13. Digital portal radiography in mantle-field irradiation

    International Nuclear Information System (INIS)

    Scheck, R.J.; Wendt, T.; Panzer, M.

    1991-01-01

    This paper evaluates the potential of digital luminescence radiography to improve image quality of portal films in mantle-field irradiation. Conventional and digital verification films of an anthropomorphic phantom and 20 patients treated for Hodgkin disease with mantle radiation therapy were obtained with high-energy photon beams. Both conventional films and storage phosphor screens were placed into a cassette with steel intensifier screens. Exposed storage phosphor screens were processed in a semiautomatic mode, with an optimized contrast curve with moderate edge enhancement, and printed as hard copies in a double-image output format. Images were evaluated according to contrast resolution, delineation of anatomic structures, and accuracy of field alignment. Digital portal radiographs were superior to conventional ones with regard to contrast resolution. Thus, they allowed quick and easy detection of relevant structures, although delineation of anatomic structures and field alignments were judged to be equivalent with both techniques. Shorter exposure times for digital images resulted in a reduction in motion artifacts

  14. Digital Collections, Digital Libraries and the Digitization of Cultural Heritage Information.

    Science.gov (United States)

    Lynch, Clifford

    2002-01-01

    Discusses the development of digital collections and digital libraries. Topics include digitization of cultural heritage information; broadband issues; lack of compelling content; training issues; types of materials being digitized; sustainability; digital preservation; infrastructure; digital images; data mining; and future possibilities for…

  15. Elevated Serum Hepcidin Levels during an Intensified Training Period in Well-Trained Female Long-Distance Runners.

    Science.gov (United States)

    Ishibashi, Aya; Maeda, Naho; Sumi, Daichi; Goto, Kazushige

    2017-03-14

    Iron is essential for providing oxygen to working muscles during exercise, and iron deficiency leads to decreased exercise capacity during endurance events. However, the mechanism of iron deficiency among endurance athletes remains unclear. In this study, we compared iron status between two periods involving different training regimens. Sixteen female long-distance runners participated. Over a seven-month period, fasting blood samples were collected during their regular training period (LOW; middle of February) and during an intensified training period (INT; late of August) to determine blood hematological, iron, and inflammatory parameters. Three-day food diaries were also assessed. Body weight and lean body mass did not differ significantly between LOW and INT, while body fat and body fat percentage were significantly lower in INT ( p daily diet were significantly higher during INT than LOW ( p daily intake of iron.

  16. Effects of oxygen delivery, dietary nitrate, intensified training and prior exercise on oxygen uptake kinetics and performance in humans

    DEFF Research Database (Denmark)

    Christensen, Peter Møller

    benefits from supplementing with nitrate to improve exercise efficiency and performance in endurance trained subjects. Furthermore it appears difficult to improve VO2 kinetics with intensified training in trained athletes; however intense exercise can amplify the VO2 response during subsequent high......In response to an increase in the metabolic demand the oxygen uptake (VO2) increases in an exponential fashion in exercising muscles and stabilizes after 1-2 min eventually reaching a plateau or steady state where the energy demand is matched by the l vel of VO2. VO2 kinetics describes the distinct...... phases of the VO2 response at the onset of exercise. Fast VO2 kinetics are considered to be beneficial in intense endurance sports with competitions lasting ~2-8 min, whereas low VO2 at steady state (high efficiency) is considered beneficial especially in events of longer duration. To improve...

  17. X-ray diagnostic installation with an image intensifier TV chain and a dose rate control device

    Energy Technology Data Exchange (ETDEWEB)

    Duemmling, K; Schott, O

    1977-04-28

    The person performing the examination can key up the dose rate briefly via the X-ray tube current, e.g., if the movement of a contrast medium is to be observed on the video screen and only certain phases in this movement, which are of diagnostic significance, are to be viewed more closely. The upward change necessary to reduce quantum noise by a certain factor is made by means of a switch. This at the same time results in a reduction of brightness (over-exposure) of the X-ray image on the video screen by actuating an aperture system between the image intensifier, and the TV camera. To prevent the X-ray tube from being overloaded during key-up of the dose rate, a time limit switch is installed in the control system.

  18. A prototype detector using the neutron image intensifier and multi-anode type photomultiplier tube for pulsed neutron imaging

    International Nuclear Information System (INIS)

    Ishikawa, Hirotaku; Sato, Hirotaka; Hara, Kaoru Y.; Kamiyama, Takashi

    2016-01-01

    We developed a neutron two-dimensional (2-D) detector for pulsed neutron imaging as a prototype detector, which was composed of a neutron image intensifier and a multi-anode type photomultiplier tube. A neutron transmission spectrum of α-Fe plate was measured by the prototype detector, and compared with the one measured by a typical neutron 2-D detector. The spectrum was in reasonable agreement with the one measured by the typical detector in the neutron wavelength region above 0.15 nm. In addition, a neutron transmission image of a cadmium indicator was obtained by the prototype detector. The usefulness of the prototype detector for pulsed neutron imaging was demonstrated. (author)

  19. Importance of soil nitrogen and select intensifying measures in the soil-plant-fertilizer system demonstrated in sugar beets

    International Nuclear Information System (INIS)

    Rauhe, K.; Sielaff, B.; Barth, F.J.

    1981-01-01

    Sugar beets were gradually fertilized with 15 N-labelled nitrogen fertilizer without or in combination with irrigation. To gain optimum crop yields 180 - 200 kg/ha fertilizer nitrogen were required. Within the range of maximum yield the total nitrogen uptake amounted to 300 - 360 kg/ha under conditions of irrigation. Nitrogen was taken up from the fertilizer by 40% and from the soil by 60%. The immobilization rate of fertilizer nitrogen was near 30% after 2 years of vegetation. Only 33% and 25%, resp., of soil nitrogen could be replaced by fertilizing without and combined with irrigation, resp. It was shown that despite of increased application of the main intensifying factors, nitrogen and water, the soil nitrogen was mineralized intensively

  20. Uses of microchannel plate intensified detectors for imaging applications in the X-ray, EUV and visible wavelength regions

    International Nuclear Information System (INIS)

    Read, P.D.; Carter, M.K.; Pike, C.D.; Harrison, R.A.; Kent, B.J.; Swinyard, B.M.; Patchett, B.E.; Redfern, R.M.; Shearer, A.; Colhoun, M.

    1997-01-01

    The Rutherford Appleton laboratory photon counting detector (RALPCD) has been refined to meet project requirements for a flexible imaging arrangement with applications at X-ray, EUV and visible wavelengths. The basic detector design comprises commercially available high gain microchannel plate intensifiers fibre optically coupled to CID or CCD cameras, to form a modular detector arrangement with the appropriate RAL detection and centroiding software. Frames of data from the cameras are detected and centroided in a transputer or C40 parallel processor array where correction algorithms use look up tables to produce pattern free images at high resolution. Data from completed applications are used to illustrate the performance and future advances are discussed. (orig.)

  1. Effect of process intensifying parameters on the hydrodynamic cavitation based degradation of commercial pesticide (methomyl) in the aqueous solution.

    Science.gov (United States)

    Raut-Jadhav, Sunita; Saini, Daulat; Sonawane, Shirish; Pandit, Aniruddha

    2016-01-01

    Methomyl, a carbamate pesticide, is classified as a pesticide of category-1 toxicity and hence shows harmful effects on both human and aquatic life. In the present work, the degradation of methomyl has been studied by using hydrodynamic cavitation reactor (HC) and its combination with intensifying agents such as H2O2, fenton reagent and ozone (hybrid processes). Initially, the optimization of operating parameters such pH and inlet pressure to the cavitating device (circular venturi) has been carried out for maximizing the efficacy of hydrodynamic cavitation. Further degradation study of methomyl by the application of hybrid processes was carried out at an optimal pH of 2.5 and the optimal inlet pressure of 5 bar. Significant synergetic effect has been observed in case of all the hybrid processes studied. Synergetic coefficient of 5.8, 13.41 and 47.6 has been obtained by combining hydrodynamic cavitation with H2O2, fenton process and ozone respectively. Efficacy of individual and hybrid processes has also been obtained in terms of energy efficiency and extent of mineralization. HC+Ozone process has proved to be the most effective process having highest synergetic coefficient, energy efficiency and the extent of mineralization. The study has also encompassed the identification of intermediate by-products generated during the degradation and has proposed the probable degradation pathway. It has been conclusively established that hydrodynamic cavitation in the presence of intensifying agents can effectively be used for complete degradation of methomyl. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Low carbohydrate, high fat diet impairs exercise economy and negates the performance benefit from intensified training in elite race walkers

    Science.gov (United States)

    Ross, Megan L.; Garvican‐Lewis, Laura A.; Welvaert, Marijke; Heikura, Ida A.; Forbes, Sara G.; Mirtschin, Joanne G.; Cato, Louise E.; Strobel, Nicki; Sharma, Avish P.; Hawley, John A.

    2017-01-01

    Key points Three weeks of intensified training and mild energy deficit in elite race walkers increases peak aerobic capacity independent of dietary support.Adaptation to a ketogenic low carbohydrate, high fat (LCHF) diet markedly increases rates of whole‐body fat oxidation during exercise in race walkers over a range of exercise intensities.The increased rates of fat oxidation result in reduced economy (increased oxygen demand for a given speed) at velocities that translate to real‐life race performance in elite race walkers.In contrast to training with diets providing chronic or periodised high carbohydrate availability, adaptation to an LCHF diet impairs performance in elite endurance athletes despite a significant improvement in peak aerobic capacity. Abstract We investigated the effects of adaptation to a ketogenic low carbohydrate (CHO), high fat diet (LCHF) during 3 weeks of intensified training on metabolism and performance of world‐class endurance athletes. We controlled three isoenergetic diets in elite race walkers: high CHO availability (g kg−1 day−1: 8.6 CHO, 2.1 protein, 1.2 fat) consumed before, during and after training (HCHO, n = 9); identical macronutrient intake, periodised within or between days to alternate between low and high CHO availability (PCHO, n = 10); LCHF (diets providing chronic or periodised high‐CHO availability, and despite a significant improvement in V˙O2 peak , adaptation to the topical LCHF diet negated performance benefits in elite endurance athletes, in part due to reduced exercise economy. PMID:28012184

  3. Rationale and design of the GUIDE-IT study: Guiding Evidence Based Therapy Using Biomarker Intensified Treatment in Heart Failure.

    Science.gov (United States)

    Felker, G Michael; Ahmad, Tariq; Anstrom, Kevin J; Adams, Kirkwood F; Cooper, Lawton S; Ezekowitz, Justin A; Fiuzat, Mona; Houston-Miller, Nancy; Januzzi, James L; Leifer, Eric S; Mark, Daniel B; Desvigne-Nickens, Patrice; Paynter, Gayle; Piña, Ileana L; Whellan, David J; O'Connor, Christopher M

    2014-10-01

    The GUIDE-IT (Guiding Evidence Based Therapy Using Biomarker Intensified Treatment in Heart Failure) study is designed to determine the safety, efficacy, and cost-effectiveness of a strategy of adjusting therapy with the goal of achieving and maintaining a target N-terminal pro-B-type natriuretic peptide (NT-proBNP) level of levels provide key prognostic information in patients with HF. Therapies proven to improve outcomes in patients with HF are generally associated with decreasing levels of NPs, and observational data show that decreases in NP levels over time are associated with favorable outcomes. Results from smaller prospective, randomized studies of this strategy thus far have been mixed, and current guidelines do not recommend serial measurement of NP levels to guide therapy in patients with HF. GUIDE-IT is a prospective, randomized, controlled, unblinded, multicenter clinical trial designed to randomize approximately 1,100 high-risk subjects with systolic HF (left ventricular ejection fraction ≤40%) to either usual care (optimized guideline-recommended therapy) or a strategy of adjusting therapy with the goal of achieving and maintaining a target NT-proBNP level of study are followed up at regular intervals and after treatment adjustments for a minimum of 12 months. The primary endpoint of the study is time to cardiovascular death or first hospitalization for HF. Secondary endpoints include time to cardiovascular death and all-cause mortality, cumulative mortality, health-related quality of life, resource use, cost-effectiveness, and safety. The GUIDE-IT study is designed to definitively assess the effects of an NP-guided strategy in high-risk patients with systolic HF on clinically relevant endpoints of mortality, hospitalization, quality of life, and medical resource use. (Guiding Evidence Based Therapy Using Biomarker Intensified Treatment in Heart Failure [GUIDE-IT]; NCT01685840). Copyright © 2014 American College of Cardiology Foundation

  4. Development and evaluation of a novel low power, high frequency piezoelectric-based ultrasonic reactor for intensifying the transesterification reaction

    Directory of Open Access Journals (Sweden)

    Mortaza Aghbashlo

    2016-12-01

    Full Text Available In this study, a novel low power, high frequency piezoelectric-based ultrasonic reactor was developed and evaluated for intensifying the transesterification process. The reactor was equipped with an automatic temperature control system, a heating element, a precise temperature sensor, and a piezoelectric-based ultrasonic module. The conversion efficiency and specific energy consumption of the reactor were examined under different operational conditions, i.e., reactor temperature (40‒60 °C, ultrasonication time (6‒10 min, and alcohol/oil molar ratio (4:1‒8:1. Transesterification of waste cooking oil (WCO was performed in the presence of a base-catalyst (potassium hydroxide using methanol. According to the obtained results, alcohol/oil molar ratio of 6:1, ultrasonication time of 10 min, and reactor temperature of 60 °C were found as the best operational conditions. Under these conditions, the reactor converted WCO to biodiesel with a conversion efficiency of 97.12%, meeting the ASTM standard satisfactorily, while the lowest specific energy consumption of 378 kJ/kg was also recorded. It should be noted that the highest conversion efficiency of 99.3 %, achieved at reactor temperature of 60 °C, ultrasonication time of 10 min, and alcohol/oil molar ratio of 8:1, was not favorable as the associated specific energy consumption was higher at 395 kJ/kg. Overall, the low power, high frequency piezoelectric-based ultrasonic module could be regarded as an efficient and reliable technology for intensifying the transesterification process in terms of energy consumption, conversion efficiency, and processing time, in comparison with high power, low frequency ultrasonic system reported previously. Finally, this technology could also be considered for designing, developing, and retrofitting chemical reactors being employed for non-biofuel applications as well.

  5. Acceleration of peat drying by intensifying the heat and mass transfer; Turpeen kuivumisen nopeuttaminen laemmoen- ja aineensiirtoa tehostamalla

    Energy Technology Data Exchange (ETDEWEB)

    Hillebrand, K.

    1996-12-31

    The efficiency of peat production can be increased by intensifying peat drying. To intensify drying one has to know the effects of the different factors affecting the heat and mass transfer in the drying layer and in the soil. The objective of the study is to increase the degree of utilization of solar energy in drying of peat from the present level of 30% to 40% of the total incoming solar energy. In this way it is possible to reduce the peat production costs about 10%. A numerical drying model has been developed which describes the transfer of liquid water, water vapor and heat in the drying layer and in the soil. In addition, the interaction between the atmosphere and the drying layer, as well as the rainfall interception by the layer, infiltration, evaporation, and drainage have been taking into account. Daily input requirements include global solar radiation, air temperature and relative humidity, wind speed and precipitation. In addition to the weather data one has to know the characteristics of the drying layer and the soil. The numerical drying model was also used to study the effect of soil frost on peat drying and the possibilities to hinder the frost formation. Producing peat on the field which is still partly frozen, the drying of peat takes 10 - 25% longer time than under normal conditions, which means 5 - 25 hours longer drying period. By forming a porous, insulating layer on the top of the soil surface, one can hinder the frost formation significantly. Raising the groundwater level prevents, however, only a little the frost formation in peat soil

  6. Intensified Sampling in Response to a Salmonella Heidelberg Outbreak Associated with Multiple Establishments Within a Single Poultry Corporation.

    Science.gov (United States)

    Green, Alice; Defibaugh-Chavez, Stephanie; Douris, Aphrodite; Vetter, Danah; Atkinson, Richard; Kissler, Bonnie; Khroustalev, Allison; Robertson, Kis; Sharma, Yudhbir; Becker, Karen; Dessai, Uday; Antoine, Nisha; Allen, Latasha; Holt, Kristin; Gieraltowski, Laura; Wise, Matthew; Schwensohn, Colin

    2018-03-01

    On June 28, 2013, the Food Safety and Inspection Service (FSIS) was notified by the Centers for Disease Control and Prevention (CDC) of an investigation of a multistate cluster of illnesses of Salmonella enterica serovar Heidelberg. Since case-patients in the cluster reported consumption of a variety of chicken products, FSIS used a simple likelihood-based approach using traceback information to focus on intensified sampling efforts. This article describes the multiphased product sampling approach taken by FSIS when epidemiologic evidence implicated chicken products from multiple establishments operating under one corporation. The objectives of sampling were to (1) assess process control of chicken slaughter and further processing and (2) determine whether outbreak strains were present in products from these implicated establishments. As part of the sample collection process, data collected by FSIS personnel to characterize product included category (whole chicken and type of chicken parts), brand, organic or conventional product, injection with salt solutions or flavorings, and whether product was skinless or skin-on. From the period September 9, 2013, through October 31, 2014, 3164 samples were taken as part of this effort. Salmonella percent positive declined from 19.7% to 5.3% during this timeframe as a result of regulatory and company efforts. The results of intensified sampling for this outbreak investigation informed an FSIS regulatory response and corrective actions taken by the implicated establishments. The company noted that a multihurdle approach to reduce Salmonella in products was taken, including on-farm efforts such as environmental testing, depopulation of affected flocks, disinfection of affected houses, vaccination, and use of various interventions within the establishments over the course of several months.

  7. Digital subtraction angiography of lower limb arteries using and automatic table translation. Feasibility. Preliminary results

    International Nuclear Information System (INIS)

    Seka, R.; Amiel, M.; Boller, A.; Chapelon, C.; Clermont, A.; Revel, D.; Pinet, F.

    1988-01-01

    Digital subtraction angiography (DSA) as a method of evaluating lower limb arteries required examination of one limb at a time up to now. Moreover repeated injections of contrast material were necessary. This problem was mainly due to the relative small image intensifier field available and to the difficulty of repositionning the patient between mask and image acquisition. The preliminary results obtained with 24 patients studied on angiographic unit equipped with: a DSA system (DG 300-CGR) using 512x512 matrix size, an angiographic table (Angix M 200) allowing an automatic sequantial translation, a removable image intensifier using a 16 inch field below the table, are reported. Thus, all those characteristics allow DSA of lower limb arteries. Only one injection of contrast material (Ioxaglate: 80 ml at 8-10 ml/second) was used per procedure. This, usually, allows good quality examination of lower limb arteries [fr

  8. Work and Consumption in Digital Capitalism: From Commodity Abstraction to 'Eidetisation'

    Directory of Open Access Journals (Sweden)

    Xavi Cava

    2018-05-01

    Full Text Available The digital sphere can be studied as one of the most mature materialisations of the process of abstraction that accompanies capitalism. It is also a framework where subjectivity internalises the abstract form of commodities even further. In this sense, the Internet is the home of an abstract nature that is linked to a particular reification process that characterises post-Fordist production and consumption. This process can be named “eidetisation”. My basic assumption is that the process of reification is being intensified with the digitalisation of the capitalist system. I will begin discussing the concept of reification as a specific form of alienation, stressing that the reification of society changes and intensifies in as much as capitalist production and consumption evolve. Then I will consider the process of abstraction as one of the main elements of reification. Finally, I will try to identify some distinctive traits within the process of “eidetisation”.

  9. 用新型活化剂强化原油蒸馏过程的研究%INTENSIFYING DISTILLATION OF CRUDE OIL BY USING NEW ACTIVATOR

    Institute of Scientific and Technical Information of China (English)

    刘红研; 沙峰; 詹亚力; 朱建华

    2001-01-01

    By using activator to change the state of crude oil and to diminish the size of dispersed phase,mass transfer in distillation process is intensified and distillate yield is increased.In this work,the new activators R1 and R2 were used as the additives respectively,and the intensifying effects to Daqing crude oil were examined at different concentrations and liquid phase temperatures by means of simple distillation and TBP distillation.The interaction mechanisms between the new activators and the crude oil or residues were analyzed,the intensifying effects by the new activators were also studied.Finally,the conceptual technique of "chemical intensification distillation”was put forward.

  10. Digital Simulation in the Geosciences

    Directory of Open Access Journals (Sweden)

    Alexandr A. Lobanov

    2014-09-01

    Full Text Available This article provides an analysis of methods for digital modeling in the area of Earth Sciences. The author illustrates the difference between digital modeling in radio communication and that in the area of Earth Sciences. The article examines the integration aspect of digital models, demonstrates the advantages of digital over analog models, and illustrates that digital models are discrete. The author outlines the characteristics of digital modeling and illustrates the logical structure of digital models.

  11. Digital radiology and ultrasound

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.

    1991-01-01

    With the access to digital methods for handling and processing images in general, many medical imaging methods are becoming more effectively handled digitally. This applies in particular to basically digital techniques such as CT and MR but also now includes Nuclear Medicine (NM), Ultrasound (US) and a variety of radiological procedures such as Digital Subtraction Angiography (DSA) and Fluoroscopy (DF). The access to conventional projection images by stimulatable plates (CR) or by digitization of film makes all of radiology potentially accessible, and the management of such images by a network is the basic aim of Picture Archiving and Communication Systems (PACS). However, it is suggested that in order for such systems to be of greater value, that way in which such images are treated needs to change, that is, digital images can be used to derive additional clinical value by appropriate processing

  12. Digital cine-imaging

    International Nuclear Information System (INIS)

    Masuda, Kazuhiro

    1992-01-01

    Digitization of fluoroscopic images has been developed for the digital cine imaging system as a result of the computer technology, television technology, and popularization of interventional radiology. Present digital cine imaging system is able to offer images similar to cine film because of the higher operatability and better image quality with the development of interventional radiology. As a result, its higher usefulness for catheter diagnosis examination except for interventional radiology was reported, and the possibility of having filmless cine is close to becoming a reality. However several problems have been pointed out, such as spatial resolution, time resolution, storage and exchangeability of data, disconsolidated viewing functions, etc. Anyhow, digital cine imaging system has some unresolved points and lots the needs to be discussed. The tendency of digitization is the passage of the time and we have to promote a study for more useful digital cine imaging system in team medical treatment which centers on the patients. (author)

  13. Theory of Digital Automata

    CERN Document Server

    Borowik, Bohdan; Lahno, Valery; Petrov, Oleksandr

    2013-01-01

    This book serves a dual purpose: firstly to combine the treatment of circuits and digital electronics, and secondly, to establish a strong connection with the contemporary world of digital systems. The need for this approach arises from the observation that introducing digital electronics through a course in traditional circuit analysis is fast becoming obsolete. Our world has gone digital. Automata theory helps with the design of digital circuits such as parts of computers, telephone systems and control systems. A complete perspective is emphasized, because even the most elegant computer architecture will not function without adequate supporting circuits. The focus is on explaining the real-world implementation of complete digital systems. In doing so, the reader is prepared to immediately begin design and implementation work. This work serves as a bridge to take readers from the theoretical world to the everyday design world where solutions must be complete to be successful.

  14. Digital collections and exhibits

    CERN Document Server

    Denzer, Juan

    2015-01-01

    Today's libraries are taking advantage of cutting-edge technologies such as flat panel displays using touch, sound, and hands-free motions to design amazing exhibits using everything from simple computer hardware to advanced technologies such as the Microsoft Kinect. Libraries of all types are striving to add new interactive experiences for their patrons through exciting digital exhibits, both online and off. Digital Collections and Exhibits takes away the mystery of designing stunning digital exhibits to spotlight library trea

  15. The digital computer

    CERN Document Server

    Parton, K C

    2014-01-01

    The Digital Computer focuses on the principles, methodologies, and applications of the digital computer. The publication takes a look at the basic concepts involved in using a digital computer, simple autocode examples, and examples of working advanced design programs. Discussions focus on transformer design synthesis program, machine design analysis program, solution of standard quadratic equations, harmonic analysis, elementary wage calculation, and scientific calculations. The manuscript then examines commercial and automatic programming, how computers work, and the components of a computer

  16. Digital Textile Printing

    OpenAIRE

    Moltchanova, Julia

    2011-01-01

    Rapidly evolving technology of digital printing opens new opportunities on many markets. One of them is the printed fabric market where printing companies as well as clients benefit from new printing methods. This thesis focuses on the digital textile printing technology and its implementation for fabric-on-demand printing service in Finland. The purpose of this project was to study the technology behind digital textile printing, areas of application of this technology, the requirements ...

  17. Digital Sensor Technology

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Ken D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Quinn, Edward L. [Technology Resources, Dana Point, CA (United States); Mauck, Jerry L. [Technology Resources, Dana Point, CA (United States); Bockhorst, Richard M. [Technology Resources, Dana Point, CA (United States)

    2015-02-01

    The nuclear industry has been slow to incorporate digital sensor technology into nuclear plant designs due to concerns with digital qualification issues. However, the benefits of digital sensor technology for nuclear plant instrumentation are substantial in terms of accuracy and reliability. This paper, which refers to a final report issued in 2013, demonstrates these benefits in direct comparisons of digital and analog sensor applications. Improved accuracy results from the superior operating characteristics of digital sensors. These include improvements in sensor accuracy and drift and other related parameters which reduce total loop uncertainty and thereby increase safety and operating margins. An example instrument loop uncertainty calculation for a pressure sensor application is presented to illustrate these improvements. This is a side-by-side comparison of the instrument loop uncertainty for both an analog and a digital sensor in the same pressure measurement application. Similarly, improved sensor reliability is illustrated with a sample calculation for determining the probability of failure on demand, an industry standard reliability measure. This looks at equivalent analog and digital temperature sensors to draw the comparison. The results confirm substantial reliability improvement with the digital sensor, due in large part to ability to continuously monitor the health of a digital sensor such that problems can be immediately identified and corrected. This greatly reduces the likelihood of a latent failure condition of the sensor at the time of a design basis event. Notwithstanding the benefits of digital sensors, there are certain qualification issues that are inherent with digital technology and these are described in the report. One major qualification impediment for digital sensor implementation is software common cause failure (SCCF).

  18. Preserving Digital Materials

    CERN Document Server

    Harvey, Ross

    2011-01-01

    This book provides a single-volume introduction to the principles, strategies and practices currently applied by librarians and recordkeeping professionals to the critical issue of preservation of digital information. It incorporates practice from both the recordkeeping and the library communities, taking stock of current knowledge about digital preservation and describing recent and current research, to provide a framework for reflecting on the issues that digital preservation raises in professional practice.

  19. Dakwah di Era Digital

    OpenAIRE

    Budiantoro, Wahyu

    2018-01-01

    These days dakwah is not only interpreted as transformation of a pure religious value, but also transformation of a more relevant value including many aspects in digital era. Digital era is when society succumbed into the flow of information causing cultural shock and difficulties on synthesizing meaning from those scattered information. Dakwah on Digital age must accommodate societal needs which tend to move into a mass society. It results in strategy and more humane and innovative dakwah me...

  20. The Digital Imperative

    OpenAIRE

    Veling, Louise; Murnane, Sinéad; Carcary, Marian; Zlydareva, Olga

    2014-01-01

    The pervasiveness of digital technologies and their potential for reshaping the industry landscape dictates that organizations operating today have little choice but to incorporate digital technologies into their business strategies. Failure to do so will impede the business’s viability, and may ultimately lead to business failure. However, for those organizations that successfully transition to digital business, unprecedented business opportunities exist for value creation and reali...

  1. Digital piracy : theory

    OpenAIRE

    BELLEFLAMME, Paul; PEITZ, Martin

    2010-01-01

    This article reviews recent theoretical contributions on digital piracy. It starts by elaborating on the reasons for intellectual property protection, by reporting a few facts about copyright protection, and by examining reasons to become a digital pirate. Next, it provides an exploration of the consequences of digital piracy, using a base model and several extensions (with consumer sampling, network effects, and indirect appropriation). A closer look at market-structure implications of end-u...

  2. La radio digital

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Cortés S.

    2015-01-01

    Full Text Available La radio digital es un producto de la llamada convergencia digital. Las nuevas tecnologías interconectadas permiten la aparición de nuevos modos de audiencia y la implementación de herramientas versátiles. Habla del problema de los estándares, de la radio satelital, la radio digital terrestre, las radios internacionales, la interactividad.

  3. Easy digital engineering

    International Nuclear Information System (INIS)

    Jin, Dal Bok

    2002-02-01

    This book lists basic of digital engineering, number system and digital code, Boolean algebra and basic logic circuit, simplify of logical expression, combinational circuit, arithmetic circuit, multivibrator circuit, sequential circuit, memory unit of semiconductor and logical element for program, D/A converter and A/D converter, logic element and integrated circuit and logic circuit and micro controller. It has exercises and answers about digital engineering and summary in the end of each chapter.

  4. X-ray image intensifier for cardiovascular diagnosis. Development of RTP 9203 B-P4 and evaluation of image quality

    Energy Technology Data Exchange (ETDEWEB)

    Obata, Y; Suzuki, A; Noji, T; Harao, N [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    1979-07-01

    The high utility of 35-mm cine fluorography with high-quality X-ray image intensifier has recently been acknowledged in the field of cardiovascular diagnosis. The newly developed 9-inch dual-field X-ray image intensifier is particularly suitable for 35-mm cinefluorography. The main characteristics of this tube are the increased contrast, brightness and resolution of images and the reduced quantum noise. These characteristics are caused by the CsI input phosphor screen which has a ''light-guide effect'', a high-sensitivity photocathode and a dark output screen. The tube is equipped with a high-voltage power supply with high reliability.

  5. Effect of 2-wk intensified training and inactivity on muscle Na+/K+ pump expression, phospholemman (FXYD1) phosphorylation and performance in soccer players

    DEFF Research Database (Denmark)

    Thomassen, Martin; Christensen, Peter Møller; Gunnarsson, Thomas Gunnar Petursson

    2010-01-01

    The present study examined muscle adaptations and alterations in performance of highly trained soccer players with intensified training or training cessation. Eighteen elite soccer players were for a 2-wk period assigned to either a group which performed high intensity training with a reduction....... The present data suggest that short-term intensified training even for trained soccer players can increase muscle Na(+)/K(+) pump alpha2 isoform expression and that cessation of training for two weeks does not affect the expression of Na(+)/K(+) pump isoforms. Resting phosphorylation status of the Na...

  6. Debunking the "Digital Native": Beyond Digital Apartheid, towards Digital Democracy

    Science.gov (United States)

    Brown, C.; Czerniewicz, L.

    2010-01-01

    This paper interrogates the currently pervasive discourse of the "net generation" finding the concept of the "digital native" especially problematic, both empirically and conceptually. We draw on a research project of South African higher education students' access to and use of Information and Communication Technologies (ICTs)…

  7. Digital Natives and Digital Divide: Analysing Perspective for Emerging Pedagogy

    Science.gov (United States)

    Onye, Uriel U.; Du, Yunfei

    2016-01-01

    This paper addresses the concepts of digital natives and digital divide from the perspective of the digital outsiders (part of digital natives). It takes a critical look at the implications of available ICT in both developed and underdeveloped countries in the fight against digital divide. The major contribution to literature is by drawing…

  8. The digital media handbook

    CERN Document Server

    Dewdney, Andrew

    2013-01-01

    The new edition of The Digital Media Handbook presents an essential guide to the historical and theoretical development of digital media, emphasising cultural continuity alongside technological change, and highlighting the emergence of new forms of communication in contemporary networked culture.Andrew Dewdney and Peter Ride present detailed critical commentary and descriptive historical accounts, as well as a series of interviews from a range of digital media practitioners, including producers, developers, curators and artists.The Digital Media Handbook highlights key concerns of today's prac

  9. Digitization of conventional radiographs

    International Nuclear Information System (INIS)

    Wenz, W.; Buitrago-Tellez, C.; Blum, U.; Hauenstein, K.H.; Gufler, H.; Meyer, E.; Ruediger, K.

    1992-01-01

    The diagnostic value of a digitization system for analogue films based on a charge-coupled-device (CCD) scanner with adjustable resolution of 2.5 or 5 lp/mm was assessed. Some 110 skeletal radiographs, 50 contrast studies, including 25 of patients with Crohn's disease, and 70 abdominal plain films before and after successful lithotripsy for renal stones were digitized. Receiver operating characteristic (ROC) studies showed improved detection of cortical and trabecular defects with contrast-optimized digitized films. Edge enhancement algorithms yielded no additional information. Inflammatory lesions of Crohn's disease were detected equally well by conventional films and digitized images. A statistically significant improvement (p [de

  10. Digital security technology simplified.

    Science.gov (United States)

    Scaglione, Bernard J

    2007-01-01

    Digital security technology is making great strides in replacing analog and other traditional security systems including CCTV card access, personal identification and alarm monitoring applications. Like any new technology, the author says, it is important to understand its benefits and limitations before purchasing and installing, to ensure its proper operation and effectiveness. This article is a primer for security directors on how digital technology works. It provides an understanding of the key components which make up the foundation for digital security systems, focusing on three key aspects of the digital security world: the security network, IP cameras and IP recorders.

  11. Digitally-Driven Architecture

    Directory of Open Access Journals (Sweden)

    Henriette Bier

    2014-07-01

    Full Text Available The shift from mechanical to digital forces architects to reposition themselves: Architects generate digital information, which can be used not only in designing and fabricating building components but also in embedding behaviours into buildings. This implies that, similar to the way that industrial design and fabrication with its concepts of standardisation and serial production influenced modernist architecture, digital design and fabrication influences contemporary architecture. While standardisation focused on processes of rationalisation of form, mass-customisation as a new paradigm that replaces mass-production, addresses non-standard, complex, and flexible designs. Furthermore, knowledge about the designed object can be encoded in digital data pertaining not just to the geometry of a design but also to its physical or other behaviours within an environment. Digitally-driven architecture implies, therefore, not only digitally-designed and fabricated architecture, it also implies architecture – built form – that can be controlled, actuated, and animated by digital means.In this context, this sixth Footprint issue examines the influence of digital means as pragmatic and conceptual instruments for actuating architecture. The focus is not so much on computer-based systems for the development of architectural designs, but on architecture incorporating digital control, sens­ing, actuating, or other mechanisms that enable buildings to inter­act with their users and surroundings in real time in the real world through physical or sensory change and variation.

  12. Digitally-Driven Architecture

    Directory of Open Access Journals (Sweden)

    Henriette Bier

    2010-06-01

    Full Text Available The shift from mechanical to digital forces architects to reposition themselves: Architects generate digital information, which can be used not only in designing and fabricating building components but also in embedding behaviours into buildings. This implies that, similar to the way that industrial design and fabrication with its concepts of standardisation and serial production influenced modernist architecture, digital design and fabrication influences contemporary architecture. While standardisa­tion focused on processes of rationalisation of form, mass-customisation as a new paradigm that replaces mass-production, addresses non-standard, complex, and flexible designs. Furthermore, knowledge about the designed object can be encoded in digital data pertaining not just to the geometry of a design but also to its physical or other behaviours within an environment. Digitally-driven architecture implies, therefore, not only digitally-designed and fabricated architecture, it also implies architecture – built form – that can be controlled, actuated, and animated by digital means. In this context, this sixth Footprint issue examines the influence of digital means as prag­matic and conceptual instruments for actuating architecture. The focus is not so much on computer-based systems for the development of architectural designs, but on architecture incorporating digital control, sens­ing, actuating, or other mechanisms that enable buildings to inter­act with their users and surroundings in real time in the real world through physical or sensory change and variation.

  13. Exploring digital professionalism.

    Science.gov (United States)

    Ellaway, Rachel H; Coral, Janet; Topps, David; Topps, Maureen

    2015-01-01

    The widespread use of digital media (both computing devices and the services they access) has blurred the boundaries between our personal and professional lives. Contemporary students are the last to remember a time before the widespread use of the Internet and they will be the first to practice in a largely e-health environment. This article explores concepts of digital professionalism and their place in contemporary medical education, and proposes a series of principles of digital professionalism to guide teaching, learning and practice in the healthcare professions. Despite the many risks and fears surrounding their use, digital media are not an intrinsic threat to medical professionalism. Professionals should maintain the capacity for deliberate, ethical, and accountable practice when using digital media. The authors describe a digital professionalism framework structured around concepts of proficiency, reputation, and responsibility. Digital professionalism can be integrated into medical education using strategies based on awareness, alignment, assessment, and accountability. These principles of digital professionalism provide a way for medical students and medical practitioners to embrace the positive aspects of digital media use while being mindful and deliberate in its use to avoid or minimize any negative consequences.

  14. Radiographic film digitizing devices

    International Nuclear Information System (INIS)

    McFee, W.H.

    1988-01-01

    Until recently, all film digitizing devices for use with teleradiology or picture archiving and communication systems used a video camera to capture an image of the radiograph for subsequent digitization. The development of film digitizers that use a laser beam to scan the film represents a significant advancement in digital technology, resulting in improved image quality compared with video scanners. This paper discusses differences in resolution, efficiency, reliability, and the cost between these two types of devices. The results of a modified receiver operating characteristic comparison study of a video scanner and a laser scanner manufactured by the same company are also discussed

  15. Cognitive Hacking and Digital Government: Digital Identity

    Directory of Open Access Journals (Sweden)

    Paul Thompson

    2004-04-01

    Full Text Available Recently the National Center for Digital Government held a workshop on "The Virtual Citizen: Identity, Autonomy, and Accountability: A Civic Scenario Exploration of the Role of Identity in On-Line. Discussions at the workshop focused on five scenarios for future authentication policies with respect to digital identity. The underlying technologies considered for authentication were: biometrics: cryptography, with a focus on digital signatures; secure processing/computation; and reputation systems. Most discussion at the workshop focused on issues related to authentication of users of digital government, but, as implied by the inclusion of a scenario related to ubiquitous identity theft, there was also discussion of problems related to misinformation, including cognitive hacking. Cognitive hacking refers to a computer or information system attack that relies on changing human users' perceptions and corresponding behaviors in order to succeed. This paper describes cognitive hacking, suggests countermeasures, and discusses the implications of cognitive hacking for identity in digital government. In particular, spoofing of government websites and insider misuse are considered.

  16. Automatic analysis of quality of images from X-ray digital flat detectors

    International Nuclear Information System (INIS)

    Le Meur, Y.

    2009-04-01

    Since last decade, medical imaging has grown up with the development of new digital imaging techniques. In the field of X-ray radiography, new detectors replace progressively older techniques, based on film or x-ray intensifiers. These digital detectors offer a higher sensibility and reduced overall dimensions. This work has been prepared with Trixell, the world leading company in flat detectors for medical radiography. It deals with quality control on digital images stemming from these detectors. High quality standards of medical imaging impose a close analysis of the defects that can appear on the images. This work describes a complete process for quality analysis of such images. A particular focus is given on the detection task of the defects, thanks to methods well adapted to our context of spatially correlated defects in noise background. (author)

  17. Inspection reliability comparison of digital radiography, film radiography and radioscopy for inspection of Inconel welds

    International Nuclear Information System (INIS)

    Meade, W.; Kidwell, C.; Warren, G.

    2004-01-01

    Digital Radiography offers the promise of economic and environmental advantages over traditional film based inspection. Boeing Commercial Aircraft Group has an on-going effort to evaluate this emerging radiographic method for production of aerospace hardware. Included in this effort was a program to evaluate the potential for utilizing amorphous silicon based digital radiography for the inspection of inconel weldments in engine ducting. For this particular program, probability of detection (POD) studies were conducted to compare the reliability of digital radiography with the existing production processes that utilize film radiography and image-intensifier based radioscopy. Cycle time studies were also conducted to determine the potential economic benefit for switching to the new process. The methodology and findings of this comparison are presented. (author)

  18. Inspection reliability comparison of digital radiography, film radiography and radioscopy for inspection of Inconel welds

    Energy Technology Data Exchange (ETDEWEB)

    Meade, W.; Kidwell, C.; Warren, G. [Boeing Commercial Aircraft Group, Renton, Washington (United States)

    2004-07-01

    Digital Radiography offers the promise of economic and environmental advantages over traditional film based inspection. Boeing Commercial Aircraft Group has an on-going effort to evaluate this emerging radiographic method for production of aerospace hardware. Included in this effort was a program to evaluate the potential for utilizing amorphous silicon based digital radiography for the inspection of inconel weldments in engine ducting. For this particular program, probability of detection (POD) studies were conducted to compare the reliability of digital radiography with the existing production processes that utilize film radiography and image-intensifier based radioscopy. Cycle time studies were also conducted to determine the potential economic benefit for switching to the new process. The methodology and findings of this comparison are presented. (author)

  19. Possible radiation dose reduction by using digital X-ray equipment

    International Nuclear Information System (INIS)

    Horvathova, M.; Nikodemova, D.; Prikazska, M.

    2001-01-01

    The radiation load of population all over the world from medical examinations clearly demonstrates the importance of the introduction of the quality assurance and quality control programmes into the activities of radiology departments. The basic aim of quality assurance program is to ensure that the radiation dose is kept as low as reasonably practicable while still providing an adequate image quality. As many other fields, the rapid development of techniques brought change-over from the conventional analogue technique to the digital technique. In this process, the conventional X-ray film is being abandoned and images are being viewed on either laser film or monitor. The main advantages of using digital equipment lay in improved image quality and diagnostic accuracy through digital image processing, reduction in patients exposure, cost reduction by reduction of the film usage, more efficient storage and retrieval of radiographic images through picture archiving. Several studies that have been conducted for comparison of various diagnostic examinations show , that there is potential for dose saving in the digital image intensifier technique. The aim of this study was to compare measured values of dose-area product for colon investigations using different X-ray equipment types, two digital and two analogue. Our material consisted of 169 randomly selected patients, 115 of them were examined with digital equipment and 54 patients with the analogue equipment. The obtained results have confirmed the dose reduction and increase of diagnostic accuracy when using the digital equipment, with the added benefit of a good image quality. (authors)

  20. Need for New Optimisation Strategies in CR and Direct Digital Radiography

    International Nuclear Information System (INIS)

    Busch, H.P.

    2000-01-01

    Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, digital subtraction radiography and to fluoroscopy. Further work should lead to a definition of reference values for the dose and the image quality. This has to be done first for single exposures and fluoroscopic mode and secondly for diagnostic and interventional procedures. (author)

  1. New techniques in digital holography

    CERN Document Server

    Picart, Pascal

    2015-01-01

    A state of the art presentation of important advances in the field of digital holography, detailing advances related to fundamentals of digital holography, in-line holography applied to fluid mechanics, digital color holography, digital holographic microscopy, infrared holography, special techniques in full field vibrometry and inverse problems in digital holography

  2. Digital temperature meter

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S

    1982-01-01

    Digital temperature meter for precise temperature measurements is presented. Its parts such as thermostat, voltage-frequency converter and digital frequency meter are described. Its technical parameters such as temperature range 50degC-700degC, measurement precision 1degC, measurement error +-1degC are given. (A.S.).

  3. Changing State Digital Libraries

    Science.gov (United States)

    Pappas, Marjorie L.

    2006-01-01

    Research has shown that state virtual or digital libraries are evolving into websites that are loaded with free resources, subscription databases, and instructional tools. In this article, the author explores these evolving libraries based on the following questions: (1) How user-friendly are the state digital libraries?; (2) How do state digital…

  4. Digital signage sobre IP

    OpenAIRE

    Casademont Filella, Albert

    2012-01-01

    Projecte que versa sobre el disseny i la implementació d'un sistema de Digital Signage (Cartelleria Digital) sobre IP, creant un gestor que permeti controlar de forma remota tot un conjunt de petits dispositius connectats a pantalles que emeten continguts multimèdia com vídeos, imatges, feeds rss...

  5. Digital gaming expertise

    DEFF Research Database (Denmark)

    Toft-Nielsen, Claus

    In a digitally saturated environment digital media users of all kinds, engaged in different areas of activity, are increasingly categorized in terms of their ability to appropriate and use digital media – they are regarded as non-users, experts, natives, or literates for instance. Within communic......In a digitally saturated environment digital media users of all kinds, engaged in different areas of activity, are increasingly categorized in terms of their ability to appropriate and use digital media – they are regarded as non-users, experts, natives, or literates for instance. Within...... communication and game studies there are multiple understandings of how digital expertise is expressed and performed, and subsequently how these expressions and performances can be valued, understood and theorized within the research community. Among other things expertise with and within digital games has......-of-game (Schrøder, 2003) in a three-year-long study of men and women (couples and singles) playing the largest Massively Multiplayer Online Role-Playing Game to date, World of Warcraft. In focusing on how different aspects of gaming expertise are articulated, negotiated, and performed, I aim to illustrate how...

  6. The First Digit 1

    Indian Academy of Sciences (India)

    IAS Admin

    1075. RESONANCE | December 2013. GENERAL | ARTICLE. Table 2. The first digits distri- bution according to Benford's law. First Frequency. Digit. 1. 30.1 %. 2. 17.6 %. 3. 12.4 %. 4. 9.7 %. 5. 7.9 %. 6. 6.7 %. 7. 5.8 %. 8. 5.1 %. 9. 4.5 % ...

  7. Digital Cultural Heritage

    NARCIS (Netherlands)

    Navarrete, T.; Rizzo, I.; Mignosa, A.

    2013-01-01

    What is the impact of media technology on the supply and demand of heritage with what is usually described as digitization? This chapter presents the concept of digitization as concerning far more than just the introduction of computers, the development of databases and websites, and the conversion

  8. Digital formidling af kulturarv

    DEFF Research Database (Denmark)

    En af tidens store kulturelle dagsordner drejer sig om digital tilgængeliggørelse af kulturarv. Fortidens spor dukker op i nye former på nettet - næsten alle kulturinstitutioner arbejder med, og befolkningen har fået helt nye muligheder for at se med og deltage. Digital formidling af kulturarv...

  9. Digitizing migration heritage

    DEFF Research Database (Denmark)

    Marselis, Randi

    2011-01-01

    Museums are increasingly digitizing their collections and making them available to the public on-line. Creating such digital resources may become means for social inclusion. For museums that acknowledge migration history and cultures of ethnic minority groups as important subjects in multiethnic...

  10. Beyond Digital Citizenship

    Science.gov (United States)

    Mitchell, Lynn

    2016-01-01

    Conversations in middle school about digital citizenship tend to focus on the responsibilities of citizenship and the issues of surveillance, safety, cyberbullying, and internet etiquette. While these are important and essential conversations, digital citizenship education needs to consider youth political identity and democratic participation in…

  11. Navigate the Digital Rapids

    Science.gov (United States)

    Lindsay, Julie; Davis, Vicki

    2010-01-01

    How can teachers teach digital citizenship when the digital landscape is changing so rapidly? How can teachers teach proper online social interactions when the students are outside their classroom and thus outside their control? Will encouraging students to engage in global collaborative environments land teachers in hot water? These are the…

  12. Monetizing Digital Assets

    Directory of Open Access Journals (Sweden)

    Felician ALECU

    2013-04-01

    Full Text Available This article covers the options the digital content creators have to monetize their creations. The simplest solution seems to be the winning one, so by enabling the ads, the digital content may be quickly transformed into money with no cost.

  13. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...

  14. Recurrent infantile digital fibromatosis

    African Journals Online (AJOL)

    We present a case of an 8-year-old-boy with recurrent infantile digital fibromatosis (IDF) who presented with new ... Keywords: fibrous tumors, inclusion body fibromatosis, infantile digital fibromatosis, spindle cells, Reye tumor .... watch-and-wait strategy for patients with histologically confirmed IDF nodules that do not cause ...

  15. Practical digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Beverly E. [Washington Univ., Seattle, WA (United States)]|[Virginia Mason Medical Center, VA (United States)

    2008-07-01

    This book is meant for the radiologist who is facing the challenge of organizing a digital mammographic imaging center. This text is meant to be a practical book that provides information about digital mammographic physics and equipment which will allow one to intelligently compare technologies and systems. Some of the major challenges include: large expense; rapidly changing technology, and inconsistent connectivity; and finally, need for strong information technology support. The initial conversion cost to digital mammographic imaging is relatively expensive due to the cost of digital mammography hardware, software, and storage. Virtually all other imaging modalities are being converted to purely digital storage and transfer, and the digital trend in mammography is inevitable. Technical advantages of digital mammography are described. However, the improved flexibility in image display and transfer are some of its strongest features. In conclusion, although there are increasing imaging modalities that may be used to evaluate breast disease, mammography will continue to play a key role in detecting breast cancer. To be an effective imager, the radiologist should become familiar with digital mammography and understand its role within the increasing complex structure of breast imaging techniques.

  16. Practical digital mammography

    International Nuclear Information System (INIS)

    Hashimoto, Beverly E.

    2008-01-01

    This book is meant for the radiologist who is facing the challenge of organizing a digital mammographic imaging center. This text is meant to be a practical book that provides information about digital mammographic physics and equipment which will allow one to intelligently compare technologies and systems. Some of the major challenges include: large expense; rapidly changing technology, and inconsistent connectivity; and finally, need for strong information technology support. The initial conversion cost to digital mammographic imaging is relatively expensive due to the cost of digital mammography hardware, software, and storage. Virtually all other imaging modalities are being converted to purely digital storage and transfer, and the digital trend in mammography is inevitable. Technical advantages of digital mammography are described. However, the improved flexibility in image display and transfer are some of its strongest features. In conclusion, although there are increasing imaging modalities that may be used to evaluate breast disease, mammography will continue to play a key role in detecting breast cancer. To be an effective imager, the radiologist should become familiar with digital mammography and understand its role within the increasing complex structure of breast imaging techniques

  17. Educating Digital Citizens

    Science.gov (United States)

    Tan, Thomas

    2011-01-01

    Digital citizenship is how educators, citizens, and parents can teach where the lines of cyber safety and ethics are in the interconnected online world their students will inhabit. Aside from keeping technology users safe, digital citizenship also prepares students to survive and thrive in an environment embedded with information, communication,…

  18. Digital Rights Management

    NARCIS (Netherlands)

    Koster, P.; Jonker, Willem; Blanken, Henk; de Vries, A.P.; Blok, H.E.; Feng, L.

    2007-01-01

    Digital Rights Management, or DRM for short, is a much-discussed topic nowadays. The main reason for this is that DRM technology is often mentioned in the context of protection of digital audio and video content, for example to avoid large scale copying of CDs and DVDs via peer-to-peer networks in

  19. Digitalization of daycare institutions

    DEFF Research Database (Denmark)

    Chimirri, Niklas Alexander

    in the intergenerational interaction with as well as the intragenerational interaction among daycare children. To some extent, digital media usage, foremost of tablet computers, has seen a discursive and material normalization across a number Danish daycare institutions before at all clarifying how it could be rendered...... as on situated sociomaterial approaches to critical psychological practice research in order to inquire into possible specificities of digital media device usage: How is this usage similar to and different from interacting via other material-communicative devices in a pedagogical practice? How do digital media......The digitalization of Danish daycare institutions is not only affecting the ways staff is documenting and reporting on its pedagogical work. It also appears to be redefining what pedagogical work itself is about, given the drastic increase in deployment of digital (mobile) media devices...

  20. Creative Digital Media Practices

    DEFF Research Database (Denmark)

    Frølunde, Lisbeth

    , 2006, 2009), machinima (machine + cinema + anime, real-time animation captured in games etc.), and the digital storytelling movement. A dialogic perspective on the diversity of digital media practices opens up for understanding the complex evolution of language on socio-historical, cultural......The presentation reviews the interplay of dialogic (Bakhtin, 1981) and multimodal theories on media production practices, with attention to visual communication (Kress and van Leeuwen, 2001, 2006). This theoretical approach aids in reflecting on digital media practices as novel (new) sign systems...... develop a collaborative digital storytelling showcase for their own digital stories about Roskilde University. This course is intended to bring up reflections on the wider phenomenon of contemporary media practices, such as: YouTube, DIY (do-it-yourself) filmmaking or homemade, garage cinema (Jenkins...

  1. Digital Technology Entrepreneurship

    DEFF Research Database (Denmark)

    Giones, Ferran; Brem, Alexander

    2017-01-01

    Technology entrepreneurship is an established concept in academia. However, recent developments in the context of digital entrepreneurship call for revision and advance- ment. The multiple possible combinations of technology and entrepreneurship have res- ulted in a diversity of phenomena...... with significantly different characteristics and socio-economic impact. This article is focused on the identification and description of technology entrepreneurship in times of digitization. Based on current examples, we identify and describe characterizations of technology entrepreneurship, digital techno- logy...... entrepreneurship, and digital entrepreneurship. With this new delineation of terms, we would like to foster discussion between researchers, entrepreneurs, and policy makers on the impact of digitization on entrepreneurship, and set a future research agenda....

  2. Transformation of Digital Ecosystems

    DEFF Research Database (Denmark)

    Henningsson, Stefan; Hedman, Jonas

    2014-01-01

    the Digital Ecosystem Technology Transformation (DETT) framework for explaining technology-based transformation of digital ecosystems by integrating theories of business and technology ecosystems. The framework depicts ecosystem transformation as distributed and emergent from micro-, meso-, and macro- level......In digital ecosystems, the fusion relation between business and technology means that the decision of technical compatibility of the offering is also the decision of how to position the firm relative to the coopetive relations that characterize business ecosystems. In this article we develop...... coopetition. The DETT framework consists an alternative to the existing explanations of digital ecosystem transformation as the rational management of one central actor balancing ecosystem tensions. We illustrate the use of the framework by a case study of transformation in the digital payment ecosystem...

  3. The digital spine

    DEFF Research Database (Denmark)

    Ebbesen, Toke Riis

    2019-01-01

    In the words of the Oxford English Dictionary, a book is 'a portable volume consisting of a series of written, printed, or illustrated pages bound together for ease of reading' (‘book, n.’nd). Yet, the world of books isn’t what it used to be. If differences between media are material differences...... analyze books as digital or even 'post-digital' artifacts (Cramer 2014), while preserving the material dimension of the book artifact. In other words: is there is such a thing as a (post-)digital spine, and how can it be described? This article outlines an answer to this question within an inferential...... (Seiter 2015), and books are produced, distributed and read on various digital media and devices, it is no longer possible to understand digital books on the basis of the material and syntactical features of the codex artifact. It then becomes important to discuss how to conceptualize and subsequently...

  4. Digital Tectonic Tools

    DEFF Research Database (Denmark)

    Schmidt, Anne Marie Due

    2005-01-01

    Tectonics has been an inherent part of the architectural field since the Greek temples while the digital media is new to the field. This paper is built on the assumption that in the intermediate zone between the two there is a lot to be learned about architecture in general and the digital media...... in particular. A model of the aspects in the term tectonics – epresentation, ontology and culture – will be presented and used to discuss the current digital tools’ ability in tectonics. Furthermore it will be discussed what a digital tectonic tool is and could be and how a connection between the digital...... and tectonic could become a part of the architectural education....

  5. Concept Formation in Environmental Education: 14-Year Olds' Work on the Intensified Greenhouse Effect and the Depletion of the Ozone Layer. Research Report

    Science.gov (United States)

    Osterlind, Karolina

    2005-01-01

    A case study is presented describing the work of three pupils in the upper level of compulsory school. The pupils were learning about the intensified greenhouse effect and the depletion of the ozone layer. In their work, the need for certain domain-specific knowledge becomes apparent; for example, understanding such concepts as photosynthesis,…

  6. Influence of Intensified Supervision by Health Care Inspectorates on Online Patient Ratings of Hospitals: A Multilevel Study of More Than 43,000 Online Ratings

    NARCIS (Netherlands)

    Kool, R.B.; Kleefstra, S.M.; Borghans, H.J.; Atsma, F.; Belt, T.H. van de

    2016-01-01

    BACKGROUND: In the Netherlands, hospitals with quality or safety issues are put under intensified supervision by the Dutch Health Care Inspectorate, which involves frequent announced and unannounced site visits and other measures. Patient rating sites are an upcoming phenomenon in health care.

  7. Deconvolution of mixture spectra and increased throughput of Peptide identification by utilization of intensified complementary ions formed in tandem mass spectrometry

    DEFF Research Database (Denmark)

    Kryuchkov, Fedor; Verano-Braga, Thiago; Hansen, Thomas Aarup

    2013-01-01

    -resolution orbitrap mass spectrometry, an increase in the number of peptide identifications was obtained relative to the original CAD MS/MS spectra when intensified golden complementary (+18.6%) and CAD complementary pairs (+17.2%) were submitted to the Mascot search engine. This also exceeded the results obtained...

  8. Digital forensic standards: international progress

    CSIR Research Space (South Africa)

    Grobler, MM

    2010-05-01

    Full Text Available With the explosion of digital crime, digital forensics is more often applied. The digital forensic discipline developed rather rapidly, but up to date very little international standardization with regard to processes, procedures or management has...

  9. Computing Logarithms Digit-by-Digit

    Science.gov (United States)

    Goldberg, Mayer

    2005-01-01

    In this work, we present an algorithm for computing logarithms of positive real numbers, that bears structural resemblance to the elementary school algorithm of long division. Using this algorithm, we can compute successive digits of a logarithm using a 4-operation pocket calculator. The algorithm makes no use of Taylor series or calculus, but…

  10. Principles of synchronous digital hierarchy

    CERN Document Server

    Jain, Rajesh Kumar

    2012-01-01

    The book presents the current standards of digital multiplexing, called synchronous digital hierarchy, including analog multiplexing technologies. It is aimed at telecommunication professionals who want to develop an understanding of digital multiplexing and synchronous digital hierarchy in particular and the functioning of practical telecommunication systems in general. The text includes all relevant fundamentals and provides a handy reference for problem solving or defining operations and maintenance strategies. The author covers digital conversion and TDM principles, line coding and digital

  11. Influence of phantom and tube voltage in fluoroscopy on image intensifier (I.I.) incident dose rate

    International Nuclear Information System (INIS)

    Seguchi, Shigenobu; Ishikawa, Yoshinobu; Kuwahara, Kazuyoshi; Morita, Miki; Mizuno, Shouta; Nakamura, Akio

    1999-01-01

    We examined the influence of phantoms and tube voltage in fluoroscopy on the image intensifier (I.I.) conversion factor. We used 20-cm-thick acrylic resin, 20 mm aluminum, and 1.5 mm copper, which are generally used as phantoms in the measurement of I.I. incident dose rate. We measured I.I. incident dose rate and conversion factor under conditions in which the range of tube voltage was from 60 kV to 120 kV. The result showed that the conversion factor is influenced by the type of phantom, with copper showing the highest value, aluminum second, and acrylic the smallest under the same condition of aluminum at half value layer. It was determined that conversion factor depends on tube voltage and has peaks from 80-100 kV. The location and height of the peak are influenced by the type of phantom. Therefore, I.I. incident dose rate is influenced by both the type of phantom and tube voltage under automatic brightness control fluoroscopy. Unification of phantoms and tube voltage is necessary for long-term evaluation of I.I. incident dose rate. (author)

  12. Properties of image intensifier-related halation artifact in limited volume cone-beam CT for dental use

    International Nuclear Information System (INIS)

    Hirukawa, Akiko; Okumura, Shinji; Matsuo, Ayae; Yokoi, Midori; Gotoh, Kenichi; Katsumata, Akitoshi; Naitoh, Munetaka; Ariji, Eiichiro

    2006-01-01

    Artifacts due to halation from an image intensifier (I.I.)/charge coupled device (CCD) system appear on limited-volume cone-beam computed tomography (CBCT). Regarding anterior tooth imaging, properties of this artifact in the geometrical relationships between field of view (FOV) and objective jaw region were studied. A water-filled plastic cylinder was used as a phantom of the head. A test object was constructed as a bone-equivalent phantom to be imaged. The test object was set in the phantom at positions corresponding to the anterior tooth arch. Position of the test object was shifted to simulate individual variations in the thickness of the labial soft tissue. Limited-volume CBCT images were acquired using a 3DX system in the various offset FOV position. The affection of an artifact was evaluated by the size of the object's image. The position of the test object in the phantom, i.e. the thickness of the labial soft tissue contributes to the intensity of artifact. However, even when the labial soft tissue was thick, affection from artifact was prominent when the FOV was set so that the image of the test object was depicted near the margin of FOV. (author)

  13. The epidemiology of Plasmodium vivax and Plasmodium falciparum malaria in China, 2004-2012: from intensified control to elimination.

    Science.gov (United States)

    Zhang, Qian; Lai, Shengjie; Zheng, Canjun; Zhang, Honglong; Zhou, Sheng; Hu, Wenbiao; Clements, Archie C A; Zhou, Xiao-Nong; Yang, Weizhong; Hay, Simon I; Yu, Hongjie; Li, Zhongjie

    2014-11-03

    In China, the national malaria elimination programme has been operating since 2010. This study aimed to explore the epidemiological changes in patterns of malaria in China from intensified control to elimination stages. Data on nationwide malaria cases from 2004 to 2012 were extracted from the Chinese national malaria surveillance system. The secular trend, gender and age features, seasonality, and spatial distribution by Plasmodium species were analysed. In total, 238,443 malaria cases were reported, and the proportion of Plasmodium falciparum increased drastically from population. The areas affected by Plasmodium vivax malaria shrunk, while areas affected by P. falciparum malaria expanded from 294 counties in 2004 to 600 counties in 2012. This study demonstrated that malaria has decreased dramatically in the last five years, especially since the Chinese government launched a malaria elimination programme in 2010, and areas with reported falciparum malaria cases have expanded over recent years. These findings suggest that elimination efforts should be improved to meet these changes, so as to achieve the nationwide malaria elimination goal in China in 2020.

  14. Intensified training increases salivary free light chains in trained cyclists: Indication that training volume increases oral inflammation.

    Science.gov (United States)

    Heaney, Jennifer L J; Killer, Sophie C; Svendsen, Ida S; Gleeson, Michael; Campbell, John P

    2018-05-01

    Periods of short-term intensified training (IT) are often used by athletes during training cycles over the season and undergoing phases of increased physical stress may impact upon the immune system. This study investigated the effects of a period of IT on free light chains (FLCs) in saliva - an emerging immune biomarker of oral inflammation - and matched serum samples in well-trained athletes. It also examined if IT influences basal FLC levels and FLC flux during acute exercise. Highly trained male cyclists (n = 10) underwent a 9-day period of IT; before and after IT participants performed a 1 h time trial (TT) on a cycle ergometer, with blood and saliva samples collected pre- and post-exercise. FLCs were assessed in serum and saliva, and IgG, IgA, IgM and creatinine were also measured in serum. Weekly training volume increased by 143% (95% CI 114-172%), p training. Following IT, the cyclists demonstrated higher salivary FLC levels. Both salivary lambda FLC concentrations (p training, and we show for the first time that FLCs may have utility as a marker of exercise stress and oral health status. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. ALGORITHM OF DETERMINATION OF POWER AND ENERGY INDEXES OF SCREW INTENSIFIER ON THE BULLDOZER WORKING EQUIPMENT AT TRENCH REFILLINGS

    Directory of Open Access Journals (Sweden)

    KROL R. N.

    2016-03-01

    Full Text Available Raising of problem. A bulldozer work at trench refilings is conducted by cyclic, machine shuttle motions that increases a right-of-way; increasing of time charges, fuel and labour by the side of the continuous refilling method. Besides the indicated defects gets worse also the quality of the trench refilling: the uneven soil output into a trench with large portions results the damages of pipes isolation and emptinesses formation, in consequence  settling and washing of soil. A bulldozer with the screw intensifier (SI, is deprived lacks of an odinary bulldozer  moving along a trench, it moves the loose soil that does not fall on a pipeline, but rolles on it. Thus the circuitous speed of a cutting edge of SI exceeds the speed of the base machine moving that provides the strong soil treatment (before dispersion before output into a trench. Purpose. The algorithm development of the rotational moment determination on the SI driveshaft, the consumable energy, the energy intensity and the working process productivity of the reverse trench refillings depending on physical and mechanical properties of soil, geometrical parameters of SI and bulldozer optimal speed. Conclusion. The developed algorithm allows to define that at the fixed value of the rotational speed the rotational moment and indicated efficiency of SI at the optimum speed increasing of the base machine change on a linear law; the optimum speed change of the base machine practically does not influence on the energy intensity at the considered change of the rotational speed .

  16. The potential to intensify sulforaphane formation in cooked broccoli (Brassica oleracea var. italica) using mustard seeds (Sinapis alba).

    Science.gov (United States)

    Ghawi, Sameer Khalil; Methven, Lisa; Niranjan, Keshavan

    2013-06-01

    Sulforaphane, a naturally occurring cancer chemopreventive, is the hydrolysis product of glucoraphanin, the main glucosinolate in broccoli. The hydrolysis requires myrosinase isoenzyme to be present in sufficient activity; however, processing leads to its denaturation and hence reduced hydrolysis. In this study, the effect of adding mustard seeds, which contain a more resilient isoform of myrosinase, to processed broccoli was investigated with a view to intensify the formation of sulforaphane. Thermal inactivation of myrosinase from both broccoli and mustard seeds was studied. Thermal degradation of broccoli glucoraphanin was investigated in addition to the effects of thermal processing on the formation of sulforaphane and sulforaphane nitrile. Limited thermal degradation of glucoraphanin (less than 12%) was observed when broccoli was placed in vacuum sealed bag (sous vide) and cooked in a water bath at 100°C for 8 and 12 min. Boiling broccoli in water prevented the formation of any significant levels of sulforaphane due to inactivated myrosinase. However, addition of powdered mustard seeds to the heat processed broccoli significantly increased the formation of sulforaphane. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  17. Intensifying radiation induced grafting of 4-vinylpyridine/glycidyl methacrylate mixtures onto poly(ethylene-co-tetrafluoroethylene) films using ultrasound

    International Nuclear Information System (INIS)

    Nasef, Mohamed Mahmoud; Sithambaranathan, Paveswari; Ahmad, Arshad; Abouzari-lotf, Ebrahim

    2017-01-01

    A new ultrasound-aided method was used to enhance grafting of 4-vinylpyridine (4-VP) and glycidyl methacrylate (GMA) monomers mixtures onto electron beam (EB) irradiated poly(ethylene-co-tetrafluoroethylene) (ETFE) film for the first time. The effects of reaction parameters such as absorbed dose, monomer concentration, reaction time on both of degree of grafting (DG) and grafting efficiency (GE) were investigated under sonication and conventional grafting at similar temperatures. Fourier transform infrared (FTIR) and atomic force microscopy (AFM) were used to monitor the impact of the applied ultrasound on composition and surfaces of the grafted films whereas 1 H-NMR was used to investigate composition of the grafting residues. The ultrasound-aided grafting of 4-VP/GMA was found to enhance both of DG% and GE remarkably. Moreover, it produced grafted ETFE films having smoother surfaces without homopolymer contamination compared to grafted films obtained from conventional grafting. The results of this study suggest that the use of ultrasound is a promising way for intensifying grafting process and improving its economy. - Highlights: • Grafting of 4-VP/GMA onto ETFE films was carried out with the aid of ultrasound. • Degree of grafting was found to be strongly dependent on reaction parameters. • Sonication remarkably enhanced the reaction kinetics and grafting efficiency. • Grafted films with smoother surfaces without homopolymer contamination were obtained. • Ultrasound aided grafting is superior to conventional one and promotes intensification.

  18. Intensified pharmaceutical care is improving immunosuppressive medication adherence in kidney transplant recipients during the first post-transplant year: a quasi-experimental study.

    Science.gov (United States)

    Joost, Robert; Dörje, Frank; Schwitulla, Judith; Eckardt, Kai-Uwe; Hugo, Christian

    2014-08-01

    Medication adherence is critical for transplant patients because the consequences of non-adherence can result in allograft loss and may be life threatening. A prospective study with 74 renal transplant recipients using a sequential control group design was performed to investigate the impact of a pharmaceutical intensified care programme led by a clinical pharmacist on daily drug adherence during the first year after renal transplantation. Thirty-nine patients of the control group received the already established standardized drug and transplant training, while 35 patients of the intensified care group (ICG) received additional inpatient and outpatient pharmaceutical care and counselling by a dedicated clinical pharmacist. Applied interventions were clustered and classified using the behaviour change technique taxonomy according to Michie. Adherence to immunosuppressive drug therapy was monitored up to 1 year using a medication event monitoring system, pill count (PC), drug holiday (DH) occurrence, Morisky questionnaire and self-report. Sixty-seven patients (35 of the standard care and 32 of the ICG) were analysed. Implementation of DA was significantly (P = 0.014) improved in patients of the ICG (91%) compared with SCG (75%) during the first year after transplantion. Daily adherence measures were already improved within 30-40 days after start of intensified patient care and continued throughout the study period. Intensified care patients also showed significantly better results for taking adherence (P = 0.006), PC (P = 0.008) and DHs (P = 0.001). The additional, intensified pharmaceutical care improved patients' medication adherence remarkably, suggesting that the applied additional care programme has the potential to improve outcomes after organ transplantation. © The Author 2014. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  19. Research on Digital Product Modeling Key Technologies of Digital Manufacturing

    Institute of Scientific and Technical Information of China (English)

    DING Guoping; ZHOU Zude; HU Yefa; ZHAO Liang

    2006-01-01

    With the globalization and diversification of the market and the rapid development of Information Technology (IT) and Artificial Intelligence (AI), the digital revolution of manufacturing is coming. One of the key technologies in digital manufacturing is product digital modeling. This paper firstly analyzes the information and features of the product digital model during each stage in the product whole lifecycle, then researches on the three critical technologies of digital modeling in digital manufacturing-product modeling, standard for the exchange of product model data and digital product data management. And the potential signification of the product digital model during the process of digital manufacturing is concluded-product digital model integrates primary features of each stage during the product whole lifecycle based on graphic features, applies STEP as data exchange mechanism, and establishes PDM system to manage the large amount, complicated and dynamic product data to implement the product digital model data exchange, sharing and integration.

  20. Digital radiography: description and user's guide

    Energy Technology Data Exchange (ETDEWEB)

    Berthel, A. [Cryospace, 78 - Les Mureaux (France); Bonin, Th. [CEA Valduc, 21 - Is-sur-Tille (France); Cadilhon, S.; Thiery, Ch. [CEA Bruyeres-le-Chatel, 91 (France); Chatellier, L. [Electricite de France (EDF-RD), Recherche et Developpement, 78 - Chatou (France); Kaftandjian, V. [Lyon Univ., INSA Lab. Controle Non Destructif par Rayonnements Ionisants (CNDRI), 69 (France); Honorat, Ph.; Torrent, J. [SNECMA, 75 - Paris (France); Le Brun, A. [Electricite de France, 78 - Chatou (France); Maglaive, J.C. [Euromev, 78 - Buc (France); Moreau, Ph. [General Electric Industrial Inspection Technologies, 69 - Limonest (France); Pettier, J.L. [CEA Cadarach, Dir. de l' Energie Nucleaire, 13 - Saint Paul lez Durance (France); Rebuffel, V. [CEA Grenoble, Lab. d' Electronique et de Technologie de l' Informatique (LETI), 38 (France); Roenelle, P. [Centre d' Etudes Techniques de l' Equipement, 69 - Bron Lyon (France); Roussilhe, J. [Carestream Health France SA, 71 - Chalon/Saone (France); Staat, St.; Tahon, M. [Cegelec, 91 - Bretigny sur Orge (France)

    2007-07-01

    The presented document arises from the work of the group 'Digital Radiography and sensors' of COFREND. It is a collective work of synthesis aimed to analyze the quality parameters of digital images influencing the answer and the diagnosis brought to a given industrial problem. Five families of digital sensors have been studied: 1. Image Intensifier coupled with CCD devices - 2. scintillators coupled with a CCD device- 3. Flat Panels with indirect conversion - 4. Flat Panels with direct electric conversion - 5. Photostimulable Storage Phosphor Screens). In particular, concerning a complete imaging chain, it deals with the notions of magnification, blur (unsharpness) (geometrical, kinetic or internal to the very sensor), noises, scattered radiation, spatial resolution, which is different from the one of analog detectors such as films, Contrast to Noise Ratio (CNR), sensitivity using IQIs, dynamic range, detection quantum efficiency, persistence and temporal resolution. This document is not a standard; it must be understood as a user's guide, and it approaches some essentials corrections to bring to a sensor in order to optimize his efficiency without losing information during the pre-processing phase in the radiographic acquisition. It also introduces some image processing tools commonly used. It can be used as a source document to the future elaboration of a standardisation document. It augurs not at all of the choice of a digital sensor with regard to the traditional radiographic film, but gives bases of reflection to a radio user for a sensible transfer from the classic radiography to the digital radiography. (authors)

  1. Deforestation intensifies hot days

    Science.gov (United States)

    Stoy, Paul C.

    2018-05-01

    Deforestation often increases land-surface and near-surface temperatures, but climate models struggle to simulate this effect. Research now shows that deforestation has increased the severity of extreme heat in temperate regions of North America and Europe. This points to opportunities to mitigate extreme heat.

  2. Intensifying the Atmospheric

    DEFF Research Database (Denmark)

    Liebst, Lasse Suonperä

    2012-01-01

    The phenomenological concept of urban atmospheres is more often applied as an aesthetic description of the metropolitan space as such. This conceptualization is supported in this paper; however, I strive to give the concept a post-phenomenological axial turn. While phenomenology, due to its under...... sufficiently intense. All things considered, the paper should be read as a sociological contribution to theoretically reconstruct the concept of urban atmospheres in the light of spatial morphology....

  3. DSA in digital replantations

    International Nuclear Information System (INIS)

    Wang Liuhong; Chao Ming; Jiang Dingyao; Zhang Guangqiang; Wu Jianjun; Chen Xianyi; Li Bin; Sun Jihong

    2008-01-01

    Objective: To assess revascularization and vessel anastomosis in digital replantations with DSA. Methods: Twelve cases of digital replantations underwent digital subtract angiography during 2 to 4 days after fingers reattachment. The vessel anastomosis, hemodynamics, stenosis and discontinuation were investigated. The unobstructed and smooth anastomosis was suggested as early stage survival of the reattached fingers, the spasm and stenosis of the reattached vessels were considered as mild vascular crisis, and the discontinuation of hemodynamics were indicated as severe vascular crisis. Results: The total 27 vessels were clearly displayed on DSA. Of these vessels, 23 vessels were unobstructed and smooth, all digits were survived. Diagnosis coincidence of early stage survival was 100% (23/23). Two vessels were obstructed, which were testified having thrombus by operation research. The other 2 vessels were spasm, the digits were also survived ultimately by expectant treatment. All 4 abnormal vessel anatomosis were found by DSA. Conclusion: DSA is important modality in assessing revascularization and blood circulation for digital replantations, guiding in dealing with the vascular crisis, and in predicting early stage survival of the reattached digits. (authors)

  4. Digital mineral logging system

    International Nuclear Information System (INIS)

    West, J.B.

    1980-01-01

    A digital mineral logging system acquires data from a mineral logging tool passing through a borehole and transmits the data uphole to an electronic digital signal processor. A predetermined combination of sensors, including a deviometer, is located in a logging tool for the acquisition of the desired data as the logging tool is raised from the borehole. Sensor data in analog format is converted in the logging tool to a digital format and periodically batch transmitted to the surface at a predetermined sampling rate. An identification code is provided for each mineral logging tool, and the code is transmitted to the surface along with the sensor data. The self-identifying tool code is transmitted to the digital signal processor to identify the code against a stored list of the range of numbers assigned to that type of tool. The data is transmitted up the d-c power lines of the tool by a frequency shift key transmission technique. At the surface, a frequency shift key demodulation unit transmits the decoupled data to an asynchronous receiver interfaced to the electronic digital signal processor. During a recording phase, the signals from the logging tool are read by the electronic digital signal processor and stored for later processing. During a calculating phase, the stored data is processed by the digital signal processor and the results are outputted to a printer or plotter, or both

  5. Comparison of various filtering methods for digital X-ray image processing

    International Nuclear Information System (INIS)

    Pfluger, T.; Reinfelder, H.E.; Dorschky, K.; Oppelt, A.; Siemens A.G., Erlangen

    1987-01-01

    Three filtering methods are explained and compared that are used for border edge enhancement of digitally processed X-ray images. The filters are compared by two examples, a radiograph of the chest, and one of the knee joint. The unsharpness mask is found to yield the best compromise between edge enhancement and image noise intensifying effect, whereas the results obtained by the high-pass filter or the Wallis filter are less good for diagnostic evaluation. The filtered images better display narrow lines, structural borders and edges, and finely spotted areas, than the original radiograph, so that diagnostic evaluation is easier after image filtering. (orig.) [de

  6. Digital Technologies as Tools of Engagement and Dissent from the Perspective of Nonprofit Sector

    Institute of Scientific and Technical Information of China (English)

    LIN Ziying

    2017-01-01

    The widely spread of the digital technologies, such as laptop and the Internet, have brought out profound changes in the economy as wel as in political and social life and intensified the interactions and communication between the state, civil society, and market. For the time being, it offered opportunities for the nonprofit sector to initiate a brand-new stage. This article aims to explore how the technology connects nonprofit sector to government and civil society and assess the impact of technology in nonprofit sector perspective by taking The Red Cross of Society of China as an example.

  7. Digital Enlightenment Yearbook 2012

    CERN Document Server

    Bus, J; Hildebrandt, M

    2012-01-01

    There have been many inevitable transformations in society due to digitization - the introduction of digital technology, including communication technology, through the Internet and its use via the Web.This book is the first Yearbook of the Digital Enlightenment Forum. Whilst it cannot cover all the many aspects which the forum encompasses, the book gives an impression of the broad spectrum of the forum and a clear picture of the multi-disciplinary nature of the issues at stake.The first paper in the book is a contribution from the father of the Web, Sir Tim Berners-Lee, and Harry Halpin. They

  8. Fast transient digitizer

    International Nuclear Information System (INIS)

    Villa, F.

    1982-01-01

    Method and apparatus for sequentially scanning a plurality of target elements with an electron scanning beam modulated in accordance with variations in a high-frequency analog signal to provide discrete analog signal samples representative of successive portions of the analog signal; coupling the discrete analog signal samples from each of the target elements to a different one of a plurality of high speed storage devices; converting the discrete analog signal samples to equivalent digital signals; and storing the digital signals in a digital memory unit for subsequent measurement or display

  9. Digital Marketing Communication

    OpenAIRE

    Margherita Corniani

    2006-01-01

    Digital marketing communication is directed to profiled targets, which are active in the communication process. Every communication flow can ask for an information answer from the market. This opportunity grants immediate feed-backs and feed-forwards, so that digital communication can be easily and cheaply measured; digital communication flows are diffused at costs that are getting lower and lower, but it asks specialized and deep competences to communication managers. The ease in the flowing...

  10. plano de Marketing Digital

    OpenAIRE

    Bento, Daniel Jorge Cunha Correia

    2015-01-01

    O projeto aqui apresentado consiste no desenvolvimento de um plano estratégico de marketing digital para o projeto Laboratório de Criação Digital (LCDPorto). O LCDPorto tem sete anos de existência, sem nunca ter definido uma estratégia de comunicação. O principal objetivo passa por aprofundar os vários temas que integram Marketing Digital, e desenvolver um plano que permita ao LCDPorto ganhar mais notoriedade pelas atividades que desenvolve e, também, obter mais público para...

  11. Transitioning to digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, F., E-mail: Francisco.Miranda@pwc.ca [Pratt & Whitney Canada, Longueuil, Quebec (Canada)

    2015-09-15

    This article provides insight on the technical and business considerations necessary to implement or to transition to digital radiography Continued refinements in digital radiography technology have resulted in significant improvements in image quality and detectability of indications. These improvements have resulted in the acceptance of the technology by users and aerospace primes for final product inspection and disposition. Digital radiography has also been identified as an interesting cost reduction initiative with the potential of providing gains in productivity through increased throughput and decreased inspection lead-times and resulting costs. (author)

  12. The Digital Marmor Parium

    OpenAIRE

    Berti, Monica

    2017-01-01

    The Digital Marmor Parium is a project of the Alexander von Humboldt Chair of Digital Humanities at the University of Leipzig (http://www.dh.uni-leipzig.de/wo/dmp). The aim of this work is to produce a new digital edition of the so called Marmor Parium (Parian Marble), which is a Hellenistic chronicle on a marble slab coming from the Greek island of Paros. The importance of the document is due to the fact that it preserves a Greek chronology (1581/80-299/98 BC) with a list of kings and archon...

  13. SHDAS Production Digitizer Evaluation.

    Energy Technology Data Exchange (ETDEWEB)

    Merchant, Bion J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    The Seismo-Hydroacoustic Data Acquisition System (SHDAS) is undergoing evaluation in preparation for its engineering, development, and deployment by the U.S Navy as an ocean bottom seismic monitoring system. At the current stage of development, the production digitizers are being evaluated to confirm their performance prior to packaging and assembly for deployment. The testing of the digitizers is being conducted at Delta Group Electronics, the digitizer fabricator, in San Diego, California, performed by Sandia National Laboratories with the assistance of Leidos and Delta Group Electronics.

  14. Advanced Digital Preservation

    CERN Document Server

    Giaretta, David

    2011-01-01

    There is growing recognition of the need to address the fragility of digital information, on which our society heavily depends for smooth operation in all aspects of daily life. This has been discussed in many books and articles on digital preservation, so why is there a need for yet one more? Because, for the most part, those other publications focus on documents, images and webpages -- objects that are normally rendered to be simply displayed by software to a human viewer. Yet there are clearly many more types of digital objects that may need to be preserved, such as databases, scientific da

  15. Digitization in Maritime Industry

    DEFF Research Database (Denmark)

    Constantiou, Ioanna; Shollo, Arisa; Kreiner, Kristian

    2017-01-01

    Digitization in the maritime industry is expected to transform businesses. The recently introduced mobile technologies in inter-organizational processes is an example of digitization in an industry which moves very slowly towards digital transformation. We focus on the influence of mobile...... technologies on control practices in inter-organizational processes related to coping with an engine failure. We collected qualitative data from in depth interviews with representatives of the involved parties. We identify organizational and behavioural challenges hindering information sharing during problem...... technologies increase information sharing and thus the efficiency of inter-organizational processes when coping with an engine failure....

  16. Digital archives. Alcune note

    Directory of Open Access Journals (Sweden)

    Francesca Zanella

    2014-12-01

    Full Text Available MoRE is a digital native museum where projects of artworks are exposed, and also a digital archive where documents about art projectsare collected. MoRE is a multi-layered platform where artists, curators, art historians confront each other collecting art projects, organizing their documentation and defining tools for the communication and surveys on the public. In this paper some critical referencesare identified, that constitute a model for the project as they reflect on the impact of the digital dimension on the transformation of the museum and archive.

  17. Digital Library and Digital Reference Service: Integration and Mutual Complementarity

    Science.gov (United States)

    Liu, Jia

    2008-01-01

    Both the digital library and the digital reference service were invented and have been developed under the networked environment. Among their intersections, the fundamental thing is their symbiotic interest--serving the user in a more efficient way. The article starts by discussing the digital library and its service and the digital reference…

  18. Digital Literacy Learning in Higher Education through Digital Storytelling Approach

    Science.gov (United States)

    Chan, Banny S. K.; Churchill, Daniel; Chiu, Thomas K. F.

    2017-01-01

    It is necessary to develop digital literacy skills with which students can communicate and express their ideas effectively using digital media. The educational sectors around the world are beginning to incorporate digital literacy into the curriculum. Digital storytelling, one of the possible classroom activities, is an approach which may help…

  19. Digitization and digital archiving a practical guide for librarians

    CERN Document Server

    Leggett, Elizabeth R

    2014-01-01

    Modern library patrons are embracing the ease with which information can be accessed digitally, and so many librarians are currently working toward making information available electronically. Digitization and Digital Archiving: A Practical Guide for Librarians is a comprehensive guide with step-by-step instructions for forming digital archives.

  20. Digital Citizenship Means Character Education for the Digital Age

    Science.gov (United States)

    Ohler, Jason

    2012-01-01

    The reality of students' cyber lives has thrust upon educators a new approach: creating character education programs tuned to digital youth that are proactive and aggressive. This will help integrate students' digital activities within the context of the communities in which they live, both local and digital. The digital age beckons a new era of…

  1. Fast digitization and digital receiver technology

    International Nuclear Information System (INIS)

    Kimball, Ralph C.

    2002-01-01

    The potentially lucrative wireless market has led to technological advances in mixed signal devices such as high speed, high resolution A/D and D/A converters. This same market has also driven the development of high performance multi-channel digital receiver and digital transmitter ICs. Similarly, advances in semiconductor processes, coupled with the need for reduced time-to-market, has led to the development of large, enhanced performance, in-circuit programmable logic devices. A review of the key characteristics of these mixed-signal, signal processing and programmable logic devices is presented. The application of these devices and technologies to the instrumentation of Accelerators and Storage Rings is discussed and presented by way of examples. Issues relating to the requirements associated with real-time processing, I/O throughput, reconfigurability, reliability, maintainability and packaging requirements are also addressed

  2. Digital literacies at school. Students' digital profiles

    Directory of Open Access Journals (Sweden)

    Valentina Pennazio

    2013-04-01

    Full Text Available L’articolo presenta una ricerca volta a focalizzare le modalità in cui la Digital Literacy si traduce a scuola. Lo studio ha inteso sottolineare le molteplici dimensioni della Digital Literacy: Information Technology Literacy; Information Literacy; Visual Literacy e Media Literacy ed è stato effettuato nelle scuole primarie e secondarie di primo grado in Liguria. Sono state organizzate settimane di attività di ricerca, analisi e rielaborazione di informazioni, in classe e in rete, individualmente e in gruppo. Dalle autovalutazione degli studenti, svolte al termine di ogni attività, sono emersi i profili digitali che gli studenti tendono ad assumere quando utilizzano le tecnologie digitali. Tali profili possono essere utilizzati dagli insegnanti per progettare in maniera più mirata e significativa le attività con le tecnologie a scuola.

  3. Digital pathology: A systematic evaluation of the patent landscape

    Directory of Open Access Journals (Sweden)

    Ioan C. Cucoranu

    2014-01-01

    , workflow, slide navigation and remote control. An increasing number of recent patents focused on computer-aided diagnosis (CAD and digital consultation networks. Conclusion: In the last 2 decades, there have been an increasing number of patents granted and patent applications filed related to digital pathology. The number of these patents quadrupled during the last decade, and this trend is predicted to intensify based on the number of patent applications already published by the USPTO.

  4. Digital pathology: A systematic evaluation of the patent landscape.

    Science.gov (United States)

    Cucoranu, Ioan C; Parwani, Anil V; Vepa, Suryanarayana; Weinstein, Ronald S; Pantanowitz, Liron

    2014-01-01

    increasing number of recent patents focused on computer-aided diagnosis (CAD) and digital consultation networks. In the last 2 decades, there have been an increasing number of patents granted and patent applications filed related to digital pathology. The number of these patents quadrupled during the last decade, and this trend is predicted to intensify based on the number of patent applications already published by the USPTO.

  5. When Forgetting Becomes Digital

    DEFF Research Database (Denmark)

    Marton, Attila; Kallinikos, Jannis

    The structure of social memory is in a process of significant change as social operations of forgetting and remembering are increasingly written in IT and mediated in digital media. Based on an in-depth case study about the digitalization of memory institutions (libraries, archives, museums......), the paper demonstrates the emergence of a digital social memory structure that stores data as a means of forgetting. Building on such a concept, we explain the shifting structure of social memory from pre-defined, taxonomic order to algorithmic computation of artefacts and ordering. Finally, we draw...... implications from our study with regards to core organizational concepts of institutions and platforms as well as broader categories of information infrastructures and a sociology of digital knowledge....

  6. TV Digital Station Transmitters

    Data.gov (United States)

    Department of Homeland Security — This file is an extract from the Consolidated Database System (CDBS) licensed by the Media Bureau. It consists of Digital Television broadcasters (see Rule Part47...

  7. Digital pulse shape discrimination

    International Nuclear Information System (INIS)

    Miller, L. F.; Preston, J.; Pozzi, S.; Flaska, M.; Neal, J.

    2007-01-01

    Pulse-shape discrimination (PSD) has been utilised for about 40 years as a method to obtain estimates for dose in mixed neutron and photon fields. Digitizers that operate close to GHz are currently available at a reasonable cost, and they can be used to directly sample signals from photomultiplier tubes. This permits one to perform digital PSD rather than the traditional, and well-established, analogous techniques. One issue that complicates PSD for neutrons in mixed fields is that the light output characteristics of typical scintillators available for PSD, such as BC501A, vary as a function of energy deposited in the detector. This behaviour is more easily accommodated with digital processing of signals than with analogous signal processing. Results illustrate the effectiveness of digital PSD. (authors)

  8. Comprehension of digital media

    International Nuclear Information System (INIS)

    Kim, Ju Hwan

    2008-11-01

    This book is divided four parts. The first part describes media and mark on sign and media, what is the sign?, interpretation of sign and semiotics. The second part is for production sign theory and origin of digital revolution such as the problem of origin of digital revolution, homogeneity of producing goods and sign : triple triangle model for production sign theory, triple triangle model for producing goods, triple triangle model of producing sign and triple triangle model of art works. The third parts deals with development of the media and meaning of digital revolution with four changes : invention of letter, appearance of printed media and establishment modernity, appearance electronic media and mess media and appearance of digital media. The last part mentions ontology of world wide web.

  9. Students’ digital learning environments

    DEFF Research Database (Denmark)

    Caviglia, Francesco; Dalsgaard, Christian; Davidsen, Jacob

    2018-01-01

    The objective of the paper is to examine the nature of students’ digital learning environments to understand the interplay of institutional systems and tools that are managed by the students themselves. The paper is based on a study of 128 students’ digital learning environments. The objectives...... used tools in the students’ digital learning environments are Facebook, Google Drive, tools for taking notes, and institutional systems. Additionally, the study shows that the tools meet some very basic demands of the students in relation to collaboration, communication, and feedback. Finally...... of the study are 1) to provide an overview of tools for students’ study activities, 2) to identify the most used and most important tools for students and 3) to discover which activities the tools are used for. The empirical study reveals that the students have a varied use of digital media. Some of the most...

  10. Digital Mammography Tomosynthesis

    International Nuclear Information System (INIS)

    Gergov, I.; Alexov, G.; Rusonov, K.

    2017-01-01

    Siemens MAMMOMAT Inspiration with Tomosynthesis enhances the diagnostic precision in mammographic screening. The apparatus has a wide-angle tomosynthesis up to 50 degrees. The Siemens breast augmentation algorithm reconstructs multiple two-dimensional breast images into three-dimensional images at the lowest doses to help detect tumors hidden from the overlapping chest tissue, allowing for a more accurate diagnosis than standard 2-dimensional digital mammography, and reducing the number of false positive results. 3D digital tomosynthesis improves the precision of detecting and diagnosing a larger number of expansive lesions, ensures better morphological mass analysis and architectural distortion, and detecting calcifications by adding digital breast tomosynthesis to the traditional two-dimensional digital mammogram of the patient. In this way, it solves the problem of overlapping parenchyma, reduces the number of unnecessary biopsies from questionable sonomammographic findings, and the need for stressful repeating procedures, which usually contributes to both better patient outcomes and cost saving. [bg

  11. Digital image processing

    National Research Council Canada - National Science Library

    Gonzalez, Rafael C; Woods, Richard E

    2008-01-01

    Completely self-contained-and heavily illustrated-this introduction to basic concepts and methodologies for digital image processing is written at a level that truly is suitable for seniors and first...

  12. Developing digital forensic governance

    CSIR Research Space (South Africa)

    Grobler, M

    2010-03-01

    Full Text Available This paper presents a Digital Forensic (DF) governance framework and its mapping on the SANS ISO/IEC 38500:2009 Corporate governance of information technology structure. DF governance assists organisations in guiding the management team...

  13. Academia Leads Digital Revolution

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ As the Chinese book publishing industry sits nervously on the edqe of possible market economy led reforms, one key area to address will be its ability to come to terms with the onset of digital publishing.

  14. Students’ digital learning environments

    DEFF Research Database (Denmark)

    Caviglia, Francesco; Dalsgaard, Christian; Davidsen, Jacob

    2018-01-01

    of the study are 1) to provide an overview of tools for students’ study activities, 2) to identify the most used and most important tools for students and 3) to discover which activities the tools are used for. The empirical study reveals that the students have a varied use of digital media. Some of the most......, the study shows that most of the important tools are not related to the systems provided by the educational institutions. Based on the study, the paper concludes with a discussion of how institutional systems connect to the other tools in the students’ practices, and how we can qualify students’ digital......The objective of the paper is to examine the nature of students’ digital learning environments to understand the interplay of institutional systems and tools that are managed by the students themselves. The paper is based on a study of 128 students’ digital learning environments. The objectives...

  15. Digital signature feasibility study

    Science.gov (United States)

    2008-06-01

    The purpose of this study was to assess the advantages and disadvantages of using digital signatures to assist the Arizona Department of Transportation in conducting business. The Department is evaluating the potential of performing more electronic t...

  16. Performing Digital Literature

    Directory of Open Access Journals (Sweden)

    Jerome Fletcher

    2015-11-01

    Full Text Available Digital literature is a complex assemblage of related elements –material, spatial, linguistic, performative, textual, cultural, social– each of which is at one time interdependent and detached. This article discusses the literary creation within the cyberculture from the performativity point of view in relation to the textual apparatus. This is done through the analysis of a selection of performances where physical corporeality has a collaborative function with the body to a greater or lesser degree. Therefore, this physical feature can not only change, but stand at three possible and hybridizable axes: 1 the digital text as protagonist, 2 the digital text as counterpart, and 3 the digital text as site.

  17. Comprehension of digital media

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ju Hwan

    2008-11-15

    This book is divided four parts. The first part describes media and mark on sign and media, what is the sign?, interpretation of sign and semiotics. The second part is for production sign theory and origin of digital revolution such as the problem of origin of digital revolution, homogeneity of producing goods and sign : triple triangle model for production sign theory, triple triangle model for producing goods, triple triangle model of producing sign and triple triangle model of art works. The third parts deals with development of the media and meaning of digital revolution with four changes : invention of letter, appearance of printed media and establishment modernity, appearance electronic media and mess media and appearance of digital media. The last part mentions ontology of world wide web.

  18. NLM Digital Collections

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Library of Medicine's (NLM) Digital Collections offers a search-based Web service that provides access to the Dublin Core metadata and full-text OCR of...

  19. Digital imaging primer

    CERN Document Server

    Parkin, Alan

    2016-01-01

    Digital Imaging targets everyyone with an interest in digital imaging, be they professional or private, who uses even quite modest equipment such as a PC, digital camera and scanner, a graphics editor such as Paint, and an inkjet printer. Uniquely, it is intended to fill the gap between highly technical texts for academics (with access to expensive equipment) and superficial introductions for amateurs. The four-part treatment spans theory, technology, programs and practice. Theory covers integer arithmetic, additive and subtractive color, greyscales, computational geometry, and a new presentation of discrete Fourier analysis; Technology considers bitmap file structures, scanners, digital cameras, graphic editors, and inkjet printers; Programs develops several processing tools for use in conjunction with a standard Paint graphics editor and supplementary processing tools; Practice discusses 1-bit, greyscale, 4-bit, 8-bit, and 24-bit images for the practice section. Relevant QBASIC code is supplied an accompa...

  20. Wastewater treatment in a compact intensified wetland system at the Badboot: a floating swimming pool in Belgium.

    Science.gov (United States)

    Van Oirschot, D; Wallace, S; Van Deun, R

    2015-09-01

    The Badboot (Dutch for swimming pool boat) is a floating swimming pool located in the city center of Antwerp in Belgium. The overall design consists of a recycled ferry boat that serves as a restaurant and next to that a newly built ship that harbours an Olympic size swimming pool, sun decks, locker rooms with showers, and a party space. A major design goal of the project was to make the ship as environmentally friendly as possible. To avoid discharge of contaminated waste water in the Antwerp docks, the ship includes onsite treatment of wastewater in a compact constructed wetland. The treatment wetland system was designed to treat wastewater from visitor locker rooms, showers, toilets, two bars, and the wastewater from the restaurant kitchen. Due to the limited space on board the ship, only 188 m(2) could be allocated to a wetland treatment system. As a result, part of the design included intensification of the wetland treatment process through the use of Forced Bed Aeration, which injects small quantities of air in a very uniform grid pattern throughout the wetland with a mechanical air compressor. The system was monitored between August 2012 and March 2013 (with additional sampling in the autumn of 2014). Flows and loads to the wetland were highly variable, but removal efficiency was extremely high; 99.5 % for chemical oxygen demand (COD), 88.6 % for total nitrogen and 97.2 % for ammonia. The treatment performance was assessed using a first-order, tanks-in-series model (the P-k-C* model) and found to be roughly equivalent to similar intensified wetlands operating in Germany. However, treatment performance was substantially better than data reported on passive wetlands, likely as a result of intensification. Even with mechanically assisted aeration, the total oxygen delivered to the treatment wetlands was insufficient to support conventional nitrification and denitrification, so it is likely that alternate nitrogen removal pathways, such as anammox, are

  1. Short-term Risk of Serious Fall Injuries in Older Adults Initiating and Intensifying Treatment with Antihypertensive Medication

    Science.gov (United States)

    Shimbo, Daichi; Bowling, C. Barrett; Levitan, Emily B.; Deng, Luqin; Sim, John J.; Huang, Lei; Reynolds, Kristi; Muntner, Paul

    2016-01-01

    Background Antihypertensive medication use has been associated with an increased risk of falls in some but not all studies. Few data are available on the short-term risk of falls following antihypertensive medication initiation and intensification. Methods and Results We examined the association between initiating and intensifying antihypertensive medication and serious fall injuries in a case-crossover study of 90,127 Medicare beneficiaries who were ≥65 years old and had a serious fall injury between July 1, 2007 and December 31, 2012, based on emergency department and inpatient claims. Antihypertensive medication initiation was defined by a prescription fill with no fills in the prior year. Intensification was defined by the addition of a new antihypertensive class, and, separately, titration by the addition of a new class or increase in dosage of a current class. Exposures were ascertained for the 15 days before the fall (case period) and six 15-day earlier periods (control periods). Overall, 272, 1508, and 3113 Medicare beneficiaries initiated, added a new class of antihypertensive medication or titrated therapy, respectively, within 15 days of their serious fall injury. The odds for a serious fall injury was increased during the 15 days following antihypertensive medication initiation [odds ratio, OR, 1.36 (95% CI 1.19, 1.55)], adding a new class [OR 1.16 (95% CI 1.10, 1.23)], and titration [OR 1.13 (95% CI 1.08, 1.18)]. These associations were attenuated beyond 15 days. Conclusions Antihypertensive medication initiation and intensification was associated with a short-term, but not long-term, increased risk of serious fall injuries among older adults. PMID:27166208

  2. Seismo-Ionospheric Coupling as Intensified EIA Observed by Satellite Electron Density and GPS-TEC Data

    Science.gov (United States)

    Ryu, K.; Jangsoo, C.; Kim, S. G.; Jeong, K. S.; Parrot, M.; Pulinets, S. A.; Oyama, K. I.

    2014-12-01

    Examples of intensified EIA features temporally and spatially related to large earthquakes observed by satellites and GPS-TEC are introduced. The precursory, concurrent, and ex-post enhancements of EIA represented by the equatorial electron density, which are thought to be related to the M8.7 Northern Sumatra earthquake of March 2005, the M8.0 Pisco earthquake of August 2007, and the M7.9 Wenchuan Earthquake of 12 May 2008, are shown with space weather condition. Based on the case studies, statistical analysis on the ionospheric electron density data measured by the Detection of Electro-Magnetic Emissions Transmitted from Earthquake Regions satellite (DEMETER) over a period of 2005-2010 was executed in order to investigate the correlation between seismic activity and equatorial plasma density variations. To simplify the analysis, three equatorial regions with frequent earthquakes were selected and then one-dimensional time series analysis between the daily seismic activity indices and the EIA intensity indices were performed for each region with excluding the possible effects from the geomagnetic and solar activity. The statistically significant values of the lagged cross-correlation function, particularly in the region with minimal effects of longitudinal asymmetry, indicate that some of the very large earthquakes with M > 7.0 in the low latitude region can accompany observable seismo-ionospheric coupling phenomena in the form of EIA enhancements, even though the seismic activity is not the most significant driver of the equatorial ionospheric evolution. The physical mechanisms of the seismo-ionospheric coupling to explain the observation and the possibility of earthquake prediction using the EIA intensity variation are discussed.

  3. A highly intensified ART regimen induces long-term viral suppression and restriction of the viral reservoir in a simian AIDS model.

    Directory of Open Access Journals (Sweden)

    Iart Luca Shytaj

    Full Text Available Stably suppressed viremia during ART is essential for establishing reliable simian models for HIV/AIDS. We tested the efficacy of a multidrug ART (highly intensified ART in a wide range of viremic conditions (10³-10⁷ viral RNA copies/mL in SIVmac251-infected rhesus macaques, and its impact on the viral reservoir. Eleven macaques in the pre-AIDS stage of the disease were treated with a multidrug combination (highly intensified ART consisting of two nucleosidic/nucleotidic reverse transcriptase inhibitors (emtricitabine and tenofovir, an integrase inhibitor (raltegravir, a protease inhibitor (ritonavir-boosted darunavir and the CCR5 blocker maraviroc. All animals stably displayed viral loads below the limit of detection of the assay (i.e. <40 RNA copies/mL after starting highly intensified ART. By increasing the sensitivity of the assay to 3 RNA copies/mL, viral load was still below the limit of detection in all subjects tested. Importantly, viral DNA resulted below the assay detection limit (<2 copies of DNA/5*10⁵ cells in PBMCs and rectal biopsies of all animals at the end of the follow-up, and in lymph node biopsies from the majority of the study subjects. Moreover, highly intensified ART decreased central/transitional memory, effector memory and activated (HLA-DR⁺ effector memory CD4⁺ T-cells in vivo, in line with the role of these subsets as the main cell subpopulations harbouring the virus. Finally, treatment with highly intensified ART at viral load rebound following suspension of a previous anti-reservoir therapy eventually improved the spontaneous containment of viral load following suspension of the second therapeutic cycle, thus leading to a persistent suppression of viremia in the absence of ART. In conclusion, we show, for the first time, complete suppression of viral load by highly intensified ART and a likely associated restriction of the viral reservoir in the macaque AIDS model, making it a useful platform for testing

  4. Advanced digital optical communications

    CERN Document Server

    Binh, Le Nguyen

    2015-01-01

    This book provides a fundamental understanding of digital communication applications in optical communication technologies. Emphasizing operation principles versus mathematical analysis, the Second Edition includes new coverage of superchannel optical transmission systems, metropolitan and long-haul optical systems and networks, and Nyquist pulse shaping and high spectral efficiency of optical transmission systems, as well as new homework problems and examples. Featuring theoretical foundations as well as practical case studies, the text focuses on enhancements to digital technologies that are

  5. Digital Communication and Modulation

    DEFF Research Database (Denmark)

    Sørensen, John Aasted

    2010-01-01

    Fundamental principles in modern digital communication system like modems and wire- and wireless transmission over physical channels. Class room sessions and projects. Semester: Spring 2010 Extent: 7.5 ects Class size: 9......Fundamental principles in modern digital communication system like modems and wire- and wireless transmission over physical channels. Class room sessions and projects. Semester: Spring 2010 Extent: 7.5 ects Class size: 9...

  6. Digital Communication and Modulation

    DEFF Research Database (Denmark)

    Sørensen, John Aasted

    2010-01-01

    Fundamental principles in modern digital communication system like modems and wire- and wireless transmission over physical channels. Class room sessions and projects. Semester: Autumn 2010 Extent: 7.5 ects Class size: 18......Fundamental principles in modern digital communication system like modems and wire- and wireless transmission over physical channels. Class room sessions and projects. Semester: Autumn 2010 Extent: 7.5 ects Class size: 18...

  7. Strategies in digital marketing

    OpenAIRE

    Robert DRAGOMIR; Mihai ANDRONIE

    2017-01-01

    The present paper deals with digital marketing. The approach into discussion is the strategies met with the concept mentioned above. Within the actual socio-economic context, the electronic equipments offer on one hand new and innovative methods for products promoting and, on the other hand new challenges for the consumers. Thus, we analysed different and major types of strategies, which have a great impact on the digital marketing.

  8. Science & Technology Digital Library

    OpenAIRE

    Solodovnik, Iryna

    2014-01-01

    This document contains information on the activities carried out within the project Science & Technology Digital Library and in particular, it describes the Metadata Core Reference Model. Metadata are strategic for semantic interoperability to and, from the repository. Metadata are essential for available and safe management of digital objects, and for their sustainability and preservation. For these reasons, the project needs to define a specific metadata model. The purpose of this document ...

  9. Introduction of digital control

    International Nuclear Information System (INIS)

    Kim, Sang Jin

    1988-01-01

    This book is one of mechatronics series. It deals with digital control, which includes what is digital control?, display way of control system, output of primary system, secondary system like example of system and display way of the system, stabilizing of control system such as method to decide stability and system out of control, displaying equation of state into vector, good control such as the right characteristic, transient behavior and design of position control system using DC servo motor.

  10. Digital academia: How higher education is affected by digital technology

    OpenAIRE

    Eriksmo, Anton; Sundberg, Johan

    2016-01-01

    Digital technology in higher education is constantly evolving. Understanding the effects of digital technology is important for higher education institutions in order to make good investments of digital technology. Previous research has focused on learning, teaching or the organization and the relation between one of these aspects and digital technology, thereby missing a broader understanding of how materiality in digital technology affects higher education. In this study themed interviews w...

  11. Adaption of the Quality Criteria Concept to Digital Radiology (invited paper)

    International Nuclear Information System (INIS)

    Busch, H.P.; Jaschke, W.

    1998-01-01

    In recent years conventional film-screen radiography has been more and more replaced by digital techniques like 'Digital Image Intensifier Radiography' and 'Digital Storage Phosphor (Selen) Radiography'. These new digital imaging methods can be used for all areas of radiography except mammography. Digital radiography offers the advantage of additional diagnostic information, digital image format, lower radiation risk to the patient and a favourable cost/benefit relation. With digital techniques, dose can be varied over a wide range without losing diagnostic information. Thus, dose can be reduced in comparison to film-screen radiography. Inadequate technique can, in certain applications, however, lead to a significant increase of dose. Therefore, special reference dose values have to be established and controlled continuously. Different possibilities of pre- and post-processing make the evaluation of image quality of digital technique more complex compared with conventional film-screen radiography. New parameters like signal to noise ratio are more appropriate in assessing image quality. However, in daily routine well known parameters like spatial resolution, contrast detectability and dose can be more easily used for the assessment of image quality of the whole imaging chain including image processing and documentation. Special guidelines for digital radiography are necessary to guarantee high image quality and to avoid overexposure and misdiagnoses. These guidelines should be based on the Quality Criteria Concept of the EC. They should include criteria for the detectability of specific anatomic details, technical parameters for good radiographic technique and imaging performance and reference dose values. Assessment of image quality by suitable phantoms and constancy testing are prerequisites for quality assurance. The activities of an European quality criteria working group in the 'Concerted Action Programme' are focused on these subjects. (author)

  12. Digital Inheritance in the Netherlands

    NARCIS (Netherlands)

    Berlee, A.

    2017-01-01

    Our accumulation of assets is increasingly digital. What happens to these digital assets upon our death? In this Country Report, the topic of a digital inheritance is discussed in the context of Dutch law. It includes general rules on succession and their application to digital assets, which

  13. The Coevolution of Digital Ecosystems

    Science.gov (United States)

    SungYong, Um

    2016-01-01

    Digital ecosystems are one of the most important strategic issues in the current digital economy. Digital ecosystems are dynamic and generative. They evolve as new firms join and as heterogeneous systems are integrated into other systems. These features digital ecosystems determine economic and technological success in the competition among…

  14. Digital tomosynthesis of the breast

    International Nuclear Information System (INIS)

    Barkhausen, Joerg; Rody, Achim; Schaefer, Fritz K.W.

    2015-01-01

    The digital tomosynthesis applies the digital image analysis and 3D technology for improves diagnostic uses. The text book on the digital tomosynthesis of the breast covers the following issues: technique of tomosynthesis, clinical significance of digital breast tomosynthesis, innovations and future developments, case studies.

  15. Digital and analog communication systems

    Science.gov (United States)

    Shanmugam, K. S.

    1979-01-01

    The book presents an introductory treatment of digital and analog communication systems with emphasis on digital systems. Attention is given to the following topics: systems and signal analysis, random signal theory, information and channel capacity, baseband data transmission, analog signal transmission, noise in analog communication systems, digital carrier modulation schemes, error control coding, and the digital transmission of analog signals.

  16. Digital imaging in health care

    International Nuclear Information System (INIS)

    1987-01-01

    This volume describes equipment for the generation and processing of digital images in medicine. Separate chapters deal with international trade i this equipment, with economic and social considerations of digital imaging, with experiences in the use and production of digital imaging equipment and with the current status and likely trends in applications of digital imaging. 84 refs, figs and tabs

  17. Future approaches to digital systems

    International Nuclear Information System (INIS)

    Woodrough, R.E.; Beckmann, E.; Jenkins, D.; Belcher, D.

    1984-01-01

    The introduction of the first digital imaging systems has led to the concept of a totally digital imaging department - the 'filmless department'. This concept and its associated network system for digital departments are briefly considered. A transducer system of scanned projection radiography with solid state detectors used in digital chest imaging is described. The principles of this transducer system are applicable to other forms of digital radiography. (U.K.)

  18. Film-screen digital radiography

    International Nuclear Information System (INIS)

    Schwenker, R.P.; Eger, H.

    1985-01-01

    The excellent performance of the digital film-screen system as a receptor for projection radiographic data is discussed. An experimental system for obtaining high quality digital radiographic data by laser scanning radiographic films is described. This system is being used to evaluate the clinical utility of various digital image processing algorithms. Future plans include an investigation of quantitative analysis of projection radiographic data. Digital data obtained by film scanning can be used with digital image archiving and communications systems. (author)

  19. A comparative study about the efficiency of several industrial radiographic intensifying screens types by evaluation factor and the equivalent penetrometer sensitivity

    International Nuclear Information System (INIS)

    Ramos, C.W.; Gante, V.; Ribeiro, L.M.

    1992-05-01

    When a x-ray or gamma-ray beam strikes a film usually less than 1% of the energy is absorbed resulting in a photographic effect. Obviously, any mean of utilizing more fully the unabsorbed percentage of energy without complicating too much the technical radiographic procedure is highly desirable. One very common procedure is to use the film between two intensifying screens. These screens have the property of emitting electrons (lead screens) or become fluorescent (fluorescent screens) when stricken by electromagnetic radiation thus resulting in a supplementary photographic action on the film emulsion. This work presents an efficiency comparison of the more usual varieties of these intensifying screens for energies of x-ray until 300 K V. (author)

  20. Clinical inertia in poorly controlled elderly hypertensive patients: a cross-sectional study in Spanish physicians to ascertain reasons for not intensifying treatment.

    Science.gov (United States)

    Gil-Guillén, Vicente; Orozco-Beltrán, Domingo; Carratalá-Munuera, Concepción; Márquez-Contreras, Emilio; Durazo-Arvizu, Ramón; Cooper, Richard; Pertusa-Martínez, Salvador; Pita-Fernandez, Salvador; González-Segura, Diego; Martin-de-Pablo, José Luis; Pallarés, Vicente; Fernández, Antonio; Redón, Josep

    2013-06-01

    Clinical inertia, the failure of physicians to initiate or intensify therapy when indicated, is a major problem in the management of hypertension and may be more prevalent in elderly patients. Overcoming clinical inertia requires understanding its causes and evaluating certain factors, particularly those related to physicians. The objective of our study was to determine the rate of clinical inertia and the physician-reported reasons for it. An observational, cross-sectional, multi-center study was carried out in a primary care setting. We included 512 physicians, with a consecutive sampling of 1,499 hypertensive patients with clinical inertia. Clinical inertia was defined when physicians did not modify treatment despite knowing that the therapeutic target had not been reached. Clinical inertia was considered to be justified (JCI) when physicians provided an explanation for not intensifying treatment and as not justified (nJCI) when no reasons were given. JCI was observed in 30.1 % (95 % CI 27.8-32.4) of patients (n = 451) and nJCI in 69.9 % (95 % CI 67.6-72.2) (n = 1,058). JCI was associated with higher blood pressure (BP) values (both systolic and diastolic) and diabetes (p = 0.012) than nJCI. nJCI was associated with patients having an isolated increase of systolic or diastolic or high borderline BP values or cardiovascular disease. Physicians provided reasons for not intensifying treatment in poorly controlled patients in only 30 % of instances. Main reasons for not intensifying treatment were borderline BP values, co-morbidity, suspected white coat effect, or perceived difficulty achieving target. nJCI was associated with high borderline BP values and cardiovascular disease.