WorldWideScience

Sample records for fast wire scanner

  1. Fast and High Accuracy Wire Scanner

    CERN Document Server

    Koujili, M; Koopman, J; Ramos, D; Sapinski, M; De Freitas, J; Ait Amira, Y; Djerdir, A

    2009-01-01

    Scanning of a high intensity particle beam imposes challenging requirements on a Wire Scanner system. It is expected to reach a scanning speed of 20 m.s-1 with a position accuracy of the order of 1 μm. In addition a timing accuracy better than 1 millisecond is needed. The adopted solution consists of a fork holding a wire rotating by a maximum of 200°. Fork, rotor and angular position sensor are mounted on the same axis and located in a chamber connected to the beam vacuum. The requirements imply the design of a system with extremely low vibration, vacuum compatibility, radiation and temperature tolerance. The adopted solution consists of a rotary brushless synchronous motor with the permanent magnet rotor installed inside of the vacuum chamber and the stator installed outside. The accurate position sensor will be mounted on the rotary shaft inside of the vacuum chamber, has to resist a bake-out temperature of 200°C and ionizing radiation up to a dozen of kGy/year. A digital feedback controller allows maxi...

  2. The mechatronic design of a fast wire scanner in IHEP U-70 accelerator

    International Nuclear Information System (INIS)

    Baranov, V.T.; Makhov, S.S.; Savin, D.A.; Terekhov, V.I.

    2016-01-01

    This paper presents the mechatronic design of a fast wire scanner based on a servomotor. The design of the wire scanner is motivated by the need to measure the transverse profile of the high power proton and carbon beams at the IHEP U-70 accelerator. This paper formulates the requirements to the fast wire scanner system for the high intensity proton beam at the U-70 accelerator. The results on the design of electro-mechanical device for the wire scanner with a wire traveling speed 10–20 m/s are presented. The solution consists in a brushless servomotor and standard motor control electronics. High radiation levels in the accelerator enclosure dictate the use of a resolver as the position feedback element.

  3. The mechatronic design of a fast wire scanner in IHEP U-70 accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Baranov, V.T. [Institute for High Energy Physics in National Research Centre “Kurchatov Institute”, Protvino 142281 (Russian Federation); Makhov, S.S. [Microprivod Ltd., Moscow 111123 (Russian Federation); Savin, D.A.; Terekhov, V.I. [Institute for High Energy Physics in National Research Centre “Kurchatov Institute”, Protvino 142281 (Russian Federation)

    2016-10-11

    This paper presents the mechatronic design of a fast wire scanner based on a servomotor. The design of the wire scanner is motivated by the need to measure the transverse profile of the high power proton and carbon beams at the IHEP U-70 accelerator. This paper formulates the requirements to the fast wire scanner system for the high intensity proton beam at the U-70 accelerator. The results on the design of electro-mechanical device for the wire scanner with a wire traveling speed 10–20 m/s are presented. The solution consists in a brushless servomotor and standard motor control electronics. High radiation levels in the accelerator enclosure dictate the use of a resolver as the position feedback element.

  4. Vacuum Actuator and Controller Design for a Fast Wire Scanner

    CERN Document Server

    Dehning, B; Herranz Alvarez, J; Koujili, M; Sirvent Blasco, J L

    2012-01-01

    To cope with increasing requirements in terms of accuracy and beam intensity limits a beam wire scanner (BWS) design is under development for the CERN accelerators complex. The main parameters have been determined; the wire speed should be 20 m·s -1 when interacting with the beam and a beam width determination accuracy of 2µm under the harsh radioactive environment should be reached. To meet this goal, the proposed solution locates all moveable parts of the actuator and the angular sensors in the beam vacuum pipe in order to reduce the friction and to allow a direct position measurement. One absolute positioning sensor will be used for the brushless motor feedback and one custom, high precision incremental design will target the beam size determination. The laboratory tests set up for the actuator and the incremental sensor will be presented along with the motor control feedback loops developed with the DSpace environment using Simulink and MatLab tools. Finally, the development of the digital...

  5. A fast wire scanner, used to measure the transverse density distribution of beams circulating in an accelerator or storage ring.

    CERN Multimedia

    Maximilien Brice

    2002-01-01

    Fast wire scanners are used to measure the transverse density distribution of beams circulating in an accelerator or storage ring. In order to minimize blow-up of the beam through multiple Coulomb scattering, the wires are very thin (in the version shown here it is actually a twisted strand of carbon fibres with a total diameter of about 25 microns) and are swept through the beam at high speed (a linear motor, not mounted here, accelerates the wires to up to 20 m/s). One measures either the secondary emission current from the wire, or the signal from a scintillator/photomultiplier combination downstream from the wire scanner receiving the shower from nuclear reactions of beam particles with the wire nuclei. There are four such fast wire scanners in the 26 GeV PS and eight in the 1.4 GeV Booster.

  6. Mechanical optimisation of a high-precision fast wire scanner at CERN

    CERN Document Server

    Samuelsson, Sebastian; Veness, Raymond

    Wire scanners are instruments used to measure the transverse beam prole in particle accelerators by passing a thin wire through the particle beam. To avoid the issues of vacuum leakage through the bellows and wire failure related to current designs of wire scanners, a new concept for a wire scanner has been developed at CERN. This design has all moving parts inside the beam vacuum and has a nominal wire scanning speed of 20 m/s. The demands on the design associated with this together with the high precision requirements create a need for\

  7. Design of a high-precision fast wire scanner for the SPS at CERN

    CERN Document Server

    Veness, R; Dehning, B; Emery, J; Herranz Alvarez, J; Koujili, M; Samuelsson, S; Sirvent, J-L

    2012-01-01

    Studies are going on of a new wire scanner concept. All moving parts are inside the beam vacuum and it is specified for use in all the machines across the CERN accelerator complex. Key components have been developed and tested. Work is now focussing on the installation of a prototype for test in the Super Proton Synchrotron (SPS) accelerator. This article presents the specification of the device and constraints on the design for integration in the different accelerators at CERN. The design issues of the mechanical components are discussed and optimisation work shown. Finally, the prototype design, integrating the several components into the vacuum tank is presented.

  8. Minimisation of the wire position uncertainties of the new CERN vacuum wire scanner

    CERN Document Server

    AUTHOR|(CDS)2069346; Barjau Condomines, A

    In the next years the luminosity of the LHC will be significantly increased. This will require a much higher accuracy of beam profile measurement than actually achievable by the current wire scanner. The new fast wire scanner is foreseen to measure small emittance beams throughout the LHC injector chain, which demands a wire travelling speed up to 20 ms-1 and position measurement accuracy of the order of a few microns. The vibrations of the mechanical parts of the system, and particularly the vibrations of the thin carbon wire, were identified as the major error sources of wire position uncertainty. Therefore the understanding of the wire vibrations is a high priority for the design and operation of the new device. This document presents the work performed to understand the main causes of the wire vibrations observed in one of the existing wire scanner and the new proposed design.

  9. submitter Dynamical Models of a Wire Scanner

    CERN Document Server

    Barjau, Ana; Dehning, Bernd

    2016-01-01

    The accuracy of the beam profile measurements achievable by the current wire scanners at CERN is limited by the vibrations of their mechanical parts. In particular, the vibrations of the carbon wire represent the major source of wire position uncertainty which limits the beam profile measurement accuracy. In the coming years, due to the Large Hadron Collider (LHC) luminosity upgrade, a wire traveling speed up to 20 $m s^{−1}$ and a position measurement accuracy of the order of 1 μm will be required. A new wire scanner design based on the understanding of the wire vibration origin is therefore needed. We present the models developed to understand the main causes of the wire vibrations observed in an existing wire scanner. The development and tuning of those models are based on measurements and tests performed on that CERN proton synchrotron (PS) scanner. The final model for the (wire + fork) system has six degrees-of-freedom (DOF). The wire equations contain three different excitation terms: inertia...

  10. Wire scanner data analysis for the SSC Linac emittance measurement

    International Nuclear Information System (INIS)

    Yao, C.Y.; Hurd, J.W.; Sage, J.

    1993-07-01

    The wire scanners are designed in the SSC Linac for measurement of beam emittance at various locations. In order to obtain beam parameters from the scan signal, a data analysis program was developed that considers the problems of noise reduction, machine modeling, parameter fitting, and correction. This program is intended as a tool for Linac commissioning and also as part of the Linac control program. Some of the results from commissioning runs are presented

  11. First Experimental Results And Improvements On Profile Measurements With The Vibrating Wire Scanner

    CERN Document Server

    Arutunian, S G; Dobrovolski, N M; Mailian, M R; Soghoyan, H E; Vasiniuk, I E

    2003-01-01

    The paper presents the first experimental results of transverse profile scans using a wire scanner based on a vibrating wire (vibrating wire scanner - VWS). The measurements were performed at the injector electron beam (6 nA) of the Yerevan synchrotron. The beam profile information is obtained by measuring the wire natural oscillations that depend on the wire temperature. This first experiments on weak electron beam proved this new method as a very sensitive tool, even suitable for tail measurements. Additional, improvements were tested to overcome some problems connected with signal conditioning and signal transfer in the presence of electromagnetic noise. As a result the noises were neatly separated and reduced. A mathematical method for rejection of distorted data was developed. Experiments with the scanner at the PETRA accelerator at DESY are planned for measurements of beam tails.

  12. An X-ray scanner for wire chambers

    Science.gov (United States)

    Akesson, T.; Arik, E.; Assamagan, K.; Baker, K.; Benjamin, D.; Bertelsen, H.; Bytchkov, V.; Callahan, J.; Capeans-Garrido, M.; Catinaccio, A.; Cetin, A.; Cwetanski, P.; Danielsson, H.; Dittus, F.; Dolgoshein, B.; Dressnandt, N.; Ebenstein, W. L.; Eerola, P.; Farthouat, P.; Froidevaux, D.; Grichkevitch, Y.; Hajduk, Z.; Hansen, J. R.; Keener, P. K.; Kekelidze, G.; Konovalov, S.; Kowalski, T.; Kramarenko, V. A.; Kruger, K.; Lundberg, B.; Luehring, F.; Manara, A.; McFarlane, K.; Mitsou, V. A.; Morozov, S.; Muraviev, S.; Nadtochy, A.; Newcomer, F. M.; Olszowska, J.; Ogren, H.; Oh, S. H.; Peshekhonov, V.; Price, M.; Rembser, C.; Romaniouk, A.; Rust, D. R.; Schegelsky, V.; Sapinski, M.; Shmeleva, A.; Smirnov, S.; Smirnova, L. N.; Sosnovtsev, V.; Soutchkov, S.; Spiridenkov, E.; Tikhomirov, V.; VanBerg, R.; Vassilakopoulos, V.; Wang, C.; Williams, H. H.

    2003-07-01

    The techniques to measure the position of sense wires and field wires, the gas gain and the gas flow rate inside wire chambers using a collimated and filtered X-ray beam are reported. Specific examples are given using barrel modules of the Transition Radiation Tracker of the ATLAS experiment.

  13. A fast ADC scanner for multiparameter nuclear physics experiments

    International Nuclear Information System (INIS)

    Midttun, G.; Ingebretsen, F.; Holt, K.; Skaali, B.

    1983-04-01

    A fast readout system for multiparameter experiments in nuclear physics is described. The central part of the CAMAC aquisition hardware is an ADC scanner module. The scanner incorporates a new arbitration logic and direct memory access for simultaneous transfer of singles and correlated data. Together with specially designed ADC interfaces the system can be set up for any configuration of singles and multiparameter events from 1 up to 15 ADC's in one crate

  14. A high resolution wire scanner beam profile monitor with a microprocessor data acquisition system

    International Nuclear Information System (INIS)

    Cutler, R.I.; Mohr, D.L.; Whittaker, J.K.; Yoder, N.R.

    1983-01-01

    A beam profile monitor has been constructed for the NBS-LANL Racetrack Microtron. The monitor consists of two perpendicular 30 μm diameter carbon wires that are driven through an electron beam by a pneumatic actuator. A long-lifetime, electroformed nickel bellows is used for the linear-motion vacuum feedthrough. Secondary emission current from the wires and a signal from a transducer measuring the position of the wires are simultaneously digitized by a microprocessor to yield beam current density profiles in two dimensions. The wire scanner is designed for use with both pulsed and cw beams

  15. Feasibility studies on the direct wire readout on wire scanners in electron accelerators; Durchfuehrbarkeitsstudien zur direkten Drahtauslese an Wirescannern in Elektronen-Beschleunigern

    Energy Technology Data Exchange (ETDEWEB)

    Markert, Michael

    2010-10-15

    This bachelor thesis deals essentially with the signal processing of a so-called wire scanner, a special monitor, which comes to application in the beam diagnostics of particle accelerators. In this direct wire readout the voltage signal, which is induced by the particle beam in the measurement wire of the wire scanner, shall be directly read out. The aim of this thesis is to show fundamental considerations and perform studies, which study, whether and how in the future by means of a suited data transmission as well as readout electronics conclusion on the most important parameters of the beam, like position and profile, are possible. The measurement system presented here is divided in three main components: Signal measurement, signal preparation, and signal stretching. A suited test facility was developed and is presented in detail, in which then all components, like for instance the transmission cables, the wire-scanner fork, and the developed measurement circuit, are studied, which are of importance for a faultless signal transmission and presentation. Extensive measurements on the single components, as well as calculations for the signal transmission on and in the wire scanner were performed, whereby a good agreement could be found. Thereafter a comparison and a selection of the component used in this project were made. Furthermore improvement proposals, new constructions, and outlooks are presented, which could be of importance in further works.

  16. Software Development for a CompactRIO-Based Wire Scanner Control and Data Acquisition System

    International Nuclear Information System (INIS)

    Sedillo, James Daniel

    2012-01-01

    The Beam Diagnostics and Instrumentation Team at the Los Alamos Neutron Science Center is developing a wire scanner data acquisition and control system with a National Instrument's compactRIO at its core. For this application, the compactRIO controller not only requires programming the FPGA and RT computer internal to the compactRIO, but also requires programming a client computer and a touch panel display. This article will summarize the hardware interfaces and describe the software design approach utilized for programming and interfacing the four systems together in order to fulfill the design requirements and promote reliable interoperability.

  17. A real-time FPGA based monitoring and fault detection processing system for the Beam Wire Scanner instruments at CERN

    CERN Document Server

    AUTHOR|(CDS)2070252; Tognolini, Maurizio; Zamantzas, Christos

    The CERN Beam Instrumentation group (BE-BI) is designing a new generation of an instrument called Beam Wire Scanner (BWS). This system uses an actuator to move a very thin wire through a particle beams, back and forth with a movement stroke of pi [rad]. To achieve very fast speed when touching the particle beam with such a small stroke, large torque is applied while the expected smoothness of the displacement is crucial. This system relies on a resolver to determine the angular position and power correctly its Permanent Magnet Synchronous Motor (PMSM). In 2016, a failure of the position acquisition chain has highlighted the severe consequences of such problem, which resulted by 24 hours downtime of the Super Proton Synchrotron (SPS) accelerator with significant financial consequences. This work mitigates this single failure point by taking advantage of the existing redundancy in the sensors embedded on the system. The resolver is compared to two Incremental Optical Position Sensor (IOPS) developed in-house ...

  18. Performance assesment of pre-series beam wire scanner prototypes for the LHC injectors upgrade

    CERN Document Server

    AUTHOR|(CDS)2243534

    The BEAM department (BE), is in charge of the development and operation of the accelerator components. Inside this department, the Beam Instrumentation group (BE-BI) works on the instruments that allows the operators and scientists to observe the accelerated beam and its characteristics. Finally, the Profile Measurement section (BE-BI-PM) deals with all the instruments capable of measuring the particles transverse distribution (often called transverse beam profile). Among the different systems developed and maintained by the section, the Beam Wire Scanners (BWS) are particularly relevant, because ensures the accurate beam profile measurements in all the circular accelerators and serves as calibration for other instruments. A total of 31 BWS are installed in the PS, PSB, SPS and LHC (see Fig. 1 to recognize the different accelerators). All of these instruments present a different design, depending on their location, and are not satisfying the HL-LHC needs. In order to harmonize the CERN’s BWS with a single d...

  19. Fast neutron radiography scanner for the detection of contraband in air cargo containers

    International Nuclear Information System (INIS)

    Eberhardt, J.E.; Rainey, S.; Stevens, R.J.; Sowerby, B.D.; Tickner, J.R.

    2005-01-01

    There is a growing need to rapidly scan bulk air cargo for contraband such as illicit drugs and explosives. The Commonwealth Science and Industrial Research Organisation (CSIRO) have been working with Australian Customs Service to develop a scanner capable of directly scanning airfreight containers in 1-2 minutes without unpacking. The scanner combines fast neutron and gamma-ray radiography to provide high-resolution images that include information on material composition. A full-scale prototype scanner has been successfully tested in the laboratory and a commercial-scale scanner is due to be installed at Brisbane airport in 2005

  20. Design and construction of a new actuator for the LHC wire scanner

    CERN Document Server

    Koujili, Mohamed

    The LHC collides two protons beams with an energy of 7 TeV each resultingin a aimed total particle rate of about 109 Hz. The particle rateis determined by the production cross section, a natural constant and theluminosity accelerator dependent parameter describing the particle beams.The luminosity depends on the number of particles in each beam linearlyand on the transverse dimensions of the particle beam inversely. It increaseswith the particle beam density and therefore the probability of interactions.To optimize the transverse beams sizes, pro_le monitors are used to measureparameter depending changes. Within the LHC, three di_erent typesof pro_le monitors are installed: Wire scanner (WS), Synchrotron lightmonitor and Rest Gas Pro_le Monitor. The WS monitor is considered tobe the most accurate of these monitors and serves as a calibration devicefor the two others. The WS is an electro-mechanical device which measuresthe transverse beam density pro_le in an intermittent way. As the wirepasses through the be...

  1. Clinical applications of the imatron fast CT scanner

    International Nuclear Information System (INIS)

    Stanford, W.

    1986-01-01

    Utilizing three imaging modes, Cine CT has proven satisfactory in the assessment of left ventricular mass and function including ejection fractions and abnormalities of wall motion. It is helpful in documenting pericardial constrictions, as well as in assessing intracavitary tumors and thrombi. In the lungs, it is used to document AV fistulae and to evaluate the vascularity of mediastinal masses and to exclude invasion or major thoracic vessels. It can be used, as in the conventional scanner, for needle directed lung and chest well biopsies. It is frequently used in a airway studies to differentiate fixed from physiologic constrictions and to assess tracheomalacia and bronchopulmonary dysplasias. It can be used to plan radiation ports in the treatment of breast carcinoma. In the abdomen, successful applications include its use in the assessment of renal blood flow and the evaluation of cavernous hemangiomas of the liver as well as in screening of possible aortic aneurysms. In orthopedics, Cine CT is used to evaluate patellofermoral tracking in subluxations of the patella and used to evaluate subluxations and dislocations of the radio-ulnar joint. Cine CT by virtue of its speed and satisfactory spatial resolution is a significant imaging modality for evaluating the beating heart. Other applications include the evaluation of aortic aneurysms and dissections, para-aortic mass lesions, airway obstructions and patellar tracking and forearm subluxations

  2. Test Measurements of a 20 ms-1 Carbon Wire Beam Scanner

    CERN Document Server

    De Freitas, J; Emery, J; Herranz Alvarez, J F; Koujili, M; Ramos, D; Sapinski, M; Ait-Amira, Y; Djerdir, A

    2011-01-01

    This paper pre­sents the de­sign of the ac­tu­a­tor for the fast and high ac­cu­ra­cy Wire Scan­ner sys­tem. The ac­tu­a­tor con­sists of a ro­tary brushless syn­chronous motor with the per­ma­nent mag­net rotor in­stalled in­side the vac­u­um cham­ber and the sta­tor in­stalled out­side. The fork, per­ma­nent mag­net rotor and two an­gu­lar po­si­tion sen­sors are mount­ed on the same axis and lo­cat­ed in­side the beam vac­u­um cham­ber. The system has to re­sist a bake-out tem­per­a­ture of 200 C and ion­iz­ing radi­a­tion up to tenths of kGy/year. Max­i­mum wire trav­el­ling speed of 20 m/s and a po­si­tion mea­sure­ment ac­cu­ra­cy of 4 um is re­quired. Therefore, the sys­tem must avoid gen­er­at­ing vi­bra­tion and electromagnet­ic in­ter­fer­ence. A dig­i­tal feed­back con­troller will allow max­i­mum flex­i­bil­i­ty for the loop pa­ram­e­ters and feeds the 3-phase lin­ear power driv­er. The per­for­mance of the pr...

  3. Design of optimal fast scanning trajectory for the mechanical scanner of measurement instruments.

    Science.gov (United States)

    Ju, Bing-Feng; Bai, Xiaolong; Chen, Jian; Ge, Yaozheng

    2014-01-01

    This paper focuses on the design of the optimal scanning mode for the family of scanning probe microscopes. Based on different values of the maximum acceleration (deceleration) rate and maximum speed of X- and Y- axes of the mechanical scanner encountered in practice due to different mechanical design and loads, the design procedure of the optimal fast scanning mode is presented, which is found to be sensitive to the specific parameters of the scanning motion. By utilizing the simultaneous motion of the two axes, the fast raster scanning mode proposed can improve the scanning efficiency by 29% when comparing with the conventional raster (CR) scanning mode, if the scanning speeds of both axes are identical. In addition, the optimal fast mode provided by us has no effects on the image accuracy such as image degradation, image distortion when the efficiency is evaluated. No further difficulties are introduced to the control of the mechanical scanner and the data acquisition process. This optimal scanning mode is useful when the response time of the probe is very fast (such as ultrasonic probe in scanning acoustic microscope (SAM)), and the main limitations are due to the mechanical scanner. By applying different loads for both axes, the experiments with different scanning areas and scanning modes are conducted in a self-developed SAM. Experimental results coincide with the theoretical analysis and confirm the validation of our proposed optimal fast scanning mode and its superiority over the CR scanning mode. © 2013 Wiley Periodicals, Inc.

  4. Interpolation Algorithm for Fast Evaluation of EM Coupling between Wires

    NARCIS (Netherlands)

    Marasini, C.; Lepelaars, E.S.A.M.; Zwamborn, A.P.M.

    2009-01-01

    Efficient and accurate evaluation of the EM field radiated by a current flowing along a wire is essential to solve the electromagnetic coupling between arbitrary oriented wires. In this paper, a numerically efficient algorithm for the evaluation of coupling is presented. The currents along the wires

  5. Fast pyrolysis in a novel wire-mesh reactor: decomposition of pine wood and model compounds

    NARCIS (Netherlands)

    Hoekstra, E.; van Swaaij, Willibrordus Petrus Maria; Kersten, Sascha R.A.; Hogendoorn, Kees

    2012-01-01

    In fast pyrolysis, biomass decomposition processes are followed by vapor phase reactions. Experimental results were obtained in a unique wire-mesh reactor using pine wood, KCl impregnated pine wood and several model compounds (cellulose, xylan, lignin, levoglucosan, glucose). The wire-mesh reactor

  6. FPGA based fast synchronous serial multi-wire links synchronization

    Science.gov (United States)

    Pozniak, Krzysztof T.

    2013-10-01

    The paper debates synchronization method of multi-wire, serial link of constant latency, by means of pseudo-random numbers generators. The solution was designed for various families of FPGA circuits. There were debated synchronization algorithm and functional structure of parameterized transmitter and receiver modules. The modules were realized in VHDL language in a behavioral form.

  7. Normal zone origination and propagation in superconducting wire with fast changing current

    International Nuclear Information System (INIS)

    Vysotsky, V.S.; Tsikhon, V.N.

    1994-01-01

    The key to understanding the fast quench phenomenon in multistrand cables is the normal zone origination and propagation in superconducting wires with fast changing currents. Results of experiments simulating the situation in strands during fast quench development are presented. The maximum quench current, normal zone velocity, increase of current and time before quench are measured in NbTi-CuNi composite wire at different transport current ramp rates and at different initial currents. Normal zone velocity propagation depends on I(t) and I(t) only. The presence of an initial current leads to the acceleration of normal zone propagation at decreasing current. The initial current also leads to a reduction of the current increase and the time when a quench starts. The authors use the results received to explain the appearance of fast quench phenomenon in superconducting cables with insulated or highly resistive matrix strands

  8. MR-guided breast biopsy and hook wire marking using a low-field (0.23 T) scanner with optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Reinikainen, Heli; Blanco Sequeiros, Andreas M.; Ojala, Risto; Paeaekkoe, Eija; Tervonen, Osmo; Vaara, Teuvo

    2007-01-01

    The purpose of this study was to evaluate the technical feasibility of MR-guided percutaneous breast biopsy (LCNB) and breast hook wire marking in a low-field (0.23 T) MRI system with optical instrument tracking. MR-guided core biopsy and/or hook wire marking was performed on 13 lesions observable at MR imaging only. Seven breast LCNBs and 10 hook wire markings were performed under MR guidance on 11 patients. The diagnosis was confirmed by excision biopsy or mastectomy in 12 lesions and with histopathological and cytological diagnosis and 12-month clinical follow-up in one lesion. All lesions seen in the high-field scanner were also successfully identified and targeted in the low-field scanner. The following procedures were typically technically successful. There were difficulties due to unsatisfactory functioning of some core biopsy guns. Detailed description of low-field MR guidance and optical tracking in breast biopsies is provided. The procedure seems accurate and safe and provides means to obtain a histological diagnosis of a breast lesion only seen with MRI. The low-field biopsy system is comparable to the high-field MRI system. MR-compatible biopsy guns need to be improved. (orig.)

  9. Implementation of fast macromolecular proton fraction mapping on 1.5 and 3 Tesla clinical MRI scanners: preliminary experience

    Science.gov (United States)

    Yarnykh, V.; Korostyshevskaya, A.

    2017-08-01

    Macromolecular proton fraction (MPF) is a biophysical parameter describing the amount of macromolecular protons involved into magnetization exchange with water protons in tissues. MPF represents a significant interest as a magnetic resonance imaging (MRI) biomarker of myelin for clinical applications. A recent fast MPF mapping method enabled clinical translation of MPF measurements due to time-efficient acquisition based on the single-point constrained fit algorithm. However, previous MPF mapping applications utilized only 3 Tesla MRI scanners and modified pulse sequences, which are not commonly available. This study aimed to test the feasibility of MPF mapping implementation on a 1.5 Tesla clinical scanner using standard manufacturer’s sequences and compare the performance of this method between 1.5 and 3 Tesla scanners. MPF mapping was implemented on 1.5 and 3 Tesla MRI units of one manufacturer with either optimized custom-written or standard product pulse sequences. Whole-brain three-dimensional MPF maps obtained from a single volunteer were compared between field strengths and implementation options. MPF maps demonstrated similar quality at both field strengths. MPF values in segmented brain tissues and specific anatomic regions appeared in close agreement. This experiment demonstrates the feasibility of fast MPF mapping using standard sequences on 1.5 T and 3 T clinical scanners.

  10. ZnO subwavelength wires for fast-response mid-infrared detection.

    Science.gov (United States)

    Dai, Wei; Yang, Qing; Gu, Fuxing; Tong, Limin

    2009-11-23

    Room temperature operating thermal detection for mid-infrared light based on ZnO subwavelength wires has been demonstrated. Electric resistance in ZnO wires increases linearly with the intensity of incident light. Noise equivalent power (NEP) of 5.8 microW/Hz(1/2) (at 1 kHz) with typical response times as fast as 1.3 ms is obtained at 10.6-microm wavelength. The sensitivity and response time of the detector are also found to be insensitive to the ambient.

  11. Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation

    International Nuclear Information System (INIS)

    Sakhalkar, H. S.; Oldham, M.

    2008-01-01

    This study introduces a charge coupled device (CCD) area detector based optical-computed tomography (optical-CT) scanner for comprehensive verification of radiation dose distributions recorded in nonscattering radiochromic dosimeters. Defining characteristics include: (i) a very fast scanning time of ∼5 min to acquire a complete three-dimensional (3D) dataset, (ii) improved image formation through the use of custom telecentric optics, which ensures accurate projection images and minimizes artifacts from scattered and stray-light sources, and (iii) high resolution (potentially 50 μm) isotropic 3D dose readout. The performance of the CCD scanner for 3D dose readout was evaluated by comparison with independent 3D readout from the single laser beam OCTOPUS-scanner for the same PRESAGE dosimeters. The OCTOPUS scanner was considered the 'gold standard' technique in light of prior studies demonstrating its accuracy. Additional comparisons were made against calculated dose distributions from the ECLIPSE treatment-planning system. Dose readout for the following treatments were investigated: (i) a single rectangular beam irradiation to investigate small field and very steep dose gradient dosimetry away from edge effects, (ii) a 2-field open beam parallel-opposed irradiation to investigate dosimetry along steep dose gradients, and (iii) a 7-field intensity modulated radiation therapy (IMRT) irradiation to investigate dosimetry for complex treatment delivery involving modulation of fluence and for dosimetry along moderate dose gradients. Dose profiles, dose-difference plots, and gamma maps were employed to evaluate quantitative estimates of agreement between independently measured and calculated dose distributions. Results indicated that dose readout from the CCD scanner was in agreement with independent gold-standard readout from the OCTOPUS-scanner as well as the calculated ECLIPSE dose distribution for all treatments, except in regions within a few millimeters of the

  12. Design of an optical fibre based angular position sensor for wire scanners complying with ultra-high vacuum, high temperature and radiation conditions of the CERN´s accelerators

    CERN Document Server

    Sirvent Blasco, Jose Luis; Azorin Poveda, Jose Maria

    The main objective of this thesis is to design and implement the relative optical position sensor based on optical fibre, related to the new design of wire scanner, also taking into account the general specifications of the whole design of the Vacuum Wire Scanner (VWS from here in advanced). According to the limitations of the environment this sensor must work under very hard conditions and provide as much accuracy as possible, this means that all the components must be carefully selected and also rated to high temperature, ultra high vacuum and radiation environment to provide the longest life time as possible.

  13. A Novel Two-Wire Fast Readout Approach for Suppressing Cable Crosstalk in a Tactile Resistive Sensor Array

    Directory of Open Access Journals (Sweden)

    Jianfeng Wu

    2016-05-01

    Full Text Available For suppressing the crosstalk problem due to wire resistances and contacted resistances of the long flexible cables in tactile sensing systems, we present a novel two-wire fast readout approach for the two-dimensional resistive sensor array in shared row-column fashion. In the approach, two wires are used for every driving electrode and every sampling electrode in the resistive sensor array. The approach with a high readout rate, though it requires a large number of wires and many sampling channels, solves the cable crosstalk problem. We also verified the approach’s performance with Multisim simulations and actual experiments.

  14. A Novel Two-Wire Fast Readout Approach for Suppressing Cable Crosstalk in a Tactile Resistive Sensor Array.

    Science.gov (United States)

    Wu, Jianfeng; Wang, Yu; Li, Jianqing; Song, Aiguo

    2016-05-18

    For suppressing the crosstalk problem due to wire resistances and contacted resistances of the long flexible cables in tactile sensing systems, we present a novel two-wire fast readout approach for the two-dimensional resistive sensor array in shared row-column fashion. In the approach, two wires are used for every driving electrode and every sampling electrode in the resistive sensor array. The approach with a high readout rate, though it requires a large number of wires and many sampling channels, solves the cable crosstalk problem. We also verified the approach's performance with Multisim simulations and actual experiments.

  15. Design of a Piezoelectric-Driven Tilt Mirror for a Fast Laser Scanner

    Science.gov (United States)

    Park, Jung-Ho; Lee, Hu-Seung; Lee, Jae-Hoon; Yun, So-Nam; Ham, Young-Bog; Yun, Dong-Won

    2012-09-01

    Recently, laser scanners have been used for laser processing such as cutting, welding, and grooving, especially in the automotive industry. The laser scanners need a high-speed driving to minimize cracks caused by thermal shock of brittle materials. Therefore, a novel laser processing system that is composed of a laser source and a piezoelectric-driven tilt mirror to control the reflection angle of the laser beam, and a stage equipped with the tilt mirror has been investigated. In this study, a piezoelectric-driven tilt mirror is designed and analyzed for scanning performance to achieve a beam spot of 30 µm, a pattern width of 1 mm, an overlap ratio of 70% of the circle area, and a scanning speed of 1 m/s. Then, structural analysis of the tilt mirror with three piezoelectric actuators is performed to determine the maximum reflection angle and resonance frequency. Finally, a prototype tilt mirror is fabricated and its basic characteristics are experimentally investigated and discussed.

  16. Gabor-domain optical coherence microscopy with integrated dual-axis MEMS scanner for fast 3D imaging and metrology

    Science.gov (United States)

    Canavesi, Cristina; Cogliati, Andrea; Hayes, Adam; Santhanam, Anand P.; Tankam, Patrice; Rolland, Jannick P.

    2015-10-01

    Fast, robust, nondestructive 3D imaging is needed for characterization of microscopic structures in industrial and clinical applications. A custom micro-electromechanical system (MEMS)-based 2D scanner system was developed to achieve 55 kHz A-scan acquisition in a Gabor-domain optical coherence microscopy (GD-OCM) instrument with a novel multilevel GPU architecture for high-speed imaging. GD-OCM yields high-definition volumetric imaging with dynamic depth of focusing through a bio-inspired liquid lens-based microscope design, which has no moving parts and is suitable for use in a manufacturing setting or in a medical environment. A dual-axis MEMS mirror was chosen to replace two single-axis galvanometer mirrors; as a result, the astigmatism caused by the mismatch between the optical pupil and the scanning location was eliminated and a 12x reduction in volume of the scanning system was achieved. Imaging at an invariant resolution of 2 μm was demonstrated throughout a volume of 1 × 1 × 0.6 mm3, acquired in less than 2 minutes. The MEMS-based scanner resulted in improved image quality, increased robustness and lighter weight of the system - all factors that are critical for on-field deployment. A custom integrated feedback system consisting of a laser diode and a position-sensing detector was developed to investigate the impact of the resonant frequency of the MEMS and the driving signal of the scanner on the movement of the mirror. Results on the metrology of manufactured materials and characterization of tissue samples with GD-OCM are presented.

  17. Three dimensional conjugated heat transfer analysis in sodium fast reactor wire-wrapped fuel assembly

    International Nuclear Information System (INIS)

    Peniguel, C.; Rupp, I.; Juhel, JP.; Rolfo, S.; Guillaud, M.; Gervais, N.

    2009-01-01

    Fast reactors with liquid metal coolant have recently received a renewed interest owing to a more efficient usage of the primary uranium resources, and they are one of the proposal for the next Generation IV. In order to evaluate nuclear power plant design and safety, 3D analysis of the flow and heat transfer in a wire spacer fuel assembly are ongoing at EDF. The introduction of the wire wrapped spacers, helically wound along the pin axis, enhances the mixing of the coolant between sub-channels and prevents contact between the fuel pins. The mesh generation step constitutes a challenging task if a reasonable amount of cells in conjunction with a suitable spatial discretization is wanted. Several approaches have been investigated and will be presented. Quite complex global flow patterns are found using either k-ε or preferably Reynolds Stress turbulent models. Preliminary conjugated heat transfer calculations using a coupling between the finite element thermal code SYRTHES and the finite volume CFD code Code Saturne are also shown. (author)

  18. Development and evaluation of an ultra-fast ASIC for future PET scanners using TOF-capable MPPC array detectors

    International Nuclear Information System (INIS)

    Ambe, T.; Ikeda, H.; Kataoka, J.; Matsuda, H.; Kato, T.

    2015-01-01

    We developed a front-end ASIC for future PET scanners with Time-Of-Flight (TOF) capability to be coupled with 4×4 Multi-Pixel Photon Counter (MPPC) arrays. The ASIC is designed based on the open-IP project proposed by JAXA and realized in TSMC 0.35 μm CMOS technology. The circuit comprises 16-channel, low impedance current conveyors for effectively acquiring fast MPPC signals. For precise measurement of the coincidence timing of 511-keV gamma rays, the leading-edge method was used to discriminate the signals. We first tested the time response of the ASIC by illuminating each channel of a MPPC array device 3×3 mm 2 in size with a Pico-second Light Pulsar with a light emission peak of 655 nm and pulse duration of 54 ps (FWHM). We obtained 105 ps (FWHM) on average for each channel in time jitter measurements. Moreover, we compensated for the time lag of each channel with inner delay circuits and succeeded in suppressing about a 700-ps lag to only 15 ps. This paper reports TOF measurements using back-to-back 511-keV signals, and suggests that the ASIC can be a promising device for future TOF-PET scanners based on the MPPC array. - Highlights: • We developed a newly designed large-area monolithic MPPC array. • We obtained fine gain uniformity, and good energy and time resolutions when coupled to the LYSO scintillator. • We fabricated gamma-ray camera consisting of the MPPC array and the submillimeter pixelized LYSO and GGAG scintillators. • In the flood images, each crystal of scintillator matrices was clearly resolved. • Good energy resolutions for 662 keV gamma-rays for each LYSO and GGAG scintillator matrices were obtained

  19. Development of a portable and fast wire tension measurement system for MWPC construction

    Science.gov (United States)

    Pan, Jing-Hui; Ma, Chang-Li; Gong, Xue-Yu; Sun, Zhi-Jia; Wang, Yan-Feng; Yin, Chen-Yan; Gong, Lei

    2016-09-01

    In a multi-wire proportional chamber detector (MWPC), the anode and signal wires must maintain suitable tension, which is very important for the detector’s stable and accurate performance. As a result, wire tension control and measurement is essential in MWPC construction. A high pressure 3He MWPC detector is to be used as the thermal neutron detector of the multi-functional reflectometer at China Spallation Neutron Source, and in the construction of the detector, we have developed a wire tension measurement system. This system is accurate, portable and time-saving. With it, the wire tension on an anode wire plane has been tested. The measurement results show that the wire tension control techniques used in detector manufacture are reliable. Supported by National Natural Science Foundation of China (A050506), State Key Laboratory of Particle Detection and Electronics and Key Laboratory of China Academy of Engineering Physics (Y490KF40HD)

  20. A Micro-Platinum Wire Biosensor for Fast and Selective Detection of Alanine Aminotransferase.

    Science.gov (United States)

    Thuy, Tran Nguyen Thanh; Tseng, Tina T-C

    2016-05-26

    In this study, a miniaturized biosensor based on permselective polymer layers (overoxidized polypyrrole (Ppy) and Nafion(®)) modified and enzyme (glutamate oxidase (GlutOx)) immobilized micro-platinum wire electrode for the detection of alanine aminotransferase (ALT) was fabricated. The proposed ALT biosensor was measured electrochemically by constant potential amperometry at +0.7 V vs. Ag/AgCl. The ALT biosensor provides fast response time (~5 s) and superior selectivity towards ALT against both negatively and positively charged species (e.g., ascorbic acid (AA) and dopamine (DA), respectively). The detection range of the ALT biosensor is found to be 10-900 U/L which covers the range of normal ALT levels presented in the serum and the detection limit and sensitivity are found to be 8.48 U/L and 0.059 nA/(U/L·mm²) (N = 10), respectively. We also found that one-day storage of the ALT biosensor at -20 °C right after the sensor being fabricated can enhance the sensor sensitivity (1.74 times higher than that of the sensor stored at 4 °C). The ALT biosensor is stable after eight weeks of storage at -20 °C. The sensor was tested in spiked ALT samples (ALT activities: 20, 200, 400, and 900 U/L) and reasonable recoveries (70%~107%) were obtained.

  1. A Micro-Platinum Wire Biosensor for Fast and Selective Detection of Alanine Aminotransferase

    Directory of Open Access Journals (Sweden)

    Tran Nguyen Thanh Thuy

    2016-05-01

    Full Text Available In this study, a miniaturized biosensor based on permselective polymer layers (overoxidized polypyrrole (Ppy and Nafion® modified and enzyme (glutamate oxidase (GlutOx immobilized micro-platinum wire electrode for the detection of alanine aminotransferase (ALT was fabricated. The proposed ALT biosensor was measured electrochemically by constant potential amperometry at +0.7 V vs. Ag/AgCl. The ALT biosensor provides fast response time (~5 s and superior selectivity towards ALT against both negatively and positively charged species (e.g., ascorbic acid (AA and dopamine (DA, respectively. The detection range of the ALT biosensor is found to be 10–900 U/L which covers the range of normal ALT levels presented in the serum and the detection limit and sensitivity are found to be 8.48 U/L and 0.059 nA/(U/L·mm2 (N = 10, respectively. We also found that one-day storage of the ALT biosensor at −20 °C right after the sensor being fabricated can enhance the sensor sensitivity (1.74 times higher than that of the sensor stored at 4 °C. The ALT biosensor is stable after eight weeks of storage at −20 °C. The sensor was tested in spiked ALT samples (ALT activities: 20, 200, 400, and 900 U/L and reasonable recoveries (70%~107% were obtained.

  2. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  3. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  4. The TT-PET project: a thin TOF-PET scanner based on fast novel silicon pixel detectors

    Science.gov (United States)

    Bandi, Y.; Benoit, M.; Cadoux, F. R.; Forshaw, D. C.; Hänni, R.; Hayakawa, D.; Iacobucci, G.; Michal, S.; Miucci, A.; Paolozzi, L.; Ratib, O.; Ripiccini, E.; Tognina, C.; Valerio, P.; Weber, M.

    2018-01-01

    The TT-PET project aims at developing a compact Time-of-flight PET scanner with 30ps time resolution, capable of withstanding high magnetic fields and allowing for integration in a traditional MRI scanner, providing complimentary real-time PET images. The very high timing resolution of the TT-PET scanner is achieved thanks to a new generation of Silicon-Germanium (Si-Ge) amplifiers, which are embedded in monolithic pixel sensors. The scanner is composed of 16 detection towers as well as cooling blocks, arranged in a ring structure. The towers are composed of multiple ultra-thin pixel modules stacked on top of each other. Making it possible to perform depth of interaction measurements and maximize the spatial resolution along the line of flight of the two photons emitted within a patient. This will result in improved image quality, contrast, and uniformity while drastically reducing backgrounds within the scanner. Allowing for a reduction in the amount of radioactivity delivered to the patient. Due to an expected data rate of about 250 MB/s a custom readout system for high data throughput has been developed, which includes noise filtering and reduced data pressure. The realisation of a first scanner prototype for small animals is foreseen by 2019. A general overview of the scanner will be given including, technical details concerning the detection elements, mechanics, DAQ readout, simulation and results.

  5. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  6. Indirect-drive pre-compression of CH coated cone-in-shell target with guiding wire for fast ignition

    Science.gov (United States)

    Zhou, Weimin; Gu, Yuqiu; Shan, Lianqiang; Zhang, Baohan

    2013-10-01

    Compared with central ignition of laser fusion, fast ignition separates compression and ignition thus it can relax the requirements on the implosion symmetry and the driven energy. The Research Center of Laser Fusion has begun the related experimental researches on fast ignition based on SHENGUANG II laser facility. The small scale cone-in-shell target with guiding wire for fast ignition was pre-compressed by the SHENGUANG II eight 260J/2ns/3 ω laser beams indirectly since beam smoothing was not available currently. To minimize the mixing of the compressed fuel and high-Z vapor produced by the M-line emission from the gold holhraum, a 3 μm CH foil was coated on the full outer surface of the cone and guiding wire. The maximum density of the compressed cone-in-shell target 1.3 ns after the lasers' irradiation on the inside wall of hohlraum is about 5.0 g/cm3 , and the implosion velocity is close to 1.9*107 cm/s, which are well consistent with the simulation results with two-dimensional radiation hydrodynamic code. Experimental results and simulation results also demonstrated the coated CH foil could minimize the mixing effectively. By the appropriate design, target can remain robust before the maximum compression, that is, the time while the hot electrons produced by ignition laser pulse deposit energy in the compressed fuel.

  7. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  8. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  9. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  10. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  11. Simple and fast fabrication of superhydrophobic metal wire mesh for efficiently gravity-driven oil/water separation.

    Science.gov (United States)

    Song, Botao

    2016-12-15

    Superhydrophobic metal wire mesh (SMWM) has frequently been applied for the selective and efficient separation of oil/water mixture due to its porous structure and special wettability. However, current methods for the modification of metal wire mesh to be superhydrophobic suffered from problems with respect to complex experimental procedures or time-consuming process. In this study, a very simple, time-saving and single-step electrospray method was proposed to fabricate SMWM and the whole procedure required about only 2min. The morphology, surface composition and wettability of the SMWM were all evaluated, and the oil/water separation ability was further investigated. In addition, a commercial available sponge covered with SMWM was fabricated as an oil adsorbent for the purpose of oil recovery. This study demonstrated a convenient and fast method to modify the metal wire mesh to be superhydrophobic and such simple method might find practical applications in the large-scale removal of oils. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Fast pyrolysis in a novel wire-mesh reactor: design and initial results

    NARCIS (Netherlands)

    Hoekstra, E.; van Swaaij, Willibrordus Petrus Maria; Kersten, Sascha R.A.; Hogendoorn, Kees

    2012-01-01

    Pyrolysis is known to occur by decomposition processes followed by vapour phase reactions. The goal of this research is to develop a novel device to study the initial decomposition processes. For this, a novel wire-mesh reactor was constructed. A small sample (<0.1 g) was clamped between two meshes

  13. Fast and compact optical-resolution photoacoustic microscopy using a water-proofing two-axis MEMS scanner, and a step forward to clinical applications

    Science.gov (United States)

    Kim, Jin Young; Lee, Changho; Lim, Geunbae; Kim, Chulhong

    2016-03-01

    Optical-resolution photoacoustic microscopy (OR-PAM) is a novel microscopic tool to provide in vivo optically sensitive images in biomedical research. Conventional OR-PAM systems are typically slow and bulky because of the linear scanning stages with stepping motors. For practical purposes, however, fast imaging speed and small footprint are crucial. To address these issues, we have developed a real-time compact OR-PAM system equipped with a waterproof two-axis MEMS scanner. The OR-PAM system consists of key components such as an ultrasonic transducer with a bandwidth of 50 MHz, an opto-acoustic beam combiner (BC), and an MEMS scanner. These are all installed inside a small water tank, with dimensions of 30 mm × 90 mm × 30 mm along the x-, y-, and z-axes, respectively. A pulsed laser with a repetition rate of 50 kHz is confocally aligned with the photoacoustic (PA) waves in the BC to maximize the SNRs. The fast scanning ability of the MEMS scanner fully utilizes the A-scan speed of 50 kHz. For instance, the B- and C-scan imaging speeds are 125 Hz and 0.625 Hz, respectively, when the acquired PA maximum amplitude projection image has 200 × 200 pixels along the x- and y-axes, respectively. The measured lateral resolution of 3.6 μm and axial resolution of 27 μm are sufficient to resolve the small capillaries. Finally, we have successfully obtained in vivo PA images of iris microvasculatures in mice. This real-time and compact OR-PAM system is optimized to examine small animals in clinical studies.

  14. Characterization of velocity and temperature fields in a 217 pin wire wrapped fuel bundle of sodium cooled fast reactor

    International Nuclear Information System (INIS)

    Naveen Raj, M.; Velusamy, K.

    2016-01-01

    Highlights: • We simulate flow and temperature fields in fuel subassembly of fast reactor. • We perform high fidelity computations for 217 pin bundle of 7 axial pitch lengths. • We investigate transverse and axial flows in different types of subchannels. • Correlations are proposed for transverse flow, which form input for subchannel analysis. • Periodic variations of large magnitude are observed in subchannel flow rates. - Abstract: RANS based computational fluid dynamic (CFD) simulation of flow and temperature fields in a fast reactor fuel subassembly has been carried out. The sodium cooled prototype subassembly consists of 217 pins with helical wire spacers. An axial length of seven helical wire pitches has been considered for the study adopting a structured mesh having 36 million points and 84 processors in parallel. The computational model has been validated against in-house and published experimental data for friction factor and Nusselt number. Also, the transverse flow in the central subchannel and swirl flow in the peripheral subchannel are compared against reported experimental data and those computed by subchannel models. The focus of the study is investigation of transverse and axial flows in different types of subchannels. Based on the 3-dimensional CFD study, correlations have been proposed for calculation of transverse flow, which forms an important input for development of subchannel analysis codes. Periodic variations have been observed in the subchannel axial flow rates. For the subchannels located in the central region, the peak to peak variation in the axial flow rate is ∼21% and it is found to be contributed by the changes in the flow area and hydraulic resistance due to frequent passage of helical wires through the subchannel. For the subchannels located in the periphery, this variation is as high as 50%. The transverse flow in the central subchannels follows a cosine profile, for all the faces. However, there is a phase lag of 120

  15. A fast dual wavelength laser beam fluid-less optical CT scanner for radiotherapy 3D gel dosimetry I: design and development

    Science.gov (United States)

    Ramm, Daniel

    2018-02-01

    Three dimensional dosimetry by optical CT readout of radiosensitive gels or solids has previously been indicated as a solution for measurement of radiotherapy 3D dose distributions. The clinical uptake of these dosimetry methods has been limited, partly due to impracticalities of the optical readout such as the expertise and labour required for refractive index fluid matching. In this work a fast laser beam optical CT scanner is described, featuring fluid-less and dual wavelength operation. A second laser with a different wavelength is used to provide an alternative reference scan to the commonly used pre-irradiation scan. Transmission data for both wavelengths is effectively acquired simultaneously, giving a single scan process. Together with the elimination of refractive index fluid matching issues, scanning practicality is substantially improved. Image quality and quantitative accuracy were assessed for both dual and single wavelength methods. The dual wavelength scan technique gave improvements in uniformity of reconstructed optical attenuation coefficients in the sample 3D volume. This was due to a reduction of artefacts caused by scan to scan changes. Optical attenuation measurement accuracy was similar for both dual and single wavelength modes of operation. These results established the basis for further work on dosimetric performance.

  16. PS wire chamber

    CERN Document Server

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  17. Generation of fast protons by interaction of modest laser intensities with H2O 'snow' nano-wire targets

    International Nuclear Information System (INIS)

    Bruner, Nir; Schleifer, Elad; Palchan, Tala; Pikuz, Sergey A.; Eisenmann, Shmuel; Botton, Mordechai; Gordon, Dan; Zigler, Arie

    2011-01-01

    We report on the generation of protons with energies of 5.5 MeV when irradiating an H 2 O nano-wire layer grown on a sapphire plate with an intensity of 5x10 17 W/cm 2 . A theoretical model is suggested in which plasma near the tip of the wire is subject to enhanced electrical fields and protons are accelerated to several MeVs.

  18. A fast dual wavelength laser beam fluid-less optical CT scanner for radiotherapy 3D gel dosimetry II: dosimetric performance

    Science.gov (United States)

    Ramm, Daniel

    2018-02-01

    New clinical radiotherapy dosimetry systems need comprehensive demonstration of measurement quality. Practicality and reliability are other important aspects for clinical dosimeters. In this work the performance of an optical CT scanner for true 3D dosimetry is assessed using a radiochromic gel dosimeter. The fluid-less scanner utilised dual lasers to avoid the necessity for pre-irradiation scans and give greater robustness of image quality, enhancing practicality. Calibration methods using both cuvettes and reconstructed volumes were developed. Dosimetric accuracy was similar for dual and single wavelength measurements, except that cuvette calibration reliability was reduced for dual wavelength without pre-irradiation scanning. Detailed performance parameters were specified for the dosimetry system indicating the suitability for clinical use. The most significant limitations of the system were due to the gel dosimeter rather than the optical CT scanner. Quality assurance guidelines were developed to maintain dosimetry system performance in routine use.

  19. Charpak hemispherical wire chamber

    CERN Document Server

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  20. Basic Wiring.

    Science.gov (United States)

    Kaltwasser, Stan; And Others

    This module is the first in a series of three wiring publications; it serves as the foundation for students enrolled in a wiring program. It is a prerequisite to either "Residential Wiring" or "Commercial and Industrial Wiring." The module contains 16 instructional units that cover the following topics: occupational…

  1. Measurements for the radiation spectra of fast Z-pinches produced at compression of multi-wire arrays on the 'Angara-5-1' facility

    International Nuclear Information System (INIS)

    Bolkhovitinov, E.A.; Rupasov, A.A.; Shikanov, A.S.; Fedulov, M.V.; Grabovsky, E.V.; Gritsuk, A.N.; Oleinik, G.M.; Volkov, G.S.

    2010-01-01

    Complete text of publication follows. The measurements results on the radiation spectra of fast z-pinches produced at compression of cylindrical multi-wire tungsten and aluminum arrays in the experiments on a high-current 'Angara-5-1' facility are presented. Cylindrical multi-wire arrays has linear mass 200-400 μg/cm and the initial diameter 12-20 mm. The pinch current was about 3 MA with pulse duration of 140 ns and peak power 3 TW. The radiation spectra are measured within the range of 50-900 eV quanta by a spectrometer with transmission diffraction grating, where the radiation is recorded on the UF-4 X-ray film. An electromagnetic curtain shutter was used to protect the transmission grating from fast microparticles produced by the erosion of high-voltage electrodes. The radiation spectrum of 1-3 keV quanta was recorded by a convex crystal wide-range spectrometer. Total yield of the radiation was measured by a thermocouple calorimeter. The main part of the tungsten plasma radiative energy proves to correspond to the quasi-continuous spectrum within the range of 80-300 eV quanta. Measurements of the tungsten plasma radiation spectrum with spatial resolution by a pinch radius have shown that the effective transversal size (diameter) of the pinch as not higher than 1 mm. In the case of aluminum plasma an intensive linear radiation of the [H]- and [He]-like ions have been recorded along with a continuous and linear radiation of the [Li]- and [Be]-like ions with the range of 100-300 eV quanta. Spectral measurements of the aluminum plasma radiation with spatial resolution by the pinch radius have shown that the effective transversal size (diameter) of the pinch is around the value of 1.5 mm. Within the framework of the stationary collisional-radiative model, in respect of the [H]- and [He]-like ion spectral lines relative intensities, the parameters of the aluminum plasma pinch, namely, the electron temperature T e ∼ 550 eV and electron density n e ∼ 3 x 10 20 cm

  2. FAST

    DEFF Research Database (Denmark)

    Zuidmeer-Jongejan, Laurian; Fernandez-Rivas, Montserrat; Poulsen, Lars K.

    2012-01-01

    ABSTRACT: The FAST project (Food Allergy Specific Immunotherapy) aims at the development of safe and effective treatment of food allergies, targeting prevalent, persistent and severe allergy to fish and peach. Classical allergen-specific immunotherapy (SIT), using subcutaneous injections...... with aqueous food extracts may be effective but has proven to be accompanied by too many anaphylactic side-effects. FAST aims to develop a safe alternative by replacing food extracts with hypoallergenic recombinant major allergens as the active ingredients of SIT. Both severe fish and peach allergy are caused...... in depth serological and cellular immune analyses will be performed, allowing identification of novel biomarkers for monitoring treatment efficacy. FAST aims at improving the quality of life of food allergic patients by providing a safe and effective treatment that will significantly lower their threshold...

  3. Development of a dual-energy computed tomography quality control program: Characterization of scanner response and definition of relevant parameters for a fast-kVp switching dual-energy computed tomography system.

    Science.gov (United States)

    Nute, Jessica L; Jacobsen, Megan C; Stefan, Wolfgang; Wei, Wei; Cody, Dianna D

    2018-04-01

    A prototype QC phantom system and analysis process were developed to characterize the spectral capabilities of a fast kV-switching dual-energy computed tomography (DECT) scanner. This work addresses the current lack of quantitative oversight for this technology, with the goal of identifying relevant scan parameters and test metrics instrumental to the development of a dual-energy quality control (DEQC). A prototype elliptical phantom (effective diameter: 35 cm) was designed with multiple material inserts for DECT imaging. Inserts included tissue equivalent and material rods (including iodine and calcium at varying concentrations). The phantom was scanned on a fast kV-switching DECT system using 16 dual-energy acquisitions (CTDIvol range: 10.3-62 mGy) with varying pitch, rotation time, and tube current. The circular head phantom (22 cm diameter) was scanned using a similar protocol (12 acquisitions; CTDIvol range: 36.7-132.6 mGy). All acquisitions were reconstructed at 50, 70, 110, and 140 keV and using a water-iodine material basis pair. The images were evaluated for iodine quantification accuracy, stability of monoenergetic reconstruction CT number, noise, and positional constancy. Variance component analysis was used to identify technique parameters that drove deviations in test metrics. Variances were compared to thresholds derived from manufacturer tolerances to determine technique parameters that had a nominally significant effect on test metrics. Iodine quantification error was largely unaffected by any of the technique parameters investigated. Monoenergetic HU stability was found to be affected by mAs, with a threshold under which spectral separation was unsuccessful, diminishing the utility of DECT imaging. Noise was found to be affected by CTDIvol in the DEQC body phantom, and CTDIvol and mA in the DEQC head phantom. Positional constancy was found to be affected by mAs in the DEQC body phantom and mA in the DEQC head phantom. A streamlined scan protocol

  4. Development of multi-dimensional thermal hydraulic modeling using mixing factors for wire wrapped fuel pin bundles with inter-subassembly heat transfer in fast reactors

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, M.; Kamide, H.; Ohshima, H. [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1996-10-01

    Temperature distributions in fuel subassemblies of fast reactors interactively affect heat transfer from center to outer region of the core (inter-subassembly heat transfer) and cooling capability of an inter-wrapper flow, as well as maximum cladding temperature. The prediction of temperature distribution in the sub-assembly is, therefore one of the important issues for the reactor safety assessment. To treat the complex phenomena in the core, a multi-dimensional thermal hydraulic analysis is the most promising method. From the studies on the multi-dimensional thermal hydraulic modeling for the fuel sub-assemblies, the modeling have been recommended through the analysis of sodium experiments using driver subassembly test rig PLANDTL-DHX and blanket subassembly test rig CCTL-CFR. Computations of steady states experiments in the test rigs using the above modeling showed quite good agreement to the experimental data. In the present study, the use of this modeling was extended to transient analyses, and its applicability was examined. Firstly, non-dimensional parameters used to determine the mixing factors were modified from the ones based on bundle-averaged values to the ones by local values. Secondly, a new threshold function was derived and introduced to cut off the mixing factor of thermal plumes under inertia force dominant conditions. In the results of this validation, the accuracy was comparable between the modeling and the experimental instrumentation. Thus the present modeling is capable of predicting the thermal hydraulic fields of the wire wrapped fuel pin bundles with inter-subassembly heat transfer under the conditions from rated steady operations to transitions toward natural circulation decay heat removal modes. (J.P.N.)

  5. FAST

    Science.gov (United States)

    Nathavitharana, R R; Daru, P; Barrera, A E; Mostofa Kamal, S M; Islam, S; Ul-Alam, M; Sultana, R; Rahman, M; Hossain, Md S; Lederer, P; Hurwitz, S; Chakraborty, K; Kak, N; Tierney, D B; Nardell, E

    2017-09-01

    National Institute of Diseases of the Chest and Hospital, Dhaka; Bangladesh Institute of Research and Rehabilitation in Diabetes, Endocrine and Metabolic Disorders, Dhaka; and Chittagong Chest Disease Hospital, Chittagong, Bangladesh. To present operational data and discuss the challenges of implementing FAST (Find cases Actively, Separate safely and Treat effectively) as a tuberculosis (TB) transmission control strategy. FAST was implemented sequentially at three hospitals. Using Xpert® MTB/RIF, 733/6028 (12.2%, 95%CI 11.4-13.0) patients were diagnosed with unsuspected TB. Patients with a history of TB who were admitted with other lung diseases had more than twice the odds of being diagnosed with unsuspected TB as those with no history of TB (OR 2.6, 95%CI 2.2-3.0, P stakeholder engagement and laboratory capacity are important for sustainability and scalability.

  6. Non-destructive evaluation of fiber-reinforced composites with a fast 2D fiber-optic laser-ultrasound scanner

    Science.gov (United States)

    Pelivanov, Ivan; Buma, Takashi; Xia, Jinjun; Wei, Chen-Wei; Shtokolov, Alex; O'Donnell, Matthew

    2015-03-01

    Laser ultrasonic (LU) inspection represents an attractive, non-contact method to evaluate composite materials. Current non-contact systems, however, have relatively low sensitivity compared to contact piezoelectric detection. They are also difficult to adjust, very expensive, and strongly influenced by environmental noise. Here, we demonstrate that most of these drawbacks can be eliminated by combining a new generation of compact, inexpensive fiber lasers with new developments in fiber telecommunication optics and an optimally designed balanced probe scheme. In particular, a new type of a balanced fiber-optic Sagnac interferometer is presented as part of an all-optical LU pump-probe system for high speed non-destructive testing and evaluation (NDT&E) of aircraft composites. The performance of the LU system is demonstrated on a composite sample typically used in the aircraft industry. Wide-band ultrasound probe signals are generated directly at the sample surface with a pulsed diode-pumped laser delivering nanosecond laser pulses at a 1 kHz repetition rate with a pulse energy of 2 mJ. A balanced fiber-optic Sagnac interferometer is employed to detect pressure signals in a 1-10 MHz frequency range at the same point (an 8 μm focal spot) on the composite surface. A fast (up to 100 mm/s) 2D translation system is employed to move the sample during scanning and produce a complete B-scan consisting of one thousand A-scans in less than a second. The sensitivity of this system, in terms of the noise equivalent pressure, is found to be only 10 dB above the Nyquist thermal noise limit. To our knowledge, this is the best reported sensitivity for a non-contact ultrasonic detector of this dimension.

  7. Vibrating wire for beam profile scanning

    Directory of Open Access Journals (Sweden)

    S. G. Arutunian

    1999-12-01

    Full Text Available A method that measures the transverse profile (emittance of the bunch by detecting radiation arising at the scattering of the bunch on scanning wire is widely used. In this work information about bunch scattering is obtained by measuring the oscillation frequency of the tightened scanning wire. In such a way, the system of radiation (or secondary particles extraction and measurement can be removed. The entire unit consists of a compact fork with tightened wire and a scanning system. Normal oscillation frequency of a wire depends on wire tension, its geometric parameters, and, in a second approximation, its elastic characteristics. Normal oscillations are generated by interaction of an alternating current through the wire with magnetic field of a permanent magnet. In this case, it is suggested that the magnetic field of the accelerator (field of dipole magnets or quadrupole magnets be used for excitation of oscillations. The dependence of oscillation frequency on beam scattering is determined by several factors, including changes of wire tension caused by transverse force of the beam and influence of beam self-field. Preliminary calculations show that the influence of wire heating will dominate. We have studied strain gauges on the basis of vibrating wire from various materials (tungsten, beryl bronze, and niobium zirconium alloys. A scheme of normal oscillation generation by alternating current in autogeneration circuit with automatic frequency adjustment was selected. A special method of wire fixation and elimination of transverse degrees of freedom allows us to achieve relative stability better than 10^{-5} during several days at a relative resolution of 10^{-6}. Experimental results and estimates of wire heating of existing scanners show that the wire heats up to a few hundred grades, which is enough for measurements. The usage of wire of micrometer thickness diminishes the problem of wire thermalization speed during the scanning of the bunch.

  8. Characterization of a cone beam optical scanner

    International Nuclear Information System (INIS)

    Ravindran, P B; Thomas, H M

    2013-01-01

    The use of radiochromic FX gel for mapping 3D dose distribution is hampered by the diffusion of gel and the slow scanning techniques. The development of fast optical cone beam scanning has improved the chances of using radiochromic gel as a feasible dosimeter for radiotherapy applications. In this work an optical cone beam scanner has been developed in-house and its performance characteristics have been studied. The reconstructed image of the optical scanner was analyzed by studying the resolution, signal-to-noise ratio and contrast to noise ratio (CNR). The resolution of the optical cone beam CT scanner was studied by scanning a catheter of 1 mm outer diameter and the scanner was able to detect the catheter. The geometrical accuracy of the reconstruction was studied by placing catheters in spiral geometry in the gel phantom and measuring the distances. It has been observed that the in-house Optical Cone beam scanner is suitable for scanning radiochromic gels for radiotherapy applications.

  9. Scanner image quality profiling

    Science.gov (United States)

    Cui, Chengwu

    2009-01-01

    When using a document scanner, scan image quality is often unknown to the end user of the scanned image. Document scanners may employ different imaging technologies that can result in different image characteristics. Variability of scanner parts and the manufacturing process may also create variability of the scanned image quality from machine to machine. Image quality of the same scanner may also change as it ages and becomes contaminated. If the scanned image is used for human viewing, the resulting image quality variability may not be mission critical other than being a visual annoyance because the human visual system has superb adaptation and segmentation capability. However, if the scanned image is used for machine recognition or for printing, the image quality variability may become important and even mission critical. Here we propose a framework to profile the scanner image quality and tag the scanned image with the IQ profile. We review the potential quantified aspects of scan image quality and propose a method of characterization with examples.

  10. Method of the steel aluminum wires protection of air transmission lines from fast vibration damage at the output from the support clamp

    Science.gov (United States)

    Sabitov, L. S.; Kashapov, N. F.; Strelkov, Yu M.; Kuznetsov, I. L.

    2017-09-01

    Conducted theoretical research of the stress-strain state of flexible mechanical connections, the varieties of which are wires of overhead transmission lines, cable cable mounting structures, strings frequency sensors of force and small displacements at the nodes of a rigid fixing. Chosen form of nodules, a flexible mechanical connection at the nodes of the rigid fixing of the conditions of increasing resource durability, and also reduce the maximum total stresses from stretching and bending at the nodes of a rigid fixing.

  11. Void and Phase Evolution during the Processing of Bi-2212 Superconducting Wires monitored by combined fast Synchrotron Micro-tomography and X-Ray Diffraction

    CERN Document Server

    Scheuerlein, C; Scheel, M; Jiang, J; Kametani, F; Malagoli, A; Hellstrom, E E; Larbalestier, D C

    2011-01-01

    Recent study of the current-limiting mechanisms in Bi-2212 round wires has suggested that agglomeration of the residual Bi-2212 powder porosity into bubbles of filament-diameter size occurs on melting the Bi-2212 filaments. These pores introduce a major obstacle to current flow, which greatly reduces the critical current density (Jc). Here we present an in situ non-destructive tomographic and diffraction study of the changes occurring during the heat treatment of wires and starting powder, as well as a room temperature study of ex situ processed wires. The in situ through-process study shows that the agglomeration of residual porosity is more complex than previously seen. Filament changes start with coalescence of the quasi-uniform and finely divided powder porosity into lens-shaped defects at about 850 0C when the Bi-2201 impurity phase decomposes before the Bi-2212 starts to melt. These lens-shaped voids grow to bubbles of a filament diameter on melting of the Bi-2212 and continue to lengthen and then to ag...

  12. Ionization beam scanner

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Inner structure of an ionization beam scanner, a rather intricate piece of apparatus which permits one to measure the density distribution of the proton beam passing through it. On the outside of the tank wall there is the coil for the longitudinal magnetic field, on the inside, one can see the arrangement of electrodes creating a highly homogeneous transverse electric field.

  13. Automatic inspection of railway overhead wires

    NARCIS (Netherlands)

    Smorenburg, C.; Valkenburg, A.L.G. van

    1988-01-01

    For the Netherlands railway company a system for inspection of the degree of wear of the contact wires is being developed. With an active sensor the reflective under-surface of the overhead wire is illuminated with a laserbeam and reflected radiation is detected by fast CCD detectors. With the

  14. Scanner calibration revisited

    Directory of Open Access Journals (Sweden)

    Pozhitkov Alexander E

    2010-07-01

    Full Text Available Abstract Background Calibration of a microarray scanner is critical for accurate interpretation of microarray results. Shi et al. (BMC Bioinformatics, 2005, 6, Art. No. S11 Suppl. 2. reported usage of a Full Moon BioSystems slide for calibration. Inspired by the Shi et al. work, we have calibrated microarray scanners in our previous research. We were puzzled however, that most of the signal intensities from a biological sample fell below the sensitivity threshold level determined by the calibration slide. This conundrum led us to re-investigate the quality of calibration provided by the Full Moon BioSystems slide as well as the accuracy of the analysis performed by Shi et al. Methods Signal intensities were recorded on three different microarray scanners at various photomultiplier gain levels using the same calibration slide from Full Moon BioSystems. Data analysis was conducted on raw signal intensities without normalization or transformation of any kind. Weighted least-squares method was used to fit the data. Results We found that initial analysis performed by Shi et al. did not take into account autofluorescence of the Full Moon BioSystems slide, which led to a grossly distorted microarray scanner response. Our analysis revealed that a power-law function, which is explicitly accounting for the slide autofluorescence, perfectly described a relationship between signal intensities and fluorophore quantities. Conclusions Microarray scanners respond in a much less distorted fashion than was reported by Shi et al. Full Moon BioSystems calibration slides are inadequate for performing calibration. We recommend against using these slides.

  15. Noncontextual Wirings

    Science.gov (United States)

    Amaral, Barbara; Cabello, Adán; Cunha, Marcelo Terra; Aolita, Leandro

    2018-03-01

    Contextuality is a fundamental feature of quantum theory necessary for certain models of quantum computation and communication. Serious steps have therefore been taken towards a formal framework for contextuality as an operational resource. However, the main ingredient of a resource theory—a concrete, explicit form of free operations of contextuality—was still missing. Here we provide such a component by introducing noncontextual wirings: a class of contextuality-free operations with a clear operational interpretation and a friendly parametrization. We characterize them completely for general black-box measurement devices with arbitrarily many inputs and outputs. As applications, we show that the relative entropy of contextuality is a contextuality monotone and that maximally contextual boxes that serve as contextuality bits exist for a broad class of scenarios. Our results complete a unified resource-theoretic framework for contextuality and Bell nonlocality.

  16. Stretched Wire Mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Bowden, Gordon; /SLAC

    2005-09-06

    Stretched wires are beginning to play an important role in the alignment of accelerators and synchrotron light sources. Stretched wires are proposed for the alignment of the 130 meter long LCLS undulator. Wire position technology has reached sub-micron resolution yet analyses of perturbations to wire straightness are hard to find. This paper considers possible deviations of stretched wire from the simple 2-dimensional catenary form.

  17. The cobalt-60 container scanner

    International Nuclear Information System (INIS)

    Jigang, A.; Liye, Z.; Yisi, L.; Haifeng, W.; Zhifang, W.; Liqiang, W.; Yuanshi, Z.; Xincheng, X.; Furong, L.; Baozeng, G.; Chunfa, S.

    1997-01-01

    The Institute of Nuclear Energy Technology (INET) has successfully designed and constructed a container (cargo) scanner, which uses cobalt-60 of 100-300 Ci as radiation source. The following performances of the Cobalt-60 container scanner have been achieved at INET: a) IQI (Image Quality Indicator) - 2.5% behind 100 mm of steel; b) CI (Contrast Indicator) - 0.7% behind 100 mm of steel; c) SP (Steel Penetration) - 240 mm of steel; d) Maximum Dose per Scanning - 0.02mGy; e) Throughput - twenty 40-foot containers per hour. These performances are equal or similar to those of the accelerator scanners. Besides these nice enough inspection properties, the Cobalt-60 scanner possesses many other special features which are better than accelerator scanners: a) cheap price - it will be only or two tenths of the accelerator scanner's; b) low radiation intensity - the radiation protection problem is much easier to solve and a lot of money can be saved on the radiation shielding building; c) much smaller area for installation and operation; d) simple operation and convenient maintenance; e) high reliability and stability. The Cobalt-60 container (or cargo) scanner is satisfied for boundary customs, seaports, airports and railway stations etc. Because of the nice special features said above, it is more suitable to be applied widely. Its high properties and low price will make it have much better application prospects

  18. Radiographic scanner apparatus

    International Nuclear Information System (INIS)

    Wake, R.H.

    1980-01-01

    The preferred embodiment of this invention includes a hardware system, or processing means, which operates faster than software. Moreover the computer needed is less expensive and smaller. Radiographic scanner apparatus is described for measuring the intensity of radiation after passage through a planar region and for reconstructing a representation of the attenuation of radiation by the medium. There is a source which can be rotated, and detectors, the output from which forms a data line. The detectors are disposed opposite the planar region from the source to produce a succession of data lines corresponding to the succession of angular orientations of the source. There is a convolver means for convolving each of these data lines, with a filter function, and a means of processing the convolved data lines to create the representation of the radiation attenuation in the planar region. There is also apparatus to generate a succession of data lines indicating radiation attenuation along a determinable path with convolver means. (U.K.)

  19. Fast photoelectro-reduction of Cr{sup VI} over MoS{sub 2}@TiO{sub 2} nanotubes on Ti wire

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Lixia; Zheng, Xutong; Liu, Ming [High Level Laboratory of Jiangxi Province for Persistent Pollutants Control, Recycle and Reuse, Nanchang Hangkong University, Nanchang 330063 (China); Luo, Shenglian, E-mail: sllou@hnu.edu.cn [High Level Laboratory of Jiangxi Province for Persistent Pollutants Control, Recycle and Reuse, Nanchang Hangkong University, Nanchang 330063 (China); College of Material Science and Engineering, Nanchang Hangkong University, Nanchang 330063 (China); Luo, Yan [High Level Laboratory of Jiangxi Province for Persistent Pollutants Control, Recycle and Reuse, Nanchang Hangkong University, Nanchang 330063 (China); Li, Guifa [College of Material Science and Engineering, Nanchang Hangkong University, Nanchang 330063 (China)

    2017-05-05

    Highlights: • Few-layer MoS{sub 2} nanosheets decorated on the TiO{sub 2} NTAs via a facile hydrothermal method. • The composites possess a stable construction benefiting to the utilization of sunlight and electron transfer. • High concentration Cr{sup VI} can be fast reduced over MoS{sub 2}@TiO{sub 2} in the presence of appropriate LOAs and applied voltage. • Effect of LOAs, applied voltages and initial concentrations were performed. - Abstract: A stable MoS{sub 2} nanosheets@TiO{sub 2} NTAs composite was prepared via a simple hydrothermal process. Few-layer MoS{sub 2} nanosheets distributed on the TiO{sub 2} nanotube top surface and the inner walls rather than filling in the tubes, allowing abundant tubular channels open to environment and benefiting for efficient mass transport. Photocatalytic (PE) and photoelectrocatalytic (PEC) performance of the composite were evaluated on Cr{sup VI} reduction, with variable low molecule weight organic acids (LOAs) added as sacrificial electron donor to form a charge-transfer-complex (CTC) between LOAs and TiO{sub 2}/MoS{sub 2}, which is sensitive to the visible light illumination and could induce the photo-reduction of Cr{sup VI} and photo-oxidation of LOAs. The overall trend of Cr{sup VI} PEC rates are in the order as: L(+)-Tartaric acid > oxalic acid > citric acid > malic acid > amber acid, which is 103.9 > 62.5 > 31.2 > 21.6 > 2.5 mg/L min{sup −1} cm{sup −2}, respectively. The improved catalytic performance and excellent stability of the composite can be attributed to the abundant active adsorption and reaction sites on MoS{sub 2} nanosheets and the formation of a heterojunction between TiO{sub 2} and MoS{sub 2}. Moreover, the appropriate application of LOAs and voltage also have a great contribution to the utilization of sunlight and efficient separation of photogenerated carriers.

  20. Free-space wavelength-multiplexed optical scanner.

    Science.gov (United States)

    Yaqoob, Z; Rizvi, A A; Riza, N A

    2001-12-10

    A wavelength-multiplexed optical scanning scheme is proposed for deflecting a free-space optical beam by selection of the wavelength of the light incident on a wavelength-dispersive optical element. With fast tunable lasers or optical filters, this scanner features microsecond domain scan setting speeds and large- diameter apertures of several centimeters or more for subdegree angular scans. Analysis performed indicates an optimum scan range for a given diffraction order and grating period. Limitations include beam-spreading effects based on the varying scanner aperture sizes and the instantaneous information bandwidth of the data-carrying laser beam.

  1. Comparative evaluation of ultrasound scanner accuracy in distance measurement

    Science.gov (United States)

    Branca, F. P.; Sciuto, S. A.; Scorza, A.

    2012-10-01

    The aim of the present study is to develop and compare two different automatic methods for accuracy evaluation in ultrasound phantom measurements on B-mode images: both of them give as a result the relative error e between measured distances, performed by 14 brand new ultrasound medical scanners, and nominal distances, among nylon wires embedded in a reference test object. The first method is based on a least squares estimation, while the second one applies the mean value of the same distance evaluated at different locations in ultrasound image (same distance method). Results for both of them are proposed and explained.

  2. Wire bonding in microelectronics

    CERN Document Server

    Harman, George G

    2010-01-01

    Wire Bonding in Microelectronics, Third Edition, has been thoroughly revised to help you meet the challenges of today's small-scale and fine-pitch microelectronics. This authoritative guide covers every aspect of designing, manufacturing, and evaluating wire bonds engineered with cutting-edge techniques. In addition to gaining a full grasp of bonding technology, you'll learn how to create reliable bonds at exceedingly high yields, test wire bonds, solve common bonding problems, implement molecular cleaning methods, and much more. Coverage includes: Ultrasonic bonding systems and technologies, including high-frequency systems Bonding wire metallurgy and characteristics, including copper wire Wire bond testing Gold-aluminum intermetallic compounds and other interface reactions Gold and nickel-based bond pad plating materials and problems Cleaning to improve bondability and reliability Mechanical problems in wire bonding High-yield, fine-pitch, specialized-looping, soft-substrate, and extreme-temperature wire bo...

  3. Geometric calibration between PET scanner and structured light scanner

    DEFF Research Database (Denmark)

    Kjer, Hans Martin; Olesen, Oline Vinter; Paulsen, Rasmus Reinhold

    2011-01-01

    Head movements degrade the image quality of high resolution Positron Emission Tomography (PET) brain studies through blurring and artifacts. Manny image reconstruction methods allows for motion correction if the head position is tracked continuously during the study. Our method for motion tracking...... is a structured light scanner placed just above the patient tunnel on the High Resolution Research Tomograph (HRRT, Siemens). It continuously registers point clouds of a part of the patient's face. The relative motion is estimated as the rigid transformation between frames. A geometric calibration between...... the HRRT scanner and the tracking system is needed in order to reposition the PET listmode data or image frames in the HRRT scanner coordinate system. This paper presents a method where obtained transmission scan data is segmented in order to create a point cloud of the patient's head. The point clouds...

  4. Water Desalination with Wires

    NARCIS (Netherlands)

    Porada, S.; Sales, B.B.; Hamelers, H.V.M.; Biesheuvel, P.M.

    2012-01-01

    We show the significant potential of water desalination using a novel capacitive wire-based technology in which anode/cathode wire pairs are constructed from coating a thin porous carbon electrode layer on top of electrically conducting rods (or wires). By alternately dipping an array of electrode

  5. Development of scintillation materials for PET scanners

    CERN Document Server

    Korzhik, Mikhail; Annenkov, Alexander N; Borissevitch, Andrei; Dossovitski, Alexei; Missevitch, Oleg; Lecoq, Paul

    2007-01-01

    The growing demand on PET methodology for a variety of applications ranging from clinical use to fundamental studies triggers research and development of PET scanners providing better spatial resolution and sensitivity. These efforts are primarily focused on the development of advanced PET detector solutions and on the developments of new scintillation materials as well. However Lu containing scintillation materials introduced in the last century such as LSO, LYSO, LuAP, LuYAP crystals still remain the best PET species in spite of the recent developments of bright, fast but relatively low density lanthanum bromide scintillators. At the same time Lu based materials have several drawbacks which are high temperature of crystallization and relatively high cost compared to alkali-halide scintillation materials. Here we describe recent results in the development of new scintillation materials for PET application.

  6. Radiographic scanners and shutter mechanisms in CT scanners

    International Nuclear Information System (INIS)

    Braden, A.B.; Kuwik, J.J.; Taylor, S.K.; Covic, J.

    1981-01-01

    This patent claim relates especially to the design of a shutter mechanism in a CT scanner having a rotatable source of radiation and a series of stationary radiation detectors coplanar with the path of the source and spaced about the axis of rotation of the source, and only partially encircling the path of the source. (U.K.)

  7. A case study in scanner optimisation.

    Science.gov (United States)

    Dudley, N J; Gibson, N M

    2014-02-01

    Ultrasound scanner preset programmes are factory set or tailored to user requirements. Scanners may, therefore, have different settings for the same application, even on similar equipment in a single department. The aims of this study were: (1) to attempt to match the performance of two scanners, where one was preferred and (2) to assess differences between six scanners used for breast ultrasound within our organisation. The Nottingham Ultrasound Quality Assurance software was used to compare imaging performance. Images of a Gammex RMI 404GS test object were collected from six scanners, using default presets, factory presets and settings matched to a preferred scanner. Resolution, low contrast performance and high contrast performance were measured. The performance of two scanners was successfully matched, where one had been preferred. Default presets varied across the six scanners, three different presets being used. The most used preset differed in settings across the scanners, most notably in the use of different frequency modes. The factory preset was more consistent across the scanners, the main variation being in dynamic range (55-70 dB). Image comparisons showed significant differences, which were reduced or eliminated by adjustment of settings to match a reference scanner. It is possible to match scanner performance using the Nottingham Ultrasound Quality Assurance software as a verification tool. Ultrasound users should be aware that scanners may not behave in a similar fashion, even with apparently equivalent presets. It should be possible to harmonise presets by consensus amongst users.

  8. Towards plant wires

    OpenAIRE

    Adamatzky, Andrew

    2014-01-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self...

  9. Compensation strategies for PET scanners with unconventional scanner geometry

    CERN Document Server

    Gundlich, B; Oehler, M

    2006-01-01

    The small animal PET scanner ClearPET®Neuro, developed at the Forschungszentrum Julich GmbH in cooperation with the Crystal Clear Collaboration (CERN), represents scanners with an unconventional geometry: due to axial and transaxial detector gaps ClearPet®Neuro delivers inhomogeneous sinograms with missing data. When filtered backprojection (FBP) or Fourier rebinning (FORE) are applied, strong geometrical artifacts appear in the images. In this contribution we present a method that takes the geometrical sensitivity into account and converts the measured sinograms into homogeneous and complete data. By this means artifactfree images are achieved using FBP or FORE. Besides an advantageous measurement setup that reduces inhomogeneities and data gaps in the sinograms, a modification of the measured sinograms is necessary. This modification includes two steps: a geometrical normalization and corrections for missing data. To normalize the measured sinograms, computed sinograms are used that describe the geometric...

  10. Photovoltaic Wire, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  11. Photovoltaic Wire Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  12. 1998 wire development workshop proceedings

    International Nuclear Information System (INIS)

    1998-04-01

    This report consists of vugraphs of the presentations at the conference. The conference was divided into the following sessions: (1) First Generation Wire Development: Status and Issues; (2) First Generation Wire in Pre-Commercial Prototypes; (3) Second Generation Wire Development: Private Sector Progress and Issues; (4) Second Generation Wire Development: Federal Laboratories; and (5) Fundamental Research Issues for HTS Wire Development

  13. Silicon Nano wires with MoSx and Pt as Electrocatalysts for Hydrogen Evolution Reaction

    International Nuclear Information System (INIS)

    Hsieh, S.H.; Ho, S.T.; Chen, W.J.

    2016-01-01

    A convenient method was used for synthesizing Pt-nanoparticle//silicon nano wires nano composites. Obtained Pt-/silicon nano wires electrocatalysts were characterized by transmission electron microscopy (TEM). The hydrogen evolution reaction efficiency of the Pt-/silicon nano wire nano composite catalysts was assessed by examining polarization and electrolysis measurements under solar light irradiations. The electrochemical characterizations demonstrate that Pt-/silicon nano wire electrodes exhibited an excellent catalytic activity for hydrogen evolution reaction in an acidic electrolyte. The hydrogen production capability of Pt-/silicon nano wires is also comparable to /silicon nano wires and Pt/silicon nano wires. Electrochemical impedance spectroscopy experiments suggest that the enhanced performance of Pt-/silicon nano wires can be attributed to the fast electron transfer between Pt-/silicon nano wire electrodes and electrolyte interfaces.

  14. Wire Array Photovoltaics

    Science.gov (United States)

    Turner-Evans, Dan

    Over the past five years, the cost of solar panels has dropped drastically and, in concert, the number of installed modules has risen exponentially. However, solar electricity is still more than twice as expensive as electricity from a natural gas plant. Fortunately, wire array solar cells have emerged as a promising technology for further lowering the cost of solar. Si wire array solar cells are formed with a unique, low cost growth method and use 100 times less material than conventional Si cells. The wires can be embedded in a transparent, flexible polymer to create a free-standing array that can be rolled up for easy installation in a variety of form factors. Furthermore, by incorporating multijunctions into the wire morphology, higher efficiencies can be achieved while taking advantage of the unique defect relaxation pathways afforded by the 3D wire geometry. The work in this thesis shepherded Si wires from undoped arrays to flexible, functional large area devices and laid the groundwork for multijunction wire array cells. Fabrication techniques were developed to turn intrinsic Si wires into full p-n junctions and the wires were passivated with a-Si:H and a-SiNx:H. Single wire devices yielded open circuit voltages of 600 mV and efficiencies of 9%. The arrays were then embedded in a polymer and contacted with a transparent, flexible, Ni nanoparticle and Ag nanowire top contact. The contact connected >99% of the wires in parallel and yielded flexible, substrate free solar cells featuring hundreds of thousands of wires. Building on the success of the Si wire arrays, GaP was epitaxially grown on the material to create heterostructures for photoelectrochemistry. These cells were limited by low absorption in the GaP due to its indirect bandgap, and poor current collection due to a diffusion length of only 80 nm. However, GaAsP on SiGe offers a superior combination of materials, and wire architectures based on these semiconductors were investigated for multijunction

  15. Free-space wavelength-multiplexed optical scanner demonstration.

    Science.gov (United States)

    Yaqoob, Zahid; Riza, Nabeel A

    2002-09-10

    Experimental demonstration of a no-moving-parts free-space wavelength-multiplexed optical scanner (W-MOS) is presented. With fast tunable lasers or optical filters and planar wavelength dispersive elements such as diffraction gratings, this microsecond-speed scanner enables large several-centimeter apertures for subdegree angular scans. The proposed W-MOS design incorporates a unique optical amplifier and variable optical attenuator combination that enables the calibration and modulation of the scanner response, leading to any desired scanned laser beam power shaping. The experimental setup uses a tunable laser centered at 1560 nm and a 600-grooves/mm blazed reflection grating to accomplish an angular scan of 12.92 degrees as the source is tuned over an 80-nm bandwidth. The values for calculated maximum optical beam divergance, required wavelength resolution, beam-pointing accuracy, and measured scanner insertion loss are 1.076 mrad, 0.172 nm, 0.06 mrad, and 4.88 dB, respectively.

  16. Vacuum Attachment for XRF Scanner

    Science.gov (United States)

    Schramm, Harry F.; Kaiser, Bruce

    2005-01-01

    Vacuum apparatuses have been developed for increasing the range of elements that can be identified by use of x-ray fluorescent (XRF) scanners of the type mentioned in the two immediately preceding articles. As a consequence of the underlying physical principles, in the presence of air, such an XRF scanner is limited to analysis of chlorine and elements of greater atomic number. When the XRF scanner is operated in a vacuum, it extends the range of analysis to lower atomic numbers - even as far as aluminum and sodium. Hence, more elements will be available for use in XRF labeling of objects as discussed in the two preceding articles. The added benefits of the extended capabilities also have other uses for NASA. Detection of elements of low atomic number is of high interest to the aerospace community. High-strength aluminum alloys will be easily analyzed for composition. Silicon, a major contaminant in certain processes, will be detectable before the process is begun, possibly eliminating weld or adhesion problems. Exotic alloys will be evaluated for composition prior to being placed in service where lives depend on them. And in the less glamorous applications, such as bolts and fasteners, substandard products and counterfeit items will be evaluated at the receiving function and never allowed to enter the operation

  17. Automating wiring formboard design

    NARCIS (Netherlands)

    Van den Berg, T.

    2013-01-01

    Increase in aircraft wiring complexity call for manufacturing design improvements to reduce cost and lead-time. To achieve such improvements, a joint research project was performed by the Flight Performance and Propulsion (FPP) group and Fokker Elmo BV, the second largest aircraft wiring harness

  18. NMR of geophysical drill cores with a mobile Halbach scanner

    International Nuclear Information System (INIS)

    Talnishnikh, E.

    2007-01-01

    This thesis is devoted to a mobile NMR with an improved Halbach scanner. This is a lightweight tube-shaped magnet with sensitive volume larger and a homogeneity of the magnetic field higher than the previous prototype version. The improved Halbach scanner is used for analysis of water-saturated drill cores and plugs with diameters up to 60 mm. To provide the analysis, the standard 1D technique with the CPMG sequence as well as 2D correlation experiments were successfully applied and adapted to study properties of fluid-saturated sediments. Afterwards the Halbach scanner was calibrated to fast non-destructive measurements of porosity, relaxation time distributions, and estimation of permeability. These properties can be calculated directly from the NMR data using the developed methodology. Any independent measurements of these properties with other methods are not needed. One of the main results of this work is the development of a new NMR on-line core scanner for measurements of porosity in long cylindrical and semi cylindrical drill cores. Also dedicated software was written to operate the NMR on-line core scanner. The physical background of this work is the study of the diffusion influence on transverse relaxation. The diffusion effect in the presence of internal gradients in porous media was probed by 1D and 2D experiments. The transverse relaxation time distributions obtained from 1D and from 2D experiments are comparable but different in fine details. Two new methodologies were developed based on the results of this study. First is the methodology quantifying the influence of diffusion in the internal gradients of water-saturated sediments on transverse relaxation from 2D correlation experiments. The second one is the correction of the permeability estimation from the NMR data taking in account the influence of the diffusion. Furthermore, PFG NMR technique was used to study restricted diffusion in the same kind of samples. Preliminary results are reported

  19. NMR of geophysical drill cores with a mobile Halbach scanner

    Energy Technology Data Exchange (ETDEWEB)

    Talnishnikh, E.

    2007-08-21

    This thesis is devoted to a mobile NMR with an improved Halbach scanner. This is a lightweight tube-shaped magnet with sensitive volume larger and a homogeneity of the magnetic field higher than the previous prototype version. The improved Halbach scanner is used for analysis of water-saturated drill cores and plugs with diameters up to 60 mm. To provide the analysis, the standard 1D technique with the CPMG sequence as well as 2D correlation experiments were successfully applied and adapted to study properties of fluid-saturated sediments. Afterwards the Halbach scanner was calibrated to fast non-destructive measurements of porosity, relaxation time distributions, and estimation of permeability. These properties can be calculated directly from the NMR data using the developed methodology. Any independent measurements of these properties with other methods are not needed. One of the main results of this work is the development of a new NMR on-line core scanner for measurements of porosity in long cylindrical and semi cylindrical drill cores. Also dedicated software was written to operate the NMR on-line core scanner. The physical background of this work is the study of the diffusion influence on transverse relaxation. The diffusion effect in the presence of internal gradients in porous media was probed by 1D and 2D experiments. The transverse relaxation time distributions obtained from 1D and from 2D experiments are comparable but different in fine details. Two new methodologies were developed based on the results of this study. First is the methodology quantifying the influence of diffusion in the internal gradients of water-saturated sediments on transverse relaxation from 2D correlation experiments. The second one is the correction of the permeability estimation from the NMR data taking in account the influence of the diffusion. Furthermore, PFG NMR technique was used to study restricted diffusion in the same kind of samples. Preliminary results are reported

  20. A micron resolution optical scanner for characterization of silicon detectors

    International Nuclear Information System (INIS)

    Shukla, R. A.; Dugad, S. R.; Gopal, A. V.; Gupta, S. K.; Prabhu, S. S.; Garde, C. S.

    2014-01-01

    The emergence of high position resolution (∼10 μm) silicon detectors in recent times have highlighted the urgent need for the development of new automated optical scanners of micron level resolution suited for characterizing microscopic features of these detectors. More specifically, for the newly developed silicon photo-multipliers (SiPM) that are compact, possessing excellent photon detection efficiency with gain comparable to photo-multiplier tube. In a short time, since their invention the SiPMs are already being widely used in several high-energy physics and astrophysics experiments as the photon readout element. The SiPM is a high quantum efficiency, multi-pixel photon counting detector with fast timing and high gain. The presence of a wide variety of photo sensitive silicon detectors with high spatial resolution requires their performance evaluation to be carried out by photon beams of very compact spot size. We have designed a high resolution optical scanner that provides a monochromatic focused beam on a target plane. The transverse size of the beam was measured by the knife-edge method to be 1.7 μm at 1 − σ level. Since the beam size was an order of magnitude smaller than the typical feature size of silicon detectors, this optical scanner can be used for selective excitation of these detectors. The design and operational details of the optical scanner, high precision programmed movement of target plane (0.1 μm) integrated with general purpose data acquisition system developed for recording static and transient response photo sensitive silicon detector are reported in this paper. Entire functionality of scanner is validated by using it for selective excitation of individual pixels in a SiPM and identifying response of active and dead regions within SiPM. Results from these studies are presented in this paper

  1. Thermosonic wire bonding of IC devices using palladium wire

    International Nuclear Information System (INIS)

    Shze, J.H.; Poh, M.T.; Tan, R.M.

    1996-01-01

    The feasibility of replacing gold wire by palladium wire in thermosonic wire bonding of CMOS and bipolar devices are studied in terms of the manufacturability, physical, electrical and assembly performance. The results that palladium wire is a viable option for bonding the bipolar devices but not the CMOS devices

  2. Towards plant wires.

    Science.gov (United States)

    Adamatzky, Andrew

    2014-08-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self-growing wetware circuits and devices, and integration of plant-based electronic components into future and emergent bio-hybrid systems. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. The wire array Z pinch programme at Imperial College

    International Nuclear Information System (INIS)

    Haines, M.G.; Lebedev, S.V.; Chittenden, J.P.; Bland, S.N.; Beg, F.N.; Dangor, A.E.; Pikuz, S.A.; Shelkovenko, T.A.

    2001-01-01

    Plasma formation and implosion dynamics of wire array z-pinches have been studied experimentally using the MAGPIE generator (1.4MA, 240ns) at Imperial College. Simulations and theory verify much of the data. Both laser probing and x-ray radiography show after an initial volumetric heating of the wires the presence of dense wire cores surrounded by low density coronal plasma. Radiography shows development of perturbations on the dense core of each wire, while laser probing shows inward jetting of the coronal plasma caused by the global JxB force, and these plasma streams are axially non-uniform on the same spatial scale as later seen in the wire cores. The spatial scale of these perturbations (∼0.5mm for Al, ∼0.25mm for W) increases with the size of the wire cores (∼0.25mm for Al, ∼0.1mm for W). The inward flow of the coronal plasma is usually field free and leads to formation on the array axis of a straight plasma column, the dynamics of which is strongly affected by radiation cooling. Images obtained by optical streak camera show that the wire cores start their inward motion late and the implosion trajectory deviates significantly from the expected from 0-D analysis. An increase of the number of wires (decrease of inter-wire gap) resulted in a transition to 0-D trajectory for aluminium wire arrays, but not for tungsten. In experiments with nested wire arrays two modes of behaviour are observed; in the first the inner array is transparent to the imploding outer array, but the current transfers to it, leading to a fast implosion. The second mode occurs when a significant fraction of current is flowing in the inner array and the two arrays apparently implode simultaneously. In both modes the x-ray pulse is significantly sharpened in comparison with that generated in implosion of a single wire array. (author)

  4. Self-organization of mesoscopic silver wires by electrochemical deposition

    Directory of Open Access Journals (Sweden)

    Sheng Zhong

    2014-08-01

    Full Text Available Long, straight mesoscale silver wires have been fabricated from AgNO3 electrolyte via electrodeposition without the help of templates, additives, and surfactants. Although the wire growth speed is very fast due to growth under non-equilibrium conditions, the wire morphology is regular and uniform in diameter. Structural studies reveal that the wires are single-crystalline, with the [112] direction as the growth direction. A possible growth mechanism is suggested. Auger depth profile measurements show that the wires are stable against oxidation under ambient conditions. This unique system provides a convenient way for the study of self-organization in electrochemical environments as well as for the fabrication of highly-ordered, single-crystalline metal nanowires.

  5. Cryogenic Pressure Seal for Wires

    Science.gov (United States)

    Ciana, J. J.

    1984-01-01

    High-pressure-seal formed by forcing polyurethane into space surrounding wire or cable in special fitting. Wire or cable routed through fitting then through a tightly fitting cap. Wire insulation left intact. Cap filled with sealant and forced onto the fitting: this pushes sealant into fitting so it seals wire or cable in fitting as well as in cap.

  6. Gamma scanner conceptual design report

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1979-11-01

    The Fuels and Materials Examination Facility (FMEF) will include several stations for the nondestructive examination of irradiated fuels. One of these stations will be the gamma scanner which will be employed to detect gamma radiation from the irradiated fuel pins. The conceptual design of the gamma scan station is described. The gamma scanner will use a Standard Exam Stage (SES) as a positioner and transport mechanism for the fuel pins which it will obtain from a magazine. A pin guide mechanism mounted on the face of the collimator will assure that the fuel pins remain in front of the collimator during scanning. The collimator has remotely adjustable tungsten slits and can be manually rotated to align the slit at various angles. A shielded detector cart located in the operating corridor holds an intrinsic germanium detector and associated sodium-iodide anticoincidence detector. The electronics associated with the counting system consist of standard NIM modules to process the detector signals and a stand-alone multichannel analyzer (MCA) for counting data accumulation. Data from the MCA are bussed to the station computer for analysis and storage on magnetic tape. The station computer controls the collimator, the MCA, a source positioner and the SES through CAMAC-based interface hardware. Most of the electronic hardware is commercially available but some interfaces will require development. Conceptual drawings are included for mechanical hardware that must be designed and fabricated

  7. Experience with a fuel rod enrichment scanner

    International Nuclear Information System (INIS)

    Kubik, R.N.; Pettus, W.G.

    1975-01-01

    This enrichment scanner views all fuel rods produced at B and W's Commercial Nuclear Fuel Plant. The scanner design is derived from the PAPAS System reported by R. A. Forster, H. D. Menlove, and their associates at Los Alamos. The spatial resolution of the system and smoothing of the data are discussed in detail. The cost-effectiveness of multi-detector versus single detector scanners of this general design is also discussed

  8. Copper wire bonding

    CERN Document Server

    Chauhan, Preeti S; Zhong, ZhaoWei; Pecht, Michael G

    2014-01-01

    This critical volume provides an in-depth presentation of copper wire bonding technologies, processes and equipment, along with the economic benefits and risks.  Due to the increasing cost of materials used to make electronic components, the electronics industry has been rapidly moving from high cost gold to significantly lower cost copper as a wire bonding material.  However, copper wire bonding has several process and reliability concerns due to its material properties.  Copper Wire Bonding book lays out the challenges involved in replacing gold with copper as a wire bond material, and includes the bonding process changes—bond force, electric flame off, current and ultrasonic energy optimization, and bonding tools and equipment changes for first and second bond formation.  In addition, the bond–pad metallurgies and the use of bare and palladium-coated copper wires on aluminum are presented, and gold, nickel and palladium surface finishes are discussed.  The book also discusses best practices and re...

  9. Robotic Prostate Biopsy in Closed MRI Scanner

    National Research Council Canada - National Science Library

    Fischer, Gregory

    2008-01-01

    .... This work enables prostate brachytherapy and biopsy procedures in standard high-field diagnostic MRI scanners through the development of a robotic needle placement device specifically designed...

  10. Gamma spectrometry on MANITU 271-01 gamma scan wires

    International Nuclear Information System (INIS)

    Dassel, G.; Buurveld, H.A.; Minkema, J.

    1994-08-01

    A series of irradiation experiments (271-series) is being performed of the sustain programme for material development and characterization of the NET (Next European Torus). In the framework of the first irradiation experiment 271-01, with irradiation up to 0.2 dpa, four gamma scan wires have been examined by gamma scanning. The purpose of the gamma scan wires (GSW) is to get information about the neutron fluence distribution in the capsules during irradiation. In the stainless steel wires the nuclides Co-58, Mu-54, Fe-59 and Co-60 are produced, are characteristic for fast and thermal neutron reactions. (orig./HP)

  11. Laser Scanner For Automatic Storage

    Science.gov (United States)

    Carvalho, Fernando D.; Correia, Bento A.; Rebordao, Jose M.; Rodrigues, F. Carvalho

    1989-01-01

    The automated magazines are beeing used at industry more and more. One of the problems related with the automation of a Store House is the identification of the products envolved. Already used for stock management, the Bar Codes allows an easy way to identify one product. Applied to automated magazines, the bar codes allows a great variety of items in a small code. In order to be used by the national producers of automated magazines, a devoted laser scanner has been develloped. The Prototype uses an He-Ne laser whose beam scans a field angle of 75 degrees at 16 Hz. The scene reflectivity is transduced by a photodiode into an electrical signal, which is then binarized. This digital signal is the input of the decodifying program. The machine is able to see barcodes and to decode the information. A parallel interface allows the comunication with the central unit, which is responsible for the management of automated magazine.

  12. 3D whole body scanners revisited

    NARCIS (Netherlands)

    Daanen, H.A.M.; Haar, F.B. ter

    2013-01-01

    An overview of whole body scanners in 1998 (H.A.M. Daanen, G.J. Van De Water. Whole body scanners, Displays 19 (1998) 111-120) shortly after they emerged to the market revealed that the systems were bulky, slow, expensive and low in resolution. This update shows that new developments in sensing and

  13. Comparative Analysis of Computer Network Security Scanners

    Directory of Open Access Journals (Sweden)

    Victor Sergeevich Gorbatov

    2013-02-01

    Full Text Available The paper is devoted to the analysis of the problem of comparison of security scanners computer network. A common comprehensive assessment of security control is developed on the base of comparative analysis of data security controls. We have tested security scanners available on the market.

  14. Scanner for ultrasonic scanning of surfaces.

    NARCIS (Netherlands)

    Berkhout, A.J.; Van Hoorn, W.A.

    1991-01-01

    Abstract of EP 0453014 (A1) Scanner for scanning surfaces with ultrasonic signals, in particular surfaces of parts of the body, provided with a scanner head (5) for the transmission of ultrasonic signals and the reception of the echoes hereof. The time passed between the emission of the signal and

  15. Wired to freedom

    DEFF Research Database (Denmark)

    Jepsen, Kim Sune Karrasch; Bertilsson, Margareta

    2017-01-01

    dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being “wired to freedom” that involves...... new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as “wired to freedom,” we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear...

  16. Wiring and lighting

    CERN Document Server

    Kitcher, Chris

    2013-01-01

    Wiring and Lighting provides a comprehensive guide to DIY wiring around the home. It sets out the regulations and legal requirements surrounding electrical installation work, giving clear guidelines that will enable the reader to understand what electrical work they are able to carry out, and what the testing and certification requirements are once the work is completed. Topics covered include: Different types of circuits; Types of cables and cable installation under floors and through joists; Isolating, earthing and bonding; Accessory boxes and fixings; Voltage bands; Detailed advice on safe

  17. Electric wiring domestic

    CERN Document Server

    Coker, A J

    1992-01-01

    Electric Wiring: Domestic, Tenth Edition, is a clear and reliable guide to the practical aspects of domestic electric wiring. Intended for electrical contractors, installation engineers, wiremen and students, its aim is to provide essential up to date information on modern methods and materials in a simple, clear, and concise manner. The main changes in this edition are those necessary to bring the work into line with the 16th Edition of the Regulations for Electrical Installations issued by the Institution of Electrical Engineers. The book begins by introducing the basic features of domestic

  18. Modern wiring practice

    CERN Document Server

    Steward, W E

    2012-01-01

    Continuously in print since 1952, Modern Wiring Practice has now been fully revised to provide an up-to-date source of reference to building services design and installation in the 21st century. This compact and practical guide addresses wiring systems design and electrical installation together in one volume, creating a comprehensive overview of the whole process for contractors and architects, as well as electricians and other installation engineers. Best practice is incorporated throughout, combining theory and practice with clear and accessible explanation, all

  19. Clinical applications of a high quantum utilization scanner. Final report

    International Nuclear Information System (INIS)

    Crandall, P.H.; Cassen, B.

    1973-04-01

    The clinical usefulness of a tomographic imaging process employing a fast rectilinear scanner consisted of a spherical-cap nest of seven individual detectors (3'' x 1 / 2 '' activated sodium iodide) collimated to a common focal point at 10 cm. Hydraulic drives permitted a fast rectilinear scan to be made and, when raised or lowered, at different planes. Patients with well-defined brain lesions were studied using /sup 99m/Tc-pertechnetate or 203 Hg-chlormerodrin as tracers by measuring three dimensions of their lesions and anatomical location at the time of operation. Brain maps were used to identify this location at operation and also the location of images traced from film density displays of a conventional radioisotopic scan, the tomographic scan, and cerebral angiograms. (U.S.)

  20. A PDMS-Based 2-Axis Waterproof Scanner for Photoacoustic Microscopy

    Directory of Open Access Journals (Sweden)

    Jin Young Kim

    2015-04-01

    Full Text Available Optical-resolution photoacoustic microscopy (OR-PAM is an imaging tool to provide in vivo optically sensitive images in biomedical research. To achieve a small size, fast imaging speed, wide scan range, and high signal-to-noise ratios (SNRs in a water environment, we introduce a polydimethylsiloxane (PDMS-based 2-axis scanner for a flexible and waterproof structure. The design, theoretical background, fabrication process and performance of the scanner are explained in details. The designed and fabricated scanner has dimensions of 15 × 15 × 15 mm along the X, Y and Z axes, respectively. The characteristics of the scanner are tested under DC and AC conditions. By pairing with electromagnetic forces, the maximum scanning angles in air and water are 18° and 13° along the X and Y axes, respectively. The measured resonance frequencies in air and water are 60 and 45 Hz along the X axis and 45 and 30 Hz along the Y axis, respectively. Finally, OR-PAM with high SNRs is demonstrated using the fabricated scanner, and the PA images of micro-patterned samples and microvasculatures of a mouse ear are successfully obtained with high-resolution and wide-field of view. OR-PAM equipped with the 2-axis PDMS based waterproof scanner has lateral and axial resolutions of 3.6 μm and 26 μm, respectively. This compact OR-PAM system could potentially and widely be used in preclinical and clinical applications.

  1. Three-dimensional rectilinear scanner

    International Nuclear Information System (INIS)

    O'Neill, W.J.; Strange, D.R.; Miller, A.

    1976-01-01

    A rectilinear scanner for detecting radiation in a plurality of channels utilizing a collimator is described. Each of the channels receives information from a different portion of the collimator. Information separately received is separately messaged and later collated to present a common image. The information is processed by apparatus in a data processing system. This system has means for messaging analog signals corresponding to gamma radiation counts and converting such analog signals to digital signals. This system has means interfacing the digital signals into an address register that communicates directly via data busses to core memory of a central processing unit by cycle stealing and deriving clinically significant information by computation on the resultant digital data. This system has means for storing, retrieving, and displaying the resultant digital data and the resultant derivations therefrom collectively. This is done in such a manner as to allow time sequencing of the aforementioned operations such that the aforementioned operations can be interleaved on a real time basis. 13 claims, 44 figures

  2. Practical wiring in SI units

    CERN Document Server

    Miller, Henry A

    2013-01-01

    Practical Wiring, Volume 1 is a 13-chapter book that first describes some of the common hand tools used in connection with sheathed wiring. Subsequent chapters discuss the safety in wiring, cables, conductor terminations, insulating sheathed wiring, conductor sizes, and consumer's control equipments. Other chapters center on socket outlets, plugs, lighting subcircuits, lighting accessories, bells, and primary and secondary cells. This book will be very valuable to students involved in this field of interest.

  3. Wire EDM for Refractory Materials

    Science.gov (United States)

    Zellars, G. R.; Harris, F. E.; Lowell, C. E.; Pollman, W. M.; Rys, V. J.; Wills, R. J.

    1982-01-01

    In an attempt to reduce fabrication time and costs, Wire Electrical Discharge Machine (Wire EDM) method was investigated as tool for fabricating matched blade roots and disk slots. Eight high-strength nickel-base superalloys were used. Computer-controlled Wire EDM technique provided high quality surfaces with excellent dimensional tolerances. Wire EDM method offers potential for substantial reductions in fabrication costs for "hard to machine" alloys and electrically conductive materials in specific high-precision applications.

  4. Wire chambers: Trends and alternatives

    International Nuclear Information System (INIS)

    Regler, Meinhard

    1992-01-01

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!

  5. Command Wire Sensor Measurements

    Science.gov (United States)

    2012-09-01

    CFAR Constant False Alarm Rate CWIE Command Wire-Improvised Explosive Device EMI Electromagnetic Induction GPR Ground Penetrating Radar...this, some type of constant false alarm rate ( CFAR ) receiver is required. CFAR automatically raises the threshold level to keep clutter echoes and

  6. Transport in quantum wires

    Indian Academy of Sciences (India)

    Transport in quantum wires. SIDDHARTHA LAL, SUMATHI RAO£ and DIPTIMAN SEN. Centre for Theoretical Studies, Indian Institute of Science, Bangalore 560 012, India. £ Harish-chandra Research Institute, Chhatnag Road, Jhusi, Allahabad 211 019, India. Abstract. With a brief introduction to one-dimensional channels ...

  7. Wire chamber conference

    International Nuclear Information System (INIS)

    Bartl, W.; Neuhofer, G.; Regler, M.

    1986-02-01

    This booklet contains program and the abstracts of the papers presented at the conference, most of them dealing with performance testing of various types of wire chambers. The publication of proceedings is planned as a special issue of 'Nuclear instruments and methods' later on. All abstracts are in English. An author index for the book of abstracts is given. (A.N.)

  8. The effect of electrostatic and gravity force on offset wire inside tube

    Science.gov (United States)

    Oh, S. H.; Hazineh, D.; Wang, C.

    2018-04-01

    In a straw-tube detector, a wire that is offset with respect to the tube axis experiences a Coulomb force when high voltage is applied between the anode wire and the tube. This force results in a shifting of the wire and straw, in addition to the gravitational sag, and is a function of the tube and wire radius, initial offset, high voltage, tension and length. The presence of such effects is well known, but the precise magnitude of the shift for the anode wires under conditions of detector operation have not been previously documented with measurable confidence. In this work, we provide the first systematic measurements for the wire shift in straw-tube detectors due to gravity and the electrostatic force using an x-ray scanner developed for the Mu2e experiment. The data are compared to the solutions of the differential equations governing the system, and we find a good match between the two. The solutions can predict the final wire and straw positions from the initial positions measured without the high voltage, and the final wire and straw positions can then be used as an input to the track reconstruction software to improve the track position resolution.

  9. WindScanner.eu - a new Remote Sensing Research Infrastructure for On- and Offshore Wind Energy

    DEFF Research Database (Denmark)

    Mikkelsen, Torben; Siggaard Knudsen, Søren; Sjöholm, Mikael

    2012-01-01

    will be disseminated throughout Europe to pilot European wind energy research centers. The new research infrastructure will become an open source infrastructure that also invites collaboration with wind energy related atmospheric scientists and wind energy industry overseas. Recent achievements with 3D Wind......Scanners and spin-off innovation activity are described. The Danish WindScanner.dk research facility is build from new and fast-scanning remote sensing equipment spurred from achievements within fiber optics and telecommunication technologies. At the same time the wind energy society has demanded excessive 3D wind...

  10. A Cross-Platform Smartphone Brain Scanner

    DEFF Research Database (Denmark)

    Larsen, Jakob Eg; Stopczynski, Arkadiusz; Stahlhut, Carsten

    We describe a smartphone brain scanner with a low-costwireless 14-channel Emotiv EEG neuroheadset interfacingwith multiple mobile devices. This personal informaticssystem enables minimally invasive and continuouscapturing of brain imaging data in natural settings. Thesystem applies an inverse...

  11. Enhanced methodology of focus control and monitoring on scanner tool

    Science.gov (United States)

    Chen, Yen-Jen; Kim, Young Ki; Hao, Xueli; Gomez, Juan-Manuel; Tian, Ye; Kamalizadeh, Ferhad; Hanson, Justin K.

    2017-03-01

    As the demand of the technology node shrinks from 14nm to 7nm, the reliability of tool monitoring techniques in advanced semiconductor fabs to achieve high yield and quality becomes more critical. Tool health monitoring methods involve periodic sampling of moderately processed test wafers to detect for particles, defects, and tool stability in order to ensure proper tool health. For lithography TWINSCAN scanner tools, the requirements for overlay stability and focus control are very strict. Current scanner tool health monitoring methods include running BaseLiner to ensure proper tool stability on a periodic basis. The focus measurement on YIELDSTAR by real-time or library-based reconstruction of critical dimensions (CD) and side wall angle (SWA) has been demonstrated as an accurate metrology input to the control loop. The high accuracy and repeatability of the YIELDSTAR focus measurement provides a common reference of scanner setup and user process. In order to further improve the metrology and matching performance, Diffraction Based Focus (DBF) metrology enabling accurate, fast, and non-destructive focus acquisition, has been successfully utilized for focus monitoring/control of TWINSCAN NXT immersion scanners. The optimal DBF target was determined to have minimized dose crosstalk, dynamic precision, set-get residual, and lens aberration sensitivity. By exploiting this new measurement target design, 80% improvement in tool-to-tool matching, >16% improvement in run-to-run mean focus stability, and >32% improvement in focus uniformity have been demonstrated compared to the previous BaseLiner methodology. Matching <2.4 nm across multiple NXT immersion scanners has been achieved with the new methodology of set baseline reference. This baseline technique, with either conventional BaseLiner low numerical aperture (NA=1.20) mode or advanced illumination high NA mode (NA=1.35), has also been evaluated to have consistent performance. This enhanced methodology of focus

  12. Distribution of Energy Deposited in Plastic Tubing and Copper-Wire Insulation by Electron Beam Irradiation

    DEFF Research Database (Denmark)

    Pedersen, Walther Batsberg; Miller, Arne; Pejtersen, K.

    1978-01-01

    Scanned electron beam treatment is used to improve the physical properties of certain polymers, such as shrinkable plastic tubing and insulated wire and cable. Tubing or wires are passed at high speed under the beam scanner, and the material is irradiated to absorbed doses of several Mrad...... as uniformly as possible, usually by means of a multipass arrangement. In the present study, using irradiation by a scanned 0.4 MeV electron beam, measurements were made of high-resolution distributions of absorbed dose in polyethylene tubing and copper wire coated with polyethylene, nylon, or polyvinyl...... chloride insulation. Radiochromic dye films equivalent to the insulating materials were used as accurate dosimeters having a response independent of dose rate. Irradiations were in various geometries, wire and plastic thicknesses, positions along the beam scan, and with different backing materials near...

  13. Non-linear Imaging using an Experimental Synthetic Aperture Real Time Ultrasound Scanner

    DEFF Research Database (Denmark)

    Rasmussen, Joachim; Du, Yigang; Jensen, Jørgen Arendt

    2011-01-01

    This paper presents the first non-linear B-mode image of a wire phantom using pulse inversion attained via an experimental synthetic aperture real-time ultrasound scanner (SARUS). The purpose of this study is to implement and validate non-linear imaging on SARUS for the further development of new...... non-linear techniques. This study presents non-linear and linear B-mode images attained via SARUS and an existing ultrasound system as well as a Field II simulation. The non-linear image shows an improved spatial resolution and lower full width half max and -20 dB resolution values compared to linear...

  14. Dental Arch Wire

    Science.gov (United States)

    1979-01-01

    Straightening teeth is an arduous process requiring months, often years, of applying corrective pressure by means of arch wires-better known as brace-which may have to be changed several times in the course of treatment. A new method has been developed by Dr. George Andreasen, orthodontist and dental scientist at the University of Iowa. The key is a new type of arch wire material, called Nitinol, with exceptional elasticity which helps reduce the required number of brace changes. An alloy of nickel and titanium, Nitinol was originally developed for aerospace applications by the Naval Ordnance Laboratory, now the Naval Surface Weapons Laboratory, White Oaks, Maryland. NASA subsequently conducted additional research on the properties of Nitinol and on procedures for processing the metal.

  15. Wire chamber gases

    International Nuclear Information System (INIS)

    Va'vra, J.

    1992-04-01

    In this paper, we describe new developments in gas mixtures which have occurred during the last 3--4 years. In particular, we discuss new results on the measurement and modeling of electron drift parameters, the modeling of drift chamber resolution, measurements of primary ionization and the choice of gas for applications such as tracking, single electron detection, X-ray detection and visual imaging. In addition, new results are presented on photon feedback, breakdown and wire aging

  16. Vienna Wire Chamber Conference

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    After those of 1978 and 1980, a third Wire Chamber Conference was held from 15-18 February in the Technical University of Vienna. Eight invited speakers covered the field from sophisticated applications in biology and medicine, via software, to the state of the art of gaseous detectors. In some forty other talks the speakers tackled in more detail the topics of gaseous detectors, calorimetry and associated electronics and software

  17. Implementation of Order-wire Functionality in IRITEL NG-SDH devices

    Directory of Open Access Journals (Sweden)

    D. Katanić

    2011-06-01

    Full Text Available This paper describes the implementation of order-wire functionality in NG-SDH devices ODS2G5 and OTS622 IRITEL. The paper also describes the operation of order-wire in networks with arbitrary topologies, as well as the configuration of order-wire functionality by using network management software SUNCE. The presented solution for order-wire functionality is compared with VoIP solutions. The paper shows that the presented solution provides fast reaction to network failures, while keeping the implementation simple.

  18. Dual wire welding torch and method

    Science.gov (United States)

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  19. MEMS temperature scanner: principles, advances, and applications

    Science.gov (United States)

    Otto, Thomas; Saupe, Ray; Stock, Volker; Gessner, Thomas

    2010-02-01

    Contactless measurement of temperatures has gained enormous significance in many application fields, ranging from climate protection over quality control to object recognition in public places or military objects. Thereby measurement of linear or spatially temperature distribution is often necessary. For this purposes mostly thermographic cameras or motor driven temperature scanners are used today. Both are relatively expensive and the motor drive devices are limited regarding to the scanning rate additionally. An economic alternative are temperature scanner devices based on micro mirrors. The micro mirror, attached in a simple optical setup, reflects the emitted radiation from the observed heat onto an adapted detector. A line scan of the target object is obtained by periodic deflection of the micro scanner. Planar temperature distribution will be achieved by perpendicularly moving the target object or the scanner device. Using Planck radiation law the temperature of the object is calculated. The device can be adapted to different temperature ranges and resolution by using different detectors - cooled or uncooled - and parameterized scanner parameters. With the basic configuration 40 spatially distributed measuring points can be determined with temperatures in a range from 350°C - 1000°C. The achieved miniaturization of such scanners permits the employment in complex plants with high building density or in direct proximity to the measuring point. The price advantage enables a lot of applications, especially new application in the low-price market segment This paper shows principle, setup and application of a temperature measurement system based on micro scanners working in the near infrared range. Packaging issues and measurement results will be discussed as well.

  20. Assessment of the impact of the scanner-related factors on brain morphometry analysis with Brainvisa

    Directory of Open Access Journals (Sweden)

    Shokouhi Mahsa

    2011-12-01

    Full Text Available Abstract Background Brain morphometry is extensively used in cross-sectional studies. However, the difference in the estimated values of the morphometric measures between patients and healthy subjects may be small and hence overshadowed by the scanner-related variability, especially with multicentre and longitudinal studies. It is important therefore to investigate the variability and reliability of morphometric measurements between different scanners and different sessions of the same scanner. Methods We assessed the variability and reliability for the grey matter, white matter, cerebrospinal fluid and cerebral hemisphere volumes as well as the global sulcal index, sulcal surface and mean geodesic depth using Brainvisa. We used datasets obtained across multiple MR scanners at 1.5 T and 3 T from the same groups of 13 and 11 healthy volunteers, respectively. For each morphometric measure, we conducted ANOVA analysis and verified whether the estimated values were significantly different across different scanners or different sessions of the same scanner. The between-centre and between-visit reliabilities were estimated from their contribution to the total variance, using a random-effects ANOVA model. To estimate the main processes responsible for low reliability, the results of brain segmentation were compared to those obtained using FAST within FSL. Results In a considerable number of cases, the main effects of both centre and visit factors were found to be significant. Moreover, both between-centre and between-visit reliabilities ranged from poor to excellent for most morphometric measures. A comparison between segmentation using Brainvisa and FAST revealed that FAST improved the reliabilities for most cases, suggesting that morphometry could benefit from improving the bias correction. However, the results were still significantly different across different scanners or different visits. Conclusions Our results confirm that for morphometry

  1. Metering Wheel-Wire Track Wire Boom Deployment Mechanism

    Science.gov (United States)

    Granoff, Mark S.

    2014-01-01

    The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.

  2. Cognition for robot scanner based remote welding

    Science.gov (United States)

    Thombansen, U.; Ungers, Michael

    2014-02-01

    The effort for reduced cycle times in manufacturing has supported the development of remote welding systems which use a combination of scanners for beam delivery and robots for scanner positioning. Herein, close coupling of both motions requires a precise command of the robot trajectory and the scanner positioning to end up with a combined beam delivery. Especially the path precision of the robot plays a vital role in this kinematic chain. In this paper, a sensor system is being presented which allows tracking the motion of the laser beam against the work piece. It is based on a camera system which is coaxially connected to the scanner thus observing the relative motion of the laser beam relative to the work piece. The acquired images are processed with computer vision algorithms from the field of motion detection. The suitability of the algorithms is being demonstrated with a motion tracking tool which visualizes the homogeneity of the tracking result. The reported solution adds cognitive capabilities to manufacturing systems for robot scanner based materials processing. It allows evaluation of the relative motion between work piece and the laser beam. Moreover, the system can be used to adapt system programming during set-up of a manufacturing task or to evaluate the functionality of a manufacturing system during production. The presented sensor system will assist in optimizing manufacturing processes.

  3. A flexible and wearable terahertz scanner

    Science.gov (United States)

    Suzuki, D.; Oda, S.; Kawano, Y.

    2016-12-01

    Imaging technologies based on terahertz (THz) waves have great potential for use in powerful non-invasive inspection methods. However, most real objects have various three-dimensional curvatures and existing THz technologies often encounter difficulties in imaging such configurations, which limits the useful range of THz imaging applications. Here, we report the development of a flexible and wearable THz scanner based on carbon nanotubes. We achieved room-temperature THz detection over a broad frequency band ranging from 0.14 to 39 THz and developed a portable THz scanner. Using this scanner, we performed THz imaging of samples concealed behind opaque objects, breakages and metal impurities of a bent film and multi-view scans of a syringe. We demonstrated a passive biometric THz scan of a human hand. Our results are expected to have considerable implications for non-destructive and non-contact inspections, such as medical examinations for the continuous monitoring of health conditions.

  4. Quality assurance of computed tomography (CT) scanners

    International Nuclear Information System (INIS)

    Sankaran, A.; Sanu, K.K. . Email : a_sankaran@vsnl.com

    2004-01-01

    This article reviews the present status of research work and development of various test objects, phantoms and detector/instrumentation systems for quality assurance (QA) of computed tomography (CT) scanners, carried out in advanced countries, with emphasis on similar work done in this research centre. CT scanner is a complex equipment and routine quality control procedures are essential to the maintenance of image quality with optimum patient dose. Image quality can be ensured only through correlation between prospective monitoring of system components and tests of overall performance with standard phantoms. CT examinations contribute a large share to the population dose in advanced countries. The unique dosimetry problems in CT necessitate special techniques. This article describes a comprehensive kit developed indigenously for the following QA and type approval tests as well as for research studies on image quality/dosimetry on CT scanners

  5. Manually operated small envelope scanner system

    Energy Technology Data Exchange (ETDEWEB)

    Sword, Charles Keith

    2017-04-18

    A scanner system and method for acquisition of position-based ultrasonic inspection data are described. The scanner system includes an inspection probe and a first non-contact linear encoder having a first sensor and a first scale to track inspection probe position. The first sensor is positioned to maintain a continuous non-contact interface between the first sensor and the first scale and to maintain a continuous alignment of the first sensor with the inspection probe. The scanner system may be used to acquire two-dimensional inspection probe position data by including a second non-contact linear encoder having a second sensor and a second scale, the second sensor positioned to maintain a continuous non-contact interface between the second sensor and the second scale and to maintain a continuous alignment of the second sensor with the first sensor.

  6. Wire communication engineering

    International Nuclear Information System (INIS)

    Son, Byeong Tae

    1997-02-01

    This book describes wire telecommunication engineering/ It is divided into eleven chapter, which deal with Introduction with development of telecommunication, voice and sound wave and communication network, Telegraphy with summary of telegraphy, code of telegraphy, communication speed, morse and telex, Telephone on structure, circuit and image telephone, Traffic on telecommunication traffic, transmission of line about theory, cable line and loaded cable, carrier communication with carrier telegraphy and carrier telephone, optical communication with types, structure, specialty, laser and equipment, DATA, Mobile telecommunication on summary, mobile telephone, radio paging and digital mobile telecommunication, ISDN with channel of ISDN, and service of ISDN, and design of telecommunication.

  7. Wiring regulations in brief

    CERN Document Server

    Tricker, Ray

    2012-01-01

    Tired of trawling through the Wiring Regs?Perplexed by Part P?Confused by cables, conductors and circuits?Then look no further! This handy guide provides an on-the-job reference source for Electricians, Designers, Service Engineers, Inspectors, Builders, Students, DIY enthusiastsTopic-based chapters link areas of working practice - such as cables, installations, testing and inspection, special locations - with the specifics of the Regulations themselves. This allows quick and easy identification of the official requirements relating to the situati

  8. The Micro Wire Detector

    Energy Technology Data Exchange (ETDEWEB)

    Adeva, B.; Gomez, F.; Pazos, A.; Pfau, R.; Plo, M. E-mail: maximo.plo@cern.ch; Rodriguez, J.M.; Vazquez, P.; Labbe, J.C

    1999-10-11

    We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 {mu}m{sup 2} apertures, crossed by 25 {mu}m anode strips to which it is attached by 50 {mu}m kapton spacers. In the region where the avalanche takes place, the anode strips are suspended in the gas mixture as in a standard wire chamber. This detector exhibits high rate capability and large gains, introducing very little material. (author)

  9. Epitaxial semiconductor quantum wires.

    Science.gov (United States)

    Wu, J; Chen, Y H; Wang, Z G

    2008-07-01

    The investigation on the direct epitaxial quantum wires (QWR) using MBE or MOCVD has been persuited for more than two decades, more lengthy in history as compared with its quantum dot counterpart. Up to now, QWRs with various structural configurations have been produced with different growth methods. This is a reviewing article consisting mainly of two parts. The first part discusses QWRs of various configurations, together with laser devices based on them, in terms of the two growth mechanisms, self-ordering and self-assembling. The second part gives a brief review of the electrical and optical properties of QWRs.

  10. Analysis of pellet coating uniformity using a computer scanner.

    Science.gov (United States)

    Šibanc, Rok; Luštrik, Matevž; Dreu, Rok

    2017-11-30

    A fast method for pellet coating uniformity analysis, using a commercial computer scanner was developed. The analysis of the individual particle coating thicknesses was based on using a transparent orange colored coating layer deposited on white pellet cores. Besides the analysis of the coating thickness the information of pellet size and shape was obtained as well. Particle size dependent coating thickness and particle size independent coating variability was calculated by combining the information of coating thickness and pellet size. Decoupling coating thickness variation sources is unique to presented method. For each coating experiment around 10000 pellets were analyzed, giving results with a high statistical confidence. Proposed method was employed for the performance evaluation of classical Wurster and swirl enhanced Wurster coater operated at different gap settings and air flow rates. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. 46 CFR 111.60-11 - Wire.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Wire. 111.60-11 Section 111.60-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-11 Wire. (a) Wire must be in an enclosure. (b) Wire must be...

  12. How flatbed scanners upset accurate film dosimetry

    International Nuclear Information System (INIS)

    Van Battum, L J; Verdaasdonk, R M; Heukelom, S; Huizenga, H

    2016-01-01

    Film is an excellent dosimeter for verification of dose distributions due to its high spatial resolution. Irradiated film can be digitized with low-cost, transmission, flatbed scanners. However, a disadvantage is their lateral scan effect (LSE): a scanner readout change over its lateral scan axis. Although anisotropic light scattering was presented as the origin of the LSE, this paper presents an alternative cause. Hereto, LSE for two flatbed scanners (Epson 1680 Expression Pro and Epson 10000XL), and Gafchromic film (EBT, EBT2, EBT3) was investigated, focused on three effects: cross talk, optical path length and polarization. Cross talk was examined using triangular sheets of various optical densities. The optical path length effect was studied using absorptive and reflective neutral density filters with well-defined optical characteristics (OD range 0.2–2.0). Linear polarizer sheets were used to investigate light polarization on the CCD signal in absence and presence of (un)irradiated Gafchromic film. Film dose values ranged between 0.2 to 9 Gy, i.e. an optical density range between 0.25 to 1.1. Measurements were performed in the scanner’s transmission mode, with red–green–blue channels. LSE was found to depend on scanner construction and film type. Its magnitude depends on dose: for 9 Gy increasing up to 14% at maximum lateral position. Cross talk was only significant in high contrast regions, up to 2% for very small fields. The optical path length effect introduced by film on the scanner causes 3% for pixels in the extreme lateral position. Light polarization due to film and the scanner’s optical mirror system is the main contributor, different in magnitude for the red, green and blue channel. We concluded that any Gafchromic EBT type film scanned with a flatbed scanner will face these optical effects. Accurate dosimetry requires correction of LSE, therefore, determination of the LSE per color channel and dose delivered to the film. (paper)

  13. Corrosion of Wires on Wooden Wire-Bound Packaging Crates

    Science.gov (United States)

    Samuel L. Zelinka; Stan Lebow

    2015-01-01

    Wire-bound packaging crates are used by the US Army to transport materials. Because these crates may be exposed to harsh environments, they are dip-treated with a wood preservative (biocide treatment). For many years, zinc-naphthenate was the most commonly used preservative for these packaging crates and few corrosion problems with the wires were observed. Recently,...

  14. Improved superconducting magnet wire

    Science.gov (United States)

    Schuller, I.K.; Ketterson, J.B.

    1983-08-16

    This invention is directed to a superconducting tape or wire composed of alternating layers of copper and a niobium-containing superconductor such as niobium of NbTi, Nb/sub 3/Sn or Nb/sub 3/Ge. In general, each layer of the niobium-containing superconductor has a thickness in the range of about 0.05 to 1.5 times its coherence length (which for Nb/sub 3/Si is 41 A) with each copper layer having a thickness in the range of about 170 to 600 A. With the use of very thin layers of the niobium composition having a thickness within the desired range, the critical field (H/sub c/) may be increased by factors of 2 to 4. Also, the thin layers of the superconductor permit the resulting tape or wire to exhibit suitable ductility for winding on a magnet core. These compositions are also characterized by relatively high values of critical temperature and therefore will exhibit a combination of useful properties as superconductors.

  15. An automated alpha scanner for estimating plutonium contamination levels on FBTR fuel pin

    International Nuclear Information System (INIS)

    Bagul, D.G.; Sharma, V.P.; Benadikar, S.V.; Karnani, N.K.; Kamath, K.V.

    1995-01-01

    An automated alpha scanner has been developed for estimating plutonium contamination on SS clad fuel pins fabricated in Radiometallurgy Division for Fast Breeder Test Reactor (FBTR). The unit can detect as low as 1% of the allowed contamination limit for the fuel pin. Because of automation, large number of pins can be systematically scanned for Pu contamination with minimum radiation exposure to the operator. (author). 3 refs., 1 fig., 1 tab

  16. Wire and Packing Tape Sandwiches

    Science.gov (United States)

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  17. Inter laboratory comparison of industrial CT scanners

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; Cantatore, Angela; De Chiffre, Leonardo

    2012-01-01

    In this report results from an intercomparison of industrial CT scanners are presented. Three audit items, similar to common industrial parts, were selected for circulation: a single polymer part with complex geometry (Item 1), a simple geometry part made of two polymers (Item 2) and a miniature ...

  18. A PET scanner developed by CERN

    CERN Multimedia

    Laurent Guiraud

    1998-01-01

    This image shows a Position Emission Tomography (PET) scanner at the Hopital Cantonal Universitaire de Genève. Development of the multiwire proportional chamber at CERN in the mid-1970s was soon seen as a potential device for medical imaging. It is much more sensitive than previous devices and greatly reduced the dose of radiation received by the patient.

  19. Scanner and irradiation: optimization of protocols

    International Nuclear Information System (INIS)

    Duchemin, J.; Martine-Rollet, B.; Lienart, S.; Mobailly, M.; Florin, J.P.; Beregi, J.P.; Puech, N.

    2006-01-01

    The irradiation of the patient or the personnel increased with the arrival of the multi-detector scanners. The objective of this work is to realize a didactic poster to inform and make sensitive on the irradiation with scan so that to propose solutions of protection. (N.C.)

  20. Wire metamaterials: physics and applications.

    Science.gov (United States)

    Simovski, Constantin R; Belov, Pavel A; Atrashchenko, Alexander V; Kivshar, Yuri S

    2012-08-16

    The physics and applications of a broad class of artificial electromagnetic materials composed of lattices of aligned metal rods embedded in a dielectric matrix are reviewed. Such structures are here termed wire metamaterials. They appear in various settings and can operate from microwaves to THz and optical frequencies. An important group of these metamaterials is a wire medium possessing extreme optical anisotropy. The study of wire metamaterials has a long history, however, most of their important and useful properties have been revealed and understood only recently, especially in the THz and optical frequency ranges where the wire media correspond to the lattices of microwires and nanowires, respectively. Another group of wire metamaterials are arrays and lattices of nanorods of noble metals whose unusual properties are driven by plasmonic resonances. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Aerosols produced by evaporation of a uranium wire

    International Nuclear Information System (INIS)

    Morel, C.

    1968-03-01

    This work is devoted to the study of the aerosols formed when an uranium wire is evaporated in a normal or rarefied atmosphere, either with or without a drying agent. The heating of the wire can be either fast or slow. The first part is a study of aerosol production apparatus and of methods of measuring the aerosol. The second part presents the results obtained with various aerosols: the particles produced by the wire are less than one micron; during rapid heating, the granulometric distribution of the aerosol obeys a log-normal law; during slow heating, the distribution has two modes: one near 0.05 micron, the other close to 0.01 micron. (author) [fr

  2. Beam profile assessment in spectral CT scanners.

    Science.gov (United States)

    Anjomrouz, Marzieh; Shamshad, Muhammad; Panta, Raj K; Broeke, Lieza Vanden; Schleich, Nanette; Atharifard, Ali; Aamir, Raja; Bheesette, Srinidhi; Walsh, Michael F; Goulter, Brian P; Bell, Stephen T; Bateman, Christopher J; Butler, Anthony P H; Butler, Philip H

    2018-03-01

    In this paper, we present a method that uses a combination of experimental and modeled data to assess properties of x-ray beam measured using a small-animal spectral scanner. The spatial properties of the beam profile are characterized by beam profile shape, the angular offset along the rotational axis, and the photon count difference between experimental and modeled data at the central beam axis. Temporal stability of the beam profile is assessed by measuring intra- and interscan count variations. The beam profile assessment method was evaluated on several spectral CT scanners equipped with Medipix3RX-based detectors. On a well-calibrated spectral CT scanner, we measured an integral count error of 0.5%, intrascan count variation of 0.1%, and an interscan count variation of less than 1%. The angular offset of the beam center ranged from 0.8° to 1.6° for the studied spectral CT scanners. We also demonstrate the capability of this method to identify poor performance of the system through analyzing the deviation of the experimental beam profile from the model. This technique can, therefore, aid in monitoring the system performance to obtain a robust spectral CT; providing the reliable quantitative images. Furthermore, the accurate offset parameters of a spectral scanner provided by this method allow us to incorporate a more realistic form of the photon distribution in the polychromatic-based image reconstruction models. Both improvements of the reliability of the system and accuracy of the volume reconstruction result in a better discrimination and quantification of the imaged materials. © 2018 MARS Bioimaging Ltd. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  3. 3D Wire 2015

    DEFF Research Database (Denmark)

    Jordi, Moréton; F, Escribano; J. L., Farias

    , therefore, we’ve drawn conclusions and recommendations for future editions of the event, also generalizable to other experiences of gamification especially in events. This report details the methodology and working elements from the design phase, human resources and organization of production......This document is a general report on the implementation of gamification in 3D Wire 2015 event. As the second gamification experience in this event, we have delved deeply in the previous objectives (attracting public areas less frequented exhibition in previous years and enhance networking) and have...... proposed new ones (viralization of the event on social networks and improvement of the integration of international attendees). On the other hand we defined a set of research objectives related to the study of gamification in an eminently social place like an event. Most of the goals have been met and...

  4. Body scanners: are they dangerous for health?; Scanners corporels: dangereux pour la sante?

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-07-01

    As there is a debate about the risk of cancer and of congenital malformation associated with the use of body scanners, notably in airports, this document recalls and comments the IAEA statement on this issue. According to a study performed by this international agency, the irradiation dose is very low. But the French IRSN is more prudent and recommends not to use X ray scanner, but to look for technologies which do not use ionizing radiation

  5. Occurrence and characteristics of mutual interference between LIDAR scanners

    Science.gov (United States)

    Kim, Gunzung; Eom, Jeongsook; Park, Seonghyeon; Park, Yongwan

    2015-05-01

    The LIDAR scanner is at the heart of object detection of the self-driving car. Mutual interference between LIDAR scanners has not been regarded as a problem because the percentage of vehicles equipped with LIDAR scanners was very rare. With the growing number of autonomous vehicle equipped with LIDAR scanner operated close to each other at the same time, the LIDAR scanner may receive laser pulses from other LIDAR scanners. In this paper, three types of experiments and their results are shown, according to the arrangement of two LIDAR scanners. We will show the probability that any LIDAR scanner will interfere mutually by considering spatial and temporal overlaps. It will present some typical mutual interference scenario and report an analysis of the interference mechanism.

  6. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  7. Investigation of exploding wire in different experimental conditions

    Science.gov (United States)

    Sarkisov, Gennady; Struve, Kenneth; Rosenthal, Stephen; Sasorov, Pavel

    2001-10-01

    The initial stage of electrical explosion of thin metal wires in different experimental conditions has been investigated. A pulser (3kA, 120kV) with fast (150A/ns) and slow (20A/ns) operational modes has been used. Current, voltage, laser-streaked images on 905nm, visible light emission have been monitored during the experiment. Two-wavelengths laser shadowgraphy and interferometry with 150ps pulse duration have been used to get information about shape and electron density. Different substances, diameters, lengths, target configurations, vacuum or air environment, surface conditions, cold or hot start and influence of pulser polarity have been investigated. Energy deposition is dramatically dependent from current rate and voltage polarity. Increasing of the current rate allows more energy deposition before surface breakdown. Changing polarity of the pulser from positive to negative in vacuum results in decrease of energy deposition into the wire and change of its structure. Direction of radial electric field becomes important for initial stage of wire explosion. These results can be understood in terms of influence of electronic emissions on triggering the plasma shell around the wire. The structure of radial electric field surrounding the wire has been simulated using 2D electrostatic code. Results of experiments have been compared with 2D MHD simulations.

  8. Applications of Optical Scanners in an Academic Center.

    Science.gov (United States)

    Molinari, Carol; Tannenbaum, Robert S.

    1995-01-01

    Describes optical scanners, including how the technology works; applications in data management and research; development of instructional materials; and providing community services. Discussion includes the three basic types of optical scanners: optical character recognition (OCR), optical mark readers (OMR), and graphic scanners. A sidebar…

  9. High range resolution laser scanner with full waveform recording

    Science.gov (United States)

    Letalick, Dietmar; Larsson, Håkan; Tolt, Gustav; Allard, Lars; Wollner, Erika; Berglund, Folke

    2010-10-01

    This paper describes the development of a high resolution waveform recording laser scanner and presents results obtained with the system. When collecting 3-D data on small objects, high range and transverse resolution is needed. In particular, if the objects are partly occluded by sparse materials such as vegetation, multiple returns from a single laser pulse may limit the image quality. The ability to resolve multiple echoes depends mainly on the laser pulse width and the receiver bandwidth. With the purpose to achieve high range resolution for multiple returns, we have developed a high performance 3-D LIDAR, called HiPer, with a short pulse fibre laser (500 ps), fast detectors (70 ps rise time) and a 20 GS/s oscilloscope for fast sampling. HiPer can acquire the full waveform, which can be used for off-line processing. This paper will describe the LIDAR system and present some image examples. The signal processing will also be described, with some examples from the off-line processing and the benefit of using the complete waveform.

  10. Synthesis of chemical vapor deposition graphene on tantalum wire for supercapacitor applications

    Energy Technology Data Exchange (ETDEWEB)

    Li, Mingji, E-mail: limingji@163.com [Tianjin Key Laboratory of Film Electronic and Communicate Devices, School of Electronics Information Engineering, Tianjin University of Technology, Tianjin 300384 (China); Guo, Wenlong [Tianjin Key Laboratory of Film Electronic and Communicate Devices, School of Electronics Information Engineering, Tianjin University of Technology, Tianjin 300384 (China); Li, Hongji, E-mail: hongjili@yeah.net [Tianjin Key Laboratory of Organic Solar Cells and Photochemical Conversion, School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin 300384 (China); Xu, Sheng [School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072 (China); Qu, Changqing; Yang, Baohe [Tianjin Key Laboratory of Film Electronic and Communicate Devices, School of Electronics Information Engineering, Tianjin University of Technology, Tianjin 300384 (China)

    2014-10-30

    Highlights: • The capacitance of graphene/tantalum (Ta) wire electrodes is firstly reported. • Graphene was grown on the Ta surface by hot-filament chemical vapor deposition. • Graphene/Ta wire structure is favorable for fast ion and electron transfer. • The graphene/Ta wire electrode shows high capacitive properties. - Abstract: This paper studies the synthesis and electrochemical characterization of graphene/tantalum (Ta) wires as high-performance electrode material for supercapacitors. Graphene on Ta wires is prepared by the thermal decomposition of methane under various conditions. The graphene nanosheets on the Ta wire surface have an average thickness of 1.3–3.4 nm and consist typically of a few graphene monolayers, and TaC buffer layers form between the graphene and Ta wire. A capacitor structure is fabricated using graphene/Ta wire with a length of 10 mm and a diameter of 0.6 mm as the anode and Pt wire of the same size as the cathode. The electrochemical behavior of the graphene/Ta wires as supercapacitor electrodes is characterized by cyclic voltammetry, galvanostatic charge/discharge, and electrochemical impedance spectroscopy in 1 M Na{sub 2}SO{sub 4} aqueous electrolyte. The as-prepared graphene/Ta electrode has highest capacitance of 345.5 F g{sup −1} at current density of 0.5 A g{sup −1}. The capacitance remains at about 84% after 1000 cycles at 10 A g{sup −1}. The good electrochemical performance of the graphene/Ta wire electrode is attributed to the unique nanostructural configuration, high electrical conductivity, and large specific surface area of the graphene layer. This suggests that graphene/Ta wire electrode materials have potential applications in high-performance energy storage devices.

  11. Get Mobile – The Smartphone Brain Scanner

    DEFF Research Database (Denmark)

    Stahlhut, Carsten; Stopczynski, Arkadiusz; Petersen, Michael Kai

    This demonstration will provide live-interaction with a smartphone brain scanner consisting of a low-cost wireless 14-channel EEG headset (Emotiv Epoc) and a mobile device. With our system it is possible to perform real-time functional brain imaging on a smartphone device, including stimulus...... delivery, data acquisition, logging, brain state decoding, and 3D visualization of the cortical EEG sources. Implementation of the smartphone brain scanner is based on the Qt framework and benefits from the cross-platform support of multiple hardware platforms (smartphones, tablet devices, netbooks and PCs......) that are based on Linux operating systems. Thus our system runs on multiple platforms, including Maemo/MeeGo based smartphones, Android-based smartphones and tablet devices....

  12. Financing technical-medical activities. CT scanner example in France (1986)

    International Nuclear Information System (INIS)

    Meyer, C.; Lefaure, C.; Fagnani, F.

    1988-01-01

    To analyze the french methods for financing technical-medical activities as CT scanners, and to assess if they can face, or not, the management constraints of such activities a financial simulation has been executed. First, current expenditures are totalized (including depreciations and financial charges) with variations according to the numer of examinations per year. Costs are classified especially according to fixed and variable charges: the weight of fixed charges, especially equipment charges, is the most significant. It's very high in yearly expenditures. Most, that involves a very fast decreasing cost with increasing number of procedures. Second, consequences of such accounts are analyzed: - on private CT scanners, Payed with a charge per examination whatever would be the factor's cost; - on public CT scanners, payed with an annual allowance; in this case charges equal receipts whatever would be the cost for a procedure. Third, a break point is defined; either the annual activity is higher: there would be an excedent; either it is lower: there would be a deficit. Then, those results are reported to CT-scanners activity's data in France (1986). After all, financing systems themselves, are discussed and a few hypothesis to explain those desadjustments between charges and their financing way are suggested [fr

  13. 2D X-ray scanner and its uses in laboratory reservoir characterization measurements

    Energy Technology Data Exchange (ETDEWEB)

    Maloney, D.; Doggett, K.

    1997-08-01

    X-ray techniques are used in petroleum laboratories for a variety of reservoir characterization measurements. This paper describes the configuration of a 2D X-ray scanner and many of the ways in which it simplifies and improves accuracy`s of laboratory measurements. Linear X-ray scanners are most often used to provide descriptions of fluid saturations within core plugs during flow tests. We configured our linear scanner for both horizontal and vertical movement. Samples can be scanned horizontally, vertically, or according to horizontal and vertical grids. X-ray measurements are fast, allowing measurements of two- and three-phase fluid saturations during both steady- and unsteady-state flow processes. Rock samples can be scanned while they are subjected to stress, pore pressure, and temperature conditions simulating those of a petroleum reservoir. Many types of measurements are possible by selecting appropriate X-ray power settings, dopes, filters, and collimator configurations. The scanner has been used for a variety of applications besides fluid saturation measurements. It is useful for measuring porosity distributions in rocks, concentrations of X-ray dopes within flow streams during tracer tests, gap widths in fracture flow cells, fluid interface levels in PVT cells and fluid separators, and other features and phenomena.

  14. Imaging Scanner Usage in Radiochemical Purity Test

    International Nuclear Information System (INIS)

    Norhafizah Othman; Yahaya Talib; Wan Hamirul Bahrin Wan Kamal

    2011-01-01

    Imaging Scanner model BIOSCAN AR-2000 has been used in the radiochemical purity test for the product of Mo-99/ Tc-99m generator. Result from this test was produced directly where the percentage of pertechnetate was calculated based on width peak area by thin layer chromatography. This paperwork will explain the function, procedure, calibration of the instrument and discussed the advantages compared to the previous method. (author)

  15. Fast radiographic systems

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1984-08-01

    Industrial radiography can be performed with shorter exposure times, when instead of X-ray film with lead intensifying screens the radiographic paper with fluorescent screen is used. With paper radiography one can obtain lower material, equipment, and labor costs, shorter exposure and processing times, and easier radiation protection. The speed of the radiographic inspection can also be increased by the use of fluorometallic intensifying screens together with a special brand of X-ray film. Before accepting either of the two fast radiographic systems one must be sure that they can produce radiographs of adequate image quality. Therefore an investigation was performed on that subject using ISO wire IQI's and ASTM penetrameters. The radiographic image quality was tested for aluminium and steel up to 30 mm thick using various brands of radiographic paper and X-ray film with fluorometallic screens and comparing them with fast X-ray films with lead screens. Both systems give satisfactory results. (author)

  16. Software development for modeling positrons emission tomograph scanners

    International Nuclear Information System (INIS)

    Vieira, Igor Fagner

    2013-01-01

    The Geant4 Application for Tomographic Emission (GATE) is an international platform recognized and used to develop Computational Model Exposure (CME) in the context of Nuclear Medicine, although currently there are dedicated modules for applications in Radiotherapy and Computed Tomography (CT). GATE uses Monte Carlo (MC) methods, and has a scripting language of its own. The writing of scripts for simulation of a PET scanner in GATE involves a number of interrelated steps, and the accuracy of the simulation is dependent on the correct setup of the geometries involved, since the physical processes depend on them, as well as the modeling of electronic detectors in module Digitizer, for example. The manual implementation of this setup can be a source of errors, especially for users without experience in the field of simulations or without any previous knowledge of a programming language, and also due to the the fact that the modeling process in GATE still remains bounded to LINUX / UNIX based systems, an environment only familiar to a few. This becomes an obstacle for beginners and prevents the use of GATE by a larger number of users interested in optimizing their experiments and/or clinical protocols through a more accessible, fast and friendly application. The objective of this work is therefore to develop a user-friendly software for the modeling of Positron Emission Tomography called GUIGATE (Graphical User Interface for GATE), with specific modules dedicated to quality control in PET scanners. The results exhibit the features available in this first version of GUIGATE, present in a set of windows that allow users to create their input files, perform and display in real time the model and analyze its output file in a single environment, allowing so intuitively access the entire architecture of the GATE simulation and to CERN's data analyzer, the ROOT. (author)

  17. Laser measuring scanners and their accuracy limits

    Science.gov (United States)

    Jablonski, Ryszard

    1993-09-01

    Scanning methods have gained the greater importance for some years now due to a short measuring time and wide range of application in flexible manufacturing processes. This paper is a summing up of the autho?s creative scientific work in the field of measuring scanners. The research conducted allowed to elaborate the optimal configurations of measuring systems based on the scanning method. An important part of the work was the analysis of a measuring scanner - as a transducer of an angle rotation into the linear displacement which resulted in obtaining its much higher accuracy and finally in working out a measuring scanner eliminating the use of an additional reference standard. The completion of the work is an attempt to determine an attainable accuracy limit of scanning measurement of both length and angle. Using a high stability deflector and a corrected scanning lens one can obtain the angle determination over 30 (or 2 mm) to an accuracy 0 (or 0 tm) when the measuring rate is 1000 Hz or the range d60 (4 mm) with accuracy 0 " (0 jim) and measurement frequency 6 Hz.

  18. Scanner-based macroscopic color variation estimation

    Science.gov (United States)

    Kuo, Chunghui; Lai, Di; Zeise, Eric

    2006-01-01

    Flatbed scanners have been adopted successfully in the measurement of microscopic image artifacts, such as granularity and mottle, in print samples because of their capability of providing full color, high resolution images. Accurate macroscopic color measurement relies on the use of colorimeters or spectrophotometers to provide a surrogate for human vision. The very different color response characteristics of flatbed scanners from any standard colorimetric response limits the utility of a flatbed scanner as a macroscopic color measuring device. This metamerism constraint can be significantly relaxed if our objective is mainly to quantify the color variations within a printed page or between pages where a small bias in measured colors can be tolerated as long as the color distributions relative to the individual mean values is similar. Two scenarios when converting color from the device RGB color space to a standardized color space such as CIELab are studied in this paper, blind and semi-blind color transformation, depending on the availability of the black channel information. We will show that both approaches offer satisfactory results in quantifying macroscopic color variation across pages while the semi-blind color transformation further provides fairly accurate color prediction capability.

  19. 49 CFR 393.28 - Wiring systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Wiring systems. 393.28 Section 393.28... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.28 Wiring systems. Electrical wiring shall be installed and maintained to conform to SAE J1292—Automobile, Truck, Truck-Tractor...

  20. Particle discrimination by an automatic scanner for nuclear emulsion plates

    International Nuclear Information System (INIS)

    Heinecke, W.; Fischer, B.E.

    1976-01-01

    An automatic scanner for nuclear emulsion plates has been improved by adding particle discrimination. By determination of the mean luminosity of tracks in darkfield illumination in addition to the track length a clear discrimination has been obtained, at least for lighter particles. The scanning speed of the original automatic scanner has not been reduced. The scanner works up to 200 times faster than a human scanner. Besides the particle discrimination the determination of the mean track luminosity led to a lower perturbation sensitivity with respect to a high background of accidentally developed silvergrains, scratches in emulsion etc. The reproducibility of the results obtained by the automatic scanner is better than 5%. (Auth.)

  1. Modeling birds on wires.

    Science.gov (United States)

    Aydoğdu, A; Frasca, P; D'Apice, C; Manzo, R; Thornton, J M; Gachomo, B; Wilson, T; Cheung, B; Tariq, U; Saidel, W; Piccoli, B

    2017-02-21

    In this paper we introduce a mathematical model to study the group dynamics of birds resting on wires. The model is agent-based and postulates attraction-repulsion forces between the interacting birds: the interactions are "topological", in the sense that they involve a given number of neighbors irrespective of their distance. The model is first mathematically analyzed and then simulated to study its main properties: we observe that the model predicts birds to be more widely spaced near the borders of each group. We compare the results from the model with experimental data, derived from the analysis of pictures of pigeons and starlings taken in New Jersey: two different image elaboration protocols allow us to establish a good agreement with the model and to quantify its main parameters. We also discuss the potential handedness of the birds, by analyzing the group organization features and the group dynamics at the arrival of new birds. Finally, we propose a more refined mathematical model that describes landing and departing birds by suitable stochastic processes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Preliminary study of Rayleigh-Taylor instability in wire-array Z-pinch

    International Nuclear Information System (INIS)

    He Kaihui; Feng Kaiming; Li Qiang; Gao Chunming

    2000-01-01

    It is important to research into the MHD Rayleigh-Taylor instability developed in Z-pinch implosion. A snowplough model of the single wire Z-pinch is presented. The perturbation amplitude of Rayleigh-Taylor instability in the wire-array Z-pinch is analyzed quantitatively. Sheared axial flow is put forward to mitigate and reduce the Rayleigh-Taylor instability. And other approaches used to mitigate MHD instability in such a super-fast process are explored

  3. Topology Optimized Photonic Wire Splitters

    DEFF Research Database (Denmark)

    Frandsen, Lars Hagedorn; Borel, Peter Ingo; Jensen, Jakob Søndergaard

    2006-01-01

    Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm.......Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm....

  4. Composite conductor containing superconductive wires

    Energy Technology Data Exchange (ETDEWEB)

    Larson, W.L.; Wong, J.

    1974-03-26

    A superconductor cable substitute made by coworking multiple rods of superconductive niobium--titanium or niobium--zirconium alloy with a common copper matrix to extend the copper and rods to form a final elongated product which has superconductive wires distributed in a reduced cross-section copper conductor with a complete metallurgical bond between the normal-conductive copper and the superconductor wires contained therein is described. The superconductor cable can be in the form of a tube.

  5. 30 CFR 75.701-4 - Grounding wires; capacity of wires.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity of wires. 75.701-4... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.701-4 Grounding wires; capacity of wires. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames...

  6. 1 mil gold bond wire study.

    Energy Technology Data Exchange (ETDEWEB)

    Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.; Rutherford, Brian Milne

    2013-05-01

    In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, the gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.

  7. HTS Wire Development Workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The 1994 High-Temperature Superconducting Wire Development Workshop was held on February 16--17 at the St. Petersburg Hilton and Towers in St. Petersburg, Florida. The meeting was hosted by Florida Power Corporation and sponsored by the US Department of Energy`s Superconductivity Program for Electric Power Systems. The meeting focused on recent high-temperature superconducting wire development activities in the Department of Energy`s Superconductivity Systems program. The meeting opened with a general discussion on the needs and benefits of superconductivity from a utility perspective, the US global competitiveness position, and an outlook on the overall prospects of wire development. The meeting then focused on four important technology areas: Wire characterization: issues and needs; technology for overcoming barriers: weak links and flux pinning; manufacturing issues for long wire lengths; and physical properties of HTS coils. Following in-depth presentations, working groups were formed in each technology area to discuss the most important current research and development issues. The working groups identified research areas that have the potential for greatly enhancing the wire development effort. These areas are discussed in the summary reports from each of the working groups. This document is a compilation of the workshop proceedings including all general session presentations and summary reports from the working groups.

  8. A new wire chamber front-end system, based on the ASD-8 B chip

    Energy Technology Data Exchange (ETDEWEB)

    Kruesemann, B.A.M. E-mail: kruesemann@kvi.nl; Bassini, R.; Ellinghaus, F.; Frekers, D.; Hagemann, M.; Hannen, V.M.; Heynitz, H. von; Heyse, J.; Rakers, S.; Sohlbach, H.; Woertche, H.J

    1999-07-11

    The Focal-Plane Polarimeter (FPP) for the Big-Bite Spectrometer van den Berg (Nucl. Instr. and Meth. B 99 (1995) 637ff) at the KVI requires the read-out of four large-area MWPCs and two VDCs with 3872 wires in total. The EUROSUPERNOVA collaboration (SNOVA) developed a digital 16 channel preamplifier front-end board, housing two amplifier-shaper-discriminatorchips ASD-8 B. The main features of this board are a fast single-wire readout, a high integration density, a low power consumption and compatibility to common instrumentation standards. The board represents the first successfully running application of the ASD-8 for wire chamber readout. (author)

  9. A new wire chamber front-end system, based on the ASD-8 B chip

    CERN Document Server

    Kruesemann, B A M; Ellinghaus, F; Frekers, D; Hagemann, M; Hannen, V M; Heynitz, H V; Heyse, J; Rakers, S; Sohlbach, H; Wörtche, H J

    1999-01-01

    The Focal-Plane Polarimeter (FPP) for the Big-Bite Spectrometer van den Berg (Nucl. Instr. and Meth. B 99 (1995) 637ff) at the KVI requires the read-out of four large-area MWPCs and two VDCs with 3872 wires in total. The EUROSUPERNOVA collaboration (SNOVA) developed a digital 16 channel preamplifier front-end board, housing two amplifier-shaper-discriminatorchips ASD-8 B. The main features of this board are a fast single-wire readout, a high integration density, a low power consumption and compatibility to common instrumentation standards. The board represents the first successfully running application of the ASD-8 for wire chamber readout. (author)

  10. Relativistic electron transport in wire and foil targets driven by intense short pulse lasers

    Science.gov (United States)

    Mason, R. J.; Stephens, R. B.; Wei, M.; Freeman, R. R.; Hill, J.; van Woerkom, L. D.

    2006-10-01

    We model intense laser driven electron transport in wires and foils with the new implicit hybrid code e-PLAS. We focus on background plasma heating for Fast Ignitor applications. The model tracks collisional relativistic PIC electrons undergoing scatter and drag in a background plasma of colliding cold electron and ion Eulerian fluids. Application to 10 μm diameter, 250 μm long, fully ionized carbon wires with an attached cone [Kodama et al. Nature 432 1005 (2004)], exposed to 1 ps, 10^19 W/cm^2 pulses in a 30 μm centered spot, directly calculates resistive Joule heating of the background electrons in the wire to 1.7 KeV. 150 MG magnetic fields arise at the wire surfaces corresponding to hot electron flow outside the wire and a return electron flow just within it. Shorter wires (25 μm) exhibit hot electron recycling. Preliminary simulations indicate that reduction of the cone to a 30 μm diameter nail head produces little change in these results. We also report on tapered wires, wires attached to foils, and the modifying effects of pre-plasma on electron transport into the foils.

  11. Laser Scanner 3D Applicazioni, metodologie e potenzialità del rilevamento con laser scanner terrestre

    Directory of Open Access Journals (Sweden)

    Giorgio Vassena

    2007-03-01

    Full Text Available Con un po’ di ritardo riportiamo il resoconto della giornata che si è svolta lo scorso 28 maggio presso l’Università degli Studi di Brescia dedicata al laser scanner terrestre. Con l’intervento di geologi, tecnici, ingegneri e accademici sono stati analizzati casi pratici e concreti in cui l’integrazione del laser scanner con le tecniche di rilevamento classico (fotografiche, topografichee GPS è stata fondamentale per la riuscita finale del lavoro.

  12. Whole body X-ray CT scanner SCT-3000T series

    International Nuclear Information System (INIS)

    Saida, Teruhiko; Takemura, Kunihiko; Suzuki, Satoru; Sato, Yukio; Kawamoto, Yasushi; Goto, Mitsuhiro; Mishina, Yukio

    1989-01-01

    The whole body CT scanner, SCT-3000T series which improve the patient through-put and the diagnostic capability, has been developed. In the SCT-3000T series CT scanners, the great reduction of the reconstruction time and the scan cycle time has been achieved by developing the special purpose hardwares for image reconstruction such as the fast front end processor, the intelligent buffer memory. In case of the SCT-3000TX routine conditions of operation, including 3.0 sec scan, table increment, image reconstruction and image filing, the scan cycle time is about 9 seconds which is the shortest value among the competitive models. Furthermore, the higher diagnostic capability has been provided with the system, by adopting the 1024 x 1024 display matrices, and by developing the diagnostic softwares such as 3-D display program, arbitrary curved plane MPR program, r-CBF measurement program and etc. (author)

  13. Recent advances in dental optics - Part I: 3D intraoral scanners for restorative dentistry

    Science.gov (United States)

    Logozzo, Silvia; Zanetti, Elisabetta M.; Franceschini, Giordano; Kilpelä, Ari; Mäkynen, Anssi

    2014-03-01

    Intra-oral scanning technology is a very fast-growing field in dentistry since it responds to the need of an accurate three-dimensional mapping of the mouth, as required in a large number of procedures such as restorative dentistry and orthodontics. Nowadays, more than 10 intra-oral scanning devices for restorative dentistry have been developed all over the world even if only some of those devices are currently available on the market. All the existing intraoral scanners try to face with problems and disadvantages of traditional impression fabrication process and are based on different non-contact optical technologies and principles. The aim of this publication is to provide an extensive review of existing intraoral scanners for restorative dentistry evaluating their working principles, features and performances.

  14. Mapping soil features from multispectral scanner data

    Science.gov (United States)

    Kristof, S. J.; Zachary, A. L.

    1974-01-01

    In being able to identify quickly gross variations in soil features, the computer-aided classification of multispectral scanner data can be an effective aid to soil surveying. Variations in soil tone are easily seen as well as variations in features related to soil tone, e.g., drainage patterns and organic matter content. Changes in surface texture also affect the reflectance properties of soils. Inasmuch as conventional soil classes are based on both surface and subsurface soil characteristics, the technique described here can be expected only to augment and not replace traditional soil mapping.

  15. Applications of the scanner in osteoarticular pathology

    Energy Technology Data Exchange (ETDEWEB)

    Bard, M.; Morvan, G.; Busson, J.; Massare, C.

    1986-03-01

    The authors take stock of current applications of the scanner in osteoarticular pathology. At first (1978-1983 approximately), only the vertebral column could be studied by this technique. Now, almost all the osteoarticular system is susceptible to study. Established examples are: study of the sacrum, of the traumatized acetabulum, of the femoropatellar apparatus, and measurement of torsion in the lower limbs. New applications are: study of the back of the foot, of the patellar cartilage, of the glenoid cavity, of the bones and soft parts of the hand, three-dimensional reconstructions, scanning radiology. The authors index and analyse these new techniques.

  16. Image quality assessment of LaBr3-based whole-body 3D PET scanners: a Monte Carlo evaluation

    International Nuclear Information System (INIS)

    Surti, S; Karp, J S; Muehllehner, G

    2004-01-01

    The main thrust for this work is the investigation and design of a whole-body PET scanner based on new lanthanum bromide scintillators. We use Monte Carlo simulations to generate data for a 3D PET scanner based on LaBr 3 detectors, and to assess the count-rate capability and the reconstructed image quality of phantoms with hot and cold spheres using contrast and noise parameters. Previously we have shown that LaBr 3 has very high light output, excellent energy resolution and fast timing properties which can lead to the design of a time-of-flight (TOF) whole-body PET camera. The data presented here illustrate the performance of LaBr 3 without the additional benefit of TOF information, although our intention is to develop a scanner with TOF measurement capability. The only drawbacks of LaBr 3 are the lower stopping power and photo-fraction which affect both sensitivity and spatial resolution. However, in 3D PET imaging where energy resolution is very important for reducing scattered coincidences in the reconstructed image, the image quality attained in a non-TOF LaBr 3 scanner can potentially equal or surpass that achieved with other high sensitivity scanners. Our results show that there is a gain in NEC arising from the reduced scatter and random fractions in a LaBr 3 scanner. The reconstructed image resolution is slightly worse than a high-Z scintillator, but at increased count-rates, reduced pulse pileup leads to an image resolution similar to that of LSO. Image quality simulations predict reduced contrast for small hot spheres compared to an LSO scanner, but improved noise characteristics at similar clinical activity levels

  17. Circumference estimation using 3D-whole body scanners and shadow scanner

    NARCIS (Netherlands)

    Daanen, H.A.M.

    1998-01-01

    Clothing designers and manufacturers use traditional body dimensions as their basis. When 3D-whole body scanners are introduced to determine the body dimensions, a conversion has to be made, since scan determined circumference measures are slightly larger than the traditional values. This pilot

  18. A 3D airborne ultrasound scanner

    Science.gov (United States)

    Capineri, L.; Masotti, L.; Rocchi, S.

    1998-06-01

    This work investigates the feasibility of an ultrasound scanner designed to reconstruct three-dimensional profiles of objects in air. There are many industrial applications in which it is important to obtain quickly and accurately the digital reconstruction of solid objects with contactless methods. The final aim of this project was the profile reconstruction of shoe lasts in order to eliminate the mechanical tracers from the reproduction process of shoe prototypes. The feasibility of an ultrasonic scanner was investigated in laboratory conditions on wooden test objects with axial symmetry. A bistatic system based on five airborne polyvinylidenedifluoride (PVDF) transducers was mechanically moved to emulate a cylindrical array transducer that can host objects of maximum width and height 20 cm and 40 cm respectively. The object reconstruction was based on a simplified version of the synthetic aperture focusing technique (SAFT): the time of flight (TOF) of the first in time echo for each receiving transducer was taken into account, a coarse spatial sampling of the ultrasonic field reflected on the array transducer was delivered and the reconstruction algorithm was based on the ellipsoidal backprojection. Measurements on a wooden cone section provided submillimetre accuracy in a controlled environment.

  19. Interferometric Laser Scanner for Direction Determination

    Directory of Open Access Journals (Sweden)

    Gennady Kaloshin

    2016-01-01

    Full Text Available In this paper, we explore the potential capabilities of new laser scanning-based method for direction determination. The method for fully coherent beams is extended to the case when interference pattern is produced in the turbulent atmosphere by two partially coherent sources. The performed theoretical analysis identified the conditions under which stable pattern may form on extended paths of 0.5–10 km in length. We describe a method for selecting laser scanner parameters, ensuring the necessary operability range in the atmosphere for any possible turbulence characteristics. The method is based on analysis of the mean intensity of interference pattern, formed by two partially coherent sources of optical radiation. Visibility of interference pattern is estimated as a function of propagation pathlength, structure parameter of atmospheric turbulence, and spacing of radiation sources, producing the interference pattern. It is shown that, when atmospheric turbulences are moderately strong, the contrast of interference pattern of laser scanner may ensure its applicability at ranges up to 10 km.

  20. Wire Rupture Optimization in Wire Electrical Discharge Machining using Taguchi Approach

    Directory of Open Access Journals (Sweden)

    Maher Ibrahem

    2017-01-01

    Full Text Available Wire electrical discharge machining (WEDM is one of the most important nontraditional machining process that is well-known for cutting difficult to machine materials. The wire electrode along with machining parameters control the WEDM process. This research work focuses on optimizing WEDM parameters using Taguchi technique to minimize wire rupture. Experiments have been done using the L18 orthogonal array. Each experiment is repeated three times to ensure accurate readings of the wire rupture. The statistical methods of signal to noise ratio (S/N ratio is applied to study effects of peak current, pulse width, charging time, wire speed, and wire tension on wire rupture. As a results, the peak current, pulse width, and wire tension have the most significant effect on wire rupture followed by charging time and wire speed. The developed analysis can be used in the metal cutting field to identify the optimum machining parameters for less wire rupture.

  1. Enhancing wire-composite bond strength of bonded retainers with wire surface treatment.

    Science.gov (United States)

    Oesterle, L J; Shellhart, W C; Henderson, S

    2001-06-01

    Bonded orthodontic retainers with wires embedded in composite resin are commonly used for orthodontic retention. The purpose of this study was to test, in vitro, various wire surface treatments to determine the optimal method of enhancing the wire-composite bond strength. Coaxial wires and stainless steel wires with different surface treatments were bonded to bovine enamel and then pulled along their long axes with an Instron universal testing machine. Wire surface treatments included placing a right-angle bend in the wire, microetching the wire, and treating the wire with adhesion promoters; combinations of treatments were also examined. The results demonstrated a 24-fold increase in the wire-composite bond strength of wire that was microetched (sandblasted), compared with that of untreated straight wire. The difference between the amount of force required to break the bond produced by microetching alone (246.1 +/- 46.0 MPa) and that required for the bonds produced by the retentive bend (87.8 +/- 16.3 MPa), the adhesion promoters (silane, 11.0 +/- 3.1 MPa; Metal Primer, 28.5 +/- 15.8 MPa), or for any combination of surface treatments, was statistically significant. Microetching a stainless steel wire produced a higher wire-composite bond strength than that obtained from a coaxial wire (113.5 +/- 27.5 MPa). The results of this study indicate that microetching or sandblasting a stainless steel wire significantly increases the strength of the wire-composite bond.

  2. SCT-4800T whole body X-ray CT scanner

    International Nuclear Information System (INIS)

    Okumura, Yoshitaka; Sato, Yukio; Kuwahara, Hiroshi

    1994-01-01

    A whole body X-ray CT scanner, the SCT-4800T (trade name: INTELLECT series), has been developed. This system is the first CT scanner that is combined with general radiographic functions. The general radiographic functions include a patient couch with film casette and several tube support systems along with the CT scanner. This newly designed CT scanner also features a compact and light-weight gantry with a 700 mm diameter apperture and user-friendly operater's console. The SCT-4800T brings a new level of patient and operator comfort to the emergency radiology examination site. (author)

  3. A Compact Vertical Scanner for Atomic Force Microscopes

    Directory of Open Access Journals (Sweden)

    Jae Hong Park

    2010-11-01

    Full Text Available A compact vertical scanner for an atomic force microscope (AFM is developed. The vertical scanner is designed to have no interference with the optical microscope for viewing the cantilever. The theoretical stiffness and resonance of the scanner are derived and verified via finite element analysis. An optimal design process that maximizes the resonance frequency is performed. To evaluate the scanner’s performance, experiments are performed to evaluate the travel range, resonance frequency, and feedback noise level. In addition, an AFM image using the proposed vertical scanner is generated.

  4. Put Your Cable Wiring to the Test.

    Science.gov (United States)

    Day, C. William

    2001-01-01

    Discusses why schools and universities should use testing procedures in any wire bid specification for cable wiring and also know how experienced the installers are in testing and installing structured cabling systems. Key cabling terms are included. (GR)

  5. Novel Wiring Technologies for Aerospace Applications

    Science.gov (United States)

    Gibson, Tracy L.; Parrish, Lewis M.

    2014-01-01

    Because wire failure in aerospace vehicles could be catastrophic, smart wiring capabilities have been critical for NASA. Through the years, researchers at Kennedy Space Center (KSC) have developed technologies, expertise, and research facilities to meet this need. In addition to aerospace applications, NASA has applied its knowledge of smart wiring, including self-healing materials, to serve the aviation industry. This webinar will discuss the development efforts of several wiring technologies at KSC and provide insight into both current and future research objectives.

  6. Clinical bending of nickel titanium wires

    OpenAIRE

    Stephen Chain; Priyank Seth; Namrata Rastogi; Kenneth Tan; Mayank Gupta; Richa Singh

    2015-01-01

    Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our invento...

  7. Towards Unconventional Applications of Wire Bonding

    OpenAIRE

    Schröder, Stephan

    2018-01-01

    This thesis presents novel heterogeneous integration approaches of wire materials to fabricated and package MEMS devices by exploring unconventional applications of wire bonding technology. Wire bonding, traditionally endemic in the realm of device packaging to establish electrical die-to-package interconnections, is an attractive back-end technology, offering promising features, such as high throughput, flexibility and placement accuracy. Exploiting the advantages of state-of-the-art wire bo...

  8. Different mechanical properties in Seldinger guide wires

    Directory of Open Access Journals (Sweden)

    Wolfram Schummer

    2015-01-01

    Full Text Available Background and Aims: Most central venous catheters are placed using Seldinger guide wires. EN ISO 11070 is the guideline for testing guide wire flexing performance and tensile strength, and we can safely assume that guide wires in use meet these requirements. Unfortunately, EN ISO 11070 guidelines do not reflect the clinical requirements and we continue to see mechanical failures and their associated complications. Material and Methods: This in vitro study was performed in an accredited laboratory. With regard to flexing, we: (1 Established the minimum flexing performance needed to meet clinical requirements, (2 developed flexing performance tests which mimic clinical requirement, and (3 evaluated the mechanical properties of various guide wires relative to these requirements. With regard to tensile strength, we used the testing method prescribed in ISO 11070, but did not end the test at 5 Newton (N. We continued until the guide wire was damaged, or we reached maximum tractive force. We then did a wire-to-wire comparison. We examined two basic wire constructions, monofil and core and coil. Results: Tensile strength: All wires tested, except one, met EN ISO 11070 requirements for 5 N tensile strength. The mean of the wire types tested ranged from 15.06 N to 257.76 N. Flexing performance: None of the wires kinked. The monofil had no evidence of bending. Two core/coil wires displayed minor bending (angle 1.5°. All other wires displayed bending angles between 22.5° and 43.0°. Conclusion: We recommend that: (1 Clinicians use guide wires with high-end mechanical properties, (2 EN ISO 11070 incorporate our flexing test into their testing method, raise the flexing requirement to kink-proof, (3 and raise the tensile strength requirement to a minimum of 30 N, and (3 all manufacturers and suppliers be required to display mechanical properties of all guide wire, and guide wire kits sold.

  9. Vocational Preparation Curriculum: Electrical Wiring.

    Science.gov (United States)

    Usoro, Hogan

    This document is a curriculum guide for instructors teaching vocational preparation for electrical wiring to special needs students. The purpose of the curriculum guide is to provide minimum skills for disadvantaged and handicapped students entering the mainstream; to supplement vocational skills of those students already in a regular training…

  10. Transparency in nanophotonic quantum wires

    International Nuclear Information System (INIS)

    Singh, Mahi R

    2009-01-01

    We have studied the quantum optics of a photonic quantum nanowire doped with an ensemble of three-level nanoparticles. The wire is made from two photonic crystals A and B. Crystal A is embedded within crystal B and acts as a photonic nanowire. It is considered that the conduction band of crystal A lies below that of crystal B. As a result, photons are confined in crystal A and are reflected from crystal B. The bound states of the confined photons are calculated using the transfer matrix method. It is found that the number of bound states in the wire depends on the size of the wire and the energy difference between the conduction band extrema of crystals A and B. The absorption coefficient of the system has also been calculated using the Schroedinger equation method. It is considered that the nanoparticles interact with the photonic bound states. Numerical simulations show that when one of the resonance energies lies near the bound state, the system becomes transparent. However, when the resonance energy lies away from the bound state the crystal reverts to an absorbing state. Similarly, when the radius of the dielectric spheres is changed the location of the transparency peak is shifted. This means that the present system can be switched between two states by changing the size of the wire and the transition energy. These findings can be used to make new types of optical devices.

  11. Health care's 100 most wired.

    Science.gov (United States)

    Solovy, A; Serb, C

    1999-02-01

    They're wired all right, and America's 100 most techno-savvy hospitals and health systems share one more thing: a commitment to using technology to link with employees, patients, suppliers, and insurers. "We want to be a health care travel agency for our community," says one chief information officer. "And we see Internet technology as a key."

  12. Scanner OPC signatures: automatic vendor-to-vendor OPE matching

    Science.gov (United States)

    Renwick, Stephen P.

    2009-03-01

    As 193nm lithography continues to be stretched and the k1 factor decreases, optical proximity correction (OPC) has become a vital part of the lithographer's tool kit. Unfortunately, as is now well known, the design variations of lithographic scanners from different vendors cause them to have slightly different optical-proximity effect (OPE) behavior, meaning that they print features through pitch in distinct ways. This in turn means that their response to OPC is not the same, and that an OPC solution designed for a scanner from Company 1 may or may not work properly on a scanner from Company 2. Since OPC is not inexpensive, that causes trouble for chipmakers using more than one brand of scanner. Clearly a scanner-matching procedure is needed to meet this challenge. Previously, automatic matching has only been reported for scanners of different tool generations from the same manufacturer. In contrast, scanners from different companies have been matched using expert tuning and adjustment techniques, frequently requiring laborious test exposures. Automatic matching between scanners from Company 1 and Company 2 has remained an unsettled problem. We have recently solved this problem and introduce a novel method to perform the automatic matching. The success in meeting this challenge required three enabling factors. First, we recognized the strongest drivers of OPE mismatch and are thereby able to reduce the information needed about a tool from another supplier to that information readily available from all modern scanners. Second, we developed a means of reliably identifying the scanners' optical signatures, minimizing dependence on process parameters that can cloud the issue. Third, we carefully employed standard statistical techniques, checking for robustness of the algorithms used and maximizing efficiency. The result is an automatic software system that can predict an OPC matching solution for scanners from different suppliers without requiring expert intervention.

  13. Multi-anode wire straw tube tracker

    International Nuclear Information System (INIS)

    Oh, S.H.; Ebenstein, W.L.; Wang, C.W.

    2011-01-01

    We report on a test of a straw tube detector design having several anode (sense) wires inside a straw tube. The anode wires form a circle inside the tube and are read out independently. This design could solve several shortcomings of the traditional single wire straw tube design such as double hit capability and stereo configuration.

  14. Home and School Technology: Wired versus Wireless.

    Science.gov (United States)

    Van Horn, Royal

    2001-01-01

    Presents results of informal research on smart homes and appliances, structured home wiring, whole-house audio/video distribution, hybrid cable, and wireless networks. Computer network wiring is tricky to install unless all-in-one jacketed cable is used. Wireless phones help installers avoid pre-wiring problems in homes and schools. (MLH)

  15. On the preparation of superconducting wires

    International Nuclear Information System (INIS)

    Topare, R.J.; Chinchure, A.D.; Shah, S.S.; Hadole, G.B.

    1993-01-01

    The different methods of preparation of superconducting wires have been discussed. The powder-in-tube technique is followed for the preparation of YBCO and BISCCO superconducting wires. The results are discussed. The present status of the industries in preparing the superconducting wires having the maximum J c values is discussed. (author). 30 refs., 6 figs., 2 tabs

  16. Pre-wired systems prove their worth.

    Science.gov (United States)

    2012-03-01

    The 'new generation' of modular wiring systems from Apex Wiring Solutions have been specified for two of the world's foremost teaching hospitals - the Royal London and St Bartholomew's Hospital, as part of a pounds sterling 1 billion redevelopment project, to cut electrical installation times, reduce on-site waste, and provide a pre-wired, factory-tested, power and lighting system. HEJ reports.

  17. 75 FR 4584 - Wire Decking From China

    Science.gov (United States)

    2010-01-28

    ... COMMISSION Wire Decking From China AGENCY: United States International Trade Commission. ACTION: Scheduling... retarded, by reason of subsidized and less-than-fair-value imports from China of wire decking, provided for..., producers, or exporters in China of wire decking, and that such ] products are being sold in the United...

  18. Development of instrumentation for fuel pin scanner

    International Nuclear Information System (INIS)

    Saisubalakshmi, D.; Parthasarathy, R.; Brahmaji Rao, J.S.; Senthilvadivu, E.; Seshadreesan, N.P.

    2011-01-01

    A study is being carried out using a surrogate vibro-packed fuel pin with micro-spheres of two different sizes to get the density distribution by gamma transmission technique. A shielded (with 2 mm slit of ∼ 2''SS collimator) LaBr scintillation detector is used as the detector system. A strong 137 Cs source is used as the source. The source strength as it is transmitted through the fuel pin is measured by the scintillation detector. The entire length of the fuel pin is gradually moved up from one end to other end and the detector is allowed to continuously examine the transmission profile of the fuel pin. The instrumentation for the fuel pin scanner has been developed and is integrated with the system. The instrumentation includes microcontroller based motor control system and customized detector pulse counting systems. The systems are interfaced to a computer through serial communication. (author)

  19. Compact beamforming in medical ultrasound scanners

    DEFF Research Database (Denmark)

    Tomov, Borislav Gueorguiev

    2003-01-01

    to fit a large number of channels on a single integrated circuit. The use of oversampled analog-to-digital (A/D) converters with the corresponding beamforming was identified as a particularly promising approach, since it provides both inexpensive and compact A/D conversion and allows for much more...... channels, and even more channels are necessary for 3-dimensional (3D) diagnostic imaging. On the other hand, there is a demand for inexpensive portable devices for use outside hospitals, in field conditions, where power consumption and compactness are important factors. The thesis starts...... quality is comparable to that of the very good scanners currently on the market. The performance results have been achieved with the use of a simple oversampled converter of second order. The use of a higher order oversampled converter will allow higher pulse frequency to be used while the high dynamic...

  20. A clinical molecular scanner: the Melanie project.

    Science.gov (United States)

    Hochstrasser, D F; Appel, R D; Vargas, R; Perrier, R; Vurlod, J F; Ravier, F; Pasquali, C; Funk, M; Pellegrini, C; Muller, A F

    1991-01-01

    We developed an expert system to analyze and interpret protein maps. This system, Melanie (medical electrophoresis analysis interactive expert), can distinguish between normal and cirrhotic liver and identify various types of cancer on the basis of protein patterns in biopsy specimens. Our findings suggest that some diseases associated with toxic compounds or modifications of the human genome can be diagnosed by expert systems that analyze protein maps. The combination of protein mapping and computer analysis could result in a clinically useful "molecular scanner". The massive amount of information analyzed and stored in such studies requires new strategies, including centralized databases and image transmission over networks. Increased understanding of protein expression and regulation will enhance the importance of the human genome project in medicine and biology.

  1. Experimental analysis of the velocity field in an anular channel with helicoidal wire

    International Nuclear Information System (INIS)

    Lemos, M.J.S. de.

    1979-06-01

    In general, nuclear reactor fuel elements are rod bundles with coolant flowing axially among them. LMFBR's (Liquid Metal Fast Breeder Reactor) have wire wrapped fuel rods, with the wire working as spacer and mixer. The present work consists in the experimental analysis of the velocity field created by a typical LMFBR fuel rod placed in a cylinder, yielding an annular channel with helicoidal wire. Using hot wire anemometry, the main and secondary velocity fields were measured. The range for Re was from 2.2x 10 4 to 6.1x 10 4 , for air. The aspect ratio, P/D, and the lead-to-diameter ratio, 1/D, were 1.2 and 15, respectively. (Author) [pt

  2. PePSS - A portable sky scanner for measuring extremely low night-sky brightness

    Science.gov (United States)

    Kocifaj, Miroslav; Kómar, Ladislav; Kundracik, František

    2018-05-01

    A new portable sky scanner designed for low-light-level detection at night is developed and employed in night sky brightness measurements in a rural region. The fast readout, adjustable sensitivity and linear response guaranteed in 5-6 orders of magnitude makes the device well suited for narrow-band photometry in both dark areas and bright urban and suburban environments. Quasi-monochromatic night-sky brightness data are advantageous in the accurate characterization of spectral power distribution of scattered and emitted light and, also allows for the possibility to retrieve light output patterns from whole-city light sources. The sky scanner can operate in both night and day regimes, taking advantage of the complementarity of both radiance data types. Due to its inherent very high sensitivity the photomultiplier tube could be used in night sky radiometry, while the spectrometer-equipped system component capable of detecting elevated intensities is used in daylight monitoring. Daylight is a source of information on atmospheric optical properties that in turn are necessary in processing night sky radiances. We believe that the sky scanner has the potential to revolutionize night-sky monitoring systems.

  3. A passive gamma scanner for estimation of plutonium in fabrication waste

    International Nuclear Information System (INIS)

    Venkatesan, P.P.; Burte, P.P.; Manohar, S.B.; Satya Prakash; Ramaniah, M.V.

    1978-01-01

    The solid plutonium wastes arising from plutonium handling laboratories and fuel fabrication facilities by their very nature (heterogeneous) are not amenable to proper sampling and hence to the standard techniques of estimation. For the proper accounting of nuclear materials a non-destructive method of waste assay is essential. A passive gamma-ray scanner developed in the Radiochemistry Division is described in the present report. The scanner detects the 384 KeV gamma complex of plutonium in a (3'' x 3'') NaI(Tl) detector. The rotation-collimation technique is used to achieve the flat response with respect to the plutonium distribution inside the waste can. The sensitivity of the scanner is 200 mg of Pu per can at 2 sigma level and 20% accuracy for a total scan time of 2000 sec. The assay results of typical waste cans and comparison of a few of these with chemical assay results are presented. This non-destructive method is fast, simple and has satisfactory accuracy. (author)

  4. Spectra of clinical CT scanners using a portable Compton spectrometer

    NARCIS (Netherlands)

    Duisterwinkel, Erik; van Abbema, J. K.; van Goethem, M. J.; Kawachimaru, R.; Paganini, Lucia; van der Graaf, E. R.; Brandenburg, Sijtze

    PURPOSE: Spectral information of the output of x-ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance. The purpose of this study is to design, validate,

  5. Radiation dosimetry of computed tomography x-ray scanners

    International Nuclear Information System (INIS)

    Poletti, J.L.; Williamson, B.D.P.; Le Heron, J.C.

    1983-01-01

    This report describes the development and application of the methods employed in National Radiation Laboratory (NRL) surveys of computed tomography x-ray scanners (CT scanners). It includes descriptions of the phantoms and equipment used, discussion of the various dose parameters measured, the principles of the various dosimetry systems employed and some indication of the doses to occupationally exposed personnel

  6. Verification of a CT scanner using a miniature step gauge

    DEFF Research Database (Denmark)

    Cantatore, Angela; Andreasen, J.L.; Carmignato, S.

    2011-01-01

    The work deals with performance verification of a CT scanner using a 42mm miniature replica step gauge developed for optical scanner verification. Errors quantification and optimization of CT system set-up in terms of resolution and measurement accuracy are fundamental for use of CT scanning...

  7. Vision Assisted Laser Scanner Navigation for Autonomous Robots

    DEFF Research Database (Denmark)

    Andersen, Jens Christian; Andersen, Nils Axel; Ravn, Ole

    2008-01-01

    This paper describes a navigation method based on road detection using both a laser scanner and a vision sensor. The method is to classify the surface in front of the robot into traversable segments (road) and obstacles using the laser scanner, this classifies the area just in front of the robot (2...

  8. Optical performance requirements for MEMS-scanner-based microdisplays

    Science.gov (United States)

    Urey, Hakan; Wine, David W.; Osborn, Thor D.

    2000-08-01

    High-resolution and high frame rate dynamic microdisplays can be implemented by scanning a photon beam in a raster format across the viewer's retina. Microvision is developing biaxial MEMS scanners for such video display applications. This paper discusses the optical performance requirements for scanning display systems. The display resolution directly translates into a scan-angle-mirror-size product and the frame rate translates into vertical and horizontal scanner frequencies. (theta) -product and fh are both very important figures of merit for scanner performance comparison. In addition, the static and dynamic flatness of the scanners, off-axis motion and scan repeatability, scanner position sensor accuracy all have a direct impact on display image quality.

  9. Clinical bending of nickel titanium wires

    Directory of Open Access Journals (Sweden)

    Stephen Chain

    2015-01-01

    Full Text Available Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our inventory but also customized the wire according to the treatment.

  10. Emittance growth due to Tevatron flying wires

    Energy Technology Data Exchange (ETDEWEB)

    Syphers, M; Eddy, Nathan

    2004-06-01

    During Tevatron injection, Flying Wires have been used to measure the transverse beam size after each transfer from the Main Injector in order to deduce the transverse emittances of the proton and antiproton beams. This amounts to 36 + 9 = 45 flies of each of 3 wire systems, with an individual wire passing through each beam bunch twice during a single ''fly''. below they estimate the emittance growth induced by the interaction of the wires with the particles during these measurements. Changes of emittance from Flying Wire measurements conducted during three recent stores are compared with the estimations.

  11. Proton radiography of intense-laser-irradiated wire-attached cone targets

    International Nuclear Information System (INIS)

    Yabuuchi, T.; Sawada, H.; Bartal, T.; Beg, F.N.; Batani, D.; Gizzi, L.A.; Key, M.H.; Mackinnon, A.J.; McLean, H.S.; Patel, P.K.; Norreys, P.A.; Spindloe, C.; Stephens, R.B.; Wei, M.S.; Theobald, W.

    2011-01-01

    Measurements of extreme electrostatic and magnetic fields are of interest for the study of high-energy-density plasmas. Results of proton deflectometry of cone-wire targets that are of interest to fast-ignition inertial confinement fusion are presented. (authors)

  12. Modifications in straight wire treatment.

    Science.gov (United States)

    Cardona, Alvin

    2010-01-01

    Orthodontic treatments have been modified with each new generation of clinicians. Today the emphasis is on facial esthetics and healthy temporomandibular joints. With orthopedic treatment, we can develop dental arches to get the necessary space to align the teeth and we can reach adequate function and esthetics, all within relatively good stability. By combining two-phase treatment with low friction fixed orthodontics and super elastic wires we produce light but continuous forces and we can provide better treatment than before. These types of forces cause physiological and functional orthopedic orthodontic reactions. The purpose of this article is to demonstrate our fixed orthopedic and orthodontic approach called "Modified Straight Wire" or "Physiologic Arch Technique." This technique is very successful with our patients because it can exert slow and continuous forces with minimal patient cooperation.

  13. Sintered wire cesium dispenser photocathode

    Science.gov (United States)

    Montgomery, Eric J; Ives, R. Lawrence; Falce, Louis R

    2014-03-04

    A photoelectric cathode has a work function lowering material such as cesium placed into an enclosure which couples a thermal energy from a heater to the work function lowering material. The enclosure directs the work function lowering material in vapor form through a low diffusion layer, through a free space layer, and through a uniform porosity layer, one side of which also forms a photoelectric cathode surface. The low diffusion layer may be formed from sintered powdered metal, such as tungsten, and the uniform porosity layer may be formed from wires which are sintered together to form pores between the wires which are continuous from the a back surface to a front surface which is also the photoelectric surface.

  14. Slice of LHC dipole wiring

    CERN Multimedia

    Dipole model slice made in 1994 by Ansaldo. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. 50’000 tonnes of steel sheets are used to make the magnet yokes that keep the wiring firmly in place. The yokes constitute approximately 80% of the accelerator's weight and, placed side by side, stretch over 20 km!

  15. Pin Wire Coating Trip Report

    International Nuclear Information System (INIS)

    Spellman, G P

    2004-01-01

    A meeting to discuss the current pin wire coating problems was held at the Reynolds plant in Los Angeles on 2MAR04. The attendance list for Reynolds personnel is attached. there was an initial presentation which gave a brief history and the current status of pin wire coating at Reynolds. There was a presentation by Lori Primus on the requirements and issues for the coating. There was a presentation by Jim Smith of LANL on the chemistry and to some extent process development done to date. There was a long session covering what steps should be taken in the short term and, to a lesser extent, the long term. The coating currently being used is a blend of two polymers, polyethersulfone and polyparabanic acid (PPA) and some TiO2 filler. This system was accepted and put into production when the pin wire coating was outsourced to another company in 1974. When that company no longer was interested, the wire coating was brought in-house to Reynolds. At that time polyparabanic acid was actually a commercial product available from Exxon under the trade name Tradlon. However, it appears that the material used at Reynolds was synthesized locally. Also, it appears that a single large batch was synthesized in that time period and used up to 1997 when the supply ran out. The reason for the inclusion of TiO2 is not known although it does act as a rheological thickener. However, a more controlled thickening can be obtained with materials such as fumed silica. This material would have less likelihood of causing point imperfections in the coatings. Also, the mixing technique being used for all stages of the process is a relatively low shear ball mill process and the author recommends a high shear process such as a three roll paint mill, at least for the final mixing. Since solvent is added to the powder at Reynolds, it may be that they need to have the paint mill there

  16. Wear of dragline wire ropes

    Energy Technology Data Exchange (ETDEWEB)

    Dayawansa, D.; Kuruppu, M.; Mashiri, F.; Bartosiewicz, H. [Monash University (Caulfield Campus), Caulfield East, Vic. (Australia). Department of Mechanical Engineering,

    2005-07-01

    Wire ropes are one of the most heavily used components in a dragline. Hoist ropes are subjected to fatigue due to the cyclic nature of load handling as well as due to rope bending over the sheaves and the drum under load. This leads to wire breaks due to fatigue. Accumulation of a number of wire breaks close to each other can have a detrimental effect on the rope. Furthermore, to allow for the increasing demand for higher load capacity coupled with the inconvenience of having very large ropes, the factor of safety is often compromised, which increases the wear rate. Drag ropes are also subjected to heavy loads. More importantly, they are allowed to drag along the rough mine surface subjecting them to external physical abrasion. This makes the life of drag ropes one of the lowest among those used in a dragline. Suspension and IBS ropes are relatively uniformly loaded during their regular usage although they need to withstand dynamic load cycles as well as bending. Hence they tend to last for a number of years on average. The paper analyses the wear types and their severity of each of these rope applications, and suggests methods to determine rope wear rates and the resulting rope life. The paper further gives suggestions for good operating and maintenance practice that can extend the rope life and help reduce the large expenditure associated with every major rope change in a dragline. 6 refs., 8 figs., 1 tab.

  17. Determining organ doses from computed tomography scanners using cadaveric subjects

    Science.gov (United States)

    Griglock, Thomas M.

    The use of computed tomographic (CT) imaging has increased greatly since its inception in 1972. Technological advances have increased both the applicability of CT exams for common health problems as well as the radiation doses used to perform these exams. The increased radiation exposures have garnered much attention in the media and government agencies, and have brought about numerous attempts to quantify the amount of radiation received by patients. While the overwhelming majority of these attempts have focused on creating models of the human body (physical or computational), this research project sought to directly measure the radiation inside an actual human being. Three female cadaveric subjects of varying sizes were used to represent live patients. Optically-stimulated luminescent (OSL) dosimeters were used to measure the radiation doses. A dosimeter placement system was developed, tested, and optimized to allow accurate and reproducible placement of the dosimeters within the cadaveric subjects. A broad-beam, 320-slice, volumetric CT scanner was utilized to perform all CT exams, including five torso exams, four cardiac exams, and three organ perfusion exams. Organ doses ranged in magnitude from less than 1 to over 120 mGy, with the largest doses measured for perfusion imaging. A methodology has been developed that allows fast and accurate measurement of actual organ doses resulting from CT exams. The measurements made with this methodology represent the first time CT organ doses have been directly measured within a human body. These measurements are of great importance because they allow comparison to the doses measured using previous methods, and can be used to more accurately assess the risks from CT imaging.

  18. Wire-line logging analysis of the 2007 JOGMEC/NRCan/Aurora Mallik gas hydrate production test well

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, T.; Takayama, T.; Nakamizu, M.; Yamamoto, K. [Japan Oil, Gas and Metals National Corp., Mihama-ku, Chiba (Japan); Dallimore, S.; Mwenifumbo, J.; Wright, F. [Natural Resources Canada, Sidney, BC (Canada). Geological Survey of Canada; Kurihara, M.; Sato, A. [Japan Oil Engineering Co., Chuo-ku, Tokyo (Japan); Al-Jubori, A. [Schlumberger Canada Ltd., Calgary, AB (Canada)

    2008-07-01

    Japan Oil, Gas and Metals National Corporation and Natural Resources Canada performed a full scale production test in the Mallik field, in Canada's Mackenzie Delta in April, 2007 in order to evaluate the productivity of methane hydrate (MH) by the depressurization method. The program involved an extensive wire-line logging program to evaluate reservoir properties; determine production/water injection intervals; evaluate cement bonding; and, interpret MH dissociation behavior throughout the production. The paper presented a review of the extensive wire-line logging program. It showed the role and workflow of wire-line logging applied in the production well. The well log evaluation for MH bearing zone was the primary focus of the paper. The paper discussed the objectives of the program as well as tools used as part of the study, including several new open hole wire-line logging tools such as magnetic resonance scanner, Rt Scanner, sonic scanner, as well as other advanced logging tools used to obtain data on the occurrence of MH, lithology, MH pore saturation, porosity and permeability. Perforation intervals of the production and water injection zones were selected using a multidisciplinary approach. Candidate test intervals considering lithology, MH pore saturation, initial effective permeability and absolute permeability were identified based on the results of geological interpretation and open hole logging analysis. Reservoir layer models were built to allow for reservoir numerical simulations for several perforation scenarios. Using the results of well log analysis, reservoir numerical simulation, and consideration of operational constraints, a MH bearing formation from 1093 to 1105 mKB was selected for 2007 testing. Three zones were selected for injection of produced water. It was concluded that at the perforation interval of the MH bearing formation (1093-1105 mKB) a selective dissociation was observed in the lateral direction. 20 refs., 3 tabs., 9 figs.

  19. Focal plane scanner with reciprocating spatial window

    Science.gov (United States)

    Mao, Chengye (Inventor)

    2000-01-01

    A focal plane scanner having a front objective lens, a spatial window for selectively passing a portion of the image therethrough, and a CCD array for receiving the passed portion of the image. All embodiments have a common feature whereby the spatial window and CCD array are mounted for simultaneous relative reciprocating movement with respect to the front objective lens, and the spatial window is mounted within the focal plane of the front objective. In a first embodiment, the spatial window is a slit and the CCD array is one-dimensional, and successive rows of the image in the focal plane of the front objective lens are passed to the CCD array by an image relay lens interposed between the slit and the CCD array. In a second embodiment, the spatial window is a slit, the CCD array is two-dimensional, and a prism-grating-prism optical spectrometer is interposed between the slit and the CCD array so as to cause the scanned row to be split into a plurality of spectral separations onto the CCD array. In a third embodiment, the CCD array is two-dimensional and the spatial window is a rectangular linear variable filter (LVF) window, so as to cause the scanned rows impinging on the LVF to be bandpass filtered into spectral components onto the CCD array through an image relay lens interposed between the LVF and the CCD array.

  20. Whole-body 35-GHz security scanner

    Science.gov (United States)

    Appleby, Roger; Anderton, Rupert N.; Price, Sean; Sinclair, Gordon N.; Coward, Peter R.

    2004-08-01

    A 35GHz imager designed for Security Scanning has been previously demonstrated. That imager was based on a folded conical scan technology and was constructed from low cost materials such as expanded polystyrene and printed circuit board. In conjunction with an illumination chamber it was used to collect indoor imagery of people with weapons and contraband hidden under their clothing. That imager had a spot size of 20mm and covered a field of view of 20 x 10 degrees that partially covered the body of an adult from knees to shoulders. A new variant of this imager has been designed and constructed. It has a field of view of 36 x 18 degrees and is capable of covering the whole body of an adult. This was achieved by increasing the number of direct detection receivers from the 32 used in the previous design to 58, and by implementing an improved optical design. The optics consist of a front grid, a polarisation device which converts linear to circular polarisation and a rotating scanner. This new design uses high-density expanded polystyrene as a correcting element on the back of the front grid. This gives an added degree of freedom that allows the optical design to be diffraction limited over a very wide field of view. Obscuration by the receivers and associated components is minimised by integrating the post detection electronics at the receiver array.

  1. From Beamline to Scanner with 225Ac

    Science.gov (United States)

    Robertson, Andrew K. H.; Ramogida, Caterina F.; Kunz, Peter; Rodriguez-Rodriguez, Cristina; Schaffer, Paul; Sossi, Vesna

    2016-09-01

    Due to the high linear energy transfer and short range of alpha-radiation, targeted radiation therapy using alpha-emitting pharmaceuticals that successfully target small disease clusters will kill target cells with limited harm to healthy tissue, potentially treating the most aggressive forms of cancer. As the parent of a decay chain with four alpha- and two beta-decays, 225Ac is a promising candidate for such a treatment. However, this requires retention of the entire decay chain at the target site, preventing the creation of freely circulating alpha-emitters that reduce therapeutic effect and increase toxicity to non-target tissues. Two major challenges to 225Ac pharmaceutical development exist: insufficient global supply, and the difficulty of preventing toxicity by retaining the entire decay chain at the target site. While TRIUMF works towards large-scale (C i amounts) production of 225Ac, we already use our Isotope Separation On-Line facility to provide small (< 1 mCi) quantities for in-house chemistry and imaging research that aims to improve and assess 225Ac radiopharmaceutical targeting. This presentation provides an overview of this research program and the journey of 225Ac from the beamline to the scanner. This research is funded by the Natural Sciences and Engineering Research Council of Canada.

  2. Point Cloud Analysis for Uav-Borne Laser Scanning with Horizontally and Vertically Oriented Line Scanners - Concept and First Results

    Science.gov (United States)

    Weinmann, M.; Müller, M. S.; Hillemann, M.; Reydel, N.; Hinz, S.; Jutzi, B.

    2017-08-01

    In this paper, we focus on UAV-borne laser scanning with the objective of densely sampling object surfaces in the local surrounding of the UAV. In this regard, using a line scanner which scans along the vertical direction and perpendicular to the flight direction results in a point cloud with low point density if the UAV moves fast. Using a line scanner which scans along the horizontal direction only delivers data corresponding to the altitude of the UAV and thus a low scene coverage. For these reasons, we present a concept and a system for UAV-borne laser scanning using multiple line scanners. Our system consists of a quadcopter equipped with horizontally and vertically oriented line scanners. We demonstrate the capabilities of our system by presenting first results obtained for a flight within an outdoor scene. Thereby, we use a downsampling of the original point cloud and different neighborhood types to extract fundamental geometric features which in turn can be used for scene interpretation with respect to linear, planar or volumetric structures.

  3. Precipitation formation in recrystallized nickel-plated non-sag tungsten wire

    International Nuclear Information System (INIS)

    Lai, Z.H.

    1994-01-01

    It is well established that some metals, such as palladium and nickel, can easily penetrate into tungsten by fast diffusion via crystal defects such as grain boundaries and dislocations. As a result of the fast penetration of these so called activators the recrystallization temperature of heavily drawn non-sag tungsten wire can be lower from about 2,000 C to about 1,000 C, thus the application of the tungsten wire, serving as reinforcement material in metal matrix composites used at high temperatures, is limited. An interesting question is in which form these activators exist in the recrystallized tungsten wire. It is generally believed that W-Ni intermediate compounds could form in the recrystallized material, presumably at grain boundaries. The free energy difference between the pure tungsten fibbers and the precipitating W(Ni) solid solution was suggested as the chemical driving force which governed the recrystallization process. The presence of nickel in small particles had also been observed in recrystallized grains of nickel plated tungsten wires using scanning electron microscopy (SEM) and secondary ion mass spectroscopy. These particles were considered to be nickel rich precipitates. However, a detailed investigation of the precipitation process has not been reported. In the present work an investigation of the structure, composition and distribution of nickel rich particles precipitated in recrystallized grains of nickel plated heavily drawn non-sage tungsten wires was carried out using analytical electron microscopy (AEM)

  4. A Vibrating Wire System For Quadrupole Fiducialization

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Zachary

    2010-12-13

    A vibrating wire system is being developed to fiducialize the quadrupoles between undulator segments in the LCLS. This note provides a detailed analysis of the system. The LCLS will have quadrupoles between the undulator segments to keep the electron beam focused. If the quadrupoles are not centered on the beam axis, the beam will receive transverse kicks, causing it to deviate from the undulator axis. Beam based alignment will be used to move the quadrupoles onto a straight line, but an initial, conventional alignment must place the quadrupole centers on a straight line to 100 {micro}m. In the fiducialization step of the initial alignment, the position of the center of the quadrupole is measured relative to tooling balls on the outside of the quadrupole. The alignment crews then use the tooling balls to place the magnet in the tunnel. The required error on the location of the quadrupole center relative to the tooling balls must be less than 25 {micro}m. In this note, we analyze a system under construction for the quadrupole fiducialization. The system uses the vibrating wire technique to position a wire onto the quadrupole magnetic axis. The wire position is then related to tooling balls using wire position detectors. The tooling balls on the wire position detectors are finally related to tooling balls on the quadrupole to perform the fiducialization. The total 25 {micro}m fiducialization error must be divided between these three steps. The wire must be positioned onto the quadrupole magnetic axis to within 10 {micro}m, the wire position must be measured relative to tooling balls on the wire position detectors to within 15 {micro}m, and tooling balls on the wire position detectors must be related to tooling balls on the quadrupole to within 10 {micro}m. The techniques used in these three steps will be discussed. The note begins by discussing various quadrupole fiducialization techniques used in the past and discusses why the vibrating wire technique is our method

  5. Electro-mechanics of drift tube wires

    International Nuclear Information System (INIS)

    Milburn, R.H.

    1997-01-01

    The position and stability of the sense wires in very long drift tubes are affected by both gravitational and electrostatic forces, as well as by the wire tension. For a tube to be used as an element of a high-resolution detector all these forces and their effects must be understood in appropriately precise detail. In addition, the quality control procedures applied during manufacture and detector installation must be adequate to ensure that the internal wire positions remain within tolerances. It may be instructive to practitioners to review the simple theory of a taut wire in the presence of anisotropic gravitational and electrostatic fields to illustrate the conditions for stability, the equilibrium wire displacement from straightness, and the effect of the fields on the mechanical vibration frequencies. These last may be used to monitor the wire configuration externally. A number of practical formulae result and these are applied to illustrative examples. (orig.)

  6. Electromagnetic Behaviour of Metallic Wire Structures

    CERN Document Server

    Chui, S T

    2013-01-01

    Despite the recent development and interest in the photonics of metallic wire structures, the relatively simple concepts and physics often remain obscured or poorly explained to those who do not specialize in the field. Electromagnetic Behaviour of Metallic Wire Structures provides a clear and coherent guide to understanding these phenomena without excessive numerical calculations.   Including both background material and detailed derivations of the various different formulae applied, Electromagnetic Behaviour of Metallic Wire Structures describes how to extend basic circuit theory relating to voltages, currents, and resistances of metallic wire networks to include situations where the currents are no longer spatially uniform along the wire. This lays a foundation for a deeper understanding of the many new phenomena observed in meta-electromagnetic materials.   Examples of applications are included to support this new approach making Electromagnetic Behaviour of Metallic Wire Structures a comprehensive and ...

  7. Phosphorus in antique iron music wire.

    Science.gov (United States)

    Goodway, M

    1987-05-22

    Harpsichords and other wire-strung musical instruments were made with longer strings about the beginning of the 17th century. This change required stronger music wire. Although these changes coincided with the introduction of the first mass-produced steel (iron alloyed with carbon), carbon was not found in samples of antique iron harpsichord wire. The wire contained an amount of phosphorus sufficient to have impeded its conversion to steel, and may have been drawn from iron rejected for this purpose. The method used to select pig iron for wire drawing ensured the highest possible phosphorus content at a time when its presence in iron was unsuspected. Phosphorus as an alloying element has had the reputation for making steel brittle when worked cold. Nevertheless, in replicating the antique wire, it was found that lowcarbon iron that contained 0.16 percent phosphorus was easily drawn to appropriate gauges and strengths for restringing antique harpsichords.

  8. Explosion symmetry improvement of polyimide-coated tungsten wire in vacuum on negative discharge facility

    Science.gov (United States)

    Li, Mo; Wu, Jian; Lu, Yihan; Li, Xingwen; Li, Yang; Qiu, Mengtong

    2018-01-01

    Tungsten wire explosion is very asymmetric when fast current rate and insulated coatings are both applied on negative discharge facility using a 24-mm-diameter cathode geometry, which is commonly used on mega-ampere facilities. It is inferred, based on an analytical treatment of the guiding center drift and COMSOL simulations, that the large negative radial electric field causes early voltage breakdown and terminates energy deposition into the wire core on the anode side of the wire. After the anode side is short circuited, the radial electric field along the wire surface on the cathode side will change its polarity and thus leading to additional energy deposition into the wire core. This change causes ˜10 times larger energy deposition and ˜14 times faster explosion velocity in the cathode side than the anode side. In order to reduce this asymmetry, a hollow cylindrical cathode geometry was used to reverse the polarity of radial electric field and was optimized to use on multi-MA facilities. In this case, fully vaporized polyimide-coated tungsten wire with great symmetry improvement was achieved with energy deposition of ˜8.8 eV/atom. The atomic and electronic density distributions for the two different load geometries were obtained by the double-wavelength measurement.

  9. A stationary digital breast tomosynthesis scanner

    Science.gov (United States)

    Qian, Xin; Tucker, Andrew; Gidcumb, Emily; Lu, Jianping; Zhou, Otto; Spronk, Derrek; Sprenger, Frank; Zhang, Yiheng; Kennedy, Don; Farbizio, Tom; Jing, Zhenxue

    2012-03-01

    A prototype stationary digital breast tomosynthesis (s-DBT) system has been developed by retrofitting a Hologic Selenia Dimension rotating gantry tomosynthesis scanner with a spatially distributed carbon nanotube (CNT) x-ray source array. The goal is to improve the system spatial resolution by removing the x-ray tube motion induced focal spot blurring. The CNT x-ray source array comprises 31 individually addressable x-ray beams covering 30° angular span. Each x-ray beam has a minimum focal spot size of 0.64×0.61mm (full-width-at-half-maximum), a stationary W anode operating up to 50kVp, and 1mm thick Al filter. The flux from each beam is regulated and varied using dedicated control electronics. The maximum tube current is determined by the heat load of the stationary anode and depends on the energy, pulse width and the focal spot size used. Stable operation at 28kVp, 27mA tube current, 250msec pulse width and 38mA tube current, 183msec pulse width per exposure was achieved with extended lifetime. The standard ACR phantom was imaged and analyzed to evaluate the image quality. The actual scanning speed depends on the number of views and the readout time of the x-ray detector. With the present detector, 6 second scanning time at either 15 views or 31 views can be achieved at 100mAs total imaging dose with a detector readout time of 240msec.

  10. NOAA-9 Earth Radiation Budget Experiment (ERBE) scanner offsets determination

    Science.gov (United States)

    Avis, Lee M.; Paden, Jack; Lee, Robert B., III; Pandey, Dhirendra K.; Stassi, Joseph C.; Wilson, Robert S.; Tolson, Carol J.; Bolden, William C.

    1994-01-01

    The Earth Radiation Budget Experiment (ERBE) instruments are designed to measure the components of the radiative exchange between the Sun, Earth and space. ERBE is comprised of three spacecraft, each carrying a nearly identical set of radiometers: a three-channel narrow-field-of-view scanner, a two-channel wide-field-of-view (limb-to-limb) non-scanning radiometer, a two-channel medium field-of view (1000 km) non-scanning radiometer, and a solar monitor. Ground testing showed the scanners to be susceptible to self-generated and externally generated electromagnetic noise. This paper describes the pre-launch corrective measures taken and the post-launch corrections to the NOAA-9 scanner data. The NOAA-9 scanner has met the mission objectives in accuracy and precision, in part because of the pre-launch reductions of and post-launch data corrections for the electromagnetic noise.

  11. Landsat 1-5 Multispectral Scanner V1

    Data.gov (United States)

    National Aeronautics and Space Administration — Abstract: The Landsat Multispectral Scanner (MSS) was a sensor onboard Landsats 1 through 5 and acquired images of the Earth nearly continuously from July 1972 to...

  12. Dental models made with an intraoral scanner: A validation study.

    NARCIS (Netherlands)

    Cuperus, A.M.; Harms, M.C.; Rangel, F.A.; Bronkhorst, E.M.; Schols, J.G.J.H.; Breuning, K.H.

    2012-01-01

    INTRODUCTION: Our objectives were to determine the validity and reproducibility of measurements on stereolithographic models and 3-dimensional digital dental models made with an intraoral scanner. METHODS: Ten dry human skulls were scanned; from the scans, stereolithographic models and digital

  13. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  14. IEE wiring regulations explained and illustrated

    CERN Document Server

    Scaddan, Brian

    2013-01-01

    The IEE Wiring Regulations Explained and Illustrated, Second Edition discusses the recommendations of the IEE Regulations for the Electrical Equipment of Buildings for the safe selection or erection of wiring installations. The book emphasizes earthing, bonding, protection, and circuit design of electrical wirings. The text reviews the fundamental requirements for safety, earthing systems, the earth fault loop impedance, and supplementary bonding. The book also describes the different types of protection, such as protection against mechanical damage, overcurrent, under voltage (which prevents

  15. Spectra of clinical CT scanners using a portable Compton spectrometer

    International Nuclear Information System (INIS)

    Duisterwinkel, H. A.; Abbema, J. K. van; Kawachimaru, R.; Paganini, L.; Graaf, E. R. van der; Brandenburg, S.; Goethem, M. J. van

    2015-01-01

    Purpose: Spectral information of the output of x-ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance. The purpose of this study is to design, validate, and apply a compact portable Compton spectrometer that was constructed to accurately measure x-ray spectra of CT scanners. Methods: In the design of the Compton spectrometer, the shielding materials were carefully chosen and positioned to reduce background by x-ray fluorescence from the materials used. The spectrum of Compton scattered x-rays alters from the original source spectrum due to various physical processes. Reconstruction of the original x-ray spectrum from the Compton scattered spectrum is based on Monte Carlo simulations of the processes involved. This reconstruction is validated by comparing directly and indirectly measured spectra of a mobile x-ray tube. The Compton spectrometer is assessed in a clinical setting by measuring x-ray spectra at various tube voltages of three different medical CT scanner x-ray tubes. Results: The directly and indirectly measured spectra are in good agreement (their ratio being 0.99) thereby validating the reconstruction method. The measured spectra of the medical CT scanners are consistent with theoretical spectra and spectra obtained from the x-ray tube manufacturer. Conclusions: A Compton spectrometer has been successfully designed, constructed, validated, and applied in the measurement of x-ray spectra of CT scanners. These measurements show that our compact Compton spectrometer can be rapidly set-up using the alignment lasers of the CT scanner, thereby enabling its use in commissioning, troubleshooting, and, e.g., annual performance check-ups of CT scanners

  16. Spectra of clinical CT scanners using a portable Compton spectrometer.

    Science.gov (United States)

    Duisterwinkel, H A; van Abbema, J K; van Goethem, M J; Kawachimaru, R; Paganini, L; van der Graaf, E R; Brandenburg, S

    2015-04-01

    Spectral information of the output of x-ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance. The purpose of this study is to design, validate, and apply a compact portable Compton spectrometer that was constructed to accurately measure x-ray spectra of CT scanners. In the design of the Compton spectrometer, the shielding materials were carefully chosen and positioned to reduce background by x-ray fluorescence from the materials used. The spectrum of Compton scattered x-rays alters from the original source spectrum due to various physical processes. Reconstruction of the original x-ray spectrum from the Compton scattered spectrum is based on Monte Carlo simulations of the processes involved. This reconstruction is validated by comparing directly and indirectly measured spectra of a mobile x-ray tube. The Compton spectrometer is assessed in a clinical setting by measuring x-ray spectra at various tube voltages of three different medical CT scanner x-ray tubes. The directly and indirectly measured spectra are in good agreement (their ratio being 0.99) thereby validating the reconstruction method. The measured spectra of the medical CT scanners are consistent with theoretical spectra and spectra obtained from the x-ray tube manufacturer. A Compton spectrometer has been successfully designed, constructed, validated, and applied in the measurement of x-ray spectra of CT scanners. These measurements show that our compact Compton spectrometer can be rapidly set-up using the alignment lasers of the CT scanner, thereby enabling its use in commissioning, troubleshooting, and, e.g., annual performance check-ups of CT scanners.

  17. Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL)

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose:The Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL) provides a variety of research, design engineering and prototype fabrication services...

  18. The Wire Flyer Towed Profiling System

    Science.gov (United States)

    Roman, C.; Ullman, D. S.; Hebert, D.

    2016-02-01

    The Wire Flyer is an autonomous profiling vehicle that slides up and down a standard towed cable in a controlled manner using the lift created by wing foils. The vehicle is able to create high resolution water-column sections within a specified depth band in an automated manner. The Wire Flyer is different than standard undulating tow bodies in that it decouples the vehicle's motion from the tow cable dynamics. Due to this separation the vehicle is able to profile with nearly 1:1 horizontal to vertical motion. A heavy depressor weight is fixed to the end of the cable and the cable shape remains relatively static during operation. The vehicle uses a closed loop wing angle controller to achieve desired vertical velocities between 0 and 2.5 m/s for ship speeds between 1.5 and 2.5 m/s. During typical operations, updated commands and condensed data samples can be sent to and from the vehicle via an acoustic modem to adjust the profiling pattern to ensure the desired coverage. The current 1000 meter rated vehicle is equipped with a SBE 49 FastCAT CTD, and can carry additional sensors for oxygen, Chlorophyll fluorescence and acoustic echosounding. Results showing the vehicle performance as well as the quality of the processed CTD data will be presented from three test cruises to the New England Shelf Break Front. Many shallow and deep sections were obtained with horizontal resolution that is not otherwise achievable with undulating tow bodies, underway CTDs, standard CTD tow-yos, gliders or free swimming AUVs. A typical survey at ship speeds of 3-4 knots can profile over a depth band between 200 and 600 meters depth with a repeat cycle length of less than 1 km. The vehicle concept is depth independent and could work with a full ocean depth design. Application areas for the system include sub-meso scale observations of fronts, vent and seep plumes, oxygen minimum layers, mixing and mid-water bioacoustics.

  19. FE modeling of Cu wire bond process and reliability

    NARCIS (Netherlands)

    Yuan, C.A.; Weltevreden, E.R.; Akker, P. van den; Kregting, R.; Vreugd, J. de; Zhang, G.Q.

    2011-01-01

    Copper based wire bonding technology is widely accepted by electronic packaging industry due to the world-wide cost reduction actions (compared to gold wire bond). However, the mechanical characterization of copper wire differs from the gold wire; hence the new wire bond process setting and new bond

  20. 47 CFR 76.804 - Disposition of home run wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Disposition of home run wiring. 76.804 Section... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.804 Disposition of home run wiring. (a) Building-by-building disposition of home run wiring. (1) Where an MVPD owns the home run wiring in an MDU...

  1. Utilization pattern of whole body computed tomography scanner

    International Nuclear Information System (INIS)

    Youn, Chul Ho; Lee, Sang Suk

    1986-01-01

    Computed tomography scanner (CT scanner) is one of the most expensive and sophisticated diagnostic tool and has already been utilized in many hospitals in Korea. The price as well as operating costs of CT scanner is so expensive as to regulate its installment by government even in the United States. In order to identify the efficient utilization of the CT scanner, the utilization pattern for CT scanning was analyzed at three general hospital in seoul. The results are as follows: 1. Five out of one thousand outpatients and five out of one hundred inpatients were CT scanned. 2. Eighty percent of patients who were scanned were those of inpatients of the hospitals where the scanned are installed. 3. Head standings constitute 45.6 percent of examinations, internal medicine 63.8 percent, and 38.5 percent neurosurgery respectively. 4. The rate of indication for CT scanning showed no statistically significant difference between insured and non-insured groups. 5. Computed tomography scanner units were operated 5.5 days a week in average and full operation rate was 79.5% in average. 6. The major diagnoses mode by head scanning were: hematoma (56.7%), infarction (12.6%), tumor (8.2%), and hydrocephalus (4.4%). 7. Number of patients taken CT Scanning was 43 persons a week in average for each whole body scanner unit

  2. Intra-wire resistance and AC loss in multi-filamentary MgB2 wires

    NARCIS (Netherlands)

    Zhou, Chao; Offringa, Wietse; Bergen, Anne-Henriette; Wessel, Wilhelm A.J.; Krooshoop, Hendrikus J.G.; Dhalle, Marc M.J.; Sumption, M.D.; Collings, E.W.; Rindfleisch, M.; Tomsic, M.; ten Kate, Herman H.J.; Nijhuis, Arend

    2013-01-01

    Intra-wire resistance and AC loss of various multi-filamentary MgB2 wires with filaments surrounded by Nb barriers have been measured and analyzed. The intra-wire resistance is measured with a direct four-probe voltage–current method at various temperatures. The AC loss is acquired by both vibrating

  3. THERMO-MECHANICALLY PROCESSED ROLLED WIRE FOR HIGH-STRENGTH ON-BOARD WIRE

    Directory of Open Access Journals (Sweden)

    V. A. Lutsenko

    2011-01-01

    Full Text Available It is shown that at twisting of wire of diameter 1,83 mm, produced by direct wire drawing of thermomechanically processed rolled wire of diameter 5,5 mm of steel 90, metal stratification is completely eliminated at decrease of carbon, manganese and an additional alloying of chrome.

  4. Thermal Recovery from Cold-Working in Type K Bare-Wire Thermocouples

    Science.gov (United States)

    Greenen, A. D.; Webster, E. S.

    2017-12-01

    Cold-working of most thermocouples has a significant, direct impact on the Seebeck coefficient which can lead to regions of thermoelectric inhomogeneity and accelerated drift. Cold-working can occur during the wire swaging process, when winding the wire onto a bobbin, or during handling by the end user—either accidentally or deliberately. Swaging-induced cold-work in thermocouples, if uniformly applied, may result in a high level of homogeneity. However, on exposure to elevated temperatures, the subsequent recovery process from the cold-working can then result in significant drift, and this can in turn lead to erroneous temperature measurements, often in excess of the specified manufacturer tolerances. Several studies have investigated the effects of cold-work in Type K thermocouples usually by bending, or swaging. However, the amount of cold-work applied to the thermocouple is often difficult to quantify, as the mechanisms for applying the strains are typically nonlinear when applied in this fashion. A repeatable level of cold-working is applied to the different wires using a tensional loading apparatus to apply a known yield displacement to the thermoelements. The effects of thermal recovery from cold-working can then be accurately quantified as a function of temperature, using a linear gradient furnace and a high-resolution homogeneity scanner. Variation in these effects due to differing alloy compositions in Type K wire is also explored, which is obtained by sourcing wire from a selection of manufacturers. The information gathered in this way will inform users of Type K thermocouples about the potential consequences of varying levels of cold-working and its impact on the Seebeck coefficient at a range of temperatures between ˜ 70°C and 600° C. This study will also guide users on the temperatures required to rapidly alleviate the effects of cold-working using thermal annealing treatments.

  5. Recent advances in theoretical and numerical studies of wire array Z-pinch in the IAPCM

    Science.gov (United States)

    Ding, Ning; Zhang, Yang; Xiao, Delong; Wu, Jiming; Huang, Jun; Yin, Li; Sun, Shunkai; Xue, Chuang; Dai, Zihuan; Ning, Cheng; Shu, Xiaojian; Wang, Jianguo; Li, Hua

    2014-12-01

    Fast Z-pinch has produced the most powerful X-ray radiation source in laboratory and also shows the possibility to drive inertial confinement fusion (ICF). Recent advances in wire-array Z-pinch researches at the Institute of Applied Physics and Computational Mathematics are presented in this paper. A typical wire array Z-pinch process has three phases: wire plasma formation and ablation, implosion and the MRT instability development, stagnation and radiation. A mass injection model with azimuthal modulation coefficient is used to describe the wire initiation, and the dynamics of ablated plasmas of wire-array Z-pinches in (r, θ) geometry is numerically studied. In the implosion phase, a two-dimensional(r, z) three temperature radiation MHD code MARED has been developed to investigate the development of the Magneto-Rayleigh-Taylor(MRT) instability. We also analyze the implosion modes of nested wire-array and find that the inner wire-array is hardly affected before the impaction of the outer wire-array. While the plasma accelerated to high speed in the implosion stage stagnates on the axis, abundant x-ray radiation is produced. The energy spectrum of the radiation and the production mechanism are investigated. The computational x-ray pulse shows a reasonable agreement with the experimental result. We also suggest that using alloyed wire-arrays can increase multi-keV K-shell yield by decreasing the opacity of K-shell lines. In addition, we use a detailed circuit model to study the energy coupling between the generator and the Z-pinch implosion. Recently, we are concentrating on the problems of Z-pinch driven ICF, such as dynamic hohlraum and capsule implosions. Our numerical investigations on the interaction of wire-array Z-pinches on foam convertors show qualitative agreements with experimental results on the "Qiangguang I" facility. An integrated two-dimensional simulation of dynamic hohlraum driven capsule implosion provides us the physical insights of wire

  6. Long-Wearing Wire Guide For Welding Torch

    Science.gov (United States)

    Gutow, David A.; Burley, Richard K.; Gilbert, Jeffrey L.; Fogel, Irving

    1992-01-01

    Insert for wire-guide tube on tungsten/inert-gas welding apparatus extends life of guide tube and increases accuracy of weld. Hardened insert resists wear by sliding tungsten wire. Chamfer guides wire into insert.

  7. 29 CFR 1919.79 - Wire rope.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Wire rope. 1919.79 Section 1919.79 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED... recommended by the equipment or the wire rope manufacturer due to actual working condition requirements. In...

  8. Wire compensation: Performance, SPS MDs, pulsed system

    CERN Document Server

    Dorda, U

    2008-01-01

    A wire compensation (BBLR) scheme has been proposed in order to improve the long range beam-beam performance of the nominal LHC and its phase 1 and phase 2 upgrades[1]. In this paper we present experimental experience of the CERN SPS wires (BBLR) and report on progress with the RF BBLR.

  9. WIRED magazine announces rave awards nominees

    CERN Multimedia

    2002-01-01

    WIRED Magazine has anounced the nominees for its fourth annual WIRED Rave Awards, celebrating innovation and the individuals transforming commerce and culture. Jeffrey Hangst of the University of Aarhus has been nominated in the science category, for his work on the ATHENA Experiment, CERN (1/2 page).

  10. Kirschner Wire Breakage during Removal Requiring Retrieval

    Directory of Open Access Journals (Sweden)

    Kai Yuen Wong

    2016-01-01

    Full Text Available Kirschner wires (K-wires are widely used for fixation of fractures and dislocations in the hand as they are readily available, reliable, and cost-effective. Complication rates of up to 18% have been reported. However, K-wire breakage during removal is rare. We present one such case illustrating a simple technique for retrieval. A 35-year-old male presented with a distal phalanx fracture of his right middle finger. This open fracture was treated with K-wire fixation. Postoperatively, he developed a pin site infection with associated finger swelling. The K-wire broke during removal with the proximal piece completely retained in his middle phalanx. To minimise risk of osteomyelitis, the K-wire was removed with a novel surgical technique. He had full return of hand function. Intraoperative K-wire breakage has a reported rate of 0.1%. In our case, there was no obvious cause of breakage and the patient denied postoperative trauma. On the other hand, pin site infections are much more common with reported rates of up to 7% in the hand or wrist. K-wire fixation is a simple method for bony stabilisation but can be a demanding procedure with complications often overlooked. It is important to be aware of the potential sequelae.

  11. Hot-wire anemometer for spirography.

    Science.gov (United States)

    Plakk, P; Liik, P; Kingisepp, P H

    1998-01-01

    The use of a constant temperature hot-wire anemometer flow sensor for spirography is reported. The construction, operating principles and calibration procedure of the apparatus are described, and temperature compensation method is discussed. Frequency response is studied. It is shown that this hot-wire flow transducer satisfies common demands with respect to accuracy, response time and temperature variations.

  12. Quality assurance for MR stereotactic imaging for three Siemens scanners

    International Nuclear Information System (INIS)

    Kozubikova, P.; Novotny, J. Jr.; Kulhova, K.; Mihalova, P.; Tamasova, J.; Veselsk, T.

    2014-01-01

    Quality assurance of stereotactic imaging, especially with MRI (magnetic resonance imaging), is a complex issue. It can be divided in the basic verification and commissioning of a particular new scanner or a new scanning MRI protocol that is being implemented into a clinical practice and the routine quality assurance performed for each single radiosurgical case. The aim of this study was geometric distortion assessment in MRI with a special PTGR (Physikalisch-Technische Gesellschaft fuer Radiologie - GmbH, Tuebingen, Germany) target phantom. PTGR phantom consists of 21 three-dimensional cross-hairs filled with contrast medium. Cross hairs are positioned at known Leksell coordinates with a precision of better than 0.1 mm and covering the whole stereotactic space. The phantom can be fixed in the Leksell stereotactic frame and thus stereotactic imaging procedures can be reproduced following exactly the same steps as for a real patient, including also the stereotactic image definition in the Leksell GammaPlan. Since the geometric position (stereotactic coordinates) of each cross-hair is known based on the construction of the phantom, it can be compared with the actual measured Leksell coordinates based on the stereotactic MRI. Deviations between expected and actual coordinates provide information about the level of distortion. The measured distortions proved satisfactory accuracy precision for stereotactic localization at 1.5 T Siemens Magnetom Avanto scanner, Siemens Magnetom Symphony scanner and 3T Siemens Magnetom Skyra scanner (Na Homolce Hospital, Prague). The mean distortion for these MR scanners for standard imaging protocol (T1 weighted 3D images) were 0.8 mm, 1.1 mm and 1.1 mm and maximum distortions were 1.3 mm, 1.9 mm and 2.2 mm, respectively.There was detected dependence of the distortions on the slice orientation and the type of imaging protocol. Image distortions are also property of each particular scanner, the worst distortion were observed for 3T

  13. Fast spiral-scan atomic force microscopy

    International Nuclear Information System (INIS)

    Mahmood, I A; Reza Moheimani, S O

    2009-01-01

    In this paper, we describe a new scanning technique for fast atomic force microscopy. In this method, the sample is scanned in a spiral pattern instead of the well established raster pattern. A spiral scan can be produced by applying single frequency cosine and sine signals with slowly varying amplitudes to the x-axis and y-axis of an atomic force microscope (AFM) scanner respectively. The use of the single tone input signals allows the scanner to move at high speeds without exciting the mechanical resonance of the device and with relatively small control efforts. Experimental results obtained by implementing this technique on a commercial AFM indicate that high-quality images can be generated at scan frequencies well beyond the raster scans.

  14. Guide Wire Entrapment during Central Venous Catheterization

    Directory of Open Access Journals (Sweden)

    Kyung Woo Kim

    2014-05-01

    Full Text Available We experienced a case of venous vessel wall entrapment between the introducer needle and the guide wire during an attempt to perform right internal jugular vein (IJV catheterization. The guide wire was introduced with no resistance but could not be withdrawn. We performed ultrasonography and C-arm fluoroscopy to confirm the entrapment location. We assumed the introducer needle penetrated the posterior vessel wall during the puncture and that only the guide wire entered the vein; an attempt to retract the wire pinched the vein wall between the needle tip and the guide wire. Careful examination with various diagnostic tools to determine the exact cause of entrapment is crucial for reducing catastrophic complications and achieving better outcomes during catheterization procedures.

  15. Fossilized bioelectric wire - the trace fossilTrichichnus.

    Science.gov (United States)

    Kędzierski, M; Uchman, A; Sawlowicz, Z; Briguglio, A

    2015-04-16

    The trace fossil Trichichnus is proposed as an indicator of fossil bioelectric bacterial activity at the oxic-anoxic interface zone of marine sediments. This fulfils the idea that such processes, commonly found in the modern realm, should be also present in the geological past. Trichichnus is an exceptional trace fossil due to its very thin diameter (mostly less than 1 mm) and common pyritic filling. It is ubiquitous in some fine-grained sediments, where it has been interpreted as a burrow formed deeper than any other trace fossils, below the redox boundary. Trichichnus , formerly referred to as deeply burrowed invertebrates, has been found as remnant of a fossilized intrasediment bacterial mat that is pyritized. As visualized in 3-D by means of X-ray computed microtomography scanner, Trichichnus forms dense filamentous fabric, which reflects that it is produced by modern large, mat-forming, sulfide-oxidizing bacteria, belonging mostly to Thioploca -related taxa, which are able to house a complex bacterial consortium. Several stages of Trichichnus formation, including filamentous, bacterial mat and its pyritization, are proposed to explain an electron exchange between oxic and suboxic/anoxic layers in the sediment. Therefore, Trichichnus can be considered a fossilized "electric wire".

  16. Improved Scanners for Microscopic Hyperspectral Imaging

    Science.gov (United States)

    Mao, Chengye

    2009-01-01

    Improved scanners to be incorporated into hyperspectral microscope-based imaging systems have been invented. Heretofore, in microscopic imaging, including spectral imaging, it has been customary to either move the specimen relative to the optical assembly that includes the microscope or else move the entire assembly relative to the specimen. It becomes extremely difficult to control such scanning when submicron translation increments are required, because the high magnification of the microscope enlarges all movements in the specimen image on the focal plane. To overcome this difficulty, in a system based on this invention, no attempt would be made to move either the specimen or the optical assembly. Instead, an objective lens would be moved within the assembly so as to cause translation of the image at the focal plane: the effect would be equivalent to scanning in the focal plane. The upper part of the figure depicts a generic proposed microscope-based hyperspectral imaging system incorporating the invention. The optical assembly of this system would include an objective lens (normally, a microscope objective lens) and a charge-coupled-device (CCD) camera. The objective lens would be mounted on a servomotor-driven translation stage, which would be capable of moving the lens in precisely controlled increments, relative to the camera, parallel to the focal-plane scan axis. The output of the CCD camera would be digitized and fed to a frame grabber in a computer. The computer would store the frame-grabber output for subsequent viewing and/or processing of images. The computer would contain a position-control interface board, through which it would control the servomotor. There are several versions of the invention. An essential feature common to all versions is that the stationary optical subassembly containing the camera would also contain a spatial window, at the focal plane of the objective lens, that would pass only a selected portion of the image. In one version

  17. Single wire drift chamber design

    Energy Technology Data Exchange (ETDEWEB)

    Krider, J.

    1987-03-30

    This report summarizes the design and prototype tests of single wire drift chambers to be used in Fermilab test beam lines. The goal is to build simple, reliable detectors which require a minimum of electronics. Spatial resolution should match the 300 ..mu..m rms resolution of the 1 mm proportional chambers that they will replace. The detectors will be used in beams with particle rates up to 20 KHz. Single track efficiency should be at least 99%. The first application will be in the MT beamline, which has been designed for calibration of CDF detectors. A set of four x-y modules will be used to track and measure the momentum of beam particles.

  18. FAST scan

    DEFF Research Database (Denmark)

    Müller, Anna

    FAST-skanning er en metode, der har til formål at hurtigt diagnosticere fri væske i bughulen hos traumapatienter og andre akutte patienter. Denne skanningsteknik blev først introduceret til hunde i 2004, og omfatter ultralydsskanning af specifikke punkter i bughulen, hvor der er stor chance....../sorte) områder. I dag bruges FAST-skanning meget hyppigt indenfor human og veterinær akutmedicin. Det kan ses som et værktøj for dyrlæger som ikke arbejder med ultralyd til daglig. FAST-skanning har mange fordele; proceduren er effektiv og kan tage under 3 minutter, men har alligevel høj diagnostisk værdi. Det...... nødvendigt. Det skal dog understreges, at de abdominale organer ikke undersøges specifikt. Det kan være svært at skelne mellem væske i peritonealhulen og i det retroperitoneale rum. Man kan heller ikke karakterisere væsken og derved skelne mellem f.eks. blod, pus eller urin. Siden FAST-skanning blev...

  19. Fast ejendom

    DEFF Research Database (Denmark)

    Pagh, Peter

    Bogen omfatter en gennemgang af lovgivning, praksis og teori vedrørende køb af fast ejendom og offentligretlig og privatretlig regulering. Bogen belyser bl.a. de privatretlige emner: købers misligholdelsesbeføjelser, servitutter, naboret, hævd og erstatningsansvar for miljøskader samt den...

  20. Characterization of a Large, Low-Cost 3D Scanner

    Directory of Open Access Journals (Sweden)

    Jeremy Straub

    2015-01-01

    Full Text Available Imagery-based 3D scanning can be performed by scanners with multiple form factors, ranging from small and inexpensive scanners requiring manual movement around a stationary object to large freestanding (nearly instantaneous units. Small mobile units are problematic for use in scanning living creatures, which may be unwilling or unable to (or for the very young and animals, unaware of the need to hold a fixed position for an extended period of time. Alternately, very high cost scanners that can capture a complete scan within a few seconds are available, but they are cost prohibitive for some applications. This paper seeks to assess the performance of a large, low-cost 3D scanner, presented in prior work, which is able to concurrently capture imagery from all around an object. It provides the capabilities of the large, freestanding units at a price point akin to the smaller, mobile ones. This allows access to 3D scanning technology (particularly for applications requiring instantaneous imaging at a lower cost. Problematically, prior analysis of the scanner’s performance was extremely limited. This paper characterizes the efficacy of the scanner for scanning both inanimate objects and humans. Given the importance of lighting to visible light scanning systems, the scanner’s performance under multiple lighting configurations is evaluated, characterizing its sensitivity to lighting design.

  1. Moths on the Flatbed Scanner: The Art of Joseph Scheer.

    Science.gov (United States)

    Buchmann, Stephen L

    2011-12-14

    During the past decade a few artists and even fewer entomologists discovered flatbed scanning technology, using extreme resolution graphical arts scanners for acquiring high magnification digital images of plants, animals and inanimate objects. They are not just for trip receipts anymore. The special attributes of certain scanners, to image thick objects is discussed along with the technical features of the scanners including magnification, color depth and shadow detail. The work of pioneering scanner artist, Joseph Scheer from New York's Alfred University is highlighted. Representative flatbed-scanned images of moths are illustrated along with techniques to produce them. Collecting and preparing moths, and other objects, for scanning are described. Highlights of the Fulbright sabbatical year of professor Scheer in Arizona and Sonora, Mexico are presented, along with comments on moths in science, folklore, art and pop culture. The use of flatbed scanners is offered as a relatively new method for visualizing small objects while acquiring large files for creating archival inkjet prints for display and sale.

  2. Moths on the Flatbed Scanner: The Art of Joseph Scheer

    Directory of Open Access Journals (Sweden)

    Stephen L. Buchmann

    2011-12-01

    Full Text Available During the past decade a few artists and even fewer entomologists discovered flatbed scanning technology, using extreme resolution graphical arts scanners for acquiring high magnification digital images of plants, animals and inanimate objects. They are not just for trip receipts anymore. The special attributes of certain scanners, to image thick objects is discussed along with the technical features of the scanners including magnification, color depth and shadow detail. The work of pioneering scanner artist, Joseph Scheer from New York’s Alfred University is highlighted. Representative flatbed-scanned images of moths are illustrated along with techniques to produce them. Collecting and preparing moths, and other objects, for scanning are described. Highlights of the Fulbright sabbatical year of professor Scheer in Arizona and Sonora, Mexico are presented, along with comments on moths in science, folklore, art and pop culture. The use of flatbed scanners is offered as a relatively new method for visualizing small objects while acquiring large files for creating archival inkjet prints for display and sale.

  3. Sliding-mode control combined with improved adaptive feedforward for wafer scanner

    Science.gov (United States)

    Li, Xiaojie; Wang, Yiguang

    2018-03-01

    In this paper, a sliding-mode control method combined with improved adaptive feedforward is proposed for wafer scanner to improve the tracking performance of the closed-loop system. Particularly, In addition to the inverse model, the nonlinear force ripple effect which may degrade the tracking accuracy of permanent magnet linear motor (PMLM) is considered in the proposed method. The dominant position periodicity of force ripple is determined by using the Fast Fourier Transform (FFT) analysis for experimental data and the improved feedforward control is achieved by the online recursive least-squares (RLS) estimation of the inverse model and the force ripple. The improved adaptive feedforward is given in a general form of nth-order model with force ripple effect. This proposed method is motivated by the motion controller design of the long-stroke PMLM and short-stroke voice coil motor for wafer scanner. The stability of the closed-loop control system and the convergence of the motion tracking are guaranteed by the proposed sliding-mode feedback and adaptive feedforward methods theoretically. Comparative experiments on a precision linear motion platform can verify the correctness and effectiveness of the proposed method. The experimental results show that comparing to traditional method the proposed one has better performance of rapidity and robustness, especially for high speed motion trajectory. And, the improvements on both tracking accuracy and settling time can be achieved.

  4. Restoration of Hyperspectral Push-Broom Scanner Data

    DEFF Research Database (Denmark)

    Larsen, Rasmus; Nielsen, Allan Aasbjerg; Conradsen, Knut

    1997-01-01

    Several effects combine to distort the multispectral data that are obtained from push-broom scanners. We develop an algorithm for restoration of such data, illustrated on images from the ROSIS scanner. In push-broom scanners variation between elements in the detector array results in a strong......, for instance over water.Following these initial corrections we use minimum/maximum autocorrelation factor (MAF) analysis in order to separate the spatially coherent signal components from the noise components. The MAF transformation is a linear transformation into new orthogonal variables that are ordered...... by decreasing autocorrelation. In this way noise channels (with low autocorrelation) can be identified and cleaned or eliminated. Also, the MAF transformation enables us to isolate electronic or aircraft engine induced noise components that have a special spatial structure. Subsequent inverse transformation...

  5. Nodular melanoma serendipitously detected by airport full body scanners.

    Science.gov (United States)

    Mayer, Jonathan E; Adams, Brian B

    2015-01-01

    Nodular melanoma is the most dangerous form of melanoma and often evades early detection. We present a frequently traveling businessman whose nodular melanoma was detected by airport full body scanners. For about 20 flights over 2 months, the airport full body scanners singled out an area on his left lower leg for a pat-down. Dermatologic examination discovered a nodular melanoma in this area, and after surgical excision, the man traveled without incident. This case raises the possibility of using full body imaging in the detection of melanomas, especially of the nodular subtype. In its current form, full body scanning would most likely not be sensitive or specific enough to become a recommended screening tool. Nonetheless, for travelers with areas repeatedly singled out by the machines without a known justification, airport scanners could serve as incidental free screening for suspicious nodular lesions that should prompt dermatologist referral. © 2014 S. Karger AG, Basel.

  6. Calibration procedure for a laser triangulation scanner with uncertainty evaluation

    Science.gov (United States)

    Genta, Gianfranco; Minetola, Paolo; Barbato, Giulio

    2016-11-01

    Most of low cost 3D scanning devices that are nowadays available on the market are sold without a user calibration procedure to correct measurement errors related to changes in environmental conditions. In addition, there is no specific international standard defining a procedure to check the performance of a 3D scanner along time. This paper aims at detailing a thorough methodology to calibrate a 3D scanner and assess its measurement uncertainty. The proposed procedure is based on the use of a reference ball plate and applied to a triangulation laser scanner. Experimental results show that the metrological performance of the instrument can be greatly improved by the application of the calibration procedure that corrects systematic errors and reduces the device's measurement uncertainty.

  7. Dental impressions using 3D digital scanners: virtual becomes reality.

    Science.gov (United States)

    Birnbaum, Nathan S; Aaronson, Heidi B

    2008-10-01

    The technologies that have made the use of three-dimensional (3D) digital scanners an integral part of many industries for decades have been improved and refined for application to dentistry. Since the introduction of the first dental impressioning digital scanner in the 1980s, development engineers at a number of companies have enhanced the technologies and created in-office scanners that are increasingly user-friendly and able to produce precisely fitting dental restorations. These systems are capable of capturing 3D virtual images of tooth preparations, from which restorations may be fabricated directly (ie, CAD/CAM systems) or fabricated indirectly (ie, dedicated impression scanning systems for the creation of accurate master models). The use of these products is increasing rapidly around the world and presents a paradigm shift in the way in which dental impressions are made. Several of the leading 3D dental digital scanning systems are presented and discussed in this article.

  8. Minimum quench energy measurement for superconducting wires

    International Nuclear Information System (INIS)

    Seo, K.; Morita, M.; Nakamura, S.; Yamada, T.; Jizo, Y.

    1996-01-01

    The authors have developed a new method of measuring minimum quench energy (MQE) of superconducting wire. There have been conventional methods using heating wires, whose diameters are ∼0.1mm and are glued by epoxy resin. When they induce a pulse heat to superconducting wires, a duration of the pulse must be several hundreds micro seconds to demonstrate actual disturbances (for instance wire motion) in a superconducting magnet. In spite of this fact, thermal diffusion time constants of the conventional heaters are larger than the duration of the actual disturbance, because of these electrical insulator of the heating wire and the epoxy bind. Therefore, this kind of heater is not able to demonstrate the actual disturbance. To solve this problem, they have proposed a new constitution of a heater. In the method, heat generation is introduced in high resistive layer on a surface of a superconducting wire. The high resistive layer is consist of carbon paste. The thickness of the carbon paste layer is ∼20microm, thus a time constant of this heater is expected to be small enough to demonstrate the actual disturbance. Adopting the new method to the MQE measurement, they successfully evaluate MQE of superconducting wires with high precision. Several results are introduced in this paper

  9. Wire pad chamber for LHCb muon system

    CERN Document Server

    Botchine, B; Lazarev, V A; Sagidova, N; Vorobev, A P; Vorobyov, A; Vorobyov, Alexei

    2000-01-01

    2000-003 Wire pad chambers (WPC) have been proposed for the outer Region 4 of the LHCb Muon System. These are double gap MWPCs with small wire spacing allowing to obtain 99% detection efficiency in a 20 ns time window. The chambers have a rectangular shape with the vertical dimension from 20 cm in Station 1 to 30 cm in Station 5. The horizontal dimensions will be different with the maximal size of 3 meters in Station 5. The wires are in the vertical direction. The short wire length allows to use small wire spacing needed for high time resolution. Also, this helps to obtain the uniform gas gain over the whole chamber area. The WPC has one row of the wire pads formed by grouping wires in separate readout channels. Four WPC prototypes have been built at PNPI and tested in the PS beam at CERN. Here we report on the results from these tests. Also, the results of simulation of the WPC performance are presented.

  10. Nanosecond electrical explosion of thin aluminum wire in vacuum: experimental and computational investigations

    International Nuclear Information System (INIS)

    Cochrane, Kyle Robert; Struve, Kenneth William; Rosenthal, Stephen Edgar; McDaniel, Dillon Heirman; Sarkisov, Gennady Sergeevich; Deeney, Christopher

    2004-01-01

    The experimental and computational investigations of nanosecond electrical explosion of thin Al wire in vacuum are presented. We have demonstrated that increasing the current rate leads to increased energy deposited before voltage collapse. Laser shadowgrams of the overheated Al core exhibit axial stratification with a ∼100 (micro)m period. The experimental evidence for synchronization of the wire expansion and light emission with voltage collapse is presented. Two-wavelength interferometry shows an expanding Al core in a low-ionized gas condition with increasing ionization toward the periphery. Hydrocarbons are indicated in optical spectra and their influence on breakdown physics is discussed. The radial velocity of low-density plasma reaches a value of ∼100 km/s. The possibility of an overcritical phase transition due to high pressure is discussed. 1D MHD simulation shows good agreement with experimental data. MHD simulation demonstrates separation of the exploding wire into a high-density cold core and a low-density hot corona as well as fast rejection of the current from the wire core to the corona during voltage collapse. Important features of the dynamics for wire core and corona follow from the MHD simulation and are discussed.

  11. Transport of energy by ultraintense laser-generated electrons in nail-wire targets

    Science.gov (United States)

    Ma, T.; Key, M. H.; Mason, R. J.; Akli, K. U.; Daskalova, R. L.; Freeman, R. R.; Green, J. S.; Highbarger, K.; Jaanimagi, P. A.; King, J. A.; Lancaster, K. L.; Hatchett, S. P.; Mackinnon, A. J.; MacPhee, A. G.; Norreys, P. A.; Patel, P. K.; Stephens, R. B.; Theobald, W.; Van Woerkom, L. D.; Wei, M. S.; Wilks, S. C.; Beg, F. N.

    2009-11-01

    Nail-wire targets (20 μm diameter copper wires with 80 μm hemispherical head) were used to investigate energy transport by relativistic fast electrons generated in intense laser-plasma interactions. The targets were irradiated using the 300 J, 1 ps, and 2×1020 Wṡcm-2 Vulcan laser at the Rutherford Appleton Laboratory. A spherically bent crystal imager, a highly ordered pyrolytic graphite spectrometer, and single photon counting charge-coupled device gave absolute Cu Kα measurements. Results show a concentration of energy deposition in the head and an approximately exponential fall-off along the wire with about 60 μm 1/e decay length due to resistive inhibition. The coupling efficiency to the wire was 3.3±1.7% with an average hot electron temperature of 620±125 keV. Extreme ultraviolet images (68 and 256 eV) indicate additional heating of a thin surface layer of the wire. Modeling using the hybrid E-PLAS code has been compared with the experimental data, showing evidence of resistive heating, magnetic trapping, and surface transport.

  12. Online process monitoring at quasi-simultaneous laser transmission welding using a 3D-scanner with integrated pyrometer

    Science.gov (United States)

    Schmailzl, A.; Steger, S.; Dostalek, M.; Hierl, S.

    2016-03-01

    Quasi-simultaneous laser transmission welding is a well-known joining technique for thermoplastics and mainly used in the automotive as well as in the medical industry. For process control usually the so called set-path monitoring is used, where the weld is specified as "good" if the irradiation time is inside a defined confidence interval. However, the detection of small-sized gaps or thermal damaged zones is not possible with this technique. The analyzation of the weld seam temperature during welding offers the possibility to overcome this problem. In this approach a 3D-scanner is used instead of a scanner with flat-field optic. By using a pyrometer in combination with a 3D-scanner no color-corrected optic is needed in order to provide that laser- and detection-spot are concentric. Experimental studies on polyethylene T-joints have shown that the quality of the signal is adequate, despite the use of an optical setup with a long working distance and a small optical aperture. The effects on temperature are studied for defects like a gap in the joining zone. Therefore a notch was milled into the absorbent polymer. In case of producing housings for electronic parts the effect of an electrical wire between the joining partners is also investigated. Both defects can be identified by a local temperature deviation even at a feed rate of four meters per second. Furthermore a strategy for signal-processing is demonstrated. By this, remaining defects can be identified. Consequently an online detection of local defects is possible, which makes a dynamic process control feasible.

  13. Development of the Shimadzu computed tomographic scanner SCT-200N

    International Nuclear Information System (INIS)

    Ishihara, Hiroshi; Yamaoka, Nobuyuki; Saito, Masahiro

    1982-01-01

    The Shimadzu Computed Tomographic Scanner SCT-200N has been developed as an ideal CT scanner for diagnosing the head and spine. Due to the large aperture, moderate scan time and the Zoom Scan Mode, any part of the body can be scanned. High quality image can be obtained by adopting the precisely stabilized X-ray unit and densely packed array of 64-detectors. As for its operation, capability of computed radiography (CR) prior to patient positioning and real time reconstruction ensure efficient patient through-put. Details of the SCT-200N are described in this paper. (author)

  14. Scanner baseliner monitoring and control in high volume manufacturing

    Science.gov (United States)

    Samudrala, Pavan; Chung, Woong Jae; Aung, Nyan; Subramany, Lokesh; Gao, Haiyong; Gomez, Juan-Manuel

    2016-03-01

    We analyze performance of different customized models on baseliner overlay data and demonstrate the reduction in overlay residuals by ~10%. Smart Sampling sets were assessed and compared with the full wafer measurements. We found that performance of the grid can still be maintained by going to one-third of total sampling points, while reducing metrology time by 60%. We also demonstrate the feasibility of achieving time to time matching using scanner fleet manager and thus identify the tool drifts even when the tool monitoring controls are within spec limits. We also explore the scanner feedback constant variation with illumination sources.

  15. Cyclone: A laser scanner for mobile robot navigation

    Science.gov (United States)

    Singh, Sanjiv; West, Jay

    1991-09-01

    Researchers at Carnegie Mellon's Field Robotics Center have designed and implemented a scanning laser rangefinder. The device uses a commercially available time-of-flight ranging instrument that is capable of making up to 7200 measurements per second. The laser beam is reflected by a rotating mirror, producing up to a 360 degree view. Mounted on a robot vehicle, the scanner can be used to detect obstacles in the vehicle's path or to locate the robot on a map. This report discusses the motivation, design, and some applications of the scanner.

  16. Localization of a mobile laser scanner via dimensional reduction

    Science.gov (United States)

    Lehtola, Ville V.; Virtanen, Juho-Pekka; Vaaja, Matti T.; Hyyppä, Hannu; Nüchter, Andreas

    2016-11-01

    We extend the concept of intrinsic localization from a theoretical one-dimensional (1D) solution onto a 2D manifold that is embedded in a 3D space, and then recover the full six degrees of freedom for a mobile laser scanner with a simultaneous localization and mapping algorithm (SLAM). By intrinsic localization, we mean that no reference coordinate system, such as global navigation satellite system (GNSS), nor inertial measurement unit (IMU) are used. Experiments are conducted with a 2D laser scanner mounted on a rolling prototype platform, VILMA. The concept offers potential in being extendable to other wheeled platforms.

  17. Resonant tunneling of electrons in quantum wires

    International Nuclear Information System (INIS)

    Krive, I.V.; Shekhter, R.I.; Jonson, M.; Krive, I.V.

    2010-01-01

    We considered resonant electron tunneling in various nanostructures including single wall carbon nanotubes, molecular transistors and quantum wires formed in two-dimensional electron gas. The review starts with a textbook description of resonant tunneling of noninteracting electrons through a double-barrier structure. The effects of electron-electron interaction in sequential and resonant electron tunneling are studied by using Luttinger liquid model of electron transport in quantum wires. The experimental aspects of the problem (fabrication of quantum wires and transport measurements) are also considered. The influence of vibrational and electromechanical effects on resonant electron tunneling in molecular transistors is discussed.

  18. Problems associated with iridium-192 wire implants

    International Nuclear Information System (INIS)

    Arnott, S.J.; Law, J.; Ash, D.; Flynn, A.; Paine, C.H.; Durrant, K.R.; Barber, C.D.; Dixon-Brown, A.

    1985-01-01

    Three incidents are reported, from different radiotherapy centres, in which an implanted iridium-192 wire remained in the tissues of a patient after withdrawal of the plastic tubing in which it was contained. In each case the instrument used to cut the wire had probably formed a hook on the end of the wire which caused it to catch in the tissues. Detailed recommendations are made for avoiding such incidents in the future, the most important of which is that the patient should be effectively monitored after the supposed removal of all radioactive sources. (author)

  19. Investigation of wire motion in superconducting magnets

    International Nuclear Information System (INIS)

    Ogitsu, T.; Tsuchiya, K.; Devred, A.

    1990-09-01

    The large Lorentz forces occuring during the excitation of superconducting magnets can provoke sudden motions of wire, which eventually release enough energy to trigger a quench. These wire motions are accompanied by two electromagnetic effects: an induced emf along the moved wire, and a local change in flux caused by the minute dislocation of current. Both effects cause spikes in the coil voltage. Voltage data recorded during the excitation of a superconducting quadrupole magnet which early exhibit such events are here reported. Interpretations of the voltage spikes in terms of energy release are also presented, leading to insights on the spectrum of the disturbances which occur in real magnets. 15 refs

  20. A three-dimensional evaluation of a laser scanner and a touch-probe scanner.

    Science.gov (United States)

    Persson, Anna; Andersson, Matts; Oden, Agneta; Sandborgh-Englund, Gunilla

    2006-03-01

    The fit of a dental restoration depends on quality throughout the entire manufacturing process. There is difficulty in assessing the surface topography of an object with a complex form, such as teeth, since there is no exact reference form. The purpose of this study was to determine the repeatability and relative accuracy of 2 dental surface digitization devices. A computer-aided design (CAD) technique was used for evaluation to calculate and present the deviations 3-dimensionally. Ten dies of teeth prepared for complete crowns were fabricated in presintered yttria-stabilized tetragonal zirconia (Y-TZP). The surfaces were digitized 3 times each with an optical or mechanical digitizer. The number of points in the point clouds from each reading were calculated and used as the CAD reference model (CRM). Alignments were performed by registration software that works by minimizing a distance criterion. In color-difference maps, the distribution of the discrepancies between the surfaces in the CRM and the 3-dimensional surface models was identified and located. The repeatability of both scanners was within 10 microm, based on SD and absolute mean values. The qualitative evaluation resulted in an even distribution of the deviations in the optical digitizer, whereas the dominating part of the surfaces in the mechanical digitizer showed no deviations. The relative accuracy of the 2 surface digitization devices was within +/- 6 microm, based on median values. The repeatability of the optical digitizer was comparable with the mechanical digitization device, and the relative accuracy was similar.

  1. Advanced high speed X-ray CT scanner for measurement and visualization of multi-phase flow

    International Nuclear Information System (INIS)

    Hori, Keiichi; Fujimoto, Tetsuro; Kawanishi, Kohei; Nishikawa, Hideo

    1998-01-01

    The development of an ultra-fast X-ray computed tomography (CT) scanner has been performed. The object of interest is in a transient or unsettled state, which makes the conventional CT scanner inappropriate. A concept of electrical switching of electron beam of X-ray generation unit is adopted to reduce the scanning time instead of a mechanical motion adopted by a conventional CT scanner. The mechanical motion is a major obstacle to improve the scanning speed. A prototype system with a scanning time of 3.6 milliseconds was developed at first. And, the feasibility was confirmed to measure the dynamic events of two-phase flow. However, faster scanning speed is generally required for the practical use in the thermalhydraulics research field. Therefore, the development of advanced type has been performed. This advanced type can operate under the scanning time of 0.5 milliseconds and is applicable for the measurement of the multi-phase flow with velocity up to 4-5 m/s. (author)

  2. 47 CFR 76.802 - Disposition of cable home wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Disposition of cable home wiring. 76.802... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.802 Disposition of cable home wiring... cable operator shall not remove the cable home wiring unless it gives the subscriber the opportunity to...

  3. Automatic reel controls filler wire in welding machines

    Science.gov (United States)

    Millett, A. V.

    1966-01-01

    Automatic reel on automatic welding equipment takes up slack in the reel-fed filler wire when welding operation is terminated. The reel maintains constant, adjustable tension on the wire during the welding operation and rewinds the wire from the wire feed unit when the welding is completed.

  4. 47 CFR 32.2321 - Customer premises wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Customer premises wiring. 32.2321 Section 32... Customer premises wiring. (a) This account shall include all amounts transferred from the former Account 232, Station Connections, inside wiring subclass. (b) Embedded Customer Premises Wiring is that...

  5. 30 CFR 77.701-3 - Grounding wires; capacity.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity. 77.701-3 Section 77... MINES Grounding § 77.701-3 Grounding wires; capacity. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames, casings, and other metallic enclosures, such grounding wires will be...

  6. Wire Bonder: Kulicke and Soffa Model 4526

    Data.gov (United States)

    Federal Laboratory Consortium — Description:CORAL Name: Wire BonderNeeds Description.Scientific Opportunities / Applications:Wedge bonderSemi-automatic and manual modesIndependent Z-axis control,...

  7. Beam Profiling through Wire Chambing Tracking

    CERN Document Server

    Nash, W

    2013-01-01

    This note describes the calibration of the Delay Wire Chambers (DWCs) used during test runs of CALICE’s Tungsten Digital Hadron Calorimeter (W-DHCAL) prototype in CERN’s SPS beam line (10 – 300 GeV).

  8. Copyright and Wire Broadcasting Under Belgian Law

    Science.gov (United States)

    Namurois, Albert

    1975-01-01

    A discussion of a case whereby substantial damages, if not criminal proceedings, will sanction, according to circumstances, both television organizations and those who in certain conditions distribute their programs by wire or communicate them to the public. (Author/HB)

  9. Josephson junction arrays and superconducting wire networks

    International Nuclear Information System (INIS)

    Lobb, C.J.

    1992-01-01

    Techniques used to fabricate integrated circuits make it possible to construct superconducting networks containing as many as 10 6 wires or Josephson junctions. Such networks undergo phase transitions from resistive high-temperature states to ordered low-resistance low-temperature states. The nature of the phase transition depends strongly on controllable parameters such as the strength of the superconductivity in each wire or junction and the external magnetic field. This paper will review the physics of these phase transitions, starting with the simplest zero-magnetic field case. This leads to a Kosterlitz-Thouless transition when the junctions or wires are weak, and a simple mean-field fransition when the junctions or wires are strong. Rich behavior, resulting from frustration, occurs in the presence of a magnetic field. (orig.)

  10. Highly stretchable wrinkled gold thin film wires.

    Science.gov (United States)

    Kim, Joshua; Park, Sun-Jun; Nguyen, Thao; Chu, Michael; Pegan, Jonathan D; Khine, Michelle

    2016-02-08

    With the growing prominence of wearable electronic technology, there is a need to improve the mechanical reliability of electronics for more demanding applications. Conductive wires represent a vital component present in all electronics. Unlike traditional planar and rigid electronics, these new wearable electrical components must conform to curvilinear surfaces, stretch with the body, and remain unobtrusive and low profile. In this paper, the piezoresistive response of shrink induced wrinkled gold thin films under strain demonstrates robust conductive performance in excess of 200% strain. Importantly, the wrinkled metallic thin films displayed negligible change in resistance of up to 100% strain. The wrinkled metallic wires exhibited consistent performance after repetitive strain. Importantly, these wrinkled thin films are inexpensive to fabricate and are compatible with roll to roll manufacturing processes. We propose that these wrinkled metal thin film wires are an attractive alternative to conventional wires for wearable applications.

  11. Tensosensitivity of the Hot-Wire Probe

    National Research Council Canada - National Science Library

    Pak, A

    2002-01-01

    ...., on the anemometer type. In a constant current anemometer, it is possible to measure and separate out the noise moving to the electric circuit of the anemometer, it is not the case with hot-wire anemometers of other types...

  12. Molecular wires, switches and memories

    Science.gov (United States)

    Chen, Jia

    Molecular electronics, an emerging field, makes it possible to build individual molecules capable of performing functions identical or analogous to present- day conductors, switches, or memories. These individual molecules, with a nano-meter scale characteristic length, can be designed and chemically synthesized with specific atoms, geometries and charge distribution. This thesis focuses on the design, and measurements of molecular wires, and related strategically engineered structures-molecular switches and memories. The experimental system relies on a thermodynamically driven self-assembling process to attach molecules onto substrate surfaces without intervention from outside. The following topics will be discussed: directed nanoscale manipulation of self-assembled molecules using scanning tunneling microscope; investigation on through-bond transport of nanoscale symmetric metal/conjugated self- assembled monolayers (SAM)/metal junctions, where non- Ohmic thermionic emission was observed to be the dominant process, with isocyanide-Pd contacts showing the lowest thermionic barrier of 0.22 eV; the first realization of robust and large reversible switching behavior in an electronic device that utilizes molecules containing redox centers as the active component, exhibiting negative differential resistance (NDR) and large on-off peak-to-valley ratio (PVR); observation of erasable storage of higher conductivity states in these redox- center containing molecular devices, and demonstration of a two-terminal electronically programmable and erasable molecular memory cell with long bit retention time.

  13. Load-Deflection and Friction Properties of PEEK Wires as Alternative Orthodontic Wires.

    Science.gov (United States)

    Tada, Yoshifumi; Hayakawa, Tohru; Nakamura, Yoshiki

    2017-08-09

    Polyetheretherketone (PEEK) is now attracting attention as an alternative to metal alloys in the dental field. In the present study, we evaluated the load-deflection characteristics of PEEK wires in addition to their frictional properties. Three types of PEEK wires are used: two sizes of rectangular shape, 0.016 × 0.022 in² and 0.019 × 0.025 in² (19-25PEEK), and rounded shape, diameter 0.016 in (16PEEK). As a control, Ni-Ti orthodontic wire, diameter 0.016 in, was used. The three-point bending properties were evaluated in a modified three-point bending system for orthodontics. The static friction between the orthodontic wire and the bracket was also measured. The load-deflection curves were similar among Ni-Ti and PEEK wires, except for 16PEEK with slot-lid ligation. The bending force of 19-25PEEK wire was comparable with that of Ni-Ti wire. 19-25PEEK showed the highest load at the deflection of 1500 μm ( p 0.05). No significant difference was seen in static friction between all three PEEK wires and Ni-Ti wire ( p > 0.05). It is suggested that 19-25PEEK will be applicable for orthodontic treatment with the use of slot-lid ligation.

  14. Audio wiring guide how to wire the most popular audio and video connectors

    CERN Document Server

    Hechtman, John

    2012-01-01

    Whether you're a pro or an amateur, a musician or into multimedia, you can't afford to guess about audio wiring. The Audio Wiring Guide is a comprehensive, easy-to-use guide that explains exactly what you need to know. No matter the size of your wiring project or installation, this handy tool provides you with the essential information you need and the techniques to use it. Using The Audio Wiring Guide is like having an expert at your side. By following the clear, step-by-step directions, you can do professional-level work at a fraction of the cost.

  15. Biliary cannulation with a guide wire in pancreatic duct

    International Nuclear Information System (INIS)

    Castano, Rodrigo; Nunez, Edilberto; Sanin, Eugenio

    2009-01-01

    The angular stone in endoscopic cholangiography is an a traumatic and fast biliary cannulation, which results in the success of the procedure. In this series of 10 patients an easy technique is described that helps to cannulate a difficult biliary conduit. Methods. In cases of repeatedly cannulation of pancreatic duct and not selectively the biliary tract; it is suggested to leave the guide wire in the middle of the Wirsung duct and to retire the cannula or sphincterotome. The cannula or sphincterotome is reintroduced by the work channel next to the guide wire in the pancreatic conduit. With the guide in the pancreatic duct the cannula advances with better direction, stability and firmness of papilla. Results. This technique cases was used in 10 patients (6 hospitalized and 4 ambulatory) and was successful in all the patients, avoiding the necessity of the access to the biliary route by the technique of the pre cut. No complication was documented. Conclusions. Use of this technique can help to reduce the number of sphincterotomies by pre cuts, with increased risks of pancreatitis, bleeding and perforation. The proposed technique can help us in any difficult cannulation of the biliary route.

  16. Note: Improved wire-wound heater.

    Science.gov (United States)

    Steinmann, Ricardo G; Vitoux, Hugo

    2015-01-01

    The authors have measured, at cryogenic temperature, the upper limit of the heat transfer in different configurations of a wire-wound heater. We found that the heat transferred has an upper limit of about 15 W/cm(2) and is dependent on the diameter of the wire. In this paper, we present three ways of increasing the heat transferred by this type of heater and its application in different continuous flow cryostats.

  17. Graphene wire medium: Homogenization and application

    DEFF Research Database (Denmark)

    Andryieuski, Andrei; Chigrin, Dmitry N.; Lavrinenko, Andrei

    2012-01-01

    In this contribution we analyze numerically the optical properties of the graphene wire medium, which unit cell consists of a stripe of graphene embedded into dielectric. We propose a simple method for retrieval of the isofrequency contour and effective permittivity tensor. As an example...... of the graphene wire medium application we demonstrate a reconfigurable hyperlens for the terahertz subwavelength imaging capable of resolving two sources with separation λ0/5 in the far-field....

  18. Novel use of the "buddy"wire.

    LENUS (Irish Health Repository)

    O'Hare, A

    2008-12-29

    Summary: During interventional procedures the tortuosity of the vasculature hampers catheter stability. The buddy wire may be used to aid and maintain vascular access.We describe a case of acute subarachnoid haemorrhage secondary to dissecting aneurysm of the vertebral artery.We discuss the value of the buddy wire during balloon occlusion of the vertebral artery not as it is typically used, but to actually prevent the balloon repeatedly entering the posterior inferior cerebellar artery during the procedure.

  19. A Magnetic Sensor with Amorphous Wire

    Directory of Open Access Journals (Sweden)

    Dongfeng He

    2014-06-01

    Full Text Available Using a FeCoSiB amorphous wire and a coil wrapped around it, we have developed a sensitive magnetic sensor. When a 5 mm long amorphous wire with the diameter of 0.1 mm was used, the magnetic field noise spectrum of the sensor was about 30 pT/ÖHz above 30 Hz. To show the sensitivity and the spatial resolution, the magnetic field of a thousand Japanese yen was scanned with the magnetic sensor.

  20. COBRA-IV wire wrap data comparisons

    International Nuclear Information System (INIS)

    Donovan, T.E.; George, T.L.; Wheeler, C.L.

    1979-02-01

    Thermal hydraulic analyses of hexagonally packed wire-wrapped fuel assemblies are complicated by the induced crossflow between adjacent subchannels. The COBRA-IV computer code simultaneously solves the hydrodynamics and thermodynamics of fuel assemblies. The modifications and the results are presented which are predicted by the COBRA-IV calculation. Comparisons are made with data measured in five experimental models of a wire-wrapped fuel assembly

  1. Wiring System Diagnostic Techniques for Legacy Aircraft

    Science.gov (United States)

    2003-02-01

    Reunions des specialistes des techniques de estion du cycle de vie pour vehicules aeriens vieillissants ] To order the complete compilation report, use...Ageing Mechanisms and Control. Specialists’ Meeting on Life Management Techniques for Ageing Air Vehicles [Les mecanismes vieillissants et le controle...be identified. Additionally, wiring failures tend to be intermittent in nature and can take considerable time to isolate. Wire modifications and

  2. Feature-space transformation improves supervised segmentation across scanners

    DEFF Research Database (Denmark)

    van Opbroek, Annegreet; Achterberg, Hakim C.; de Bruijne, Marleen

    2015-01-01

    Image-segmentation techniques based on supervised classification generally perform well on the condition that training and test samples have the same feature distribution. However, if training and test images are acquired with different scanners or scanning parameters, their feature distributions...

  3. Magnetic actuation for MEMS scanners for retinal scanning displays

    Science.gov (United States)

    Yan, Jun; Luanava, Selso; Casasanta, Vincenzo

    2003-01-01

    We discuss magnetic actuation for Microvision"s bi-axial scanners for retinal scanning displays. Compared to the common side-magnet and moving-coil approach, we have designed, assembled and tested a novel magnet configuration, with magnets above and below the moving coil. This design reduces the magnet sizes significantly without sacrificing performance, and opens further improvement paths as well.

  4. Benchmarking Advanced Control Algorithms for a Laser Scanner System

    DEFF Research Database (Denmark)

    Stoustrup, Jakob; Ordys, A.W.; Smillie, I.

    1996-01-01

    The paper describes tests performed on the laser scanner system toassess feasibility of modern control techniques in achieving a requiredperformance in the trajectory following problem. The two methods tested areQTR H-infinity and Predictive Control. The results are ilustated ona simulation example....

  5. Teach Your Computer to Read: Scanners and Optical Character Recognition.

    Science.gov (United States)

    Marsden, Jim

    1993-01-01

    Desktop scanners can be used with a software technology called optical character recognition (OCR) to convert the text on virtually any paper document into an electronic form. OCR offers educators new flexibility in incorporating text into tests, lesson plans, and other materials. (MLF)

  6. The economic potential of CT scanners for hardwood sawmills

    Science.gov (United States)

    Donald G. Hodges; Walter C. Anderson; Charles W. McMillin

    1990-01-01

    Research has demonstrated that a knowledge of internal log defects prior to sawing could improve lumber value yields significantly. This study evaluated the potential economic returns from investments in computerized tomographic (CT) scanners to detect internal defects in hardwood logs at southern sawmills. The results indicate that such investments would be profitable...

  7. Examination of Scanner Precision by Analysing Orthodontic Parameters

    OpenAIRE

    Majstorović Nemanja; Čerče Luka; Kramar Davorin; Soković Mirko; Glišić Branislav; Majstorović Vidosav; Živković Srđan

    2017-01-01

    Background: 3D modelling in orthodontics is becoming an increasingly widespread technique in practice. One of the significant questions already being asked is related to determining the precision of the scanner used for generating surfaces on a 3D model of the jaw.

  8. Examination of Scanner Precision by Analysing Orthodontic Parameters

    Directory of Open Access Journals (Sweden)

    Majstorović Nemanja

    2017-03-01

    Full Text Available Background: 3D modelling in orthodontics is becoming an increasingly widespread technique in practice. One of the significant questions already being asked is related to determining the precision of the scanner used for generating surfaces on a 3D model of the jaw.

  9. Phosphor Scanner For Imaging X-Ray Diffraction

    Science.gov (United States)

    Carter, Daniel C.; Hecht, Diana L.; Witherow, William K.

    1992-01-01

    Improved optoelectronic scanning apparatus generates digitized image of x-ray image recorded in phosphor. Scanning fiber-optic probe supplies laser light stimulating luminescence in areas of phosphor exposed to x rays. Luminescence passes through probe and fiber to integrating sphere and photomultiplier. Sensitivity and resolution exceed previously available scanners. Intended for use in x-ray crystallography, medical radiography, and molecular biology.

  10. Subchannel Analysis of Wire Wrapped SCWR Assembly

    Directory of Open Access Journals (Sweden)

    Jianqiang Shan

    2014-01-01

    Full Text Available Application of wire wrap spacers in SCWR can reduce pressure drop and obtain better mixing capability. As a consequence, the required coolant pumping power is decreased and the coolant temperature profile inside the fuel bundle is flattened which will obviously decrease the peak cladding temperature. The distributed resistance model for wire wrap was developed and implemented in ATHAS subchannel analysis code. The HPLWR wire wrapped assembly was analyzed. The results show that: (1 the assembly with wire wrap can obtain a more uniform coolant temperature profile than the grid spaced assembly, which will result in a lower peak cladding temperature; (2 the pressure drop in a wire wrapped assembly is less than that in a grid spaced assembly, which can reduce the operating power of pump effectively; (3 the wire wrap pitch has significant effect on the flow in the assembly. Smaller Hwire/Drod will result in stronger cross flow a more uniform coolant temperature profile, and also a higher pressure drop.

  11. Superconducting wires and methods of making thereof

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xingchen; Sumption, Michael D.; Peng, Xuan

    2018-03-13

    Disclosed herein are superconducting wires. The superconducting wires can comprise a metallic matrix and at least one continuous subelement embedded in the matrix. Each subelement can comprise a non-superconducting core, a superconducting layer coaxially disposed around the non-superconducting core, and a barrier layer coaxially disposed around the superconducting layer. The superconducting layer can comprise a plurality of Nb.sub.3Sn grains stabilized by metal oxide particulates disposed therein. The Nb.sub.3Sn grains can have an average grain size of from 5 nm to 90 nm (for example, from 15 nm to 30 nm). The superconducting wire can have a high-field critical current density (J.sub.c) of at least 5,000 A/mm.sup.2 at a temperature of 4.2 K in a magnetic field of 12 T. Also described are superconducting wire precursors that can be heat treated to prepare superconducting wires, as well as methods of making superconducting wires.

  12. Si Wire-Array Solar Cells

    Science.gov (United States)

    Boettcher, Shannon

    2010-03-01

    Micron-scale Si wire arrays are three-dimensional photovoltaic absorbers that enable orthogonalization of light absorption and carrier collection and hence allow for the utilization of relatively impure Si in efficient solar cell designs. The wire arrays are grown by a vapor-liquid-solid-catalyzed process on a crystalline (111) Si wafer lithographically patterned with an array of metal catalyst particles. Following growth, such arrays can be embedded in polymethyldisiloxane (PDMS) and then peeled from the template growth substrate. The result is an unusual photovoltaic material: a flexible, bendable, wafer-thickness crystalline Si absorber. In this paper I will describe: 1. the growth of high-quality Si wires with controllable doping and the evaluation of their photovoltaic energy-conversion performance using a test electrolyte that forms a rectifying conformal semiconductor-liquid contact 2. the observation of enhanced absorption in wire arrays exceeding the conventional light trapping limits for planar Si cells of equivalent material thickness and 3. single-wire and large-area solid-state Si wire-array solar cell results obtained to date with directions for future cell designs based on optical and device physics. In collaboration with Michael Kelzenberg, Morgan Putnam, Joshua Spurgeon, Daniel Turner-Evans, Emily Warren, Nathan Lewis, and Harry Atwater, California Institute of Technology.

  13. Needleless electrospinning with twisted wire spinneret

    International Nuclear Information System (INIS)

    Holopainen, Jani; Penttinen, Toni; Santala, Eero; Ritala, Mikko

    2015-01-01

    A needleless electrospinning setup named ‘Needleless Twisted Wire Electrospinning’ was developed. The polymer solution is electrospun from the surface of a twisted wire set to a high voltage and collected on a cylindrical collector around the wire. Multiple Taylor cones are simultaneously self-formed on the downward flowing solution. The system is robust and simple with no moving parts aside from the syringe pump used to transport the solution to the top of the wire. The structure and process parameters of the setup and the results on the preparation of polyvinyl pyrrolidone (PVP), hydroxyapatite (HA) and bioglass fibers with the setup are presented. PVP fiber sheets with areas of 40 × 120 cm 2 and masses up to 1.15 g were prepared. High production rates of 5.23 g h −1 and 1.40 g h −1 were achieved for PVP and HA respectively. The major limiting factor of the setup is drying of the polymer solution on the wire during the electrospinning process which will eventually force to interrupt the process for cleaning of the wire. Possible solutions to this problem and other ways to develop the setup are discussed. The presented system provides a simple way to increase the production rate and area of fiber sheet as compared with the conventional needle electrospinning. (paper)

  14. 75 FR 60480 - In the Matter of Certain Bulk Welding Wire Containers and Components Thereof and Welding Wire...

    Science.gov (United States)

    2010-09-30

    ... COMMISSION In the Matter of Certain Bulk Welding Wire Containers and Components Thereof and Welding Wire... importation, or the sale within the United States after importation of certain bulk welding wire containers, components thereof, and welding wire by reason of infringement of certain claims of United States Patent Nos...

  15. Method for calibration of an axial tomographic scanner

    International Nuclear Information System (INIS)

    Sparks, R.A.

    1977-01-01

    The method of calibrating an axial tomographic scanner including frame means having an opening therein in which an object to be examined is to be placed, source and detector means mounted on the frame means for directing one or more beams of penetrating radiation through the object from the source to the detector means, and means to rotate the scanner including the source and detector means about the object whereby a plurality of sets of data corresponding to the transmission or absorption by the object of a plurality of beams of penetrating radiation are collected; the calibration method comprising mounting calibration means supporting an adjustable centering member onto the frame means, positioning the adjustable centering member at approximately the center of rotation of the scanner, placing position-sensitive indicator means adjacent the approximately centered member, rotating the scanner and the calibration means mounted thereon at least one time and, if necessary, adjusting the positioning of the centering member until the centering member is coincident with the center of rotation of the scanner as determined by minimum deflection of the position-sensitive indicator means, rotating and translating the source and detector means and determining for each angular orientation of the frame means supporting the source and detector means the central position of each translational scan relative to the centered member and/or if a plurality of detectors are utilized with the detector means for each planar slice of the object being examined, the central position of each translational scan for each detector relative to the centered member

  16. Empolder and application of LiveWire program

    International Nuclear Information System (INIS)

    Zhang Bo; Li Jing; Wang Xiaoming

    2007-01-01

    LiveWire is a specific module of Netscape Web server to actualize CGI function; through LiveWire application program one can create dynamic web page on web site. This article introduces how to write LiveWire application code, have to compile, debug and manage LiveWire application programs, and how to apply LiveWire application program on Netscape Web server to create a dynamic web page. (authors)

  17. Wiring design for the control of electromagnetic interference (EMI)

    Science.gov (United States)

    Kopasakis, George

    1995-01-01

    Wiring design is only one important aspect of EMI control. Other important areas for EMI are: circuit design, filtering, grounding, bonding, shielding, lighting, electrostatic discharge (ESD), transient suppression, and electromagnetic pulse (EMP). Topics covered include: wire magnetic field emissions at low frequencies; wire radiated magnetic field emissions at frequencies; wire design guidelines for EMI control; wire design guidelines for EMI control; high frequency emissions from cables; and pulse frequency spectra.

  18. Defense Commissaries: Issues Related to the Sale of Electronic Scanner Data

    National Research Council Canada - National Science Library

    1998-01-01

    In response to your request that we review DeCA'S sale of scanner data and its implementation of category management, this report identifies DeCA'S total revenue from selling scanner data and compares license revenues...

  19. Study on Exploding Wire Compression for Evaluating Electrical Conductivity in Warm-Dense Diamond-Like-Carbon

    International Nuclear Information System (INIS)

    Sasaki, Toru; Takahashi, Kazumasa; Kudo, Takahiro; Kikuchi, Takashi; Aso, Tsukasa; Harada, Nob.; Fujioka, Shinsuke; Horioka, Kazuhiko

    2016-01-01

    To improve a coupling efficiency for the fast ignition scheme of the inertial confinement fusion, fast electron behaviors as a function of an electrical conductivity are required. To evaluate the electrical conductivity for low-Z materials as a diamond-like-carbon (DLC), we have proposed a concept to investigate the properties of warm dense matter (WDM) by using pulsed-power discharges. The concept of the evaluation of DLC for WDM is a shock compression driven by an exploding wire discharge with confined by a rigid capillary. The qualitatively evaluation of the electrical conductivity for the WDM DLC requires a small electrical conductivity of the exploding wire. To analyze the electrical conductivity of exploding wire, we have demonstrated an exploding wire discharge in water for gold. The results indicated that the electrical conductivity of WDM gold for 5000 K of temperature has an insulator regime. It means that the shock compression driven by the exploding wire discharge with confined by the rigid capillary is applied for the evaluation of electrical conductivity for WDM DLC. (paper)

  20. Mixed and dynamic response of hot wires and cold wires and measurements of turbulence statistics

    DEFF Research Database (Denmark)

    Larsen, Søren Ejling; Højstrup, Jørgen; Fairall, C. W.

    1986-01-01

    Hot wires respond to temperature as well as to velocity, whereas cold wires respond to velocity as well as to temperature. The static and dynamic response characteristics are summarized and it is shown that the frequency transfer functions for the four different responses in general are different...

  1. Modeling and simulation of the fluid flow in wire electrochemical machining with rotating tool (wire ECM)

    Science.gov (United States)

    Klocke, F.; Herrig, T.; Zeis, M.; Klink, A.

    2017-10-01

    Combining the working principle of electrochemical machining (ECM) with a universal rotating tool, like a wire, could manage lots of challenges of the classical ECM sinking process. Such a wire-ECM process could be able to machine flexible and efficient 2.5-dimensional geometries like fir tree slots in turbine discs. Nowadays, established manufacturing technologies for slotting turbine discs are broaching and wire electrical discharge machining (wire EDM). Nevertheless, high requirements on surface integrity of turbine parts need cost intensive process development and - in case of wire-EDM - trim cuts to reduce the heat affected rim zone. Due to the process specific advantages, ECM is an attractive alternative manufacturing technology and is getting more and more relevant for sinking applications within the last few years. But ECM is also opposed with high costs for process development and complex electrolyte flow devices. In the past, few studies dealt with the development of a wire ECM process to meet these challenges. However, previous concepts of wire ECM were only suitable for micro machining applications. Due to insufficient flushing concepts the application of the process for machining macro geometries failed. Therefore, this paper presents the modeling and simulation of a new flushing approach for process assessment. The suitability of a rotating structured wire electrode in combination with an axial flushing for electrodes with high aspect ratios is investigated and discussed.

  2. STRS SpaceWire FPGA Module

    Science.gov (United States)

    Lux, James P.; Taylor, Gregory H.; Lang, Minh; Stern, Ryan A.

    2011-01-01

    An FPGA module leverages the previous work from Goddard Space Flight Center (GSFC) relating to NASA s Space Telecommunications Radio System (STRS) project. The STRS SpaceWire FPGA Module is written in the Verilog Register Transfer Level (RTL) language, and it encapsulates an unmodified GSFC core (which is written in VHDL). The module has the necessary inputs/outputs (I/Os) and parameters to integrate seamlessly with the SPARC I/O FPGA Interface module (also developed for the STRS operating environment, OE). Software running on the SPARC processor can access the configuration and status registers within the SpaceWire module. This allows software to control and monitor the SpaceWire functions, but it is also used to give software direct access to what is transmitted and received through the link. SpaceWire data characters can be sent/received through the software interface, as well as through the dedicated interface on the GSFC core. Similarly, SpaceWire time codes can be sent/received through the software interface or through a dedicated interface on the core. This innovation is designed for plug-and-play integration in the STRS OE. The SpaceWire module simplifies the interfaces to the GSFC core, and synchronizes all I/O to a single clock. An interrupt output (with optional masking) identifies time-sensitive events within the module. Test modes were added to allow internal loopback of the SpaceWire link and internal loopback of the client-side data interface.

  3. Digital Data Matrix Scanner Developnent At Marshall Space Flight Center

    Science.gov (United States)

    2004-01-01

    Research at NASA's Marshall Space Flight Center has resulted in a system for reading hidden identification codes using a hand-held magnetic scanner. It's an invention that could help businesses improve inventory management, enhance safety, improve security, and aid in recall efforts if defects are discovered. Two-dimensional Data Matrix symbols consisting of letters and numbers permanently etched on items for identification and resembling a small checkerboard pattern are more efficient and reliable than traditional bar codes, and can store up to 100 times more information. A team led by Fred Schramm of the Marshall Center's Technology Transfer Department, in partnership with PRI,Torrance, California, has developed a hand-held device that can read this special type of coded symbols, even if covered by up to six layers of paint. Before this new technology was available, matrix symbols were read with optical scanners, and only if the codes were visible. This latest improvement in digital Data Matrix technologies offers greater flexibility for businesses and industries already using the marking system. Paint, inks, and pastes containing magnetic properties are applied in matrix symbol patterns to objects with two-dimensional codes, and the codes are read by a magnetic scanner, even after being covered with paint or other coatings. The ability to read hidden matrix symbols promises a wide range of benefits in a number of fields, including airlines, electronics, healthcare, and the automotive industry. Many industries would like to hide information on a part, so it can be read only by the party who put it there. For instance, the automotive industry uses direct parts marking for inventory control, but for aesthetic purposes the marks often need to be invisible. Symbols have been applied to a variety of materials, including metal, plastic, glass, paper, fabric and foam, on everything from electronic parts to pharmaceuticals to livestock. The portability of the hand

  4. A dedicated tool for PET scanner simulations using FLUKA

    International Nuclear Information System (INIS)

    Ortega, P.G.; Boehlen, T.T.; Cerutti, F.; Chin, M.P.W.; Ferrari, A.; Mancini, C.; Vlachoudis, V.; Mairani, A.; Sala, Paola R.

    2013-06-01

    Positron emission tomography (PET) is a well-established medical imaging technique. It is based on the detection of pairs of annihilation gamma rays from a beta+-emitting radionuclide, usually inoculated in the body via a biologically active molecule. Apart from its wide-spread use for clinical diagnosis, new applications are proposed. This includes notably the usage of PET for treatment monitoring of radiation therapy with protons and ions. PET is currently the only available technique for non-invasive monitoring of ion beam dose delivery, which was tested in several clinical pilot studies. For hadrontherapy, the distribution of positron emitters, produced by the ion beam, can be analyzed to verify the correct treatment delivery. The adaptation of previous PET scanners to new environments and the necessity of more precise diagnostics by better image quality triggered the development of new PET scanner designs. The use of Monte Carlo (MC) codes is essential in the early stages of the scanner design to simulate the transport of particles and nuclear interactions from therapeutic ion beams or radioisotopes and to predict radiation fields in tissues and radiation emerging from the patient. In particular, range verification using PET is based on the comparison of detected and simulated activity distributions. The accuracy of the MC code for the relevant physics processes is obviously essential for such applications. In this work we present new developments of the physics models with importance for PET monitoring and integrated tools for PET scanner simulations for FLUKA, a fully-integrated MC particle-transport code, which is widely used for an extended range of applications (accelerator shielding, detector and target design, calorimetry, activation, dosimetry, medical physics, radiobiology, ...). The developed tools include a PET scanner geometry builder and a dedicated scoring routine for coincident event determination. The geometry builder allows the efficient

  5. A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

    Energy Technology Data Exchange (ETDEWEB)

    Yudaya Sivathanu; Jongmook Lim; Vinoo Narayanan; Seonghyeon Park

    2005-12-07

    The objective of this project is to design, fabricate and demonstrate a cost effective, multi-spectral scanner for natural gas leak detection in transmission and distribution pipelines. During the first year of the project, a laboratory version of the multi-spectral scanner was designed, fabricated, and tested at EnUrga Inc. The multi-spectral scanner was also evaluated using a blind Department of Energy study at the Rocky Mountain Oilfield Testing Center. The performance of the scanner was inconsistent during the blind study. However, most of the leaks were outside the view of the multi-spectral scanner that was developed during the first year of the project. Therefore, a definite evaluation of the capability of the scanner was not obtained. Despite the results, sufficient number of plumes was detected fully confirming the feasibility of the multi-spectral scanner. During the second year, the optical design of the scanner was changed to improve the sensitivity of the system. Laboratory tests show that the system can reliably detect small leaks (20 SCFH) at 30 to 50 feet. A prototype scanner was built and evaluated during the second year of the project. Only laboratory evaluations were completed during the second year. The laboratory evaluations show the feasibility of using the scanner to determine natural gas pipeline leaks. Further field evaluations and optimization of the scanner are required before commercialization of the scanner can be initiated.

  6. Strength of stainless steel surgical wire in various fixation modes.

    Science.gov (United States)

    Schultz, R S; Boger, J W; Dunn, H K

    1985-09-01

    Although wire is a commonly used fixation device in orthopedics, little is known about the effects of fastening methods and configurations on the strength of wiring systems. Three sizes of stainless steel surgical wire were tested in noncyclic tensile loading. Load failure levels increased with enlarging wire diameter. Fastening twists were stronger than knots or the ASIF bend technique. The failure mode for twists was untwisting. More than two twists gave no additional strength to the system. Two commercial wire tightening devices gave stronger and more reproducible twists than did ordinary pliers. The addition of a tension equalizing loop opposite the fastening loop weakened the wire system by 10%-15%. The combination of two single wire loops was stronger than a continuous double loop of wire. The results from this study are intended to help the orthopedic surgeon optimize the use of wire.

  7. Development of a clear sub-millimeter small animal PET scanner by reducing the influence of the non-collinearity effect

    Science.gov (United States)

    Bolwin, K.; Vernekohl, D.; Lühder, J.; Czekalla, B.; Wessels, J. P.; Schäfers, K. P.

    2017-03-01

    Small animal PET plays a major role in studying molecular processes in vivo. However, the spatial resolution of small animal PET is limited by physical effects like positron range, photon non-collinearity, and object scattering. The aim of this project was to minimize the influence of the non-collinearity effect by reducing the distance between the coincidence detectors leading to an improved spatial resolution. A multi-wire proportional chamber-based high-resolution PET scanner (quadHIDAC) was used, offering a spatial resolution of nearly 1 mm FWHM. By removing two opposite detector banks of the 4-detector-setup, the inner distance between the two remaining detector plates could be reduced from 180 mm to 40 mm. List mode acquisitions of a small point source (22Na) experiment were performed, images were reconstructed (0.25 mm voxel size) using a one-pass list-mode EM algorithm and the FWHM in the radial, tangential, and axial directions was calculated. In addition, a Jaszczak phantom (hole sizes of 0.7 up to 1.2 mm) was acquired with both scanners. The prototype high-resolution PET scanner showed improved spatial resolution in radial (0.9 mm FWHM), tangential (0.9 mm FWHM), and axial (0.8 mm FWHM) direction compared to the quadHIDAC scanner (1.x mm, 1.x mm, 1.x mm), respectively offering clear sub-millimeter imaging. Blurring effects due to photon non-collinearity could be reduced by minimizing the detector distance.

  8. Integrated Electrical Wire Insulation Repair System

    Science.gov (United States)

    Williams, Martha; Jolley, Scott; Gibson, Tracy; Parks, Steven

    2013-01-01

    An integrated system tool will allow a technician to easily and quickly repair damaged high-performance electrical wire insulation in the field. Low-melt polyimides have been developed that can be processed into thin films that work well in the repair of damaged polyimide or fluoropolymer insulated electrical wiring. Such thin films can be used in wire insulation repairs by affixing a film of this low-melt polyimide to the damaged wire, and heating the film to effect melting, flow, and cure of the film. The resulting repair is robust, lightweight, and small in volume. The heating of this repair film is accomplished with the use of a common electrical soldering tool that has been modified with a special head or tip that can accommodate the size of wire being repaired. This repair method can furthermore be simplified for the repair technician by providing replaceable or disposable soldering tool heads that have repair film already "loaded" and ready for use. The soldering tool heating device can also be equipped with a battery power supply that will allow its use in areas where plug-in current is not available

  9. EVALUATION OF INDUCTANCE WITH ELECTRICAL WIRES

    Directory of Open Access Journals (Sweden)

    V. Kudry

    2016-08-01

    Full Text Available In this paper proved the possibility of developing passive electronic inductive elements based replace metal wire that is wound inductor, the wire is made of electret. The relative permeability of the electret S  10 000, several orders of magnitude greater than the permeability of conventional insulation materials, i < 10, resulting current in the wire acquires properties bias current. The essence of innovation is to replace the source of of magnetic induction flow that pervades the core of the coil. According to the theory of electrodynamics, current bias, in contrast to conduction current, generated no movement of charge along the wire, but the change of the charge in the local volume.Equivalence bias current and conduction current is manifested in the possibility of forming a magnetic field. The flow through magnetic induction coil core regardless of the current it generates, creates voltage at its ends.The paper also shows the numeric characteristics that determine the effective frequency range, specified the reason why electric a wire with і < 10 can not generate magnetic flux through the core and serve as a passive reactive component.

  10. Percutaneous tension band wiring for patellar fractures.

    Science.gov (United States)

    Rathi, Akhilesh; Swamy, M K S; Prasantha, I; Consul, Ashu; Bansal, Abhishek; Bahl, Vibhu

    2012-08-01

    To evaluate outcome of percutaneous tension band wiring for transverse fractures of the patella. 16 men and 7 women aged 27 to 65 (mean, 40) years underwent percutaneous tension band wiring for transverse fractures of the patella with a displacement of >3 mm. Pain, operating time, mobility, functional score, and complications were evaluated. 20 patients underwent successful percutaneous tension band wiring. The remaining 3 patients in whom closed reduction failed underwent open reduction and tension band wiring. The mean operating time was 46 (range, 28-62) minutes. The mean follow-up period was 20 (range, 15-30) months. At the latest follow-up, all patients had regained full extension. The objective score was excellent in 20 patients and good in 3, whereas the subjective score was excellent in 17, good in 5, and fair in one. All patients had radiological union at week 8. One patient had patellofemoral arthritis (secondary to a postoperative articular step). Two patients developed superficial infections, which resolved after antibiotic therapy. Mean thigh muscle wasting was 0.7 (range, 0.4-1) cm. Three patients encountered hardware problems (impingement/irritation of the skin over the knee) necessitating implant removal. Percutaneous tension band wiring is a viable option for transverse fractures of the patella.

  11. The airborne infrared scanner as a geophysical research tool

    Science.gov (United States)

    Friedman, Jules D.

    1970-01-01

    The infrared scanner is proving to be an effective anomaly-mapping tool, albeit one which depicts surface emission directly and heat mass transfer from depths only indirectly and at a threshold level 50 to 100 times the normal conductive heat flow of the earth. Moreover, successive terrain observations are affected by time-dependent variables such as the diurnal and seasonal warming and cooling cycle of a point on the earth's surface. In planning precise air borne surveys of radiant flux from the earth's surface, account must be taken of background noise created by variations in micrometeorological factors and emissivity of surface materials, as well as the diurnal temperature cycle. The effect of the diurnal cycle may be minimized by planning predawn aerial surveys. In fact, the diurnal change is very small for most water bodies and the emissivity factor for water (e) =~ 1 so a minimum background noise is characteristic of scanner records of calm water surfaces.

  12. Robust Object Segmentation Using a Multi-Layer Laser Scanner

    Science.gov (United States)

    Kim, Beomseong; Choi, Baehoon; Yoo, Minkyun; Kim, Hyunju; Kim, Euntai

    2014-01-01

    The major problem in an advanced driver assistance system (ADAS) is the proper use of sensor measurements and recognition of the surrounding environment. To this end, there are several types of sensors to consider, one of which is the laser scanner. In this paper, we propose a method to segment the measurement of the surrounding environment as obtained by a multi-layer laser scanner. In the segmentation, a full set of measurements is decomposed into several segments, each representing a single object. Sometimes a ghost is detected due to the ground or fog, and the ghost has to be eliminated to ensure the stability of the system. The proposed method is implemented on a real vehicle, and its performance is tested in a real-world environment. The experiments show that the proposed method demonstrates good performance in many real-life situations. PMID:25356645

  13. Dental models made with an intraoral scanner: a validation study.

    Science.gov (United States)

    Cuperus, Anne Margreet R; Harms, Marit C; Rangel, Frits A; Bronkhorst, Ewald M; Schols, Jan G J H; Breuning, K Hero

    2012-09-01

    Our objectives were to determine the validity and reproducibility of measurements on stereolithographic models and 3-dimensional digital dental models made with an intraoral scanner. Ten dry human skulls were scanned; from the scans, stereolithographic models and digital models were made. Two observers measured transversal distances, mesiodistal tooth widths, and arch segments on the skulls and the stereolithographic and digital models. All measurements were repeated 4 times. Arch length discrepancy and tooth size discrepancy were calculated. Statistical analysis was performed by using paired t tests. For the measurements on the stereolithographic and digital models, statistically significant differences were found. However, these differences were considered to be clinically insignificant. Digital models had fewer statistically significant differences and generally the smallest duplicate measurement errors compared with the stereolithographic models. Stereolithographic and digital models made with an intraoral scanner are a valid and reproducible method for measuring distances in a dentition. Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  14. Object 3D surface reconstruction approach using portable laser scanner

    Science.gov (United States)

    Xu, Ning; Zhang, Wei; Zhu, Liye; Li, Changqing; Wang, Shifeng

    2017-06-01

    The environment perception plays the key role for a robot system. The 3D surface of the objects can provide essential information for the robot to recognize objects. This paper present an approach to reconstruct objects' 3D surfaces using a portable laser scanner we designed which consists of a single-layer laser scanner, an encoder, a motor, power supply and mechanical components. The captured point cloud data is processed to remove the discrete points, denoise filtering, stitching and registration. Then the triangular mesh generation of point cloud is accomplished by using Gaussian bilateral filtering, ICP real-time registration and greedy triangle projection algorithm. The experiment result shows the feasibility of the device designed and the algorithm proposed.

  15. Monolithically integrated glass microlens scanner using a thermal reflow process

    International Nuclear Information System (INIS)

    Yoo, Sunghyun; Ha, Joon-Geun; Jin, Joo-Young; Kim, Yong-Kweon; Ji, Chang-Hyeon

    2013-01-01

    A monolithically integrated glass microlens optical scanner is presented. A new wafer-level fabrication approach addresses the issue of microlens integration and alignment in conventional microlens integrated devices. A through-silicon plano-convex glass microlens has been fabricated on a silicon substrate prior to the formation of an integrated microlens actuator, realized through two thermal reflow processes at 850 °C. A lateral comb drive is adapted to demonstrate the glass microlens scanner. The 800 µm diameter microlens was laterally shifted up to ±51.6 µm when an ac voltage of 28.5 V in amplitude was applied at a resonant frequency of 1.749 kHz at atmospheric pressure. The optical scanning angle of ±2.0° has been obtained with the fabricated device. (paper)

  16. Robust Object Segmentation Using a Multi-Layer Laser Scanner

    Directory of Open Access Journals (Sweden)

    Beomseong Kim

    2014-10-01

    Full Text Available The major problem in an advanced driver assistance system (ADAS is the proper use of sensor measurements and recognition of the surrounding environment. To this end, there are several types of sensors to consider, one of which is the laser scanner. In this paper, we propose a method to segment the measurement of the surrounding environment as obtained by a multi-layer laser scanner. In the segmentation, a full set of measurements is decomposed into several segments, each representing a single object. Sometimes a ghost is detected due to the ground or fog, and the ghost has to be eliminated to ensure the stability of the system. The proposed method is implemented on a real vehicle, and its performance is tested in a real-world environment. The experiments show that the proposed method demonstrates good performance in many real-life situations.

  17. Effect of Size on Tensile Strength of Fine Polycrystalline Nickel Wires

    National Research Council Canada - National Science Library

    Rubenstein, Lester

    1966-01-01

    .... The tensile strength of recrystallized wires was diameter independent. The proportional limit stress of recrystallized wires was inversely related to power functions of wire diameter and grain size...

  18. POINT CLOUD ANALYSIS FOR UAV-BORNE LASER SCANNING WITH HORIZONTALLY AND VERTICALLY ORIENTED LINE SCANNERS – CONCEPT AND FIRST RESULTS

    Directory of Open Access Journals (Sweden)

    M. Weinmann

    2017-08-01

    Full Text Available In this paper, we focus on UAV-borne laser scanning with the objective of densely sampling object surfaces in the local surrounding of the UAV. In this regard, using a line scanner which scans along the vertical direction and perpendicular to the flight direction results in a point cloud with low point density if the UAV moves fast. Using a line scanner which scans along the horizontal direction only delivers data corresponding to the altitude of the UAV and thus a low scene coverage. For these reasons, we present a concept and a system for UAV-borne laser scanning using multiple line scanners. Our system consists of a quadcopter equipped with horizontally and vertically oriented line scanners. We demonstrate the capabilities of our system by presenting first results obtained for a flight within an outdoor scene. Thereby, we use a downsampling of the original point cloud and different neighborhood types to extract fundamental geometric features which in turn can be used for scene interpretation with respect to linear, planar or volumetric structures.

  19. Experimental characterization of the Clear-PEM scanner spectrometric performance

    Science.gov (United States)

    Bugalho, R.; Carriço, B.; Ferreira, C. S.; Frade, M.; Ferreira, M.; Moura, R.; Ortigão, C.; Pinheiro, J. F.; Rodrigues, P.; Rolo, I.; Silva, J. C.; Trindade, A.; Varela, J.

    2009-10-01

    In the framework of the Clear-PEM project for the construction of a high-resolution and high-specificity scanner for breast cancer imaging, a Positron Emission Mammography tomograph has been developed and installed at the Instituto Português de Oncologia do Porto hospital. The Clear-PEM scanner is mainly composed by two planar detector heads attached to a robotic arm, trigger/data acquisition electronics system and computing servers. The detector heads hold crystal matrices built from 2 × 2 × 20 mm3 LYSO:Ce crystals readout by Hamamatsu S8550 APD arrays. The APDs are optically coupled to both ends of the 6144 crystals in order to extract the DOI information for each detected event. Each one of 12288 APD's pixels is read and controlled by Application Specific Integrated Circuits water-cooled by an external cooling unit. The Clear-PEM frontend boards innovative design results in a unprecedented integration of the crystal matrices, APDs and ASICs, making Clear-PEM the PET scanner with the highest number of APD pixels ever integrated so far. In this paper, the scanner's main technical characteristics, calibration strategies and the first spectrometric performance evaluation in a clinical environment are presented. The first commissioning results show 99.7% active channels, which, after calibration, have inter-pixel and absolute gain distributions with dispersions of, respectively, 12.2% and 15.3%, demonstrating that despite the large number of channels, the system is uniform. The mean energy resolution at 511 keV is of 15.9%, with a 8.8% dispersion, and the mean CDOI-1 is 5.9%/mm, with a 7.8% dispersion. The coincidence time resolution, at 511 keV, for a energy window between 400 and 600 keV, is 5.2 ns FWHM.

  20. Automatic inventory of components by laser 3D scanner

    International Nuclear Information System (INIS)

    Rodriguez Garcia, R.; Munoz Prieto, C.; Sarti Fernandez, F.

    2014-01-01

    One of the existing needs in nuclear decommissioning projects is to provide an inventory of components to be dismantled, which is available from its spatial location and elements that exist in your environment. The Laser scanner technology is a system of data acquisition that allows 3D models composed of millions of points, it's models with pinpoint accuracy and are available in a very short space of time. (Author)

  1. Kalmtool used for laser scanner aided navigation in orchard

    DEFF Research Database (Denmark)

    Mogensen, Lars Valdemar; Hansen, Søren; Andersen, Jens Christian

    2009-01-01

    This paper concerns localisation of an autonomous tractor in an orchard environment, with the purpose of designing a localisation solution to be compared with GPS. The localisation is based on an estimate found by an extended Kalman filter, which fuses measurements from encoders and gyro with row...... measurements provided by a laser scanner. Kalmtool is used as a toolbox for developing the localisation algorithm. The result shows that the toolbox can be used successfully for dealing with localisation and sensor fusion....

  2. Concrete hardened characterization using table scanner and microtomography computed

    International Nuclear Information System (INIS)

    Wilson, R.E.; Pessoa, J.R.; Assis, J.T. de; Dominguez, D.S.; Dias, L.A.; Santana, M. R.

    2016-01-01

    This paper proposes the use of image processing technologies to analyze hardened concrete samples obtained from table scanner and micro tomography. Techniques will be used to obtain numerical data on the distribution and geometry of aggregates and pores of the concrete, as well as their relative position. It is expected that the data obtained can produce information on the research of concrete pathologies such as AAR, and the freeze / thaw process. (author)

  3. Whole body x-ray CT scanner, TCT-900S

    International Nuclear Information System (INIS)

    Mori, Issei; Saito, Kiyoto; Asahina, Kiyotaka

    1987-01-01

    The fundamental parameters of an X-ray CT (computed tomography) scanner are temporal, spatial, and density resolution. Research projects to improve these parameters had reached a standstill until recently. Toshiba has achieved a breakthrough with the development of a new CT system, the TCT-900S, which incorporates a new scanning configuration and several technological improvements. The TCT-900S is already in clinical use in many hospitals nationwide, and new diagnostic applications are being explored. (author)

  4. Experimental characterization of the Clear-PEM scanner spectrometric performance

    Energy Technology Data Exchange (ETDEWEB)

    Bugalho, R; Carrico, B; Ferreira, C S; Frade, M; Ferreira, M; Moura, R; Ortigao, C; Pinheiro, J F; Rodrigues, P; Rolo, I; Silva, J C; Trindade, A; Varela, J [Laboratorio de Instrumentacao e Fisica Experimental de Particulas (LIP), Av. Elias Garcia 14-1, 1000-149 Lisboa (Portugal)], E-mail: frade@lip.pt

    2009-10-15

    In the framework of the Clear-PEM project for the construction of a high-resolution and high-specificity scanner for breast cancer imaging, a Positron Emission Mammography tomograph has been developed and installed at the Instituto Portugues de Oncologia do Porto hospital. The Clear-PEM scanner is mainly composed by two planar detector heads attached to a robotic arm, trigger/data acquisition electronics system and computing servers. The detector heads hold crystal matrices built from 2 x 2 x 20 mm{sup 3} LYSO:Ce crystals readout by Hamamatsu S8550 APD arrays. The APDs are optically coupled to both ends of the 6144 crystals in order to extract the DOI information for each detected event. Each one of 12288 APD's pixels is read and controlled by Application Specific Integrated Circuits water-cooled by an external cooling unit. The Clear-PEM frontend boards innovative design results in a unprecedented integration of the crystal matrices, APDs and ASICs, making Clear-PEM the PET scanner with the highest number of APD pixels ever integrated so far. In this paper, the scanner's main technical characteristics, calibration strategies and the first spectrometric performance evaluation in a clinical environment are presented. The first commissioning results show 99.7% active channels, which, after calibration, have inter-pixel and absolute gain distributions with dispersions of, respectively, 12.2% and 15.3%, demonstrating that despite the large number of channels, the system is uniform. The mean energy resolution at 511 keV is of 15.9%, with a 8.8% dispersion, and the mean C{sub DOI}{sup -1} is 5.9%/mm, with a 7.8% dispersion. The coincidence time resolution, at 511 keV, for a energy window between 400 and 600 keV, is 5.2 ns FWHM.

  5. Whole brain CT perfusion on a 320-slice CT scanner

    Directory of Open Access Journals (Sweden)

    Jai Jai Shiva Shankar

    2011-01-01

    Full Text Available Computed tomography perfusion (CTP has been criticized for limited brain coverage. This may result in inadequate coverage of the lesion, inadequate arterial input function, or omission of the lesion within the target perfusion volume. The availability of 320-slice CT scanners offers whole brain coverage. This minimizes the chances of misregistration of lesions regardless of location, and makes the selection of the arterial input function easy. We present different clinical scenarios in which whole brain CTP is especially useful.

  6. Attitudes des prescripteurs de scanner en matiere de radioprotection ...

    African Journals Online (AJOL)

    Objectif: Evaluer les attitudes des prescripteurs de scanner en matière de radioprotection des patients à Lomé au Togo. Méthodologie: Etude transversale descriptive réalisée du 1er Avril au 30 Juin 2015 dans les centres hospitaliers universitaires, le centre hospitalier régional, les cabinets médicaux et les cliniques privées ...

  7. Magnetic wires in MEMS and bio-medical applications

    International Nuclear Information System (INIS)

    Barbic, Mladen

    2002-01-01

    Magnetic wires of appropriate design have special features making them useful to micro-electromechanical systems and bio-medical applications. Several applications that exploit the properties of magnetic wires are reviewed including: (a) a magnetic micro-manipulation technique that utilizes integrated micro-coils and magnetic micro-wires for localized positioning of micron-sized magnetic objects, (b) integrated micro-coil/micro-wire system operating as a micro-fluidic micro-motor, (c) mechanical tweezers using magneto-static interaction between two magnetic micro-wires, and (d) ultra-high gradient magnetic separation system based on porous membranes partially filled with magnetic wires

  8. Cone beam optical computed tomography for gel dosimetry I: scanner characterization

    Energy Technology Data Exchange (ETDEWEB)

    Olding, Tim; Holmes, Oliver; Schreiner, L John, E-mail: tim.olding@krcc.on.c [Department of Physics, Queen' s University, Kingston, ON, K7L 3N6 (Canada)

    2010-05-21

    The ongoing development of easily accessible, fast optical readout tools promises to remove one of the barriers to acceptance of gel dosimetry as a viable tool in cancer clinics. This paper describes the characterization of a number of basic properties of the Vista(TM) cone beam CCD-based optical scanner, which can obtain high resolution reconstructed data in less than 20 min total imaging and reconstruction time. The suitability of a filtered back projection cone beam reconstruction algorithm is established for optically absorbing dosimeters using this scanner configuration. The system was then shown to be capable of imaging an optically absorbing media-filled 1 L polyethylene terephthalate (PETE) jar dosimeter to a reconstructed voxel resolution of 0.5 x 0.5 x 0.5 mm{sup 3}. At this resolution, more than 60% of the imaged volume in the dosimeter exhibits minimal spatial distortion, a measurement accuracy of 3-4% and the mean to standard deviation signal-to-noise ratio greater than 100 over an optical absorption range of 0.06-0.18 cm{sup -1}. An inter-day scan precision of 1% was demonstrated near the upper end of this range. Absorption measurements show evidence of stray light perturbation causing artifacts in the data, which if better managed would improve the accuracy of optical readout. Cone beam optical attenuation measurements of scattering dosimeters, on the other hand, are nonlinearly affected by angled scatter stray light. Scatter perturbation leads to significant cupping artifacts and other inaccuracies that greatly limit the readout of scattering polymer gel dosimeters with cone beam optical CT.

  9. A comparison of a 'J' wire and a straight wire in successful antegrade cannulation of the superficial femoral artery

    International Nuclear Information System (INIS)

    Gay, D.A.T.; Edwards, A.J.; Puckett, M.A.; Roobottom, C.A.

    2005-01-01

    AIMS: To evaluate the success of two different types of wire in common use in their ability to successfully cannulate the superficial femoral artery (SFA) using antegrade puncture. METHODS: 50 consecutive patients in whom antegrade infra-inguinal intervention was planned, underwent common femoral arterial puncture and then cannulation with either a standard 3 mm 'J' wire or a floppy tipped straight wire (William Cook--Europe). The frequency with which each type of wire entered the SFA or profunda femoris artery without image guidance was recorded. Further analysis was also made of the success of manipulation of the wire into the SFA following profunda cannulation and the use of alternative guide wires. RESULTS: In 19 out of 25 (76%) patients the 'J' wire correctly entered the SFA without image guidance. Only 5 out of 25 (25%) of straight wires entered the SFA with the initial pass (p<0.0001). Following further manipulation with the same wire all except 1 'J' wire was successfully negotiated into the SFA. The same was true for only 9 of the remaining straight wires with 11 patients requiring an alternative guide wire. CONCLUSIONS: When performing antegrade cannulation of the SFA a 'J' wire is more likely to be successful than a straight guide wire

  10. Portable wide-field hand-held NIR scanner

    Science.gov (United States)

    Jung, Young-Jin; Roman, Manuela; Carrasquilla, Jennifer; Erickson, Sarah J.; Godavarty, Anuradha

    2013-03-01

    Near-infrared (NIR) optical imaging modality is one of the widely used medical imaging techniques for breast cancer imaging, functional brain mapping, and many other applications. However, conventional NIR imaging systems are bulky and expensive, thereby limiting their accelerated clinical translation. Herein a new compact (6 × 7 × 12 cm3), cost-effective, and wide-field NIR scanner has been developed towards contact as well as no-contact based real-time imaging in both reflectance and transmission mode. The scanner mainly consists of an NIR source light (between 700- 900 nm), an NIR sensitive CCD camera, and a custom-developed image acquisition and processing software to image an area of 12 cm2. Phantom experiments have been conducted to estimate the feasibility of diffuse optical imaging by using Indian-Ink as absorption-based contrast agents. As a result, the developed NIR system measured the light intensity change in absorption-contrasted target up to 4 cm depth under transillumination mode. Preliminary in-vivo studies demonstrated the feasibility of real-time monitoring of blood flow changes. Currently, extensive in-vivo studies are carried out using the ultra-portable NIR scanner in order to assess the potential of the imager towards breast imaging..

  11. Determining the surface roughness coefficient by 3D Scanner

    Directory of Open Access Journals (Sweden)

    Karmen Fifer Bizjak

    2010-12-01

    Full Text Available Currently, several test methods can be used in the laboratory to determine the roughness of rock joint surfaces.However, true roughness can be distorted and underestimated by the differences in the sampling interval of themeasurement methods. Thus, these measurement methods produce a dead zone and distorted roughness profiles.In this paper a new rock joint surface roughness measurement method is presented, with the use of a camera-typethree-dimensional (3D scanner as an alternative to current methods. For this study, the surfaces of ten samples oftuff were digitized by means of a 3D scanner, and the results were compared with the corresponding Rock JointCoefficient (JRC values. Up until now such 3D scanner have been mostly used in the automotive industry, whereastheir use for comparison with obtained JRC coefficient values in rock mechanics is presented here for the first time.The proposed new method is a faster, more precise and more accurate than other existing test methods, and is apromising technique for use in this area of study in the future.

  12. Quality assurance of computed tomography scanner beams in diagnostic radiology

    International Nuclear Information System (INIS)

    Lindskoug, B.A.

    1989-01-01

    The number of computed tomography (CT) scanners in diagnostic radiology is increasing, to the extent that they are now found in relatively small hospitals. These hospitals do not have local physicists available and so methods must be developed to allow quality assurance to be carried out at distant laboratories. Several different types of solid water phantoms are available with various built-in test objects that may supply sufficient information about the many parameters that must be checked. The dose distributions, however, are usually not so well considered, although the connection between image quality and absorbed dose must be known for optimal use of a CT scanner. By introducing thermoluminescent dosemeters (TLDs) into a commercial phantom (RMI), it was possible to measure the absorbed dose profile and the line integral of the absorbed dose across the slit. The computer-guided readout of the TLDs gives the absorbed dose, the average dose and half maximum width, absorbed dose curve, and also the line integral of the peak. The only modification of the phantom was five holes, drilled at strategic positions, that did not influence the built-in test objects. This single measurement provides an appropriate monthly quality assurance check of the CT scanner with little extra effort. (author)

  13. Visual stimulus presentation using fiber optics in the MRI scanner.

    Science.gov (United States)

    Huang, Ruey-Song; Sereno, Martin I

    2008-03-30

    Imaging the neural basis of visuomotor actions using fMRI is a topic of increasing interest in the field of cognitive neuroscience. One challenge is to present realistic three-dimensional (3-D) stimuli in the subject's peripersonal space inside the MRI scanner. The stimulus generating apparatus must be compatible with strong magnetic fields and must not interfere with image acquisition. Virtual 3-D stimuli can be generated with a stereo image pair projected onto screens or via binocular goggles. Here, we describe designs and implementations for automatically presenting physical 3-D stimuli (point-light targets) in peripersonal and near-face space using fiber optics in the MRI scanner. The feasibility of fiber-optic based displays was demonstrated in two experiments. The first presented a point-light array along a slanted surface near the body, and the second presented multiple point-light targets around the face. Stimuli were presented using phase-encoded paradigms in both experiments. The results suggest that fiber-optic based displays can be a complementary approach for visual stimulus presentation in the MRI scanner.

  14. Erosion can't hide from laser scanner

    International Nuclear Information System (INIS)

    Konstant, D.A.

    1991-01-01

    Particles of topsoil blown by wind will bounce along the soil surface and finally escape a field, leaving it less able to support crops. Water will wash away valuable topsoil and nutrients. And how rough the soil surface is influences whether the soil will erode. Until now, soil scientists have had no suitable technique to measure soil roughness - or microtopography - on the small scale. ARS soil scientists Joe M. Bradford and Chi-hua Huang, of the National Soil Erosion Research Laboratory in West Lafayette, Indiana, have developed a portable scanner that can. It measures the tiny ridges left in the soil by tilling or clods of soil particles that clump together naturally. What does the scanner do? It measures soil elevation by shining a low-power laser beam onto the surface and detecting the position of the laser spot reflected from the soil with a 35-mm camera. In place of film, the scanner camera uses electronic circuitry somewhat similar to that in a video camera to transmit the spot's position to a small computer about 30,000 times a minute. The laser and camera are mounted on the frame of a motor-driven carriage. The computer controls the carriage movement. At the end of a scan, a microtopographic map is stored in the computer. Scientists can analyze it immediately and can compare it to previous maps to see whether erosion has occurred

  15. Advanced optical 3D scanners using DMD technology

    Science.gov (United States)

    Muenstermann, P.; Godding, R.; Hermstein, M.

    2017-02-01

    Optical 3D measurement techniques are state-of-the-art for highly precise, non-contact surface scanners - not only in industrial development, but also in near-production and even in-line configurations. The need for automated systems with very high accuracy and clear implementation of national precision standards is growing extremely due to expanding international quality guidelines, increasing production transparency and new concepts related to the demands of the fourth industrial revolution. The presentation gives an overview about the present technical concepts for optical 3D scanners and their benefit for customers and various different applications - not only in quality control, but also in design centers or in medical applications. The advantages of DMD-based systems will be discussed and compared to other approaches. Looking at today's 3D scanner market, there is a confusing amount of solutions varying from lowprice solutions to high end systems. Many of them are linked to a very special target group or to special applications. The article will clarify the differences of the approaches and will discuss some key features which are necessary to render optical measurement systems suitable for industrial environments. The paper will be completed by examples for DMDbased systems, e. g. RGB true-color systems with very high accuracy like the StereoScan neo of AICON 3D Systems. Typical applications and the benefits for customers using such systems are described.

  16. Cockpit canopy shattering using exploding wire techniques

    International Nuclear Information System (INIS)

    Novac, B M; Smith, I R; Downs, P R; Marston, P; Fahey, D

    2007-01-01

    This paper presents the principal experimental results provided by a preliminary investigation into the possibility of using exploding wire (EW) techniques to shatter the plastic cockpit canopy of a modern jet aircraft. The data provided forms the basis for a qualitative understanding of the physics of interaction between the plasma produced by an EW and the surrounding elasto-plastic material in which the wire is embedded. To optimize the shock-wave 'clean cutting' effect, the significance of the material, the dimensions of the exploding wire and the amplitude of the current and voltage pulses are all considered. This leads to important conclusions concerning both the characteristics of the EW and the optimum arrangement of the electrical circuit, with the single most important optimization factor being the peak electrical power input to the EW, rather than the dissipated Joule energy. A full-scale system relevant to an actual cockpit canopy shattering is outlined and relevant results are presented and discussed

  17. Reusable Hot-Wire Cable Cutter

    Science.gov (United States)

    Pauken, Michael T.; Steinkraus, Joel M.

    2010-01-01

    During the early development stage of balloon deployment systems for missions, nichrome wire cable cutters were often used in place of pyro-actuated cutters. Typically, a nichrome wire is wrapped around a bundle of polymer cables with a low melting point and connected to a relay-actuated electric circuit. The heat from the nichrome reduces the strength of the cable bundle, which quickly breaks under a mechanical load and can thus be used as a release mechanism for a deployment system. However, the use of hand-made heated nichrome wire for cutters is not very reliable. Often, the wrapped nichrome wire does not cut through the cable because it either pulls away from its power source or does not stay in contact with the cable being cut. Because nichrome is not readily soldered to copper wire, unreliable mechanical crimps are often made to connect the nichrome to an electric circuit. A self-contained device that is reusable and reliable was developed to sever cables for device release or deployment. The nichrome wire in this new device is housed within an enclosure to prevent it from being damaged by handling. The electric power leads are internally connected within the unit to the nichrome wire using a screw terminal connection. A bayonet plug, a quick and secure method of connecting the cutter to the power source, is used to connect the cutter to the power leads similar to those used in pyro-cutter devices. A small ceramic tube [0.25-in. wide 0.5-in. long (.6.4-mm wide 13-mm long)] houses a spiraled nichrome wire that is heated when a cable release action is required. The wire is formed into a spiral coil by wrapping it around a mandrel. It is then laid inside the ceramic tube so that it fits closely to the inner surface of the tube. The ceramic tube provides some thermal and electrical insulation so that most of the heat generated by the wire is directed toward the cable bundle in the center of the spiral. The ceramic tube is cemented into an aluminum block, which

  18. Magnetic characterization of the nickel layer protecting the copper wires in harsh applications

    Directory of Open Access Journals (Sweden)

    Roger Daniel

    2017-06-01

    Full Text Available High Temperature (HT° motor coils open new perspectives for extending the applications of electrical motors or generators to very harsh environments or for designing very high power density machines working with high internal temperature gradients. Over a temperature of 300°C, the classic enameled wire cannot work permanently, the turn-to-turn insulation must be inorganic and made with high temperature textiles or vitro-ceramic compounds. For both cases, a diffusion barrier must protect the copper wire against oxidation. The usual solution consists of adding a nickel layer that yields an excellent chemical protection. Unfortunately, the nickel has ferromagnetic properties that change a lot the skin effect in the HT wire at high frequencies. For many applications such as aeronautics, electrical machines are always associated with PWM inverters for their control. The windings must resist to high voltage short spikes caused by the fast fronted pulses imposed by the feeding inverter. The nickel protection layer of the HT° inorganic wire has a large influence on the high frequency behavior of coils and, consequently, on the magnitude of the voltage spikes. A good knowledge of the non-linear magnetic characteristics of this nickel layer is helpful for designing reliable HT inorganic coils. The paper presents a method able to characterize non-linear electromagnetic properties of this nickel layer up to 500°C.

  19. Simultaneous On-State Voltage and Bond-Wire Resistance Monitoring of Silicon Carbide MOSFETs

    Directory of Open Access Journals (Sweden)

    Nick Baker

    2017-03-01

    Full Text Available In fast switching power semiconductors, the use of a fourth terminal to provide the reference potential for the gate signal—known as a kelvin-source terminal—is becoming common. The introduction of this terminal presents opportunities for condition monitoring systems. This article demonstrates how the voltage between the kelvin-source and power-source can be used to specifically monitor bond-wire degradation. Meanwhile, the drain to kelvin-source voltage can be monitored to track defects in the semiconductor die or gate driver. Through an accelerated aging test on 20 A Silicon Carbide Metal-Oxide-Semiconductor-Field-Effect Transistors (MOSFETs, it is shown that there are opposing trends in the evolution of the on-state resistances of both the bond-wires and the MOSFET die. In summary, after 50,000 temperature cycles, the resistance of the bond-wires increased by up to 2 mΩ, while the on-state resistance of the MOSFET dies decreased by approximately 1 mΩ. The conventional failure precursor (monitoring a single forward voltage cannot distinguish between semiconductor die or bond-wire degradation. Therefore, the ability to monitor both these parameters due to the presence of an auxiliary-source terminal can provide more detailed information regarding the aging process of a device.

  20. Use of Kirschner wires with eyelets for tension band wiring of olecranon fractures.

    Science.gov (United States)

    Kim, Jin Young; Lee, Young Ho; Gong, Hyun Sik; Lee, Sang Lim; Lee, Sang Ki; Baek, Goo Hyun

    2013-09-01

    To evaluate the clinical and radiographic outcomes of tension band wiring of displaced olecranon fractures treated using Kirschner wires with eyelets to assess their clinical performance with respect to complications such as backing out of the K-wires, restriction of forearm rotation, and neurovascular injury. The authors retrospectively reviewed 44 patients treated for an isolated, displaced olecranon fracture and checked range of motion, postoperative pain, complications, and incidence of hardware removal. The mean follow-up period was 41 months (range, 26-73 mo). All fractures united, and anatomical reduction was achieved in all cases at final follow-up. Mean elbow flexion was 135° (range, 115° to 140°), and mean elbow extension was 4° (range, 0° to 15°). No pin migration, restriction of forearm rotation, or neurovascular injury occurred. Hardware removal was performed in 8 cases (18%). Compared to previous results with conventional Kirschner wires, no meaningful improvement in postoperative pain level or in the rate of hardware removal was observed. Tension band wiring using the pin studied produced excellent clinical and radiologic outcomes for the treatment of isolated, displaced Mayo type IIA and some type IIB olecranon fractures. The pin was effective in preventing the backing out of Kirschner wires and avoiding the complications associated with anterior cortical engagement of Kirschner wires, such as neurovascular injury or restriction of forearm rotation. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. Investigation of method for Stainless Steel Welding Wire as a Replacement for Arc Wire Comsumables

    Directory of Open Access Journals (Sweden)

    Koiprasert, H.

    2005-01-01

    Full Text Available Arc spraying as a coating method is being employed in various industrial applications as a part of maintenance service, and also as a surface engineering technique for many machine parts and components. The major cost in producing the arc spray coating is, however, based on the cost of the arc wire comsumables. This project was carried out to investigate the use of the commercially-available gas metal arc welding wire (GMAW wire as a cheaper alternative to the special-purpose arc wire comsumables. The wire material chosen for this early study is the 316L stainless steel, due to its popularity in many applications as a built-up coating for worn parts. The physical properties of the coatings produced from the two sets of 316L stainless steel wire were determined to be different in the percentage of porosity and the oxide content. The mechanical properties, including the tensile bond strength and the wear rate of the coatings produced from the two types of sprayed wire, were also different. This will, in turn, result in a slight difference in the performance of thecoatings.

  2. Modeling of Service-Drop Wires and Interior-Wiring Cables for Lightning Overvoltage Studies

    Science.gov (United States)

    Matsuura, Susumu; Noda, Taku; Nakamura, Masatoshi; Sakai, Hiroshi

    As the information society progresses, a variety of electronic appliances have come into wide use in common houses. If a lightning stroke causes faults or incorrect operations of these electronic appliances, a social economic loss is considered to be large. For this reason, the focus of lightning protection measures for distribution lines in Japan has expanded to include the low-voltage side of the distribution line in addition to the high-voltage side. In order to calculate lightning overvoltages at the low-voltage side, the surge characteristics of service-drop wires and interior-wiring cables have to be modeled accurately. First, this paper describes test results of the surge characteristics of service-drop wires and interior-wiring cables. The modal surge impedances and the propagation velocities of various service-drop wires and interior-wiring cables are obtained by the test. Based on the test results obtained, this paper proposes a modeling methodology of these wires and cables for accurate EMTP (Electro-Magnetic Transients Program) lightning overvoltage simulations. The proposed model is validated by comparing EMTP simulation results with field test results.

  3. Quantum conductance in silicon quantum wires

    CERN Document Server

    Bagraev, N T; Klyachkin, L E; Malyarenko, A M; Gehlhoff, W; Ivanov, V K; Shelykh, I A

    2002-01-01

    The results of investigations of electron and hole quantum conductance staircase in silicon quantum wires are presented. The characteristics of self-ordering quantum wells of n- and p-types, which from on the silicon (100) surface in the nonequilibrium boron diffusion process, are analyzed. The results of investigations of the quantum conductance as the function of temperature, carrier concentration and modulation degree of silicon quantum wires are given. It is found out, that the quantum conductance of the one-dimensional channels is observed, for the first time, at an elevated temperature (T >= 77 K)

  4. Numerical Simulation of Wire-Coating

    DEFF Research Database (Denmark)

    Wapperom, Peter; Hassager, Ole

    1999-01-01

    A finite element program has been used to analyze the wire-coating process of an MDPE melt. The melt is modeled by a nonisothermal Carreau model. The emphasis is on predicting an accurate temperature field. Therefore, it is necessary to include the heat conduction in the metal parts. A comparison...... is made with the results of a simulation that models the heat conduction in the metal head by means of a Biot boundary condition. The influence of the wire velocity, inlet temperature and power-law index will be examined....

  5. Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery.

    Science.gov (United States)

    Oh, You Na; Ha, Keong Jun; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won

    2015-08-01

    Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA) was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578), major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99), minor wound complications (3.6% vs. 2.0%, p=0.279), or mediastinitis (0.8% vs. 1.0%, p=1.00). Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068). The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

  6. Comparison of subtransverse process wiring and sublaminar wiring in the treatment of idiopathic thoracic scoliosis.

    Science.gov (United States)

    Akmeşe, Ramazan; Kemal Us, Ali

    2013-04-01

    A retrospective study. The objectives of this study were to show the advantages of an alternative segmental spinal instrumentation technique, termed subtransverse process wiring, and compare it with a sublaminar wiring technique in the treatment of idiopathic thoracic scoliosis. High rates of neurological complications and the need for high experience limit the use of the sublaminar wiring technique, although it is an effective segmental spinal instrumentation technique in the treatment of scoliosis. This is the first study to correlate sublaminar wiring and subtransverse process wiring techniques clinically. In a retrospective study, 64 patients with idiopathic thoracic scoliosis were chosen randomly. Nineteen patients were treated with subtransverse process wires (group A), and 45 patients were treated with sublaminar wires (group B). The mean follow-up period was 50.9 months (25 to 90 mo) in group A and 57.9 months (26 to 108 mo) in group B. The average deformity correction was 26.5 degrees (52.9%) in group A and 28.9 degrees (54.1%) in group B. The average correction loss was 2.9 degrees (17.2%) in group A and 6.4 degrees (27%) in group B. None of the patients developed neurological complications in group A. In group B, 5 (11.1%) intraoperative dural tears, 4 (8.9%) neurological deficits, and 8 (14.4%) transient dysesthesia syndromes were seen. The average operation time was 3.6 hours (3 to 4 h) in group A and 4.9 hours (3.75 to 8 h) in group B. The average replacement of blood (erythrocyte suspension) was 2.9 U (2 to 5 U) in group A and 3.1 U (2 to 6 U) in group B. Sublaminar wiring is a time-consuming technique with high risks of neurological complications, whereas subtransverse process wiring is an easy and neurologically safe method, which maintains effective deformity correction and stability of the correction.

  7. Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    You Na Oh

    2015-08-01

    Full Text Available Background: Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Methods: Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Results: Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578, major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99, minor wound complications (3.6% vs. 2.0%, p=0.279, or mediastinitis (0.8% vs. 1.0%, p=1.00. Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068. Conclusion: The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

  8. Magnetic anisotropy and anisotropic ballistic conductance of thin magnetic wires

    International Nuclear Information System (INIS)

    Sabirianov, R.

    2006-01-01

    The magnetocrystalline anisotropy of thin magnetic wires of iron and cobalt is quite different from the bulk phases. The spin moment of monatomic Fe wire may be as high as 3.4 μ B , while the orbital moment as high as 0.5 μ B . The magnetocrystalline anisotropy energy (MAE) was calculated for wires up to 0.6 nm in diameter starting from monatomic wire and adding consecutive shells for thicker wires. I observe that Fe wires exhibit the change sign with the stress applied along the wire. It means that easy axis may change from the direction along the wire to perpendicular to the wire. We find that ballistic conductance of the wire depends on the direction of the applied magnetic field, i.e. shows anisotropic ballistic magnetoresistance. This effect occurs due to the symmetry dependence of the splitting of degenerate bands in the applied field which changes the number of bands crossing the Fermi level. We find that the ballistic conductance changes with applied stress. Even for thicker wires the ballistic conductance changes by factor 2 on moderate tensile stain in our 5x4 model wire. Thus, the ballistic conductance of magnetic wires changes in the applied field due to the magnetostriction. This effect can be observed as large anisotropic BMR in the experiment

  9. Performance of an improved first generation optical CT scanner for 3D dosimetry

    International Nuclear Information System (INIS)

    Qian, Xin; Wuu, Cheng-Shie; Adamovics, John

    2013-01-01

    Performance analysis of a modified 3D dosimetry optical scanner based on the first generation optical CT scanner OCTOPUS is presented. The system consists of PRESAGE™ dosimeters, the modified 3D scanner, and a new developed in-house user control panel written in Labview program which provides more flexibility to optimize mechanical control and data acquisition technique. The total scanning time has been significantly reduced from initial 8 h to ∼2 h by using the modified scanner. The functional performance of the modified scanner has been evaluated in terms of the mechanical integrity uncertainty of the data acquisition process. Optical density distribution comparison between the modified scanner, OCTOPUS and the treatment plan system has been studied. It has been demonstrated that the agreement between the modified scanner and treatment plans is comparable with that between the OCTOPUS and treatment plans. (note)

  10. Experimental validation of a method characterizing bow tie filters in CT scanners using a real-time dose probe

    International Nuclear Information System (INIS)

    McKenney, Sarah E.; Nosratieh, Anita; Gelskey, Dale; Yang Kai; Huang Shinying; Chen Lin; Boone, John M.

    2011-01-01

    Purpose: Beam-shaping or ''bow tie'' (BT) filters are used to spatially modulate the x-ray beam in a CT scanner, but the conventional method of step-and-shoot measurement to characterize a beam's profile is tedious and time-consuming. The theory for characterization of bow tie relative attenuation (COBRA) method, which relies on a real-time dosimeter to address the issues of conventional measurement techniques, was previously demonstrated using computer simulations. In this study, the feasibility of the COBRA theory is further validated experimentally through the employment of a prototype real-time radiation meter and a known BT filter. Methods: The COBRA method consisted of four basic steps: (1) The probe was placed at the edge of a scanner's field of view; (2) a real-time signal train was collected as the scanner's gantry rotated with the x-ray beam on; (3) the signal train, without a BT filter, was modeled using peak values measured in the signal train of step 2; and (4) the relative attenuation of the BT filter was estimated from filtered and unfiltered data sets. The prototype probe was first verified to have an isotropic and linear response to incident x-rays. The COBRA method was then tested on a dedicated breast CT scanner with a custom-designed BT filter and compared to the conventional step-and-shoot characterization of the BT filter. Using basis decomposition of dual energy signal data, the thickness of the filter was estimated and compared to the BT filter's manufacturing specifications. The COBRA method was also demonstrated with a clinical whole body CT scanner using the body BT filter. The relative attenuation was calculated at four discrete x-ray tube potentials and used to estimate the thickness of the BT filter. Results: The prototype probe was found to have a linear and isotropic response to x-rays. The relative attenuation produced from the COBRA method fell within the error of the relative attenuation measured with the step-and-shoot method

  11. EDITORIAL More than a wire More than a wire

    Science.gov (United States)

    Demming, Anna

    2010-10-01

    Nanowires are the natural evolution of the connections in circuits when scaled down to nanometre sizes. On closer inspection, of course, the role of nanowires in developing new technologies is much more than just a current-bearing medium. By sizing the diameters of these objects down to the nanoscale, their properties become increasingly sensitive to factors such as the gas composition, temperature and incident light of their surrounding environment, as well as defects and variations in diameter. What becomes important in modern electronics innovations is not just what is connected, but how. Nanowires had already begun to attract the attention of researchers in the early 1990s as advances in imaging and measurement devices invited researchers to investigate the properties of these one-dimensional structures [1, 2]. This interest has sparked ingenious ways of fabricating nanowires such as the use of a DNA template. A collaboration of researchers at Louisiana Tech University in the US hs provided an overview of various methods to assemble conductive nanowires on a DNA template, including a summary of different approaches to stretching and positioning the templates [3]. Work in this area demonstrates a neat parallel for the role of DNA molecules as the building blocks of life and the foundations of nanoscale device architectures. Scientists at HP Labs in California are using nanowires to shrink the size of logic arrays [4]. One aspect of electronic interconnects that requires particular attention at nanoscale sizes is the effect of defects. The researchers at HP Labs demonstrate that their approach, which they name FPNI (field-programmable nanowire interconnect), is extremely tolerant of the high defect rates likely to be found in these nanoscale structures, and allows reduction in size and power without significantly sacrificing the clock rate. Another issue in scaling down electronics is the trend for an increasing resistivity with decreasing wire width. Researchers

  12. Transport of Energy by Ultra-Intense Laser-Generated Electrons in Nail-Wire Targets

    Science.gov (United States)

    Ma, T.; King, J. A.; Wei, M. S.; Beg, F. N.; Akli, K.; Stephens, R. B.; Hatchett, S. P.; Key, M. H.; MacKinnon, A. J.; Macphee, A. G.; Freeman, R. R.; van Woerkom, L.; Green, J. S.; Lancaster, K. L.; Norreys, P. A.; Theobald, W.; Mason, R.

    2008-04-01

    Understanding the transport of energy by relativistic fast electrons produced in petawatt (10^15 W) laser matter interactions is one of the key challenges in fast ignition of ICF. A simple and small target (nail-wire) was designed to investigate aspects of this transport. Nail-wire targets were irradiated using the Vulcan Petawatt Laser (0.8 ps, 3x10^20 W/cm-2) at the Rutherford Appleton Laboratory. A Cu Kα spherically bent crystal imager, a Highly Ordered Pyrolytic Graphite (HOPG) Spectrometer, and Single Photon Counting CCD were employed to give absolute Kα measurements. The penetration of hot electrons via the nail head into the bulk of the wire has been determined from the Kα data. XUV images (68 and 256 eV) indicate heating of a thin surface layer of the targets. A comparison of experimental results with the PIC/hybrid simulations using both LSP and e-PLAS will be presented at the meeting.

  13. EDF research on fast neutron reactors

    International Nuclear Information System (INIS)

    In order to make possible the calculation of the temperatures of the sodium, of the sheath and of the fuel in fast reactor assemblies, taking into account the mixing phenomena induced by the helicoidal wires, two design codes have been developed. Those codes have then been adapted for their integration in the Superalcyon system. This system shall constitute the reference tool for the development of those codes that shall manage Phenix, and other reactors of the family. Cooling accidents, thermohydraulic studies, and steam generator studies are also in progress

  14. Evolution of cementite morphology in pearlitic steel wire during wet wire drawing

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andrew; Hansen, Niels

    2010-01-01

    decreasing from 19 nm (ε = 0) to 2 nm (ε = 3.7) in correspondence with the reduction in wire diameter. The deformation of the cementite is strongly related to plastic deformation in the ferrite, with coarse slip steps, shear bands and cracks in the cementite plates/particles observed parallel to either {110...... microscope observations show that cementite plates become increasingly aligned with the wire axis as the drawing strain is increased. Measurements in the transmission electron microscope show that the cementite deforms plastically during wire drawing , with the average thickness of the cementite plates...

  15. Load-Deflection and Friction Properties of PEEK Wires as Alternative Orthodontic Wires

    OpenAIRE

    Tada, Yoshifumi; Hayakawa, Tohru; Nakamura, Yoshiki

    2017-01-01

    Polyetheretherketone (PEEK) is now attracting attention as an alternative to metal alloys in the dental field. In the present study, we evaluated the load-deflection characteristics of PEEK wires in addition to their frictional properties. Three types of PEEK wires are used: two sizes of rectangular shape, 0.016 ? 0.022 in2 and 0.019 ? 0.025 in2 (19-25PEEK), and rounded shape, diameter 0.016 in (16PEEK). As a control, Ni-Ti orthodontic wire, diameter 0.016 in, was used. The three-point bendin...

  16. Does the Use of Body Scanners Discriminate Overweight Flight Passengers? The Effect of Body Scanners on Body Image

    Directory of Open Access Journals (Sweden)

    Magdalena Laib

    2016-06-01

    Full Text Available Whereas the introduction of body scanners at airports has been accompanied by critical voices raising concerns that body scanners might have a negative impact on different minority groups, it has not been investigated thus far whether they might also have negative impacts on the average flight passenger and if the provision of adequate information might attenuate such negative impacts. Using a pre/post-design the current study examines the effect of a body scan in a controlled laboratory setting on the explicit and implicit body image of normal-weight and overweight people as assessed by questionnaires and an Implicit Association Test. Half of the sample received an information sheet concerning body scanners before they were scanned. While there was a negative impact of the body scan on the implicit body image of overweight participants, there was a positive impact on their explicit body image. The negative effect of the body scan was unaffected by receiving information. This study demonstrates that body scans do not only have negative effects on certain minority groups but potentially on a large proportion of the general public which suggests a critical reconsideration of the control procedures at airports, the training of the airport staff who is in charge of these procedures and the information flight passengers get about these procedures.

  17. Digitizing implant position locators on master casts: comparison of a noncontact scanner and a contact-probe scanner.

    Science.gov (United States)

    Holst, Stefan; Persson, Anna; Wichmann, Manfred; Karl, Matthias

    2012-01-01

    Although several investigations of the fit of computer-aided design/computer-assisted manufactured implant restorations have been reported in the literature, very limited information is available on the accuracy of dental scanners for surface data acquisition. The objective of this research project was to investigate the accuracy and repeatability of a three-dimensional noncontact laser scanning system based on conoscopic holography recording the spatial orientation of an implant in vitro. One master cast containing five nonparallel implant replicas with scan abutments (implant position locator [IPL], Nobel Biocare) was repeatedly digitized by two commercially available dental scanners and an industrial highprecision coordinate measuring machine as a reference. Repeated measurements of the center point and vector analysis were applied to determine the accuracy and repeatability of IPL orientation. The Wilcoxon signed rank test modified for equivalence was applied to determine whether the systems were equally accurate based on given threshold limits of 0.010, 0.005, and 0.001 mm. All between-system tests identified significant differences, although most differences were very small in absolute terms. Tests for equivalence based on difference windows were exploratorily significant for 0.010 and 0.005 mm. Conoscopic holography scan technology is a valid option to supplement dental touch-probe scanners for laboratory digitization of implant master casts.

  18. Methods for CT automatic exposure control protocol translation between scanner platforms.

    Science.gov (United States)

    McKenney, Sarah E; Seibert, J Anthony; Lamba, Ramit; Boone, John M

    2014-03-01

    An imaging facility with a diverse fleet of CT scanners faces considerable challenges when propagating CT protocols with consistent image quality and patient dose across scanner makes and models. Although some protocol parameters can comfortably remain constant among scanners (eg, tube voltage, gantry rotation time), the automatic exposure control (AEC) parameter, which selects the overall mA level during tube current modulation, is difficult to match among scanners, especially from different CT manufacturers. Objective methods for converting tube current modulation protocols among CT scanners were developed. Three CT scanners were investigated, a GE LightSpeed 16 scanner, a GE VCT scanner, and a Siemens Definition AS+ scanner. Translation of the AEC parameters such as noise index and quality reference mAs across CT scanners was specifically investigated. A variable-diameter poly(methyl methacrylate) phantom was imaged on the 3 scanners using a range of AEC parameters for each scanner. The phantom consisted of 5 cylindrical sections with diameters of 13, 16, 20, 25, and 32 cm. The protocol translation scheme was based on matching either the volumetric CT dose index or image noise (in Hounsfield units) between two different CT scanners. A series of analytic fit functions, corresponding to different patient sizes (phantom diameters), were developed from the measured CT data. These functions relate the AEC metric of the reference scanner, the GE LightSpeed 16 in this case, to the AEC metric of a secondary scanner. When translating protocols between different models of CT scanners (from the GE LightSpeed 16 reference scanner to the GE VCT system), the translation functions were linear. However, a power-law function was necessary to convert the AEC functions of the GE LightSpeed 16 reference scanner to the Siemens Definition AS+ secondary scanner, because of differences in the AEC functionality designed by these two companies. Protocol translation on the basis of

  19. STRUCTURE AND CHARACTERISTICS OF PATENTED HIGH-CARBON WIRE

    Directory of Open Access Journals (Sweden)

    A. Ju. Borisenko

    2011-01-01

    Full Text Available The influence of bainite structure on mechanical characteristics of wire of steel 80 after patenting is studied. The quantity and structure state of bainite, providing high complex of mechanical characteristics of high-carbon wire, is determined.

  20. Spectroscopic properties of colloidal indium phosphide quantum wires

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lin-Wang; Wang, Fudong; Yu, Heng; Li, Jingbo; Hang, Qingling; Zemlyanov, Dmitry; Gibbons, Patrick C.; Wang, Lin-Wang; Janes, David B.; Buhro, William E.

    2008-07-11

    Colloidal InP quantum wires are grown by the solution-liquid-solid (SLS) method, and passivated with the traditional quantum dots surfactants 1-hexadecylamine and tri-n-octylphosphine oxide. The size dependence of the band gaps in the wires are determined from the absorption spectra, and compared to other experimental results for InP quantum dots and wires, and to the predictions of theory. The photoluminescence behavior of the wires is also investigated. Efforts to enhance photoluminescence efficiencies through photochemical etching in the presence of HF result only in photochemical thinning or photo-oxidation, without a significant influence on quantum-wire photoluminescence. However, photo-oxidation produces residual dot and rod domains within the wires, which are luminescent. The results establish that the quantum-wire band gaps are weakly influenced by the nature of the surface passivation, and that colloidal quantum wires have intrinsically low photoluminescence efficiencies.

  1. The Effect of Wire Dimension, Type and Thickness of Coating Layer on Friction of Coated Stainless-Steel Arch Wires

    Directory of Open Access Journals (Sweden)

    Ahmed Abdulhussain Abbas

    2018-03-01

    Full Text Available Background/Purpose: Esthetic coated arch wires are the desired types to match esthetic brackets in the clinical orthodontics, but the presence of coating layer is greatly affect friction during sliding mechanics. The aims of this study were to evaluate the effect of total wire dimension with the type and thickness of coating layer on friction of coated stainless-steel wires. Methods: The sample of this study consisted of 140 segments of coated stainless-steel arch wires involving two wire dimensions (0.016 × 0.022 inch and 0.019 × 0.025 inch. The samples were supplied from seven companies (DB, RMO, TP, DANY, G&H, Highland and Hubit and the uncoated control samples were supplied from IOS company. Wire dimensions and thickness of coating layer were measured by the metallurgical light incident microscope and the static frictional force was measured using pulling the wire through set of ceramic brackets by the universal testing machine. The data were then statistically analyzed using ANOVA tests. Results: Generally measured wire dimensions do not match the stated dimensions by the manufacturer. The frictional forces of coated wires differ from uncoated control being higher in the labially coated wires and lesser in the fully Teflon coated wires owing to differences in the wire dimension, thickness of coating layer, and physical properties of coating materials. Conclusion: when tested in vitro, Teflon fully coated wires produce the least amount of friction.

  2. Fast Convolution Module (Fast Convolution Module)

    National Research Council Canada - National Science Library

    Bierens, L

    1997-01-01

    This report describes the design and realisation of a real-time range azimuth compression module, the so-called 'Fast Convolution Module', based on the fast convolution algorithm developed at TNO-FEL...

  3. Bandwidth improvement for germanium photodetector using wire bonding technology.

    Science.gov (United States)

    Chen, Guanyu; Yu, Yu; Deng, Shupeng; Liu, Lei; Zhang, Xinliang

    2015-10-05

    We demonstrate an ultrahigh speed germanium photodetector by introducing gold wires into the discrete ground electrodes with standard wire bonding technology. To engineer the parasitic parameter, the physical dimension of the gold wire used for wire bonding is specially designed with an inductance of about 450 pH. Simulation and experimental results show that the bandwidth of the photodetector can be effectively extended from less than 30 GHz to over 60 GHz.

  4. Signals analysis of fluxgate array for wire rope defaults

    International Nuclear Information System (INIS)

    Gu Wei; Chu Jianxin

    2005-01-01

    In order to detecting the magnetic leakage fields of the wire rope defaults, a transducer made up of the fluxgate array is designed, and a series of the characteristic values of wire rope defaults signals are defined. By processing the characteristic signals, the LF or LMA of wire rope are distinguished, and the default extent is estimated. The experiment results of the new method for detecting the wire rope faults are introduced

  5. MDT WIRE TENSION MEASUREMENT USING AN ELECTROSTATIC METHOD

    CERN Document Server

    Balla, A; Esposito, B; Felici, G; Nedosekin, A; Ponzio, B; Russo, V; Spitalieri, M C

    1998-01-01

    An automated system to measure wire tension in MDT tubes is presented.The method uses electrostatic forces between wire and tube to excite mechanical oscillation around the wire harmonic resonance. A LC oscillating circuit is used to measure capacitance variation due towire oscillation. Wire tension is determined by the frequency at which the wirereaches the maximum oscillation amplitude. Both the excitation and measuring circuits are controlled by a computer.

  6. Electricity: Residential Wiring. Secondary Schools. Curriculum Guide.

    Science.gov (United States)

    Trust Territory of the Pacific Islands Dept. of Education, Saipan.

    This curriculum guide on residential wiring for secondary students is one of six developed for inservice teachers at Marianas High School in Saipan. The guide provides the rationale, description, goals, and objectives of the program; the program of studies and performance objectives by levels; samples of lesson plans for effective delivery of…

  7. Building Trades. Carpentry, Electrical Wiring, Plumbing.

    Science.gov (United States)

    Missouri Univ., Columbia. Instructional Materials Lab.

    This curriculum guide contains 21 units of self-paced, self-contained instructional materials in the complete building trades curriculum. It is divided into vocational areas of carpentry, electrical wiring, and plumbing. The purpose of the curriculum is to provide minimum skills for disadvantaged and handicapped students entering mainstream…

  8. Description of CBETA magnet tuning wire holders

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, S. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-07-19

    A non-­magnetic insert will be placed directly inside the permanent magnet blocks in every CBETA Halbach magnet in order to hold a set of iron “tuning wires”. These wires have various lengths around the perimeter of the aperture in order to cancel multipole field errors from the permanent magnet blocks.

  9. Selective deposition by hot wire ALD

    NARCIS (Netherlands)

    Kovalgin, Alexey Y.; Yang, Mengdi; Aarnink, Antonius A.I.; Wolters, Robertus A.M.

    2018-01-01

    A method for selectively depositing a metal nlm onto a substrate is disclosed. In particular, the method comprising nowing a metal precursor onto the substrate and nowing a non-metal precursor onto the substrate,while contacting the non-metal precursor with a hot wire. Specincally, a reaction

  10. Studying superconducting Nb$_{3}$Sn wire

    CERN Multimedia

    AUTHOR|(CDS)2099575

    2015-01-01

    Studying superconducting Nb$_{3}$Sn wire. From the current experience from LHC and HL-LHC we know that the performance requirements for Nb$_{3}$Sn conductor for future circular collider are challenging and should exceed that of present state-of-the-art materials.

  11. Studying superconducting Nb3Sn wire

    CERN Multimedia

    AUTHOR|(CDS)2099575

    2015-01-01

    Studying superconducting Nb3Sn wire. From the current experience from LHC and HL-LHC we know that the performance requirements for Nb3Sn conductor for future circular collider are challenging and should exceed that of present state-of-the-art materials.

  12. Niobium Titanium and Copper wire samples

    CERN Multimedia

    2009-01-01

    Two wire samples, both for carrying 13'000Amperes. I sample is copper. The other is the Niobium Titanium wiring used in the LHC magnets. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. Magnet coils are made of copper-clad niobium–titanium cables — each wire in the cable consists of 9’000 niobium–titanium filaments ten times finer than a hair. The cables carry up to 12’500 amps and must withstand enormous electromagnetic forces. At full field, the force on one metre of magnet is comparable ...

  13. Two-wire Interface for Digital Microphones

    NARCIS (Netherlands)

    Groothedde, Wouter; Klumperink, Eric A.M.; Nauta, Bram; Eschauzier, Rudolphe Gustave Hubertus; van Rijn, Nico

    2003-01-01

    A two-wire interface for a digital microphone circuit includes a power line and a ground line. The interface utilizes the ground line as a "voltage active line" to transmit both clock and data signals between the digital microphone circuit and a receiving circuit. The digital microphone circuit

  14. Two-Wire interface for digital microphones

    NARCIS (Netherlands)

    Groothedde, Wouter; Klumperink, Eric A.M.; Nauta, Bram; Eschauzier, Rudolphe Gustave Hubertus; van Rijn, Nico

    2005-01-01

    A two-wire interface for a digital microphone circuit includes a power line and a ground line. The interface utilizes the ground line as a "voltage active line" to transmit both clock and data signals between the digital microphone circuit and a receiving circuit. The digital microphone circuit

  15. Organics and Biological Scanner (OrBis): Standoff, fast, large area line scanner for non-destructive, sensitive, detection of biological and organic materials

    Data.gov (United States)

    National Aeronautics and Space Administration — Use a small 532 nm pulsed laser with a 0.1 mJ/pulse energy operating at 1 kHz Use a ultra-compact spectrometer with 1-inch collection optics and working distance of...

  16. Simultaneous Investigation of Hot-electron Transport and Preplasma Formation in Cone-wire Targets

    Science.gov (United States)

    Friesen, H.; Tiedje, H. F.; Singh, S.; Tsui, Y. Y.; Fedosejevs, R.; Ma, T.; Hey, D.; Ping, Y.; Chen, C. D.; Macphee, A.; Key, M. H.; McLean, H. S.; Patel, P.; MacKinnon, A.; Pasley, J.; Akli, K. U.; Stephens, R.; Link, A.; Schumacher, D. W.; Freeman, R. R.; van Woerkom, L. D.; Westover, B.; Wei, M. S.; Beg, F. N.

    2010-11-01

    The generation and transport of MeV electrons is essential to the realization of Fast Ignition fusion. An important factor in determining the hot electron source is the preplasma distribution that is inevitably formed even in high-contrast short-pulse laser systems. A larger preplasma moves the critical surface further from the region where heating is required, and has a significant effect on the electron source and transport. In this paper we present analysis of results where bremstrahhlung emission from the preplasma region was imaged simultaneously with k-alpha emission from a copper tracer in cone-wire targets using a grazing-incidence x-Kirkpatrick-Baez x-ray microscope. The predicted scalings from simulations and theory will be compared with experimental results to determine unique characteristics of how the hot electron source and transport are affected by the presence of the wire as well as preplasma.

  17. Seebeck Changes Due to Residual Cold-Work and Reversible Effects in Type K Bare-Wire Thermocouples

    Science.gov (United States)

    Webster, E. S.

    2017-09-01

    Type K thermocouples are the most commonly used thermocouple for industrial measurements because of their low cost, wide temperature range, and durability. As with all base-metal thermocouples, Type K is made to match a mathematical temperature-to-emf relationship and not a prescribed alloy formulation. Because different manufacturers use varying alloy formulations and manufacturing techniques, different Type K thermocouples exhibit a range of drift and hysteresis characteristics, largely due to ordering effects in the positive (K+) thermoelement. In this study, these effects are assessed in detail for temperatures below 700°C in the Type K wires from nine manufacturers. A linear gradient furnace and a high-resolution homogeneity scanner combined with the judicious use of annealing processes allow measurements that separately identify the effects of cold-work, ordering, and oxidation to be made. The results show most K+ alloys develop significant errors, but the magnitudes of the contributions of each process vary substantially between the different K+ wires. In practical applications, the measurement uncertainties achievable with Type K therefore depend not only on the wire formulation but also on the temperature, period of exposure, and, most importantly, the thermal treatments prior to use.

  18. Myocardium scintigraphy and coronaries scanner: results and respective contribution of these two examinations; Scintigraphie myocardique et scanner coronaire: resultats et apport respectif des deux examens

    Energy Technology Data Exchange (ETDEWEB)

    Songy, B.; Balestrini, V.; Sablayrolles, J.L.; Vigoni, F.; Lussato, D. [Centre cardiologique du Nord (CCN), Saint-Denis, (France); Faccio, F. [fondation San Geronimo, Santa Fe, (Argentina)

    2009-05-15

    The objective were to evaluate the results and the respective contribution of the myocardium scintigraphy and the coro-scanner. It exists an excellent correlation between a normal scanner and a normal scintigraphy (97%). 30% of patients having non tight stenosis at scanner and 60% of these ones having tight stenosis have a scintigraphy ischemia; An abnormal scanner, whatever be the the degree of stenosis must be completed by a test of myocardium ischemia. The actual limitations of the coro-scanner (64 gills) are in relation with its spatial resolution (quantification) and temporal resolution (right coronary). The choice of the diagnosis examination to realize in first intention must depend on the age and prevalence of the coronary disease. (N.C.)

  19. Structured Wiring Systems: Bringing Sanity to Network Cabling!

    Science.gov (United States)

    Learn, Larry L., Ed.

    1995-01-01

    While most organizations, including libraries, can benefit from a structured wiring system, few likely have the expertise and resources to place, specify, and install network cabling by themselves. This article reviews common wiring plans, addresses basic concepts of structured wiring systems, and discusses the importance and benefits of such a…

  20. Modeling, simulation and parametric optimization of wire EDM ...

    African Journals Online (AJOL)

    In the present work, quadratic mathematical models have been derived to represent the process behavior of wire electrical discharge machining (WEDM) operation. Experiments have been conducted with six process parameters: discharge current, pulse duration, pulse frequency, wire speed, wire tension and dielectric flow ...

  1. Bonding of a niobium wire to a niobium thin film

    NARCIS (Netherlands)

    Jaszczuk, W.; Jaszczuk, W.; ter Brake, Hermanus J.M.; Flokstra, Jakob; Veldhuis, Dick; Stammis, R.; Rogalla, Horst

    1991-01-01

    A method for bonding a niobium wire to a niobium thin film is described. The bonds are to be used as superconducting connections between wire-wound gradiometers and thin-film coupling coils on DC SQUIDS. The method is characterized by two steps. Firstly, the hardness of the niobium wire is reduced

  2. 77 FR 28404 - Galvanized Steel Wire From China and Mexico

    Science.gov (United States)

    2012-05-14

    ...)] Galvanized Steel Wire From China and Mexico Determinations On the basis of the record \\1\\ developed in the... reason of imports from Mexico of galvanized steel wire, provided for in subheadings 7217.20.30, 7217.20... galvanized steel wire from China and Mexico were sold at LTFV within the meaning of 733(b) of the Act (19 U.S...

  3. 76 FR 29266 - Galvanized Steel Wire From China and Mexico

    Science.gov (United States)

    2011-05-20

    ...)] Galvanized Steel Wire From China and Mexico Determinations On the basis of the record \\1\\ developed in the... reason of imports from China and Mexico of galvanized steel wire, provided for in subheading 7217.20.30... subsidized imports of galvanized steel wire from China and Mexico. Accordingly, effective March 31, 2011, the...

  4. 46 CFR 111.30-19 - Buses and wiring.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Buses and wiring. 111.30-19 Section 111.30-19 Shipping... REQUIREMENTS Switchboards § 111.30-19 Buses and wiring. (a) General. Each bus must meet the requirements of... 60092-302 (clause 7) (incorporated by reference; see 46 CFR 110.10-1). (b) Wiring. Instrumentation and...

  5. Basic Wiring. Third Edition. Teacher Edition [and] Student Edition.

    Science.gov (United States)

    Kaltwasser, Stan; Flowers, Gary; Blasingame, Don; Batson, Larry; Ipock, Dan; Carroll, Charles; Friesen, Wade; Fleming, Glenn

    This publication contains both a teacher edition and a student edition of materials for a foundation course in an electrical wiring program. The course introduces basic concepts and skills that are prerequisites to residential wiring and commercial and industrial wiring courses. The contents of the materials are tied to measurable and observable…

  6. 29 CFR 1926.404 - Wiring design and protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Wiring design and protection. 1926.404 Section 1926.404... Requirements § 1926.404 Wiring design and protection. (a) Use and identification of grounded and grounding... construction sites, which are not a part of the permanent wiring of the building or structure and which are in...

  7. 46 CFR 129.340 - Cable and wiring.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Cable and wiring. 129.340 Section 129.340 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.340 Cable and wiring. (a) If individual wires, rather than...

  8. 46 CFR 28.370 - Wiring methods and materials.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Wiring methods and materials. 28.370 Section 28.370... Operate With More Than 16 Individuals on Board § 28.370 Wiring methods and materials. (a) All cable and... not more than 10 percent. (c) Cable and wiring not serving equipment in a high risk fire area such as...

  9. 46 CFR 28.865 - Wiring methods and materials.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Wiring methods and materials. 28.865 Section 28.865... FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.865 Wiring methods and materials. (a) All cable... terminals is not more than 10 percent. (c) Cable and wiring not serving equipment in high risk fire areas...

  10. 77 FR 1504 - Stainless Steel Wire Rod From India

    Science.gov (United States)

    2012-01-10

    ... COMMISSION Stainless Steel Wire Rod From India Determination On the basis of the record \\1\\ developed in the... antidumping duty order on stainless steel wire rod From India would be likely to lead to continuation or... contained in USITC Publication 4300 (January 2012), entitled Stainless Steel Wire Rod From India...

  11. Experimental investigation of industrial copper deformed by wire ...

    African Journals Online (AJOL)

    drawing on microstructure and physical properties of industrial copper wires. Copper wires were provided by E.N.I.CA.Biskra (Algeria). We investigated some wires with different strain levels (as received, 1.20, 2.10, and ε = 3.35).

  12. A laser-wire system for the International Linear Collider

    Indian Academy of Sciences (India)

    Laser-wire; accelerator test facility; laser; optical system; Compton; beam emittance; MOPA; fiber laser. Abstract. A new laser-wire has been installed in the extraction line of the ATF at KEK. It aims at demonstrating that laser-wires can be used to measure micrometre scale beam size. In parallel, studies have been made to ...

  13. A laser-wire system for the International Linear Collider

    Indian Academy of Sciences (India)

    ... line of the ATF at KEK. It aims at demonstrating that laser-wires can be used to measure micrometre scale beam size. In parallel, studies have been made to specify a laser suitable for the ILC laser-wires. Keywords. Laser-wire; accelerator test facility; laser; optical system; Compton; beam emittance; MOPA; fiber laser.

  14. Lunar Module Wiring Design Considerations and Failure Modes

    Science.gov (United States)

    Interbartolo, Michael

    2009-01-01

    This slide presentation reviews the considerations for the design of wiring for the Lunar Module. Included are a review of the choice of conductors and insulations, the wire splicing (i.e., crimping, and soldering), the wire connectors, and the fabrication of the wire harnesses. The problems in fabrication include the wires being the wrong length, the damage due to the sharp edges, the requried use of temproary protective covers and inadequate training. The problems in the wire harness installation include damge from sharp eges, work on adjacent harnesses, connector damage, and breaking wires. Engineering suggestions from the Apollo-era in reference to the conductors that are reviewed include: the use of plated conductors, and the use of alloys for stronger wiring. In refernce to insulation, the suggestions from Apollo era include the use of polymer tape-wrap wire insulation due to the light weight, however, other types of modern insulation might be more cost-effective. In reference to wire splices and terminal boards the suggestions from the Apollo Era include the use of crimp splices as superior to solder splices, joining multiple wire to a common point using modular plug-ins might be more reliable, but are heavier than crimp splicing. For connectors, the lessons from the Apollo era indicate that a rear environmental seal that does not require additional potting is preferred, and pins should be crimped or welded to the incoming wires and be removable from the rear of the connector.

  15. Load-deflection characteristics of superelastic nickel-titanium wires.

    NARCIS (Netherlands)

    Bartzela, T.; Senn, C.; Wichelhaus, A.

    2007-01-01

    OBJECTIVE: To determine the mechanical properties of commercially available thermodynamic wires and to classify these wires mathematically into different groups. MATERIALS AND METHODS: The samples examined were 48 nickel-titanium (NiTi) alloy orthodontic wires commercially available from five

  16. 30 CFR 77.705 - Guy wires; grounding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Guy wires; grounding. 77.705 Section 77.705... MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Grounding § 77.705 Guy wires; grounding. Guy wires from poles supporting high-voltage transmission lines shall be...

  17. Electronic conductance of quantum wire with serial periodic potential structures

    International Nuclear Information System (INIS)

    Fayad, Hisham M.; Shabat, Mohammed M.; Abdus Salam International Centre for Theoretical Physics, Trieste

    2000-08-01

    A theory based on the total transfer matrix is presented to investigate the electronic conductance in a quantum wire with serial periodic potentials. We apply the formalism in computation of the electronic conductance in a wire with different physical parameters of the wire structure. The numerical results could be used in designing some future quantum electronic devices. (author)

  18. Communication and wiring in the cortical connectome.

    Science.gov (United States)

    Budd, Julian M L; Kisvárday, Zoltán F

    2012-01-01

    In cerebral cortex, the huge mass of axonal wiring that carries information between near and distant neurons is thought to provide the neural substrate for cognitive and perceptual function. The goal of mapping the connectivity of cortical axons at different spatial scales, the cortical connectome, is to trace the paths of information flow in cerebral cortex. To appreciate the relationship between the connectome and cortical function, we need to discover the nature and purpose of the wiring principles underlying cortical connectivity. A popular explanation has been that axonal length is strictly minimized both within and between cortical regions. In contrast, we have hypothesized the existence of a multi-scale principle of cortical wiring where to optimize communication there is a trade-off between spatial (construction) and temporal (routing) costs. Here, using recent evidence concerning cortical spatial networks we critically evaluate this hypothesis at neuron, local circuit, and pathway scales. We report three main conclusions. First, the axonal and dendritic arbor morphology of single neocortical neurons may be governed by a similar wiring principle, one that balances the conservation of cellular material and conduction delay. Second, the same principle may be observed for fiber tracts connecting cortical regions. Third, the absence of sufficient local circuit data currently prohibits any meaningful assessment of the hypothesis at this scale of cortical organization. To avoid neglecting neuron and microcircuit levels of cortical organization, the connectome framework should incorporate more morphological description. In addition, structural analyses of temporal cost for cortical circuits should take account of both axonal conduction and neuronal integration delays, which appear mostly of the same order of magnitude. We conclude the hypothesized trade-off between spatial and temporal costs may potentially offer a powerful explanation for cortical wiring patterns.

  19. Reducing radiation exposure with iterative reconstruction: an inter- and intra-scanner analysis.

    Science.gov (United States)

    Rohr, Aaron; Wick, Jo; Hill, Jacqueline; Walter, Carissa; Irani, Neville; Best, Shaun; Miller, Kirk; Ash, Ryan

    2017-01-01

    Our purpose in this study was to compare delivered radiation exposure via computed tomography dose index volume (CTDI vol ) and dose length production (DLP) measurements from computed tomography (CT) examinations performed on scanners with and without image-quality enhancing iterative reconstruction (IR) software. A retrospective analysis was conducted on randomly selected chest, abdomen, and/or pelvis CT examinations from three different scanners from 1 January 2013 to 31 December 2013. CTDI vol and DLP measurements were obtained from two CT scanners with and one CT scanner without IR software. To evaluate inter-scanner variability, we compared measurements from the same model CT scanners, one with and one without IR software. To evaluate intra-scanner variability, we compared measurements between two scanners with IR software from different manufacturers. CT scanners with IR software aided in the overall reduction in radiation exposure, measured as CTDI vol by 30% and DLP by 39% when compared to a scanner without IR. There was no significant difference in CTDl vol or DLP measurements across different manufacturers with IR software. As a result, IR software significantly decreased the radiation exposure to patients, but there were no differences in radiation measurements across CT manufacturers with IR software.

  20. Evaluation of scanners for C-scan imaging in nondestructive inspection of aircraft

    Energy Technology Data Exchange (ETDEWEB)

    Gieske, J.H.

    1994-04-01

    The goal of this project was to produce a document that contains information on the usability and performance of commercially available, fieldable, and portable scanner systems as they apply to aircraft NDI inspections. In particular, the scanners are used to generate images of eddy current, ultrasonic, or bond tester inspection data. The scanner designs include manual scanners, semiautomated scanners, and fully automated scanners. A brief description of the functionality of each scanner type, a sketch, and a fist of the companies that support the particular design are provided. Vendors of each scanner type provided hands-on demonstrations of their equipment on real aircraft samples in the FAA Aging Aircraft Nondestructive Inspection Validation Center (AANC) in Albuquerque, NM. From evaluations recorded during the demonstrations, a matrix of scanner features and factors and ranking of the capabilities and limitations of the design, portability, articulation, performance, usability, and computer hardware/software was constructed to provide a quick reference for comparing the different scanner types. Illustrations of C-scan images obtained during the demonstration are shown.

  1. Temperature dependence of APD-based PET scanners

    International Nuclear Information System (INIS)

    Keereman, Vincent; Van Holen, Roel; Vandenberghe, Stefaan; Vanhove, Christian

    2013-01-01

    Purpose: Solid state detectors such as avalanche photodiodes (APDs) are increasingly being used in PET detectors. One of the disadvantages of APDs is the strong decrease of their gain factor with increasing ambient temperature. The light yield of most scintillation crystals also decreases when ambient temperature is increased. Both effects lead to considerable temperature dependence of the performance of APD-based PET scanners. In this paper, the authors propose a model for this dependence and the performance of the LabPET8 APD-based small animal PET scanner is evaluated at different temperatures.Methods: The model proposes that the effect of increasing temperature on the energy histogram of an APD-based PET scanner is a compression of the histogram along the energy axis. The energy histogram of the LabPET system was acquired at 21 °C and 25 °C to verify the validity of this model. Using the proposed model, the effect of temperature on system sensitivity was simulated for different detector temperature coefficients and temperatures. Subsequently, the effect of short term and long term temperature changes on the peak sensitivity of the LabPET system was measured. The axial sensitivity profile was measured at 21 °C and 24 °C following the NEMA NU 4-2008 standard. System spatial resolution was also evaluated. Furthermore, scatter fraction, count losses and random coincidences were evaluated at different temperatures. Image quality was also investigated.Results: As predicted by the model, the photopeak energy at 25 °C is lower than at 21 °C with a shift of approximately 6% per °C. Simulations showed that this results in an approximately linear decrease of sensitivity when temperature is increased from 21 °C to 24 °C and energy thresholds are constant. Experimental evaluation of the peak sensitivity at different temperatures showed a strong linear correlation for short term (2.32 kcps/MBq/°C = 12%/°C, R = −0.95) and long term (1.92 kcps/MBq/°C = 10%/

  2. Research regarding wires elastic deformations influence on joints positioning of a wire-driven robotic arm

    Science.gov (United States)

    Ciofu, C.; Stan, G.

    2016-08-01

    In this paper, we present the influence of driving wires deformation on positioning precision of joints from an elephant's trunk robotic arm. Robotic arms driven by wires have the joint accuracy largely depending on wires rigidity. The joint moment of resistance causes elastic deformation of wires and it is determined by: manipulated object load, weight loads previous to the analyzed joint and inherent resistance moment of joint. Static load analysis emphasizes the particular wires elastic deformation of each driven joint from an elephant's trunk robotic arm with five degrees of freedom. We consider the case of a constant manipulated load. Errors from each driving system of joints are not part of the closed loop system. Thus, precision positioning depends on wires elastic deformation which is about microns and causes angle deviation of joints about tens of minutes of sexagesimal degrees. The closer the joints to base arm the smaller positioning precision of joint. The obtained results are necessary for further compensation made by electronic corrections in the programming algorithm of the elephant's trunk robotic arm to improve accuracy.

  3. U.S. Navy Wire-Rope Handbook. Volume 1. Design and Engineering of Wire-Rope Systems

    Science.gov (United States)

    1976-01-01

    percent nickel and are designated "Type 304 " and "Type 302" by the American Iron and Steel Institute ( AISI ). Type 304 stainless steel rope may be...from AISI Specifica- tion XYZ14 on Alloy Steel Wire) .... ............ ... 3-2 3-2. Typical Load-Elongation Behavior of Wire Rope .... ...... 3-9 3...Cosecants .......... ................... ... 10-S 10-11. Physical and Mechanical Properties of Wire ............ . .. 10-10 10-12. Wire Gauges

  4. Generation and Transport of Hot Electrons in Cone-Wire Targets

    Science.gov (United States)

    Beg, Farhat

    2009-11-01

    We present results from a series of experiments where cone-wire targets in various configurations were employed both to assess hot electron coupling efficiency, and to reveal the source temperature of the hot electrons. Initial experiments were performed on the Vulcan petawatt laser at the Rutherford Appleton Laboratory and Titan laser at the Lawrence Livermore National Laboratory. Results with aluminum cones joined to Cu wires of diameters from 10 to 40 μm show that the laser coupling efficiency to electron energy within the wire is proportional to the cross sectional area of the wire. In addition, coupling into the wire was observed to decrease with the laser prepulse and cone-wall thickness. More recently, this study was extended, using the OMEGA EP laser. The resulting changes in coupling energy give indications of the scaling as we approach FI-relevant conditions. Requirements for FI scale fast ignition cone parameters: tip thickness, wall thickness, laser prepulse and laser pulse length, will be discussed. In collaboration with T. Yabuuchi, T. Ma, D. Higginson, H. Sawada, J. King, M.H. Key, K.U. Akli, Al Elsholz, D. Batani, H. Chen, R.R. Freeman, L. Gizzi, J. Green, S. Hatchett, D. Hey, P. Jaanimagi, J. Koch, K. L. Lancaster, D.Larson, A.J. MacKinnon, H. McLean, A. MacPhee, P.A. Norreys, P.K Patel, R. B. Stephens, W. Theobald, R. Town, M. Wei, S. Wilks, Roger Van Maren, B. Westover and L. VanWoerkom.

  5. VEGETATION CHARACTERISTICS USING MULTI-RETURN TERRESTRIAL LASER SCANNER

    Directory of Open Access Journals (Sweden)

    F. Pirotti

    2012-09-01

    Full Text Available Distinguishing vegetation characteristics in a terrestrial laser scanner dataset is an interesting issue for environmental assessment. Methods for filtering vegetation points to distinguish them from ground class have been widely studied mostly on datasets derived from airborne laser scanner, less so for terrestrial laser scanners (TLS. Recent developments in terrestrial laser sensors – further ranges, faster acquisition and multiple return echoes for some models – has risen interest for surface modelling applications. The downside of TLS is that a typical dataset has a very dense cloud, with obvious side-effects on post-processing time. Here we use a scan from a sensor which provides evaluation of multiple target echoes providing with more than 70 million points on our study area. The area presents a complex set of features ranging from dense vegetation undergrowth to very steep and uneven terrain. The method consists on a first step which subsets the original points to define ground candidates by taking into account the ordinal return number and the amplitude. Next a custom progressive morphological filter (closing operation is applied on ground candidate points using multidimensional (varying resolutions grids and a structure element to determine cell values. Vegetation density mapping over the area is then estimated using a weighted ration of point counts in the tri-dimensional space over each cell. The overall result is a pipeline for processing TLS points clouds with minimal user interaction, producing a Digital Terrain Model (DTM, a Digital Surface Model (DSM a vegetation density map and a derived canopy height model (CHM. Results on DTM show an accuracy (RMSE of 0.307 m with a mean error of 0.0573 m compared to a control DTM extracted from Terrascan's progressive triangulation procedure. The derived CHM was tested over 30 tree heights resulting in 27 trees having an absolute error value below 0.2 m (three were just below 0.7 m.

  6. Quality control of some CT scanners in Khartoum state

    International Nuclear Information System (INIS)

    Yousif, Ali Mohammed Ali

    2013-06-01

    This study conduced with the aim to evaluate the performance of three CT scanner in Khartoum-Sudan through extensive quality control measurements. Image quality was assessed using a CATPHAN 412 CT image quality phantom. Image quality parameters evaluated were: CT image noise, uniformity, CT number linearity, Low Contrast Resolution, High Contrast Resolution, measurements were performed in accordance with guidelines set out by the Institute of physical science and engineering in medicine (IPEM 91). Image quality parameters tested were within the apoplectic limit specified in the relevant CT guidelines. Measured slice thickness ranged between 9.66-10.5 mm for large slice and 5.25-5.88 for medium slice. The correlation coefficient (R) between the measured and the reference CT number was better than 0.99 for all CT scanners. High resolution for large slice was 7 L P/ cm and 8 L P/ cm for small slice. Low contrast resolution with 1.0% nominal level ranged between 2-3 mm diameter of disc for large slice and 4-7 mm diameter disc for small slice. The measured noise ranged between 1.4-3.4 HU for large slice and 2.92-4.08 HU for small slice. Uniformity ranged between 3.08 to 2.075 HU for large slice and 3.22 to 1.4 HU for small slice thickness. The results indicate that routine maintenance, service and calibration, as well as the frequent quality control of CT scanners play a key rote in achieving the best performance of the system. Since computed tomography (CT) contributes the most to the collective dose compared to other radiological examinations, it is a necessity for quality control and quality assurance programs to be established in each radiology department.(Author)

  7. Optical monitoring of scoliosis by 3D medical laser scanner

    Science.gov (United States)

    Rodríguez-Quiñonez, Julio C.; Sergiyenko, Oleg Yu.; Preciado, Luis C. Basaca; Tyrsa, Vera V.; Gurko, Alexander G.; Podrygalo, Mikhail A.; Lopez, Moises Rivas; Balbuena, Daniel Hernandez

    2014-03-01

    Three dimensional recording of the human body surface or anatomical areas have gained importance in many medical applications. In this paper, our 3D Medical Laser Scanner is presented. It is based on the novel principle of dynamic triangulation. We analyze the method of operation, medical applications, orthopedically diseases as Scoliosis and the most common types of skin to employ the system the most proper way. It is analyzed a group of medical problems related to the application of optical scanning in optimal way. Finally, experiments are conducted to verify the performance of the proposed system and its method uncertainty.

  8. Computed tomography scanner applied to soil compaction studies

    International Nuclear Information System (INIS)

    Vaz, C.M.P.

    1989-11-01

    The soil compaction problem was studied using a first generation computed tomography scanner (CT). This apparatus gets images of soil cross sections samples, with resolution of a few millimeters. We performed the following laboratory and field experiments: basic experiments of equipment calibrations and resolutions studies; measurements of compacted soil thin layers; measurements of soil compaction caused by agricultural tools; stress-strain modelling in confined soil sample, with several moisture degree; characterizations of soil bulk density profile with samples collected in a hole (trench), comparing with a cone penetrometer technique. (author)

  9. A new electronic read-out for the YAPPET scanner

    CERN Document Server

    Damiani, C; Malaguti, R; Guerra, A D; Domenico, G D; Zavattini, G

    2002-01-01

    A small animal PET-SPECT scanner (YAPPET) prototype was built at the Physics Department of the Ferrara University and is presently being used at the Nuclear Medicine Department for radiopharmaceutical studies on rats. The first YAPPET prototype shows very good performances, but needs some improvements before it can be fully used for intensive radiopharmaceutical research. The main problem of the actual prototype is its heavy electronics, based on NIM and CAMAC standard modules. For this reason a new, compact read-out electronics was developed and tested. The results of a first series of tests made on the first prototype will be presented in the paper.

  10. Compact implementation of dynamic receive apodization in ultrasound scanners

    DEFF Research Database (Denmark)

    Tomov, Borislav Gueorguiev; Jensen, Jørgen Arendt

    2004-01-01

    The image quality in medical ultrasound scanners is determined by several factors, one of which is the ability of the receive beamformer to change the aperture weighting function with depth and beam angle. In digital beamformers, precise dynamic apodization can be achieved by representing the fun...... operate at 129.82 MHz and occupies 1.28 million gates. Simulated in Matlab, a 64-channel beamformer provides gray scale image with around 55 dB dynamic range. The beamformed data can also be used for flow estimation....

  11. Oil slick studies using photographic and multispectral scanner data.

    Science.gov (United States)

    Munday, J. C., Jr.; Macintyre, W. G.; Penney, M. E.; Oberholtzer, J. D.

    1971-01-01

    Field studies of spills of Nos. 6 (Bunker C), 4, and 2 fuel oils and menhaden fish oil in the southern Chesapeake Bay have been supplemented with aerial photographic and multispectral scanner data. Thin films showed best in ultraviolet and blue bands and thick films in the green. Color film was effective for all thicknesses. Thermal infrared imagery provided clear detection, but required field temperature and thickness data to distinguish thickness/emissivity variations from temperature variations. Slick spreading rates agree with the theory of Fay (1969); further study of spreading is in progress.

  12. Demonstration: A smartphone 3D functional brain scanner

    DEFF Research Database (Denmark)

    Stahlhut, Carsten; Stopczynski, Arkadiusz; Larsen, Jakob Eg

    We demonstrate a fully portable 3D real-time functional brain scanner consisting of a wireless 14-channel ‘Neuroheadset‘ (Emotiv EPOC) and a Nokia N900 smartphone. The novelty of our system is the ability to perform real-time functional brain imaging on a smartphone device, including stimulus...... tools are preferred. Source localization is implemented locally on the phone with a 3D brain model consisting of 1,028 vertices and 2,048 triangles stored in the mobile application. Our system design benefits from the possibility of being able to integrate with multiple hardware platforms (smartphones...

  13. Construction of a ct scanner using heavy ions or protons

    International Nuclear Information System (INIS)

    Elliott, D.O.

    1981-01-01

    A computed tomography x-ray scanner, in which a monochromatic xray beam is generated by irradiating an x-ray producing target with high energy monoenergetic ions. The ion beam is preferably produced by a cyclotron. The x-ray beam is preferably rotated through an object to be scanned by angularly displacing the ion beam and target about the center axis of the object. A conventional x-ray detector array, a signal and data processor and imaging means are provided to convert detected x-ray absorption measurements into a two-dimensional visual image of the scanned object cross-section

  14. Mapping of MAC Address with Moving WiFi Scanner

    Directory of Open Access Journals (Sweden)

    Arief Hidayat

    2017-10-01

    Full Text Available Recently, Wifi is one of the most useful technologies that can be used for detecting and counting MAC Address. This paper described using of WiFi scanner which carried out seven times circulated the bus. The method used WiFi and GPS are to counting MAC address as raw data from the pedestrian smartphone, bus passenger or WiFi devices near from the bus as long as the bus going around the route. There are seven processes to make map WiFi data.

  15. Quality assurance for CT scanners and NMR imagers

    International Nuclear Information System (INIS)

    Williams, J.L.; Howarth, W.

    1986-01-01

    Quality Assurance is an essential part of management and the application of its disciplines to the purchase and use of CT and MR scanners is particularly important. The Purchaser and User have the leading role. They must take into account the need for a precise specification which will form part of the contract placed on the Supplier, the basis of acceptance and of maintenance of the equipment. The training of staff is also important. The Scientific and Technical Branch of the DHSS has a programme of work intended to help the Purchaser and User in this role. (author)

  16. A PC-controlled microwave tomographic scanner for breast imaging

    Science.gov (United States)

    Padhi, Shantanu; Howard, John; Fhager, A.; Bengtsson, Sebastian

    2011-01-01

    This article presents the design and development of a personal computer based controller for a microwave tomographic system for breast cancer detection. The system uses motorized, dual-polarized antennas and a custom-made GUI interface to control stepper motors, a wideband vector network analyzer (VNA) and to coordinate data acquisition and archival in a local MDSPlus database. Both copolar and cross-polar scattered field components can be measured directly. Experimental results are presented to validate the various functionalities of the scanner.

  17. Near-field optical spectroscopy of single quantum wires

    Science.gov (United States)

    Harris, T. D.; Gershoni, D.; Grober, R. D.; Pfeiffer, L.; West, K.; Chand, N.

    1996-02-01

    Low temperature near-field scanning optical microscopy is used for spectroscopic studies of single, nanometer dimension, cleaved edge overgrown quantum wires. A direct experimental comparison between a two dimensional system and a single genuinely one dimensional quantum wire system, inaccessible to conventional far field optical spectroscopy, is enabled by the enhanced spatial resolution. We show that the photoluminescence of a single quantum wire is easily distinguished from that of the surrounding quantum well. Emission from localized centers is shown to dominate the photoluminescence from both wires and wells at low temperatures. A factor of 3 absorption enhancement for these wires compared to the wells is concluded from the photoluminescence excitation data.

  18. Laparoscopic extraction of fractured Kirschner wire from the pelvis

    Directory of Open Access Journals (Sweden)

    Vinaykumar N Thati

    2014-01-01

    Full Text Available Kirschner wire is a sharp stainless steel guide wire commonly used in fixation of fractured bone segments. There are case reports of migrated K wire from the upper limb into the spine and chest, and from the lower limb in to the abdomen and pelvis. Here, we present a case report of accidental intra-operative fracture of K wire during percutaneous femoral nailing for sub-trochanteric fracture of right femur, which migrated in to the pelvis when the orthopaedician tried to retrieve the broken segment of the K wire. This case highlights the use of laparoscopy as minimally invasive surgical option.

  19. Experimentally verified inductance extraction and parameter study for superconductive integrated circuit wires crossing ground plane holes

    International Nuclear Information System (INIS)

    Fourie, Coenrad J; Wetzstein, Olaf; Kunert, Juergen; Meyer, Hans-Georg; Toepfer, Hannes

    2013-01-01

    As the complexity of rapid single flux quantum (RSFQ) circuits increases, both current and power consumption of the circuits become important design criteria. Various new concepts such as inductive biasing for energy efficient RSFQ circuits and inductively coupled RSFQ cells for current recycling have been proposed to overcome increasingly severe design problems. Both of these techniques use ground plane holes to increase the inductance or coupling factor of superconducting integrated circuit wires. New design tools are consequently required to handle the new topographies. One important issue in such circuit design is the accurate calculation of networks of inductances even in the presence of finite holes in the ground plane. We show how a fast network extraction method using InductEx, which is a pre- and post-processor for the magnetoquasistatic field solver FastHenry, is used to calculate the inductances of a set of SQUIDs (superconducting quantum interference devices) with ground plane holes of different sizes. The results are compared to measurements of physical structures fabricated with the IPHT Jena 1 kA cm −2 RSFQ niobium process to verify accuracy. We then do a parameter study and derive empirical equations for fast and useful estimation of the inductance of wires surrounded by ground plane holes. We also investigate practical circuits and show excellent accuracy. (paper)

  20. Behavior of a bundle of fast fuel pins under irradiation

    International Nuclear Information System (INIS)

    Marbach, G.; Millet, P.; Robert, J.; Languille, A.

    1979-01-01

    In the French design of fuel elements for fast reactors, great deformation of pins can bring about interaction with the hexagonal tube through the spacer wires. The change in such bundles is described here when the diameter of the cladding increases and the outcome of this reaction (bending and ovalization of pins) is calculated with a simplified model. It is shown that the results achieved agree well with the experimental observations [fr

  1. USING OF PRESSURE DIES AT RUP «BMZ» FOR HIGH-SPEED WIRE DRAWING IN THE REGIME OF HYDRODYNAMIC FRICTION

    Directory of Open Access Journals (Sweden)

    D. G. Sachava

    2008-01-01

    Full Text Available It is shown that using of forcing dies at RUP «BMZ» for high-speed wire drawing in regime of hydrodynamic friction improves the quality of lubrication, and correspondingly fastness of dies incl. finishing ones is increaswd.

  2. Investigation of dynamics of soft X-ray radiation of mixed-material wire-arrays on S-300 pulsed power generator

    NARCIS (Netherlands)

    Cai, HC; Chernenko, AC; Korolev, VD; Ustroev, GI; Ivanov, MI

    2004-01-01

    The dynamics of radiation spectra of fast Z-pinch plasmas was studied. The experiments were carried out on the S-300 pulsed power machine (4 MA, 0.15 Omega, 100 ns). By means of the polychromator, X-ray spectra of imploding wire arrays were measured in the range of 60 divided by 1500 eV, where the

  3. Irradiation in helical scanner: doses estimation, parameters choice; Irradiation en scanner helicoidal: estimation des doses, choix des parametres

    Energy Technology Data Exchange (ETDEWEB)

    Cordoliani, Y.S.; Boyer, B.; Jouan, E.; Beauvais, H

    2001-07-01

    The new generation of helical scanners improves the diagnosis abilities and the service done to the patients. The rational use allows to give the patients a ratio benefit/risk far better than the almost medical examinations. It is particularly true for over sixty years old aged people, that have a null genetic risk and a practically null carcinogen risk; However, for young adults and children, it is necessary to banish any useless irradiation and limit exposure to the strict necessary for the diagnosis. It is necessary to develop a radiation protection culture, possible by the radiation doses index display and doses benchmarks knowledge. (N.C.)

  4. Enhanced THz guiding properties of curved two-wire lines.

    Science.gov (United States)

    Zha, Jingshu; Kim, Geun Ju; Jeon, Tae-In

    2016-03-21

    We present experimental and simulation studies of enhanced terahertz (THz) guiding properties of curved two-wire lines for several surface conditions. When a THz-wave propagates through curved two-wire lines, a rough wire surface with dielectric coating contributes to a lower bending loss compared to a smooth or rough wire surface without coating. Dielectric coating and rough surface confine the THz field to the wire surface making the bending loss low. The guiding property at a curve depth of 30 mm of a rough wire surface with 25-μm-thick coating is improved by 34% compared to that of a smooth wire without coating. Furthermore, computer simulation technology (CST) software visually shows the bending loss as same as the experimental studies.

  5. Operation of the preclinical head scanner for proton CT

    Energy Technology Data Exchange (ETDEWEB)

    Sadrozinski, H.F.-W., E-mail: hartmut@ucsc.edu [SCIPP, U.C. Santa Cruz, Santa Cruz, CA 95064 (United States); Geoghegan, T.; Harvey, E.; Johnson, R.P.; Plautz, T.E.; Zatserklyaniy, A. [SCIPP, U.C. Santa Cruz, Santa Cruz, CA 95064 (United States); Bashkirov, V.; Hurley, R.F.; Piersimoni, P.; Schulte, R.W. [Division of Radiation Research, Loma Linda University, Loma Linda, CA 92354 (United States); Karbasi, P.; Schubert, K.E.; Schultze, B. [School of Engineering and Computer Science, Baylor University, Waco, TX 76798 (United States); Giacometti, V. [Center for Medical Radiation Physics, University of Wollongong, NSW (Australia)

    2016-09-21

    We report on the operation and performance tests of a preclinical head scanner developed for proton computed tomography (pCT). After extensive preclinical testing, pCT is intended to be employed in support of proton therapy treatment planning and pre-treatment verification in patients undergoing particle-beam therapy. In order to assess the performance of the scanner, we have performed CT scans with 200 MeV protons from both the synchrotron of the Loma Linda University Medical Center (LLUMC) and the cyclotron of the Northwestern Medicine Chicago Proton Center (NMCPC). The very high sustained rate of data acquisition, exceeding one million protons per second, allowed a full 360° scan to be completed in less than 7 min. The reconstruction of various phantoms verified accurate reconstruction of the proton relative stopping power (RSP) and the spatial resolution in a variety of materials. The dose for an image with better than 1% uncertainty in the RSP is found to be close to 1 mGy.

  6. Acoustic noise characteristics of a 4 Telsa MRI scanner.

    Science.gov (United States)

    More, Shashikant R; Lim, Teik C; Li, Mingfeng; Holland, Christy K; Boyce, Suzanne E; Lee, Jing-Huei

    2006-03-01

    To quantify the acoustic noise characteristics of a 4 Tesla MRI scanner, and determine the effects of structural acoustics and gradient pulse excitations on the sound field so that feasible noise control measures can be developed. Acoustic noise emissions were measured in the ear and mouth locations of a typical adult. The sound pressure measurements were acquired simultaneously with the electrical current signals of the gradient pulses. Two forms of gradient waveforms (impulsive and operating pulses) were studied. The sound pressure levels (SPLs) emitted by the MRI scanner operating in echo-planar imaging (EPI) mode were in the range of 120-130 decibels. Three types of sound pressure responses were observed in the EPI sequences: 1) harmonic, 2) nonharmonic, and 3) broadband. The frequency-encoding gradient pulses were the most dominant and produced generally odd-number harmonics and nonharmonics. The phase-encoding gradient pulses generated mostly even-number harmonics, and the slice-selection gradient pulses produced primarily a broadband spectrum. The operating condition acoustic spectrum can be predicted from the magnet-structural acoustic transfer functions, which are independent of imaging sequences. This finding is encouraging because it shows that it is possible to treat such noises with an active noise control application. (c) 2006 Wiley-Liss, Inc.

  7. Daily quality controls analysis of a CT scanner simulator

    International Nuclear Information System (INIS)

    Vasques, Maira Milanelo; Santos, Gabriela R.; Furnari, Laura

    2016-01-01

    With the increasing technological developments, radiotherapy practices, which allow for better involvement of the tumor with the required therapeutic dose and minimize the complications of normal tissues, have become reality in several Radiotherapy services. The use of these resources in turn, was only possible due to the progress made in planning based on digital volumetric images of good quality, such as computed tomography (CT), which allow the correct delimitation of the tumor volume and critical structures. Specific tests for quality control in a CT scanner used in radiotherapy, named CT simulator, should be applied as part of the institutional Quality Assurance Program. This study presents the methodology used in the Instituto de Radiologia do Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo (HCFMUSP) for daily testing of the CT scanner simulator and the results obtained throughout more than two years. The experience gained in the period conducted showed that the tests are easy to perform and can be done in a few minutes by a trained professional. Data analysis showed good reproducibility, which allowed the tests could be performed less frequently, after 16 months of data collection. (author)

  8. Scanners and drillers: Characterizing expert visual search through volumetric images

    Science.gov (United States)

    Drew, Trafton; Vo, Melissa Le-Hoa; Olwal, Alex; Jacobson, Francine; Seltzer, Steven E.; Wolfe, Jeremy M.

    2013-01-01

    Modern imaging methods like computed tomography (CT) generate 3-D volumes of image data. How do radiologists search through such images? Are certain strategies more efficient? Although there is a large literature devoted to understanding search in 2-D, relatively little is known about search in volumetric space. In recent years, with the ever-increasing popularity of volumetric medical imaging, this question has taken on increased importance as we try to understand, and ultimately reduce, errors in diagnostic radiology. In the current study, we asked 24 radiologists to search chest CTs for lung nodules that could indicate lung cancer. To search, radiologists scrolled up and down through a “stack” of 2-D chest CT “slices.” At each moment, we tracked eye movements in the 2-D image plane and coregistered eye position with the current slice. We used these data to create a 3-D representation of the eye movements through the image volume. Radiologists tended to follow one of two dominant search strategies: “drilling” and “scanning.” Drillers restrict eye movements to a small region of the lung while quickly scrolling through depth. Scanners move more slowly through depth and search an entire level of the lung before moving on to the next level in depth. Driller performance was superior to the scanners on a variety of metrics, including lung nodule detection rate, percentage of the lung covered, and the percentage of search errors where a nodule was never fixated. PMID:23922445

  9. Label-free tissue scanner for colorectal cancer screening

    Science.gov (United States)

    Kandel, Mikhail E.; Sridharan, Shamira; Liang, Jon; Luo, Zelun; Han, Kevin; Macias, Virgilia; Shah, Anish; Patel, Roshan; Tangella, Krishnarao; Kajdacsy-Balla, Andre; Guzman, Grace; Popescu, Gabriel

    2017-06-01

    The current practice of surgical pathology relies on external contrast agents to reveal tissue architecture, which is then qualitatively examined by a trained pathologist. The diagnosis is based on the comparison with standardized empirical, qualitative assessments of limited objectivity. We propose an approach to pathology based on interferometric imaging of "unstained" biopsies, which provides unique capabilities for quantitative diagnosis and automation. We developed a label-free tissue scanner based on "quantitative phase imaging," which maps out optical path length at each point in the field of view and, thus, yields images that are sensitive to the "nanoscale" tissue architecture. Unlike analysis of stained tissue, which is qualitative in nature and affected by color balance, staining strength and imaging conditions, optical path length measurements are intrinsically quantitative, i.e., images can be compared across different instruments and clinical sites. These critical features allow us to automate the diagnosis process. We paired our interferometric optical system with highly parallelized, dedicated software algorithms for data acquisition, allowing us to image at a throughput comparable to that of commercial tissue scanners while maintaining the nanoscale sensitivity to morphology. Based on the measured phase information, we implemented software tools for autofocusing during imaging, as well as image archiving and data access. To illustrate the potential of our technology for large volume pathology screening, we established an "intrinsic marker" for colorectal disease that detects tissue with dysplasia or colorectal cancer and flags specific areas for further examination, potentially improving the efficiency of existing pathology workflows.

  10. Evaluation of ischemic heart disease on a 1.5 Tesla scanner. Combined first-pass perfusion and viability study

    International Nuclear Information System (INIS)

    Okuda, Shigeo; Tanimoto, Akihiro; Satoh, Toru; Hashimoto, Jun; Shinmoto, Hiroshi; Higuchi, Nobuya; Kuribayashi, Sachio

    2005-01-01

    We implemented a fast gradient echo (GRE) sequence with an echo-planar imaging (EPI) read-out (FGRE-ET) to conduct myocardial perfusion studies on a conventional scanner. The accuracy of combined perfusion and viability studies is evaluated in comparison with coronary angiography (CAG). We enrolled 33 patients suspected of having coronary artery disease in this study. Short-axis perfusion images of the left ventricles were acquired following intravenous bolus injection of gadolinium-DTPA (0.05 mml/kg), both after myocardial loading by dipyridamole (0.56 mg/kg) and at rest. Viability studies were obtained using an inversion-recovery FGRE sequence. Radiologists performed blinded film readings. The findings with perfusion and the viability studies were compared with CAG on a segment-to-segment basis corresponding to the coronary arteries' territories. Stenosis equal to or greater than 75% in diameter was considered significant on CAG. The results were also compared with single photon emission computed tomography (SPECT) in 23 patients. The combination of perfusion and viability studies showed 85.7% sensitivity, 88.9% specificity, and 87.2% accuracy in comparison with CAG. SPECT revealed respective rates of 71.7%, 78.3%, and 73.9% in 23 patients of this group. Myocardial perfusion studies using EGRE-ET were feasible and accurate, even on a conventional scanner. (author)

  11. Dynamic Sensor Interrogation Using Wavelength-Swept Laser with a Polygon-Scanner-Based Wavelength Filter

    Directory of Open Access Journals (Sweden)

    Kyung Hyun Park

    2013-07-01

    Full Text Available We report a high-speed (~2 kHz dynamic multiplexed fiber Bragg grating (FBG sensor interrogation using a wavelength-swept laser (WSL with a polygon-scanner-based wavelength filter. The scanning frequency of the WSL is 18 kHz, and the 10 dB scanning bandwidth is more than 90 nm around a center wavelength of 1,540 nm. The output from the WSL is coupled into the multiplexed FBG array, which consists of five FBGs. The reflected Bragg wavelengths of the FBGs are 1,532.02 nm, 1,537.84 nm, 1,543.48 nm, 1,547.98 nm, and 1,553.06 nm, respectively. A dynamic periodic strain ranging from 500 Hz to 2 kHz is applied to one of the multiplexed FBGs, which is fixed on the stage of the piezoelectric transducer stack. Good dynamic performance of the FBGs and recording of their fast Fourier transform spectra have been successfully achieved with a measuring speed of 18 kHz. The signal-to-noise ratio and the bandwidth over the whole frequency span are determined to be more than 30 dB and around 10 Hz, respectively. We successfully obtained a real-time measurement of the abrupt change of the periodic strain. The dynamic FBG sensor interrogation system can be read out with a WSL for high-speed and high-sensitivity real-time measurement.

  12. Processing optimization with parallel computing for the J-PET scanner

    Directory of Open Access Journals (Sweden)

    Krzemień Wojciech

    2015-12-01

    Full Text Available The Jagiellonian Positron Emission Tomograph (J-PET collaboration is developing a prototype time of flight (TOF-positron emission tomograph (PET detector based on long polymer scintillators. This novel approach exploits the excellent time properties of the plastic scintillators, which permit very precise time measurements. The very fast field programmable gate array (FPGA-based front-end electronics and the data acquisition system, as well as low- and high-level reconstruction algorithms were specially developed to be used with the J-PET scanner. The TOF-PET data processing and reconstruction are time and resource demanding operations, especially in the case of a large acceptance detector that works in triggerless data acquisition mode. In this article, we discuss the parallel computing methods applied to optimize the data processing for the J-PET detector. We begin with general concepts of parallel computing and then we discuss several applications of those techniques in the J-PET data processing.

  13. Evaluation of New Inorganic Scintillators for Application in a Prototype Small Animal PET Scanner

    CERN Document Server

    Kuntner, C

    2003-01-01

    In the study of new pharmaceuticals as well as brain and genetic research, Positron Emission Tomography (PET) is a useful method. It has also recently entered the clinical domain in cardiology and particularly in oncology. Small animals such as mice, are often used to validate sophisticated models of human disease. High spatial resolution PET instrumentation is therefore necessary due to the reduced dimensions of the organs. Inorganic scintillators are employed in most of the diagnostic imaging devices. The ultimate performance of the PET scanner is tightly bound to the scintillation properties of the crystals. In the last years there has been an effort to develop new scintillating materials characterized by high light output, high detection efficiency and fast decay time. The most studied systems are mainly Ce3+-doped crystals such as LSO:Ce, YAP:Ce, LuAP:Ce, and recently also mixed Lux(RE3+)1-xAlO3:Ce crystals. These crystals are very attractive for medical application because of their high density (with th...

  14. Heat Transfer Analysis in Wire Bundles for Aerospace Vehicles

    Science.gov (United States)

    Rickman, S. L.; Iamello, C. J.

    2016-01-01

    Design of wiring for aerospace vehicles relies on an understanding of "ampacity" which refers to the current carrying capacity of wires, either, individually or in wire bundles. Designers rely on standards to derate allowable current flow to prevent exceedance of wire temperature limits due to resistive heat dissipation within the wires or wire bundles. These standards often add considerable margin and are based on empirical data. Commercial providers are taking an aggressive approach to wire sizing which challenges the conventional wisdom of the established standards. Thermal modelling of wire bundles may offer significant mass reduction in a system if the technique can be generalized to produce reliable temperature predictions for arbitrary bundle configurations. Thermal analysis has been applied to the problem of wire bundles wherein any or all of the wires within the bundle may carry current. Wire bundles present analytical challenges because the heat transfer path from conductors internal to the bundle is tortuous, relying on internal radiation and thermal interface conductance to move the heat from within the bundle to the external jacket where it can be carried away by convective and radiative heat transfer. The problem is further complicated by the dependence of wire electrical resistivity on temperature. Reduced heat transfer out of the bundle leads to higher conductor temperatures and, hence, increased resistive heat dissipation. Development of a generalized wire bundle thermal model is presented and compared with test data. The steady state heat balance for a single wire is derived and extended to the bundle configuration. The generalized model includes the effects of temperature varying resistance, internal radiation and thermal interface conductance, external radiation and temperature varying convective relief from the free surface. The sensitivity of the response to uncertainties in key model parameters is explored using Monte Carlo analysis.

  15. Disorder and Interaction Effects in Quantum Wires

    International Nuclear Information System (INIS)

    Smith, L W; Ritchie, D A; Farrer, I; Griffiths, J P; Jones, G A C; Thomas, K J; Pepper, M

    2012-01-01

    We present conductance measurements of quasi-one-dimensional quantum wires affected by random disorder in a GaAs/AlGaAs heterostructure. In addition to quantised conductance plateaux, we observe structure superimposed on the conductance characteristics when the channel is wide and the density is low. Magnetic field and temperature are varied to characterize the conductance features which depend on the lateral position of the 1D channel formed in a split-gate device. Our results suggest that there is enhanced backscattering in the wide channel limit, which gives rise to quantum interference effects. When the wires are free of disorder and wide, the confinement is weak so that the mutual repulsion of the electrons forces a single row to split into two. The relationship of this topological change to the disorder in the system will be discussed.

  16. Superconducting wire turns to electrical power

    CERN Document Server

    Sargent, P

    2003-01-01

    Two years after the discovery that magnesium diboride is a superconductor, engineers and entrepreneurs are keen to transform its properties into profit. The discovery of superconductivity at 39 K in the metallic compound magnesium diboride two years ago created quite a stir. Since then, physicists and chemists have come a long way in understanding the curious set of circumstances that lead to such a high critical temperature in this widely available material. At the same time, metallurgists, engineers and entrepreneurs have been focusing on the commercial potential of magnesium diboride as superconducting wire, which was the subject of a one-day meeting in Cambridge, UK, in April. Superconducting wire made from magnesium diboride could make 'second- generation' electrical machines commercially viable. (U.K.)

  17. Neutron refraction by cylindrical metal wires

    International Nuclear Information System (INIS)

    Plomp, J.; Barker, J.G.; Haan, V.O. de; Bouwman, W.G.; Well, A.A. van

    2007-01-01

    Undesired Small-Angle Neutron Scattering (SANS) from interior features of an object can be minimised by reducing the sample thickness. However, refraction effects produced by the exterior shape of the object depend upon the scattering cross-section and not on the thickness of the object. In the field of polarised neutrons a wire coil is often used to manipulate the polarisation vector of the neutron. In this paper, we show that the cylindrical shape of the wire together with the refractive index introduces an angular distribution in the neutron beam. This can be observed in instrumentation sensitive to SANS. We show results measured on three different SANS instruments: Ultra Small-Angle Neutrons Scattering (USANS), Spin-Echo Small-Angle Neutron Scattering (SESANS) and a Time-of-Flight (TOF) SESANS. These results are all in good agreement with the theory of refraction

  18. Neutron refraction by cylindrical metal wires

    Energy Technology Data Exchange (ETDEWEB)

    Plomp, J. [Faculty of Applied Sciences, Delft University of Technology, Delft (Netherlands)]. E-mail: j.plomp@tudelft.nl; Barker, J.G. [NIST Center for Neutron Research, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Haan, V.O. de [Faculty of Applied Sciences, Delft University of Technology, Delft (Netherlands); Bouwman, W.G. [Faculty of Applied Sciences, Delft University of Technology, Delft (Netherlands); Well, A.A. van [Faculty of Applied Sciences, Delft University of Technology, Delft (Netherlands)

    2007-05-01

    Undesired Small-Angle Neutron Scattering (SANS) from interior features of an object can be minimised by reducing the sample thickness. However, refraction effects produced by the exterior shape of the object depend upon the scattering cross-section and not on the thickness of the object. In the field of polarised neutrons a wire coil is often used to manipulate the polarisation vector of the neutron. In this paper, we show that the cylindrical shape of the wire together with the refractive index introduces an angular distribution in the neutron beam. This can be observed in instrumentation sensitive to SANS. We show results measured on three different SANS instruments: Ultra Small-Angle Neutrons Scattering (USANS), Spin-Echo Small-Angle Neutron Scattering (SESANS) and a Time-of-Flight (TOF) SESANS. These results are all in good agreement with the theory of refraction.

  19. A high speed X-ray computed tomography scanner for multipurpose flow visualization and measurement

    International Nuclear Information System (INIS)

    Hori, K.; Kawanishi, K.; Hamamura, H.; Ochi, M.; Akai, M.

    2004-01-01

    The development of a high-speed X-ray computed tomography (CT) scanner has been performed in this study. The object of interest is in a transient or unsettled state, which makes the conventional CT scanner inappropriate. This X-ray CT system uses the concept of electronic switching of electron beams for X-ray generation to increase scanning speed. A continuous operation X-ray CT scanner sampling at about 4 milliseconds scanning rate has already been developed and applied for air-water two-phase flow measurement. The feasibility and the excellent performance of this CT scanner system are demonstrated and confirmed. (author)

  20. Imaging system models for small-bore DOI-PET scanners

    International Nuclear Information System (INIS)

    Takahashi, Hisashi; Kobayashi, Tetsuya; Yamaya, Taiga; Murayama, Hideo; Kitamura, Keishi; Hasegawa, Tomoyuki; Suga, Mikio

    2006-01-01

    Depth-of-interaction (DOI) information, which improves resolution uniformity in the field of view (FOV), is expected to lead to high-sensitivity PET scanners with small-bore detector rings. We are developing small-bore PET scanners with DOI detectors arranged in hexagonal or overlapped tetragonal patterns for small animal imaging or mammography. It is necessary to optimize the imaging system model because these scanners exhibit irregular detector sampling. In this work, we compared two imaging system models: (a) a parallel sub-LOR model in which the detector response functions (DRFs) are assumed to be uniform along the line of responses (LORs) and (b) a sub-crystal model in which each crystal is divided into a set of smaller volumes. These two models were applied to the overlapped tetragonal scanner (FOV 38.1 mm in diameter) and the hexagonal scanner (FOV 85.2 mm in diameter) simulated by GATE. We showed that the resolution non-uniformity of system model (b) was improved by 40% compared with that of system model (a) in the overlapped tetragonal scanner and that the resolution non-uniformity of system model (a) was improved by 18% compared with that of system model (b) in the hexagonal scanner. These results indicate that system model (b) should be applied to the overlapped tetragonal scanner and system model (a) should be applied to the hexagonal scanner. (author)

  1. From barbed wire to radar traps

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    Several million DM are required already to protect the building sites of power plants. From the very beginning concrete, wood, and barbed wire are used to make a protective wall against intruders, or in official German, 'unauthorized persons'. This expensive provisional set-up is later supplanted by electronic alarm and safety systems. A review of available systems helps to give a picture of power plant protection. (orig.) 891 HP [de

  2. Visible emission from exploding wire in water

    Czech Academy of Sciences Publication Activity Database

    Šimek, Milan; Prukner, Václav; Schmidt, Jiří; Koláček, Karel; Štraus, Jaroslav; Frolov, Oleksandr

    2007-01-01

    Roč. 53, č. 10 (2007), s. 53-53 ISSN 0003-0503. [The 61st Annual Gaseous Electronic Conference. Dallas, Texas , 13.10.2008-17.10.2008] R&D Projects: GA ČR GA202/06/1324 Institutional research plan: CEZ:AV0Z20430508 Keywords : Exploding wire * emission Subject RIV: BL - Plasma and Gas Discharge Physics

  3. Wire chambers with their magnetostrictive readout

    CERN Multimedia

    1974-01-01

    This set of wire chamber planes shaped as a cylinder sector was installed inside the magnet of a polarized spin target modified to allow as well momentum analysis of the produced particles. The experiment (S126) was set up by the CERN-Trieste Collaboration in the PS beam m9 to measure spin effects in the associated production of of a positive kaon and a positive Sigma by interaction of a positive pion with polarized protons.

  4. Inverter design for four-wire microgrids

    OpenAIRE

    Heredero Peris, Daniel; Pagès Giménez, Marc; Montesinos Miracle, Daniel

    2015-01-01

    This paper presents a PQ four quadrant four-wire three-phase inverter for microgrids integration. The inverter is based in two full-bridge IGBT modules connected in a three-phase configuration plus a threephase parallelized neutral branch. This topology is galvanically isolated through a single-phase transformer bank. The converter operates as a non-ideal voltage-controlled voltage source inverter under AC droop strategy with hot-swap capability based on a dynamic virtual impedance.

  5. METHOD OF MAKING WIRE FUEL ELEMENTS

    Science.gov (United States)

    Zambrow, J.L.

    1960-08-01

    A method is given for making a nuclear reactor fuel element in the form of a uranium-bearing wire clad with zirconium. A uranium bar is enclosed in a zirconium sheath which is coated with an oxide of magnesium, beryllium, or zirconium. The sheathed bar is then placed in a steel tube and reduced to the desired diameter by swaging at 800 to 900 deg C, after which the steel and oxide are removed.

  6. Fast Registration Method for Point Clouds Using the Image Information

    Directory of Open Access Journals (Sweden)

    WANG Ruiyan

    2016-01-01

    Full Text Available On the existing laser scanners, there usually is a coaxial camera, which could capture images in the scanning site. For the laser scanners with a coaxial camera, we propose a fast registration method using the image information. Unlike the traditional registration methods that computing the rotation and translation simultaneously, our method calculates them individually. The rotation transformation between the point clouds is obtained by the knowledge of the vision geometry and the image information, while their translation is acquired by our improved ICP algorithm. In the improved ICP algorithm, only the translation vector is updated iteratively, whose input is the point clouds that removing the rotation transformation. Experimental results show that the rotation matrix obtained by the images has a high accuracy. In addition, compared with the traditional ICP algorithm, our algorithm converges faster and is easier to fall into the global optimum.

  7. Numerical Investigation of Corrugated Wire Mesh Laminate

    Directory of Open Access Journals (Sweden)

    Jeongho Choi

    2013-01-01

    Full Text Available The aim of this work is to develop a numerical model of Corrugated Wire Mesh Laminate (CWML capturing all its complexities such as nonlinear material properties, nonlinear geometry and large deformation behaviour, and frictional behaviour. Development of such a model will facilitate numerical simulation of the mechanical behaviour of the wire mesh structure under various types of loading as well as the variation of the CWML configuration parameters to tailor its mechanical properties to suit the intended application. Starting with a single strand truss model consisting of four waves with a bilinear stress-strain model to represent the plastic behaviour of stainless steel, the finite element model is gradually built up to study single-layer structures with 18 strands of corrugated wire meshes consistency and double- and quadruple-layered laminates with alternating crossply orientations. The compressive behaviour of the CWML model is simulated using contact elements to model friction and is compared to the load-deflection behaviour determined experimentally in uniaxial compression tests. The numerical model of the CWML is then employed to conduct the aim of establishing the upper and lower bounds of stiffness and load capacity achievable by such structures.

  8. Contact conductance between graphene and quantum wires

    International Nuclear Information System (INIS)

    Li Haidong; Zheng Yisong

    2009-01-01

    The contact conductance between graphene and two quantum wires which serve as the leads to connect graphene and electron reservoirs is theoretically studied. Our investigation indicates that the contact conductance depends sensitively on the graphene-lead coupling configuration. When each quantum wire couples solely to one carbon atom, the contact conductance vanishes at the Dirac point if the two carbon atoms coupling to the two leads belong to the same sublattice of graphene. We find that such a feature arises from the chirality of the Dirac electron in graphene. Such a chirality associated with conductance zero disappears when a quantum wire couples to multiple carbon atoms. The general result irrelevant to the coupling configuration is that the contact conductance decays rapidly with the increase of the distance between the two leads. In addition, in the weak graphene-lead coupling limit, when the distance between the two leads is much larger than the size of the graphene-lead contact areas and the incident electron energy is close to the Dirac point, the contact conductance is proportional to the square of the product of the two graphene-lead contact areas, and inversely proportional to the square of the distance between the two leads

  9. Results of the Fermilab wire production program

    International Nuclear Information System (INIS)

    Strauss, B.P.; Remsbottom, R.H.; Reardon, P.J.; Curtis, C.W.; McDonald, W.K.

    1976-01-01

    In examining the various schedules of wire drawing and heat treating, the Critchlow type of schedule provided the highest and most uniform data from billet to billet. It consists of a long anneal at 400 +- 20 0 C at a cold work point giving about 99 percent reduction in area from the extrusion size. Several quick copper anneals at 300 0 C may be interspersed to aid in fabrication. A final anneal at finished size both peaks up the resistivity ratio of the copper as well as the critical current of the alloy by moving dislocations to subcell walls. Using this method, critical currents of 1.7 x 10 5 A/cm 2 could be maintained in all billets. The copper cladding and sinking method looks promising and should save production costs. In spite of this, it was important to attain good packing density in the billets to assure uniform filament pattern and reduce breakage in wire drawing. Overall, a procedure was found for fabricating wire in large production lots that would be acceptable for constructing dipole magnets. It is felt that this method could be peaked up with time

  10. Reliability of the wire drawing dies

    International Nuclear Information System (INIS)

    Sheikh, A.K.; Khany, S.E.

    1993-01-01

    A wear based model is proposed for the dies used in wire drawing process. Using this wear model, it is possible to predict life of the die corresponding to a wear limit criterion. Since various quantities in the model are random in nature the resulting die life will also be random quantity characterized by an appropriate distribution. Using a probabilistic characterization of the parameters of the predictive model, Monte Carlo simulations were conducted to establish the die life distribution. To asses the sensitivity of life distribution with respect to various contributing variables (parameters), the simulation runs were conducted at different levels of these variables (parameters). It is shown that wire drawing die life is Weibull distributed. To compare the simulated results with actual time to failure, data of dies was obtained from a large wire drawing company and was compared with corresponding scenario generated by Monte Carlo simulation. Results obtained by Monte Carlo simulations were very close to the actual time to failure data. (author)

  11. NA48: Wiring up for Change

    CERN Multimedia

    2001-01-01

    The NA48 Collaboration is rebuilding its drift chambers ready for the experiment to start up again this coming July. An intricate task involving the soldering of over 24,000 wires! The future of the NA48 experiment is coming right down to the wire, that is, the wires which the Collaboration is installing in the clean room of Hall 887 on the Prévessin site. Six days a week, technicians are working in shifts to rebuild the experiment's drift chambers. The original chambers were damaged when a section of a vacuum tube imploded at the end of 1999. A year ago, CERN gave the green light for this essential part of the spectrometer to be rebuilt, so the NA48 experiment, which studies CP violation (see box), still has a bright future ahead of it. Three years of data-taking ahead The NA48 experiment aims to penetrate the secrets of CP (Charge Parity) violation. Charge and parity are two parameters which distinguish a particle from an antiparticle. In other words, an electron possesses a negative electric ...

  12. Thermosonic wire bonding of gold wire onto copper pad using the saturated interfacial phenomena

    Science.gov (United States)

    Jeng, Yeau-Ren; Aoh, Jong-Hing; Wang, Chang-Ming

    2001-12-01

    Copper has been used to replace conventional aluminium interconnection to improve the performance of deep submicron integrated circuits. This study used the saturated interfacial phenomena found in thermosonic ball bonding of gold wire onto aluminium pad to investigate thermosonic ball bonding of gold wire onto copper pad. The effects of preheat temperatures and ultrasonic powers on the bonding force were investigated by using a thermosonic bonding machine and a shear tester. This work shows that under proper preheat temperatures, the bonding force of thermosonic wire bonding can be explained based on interfacial microcontact phenomena such as energy intensity, interfacial temperature and real contact area. It is clearly shown that as the energy intensity is increased, the shear force increases, reaches a maximum, and then decreases. After saturation, i.e. the establishment of maximum atomic bonding, any type of additional energy input will damage the bonding, decreasing the shear force. If the preheat temperature is not within the proper range, the interfacial saturation phenomenon does not exist. For a preload of 0.5 N and a welding time of 15 ms in thermosonic wire bonding of gold wire onto copper pads, a maximum shear force of about 0.33 N is found where the interfacial energy intensity equals 1.8×106 J m-2 for preheat temperatures of 150°C and 170°C. Moreover, the corresponding optimal ultrasonic power is about 110 units.

  13. The accuracy of the CAD system using intraoral and extraoral scanners for designing of fixed dental prostheses.

    Science.gov (United States)

    Shimizu, Sakura; Shinya, Akikazu; Kuroda, Soichi; Gomi, Harunori

    2017-07-26

    The accuracy of prostheses affects clinical success and is, in turn, affected by the accuracy of the scanner and CAD programs. Thus, their accuracy is important. The first aim of this study was to evaluate the accuracy of an intraoral scanner with active triangulation (Cerec Omnicam), an intraoral scanner with a confocal laser (3Shape Trios), and an extraoral scanner with active triangulation (D810). The second aim of this study was to compare the accuracy of the digital crowns designed with two different scanner/CAD combinations. The accuracy of the intraoral scanners and extraoral scanner was clinically acceptable. Marginal and internal fit of the digital crowns fabricated using the intraoral scanner and CAD programs were inferior to those fabricated using the extraoral scanner and CAD programs.

  14. Multi-spectral optical scanners for commercial earth observation missions

    Science.gov (United States)

    Schröter, Karin; Engel, Wolfgang; Berndt, Klaus

    2017-11-01

    In recent years, a number of commercial Earth observation missions have been initiated with the aim to gather data in the visible and near-infrared wavelength range. Some of these missions aim at medium resolution (5 to 10 m) multi-spectral imaging with the special background of daily revisiting. Typical applications aim at monitoring of farming area for growth control and harvest prediction, irrigation control, or disaster monitoring such as hail damage in farming, or flood survey. In order to arrive at profitable business plans for such missions, it is mandatory to establish the space segment, i.e. the spacecraft with their opto -electronic payloads, at minimum cost while guaranteeing maximum reliability for mission success. As multiple spacecraft are required for daily revisiting, the solutions are typically based on micro-satellites. This paper presents designs for multi-spectral opto-electric scanners for this type of missions. These designs are drive n by minimum mass and power budgets of microsatellites, and the need for minimum cost. As a consequence, it is mandatory to arrive at thermally robust, compact telescope designs. The paper gives a comparison between refractive, catadioptric, and TMA optics. For mirror designs, aluminium and Zerodur mirror technologies are briefly discussed. State-of-the art focal plane designs are presented. The paper also addresses the choice of detector technologies such as CCDs and CMOS Active Pixel Sensors. The electronics of the multi-spectral scanners represent the main design driver regarding power consumption, reliability, and (most often) cost. It can be subdivided into the detector drive electronics, analog and digital data processing chains, the data mass memory unit, formatting and down - linking units, payload control electronics, and local power supply. The paper gives overviews and trade-offs between data compression strategies and electronics solutions, mass memory unit designs, and data formatting approaches

  15. CT Angiography of Peripheral Arterial Disease by 256-Slice Scanner: Accuracy, Advantages and Disadvantages Compared to Digital Subtraction Angiography.

    Science.gov (United States)

    Mishra, Atul; Jain, Narendra; Bhagwat, Anand

    2017-07-01

    Peripheral arterial occlusive disease (PAOD) may cause disabling claudication or critical limb ischemia. Multidetector computed tomography (CT) technology has evolved to the level of 256-slice CT scanners which has significantly improved the spatial and temporal resolution of the images. This has provided the capability of chasing the contrast bolus at a fast speed enabling angiographic imaging of long segments of the body. These images can be reconstructed in various planes and various modes for detailed analysis of the peripheral vascular diseases which helps in making treatment decision. The aim of this retrospective study was to compare the CT angiograms (CTAs) of all cases of PAOD done by 256-slice CT scanner at a tertiary care vascular center and comparing these images with the digital subtraction angiograms (DSAs) of these patients. The retrospective study included 53 patients who underwent both CTA and DSA at our center over a period of 3 years from March 2013 to March 2016. The CTA showed high sensitivity (93%) and specificity (92.7%) for overall assessment of degree of stenosis in a vascular segment in cases of aortic and lower limb occlusive disease. The assessment of lesions of infrapopliteal segment was comparatively inferior (sensitivity 91.6%, accuracy 73.3%, and positive predictive value 78.5%), more so in the presence of significant calcification. The advantages of CTA were its noninvasive nature, ability to image large area of body, almost no adverse effects to the patients, and better assessment of vessel wall disease. However, the CTA assessment of collaterals was inferior with a sensitivity of only 62.7% as compared to DSA. Overall, 256-slice CTA provides fast and accurate imaging of vascular tree which can restrict DSA only in few selected cases as a problem-solving tool where clinico-radiological mismatch is present.

  16. Optimization of the Single Staggered Wire and Tube Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Arsana I Made

    2016-01-01

    Full Text Available Wire and tube heat exchanger consists of a coiled tube, and wire is welded on the two sides of it in normal direction of the tube. Generally,wire and tube heat exchanger uses inline wire arrangement between the two sides, whereas in this study, it used staggered wire arrangement that reduces the restriction of convection heat transfer. This study performed the optimization of single staggered wire and tube heat exchanger to increase the capacity and reduce the mass of the heat exchanger. Optimization was conducted with the Hooke-Jeeves method, which aims to optimize the geometry of the heat exchanger, especially on the diameter (dw and the distance between wires (pw. The model developed to present heat transfer correlations on single staggered wire and tube heat exchanger was valid. The maximum optimization factor obtained when the diameter wire was 0.9 mm and the distance between wires (pw was 11 mm with the fref value = 1.5837. It means that the optimized design only using mass of 59,10 % and could transfer heat about 98,5 % from the basis design.

  17. Applications of surface analysis in the wire industry

    Science.gov (United States)

    Stout, David A.

    The quality of wire is judged not only by its physical properties such as tensile strength and fatigue resistance, but also by its surface finish. The surface roughness, oxide formation, cleanliness, and plating homogeneity and porosity are just a few of the surface properties than can influence the performance of a wire product. Coupled to this is the large amount of surface area generated in drawing wire. For example, a ten pound spool holds nine miles of 0.006″ diameter stainless steel wire. For these reasons surface analysis has become important both to the manufacturer and consumer of wire products. When surface analysis equipment such as AES, ESCA, and SIMS was first becoming commercially available in the late sixties and early seventies, the wire industry was beginning to enter a phase of technological development for many of its products. Wire manufacturers and users began using surface analysis to investigate such topics as adhesion of brass plated automobile tire cord to rubber and diffusion of layered deposits. Examples of surface analysis used for process control, problem solving, and project development include discoloration problems on stainless steel wire, welding problems with composite wires, diffusion formed brass coatings, and diffusion problems with solder coated and Cu plated steel wire.

  18. A new design of wire locators for drift tubes

    CERN Document Server

    Ilgner, C

    2004-01-01

    Every position-sensitive wire detector needs to solve the problem of wire positioning with a defined accuracy all over its sensitive volume. In particular, thin-walled drift tubes ("straws"), which are currently being attached to large detector units of several tens of square meters of surface, need to be equipped with wire locators along their signal wires. A wire locator has been developed together with an insertion device, especially for medium-sized drift tube systems, which significantly reduces the production time and avoids the danger of applying epoxy glue to the signal wire. The wire locator is being inserted in one single time-saving production step together with the signal wire itself. The proposed design is being compared to the rigid wire locators in use in the COMPASS straw tracking system at CERN. The investigation comprises both wire- centering capability and influence on the efficiency of adjacent detector regions, demonstrating the competitive performance of the proposed new system. Its suff...

  19. On fast iterative mapping algorithms for stripe based coarse-grained reconfigurable architectures

    Science.gov (United States)

    Mehta, Gayatri; Patel, Krunalkumar; Pollard, Nancy S.

    2015-01-01

    Reconfigurable devices have potential for great flexibility/efficiency, but mapping algorithms onto these architectures is a long-standing challenge. This paper addresses this challenge for stripe based coarse-grained reconfigurable architectures (CGRAs) by drawing on insights from graph drawing. We adapt fast, iterative algorithms from hierarchical graph drawing to the problem of mapping to stripe based architectures. We find that global sifting is 98 times as fast as simulated annealing and produces very compact designs with 17% less area on average, at a cost of 5% greater wire length. Interleaving iterations of Sugiyama and global sifting is 40 times as fast as simulated annealing and achieves somewhat more compact designs with 1.8% less area on average, at a cost of only 1% greater wire length. These solutions can enable fast design space exploration, rapid performance testing, and flexible programming of CGRAs "in the field."

  20. WIRELESS TENSION BAND WIRING FOR OLECRANON FRACTURES. Case Series.

    Science.gov (United States)

    Roukoz, Sami; Bayoud, Wael

    2016-01-01

    This retrospective study evaluates the results of wireless tension band wire (WTBW) which is a modified technique of tension band wires (TBW) for Mayo type II A and III A olecranon fractures. In this technique the K-wires of the TBW are replaced by a cerclage wire while keeping the figure of eight wiring. We reviewed retrospectively our WTBW cases done between 2000 and 2015 where we replaced the K-wires by a cerclage wire. In this technique no hardware migration is possible. Patients were evaluated clinically, radiographicaly and a DASH score was measured. Seventeen patients were reviewed with a mean age of 58.5 years. The mean follow-up period was 58.5 months. The mean DASH score was 12 with 7 patients having a DASH score of zero. Joint mobility was near normal compared to the other side with loss of a mean of 4º in elbow extension and a mean of 3º in elbow flexion. In comparison with other series, in addition to good results, hardware removal for medical reasons was the lowest in our technique. It was needed in three patients for pain on elbow contact and in one with ulnar nerve irritation. This represents a rate of 23.5%. Undesirable events related to the use of K-wires in standard tension band wiring, such as wire migration, wire protrusion through the skin and wire impingement, are absent in the wireless tension band wiring. The high rate of patient satisfaction, good clinical results as well as low rate of needed hardware removal make this technique preferable for fixing Mayo Type II A olecranon fractures.