WorldWideScience

Sample records for fast track development

  1. Accelerated Leadership Development: Fast Tracking School Leaders

    Science.gov (United States)

    Earley, Peter; Jones, Jeff

    2010-01-01

    "Accelerated Leadership Development" captures and communicates the lessons learned from successful fast-track leadership programmes in the private and public sector, and provides a model which schools can follow and customize as they plan their own leadership development strategies. As large numbers of headteachers and other senior staff…

  2. Controlling type I error rate for fast track drug development programmes.

    Science.gov (United States)

    Shih, Weichung J; Ouyang, Peter; Quan, Hui; Lin, Yong; Michiels, Bart; Bijnens, Luc

    2003-03-15

    The U.S. Food and Drug Administration (FDA) Modernization Act of 1997 has a Section (No. 112) entitled 'Expediting Study and Approval of Fast Track Drugs' (the Act). In 1998, the FDA issued a 'Guidance for Industry: the Fast Track Drug Development Programs' (the FTDD programmes) to meet the requirement of the Act. The purpose of FTDD programmes is to 'facilitate the development and expedite the review of new drugs that are intended to treat serious or life-threatening conditions and that demonstrate the potential to address unmet medical needs'. Since then many health products have reached patients who suffered from AIDS, cancer, osteoporosis, and many other diseases, sooner by utilizing the Fast Track Act and the FTDD programmes. In the meantime several scientific issues have also surfaced when following the FTDD programmes. In this paper we will discuss the concept of two kinds of type I errors, namely, the 'conditional approval' and the 'final approval' type I errors, and propose statistical methods for controlling them in a new drug submission process. Copyright 2003 John Wiley & Sons, Ltd.

  3. Fast track-hoftealloplastik

    DEFF Research Database (Denmark)

    Hansen, Torben Bæk; Gromov, Kirill; Kristensen, Billy B

    2017-01-01

    Fast-track surgery implies a coordinated perioperative approach aimed at reducing surgical stress and facilitating post-operative recovery. The fast-track programme has reduced post-operative length of stay and has led to shorter convalescence with more rapid functional recovery and decreased...... morbidity and mortality in total hip arthroplasty. It should now be a standard total hip arthroplasty patient pathway, but fine tuning of the multiple factors in the fast-track pathway is still needed in patients with special needs or high comorbidity burden....

  4. Fast-track totalknæalloplastik

    DEFF Research Database (Denmark)

    Gromov, Kirill; Kristensen, Billy B; Jørgensen, Christoffer Calov

    2017-01-01

    patients are eligible for fast-track TKA, and hence the fast-track concept should be standard at all joint replacement facilities. Future challenges of fast-track TKA include safe introduction of outpatient protocols, acute and chronic pain after surgery and optimal utilization of post......Fast-track total knee arthroplasty (TKA) is a well-established concept including optimized logistics and evidence-based treatment, focusing on minimizing surgical stress and improved post-operative recovery, thus leading to lower mortality and morbidity as well as high patient satisfaction. All...

  5. Cardiac surgery fast-track treatment in a postanesthetic care unit: six-month results of the Leipzig fast-track concept.

    Science.gov (United States)

    Ender, Joerg; Borger, Michael Andrew; Scholz, Markus; Funkat, Anne-Kathrin; Anwar, Nadeem; Sommer, Marcus; Mohr, Friedrich Wilhelm; Fassl, Jens

    2008-07-01

    The authors compared the safety and efficacy of a newly developed fast-track concept at their center, including implementation of a direct admission postanesthetic care unit, to standard perioperative management. All fast-track patients treated within the first 6 months of implementation of our direct admission postanesthetic care unit were matched via propensity scores and compared with a historical control group of patients who underwent cardiac surgery prior to fast-track implementation. A total of 421 fast-track patients were matched successfully to 421 control patients. The two groups of patients had a similar age (64 +/- 13 vs. 64 +/- 12 yr for fast-track vs. control, P = 0.45) and European System for Cardiac Operative Risk Evaluation-predicted risk of mortality (4.8 +/- 6.1% vs. 4.6 +/- 5.1%, P = 0.97). Fast-track patients had significantly shorter times to extubation (75 min [45-110] vs. 900 min [600-1140]), as well as shorter lengths of stay in the postanesthetic or intensive care unit (4 h [3.0-5] vs. 20 h [16-25]), intermediate care unit (21 h [17-39] vs. 26 h [19-49]), and hospital (10 days [8-12] vs. 11 days [9-14]) (expressed as median and interquartile range, all P operations.

  6. Percentage of Fast-Track Receipts

    Data.gov (United States)

    Social Security Administration — The dataset provides the percentage of fast-track receipts by state during the reporting fiscal year. Fast-tracked cases consist of those cases identified as Quick...

  7. Evidence Basis for Regional Anesthesia in Multidisciplinary Fast-Track Surgical Care Pathways

    DEFF Research Database (Denmark)

    Carli, Francesco; Kehlet, Henrik; Baldini, Gabriele

    2011-01-01

    Fast-track programs have been developed with the aim to reduce perioperative surgical stress and facilitate patient's recovery after surgery. Potentially, regional anesthesia and analgesia techniques may offer physiological advantages to support fast-track methodologies in different type of surge......Fast-track programs have been developed with the aim to reduce perioperative surgical stress and facilitate patient's recovery after surgery. Potentially, regional anesthesia and analgesia techniques may offer physiological advantages to support fast-track methodologies in different type...... of surgeries. The aim of this article was to identify and discuss potential advantages offerred by regional anesthesia and analgesia techniques to fast-track programs. In the first section, the impact of regional anesthesia on the main elements of fast-track surgery is addressed. In the second section......, procedure-specific fast-track programs for colorectal, hernia, esophageal, cardiac, vascular, and orthopedic surgeries are presented. For each, regional anesthesia and analgesia techniques more frequently used are discussed. Furthermore, clinical studies, which included regional techniques as elements...

  8. Fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik

    2012-01-01

    Fast-track hip and knee arthroplasty aims at giving the patients the best available treatment at all times, being a dynamic entity. Fast-track combines evidence-based, clinical features with organizational optimization including a revision of traditions resulting in a streamlined pathway from...... on clinical and organizational aspects of fast-track hip and knee arthroplasty (I–IX). A detailed description of the fast-track set-up and its components is provided. Major results include identification of patient characteristics to predict length of stay and satisfaction with different aspects...... of the hospital stay (I); how to optimize analgesia by using a compression bandage in total knee arthroplasty (II); the clinical and organizational set-up facilitating or acting as barriers for early discharge (III); safety aspects following fast-track in the form of few readmissions in general (IV) and few...

  9. Fast-track revision knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B

    2011-01-01

    Abstract Background and purpose Fast-track surgery has reduced the length of hospital stay (LOS), morbidity, and convalescence in primary hip and knee arthroplasty (TKA). We assessed whether patients undergoing revision TKA for non-septic indications might also benefit from fast-track surgery....... Methods 29 patients were operated with 30 revision arthroplasties. Median age was 67 (34-84) years. All patients followed a standardized fast-track set-up designed for primary TKA. We determined the outcome regarding LOS, morbidity, mortality, and satisfaction. Results Median LOS was 2 (1-4) days...

  10. Fast-track knee arthroplasty – status and future challenges

    DEFF Research Database (Denmark)

    Kehlet, Henrik; Thienpont, Emmanuel

    2013-01-01

    Fast-track programs have been developed for different surgical procedures leading to higher patient satisfaction and lower morbidity. This concept has been extended to knee arthroplasty in recent years. The purpose of this narrative review was to discuss the different aspects of fast-track knee...... arthroplasty....

  11. Fast-track revision knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B

    2011-01-01

    Abstract Background and purpose Fast-track surgery has reduced the length of hospital stay (LOS), morbidity, and convalescence in primary hip and knee arthroplasty (TKA). We assessed whether patients undergoing revision TKA for non-septic indications might also benefit from fast-track surgery...

  12. FAST-TRACK HIP AND KNEE ARTHROPLASTY (LITERATURE REVIEW

    Directory of Open Access Journals (Sweden)

    A. M. Ageenko

    2017-01-01

    Full Text Available In the present paper the authors discuss the history of fast-track formation, its development and current status. Fast-track advantages in comparison to other rehabilitation options are analyzed. The focus is placed on methods of accelerated rehabilitation after total hip and knee arthroplasty in the leading European and American clinics. Fast-track protocols of surgical centers of Denmark and Hospital for special surgery in the US are described, factors that determine time of hospital stay after total hip and knee arthroplasty are considered, predictors of hospital stay and patients satisfaction after the surgery are examined. The paper reflects the results of the comparison of frequency of thromboembolic and other complications as well as readmission rate after traditional rehabilitation and after fast-track. The paper considers fast-track in bilateral total knee replacement. The authors conclude that further research on acceleration of rehabilitation and reduction of hospital stay after total hip and knee arthroplasty needs to be focused on the optimization of pain relief, especially after discharge, blood preservation techniques, supplementation of fluids loss and strengthening of muscles. Literature analysis demonstrated that the implementation of the Protocol for accelerated recovery after joint arthroplasty in Russia is at an insufficient level. Data of foreign multicenter studies during recent years indicate a high efficacy and safety of this technique in different groups of patients.

  13. Fast-track surgery for breast cancer is possible

    DEFF Research Database (Denmark)

    Mertz, Birgitte G; Kroman, Niels; Williams, Helene

    2013-01-01

    INTRODUCTION: Breast cancer is common among Danish women with more than 4,100 new cases annually. In 2008 the concept of fast-track surgery was introduced at the Department of Breast Surgery at Rigshospitalet, Copenhagen. The aim of this study is to describe the new clinical pathway for breast...... to provide immediate advice and support. CONCLUSION: The results confirm that a short stay can be successfully carried out for breast cancer patients. Implementing the fast-track programme involved the introduction of a clear clinical pathway for the patients and more effective daily routines. Patients felt...... cancer patients after implementation of a fast-track surgery programme. MATERIAL AND METHODS: A clinical pathway of all involved disciplines was developed including anaesthetic, analgesics, nausea and vomiting, drain and wound management, discharge assessment and psychosocial support. RESULTS...

  14. Evidence Basis for Regional Anesthesia in Multidisciplinary Fast-Track Surgical Care Pathways

    DEFF Research Database (Denmark)

    Carli, Francesco; Kehlet, Henrik; Baldini, Gabriele

    2011-01-01

    Fast-track programs have been developed with the aim to reduce perioperative surgical stress and facilitate patient's recovery after surgery. Potentially, regional anesthesia and analgesia techniques may offer physiological advantages to support fast-track methodologies in different type...... of surgeries. The aim of this article was to identify and discuss potential advantages offerred by regional anesthesia and analgesia techniques to fast-track programs. In the first section, the impact of regional anesthesia on the main elements of fast-track surgery is addressed. In the second section......, procedure-specific fast-track programs for colorectal, hernia, esophageal, cardiac, vascular, and orthopedic surgeries are presented. For each, regional anesthesia and analgesia techniques more frequently used are discussed. Furthermore, clinical studies, which included regional techniques as elements...

  15. Fast-track surgery: Toward comprehensive peri-operative care.

    Science.gov (United States)

    Nanavati, Aditya J; Prabhakar, S

    2014-01-01

    Fast-track surgery is a multimodal approach to patient care using a combination of several evidence-based peri-operative interventions to expedite recovery after surgery. It is an extension of the critical pathway that integrates modalities in surgery, anesthesia, and nutrition, enforces early mobilization and feeding, and emphasizes reduction of the surgical stress response. It entails a great partnership between a surgeon and an anesthesiologist with several other specialists to form a multi-disciplinary team, which may then engage in patient care. The practice of fast-track surgery has yielded excellent results and there has been a significant reduction in hospital stay without a rise in complications or re-admissions. The effective implementation begins with the formulation of a protocol, carrying out each intervention and gathering outcome data. The care of a patient is divided into three phases: Before, during, and after surgery. Each stage needs active participation of few or all the members of the multi-disciplinary team. Other than surgical technique, anesthetic drugs, and techniques form the cornerstone in the ability of the surgeon to carry out a fast-track surgery safely. It is also the role of this team to keep abreast with the latest development in fast-track methodology and make appropriate changes to policy. In the Indian healthcare system, there is a huge benefit that may be achieved by the successful implementation of a fast-track surgery program at an institutional level. The lack of awareness regarding this concept, fear and apprehension regarding its implementation are the main barriers that need to be overcome.

  16. "Fast Track" and "Traditional Path" Coaches: Affordances, Agency and Social Capital

    Science.gov (United States)

    Rynne, Steven

    2014-01-01

    A recent development in large-scale coach accreditation (certification) structures has been the "fast tracking" of former elite athletes. Former elite athletes are often exempted from entry-level qualifications and are generally granted access to fast track courses that are shortened versions of the accreditation courses undertaken by…

  17. ATLAS FTK: Fast Track Trigger

    CERN Document Server

    Volpi, Guido; The ATLAS collaboration

    2015-01-01

    An overview of the ATLAS Fast Tracker processor is presented, reporting the design of the system, its expected performance, and the integration status. The next LHC runs, with a significant increase in instantaneous luminosity, will provide a big challenge to the trigger and data acquisition systems of all the experiments. An intensive use of the tracking information at the trigger level will be important to keep high efficiency in interesting events, despite the increase in multiple p-p collisions per bunch crossing (pile-up). In order to increase the use of tracks within the High Level Trigger (HLT), the ATLAS experiment planned the installation of an hardware processor dedicated to tracking: the Fast TracKer (FTK) processor. The FTK is designed to perform full scan track reconstruction at every Level-1 accept. To achieve this goal, the FTK uses a fully parallel architecture, with algorithms designed to exploit the computing power of custom VLSI chips, the Associative Memory, as well as modern FPGAs. The FT...

  18. Fast emulation of track reconstruction in the CMS simulation

    CERN Document Server

    Komm, Matthias

    2017-01-01

    Simulated samples of various physics processes are a key ingredient within analyses to unlock the physics behind LHC collision data. Samples with more and more statistics are required to keep up with the increasing amounts of recorded data. During sample generation, significant computing time is spent on the reconstruction of charged particle tracks from energy deposits which additionally scales with the pileup conditions. In CMS, the FastSimulation package is developed for providing a fast alternative to the standard simulation and reconstruction workflow. It employs various techniques to emulate track reconstruction effects in particle collision events. Several analysis groups in CMS are utilizing the package, in particular those requiring many samples to scan the parameter space of physics models (e.g. SUSY) or for the purpose of estimating systematic uncertainties. The strategies for and recent developments in this emulation are presented, including a novel, flexible implementation of tracking emulation w...

  19. Fast-track video-assisted thoracoscopic surgery

    DEFF Research Database (Denmark)

    Holbek, Bo Laksafoss; Petersen, René Horsleben; Kehlet, Henrik

    2016-01-01

    Objectives To provide a short overview of fast-track video-assisted thoracoscopic surgery (VATS) and to identify areas requiring further research. Design A literature search was made using key words including: fast-track, enhanced recovery, video-assisted thoracoscopic surgery, robot......-assisted thoracoscopic surgery (RATS), robotic, thoracotomy, single-incision, uniportal, natural orifice transluminal endoscopic surgery (NOTES), chest tube, air-leak, digital drainage, pain management, analgesia, perioperative management, anaesthesia and non-intubated. References from articles were screened for further...

  20. [Fast-track treatment--second revolution of colorectal surgery].

    Science.gov (United States)

    Kellokumpu, Ilmo

    2012-01-01

    The fast-track treatment model can be regarded as the second revolution of colorectal surgery after the introduction of laparoscopic surgery. In the gastro-surgical unit of the Central Hospital of Central Finland, results equivalent to international studies in colorectal surgery have been achieved by using fast-track model. In a study setting, this treatment model has resulted in significant decrease of total treatment costs and speeded up discharge of the patients from the hospital. The fast-track treatment model requires both a motivated, trained medical team and a motivated patient.

  1. Standardising fast-track surgical nursing care in Denmark

    DEFF Research Database (Denmark)

    Hjort Jakobsen, Dorthe; Rud, Kirsten; Kehlet, Henrik

    2014-01-01

    guidelines based on the principles of fast-track surgery-i.e. patient information, surgical stress reduction, effective analgesia, early mobilisation and rapid return to normal eating. Fast-track surgery was introduced systematically in Denmark by the establishment of the Unit of Perioperative Nursing (UPN...

  2. Development of Ultra-Fast Silicon Detectors for 4D tracking

    Science.gov (United States)

    Staiano, A.; Arcidiacono, R.; Boscardin, M.; Dalla Betta, G. F.; Cartiglia, N.; Cenna, F.; Ferrero, M.; Ficorella, F.; Mandurrino, M.; Obertino, M.; Pancheri, L.; Paternoster, G.; Sola, V.

    2017-12-01

    In this contribution we review the progress towards the development of a novel type of silicon detectors suited for tracking with a picosecond timing resolution, the so called Ultra-Fast Silicon Detectors. The goal is to create a new family of particle detectors merging excellent position and timing resolution with GHz counting capabilities, very low material budget, radiation resistance, fine granularity, low power, insensitivity to magnetic field, and affordability. We aim to achieve concurrent precisions of ~ 10 ps and ~ 10 μm with a 50 μm thick sensor. Ultra-Fast Silicon Detectors are based on the concept of Low-Gain Avalanche Detectors, which are silicon detectors with an internal multiplication mechanism so that they generate a signal which is factor ~10 larger than standard silicon detectors. The basic design of UFSD consists of a thin silicon sensor with moderate internal gain and pixelated electrodes coupled to full custom VLSI chip. An overview of test beam data on time resolution and the impact on this measurement of radiation doses at the level of those expected at HL-LHC is presented. First I-V and C-V measurements on a new FBK sensor production of UFSD, 50 μm thick, with B and Ga, activated at two diffusion temperatures, with and without C co-implantation (in Low and High concentrations), and with different effective doping concentrations in the Gain layer, are shown. Perspectives on current use of UFSD in HEP experiments (UFSD detectors have been installed in the CMS-TOTEM Precision Protons Spectrometer for the forward physics tracking, and are currently taking data) and proposed applications for a MIP timing layer in the HL-LHC upgrade are briefly discussed.

  3. Delirium after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Krenk, Lene; Rasmussen, L S; Hansen, T B

    2012-01-01

    hospital stay and medical morbidity. No data on PD are available in fast-track surgery. The aim of this study was to evaluate the incidence of PD after fast-track hip (THA) and knee arthroplasty (TKA) with anticipated length of stay (LOS) of In a prospective multicentre study to evaluate postoperative...

  4. Fast-Track Teacher Recruitment.

    Science.gov (United States)

    Grant, Franklin Dean

    2001-01-01

    Schools need a Renaissance human-resources director to implement strategic staffing and fast-track teacher-recruitment plans. The HR director must attend to customer satisfaction, candidate supply, web-based recruitment possibilities, stabilization of newly hired staff, retention of veteran staff, utilization of retired employees, and latest…

  5. Fast track pathway for perforated appendicitis.

    Science.gov (United States)

    Frazee, Richard; Abernathy, Stephen; Davis, Matthew; Isbell, Travis; Regner, Justin; Smith, Randall

    2017-04-01

    Perforated appendicitis is associated with an increased morbidity and length of stay. "Fast track" protocols have demonstrated success in shortening hospitalization without increasing morbidity for a variety of surgical processes. This study evaluates a fast track pathway for perforated appendicitis. In 2013, a treatment pathway for perforated appendicitis was adopted by the Acute Care Surgery Service for patients having surgical management of perforated appendicitis. Interval appendectomy was excluded. Patients were treated initially with intravenous antibiotics and transitioned to oral antibiotics and dismissed when medically stable and tolerating oral intake. A retrospective review of patients managed on the fast track pathway was undertaken to analyze length of stay, morbidity, and readmissions. Thirty-four males and twenty-one females with an average age of 46.8 years underwent laparoscopic appendectomy for perforated appendicitis between January 2013 and December 2014. Pre-existing comorbidities included hypertension 42%, diabetes mellitus 11%, COPD 5% and heart disease 2%. No patient had conversion to open appendectomy. Average length of stay was 2.67 days and ranged from 1 to 12 days (median 2 days). Postoperative morbidity was 20% and included abscess (6 patients), prolonged ileus (3 patients), pneumonia (1 patient), and congestive heart failure (1 patient). Five patients were readmitted for abscess (3 patients), congestive heart failure (1 patient), and pneumonia (1 patient). A fast track pathway for perforated appendicitis produced shorter length of stay and acceptable postoperative morbidity and readmission. This offers the potential for significant cost savings over current national practice patterns. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Fast-Track Management of Patients Undergoing Proximal Pancreatic Resection

    Science.gov (United States)

    French, JJ; Mansfield, SD; Jaques, K; Jaques, BC; Manas, DM; Charnley, RM

    2009-01-01

    INTRODUCTION To avoid the risk of complications of biliary drainage, a feasibility study was carried out to determine whether it might be possible to fast-track surgical treatment, with resection before biliary drainage, in jaundiced patients with proximal pancreatic/peri-ampullary malignancy. PATIENTS AND METHODS Over an 18-month period, based on their presenting bilirubin levels and other logistical factors, all jaundiced patients who might be suitable for fast-track management were identified. Data on complications and hospital stay were compared with those patients in whom a conventional pathway (with biliary drainage) was used during the same time period. Data were also compared with a group of patients from the preceding 6 months. RESULTS Nine patients were fast-tracked and 49 patients treated in the conventional pathway. Fast-track patients mean (SD) serum bilirubin level was 265 μmol/l (81.6) at the time of the operation compared to 43 μmol/l (51.3; P ≥ 0.0001) in conventional patients. Mean (SD) of time from referral to operation, 14 days (9) versus 59 days (36.9), was significantly shorter in fast-track patients than conventional patients (P ≤ 0.0001). Length of hospital stay mean (SD) at 17 (6) days versus 22 days (19.6; P = 0.2114), surgical complications and mortality in fast-track patients were similar to conventional patients. Prior to surgery, the 49 conventional patients underwent a total of 73 biliary drainage procedures resulting in seven major complications. Comparison with the group of patients from the previous 6 months indicated that the conventional group were not disadvantaged. CONCLUSIONS Fast-track management by resection without biliary drainage of selected patients with distal biliary strictures is safe and has the potential to reduce the waiting time to surgery, overall numbers of biliary drainage procedures and the complications thereof. PMID:19220943

  7. Fast tracking in paediatric cardiac anaesthesia : an update.

    Directory of Open Access Journals (Sweden)

    Lake Carol

    2002-01-01

    Full Text Available A care plan in which cardiac surgical patients progress quickly through the perioperative course to hospital discharge is often referred to as a Fast Track. Such care plans have been used extensively in adult cardiac patients but are also applicable to paediatric patients. Although no randomised controlled trials are available to document a reduction in hospital costs and avoidance of iatrogenic complications with paediatric fast tracks, many healthcare administrators encourage their use. Fast Track clinical guidelines usually include same day surgery, use of short- acting anaesthetic drugs, early extubation, effective pain management, and reduced intensive care unit stays. These protocols are certainly appropriate for simple procedures such as repair of atrial or ventricular septal defects or ligation of a patent ductus arteriosus. However, many paediatric cardiac anaesthesiologists consider that all paediatric patients without significant pulmonary or residual cardiac pathology can be managed using expedited postoperative protocols. Essential components in a "fast track" protocol include use of minimally invasive surgical techniques, modified ultrafiltration during cardiopulmonary bypass, transoesophageal echocardiography to evaluate the cardiac repair, and postoperative pain control. Using such techniques, 80-90% of paediatric patients can be extubated in the operating room or within 2-4 hours postoperatively. Despite the opinions of recognised experts, an appropriately sized and powered multicentre, controlled, randomised, prospective study is still needed to conclusively document the efficiency and effectiveness of the Fast Track in paediatric cardiac patients.

  8. Sufentanil Vs Fentanyl for Fast-Track Cardiac Anaesthesia

    Directory of Open Access Journals (Sweden)

    C M Deshpande

    2009-01-01

    Full Text Available A perioperative anaesthetic management that aims to facilitate tracheal extubation of patients within 1-6 hrs after cardiac surgery is called "fast-track′. Main advantage of ′fast-track" method is better usage of medical resources and lowering hospital costs without increasing morbidity and mortality of the patients. Standard fast-track protocols contain short acting anaesthetic agents, smaller incisions and decreased pump times without hypothermia. In this study we compared two short acting opioid drugs, fentanyl versus Sufentanil when used as a part of the balanced anaesthesia technique for fast track in cardiac surgery patients& evaluated the time taken for extubation, haemodynamic stability, analgesia requirements& incidence of awareness. The results from the study show thatboth agents provide good haemodynamic stability and postoperative analgesia. Although Sufentanil provides earlier extuba-tion, both agents reduce the ICU stay equally. In conclusion both agents can be used effectively for fasttrack cardiac anaesthesia.

  9. FTK: a Fast Track Trigger for ATLAS

    International Nuclear Information System (INIS)

    Anderson, J; Auerbach, B; Blair, R; Andreani, A; Andreazza, A; Citterio, M; Annovi, A; Beretta, M; Castegnaro, A; Atkinson, M; Cavaliere, V; Chang, P; Bevacqua, V; Crescioli, F; Blazey, G; Bogdan, M; Boveia, A; Canelli, F; Cheng, Y; Cervigni, F

    2012-01-01

    We describe the design and expected performance of a the Fast Tracker Trigger (FTK) system for the ATLAS detector at the Large Hadron Collider. The FTK is a highly parallel hardware system designed to operate at the Level 1 trigger output rate. It is designed to provide global tracks reconstructed in the inner detector with resolution comparable to the full offline reconstruction as input of the Level 2 trigger processing. The hardware system is based on associative memories for pattern recognition and fast FPGAs for track reconstruction. The FTK is expected to dramatically improve the performance of track based isolation and b-tagging with little to no dependencies of pile-up interactions.

  10. Delirium in the fast-track surgery setting

    DEFF Research Database (Denmark)

    Krenk, Lene; Rasmussen, Lars S; Kehlet, Henrik

    2012-01-01

    Postoperative delirium (PD) and postoperative cognitive dysfunction (POCD) are two separate syndromes of cognitive decline after major surgery, especially in the elderly. Pathogenesis is multifactorial with some common risk factors, and to reduce the risk, a multimodal approach is necessary. The ....... In conclusion, the fast-track methodology may reduce the incidence of postoperative cognitive decline after surgery........ The fast-track methodology is becoming a well-established perioperative care regime with possible preventive effects for postoperative cognitive decline, including reduced pain and use of opioids, and early mobilisation with early discharge (≤3 days) to preoperative environment after total hip....../knee arthroplasty (THA/TKA). The fast-track set-up seems to be associated with a lower frequency of PD and early POCD after THA/TKA. Thus, in a series of 225 patients ≥60 years, no cases of PD were seen and the incidence of POCD was reduced by more than 50% at 1 week postoperatively compared to previous studies...

  11. Orchestrating care through the fast-track perspective: A qualitative content analysis of the provision of individualised nursing care in orthopaedic fast-track programmes.

    Science.gov (United States)

    Berthelsen, Connie Bøttcher; Frederiksen, Kirsten

    2017-02-01

    The lack of individualised care in orthopaedic regimes is often explained by the extended use of patient pathways and clinical guidelines. The aim of this study was to illuminate orthopaedic nurses' perceptions and experiences of providing individual nursing care for older patients in standardised fast-track programmes after total hip or knee replacement. Ten semi-structured interviews were conducted with orthopaedic nurses in orthopaedic wards at three Danish hospitals between April and June of 2015. Data were analysed using manifest and latent content analysis according to Graneheim and Lundman. The main theme of the overall interpretation was Orchestrating care through the fast-track perspective, accompanied by three sub-themes: Identifying and legitimising relevant individual care in the fast-track programme, Struggling to fit all patients in the fast-track programme and Justifying individualised care-related actions in the fast-track programme. The study concluded that, even though the nurses struggled to comply with the programme, they still found themselves compromising their nursing care and ethics to follow the standardised regime. There is a need to establish more specific inclusion criteria to maintain the effective elements in the programme and to facilitate nurses' opportunities to offer individual care, thereby ensuring that fragile patients have access to other possibilities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Effect of an Emergency Department Fast Track on Press-Ganey Patient Satisfaction Scores

    Directory of Open Access Journals (Sweden)

    Hwang, Calvin E.

    2014-12-01

    Full Text Available Introduction: Mandated patient surveys have become an integral part of Medicare remuneration, putting hundreds of millions of dollars in funding at risk. The Centers for Medicare & Medicaid Services (CMS recently announced a patient experience survey for the emergency department (ED. Development of an ED Fast Track, where lower acuity patients are rapidly seen, has been shown to improve many of the metrics that CMS examines. This is the first study examining if ED Fast Track implementation affects Press-Ganey scores of patient satisfaction. Methods: We analyzed returned Press-Ganey questionnaires from all ESI 4 and 5 patients seen 11AM - 11PM, August-December 2011 (pre-fast track, and during the identical hours of fast track, August-December 2012. Raw ordinal scores were converted to continuous scores for paired student t-test analysis. We calculated an odds ratio with 100% satisfaction considered a positive response. Results: An academic ED with 52,000 annual visits had 140 pre-fast track and 85 fast track respondents. Implementation of a fast track significantly increased patient satisfaction with the following: wait times (68% satisfaction to 88%, OR 4.13, 95% CI [2.32-7.33], doctor courtesy (90% to 95%, OR 1.97, 95% CI [1.04-3.73], nurse courtesy (87% to 95%, OR 2.75, 95% CI [1.46-5.15], pain control (79% to 87%, OR 2.13, 95% CI [1.16-3.92], likelihood to recommend (81% to 90%, OR 2.62, 95% CI [1.42-4.83], staff caring (82% to 91%, OR 2.82, 95% CI [1.54-5.19], and staying informed about delays (66% to 83%, OR 3.00, 95% CI [1.65-5.44]. Conclusion: Implementation of an ED Fast Track more than doubled the odds of significant improvements in Press-Ganey patient satisfaction metrics and may play an important role in improving ED performance on CMS benchmarks. [West J Emerg Med. 2015;16(1:34–38.

  13. Short Hospital Stay after Laparoscopic Colorectal Surgery without Fast Track

    DEFF Research Database (Denmark)

    Burgdorf, Stefan K; Rosenberg, Jacob

    2012-01-01

    Purpose. Short hospital stay and equal or reduced complication rates have been demonstrated after fast track open colonic surgery. However, fast track principles of perioperative care can be difficult to implement and often require increased nursing staff because of more concentrated nursing tasks...... care, that is, without implementing fast track principles, on length of stay after colorectal resection for cancer. Methods. Records of all patients operated for colorectal cancer from November 2004 to December 2008 in our department were reviewed. No specific patients were selected for laparoscopic...... in our department resulted in shorter hospital stay without using fast track principles for peri- and postoperative care in patients not receiving a stoma during the operation. Consequently, we aimed to reduce hospitalisation without increasing cost in nursing staff per hospital bed. Length of stay...

  14. Fast-track Orthognathic Surgery: An Evidence-based Review

    Science.gov (United States)

    Otero, Joel Joshi; Detriche, Olivier; Mommaerts, Maurice Yves

    2017-01-01

    The aim of this study was to establish a fast-track protocol for bimaxillary orthognathic surgery (OGS). Fast-track surgery (FTS) is a multidisciplinary approach where the pre-, intra-, and postoperative management is focusing maximally on a quick patient recovery and early discharge. To enable this, the patients’ presurgical stress and postsurgical discomfort should be maximally reduced. Both referral patterns and expenses within the health-care system are positively influenced by FTS. University hospital-literature review through Medline, Embase, and the Cochrane Library (January 2000–July 2016) using the following words – “fast track, enhanced recovery, multimodal, and perioperative care” – to define a protocol evidence based for OGS, as well as evidenced-based medicine search of every term added to the protocol during the same period. The process has resulted in an OGS protocol that may improve the outcome of the patient through several nonoperative and operative measures such as preoperative patient education and intra/postoperative measures that should improve overall patient satisfaction, decrease morbidity such as postoperative nausea, headache, dizziness, pain, and intubation discomfort, and shorten hospital stay. A literature review allowed us to fine-tune a fast-track protocol for uncomplicated OGS that can be prospectively studied against currently applied ones. PMID:29264281

  15. Safety of fast track surgery in pancreaticoduodenectomy: a Meta-analysis

    Directory of Open Access Journals (Sweden)

    LI Weinan

    2017-01-01

    Full Text Available ObjectiveTo investigate the safety and clinical effect of fast track surgery in pancreaticoduodenectomy, one of the most complex surgeries in general surgery. MethodsThe Chinese and foreign databases were searched for articles on the application of fast tract surgery in pancreaticoduodenectomy published from January 1994 to April 2016. Two researchers evaluated the quality of the articles which met the inclusion criteria and extracted related data. Stata 12.0 software was used to analyze the overall incidence rate of complications and the incidence rates of pancreatic leakage and gastrointestinal emptying disorder, and the Begg rank correlation test and Egger linear regression method were used to investigate publication bias. ResultsThe fast track surgery group had a significantly lower overall incidence rate of complications than the conventional group (RR=0.748, 95%CI: 0.680-0.824, P<0.001. There was no significant difference in the incidence rate of pancreatic leakage between the two groups (RR=0.894, 95%CI:0.734-1.089, P=0.266. The fast track surgery group had a significantly lower incidence rate of gastrointestinal emptying disorder than the conventional group (RR=0.520, 95%CI:0.400-0.670, P<0.001. ConclusionFast track surgery is safe and effective in pancreaticoduodenectomy, but the application of some measures in fast track surgery still needs more medical evidence.

  16. Bilateral simultaneous total hip arthroplasty in a fast track setting

    DEFF Research Database (Denmark)

    Otte, Kristian S; Husted, Henrik; Ørsnes, Thue

    2011-01-01

    and low complication rates when performed in a fast-track setting. We believed it would be useful to assess hip arthroplasty in this context, and we report 50 consecutive fast-track simultaneous bilateral hip arthroplasty procedures. The median length of stay was 4 days. Mortality within 90 days was 4......% and 8% required a further operative procedure. The overall complication rate was 22%. 55% of the complications were considered to be caused by failures in surgical technique and 45% by other factors. Bilateral simultaneous hip arthroplasty may have a high complication rate in a fast-track setting...

  17. Care principles at four fast-track arthroplasty departments in Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Solgaard, Søren; Hansen, Torben B

    2010-01-01

    The goal of this study was to describe the logistic and clinical set-up at four Danish arthroplasty departments offering fast-track surgery.......The goal of this study was to describe the logistic and clinical set-up at four Danish arthroplasty departments offering fast-track surgery....

  18. ATLAS FTK Fast Track Trigger

    CERN Document Server

    Iizawa, T; The ATLAS collaboration

    2014-01-01

    The Fast TracKer (FTK) will perform global track reconstruction after each Level-1 trigger accept signal to enable the software-based higher level trigger to have early access to tracking information. FTK is a dedicated processor based on a mixture of advanced technologies. Modern, powerful Field Programmable Gate Arrays (FPGAs) form an important part of the system architecture, and the large level of computing power required for pattern recognition is provided by incorporating standard-cell ASICs named Associative Memory (AM). Motivation and the architecture of the FTK system will be presented, and the status of hardware and simulation will be following.

  19. Nursing care in fast-track surgery strategy

    Directory of Open Access Journals (Sweden)

    Dorota Kozieł

    2015-10-01

    Full Text Available In recent years, many study results have been published confirming an improvement in the outcomes of treatment related with management of patients within the fast-track surgery programme. Early postoperative rehabilitation is possible provided there is engagement of a multi-disciplinary team, including well-educated nurses. Today, a diversion can be observed from traditional nursing on behalf of a coordinated, holistic approach, while more attention is paid to the, thus far marginalised, psychosocial aspects of care. The objective of the study is to discuss the basic assumptions of fast track surgery with respect to nursing care, with particular emphasis placed on the educational function. Modern nursing within the short-track surgery programme should focus on the provision of patients with care consisting of preliminary information concerning the perioperative period, social and psychological support, counselling in the area of home convalescence, and procedures in the case of complications.

  20. An innovative strategy to increase a professional workforce: the fast track initiative for health visitors in England.

    Science.gov (United States)

    Sayer, Lynn; Barriball, K Louise; Bliss, Julie; Bakhshi, Savita; While, Alison E

    2016-04-01

    Fast tracking is one strategy that organizations use to ameliorate workforce shortfalls by attracting new recruits, and accelerating their skills development and experience. In response to the Government's target of rapidly expanding the number of health visitors in England's National Health Service, the fast track initiative was launched to recruit newly qualified (fast track) as well as experienced (standard entry) nurses and midwives onto health visiting programmes. This paper evaluates the fast track initiative, from the perspective of fast track and standard entry students, practice teachers and health visitor managers. A mixed methods design was used comprising a questionnaire survey (n = 71 students), semi-structured interviews (n = 37 students), telephone interviews (n = 13 managers) and six focus groups (n = 24 practice teachers). Data were collected between April 2012 and July 2013. Descriptive statistics, t-tests and the Pearson Chi-square test were used to analyse the quantitative data. The qualitative data were analysed thematically. Motivations for health visiting as a career choice were similar for fast track and standard entry students, with career progression and interest in health promotion being key motivators. There was consensus that personal qualities and characteristics were more important than experience or qualifications. However, fast track students were significantly less confident about their public health competencies in leadership and management (p communication (p  0.5). Fast tracking offers a useful recruitment strategy in order to expand the health visitor workforce, but longitudinal research is needed to confirm benefits such as retention and career trajectories. © The Author(s) 2015.

  1. Which fast track elements predict early recovery after colon cancer surgery?

    NARCIS (Netherlands)

    Vlug, M. S.; Bartels, S. A. L.; Wind, J.; Ubbink, D. T.; Hollmann, M. W.; Bemelman, W. A.; Sprangers, Mirjam; Preckel, Benedikt; Bossuyt, Patrick; Gouma, Dirk; van Berge Henegouwen, Mark; Fuhring, Jan; Lenthe, Ineke Picard-van; Bakker, Chris; King-Kalimanis, Bellinda; Hofland, Jan; Dejong, Cornelis; van Dam, Ronald; Cuesta, Miguel; van der Peet, Donald; van Zalingen, Edith; Noordhuis, Astrid; de Jong, Dick; Engel, Alexander; Goei, T. Hauwy; de Stoppelaar, Erica; van den Dongen, Marjon; van Wagensveld, Bart; van Tets, Willem; van den Elsen, Maarten; Swart, Annemiek; Gerhards, Michael; de Wit, Laurens; Siepel, Muriel; Molly, Glaresa; Gasthuis, Onze Lieve Vrouwe; van Geloven, Anna; Juttmann, Jan; Clevers, Wilfred; Bieleman, Andrea; van der Zaag, Edwin; Coenen, Ludo; Bonekamp, Elly; Cense, Huib; van Abeelen, Jacobus; van Iterson-de Jong, Diana; Krombeen, Margriet

    2012-01-01

    Aim It is questioned whether all separate fast track elements are essential for enhanced postoperative recovery. We aimed to determine which baseline characteristics and which fast track elements are independent predictors of faster postoperative recovery in patients undergoing resection for colon

  2. An artificial retina for fast track finding

    International Nuclear Information System (INIS)

    Ristori, Luciano

    2000-01-01

    A new approach is proposed for fast track finding in position-sensitive detectors. The basic working principle is modeled on what is widely believed to be the low-level mechanism used by the eye to recognize straight edges. A number of receptors are tuned such that each one responds to a different range of track orientations, each track actually fires several receptors and an estimate of the orientation is obtained through interpolation. The feasibility of a practical device based on this principle and its possible implementation using currently available digital logic is discussed

  3. Evaluation of a fast-track programme for patients undergoing liver resection

    DEFF Research Database (Denmark)

    Schultz, Nicolai A.; Larsen, Peter Nørgaard; Klarskov, Birthe Michaelsen

    2013-01-01

    BACKGROUND: Recent developments in perioperative pathophysiology and care have documented evidence-based, multimodal rehabilitation (fast-track) to hasten recovery and to decrease morbidity and hospital stay for several major surgical procedures. The aim of this study was to investigate the effect...

  4. PREDICTING A FAST-TRACK MARITIME CAREER: CHARACTERISTICS OF SUCCESSFUL OFFICERS DURING TEENAGE YEARS

    Directory of Open Access Journals (Sweden)

    Manuel Joaquín Fernández González

    2017-12-01

    Full Text Available Fast-track maritime career is a topical question worldwide due to the shortage of seafarers in maritime industry. Assuming that the fast-track career officers’ relevant common characteristics in adolescence could predict future maritime career speed, the research questions of this research are: What were the common characteristics of fast-track career officers when they were 16-18? Were there any statistically significant differences between the fast-track career groups and the officers with a slower career at that age? A questionnaire survey involving 175 maritime officers was conducted in Latvia in January – October 2016, regarding officers’ family context, school achievement, involvement in sports, and personality traits when they were 16-18. Fast-track career officers perceived themselves as more conscientious, calm and more leadership oriented than the whole group in adolescence. Statistically significant differences among career-speed groups were found regarding family socioeconomic status, family atmosphere and family career support at that age. Based on those communalities among maritime officers with a fast-track carrier when they were 16-18, maritime education and training institutions could better find and give appropriate career guidance to prospective maritime officers. Even if maritime career speed is a very individualized phenomenon, family characteristics could be studied further as a potential good predictor of fast-track maritime career.

  5. A fast fiducial marker tracking model for fully automatic alignment in electron tomography

    KAUST Repository

    Han, Renmin; Zhang, Fa; Gao, Xin

    2017-01-01

    Automatic alignment, especially fiducial marker-based alignment, has become increasingly important due to the high demand of subtomogram averaging and the rapid development of large-field electron microscopy. Among the alignment steps, fiducial marker tracking is a crucial one that determines the quality of the final alignment. Yet, it is still a challenging problem to track the fiducial markers accurately and effectively in a fully automatic manner.In this paper, we propose a robust and efficient scheme for fiducial marker tracking. Firstly, we theoretically prove the upper bound of the transformation deviation of aligning the positions of fiducial markers on two micrographs by affine transformation. Secondly, we design an automatic algorithm based on the Gaussian mixture model to accelerate the procedure of fiducial marker tracking. Thirdly, we propose a divide-and-conquer strategy against lens distortions to ensure the reliability of our scheme. To our knowledge, this is the first attempt that theoretically relates the projection model with the tracking model. The real-world experimental results further support our theoretical bound and demonstrate the effectiveness of our algorithm. This work facilitates the fully automatic tracking for datasets with a massive number of fiducial markers.The C/C ++ source code that implements the fast fiducial marker tracking is available at https://github.com/icthrm/gmm-marker-tracking. Markerauto 1.6 version or later (also integrated in the AuTom platform at http://ear.ict.ac.cn/) offers a complete implementation for fast alignment, in which fast fiducial marker tracking is available by the

  6. A fast fiducial marker tracking model for fully automatic alignment in electron tomography

    KAUST Repository

    Han, Renmin

    2017-10-20

    Automatic alignment, especially fiducial marker-based alignment, has become increasingly important due to the high demand of subtomogram averaging and the rapid development of large-field electron microscopy. Among the alignment steps, fiducial marker tracking is a crucial one that determines the quality of the final alignment. Yet, it is still a challenging problem to track the fiducial markers accurately and effectively in a fully automatic manner.In this paper, we propose a robust and efficient scheme for fiducial marker tracking. Firstly, we theoretically prove the upper bound of the transformation deviation of aligning the positions of fiducial markers on two micrographs by affine transformation. Secondly, we design an automatic algorithm based on the Gaussian mixture model to accelerate the procedure of fiducial marker tracking. Thirdly, we propose a divide-and-conquer strategy against lens distortions to ensure the reliability of our scheme. To our knowledge, this is the first attempt that theoretically relates the projection model with the tracking model. The real-world experimental results further support our theoretical bound and demonstrate the effectiveness of our algorithm. This work facilitates the fully automatic tracking for datasets with a massive number of fiducial markers.The C/C ++ source code that implements the fast fiducial marker tracking is available at https://github.com/icthrm/gmm-marker-tracking. Markerauto 1.6 version or later (also integrated in the AuTom platform at http://ear.ict.ac.cn/) offers a complete implementation for fast alignment, in which fast fiducial marker tracking is available by the

  7. Fast pattern recognition with the ATLAS L1Track trigger for HL-LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00530554; The ATLAS collaboration

    2017-01-01

    A fast hardware based track trigger is being developed in ATLAS for the High Luminosity upgrade of the Large Hadron Collider. The goal is to achieve trigger levels in the high pile-up conditions of the High Luminosity Large Hadron Collider that are similar or better than those achieved at low pile-up conditions by adding tracking information to the ATLAS hardware trigger. A method for fast pattern recognition using the Hough transform is investigated. In this method, detector hits are mapped onto a 2D parameter space with one parameter related to the transverse momentum and one to the initial track direction. The performance of the Hough transform is studied at different pile-up values. It is also compared, using full event simulation of events with average pile-up of 200, with a method based on matching detector hits to pattern banks of simulated tracks stored in a custom made Associative Memory ASICs. The pattern recognition is followed by a track fitting step which calculates the track parameters. The spee...

  8. An Improved Fast Compressive Tracking Algorithm Based on Online Random Forest Classifier

    Directory of Open Access Journals (Sweden)

    Xiong Jintao

    2016-01-01

    Full Text Available The fast compressive tracking (FCT algorithm is a simple and efficient algorithm, which is proposed in recent years. But, it is difficult to deal with the factors such as occlusion, appearance changes, pose variation, etc in processing. The reasons are that, Firstly, even if the naive Bayes classifier is fast in training, it is not robust concerning the noise. Secondly, the parameters are required to vary with the unique environment for accurate tracking. In this paper, we propose an improved fast compressive tracking algorithm based on online random forest (FCT-ORF for robust visual tracking. Firstly, we combine ideas with the adaptive compressive sensing theory regarding the weighted random projection to exploit both local and discriminative information of the object. The second reason is the online random forest classifier for online tracking which is demonstrated with more robust to the noise adaptively and high computational efficiency. The experimental results show that the algorithm we have proposed has a better performance in the field of occlusion, appearance changes, and pose variation than the fast compressive tracking algorithm’s contribution.

  9. Fast pattern recognition with the ATLAS L1 track trigger for the HL-LHC

    CERN Document Server

    Martensson, Mikael; The ATLAS collaboration

    2016-01-01

    A fast hardware based track trigger for high luminosity upgrade of the Large Hadron Collider (HL- LHC) is being developed in ATLAS. The goal is to achieve trigger levels in high pileup collisions that are similar or even better than those achieved at low pile-up running of LHC by adding tracking information to the ATLAS hardware trigger which is currently based on information from calorimeters and muon trigger chambers only. Two methods for fast pattern recognition are investigated. The first is based on matching tracker hits to pattern banks of simulated high momentum tracks which are stored in a custom made Associative Memory (AM) ASIC. The second is based on the Hough transform where detector hits are transformed into 2D Hough space with one variable related to track pt and one to track direction. Hits found by pattern recognition will be sent to a track fitting step which calculates the track parameters . The speed and precision of the track fitting depends on the quality of the hits selected by the patte...

  10. Fast-track surgery-an update on physiological care principles to enhance recovery

    DEFF Research Database (Denmark)

    Kehlet, Henrik

    2011-01-01

    INTRODUCTION: The concept of fast-track surgery (enhanced recovery programs) has been evolved and been documented to be successful by decreasing length of stay, morbidity and convalescence across procedures. FUTURE STRATEGIES: However, there are several possibilities for further improvement of mo...... of the components of fast-track surgery, where surgical stress, fluid and pain management are key factors. There is an urgent need for better design of studies, especially in minimal invasive surgery to achieve maximal outcome effects when integrated into the fast-track methodology....

  11. Postoperative morbidity after fast-track laparoscopic resection of rectal cancer

    DEFF Research Database (Denmark)

    Stottmeier, S; Harling, H; Wille-Jørgensen, Peer Anders

    2012-01-01

    Aim: Analysis was carried out of the nature and chronological order of early complications after fast-track laparoscopic rectal surgery with a view to optimize the short-time outcome of rectal cancer surgery. Method: 102 consecutive patients who underwent elective fast-track laparoscopic rectal......: Postoperative morbidity remains a significant problem even in the fast-track era, even in experienced surgical hands. Our results suggest that besides improvement of surgical technique further improvement of outcome lies in early recognition and proper treatment of complications and the perioperative...... cancer surgery were analysed prospectively from the Danish Colorectal Cancer Database supplemented by data from the medical records. We studied in detail the nature and chronological order of postoperative morbidity and reason for prolonged stay (>5 days). Results: Twenty-five patients (25 per cent) had...

  12. Fast simulation of the forward tracking detector of HPLUS

    International Nuclear Information System (INIS)

    Zhang Yapeng; Fan Ruirui; Fu Fen; Yue Ke; Yuan Xiaohua; Xu Huagen; Chinese Academy of Sciences, Beijing; Yao Nan; Xu Hushan; Jin Genming; Liang Jinjie; Chen Ruofu; Sun Zhiyu; Duan Limin; Xiao Zhigang; Tsinghua Univ., Beijing

    2008-01-01

    The necessity of installing a forward tracking detector stack is discussed for the Hadron Physics Lanzhou Spectrometer(HPLUS). A local tracker is developed to solve the multi-track finding problem. The track candidates are searched iteratively via Hough Transform. The fake tracks are removed by a least square fitting process. With this tracker we have studied the feasibility of pp→pp+φ(→K + K - ), a typical physical channel proposed on HPLUS. The single track momentum resolution due to the uncertainty of the positioning in FTD is 1.3%. The multiple scattering effect contributes about 20% to the momentum resolution in the FTD coverage. The width and the signal-to-background ratio of the reconstructed φ are 1.51 MeV and 4.36, respectively, taking into account the direct Kaon channel pp→pp+K + K - as background. The geometry coverage of FTD for qb events is about 85.4%. Based on the current fast simulation and estimation, the geometrical configuration of FTD meets the physical requirement of HPLUS under the current luminosity and multiplicity conditions. The tracker is applicable in the full simulation coming next and is extendable to other tracking component of HPLUS. (authors)

  13. Orchestrating care through the fast-track perspective: Orthopaedic nurses’ perceptions and experiences of providing individualised nursing care in older patients’ standardised fast-track programmes after total hip or knee replacement

    DEFF Research Database (Denmark)

    Bøttcher Berthelsen, Connie; Frederiksen, Kirsten

    2017-01-01

    The lack of individualised care in orthopaedic regimes is often explained by the extended use of patient pathways and clinical guidelines. The aim of this study was to illuminate orthopaedic nurses' perceptions and experiences of providing individual nursing care for older patients in standardised...... fast-track programmes after total hip or knee replacement. Ten semi-structured interviews were conducted with orthopaedic nurses in orthopaedic wards at three Danish hospitals between April and June of 2015. Data were analysed using manifest and latent content analysis according to Graneheim...... and Lundman. The main theme of the overall interpretation was Orchestrating care through the fast-track perspective, accompanied by three sub-themes: Identifying and legitimising relevant individual care in the fast-track programme, Struggling to fit all patients in the fast-track programme and Justifying...

  14. TRACKING TESTS FOR THE SNS FAST INJECTION BUMP POWER SUPPLY

    International Nuclear Information System (INIS)

    ENG, W.; CUTLER, R.; DEWAN, S.

    2004-01-01

    The tracking requirement of the SNS Fast Injection Bump power supplies is described. In addition to the usual tracking between the load current and the input reference of a power supply, these power supplies must also track between pairs of units under slightly different loads. This paper describes the use of a current-null test to measure tracking performances. For the actual tests, a single dummy magnet load was used to measure the tracking between the first two production units at the manufacturer's facility. Using the Yokogawa WE7000 waveform. PC-based measurement instrument, input and output waveforms are digitized and stored in data files. A program written for this application is then used to extract data from these files to construct, analyze the waveforms and characterize the power supply performance. Results of the measurements of two SNS Fast Injection Bump power supplies will be presented in this paper

  15. A blueprint for multidisciplinary fast track gastrointestinal oncology care

    NARCIS (Netherlands)

    Basta, Y.L.

    2017-01-01

    In this thesis, we have evaluated the implementation of two key concepts of the Gastro Intestinal oncology Center Amsterdam (GIOCA): multidisciplinary teams (MDT) and the fast delivery of care in fast track clinics (FTC). The first part of this thesis investigates the value of multidisciplinary

  16. Evidence-based surgical care and the evolution of fast-track surgery

    DEFF Research Database (Denmark)

    Kehlet, H.; Wilmore, D.W.

    2008-01-01

    , randomized studies, and meta-analyses, the concept of the "fast-track methodology" has uniformly provided a major enhancement in recovery leading to decreased hospital stay and with an apparent reduction in medical morbidity but unaltered "surgery-specific" morbidity in a variety of procedures. However......BACKGROUND: Optimization of postoperative outcome requires the application of evidence-based principles of care carefully integrated into a multimodal rehabilitation program. OBJECTIVE: To assess, synthesize, and discuss implementation of "fast-track" recovery programs. DATA SOURCES: Medline MBASE...... (January 1966-May 2007) and the Cochrane library (January 1966-May 2007) were searched using the following keywords: fast-track, enhanced recovery, accelerated rehabilitation, and multimodal and perioperative care. In addition, the synthesis on the many specific interventions and organizational...

  17. The Danish Head and Neck Cancer fast-track program

    DEFF Research Database (Denmark)

    Roennegaard, Anders B.; Rosenberg, Tine; Bjørndal, Kristine

    2018-01-01

    -track clinical pathway solutions. Objectives: The objectives of this study were 1) to present the setup of the head and neck cancer (HNC) fast-track program at Odense University Hospital (OUH) as an example of the Danish model and 2) to present patient characteristics, diagnostic outcome, cancer detection rate...

  18. Second Generation of a Fast-track Liver Resection Programme

    DEFF Research Database (Denmark)

    Schultz, Nicolai A; Larsen, Peter N; Klarskov, B

    2018-01-01

    was given to all patients before surgery, catheters and drains were systematically removed early, and patients were mobilized and started eating and drinking from the day of surgery. An opioid-sparing multimodal pain treatment was given for the first week. The discharge criteria were (1) pain sufficiently....... The readmission rate was 6% and the 30-day mortality zero. The LOS decreased compared to our first-generation fast-track programme with LOS 5 days. CONCLUSIONS: Fast-track principles for perioperative care and early discharge are safe even after major liver resection. The introduction of high-dose steroids...

  19. Fast Track Finding in the ILC's Silicon Detector, SiD01

    International Nuclear Information System (INIS)

    Baker, David E.

    2007-01-01

    A fast track finder is presented which, unlike its more efficient, more computationally costly O(n3) time counterparts, tracks particles in O(n) time (for n being the number of hits). Developed as a tool for processing data from the ILC's proposed SiD detector, development of this fast track finder began with that proposed by Pablo Yepes in 1996 and adjusted to accommodate the changes in geometry of the SiD detector. First, space within the detector is voxellated, with hits assigned to voxels according to their r, φ, and η coordinates. A hit on the outermost layer is selected, and a 'sample space' is built from the hits in the selected hit's surrounding voxels. The hit in the sample space with the smallest distance to the first is then selected, and the sample space recalculated for this hit. This process continues until the list of hits becomes large enough, at which point the helical circle in the x, y plane is conformally mapped to a line in the x', y' plane, and hits are chosen from the sample spaces of the previous fit by selecting the hits which fit a line to the previously selected points with the smallest χ 2 . Track finding terminates when the innermost layer has been reached or no hit in the sample space fits those previously selected to an acceptable χ 2 . Again, a hit on the outermost layer is selected and the process repeats until no assignable hits remain. The algorithm proved to be very efficient on artificial diagnostic events, such as one hundred muons scattered at momenta of 1 GeV/c to 10 GeV/c. Unfortunately, when tracking simulated events corresponding to actual physics, the track finder's efficiency decreased drastically (mostly due to signal noise), though future data cleaning programs could noticeably increase its efficiency on these events

  20. Environmental Impact Assessment of Kathmandu Terai Fast-Track

    Directory of Open Access Journals (Sweden)

    Padam Kanta Dahal

    2014-12-01

    Full Text Available  Road transport is dominant necessity for the overall economic development of any nation. In case of Nepal, an easy access between the Capital City and Terai, the store-house of the country and is very necessary. To facilitate this promotion of an improved core road network, Government of Nepal has launched the Kathmandu Terai Fast Track Project. Many concerned personalities and sectors had considered this project to be number one in the list of seventeen projects of national pride declared by the government. The main objective of this study was to identify the impacts of proposed project implementation on physical, biological, socio-economic and cultural environment of the project area and propose mitigation measures to avoid or mitigate such impacts. Primary information collection and secondary data review was the source of data with cross sectional descriptive study design. Data was taken purposively in the project affected area. Length of 72.6 km fast track from Kathmandu – Lalitpur – Makawanpur and up to Nijgadh in Bara district to link with the East West Highway will be of four lanes with 50 m on each side. The project was proposed to have 96 bridges big or small; 1.6 km long tunnel will be built in Thingan of Makawanpur on public-private partnership. It had projected costs of more than NRs 250 million. The impacts on land use will be on about 30km of agricultural land, 43km of forests and about 3km of other land uses, bridges etc. in the main alignment. The impacts on human life will mainly be in villages near the alignment. There are 38 villages within about 50m of the main alignment. The project can be continued with minimum of environmental degradation by applying the mitigation measures. Nation has been investing a lot of resources. Upon the completion of the fast track, the distance and time to reach the capital city from Terai will come down to only 1.5 hours and will transform the capital, eastern Terai and the country as a

  1. Pathogenesis of morbidity after fast-track laparoscopic colonic cancer surgery

    DEFF Research Database (Denmark)

    Stottmeier, S; Harling, H; Wille-Jørgensen, P

    2011-01-01

    AIM: Analysis of the nature and time course of early complications after laparoscopic colonic surgery is required to allow rational strategies for their prevention and management. METHOD: One hundred and four consecutive patients who underwent elective fast-track laparoscopic colonic cancer surgery...... occurred in 14 patients, of which four were preceded by medical complications. Three patients had only medical complications. Median length of stay was 3 days (range 1-44). CONCLUSION: Further improvement of outcomes after fast-track laparoscopic colonic surgery might be obtained by improved surgical...

  2. Fast-track rehabilitation in elective colorectal surgery patients: a prospective clinical and immunological single-centre study.

    Science.gov (United States)

    Wichmann, Matthias W; Eben, Ricarda; Angele, Martin K; Brandenburg, Franzis; Goetz, Alwin E; Jauch, Karl-Walter

    2007-07-01

    Recent clinical data indicate that fast-track surgery (multimodal rehabilitation) leads to shorter postoperative length of hospital stay, faster recovery of gastrointestinal function as well as reduced morbidity and mortality rates. To date, no study has focused on the effects of fast-track surgery on postoperative immune function. This study was initiated to determine whether fast-track rehabilitation results in improved clinical and immunological outcome of patients undergoing colorectal surgery. Forty patients underwent either conventional or fast-track rehabilitation after colorectal surgery. In addition to clinical parameters (return of gastrointestinal function, food intake, pain score, complication rates and postoperative length of stay), we determined parameters of perioperative immunity by flow cytometry (lymphocyte subgroups) and enzyme-linked immunosorbent assay (interleukin-6). Our findings indicate a better-preserved cell-mediated immune function (T cells, T-helper cells, natural killer cells) after fast-track rehabilitation, whereas the pro-inflammatory response (C-reactive protein, interleukin-6) was unchanged in both study groups. Furthermore, we detected a significantly faster return of gastrointestinal function (first bowel movement P<0.001, food intake P<0.05), significantly reduced pain scores in the postoperative course (P < 0.05) and a significantly shorter length of postoperative stay (P<0.001) in patients undergoing fast-track rehabilitation. Fast-track rehabilitation after colorectal surgery results in better-preserved cell-mediated immunity when compared with conventional postoperative care. Furthermore, patients undergoing fast-track rehabilitation suffer from less pain and have a faster return of gastrointestinal function in the postoperative course. In addition, postoperative length of hospital stay was significantly shorter in fast-track patients.

  3. How Does the Fast Track Intervention Prevent Adverse Outcomes in Young Adulthood?

    Science.gov (United States)

    Sorensen, Lucy C; Dodge, Kenneth A

    2016-01-01

    Numerous studies have shown that childhood interventions can foster improved outcomes in adulthood. Less well understood is precisely how-that is, through which developmental pathways-these interventions work. This study assesses mechanisms by which the Fast Track project (n = 891), a randomized intervention in the early 1990s for high-risk children in four communities (Durham, NC; Nashville, TN; rural PA; and Seattle, WA), reduced delinquency, arrests, and general and mental health service utilization in adolescence through young adulthood (ages 12-20). A decomposition of treatment effects indicates that about a third of Fast Track's impact on later crime outcomes can be accounted for by improvements in social and self-regulation skills during childhood (ages 6-11), such as prosocial behavior, emotion regulation, and problem solving. These skills proved less valuable for the prevention of general and mental health problems. © 2015 The Authors. Child Development © 2015 Society for Research in Child Development, Inc.

  4. The role of pain for early rehabilitation in fast track total knee arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten Tange; Myhrmann, Lis

    2010-01-01

    To investigate the relationship between early functional mobility and pain intensity in a fast track program after total knee arthroplasty (TKA).......To investigate the relationship between early functional mobility and pain intensity in a fast track program after total knee arthroplasty (TKA)....

  5. Restoring integrity—A grounded theory of coping with a fast track surgery programme

    Directory of Open Access Journals (Sweden)

    Lene Bastrup Jørgensen

    2016-01-01

    Full Text Available Aims and objectives: The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Background: Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. Design: The study design used classical grounded theory. Methods: The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Results: Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients’ main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. Conclusion: In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme.

  6. Restoring integrity--A grounded theory of coping with a fast track surgery programme.

    Science.gov (United States)

    Jørgensen, Lene Bastrup; Fridlund, Bengt

    2016-01-01

    The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. The study design used classical grounded theory. The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients' main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme.

  7. Restoring integrity—A grounded theory of coping with a fast track surgery programme

    Science.gov (United States)

    Jørgensen, Lene Bastrup; Fridlund, Bengt

    2016-01-01

    Aims and objectives The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Background Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. Design The study design used classical grounded theory. Methods The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Results Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients’ main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. Conclusion In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme. PMID:26751199

  8. Fast-track program vs traditional care in surgery for gastric cancer.

    Science.gov (United States)

    Chen, Zhi-Xing; Liu, Ae-Huey Jennifer; Cen, Ying

    2014-01-14

    To systematically review the evidence for the effectiveness of fast-track program vs traditional care in laparoscopic or open surgery for gastric cancer. PubMed, Embase and the Cochrane library databases were electronically searched for published studies between January 1995 and April 2013, and only randomized trials were included. The references of relevant studies were manually searched for further studies that may have been missed. Search terms included "gastric cancer", "fast track" and "enhanced recovery". Five outcome variables were considered most suitable for analysis: postoperative hospital stay, medical cost, duration to first flatus, C-reactive protein (CRP) level and complications. Postoperative hospital stay was calculated from the date of operation to the date of discharge. Fixed effects model was used for meta-analysis. Compared with traditional care, fast-track program could significantly decrease the postoperative hospital stay [weighted mean difference (WMD) = -1.19, 95%CI: -1.79--0.60, P = 0.0001, fixed model], duration to first flatus (WMD = -6.82, 95%CI: -11.51--2.13, P = 0.004), medical costs (WMD = -2590, 95%CI: -4054--1126, P = 0.001), and the level of CRP (WMD = -17.78, 95%CI: -32.22--3.35, P = 0.0001) in laparoscopic surgery for gastric cancer. In open surgery for gastric cancer, fast-track program could also significantly decrease the postoperative hospital stay (WMD = -1.99, 95%CI: -2.09--1.89, P = 0.0001), duration to first flatus (WMD = -12.0, 95%CI: -18.89--5.11, P = 0.001), medical cost (WMD = -3674, 95%CI: -5025--2323, P = 0.0001), and the level of CRP (WMD = -27.34, 95%CI: -35.42--19.26, P = 0.0001). Furthermore, fast-track program did not significantly increase the incidence of complication (RR = 1.39, 95%CI: 0.77-2.51, P = 0.27, for laparoscopic surgery; and RR = 1.52, 95%CI: 0.90-2.56, P = 0.12, for open surgery). Our overall results suggested that compared with traditional care, fast-track program could result in shorter

  9. Successful integration of fast track projects into turnarounds

    Energy Technology Data Exchange (ETDEWEB)

    Williams, J. Patrick; Loureiro, Ramon C. [KBC Advanced Technologies, Surrey (United Kingdom)

    2012-07-01

    Fast track projects can provide quick wins and competitive advantage. However, in most cases the implementation of these projects requires a shutdown for installing the necessary tie-ins or integration into an upcoming turnaround (TA). Depending on the nature of the project and complexity of the TA, the integration can be seamless or result in cost or duration overruns and safety incidents. The risk of such overruns and safety incidents increases with the amount of project work to be integrated into the operations, maintenance and inspection schedules to be executed during the TA. The risk further increases with TA size and other factors. If not planned and scheduled properly and in a timely fashion, capital projects, in particular fast track projects trying to take advantage of an upcoming TA, can severely impact both TA performance, and the safety and reliability of the facility until the next opportunity for eliminating the defects introduced during the TA. Successful TAs are those delivered in a safe, on time, on budget manner, and with the quality standards needed for a leak-free start-up and a safe and reliable operation over the next run cycle. This paper discusses the key elements that are required to minimize the TA risks derived from the inclusion of fast track projects and how to establish the cut off criteria to either cancel or defer the project, or delay the TA in order to balance TA scope freeze and the case for compelling economics.(author)

  10. Perioperative strategy in colonic surgery; LAparoscopy and/or FAst track multimodal management versus standard care (LAFA trial

    Directory of Open Access Journals (Sweden)

    Swart Annemiek

    2006-11-01

    Full Text Available Abstract Background Recent developments in large bowel surgery are the introduction of laparoscopic surgery and the implementation of multimodal fast track recovery programs. Both focus on a faster recovery and shorter hospital stay. The randomized controlled multicenter LAFA-trial (LAparoscopy and/or FAst track multimodal management versus standard care was conceived to determine whether laparoscopic surgery, fast track perioperative care or a combination of both is to be preferred over open surgery with standard care in patients having segmental colectomy for malignant disease. Methods/design The LAFA-trial is a double blinded, multicenter trial with a 2 × 2 balanced factorial design. Patients eligible for segmental colectomy for malignant colorectal disease i.e. right and left colectomy and anterior resection will be randomized to either open or laparoscopic colectomy, and to either standard care or the fast track program. This factorial design produces four treatment groups; open colectomy with standard care (a, open colectomy with fast track program (b, laparoscopic colectomy with standard care (c, and laparoscopic surgery with fast track program (d. Primary outcome parameter is postoperative hospital length of stay including readmission within 30 days. Secondary outcome parameters are quality of life two and four weeks after surgery, overall hospital costs, morbidity, patient satisfaction and readmission rate. Based on a mean postoperative hospital stay of 9 +/- 2.5 days a group size of 400 patients (100 each arm can reliably detect a minimum difference of 1 day between the four arms (alfa = 0.95, beta = 0.8. With 100 patients in each arm a difference of 10% in subscales of the Short Form 36 (SF-36 questionnaire and social functioning can be detected. Discussion The LAFA-trial is a randomized controlled multicenter trial that will provide evidence on the merits of fast track perioperative care and laparoscopic colorectal surgery in

  11. Fast and Practical Head Tracking in Brain Imaging with Time-of-Flight Camera

    DEFF Research Database (Denmark)

    Wilm, Jakob; Olesen, Oline Vinter; Jensen, Rasmus Ramsbøl

    2013-01-01

    scanners. Particularly in MRI and PET, the newest generation of TOF cameras could become a method of tracking small and large scale patient movement in a fast and user friendly way required in clinical environments. We present a novel methodology for fast tracking from TOF point clouds without the need...

  12. Interactive and automated systems for nuclear track measurements with applications to fast neutron dosimetry

    International Nuclear Information System (INIS)

    Roberts, J.H.; Gold, R.; McNeece, J.P.; Preston, C.C.; Ruddy, F.H.

    1983-12-01

    Interactive and automatic track measuring systems have been developed primarily for fast neutron dosimetry in and around reactors. The interactive system is used for proton recoil measurements in nuclear research emulsions and the automatic systems for counting fission fragment tracks in Muscovite mica. The status of these systems, along with illustrative applications, are presented, particularly with regard to their relationship to neutron personnel dosimetry. 16 references, 12 figures

  13. Serious renal and urological complications in fast-track primary total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Bjerregaard, Lars S; Jorgensen, Christoffer C; Kehlet, Henrik

    2016-01-01

    of stay > 4 days or 30-day readmissions after fast-track THA and TKA, we conducted a detailed observational study based upon prospectively collected pre-operative data and a complete 30-day follow-up on complications and re-admissions in a unselected cohort of 8,804 consecutive fast-track THAs and TKAs......BACKGROUND: Overall medical complications have been reduced after fast-track total hip (THA) and knee arthroplasty (TKA), but data on specific renal and urological (RU) complications are limited. METHODS: To describe the incidence and consequences of serious RU complications resulting in length...

  14. Perioperative strategy in colonic surgery; LAparoscopy and/or FAst track multimodal management versus standard care (LAFA trial).

    NARCIS (Netherlands)

    Wind, J.; Hofland, J.; Preckel, B.; Hollman, M.W.; Bossuyt, P.M.M.; Gouma, D.J.; Berge Henegouwen, M.I.; Fuhring, J.W.; Dejong, C.H.C.; Dam, R.M. van; Cuesta, M.A.; Noordhuis, A.; Jong, D. de; Zalingen, E. van; Engel, A.F.; Goei, T.H.; Stoppelaar, I.E. de; Tets, W.F. van; Wagensveld, B.A. van; Swart, A.; Elsen, M.J.L.J. van den; Gerhards, M.F.; Wit, L.Th. De; Siepel, M.A.M.; Geloven, A.A.W. van; Juttmann, J.-W.; Clevers, J.C.; Bemelman, W.A.

    2006-01-01

    BACKGROUND: Recent developments in large bowel surgery are the introduction of laparoscopic surgery and the implementation of multimodal fast track recovery programs. Both focus on a faster recovery and shorter hospital stay.The randomized controlled multicenter LAFA-trial (LAparoscopy and/or FAst

  15. Perioperative strategy in colonic surgery; LAparoscopy and/or FAst track multimodal management versus standard care (LAFA trial)

    NARCIS (Netherlands)

    Wind, Jan; Hofland, Jan; Preckel, Benedikt; Hollmann, Markus W.; Bossuyt, Patrick M. M.; Gouma, Dirk J.; van Berge Henegouwen, Mark I.; Fuhring, Jan Willem; Dejong, Cornelis H. C.; van Dam, Ronald M.; Cuesta, Miguel A.; Noordhuis, Astrid; de Jong, Dick; van Zalingen, Edith; Engel, Alexander F.; Goei, T. Hauwy; de Stoppelaar, I. Erica; van Tets, Willem F.; van Wagensveld, Bart A.; Swart, Annemiek; van den Elsen, Maarten J. L. J.; Gerhards, Michael F.; de Wit, Laurens Th; Siepel, Muriel A. M.; van Geloven, Anna A. W.; Juttmann, Jan-Willem; Clevers, Wilfred; Bemelman, Willem A.

    2006-01-01

    BACKGROUND: Recent developments in large bowel surgery are the introduction of laparoscopic surgery and the implementation of multimodal fast track recovery programs. Both focus on a faster recovery and shorter hospital stay.The randomized controlled multicenter LAFA-trial (LAparoscopy and/or FAst

  16. Comparison of remifentanil and low-dose fentanyl for fast-track cardiac anesthesia

    DEFF Research Database (Denmark)

    Khanykin, Boris; Siddiqi, Rizwan; Jensen, Per F

    2013-01-01

    BACKGROUND: Different anesthetic techniques have been used for fast tracking in cardiac anesthesia. Remifentanil, with its unique pharmacokinetic profile, could be an ideal drug for fast tracking. Possible limitations of remifentanil are rapid onset of postoperative pain after discontinuation...... of the drug infusion, which may increase the risk of an ischemic event. We conducted this randomized study to compare the efficacy of remifentanil versus low doses of fentanyl in fast-track cardiac anesthesia. It has been hypothesized that remifentanil would provide a safe anesthesia with no impact...... anesthesia. The study was designed as a prospective randomized study. The primary outcomes were changes in the cardiac index and creatine kinase MB fraction (CKMB), extubation times, mobilization times, and lengths of stay in the intensive care unit (ICU) and the hospital. Frequency of myocardial infarction...

  17. PUC fast track nips returns

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    In the first of what it says will be annual cost-of-capital proceedings to set returns on equity and rates of return on rate base for electric utilities, the California Public Utilities Commission (PUC) lowered from 1989 levels the 1990 returns on common equity (ROE) and rates of return (ROR) for the state's four major investor-owned electric utilities. Under this fast-track procedure, by May 8 of every year, utilities will have to file an application for rate adjustments that reflect their projected costs of capital for the following year

  18. Trevino Project: a fast-track approach for a small construction project

    International Nuclear Information System (INIS)

    Schick, C.J.; Lynn, N.S.

    1982-01-01

    The approach to a construction project can vary according to the size, location, and degree of difficulty associated with the project. This paper deals with one approach that can be taken to a small construction project, the fast-track approach. A small construction project can be defined as a project having less than $20 million capital cost or a project with a low degree of difficulty. This approach is very applicable to in-situ leaching uranium projects, small precious metal operations, etc. The approach to the small project is that of fast-tracking the project in order to minimize the time over which capital expenditure occurs and also to reduce the indirect costs of field expense, construction supplies, construction equipment, etc. In order to fast-track a project it is necessary to do a very precise job on the preliminary phases of the project such as preliminary engineering, plant site location, environmental permits, etc. 2 figures, 2 tables

  19. The risk of manipulation under anesthesia due to unsatisfactory knee flexion after fast-track total knee arthroplasty

    DEFF Research Database (Denmark)

    Wied, Christian; Thomsen, Morten G; Kallemose, Thomas

    2015-01-01

    BACKGROUND: Fast-track TKA has significantly shortened the time available for physiotherapists to optimize knee ROM before discharge. Safety aspects concerning knee stiffness and the need for manipulation in a fast-track setting need to be illuminated. The study aims were to analyze if fast-track...

  20. Time-driven Activity-based Cost of Fast-Track Total Hip and Knee Arthroplasty

    DEFF Research Database (Denmark)

    Andreasen, Signe E; Holm, Henriette B; Jørgensen, Mira

    2017-01-01

    this between 2 departments with different logistical set-ups. METHODS: Prospective data collection was analyzed using the time-driven activity-based costing method (TDABC) on time consumed by different staff members involved in patient treatment in the perioperative period of fast-track THA and TKA in 2 Danish...... orthopedic departments with standardized fast-track settings, but different logistical set-ups. RESULTS: Length of stay was median 2 days in both departments. TDABC revealed minor differences in the perioperative settings between departments, but the total cost excluding the prosthesis was similar at USD......-track methodology, the result could be a more cost-effective pathway altogether. As THA and TKA are potentially costly procedures and the numbers are increasing in an economical limited environment, the aim of this study is to present baseline detailed economical calculations of fast-track THA and TKA and compare...

  1. Readmissions after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B

    2010-01-01

    With the implementation of fast-track surgery with optimization of both logistical and clinical features, the postoperative convalescence has been reduced as functional milestones have been achieved earlier and consequently length of stay (LOS) in hospital has been reduced. However, it has been...

  2. Fast-Track Cleanup at Closing DoD Installations

    Science.gov (United States)

    The Fast-Track Cleanup program strives to make parcels available for reuse as quickly as possible by the transfer of uncontaminated or remediated parcels, the lease of contaminated parcels where cleanup is underway, or the 'early transfer' of contaminated property undergoing cleanup.

  3. Patient-reported outcome after fast-track knee arthroplasty

    DEFF Research Database (Denmark)

    Larsen, Kristian; Hansen, Torben B; Søballe, Kjeld

    2012-01-01

    PURPOSE: The purpose of this study was to describe patient-related functional outcomes after fast-track total knee arthroplasty and unicompartmental knee arthroplasty. Furthermore, we wanted to assess physical areas where an additional need for rehabilitation could be identified, and finally, we...

  4. The Effects of the Fast Track Preventive Intervention on the Development of Conduct Disorder across Childhood

    Science.gov (United States)

    Child Development, 2011

    2011-01-01

    The impact of the Fast Track intervention on externalizing disorders across childhood was examined. Eight hundred-ninety-one early-starting children (69% male; 51% African American) were randomly assigned by matched sets of schools to intervention or control conditions. The 10-year intervention addressed parent behavior-management, child social…

  5. Design of a Hardware Track Finder (Fast Tracker) for the ATLAS Trigger

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00010976; Albicocco, P.; Alison, J.; Ancu, L.S.; Anderson, J.; Andari, N.; Andreani, A.; Andreazza, A.; Annovi, A.; Antonelli, M.; Asbah, N.; Atkinson, M.; Baines, J.; Barberio, E.; Beccherle, R.; Beretta, M.; Bertolucci, F.; Biesuz, N.V.; Blair, R.; Bogdan, M.; Boveia, A.; Britzger, D.; Bryant, P.; Burghgrave, B.; Calderini, G.; Camplani, A.; Cavasinni, V.; Chakraborty, D.; Chang, P.; Cheng, Y.; Citraro, S.; Citterio, M.; Crescioli, F.; Dawe, N.; Dell'Orso, M.; Donati, S.; Dondero, P.; Drake, G.; Gadomski, S.; Gatta, M.; Gentsos, C.; Giannetti, P.; Gkaitatzis, S.; Gramling, J.; Howarth, J.W.; Iizawa, T.; Ilic, N.; Jiang, Z.; Kaji, T.; Kasten, M.; Kawaguchi, Y.; Kim, Y.K.; Kimura, N.; Klimkovich, T.; Kolb, M.; Kordas, K.; Krizka, K.; Kubota, T.; Lanza, A.; Li, H.L.; Liberali, V.; Lisovyi, M.; Liu, L.; Love, J.; Luciano, P.; Luongo, C.; Magalotti, D.; Maznas, I.; Meroni, C.; Mitani, T.; Nasimi, H.; Negri, A.; Neroutsos, P.; Neubauer, M.; Nikolaidis, S.; Okumura, Y.; Pandini, C.; Petridou, C.; Piendibene, M.; Proudfoot, J.; Rados, P.; Roda, C.; Rossi, E.; Sakurai, Y.; Sampsonidis, D.; Saxon, J.; Schmitt, S.; Schoening, A.; Shochet, M.; Shojaii, S.; Soltveit, H.; Sotiropoulou, C.L.; Stabile, A.; Swiatlowski, M.; Tang, F.; Taylor, P.T.; Testa, M.; Tompkins, L.; Vercesi, V.; Volpi, G.; Wang, R.; Watari, R.; Webster, J.; Wu, X.; Yorita, K.; Yurkewicz, A.; Zeng, J.C.; Zhang, J.; Zou, R.

    2016-01-01

    The use of tracking information at the trigger level in the LHC Run II period is crucial for the trigger an data acquisition (TDAQ) system and will be even more so as contemporary collisions that occur at every bunch crossing will increase in Run III. The Fast TracKer (FTK) is part of the ATLAS trigger upgrade project; it is a hardware processor that will provide every Level-1 accepted event (100 kHz) and within 100$\\mu$s, full tracking information for tracks with momentum as low as 1 GeV. Providing fast, extensive access to tracking information, with resolution comparable to the offline reconstruction, FTK will help in precise detection of the primary and secondary vertices to ensure robust selections and improve the trigger performance.

  6. Convalescence after colonic resection with fast-track versus conventional care

    DEFF Research Database (Denmark)

    Hjort Jakobsen, D; Sonne, E; Basse, L

    2004-01-01

    BACKGROUND: Multi-modal rehabilitation programmes may improve early postoperative body composition, pulmonary function, exercise capacity, and reduce hospital stay. So far, no data are available on convalescence after discharge. AIM: The objectives were to compare convalescence data (fatigue, sleep...... vs. 8 days in the fast-track vs. conventional care group, respectively (p sleep were increased in the conventional care group when compared with the fast-track group (p ... results in earlier resumption of normal activities with reduced fatigue and need for sleep postoperatively compared to conventional care, and without increased need for nursing care or visits to general practitioners. However, readmissions may occur more frequently....

  7. FAST TRACK SURGERY IN TOTAL KNEE ARTHROPLASTY - A REVIEW.

    Directory of Open Access Journals (Sweden)

    Pencho Kosev

    2015-08-01

    Full Text Available The number of orthopedic surgeons who are convinced in the need for significant changes in planned total knee arthroplasty (TKA is increasing slowly and steadily. A new approach to pain control has been developed over the past 10-15 years, and the introduction of techniques to reduce perioperative stress, and the use of minimally invasive surgical techniques can help limit postoperative complications and shorten recovery time. This type of optimization is regarded as Fast-track Care program, where improved healing process is particularly useful to comorbid patients.

  8. Why still in hospital after fast-track hip and knee arthroplasty?

    DEFF Research Database (Denmark)

    Husted, Henrik; Lunn, Troels H; Troelsen, Anders

    2011-01-01

    Background and purpose Length of stay (LOS) following total hip and knee arthroplasty (THA and TKA) has been reduced to about 3 days in fast-track setups with functional discharge criteria. Earlier studies have identified patient characteristics predicting LOS, but little is known about specific...... reasons for being hospitalized following fast-track THA and TKA. Patients and methods To determine clinical and logistical factors that keep patients in hospital for the first postoperative 24-72 hours, we performed a cohort study of consecutive, unselected patients undergoing unilateral primary THA (n...

  9. Fast Compressive Tracking.

    Science.gov (United States)

    Zhang, Kaihua; Zhang, Lei; Yang, Ming-Hsuan

    2014-10-01

    It is a challenging task to develop effective and efficient appearance models for robust object tracking due to factors such as pose variation, illumination change, occlusion, and motion blur. Existing online tracking algorithms often update models with samples from observations in recent frames. Despite much success has been demonstrated, numerous issues remain to be addressed. First, while these adaptive appearance models are data-dependent, there does not exist sufficient amount of data for online algorithms to learn at the outset. Second, online tracking algorithms often encounter the drift problems. As a result of self-taught learning, misaligned samples are likely to be added and degrade the appearance models. In this paper, we propose a simple yet effective and efficient tracking algorithm with an appearance model based on features extracted from a multiscale image feature space with data-independent basis. The proposed appearance model employs non-adaptive random projections that preserve the structure of the image feature space of objects. A very sparse measurement matrix is constructed to efficiently extract the features for the appearance model. We compress sample images of the foreground target and the background using the same sparse measurement matrix. The tracking task is formulated as a binary classification via a naive Bayes classifier with online update in the compressed domain. A coarse-to-fine search strategy is adopted to further reduce the computational complexity in the detection procedure. The proposed compressive tracking algorithm runs in real-time and performs favorably against state-of-the-art methods on challenging sequences in terms of efficiency, accuracy and robustness.

  10. Fast tracking in adult cardiac surgery at Pakistan Institute of Medical Sciences

    International Nuclear Information System (INIS)

    Ahmed, N.; Khan, F.; Zahoor, M.; Rafique, M.; Faisal, M.

    2010-01-01

    Background: Early extubation after cardiac operation is an important aspect of fast-track cardiac anaesthesia. The length of stay in ICU limits utilisation of operation theatre in cardiac surgery. Increasing cost, limited resources, and newer surgical strategies have stimulated effectiveness of all routines in cardiac surgery, anaesthesia, and intensive care. Aim of this study was to determine the feasibility of fast-tracking in adult cardiac surgery and its effects on post operative recovery in our setup. Methods: This descriptive study was conducted over 14 months between Jul 16, 2007 to Sep 16, 2008. All the open heart cases were included unless absolute contraindications were there. We applied the rapid recovery protocol adopted from Oslo Hospital Norway in an attempt to achieve fast-tracking in our setup. Results: Two-hundred-seventy-four consecutive cases out of 400 operated cases were included in this study. Mean age was 47.69 +- 15.11 years, 27.7% were females, 5.8% were emergency cases, 5.1% were COPD, 11.1% were atrial fibrillation, and 6.9% were NYHA class-III cases. CABG was done in 66.1% cases and mean CPB-time was 75.92 +- 16.20 min. Mean Ventilation-time was 4.47+-4.48 hrs., 86% patients were fast-tracked to be extubated within 6 hours, and 85.4% patients remained free of post-op complications. Six (2.2%) re-intubatIions, 2.6% arrhythmias, 6.6% pleural effusions and 2.2% consolidation were observed post-operatively. Mean ICU stay was 2.49 +- 0.95 days and in-hospital mortality was 2.2%. Conclusion: Fast-tracking with extubation within 6 hours is feasible approach which minimises the post-operative complications significantly in adult cardiac surgical patients. (author)

  11. A fast neutron detector with IP by track measurement

    International Nuclear Information System (INIS)

    Miao Zhengqiang; Yang Jun; Zhang Qiang; Zhao Xiangfeng; Wang Daohua

    2004-01-01

    Imaging Plate(IP) is very sensitive to electric particles, especially to heavy ions. As we know, the recoiling protons are produced while fast neutrons scattered in light material containing hydrogen. When the recoiling proton enters in the sensitive layer of IP, a track will be recorded by IP. In this paper, a fast neutron detector based on IP and (n, p) reaction is described in detail, the detector's efficiency is studied also. (authors)

  12. Fast track trigger processor for the OPAL detector at LEP

    Energy Technology Data Exchange (ETDEWEB)

    Carter, A A; Carter, J R; Ward, D R; Heuer, R D; Jaroslawski, S; Wagner, A

    1986-09-20

    A fast hardware track trigger processor being built for the OPAL experiment is described. The processor will analyse data from the central drift chambers of OPAL to determine whether any tracks come from the interaction region, and thereby eliminate background events. The processor will find tracks over a large angular range, vertical strokecos thetavertical stroke < or approx. 0.95. The design of the processor is described, together with a brief account of its hardware implementation for OPAL. The results of feasibility studies are also presented.

  13. The ATLAS Fast Tracker Processing Units - track finding and fitting

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00384270; The ATLAS collaboration; Alison, John; Ancu, Lucian Stefan; Andreani, Alessandro; Annovi, Alberto; Beccherle, Roberto; Beretta, Matteo; Biesuz, Nicolo Vladi; Bogdan, Mircea Arghir; Bryant, Patrick; Calabro, Domenico; Citraro, Saverio; Crescioli, Francesco; Dell'Orso, Mauro; Donati, Simone; Gentsos, Christos; Giannetti, Paola; Gkaitatzis, Stamatios; Gramling, Johanna; Greco, Virginia; Horyn, Lesya Anna; Iovene, Alessandro; Kalaitzidis, Panagiotis; Kim, Young-Kee; Kimura, Naoki; Kordas, Kostantinos; Kubota, Takashi; Lanza, Agostino; Liberali, Valentino; Luciano, Pierluigi; Magnin, Betty; Sakellariou, Andreas; Sampsonidis, Dimitrios; Saxon, James; Shojaii, Seyed Ruhollah; Sotiropoulou, Calliope Louisa; Stabile, Alberto; Swiatlowski, Maximilian; Volpi, Guido; Zou, Rui; Shochet, Mel

    2016-01-01

    The Fast Tracker is a hardware upgrade to the ATLAS trigger and data-acquisition system, with the goal of providing global track reconstruction by the start of the High Level Trigger starts. The Fast Tracker can process incoming data from the whole inner detector at full first level trigger rate, up to 100 kHz, using custom electronic boards. At the core of the system is a Processing Unit installed in a VMEbus crate, formed by two sets of boards: the Associative Memory Board and a powerful rear transition module called the Auxiliary card, while the second set is the Second Stage board. The associative memories perform the pattern matching looking for correlations within the incoming data, compatible with track candidates at coarse resolution. The pattern matching task is performed using custom application specific integrated circuits, called associative memory chips. The auxiliary card prepares the input and reject bad track candidates obtained from from the Associative Memory Board using the full precision a...

  14. Implementation of the scientific evidence into daily practice - example from fast-track colonic cancer surgery

    DEFF Research Database (Denmark)

    Hammer, J.; Harling, H.; Wille-Jorgensen, P.

    2008-01-01

    Objective To report the implementation and results of fast-track surgery for colonic cancer in the daily routine. Method A total of 131 consecutive patients scheduled for elective colonic cancer resections entered a fast-track perioperative course after thorough information. The regimen contained...

  15. ATLAS Fast Tracker Status and Tracking at High luminosity LHC

    CERN Document Server

    Ilic, Nikolina; The ATLAS collaboration

    2018-01-01

    The LHC’s increase in centre of mass energy and luminosity in 2015 makes controlling trigger rates with high efficiency challenging. The ATLAS Fast TracKer (FTK) is a hardware processor built to reconstruct tracks at a rate of up to 100 kHz and provide them to the high level trigger. The FTK reconstructs tracks by matching incoming detector hits with pre-defined track patterns stored in associative memory on custom ASICs. Inner detector hits are fit to these track patterns using modern FPGAs. This talk describes the electronics system used for the FTK’s massive parallelization. The installation, commissioning and running of the system is happening in 2016, and is detailed in this talk. Tracking at High luminosity LHC is also presented.

  16. L0 Confirmation with fast, Tsa based tracking in the T-stations

    CERN Document Server

    Albrecht, J; Terrier, H

    2007-01-01

    A fast tracking algorithm to confirm the high $p_T$ L0 trigger objects with tracks from the T-stations is presented. The L0 trigger candidate is used to define a search window to a potential track. Using this, a seeded track search is performed. The track finding algorithm is based on the \\textit{TsaSeeding} algorithm~\\cite{bib:Tsa}. The efficiency to confirm a true L0 trigger signal is around 96\\%, the momentum can be measured up to $\\Delta p/p$=3\\%.

  17. SMEs in Energy: Are they the parallel fast track for electrification of Africa?

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Rahman, Mohamed

    2010-09-15

    The African continent is suffering from a chronic energy shortage that hiders its development. The conventional wisdom is to put the Mega projects under focus. However, a parallel fast track for the energy as an SME business may bring faster results to the continent. To that end, this paper presents proposed steps to promote the concept within the continent.

  18. Low manipulation prevalence following fast-track total knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Jørgensen, Christoffer C.; Gromov, Kirill

    2015-01-01

    BACKGROUND AND PURPOSE: Postoperative joint stiffness following total knee arthroplasty (TKA) may compromise the outcome and necessitate manipulation. Previous studies have not been in a fast-track setting with optimized pain treatment, early mobilization, and short length of stay (LOS), which ma...

  19. After colonic surgery: The lived experience of participating in a fast-track programme

    DEFF Research Database (Denmark)

    Norlyk, Annelise; Harder, Ingegerd

    2009-01-01

    Postoperative recovery can be accelerated and hospitalization reduced through fast-track programmes. However, documented knowledge is limited and primarily focusing on a medical perspective whereas the patients' perspective lacks documentation. This study describes the lived experience of partici......Postoperative recovery can be accelerated and hospitalization reduced through fast-track programmes. However, documented knowledge is limited and primarily focusing on a medical perspective whereas the patients' perspective lacks documentation. This study describes the lived experience...

  20. A modified fast-track program for pancreatic surgery: a prospective single-center experience.

    Science.gov (United States)

    di Sebastiano, Pierluigi; Festa, Leonardina; De Bonis, Antonio; Ciuffreda, Andrea; Valvano, Maria Rosa; Andriulli, Angelo; di Mola, F Francesco

    2011-03-01

    The objective of this study is to evaluate the impact of a fast-track protocol in a high-volume center for patients with pancreatic disorders. The concept of fast-track surgery allowing accelerated postoperative recovery is accepted in colorectal surgery, but efficacy data are only preliminary for patients undergoing major pancreatic surgery. We aimed to evaluate the impact of a modified fast-track protocol in a high-volume center for patients with pancreatic disorders. Between February 2005 and January 2010, 145 subjects had resective pancreatic surgery and were enrolled in the program. Essential features of the program were no preanaesthetic medication, upper and lower air-warming device, avoidance of excessive i.v. fluids perioperatively, effective control of pain, early reinstitution of oral feeding, and immediate mobilization and restoration of bowel function following surgery. Outcome measures were postoperative complications such as pancreatic fistula, delayed gastric emptying, biliary leak, intra-abdominal abscess, post-pancreatectomy hemorrhage, acute pancreatitis, wound infection, 30-day mortality, postoperative hospital stay, and readmission rates. On average, patients were discharged on postoperative day 10 (range 6-69), with a 30-day readmission rate of 6.2%. Percentage of patients with at least one complication was 38.6%. Pancreatic anastomotic leakage occurred in seven of 101 pancreatico-jejunostomies, and biliary leak in three of 109 biliary jejunostomies. Postoperative hemorrhage occurred in ten (6.9%) patients and wound infection in nine (6.2%) cases. In-hospital mortality was 2.7%. Fast-track parameters, such as normal food and first stool, correlated significantly with early discharge (jaundice, and resumption of normal diet by the 5th postoperative day were independent factors of early discharge. Fast-track programs are feasible, easy, and also applicable for patients undergoing a major surgery such as pancreatic resection.

  1. Orthostatic intolerance during early mobilization after fast-track hip arthroplasty

    DEFF Research Database (Denmark)

    Jans, O; Bundgaard-Nielsen, M; Solgaard, S

    2012-01-01

    has not been established after THA. This study evaluated the cardiovascular response and tissue oxygenation to mobilization before and after surgery in relation to OI in fast-track THA patients. METHODS: /st>OI and the cardiovascular response to standing were evaluated with a standardized mobilization......BACKGROUND: /st>Early postoperative mobilization is a cornerstone in fast-track total hip arthroplasty (THA), but postoperative orthostatic intolerance (OI) may delay early recovery or lead to fainting, falls, and prosthesis dislocation or fracture. However, the prevalence and pathophysiology of OI...... protocol, before, 6, and 24 h after surgery in 26 patients undergoing THA with spinal anaesthesia and an opioid-sparing analgesic regime. Haemoglobin, fluid balance, and opioid use were recorded. Systolic (SAP) and diastolic (DAP) arterial pressure, heart rate (HR), stroke volume (SV), cardiac output (CO...

  2. Indirect Effects of the Fast Track Intervention on Conduct Disorder Symptoms and Callous-Unemotional Traits: Distinct Pathways Involving Discipline and Warmth.

    Science.gov (United States)

    Pasalich, Dave S; Witkiewitz, Katie; McMahon, Robert J; Pinderhughes, Ellen E

    2016-04-01

    Little is known about intervening processes that explain how prevention programs improve particular youth antisocial outcomes. We examined whether parental harsh discipline and warmth in childhood differentially account for Fast Track intervention effects on conduct disorder (CD) symptoms and callous-unemotional (CU) traits in early adolescence. Participants included 891 high-risk kindergarteners (69% male; 51% African American) from urban and rural United States communities who were randomized into either the Fast Track intervention (n = 445) or non-intervention control (n = 446) groups. The 10-year intervention included parent management training and other services (e.g., social skills training, universal classroom curriculum) targeting various risk factors for the development of conduct problems. Harsh discipline (Grades 1 to 3) and warmth (Grades 1 and 2) were measured using parent responses to vignettes and direct observations of parent-child interaction, respectively. Parents reported on children's CD symptoms in Grade 6 and CU traits in Grade 7. Results demonstrated indirect effects of the Fast Track intervention on reducing risk for youth antisocial outcomes. That is, Fast Track was associated with lower scores on harsh discipline, which in turn predicted decreased levels of CD symptoms. In addition, Fast Track was associated with higher scores on warmth, which in turn predicted reduced levels of CU traits. Our findings inform developmental and intervention models of youth antisocial behavior by providing evidence for the differential role of harsh discipline and warmth in accounting for indirect effects of Fast Track on CD symptoms versus CU traits, respectively.

  3. Hardware-based tracking at trigger level for ATLAS: The Fast Tracker (FTK) Project

    CERN Document Server

    Gramling, Johanna; The ATLAS collaboration

    2015-01-01

    Physics collisions at 13 TeV are expected at the LHC with an average of 40-50 proton-proton collisions per bunch crossing. Tracking at trigger level is an essential tool to control the rate in high-pileup conditions while maintaining a good efficiency for relevant physics processes. The Fast TracKer (FTK) is an integral part of the trigger upgrade for the ATLAS detector. For every event passing the Level 1 trigger (at a maximum rate of 100 kHz) the FTK receives data from the 80 million channels of the silicon detectors, providing tracking information to the High Level Trigger in order to ensure a selection robust against pile-up. The FTK performs a hardware-based track reconstruction, using associative memory (AM) that is based on the use of a custom chip, designed to perform pattern matching at very high speed. It finds track candidates at low resolution (roads) that seed a full-resolution track fitting done by FPGAs. Narrow roads permit a fast track fitting but need many patterns stored in the AM to ensure ...

  4. Fast-track, ambulatory ultrasound-guided Tru-Cut liver biopsy is feasible and cost-efficient

    DEFF Research Database (Denmark)

    Huang, Chenxi; Lorentzen, Torben; Skjoldbye, Bjørn

    2015-01-01

    INTRODUCTION: Most institutions perform percutaneous liver biopsy with a post-biopsy patient observation period lasting up to eight hours, which is resource-demanding. This study aimed to evaluate the safety of liver biopsy performed in a fast-track set-up with an only one-hour post......-biopsy observation time. METHODS: Patients referred to our institution underwent fast-track ultrasound-guided 18-gauge Tru-Cut liver biopsy procedures. Each single biopsy procedure was followed by a post-procedure observational period of one hour and an additional focused assessment with sonography for trauma before...... safely discharged from our institution. No fatality or long-term complications were found during this study. CONCLUSION: The fast-track approach reported herein is a feasible option when adequate patient information is given. Besides the obvious, positive effect on patient logistics and departmental...

  5. Comparison of fast neutron-induced tracks in plastics using the electrochemical etching method

    International Nuclear Information System (INIS)

    Cotter, S.J.; Gammage, R.B.; Thorngate, J.H.; Ziemer, P.L.

    1979-01-01

    Four plastics were examined by the electrochemical etching method for their suitability in registering fast neutron-induced recoil particle tracks. The plastics were cellulose acetate, cellulose triacetate, cellulose acetobutyrate and polycarbonate. Cellulose acetate and triacetate displayed high levels of water absorptivity during etching while the acetobutyrate foils cracked due to electromechanical stresses at high frequencies (>500 Hz). The clarity of the etched track was superior in the polycarbonate foils, suggesting the latter as the generally preferred dosimeter for fast neutrons. (author)

  6. A fast track trigger processor for the OPAL detector at LEP

    International Nuclear Information System (INIS)

    Carter, A.A.; Jaroslawski, S.; Wagner, A.

    1986-01-01

    A fast hardware track trigger processor being built for the OPAL experiment is described. The processor will analyse data from the central drift chambers of OPAL to determine whether any tracks come from the interaction region, and thereby eliminate background events. The processor will find tracks over a large angular range, vertical strokecos thetavertical stroke < or approx. 0.95. The design of the processor is described, together with a brief account of its hardware implementation for OPAL. The results of feasibility studies are also presented. (orig.)

  7. The Effects of the Fast Track Preventive Intervention on the Development of Conduct Disorder Across Childhood

    OpenAIRE

    2011-01-01

    The impact of the Fast Track intervention on externalizing disorders across childhood was examined. Eight hundred-ninety-one early-starting children (69% male; 51% African American) were randomly assigned by matched sets of schools to intervention or control conditions. The 10-year intervention addressed parent behavior-management, child social cognitive skills, reading, home visiting, mentoring, and classroom curricula. Outcomes included psychiatric diagnoses after grades 3, 6, 9, and 12 for...

  8. Fast neural-net based fake track rejection in the LHCb reconstruction

    CERN Document Server

    De Cian, Michel; Seyfert, Paul; Stahl, Sascha

    2017-01-01

    A neural-network based algorithm to identify fake tracks in the LHCb pattern recognition is presented. This algorithm, called ghost probability, retains more than 99 % of well reconstructed tracks while reducing the number of fake tracks by 60 %. It is fast enough to fit into the CPU time budget of the software trigger farm and thus reduces the combinatorics of the decay reconstructions, as well as the number of tracks that need to be processed by the particle identification algorithms. As a result, it strongly contributes to the achievement of having the same reconstruction online and offline in the LHCb experiment in Run II of the LHC.

  9. Delirium in fast-track colonic surgery

    DEFF Research Database (Denmark)

    Kurbegovic, Sorel; Andersen, Jens; Krenk, Lene

    2015-01-01

    BACKGROUND: Postoperative delirium (PD) is a common but serious problem after major surgery with a multifactorial pathogenesis including age, pain, opioid use, sleep disturbances and the surgical stress response. These factors have been minimised by the "fast-track methodology" previously...... demonstrated to enhance recovery and reduce morbidity. METHODS: Clinical symptoms of PD were routinely collected three times daily from preoperatively until discharge in a well-defined enhanced recovery program after colonic surgery in 247 consecutive patients. RESULTS: Total median length of hospital stay...... postoperative recovery program may decrease the risk and duration of PD after colonic surgery....

  10. The yield of colorectal cancer among fast track patients with normocytic and microcytic anaemia.

    Science.gov (United States)

    Panagiotopoulou, I G; Fitzrol, D; Parker, R A; Kuzhively, J; Luscombe, N; Wells, A D; Menon, M; Bajwa, F M; Watson, M A

    2014-05-01

    We receive fast track referrals on the basis of iron deficiency anaemia (IDA) for patients with normocytic anaemia or for patients with no iron studies. This study examined the yield of colorectal cancer (CRC) among fast track patients to ascertain whether awaiting confirmation of IDA is necessary prior to performing bowel investigations. A review was undertaken of 321 and 930 consecutive fast track referrals from Centre A and Centre B respectively. Contingency tables were analysed using Fisher's exact test. Logistic regression analyses were performed to investigate significant predictors of CRC. Overall, 229 patients were included from Centre A and 689 from Centre B. The odds ratio for microcytic anaemia versus normocytic anaemia in the outcome of CRC was 1.3 (95% confidence interval [CI]: 0.5-3.9) for Centre A and 1.6 (95% CI: 0.8-3.3) for Centre B. In a logistic regression analysis (Centre B only), no significant difference in CRC rates was seen between microcytic and normocytic anaemia (adjusted odds ratio: 1.9, 95% CI: 0.9-3.9). There was no statistically significant difference in the yield of CRC between microcytic and normocytic anaemia (p=0.515, Fisher's exact test) in patients with anaemia only and no colorectal symptoms. Finally, CRC cases were seen in both microcytic and normocytic groups with or without low ferritin. There is no significant difference in the yield of CRC between fast track patients with microcytic and normocytic anaemia. This study provides insufficient evidence to support awaiting confirmation of IDA in fast track patients with normocytic anaemia prior to requesting bowel investigations.

  11. The ATLAS Fast Tracker and Tracking at the High-Luminosity LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00236423; The ATLAS collaboration

    2016-01-01

    The LHC’s increase in centre of mass energy and luminosity in 2015 makes controlling trigger rates with high efficiency challenging. The ATLAS Fast TracKer (FTK) is a hardware processor built to reconstruct tracks at a rate of up to 100 kHz and provide them to the high level trigger. The FTK reconstructs tracks by matching incoming detector hits with pre-defined track patterns stored in associative memory on custom ASICs. Inner detector hits are fit to these track patterns using modern FPGAs. These procedings describe the electronics system used for the FTK’s massive parallelization. An overview of the installation, commissioning and running of the system is given. The ATLAS upgrades planned to enable tracking at the High Luminosity LHC are also discussed.

  12. Short Hospital Stay after Laparoscopic Colorectal Surgery without Fast Track

    Directory of Open Access Journals (Sweden)

    Stefan K. Burgdorf

    2012-01-01

    Full Text Available Purpose. Short hospital stay and equal or reduced complication rates have been demonstrated after fast track open colonic surgery. However, fast track principles of perioperative care can be difficult to implement and often require increased nursing staff because of more concentrated nursing tasks during the shorter hospital stay. Specific data on nursing requirements after laparoscopic surgery are lacking. The purpose of the study was to evaluate the effect of operative technique (open versus laparoscopic operation, but without changing nurse staffing or principles for peri- or postoperative care, that is, without implementing fast track principles, on length of stay after colorectal resection for cancer. Methods. Records of all patients operated for colorectal cancer from November 2004 to December 2008 in our department were reviewed. No specific patients were selected for laparoscopic repair, which was solely dependent on the presence of two specific surgeons at the same time. Thus, the patients were not selected for laparoscopic repair based on patient-related factors, but only on the simultaneous presence of two specific surgeons on the day of the operation. Results. Of a total of 540 included patients, 213 (39% were operated by a laparoscopic approach. The median hospital stay for patients with a primary anastomosis was significantly shorter after laparoscopic than after conventional open surgery (5 versus 8 days, while there was no difference in patients receiving a stoma (10 versus 10 days, ns, with no changes in the perioperative care regimens. Furthermore there were significant lower blood loss (50 versus 200 mL, and lower complication rate (21% versus 32%, in the laparoscopic group. Conclusion. Implementing laparoscopic colorectal surgery in our department resulted in shorter hospital stay without using fast track principles for peri- and postoperative care in patients not receiving a stoma during the operation. Consequently, we

  13. Clinical evidence of traditional vs fast track recovery methodologies after total arthroplasty for osteoarthritic knee treatment. A retrospective observational study

    Science.gov (United States)

    Castorina, Sergio; Guglielmino, Claudia; Castrogiovanni, Paola; Szychlinska, Marta Anna; Ioppolo, Francesco; Massimino, Paolo; Leonardi, Pietro; Maci, Christian; Iannuzzi, Maurizio; Di Giunta, Angelo; Musumeci, Giuseppe

    2017-01-01

    Summary Background During the last years, programs to enhance postoperative recovery and decrease morbidity after total knee arthroplasty, have been developed across a variety of surgical procedures and referred to as “Fast-Track Surgery”. In this study we aimed to find some answers in the management of osteoarthritic patients subjected to total knee arthroplasty, by using the Fast-Track methodology. To this purpose we evaluated parameters such as early mobilization of patients, better pain management, bleeding, possible complications, reduced hospitalization time, an overall improved recovery and patient satisfaction. Methods 132 patients were selected, of which, 95 treated with “Fast Track” method and 37 treated with traditional method (control group). All the patients were hospitalized and underwent the same rehabilitation program for the first three days after surgery. Results In both groups, the parameters of pain and deformity demonstrated the most rapid improvement, while those of function and movement were normalized as gradual and progressive improvement over the next 2 months. The different functional test used (Barthel, MRC, VAS) showed that the mean values were significantly greater in Fast Track group when compared to the control. Conclusion The results of the study confirm that the application of the Fast Track protocol in orthopaedics after total knee replacement results in rapid post-surgery recovery. Level of evidence IV. Case series, low-quality cohort or case-control studies. PMID:29387645

  14. [Laparoscopic "fast-track" sigmoidectomy for diverticulitis disease in Germany. Results of a prospective quality assurance program].

    Science.gov (United States)

    Tsilimparis, N; Haase, O; Wendling, P; Kipfmüller, K; Schmid, M; Engemann, R; Schwenk, W

    2010-09-01

    The natural course of sigmoid colon diverticulitis during conservative therapy and the assessment of the perioperative morbidity after sigmoid colon resection are differently evaluated by surgeons and gastroenterologists. The "fast-track" rehabilitation accelerates the reconvalescence and reduces the rate of postoperative general complications after colorectal surgery. The results of the laparoscopic "Fast-track" sigmoidectomy should be examined within a quality assurance program to better evaluate the perioperative risks following surgical management of diverticulitis. A prospective data collection within the voluntary quality assurance program "fast-track" Kolon II was performed. All participating clinics agreed on a multimodal, evidence-based standard perioperative treatment in terms of a "fast-track" rehabilitation for elective operations for sigmoid diverticulitis. Data from 846 patients undergoing laparoscopic "fast-track" sigmoid colon resection in 23 surgical departments in Germany were collected and evaluated. The mean age of the patients was 63 years (range 23 - 91). 203 patients (24 %) had severe co-morbidities (ASA classification III - IV). A conversion to conventional open surgery was necessary in 51 cases (6 %). Complications occurred in 93 patients (11 %). 76 patients suffered a surgical complication (8.9 %) and 32 patients (3.8 %) a general complication. Two patients died postoperatively due to multi-organ failure following anastomotic leaks. The patients took solid food in median on day 1 after surgery (range, 0 - 5) and passed stool on day 2 (range, 0 - 22). Predefined discharge criteria (free of pain on oral medication, normal oral feeding, stool) were met on day 4 (range, 1 - 58) and the patients were discharged on day 7 (range, 3 - 72). The 30-day re-admission rate was 3.9 %. Patients undergoing laparoscopic "fast-track" sigmoidectomy had a low rate of general complications and had a rapid reconvalescence with a short postoperative in

  15. Laparoscopic surgery contributes more to nutritional and immunologic recovery than fast-track care in colorectal cancer.

    Science.gov (United States)

    Xu, Dong; Li, Jun; Song, Yongmao; Zhou, Jiaojiao; Sun, Fangfang; Wang, Jianwei; Duan, Yin; Hu, Yeting; Liu, Yue; Wang, Xiaochen; Sun, Lifeng; Wu, Linshan; Ding, Kefeng

    2015-02-04

    Many clinical trials had repeatedly shown that fast-track perioperative care and laparoscopic surgery are both preferred in the treatment of colorectal cancer. But few studies were designed to explore the diverse biochemical impacts of the two counterparts on human immunologic and nutritional status. Ninety-two cases of colorectal cancer patients meeting the inclusion criteria were randomized to four groups: laparoscopy with fast-track treatment (LAFT); open surgery with fast-track treatment (OSFT); laparoscopy with conventional treatment (LAC); open surgery with conventional treatment (OSC). Peripheral blood tests including nutritional factors (albumin, prealbumin, and transferrin), humoral immunologic factors (IgG, IgM, and IgA), and cellular immunologic factors (T and NK cells) were evaluated. Blood samples were collected preoperatively (baseline) and 12 and 96 h after surgery (indicated as POH12 and POH96, respectively). Albumin, transferrin, prealbumin, and IgG levels were the highest in the LAFT group for both POH12 and POH96 time intervals. Repeated measures (two-way ANOVA) indicated that the difference of albumin, transferrin, and IgG level were attributed to surgery type (P  0.05). Only in the laparoscopy-included groups, the relative albumin and IgG levels of POH96 were obviously higher than that of POH12. Laparoscopic surgery accelerated postoperative nutrition and immune levels rising again while fast-track treatment retarded the drop of postoperative nutrition and immune levels. Laparoscopic surgery might play a more important role than fast-track treatment in the earlier postoperative recovery of nutritional and immunologic status. Combined laparoscopic surgery with fast-track treatment provided best postoperative recovery of nutrition and immune status. These results should be further compared with the clinical outcomes of our FTMDT trial (clinicaltrials.gov: NCT01080547).

  16. Fast Track Open Partial Nephrectomy: Reduced Postoperative Length of Stay with a Goal-Directed Pathway Does Not Compromise Outcome

    Directory of Open Access Journals (Sweden)

    Bilal Chughtai

    2008-01-01

    Full Text Available Introduction. The aim of this study is to examine the feasibility of reducing postoperative hospital stay following open partial nephrectomy through the implementation of a goal directed clinical management pathway. Materials and Methods. A fast track clinical pathway for open partial nephrectomy was introduced in July 2006 at our institution. The pathway has daily goals and targets discharge for all patients on the 3rd postoperative day (POD. Defined goals are (1 ambulation and liquid diet on the evening of the operative day; (2 out of bed (OOB at least 4 times on POD 1; (3 removal of Foley catheter on the morning of POD 2; (4 removal of Jackson Pratt drain on the afternoon of POD 2; (4 discharge to home on POD 3. Patients and family are instructed in the fast track protocol preoperatively. Demographic data, tumor size, length of stay, and complications were captured in a prospective database, and compared to a control group managed consecutively immediately preceding the institution of the fast track clinical pathway. Results. Data on 33 consecutive patients managed on the fast track clinical pathway was compared to that of 25 control patients. Twenty two (61% out of 36 fast track patients and 4 (16% out of 25 control patients achieved discharge on POD 3. Overall, fast track patients had a shorter hospital stay than controls (median, 3 versus 4 days; P = .012. Age (median, 55 versus 57 years, tumor size (median, 2.5 versus 2.5 cm, readmission within 30 days (5.5% versus 5.1%, and complications (10.2% versus 13.8% were similar in the fast track patients and control, respectively. Conclusions. In the present series, a fast track clinical pathway after open partial nephrectomy reduced the postoperative length of hospital stay and did not appear to increase the postoperative complication rate.

  17. Hardware-based Tracking at Trigger Level for ATLAS: The Fast TracKer (FTK) Project

    CERN Document Server

    Gramling, Johanna; The ATLAS collaboration

    2015-01-01

    Physics collisions at 13 TeV are expected at the LHC with an average of 40-50 proton-proton collisions per bunch crossing. Tracking at trigger level is an essential tool to control the rate in high-pileup conditions while maintaining a good efficiency for relevant physics processes. The Fast TracKer (FTK) is an integral part of the trigger upgrade for the ATLAS detector. For every event passing the Level 1 trigger (at a maximum rate of 100 kHz) the FTK receives data from the 80 million channels of the silicon detectors, providing tracking information to the High Level Trigger in order to ensure a selection robust against pile-up. The FTK performs a hardware- based track reconstruction, using associative memory (AM) that is based on the use of a custom chip, designed to perform pattern matching at very high speed. It finds track candidates at low resolution (roads) that seed a full-resolution track fitting done by FPGAs. Narrow roads permit a fast track fitting but need many patterns stored in the AM to ensure...

  18. Research on Precision Tracking on Fast Steering Mirror and Control Strategy

    Science.gov (United States)

    Di, Lin; Yi-ming, Wu; Fan, Zhu

    2018-01-01

    Fast steering mirror is a device used for controlling the beam direction precisely. Due to the short travel of the push-pull FSM, a compound fast steering mirror system driven by both limited-angle voice coil motor and push-pull FSM together is proposed. In the compound FSM system, limited-angle voice coil motor quickly swings at wide angle, while the push-pull FSM do high frequency movement in a small range, which provides the system with the high bandwidth and long travel. In the control strategy, the method of combining feed-forward control in Kalman filtering with auto-disturbance rejection control is used to improve trajectory tracking accuracy. The simulation result shows that tracking accuracy measured by the compound method can be improved by more than 5 times than that of the conventional PID.

  19. Patient-reported outcome after fast-track hip arthroplasty: a prospective cohort study

    Directory of Open Access Journals (Sweden)

    Hansen Torben B

    2010-11-01

    Full Text Available Abstract Background A fast-track intervention with a short preoperative optimization period and short postoperative hospitalization has a potential for reduced convalescence and thereby a reduced need for postoperative rehabilitation. The purpose of this study was to describe patient-related outcomes, the need for additional rehabilitation after a fast-track total hip arthroplasty (THA, and the association between generic and disease specific outcomes. Methods The study consisted of 196 consecutive patients of which none received additional rehabilitation beyond an instructional exercise plan at discharge, which was adjusted at one in-patient visit. The patients filled in 3 questionnaires to measure health-related quality-of-life (HRQOL and hip specific function (EQ-5 D, SF36, and Harris Hip Score (HHS at 2 time points pre- and 2 time points postoperatively. The observed results were compared to normative population data for EQ-5 D, SF36, and HHS. Results 3-months postoperatively patients had reached a HRQOL level of 0.84 (SD, 0.14, which was similar to the population norm (P = 0.33, whereas they exceeded the population norm at 12 months postoperatively (P P P = 0.35. For HHS, patients never reached the population norm within 12 months postoperatively. Generic and disease specific outcomes were strongly associated. Conclusions If HRQOL is considered the primary outcome after THA, the need for additional postoperative rehabilitation for all THA patients following a fast-track intervention is questionable. However, a pre- or early postoperative physical intervention seems relevant if the PF of the population norm should be reached at 3 months. If disease specific outcome is considered the primary outcome after fast-track THA, clear goals for the rehabilitation must be established before patient selection, intervention type and timing of intervention can be made.

  20. FAST: A fully asynchronous and status-tracking pattern for geoprocessing services orchestration

    Science.gov (United States)

    Wu, Huayi; You, Lan; Gui, Zhipeng; Gao, Shuang; Li, Zhenqiang; Yu, Jingmin

    2014-09-01

    Geoprocessing service orchestration (GSO) provides a unified and flexible way to implement cross-application, long-lived, and multi-step geoprocessing service workflows by coordinating geoprocessing services collaboratively. Usually, geoprocessing services and geoprocessing service workflows are data and/or computing intensive. The intensity feature may make the execution process of a workflow time-consuming. Since it initials an execution request without blocking other interactions on the client side, an asynchronous mechanism is especially appropriate for GSO workflows. Many critical problems remain to be solved in existing asynchronous patterns for GSO including difficulties in improving performance, status tracking, and clarifying the workflow structure. These problems are a challenge when orchestrating performance efficiency, making statuses instantly available, and constructing clearly structured GSO workflows. A Fully Asynchronous and Status-Tracking (FAST) pattern that adopts asynchronous interactions throughout the whole communication tier of a workflow is proposed for GSO. The proposed FAST pattern includes a mechanism that actively pushes the latest status to clients instantly and economically. An independent proxy was designed to isolate the status tracking logic from the geoprocessing business logic, which assists the formation of a clear GSO workflow structure. A workflow was implemented in the FAST pattern to simulate the flooding process in the Poyang Lake region. Experimental results show that the proposed FAST pattern can efficiently tackle data/computing intensive geoprocessing tasks. The performance of all collaborative partners was improved due to the asynchronous mechanism throughout communication tier. A status-tracking mechanism helps users retrieve the latest running status of a GSO workflow in an efficient and instant way. The clear structure of the GSO workflow lowers the barriers for geospatial domain experts and model designers to

  1. Fast neutron dosimetry using CR-39 track detectors with polyethylene as radiator

    International Nuclear Information System (INIS)

    Castillo, F.; Espinosa, G.; Golzarri, J.I.; Osorio, D.; Rangel, J.; Reyes, P.G.; Herrera, J.J.E.

    2013-01-01

    The chemical etching parameters (etching time, temperature, normality of etchant, etc.) for the use of CR-39 (allyl diglycol carbonate – Lantrack ® ) as a fast neutron dosimeter have been optimized. The CR-39 chips, placed under a 1.5 mm polyethylene radiator, were exposed for calibration to an 241 Am-Be source at different time intervals for a given neutron fluence. After several chemical etching processes of the detectors with different conditions, the optimum characteristics for the chemical etching were found at 6N KOH solution, 60 ± 1 °C, for 12 h. An accurate relationship between the dose and fluence calculations was obtained as a function of the track density. - Highlights: ► Optimum etching time for fast neutron irradiated CR-39 track detectors is found. ► Relationship between dose and fluence obtained as a function of the track density. ► Results are consistent with those reported elsewhere, and extend the dose range

  2. Avoiding ICU Admission by Using a Fast-Track Protocol Is Safe in Selected Adult-to-Adult Live Donor Liver Transplant Recipients

    Directory of Open Access Journals (Sweden)

    Juan Echeverri, MD

    2017-10-01

    Full Text Available Background. We evaluated patient characteristics of live donor liver transplant (LDLT recipients undergoing a fast-track protocol without intensive care unit (ICU admission versus LDLT patients receiving posttransplant ICU care. Methods. Of the 153 LDLT recipients, 46 patients were included in our fast-track protocol without ICU admission. Both, fast-tracked patients and ICU-admitted patients were compared regarding donor and patient characteristics, perioperative characteristics, and postoperative outcomes and complications. In a subgroup analysis, we compared fast-tracked patients with patients who were admitted in the ICU for less than 24 hours. Results. Fast-tracked versus ICU patients had a lower model for end-stage liver disease score (13 ± 4 vs 18 ± 7; P < 0.0001, lower preoperative bilirubin levels (51 ± 50 μmol/L vs 119.4 ± 137.3 μmol/L; P < 0.001, required fewer units of packed red blood cells (1.7 ± 1.78 vs 4.4 ± 4; P < 0.0001, and less fresh-frozen plasma (2.7 ± 2 vs 5.8 ± 5; P < 0.0001 during transplantation. Regarding postoperative outcomes, fast-tracked patients presented fewer bacterial infections within 30 days (6.5% [3] vs 29% [28]; P = 0.002, no episodes of pneumonia (0% vs 11.3% [11]; P = 0.02, and less biliary complications within the first year (6% [3] vs 26% [25]; P = 0.001. Also, fast-tracked patients had a shorter posttransplant hospital stay (10.8 ± 5 vs 21.3 ± 29; P = 0.002. In the subgroup analysis, fast-tracked vs ICU patients admitted for less than 24 hours had lower requirements of packed red blood cells (1.7 ± 1.78 vs 3.9 ± 4; P = 0.001 and fresh-frozen plasma (2.7 ± 2 vs 5.8 ± 4.5; P = 0.0001. Conclusions. Fast-track of selected patients after LDLT is safe and feasible. An objective score to perioperatively select LDLT recipients amenable to fast track is yet to be determined.

  3. Readmissions after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Kristian Stahl; Kristensen, Billy B

    2010-01-01

    With the implementation of fast-track surgery with optimization of both logistical and clinical features, the postoperative convalescence has been reduced as functional milestones have been achieved earlier and consequently length of stay (LOS) in hospital has been reduced. However, it has been s...... speculated that a decrease in LOS may be associated with an increase in readmissions in general, including risk of dislocation after total hip arthroplasty (THA) or manipulation after total knee arthroplasty (TKA)....

  4. [Shortened hospital stay for elective cesarean section after initiation of a fast-track program and midwifery home-care].

    Science.gov (United States)

    Gunnarsdottir, Johanna; Bjornsdottir, Thorbjörg Edda; Halldorsson, Thorhallur Ingi; Halldorsdottir, Gudrun; Geirsson, Reynir Tomas

    2011-07-01

    To audit whether hospital stay shortened without increasing readmissions after implementation of fast-track methodology for elective cesarean section and characterize what influences length of stay. A fast-track program was initiated in November 2008, with a one year clinical audit and satisfaction survey. Discharge criteria were predefined and midwife home visits included if discharge was within 48 hours. Hospital stay by parity for women with elective section for singleton pregnancy between 1.11. 2008 - 31.10. 2009 (n=213, fast-track 182) was compared to 2003 (n=199) and 2007 (n=183). Readmissions and outpatient visits 2007 and 2008-9 were counted. Reasons for longer stay were recorded in fast-track, and body mass index. Median hospital stay decreased significantly from 81 to 52 hours between 2007 and 2008-9. Readmissions were four in each period and outpatient visit rates similar. In 2008-9, 66% of all women were discharged within 48 hours. Women in the fast-track program were satisfied with early discharge. Hospital stay for parous women was shorter in 2007 compared to 2003, but unchanged for nulliparas. Parity had a minimal influence on length of stay in 2008-9, although nulliparous women ≤ 25 years were more likely to stay >48 hours. Body mass index did not correlate with length of stay. Pain was rarely the reason for a longer stay in the fast-track program and 90% were satisfied with pain-medication after discharge. Most healthy women can be discharged early after singleton birth by elective cesarean, without increasing readmissions.

  5. Subacute pain and function after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Lasse Østergaard; Gaarn-Larsen, L; Kristensen, B B

    2009-01-01

    In a well-defined fast-track setup for total hip and knee arthroplasty, with a multimodal analgesic regimen consisting of intra-operative local anaesthetic infiltration and oral celecoxib, gabapentin and paracetamol for 6 days postoperatively, we conducted a prospective, consecutive, observationa...

  6. Fast track multi-discipline treatment (FTMDT trial versus conventional treatment in colorectal cancer--the design of a prospective randomized controlled study

    Directory of Open Access Journals (Sweden)

    Zhou Jiao-Jiao

    2011-11-01

    Full Text Available Abstract Background Laparoscopy-assisted surgery, fast-track perioperative treatment are both increasingly used in colorectal cancer treatment, for their short-time benefits of enhanced recovery and short hospital stays. However, the benefits of the integration of the Laparoscopy-assisted surgery, fast-track perioperative treatment, and even with the Xelox chemotherapy, are still unknown. In this study, the three treatments integration is defined as "Fast Track Multi-Discipline Treatment Model" for colorectal cancer and this model extends the benefits to the whole treatment process of colorectal cancer. The main purpose of the study is to explore the feasibility of "Fast Track Multi-Discipline Treatment" model in treatment of colorectal cancer. Methods The trial is a prospective randomized controlled study with 2 × 2 balanced factorial design. Patients eligible for the study will be randomized to 4 groups: (I Laparoscopic surgery with fast track perioperative treatment and Xelox chemotherapy; (II Open surgery with fast track perioperative treatment and Xelox chemotherapy; (III Laparoscopic surgery with conventional perioperative treatment and mFolfox6 chemotherapy; (IV Open surgery with conventional perioperative treatment and mFolfox6 chemotherapy. The primary endpoint of this study is the hospital stays. The secondary endpoints are the quality of life, chemotherapy related adverse events, surgical complications and hospitalization costs. Totally, 340 patients will be enrolled with 85 patients in each group. Conclusions The study initiates a new treatment model "Fast Track Multi-Discipline Treatment" for colorectal cancer, and will provide feasibility evidence on the new model "Fast Track Multi-Discipline Treatment" for patients with colorectal cancer. Trial registration ClinicalTrials.gov: NCT01080547

  7. Fast-track remediation case study: Southern California refined fuel distributor

    International Nuclear Information System (INIS)

    Bubier, T.W.; Felix, P.R.

    1993-01-01

    Successful environmental remediation projects have three requirements in common: (1) an adequate data base that defines the extent and severity of the problem; (2) a detailed understanding of the actual performance of the remediation technologies being considered; and (3) good communication with the regulatory agencies to assure them that the health and safety of the community and workers will not be jeopardized. In a fast-track remediation project, these requirements are key issues in the critical path. The case study involves soil and groundwater remediation of a 16-acre bulk fuel storage and distribution facility. The facility was in operation for approximately 75 years and contained 20 large aboveground tanks with a total capacity in excess of 20 million gallons. Activities at the facility included receipt, storage, and distribution of refined fuel products, such as kerosene, gasoline, diesel, and bunker fuel. A harbor-widening project was undertaken to increase the level of safety for larger ships when passing through the port. Because of the critical need for harbor-widening, the environmental cleanup needed to be completed as quickly as possible. The following steps were taken during the fast-track remediation case study to meet the above-listed requirements: (1) New Data Quality Objectives (DQOs) were identified for the project; (2) Potentially applicable remedial technologies were evaluated and tested; and (3) An agency task force was developed to enhance communication with the regulatory agencies. This paper discusses these steps and presents examples of how each step was implemented during the remediation case study

  8. Maintaining Unity - relatives in older patients' fast-track treatment programmes. A grounded theory study.

    Science.gov (United States)

    Berthelsen, Connie Bøttcher; Lindhardt, Tove; Frederiksen, Kirsten

    2014-12-01

    To generate a substantive grounded theory of relatives' pattern of behaviour in older patients' fast-track treatment programmes during total hip or knee replacement. Fast-track treatment programmes are designed to make total hip and knee replacements more efficient through recovery improvements. The support of relatives during older patients' trajectory is important. However, knowledge is needed on the relatives' pattern of behaviour to strengthen their involvement in fast-track treatment programmes. We used a Glaserian grounded theory approach based on a systematic generation of theory from data to explain the latent pattern of behaviour of relatives. Data were collected from 2010-2011 in orthopaedic wards at two Danish university hospitals and consisted of 14 non-participant observations, 14 postobservational interviews and five interviews. Seven relatives of patients over 70 years of age participated. The constant comparative method was the guiding principle for simultaneous data collection, data analysis and coding, while theoretically sampling and writing memos. Maintaining Unity emerged as the relatives' pattern of behaviour through which they resolved their main concern: preventing the patients from feeling alone. The relatives resolved their main concern through three interchangeable behavioural modes: Protecting Mode, by providing loving and respectful support; Substituting Mode, with practical and cognitive support; and an Adapting Mode, by trying to fit in with the patients' and health professionals' requirements. The substantive theory of Maintaining Unity offers knowledge of relatives' strong desire to provide compassionate and loving support for the older patients during fast-track treatment programmes. © 2014 John Wiley & Sons Ltd.

  9. Serious renal and urological complications in fast-track primary total hip and knee arthroplasty; a detailed observational cohort study

    DEFF Research Database (Denmark)

    Bjerregaard, Lars S; Jorgensen, Christoffer C; Kehlet, Henrik

    2016-01-01

    of stay > 4 days or 30-day readmissions after fast-track THA and TKA, we conducted a detailed observational study based upon prospectively collected pre-operative data and a complete 30-day follow-up on complications and re-admissions in a unselected cohort of 8,804 consecutive fast-track THAs and TKAs......BACKGROUND: Overall medical complications have been reduced after fast-track total hip (THA) and knee arthroplasty (TKA), but data on specific renal and urological (RU) complications are limited. METHODS: To describe the incidence and consequences of serious RU complications resulting in length...

  10. When is it optimal to delegate: the theory of fast-track authority

    Czech Academy of Sciences Publication Activity Database

    Celik, Levent; Karabay, B.; McLaren, J.

    2015-01-01

    Roč. 7, č. 3 (2015), s. 347-389 ISSN 1945-7669 Institutional support: RVO:67985998 Keywords : fast-track authority * free trade * protectionist rents Subject RIV: AH - Economics Impact factor: 1.359, year: 2015

  11. Role of patient characteristics for fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, C.; Jacobsen, M; Søballe, Kjeld

    2013-01-01

    BACKGROUND: /st>Patient age and comorbidity have been found to increase the length of hospital stay (LOS), readmissions, and mortality after surgery, including in elective primary total hip arthroplasty (THA) and total knee arthroplasty (TKA). Whether the same applies in fast-track THA and TKA...

  12. Fast track surgery at the University Teaching Hospital of Kigali: a ...

    African Journals Online (AJOL)

    Background: Fast Track Surgery is synonymous with Enhanced Recovery after Surgery. It was started in the 1990's initially for colorectal surgery, but later became applicable to other aspects of surgery. Its core elements include epidural or regional anaesthesia, perioperative fluid management, minimally invasive surgical ...

  13. Automatic detection of recoil-proton tracks and background rejection criteria in liquid scintillator-micro-capillary-array fast neutron spectrometer

    Science.gov (United States)

    Mor, Ilan; Vartsky, David; Dangendorf, Volker; Tittelmeier, Kai.; Weierganz, Mathias; Goldberg, Mark Benjamin; Bar, Doron; Brandis, Michal

    2018-06-01

    We describe an analysis procedure for automatic unambiguous detection of fast-neutron-induced recoil proton tracks in a micro-capillary array filled with organic liquid scintillator. The detector is viewed by an intensified CCD camera. This imaging neutron detector possesses the capability to perform high position-resolution (few tens of μm), energy-dispersive transmission-imaging using ns-pulsed beams. However, when operated with CW or DC beams, it also features medium-quality spectroscopic capabilities for incident neutrons in the energy range 2-20 MeV. In addition to the recoil proton events which display a continuous extended track structure, the raw images exhibit complex ion-tracks from nuclear interactions of fast-neutrons in the scintillator, capillaries quartz-matrix and CCD. Moreover, as expected, one also observes a multitude of isolated scintillation spots of varying intensity (henceforth denoted "blobs") that originate from several different sources, such as: fragmented proton tracks, gamma-rays, heavy-ion reactions as well as events and noise that occur in the image-intensifier and CCD. In order to identify the continuous-track recoil proton events and distinguish them from all these background events, a rapid, computerized and automatic track-recognition-procedure was developed. Based on an appropriately weighted analysis of track parameters such as: length, width, area and overall light intensity, the method is capable of distinguishing a single continuous-track recoil proton from typically surrounding several thousands of background events that are found in each CCD frame.

  14. LiTrack A Fast longitudinal phase space tracking code with graphical user interface

    CERN Document Server

    Emma, Paul

    2005-01-01

    Many linear accelerators, such as linac-based light sources and linear colliders, apply longitudinal phase space manipulations in their design, including electron bunch compression and wakefield-induced energy spread control. Several computer codes handle such issues, but most require detailed information on the transverse focusing lattice. In fact, in most linear accelerators, the transverse distributions do not significantly affect the longitudinal, and can be ignored initially. This allows the use of a fast 2D code to study longitudinal aspects without time-consuming considerations of the transverse focusing. LiTrack is based on a 15-year old code (same name) originally written by one of us (KB), which is now a MATLAB-based code with additional features, such as a graphical user interface and output plotting. The single-bunch tracking includes RF acceleration, bunch compression to 3rd order, geometric and resistive wakefields, aperture limits, synchrotron radiation, and flexible output plotting. The code w...

  15. [Effects of a nutritional intervention in a fast-track program for a colorectal cancer surgery: systematic review].

    Science.gov (United States)

    Wanden-Berghe, Carmina; Sanz-Valero, Javier; Arroyo-Sebastián, Antonio; Cheikh-Moussa, Kamila; Moya-Forcen, Pedro

    2016-07-19

    Introducción: Preoperative nutritional status (NS) has consequences on postoperative (POSTOP) recovery. Our aim was to systematically review the nutritional interventions (NI) in Fast-Track protocols for colorectal cancer surgery and assess morbidity-mortality and patient´s recovery. Systematic review of scientific literature after consulting bibliographic databases: Medline, The Cochrane Library, Scopus, Embase, Web of Science, Institute for Scientific Information, Latin American and Caribbean Health Sciences Literature, The Cumulative Index to Nursing and Allied Health Literature. MeSH Descriptors: "Colorectal Surgery", "Fast-Track", "Perioperative Care", "Nutrition Therapy" and "Enhanced recovery programme". Filters: "Humans", Adult (19+ years) and "Clinical Trial". Variables POSTOP outcomes: bowel recovery (BR), hospital stay (HS), complications and death. Selected studies, 27, had good or excellent methodological quality. From 25 to 597 patients were included. Aged between 16-94 years, men were predominant in 66.6%. NS was evaluated in 13 studies; 7 by Body Mass Index while one by Subjective Global Assessment. One presented POSTOP data. Fast-Track groups had solids, liquids or supplements (SS) in prior 2-8 hours. SS were high in carbohydrates, immune-nutrients and non-residue. Free liquids, solids and SS intake was allowed in POSTOP. Half traditional groups fasted between 3-12 hours and resumed POSTOP food intake progressively. Fast-Track groups had early BR (p Nutritional status must be assessed for a higher acknowledgement of NI impact.

  16. Fast Track Extubation In Adult Patients On Pump Open Heart Surgery At A Tertiary Care Hospital.

    Science.gov (United States)

    Akhtar, Mohammad Irfan; Sharif, Hasanat; Hamid, Mohammad; Samad, Khalid; Khan, Fazal Hameed

    2016-01-01

    Fast-track cardiac surgery programs have been established as the standard of cardiac surgical care. Studies have shown that early extubation in elective cardiac surgery patients, including coronary and non-coronary open-heart surgery patients does not increase perioperative morbidity and mortality. The objective of this observational study was to determine the success and failure profile of fast track extubation (FTE) practice in adult open-heart surgical patients. The study was conducted at cardiac operating room and Cardiac Intensive Care Unit (CICU) of a tertiary care hospital for a period of nine months, i.e., from Oct 2014 to June-2015. All on pump elective adult cardiac surgery patients including isolated CABG, isolated Valve replacements, combined procedures and aortic root replacements were enrolled in the study. Standardized anesthetic technique was adopted. Surgical and bypass techniques were tailored according to the procedure. Success of Fast track extubation was defined as extubation within 6 hours of arrival in CICU. A total of 290 patients were recruited. The average age of the patients was 56.3±10.5 years. There were 77.6% male and 22.4% female patients. Overall success rate was 51.9% and failure rate was 48.1%. The peri-operative renal insufficiency, cross clamp time and CICU stay (hours) were significantly lower in success group. Re-intubation rate was 0.74%. The perioperative parameters were significantly better in success group and the safety was also demonstrated in the patients who were fast tracked successfully. To implement the practice in its full capacity and benefit, a fast track protocol needs to be devised to standardize the current practices and to disseminate the strategy among junior anaesthesiologists, perfusionists and nursing staff.

  17. Implementing large scale fast track diagnostics in a comprehensive cancer center, pre- and post-measurement data.

    Science.gov (United States)

    van Harten, W H; Goedbloed, N; Boekhout, A H; Heintzbergen, S

    2018-02-07

    In general, patients with a cancer suspicion visit the hospital multiple times before diagnosis is completed. Using various "operations management" techniques a few fast track diagnostic services were implemented in the Netherlands Cancer Institute (NKI) in 2006. Growing patient numbers and increasing process complexity, led to diminished service levels. To decrease the amount of patient visits and to extend these services beyond the (obvious) breast cancer services, fast track diagnostics is now implemented for all 18 cancer types that present with a frequency of minimally one per week. The throughput time (first visit to diagnosis conversation) was measured before, and after implementation of fast track diagnostics. The process was redesigned closely involving the multidisciplinary teams. In an eclectic approach elements from lean management, theory of constraints and mathematical analysis were used to organize slots per tumor type for MRI, CT, PET and echography. A post measurement was performed after 3 and 6 months. In pre measurement access time was calculated to be 10 to 15 workdays, mean throughput time was 6.0 workdays. It proved possible to design the process of 18 tumors as a fast track, of which 7 as "one stop shop" (diagnosis completed in one visit). Involvement of clinical- and board leadership, massive communication efforts and commitment of physicians to reschedule their work proved decisive. After 3 and 6 months of implementation, the mean access time was 8.2 and 8.7 workdays respectively and mean throughput time was 3.4 and 3.3 workdays respectively. Throughput- and access time were considerably shortened after implementation of fast track diagnostics for 18 cancer types. The involvement of physicians in reorganizing their work and rapid responding to their needs during the implementation phase were a crucial success factor.

  18. Fast track diagnosis as a means of reducing diagnostic delay in cancer

    DEFF Research Database (Denmark)

    Larsen, Mette Bach; Vedsted, Peter; Olesen, Frede

    of cancer and expanded services to the general practitioners. Objective: To investigate the diagnostic delay of cancer, patient and provider satisfaction and health economic aspects in two Danish regions with special emphasis on the possible benefits of fast track diagnosis. Methods: The study......Background: Denmark has the highest morbidity and mortality from cancer in Western Europe, and studies suggest that Danish cancer patients are diagnosed at a later stage than patients in the other Nordic countries. To address this issue a Danish hospital has introduced fast track diagnosis...... will be designed as a cross-sectional study with the construction of a clinical database of all incident cancers in two Danish regions within a year (12,000 patients). Data will be collected from general practitioners, patients and national registers. In the first part of the analysis the general variation...

  19. Fast-track surgery: A new concept of perioperative management of surgical patients

    Directory of Open Access Journals (Sweden)

    Gabriel Rodrigues

    2013-01-01

    Full Text Available In the past few decades, surgery has advanced greatly because of an improved understanding of perioperative pathophysiology, development of minimally invasive operative techniques and advanced anaesthetic techniques. Fewer operations are requiring extended periods of hospital stay and a growing number of procedures are performed on an ambulatory basis. The pressure on medical systems is continuously growing as a result of economic constraints, increasing numbers of patients undergoing surgical procedures and greater patient autonomy. Patient awareness is steadily increasing along with their participation in their own care, leading to expectations of a higher standard of care. This has led to the development of a new concept of fast-track surgery.

  20. Effect of fast-track cardiac anesthesia on myocardial oxidative damage, inflammation and nerve related peptides of patients undergoing cardiac operation

    Directory of Open Access Journals (Sweden)

    Xing-Tao Cai

    2016-01-01

    Full Text Available Objective: To study the effect of fast-track cardiac anesthesia on myocardial oxidative damage, inflammation and nerve related peptides of patients undergoing cardiac operation. Methods: Sixty patients with rheumatic heart disease undergoing heart valve surgery were randomly divided into the fast track group (n=30 and conventional group (n=30. Then myocardial injury indicators, mitochondrial oxidative stress indicators, inflammation indicators and nerverelated peptides of both groups were analyzed. Results: cTnI contents at T2-T4 points in time of both groups showed an increasing trend and the increasing trend of fast track group was weaker than that of conventional group; SOD contents as well as mitochondrial tristate respiratory function, respiratory control ratios and phosphorus oxygen ratios in myocardial tissue of fast track group were higher than those of conventional group, and MDA contents was lower than those of conventional group; plasma TNF-α, IL-6, IL-8, NSE, S100β and Aβ contents of fast track group were lower than those of conventional group. Conclusions: Fasttrack cardiac anesthesia can protect myocardial cells, reduce mitochondrial oxidative stress, relieve inflammation and improve nerve function; it is an ideal anesthesia method for cardiac operation.

  1. A fast track path improves access to palliative care for people with learning disabilities.

    Science.gov (United States)

    Whitington, Jane; Ma, Peng

    People with learning disabilities often experience inequalities in accessing general health services. This group, their families and carers need access to effective palliative care when facing a life limiting illness. This article describes the development and implementation of a fast track referral pathway for people with learning disabilities at St Francis Hospice in Essex. Our aim is to share this pathway so others can replicate the collaborative working to improve access to palliative care services for this group.

  2. A Fast Track approach to deal with the temporal dimension of crop water footprint

    Science.gov (United States)

    Tuninetti, Marta; Tamea, Stefania; Laio, Francesco; Ridolfi, Luca

    2017-07-01

    Population growth, socio-economic development and climate changes are placing increasing pressure on water resources. Crop water footprint is a key indicator in the quantification of such pressure. It is determined by crop evapotranspiration and crop yield, which can be highly variable in space and time. While the spatial variability of crop water footprint has been the objective of several investigations, the temporal variability remains poorly studied. In particular, some studies approached this issue by associating the time variability of crop water footprint only to yield changes, while considering evapotranspiration patterns as marginal. Validation of this Fast Track approach has yet to be provided. In this Letter we demonstrate its feasibility through a comprehensive validation, an assessment of its uncertainty, and an example of application. Our results show that the water footprint changes are mainly driven by yield trends, while evapotranspiration plays a minor role. The error due to considering constant evapotranspiration is three times smaller than the uncertainty of the model used to compute the crop water footprint. These results confirm the suitability of the Fast Track approach and enable a simple, yet appropriate, evaluation of time-varying crop water footprint.

  3. Thigh and knee circumference, knee-extension strength, and functional performance after fast-track total hip arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten Tange; Husted, Henrik

    2011-01-01

    OBJECTIVE: To (1) quantify changes in knee-extension strength and functional-performance at discharge after fast-track total hip arthroplasty (THA) and (2) investigate whether these changes correlate to changes in thigh and knee circumference (ie, swelling) or pain. DESIGN: A prospective, descrip......OBJECTIVE: To (1) quantify changes in knee-extension strength and functional-performance at discharge after fast-track total hip arthroplasty (THA) and (2) investigate whether these changes correlate to changes in thigh and knee circumference (ie, swelling) or pain. DESIGN: A prospective......, descriptive, hypothesis-generating study. SETTING: A special unit for fast-track hip and knee arthroplasty operations at a university hospital. PARTICIPANTS: Twenty-four patients (20 women and 4 men; ages 69 ± 6.1 years) scheduled for primary unilateral THA. METHODS: All patients were evaluated before surgery......, except for hip pain. The average loss in knee-extension strength after surgery (32%, P = .01) did not correlate with increased thigh circumference (6%, P

  4. Anesthetic and adjunctive drugs for fast-track surgery.

    Science.gov (United States)

    Baldini, G; Carli, F

    2009-08-01

    With the changes in health care dictated by economic pressure, there has been a realization that hospital stay could be shortened without compromising quality of care. Advances in surgical technology and anesthetic drugs have made an impact in the way perioperative care is delivered with some emphasis on multidisciplinary approach. From the expansion of ambulatory care, lessons were learnt how to apply same concepts to major surgery with the understanding that interventions to attenuate the surgical stress would facilitate the return to "baseline". Beside minimal invasive approach to surgery, anesthesia interventions are arranged with the intent to decrease the negative effects of surgical stress and pain, to minimize the side effects of drugs and at the same time to facilitate the recuperation which follows after surgery. Fast-track or accelerated care encompasses many aspects of anesthesia care, not only preoperative preparation and prehabilitation, but intraoperative attenuation of surgical stress and postoperative rehabilitation. The anesthesiologist is part of this team with the specific mission to use medications and techniques which have the least side effects on organ functions, provide analgesia which in turn facilitates the intake of food and mobilization out of bed. This chapter has been conceived with the intention to direct the clinician towards procedure-specific protocols where the choice of medications and techniques is based on published evidence. The success of implementing fast-track depends more on dynamic harmony amongst the various participants (surgeons, anesthesiologists, nurses, nutrtionists, physiotherapists) than on reaching an optimum level of excellence at each separate organization level.

  5. Fast Tracker (FTK): A Hardware Track Finder for the ATLAS Trigger

    CERN Document Server

    Mitani, Takashi; The ATLAS collaboration

    2015-01-01

    During the 2010-2012 run of Large Hadron Collider experiment, the ATLAS trigger system was successfully operated and it contributed to several important results such as observation of Higgs boson with a mass of about 125 GeV. From 2015, collision energy will increase to 13-14 TeV and its instantaneous luminosity will reach $1$-$2\\times10^{34}$cm$^{-2}$s$^{-1}$ with a 25 ns bunch crossing period. Due to the energy increase, the cross sections for SM processes are expected to get much larger. Additionally, the number of overlapping proton-proton interactions per bunch crossing, which is refereed to as pile-up, is expected to increase significantly up to about 80. Therefore it will be challenging to control trigger rates while keeping good efficiency for interesting physics events. This document summarizes the development of Fast Tracker and its tracking performance for the ATLAS experiment. The Fast Tracker is a custom electronics system that will operate at the full Level 1 accepted rate of 100 kHz and provide...

  6. Fast motion-including dose error reconstruction for VMAT with and without MLC tracking

    DEFF Research Database (Denmark)

    Ravkilde, Thomas; Keall, Paul J.; Grau, Cai

    2014-01-01

    of the algorithm for reconstruction of dose and motion-induced dose errors throughout the tracking and non-tracking beam deliveries was quantified. Doses were reconstructed with a mean dose difference relative to the measurements of -0.5% (5.5% standard deviation) for cumulative dose. More importantly, the root...... validate a simple model for fast motion-including dose error reconstruction applicable to intrafractional QA of MLC tracking treatments of moving targets. MLC tracking experiments were performed on a standard linear accelerator with prototype MLC tracking software guided by an electromagnetic transponder......-mean-square deviation between reconstructed and measured motion-induced 3%/3 mm γ failure rates (dose error) was 2.6%. The mean computation time for each calculation of dose and dose error was 295 ms. The motion-including dose reconstruction allows accurate temporal and spatial pinpointing of errors in absorbed dose...

  7. Readmission rates after a planned hospital stay of 2 versus 3 days in fast-track colonic surgery

    DEFF Research Database (Denmark)

    Andersen, Jens; Hjort-Jakobsen, Dorthe; Christiansen, P. S.

    2007-01-01

    BACKGROUND: Initial programmes of fast-track open colonic surgery with a planned 2-day postoperative hospital stay have had a high readmission rate (about 20 per cent). The aim of this large, consecutive series was to compare readmission rates after a fast-track open colonic surgery programme....... There was no difference in type and incidence of morbidity between the two periods. CONCLUSION: Readmission after fast-track open colonic resection was reduced by planning discharge 3 instead of 2 days after surgery, with the same discharge criteria. Copyright (c) 2007 British Journal of Surgery Society Ltd. Published...... from August 2004. All patients were examined 8 and 30 days after surgery. RESULTS: Readmission rates fell from 20.1 per cent in 408 patients with a planned 2-day hospital stay (period 1) to 11.3 per cent in 133 patients with a planned 3-day hospital stay (period 2) (P

  8. Families' Divided: The place of the Family in Zimbabwe's Fast Track ...

    African Journals Online (AJOL)

    The political history and the political economy continue to mould the quality of life for most families in significant ways. Human beings have always lived in families from the beginning of time. The family is a pillar of society as it influences the way society is structured, organized and functions, yet the Fast Track Land Reform ...

  9. When is it optimal to delegate: the theory of fast-track authority

    Czech Academy of Sciences Publication Activity Database

    Celik, Levent; Karabay, Bilgehan; McLaren, J.

    2015-01-01

    Roč. 7, č. 3 (2015), s. 347-389 ISSN 1945-7669 R&D Projects: GA ČR(CZ) GAP402/12/0666 Institutional support: PRVOUK-P23 Keywords : fast-track authority * free trade * protectionist rents Subject RIV: AH - Economics Impact factor: 1.359, year: 2015

  10. A new approach for the screening of carotid lesions: a 'fast-track' method with the use of new generation hand-held ultrasound devices.

    Science.gov (United States)

    Aboyans, V; Lacroix, P; Jeannicot, A; Guilloux, J; Bertin, F; Laskar, M

    2004-09-01

    We assessed the usefulness of fast-track neck sonography with a new-generation hand-held ultrasound scanner in the detection of > or =60% carotid stenosis. Patients with a past history of atherosclerotic disease or presence of risk factors were enrolled. All had fast-track carotid screening with a hand-held ultrasound scanner. Initial assessment was performed with our quick imaging protocol. A second examiner performed a conventional complete carotid duplex as gold-standard. We enrolled 197 consecutive patients with a mean age of 67 years (range 35-94). A carotid stenosis >60% was detected in 13 cases (6%). The sensitivity, specificity, positive and negative predictive value of fast-track sonography was 100%, 64%, 17% and 100%, respectively. Concomitant power Doppler imaging during the fast-track method did not improve accuracy. The use of a fast-track method with a hand-held ultrasound device can reduce the number of unnecessary carotid Duplex and enhance the screening efficiency without missing significant carotid stenoses.

  11. Fast and Accurate Rat Head Motion Tracking With Point Sources for Awake Brain PET.

    Science.gov (United States)

    Miranda, Alan; Staelens, Steven; Stroobants, Sigrid; Verhaeghe, Jeroen

    2017-07-01

    To avoid the confounding effects of anesthesia and immobilization stress in rat brain positron emission tomography (PET), motion tracking-based unrestrained awake rat brain imaging is being developed. In this paper, we propose a fast and accurate rat headmotion tracking method based on small PET point sources. PET point sources (3-4) attached to the rat's head are tracked in image space using 15-32-ms time frames. Our point source tracking (PST) method was validated using a manually moved microDerenzo phantom that was simultaneously tracked with an optical tracker (OT) for comparison. The PST method was further validated in three awake [ 18 F]FDG rat brain scans. Compared with the OT, the PST-based correction at the same frame rate (31.2 Hz) reduced the reconstructed FWHM by 0.39-0.66 mm for the different tested rod sizes of the microDerenzo phantom. The FWHM could be further reduced by another 0.07-0.13 mm when increasing the PST frame rate (66.7 Hz). Regional brain [ 18 F]FDG uptake in the motion corrected scan was strongly correlated ( ) with that of the anesthetized reference scan for all three cases ( ). The proposed PST method allowed excellent and reproducible motion correction in awake in vivo experiments. In addition, there is no need of specialized tracking equipment or additional calibrations to be performed, the point sources are practically imperceptible to the rat, and PST is ideally suitable for small bore scanners, where optical tracking might be challenging.

  12. Influencing Factor of Postoperation Fast-track Recovery and in Hospital Cost after Lobctomy for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Jianhua SU

    2014-07-01

    Full Text Available Background and objective It is unknown that the postoperation fast-track recovery and in hospital cost of the lobectomy in lung cancer, we explored the influencing factor of postoperative fast-track recovery and in hospital cost after undergoing lobectomy for lung cancer. Methods We retrospectively reviewed the medical records of all patients (n=176 who underwent lobectomy for lung cancer between January 2010 and November 2011 by a thoracic surgeon. Results The hospital costs of video-assisted thoracic surgery (VATS lobectomy (47,308.21 ¥ is significantly higher than open lobectomy (45,664.31 ¥(P=0.007. The hospital costs of body mass index (BMI ≥ 24 kg/m2 (51,186.99 ¥ is significantly higher than BMI < 24 kg/m2 (41,701.64 ¥(P=0.032. The hospital stay of VATS lobectomy (5.70 d is significantly less than open lobectomy (7.10 d(P<0.001. Conclusion These findings indicate that preoperative pulmonary rehabilitation and VATS lobectomy is contributed to fast-track recovery for patients who undergo lobectomy, but increase the hospital costs.

  13. Cognitive dysfunction after fast-track hip and knee replacement.

    Science.gov (United States)

    Krenk, Lene; Kehlet, Henrik; Bæk Hansen, Torben; Solgaard, Søren; Soballe, Kjeld; Rasmussen, Lars Simon

    2014-05-01

    Postoperative cognitive dysfunction (POCD) is reported to occur after major surgery in as many as 20% of patients, elderly patients may especially experience problems in the weeks and months after surgery. Recent studies vary greatly in methods of evaluation and diagnosis of POCD, and the pathogenic mechanisms are still unclear. We evaluated a large uniform cohort of elderly patients in a standardized approach, after major joint replacement surgery (total hip and knee replacement). Patients were in an optimized perioperative approach (fast track) with multimodal opioid-sparing analgesia, early mobilization, and short length of stay (LOS ≤3 days) and discharged to home. In a prospective multicenter study, we included 225 patients aged ≥60 years undergoing well-defined fast-track total hip or total knee replacement. Patients had neuropsychological testing preoperatively and 1 to 2 weeks and 3 months postoperatively. LOS, pain, opioid use, inflammatory response, and sleep quality were recorded. The practice effect of repeated cognitive testing was gauged using data from a healthy community-dwelling control group (n = 161). Median LOS was 2 days (interquartile range 2-3). The incidence of POCD at 1 to 2 weeks was 9.1% (95% confidence interval [CI], 5.4%-13.1%) and 8.0% (95% CI, 4.5%-12.0%) at 3 months. There was no statistically significant difference between patients with and without early POCD, regarding pain, opioid use, sleep quality, or C-reactive protein response, although the CIs were wide. Patients with early POCD had a higher Mini Mental State Examination score preoperatively (difference in medians 0.5 [95% CI, -1.0% to 0.0%]; P = 0.034). If there was an association between early POCD and late POCD, the sample size was unfortunately too small to verify this (23.6% of patients with early POCD had late onset vs 6.7% in non-POCD group; risk difference 16.9 (95% CI, -2.1% to 41.1%; P = 0.089). The incidence of POCD early after total hip and knee replacement

  14. Fast Poisson Solvers for Self-Consistent Beam-Beam and Space-Charge Field Computation in Multiparticle Tracking Simulations

    CERN Document Server

    Florio, Adrien; Pieloni, Tatiana; CERN. Geneva. ATS Department

    2015-01-01

    We present two different approaches to solve the 2-dimensional electrostatic problem with open boundary conditions to be used in fast tracking codes for beam-beam and space charge simulations in high energy accelerators. We compare a fast multipoles method with a hybrid Poisson solver based on the fast Fourier transform and finite differences in polar coordinates. We show that the latter outperforms the first in terms of execution time and precision, allowing for a reduction of the noise in the tracking simulation. Furthermore the new algorithm is shown to scale linearly on parallel architectures with shared memory. We conclude by effectively replacing the HFMM by the new Poisson solver in the COMBI code.

  15. Fast regional readout CMOS Image Sensor for dynamic MLC tracking

    Science.gov (United States)

    Zin, H.; Harris, E.; Osmond, J.; Evans, P.

    2014-03-01

    Advanced radiotherapy techniques such as volumetric modulated arc therapy (VMAT) require verification of the complex beam delivery including tracking of multileaf collimators (MLC) and monitoring the dose rate. This work explores the feasibility of a prototype Complementary metal-oxide semiconductor Image Sensor (CIS) for tracking these complex treatments by utilising fast, region of interest (ROI) read out functionality. An automatic edge tracking algorithm was used to locate the MLC leaves edges moving at various speeds (from a moving triangle field shape) and imaged with various sensor frame rates. The CIS demonstrates successful edge detection of the dynamic MLC motion within accuracy of 1.0 mm. This demonstrates the feasibility of the sensor to verify treatment delivery involving dynamic MLC up to ~400 frames per second (equivalent to the linac pulse rate), which is superior to any current techniques such as using electronic portal imaging devices (EPID). CIS provides the basis to an essential real-time verification tool, useful in accessing accurate delivery of complex high energy radiation to the tumour and ultimately to achieve better cure rates for cancer patients.

  16. Fast regional readout CMOS image sensor for dynamic MLC tracking

    International Nuclear Information System (INIS)

    Zin, H; Harris, E; Osmond, J; Evans, P

    2014-01-01

    Advanced radiotherapy techniques such as volumetric modulated arc therapy (VMAT) require verification of the complex beam delivery including tracking of multileaf collimators (MLC) and monitoring the dose rate. This work explores the feasibility of a prototype Complementary metal-oxide semiconductor Image Sensor (CIS) for tracking these complex treatments by utilising fast, region of interest (ROI) read out functionality. An automatic edge tracking algorithm was used to locate the MLC leaves edges moving at various speeds (from a moving triangle field shape) and imaged with various sensor frame rates. The CIS demonstrates successful edge detection of the dynamic MLC motion within accuracy of 1.0 mm. This demonstrates the feasibility of the sensor to verify treatment delivery involving dynamic MLC up to ∼400 frames per second (equivalent to the linac pulse rate), which is superior to any current techniques such as using electronic portal imaging devices (EPID). CIS provides the basis to an essential real-time verification tool, useful in accessing accurate delivery of complex high energy radiation to the tumour and ultimately to achieve better cure rates for cancer patients.

  17. Postoperative Urinary Catheterization Thresholds of 500 versus 800 ml after Fast-track Total Hip and Knee Arthroplasty

    DEFF Research Database (Denmark)

    Bjerregaard, Lars Stryhn; Hornum, Ulla Marianne; Troldborg, C.

    2016-01-01

    arthroplasty (THA) and total knee arthroplasty (TKA). METHODS: This was a randomized, controlled, open-label trial that included patients greater than or equal to 18 yr who underwent THA or TKA in three Danish, fast-track, orthopedic departments. Consenting patients were eligible if they were cooperative......BACKGROUND: No evidence-based threshold exists for postoperative urinary bladder catheterization. The authors hypothesized that a catheterization threshold of 800 ml was superior to 500 ml in reducing postoperative urinary catheterization and urological complications after fast-track total hip...

  18. A Midsize Tokamak As Fast Track To Burning Plasmas

    International Nuclear Information System (INIS)

    Mazzucato, E.

    2010-01-01

    This paper presents a midsize tokamak as a fast track to the investigation of burning plasmas. It is shown that it could reach large values of energy gain ((ge) 10) with only a modest improvement in confinement over the scaling that was used for designing the International Thermonuclear Experimental Reactor (ITER). This could be achieved by operating in a low plasma recycling regime that experiments indicate can lead to improved plasma confinement. The possibility of reaching the necessary conditions of low recycling using a more efficient magnetic divertor than those of present tokamaks is discussed.

  19. Variation in 'fast-track' referrals for suspected cancer by patient characteristic and cancer diagnosis: evidence from 670 000 patients with cancers of 35 different sites.

    Science.gov (United States)

    Zhou, Y; Mendonca, S C; Abel, G A; Hamilton, W; Walter, F M; Johnson, S; Shelton, J; Elliss-Brookes, L; McPhail, S; Lyratzopoulos, G

    2018-01-01

    In England, 'fast-track' (also known as 'two-week wait') general practitioner referrals for suspected cancer in symptomatic patients are used to shorten diagnostic intervals and are supported by clinical guidelines. However, the use of the fast-track pathway may vary for different patient groups. We examined data from 669 220 patients with 35 cancers diagnosed in 2006-2010 following either fast-track or 'routine' primary-to-secondary care referrals using 'Routes to Diagnosis' data. We estimated the proportion of fast-track referrals by sociodemographic characteristic and cancer site and used logistic regression to estimate respective crude and adjusted odds ratios. We additionally explored whether sociodemographic associations varied by cancer. There were large variations in the odds of fast-track referral by cancer (P<0.001). Patients with testicular and breast cancer were most likely to have been diagnosed after a fast-track referral (adjusted odds ratios 2.73 and 2.35, respectively, using rectal cancer as reference); whereas patients with brain cancer and leukaemias least likely (adjusted odds ratios 0.05 and 0.09, respectively, for brain cancer and acute myeloid leukaemia). There were sex, age and deprivation differences in the odds of fast-track referral (P<0.013) that varied in their size and direction for patients with different cancers (P<0.001). For example, fast-track referrals were least likely in younger women with endometrial cancer and in older men with testicular cancer. Fast-track referrals are less likely for cancers characterised by nonspecific presenting symptoms and patients belonging to low cancer incidence demographic groups. Interventions beyond clinical guidelines for 'alarm' symptoms are needed to improve diagnostic timeliness.

  20. First results of the silicon telescope using an 'artificial retina' for fast track finding

    Energy Technology Data Exchange (ETDEWEB)

    Neri, N. [Istituto Nazionale di Fisica Nucleare - INFN, Sezione di Milano, Milano (Italy); Abba, A.; Caponio, F.; Geraci, A.; Grizzuti, M.; Lusardi, N. [INFN Milano and Politecnico di Milano, Milano (Italy); Citterio, M.; Coelli, S.; Fu, J.; Monti, M.; Petruzzo, M. [INFN Milano, Milano (Italy); Bedeschi, F.; Ninci, D.; Piucci, A.; Spinella, F.; Walsh, J. [INFN Pisa, Pisa (Italy); Cenci, R.; Marino, P.; Morello, M. J.; Stracka, S. [INFN Pisa and Scuola Normale Superiore di Pisa, Pisa (Italy); Punzi, G. [INFN Pisa and Universita di Pisa, Pisa (Italy); Tonelli, D. [CERN, Geneva (Switzerland); Ristori, L. [INFN Pisa, Pisa (Italy); Fermilab, Batavia, Illinois (United States)

    2015-07-01

    We present the first results of the prototype of a silicon tracker with trigger capabilities based on a novel approach for fast track finding. The working principle of the 'artificial retina' is inspired by the processing of visual images by the brain and it is based on extensive parallelization of data distribution and pattern recognition. The algorithm has been implemented in commercial FPGAs in three main logic modules: a switch for the routing of the detector hits, a pool of engines for the digital processing of the hits, and a block for the calculation of the track parameters. The architecture is fully pipelined and allows the reconstruction of real-time tracks with a latency less then 100 clock cycles, corresponding to 0.25 microsecond at 400 MHz clock. The silicon telescope consists of 8 layers of single-sided silicon strip detectors with 512 strips each. The detector size is about 10 cm x 10 cm and the strip pitch is 183 μm. The detectors are read out by the Beetle chip, a custom ASICs developed for LHCb, which provides the measurement of the hit position and pulse height of 128 channels. The 'artificial retina' algorithm has been implemented on custom data acquisition boards based on FPGAs Xilinx Kintex 7 lx160. The parameters of the tracks detected are finally transferred to host PC via USB 3.0. The boards manage the read-out ASICs and the sampling of the analog channels. The read-out is performed at 40 MHz on 4 channels for each ASIC that corresponds to a decoding of the telescope information at 1.1 MHz. We report on the first results of the fast tracking device and compare with simulations. (authors)

  1. Most patients regain prefracture basic mobility after hip fracture surgery in a fast-track programme

    DEFF Research Database (Denmark)

    Kristensen, Morten Tange; Kehlet, Henrik

    2012-01-01

    Treatment of patients with hip fracture has improved over the past decade. Still, some patients do not regain independent mobility within their primary hospital stay even if they follow a multimodal fast-track surgical programme. The aim of the present article was to examine the validity of the p......Treatment of patients with hip fracture has improved over the past decade. Still, some patients do not regain independent mobility within their primary hospital stay even if they follow a multimodal fast-track surgical programme. The aim of the present article was to examine the validity...... of the preliminary prefracture New Mobility Score (NMS), age and fracture type as independent predictors of in-hospital outcome after hip fracture surgery....

  2. LiTrack: A Fast Longitudinal Phase Space Tracking Code with Graphical User Interface

    International Nuclear Information System (INIS)

    Bane, K.L.F.

    2005-01-01

    Linac-based light sources and linear colliders typically apply longitudinal phase space manipulations in their design, including electron bunch compression and wakefield-induced energy spread control. Several computer codes handle such issues, but most also require detailed information on the transverse focusing lattice. In fact, in most linear accelerators, the transverse distributions do not significantly affect the longitudinal, and can be ignored initially. This allows the use of a fast 2D code to study longitudinal aspects without time-consuming considerations of the transverse focusing. LiTrack is based on a 15-year old code (same name) originally written by one of us (KB), which is now a Matlab [1] code with additional features, such as graphical user interface, prompt output plotting, and functional call within a script. This single-bunch tracking code includes RF acceleration, bunch compression to 3rd order, geometric and resistive short-range wakefields, aperture limits, synchrotron radiation, and flexible output plotting. The code was used to design both the LCLS [2] and the SPPS [3] projects at SLAC and typically runs 10 5 particles in < 1 minute. We describe the features, show some examples, and provide free access to the code

  3. Safeguarding Self-Governance: A Grounded Theory of Older Patients’ Pattern of Behavior in Relation to their Relatives in Fast-track Programs

    DEFF Research Database (Denmark)

    Berthelsen, Connie B.; Frederiksen, Kirsten; Lindhardt Damsgaard, Tove

    2014-01-01

    Abstract The aim of this study was to generate a grounded theory of older patients’ pattern of behavior in relation to their relatives’ involvement in fast-track programs during total joint replacement. Sixteen patients were recruited in orthopedic wards. Data collection included 11 interviews......, shielding, distancing, and masking. Keywords: Fast-track program, grounded theory, older patients, relatives, total joint replacement.......-governance emerged in the analysis as the core category of our theory and pattern of behavior of the older patients in relation to their relatives. The older patients’ main concern was to complete the fast-track program while maintaining autonomy, which they resolved through four strategies of actions: embracing...

  4. Surgical Stress Response and Postoperative Immune Function After Laparoscopy or Open Surgery With Fast Track or Standard Perioperative Care A Randomized Trial

    NARCIS (Netherlands)

    Veenhof, A. A. F. A.; Vlug, M. S.; van der Pas, M. H. G. M.; Sietses, C.; van der Peet, D. L.; de Lange-de Klerk, E. S. M.; Bonjer, H. J.; Bemelman, W. A.; Cuesta, M. A.

    2012-01-01

    Objective: To evaluate the effect of laparoscopic or open colectomy with fast track or standard perioperative care on patient's immune status and stress response after surgery. Methods: Patients with nonmetastasized colon cancer were randomized to laparoscopic or open colectomy with fast track or

  5. Fast-track program in laparoscopic liver surgery: Theory or fact?

    Science.gov (United States)

    Sánchez-Pérez, Belinda; Aranda-Narváez, José Manuel; Suárez-Muñoz, Miguel Angel; Eladel-Delfresno, Moises; Fernández-Aguilar, José Luis; Pérez-Daga, Jose Antonio; Pulido-Roa, Ysabel; Santoyo-Santoyo, Julio

    2012-11-27

    To analyze our results after the introduction of a fast-track (FT) program after laparoscopic liver surgery in our Hepatobiliarypancreatic Unit. All patients (43) undergoing laparoscopic liver surgery between March 2004 and March 2010 were included and divided into two consecutive groups: Control group (CG) from March 2004 until December 2006 with traditional perioperative cares (17 patients) and fast-track group (FTG) from January 2007 until March 2010 with FT program cares (26 patients). Primary endpoint was the influence of the program on the postoperative stay, the amount of re-admissions, morbidity and mortality. Secondarily we considered duration of surgery, use of drains, conversion to open surgery, intensive cares needs and transfusion. Both groups were homogeneous in age and sex. No differences in technique, time of surgery or conversion to open surgery were found, but more malignant diseases were operated in the FTG, and then transfusions were higher in FTG. Readmissions and morbidity were similar in both groups, without mortality. Postoperative stay was similar, with a median of 3 for CG vs 2.5 for FTG. However, the 80.8% of patients from FTG left the hospital within the first 3 d after surgery (58.8% for CG). The introduction of a FT program after laparoscopic liver surgery improves the recovery of patients without increasing complications or re-admissions, which leads to a reduction of the stay and costs.

  6. Design of a 300-Watt Isolated Power Supply for Ultra-Fast Tracking Converters

    DEFF Research Database (Denmark)

    Nguyen-Duy, Khiem; Ouyang, Ziwei; Petersen, Lars Press

    2015-01-01

    This paper presents the design of a medium-powerrating isolated power supply for ultra-fast tracking converters and MOS-gate driver circuits in medium and high voltage applications. The key feature of the design is its very low circuit input-to-output parasitic capacitance, which maximizes its...

  7. High patient satisfaction in 445 patients who underwent fast-track hip or knee replacement

    DEFF Research Database (Denmark)

    Specht, Kirsten; Kjaersgaard-Andersen, Per; Kehlet, Henrik

    2015-01-01

    BACKGROUND AND PURPOSE: Patient satisfaction is important in fast-track total hip and knee replacement (THR, TKR). We assessed: (1) how satisfied patients were with the treatment; (2) factors related to overall satisfaction; and (3) whether there was a difference between THR and TKR regarding...... length of stay (LOS) and patient satisfaction. PATIENTS AND METHODS: In this follow-up study, a consecutive series of 445 patients undergoing THR and TKR completed a questionnaire 2 weeks after discharge. LOS and short-term patient satisfaction with the fast-track management were measured. Patient...... satisfaction was measured using a numerical rating scale (NRS; 0-10). RESULTS: For THR, the median satisfaction score was 9-10 and for TKR it was 8.5-10 in all parameters. Older THR patients had higher overall satisfaction. No association was found between overall satisfaction following THR or TKR and sex...

  8. Cognitive dysfunction after fast-track hip and knee replacement

    DEFF Research Database (Denmark)

    Krenk, Lene; Kehlet, Henrik; Bæk Hansen, Torben

    2014-01-01

    to 2 weeks and 3 months postoperatively. LOS, pain, opioid use, inflammatory response, and sleep quality were recorded. The practice effect of repeated cognitive testing was gauged using data from a healthy community-dwelling control group (n = 161). RESULTS: Median LOS was 2 days (interquartile range...... this (23.6% of patients with early POCD had late onset vs 6.7% in non-POCD group; risk difference 16.9 (95% CI, -2.1% to 41.1%; P = 0.089). CONCLUSIONS: The incidence of POCD early after total hip and knee replacement seems to be lower after a fast-track approach than rates previously reported...

  9. Fast neutron dosimetry by means of different solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Spurny, F.; Turek, K.

    1977-01-01

    The comparative study of three different types of fast neutron dosimeters based on solid state nuclear track detectors is presented; the dosimeters studied were: - microscopic soda glass in contact with 232 Th; - polycarbonate Makrofol E; and - cellulose nitrate Kodak LR 115. All detectors were evaluated by visual counting in a microscope. The authors have studied such properties as the background, angular as well as energetical dependences of detectors. The results obtained show that all studied detectors are suitable for fast neutron dosimetry; their application depends however on the concrete experimental conditions (neutron spectrum, fluence etc.). Both advantages and disadvantages of each of them are presented. (Auth.)

  10. Electrochemical etching amplification of low-let recoil particle tracks in polymers for fast neutron dosimetry

    International Nuclear Information System (INIS)

    Sohrabi, M.; Morgan, K.Z.

    1975-11-01

    An electrochemical etching method for the amplification of fast-neutron-induced recoil particle tracks in polymers was investigated. The technique gave superior results over those obtained by conventional etching methods especially when polycarbonate foils were used for recoil particle track amplification. Electrochemical etching systems capable of multi-foil processing were designed and constructed to demonstrate the feasibility of the techniques for large-scale neutron dosimetry. Electrochemical etching parameters were studied including the nature or type of the polymer foil used, foil thickness and its effect on etching time, the applied voltage and its frequency, the chemical composition, concentration, and temperature of the etchant, distance and angle between the electrodes, and the type of particles such as recoil particles including protons. Recoil particle track density, mean track diameter, and optical density as functions of the mentioned parameters were determined. Each parameter was found to have a distinct effect on the etching results in terms of the measured responses. Several new characteristics of this fast neutron dosimetry method were studied especially for personnel dosimetry using various radiation sources such as nuclear reactors, medical cyclotrons, and isotopic neutron sources. The dose range, neutron energy dependence, directional response, fading characteristics, neutron threshold energy, etc. were investigated

  11. Fast-track, ambulatory ultrasound-guided Tru-Cut liver biopsy is feasible and cost-efficient

    DEFF Research Database (Denmark)

    Huang, Chenxi; Lorentzen, Torben; Skjoldbye, Bjørn

    2015-01-01

    safely discharged from our institution. No fatality or long-term complications were found during this study. CONCLUSION: The fast-track approach reported herein is a feasible option when adequate patient information is given. Besides the obvious, positive effect on patient logistics and departmental...

  12. Fast Tracker : A Hardware Real Time Track Finder for the ATLAS Trigger System

    CERN Document Server

    Kimura, N; The ATLAS collaboration

    2013-01-01

    The Large Hadron Collider (LHC) after the 2013-­‐2014 shutdown period is expected to improve the yet impressive performance obtained up to this year: collisions’ energy will increase to 14 TeV and instantaneous luminosity will reach and then overcome 10^34 cm‐2s‐1, with a bunch crossing period of 25 ns. The LHC experiments will need to adapt to the more crowded events, maintaining the physics output and the quality of the final results. The pileup higher than the LHC run 1, with peaks expected to reach 50 or more, will make more difficult to have efficient online selection of rare events based mostly on calorimeters and muon detectors as it is done now. A more extensive use of the information collected by the tracking detector will allow building more robust selections, limiting the degradation effects due to the high pileup. We report on the development of the Fast Tracker (FTK) processor for the ATLAS experiment, devoted to reconstruct tracks with transverse momentum above 1 GeV in the whole detect...

  13. Fast neutron detection by means of an organic solid state track detector

    International Nuclear Information System (INIS)

    Doerschel, B.; Streubel, G.

    1980-01-01

    Solid state track detectors consisting of cellulose triacetate foils are appropriate for measuring the fast neutron fluence without applying external radiators. Detector sensitivity has been determined as a function of neutron energy by performing irradiations with various neutron sources and monoenergetic neutrons of different energies. A comparison with theoretical results given in the literature for a simple model of track recording has shown sufficient agreement. The measuring errors and the influence of spectral changes in the neutron field on detector response are discussed for the studied method of fluence measurement. By means of these errors the measuring range has been determined for well defined irradiation conditions, taking into account spectral changes in the neutron field. (author)

  14. Nopea toipuminen lihavuusleikkauksen jälkeen : Fast track- toimintamallin mukainen potilasohjausvihko lihavuusleikkauspotilaalle Oulun yliopistollisen sairaalan osastolle yhdeksän

    OpenAIRE

    Niskala, Jenni; Nevala, Elisa

    2013-01-01

    Oulun yliopistollisen sairaalan osastolla yhdeksän oli tarve saada Fast track -toimintamallin mukainen potilasohjausvihko lihavuusleikkauspotilaille. Opinnäytetyön tekijät valitsivat opinnäytetyön aiheen perioperatiivisen suuntautumisvaihtoehdon mukaan. Tämä opinnäytetyö toteutettiin projektityönä. Opinnäytetyön tarkoituksena oli tehdä Fast track- toimintamallin mukainen potilasohjausvihko Oulun Yliopistollisen sairaalan osasto yhdeksän käyttöön. Opinnäytetyön tavoitteena oli edesauttaa ...

  15. Tracking Your Development

    CERN Document Server

    Hennum, Kelly M

    2011-01-01

    This book provides you with the means to set development goals and to track your progress on achieving them. It can help you efficiently gather and make sense of information about your progress and avoid common pitfalls that can block your development. Tracking your development can be captures in a few steps: articulating your goal, creating an action plan, gathering information about your behavior, indentifying barriers and support, and revising your action plan. Taking these steps will greatly increase the likelihood of achieving your goals.

  16. Development of nuclear track detectors

    International Nuclear Information System (INIS)

    Somogyi, Gyoergy

    1985-01-01

    The birth and development of two decades of a new nuclear detection method is briefly summarized by one of the first inventors. The main steps of the development and broadening application of nuclear solid state track detectors are described underlying the contribution and main results of the research group of ATOMKI, Hungary (i.e. the finding of the proper plastic materials for track detectors, the discovery of correlations between the track diameter and the particle energy, the increasing of energy resolution, explanation of the track developing process, elaboration of new electrochemical track analyzing methods and automatic track analyzers). Recently, this detecting technique has grown to the phase of the industrial mass production and broad application in radiogeochemistry, mining, radioecology, personal monitoring in nuclear power plants, etc. (D.Gy.)

  17. Impact of fast-track concept elements in the classical pancreatic head resection (Kausch-Whipple procedure).

    Science.gov (United States)

    Gastinger, Ingo; Meyer, Frank; Lembcke, Thomas; Schmidt, Uwe; Ptok, Henry; Lippert, Hans

    2012-08-01

    The aim of the study was to determine statistically significant factors with an impact on the early postoperative surgical outcome. The influence of applied fast-track components on surgical results and early postoperative outcome in 143 consecutive Kausch-Whipple procedure patients was evaluated in a single-center retrospective analysis of a prospective collection of patient-associated pre-, peri- and postoperative data from 1997-2006. The in-hospital mortality rate was 2.8% (n=4). Fast-track measures were shown to have no effect on the morbidity rate in the multi-variate analysis. Over the study period, a decrease of intraoperative infusion volume from 14.2 mL/kg body weight/h in the first year to 10.7 mL/kg body weight/h in the last year was accompanied by an increase in patients requiring intraoperative catecholamines, up from 17% to 95%. The administration of ropivacain/sufentanil via thoracic peri-dural catheter injection initiated in 2000 and now considered the leading analgesic method, was used in 95% of the cases in 2006. Early extubation rate rose from 16.6% to 57.9%. Fast-track aspects in the perioperative management have become more important in several surgical procedure even in those with a greater invasiveness such as Kausch-Whipple. However, such techniques used in peri-operative management of Kausch-Whipple pancreatic-head resections had no impact on the morbidity rate. In addition, the low in-hospital mortality rate was particularly attributed to surgical competence.

  18. Fast Tracker: A Hardware Real Time Track Finder for the ATLAS Trigger System

    CERN Document Server

    Kimura, N; The ATLAS collaboration

    2014-01-01

    The Fast Tracker (FTK) is an integral part of the trigger upgrade program for the ATLAS detector at the Large Hadron Collider (LHC). As the LHC luminosity approaches its design level of 10^34cm^−2s^−1, the combinatorial problem posed by charged particle tracking becomes increasingly difficult due to the swelling of multiple interactions per bunch crossing (pile-up). The FTK is a highly-parallel hardware system intended to provide high-quality tracks with transverse momentum above 1 GeV/c in real time for online trigger system. The FTK system’s design, based on a mixture of advanced technologies, and expected physics performance will be presented.

  19. Laparoscopy in combination with fast track multimodal management is the best perioperative strategy in patients undergoing colonic surgery: a randomized clinical trial (LAFA-study)

    NARCIS (Netherlands)

    Vlug, Malaika S.; Wind, Jan; Hollmann, Markus W.; Ubbink, Dirk T.; Cense, Huib A.; Engel, Alexander F.; Gerhards, Michael F.; van Wagensveld, Bart A.; van der Zaag, Edwin S.; van Geloven, Anna A. W.; Sprangers, Mirjam A. G.; Cuesta, Miguel A.; Bemelman, Willem A.; Preckel, Benedikt; Bossuyt, Patrick; Gouma, Dirk; van Berge Henegouwen, Mark; Fuhring, Jan; van Lenthe, Ineke Picard; Bakker, Chris; King-Kalimanis, Bellinda; Hofland, Jan; Dejong, Cornelis; van Dam, Ronald; van der Peet, Donald; van Zalingen, Edith; Noordhuis, Astrid; de Jong, Dick; Goei, T. Hauwy; de Stoppelaar, Erica; van den Dongen, Marjon; van Tets, Willem; van den Elsen, Maarten; Swart, Annemiek; deWit, Laurens; Siepel, Muriel; Molly, Glaresa; Juttmann, Jan; Clevers, Wilfred; Bieleman, Andrea; Coenen, Ludo; Bonekamp, Elly; van Abeelen, Jacobus; van Iterson-de Jong, Diana; Krombeen, Margriet

    2011-01-01

    To investigate which perioperative treatment, ie, laparoscopic or open surgery combined with fast track (FT) or standard care, is the optimal approach for patients undergoing segmental resection for colon cancer. Important developments in elective colorectal surgery are the introduction of

  20. "Joined up" Thinking? Unsupported "Fast-Track" Transitions in the Context of Parental Substance Use

    Science.gov (United States)

    Wilson, Sarah; Cunningham-Burley, Sarah; Bancroft, Angus; Backett-Milburn, Kathryn

    2008-01-01

    Recent policy responses to the risks entailed in "fast-track" school-work transitions have targeted careleavers and young people identified as "not in education, employment or training" (NEET). However, this approach has been criticised as diverting attention away from the fragile circumstances of others who may receive little…

  1. Contrast agent bolus tracking with a fixed threshold or a manual fast start for coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Stenzel, Fabian; Rief, Matthias; Zimmermann, Elke; Greupner, Johannes; Richter, Felicitas; Dewey, Marc [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany)

    2014-06-15

    Comparison of bolus tracking with a fixed threshold versus a manual fast start for coronary CT angiography. We retrospectively analysed 320-row coronary CT angiography of 50 patients with suspected or known coronary artery disease. Twenty-five examinations were initiated by a bolus tracking method (group 1), 25 examinations with a manual fast surestart (group 2). Mean attenuation values in the ascending aorta were 519 ± 111 Hounsfield units (HU) in group 1 and 476 ± 65 HU in group 2 (p = 0.10). Assessable vessel lengths were 171 ± 44 mm vs 172 ± 29 mm for the right coronary artery (p = 0.91), 11 ± 4 mm vs 12 ± 4 mm for the left main (p = 0.9), 163 ± 28 mm vs 151 ± 26 mm for the left anterior descending coronary artery (p = 0.11) and 125 ± 41 mm vs 110 ± 37 mm for the left circumflex coronary artery (p = 0.18). Image quality for all coronary arteries was not significantly different between the groups (p > 0.41). The attenuation ratio between the left and right ventricle was 2.8 ± 0.7 vs 3.6 ± 1.0 (p = 0.003). Significantly less contrast agent was used in group 2 (64 ± 6 ml vs 80 ± 0 ml; p < 0.001). Bolus tracking with a fixed threshold and with a manual fast start are both suitable methods; the fast start allowed a reduction of contrast agent volumes. (orig.)

  2. The Mass Tracking System for the Integral Fast Reactor fuel cycle

    International Nuclear Information System (INIS)

    Adams, C.H.; Beitel, J.C.; Birgersson, G.; Bucher, R.G.; Carrico, C.B.; Daly, T.A.; Keyes, R.W.

    1994-01-01

    As part of the Fuel Cycle Facility (FCF) of Argonne National Laboratory's Integral Fast Reactor (IFR) demonstration, a computer-based Mass-Tracking (MTG) System has been developed. The MTG System collects, stores, retrieves and processes data on all operations which directly affect the flow of process material through FCF and supports such activities as process modeling, compliance with operating limits (e.g., criticality safety), material control and accountability and operational information services. Its architecture is client/server, with input and output connections to operator's equipment-control stations on the floor of FCF as well as to terminal sessions. Its heterogeneous database includes a relational-database manager as well as both binary and ASCII data files. The design of the database, and the software that supports it, is based on a model of discrete accountable items distributed in space and time and constitutes a complete historical record of the material processed in FCF. Although still under development, much of the MTG System has been qualified and is in production use

  3. Fast parallel tracking algorithm for the muon detector of the CBM experiment at FAIR

    International Nuclear Information System (INIS)

    Lebedev, A.; Hoehne, C.; Kisel', I.; Ososkov, G.

    2010-01-01

    Particle trajectory recognition is an important and challenging task in the Compressed Baryonic Matter (CBM) experiment at the future FAIR accelerator at Darmstadt. The tracking algorithms have to process terabytes of input data produced in particle collisions. Therefore, the speed of the tracking software is extremely important for data analysis. In this contribution, a fast parallel track reconstruction algorithm, which uses available features of modern processors is presented. These features comprise a SIMD instruction set (SSE) and multithreading. The first allows one to pack several data items into one register and to operate on all of them in parallel thus achieving more operations per cycle. The second feature enables the routines to exploit all available CPU cores and hardware threads. This parallel version of the tracking algorithm has been compared to the initial serial scalar version which uses a similar approach for tracking. A speed-upfactor of 487 was achieved (from 730 to 1.5 ms/event) for a computer with 2 x Intel Core 17 processors at 2.66 GHz

  4. Hardware-based Tracking at Trigger Level for ATLAS the Fast TracKer (FTK) Project

    CERN Document Server

    INSPIRE-00245767

    2015-01-01

    Physics collisions at 13 TeV are expected at the LHC with an average of 40-50 proton-proton collisions per bunch crossing under nominal conditions. Tracking at trigger level is an essential tool to control the rate in high-pileup conditions while maintaining a good efficiency for relevant physics processes. The Fast TracKer is an integral part of the trigger upgrade for the ATLAS detector. For every event passing the Level-1 trigger (at a maximum rate of 100 kHz) the FTK receives data from all the channels of the silicon detectors, providing tracking information to the High Level Trigger in order to ensure a selection robust against pile-up. The FTK performs a hardware-based track reconstruction, using associative memory that is based on the use of a custom chip, designed to perform pattern matching at very high speed. It finds track candidates at low resolution (roads) that seed a full-resolution track fitting done by FPGAs. An overview of the FTK system with focus on the pattern matching procedure will be p...

  5. A Fast Track towards the `Higgs' Spin and Parity

    CERN Document Server

    Ellis, John; Sanz, Veronica; You, Tevong

    2012-01-01

    The LHC experiments ATLAS and CMS have discovered a new boson that resembles the long-sought Higgs boson: it cannot have spin one, and has couplings to other particles that increase with their masses, but the spin and parity remain to be determined. We show here that the `Higgs' + gauge boson invariant-mass distribution in `Higgs'-strahlung events at the Tevatron or the LHC would be very different under the J^P = 0+, 0- and 2+ hypotheses, and could provide a fast-track indicator of the `Higgs' spin and parity. Our analysis is based on simulations of the experimental event selections and cuts using PYTHIA and Delphes, and incorporates statistical samples of `toy' experiments.

  6. A midsize tokamak as a fast track to burning plasmas

    Directory of Open Access Journals (Sweden)

    E. Mazzucato

    2011-03-01

    Full Text Available This paper describes the conceptual design of a midsize tokamak as a fast track to the investigation of burning plasmas. It is shown that it could reach large values of energy gain (≥ 10 with only a modest improvement in confinement over the scaling that was used for designing the International Thermonuclear Experimental Reactor (ITER. This can be achieved by operating in a low plasma recycling regime that experiments indicate can lead to improved plasma confinement. The possibility of reaching the necessary conditions of low recycling using a different magnetic divertor from those currently employed in present experiments is discussed.

  7. A Comparative Study of Analog Voltage-mode Control Methods for Ultra-Fast Tracking Power Supplies

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2007-01-01

    This paper presents a theoretical and experimental comparison of the standard PWM/PID voltage-mode control method for single-phase buck converters with two highperformance self-oscillating (a.k.a. sliding mode) control methods. The application considered is ultra-fast tracking power supplies...... (UFTPSs) for RF power amplifiers, where the switching converter needs to track a varying reference voltage precisely and quickly while maintaining low output impedance. The small-signal analyses performed on the different controllers show that the hysteretic-type controller can achieve the highest loop...

  8. Surgery-induced changes and early recovery of hip-muscle strength, leg-press power, and functional performance after fast-track total hip arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Thorborg, Kristian; Husted, Henrik

    2013-01-01

    By measuring very early changes in muscle strength and functional performance after fast-track total hip arthroplasty (THA), post-operative rehabilitation, introduced soon after surgery, can be designed to specifically target identified deficits.......By measuring very early changes in muscle strength and functional performance after fast-track total hip arthroplasty (THA), post-operative rehabilitation, introduced soon after surgery, can be designed to specifically target identified deficits....

  9. Opportune acquisition and tracking time for the fast-moving targets in a ground-based telescope

    Science.gov (United States)

    Chen, Juan; Wang, Jianli; Chen, Tao

    2004-10-01

    Acquisition is defined as identification for a fixed target in the related field of sight (FOS), while tracking means the sway of the telescope's axis of sight (AOS). The automatic acquisition and tracking is a process in which the operating way of the telescope should be switched from guiding to automatic tracking. There are some kinds of method to improve the acquisition and tracking ability for fast moving targets: to extend the acquisition and tracking FOS with memory and storage information of the sensor system; the multimode control to improve the dynamic property of the servo system; to choose an opportune time for acquisition and tracking; to select the control regulator parameter in every working states. If the processor of the CCD sensor can temporarily remember and save the information of the target before it moves out of the FOS, correspondingly, the FOS may be extended. The data forecast technology is used to store the target information. The automatic interception experiments are carried out to verify the control strategy.

  10. Improving the ATLAS physics potential with the Fast Track Trigger System

    CERN Document Server

    Cavaliere, Viviana; The ATLAS collaboration

    2015-01-01

    The ATLAS Fast TracKer (FTK) is a custom electronics system that will operate at the full Level-1 accept rate, 100 kHz, to provide high quality tracks as input to the High-Level Trigger. The event reconstruction is performed in hardware, thanks to the massive parallelism of associative memories (AM) and FPGAs. We present the advantages for the physics goals of the ATLAS experiment and the recent results on the design, technological advancements and testing of some of the core components used in the processor.

  11. MANAJEMEN RISIKO PADA PROYEK KONSTRUKSI DENGAN METODE FAST TRACK STUDI KASUS PROYEK QUNCI VILLAS DAN PUTRI NAGA KOMODO

    Directory of Open Access Journals (Sweden)

    I Gusti Ketut Wirawan

    2015-07-01

    Full Text Available The rapid economic development such as now day, it need a construction method that may provide a facility faster and less cost. Therefore, fast track method has been widely applied in project management as happened in Qunci Villas Project at Lombok and Putri Naga Komodo Project at Loh Liang of Komodo Island. Fast track construction method has potential risks that can interfere the success of the project. This study aims to identify the risks, especially the mayor risk, to formulate the mitigation action, and to determine the risk ownership. This study was conducted using qualitative descriptive method by identifying the risks arising during the implementation of the fast track method on Qunci Villas and Putri Naga Komodo Projects through the study of literature, brainstorming, interview using questionnaires to those who knew or were involved in the project. So the frequency and magnitude of the consequences of each risk can be known. Then the risk assessment can be conducted to determine the mayor risk and the minor risk. Then determining mitigation action for the mayor risk to reduce the negative impact that may arise. Then allocating the risk ownership in other to the mitigation action can be handled properly. The risk identified totaled 25 risks consisting of : 1 risk (4% which was medium risk rating,  6 risks (24% which were high risk rating, and 18 risks (72% which were extreme risk rating. The mayor risk amounted to 24 risks (96%. The mayor risk which were high risk rating consisting of : 1 planning risk, 3 technical risks, 1 project risk and 1 criminal risk. While mayor risk which were extreme risk rating consisting of : 5 technical risks, 10 project risks, 2 financial risks, and 1 human risk. Mitigation action were handled by reducing likelihood and consequence. The most risks ownership were allocated to the contractor.

  12. Fast-Acquisition/Weak-Signal-Tracking GPS Receiver for HEO

    Science.gov (United States)

    Wintemitz, Luke; Boegner, Greg; Sirotzky, Steve

    2004-01-01

    A report discusses the technical background and design of the Navigator Global Positioning System (GPS) receiver -- . a radiation-hardened receiver intended for use aboard spacecraft. Navigator is capable of weak signal acquisition and tracking as well as much faster acquisition of strong or weak signals with no a priori knowledge or external aiding. Weak-signal acquisition and tracking enables GPS use in high Earth orbits (HEO), and fast acquisition allows for the receiver to remain without power until needed in any orbit. Signal acquisition and signal tracking are, respectively, the processes of finding and demodulating a signal. Acquisition is the more computationally difficult process. Previous GPS receivers employ the method of sequentially searching the two-dimensional signal parameter space (code phase and Doppler). Navigator exploits properties of the Fourier transform in a massively parallel search for the GPS signal. This method results in far faster acquisition times [in the lab, 12 GPS satellites have been acquired with no a priori knowledge in a Low-Earth-Orbit (LEO) scenario in less than one second]. Modeling has shown that Navigator will be capable of acquiring signals down to 25 dB-Hz, appropriate for HEO missions. Navigator is built using the radiation-hardened ColdFire microprocessor and housing the most computationally intense functions in dedicated field-programmable gate arrays. The high performance of the algorithm and of the receiver as a whole are made possible by optimizing computational efficiency and carefully weighing tradeoffs among the sampling rate, data format, and data-path bit width.

  13. A reengineering success story: process improvement in emergency department x-ray cycle time, leading to breakthrough performance in the ED ambulatory care (Fast Track) process.

    Science.gov (United States)

    Espinosa, J A; Treiber, P M; Kosnik, L

    1997-01-01

    This article describes the journey of a multidisciplinary reengineering team, which worked to reduce a critical, high-leverage process in an emergency department setting. The process selected was emergency department radiology services. This process was selected on a rational basis. The team knew tht 60 percent of our emergency department patients were truly ambulatory, and that most could be seen in a "fast track" process as part of our emergency department's core mission. However, we knew from customer satisfaction data, that patients would like to be "in and out" of emergency department Fast Track in less than an hour. Over half of our Fast Track patients require x-rays. For most, this was their sole reason for seeking emergency care. Our state, at the start of the project, included an average x-ray cycle time of over 60 minutes. The associated Fast-Track cycle time was over 90 minutes median. It was clear to the emergency department leadership, as well as to members of the Fast-Track management team, that a cycle time of 30 minutes or less for x-ray service was needed as a necessary condition to an hour or less Fast Track cycle time. It was also felt that a more rapid x-ray cycle time would allow for more rapid turn over of ED rooms, leading to a virtual greater capacity to the ED. It was hoped that this would lead to a reduction in the time from arrival to treatment by the emergency physician for all patients.

  14. International collaborative project to compare and track the nutritional composition of fast foods

    Directory of Open Access Journals (Sweden)

    2012-07-01

    Full Text Available Abstract Background Chronic diseases are the leading cause of premature death and disability in the world with over-nutrition a primary cause of diet-related ill health. Excess quantities of energy, saturated fat, sugar and salt derived from fast foods contribute importantly to this disease burden. Our objective is to collate and compare nutrient composition data for fast foods as a means of supporting improvements in product formulation. Methods/design Surveys of fast foods will be done in each participating country each year. Information on the nutrient composition for each product will be sought either through direct chemical analysis, from fast food companies, in-store materials or from company websites. Foods will be categorized into major groups for the primary analyses which will compare mean levels of saturated fat, sugar, sodium, energy and serving size at baseline and over time. Countries currently involved include Australia, New Zealand, France, UK, USA, India, Spain, China and Canada, with more anticipated to follow. Discussion This collaborative approach to the collation and sharing of data will enable low-cost tracking of fast food composition around the world. This project represents a significant step forward in the objective and transparent monitoring of industry and government commitments to improve the quality of fast foods.

  15. International collaborative project to compare and track the nutritional composition of fast foods.

    Science.gov (United States)

    2012-07-27

    Chronic diseases are the leading cause of premature death and disability in the world with over-nutrition a primary cause of diet-related ill health. Excess quantities of energy, saturated fat, sugar and salt derived from fast foods contribute importantly to this disease burden. Our objective is to collate and compare nutrient composition data for fast foods as a means of supporting improvements in product formulation. Surveys of fast foods will be done in each participating country each year. Information on the nutrient composition for each product will be sought either through direct chemical analysis, from fast food companies, in-store materials or from company websites. Foods will be categorized into major groups for the primary analyses which will compare mean levels of saturated fat, sugar, sodium, energy and serving size at baseline and over time. Countries currently involved include Australia, New Zealand, France, UK, USA, India, Spain, China and Canada, with more anticipated to follow. This collaborative approach to the collation and sharing of data will enable low-cost tracking of fast food composition around the world. This project represents a significant step forward in the objective and transparent monitoring of industry and government commitments to improve the quality of fast foods.

  16. Faster recovery of gastrointestinal transit after laparoscopy and fast-track care in patients undergoing colonic surgery

    NARCIS (Netherlands)

    van Bree, Sjoerd; Vlug, Malaika; Bemelman, Willem; Hollmann, Markus; Ubbink, Dirk; Zwinderman, Koos; de Jonge, Wouter; Snoek, Susanne; Bolhuis, Karen; van der Zanden, Esmerij; The, Frans; Bennink, Roel; Boeckxstaens, Guy

    2011-01-01

    Postoperative ileus is characterized by delayed gastrointestinal (GI) transit and is a major determinant of recovery after colorectal surgery. Both laparoscopic surgery and fast-track multimodal perioperative care have been reported to improve clinical recovery. However, objective measures

  17. Does BMI influence hospital stay and morbidity after fast-track hip and knee arthroplasty?

    DEFF Research Database (Denmark)

    Husted, Henrik; Jørgensen, Christoffer C; Gromov, Kirill

    2016-01-01

    Background and purpose - Body mass index (BMI) outside the normal range possibly affects the perioperative morbidity and mortality following total hip arthroplasty (THA) and total knee arthroplasty (TKA) in traditional care programs. We determined perioperative morbidity and mortality in such pat......Background and purpose - Body mass index (BMI) outside the normal range possibly affects the perioperative morbidity and mortality following total hip arthroplasty (THA) and total knee arthroplasty (TKA) in traditional care programs. We determined perioperative morbidity and mortality...... in such patients who were operated with the fast-track methodology and compared the levels with those in patients with normal BMI. Patients and methods - This was a prospective observational study involving 13,730 procedures (7,194 THA and 6,536 TKA operations) performed in a standardized fast-track setting....... Complete 90-day follow-up was achieved using national registries and review of medical records. Patients were grouped according to BMI as being underweight, of normal weight, overweight, obese, very obese, and morbidly obese. Results - Median length of stay (LOS) was 2 (IQR: 2-3) days in all BMI groups. 30...

  18. A process model for design team communication within fast-track building projects using project websites

    NARCIS (Netherlands)

    Otter, den A.F.H.J.; Reymen, I.M.M.J.

    2008-01-01

    The factor time within building projects is on high pressure because of the increasing need for faster delivery of buildings. Within fast track, complex building projects the design process is an important key. Through case analyses offart-hack design processes it became obvious that process and

  19. Time course and reasons for 90-day mortality in fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, C C; Kehlet, H

    2017-01-01

    : Prospective observational study in 13,775 consecutive THA/TKAs with similar fast-track protocols and a median length of stay of 2 days. Complete 90-days follow-up through national registries, followed by review of medical records and death certificates. Relation between mortality and surgically induced organ...

  20. Spouses’ involvement in older patients’ fast-track programmes during total hip replacement using case management intervention. A study protocol of the SICAM-trial

    DEFF Research Database (Denmark)

    Berthelsen, Connie Bøttcher; Kristensson, Jimmie

    2015-01-01

    Aim To present the protocol of a two-group quasi-experimental study of spouses’ involvement through case management (The SICAM-trial) in older patients’ fast-track programmes during total hip replacement. Background Patients in fast-track programmes are required to take an active part in their tr......Aim To present the protocol of a two-group quasi-experimental study of spouses’ involvement through case management (The SICAM-trial) in older patients’ fast-track programmes during total hip replacement. Background Patients in fast-track programmes are required to take an active part...... in their treatment and rehabilitation. Spouses of older patients can often provide valued practical and emotional support, reducing stress, pain and length of stay – yet they are seldom invited to participate in a supporting role. Design A two-group quasi-experimental design with pre-test and repeated post...... and subsequently include the intervention group to avoid contamination of the control group. A case manager will be recruited to perform the case management intervention. Data will be collected from both groups at baseline, 2 weeks and 3 months after surgery. Outcome measures for patients include: functional...

  1. New Medical-School Programs Put Students on a Fast Track to the White Coat

    Science.gov (United States)

    Mangan, Katherine

    2009-01-01

    California's lieutenant governor has proposed a fast-track medical school that would shave three years off the training needed to become a physician. It is not the first time such an idea has been offered. The proposal, for a hoped-for medical school at the University of California at Merced, struck some medical educators as both unrealistic and…

  2. Implementation and Performance of FPGA based track fitting for the Atlas Fast TracKer

    CERN Document Server

    Zou, Rui; The ATLAS collaboration

    2018-01-01

    The Fast TracKer (FTK) within the ATLAS trigger system provides global track reconstruction for all events passing the ATLAS Level 1 trigger by dividing the detector into parallel processing pipelines that implement pattern matching in custom integrated circuits and data routing, reduction, and parameter extraction in FPGAs. In this presentation we will describe the implementation of a critical component of the system which does partial track fitting using a method based on a principal component analysis at a rate of greater than 1 fit per 10 ps, system-wide, to reduce the output of the pattern matching. Firmware design, timing performance and preliminary results will be discussed.

  3. Fast TPC Online Tracking on GPUs and Asynchronous Data Processing in the ALICE HLT to facilitate Online Calibration

    International Nuclear Information System (INIS)

    Rohr, David; Gorbunov, Sergey; Krzewicki, Mikolaj; Breitner, Timo; Kretz, Matthias; Lindenstruth, Volker

    2015-01-01

    ALICE (A Large Heavy Ion Experiment) is one of the four major experiments at the Large Hadron Collider (LHC) at CERN, which is today the most powerful particle accelerator worldwide. The High Level Trigger (HLT) is an online compute farm of about 200 nodes, which reconstructs events measured by the ALICE detector in real-time. The HLT uses a custom online data-transport framework to distribute data and workload among the compute nodes.ALICE employs several calibration-sensitive subdetectors, e.g. the TPC (Time Projection Chamber). For a precise reconstruction, the HLT has to perform the calibration online. Online- calibration can make certain Offline calibration steps obsolete and can thus speed up Offline analysis. Looking forward to ALICE Run III starting in 2020, online calibration becomes a necessity.The main detector used for track reconstruction is the TPC. Reconstructing the trajectories in the TPC is the most compute-intense step during event reconstruction. Therefore, a fast tracking implementation is of great importance. Reconstructed TPC tracks build the basis for the calibration making a fast online-tracking mandatory.We present several components developed for the ALICE High Level Trigger to perform fast event reconstruction and to provide features required for online calibration.As first topic, we present our TPC tracker, which employs GPUs to speed up the processing, and which bases on a Cellular Automaton and on the Kalman filter. Our TPC tracking algorithm has been successfully used in 2011 and 2012 in the lead-lead and the proton-lead runs. We have improved it to leverage features of newer GPUs and we have ported it to support OpenCL, CUDA, and CPUs with a single common source code. This makes us vendor independent.As second topic, we present framework extensions required for online calibration. The extensions, however, are generic and can be used for other purposes as well. We have extended the framework to support asynchronous compute chains

  4. Development and Integration of the CT-PPS Fast Simulation in the CMS Software

    CERN Document Server

    Fonseca De Souza, Sandro

    2017-01-01

    CT-PPS (CMS-TOTEM Precision Proton Spectrometer) is a joint project of the CMS and TOTEM collaborations with the goal of studying central exclusive production (CEP) in proton-proton collisions. A simplified simulation and reconstruction code for CT-PPS has been implemented in the CMS fast simulation package FastSim. Protons scattered at very low polar angles are propagated along the LHC beamlines from the generated vertex to the detectors by means of the beam transport package Hector. The reconstructed proton tracks are obtained from the simulated hits in the tracking detectors and are used to determine the proton kinematics at the vertex. The timing information is added to the tracks.

  5. Measured and calculated absorptance of tracks of fast heavy ions in Ilford G5 nuclear emulsion

    International Nuclear Information System (INIS)

    Jensen, M.; Mathiesen, O.

    1975-04-01

    A modified form of the delta-ray theory of track formation developed by Katz and coworkers has been used to calculate the absorptance of tracks of fast heavy ions in Ilford G5 nuclear emulsion. The theoretical data have been compared with results of different photometrical investigations reported in the literature. In most cases the theoretical predictions are found to be in good agreement with experiments. This suggests that the theory can be used in the planning and execution of future experiments, i.e. to optimize the geometry of the photometer and to obtain an absolute charge calibration of the detector. It is shown that the basic photometrical properties of an emulsion stack can be described by a single quantity which can be determined from measurements. Knowing this quantity it is possible to predict the response of the emulsion stack for different types of photometers. The practical limits of the use of the modified theory at high and low levels of energy dose are discussed. (Auth.)

  6. Measured and calculated absorptance of tracks of fast heavy ions in Ilford G5 nuclear emulsion

    International Nuclear Information System (INIS)

    Jensen, M.; Mathiesen, O.

    1976-01-01

    A modified form of the delta-ray theory of track formation developed by Katz and coworkers has been used to calculate the absorptance of tracks of fast heavy ions in Ilford G5 nuclear emulsion. The theoretical data have been compared with results of different photometrical investigations reported in the literature. In most cases the theoretical predictions are found to be in good agreement with experiments. This suggests that the theory can be used in the planning and execution of future experiments, i.e. to optimize the geometry of the photometer and to obtain an absolute charge calibration of the detector. It is shown that the basic photometrical properties of an emulsion stack can be described by a single quantity which can be determined from measurements. Knowing this quantity it is possible to predict the response of the detector system, for different types of photometers. The practical limits of the use of the modified theory at high and low levels of energy dose are discussed. (Auth.)

  7. Fast Filter Central Drift Chamber Program. MAC Note 404

    International Nuclear Information System (INIS)

    Ford, W.T.

    1979-01-01

    A fast filter of the central detector tracking program was developed and tested. The search for tracks is conducted as in the full linking program - from the outermost layer hit to the next layer in. Any hit is accepted within a road centered which is large enough to allow for stero displacement and any curvature. With the fast filter, this is continued to the innermost layer, with five or more hits accepted as a track

  8. Real-time tracking and fast retrieval of persons in multiple surveillance cameras of a shopping mall

    Science.gov (United States)

    Bouma, Henri; Baan, Jan; Landsmeer, Sander; Kruszynski, Chris; van Antwerpen, Gert; Dijk, Judith

    2013-05-01

    The capability to track individuals in CCTV cameras is important for e.g. surveillance applications at large areas such as train stations, airports and shopping centers. However, it is laborious to track and trace people over multiple cameras. In this paper, we present a system for real-time tracking and fast interactive retrieval of persons in video streams from multiple static surveillance cameras. This system is demonstrated in a shopping mall, where the cameras are positioned without overlapping fields-of-view and have different lighting conditions. The results show that the system allows an operator to find the origin or destination of a person more efficiently. The misses are reduced with 37%, which is a significant improvement.

  9. The Fleet Application for Scheduling and Tracking (FAST) Management Website

    Science.gov (United States)

    Marrero-Perez, Radames J.

    2014-01-01

    The FAST application was designed to replace the paper and pen method of checking out and checking in GSA Vehicles at KSC. By innovating from a paper and pen based checkout system to a fully digital one, not only the resources wasted by printing the checkout forms have been reduced, but it also reduces significantly the time that users and fleet managers need to interact with the system as well as improving the record accuracy for each vehicle. The vehicle information is pulled from a centralized database server in the SPSDL. In an attempt to add a new feature to the FAST application, the author of this report (alongside the FAST developers) has been designing and developing the FAST Management Website. The GSA fleet managers had to rely on the FAST developers in order to add new vehicles, edit vehicles and previous transactions, or for generating vehicles reports. By providing an easy-to-use FAST Management Website portal, the GSA fleet managers are now able to easily move vehicles, edit records, and print reports.

  10. Fast neutron detection using solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Vilela, E.C.

    1990-01-01

    CR-39 and Makrofol-E solid state nuclear track detectors were studied aiming their application to fast neutron detection. Optimum etching conditions of those two kinds of materials were determined the followings - the Makrofol-E detector is electrochemically etched in a PEW solution (15% KOH, 40% ethilic alcohol and 45% water) for 2 h., with an applied electric field strength of 30 kV/cm (r/m/s/) and frequency of 2 kHz, at room temperature; - the CR-39 detector is chemically pre-etched during 1 h in a 20% (w/v) NaOH solution at 70 sup(0)C, followed by 13 h electrochemical etch using the same solution at room temperature and an electric field strength of 30 kV/cm (r.m.s.) and frequency of 2 kHz.(E.G.)

  11. Online tracking applications of the general purpose EDRO Board

    CERN Document Server

    Annovi, A; The ATLAS collaboration; Cervini, F; Crescioli, F; Fabbri, L; Franchini, M; Giannetti, P; Giannuzzi, F; Giorgi, F; Magalotti, D; Piendibene, M; Sbarra, C; Valentinetti, S; Mauro, V; Zoccoli, A

    2012-01-01

    The capability to perform extremely fast track reconstruction online is becoming more and more important for the LHC upgrade as well as the next generation of HEP experiments, where the expected instantaneous luminosities (in excess of 10^34 /cm2/s) and the very low signal/background ratio ask for fast and clean identification of the main characteristics of interesting events. The Slim5 R&D project studied different aspects of fast and high-precision tracking in dedicated hardware: data-push silicon sensors, high bandwidth DAQ systems and Associative Memories (AM) for fast track identification. The central element of the development system is a high traffic board, called EDRO, capable of collecting and processing digital data with an input rate of 16 Gbps. The input hits, suitably formatted or clusterized, are sent to an AM board sending back candidate tracks, which are identified at a rate of 40 MHz. The EDRO board is then able to deliver triggers and formatted events for further processing. The EDRO-AM ...

  12. Bellcord: a multilevel fast preprocessor for 1024 ECL channels

    International Nuclear Information System (INIS)

    Kerns, C.R.

    1978-01-01

    To provide a fast decision trigger on multiple tracks passing through multiwire proportional chambers, a high-speed (arriving at an answer in 60 ns) track counting system was developed at Fermilab. The circuit is capable of selecting the track multiplicities utilizing a coaxial cable ''Bus'' (the Bellcord) on which fast pulses are summed. Up to 16 Bellcord coax cables, each having 64 inputs, are fanned into a central ''Hub'' processor where the trigger level decision is made. 7 figures

  13. Preoperative prediction of potentially preventable morbidity after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer C; Petersen, Morten Aa; Kehlet, Henrik

    2016-01-01

    . DESIGN: Prospective observational study. SETTING: Elective primary unilateral total hip and knee arthroplasty with prospectively collected preoperative patient characteristics; similar standardised fast-track protocols; evaluation of complications through discharge and medical records; and complete 90...... days follow-up through nationwide databases. PARTICIPANTS: 8373 consecutive unselected total hip arthroplasty (THA) and knee arthroplasty from January 2010 to November 2012. RESULTS: There were 557 procedures (6.4%) followed by potentially preventable complications resulting in hospitalisation >4 days...

  14. The use of a break-even analysis: financial analysis of a fast-track program.

    Science.gov (United States)

    Saywell, R M; Cordell, W H; Nyhuis, A W; Giles, B K; Culler, S D; Woods, J R; Chu, D K; McKinzie, J P; Rodman, G H

    1995-08-01

    To calculate the financial break-even point and illustrate how changes in third-party reimbursement and eligibility could affect a program's fiscal standing. Demographic, clinical, and financial data were collected retrospectively for 446 patients treated in a fast-track program during June 1993. The fast-track program is located within the confines of the emergency medicine and trauma center at a 1,050-bed tertiary care Midwestern teaching hospital and provides urgent treatment to minimally ill patients. A financial break-even analysis was performed to determine the point where the program generated enough revenue to cover its total variable and fixed costs, both direct and indirect. Given the relatively low average collection rate (62%) and high percentage of uninsured patients (31%), the analysis showed that the program's revenues covered its direct costs but not all of the indirect costs. Examining collection rates or payer class mix without examining both costs and revenues may lead to an erroneous conclusion about a program's fiscal viability. Sensitivity analysis also shows that relatively small changes in third-party coverage or eligibility (income) requirements can have a large impact on the program's financial solvency and break-even volumes.

  15. Improving the quality of pretreatment staging in patients with esophageal carcinoma - a fast track study

    Energy Technology Data Exchange (ETDEWEB)

    Didden, Paul; Spaander, Manon C. W.; Kuipers, Ernst J.; Bruno, Marco J. (Department of Gastroenterology and Hepatology, Erasmus University Medical Center, Rotterdam (Netherlands)), E-mail: v.spaander@erasmusmc.nl; Wijnhoven, Bas P. L. (Department of Surgery, Erasmus University Medical Center, Rotterdam (Netherlands))

    2012-03-15

    Background: Current guidelines for esophageal cancer recommend series of diagnostic investigations to determine pretreatment TNM stage. When investigations are done sequentially, diagnostic work-up time may be prolonged considerably. Aim of the study was to determine the feasibility and efficacy of a fast track staging strategy within five days after the first consultation. Material and methods: Between 2007 and 2010 all patients presenting with esophageal cancer at the Department of Gastroenterology in a tertiary referral center were prospectively analyzed. At Day 1 all patients underwent computed tomography (CT), endoscopic ultrasound (EUS) and ultrasonography of the neck (United States). Results and treatment implications were discussed within a multidisciplinary meeting. This fast track strategy was considered completed successfully if pre-treatment TNM classification was achieved and therapy was proposed to the patient at the outpatient clinic at Day five. In those cases where staging period time was prolonged, the number and type of additional tests were documented including the ensuing time delay. Results: In 111 patients CT, EUS and US were performed in 100%, 88.3% and 97.3% respectively. A final TNM stage and treatment proposal was reached at Day 5 in 60% of the patients. Additional tests were diverse and mainly used to prove local irresectability or presence of distant metastasis. Multivariate analysis identified presence of lymphadenopathy (HR 0.25 p 0.03) and metastasis (HR 0.27 p = 0.03) as significant predictors of not completing the staging period within five days. In 18% of patients overuse of at least one test occurred, most commonly because CT already revealed distant metastasis. Conclusion: Employment of a fast track five day staging strategy in patients with esophageal carcinoma is feasible. Definite TNM stage and treatment proposal can be achieved in 60% of cases, but comes at the expense of test overuse in about one fifth of patients

  16. Mass tracking and material accounting in the integral fast reactor (IFR)

    International Nuclear Information System (INIS)

    Orechwa, Y.; Adams, C.H.; White, A.M.

    1991-01-01

    This paper reports on the Integral Fast Reactor (IFR) which is a generic advanced liquid metal cooled reactor concept being developed at Argonne National Laboratory. There are a number of technical features of the IFR which contribute to its potential as a next-generation reactor. These are associated with large safety margins with regard to off-normal events involving the heat transport system, and the use of metallic fuel which makes possible the utilization of innovative fuel cycle processes. The latter feature permits fuel cycle closure with compact, low-cost reprocessing facilities, collocated with the reactor plant. These primary features are being demonstrated in the facilities at ANL-West, utilizing Experimental Breeder Reactor II and the associated Fuel Cycle Facility (FCF) as an IFR prototype. The demonstration of this IFR prototype includes the design and implementation of the Mass-tracking System (MTG). In this system, data from the operations of the FCF, including weights and batch-process parameters, are collected and maintained by the MTG running on distributed workstations

  17. Hardware realization of a fast neural network algorithm for real-time tracking in HEP experiments

    International Nuclear Information System (INIS)

    Leimgruber, F.R.; Pavlopoulos, P.; Steinacher, M.; Tauscher, L.; Vlachos, S.; Wendler, H.

    1995-01-01

    A fast pattern recognition system for HEP experiments, based on artificial neural network algorithms (ANN), has been realized with standard electronics. The multiplicity and location of tracks in an event are determined in less than 75 ns. Hardware modules of this first level trigger were extensively tested for performance and reliability with data from the CPLEAR experiment. (orig.)

  18. Relatives in older patients' fast-track treatment programme during total hip or knee replacement. A grounded theory study

    DEFF Research Database (Denmark)

    Berthelsen, Connie Bøttcher

    and considerate support in concern for the patients; Substituting mode, with practical and cognitive support; and Adapting mode, by trying to fit in with the patients’ and health professionals’ requirements. Study II: 16 patients aged 70 to 94 were included and data was collected through 15 non......The aim of this Ph.D.-dissertation was to generate grounded theories of relatives, patients, and health professionals’ pattern of behaviour, respectively, in relation to the relatives of older patients’ fast-track treatment programmes during total hip or knee replacement. The dissertation includes...... to the older patients’ self-determination of being autonomous and how they adapt and are perceived in the health professionals’ environment. This may be useful to the health professionals in orthopaedic fast-track treatment programmes and their future collaboration with older patients and their relatives....

  19. Role of preoperative anemia for risk of transfusion and postoperative morbidity in fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jans, Øivind; Jørgensen, Christoffer; Kehlet, Henrik

    2014-01-01

    BACKGROUND: Preoperative anemia has been associated with increased risk of allogeneic blood transfusion and postoperative morbidity and mortality. The prevalence of preoperative anemia and its association with postoperative outcomes has not previously been reported in relation to fast......-track elective total hip arthroplasty (THA) and total knee arthroplasty (TKA). We aimed to evaluate the prevalence of preoperative anemia in elective fast-track THA and TKA and its association with risk of perioperative transfusion, prolonged length of hospital stay (LOS), and postoperative readmission. STUDY...... national databases and patient charts. Adjusted risk estimates for transfusion, prolonged LOS, and all-cause readmission according to preoperative anemia status were obtained by multivariate logistic regression. RESULTS: A total of 5.165 THA or TKA procedures were included with a mean patient age of 67...

  20. Nursing in fast-track total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Specht, Kirsten; Kjaersgaard-Andersen, Per; Kehlet, Henrik

    2015-01-01

    must still focus on the individual patient. Nurses need to have enough education to manage the complex tasks and increased responsibility. To prevent undesirable outcomes in the future, there is a need to pay attention to the nursing quality in balance with the nursing budget. It may, therefore......AIM: To describe the increased activity in total hip arthroplasty (THA) and total knee arthroplasty (TKA) from 2002 to 2012 in a single orthopaedic department, the organisation of fast-track and its consequences for nursing care. METHODS: Retrospective, descriptive design. Data collection; from...... gained tasks from surgeons and physiotherapists and thus gained more responsibility, for example, for pain management and mobilisation. Staffing levels in the ward in 2002 and 2012 were almost unchanged; 16.0 and 15.8 respectively. Nurses were undertaking more complicated tasks. CONCLUSION: Nursing care...

  1. Sleep disturbances after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Krenk, L; Jennum, P; Kehlet, H

    2012-01-01

    BACKGROUND: /st>Major surgery is followed by pronounced sleep disturbances after traditional perioperative care potentially leading to prolonged recovery. The aim was to evaluate the rapid eye movement (REM) sleep duration and sleep architecture before and after fast-track hip and knee replacement......, and on the fourth postoperative night at home. Sleep staging was performed according to the American Academy of Sleep Medicine manual. Opioid use, pain, and inflammatory response (C-reactive protein) were also evaluated. RESULTS: /st>The mean LOS was 1.5 (1-2) days. The mean REM sleep time decreased from a mean...... on the fourth postoperative night. There was no association between opioid use, pain scores, and inflammatory response with a disturbed sleep pattern. CONCLUSIONS: /st>Despite ultra-short LOS and provision of spinal anaesthesia with multimodal opioid-sparing analgesia, REM sleep was almost eliminated...

  2. A "package solution" fast track program can reduce the diagnostic waiting time in head and neck cancer

    DEFF Research Database (Denmark)

    Sørensen, Jesper Roed; Johansen, Jørgen; Gano, Lars

    2014-01-01

    and Neck Surgery during three comparable time intervals 2006-2007, 2007-2008, and 2011-2012 (groups 1-3) were investigated. We recorded the time from patient referral, to first consultation and final diagnosis. The first interval was before initiation of the "package solution", the second just after......In 2007, a fast track program for patients with suspicion of head and neck cancer (HNC) was introduced in Denmark to reduce unnecessary waiting time. The program was based on so called "package solutions" including pre-booked slots for outpatient evaluation, imaging, and diagnostic surgical...... procedures. The purpose of this study is to present a model for fast track handling of patients suspicious of cancer in the head and neck region and to evaluate the effect of implementation on the diagnostic work up time. Patients with suspicion of HNC referred to the same university department of ENT Head...

  3. Physiotherapy Exercise After Fast-Track Total Hip and Knee Arthroplasty: Time for Reconsideration?

    DEFF Research Database (Denmark)

    Bandholm, Thomas; Kehlet, Henrik

    2012-01-01

    Bandholm T, Kehlet H. Physiotherapy exercise after fast-track total hip and knee arthroplasty: time for reconsideration? Major surgery, including total hip arthroplasty (THA) and total knee arthroplasty (TKA), is followed by a convalescence period, during which the loss of muscle strength......-track methodology or enhanced recovery programs. It is the nature of this methodology to systematically and scientifically optimize all perioperative care components, with the overall goal of enhancing recovery. This is also the case for the care component "physiotherapy exercise" after THA and TKA. The 2 latest...... meta-analyses on the effectiveness of physiotherapy exercise after THA and TKA generally conclude that physiotherapy exercise after THA and TKA either does not work or is not very effective. The reason for this may be that the "pill" of physiotherapy exercise typically offered after THA and TKA does...

  4. Ultra-Fast Tracking Power Supply with 4th order Output Filter and Fixed-Frequency Hysteretic Control

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2008-01-01

    A practical solution is presented for the design of a non-isolated DC/DC power converter with very low output ripple voltage and very fast output voltage step response. The converter is intended for use as an envelope tracking power supply for an RFPA (Radio Frequency Power Amplifier) in a Tetra2...

  5. Concept of fast-track surgery and its application in perioperative period of hepatectomy for liver cancer

    Directory of Open Access Journals (Sweden)

    HAN Wei

    2016-10-01

    Full Text Available Fast-track surgery (FTS is widely used in the field of hepatopancreatobiliary surgery and has achieved a great success in the perioperative period of liver cancer. It has been recognized by clinical doctors and patients. This article introduces the concept of FTS, reviews its development, summarizes the detailed measures of FTS in the perioperative period of liver cancer and long-term application experience of FTS, and analyzes the current status of its clinical application. It is pointed out that when applied in the perioperative period of hepatectomy for liver cancer, FTS can reduce stress, lower the incidence of postoperative complications, shorten the length of hospital stay, and bring true benefits to patients.

  6. Predictors of length of stay and patient satisfaction after hip and knee replacement surgery: fast-track experience in 712 patients

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte; Jacobsen, Steffen

    2008-01-01

    BACKGROUND AND PURPOSE: Very few studies have focused on patient characteristics that influence length of stay (LOS) in fast-track total hip (THR) and knee arthroplasty (TKR). The aim of this prospective study was to identify patient characteristics associated with LOS and patient satisfaction...... aids, pre- and postoperative hemoglobin levels, the need for blood transfusion, ASA score, and time between surgery and mobilization, were all found to influence postoperative outcome in general, and LOS and patient satisfaction in particular. INTERPRETATION: We identified several patient...... characteristics that influence postoperative outcome, LOS, and patient satisfaction in our series of consecutive fast-track joint replacement patients, enabling further attention to be paid to certain aspects of surgery and rehabilitation....

  7. Readmission rates after a planned hospital stay of 2 versus 3 days in fast-track colonic surgery

    DEFF Research Database (Denmark)

    Andersen, Jens; Hjort-Jakobsen, Dorthe; Christiansen, P. S.

    2007-01-01

    BACKGROUND: Initial programmes of fast-track open colonic surgery with a planned 2-day postoperative hospital stay have had a high readmission rate (about 20 per cent). The aim of this large, consecutive series was to compare readmission rates after a fast-track open colonic surgery programme...... from August 2004. All patients were examined 8 and 30 days after surgery. RESULTS: Readmission rates fell from 20.1 per cent in 408 patients with a planned 2-day hospital stay (period 1) to 11.3 per cent in 133 patients with a planned 3-day hospital stay (period 2) (P ... hospital stay was 2 and 3 days, median stay after readmission was 5 and 5.5 days, and median (mean) total stay was 3 (5.6) and 3 (5.7) days in periods 1 and 2 respectively. The readmission rate in period 2 was lower because there were fewer readmissions for short-term observation or social reasons...

  8. Fast-track aquifer characterization and bioremediation of groundwater

    International Nuclear Information System (INIS)

    Owen, S.B.; Erskine, J.A.; Adkisson, C.

    1995-01-01

    A short duration step-drawdown pumping test has been used to characterize a highly permeable aquifer contaminated with petroleum hydrocarbons in support of an in situ, closed loop extraction and reinjection bioremediation system for groundwater. The short-term pumping test produces a manageable quantity of contaminated groundwater while yielding a range of values for transmissivity and specific yield parameters. This range of aquifer coefficients is used in an analytical model to estimate a range of groundwater extraction rates that provide a suitable radius of influence for the extraction and reinjection system. A multi-enzyme complex catalyzed bioremediation process has been used to aerobically degrade petroleum hydrocarbons. Enzymes, amino acids, and biosurfactants are supplied to the extracted groundwater to significantly speed up the degradation by naturally occurring bacteria. During the process, amino acids promote the rapid growth of the microbial population while enzymes and bacteria attach to hydrocarbons forming a transformation state complex that degrades to fatty acids, carbon dioxide, and water. This paper presents a case study of a fast-track bioremediation using pumping test data, analytical modeling, and an enzyme technology

  9. ATLAS FTK: The Fast Tracker

    CERN Document Server

    T, Iizawa; The ATLAS collaboration

    2014-01-01

    The Fast TracKer (FTK) will perform global track reconstruction after each Level-1 trigger accept to enable the software-based High Level Trigger to have early access to tracking information. FTK is a dedicated processor based on a mixture of advanced technologies. Modern, powerful Field Programmable Gate Arrays (FPGAs) form an important part of the system architecture, and the large level of computing power required for pattern recognition is provided by incorporating standard-cell ASICs named Associative Memory (AM). FTK provides global track reconstruction in the full inner silicon detector in approximately 100 microseconds with resolution comparable to the offline algorithms. It allows a fast and precise detection of the primary and secondary vertex information. The track and vertex information is then used by the High Level Trigger algorithms, allowing highly improved trigger performance for the important signatures such as b-jets. In this paper, the architecture and the hardware development status of FT...

  10. FATRAS - the ATLAS Fast Track Simulation project

    NARCIS (Netherlands)

    Mechnich, J.

    2011-01-01

    The Monte Carlo simulation of the detector response is an integral component of any analysis performed with data from the LHC experiments. As these simulated data sets must be both large and precise, their production is a CPU-intensive task. ATLAS has developed full and fast detector simulation

  11. Assessment of fast and thermal neutron ambient dose equivalents around the KFUPM neutron source storage area using nuclear track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Fazal-ur-Rehman [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)]. E-mail: fazalr@kfupm.edu.sa; Al-Jarallah, M.I. [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Abu-Jarad, F. [Radiation Protection Unit, Environmental Protection Department, Saudi Aramco, P. O. Box 13027, Dhahran 31311 (Saudi Arabia); Qureshi, M.A. [Center for Applied Physical Sciences, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2005-11-15

    A set of five {sup 241}Am-Be neutron sources are utilized in research and teaching at King Fahd University of Petroleum and Minerals (KFUPM). Three of these sources have an activity of 16Ci each and the other two are of 5Ci each. A well-shielded storage area was designed for these sources. The aim of the study is to check the effectiveness of shielding of the KFUPM neutron source storage area. Poly allyl diglycol carbonate (PADC) Nuclear track detectors (NTDs) based fast and thermal neutron area passive dosimeters have been utilized side by side for 33 days to assess accumulated low ambient dose equivalents of fast and thermal neutrons at 30 different locations around the source storage area and adjacent rooms. Fast neutron measurements have been carried out using bare NTDs, which register fast neutrons through recoils of protons, in the detector material. NTDs were mounted with lithium tetra borate (Li{sub 2}B{sub 4}O{sub 7}) converters on their surfaces for thermal neutron detection via B10(n,{alpha})Li6 and Li6(n,{alpha})H3 nuclear reactions. The calibration factors of NTD both for fast and thermal neutron area passive dosimeters were determined using thermoluminescent dosimeters (TLD) with and without a polyethylene moderator. The calibration factors for fast and thermal neutron area passive dosimeters were found to be 1.33 proton tracks cm{sup -2}{mu}Sv{sup -1} and 31.5 alpha tracks cm{sup -2}{mu}Sv{sup -1}, respectively. The results show variations of accumulated dose with the locations around the storage area. The fast neutron dose equivalents rates varied from as low as 182nSvh{sup -1} up to 10.4{mu}Svh{sup -1} whereas those for thermal neutron ranged from as low as 7nSvh{sup -1} up to 9.3{mu}Svh{sup -1}. The study indicates that the area passive neutron dosimeter was able to detect dose rates as low as 7 and 182nSvh{sup -1} from accumulated dose for thermal and fast neutrons, respectively, which were not possible to detect with the available active neutron

  12. The design and simulated performance of a fast Level 1 track trigger for the ATLAS High Luminosity Upgrade

    CERN Document Server

    Martensson, Mikael; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment at the High Luminosity LHC will face a fivefold increase in the number of interactions per bunch crossing relative to the ongoing Run 2. This will require a proportional improvement in rejection power at the earliest levels of the detector trigger system, while preserving good signal efficiency. One critical aspect of this improvement will be the implementation of precise track reconstruction, through which sharper trigger turn-on curves can be achieved, and b-tagging and tau-tagging techniques can in principle be implemented. The challenge of such a project comes in the development of a fast, custom electronic device integrated in the hardware based first trigger level of the experiment. This article will discuss the requirements, architecture and projected performance of the system in terms of tracking, timing and physics, based on detailed simulations. Studies are carried out using data from the strip subsystem only or both strip and pixel subsystems.

  13. The design and simulated performance of a fast Level 1 track trigger for the ATLAS High Luminosity Upgrade

    CERN Document Server

    Martensson, Mikael; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment at the high-luminosity LHC will face a five-fold increase in the number of interactions per collision relative to the ongoing Run 2. This will require a proportional improvement in rejection power at the earliest levels of the detector trigger system, while preserving good signal efficiency. One critical aspect of this improvement will be the implementation of precise track reconstruction, through which sharper trigger turn-on curves can be achieved, and b-tagging and tau-tagging techniques can in principle be implemented. The challenge of such a project comes in the development of a fast, custom electronic device integrated in the hardware-based first trigger level of the experiment, with repercussions propagating as far as the detector read-out philosophy. This talk will discuss the requirements, architecture and projected performance of the system in terms of tracking, timing and physics, based on detailed simulations. Studies are carried out comparing two detector geometries and using...

  14. Fall-related admissions after fast-track total hip and knee arthroplasty - cause of concern or consequence of success?

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer Calov; Kehlet, Henrik; Hip, Lundbeck Foundation Centre for Fast-track

    2013-01-01

    Total hip (THA) and knee arthroplasty (TKA) are common procedures in elderly persons, who are at potential increased risk of postoperative fall due to loss of muscle strength and impaired balance. Fast-track surgery with early mobilization and opioid-sparing analgesia have improved outcomes after...

  15. Fast track land reform, tenure security and investments in soil conservation: Micro-evidence from Mazowe district in Zimbabwe

    NARCIS (Netherlands)

    Zikhali, P.

    2010-01-01

    The government of Zimbabwe launched the Fast Track Land Reform Programme (FTLRP) in 2000 as part of its ongoing land reform and resettlement programme which aims to address a racially skewed land distribution. Its goal has been to accelerate both land acquisition and redistribution, targeting at

  16. Object tracking on mobile devices using binary descriptors

    Science.gov (United States)

    Savakis, Andreas; Quraishi, Mohammad Faiz; Minnehan, Breton

    2015-03-01

    With the growing ubiquity of mobile devices, advanced applications are relying on computer vision techniques to provide novel experiences for users. Currently, few tracking approaches take into consideration the resource constraints on mobile devices. Designing efficient tracking algorithms and optimizing performance for mobile devices can result in better and more efficient tracking for applications, such as augmented reality. In this paper, we use binary descriptors, including Fast Retina Keypoint (FREAK), Oriented FAST and Rotated BRIEF (ORB), Binary Robust Independent Features (BRIEF), and Binary Robust Invariant Scalable Keypoints (BRISK) to obtain real time tracking performance on mobile devices. We consider both Google's Android and Apple's iOS operating systems to implement our tracking approach. The Android implementation is done using Android's Native Development Kit (NDK), which gives the performance benefits of using native code as well as access to legacy libraries. The iOS implementation was created using both the native Objective-C and the C++ programing languages. We also introduce simplified versions of the BRIEF and BRISK descriptors that improve processing speed without compromising tracking accuracy.

  17. Fast particle tracking with wake fields

    Energy Technology Data Exchange (ETDEWEB)

    Dohlus, M.; Floettmann, K.; Henning, C.

    2012-01-15

    Tracking calculations of charged particles in electromagnetic fields require in principle the simultaneous solution of the equation of motion and of Maxwell's equations. In many tracking codes a simpler and more efficient approach is used: external fields like that of the accelerating structures are provided as field maps, generated in separate computations and for the calculation of self fields the model of a particle bunch in uniform motion is used. We describe how an externally computed wake function can be approximated by a table of Taylor coefficients and how the wake field kick can be calculated for the particle distribution in a tracking calculation. The integrated kick, representing the effect of a distributed structure, is applied at a discrete time. As an example, we use our approach to calculate the emittance growth of a bunch in an undulator beam pipe due to resistive wall wake field effects. (orig.)

  18. Multiple feature fusion via covariance matrix for visual tracking

    Science.gov (United States)

    Jin, Zefenfen; Hou, Zhiqiang; Yu, Wangsheng; Wang, Xin; Sun, Hui

    2018-04-01

    Aiming at the problem of complicated dynamic scenes in visual target tracking, a multi-feature fusion tracking algorithm based on covariance matrix is proposed to improve the robustness of the tracking algorithm. In the frame-work of quantum genetic algorithm, this paper uses the region covariance descriptor to fuse the color, edge and texture features. It also uses a fast covariance intersection algorithm to update the model. The low dimension of region covariance descriptor, the fast convergence speed and strong global optimization ability of quantum genetic algorithm, and the fast computation of fast covariance intersection algorithm are used to improve the computational efficiency of fusion, matching, and updating process, so that the algorithm achieves a fast and effective multi-feature fusion tracking. The experiments prove that the proposed algorithm can not only achieve fast and robust tracking but also effectively handle interference of occlusion, rotation, deformation, motion blur and so on.

  19. What Is Required to End the AIDS Epidemic as a Public Health Threat by 2030? The Cost and Impact of the Fast-Track Approach.

    Directory of Open Access Journals (Sweden)

    John Stover

    Full Text Available In 2011 a new Investment Framework was proposed that described how the scale-up of key HIV interventions could dramatically reduce new HIV infections and AIDS-related deaths in low and middle income countries by 2015. This framework included ambitious coverage goals for prevention and treatment services for 2015, resulting in a reduction of new HIV infections by more than half, in line with the goals of the declaration of the UN High Level Meeting in June 2011. However, the approach suggested a leveling in the number of new infections at about 1 million annually-far from the UNAIDS goal of ending AIDS by 2030. In response, UNAIDS has developed the Fast-Track approach that is intended to provide a roadmap to the actions required to achieve this goal. The Fast-Track approach is predicated on a rapid scale-up of focused, effective prevention and treatment services over the next 5 years and then maintaining a high level of programme implementation until 2030. Fast-Track aims to reduce new infections and AIDS-related deaths by 90% from 2010 to 2030 and proposes a set of biomedical, behavioral and enabling intervention targets for 2020 and 2030 to achieve that goal, including the rapid scale-up initiative for antiretroviral treatment known as 90-90-90. Compared to a counterfactual scenario of constant coverage for all services at early-2015 levels, the Fast-Track approach would avert 18 million HIV infections and 11 million deaths from 2016 to 2030 globally. This paper describes the analysis that produced these targets and the estimated resources needed to achieve them in low- and middle-income countries. It indicates that it is possible to achieve these goals with a significant push to achieve rapid scale-up of key interventions between now and 2020. The annual resources required from all sources would rise to US$7.4Bn in low-income countries, US$8.2Bn in lower middle-income countries and US$10.5Bn in upper-middle-income-countries by 2020 before

  20. Role of preoperative pain, muscle function, and activity level in discharge readiness after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Bandholm, Thomas; Lunn, Troels Haxholdt

    2014-01-01

    therefore investigated the role of preoperative pain and functional characteristics in discharge readiness and actual LOS in fast-track THA and TKA. METHODS: Before surgery, hip pain (THA) or knee pain (TKA), lower-extremity muscle power, functional performance, and physical activity were assessed...

  1. Fast Track to the Cloud: Design Patterns for 12-Factor Earth Sciences Applications

    Science.gov (United States)

    Pawloski, Andrew; McLaughlin, Brett; Lynnes, Christopher

    2016-01-01

    As expanding service offerings and decreasing prices make the cloud increasingly attractive to Earth Science applications, there are nontrivial practical considerations which can hinder its meaningful use. In this talk, we will discuss architectural recommendations and lessons learned while working on EOSDIS' cloud efforts, particularly the NASA-compliant General Application Platform (NGAP) and its associated applications. Prominent in our findings is the importance of 12-factor design patterns and the powerful "wins" they enable in the cloud. We will share our strategies for "fast-tracking" applications to the cloud --whether they be legacy, planned for the future, or somewhere in between.

  2. Early Progressive Strength Training to Enhance Recovery After Fast-Track Total Knee Arthroplasty

    DEFF Research Database (Denmark)

    Jakobsen, Thomas Linding; Kehlet, Henrik; Husted, Henrik

    2014-01-01

    different interventions: 7 weeks of supervised physical rehabilitation with PST (PST group) and without PST (CON group) commenced early after fast-track TKA. The primary outcome was the maximal distance walked in 6 minutes (6-minute walk test). Secondary outcomes were lower extremity strength and power......, knee joint effusion and range of motion, knee pain, and self-reported disability and quality of life. All outcome measures were assessed before TKA (baseline) and 4, 8, and 26 weeks after TKA. RESULTS: There was no statistically significant difference between the PST and CON groups in the change score...

  3. Online track reconstruction at hadron colliders

    International Nuclear Information System (INIS)

    Amerio, Silvia; Bettini, Marco; Nicoletto, Marino; Crescioli, Francesco; Bucciantonio, Martina; DELL'ORSO, Mauro; Piendibene, Marco; VOLPI, Guido; Annovi, Alberto; Catastini, Pierluigi; Giannetti, Paola; Lucchesi, Donatella

    2010-01-01

    Real time event reconstruction plays a fundamental role in High Energy Physics experiments. Reducing the rate of data to be saved on tape from millions to hundreds per second is critical. In order to increase the purity of the collected samples, rate reduction has to be coupled with the capability to simultaneously perform a first selection of the most interesting events. A fast and efficient online track reconstruction is important to effectively trigger on leptons and/or displaced tracks from b-quark decays. This talk will be an overview of online tracking techniques in different HEP environments: we will show how H1 experiment at HERA faced the challenges of online track reconstruction implementing pattern matching and track linking algorithms on CAMs and FPGAs in the Fast Track Processor (FTT). The pattern recognition technique is also at the basis of the Silicon Vertex Trigger (SVT) at the CDF experiment at Tevatron: coupled to a very fast fitting phase, SVT allows to trigger on displaced tracks, thus greatly increasing the efficiency for the hadronic B decay modes. A recent upgrade of the SVT track fitter, the Giga-fitter, can perform more than 1 fit/ns and further improves the CDF online trigger capabilities at high luminosity. At SLHC, where luminosities will be 2 orders of magnitude greater than Tevatron, online tracking will be much more challenging: we will describe CMS future plans for a Level-1 track trigger and the Fast Tracker (FTK) processor at the ATLAS experiment, based on the Giga-fitter architecture and designed to provide high quality tracks reconstructed over the entire detector in time for a Level-2 trigger decision.luminosity. At SLHC, where luminosities will be 2 orders of magnitude greater than Tevatron, online tracking will be much more challenging: we will describe CMS future plans for a Level-1 track trigger and the Fast Tracker (FTK) processor at the Atlas experiment, based on the Giga-fitter architecture and designed to provide high

  4. Nurse Practitioners' attitude to nutritional challenges dealing with the patients' nutritional needs and ability to care for themselves in a fast track program

    DEFF Research Database (Denmark)

    Graarup, Jytte; Pedersen, Preben Ulrich; Bjerrum, Merete

    2014-01-01

    Background: Nutrition plays an important role to the success of fast track programs, but under nutrition are still reported. Nutritional care seems to be a low priority among nurses even though it is well-known that insufficient nutrition has severe consequences for the patients. The aim is to re......Background: Nutrition plays an important role to the success of fast track programs, but under nutrition are still reported. Nutritional care seems to be a low priority among nurses even though it is well-known that insufficient nutrition has severe consequences for the patients. The aim...... is to report to what extent a training program has made Nutritional Nurse Practitioners aware of the nutritional care for short-term hospitalized patients, and how they deal with patients’ nutritional needs and ability to provide self-care in the context of a fast track program. Methods: Deductive content...... analysis was used to analyse data from four focus group interviews. Sixteen Nutritional Nurse Practitioners from either medical or surgery wards participated. The Nutritional Nurse Practitioners were interviewed twice. The interviews were recorded and verbally transcribed. Results: In the Nutritional Nurse...

  5. Experience with "Fast track" postoperative care after deep brain stimulation surgery.

    Science.gov (United States)

    Martín, Nuria; Valero, Ricard; Hurtado, Paola; Gracia, Isabel; Fernández, Carla; Rumià, Jordi; Valldeoriola, Francesc; Carrero, Enrique J; Tercero, Francisco Javier; de Riva, Nicolás; Fàbregas, Neus

    A 24-h-stay in the post-anesthesia care unit (PACU) is a common postoperative procedure after deep brain stimulation surgery (DBS). We evaluated the impact of a fast-track (FT) postoperative care protocol. An analysis was performed on all patients who underwent DBS in 2 periods: 2006, overnight monitored care (OMC group), and 2007-2013, FT care (FT group). The study included 19 patients in OMC and 95 patients in FT. Intraoperative complications occurred in 26.3% patients in OMC vs. 35.8% in FT. Post-operatively, one patient in OMC developed hemiparesis, and agitation in 2 patients. In FT, two patients with intraoperative hemiparesis were transferred to the ICU. While on the ward, 3 patients from the FT developed hemiparesis, two of them 48h after the procedure. Thirty eight percent of FT had an MRI scan, while the remaining 62% and all patients of OMC had a CT-scan performed on their transfer to the ward. One patient in OMC had a subthalamic hematoma. Two patients in FT had a pallidal hematoma, and 3 a bleeding along the electrode. A FT discharge protocol is a safe postoperative care after DBS. There are a small percentage of complications after DBS, which mainly occur within the first 6h. Copyright © 2016 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Development of data acquisition system for tracing fast flow using GPIB

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jung, Sung Hee

    2003-12-01

    Radiotracer data acquisition system which was developed by radiotracer group in Korea Atomic Energy Research Institute has been used for field experiment since the late of 1990s. It has RS232C and 24 channel x10 sample. It was useful for radiotracer experiment whose period span from few second to few ten days. But the demand for tracing fast flow has been increasing. For example, to trace a fast gas flow in petro chemical industry or for application like computer aided radioactive particle tracking, high speed data acquisition system is necessary. The current commercial data acquisition systems have limited count channels. To solve above mentioned problem upgraded high speed data acquisition system using GPIB is developed. GPIB system is one method of control and communication. The data transmit speed of GPIB is 200k byte/sec which is faster then 20k bps of RS232C. In addition to that, GPIB has advantage of expanding up to 15 devices. It mean that 24 x15 channel is possible if one device has 24channel. It make possible to trace high fast flow or large number of channel. This technical report include details of the design of high speed multi-channel radiation detecting system which is consist of ratemeter module, display unit, mainboard with GPIB system and 24 channel counter board. The design of GPIB system developed here is also applicable to other measurement system for various applications.

  7. Development of data acquisition system for tracing fast flow using GPIB

    International Nuclear Information System (INIS)

    Kim, Jong Bum; Jung, Sung Hee

    2003-12-01

    Radiotracer data acquisition system which was developed by radiotracer group in Korea Atomic Energy Research Institute has been used for field experiment since the late of 1990s. It has RS232C and 24 channel x10 sample. It was useful for radiotracer experiment whose period span from few second to few ten days. But the demand for tracing fast flow has been increasing. For example, to trace a fast gas flow in petro chemical industry or for application like computer aided radioactive particle tracking, high speed data acquisition system is necessary. The current commercial data acquisition systems have limited count channels. To solve above mentioned problem upgraded high speed data acquisition system using GPIB is developed. GPIB system is one method of control and communication. The data transmit speed of GPIB is 200k byte/sec which is faster then 20k bps of RS232C. In addition to that, GPIB has advantage of expanding up to 15 devices. It mean that 24 x15 channel is possible if one device has 24channel. It make possible to trace high fast flow or large number of channel. This technical report include details of the design of high speed multi-channel radiation detecting system which is consist of ratemeter module, display unit, mainboard with GPIB system and 24 channel counter board. The design of GPIB system developed here is also applicable to other measurement system for various applications

  8. Predictors of length of stay and patient satisfaction after hip and knee replacement surgery: fast-track experience in 712 patients

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte; Jacobsen, Steffen

    2008-01-01

    BACKGROUND AND PURPOSE: Very few studies have focused on patient characteristics that influence length of stay (LOS) in fast-track total hip (THR) and knee arthroplasty (TKR). The aim of this prospective study was to identify patient characteristics associated with LOS and patient satisfaction...... after total hip and knee replacement surgery. PATIENTS AND METHODS: Between September 2003 and December 2005, 712 consecutive, unselected patients (440 women) with a mean age of 69 (31-91) years were admitted for hip and knee replacement surgery at our specialized fast-track joint replacement unit....... Epidemiological, physical, and perioperative parameters were registered and correlated to LOS and patient satisfaction. RESULTS: 92% of the patients were discharged directly to their homes within 5 days, and 41% were discharged within 3 days. Age, sex, marital status, co-morbidity, preoperative use of walking...

  9. Integrated quality status and inventory tracking system for FFTF driver fuel pins

    International Nuclear Information System (INIS)

    Gottschalk, G.P.

    1979-11-01

    An integrated system for quality status and inventory tracking of Fast Flux Test Facility (FFTF) driver fuel pins has been developed. Automated fuel pin identification systems, a distributed computer network, and a data base are used to implement the tracking system

  10. Outcomes in smokers and alcohol users after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, C C; Kehlet, Henrik; Hansen, Torben Bæk

    2013-01-01

    and knee arthroplasty. RESULTS: In 3041 consecutive patients, 458 reported smoking and 216 drinking > 2 drinks a day, of which 66 did both. Smokers/alcohol users were younger than non-users (mean age: 64.3 vs. 68.0 years, P  4 days and smoking (odds ratio [95% confidence interval], P) (1.34 [0.92-1.95], 0......BACKGROUND: Smoking and alcohol use impair post-operative outcomes. However, no studies include fast-track surgery, which is a multimodal-enhanced recovery programme demonstrated to improve outcome. We hypothesised that outcome is similar in smokers and alcohol users as in non-users after fast.......127) or alcohol use (0.59 [0.30-1.16], 0.127). Thirty- and ninety-day readmission rate was 6.6% (n = 201) and 9.4% (n = 285). Multiple logistic regression analysis showed an increased risk of readmissions in smokers at 30 (1.60 [1.05-2.44], 0.028) but not 90-day follow-up (1.17 [0.80-1.73], 0.419). No increased...

  11. A fast and flexible reactor physics model for simulating neutron spectra and depletion in fast reactors - 202

    International Nuclear Information System (INIS)

    Recktenwald, G.D.; Bronk, L.A.; Deinert, M.R.

    2010-01-01

    Determining the time dependent concentration of isotopes within a nuclear reactor core is central to the analysis of nuclear fuel cycles. We present a fast, flexible tool for determining the time dependent neutron spectrum within fast reactors. The code (VBUDS: visualization, burnup, depletion and spectra) uses a two region, multigroup collision probability model to simulate the energy dependent neutron flux and tracks the buildup and burnout of 24 actinides, as well as fission products. While originally developed for LWR simulations, the model is shown to produce fast reactor spectra that show high degree of fidelity to available fast reactor benchmarks. (authors)

  12. Health preemption behind closed doors: trade agreements and fast-track authority.

    Science.gov (United States)

    Crosbie, Eric; Gonzalez, Mariaelena; Glantz, Stanton A

    2014-09-01

    Noncommunicable diseases result from consuming unhealthy products, including tobacco, which are promoted by transnational corporations. The tobacco industry uses preemption to block or reverse tobacco control policies. Preemption removes authority from jurisdictions where tobacco companies' influence is weak and transfers it to jurisdictions where they have an advantage. International trade agreements relocate decisions about tobacco control policy to venues where there is little opportunity for public scrutiny, participation, and debate. Tobacco companies are using these agreements to preempt domestic authority over tobacco policy. Other transnational corporations that profit by promoting unhealthy foods could do the same. "Fast-track authority," in which Congress cedes ongoing oversight authority to the President, further distances the public from the debate. With international agreements binding governments to prioritize trade over health, transparency and public oversight of the trade negotiation process is necessary to safeguard public health interests.

  13. Postoperative anemia and early functional outcomes after fast-track hip arthroplasty

    DEFF Research Database (Denmark)

    Jans, Øivind; Bandholm, Thomas; Kurbegovic, Sorel

    2016-01-01

    BACKGROUND: Postoperative anemia is prevalent in fast-track hip arthroplasty (THA) where patients are mobilized and discharged early, but whether anemia impairs functional recovery after discharge has not been adequately evaluated previously. This study aimed to evaluate whether postoperative...... anemia influenced recovery of mobility and quality of life (Qol) during the first 2 weeks after discharge from THA. STUDY DESIGN AND METHODS: This was a prospective observational study in 122 THA patients more than 65 years of age. Mobility and Qol were assessed pre- and postoperatively by the 6-minute...... walk test (6MWT; primary outcome), the timed up-and-go test, and the FACT-anemia subscale. Twenty-four-hour mobility at home was assessed by activity monitoring on Days 1 to 6 after discharge. Hemoglobin (Hb) at discharge (HbD) and the Hb decrease from preoperatively (ΔHb) were compared to mobility...

  14. 171. Funcionamiento y resultados del programa de fast-track en el tratamiento de la tetralogía de fallot

    Directory of Open Access Journals (Sweden)

    J. Orrit Palacios

    2010-01-01

    Conclusiones: La corrección completa de la tetralogía de Fallot con el programa de fast-track de anestesia disminuye la ventilación mecánica, la estancia en cuidados intensivos y el tiempo de hospitalización. Asimismo se reducen los costes económicos del tratamiento.

  15. Analysis of etchants behavior on the electrochemical etching amplification of fast-neutron-induced recoil particle tracks in polycarbonate

    International Nuclear Information System (INIS)

    Masnadi Shirazi Nezhad, K.

    1979-08-01

    The composition, concentration, and temperature of etchant are important parameters controlling electrochemical etching (ECE) amplification of charged particle tracks in polymers. These parameters were further studied for sohralir polycarbonate neutron dosimeter (Sohrabi 1974), using potassium hydroxide (KOH) and sodium hydroxide (NaOH) solutions, and a mixture of potassium hydroxide, ethanol, and water (PEW solution), at different concentrations applying a field strength of 32KV/cm at 2KHz frequency using 250 μ thick polycarbonate exposed to fast neutrons. The recoal track density per rad of neutrons, in general, was found to increase by increasing the etchant concentration reaching a semi-platean after which it increases again. This increase is up to a concentration at which a track removing process occurs and no tracks have been amplified anymore. This track removing process occurred at about 11 normality in both KOH (50% by weight) and NaOH (30% by weight) solution at 25degC. The mean track diameter, in general, passed through a cyclic variation having a maximun and a minimum. For NaOH solution, the track removing process occurred at the minimum point. In the three regions of the track diameter curve the tracks appear in different shapes especially in KOH solution. The PEW solution at its optimum conditions was more effective in terms of both sensitivity, track diameter and a shorter period of etching. The chemical mechanism of etching process may be explained to be a ''saponification'' process. These studies further support the adequacy of Sohrabi dosimeter for routing health physics and radiation research applications. The above parameters are further discussed and the results as well as the advantages and disadvantages of the above etchants are given. (author)

  16. Some nuclear track technologies developed recently for practical purposes

    International Nuclear Information System (INIS)

    Hao Xiuhong

    2000-01-01

    For practical purposes three kinds of nuclear track technologies developed recently are described. They are coloring of nuclear track, nuclear track sheet replication and molding of micro metallic cones from nuclear tracks

  17. A method for the measurement of fission rates in fast neutron fields using solid state track detectors

    International Nuclear Information System (INIS)

    Hansen, W.; Vogel, W.

    1984-04-01

    Solid state track detectors (SSTDs) are increasingly used for the registration of radiation in different fields of nuclear physics. Because of their small sizes and masses and the absence of any electronics during exposure SSTDs do not cause distortions in the system to be investigated and are useful for measurements at such places being difficult of access. The elaboration of a method is described for fission rate measurements in fast neutron fields applying SSTDs and different fissionable isotopes which were electrodeposited on stainless steel backings. Experiences of the electrodeposition and results of quality checks are presented. The evaluation of the etched tracks is performed with spark counter technique. The dependence of the counting result on essential influence parameters is discussed. (author)

  18. Application of solid state nuclear track detectors in radiation protection

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Subba Ramu, M.C.; Mishra, U.C.

    1989-01-01

    This article reviews the current status of the application of nuclear track detectors with emphasis on recent developments in the field of radiation protection. Track etch detectors have been used for the measurements of low level radiation in the environment, fast neutron and radon daughter inhalation dose. Recent developments in the field of dosimetry seem to be promising. In fast neutron dosimetry, track etch detectors can be used without inclusion of fissile materials by using the electrochemical etching technique. These detectors can provide important information in the energy range upto 250 keV. Survey of this range of energy with TLD is difficult because they are extremely energy dependent and over-respond to low energy neutrons. Measurement of radon using track detectors can help to lower the cost of the radon dosimeters. Certain detectors are sensitive to alpha particles from radon and their progeny. Higher sensitivity permits their use in a passive type of personnel dosimeter, which does not require the troublesome aspects of air sampling for the collection of radon daughter samples. (author), 38 refs., 8 tabs., 12 figs

  19. Development of the ZEUS central tracking detector

    Science.gov (United States)

    Brooks, C. B.; Bullock, F. W.; Cashmore, R. J.; Devenish, R. C.; Foster, B.; Fraser, T. J.; Gibson, M. D.; Gilmore, R. S.; Gingrich, D.; Harnew, N.; Hart, J. C.; Heath, G. P.; Hiddleston, J.; Holmes, A. R.; Jamdagni, A. K.; Jones, T. W.; Llewellyn, T. J.; Long, K. R.; Lush, G. J.; Malos, J.; Martin, N. C.; McArthur, I.; McCubbin, N. A.; McQuillan, D.; Miller, D. B.; Mobayyen, M. M.; Morgado, C.; Nash, J.; Nixon, G.; Parham, A. G.; Payne, B. T.; Roberts, J. H. C.; Salmon, G.; Saxon, D. H.; Sephton, A. J.; Shaw, D.; Shaw, T. B.; Shield, P. D.; Shulman, J.; Silvester, I.; Smith, S.; Strachan, D. E.; Tapper, R. J.; Tkaczyk, S. M.; Toudup, L. W.; Wallis, E. W.; Wastie, R.; Wells, J.; White, D. J.; Wilson, F. F.; Yeo, K. L.; ZEUS-UK Collaboration

    1989-11-01

    The design concept and development of the ZEUS central tracking detector is described. This is a cylindrical drift chamber designed for track reconstruction, electron identification and event triggering in a high-crossing-rate, high-magnetic-field environment.

  20. Inhibiting Interference - a grounded theory of health professionals' pattern of behaviour related to the relatives of older patients in fast-track treatment programmes

    DEFF Research Database (Denmark)

    Berthelsen, Connie Bøttcher; Lindhardt, Tove; Frederiksen, Kirsten

    2014-01-01

    AIM: To generate a grounded theory explaining health professionals' pattern of behaviour and experience related to the relatives of older patients in fast-track treatment programmes during total joint replacement. BACKGROUND: Health professionals uphold standardised care for patients, and effect...... on quality is seen when relatives support patients during total joint replacement. Since health professionals often have problematic relationships with relatives, knowledge is needed of the health professionals' pattern of behaviour in relation to relatives of older patients in fast-track treatment programme....... DESIGN: Grounded theory according to Glaser's methodology was used to generate substantive theory of health professionals' pattern of behaviour. METHODS: Data were collected from 2010 to 2011 by 44 health professionals in orthopaedic wards at two Danish hospitals. Data from nonparticipant observations...

  1. Cyclo-oxygenase 2 inhibitors and the risk of anastomotic leakage after fast-track colonic surgery

    DEFF Research Database (Denmark)

    Holte, K; Andersen, Jens; Jakobsen, D Hjort

    2009-01-01

    -oxygenase inhibitor for postoperative analgesia. METHODS: Patients with anastomotic leakage following a standard fast-track procotol between April 1997 and May 2006 were identified from a prospective, consecutive database. During this period there were two changes in perioperative management: cessation......BACKGROUND: Anastomotic leakage occurs after 3-6 per cent of colonic resections. The influence of analgesic agents is largely unknown. This study determined the rate of anastomotic leakage in a series of patients who had colonic surgery over a 9-year period with or without use of a cyclo...

  2. Development of the ZEUS central tracking detector

    International Nuclear Information System (INIS)

    Brooks, C.B.; Cashmore, R.J.; Gingrich, D.; Harnew, N.; Heath, G.P.; Holmes, A.R.; Martin, N.C.; McArthur, I.; Nash, J.; Salmon, G.; Shield, P.D.; Silvester, I.; Smith, S.; Wastie, R.; Wells, J.; Jamdagni, A.K.; McQuillan, D.; Miller, D.B.; Mobayyen, M.M.; Shulman, J.; Toudup, L.W.

    1989-01-01

    The design concept and development of the ZEUS central tracking detector is described. This is a cylindrical drift chamber designed for track reconstruction, electron identification and event triggering in a high-crossing-rate, high-magnetic-field environment. (orig.)

  3. Health Preemption Behind Closed Doors: Trade Agreements and Fast-Track Authority

    Science.gov (United States)

    Crosbie, Eric; Gonzalez, Mariaelena

    2014-01-01

    Noncommunicable diseases result from consuming unhealthy products, including tobacco, which are promoted by transnational corporations. The tobacco industry uses preemption to block or reverse tobacco control policies. Preemption removes authority from jurisdictions where tobacco companies’ influence is weak and transfers it to jurisdictions where they have an advantage. International trade agreements relocate decisions about tobacco control policy to venues where there is little opportunity for public scrutiny, participation, and debate. Tobacco companies are using these agreements to preempt domestic authority over tobacco policy. Other transnational corporations that profit by promoting unhealthy foods could do the same. “Fast-track authority,” in which Congress cedes ongoing oversight authority to the President, further distances the public from the debate. With international agreements binding governments to prioritize trade over health, transparency and public oversight of the trade negotiation process is necessary to safeguard public health interests. PMID:25033124

  4. Prototypdetektoren für das geplante Upgradeprojekt 'Muon Track Fast Tag' am CMS-Experiment

    CERN Document Server

    Weingarten, Simon; Stahl, Achim

    Upgrading the muon system will be one of the major challenges for the CMS experiment atthe projected high luminosity LHC (HL-LHC) with an expected instantaneous luminosityof L = 1035 /(cm2 · s). Most importantly, the muon trigger rate has to be reduced inorder to keep the level 1 trigger rate inside the reserved bandwidth. Another concernthat has to be dealt with is the rising number of ambiguities in the muon chambers dueto simultaneously traversing muons, so-called ghost hits. With the Muon Track fast Tag(MTT), a new detector subsystem between the CMS solenoid and the first muon stationis proposed to solve these problems. An implementation of the MTT system based on fastplastic scintillators read out by silicon photomultipliers (SiPM) is under development atthe Physics Institute III of RWTH Aachen University.In this thesis, results of prototype detectors with 100 × 100 × 5 mm3 scintillator-tilesand dual SiPM-readout are presented. All studies have been done with cosmic muons andfocus on parameter optimi...

  5. Measurements of fast deuterons from plasma accelerator by means of PM-355 track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Skladnik-Sadowska, E. [Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Otwock-Swierk (Poland); Malinowski, K., E-mail: k.malinowski@ipj.gov.p [Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Otwock-Swierk (Poland); Sadowski, M.J.; Czaus, K. [Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Otwock-Swierk (Poland)

    2009-10-15

    This paper reports on studies of fast ions (mostly deuterons) emitted from an RPI (Rod-Plasma-Injector) plasma accelerator. The first aim was the verification of applicability of PM-355 track detectors for dosimetry of lower-energy (<200 KeV) deuterons. The second aim was information about energy spectra of deuterons from RPI-IBIS device in different operational modes. Mass- and energy spectra of ions were investigated with a Thomson-analyzer and PM-355 detectors. On the recorded deuteron-parabolas we chose points, and from numbers of tracks we determined the deuteron energy distribution. In the slow-mode the energy distribution peak was observed at about 40 keV, while the maximum energy amounted to about 150 keV. Those measurements confirmed an influence of the initial gas-conditions on energy distributions of the deuteron streams. The results are of importance for plasma-physics and applications. Another result was the confirmation that PM-355 detectors might be used for accurate measurements of low-energy (<200 keV) deuterons.

  6. 'Fast-track' colonic surgery in Austria and Germany--results from the survey on patterns in current perioperative practice.

    Science.gov (United States)

    Hasenberg, T; Keese, M; Längle, F; Reibenwein, B; Schindler, K; Herold, A; Beck, G; Post, S; Jauch, K W; Spies, C; Schwenk, W; Shang, E

    2009-02-01

    'Fast-track' rehabilitation has been shown to accelerate recovery, reduce general morbidity and decrease hospital stay after elective colonic surgery. Despite this evidence, there is no information on the acceptance and utilization of these concepts among the entirety of Austrian and German surgeons. In 2006, a questionnaire concerning perioperative routines in elective, open colonic resection was sent to the chief surgeons of 1270 German and 120 Austrian surgical centres. The response rate was 63% in Austria (76 centres) and 30% in Germany (385 centres). Mechanical bowel preparation is used by the majority (Austria, 91%; Germany, 94%); the vertical incision is the standard method of approach to the abdomen in Austria (79%) and Germany (83%), nasogastric decompression tubes are rarely used, one-third of the questioned surgeons in both countries use intra-abdominal drains. Half of the surgical centres allow the intake of clear fluids on the day of surgery and one-fifth offer solid food on that day. Epidural analgesia is used in three-fourths of the institutions. Although there is an evident benefit of fast-track management, the survey shows that they are not yet widely used as a routine in Austria and Germany.

  7. A C++ object-oriented toolkit for track finding with k-dimensional hits

    International Nuclear Information System (INIS)

    Uiterwijk, J.W.E.; Panman, J.; Vyver, B. van de

    2006-01-01

    A library is described for the recognition of tracks in a set of hits. The hits are assumed to be k-dimensional points (k-d), with k>=1, of which a subset can be grouped into tracks by using short-range correlations. A connection graph between the hits is created by sorting the hits first in k-d space using one of the developed, fast, k-space containers. The track-finding algorithm considers any connection between two hits as a possible track seed and grows these seeds into longer track segments using a modified depth-first search of the connection graph. All hit-acceptance decisions are called via abstract methods of an acceptance criterion class which isolates the library from the application's hit and track model. An application is tuned for a particular tracking environment by creating a concrete implementation for the hit and track acceptance calculations. The implementer is free to trade tracking time for acceptance complexity (influencing efficiency) depending on the requirements of the particular application. Results for simulated data show that the track finding is both efficient and fast even for high noise environments

  8. Development of a railway wagon-track interaction model: Case studies on excited tracks

    Science.gov (United States)

    Xu, Lei; Chen, Xianmai; Li, Xuwei; He, Xianglin

    2018-02-01

    In this paper, a theoretical framework for modeling the railway wagon-ballast track interactions is presented, in which the dynamic equations of motion of wagon-track systems are constructed by effectively coupling the linear and nonlinear dynamic characteristics of system components. For the linear components, the energy-variational principle is directly used to derive their dynamic matrices, while for the nonlinear components, the dynamic equilibrium method is implemented to deduce the load vectors, based on which a novel railway wagon-ballast track interaction model is developed, and being validated by comparing with the experimental data measured from a heavy haul railway and another advanced model. With this study, extensive contributions in figuring out the critical speed of instability, limits and localizations of track irregularities over derailment accidents are presented by effectively integrating the dynamic simulation model, the track irregularity probabilistic model and time-frequency analysis method. The proposed approaches can provide crucial information to guarantee the running safety and stability of the wagon-track system when considering track geometries and various running speeds.

  9. Fast processor for dilepton triggers

    International Nuclear Information System (INIS)

    Katsanevas, S.; Kostarakis, P.; Baltrusaitis, R.

    1983-01-01

    We describe a fast trigger processor, developed for and used in Fermilab experiment E-537, for selecting high-mass dimuon events produced by negative pions and anti-protons. The processor finds candidate tracks by matching hit information received from drift chambers and scintillation counters, and determines their momenta. Invariant masses are calculated for all possible pairs of tracks and an event is accepted if any invariant mass is greater than some preselectable minimum mass. The whole process, accomplished within 5 to 10 microseconds, achieves up to a ten-fold reduction in trigger rate

  10. An algorithm for symplectic implicit Taylor-map tracking

    International Nuclear Information System (INIS)

    Yan, Y.; Channell, P.; Syphers, M.

    1992-10-01

    An algorithm has been developed for converting an ''order-by-order symplectic'' Taylor map that is truncated to an arbitrary order (thus not exactly symplectic) into a Courant-Snyder matrix and a symplectic implicit Taylor map for symplectic tracking. This algorithm is implemented using differential algebras, and it is numerically stable and fast. Thus, lifetime charged-particle tracking for large hadron colliders, such as the Superconducting Super Collider, is now made possible

  11. Electrochemical development of particle tracks in CR-39 polymer dosimeter

    International Nuclear Information System (INIS)

    Hadlock, D.E.; Parkhurst, M.A.; Yang, C.S.; Groeger, J.; Johnson, J.R.; Huang, S.J.

    1985-09-01

    Electrochemical etching of CR-39 polymeric track etch neutron detectors results in proton-recoil tracks can be distinguished from background tracks much better than tracks developed solely by chemical etching. A newly designed and constructed electrochemical etching apparatus allows large numbers of dosimeters to be processed simultaneously with consistent results. Many processing systems have been developed for chemical and electrochemical etching of the track etch dosimeters. Three systems specifically show great promise and are being studied extensively

  12. Fast algorithm of track detection

    International Nuclear Information System (INIS)

    Nehrguj, B.

    1980-01-01

    A fast algorithm of variable-slope histograms is proposed, which allows a considerable reduction of computer memory size and is quite simple to carry out. Corresponding FORTRAN subprograms given a triple speed gain have been included in spiral reader data handling software

  13. Post-discharge symptoms following fast-track colonic cancer surgery: a phenomenological hermeneutic study

    DEFF Research Database (Denmark)

    Krogsgaard, Marianne; Dreyer, Pia; Egerod, Ingrid

    2014-01-01

    OBJECTIVE: To obtain knowledge of patients' experiences of postoperative symptoms during the initial two weeks following fast-track colonic cancer surgery. METHOD: Semi-structured in-depth interviews with seven colonic cancer patients two weeks post hospital discharge. Analysis was performed using...... a phenomenological hermeneutical approach. RESULTS: During the first two weeks after discharge the patients experienced unfamiliar symptoms that affected their everyday lives. Despite distressing symptoms, they applied a "wait-and-see" strategy, and only reacted when symptoms became intolerable. The patients failed...... to shorter hospitalisation and improved physical performance, post-colonic surgery patients experience various symptoms after discharge. Healthcare professionals need to address symptoms that might have immediate and long-term consequences on patients' everyday life. Follow-up studies are encouraged...

  14. Mass tracking and material accounting in the Integral Fast Reactor (IFR)

    International Nuclear Information System (INIS)

    Orechwa, Y.; Adams, C.H.; White, A.M.

    1991-01-01

    The Integral Fast Reactor (IFR) is a generic advanced liquid metal cooled reactor concept being developed at Argonne National Laboratory (ANL). There are a number of technical features of the IFR which contribute to its potential as a next-generation reactor. These are associated with large safety margins with regard to off-normal events involving the heat transport system, and the use of metallic fuel which makes possible the utilization of innovative fuel cycle processes. The latter feature permits fuel cycle closure the compact, low-cost reprocessing facilities, collocated with the reactor plant. These primary features are being demonstrated in the facilities at ANL-West, utilizing Experimental Breeder Reactor 2 and the associated Fuel Cycle Facility (FCF) as an IFR prototype. The demonstration of this IFR prototype includes the design and implementation of the Mass-Tracking System (MTG). In this system, data from the operations of the FCF, including weights and batch-process parameters, are collected and maintained by the MTG running on distributed workstations. The components of the MTG System include: (1) an Oracle database manager with a Fortran interface, (2) a set of MTG ''Tasks'' which collect, manipulate and report data, (3) a set of MTG ''Terminal Sessions'' which provide some interactive control of the Tasks, and (4) a set of servers which manage the Tasks and which provide the communications link between the MTG System and Operator Control Stations, which control process equipment and monitoring devices within the FCF

  15. The fast tracker processor for hadron collider triggers

    CERN Document Server

    Annovi, A; Bardi, A; Carosi, R; Dell'Orso, Mauro; D'Onofrio, M; Giannetti, P; Iannaccone, G; Morsani, E; Pietri, M; Varotto, G

    2001-01-01

    Perspectives for precise and fast track reconstruction in future hadron collider experiments are addressed. We discuss the feasibility of a pipelined highly parallel processor dedicated to the implementation of a very fast tracking algorithm. The algorithm is based on the use of a large bank of pre-stored combinations of trajectory points, called patterns, for extremely complex tracking systems. The CMS experiment at LHC is used as a benchmark. Tracking data from the events selected by the level-1 trigger are sorted and filtered by the Fast Tracker processor at an input rate of 100 kHz. This data organization allows the level-2 trigger logic to reconstruct full resolution tracks with transverse momentum above a few GeV and search for secondary vertices within typical level-2 times. (15 refs).

  16. Tracking adaptation and measuring development

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, Nick; Anderson, Simon; Ayers, Jessica; Burton, Ian; Tellam, Ian

    2011-11-15

    This is the first paper in the new IIED Climate Change Working Paper series. As adaptation to climate change becomes the focus of increasing attention and the target of significant spending, there is a growing need for frameworks and tools that enable organisations to track and assess the outcomes of adaptation interventions. This paper presents a coherent framework for climate change adaptation programming, including potential indicators, or indicator categories/types, for tracking and evaluating the success of adaptation support and adaptation interventions. The paper begins with a discussion of some of the key issues related to the evaluation of adaptation, and outlines some of the main difficulties and constraints with respect to the development of adaptation indicators. Next, an evaluation framework is proposed and indicator categories or 'domains' are identified. Lastly, key conclusions are provided and a theory of change is outlined that shows how development and use of the framework could lead to more effective adaptation investments for climate resilient development.

  17. Direct hospital costs of total laparoscopic hysterectomy compared with fast-track open hysterectomy at a tertiary hospital: a retrospective case-controlled study.

    Science.gov (United States)

    Rhou, Yoon J J; Pather, Selvan; Loadsman, John A; Campbell, Neil; Philp, Shannon; Carter, Jonathan

    2015-12-01

    To assess the direct intraoperative and postoperative costs in women undergoing total laparoscopic hysterectomy and fast-track open hysterectomy. A retrospective review of the direct hospital-related costs in a matched cohort of women undergoing total laparoscopic hysterectomy (TLH) and fast-track open hysterectomy (FTOH) at a tertiary hospital. All costs were calculated, including the cost of advanced high-energy laparoscopic devices. The effect of the learning curve on cost in laparoscopic hysterectomy was also assessed, as was the hospital case-weighted cost, which was compared with the actual cost. Fifty women were included in each arm of the study. TLH had a higher intraoperative cost, but a lower postoperative cost than FTOH (AUD$3877 vs AUD$2776 P funding model in our hospital is inaccurate when compared to directly calculated hospital costs. © 2013 The Authors ANZJOG © 2013 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  18. Global track finder for Belle II experiment

    Energy Technology Data Exchange (ETDEWEB)

    Trusov, Viktor; Feindt, Michael; Heck, Martin; Kuhr, Thomas; Goldenzweig, Pablo [Karlsruhe Institute of Technology, IEKP (Germany); Collaboration: Belle II-Collaboration

    2015-07-01

    We present an implementation of a method based on the Legendre transformation for reconstruction charged particle tracks in the central drift chamber of the Belle II experiment. The method is designed for fast track finding and restoring circular patterns of track hits in transverse plane. It is done by searching for common tangents to drift circles of hits in the conformal space. With known transverse trajectories longitudinal momentum estimation performed by assigning stereo hits followed by determination of the track parameters. The method includes algorithms responsible for track quality estimation and reduction of rate of fakes. The work is targeting at increasing the efficiency and reducing the execution time because the computing power available to the experiment is limited. The algorithm is developed within the Belle II software environment with using Monte-Carlo simulation for probing its efficiency.

  19. Development of etched nuclear tracks

    International Nuclear Information System (INIS)

    Somogyi, G.

    1980-01-01

    The theoretical description of the evolution of etched tracks in solid state nuclear track detectors is considered for different initial conditions, for the cases of constant and varying track etch rates, isotropic and anisotropic bulk etching as well as for thick and thin detectors. It is summarized how one can calculate the main parameters of etch-pit geometry, the track length, the axes of a surface track opening, track profile and track contour. The application of the theory of etch-track evolution is demonstrated with selected practical problems. Attention is paid to certain questions related to the determination of unknown track parameters and calculation of surface track sizes. Finally, the theory is extended to the description of the perforation and etch-hole evolution process in thin detectors, which is of particular interest for track radiography and nuclear filter production. (orig.)

  20. Development of etched nuclear tracks

    International Nuclear Information System (INIS)

    Somogyi, G.

    1979-01-01

    The theoretical description of the evolution of etched tracks in solid state nuclear track detectors is considered for different initial conditions, for the cases of constant and varying track etch rates, isotopic and unisotropic bulk etching as well as for thick and thin detectors. It is summarized how the main parameters of etch-pit geometry, the track length, the axes of a surface track opening, the track profile and the track contour can be calculated. The application of the theory of etch-track evolution is demonstrated with selected practical problems. Attention is paid to certain questions related to the determination of unknown track parameters and calculation of surface track sizes. Finally, the theory is extended to the description of the perforation and etch-hole evolution process in thin detectors, which is of particular interest for track radiography and nuclear filter production. (author)

  1. A fast track approach to commercializing the sodium cooled fast reactor

    International Nuclear Information System (INIS)

    Boardman, C.E.; Hui, Marvin; Carroll, Douglas

    1999-01-01

    As a result of more than 50 years of Liquid Metal Reactor design and development work the basic technology is well understood. However, commercialization of the Fast Breeder Reactor (FBR) has been delayed while various approaches to achieving competitive plant and fuel cycle costs are explored, developed, and demonstrated in prototype systems. Most designers have elected to take advantage of the economy of scale but are burdened by the cost and risk associated with the need for incremental scale up through the design, construction, and operation of multiple demonstration plants. An alternative commercialization path developed by GE would utilize a modular plant design to reduce the plant construction, R and D, and economic risk associated with the need to build multiple demonstration plants to reach a competitive size'. The key question is can a modular FBR compete with alternative electrical generation systems? Recently completed studies indicate that the answer to this question is yes if the modular plant designers keep the design simple by incorporating passive safety features and optimizing the manner in which supporting service systems are shared. (author)

  2. The Fast TracKer

    CERN Document Server

    Potamianos, Karolos Jozef; The ATLAS collaboration

    2018-01-01

    The Fast Tracker (FTK) is a hardware upgrade to the ATLAS trigger and data acquisition system providing global track reconstruction to the High-Level Trigger (HLT) with the goal to improve pile-up rejection. The FTK processes incoming data from the Pixel and SCT detectors (part of the Inner Detector, ID) at up to 100 kHz using custom electronic boards. ID hits are matched to pre-defined track patterns stored in associative memory (AM) on custom ASICs and data routing, reduction and parameter extraction is achieved with processing on FPGAs. With 8000 AM chips and 2000 FPGAs, the FTK provides enough resources to reconstruct tracks with transverse momentum greater than 1 GeV/c in the whole tracking volume with an average latency below 100 microseconds at collisions intensities expected in Runs II and III of the LHC. The tracks will be available at the beginning of the trigger selection process, which allows development of pile-up resilient triggering strategies to identify b-quarks and tau-leptons, as well as pr...

  3. The Fast Simulation Chain for ATLAS

    CERN Document Server

    Basalaev, Artem; The ATLAS collaboration

    2016-01-01

    In order to generate the huge number of Monte Carlo events that will be required by the ATLAS experiment over the next several runs, a very fast simulation is critical. Fast detector simulation alone, however, is insufficient: with very high numbers of simultaneous proton-proton collisions expected in Run 3 and beyond, the digitization (detector response emulation) and event reconstruction time quickly become comparable to the time required for detector simulation. The ATLAS Fast Chain simulation has been developed to solve this problem. Modules are implemented for fast simulation, fast digitization, and fast track reconstruction. The application is sufficiently fast -- several orders of magnitude faster than the standard simulation -- that the simultaneous proton-proton collisions can be generated during the simulation job, so Pythia8 also runs concurrently with the rest of the algorithms. The Fast Chain has been built to be extremely modular and flexible, so that each sample can be custom-tailored to match ...

  4. Future developments in etched track detectors for neutron dosimetry

    International Nuclear Information System (INIS)

    Tommasino, L.

    1987-01-01

    Many laboratories engaged in the field of personal neutron dosimetry are interested in developing better etching processes and improving the CR-39 detecting materials. To know how much effort must still be devoted to the development of etch track dosimetry, it is necessary to understand the advantages. limitations and degree of exploitation of the currently available techniques. So much has been learned about the chemical and electrochemical etching processes that an optimised combination of etching processes could make possible the elimination of many of the existing shortcomings. Limitations of etched track detectors for neutron dosimetry arise mainly because the registration occurs only on the detector surface. These damage type detectors are based on radiation induced chain scission processes in polymers, which result in hole-type tracks in solids. The converse approach, yet to be discovered, would be the development of cure-track detectors, where radiation induced cross linking between organic polymer chains could result in solid tracks in liquids. (author)

  5. Overview of PADC nuclear track readers. Recent trends and solutions

    International Nuclear Information System (INIS)

    Hulber, E.

    2009-01-01

    The development of automated track readers dates back to the first routine dosimetry applications of solid state nuclear track detectors. Many research-laboratory track readers and a few commercial systems were introduced in the past 25 years. The traditional application area for high-throughput track readers is radon testing in buildings and fast neutron dosimetry. The latter application, in particular, has considerably increased the need for efficient polyallyldiglycol carbonate (PADC) track reader systems with high throughput. The paper provides an overview of recent trends in the development of high-throughput PADC track readers and it gives a glimpse into the practice of designing this category of devices. A general overview is provided of the technical aspects relating to the optics, the hardware and the track recognition approaches. Ultimate theoretical limits in the performance as well as promising new approaches are addressed. Requirements and practical solutions are illustrated with reference to a commercially available system.

  6. Transmission electron microscopy porometry of track membranes

    International Nuclear Information System (INIS)

    Reutov, V.F.; Dmitriev, S.N.; Sokhatskij, A.S.; Akap'ev, G.N.

    1998-01-01

    A fast method has been developed for the preparation of a sample appropriate for both SEM and TEM porometry of track membranes with pore channels of various geometric profiles and of size 10 nm and above. The method leads to the electrochemical deposition in the pore channels of a precipitate of monocrystalline copper directly on the surface of a copper foil disk bent into a spherical shape. The tight clamping of the track membrane on the disk surface is carried out by the creation of a vacuum in the space between them

  7. The Fast Simulation Chain for ATLAS

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00399337; The ATLAS collaboration; Marshall, Zach

    2017-01-01

    In order to generate the huge number of Monte Carlo events that will be required by the ATLAS experiment over the next several runs, a very fast simulation is critical. Fast detector simulation alone, however, is insufficient: with very high numbers of simultaneous proton-proton collisions expected in Run 3 and beyond, the digitization (detector response emulation) and event reconstruction time quickly become comparable to the time required for detector simulation. The ATLAS Fast Chain simulation has been developed to solve this problem. Modules are implemented for fast simulation, fast digitization, and fast track reconstruction. The application is sufficiently fast—several orders of magnitude faster than the standard simulation—that the simultaneous proton-proton collisions can be generated during the simulation job, so Pythia8 also runs concurrently with the rest of the algorithms. The Fast Chain has been built to be extremely modular and flexible, so that each sample can be custom-tailored to match th...

  8. A self seeded first level track trigger for ATLAS

    International Nuclear Information System (INIS)

    Schöning, A

    2012-01-01

    For the planned high luminosity upgrade of the Large Hadron Collider, aiming to increase the instantaneous luminosity to 5 × 10 34 cm −2 s −1 , the implementation of a first level track trigger has been proposed. This trigger could be installed in the year ∼ 2021 along with the complete renewal of the ATLAS inner detector. The fast readout of the hit information from the Inner Detector is considered as the main challenge of such a track trigger. Different concepts for the implementation of a first level trigger are currently studied within the ATLAS collaboration. The so called 'Self Seeded' track trigger concept exploits fast frontend filtering algorithms based on cluster size reconstruction and fast vector tracking to select hits associated to high momentum tracks. Simulation studies have been performed and results on efficiencies, purities and trigger rates are presented for different layouts.

  9. Toward the development of intrafraction tumor deformation tracking using a dynamic multi-leaf collimator

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Yuanyuan; O’Brien, Ricky T.; Shieh, Chun-Chien; Keall, Paul J., E-mail: paul.keall@sydney.edu.au [Radiation Physics Laboratory, University of Sydney, NSW 2006 (Australia); Booth, Jeremy T. [Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, NSW 2065 (Australia)

    2014-06-15

    Purpose: Intrafraction deformation limits targeting accuracy in radiotherapy. Studies show tumor deformation of over 10 mm for both single tumor deformation and system deformation (due to differential motion between primary tumors and involved lymph nodes). Such deformation cannot be adapted to with current radiotherapy methods. The objective of this study was to develop and experimentally investigate the ability of a dynamic multi-leaf collimator (DMLC) tracking system to account for tumor deformation. Methods: To compensate for tumor deformation, the DMLC tracking strategy is to warp the planned beam aperture directly to conform to the new tumor shape based on real time tumor deformation input. Two deformable phantoms that correspond to a single tumor and a tumor system were developed. The planar deformations derived from the phantom images in beam's eye view were used to guide the aperture warping. An in-house deformable image registration software was developed to automatically trigger the registration once new target image was acquired and send the computed deformation to the DMLC tracking software. Because the registration speed is not fast enough to implement the experiment in real-time manner, the phantom deformation only proceeded to the next position until registration of the current deformation position was completed. The deformation tracking accuracy was evaluated by a geometric target coverage metric defined as the sum of the area incorrectly outside and inside the ideal aperture. The individual contributions from the deformable registration algorithm and the finite leaf width to the tracking uncertainty were analyzed. Clinical proof-of-principle experiment of deformation tracking using previously acquired MR images of a lung cancer patient was implemented to represent the MRI-Linac environment. Intensity-modulated radiation therapy (IMRT) treatment delivered with enabled deformation tracking was simulated and demonstrated. Results: The first

  10. Development of physical conceptions of fast reactors

    International Nuclear Information System (INIS)

    Khomyakov, Yu.S.; Matveev, V.I.; Moiseev, A.V.

    2013-01-01

    • Russian experience in developing fast reactors has proved clearly scientific justification of conceptual physical principles and their technical feasibility. • However, the potential of fast reactors caused by their physical features has not been fully realized. • In order to assure the real possibility of transition to the nuclear power with fast reactors by about 2030 it is necessary to consistently update fast reactor designs for solving the following key problems: - increasing of self-protection level of reactor core; - improvement of technical and economical characteristics; - solution of the problems related to the fuel supply of nuclear power and assimilation of closed nuclear fuel cycle; - disposal of long lived radioactive waste and transmutation of minor actinides. • Russian program (2010-2020) on the development of basic concepts of the new generation reactors implies successive solution of the above problems. • New technical decisions will be demonstrated by development and assimilation of the new reactors: - BN-800 – development of the fuel cycle infrastructure and mastering of the new types of fuel; - BN-1200 reactor – demonstration economical efficiency of fast reactor and new level of safety; - BREST development and demonstration new heavy liquid metal coolant technology and alternative design concept

  11. The Siegen automatic measuring system for nuclear track detectors: new developments

    International Nuclear Information System (INIS)

    Noll, A.; Rusch, G.; Roecher, H.; Dreute, J.; Heinrich, W.

    1988-01-01

    Starting ten years ago we developed completely automatic scanning and measuring systems for nuclear track detectors. In this paper we describe some new developments. Our autofocus systems based on the contrast of the video picture and on a laser autofocus have been improved in speed and in reliability. Based on new algorithms, faster programs have been developed to scan for nuclear tracks in plastic detectors. Methods for separation of overlapping tracks have been improved. Interactive programs for track measurements have been developed which are very helpful for space bio-physics experiments. Finally new methods for track measurements in nuclear emulsions irradiated with a beam perpendicular to the detector surface are described in this paper. (author)

  12. Status of Fast Reactor Research and Technology Development

    International Nuclear Information System (INIS)

    2012-01-01

    In 1985, the International Atomic Energy Agency (IAEA) published a report titled 'Status of Liquid Metal Cooled Fast Breeder Reactors' (Technical Reports Series No. 246). The report was a general review of the status of fast reactor development at that time, covering some aspects of design and operation and reviewing experience from the earliest days. It summarized the programmes and plans in all countries which were pursuing the development of fast reactors. In 1999, the IAEA published a follow-up report titled 'Status of Liquid Metal Cooled Fast Reactor Technology' (IAEA-TECDOC-1083), necessitated by the substantial advances in fast reactor technology development and changes in the economic and regulatory environment which took place during the period of 1985-1998. Chief among these were the demonstration of reliable operation by several prototypes and experimental reactors, the reliable operation of fuel at a high burnup and the launch of new fast reactor programmes by some additional Member States. In 2006, the Technical Working Group on Fast Reactors (TWG-FR) identified the need to update its past publications and recommended the preparation of a new status report on fast reactor technology. The present status report intends to provide comprehensive and detailed information on the technology of fast neutron reactors. The focus is on practical issues that are useful to engineers, scientists, managers, university students and professors, on the following topics: experience in construction, operation and decommissioning; various areas of research and development; engineering; safety; and national strategies and public acceptance of fast reactors.

  13. Status of Fast Reactor Research and Technology Development

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-04-01

    In 1985, the International Atomic Energy Agency (IAEA) published a report titled 'Status of Liquid Metal Cooled Fast Breeder Reactors' (Technical Reports Series No. 246). The report was a general review of the status of fast reactor development at that time, covering some aspects of design and operation and reviewing experience from the earliest days. It summarized the programmes and plans in all countries which were pursuing the development of fast reactors. In 1999, the IAEA published a follow-up report titled 'Status of Liquid Metal Cooled Fast Reactor Technology' (IAEA-TECDOC-1083), necessitated by the substantial advances in fast reactor technology development and changes in the economic and regulatory environment which took place during the period of 1985-1998. Chief among these were the demonstration of reliable operation by several prototypes and experimental reactors, the reliable operation of fuel at a high burnup and the launch of new fast reactor programmes by some additional Member States. In 2006, the Technical Working Group on Fast Reactors (TWG-FR) identified the need to update its past publications and recommended the preparation of a new status report on fast reactor technology. The present status report intends to provide comprehensive and detailed information on the technology of fast neutron reactors. The focus is on practical issues that are useful to engineers, scientists, managers, university students and professors, on the following topics: experience in construction, operation and decommissioning; various areas of research and development; engineering; safety; and national strategies and public acceptance of fast reactors.

  14. Status of Fast Reactor Research and Technology Development

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    In 1985, the International Atomic Energy Agency (IAEA) published a report titled 'Status of Liquid Metal Cooled Fast Breeder Reactors' (Technical Reports Series No. 246). The report was a general review of the status of fast reactor development at that time, covering some aspects of design and operation and reviewing experience from the earliest days. It summarized the programmes and plans in all countries which were pursuing the development of fast reactors. In 1999, the IAEA published a follow-up report titled 'Status of Liquid Metal Cooled Fast Reactor Technology' (IAEA-TECDOC-1083), necessitated by the substantial advances in fast reactor technology development and changes in the economic and regulatory environment which took place during the period of 1985-1998. Chief among these were the demonstration of reliable operation by several prototypes and experimental reactors, the reliable operation of fuel at a high burnup and the launch of new fast reactor programmes by some additional Member States. In 2006, the Technical Working Group on Fast Reactors (TWG-FR) identified the need to update its past publications and recommended the preparation of a new status report on fast reactor technology. The present status report intends to provide comprehensive and detailed information on the technology of fast neutron reactors. The focus is on practical issues that are useful to engineers, scientists, managers, university students and professors, on the following topics: experience in construction, operation and decommissioning; various areas of research and development; engineering; safety; and national strategies and public acceptance of fast reactors.

  15. Status of Fast Reactor Research and Technology Development

    International Nuclear Information System (INIS)

    2013-01-01

    In 1985, the International Atomic Energy Agency (IAEA) published a report titled 'Status of Liquid Metal Cooled Fast Breeder Reactors' (Technical Reports Series No. 246). The report was a general review of the status of fast reactor development at that time, covering some aspects of design and operation and reviewing experience from the earliest days. It summarized the programmes and plans in all countries which were pursuing the development of fast reactors. In 1999, the IAEA published a follow-up report titled 'Status of Liquid Metal Cooled Fast Reactor Technology' (IAEA-TECDOC-1083), necessitated by the substantial advances in fast reactor technology development and changes in the economic and regulatory environment which took place during the period of 1985-1998. Chief among these were the demonstration of reliable operation by several prototypes and experimental reactors, the reliable operation of fuel at a high burnup and the launch of new fast reactor programmes by some additional Member States. In 2006, the Technical Working Group on Fast Reactors (TWG-FR) identified the need to update its past publications and recommended the preparation of a new status report on fast reactor technology. The present status report intends to provide comprehensive and detailed information on the technology of fast neutron reactors. The focus is on practical issues that are useful to engineers, scientists, managers, university students and professors, on the following topics: experience in construction, operation and decommissioning; various areas of research and development; engineering; safety; and national strategies and public acceptance of fast reactors.

  16. Development of target-tracking algorithms using neural network

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dong Sun; Lee, Joon Whaoan; Yoon, Sook; Baek, Seong Hyun; Lee, Myung Jae [Chonbuk National University, Chonjoo (Korea)

    1998-04-01

    The utilization of remote-control robot system in atomic power plants or nuclear-related facilities grows rapidly, to protect workers form high radiation environments. Such applications require complete stability of the robot system, so that precisely tracking the robot is essential for the whole system. This research is to accomplish the goal by developing appropriate algorithms for remote-control robot systems. A neural network tracking system is designed and experimented to trace a robot Endpoint. This model is aimed to utilized the excellent capabilities of neural networks; nonlinear mapping between inputs and outputs, learning capability, and generalization capability. The neural tracker consists of two networks for position detection and prediction. Tracking algorithms are developed and experimented for the two models. Results of the experiments show that both models are promising as real-time target-tracking systems for remote-control robot systems. (author). 10 refs., 47 figs.

  17. FastSim: A Fast Simulation for the SuperB Detector

    International Nuclear Information System (INIS)

    Andreassen, R; Sokoloff, M; Arnaud, N; Burmistrov, L; Brown, D N; Carlson, J; Gaponenko, I; Suzuki, A; Cheng, C-h; Simone, A Di; Manoni, E; Perez, A; Walsh, J; Rama, M; Roberts, D; Rotondo, M; Simi, G

    2011-01-01

    We have developed a parameterized (fast) simulation for detector optimization and physics reach studies of the proposed SuperB Flavor Factory in Italy. Detector components are modeled as thin sections of planes, cylinders, disks or cones. Particle-material interactions are modeled using simplified cross-sections and formulas. Active detectors are modeled using parameterized response functions. Geometry and response parameters are configured using xml files with a custom-designed schema. Reconstruction algorithms adapted from BaBar are used to build tracks and clusters. Multiple sources of background signals can be merged with primary signals. Pattern recognition errors are modeled statistically by randomly misassigning nearby tracking hits. Standard BaBar analysis tuples are used as an event output. Hadronic B meson pair events can be simulated at roughly 10Hz.

  18. FastSim: A Fast Simulation for the SuperB Detector

    Science.gov (United States)

    Andreassen, R.; Arnaud, N.; Brown, D. N.; Burmistrov, L.; Carlson, J.; Cheng, C.-h.; Di Simone, A.; Gaponenko, I.; Manoni, E.; Perez, A.; Rama, M.; Roberts, D.; Rotondo, M.; Simi, G.; Sokoloff, M.; Suzuki, A.; Walsh, J.

    2011-12-01

    We have developed a parameterized (fast) simulation for detector optimization and physics reach studies of the proposed SuperB Flavor Factory in Italy. Detector components are modeled as thin sections of planes, cylinders, disks or cones. Particle-material interactions are modeled using simplified cross-sections and formulas. Active detectors are modeled using parameterized response functions. Geometry and response parameters are configured using xml files with a custom-designed schema. Reconstruction algorithms adapted from BaBar are used to build tracks and clusters. Multiple sources of background signals can be merged with primary signals. Pattern recognition errors are modeled statistically by randomly misassigning nearby tracking hits. Standard BaBar analysis tuples are used as an event output. Hadronic B meson pair events can be simulated at roughly 10Hz.

  19. On-demand calibration and evaluation for electromagnetically tracked laparoscope in augmented reality visualization.

    Science.gov (United States)

    Liu, Xinyang; Plishker, William; Zaki, George; Kang, Sukryool; Kane, Timothy D; Shekhar, Raj

    2016-06-01

    Common camera calibration methods employed in current laparoscopic augmented reality systems require the acquisition of multiple images of an entire checkerboard pattern from various poses. This lengthy procedure prevents performing laparoscope calibration in the operating room (OR). The purpose of this work was to develop a fast calibration method for electromagnetically (EM) tracked laparoscopes, such that the calibration can be performed in the OR on demand. We designed a mechanical tracking mount to uniquely and snugly position an EM sensor to an appropriate location on a conventional laparoscope. A tool named fCalib was developed to calibrate intrinsic camera parameters, distortion coefficients, and extrinsic parameters (transformation between the scope lens coordinate system and the EM sensor coordinate system) using a single image that shows an arbitrary portion of a special target pattern. For quick evaluation of calibration results in the OR, we integrated a tube phantom with fCalib prototype and overlaid a virtual representation of the tube on the live video scene. We compared spatial target registration error between the common OpenCV method and the fCalib method in a laboratory setting. In addition, we compared the calibration re-projection error between the EM tracking-based fCalib and the optical tracking-based fCalib in a clinical setting. Our results suggest that the proposed method is comparable to the OpenCV method. However, changing the environment, e.g., inserting or removing surgical tools, might affect re-projection accuracy for the EM tracking-based approach. Computational time of the fCalib method averaged 14.0 s (range 3.5 s-22.7 s). We developed and validated a prototype for fast calibration and evaluation of EM tracked conventional (forward viewing) laparoscopes. The calibration method achieved acceptable accuracy and was relatively fast and easy to be performed in the OR on demand.

  20. Television imaging system for fast neutron radiography using baby cyclotron

    International Nuclear Information System (INIS)

    Yoshii, Koji; Miya, Kenzo; Katoh, Norihiko.

    1993-01-01

    A television imaging system for fast neutron radiography (FNR-TV) developed using the fast neutron source reactor YAYOI was applied to the baby-cyclotron based fast neutron source to get images of thick objects quickly. In the system the same technique as a current television imaging system of thermal neutron radiography was applied, while the luminescent converter was used to detect fast neutrons. Using the CR39 track etch method it took about 7 h to get an image, while the FNR-TV only 20 s enough for taking the same object. However the FNR-TV imaging result of the simulation model of a large explosive device for the space launch vehicle of H-2 type was not so good as the image taken with the CR39 track etch method. The reason was that the luminescence intensity of the FNR-TV converter was a quarter of that in the YAYOI. (author)

  1. Hospital Medicine Resident Training Tracks: Developing the Hospital Medicine Pipeline.

    Science.gov (United States)

    Sweigart, Joseph R; Tad-Y, Darlene; Kneeland, Patrick; Williams, Mark V; Glasheen, Jeffrey J

    2017-03-01

    Hospital medicine (HM) is rapidly evolving into new clinical and nonclinical roles. Traditional internal medicine (IM) residency training likely does not optimally prepare residents for success in HM. Hospital medicine residency training tracks may offer a preferred method for specialized HM education. Internet searches and professional networks were used to identify HM training tracks. Information was gathered from program websites and discussions with track directors. The 11 HM tracks at academic medical centers across the United States focus mostly on senior residents. Track structure and curricular content are determined largely by the structure and curricula of the IM residency programs in which they exist. Almost all tracks feature experiential quality improvement projects. Content on healthcare economics and value is common, and numerous track leaders report this content is expanding from HM tracks into entire residency programs. Tracks also provide opportunities for scholarship and professional development, such as workshops on abstract creation and job procurement skills. Almost all tracks include HM preceptorships as well as rotations within various disciplines of HM. HM residency training tracks focus largely on quality improvement, health care economics, and professional development. The structures and curricula of these tracks are tightly linked to opportunities within IM residency programs. As HM continues to evolve, these tracks likely will expand to bridge clinical and extra-clinical gaps between traditional IM training and contemporary HM practice. Journal of Hospital Medicine 2017;12:173-176. © 2017 Society of Hospital Medicine

  2. Chemical etching studies of a Brazilian polycarbonate to fast neutron detection

    International Nuclear Information System (INIS)

    Souto, E.B.; Campos, L.L.

    2006-01-01

    The Dosimetric Materials Laboratory (LMD) of the Radiation Metrology Center (CMR) is developing a personal dosimeter for fast neutrons using the technique of solid state nuclear track detectors (SSNTD). This technique is based on the recorded damage (tracks) in dielectric materials due to the impact of charged particles. The tracks are revealed and amplified for visualization in optic microscope through a technique known as chemical etching. The LMD is investigating a Brazilian commercial polycarbonate as a new passive fast neutron's detector in substitution to the traditional materials, as the cellulose nitrate LR-115 and the polycarbonates Makrofol and CR-39. The variation of the etching parameters (chemical solution, time and temperature) alters the response of the material; the best revelation conditions provide the best relationship among the amount of revealed tracks, their clearness and the time spent for this. The polycarbonate studied is a resin of same chemical monomer of Makrofol (C,6H,403). Samples of 3 x 1 cm 2 of the polycarbonate were irradiated with 5 mSv of fast neutrons ( 241 Am-Be) and revealed with the chemical solution PEW-40 (15% KOH, 45% H 2 O, 40% C 2 H 5 OH), commonly used for Makrofol. The studied etching parameters were time and temperature. Groups of four samples were revealed at temperatures of 50, 65, 75, 90 and 100 C with etching times varying from one to six hours. The used track's counting procedure was that referred in the literature. The best response to fast neutrons was obtained at 75 C; in spite of their similar answers, smaller temperatures join larger uncertainties in the track's counting and poorer clearness. At this temperature, the number of revealed tracks increases with the etching time approximately until a plateau at three hours. For etching times higher than four hours the polycarbonate presents overlap of tracks. If the temperature is adjusted to 75 C, the etching time should be in the plateau to avoid that small

  3. The performance of the γ-ray tracking array GRETINA for γ-ray spectroscopy with fast beams of rare isotopes

    International Nuclear Information System (INIS)

    Weisshaar, D.; Bazin, D.; Bender, P.C.; Campbell, C.M.; Recchia, F.; Bader, V.; Baugher, T.; Belarge, J.; Carpenter, M.P.; Crawford, H.L.; Cromaz, M.; Elman, B.; Fallon, P.; Forney, A.; Gade, A.

    2017-01-01

    The γ-ray tracking array GRETINA was coupled to the S800 magnetic spectrometer for spectroscopy with fast beams of rare isotopes at the National Superconducting Cyclotron Laboratory on the campus of Michigan State University. We describe the technical details of this powerful setup and report on GRETINA's performance achieved with source and in-beam measurements. The γ-ray multiplicity encountered in experiments with fast beams is usually low, allowing for a simplified and efficient treatment of the data in the γ-ray analysis in terms of Doppler reconstruction and spectral quality. The results reported in this work were obtained from GRETINA consisting of 8 detector modules hosting four high-purity germanium crystals each. Currently, GRETINA consists of 10 detector modules.

  4. The performance of the γ-ray tracking array GRETINA for γ-ray spectroscopy with fast beams of rare isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Weisshaar, D., E-mail: weisshaar@nscl.msu.edu [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Bazin, D. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Bender, P.C. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Campbell, C.M. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Recchia, F. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Bader, V.; Baugher, T. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Belarge, J. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Carpenter, M.P. [Argonne National Laboratory, Argonne, IL 60439 (United States); Crawford, H.L.; Cromaz, M. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Elman, B. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Fallon, P. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Forney, A. [Department of Chemistry and Biochemistry, University of Maryland, College Park, MD 20742 (United States); Gade, A. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); and others

    2017-03-01

    The γ-ray tracking array GRETINA was coupled to the S800 magnetic spectrometer for spectroscopy with fast beams of rare isotopes at the National Superconducting Cyclotron Laboratory on the campus of Michigan State University. We describe the technical details of this powerful setup and report on GRETINA's performance achieved with source and in-beam measurements. The γ-ray multiplicity encountered in experiments with fast beams is usually low, allowing for a simplified and efficient treatment of the data in the γ-ray analysis in terms of Doppler reconstruction and spectral quality. The results reported in this work were obtained from GRETINA consisting of 8 detector modules hosting four high-purity germanium crystals each. Currently, GRETINA consists of 10 detector modules.

  5. Testbeam results of the first real-time embedded tracking system with artificial retina

    Energy Technology Data Exchange (ETDEWEB)

    Neri, N., E-mail: nicola.neri@mi.infn.it; Abba, A.; Caponio, F.; Citterio, M.; Coelli, S.; Fu, J.; Merli, A.; Monti, M.; Petruzzo, M.

    2017-02-11

    We present the testbeam results of the first real-time embedded tracking system based on artificial retina algorithm. The tracking system prototype is capable of fast track reconstruction with a latency of the response below 1 μs and track parameter resolutions that are comparable with the offline results. The artificial retina algorithm was implemented in hardware in a custom data acquisition board based on commercial FPGA. The system was tested successfully using a 180 GeV/c proton beam at the CERN SPS with a maximum track rate of about 280 kHz. Online track parameters were found in good agreement with offline results and with the simulated response. - Highlights: • First real-time tracking system based on artificial retina algorithm tested on beam. • Fast track reconstruction within one microsecond latency and offline like quality. • Fast tracking algorithm implemented in commercial FPGAs.

  6. Development of intelligent MPPT (maximum power point tracking) control for a grid-connected hybrid power generation system

    International Nuclear Information System (INIS)

    Hong, Chih-Ming; Ou, Ting-Chia; Lu, Kai-Hung

    2013-01-01

    A hybrid power control system is proposed in the paper, consisting of solar power, wind power, and a diesel-engine. To achieve a fast and stable response for the real power control, an intelligent controller was proposed, which consists of the Wilcoxon (radial basis function network) RBFN and the improved (Elman neural network) ENN for (maximum power point tracking) MPPT. The pitch angle control of wind power uses improved ENN controller, and the output is fed to the wind turbine to achieve the MPPT. The solar array is integrated with an RBFN control algorithm to track the maximum power. MATLAB (MATrix LABoratory)/Simulink was used to build the dynamic model and simulate the solar and diesel-wind hybrid power system. - Highlights: ► To achieve a fast and stable response for the real power control. ► The pitch control of wind power uses improved ENN (Elman neural network) controller to achieve the MPPT (maximum power point tracking). ► The RBFN (radial basis function network) can quickly and accurately track the maximum power output for PV (photovoltaic) array. ► MATLAB was used to build the dynamic model and simulate the hybrid power system. ► This method can reach the desired performance even under different load conditions

  7. Observer-based linear parameter varying H∞ tracking control for hypersonic vehicles

    Directory of Open Access Journals (Sweden)

    Yiqing Huang

    2016-11-01

    Full Text Available This article aims to develop observer-based linear parameter varying output feedback H∞ tracking controller for hypersonic vehicles. Due to the complexity of an original nonlinear model of the hypersonic vehicle dynamics, a slow–fast loop linear parameter varying polytopic model is introduced for system stability analysis and controller design. Then, a state observer is developed by linear parameter varying technique in order to estimate the unmeasured attitude angular for slow loop system. Also, based on the designed linear parameter varying state observer, a kind of attitude tracking controller is presented to reduce tracking errors for all bounded reference attitude angular inputs. The closed-loop linear parameter varying system is proved to be quadratically stable by Lypapunov function technique. Finally, simulation results show that the developed linear parameter varying H∞ controller has good tracking capability for reference commands.

  8. Small Orbital Stereo Tracking Camera Technology Development

    Science.gov (United States)

    Gagliano, L.; Bryan, T.; MacLeod, T.

    On-Orbit Small Debris Tracking and Characterization is a technical gap in the current National Space Situational Awareness necessary to safeguard orbital assets and crew. This poses a major risk of MOD damage to ISS and Exploration vehicles. In 2015 this technology was added to NASAs Office of Chief Technologist roadmap. For missions flying in or assembled in or staging from LEO, the physical threat to vehicle and crew is needed in order to properly design the proper level of MOD impact shielding and proper mission design restrictions. Need to verify debris flux and size population versus ground RADAR tracking. Use of ISS for In-Situ Orbital Debris Tracking development provides attitude, power, data and orbital access without a dedicated spacecraft or restricted operations on-board a host vehicle as a secondary payload. Sensor Applicable to in-situ measuring orbital debris in flux and population in other orbits or on other vehicles. Could enhance safety on and around ISS. Some technologies extensible to monitoring of extraterrestrial debris as well To help accomplish this, new technologies must be developed quickly. The Small Orbital Stereo Tracking Camera is one such up and coming technology. It consists of flying a pair of intensified megapixel telephoto cameras to evaluate Orbital Debris (OD) monitoring in proximity of International Space Station. It will demonstrate on-orbit optical tracking (in situ) of various sized objects versus ground RADAR tracking and small OD models. The cameras are based on Flight Proven Advanced Video Guidance Sensor pixel to spot algorithms (Orbital Express) and military targeting cameras. And by using twin cameras we can provide Stereo images for ranging & mission redundancy. When pointed into the orbital velocity vector (RAM), objects approaching or near the stereo camera set can be differentiated from the stars moving upward in background.

  9. Tracking Clean Energy Progress 2013

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-06-01

    Tracking Clean Energy Progress 2013 (TCEP 2013) examines progress in the development and deployment of key clean energy technologies. Each technology and sector is tracked against interim 2020 targets in the IEA Energy Technology Perspectives 2012 2°C scenario, which lays out pathways to a sustainable energy system in 2050. Stark message emerge: progress has not been fast enough; large market failures are preventing clean energy solutions from being taken up; considerable energy efficiency remains untapped; policies need to better address the energy system as a whole; and energy-related research, development and demonstration need to accelerate. Alongside these grim conclusions there is positive news. In 2012, hybrid-electric vehicle sales passed the 1 million mark. Solar photovoltaic systems were being installed at a record pace. The costs of most clean energy technologies fell more rapidly than anticipated.

  10. Radiation-hardened fast acquisition/weak signal tracking system and method

    Science.gov (United States)

    Winternitz, Luke (Inventor); Boegner, Gregory J. (Inventor); Sirotzky, Steve (Inventor)

    2009-01-01

    A global positioning system (GPS) receiver and method of acquiring and tracking GPS signals comprises an antenna adapted to receive GPS signals; an analog radio frequency device operatively connected to the antenna and adapted to convert the GPS signals from an analog format to a digital format; a plurality of GPS signal tracking correlators operatively connected to the analog RF device; a GPS signal acquisition component operatively connected to the analog RF device and the plurality of GPS signal tracking correlators, wherein the GPS signal acquisition component is adapted to calculate a maximum vector on a databit correlation grid; and a microprocessor operatively connected to the plurality of GPS signal tracking correlators and the GPS signal acquisition component, wherein the microprocessor is adapted to compare the maximum vector with a predetermined correlation threshold to allow the GPS signal to be fully acquired and tracked.

  11. A Hardware Fast Tracker for the ATLAS Trigger: The Fast TracKer (FTK) Project.

    CERN Document Server

    Asbah, Nedaa; The ATLAS collaboration

    2015-01-01

    The trigger system of the ATLAS experiment is designed to reduce the event rate from the LHC nominal bunch crossing at 40 MHz to about 1 kHz, at the design luminosity of 10^{34} cm^{-2} s{-1}. After a successful period of data taking from 2010 to early 2013, the LHC is restarting in 2015 with much higher instantaneous luminosity and this will increase the load on High Level Trigger system, the second stage of the selection based on software algorithms. More sophisticated algorithms will be needed to achieve higher background rejection while maintaining good efficiency for interesting physics signals. The Fast TracKer is part of the ATLAS trigger upgrade project; it is a hardware processor that will provide, at every level-1 accept (100 kHz) and within 100 microseconds, full tracking information for tracks with momentum as low as 1 GeV. Providing fast extensive access to tracking information, with resolution comparable to the offline reconstruction, the Fast Tracker will for example help the High Level Trigger...

  12. Fast cine-magnetic resonance imaging point tracking for prostate cancer radiation therapy planning

    International Nuclear Information System (INIS)

    Dowling, J; Chandra, S; Dang, K; Fox, Chris D; Gill, Suki; Kron, T; Pham, D; Foroudi, F

    2014-01-01

    The analysis of intra-fraction organ motion is important for improving the precision of radiation therapy treatment delivery. One method to quantify this motion is for one or more observers to manually identify anatomic points of interest (POIs) on each slice of a cine-MRI sequence. However this is labour intensive and inter- and intra- observer variation can introduce uncertainty. In this paper a fast method for non-rigid registration based point tracking in cine-MRI sagittal and coronal series is described which identifies POIs in 0.98 seconds per sagittal slice and 1.35 seconds per coronal slice. The manual and automatic points were highly correlated (r>0.99, p<0.001) for all organs and the difference generally less than 1mm. For prostate planning peristalsis and rectal gas can result in unpredictable out of plane motion, suggesting the results may require manual verification.

  13. Fast track in total hip and knee arthroplasty--experiences from Hvidovre University Hospital, Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte

    2006-01-01

    This study investigated whether unselected patients operated on with total hip arthroplasty (THA) or total knee arthroplasty (TKA) could accomplish a self-developed accelerated track, ANORAK-HH, with a planned length of stay (LOS) of maximum 5 days and patient satisfaction at all parts of the track...... and a planned LOS of maximum 5 days. 22 patient characteristics and 11 satisfaction parameters were registered as well as readmissions within 3 months. 95% of patients had a LOS of maximum 5 days with a mean of 3.9 days. Median and mean values of satisfaction for the entire track were 10 and 9.4 out of 10...

  14. Imaging of fast-neutron sources using solid-state track-recorder pinhole radiography

    International Nuclear Information System (INIS)

    Ruddy, F.H.; Gold, R.; Roberts, J.H.; Kaiser, B.J.; Preston, C.C.

    1983-08-01

    Pinhole imaging methods are being developed and tested for potential future use in imaging the intense neutron source of the Fusion Materials Irradiation Test (FMIT) Facility. Previously reported, extensive calibration measurements of the proton, neutron, and alpha particle response characteristics of CR-39 polymer solid state track recorders (SSTRs) are being used to interpret the results of imaging experiments using both charged particle and neutron pinhole collimators. High resolution, neutron pinhole images of a 252 Cf source have been obtained in the form of neutron induced proton recoil tracks in CR-39 polymer SSTR. These imaging experiments are described as well as their potential future applications to FMIT

  15. Status of the DEBENE fast breeder reactor development, March 1979

    International Nuclear Information System (INIS)

    Daeunert, U.; Kessler, G.

    1979-01-01

    Status report of the Fast-breeder reactor development in Germany covers the following: description of the political situation in Federal republic of germany during 1978; international cooperation in the field of fast reactor technology development; operation description of the KNK-II fast core experimental power plant; status of construction of the SNR-300; results of the research and development programs concerned with fuel element, cladding, absorber rods and core structural materials development; sodium effects; neutron irradiation effects on SS properties; reactor physics related to experiments in fast critical assemblies; fast reactor safety issues; core disruption accidents; sodium boiling experiments, measuring methods developed; component tests

  16. Status of the DEBENE fast breeder reactor development, March 1979

    Energy Technology Data Exchange (ETDEWEB)

    Daeunert, U; Kessler, G

    1979-07-01

    Status report of the Fast-breeder reactor development in Germany covers the following: description of the political situation in Federal republic of germany during 1978; international cooperation in the field of fast reactor technology development; operation description of the KNK-II fast core experimental power plant; status of construction of the SNR-300; results of the research and development programs concerned with fuel element, cladding, absorber rods and core structural materials development; sodium effects; neutron irradiation effects on SS properties; reactor physics related to experiments in fast critical assemblies; fast reactor safety issues; core disruption accidents; sodium boiling experiments, measuring methods developed; component tests.

  17. The CDF II eXtremely fast tracker upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Abulencia, A.; Azzurri, P.; Cochran, E.; Dittmann, J.; Donati, S.; Efron, J.; Erbacher, R.; Errede, D.; Fedorko, I.; Flanagan, G.; Forrest, R.; /Illinois U., Urbana

    2006-09-01

    The CDF II Extremely Fast Tracker is the trigger track processor which reconstructs charged particle tracks in the transverse plane of the CDF II central outer tracking chamber. The system is now being upgraded to perform a three dimensional track reconstruction. A review of the upgrade is presented here.

  18. Study of hardware implementations of fast tracking algorithms

    International Nuclear Information System (INIS)

    Song, Z.; Huang, G.; Wang, D.; Lentdecker, G. De; Dong, J.; Léonard, A.; Robert, F.; Yang, Y.

    2017-01-01

    Real-time track reconstruction at high event rates is a major challenge for future experiments in high energy physics. To perform pattern-recognition and track fitting, artificial retina or Hough transformation methods have been introduced in the field which have to be implemented in FPGA firmware. In this note we report on a case study of a possible FPGA hardware implementation approach of the retina algorithm based on a Floating-Point core. Detailed measurements with this algorithm are investigated. Retina performance and capabilities of the FPGA are discussed along with perspectives for further optimization and applications.

  19. Evaluation of the influence of pulmonary hypertension in ultra-fast-track anesthesia technique in adult patients undergoing cardiac surgery

    Directory of Open Access Journals (Sweden)

    Paulo Sérgio da Silva

    2015-08-01

    Full Text Available Abstract Objective: To evaluate the influence of pulmonary hypertension in the ultra-fast-track anesthesia technique in adult cardiac surgery. Methods: A retrospective study. They were included 40 patients divided into two groups: GI (without pulmonary hypertension and GII (with pulmonary hypertension. Based on data obtained by transthoracic echocardiography. We considered as the absence of pulmonary hypertension: a pulmonary artery systolic pressure (sPAP 40 mmHg associated with additional echocardiographic signs of PH. It was established as influence of pulmonary hypertension: the impossibility of extubation in the operating room, the increase in the time interval for extubation and reintubation the first 24 hours postoperatively. Univariate and multivariate analyzes were performed when necessary. Considered significant a P value <0.05. Results: The GI was composed of 21 patients and GII for 19. All patients (100% were extubated in the operating room in a medium time interval of 17.58±8.06 min with a median of 18 min in GII and 17 min in GI. PH did not increase the time interval for extubation (P=0.397. It required reintubation of 2 patients in GII (5% of the total, without statistically significant as compared to GI (P=0.488. Conclusion: In this study, pulmonary hypertension did not influence on ultra-fast-track anesthesia in adult cardiac surgery.

  20. The fast tracker processor for hadronic collider triggers

    CERN Document Server

    Annovi, A; Bardi, A; Carosi, R; Dell'Orso, Mauro; D'Onofrio, M; Giannetti, P; Iannaccone, G; Morsani, F; Pietri, M; Varotto, G

    2000-01-01

    Perspective for precise and fast track reconstruction in future hadronic collider experiments are addressed. We discuss the feasibility of a pipelined highly parallelized processor dedicated to the implementation of a very fast algorithm. The algorithm is based on the use of a large bank of pre-stored combinations of trajectory points (patterns) for extremely complex tracking systems. The CMS experiment at LHC is used as a benchmark. Tracking data from the events selected by the level-1 trigger are sorted and filtered by the Fast Tracker processor at a rate of 100 kHz. This data organization allows the level-2 trigger logic to reconstruct full resolution traces with transverse momentum above few GeV and search secondary vertexes within typical level-2 times. 15 Refs.

  1. Detection of a faint fast-moving near-Earth asteroid using the synthetic tracking technique

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, Chengxing; Shao, Michael; Nemati, Bijan; Werne, Thomas; Zhou, Hanying; Turyshev, Slava G.; Sandhu, Jagmit [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States); Hallinan, Gregg; Harding, Leon K., E-mail: chengxing.zhai@jpl.nasa.gov [Department of Astronomy, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 (United States)

    2014-09-01

    We report a detection of a faint near-Earth asteroid (NEA) using our synthetic tracking technique and the CHIMERA instrument on the Palomar 200 inch telescope. With an apparent magnitude of 23 (H = 29, assuming detection at 20 lunar distances), the asteroid was moving at 6.°32 day{sup –1} and was detected at a signal-to-noise ratio (S/N) of 15 using 30 s of data taken at a 16.7 Hz frame rate. The detection was confirmed by a second observation 77 minutes later at the same S/N. Because of its high proper motion, the NEA moved 7 arcsec over the 30 s of observation. Synthetic tracking avoided image degradation due to trailing loss that affects conventional techniques relying on 30 s exposures; the trailing loss would have degraded the surface brightness of the NEA image on the CCD down to an approximate magnitude of 25 making the object undetectable. This detection was a result of our 12 hr blind search conducted on the Palomar 200 inch telescope over two nights, scanning twice over six (5.°3 × 0.°046) fields. Detecting only one asteroid is consistent with Harris's estimates for the distribution of the asteroid population, which was used to predict a detection of 1.2 NEAs in the H-magnitude range 28-31 for the two nights. The experimental design, data analysis methods, and algorithms are presented. We also demonstrate milliarcsecond-level astrometry using observations of two known bright asteroids on the same system with synthetic tracking. We conclude by discussing strategies for scheduling observations to detect and characterize small and fast-moving NEAs using the new technique.

  2. Getting on the fast track, or how to get an MLIS through distance education, with a specialization in medical librarianship.

    Science.gov (United States)

    Detlefsen, Ellen G

    2004-01-01

    The article describes an innovation in MLIS education for medical librarianship, with an introduction to the FastTrack, the distance education program at the University of Pittsburgh's library and information science school, together with an overview of a model program linking the biomedical library at Vanderbilt University with the School of Information Sciences in Pittsburgh. Admissions requirements and specific curriculum for the distance education master's degree are detailed in an FAQ format.

  3. Chemical etching studies of a Brazilian polycarbonate to fast neutron detection

    Energy Technology Data Exchange (ETDEWEB)

    Souto, E.B.; Campos, L.L. [Instituto de Pesquisas Energeticas e Nucleares, IPEN- CNEN/SP Radiation Metrology Center (CMR) Av. Prof. Lineu Prestes, 2242 CEP: 05508-000 Sao Paulo - SP (Brazil)]. e-mail: ebsouto@ipen.br

    2006-07-01

    The Dosimetric Materials Laboratory (LMD) of the Radiation Metrology Center (CMR) is developing a personal dosimeter for fast neutrons using the technique of solid state nuclear track detectors (SSNTD). This technique is based on the recorded damage (tracks) in dielectric materials due to the impact of charged particles. The tracks are revealed and amplified for visualization in optic microscope through a technique known as chemical etching. The LMD is investigating a Brazilian commercial polycarbonate as a new passive fast neutron's detector in substitution to the traditional materials, as the cellulose nitrate LR-115 and the polycarbonates Makrofol and CR-39. The variation of the etching parameters (chemical solution, time and temperature) alters the response of the material; the best revelation conditions provide the best relationship among the amount of revealed tracks, their clearness and the time spent for this. The polycarbonate studied is a resin of same chemical monomer of Makrofol (C,6H,403). Samples of 3 x 1 cm{sup 2} of the polycarbonate were irradiated with 5 mSv of fast neutrons ({sup 241}Am-Be) and revealed with the chemical solution PEW-40 (15% KOH, 45% H{sub 2}O, 40% C{sub 2}H{sub 5}OH), commonly used for Makrofol. The studied etching parameters were time and temperature. Groups of four samples were revealed at temperatures of 50, 65, 75, 90 and 100 C with etching times varying from one to six hours. The used track's counting procedure was that referred in the literature. The best response to fast neutrons was obtained at 75 C; in spite of their similar answers, smaller temperatures join larger uncertainties in the track's counting and poorer clearness. At this temperature, the number of revealed tracks increases with the etching time approximately until a plateau at three hours. For etching times higher than four hours the polycarbonate presents overlap of tracks. If the temperature is adjusted to 75 C, the etching time should be in

  4. Positron emission zone plate holography for particle tracking

    Energy Technology Data Exchange (ETDEWEB)

    Gundogdu, O. [University of Birmingham, School of Physics and Astronomy, Birmingham B15 2TT (United Kingdom)]. E-mail: o.gundogdu@surrey.ac.uk

    2006-01-15

    Positron Emission Particle Tracking (PEPT) is a powerful non-invasive technique that has been used extensively for tracking a single particle. In this paper, we present a study of zone plate holography method in order to track multiple particles, mainly two particles. The main aim is to use as small number of events as possible in the order to make it possible to track particles in fast moving industrial systems. A zone plate with 100% focal efficiency is simulated and applied to the Positron Emission Tomography (PET) data for multiple particle tracking. A simple trajectory code was employed to explore the effects of the nature of the experimental trajectories. A computer holographic reconstruction code that simulates optical reconstruction was developed. The different aspects of the particle location, particle activity ratios for enabling tagging of particles and zone plate and hologram locations are investigated. The effect of the shot noise is investigated and the limitations of the zone plate holography are reported.

  5. Positron emission zone plate holography for particle tracking

    International Nuclear Information System (INIS)

    Gundogdu, O.

    2006-01-01

    Positron Emission Particle Tracking (PEPT) is a powerful non-invasive technique that has been used extensively for tracking a single particle. In this paper, we present a study of zone plate holography method in order to track multiple particles, mainly two particles. The main aim is to use as small number of events as possible in the order to make it possible to track particles in fast moving industrial systems. A zone plate with 100% focal efficiency is simulated and applied to the Positron Emission Tomography (PET) data for multiple particle tracking. A simple trajectory code was employed to explore the effects of the nature of the experimental trajectories. A computer holographic reconstruction code that simulates optical reconstruction was developed. The different aspects of the particle location, particle activity ratios for enabling tagging of particles and zone plate and hologram locations are investigated. The effect of the shot noise is investigated and the limitations of the zone plate holography are reported

  6. Decontaminate feature for tracking: adaptive tracking via evolutionary feature subset

    Science.gov (United States)

    Liu, Qiaoyuan; Wang, Yuru; Yin, Minghao; Ren, Jinchang; Li, Ruizhi

    2017-11-01

    Although various visual tracking algorithms have been proposed in the last 2-3 decades, it remains a challenging problem for effective tracking with fast motion, deformation, occlusion, etc. Under complex tracking conditions, most tracking models are not discriminative and adaptive enough. When the combined feature vectors are inputted to the visual models, this may lead to redundancy causing low efficiency and ambiguity causing poor performance. An effective tracking algorithm is proposed to decontaminate features for each video sequence adaptively, where the visual modeling is treated as an optimization problem from the perspective of evolution. Every feature vector is compared to a biological individual and then decontaminated via classical evolutionary algorithms. With the optimized subsets of features, the "curse of dimensionality" has been avoided while the accuracy of the visual model has been improved. The proposed algorithm has been tested on several publicly available datasets with various tracking challenges and benchmarked with a number of state-of-the-art approaches. The comprehensive experiments have demonstrated the efficacy of the proposed methodology.

  7. 4D tracking with ultra-fast silicon detectors

    Science.gov (United States)

    F-W Sadrozinski, Hartmut; Seiden, Abraham; Cartiglia, Nicolò

    2018-02-01

    The evolution of particle detectors has always pushed the technological limit in order to provide enabling technologies to researchers in all fields of science. One archetypal example is the evolution of silicon detectors, from a system with a few channels 30 years ago, to the tens of millions of independent pixels currently used to track charged particles in all major particle physics experiments. Nowadays, silicon detectors are ubiquitous not only in research laboratories but in almost every high-tech apparatus, from portable phones to hospitals. In this contribution, we present a new direction in the evolution of silicon detectors for charge particle tracking, namely the inclusion of very accurate timing information. This enhancement of the present silicon detector paradigm is enabled by the inclusion of controlled low gain in the detector response, therefore increasing the detector output signal sufficiently to make timing measurement possible. After providing a short overview of the advantage of this new technology, we present the necessary conditions that need to be met for both sensor and readout electronics in order to achieve 4D tracking. In the last section, we present the experimental results, demonstrating the validity of our research path.

  8. FAST scanning in the developing world emergency department ...

    African Journals Online (AJOL)

    FAST scanning in the developing world emergency department. ZA Smith, N Postma, D Wood. Abstract. Objectives. To assess the utility of an existing ultrasound machine for the purposes of focused assessment sonography in trauma (FAST) scanning in a developing world emergency department (ED). Design. Prospective ...

  9. Comparison of ergometer- and track-based testing in junior track-sprint cyclists. Implications for talent identification and development.

    Science.gov (United States)

    Tofari, Paul J; Cormack, Stuart J; Ebert, Tammie R; Gardner, A Scott; Kemp, Justin G

    2017-10-01

    Talent identification (TID) and talent development (TDE) programmes in track sprint cycling use ergometer- and track-based tests to select junior athletes and assess their development. The purpose of this study was to assess which tests are best at monitoring TID and TDE. Ten male participants (16.2 ± 1.1 year; 178.5 ± 6.0 cm and 73.6 ± 7.6 kg) were selected into the national TID squad based on initial testing. These tests consisted of two 6-s maximal sprints on a custom-built ergometer and 4 maximal track-based tests (2 rolling and 2 standing starts) using 2 gear ratios. Magnitude-based inferences and correlation coefficients assessed changes following a 3-month TDE programme. Training elicited meaningful improvements (80-100% likely) in all ergometer parameters. The standing and rolling small gear, track-based effort times were likely and very likely (3.2 ± 2.4% and 3.3 ± 1.9%, respectively) improved by training. Stronger correlations between ergometer- and track-based measures were very likely following training. Ergometer-based testing provides a more sensitive tool than track-based testing to monitor changes in neuromuscular function during the early stages of TDE. However, track-based testing can indicate skill-based improvements in performance when interpreted with ergometer testing. In combination, these tests provide information on overall talent development.

  10. CATS: a cellular automaton for tracking in silicon for the HERA-B vertex detector

    International Nuclear Information System (INIS)

    Abt, I.; Emeliyanov, D.; Kisel, I.; Masciocchi, S.

    2002-01-01

    The new track reconstruction program CATS developed for the Vertex Detector System of the HERA-B experiment at DESY is presented. It employs a cellular automaton for track searching and the Kalman filter for track fitting. This results in a very fast algorithm that combines highly efficient track recognition with accurate and reliable track parameter estimation. To reduce the computational cost of the fit an optimized numerical implementation of the Kalman filter is used. Alternative approaches to the track reconstruction in the VDS are also discussed. Since 1999, after extensive tests on simulated data, CATS has been employed to reconstruct experimental data collected in HERA-B. Results regarding tracking performance, the accuracy of track parameter estimates and CPU time consumption are presented

  11. Tracking by Machine Learning Methods

    CERN Document Server

    Jofrehei, Arash

    2015-01-01

    Current track reconstructing methods start with two points and then for each layer loop through all possible hits to find proper hits to add to that track. Another idea would be to use this large number of already reconstructed events and/or simulated data and train a machine on this data to find tracks given hit pixels. Training time could be long but real time tracking is really fast Simulation might not be as realistic as real data but tacking has been done for that with 100 percent efficiency while by using real data we would probably be limited to current efficiency.

  12. Object Tracking via 2DPCA and l2-Regularization

    Directory of Open Access Journals (Sweden)

    Haijun Wang

    2016-01-01

    Full Text Available We present a fast and robust object tracking algorithm by using 2DPCA and l2-regularization in a Bayesian inference framework. Firstly, we model the challenging appearance of the tracked object using 2DPCA bases, which exploit the strength of subspace representation. Secondly, we adopt the l2-regularization to solve the proposed presentation model and remove the trivial templates from the sparse tracking method which can provide a more fast tracking performance. Finally, we present a novel likelihood function that considers the reconstruction error, which is concluded from the orthogonal left-projection matrix and the orthogonal right-projection matrix. Experimental results on several challenging image sequences demonstrate that the proposed method can achieve more favorable performance against state-of-the-art tracking algorithms.

  13. Fast neutron personnel dosimetry by CR-39 plastics a new electrochemical etching procedure

    International Nuclear Information System (INIS)

    Djeffal, S.

    1984-07-01

    In the first part of this work a brief description of solid state nuclear track detectors, the principles of track registration and the different reading techniques are given. In the experimental part of the present work we systematically analysed different etching procedures and set a new electrochemical etching method, which enables us to develop a new fast neutron dosimeter. This fast neutron dosimeter makes possible the measurement of low neutron doses in the energy range from 10 Kev to 20 Mev with a reasonably flat energy response. These new developments are very attractive in personnel neutron dosimetry where nuclear emulsions are still used despite their insensitivity to neutron energies down to 500 Kev (i.e. the energy range one often encounters around nuclear facilities)

  14. Possibilities of fast track surgery principles in the treatment of congenital urological anomalies

    Directory of Open Access Journals (Sweden)

    Bižić Marta R.

    2012-01-01

    Full Text Available Introduction. Urogenital congenital anomalies are among the most common congenital anomalies and very frequent pathology in paediatric urology. Health care systems strive to shorten the duration and reduce the costs of hospitalization, while maintaining treatment effectiveness. Objective. To evaluate the duration of hospital stay of surgically treated patients with congenital urogenital anomalies and estimate the possibility of using fast track surgery principles in paediatric urology in the local settings of a developing country. Methods. Retrospective non-randomized study included 552 patients who had been surgically treated at the Urology Department of the University Children’s Hospital, during 2010. In line with their congenital anomalies, all patients were classified in one of four groups: I - upper urinary tract anomalies (252 patients; II - genital anomalies (164 patients; III - testicular anomalies (76 patients and IV - associated anomalies (60 patients. We analyzed the total duration of stay as well as preand post-operative stay in the hospital. Results. The average duration of hospitalization was 4.7±4.0 days. Patients with testicular anomalies stayed for the shortest period (2.3±1.9 days (p<0.01 and patients with associated anomalies stayed in the hospital the longest (6.5±4.7 days (p<0.01. Conclusion. Modern methods of surgical treatment allow reduction of hospitalization, financial savings to the healthcare system and greater comfort for patients. Our results showed that this is also possible to apply in our environment.

  15. Study Protocol: Phase III single-blinded fast-track pragmatic randomised controlled trial of a complex intervention for breathlessness in advanced disease

    Directory of Open Access Journals (Sweden)

    Brafman-Kennedy Barbara

    2011-05-01

    Full Text Available Abstract Background Breathlessness in advanced disease causes significant distress to patients and carers and presents management challenges to health care professionals. The Breathlessness Intervention Service (BIS seeks to improve the care of breathless patients with advanced disease (regardless of cause through the use of evidence-based practice and working with other healthcare providers. BIS delivers a complex intervention (of non-pharmacological and pharmacological treatments via a multi-professional team. BIS is being continuously developed and its impact evaluated using the MRC's framework for complex interventions (PreClinical, Phase I and Phase II completed. This paper presents the protocol for Phase III. Methods/Design Phase III comprises a pragmatic, fast-track, single-blind randomised controlled trial of BIS versus standard care. Due to differing disease trajectories, the service uses two broad service models: one for patients with malignant disease (intervention delivered over two weeks and one for patients with non-malignant disease (intervention delivered over four weeks. The Phase III trial therefore consists of two sub-protocols: one for patients with malignant conditions (four week protocol and one for patients with non-malignant conditions (eight week protocol. Mixed method interviews are conducted with patients and their lay carers at three to five measurement points depending on randomisation and sub-protocol. Qualitative interviews are conducted with referring and non-referring health care professionals (malignant disease protocol only. The primary outcome measure is 'patient distress due to breathlessness' measured on a numerical rating scale (0-10. The trial includes economic evaluation. Analysis will be on an intention to treat basis. Discussion This is the first evaluation of a breathlessness intervention for advanced disease to have followed the MRC framework and one of the first palliative care trials to use fast

  16. Development of Robust Behaviour Recognition for an at-Home Biomonitoring Robot with Assistance of Subject Localization and Enhanced Visual Tracking

    Science.gov (United States)

    Imamoglu, Nevrez; Dorronzoro, Enrique; Wei, Zhixuan; Shi, Huangjun; González, José; Gu, Dongyun; Yu, Wenwei

    2014-01-01

    Our research is focused on the development of an at-home health care biomonitoring mobile robot for the people in demand. Main task of the robot is to detect and track a designated subject while recognizing his/her activity for analysis and to provide warning in an emergency. In order to push forward the system towards its real application, in this study, we tested the robustness of the robot system with several major environment changes, control parameter changes, and subject variation. First, an improved color tracker was analyzed to find out the limitations and constraints of the robot visual tracking considering the suitable illumination values and tracking distance intervals. Then, regarding subject safety and continuous robot based subject tracking, various control parameters were tested on different layouts in a room. Finally, the main objective of the system is to find out walking activities for different patterns for further analysis. Therefore, we proposed a fast, simple, and person specific new activity recognition model by making full use of localization information, which is robust to partial occlusion. The proposed activity recognition algorithm was tested on different walking patterns with different subjects, and the results showed high recognition accuracy. PMID:25587560

  17. Development of Robust Behaviour Recognition for an at-Home Biomonitoring Robot with Assistance of Subject Localization and Enhanced Visual Tracking

    Directory of Open Access Journals (Sweden)

    Nevrez Imamoglu

    2014-01-01

    Full Text Available Our research is focused on the development of an at-home health care biomonitoring mobile robot for the people in demand. Main task of the robot is to detect and track a designated subject while recognizing his/her activity for analysis and to provide warning in an emergency. In order to push forward the system towards its real application, in this study, we tested the robustness of the robot system with several major environment changes, control parameter changes, and subject variation. First, an improved color tracker was analyzed to find out the limitations and constraints of the robot visual tracking considering the suitable illumination values and tracking distance intervals. Then, regarding subject safety and continuous robot based subject tracking, various control parameters were tested on different layouts in a room. Finally, the main objective of the system is to find out walking activities for different patterns for further analysis. Therefore, we proposed a fast, simple, and person specific new activity recognition model by making full use of localization information, which is robust to partial occlusion. The proposed activity recognition algorithm was tested on different walking patterns with different subjects, and the results showed high recognition accuracy.

  18. Development of robust behaviour recognition for an at-home biomonitoring robot with assistance of subject localization and enhanced visual tracking.

    Science.gov (United States)

    Imamoglu, Nevrez; Dorronzoro, Enrique; Wei, Zhixuan; Shi, Huangjun; Sekine, Masashi; González, José; Gu, Dongyun; Chen, Weidong; Yu, Wenwei

    2014-01-01

    Our research is focused on the development of an at-home health care biomonitoring mobile robot for the people in demand. Main task of the robot is to detect and track a designated subject while recognizing his/her activity for analysis and to provide warning in an emergency. In order to push forward the system towards its real application, in this study, we tested the robustness of the robot system with several major environment changes, control parameter changes, and subject variation. First, an improved color tracker was analyzed to find out the limitations and constraints of the robot visual tracking considering the suitable illumination values and tracking distance intervals. Then, regarding subject safety and continuous robot based subject tracking, various control parameters were tested on different layouts in a room. Finally, the main objective of the system is to find out walking activities for different patterns for further analysis. Therefore, we proposed a fast, simple, and person specific new activity recognition model by making full use of localization information, which is robust to partial occlusion. The proposed activity recognition algorithm was tested on different walking patterns with different subjects, and the results showed high recognition accuracy.

  19. Anesthesia and fast-track in video-assisted thoracic surgery (VATS): from evidence to practice.

    Science.gov (United States)

    Umari, Marzia; Falini, Stefano; Segat, Matteo; Zuliani, Michele; Crisman, Marco; Comuzzi, Lucia; Pagos, Francesco; Lovadina, Stefano; Lucangelo, Umberto

    2018-03-01

    In thoracic surgery, the introduction of video-assisted thoracoscopic techniques has allowed the development of fast-track protocols, with shorter hospital lengths of stay and improved outcomes. The perioperative management needs to be optimized accordingly, with the goal of reducing postoperative complications and speeding recovery times. Premedication performed in the operative room should be wisely administered because often linked to late discharge from the post-anesthesia care unit (PACU). Inhalatory anesthesia, when possible, should be preferred based on protective effects on postoperative lung inflammation. Deep neuromuscular blockade should be pursued and carefully monitored, and an appropriate reversal administered before extubation. Management of one-lung ventilation (OLV) needs to be optimized to prevent not only intraoperative hypoxemia but also postoperative acute lung injury (ALI): protective ventilation strategies are therefore to be implemented. Locoregional techniques should be favored over intravenous analgesia: the thoracic epidural, the paravertebral block (PVB), the intercostal nerve block (ICNB), and the serratus anterior plane block (SAPB) are thoroughly reviewed and the most common dosages are reported. Fluid therapy needs to be administered critically, to avoid both overload and cardiovascular compromisation. All these practices are analyzed singularly with the aid of the most recent evidences aimed at the best patient care. Finally, a few notes on some of the latest trends in research are presented, such as non-intubated video-assisted thoracoscopic surgery (VATS) and intravenous lidocaine.

  20. Track Simulation and Reconstruction in the ATLAS experiment

    CERN Document Server

    Salzburger, Andreas; Elsing, Markus

    The reconstruction and simulation of particle trajectories is an inevitable part of the analysis strate- gies for data taken with the ATLAS detector. Many aspects and necessary parts of a high-quality track reconstruction will be presented and discussed in this work. At first, the technical realisation of the data model and the reconstruction geometry will be given; the reconstruction geometry is charac- terised by a newly developed navigation model and an automated procedure for the synchronisation of the detailed simulation geometry description with the simplified reconstruction geometry model, which allows a precise description of the tracker material in track reconstruction. Both components help the coherent and fast integration of material effects in a newly established track extrapolation package, that is discussed in the following. The extrapolation engine enables a highly precise trans- port of the track parameterisation and the associated covariances through the complex magnetic field and the detec...

  1. Overview of the ATLAS Fast Tracker Project

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00025195; The ATLAS collaboration

    2016-01-01

    The next LHC runs, with a significant increase in instantaneous luminosity, will provide a big challenge for the trigger and data acquisition systems of all the experiments. An intensive use of the tracking information at the trigger level will be important to keep high efficiency for interesting events despite the increase in multiple collisions per bunch crossing. In order to increase the use of tracks within the High Level Trigger, the ATLAS experiment planned the installation of a hardware processor dedicated to tracking: the Fast TracKer processor. The Fast Tracker is designed to perform full scan track reconstruction of every event accepted by the ATLAS first level hardware trigger. To achieve this goal the system uses a parallel architecture, with algorithms designed to exploit the computing power of custom Associative Memory chips, and modern field programmable gate arrays. The processor will provide computing power to reconstruct tracks with transverse momentum greater than 1 GeV in the whole trackin...

  2. Fast algorithm of track reconstruction for the Delphy TPC

    International Nuclear Information System (INIS)

    Maillard, J.

    1984-01-01

    We describe a simple geometrical method (polar inversion) to reconstruct tracks. When the magnetic field is constant in magnitude and direction. This method uses geometrical properties of the trajectories. In the case of the DELPHI apparatus, the track reconstruction is done using TPC informations. After explaining the algorithm, we give results on ''GEANT'' simulated events using the ''Lund'' generator. Today we get a computer time of the order of 1.2 milliseconds on a CDC 7600 and an efficiency of 98% [fr

  3. Studies of avalanche photodiodes for scintillating fibre tracking readout

    International Nuclear Information System (INIS)

    Fenker, H.; Thomas, J.

    1993-01-01

    Avalanche Photodiodes (APDs) operating in ''Geiger Mode'' have been studied in a fibre tracking readout environment. A fast recharge circuit has been developed for high rate data taking, and results obtained from a model fibre tracker in the test beam at Brookhaven National Laboratory are presented. A high rate calibrated light source has been developed using a commercially available laser diode and has been used to measure the efficiency of the devices. The transmission of the light from a 1mm fibre onto a 0.5mm diameter APD surface has been identified as the main problem in the use of these particular devices for scintillating fibre tracking in the Superconducting Supercollider environment. Solutions to this problem are proposed

  4. Fast reactor fuel design and development

    International Nuclear Information System (INIS)

    Bishop, J.F.W.; Chamberlain, A.; Holmes, J.A.G.

    1977-01-01

    Fuel design parameters for oxide and carbide fast reactor fuels are reviewed in the context of minimising the total uranium demands for a combined thermal and fast reactor system. The major physical phenomena conditioning fast reactor fuel design, with a target of high burn-up, good breeding and reliable operation, are characterised. These include neutron induced void swelling, irradiation creep, pin failure modes, sub-assembly structural behaviour, behaviour of defect fuel, behaviour of alternative fuel forms. The salient considerations in the commercial scale fabrication and reprocessing of the fuels are reviewed, leading to the delineation of possible routes for the manufacture and reprocessing of Commercial Reactor fuel. From the desiderata and restraints arising from Surveys, Performance and Manufacture, the problems posed to the Designer are considered, and a narrow range of design alternatives is proposed. The paper concludes with a consideration of the development areas and the conceptual problems for fast reactors associated with those areas

  5. The ATLAS fast tracker processor design

    CERN Document Server

    Volpi, Guido; Albicocco, Pietro; Alison, John; Ancu, Lucian Stefan; Anderson, James; Andari, Nansi; Andreani, Alessandro; Andreazza, Attilio; Annovi, Alberto; Antonelli, Mario; Asbah, Needa; Atkinson, Markus; Baines, J; Barberio, Elisabetta; Beccherle, Roberto; Beretta, Matteo; Biesuz, Nicolo Vladi; Blair, R E; Bogdan, Mircea; Boveia, Antonio; Britzger, Daniel; Bryant, Partick; Burghgrave, Blake; Calderini, Giovanni; Camplani, Alessandra; Cavaliere, Viviana; Cavasinni, Vincenzo; Chakraborty, Dhiman; Chang, Philip; Cheng, Yangyang; Citraro, Saverio; Citterio, Mauro; Crescioli, Francesco; Dawe, Noel; Dell'Orso, Mauro; Donati, Simone; Dondero, Paolo; Drake, G; Gadomski, Szymon; Gatta, Mauro; Gentsos, Christos; Giannetti, Paola; Gkaitatzis, Stamatios; Gramling, Johanna; Howarth, James William; Iizawa, Tomoya; Ilic, Nikolina; Jiang, Zihao; Kaji, Toshiaki; Kasten, Michael; Kawaguchi, Yoshimasa; Kim, Young Kee; Kimura, Naoki; Klimkovich, Tatsiana; Kolb, Mathis; Kordas, K; Krizka, Karol; Kubota, T; Lanza, Agostino; Li, Ho Ling; Liberali, Valentino; Lisovyi, Mykhailo; Liu, Lulu; Love, Jeremy; Luciano, Pierluigi; Luongo, Carmela; Magalotti, Daniel; Maznas, Ioannis; Meroni, Chiara; Mitani, Takashi; Nasimi, Hikmat; Negri, Andrea; Neroutsos, Panos; Neubauer, Mark; Nikolaidis, Spiridon; Okumura, Y; Pandini, Carlo; Petridou, Chariclia; Piendibene, Marco; Proudfoot, James; Rados, Petar Kevin; Roda, Chiara; Rossi, Enrico; Sakurai, Yuki; Sampsonidis, Dimitrios; Saxon, James; Schmitt, Stefan; Schoening, Andre; Shochet, Mel; Shoijaii, Jafar; Soltveit, Hans Kristian; Sotiropoulou, Calliope-Louisa; Stabile, Alberto; Swiatlowski, Maximilian J; Tang, Fukun; Taylor, Pierre Thor Elliot; Testa, Marianna; Tompkins, Lauren; Vercesi, V; Wang, Rui; Watari, Ryutaro; Zhang, Jianhong; Zeng, Jian Cong; Zou, Rui; Bertolucci, Federico

    2015-01-01

    The extended use of tracking information at the trigger level in the LHC is crucial for the trigger and data acquisition (TDAQ) system to fulfill its task. Precise and fast tracking is important to identify specific decay products of the Higgs boson or new phenomena, as well as to distinguish the contributions coming from the many collisions that occur at every bunch crossing. However, track reconstruction is among the most demanding tasks performed by the TDAQ computing farm; in fact, complete reconstruction at full Level-1 trigger accept rate (100 kHz) is not possible. In order to overcome this limitation, the ATLAS experiment is planning the installation of a dedicated processor, the Fast Tracker (FTK), which is aimed at achieving this goal. The FTK is a pipeline of high performance electronics, based on custom and commercial devices, which is expected to reconstruct, with high resolution, the trajectories of charged-particle tracks with a transverse momentum above 1 GeV, using the ATLAS inner tracker info...

  6. L1Track: A fast Level 1 track trigger for the ATLAS high luminosity upgrade

    International Nuclear Information System (INIS)

    Cerri, Alessandro

    2016-01-01

    With the planned high-luminosity upgrade of the LHC (HL-LHC), the ATLAS detector will see its collision rate increase by approximately a factor of 5 with respect to the current LHC operation. The earliest hardware-based ATLAS trigger stage (“Level 1”) will have to provide a higher rejection factor in a more difficult environment: a new improved Level 1 trigger architecture is under study, which includes the possibility of extracting with low latency and high accuracy tracking information in time for the decision taking process. In this context, the feasibility of potential approaches aimed at providing low-latency high-quality tracking at Level 1 is discussed. - Highlights: • HL-LH requires highly performing event selection. • ATLAS is studying the implementation of tracking at the very first trigger level. • Low latency and high-quality seem to be achievable with dedicated hardware and adequate detector readout architecture.

  7. A fast processor for di-lepton triggers

    CERN Document Server

    Kostarakis, P; Barsotti, E; Conetti, S; Cox, B; Enagonio, J; Haldeman, M; Haynes, W; Katsanevas, S; Kerns, C; Lebrun, P; Smith, H; Soszyniski, T; Stoffel, J; Treptow, K; Turkot, F; Wagner, R

    1981-01-01

    As a new application of the Fermilab ECL-CAMAC logic modules a fast trigger processor was developed for Fermilab experiment E-537, aiming to measure the higher mass di-muon production by antiprotons. The processor matches the hit information received from drift chambers and scintillation counters, to find candidate muon tracks and determine their directions and momenta. The tracks are then paired to compute an invariant mass: when the computed mass falls within the desired range, the event is accepted. The process is accomplished in times of 5 to 10 microseconds, while achieving a trigger rate reduction of up to a factor of ten. (5 refs).

  8. Organizing and implementing a multidisciplinary fast track oncology clinic.

    Science.gov (United States)

    Basta, Y L; Tytgat, K M A J; Greuter, H H; Klinkenbijl, J H G; Fockens, P; Strikwerda, J

    2017-11-01

    Patients with gastrointestinal malignancies often need multiple appointments with different medical specialists, causing waiting times to accrue. In our hospital, care is organized in a sequential manner, causing long waiting times. To reduce this, a fast track outpatient clinic (FTC) was implemented. The FTC was organized within the hospital's existing structure. Patient centered care was achieved by ensuring that the medical specialists visit the patient, implementing nurse coordinators and considering patient wishes and co-morbidities when formulating a treatment plan. A mandate from the board (Top-down), ensured cooperation between different medical departments and a change in resource allocation (i.e. medical staff); a horizontal clinic across a vertical departmental structure. Brainstorm sessions between the departments led by two physicians who were going to work at the FTC (Bottom-up), assured a swift implementation of the FTC. Since implementation in 2009, patient influx has tripled. Waiting time for an appointment and start of treatment was reduced from 2-4 weeks to 6 working days and from 12-14 weeks to 17 working days, respectively. This was achieved by re-allocating recourses, but without increasing existing resources. The combination of a top-down and bottom-up strategy ensured participation from all involved departments, a strong foundation and a shared vision on patient centered care. The FTC facilitates sharing information between different medical specialists through both proximity and a shared electronic patient record. The implementation of the FTC comprises a change in organization, but not a change in structure. © The Author 2017. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  9. Fast symplectic map tracking for the CERN Large Hadron Collider

    Directory of Open Access Journals (Sweden)

    Dan T. Abell

    2003-06-01

    Full Text Available Tracking simulations remain the essential tool for evaluating how multipolar imperfections in ring magnets restrict the domain of stable phase-space motion. In the Large Hadron Collider (LHC at CERN, particles circulate at the injection energy, when multipole errors are most significant, for more than 10^{7} turns, but systematic tracking studies are limited to a small fraction of this total time—even on modern computers. A considerable speedup is expected by replacing element-by-element tracking with the use of a symplectified one-turn map. We have applied this method to the realistic LHC lattice, version 6, and report here our results for various map orders, with special emphasis on precision and speed.

  10. History of fast reactor development in U.S.A.-I

    International Nuclear Information System (INIS)

    Ninokata, Hisashi; Sasao, Nobuyki

    2007-01-01

    History and present state of fast reactor was reviewed in series. As a history of fast reactor development in U.S.A. - I, this third lecture presented the dawn of the fast reactor development in the USA. The first fast reactor was the Clementine reactor with plutonium fuels and mercury coolant. The LAMPRE-1 reactor was the first sodium cooled and molten plutonium reactor. Experimental breeder reactor (EBR-1) was the first reactor to produce electricity and four kinds of fuels were loaded. Zero-power reactors were constructed to conduct reactor physics experiments on fast reactors. Today there are renewed interests in fast reactors due to their ability to fission actinides and reduce radioactive wastes. (T. Tanaka)

  11. Fast reactor development strategy targets study in China

    International Nuclear Information System (INIS)

    Xu Mi

    2008-01-01

    China is a big developing Country who needs a huge energy resources and a rapid growing rate. Considering energy resources limited and environment issues it is sure that the nuclear energy will be becoming one of the main energy resources. The Government has decided to develop the nuclear power capacity to 40 GW in 2020. It is envisaged that it will reach to 240 GW in 2050. It is stimulate us to consider conscientiously the development of the fast breeder reactor's and related closed nuclear fuel cycle by the limitation of Uranium resources and uncertainties of international Uranium market. Followings are the proposed strategic targets of fast reactor development in China. (1) To realize the operation of commercial fast breeder reactors with an unit size of 800-900 MWe and one site-multi reactors in 2030. (2) To develop the nuclear power capacity to 240 GW in 2050. (3) To replace step by step the fossil fuel utilization in large scale by nuclear energy beyond 2050. (authors)

  12. Dilute scintillators for large-volume tracking detectors

    Energy Technology Data Exchange (ETDEWEB)

    Reeder, R.A. (University of New Mexico, Albuquerque, NM (United States)); Dieterle, B.D. (University of New Mexico, Albuquerque, NM (United States)); Gregory, C. (University of New Mexico, Albuquerque, NM (United States)); Schaefer, F. (University of New Mexico, Albuquerque, NM (United States)); Schum, K. (University of New Mexico, Albuquerque, NM (United States)); Strossman, W. (University of California, Riverside, CA (United States)); Smith, D. (Embry-Riddle Aeronautical Univ., Prescott, AZ (United States)); Christofek, L. (Los Alamos National Lab., NM (United States)); Johnston, K. (Los Alamos National Lab., NM (United States)); Louis, W.C. (Los Alamos National Lab., NM (United States)); Schillaci, M. (Los Alamos National Lab., NM (United States)); Volta, M. (Los Alamos National Lab., NM (United States)); White, D.H. (Los Alamos National Lab., NM (United States)); Whitehouse, D. (Los Alamos National Lab., NM (United States)); Albert, M. (University of Pennsylvania, Phi

    1993-10-01

    Dilute scintillation mixtures emit isotropic light for both fast and slow particles, but retain the Cherenkov light cone from fast particles. Large volume detectors using photomultipliers to reconstruct relativistic tracks will also be sensitive to slow particles if they are filled with these mixtures. Our data show that 0.03 g/l of b-PBD in mineral oil has a 2.4:1 ratio (in the first 12 ns) of isotropic light to Cherenkov light for positron tracks. The light attenuation length is greater than 15 m for wavelength above 400 nm, and the scintillation decay time is about 2 ns for the fast component. There is also a slow isotropic light component that is larger (relative to the fast component) for protons than for electrons. This effect allows particle identification by a technique similar to pulse shape discrimination. These features will be utilized in LSND, a neutrino detector at LAMPF. (orig.)

  13. The Fast Tracker Real Time Processor: high quality real-time tracking at ATLAS

    CERN Document Server

    Stabile, A; The ATLAS collaboration

    2011-01-01

    As the LHC luminosity is ramped up to the design level of 1x1034 cm−2 s−1 and beyond, the high rates, multiplicities, and energies of particles seen by the detectors will pose a unique challenge. Only a tiny fraction of the produced collisions can be stored on tape and immense real-time data reduction is needed. An effective trigger system must maintain high trigger efficiencies for the most important physics and at the same time suppress the enormous QCD backgrounds. This requires massive computing power to minimize the online execution time of complex algorithms. A multi-level trigger is an effective solution for an otherwise impossible problem. The Fast Tracker (FTK)[1], [2] is a proposed upgrade to the current ATLAS trigger system that will operate at full Level-1 output rates and provide high quality tracks reconstructed over the entire detector by the start of processing in Level-2. FTK is a dedicated Super Computer based on a mixture of advanced technologies. The architecture broadly employs powerf...

  14. Development of a Hough transformation track finder for time projection chambers

    International Nuclear Information System (INIS)

    Heinze, Isa

    2013-12-01

    The International Linear Collider (ILC) is a planned particle physics experiment. One of the two detector concepts is the International Large Detector (ILD) concept for which a time projection chamber is foreseen as the main tracking device. In the ILD the particle flow concept is followed which leads to special requirements for the detector. Especially for the tracking system a very good momentum resolution is required. Several prototypes were build to prove that it is possible to build a TPC which fulfills the requirements for a TPC in the ILD. One is the Large Prototype with which different readout technologies currently under development are tested. In parallel reconstruction software is developed for the reconstruction of Large Prototype data. In this thesis the development of a track finding algorithm based on the Hough transformation is described. It can find curved tracks (with magnetic field) as well as straight tracks (without magnetic field). This package was mainly developed for Large Prototype testbeam data but was also tested on Monte Carlo simulation of tracks in the ILD TPC. Furthermore the analysis of testbeam data regarding the single point resolution is presented. The data were taken with the Large Prototype and a readout module with GEM (gas electron multiplier) amplification. For the reconstruction of these data the software package mentioned above was used. The single point resolution is directly related to the momentum resolution of the detector, thus a good single point resolution is needed to achieve a good momentum resolution.

  15. Development of a Hough transformation track finder for time projection chambers

    Energy Technology Data Exchange (ETDEWEB)

    Heinze, Isa

    2013-12-15

    The International Linear Collider (ILC) is a planned particle physics experiment. One of the two detector concepts is the International Large Detector (ILD) concept for which a time projection chamber is foreseen as the main tracking device. In the ILD the particle flow concept is followed which leads to special requirements for the detector. Especially for the tracking system a very good momentum resolution is required. Several prototypes were build to prove that it is possible to build a TPC which fulfills the requirements for a TPC in the ILD. One is the Large Prototype with which different readout technologies currently under development are tested. In parallel reconstruction software is developed for the reconstruction of Large Prototype data. In this thesis the development of a track finding algorithm based on the Hough transformation is described. It can find curved tracks (with magnetic field) as well as straight tracks (without magnetic field). This package was mainly developed for Large Prototype testbeam data but was also tested on Monte Carlo simulation of tracks in the ILD TPC. Furthermore the analysis of testbeam data regarding the single point resolution is presented. The data were taken with the Large Prototype and a readout module with GEM (gas electron multiplier) amplification. For the reconstruction of these data the software package mentioned above was used. The single point resolution is directly related to the momentum resolution of the detector, thus a good single point resolution is needed to achieve a good momentum resolution.

  16. The impact of a fast track area on quality and effectiveness outcomes: a Middle Eastern emergency department perspective.

    LENUS (Irish Health Repository)

    Devkaran, Subashnie

    2009-01-01

    BACKGROUND: Emergency department (ED) overcrowding is a ubiquitous problem with serious public health implications. The fast track area is a novel method which aims to reduce waiting time, patient dissatisfaction and morbidity. |The study objective was to determine the impact of a fast track area (FTA) on both effectiveness measures (i.e. waiting times [WT] and length of stay [LOS]) and quality measures (i.e. LWBS rates and mortality rates) in non-urgent patients. The secondary objective was to assess if a FTA negatively impacted on urgent patients entering the ED. METHODS: The study took place in a 500 bed, urban, tertiary care hospital in Abu Dhabi, United Arab Emirates. This was a quasi-experimental, which examined the impact of a FTA on a pre-intervention control group (January 2005) (n = 4,779) versus a post-intervention study group (January 2006) (n = 5,706). RESULTS: Mean WTs of Canadian Triage Acuity Scale (CTAS) 4 patients decreased by 22 min (95% CI 21 min to 24 min, P < 0.001). Similarly, mean WTs of CTAS 5 patients decreased by 28 min (95% CI 19 min to 37 min, P < 0.001) post FTA. The mean WTs of urgent patients (CTAS 2\\/3) were also significantly reduced after the FTA was opened (P < 0.001). The LWBS rate was reduced from 4.7% to 0.7% (95% CI 3.37 to 4.64; P < 0.001). Opening a FTA had no significant impact on mortality rates (P = 0.88). CONCLUSION: The FTA improved ED effectiveness (WTs and LOS) and quality measures (LWBS rates) whereas mortality rate remained unchanged.

  17. Development, Fabrication and Characterization of Fuels for Indian Fast Reactor Programme

    International Nuclear Information System (INIS)

    Kumar, Arun

    2013-01-01

    Development of Fast Reactor fuels in India started in early Seventies. The successful development of Mixed Carbide fuels for FBTR and MOX fuel for PFBR have given confidence in manufacture of fuels for Fast Reactors. Effort is being put to develop high Breeding Ratio Metallic fuel (binary/ternary). Few fuel pins have been fabricated and is under test irradiation. However, this is only a beginning and complete fuel cycle activities are under development. Metal fuelled Fast Reactors will provide high growth rate in Indian Fast Reactor programme

  18. Fast reactors and problems in their development. Chapter 6

    International Nuclear Information System (INIS)

    Dombey, N.

    1980-01-01

    The main differences between fast reactors, in particular the liquid-metal fast breeder reactor (LMFBR), and thermal reactors are discussed. The view is taken, based on the intrinsic physics of the systems, that fast reactors should be considered as a different genus from thermal reactors. Some conclusions are drawn for fast reactor development generally and for the British programme in particular. Physics, economics and safety aspects are covered. (U.K.)

  19. The development of fast simulation program for marine reactor parameters

    International Nuclear Information System (INIS)

    Chen Zhiyun; Hao Jianli; Chen Wenzhen

    2012-01-01

    Highlights: ► The simplified physical and mathematical models are proposed for a marine reactor system. ► A program is developed with Simulink module and Matlab file. ► The program developed has the merit of easy input preparation, output processing and fast running. ► The program can be used for the fast simulation of marine reactor parameters on the operating field. - Abstract: The fast simulation program for marine reactor parameters is developed based on the Simulink simulating software according to the characteristics of marine reactor with requirement of maneuverability and acute and fast response. The simplified core physical and thermal model, pressurizer model, steam generator model, control rod model, reactivity model and the corresponding Simulink modules are established. The whole program is developed by coupling all the Simulink modules. Two typical transient processes of marine reactor with fast load increase at low power level and load rejection at high power level are adopted to verify the program. The results are compared with those of Relap5/Mod3.2 with good consistency, and the program runs very fast. It is shown that the program is correct and suitable for the fast and accurate simulation of marine reactor parameters on the operating field, which is significant to the marine reactor safe operation.

  20. Overview of the ATLAS Fast Tracker Project

    CERN Document Server

    Ancu, Lucian Stefan; The ATLAS collaboration

    2016-01-01

    The next LHC runs, with a significant increase in instantaneous luminosity, will provide a big challenge for the trigger and data acquisition systems of all the experiments. An intensive use of the tracking information at the trigger level will be important to keep high efficiency for interesting events despite the increase in multiple collisions per bunch crossing. In order to increase the use of tracks within the High Level Trigger, the ATLAS experiment planned the installation of a hardware processor dedicated to tracking: the Fast TracKer processor. The Fast Tracker is designed to perform full scan track reconstruction of every event accepted by the ATLAS first level hardware trigger. To achieve this goal the system uses a parallel architecture, with algorithms designed to exploit the computing power of custom Associative Memory chips, and modern field programmable gate arrays. The processor will provide computing power to reconstruct tracks with transverse momentum greater than 1 GeV in the whol...

  1. Materials development for fast reactor applications

    Energy Technology Data Exchange (ETDEWEB)

    Jayakumar, T.; Mathew, M.D.; Laha, K.; Sandhya, R., E-mail: san@igcar.gov.in

    2013-12-15

    Highlights: • A modified version of alloy D9 designated as IFAC-1 has been developed. • Oxide dispersion strengthened Grade 91 steel with good creep strength developed. • 0.14 wt% nitrogen in 316LN stainless steel leads to improved mechanical properties. • Type IV cracking resistant Grade 91 steel with boron addition developed. • Mechanical properties of SFR materials evaluated in sodium environment. -- Abstract: Materials play a crucial role in the economic competitiveness of electricity produced from fast reactors. It is necessary to increase the fuel burn-up and design life in order to realize this objective. The burnup is largely limited by the void swelling and creep resistance of the fuel cladding and wrapping materials. India's 500 MWe Prototype Fast Breeder Reactor (PFBR) is in advanced stage of construction. The major structural materials chosen for PFBR with MOX fuel are D9 austenitic stainless steel as fuel clad and wrapper material, 316LN austenitic stainless steel for reactor components and piping and modified 9Cr-1Mo steel for steam generator. In order to improve the burnup, titanium, phosphorous and silicon contents in alloy D9 have been optimized for decreased void swelling and increased creep strength and this has led to the development of a modified version of alloy D9 as IFAC-1. Ferritic steels are inherently resistant to void swelling. The disadvantage is their poor creep strength. Creep resistance of 9Cr-ferritic steel has been improved with the dispersion of nano-size yttria to develop oxide dispersion strengthened (ODS) steel clad tube with long-term creep strength, comparable to alloy D9 so as to achieve higher fuel burnup. Improved versions of 316LN stainless steel with nitrogen content of about 0.14 wt% having higher creep strength to increase the life of fast reactors and modified 9Cr-1Mo steel with reduced nitrogen content and controlled addition of boron to improve type IV cracking resistance for steam generator

  2. China's challenging fast track. Far more energy will have to be produced - and conserved - to power the expanding economy and protect the environment

    International Nuclear Information System (INIS)

    Wei Zhihong

    2004-01-01

    China's economy is on a fast track, with growth projected to quadruple in the first two decades of this century. A mix of clean and affordable energy sources will be needed to fuel and sustain development. Since China opened to outside markets in the 1980s, the national economy has expanded steadily, with an average annual growth rate of 9.6% in gross domestic product (GDP) from 1980 to 2000. Development has stayed strong in this century, and GDP grew 9.1% in 2003, the highest rate in the past six years. For the first time, per capita GDP topped $1000, reaching $1090 last year. How to best manage and sustain growth is driving energy decisions. Analyses show that China has entered a stage of manufacturing, chemical, and heavy industrial development that is energy intensive. At the same time, demands for energy at home and in businesses are growing among China's population of 1.3 billion people. As consumption grows, so do concerns about air, water, and land pollution in the context of sustainable energy development

  3. Development of a tracking method for augmented reality applied to NPP maintenance work and its experimental evaluation

    International Nuclear Information System (INIS)

    Bian, Zhiqiang; Ishii, Hirotake; Shimoda, Hiroshi; Yoshikawa, Hidekazu; Morishita, Yoshitsugu; Kanehira, Yoshiki; Izumi, Masanori

    2007-01-01

    Nuclear power plants (NPPs) must be maintained periodically. Their maintenance efficiency must be improved and human error must be reduced simultaneously to improve NPPs' competitive capability in electricity markets. Although Augmented Reality (AR) offers great possibilities to support NPP maintenance work, some difficulties exist for application of AR to actual work support because current AR systems cannot be implemented in NPP environments without technical improvement. There are several kinds of problems such as recognition distance, tracking accuracy, and a complex working environment when applying AR to NPP field work support. Considerable extension of tracking distance and improvement of accuracy are particularly desired because NPPs are large scale indoor environments. This study designed a linecode marker, a new type of paper-based marker, along with recognition and tracking algorithms for it to resolve these problems. In contrast to conventional paper-based makers, such as square markers and circle markers, the linecode marker is not merely easier to set up in complex industrial environments: it also enables the use of AR in industrial plants because of its considerable tracking-performance improvement. To evaluate tracking accuracy, the trackable distance, and the tracking speed of the proposed tracking method, an evaluation experiment was conducted in a large room. The experiment results show that the tracking distance is extended extremely over that of the traditional marker-based tracking method: tracking accuracy improved to 20 cm over a 10 m distance. The running speed of the tracking can be as fast as 15 frames per second using a laptop PC. (author)

  4. ESC Track Fusion Demonstration Tool for Distributed Environments

    Science.gov (United States)

    Cox, C.; Degraaf, E.; Perry, R.; Diaz, R.

    A key requirement of future net-centric Space Situational Awareness systems development and operations will be decentralized operations, including multi-level distributed data fusion. Raytheon has developed a demonstration for ESC 850 ELSG/NS that fuses sensor-supplied tracks in a dense resident space object (RSO) environment. The demonstration use the state vector and covariance input data from single pass orbit solutions and applies track-to-track correlation algorithms to fuse the individual tracks into composite orbits. Platform independent Java technology and an agent-based software design using asynchronous inter-process communications was used in the demonstration tool development. The tool has been tested against a simulated scenario corresponding to the future 100,000+ object catalog environment. Ten days of simulated data from Fylingdales, Shemya, Eglin, and a future Space Fence sensor were generated for a co-orbiting family of 122 sun-synchronous objects between 700 and 800 km altitude from the NASA simulated small debris for 2015. The selected set exceeds the average object densities for the 100,000+ RSO environment, and provides a scenario similar to an evolved breakup where the debris has had time to disperse. The demo produced very good results using fast and simple astrodynamic models. A total of 16678 input tracks were fused, with less than 1.6% being misassociated. Pure tracks were generated for 65% of the 122 truth objects, and 97% of the objects had a misassociation rate tool that can be used to assess current breakups such as the Chinese ASAT event.

  5. An energy and direction independent fast neutron dosemeter based on electrochemically etched CR-39 nuclear track detectors

    International Nuclear Information System (INIS)

    James, K.; Matiullah; Durrani, S.A.

    1987-01-01

    A computer-based model is presented, which simulates the dose equivalent response of electrochemically etched CR-39 to fast neutrons of various energies and angles of incidence. Most previous calculations of the response of CR-39 have neglected the production of recoiling oxygen and carbon nuclei as well as α particles in the CR-39. We calculate that these 'heavy recoils' and α particles are the major source of electrochemically etchable tracks in bare CR-39 at neutron energies above approx. 2 MeV under typical etching conditions. Our calculations have been extended to predict the response of CR-39 used in conjunction with various combinations of polymeric front radiators and we have determined the radiator stack configuration with produces the most energy independent response. Again, the heavy recoils and α particles cannot be neglected and, for energies above approx. 2 MeV, these produce typically about 20% of the total response of our optimum stack. This type of fast neutron dosemeter is, however, strongly direction dependent. We have integrated the response over all appropriate angles to predict the dose equivalent response for two representative neutron fields, and we suggest a method for minimising the angular dependence. (author)

  6. Tracking health-related Sustainable Development Goals (SDGs in Nepal

    Directory of Open Access Journals (Sweden)

    Meghnath Dhimal

    2017-07-01

    Full Text Available Sustainable Development Goals (SDGs comprise of 17 goals and 169 targets. All SDGs are interlinked to produce synergetic eff ects and emphasize health in all policies. Among the 17 Goals, Goal 3 has a central focus on health, which is underpinned by 13 targets. The other 16 goals are also directly or indirectly related to health and will contribute to achieving the associated targets for Goal 3. The ambitious SDG agenda and their progress can be tracked by measuring numerous goals, targets, and indicators. The main objective of this paper is to provide an overview about how health- related SDGs and their targets and indicators are being tracked in the national context of Nepal. Adequate investment in research for knowledge generation, capacity building and innovation, and continous research communication among policy makers, researchers and external development partners will contribute to tracking the progress of SDGs in Nepal.

  7. In vivo cell tracking with bioluminescence imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Eun; Kalimuthu, Senthilkumar; Ahn, Byeong Cheol [Dept. of Nuclear Medicine, Kyungpook National University School of Medicine and Hospital, Daegu (Korea, Republic of)

    2015-03-15

    Molecular imaging is a fast growing biomedical research that allows the visual representation, characterization and quantification of biological processes at the cellular and subcellular levels within intact living organisms. In vivo tracking of cells is an indispensable technology for development and optimization of cell therapy for replacement or renewal of damaged or diseased tissue using transplanted cells, often autologous cells. With outstanding advantages of bioluminescence imaging, the imaging approach is most commonly applied for in vivo monitoring of transplanted stem cells or immune cells in order to assess viability of administered cells with therapeutic efficacy in preclinical small animal models. In this review, a general overview of bioluminescence is provided and recent updates of in vivo cell tracking using the bioluminescence signal are discussed.

  8. Nuclear Track-Etched Pore Membrane Production Using OAEP's Research Reactor

    International Nuclear Information System (INIS)

    Chittrakarn, Thawat; Bhongsuwan, Tripob; Wanichapichart, Pikul; Nuanuin, Paiboon; Chongkum, Somporn; Khonduangkaew, Areerat; Bordeepong, Sunaree

    2003-10-01

    Result of this study shows that the OAEP's nuclear research reactor is a good source of both fast and thermal neutrons for pore piercing process on polycarbonate thin film. With our experimental design, the fast neutron provides better results in pore piercing comparing with thermal neutron bombardment. This can be explained that most of the latent tracks that occur by thermal neutron bombardment do not piercing through the thin film. Chemical etching process using NaOH solution with an appropriated time, concentration and temperature was employed to enlarge the latent tracks in the bombarded film by fast neutrons. Fast neutron bombardment with 5, 10 and 20 minutes bombarding time successfully produces the nuclear track membrane. Pore size and pore density of the produced membranes examined by SEM were 0.24-1.01 μm and 4.67 - 245 x 10 6 pore/cm 2 , respectively. Bubble point test showed the maximum pore diameter of the produced membrane ranged between 1.18 - 3.25 μm. Water permeability was studied and compared between the produced and commercial membranes

  9. Fast tracking detector with fiber scintillators and a position sensitive photomultiplier

    International Nuclear Information System (INIS)

    Salomon, M.; Li, V.; Smith, G.; Wu, Y.S.

    1988-11-01

    We have studied the properties of a tracking detector composed of 32 fiber scintillators coupled to a multianode photomultiplier placed in a pion beam at TRIUMF. We measured the efficiency of the detector, as well as its tracking capabilities and double hit resolution

  10. Diagnostic methods for fast-track identification of endometrial cancer in women with postmenopausal bleeding and endometrial thickness greater than 5 mm

    DEFF Research Database (Denmark)

    Dueholm, Margit; Marinowskij, Edvard; Hansen, Estrid Stæhr

    2015-01-01

    efficiency (area under the curve) for malignancy diagnosis (ES, 0.90; TVS, 0.88; GIS, 0.92; HYpattern, 0.91). When insufficient samples were incorporated, ES was less efficient than the other techniques. ES was not more efficient in the subgroup of women without localized lesions than in the subgroup...... of women with localized lesions. MRI and HYpattern added limited efficiency, whereas hysteroscopy with biopsy was most efficient. CONCLUSIONS: As a first-line technique, pattern recognition on TVS, GIS, and HYpattern correctly identifies 9 of 10 women with malignancy and is superior to pattern recognition...... on ES when insufficient samples are included. Endometrial pattern evaluated with TVS and GIS is a fast and efficient first-line diagnostic tool that outperforms ES in women with or without localized lesions. Malignant patterns on TVS/GIS should warrant fast-track evaluation, whereas women with benign...

  11. Multiphase Interface Tracking with Fast Semi-Lagrangian Contouring.

    Science.gov (United States)

    Li, Xiaosheng; He, Xiaowei; Liu, Xuehui; Zhang, Jian J; Liu, Baoquan; Wu, Enhua

    2016-08-01

    We propose a semi-Lagrangian method for multiphase interface tracking. In contrast to previous methods, our method maintains an explicit polygonal mesh, which is reconstructed from an unsigned distance function and an indicator function, to track the interface of arbitrary number of phases. The surface mesh is reconstructed at each step using an efficient multiphase polygonization procedure with precomputed stencils while the distance and indicator function are updated with an accurate semi-Lagrangian path tracing from the meshes of the last step. Furthermore, we provide an adaptive data structure, multiphase distance tree, to accelerate the updating of both the distance function and the indicator function. In addition, the adaptive structure also enables us to contour the distance tree accurately with simple bisection techniques. The major advantage of our method is that it can easily handle topological changes without ambiguities and preserve both the sharp features and the volume well. We will evaluate its efficiency, accuracy and robustness in the results part with several examples.

  12. The EDRO board connected to the Associative Memory: a "Baby" FastTracKer processor for the ATLAS experiment

    CERN Document Server

    Annovi, A; Bevacqua, V; Cervigni, F; Crescioli, F; Fabbri, L; Giannetti, P; Giorgi, F; Magalotti, D; Negri, A; Piendibene, M; Roda, C; Sbarra, C; Villa, M; Vitillo, RA; Volpi, G

    2012-01-01

    The FastTracKer (FTK), a hardware dedicated processor, performs fast and precise online full track reconstruction at the ATLAS experiment, within an average latency of few dozens of microseconds. \\ It is made of two pipelined processors, the Associative Memory finding low precision tracks, and the Track Fitter refining the track quality with high precision fits. FTK has to face the Large Hadron Collider (LHC) Phase I luminosity. So, while the new processor requires the best of the available technology for tracking in high occupancy conditions, we want to use already existing prototypes to exercise soon the FTK functions in the new ATLAS environment. Few boards connected together constitute a "baby FTK" that will grow soon becoming the "vertical slice".\\ The vertical slice will cover a small projective wedge in the detector, but it will be functionally complete. It will provide a full test of the entire FTK data chain, in the laboratory first and on beam-on conditions after. It will require early development a...

  13. The EDRO board connected to the Associative Memory: a "Baby" FastTracKer processor for the ATLAS experiment

    CERN Document Server

    Annovi, A; The ATLAS collaboration; Villa, M; Bevacqua, V; Vitillo, R A; Giorgi, F; Magalotti, D; Roda, C; Cervigni, F; Giannetti, P; Negri, A; Piendibene, M; Volpi, G; Fabbri, L; Sbarra, C

    2011-01-01

    The FastTracKer (FTK) is a dedicated hardware system able to perform online fast and precise track reconstruction of the full events at the Atlas experiment, within an average latency of few dozens of microseconds. It is made of two pipelined processors: the Associative Memory (AM), finding low precision tracks called "roads", and the Track Fitter (TF), refining the track quality with high precision fits. The FTK design [1] that works well at the Large Hadron Collider (LHC) Phase I luminosity requires the best of the available technology for tracking in high occupancy conditions. While the new processor is designed for the most demanding LHC conditions, we want to use already existing prototypes, part of them developed for the SLIM5 collaboration [2], to exercise the FTK functions in the new Atlas environment. During Laboratory tests, the EDRO board (Event Dispatch and Read-Out) receives on a clustering mezzanine (able to calculate the pixel and SCT cluster centroids) "fake" detector raw data on S-links from ...

  14. Development of Optical Fiber Detector for Measurement of Fast Neutron

    International Nuclear Information System (INIS)

    YAGI, Takahiro; KAWAGUCHI, Shinichi; MISAWA, Tsuyoshi; PYEON, Cheol Ho; UNESAKI, Hironobu; SHIROYA, Seiji; OKAJIMA, Shigeaki; TANI, Kazuhiro

    2008-01-01

    Measurement of fast neutron flux is important for investigation of characteristic of fast reactors. In order to insert a neutron detector in a narrow space such as a gap of between fuel plates and measure the fast neutrons in real time, a neutron detector with an optical fiber has been developed. This detector consists of an optical fiber whose tip is covered with mixture of neutron converter material and scintillator such as ZnS(Ag). The detector for fast neutrons uses ThO 2 as converter material because 232 Th makes fission reaction with fast neutrons. The place where 232 Th can be used is limited by regulations because 232 Th is nuclear fuel material. The purpose of this research is to develop a new optical fiber detector to measure fast neutrons without 232 Th and to investigate the characteristic of the detector. These detectors were used to measure a D-T neutron generator and fast neutron flux distribution at Fast Critical Assembly. The results showed that the fast neutron flux distribution of the new optical fiber detector with ZnS(Ag) was the same as it of the activation method, and the detector are effective for measurement of fast neutrons. (authors)

  15. Energy dependence of fast neutron dosimetry using electrochemical etching

    International Nuclear Information System (INIS)

    Su, S.J.; Morgan, K.Z.

    1978-01-01

    Registration of fast-neutron induced recoil tracks by the electrochemical etching technique as applied to sensitive Lexan polycarbonate foils provides a simple and inexpensive means of fast neutron personnel dosimetry. The sensitivity (tracks/neutron) of recoil particle registration is given as a function of neutron energy. Neutrons of 7 Li (p,n) 7 Be, 3 T (d,n) 4 He and 9 B, respectively. Results are compared with other studies using other neutron sources and conventional etching method

  16. Fast Fiber-Coupled Imaging Devices

    Energy Technology Data Exchange (ETDEWEB)

    Brockington, Samuel; Case, Andrew; Witherspoon, Franklin

    2018-04-22

    metal pillars in the path of the plasma jets were recorded in a single shot. This new fast imaging system is an attractive alternative to conventional fast framing cameras for applications and experiments where imaging events using existing techniques are inefficient or impossible. The development of HyperV's new diagnostic was split into two tracks: a next generation camera track, in which HyperV built, tested, and demonstrated a prototype 1024 channel camera at its own facility, and a second plasma community beta test track, where selected plasma physics programs received small systems of a few test pixels to evaluate the expected performance of a full scale camera on their experiments. These evaluations were performed as part of an unfunded collaboration with researchers at Los Alamos National Laboratory and the University of California at Davis. Results from the prototype 1024-pixel camera are discussed, as well as results from the collaborations with test pixel system deployment sites.

  17. Development of the dyed-track method for Kodak CN-85 detector

    International Nuclear Information System (INIS)

    Somogyi, G.; Toth-Szilagyi, M.; Varga, Z.; Monnin, M.; Lferde, M.

    1984-01-01

    The dyed-track method has been successfully developed for cellulose derivatives. The track parameters (width, colouration deepness, contrast, registration sensitivity), however, proved to be very dependent on the detector material and on the track processing conditions. In our previous works optimum conditions were presented mostly for cellulose acetate sheets. In the present work we have studied the influence of track processing parameters on the dyed-track formation in Kodak cellulose nitrate detector called CN-85. It is found that in this material optimum dyed-tracks can be produced with using no swelling but with a thermal annealing at 100 deg C for 1 hour after particle irradiation. For sensitization a treatment with 15% HCl at 22 deg C for 20 hours and for dyeing 0.3 wt% Rhodamine-B at 100 deg C for 1 hour proved to be the best. For better understanding the track dyeing phenomenon we have studied the colouration behaviour of electron-irradiated CN-85 detectors. (author)

  18. Development of the dyed-track method for Kodak CN-85 detector

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, G.; Toth-Szilagyi, M.; Varga, Z. (Magyar Tudomanyos Akademia, Debrecen. Atommag Kutato Intezete); Monnin, M.; Lferde, M. (Clermont-Ferrand-2 Univ., 63 - Aubiere (France). Lab. de Physique Corpusculaire)

    1984-01-01

    The dyed-track method has been successfully developed for cellulose derivatives. The track parameters (width, colouration deepness, contrast, registration sensitivity), however, proved to be very dependent on the detector material and on the track processing conditions. In our previous works optimum conditions were presented mostly for cellulose acetate sheets. In the present work we have studied the influence of track processing parameters on the dyed-track formation in Kodak cellulose nitrate detector called CN-85. It is found that in this material optimum dyed-tracks can be produced with using no swelling but with a thermal annealing at 100 deg C for 1 hour after particle irradiation. For sensitization a treatment with 15% HCl at 22 deg C for 20 hours and for dyeing 0.3 wt% Rhodamine-B at 100 deg C for 1 hour proved to be the best. For better understanding the track dyeing phenomenon we have studied the colouration behaviour of electron-irradiated CN-85 detectors.

  19. Ultra-fast silicon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sadrozinski, H. F.-W., E-mail: hartmut@scipp.ucsc.edu [Santa Cruz Institute for Particle Physics, UC Santa Cruz, Santa Cruz, CA 95064 (United States); Ely, S.; Fadeyev, V.; Galloway, Z.; Ngo, J.; Parker, C.; Petersen, B.; Seiden, A.; Zatserklyaniy, A. [Santa Cruz Institute for Particle Physics, UC Santa Cruz, Santa Cruz, CA 95064 (United States); Cartiglia, N.; Marchetto, F. [INFN Torino, Torino (Italy); Bruzzi, M.; Mori, R.; Scaringella, M.; Vinattieri, A. [University of Florence, Department of Physics and Astronomy, Sesto Fiorentino, Firenze (Italy)

    2013-12-01

    We propose to develop a fast, thin silicon sensor with gain capable to concurrently measure with high precision the space (∼10 μm) and time (∼10 ps) coordinates of a particle. This will open up new application of silicon detector systems in many fields. Our analysis of detector properties indicates that it is possible to improve the timing characteristics of silicon-based tracking sensors, which already have sufficient position resolution, to achieve four-dimensional high-precision measurements. The basic sensor characteristics and the expected performance are listed, the wide field of applications are mentioned and the required R and D topics are discussed. -- Highlights: •We are proposing thin pixel silicon sensors with 10's of picoseconds time resolution. •Fast charge collection is coupled with internal charge multiplication. •The truly 4-D sensors will revolutionize imaging and particle counting in many applications.

  20. Fast breeder fuel element development

    International Nuclear Information System (INIS)

    Marth, W.; Muehling, G.

    1983-08-01

    This report is a compilation of the papers which have been presented during a seminar ''Fast Breeder Fuel Element Development'' held on November 15/16, 1982 at KfK. The papers give a survey of the status, of the obtained results and of the necessary work, which still has to be done in the frame of various development programmes for fast breeder fuel elements. In detail the following items were covered by the presentations: - the requirements and boundary conditions for the design of fuel pins and elements both for the reference concept of the SNR 300 core and for the large, commercial breeder type of the future (presentation 1,2 and 6); - the fabrication, properties and characterization of various mixed oxide fuel types (presentations 3,4 and 5); - the operational fuel pin behaviour, limits of different design concepts and possible mechanism for fuel pin failures (presentations (7 and 8); - the situation of cladding- and wrapper materials development especially with respect to the high burn-up values of commercial reactors (presentations 9 and 10); - the results of the irradiation experiments performed under steady-state and non-stationary operational conditions and with failed fuel pins (presentations 11, 12, 13 and 14). (orig./RW) [de

  1. Fast front-end electronics for semiconductor tracking detectors: Trends and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Rivetti, Angelo

    2014-11-21

    In the past few years, extensive research efforts pursued by both the industry and the academia have lead to major improvements in the performance of Analog to Digital Converters (ADCs) and Time to Digital Converters (TDCs). ADCs achieving 8–10 bit resolution, 50–100 MHz conversion frequency and less than 1 mW power consumption are the today's standard, while TDCs have reached sub-picosecond time resolution. These results have been made possible by architectural upgrades combined with the use of ultra deep submicron CMOS technologies with minimum feature size of 130 nm or smaller. Front-end ASICs in which a prompt digitization is followed by signal conditioning in the digital domain can now be envisaged also within the tight power budget typically available in high density tracking systems. Furthermore, tracking detectors embedding high resolution timing capabilities are gaining interest. In the paper, ADC's and TDC's developments which are of particular relevance for the design front-end electronics for semiconductor trackers are discussed along with the benefits and challenges of exploiting such high performance building blocks in implementing the next generation of ASICs for high granularity particle detectors.

  2. Automated cell tracking and analysis in phase-contrast videos (iTrack4U): development of Java software based on combined mean-shift processes.

    Science.gov (United States)

    Cordelières, Fabrice P; Petit, Valérie; Kumasaka, Mayuko; Debeir, Olivier; Letort, Véronique; Gallagher, Stuart J; Larue, Lionel

    2013-01-01

    Cell migration is a key biological process with a role in both physiological and pathological conditions. Locomotion of cells during embryonic development is essential for their correct positioning in the organism; immune cells have to migrate and circulate in response to injury. Failure of cells to migrate or an inappropriate acquisition of migratory capacities can result in severe defects such as altered pigmentation, skull and limb abnormalities during development, and defective wound repair, immunosuppression or tumor dissemination. The ability to accurately analyze and quantify cell migration is important for our understanding of development, homeostasis and disease. In vitro cell tracking experiments, using primary or established cell cultures, are often used to study migration as cells can quickly and easily be genetically or chemically manipulated. Images of the cells are acquired at regular time intervals over several hours using microscopes equipped with CCD camera. The locations (x,y,t) of each cell on the recorded sequence of frames then need to be tracked. Manual computer-assisted tracking is the traditional method for analyzing the migratory behavior of cells. However, this processing is extremely tedious and time-consuming. Most existing tracking algorithms require experience in programming languages that are unfamiliar to most biologists. We therefore developed an automated cell tracking program, written in Java, which uses a mean-shift algorithm and ImageJ as a library. iTrack4U is a user-friendly software. Compared to manual tracking, it saves considerable amount of time to generate and analyze the variables characterizing cell migration, since they are automatically computed with iTrack4U. Another major interest of iTrack4U is the standardization and the lack of inter-experimenter differences. Finally, iTrack4U is adapted for phase contrast and fluorescent cells.

  3. Automated cell tracking and analysis in phase-contrast videos (iTrack4U: development of Java software based on combined mean-shift processes.

    Directory of Open Access Journals (Sweden)

    Fabrice P Cordelières

    Full Text Available Cell migration is a key biological process with a role in both physiological and pathological conditions. Locomotion of cells during embryonic development is essential for their correct positioning in the organism; immune cells have to migrate and circulate in response to injury. Failure of cells to migrate or an inappropriate acquisition of migratory capacities can result in severe defects such as altered pigmentation, skull and limb abnormalities during development, and defective wound repair, immunosuppression or tumor dissemination. The ability to accurately analyze and quantify cell migration is important for our understanding of development, homeostasis and disease. In vitro cell tracking experiments, using primary or established cell cultures, are often used to study migration as cells can quickly and easily be genetically or chemically manipulated. Images of the cells are acquired at regular time intervals over several hours using microscopes equipped with CCD camera. The locations (x,y,t of each cell on the recorded sequence of frames then need to be tracked. Manual computer-assisted tracking is the traditional method for analyzing the migratory behavior of cells. However, this processing is extremely tedious and time-consuming. Most existing tracking algorithms require experience in programming languages that are unfamiliar to most biologists. We therefore developed an automated cell tracking program, written in Java, which uses a mean-shift algorithm and ImageJ as a library. iTrack4U is a user-friendly software. Compared to manual tracking, it saves considerable amount of time to generate and analyze the variables characterizing cell migration, since they are automatically computed with iTrack4U. Another major interest of iTrack4U is the standardization and the lack of inter-experimenter differences. Finally, iTrack4U is adapted for phase contrast and fluorescent cells.

  4. Caltech computer scientists develop FAST protocol to speed up Internet

    CERN Multimedia

    2003-01-01

    "Caltech computer scientists have developed a new data transfer protocol for the Internet fast enough to download a full-length DVD movie in less than five seconds. The protocol is called FAST, standing for Fast Active queue management Scalable Transmission Control Protocol" (1 page).

  5. Analysis of the use of obfusctated web tracking

    OpenAIRE

    Fallace, Federico

    2017-01-01

    In the last years, web tracking has became a fast-growing phenomenon. Pro- filing users to provide targeted advertisement is a business that counts hundreds of companies and billions of dollars. On the other hand, communities, researchers and other companies are building countermeasures to prevent tracking practices, so the techniques are becoming more sophisticated and hidden. This work has the goal of uncovering the obfuscation that is becoming common in web tracking metho...

  6. Fast Flux Test Facility Asbestos Location Tracking Program

    International Nuclear Information System (INIS)

    REYNOLDS, J.A.

    1999-01-01

    Procedure Number HNF-PRO-408, revision 0, paragraph 1.0, ''Purpose,'' and paragraph 2.0, ''Requirements for Facility Management of Asbestos,'' relate building inspection and requirements for documentation of existing asbestos-containing building material (ACBM) per each building assessment. This documentation shall be available to all personnel (including contractor personnel) entering the facility at their request. Corrective action was required by 400 Area Integrated Annual Appraisal/Audit for Fiscal Year 1992 (IAA-92-0007) to provide this notification documentation. No formal method had been developed to communicate the location and nature of ACBM to maintenance personnel in the Fast Flux Test Facility (FFTF) 400 Area. The scope of this Data Package Document is to locate and evaluate any ACBM found at FFTF which constitutes a baseline. This includes all buildings within the protected area. These findings are compiled from earlier reports, numerous work packages and engineering evaluations of employee findings

  7. Single-photon sensitive fast ebCMOS camera system for multiple-target tracking of single fluorophores: application to nano-biophotonics

    Science.gov (United States)

    Cajgfinger, Thomas; Chabanat, Eric; Dominjon, Agnes; Doan, Quang T.; Guerin, Cyrille; Houles, Julien; Barbier, Remi

    2011-03-01

    Nano-biophotonics applications will benefit from new fluorescent microscopy methods based essentially on super-resolution techniques (beyond the diffraction limit) on large biological structures (membranes) with fast frame rate (1000 Hz). This trend tends to push the photon detectors to the single-photon counting regime and the camera acquisition system to real time dynamic multiple-target tracing. The LUSIPHER prototype presented in this paper aims to give a different approach than those of Electron Multiplied CCD (EMCCD) technology and try to answer to the stringent demands of the new nano-biophotonics imaging techniques. The electron bombarded CMOS (ebCMOS) device has the potential to respond to this challenge, thanks to the linear gain of the accelerating high voltage of the photo-cathode, to the possible ultra fast frame rate of CMOS sensors and to the single-photon sensitivity. We produced a camera system based on a 640 kPixels ebCMOS with its acquisition system. The proof of concept for single-photon based tracking for multiple single-emitters is the main result of this paper.

  8. Application of fast track surgery in elderly patients during perioperative period of laparoscopic cholecystectomy

    Directory of Open Access Journals (Sweden)

    ZHANG Yong

    2014-12-01

    Full Text Available ObjectiveTo investigate the safety and superiority of fast track surgery (FTS in elderly patients during the perioperative period of laparoscopic cholecystectomy (LC. MethodsThe clinical data of 124 elderly patients who underwent LC at the Department of General Surgery in our institution between January 2010 and March 2014 were assessed, with 62 cases assigned to FTS group and 62 cases to conventional method group. Anal exhaust time, feeding time, off-bed activity time, and length of hospital stay were compared between the two groups, and postoperative results and adverse reactions were recorded. Continuous data were analyzed using the independent-samples t test, and categorical data were compared using the chi-square test. Results Compared with the control method group, patients in the FTS group showed earlier postoperative anal exhaust, feeding, and off-bed activity, a shorter length of hospital stay, and a lower incidence of postoperative cardiovascular and cerebrovascular complications (P<0.05. ConclusionFTS is an effective approach to accelerate rehabilitation in elderly patients after LC.

  9. Silicon detectors for tracking and vertexing

    International Nuclear Information System (INIS)

    Nomerotski, Andrei

    2009-01-01

    This review covers recent developments in silicon detectors used for particle physics experiments for the tracking and vertexing systems. After a general introduction the main focus of the report is on new challenges for this field posed by requirements of the future generation machines. Technologies reviewed in more detail are column parallel CCDs, DEPFET, vertical integration of sensors and electronics and several others which allow fast readout and low mass design. Important system issues such as mechanical arrangements for the sensors and power distribution, which are critical for the low mass design, are also discussed.

  10. Status of fast reactor control rod development in the United Kingdom

    International Nuclear Information System (INIS)

    Kelly, B.T.

    1984-01-01

    The two large fast reactors constructed in the United Kingdom, that is the Dounreay Fast Reactor (DFR) and the Prototype Fast Reactor (PFR) differed substantially in their control systems. DFR was controlled by variation of the neutron leakage from the core while PFR uses conventional control rods containing neutron absorbing materials. This paper describes the development of the PFR control systems, the progressive design of the control systems for the prototype Civil Fast Reactor (CFR) and the supporting research and development programmes. (author)

  11. Development of hybrid track detector using CR39 and photographic plate

    International Nuclear Information System (INIS)

    Kuge, K.; Endo, Y.; Hayashi, K.; Iwakiri, S.; Hasegawa, A.; Yasuda, N.; Kumagai, H.

    2005-01-01

    To improve the hybrid track detector using both CR39 and silver halide photography the gold deposition development technique was applied to this. Nuclear tracks composed of gold clusters were obtained. This method has several advantages; 1. no filament formation, 2. easy control of the cluster size owing to the independence of the size of silver halide grain, 3. easy treatment of the waste solution of developer. (author)

  12. Measurement of accelerator-based neutron distributions using nuclear track detectors

    International Nuclear Information System (INIS)

    Al-Jarallah, M.I.; Abu-Jarad, F.; Rehman, Fazal-ur-; Khiari, F.Z.; Aksoy, A.; Nassar, R.

    2000-01-01

    Nuclear track detectors were used to measure the longitudinal and transverse distributions of slow neutrons in a moderated neutron field as well as the longitudinal and transverse distributions of fast neutrons produced on the 0 deg. beam line of the KFUPM 350 keV ion accelerator. The neutrons were first produced from the T(d,n) 4 He reaction with a neutron energy of approximately 14 MeV and were then moderated in a cylindrical polyethylene moderator placed at the end of the 0 deg. beam line. The optimal transverse slow neutron distribution was found to be uniform within ±4.5% at a 3 cm depth inside the moderator. The fast neutron distribution component along the moderator central axis exhibited an exponential-like drop in intensity with depth. Linearity checks of alpha and proton recoil track density with irradiation time for the nuclear track detectors were verified for both slow and fast neutrons

  13. Measurement of accelerator-based neutron distributions using nuclear track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jarallah, M.I. E-mail: mibrahim@kfupm.edu.sa; Abu-Jarad, F.; Rehman, Fazal-ur-; Khiari, F.Z.; Aksoy, A.; Nassar, R

    2000-12-01

    Nuclear track detectors were used to measure the longitudinal and transverse distributions of slow neutrons in a moderated neutron field as well as the longitudinal and transverse distributions of fast neutrons produced on the 0 deg. beam line of the KFUPM 350 keV ion accelerator. The neutrons were first produced from the T(d,n){sup 4}He reaction with a neutron energy of approximately 14 MeV and were then moderated in a cylindrical polyethylene moderator placed at the end of the 0 deg. beam line. The optimal transverse slow neutron distribution was found to be uniform within {+-}4.5% at a 3 cm depth inside the moderator. The fast neutron distribution component along the moderator central axis exhibited an exponential-like drop in intensity with depth. Linearity checks of alpha and proton recoil track density with irradiation time for the nuclear track detectors were verified for both slow and fast neutrons.

  14. Fast track in total hip and knee arthroplasty--experiences from Hvidovre University Hospital, Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte

    2006-01-01

    This study investigated whether unselected patients operated on with total hip arthroplasty (THA) or total knee arthroplasty (TKA) could accomplish a self-developed accelerated track, ANORAK-HH, with a planned length of stay (LOS) of maximum 5 days and patient satisfaction at all parts of the tra...

  15. Fast track developments, Gulf of Mexico -- options and organization

    International Nuclear Information System (INIS)

    Craig, M.J.K.; Carruth, R.E.

    1995-01-01

    The pressure continues to compress the 'idea to barrel' time period -- to get oil and gas from a discovery into the pipeline as quickly, cheaply and safely as possible. This paper discusses the range of development options presently available in the Gulf of Mexico (GoM) to meet these goals, and a project organizational structure that allows for maximum implementation efficiency. The structural options range from a standard 4-pile to a single, freestanding caisson, and the spectrum of 'minimum structures' in between. Developments in water depths of 100 feet and 200 feet are addressed, as are each system's associated costs, relative risks and startup times. Project organization is also addressed in terms of an effective in-house and out-of-house project organizational structure, the necessary attributes of the key members of this organization, and the most effective types of contracting

  16. A Fast-Track Path to DEMO Enabled by ITER and FNSF-AT

    Energy Technology Data Exchange (ETDEWEB)

    Garofalo, A. M.; Choi, M.; Humphreys, D. A.; Kinsey, J. E.; Lao, L. L.; Snyder, P. B.; John, H. E.St.; Turnbull, A. D.; Taylor, T.S., E-mail: garofalo@fusion.gat.com [General Atomics, San Diego (United States); Chan, V. S.; Canik, J. M. [Oak Ridge National Laboratory, Oak Ridge (United States); Sawan, M. E. [University of Wisconsin, Madison (United States); Stangeby, P. C. [University of Toronto Institute for Aerospace Studies, Toronto (Canada)

    2012-09-15

    Full text: A Fusion Nuclear Science Facility based on the Advanced Tokamak concept (FNSF-AT) [1] is a key element of a fast track plan to a commercially attractive fusion DEMO. The next step forward on the path towards fusion commercialization must be a device that complements ITER in addressing the community identified science and technology gaps to DEMO, and that enables a DEMO construction decision triggered by the achievement of Q = 10 in ITER, presently scheduled for the year 2030. This paper elucidates the logic flow leading to the FNSF-AT approach for such a next step forward, and presents the results of recent analysis resolving key physics and engineering issues. A FNSF-AT will show fusion can make its own fuel, provide a materials irradiation facility, show fusion can produce high-grade process heat and electricity. In order to accomplish these goals, the FNSF has to operate steady-state with significant duty cycle and significant neutron fluence. In FNSF-AT, advanced tokamak physics enables steady-state burning plasmas with the high fluence required for FNSF's nuclear science development objective, in the compact size required to demonstrate Tritium fuel self-sufficiency using only a moderate quantity of the limited supply of Tritium. Physics based integrated modeling has found a steady-state baseline equilibrium with good stability and controllability properties. 2-D analysis assuming ITER heat and particle diffusion coefficients in the SOL predicts peak heat flux < 10 MW/m{sup 2} at the outer divertor targets. High fidelity and high-resolution 3D neutronics calculations have also been carried out, showing acceptable cumulative end-of-life organic insulator dose levels in all the device coils, and TBR > 1 for two blanket concepts considered. This FNSF-AT baseline plasma scenario has significant margin to meet the FNSF nuclear science mission. Moreover, the facility allows the development of more advanced scenarios to close the physics gaps to DEMO

  17. Incidence of and risk factors for postoperative urinary retention in fast-track total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Bjerregaard, Lars; Bogø, Stina; Raaschou, Sofie

    2015-01-01

    BACKGROUND AND PURPOSE: Postoperative urinary retention (POUR) is a clinical challenge, but there is no scientific evidence for treatment principles. We describe the incidence of and predictive factors for POUR in fast-track total hip (THA) and knee arthroplasty (TKA). PATIENTS AND METHODS......, and preoperative international prostate symptom score (IPSS) were compared between catheterized and non-catheterized patients. RESULTS: The incidence of POUR was 40% (range between departments: 30-55%). Median bladder volume evacuated by catheterization was 0.6 (0.1-1.9) L. Spinal anesthesia increased the risk...... was 40%, with spinal anesthesia and increased IPSS in males as predictive factors. The large variation in perioperative bladder management and in bladder volumes evacuated by catheterization calls for randomized studies to define evidence-based principles for treatment of POUR in the future....

  18. Study of a Tracking/Preshower Detector for the LHC

    CERN Multimedia

    2002-01-01

    % RD-2 Study of a Tracking/Preshower Detector for the LHC \\\\ \\\\An important goal in the design of a detector to operate with high machine luminosity at the LHC is the detection of electrons at either the trigger or analysis level as a signature of rare physics processes. The purpose of this R~\\&~D activity is the study of track-stub/preshower techniques in electron identification. Activities include the study of radiation tolerance for silicon pad counters of the preshower detector, with the associated development of fast, low-noise, radiation hard and low-power electronics readout for the counters. The final aim is the construction of a prototype detector capable of operating at LHC.

  19. Development of fast ignition integrated interconnecting code (FI3) for fast ignition scheme

    International Nuclear Information System (INIS)

    Nagatomo, H.; Johzaki, T.; Mima, K.; Sunahara, A.; Nishihara, K.; Izawa, Y.; Sakagami, H.; Nakao, Y.; Yokota, T.; Taguchi, T.

    2005-01-01

    The numerical simulation plays an important role in estimating the feasibility and performance of the fast ignition. There are two key issues in numerical analysis for the fast ignition. One is the controlling the implosion dynamics to form a high density core plasma in non-spherical implosion, and the other is heating core plasma efficiency by the short pulse high intense laser. From initial laser irradiation to final fusion burning, all the physics are coupling strongly in any phase, and they must be solved consistently in computational simulation. However, in general, it is impossible to simulate laser plasma interaction and radiation hydrodynamics in a single computational code, without any numerical dissipation, special assumption or conditional treatment. Recently, we have developed 'Fast Ignition Integrated Interconnecting code' (FI 3 ) which consists of collective Particle-in-Cell code, Relativistic Fokker-Planck hydro code, and 2-dimensional radiation hydrodynamics code. And those codes are connecting with each other in data-flow bases. In this paper, we will present detail feature of the FI 3 code, and numerical results of whole process of fast ignition. (author)

  20. Development of requirements tracking and verification technology for the NPP software

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Chul Hwan; Kim, Jang Yeol; Lee, Jang Soo; Song, Soon Ja; Lee, Dong Young; Kwon, Kee Choon

    1998-12-30

    Searched and analyzed the technology of requirements engineering in the areas of aerospace and defense industry, medical industry and nuclear industry. Summarized the status of tools for the software design and requirements management. Analyzed the software design methodology for the safety software of NPP. Development of the design requirements for the requirements tracking and verification system. Development of the background technology to design the prototype tool for the requirements tracking and verification.

  1. Development of requirements tracking and verification technology for the NPP software

    International Nuclear Information System (INIS)

    Jung, Chul Hwan; Kim, Jang Yeol; Lee, Jang Soo; Song, Soon Ja; Lee, Dong Young; Kwon, Kee Choon

    1998-01-01

    Searched and analyzed the technology of requirements engineering in the areas of aerospace and defense industry, medical industry and nuclear industry. Summarized the status of tools for the software design and requirements management. Analyzed the software design methodology for the safety software of NPP. Development of the design requirements for the requirements tracking and verification system. Development of the background technology to design the prototype tool for the requirements tracking and verification

  2. Development of the Open Items Tracking System

    International Nuclear Information System (INIS)

    Riggi, V.

    1994-01-01

    The West Valley Demonstration Project, located on the site of the only commercial nuclear fuel reprocessing facility to have operated in USA, has the directed objectives of solidifying the high-level radioactive waste into a durable, solid form for shipment; decontaminating and decommissioning the tanks and facilities; and disposing of the resulting low-level and transuranic wastes. Since an escalating trend of open work items was noticed in the Fall of 1988, and there was no control mechanism for tracking and closing the open items, a Work Control System was developed for this purpose. It is self-contained system on a mainframe ARTEMIS 9000, which tracks, monitors, and closes out external commitments in a timely manner. Audits, surveillances, site appraisals, preventive maintenance, instrument calibration recall, and scheduling are covered

  3. Current status and perspective of advanced loop type fast reactor in fast reactor cycle technology development project

    International Nuclear Information System (INIS)

    Niwa, Hajime; Aoto, Kazumi; Morishita, Masaki

    2007-01-01

    After selecting the combination of the sodium-cooled fast reactor (SFR) with oxide fuel, the advanced aqueous reprocessing and the simplified pelletizing fuel fabrication as the most promising concept of FR cycle system, 'Feasibility Study on Commercialized Fast Reactor Cycle Systems' was finalized in 2006. Instead, a new project, Fast Reactor Cycle Technology Development Project (FaCT Project) was launched in Japan focusing on development of the selected concepts. This paper describes the current status and perspective of the advanced loop type SFR system in the FaCT Project, especially on the design requirements, current design as well as the related innovative technologies together with the development road-map. Some considerations on advantages of the advanced loop type design are also described. (authors)

  4. Development of Feedforward Control in a Dynamic Manual Tracking Task

    Science.gov (United States)

    van Roon, Dominique; Caeyenberghs, Karen; Swinnen, Stephan P.; Smits-Engelsman, Bouwien C. M.

    2008-01-01

    To examine the development of feedforward control during manual tracking, 117 participants in 5 age groups (6 to 7, 8 to 9, 10 to 11, 12 to 14, and 15 to 17 years) tracked an accelerating dot presented on a monitor by moving an electronic pen on a digitizer. To remain successful at higher target velocities, they had to create a predictive model of…

  5. Developing an electronic system to manage and track emergency medications.

    Science.gov (United States)

    Hamm, Mark W; Calabrese, Samuel V; Knoer, Scott J; Duty, Ashley M

    2018-03-01

    The development of a Web-based program to track and manage emergency medications with radio frequency identification (RFID) is described. At the Cleveland Clinic, medication kit restocking records and dispense locations were historically documented using a paper record-keeping system. The Cleveland Clinic investigated options to replace the paper-based tracking logs with a Web-based program that could track the real-time location and inventory of emergency medication kits. Vendor collaboration with a board of pharmacy (BOP) compliance inspector and pharmacy personnel resulted in the creation of a dual barcoding system using medication and pocket labels. The Web-based program was integrated with a Cleveland Clinic-developed asset tracking system using active RFID tags to give the real-time location of the medication kit. The Web-based program and the asset tracking system allowed identification of kits nearing expiration or containing recalled medications. Conversion from a paper-based system to a Web-based program began in October 2013. After 119 days, data were evaluated to assess the success of the conversion. Pharmacists spent an average of 27 minutes per day approving medication kits during the postimplementation period versus 102 minutes daily using the paper-based system, representing a 74% decrease in pharmacist time spent on this task. Prospective reports are generated monthly to allow the manager to assess the expected workload and adjust staffing for the next month. Implementation of a BOP-approved Web-based system for managing and tracking emergency medications with RFID integration decreased pharmacist review time, minimized compliance risk, and increased access to real-time data. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  6. Scalable Track Detection in SAR CCD Images

    Energy Technology Data Exchange (ETDEWEB)

    Chow, James G [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Quach, Tu-Thach [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-03-01

    Existing methods to detect vehicle tracks in coherent change detection images, a product of combining two synthetic aperture radar images ta ken at different times of the same scene, rely on simple, fast models to label track pixels. These models, however, are often too simple to capture natural track features such as continuity and parallelism. We present a simple convolutional network architecture consisting of a series of 3-by-3 convolutions to detect tracks. The network is trained end-to-end to learn natural track features entirely from data. The network is computationally efficient and improves the F-score on a standard dataset to 0.988, up fr om 0.907 obtained by the current state-of-the-art method.

  7. ACTS: from ATLAS software towards a common track reconstruction software

    Science.gov (United States)

    Gumpert, C.; Salzburger, A.; Kiehn, M.; Hrdinka, J.; Calace, N.; ATLAS Collaboration

    2017-10-01

    Reconstruction of charged particles’ trajectories is a crucial task for most particle physics experiments. The high instantaneous luminosity achieved at the LHC leads to a high number of proton-proton collisions per bunch crossing, which has put the track reconstruction software of the LHC experiments through a thorough test. Preserving track reconstruction performance under increasingly difficult experimental conditions, while keeping the usage of computational resources at a reasonable level, is an inherent problem for many HEP experiments. Exploiting concurrent algorithms and using multivariate techniques for track identification are the primary strategies to achieve that goal. Starting from current ATLAS software, the ACTS project aims to encapsulate track reconstruction software into a generic, framework- and experiment-independent software package. It provides a set of high-level algorithms and data structures for performing track reconstruction tasks as well as fast track simulation. The software is developed with special emphasis on thread-safety to support parallel execution of the code and data structures are optimised for vectorisation to speed up linear algebra operations. The implementation is agnostic to the details of the detection technologies and magnetic field configuration which makes it applicable to many different experiments.

  8. Characterization of plastic nuclear track detectors on solid state, CR-39 and LR-115 and its possibilities application on thermal and fast neutron dosimetry

    International Nuclear Information System (INIS)

    Vallejo Delgado, L.R.

    1989-01-01

    This work is an study about the use feasibility of plastic nuclear track detectors, LR 115, II-B (of Eastmann Kodak Co) and CR-39 (of American Acrylics and Plastics), for thermal and fast neutron dosimetry, respectively. The LR-115 with converter (n, alpha) was exposed to thermal neutrons with energy of 0,046 e V, proceeding from nuclear reactor RECH-1 of Nuclear Energy Chilean Commission. The irradiated films were submited to a chemical etching with NaOH, plus a washing and brushing. The CR-39 with polyethylene irradiator, was exposed to fast neutrons proceeding of calibrated sources of Am-Se. The irradiated plates were submited to a chemical pre-etching with KOH and a electrochemical post-etching. (author)

  9. The FastTrack Real Time Processor and Its Impact on Muon Isolation, Tau and b-Jet Online Selections at ATLAS

    CERN Document Server

    Crescioli, F; The ATLAS collaboration; Zhang, J; Boveia, A; Bevacqua, V; Cheng, Y; Canelli, F; Bogdan, M; Dell'Orso, M; Bossini, E; Citterio, M; Dunford, M; Drake, G; Beretta, M; Genat, JF; Annovi, A; Kim, YK; Kimura, N; Andreazza, A; Kapliy, A; Kasten, M; Piendibene, M; Negri, A; Meroni, C; Giannetti, P; Melachrinos, C; Hoff, J; Liberali, V; McCarn, A; Neubauer, M; Tang, F; Shochet, M; Stabile, A; Sartori, L; Sabatini, F; Proudfoot, J; Riva, M; Liu, T; Punzi, G; Vercesi, V; Tuggle, J; Todri, A; Tripiccione, R; Lanza, A; Wu, J; Yorita, K; Volpi, G; Vitullo, R.A; Sacco, I

    2010-01-01

    As the LHC luminosity is ramped up to 31034 cm−2 s−1 and beyond, the high rates, multiplicities, and energies of particles seen by the detectors will pose a unique challenge. Only a tiny fraction of the produced collisions can be stored on tape and immense real-time data reduction is needed. An effective trigger system must maintain high trigger efficiencies for the physics we are most interested in, and at the same time suppress the enormous QCD backgrounds. This requires massive computing power to minimize the online execution time of complex algorithms. A multi-level trigger is an effective solution for an otherwise impossible problem. The Fast Tracker (FTK) is a proposed upgrade to the current ATLAS trigger system that will operate at full Level-1 output rates and provide high quality tracks reconstructed over the entire detector by the start of processing in Level-2. FTK solves the combinatorial challenge inherent to tracking by exploiting massive parallelism of associative memories that can compa...

  10. Fast-tracking authentic leadership development by means of a programme

    Directory of Open Access Journals (Sweden)

    Tineke Wulffers

    2016-09-01

    Full Text Available Orientation: While there is considerable literature on the definition and impact of authentic leadership (AL, there is a research gap regarding the effectiveness of AL programmes. Research purpose: The focus of this article is on the proximal programme effect of an AL development programme on executive leaders within a period of 3 months. Motivation for the study: AL has been identified not only as the root construct of positive forms of leadership but also equates to the highest level of leadership effectiveness. Leadership authenticity can take a life time to develop, and organisations need positive and ethical leadership now. An appropriate AL programme could considerably shorten the development period of a such leadership Research design, approach and method: A longitudinal qualitative programme evaluation approach was used. The participants comprised a primary group of a 10-member executive leadership team who were the AL programme participants and their respective secondary (senior, peer and subordinate participants who provided pre- and post-programme data on the leadership authenticity of the primary participants. Main findings: The outline of the AL programme is presented with an indication of how it adhered to specific guidelines offered for development of such programmes. Findings indicate that the programme had a proximal effect of increasing AL; starting with the development of personal followed by interpersonal and professional leadership. Practical/managerial implications: An appropriate and effective AL programme could thus considerably shorten the development period of such leadership.

  11. Development of Non-Tracking Solar Thermal Technology

    Science.gov (United States)

    Winston, Roland; Johnston, Bruce; Balkowski, Kevin

    2011-11-01

    The aims of this research is to develop high temperature solar thermal collectors that do not require complex solar tracking devices to maintain optimal performance. The collector technology developed through these efforts uses non-imaging optics and is referred to as an external compound parabolic concentrator. It is able to operate with a solar thermal efficiency of approximately 50% at a temperature of 200 ° C and can be readily manufactured at a cost between 15 and 18 per square foot.

  12. Using track detectors in neutron dosimetry

    International Nuclear Information System (INIS)

    Spurny, F.; Turek, K.

    1977-01-01

    The usage of track detectors of charged particles provides a new possibility of neutron dosimetry. Presented is a comparison of the main dosimetric characteristics of three various types of track detectots of fast neutrons, i.e. glass in the contact with 232 Th; KODAK LR115 cellulose nitrate; MAKROFOL E polycarbonate. Results of studing energy dependences of detectors are presented. Results obtained using phantoms under radiation fields of various sources of complex gamma-neutron radiation are discussed [ru

  13. Developments of optical fast-gated imaging systems

    International Nuclear Information System (INIS)

    Koehler, H.A.; Kotecki, D.

    1984-08-01

    Several fast-gated imaging systems to measure ultra-fast single-transient data have been developed for time-resolved imaging of pulsed radiation sources. These systems were designed to achieve image recording times of 1 to 3 ms and dynamic ranges of >200:1 to produce large two-dimensional images (greater than or equal to 10 4 spatial points) of 1 to 2 ns exposure and small two-dimensional images (less than or equal to 200 spatial points) of less than or equal to 0.5 ns exposure. Both MCP intensified solid-state two-dimensional framing cameras and streak camera/solid-state camera systems were used; the framing camera system provides snap shots with high spatial resolution whereas the streak camera system provides for limited spatial points each with high temporal resolution. Applications of these systems include electron-beam, x-ray, gamma-ray, and neutron diagnostics. This report reviews the characteristics of the major components of fast-gated imaging systems developed at Lawrence Livermore National Laboratory. System performances are described in view of major experiments, and the diagnostic requirements of new experiments in atomic physics (x-ray lasers) and nuclear physics (fusion) are indicated

  14. Tracking a convoy of multiple targets using acoustic sensor data

    Science.gov (United States)

    Damarla, T. R.

    2003-08-01

    In this paper we present an algorithm to track a convoy of several targets in a scene using acoustic sensor array data. The tracking algorithm is based on template of the direction of arrival (DOA) angles for the leading target. Often the first target is the closest target to the sensor array and hence the loudest with good signal to noise ratio. Several steps were used to generate a template of the DOA angle for the leading target, namely, (a) the angle at the present instant should be close to the angle at the previous instant and (b) the angle at the present instant should be within error bounds of the predicted value based on the previous values. Once the template of the DOA angles of the leading target is developed, it is used to predict the DOA angle tracks of the remaining targets. In order to generate the tracks for the remaining targets, a track is established if the angles correspond to the initial track values of the first target. Second the time delay between the first track and the remaining tracks are estimated at the highest correlation points between the first track and the remaining tracks. As the vehicles move at different speeds the tracks either compress or expand depending on whether a target is moving fast or slow compared to the first target. The expansion and compression ratios are estimated and used to estimate the predicted DOA angle values of the remaining targets. Based on these predicted DOA angles of the remaining targets the DOA angles obtained from the MVDR or Incoherent MUSIC will be appropriately assigned to proper tracks. Several other rules were developed to avoid mixing the tracks. The algorithm is tested on data collected at Aberdeen Proving Ground with a convoy of 3, 4 and 5 vehicles. Some of the vehicles are tracked and some are wheeled vehicles. The tracking algorithm results are found to be good. The results will be presented at the conference and in the paper.

  15. Fast neutron spectrometry based on proton detection in CR-39 detector

    Energy Technology Data Exchange (ETDEWEB)

    Dajko, G.; Somogyi, G.

    1986-01-01

    The authors have developed a home-made proton-sensitive CR-39 track detector called MA-ND/p. Using this and the n-p scattering process the performance of a fast neutron spectrometer has been studied by applying two different methods. These are based on track density determinations by using varying radiator thicknesses at constant etching time and by using varying etching times at fixed radiator thickness, respectively. For both methods studied a computer programme is made to calculate the theoretically expected neutron sensitivity as a function of neutron energy. For both methods the neutron sensitivities, expressed in terms of observable etched proton tracks per neutron, are determined experimentally for 3.3 and 14.7 MeV neutron energies. The theoretical and experimental data obtained are compared.

  16. Fast neutron spectrometry based on proton detection in CR-39 detector

    International Nuclear Information System (INIS)

    Dajko, G.; Somogyi, G.

    1986-01-01

    The authors have developed a home-made proton-sensitive CR-39 track detector called MA-ND/p. Using this and the n-p scattering process the performance of a fast neutron spectrometer has been studied by applying two different methods. These are based on track density determinations by using varying radiator thicknesses at constant etching time and by using varying etching times at fixed radiator thickness, respectively. For both methods studied a computer programme is made to calculate the theoretically expected neutron sensitivity as a function of neutron energy. For both methods the neutron sensitivities, expressed in terms of observable etched proton tracks per neutron, are determined experimentally for 3.3 and 14.7 MeV neutron energies. The theoretical and experimental data obtained are compared. (author)

  17. The effect of Ramadan fasting on fetal development.

    Science.gov (United States)

    Karateke, Atilla; Kaplanoglu, Mustafa; Avci, Fazil; Kurt, Raziye Keskin; Baloglu, Ali

    2015-01-01

    To evaluate the effects of Ramadan fasting on fetal development and outcomes of pregnancy. We performed this study in Antakya State Hospital of Obstetrics and Child Care, between 28 June 2014 and 27 July 2014 (during the month of Ramadan). A total of two hundred forty healthy pregnant women who were fasting during Ramadan, were included in the groups. The three groups were divided according to the trimesters. The each group was consisted of 40 healthy pregnant women with fasting and 40 healthy pregnant women without fasting. For evaluating the effects of Ramadan on fetus, ultrasonography was performed on all pregnant women in the beginning and the end of Ramadan. We used the essential parameters for the following measurements: increase of fetal biparietal diameter (BPD), increase of fetal femur length (FL), increase of estimated fetal body weight (EFBW), fetal biophysical profile (BPP), amniotic fluid index (AFI), and umbilical artery systole/diastole (S/D) ratio. No significant difference was found between the two groups for the fetal age, maternal weight gain (kilogram), estimated fetal weight gain (EFWG), fetal BPP, AFI, and umbilical artery S/D ratio. On the other hand, a statistically significant increase was observed in maternal weight in the second and third trimesters and a significant increase was observed in the amniotic fluid index in second trimester. In Ramadan there was no bad fetal outcome between pregnant women with fasting and pregnant women without fasting. Pregnant women who want to be with fast, should be examined by doctors, adequately get breakfast before starting to fast and after the fasting take essential calori and hydration. More comprehensive randomized studies are needed to explain the effects of fasting on the pregnancy and fetal outcomes.

  18. Successful talent development in track and field

    DEFF Research Database (Denmark)

    Henriksen, K; Stambulova, N; Roessler, K K

    2010-01-01

    Track and field includes a number of high-intensity disciplines with many demanding practices and represents a motivational challenge for talented athletes aiming to make a successful transition to the senior elite level. Based on a holistic ecological approach, this study presents an analysis...... of a particular athletic talent development environment, the IFK Växjö track and field club, and examines key factors behind its successful history of creating top-level athletes. The research takes the form of a case study. Data were collected from multiple perspectives (in-depth interviews with administrators...... to elite athletes. A strong organizational culture, characterized by values of open co-operation, by a focus on performance process and by a whole-person approach, provided an important basis for the environment's success. The holistic ecological approach encourages practitioners to broaden their focus...

  19. New approach of modeling charged particles track development in CR-39 detectors

    International Nuclear Information System (INIS)

    Azooz, A.A.; Hermsdorf, D.; Al-Jubbori, M.A.

    2013-01-01

    In this work, previous modeling of protons and alpha particles track length development in CR-39 solid state nuclear track detectors SSNTD is modified and further extended. The extension involved the accommodation of heavier ions into the model. These ions include deuteron, lithium, boron, carbon, nitrogen and oxygen ions. The new modeling does not contain any case sensitive free fitting parameters. Model calculation results are found to be in good agreement with both experimental data and SRIM software range energy dependence predictions. The access to a single unified and differentiable track length development equation results in the ability to obtain direct results for track etching rates. - Highlights: • New modeling of ions track length evolution measured by different authors. • Ions considered are p, d, α, Li, B, C, N, O. • Equations obtained to describe L(t) and etch rate for all ions at wide energy range. • Equations obtained do not involve any free fitting parameters. • Ions range values obtained compare well with results of SRIM software

  20. Status of fast breeder reactor development in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, S

    1979-07-01

    This document was prepared by the Office of the Program Director for Nuclear Energy, U.S. Department of Energy (USDOE). It sets forth the status and current activities for the development of fast breeder technology in the United States. In April 1977 the United States announced a change in its nuclear energy policy. Concern about the potential for the proliferation of nuclear weapons capability emerged as a major issue in considering whether to proceed with the development, demonstration and eventual deployment of breeder reactor energy systems. Plutonium recycle and the commercialization of the fast breeder were deferred indefinitely. This led to a reorientation of the nuclear fuel cycle program which was previously directed toward the commercialization of fuel reprocessing and plutonium recycle to the investigation of a full range of alternative fuel cycle technologies. Two major system evaluation programs, the Nonproliferation Alternative Systems Assessment Program (NASAP), which is domestic, and the International Nuclear Fuel Cycle Evaluation (INFCE), which is international, are assessing the nonproliferation advantages and other characteristics of advanced reactor concepts and fuel cycles. These evaluations will allow a decision in 1981 on the future direction of the breeder program. In the interim, the technologies of two fast breeder reactor concepts are being developed: the Liquid Metal Fast Breeder Reactor (LMFBR) and the Gas Cooled Fast Reactor (CFR). The principal goals of the fast breeder program are: LMFBR - through a strong R and D program, consistent with US nonproliferation objectives and anticipated national electric energy requirements, maintain the capability to commit to a breeder option; investigate alternative fuels and fuel cycles that might offer nonproliferation advantages; GCFR - provide a viable alternative to the LMFBR that will be consistent with the developing U.S. nonproliferation policy; provide GCFR technology and other needed

  1. Research on Fast Track Surgery Application in Lung Cancer Surgery

    Directory of Open Access Journals (Sweden)

    Kaiyun YANG

    2010-02-01

    Full Text Available Background and objective Fast track surgery (FTS is a systematical method to accelerate the recovery of surgical patients by reducing the physical and mental trauma stress of them. The research is to investigate the feasibility of FTS application in lung cancer surgery. Methods A total of 80 cases of lung cancer patients with single leaf lobotomy resection were randomized into two groups. While the experimental group was treated with the conception of FTS, and the control group was treated with the traditional methods. The incident rate of post-operation pain degrees, telecasts, pleural effusion, the post-operation time stay in hospital time and the total cost during hospitalization in two groups were compared respectively. Results In FTS group: the VAS score of post-operation pain at 1 h, 6 h, 12 h, 24 h and 48 h all significantly decreased compared to the traditional therapy group. The incidence rate of telecast was 10.53%. The incidence rate of pleural effusion was 26.31%. The length of stay after operation was (4±1 d and the total cost was RMB 15 600±7 600. In the control group, the above values were 77.78%, 33.33%, 22.22%, (9±1 d, RMB 23 600±5 400, respectively. The post operation pain (VAS method of FTS group was remarkablely below the control group. There has significant difference of the incident rate of telecasts, stay time in hospital and the total cast in two groups (P < 0.05. No significant difference was observed in the incident rate of pleural effusion. Conclusion The new methods of FTS can apparently accelerates recovery after lung cancer resection, reduces complications, shorten timestay in hospital and cut down the total cost.

  2. Recent Developments in the Code RITRACKS (Relativistic Ion Tracks)

    Science.gov (United States)

    Plante, Ianik; Ponomarev, Artem L.; Blattnig, Steve R.

    2018-01-01

    The code RITRACKS (Relativistic Ion Tracks) was developed to simulate detailed stochastic radiation track structures of ions of different types and energies. Many new capabilities were added to the code during the recent years. Several options were added to specify the times at which the tracks appear in the irradiated volume, allowing the simulation of dose-rate effects. The code has been used to simulate energy deposition in several targets: spherical, ellipsoidal and cylindrical. More recently, density changes as well as a spherical shell were implemented for spherical targets, in order to simulate energy deposition in walled tissue equivalent proportional counters. RITRACKS is used as a part of the new program BDSTracks (Biological Damage by Stochastic Tracks) to simulate several types of chromosome aberrations in various irradiation conditions. The simulation of damage to various DNA structures (linear and chromatin fiber) by direct and indirect effects has been improved and is ongoing. Many improvements were also made to the graphic user interface (GUI), including the addition of several labels allowing changes of units. A new GUI has been added to display the electron ejection vectors. The parallel calculation capabilities, notably the pre- and post-simulation processing on Windows and Linux machines have been reviewed to make them more portable between different systems. The calculation part is currently maintained in an Atlassian Stash® repository for code tracking and possibly future collaboration.

  3. Data-Base Software For Tracking Technological Developments

    Science.gov (United States)

    Aliberti, James A.; Wright, Simon; Monteith, Steve K.

    1996-01-01

    Technology Tracking System (TechTracS) computer program developed for use in storing and retrieving information on technology and related patent information developed under auspices of NASA Headquarters and NASA's field centers. Contents of data base include multiple scanned still images and quick-time movies as well as text. TechTracS includes word-processing, report-editing, chart-and-graph-editing, and search-editing subprograms. Extensive keyword searching capabilities enable rapid location of technologies, innovators, and companies. System performs routine functions automatically and serves multiple users.

  4. A prospective cohort study to investigate cost-minimisation, of Traditional open, open fAst track recovery and laParoscopic fASt track multimodal management, for surgical patients with colon carcinomas (TAPAS study).

    NARCIS (Netherlands)

    Reurings, J.C.; Spanjersberg, W.R.; Oostvogel, H.J.M.; Buskens, E.; Maring, J.; Kruijt, F.; Rosman, C.; Duivendijk, P. van; Dejong, C.H.; Laarhoven, C.J.H.M. van

    2010-01-01

    BACKGROUND: The present developments in colon surgery are characterized by two innovations: the introduction of the laparoscopic operation technique and fast recovery programs such as the Enhanced Recovery After Surgery (ERAS) recovery program. The Tapas-study was conceived to determine which of the

  5. Development of a fast agglutination screening test (FAST) for the detection of anti-Leishmania antibodies in dogs

    NARCIS (Netherlands)

    Schallig, H. D. F. H.; Schoone, G. J.; Beijer, E. G. M.; Kroon, C. C. M.; Hommers, M.; Ozbel, Y.; Ozensoy, S.; da Silva, E. S.; Cardoso, L. M.; da Silva, E. D.

    2002-01-01

    A fast agglutination screening test (FAST) for the detection of anti-Leishinania antibodies in serum samples from dogs with visceral leishmamosis was developed. The test is based on the direct agglutination test (DAT), but combines a higher parasite concentration with a smaller test volume. In

  6. Aspects of the physics and chemistry of water radiolysis by fast neutrons and fast electrons in nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    McCracken, D.R. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Tsang, K.T. [Atomic Energy of Canada Limited, Mississauga, Ontario (Canada); Laughton, P.J

    1998-09-01

    Detailed radiation physics calculations of energy deposition have been done for the coolant of CANDU reactors and Pressurized Water Reactors (PWRs). The geometry of the CANDU fuel channel was modelled in detail. Fluxes and energy-deposition rates for neutrons, recoil ions, photons, and fast electrons have been calculated using MCNP4B, WIMS-AECL, and specifically derived energy-transfer factors. These factors generate the energy/flux spectra of recoil ions from fast-neutron energy/flux spectra. The energy spectrum was divided into 89 discrete ranges (energy bins).The production of oxidizing species and net coolant radiolysis can be suppressed by the addition of hydrogen to the coolant of nuclear reactors. It is argued that the net dissociation of coolant by gamma rays is suppressed by lower levels of excess hydrogen than when dissociation is by ion recoils. This has consequences for the modelling of coolant radiolysis by homogeneous kinetics. More added hydrogen is required to stop water radiolysis by recoil ions acting alone than if recoil ions and gamma rays acted concurrently in space and time. Homogeneous kinetic models and experimental data suggest that track overlap is very inefficient in providing radicals from gamma-ray tracks to recombine molecular products in ion-recoil tracks. An inhomogeneous chemical model is needed that incorporates ionizing-particle track structure and track overlap. Such a model does not yet exist, but a number of limiting cases using homogeneous kinetics are discussed. There are sufficient uncertainties and contradictions in the data relevant to the radiolysis of reactor coolant that the relatively high CHC's (critical hydrogen concentration) observed in NRU reactor experiments (compared to model predictions) may be explainable by errors in fundamental data and understanding of water radiolysis under reactor conditions. The radiation chemistry program at CRL has been focused to generate quantitative water-radiolysis data in a

  7. The ATLAS Fast TracKer Processing Units

    CERN Document Server

    Krizka, Karol; The ATLAS collaboration

    2016-01-01

    The Fast Tracker is a hardware upgrade to the ATLAS trigger and data-acquisition system, with the goal of providing global track reconstruction by the start of the High Level Trigger starts. The Fast Tracker can process incoming data from the whole inner detector at full first level trigger rate, up to 100 kHz, using custom electronic boards. At the core of the system is a Processing Unit installed in a VMEbus crate, formed by two sets of boards: the Associative Memory Board and a powerful rear transition module called the Auxiliary card, while the second set is the Second Stage board. The associative memories perform the pattern matching looking for correlations within the incoming data, compatible with track candidates at coarse resolution. The pattern matching task is performed using custom application specific integrated circuits, called associative memory chips. The auxiliary card prepares the input and reject bad track candidates obtained from from the Associative Memory Board using the full precision a...

  8. Gas cooled fast reactor research and development program

    International Nuclear Information System (INIS)

    Markoczy, G.; Hudina, M.; Richmond, R.; Wydler, P.; Stratton, R.W.; Burgsmueller, P.

    1980-03-01

    The research and development work in the field of core thermal-hydraulics, steam generator research and development, experimental and analytical physics and carbide fuel development carried out 1979 for the Gas Cooled Fast Breeder Reactor at the Swiss Federal Institute for Reactor Research is described. (Auth.)

  9. Finding very small near-Earth asteroids using synthetic tracking

    International Nuclear Information System (INIS)

    Shao, Michael; Nemati, Bijan; Zhai, Chengxing; Turyshev, Slava G.; Sandhu, Jagmit; Hallinan, Gregg; Harding, Leon K.

    2014-01-01

    We present an approach that significantly increases the sensitivity for finding and tracking small and fast near-Earth asteroids (NEAs). This approach relies on a combined use of a new generation of high-speed cameras which allow short, high frame-rate exposures of moving objects, effectively 'freezing' their motion, and a computationally enhanced implementation of the 'shift-and-add' data processing technique that helps to improve the signal-to-noise ratio (SNR) for detection of NEAs. The SNR of a single short exposure of a dim NEA is insufficient to detect it in one frame, but by computationally searching for an appropriate velocity vector, shifting successive frames relative to each other and then co-adding the shifted frames in post-processing, we synthetically create a long-exposure image as if the telescope were tracking the object. This approach, which we call 'synthetic tracking,' enhances the familiar shift-and-add technique with the ability to do a wide blind search, detect, and track dim and fast-moving NEAs in near real time. We discuss also how synthetic tracking improves the astrometry of fast-moving NEAs. We apply this technique to observations of two known asteroids conducted on the Palomar 200 inch telescope and demonstrate improved SNR and 10 fold improvement of astrometric precision over the traditional long-exposure approach. In the past 5 yr, about 150 NEAs with absolute magnitudes H = 28 (∼10 m in size) or fainter have been discovered. With an upgraded version of our camera and a field of view of (28 arcmin) 2 on the Palomar 200 inch telescope, synthetic tracking could allow detecting up to 180 such objects per night, including very small NEAs with sizes down to 7 m.

  10. Finding very small near-Earth asteroids using synthetic tracking

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Michael; Nemati, Bijan; Zhai, Chengxing; Turyshev, Slava G.; Sandhu, Jagmit [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109-0899 (United States); Hallinan, Gregg; Harding, Leon K. [California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 (United States)

    2014-02-10

    We present an approach that significantly increases the sensitivity for finding and tracking small and fast near-Earth asteroids (NEAs). This approach relies on a combined use of a new generation of high-speed cameras which allow short, high frame-rate exposures of moving objects, effectively 'freezing' their motion, and a computationally enhanced implementation of the 'shift-and-add' data processing technique that helps to improve the signal-to-noise ratio (SNR) for detection of NEAs. The SNR of a single short exposure of a dim NEA is insufficient to detect it in one frame, but by computationally searching for an appropriate velocity vector, shifting successive frames relative to each other and then co-adding the shifted frames in post-processing, we synthetically create a long-exposure image as if the telescope were tracking the object. This approach, which we call 'synthetic tracking,' enhances the familiar shift-and-add technique with the ability to do a wide blind search, detect, and track dim and fast-moving NEAs in near real time. We discuss also how synthetic tracking improves the astrometry of fast-moving NEAs. We apply this technique to observations of two known asteroids conducted on the Palomar 200 inch telescope and demonstrate improved SNR and 10 fold improvement of astrometric precision over the traditional long-exposure approach. In the past 5 yr, about 150 NEAs with absolute magnitudes H = 28 (∼10 m in size) or fainter have been discovered. With an upgraded version of our camera and a field of view of (28 arcmin){sup 2} on the Palomar 200 inch telescope, synthetic tracking could allow detecting up to 180 such objects per night, including very small NEAs with sizes down to 7 m.

  11. Effect of track etch rate on geometric track characteristics for polymeric track detectors

    International Nuclear Information System (INIS)

    Abdel-Naby, A.A.; El-Akkad, F.A.

    2001-01-01

    Analysis of the variable track etch rate on geometric track characteristic for polymeric track detectors has been applied to the case of LR-155 II SSNTD. Spectrometric characteristics of low energy alpha particles response by the polymeric detector have been obtained. The track etching kinematics theory of development of minor diameter of the etched tracks has been applied. The calculations show that, for this type of detector, the energy dependence of the minor track diameter d is linear for small-etched removal layer h. The energy resolution gets better for higher etched removal layer

  12. Fast-track surgery protocol in elderly patients undergoing laparoscopic radical gastrectomy for gastric cancer: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Liu G

    2016-06-01

    Full Text Available Guozheng Liu,1 Fengguo Jian,2 Xiuqin Wang,2 Lin Chen1 1Department of General Surgery, Chinese PLA General Hospital, Beijing, People’s Republic of China; 2Second Department of General Surgery, Changyi People’s Hospital, Shandong, People’s Republic of China Aim: To study the efficacy of the fast-track surgery (FTS program combined with laparoscopic radical gastrectomy for elderly gastric cancer (GC patients.Methods: Eighty-four elderly patients diagnosed with GC between September 2014 and August 2015 were recruited to participate in this study and were divided into four groups randomly based on the random number table as follows: FTS + laparoscopic group (Group A, n=21, FTS + laparotomy group (Group B, n=21, conventional perioperative care (CC + laparoscopic group (Group C, n=21, and CC + laparotomy group (Group D, n=21. Observation indicators include intrasurgery indicators, postoperative recovery indicators, nutritional status indicators, and systemic stress response indicators.Results: Preoperative and intraoperative baseline characteristics showed no significant differences between patients in each group (P>0.05. There were no significant differences between each group in nausea and vomiting, intestinal obstruction, urinary retention, incision infection, pulmonary infection, and urinary tract infection after operation (P>0.05. Time of first flatus and postoperative hospital stay time of FTS Group A were the shortest, and total medical cost of this group was the lowest. For all groups, serum albumin, prealbumin, and transferrin significantly decreased, while CRP and interleukin 6 were significantly increased postoperative day 1. From postoperative day 4–7, all indicators of the four groups gradually recovered, but compared with other three groups, those of Group A recovered fastest.Conclusion: FTS combined with laparoscopic surgery can promote faster postoperative recovery, improve early postoperative nutritional status, and more

  13. SU-F-T-370: A Fast Monte Carlo Dose Engine for Gamma Knife

    Energy Technology Data Exchange (ETDEWEB)

    Song, T; Zhou, L [Southern Medical University, Guangzhou, Guangdong (China); Li, Y [Beihang University, Beijing, Beijing (China)

    2016-06-15

    Purpose: To develop a fast Monte Carlo dose calculation algorithm for Gamma Knife. Methods: To make the simulation more efficient, we implemented the track repeating technique on GPU. We first use EGSnrc to pre-calculate the photon and secondary electron tracks in water from two mono-energy photons of 60Co. The total photon mean free paths for different materials and energies are obtained from NIST. During simulation, each entire photon track was first loaded to shared memory for each block, the incident original photon was then splitted to Nthread sub-photons, each thread transport one sub-photon, the Russian roulette technique was applied for scattered and bremsstrahlung photons. The resultant electrons from photon interactions are simulated by repeating the recorded electron tracks. The electron step length is stretched/shrunk proportionally based on the local density and stopping power ratios of the local material. Energy deposition in a voxel is proportional to the fraction of the equivalent step length in that voxel. To evaluate its accuracy, dose deposition in a 300mm*300mm*300mm water phantom is calculated, and compared to EGSnrc results. Results: Both PDD and OAR showed great agreements (within 0.5%) between our dose engine result and the EGSnrc result. It only takes less than 1 min for every simulation, being reduced up to ∼40 times compared to EGSnrc simulations. Conclusion: We have successfully developed a fast Monte Carlo dose engine for Gamma Knife.

  14. Deformable Models for Eye Tracking

    DEFF Research Database (Denmark)

    Vester-Christensen, Martin; Leimberg, Denis; Ersbøll, Bjarne Kjær

    2005-01-01

    A deformable template method for eye tracking on full face images is presented. The strengths of the method are that it is fast and retains accuracy independently of the resolution. We compare the me\\$\\backslash\\$-thod with a state of the art active contour approach, showing that the heuristic...

  15. Development of Bushing Compounds for Tracked Vehicles

    Science.gov (United States)

    1990-10-01

    unwanted stepchild - part of called anti patented NBR -12 formulation the family (system), but devoid of needed indicated that service life could be...as Development and Engineering Center’s long. Bushings currently used in the M I track Rubber and Coated Fabrics Research Group assembly typically fail...formulations of should be improved. Numerous selected candidate natural rubber , propylene formulations-based on natural rubber , oxide, and silicone

  16. History of fast reactor fuel development

    Energy Technology Data Exchange (ETDEWEB)

    Kittel, J.H. (Argonne National Lab., IL (United States)); Frost, B.R.T. (Argonne National Lab., IL (United States)); Mustelier, J.P. (COGEMA, Velizy-Villacoublay (France)); Bagley, K.Q. (AEA Reactor Services, Risley (United Kingdom)); Crittenden, G.C. (AEA Reactor Services, Dounreay (United Kingdom)); Dievoet, J. van (Belgonucleaire, Brussels (Belgium))

    1993-09-01

    The first fast breeder eactors, constructed in the 1945-1960 time period, used metallic fuels composed of uranium, plutonium, or their alloys. They were chosen because most existing reactor operating experience had been obtained on metallic fuels and because they provided the highest breeding ratios. Difficulties in obtaining adequate dimensional stability in metallic fuel elements under conditions of high fuel burnup led in the 1960s to the virtual worldwide choice of ceramic fuels. Although ceramic fuels provide lower breeding performance, this objective is no longer an important consideration in most national programs. Mixed uranium and plutonium dioxide became the ceramic fuel that has received the widest use. The more advanced ceramic fuels, mixed uranium and plutonium carbides and nitrides, continue under development. More recently, metal fuel elements of improved design have joined ceramic fuels in achieving goal burnups of 15 to 20 percent. Low-swelling fuel cladding alloys have also been continuously developed to deal with the unexpected problem of void formation in stainless steels subjected to fast neutron irradiation, a phenomenon first observed in the 1960s. (orig.)

  17. Development and validation of a two-dimensional fast-response flood estimation model

    Energy Technology Data Exchange (ETDEWEB)

    Judi, David R [Los Alamos National Laboratory; Mcpherson, Timothy N [Los Alamos National Laboratory; Burian, Steven J [UNIV OF UTAK

    2009-01-01

    A finite difference formulation of the shallow water equations using an upwind differencing method was developed maintaining computational efficiency and accuracy such that it can be used as a fast-response flood estimation tool. The model was validated using both laboratory controlled experiments and an actual dam breach. Through the laboratory experiments, the model was shown to give good estimations of depth and velocity when compared to the measured data, as well as when compared to a more complex two-dimensional model. Additionally, the model was compared to high water mark data obtained from the failure of the Taum Sauk dam. The simulated inundation extent agreed well with the observed extent, with the most notable differences resulting from the inability to model sediment transport. The results of these validation studies complex two-dimensional model. Additionally, the model was compared to high water mark data obtained from the failure of the Taum Sauk dam. The simulated inundation extent agreed well with the observed extent, with the most notable differences resulting from the inability to model sediment transport. The results of these validation studies show that a relatively numerical scheme used to solve the complete shallow water equations can be used to accurately estimate flood inundation. Future work will focus on further reducing the computation time needed to provide flood inundation estimates for fast-response analyses. This will be accomplished through the efficient use of multi-core, multi-processor computers coupled with an efficient domain-tracking algorithm, as well as an understanding of the impacts of grid resolution on model results.

  18. The ATLAS Fast Tracker

    CERN Document Server

    Volpi, Guido; The ATLAS collaboration

    2015-01-01

    The use of tracking information at the trigger level in the LHC Run II period is crucial for the trigger an data acquisition (TDAQ) system. The tracking precision is in fact important to identify specific decay products of the Higgs boson or new phenomena, a well as to distinguish the contributions coming from many contemporary collisions that occur at every bunch crossing. However, the track reconstruction is among the most demanding tasks performed by the TDAQ computing farm; in fact, full reconstruction at full Level-1 trigger accept rate (100 KHz) is not possible. In order to overcome this limitation, the ATLAS experiment is planning the installation of a specific processor: the Fast Tracker (FTK), which is aimed at achieving this goal. The FTK is a pipeline of high performance electronic, based on custom and commercial devices, which is expected to reconstruct, with high resolution, the trajectories of charged tracks with a transverse momentum above 1 GeV, using the ATLAS inner tracker information. Patte...

  19. The design and construction of the ZEUS central tracking detector

    Energy Technology Data Exchange (ETDEWEB)

    Foster, B.; Malos, J.; Saxon, D.H.; Clark, D.E.; Jamdagni, A.K.; Markou, C.; Miller, D.B.; Miller, D.G.; Toudup, L.W.; Auty, C.G.; Blair, G.A.; Brooks, C.B.; Cashmore, R.J.; Hanford, A.T.; Harnew, N.; Holmes, A.R.; Linford, W.; Martin, N.C.; McArthur, I.C.; Nash, J.; Nobbs, K.N.; Wastie, R.L.; Williams, M.T.; Wilson, F.F.; Wilson, R.D.; Hart, J.C.; Hatley, R.W.; Hiddleston, J.W.; Gibson, M.D.; McCubbin, N.A.; Middleton, A.; Morrissey, M.C.; Morrow, D.; O' Brien, P.; Payne, B.T.; Roberts, J.C.H.; Shaw, T.B.; Sinclair, C.K.; Wallis, E.W.G.; White, D.J.; Yeo, K.L.; Bullock, F.W.; Dumper, J.; Fraser, T.J.; Hayes, D.; Jones, T.W.; Strachan, D.E.; Vine, I.A. (H.H. Wills Physics Lab., Univ. of Bristol (United Kingdom) Dept. of Physics and Astronomy, Univ. of Glasgow (United Kingdom) Blackett Lab., Physics Dept., Imperial Coll., London (United Kingdom) Dept. of Physics, Nuclear Physics Lab., Univ. of Oxford (United Kingdom) Rutherford Appleton Lab., Chilton (United Kingdom) Dept. of Physics an

    1994-01-15

    The mechanical, electrical and electronic design and construction of the ZEUS central tracking detector are described, together with the chamber monitoring and environmental control. This cylindrical drift chamber is designed for track reconstruction, electron identification and fast event triggering in a high beam-crossing rate, high magnetic field application. (orig.)

  20. Fast track segment finding in the Monitored Drift Tubes of the ATLAS Muon Spectrometer using a Legendre transform algorithm

    CERN Document Server

    Ntekas, Konstantinos; The ATLAS collaboration

    2018-01-01

    The upgrade of the ATLAS first-level muon trigger for High- Luminosity LHC foresees incorporating the precise tracking of the Monitored Drift Tubes in the current system based on Resistive Plate Chambers and Thin Gap Chambers to improve the accuracy in the transverse momentum measurement and control the single muon trigger rate by suppressing low quality fake triggers. The core of the MDT trigger algorithm is the segment identification and reconstruction which is performed per MDT chamber. The reconstructed segment positions and directions are then combined to extract the muon candidate’s transverse momentum. A fast pattern recognition segment finding algorithm, called the Legendre transform, is proposed to be used for the MDT trigger, implemented in a FPGA housed on a ATCA blade.

  1. Fast region-based object detection and tracking using correlation of features

    CSIR Research Space (South Africa)

    Senekal, F

    2010-11-01

    Full Text Available and track a target object (or objects) over a series of digital images. Visual target tracking can be accomplished by feature-based or region-based approaches. In feature-based approaches, interest points are calculated in a digital image, and a local...-time performance based on the computational power that is available on a specific platform. To further reduce the computational requirements, process- ing is restricted to the region of interest (ROI). The region of interest is provided as an input parameter...

  2. FTK: A Hardware Track Finder for the ATLAS Trigger System

    CERN Document Server

    Tompkins, L; The ATLAS collaboration

    2013-01-01

    The LHC experiments are preparing for instantaneous luminosities above $1 imes 10^{34} cm^{-2}s^{-1}$ as early as 2015. In order to select the rare events of interest in such dense environments, detailed event information is necessary. In particular, the highly granular single particle information of tracking detectors is crucial for the selection of isolated leptons, taus and b-jets in the face of large vertex multiplicities. We report on the developement of the ATLAS FastTracker (FTK), a hardware based track finder which will reconstruct all tracks with a momentum greater than 1 GeV/c up to luminosties of $3 imes 10^{34} cm^{-2}s^{-1}$ at an event input rate of 100 kHz and a latency of a few hundred microseconds. The track information will be available to the Level 2 processors at the beginning of event processing. Significant progress towards a phased installation beginning in 2015 has been achieved. A pre-prototype of the pattern recognition board is taking data in the fall of 2012 and prototypes for all ...

  3. The ATLAS Fast Tracker Processing Units - input and output data preparation

    CERN Document Server

    Bolz, Arthur; Adelman, Jahred; Anderson, John Thomas; Armbruster, Aaron James; Asbah, Nedaa; Blair, Robert; Brost, Elizabeth; Drake, Gary; Gkaitatzis, Stamatios; Iizawa, Tomoya; Ilic, Nikolina; Jiang, Zihao; Kawaguchi, Yoshimasa; Kimura, Naoki; Kordas, Kostantinos; Sotiropoulou, Calliope Louisa; Love, Jeremy; Mitani, Takashi; Nikolaidis, Spyridon; Okumura, Yasuyuki; Proudfoot, James; Thayil, Steffie Ann; Tompkins, Lauren; Wang, Rui; Watari, Ryutaro; Webster, Jordan S; Yorita, Kohei; Zhang, Jinlong

    2017-01-01

    The ATLAS Fast TracKer(FTK) is a custom hardware system for fast, associative memory based track reconstruction. It will provide tracking information within the full acceptance of the inner tracking detectors to the high level trigger at a rate of up to 100 kHz. %, thus allowing for a refined and more efficient event selection at the trigger level. At the first stage of the FTK the Data Formatter subsystem clusters inner detector hits and organizes them into 64 $\\eta$-$\\phi$ trigger regions. At the last stage, the FTK to Level-2 Interface Cards repackage track records and send them to the high level trigger computing farm. This report aims to give an overview over the functionality of the two systems, their hardware implementation in the Advanced Telecommunications Computing Architecture standard, and the status of their integration into ATLAS.

  4. The ATLAS Fast Tracker Processing Units - input and output data preparation

    CERN Document Server

    Bolz, Arthur; Adelman, Jahred; Anderson, John Thomas; Armbruster, Aaron James; Asbah, Nedaa; Blair, Robert; Brost, Elizabeth; Drake, Gary; Gkaitatzis, Stamatios; Iizawa, Tomoya; Ilic, Nikolina; Jiang, Zihao; Kawaguchi, Yoshimasa; Kimura, Naoki; Kordas, Kostantinos; Sotiropoulou, Calliope Louisa; Love, Jeremy; Mitani, Takashi; Nikolaidis, Spyridon; Okumura, Yasuyuki; Proudfoot, James; Thayil, Steffie Ann; Tompkins, Lauren; Wang, Rui; Watari, Ryutaro; Webster, Jordan S; Yorita, Kohei; Zhang, Jinlong

    2016-01-01

    The ATLAS Fast TracKer(FTK) is a custom hardware system for fast, associative memory based track reconstruction. It will provide tracking information within the full acceptance of the inner tracking detectors to the high level trigger at a rate of up to 100 kHz. %, thus allowing for a refined and more efficient event selection at the trigger level. At the first stage of the FTK the Data Formatter subsystem clusters inner detector hits and organizes them into 64 $\\eta$-$\\phi$ trigger regions. At the last stage, the FTK to Level-2 Interface Cards repackage track records and send them to the high level trigger computing farm. This report aims to give an overview over the functionality of the two systems, their hardware implementation in the Advanced Telecommunications Computing Architecture standard, and the status of their integration into ATLAS.

  5. Parameterization-based tracking for the P2 experiment

    Science.gov (United States)

    Sorokin, Iurii

    2017-08-01

    The P2 experiment in Mainz aims to determine the weak mixing angle θW at low momentum transfer by measuring the parity-violating asymmetry of elastic electronproton scattering. In order to achieve the intended precision of Δ(sin2 θW)/sin2θW = 0:13% within the planned 10 000 hours of running the experiment has to operate at the rate of 1011 detected electrons per second. Although it is not required to measure the kinematic parameters of each individual electron, every attempt is made to achieve the highest possible throughput in the track reconstruction chain. In the present work a parameterization-based track reconstruction method is described. It is a variation of track following, where the results of the computation-heavy steps, namely the propagation of a track to the further detector plane, and the fitting, are pre-calculated, and expressed in terms of parametric analytic functions. This makes the algorithm extremely fast, and well-suited for an implementation on an FPGA. The method also takes implicitly into account the actual phase space distribution of the tracks already at the stage of candidate construction. Compared to a simple algorithm, that does not use such information, this allows reducing the combinatorial background by many orders of magnitude, down to O(1) background candidate per one signal track. The method is developed specifically for the P2 experiment in Mainz, and the presented implementation is tightly coupled to the experimental conditions.

  6. A study of television imaging system for fast neutron radiography

    International Nuclear Information System (INIS)

    Yoshii, Koji

    1992-01-01

    The neutron radiography with fast neutron beam is a very useful imaging technique for thicker objects, especially those composed of hydrogen-rich materials which are sometimes difficult to image by thermal neutron radiography. The fast neutron radiography has not been studied so much as the thermal neutron radiography. The fast neutron radiography has been studied at the fast neutron source reactor 'Yayoi' of the University of Tokyo built in Tokai-mura. The average neutron energy of the Yayoi is about 1 MeV, and the peak neutron flux at the core center is 0.8 x 10 12 at the maximum operating power of 2 kW. In the experiment on fast neutron radiography, a CR39 nuclear track detector has been used successfully. But in the Yayoi radiography procedure, about 24 hours were required for obtaining an imaging result. To get a prompt imaging result and a real-time imaging result, it is necessary to develop a fast neutron television system, and in this paper, a new fast neutron TV system is proposed. The main difference is the converter material sensitive to fast neutrons. The study on the fast neutron TV system was carried out by using the Baby Cyclotron of Japan Steel Works, and the good images were realized. (K.I.)

  7. Auger processes in tracks of fast multicharged ions

    International Nuclear Information System (INIS)

    Katin, V.V.; Martynenko, Yu.V.; Yavlinskij, Yu.N.

    1992-01-01

    The fast multicharged ion spends about 40% of energy losses on vacancy creation in the inner electron shells. This energy is transferred to the kinetic energy of electrons due to the cascade of Auger processes during ∼ 10 -14 s whereas the primary excited electrons receive the energy in ∼10 -16 s. (author)

  8. Track reconstruction in the emulsion-lead target of the OPERA experiment using the ESS microscope

    Science.gov (United States)

    Arrabito, L.; Bozza, C.; Buontempo, S.; Consiglio, L.; Cozzi, M.; D'Ambrosio, N.; DeLellis, G.; DeSerio, M.; Di Capua, F.; Di Ferdinando, D.; Di Marco, N.; Ereditato, A.; Esposito, L. S.; Fini, R. A.; Giacomelli, G.; Giorgini, M.; Grella, G.; Ieva, M.; Janicsko Csathy, J.; Juget, F.; Kreslo, I.; Laktineh, I.; Manai, K.; Mandrioli, G.; Marotta, A.; Migliozzi, P.; Monacelli, P.; Moser, U.; Muciaccia, M. T.; Pastore, A.; Patrizii, L.; Petukhov, Y.; Pistillo, C.; Pozzato, M.; Romano, G.; Rosa, G.; Russo, A.; Savvinov, N.; Schembri, A.; Scotto Lavina, L.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Strolin, P.; Tioukov, V.; Waelchli, T.

    2007-05-01

    The OPERA experiment, designed to conclusively prove the existence of νμ→ντ oscillations in the atmospheric sector, makes use of a massive lead-nuclear emulsion target to observe the appearance of ντ's in the CNGS νμ beam. The location and analysis of the neutrino interactions in quasi real-time required the development of fast computer-controlled microscopes able to reconstruct particle tracks with sub-micron precision and high efficiency at a speed of ~20 cm2/h. This paper describes the performance in particle track reconstruction of the European Scanning System, a novel automatic microscope for the measurement of emulsion films developed for OPERA.

  9. Track reconstruction in the emulsion-lead target of the OPERA experiment using the ESS microscope

    International Nuclear Information System (INIS)

    Arrabito, L; Bozza, C; Buontempo, S

    2007-01-01

    The OPERA experiment, designed to conclusively prove the existence of ν μ →ν τ oscillations in the atmospheric sector, makes use of a massive lead-nuclear emulsion target to observe the appearance of ν τ 's in the CNGS ν μ beam. The location and analysis of the neutrino interactions in quasi real-time required the development of fast computer-controlled microscopes able to reconstruct particle tracks with sub-micron precision and high efficiency at a speed of ∼20 cm 2 /h. This paper describes the performance in particle track reconstruction of the European Scanning System, a novel automatic microscope for the measurement of emulsion films developed for OPERA

  10. Method of plastic track detector electrochemical etching

    International Nuclear Information System (INIS)

    D'yakov, A.A.

    1984-01-01

    The review of studies dealing with the development of the method for the electro-chemical etching (ECE) of the plastic track detectors on the base of polyethy-leneterephthalate (PET) and polycarbonate (PC) is given. Physical essence of the method, basic parameters of the processes, applied equipment and methods of measurement automation are considered. The advantages of the method over the traditional chemical etching are pointed out. Recommendations on the detector operation modes when detecting fission fragments, α-particles and fast neutrons are given. The ECE method is based on the condition that during chemical etching the high-voltage sound frequency alternating electric field is applied to the detector. In this case the detector serves as an isolating layer betWeen two vessels with etching solution in which high-voltage electrode are submerged. At a fixed electric field potential higher (over than the threshold value) at the end of the etching track cone atree-like discharge spot arises. It is shown that when PET is used for fast neutron detection it is advisable to apply for ECE the PEW solution (15g KOH+40 g C 2 H 2 OH + 45g H 2 O) the field potential should constitute 30 kVxcm -1 at the freqUency of 9 kHz. In the case of fission fragment detection Using ECE and PC the following ECE conditions are recommended: 30% KOH etcher, field potential of 10 kVxcm -1 , 2-4 kHz frequency. It is concluded that the ECE method permits considerably eXtend the sphere of plastic track detector application for detecting ionizing particles,

  11. On the development of inexpensive speed and position tracking system for swimming

    DEFF Research Database (Denmark)

    Trangbæk, Søren; Rasmussen, Cuno; Andersen, Thomas Bull

    2016-01-01

    A semi-automated tracking system was developed for the analysis of swimming, using cameras, an LED diode marker, and a red swim cap. Four experienced young swimmers were equipped with a marker and a swim cap and their position and speed was tracked throughout above-water and under-water swimming...

  12. Development of fast pulsed power driver for radiography and Z-pinch

    International Nuclear Information System (INIS)

    Qiu Aici; Sun Fengju

    2008-01-01

    Z-pinch and flash X-ray radiography have an important application in inertial confine fusion (ICF) and nuclear radiation effects simulation and high performance hydrodynamic test, etc. Z-pinch ICF and multi-pulse multi-axis high energy X-ray radiography put forward a huge challenge for pulsed power driver, so the direct-driven-load fast pulsed power driver are developed actively in home and abroard. The paper summarized the recent advances and developing trends of the fast pulsed power driver based on fast Marx(FMG) and fast linear transformer driver (LTD), and analysized the advantages and disadvantages and restricting factors about FMG and FLTD and their key technologies, then introduced the state-of-arts on the investigation in Northwest Institute of Nuclear Technology. In the end, the paper presented some advices and views about studying fast pulsed power driver applied to Z-pinch and flash X-ray radiography in home. (authors)

  13. Use of cellulose nitrate plastic track detectors in neutron personnel monitoring

    International Nuclear Information System (INIS)

    Venkataraman, G.; Marathe, P.K.; Joshi, R.V.

    1975-01-01

    Cellulose nitrate, which is a sensitive plastic material wherein even proton tracks could be recorded, was studied with a view to using it for personnel neutron monitoring work. It was found that among the commercially available plastics, the colourless transparent Daicel 6000 variety having a thickness of 0.6mm is satisfactory form the point of view of track recognition. The material was exposed to thermal neutrons, fission neutrons, neutrons from an Am-Be source and to 14 MeV neutrons. As is to be expected, there is no thermal neutron sensitivity. The sensitivity to fast neutrons is less by a factor of two as compared to that of the NTA nuclear track emulsion. It was observed that the background tracks found in the plastic correspond to nearly 100 mrem of fast neutron dose equivalent. It is felt that at present cellulose nitrate is useful for monitoring personnel involved in nuclear criticality accidents. (author)

  14. Further development of a track detector as the spectrometer of linear energy transfer

    International Nuclear Information System (INIS)

    Spurny, F.; Bednar, J.; Vlcek, B.; Botollier-Depois, J.F.

    1998-01-01

    Track revealing in a track etch detector is a phenomenon related to the linear energy transfer (LET) of the particle registered. The measurements of track parameters permit to determine the LET corresponding to each revealed track, i.e. LET spectrum. We have recently developed a spectrometer of LET based on the chemically etched polyallyldiglycolcarbonate (PADC). In this contribution the results obtained with such spectrometer in some neutron fields are presented, analyzed and discussed. Several radionuclide neutron sources have been used, LET spectrometer has been also exposed in high energy neutron reference fields at CERN and JINR Dubna, and on board aircraft. (author)

  15. Programme and current status of fast breeder reactor development in Japan

    International Nuclear Information System (INIS)

    Suita, T.; Oyama, A.

    1977-01-01

    In 1967 the Japan Atomic Energy Commission revised her long term programme after a two year study for giving principles to her nuclear energy development programme, which indicated the dominant role of nuclear energy mid 1980's in the electric power generation and stressed the necessity of developing fast breeder reactors. It also recommended to organize a nucleus to undertake this nation-wide project, bringing together the total capability available throughout the country. Accordingly, the Power Reactor and Nuclear Fuel Development Corporation (PNC) was established in 1967 to develop two sodium-cooled fast reactors, an experimental fast reactor of about 100 MW thermal and a prototype fast breeder reactor of about 300 MW electrical, both using mixed oxide fuels. Construction of the experimental fast reactor started in 1970 and was essentially completed at the end of in 1974. The precommissioning test was followed in parallel with re-evaluating quality assurance of all systems. Physics test will be initiated around the end of 1976. The conceptual design of the prototype fast breeder reactor is now toward its final stage. Surveys on its proposed site have just started. Construction will start in 1978. Beside R and D works conducted by many organizations in Japan as well as under the international cooperation, several key test facilities were installed by PNC itself to conduct in-sodium test of full-size prototype components including 50 MW steam generators and post-irradiation-examination of fuels and materials. Recently an interim report was issued to an ad-hoc committee organized by JAEC to evaluate future prospect of the fuel cycle and power reactors. This recommended start of construction of the prototype reactor as scheduled and the large demonstration reactor to be followed to the prototype. Thus the fast breeder reactor is indicated as the most indispensable in 1990's

  16. Automated Measurement of Fast Mitochondrial Transport in Neurons

    Directory of Open Access Journals (Sweden)

    Kyle eMiller

    2015-11-01

    Full Text Available There is a growing recognition that fast mitochondrial transport in neurons is disrupted in multiple neurological diseases and psychiatric disorders. However a major constraint in identifying novel therapeutics based on mitochondrial transport is that the large-scale analysis of fast transport is time consuming. Here we describe methodologies for the automated analysis of fast mitochondrial transport from data acquired using a robotic microscope. We focused on addressing questions of measurement precision, speed, reliably, workflow ease, statistical processing and presentation. We used optical flow and particle tracking algorithms, implemented in ImageJ, to measure mitochondrial movement in primary cultured cortical and hippocampal neurons. With it, we are able to generate complete descriptions of movement profiles in an automated fashion of hundred of thousands of mitochondria with a processing time of approximately one hour. We describe the calibration of the parameters of the tracking algorithms and demonstrate that they are capable of measuring the fast transport of a single mitochondrion. We then show that the methods are capable of reliably measuring the inhibition of fast mitochondria transport induced by the disruption of microtubules with the drug nocodazole in both hippocampal and cortical neurons. This work lays the foundation for future large-scale screens designed to identify compounds that modulate mitochondrial motility.

  17. Trigger and electronics issues for scintillating fiber tracking

    International Nuclear Information System (INIS)

    Baumbaugh, A.E.

    1994-01-01

    Scintillating Fiber technology has made great advances and has demonstrated great promise for high speed charged particle tracking and triggering. The small detector sizes and fast scintillation floors available, make them very promising for use at high luminosity experiments at today's and tomorrow's colliding and fixed target experiments where high rate capability is essential. This paper will discuss some of the system aspects which should be considered by anyone attempting to design a scintillating fiber tracking system and high speed tracking trigger. As the reader will see, seemingly simple decisions can have far reaching effects on overall system performance

  18. The development of fast reactors in France

    International Nuclear Information System (INIS)

    Vautrey, L.

    1982-01-01

    Only minor changes were introduced in the French nuclear programme by the new government in 1981. The operating conditions of Rapsodie were very satisfactory up to January 1982. After a leak in the double primary jacket (nitrogen circuit) the reactor was shut down for investigations. Phenix is continuing to operate smoothly. Construction of Super Phenix (Creys Malville power plant) is proceeding normally though with some delay. The studies for the future (after Creys Malville) are following their way both for the Project 1500 (Super Phenix 2) and for the specific plants of the fuel cycle. Research and development are largely directed toward Super Phenix 1 needs and the prospects of Super Phenix 2. International cooperation remains very intensive. The financial resources devoted to the development of fast reactors are globally stable. Including fuel cycle and safety (but excluding the Phenix operation) about 1300 millions of francs will be devoted to fast reactors by the C.E.A. in 1982. (author)

  19. Development of a tracking method for augmented reality applied to nuclear plant maintenance work

    International Nuclear Information System (INIS)

    Shimoda, Hiroshi; Maeshima, Masayuki; Nakai, Toshinori; Bian, Zhiqiang; Ishii, Hirotake; Yoshikawa, Hidekazu

    2005-01-01

    In this paper, a plant maintenance support method is described, which employs the state-of-the-art information technology, Augmented Reality (AR), in order to improve efficiency of NPP maintenance work and to prevent from human error. Although AR has a great possibility to support various works in real world, it is difficult to apply it to actual work support because the tracking method is the bottleneck for the practical use. In this study, a bar code marker tracking method is proposed to apply AR system for a maintenance work support in NPP field. The proposed method calculates the users position and orientation in real time by two long markers, which are captured by the user-mounted camera. The markers can be easily pasted on the pipes in plant field, and they can be easily recognized in long distance in order to reduce the number of pasted markers in the work field. Experiments were conducted in a laboratory and plant field to evaluate the proposed method. The results show that (1) fast and stable tracking can be realized, (2) position error in camera view is less than 1%, which is almost perfect under the limitation of camera resolution, and (3) it is relatively difficult to catch two markers in one camera view especially in short distance

  20. Studies on neutron detection with solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Khouri, M.C.; Vilela, E.C.; Andrade, C. de.

    1993-03-01

    The detection of thermal and fast neutrons was studied. For thermal neutrons, alpha sensitive plastic was used in order to register the products of nuclear reactions taking place in boron and /or lithium converters. Fast neutrons produce recoil tracks within the detector. In the present case, CR-39 and Makrofol E were used. Chemical and electrochemical etching processes were used for thermal and fast neutron detectors, respectively. (F.E.). 6 refs, 4 figs, 6 tabs

  1. The development of accurate data for the desing of fast reactors

    International Nuclear Information System (INIS)

    Rossouw, P.A.

    1976-04-01

    The proposed use of nuclear power in the generation of electricity in South Africa and the use of fast reactors in the country's nuclear porgram, requires a method for fast reactor evluation. The availability of accurate neutron data and neutronics computation techniques for fast reactors are required for such an evaluation. The reacotr physics and reactor parameters of importance in the evaluation of fast reacotrs are discussed, and computer programs for the computation of reactor spectra and reacotr parameters from differential nuclear data are presented in this treatise. In endeavouring to increase the accuracy in fast reactor design, two methods for the improvement of differential nuclear data were developed and are discussed in detail. The computer programs which were developed for this purpose are also given. The neutron data of the most important fissionable and breeding nuclei (U 235 x U 238 x Pu 239 and Pu 240 ) are adjusted using both methods and the improved neutron data are tested by computation with an advanced neutronics computer program. The improved and orginal neutron data are compared and the use of the improved data in fast reactor design is discussed

  2. MONICA - an on-line track following microprocessor in high energy physics experiments

    International Nuclear Information System (INIS)

    Wermes, N.; Schildt, P.; Stuckenberg, H.J.

    1980-02-01

    In the storage ring experiments at the PETRA accelerator, large cylindrical detectors with thousands of channels are used. The maximum event rate is 500 000 per second, i.e. effective preprocessing is required. In the TASSO detector this is achieved in two steps: A fast trigger system is able to make within 1 microsecond a decision, whether it is a useful event or not. A positive decision starts an on-line track-following ECL computer together with fast associative memories and table look-up. It is a microprogrammed on-line track analyzer called MONICA, which follows up to 10 tracks within 1 millisecond and calculates the coordinates in the R,phi-plane. CAMAC equipment is used for the input of raw data and the output of the calculated track coordinates, speed of the system is ensured by the computer. An outline of the algorithm used and the features of MONICA are given. As far as we know MONICA is the first running on-line track following free programmable microporcessor used in storage ring experiments. (orig.)

  3. Track measurement in the high multiplicity environment at the CBM Experiment

    International Nuclear Information System (INIS)

    Ghosh, Pradeep

    2014-01-01

    In the Compressed Baryonic Matter (CBM) Experiment at FAIR, the Silicon Tracking System (STS) will perform track reconstruction and momentum determination of the charged particles created in interactions of heavy-ion beams with nuclear targets. The STS will consist of 8 tracking layers located at distances between 30 cm and 100 cm downstream of the target inside the 1 Tm magnetic dipole field. An ultra-low material budget is required to achieve momentum resolution of the order of Δp/p = 1%. Therefore, the front-end electronics is placed outside the physics aperture. The active volume of the STS is built from 300 μm thick double-sided silicon microstrip sensors mounted onto lightweight carbon fiber support ladders. The sensors will be read out through ultra-thin micro-cables with fast self-triggering electronics at the periphery of the stations where also other infrastructure such as cooling can be placed. In this paper, the development status of the detector system, highlighting the overview of the STS layout, tracking algorithm and performance simulations are presented.

  4. The status of fast reactor technology development in China

    International Nuclear Information System (INIS)

    Xu, M.

    2002-01-01

    China, as a developing country with a great number of population and relatively less energy resources, reasonably emphasizes the nuclear energy utilization development. For the long term sustainable energy supply, as for nuclear application the basic strategy of PWR-FBR-Fusion has been settled and envisaged. Due to the economy and experience reasons the nuclear power and technology development with a moderate style are kept in China up to now. In China mainland apart from two NPPs with the total capacity of 2.1 GWe in operation, four NPPs are under construction and two NPPs are planned for the Tenth Five Year Plan (2001-2005). Also another one or two NPPs are still in discussion. It could be foreseen that the total nuclear power capacity will reach 8.5GWe before the year 2005 and 14-15 GWe before 2010 respectively. As the first step for the Chinese fast reactor engineering development the 65MWt China Experimental Fast Reactor (CEFR) is under construction. The main components of primary, secondary and tertiary circuits and of fuel handling system have been ordered. The reactor building under construction has reached 16.8m above the ground. Forty seven components and shielding doors have been installed. It is planned that the construction of reactor building with about 40,000m2 floor surface will be completed in the end of the year 2002 and envisaged that the first criticality of the CEFR will be in the end of 2005. The second step of the Chinese fast reactor engineering development is a 300MWe Prototype Fast Breeder Reactor which is only under consideration up to now. Some important technical selections have been settled, but its design has not yet started. (author)

  5. The Progress of Fast Reactor Technology Development in China

    International Nuclear Information System (INIS)

    Yang, Hongyi; Xu, Mi

    1994-01-01

    China, as a developing country with a great number of population and relatively less energy resources, reasonably emphasizes the nuclear energy utilization development. For the long term sustainable energy supply, as for nuclear application the basis strategy of PWR-FBR-Fusion has been settled and envisaged. Due to the economy and experience reasons the nuclear power and technology development with a moderate style are kept in China up to now. In China mainland apart from two NPPs with the total capacity of 2.1 GWe in operation, four NPPs are under construction and two NPPs are planned for the Tenth Five Year Plan(2001-2005). Also another one or two NPPs are still in discussion. It could be foreseen that the total nuclear power capacity will reach 8.5GWe before the year 2005 and 14-15 GWe before respectively. As the first step for the Chinese fast reactor engineering development the 65MWt China Experimental Fast Reactor(CEFR) is under construction. The main components of primary, secondary and tertiary circuits and of fuel handling system have been ordered. The reactor building under construction has reached the top namely 57m above the ground. More than one hundred components and shielding doors have been installed. It is planned that the construction of reactor building with about 40,000m 2 floor surface will be completed in the end of the year 2002 and envisaged that the first criticality of the CEFR will be in the end of 2005. The second step of the Chinese fast reactor engineering development is a 300MWe Prototype Fast Breeder Reactor which in only under consideration up to now. Some important technical selections have been settled, but its design has not yet started

  6. A-Track: Detecting Moving Objects in FITS images

    Science.gov (United States)

    Atay, T.; Kaplan, M.; Kilic, Y.; Karapinar, N.

    2017-04-01

    A-Track is a fast, open-source, cross-platform pipeline for detecting moving objects (asteroids and comets) in sequential telescope images in FITS format. The moving objects are detected using a modified line detection algorithm.

  7. The status of fast reactor technology development in China

    International Nuclear Information System (INIS)

    Xu Mi

    2000-01-01

    Considering the future clean energy supply in China, a rather consistent opinion is to develop nuclear power step by step with the contribution from a supplementary one up to an important one. The large scale utilization of nuclear energy obviously determines the interest in fast breeders; China right now already has about 300 GWe total electricity capacity using conventional energy resources. As the first step for fast reactor technology development in the country, the China Experimental Fast Reactor (CEFR) project is still under detail design stage, which is a sodium cooled pool type fast reactor with 65 MW thermal power matched with a turbine-generator of 25 MW. The ordering of the components is continuing. The site is ready and the steel works for the 3 m x 69 m x 82.5 m foundation base of reactor building are being arranged layer by layer. The review to the PSAR by the China National Nuclear Safety Administration (CNNSA) is going to the final stage, if everything goes smoothly. The first pouring of the concrete for the reactor building will be in the middle of the year 2000. The brief introduction of the CEFR design, safety characteristics, the main results of the safety analysis and design test demonstration are given in the paper. (author)

  8. A highly parallel algorithm for track finding

    International Nuclear Information System (INIS)

    Dell'Orso, M.

    1990-01-01

    We describe a very fast algorithm for track finding, which is applicable to a whole class of detectors like drift chambers, silicon microstrip detectors, etc. The algorithm uses a pattern bank stored in a large memory and organized into a tree structure. (orig.)

  9. Predator-prey interactions in selected slow and fast developing females of a ladybird, Propylea dissecta.

    Science.gov (United States)

    Siddiqui, Arshi; Omkar; Mishra, Geetanjali

    2015-10-14

    Development rate polymorphism describes the scenario in which individuals exhibit distinct differences in their rate of development resulting in slow and fast developers even from the same clutch of eggs. Previously we showed that in ladybird, Propylea dissecta fast developers have higher foraging and predation rates than slow developers. But correlation between foraging efficacies with reproductive output of female remains unexplored. We selected slow and fast developmental rate for 15 generations in a P. dissecta and assessed female functional response and numerical response by using varying prey biomasses (A. pisum). We evaluated predatory parameters: prey consumption, attack rate, handling time, and the reproductive measures: number of eggs laid, egg, and body biomass conversion efficiencies. Overall, both group of P. dissecta showed increased prey biomasses curvilinear for consumption rate demonstrating the physiological capacity of foraging for food are mutually exclusive behaviors (i.e., Holling's Type-II functional response). Consumption rate and proportion of prey consumed was higher, and prey handling time was shorter, in experimental fast developers. However, prey attack rate was higher in experimental slow developers. The functional response of experimental fast developers got elevated whereas got depressed for control slow-fast developers. Our results suggest that slow developers may perform better at low prey biomass than fast developers due to their high attack rate whereas high density prey may favour fast developers due to their shorter prey handling time and higher consumption rates. This study is first attempt to evaluate predatory responses of experimentally selected lines of slow and fast developers. J. Exp. Zool. 9999A:XX-XX, 2015. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  10. Development of an advanced code system for fast-reactor transient analysis

    International Nuclear Information System (INIS)

    Konstantin Mikityuk; Sandro Pelloni; Paul Coddington

    2005-01-01

    FAST (Fast-spectrum Advanced Systems for power production and resource management) is a recently approved PSI activity in the area of fast spectrum core and safety analysis with emphasis on generic developments and Generation IV systems. In frames of the FAST project we will study both statics and transients core physics, reactor system behaviour and safety; related international experiments. The main current goal of the project is to develop unique analytical and code capability for core and safety analysis of critical (and sub-critical) fast spectrum systems with an initial emphasis on a gas cooled fast reactors. A structure of the code system is shown on Fig. 1. The main components of the FAST code system are 1) ERANOS code for preparation of basic x-sections and their partial derivatives; 2) PARCS transient nodal-method multi-group neutron diffusion code for simulation of spatial (3D) neutron kinetics in hexagonal and square geometries; 3) TRAC/AAA code for system thermal hydraulics; 4) FRED transient model for fuel thermal-mechanical behaviour; 5) PVM system as an interface between separate parts of the code system. The paper presents a structure of the code system (Fig. 1), organization of interfaces and data exchanges between main parts of the code system, examples of verification and application of separate codes and the system as a whole. (authors)

  11. Initial Report of the Fast Timing Working Group

    CERN Document Server

    CMS Collaboration

    2016-01-01

    A preliminary set of results highlighting the unique capabilities of fast-timing for resolving information from individual collisions at the High-Luminosity LHC (HL- LHC) is presented. These results explore the possibilities made available by using fast timing to enhance the reconstruction and physics capabilities of the CMS detector in terms of pileup mitigation and searches for new physics. Fast timing applications in calorimetry, for electromagnetic showers, and for MIPs, to time-tag tracks, are demonstrated as are first examples of what is possible with their combination.

  12. Track recognition with an associative pattern memory

    International Nuclear Information System (INIS)

    Bok, H.W. den; Visschers, J.L.; Borgers, A.J.; Lourens, W.

    1991-01-01

    Using Programmable Gate Arrays (PGAs), a prototype for a fast Associative Pattern Memory module has been realized. The associative memory performs the recognition of tracks within the hadron detector data acquisition system at NIKHEF-K. The memory matches the detector state with a set of 24 predefined tracks to identify the particle tracks that occur during an event. This information enables the trigger hardware to classify and select or discriminate the event. Mounted on a standard size (6U) VME board, several PGAs together form an associative memory. The internal logic architecture of the Gate Array is used in such a way as to minimize signal propagation delay. The memory cells, containing a binary representation of the particle tracks, are dynamically loadable through a VME bus interface, providing a high level of flexibility. The hadron detector and its readout system are briefly described and our track representation method is presented. Results from measurements under experimental conditions are discussed. (orig.)

  13. Three-dimensional particle tracking velocimetry using dynamic vision sensors

    Science.gov (United States)

    Borer, D.; Delbruck, T.; Rösgen, T.

    2017-12-01

    A fast-flow visualization method is presented based on tracking neutrally buoyant soap bubbles with a set of neuromorphic cameras. The "dynamic vision sensors" register only the changes in brightness with very low latency, capturing fast processes at a low data rate. The data consist of a stream of asynchronous events, each encoding the corresponding pixel position, the time instant of the event and the sign of the change in logarithmic intensity. The work uses three such synchronized cameras to perform 3D particle tracking in a medium sized wind tunnel. The data analysis relies on Kalman filters to associate the asynchronous events with individual tracers and to reconstruct the three-dimensional path and velocity based on calibrated sensor information.

  14. The Measurement of cloud velocity using the pulsed laser and image tracking technique

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Seong-Ouk; Baik, Seung-Hoon; Park, Seung-Kyu; Park, Nak-Gyu; Kim, Dong-lyul; Ahn, Yong-Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    The height of the clouds is also important for the three dimensional radiative interaction of aerosols and clouds, since the radiative effects vary strongly depending whether the cloud is above, below or even embedded in an aerosol layer. Clouds play an important role in climate change, in the prediction of local weather, and also in aviation safety when instrument assisted flying is unavailable. Presently, various ground-based instruments used for the measurements of the cloud base height or velocity. Lidar techniques are powerful and have many applications in climate studies, including the clouds' temperature measurement, the aerosol particle properties, etc. Otherwise, it is very circumscribed in cloud velocity measurements In this paper, we propose a new method to measure the cloud velocity. In this paper, we presented a method for the measurement of the cloud altitude and velocity using lidar's range detection and the tracking system. For the lidar system, we used an injection-seeded pulsed Nd:YAG laser as the transmitter to measure the distance to the target clouds. We used the DIC system to track the cloud image and calculate the actual displacement per unit time. The configured lidar system acquired the lidar signal of clouds at a distance of about 4 km. The developed fast correlation algorithm of the tracking, which is used to track the fast moving cloud relatively, was efficient for measuring the cloud velocity in real time. The measurement values had a linear distribution.

  15. Astrometry with A-Track Using Gaia DR1 Catalogue

    Science.gov (United States)

    Kılıç, Yücel; Erece, Orhan; Kaplan, Murat

    2018-04-01

    In this work, we built all sky index files from Gaia DR1 catalogue for the high-precision astrometric field solution and the precise WCS coordinates of the moving objects. For this, we used build-astrometry-index program as a part of astrometry.net code suit. Additionally, we added astrometry.net's WCS solution tool to our previously developed software which is a fast and robust pipeline for detecting moving objects such as asteroids and comets in sequential FITS images, called A-Track. Moreover, MPC module was added to A-Track. This module is linked to an asteroid database to name the found objects and prepare the MPC file to report the results. After these innovations, we tested a new version of the A-Track code on photometrical data taken by the SI-1100 CCD with 1-meter telescope at TÜBİTAK National Observatory, Antalya. The pipeline can be used to analyse large data archives or daily sequential data. The code is hosted on GitHub under the GNU GPL v3 license.

  16. Target tracking using DMLC for volumetric modulated arc therapy: A simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Sun Baozhou; Rangaraj, Dharanipathy; Papiez, Lech; Oddiraju, Swetha; Yang Deshan; Li, H. Harold [Department of Radiation Oncology, School of Medicine, Washington University, 4921 Parkview Place, St. Louis, Missouri 63110 (United States); Department of Radiation Oncology, Southwestern Medical Center, University of Texas, Dallas, Texas 75390 (United States); Department of Radiation Oncology, School of Medicine, Washington University, 4921 Parkview Place, St. Louis, Missouri 63110 (United States)

    2010-12-15

    Purpose: Target tracking using dynamic multileaf collimator (DMLC) is a promising approach for intrafraction motion management in radiation therapy. The purpose of this work is to develop a DMLC tracking algorithm capable of delivering volumetric-modulated arc therapy (VMAT) to the targets that experience two-dimensional (2D) rigid motion in the beam's eye view. Methods: The problem of VMAT delivery to moving targets is formulated as a control problem with constraints. The relationships between gantry speed, gantry acceleration, MLC leaf-velocity, dose rate, and target motion are derived. An iterative search algorithm is developed to find numerical solutions for efficient delivery of a specific VMAT plan to the moving target using 2D DMLC tracking. The delivery of five VMAT lung plans is simulated. The planned and delivered fluence maps in the target-reference frame are calculated and compared. Results: The simulation demonstrates that the 2D tracking algorithm is capable of delivering the VMAT plan to a moving target fast and accurately without violating the machine constraints and the integrity of the treatment plan. The average delivery time is only 29 s longer than that of no-tracking delivery, 101 versus 72 s, respectively. The fluence maps are normalized to 200 MU and the average root-mean-square error between the desired and the delivered fluence is 2.1 MU, compared to 14.8 MU for no-tracking and 3.6 MU for one-dimensional tracking. Conclusions: A locally optimal MLC tracking algorithm for VMAT delivery is proposed, aiming at shortest delivery time while maintaining treatment plan invariant. The inconsequential increase of treatment time due to DMLC tracking is clinically desirable, which makes VMAT with DMLC tracking attractive in treating moving tumors.

  17. Tracking Weight Change, Insulin Resistance, Stress, and Aerobic Fitness over 4 Years of College

    Science.gov (United States)

    Hopper, Mari K.; Moninger, Shana Lynn

    2017-01-01

    Objective: To determine if weight gain is accompanied by development of insulin resistance (IR) during 4 years in college. Participants: Two cohorts of college students were enrolled in fall semesters 2009 and 2010 and tracked for 4 years. Methods: Following a 12-hour fast, subjects reported for measurement of body mass index (BMI), perceived…

  18. Fast leaf-fitting with generalized underdose/overdose constraints for real-time MLC tracking

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Douglas, E-mail: douglas.moore@utsouthwestern.edu; Sawant, Amit [Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, Texas 75390 (United States); Ruan, Dan [Department of Radiation Oncology, University of California, Los Angeles, California 90095 (United States)

    2016-01-15

    Purpose: Real-time multileaf collimator (MLC) tracking is a promising approach to the management of intrafractional tumor motion during thoracic and abdominal radiotherapy. MLC tracking is typically performed in two steps: transforming a planned MLC aperture in response to patient motion and refitting the leaves to the newly generated aperture. One of the challenges of this approach is the inability to faithfully reproduce the desired motion-adapted aperture. This work presents an optimization-based framework with which to solve this leaf-fitting problem in real-time. Methods: This optimization framework is designed to facilitate the determination of leaf positions in real-time while accounting for the trade-off between coverage of the PTV and avoidance of organs at risk (OARs). Derived within this framework, an algorithm is presented that can account for general linear transformations of the planned MLC aperture, particularly 3D translations and in-plane rotations. This algorithm, together with algorithms presented in Sawant et al. [“Management of three-dimensional intrafraction motion through real-time DMLC tracking,” Med. Phys. 35, 2050–2061 (2008)] and Ruan and Keall [Presented at the 2011 IEEE Power Engineering and Automation Conference (PEAM) (2011) (unpublished)], was applied to apertures derived from eight lung intensity modulated radiotherapy plans subjected to six-degree-of-freedom motion traces acquired from lung cancer patients using the kilovoltage intrafraction monitoring system developed at the University of Sydney. A quality-of-fit metric was defined, and each algorithm was evaluated in terms of quality-of-fit and computation time. Results: This algorithm is shown to perform leaf-fittings of apertures, each with 80 leaf pairs, in 0.226 ms on average as compared to 0.082 and 64.2 ms for the algorithms of Sawant et al., Ruan, and Keall, respectively. The algorithm shows approximately 12% improvement in quality-of-fit over the Sawant et al

  19. Fast leaf-fitting with generalized underdose/overdose constraints for real-time MLC tracking

    International Nuclear Information System (INIS)

    Moore, Douglas; Sawant, Amit; Ruan, Dan

    2016-01-01

    Purpose: Real-time multileaf collimator (MLC) tracking is a promising approach to the management of intrafractional tumor motion during thoracic and abdominal radiotherapy. MLC tracking is typically performed in two steps: transforming a planned MLC aperture in response to patient motion and refitting the leaves to the newly generated aperture. One of the challenges of this approach is the inability to faithfully reproduce the desired motion-adapted aperture. This work presents an optimization-based framework with which to solve this leaf-fitting problem in real-time. Methods: This optimization framework is designed to facilitate the determination of leaf positions in real-time while accounting for the trade-off between coverage of the PTV and avoidance of organs at risk (OARs). Derived within this framework, an algorithm is presented that can account for general linear transformations of the planned MLC aperture, particularly 3D translations and in-plane rotations. This algorithm, together with algorithms presented in Sawant et al. [“Management of three-dimensional intrafraction motion through real-time DMLC tracking,” Med. Phys. 35, 2050–2061 (2008)] and Ruan and Keall [Presented at the 2011 IEEE Power Engineering and Automation Conference (PEAM) (2011) (unpublished)], was applied to apertures derived from eight lung intensity modulated radiotherapy plans subjected to six-degree-of-freedom motion traces acquired from lung cancer patients using the kilovoltage intrafraction monitoring system developed at the University of Sydney. A quality-of-fit metric was defined, and each algorithm was evaluated in terms of quality-of-fit and computation time. Results: This algorithm is shown to perform leaf-fittings of apertures, each with 80 leaf pairs, in 0.226 ms on average as compared to 0.082 and 64.2 ms for the algorithms of Sawant et al., Ruan, and Keall, respectively. The algorithm shows approximately 12% improvement in quality-of-fit over the Sawant et al

  20. The Siegen automatic measuring system for track detectors: new developments

    International Nuclear Information System (INIS)

    Rusch, G.; Winkel, E.; Noll, A.; Heinrich, W.

    1991-01-01

    Starting twelve years ago we have developed completely automatic scanning and measuring systems for nuclear track detectors. The hardware and software of these systems have continuously been improved. They were used in different heavy ion and cosmic ray experiments. In this paper we describe methods for high resolution REL measurements in plastic nuclear track detectors and methods to scan and measure nuclear disintegration stars in AgCl detectors using an automatic measuring technique. The system uses a stepping motor driven microscope stage, a video camera and an image analysis computer based on a MC68020 microprocessor. (author)

  1. Assessment of the high temperature fission chamber technology for the French fast reactor program

    Energy Technology Data Exchange (ETDEWEB)

    Jammes, C.; Filliatre, P.; Geslot, B.; Domenech, T.; Normand, S. [Commissariat a l' Energie Atomique, CEA (France)

    2011-07-01

    High temperature fission chambers are key instruments for the control and protection of the sodium-cooled fast reactor. First, the developments of those neutron detectors, which are carried out either in France or abroad are reviewed. Second, the French realizations are assessed with the use of the technology readiness levels in order to identify tracks of improvement. (authors)

  2. IMPLEMENTATION OF IMAGE PROCESSING ALGORITHMS AND GLVQ TO TRACK AN OBJECT USING AR.DRONE CAMERA

    Directory of Open Access Journals (Sweden)

    Muhammad Nanda Kurniawan

    2014-08-01

    Full Text Available Abstract In this research, Parrot AR.Drone as an Unmanned Aerial Vehicle (UAV was used to track an object from above. Development of this system utilized some functions from OpenCV library and Robot Operating System (ROS. Techniques that were implemented in the system are image processing al-gorithm (Centroid-Contour Distance (CCD, feature extraction algorithm (Principal Component Analysis (PCA and an artificial neural network algorithm (Generalized Learning Vector Quantization (GLVQ. The final result of this research is a program for AR.Drone to track a moving object on the floor in fast response time that is under 1 second.

  3. Developing the fuzzy c-means clustering algorithm based on maximum entropy for multitarget tracking in a cluttered environment

    Science.gov (United States)

    Chen, Xiao; Li, Yaan; Yu, Jing; Li, Yuxing

    2018-01-01

    For fast and more effective implementation of tracking multiple targets in a cluttered environment, we propose a multiple targets tracking (MTT) algorithm called maximum entropy fuzzy c-means clustering joint probabilistic data association that combines fuzzy c-means clustering and the joint probabilistic data association (PDA) algorithm. The algorithm uses the membership value to express the probability of the target originating from measurement. The membership value is obtained through fuzzy c-means clustering objective function optimized by the maximum entropy principle. When considering the effect of the public measurement, we use a correction factor to adjust the association probability matrix to estimate the state of the target. As this algorithm avoids confirmation matrix splitting, it can solve the high computational load problem of the joint PDA algorithm. The results of simulations and analysis conducted for tracking neighbor parallel targets and cross targets in a different density cluttered environment show that the proposed algorithm can realize MTT quickly and efficiently in a cluttered environment. Further, the performance of the proposed algorithm remains constant with increasing process noise variance. The proposed algorithm has the advantages of efficiency and low computational load, which can ensure optimum performance when tracking multiple targets in a dense cluttered environment.

  4. Development of pulsed high current drivers for fast Z-pinch

    International Nuclear Information System (INIS)

    Sun Fengju; Qiu Aici; Zeng Zhengzhong; Zeng Jiangtao; Kuai Bin; Yang Hailiang

    2006-01-01

    It is required that the peak current of high power pulsed drive for fast Z-pinch reaches 60 MA to realize inertial confine fusion (ICF) and high yield (HY). With the conventional technological methods similar to the Z or Saturn apparatus, increasing driver current further is impractical and difficult according to the cost, structure complexity and reliability of the driver, so it is necessary to develop novel fast pulsed high current driver. The present art-of-state and trends of fast Z-pinch driver are summarized, and the typical conceptual designs and technological methods on ICF/HY PRS (plasma radiation source) and destroying-level super X-ray simulators in USA and Russia are outlined, such as HCEI's UGXX1 driver and new Saturn driver based on fast linear transformer driver (FLTD) and novel driver based on fast Marx generator (FMG) with current of 15 MA. The crucial technological problems and requirements to investigate in the future are presented. (authors)

  5. Towards Fast Tracking of the Keyhole Geometry

    Science.gov (United States)

    Brock, C.; Hohenstein, R.; Schmidt, M.

    We describe a sensor principle permitting the fast online measurement of the position of the optical process emissions in deep penetration laser welding. Experiments show a strong correlation between the position of the vapour plume and the keyhole geometry, demonstrated here by varying the penetration depth of the weld. In order to achieve an absolute position measurement, the sensor was calibrated using a light source with well defined characteristics. The setup for the calibration measurements and the corresponding data evaluation methods are discussed. The precision of the calibration with a green LED is 6 μm in lateral and 55 μm in axial direction, for a working distance of 200 mm.

  6. Development of the dyed-track method for Kodak CN-85 detector. No. E/3

    International Nuclear Information System (INIS)

    Somogyi, G.; Toth-Szilagyi, M.; Varga, Zs.; Monnin, M.; Lferde, M.

    1983-01-01

    The dyed-track method has been successfully developed for cellulose derivatives. The track parameters (width, coloration deepness, contrast, registration sensitivity), however, proved to be very dependent on the detector material and on the track processing conditions. In the authors' previous works optimum conditions were presented mostly for cellulose acetate sheets. In the present work the influence of track processing parameters on the dyed-track formation was studied in Kodak cellulose nitrate detector called CN-85. It is found that in this material optimum dyed-tracks can be produced with using no swelling but with a thermal annealing at 100 deg C for 1 hour after particles irradiation. For sensitization a treatment with 15% HCL at 22 deg C for 20 hours and for dyeing 0.3 wt% Rhodamine-B at 100 deg C for 1 hour proved to be best. For understanding the track dyeing phenomenon the coloration behaviour of electron-irradiated CN-85 detectors was studied. (author)

  7. MPACT Fast Neutron Multiplicity System Prototype Development

    Energy Technology Data Exchange (ETDEWEB)

    D.L. Chichester; S.A. Pozzi; J.L. Dolan; M.T. Kinlaw; S.J. Thompson; A.C. Kaplan; M. Flaska; A. Enqvist; J.T. Johnson; S.M. Watson

    2013-09-01

    This document serves as both an FY2103 End-of-Year and End-of-Project report on efforts that resulted in the design of a prototype fast neutron multiplicity counter leveraged upon the findings of previous project efforts. The prototype design includes 32 liquid scintillator detectors with cubic volumes 7.62 cm in dimension configured into 4 stacked rings of 8 detectors. Detector signal collection for the system is handled with a pair of Struck Innovative Systeme 16-channel digitizers controlled by in-house developed software with built-in multiplicity analysis algorithms. Initial testing and familiarization of the currently obtained prototype components is underway, however full prototype construction is required for further optimization. Monte Carlo models of the prototype system were performed to estimate die-away and efficiency values. Analysis of these models resulted in the development of a software package capable of determining the effects of nearest-neighbor rejection methods for elimination of detector cross talk. A parameter study was performed using previously developed analytical methods for the estimation of assay mass variance for use as a figure-of-merit for system performance. A software package was developed to automate these calculations and ensure accuracy. The results of the parameter study show that the prototype fast neutron multiplicity counter design is very nearly optimized under the restraints of the parameter space.

  8. Development of alarm cause tracking system for Korea standard nuclear power plant

    International Nuclear Information System (INIS)

    Lee, Jung Woon; Kim, Jung Taek; Park, Jae Chang; Lee, Hyun Chul; Park, Joong Pal

    2004-05-01

    The proposed system, the ACTS(Alarm Cause Tracking System), in the 1st and 2nd development period(2001. 7 ∼ 2003. 6), tracks and displays the causes of alarms on-line from computerized logic diagrams. And the system highlights the specific procedures related the causes in the procedure of the alarm. In this period(2003. 7 ∼ 2004. 4), we developed the ACTS for Korea standard nuclear power plant. Also, we computerized control logic diagrams and alarm procedures for the ACTS. A long-term target is to apply the ACTS at the real power plant, and a short-term target is to connect the ACTS with the ITF(Intergrated Test Facility) in KAERI site to develop other applications

  9. Tracking reliability for space cabin-borne equipment in development by Crow model.

    Science.gov (United States)

    Chen, J D; Jiao, S J; Sun, H L

    2001-12-01

    Objective. To study and track the reliability growth of manned spaceflight cabin-borne equipment in the course of its development. Method. A new technique of reliability growth estimation and prediction, which is composed of the Crow model and test data conversion (TDC) method was used. Result. The estimation and prediction value of the reliability growth conformed to its expectations. Conclusion. The method could dynamically estimate and predict the reliability of the equipment by making full use of various test information in the course of its development. It offered not only a possibility of tracking the equipment reliability growth, but also the reference for quality control in manned spaceflight cabin-borne equipment design and development process.

  10. A Hardware Fast Tracker for the ATLAS trigger

    CERN Document Server

    Asbah, Nedaa; The ATLAS collaboration

    2015-01-01

    The trigger system of the ATLAS experiment is designed to reduce the event rate from the LHC nominal bunch crossing at 40 MHz to about 1 kHz, at the design luminosity of 10^{34} cm^{-2}s^{-1}. After a successful period of data taking from 2010 to early 2013, the LHC restarted with much higher instantaneous luminosity. This will increase the load on High Level Trigger system, the second stage of the selection based on software algorithms. More sophisticated algorithms will be needed to achieve higher background rejection while maintaining good efficiency for interesting physics signals. The Fast TracKer (FTK) is part of the ATLAS trigger upgrade project; it is a hardware processor that will provide, at every level-1 accepted event (100 kHz) and within 100 microseconds, full tracking information for tracks with momentum as low as 1 GeV. Providing fast extensive access to tracking information, with resolution comparable to the offline reconstruction, FTK will help in precise detection of the primary and secondar...

  11. Present status of fast neutron personnel dosimetry system based on CR-39 solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Pal, Rupali; Sathian, Deepa; Jayalakshmi, V.; Bakshi, A.K.; Chougaonkar, M.P.; Mayya, Y.S.; Kumar, Valli; Babu, Rajesh; Kar, S.; Joshi, V.M.

    2011-08-01

    Neutron sources are of different types depending upon the method of production such as nuclear reactors, particle accelerators and laboratory sources. Neutron sources depending upon their energy, flux, size etc. are used for variety of applications in basic and applied sciences, neutron scattering experiments and in industry such as oil well - digging, coal mining and processing, ore processing etc. Personnel working in nuclear installations such as reactors, accelerators, spent fuel processing plants, nuclear fuel cycle operations and those working in various industries such as oil refining, oil well-digging, coal mining and processing, ore processing, etc. need to be monitored for neutron exposures, if any. Neutron monitoring is especially necessary in view of the fact that the radiation weighting factor for neutron is much higher than gamma rays and also it varies with energy. Radiological Physics and Advisory Division is involved in monitoring of personnel working in neutron fields. Around 2100 workers from 70 institutions (DAE and Non-DAE) are monitored on a quarterly basis. Neutron personnel monitoring, carried out in the country is based on Solid State Nuclear Track Detection (SSNTD) technique. In this technique, neutrons interact with hydrogen in CR-39 polymer to produce recoil protons. These protons create damages in the polymer, which are enlarged and appear as tracks when subjected to electrochemical etching (ECE). These tracks are counted in an optical system to evaluate the neutron dose. The neutron dosimetry system based on SSNTD has undergone a significant development, since it was started in 1990. The development includes upgradation of image analysis system for counting tracks, introduction of chemical etching (CE) at elevated temperatures for evaluation of dose equivalents above 10 mSv and use of carbon laser for cutting of CR-39 detectors. The entire dose evaluation process has been standardized, which includes calibration and performance tests

  12. Cultivating Future Radiology Educators: Development and Implementation of a Clinician-Educator Track for Residents.

    Science.gov (United States)

    Mendoza, Dexter; Peterson, Ryan; Ho, Christopher; Harri, Peter; Baumgarten, Deborah; Mullins, Mark E

    2018-05-03

    Effective and dedicated educators are critical to the preservation and advancement of the practice of radiology. The need for innovative and adaptable educators is increasingly being recognized, with several institutions granting academic promotions through clinician-educator tracks. The implementation of resident "clinician-educator tracks" or "teaching tracks" should better prepare residents aspiring to become academic radiologists focused on teaching. In this work, we describe our experience in the development and implementation of a clinician-educator track for diagnostic radiology residents at our institution. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  13. AUTOMATIC FAST VIDEO OBJECT DETECTION AND TRACKING ON VIDEO SURVEILLANCE SYSTEM

    Directory of Open Access Journals (Sweden)

    V. Arunachalam

    2012-08-01

    Full Text Available This paper describes the advance techniques for object detection and tracking in video. Most visual surveillance systems start with motion detection. Motion detection methods attempt to locate connected regions of pixels that represent the moving objects within the scene; different approaches include frame-to-frame difference, background subtraction and motion analysis. The motion detection can be achieved by Principle Component Analysis (PCA and then separate an objects from background using background subtraction. The detected object can be segmented. Segmentation consists of two schemes: one for spatial segmentation and the other for temporal segmentation. Tracking approach can be done in each frame of detected Object. Pixel label problem can be alleviated by the MAP (Maximum a Posteriori technique.

  14. Development and evaluation of tracking method for augmented reality system for nuclear power plant maintenance support

    International Nuclear Information System (INIS)

    Ishii, Hirotake; Bian, Zhiqiang; Sekiyama, Tomoki; Shimoda, Hiroshi; Yoshikawa, Hidekazu; Izumi, Masanori; Kanehira, Yoshiki; Morishita, Yoshitsugu

    2007-01-01

    This study aims at developing an augmented reality system to support maintenance work of nuclear power plants. An accurate and wide-range tracking method is required as a key technology in order to realize the system. In this study, a new tracking method using multi-camera and gyro sensor has been developed in order to enlarge the area where the tracking is available with limited number of markers. Experimental evaluation result shows that the area where the developed method can cover is about 3 times larger than the method using only single camera. (author)

  15. Development and evaluation of tracking method for augmented reality system for nuclear power plant maintenance support

    International Nuclear Information System (INIS)

    Ishii, Hirotake; Bian, Zhiqiang; Sekiyama, Tomoki; Shimoda, Hiroshi; Yoshikawa, Hidekazu; Izumi, Masanori; Kanehira, Yoshiki; Morishita, Yoshitsugu

    2006-01-01

    This study aims at developing an augmented reality system to support maintenance work of nuclear power plants. An accurate and wide-range tracking method is required as a key technology in order to realize the system. In this study, a new tracking method using multi-camera and gyro sensor has been developed in order to enlarge the area where the tracking is available with limited number of markers. Experimental evaluation result shows that the area where the developed method can cover is about 3 times larger than the method using single camera. (author)

  16. Variation in ‘fast-track’ referrals for suspected cancer by patient characteristic and cancer diagnosis: evidence from 670 000 patients with cancers of 35 different sites

    Science.gov (United States)

    Zhou, Y; Mendonca, S C; Abel, G A; Hamilton, W; Walter, F M; Johnson, S; Shelton, J; Elliss-Brookes, L; McPhail, S; Lyratzopoulos, G

    2018-01-01

    Background: In England, ‘fast-track’ (also known as ‘two-week wait’) general practitioner referrals for suspected cancer in symptomatic patients are used to shorten diagnostic intervals and are supported by clinical guidelines. However, the use of the fast-track pathway may vary for different patient groups. Methods: We examined data from 669 220 patients with 35 cancers diagnosed in 2006–2010 following either fast-track or ‘routine’ primary-to-secondary care referrals using ‘Routes to Diagnosis’ data. We estimated the proportion of fast-track referrals by sociodemographic characteristic and cancer site and used logistic regression to estimate respective crude and adjusted odds ratios. We additionally explored whether sociodemographic associations varied by cancer. Results: There were large variations in the odds of fast-track referral by cancer (P<0.001). Patients with testicular and breast cancer were most likely to have been diagnosed after a fast-track referral (adjusted odds ratios 2.73 and 2.35, respectively, using rectal cancer as reference); whereas patients with brain cancer and leukaemias least likely (adjusted odds ratios 0.05 and 0.09, respectively, for brain cancer and acute myeloid leukaemia). There were sex, age and deprivation differences in the odds of fast-track referral (P<0.013) that varied in their size and direction for patients with different cancers (P<0.001). For example, fast-track referrals were least likely in younger women with endometrial cancer and in older men with testicular cancer. Conclusions: Fast-track referrals are less likely for cancers characterised by nonspecific presenting symptoms and patients belonging to low cancer incidence demographic groups. Interventions beyond clinical guidelines for ‘alarm’ symptoms are needed to improve diagnostic timeliness. PMID:29182609

  17. Development of radiation hardened robot for nuclear facility - Development of real-time stereo object tracking system using the optical correlator

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Soo; Lee, S. H.; Lee, J. S. [Kwangwoon University, Seoul (Korea)

    2000-03-01

    Object tracking, through Centroide method used in the KAERI-M1 Stereo Robot Vision System developed at Atomic Research Center, is too sensitive to target's light variation and because it has a fragility which can't reflect the surrounding background, the application in the actual condition is very limited. Also the correlation method can constitute a relatively stable object tracker in noise features but the digital calculation amount is too massive in image correlation so real time materialization is limited. So the development of Optical Correlation based on Stereo Object Tracking System using high speed optical information processing technique will put stable the real time stereo object tracking system and substantial atomic industrial stereo robot vision system to practical use. This research is about developing real time stereo object tracking algorithm using optical correlation system through the technique which can be applied to Atomic Research Center's KAERI-M1 Stereo Vision Robot which will be used in atomic facility remote operations. And revise the stereo disparity using real time optical correlation technique, and materializing the application of the stereo object tracking algorithm to KAERI-M1 Stereo Robot. 19 refs., 45 figs., 2 tabs. (Author)

  18. Fuzzy Tracking and Control Algorithm for an SSVEP-Based BCI System

    Directory of Open Access Journals (Sweden)

    Yeou-Jiunn Chen

    2016-09-01

    Full Text Available Subjects with amyotrophic lateral sclerosis (ALS consistently experience decreasing quality of life because of this distinctive disease. Thus, a practical brain-computer interface (BCI application can effectively help subjects with ALS to participate in communication or entertainment. In this study, a fuzzy tracking and control algorithm is proposed for developing a BCI remote control system. To represent the characteristics of the measured electroencephalography (EEG signals after visual stimulation, a fast Fourier transform is applied to extract the EEG features. A self-developed fuzzy tracking algorithm quickly traces the changes of EEG signals. The accuracy and stability of a BCI system can be greatly improved by using a fuzzy control algorithm. Fifteen subjects were asked to attend a performance test of this BCI system. The canonical correlation analysis (CCA was adopted to compare the proposed approach, and the average recognition rates are 96.97% and 94.49% for proposed approach and CCA, respectively. The experimental results showed that the proposed approach is preferable to CCA. Overall, the proposed fuzzy tracking and control algorithm applied in the BCI system can profoundly help subjects with ALS to control air swimmer drone vehicles for entertainment purposes.

  19. Trends and Developments for Fast Neutron Reactors and Related Fuel Cycles

    International Nuclear Information System (INIS)

    Carré, Frank

    2013-01-01

    • FR13 – A unique and dedicated framework to share updates on national programs of Fast Reactor developments, projects of new builds and plans for the future: - Near term projects of sodium and lead-alloy Fast Reactors; - Gen-IV visions of sodium-cooled and alternative types of Fast Neutron Reactors (GFR, LFR…). • FR13 – A special emphasis put on Fast Reactor Safety, Sustainability of nuclear fuel cycle and Young Generation perspective. • FR13 – A catalyst for further collaborations and alliances: - To share visions of goals and advisable options for future Fast Reactors and Nuclear Fuel Cycle; - To share cost of R&D and large demonstrations (safety, security, recycling); - To progress towards harmonized international standards; - To integrate national projects into a consistent international roadmap

  20. Recent developments for fast reactor structural design standard (FDS)

    International Nuclear Information System (INIS)

    Kasahara, N.; Nakamuria, K.; Morishita, M.; Shibamoto, H.; Nagashima, H.; Inoue, K.

    2005-01-01

    For realization of reliable and economical fast reactor (FR) plants, Japan Nuclear Cycle Development Institute(JNC) and Japan Atomic Power Company(JAPC) are cooperating on 'Feasibility Study on Commercialized FR Cycle Systems'. To certify the design concepts through evaluation of their structural integrity, the research and development of 'Elevated Temperature Structural Design Guide for Commercialized Fast Reactor (FDS)' is recognized as an essential theme. FDS focuses on particular failure modes of FRs such as ratchet deformation and creep fatigue damages due to cyclic thermal loads. To evaluate these modes, three main developments are in progress. One is 'Refinement of Failure Criteria' for particular modes of FRs. Next is development of 'Guidelines for Inelastic Design Analysis' in order to predict elastic plastic and creep behaviors. Furthermore, efforts are being made toward preparing 'Guidelines for Thermal Load Modeling' for FR component design where thermal loads are dominant. These studies were performed under the sponsorship of the Ministry of Economy, Trade and Industry of Japanese government. (authors)