WorldWideScience

Sample records for fast spgr single

  1. Comparison of MRI fast SPGR single slice scan and continuous dynamic scan in patients with obstructive sleep apnea-hypopnea syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Xinyu [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: myginny2@sina.com; Yang Xue [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: yangxueqyfy@126.com; Hua Hui [Department of Otorhinolaryngology-Head and Neck Surgery, Medical School Hospital of Qingdao University, Qingdao (China)], E-mail: huahuisky@163.com; Chen Jingjing [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: chenjingjingsky@126.com

    2009-07-15

    Objective: To evaluate the application value of MRI fast SPGR single slice scan in patients with obstructive sleep apnea-hypopnea syndrome when comparing the images between fast SPGR single slice scan and continuous dynamic scan. Methods: Eighteen patients with obstructive sleep apnea-hypopnea syndrome were examined by fast SPGR single slice scan and continuous dynamic scan in turn. Fast SPGR single slice scans were conducted when the phases of apnea, inspiration and expiration appeared on the respiratory wave of the subjects. Fast SPGR continuous dynamic scans were conducted when the patients were awake and apneic. The scan planes were median sagittal plane and axial planes (the slice of middle part of palate, the slice of inferior part of palate, the slice of middle part of lingual root and the slice of 0.5 cm beneath the free margin of epiglottis). The obstructed sites and the cross-sectional areas of upper airway were compared between the two scan methods. Results: Seven cases showed complete obstruction at the narrowest sites of upper airway when apnea appeared; eleven cases showed marked decrease in cross-sectional areas at the narrowest sites compared with the areas when the patients were awake; two cases manifested multiple narrowness. The obstructed sites showed by the two scan methods were same. The difference of the cross-sectional areas of upper airway between the two scan methods was insignificant (P > 0.05). Conclusion: Fast SPGR single slice scan can accurately reflect the obstructed sites of upper airway when the breath breaks off and is the complementary method of continuous dynamic scan. Sometimes, single slice scan can replace continuous dynamic scan.

  2. Fat-suppressed three-dimensional fast spoiled gradient-recalled echo imaging: a modified FS 3D SPGR technique for assessment of patellofemoral joint chondromalacia.

    Science.gov (United States)

    Wang, S F; Cheng, H C; Chang, C Y

    1999-01-01

    Fast fat-suppressed (FS) three-dimensional (3D) spoiled gradient-recalled echo (SPGR) imaging of 64 articular cartilage regions in 16 patellofemoral joints was evaluated to assess its feasibility in diagnosing patellofemoral chondromalacia. It demonstrated good correlation with arthroscopic reports and took about half of the examination time that FS 3D SPGR did. This modified, faster technique has the potential to diagnose patellofemoral chondromalacia with shorter examination time than FS 3D SPGR did.

  3. Clinical evaluation of fat suppressed fast-SPGR sequence of the breast MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Mitsuyuki; Hasegawa, Makoto; Matsubara, Tadashi [Yokohama Sakae Kyosai Hospital (Japan)

    1998-05-01

    MR-mammography by fat suppressed Fast-SPGR was evaluated for diagnosis and determination of invasion of tumor. Dynamic MRIs were performed in 12 phases, such as, before infusion of contrast media, right after and one to ten minutes after infusion with interval of one minute. In 15 patients (breast cancer, fibroadenoma, lymphocytic lobulitits and cystic intraductal papilloma), underwent MRI, the images were compared with pathological findings. Ten cases were confirmed as malignancy among 11 cases of breast cancer (sensitivity 91%). Eleven cases were confirmed as breast cancer among 12 cases diagnosed as breast cancer by MRI (specificity 92%). In 12 of all 15 cases, benignity or malignancy was checked correctly (accuracy 80%). Invasion of breast cancer was defined as the deep color dyeing area which was neighbored with the tumor in early stage of cystography. Eight of 11 cases were diagnosed precisely with fat suppression image, and nine were by subtraction image. Diagnosis was possible only by subtraction image in a case of scirrhous carcinoma accompanied with intradutal invasion. The area of invasion was not defined correctly in the case accompanied by mastopathy. It is difficult to evaluate benignity or malignancy of mammary gland tumor only by dynamic MRI, it is necessary to diagnose the shape and deep color image of tumor generally. (K.H.)

  4. Usefulness of IDEAL T2-weighted FSE and SPGR imaging in reducing metallic artifacts in the postoperative ankles with metallic hardware

    International Nuclear Information System (INIS)

    Lee, Jung Bin; Cha, Jang Gyu; Lee, Min Hee; Lee, Eun Hye; Lee, Young Koo; Jeon, Chan Hong

    2013-01-01

    The aim of this work is to prospectively compare the effectiveness of iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL), T2-weighted fast spin-echo (FSE), and spoiled gradient-echo (SPGR) MR imaging to frequency selective fat suppression (FSFS) protocols for minimizing metallic artifacts in postoperative ankles with metallic hardware. The T2-weighted and SPGR imaging with IDEAL and FSFS were performed on 21 ankles of 21 patients with metallic hardware. Two musculoskeletal radiologists independently analyzed techniques for visualization of ankle ligaments and articular cartilage, uniformity of fat saturation, and relative size of the metallic artifacts. A paired t test was used for statistical comparisons of MR images between IDEAL and FSFS groups. IDEAL T2-weighted FSE and SPGR images enabled significantly improved visualization of articular cartilage (p < 0.05), the size of metallic artifact (p < 0.05), and the uniformity of fat saturation (p < 0.05). However, no significant improvement was found in the visibility of ligaments. IDEAL T2-weighted FSE and SPGR imaging effectively reduces the degree of tissue-obscuring artifacts produced by fixation hardware in ankle joints and improves image quality compared to FSFS T2-weighted FSE and SPGR imaging. However, visibility of ligaments was not improved using IDEAL imaging. (orig.)

  5. MR imaging of the early rheumatoid arthritis: usefulness of contrast enhanced fat suppressed SPGR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Mi; Joo, Kyung Bin; Kim, Seong Tae; Hahm, Chang Kok [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1995-06-15

    To evaluate value of post-contrast 3-Dimensional fat suppressed Spoiled GRASS (FS SPGR) in detecting subtle bony erosion and tenosynovitis of hands and wrists due to early rheumatoid arthritis. Fourteen MR imagings of the hands and wrists were performed in 7 early rheumatoid arthritis without any abnormalities in plain radiography and in 7 healthy volunteers. All subjects underwent MR sequence of coronal 3D FS SPGR with and without contrast enhancement in 1.5T MR unit. We evaluated the number of the bony erosion and tenosynovitis respectively in pre-and post-contrast FS SPGR images. The abnormal enhancing areas were not demonstrated in 7 healthy volunteers. Seven patients had 25 bony erosions in pre-contrast FS SPGR and 52 bony erosions with tenosynovitis (n = 10) in post-contrast FS SPGR. Enhancing joint spaces were shown in 8 cases. Post-contrast FS SPGR was better than pre-contrast FS SPGR in the evaluation of early rheumatoid arthritis and is valuable as a baseline study.

  6. MR imaging of the early rheumatoid arthritis: usefulness of contrast enhanced fat suppressed SPGR imaging

    International Nuclear Information System (INIS)

    Kim, Sun Mi; Joo, Kyung Bin; Kim, Seong Tae; Hahm, Chang Kok

    1995-01-01

    To evaluate value of post-contrast 3-Dimensional fat suppressed Spoiled GRASS (FS SPGR) in detecting subtle bony erosion and tenosynovitis of hands and wrists due to early rheumatoid arthritis. Fourteen MR imagings of the hands and wrists were performed in 7 early rheumatoid arthritis without any abnormalities in plain radiography and in 7 healthy volunteers. All subjects underwent MR sequence of coronal 3D FS SPGR with and without contrast enhancement in 1.5T MR unit. We evaluated the number of the bony erosion and tenosynovitis respectively in pre-and post-contrast FS SPGR images. The abnormal enhancing areas were not demonstrated in 7 healthy volunteers. Seven patients had 25 bony erosions in pre-contrast FS SPGR and 52 bony erosions with tenosynovitis (n = 10) in post-contrast FS SPGR. Enhancing joint spaces were shown in 8 cases. Post-contrast FS SPGR was better than pre-contrast FS SPGR in the evaluation of early rheumatoid arthritis and is valuable as a baseline study

  7. Prospective comparison of 3D FIESTA versus fat-suppressed 3D SPGR MRI in evaluating knee cartilage lesions

    International Nuclear Information System (INIS)

    Li, X.; Yu, C.; Wu, H.; Daniel, K.; Hu, D.; Xia, L.; Pan, C.; Xu, A.; Hu, J.; Wang, L.; Peng, W.; Li, F.

    2009-01-01

    Aim: To prospectively compare the accuracy of three-dimensional fast imaging employing steady-state acquisition (3D FIESTA) sequences with that of fat-suppressed three-dimensional spoiled gradient-recalled (3D SPGR) in the diagnosis of knee articular cartilage lesions, using arthroscopy as the reference standard. Materials and methods: Fifty-eight knees in 54 patients (age range 21-82 years; mean 36 years) were prospectively evaluated by using sagittal 3D FIESTA and sagittal fat-suppressed 3D SPGR sequences. Articular cartilage lesions were graded on MRI and during arthroscopy with a modified Noyes scoring system. Sensitivity, specificity, and accuracy were assessed. Interobserver agreement was determined with κ statistics. Results: The performance of 3D FIESTA sequences (sensitivity, specificity, and accuracy were 80, 94, and 92%, respectively, for reader 1 and 76, 94, and 90%, respectively, for reader 2) was similar to that of fat-suppressed 3D SPGR sequences (sensitivity, specificity, and accuracy were 82, 92, and 90%, respectively, for reader 1 and 82, 90, and 88%, respectively, for reader 2) in the detection of knee articular cartilage lesions. The interobserver agreement varied from fair to good to excellent (kappa values from 0.43-0.83). Conclusion: 3D FIESTA has good diagnostic performance, comparable with fat-suppressed 3D SPGR in evaluating knee cartilage lesions, and it can be incorporated into routine knee MRI protocols due to the short acquisition time.

  8. Prospective comparison of 3D FIESTA versus fat-suppressed 3D SPGR MRI in evaluating knee cartilage lesions

    Energy Technology Data Exchange (ETDEWEB)

    Li, X.; Yu, C. [Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030 (China); Wu, H. [Department of Orthopaedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030 (China)], E-mail: lilyboston2002@163.com; Daniel, K. [Department of Radiology, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA 02115 (United States); Hu, D.; Xia, L.; Pan, C.; Xu, A.; Hu, J.; Wang, L.; Peng, W. [Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030 (China); Li, F. [Department of Orthopaedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030 (China)

    2009-10-15

    Aim: To prospectively compare the accuracy of three-dimensional fast imaging employing steady-state acquisition (3D FIESTA) sequences with that of fat-suppressed three-dimensional spoiled gradient-recalled (3D SPGR) in the diagnosis of knee articular cartilage lesions, using arthroscopy as the reference standard. Materials and methods: Fifty-eight knees in 54 patients (age range 21-82 years; mean 36 years) were prospectively evaluated by using sagittal 3D FIESTA and sagittal fat-suppressed 3D SPGR sequences. Articular cartilage lesions were graded on MRI and during arthroscopy with a modified Noyes scoring system. Sensitivity, specificity, and accuracy were assessed. Interobserver agreement was determined with {kappa} statistics. Results: The performance of 3D FIESTA sequences (sensitivity, specificity, and accuracy were 80, 94, and 92%, respectively, for reader 1 and 76, 94, and 90%, respectively, for reader 2) was similar to that of fat-suppressed 3D SPGR sequences (sensitivity, specificity, and accuracy were 82, 92, and 90%, respectively, for reader 1 and 82, 90, and 88%, respectively, for reader 2) in the detection of knee articular cartilage lesions. The interobserver agreement varied from fair to good to excellent (kappa values from 0.43-0.83). Conclusion: 3D FIESTA has good diagnostic performance, comparable with fat-suppressed 3D SPGR in evaluating knee cartilage lesions, and it can be incorporated into routine knee MRI protocols due to the short acquisition time.

  9. Comparison of T1rho imaging between spoiled gradient echo (SPGR) and balanced steady state free precession (b-FFE) sequence of knee cartilage at 3 T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Nozaki, Taiki; Kaneko, Yasuhito; Yu, Hon J. [Department of Radiological Sciences, University of California, Irvine, CA (United States); Kaneshiro, Kayleigh [School of Medicine, University of California, Irvine, CA (United States); Schwarzkopf, Ran [Department of Orthopaedic Surgery, University of California, Irvine, CA (United States); Yoshioka, Hiroshi, E-mail: hiroshi@uci.edu [Department of Radiological Sciences, University of California, Irvine, CA (United States)

    2015-07-15

    Highlights: • T1rho values on b-FFE tend to be higher than those on SPGR. • The reproducibility of T1rho cartilage segmentation is higher on SPGR than b-FFE. • There is angular variation of T1rho profiles. • Average T1rho values in the superficial layer are higher than in the deep layer. - Abstract: Purpose: To investigate the difference in T1rho profiles of the entire femoral cartilage between SPGR and b-FFE sequences at 3.0 T. Materials and methods: 20 healthy volunteers were enrolled in this study. T1rho images of each subject were acquired with two types of pulse sequences: SPGR and b-FFE. Femoral cartilage segmentation was performed by two independent raters slice-by-slice using Matlab. Inter- and intra-observer reproducibility between the two imaging protocols was calculated. The relative signal intensity (SI) of cartilage, subchondral bone marrow, joint effusion, and the relative signal contrast between structures of the knee were quantitatively measured. The difference in T1rho values between SPGR and b-FFE sequences was statistically analyzed using the Wilcoxon signed-rank test. Results: The average T1rho value of the entire femoral cartilage with b-FFE was significantly higher compared to SPGR (p < 0.05). The reproducibility of the segmented area and T1rho values was superior with SPGR compared to b-FFE. The inter-class correlation coefficient was 0.846 on SPGR and 0.824 on b-FFE. The intra-class correlation coefficient of T1rho values was 0.878 on SPGR and 0.836 on b-FFE. The two imaging techniques demonstrated different signal and contrast characteristics. The relative SI of fluid was significantly higher on SPGR, while the relative SI of subchondral bone was significantly higher on b-FFE (p < 0.001). There were also significant differences in the relative contrast between fluid–cartilage, fluid–subchondral bone, and cartilage–subchondral bone between the two sequences (all p < 0.001). Conclusion: We need to pay attention to differences in

  10. Identification of offending vessele in trigeminal neuralgia and hemifacial spasm using SPGR-MRI and 3D-TOF-MRA

    International Nuclear Information System (INIS)

    Niwa, Yoshikazu; Shiotani, Masahiro; Karasawa, Hidetake; Ohseto, Kiyoshige; Naganuma, Yoshikazu

    1996-01-01

    We investigated 100 consecutive patients with trigeminal neuralgia (TN) and 53 patients with hemifacial spasm (HFS) concerning the anatomical relationship between the root entry (exit) zone (REZ) of cranial nerve and the offending artery, using spoiled GRASS MRI (SPGR-MRI) and three dimensional-time of fly-MRA (MRA). In 67 of 100 (67%) patients with TN, this new radiological method, SPGR-MRI and MRA demonstrated the relationship between the fifth cranial nerve root and offending artery causing neurovascular compression (NVC), and in 46 of 53 (87%) with HFS, demonstrated the similar relationship between seventh and eighth nerve complex and offending artery. Microvascular decompression (MVD) was performed in 10 with HFS, and NVC of the REZ of the facial nerve caused by the offending artery was exactly predicted by SPGR-MRI and MRA in 9 (90%). The combination of SPGR-MRI and MRA is very useful for demonstrating NVC as the cause of TN and HFS. On the other hand, we investigated asymptomatic 206 trigemimal and 253 facial nerves about the relationship between their REZ and the surrounding structures using the similar method. The contact of REZ of cranial nerve with surrounding artery is demonstrated in 31.6% of trigeminal nerves and in 22.5% of facial nerves. These results indicate that the contact of REZ of cranial nerve with surrounding artery is not rare in healthy subjects, though causing TN and HFS in particular patients. In this context, we discussed the difference between the contact which is asymptomatic and the compression which is symptomatic. (author)

  11. Correction of inhomogeneous RF field using multiple SPGR signals for high-field spin-echo MRI

    International Nuclear Information System (INIS)

    Ishimori, Yoshiyuki; Monma, Masahiko; Yamada, Kazuhiro; Kimura, Hirohiko; Uematsu, Hidemasa; Fujiwara, Yasuhiro; Yamaguchi, Isao

    2007-01-01

    The purpose of this study was to propose a simple and useful method for correcting nonuniformity of high-field (3 Tesla) T 1 -weighted spin-echo (SE) images based on a B1 field map estimated from gradient recalled echo (GRE) signals. The method of this study was to estimate B1 inhomogeneity, spoiled gradient recalled echo (SPGR) images were collected using a fixed repetition time of 70 ms, flip angles of 45 and 90 degrees, and echo times of 4.8 and 10.4 ms. Selection of flip angles was based on the observation that the relative intensity changes in SPGR signals were very similar among different tissues at larger flip angles than the Ernst angle. Accordingly, spatial irregularity that was observed on a signal ratio map of the SPGR images acquired with these 2 flip angles was ascribed to inhomogeneity of the B1 field. Dual echo time was used to eliminate T 2 * effects. The ratio map that was acquired was scaled to provide an intensity correction map for SE images. Both phantom and volunteer studies were performed using a 3T magnetic resonance scanner to validate the method. In the phantom study, the uniformity of the T 1 -weighted SE image improved by 23%. Images of human heads also showed practically sufficient improvement in the image uniformity. The present method improves the image uniformity of high-field T 1 -weighted SE images. (author)

  12. Chondromalacia of the knee: evaluation with a fat-suppression three-dimensional SPGR imaging after intravenous contrast injection.

    Science.gov (United States)

    Suh, J S; Cho, J H; Shin, K H; Kim, S J

    1996-01-01

    Twenty-one MRI studies with a fat-suppression three-dimensional spoiled gradient-recalled echo in a steady state (3D SPGR) pulse sequence after intravenous contrast injection were evaluated to assess the accuracy in depicting chondromalacia of the knee. On the basis of MR images, chondromalacia and its grade were determined in each of five articular cartilage regions (total, 105 regions) and then the results were compared to arthroscopic findings. The sensitivity, specificity, and accuracy of MRI were 70%, 99%, and 93%, respectively. MR images depicted 7 of 11 lesions of arthroscopic grade 1 or 2 chondromalacia, and seven of nine lesions of arthroscopic grade 3 or 4 chondromalacia. The cartilage abnormalities in all cases appeared as focal lesions with high signal intensity. Intravenous contrast-injection, fat-suppression 3D SPGR imaging showed high specificity in excluding cartilage abnormalities and may be considered as an alternative to intra-articular MR arthrography when chondromalacia is suspected.

  13. Comparative study of 3D TOF-SPGR and 3D FASE on the display of the relationship between cranial nerves and peripheral vessels

    International Nuclear Information System (INIS)

    Sun Wenge; Li Yanliang; Zhang Lina; Qi Xixun; Jin Anyu; Xu Ke; Tong Zhiyong; Liu Jing

    2004-01-01

    Objective: To select a better sequence which can supply reliable radiological information for vessel compression on cranial nerves in patients with facial spasm or trigeminal neuralgia. Methods: 3D TOF-SPGR and 3D FASE were used in 40 patients with facial spasm or trigeminal neuralgia to display the relationship between cranial nerves (facial nerve and trigeminal nerve) and peripheral vessels. Results: 38 patients got surgical results. 33 unilateral vessel compression or contact on facial nerves or trigeminal nerves was found on 3D TOF-SPGR, while no contact was found in 5. 26 unilateral vessel compression or contact on facial nerves or trigeminal nerves was found on 3D FASE, while no contact was found in 12. Significant difference between the two sequences on the display of vessel compression on facial nerves or trigeminal nerves was found by statistical analysis (χ 2 =5.14, P=0.016). Conclusion: 3D TOF-SPGR is better than 3D FASE on display of the relationship between nerves and peripheral vessels, and it should be the primary MRI sequence for patients with facial spasm or trigeminal neuralgia clinically. (author)

  14. The importance of role distribution in working groups : an evaluation of two different groups working in the same environment based on self-evaluation and observer-reported data by the use of SPGR-Systematizing the Person Group Relation

    OpenAIRE

    Nyheim, Linda

    2007-01-01

    ABSTRACT The present thesis examines personal and group relations. Two groups served as the study context: one group of doctors and one group of nurses. SPGR – Systematizing the Person Group Relation – was used as a framework. SPGR is a theory on how behaviour and relations develop in groups and organizations. The purpose of the study was to investigate typical tendencies in groups to identify the prevailing functions based on the formative SPGR dimensions Nurture, Dependency, Contro...

  15. Parallel imaging enhanced MR colonography using a phantom model.

    LENUS (Irish Health Repository)

    Morrin, Martina M

    2008-09-01

    To compare various Array Spatial and Sensitivity Encoding Technique (ASSET)-enhanced T2W SSFSE (single shot fast spin echo) and T1-weighted (T1W) 3D SPGR (spoiled gradient recalled echo) sequences for polyp detection and image quality at MR colonography (MRC) in a phantom model. Limitations of MRC using standard 3D SPGR T1W imaging include the long breath-hold required to cover the entire colon within one acquisition and the relatively low spatial resolution due to the long acquisition time. Parallel imaging using ASSET-enhanced T2W SSFSE and 3D T1W SPGR imaging results in much shorter imaging times, which allows for increased spatial resolution.

  16. Quantitative Gd-DOTA uptake from cerebrospinal fluid into rat brain using 3D VFA-SPGR at 9.4T.

    Science.gov (United States)

    Lee, Hedok; Mortensen, Kristian; Sanggaard, Simon; Koch, Palle; Brunner, Hans; Quistorff, Bjørn; Nedergaard, Maiken; Benveniste, Helene

    2018-03-01

    We propose a quantitative technique to assess solute uptake into the brain parenchyma based on dynamic contrast-enhanced MRI (DCE-MRI). With this approach, a small molecular weight paramagnetic contrast agent (Gd-DOTA) is infused in the cerebral spinal fluid (CSF) and whole brain gadolinium concentration maps are derived. We implemented a 3D variable flip angle spoiled gradient echo (VFA-SPGR) longitudinal relaxation time (T1) technique, the accuracy of which was cross-validated by way of inversion recovery rapid acquisition with relaxation enhancement (IR-RARE) using phantoms. Normal Wistar rats underwent Gd-DOTA infusion into CSF via the cisterna magna and continuous MRI for approximately 130 min using T1-weighted imaging. Dynamic Gd-DOTA concentration maps were calculated and parenchymal uptake was estimated. In the phantom study, T1 discrepancies between the VFA-SPGR and IR-RARE sequences were approximately 6% with a transmit coil inhomogeneity correction. In the in vivo study, contrast transport profiles indicated maximal parenchymal retention of approximately 19% relative to the total amount delivered into the cisterna magna. Imaging strategies for accurate 3D contrast concentration mapping at 9.4T were developed and whole brain dynamic concentration maps were derived to study solute transport via the glymphatic system. The newly developed approach will enable future quantitative studies of the glymphatic system in health and disease states. Magn Reson Med 79:1568-1578, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  17. The role of 3D volumetric MR sequences in diagnosing intraventricular neurocysticercosis: preliminar results

    Directory of Open Access Journals (Sweden)

    Francisco Edward Frota Mont'Alverne Filho

    2011-02-01

    Full Text Available OBJECTIVE: The purpose of this paper was to investigate the role of two three-dimensional magnetic resonance (MRI sequences: enhanced spoiled gradient recalled echo (SPGR, and fast imaging employing steady-state acquisition (FIESTA in the evaluation of intraventricular neurocysticercosis cysts and scolices. METHOD: Seven neurocysticercosis patients suspected of presenting intraventricular lesions were evaluated by magnetic resonance imaging using enhanced SPGR, and FIESTA. RESULTS: Enhanced SPGR detected eight cystic lesions, with scolices in four. Contrast enhancement was observed in three cysts. FIESTA also detected eight cystic lesions with the presence of scolices in seven of those cystic lesions. Four patients presented parenchymal involvement, while the remaining three presented the racemose form. CONCLUSION: FIESTA and SPGR are sequences that can detect intraventricular cysts of neurocysticercosis, and FIESTA also is good for the detection of the scolex. Considering this information we suggest that FIESTA and SPGR should be included in the MRI protocol for the investigation of intraventricular neurocysticercosis.

  18. Magnetic resonance cisternography using the fast spin echo method for the evaluation of vestibular schwannoma

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, Shigeru; Yokoyama, Tetsuo; Uemura, Kenichi [Hamamatsu Univ. School of Medicine, Shizuoka (Japan)

    1999-04-01

    Neuroimaging of vestibular schwannoma was performed with the fat-suppression spoiled gradient recalled acquisition in the steady state (SPGR) method and magnetic resonance (MR) cisternography, which is a fast spin echo method using a long echo train length, for the preoperative evaluation of the lateral extension of the tumor in the internal auditory canal, and the anatomical identification of the posterior semicircular canal and the nerves in the canal distal to the tumor. The SPGR method overestimated the lateral extension in eight cases, probably because of enhancement of the nerves adjacent to the tumor in the canal. The posterior semicircular canal could not be clearly identified, and the cranial nerves in the canal were shown only as a nerve bundle. In contrast, MR cisternography showed clear images of the lateral extension of the tumor and the facial and cochlear nerves adjacent to the tumor in the internal auditory canal. The anatomical location of the posterior semicircular canal was also clearly shown. These preoperative findings are very useful to plan the extent to which the internal auditory canal can be opened, and for intraoperative identification of the nerves in the canal. MR cisternography is less invasive since no contrast material or radiation is required, as with thin-slice high-resolution computed tomography (CT). MR cisternography should replace high-resolution CT for the preoperative neuroradiological evaluation of vestibular schwannoma. (author)

  19. MR imaging of the cranial nerves and the intracranial vessels using 3D-SPGR

    International Nuclear Information System (INIS)

    Hosoya, Takaaki; Sato, Nami; Yamaguchi, Koichi; Sugai, Yukio; Ogushi, Masatoshi; Kubota, Hisashi

    1992-01-01

    MR angiography (MRA) has developed rapidly, but it is still insufficient to demonstrate the detail of the intracranial vascular anatomy. We found that original images of MRA render more information than MRA images about not only intracranial vessels but also cranial nerves. We have tried to demonstrate cranial nerves and intracranial vessels on 26 patients and evaluated using real time reformation of original images of MRA. MR images were obtained by SPGR (3DFT) after injection of Gd-DTPA. The optic nerve, the oculomotor nerve, the trigeminal nerve, the facial nerve and the vestibulocochlear nerve were visualized clearly on almost patients and detectabilities of these nerves were 100%, 98%, 100%, 94% and 100%, respectively. The abducent nerve was also detectable in 76%. The trochlear nerve, which could not be observed by any modality, was detected at prepontine cistern in 10%. Arteries around brain stem such as the superior cerebellar artery (SCA), the anterior inferior cerebellar artery (AICA), the posterior inferior cerebellar artery (PICA) and the posterior communicating artery (PcomA) were clearly visible, and branching of these arteries and anatomical detail were completely coincide with angiogram on 12 patients. The basal vein of Rosenthal and the petrosal vein were confirmed in 100% and their anastomose were demonstrated obviously. We concluded that this method was extremely useful to observe cranial nerves and intracranial small vessels. (author)

  20. IDEAL 3D spoiled gradient echo of the articular cartilage of the knee on 3.0 T MRI: a comparison with conventional 3.0 T fast spin-echo T2 fat saturation image.

    Science.gov (United States)

    Han, Chul Hee; Park, Hee Jin; Lee, So Yeon; Chung, Eun Chul; Choi, Seon Hyeong; Yun, Ji Sup; Rho, Myung Ho

    2015-12-01

    Many two-dimensional (2D) morphologic cartilage imaging sequences have disadvantages such as long acquisition time, inadequate spatial resolution, suboptimal tissue contrast, and image degradation secondary to artifacts. IDEAL imaging can overcome these disadvantages. To compare sound-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and quality of two different methods of imaging that include IDEAL 3D SPGR and 3.0-T FSE T2 fat saturation (FS) imaging and to evaluate the utility of IDEAL 3D SPGR for knee joint imaging. SNR and CNR of the patellar and femoral cartilages were measured and calculated. Two radiologists performed subjective scoring of all images for three measures: general image quality, FS, and cartilage evaluation. SNR and CNR values were compared by paired Student's t-tests. Mean SNRs of patellar and femoral cartilages were 90% and 66% higher, respectively, for IDEAL 3D SPGR. CNRs of patellar cartilages and joint fluids were 2.4 times higher for FSE T2 FS, and CNR between the femoral cartilage and joint fluid was 2.2 times higher for FSE T2 FS. General image quality and FS were superior using FSE T2 FS compared to those of IDEAL 3D SPGR imaging according to both readers, while cartilage evaluation was superior using IDEAL 3D SPGR. Additionally, cartilage injuries were more prominent in IDEAL 3D SPGR than in FSE T2FS according to both readers. IDEAL 3D SPGR images show excellent visualization of patellar and femoral cartilages in 3.0 T and can compensate for the weaknesses of FSE T2 FS in the evaluation of cartilage injuries. © The Foundation Acta Radiologica 2014.

  1. Quantum-Sequencing: Fast electronic single DNA molecule sequencing

    Science.gov (United States)

    Casamada Ribot, Josep; Chatterjee, Anushree; Nagpal, Prashant

    2014-03-01

    A major goal of third-generation sequencing technologies is to develop a fast, reliable, enzyme-free, high-throughput and cost-effective, single-molecule sequencing method. Here, we present the first demonstration of unique ``electronic fingerprint'' of all nucleotides (A, G, T, C), with single-molecule DNA sequencing, using Quantum-tunneling Sequencing (Q-Seq) at room temperature. We show that the electronic state of the nucleobases shift depending on the pH, with most distinct states identified at acidic pH. We also demonstrate identification of single nucleotide modifications (methylation here). Using these unique electronic fingerprints (or tunneling data), we report a partial sequence of beta lactamase (bla) gene, which encodes resistance to beta-lactam antibiotics, with over 95% success rate. These results highlight the potential of Q-Seq as a robust technique for next-generation sequencing.

  2. Accuracy of single photoelectron time spread measurement of fast photomultipliers

    International Nuclear Information System (INIS)

    Leskovar, B.

    1975-01-01

    The accuracy of time spread measurements of fast photomultipliers was investigated, using single photoelectrons. The effect of the finite light pulse width on the measurement accuracy was determined and discussed. Experimental data were obtained on a special measuring system for light pulse widths ranging from 200 psec to 10 nsec, using fast photomultipliers 8850 and C31024 with optimized operating conditions for minimum transit time spread. A modified exponential function expression and curve-fitting parameters are given, which fit closely the experimentally obtained data over a wide dynamic range of light pulse widths. (U.S.)

  3. Single bunch fast longitudinal instability

    International Nuclear Information System (INIS)

    Wang, J.M.; Pellegrini, C.

    1979-01-01

    Single bunch longitudinal instability producing an increase of the bunch areas has been observed in proton synchrotron and storage rings. Singals at microwave frequencies are observed during the bunch blow-up and because of this the effect has been called the microwave instability. A similar increase in bunch area is observed also in electron storage rings, where it is usually referred to as the bunch lengthening effect. This paper is an attempt to obtain a more general theory of this effect. Here we describe the model used and the method of calculation, together with some general results. The main result of this paper is the derivation of a condition for the existence of a fast longitudinal bunch blow-up. This condition is a generalized threshold formula, showing explicitly the dependence on the bunch energy spread and length

  4. Sintering behavior of porous wall tile bodies during fast single-firing process

    Directory of Open Access Journals (Sweden)

    Sidnei José Gomes Sousa

    2005-06-01

    Full Text Available In ceramic wall tile processing, fast single-firing cycles have been widely used. In this investigation a fast single-firing porous wall tile mixture was prepared using raw materials from the North Fluminense region.Specimens were obtained by uniaxial pressing and sintered in air at various temperatures (1080 - 1200 °C using a fast-firing cycle (60 minutes. Evolution of the microstructure was followed by XRD and SEM. The results revealed that the main phases formed during the sintering step are anorthite, gehlenite and hematite. It appears that the sintering process is characterized by the presence of a small amount of a liquid phase below 1140 °C. As a result, the microstructure of the ceramic bodies showed a network of small dense zones interconnected with a porous phase. In addition, the strength of the material below 1140 °C appeared to be related to the type and quantity of crystalline phases in the sintered bodies.

  5. Simulating Biomass Fast Pyrolysis at the Single Particle Scale

    Energy Technology Data Exchange (ETDEWEB)

    Ciesielski, Peter [National Renewable Energy Laboratory (NREL); Wiggins, Gavin [ORNL; Daw, C Stuart [ORNL; Jakes, Joseph E. [U.S. Forest Service, Forest Products Laboratory, Madison, Wisconsin, USA

    2017-07-01

    Simulating fast pyrolysis at the scale of single particles allows for the investigation of the impacts of feedstock-specific parameters such as particle size, shape, and species of origin. For this reason particle-scale modeling has emerged as an important tool for understanding how variations in feedstock properties affect the outcomes of pyrolysis processes. The origins of feedstock properties are largely dictated by the composition and hierarchical structure of biomass, from the microstructural porosity to the external morphology of milled particles. These properties may be accounted for in simulations of fast pyrolysis by several different computational approaches depending on the level of structural and chemical complexity included in the model. The predictive utility of particle-scale simulations of fast pyrolysis can still be enhanced substantially by advancements in several areas. Most notably, considerable progress would be facilitated by the development of pyrolysis kinetic schemes that are decoupled from transport phenomena, predict product evolution from whole-biomass with increased chemical speciation, and are still tractable with present-day computational resources.

  6. Single bunch fast longitudinal instability

    International Nuclear Information System (INIS)

    Wang, J.M.; Pellegrini, C.

    1979-01-01

    Single bunch longitudinal instability producing an increase of the bunch area have been observed in proton synchrotron and storage rings. Signals at microwave frequencies are observed during the bunch blow-up and because of this the effect has been called the microwave instability. A similar increase in bunch area is observed also in electron storage rings, where it is usually referred to as the bunch lengthening effect. This paper is an attempt to obtain a more general theory of this effect. Here we describe the model used and the method of calculation, together with some general results. More detailed results will be given in another paper. The main result is the derivation of a condition for the existence of a fast longitudinal bunch blow-up. This condition is a generalized threshold formula, showing explicitly the dependence on the bunch energy spread and length. This condition is qualitatively in agreement with Boussard's suggestion

  7. Single-photon sensitive fast ebCMOS camera system for multiple-target tracking of single fluorophores: application to nano-biophotonics

    Science.gov (United States)

    Cajgfinger, Thomas; Chabanat, Eric; Dominjon, Agnes; Doan, Quang T.; Guerin, Cyrille; Houles, Julien; Barbier, Remi

    2011-03-01

    Nano-biophotonics applications will benefit from new fluorescent microscopy methods based essentially on super-resolution techniques (beyond the diffraction limit) on large biological structures (membranes) with fast frame rate (1000 Hz). This trend tends to push the photon detectors to the single-photon counting regime and the camera acquisition system to real time dynamic multiple-target tracing. The LUSIPHER prototype presented in this paper aims to give a different approach than those of Electron Multiplied CCD (EMCCD) technology and try to answer to the stringent demands of the new nano-biophotonics imaging techniques. The electron bombarded CMOS (ebCMOS) device has the potential to respond to this challenge, thanks to the linear gain of the accelerating high voltage of the photo-cathode, to the possible ultra fast frame rate of CMOS sensors and to the single-photon sensitivity. We produced a camera system based on a 640 kPixels ebCMOS with its acquisition system. The proof of concept for single-photon based tracking for multiple single-emitters is the main result of this paper.

  8. Rats socially-reared and full fed learned an autoshaping task, showing less levels of fear-like behaviour than fasted or singly-reared rats.

    Science.gov (United States)

    Molina-Hernández, Miguel; Téllez-Alcántara, N Patricia

    2004-07-01

    During the learning of instrumental tasks, rats are usually fasted to increase reinforced learning. However, fasting produces several undesirable side effects. The aim of this study was to test the hypothesis that control rats, i.e. full-fed and group-reared rats, will learn an autoshaping task to the same level as fasted or singly-reared rats. The interaction between fasting and single-rearing of rats was also tested. Results showed that control rats and fasted rats acquired the autoshaping task similarly, independently of rearing condition or gender. However, fasted or singly-reared rats produced fear-like behaviour, since male rats group-reared and fasted (85% body/wt, P autoshaping task to the same level as fasted or singly-reared rats. However, fasting or single-rearing produced fear-like behaviour. Thus, the training of control rats in autoshaping tasks may be an option that improves animal welfare.

  9. Fast Excitation and Photon Emission of a Single-Atom-Cavity System

    International Nuclear Information System (INIS)

    Bochmann, J.; Muecke, M.; Langfahl-Klabes, G.; Erbel, C.; Weber, B.; Specht, H. P.; Moehring, D. L.; Rempe, G.

    2008-01-01

    We report on the fast excitation of a single atom coupled to an optical cavity using laser pulses that are much shorter than all other relevant processes. The cavity frequency constitutes a control parameter that allows the creation of single photons in a superposition of two tunable frequencies. Each photon emitted from the cavity thus exhibits a pronounced amplitude modulation determined by the oscillatory energy exchange between the atom and the cavity. Our technique constitutes a versatile tool for future quantum networking experiments

  10. Condition for a single bunch high frequency fast blow-up

    International Nuclear Information System (INIS)

    Wang, J.M.; Pellegrini, C.

    1980-01-01

    We study the longitudinal stability of a single particle bunch in a storage ring using Vlasov equation. We show that the Vlasov equation has solutions corresponding to a fast, microwave instability if a condition on the beam current, qualitatively similar to the stability condition for a coasting beam, is satisfied. This condition can be used to define a threshold current, and to discuss its dependence on the longitudinal coupling impedance

  11. Prevalence of pathologic findings in asymptomatic knees of marathon runners before and after a competition in comparison with physically active subjects-a 3.0 T magnetic resonance imaging study.

    Science.gov (United States)

    Stahl, Robert; Luke, Anthony; Ma, C Benjamin; Krug, Roland; Steinbach, Lynne; Majumdar, Sharmila; Link, Thomas M

    2008-07-01

    To determine the prevalence of pathologic findings in asymptomatic knees of marathon runners before and after a competition in comparison with physically active subjects. To compare the diagnostic performance of cartilage-dedicated magnetic resonance imaging (MRI) sequences at 3.0 T. Ten marathon runners underwent 3.0 T MRI 2-3 days before and after competition. Twelve physically active asymptomatic subjects not performing long-distance running were examined as controls. Pathologic condition was assessed with the whole-organ magnetic resonance imaging score (WORMS). Cartilage abnormalities and bone marrow edema pattern (BMEP) were quantified. Visualization of cartilage pathology was assessed with intermediate-weighted fast spin-echo (IM-w FSE), fast imaging employing steady-state acquisition (FIESTA) and T1-weighted three-dimensional (3D) high-spatial-resolution volumetric fat-suppressed spoiled gradient-echo (SPGR) MRI sequences. Eight of ten marathon runners and 7/12 controls showed knee abnormality. Slightly more and larger cartilage abnormalities, and BMEP, in marathon runners yielded higher but not significantly different WORMS (P > 0.05) than in controls. Running a single marathon did not alter MR findings substantially. Cartilage abnormalities were best visualized with IM-w FSE images (P marathon runners and also in active subjects participating in other recreational sports. IM-w FSE sequences delineated more cartilage MR imaging abnormalities than did FIESTA and SPGR sequences.

  12. Non-contrast MR angiography for diagnosis of congenital heart disease

    International Nuclear Information System (INIS)

    Matsuo, Mikaru; Yoshioka, Kunihiro; Takahashi, Shin; Oyama, Kotaro

    2006-01-01

    Fast imaging employing steady state acquisition (FIESTA) has been reported to be suitable for cardiac imaging in adolescents and adults. The purpose of this study was to establish the applicability and limitation of MR Angiography using FIESTA in the diagnosis of congenital heart disease. Thirty-five patients with congenital heart disease underwent MR Angiography using FIESTA and the 3D Gd-enhanced fast spoiled gradient recalled acquisition in the steady state (SPGR) technique. The measurements of the vascular diameters and diagnostic quality of the two techniques were compared. Correlations between FIESTA and the 3D Gd-fast SPGR technique were excellent in vascular diameter (aAo 0.90, arch 0.78, dAo 0.92, SCA 0.70, RPA 0.90, LPA 0.95). The agreement of the vascular diameters in the Bland-Altman method was good (aAo 0.22 mm, arch 0.07 mm, dAo 0.14 mm, SCA 0.31 mm, RPA 0.45 mm, LPA 0.12 mm). However, MR angiography (MRA) by 3D Gd-enhanced SPGR had a higher resolution than that by FIESTA. Due to signal loss caused at the regions of vascular stenosis or Blalock-Taussig shunt on FIESTA, we could not evaluate the vascular diameter or patency at those lesions. FIESTA is a useful technique of non-enhanced MRA for non-invasive diagnosis of congenital heart disease. However, MRA by FIESTA was not adequate for multiplanar reconstruction. (author)

  13. Fast widely-tunable single-frequency 2-micron laser for remote-sensing applications

    Science.gov (United States)

    Henderson, Sammy W.; Hale, Charley P.

    2017-08-01

    We are developing a family of fast, widely-tunable cw diode-pumped single frequency solid-state lasers, called Swift. The Swift laser architecture is compatible with operation using many different solid-state laser crystals for operation at various emission lines between 1 and 2.1 micron. The initial prototype Swift laser using a Tm,Ho:YLF laser crystal near 2.05 micron wavelength achieved over 100 mW of single frequency cw output power, up to 50 GHz-wide, fast, mode-hop-free piezoelectric tunability, and 100 kHz/ms frequency stability. For the Tm,Ho:YLF laser material, the fast 50 GHz tuning range can be centered at any wavelength from 2047-2059 nm using appropriate intracavity spectral filters. The frequency stability and power are sufficient to serve as the local oscillator (LO) laser in long-range coherent wind-measuring lidar systems, as well as a frequency-agile master oscillator (MO) or injection-seed source for larger pulsed transmitter lasers. The rapid and wide frequency tunablity meets the requirements for integrated-path or range-resolved differential absorption lidar or applications where targets with significantly different line of sight velocities (Doppler shifts) must be tracked. Initial demonstration of an even more compact version of the Swift is also described which requires less prime power and produces less waste heat.

  14. Comparing SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout

    Science.gov (United States)

    England, Troy; Curry, Matthew; Carr, Stephen; Mounce, Andrew; Jock, Ryan; Sharma, Peter; Bureau-Oxton, Chloe; Rudolph, Martin; Hardin, Terry; Carroll, Malcolm

    Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will compare two amplifiers based on single-transistor circuits implemented with silicon germanium heterojunction bipolar transistors. Both amplifiers provide gain at low power levels, but the dynamics of each circuit vary significantly. We will explore the gain mechanisms, linearity, and noise of each circuit and explain the situations in which each amplifier is best used. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000.

  15. Synchronous timing of multi-energy fast beam extraction during a single AGS cycle

    International Nuclear Information System (INIS)

    Gabusi, J.; Naase, S.

    1985-01-01

    Synchronous triggering of fast beams is required because the field of Kicker Magnets must rise within the open space between one beam bunch and the next. Within the Brookhaven AGS, Fast Extracted Beam (FEB) triggering combines nominal timing, based on beam energy with bunch-to-bunch synchronization, based on the accelerating rf waveform. During beam acceleration, a single bunch is extracted at 22 GeV/c and within the same AGS cycle, the remaining eleven bunches are extracted at 28.4 GeV/c. When the single bunch is extracted, a ''hole'', which is left in the remaining circulating beam, can appear in random locations within the second extraction during successive AGS cycles. To overcome this problem, a synchronous rf/12 counting scheme and logic circuitry are used to keep track of the bunch positions relative to each other, and to place the ''hole'' in any desired location within the second extraction. The rf/12 signal is used also to synchronize experimenters triggers

  16. Prevalence of pathologic findings in asymptomatic knees of marathon runners before and after a competition in comparison with physically active subjects - a 3.0 T magnetic resonance imaging study

    International Nuclear Information System (INIS)

    Stahl, Robert; Luke, Anthony; Ma, C.B.; Krug, Roland; Steinbach, Lynne; Majumdar, Sharmila; Link, Thomas M.

    2008-01-01

    To determine the prevalence of pathologic findings in asymptomatic knees of marathon runners before and after a competition in comparison with physically active subjects. To compare the diagnostic performance of cartilage-dedicated magnetic resonance imaging (MRI) sequences at 3.0 T. Ten marathon runners underwent 3.0 T MRI 2-3 days before and after competition. Twelve physically active asymptomatic subjects not performing long-distance running were examined as controls. Pathologic condition was assessed with the whole-organ magnetic resonance imaging score (WORMS). Cartilage abnormalities and bone marrow edema pattern (BMEP) were quantified. Visualization of cartilage pathology was assessed with intermediate-weighted fast spin-echo (IM-w FSE), fast imaging employing steady-state acquisition (FIESTA) and T1-weighted three-dimensional (3D) high-spatial-resolution volumetric fat-suppressed spoiled gradient-echo (SPGR) MRI sequences. Eight of ten marathon runners and 7/12 controls showed knee abnormality. Slightly more and larger cartilage abnormalities, and BMEP, in marathon runners yielded higher but not significantly different WORMS (P > 0.05) than in controls. Running a single marathon did not alter MR findings substantially. Cartilage abnormalities were best visualized with IM-w FSE images (P < 0.05). A high prevalence of knee abnormalities was found in marathon runners and also in active subjects participating in other recreational sports. IM-w FSE sequences delineated more cartilage MR imaging abnormalities than did FIESTA and SPGR sequences. (orig.)

  17. Prevalence of pathologic findings in asymptomatic knees of marathon runners before and after a competition in comparison with physically active subjects - a 3.0 T magnetic resonance imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Stahl, Robert [University of California, San Francisco, Musculoskeletal and Quantitative Imaging Group, Department of Radiology, San Francisco, CA (United States); Ludwig Maximilians University of Munich, Department of Clinical Radiology, University Hospitals-Campus Grosshadern, Munich (Germany); Luke, Anthony [University of California, San Francisco, Department of Orthopedic Surgery, San Francisco, CA (United States); University of California, San Francisco, Department of Family and Community Medicine, San Francisco, CA (United States); Ma, C.B. [University of California, San Francisco, Department of Orthopedic Surgery, San Francisco, CA (United States); Krug, Roland; Steinbach, Lynne; Majumdar, Sharmila; Link, Thomas M. [University of California, San Francisco, Musculoskeletal and Quantitative Imaging Group, Department of Radiology, San Francisco, CA (United States)

    2008-07-15

    To determine the prevalence of pathologic findings in asymptomatic knees of marathon runners before and after a competition in comparison with physically active subjects. To compare the diagnostic performance of cartilage-dedicated magnetic resonance imaging (MRI) sequences at 3.0 T. Ten marathon runners underwent 3.0 T MRI 2-3 days before and after competition. Twelve physically active asymptomatic subjects not performing long-distance running were examined as controls. Pathologic condition was assessed with the whole-organ magnetic resonance imaging score (WORMS). Cartilage abnormalities and bone marrow edema pattern (BMEP) were quantified. Visualization of cartilage pathology was assessed with intermediate-weighted fast spin-echo (IM-w FSE), fast imaging employing steady-state acquisition (FIESTA) and T1-weighted three-dimensional (3D) high-spatial-resolution volumetric fat-suppressed spoiled gradient-echo (SPGR) MRI sequences. Eight of ten marathon runners and 7/12 controls showed knee abnormality. Slightly more and larger cartilage abnormalities, and BMEP, in marathon runners yielded higher but not significantly different WORMS (P > 0.05) than in controls. Running a single marathon did not alter MR findings substantially. Cartilage abnormalities were best visualized with IM-w FSE images (P < 0.05). A high prevalence of knee abnormalities was found in marathon runners and also in active subjects participating in other recreational sports. IM-w FSE sequences delineated more cartilage MR imaging abnormalities than did FIESTA and SPGR sequences. (orig.)

  18. Thermal and fast neutron dosimetry using artificial single crystal diamond detectors

    International Nuclear Information System (INIS)

    Angelone, M.; Pillon, M.; Prestopino, G.; Marinelli, Marco; Milani, E.; Verona, C.; Verona-Rinati, G.; Aielli, G.; Cardarelli, R.; Santonico, R.; Bedogni, R.; Esposito, A.

    2011-01-01

    In this work we propose the artificial Single Crystal Diamond (SCD) detector covered with a thin layer (0.5 μm/4 μm) of 6 LiF as a simultaneous thermal and fast neutron fluence monitor. Some interesting properties of the diamond response versus the neutron energy are evidenced thanks to Monte Carlo simulation using the MCNPX code which allows to propose the diamond detector also as an ambient dose equivalent (H∗(10)) monitor (REM counter).

  19. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout

    Science.gov (United States)

    England, Troy; Lilly, Michael; Curry, Matthew; Carr, Stephen; Carroll, Malcolm

    Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout of electrons bound to Si:P donors. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will introduce two new amplifier topologies that provide excellent gain versus power tradeoffs using silicon-germanium (SiGe) heterojunction bipolar transistors (HBTs). The AC HBT allows in-situ adjustment of power dissipation during an experiment and can provide gain in the millikelvin temperature regime while dissipating less than 500 nW. The AC Current Amplifier maximizes gain at nearly 800 A/A. We will also show results of using these amplifiers with SETs at 4 K. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout.

  20. Physicochemical properties of bio-oil and biochar produced by fast pyrolysis of stored single-pass corn stover and cobs.

    Science.gov (United States)

    Shah, Ajay; Darr, Matthew J; Dalluge, Dustin; Medic, Dorde; Webster, Keith; Brown, Robert C

    2012-12-01

    Short harvest window of corn (Zea mays) stover necessitates its storage before utilization; however, there is not enough work towards exploring the fast pyrolysis behavior of stored biomass. This study investigated the yields and the physicochemical properties (proximate and ultimate analyses, higher heating values and acidity) of the fast pyrolysis products obtained from single-pass stover and cobs stored either inside a metal building or anaerobically within plastic wraps. Biomass samples were pyrolyzed in a 183 cm long and 2.1cm inner diameter free-fall fast pyrolysis reactor. Yields of bio-oil, biochar and non-condensable gases from different biomass samples were in the ranges of 45-55, 25-37 and 11-17 wt.%, respectively, with the highest bio-oil yield from the ensiled single-pass stover. Bio-oils generated from ensiled single-pass cobs and ensiled single-pass stover were, respectively, the most and the least acidic with the modified acid numbers of 95.0 and 65.2 mg g(-1), respectively. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Fast single image dehazing based on image fusion

    Science.gov (United States)

    Liu, Haibo; Yang, Jie; Wu, Zhengping; Zhang, Qingnian

    2015-01-01

    Images captured in foggy weather conditions often fade the colors and reduce the contrast of the observed objects. An efficient image fusion method is proposed to remove haze from a single input image. First, the initial medium transmission is estimated based on the dark channel prior. Second, the method adopts an assumption that the degradation level affected by haze of each region is the same, which is similar to the Retinex theory, and uses a simple Gaussian filter to get the coarse medium transmission. Then, pixel-level fusion is achieved between the initial medium transmission and coarse medium transmission. The proposed method can recover a high-quality haze-free image based on the physical model, and the complexity of the proposed method is only a linear function of the number of input image pixels. Experimental results demonstrate that the proposed method can allow a very fast implementation and achieve better restoration for visibility and color fidelity compared to some state-of-the-art methods.

  2. Ultra-fast scintillation properties of β-Ga2O3 single crystals grown by Floating Zone method

    Science.gov (United States)

    He, Nuotian; Tang, Huili; Liu, Bo; Zhu, Zhichao; Li, Qiu; Guo, Chao; Gu, Mu; Xu, Jun; Liu, Jinliang; Xu, Mengxuan; Chen, Liang; Ouyang, Xiaoping

    2018-04-01

    In this investigation, β-Ga2O3 single crystals were grown by the Floating Zone method. At room temperature, the X-ray excited emission spectrum includes ultraviolet and blue emission bands. The scintillation light output is comparable to the commercial BGO scintillator. The scintillation decay times are composed of the dominant ultra-fast component of 0.368 ns and a small amount of slightly slow components of 8.2 and 182 ns. Such fast component is superior to most commercial inorganic scintillators. In contrast to most semiconductor crystals prepared by solution method such as ZnO, β-Ga2O3 single crystals can be grown by traditional melt-growth method. Thus we can easily obtain large bulk crystals and mass production.

  3. Fast all-optical flip-flop based on a single distributed feedback laser diode.

    Science.gov (United States)

    Huybrechts, Koen; Morthier, Geert; Baets, Roel

    2008-07-21

    Since there is an increasing demand for fast networks and switches, the electronic data processing imposes a severe bottleneck and all-optical processing techniques will be required in the future. All-optical flip-flops are one of the key components because they can act as temporary memory elements. Several designs have already been demonstrated but they are often relatively slow or complex to fabricate. We demonstrate experimentally fast flip-flop operation in a single DFB laser diode which is one of the standard elements in today's telecommunication industry. Injecting continuous wave light in the laser diode, a bistability is obtained due to the spatial hole burning effect. We can switch between the two states by using pulses with energies below 200 fJ resulting in flip-flop operation with switching times below 75 ps and repetition rates of up to 2 GHz.

  4. Fast measurement of luminosity at LEP by detecting the single bremsstrahlung photons

    International Nuclear Information System (INIS)

    Bini, C.; De Zorzi, G.; Diambrini Palazzi, G.; Di Cosimo, G.; Di Domenico, A.; Gauzzi, P.; Zanello, D.

    1991-01-01

    Luminosity and beam angular divergence have been measured at LEP with a fast monitor based on the single bremsstrahlung process e + e - → e + e - γ. The photons emitted at the interaction point 1 are detected by an electromagnetic calorimeter: both the photon energy and the impact point are measured. The beam angular divergence and the luminosity are determined in few minutes with a statistical error of 1%. With the present experimental layout the systematic error is of few percent; it would be reduced by performing the measurement on an experimental interaction point. (orig.)

  5. An automated and fast approach to detect single-trial visual evoked potentials with application to brain-computer interface.

    Science.gov (United States)

    Tu, Yiheng; Hung, Yeung Sam; Hu, Li; Huang, Gan; Hu, Yong; Zhang, Zhiguo

    2014-12-01

    This study aims (1) to develop an automated and fast approach for detecting visual evoked potentials (VEPs) in single trials and (2) to apply the single-trial VEP detection approach in designing a real-time and high-performance brain-computer interface (BCI) system. The single-trial VEP detection approach uses common spatial pattern (CSP) as a spatial filter and wavelet filtering (WF) a temporal-spectral filter to jointly enhance the signal-to-noise ratio (SNR) of single-trial VEPs. The performance of the joint spatial-temporal-spectral filtering approach was assessed in a four-command VEP-based BCI system. The offline classification accuracy of the BCI system was significantly improved from 67.6±12.5% (raw data) to 97.3±2.1% (data filtered by CSP and WF). The proposed approach was successfully implemented in an online BCI system, where subjects could make 20 decisions in one minute with classification accuracy of 90%. The proposed single-trial detection approach is able to obtain robust and reliable VEP waveform in an automatic and fast way and it is applicable in VEP based online BCI systems. This approach provides a real-time and automated solution for single-trial detection of evoked potentials or event-related potentials (EPs/ERPs) in various paradigms, which could benefit many applications such as BCI and intraoperative monitoring. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  6. Measurement, modeling, and simulation of cryogenic SiGe HBT amplifier circuits for fast single spin readout

    Science.gov (United States)

    England, Troy; Curry, Matthew; Carr, Steve; Swartzentruber, Brian; Lilly, Michael; Bishop, Nathan; Carrol, Malcolm

    2015-03-01

    Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout of electrons bound to Si:P donors. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance typical of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will discuss calibration data, as well as modeling and simulation of cryogenic silicon-germanium (SiGe) heterojunction bipolar transistor (HBT) circuits connected to a silicon SET and operating at 4 K. We find a continuum of solutions from simple, single-HBT amplifiers to more complex, multi-HBT circuits suitable for integration, with varying noise levels and power vs. bandwidth tradeoffs. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000.

  7. Mechanisms for Selective Single-Cell Reactivation during Offline Sharp-Wave Ripples and Their Distortion by Fast Ripples.

    Science.gov (United States)

    Valero, Manuel; Averkin, Robert G; Fernandez-Lamo, Ivan; Aguilar, Juan; Lopez-Pigozzi, Diego; Brotons-Mas, Jorge R; Cid, Elena; Tamas, Gabor; Menendez de la Prida, Liset

    2017-06-21

    Memory traces are reactivated selectively during sharp-wave ripples. The mechanisms of selective reactivation, and how degraded reactivation affects memory, are poorly understood. We evaluated hippocampal single-cell activity during physiological and pathological sharp-wave ripples using juxtacellular and intracellular recordings in normal and epileptic rats with different memory abilities. CA1 pyramidal cells participate selectively during physiological events but fired together during epileptic fast ripples. We found that firing selectivity was dominated by an event- and cell-specific synaptic drive, modulated in single cells by changes in the excitatory/inhibitory ratio measured intracellularly. This mechanism collapses during pathological fast ripples to exacerbate and randomize neuronal firing. Acute administration of a use- and cell-type-dependent sodium channel blocker reduced neuronal collapse and randomness and improved recall in epileptic rats. We propose that cell-specific synaptic inputs govern firing selectivity of CA1 pyramidal cells during sharp-wave ripples. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Attenuation of Reactor Gamma Radiation and Fast Neutrons Through Large Single-Crystal Materials

    International Nuclear Information System (INIS)

    Adib, M.

    2009-01-01

    A generalized formula is given which, for neutron energies in the range 10-4< E< 10 eV and gamma rays with average energy 2 MeV , permits calculation of the transmission properties of several single crystal materials important for neutron scattering instrumentation. A computer program Filter was developed which permits the calculation of attenuation of gamma radiation, nuclear capture, thermal diffuse and Bragg-scattering cross-sections as a function of materials constants, temperature and neutron energy. The applicability of the deduced formula along with the code checked from the obtained agreement between the calculated and experimental neutron transmission through various single-crystals A feasibility study for use of Si, Ge, Pb, Bi and sapphire is detailed in terms of optimum crystal thickness, mosaic spread and cutting plane for efficient transmission of thermal reactor neutrons and for rejection of the accompanying fast neutrons and gamma rays.

  9. A Method for Extracting the Free Energy Surface and Conformational Dynamics of Fast-Folding Proteins from Single Molecule Photon Trajectories

    Science.gov (United States)

    2015-01-01

    Single molecule fluorescence spectroscopy holds the promise of providing direct measurements of protein folding free energy landscapes and conformational motions. However, fulfilling this promise has been prevented by technical limitations, most notably, the difficulty in analyzing the small packets of photons per millisecond that are typically recorded from individual biomolecules. Such limitation impairs the ability to accurately determine conformational distributions and resolve sub-millisecond processes. Here we develop an analytical procedure for extracting the conformational distribution and dynamics of fast-folding proteins directly from time-stamped photon arrival trajectories produced by single molecule FRET experiments. Our procedure combines the maximum likelihood analysis originally developed by Gopich and Szabo with a statistical mechanical model that describes protein folding as diffusion on a one-dimensional free energy surface. Using stochastic kinetic simulations, we thoroughly tested the performance of the method in identifying diverse fast-folding scenarios, ranging from two-state to one-state downhill folding, as a function of relevant experimental variables such as photon count rate, amount of input data, and background noise. The tests demonstrate that the analysis can accurately retrieve the original one-dimensional free energy surface and microsecond folding dynamics in spite of the sub-megahertz photon count rates and significant background noise levels of current single molecule fluorescence experiments. Therefore, our approach provides a powerful tool for the quantitative analysis of single molecule FRET experiments of fast protein folding that is also potentially extensible to the analysis of any other biomolecular process governed by sub-millisecond conformational dynamics. PMID:25988351

  10. Ramadan Fasting in Kidney Transplant Recipients: A Single-Centre Retrospective Study

    Directory of Open Access Journals (Sweden)

    Ihab A. Ibrahim

    2018-01-01

    Full Text Available Background. Fasting during the lunar month of Ramadan is mandatory to all healthy adult Muslims. Renal transplant recipients are often worried about the impact of fluid and electrolyte deprivation during fasting on the function of their allograft. We aimed to examine the effect of fasting Ramadan on the graft function in renal transplant recipients. Methods. This retrospective cohort study included patients who underwent kidney transplantation in our tertiary referral center. Baseline pre-Ramadan estimated glomerular filtration rate (eGFR, mean arterial pressure (MAP, and urinary protein excretion were compared to those during and after Ramadan within and between the fasting and non-fasting groups. Results. The study population included 280 kidney transplant recipients who chose to fast during the Ramadan month (June-July 2014 and 285 recipients who did not fast. In the fasting group, baseline eGFR did not change from that during or post-Ramadan (72.6±23.7 versus 72.3±24.5 mL/min/1.73 m2, P=0.53; and 72.6±23.7 versus 72±23.2 mL/min/1.73 m2, P=0.14, respectively. Compared to baseline, there were no significant differences between the fasting and the non-fasting groups in terms of mean percent changes in eGFR, MAP, and urinary protein excretion. Conclusion. Fasting during the month of Ramadan did not have significant adverse effects on renal allograft function.

  11. High-resolution T1-weighted 3D real IR imaging of the temporal bone using triple-dose contrast material

    Energy Technology Data Exchange (ETDEWEB)

    Naganawa, Shinji; Koshikawa, Tokiko; Nakamura, Tatsuya; Fukatsu, Hiroshi; Ishigaki, Takeo [Department of Radiology, Nagoya University School of Medicine, 65 Tsurumai-cho, Shouwa-ku, 466-8550, Nagoya (Japan); Aoki, Ikuo [Medical System Company, Toshiba Corporation, Tokyo (Japan)

    2003-12-01

    The small structures in the temporal bone are surrounded by bone and air. The objectives of this study were (a) to compare contrast-enhanced T1-weighted images acquired by fast spin-echo-based three-dimensional real inversion recovery (3D rIR) against those acquired by gradient echo-based 3D SPGR in the visualization of the enhancement of small structures in the temporal bone, and (b) to determine whether either 3D rIR or 3D SPGR is useful for visualizing enhancement of the cochlear lymph fluid. Seven healthy men (age range 27-46 years) volunteered to participate in this study. All MR imaging was performed using a dedicated bilateral quadrature surface phased-array coil for temporal bone imaging at 1.5 T (Visart EX, Toshiba, Tokyo, Japan). The 3D rIR images (TR/TE/TI: 1800 ms/10 ms/500 ms) and flow-compensated 3D SPGR images (TR/TE/FA: 23 ms/10 ms/25 ) were obtained with a reconstructed voxel size of 0.6 x 0.7 x 0.8 mm{sup 3}. Images were acquired before and 1, 90, 180, and 270 min after the administration of triple-dose Gd-DTPA-BMA (0.3 mmol/kg). In post-contrast MR images, the degree of enhancement of the cochlear aqueduct, endolymphatic sac, subarcuate artery, geniculate ganglion of the facial nerve, and cochlear lymph fluid space was assessed by two radiologists. The degree of enhancement was scored as follows: 0 (no enhancement); 1 (slight enhancement); 2 (intermediate between 1 and 3); and 3 (enhancement similar to that of vessels). Enhancement scores for the endolymphatic sac, subarcuate artery, and geniculate ganglion were higher in 3D rIR than in 3D SPGR. Washout of enhancement in the endolymphatic sac appeared to be delayed compared with that in the subarcuate artery, suggesting that the enhancement in the endolymphatic sac may have been due in part to non-vascular tissue enhancement. Enhancement of the cochlear lymph space was not observed in any of the subjects in 3D rIR and 3D SPGR. The 3D rIR sequence may be more sensitive than the 3D SPGR sequence in

  12. Moderately T2-weighted images obtained with the single-shot fast spin-echo technique. Differentiating between malignant and benign urinary obstructions

    International Nuclear Information System (INIS)

    Obuchi, Masao; Sugimoto, Hideharu; Kubota, Hayato; Yamamoto, Wakako; Kinebuchi, Yuko; Honda, Minoru; Takahara, Taro

    2002-01-01

    The purpose of this study was to determine whether a distinction could be made between benign and malignant urinary obstructions in moderately T 2 -weighted images obtained with the single-shot fast spin-echo technique. Forty-four lesions in 39 patients with urinary obstruction were evaluated with the single-shot fast spin-echo (SSFSE) technique with an effective TE of 90-100 ms and without fat saturation. Benign and malignant lesions were compared for the presence of ureteral wall thickening and a signal intensity relative to the proximal ureteral wall. Statistically significant differences were found between benign and malignant lesions in both morphologic change (P 2 -weighted SSFSE technique without fat saturation can accurately distinguish between benign and malignant urinary obstructions. (author)

  13. Design of Slow and Fast Light Photonic Crystal Waveguides for Single-photon Emission Using a Bloch Mode Expansion Technique

    DEFF Research Database (Denmark)

    de Lasson, Jakob Rosenkrantz; Rigal, B.; Kapon, E.

    We design slow and fast light photonic crystal waveguides for single-photon emission using a Bloch mode expansion and scattering matrix technique. We propose slow light designs that increase the group index-waveguide mode volume ratio for larger Purcell enhancement, and address efficient slow-to-...

  14. Ultra-fast repair of single-strand breaks in DNA of. gamma. -irradiated Chinese hamster cells

    Energy Technology Data Exchange (ETDEWEB)

    Leontjeva, G A; Mantzighin, Yu A; Gaziev, A I [AN SSSR, Pushchino-na-Oke. Inst. Biologicheskoj Fiziki

    1976-12-01

    Studies of the effect of thermal treatment of Chinese hamster cells on sedimentation of DNA in the alkaline sucrose gradient showed that heating the cells to 68/sup 0/C for 15 min caused the same degradation as ..gamma..-irradiation with 5 to 7 krad at 37/sup 0/C. The inhibition of cellular repair enzymes by heating was therefore unacceptable. The process of ultra-fast repair is essentially determined by the DNA-ligase reaction, which is activated in the presence of Mg ions, and inhibited in mammalian cells in the presence of EDTA and pyrophosphate. Sedimentation profiles were therefore measured for the DNA of Chinese hamster cells ..gamma..-irradiated (5 krad) at 0/sup 0/C or 22/sup 0/C in the presence of Mg/sup + +/, or EDTA and pyrophosphate, and the results demonstrated ultra-fast repair only at 20 to 37/sup 0/C, in contrast to bacteria. A study was made of the temperature dependence of the activity of the DNA ligases isolated from E.coli and rabbit bone marrow. The NAD-dependent bacterial DNA ligase was active at temperatures from 0 to 40/sup 0/C, whereas ATP-dependent DNA ligase of mammals only showed activity in the range 15 to 40/sup 0/C. The differing temperature dependences of ultra-fast repair in bacterial and mammalian cells are in agreement with the temperature dependences of the activities of isolated enzymes, and the results suggest that the process of ultra-fast repair of single-strand breaks of DNA takes place in both bacterial and mammalian cells.

  15. Assessment of cartilage-dedicated sequences at ultra-high-field MRI: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0 T with respect to osteoarthritis-induced changes at the knee joint

    Energy Technology Data Exchange (ETDEWEB)

    Stahl, Robert [University of California, Musculoskeletal and Quantitative Imaging Group, Department of Radiology, San Francisco, CA (United States); University Hospitals - Campus Grosshadern, Ludwig Maximilians University of Munich, Department of Clinical Radiology, Munich (Germany); Krug, Roland; Zuo, Jin; Majumdar, Sharmila; Link, Thomas M. [University of California, Musculoskeletal and Quantitative Imaging Group, Department of Radiology, San Francisco, CA (United States); Kelley, Douglas A.C. [General Electrics Healthcare Technologies, San Francisco, CA (United States); Ma, C.B. [University of California, Department of Orthopedic Surgery, San Francisco, CA (United States)

    2009-08-15

    The objectives of the study were to optimize three cartilage-dedicated sequences for in vivo knee imaging at 7.0 T ultra-high-field (UHF) magnetic resonance imaging (MRI) and to compare imaging performance and diagnostic confidence concerning osteoarthritis (OA)-induced changes at 7.0 and 3.0 T MRI. Optimized MRI sequences for cartilage imaging at 3.0 T were tailored for 7.0 T: an intermediate-weighted fast spin-echo (IM-w FSE), a fast imaging employing steady-state acquisition (FIESTA) and a T1-weighted 3D high-spatial-resolution volumetric fat-suppressed spoiled gradient-echo (SPGR) sequence. Three healthy subjects and seven patients with mild OA were examined. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), diagnostic confidence in assessing cartilage abnormalities, and image quality were determined. Abnormalities were assessed with the whole organ magnetic resonance imaging score (WORMS). Focal cartilage lesions and bone marrow edema pattern (BMEP) were also quantified. At 7.0 T, SNR was increased (p<0.05) for all sequences. For the IM-w FSE sequence, limitations with the specific absorption rate (SAR) required modifications of the scan parameters yielding an incomplete coverage of the knee joint, extensive artifacts, and a less effective fat saturation. CNR and image quality were increased (p<0.05) for SPGR and FIESTA and decreased for IM-w FSE. Diagnostic confidence for cartilage lesions was highest (p<0.05) for FIESTA at 7.0 T. Evaluation of BMEP was decreased (p < 0.05) at 7.0 T due to limited performance of IM-w FSE. Gradient echo-based pulse sequences like SPGR and FIESTA are well suited for imaging at UHF which may improve early detection of cartilage lesions. However, UHF IM-w FSE sequences are less feasible for clinical use. (orig.)

  16. Assessment of cartilage-dedicated sequences at ultra-high-field MRI: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0 T with respect to osteoarthritis-induced changes at the knee joint

    International Nuclear Information System (INIS)

    Stahl, Robert; Krug, Roland; Zuo, Jin; Majumdar, Sharmila; Link, Thomas M.; Kelley, Douglas A.C.; Ma, C.B.

    2009-01-01

    The objectives of the study were to optimize three cartilage-dedicated sequences for in vivo knee imaging at 7.0 T ultra-high-field (UHF) magnetic resonance imaging (MRI) and to compare imaging performance and diagnostic confidence concerning osteoarthritis (OA)-induced changes at 7.0 and 3.0 T MRI. Optimized MRI sequences for cartilage imaging at 3.0 T were tailored for 7.0 T: an intermediate-weighted fast spin-echo (IM-w FSE), a fast imaging employing steady-state acquisition (FIESTA) and a T1-weighted 3D high-spatial-resolution volumetric fat-suppressed spoiled gradient-echo (SPGR) sequence. Three healthy subjects and seven patients with mild OA were examined. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), diagnostic confidence in assessing cartilage abnormalities, and image quality were determined. Abnormalities were assessed with the whole organ magnetic resonance imaging score (WORMS). Focal cartilage lesions and bone marrow edema pattern (BMEP) were also quantified. At 7.0 T, SNR was increased (p<0.05) for all sequences. For the IM-w FSE sequence, limitations with the specific absorption rate (SAR) required modifications of the scan parameters yielding an incomplete coverage of the knee joint, extensive artifacts, and a less effective fat saturation. CNR and image quality were increased (p<0.05) for SPGR and FIESTA and decreased for IM-w FSE. Diagnostic confidence for cartilage lesions was highest (p<0.05) for FIESTA at 7.0 T. Evaluation of BMEP was decreased (p < 0.05) at 7.0 T due to limited performance of IM-w FSE. Gradient echo-based pulse sequences like SPGR and FIESTA are well suited for imaging at UHF which may improve early detection of cartilage lesions. However, UHF IM-w FSE sequences are less feasible for clinical use. (orig.)

  17. Fast magnetization tunneling in tetranickel(II) single-molecule magnets.

    Science.gov (United States)

    Yang, En-Che; Wernsdorfer, Wolfgang; Zakharov, Lev N; Karaki, Yoshitomo; Yamaguchi, Akira; Isidro, Rose M; Lu, Guo-Di; Wilson, Samuel A; Rheingold, Arnold L; Ishimoto, Hidehiko; Hendrickson, David N

    2006-01-23

    A series of Ni(4) cubane complexes with the composition [Ni(hmp)(ROH)Cl](4) complexes 1-4 where R= -CH(3) (complex 1), -CH(2)CH(3) (complex 2), -CH(2)CH(2)(C(4)H(9)) (complex 3), -CH(2)CH(2)CH(2)(C(6)H(11)) (complex 4), hmp(-) is the anion of 2-hydroxymethylpyridine, t-Buhmp(-) is the anion of 4-tert-butyl-2-hydroxymethylpyridine, and dmb is 3,3-dimethyl-1-butanol] and [Ni(hmp)(dmb)Br](4) (complex 5) and [Ni(t-Buhmp)(dmb)Cl](4) (complex 6) were prepared. All six complexes were characterized by dc magnetic susceptibility data to be ferromagnetically coupled to give an S = 4 ground state with significant magnetoanisotropy (D approximately equal to -0.6 cm(-1)). Magnetization hysteresis measurements carried out on single crystals of complexes 1-6 establish the single-molecule magnet (SMM) behavior of these complexes. The exchange bias observed in the magnetization hysteresis loops of complexes 1 and 2 is dramatically decreased to zero in complex 3, where the bulky dmb ligand is employed. Fast tunneling of magnetization is observed for the high-symmetry (S(4) site symmetry) Ni(4) complexes in the crystal of complex 3, and the tunneling rate can even be enhanced by destroying the S(4) site symmetry, as is the case for complex 4, where there are two crystallographically different Ni(4) molecules, one with C(2) and the other with C(1) site symmetry. Magnetic ordering temperatures due to intermolecular dipolar and magnetic exchange interactions were determined by means of very low-temperature ac susceptibility measurements; complex 1 orders at 1100 mK, complex 3 at 290 mK, complex 4 at approximately 80 mK, and complex 6 at lower temperatures for those complexes with the bulkiest ligands.

  18. Ultra-fast optical manipulation of single proteins binding to the actin cytoskeleton

    Science.gov (United States)

    Capitanio, Marco; Gardini, Lucia; Pavone, Francesco Saverio

    2014-02-01

    In the last decade, forces and mechanical stresses acting on biological systems are emerging as regulatory factors essential for cell life. Emerging evidences indicate that factors such as applied forces or the rigidity of the extracellular matrix (ECM) determine the shape and function of cells and organisms1. Classically, the regulation of biological systems is described through a series of biochemical signals and enzymatic reactions, which direct the processes and cell fate. However, mechanotransduction, i.e. the conversion of mechanical forces into biochemical and biomolecular signals, is at the basis of many biological processes fundamental for the development and differentiation of cells, for their correct function and for the development of pathologies. We recently developed an in vitro system that allows the investigation of force-dependence of the interaction of proteins binding the actin cytoskeleton, at the single molecule level. Our system displays a delay of only ~10 μs between formation of the molecular bond and application of the force and is capable of detecting interactions as short as 100 μs. Our assay allows direct measurements of load-dependence of lifetimes of single molecular bonds and conformational changes of single proteins and molecular motors. We demonstrate our technique on molecular motors, using myosin II from fast skeletal muscle and on protein-DNA interaction, specifically on Lactose repressor (LacI). The apparatus is stabilized to less than 1 nm with both passive and active stabilization, allowing resolving specific binding regions along the actin filament and DNA molecule. Our technique extends single-molecule force-clamp spectroscopy to molecular complexes that have been inaccessible up to now, opening new perspectives for the investigation of the effects of forces on biological processes.

  19. Fast recognition of single molecules based on single-event photon statistics

    International Nuclear Information System (INIS)

    Dong Shuangli; Huang Tao; Liu Yuan; Wang Jun; Zhang Guofeng; Xiao Liantuan; Jia Suotang

    2007-01-01

    Mandel's Q parameter, which is determined from single-event photon statistics, provides an alternative way to recognize single molecules with fluorescence detection, other than the second-order correlation function. It is shown that the Q parameter of an assumed ideal double-molecule fluorescence with the same average photon number as that of the sample fluorescence can act as the criterion for single-molecule recognition. The influence of signal-to-background ratio and the error estimates for photon statistics are also presented. We have applied this method to ascertain single Cy5 dye molecules within hundreds of milliseconds

  20. The composing technique of fast and large scale nuclear data acquisition and control system with single chip microcomputers and PC computers

    International Nuclear Information System (INIS)

    Xu Zurun; Wu Shiying; Liu Haitao; Yao Yangsen; Wang Yingguan; Yang Chaowen

    1998-01-01

    The technique of employing single-chip microcomputers and PC computers to compose a fast and large scale nuclear data acquisition and control system was discussed in detail. The optimum composition mode of this kind of system, the acquisition and control circuit unit based on single-chip microcomputers, the real-time communication methods and the software composition under the Windows 3.2 were also described. One, two and three dimensional spectra measured by this system were demonstrated

  1. The composing technique of fast and large scale nuclear data acquisition and control system with single chip microcomputers and PC computers

    International Nuclear Information System (INIS)

    Xu Zurun; Wu Shiying; Liu Haitao; Yao Yangsen; Wang Yingguan; Yang Chaowen

    1997-01-01

    The technique of employing single-chip microcomputers and PC computers to compose a fast and large scale nuclear data acquisition and control system was discussed in detail. The optimum composition mode of this kind of system, the acquisition and control circuit unit based on single-chip microcomputers, the real-time communication methods and the software composition under the Windows 3.2 were also described. One, two and three dimensional spectra measured by this system were demonstrated

  2. Microchip electrophoresis-single wall carbon nanotube press-transferred electrodes for fast and reliable electrochemical sensing of melatonin and its precursors.

    Science.gov (United States)

    Gomez, Federico José Vicente; Martín, Aída; Silva, María Fernanda; Escarpa, Alberto

    2015-08-01

    In the current work, single-wall carbon nanotube press-transferred electrodes (SW-PTEs) were used for detection of melatonin (MT) and its precursors tryptophan (Trp) and serotonin (5-HT) on microchip electrophoresis (ME). SW-PTEs were simply fabricated by press transferring a filtered dispersion of single-wall carbon nanotubes on a nonconductive PMMA substrate, where single-wall carbon nanotubes act as exclusive transducers. The coupling of ME-SW-PTEs allowed the fast detection of MT, Trp, and 5-HT in less than 150 s with excellent analytical features. It exhibited an impressive antifouling performance with RSD values of ≤2 and ≤4% for migration times and peak heights, respectively (n = 12). In addition, sample analysis was also investigated by analysis of 5-HT, MT, and Trp in commercial samples obtaining excellent quantitative and reproducible recoveries with values of 96.2 ± 1.8%, 101.3 ± 0.2%, and 95.6 ± 1.2% for 5-HT, MT, and Trp, respectively. The current novel application reveals the analytical power of the press-transfer technology where the fast and reliable determination of MT and its precursors were performed directly on the nanoscale carbon nanotube detectors without the help of any other electrochemical transducer. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Formation of double-strand breaks in DNA of γ-irradiated bacteria depending on the function of fast repair processes of DNA single-strand breaks

    International Nuclear Information System (INIS)

    Petrov, S.I.; Gaziev, A.I.

    1980-01-01

    The formation of double-strand breaks in DNA of γ-irradiated ( 60 Co)Ex coli bacteria depending on the function of fast repair processes of DNA single-strand breaks, is investigated. The profiles of sedimentation of DNA Ex coli cells, irradiated at 0-2 deg C in the salt medium and in EDTA-borate buffer, are presented. It is shown that when irradiating cells in EDTA-borate buffer, the output of single- and double strand breaks in DNA is much higher than in the case of their irradiation in the minimum salt medium. The dependence of output of single-strand and double-strand breaks depending on the radiatier doze of E coli cells in the salt medium and EDTA-borate buffer, is studied. The supposition is made on the presence of a regulative interaction between the accumulation of DNA single-breaks and their repair with the formation of double-strand breaks. The functionating of fast and superfast repair processes considerably affects the formation of double-strand breaks in DNA of a bacterium cell. A considerable amount of double-breaks registered immediately after irradiation forms due to a close position of single-strand breaks on the opposite DNA strands

  4. Single-cell analysis by ICP-MS/MS as a fast tool for cellular bioavailability studies of arsenite.

    Science.gov (United States)

    Meyer, S; López-Serrano, A; Mitze, H; Jakubowski, N; Schwerdtle, T

    2018-01-24

    Single-cell inductively coupled plasma mass spectrometry (SC-ICP-MS) has become a powerful and fast tool to evaluate the elemental composition at a single-cell level. In this study, the cellular bioavailability of arsenite (incubation of 25 and 50 μM for 0-48 h) has been successfully assessed by SC-ICP-MS/MS for the first time directly after re-suspending the cells in water. This procedure avoids the normally arising cell membrane permeabilization caused by cell fixation methods (e.g. methanol fixation). The reliability and feasibility of this SC-ICP-MS/MS approach with a limit of detection of 0.35 fg per cell was validated by conventional bulk ICP-MS/MS analysis after cell digestion and parallel measurement of sulfur and phosphorus.

  5. Fast and quantitative differentiation of single-base mismatched DNA by initial reaction rate of catalytic hairpin assembly.

    Science.gov (United States)

    Li, Chenxi; Li, Yixin; Xu, Xiao; Wang, Xinyi; Chen, Yang; Yang, Xiaoda; Liu, Feng; Li, Na

    2014-10-15

    The widely used catalytic hairpin assembly (CHA) amplification strategy generally needs several hours to accomplish one measurement based on the prevailingly used maximum intensity detection mode, making it less practical for assays where high throughput or speed is desired. To make the best use of the kinetic specificity of toehold domain for circuit reaction initiation, we developed a mathematical model and proposed an initial reaction rate detection mode to quantitatively differentiate the single-base mismatch. Using the kinetic mode, assay time can be reduced substantially to 10 min for one measurement with the comparable sensitivity and single-base mismatch differentiating ability as were obtained by the maximum intensity detection mode. This initial reaction rate based approach not only provided a fast and quantitative differentiation of single-base mismatch, but also helped in-depth understanding of the CHA system, which will be beneficial to the design of highly sensitive and specific toehold-mediated hybridization reactions. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Dynamics of the single and double ionization of helium in fast proton collisions

    International Nuclear Information System (INIS)

    Doerner, R.; Schmidt-Boecking, H.

    1991-08-01

    A new experimental approach, designed to measure differential ionisation and electron capture cross sections for relativistic heavy ion beams, has been developed and was used to investigate dynamic mechanisms of Helium single and double ionisation in collisions with fast protons. Detailed insight into the dynamics of the ionisation process has been obtained. The experimental results prove, that the many-body momentum exchange between all particles involved, the projectile and target nucleus as well as the emitted electrons, has to be incorporated in order to correctly describe the ionisation collision dynamics. For the proton on Helium collision system the transverse momenta of projectile and recoil-ion were found to be of comparable magnitude only for very close collisions and large scattering angles above 1 mrad, which contribute less than 3% to the total ionisation cross section. (orig./HSI) [de

  7. Upgrading the Fast Calorimeter Simulation in ATLAS

    CERN Document Server

    Schaarschmidt, Jana; The ATLAS collaboration

    2017-01-01

    The tremendous need for simulated samples now and even more so in the future, encourage the development of fast simulation techniques. The Fast Calorimeter Simulation is a faster though less accurate alternative to the full calorimeter simulation with Geant4. It is based on parametrizing the longitudunal and lateral energy deposits of single particles in the ATLAS calorimeter. Principal component analysis and machine learning techniques are used to improve the performance and decrease the memory need compared to the current version of the ATLAS Fast Calorimeter Simulation. The parametrizations are expanded to cover very high energies and very forward detector regions, to increase the applicability of the tool. A prototype of this upgraded Fast Calorimeter Simulation has been developed and first validations with single particles show substantial improvements over the previous version.

  8. Effect of multiple plasmon excitation on single, double and multiple ionizations of C{sub 60} in collisions with fast highly charged Si ions

    Energy Technology Data Exchange (ETDEWEB)

    Kelkar, A H; Kadhane, U; Misra, D; Kumar, A; Tribedi, L C [Tata Institute of Fundamental Research, Colaba, Mumbai -5 (India)

    2007-06-28

    We have investigated the single and multiple ionizations of the C{sub 60} molecule in collisions with fast Si{sup q+} projectiles for various projectile charge states (q) between q = 6 and 14. The q-dependence of the ionization cross sections and their ratios is compared with the giant dipole plasmon resonance (GDPR) model. The excellent qualitative agreement with the model in case of single and double ionizations and also a reasonable agreement with the triple (and to some extent with quadruple) ionization (without evaporation) yields signify dominant contributions of the single-, double- and triple-plasmon excitations on the single- and multiple-ionization process.

  9. Evaluation of a fast single-photon avalanche photodiode for measurement of early transmitted photons through diffusive media.

    Science.gov (United States)

    Mu, Ying; Valim, Niksa; Niedre, Mark

    2013-06-15

    We tested the performance of a fast single-photon avalanche photodiode (SPAD) in measurement of early transmitted photons through diffusive media. In combination with a femtosecond titanium:sapphire laser, the overall instrument temporal response time was 59 ps. Using two experimental models, we showed that the SPAD allowed measurement of photon-density sensitivity functions that were approximately 65% narrower than the ungated continuous wave case at very early times. This exceeds the performance that we have previously achieved with photomultiplier-tube-based systems and approaches the theoretical maximum predicted by time-resolved Monte Carlo simulations.

  10. Fast reactor programme

    International Nuclear Information System (INIS)

    Plakman, J.C.

    1982-01-01

    This progress report summarizes the fast reactor research carried out by ECN during the period covering the year 1980. This research is mainly concerned with the cores of sodium-cooled breeders, in particular the SNR-300, and its related safety aspects. It comprises six items: A programme to determine relevant nuclear data of fission- and corrosion-products; A fuel performance programme comprising in-pile cladding failure experiments and a study of the consequences of loss-of-cooling and overpower; Basic research on fuel; Investigation of the changes in the mechanical properties of austenitic stainless steel DIN 1.4948 due to fast neutron doses, this material has been used in the manufacture of the reactor vessel and its internal components; Study of aerosols which could be formed at the time of a fast reactor accident and their progressive behaviour on leaking through cracks in the concrete containment; Studies on heat transfer in a sodium-cooled fast reactor core. As fast breeders operate at high power densities, an accurate knowledge of the heat transfer phenomena under single-phase and two-phase conditions is sought. (Auth.)

  11. Irradiation of the CLARO-CMOS chip, a fast ASIC for single-photon counting

    International Nuclear Information System (INIS)

    Andreotti, M.; Baldini, W.; Calabrese, R.; Carniti, P.; Cassina, L.; Cotta Ramusino, A.; Fiorini, M.; Giachero, A.; Gotti, C.; Luppi, E.; Maino, M.; Malaguti, R.; Pessina, G.; Tomassetti, L.

    2015-01-01

    The CLARO-CMOS is a prototype ASIC that allows fast photon counting with low power consumption, built in AMS 0.35 μm CMOS technology. It is intended to be used as a front-end readout for the upgraded LHCb RICH detectors. In this environment, assuming 10 years of operation at the nominal luminosity expected after the upgrade, the ASIC must withstand a total fluence of about 6×10 12 1 MeV n eq /cm 2 and a total ionising dose of 400 krad. Long term stability of the electronics front-end is essential and the effects of radiation damage on the CLARO-CMOS performance must be carefully studied. This paper describes results of multi-step irradiation tests with protons up to the dose of ~8 Mrad, including measurement of single event effects during irradiation and chip performance evaluation before and after each irradiation step

  12. Does fast-neutron radiotherapy merely reduce the radiation dose

    International Nuclear Information System (INIS)

    Ando, Koichi

    1984-01-01

    We examined whether fast-neutron radiotherapy is superior to low-LET radiotherpy by comparing the relationship between cell survival and tumor control probabilities after exposure of tumor-bearing (species) to the two modalities. Analysis based on TCD 50 assay and lung colony assay indicated that single dose of fast neutron achieved animal cures at higher survival rates than other radiation modalities including single and fractionated γ-ray doses, fractionated doses of fast neutron, and the mixed-beam scheme with a sequence of N-γ-γ-γ-N. We conclude that fast-neutron radiotherapy cured animal tumors with lower cell killing rates other radiation modalities. (author)

  13. Fast ℓ1-SPIRiT Compressed Sensing Parallel Imaging MRI: Scalable Parallel Implementation and Clinically Feasible Runtime

    Science.gov (United States)

    Murphy, Mark; Alley, Marcus; Demmel, James; Keutzer, Kurt; Vasanawala, Shreyas; Lustig, Michael

    2012-01-01

    We present ℓ1-SPIRiT, a simple algorithm for auto calibrating parallel imaging (acPI) and compressed sensing (CS) that permits an efficient implementation with clinically-feasible runtimes. We propose a CS objective function that minimizes cross-channel joint sparsity in the Wavelet domain. Our reconstruction minimizes this objective via iterative soft-thresholding, and integrates naturally with iterative Self-Consistent Parallel Imaging (SPIRiT). Like many iterative MRI reconstructions, ℓ1-SPIRiT’s image quality comes at a high computational cost. Excessively long runtimes are a barrier to the clinical use of any reconstruction approach, and thus we discuss our approach to efficiently parallelizing ℓ1-SPIRiT and to achieving clinically-feasible runtimes. We present parallelizations of ℓ1-SPIRiT for both multi-GPU systems and multi-core CPUs, and discuss the software optimization and parallelization decisions made in our implementation. The performance of these alternatives depends on the processor architecture, the size of the image matrix, and the number of parallel imaging channels. Fundamentally, achieving fast runtime requires the correct trade-off between cache usage and parallelization overheads. We demonstrate image quality via a case from our clinical experimentation, using a custom 3DFT Spoiled Gradient Echo (SPGR) sequence with up to 8× acceleration via poisson-disc undersampling in the two phase-encoded directions. PMID:22345529

  14. Imaging and histological features of central subchondral osteophytes in racehorses with metacarpophalangeal joint osteoarthritis.

    Science.gov (United States)

    Olive, J; D'Anjou, M A; Girard, C; Laverty, S; Theoret, C L

    2009-12-01

    Marginal osteophytes represent a well known component of osteoarthritis in man and animals. Conversely, central subchondral osteophytes (COs), which are commonly present in human knees with osteoarthritis, have not been reported in horses. To describe and compare computed radiography (CR), single-slice computed tomography (CT), 1.5 Tesla magnetic resonance imaging (MRI), and histological features of COs in equine metacarpophalangeal joints with macroscopic evidence of naturally-occurring osteoarthritis. MRI sequences (sagittal spoiled gradient recalled echo [SPGR] with fat saturation, sagittal T2-weighted fast spin echo with fat saturation [T2-FS], dorsal and transverse T1-weighted gradient-recalled echo [GRE], and sagittal T2*-weighted gradient echo with fast imaging employing steady state acquisition [FIESTA]), as well as transverse and reformatted sagittal CTI and 4 computed radiographic (CR) views of 20 paired metacarpophalangeal joints were acquired ex vivo. Following macroscopic evaluation, samples were harvested in predetermined sites of the metacarpal condyle for subsequent histology. The prevalence and detection level of COs was determined for each imaging modality. Abnormalities consistent with COs were clearly depicted on MRI, using the SPGR sequence, in 7/20 (35%) joints. They were identified as a focal hypointense protuberance from the subchondral plate into the cartilage, at the palmarodistal aspect (n=7) and/or at the very dorsal aspect (n=2) of the metacarpal condyle. COs were visible but less obvious in 5 of the 7 joints using FIESTA and reformatted sagittal CT, and were not identifiable on T2-FS, T1-GRE or CR. Microscopically, they consisted of dense bone protruding into the calcified cartilage and disrupting the tidemarks, and they were consistently associated with overlying cartilage defects. Subchondral osteophytes are a feature of osteoarthritis of equine metacarpophalangeal joints and they may be diagnosed using 1.5 Tesla MRI and CT. Central

  15. Active and fast charge-state switching of single NV centres in diamond by in-plane Al-Schottky junctions

    Directory of Open Access Journals (Sweden)

    Christoph Schreyvogel

    2016-11-01

    Full Text Available In this paper, we demonstrate an active and fast control of the charge state and hence of the optical and electronic properties of single and near-surface nitrogen-vacancy centres (NV centres in diamond. This active manipulation is achieved by using a two-dimensional Schottky-diode structure from diamond, i.e., by using aluminium as Schottky contact on a hydrogen terminated diamond surface. By changing the applied potential on the Schottky contact, we are able to actively switch single NV centres between all three charge states NV+, NV0 and NV− on a timescale of 10 to 100 ns, corresponding to a switching frequency of 10–100 MHz. This switching frequency is much higher than the hyperfine interaction frequency between an electron spin (of NV− and a nuclear spin (of 15N or 13C for example of 2.66 kHz. This high-frequency charge state switching with a planar diode structure would open the door for many quantum optical applications such as a quantum computer with single NVs for quantum information processing as well as single 13C atoms for long-lifetime storage of quantum information. Furthermore, a control of spectral emission properties of single NVs as a single photon emitters – embedded in photonic structures for example – can be realized which would be vital for quantum communication and cryptography.

  16. Self-Calibrating Wave-Encoded Variable-Density Single-Shot Fast Spin Echo Imaging.

    Science.gov (United States)

    Chen, Feiyu; Taviani, Valentina; Tamir, Jonathan I; Cheng, Joseph Y; Zhang, Tao; Song, Qiong; Hargreaves, Brian A; Pauly, John M; Vasanawala, Shreyas S

    2018-04-01

    It is highly desirable in clinical abdominal MR scans to accelerate single-shot fast spin echo (SSFSE) imaging and reduce blurring due to T 2 decay and partial-Fourier acquisition. To develop and investigate the clinical feasibility of wave-encoded variable-density SSFSE imaging for improved image quality and scan time reduction. Prospective controlled clinical trial. With Institutional Review Board approval and informed consent, the proposed method was assessed on 20 consecutive adult patients (10 male, 10 female, range, 24-84 years). A wave-encoded variable-density SSFSE sequence was developed for clinical 3.0T abdominal scans to enable high acceleration (3.5×) with full-Fourier acquisitions by: 1) introducing wave encoding with self-refocusing gradient waveforms to improve acquisition efficiency; 2) developing self-calibrated estimation of wave-encoding point-spread function and coil sensitivity to improve motion robustness; and 3) incorporating a parallel imaging and compressed sensing reconstruction to reconstruct highly accelerated datasets. Image quality was compared pairwise with standard Cartesian acquisition independently and blindly by two radiologists on a scale from -2 to 2 for noise, contrast, confidence, sharpness, and artifacts. The average ratio of scan time between these two approaches was also compared. A Wilcoxon signed-rank tests with a P value under 0.05 considered statistically significant. Wave-encoded variable-density SSFSE significantly reduced the perceived noise level and improved the sharpness of the abdominal wall and the kidneys compared with standard acquisition (mean scores 0.8, 1.2, and 0.8, respectively, P variable-density sampling SSFSE achieves improved image quality with clinically relevant echo time and reduced scan time, thus providing a fast and robust approach for clinical SSFSE imaging. 1 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2018;47:954-966. © 2017 International Society for Magnetic Resonance in Medicine.

  17. The Young-Feynman two-slits experiment with single electrons: Build-up of the interference pattern and arrival-time distribution using a fast-readout pixel detector

    Energy Technology Data Exchange (ETDEWEB)

    Frabboni, Stefano [Department of Physics, University of Modena and Reggio Emilia, Via G. Campi 213/a, 41125 Modena (Italy); CNR-Institute of Nanoscience-S3, Via G. Campi 213/a, 41125 Modena (Italy); Gabrielli, Alessandro [Department of Physics, University of Bologna, Viale B. Pichat 6/2, 40127 Bologna (Italy); INFN, Viale B. Pichat 6/2, 40127 Bologna (Italy); Carlo Gazzadi, Gian [CNR-Institute of Nanoscience-S3, Via G. Campi 213/a, 41125 Modena (Italy); Giorgi, Filippo [Department of Physics, University of Bologna, Viale B. Pichat 6/2, 40127 Bologna (Italy); INFN, Viale B. Pichat 6/2, 40127 Bologna (Italy); Matteucci, Giorgio [Department of Physics, University of Bologna, Viale B. Pichat 6/2, 40127 Bologna (Italy); Pozzi, Giulio, E-mail: giulio.pozzi@unibo.it [Department of Physics, University of Bologna, Viale B. Pichat 6/2, 40127 Bologna (Italy); Cesari, Nicola Semprini; Villa, Mauro; Zoccoli, Antonio [Department of Physics, University of Bologna, Viale B. Pichat 6/2, 40127 Bologna (Italy); INFN, Viale B. Pichat 6/2, 40127 Bologna (Italy)

    2012-05-15

    The two-slits experiment for single electrons has been carried out by inserting in a conventional transmission electron microscope a thick sample with two nano-slits fabricated by Focused Ion Beam technique and a fast recording system able to measure the electron arrival-time. The detector, designed for experiments in future colliders, is based on a custom CMOS chip equipped with a fast readout chain able to manage up to 10{sup 6} frames per second. In this way, high statistic samples of single electron events can be collected within a time interval short enough to measure the distribution of the electron arrival-times and to observe the build-up of the interference pattern. -- Highlights: Black-Right-Pointing-Pointer We present the first results obtained regarding the two-slits Young-Feynman experiment with single electrons. Black-Right-Pointing-Pointer We use two nano-slits fabricated by Focused Ion Beam technique. Black-Right-Pointing-Pointer We insert in the transmission electron microscope a detector, designed for experiments in future colliders. Black-Right-Pointing-Pointer We record the build-up of high statistic single electron interference patterns. Black-Right-Pointing-Pointer We measure the time distribution of electron arrivals.

  18. Anisotropy barrier reduction in fast-relaxing Mn12 single-molecule magnets

    Science.gov (United States)

    Hill, Stephen; Murugesu, Muralee; Christou, George

    2009-11-01

    An angle-swept high-frequency electron paramagnetic resonance (HFEPR) technique is described that facilitates efficient in situ alignment of single-crystal samples containing low-symmetry magnetic species such as single-molecule magnets (SMMs). This cavity-based technique involves recording HFEPR spectra at fixed frequency and field, while sweeping the applied field orientation. The method is applied to the study of a low-symmetry Jahn-Teller variant of the extensively studied spin S=10 Mn12 SMMs (e.g., Mn12 -acetate). The low-symmetry complex also exhibits SMM behavior, but with a significantly reduced effective barrier to magnetization reversal (Ueff≈43K) and, hence, faster relaxation at low temperature in comparison with the higher-symmetry species. Mn12 complexes that crystallize in lower symmetry structures exhibit a tendency for one or more of the Jahn-Teller axes associated with the MnIII atoms to be abnormally oriented, which is believed to be the cause of the faster relaxation. An extensive multi-high-frequency angle-swept and field-swept electron paramagnetic resonance study of [Mn12O12(O2CCH2But)16(H2O)4]ṡCH2Cl2ṡMeNO2 is presented in order to examine the influence of the abnormally oriented Jahn-Teller axis on the effective barrier to magnetization reversal. The reduction in the axial anisotropy, D , is found to be insufficient to account for the nearly 40% reduction in Ueff . However, the reduced symmetry of the Mn12 core gives rise to a very significant second-order transverse (rhombic) zero-field-splitting anisotropy, E≈D/6 . This, in turn, causes a significant mixing of spin projection states well below the top of the classical anisotropy barrier. Thus, magnetic quantum tunneling is the dominant factor contributing to the effective barrier reduction in fast relaxing Mn12 SMMs.

  19. A fast online hit verification method for the single ion hit system at GSI

    International Nuclear Information System (INIS)

    Du, G.; Fischer, B.; Barberet, P.; Heiss, M.

    2006-01-01

    For a single ion hit facility built to irradiate specific targets inside biological cells, it is necessary to prove that the ions hit the selected targets reliably because the ion hits usually cannot be seen. That ability is traditionally tested either indirectly by aiming at pre-etched tracks in a nuclear track detector or directly by making the ion tracks inside cells visible using a stain coupled to special proteins produced in response to ion hits. However, both methods are time consuming and hits can be verified only after the experiment. This means that targeting errors in the experiment cannot be corrected during the experiment. Therefore, we have developed a fast online hit verification method that measures the targeting accuracy electronically with a spatial resolution of ±1 μm before cell irradiation takes place. (authors)

  20. Network single-walled carbon nanotube biosensors for fast and highly sensitive detection of proteins

    International Nuclear Information System (INIS)

    Hu Pingan; Zhang Jia; Wen Zhenzhong; Zhang Can

    2011-01-01

    Detection of proteins is powerfully assayed in the diagnosis of diseases. A strategy for the development of an ultrahigh sensitivity biosensor based on a network single-walled carbon nanotube (SWNT) field-effect transistor (FET) has been demonstrated. Metallic SWNTs (m-SWNTs) in the network nanotube FET were selectively removed or cut via a carefully controlled procedure of electrical break-down (BD), and left non-conducting m-SWNTs which magnified the Schottky barrier (SB) area. This nanotube FET exhibited ultrahigh sensitivity and fast response to biomolecules. The lowest detection limit of 0.5 pM was achieved by exploiting streptavidin (SA) or a biotin/SA pair as the research model, and BD-treated nanotube biosensors had a 2 x 10 4 -fold lower minimum detectable concentration than the device without BD treatment. The response time is in the range of 0.3-3 min.

  1. Resolving Fast, Confined Diffusion in Bacteria with Image Correlation Spectroscopy.

    Science.gov (United States)

    Rowland, David J; Tuson, Hannah H; Biteen, Julie S

    2016-05-24

    By following single fluorescent molecules in a microscope, single-particle tracking (SPT) can measure diffusion and binding on the nanometer and millisecond scales. Still, although SPT can at its limits characterize the fastest biomolecules as they interact with subcellular environments, this measurement may require advanced illumination techniques such as stroboscopic illumination. Here, we address the challenge of measuring fast subcellular motion by instead analyzing single-molecule data with spatiotemporal image correlation spectroscopy (STICS) with a focus on measurements of confined motion. Our SPT and STICS analysis of simulations of the fast diffusion of confined molecules shows that image blur affects both STICS and SPT, and we find biased diffusion rate measurements for STICS analysis in the limits of fast diffusion and tight confinement due to fitting STICS correlation functions to a Gaussian approximation. However, we determine that with STICS, it is possible to correctly interpret the motion that blurs single-molecule images without advanced illumination techniques or fast cameras. In particular, we present a method to overcome the bias due to image blur by properly estimating the width of the correlation function by directly calculating the correlation function variance instead of using the typical Gaussian fitting procedure. Our simulation results are validated by applying the STICS method to experimental measurements of fast, confined motion: we measure the diffusion of cytosolic mMaple3 in living Escherichia coli cells at 25 frames/s under continuous illumination to illustrate the utility of STICS in an experimental parameter regime for which in-frame motion prevents SPT and tight confinement of fast diffusion precludes stroboscopic illumination. Overall, our application of STICS to freely diffusing cytosolic protein in small cells extends the utility of single-molecule experiments to the regime of fast confined diffusion without requiring advanced

  2. Uranium, Plutonium and Neptunium Co-recovery with Irradiated Fast Reactor MOX Fuel by Single Cycle Extraction Process

    Energy Technology Data Exchange (ETDEWEB)

    Masaumi Nakahara; Yuichi Sano; Kazunori Nomura; Tadahiro Washiya; Jun Komaki [Japan Atomic Energy Agency, 4-33 Muramatsu, Tokai-mura, Naka-gun, Ibaraki, 319-1194 (Japan)

    2008-07-01

    The behavior of Np in single cycle extraction processes using tri-n-butylphosphate (TBP) as an extractant for U, Pu and Np co-recovery was investigated as a part of NEXT (New Extraction System for Transuranium) process. Two approaches for Np co-recovery with U and Pu were carried out with irradiated MOX fuel from fast reactor 'JOYO'; one was the counter current experiment using a feed solution with a high HNO{sub 3} concentration and the other used a scrubbing solution with a high HNO{sub 3} concentration. Experimental results showed that the leakage of Np to the raffinate were 0.986 % and 5.96 % under the condition of high HNO{sub 3} concentration in the feed solution and scrubbing solution, respectively. The simulation results based on these experiments indicated that most of Np could be extracted and co-recovered with U and Pu, just by increasing HNO{sub 3} concentrations in the feed and scrubbing solution on the single cycle extraction process. (authors)

  3. The new ATLAS Fast Calorimeter Simulation

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00223142; The ATLAS collaboration

    2017-01-01

    Current and future need for large scale simulated samples motivate the development of reliable fast simulation techniques. The new Fast Calorimeter Simulation is an improved parameterized response of single particles in the ATLAS calorimeter that aims to accurately emulate the key features of the detailed calorimeter response as simulated with Geant4, yet approximately ten times faster. Principal component analysis and machine learning techniques are used to improve the performance and decrease the memory need compared to the current version of the ATLAS Fast Calorimeter Simulation. A prototype of this new Fast Calorimeter Simulation is in development and its integration into the ATLAS simulation infrastructure is ongoing.

  4. The new ATLAS Fast Calorimeter Simulation

    Science.gov (United States)

    Schaarschmidt, J.; ATLAS Collaboration

    2017-10-01

    Current and future need for large scale simulated samples motivate the development of reliable fast simulation techniques. The new Fast Calorimeter Simulation is an improved parameterized response of single particles in the ATLAS calorimeter that aims to accurately emulate the key features of the detailed calorimeter response as simulated with Geant4, yet approximately ten times faster. Principal component analysis and machine learning techniques are used to improve the performance and decrease the memory need compared to the current version of the ATLAS Fast Calorimeter Simulation. A prototype of this new Fast Calorimeter Simulation is in development and its integration into the ATLAS simulation infrastructure is ongoing.

  5. The age related slow and fast contributions to the overall changes in tibialis anterior contractile features disclosed by maximal single twitch scan.

    Science.gov (United States)

    Orizio, Claudio; Cogliati, Marta; Bissolotti, Luciano; Diemont, Bertrand; Gobbo, Massimiliano; Celichowski, Jan

    2016-01-01

    This work aimed to verify if maximal electrically evoked single twitch (STmax) scan discloses the relative functional weight of fast and slow small bundles of fibres (SBF) in determining the contractile features of tibialis anterior (TA) with ageing. SBFs were recruited by TA main motor point stimulation through 60 increasing levels of stimulation (LS): 20 stimuli at 2Hz for each LS. The lowest and highest LS provided the least ST and STmax, respectively. The scanned STmax was decomposed into individual SBF STs. They were identified when twitches from adjacent LS were significantly different and then subtracted from each other. Nine young (Y) and eleven old (O) subjects were investigated. Contraction time (CT) and STarea/STpeak (A/PT) were calculated per each SBF ST. 143 and 155 SBF STs were obtained in Y and O, respectively. Y: CT and A/PT range: 45-105ms and 67-183mNs/mN, respectively. Literature data set TA fast fibres at 34% so, from the arrays of CT and A/PT, 65ms and 100mNs/mN were identified as the upper limit for SBF fast ST classification. O: no SBF ST could be classified as fast. STmax scan reveals age-related changes in the relative contribution of fast and slow SBFs to the overall muscle mechanics. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Fast Detection of Airports on Remote Sensing Images with Single Shot MultiBox Detector

    Science.gov (United States)

    Xia, Fei; Li, HuiZhou

    2018-01-01

    This paper introduces a method for fast airport detection on remote sensing images (RSIs) using Single Shot MultiBox Detector (SSD). To our knowledge, this could be the first study which introduces an end-to-end detection model into airport detection on RSIs. Based on the common low-level features between natural images and RSIs, a convolution neural network trained on large amounts of natural images was transferred to tackle the airport detection problem with limited annotated data. To deal with the specific characteristics of RSIs, some related parameters in the SSD, such as the scales and layers, were modified for more accurate and rapider detection. The experiments show that the proposed method could achieve 83.5% Average Recall at 8 FPS on RSIs with the size of 1024*1024. In contrast to Faster R-CNN, an improvement on AP and speed could be obtained.

  7. Fast, reliable sexing of prosimian DNA

    DEFF Research Database (Denmark)

    Fredsted, Tina; Villesen, Palle

    2004-01-01

    to identify conserved regions in the amelogenin gene. Using these conserved regions, we can target species that have no sequence information. We designed a single, conserved primer pair that is useful for fast and reliable molecular sexing of prosimian primates. A single PCR yields two fragments in males...

  8. Investigation of interstitial atom ordering in energetically nonequivalent positions

    CERN Document Server

    Tashmetov, M Y; Mukhtarova, N N

    2002-01-01

    By X-ray and neutron diffraction methods the ordered structures of carbon atoms in complex carbide Ti sub 1 sub - sub x V sub x C sub 0 sub . sub 6 have been investigated. The one-phase samples have been prepared with cubic structure such as NaCl (space group Fm3m) by solid-phase vacuum sintering at 2070 K. The cubic ordered structure (sp.gr. Fd3d) with double parameter of the elementary cell in comparison with the initial one was formed after annealing the samples at 873 K (80 hours). The long-range order parameter (eta) is less than maximal in the investigated samples. It is established that at 980-1000 K the cubic ordered structure (sp.gr. Fd3m) transforms to the trigonal ordered structure (sp.gr. R3m; sp.gr. P3 sub 1 21). (author)

  9. Effervescent N-Acetylcysteine Tablets versus Oral Solution N-Acetylcysteine in Fasting Healthy Adults: An Open-Label, Randomized, Single-Dose, Crossover, Relative Bioavailability Study

    Directory of Open Access Journals (Sweden)

    Spencer C. Greene, MD, FACEP, FACMT

    2016-01-01

    Conclusions: Data from this study of a single dose of 11 g oral NAC demonstrated that effervescent NAC tablets and oral solution NAC met the regulatory criteria for bioequivalence in fasting healthy adult subjects. Effervescent NAC tablets appear to be a more palatable alternative for treatment of acetaminophen overdose. ClinicalTrials.gov identifier: NCT02723669.

  10. Kinematic MRI using short TR single shot fast spin echo (SSFSE) in evaluating swallowing

    Energy Technology Data Exchange (ETDEWEB)

    Isogai, Satoshi; Takehara, Yasuo; Isoda, Haruo; Kodaira, Nami; Masunaga, Hatsuko; Ozawa, Fukujirou; Kaneko, Masao [Hamamatsu Univ. School of Medicine, Shizuoka (Japan); Nozaki, Atsushi; Kabasawa, Hiroyuki

    1999-03-01

    The utility of short TR single shot fast spin echo (SSFSE) MR imaging for evaluating swallowing was determined. Five healthy volunteers underwent kinematic MR imaging of swallowing with a 1.5 T MR scanner using the short TR (300 ms) SSFSE sequence. Twenty phases of sagittal sections were acquired within 6 sec, where the temporal resolution was 300 ms. For oral contrast medium, we used prune yogurt juice with Fe added. The image contrast of short TR SSFSE was found to be somewhere like that of T1-weighted images. In all cases, both the buccal and pharyngeal stages of swallowing were successfully depicted. The Fe-added prune yogurt juice performed as a positive contrast medium and helped determine anatomical structures in the buccal stage. Short TR (300 ms) SSFSE was useful in evaluating swallowing. The combined use of Fe-added prune yogurt juice was helpful in enhancing the surface of the oropharynx. (author)

  11. Kinematic MRI using short TR single shot fast spin echo (SSFSE) in evaluating swallowing

    International Nuclear Information System (INIS)

    Isogai, Satoshi; Takehara, Yasuo; Isoda, Haruo; Kodaira, Nami; Masunaga, Hatsuko; Ozawa, Fukujirou; Kaneko, Masao; Nozaki, Atsushi; Kabasawa, Hiroyuki

    1999-01-01

    The utility of short TR single shot fast spin echo (SSFSE) MR imaging for evaluating swallowing was determined. Five healthy volunteers underwent kinematic MR imaging of swallowing with a 1.5 T MR scanner using the short TR (300 ms) SSFSE sequence. Twenty phases of sagittal sections were acquired within 6 sec, where the temporal resolution was 300 ms. For oral contrast medium, we used prune yogurt juice with Fe added. The image contrast of short TR SSFSE was found to be somewhere like that of T1-weighted images. In all cases, both the buccal and pharyngeal stages of swallowing were successfully depicted. The Fe-added prune yogurt juice performed as a positive contrast medium and helped determine anatomical structures in the buccal stage. Short TR (300 ms) SSFSE was useful in evaluating swallowing. The combined use of Fe-added prune yogurt juice was helpful in enhancing the surface of the oropharynx. (author)

  12. Complete momentum balance for single ionization of helium by fast ion impact: I. Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Moshammer, R.; Kollmus, H.; Unverzagt, M.; Schmidt-Boecking, H. [Frankfurt Univ. (Germany). Inst. fuer Kernphysik; Ullrich, J.; Schmitt, W. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Wood, C.J.; Olson, R.E. [Missouri Univ., Rolla, MO (United States). Dept. of Physics

    1997-02-01

    The collision dynamics of He single ionization by 3.6 MeV/u Se{sup 28+} impact was explored using the GSI-reaction microscope, a high resolution integrated multi electron - recoil-ion momentum spectrometer. The complete three particle final state momentum distribution (9 cartesian components p{sub i}) was imaged with a resolution of {Delta}p{sub i} {approx} {+-}0.1 a.u. by measuring the three momentum components of the emitted electron and the recoiling target-ion in coincidence. The projectile energy loss has been determined on a level of {Delta}E{sub p}/E{sub p} {approx} 10{sup -7} and projectile scattering angles as small as {Delta}{theta} {approx} 10{sup -7}rad became accessible. The experimental data which are compared with results of classical trajectory Monte-Carlo (CTMC) calculations reveal an unprecedented insight into the details of the electron emission and the collision dynamics for ionization of helium by fast heavy-ion impact. (orig.)

  13. Complete momentum balance for single ionization of helium by fast ion impact: I. Experiment

    International Nuclear Information System (INIS)

    Moshammer, R.; Kollmus, H.; Unverzagt, M.; Schmidt-Boecking, H.; Wood, C.J.; Olson, R.E.

    1997-02-01

    The collision dynamics of He single ionization by 3.6 MeV/u Se 28+ impact was explored using the GSI-reaction microscope, a high resolution integrated multi electron - recoil-ion momentum spectrometer. The complete three particle final state momentum distribution (9 cartesian components p i ) was imaged with a resolution of Δp i ∼ ±0.1 a.u. by measuring the three momentum components of the emitted electron and the recoiling target-ion in coincidence. The projectile energy loss has been determined on a level of ΔE p /E p ∼ 10 -7 and projectile scattering angles as small as Δθ ∼ 10 -7 rad became accessible. The experimental data which are compared with results of classical trajectory Monte-Carlo (CTMC) calculations reveal an unprecedented insight into the details of the electron emission and the collision dynamics for ionization of helium by fast heavy-ion impact. (orig.)

  14. Fast all-optical multistate flip-flop operation realized by a single self-sustained micro-ring laser memory cell

    International Nuclear Information System (INIS)

    Wang, Zhuoran; Yuan, Guohui

    2013-01-01

    We investigate all-optical multistate flip-flop operation realized by a single self-sustained micro-ring laser memory cell based on a time-domain multi-mode nonlinear model. Each state is written by the corresponding 100 ps-width input non-return-to-zero (NRZ) pulse carrying the directional and wavelength information, and the cell remains in the written state until another trigger arrives. The effects of key parameters including the detuning frequency and injection power ratio on the injection locking and flipping regions of different modes in both directions of the micro-ring device are studied. By optimizing the operation conditions, we simulate the minimal switching speed for each mode. The fast switching speed of less than 20 ps and up to ten mode flip-flop operation indicate that this single optical memory cell can support ten states at a data rate of at least 10 Gbps, which is particularly valuable for the realization of future all-optical networking and functional sub-system technology. (letter)

  15. A fast and reliable method for simultaneous waveform, amplitude and latency estimation of single-trial EEG/MEG data.

    Directory of Open Access Journals (Sweden)

    Wouter D Weeda

    Full Text Available The amplitude and latency of single-trial EEG/MEG signals may provide valuable information concerning human brain functioning. In this article we propose a new method to reliably estimate single-trial amplitude and latency of EEG/MEG signals. The advantages of the method are fourfold. First, no a-priori specified template function is required. Second, the method allows for multiple signals that may vary independently in amplitude and/or latency. Third, the method is less sensitive to noise as it models data with a parsimonious set of basis functions. Finally, the method is very fast since it is based on an iterative linear least squares algorithm. A simulation study shows that the method yields reliable estimates under different levels of latency variation and signal-to-noise ratioÕs. Furthermore, it shows that the existence of multiple signals can be correctly determined. An application to empirical data from a choice reaction time study indicates that the method describes these data accurately.

  16. The Adverse Effects and Treatment Results of Smoking Cessation Pharmacotherapy During Fasting/Non-Fasting State.

    Science.gov (United States)

    Iliaz, Sinem; Tural Onur, Seda; Uysal, Mehmet Atilla; Chousein, Efsun Gonca Uğur; Tanriverdi, Elif; Bagci, Belma Akbaba; Bahadir, Ayse; Hattatoglu, Didem Gorgun; Ortakoylu, Mediha Gonenc; Yurt, Sibel

    2017-07-03

    Cigarette smoking is one of the most common addictions worldwide. Muslim smokers reduce the number of cigarettes they smoke during Ramadan due to the long fasting hours. We aimed to share our experience in a smoking cessation clinic during Ramadan by analyzing the efficacy and adverse effects of once-daily dosing of bupropion or varenicline in a fasting group compared with conventional dosing in a non-fasting group. We analyzed 57 patients who attended our smoking cessation clinic during Ramadan of 2014 and 2015, and at least one follow-up visit. For the fasting patients, we prescribed bupropion or varenicline after dinner (once daily) as the maintenance therapy. We recorded demographic characteristics of the patients, fasting state, drugs taken for smoking cessation, and the dosage of the medication. At the first follow-up visit, adverse effects seen with the treatment were recorded. We conducted telephone interviews 6 months after the first visits of the patients to learn the current smoking status of the groups. Of the total 57 patients, 20 (35.1%) were fasting and 37 (64.9%) were not fasting. Fasting and non-fasting patients were similar for sex, age, smoking pack-years, marital status, educational status, and mean Fagerström scores (p >.05). Adverse effects and quit rates after 6 months of follow-up were similar between the fasting and non-fasting groups (p >.05). Although our sample size was small, we found no difference in the rates of adverse effects or smoking cessation using a single daily oral dose of bupropion or varenicline between a fasting group and a non-fasting group that received conventional dosing.

  17. Mechanism of enhancement of controllable secondary-electron emission from fast single electrons

    International Nuclear Information System (INIS)

    Lorikyan, M.P.; Kavalov, R.L.; Trofimchuk, N.N.; Arvanov, A.N.; Gavalyan, V.G.

    For porous KCl films (density approximately 2 percent, thickness 50-400 μm), the controllable secondary electron emission (CSEE) from fast single electrons with energies of 0.7-2 MeV was studied. An electric field E of approximately 10 4 -10 5 V/cm was set up inside the porous films and the emission curves anti sigma = f(E) and the energy spectra of the secondary electrons were measured. The mean emission coefficient anti sigma increases with increasing E, reaching a value of anti sigma approximately equal to 230. Internal enhancement of CSEE under the action of the E field is explained by a process similar to the Townsend semi-self-maintained discharge in gases. The mean free path L/sub e/ of the secondary electrons estimated on the basis of this mechanism of CSEE enhancement is in good agreement with the L/sub e/ value obtained independently from the energy spectra of the secondary electrons. The report examines the effect of the first critical potential U/sub il/ and of the electron affinity of the dielectric α on the formation of CSEE from a porous dielectric film. The possibility of using such films in particle detectors is discussed

  18. Comparison of respiratory-triggered 3-D fast spin-echo and single-shot fast spin-echo radial slab MR cholangiopancreatography images in children

    Energy Technology Data Exchange (ETDEWEB)

    Chavhan, Govind B.; Almehdar, Abeer; Gupta, Sumeet [The Hospital for Sick Children and University of Toronto, Department of Diagnostic Imaging, Toronto (Canada); Moineddin, Rahim [University of Toronto, Department of Family and Community Medicine, Toronto (Canada); Babyn, Paul S. [Royal University Hospital, Department of Medical Imaging, Saskatoon (Canada)

    2013-09-15

    The two most commonly performed magnetic resonance cholangiopancreatography (MRCP) sequences, 3-D fast spin-echo (3-D FSE) and single-shot fast spin-echo radial slabs (radial slabs), have not been compared in children. The purpose of this study was to compare 3-D FSE and radial slabs MRCP sequences on a 3-T scanner to determine their ability to show various segments of pancreaticobiliary tree and presence of artifacts in children. We reviewed 79 consecutive MRCPs performed in 74 children on a 3-T scanner. We noted visibility of major ducts on 3-D FSE and radial slabs. We noted the order of branching of ducts in the right and left hepatic ducts and the degree of visibility of the pancreatic duct. Statistical analysis was performed using McNemar and signed rank tests. There was no significant difference in the visibility of major bile ducts and the order of branching in the right hepatic lobe between sequences. A higher order of branching in the left lobe was seen on radial slabs than 3-D FSE (mean order of branching 2.82 versus 2.27; P-value = 0.0002). The visibility of pancreatic duct was better on radial slabs as compared to 3-D FSE (mean value of 1.53 vs. 0.90; P-value < 0.0001). 3-D FSE sequence was artifact-free in 25/79 (31.6%) MRCP exams as compared to radial slabs, which were artifact-free in 18/79 (22.8%) MRCP exams (P-value = 0.0001). There is no significant difference in the visibility of major bile ducts between 3-D FSE and radial slab MRCP sequences at 3-T in children. However, radial slab MRCP shows a higher order of branching in the left hepatic lobe and superior visibility of the pancreatic duct than 3-D FSE. (orig.)

  19. Sequential gadolinium-enhanced magnetic resonance angiography of the aortoiliac and the femoropopliteal arteries with repetitive administration of low-dose contrast agent

    International Nuclear Information System (INIS)

    Ito, Koichiro; Kumazaki, Tatsuo

    2000-01-01

    To obtain a wide-range contrast MR angiography in a single examination, we performed two sequential administrations of low-dose (0.08 mmol/kg) gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) with three dimensional inversion recovery prepared fast spoiled gradient recalled acquisition in the steady-state (3D IR-fast SPGR) sequence. Signal characteristics of the sequence were estimated by computed simulations and an in vitro study. A clinical study of 19 examinations was done with sequential MR angiography of the aortoiliac and femoropopliteal arteries. Great signal differences were observed between the high and low Gd concentrations. Higher Gd concentrations generated significantly stronger signals. Greater signals were produced at TIs of longer than 150 msec than at shorter than 100 msec. In the clinical study, the arteries were visualized with sufficient signals even with a small amount of contrast agent. Contrast-to-noise ratios between the arteries and surrounding skeletal muscles or fat tissues ranged from 10.5±9.6 to 4.7±2.2 and 6.6±2.8 to -3.1±11.2, respectively. No venous enhancement was found with diluted contrast agent on the second MR angiography. Two consecutive contrast MR angiographies can be obtained with repetitive administration of low-dose contrast agent. (author)

  20. Sequential gadolinium-enhanced magnetic resonance angiography of the aortoiliac and the femoropopliteal arteries with repetitive administration of low-dose contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Koichiro [Nippon Medical School, Inba, Chiba (Japan). Chiba Hokusoh Hospital; Kumazaki, Tatsuo

    2000-12-01

    To obtain a wide-range contrast MR angiography in a single examination, we performed two sequential administrations of low-dose (0.08 mmol/kg) gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) with three dimensional inversion recovery prepared fast spoiled gradient recalled acquisition in the steady-state (3D IR-fast SPGR) sequence. Signal characteristics of the sequence were estimated by computed simulations and an in vitro study. A clinical study of 19 examinations was done with sequential MR angiography of the aortoiliac and femoropopliteal arteries. Great signal differences were observed between the high and low Gd concentrations. Higher Gd concentrations generated significantly stronger signals. Greater signals were produced at TIs of longer than 150 msec than at shorter than 100 msec. In the clinical study, the arteries were visualized with sufficient signals even with a small amount of contrast agent. Contrast-to-noise ratios between the arteries and surrounding skeletal muscles or fat tissues ranged from 10.5{+-}9.6 to 4.7{+-}2.2 and 6.6{+-}2.8 to -3.1{+-}11.2, respectively. No venous enhancement was found with diluted contrast agent on the second MR angiography. Two consecutive contrast MR angiographies can be obtained with repetitive administration of low-dose contrast agent. (author)

  1. Detection of adrenocorticotropin-secreting pituitary adenomas by magnetic resonance imaging in children and adolescents with cushing disease.

    Science.gov (United States)

    Batista, Dalia; Courkoutsakis, Nickolas A; Oldfield, Edward H; Griffin, Kurt J; Keil, Meg; Patronas, Nickolas J; Stratakis, Constantine A

    2005-09-01

    We recently showed that pre- and postcontrast spoiled gradient-recalled acquisition in the steady-state (SPGR) was superior to conventional pre- and postcontrast T-1 weighted spin echo (SE) acquisition magnetic resonance imaging (MRI) for the diagnostic evaluation of pituitary tumors in adult patients. The present investigation assessed the use of SPGR vs. SE-MRI in the diagnostic evaluation of ACTH-secreting tumors in children and adolescents with Cushing disease. Data were analyzed retrospectively from a series of patients seen over 7 yr (1997-2004). The setting for this study was a tertiary care referral center. Thirty children with Cushing disease (13 females and 17 males with a mean age of 12 +/- 3 yr) were studied. Imaging results were compared with surgical and pathological findings and the clinical outcome. Twenty-eight patients had microadenomas, and two had macroadenomas; the latter were identified by both MRI techniques. Precontrast SE and SPGR-MRI identified four and six of the microadenomas, respectively. Postcontrast SPGR-MRI identified the location of the tumor in 18 of 28 patients, whereas postcontrast SE-MRI identified the location and accurately estimated the size of the tumor in only five patients (P children and adolescents with Cushing disease. Postcontrast SPGR-MRI was superior to SE-MRI and should be used in addition to conventional SE-MRI in the pituitary evaluation of children and adolescents with suspected Cushing disease.

  2. A single camera photogrammetry system for multi-angle fast localization of EEG electrodes.

    Science.gov (United States)

    Qian, Shuo; Sheng, Yang

    2011-11-01

    Photogrammetry has become an effective method for the determination of electroencephalography (EEG) electrode positions in three dimensions (3D). Capturing multi-angle images of the electrodes on the head is a fundamental objective in the design of photogrammetry system for EEG localization. Methods in previous studies are all based on the use of either a rotating camera or multiple cameras, which are time-consuming or not cost-effective. This study aims to present a novel photogrammetry system that can realize simultaneous acquisition of multi-angle head images in a single camera position. Aligning two planar mirrors with the angle of 51.4°, seven views of the head with 25 electrodes are captured simultaneously by the digital camera placed in front of them. A complete set of algorithms for electrode recognition, matching, and 3D reconstruction is developed. It is found that the elapsed time of the whole localization procedure is about 3 min, and camera calibration computation takes about 1 min, after the measurement of calibration points. The positioning accuracy with the maximum error of 1.19 mm is acceptable. Experimental results demonstrate that the proposed system provides a fast and cost-effective method for the EEG positioning.

  3. Development of fast ignition integrated interconnecting code (FI3) for fast ignition scheme

    International Nuclear Information System (INIS)

    Nagatomo, H.; Johzaki, T.; Mima, K.; Sunahara, A.; Nishihara, K.; Izawa, Y.; Sakagami, H.; Nakao, Y.; Yokota, T.; Taguchi, T.

    2005-01-01

    The numerical simulation plays an important role in estimating the feasibility and performance of the fast ignition. There are two key issues in numerical analysis for the fast ignition. One is the controlling the implosion dynamics to form a high density core plasma in non-spherical implosion, and the other is heating core plasma efficiency by the short pulse high intense laser. From initial laser irradiation to final fusion burning, all the physics are coupling strongly in any phase, and they must be solved consistently in computational simulation. However, in general, it is impossible to simulate laser plasma interaction and radiation hydrodynamics in a single computational code, without any numerical dissipation, special assumption or conditional treatment. Recently, we have developed 'Fast Ignition Integrated Interconnecting code' (FI 3 ) which consists of collective Particle-in-Cell code, Relativistic Fokker-Planck hydro code, and 2-dimensional radiation hydrodynamics code. And those codes are connecting with each other in data-flow bases. In this paper, we will present detail feature of the FI 3 code, and numerical results of whole process of fast ignition. (author)

  4. Fast-track video-assisted thoracoscopic surgery

    DEFF Research Database (Denmark)

    Holbek, Bo Laksafoss; Petersen, René Horsleben; Kehlet, Henrik

    2016-01-01

    Objectives To provide a short overview of fast-track video-assisted thoracoscopic surgery (VATS) and to identify areas requiring further research. Design A literature search was made using key words including: fast-track, enhanced recovery, video-assisted thoracoscopic surgery, robot......-assisted thoracoscopic surgery (RATS), robotic, thoracotomy, single-incision, uniportal, natural orifice transluminal endoscopic surgery (NOTES), chest tube, air-leak, digital drainage, pain management, analgesia, perioperative management, anaesthesia and non-intubated. References from articles were screened for further...

  5. Fast beam radiofrequency spectroscopy

    International Nuclear Information System (INIS)

    Pipkin, F.M.

    1983-01-01

    The combination of a fast atom or ion beam derived from a small accelerator with radiofrequency spectroscopy methods provides a powerful method for measuring the fine structure of atomic and molecular systems. The fast beam makes possible measurements in which two separated oscillatory fields are used to obtain resonance lines whose widths are less than the natural line width due to the lifetimes of the states. The separated oscillatory field lines have, in addition, a number of features which make possible measurements with greater precision and less sensitivity to systematic errors. The fast beam also makes accessible multiple photon radiofrequency transitions whose line width is intrinsically narrower than that of the single photon transitions and which offer great potential for high precision measurements. This report focuses on the techniques and their promise. Recent measurements of the fine structure of H and He + are used as illustrations

  6. Single- and two-phase flow modeling for coupled neutronics / thermal-hydraulics transient analysis of advanced sodium-cooled fast reactors

    International Nuclear Information System (INIS)

    Chenu, A.

    2011-10-01

    Nuclear power is nowadays in the front rank as regards helping to meet the growing worldwide energy demand while avoiding an excessive increase in greenhouse gas emissions. However, the operating nuclear power plants are mainly thermal-neutron reactors and, as such, can not be maintained on the basis of the currently identified uranium resources beyond one century at the present consumption rate. Sustainability of nuclear power thus involves closure of the fuel cycle through breeding. With a uranium-based fuel, breeding can only be achieved using a fast-neutron reactor. Sodium-cooled fast reactor (SFR) technology benefits from 400 reactor-years of accumulated experience and is thus a prime candidate for the implementation of so-called Generation-IV nuclear energy systems. In this context, the safety demonstration of SFRs remains a major Research and Development related issue. The current research aims at the development of a computational tool for the in-depth understanding of SFR core behaviour during accidental transients, particularly those including boiling of the coolant. An accurate modelling of the core physics during such transients requires the coupling between 3D neutron kinetics and thermal-hydraulics in the core, to account for the strong interactions between the two-phase coolant flow and power variations caused by the sodium void effect. The present study is specifically focused upon models for the representation of sodium two-phase flow. The extension of the thermal-hydraulics TRACE code, previously limited to the simulation of single-phase sodium flow, has been carried out through the implementation of equations-of-state and closure relations specific to sodium. The different correlations have then been implemented as options. From the validation study carried out, it has been possible to recommend a set of models which provide satisfactory results, while considering annular flow as the dominant regime up to dryout and a smooth breakdown of the

  7. Magnetic Resonance angiography with bolus contrast agent in abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Di Cesare, E.; Cerone, G.; Giordano, A.V.; Marsili, L.; Barile, A.; Michelini, O.; Masciocchi, C.; Spartera, C.

    2000-01-01

    Purpose of this paper is to investigate the potentials of 3D breath-hold contrast-enhanced Magnetic Resonance Angiography (MRA) in the diagnosis, follow-up and treatment planning of abdominal aortic aneurysms. Twenty-four patients with infrarenal aortic aneurysm underwent MRA. It was used a 1.5 T unit (GE Horizon, Echospeed 8.2), a phased array surface coil and 3D Fast SPGR T1-weighted sequences acquired on the coronal plane during patient breath-hold and after contrast agent i.v. administration. A bolus-test was done before angiography to optimize imaging delay time. After 3D MRA a Fast-SPGR T1-weighted sequence was acquired on the axial plane. The 3D MRA source images were processed with the MIP algorithm. Qualitative and quantitative analyses were carried out. Helical CT was performed in 6 cases and DSA in 7 cases. Surgery was the reference standard in 15 patients. MRA depicted aneurysm thrombosis in 22 cases, carrefour involvement in 18 cases and iliac arteries involvement in 3 cases. Accessory renal arteries were shown in 4 cases; iliac artery stenosis was associated in 5 cases. There was agreement between MR and Helical CT and DSA findings: surgery confirmed MRA results in 15/15 cases. 3D contrast-enhanced MRA can be considered the method of choice in the follow-up and treatment planning of abdominal aortic aneurysms, because it provides both angiographic and tomographic images: this allows to obtain more information, noninvasively and without the use of ionizing radiations [it

  8. An equilibrium-point model for fast, single-joint movement: I. Emergence of strategy-dependent EMG patterns.

    Science.gov (United States)

    Latash, M L; Gottlieb, G L

    1991-09-01

    We describe a model for the regulation of fast, single-joint movements, based on the equilibrium-point hypothesis. Limb movement follows constant rate shifts of independently regulated neuromuscular variables. The independently regulated variables are tentatively identified as thresholds of a length sensitive reflex for each of the participating muscles. We use the model to predict EMG patterns associated with changes in the conditions of movement execution, specifically, changes in movement times, velocities, amplitudes, and moments of limb inertia. The approach provides a theoretical neural framework for the dual-strategy hypothesis, which considers certain movements to be results of one of two basic, speed-sensitive or speed-insensitive strategies. This model is advanced as an alternative to pattern-imposing models based on explicit regulation of timing and amplitudes of signals that are explicitly manifest in the EMG patterns.

  9. Accidents and transients analyses of a super fast reactor with single flow pass core

    International Nuclear Information System (INIS)

    Sutanto,; Oka, Yoshiaki

    2014-01-01

    Highlights: • Safety analysis of a Super FR with single flow pass core is conducted. • Loss of feed water flow leads to a direct effect on the loss of fuel channel flow. • The core pressure is sensitive to LOCA accidents due to the direct effect. • Small LOCA introduces a critical break. • The safety criteria for all selected events are satisfied. - Abstract: The supercritical water cooled fast reactor with single flow pass core has been designed to simplify refueling and the structures of upper and lower mixing plenums. To evaluate the safety performance, safety analysis has been conducted with regard to LOCA and non-LOCA accidents including transient events. Safety analysis results show that the safety criteria are satisfied for all selected events. The total loss of feed water flow is the most important accident which the maximum cladding surface temperature (MCST) is high due to a direct effect of the accident on the total loss of flow in all fuel assemblies. However, actuation of the ADS can mitigate the accident. Small LOCA also introduces a critical break at 7.8% break which results high MCST at BOC because the scram and ADS are not actuated. Early ADS actuation is effective to mitigate the accident. In large LOCA, 100% break LOCA results a high MCST of flooding phase at BOC due to high power peaking at the bottom part. Use of high injection flow rate by 2 LPCI units is effective to decrease the MCST

  10. Features of the structural states of KNbO{sub 3} single crystals before and after fast-neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Stash, A. I., E-mail: astas@yandex.ru; Ivanov, S. A.; Stefanovich, S. Yu.; Mosunov, A. V.; Boyko, V. M.; Ermakov, V. S.; Korulin, A. V.; Kalyukanov, A. I. [State Scientific Center of the Russian Federation Karpov Institute of Physical Chemistry (Russian Federation)

    2017-01-15

    Neutron irradiation is a unique tool for forming new structural states of ferroelectrics, which cannot be obtained by conventional methods. The inf luence of the irradiation by two doses of fast neutrons (F = 1 × 10{sup 17} and 3 × 10{sup 17} cm{sup –2}) on the structure and properties of KNbO{sub 3} single crystals has been considered for the first time. The developed method for taking into account the experimental correction to the diffuse scattering has been used to analyze the structural changes occurring in KNbO{sub 3} samples at T = 295 K and their correlations with the behavior of dielectric and nonlinear optical characteristics. The irradiation to the aforementioned doses retains the KNbO{sub 3} polar structure, shifting Т{sub Ð}¡ to lower temperatures and significantly affecting only the thermal parameters and microstructure of single crystals. Neutron irradiation with small atomic displacements provides a structure similar to the high-temperature modification of an unirradiated KNbO{sub 3} crystal.

  11. The integral fast reactor

    International Nuclear Information System (INIS)

    Till, C.E.

    1987-01-01

    On April 3rd, 1986, two dramatic demonstrations of the inherent capability of sodium-cooled fast reactors to survive unprotected loss of cooling accidents were carried out on the experimental sodium-cooled power reactor, EBR-II, on the Idaho site of Argonne National Laboratory. Transients potentially of the most serious kind, one an unprotected loss of flow, the other an unprotected loss of heat sink, both initiated from full power. In both cases the reactor quietly shut itself down, without damage of any kind. These tests were a part of the on-going development program at Argonne to develop an advanced reactor with significant new inherent safety characteristics. Called the Integral Fast Reactor, or IFR, the basic thrust is to develop everything that is needed for a complete nuclear power system - reactor, closed fuel cycle, and waste processing - as a single optimized entity, and, for simplicity in concept, as an integral part of a single plant. The particular selection of reactor materials emphasizes inherent safety characteristics and also makes possible a simplified closed fuel cycle and waste process improvements

  12. Fast Estimation of Epicentral Distance and Magnitude from a Single Three Component Seismic Station Using Machine Learning Techniques

    Science.gov (United States)

    Ochoa Gutierrez, L. H.; Niño, L. F.; Vargas-Jimenez, C. A.

    2013-05-01

    To minimize adverse effects originated by high magnitude earthquakes, early warning has become a powerful tool to anticipate a seismic wave arrival to an specific location, bringing opportune information to people and government agencies to initiate a fast response. To do this, a very fast and accurate characterization of the event must be done but this process is often made using seismograms recorded in at least four stations where processing time is usually greater than the wave arrival time to the interest area, mainly in seismological coarse networks. A faster process can be done if only one three component seismic station, the closest unsaturated station with respect to the epicenter, is used. Here, we present a Support Vector Regression algorithm which calculates Magnitude and Epicentral Distance using only five seconds of signal since P wave onset. This algorithm was trained with 36 records of historical earthquakes, where the input included regression parameters of an exponential function estimated by least squares, of the waveform envelope and the maximum value of the observed waveform for each component in a single station. A ten-fold Cross Validation was applied for a Normalized Polynomial Kernel obtaining the mean absolute error for different exponents and complexity parameters. The Magnitude could be estimated with 0.16 units of mean absolute error and the distance with an error of 7.5 km for distances within 60 to 120 km. This kind of algorithm is easy to implement in hardware and can be used directly in the field seismological sensor to make the broadcast of estimations of these values possible to generate fast decisions at seismological control centers, increasing the possibility of having an effective reaction.

  13. Fast-ion losses induced by ACs and TAEs in the ASDEX Upgrade tokamak

    International Nuclear Information System (INIS)

    GarcIa-Munoz, M.; Hicks, N.; Classen, I.G.J.; Bilato, R.; Bobkov, V.; Brambilla, M.; Bruedgam, M.; Fahrbach, H.-U.; Igochine, V.; Maraschek, M.; Sassenberg, K.; Van Voornveld, R.; Jaemsae, S.

    2010-01-01

    The phase-space of convective and diffusive fast-ion losses induced by shear Alfven eigenmodes has been characterized in the ASDEX Upgrade tokamak. Time-resolved energy and pitch-angle measurements of fast-ion losses correlated in frequency and phase with toroidal Alfven eigenmodes (TAEs) and Alfven cascades (ACs) have allowed to identify both loss mechanisms. While single ACs and TAEs eject resonant fast-ions in a convective process, the overlapping of AC and TAE spatial structures leads to a large fast-ion diffusion and loss. The threshold for diffusive fast-ion losses depends on the ion energy (gyroradius). Diffusive fast-ion losses with gyroradius ∼70 mm have been observed with a single TAE for local radial displacements of the magnetic field lines larger than ∼2 mm. Multiple frequency chirping ACs cause an enhancement of the diffusive losses. The ACs and TAEs radial structures have been reconstructed by means of cross-correlation techniques between the fast-ion loss detector and the electron cyclotron emission radiometer.

  14. Sampling system for fast single pulses; Realisation d'un dispositif d'echantillonnage d'un signal bref unique

    Energy Technology Data Exchange (ETDEWEB)

    Zenatti, D [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    Development of a device for the enlargement of the domain of application of classical oscilloscopes to the observation of fast single pulses by application of the sampling principle. Its principal characteristics are: Bandwidth of 700 MHz; Maximum sensibility of 50 mV; Maximum amplitude of input signal of {+-} 1 V; Number of samples of 16; Samples separation of 0,2 ns. (author) [French] Realisation d'un dispositif permettant d'elargir le domaine d'utilisation des oscilloscopes classiques en appliquant le principe de l'echantillonnage a l'observation d'un signal bref unique. Les principales caracteristiques sont les suivantes: Bande passante de 700 MHz; Sensibilite maximale de 50 mV; Amplitude maximale du signal a echantillonner de {+-} 1 V; Nombre de points d'echantillonnage de 16; Pas d'echantillonnage de 0,2 ns. (auteur)

  15. The ELETTRA fast magnets

    International Nuclear Information System (INIS)

    Tommasini, D.

    1992-01-01

    The design of the fast magnets to be used to inject the electron beam into the 2 GeV storage ring Elettra is presented and discussed. Injection makes use of two types of fast magnets: the septa and the kickers. There are two identical septa magnets of the so called 'eddy current' type, which will be housed in a vacuum tank. The orbit bump is generated by four identical kicker magnets symmetrically placed around the mid-point of a single straight section: they will be in air with an internal vacuum chamber. Extensive electric and magnetic tests have been performed on prototypes, and the relevant results are presented and discussed. (author) 6 refs.; 6 figs.; 2 tabs

  16. Coupled hydro-neutronic calculations for fast burst reactor accidents

    International Nuclear Information System (INIS)

    Paternoster, R.; Kimpland, R.; Jaegers, P.; McGhee, J.

    1994-01-01

    Methods are described for determining the fully coupled neutronic/hydrodynamic response of fast burst reactors (FBR) under disruptive accident conditions. Two code systems, PAD (1 -D Lagrangian) and NIKE-PAGOSA (3-D Eulerian) were used to accomplish this. This is in contrast to the typical methodology that computes these responses by either single point kinetics or in a decoupled manner. This methodology is enabled by the use of modem supercomputers (CM-200). Two examples of this capability are presented: an unreflected metal fast burst assembly, and a reflected fast burst assembly typical of the Skua or SPR-III class of fast burst reactor

  17. Fast-track rehabilitation in elective colorectal surgery patients: a prospective clinical and immunological single-centre study.

    Science.gov (United States)

    Wichmann, Matthias W; Eben, Ricarda; Angele, Martin K; Brandenburg, Franzis; Goetz, Alwin E; Jauch, Karl-Walter

    2007-07-01

    Recent clinical data indicate that fast-track surgery (multimodal rehabilitation) leads to shorter postoperative length of hospital stay, faster recovery of gastrointestinal function as well as reduced morbidity and mortality rates. To date, no study has focused on the effects of fast-track surgery on postoperative immune function. This study was initiated to determine whether fast-track rehabilitation results in improved clinical and immunological outcome of patients undergoing colorectal surgery. Forty patients underwent either conventional or fast-track rehabilitation after colorectal surgery. In addition to clinical parameters (return of gastrointestinal function, food intake, pain score, complication rates and postoperative length of stay), we determined parameters of perioperative immunity by flow cytometry (lymphocyte subgroups) and enzyme-linked immunosorbent assay (interleukin-6). Our findings indicate a better-preserved cell-mediated immune function (T cells, T-helper cells, natural killer cells) after fast-track rehabilitation, whereas the pro-inflammatory response (C-reactive protein, interleukin-6) was unchanged in both study groups. Furthermore, we detected a significantly faster return of gastrointestinal function (first bowel movement P<0.001, food intake P<0.05), significantly reduced pain scores in the postoperative course (P < 0.05) and a significantly shorter length of postoperative stay (P<0.001) in patients undergoing fast-track rehabilitation. Fast-track rehabilitation after colorectal surgery results in better-preserved cell-mediated immunity when compared with conventional postoperative care. Furthermore, patients undergoing fast-track rehabilitation suffer from less pain and have a faster return of gastrointestinal function in the postoperative course. In addition, postoperative length of hospital stay was significantly shorter in fast-track patients.

  18. Fasting launches CRTC to facilitate long-term memory formation in Drosophila.

    Science.gov (United States)

    Hirano, Yukinori; Masuda, Tomoko; Naganos, Shintaro; Matsuno, Motomi; Ueno, Kohei; Miyashita, Tomoyuki; Horiuchi, Junjiro; Saitoe, Minoru

    2013-01-25

    Canonical aversive long-term memory (LTM) formation in Drosophila requires multiple spaced trainings, whereas appetitive LTM can be formed after a single training. Appetitive LTM requires fasting prior to training, which increases motivation for food intake. However, we found that fasting facilitated LTM formation in general; aversive LTM formation also occurred after single-cycle training when mild fasting was applied before training. Both fasting-dependent LTM (fLTM) and spaced training-dependent LTM (spLTM) required protein synthesis and cyclic adenosine monophosphate response element-binding protein (CREB) activity. However, spLTM required CREB activity in two neural populations--mushroom body and DAL neurons--whereas fLTM required CREB activity only in mushroom body neurons. fLTM uses the CREB coactivator CRTC, whereas spLTM uses the coactivator CBP. Thus, flies use distinct LTM machinery depending on their hunger state.

  19. Control of slow-to-fast light and single-to-double optomechanically induced transparency in a compound resonator system: A theoretical approach

    Science.gov (United States)

    Ziauddin; Rahman, Mujeeb ur; Ahmad, Iftikhar; Qamar, Sajid

    2017-10-01

    The transmission characteristics of probe light field is investigated theoretically in a compound system of two coupled resonators. The proposed system consisted of two high-Q Fabry-Perot resonators in which one of the resonators is optomechanical. Optomechanically induced transparency (OMIT), having relatively large window, is noticed via strong coupling between the two resonators. We investigate tunable switching from single to double OMIT by increasing amplitude of the pump field. We notice that, control of slow and fast light can be obtained via the coupling strength between the two resonators.

  20. Fast pulse beam generation systems for electron accelerators

    International Nuclear Information System (INIS)

    Koontz, R.F.

    1977-01-01

    The fast pulse beam generation system to supply the SLAC storage ring, SPEAR, by the two one nanosecond bunch electron beam pulses is described. Generation of these pulses is accomplished with a combination of a fast pulsed grided gun and a synchronized transverse beam chopper. Fast gun based on spherical cathode-grid assembly has output current up to 2As. Fast pulse amplifier system can handle trains of short pulses with repetition rates up to 40 MHz during the 1.6 μs normal accelerating time. Chopping deflector system consists of a resonant coaxial line with the deflecting plates. The resonator frequency is 39.667 MHz. A schematic diagram of the resonant system is shown. The fast beam pickup system has a one hundred picosecond rise time overrall. Fast beam generation and chopper systems permit to generate almost any short or single bunch beam profile needed for experiments

  1. Comparison of single-shot fast spin-echo sequence and T2-weighted fast spin-echo sequence in MR imaging of the brain

    International Nuclear Information System (INIS)

    Cha, Sung Ho; Seo, Jeong Jin; Jeong, Gwang Woo; Kim, Jae Kyu; Kim, Yun Hyeon; Jeong, Yong Yeon; Kang, Heoung Keun; Oh, Hee Yeon; Yoon, Jong Hoon

    1998-01-01

    The purpose of this study was to evaluate the usefulness of the single-shot fast spinecho (SS-FSE) sequence in comparison with the T2-weighted fast spin-echo (T2-FSE) sequence in brain MR imaging. In 41 patients aged 15-75 years with intracranial lesion, both SS-FSE and T2-FES images were obtained using a 1.5-T MR system. Lesions included cerebral ischemia or infarcts (n=3D23), tumors (n=3D10), hemorrhages (n=3D3), inflammatory diseases (n=3D2), arachnoid cysts(n=3D2), and vascular disease (n=3D1), and the MR images were retrospectively evaluated. To calculate contrast-to-noise ratio (CNR), percentage contrast, and signal-to-noise ratio (SNR)-and thus make a quantitative comparison-the mean signal intensities of lesions, normal brain tissue, and noise out-side the patient were measured. For qualitative comparison, the visibility, margin, and extent of the lesions were rated using a five-grade system, and the degree of MR artifacts was also evaluated. Wilcoxon's signed ranks test was used for statistical analysis. The mean CNR of lesions was significantly higher on SS-FSE (31.3) than on T2-FSE images (27.5) (p=3D0.0131). Mean percentage contrast was also higher on SS-FSE (159.0) than on T2-FSE images (108.5) (p=3D0.0222), but mean SNR was higher on T2-FSE (80.3) than on SS-FSE images (53.5) (p=3D0.0000). No significant differences in lesion visibility were observed between the two imaging sequences, though margin and extent of the lesion were worse on SS-FSE images. For MR artifacts, no significant differences were demonstrated. For the evaluation of most intracranial lesions, MR imaging using the SS-FSE sequence appears to be slightly inferior to the T2-FSE sequence, but may be useful where patients are ill or uncooperative, or where children require sedation.=20

  2. Fast and flexible selection with a single switch.

    Directory of Open Access Journals (Sweden)

    Tamara Broderick

    Full Text Available Selection methods that require only a single-switch input, such as a button click or blink, are potentially useful for individuals with motor impairments, mobile technology users, and individuals wishing to transmit information securely. We present a single-switch selection method, "Nomon," that is general and efficient. Existing single-switch selection methods require selectable options to be arranged in ways that limit potential applications. By contrast, traditional operating systems, web browsers, and free-form applications (such as drawing place options at arbitrary points on the screen. Nomon, however, has the flexibility to select any point on a screen. Nomon adapts automatically to an individual's clicking ability; it allows a person who clicks precisely to make a selection quickly and allows a person who clicks imprecisely more time to make a selection without error. Nomon reaps gains in information rate by allowing the specification of beliefs (priors about option selection probabilities and by avoiding tree-based selection schemes in favor of direct (posterior inference. We have developed both a Nomon-based writing application and a drawing application. To evaluate Nomon's performance, we compared the writing application with a popular existing method for single-switch writing (row-column scanning. Novice users wrote 35% faster with the Nomon interface than with the scanning interface. An experienced user (author TB, with 10 hours practice wrote at speeds of 9.3 words per minute with Nomon, using 1.2 clicks per character and making no errors in the final text.

  3. A modified fast-track program for pancreatic surgery: a prospective single-center experience.

    Science.gov (United States)

    di Sebastiano, Pierluigi; Festa, Leonardina; De Bonis, Antonio; Ciuffreda, Andrea; Valvano, Maria Rosa; Andriulli, Angelo; di Mola, F Francesco

    2011-03-01

    The objective of this study is to evaluate the impact of a fast-track protocol in a high-volume center for patients with pancreatic disorders. The concept of fast-track surgery allowing accelerated postoperative recovery is accepted in colorectal surgery, but efficacy data are only preliminary for patients undergoing major pancreatic surgery. We aimed to evaluate the impact of a modified fast-track protocol in a high-volume center for patients with pancreatic disorders. Between February 2005 and January 2010, 145 subjects had resective pancreatic surgery and were enrolled in the program. Essential features of the program were no preanaesthetic medication, upper and lower air-warming device, avoidance of excessive i.v. fluids perioperatively, effective control of pain, early reinstitution of oral feeding, and immediate mobilization and restoration of bowel function following surgery. Outcome measures were postoperative complications such as pancreatic fistula, delayed gastric emptying, biliary leak, intra-abdominal abscess, post-pancreatectomy hemorrhage, acute pancreatitis, wound infection, 30-day mortality, postoperative hospital stay, and readmission rates. On average, patients were discharged on postoperative day 10 (range 6-69), with a 30-day readmission rate of 6.2%. Percentage of patients with at least one complication was 38.6%. Pancreatic anastomotic leakage occurred in seven of 101 pancreatico-jejunostomies, and biliary leak in three of 109 biliary jejunostomies. Postoperative hemorrhage occurred in ten (6.9%) patients and wound infection in nine (6.2%) cases. In-hospital mortality was 2.7%. Fast-track parameters, such as normal food and first stool, correlated significantly with early discharge (jaundice, and resumption of normal diet by the 5th postoperative day were independent factors of early discharge. Fast-track programs are feasible, easy, and also applicable for patients undergoing a major surgery such as pancreatic resection.

  4. Effects of fasting and feeding on the fast-start swimming performance of southern catfish Silurus meridionalis.

    Science.gov (United States)

    Yan, G J; He, X K; Cao, Z D; Fu, S J

    2015-01-21

    This study investigated the effects of fasting and feeding on the fast-start escape swimming performance of juvenile southern catfish Silurus meridionalis, a sit-and-wait forager that encounters extreme fasting and famine frequently during its lifespan. Ten to 30 days of fasting resulted in no significant change in most of the variables measured in the fast-start response except a 20-30% decrease in the escape distance during the first 120 ms (D 120ms ) relative to the control group (48 h after feeding). The ratio of the single-bend (SB) response (lower energetic expenditure) to the double-bend (DB) response increased significantly from 0% in the control group to 75 and 82·5% in the 20 and 30 day fasting groups, respectively. Satiated feeding (25% of body mass) resulted in a significantly lower (36·6%) maximum linear velocity (V max ) and a significantly lower (43·3%) D 120ms than in non-fed fish (control group, 48 h after feeding). Half-satiated feeding (12·5% of body mass), however, showed no significant effects on any of the measured variables of the fast-start response relative to control fish. It is suggested that the increase in the ratio of SB:DB responses with fasting in S. meridionalis may reflect a trade-off between energy conservation and maintaining high V max , while variables of fast-start performance were more sensitive to feeding than fasting might be an adaptive strategy to their foraging mode and food availability in their habitat. © 2015 The Fisheries Society of the British Isles.

  5. Fast temporal fluctuations in single-molecule junctions.

    Science.gov (United States)

    Ochs, Roif; Secker, Daniel; Elbing, Mark; Mayor, Marcel; Weber, Heiko B

    2006-01-01

    The noise within the electrical current through single-molecule junctions is studied cryogenic temperature. The organic sample molecules were contacted with the mechanically controlled break-junction technique. The noise spectra refer to a where only few Lorentzian fluctuators occur in the conductance. The frequency dependence shows qualitative variations from sample to sample.

  6. Single-photon sources based on single molecules in solids

    International Nuclear Information System (INIS)

    Moerner, W E

    2004-01-01

    Single molecules in suitable host crystals have been demonstrated to be useful single-photon emitters both at liquid-helium temperatures and at room temperature. The low-temperature source achieved controllable emission of single photons from a single terrylene molecule in p-terphenyl by an adiabatic rapid passage technique. In contrast with almost all other single-molecule systems, terrylene single molecules show extremely high photostability under continuous, high-intensity irradiation. A room-temperature source utilizing this material has been demonstrated, in which fast pumping into vibrational sidebands of the electronically excited state achieved efficient inversion of the emissive level. This source yielded a single-photon emission probability p(1) of 0.86 at a detected count rate near 300 000 photons s -1 , with very small probability of emission of more than one photon. Thus, single molecules in solids can be considered as contenders for applications of single-photon sources such as quantum key distribution

  7. Fast time-resolved aerosol collector: proof of concept

    Science.gov (United States)

    Yu, X.-Y.; Cowin, J. P.; Iedema, M. J.; Ali, H.

    2010-10-01

    Atmospheric particles can be collected in the field on substrates for subsequent laboratory analysis via chemically sensitive single particle methods such as scanning electron microscopy with energy dispersive x-ray analysis. With moving substrates time resolution of seconds to minutes can be achieved. In this paper, we demonstrate how to increase the time resolution when collecting particles on a substrate to a few milliseconds to provide real-time information. Our fast time-resolved aerosol collector ("Fast-TRAC") microscopically observes the particle collection on a substrate and records an on-line video. Particle arrivals are resolved to within a single frame (4-17 ms in this setup), and the spatial locations are matched to the subsequent single particle analysis. This approach also provides in-situ information on particle size and number concentration. Applications are expected in airborne studies of cloud microstructure, pollution plumes, and surface long-term monitoring.

  8. 60 MHz fast wave current drive experiment for DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Mayberry, M.J.; Chiu, S.C.; Porkolab, M.; Chan, V.; Freeman, R.; Harvey, R.; Pinsker, R. (General Atomics, San Diego, CA (USA))

    1989-07-01

    The DIII-D facility provides an opportunity to test fast wave current drive appoach. Efficient FWCD is achieved by direct electron absorption due to Landa damping and transit time magnetic pumping. To avoid competing damping mechamisms we seek to maximize the single-pass asorption of the fast waves by electrons. (AIP)

  9. Fast Fourier transform telescope

    International Nuclear Information System (INIS)

    Tegmark, Max; Zaldarriaga, Matias

    2009-01-01

    We propose an all-digital telescope for 21 cm tomography, which combines key advantages of both single dishes and interferometers. The electric field is digitized by antennas on a rectangular grid, after which a series of fast Fourier transforms recovers simultaneous multifrequency images of up to half the sky. Thanks to Moore's law, the bandwidth up to which this is feasible has now reached about 1 GHz, and will likely continue doubling every couple of years. The main advantages over a single dish telescope are cost and orders of magnitude larger field-of-view, translating into dramatically better sensitivity for large-area surveys. The key advantages over traditional interferometers are cost (the correlator computational cost for an N-element array scales as Nlog 2 N rather than N 2 ) and a compact synthesized beam. We argue that 21 cm tomography could be an ideal first application of a very large fast Fourier transform telescope, which would provide both massive sensitivity improvements per dollar and mitigate the off-beam point source foreground problem with its clean beam. Another potentially interesting application is cosmic microwave background polarization.

  10. The integral fast reactor

    International Nuclear Information System (INIS)

    Till, C.E.

    1987-01-01

    On April 3rd, 1986, two demonstrations of the inherent capability of sodium-cooled fast reactors to survive unprotected loss of cooling accidents were carried out on the experimental sodium-cooled power reactor, EBR-II, on the Idaho site of Argonne National Laboratory. Transients potentially of the most serious kind, one an unprotected loss of flow, the other an unprotected loss of heat sink, both initiated from full power. In both cases the reactor quietly shut itself down, without damage of any kind. These tests were a part of the on-going development program at Argonne to develop an advanced reactor with significant new inherent safety characteristics. Called the integral fast reactor, or IFR, the basic thrust is to develop everything that is needed for a complete nuclear power system - reactor, closed fuel cycle, and waste processing - as a single optimized entity, and, for simplicity in concept, as an integral part of a single plant. The particular selection of reactor materials emphasizes inherent safety characteristics also makes possible a simplified close fuel cycle and waste process improvements. The paper describes the IFR concept, the inherent safety, tests, and status of IFR development today

  11. Reliability of Serum Metabolites over a Two-Year Period: A Targeted Metabolomic Approach in Fasting and Non-Fasting Samples from EPIC

    Science.gov (United States)

    Achaintre, David; Sacerdote, Carlotta; Vineis, Paolo; Key, Timothy J.; Onland Moret, N. Charlotte; Scalbert, Augustin; Rinaldi, Sabina; Ferrari, Pietro

    2015-01-01

    Objective Although metabolic profiles have been associated with chronic disease risk, lack of temporal stability of metabolite levels could limit their use in epidemiological investigations. The present study aims to evaluate the reliability over a two-year period of 158 metabolites and compare reliability over time in fasting and non-fasting serum samples. Methods Metabolites were measured with the AbsolueIDQp180 kit (Biocrates, Innsbruck, Austria) by mass spectrometry and included acylcarnitines, amino acids, biogenic amines, hexoses, phosphatidylcholines and sphingomyelins. Measurements were performed on repeat serum samples collected two years apart in 27 fasting men from Turin, Italy, and 39 non-fasting women from Utrecht, The Netherlands, all participating in the European Prospective Investigation into Cancer and Nutrition (EPIC) study. Reproducibility was assessed by estimating intraclass correlation coefficients (ICCs) in multivariable mixed models. Results In fasting samples, a median ICC of 0.70 was observed. ICC values were fasting samples, the median ICC was 0.54. ICC values were fasting as compared to fasting samples, with a statistically significant difference for 19–36% of acylcarnitines, phosphatidylcholines and sphingomyelins. Conclusion A single measurement per individual may be sufficient for the study of 73% and 52% of the metabolites showing ICCs >0.50 in fasting and non-fasting samples, respectively. ICCs were higher in fasting samples that are preferable to non-fasting. PMID:26274920

  12. EVALUATION OF A FAST-RESPONSE URBAN WIND MODEL - COMPARISON TO SINGLE-BUILDING WIND TUNNEL DATA

    International Nuclear Information System (INIS)

    E.R. PARDYJAK; M.J. BROWN

    2001-01-01

    Prediction of the 3-dimensional flow field around buildings and other obstacles is important for a number of applications, including urban air quality studies, the tracking of plumes from accidental releases of toxic air contaminants, indoor/outdoor air pollution problems, and thermal comfort assessments. Various types of computational fluid dynamics (CFD) models have been used for determining the flow fields around buildings (e.g., Reisner et al., 1998; Eichhorn et al., 1988). Comparisons to measurements show that these models work reasonably well for the most part (e.g., Ehrhard et al., 2 ; Johnson and Hunter, 1998; Murakami, 1997). However, CFD models are computationally intensive and for some applications turn-around time is of the essence. For example, planning and assessment studies in which hundreds of cases must be analyzed or emergency response scenarios in which plume transport must be computed quickly. Several fast-response dispersion models of varying levels of fidelity have been developed to explicitly account for the effects of a single building or groups of buildings (e.g., UDM - Hall et al. (2000), NRC-Ramsdell and Fosmire (1995), CBP-3 - Yamartino and Wiegand (1986), APRAC - Daerdt et al. (1973)). Although a few of these models include the Hotchkiss and Harlow (1973) analytical solution for potential flow in a notch to describe the velocity field within an urban canyon, in general, these models do not explicitly compute the velocity field around groups of buildings. The EPA PRIME model (Schulman et al., 2000) has been empirically derived to provide streamlines around a single isolated building

  13. SU-E-T-79: Comparison of Doses Received by the Hippocampus in Patients Treated with Single Vs Multiple Isocenter Based Stereotactic Radiation Therapy to the Brain for Multiple Brain Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Algan, O; Giem, J; Young, J; Ali, I; Ahmad, S; Hossain, S [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2014-06-01

    Purpose: To investigate the doses received by the hippocampus and normal brain tissue during a course of stereotactic radiotherapy utilizing a single isocenter (SI) versus multiple isocenter (MI) in patients with multiple intracranial metastases. Methods: Seven patients imaged with MRI including SPGR sequence and diagnosed with 2–3 brain metastases were included in this retrospective study. Two sets of stereotactic IMRT treatment plans, (MI vs SI), were generated. The hippocampus was contoured on SPGR sequences and doses received by the hippocampus and whole brain were calculated. The prescribed dose was 25Gy in 5 fractions. The two groups were compared using t-test analysis. Results: There were 17 lesions in 7 patients. The median tumor, right hippocampus, left hippocampus and brain volumes were: 3.37cc, 2.56cc, 3.28cc, and 1417cc respectively. In comparing the two treatment plans, there was no difference in the PTV coverage except in the tail of the DVH curve. All tumors had V95 > 99.5%. The only statistically significant parameter was the V100 (72% vs 45%, p=0.002, favoring MI). All other evaluated parameters including the V95 and V98 did not reveal any statistically significant differences. None of the evaluated dosimetric parameters for the hippocampus (V100, V80, V60, V40, V20, V10, D100, D90, D70, D50, D30, D10) revealed any statistically significant differences (all p-values > 0.31) between MI and SI plans. The total brain dose was slightly higher in the SI plans, especially in the lower dose regions, although this difference was not statistically significant. Utilizing brain-sub-PTV volumes did not change these results. Conclusion: The use of SI treatment planning for patients with up to 3 brain metastases produces similar PTV coverage and similar normal tissue doses to the hippocampus and the brain compared to MI plans. SI treatment planning should be considered in patients with multiple brain metastases undergoing stereotactic treatment.

  14. SU-E-T-79: Comparison of Doses Received by the Hippocampus in Patients Treated with Single Vs Multiple Isocenter Based Stereotactic Radiation Therapy to the Brain for Multiple Brain Metastases

    International Nuclear Information System (INIS)

    Algan, O; Giem, J; Young, J; Ali, I; Ahmad, S; Hossain, S

    2014-01-01

    Purpose: To investigate the doses received by the hippocampus and normal brain tissue during a course of stereotactic radiotherapy utilizing a single isocenter (SI) versus multiple isocenter (MI) in patients with multiple intracranial metastases. Methods: Seven patients imaged with MRI including SPGR sequence and diagnosed with 2–3 brain metastases were included in this retrospective study. Two sets of stereotactic IMRT treatment plans, (MI vs SI), were generated. The hippocampus was contoured on SPGR sequences and doses received by the hippocampus and whole brain were calculated. The prescribed dose was 25Gy in 5 fractions. The two groups were compared using t-test analysis. Results: There were 17 lesions in 7 patients. The median tumor, right hippocampus, left hippocampus and brain volumes were: 3.37cc, 2.56cc, 3.28cc, and 1417cc respectively. In comparing the two treatment plans, there was no difference in the PTV coverage except in the tail of the DVH curve. All tumors had V95 > 99.5%. The only statistically significant parameter was the V100 (72% vs 45%, p=0.002, favoring MI). All other evaluated parameters including the V95 and V98 did not reveal any statistically significant differences. None of the evaluated dosimetric parameters for the hippocampus (V100, V80, V60, V40, V20, V10, D100, D90, D70, D50, D30, D10) revealed any statistically significant differences (all p-values > 0.31) between MI and SI plans. The total brain dose was slightly higher in the SI plans, especially in the lower dose regions, although this difference was not statistically significant. Utilizing brain-sub-PTV volumes did not change these results. Conclusion: The use of SI treatment planning for patients with up to 3 brain metastases produces similar PTV coverage and similar normal tissue doses to the hippocampus and the brain compared to MI plans. SI treatment planning should be considered in patients with multiple brain metastases undergoing stereotactic treatment

  15. Effectiveness of dynamic MRI for diagnosing pericicatricial minimal residual breast cancer following excisional biopsy

    International Nuclear Information System (INIS)

    Kawashima, Hiroko; Tawara, Mari; Suzuki, Masayuki; Matsui, Osamu; Kadoya, Masumi

    2001-01-01

    The purpose of this study was to investigate the effectiveness of dynamic MRI for diagnosing pericicatricial minimal residual breast cancer following excisional biopsy. Twenty-six patients who underwent excisional biopsy of a tumor or calcified lesion of the breast underwent gadolinium-enhanced dynamic MRI by the fat-saturated 2D fast spoiled gradient echo (SPGR) sequence (group 1), 24 patients by the spectral IR enhanced 3D fast gradient echo (Efgre3d) sequence (group 2). Pericicatricial residual cancer was confirmed histologically in 29 of the 50 patients. The overall sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of MRI for residual cancer diagnosis was 66, 81, 72, 83 and 63%. A nodular, thick and discontinuous enhanced rim around the scar is indicative of a residual tumor. However, false-positive findings due to granulation or proliferative fibrocystic change remain limitations

  16. Effectiveness of dynamic MRI for diagnosing pericicatricial minimal residual breast cancer following excisional biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kawashima, Hiroko E-mail: hirokok@med.kanazawa-u.ac.jp; Tawara, Mari; Suzuki, Masayuki; Matsui, Osamu; Kadoya, Masumi

    2001-10-01

    The purpose of this study was to investigate the effectiveness of dynamic MRI for diagnosing pericicatricial minimal residual breast cancer following excisional biopsy. Twenty-six patients who underwent excisional biopsy of a tumor or calcified lesion of the breast underwent gadolinium-enhanced dynamic MRI by the fat-saturated 2D fast spoiled gradient echo (SPGR) sequence (group 1), 24 patients by the spectral IR enhanced 3D fast gradient echo (Efgre3d) sequence (group 2). Pericicatricial residual cancer was confirmed histologically in 29 of the 50 patients. The overall sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of MRI for residual cancer diagnosis was 66, 81, 72, 83 and 63%. A nodular, thick and discontinuous enhanced rim around the scar is indicative of a residual tumor. However, false-positive findings due to granulation or proliferative fibrocystic change remain limitations.

  17. Fast tomosynthesis

    International Nuclear Information System (INIS)

    Klotz, E.; Linde, R.; Tiemens, U.; Weiss, H.

    1978-01-01

    A system has been constructed for fast tomosynthesis, whereby X-ray photographs are made of a single layer of an object. Twenty five X-ray tubes illuminate the object simultaneously at different angles. The resulting coded image is decoded by projecting it with a pattern of lenses that have the same form as the pattern of X-ray tubes. The coded image is optically correlated with the pattern of the sources. The scale of this can be adjusted so that the desired layer of the object is portrayed. Experimental results of its use in a hospital are presented. (C.F.)

  18. FAST: FAST Analysis of Sequences Toolbox

    Directory of Open Access Journals (Sweden)

    Travis J. Lawrence

    2015-05-01

    Full Text Available FAST (FAST Analysis of Sequences Toolbox provides simple, powerful open source command-line tools to filter, transform, annotate and analyze biological sequence data. Modeled after the GNU (GNU’s Not Unix Textutils such as grep, cut, and tr, FAST tools such as fasgrep, fascut, and fastr make it easy to rapidly prototype expressive bioinformatic workflows in a compact and generic command vocabulary. Compact combinatorial encoding of data workflows with FAST commands can simplify the documentation and reproducibility of bioinformatic protocols, supporting better transparency in biological data science. Interface self-consistency and conformity with conventions of GNU, Matlab, Perl, BioPerl, R and GenBank help make FAST easy and rewarding to learn. FAST automates numerical, taxonomic, and text-based sorting, selection and transformation of sequence records and alignment sites based on content, index ranges, descriptive tags, annotated features, and in-line calculated analytics, including composition and codon usage. Automated content- and feature-based extraction of sites and support for molecular population genetic statistics makes FAST useful for molecular evolutionary analysis. FAST is portable, easy to install and secure thanks to the relative maturity of its Perl and BioPerl foundations, with stable releases posted to CPAN. Development as well as a publicly accessible Cookbook and Wiki are available on the FAST GitHub repository at https://github.com/tlawrence3/FAST. The default data exchange format in FAST is Multi-FastA (specifically, a restriction of BioPerl FastA format. Sanger and Illumina 1.8+ FastQ formatted files are also supported. FAST makes it easier for non-programmer biologists to interactively investigate and control biological data at the speed of thought.

  19. Very Fast Estimation of Epicentral Distance and Magnitude from a Single Three Component Seismic Station Using Machine Learning Techniques

    Science.gov (United States)

    Ochoa Gutierrez, L. H.; Niño Vasquez, L. F.; Vargas-Jimenez, C. A.

    2012-12-01

    To minimize adverse effects originated by high magnitude earthquakes, early warning has become a powerful tool to anticipate a seismic wave arrival to an specific location and lets to bring people and government agencies opportune information to initiate a fast response. To do this, a very fast and accurate characterization of the event must be done but this process is often made using seismograms recorded in at least 4 stations where processing time is usually greater than the wave travel time to the interest area, mainly in coarse networks. A faster process can be done if only one three component seismic station is used that is the closest unsaturated station respect to the epicenter. Here we present a Support Vector Regression algorithm which calculates Magnitude and Epicentral Distance using only 5 seconds of signal since P wave onset. This algorithm was trained with 36 records of historical earthquakes where the input were regression parameters of an exponential function estimated by least squares, corresponding to the waveform envelope and the maximum value of the observed waveform for each component in one single station. A 10 fold Cross Validation was applied for a Normalized Polynomial Kernel obtaining the mean absolute error for different exponents and complexity parameters. Magnitude could be estimated with 0.16 of mean absolute error and the distance with an error of 7.5 km for distances within 60 to 120 km. This kind of algorithm is easy to implement in hardware and can be used directly in the field station to make possible the broadcast of estimations of this values to generate fast decisions at seismological control centers, increasing the possibility to have an effective reactiontribute and Descriptors calculator for SVR model training and test

  20. FAST - A multiprocessed environment for visualization of computational fluid dynamics

    International Nuclear Information System (INIS)

    Bancroft, G.V.; Merritt, F.J.; Plessel, T.C.; Kelaita, P.G.; Mccabe, R.K.

    1991-01-01

    The paper presents the Flow Analysis Software Toolset (FAST) to be used for fluid-mechanics analysis. The design criteria for FAST including the minimization of the data path in the computational fluid-dynamics (CFD) process, consistent user interface, extensible software architecture, modularization, and the isolation of three-dimensional tasks from the application programmer are outlined. Each separate process communicates through the FAST Hub, while other modules such as FAST Central, NAS file input, CFD calculator, surface extractor and renderer, titler, tracer, and isolev might work together to generate the scene. An interprocess communication package making it possible for FAST to operate as a modular environment where resources could be shared among different machines as well as a single host is discussed. 20 refs

  1. Velocity-space tomography of the fast-ion distribution function

    DEFF Research Database (Denmark)

    Jacobsen, Asger Schou; Salewski, Mirko; Geiger, Benedikt

    2013-01-01

    probes certain regions in velocity-space, determined by the geometry of the set-up. Exploiting this, the fast-ion distribution function can be inferred using a velocity-space tomography method. This poster contains a tomography calculated from measured spectra from three different FIDA views at ASDEX......Fast ions play an important role in heating the plasma in a magnetic confinement fusion device. Fast-ion Dα(FIDA) spectroscopy diagnoses fast ions in small measurement volumes. Spectra measured by a FIDA diagnostic can be related to the 2D fast-ion velocity distribution function. A single FIDA view...... Upgrade. The quality of the tomography improves with the number of FIDA views simultaneously measuring the same volume. To investigate the potential benefits of including additional views (up to 18), tomographies are inferred from synthetic spectra calculated from a simulated distribution function...

  2. Fast data processing with Spark

    CERN Document Server

    Sankar, Krishna

    2015-01-01

    Fast Data Processing with Spark - Second Edition is for software developers who want to learn how to write distributed programs with Spark. It will help developers who have had problems that were too big to be dealt with on a single computer. No previous experience with distributed programming is necessary. This book assumes knowledge of either Java, Scala, or Python.

  3. Application of reflective memory network in Tokamak fast controller

    International Nuclear Information System (INIS)

    Weng Chuqiao; Zhang Ming; Liu Rui; Zheng Wei; Zhuang Ge

    2014-01-01

    A specific application of reflective memory network in Tokamak fast controller was introduced in this paper. The PMC-5565 reflective memory card and ACC-5565 network hub were used to build a reflective memory real-time network to test its real- time function. The real-time, rapidity and determinacy of the time delay for fast controller controlling power device under the reflective memory network were tested in the LabVIEW RT real-time operation system. Depending on the reflective memory technology, the data in several fast controllers were synchronized, and multiple control tasks using a single control task were finished. The experiment results show that the reflective memory network can meet the real-time requirements for fast controller to perform the feedback control over devices. (authors)

  4. Detection of single quantum dots in model organisms with sheet illumination microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, Mike; Nozadze, Revaz; Gan, Qiang; Zelman-Femiak, Monika; Ermolayev, Vladimir [Molecular Microscopy Group, Rudolf Virchow Center, University of Wuerzburg, Versbacher Str. 9, D-97078 Wuerzburg (Germany); Wagner, Toni U. [Institute of Physiological Chemistry I, Biocenter, University of Wuerzburg, Am Hubland, D-97074 Wuerzburg (Germany); Harms, Gregory S., E-mail: gregory.harms@virchow.uni-wuerzburg.de [Molecular Microscopy Group, Rudolf Virchow Center, University of Wuerzburg, Versbacher Str. 9, D-97078 Wuerzburg (Germany)

    2009-12-18

    Single-molecule detection and tracking is important for observing biomolecule interactions in the microenvironment. Here we report selective plane illumination microscopy (SPIM) with single-molecule detection in living organisms, which enables fast imaging and single-molecule tracking and optical penetration beyond 300 {mu}m. We detected single nanocrystals in Drosophila larvae and zebrafish embryo. We also report our first tracking of single quantum dots during zebrafish development, which displays a transition from flow to confined motion prior to the blastula stage. The new SPIM setup represents a new technique, which enables fast single-molecule imaging and tracking in living systems.

  5. Detection of single quantum dots in model organisms with sheet illumination microscopy

    International Nuclear Information System (INIS)

    Friedrich, Mike; Nozadze, Revaz; Gan, Qiang; Zelman-Femiak, Monika; Ermolayev, Vladimir; Wagner, Toni U.; Harms, Gregory S.

    2009-01-01

    Single-molecule detection and tracking is important for observing biomolecule interactions in the microenvironment. Here we report selective plane illumination microscopy (SPIM) with single-molecule detection in living organisms, which enables fast imaging and single-molecule tracking and optical penetration beyond 300 μm. We detected single nanocrystals in Drosophila larvae and zebrafish embryo. We also report our first tracking of single quantum dots during zebrafish development, which displays a transition from flow to confined motion prior to the blastula stage. The new SPIM setup represents a new technique, which enables fast single-molecule imaging and tracking in living systems.

  6. Fast Physics Testbed for the FASTER Project

    Energy Technology Data Exchange (ETDEWEB)

    Lin, W.; Liu, Y.; Hogan, R.; Neggers, R.; Jensen, M.; Fridlind, A.; Lin, Y.; Wolf, A.

    2010-03-15

    This poster describes the Fast Physics Testbed for the new FAst-physics System Testbed and Research (FASTER) project. The overall objective is to provide a convenient and comprehensive platform for fast turn-around model evaluation against ARM observations and to facilitate development of parameterizations for cloud-related fast processes represented in global climate models. The testbed features three major components: a single column model (SCM) testbed, an NWP-Testbed, and high-resolution modeling (HRM). The web-based SCM-Testbed features multiple SCMs from major climate modeling centers and aims to maximize the potential of SCM approach to enhance and accelerate the evaluation and improvement of fast physics parameterizations through continuous evaluation of existing and evolving models against historical as well as new/improved ARM and other complementary measurements. The NWP-Testbed aims to capitalize on the large pool of operational numerical weather prediction products. Continuous evaluations of NWP forecasts against observations at ARM sites are carried out to systematically identify the biases and skills of physical parameterizations under all weather conditions. The highresolution modeling (HRM) activities aim to simulate the fast processes at high resolution to aid in the understanding of the fast processes and their parameterizations. A four-tier HRM framework is established to augment the SCM- and NWP-Testbeds towards eventual improvement of the parameterizations.

  7. Fast FIB-milled Electron-transparent Microchips for in situ TEM Investigations

    DEFF Research Database (Denmark)

    Lei, Anders; Petersen, Dirch Hjorth; Kallesøe, Christian

    In this work we present a fast approach to 50 nm resolution structures defined in a generic TEM-chip template in few minutes. While creating complex electrical and NEMS circuits for a specific insitu TEM experiment can be a cumbersome process, microchips with 100 nm thin flakes of single crystall......In this work we present a fast approach to 50 nm resolution structures defined in a generic TEM-chip template in few minutes. While creating complex electrical and NEMS circuits for a specific insitu TEM experiment can be a cumbersome process, microchips with 100 nm thin flakes of single...

  8. New Software for the Fast Estimation of Population Recombination Rates (FastEPRR in the Genomic Era

    Directory of Open Access Journals (Sweden)

    Feng Gao

    2016-06-01

    Full Text Available Genetic recombination is a very important evolutionary mechanism that mixes parental haplotypes and produces new raw material for organismal evolution. As a result, information on recombination rates is critical for biological research. In this paper, we introduce a new extremely fast open-source software package (FastEPRR that uses machine learning to estimate recombination rate ρ (=4Ner from intraspecific DNA polymorphism data. When ρ>10 and the number of sampled diploid individuals is large enough (≥50, the variance of ρFastEPRR remains slightly smaller than that of ρLDhat. The new estimate ρcomb (calculated by averaging ρFastEPRR and ρLDhat has the smallest variance of all cases. When estimating ρFastEPRR, the finite-site model was employed to analyze cases with a high rate of recurrent mutations, and an additional method is proposed to consider the effect of variable recombination rates within windows. Simulations encompassing a wide range of parameters demonstrate that different evolutionary factors, such as demography and selection, may not increase the false positive rate of recombination hotspots. Overall, accuracy of FastEPRR is similar to the well-known method, LDhat, but requires far less computation time. Genetic maps for each human population (YRI, CEU, and CHB extracted from the 1000 Genomes OMNI data set were obtained in less than 3 d using just a single CPU core. The Pearson Pairwise correlation coefficient between the ρFastEPRR and ρLDhat maps is very high, ranging between 0.929 and 0.987 at a 5-Mb scale. Considering that sample sizes for these kinds of data are increasing dramatically with advances in next-generation sequencing technologies, FastEPRR (freely available at http://www.picb.ac.cn/evolgen/ is expected to become a widely used tool for establishing genetic maps and studying recombination hotspots in the population genomic era.

  9. The electron-impact ionization of Ar and Kr revisited: A critical analysis of double-to-single ionization cross section ratio measurements using the fast-atom-beam technique

    International Nuclear Information System (INIS)

    Tarnovsky, V.; Becker, K.

    1992-01-01

    We report new measurements of the absolute electron-impact double ionization cross sections for Ar and Kr and of the ratios of double-to-single ionization for impact energies from threshold to 200 eV using the crossed electron-beam - fast-atom-beam technique. The work was motivated by the recently highlighted spread of about 30% in the Ar 2+ /Ar + ionization cross section ratios obtained by several groups using different experimental techniques. Such a spread is inconsistent with statistical uncertainties of typically 3% or less that were quoted for the various reported ratios. A similar situation exists for Kr where the spread among the recently published Kr 2+ /Kr + ionization cross section ratios is about 15%. We made an attempt to identify all potential systematic errors inherent to the fast-beam technique that could affect the measurement of cross section ratios with special emphasis on those systematic errors that could influence the detection of singly and doubly charged product ions differently. We found Ar 2+ /Ar + and Kr 2+ /Kr + cross section ratios of, respectively 0.066±0.007 and 0.087±0.008 at 100 eV which confirm earlier measurements using the same experimental technique. The error limits on cross sections ratios of multiple-to-single ionization for the same target atom and at least ±10% for ratios of single ionization cross sections for different target species. Our error limits are dominated by systematic uncertainties of the apparatus which do not cancel when cross section ratios are measured, since the ratios are obtained under similar, but not identical experimental conditions. (orig.)

  10. Breeding gains of sodium-cooled oxide-fueled fast reactors

    International Nuclear Information System (INIS)

    Mougniot, J.C.; Barre, J.Y.; Clauzon, P.; Ciacometti, C.; Neviere, G.; Ravier, J.; Sichard, B.

    Calculated values are presented for the breeding gains of French fast reactors, and the experimental uncertainties are discussed. The effect of various choices of planning on the breeding gains is next analyzed within the framework of classical concepts. In the final part, a new concept involving ''heterogeneous cores'' with a single enrichment zone is presented. This concept permits a significant improvement in the breeding gain and doubling time of fast reactors. (U.S.)

  11. Observing the Sun with the Atacama Large Millimeter/submillimeter Array (ALMA): Fast-Scan Single-Dish Mapping

    Science.gov (United States)

    White, S. M.; Iwai, K.; Phillips, N. M.; Hills, R. E.; Hirota, A.; Yagoubov, P.; Siringo, G.; Shimojo, M.; Bastian, T. S.; Hales, A. S.; Sawada, T.; Asayama, S.; Sugimoto, M.; Marson, R. G.; Kawasaki, W.; Muller, E.; Nakazato, T.; Sugimoto, K.; Brajša, R.; Skokić, I.; Bárta, M.; Kim, S.; Remijan, A. J.; de Gregorio, I.; Corder, S. A.; Hudson, H. S.; Loukitcheva, M.; Chen, B.; De Pontieu, B.; Fleishmann, G. D.; Gary, D. E.; Kobelski, A.; Wedemeyer, S.; Yan, Y.

    2017-07-01

    The Atacama Large Millimeter/submillimeter Array (ALMA) radio telescope has commenced science observations of the Sun starting in late 2016. Since the Sun is much larger than the field of view of individual ALMA dishes, the ALMA interferometer is unable to measure the background level of solar emission when observing the solar disk. The absolute temperature scale is a critical measurement for much of ALMA solar science, including the understanding of energy transfer through the solar atmosphere, the properties of prominences, and the study of shock heating in the chromosphere. In order to provide an absolute temperature scale, ALMA solar observing will take advantage of the remarkable fast-scanning capabilities of the ALMA 12 m dishes to make single-dish maps of the full Sun. This article reports on the results of an extensive commissioning effort to optimize the mapping procedure, and it describes the nature of the resulting data. Amplitude calibration is discussed in detail: a path that uses the two loads in the ALMA calibration system as well as sky measurements is described and applied to commissioning data. Inspection of a large number of single-dish datasets shows significant variation in the resulting temperatures, and based on the temperature distributions, we derive quiet-Sun values at disk center of 7300 K at λ = 3 mm and 5900 K at λ = 1.3 mm. These values have statistical uncertainties of about 100 K, but systematic uncertainties in the temperature scale that may be significantly larger. Example images are presented from two periods with very different levels of solar activity. At a resolution of about 25'', the 1.3 mm wavelength images show temperatures on the disk that vary over about a 2000 K range. Active regions and plages are among the hotter features, while a large sunspot umbra shows up as a depression, and filament channels are relatively cool. Prominences above the solar limb are a common feature of the single-dish images.

  12. In vivo tibiofemoral cartilage-to-cartilage contact area of females with medial osteoarthritis under acute loading using MRI.

    Science.gov (United States)

    Shin, Choongsoo S; Souza, Richard B; Kumar, Deepak; Link, Thomas M; Wyman, Bradley T; Majumdar, Sharmila

    2011-12-01

    To investigate the effect of acute loading on in vivo tibiofemoral contact area changes in both compartments, and to determine whether in vivo tibiofemoral contact area differs between subjects with medial knee osteoarthritis (OA) and healthy controls. Ten subjects with medial knee OA (KL3) and 11 control subjects (KL0) were tested. Coronal three-dimensional spoiled gradient-recalled (3D-SPGR) and T(2) -weighted fast spin-echo FSE magnetic resonance imaging (MRI) of the knee were acquired under both unloaded and loaded conditions. Tibiofemoral cartilage contact areas were measured using image-based 3D models. Tibiofemoral contact areas in both compartments significantly increased under loading (P contact area in the medial compartment was significantly larger than in the lateral compartment (P contact area was significantly larger in KL3 subjects than KL0 subjects, both at unloaded and loaded conditions (P Contact areas measured from 3D-SPGR and T(2) -weighted FSE images were strongly correlated (r = 0.904). Females with medial OA increased tibiofemoral contact area in the medial compartment compared to healthy subjects under both unloaded and loaded conditions. The contact area data presented in this study may provide a quantitative reference for further cartilage contact biomechanics such as contact stress analysis and cartilage biomechanical function difference between osteoarthritic and healthy knees. Copyright © 2011 Wiley Periodicals, Inc.

  13. Fast Dump of the ATLAS Toroids

    CERN Document Server

    Dudarev, A; Volpini, Giovanni; Dudarev, Alexey; Kate, Herman Ten

    2010-01-01

    The toroidal magnet system of the ATLAS Detector at CERN consists of a Barrel Toroid (BT) and two End Cap Toroids (ECT-A and ECT-C). Each toroid is built up from eight racetrack coils wound with an aluminum stabilized NbTi conductor and indirectly cooled by forced flow liquid helium. The three toroids operate in series at 20.5 kA with a total stored energy of 1.5 GJ. In order to verify the reliability and effectiveness of the quench protection system, series of fast dump tests have been performed first of the single toroids and finally of the entire toroidal magnet system. In this paper a model to simulate the fast dump of the ATLAS toroids in single mode operation and in full system configuration is presented. The model is validated through comparison with measured data extracted from the ramp-and-quench runs. The calculated energy dissipation in the various coils is in very good agreement (within 1-2\\%) with the enthalpy changes estimated from the temperature measurements of the different parts of the cold ...

  14. One-trial overshadowing: Evidence for fast specific fear learning in humans.

    Science.gov (United States)

    Haesen, Kim; Beckers, Tom; Baeyens, Frank; Vervliet, Bram

    2017-03-01

    Adaptive defensive actions necessitate a fear learning system that is both fast and specific. Fast learning serves to minimize the number of threat confrontations, while specific learning ensures that the acquired fears are tied to threat-relevant cues only. In Pavlovian fear conditioning, fear acquisition is typically studied via repetitive pairings of a single cue with an aversive experience, which is not optimal for the examination of fast specific fear learning. In this study, we adopted the one-trial overshadowing procedure from basic learning research, in which a combination of two visual cues is presented once and paired with an aversive electrical stimulation. Using on-line shock expectancy ratings, skin conductance reactivity and startle reflex modulation as indices of fear learning, we found evidence of strong fear after a single conditioning trial (fast learning) as well as attenuated fear responding when only half of the trained stimulus combination was presented (specific learning). Moreover, specificity of fear responding tended to correlate with levels of state and trait anxiety. These results suggest that one-trial overshadowing can be used as a model to study fast specific fear learning in humans and individual differences therein. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Prospective Player-Reported Injuries in Female Youth Fast-Pitch Softball Players.

    Science.gov (United States)

    Smith, Matthew V; Davis, Randi; Brophy, Robert H; Prather, Heidi; Garbutt, Jane; Wright, Rick W

    2015-01-01

    There is a scarcity of literature evaluating injuries in youth fast-pitch softball players. To perform a descriptive analysis of player-reported injuries in youth fast-pitch softball position players and pitchers during a single select-level season. Prospective observation cohort study. Level 3. Ninety-eight athletes (48 pitchers, 50 position players) were followed for a single select fast-pitch softball season. Study participants completed web-based surveys every 3 weeks reporting injuries related to participation in fast-pitch softball. Injury was defined as pain causing cessation of participation in the current game or practice that prevents the player's return to that session or any pain that causes cessation of a player's customary participation on the day after the day of onset. The median age of the study participants was 14 years (range, 9-18 years). There were 49 reported injuries in 98 athletes. The average age was 13 years for those not injured and 14 years for those who were injured (P softball players. Better off-season and preseason conditioning may be a key factor for reducing pitching injuries. Recognition of injury patterns in fast-pitch softball players is critical to developing strategies to keep these athletes competing safely. © 2015 The Author(s).

  16. Prospective Player-Reported Injuries in Female Youth Fast-Pitch Softball Players

    Science.gov (United States)

    Smith, Matthew V.; Davis, Randi; Brophy, Robert H.; Prather, Heidi; Garbutt, Jane; Wright, Rick W.

    2015-01-01

    Background: There is a scarcity of literature evaluating injuries in youth fast-pitch softball players. Purpose: To perform a descriptive analysis of player-reported injuries in youth fast-pitch softball position players and pitchers during a single select-level season. Study Design: Prospective observation cohort study. Level of Evidence: Level 3. Methods: Ninety-eight athletes (48 pitchers, 50 position players) were followed for a single select fast-pitch softball season. Study participants completed web-based surveys every 3 weeks reporting injuries related to participation in fast-pitch softball. Injury was defined as pain causing cessation of participation in the current game or practice that prevents the player’s return to that session or any pain that causes cessation of a player’s customary participation on the day after the day of onset. Results: The median age of the study participants was 14 years (range, 9-18 years). There were 49 reported injuries in 98 athletes. The average age was 13 years for those not injured and 14 years for those who were injured (P softball players. Better off-season and preseason conditioning may be a key factor for reducing pitching injuries. Clinical Relevance: Recognition of injury patterns in fast-pitch softball players is critical to developing strategies to keep these athletes competing safely. PMID:26502442

  17. Single-Photon Technologies Based on Quantum-Dots in Photonic Crystals

    DEFF Research Database (Denmark)

    Lehmann, Tau Bernstorff

    -photon purity under quasi-resonantexcitation. Furthermore the waveguide based platform demonstrates indistinguishable single-photonsat timescales up to 13 ns.A setup for active demultiplexing of single-photons to a three-fold single-photon state is proposed.Using a fast electro-optical modulator, single...

  18. 85,000-GPM, single-stage, single-suction LMFBR intermediate centrifugal pump

    International Nuclear Information System (INIS)

    Fair, C.E.; Cook, M.E.; Huber, K.A.; Rohde, R.

    1983-01-01

    The mechanical and hydraulic design features of the 85,000-gpm, single-stage, single-suction pump test article, which is designed to circulate liquid-sodium coolant in the intermediate heat-transport system of a Large-Scale Liquid Metal Fast Breeder Reactor (LS-LMFBR), are described. The design and analytical considerations used to satisfy the pump performance and operability requirements are presented. The validation of pump hydraulic performance using a hydraulic scale-model pump is discussed, as is the featute test for the mechanical-shaft seal system

  19. Fast calcium transients translate the distribution and conduction of neural activity in different regions of a single sensory neuron.

    Science.gov (United States)

    Purali, Nuhan

    2017-09-01

    In the present study, cytosolic calcium concentration changes were recorded in response to various forms of excitations, using the fluorescent calcium indicator dye OG-BAPTA1 together with the current or voltage clamp methods in stretch receptor neurons of crayfish. A single action potential evoked a rise in the resting calcium level in the axon and axonal hillock, whereas an impulse train or a large saturating current injection would be required to evoke an equivalent response in the dendrite region. Under voltage clamp conditions, amplitude differences between axon and dendrite responses vanished completely. The fast activation time and the modulation of the response by extracellular calcium concentration changes indicated that the evoked calcium transients might be mediated by calcium entry into the cytosol through a voltage-gated calcium channel. The decay of the responses was slow and sensitive to extracellular sodium and calcium concentrations as well as exposure to 1-10 mM NiCl 2 and 10-500 µM lanthanum. Thus, a sodium calcium exchanger and a calcium ATPase might be responsible for calcium extrusion from the cytosol. Present results indicate that the calcium indicator OG-BAPTA1 might be an efficient but indirect way of monitoring regional membrane potential differences in a single neuron.

  20. Fast, low noise transimpedance preamplifier

    International Nuclear Information System (INIS)

    Parlakyan, L.K.

    1995-01-01

    A single-channel transimpedance preamplifier for fast dielectric detectors is described. The main specifications of the preamplifier are: rise time is 1,5 ns; gain is 3,5 mV/μ A (with two section- 210 mV/μ A); r.m.s input noise is 30 n A; power consumption is 22 m W. Depending on supply voltage, the parameters may vary in a wide range. 5 refs

  1. MR imaging of the gastrointestinal tract with half-fourier single-shot fast spin echo (SSFSE)

    International Nuclear Information System (INIS)

    Boku, Houjun; Takehara, Yasuo; Isoda, Haruo; Isogai, Satoshi; Kaneko, Masao

    1999-01-01

    Our objective was to implement a non-invasive magnetic resonance imaging (MRI) technique combined with concentrated milk ingestion for depicting the gastrointestinal (GI) tract and detecting gastrointestinal motility and transit. The half-Fourier SSFSE (single-shot fast spin echo) sequence was optimized on the basis of a phantom study. In order to determine the feasibility of milk ingestion as a substitute for contrast medium, ten human volunteers were examined with SSFSE after two types of liquid ingestion (i.e., milk and water). The snapshot images provided subsecond data acquisition for each coronal plane, allowing visualization of peristalsis in the gastrointestinal tract in an almost real-time fashion, without motion-related image degradation, as would normally be seen using conventional MRI. There was no significant difference between concentrated milk and water in terms of depiction of the upper gastrointestinal tract; however, 10 min and 30 min after ingestion, concentrated milk showed better delineation of the intestine than that observed after water ingestion (p<0.01). MR gastrointestinal imaging is a non-invasive method that allows gastrointestinal depiction as well as analysis of motility and passage. Especially with concentrated milk ingestion, the distal intestines were well depicted with adequate contrast filling and distention. (author)

  2. Electrically pumped single-photon emission at room temperature from a single InGaN/GaN quantum dot

    Energy Technology Data Exchange (ETDEWEB)

    Deshpande, Saniya; Frost, Thomas; Hazari, Arnab; Bhattacharya, Pallab, E-mail: pkb@eecs.umich.edu [Center for Photonics and Multiscale Nanomaterials, Department of Electrical Engineering and Computer Science, University of Michigan, 1301 Beal Avenue, Ann Arbor, Michigan 48109 (United States)

    2014-10-06

    We demonstrate a semiconductor quantum dot based electrically pumped single-photon source operating at room temperature. Single photons emitted in the red spectral range from single In{sub 0.4}Ga{sub 0.6}N/GaN quantum dots exhibit a second-order correlation value g{sup (2)}(0) of 0.29, and fast recombination lifetime ∼1.3 ±0.3 ns at room temperature. The single-photon source can be driven at an excitation repetition rate of 200 MHz.

  3. Crystal structures of Er4Ni13C4 and UW4C4

    International Nuclear Information System (INIS)

    Khalili, M.M.; Bodak, O.I.; Marusin, E.P.; Pecharskaya, A.O.

    1990-01-01

    Crystal structures of Er 4 Ni 13 C 4 (1) (sp.gr. Cmmm, a=1.1975(4), b=1.1694(3), c=0.3856(1) nm, Z=2) and UW 4 C 4 (2) (sp.gr. P4/m, a=0.8328(8), c=0.31345(9) nm, Z=2), relating to new types are determined. Structural type (1) is a derivative of La 2 Ni 5 C 3 structure, structural type (2) is close to UCr 4 C 4 structure

  4. McBits: fast constant-time code-based cryptography

    NARCIS (Netherlands)

    Bernstein, D.J.; Chou, T.; Schwabe, P.

    2015-01-01

    This paper presents extremely fast algorithms for code-based public-key cryptography, including full protection against timing attacks. For example, at a 2^128 security level, this paper achieves a reciprocal decryption throughput of just 60493 cycles (plus cipher cost etc.) on a single Ivy Bridge

  5. Neighborhood fast food availability and fast food consumption.

    Science.gov (United States)

    Oexle, Nathalie; Barnes, Timothy L; Blake, Christine E; Bell, Bethany A; Liese, Angela D

    2015-09-01

    Recent nutritional and public health research has focused on how the availability of various types of food in a person's immediate area or neighborhood influences his or her food choices and eating habits. It has been theorized that people living in areas with a wealth of unhealthy fast-food options may show higher levels of fast-food consumption, a factor that often coincides with being overweight or obese. However, measuring food availability in a particular area is difficult to achieve consistently: there may be differences in the strict physical locations of food options as compared to how individuals perceive their personal food availability, and various studies may use either one or both of these measures. The aim of this study was to evaluate the association between weekly fast-food consumption and both a person's perceived availability of fast-food and an objective measure of fast-food presence - Geographic Information Systems (GIS) - within that person's neighborhood. A randomly selected population-based sample of eight counties in South Carolina was used to conduct a cross-sectional telephone survey assessing self-report fast-food consumption and perceived availability of fast food. GIS was used to determine the actual number of fast-food outlets within each participant's neighborhood. Using multinomial logistic regression analyses, we found that neither perceived availability nor GIS-based presence of fast-food was significantly associated with weekly fast-food consumption. Our findings indicate that availability might not be the dominant factor influencing fast-food consumption. We recommend using subjective availability measures and considering individual characteristics that could influence both perceived availability of fast food and its impact on fast-food consumption. If replicated, our findings suggest that interventions aimed at reducing fast-food consumption by limiting neighborhood fast-food availability might not be completely effective

  6. Serum Lipid Profile: Fasting or Non-fasting?

    OpenAIRE

    Nigam, P. K.

    2010-01-01

    Serum lipid profile has now become almost a routine test. It is usually done in fasting state due to certain limitations in non-fasting serum sample. In the recent past efforts have been made to simplify blood sampling by replacing fasting lipid profile with non-fasting lipid profile. However, fasting specimen is preferred if cardiovascular risk assessment is based on total cholesterol, LDL cholesterol or non-HDL cholesterol. A lot has yet to be done in this area. Till then we have to believe...

  7. Focusing light through dynamical samples using fast continuous wavefront optimization.

    Science.gov (United States)

    Blochet, B; Bourdieu, L; Gigan, S

    2017-12-01

    We describe a fast continuous optimization wavefront shaping system able to focus light through dynamic scattering media. A micro-electro-mechanical system-based spatial light modulator, a fast photodetector, and field programmable gate array electronics are combined to implement a continuous optimization of a wavefront with a single-mode optimization rate of 4.1 kHz. The system performances are demonstrated by focusing light through colloidal solutions of TiO 2 particles in glycerol with tunable temporal stability.

  8. FAST TCP over optical burst switched networks: Modeling and stability analysis

    KAUST Repository

    Shihada, Basem

    2013-04-01

    FAST TCP is important for promoting data-intensive applications since it can cleverly react to both packet loss and delay for detecting network congestion. This paper provides a continuous time model and extensive stability analysis of FAST TCP congestion-control mechanism in bufferless Optical Burst Switched Networks (OBS). The paper first shows that random burst contentions are essential to stabilize the network, but cause throughput degradation in FAST TCP flows when a burst with all the packets from a single round is dropped. Second, it shows that FAST TCP is vulnerable to burst delay and fails to detect network congestion due to the little variation of round-trip time, thus unstable. Finally it shows that introducing extra delays by implementing burst retransmission stabilizes FAST TCP over OBS. The paper proves that FAST TCP is not stable over barebone OBS. However, it is locally, exponentially, and asymptotically stable over OBS with burst retransmission.

  9. Fast-grown CdS quantum dots: Single-source precursor approach vs microwave route

    Energy Technology Data Exchange (ETDEWEB)

    Fregnaux, Mathieu [Laboratoire de Chimie et Physique: Approche Multi-échelles des Milieux Complexes, Institut Jean Barriol, Université de Lorraine, 1 Boulevard Arago, 57070 Metz (France); Dalmasso, Stéphane, E-mail: stephane.dalmasso@univ-lorraine.fr [Laboratoire de Chimie et Physique: Approche Multi-échelles des Milieux Complexes, Institut Jean Barriol, Université de Lorraine, 1 Boulevard Arago, 57070 Metz (France); Durand, Pierrick [Laboratoire de Cristallographie, Résonance Magnétique et Modélisations, Institut Jean Barriol, Université de Lorraine, UMR CNRS 7036, Faculté des Sciences, BP 70239, 54506 Vandoeuvre lès Nancy (France); Zhang, Yudong [Laboratoire d' Etude des Microstructures et de Mécanique des Matériaux, Université de Lorraine, UMR CNRS 7239, Ile du Saulcy, 57045 Metz cedex 01 (France); Gaumet, Jean-Jacques; Laurenti, Jean-Pierre [Laboratoire de Chimie et Physique: Approche Multi-échelles des Milieux Complexes, Institut Jean Barriol, Université de Lorraine, 1 Boulevard Arago, 57070 Metz (France)

    2013-10-01

    A cross-disciplinary protocol of characterization by joint techniques enables one to closely compare chemical and physical properties of CdS quantum dots (QDs) grown by single source precursor methodology (SSPM) or by microwave synthetic route (MWSR). The results are discussed in relation with the synthesis protocols. The QD average sizes, reproducible as a function of the temperatures involved in the growth processes, range complementarily in 2.8–4.5 nm and 4.5–5.2 nm for SSPM and MWSR, respectively. Hexagonal and cubic structures after X-ray diffraction on SSPM and MWSR grown CdS QDs, respectively, are tentatively correlated to a better crystalline quality of the latter with respect to the further ones, suggested by (i) a remarkable stability of the MWSR grown QDs after exposure to air during several days and (ii) no evidence of their fragmentation during mass spectrometry (MS) analyses, after a fair agreement between size dispersities obtained by transmission electron microscopy (TEM) and MS, in contrast with the discrepancy found for the SSPM grown QDs. Correlatively, a better optical quality is suggested for the MWSR grown QDs by the resolution of n > 1 excitonic transitions in their absorption spectra. The QD average sizes obtained by TEM and deduced from MS are in overall agreement. This agreement is improved for the MWSR grown QDs, taking into account a prolate shape of the QDs also observed in the TEM images. For both series of samples, the excitonic responses vs the average sizes are consistent with the commonly admitted empirical energy-size correspondence. A low energy PL band is observed in the case of the SSPM grown QDs. Its decrease in intensity with QD size increase suggests a surface origin tentatively attributed to S vacancies. In the case of the MWSR grown QDs, the absence of this PL is tentatively correlated to an absence of S vacancies and therefore to the stable behavior observed when the QDs are exposed to air. - Highlights: • Single

  10. Thermoelectric single-photon detector

    International Nuclear Information System (INIS)

    Kuzanyan, A A; Petrosyan, V A; Kuzanyan, A S

    2012-01-01

    The ability to detect a single photon is the ultimate level of sensitivity in the measurement of optical radiation. Sensors capable of detecting single photons and determining their energy have many scientific and technological applications. Kondo-enhanced Seebeck effect cryogenic detectors are based on thermoelectric heat-to-voltage conversion and voltage readout. We evaluate the prospects of CeB 6 and (La,Ce)B 6 hexaboride crystals for their application as a sensitive element in this type of detectors. We conclude that such detectors can register a single UV photon, have a fast count rate (up to 45 MHz) and a high spectral resolution of 0.1 eV. We calculate the electric potential generated along the thermoelectric sensor upon registering a UV single photon.

  11. Micro-analysis of plaque fluid from single-site fasted plaque

    International Nuclear Information System (INIS)

    Vogel, G.L.; Carey, C.M.; Chow, L.C.; Tatevossian, A.

    1990-01-01

    Despite the site-specific nature of caries, nearly all data on the concentration of ions relevant to the level of saturation of plaque fluid with respect to calcium phosphate minerals or enamel are from studies that used pooled samples. A procedure is described for the collection and analysis of inorganic ions relevant to these saturation levels in plaque fluid samples collected from a single surface on a single tooth. Various methods for examining data obtained by this procedure are described, and a mathematical procedure employing potential plots is recommended

  12. A fast ADC scanner for multiparameter nuclear physics experiments

    International Nuclear Information System (INIS)

    Midttun, G.; Ingebretsen, F.; Holt, K.; Skaali, B.

    1983-04-01

    A fast readout system for multiparameter experiments in nuclear physics is described. The central part of the CAMAC aquisition hardware is an ADC scanner module. The scanner incorporates a new arbitration logic and direct memory access for simultaneous transfer of singles and correlated data. Together with specially designed ADC interfaces the system can be set up for any configuration of singles and multiparameter events from 1 up to 15 ADC's in one crate

  13. A fast ADC scanner for multiparameter nuclear physics experiments

    International Nuclear Information System (INIS)

    Midttun, G.; Holt, K.; Ingebretsen, F.; Skaali, B.

    1983-01-01

    A fast readout system for multiparameter experiments in nuclear physics is described. The central part of the CAMAC aquisition hardware is an ADC scanner module. The scanner incorporates a new arbitration logic and direct memory access for simultaneous transfer of singles and correlated data. Together with specially designed ADC interfaces the system can be set up for any configurations of singles and multiparameter events from 1 up to 15 ADC's in one crate

  14. Performance Improvement for Two-Stage Single-Phase Grid-Connected Converters Using a Fast DC Bus Control Scheme and a Novel Synchronous Frame Current Controller

    Directory of Open Access Journals (Sweden)

    Bingzhang Li

    2017-03-01

    Full Text Available Two-stage single-phase grid-connected converters are widely used in renewable energy applications. Due to the presence of a second harmonic ripple across the DC bus voltage, it is very challenging to design the DC bus voltage control scheme in single-phase grid-connected inverters. The DC bus voltage controller must filter the ripple and balance a tradeoff between low harmonic distortion and high bandwidth. This paper presents a fast DC bus voltage controller, which uses a second order digital finite impulse response (FIR notch filter in conjunction with input power feedforward scheme to ensure the steady-state and dynamic performance. To gain the input power without extra hardware, a Kalman filter is incorporated to estimate the DC bus input current. At the same time, a modulation compensation strategy is implemented to eliminate the nonlinearity of the grid current control loop, which is caused by the DC bus voltage ripple. Moreover, a novel synchronous frame current controller for single-phase systems is also introduced, and its equivalent model in stationary frame has been derived. Simulation and experimental results are provided to verify the effective of the proposed control scheme.

  15. Sampling system for fast single pulses; Realisation d'un dispositif d'echantillonnage d'un signal bref unique

    Energy Technology Data Exchange (ETDEWEB)

    Zenatti, D. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    Development of a device for the enlargement of the domain of application of classical oscilloscopes to the observation of fast single pulses by application of the sampling principle. Its principal characteristics are: Bandwidth of 700 MHz; Maximum sensibility of 50 mV; Maximum amplitude of input signal of {+-} 1 V; Number of samples of 16; Samples separation of 0,2 ns. (author) [French] Realisation d'un dispositif permettant d'elargir le domaine d'utilisation des oscilloscopes classiques en appliquant le principe de l'echantillonnage a l'observation d'un signal bref unique. Les principales caracteristiques sont les suivantes: Bande passante de 700 MHz; Sensibilite maximale de 50 mV; Amplitude maximale du signal a echantillonner de {+-} 1 V; Nombre de points d'echantillonnage de 16; Pas d'echantillonnage de 0,2 ns. (auteur)

  16. The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements†

    Science.gov (United States)

    Pröfrock, Daniel; Irrgeher, Johanna; Prohaska, Thomas

    2016-01-01

    The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC, measurement repeatability, within-lab reproducibility and deviation from certified values as well as a study on instrumental isotopic fractionation (IIF) and the calculation of the combined standard measurement uncertainty. Different approaches of correction for IIF applying external intra-elemental IIF correction (aka standard-sample bracketing) using certified S reference materials and internal inter-elemental IIF (aka internal standardization) correction using Si isotope ratios in MC ICP-MS are explained and compared. The resulting combined standard uncertainties of examined ICP-QMS systems were not better than 0.3–0.5% (uc,rel), which is in general insufficient to differentiate natural S isotope variations. Although the performance of the single collector ICP-SFMS is better (single measurement uc,rel = 0.08%), the measurement reproducibility (>0.2%) is the major limit of this system and leaves room for improvement. MC ICP-MS operated in the edge mass resolution mode, applying bracketing for correction of IIF, provided isotope ratio values with the highest quality (relative combined measurement uncertainty: 0.02%; deviation from the certified value: <0.002%). PMID:27812369

  17. Study of fast electron generation using multi beam of LFEX-class laser

    International Nuclear Information System (INIS)

    Hata, M; Nagatomo, H; Sakagami, H; Johzaki, T; Sentoku, Y

    2016-01-01

    Fast Ignition Realization Experiment project phase-I (FIREX-I) is being performed at Institute of Laser Engineering, Osaka University. In this project, the four-beam bundled high-energy Petawatt laser (LFEX) is being operated. LFEX laser provides great multi-beam irradiation flexibility, with the possibility of arrange the pulses in temporal sequence, spatially separate them in distinct spots of focus them in a single spot. In this paper, we study the two- beam interference effects on high-intensity picosecond laser-plasma interaction (LPI) by twodimensional relativistic Particle-In-Cell simulations. The interference causes surface perturbation, which enhances laser absorption and underdense plasma generation, increasing the accelerated electron number and their slope temperature. The laser-to-electron energy conversion efficiency for two-beam interference case is suitable for Fast Ignition (FI) compared to the single beam case, but the increment of fast electron divergence leads to lower energy coupling. To optimize the target design for FI, these interference effects should be taken into consideration. (paper)

  18. Conceptual core designs for a 1200 MWe sodium cooled fast reactor

    International Nuclear Information System (INIS)

    Joo, H. K.; Lee, K. B.; Yoo, J. W.; Kim, Y. I.

    2008-01-01

    The conceptual core design for a 1200 MWe sodium cooled fast reactor is being developed under the framework of the Gen-IV SFR development program. To this end, three core concepts have been tested during the development of a core concept: a core with an enrichment split fuel, a core with a single-enrichment fuel with a region-wise varying clad thickness, and a core with a single-enrichment fuel with non-fuel rods. In order to optimize a conceptual core configuration which satisfies the design targets, a sensitivity study of the core design parameters has been performed. Two core concepts, the core with an enrichment-split fuel and the core with a single-enrichment fuel with a region-wise varying clad thickness, have been proposed as the candidates of the conceptual core for a 1200 MWe sodium cooled fast reactor. The detailed core neutronic, fuel behavior, thermal, and safety analyses will be performed for the proposed candidate core concepts to finalize the core design concept. (authors)

  19. Frequency and Attitudes to Fast Food Consumption in Yasuj, Southwestern Iran

    Directory of Open Access Journals (Sweden)

    Seyed Mohammad Amin Rezaei

    2017-06-01

    Full Text Available Background: Nowadays, fast food consumption has increased dramatically in different societies leading to many diseases such as heart disease, diabetes, hypertension and other chronic diseases. This study aimed to investigate the frequency and attitude toward consumption of fast foods. Methods: Totally, 540 subjects aged 18-45 years old from Yasuj, southwestern Iran who referred to health centers were randomly enrolled. A questionnaire was used to collect demographic information and the attitude toward fast food consumption. Results: Totally, 304 (56.3% male and 236 (43.7% female were included. The consumption of fast food was 3 times per week among 23.5% of participants, 1-2 times per week in 45.6% of people, less than once a week in 28.4% of subjects and 2.2% never had fast food experience. 79.7% of consumers cited good taste as the main reason for consumption, 59.6% and 14.4% of them reported fast preparation and advertisement, respectively. Students and singles ate fast food more than others, 84.7% of fast food consumers used carbonated beverages with their fast food and 63.7% of them had fast foods as dinner. Conclusion: Fast food consumption has been extremely high and particularly more among students and youths in Yasuj that can be an alarm for health providers,. Therefore, providing the necessary education and training can promote awareness for the side effects of fast food consumption in the society.

  20. The Fast-Casual Conundrum: Fast-Casual Restaurant Entrées Are Higher in Calories than Fast Food.

    Science.gov (United States)

    Schoffman, Danielle E; Davidson, Charis R; Hales, Sarah B; Crimarco, Anthony E; Dahl, Alicia A; Turner-McGrievy, Gabrielle M

    2016-10-01

    Frequently eating fast food has been associated with consuming a diet high in calories, and there is a public perception that fast-casual restaurants (eg, Chipotle) are healthier than traditional fast food (eg, McDonald's). However, research has not examined whether fast-food entrées and fast-casual entrées differ in calorie content. The purpose of this study was to determine whether the caloric content of entrées at fast-food restaurants differed from that found at fast-casual restaurants. This study was a cross-sectional analysis of secondary data. Calorie information from 2014 for lunch and dinner entrées for fast-food and fast-casual restaurants was downloaded from the MenuStat database. Mean calories per entrée between fast-food restaurants and fast-casual restaurants and the proportion of restaurant entrées that fell into different calorie ranges were assessed. A t test was conducted to test the hypothesis that there was no difference between the average calories per entrée at fast-food and fast-casual restaurants. To examine the difference in distribution of entrées in different calorie ranges between fast-food and fast-casual restaurants, χ(2) tests were used. There were 34 fast-food and 28 fast-casual restaurants included in the analysis (n=3,193 entrées). Fast-casual entrées had significantly more calories per entrée (760±301 kcal) than fast-food entrées (561±268; Prestaurants to determine whether the energy content or nutrient density of full meals (ie, entrées with sides and drinks) differs between fast-casual restaurants and fast-food restaurants. Calorie-conscious consumers should consider the calorie content of entrée items before purchase, regardless of restaurant type. Copyright © 2016 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  1. MR imaging of articular cartilage in the ankle: comparison of available imaging sequences and methods of measurement in cadavers

    Energy Technology Data Exchange (ETDEWEB)

    Tan, T.C.F. [Department of Radiology, Veterans Administrative Medical Center, San Diego, CA (United States)]|[University of California Medical Center, San Diego, CA (United States)]|[Department of Radiology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan (Taiwan, Province of China); Wilcox, D.M. [Department of Radiology, Veterans Administrative Medical Center, San Diego, CA (United States)]|[University of California Medical Center, San Diego, CA (United States); Frank, L. [Department of Radiology, Veterans Administrative Medical Center, San Diego, CA (United States)]|[University of California Medical Center, San Diego, CA (United States); Shih, C. [Department of Radiology, Veterans Administrative Medical Center, San Diego, CA (United States)]|[University of California Medical Center, San Diego, CA (United States)]|[Department of Radiology, Veterans General Hospital-Taipei (Taiwan, Province of China); Trudell, D.J. [Department of Radiology, Veterans Administrative Medical Center, San Diego, CA (United States)]|[University of California Medical Center, San Diego, CA (United States); Sartoris, D.J. [Department of Radiology, Veterans Administrative Medical Center, San Diego, CA (United States)]|[University of California Medical Center, San Diego, CA (United States); Resnick, D. [Department of Radiology, Veterans Administrative Medical Center, San Diego, CA (United States)]|[University of California Medical Center, San Diego, CA (United States)

    1996-11-01

    Objective. To assess hyaline cartilage of cadaveric ankles using different magnetic resonance (MR) imaging techniques and various methods of measurement. Design and patients. Cartilage thicknesses of the talus and tibia were measured in ten cadaveric ankles by naked eye and by digitized image analysis from MR images of fat-suppressed T1-weighted gradient recalled (FS-SPGR), sequences and pulsed transfer saturation sequences with (FS-STS) and without fat-suppression (STS); these measurements were compared with those derived from direct inspection of cadaveric sections. The accuracy and precision errors were evaluated statistically for each imaging technique as well as measuring method. Contrast-to-noise ratios of cartilage versus joint fluid and marrow were compared for each of the imaging sequences. Results. Statistically, measurements from FS-SPGR images were associated with the smallest estimation error. Precision error of measurements derived from digitized image analysis was found to be smaller than that derived from naked eye measurements. Cartilage thickness measurements in images from STS and FS-STS sequences revealed larger errors in both accuracy and precision. Interobserver variance was larger in naked eye assessment of the cartilage. Contrast-to-noise ratio of cartilage versus joint fluid and marrow was higher with FS-SPGR than with FS-STS or STS sequences. Conclusion. Of the sequences and measurement techniques studied, the FS-SPGR sequence combined with the use of digitized image analysis provides the most accurate method for the assessment of ankle hyaline cartilage. (orig.). With 3 figs., 2 tabs.

  2. MR imaging of articular cartilage in the ankle: comparison of available imaging sequences and methods of measurement in cadavers

    International Nuclear Information System (INIS)

    Tan, T.C.F.; Wilcox, D.M.; Frank, L.; Shih, C.; Trudell, D.J.; Sartoris, D.J.; Resnick, D.

    1996-01-01

    Objective. To assess hyaline cartilage of cadaveric ankles using different magnetic resonance (MR) imaging techniques and various methods of measurement. Design and patients. Cartilage thicknesses of the talus and tibia were measured in ten cadaveric ankles by naked eye and by digitized image analysis from MR images of fat-suppressed T1-weighted gradient recalled (FS-SPGR), sequences and pulsed transfer saturation sequences with (FS-STS) and without fat-suppression (STS); these measurements were compared with those derived from direct inspection of cadaveric sections. The accuracy and precision errors were evaluated statistically for each imaging technique as well as measuring method. Contrast-to-noise ratios of cartilage versus joint fluid and marrow were compared for each of the imaging sequences. Results. Statistically, measurements from FS-SPGR images were associated with the smallest estimation error. Precision error of measurements derived from digitized image analysis was found to be smaller than that derived from naked eye measurements. Cartilage thickness measurements in images from STS and FS-STS sequences revealed larger errors in both accuracy and precision. Interobserver variance was larger in naked eye assessment of the cartilage. Contrast-to-noise ratio of cartilage versus joint fluid and marrow was higher with FS-SPGR than with FS-STS or STS sequences. Conclusion. Of the sequences and measurement techniques studied, the FS-SPGR sequence combined with the use of digitized image analysis provides the most accurate method for the assessment of ankle hyaline cartilage. (orig.). With 3 figs., 2 tabs

  3. 4 T MRI of chondrocalcinosis in combination with three-dimensional CT, radiography, and arthroscopy: a report of three cases

    International Nuclear Information System (INIS)

    Suan, J.C.; Chhem, R.K.; Gati, J.S.; Norley, C.J.; Holdsworth, D.W.

    2005-01-01

    To describe 4 T MRI techniques in imaging chondrocalcinosis within the knee and examine the results together with those demonstrated using three-dimensional (3D) computed tomography, conventional radiography, and arthroscopy. From a larger clinical imaging study of early osteoarthritis, knee arthroscopy patients were imaged using high-field MRI and high-resolution 3D CT prior to their surgery. Retrospective review of the imaging data diagnosed three patients with chondrocalcinosis. Fat-suppressed 3D spoiled gradient (3D SPGR) and two-dimensional fat-suppressed fast spin echo (FSE) imaging was performed at 4 T. The MR images, multi-planar reformatted CT (MPR-CT) and maximum intensity projection CT (MIP-CT) images, and radiographs were examined by a musculoskeletal radiologist for the presence and location of chondrocalcinosis. The findings from arthroscopy were also included. MRI showed 16 sites of punctate hypointense regions from 18 articular surfaces and five of six menisci with similar signal characteristics. Both meniscal chondrocalcinosis and meniscal tears were clearly visible using the 3D SPGR sequence. Only three sites were demonstrated to have calcification using MPR-CT and MIP-CT revealed an additional three. In articular cartilage surfaces showing surface disruption, arthroscopy demonstrated 11 sites with crystal deposition. Arthroscopy also revealed five menisci with calcification present. Our preliminary findings suggest that imaging chondrocalcinosis using spoiled gradient 4 T MRI is superior and complementary to the other imaging modalities in the detection of crystal deposition in both articular cartilage and menisci. (orig.)

  4. 4 T MRI of chondrocalcinosis in combination with three-dimensional CT, radiography, and arthroscopy: a report of three cases

    Energy Technology Data Exchange (ETDEWEB)

    Suan, J.C.; Chhem, R.K.; Gati, J.S.; Norley, C.J.; Holdsworth, D.W. [Robarts Research Institute, Imaging Research Laboratories, London, Ontario (Canada)

    2005-11-01

    To describe 4 T MRI techniques in imaging chondrocalcinosis within the knee and examine the results together with those demonstrated using three-dimensional (3D) computed tomography, conventional radiography, and arthroscopy. From a larger clinical imaging study of early osteoarthritis, knee arthroscopy patients were imaged using high-field MRI and high-resolution 3D CT prior to their surgery. Retrospective review of the imaging data diagnosed three patients with chondrocalcinosis. Fat-suppressed 3D spoiled gradient (3D SPGR) and two-dimensional fat-suppressed fast spin echo (FSE) imaging was performed at 4 T. The MR images, multi-planar reformatted CT (MPR-CT) and maximum intensity projection CT (MIP-CT) images, and radiographs were examined by a musculoskeletal radiologist for the presence and location of chondrocalcinosis. The findings from arthroscopy were also included. MRI showed 16 sites of punctate hypointense regions from 18 articular surfaces and five of six menisci with similar signal characteristics. Both meniscal chondrocalcinosis and meniscal tears were clearly visible using the 3D SPGR sequence. Only three sites were demonstrated to have calcification using MPR-CT and MIP-CT revealed an additional three. In articular cartilage surfaces showing surface disruption, arthroscopy demonstrated 11 sites with crystal deposition. Arthroscopy also revealed five menisci with calcification present. Our preliminary findings suggest that imaging chondrocalcinosis using spoiled gradient 4 T MRI is superior and complementary to the other imaging modalities in the detection of crystal deposition in both articular cartilage and menisci. (orig.)

  5. Automated Measurement of Fast Mitochondrial Transport in Neurons

    Directory of Open Access Journals (Sweden)

    Kyle eMiller

    2015-11-01

    Full Text Available There is a growing recognition that fast mitochondrial transport in neurons is disrupted in multiple neurological diseases and psychiatric disorders. However a major constraint in identifying novel therapeutics based on mitochondrial transport is that the large-scale analysis of fast transport is time consuming. Here we describe methodologies for the automated analysis of fast mitochondrial transport from data acquired using a robotic microscope. We focused on addressing questions of measurement precision, speed, reliably, workflow ease, statistical processing and presentation. We used optical flow and particle tracking algorithms, implemented in ImageJ, to measure mitochondrial movement in primary cultured cortical and hippocampal neurons. With it, we are able to generate complete descriptions of movement profiles in an automated fashion of hundred of thousands of mitochondria with a processing time of approximately one hour. We describe the calibration of the parameters of the tracking algorithms and demonstrate that they are capable of measuring the fast transport of a single mitochondrion. We then show that the methods are capable of reliably measuring the inhibition of fast mitochondria transport induced by the disruption of microtubules with the drug nocodazole in both hippocampal and cortical neurons. This work lays the foundation for future large-scale screens designed to identify compounds that modulate mitochondrial motility.

  6. fastBMA: scalable network inference and transitive reduction.

    Science.gov (United States)

    Hung, Ling-Hong; Shi, Kaiyuan; Wu, Migao; Young, William Chad; Raftery, Adrian E; Yeung, Ka Yee

    2017-10-01

    Inferring genetic networks from genome-wide expression data is extremely demanding computationally. We have developed fastBMA, a distributed, parallel, and scalable implementation of Bayesian model averaging (BMA) for this purpose. fastBMA also includes a computationally efficient module for eliminating redundant indirect edges in the network by mapping the transitive reduction to an easily solved shortest-path problem. We evaluated the performance of fastBMA on synthetic data and experimental genome-wide time series yeast and human datasets. When using a single CPU core, fastBMA is up to 100 times faster than the next fastest method, LASSO, with increased accuracy. It is a memory-efficient, parallel, and distributed application that scales to human genome-wide expression data. A 10 000-gene regulation network can be obtained in a matter of hours using a 32-core cloud cluster (2 nodes of 16 cores). fastBMA is a significant improvement over its predecessor ScanBMA. It is more accurate and orders of magnitude faster than other fast network inference methods such as the 1 based on LASSO. The improved scalability allows it to calculate networks from genome scale data in a reasonable time frame. The transitive reduction method can improve accuracy in denser networks. fastBMA is available as code (M.I.T. license) from GitHub (https://github.com/lhhunghimself/fastBMA), as part of the updated networkBMA Bioconductor package (https://www.bioconductor.org/packages/release/bioc/html/networkBMA.html) and as ready-to-deploy Docker images (https://hub.docker.com/r/biodepot/fastbma/). © The Authors 2017. Published by Oxford University Press.

  7. Prototype fast breeder reactor main options

    International Nuclear Information System (INIS)

    Bhoje, S.B.; Chellapandi, P.

    1996-01-01

    Fast reactor programme gets importance in the Indian energy market because of continuous growing demand of electricity and resources limited to only coal and FBR. India started its fast reactor programme with the construction of 40 MWt Fast Breeder Test Reactor (FBTR). The reactor attained its first criticality in October 1985. The reactor power will be raised to 40 MWt in near future. As a logical follow-up of FBTR, it was decided to build a prototype fast breeder reactor, PFBR. Considering significant effects of capital cost and construction period on economy, systematic efforts are made to reduce the same. The number of primary and secondary sodium loops and components have been reduced. Sodium coolant, pool type concept, oxide fuel, 20% CW D9, SS 316 LN and modified 9Cr-1Mo steel (T91) materials have been selected for PFBR. Based on the operating experience, the integrity of the high temperature components including fuel and cost optimization aspects, the plant temperatures are recommended. Steam temperature of 763 K at 16.6 MPa and a single TG of 500 MWe gross output have been decided. PFBR will be located at Kalpakkam site on the coast of Bay of Bengal. The plant life is designed for 30 y and 75% load factor. In this paper the justifications for the main options chosen are given in brief. (author). 2 figs, 2 tabs

  8. ORIGINAL ARTICLES Back injuries in young fast bowlers - a ...

    African Journals Online (AJOL)

    Objective. To demonstrate the efficacy of various radiological diagnostic modalities in assessing lower back pain in young fast bowlers. Methods. Ten cricketers who presented to either a physiotherapist or a doctor with suspected spondylolysis underwent an X-ray, a single photon emission computed tomography (SPECT) ...

  9. Characterization of a time-resolved non-contact scanning diffuse optical imaging system exploiting fast-gated single-photon avalanche diode detection

    Energy Technology Data Exchange (ETDEWEB)

    Di Sieno, Laura, E-mail: laura.disieno@polimi.it; Dalla Mora, Alberto; Contini, Davide [Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); Wabnitz, Heidrun; Macdonald, Rainer [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin (Germany); Pifferi, Antonio [Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Mazurenka, Mikhail [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin (Germany); Hannoversches Zentrum für Optische Technologien, Nienburger Str. 17, 30167 Hannover (Germany); Hoshi, Yoko [Department of Biomedical Optics, Medical Photonics Research Center, Hamamatsu University School of Medicine, Hamamatsu 431-3192 (Japan); Boso, Gianluca; Tosi, Alberto [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); Becker, Wolfgang [Becker and Hickl GmbH, Nahmitzer Damm 30, 12277 Berlin (Germany); Martelli, Fabrizio [Dipartimento di Fisica e Astronomia dell’Università degli Studi di Firenze, Via G. Sansone 1, Sesto Fiorentino, Firenze 50019 (Italy)

    2016-03-15

    We present a system for non-contact time-resolved diffuse reflectance imaging, based on small source-detector distance and high dynamic range measurements utilizing a fast-gated single-photon avalanche diode. The system is suitable for imaging of diffusive media without any contact with the sample and with a spatial resolution of about 1 cm at 1 cm depth. In order to objectively assess its performances, we adopted two standardized protocols developed for time-domain brain imagers. The related tests included the recording of the instrument response function of the setup and the responsivity of its detection system. Moreover, by using liquid turbid phantoms with absorbing inclusions, depth-dependent contrast and contrast-to-noise ratio as well as lateral spatial resolution were measured. To illustrate the potentialities of the novel approach, the characteristics of the non-contact system are discussed and compared to those of a fiber-based brain imager.

  10. Characterization of a time-resolved non-contact scanning diffuse optical imaging system exploiting fast-gated single-photon avalanche diode detection

    International Nuclear Information System (INIS)

    Di Sieno, Laura; Dalla Mora, Alberto; Contini, Davide; Wabnitz, Heidrun; Macdonald, Rainer; Pifferi, Antonio; Mazurenka, Mikhail; Hoshi, Yoko; Boso, Gianluca; Tosi, Alberto; Becker, Wolfgang; Martelli, Fabrizio

    2016-01-01

    We present a system for non-contact time-resolved diffuse reflectance imaging, based on small source-detector distance and high dynamic range measurements utilizing a fast-gated single-photon avalanche diode. The system is suitable for imaging of diffusive media without any contact with the sample and with a spatial resolution of about 1 cm at 1 cm depth. In order to objectively assess its performances, we adopted two standardized protocols developed for time-domain brain imagers. The related tests included the recording of the instrument response function of the setup and the responsivity of its detection system. Moreover, by using liquid turbid phantoms with absorbing inclusions, depth-dependent contrast and contrast-to-noise ratio as well as lateral spatial resolution were measured. To illustrate the potentialities of the novel approach, the characteristics of the non-contact system are discussed and compared to those of a fiber-based brain imager.

  11. Fast neutron activation analysis using short-lived radionuclides

    International Nuclear Information System (INIS)

    Salma, I.; Zemplen-Papp, E.

    1993-01-01

    Fast neutron activation analysis experiments were performed to investigate the analytical possibilities and prospective utilization of short-lived activation products. A rapid pneumatic transfer system for use with neutron generators has been installed and applied for detecting radionuclides with a half-life from ∼300 ms to 20 s. The transport time for samples of total mass of 1-4 g is between 130 and 160 ms for pressurized air of 0.1-0.4 MPa. The reproducibility of transport times is less than 2%. The employed method of correcting time-dependent counting losses is based on the virtual pulse generator principle. The measuring equipment consists of CAMAC modules and a special gating circuit. Typical time distributions of counting losses are presented. The same 14 elements were studied by the conventional activation method (single irradiation and single counting) by both a typical pneumatic transport system (run time 3 s) and the fast pneumatic transport facility. Furthermore, the influence of the cyclic activation technique on the elemental sensitivities was investigated. (author) 15 refs.; 5 figs.; 3 tabs

  12. Fast CsI-phoswich detector

    International Nuclear Information System (INIS)

    Langenbrunner, J.R.

    1996-01-01

    An improved phoswich radiation detector used pure CsI crystal and a fast plastic scintillator and a single photomultiplier tube. The plastic is arranged to receive incident radiation, and that which passed through then strikes the CsI crystal. Scintillation light from both the plastic and CsI crystal are applied to the photomultiplier tube, with the light from the plastic passing through the crystal without absorption therein. Electronics are provided for analyzing the output of the photomultiplier tube to discriminate responses due to the plastic and the CsI crystal, through short gate and long gate integration, to produce results which are indicative of the characteristics of the different types of incident radiation, even in the presence of large amounts of radiation. The phoswich detector has excellent timing resolution. The scintillators of the CsI- phoswich were chosen for their fast risetimes, of about 3 ns for NE102A, and 30 ns for the pure CsI. 5 figs

  13. The Role of Fast Carrier Dynamics in SOA Based Devices

    DEFF Research Database (Denmark)

    Mørk, Jesper; Berg, Tommy Winther; Nielsen, Mads Lønstrup

    2004-01-01

    and the properties of schemes relying on cross-gain as well as cross-phase modulation are discussed. The possible benefits of using SOAs with quantum dot active regions are theoretically analyzed. The bandfilling characteristics and the presence of fast capture processes may allow to reach bitrates in excess of 100......We describe the characteristics of all-optical switching schemes based on semiconductor optical amplifiers (SOAs), with particular emphasis on the role of the fast carrier dynamics. The SOA response to a single short pulse as well as to a data-modulated pulse train is investigated...

  14. Fast weighted centroid algorithm for single particle localization near the information limit.

    Science.gov (United States)

    Fish, Jeremie; Scrimgeour, Jan

    2015-07-10

    A simple weighting scheme that enhances the localization precision of center of mass calculations for radially symmetric intensity distributions is presented. The algorithm effectively removes the biasing that is common in such center of mass calculations. Localization precision compares favorably with other localization algorithms used in super-resolution microscopy and particle tracking, while significantly reducing the processing time and memory usage. We expect that the algorithm presented will be of significant utility when fast computationally lightweight particle localization or tracking is desired.

  15. Fast Convolution Module (Fast Convolution Module)

    National Research Council Canada - National Science Library

    Bierens, L

    1997-01-01

    This report describes the design and realisation of a real-time range azimuth compression module, the so-called 'Fast Convolution Module', based on the fast convolution algorithm developed at TNO-FEL...

  16. A fast chopper for the Fermilab High Intensity Neutrino Source (HINS)

    Energy Technology Data Exchange (ETDEWEB)

    Madrak, R.; Wildman, D.; /Fermilab; Dymokde-Bradshaw, A.; Hares, J.; Kellett, P.

    2008-10-01

    A fast chopper capable of kicking single 2.5 MeV H-bunches spaced at 325 MHz, at rates greater than 50 MHz is needed for the Fermilab High Intensity Neutrino Source (HINS) [1]. Four 1.2 kV fast pulsers, designed and manufactured by Kentech Instruments Ltd., will drive a 0.5 m long meander made from a copper plated ceramic composite. Test results showing pulses from the first 1.2 kV pulser and meander results will be presented.

  17. Elemental analysis of fertilizer by fast neutron activation

    International Nuclear Information System (INIS)

    Bodart, F.; Deconninck, G.

    1977-01-01

    A simple and accurate technique has been developed to analyse commercial fertilizers for phosphorus, potassium, chlorine, magnesium and silicon. The method is based on fast-neutron activation using a neutron flux of 2x10 11 neutrons/second. The optimum analytical conditions are tabulated. After irradiation, the sample is measured on a conventional counting system including a Ge(Li) detector (10% efficiency and 2 keV resolution for 60 Co) and a multichannel analyser. Monitor foils radioactivity are measured separately at the same time with a 2''x2''NaI detector coupled with a single channel analyser and a scaler. Fast neutron activation has proved to be a fast, simple, reliable and low cost analytical technique for the determination of phosphorus, silicon, potassium, magnesium and chlorine in fertilizers. Not less than five phosphorus determinations are possible in one hour, while two potassium, magnesium and chlorine determinations are made at the same time. (T.G.)

  18. Parameter Optimization for Quantitative Signal-Concentration Mapping Using Spoiled Gradient Echo MRI

    Directory of Open Access Journals (Sweden)

    Gasser Hathout

    2012-01-01

    Full Text Available Rationale and Objectives. Accurate signal to tracer concentration maps are critical to quantitative MRI. The purpose of this study was to evaluate and optimize spoiled gradient echo (SPGR MR sequences for the use of gadolinium (Gd-DTPA as a kinetic tracer. Methods. Water-gadolinium phantoms were constructed for a physiologic range of gadolinium concentrations. Observed and calculated SPGR signal to concentration curves were generated. Using a percentage error determination, optimal pulse parameters for signal to concentration mapping were obtained. Results. The accuracy of the SPGR equation is a function of the chosen MR pulse parameters, particularly the time to repetition (TR and the flip angle (FA. At all experimental values of TR, increasing FA decreases the ratio between observed and calculated signals. Conversely, for a constant FA, increasing TR increases this ratio. Using optimized pulse parameter sets, it is possible to achieve excellent accuracy (approximately 5% over a physiologic range of concentration tracer concentrations. Conclusion. Optimal pulse parameter sets exist and their use is essential for deriving accurate signal to concentration curves in quantitative MRI.

  19. Pharmacokinetics and bioavailability of oxycodone and acetaminophen following single-dose administration of MNK-795, a dual-layer biphasic IR/ER combination formulation, under fed and fasted conditions

    Directory of Open Access Journals (Sweden)

    Devarakonda K

    2014-08-01

    Full Text Available Krishna Devarakonda,1 Terri Morton,1 Rachel Margulis,2 Michael Giuliani,3 Thomas Barrett4 1Clinical Pharmacology and Pharmacokinetics, 2Clinical Operations, 3Research and Development, 4Clinical Affairs, Mallinckrodt Inc., Hazelwood, MO, USA Background: XARTEMIS™ XR (formerly MNK-795 is a combination oxycodone (OC and acetaminophen (APAP analgesic with both immediate-release and extended-release (ER components (ER OC/APAP. The tablets are designed with gastric-retentive ER oral delivery technology that releases the ER component at a controlled rate in the upper gastrointestinal tract. Because consumption of food has demonstrated an impact on the pharmacokinetics (PK of some marketed products using gastric-retentive ER oral delivery technology, a characterization of the effects of fed (high- and low-fat diets versus fasted conditions on the PK of ER OC/APAP was performed. Methods: This Phase I study used an open-label randomized single-dose three-period six-sequence crossover single-center design. Healthy adult participants (n=48 were randomized to receive two tablets of ER OC/APAP under three conditions: following a high-fat meal; following a low-fat meal; and fasted. Plasma concentration versus time data from predose throughout designated times up to 48 hours postdose was used to estimate the PK parameters of oxycodone and APAP. Results: Thirty-one participants completed all three treatment periods. Both oxycodone and APAP were rapidly absorbed under fasted conditions. Total oxycodone and APAP exposures (area under the plasma drug concentration-time curve [AUC] from ER OC/APAP were not significantly affected by food, and minimal changes to maximum observed plasma concentration for oxycodone and APAP were also noted. However, food marginally delayed the time to maximum observed plasma concentration of oxycodone and APAP. There was no indication that tolerability was affected by food. Conclusion: The findings from this study suggest that ER OC

  20. Differential Single-Capture Cross Sections for Fast Alpha–Helium Collisions

    International Nuclear Information System (INIS)

    Ghanbari-Adivi, Ebrahim; Ghavaminia, Hoda

    2014-01-01

    A four-body theoretical study of the single charge transfer process in collision of energetic alpha ions with helium atoms in their ground states is presented. The model utilizes the Coulomb–Born distorted wave approximation with correct boundary conditions to calculate the single-electron capture differential and integral cross sections. The influence of the dynamic and static electron correlations on the capture probability is investigated. The results of the calculations are compared with the recent experimental measurements for differential cross sections and with the other theoretical manipulations. The results for scattering at extreme forward angles are in good agreement with the experimental measurements, but in other scattering angles the agreement is poor. However, the present four-body results for integral cross sections are in excellent agreement with the experimental data. (author)

  1. Analysis of very fast transients in layer-type transformer windings

    NARCIS (Netherlands)

    Popov, M.; Sluis, van der L.; Smeets, R.; Lopez Roldan, J.

    2007-01-01

    This paper deals with the measurement, modeling, and simulation of very fast transient overvoltages in layer-type distribution transformer windings. Measurements were performed by applying a step impulse with 50-ns rise time on a single-phase test transformer equipped with measuring points along the

  2. Fast T1 mapping of the brain at high field using Look-Locker and fast imaging.

    Science.gov (United States)

    Jiang, Ke; Zhu, Yanjie; Jia, Sen; Wu, Yin; Liu, Xin; Chung, Yiu-Cho

    2017-02-01

    This study aims to develop and evaluate a new method for fast high resolution T1 mapping of the brain based on the Look-Locker technique. Single-shot turboflash sequence with high temporal acceleration is used to sample the recovery of inverted magnetization. Multi-slice interleaved acquisition within one inversion slab is used to reduce the number of inversion pulses and hence SAR. Accuracy of the proposed method was studied using simulation and validated in phantoms. It was then evaluated in healthy volunteers and stroke patients. In-vivo results were compared to values obtained by inversion recovery fast spin echo (IR-FSE) and literatures. With the new method, T 1 values in phantom experiments agreed with reference values with median error map was acquired in 3.35s and the T1 maps of the whole brain were acquired in 2min with two-slice interleaving, with a spatial resolution of 1.1×1.1×4mm 3 . The T 1 values obtained were comparable to those measured with IR-FSE and those reported in literatures. These results demonstrated the feasibility of the proposed method for fast T1 mapping of the brain in both healthy volunteers and stroke patients at 3T. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Developmental validation of the PowerPlex(®) ESI 16/17 Fast and PowerPlex(®) ESX 16/17 Fast Systems.

    Science.gov (United States)

    McLaren, Robert S; Bourdeau-Heller, Jeanne; Patel, Jaynish; Thompson, Jonelle M; Pagram, Jenny; Loake, Thomas; Beesley, David; Pirttimaa, Markus; Hill, Carolyn R; Duewer, David L; Kline, Margaret C; Butler, John M; Storts, Douglas R

    2014-11-01

    The PowerPlex(®) ESI 16 Fast, ESI 17 Fast, ESX 16 Fast, and ESX 17 Fast Systems represent faster cycling versions (50min or less) of the PowerPlex(®) ESI and ESX Systems released by Promega in 2009 to accommodate the ENFSI and EDNAP groups' call for new STR multiplexes for Europe. In addition to amplification of purified DNA samples, these new faster cycling systems allow for direct amplification from single-source blood and buccal samples deposited on FTA(®) and nonFTA paper as well as from SwabSolution™ extracts of buccal swabs without the need for purification and quantitation. There are no changes to the autosomal primer pair sequences in the PowerPlex(®) ESI Fast and ESX Fast Systems compared to the original multiplexes, and full concordance at all autosomal loci and amelogenin was observed with data generated previously with the original PowerPlex(®) ESI and ESX Systems. This paper describes the developmental validation study performed on these new fast systems following guidelines issued by the Scientific Working Group on DNA Analysis Methods (SWGDAM) and those of the DNA Advisory Board (DAB). Validation data demonstrate that these systems are sensitive for detecting low levels of DNA while also being capable of generating robust profiles from the high amount of input DNA present in direct-amplification samples. These systems are also tolerant to both high concentrations of PCR inhibitors as well as to slight variations in the final concentration of master mix and primer pair present in the amplification reaction that might be encountered due to pipetting error. The results of this validation study demonstrate that these systems may be used on multiple thermal cyclers and capillary electrophoresis platforms. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  4. Study Protocol: Phase III single-blinded fast-track pragmatic randomised controlled trial of a complex intervention for breathlessness in advanced disease

    Directory of Open Access Journals (Sweden)

    Brafman-Kennedy Barbara

    2011-05-01

    Full Text Available Abstract Background Breathlessness in advanced disease causes significant distress to patients and carers and presents management challenges to health care professionals. The Breathlessness Intervention Service (BIS seeks to improve the care of breathless patients with advanced disease (regardless of cause through the use of evidence-based practice and working with other healthcare providers. BIS delivers a complex intervention (of non-pharmacological and pharmacological treatments via a multi-professional team. BIS is being continuously developed and its impact evaluated using the MRC's framework for complex interventions (PreClinical, Phase I and Phase II completed. This paper presents the protocol for Phase III. Methods/Design Phase III comprises a pragmatic, fast-track, single-blind randomised controlled trial of BIS versus standard care. Due to differing disease trajectories, the service uses two broad service models: one for patients with malignant disease (intervention delivered over two weeks and one for patients with non-malignant disease (intervention delivered over four weeks. The Phase III trial therefore consists of two sub-protocols: one for patients with malignant conditions (four week protocol and one for patients with non-malignant conditions (eight week protocol. Mixed method interviews are conducted with patients and their lay carers at three to five measurement points depending on randomisation and sub-protocol. Qualitative interviews are conducted with referring and non-referring health care professionals (malignant disease protocol only. The primary outcome measure is 'patient distress due to breathlessness' measured on a numerical rating scale (0-10. The trial includes economic evaluation. Analysis will be on an intention to treat basis. Discussion This is the first evaluation of a breathlessness intervention for advanced disease to have followed the MRC framework and one of the first palliative care trials to use fast

  5. Comparative bioavailability and tolerability of a single 20-mg dose of two fluoxetine hydrochloride dispersible tablet formulations in fasting, healthy Chinese male volunteers: an open-label, randomized-sequence, two-period crossover study.

    Science.gov (United States)

    Shi, Shaojun; Liu, Yani; Wu, Jianhong; Li, Zhongfang; Zhao, Yan; Zhong, Dafang; Zeng, Fandian

    2010-10-01

    The proprietary formulation of fluoxetine hydrochloride is an antidepressant of the selective serotonin reuptake inhibitor class. Pharmacokinetic studies investigating the bioequivalence of generic and branded formulations are needed to market generic fluoxetine in China. The aim of this study was to compare the bioavailability and tolerability of the proposed generic formulation with the established reference formulation of fluoxetine hydrochloride 20 mg in a fasting, healthy Chinese male population. This 10-week, open-label, randomized-sequence, single-dose, 2-period crossover study was conducted in healthy native Han Chinese male volunteers. Eligible subjects were randomly assigned in a 1:1 ratio to receive a single 20-mg dose of the test or reference formulation, followed by a 35-day washout period and administration of the alternate formulation. Doses were administered after a 12-hour overnight fast. For analysis of pharmacokinetic properties (including C(max), T(max), AUC(0-t), AUC(0-∞), and t(½)), blood samples were obtained over a 672-hour period after dosing. Plasma concentrations of fluoxetine and its active metabolite, norfluoxetine, were analyzed using a validated LC-MS/MS method. The formulations were to be considered bioequivalent if the ln-transformed ratios (test/ reference) of C(max) and AUC were within the predetermined bioequivalence range of 80% to 125%, as established by the US Food and Drug Administration, and if the P values were fasting, healthy Chinese male volunteers. Both formulations appeared to be well tolerated. Copyright © 2010 Excerpta Medica Inc. All rights reserved.

  6. A fast photo-counter with multi-level buffers

    International Nuclear Information System (INIS)

    Peng Hu; Zhou Peiling; Yao Kun; Guo Guangcan

    1992-01-01

    Digital Photon Correlator (DPC) is composed of a Photo-counter and a data processing unit. The performance of Photo-counter in data acquisition system has a direct influence on data processing. The Photo-counter with fast carry designed here has multi-level buffers. Photon pulses can be correctly and dynamically recorded by the Photo-counter and processed by a single chip computer

  7. Spectroscopic study of fast-neutron-irradiated chromatin

    International Nuclear Information System (INIS)

    Radu, L.; Gazdaru, D.; Constantinescu, B.

    2004-01-01

    The effects produced by fast neutrons (0-100 Gy) on chromatin structure were analyzed by (i) [ 1 H]-NMR spectroscopy, (ii) time resolved spectroscopy, and (iii) fluorescence resonance energy transfer (FRET). Two types of chromatin were tested: (i) a chromatin from a normal tissue (liver of Wistar rats) and (ii) a chromatin from a tumoral tissue (Guerin limphotrope epithelioma, a rat solid tumor). The fast-neutron action on chromatin determines greater values of the [ 1 H]-NMR transverse relaxation time, indicating a more injured structure. Time-resolved fluorescence measurements show that the relative contribution of the excited state lifetime of bound ethidium bromide to chromatin DNA diminishes with increasing irradiation doses. This reflects the damage that occurs in DNA structure: production of single- and double-strand breaks due to sugar and base modifications. By the FRET method, the distance between dansyl chloride and acridine orange coupled at chromatin was determined. This distance increases upon fast-neutron action. The radiosensitivity of the tumor tissue chromatin seems higher than that of the normal tissue chromatin, probably because of its higher (loose) euchromatin/(compact) heterochromatin ratio. As the values of the physical parameters analyzed are specific for a determined dose, the establishment of these parameters may constitute a criterion for the microdosimetry of chromatin radiolesions produced by fast neutrons. (author)

  8. Spectroscopic study of fast-neutron-irradiated chromatin

    Energy Technology Data Exchange (ETDEWEB)

    Radu, L. [V. Babes National Inst., Dept. of Molecular Genetics, Bucharest (Romania)]. E-mail: serbanradu@pcnet.ro; Gazdaru, D. [Bucharest Univ., Dept. of Biophysics, Physics Faculty, Bucharest (Romania); Constantinescu, B. [H. Hulubei National Inst., Dept. of Cyclotron, Bucharest (Romania)

    2004-02-01

    The effects produced by fast neutrons (0-100 Gy) on chromatin structure were analyzed by (i) [{sup 1}H]-NMR spectroscopy, (ii) time resolved spectroscopy, and (iii) fluorescence resonance energy transfer (FRET). Two types of chromatin were tested: (i) a chromatin from a normal tissue (liver of Wistar rats) and (ii) a chromatin from a tumoral tissue (Guerin limphotrope epithelioma, a rat solid tumor). The fast-neutron action on chromatin determines greater values of the [{sup 1}H]-NMR transverse relaxation time, indicating a more injured structure. Time-resolved fluorescence measurements show that the relative contribution of the excited state lifetime of bound ethidium bromide to chromatin DNA diminishes with increasing irradiation doses. This reflects the damage that occurs in DNA structure: production of single- and double-strand breaks due to sugar and base modifications. By the FRET method, the distance between dansyl chloride and acridine orange coupled at chromatin was determined. This distance increases upon fast-neutron action. The radiosensitivity of the tumor tissue chromatin seems higher than that of the normal tissue chromatin, probably because of its higher (loose) euchromatin/(compact) heterochromatin ratio. As the values of the physical parameters analyzed are specific for a determined dose, the establishment of these parameters may constitute a criterion for the microdosimetry of chromatin radiolesions produced by fast neutrons. (author)

  9. Fast methods for analysis of neurotransmitters from single cell and monitoring their releases in central nervous system by capillary electrophoresis, fluorescence microscopy and luminescence imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ziqiang [Iowa State Univ., Ames, IA (United States)

    1999-12-10

    Fast methods for separation and detection of important neurotransmitters and the releases in central nervous system (CNS) were developed. Enzyme based immunoassay combined with capillary electrophoresis was used to analyze the contents of amino acid neurotransmitters from single neuron cells. The release of amino acid neurotransmitters from neuron cultures was monitored by laser induced fluorescence imaging method. The release and signal transduction of adenosine triphosphate (ATP) in CNS was studied with sensitive luminescence imaging method. A new dual-enzyme on-column reaction method combined with capillary electrophoresis has been developed for determining the glutamate content in single cells. Detection was based on monitoring the laser-induced fluorescence of the reaction product NADH, and the measured fluorescence intensity was related to the concentration of glutamate in each cell. The detection limit of glutamate is down to 10-8 M level, which is 1 order of magnitude lower than the previously reported detection limit based on similar detection methods. The mass detection limit of a few attomoles is far superior to that of any other reports. Selectivity for glutamate is excellent over most of amino acids. The glutamate content in single human erythrocyte and baby rat brain neurons were determined with this method and results agreed well with literature values.

  10. Fast imaging of live organisms with sculpted light sheets

    Science.gov (United States)

    Chmielewski, Aleksander K.; Kyrsting, Anders; Mahou, Pierre; Wayland, Matthew T.; Muresan, Leila; Evers, Jan Felix; Kaminski, Clemens F.

    2015-04-01

    Light-sheet microscopy is an increasingly popular technique in the life sciences due to its fast 3D imaging capability of fluorescent samples with low photo toxicity compared to confocal methods. In this work we present a new, fast, flexible and simple to implement method to optimize the illumination light-sheet to the requirement at hand. A telescope composed of two electrically tuneable lenses enables us to define thickness and position of the light-sheet independently but accurately within milliseconds, and therefore optimize image quality of the features of interest interactively. We demonstrated the practical benefit of this technique by 1) assembling large field of views from tiled single exposure each with individually optimized illumination settings; 2) sculpting the light-sheet to trace complex sample shapes within single exposures. This technique proved compatible with confocal line scanning detection, further improving image contrast and resolution. Finally, we determined the effect of light-sheet optimization in the context of scattering tissue, devising procedures for balancing image quality, field of view and acquisition speed.

  11. Studies on fast wave current drive in the JAERI tokamaks

    International Nuclear Information System (INIS)

    Kimura, H.; Yamamoto, T.; Fujii, T.; Kawashima, H.; Tamai, H.; Saigusa, M.; Imai, T.; Hamamatsu, K.; Fukuyama, A.

    1991-01-01

    Fast wave electron heating experiment (FWEH) on JFT-2M and JT-60 and analysis of fast wave current drive (FWCD) ability on JT-60U are presented. In the JFT-2M, absorption of fast waves have been investigated by using a phased four-loop antenna array. The absorption of the fast waves has been studied for various plasma parameters by using combination of other additional heating methods such as electron cyclotron heating (ECH) and ion cyclotron heating. It is shown that the absorption efficiency estimated from various methods well correlates with one calculated theoretically in single pass damping. Interaction of the fast waves with fast electrons in combination with ECH has been examined through the measurement of non-thermal electron cyclotron emission (ECE). The observed ECE during FWEH is well explained by the theoretical model, which indicates generation of the appreciable energetic fast electrons by the fast waves. New four-loop array antennas have been employed to improve the absorption of unidirectionally-propagating waves. Characteristics of antenna loading resistance can be reproduced by a coupling calculation code. In JT-60, FWEH experiment in combination with lower hybrid current drive was performed. Power absorption efficiency of fast wave is substantially improved in combination with LHCD of relatively low power for both phasing modes. Bulk electron heating is observed with high-k // mode and coupling with fast electron is confirmed in hard X-ray emission with low-k // mode. The results are consistent with theoretical prediction based on 1.D full wave code. Synergetic effects between FWEH and LHCD are found. Coupling calculation indicates that eight-loop antenna is favourable for keeping high directivity in the required N // -range. Current drive efficiency is calculated with 1-D full wave code including trapped particle effects and higher harmonic ion cyclotron damping

  12. European Banking with a Single Currency

    OpenAIRE

    Jean Dermine

    1996-01-01

    At the Madrid summit in December 1995, the EU heads of state or government endorsed a three-phase plan for the introduction of the single currency. The purpose of the paper is to identify how, besides an obvious fall in revenue from intra-European currencies trading, a single currency will alter fundamentally and permanently European banking markets. A common currency will likely change the sources of competitive advantage in various markets such as those of government bonds and their fast gr...

  13. Characteristics evaluation of stilbene single crystal grown by vertical bridgman technique

    International Nuclear Information System (INIS)

    Jo, Kwang Ho

    2012-02-01

    As the nature of organic scintillator, stilbene single crystal's decay time is only a couple of nano seconds, which makes it suitable for fast neutron detection. However, the entire amount of stilbene single crystal being used relies on import currently. As the necessity of fast neutron detection equipment such as KSTAR and Sodium-cooled Fast Reactor system increases, the goal is to have our own domestic technology through the growth of stilbene single crystal. The emission wavelength of grown stilbene single crystal is confirmed, and the property of grown stilbene single crystal is assessed compared to commercial stilbene (Ukraine ISMA research center) through gamma ray and neutron tests. In this research, we have grown stilbenes through Bridgman technique, and obtained three stilbenes out of two amples. (Two ones of Φ 30 mm x 15 mm, and Φ 40 mm x 17 mm from the first ample, and size of Φ 25 mm x 13 mm from the other) The grown stilbene's emission wavelength and inherent property of stilbene are confirmed. As the result of gamma ray test, we have confirmed linearity of grown stilbene's scintillator, and the relative light yield ratio is proven 101% efficiency to reference stilbene. Neutron detection efficiency of the three stilbenes amounts to 80% of reference stilbene, and FOM of them is 108% efficiency to reference stilbene's one. Although Ukraine ISMA research center still holds a dominant position with world-class efficiency and performance of its stilbene, we expect to produce a better stilbene with our domestic technology development. Through this, fast neutron detection technique can be obtained, which opens up an opportunity to be used not only in neutron monitoring system in nuclear fusion reactor, but also in alternative measurement technique as the unit price of He-3 increases recently

  14. Value of MR cisternography using three-dimensional half-fourier single-shot fast spin-echo sequences in the diagnosis of diseases related to cranial nerves VII and VIII

    Energy Technology Data Exchange (ETDEWEB)

    Yamakami, Norio [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1999-05-01

    The purpose of this study was to evaluate the value of MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences in the diagnosis of diseasea related to cranial nerves VII and VIII. With a 0.5-T imager, the most appropriate setting of echo time and section thickness was first assessed in five volunteers. This resulted in echo time of 250 msec and section thickness of 2 mm as the most effective parameters. Second, using echo time of 120 msec and section thickness of 1.5 mm that were available from the beginning of this study, the demonstration of four nerves within the audistory canal was assessed in seven volunteers. In all of the volunteers, the facial, cochlear, and vestibular nerves were determined with demonstration of each of superior and inferior vestibular nerves in four of them. Next, MR cisternography using the same echo time and section thickness was applied in 368 patients with suspicion of acoustic neurinoma and 14 with hemifacial spasm. In 28 of the 368 patients, MR cisternograms depicted an acoustic neurinoma that was confirmed on postcontrast T1-weighted images. Meanwhile, in five of the 14 patients with hemifacial spasm, MR cisternograms revealed a vessel compressing the root exit zone of the affected facial nerve. It is concluded that MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences can be a useful means for demonstrating nerves within the auditory nerve as well as for the screening of acoustic neurionoma. (author)

  15. Value of MR cisternography using three-dimensional half-fourier single-shot fast spin-echo sequences in the diagnosis of diseases related to cranial nerves VII and VIII

    International Nuclear Information System (INIS)

    Yamakami, Norio

    1999-01-01

    The purpose of this study was to evaluate the value of MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences in the diagnosis of diseasea related to cranial nerves VII and VIII. With a 0.5-T imager, the most appropriate setting of echo time and section thickness was first assessed in five volunteers. This resulted in echo time of 250 msec and section thickness of 2 mm as the most effective parameters. Second, using echo time of 120 msec and section thickness of 1.5 mm that were available from the beginning of this study, the demonstration of four nerves within the audistory canal was assessed in seven volunteers. In all of the volunteers, the facial, cochlear, and vestibular nerves were determined with demonstration of each of superior and inferior vestibular nerves in four of them. Next, MR cisternography using the same echo time and section thickness was applied in 368 patients with suspicion of acoustic neurinoma and 14 with hemifacial spasm. In 28 of the 368 patients, MR cisternograms depicted an acoustic neurinoma that was confirmed on postcontrast T1-weighted images. Meanwhile, in five of the 14 patients with hemifacial spasm, MR cisternograms revealed a vessel compressing the root exit zone of the affected facial nerve. It is concluded that MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences can be a useful means for demonstrating nerves within the auditory nerve as well as for the screening of acoustic neurionoma. (author)

  16. Fasting and exercise increase plasma cannabinoid levels in THC pre-treated rats: an examination of behavioural consequences.

    Science.gov (United States)

    Wong, Alexander; Keats, Kirily; Rooney, Kieron; Hicks, Callum; Allsop, David J; Arnold, Jonathon C; McGregor, Iain S

    2014-10-01

    Δ(9)-Tetrahydrocannabinol (THC), the main psychoactive constituent of cannabis, accumulates in fat tissue where it can remain for prolonged periods. Under conditions of increased fat utilisation, blood cannabinoid concentrations can increase. However, it is unclear whether this has behavioural consequences. Here, we examined whether rats pre-treated with multiple or single doses of THC followed by a washout would show elevated plasma cannabinoids and altered behaviour following fasting or exercise manipulations designed to increase fat utilisation. Behavioural impairment was measured as an inhibition of spontaneous locomotor activity or a failure to successfully complete a treadmill exercise session. Fat utilisation was indexed by plasma free fatty acid (FFA) levels with plasma concentrations of THC and its terminal metabolite (-)-11-nor-9-carboxy-∆(9)-tetrahydrocannabinol (THC-COOH) also measured. Rats given daily THC (10 mg/kg) for 5 days followed by a 4-day washout showed elevated plasma THC-COOH when fasted for 24 h relative to non-fasted controls. Fasted rats showed lower locomotor activity than controls suggesting a behavioural effect of fat-released THC. However, rats fasted for 20 h after a single 5-mg/kg THC injection did not show locomotor suppression, despite modestly elevated plasma THC-COOH. Rats pre-treated with THC (5 mg/kg) and exercised 20 h later also showed elevated plasma THC-COOH but did not differ from controls in their likelihood of completing 30 min of treadmill exercise. These results confirm that fasting and exercise can increase plasma cannabinoid levels. Behavioural consequences are more clearly observed with pre-treatment regimes involving repeated rather than single THC dosing.

  17. Developments of optical fast-gated imaging systems

    International Nuclear Information System (INIS)

    Koehler, H.A.; Kotecki, D.

    1984-08-01

    Several fast-gated imaging systems to measure ultra-fast single-transient data have been developed for time-resolved imaging of pulsed radiation sources. These systems were designed to achieve image recording times of 1 to 3 ms and dynamic ranges of >200:1 to produce large two-dimensional images (greater than or equal to 10 4 spatial points) of 1 to 2 ns exposure and small two-dimensional images (less than or equal to 200 spatial points) of less than or equal to 0.5 ns exposure. Both MCP intensified solid-state two-dimensional framing cameras and streak camera/solid-state camera systems were used; the framing camera system provides snap shots with high spatial resolution whereas the streak camera system provides for limited spatial points each with high temporal resolution. Applications of these systems include electron-beam, x-ray, gamma-ray, and neutron diagnostics. This report reviews the characteristics of the major components of fast-gated imaging systems developed at Lawrence Livermore National Laboratory. System performances are described in view of major experiments, and the diagnostic requirements of new experiments in atomic physics (x-ray lasers) and nuclear physics (fusion) are indicated

  18. Fast MR imaging for evaluating the pancreaticobiliary system

    International Nuclear Information System (INIS)

    Takehara, Yasuo

    1999-01-01

    Due to physiological movement clinical MR applications for abdominal organs got off to a very slow start compared to MR imaging of other organs. However, with recent cutting-edge hardware technologies such as high performance gradient systems and phased-array capability, as well as software innovations including short TR fast spoiled gradient recalled acquisition in the steady state (GRASS), snapshot imaging such as single shot fast spin echo sequence (SSFSE) and echo planar imaging (EPI), scan times have been further reduced to make breath-hold imaging clinically viable and to enable semi-fluoroscopic, kinematic imaging recognition. The elimination of physiological motion has contributed to the significant improvement in image quality, or more specifically, the physiological motion that had long been problematic has been turned into a source of physiological information about pancreaticobiliary pathologies. In this article, the author reviewed the current status of fast MR technologies for examining pancreaticobiliary pathologies, stressing the functional and physiological aspects of the corresponding anatomy. The technologies included secretin MRCP, which became a powerful tool when combined with kinematic imaging

  19. A fast ADC system for silicon μstrips readout

    International Nuclear Information System (INIS)

    Inzani, P.; Pedrini, D.; Sala, S.

    1986-01-01

    A new fast ADC module has been designed. It is part of a large readout system for a high resolution vertex detector consisting of 12 silicon microstrip planes with more than 8000 channels. The module employs a set of monolithic gated integrators on input (LeCroy MIQ 401) multiplexed on a single 8 bit FADC (Thompson EFX8308). A built-in preprocessing, performed through look up tables, accomplishes equalization and reduction of the data and makes high level trigger feasible. As an additional feature, fast histogramming of all the channels in parallel has been made possible with an internal memory. Special care has been paid to realize a low cost and low power consumption system

  20. Neighborhood fast food restaurants and fast food consumption: a national study.

    Science.gov (United States)

    Richardson, Andrea S; Boone-Heinonen, Janne; Popkin, Barry M; Gordon-Larsen, Penny

    2011-07-08

    Recent studies suggest that neighborhood fast food restaurant availability is related to greater obesity, yet few studies have investigated whether neighborhood fast food restaurant availability promotes fast food consumption. Our aim was to estimate the effect of neighborhood fast food availability on frequency of fast food consumption in a national sample of young adults, a population at high risk for obesity. We used national data from U.S. young adults enrolled in wave III (2001-02; ages 18-28) of the National Longitudinal Study of Adolescent Health (n = 13,150). Urbanicity-stratified multivariate negative binomial regression models were used to examine cross-sectional associations between neighborhood fast food availability and individual-level self-reported fast food consumption frequency, controlling for individual and neighborhood characteristics. In adjusted analysis, fast food availability was not associated with weekly frequency of fast food consumption in non-urban or low- or high-density urban areas. Policies aiming to reduce neighborhood availability as a means to reduce fast food consumption among young adults may be unsuccessful. Consideration of fast food outlets near school or workplace locations, factors specific to more or less urban settings, and the role of individual lifestyle attitudes and preferences are needed in future research.

  1. Neighborhood fast food restaurants and fast food consumption: A national study

    Directory of Open Access Journals (Sweden)

    Gordon-Larsen Penny

    2011-07-01

    Full Text Available Abstract Background Recent studies suggest that neighborhood fast food restaurant availability is related to greater obesity, yet few studies have investigated whether neighborhood fast food restaurant availability promotes fast food consumption. Our aim was to estimate the effect of neighborhood fast food availability on frequency of fast food consumption in a national sample of young adults, a population at high risk for obesity. Methods We used national data from U.S. young adults enrolled in wave III (2001-02; ages 18-28 of the National Longitudinal Study of Adolescent Health (n = 13,150. Urbanicity-stratified multivariate negative binomial regression models were used to examine cross-sectional associations between neighborhood fast food availability and individual-level self-reported fast food consumption frequency, controlling for individual and neighborhood characteristics. Results In adjusted analysis, fast food availability was not associated with weekly frequency of fast food consumption in non-urban or low- or high-density urban areas. Conclusions Policies aiming to reduce neighborhood availability as a means to reduce fast food consumption among young adults may be unsuccessful. Consideration of fast food outlets near school or workplace locations, factors specific to more or less urban settings, and the role of individual lifestyle attitudes and preferences are needed in future research.

  2. LIMITS ON THE EVENT RATES OF FAST RADIO TRANSIENTS FROM THE V-FASTR EXPERIMENT

    International Nuclear Information System (INIS)

    Wayth, Randall B.; Tingay, Steven J.; Deller, Adam T.; Brisken, Walter F.; Thompson, David R.; Wagstaff, Kiri L.; Majid, Walid A.

    2012-01-01

    We present the first results from the V-FASTR experiment, a commensal search for fast transient radio bursts using the Very Long Baseline Array (VLBA). V-FASTR is unique in that the widely spaced VLBA antennas provide a discriminant against non-astronomical signals and a mechanism for the localization and identification of events that is not possible with single dishes or short baseline interferometers. Thus, far V-FASTR has accumulated over 1300 hr of observation time with the VLBA, between 90 cm and 3 mm wavelength (327 MHz-86 GHz), providing the first limits on fast transient event rates at high radio frequencies (>1.4 GHz). V-FASTR has blindly detected bright individual pulses from seven known pulsars but has not detected any single-pulse events that would indicate high-redshift impulsive bursts of radio emission. At 1.4 GHz, V-FASTR puts limits on fast transient event rates comparable with the PALFA survey at the Arecibo telescope, but generally at lower sensitivities, and comparable to the 'fly's eye' survey at the Allen Telescope Array, but with less sky coverage. We also illustrate the likely performance of the Phase 1 SKA dish array for an incoherent fast transient search fashioned on V-FASTR.

  3. Fast neutron induced flux pinning in Tl-based high-Tc single crystals and thin films, highly textured tapes and melt-textured bulk 123-superconductors

    International Nuclear Information System (INIS)

    Brandstaetter, G.; Samadi Hosseinalli, G.; Kern, C.; Sauerzopf, F.M.; Schulz, G.W.; Straif, W.; Yang, X.; Weber, H.W.; Hu, Q.Y.

    1999-01-01

    Various compounds (TI-2223, TI-1223, TI-2212) as well as material forms (single crystals, thin films, ceramics, tapes) of TI-based high temperature superconductors were investigated by magnetic and transport techniques. TI-2223 has a very 'low lying' irreversibility line (H parallel e) and negligible critical current densities J c at 77 K. However, the irreversibility line shifts to higher fields and temperatures and J c is strongly enhanced, even at 77 K, after fast neutron irradiation. In contrast, the related TI-1223 compound has a much steeper irreversibility line (H parallel c) similar to that of Y-123. J c is significant up to 77 K, even in the unirradiated state, and can be largely improved by neutron irradiation. Transport measurements made on TI-1223 tapes still show much lower critical current densities. TI-2212 and Tl-2223 thin films have J c 's at 77 K, which are comparable to those of TI-1223 single crystals. Transport measurements on highly textured Bi-2223 tapes as well as flux profile measurements on Nd-123 bulk superconductors confirm the beneficial effects of neutron induced defects (collision cascades) for flux pinning. (author)

  4. Influence of food on pharmacokinetics of zolpidem from fast dissolving sublingual zolpidem tartrate tablets.

    Science.gov (United States)

    Greenblatt, David J; Harmatz, Jerold S; Singh, Nikhilesh N; Roth, Thomas; Harris, Stephen C; Kapil, Ram P

    2013-11-01

    Ingesting food can impact the pharmacokinetics of sedative-hypnotic drugs. A buffered zolpidem sublingual tablet (ZST) recently became available for the treatment of middle-of-the-night awakening. In this randomized, open-label, single-site study, the pharmacokinetic profile of ZST was evaluated when administered while fasting and following a standard high-fat meal (fed state). Healthy adults aged 18-64 years received a single morning dose of 3.5 mg ZST in the fed or fasting state. From 20 min to 3 h post-dose, zolpidem plasma levels were lower in the fed state compared to the fasting state. After 4 h post-dose (corresponding to "morning wake time"), higher zolpidem plasma levels were evident in the fed state. Area under the concentration-time curve (AUC) values for the 0-8 h interval were 160 ng/mL h in the fed state and 203 ng/mL h in the fasting state (P fasting states, Cmax was 32.0 ng/mL versus 57.3 ng/mL (P < .001), respectively, and Tmax was 3.0 h versus 0.92 h (P < .001), respectively. Together these data suggest that administration of ZST in the fed state is not optimal for maximizing the likelihood of therapeutic benefit and minimizing the probability of residual sedation. © 2013, The American College of Clinical Pharmacology.

  5. Energy and traffic light labelling have no impact on parent and child fast food selection.

    Science.gov (United States)

    Dodds, Pennie; Wolfenden, Luke; Chapman, Kathy; Wellard, Lyndal; Hughes, Clare; Wiggers, John

    2013-10-25

    Labelling of food from fast food restaurants at point-of-purchase has been suggested as one strategy to reduce population energy consumption and contribute to reductions in obesity prevalence. The aim of this study was to examine the effects of energy and single traffic light labelling systems on the energy content of child and adult intended food purchases. The study employed a randomised controlled trial design. English speaking parents of children aged between three and 12 years were recruited from an existing research cohort. Participants were mailed one of three hypothetical fast food menus. Menus differed in their labelling technique- either energy labels, single traffic light labels, or a no-label control. Participants then completed a telephone survey which assessed intended food purchases for both adult and child. The primary trial outcome was total energy of intended food purchase. A total of 329 participants completed the follow-up telephone interview. Eighty-two percent of the energy labelling group and 96% of the single traffic light labelling group reported noticing labelling information on their menu. There were no significant differences in total energy of intended purchases of parents, or intended purchases made by parents for children, between the menu labelling groups, or between menu labelling groups by socio-demographic subgroups. This study provided no evidence to suggest that energy labelling or single traffic light labelling alone were effective in reducing the energy of fast food items selected from hypothetical fast food menus for purchase. Additional complementary public health initiatives promoting the consumption of healthier foods identified by labelling, and which target other key drivers of menu item selection in this setting may be required. Copyright © 2013. Published by Elsevier Ltd.

  6. FastChem: An ultra-fast equilibrium chemistry

    Science.gov (United States)

    Kitzmann, Daniel; Stock, Joachim

    2018-04-01

    FastChem is an equilibrium chemistry code that calculates the chemical composition of the gas phase for given temperatures and pressures. Written in C++, it is based on a semi-analytic approach, and is optimized for extremely fast and accurate calculations.

  7. System cost - a criterion for the economic comparison of fast reactors

    International Nuclear Information System (INIS)

    Iliffe, C.E.

    1978-01-01

    The concept of electricity cost for a single station is derived from general considerations of profitability, including the effect of inflation. This derivation leads to the further one of system cost which is especially relevant to fast reactors in that plutonium is automatically allowed for. (author)

  8. Verification and Validation of Multisegmented Mooring Capabilities in FAST v8

    DEFF Research Database (Denmark)

    Andersen, Morten Thøtt; Wendt, Fabian F.; Robertson, Amy N.

    2016-01-01

    The quasi-static and dynamic mooring modules of the open-source aero-hydro-servo-elastic wind turbine simulation software, FAST v8, have previously been verified and validated, but only for mooring arrangements consisting of single lines connecting each fairlead and anchor. This paper extends the...

  9. Neighborhood fast food restaurants and fast food consumption: A national study

    OpenAIRE

    Richardson, Andrea S; Boone-Heinonen, Janne; Popkin, Barry M; Gordon-Larsen, Penny

    2011-01-01

    Abstract Background Recent studies suggest that neighborhood fast food restaurant availability is related to greater obesity, yet few studies have investigated whether neighborhood fast food restaurant availability promotes fast food consumption. Our aim was to estimate the effect of neighborhood fast food availability on frequency of fast food consumption in a national sample of young adults, a population at high risk for obesity. Methods We used national data from U.S. young adults enrolled...

  10. Radiation hardness tests and characterization of the CLARO-CMOS, a low power and fast single-photon counting ASIC in 0.35 micron CMOS technology

    International Nuclear Information System (INIS)

    Fiorini, M.; Andreotti, M.; Baldini, W.; Calabrese, R.; Carniti, P.; Cassina, L.; Cotta Ramusino, A.; Giachero, A.; Gotti, C.; Luppi, E.; Maino, M.; Malaguti, R.; Pessina, G.; Tomassetti, L.

    2014-01-01

    The CLARO-CMOS is a prototype ASIC that allows fast photon counting with 5 ns peaking time, a recovery time to baseline smaller than 25 ns, and a power consumption of less than 1 mW per channel. This chip is capable of single-photon counting with multi-anode photomultipliers and finds applications also in the read-out of silicon photomultipliers and microchannel plates. The prototype is realized in AMS 0.35 micron CMOS technology. In the LHCb RICH environment, assuming 10 years of operation at the nominal luminosity expected after the upgrade in Long Shutdown 2 (LS2), the ASIC must withstand a total fluence of about 6×10 12 1 MeV n eq /cm 2 and a total ionizing dose of 400 krad. A systematic evaluation of the radiation effects on the CLARO-CMOS performance is therefore crucial to ensure long term stability of the electronics front-end. The results of multi-step irradiation tests with neutrons and X-rays up to the fluence of 10 14 cm −2 and a dose of 4 Mrad, respectively, are presented, including measurement of single event effects during irradiation and chip performance evaluation before and after each irradiation step. - Highlights: • CLARO chip capable of single-photon counting with 5 ns peaking time. • Chip irradiated up to very high neutron, proton and X-rays fluences, as expected for upgraded LHCb RICH detectors. • No significant performance degradation is observed after irradiation

  11. Electron-impact ionization of SiCl{sub 3} using an improved crossed fast-neutral-beam - electron-beam apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, J M; Gutkin, M V; Tarnovsky, V; Becker, K [Department of Physics and Engineering Physics, Stevens Institute of Technology, Hoboken, NJ 07030 (United States)], E-mail: kbecker@poly.edu

    2008-05-15

    The fast-neutral-beam technique is a versatile approach to the determination of absolute cross sections for electron-impact ionization of atoms, stable molecules as well as free radicals and metastable species. A fast neutral beam of the species under study is prepared by charge-transfer neutralization of a mass-selected ion beam and the species are subsequently ionized by an electron beam. Mass- and energy-dispersive selection separates singly from multiply charged ions and parent from fragment ions and allows the determination of partial ionization cross sections. Here we describe some major improvements that were made recently to the fast-beam apparatus that has been used extensively for ionization cross section measurements for the past 15 years in our group. Experiments using well-established ionization cross sections in conjunction with extensive ion trajectory simulations were carried out to test the satisfactory performance of the modified fast-neutral-beam apparatus. We also report absolute partial cross sections for the formation of various singly charged positive ions produced by electron impact on SiCl{sub 3} for impact energies from threshold to 200 eV in the modified fast-beam apparatus.

  12. Comparison of Fast-Food and Non-Fast-Food Children's Menu Items

    Science.gov (United States)

    Serrano, Elena L.; Jedda, Virginia B.

    2009-01-01

    Objective: Compare the macronutrient content of children's meals sold by fast-food restaurants (FFR) and non-fast-food restaurants (NFF). Design: All restaurants within the designated city limits were surveyed. Non-fast-food children's meals were purchased, weighed, and analyzed using nutrition software. All fast-food children's meals were…

  13. Stilbene crystalline powder in polymer base as a new fast neutron detector

    International Nuclear Information System (INIS)

    Budakovsky, S.V.; Galunov, N.Z.; Grinyov, B.V.; Karavaeva, N.L.; Kyung Kim, Jong; Kim, Yong-Kyun; Pogorelova, N.V.; Tarasenko, O.A.

    2007-01-01

    A new organic scintillation material consisting of stilbene grains in a polymer glue base is presented. The crystalline grains of stilbene are obtained by mechanical grinding of stilbene single crystals. The resulting composite scintillators have been studied as detectors for fast neutrons

  14. Single-incision laparoscopic distal gastrectomy for early gastric cancer through a homemade single port access device.

    Science.gov (United States)

    Jiang, Zhi-Wei; Zhang, Shu; Wang, Gang; Zhao, Kun; Liu, Jiang; Ning, Li; Li, Jieshou

    2015-01-01

    We presented a series of single-incision laparoscopic distal gastrectomies for early gastric cancer patients through a type of homemade single port access device and some other conventional laparoscopic instruments. A single-incision laparoscopic distal gastrectomy with D1 + α lymph node dissection was performed on a 46 years old male patient who had an early gastric cancer. This single port access device has facilitated the conventional laparoscopic instruments to accomplish the surgery and we made in only 6 minutes. Total operating time for this surgery was 240 minutes. During the operation, there were about 100 milliliters of blood loss, and 17 lymph-nodes were retrieved. This homemade single port access device shows its superiority in economy and convenience for complex single-incision surgeries. Single-incision laparoscopic distal gastrectomy for early gastric cancer can be conducted by experienced laparoscopic surgeons. Fully take advantage of both SILS and fast track surgery plan can bring to successful surgeries with minimal postoperative pain, quicker mobilization, early recovery of intestinal function, and better cosmesis effect for the patients.

  15. Diagnosis of bile acid diarrhoea by fasting and postprandial measurements of fibroblast growth factor 19

    DEFF Research Database (Denmark)

    Borup, Christian; Syversen, Charlotte; Bouchelouche, Pierre

    2015-01-01

    BACKGROUND: A deficiency in the ileal hormone fibroblast growth factor 19 (FGF19) has been described in patients with bile acid diarrhoea (BAD), but fasting FGF19 levels have insufficient diagnostic power. We assess whether single postprandial sampling of FGF19 has greater discriminative value than...... fasting FGF19 for detection of BAD and we evaluate the reproducibility of fasting FGF19. MATERIALS AND METHODS: Twenty-six patients consecutively referred to Se homocholic acid retention test (SeHCAT) were included. Serum FGF19 was measured after an overnight fast and again 1 h postprandially and again...... in the fasting state 1 week later. RESULTS: Nine of 26 patients had SeHCAT less than 10% and fasting FGF19 was lower [median 62 pg/ml, interquartile range (IQR): 47-67] than in the 17 diarrhoea controls with SeHCAT at least 10% (median 103 pg/ml, IQR: 77-135, P=0.006). Postprandial FGF19 in BAD patients (61 pg...

  16. Influence of crosstalk on the fast fluid attenuated inversion recovery pulse sequence

    International Nuclear Information System (INIS)

    Urata, Tohru; Nonoshita, Koji; Miyazaki, Takayuki; Arima, Akira

    2000-01-01

    The influence of crosstalk on the fast fluid attenuated inversion recovery (fast FLAIR) pulse sequence was studied. On multislice fast FLAIR images, the water null point was shortened in comparison with that on single slice images owing to the crosstalk received from adjacent slices. That influence became greater with decreases in the slice gap and increases in the number of slices. The timing of crosstalk in each slice varied according to excitation order. The process of recovery of longitudinal magnetization changed according to differences in timing; thus, it was possible that the water null point changed in each slice. In brain images with thinner slice gaps, the signal intensity of CSF is increased by the effect of crosstalk. In order to eliminate changes in the water null point caused by crosstalk on fast FLAIR, the multislice sequence requires a sequence with interleaving based on the premise that slice gaps are set for more than 100% of slice thickness. (author)

  17. Influence of crosstalk on the fast fluid attenuated inversion recovery pulse sequence

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Tohru; Nonoshita, Koji; Miyazaki, Takayuki; Arima, Akira [Funabashi Municipal Medical Center, Chiba (Japan)

    2000-04-01

    The influence of crosstalk on the fast fluid attenuated inversion recovery (fast FLAIR) pulse sequence was studied. On multislice fast FLAIR images, the water null point was shortened in comparison with that on single slice images owing to the crosstalk received from adjacent slices. That influence became greater with decreases in the slice gap and increases in the number of slices. The timing of crosstalk in each slice varied according to excitation order. The process of recovery of longitudinal magnetization changed according to differences in timing; thus, it was possible that the water null point changed in each slice. In brain images with thinner slice gaps, the signal intensity of CSF is increased by the effect of crosstalk. In order to eliminate changes in the water null point caused by crosstalk on fast FLAIR, the multislice sequence requires a sequence with interleaving based on the premise that slice gaps are set for more than 100% of slice thickness. (author)

  18. Test model of the fast thyristor circuit breaker, for TORE SUPRA

    International Nuclear Information System (INIS)

    Bareyt, B.; Leloup, C.; Rijnoudt, E.

    1984-01-01

    The tokamak TORE SUPRA, permits, owing to the toroidal superconducting coils and to the poloidal field system performances, long discharges (30 s and more), for a plasma current of typically 2 MA. The poloidal field system uses the magnetic energy initially stored, for the ignition and the fast rise of the plasma current, by forcing the primary current to flow through a resistor after breaking the main rectifier current by a fast thyristor circuit breaker. In order to test the technical capabilities of such a breaker system made of fast thyristors, in series and in parallel, after a single thyristor test model T1 the series arrangement was studied on a 24 thyristor test model T2 and the parallel arrangement problems, led the manufacturer CGEE Alsthom, to build a new test model T3. (author)

  19. Multirobot FastSLAM Algorithm Based on Landmark Consistency Correction

    Directory of Open Access Journals (Sweden)

    Shi-Ming Chen

    2014-01-01

    Full Text Available Considering the influence of uncertain map information on multirobot SLAM problem, a multirobot FastSLAM algorithm based on landmark consistency correction is proposed. Firstly, electromagnetism-like mechanism is introduced to the resampling procedure in single-robot FastSLAM, where we assume that each sampling particle is looked at as a charged electron and attraction-repulsion mechanism in electromagnetism field is used to simulate interactive force between the particles to improve the distribution of particles. Secondly, when multiple robots observe the same landmarks, every robot is regarded as one node and Kalman-Consensus Filter is proposed to update landmark information, which further improves the accuracy of localization and mapping. Finally, the simulation results show that the algorithm is suitable and effective.

  20. Software for fast cameras and image handling on MAST

    International Nuclear Information System (INIS)

    Shibaev, S.

    2008-01-01

    The rapid progress in fast imaging gives new opportunities for fusion research. The data obtained by fast cameras play an important and ever-increasing role in analysis and understanding of plasma phenomena. The fast cameras produce a huge amount of data which creates considerable problems for acquisition, analysis, and storage. We use a number of fast cameras on the Mega-Amp Spherical Tokamak (MAST). They cover several spectral ranges: broadband visible, infra-red and narrow band filtered for spectroscopic studies. These cameras are controlled by programs developed in-house. The programs provide full camera configuration and image acquisition in the MAST shot cycle. Despite the great variety of image sources, all images should be stored in a single format. This simplifies development of data handling tools and hence the data analysis. A universal file format has been developed for MAST images which supports storage in both raw and compressed forms, using either lossless or lossy compression. A number of access and conversion routines have been developed for all languages used on MAST. Two movie-style display tools have been developed-Windows native and Qt based for Linux. The camera control programs run as autonomous data acquisition units with full camera configuration set and stored locally. This allows easy porting of the code to other data acquisition systems. The software developed for MAST fast cameras has been adapted for several other tokamaks where it is in regular use

  1. Fast Fourier single-pixel imaging via binary illumination.

    Science.gov (United States)

    Zhang, Zibang; Wang, Xueying; Zheng, Guoan; Zhong, Jingang

    2017-09-20

    Fourier single-pixel imaging (FSI) employs Fourier basis patterns for encoding spatial information and is capable of reconstructing high-quality two-dimensional and three-dimensional images. Fourier-domain sparsity in natural scenes allows FSI to recover sharp images from undersampled data. The original FSI demonstration, however, requires grayscale Fourier basis patterns for illumination. This requirement imposes a limitation on the imaging speed as digital micro-mirror devices (DMDs) generate grayscale patterns at a low refreshing rate. In this paper, we report a new strategy to increase the speed of FSI by two orders of magnitude. In this strategy, we binarize the Fourier basis patterns based on upsampling and error diffusion dithering. We demonstrate a 20,000 Hz projection rate using a DMD and capture 256-by-256-pixel dynamic scenes at a speed of 10 frames per second. The reported technique substantially accelerates image acquisition speed of FSI. It may find broad imaging applications at wavebands that are not accessible using conventional two-dimensional image sensors.

  2. A Generic Simulation Approach for the Fast and Accurate Estimation of the Outage Probability of Single Hop and Multihop FSO Links Subject to Generalized Pointing Errors

    KAUST Repository

    Ben Issaid, Chaouki; Park, Kihong; Alouini, Mohamed-Slim

    2017-01-01

    When assessing the performance of the free space optical (FSO) communication systems, the outage probability encountered is generally very small, and thereby the use of nave Monte Carlo simulations becomes prohibitively expensive. To estimate these rare event probabilities, we propose in this work an importance sampling approach which is based on the exponential twisting technique to offer fast and accurate results. In fact, we consider a variety of turbulence regimes, and we investigate the outage probability of FSO communication systems, under a generalized pointing error model based on the Beckmann distribution, for both single and multihop scenarios. Selected numerical simulations are presented to show the accuracy and the efficiency of our approach compared to naive Monte Carlo.

  3. A Generic Simulation Approach for the Fast and Accurate Estimation of the Outage Probability of Single Hop and Multihop FSO Links Subject to Generalized Pointing Errors

    KAUST Repository

    Ben Issaid, Chaouki

    2017-07-28

    When assessing the performance of the free space optical (FSO) communication systems, the outage probability encountered is generally very small, and thereby the use of nave Monte Carlo simulations becomes prohibitively expensive. To estimate these rare event probabilities, we propose in this work an importance sampling approach which is based on the exponential twisting technique to offer fast and accurate results. In fact, we consider a variety of turbulence regimes, and we investigate the outage probability of FSO communication systems, under a generalized pointing error model based on the Beckmann distribution, for both single and multihop scenarios. Selected numerical simulations are presented to show the accuracy and the efficiency of our approach compared to naive Monte Carlo.

  4. Fast Food Jobs. National Study of Fast Food Employment.

    Science.gov (United States)

    Charner, Ivan; Fraser, Bryna Shore

    A study examined employment in the fast-food industry. The national survey collected data from employees at 279 fast-food restaurants from seven companies. Female employees outnumbered males by two to one. The ages of those fast-food employees in the survey sample ranged from 14 to 71, with fully 70 percent being in the 16- to 20-year-old age…

  5. Metal ion protection of DNA to fast neutron irradiation

    International Nuclear Information System (INIS)

    Constantinescu, B.; Bugoi, R.; Radulescu, I.; Radu, L.

    1998-01-01

    The most important effects of the ionising radiation are the single and double strand breaks (SSB and DBS), modifications of the DNA bases and deoxyribose, as well as the occurrence of alkali and heat labile sites (revealed as strand breaks after alkaline or thermic treatment of irradiated DNA). The ionising particles can have either direct effects on the DNA constituents or indirect effects, mediated by the OH - radicals, produced by water radiolysis. The occurrence of SSB and DSB in the chromatin DNA strands is supposed to hinder the DNA-dye complex formation. Usually, the dyes present different fluorescence parameters in the two possible states, so one can correlate the lifetime or the quantum yield with the extent of the damage. We took into account the protective effect offered both by histones, which behave as 'scavenger molecules' for OH - radicals and by the high compactness of DNA chromatin. Similar protective effects might be the results of the metallic ion addition which triggers some conformational transitions of the chromatin DNA towards a highly compacted structure. In this paper we present a study of the complexes of fast neutron irradiated chromatin with proflavine. Fluorimetric and time resolved spectroscopic determinations (single photon counting method) of chromatin-Pr complexes were realised. Information regarding the chromatin protein damage were obtained by monitoring the fluorescence of Trp. The chromatin was irradiated (20-100 Gy) with fast neutrons, obtained by the reaction of 13.5 MeV deuterons on a thick beryllium target at the IFIN-HH U-120 Cyclotron. The dose mean lineal energy in water at the point of interest was 50 keV/m and the mean dose rate was 1.5 Gy/min. By fluorescence determinations, changes of the Pr intercalation parameters in fast neutron irradiated chromatin DNA have been observed. Fluorescence techniques provide valuable information on the binding equilibrium by considering the radiation deexcitation of the complex. The

  6. Fast MR imaging and ultrafast MR imaging of fetal central nervous system abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Shakudo, Miyuki; Manabe, Takao; Murata, Katsuko; Matsuo, Ryoichi; Oda, Junro [Osaka City General Hospital (Japan); Inoue, Yuichi; Mochizuki, Kunizo; Yamada, Ryusaku

    2001-12-01

    The aims of this study were two: to compare the efficacy of fast MRI (breath-hold fast spin-echo T2-weighted and fast gradient-echo T1-weighted sequence) and ultrafast MRI (half-Fourier acquisition single-shot turbo spin-echo sequence) in evaluation of fetal central nervous system (CNS) abnormalities at late gestational age, and to compare the capability of fast MRI and ultrafast MRI to assess fetal CNS abnormalities with that of prenatal ultrasonography (US). Forty-nine women with fetuses at gestational ages of 26-39 weeks underwent fast MRI (29 patients) or ultrafast MRI (20 patients). In detection of motion artifact, visualization of the lateral and 4th ventricles, and differentiation between gray and white matter in cerebral hemispheres, ultrafast MRI was significantly superior to fast MRI (p<0.0001, Mann-Whitney U test). In 25 of 43 cases, US and MR diagnoses were the same and consistent with postnatal diagnosis. In 10 of 43 cases, MRI demonstrated findings additional to or different from those of US, and MR findings were confirmed postnatally. MRI, particularly ultrafast MRI, is useful for demonstrating CNS abnormalities in situations in which US is suggestive but not definitive. (author)

  7. Membranes for nanometer-scale mass fast transport

    Science.gov (United States)

    Bakajin, Olgica [San Leandro, CA; Holt, Jason [Berkeley, CA; Noy, Aleksandr [Belmont, CA; Park, Hyung Gyu [Oakland, CA

    2011-10-18

    Nanoporous membranes comprising single walled, double walled, and multiwalled carbon nanotubes embedded in a matrix material were fabricated for fluid mechanics and mass transfer studies on the nanometer scale and commercial applications. Average pore size can be 2 nm to 20 nm, or seven nm or less, or two nanometers or less. The membrane can be free of large voids spanning the membrane such that transport of material such as gas or liquid occurs exclusively through the tubes. Fast fluid, vapor, and liquid transport are observed. Versatile micromachining methods can be used for membrane fabrication. A single chip can comprise multiple membranes. These membranes are a robust platform for the study of confined molecular transport, with applications in liquid and gas separations and chemical sensing including desalination, dialysis, and fabric formation.

  8. Quantitative fuel motion determination with the CABRI fast neutron hodoscope

    International Nuclear Information System (INIS)

    Baumung, K.; Augier, G.

    1991-01-01

    The fast neutron hodoscope installed at the CABRI reactor in Cadarache, France, is employed to provide quantitative fuel motion data during experiments in which single liquid-metal fast breeder reactor test pins are subjected to simulated accident conditions. Instrument design and performance are reviewed, the methods for the quantitative evaluation are presented, and error sources are discussed. The most important findings are the axial expansion as a function of time, phenomena related to pin failure (such as time, location, pin failure mode, and fuel mass ejected after failure), and linear fuel mass distributions with a 2-cm axial resolution. In this paper the hodoscope results of the CABRI-1 program are summarized

  9. A fast ECL bus memory: dual input memory

    International Nuclear Information System (INIS)

    Cesaroni, F.; Pascale, G.; Gentile, S.; Gao, Z.

    1992-01-01

    A fast and flexible dual input memory (DIM) has been constructed as single CAMAC unit. The device has been designed to receive via front panel two 16-bit data words, which can be stored in sequential mode into a memory and, at the same time, presented on the output. The design implemented also the possibility to connect 16-bit differential ECL outputs of many DIMs modules on the same bus. Its timing characteristics for writing and reading into and from memory is only 20 ns. This makes the module a useful element for all kinds of fast acquisition systems, as tempory storage of data, or data source or spy module. It will be, for example, used in the new energy tripper of the L3 experiment, designed for 8x8 bunch mode operation of LEP in 1992. (orig.)

  10. Ultra fast shutter driven by pulsed high current

    International Nuclear Information System (INIS)

    Zeng Jiangtao; Sun Fengju; Qiu Aici; Yin Jiahui; Guo Jianming; Chen Yulan

    2005-01-01

    Radiation simulation utilizing plasma radiation sources (PRS) generates a large number of undesirable debris, which may damage the expensive diagnosing detectors. An ultra fast shutter (UFS) driven by pulsed high current can erect a physical barrier to the slowly moving debris after allowing the passage of X-ray photons. The UFS consists of a pair of thin metal foils twisting the parallel axes in a Nylon cassette, compressed with an outer magnetic field, generated from a fast capacitor bank, discharging into a single turn loop. A typical capacitor bank is of 7.5 μF charging voltages varying from 30 kV to 45 kV, with corresponding currents of approximately 90 kA to 140 kA and discharging current periods of approximately 13.1 μs. A shutter closing time as fast as 38 microseconds has been obtained with an aluminium foil thickness of 100 micrometers and a cross-sectional area of 15 mm by 20 mm. The design, construction and the expressions of the valve-closing time of the UFS are presented along with the measured results of valve-closing velocities. (authors)

  11. nGEM fast neutron detectors for beam diagnostics

    International Nuclear Information System (INIS)

    Croci, G.; Claps, G.; Cavenago, M.; Dalla Palma, M.; Grosso, G.; Murtas, F.; Pasqualotto, R.; Perelli Cippo, E.; Pietropaolo, A.; Rebai, M.; Tardocchi, M.; Tollin, M.; Gorini, G.

    2013-01-01

    Fast neutron detectors with a sub-millimetric space resolution are required in order to qualify neutron beams in applications related to magnetically-controlled nuclear fusion plasmas and to spallation sources. A nGEM detector has been developed for the CNESM diagnostic system of the SPIDER NBI prototype for ITER and as beam monitor for fast neutrons lines at spallation sources. The nGEM is a triple GEM gaseous detector equipped with polypropylene and polyethylene layers used to convert fast neutrons into recoil protons through the elastic scattering process. This paper describes the results obtained by testing a nGEM detector at the ISIS spallation source on the VESUVIO beam line. Beam profiles (σ x =14.35 mm, σ y =15.75 mm), nGEM counting efficiency (around 10 -4 for 3 MeV n <15 MeV), detector stability (≈4.5%) and the effect of filtering the beam with different type of materials were successfully measured. The x beam profile was compared to the one measured by a single crystal diamond detector. Finally, the efficiency of the detector was simulated exploiting the GEANT4 tool

  12. Single-fiber myosin heavy chain polymorphism during postnatal development: modulation by hypothyroidism

    Science.gov (United States)

    di Maso, N. A.; Caiozzo, V. J.; Baldwin, K. M.

    2000-01-01

    The primary objective of this study was to follow the developmental time course of myosin heavy chain (MHC) isoform transitions in single fibers of the rodent plantaris muscle. Hypothyroidism was used in conjunction with single-fiber analyses to better describe a possible linkage between the neonatal and fast type IIB MHC isoforms during development. In contrast to the general concept that developmental MHC isoform transitions give rise to muscle fibers that express only a single MHC isoform, the single-fiber analyses revealed a very high degree of MHC polymorphism throughout postnatal development. In the adult state, MHC polymorphism was so pervasive that the rodent plantaris muscles contained approximately 12-15 different pools of fibers (i.e., fiber types). The degree of polymorphism observed at the single-fiber level made it difficult to determine specific developmental schemes analogous to those observed previously for the rodent soleus muscle. However, hypothyroidism was useful in that it confirmed a possible link between the developmental regulation of the neonatal and fast type IIB MHC isoforms.

  13. Fast neutron spectrometer with pulse shape discrimination

    International Nuclear Information System (INIS)

    Verbitsky, S.S.

    1978-01-01

    A fast neutron spectrometer with a stilbene single crystal designed to operate at high pulsed count rate has been described. Making use of identification and rejection of events, accompanied by pile-up, allowed to increase permissible count rates by an order of magnitude. The results of energy dependence of signal amplitude and shape relative anisotropy in stilbene in the range 4-10 and 2-8 MeV respectively have been presented. Taking into account anisotropy of the detector-scintillation properties allowed to improve particle discrimination. (Auth.)

  14. Fast RF-CV characterization through high-speed 1-port S-parameter measurements

    NARCIS (Netherlands)

    Herfst, R.W.; Steeneken, P.G.; Tiggelman, M.P.J.; Stulemeijer, J.; Schmitz, Jurriaan

    2010-01-01

    We present a novel method to measure the capacitance-voltage relation of an electronic device. The approach is accurate, very fast, and cost-effective compared to the existing off-the-shelf solutions. Capacitances are determined using a single-frequency 1-port S-parameter setup constructed from

  15. Efficacy and speed of onset of pain relief of fast-dissolving paracetamol on postsurgical dental pain: two randomized, single-dose, double-blind, placebo-controlled clinical studies.

    Science.gov (United States)

    Yue, Yong; Collaku, Agron; Brown, Jean; Buchanan, William L; Reed, Kenneth; Cooper, Stephen A; Otto, James

    2013-09-01

    Paracetamol (APAP), also known as acetaminophen, is the most commonly used over-the-counter analgesic for the treatment of mild-to-moderate pain. However, the speed of onset of pain relief is limited mainly to the standard, immediate-release formulation. Efficacy and speed of onset of pain relief are critical in acute pain situations such as postsurgical dental pain, because reducing pain can improve clinical outcome and reduce the risk of transition from acute pain to more chronic pain. Efficacy and rapid onset also reduce the risk of excessive dosing with the analgesic. We sought to investigate the dose-response efficacy and speed of onset of pain relief of a fast-dissolving APAP formulation compared with lower doses of APAP and placebo in dental patients after impacted third molar extraction. Two single-center, single-dose, randomized, placebo-controlled, double-blind, double-dummy, parallel-group studies (Study I and Study II) were conducted to evaluate the efficacy and speed of onset of pain relief of different doses of a fast-dissolving APAP tablet (FD-APAP), standard APAP, and placebo in patients with postsurgical dental pain following third molar extraction. In Study I, a single dose of FD-APAP 1000 mg, FD-APAP 500 mg, or placebo was given to 300 patients; in Study II, a single dose of FD-APAP 1000 mg, standard APAP 650 mg, or placebo was given to 401 patients. All 701 patients from both studies were included in the analysis and safety assessment. FD-APAP 1000 mg demonstrated significantly greater effect compared with FD-APAP 500 mg, APAP 650 mg, and placebo for all efficacy measurements, including sum of pain relief and pain intensity difference, total pain relief, sum of pain intensity difference, pain intensity difference, and pain relief score during 6 hours after the dose. Onset of confirmed first perceptible relief in subjects treated with FD-APAP 1000 mg was 15 minutes, which was 32% and 25% significantly shorter than onset of pain relief of FD

  16. Longitudinal stability of MRI for mapping brain change using tensor-based morphometry

    Science.gov (United States)

    Leow, Alex D.; Klunder, Andrea D.; Jack, Clifford R.; Toga, Arthur W.; Dale, Anders M.; Bernstein, Matt A.; Britson, Paula J.; Gunter, Jeffrey L.; Ward, Chadwick P.; Whitwell, Jennifer L.; Borowski, Bret J.; Fleisher, Adam S.; Fox, Nick C.; Harvey, Danielle; Kornak, John; Schuff, Norbert; Studholme, Colin; Alexander, Gene E.; Weiner, Michael W.; Thompson, Paul M.

    2007-01-01

    Measures of brain change can be computed from sequential MRI scans, providing valuable information on disease progression, e.g., for patient monitoring and drug trials. Tensor-based morphometry (TBM) creates maps of these brain changes, visualizing the 3D profile and rates of tissue growth or atrophy, but its sensitivity depends on the contrast and geometric stability of the images. A s part of the Alzheimer’s Disease Neuroimaging Initiative (ADNI), 17 normal elderly subjects were scanned twice (at a 2-week interval) with several 3D 1.5 T MRI pulse sequences: high and low flip angle SPGR/FLASH (from which Synthetic T1 images were generated), MP-RAGE, IR-SPGR (N = 10) and MEDIC (N = 7) scans. For each subject and scan type, a 3D deformation map aligned baseline and follow-up scans, computed with a nonlinear, inverse-consistent elastic registration algorithm. Voxelwise statistics, in ICBM stereotaxic space, visualized the profile of mean absolute change and its cross-subject variance; these maps were then compared using permutation testing. Image stability depended on: (1) the pulse sequence; (2) the transmit/receive coil type (birdcage versus phased array); (3) spatial distortion corrections (using MEDIC sequence information); (4) B1-field intensity inhomogeneity correction (using N3). SPGR/FLASH images acquired using a birdcage coil had least overall deviation. N3 correction reduced coil type and pulse sequence differences and improved scan reproducibility, except for Synthetic T1 images (which were intrinsically corrected for B1-inhomogeneity). No strong evidence favored B0 correction. Although SPGR/FLASH images showed least deviation here, pulse sequence selection for the ADNI project was based on multiple additional image analyses, to be reported elsewhere. PMID:16480900

  17. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences

    Energy Technology Data Exchange (ETDEWEB)

    Ruangwattanapaisarn, Nichanan [Mahidol University, Department of Diagnostic and Therapeutic Radiology, Ramathibodi Hospital, Bangkok (Thailand); Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Loening, Andreas M.; Saranathan, Manojkumar; Vasanawala, Shreyas S. [Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Litwiller, Daniel V. [GE Healthcare, Rochester, MN (United States)

    2015-06-15

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity. (orig.)

  18. Spectroscopic characterization of Venus at the single molecule level.

    Science.gov (United States)

    David, Charlotte C; Dedecker, Peter; De Cremer, Gert; Verstraeten, Natalie; Kint, Cyrielle; Michiels, Jan; Hofkens, Johan

    2012-02-01

    Venus is a recently developed, fast maturating, yellow fluorescent protein that has been used as a probe for in vivo applications. In the present work the photophysical characteristics of Venus were analyzed spectroscopically at the bulk and single molecule level. Through time-resolved single molecule measurements we found that single molecules of Venus display pronounced fluctuations in fluorescence emission, with clear fluorescence on- and off-times. These fluorescence intermittencies were found to occupy a broad range of time scales, ranging from milliseconds to several seconds. Such long off-times can complicate the analysis of single molecule counting experiments or single-molecule FRET experiments. This journal is © The Royal Society of Chemistry and Owner Societies 2012

  19. The fast reactor

    International Nuclear Information System (INIS)

    1980-02-01

    The subject is discussed as follows: brief description of fast reactors; advantage in conserving uranium resources; experience, in UK and elsewhere, in fast reactor design, construction and operation; safety; production of plutonium, security aspects; consideration of future UK fast reactor programme. (U.K.)

  20. Risk of falls in older people during fast-walking--the TASCOG study.

    Science.gov (United States)

    Callisaya, M L; Blizzard, L; McGinley, J L; Srikanth, V K

    2012-07-01

    To investigate the relationship between fast-walking and falls in older people. Individuals aged 60-86 years were randomly selected from the electoral roll (n=176). Gait speed, step length, cadence and a walk ratio were recorded during preferred- and fast-walking using an instrumented walkway. Falls were recorded prospectively over 12 months. Log multinomial regression was used to estimate the relative risk of single and multiple falls associated with gait variables during fast-walking and change between preferred- and fast-walking. Covariates included age, sex, mood, physical activity, sensorimotor and cognitive measures. The risk of multiple falls was increased for those with a smaller walk ratio (shorter steps, faster cadence) during fast-walking (RR 0.92, CI 0.87, 0.97) and greater reduction in the walk ratio (smaller increase in step length, larger increase in cadence) when changing to fast-walking (RR 0.73, CI 0.63, 0.85). These gait patterns were associated with poorer physiological and cognitive function (prisk of multiple falls was also seen for those in the fastest quarter of gait speed (p=0.01) at fast-walking. A trend for better reaction time, balance, memory and physical activity for higher categories of gait speed was stronger for fallers than non-fallers (prisk of multiple falls. There may be two distinct groups at risk--the frail person with short shuffling steps, and the healthy person exposed to greater risk. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Simultaneous acquisition of three NMR spectra in a single ...

    Indian Academy of Sciences (India)

    Simultaneous acquisition of three NMR spectra in a single experiment ... set, which is based on a combination of different fast data acquisition techniques such as G-matrix ..... The sign and intensity of the CHn resonance depends on the delay.

  2. Inorganic component of saliva during fasting and after fast break

    OpenAIRE

    Samad, Rasmidar

    2016-01-01

    Oral health is closely related to salivary components. Saliva consists of water, inorganic and organic materials. Fasting changes one???s meal and drinking time that in turn can affect the environment in oral cavity, including inorganic componenet of saliva. The purpose of this study is to determine the inorganic component of saliva during fasting and after fast break.

  3. Proximity to Fast-Food Outlets and Supermarkets as Predictors of Fast-Food Dining Frequency.

    Science.gov (United States)

    Athens, Jessica K; Duncan, Dustin T; Elbel, Brian

    2016-08-01

    This study used cross-sectional data to test the independent relationship of proximity to chain fast-food outlets and proximity to full-service supermarkets on the frequency of mealtime dining at fast-food outlets in two major urban areas, using three approaches to define access. Interactions between presence of a supermarket and presence of fast-food outlets as predictors of fast-food dining were also tested. Residential intersections for respondents in point-of-purchase and random-digit-dial telephone surveys of adults in Philadelphia, PA, and Baltimore, MD, were geocoded. The count of fast-food outlets and supermarkets within quarter-mile, half-mile, and 1-mile street network buffers around each respondent's intersection was calculated, as well as distance to the nearest fast-food outlet and supermarket. These variables were regressed on weekly fast-food dining frequency to determine whether proximity to fast food and supermarkets had independent and joint effects on fast-food dining. The effect of access to supermarkets and chain fast-food outlets varied by study population. Among telephone survey respondents, supermarket access was the only significant predictor of fast-food dining frequency. Point-of-purchase respondents were generally unaffected by proximity to either supermarkets or fast-food outlets. However, ≥1 fast-food outlet within a 1-mile buffer was an independent predictor of consuming more fast-food meals among point-of-purchase respondents. At the quarter-mile distance, ≥1 supermarket was predictive of fewer fast-food meals. Supermarket access was associated with less fast-food dining among telephone respondents, whereas access to fast-food outlets were associated with more fast-food visits among survey respondents identified at point-of-purchase. This study adds to the existing literature on geographic determinants of fast-food dining behavior among urban adults in the general population and those who regularly consume fast food. Copyright

  4. Measurements of fast neutron spectra in iron, uranium and sodium-iron assemblies

    International Nuclear Information System (INIS)

    Kappler, F.; Pieroni, N.; Rusch, D.; Schmidt, A.; Wattecamps, E.; Werle, H.

    1979-01-01

    Spectrum measurements were performed at the fast subcritical facility SUAK to test nuclear data and computer codes used in fast reactor calculations. In order to obtain a specific and quantitative interpretation of discrepancies between measured and calculated spectrum, homogeneous assemblies consisting of single materials were investigated. The leakage spectrum of iron and uranium cylinders was measured by time-of-flight and proportional counters. Time-dependent leakage spectra were measured by a NE 213 liquid scintillator. It was demonstrated that the investigation of time-dependent spectra is a sensitive test of inelastic scattering cross section data. The effect of an interface on fast neutron spectra was also investigated by measuring space dependent spectra across a sodium-iron interface. The measured spectra of these assemblies are suitable for testing the adequacy of computational approximations and cross section data. (author)

  5. Fast diffusion and nucleation of the amorphous phase in Ni--Zr films

    International Nuclear Information System (INIS)

    Ehrhart, P.; Averback, R.S.; Hahn, H.; Yadavalli, S.; Flynn, C.P.

    1988-01-01

    The nucleation of the amorphous phase by solid-state reactions has been investigated on single-crystal Zr films grown by molecular beam epitaxy and covered in situ with either polycrystalline Ni, amorphous (a-) NiZr, or single-crystalline Zr 99 N 01 films. Interfacial reactions were investigated by backscattering analysis or secondary ion mass spectroscopy. The amorphizing reaction occurred only in the specimen with the a-NiZr overlayer, although fast Ni diffusion through the single-crystalline Zr layer was observed in all three specimens. The nucleation behavior of a-NiZr is attributed to the combination of high-Ni and low-Zr mobility in crystalline Zr

  6. Fast ion behavior during neutral beam injection in ATF

    International Nuclear Information System (INIS)

    Wade, M.R.; Thomas, C.E.; Colchin, R.J.; Rome, J.A.; England, A.C.; Fowler, R.H.; Aceto, S.C.

    1993-01-01

    In stellarators, single-particle confinement properties can be more complex than in their tokamak counterparts. Fast-ion behavior in tokamaks has been well characterized through an abundance of measurements on various devices and in general has been shown to be consistent with classical slowing-down theory, although anomalous ion behavior has been observed during intense beam injection in ISX-B, during fishbone instabilities in PDX, and in experiments on TFR. In contrast, fast ion behavior in stellarators is not as wel established experimentally with the primary experiments to date focusing o near-perpendicular or perpendicular neutral beam injection (NBI) on the Wendelstein 7-A stellarator (91 and Heliotron-E. This paper addresses fast-ion confinement properties in a large-aspect-ratio, moderate-shear stellarator, the Advanced Toroidal Facility, during tangential NBI. The primary data used in this study are the experimentally measured energy spectra of charge-exchange neutrals escaping from the plasma, using a two-dimensional scanning neutral particle analyzer. This diagnostic method is well established, having been used on several devices since the early 1970's. Various aspects of fast-ion behavior are investigated by comparing these data with computed theoretical spectra based on energeticion distributions derived from the fastion Fokker-Planck equation. Ion orbits are studied by computer orbit following, by the computation of J* surfaces, and by Monte Carlo calculations

  7. Fast-ion Dα measurements of the fast-ion distribution (invited)

    International Nuclear Information System (INIS)

    Heidbrink, W. W.

    2010-01-01

    The fast-ion Dα (FIDA) diagnostic is an application of charge-exchange recombination spectroscopy. Fast ions that neutralize in an injected neutral beam emit Balmer-α light with a large Doppler shift. The spectral shift is exploited to distinguish the FIDA emission from other bright sources of Dα light. Background subtraction is the main technical challenge. A spectroscopic diagnostic typically achieves temporal, energy, and transverse spatial resolution of ∼1 ms, ∼10 keV, and ∼2 cm, respectively. Installations that use narrow-band filters achieve high spatial and temporal resolution at the expense of spectral information. For high temporal resolution, the bandpass-filtered light goes directly to a photomultiplier, allowing detection of ∼50 kHz oscillations in FIDA signal. For two-dimensional spatial profiles, the bandpass-filtered light goes to a charge-coupled device camera; detailed images of fast-ion redistribution at instabilities are obtained. Qualitative and quantitative models relate the measured FIDA signals to the fast-ion distribution function. The first quantitative comparisons between theory and experiment found excellent agreement in beam-heated magnetohydrodynamics (MHD)-quiescent plasmas. FIDA diagnostics are now in operation at magnetic-fusion facilities worldwide. They are used to study fast-ion acceleration by ion cyclotron heating, to detect fast-ion transport by MHD modes and microturbulence, and to study fast-ion driven instabilities.

  8. Electron correlation in single-electron capture from helium by fast protons

    International Nuclear Information System (INIS)

    Purkait, M

    2012-01-01

    The differential and total cross sections for single charge exchange in p-He collisions have been calculated within the framework of four-body boundary corrected continuum intermediate state (BCCIS-4B) approximation. The effect of dynamic electron correlations is explicitly taken into account through the complete perturbation potentials.

  9. Numerical study of the electron heating and current drive by the fast waves in the JFT-2M tokamak plasma

    International Nuclear Information System (INIS)

    Yamamoto, Takumi; Uesugi, Yoshihiko; Hoshino, Katsumichi; Kawashima, Hisato; Ohtsuka, Hideo

    1986-08-01

    A 200 MHz fast wave experiment for the JET-2M tokamak is examined. Noticeable single-path electron Landau damping of the fast waves with the parallel refractive index of N // = 4 is expected in the plasma with electron temperature more than 2.5 keV at the electron density of n e = 1.5 x 10 19 m -3 . Furthermore, it is shown that 8 kA of the plasma current is driven by the fast waves with N //≅ 2 at n e = 3 x 10 19 m -3 in the single-path damping when 100 kW of the rf power radiates into the plasma in the presence of the hot electrons with the temperature of 19 keV and the fraction of the density of 2 %. (author)

  10. Fasts, feasts and festivals in diabetes-1: Glycemic management during Hindu fasts

    Directory of Open Access Journals (Sweden)

    Sanjay Kalra

    2015-01-01

    Full Text Available This communication is the first of a series on South Asian fasts, festivals, and diabetes, designed to spread awareness and stimulate research on this aspect of diabetes and metabolic care. It describes the various fasts observed as part of Hindu religion and offers a classification scheme for them, labeling them as infrequent and frequent. The infrequent fasts are further sub-classified as brief and prolonged, to facilitate a scientific approach to glycemic management during these fasts. Pre-fast counseling, non-pharmacological therapy, pharmacological modification, and post-fast debriefing are discussed in detail. All available drug classes and molecules are covered in this article, which provides guidance about necessary changes in dosage and timing of administration. While in no way exhaustive, the brief review offers a basic framework which diabetes care professionals can use to counsel and manage persons in their care who wish to observe various Hindu fasts.

  11. A fast and versatile quantum key distribution system with hardware key distillation and wavelength multiplexing

    International Nuclear Information System (INIS)

    Walenta, N; Gisin, N; Guinnard, O; Houlmann, R; Korzh, B; Lim, C W; Lunghi, T; Portmann, C; Thew, R T; Burg, A; Constantin, J; Caselunghe, D; Kulesza, N; Legré, M; Monat, L; Soucarros, M; Trinkler, P; Junod, P; Trolliet, G; Vannel, F

    2014-01-01

    We present a compactly integrated, 625 MHz clocked coherent one-way quantum key distribution system which continuously distributes secret keys over an optical fibre link. To support high secret key rates, we implemented a fast hardware key distillation engine which allows for key distillation rates up to 4 Mbps in real time. The system employs wavelength multiplexing in order to run over only a single optical fibre. Using fast gated InGaAs single photon detectors, we reliably distribute secret keys with a rate above 21 kbps over 25 km of optical fibre. We optimized the system considering a security analysis that respects finite-key-size effects, authentication costs and system errors for a security parameter of ε QKD  = 4 × 10 −9 . (paper)

  12. Preoperative fasting times: Prescribed and actual fasting times at ...

    African Journals Online (AJOL)

    The current international guidelines for preoperative fasting for elective surgery are 6 ... to determine whether this policy was being followed and patients were being starved ..... recommended fasting time, so that autonomous patients take care.

  13. The influence of the polarization and power of a photon target on the near-threshold detachment of fast H- ions

    International Nuclear Information System (INIS)

    Artemov, A.S.; Avidzba, A.A.; Vartazaryan, A.S.

    1996-01-01

    The results of theoretical investigation of the single- and two-photon detachment of fast negative hydrogen ions obtained in the framework of the zero-range-potential approximation at a photon energy above the single-photon threshold, are presented. The corresponding cross sections and near-threshold partial distributions of photoelectrons in the space of transverse momenta and energy of the laboratory frame are investigated in detail for various light-field polarization and the cross angles of ion and photon fluxes. For purposes of beam diagnostics the possibility of effective control of the fast H - ion photodetachment in a probing laser target is shown. Taking into account single-photon and background two-photon detachment channels the expressions, that allow one to obtain the resulting distributions of photoelectrons for various light power and photon energy in the near-threshold area of interest, are presented. Choosing the target power, the space orientation of the momentum and polarization of photons, one can realize the conditions of transfer of needed information about the beam to fast electrons of hydrogen atoms with a maximum accuracy. (author). 44 refs., 19 figs

  14. Is carbohydrate mouth rinsing a novel approach to maintain exercise performance during Ramadan fasting?

    Directory of Open Access Journals (Sweden)

    Ahmad Munir Che Muhamed

    2014-12-01

    Full Text Available About a decade ago, carbohydrate mouth rinsing was shown to enhance endurance exercise performance. This improvement was more pronounced in a fasted compared to a fed state, suggesting that the ergogenic effect of carbohydrate mouth rinse is dependent on endogenous carbohydrate storage. Hence, indirectly highlights the potential use of carbohydrate mouth rinse as a potential strategy to mitigate the adverse effects of exercise during Ramadan fasting. To date, only one study has been carried out to explore the potential benefit of carbohydrate mouth rinse on exercise performance during Ramadan fasting. This single observation showed that a 10-km time trial performance was enhanced when performing mouth rinsing with either a carbohydrate or a placebo solution as compared with not performing mouth rinsing. While one study had acknowledged that the practice of mouth rinsing do have a positive effect on exercise performance during Ramadan fasting, future studies is warranted in order to have a better understanding on the underlying mechanisms associated with carbohydrate mouth rinsing during Ramadan fasting.

  15. Evaluating Fast Maximum Likelihood-Based Phylogenetic Programs Using Empirical Phylogenomic Data Sets

    Science.gov (United States)

    Zhou, Xiaofan; Shen, Xing-Xing; Hittinger, Chris Todd

    2018-01-01

    Abstract The sizes of the data matrices assembled to resolve branches of the tree of life have increased dramatically, motivating the development of programs for fast, yet accurate, inference. For example, several different fast programs have been developed in the very popular maximum likelihood framework, including RAxML/ExaML, PhyML, IQ-TREE, and FastTree. Although these programs are widely used, a systematic evaluation and comparison of their performance using empirical genome-scale data matrices has so far been lacking. To address this question, we evaluated these four programs on 19 empirical phylogenomic data sets with hundreds to thousands of genes and up to 200 taxa with respect to likelihood maximization, tree topology, and computational speed. For single-gene tree inference, we found that the more exhaustive and slower strategies (ten searches per alignment) outperformed faster strategies (one tree search per alignment) using RAxML, PhyML, or IQ-TREE. Interestingly, single-gene trees inferred by the three programs yielded comparable coalescent-based species tree estimations. For concatenation-based species tree inference, IQ-TREE consistently achieved the best-observed likelihoods for all data sets, and RAxML/ExaML was a close second. In contrast, PhyML often failed to complete concatenation-based analyses, whereas FastTree was the fastest but generated lower likelihood values and more dissimilar tree topologies in both types of analyses. Finally, data matrix properties, such as the number of taxa and the strength of phylogenetic signal, sometimes substantially influenced the programs’ relative performance. Our results provide real-world gene and species tree phylogenetic inference benchmarks to inform the design and execution of large-scale phylogenomic data analyses. PMID:29177474

  16. Association between proximity to and coverage of traditional fast-food restaurants and non-traditional fast-food outlets and fast-food consumption among rural adults

    Directory of Open Access Journals (Sweden)

    Horel Scott A

    2011-05-01

    Full Text Available Abstract Objective The objective of this study is to examine the relationship between residential exposure to fast-food entrées, using two measures of potential spatial access: proximity (distance to the nearest location and coverage (number of different locations, and weekly consumption of fast-food meals. Methods Traditional fast-food restaurants and non-traditional fast-food outlets, such as convenience stores, supermarkets, and grocery stores, from the 2006 Brazos Valley Food Environment Project were linked with individual participants (n = 1409 who completed the nutrition module in the 2006 Brazos Valley Community Health Assessment. Results Increased age, poverty, increased distance to the nearest fast food, and increased number of different traditional fast-food restaurants, non-traditional fast-food outlets, or fast-food opportunities were associated with less frequent weekly consumption of fast-food meals. The interaction of gender and proximity (distance or coverage (number indicated that the association of proximity to or coverage of fast-food locations on fast-food consumption was greater among women and opposite of independent effects. Conclusions Results provide impetus for identifying and understanding the complex relationship between access to all fast-food opportunities, rather than to traditional fast-food restaurants alone, and fast-food consumption. The results indicate the importance of further examining the complex interaction of gender and distance in rural areas and particularly in fast-food consumption. Furthermore, this study emphasizes the need for health promotion and policy efforts to consider all sources of fast-food as part of promoting healthful food choices.

  17. Association between proximity to and coverage of traditional fast-food restaurants and non-traditional fast-food outlets and fast-food consumption among rural adults

    Science.gov (United States)

    2011-01-01

    Objective The objective of this study is to examine the relationship between residential exposure to fast-food entrées, using two measures of potential spatial access: proximity (distance to the nearest location) and coverage (number of different locations), and weekly consumption of fast-food meals. Methods Traditional fast-food restaurants and non-traditional fast-food outlets, such as convenience stores, supermarkets, and grocery stores, from the 2006 Brazos Valley Food Environment Project were linked with individual participants (n = 1409) who completed the nutrition module in the 2006 Brazos Valley Community Health Assessment. Results Increased age, poverty, increased distance to the nearest fast food, and increased number of different traditional fast-food restaurants, non-traditional fast-food outlets, or fast-food opportunities were associated with less frequent weekly consumption of fast-food meals. The interaction of gender and proximity (distance) or coverage (number) indicated that the association of proximity to or coverage of fast-food locations on fast-food consumption was greater among women and opposite of independent effects. Conclusions Results provide impetus for identifying and understanding the complex relationship between access to all fast-food opportunities, rather than to traditional fast-food restaurants alone, and fast-food consumption. The results indicate the importance of further examining the complex interaction of gender and distance in rural areas and particularly in fast-food consumption. Furthermore, this study emphasizes the need for health promotion and policy efforts to consider all sources of fast-food as part of promoting healthful food choices. PMID:21599955

  18. The evolution of single stars

    International Nuclear Information System (INIS)

    Tayler, R.J.

    1982-01-01

    The general outline of the evolution of single stars is well understood but at most stages of evolution important uncertainties remain. This paper contains a very personal view of what are the major uncertainties and of what problems remain to be solved before one can be satisfied with the theory. It is suggested that some problems may be essentially insoluble even with the very large and fast computers that are currently available. (author)

  19. Fast ejendom III

    DEFF Research Database (Denmark)

    Munk-Hansen, Carsten

    Bogen er det tredje bind af tre planlagte bind om fast ejendom: I Overdragelsen, II Bolighandlen og III Ejerbeføjelsen. Fremstillingens giver et grundigt overblik over centrale områder af en omfattende regulering af fast ejendom, med angivelse af litteratur, hvor læseren kan søge yderligere...... oplysning. En ejer af fast ejendom er på særdeles mange områder begrænset i sin råden sammenlignet med ejeren af et formuegode i almindelighed. Fremstillingen tager udgangspunkt i ejerens perspektiv (fremfor samfundets eller myndighedernes). Både den privatretlige og offentligretlige regulering behandles......, eksempelvis ejendomsdannelsen, servitutter, naboretten, hævd, zoneinddelingen, den fysiske planlægning, beskyttelse af natur, beskyttelse af kultur, forurening fra fast ejendom, erstatning for forurening, jordforurening, ekspropriation, byggeri og adgang til fast ejendom....

  20. Fasting and rheumatic diseases

    OpenAIRE

    Mohammad Hassan Jokar

    2015-01-01

    Fasting is one of the important religious practices of Muslims, in which the individuals abstain from eating and drinking from dawn to sunset. Fasting is not obligatory or even not allowed, in case it causes health problems to the fasting individual. Rheumatic diseases are a major group of chronic diseases which can bring about numerous problems while fasting. The aim of this article is to review the impact of Islamic fasting on rheumatic patients, based on the scientific evidences.

  1. Fast ADC interface with data reduction facilities for multi-parameter experiments in nuclear physics

    Energy Technology Data Exchange (ETDEWEB)

    Liebl, W; Franz, N; Ziegler, G [Technische Univ. Muenchen, Garching (Germany, F.R.). Fakultaet Physik; Hegewisch, S; Kunz, D; Maier, D; Lutter, R; Schoeffel, K; Stanzel, B [Muenchen Univ. (Germany, F.R.). Sektion Physik; Drescher, B [Hahn-Meitner-Institut fuer Kernforschung Berlin G.m.b.H. (Germany, F.R.)

    1982-03-01

    A modular ADC interface system for multi-parameter experiments with single NIM ADCs is described. 16 fast ADCs are handled by CAMAC modules and data buses in order to build up a sophisticated hardware system which is able to take coincidence data and singles spectra in parallel. The coincidence logic is handled by one of the interface modules; the interface allows online data reduction. The further expansion of the system will be discussed.

  2. Verification and Validation of Multisegmented Mooring Capabilities in FAST v8: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, Morten T.; Wendt, Fabian; Robertson, Amy; Jonkman, Jason; Hall, Matthew

    2016-08-01

    The quasi-static and dynamic mooring modules of the open-source aero-hydro-servo-elastic wind turbine simulation software, FAST v8, have previously been verified and validated, but only for mooring arrangements consisting of single lines connecting each fairlead and anchor. This paper extends the previous verification and validation efforts to focus on the multisegmented mooring capability of the FAST v8 modules: MAP++, MoorDyn, and the OrcaFlex interface. The OC3-Hywind spar buoy system tested by the DeepCwind consortium at the MARIN ocean basin, which includes a multisegmented bridle layout of the mooring system, was used for the verification and validation activities.

  3. Fast detection of atrazine in corn using thermometric biosensors.

    Science.gov (United States)

    Qie, Zhiwei; Ning, Baoan; Liu, Ming; Bai, Jialei; Peng, Yuan; Song, Nan; Lv, Zhiqiang; Wang, Ying; Sun, Siming; Su, Xuan; Zhang, Yihong; Gao, Zhixian

    2013-09-07

    Fast detection is important in screening large-scale samples. This study establishes a direct competitive ELISA method (dcTELISA) based on an enzyme thermistor for fast atrazine (ATZ) detection. ATZ competes with β-lactamase-labeled ATZ (ATZ-E) for the binding sites on anti-ATZ monoclonal antibody (mAb). The mAb are covalently bound to Controlled Pore Glass (CPG) in an immunoreactor to form immunocomplexes with ATZ and ATZ-E. Several parameters of biosensor performance were optimized, such as the ATZ-E concentration, concentration and nature of the substrate, flow rate, and effect of temperature on the sensor response. After optimization, the assay time for a single sample was 12 min. The work process and result were compared with those of high-performance liquid chromatography (HPLC). The detection results exhibited a recovery rate of 88% to 107% in ATZ-spiked fresh cut corn stalks and silage samples. The results obtained via dcTELISA had good correlation with that of HPLC, and the biosensor response was reproducible and stable even when used continuously for over 4 months. All these properties suggested that the fast detection method, dcTELISA, may be used to detect pesticide residue in large-scale samples.

  4. POD-Galerkin Model for Incompressible Single-Phase Flow in Porous Media

    KAUST Repository

    Wang, Yi; Yu, Bo; Sun, Shuyu

    2017-01-01

    Fast prediction modeling via proper orthogonal decomposition method combined with Galerkin projection is applied to incompressible single-phase fluid flow in porous media. Cases for different configurations of porous media, boundary conditions

  5. Utility of single shot fast spin echo technique in evaluating pancreaticobiliary diseases: T2-weighted image and magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Kim, Myeong Jin; Chung, Jae Bok; Ko, Heung Kyu; Kim, Dong Joon; Kim, Joo Hee; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To evaluate the accuracy of T2-weighted imaging an MR cholangiopancreatography using the single shot fast spin-echo technique for evaluating pancreaticobiliary disease. Between March and July 1997, axial and coronal T2-weighted images(TE: 80-200 msec) and MR cholangiopancreatograms (TE: 800-1200 msec) were obtained in two ways [single slab (thickness: 30-50 mm) and multislice acquisition under chemical fat saturation] using SSFSE pulse sequencing in 131 cases of suspected pancreati-cobiliary disease. The accuracy of SSFSE MR imaging was assessed in 89 lesions of 74 patients [male, 48; female, 26; age range, 30-86 (mean, 59) years] confirmed surgicopathologically (50 lesions in 39 patients) and clinically (39 lesions in 35 patients). Two radiologists reviewed the MR images and diagnosis was determined by consensus. Correct diagnosis was confirmed in 84 of 89 lesions (94%). Seven lesions were falsely interpreted, false positive and false negative results accounting for two and five cases, respectively. Two pancreatic cancers were misdiagnosed as pancreatitis and a cancer of the proximal common bile duct(CBD) was interpreted as a distal CBD cancer. The sensitivity of SSFSE MR imaging for malignancy was 93 %. One CBD stone revealed by endoscopic retrograde cholangiopancreatography (ERCP) was not detected on MR images. In contrast, a stone in the CBD seen on MR images was not apparent on subsequent ERCP. Sensitivity and specificity for calculous disease were 96% and 99.7%, respectively. A benign stricture of the ampulla of Vater was falsely interpreted as normal, and correct diagnosis was possible in two falsely diagnosed cases when MR images were reviewed retrospectively. The combination of T2-weighted and cholangiographic images using SSFSE is an accurate method for diagnosing pancreatcobiliary diseases

  6. On the problem of monitoring the neutron parameters of the Fast Energy Amplifier

    International Nuclear Information System (INIS)

    Behringer, K.; Wydler, P.

    1998-10-01

    The conceptual Fast Energy Amplifier, proposed by Rubbia et al. (1995), consists of a combination of a U-233/Th-232 fuelled fast-neutron subcritical facility with a proton accelerator. An intense beam of 1 GeV protons is injected into liquid lead at the core centre and drives the reactor by producing spallation neutrons. The burst of spallation neutrons produced by a single proton alters the basic neutron statistics which are well known for thermal neutrons in conventional nuclear reactors. A short assessment of standard neutron noise analysis methods is made with respect to monitoring neutron parameter data. (author)

  7. Do singles or couples live healthier lifestyles? Trends in Queensland between 2005-2014.

    Science.gov (United States)

    Schoeppe, Stephanie; Vandelanotte, Corneel; Rebar, Amanda L; Hayman, Melanie; Duncan, Mitch J; Alley, Stephanie J

    2018-01-01

    To compare the frequency of and trends in healthy lifestyle factors between singles and couples. Cross-sectional data from annual surveys conducted from 2005-2014 were used. The pooled sample included 15,001 Australian adults (mean age: 52.9 years, 50% male, 74% couples) who participated in the annual Queensland Social Survey via computer-assisted telephone interviews. Relationship status was dichotomised into single and couple. Binary logistic regression was used to assess associations between relationship status, and the frequency of and trends in healthy lifestyle factors. Compared to singles, couples were significantly more likely to be a non-smoker (OR = 1.82), and meet recommendations for limited fast food (OR = 1.12), alcohol consumption (OR = 1.27) and fruit and vegetable intake (OR = 1.24). Fruit and vegetable intake was not significantly associated with relationship status after adjusting for the other healthy lifestyle factors. Conversely, couples were significantly less likely to be within a normal weight range (OR = 0.81). In both singles and couples, the trend data revealed significant declines in the rates of normal weight (singles: OR = 0.97, couples: OR = 0.97) and viewing TV for less than 14 hours per week (singles: OR = 0.85, couples: OR = 0.84), whilst non-smoking rates significantly increased (singles: OR = 1.12, couples: OR = 1.03). The BMI trend was no longer significant when adjusting for health behaviours. Further, in couples, rates of meeting recommendations for physical activity and fruit/vegetable consumption significantly decreased (OR = 0.97 and OR = 0.95, respectively), as did rates of eating no fast food (OR = 0.96). These trends were not significant when adjusting for the other healthy lifestyle factors. In singles, rates of meeting alcohol recommendations significantly increased (OR = 1.08). Health behaviour interventions are needed in both singles and couples, but relationship status needs to be considered in interventions

  8. The effect of energy and traffic light labelling on parent and child fast food selection: a randomised controlled trial.

    Science.gov (United States)

    Dodds, Pennie; Wolfenden, Luke; Chapman, Kathy; Wellard, Lyndal; Hughes, Clare; Wiggers, John

    2014-02-01

    Labelling of food from fast food restaurants at point-of-purchase has been suggested as one strategy to reduce population energy consumption and contribute to reductions in obesity prevalence. The aim of this study was to examine the effects of energy and single traffic light labelling systems on the energy content of child and adult intended food purchases. The study employed a randomised controlled trial design. English speaking parents of children aged between three and 12 years were recruited from an existing research cohort. Participants were mailed one of three hypothetical fast food menus. Menus differed in their labelling technique – either energy labels, single traffic light labels, or a no-label control. Participants then completed a telephone survey which assessed intended food purchases for both adult and child. The primary trial outcome was total energy of intended food purchase. A total of 329 participants completed the follow-up telephone interview. Eighty-two percent of the energy labelling group and 96% of the single traffic light labelling group reported noticing labelling information on their menu. There were no significant differences in total energy of intended purchases of parents, or intended purchases made by parents for children, between the menu labelling groups, or between menu labelling groups by socio-demographic subgroups. This study provided no evidence to suggest that energy labelling or single traffic light labelling alone were effective in reducing the energy of fast food items selected from hypothetical fast food menus for purchase. Additional complementary public health initiatives promoting the consumption of healthier foods identified by labelling, and which target other key drivers of menu item selection in this setting may be required.

  9. Single bunched beam generation without subharmonic prebuncher

    International Nuclear Information System (INIS)

    Kobayashi, T.; Tagawa, S.

    1995-01-01

    The intensity of the accelerated single bunched electron beam depends on the performance of the electron gun and the fast cathode pulser. The electron beam is emitted by a Y-796 cathode assembly with a cathode of 2 cm 2 (8 A/cm 2 ), and an extracted voltage of 90 kV. The maximum charge of the single bunched beam was attained at 1.5 nC/pulse using SHB. Recently, a single bunched beam has been generated by an ultrafast cathode pulser (rise and fall time <100 ps pulse height -2 kV at 50 Ω) without SHB. The charge of the accelerated electron beam is about 40 pC/pulse (pulse width <10 ps) without the production of a satellite beam. This result show that a single bunched beam can be produced by the linear accelerator without SHB. ((orig.))

  10. Design of a single variable helium effects experiment for irradiation in FFTF [Fast Flux Test Facility] using alloys enriched in nickel 59

    International Nuclear Information System (INIS)

    Simons, R.L.; Brager, H.R.; Matsumoto, W.Y.

    1986-03-01

    Nickel enriched in nickel 59 was extracted from the fragments of a fracture toughness specimen of Inconel 600 irradiated in the Engineering Test Reactor (ETR). The nickel contained 2.0% nickel 59. Three heats of austenitic steel doped with nickel-59 were prepared and inserted in the Materials Open Test Assembly (MOTA) of the Fast Flux Test Facility (FFTF). The experiment was single variable in helium effects because chemically identical alloys without nickel-59 were being irradiated side by side with the doped material. The alloys doped with nickel 59 produced 10 to 100 times more helium than the control alloys. The materials included ternary and quaternary alloys in the form of transmission electron microscope (TEM) discs and miniature tensile specimens. The helium to dpa ratio was in the range 5 to 35 and was nearly constant throughout the irradiation. The exposures ranged from 0.25 to 50 displacements per atom (dpa) over the duration of the experiment. The irradiation temperatures covered the range of 360 to 600 0 C

  11. Fast shower simulation in the ATLAS calorimeter

    International Nuclear Information System (INIS)

    Barberio, E; Boudreau, J; Mueller, J; Tsulaia, V; Butler, B; Young, C C; Cheung, S L; Savard, P; Dell'Acqua, A; Simone, A D; Gallas, M V; Ehrenfeld, W; Glazov, A; Placakyte, R; Marshall, Z; Rimoldi, A; Waugh, A

    2008-01-01

    The time to simulate pp collisions in the ATLAS detector is largely dominated by the showering of electromagnetic particles in the heavy parts of the detector, especially the electromagnetic barrel and endcap calorimeters. Two procedures have been developed to accelerate the processing time of electromagnetic particles in these regions: (1) a fast shower parameterisation and (2) a frozen shower library. Both work by generating the response of the calorimeter to electrons and positrons with Geant 4, and then reintroduce the response into the simulation at runtime. In the fast shower parameterisation technique, a parameterisation is tuned to single electrons and used later by simulation. In the frozen shower technique, actual showers from low-energy particles are used in the simulation. Full Geant 4 simulation is used to develop showers down to ∼ 1GeV, at which point the shower is terminated by substituting a frozen shower. Judicious use of both techniques over the entire electromagnetic portion of the ATLAS calorimeter produces an important improvement of CPU time. We discuss the algorithms and their performance in this paper

  12. Planar-integrated single-crystalline perovskite photodetectors

    KAUST Repository

    Saidaminov, Makhsud I.

    2015-11-09

    Hybrid perovskites are promising semiconductors for optoelectronic applications. However, they suffer from morphological disorder that limits their optoelectronic properties and, ultimately, device performance. Recently, perovskite single crystals have been shown to overcome this problem and exhibit impressive improvements: low trap density, low intrinsic carrier concentration, high mobility, and long diffusion length that outperform perovskite-based thin films. These characteristics make the material ideal for realizing photodetection that is simultaneously fast and sensitive; unfortunately, these macroscopic single crystals cannot be grown on a planar substrate, curtailing their potential for optoelectronic integration. Here we produce large-area planar-integrated films made up of large perovskite single crystals. These crystalline films exhibit mobility and diffusion length comparable with those of single crystals. Using this technique, we produced a high-performance light detector showing high gain (above 104 electrons per photon) and high gain-bandwidth product (above 108 Hz) relative to other perovskite-based optical sensors.

  13. Reexamination of cross-sections for fast neutrons by computational checking of single material integral experiments

    International Nuclear Information System (INIS)

    Schriewer, J.; Hehn, G.; Mattes, M.

    1976-06-01

    Transmission experiments for fast neutrons and pure materials offer the possibility to check the accuracy of nuclear data compilations by recalculating the measured discharge spectra. In this paper the calculations were mainly based on two Benchmark experiments with pure iron carried out at the Karlsruhe Nuclear Research Center. One of the experiments employed a 252 Cf fission source and spherically symmetric arrangement; the other was based on transmission of an iron cylinder by 14-MeV neutrons from a D+T source. The checking calculations were based on the data compilation ENDF/B-IV (occasionally also ENDF/B-III) and on the transport codes ANISN (1D) and DOT-2 (2D) with lined up ESTOQ (for calculating the first-collision source). The calculations with the Cf source showed good agreement with the results of measurement, whereas the checking of the arrangement with 14 MeV neutrons yielded a marked underestimation of the neutron flux density in the range of 2 MeV up to 14 MeV. The discussion of the results including the choice of codes was done on the basis of a literature review on the Benchmark experiments for iron with fast neutrons carried out until now. (orig.) [de

  14. Fast Spectrum Reactors

    CERN Document Server

    Todd, Donald; Tsvetkov, Pavel

    2012-01-01

    Fast Spectrum Reactors presents a detailed overview of world-wide technology contributing to the development of fast spectrum reactors. With a unique focus on the capabilities of fast spectrum reactors to address nuclear waste transmutation issues, in addition to the well-known capabilities of breeding new fuel, this volume describes how fast spectrum reactors contribute to the wide application of nuclear power systems to serve the global nuclear renaissance while minimizing nuclear proliferation concerns. Readers will find an introduction to the sustainable development of nuclear energy and the role of fast reactors, in addition to an economic analysis of nuclear reactors. A section devoted to neutronics offers the current trends in nuclear design, such as performance parameters and the optimization of advanced power systems. The latest findings on fuel management, partitioning and transmutation include the physics, efficiency and strategies of transmutation, homogeneous and heterogeneous recycling, in addit...

  15. Liver Tumor Segmentation from MR Images Using 3D Fast Marching Algorithm and Single Hidden Layer Feedforward Neural Network

    Directory of Open Access Journals (Sweden)

    Trong-Ngoc Le

    2016-01-01

    Full Text Available Objective. Our objective is to develop a computerized scheme for liver tumor segmentation in MR images. Materials and Methods. Our proposed scheme consists of four main stages. Firstly, the region of interest (ROI image which contains the liver tumor region in the T1-weighted MR image series was extracted by using seed points. The noise in this ROI image was reduced and the boundaries were enhanced. A 3D fast marching algorithm was applied to generate the initial labeled regions which are considered as teacher regions. A single hidden layer feedforward neural network (SLFN, which was trained by a noniterative algorithm, was employed to classify the unlabeled voxels. Finally, the postprocessing stage was applied to extract and refine the liver tumor boundaries. The liver tumors determined by our scheme were compared with those manually traced by a radiologist, used as the “ground truth.” Results. The study was evaluated on two datasets of 25 tumors from 16 patients. The proposed scheme obtained the mean volumetric overlap error of 27.43% and the mean percentage volume error of 15.73%. The mean of the average surface distance, the root mean square surface distance, and the maximal surface distance were 0.58 mm, 1.20 mm, and 6.29 mm, respectively.

  16. Differential diagnosis of pituitary adenomas and Rathke's cleft cysts by diffusion-weighted MRI using single-shot fast spin echo technique

    International Nuclear Information System (INIS)

    Abe, Takumi; Izumiyama, Hitoshi; Fukuda, Ataru; Tanioka, Daisuke; Kunii, Norihiko; Komatsu, Daisuke; Fujita, Shogo; Ukisu, Ryutaro; Moritani, Toshio

    2002-01-01

    The purpose of the present study was to prospectively evaluate the diagnostic ability of diffusion-weighted magnetic resonance imaging (DWI) using single-shot fast spin echo (SSFSE) technique to discriminate pituitary adenomas from Rathke's cleft cysts. DWIs were obtained from 40 patients with pathologically proven pituitary macroadenomas and 15 patients with proven Rathke's cleft cysts. Pituitary adenomas were divided into 27 cases with solid components alone, five with non-hemorrhagic large cysts, and eight with intratumoral hemorrhage. On SSFSE DWI, solid components of pituitary adenomas revealed iso or slightly increased intensity and intratumoral hemorrhage showed higher intensity than normal brain parenchyma, whereas Rathke's cleft cysts and intratumoral cysts demonstrated very low intensity. SSFSE DWI did not display the susceptibility artifacts that are seen close to the skull base and sinonasal cavities on echo planar diffusion imaging. On the basis of our preliminary findings, DWI may enable us to differentiate pituitary adenomas with only solid components and hemorrhagic pituitary adenomas appearing hyperintense on T1-weighted images from Rathke's cleft cysts without administration of gadolinium-DTPA. SSFSE DWI appears to be a useful technique for characterizing pituitary diseases without the susceptibility artifacts. Our study is the first report to demonstrate the identification of pituitary disorders on SSFSE DWI. (author)

  17. Fast-track, ambulatory ultrasound-guided Tru-Cut liver biopsy is feasible and cost-efficient

    DEFF Research Database (Denmark)

    Huang, Chenxi; Lorentzen, Torben; Skjoldbye, Bjørn

    2015-01-01

    INTRODUCTION: Most institutions perform percutaneous liver biopsy with a post-biopsy patient observation period lasting up to eight hours, which is resource-demanding. This study aimed to evaluate the safety of liver biopsy performed in a fast-track set-up with an only one-hour post......-biopsy observation time. METHODS: Patients referred to our institution underwent fast-track ultrasound-guided 18-gauge Tru-Cut liver biopsy procedures. Each single biopsy procedure was followed by a post-procedure observational period of one hour and an additional focused assessment with sonography for trauma before...... safely discharged from our institution. No fatality or long-term complications were found during this study. CONCLUSION: The fast-track approach reported herein is a feasible option when adequate patient information is given. Besides the obvious, positive effect on patient logistics and departmental...

  18. Incompressible SPH (ISPH) with fast Poisson solver on a GPU

    Science.gov (United States)

    Chow, Alex D.; Rogers, Benedict D.; Lind, Steven J.; Stansby, Peter K.

    2018-05-01

    This paper presents a fast incompressible SPH (ISPH) solver implemented to run entirely on a graphics processing unit (GPU) capable of simulating several millions of particles in three dimensions on a single GPU. The ISPH algorithm is implemented by converting the highly optimised open-source weakly-compressible SPH (WCSPH) code DualSPHysics to run ISPH on the GPU, combining it with the open-source linear algebra library ViennaCL for fast solutions of the pressure Poisson equation (PPE). Several challenges are addressed with this research: constructing a PPE matrix every timestep on the GPU for moving particles, optimising the limited GPU memory, and exploiting fast matrix solvers. The ISPH pressure projection algorithm is implemented as 4 separate stages, each with a particle sweep, including an algorithm for the population of the PPE matrix suitable for the GPU, and mixed precision storage methods. An accurate and robust ISPH boundary condition ideal for parallel processing is also established by adapting an existing WCSPH boundary condition for ISPH. A variety of validation cases are presented: an impulsively started plate, incompressible flow around a moving square in a box, and dambreaks (2-D and 3-D) which demonstrate the accuracy, flexibility, and speed of the methodology. Fragmentation of the free surface is shown to influence the performance of matrix preconditioners and therefore the PPE matrix solution time. The Jacobi preconditioner demonstrates robustness and reliability in the presence of fragmented flows. For a dambreak simulation, GPU speed ups demonstrate up to 10-18 times and 1.1-4.5 times compared to single-threaded and 16-threaded CPU run times respectively.

  19. Ramadan, fasting and pregnancy

    DEFF Research Database (Denmark)

    Ahmed, Urfan Zahoor; Lykke, Jacob Alexander

    2014-01-01

    In Islam, the month of Ramadan is a period of fasting lasting 29 or 30 days. Epidemiological studies among Muslims in Denmark have not been conducted, but studies show, that fasting among pregnant Muslim women is common. Fasting does not increase the risk of growth restriction or preterm delivery......, but there are reports of decreased foetal movements. Furthermore, the fasting may have long-term health consequences for the offspring, especially when they reach their middle age. According to Islam and the interpretation, pregnant and breast-feeding women are allowed to postpone the fasting of the month of Ramadan...

  20. Ramadan, faste og graviditet

    DEFF Research Database (Denmark)

    Ahmed, Urfan Zahoor; Lykke, Jacob Alexander

    2014-01-01

    In Islam, the month of Ramadan is a period of fasting lasting 29 or 30 days. Epidemiological studies among Muslims in Denmark have not been conducted, but studies show, that fasting among pregnant Muslim women is common. Fasting does not increase the risk of growth restriction or preterm delivery......, but there are reports of decreased foetal movements. Furthermore, the fasting may have long-term health consequences for the offspring, especially when they reach their middle age. According to Islam and the interpretation, pregnant and breast-feeding women are allowed to postpone the fasting of the month of Ramadan...

  1. Fast filtering algorithm based on vibration systems and neural information exchange and its application to micro motion robot

    International Nuclear Information System (INIS)

    Gao Wa; Zha Fu-Sheng; Li Man-Tian; Song Bao-Yu

    2014-01-01

    This paper develops a fast filtering algorithm based on vibration systems theory and neural information exchange approach. The characters, including the derivation process and parameter analysis, are discussed and the feasibility and the effectiveness are testified by the filtering performance compared with various filtering methods, such as the fast wavelet transform algorithm, the particle filtering method and our previously developed single degree of freedom vibration system filtering algorithm, according to simulation and practical approaches. Meanwhile, the comparisons indicate that a significant advantage of the proposed fast filtering algorithm is its extremely fast filtering speed with good filtering performance. Further, the developed fast filtering algorithm is applied to the navigation and positioning system of the micro motion robot, which is a high real-time requirement for the signals preprocessing. Then, the preprocessing data is used to estimate the heading angle error and the attitude angle error of the micro motion robot. The estimation experiments illustrate the high practicality of the proposed fast filtering algorithm. (general)

  2. TORE SUPRA fast reciprocating radio frequency probe

    International Nuclear Information System (INIS)

    Thomas, C.E. Jr.; Harris, J.H.; Haste, G.R.; Kwon, M.; Goulding, R.H.; Hoffman, D.J.; Saoutic, B.; Becoulet, A.; Fraboulet, D.; Beaumont, B.; Kuus, H.; Ladurelle, L.; Pascal, J.Y.

    1995-01-01

    A fast reciprocating ion cyclotron range of frequencies (ICRF) probe was installed and operated on TORE SUPRA during 1992/1993. The body of the probe was originally used on the ATF experiment at Oak Ridge National Laboratory. The probe was adapted for use on TORE SUPRA, and mounted on one of the two fast reciprocating probe mounts. The probe consists of two orthogonal single-turn wire loops, mounted so that one loop senses toroidal rf magnetic fields and the other senses poloidal rf magnetic fields. The probe began operation in June, 1993. The probe active area is approximately 5 cm long by 2 cm, and the reciprocating mount has a slow stroke (5 cm/s) of 30 cm and a fast stroke (1.5 m/s) of about 10 cm. The probe was operated at distances from the plasma edge ranging from 30 to -5 cm (i.e., inside the last closed flux surface). The probe design, electronics, calibration, data acquisition, and data processing are discussed. First data from the probe are presented as a function of ICRF power, distance from the plasma, loop orientation, and other plasma parameters. Initial data show parametric instabilities do not play an important role for ICRF in the TORE SUPRA edge and scrape-off-layer (SOL) plasmas. Additionally it is observed that the probe signal has little or no dependence on position in the SOL/plasma edge

  3. Fast fission phenomena

    International Nuclear Information System (INIS)

    Gregoire, Christian.

    1982-03-01

    Experimental studies of fast fission phenomena are presented. The paper is divided into three parts. In the first part, problems associated with fast fission processes are examined in terms of interaction potentials and a dynamic model is presented in which highly elastic collisions, the formation of compound nuclei and fast fission appear naturally. In the second part, a description is given of the experimental methods employed, the observations made and the preliminary interpretation of measurements suggesting the occurence of fast fission processes. In the third part, our dynamic model is incorporated in a general theory of the dissipative processes studied. This theory enables fluctuations associated with collective variables to be calculated. It is applied to highly inelastic collisions, to fast fission and to the fission dynamics of compound nuclei (for which a schematic representation is given). It is with these calculations that the main results of the second part can be interpreted [fr

  4. The integration of fast reactor to the fuel cycle in Slovakia

    International Nuclear Information System (INIS)

    Zajac, R.; Darilek, P.; Necas, V.

    2009-01-01

    A very topical problem of nuclear power is the fuel cycle back-end. One of the options is a LWR spent fuel reprocessing and a fissile nuclides re-use in the fast reactor. A large amount of spent fuel has been stored in the power plant intermediate storage during the operation of WWER-440 reactors in Slovakia. This paper is based on an analysis of Pu and minor actinides content in actual WWER-440 spent fuel stored in Slovakia. The next part presents the possibilities of reprocessing and Pu re-use in fast reactor under Slovak conditions. The fuel cycle consisting of the WWER-440 reactor, PUREX reprocessing plant and a sodium fast reactor was designed. The last section compares two parts of this fuel cycle: one is UOX cycle in WWER-440 reactor and the other is cycle in the fast reactor - SUPER PHENIX loaded with MOX fuel (Pu + Minor Actinides). The starting point is a single recycling of Pu from WWER-440 in the fission products. The next step is multi recycling of Pu in the fission products to obtain equilibrium cycle. This article is dealing with the solution of power production and fuel cycle indicators. All kinds of calculations were performed by computer code HELIOS 1.10. (Authors)

  5. The integration of fast reactor to the fuel cycle in Slovakia

    International Nuclear Information System (INIS)

    Zajac, R.; Darilek, P.; Necas, V.

    2009-01-01

    A very topical problem of nuclear power is the fuel cycle back-end. One of the options is a LWR spent fuel reprocessing and a fissile nuclides re-use in the fast reactor. A large amount of spent fuel has been stored in the power plant intermediate storage during the operation of VVER-440 reactors in Slovakia. This paper is based on an analysis of Pu and minor actinides content in actual VVER-440 spent fuel stored in Slovakia. The next part presents the possibilities of reprocessing and Pu re-use in fast reactor under Slovak conditions. The fuel cycle consisting of the VVER-440 reactor, PUREX reprocessing plant and a sodium fast reactor was designed. The last section compares two parts of this fuel cycle: one is UOX cycle in VVER-440 reactor and the other is cycle in the fast reactor - SUPER PHENIX loaded with MOX fuel (Pu + Minor Actinides). The starting point is a single recycling of Pu from VVER-440 in the FR. The next step is multirecycling of Pu in the FR to obtain equilibrium cycle. This article is dealing with the solution of power production and fuel cycle indicators. All kinds of calculations were performed by computer code HELIOS 1.10. (authors)

  6. Fast grasping of unknown objects using principal component analysis

    Science.gov (United States)

    Lei, Qujiang; Chen, Guangming; Wisse, Martijn

    2017-09-01

    Fast grasping of unknown objects has crucial impact on the efficiency of robot manipulation especially subjected to unfamiliar environments. In order to accelerate grasping speed of unknown objects, principal component analysis is utilized to direct the grasping process. In particular, a single-view partial point cloud is constructed and grasp candidates are allocated along the principal axis. Force balance optimization is employed to analyze possible graspable areas. The obtained graspable area with the minimal resultant force is the best zone for the final grasping execution. It is shown that an unknown object can be more quickly grasped provided that the component analysis principle axis is determined using single-view partial point cloud. To cope with the grasp uncertainty, robot motion is assisted to obtain a new viewpoint. Virtual exploration and experimental tests are carried out to verify this fast gasping algorithm. Both simulation and experimental tests demonstrated excellent performances based on the results of grasping a series of unknown objects. To minimize the grasping uncertainty, the merits of the robot hardware with two 3D cameras can be utilized to suffice the partial point cloud. As a result of utilizing the robot hardware, the grasping reliance is highly enhanced. Therefore, this research demonstrates practical significance for increasing grasping speed and thus increasing robot efficiency under unpredictable environments.

  7. Marketing fast food: impact of fast food restaurants in children's hospitals.

    Science.gov (United States)

    Sahud, Hannah B; Binns, Helen J; Meadow, William L; Tanz, Robert R

    2006-12-01

    The objectives of this study were (1) to determine fast food restaurant prevalence in hospitals with pediatric residencies and (2) to evaluate how hospital environment affects purchase and perception of fast food. We first surveyed pediatric residency programs regarding fast food restaurants in their hospitals to determine the prevalence of fast food restaurants in these hospitals. We then surveyed adults with children after pediatric outpatient visits at 3 hospitals: hospital M with an on-site McDonald's restaurant, hospital R without McDonald's on site but with McDonald's branding, and hospital X with neither on-site McDonald's nor branding. We sought to determine attitudes toward, consumption of, and influences on purchase of fast food and McDonald's food. Fifty-nine of 200 hospitals with pediatric residencies had fast food restaurants. A total of 386 outpatient surveys were analyzed. Fast food consumption on the survey day was most common among hospital M respondents (56%; hospital R: 29%; hospital X: 33%), as was the purchase of McDonald's food (hospital M: 53%; hospital R: 14%; hospital X: 22%). McDonald's accounted for 95% of fast food consumed by hospital M respondents, and 83% of them bought their food at the on-site McDonald's. Using logistic regression analysis, hospital M respondents were 4 times more likely than respondents at the other hospitals to have purchased McDonald's food on the survey day. Visitors to hospitals M and R were more likely than those at hospital X to believe that McDonald's supported the hospital financially. Respondents at hospital M rated McDonald's food healthier than did respondents at the other hospitals. Fast food restaurants are fairly common in hospitals that sponsor pediatric residency programs. A McDonald's restaurant in a children's hospital was associated with significantly increased purchase of McDonald's food by outpatients, belief that the McDonald's Corporation supported the hospital financially, and higher rating

  8. A fast ADC interface with data reduction facilities for multi-parameter experiments in nuclear physics

    International Nuclear Information System (INIS)

    Liebl, W.; Franz, N.; Ziegler, G.

    1982-01-01

    A modular ADC interface system for multi-parameter experiments with single NIM ADCs is described. 16 fast ADCs are handled by CAMAC modules and data buses in order to build up a sophisticated hardware system which is able to take coincidence data and singles spectra in parallel. The coincidence logic is handled by one of the interface modules; the interface allows online data reduction. The further expansion of the system will be discussed. (orig.)

  9. Progress and status of the integral fast reactor (IFR) development program

    International Nuclear Information System (INIS)

    Chang, Y.I.

    1992-01-01

    This paper discusses the Integral Fast Reactor (IFR) development program, in which the entire reactor system - reactor, fuel cycle, and waste process is being developed and optimized at the same time as a single integral entity. Detailed discussions on the present status of the IFR technology development activities in the areas of fuels, pyroprocessing, safety, core design, and fuel cycle demonstration are also presented

  10. 3D hybrid profile order technique in a single breath-hold 3D T2-weighted fast spin-echo sequence: Usefulness in diagnosis of small liver lesions.

    Science.gov (United States)

    Hirata, Kenichiro; Nakaura, Takeshi; Okuaki, Tomoyuki; Tsuda, Noriko; Taguchi, Narumi; Oda, Seitaro; Utsunomiya, Daisuke; Yamashita, Yasuyuki

    2018-01-01

    We compared the efficacy of three-dimensional (3D) isotropic T2-weighted fast spin-echo imaging using a 3D hybrid profile order technique with a single-breath-hold (3D-Hybrid BH) with a two-dimensional (2D) T2-weighted fast spin-echo conventional respiratory-gated (2D-Conventional RG) technique for visualising small liver lesions. This study was approved by our institutional review board. The requirement to obtain written informed consent was waived. Fifty patients with small (≤15mm) hepatocellular carcinomas (HCC) (n=26), or benign cysts (n=24), had undergone hepatic MRI including both 2D-Conventional RG and 3D-Hybrid BH. We calculated the signal-to-noise ratio (SNR) and tumour-to-liver contrast (TLC). The diagnostic performance of the two protocols was analysed. The image acquisition time was 89% shorter with the 3D-Hybrid BH than with 2D-Conventional RG. There was no significant difference in the SNR between the two protocols. The area under the curve (AUC) of the TLC was significantly higher on 3D-Hybrid BH than on 2D-Conventional RG. The 3D-Hybrid BH sequence significantly improved diagnostic performance for small liver lesions with a shorter image acquisition time without sacrificing accuracy. Copyright © 2017. Published by Elsevier B.V.

  11. Physiology of Ramadan fasting

    OpenAIRE

    Shokoufeh Bonakdaran

    2016-01-01

    Considering the emphasis of Islam on the importance of fasting, Muslims attempt to fast from dawn until sunset during the holy month of Ramadan. Fasting is associated with several benefits for normal and healthy individuals. However, it could pose high risks to the health of diabetic patients due to certain physiological changes. This study aimed to compare the physiological changes associated with fasting in healthy individuals and diabetic patients during Ramadan. Furthermore, we reviewed t...

  12. Fast Responding Voltage Regulator and Dynamic VAR Compensator

    Energy Technology Data Exchange (ETDEWEB)

    Divan, Deepak [Varentec, Incorporated, San Jose, CA (United States); Moghe, Rohit [Varentec, Incorporated, San Jose, CA (United States); Tholomier, Damien [Varentec, Incorporated, San Jose, CA (United States)

    2014-12-31

    The objectives of this project were to develop a dynamic VAR compensator (DVC) for voltage regulation through VAR support to demonstrate the ability to achieve greater levels of voltage control on electricity distribution networks, and faster response compared to existing grid technology. The goal of the project was to develop a prototype Fast Dynamic VAR Compensator (Fast DVC) hardware device, and this was achieved. In addition to developing the dynamic VAR compensator device, Varentec in partnership with researchers at North Carolina State University (NCSU) successfully met the objectives to model the potential positive impact of such DVCs on representative power networks. This modeling activity validated the ability of distributed dynamic VAR compensators to provide fast voltage regulation and reactive power control required to respond to grid disturbances under high penetration of fluctuating and intermittent distributed energy resources (DERs) through extensive simulation studies. Specifically the following tasks were set to be accomplished: 1) Development of dynamic VAR compensator to support dynamic voltage variations on the grid through VAR control 2) Extensive testing of the DVC in the lab environment 3) Present the operational DVC device to the DOE at Varentec’s lab 4) Formulation of a detailed specification sheet, unit assembly document, test setup document, unit bring-up plan, and test plan 5) Extensive simulations of the DVC in a system with high PV penetration. Understanding the operation with many DVC on a single distribution system 6) Creation and submittal of quarterly and final reports conveying the design documents, unit performance data, modeling simulation charts and diagrams, and summary explanations of the satisfaction of program goals. This report details the various efforts that led to the development of the Fast DVC as well as the modeling & simulation results. The report begins with the introduction in Section II which outlines the

  13. Single Photon Avalanche Diodes: Towards the Large Bidimensional Arrays

    Directory of Open Access Journals (Sweden)

    Emilio Sciacca

    2008-08-01

    Full Text Available Single photon detection is one of the most challenging goals of photonics. In recent years, the study of ultra-fast and/or low-intensity phenomena has received renewed attention from the academic and industrial communities. Intense research activity has been focused on bio-imaging applications, bio-luminescence, bio-scattering methods, and, more in general, on several applications requiring high speed operation and high timing resolution. In this paper we present design and characterization of bi-dimensional arrays of a next generation of single photon avalanche diodes (SPADs. Single photon sensitivity, dark noise, afterpulsing and timing resolution of the single SPAD have been examined in several experimental conditions. Moreover, the effects arising from their integration and the readout mode have also been deeply investigated.

  14. Fast optical signal not detected in awake behaving monkeys.

    Science.gov (United States)

    Radhakrishnan, Harsha; Vanduffel, Wim; Deng, Hong Ping; Ekstrom, Leeland; Boas, David A; Franceschini, Maria Angela

    2009-04-01

    While the ability of near-infrared spectroscopy (NIRS) to measure cerebral hemodynamic evoked responses (slow optical signal) is well established, its ability to measure non-invasively the 'fast optical signal' is still controversial. Here, we aim to determine the feasibility of performing NIRS measurements of the 'fast optical signal' or Event-Related Optical Signals (EROS) under optimal experimental conditions in awake behaving macaque monkeys. These monkeys were implanted with a 'recording well' to expose the dura above the primary visual cortex (V1). A custom-made optical probe was inserted and fixed into the well. The close proximity of the probe to the brain maximized the sensitivity to changes in optical properties in the cortex. Motion artifacts were minimized by physical restraint of the head. Full-field contrast-reversing checkerboard stimuli were presented to monkeys trained to perform a visual fixation task. In separate sessions, two NIRS systems (CW4 and ISS FD oximeter), which previously showed the ability to measure the fast signal in human, were used. In some sessions EEG was acquired simultaneously with the optical signal. The increased sensitivity to cortical optical changes with our experimental setup was quantified with 3D Monte Carlo simulations on a segmented MRI monkey head. Averages of thousands of stimuli in the same animal, or grand averages across the two animals and across repeated sessions, did not lead to detection of the fast optical signal using either amplitude or phase of the optical signal. Hemodynamic responses and visual evoked potentials were instead always detected with single trials or averages of a few stimuli. Based on these negative results, despite the optimal experimental conditions, we doubt the usefulness of non-invasive fast optical signal measurements with NIRS.

  15. Radiosensitivity and repair capacity of two xenografted human soft tissue sarcomas to photons and fast neutrons

    International Nuclear Information System (INIS)

    Budach, V.; Stuschke, M.; Budach, W.; Krause, U.; Streffer, C.; Sack, H.

    1989-01-01

    The radiation response, the relative biological effectiveness (RBE) and sublethal damage repair of two xenografted human soft tissue sarcomas after single doses and fractionated irradiation with 60 Co and 5.8 MeV fast neutrons are presented. (author)

  16. Fast breeder reactors

    International Nuclear Information System (INIS)

    Heinzel, V.

    1975-01-01

    The author gives a survey of 'fast breeder reactors'. In detail the process of breeding, the reasons for the development of fast breeders, the possible breeder reactors, the design criteria, fuels, cladding, coolant, and safety aspects are reported on. Design data of some experimental reactors already in operation are summarized in stabular form. 300 MWe Prototype-Reactors SNR-300 and PFR are explained in detail and data of KWU helium-cooled fast breeder reactors are given. (HR) [de

  17. Fast reactors worldwide

    International Nuclear Information System (INIS)

    Hall, R.S.; Vignon, D.

    1985-01-01

    The paper concerns the evolution of fast reactors over the past 30 years, and their present status. Fast reactor development in different countries is described, and the present position, with emphasis on cost reduction and collaboration, is examined. The French development of the fast breeder type reactor is reviewed, and includes: the acquisition of technical skills, the search for competitive costs and the spx2 project, and more advanced designs. Future prospects are also discussed. (U.K.)

  18. Fast food (image)

    Science.gov (United States)

    Fast foods are quick, reasonably priced, and readily available alternatives to home cooking. While convenient and economical for a busy lifestyle, fast foods are typically high in calories, fat, saturated fat, ...

  19. Techno-Economic Analysis of BEVs with Fast Charging Infrastructure: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Neubauer, J.; Pesaran, A.

    2014-08-01

    Battery electric vehicles (BEVs) offer the potential to reduce both oil imports and greenhouse gas emissions, but high upfront costs, battery-limited vehicle range, and concern over high battery replacement costs may discourage many potential purchasers. One proposed solution is to employ a subscription model under which a service provider assumes ownership of the battery while providing access to vast fast charging infrastructure. Thus, high upfront and subsequent battery replacement costs are replaced by a predictable monthly fee, and battery-limited range is replaced by a larger infrastructure-limited range. Assessing the costs and benefits of such a proposal are complicated by many factors, including customer drive patterns, the amount of required infrastructure, and battery life. Herein the National Renewable Energy Laboratory applies its Battery Ownership Model to address these challenges and compare the economics and utility of a BEV fast charging service plan to a traditional direct ownership option. In single vehicle households, where such a service is most valuable, we find that operating a BEV under a fast charge service plan can be more cost-effective than direct ownership of a BEV, but it is rarely more cost-effective than direct ownership of a conventional vehicle.

  20. Transient Analysis of a Gas-cooled Fast Reactor for Single Control Assembly Withdrawal

    International Nuclear Information System (INIS)

    Choi, Hangbok

    2014-01-01

    The Energy Multiplier Module (EMZ) system response has been evaluated for control assembly withdrawal transients. Currently the EM2 core is equipped with six cylindrical drum-type control assemblies in the reflector zone for excess reactivity control and power maneuvering during the operating core life. This study investigates the system response to the control assembly withdrawal accident with various rotational speeds and reactivity worth to determine feasible control assembly design requirements from the physics viewpoint. The simulations have been conducted for single control assembly withdrawal transients without scram by a gas-cooled reactor plant simulator, which is based on a simplified plant nodal model, including the point reactor kinetics, single channel core thermal-fluid model, and a turbo-machinery performance model. Simulations were conducted for the middle-of- cycle core, when the excess reactivity of the core is the highest. Control assembly withdrawal times were varied from 1 (runaway) to 180 sec and reactivity worth was varied from 100 to 400 pcm. For a single control assembly withdrawal, the simulation has shown that the peak fuel temperature is expected to be ~1820°C when the assembly worth is 200 pcm and the runaway time is 1 sec per 180 degree rotation. The peak temperature could be reduced to ~1780°C if the assembly is rotated out in a moderate speed such as 1 degree/sec. These peak temperatures give a thermal margin of 22 to 24% to the melting point of uranium carbide fuel. The results also indicate that the current design with a single control assembly worth of 314 pcm may need adjustments in the future design. (author)

  1. Bioequivalence of 250 mg lysine clonixinate tablets after a single oral dose in a healthy female Mexican population under fasting conditions.

    Science.gov (United States)

    Marcelín-Jiménez, G; Angeles, A C P; García, A; Morales, M; Rivera, L; Martín-Del-Campo, A

    2010-05-01

    To evaluate the bioequivalence between two 250 mg-tablets of lysine clonixinate, Dorixina Forte (Siegfried Rhein, México) as reference product, and Prestodol (Farmaceúticos Rayere, S.A., México) as test formulation. 26 healthy adult female Mexican volunteers received a single oral dose of 250-mg lysine clonixinate under fasting conditions. The drug was administered following a randomized, two-period, two-sequence, cross-over design. Twelve serial blood samples were collected up to 8 h after dosing, and clonixin (CLX) was measured by ultra-performance liquid chromatography (UPLC) coupled with tandem mass spectrometry. Decimal logarithm values of Cmax and area under the curve (AUC) were used to construct a classic confidence interval at 90% (90% CI). Bioequivalence was established if 90% CI of mean ratios (test/reference) fall within the 0.8-1.25 range. Volunteers formed a homogeneous population in terms of age (27.2 +/- 6.3 years), weight (55.9 +/- 6.5 kg), height (1.6 +/- 0.04 m), and body mass index (BMI) (22.91 +/- 2.03 kg/m(2)). Reference formulation exhibited the following pharmacokinetics: C(max) (32.39 +/- 8.32 microg/ml); t(max) (0.64 +/- 0.2 h); AUC0-8h (48.92 +/- 16.51 microg x h/ml); t1/2 (1.3 +/- 0.24 h); CLapp (5.64 +/- 1.99 l/h), and Vdapp (10.22 +/- 2.9 l). Concerning bioequivalence, 90% CI were: C(max) (82.32 - 98.79), AUC0-t (94.59-106.29), and AUC(0-inf) (94.61-106.42), with a statistical power of > 0.90 at every tested interval. This single-dose study found that both 250-mg immediate-release tablets of lysine clonixinate met the Mexican regulatory criteria for bioequivalence in these volunteers.

  2. Fast radio burst search: cross spectrum vs. auto spectrum method

    Science.gov (United States)

    Liu, Lei; Zheng, Weimin; Yan, Zhen; Zhang, Juan

    2018-06-01

    The search for fast radio bursts (FRBs) is a hot topic in current radio astronomy studies. In this work, we carry out a single pulse search with a very long baseline interferometry (VLBI) pulsar observation data set using both auto spectrum and cross spectrum search methods. The cross spectrum method, first proposed in Liu et al., maximizes the signal power by fully utilizing the fringe phase information of the baseline cross spectrum. The auto spectrum search method is based on the popular pulsar software package PRESTO, which extracts single pulses from the auto spectrum of each station. According to our comparison, the cross spectrum method is able to enhance the signal power and therefore extract single pulses from data contaminated by high levels of radio frequency interference (RFI), which makes it possible to carry out a search for FRBs in regular VLBI observations when RFI is present.

  3. Islamic Fasting and Diabetes

    Directory of Open Access Journals (Sweden)

    Fereidoun Azizi

    2013-07-01

    Full Text Available The aim of this article is to review health-related aspects of Ramadan fasting in normal individuals and diabetics. During fasting days of Ramadan, glucose homeostasis is maintained by meal taken bepore dawn and by liver glycogen stores. Changes in serum lipids are variable and defend on the quality and quantity of food consumption and changes in weight. Compliant, well controlled type 2 diabetics may observe Ramadan fasting; but fasting is not recommended for type 1, non complaint, poorly controlled and pregnant diabetics. Although Ramadan fasting is safe for all healthy individuals and well controlled diabetics, those with uncontrolled diabetics and diabetics with complications should consult physicians and follow scientific recommendations.

  4. Three-Dimensional Imaging by Self-Reference Single-Channel Digital Incoherent Holography

    Science.gov (United States)

    Rosen, Joseph; Kelner, Roy

    2016-01-01

    Digital holography offers a reliable and fast method to image a three-dimensional scene from a single perspective. This article reviews recent developments of self-reference single-channel incoherent hologram recorders. Hologram recorders in which both interfering beams, commonly referred to as the signal and the reference beams, originate from the same observed objects are considered as self-reference systems. Moreover, the hologram recorders reviewed herein are configured in a setup of a single channel interferometer. This unique configuration is achieved through the use of one or more spatial light modulators. PMID:28757811

  5. Dynamic mechanical properties of polymer blends of polypropylene and poly(ethylene-co-vinyl acetate) irradiated with fast electrons

    International Nuclear Information System (INIS)

    Mihaylova, M.; Kresteva, M.; Perena, J; Phillips, P.

    2001-01-01

    Extruded blends of polypropylene and poly(ethylene-co-vinyl acetate) irradiated with fast electrons were studied. The dynamic mechanical properties were investigated with respects to the blend composition and irradiation dose. Two glass transition temperatures corresponding to the glass transitions of the pure components were observed. Their existence is an evidence of immiscibility of the components. Nevertheless, the peaks broadening, the single jump in the storage modulus values and the changes of T g with the blend ratio suggest the creation of an interface region, leading to the improvement of the compatibility of the components. The irradiation with fast electrons at doses higher than 100 KGy results in single T g transition because of the broadening of the interface layer. (authors)

  6. HCUP Fast Stats

    Data.gov (United States)

    U.S. Department of Health & Human Services — HCUP Fast Stats provides easy access to the latest HCUP-based statistics for health information topics. HCUP Fast Stats uses visual statistical displays in...

  7. A simple and effective protocol for fast isolation of human Tenon's fibroblasts from a single trabeculectomy biopsy - a comparison of cell behaviour in different culture media.

    Science.gov (United States)

    Przekora, Agata; Zarnowski, Tomasz; Ginalska, Grazyna

    2017-01-01

    Human Tenon's fibroblasts (HTFs) play a crucial role in wound healing. They cause postoperative scarring of the filtering bleb and are thus responsible for trabeculectomy failure. This study aimed to find an effective and fast protocol for HTF isolation from trabeculectomy biopsies. The protocol was compared with the commonly recommended HTF isolation procedure, which uses Dulbecco's modified Eagle's medium (DMEM). We used Eagle's minimum essential medium (EMEM) enriched with fibroblast growth factor (FGF), which selectively promoted the proliferation of HTF cells. A secondary goal was to compare HTF morphology, metabolism and growth during parallel cultivation of the isolated cells in FGF-enriched EMEM and DMEM. Standard procedures for HTF isolation from tissue biopsies require a 20- to 30-day culture of the explants to obtain the first monolayer. Our protocol yielded the first monolayer after approx. 15 days. More importantly, the majority of the cells were fibroblasts with only individual epithelium-derived cells present. Using FGF-enriched EMEM allowed 1.3 × 10 6 vimentin-positive fibroblasts to be obtained from a single biopsy within approx. 25 days. Using DMEM resulted in isolation failure and required exchange to FGF-enriched medium to recover the fibroblast culture. HTFs maintained in FGF-enriched EMEM also showed faster proliferation and a different type I collagen production ability compared to HTFs cultured in DMEM. Thus, FGF-enriched EMEM is recommended for fast propagation of HTFs unless the aim of the study is to assess the effect of a tested agent on proliferation ability or type I collagen production. Our fast protocol for HTF isolation allows easy setup of cell banks by researchers under laboratory conditions and could be very useful during testing of novel ophthalmologic anti-fibrotic agents in vitro. Molecular analysis of HTFs isolated from patients with known treatment histories may provide valuable information on the effects of some

  8. Fast Fiber-Coupled Imaging Devices

    Energy Technology Data Exchange (ETDEWEB)

    Brockington, Samuel; Case, Andrew; Witherspoon, Franklin

    2018-04-22

    metal pillars in the path of the plasma jets were recorded in a single shot. This new fast imaging system is an attractive alternative to conventional fast framing cameras for applications and experiments where imaging events using existing techniques are inefficient or impossible. The development of HyperV's new diagnostic was split into two tracks: a next generation camera track, in which HyperV built, tested, and demonstrated a prototype 1024 channel camera at its own facility, and a second plasma community beta test track, where selected plasma physics programs received small systems of a few test pixels to evaluate the expected performance of a full scale camera on their experiments. These evaluations were performed as part of an unfunded collaboration with researchers at Los Alamos National Laboratory and the University of California at Davis. Results from the prototype 1024-pixel camera are discussed, as well as results from the collaborations with test pixel system deployment sites.

  9. [Measurement of the frontal and prefrontal lobe volumes in children with malnutrition by three dimensional magnetic resonance imaging scan].

    Science.gov (United States)

    Kanemura, Hideaki; Aihara, Masao; Nakazawa, Shinpei

    2002-09-01

    To evaluate the effects of malnutrition in early life on the growth of the frontal and prefrontal lobes, we quantitatively measured the volumes of the frontal and prefrontal lobes by three dimensional (3-D) MRI in three children (1 year 2 months to 2 years 5 months) with malnutrition. The 3-D MRI data were acquired by the fast spoiled gradient recalled (SPGR) sequence using a 1.5T MR imager. The frontal and prefrontal lobe volumes were measured by the volume measurement function of the Workstation. The data obtained were compared with those of 16 normal subjects (13 children aged 5 months to 14 years, and 3 adults aged 27 to 39 years). The volumes of the frontal and prefrontal lobes in the subjects were smaller compared with age matched controls. The results suggest that malnutrition in early life affects the growth of the frontal and prefrontal lobes.

  10. Fast-prototyping of VLSI

    International Nuclear Information System (INIS)

    Saucier, G.; Read, E.

    1987-01-01

    Fast-prototyping will be a reality in the very near future if both straightforward design methods and fast manufacturing facilities are available. This book focuses, first, on the motivation for fast-prototyping. Economic aspects and market considerations are analysed by European and Japanese companies. In the second chapter, new design methods are identified, mainly for full custom circuits. Of course, silicon compilers play a key role and the introduction of artificial intelligence techniques sheds a new light on the subject. At present, fast-prototyping on gate arrays or on standard cells is the most conventional technique and the third chapter updates the state-of-the art in this area. The fourth chapter concentrates specifically on the e-beam direct-writing for submicron IC technologies. In the fifth chapter, a strategic point in fast-prototyping, namely the test problem is addressed. The design for testability and the interface to the test equipment are mandatory to fulfill the test requirement for fast-prototyping. Finally, the last chapter deals with the subject of education when many people complain about the lack of use of fast-prototyping in higher education for VLSI

  11. A prospective audit of preprocedural fasting practices on a transplant ward: when fasting becomes starving.

    Science.gov (United States)

    Vidot, Helen; Teevan, Kate; Carey, Sharon; Strasser, Simone; Shackel, Nicholas

    2016-03-01

    To investigate the prevalence and duration of preprocedural medically ordered fasting during a period of hospitalisation in an Australian population of patients with hepatic cirrhosis or following liver transplantation and to identify potential solutions to reduce fasting times. Protein-energy malnutrition is a common finding in patients with hepatic cirrhosis and can impact significantly on survival and quality of life. Protein and energy requirements in patients with cirrhosis are higher than those of healthy individuals. A significant feature of cirrhosis is the induction of starvation metabolism following seven to eight hours of food deprivation. Many investigative and interventional procedures for patients with cirrhosis necessitate a period of fasting to comply with anaesthesia guidelines. An observational study of the fasting episodes for 34 hospitalised patients with hepatic cirrhosis or following liver transplantation. Nutritional status was estimated using subjective global assessment and handgrip strength. The prevalence and duration of fasting practices for diagnostic or investigational procedures were estimated using electronic records and patient notes. Thirty-three patients (97%) were malnourished. Twenty-two patients (65%) were fasted during the observation period. There were 43 occasions of fasting with a median fasting time of 13·5 hours. On 40 occasions fasting times exceeded the maximum six-hour guideline recommended prior to the administration of anaesthesia by the majority of Anaesthesiology Societies. The majority of procedures (77%) requiring fasting occurred after midday. Eating breakfast on the day of the procedure reduced fasting time by 45%. Medically ordered preprocedural fasting times almost always exceed existing guidelines in this nutritionally compromised group. Adherence to fasting guidelines and eating breakfast before the procedure can reduce fasting times significantly and avoid the potential induction of starvation metabolism

  12. A review of fast reactor programme in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Masuno, Y [Experimental Fast Reactor Division, O-arai Engineering Center, PNC (Japan); Bando, S [Project Planning and Management Division, PNC, Minato-ku, Tokyo (Japan)

    1981-05-01

    The fast breeder reactor development project in Japan has been in progress in the past twelve months and will be continued in the next fiscal year, from April 1981 through March 1982, at a similar scale of effort both in budget and personnel to those of the fiscal year of 1980. The 1981 year budget for P and D work and for construction of a prototype fast breeder reactor, Monju, will be approximately 20 and 27 billion Yen respectively, excluding wages of the personnel of the Power Reactor and Nuclear Fuel Development Corporation, PNC. The number of the technical people currently engaging in the fast breeder reactor development in the PNC is approximately 530, excluding those working for plutonium fuel fabrication. Concerning the experimental fast reactor, Joyo, power increase from 50 MWt to 75 MWt was made in July 1979 and three operational cycles at 75 MWt have been completed in August 1980 and the forth cycle has started in the middle of March 1981. With respect to the prototype reactor Monju, progress toward construction has been made and an environmental impact statement of the reactor was approved by the concerned authorities. Preliminary design studies of large LMFBR are being made by PNC and also by utilities. A design study being conducted by PNC is on a 1000 MW e plant of loop type by extrapolating the technology to be developed by the time of commissioning of Monju. A group of utilities is conducting a similar study, but covering somewhat wider range of parameters and options of design. Close contact between the group and PNC has been kept. In the future, those design efforts will be combined as a single design effort, when a major effort for developing a large demonstration reactor will be initiated at around the commencement of construction of the prototype reactor Monju. Highlights and topics of the fast breeder reactor development activities in the past twelve months are summarized in this report.

  13. A review of fast reactor programme in Japan

    International Nuclear Information System (INIS)

    Masuno, Y.; Bando, S.

    1981-01-01

    The fast breeder reactor development project in Japan has been in progress in the past twelve months and will be continued in the next fiscal year, from April 1981 through March 1982, at a similar scale of effort both in budget and personnel to those of the fiscal year of 1980. The 1981 year budget for P and D work and for construction of a prototype fast breeder reactor, Monju, will be approximately 20 and 27 billion Yen respectively, excluding wages of the personnel of the Power Reactor and Nuclear Fuel Development Corporation, PNC. The number of the technical people currently engaging in the fast breeder reactor development in the PNC is approximately 530, excluding those working for plutonium fuel fabrication. Concerning the experimental fast reactor, Joyo, power increase from 50 MWt to 75 MWt was made in July 1979 and three operational cycles at 75 MWt have been completed in August 1980 and the forth cycle has started in the middle of March 1981. With respect to the prototype reactor Monju, progress toward construction has been made and an environmental impact statement of the reactor was approved by the concerned authorities. Preliminary design studies of large LMFBR are being made by PNC and also by utilities. A design study being conducted by PNC is on a 1000 MW e plant of loop type by extrapolating the technology to be developed by the time of commissioning of Monju. A group of utilities is conducting a similar study, but covering somewhat wider range of parameters and options of design. Close contact between the group and PNC has been kept. In the future, those design efforts will be combined as a single design effort, when a major effort for developing a large demonstration reactor will be initiated at around the commencement of construction of the prototype reactor Monju. Highlights and topics of the fast breeder reactor development activities in the past twelve months are summarized in this report

  14. The fast breeder reactor

    International Nuclear Information System (INIS)

    Collier, J.

    1990-01-01

    The arguments for and against the fast breeder reactor are debated. The case for the fast reactor is that the world energy demand will increase due to increasing population over the next forty years and that the damage to the global environment from burning fossil fuels which contribute to the greenhouse effect. Nuclear fission is the only large scale energy source which can achieve a cut in the use of carbon based fuels although energy conservation and renewable sources will also be important. Fast reactors produce more energy from uranium than other types of (thermal) reactors such as AGRs and PWRs. Fast reactors would be important from about 2020 onwards especially as by then many thermal reactors will need to be replaced. Fast reactors are also safer than normal reactors. The arguments against fast reactors are largely economic. The cost, especially the capital cost is very high. The viability of the technology is also questioned. (UK)

  15. The fast breeder reactor

    International Nuclear Information System (INIS)

    Davis, D.A.; Baker, M.A.W.; Hall, R.S.

    1990-01-01

    Following submission of written evidence, the Energy Committee members asked questions of three witnesses from the Central Electricity Generating Board and Nuclear Electric (which will be the government owned company running nuclear power stations after privatisation). Both questions and answers are reported verbatim. The points raised include where the responsibility for the future fast reactor programme should lie, with government only or with private enterprise or both and the viability of fast breeder reactors in the future. The case for the fast reactor was stated as essentially strategic not economic. This raised the issue of nuclear cost which has both a construction and a decommissioning element. There was considerable discussion as to the cost of building a European Fast reactor and the cost of the electricity it would generate compared with PWR type reactors. The likely demand for fast reactors will not arrive for 20-30 years and the need to build a fast reactor now is questioned. (UK)

  16. Relative bioavailability of generic and branded acetylcysteine effervescent tablets: A single-dose, open-label, randomized-sequence, two-period crossover study in fasting healthy Chinese male volunteers.

    Science.gov (United States)

    Liu, Yan-Mei; Liu, Yun; Lu, Chuan; Jia, Jing-Ying; Liu, Gang-Yi; Weng, Li-Ping; Wang, Jia-Yan; Li, Guo-Xiu; Wang, Wei; Li, Shui-Jun; Yu, Chen

    2010-11-01

    Acetylcysteine may be used as a muco- lytic agent for the treatment of chronic bronchitis, chronic obstructive pulmonary disease, and other pulmonary diseases complicated by the production of viscous mucus. However, little is known of its pharmacokinetic properties when given orally in healthy volunteers, particularly in a Chinese Han population. This study was conducted to provide support for the marketing of a generic product in China. The purpose of this study was to compare the pharmacokinetics and relative bioavailability of a generic test formulation and a branded reference formulation of acetylcysteine in fasting healthy Chinese male volunteers. A single-dose, open-label, randomized-sequence, 2-period crossover design with a 7-day washout period between doses was used in this study. Healthy Chinese male nonsmokers aged 18 to 40 years with a body mass index (BMI) of 19 to 25 kg/m(2) were selected. Eligible volunteers were randomly assigned to receive acetylcysteine 600 mg PO as either the test formulation (3 tablets of 200 mg each) or reference formulation (1 tablet of 600 mg) under fasting conditions. A total of 15 serial blood samples were collected over a 24-hour interval, and total plasma acetylcysteine concentrations were analyzed by a validated liquid chromatography-isotopic dilution mass spectrometry method. Pharmacokinetic parameters (C(max), T(max), t(½) AUC(0-t), and AUC(0-∞) were calculated and analyzed statistically. The 2 formulations were considered bioequivalent if the 90% CIs of the log-transformed ratios (test/reference) of C(max) and AUC were within the predetermined bioequivalence ranges (70%-143% for C(max); 80%-125% for AUC), as established by the State Food and Drug Administration of China. Tolerability was determined by vital signs, clinical laboratory tests, 12-lead ECGs, physical examinations, and interviews with the subjects about adverse events (AEs). A total of 24 healthy Chinese Han male volunteers were enrolled in and

  17. Detection of optic nerve atrophy following a single episode of unilateral optic neuritis by MRI using a fat-saturated short-echo fast FLAIR sequence

    International Nuclear Information System (INIS)

    Hickman, S.J.; Brex, P.A.; Silver, N.C.; Barker, G.J.; Miller, D.H.; Brierley, C.M.H.; Compston, D.A.S.; Scolding, N.J.; Moseley, I.F.; Plant, G.T.

    2001-01-01

    We describe an MRI technique for quantifying optic nerve atrophy resulting from a single episode of unilateral optic neuritis. We imaged 17 patients, with a median time since onset of optic neuritis of 21 months (range 3-81 months), using a coronal-oblique fat-saturated short-echo fast fluid-attenuated inversion-recovery (sTE fFLAIR) sequence. The mean cross-sectional area of the intraorbital portion of the optic nerves was calculated by a blinded observer from five consecutive 3 mm slices from the orbital apex forwards using a semiautomated contouring technique and compared with data from 16 controls. The mean optic nerve area was 11.2mm 2 in the affected eye of the patients, 12.9mm 2 in the contralateral eye (P = 0.006 compared to the affected eye) and 12.8mm 2 in controls (P = 0.03 compared to the affected eyes). There was a significant negative correlation between disease duration and the size of the affected optic nerve (r = -0.59, P = 0.012). The measurement coefficient of variation was 4.8 %. The sTE fFLAIR sequence enables measurement of optic nerve area with sufficient reproducibility to show optic nerve atrophy following a single episode of unilateral optic neuritis. The correlation of increasing optic nerve atrophy with disease duration would be consistent with ongoing axonal loss in a persistently demyelinated lesion, or Wallerian degeneration following axonal damage during the acute inflammatory phase. (orig.)

  18. Ramadan, fasting and pregnancy

    DEFF Research Database (Denmark)

    Ahmed, Urfan Zahoor; Lykke, Jacob Alexander

    2014-01-01

    In Islam, the month of Ramadan is a period of fasting lasting 29 or 30 days. Epidemiological studies among Muslims in Denmark have not been conducted, but studies show, that fasting among pregnant Muslim women is common. Fasting does not increase the risk of growth restriction or preterm delivery...

  19. Fast reactors

    International Nuclear Information System (INIS)

    Vasile, A.

    2001-01-01

    Fast reactors have capacities to spare uranium natural resources by their breeding property and to propose solutions to the management of radioactive wastes by limiting the inventory of heavy nuclei. This article highlights the role that fast reactors could play for reducing the radiotoxicity of wastes. The conversion of 238 U into 239 Pu by neutron capture is more efficient in fast reactors than in light water reactors. In fast reactors multi-recycling of U + Pu leads to fissioning up to 95% of the initial fuel ( 238 U + 235 U). 2 strategies have been studied to burn actinides: - the multi-recycling of heavy nuclei is made inside the fuel element (homogeneous option); - the unique recycling is made in special irradiation targets placed inside the core or at its surroundings (heterogeneous option). Simulations have shown that, for the same amount of energy produced (400 TWhe), the mass of transuranium elements (Pu + Np + Am + Cm) sent to waste disposal is 60,9 Kg in the homogeneous option and 204.4 Kg in the heterogeneous option. Experimental programs are carried out in Phenix and BOR60 reactors in order to study the feasibility of such strategies. (A.C.)

  20. Fast wave current drive

    International Nuclear Information System (INIS)

    Goree, J.; Ono, M.; Colestock, P.; Horton, R.; McNeill, D.; Park, H.

    1985-07-01

    Fast wave current drive is demonstrated in the Princeton ACT-I toroidal device. The fast Alfven wave, in the range of high ion-cyclotron harmonics, produced 40 A of current from 1 kW of rf power coupled into the plasma by fast wave loop antenna. This wave excites a steady current by damping on the energetic tail of the electron distribution function in the same way as lower-hybrid current drive, except that fast wave current drive is appropriate for higher plasma densities

  1. Positron annihilation study of vacancy-type defects in fast-neutron-irradiated MgO·nAl2O3

    Science.gov (United States)

    Rahman, Abu Zayed Mohammad Saliqur; Li, Zhuoxin; Cao, Xingzhong; Wang, Baoyi; Wei, Long; Xu, Qiu; Atobe, Kozo

    2014-09-01

    The positron lifetimes of fast-neutron-irradiated MgO·nAl2O3 single crystals were measured to investigate the formation of cation vacancies. Al monovacancy was possibly observed in samples irradiated by fast neutrons at ultra-low temperatures. Additionally, vacancy-oxygen complex centers were possibly observed in samples irradiated at higher temperatures and fast neutron fluences. Coincidence Doppler broadening (CDB) spectra were measured to obtain information regarding the vicinity of vacancy-type defects. A peak at approximately 11 × 10-3 m0c was observed, which may be due to the presence of oxygen atoms in the neighborhood of the vacancies.

  2. Metabolic Effects of Intermittent Fasting.

    Science.gov (United States)

    Patterson, Ruth E; Sears, Dorothy D

    2017-08-21

    The objective of this review is to provide an overview of intermittent fasting regimens, summarize the evidence on the health benefits of intermittent fasting, and discuss physiological mechanisms by which intermittent fasting might lead to improved health outcomes. A MEDLINE search was performed using PubMed and the terms "intermittent fasting," "fasting," "time-restricted feeding," and "food timing." Modified fasting regimens appear to promote weight loss and may improve metabolic health. Several lines of evidence also support the hypothesis that eating patterns that reduce or eliminate nighttime eating and prolong nightly fasting intervals may result in sustained improvements in human health. Intermittent fasting regimens are hypothesized to influence metabolic regulation via effects on (a) circadian biology, (b) the gut microbiome, and (c) modifiable lifestyle behaviors, such as sleep. If proven to be efficacious, these eating regimens offer promising nonpharmacological approaches to improving health at the population level, with multiple public health benefits.

  3. FBCT fast intensity measurement using TRIC cards

    CERN Document Server

    Allica, J C; Belohrad, D; Jensen, L; Lenardon, F; SØby, L

    2015-01-01

    At the CERN PS complex, precise fast intensity measurements are very important in order to optimize the transfer efficiencies between the different accelerators. Over the last two years a complete renovation has been ongoing, where the old electronics, based on analogue integrators, have been replaced by a fully digital system enclosed in a single VME based card. This new system called TRIC (Transformer Integration Card) is based on a 12 bit, 212 MS/s ADC and an FPGA for the signal processing. Also located on the same board one finds a 250 V/1.5 W DCDC converter used to generate precise calibration pulses.

  4. Fast track-hoftealloplastik

    DEFF Research Database (Denmark)

    Hansen, Torben Bæk; Gromov, Kirill; Kristensen, Billy B

    2017-01-01

    Fast-track surgery implies a coordinated perioperative approach aimed at reducing surgical stress and facilitating post-operative recovery. The fast-track programme has reduced post-operative length of stay and has led to shorter convalescence with more rapid functional recovery and decreased...... morbidity and mortality in total hip arthroplasty. It should now be a standard total hip arthroplasty patient pathway, but fine tuning of the multiple factors in the fast-track pathway is still needed in patients with special needs or high comorbidity burden....

  5. Fast Flux Watch: A mechanism for online detection of fast flux networks

    Directory of Open Access Journals (Sweden)

    Basheer N. Al-Duwairi

    2014-07-01

    Full Text Available Fast flux networks represent a special type of botnets that are used to provide highly available web services to a backend server, which usually hosts malicious content. Detection of fast flux networks continues to be a challenging issue because of the similar behavior between these networks and other legitimate infrastructures, such as CDNs and server farms. This paper proposes Fast Flux Watch (FF-Watch, a mechanism for online detection of fast flux agents. FF-Watch is envisioned to exist as a software agent at leaf routers that connect stub networks to the Internet. The core mechanism of FF-Watch is based on the inherent feature of fast flux networks: flux agents within stub networks take the role of relaying client requests to point-of-sale websites of spam campaigns. The main idea of FF-Watch is to correlate incoming TCP connection requests to flux agents within a stub network with outgoing TCP connection requests from the same agents to the point-of-sale website. Theoretical and traffic trace driven analysis shows that the proposed mechanism can be utilized to efficiently detect fast flux agents within a stub network.

  6. Single-step colloidal quantum dot films for infrared solar harvesting

    KAUST Repository

    Kiani, Amirreza; Sutherland, Brandon R.; Kim, Younghoon; Ouellette, Olivier; Levina, Larissa; Walters, Grant; Dinh, Cao Thang; Liu, Mengxia; Voznyy, Oleksandr; Lan, Xinzheng; Labelle, Andre J.; Ip, Alexander H.; Proppe, Andrew; Ahmed, Ghada H.; Mohammed, Omar F.; Hoogland, Sjoerd; Sargent, Edward H.

    2016-01-01

    . To date, IR CQD solar cells have been made using a wasteful and complex sequential layer-by-layer process. Here, we demonstrate ∼1 eV bandgap solar-harvesting CQD films deposited in a single step. By engineering a fast-drying solvent mixture for metal

  7. Fast ultrasonic visualisation under sodium. Application to the fast neutron reactors

    International Nuclear Information System (INIS)

    Imbert, Ch.

    1997-01-01

    The fast ultrasonic visualization under sodium is in the programme of research and development on the inspection inside the fast neutron reactors. This work is about the development of a such system of fast ultrasonic imaging under sodium, in order to improve the existing visualization systems. This system is based on the principle of orthogonal imaging, it uses two linear antennas with an important dephasing having 128 piezo-composite elements of central frequency equal to 1.6 MHz. (N.C.)

  8. High-resolution(18)F-fluorodeoxyglucose positron emission tomography and magnetic resonance imaging for pituitary adenoma detection in Cushing disease.

    Science.gov (United States)

    Chittiboina, Prashant; Montgomery, Blake K; Millo, Corina; Herscovitch, Peter; Lonser, Russell R

    2015-04-01

    OBJECT High-resolution PET (hrPET) performed using a high-resolution research tomograph is reported as having a resolution of 2 mm and could be used to detect corticotroph adenomas through uptake of(18)F-fluorodeoxyglucose ((18)F-FDG). To determine the sensitivity of this imaging modality, the authors compared(18)F-FDG hrPET and MRI detection of pituitary adenomas in Cushing disease (CD). METHODS Consecutive patients with CD who underwent preoperative(18)F-FDG hrPET and MRI (spin echo [SE] and spoiled gradient recalled [SPGR] sequences) were prospectively analyzed. Standardized uptake values (SUVs) were calculated from hrPET and were compared with MRI findings. Imaging findings were correlated to operative and histological findings. RESULTS Ten patients (7 females and 3 males) were included (mean age 30.8 ± 19.3 years; range 11-59 years). MRI revealed a pituitary adenoma in 4 patients (40% of patients) on SE and 7 patients (70%) on SPGR sequences.(18)F-FDG hrPET demonstrated increased(18)F-FDG uptake consistent with an adenoma in 4 patients (40%; adenoma size range 3-14 mm). Maximum SUV was significantly higher for(18)F-FDG hrPET-positive tumors (difference = 5.1, 95% CI 2.1-8.1; p = 0.004) than for(18)F-FDG hrPET-negative tumors.(18)F-FDG hrPET positivity was not associated with tumor volume (p = 0.2) or dural invasion (p = 0.5). Midnight and morning ACTH levels were associated with(18)F-FDG hrPET positivity (p = 0.01 and 0.04, respectively) and correlated with the maximum SUV (R = 0.9; p = 0.001) and average SUV (R = 0.8; p = 0.01). All(18)F-FDG hrPET-positive adenomas had a less than a 180% ACTH increase and(18)F-FDG hrPET-negative adenomas had a greater than 180% ACTH increase after CRH stimulation (p = 0.03). Three adenomas were detected on SPGR MRI sequences that were not detected by(18)F-FDG hrPET imaging. Two adenomas not detected on SE (but no adenomas not detected on SPGR) were detected on(18)F-FDG hrPET. CONCLUSIONS While(18)F-FDG hrPET imaging can

  9. The TORE SUPRA fast reciprocating RF probe

    International Nuclear Information System (INIS)

    Thomas, C.E. Jr.; Harris, J.H.; Haste, G.R.

    1994-01-01

    A fast reciprocating ICRF (Ion Cyclotron Range of Frequencies) probe was installed and operated on TORE SUPRA during 1992/1993. The body of the probe was originally used on the ATF experiment at ORNL. The probe was adapted for use on TORE SUPRA, and mounted on one of the two fast reciprocating probe mounts. The probe consists of two orthogonal single-turn wire loops, mounted so that one loop senses toroidal RF magnetic fields and the other senses poloidal RF magnetic fields. The probe began operation in June, 1993. The probe active area is approximately 5 cm long by 2 cm, and the reciprocating mount has a slow stroke (5 cm/sec) of 30 cm by 2 cm, and the reciprocating mount has a slow stroke (5 cm/sec) of 30 cm and a fast stroke (1.5 m/sec) of about 10 cm. The probe was operated at distances from the plasma edge ranging from 30 cm to -5 cm (i.e., inside the last closed flux surface). The probe design, electronics, calibration, data acquisition and data processing are discussed. First data from the probe are presented as a function of ICRF power, distance from the plasma, loop orientation, and other plasma parameters. Initial data shows parametric instabilities do not play an important role for ICRF in the TORE SUPRA edge and scrape-off-layer (SOL) plasmas. Additionally it is observed that the probe signal has little or no dependence on position in the SOL/plasma edge

  10. Study of the fast inversion recovery pulse sequence. With reference to fast fluid attenuated inversion recovery and fast short TI inversion recovery pulse sequence

    International Nuclear Information System (INIS)

    Tsuchihashi, Toshio; Maki, Toshio; Suzuki, Takeshi

    1997-01-01

    The fast inversion recovery (fast IR) pulse sequence was evaluated. We compared the fast fluid attenuated inversion recovery (fast FLAIR) pulse sequence in which inversion time (TI) was established as equal to the water null point for the purpose of the water-suppressed T 2 -weighted image, with the fast short TI inversion recovery (fast STIR) pulse sequence in which TI was established as equal to the fat null point for purpose of fat suppression. In the fast FLAIR pulse sequence, the water null point was increased by making TR longer. In the FLAIR pulse sequence, the longitudinal magnetization contrast is determined by TI. If TI is increased, T 2 -weighted contrast improves in the same way as increasing TR for the SE pulse sequence. Therefore, images should be taken with long TR and long TI, which are longer than TR and longer than the water null point. On the other hand, the fat null point is not affected by TR in the fast STIR pulse sequence. However, effective TE was affected by variation of the null point. This increased in proportion to the increase in effective TE. Our evaluation indicated that the fast STIR pulse sequence can control the extensive signals from fat in a short time. (author)

  11. Fast breeder reactors

    International Nuclear Information System (INIS)

    Waltar, A.E.; Reynolds, A.B.

    1981-01-01

    This book describes the major design features of fast breeder reactors and the methods used for their design and analysis. The foremost objective of this book is to fulfill the need for a textbook on Fast Breeder Reactor (FBR) technology at the graduate level or the advanced undergraduate level. It is assumed that the reader has an introductory understanding of reactor theory, heat transfer, and fluid mechanics. The book is expected to be used most widely for a one-semester general course on fast breeder reactors, with the extent of material covered to vary according to the interest of the instructor. The book could also be used effectively for a two-quarter or a two-semester course. In addition, the book could serve as a text for a course on fast reactor safety since many topics other than those appearing in the safety chapters relate to FBR safety. Methodology in fast reactor design and analysis, together with physical descriptions of systems, is emphasized in this text more than numerical results. Analytical and design results continue to change with the ongoing evolution of FBR design whereas many design methods have remained fundamentally unchanged for a considerable time

  12. Superacid univalent metal phosphites (MH2PO3)2·H3PO3 (M Rb, Tl+) and MH2PO3·H3PO3 (M = K, Cs): synthesis and structure

    International Nuclear Information System (INIS)

    Kosterina, E.V.; Troyanov, S.I.; Aslanov, L.A.; Kemnits, Eh.

    2001-01-01

    Crystal superacid phosphites α-CsH 2 PO 3 ·H 3 PO 3 (1) and β-CsH 2 PO 3 ·H 3 PO 3 (2) were prepared by means of interaction between cesium carbonate and phosphoric acid excess. The structure of the compounds, i.e.: 1-rhombic crystal system, sp.gr. P2 1 2 1 2 1 , a = 6.033 (1), b = 6.444 (1), c = 18.345 (4) A: 2-monoclinic crystal system, sp.gr. C2/c, a = 9.990 (3), b = 12.197 (4), c = 6.866 (2) A, β = 118.14 (3) deg, was determined by the method of X-ray diffraction analysis of monocrystals at 150 K. Comparative analysis of the crystal structure and hydrogen bond systems in acid phosphites of different composition was conducted [ru

  13. Study on beam geometry and image reconstruction algorithm in fast neutron computerized tomography at NECTAR facility

    Science.gov (United States)

    Guo, J.; Bücherl, T.; Zou, Y.; Guo, Z.

    2011-09-01

    Investigations on the fast neutron beam geometry for the NECTAR facility are presented. The results of MCNP simulations and experimental measurements of the beam distributions at NECTAR are compared. Boltzmann functions are used to describe the beam profile in the detection plane assuming the area source to be set up of large number of single neutron point sources. An iterative algebraic reconstruction algorithm is developed, realized and verified by both simulated and measured projection data. The feasibility for improved reconstruction in fast neutron computerized tomography at the NECTAR facility is demonstrated.

  14. Study on beam geometry and image reconstruction algorithm in fast neutron computerized tomography at NECTAR facility

    International Nuclear Information System (INIS)

    Guo, J.; Buecherl, T.; Zou, Y.; Guo, Z.

    2011-01-01

    Investigations on the fast neutron beam geometry for the NECTAR facility are presented. The results of MCNP simulations and experimental measurements of the beam distributions at NECTAR are compared. Boltzmann functions are used to describe the beam profile in the detection plane assuming the area source to be set up of large number of single neutron point sources. An iterative algebraic reconstruction algorithm is developed, realized and verified by both simulated and measured projection data. The feasibility for improved reconstruction in fast neutron computerized tomography at the NECTAR facility is demonstrated.

  15. Study on beam geometry and image reconstruction algorithm in fast neutron computerized tomography at NECTAR facility

    Energy Technology Data Exchange (ETDEWEB)

    Guo, J. [State Key Laboratory of Nuclear Physics and Technology and School of Physics, Peking University, 5 Yiheyuan Lu, Beijing 100871 (China); Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, Garching 80748 (Germany); Buecherl, T. [Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, Garching 80748 (Germany); Zou, Y., E-mail: zouyubin@pku.edu.cn [State Key Laboratory of Nuclear Physics and Technology and School of Physics, Peking University, 5 Yiheyuan Lu, Beijing 100871 (China); Guo, Z. [State Key Laboratory of Nuclear Physics and Technology and School of Physics, Peking University, 5 Yiheyuan Lu, Beijing 100871 (China)

    2011-09-21

    Investigations on the fast neutron beam geometry for the NECTAR facility are presented. The results of MCNP simulations and experimental measurements of the beam distributions at NECTAR are compared. Boltzmann functions are used to describe the beam profile in the detection plane assuming the area source to be set up of large number of single neutron point sources. An iterative algebraic reconstruction algorithm is developed, realized and verified by both simulated and measured projection data. The feasibility for improved reconstruction in fast neutron computerized tomography at the NECTAR facility is demonstrated.

  16. Fast neutrons dosimetry

    International Nuclear Information System (INIS)

    Rzyski, B.M.

    1977-01-01

    A proton recoil technique has been developed for inducing thermoluminescence with incident fast neutrons. CaF 2 was used as the TL phosphor, and cane sugar and polyethylene were used as proton radiators. The phosphor and the hydrogeneous material powders were well mixed, encapsulated in glass tubes and exposed to Am-Be sources, resulting in recoils from incident fast neutrons of energy between 0,25 and 11,25 MeV. The intrinsic response of pure CaF 2 to fast neutrons without a hydrogeneous radiator was checked by using LiF (TLD-700). Glow curves were recorded from room temperature up to 350 0 C after different doses of neutrons and gamma rays of 60 Co. First collision dose due to fast neutrons in tissue like materials such as cane sugar and polyethylene was also calculated [pt

  17. Examining the causal association of fasting glucose with blood pressure in healthy children and adolescents

    DEFF Research Database (Denmark)

    Goharian, T S; Andersen, Lars Bo; Franks, P W

    2015-01-01

    The aim of the study was to determine whether genetically raised fasting glucose (FG) levels are associated with blood pressure (BP) in healthy children and adolescents. We used 11 common genetic variants of FG discovered in genome-wide association studies (GWAS), including the rs560887 single...

  18. Power deposition by neutral beam injected fast ions in field-reversed configurations

    International Nuclear Information System (INIS)

    Takahashi, Toshiki; Kato, Takayuki; Kondoh, Yoshiomi; Iwasaka, Naotaka

    2004-04-01

    Effects of Coulomb collisions on neutral beam (NB) injected fast ions into Field-Reversed Configuration (FRC) plasmas are investigated by calculating the single particle orbits, where the ions are subject to the slowing down and pitch angle collisions. The Monte-Carlo method is used for the pitch angle scattering, and the friction term is added to the equation of motion to show effects of slowing down collision such as the deposited power profile. Calculation parameters used are relevant to the NB injection on the FRC Injection Experiment (FIX) device. It is found that the dominant local power deposition occurs in the open field region between the X-point and the mirror point because of a concentration of fast ions and a longer duration travel at the mirror reflection point. In the present calculation, the maximum deposited power to the FRC plasma is about 10% of the injected power. Although the pitch angle scattering by Coulomb collision destroys the mirror confinement of NB injected fast ions, this effect is found negligible. The loss mechanism due to non-adiabatic fast ion motion, which is intrinsic in non-uniform FRC plasmas, affects much greater than the pitch angle scattering by Coulomb collision. (author)

  19. Fasting and Urinary Stones

    Directory of Open Access Journals (Sweden)

    Ali Shamsa

    2013-11-01

    Full Text Available Introduction: Fasting is considered as one of the most important practices of Islam, and according to Prophet Mohammad, fasting is obligatory upon Muslims. The aim of this study is to evaluate the effects of fasting on urinary stones. Materials and Methods: Very few studies have been carried out on urinary stones and the effect of Ramadan fasting. The sources of the present study are Medline and articles presented by local and Muslim researchers. Meanwhile, since we are acquainted with three well-known researchers in the field of urology, we contacted them via email and asked for their professional opinions. Results: The results of studies about the relationship of urinary stones and their incidence in Ramadan are not alike, and are even sometimes contradictory. Some believe that increased incidence of urinary stones in Ramadan is related not to fasting, but to the rise of weather temperature in hot months, and an increase in humidity. Conclusion: Numerous biological and behavioral changes occur in people who fast in Ramadan and some researchers believe that urinary stone increases during this month.

  20. Single-footprint retrievals for AIRS using a fast TwoSlab cloud-representation model and the SARTA all-sky infrared radiative transfer algorithm

    Science.gov (United States)

    DeSouza-Machado, Sergio; Larrabee Strow, L.; Tangborn, Andrew; Huang, Xianglei; Chen, Xiuhong; Liu, Xu; Wu, Wan; Yang, Qiguang

    2018-01-01

    One-dimensional variational retrievals of temperature and moisture fields from hyperspectral infrared (IR) satellite sounders use cloud-cleared radiances (CCRs) as their observation. These derived observations allow the use of clear-sky-only radiative transfer in the inversion for geophysical variables but at reduced spatial resolution compared to the native sounder observations. Cloud clearing can introduce various errors, although scenes with large errors can be identified and ignored. Information content studies show that, when using multilayer cloud liquid and ice profiles in infrared hyperspectral radiative transfer codes, there are typically only 2-4 degrees of freedom (DOFs) of cloud signal. This implies a simplified cloud representation is sufficient for some applications which need accurate radiative transfer. Here we describe a single-footprint retrieval approach for clear and cloudy conditions, which uses the thermodynamic and cloud fields from numerical weather prediction (NWP) models as a first guess, together with a simple cloud-representation model coupled to a fast scattering radiative transfer algorithm (RTA). The NWP model thermodynamic and cloud profiles are first co-located to the observations, after which the N-level cloud profiles are converted to two slab clouds (TwoSlab; typically one for ice and one for water clouds). From these, one run of our fast cloud-representation model allows an improvement of the a priori cloud state by comparing the observed and model-simulated radiances in the thermal window channels. The retrieval yield is over 90 %, while the degrees of freedom correlate with the observed window channel brightness temperature (BT) which itself depends on the cloud optical depth. The cloud-representation and scattering package is benchmarked against radiances computed using a maximum random overlap (RMO) cloud scheme. All-sky infrared radiances measured by NASA's Atmospheric Infrared Sounder (AIRS) and NWP thermodynamic and cloud

  1. Single-footprint retrievals for AIRS using a fast TwoSlab cloud-representation model and the SARTA all-sky infrared radiative transfer algorithm

    Directory of Open Access Journals (Sweden)

    S. DeSouza-Machado

    2018-01-01

    Full Text Available One-dimensional variational retrievals of temperature and moisture fields from hyperspectral infrared (IR satellite sounders use cloud-cleared radiances (CCRs as their observation. These derived observations allow the use of clear-sky-only radiative transfer in the inversion for geophysical variables but at reduced spatial resolution compared to the native sounder observations. Cloud clearing can introduce various errors, although scenes with large errors can be identified and ignored. Information content studies show that, when using multilayer cloud liquid and ice profiles in infrared hyperspectral radiative transfer codes, there are typically only 2–4 degrees of freedom (DOFs of cloud signal. This implies a simplified cloud representation is sufficient for some applications which need accurate radiative transfer. Here we describe a single-footprint retrieval approach for clear and cloudy conditions, which uses the thermodynamic and cloud fields from numerical weather prediction (NWP models as a first guess, together with a simple cloud-representation model coupled to a fast scattering radiative transfer algorithm (RTA. The NWP model thermodynamic and cloud profiles are first co-located to the observations, after which the N-level cloud profiles are converted to two slab clouds (TwoSlab; typically one for ice and one for water clouds. From these, one run of our fast cloud-representation model allows an improvement of the a priori cloud state by comparing the observed and model-simulated radiances in the thermal window channels. The retrieval yield is over 90 %, while the degrees of freedom correlate with the observed window channel brightness temperature (BT which itself depends on the cloud optical depth. The cloud-representation and scattering package is benchmarked against radiances computed using a maximum random overlap (RMO cloud scheme. All-sky infrared radiances measured by NASA's Atmospheric Infrared Sounder (AIRS and NWP

  2. A review of fast reactor program in Japan

    International Nuclear Information System (INIS)

    Matsuno, Y.

    1982-01-01

    The fast breeder reactor development project in Japan has been in progress for the past twelve months and will be continued this fiscal year, from April 1982 through March 1983, at a similar scale of effort both in budget and personnel to those of the fiscal year of 1981. The 1982 year budget for R and D work and for construction of a prototype fast breeder reactor MONJU is approximately 20 and 27 billion yen respectively, excluding wages for the personnel of the Power Reactor and Nuclear Fuel Development Corporation, PNC. The number of the technical people currently engaged in the fast breeder reactor development in the PNC is approximately 530, excluding those working for plutonium fuel fabrication. Concerning the experimental fast reactor JOYO, power increase from 50 MWt to 75 MWt was made in July 1979 and six operational cycles at 75 MWt were completed in December 1981. With respect to the prototype reactor MONJU, progress toward construction has been made and an environmental impact statement of the reactor was approved by the authorities concerned, and the licensing of the first step was completed at the end of 1981. Preliminary design studies of a large LMFBR are being made by PNC and also by utilities. A design study being conducted by PNC is on a 1000 MWe plant of loop type by extrapolating the technology to be developed by the time of commissioning of MONJU. A group of utilities is conducting a similar study, but covering somewhat wider range of parameters and options of design. Close contact between the group and PNC has been kept. In the future, those design efforts will be combined as a single design effort, when a major effort for developing a large demonstration reactor will be initiated at around the commencement of construction of the prototype reactor MONJU

  3. Fast reactors in nuclear power

    Energy Technology Data Exchange (ETDEWEB)

    Kazachkovskii, O

    1981-02-01

    The possible applications are discussed of fast reactor nuclear power plants. Basic differences are explained in fast and thermal reactors, mainly with a view to nuclear fuel utilization. Discussed in more detail are the problems of nuclear fuel reproduction and the nost important technical problems of fast reactors. Flow charts are shown of heat transfer for fast reactors BN-350 (loop design) and BN-600 (integral coolant circuit design). Main specifications are given for demonstration and power fast reactors in operation, under construction and in project-stage.

  4. TRACKING TESTS FOR THE SNS FAST INJECTION BUMP POWER SUPPLY

    International Nuclear Information System (INIS)

    ENG, W.; CUTLER, R.; DEWAN, S.

    2004-01-01

    The tracking requirement of the SNS Fast Injection Bump power supplies is described. In addition to the usual tracking between the load current and the input reference of a power supply, these power supplies must also track between pairs of units under slightly different loads. This paper describes the use of a current-null test to measure tracking performances. For the actual tests, a single dummy magnet load was used to measure the tracking between the first two production units at the manufacturer's facility. Using the Yokogawa WE7000 waveform. PC-based measurement instrument, input and output waveforms are digitized and stored in data files. A program written for this application is then used to extract data from these files to construct, analyze the waveforms and characterize the power supply performance. Results of the measurements of two SNS Fast Injection Bump power supplies will be presented in this paper

  5. FastMag: Fast micromagnetic simulator for complex magnetic structures (invited)

    Science.gov (United States)

    Chang, R.; Li, S.; Lubarda, M. V.; Livshitz, B.; Lomakin, V.

    2011-04-01

    A fast micromagnetic simulator (FastMag) for general problems is presented. FastMag solves the Landau-Lifshitz-Gilbert equation and can handle multiscale problems with a high computational efficiency. The simulator derives its high performance from efficient methods for evaluating the effective field and from implementations on massively parallel graphics processing unit (GPU) architectures. FastMag discretizes the computational domain into tetrahedral elements and therefore is highly flexible for general problems. The magnetostatic field is computed via the superposition principle for both volume and surface parts of the computational domain. This is accomplished by implementing efficient quadrature rules and analytical integration for overlapping elements in which the integral kernel is singular. Thus, discretized superposition integrals are computed using a nonuniform grid interpolation method, which evaluates the field from N sources at N collocated observers in O(N) operations. This approach allows handling objects of arbitrary shape, allows easily calculating of the field outside the magnetized domains, does not require solving a linear system of equations, and requires little memory. FastMag is implemented on GPUs with ?> GPU-central processing unit speed-ups of 2 orders of magnitude. Simulations are shown of a large array of magnetic dots and a recording head fully discretized down to the exchange length, with over a hundred million tetrahedral elements on an inexpensive desktop computer.

  6. Electron correlations in single-electron capture from helium by fast protons and α particles

    International Nuclear Information System (INIS)

    Mancev, Ivan; Milojevic, Nenad

    2010-01-01

    Single-electron capture from heliumlike atomic systems by bare projectiles is investigated by means of the four-body boundary-corrected first Born approximation (CB1-4B). The effect of the dynamic electron correlation is explicitly taken into account through the complete perturbation potential. The quantum-mechanical post and prior transition amplitudes for single charge exchange encompassing symmetric and/or asymmetric collisions are derived in terms of two-dimensional real integrals in the case of the prior form and five-dimensional quadratures for the post form. An illustrative computation is performed for single-electron capture from helium by protons and α particles at intermediate and high impact energies. The role of dynamic correlations is examined as a function of increased projectile energy. The validity and utility of the proposed CB1-4B method is critically assessed in comparison with the existing experimental data for total cross sections, and excellent agreement is obtained.

  7. Sistem Gesture Accelerometer dengan Metode Fast Dynamic Time Warping (FastDTW

    Directory of Open Access Journals (Sweden)

    Sam Farisa Chaerul Haviana

    2016-01-01

    Full Text Available In the modern environment, the interaction between humans and computers require a more natural form of interaction. Therefore, it is important to be able to build a system that can meet these demands, such as by building a hand gesture recognition system or gesture to create a more natural form of interaction. This study aims to design a smartphone’s accelerometer gesture system as human computer interaction interfaces using FastDTW (Fast Dynamic Time Warping.The result of this study is form of gesture interaction which implemented in a system that can make the process of recognition of the human hand movements based on a smartphone accelerometer which generates a command to run the media player application functions as a case study. FastDTW as the development of Dynamic Time Warping method (DTW is able to compute faster than DTW and have an accuracy approaching DTW. From the test results, FastDTW show a fairly high degree of accuracy reached 86% and showed a better computing speed compared to DTW   Keywords: Human and Computer Interaction, Accelerometer-based gesture, FastDTW, Media player application function

  8. Fast spine echo and fast fluid attenuated inversion recovery sequences in multiple sclerosis

    International Nuclear Information System (INIS)

    Paolillo, Andrea; Giugni, Elisabetta; Bozzao, Alessandro; Bastianello, Stefano

    1997-01-01

    Fast spin echo (FSE) and fast fluid attenuated inversion recovery (fast-FLAIR) sequences, were compared with conventional spin echo (CSE) in quantitating multiple sclerosis (MS) lesion burden. For each sequence, the total number and volume of MS lesions were calculated in 38 remitting multiple sclerosis patients using a semiautomated lesion detection program. Conventional spin echo, fast spin echo, and fast fluid attenuated inversion recovery image were reported on randomly and at different times by two expert observers. Interobserver differences, the time needed to quantitative multiple sclerosis lesions and lesion signal intensity (contrast-to-noise ratio and overall contrast) were considered. The lesions were classified by site into infratentorial, white matter and cortical/subcortical. A total of 2970 lesions with a volume of 961.7 cm 3 was calculated on conventional spin echo images. Fast spin echo images depicted fewer (16.6%; p < .005) and smaller (24.9%; p < .0001) lesions and the differences were statistically significant. Despite an overall nonsignificant reduction for fast-FLAIR images (-5% and 4.8% for lesion number and volume, respectively), significantly lower values (lesion number: p < 0.1; volume: p < .04)were observed for infratentorial lesions, while significantly higher values were seen for cortical/subcortical lesions (lesion number: p < .01; volume: p < .02). A higher lesion/white matter contrast (p < .002), a significant time saving for lesion burden quantitation (p < .05) and very low interobserver variability were found in favor of fast-FLAIR. Our data suggest that, despite the limitations regarding infratentorial lesions, fast-FLAIR sequences are indicated in R studies because of their good identification of cortical/subcortical lesions, almost complete interobserver agreement, higher contrast-to-noise ratio and limited time needed for semiautomated quantitation

  9. A fast PID controller Design for Modern PLC for Process Control Application

    International Nuclear Information System (INIS)

    Mirza, A.; Nafis, A.; Anees, R.M.; Idris, S.

    2004-01-01

    PID is the most widely used control scheme in the process industry. Pill controllers are utilized for the control of such varied parameters as pressure, flow, temperature, etc. One characteristic of these parameters is that they posses slow dynamics. Most of the available digital controllers can manipulate only a single parameter- multiple controllers are required for control of more than one parameter. The Fast PID Controller for Modem PLC (Programmable Logic Controller) developed by the authors, provides control of several parameters at a time (through a single Pill control element), enhanced programmability including variable sampling period, parameter monitoring and data storage, which may be easily implemented in a PLC. (author)

  10. TORE SUPRA fast reciprocating radio frequency probe (abstract)

    International Nuclear Information System (INIS)

    Thomas, C.E. Jr.; Harris, J.H.; Haste, G.R.; Kwon, M.; Goulding, R.H.; Hoffman, D.J.; Saoutic, B.; Becoulet, A.; Fraboulet, D.; Beaumont, B.; Kuus, H.; Ladurelle, L.; Pascal, J.Y.

    1995-01-01

    A fast reciprocating ion cyclotron range of frequencies (ICRF) probe was installed and operated on TORE SUPRA during 1992/1993. The body of the probe was originally used on the ATF experiment at Oak Ridge National Laboratory. The probe was adapted for use on TORE SUPRA, and mounted on one of the two fast reciprocating probe mounts. The probe consists of two orthogonal single-turn wire loops, mounted so that one loop senses toroidal rf magnetic fields and the other senses poloidal rf magnetic fields. The probe began operation in June, 1993. The probe active area is approximately 5 cm long by 2 cm, and the reciprocating mount has a slow stroke (5 cm/s) of 30 cm and a fast stroke (1.5 m/s) of about 10 cm. The probe was operated at distances from the plasma edge ranging from 30 to -5 cm (i.e., inside the last closed flux surface). The probe design, electronics, calibration, data acquisition, and data processing are discussed. First data from the probe are presented as a function of ICRF power, distance from the plasma, loop orientation, and other plasma parameters. Initial data show parametric instabilities do not play an important role for ICRF in the TORE SUPRA edge and scrape-off-layer (SOL) plasmas. Additionally it is observed that the probe signal has little or no dependence on position in the SOL/plasma edge

  11. Transcription factor assisted loading and enhancer dynamics dictate the hepatic fasting response

    Science.gov (United States)

    Goldstein, Ido; Baek, Songjoon; Presman, Diego M.; Paakinaho, Ville; Swinstead, Erin E.; Hager, Gordon L.

    2017-01-01

    Fasting elicits transcriptional programs in hepatocytes leading to glucose and ketone production. This transcriptional program is regulated by many transcription factors (TFs). To understand how this complex network regulates the metabolic response to fasting, we aimed at isolating the enhancers and TFs dictating it. Measuring chromatin accessibility revealed that fasting massively reorganizes liver chromatin, exposing numerous fasting-induced enhancers. By utilizing computational methods in combination with dissecting enhancer features and TF cistromes, we implicated four key TFs regulating the fasting response: glucocorticoid receptor (GR), cAMP responsive element binding protein 1 (CREB1), peroxisome proliferator activated receptor alpha (PPARA), and CCAAT/enhancer binding protein beta (CEBPB). These TFs regulate fuel production by two distinctly operating modules, each controlling a separate metabolic pathway. The gluconeogenic module operates through assisted loading, whereby GR doubles the number of sites occupied by CREB1 as well as enhances CREB1 binding intensity and increases accessibility of CREB1 binding sites. Importantly, this GR-assisted CREB1 binding was enhancer-selective and did not affect all CREB1-bound enhancers. Single-molecule tracking revealed that GR increases the number and DNA residence time of a portion of chromatin-bound CREB1 molecules. These events collectively result in rapid synergistic gene expression and higher hepatic glucose production. Conversely, the ketogenic module operates via a GR-induced TF cascade, whereby PPARA levels are increased following GR activation, facilitating gradual enhancer maturation next to PPARA target genes and delayed ketogenic gene expression. Our findings reveal a complex network of enhancers and TFs that dynamically cooperate to restore homeostasis upon fasting. PMID:28031249

  12. Determination of Cross-Sections of Fast-Muon-Induced Reactions to Cosmogenic Radionuclides

    CERN Multimedia

    Hagner, T; Heisinger, B; Niedermayer, M; Nolte, E; Oberauer, L; Schonert, S; Kubik, P W

    2002-01-01

    %NA54 %title\\\\ \\\\We propose to measure cross-sections for fast muon-induced production of radionuclides. Firstly to study the contribution of fast-muon-induced reactions to the in-situ production of cosmogenic radionuclides in the lithosphere. Concrete is used to simulate the rock and to generate a secondary particle shower. The reaction channels to be measured are: C to $^{10}$Be, O to $^{10}$Be and $^{14}$C, Si to $^{26}$Al, S to $^{26}$Al, Ca to $^{36}$Cl, Fe to $^{53}$Mn and $^{205}$Tl to $^{205}$Pb. The energy dependent cross-section can be described by one single parameter $\\sigma_0$ and the energy dependence $\\rm\\overline{E}^{0.7}$ on the mean energy $\\rm\\overline{E}$. The irradiations of the targets is done at CERN. The produced radionuclides are measured by accelerator mass spectrometry in Munich and Zurich.\\\\ \\\\Secondly, muon induced signals can be a major source of background in experiments with low event rates located deep underground. We intent to study the produced radioactivity by fast-muon-ind...

  13. Fast food purchasing and access to fast food restaurants: a multilevel analysis of VicLANES

    Science.gov (United States)

    Thornton, Lukar E; Bentley, Rebecca J; Kavanagh, Anne M

    2009-01-01

    Background While previous research on fast food access and purchasing has not found evidence of an association, these studies have had methodological problems including aggregation error, lack of specificity between the exposures and outcomes, and lack of adjustment for potential confounding. In this paper we attempt to address these methodological problems using data from the Victorian Lifestyle and Neighbourhood Environments Study (VicLANES) – a cross-sectional multilevel study conducted within metropolitan Melbourne, Australia in 2003. Methods The VicLANES data used in this analysis included 2547 participants from 49 census collector districts in metropolitan Melbourne, Australia. The outcome of interest was the total frequency of fast food purchased for consumption at home within the previous month (never, monthly and weekly) from five major fast food chains (Red Rooster, McDonalds, Kentucky Fried Chicken, Hungry Jacks and Pizza Hut). Three measures of fast food access were created: density and variety, defined as the number of fast food restaurants and the number of different fast food chains within 3 kilometres of road network distance respectively, and proximity defined as the road network distance to the closest fast food restaurant. Multilevel multinomial models were used to estimate the associations between fast food restaurant access and purchasing with never purchased as the reference category. Models were adjusted for confounders including determinants of demand (attitudes and tastes that influence food purchasing decisions) as well as individual and area socio-economic characteristics. Results Purchasing fast food on a monthly basis was related to the variety of fast food restaurants (odds ratio 1.13; 95% confidence interval 1.02 – 1.25) after adjusting for individual and area characteristics. Density and proximity were not found to be significant predictors of fast food purchasing after adjustment for individual socio-economic predictors

  14. Fast food purchasing and access to fast food restaurants: a multilevel analysis of VicLANES.

    Science.gov (United States)

    Thornton, Lukar E; Bentley, Rebecca J; Kavanagh, Anne M

    2009-05-27

    While previous research on fast food access and purchasing has not found evidence of an association, these studies have had methodological problems including aggregation error, lack of specificity between the exposures and outcomes, and lack of adjustment for potential confounding. In this paper we attempt to address these methodological problems using data from the Victorian Lifestyle and Neighbourhood Environments Study (VicLANES) - a cross-sectional multilevel study conducted within metropolitan Melbourne, Australia in 2003. The VicLANES data used in this analysis included 2547 participants from 49 census collector districts in metropolitan Melbourne, Australia. The outcome of interest was the total frequency of fast food purchased for consumption at home within the previous month (never, monthly and weekly) from five major fast food chains (Red Rooster, McDonalds, Kentucky Fried Chicken, Hungry Jacks and Pizza Hut). Three measures of fast food access were created: density and variety, defined as the number of fast food restaurants and the number of different fast food chains within 3 kilometres of road network distance respectively, and proximity defined as the road network distance to the closest fast food restaurant.Multilevel multinomial models were used to estimate the associations between fast food restaurant access and purchasing with never purchased as the reference category. Models were adjusted for confounders including determinants of demand (attitudes and tastes that influence food purchasing decisions) as well as individual and area socio-economic characteristics. Purchasing fast food on a monthly basis was related to the variety of fast food restaurants (odds ratio 1.13; 95% confidence interval 1.02 - 1.25) after adjusting for individual and area characteristics. Density and proximity were not found to be significant predictors of fast food purchasing after adjustment for individual socio-economic predictors. Although we found an independent

  15. Fast food purchasing and access to fast food restaurants: a multilevel analysis of VicLANES

    Directory of Open Access Journals (Sweden)

    Kavanagh Anne M

    2009-05-01

    Full Text Available Abstract Background While previous research on fast food access and purchasing has not found evidence of an association, these studies have had methodological problems including aggregation error, lack of specificity between the exposures and outcomes, and lack of adjustment for potential confounding. In this paper we attempt to address these methodological problems using data from the Victorian Lifestyle and Neighbourhood Environments Study (VicLANES – a cross-sectional multilevel study conducted within metropolitan Melbourne, Australia in 2003. Methods The VicLANES data used in this analysis included 2547 participants from 49 census collector districts in metropolitan Melbourne, Australia. The outcome of interest was the total frequency of fast food purchased for consumption at home within the previous month (never, monthly and weekly from five major fast food chains (Red Rooster, McDonalds, Kentucky Fried Chicken, Hungry Jacks and Pizza Hut. Three measures of fast food access were created: density and variety, defined as the number of fast food restaurants and the number of different fast food chains within 3 kilometres of road network distance respectively, and proximity defined as the road network distance to the closest fast food restaurant. Multilevel multinomial models were used to estimate the associations between fast food restaurant access and purchasing with never purchased as the reference category. Models were adjusted for confounders including determinants of demand (attitudes and tastes that influence food purchasing decisions as well as individual and area socio-economic characteristics. Results Purchasing fast food on a monthly basis was related to the variety of fast food restaurants (odds ratio 1.13; 95% confidence interval 1.02 – 1.25 after adjusting for individual and area characteristics. Density and proximity were not found to be significant predictors of fast food purchasing after adjustment for individual socio

  16. Balancing fast-rotating parts of hand-held machine drive

    Science.gov (United States)

    Korotkov, V. S.; Sicora, E. A.; Nadeina, L. V.; Yongzheng, Wang

    2018-03-01

    The article considers the issues related to the balancing of fast rotating parts of the hand-held machine drive including a wave transmission with intermediate rolling elements, which is constructed on the basis of the single-phase collector motor with a useful power of 1 kW and a nominal rotation frequency of 15000 rpm. The forms of balancers and their location are chosen. The method of balancing is described. The scheme for determining of residual unbalance in two correction planes is presented. Measurement results are given in tables.

  17. Use of the oral sugar test in ponies when performed with or without prior fasting.

    Science.gov (United States)

    Knowles, E J; Harris, P A; Elliott, J; Menzies-Gow, N J

    2017-07-01

    It is recommended that the oral sugar test (OST) for insulin dysregulation (ID) be performed after an overnight fast, but fasting is impractical in ponies kept solely at pasture. There are few data on OST repeatability and reliability in ponies. To report 1) whether OST results obtained in the morning after an overnight fast or without fasting in the afternoon (FASTING/FED) can be used interchangeably, 2) time of highest insulin concentration T max [insulin], repeatability and reliability of insulin response to the OST when FASTING or FED and 3) dichotomous agreement (ID/normal) within a small sample when FASTING or FED. Method comparison study. Oral sugar tests were performed on four occasions in 10 adult native British ponies, twice FASTING and twice FED. Insulin concentrations were measured by radioimmunoassay at 0-120 min (T 0,30,60,75,90,120 ). Differences between FASTING and FED results were assessed using mixed effects models. Indices of repeatability and reliability were calculated; dichotomous agreement was reported using kappa statistics. Serum [insulin] was significantly (P≤0.05) higher at T 60 -T 90 with prior fasting (estimated differences [95% confidence intervals]): T 60 : 23.5 μiu/ml (8.7-38.4 μiu/ml), T 75 : 27.1 μiu/ml (12.3-41.8 μiu/ml), T 90 : 15.1 (0.36-29.9 μiu/ml). Most frequently, T max [ins] occurred at T 30 . At any single time point, within-subject coefficients of variation were: FASTING: 40% and FED: 31%. The 95% limits for repeatability were FASTING: 29-340%, FED: 41-240%. Test reliabilities were FASTING: 0.70 and FED: 0.67. For dichotomous interpretation similar results (kappa = 0.7) were obtained using cut-offs of [Insulin] >60 μiu/ml at T 60 or T 90 for FASTING and [Insulin] >51 μiu/ml at T 30 or T 60 for FED samples. Oral sugar tests were performed on a small number of animals on one pasture during one season (spring). Clinicians should beware of interpreting changes in absolute OST results owing to poor repeatability. When

  18. The prototype fast reactor

    International Nuclear Information System (INIS)

    Broomfield, A.M.

    1985-01-01

    The paper concerns the Prototype Fast Reactor (PFR), which is a liquid metal cooled fast reactor power station, situated at Dounreay, Scotland. The principal design features of a Fast Reactor and the PFR are given, along with key points of operating history, and health and safety features. The role of the PFR in the development programme for commercial reactors is discussed. (U.K.)

  19. Effect of reactor neutron radiation and temperature on the structure of InP single crystals

    International Nuclear Information System (INIS)

    Bojko, V.M.; Kolin, N.G.; Merkurisov, D.I.; Bublik, V.T.; Voronova, M.I.; Shcherbachev, K.D.

    2006-01-01

    The structural characteristics of InP single crystals have been investigated depending on the radiation effects produced by fast and full spectrum neutrons and subsequent heat treatment. A lattice period in InP single crystals decreases under neutron irradiation. Fast neutrons make the main contribution into the change of the lattice period. Availability of the thermal neutrons initiates the formation of Sn atoms, but does not make a significant influence on the change of the lattice period. Heat treatment of the irradiated samples up to 600 deg C causes the annealing of radiation defects and recovery of the lattice period. With increasing neutron fluences a lattice period becomes even higher than before irradiation [ru

  20. Fast radio bursts: the observational case for a Galactic origin

    OpenAIRE

    Maoz, Dan; Loeb, Abraham; Shvartzvald, Yossi; Sitek, Monika; Engel, Michael; Kiefer, Flavien; Kiraga, Marcin; Levi, Amir; Mazeh, Tsevi; Pawlak, Michal; Rich, R. Michael; Tal-Or, Lev; Wyrzykowski, Lukasz

    2015-01-01

    There are by now ten published detections of fast radio bursts (FRBs), single bright GHz-band millisecond pulses of unknown origin. Proposed explanations cover a broad range from exotic processes at cosmological distances to atmospheric and terrestrial sources. Loeb et al. have previously suggested that FRB sources could be nearby flare stars, and pointed out the presence of a W-UMa-type contact binary within the beam of one out of three FRB fields that they examined. Using time-domain optica...

  1. Photoionisation detection of single 87Rb-atoms using channel electron multipliers

    International Nuclear Information System (INIS)

    Henkel, Florian Alexander

    2011-01-01

    Fast and efficient detection of single atoms is a universal requirement concerning modern experiments in atom physics, quantum optics, and precision spectroscopy. In particular for future quantum information and quantum communication technologies, the efficient readout of qubit states encoded in single atoms or ions is an elementary prerequisite. The rapid development in the field of quantum optics and atom optics in the recent years has enabled to prepare individual atoms as quantum memories or arrays of single atoms as qubit registers. With such systems, the implementation of quantum computation or quantum communication protocols seems feasible. This thesis describes a novel detection scheme which enables fast and efficient state analysis of single neutral atoms. The detection scheme is based on photoionisation and consists of two parts: the hyperfine-state selective photoionisation of single atoms and the registration of the generated photoion-electron pairs via two channel electron multipliers (CEMs). In this work, both parts were investigated in two separate experiments. For the first step, a photoionisation probability of p ion =0.991 within an ionisation time of t ion =386 ns is achieved for a single 87 Rb-atom in an optical dipole trap. For the second part, a compact detection system for the ionisation fragments was developed consisting of two opposing CEM detectors. Measurements show that single neutral atoms can be detected via their ionisation fragments with a detection efficiency of η atom =0.991 within a detection time of t det =415.5 ns. In a future combined setup, this will allow the state-selective readout of optically trapped, single neutral 87 Rb-atoms via photoionisation detection with an estimated detection efficiency η=0.982 and a detection time of t tot = 802 ns. Although initially developed for single 87 Rb-atoms, the concept of photoionisation detection is in principle generally applicable to any atomic or molecular species. As efficient

  2. Trends in Consumption of Solid Fats, Added Sugars, Sodium, Sugar-Sweetened Beverages, and Fruit from Fast Food Restaurants and by Fast Food Restaurant Type among US Children, 2003-2010.

    Science.gov (United States)

    Rehm, Colin D; Drewnowski, Adam

    2016-12-13

    Energy intakes from fast food restaurants (FFRs) have declined among US children. Less is known about the corresponding trends for FFR-sourced solid fats, added sugars, and sodium, and food groups of interest, such as fruit and sugar-sweetened beverages (SSBs). Using data from a single 24-h dietary recall among 12,378 children aged 4-19 years from four consecutive cycles of the nationally-representative National Health and Nutrition Examination Survey (NHANES), 2003-2010 a custom algorithm segmented FFRs into burger, pizza, sandwich, Mexican cuisine, chicken, Asian cuisine, fish restaurants, and coffee shops. There was a significant population-wide decline in FFR-sourced solid fats (-32 kcal/day, p -trend restaurants; added sugars, solid fats, and SSBs declined significantly from burger restaurants. Fruit did not change for fast food restaurants overall. Temporal analyses of fast food consumption trends by restaurant type allow for more precise monitoring of the quality of children's diets than can be obtained from analyses of menu offerings. Such analyses can inform public health interventions and policy measures.

  3. FAST: An advanced code system for fast reactor transient analysis

    International Nuclear Information System (INIS)

    Mikityuk, Konstantin; Pelloni, Sandro; Coddington, Paul; Bubelis, Evaldas; Chawla, Rakesh

    2005-01-01

    One of the main goals of the FAST project at PSI is to establish a unique analytical code capability for the core and safety analysis of advanced critical (and sub-critical) fast-spectrum systems for a wide range of different coolants. Both static and transient core physics, as well as the behaviour and safety of the power plant as a whole, are studied. The paper discusses the structure of the code system, including the organisation of the interfaces and data exchange. Examples of validation and application of the individual programs, as well as of the complete code system, are provided using studies carried out within the context of designs for experimental accelerator-driven, fast-spectrum systems

  4. The JET diagnostic fast central acquisition and trigger system (abstract)

    Science.gov (United States)

    Edwards, A. W.; Blackler, K.

    1995-01-01

    Most plasma physics diagnostics sample at a fixed frequency that is normally matched to available memory limits. This technique is not appropriate for long pulse machines such as JET where sampling frequencies of hundreds of kHz are required to diagnose very fast events. As a result of work using real-time event selection within the previous JET soft x-ray diagnostic, a single data acquisition and event triggering system for all suitable fast diagnostics, the fast central acquisition and trigger system (Fast CATS), has been developed for JET. The front-end analog-to-digital conversion (ADC) part samples all channels at 250 kHz, with a 100 kHz pass band and a stop band of 125 kHz. The back-end data collection system is based around Texas Instruments TMS320C40 microprocessors. Within this system, two levels of trigger algorithms are able to evaluate data. The first level typically analyzes data on a per diagnostic and individual channel basis. The second level looks at the data from one or more diagnostics in a window around the time of interest flagged by the first level system. Selection criteria defined by the diagnosticians are then imposed on the results from the second level to decide whether that data should be kept. The use of such a system involving intelligent real time trigger algorithms and fast data analysis will improve both the quantity and quality of JET diagnostic data, while providing valuable input to the design of data acquisition systems for very long pulse machines such as ITER. This paper will give an overview of the various elements of this new system. In addition, first results from this system following the restart of JET operation will be presented.

  5. Islamic fasting and multiple sclerosis

    Science.gov (United States)

    2014-01-01

    Background Month-long daytime Ramadan fasting pose s major challenges to multiple sclerosis (MS) patients in Muslim countries. Physicians should have practical knowledge on the implications of fasting on MS. We present a summary of database searches (Cochrane Database of Systematic Reviews, PubMed) and a mini-symposium on Ramadan fasting and MS. In this symposium, we aimed to review the effect of fasting on MS and suggest practical guidelines on management. Discussion In general, fasting is possible for most stable patients. Appropriate amendment of drug regimens, careful monitoring of symptoms, as well as providing patients with available evidence on fasting and MS are important parts of management. Evidence from experimental studies suggests that calorie restriction before disease induction reduces inflammation and subsequent demyelination and attenuates disease severity. Fasting does not appear to have unfavorable effects on disease course in patients with mild disability (Expanded Disability Status Scale (EDSS) score ≤3). Most experts believed that during fasting (especially in summer), some MS symptoms (fatigue, fatigue perception, dizziness, spasticity, cognitive problems, weakness, vision, balance, gait) might worsen but return to normal levels during feasting. There was a general consensus that fasting is not safe for patients: on high doses of anti-convulsants, anti-spastics, and corticosteroids; with coagulopathy or active disease; during attacks; with EDSS score ≥7. Summary These data suggest that MS patients should have tailored care. Fasting in MS patients is a challenge that is directly associated with the spiritual belief of the patient. PMID:24655543

  6. Single ionization of helium by fast proton impact: Searching for projectile coherence

    International Nuclear Information System (INIS)

    Gassert, H; Waitz, M; Kim, H-K; Bauer, T; Laucke, A; Müller, Ch; Voigtsberger, J; Weller, M; Rist, J; Pahl, K; Honig, M; Pitzer, M; Zeller, S; Jahnke, T; Schmidt, L Ph H; Schmidt-Böcking, H; Chuluunbaatar, O; Bulychev, A A; Zaytsev, S A; Kouzakov, K A

    2015-01-01

    The fully differential cross section (FDCS) for single ionization p + He → p + e + He + at proton energy of 1 MeV is studied both experimentally and theoretically. The 3D angular electron distribution is presented. The role of electron-electron correlations both in a trial helium ground-state wave function and in the final helium state is inspected. (paper)

  7. Theory of atom displacements induced by fast electron elastic scattering in solids

    International Nuclear Information System (INIS)

    Cruz, C. M.; Pinera, I.; Abreu, Y.; Leyva, A.

    2006-01-01

    Present contribution deals with the theoretical description of the conditions favoring the occurrence of single fast electron elastic scattering in solids, leading to the displacement of atoms from their crystalline sites. Firstly, the Moliere-Bethe-Goudsmit-Saunderson theory of Multiple Electron Scattering is applied, determining the limiting angle θ l over which the single electron elastic scattering prevails over the multiple one, leading to the evaluation of the total macroscopic cross-section for single electron elastic scattering on the basis of the Mott-Rutherford differential cross-section. On the basis of single electron elastic scattering by atoms in the solid matrix, it was determined the relative number of Atom Displacements produced by the Gamma Radiation as a primary act, as well as the energy and linear momentum of the ejected atoms. The statistical distributions of single electron elastic scattering and of those inducing Atom Displacements at different electron initial energies in comparison with the others electron inelastic scattering channels are discussed, where the statistical sampling methods on the basis of the rejection one where applied simulating different practical situations. (Full text)

  8. Direct single-molecule dynamic detection of chemical reactions.

    Science.gov (United States)

    Guan, Jianxin; Jia, Chuancheng; Li, Yanwei; Liu, Zitong; Wang, Jinying; Yang, Zhongyue; Gu, Chunhui; Su, Dingkai; Houk, Kendall N; Zhang, Deqing; Guo, Xuefeng

    2018-02-01

    Single-molecule detection can reveal time trajectories and reaction pathways of individual intermediates/transition states in chemical reactions and biological processes, which is of fundamental importance to elucidate their intrinsic mechanisms. We present a reliable, label-free single-molecule approach that allows us to directly explore the dynamic process of basic chemical reactions at the single-event level by using stable graphene-molecule single-molecule junctions. These junctions are constructed by covalently connecting a single molecule with a 9-fluorenone center to nanogapped graphene electrodes. For the first time, real-time single-molecule electrical measurements unambiguously show reproducible large-amplitude two-level fluctuations that are highly dependent on solvent environments in a nucleophilic addition reaction of hydroxylamine to a carbonyl group. Both theoretical simulations and ensemble experiments prove that this observation originates from the reversible transition between the reactant and a new intermediate state within a time scale of a few microseconds. These investigations open up a new route that is able to be immediately applied to probe fast single-molecule physics or biophysics with high time resolution, making an important contribution to broad fields beyond reaction chemistry.

  9. Dounreay fast reactor

    International Nuclear Information System (INIS)

    Maclennan, R.; Eggar, T.; Skeet, T.

    1992-01-01

    The short debate which followed a private notice question asking for a statement on Government policy on the future of the European fast breeder nuclear research programme is reported verbatim. In response to the question, the Minister for Energy said that the Government had decided in 1988 that the Dounreay prototype fast reactor would close in 1994. That decision had been confirmed. Funding of fast breeder research and development beyond 1993 is not a priority as commercialization is not expected until well into the next century. Dounreay will be supported financially until 1994 and then for its subsequent decommissioning and reprocessing of spent fuel. The debate raised issues such as Britain losing its lead in fast breeder research, loss of jobs and the Government's nuclear policy in general. However, the Government's position was that the research had reached a stage where it could be left and returned to in the future. (UK)

  10. Knowledge management in fast reactors

    International Nuclear Information System (INIS)

    Kuriakose, K.K.; Satya Murty, S.A.V.; Swaminathan, P.; Raj, Baldev

    2010-01-01

    This paper highlights the work that is being carried out in Knowledge Management of Fast Reactors at Indira Gandhi Centre for Atomic Research (IGCAR) including a few examples of how the knowledge acquired because of various incidents in the initial years has been utilized for the successful operation of Fast Breeder Test Reactor. It also briefly refers to the features of the IAEA initiative on the preservation of Knowledge in the area of Fast Reactors in the form of 'Fast Reactor Knowledge Organization System' (FR-KOS), which is based on a taxonomy for storage and mining of Fast Reactor Knowledge. (author)

  11. Influence of fast and slow alkali myosin light chain isoforms on the kinetics of stretch-induced force transients of fast-twitch type IIA fibres of rat.

    Science.gov (United States)

    Andruchov, Oleg; Galler, Stefan

    2008-03-01

    This study contributes to understand the physiological role of slow myosin light chain isoforms in fast-twitch type IIA fibres of skeletal muscle. These isoforms are often attached to the myosin necks of rat type IIA fibres, whereby the slow alkali myosin light chain isoform MLC1s is much more frequent and abundant than the slow regulatory myosin light chain isoform MLC2s. In the present study, single-skinned rat type IIA fibres were maximally Ca(2+) activated and subjected to stepwise stretches for causing a perturbation of myosin head pulling cycles. From the time course of the resulting force transients, myosin head kinetics was deduced. Fibres containing MLC1s exhibited slower kinetics independently of the presence or absence of MLC2s. At the maximal MLC1s concentration of about 75%, the slowing was about 40%. The slowing effect of MLC1s is possibly due to differences in the myosin heavy chain binding sites of the fast and slow alkali MLC isoforms, which changes the rigidity of the myosin neck. Compared with the impact of myosin heavy chain isoforms in various fast-twitch fibre types, the influence of MLC1s on myosin head kinetics of type IIA fibres is much smaller. In conclusion, the physiological role of fast and slow MLC isoforms in type IIA fibres is a fine-tuning of the myosin head kinetics.

  12. Association between proximity to and coverage of traditional fast-food restaurants and non-traditional fast-food outlets and fast-food consumption among rural adults

    OpenAIRE

    Sharkey, Joseph R; Johnson, Cassandra M; Dean, Wesley R; Horel, Scott A

    2011-01-01

    Abstract Objective The objective of this study is to examine the relationship between residential exposure to fast-food entrées, using two measures of potential spatial access: proximity (distance to the nearest location) and coverage (number of different locations), and weekly consumption of fast-food meals. Methods Traditional fast-food restaurants and non-traditional fast-food outlets, such as convenience stores, supermarkets, and grocery stores, from the 2006 Brazos Valley Food Environmen...

  13. Accuracy of a reformulated fast-set vinyl polysiloxane impression material using dual-arch trays.

    Science.gov (United States)

    Kang, Alex H; Johnson, Glen H; Lepe, Xavier; Wataha, John C

    2009-05-01

    A common technique used for making crown impressions involves use of a vinyl polysiloxane impression material in combination with a dual-arch tray. A leading dental manufacturer has reformulated its vinyl polysiloxane (VPS) impression line, but the accuracy of the new material has not been verified. The purpose of this study was to assess the accuracy of reformulated VPS impression materials using the single-step dual-arch impression technique. Dual-arch impressions were made on a typodont containing a master stainless steel standard crown preparation die, from which gypsum working dies were formed, recovered, and measured. The impression materials evaluated were Imprint 3 Penta Putty with Quick Step Regular Body (IP-0); Imprint 3 Penta Quick Step Heavy Body with Quick Step Light Body (IP-1); Aquasil Ultra Rigid Fast Set with LV Fast Set (AQ-1); and Aquasil Ultra Heavy Fast Set with XLV Fast Set (AQ-2) (n=10). All impressions were disinfected with CaviCide spray for 10 minutes prior to pouring with type IV gypsum. Buccolingual (BL), mesiodistal (MD), and occlusogingival (OG) dimensions were measured and compared to the master die using an optical measuring microscope. Linear dimensional change was also assessed for IP-0 and AQ-1 at 1 and 24 hours based on ANSI/ADA Specification No. 19. Single-factor ANOVA with Dunnett's T3 multiple comparisons was used to compare BL, MD, and OG changes, with hypothesis testing at alpha=.05. A repeated-measures ANOVA was used to compare linear dimensional changes. There were statistical differences among the 4 impression systems for 3 of 4 dimensions of the master die. IP-0 working dies were significantly larger in MD and OG-L dimensions but significantly smaller in the BL dimension. IP-1 working dies were significantly smaller in the BL dimension compared to the master die. With the exception of IP-0, differences detected were small and clinically insignificant. No significant differences were observed for linear dimensional change

  14. FastScatTM: An Object-Oriented Program for Fast Scattering Computation

    Directory of Open Access Journals (Sweden)

    Lisa Hamilton

    1993-01-01

    Full Text Available FastScat is a state-of-the-art program for computing electromagnetic scattering and radiation. Its purpose is to support the study of recent algorithmic advancements, such as the fast multipole method, that promise speed-ups of several orders of magnitude over conventional algorithms. The complexity of these algorithms and their associated data structures led us to adopt an object-oriented methodology for FastScat. We discuss the program's design and several lessons learned from its C++ implementation including the appropriate level for object-orientedness in numeric software, maintainability benefits, interfacing to Fortran libraries such as LAPACK, and performance issues.

  15. FAST and SAFE Passive Safety Devices for Sodium-cooled Fast Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hartanto, Donny; Kim, Chihyung; Kim, In-Hyung; Kim, Yonghee [KAIST, Daejeon (Korea, Republic of)

    2015-05-15

    The major factor is the impact of the neutron spectral hardening. The second factor that affects the CVR is reduced capture by the coolant when the coolant voiding occurs. To improve the CVR, many ideas and concepts have been proposed, which include introduction of an internal blanket, spectrum softening, or increasing the neutron leakage. These ideas may reduce the CVR, but they deteriorate the neutron economy. Another potential solution is to adopt a passive safety injection device such as the ARC (autonomous reactivity control) system, which is still under development. In this paper, two new concepts of passive safety devices are proposed. The devices are called FAST (Floating Absorber for Safety at Transient) and SAFE (Static Absorber Feedback Equipment). Their purpose is to enhance the negative reactivity feedback originating from the coolant in fast reactors. SAFE is derived to balance the positive reactivity feedback due to sodium coolant temperature increases. It has been demonstrated that SAFE allows a low-leakage SFR to achieve a self-shutdown and self-controllability even though the generic coolant temperature coefficient is quite positive and the coolant void reactivity can be largely managed by the new FAST device. It is concluded that both FAST and SAFE devices will improve substantially the fast reactor safety and they deserve more detailed investigations.

  16. Detecting earthquakes over a seismic network using single-station similarity measures

    Science.gov (United States)

    Bergen, Karianne J.; Beroza, Gregory C.

    2018-06-01

    New blind waveform-similarity-based detection methods, such as Fingerprint and Similarity Thresholding (FAST), have shown promise for detecting weak signals in long-duration, continuous waveform data. While blind detectors are capable of identifying similar or repeating waveforms without templates, they can also be susceptible to false detections due to local correlated noise. In this work, we present a set of three new methods that allow us to extend single-station similarity-based detection over a seismic network; event-pair extraction, pairwise pseudo-association, and event resolution complete a post-processing pipeline that combines single-station similarity measures (e.g. FAST sparse similarity matrix) from each station in a network into a list of candidate events. The core technique, pairwise pseudo-association, leverages the pairwise structure of event detections in its network detection model, which allows it to identify events observed at multiple stations in the network without modeling the expected moveout. Though our approach is general, we apply it to extend FAST over a sparse seismic network. We demonstrate that our network-based extension of FAST is both sensitive and maintains a low false detection rate. As a test case, we apply our approach to 2 weeks of continuous waveform data from five stations during the foreshock sequence prior to the 2014 Mw 8.2 Iquique earthquake. Our method identifies nearly five times as many events as the local seismicity catalogue (including 95 per cent of the catalogue events), and less than 1 per cent of these candidate events are false detections.

  17. Single Nanowire Probe for Single Cell Endoscopy and Sensing

    Science.gov (United States)

    Yan, Ruoxue

    adaptable to average bio-lab environment. These probes are mechanically robust and flexible and can withstand repeated bending and deformation without significant deterioration in optical performance, which offers an ideal instrumental platform for out subsequent effort of using these nanoprobes in chemical sensing as well as single cell endoscopy and spot delivery. Parameters affecting the coupling efficiency and output power of the nanoprobe were studied and chemical etched of single mode fiber with small cone angle was established to be optimized for highly effective optical nanoprobes. The versatility of the nanoprobe design was first tested by transforming the nanowire probe into a pH sensor with near-field photopolymerization of a copolymer containing pH sensitive dye on the tip of the nanowire. The pH-sensitive nanoprobe was able to report the pH difference in micro-droplets containing buffer solution with the excitation of light waveguided on the nanoprobe with internal calibration, fast response time and good photostability and reversibility. Such nanoprobe sensors are ideal for high definition spatial and temporal sensing of concentration profile, especially for the kinetic processes in single cell studies for which chemical probes of minute sizes and fast response are desired. The nanoprobe was then applied into spot cargo delivery and in-situ single cell endoscopy. It was demonstrated that nanowire-based optical probe can deliver payloads into the cell with a high spatiotemporal precision, guide and confine visible light into intracellular compartments selectively and detect optical signals from the subcellular regions with high spatial resolution. The nanoprobe was proven to be biocompatible and non-invasive. The effective optical coupling between the fiber optics and the nanowire enables highly localized excitation and detection, limiting the probe volume to the close proximity of the nanowire. None the less, this versatile technique does not rely on any

  18. Performance Evaluation of Low/Zero Voltage Ride-Through Operations for Single-Stage Single-Phase Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Zhang, Zhen; Yang, Yongheng; Blaabjerg, Frede

    2017-01-01

    With the fast development of distributed power generations, stability and security have attracted extensive attention in the recent years. As a representative of clean energies, Photovoltaic (PV) systems have been installed extensively worldwide. This drives grid-connected requirements...... to be continuously updated. In current active grid requirements/codes, PV systems should be more intelligent in the considerations of the grid stability, reliability and fault protection. In this paper, two control strategies (i.e., the single-phase PQ control and power phase-angle control) are evaluated for grid...

  19. Fast, microprocessor driven, data acquisition for Fermilab Experiment E-705

    International Nuclear Information System (INIS)

    Conetti, S.; Haire, M.; Kuchela, K.

    1985-01-01

    Data rate in excess of 10 5 16-bit CAMAC words/sec, with peak rates of up to 2X10 6 words/sec, are expected from Fermilab experiment E-705. To handle such rate, a fast Data Acquisition System was designed, composed of several CAMAC Smart Controllers, sending their data, in a combined serial/parallel organization, to a VME based data collection and forwarding system. Such a system, contained in a VME Crate, consists of homebuilt data receiver and transmitter boards, a Motorola VME-110, 68000 based, Single Board Computer acting as a supervisor, and a large (greater than or equal to4 Mbytes) buffer memory. Data filtering capabilities will be added to the system with the inclusion of several MK 75602 Single Board Computers, acting as processing cells

  20. Atomically Smooth Epitaxial Ferroelectric Thin Films for the Development of a Nonvolatile, Ultrahigh Density, Fast, Low Voltage, Radiation-Hard Memory

    National Research Council Canada - National Science Library

    Ahn, Charles H

    2006-01-01

    The goal of this research is to fabricate atomically smooth, single crystalline, complex oxide thin film nanostructures for use in a nonvolatile, ultrahigh density, fast, low voltage, radiation-hard memory...

  1. Energetic-particle-driven instabilities and induced fast-ion transport in a reversed field pinch

    International Nuclear Information System (INIS)

    Lin, L.; Brower, D. L.; Ding, W. X.; Anderson, J. K.; Capecchi, W.; Eilerman, S.; Forest, C. B.; Koliner, J. J.; Nornberg, M. D.; Reusch, J.; Sarff, J. S.; Liu, D.

    2014-01-01

    Multiple bursty energetic-particle (EP) driven modes with fishbone-like structure are observed during 1 MW tangential neutral-beam injection in a reversed field pinch (RFP) device. The distinguishing features of the RFP, including large magnetic shear (tending to add stability) and weak toroidal magnetic field (leading to stronger drive), provide a complementary environment to tokamak and stellarator configurations for exploring basic understanding of EP instabilities. Detailed measurements of the EP mode characteristics and temporal-spatial dynamics reveal their influence on fast ion transport. Density fluctuations exhibit a dynamically evolving, inboard-outboard asymmetric spatial structure that peaks in the core where fast ions reside. The measured mode frequencies are close to the computed shear Alfvén frequency, a feature consistent with continuum modes destabilized by strong drive. The frequency pattern of the dominant mode depends on the fast-ion species. Multiple frequencies occur with deuterium fast ions compared to single frequency for hydrogen fast ions. Furthermore, as the safety factor (q) decreases, the toroidal mode number of the dominant EP mode transits from n=5 to n=6 while retaining the same poloidal mode number m=1. The transition occurs when the m=1, n=5 wave-particle resonance condition cannot be satisfied as the fast-ion safety factor (q fi ) decreases. The fast-ion temporal dynamics, measured by a neutral particle analyzer, resemble a classical predator-prey relaxation oscillation. It contains a slow-growth phase arising from the beam fueling followed by a rapid drop when the EP modes peak, indicating that the fluctuation-induced transport maintains a stiff fast-ion density profile. The inferred transport rate is strongly enhanced with the onset of multiple EP modes

  2. Single administration of recombinant IL-6 restores the gene expression of lipogenic enzymes in liver of fasting IL-6-deficient mice

    DEFF Research Database (Denmark)

    Gavito, A L; Cabello, R; Suarez, J

    2016-01-01

    BACKGROUND AND PURPOSE: Lipogenesis is intimately controlled by hormones and cytokines as well as nutritional conditions. IL-6 participates in the regulation of fatty acid metabolism in the liver. We investigated the role of IL-6 in mediating fasting/re-feeding changes in the expression of hepatic...... lipogenic enzymes. EXPERIMENTAL APPROACH: Gene and protein expression of lipogenic enzymes were examined in livers of wild-type (WT) and IL-6-deficient (IL-6(-/-) ) mice during fasting and re-feeding conditions. Effects of exogenous IL-6 administration on gene expression of these enzymes were evaluated...

  3. Improving Performance of LVRT Capability in Single-phase Grid-tied PV Inverters by a Model Predictive Controller

    DEFF Research Database (Denmark)

    Zangeneh Bighash, Esmaeil; Sadeghzadeh, Seyed Mohammad; Ebrahimzadeh, Esmaeil

    2018-01-01

    dynamic response and stability. To fill in this gap, this paper presents a fast and robust current controller based on a Model-Predictive Control (MPC) for single-phase PV inverters in other to deal with the LVRT operation. In order to confirm the effectiveness of the proposed controller, results...... the voltage sag period is short, a fast dynamic performance along with a soft behavior of the controller is the most important issue in the LVRT duration. Recently, some methods like Proportional Resonant (PR) controllers, have been presented to control the single phase PV systems in LVRT mode. However......, these methods have had uncertainties in respect their contribution in LVRT mode. In PR controllers, a fast dynamic response can be obtained by tuning the gains of PR controllers for a high bandwidth, but typically the phase margin is decreased. Therefore, the design of PR controllers needs a tradeoff between...

  4. A comparison of the Health Star Rating system when used for restaurant fast foods and packaged foods.

    Science.gov (United States)

    Dunford, Elizabeth K; Wu, Jason H Y; Wellard-Cole, Lyndal; Watson, Wendy; Crino, Michelle; Petersen, Kristina; Neal, Bruce

    2017-10-01

    In June 2014, the Australian government agreed to the voluntary implementation of an interpretive 'Health Star Rating' (HSR) front-of-pack labelling system for packaged foods. The aim of the system is to make it easier for consumers to compare the healthiness of products based on number of stars. With many Australians consuming fast food there is a strong rationale for extending the HSR system to include fast food items. To examine the performance of the HSR system when applied to fast foods. Nutrient content data for fast food menu items were collected from the websites of 13 large Australian fast-food chains. The HSR was calculated for each menu item. Statistics describing HSR values for fast foods were calculated and compared to results for comparable packaged foods. Data for 1529 fast food products were compared to data for 3810 packaged food products across 16 of 17 fast food product categories. The mean HSR for the fast foods was 2.5 and ranged from 0.5 to 5.0 and corresponding values for the comparator packaged foods were 2.6 and 0.5 to 5.0. Visual inspection of the data showed broadly comparable distributions of HSR values across the fast food and the packaged food categories, although statistically significant differences were apparent for seven categories (all p fast foods and packaged food, and in others it appeared to reflect primarily differences in the mix of product types within a category. These data support the idea that the HSR system could be extended to Australian fast foods. There are likely to be significant benefits to the community from the use of a single standardised signposting system for healthiness across all fresh, packaged and restaurant foods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Fast switching wideband rectifying circuit for future RF energy harvesting

    Science.gov (United States)

    Asmeida, Akrem; Mustam, Saizalmursidi Md; Abidin, Z. Z.; Ashyap, A. Y. I.

    2017-09-01

    This paper presents the design and simulation of fast switching microwave rectifying circuit for ultra wideband patch antenna over a dual-frequency band (1.8 GHz for GSM and 2.4 GHz for ISM band). This band was chosen due to its high signal availability in the surrounding environment. New rectifying circuit topology with pair-matching trunks is designed using Advanced Design System (ADS) software. These trunks are interfaced with power divider to achieve good bandwidth, fast switching and high efficiency. The power divider acts as a good isolator between the trunks and its straightforward design structure makes it a good choice for a single feed UWB antenna. The simulated results demonstrate that the maximum output voltage is 2.13 V with an input power of -5 dBm. Moreover, the rectifier offers maximum efficiency of 86% for the input power of -5 dBm at given band, which could easily power up wireless sensor networks (WSN) and other small devices sufficiently.

  6. Development of gas-cooled fast reactor and its thermo-hydraulics

    International Nuclear Information System (INIS)

    Kawamura, Hiroshi

    1977-10-01

    Development, thermo-hydraulics and safety of GCFR are reviewed. The Development of Gas-Cooled Fast Reactor (GCFR) utilizes helium technology of HTGR and fuel technology of LMFBR. The breeding ratio of GCFR will be larger than that of LMFBR by about 0.2. Features of GCFR are a fuel with roughened surface to raise the heat transfer and vent system for the pressure equalization in the fuel rod. Helium as coolant of GCFR is chemically stable and stays in the single phase. So, there is no fuel-coolant interaction unlike the case of LMFBR. Since the helium must be pressurized, possibility of a depressurization accident is not negligible. In the United States, a 300MWe demonstration plant program is about to start; the collaboration with European countries is now quite active in this field. Though the development of GCFR started behind that of LMFBR, GCFR is equally promising as a fast breeder reactor. When realized, it will present possibility of a choice between these two. (auth.)

  7. Trends in Consumption of Solid Fats, Added Sugars, Sodium, Sugar-Sweetened Beverages, and Fruit from Fast Food Restaurants and by Fast Food Restaurant Type among US Children, 2003–2010

    Science.gov (United States)

    Rehm, Colin D.; Drewnowski, Adam

    2016-01-01

    Energy intakes from fast food restaurants (FFRs) have declined among US children. Less is known about the corresponding trends for FFR-sourced solid fats, added sugars, and sodium, and food groups of interest, such as fruit and sugar-sweetened beverages (SSBs). Using data from a single 24-h dietary recall among 12,378 children aged 4–19 years from four consecutive cycles of the nationally-representative National Health and Nutrition Examination Survey (NHANES), 2003–2010 a custom algorithm segmented FFRs into burger, pizza, sandwich, Mexican cuisine, chicken, Asian cuisine, fish restaurants, and coffee shops. There was a significant population-wide decline in FFR-sourced solid fats (−32 kcal/day, p-trend restaurants; added sugars, solid fats, and SSBs declined significantly from burger restaurants. Fruit did not change for fast food restaurants overall. Temporal analyses of fast food consumption trends by restaurant type allow for more precise monitoring of the quality of children’s diets than can be obtained from analyses of menu offerings. Such analyses can inform public health interventions and policy measures. PMID:27983573

  8. An Optogenetic Platform for Real-Time, Single-Cell Interrogation of Stochastic Transcriptional Regulation.

    Science.gov (United States)

    Rullan, Marc; Benzinger, Dirk; Schmidt, Gregor W; Milias-Argeitis, Andreas; Khammash, Mustafa

    2018-05-17

    Transcription is a highly regulated and inherently stochastic process. The complexity of signal transduction and gene regulation makes it challenging to analyze how the dynamic activity of transcriptional regulators affects stochastic transcription. By combining a fast-acting, photo-regulatable transcription factor with nascent RNA quantification in live cells and an experimental setup for precise spatiotemporal delivery of light inputs, we constructed a platform for the real-time, single-cell interrogation of transcription in Saccharomyces cerevisiae. We show that transcriptional activation and deactivation are fast and memoryless. By analyzing the temporal activity of individual cells, we found that transcription occurs in bursts, whose duration and timing are modulated by transcription factor activity. Using our platform, we regulated transcription via light-driven feedback loops at the single-cell level. Feedback markedly reduced cell-to-cell variability and led to qualitative differences in cellular transcriptional dynamics. Our platform establishes a flexible method for studying transcriptional dynamics in single cells. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  9. An Open-Loop Grid Synchronization Approach for Single-Phase Applications

    DEFF Research Database (Denmark)

    Golestan, Saeed; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2018-01-01

    in the presence of frequency drifts. This is particularly true in single-phase applications, where the lack of multiple independent input signals makes the implementation of the synchronization technique difficult. The aim of this paper is to develop an effective OLS technique for single-phase power and energy...... applications. The proposed OLS method benefits from a straightforward implementation, a fast dynamic response (a response time less than two cycles of the nominal frequency), and a complete immunity against the DC component in the grid voltage. In addition, the designed OLS method totally blocks (significantly...

  10. Causes And Effects Of Fast Food

    OpenAIRE

    Eman Al-Saad

    2015-01-01

    Fast food affects our life in many aspects. In fact There are many reasons that have been shown why people continuing eating fast food while they knew about its negative effects on their health and family because of eating fast food. The commercial advertisements play a major role in consuming fast food. In this research I will focus on causes and effects of eating fast food.

  11. A Single Phase Doubly Grounded Semi-Z-Source Inverter for Photovoltaic (PV Systems with Maximum Power Point Tracking (MPPT

    Directory of Open Access Journals (Sweden)

    Tofael Ahmed

    2014-06-01

    Full Text Available In this paper, a single phase doubly grounded semi-Z-source inverter with maximum power point tracking (MPPT is proposed for photovoltaic (PV systems. This proposed system utilizes a single-ended primary inductor (SEPIC converter as DC-DC converter to implement the MPPT algorithm for tracking the maximum power from a PV array and a single phase semi-Z-source inverter for integrating the PV with AC power utilities. The MPPT controller utilizes a fast-converging algorithm to track the maximum power point (MPP and the semi-Z-source inverter utilizes a nonlinear SPWM to produce sinusoidal voltage at the output. The proposed system is able to track the MPP of PV arrays and produce an AC voltage at its output by utilizing only three switches. Experimental results show that the fast-converging MPPT algorithm has fast tracking response with appreciable MPP efficiency. In addition, the inverter shows the minimization of common mode leakage current with its ground sharing feature and reduction of the THD as well as DC current components at the output during DC-AC conversion.

  12. Numerical calculation of high frequency fast wave current drive in a reactor grade tokamak

    International Nuclear Information System (INIS)

    Ushigusa, Kenkichi; Hamamatsu, Kiyotaka

    1988-02-01

    A fast wave current drive with a high frequency is estimated for a reactor grade tokamak by the ray tracing and the quasi-linear Fokker-Planck calculations with an assumption of single path absorption. The fast wave can drive RF current with the drive efficiency of η CD = n-bar e (10 19 m -3 )I RC (A)R(m)/P RF (W) ∼ 3.0 when the wave frequency is selected to be f/f ci > 7. A sharp wave spectrum and a ph|| >/υ Te ∼ 3.0 are required to obtain a good efficiency. A center peaked RF current profile can be formed with an appropriate wave spectrum even in the high temperature plasma. (author)

  13. Ultra-fast Sensor for Single-photon Detection in a Wide Range of the Electromagnetic Spectrum

    Directory of Open Access Journals (Sweden)

    Astghik KUZANYAN

    2016-12-01

    Full Text Available The results of computer simulation of heat distribution processes taking place after absorption of single photons of 1 eV-1 keV energy in three-layer sensor of the thermoelectric detector are being analyzed. Different geometries of the sensor with tungsten absorber, thermoelectric layer of cerium hexaboride and tungsten heat sink are considered. It is shown that by changing the sizes of the sensor layers it is possible to obtain transducers for registration of photons within the given spectral range with required energy resolution and count rate. It is concluded that, as compared to the single layer sensor, the thee-layer sensor has a number of advantages and demonstrate characteristics that make possible to consider the thermoelectric detector as a real alternative to superconducting single photon detectors.

  14. Metabolism and thermoregulation during fasting in king penguins, Aptenodytes patagonicus, in air and water.

    Science.gov (United States)

    Fahlman, A; Schmidt, A; Handrich, Y; Woakes, A J; Butler, P J

    2005-09-01

    We measured oxygen consumption rate (Vo(2)) and body temperatures in 10 king penguins in air and water. Vo(2) was measured during rest and at submaximal and maximal exercise before (fed) and after (fasted) an average fasting duration of 14.4 +/- 2.3 days (mean +/- 1 SD, range 10-19 days) in air and water. Concurrently, we measured subcutaneous temperature and temperature of the upper (heart and liver), middle (stomach) and lower (intestine) abdomen. The mean body mass (M(b)) was 13.8 +/- 1.2 kg in fed and 11.0 +/- 0.6 kg in fasted birds. After fasting, resting Vo(2) was 93% higher in water than in air (air: 86.9 +/- 8.8 ml/min; water: 167.3 +/- 36.7 ml/min, P water in fed animals (air: 117.1 +/- 20.0 ml O(2)/min; water: 114.8 +/- 32.7 ml O(2)/min, P > 0.6). In air, Vo(2) decreased with M(b), while it increased with M(b) in water. Body temperature did not change with fasting in air, whereas in water, there were complex changes in the peripheral body temperatures. These latter changes may, therefore, be indicative of a loss in body insulation and of variations in peripheral perfusion. Four animals were given a single meal after fasting and the temperature changes were partly reversed 24 h after refeeding in all body regions except the subcutaneous, indicating a rapid reversal to a prefasting state where body heat loss is minimal. The data emphasize the importance in considering nutritional status when studying king penguins and that the fasting-related physiological changes diverge in air and water.

  15. Fast breeder reactor research

    International Nuclear Information System (INIS)

    1975-01-01

    Full text: The meeting was attended by 15 participants from seven countries and two international organizations. The Eighth Annual Meeting of the International Working Group on Fast Reactors (IWGFR) was attended by representatives from France, Fed. Rep. Germany, Italy, Japan, United Kingdom, Union of Soviet Socialist Republics and the United States of America - countries that have made significant progress in developing the technology and physics of sodium cooled fast reactors and have extensive national programmes in this field - as well as by representatives of the Commission of the European Communities and the IAEA. The design of fast-reactor power plants is a more difficult task than developing facilities with thermal reactors. Different reactor kinetics and dynamics, a hard neutron spectrum, larger integral doses of fuel and structural material irradiation, higher core temperatures, the use of an essentially novel coolant, and, as a result of all these factors, the additional reliability and safety requirements that are imposed on the planning and operation of sodium cooled fast reactors - all these factors pose problems that can be solved comprehensively only by countries with a high level of scientific and technical development. The exchange of experience between these countries and their combined efforts in solving the fundamental problems that arise in planning, constructing and operating fast reactors are promoting technical progress and reducing the relative expenditure required for various studies on developing and introducing commercial fast reactors. For this reason, the meeting concentrated on reviewing and discussing national fast reactor programmes. The situation with regard to planning, constructing and operating fast experimental and demonstration reactors in the countries concerned, the experience accumulated in operating them, the difficulties arising during operation and ways of over-coming them, the search for optimal designs for the power

  16. A contribution to the design of fast code converters for position encoders

    Science.gov (United States)

    Denic, Dragan B.; Dincic, Milan R.; Miljkovic, Goran S.; Peric, Zoran H.

    2016-10-01

    Pseudorandom binary sequences (PRBS) are very useful in many areas of applications. Absolute position encoders based on PRBS have many advantages. However, the pseudorandom code is not directly applicable to the digital electronic systems, hence a converter from pseudorandom to natural binary code is needed. Recently, a fast pseudorandom/natural code converter based on Galois PRBS generator (much faster than previously used converter based on Fibonacci PRBS generator) was proposed. One of the main parts of the Galois code converter is an initial logic. The problem of the design of the initial logic has been solved only for some single values of resolution, but it is still not solved for any value of resolution, which significantly limits the applicability of the fast Galois code converter. This paper solves this problem presenting the solution for the design of the initial logic of the fast Galois pseudorandom/natural code converters used in the pseudorandom position encoders, in general manner, that is for any value of the resolution, allowing for a wide applicability of the fast Galois pseudorandom position encoders. Rigorous mathematical derivation of the formula for the designing of the initial logic is presented. Simulation of the proposed converter is performed in NI MultiSim software. The proposed solution, although developed for pseudorandom position encoders, can be used in many other fields where PRBS are used.

  17. Power deposition by neutral beam injected fast ions in field-reversed configurations

    International Nuclear Information System (INIS)

    Takahashi, Toshiki; Kato, Takayuki; Kondoh, Yoshiomi; Iwasawa, Naotaka

    2004-01-01

    The effects of Coulomb collisions on neutral beam (NB) injected fast ions into field-reversed configuration (FRC) plasmas are investigated by calculating the single particle orbits, where the ions are subject to the slowing-down and pitch-angle collisions. The Monte Carlo method is used for the pitch-angle scattering, and the friction term is added to the equation of motion to show the effects of the slowing-down collision, such as the deposited power profile. The calculation parameters used are relevant to the NB injection on the FRC injection experiment device [T. Asai, Y. Suzuki, T. Yoneda, F. Kodera, M. Okubo, and S. Goto, Phys. Plasmas 7, 2294 (2000)]. It is found that the dominant local power deposition occurs in the open field region between the X point and the mirror point because of a concentration of fast ions and a longer duration travel at the mirror reflection point. In the present calculation, the maximum deposited power to the FRC plasma is about 10% of the injected power. Although the pitch-angle scattering by Coulomb collision destroys the mirror confinement of NB injected fast ions, this effect is found to be negligible. The loss mechanism due to nonadiabatic fast ion motion, which is intrinsic in nonuniform FRC plasmas, has a much greater effect than the pitch-angle scattering by Coulomb collision

  18. Fast reactors: potential for power

    International Nuclear Information System (INIS)

    1983-02-01

    The subject is discussed as follows: basic facts about conventional and fast reactors; uranium economy; plutonium and fast reactors; cooling systems; sodium coolant; safety engineering; handling and recycling plutonium; safeguards; development of fast reactors in Britain and abroad; future progress. (U.K.)

  19. A fast EM algorithm for BayesA-like prediction of genomic breeding values.

    Directory of Open Access Journals (Sweden)

    Xiaochen Sun

    Full Text Available Prediction accuracies of estimated breeding values for economically important traits are expected to benefit from genomic information. Single nucleotide polymorphism (SNP panels used in genomic prediction are increasing in density, but the Markov Chain Monte Carlo (MCMC estimation of SNP effects can be quite time consuming or slow to converge when a large number of SNPs are fitted simultaneously in a linear mixed model. Here we present an EM algorithm (termed "fastBayesA" without MCMC. This fastBayesA approach treats the variances of SNP effects as missing data and uses a joint posterior mode of effects compared to the commonly used BayesA which bases predictions on posterior means of effects. In each EM iteration, SNP effects are predicted as a linear combination of best linear unbiased predictions of breeding values from a mixed linear animal model that incorporates a weighted marker-based realized relationship matrix. Method fastBayesA converges after a few iterations to a joint posterior mode of SNP effects under the BayesA model. When applied to simulated quantitative traits with a range of genetic architectures, fastBayesA is shown to predict GEBV as accurately as BayesA but with less computing effort per SNP than BayesA. Method fastBayesA can be used as a computationally efficient substitute for BayesA, especially when an increasing number of markers bring unreasonable computational burden or slow convergence to MCMC approaches.

  20. Positron annihilation study of vacancy-type defects in fast-neutron-irradiated MgO·nAl2O3

    International Nuclear Information System (INIS)

    Rahman, Abu Zayed Mohammad Saliqur; Li, Zhuoxin; Cao, Xingzhong; Wang, Baoyi; Wei, Long; Xu, Qiu; Atobe, Kozo

    2014-01-01

    Highlights: •Detection of Al monovacancy by positron lifetime spectroscopy in fast neutron-irradiated MgO·nAl 2 O 3 (n=2). •Concentration of defects is also estimated for Al monovacancy. •O atom peak was observed by using coincidence Doppler broadening spectroscopy. -- Abstract: The positron lifetimes of fast-neutron-irradiated MgO·nAl 2 O 3 single crystals were measured to investigate the formation of cation vacancies. Al monovacancy was possibly observed in samples irradiated by fast neutrons at ultra-low temperatures. Additionally, vacancy-oxygen complex centers were possibly observed in samples irradiated at higher temperatures and fast neutron fluences. Coincidence Doppler broadening (CDB) spectra were measured to obtain information regarding the vicinity of vacancy-type defects. A peak at approximately 11 × 10 −3 m 0 c was observed, which may be due to the presence of oxygen atoms in the neighborhood of the vacancies

  1. Fast clustering using adaptive density peak detection.

    Science.gov (United States)

    Wang, Xiao-Feng; Xu, Yifan

    2017-12-01

    Common limitations of clustering methods include the slow algorithm convergence, the instability of the pre-specification on a number of intrinsic parameters, and the lack of robustness to outliers. A recent clustering approach proposed a fast search algorithm of cluster centers based on their local densities. However, the selection of the key intrinsic parameters in the algorithm was not systematically investigated. It is relatively difficult to estimate the "optimal" parameters since the original definition of the local density in the algorithm is based on a truncated counting measure. In this paper, we propose a clustering procedure with adaptive density peak detection, where the local density is estimated through the nonparametric multivariate kernel estimation. The model parameter is then able to be calculated from the equations with statistical theoretical justification. We also develop an automatic cluster centroid selection method through maximizing an average silhouette index. The advantage and flexibility of the proposed method are demonstrated through simulation studies and the analysis of a few benchmark gene expression data sets. The method only needs to perform in one single step without any iteration and thus is fast and has a great potential to apply on big data analysis. A user-friendly R package ADPclust is developed for public use.

  2. A Fast CVD Diamond Beam Loss Monitor for LHC

    CERN Document Server

    Griesmayer, E; Dobos, D; Effinger, E; Pernegger, H

    2011-01-01

    Chemical Vapour Deposition (CVD) diamond detectors were installed in the collimation area of the CERN LHC to study their feasibility as Fast Beam Loss Monitors in a high-radiation environment. The detectors were configured with a fast, radiation-hard pre-amplifier with a bandwidth of 2 GHz. The readout was via an oscilloscope with a bandwidth of 1 GHz and a sampling rate of 5 GSPS. Despite the 250 m cable run from the detectors to the oscilloscope, single MIPs were resolved with a 2 ns rise time, a pulse width of 10 ns and a time resolution of less than 1 ns. Two modes of operation were applied. For the analysis of unexpected beam aborts, the loss profile was recorded in a 1 ms buffer and, for nominal operation, the histogram of the time structure of the losses was recorded in synchronism with the LHC period of 89.2 μs. Measurements during the LHC start-up (February to December 2010) are presented. The Diamond Monitors gave an unprecedented insight into the time structure of the beam losses resolving the 400...

  3. Causes And Effects Of Fast Food

    Directory of Open Access Journals (Sweden)

    Eman Al-Saad

    2015-08-01

    Full Text Available Fast food affects our life in many aspects. In fact There are many reasons that have been shown why people continuing eating fast food while they knew about its negative effects on their health and family because of eating fast food. The commercial advertisements play a major role in consuming fast food. In this research I will focus on causes and effects of eating fast food.

  4. MR imaging of colorectal carcinomas using an MR endoscopic coil

    International Nuclear Information System (INIS)

    Murano, Akihiko; Kido, Choichiro; Sasaki, Fumio; Nakamura, Tsuneya; Kobayashi, Semi; Katoh, Tomoyuki; Hirai, Takashi

    1994-01-01

    Diagnosis of the depth of wall invasion by rectal carcinoma using MR endoscopy was performed in ten resected specimens, including five rectal carcinomas, three colon carcinomas, two normal gastric wall. In addition, the gastric wall of a pig was examined. MR imaging was done with a 1.5-T Signa Advantage (GE Medical System) system, with the surface coil of the MR endoscope acting as the receiver coil. Five layers could be distinguished in the bowel wall: mucosa, submucosa and muscularis propria divided into circular muscle, longitudinal muscle and intervening connective tissue. Tumors had almost the same signal intensity as muscle. The MR images of colon carcinomas, rectal carcinomas, and extrinsically metastatic involvement of the sigmoid colon by rectal carcinoma all correlated well with the pathological findings. The normal structure of the gastric wall was similar to that of the colon. 3D-fast Spoiled Grass (SPGR) sequence has a fairly short scanning time. Thus, the possibility of precise clinical diagnosis by this method was suggested. (author)

  5. Experimental and numerical studies of the fast ions confined in TFR 600 during fast neutrals injection

    International Nuclear Information System (INIS)

    Gagey, B.

    1980-08-01

    We present a comparison between experimental fast neutrals spectrum measured with a very simple electrostatic analyzer which has been absolutely calibrated, spectrum obtained during fast neutrals injection in TFR 600, and numerical fast neutrals spectrum obtained from a modified Monte-Carlo calculation code. This comparison allows us to draw important conclusions on the fast ions behavior in the plasma

  6. Role of therapeutic fasting along with other Naturopathy and Yoga Modalities in addressing acne vulgaris – A single case report

    Directory of Open Access Journals (Sweden)

    Pushparaj Ameya

    2017-09-01

    Full Text Available A 23 year old female diagnosed as acne vulgaris underwent Therapeutic fasting (TF and other naturopathy and yoga modalities for 30 days. She presented with eruptions all over her face and the face was edematous. She was given a modified diet for initial 3 days which included fresh fruits and juices along with cooked vegetables and sorghum roti. Additionally Naturopathy treatments like Swedish massage, steam bath, warm water enema and hip bath were given along with some yogic postures, pranayam and kriyas (Cleansing procedures. The patient responded well to the therapeutic fasting. By the end of 30 days there were no eruptions in her face and her skin also was clear. All the treatments were based on the principle of naturopathic medicine that the body has its own power to heal itself. TF has shown to attenuate inflammatory status of the body by suppressing pro-inflammatory cytokine expression and decreasing body fat and circulating levels of leukocytes. This is the first study to report the non pharmacological approach towards treating acne. To conclude fasting along with other naturopathy and yoga modalities has shown noteworthy changes in reducing the inflammatory response in acne vulgaris. However large scale studies are warranted.

  7. Polymorphism of myofibrillar proteins of rabbit skeletal-muscle fibres. An electrophoretic study of single fibres.

    OpenAIRE

    Salviati, G; Betto, R; Danieli Betto, D

    1982-01-01

    Rabbit predominantly fast-twitch-fibre and predominantly slow-twitch-fibre skeletal muscles of the hind limbs, the psoas, the diaphragm and the masseter muscles were fibre-typed by one-dimensional polyacrylamide-gel electrophoresis of the myofibrillar proteins of chemically skinned single fibres. Investigation of the distribution of fast-twitch-fibre and slow-twitch-fibre isoforms of myosin light chains and the type of myosin heavy chains, based on peptide 'maps' published in Cleveland. Fisch...

  8. Intermediate and fast neutron absorbed doses in fast neutron field at the RB reactor

    International Nuclear Information System (INIS)

    Sokcic-Kostic, M.; Pesic, M.; Antic, D.

    1987-10-01

    The experimental fuel channel EFC is created as one of the fast neutron fields at the RB reactor. The intermediate and fast neutron spectra in EFC are measured by activation technique. The intermediate and fast neutron absorbed doses are computed on the basis of these experimental results. At the end the obtained doses are compared. (author)

  9. A fast-slow logic system

    International Nuclear Information System (INIS)

    Kawashima, Hideo.

    1977-01-01

    A fast-slow logic system has been made for use in multi-detector experiments in nuclear physics such as particle-gamma and particle-particle coincidence experiments. The system consists of a fast logic system and a slow logic system. The fast logic system has a function of fast coincidences and provides timing signals for the slow logic system. The slow logic system has a function of slow coincidences and a routing control of input analog signals to the ADCs. (auth.)

  10. Single cell adhesion force measurement for cell viability identification using an AFM cantilever-based micro putter

    Science.gov (United States)

    Shen, Yajing; Nakajima, Masahiro; Kojima, Seiji; Homma, Michio; Kojima, Masaru; Fukuda, Toshio

    2011-11-01

    Fast and sensitive cell viability identification is a key point for single cell analysis. To address this issue, this paper reports a novel single cell viability identification method based on the measurement of single cell shear adhesion force using an atomic force microscopy (AFM) cantilever-based micro putter. Viable and nonviable yeast cells are prepared and put onto three kinds of substrate surfaces, i.e. tungsten probe, gold and ITO substrate surfaces. A micro putter is fabricated from the AFM cantilever by focused ion beam etching technique. The spring constant of the micro putter is calibrated using the nanomanipulation approach. The shear adhesion force between the single viable or nonviable cell and each substrate is measured using the micro putter based on the nanorobotic manipulation system inside an environmental scanning electron microscope. The adhesion force is calculated based on the deflection of the micro putter beam. The results show that the adhesion force of the viable cell to the substrate is much larger than that of the nonviable cell. This identification method is label free, fast, sensitive and can give quantitative results at the single cell level.

  11. Predictors of Ramadan fasting during pregnancy

    Directory of Open Access Journals (Sweden)

    Lily A. van Bilsen

    2016-12-01

    Full Text Available Although the health effects of Ramadan fasting during pregnancy are still unclear, it is important to identify the predictors and motivational factors involved in women’s decision to observe the fast. We investigated these factors in a cross sectional study of 187 pregnant Muslim women who attended antenatal care visits in the Budi Kemuliaan Hospital, Jakarta, Indonesia. The odds of adherence to fasting were reduced by 4% for every week increase in gestational age during Ramadan [odds ratio (OR 0.96; 95% confidence interval (CI 0.92, 1.00; p = 0.06] and increased by 10% for every one unit increase of women’s prepregnancy body mass index (BMI (OR 1.10; 95% CI 0.99, 1.23; p = 0.08. Nonparticipation was associated with opposition from husbands (OR 0.34; 95% CI 0.14, 0.82; p = 0.02 and with women’s fear of possible adverse effects of fasting on their own or the baby’s health (OR 0.47; 95% CI 0.22, 1.01; p = 0.05 and OR 0.43; 95% CI 0.21, 0.89; p = 0.02, respectively, although they were attenuated in multivariable analysis. Neither age, income, education, employment, parity, experience of morning sickness, nor fasting during pregnancy outside of Ramadan determined fasting during pregnancy. Linear regression analysis within women who fasted showed that the number of days fasted were inversely associated with women’s gestational age, fear of possible adverse effects of fasting on their own or the fetal health, and with opposition from husbands. In conclusion, earlier gestational age during Ramadan, husband’s opinion and possibly higher prepregnancy BMI, influence women’s adherence to Ramadan fasting during pregnancy. Fear of adverse health effects of Ramadan fasting is common in both fasting and non-fasting pregnant women.

  12. 磁共振断层血管成像在颅神经血管压迫综合征的应用%Magnetic resonance tomographic angiography in cranial neurovascular compression syndrome

    Institute of Scientific and Technical Information of China (English)

    胡兴荣; 李顺振; 邓民强; 陈华东; 邱妮妮

    2010-01-01

    Objective To investigate the clinical diagnostic value of magnetic resonance tomographic angiography (MRTA) on cranial neurovascular compression syndrome,and evaluate the ability of 3D-FIESTA and 3D-TOF-SPGR sequences in demonstrating the relation of three-dimensional space between cranial nerves and blood vessels.Methods The data of 41 patients with cranial neurovascular compression syndrome,admitted to our hospital from May 2007 to May 2009,were analyzed.These patients were planed to perform micro vasular decompression (MVD).Before the operation,MRTA,3D-FIESTA and 3D-TOF-SPGR sequence scanning were performed to observe the relation of three-dimensional space between cranial nerves and blood vessels;these results were compared with the intraoperative results to evaluate the advantages and disadvantages of 3D-FIESTA and 3D-TOF-SPGR sequence scanning.Results MRTA could demonstrate such cranial nerves as trigeminal nerve,facial nerve and glossopharyngeal nerve,and responsible blood vessels clearly and simultaneously.The 3D-FIESTA imaging showed high signal in the cerebrospinal fluid and moderate signal in the nerves and blood vessels.The 3D-TOF-SPGR imaging showed low signal in the cerebrospinai fluid,moderate signal in the nerves and brain parenchyma,and high signal in the blood vessels.Closed relation between the nerves and the blood vessels in the lesion side were found in 34 patients (82.9%) by 3D-FIESTA sequence scanning,and that was found in 35 patients by 3D-TOF-SPGR sequence scanning; no significant difference between 3D-FIESTA and 3D-TOF-SPGR sequence scanning was found in displaying the relation of nerves and blood vessels (P>0.05).Conclusion MRTA technology may clearly show the relation of cranial nerves and responsible blood vessels;combined application of 3D-FIESTA and 3D-TOF-SPGR sequence scanning can help making the preoperative diagnosis and determining the surgical indications in patients with cranial neurovaseular compression syndrome.%目的

  13. Adaptive Hybrid Visual Servo Regulation of Mobile Robots Based on Fast Homography Decomposition

    Directory of Open Access Journals (Sweden)

    Chunfu Wu

    2015-01-01

    Full Text Available For the monocular camera-based mobile robot system, an adaptive hybrid visual servo regulation algorithm which is based on a fast homography decomposition method is proposed to drive the mobile robot to its desired position and orientation, even when object’s imaging depth and camera’s position extrinsic parameters are unknown. Firstly, the homography’s particular properties caused by mobile robot’s 2-DOF motion are taken into account to induce a fast homography decomposition method. Secondly, the homography matrix and the extracted orientation error, incorporated with the desired view’s single feature point, are utilized to form an error vector and its open-loop error function. Finally, Lyapunov-based techniques are exploited to construct an adaptive regulation control law, followed by the experimental verification. The experimental results show that the proposed fast homography decomposition method is not only simple and efficient, but also highly precise. Meanwhile, the designed control law can well enable mobile robot position and orientation regulation despite the lack of depth information and camera’s position extrinsic parameters.

  14. Upgrading ATLAS Fast Calorimeter Simulation

    CERN Document Server

    Heath, Matthew Peter; The ATLAS collaboration

    2017-01-01

    Producing the very large samples of simulated events required by many physics and performance studies with the ATLAS detector using the full GEANT4 detector simulation is highly CPU intensive. Fast simulation tools are a useful way of reducing CPU requirements when detailed detector simulations are not needed. During the LHC Run-1, a fast calorimeter simulation (FastCaloSim) was successfully used in ATLAS. FastCaloSim provides a simulation of the particle energy response at the calorimeter read-out cell level, taking into account the detailed particle shower shapes and the correlations between the energy depositions in the various calorimeter layers. It is interfaced to the standard ATLAS digitization and reconstruction software, and it can be tuned to data more easily than Geant4. Now an improved version of FastCaloSim is in development, incorporating the experience with the version used during Run-1. The new FastCaloSim aims to overcome some limitations of the first version by improving the description of s...

  15. The Fast Simulation Chain for ATLAS

    CERN Document Server

    Basalaev, Artem; The ATLAS collaboration

    2016-01-01

    In order to generate the huge number of Monte Carlo events that will be required by the ATLAS experiment over the next several runs, a very fast simulation is critical. Fast detector simulation alone, however, is insufficient: with very high numbers of simultaneous proton-proton collisions expected in Run 3 and beyond, the digitization (detector response emulation) and event reconstruction time quickly become comparable to the time required for detector simulation. The ATLAS Fast Chain simulation has been developed to solve this problem. Modules are implemented for fast simulation, fast digitization, and fast track reconstruction. The application is sufficiently fast -- several orders of magnitude faster than the standard simulation -- that the simultaneous proton-proton collisions can be generated during the simulation job, so Pythia8 also runs concurrently with the rest of the algorithms. The Fast Chain has been built to be extremely modular and flexible, so that each sample can be custom-tailored to match ...

  16. Fast and Flexible Successive-Cancellation List Decoders for Polar Codes

    Science.gov (United States)

    Hashemi, Seyyed Ali; Condo, Carlo; Gross, Warren J.

    2017-11-01

    Polar codes have gained significant amount of attention during the past few years and have been selected as a coding scheme for the next generation of mobile broadband standard. Among decoding schemes, successive-cancellation list (SCL) decoding provides a reasonable trade-off between the error-correction performance and hardware implementation complexity when used to decode polar codes, at the cost of limited throughput. The simplified SCL (SSCL) and its extension SSCL-SPC increase the speed of decoding by removing redundant calculations when encountering particular information and frozen bit patterns (rate one and single parity check codes), while keeping the error-correction performance unaltered. In this paper, we improve SSCL and SSCL-SPC by proving that the list size imposes a specific number of bit estimations required to decode rate one and single parity check codes. Thus, the number of estimations can be limited while guaranteeing exactly the same error-correction performance as if all bits of the code were estimated. We call the new decoding algorithms Fast-SSCL and Fast-SSCL-SPC. Moreover, we show that the number of bit estimations in a practical application can be tuned to achieve desirable speed, while keeping the error-correction performance almost unchanged. Hardware architectures implementing both algorithms are then described and implemented: it is shown that our design can achieve 1.86 Gb/s throughput, higher than the best state-of-the-art decoders.

  17. Photoionisation detection of single {sup 87}Rb-atoms using channel electron multipliers

    Energy Technology Data Exchange (ETDEWEB)

    Henkel, Florian Alexander

    2011-09-02

    Fast and efficient detection of single atoms is a universal requirement concerning modern experiments in atom physics, quantum optics, and precision spectroscopy. In particular for future quantum information and quantum communication technologies, the efficient readout of qubit states encoded in single atoms or ions is an elementary prerequisite. The rapid development in the field of quantum optics and atom optics in the recent years has enabled to prepare individual atoms as quantum memories or arrays of single atoms as qubit registers. With such systems, the implementation of quantum computation or quantum communication protocols seems feasible. This thesis describes a novel detection scheme which enables fast and efficient state analysis of single neutral atoms. The detection scheme is based on photoionisation and consists of two parts: the hyperfine-state selective photoionisation of single atoms and the registration of the generated photoion-electron pairs via two channel electron multipliers (CEMs). In this work, both parts were investigated in two separate experiments. For the first step, a photoionisation probability of p{sub ion}=0.991 within an ionisation time of t{sub ion}=386 ns is achieved for a single {sup 87}Rb-atom in an optical dipole trap. For the second part, a compact detection system for the ionisation fragments was developed consisting of two opposing CEM detectors. Measurements show that single neutral atoms can be detected via their ionisation fragments with a detection efficiency of {eta}{sub atom}=0.991 within a detection time of t{sub det}=415.5 ns. In a future combined setup, this will allow the state-selective readout of optically trapped, single neutral {sup 87}Rb-atoms via photoionisation detection with an estimated detection efficiency {eta}=0.982 and a detection time of t{sub tot} = 802 ns. Although initially developed for single {sup 87}Rb-atoms, the concept of photoionisation detection is in principle generally applicable to any

  18. Fast and accurate methods for the performance testing of highly-efficient c-Si photovoltaic modules using a 10 ms single-pulse solar simulator and customized voltage profiles

    International Nuclear Information System (INIS)

    Virtuani, A; Rigamonti, G; Friesen, G; Chianese, D; Beljean, P

    2012-01-01

    Performance testing of highly efficient, highly capacitive c-Si modules with pulsed solar simulators requires particular care. These devices in fact usually require a steady-state solar simulator or pulse durations longer than 100–200 ms in order to avoid measurement artifacts. The aim of this work was to validate an alternative method for the testing of highly capacitive c-Si modules using a 10 ms single pulse solar simulator. Our approach attempts to reconstruct a quasi-steady-state I–V (current–voltage) curve of a highly capacitive device during one single 10 ms flash by applying customized voltage profiles–-in place of a conventional V ramp—to the terminals of the device under test. The most promising results were obtained by using V profiles which we name ‘dragon-back’ (DB) profiles. When compared to the reference I–V measurement (obtained by using a multi-flash approach with approximately 20 flashes), the DB V profile method provides excellent results with differences in the estimation of P max (as well as of I sc , V oc and FF) below ±0.5%. For the testing of highly capacitive devices the method is accurate, fast (two flashes—possibly one—required), cost-effective and has proven its validity with several technologies making it particularly interesting for in-line testing. (paper)

  19. Fast-track totalknæalloplastik

    DEFF Research Database (Denmark)

    Gromov, Kirill; Kristensen, Billy B; Jørgensen, Christoffer Calov

    2017-01-01

    patients are eligible for fast-track TKA, and hence the fast-track concept should be standard at all joint replacement facilities. Future challenges of fast-track TKA include safe introduction of outpatient protocols, acute and chronic pain after surgery and optimal utilization of post......Fast-track total knee arthroplasty (TKA) is a well-established concept including optimized logistics and evidence-based treatment, focusing on minimizing surgical stress and improved post-operative recovery, thus leading to lower mortality and morbidity as well as high patient satisfaction. All...

  20. Analysis of Product Complexity considering Disruption Cost in Fast Fashion Supply Chain

    OpenAIRE

    Sardar, Shaheen; Lee, Young Hae

    2015-01-01

    Outsourcing in the textile industry has been playing an important role in the global economy for six decades. Recently, reshoring is an emerging trend due to various complexities involved in supply chain management. As compared with basic textile and apparel products, fast fashion products are complex in their own way. A single assortment contains several new styles, colors, and sizes with unpredictable demand and urgent deadlines. Numerous assortments run simultaneously in the supply chain. ...

  1. High-Fidelity Single-Shot Toffoli Gate via Quantum Control.

    Science.gov (United States)

    Zahedinejad, Ehsan; Ghosh, Joydip; Sanders, Barry C

    2015-05-22

    A single-shot Toffoli, or controlled-controlled-not, gate is desirable for classical and quantum information processing. The Toffoli gate alone is universal for reversible computing and, accompanied by the Hadamard gate, forms a universal gate set for quantum computing. The Toffoli gate is also a key ingredient for (nontopological) quantum error correction. Currently Toffoli gates are achieved by decomposing into sequentially implemented single- and two-qubit gates, which require much longer times and yields lower overall fidelities compared to a single-shot implementation. We develop a quantum-control procedure to construct a single-shot Toffoli gate for three nearest-neighbor-coupled superconducting transmon systems such that the fidelity is 99.9% and is as fast as an entangling two-qubit gate under the same realistic conditions. The gate is achieved by a nongreedy quantum control procedure using our enhanced version of the differential evolution algorithm.

  2. Overview of tritium fast-fission yields

    International Nuclear Information System (INIS)

    Tanner, J.E.

    1981-03-01

    Tritium production rates are very important to the development of fast reactors because tritium may be produced at a greater rate in fast reactors than in light water reactors. This report focuses on tritium production and does not evaluate the transport and eventual release of the tritium in a fast reactor system. However, if an order-of-magnitude increase in fast fission yields for tritium is confirmed, fission will become the dominant production source of tritium in fast reactors

  3. Fast Breeder Reactor studies

    International Nuclear Information System (INIS)

    Till, C.E.; Chang, Y.I.; Kittel, J.H.; Fauske, H.K.; Lineberry, M.J.; Stevenson, M.G.; Amundson, P.I.; Dance, K.D.

    1980-07-01

    This report is a compilation of Fast Breeder Reactor (FBR) resource documents prepared to provide the technical basis for the US contribution to the International Nuclear Fuel Cycle Evaluation. The eight separate parts deal with the alternative fast breeder reactor fuel cycles in terms of energy demand, resource base, technical potential and current status, safety, proliferation resistance, deployment, and nuclear safeguards. An Annex compares the cost of decommissioning light-water and fast breeder reactors. Separate abstracts are included for each of the parts

  4. Fast Breeder Reactor studies

    Energy Technology Data Exchange (ETDEWEB)

    Till, C.E.; Chang, Y.I.; Kittel, J.H.; Fauske, H.K.; Lineberry, M.J.; Stevenson, M.G.; Amundson, P.I.; Dance, K.D.

    1980-07-01

    This report is a compilation of Fast Breeder Reactor (FBR) resource documents prepared to provide the technical basis for the US contribution to the International Nuclear Fuel Cycle Evaluation. The eight separate parts deal with the alternative fast breeder reactor fuel cycles in terms of energy demand, resource base, technical potential and current status, safety, proliferation resistance, deployment, and nuclear safeguards. An Annex compares the cost of decommissioning light-water and fast breeder reactors. Separate abstracts are included for each of the parts.

  5. Genome-wide analysis of mutations in mutant lineages selected following fast-neutron irradiation mutagenesis of Arabidopsis thaliana

    KAUST Repository

    Belfield, E.J.; Gan, X.; Mithani, A.; Brown, C.; Jiang, C.; Franklin, K.; Alvey, E.; Wibowo, A.; Jung, M.; Bailey, K.; Kalwani, S.; Ragoussis, J.; Mott, R.; Harberd, N.P.

    2012-01-01

    Ionizing radiation has long been known to induce heritable mutagenic change in DNA sequence. However, the genome-wide effect of radiation is not well understood. Here we report the molecular properties and frequency of mutations in phenotypically selected mutant lines isolated following exposure of the genetic model flowering plant Arabidopsis thaliana to fast neutrons (FNs). Previous studies suggested that FNs predominantly induce deletions longer than a kilobase in A. thaliana. However, we found a higher frequency of single base substitution than deletion mutations. While the overall frequency and molecular spectrum of fast-neutron (FN)-induced single base substitutions differed substantially from those of "background" mutations arising spontaneously in laboratory-grown plants, G:C>A:T transitions were favored in both. We found that FN-induced G:C>A:T transitions were concentrated at pyrimidine dinucleotide sites, suggesting that FNs promote the formation of mutational covalent linkages between adjacent pyrimidine residues. In addition, we found that FNs induced more single base than large deletions, and that these single base deletions were possibly caused by replication slippage. Our observations provide an initial picture of the genome-wide molecular profile of mutations induced in A. thaliana by FN irradiation and are particularly informative of the nature and extent of genome-wide mutation in lines selected on the basis of mutant phenotypes from FN-mutagenized A. thaliana populations.

  6. Genome-wide analysis of mutations in mutant lineages selected following fast-neutron irradiation mutagenesis of Arabidopsis thaliana

    KAUST Repository

    Belfield, E.J.

    2012-04-12

    Ionizing radiation has long been known to induce heritable mutagenic change in DNA sequence. However, the genome-wide effect of radiation is not well understood. Here we report the molecular properties and frequency of mutations in phenotypically selected mutant lines isolated following exposure of the genetic model flowering plant Arabidopsis thaliana to fast neutrons (FNs). Previous studies suggested that FNs predominantly induce deletions longer than a kilobase in A. thaliana. However, we found a higher frequency of single base substitution than deletion mutations. While the overall frequency and molecular spectrum of fast-neutron (FN)-induced single base substitutions differed substantially from those of "background" mutations arising spontaneously in laboratory-grown plants, G:C>A:T transitions were favored in both. We found that FN-induced G:C>A:T transitions were concentrated at pyrimidine dinucleotide sites, suggesting that FNs promote the formation of mutational covalent linkages between adjacent pyrimidine residues. In addition, we found that FNs induced more single base than large deletions, and that these single base deletions were possibly caused by replication slippage. Our observations provide an initial picture of the genome-wide molecular profile of mutations induced in A. thaliana by FN irradiation and are particularly informative of the nature and extent of genome-wide mutation in lines selected on the basis of mutant phenotypes from FN-mutagenized A. thaliana populations.

  7. Ionization signals from diamond detectors in fast-neutron fields

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, C. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); CIVIDEC Instrumentation, Wien (Austria); Frais-Koelbl, H. [University of Applied Sciences, Wiener Neustadt (Austria); Griesmayer, E.; Kavrigin, P. [CIVIDEC Instrumentation, Wien (Austria); Vienna University of Technology, Wien (Austria)

    2016-09-15

    In this paper we introduce a novel analysis technique for measurements with single-crystal chemical vapor deposition (sCVD) diamond detectors in fast-neutron fields. This method exploits the unique electronic property of sCVD diamond sensors that the signal shape of the detector current is directly proportional to the initial ionization profile. In fast-neutron fields the diamond sensor acts simultaneously as target and sensor. The interaction of neutrons with the stable isotopes {sup 12}C and {sup 13}C is of interest for fast-neutron diagnostics. The measured signal shapes of detector current pulses are used to identify individual types of interactions in the diamond with the goal to select neutron-induced reactions in the diamond and to suppress neutron-induced background reactions as well as γ-background. The method is verified with experimental data from a measurement in a 14.3 MeV neutron beam at JRC-IRMM, Geel/Belgium, where the {sup 13}C(n, α){sup 10}Be reaction was successfully extracted from the dominating background of recoil protons and γ-rays and the energy resolution of the {sup 12}C(n, α){sup 9}Be reaction was substantially improved. The presented analysis technique is especially relevant for diagnostics in harsh radiation environments, like fission and fusion reactors. It allows to extract the neutron spectrum from the background, and is particularly applicable to neutron flux monitoring and neutron spectroscopy. (orig.)

  8. Fast multichannel analyser

    Energy Technology Data Exchange (ETDEWEB)

    Berry, A; Przybylski, M M; Sumner, I [Science Research Council, Daresbury (UK). Daresbury Lab.

    1982-10-01

    A fast multichannel analyser (MCA) capable of sampling at a rate of 10/sup 7/ s/sup -1/ has been developed. The instrument is based on an 8 bit parallel encoding analogue to digital converter (ADC) reading into a fast histogramming random access memory (RAM) system, giving 256 channels of 64 k count capacity. The prototype unit is in CAMAC format.

  9. Fast food tips (image)

    Science.gov (United States)

    ... challenge to eat healthy when going to a fast food place. In general, avoiding items that are deep ... challenge to eat healthy when going to a fast food place. In general, avoiding items that are deep ...

  10. A fast charge-integrating sample-and-hold circuit for fast decision-making with calorimeter arrays

    International Nuclear Information System (INIS)

    Schuler, G.

    1982-01-01

    This paper describes a fast charge-integrating sample-and-hold circuit, particularly suited to the fast trigger electronics used with large arrays of photomultipliers in total-energy measurements of high-energy particles interactions. During a gate logic pulse, the circuit charges a capacitor with the current fed into the signal input. The output voltage is equal to the voltage developed across the capacitor, which is held until a fast clear discharges the capacitor. The main characteristics of the fast-charge-integrating sample-and-hold circuit are: i) a conversion factor of 1 V/220 pC; ii) a droop rate of 4 mV/μs for a 50 Ω load; and iii) a 1 μs fast-clear time. (orig.)

  11. Fasting and Fast Food Diet Play an Opposite Role in Mice Brain Aging.

    Science.gov (United States)

    Castrogiovanni, Paola; Li Volti, Giovanni; Sanfilippo, Cristina; Tibullo, Daniele; Galvano, Fabio; Vecchio, Michele; Avola, Roberto; Barbagallo, Ignazio; Malaguarnera, Lucia; Castorina, Sergio; Musumeci, Giuseppe; Imbesi, Rosa; Di Rosa, Michelino

    2018-01-20

    Fasting may be exploited as a possible strategy for prevention and treatment of several diseases such as diabetes, obesity, and aging. On the other hand, high-fat diet (HFD) represents a risk factor for several diseases and increased mortality. The aim of the present study was to evaluate the impact of fasting on mouse brain aging transcriptome and how HFD regulates such pathways. We used the NCBI Gene Expression Omnibus (GEO) database, in order to identify suitable microarray datasets comparing mouse brain transcriptome under fasting or HFD vs aged mouse brain transcriptome. Three microarray datasets were selected for this study, GSE24504, GSE6285, and GSE8150, and the principal molecular mechanisms involved in this process were evaluated. This analysis showed that, regardless of fasting duration, mouse brain significantly expressed 21 and 30 upregulated and downregulated genes, respectively. The involved biological processes were related to cell cycle arrest, cell death inhibition, and regulation of cellular metabolism. Comparing mouse brain transcriptome under fasting and aged conditions, we found out that the number of genes in common increased with the duration of fasting (222 genes), peaking at 72 h. In addition, mouse brain transcriptome under HFD resembles for the 30% the one of the aged mice. Furthermore, several molecular processes were found to be shared between HFD and aging. In conclusion, we suggest that fasting and HFD play an opposite role in brain transcriptome of aged mice. Therefore, an intermittent diet could represent a possible clinical strategy to counteract aging, loss of memory, and neuroinflammation. Furthermore, low-fat diet leads to the inactivation of brain degenerative processes triggered by aging.

  12. Soft x-ray continuum radiation transmitted through metallic filters: An analytical approach to fast electron temperature measurements

    International Nuclear Information System (INIS)

    Delgado-Aparicio, L.; Hill, K.; Bitter, M.; Tritz, K.; Kramer, T.; Stutman, D.; Finkenthal, M.

    2010-01-01

    A new set of analytic formulas describes the transmission of soft x-ray continuum radiation through a metallic foil for its application to fast electron temperature measurements in fusion plasmas. This novel approach shows good agreement with numerical calculations over a wide range of plasma temperatures in contrast with the solutions obtained when using a transmission approximated by a single-Heaviside function [S. von Goeler et al., Rev. Sci. Instrum. 70, 599 (1999)]. The new analytic formulas can improve the interpretation of the experimental results and thus contribute in obtaining fast temperature measurements in between intermittent Thomson scattering data.

  13. Viability of acid-fast bacilli from γ- and UV-irradiated lepromatous armadillo tissues infected with mycobacterium leprae

    International Nuclear Information System (INIS)

    Dastidar, S.G.; Chakraborty, A.N.

    1992-01-01

    γ-irradiated splenic homogenates of armadillos infected with M. leprae proved sterile by conventional tests and media. However, on media for chemoautotrophy, these could repeatedly grow as a single type of acid-fast nocardioform bacterium like the unirradiated specimens, although with a much reduced count. In the slide culture, transition from the initial acid-fast bacilli (AFB)/coccoid bodies, to sporulating mycelia and granules in the final stage, could be observed sequentially. The γ-irradiated tissue specimens failed to yield any other mycobacterium/corynebacterium tested according to standard protocols. (author). 26 refs., 2 tabs., 1 fig

  14. A FRAMEWORK FOR INTERPRETING FAST RADIO TRANSIENTS SEARCH EXPERIMENTS: APPLICATION TO THE V-FASTR EXPERIMENT

    International Nuclear Information System (INIS)

    Trott, Cathryn M.; Tingay, Steven J.; Wayth, Randall B.; Macquart, Jean-Pierre R.; Palaniswamy, Divya; Thompson, David R.; Wagstaff, Kiri L.; Majid, Walid A.; Burke-Spolaor, Sarah; Deller, Adam T.; Brisken, Walter F.

    2013-01-01

    We define a framework for determining constraints on the detection rate of fast transient events from a population of underlying sources, with a view to incorporate beam shape, frequency effects, scattering effects, and detection efficiency into the metric. We then demonstrate a method for combining independent data sets into a single event rate constraint diagram, using a probabilistic approach to the limits on parameter space. We apply this new framework to present the latest results from the V-FASTR experiment, a commensal fast transients search using the Very Long Baseline Array (VLBA). In the 20 cm band, V-FASTR now has the ability to probe the regions of parameter space of importance for the observed Lorimer and Keane fast radio transient candidates by combining the information from observations with differing bandwidths, and properly accounting for the source dispersion measure, VLBA antenna beam shape, experiment time sampling, and stochastic nature of events. We then apply the framework to combine the results of the V-FASTR and Allen Telescope Array Fly's Eye experiments, demonstrating their complementarity. Expectations for fast transients experiments for the SKA Phase I dish array are then computed, and the impact of large differential bandwidths is discussed.

  15. FAST goes underground

    International Nuclear Information System (INIS)

    Fridlund, P.S.

    1985-01-01

    The FAST-M Cost Estimating Model is a parametric model designed to determine the costs associated with mining and subterranean operations. It is part of the FAST (Freiman Analysis of Systems Techniques) series of parametric models developed by Freiman Parametric Systems, Inc. The rising cost of fossil fuels has created a need for a method which could be used to determine and control costs in mining and subterranean operations. FAST-M fills this need and also provides scheduling information. The model works equally well for a variety of situations including underground vaults for hazardous waste storage, highway tunnels, and mass transit tunnels. In addition, costs for above ground structures and equipment can be calculated. The input for the model may be on a macro or a micro level. This allows the model to be used at various stages in a project. On the macro level, only general conditions and specifications need to be known. On the micro level, the smallest details may be included. As with other FAST models, reference cases are used to more accurately predict costs and scheduling. This paper will address how the model can be used for a variety of subterranean purposes

  16. Design and Optimization of Fast Switching Valves for Large Scale Digital Hydraulic Motors

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck

    The present thesis is on the design, analysis and optimization of fast switching valves for digital hydraulic motors with high power ratings. The need for such high power motors origins in the potential use of hydrostatic transmissions in wind turbine drive trains, as digital hydraulic machines...... have been shown to improve the overall efficiency and efficient operation range compared to traditional hydraulic machines. Digital hydraulic motors uses electronically controlled independent seat valves connected to the pressure chambers, which must be fast acting and exhibit low pressure losses...... to enable efficient operation. These valves are complex components to design, as multiple design aspects are present in these integrated valve units, with conflicting objectives and interdependencies. A preliminary study on a small scale single-cylinder digital hydraulic pump has initially been conducted...

  17. Fast Calorimeter Simulation in ATLAS

    CERN Document Server

    Schaarschmidt, Jana; The ATLAS collaboration

    2017-01-01

    Producing the very large samples of simulated events required by many physics and performance studies with the ATLAS detector using the full GEANT4 detector simulation is highly CPU intensive. Fast simulation tools are a useful way of reducing CPU requirements when detailed detector simulations are not needed. During the LHC Run-1, a fast calorimeter simulation (FastCaloSim) was successfully used in ATLAS. FastCaloSim provides a simulation of the particle energy response at the calorimeter read-out cell level, taking into account the detailed particle shower shapes and the correlations between the energy depositions in the various calorimeter layers. It is interfaced to the standard ATLAS digitization and reconstruction software, and it can be tuned to data more easily than GEANT4. It is 500 times faster than full simulation in the calorimeter system. Now an improved version of FastCaloSim is in development, incorporating the experience with the version used during Run-1. The new FastCaloSim makes use of mach...

  18. Direct Fast-Neutron Detection

    International Nuclear Information System (INIS)

    DC Stromswold; AJ Peurrung; RR Hansen; PL Reeder

    2000-01-01

    Direct fast-neutron detection is the detection of fast neutrons before they are moderated to thermal energy. We have investigated two approaches for using proton-recoil in plastic scintillators to detect fast neutrons and distinguish them from gamma-ray interactions. Both approaches use the difference in travel speed between neutrons and gamma rays as the basis for separating the types of events. In the first method, we examined the pulses generated during scattering in a plastic scintillator to see if they provide a means for distinguishing fast-neutron events from gamma-ray events. The slower speed of neutrons compared to gamma rays results in the production of broader pulses when neutrons scatter several times within a plastic scintillator. In contrast, gamma-ray interactions should produce narrow pulses, even if multiple scattering takes place, because the time between successive scattering is small. Experiments using a fast scintillator confirmed the presence of broader pulses from neutrons than from gamma rays. However, the difference in pulse widths between neutrons and gamma rays using the best commercially available scintillators was not sufficiently large to provide a practical means for distinguishing fast neutrons and gamma rays on a pulse-by-pulse basis. A faster scintillator is needed, and that scintillator might become available in the literature. Results of the pulse-width studies were presented in a previous report (peurrung et al. 1998), and they are only summarized here

  19. Anthropometric, biomechanical, and isokinetic strength predictors of ball release speed in high-performance cricket fast bowlers.

    Science.gov (United States)

    Wormgoor, Shohn; Harden, Lois; Mckinon, Warrick

    2010-07-01

    Fast bowling is fundamental to all forms of cricket. The purpose of this study was to identify parameters that contribute to high ball release speeds in cricket fast bowlers. We assessed anthropometric dimensions, concentric and eccentric isokinetic strength of selected knee and shoulder muscle groups, and specific aspects of technique from a single delivery in 28 high-performance fast bowlers (age 22.0 +/- 3.0 years, ball release speed 34.0 +/- 1.3 m s(-1)). Six 50-Hz cameras and the Ariel Performance Analysis System software were used to analyse the fast and accurate deliveries. Using Pearson's correlation, parameters that showed significant associations with ball release speed were identified. The findings suggest that greater front leg knee extension at ball release (r=0.52), shoulder alignment in the transverse plane rotated further away from the batsman at front foot strike (r=0.47), greater ankle height during the delivery stride (r=0.44), and greater shoulder extension strength (r=0.39) contribute significantly to higher ball release speeds. Predictor variables failed to allow their incorporation into a multivariate model, which is known to exist in less accomplished bowlers, suggesting that factors that determine ball release speed found in other groups may not apply to high-performance fast bowlers.

  20. FastStats: Child Health

    Science.gov (United States)

    ... Women’s Health State and Territorial Data Reproductive Health Contraceptive Use Infertility Reproductive Health Notice Regarding FastStats Mobile ... table 6 [PDF – 2.7 MB] Related FastStats Adolescent Health ADHD Asthma Infant Health More data: reports ...

  1. Initial angle resolved measurements of fast neutrals using a multichannel linear AXUV detector system on LHD

    International Nuclear Information System (INIS)

    Veshchev, E. A.; Ozaki, T.; Goncharov, P. R.; Sudo, S.

    2006-01-01

    A new multichannel diagnostic for fast ion distribution studies has been developed and successfully tested on the Large Helical Device (LHD) in different plasma heating conditions. The diagnostic is based on a linear array AXUV detector consisting of 20 segments, charge sensitive preamplifiers, and a set of pulse height analysis channels. The main advantage of this system is the possibility to make time, energy, and angle-resolved measurements of charge exchange neutral particles in a single plasma discharge. This feature makes the new diagnostic a very helpful and powerful tool intended to contribute to the understanding of fast ion behavior in a complex helical plasma geometry like the one of LHD

  2. Electrically Anisotropic Layered Perovskite Single Crystal

    KAUST Repository

    Li, Ting-You

    2016-04-01

    Organic-inorganic hybrid perovskites (OIHPs), which are promising materials for electronic and optoelectronic applications (1-10), have made into layered organic-inorganic hybrid perovskites (LOIHPs). These LOIHPs have been applied to thin-film transistors, solar cells and tunable wavelength phosphors (11-18). It is known that devices fabricated with single crystal exhibit the superior performance, which makes the growth of large-sized single crystals critical for future device applications (19-23). However, the difficulty in growing large-sized LOIHPs single crystal with superior electrical properties limits their practical applications. Here, we report a method to grow the centimeter-scaled LOIHP single crystal of [(HOC2H4NH3)2PbI4], demonstrating the potentials in mass production. After that, we reveal anisotropic electrical and optoelectronic properties which proved the carrier propagating along inorganic framework. The carrier mobility of in-inorganic-plane (in-plane) devices shows the average value of 45 cm2 V–1 s–1 which is about 100 times greater than the record of LOIHP devices (15), showing the importance of single crystal in device application. Moreover, the LOIHP single crystals show its ultra-short carrier lifetime of 42.7 ps and photoluminescence quantum efficiency (PLQE) of 25.4 %. We expect this report to be a start of LOIHPs for advanced applications in which the anisotropic properties are needed (24-25), and meets the demand of high-speed applications and fast-response applications.

  3. Research on a Pulmonary Nodule Segmentation Method Combining Fast Self-Adaptive FCM and Classification

    Directory of Open Access Journals (Sweden)

    Hui Liu

    2015-01-01

    Full Text Available The key problem of computer-aided diagnosis (CAD of lung cancer is to segment pathologically changed tissues fast and accurately. As pulmonary nodules are potential manifestation of lung cancer, we propose a fast and self-adaptive pulmonary nodules segmentation method based on a combination of FCM clustering and classification learning. The enhanced spatial function considers contributions to fuzzy membership from both the grayscale similarity between central pixels and single neighboring pixels and the spatial similarity between central pixels and neighborhood and improves effectively the convergence rate and self-adaptivity of the algorithm. Experimental results show that the proposed method can achieve more accurate segmentation of vascular adhesion, pleural adhesion, and ground glass opacity (GGO pulmonary nodules than other typical algorithms.

  4. A Fast and High-precision Orientation Algorithm for BeiDou Based on Dimensionality Reduction

    Directory of Open Access Journals (Sweden)

    ZHAO Jiaojiao

    2015-05-01

    Full Text Available A fast and high-precision orientation algorithm for BeiDou is proposed by deeply analyzing the constellation characteristics of BeiDou and GEO satellites features.With the advantage of good east-west geometry, the baseline vector candidate values were solved by the GEO satellites observations combined with the dimensionality reduction theory at first.Then, we use the ambiguity function to judge the values in order to obtain the optical baseline vector and get the wide lane integer ambiguities. On this basis, the B1 ambiguities were solved. Finally, the high-precision orientation was estimated by the determinating B1 ambiguities. This new algorithm not only can improve the ill-condition of traditional algorithm, but also can reduce the ambiguity search region to a great extent, thus calculating the integer ambiguities in a single-epoch.The algorithm is simulated by the actual BeiDou ephemeris and the result shows that the method is efficient and fast for orientation. It is capable of very high single-epoch success rate(99.31% and accurate attitude angle (the standard deviation of pitch and heading is respectively 0.07°and 0.13°in a real time and dynamic environment.

  5. Hispanics in Fast Food Jobs.

    Science.gov (United States)

    Charner, Ivan; Fraser, Bryna Shore

    A study examined the employment of Hispanics in the fast-food industry. Data were obtained from a national survey of employees at 279 fast-food restaurants from seven companies in which 194 (4.2 percent) of the 4,660 respondents reported being Hispanic. Compared with the total sample, Hispanic fast-food employees were slightly less likely to be…

  6. A Fast Radio Burst Search Method for VLBI Observation

    Science.gov (United States)

    Liu, Lei; Tong, Fengxian; Zheng, Weimin; Zhang, Juan; Tong, Li

    2018-02-01

    We introduce the cross-spectrum-based fast radio burst (FRB) search method for Very Long Baseline Interferometer (VLBI) observation. This method optimizes the fringe fitting scheme in geodetic VLBI data post-processing, which fully utilizes the cross-spectrum fringe phase information and therefore maximizes the power of single-pulse signals. Working with cross-spectrum greatly reduces the effect of radio frequency interference compared with using auto-power spectrum. Single-pulse detection confidence increases by cross-identifying detections from multiple baselines. By combining the power of multiple baselines, we may improve the detection sensitivity. Our method is similar to that of coherent beam forming, but without the computational expense to form a great number of beams to cover the whole field of view of our telescopes. The data processing pipeline designed for this method is easy to implement and parallelize, which can be deployed in various kinds of VLBI observations. In particular, we point out that VGOS observations are very suitable for FRB search.

  7. Each meal matters in the exposome: Biological and community considerations in fast-food-socioeconomic associations.

    Science.gov (United States)

    Prescott, Susan L; Logan, Alan C

    2017-11-01

    Advances in omics and microbiome technology have transformed the ways in which the biological consequences of life in the 'ecological theatre' can be visualized. Exposome science examines the total accumulated environmental exposures (both detrimental and beneficial) as a means to understand the response of the 'total organism to the total environment' over time. The repetitive stimulation of compensatory physiological responses (immune, cardiovascular, neuroendocrine) in response to stress - including sources of stress highly relevant to socioeconomic disadvantage - may lead to metabolic dysregulation and cellular damage, ultimately influencing behavior and disease. The collective toll of physiological wear and tear, known as allostatic load, is not paid equally throughout developed societies. It is paid in excess by the disadvantaged. In the context of fast-food, human and experimental research demonstrates that the biological response to a single fast-food-style meal - especially as mediated by the microbiome- is a product of the person's total lived experience, including the ability to buffer the fast-food meal-induced promotion of inflammation and oxidative stress. Emerging research indicates that each meal and its nutritional context matters. As we discuss, equal weekly visits to major fast-food outlets by the affluent and deprived do not translate into biological equivalency. Hence, debate concerning reducing fast-food outlets through policy - especially in disadvantaged neighborhoods where they are prevalent - requires a biological context. The fast-food establishment and fast-food meal - as they represent matters of food justice and press upon non-communicable disease risk - are far more than physical structures and collections of carbohydrate, fat, sugar and sodium. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  8. The fast code

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, L.N.; Wilson, R.E. [Oregon State Univ., Dept. of Mechanical Engineering, Corvallis, OR (United States)

    1996-09-01

    The FAST Code which is capable of determining structural loads on a flexible, teetering, horizontal axis wind turbine is described and comparisons of calculated loads with test data are given at two wind speeds for the ESI-80. The FAST Code models a two-bladed HAWT with degrees of freedom for blade bending, teeter, drive train flexibility, yaw, and windwise and crosswind tower motion. The code allows blade dimensions, stiffnesses, and weights to differ and models tower shadow, wind shear, and turbulence. Additionally, dynamic stall is included as are delta-3 and an underslung rotor. Load comparisons are made with ESI-80 test data in the form of power spectral density, rainflow counting, occurrence histograms, and azimuth averaged bin plots. It is concluded that agreement between the FAST Code and test results is good. (au)

  9. Fasting Lipoprotein Lipase Protein Levels Can Predict a Postmeal Increment of Triglyceride Levels in Fasting Normohypertriglyceridemic Subjects.

    Science.gov (United States)

    Tsuzaki, Kokoro; Kotani, Kazuhiko; Yamada, Kazunori; Sakane, Naoki

    2016-09-01

    Although a postprandial increment in triglyceride (TG) levels is considered to be a risk factor for atherogenesis, tests (e.g., fat load) to assess postprandial changes in TG levels cannot be easily applied to clinical practice. Therefore, fasting markers that predict postprandial TG states are needed to be developed. One current candidate is lipoprotein lipase (LPL) protein, a molecule that hydrides TGs. This study investigated whether fasting LPL levels could predict postprandial TG levels. A total of 17 subjects (11 men, 6 women, mean age 52 ± 11 years) with normotriglyceridemia during fasting underwent the meal test. Several fasting parameters, including LPL, were measured for the area under the curve of postprandial TGs (AUC-TG). The subjects' mean fasting TG level was 1.30 mmol/l, and their mean LPL level was 41.6 ng/ml. The subjects' TG levels increased after loading (they peaked after two postprandial hours). Stepwise multiple regression analysis demonstrated that fasting TG levels were a predictor of the AUC-TG. In addition, fasting LPL mass levels were found to be a predictor of the AUC-TG (β = 0.65, P fasting TG levels. Fasting LPL levels may be useful to predict postprandial TG increment in this population. © 2015 Wiley Periodicals, Inc.

  10. Fast multichannel analog storage system

    International Nuclear Information System (INIS)

    Freytag, D.R.

    1982-11-01

    A Multichannel Analog Storage System based on a commercial 32-channel parallel in/serial out (PISO) analog shift register is described. The basic unit is a single width CAMAC module containing 512 analog cells and the associated logic for data storage and subsequent readout. At sampling rates of up to 30 MHz the signals are strobed directly into the PISO. At higher rates signals are strobed into a fast presampling stage and subsequently transferred in block form into an array of PISO's. Sampling rates of 300 MHz have been achieved with the present device and 1000 MHz are possible with improved signal drivers. The system is well suited for simultaneous handling of many signal channels with moderate numbers of samples in each channel. RMS noise over full scale signal has been measured as 1:3000 (approx. = 11 bit). However, nonlinearities in the response and differences in sensitivity of the analog cells require an elaborate calibration system in order to realize 11 bit accuracy for the analog information

  11. The Fast Simulation Chain for ATLAS

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00399337; The ATLAS collaboration; Marshall, Zach

    2017-01-01

    In order to generate the huge number of Monte Carlo events that will be required by the ATLAS experiment over the next several runs, a very fast simulation is critical. Fast detector simulation alone, however, is insufficient: with very high numbers of simultaneous proton-proton collisions expected in Run 3 and beyond, the digitization (detector response emulation) and event reconstruction time quickly become comparable to the time required for detector simulation. The ATLAS Fast Chain simulation has been developed to solve this problem. Modules are implemented for fast simulation, fast digitization, and fast track reconstruction. The application is sufficiently fast—several orders of magnitude faster than the standard simulation—that the simultaneous proton-proton collisions can be generated during the simulation job, so Pythia8 also runs concurrently with the rest of the algorithms. The Fast Chain has been built to be extremely modular and flexible, so that each sample can be custom-tailored to match th...

  12. Fast food: unfriendly and unhealthy.

    Science.gov (United States)

    Stender, S; Dyerberg, J; Astrup, A

    2007-06-01

    Although nutrition experts might be able to navigate the menus of fast-food restaurant chains, and based on the nutritional information, compose apparently 'healthy' meals, there are still many reasons why frequent fast-food consumption at most chains is unhealthy and contributes to weight gain, obesity, type 2 diabetes and coronary artery disease. Fast food generally has a high-energy density, which, together with large portion sizes, induces over consumption of calories. In addition, we have found it to be a myth that the typical fast-food meal is the same worldwide. Chemical analyses of 74 samples of fast-food menus consisting of French fries and fried chicken (nuggets/hot wings) bought in McDonalds and KFC outlets in 35 countries in 2005-2006 showed that the total fat content of the same menu varies from 41 to 65 g at McDonalds and from 42 to 74 g at KFC. In addition, fast food from major chains in most countries still contains unacceptably high levels of industrially produced trans-fatty acids (IP-TFA). IP-TFA have powerful biological effects and may contribute to increased weight gain, abdominal obesity, type 2 diabetes and coronary artery disease. The food quality and portion size need to be improved before it is safe to eat frequently at most fast-food chains.

  13. FAST MRI breast screening revisited

    International Nuclear Information System (INIS)

    Jain, Manish; Jain, Arushi; Hyzy, Marek D.; Werth, Graziella

    2017-01-01

    Screening for breast cancer in high-risk women takes about 40 minutes to acquire an MRI scan and is time-intensive to report. There is recent interest in the performance of an abbreviated MRI protocol (FAST) in the screening setting. FAST scans have a reported negative predictive value of 99.8%. This study evaluates the false positive rates (FPR) and recall rates for FAST scans as compared to full diagnostic studies (FD). A database of all screening breast MRI scans performed at our institution between 30 June 2013 and 1 July 2014 (n = 591) was created by one of the researchers, who did not subsequently analyse the MRI scans. The T1W and first post-contrast and subtracted images from each of these scans (FAST protocol) were assessed by experienced breast MRI radiologists, blinded to the final diagnosis. The findings were then compared with the FD result. The recall rates were 6.6% for FAST scans and 5.8% for FD scans. FPR rates were 4.7% and 3.9% respectively. There is no statistically significant difference in the recall rates or FPR of FAST scans in comparison with full diagnostic studies. Given the absence of statistically significant difference in the FPR and recall rates in comparison with FD, FAST scans can replace FD for screening of breast cancer.

  14. Fast analytical scatter estimation using graphics processing units.

    Science.gov (United States)

    Ingleby, Harry; Lippuner, Jonas; Rickey, Daniel W; Li, Yue; Elbakri, Idris

    2015-01-01

    To develop a fast patient-specific analytical estimator of first-order Compton and Rayleigh scatter in cone-beam computed tomography, implemented using graphics processing units. The authors developed an analytical estimator for first-order Compton and Rayleigh scatter in a cone-beam computed tomography geometry. The estimator was coded using NVIDIA's CUDA environment for execution on an NVIDIA graphics processing unit. Performance of the analytical estimator was validated by comparison with high-count Monte Carlo simulations for two different numerical phantoms. Monoenergetic analytical simulations were compared with monoenergetic and polyenergetic Monte Carlo simulations. Analytical and Monte Carlo scatter estimates were compared both qualitatively, from visual inspection of images and profiles, and quantitatively, using a scaled root-mean-square difference metric. Reconstruction of simulated cone-beam projection data of an anthropomorphic breast phantom illustrated the potential of this method as a component of a scatter correction algorithm. The monoenergetic analytical and Monte Carlo scatter estimates showed very good agreement. The monoenergetic analytical estimates showed good agreement for Compton single scatter and reasonable agreement for Rayleigh single scatter when compared with polyenergetic Monte Carlo estimates. For a voxelized phantom with dimensions 128 × 128 × 128 voxels and a detector with 256 × 256 pixels, the analytical estimator required 669 seconds for a single projection, using a single NVIDIA 9800 GX2 video card. Accounting for first order scatter in cone-beam image reconstruction improves the contrast to noise ratio of the reconstructed images. The analytical scatter estimator, implemented using graphics processing units, provides rapid and accurate estimates of single scatter and with further acceleration and a method to account for multiple scatter may be useful for practical scatter correction schemes.

  15. When fast is better: protein folding fundamentals and mechanisms from ultrafast approaches.

    Science.gov (United States)

    Muñoz, Victor; Cerminara, Michele

    2016-09-01

    Protein folding research stalled for decades because conventional experiments indicated that proteins fold slowly and in single strokes, whereas theory predicted a complex interplay between dynamics and energetics resulting in myriad microscopic pathways. Ultrafast kinetic methods turned the field upside down by providing the means to probe fundamental aspects of folding, test theoretical predictions and benchmark simulations. Accordingly, experimentalists could measure the timescales for all relevant folding motions, determine the folding speed limit and confirm that folding barriers are entropic bottlenecks. Moreover, a catalogue of proteins that fold extremely fast (microseconds) could be identified. Such fast-folding proteins cross shallow free energy barriers or fold downhill, and thus unfold with minimal co-operativity (gradually). A new generation of thermodynamic methods has exploited this property to map folding landscapes, interaction networks and mechanisms at nearly atomic resolution. In parallel, modern molecular dynamics simulations have finally reached the timescales required to watch fast-folding proteins fold and unfold in silico All of these findings have buttressed the fundamentals of protein folding predicted by theory, and are now offering the first glimpses at the underlying mechanisms. Fast folding appears to also have functional implications as recent results connect downhill folding with intrinsically disordered proteins, their complex binding modes and ability to moonlight. These connections suggest that the coupling between downhill (un)folding and binding enables such protein domains to operate analogically as conformational rheostats. © 2016 The Author(s).

  16. Single muscle fiber adaptations with marathon training.

    Science.gov (United States)

    Trappe, Scott; Harber, Matthew; Creer, Andrew; Gallagher, Philip; Slivka, Dustin; Minchev, Kiril; Whitsett, David

    2006-09-01

    The purpose of this investigation was to characterize the effects of marathon training on single muscle fiber contractile function in a group of recreational runners. Muscle biopsies were obtained from the gastrocnemius muscle of seven individuals (22 +/- 1 yr, 177 +/- 3 cm, and 68 +/- 2 kg) before, after 13 wk of run training, and after 3 wk of taper. Slow-twitch myosin heavy chain [(MHC) I] and fast-twitch (MHC IIa) muscle fibers were analyzed for size, strength (P(o)), speed (V(o)), and power. The run training program led to the successful completion of a marathon (range 3 h 56 min to 5 h 35 min). Oxygen uptake during submaximal running and citrate synthase activity were improved (P training program. Muscle fiber size declined (P training. P(o) was maintained in both fiber types with training and increased (P 60% increase (P training and was unchanged in MHC IIa fibers. Peak power increased (P training with a further increase (P marathon training decreased slow-twitch and fast-twitch muscle fiber size but that it maintained or improved the functional profile of these fibers. A taper period before the marathon further improved the functional profile of the muscle, which was targeted to the fast-twitch muscle fibers.

  17. Feature-fused SSD: fast detection for small objects

    Science.gov (United States)

    Cao, Guimei; Xie, Xuemei; Yang, Wenzhe; Liao, Quan; Shi, Guangming; Wu, Jinjian

    2018-04-01

    Small objects detection is a challenging task in computer vision due to its limited resolution and information. In order to solve this problem, the majority of existing methods sacrifice speed for improvement in accuracy. In this paper, we aim to detect small objects at a fast speed, using the best object detector Single Shot Multibox Detector (SSD) with respect to accuracy-vs-speed trade-off as base architecture. We propose a multi-level feature fusion method for introducing contextual information in SSD, in order to improve the accuracy for small objects. In detailed fusion operation, we design two feature fusion modules, concatenation module and element-sum module, different in the way of adding contextual information. Experimental results show that these two fusion modules obtain higher mAP on PASCAL VOC2007 than baseline SSD by 1.6 and 1.7 points respectively, especially with 2-3 points improvement on some small objects categories. The testing speed of them is 43 and 40 FPS respectively, superior to the state of the art Deconvolutional single shot detector (DSSD) by 29.4 and 26.4 FPS.

  18. Interactive effects of reward sensitivity and residential fast-food restaurant exposure on fast-food consumption.

    Science.gov (United States)

    Paquet, Catherine; Daniel, Mark; Knäuper, Bärbel; Gauvin, Lise; Kestens, Yan; Dubé, Laurette

    2010-03-01

    Local fast-food environments have been increasingly linked to obesity and related outcomes. Individuals who are more sensitive to reward-related cues might be more responsive to such environments. This study aimed to assess the moderating role of sensitivity to reward on the relation between residential fast-food restaurant exposure and fast-food consumption. Four hundred fifteen individuals (49.6% men; mean age: 34.7 y) were sampled from 7 Montreal census tracts stratified by socioeconomic status and French/English language. The frequency of fast-food restaurant visits in the previous week was self-reported. Sensitivity to reward was self-reported by using the Behavioral Activation System (BAS) scale. Fast-food restaurant exposure within 500 m of the participants' residence was determined by using a Geographic Information System. Main and interactive effects of the BAS and fast-food restaurant exposure on fast-food consumption were tested with logistic regression models that accounted for clustering of observations and participants' age, sex, education, and household income. Regression results showed a significant interaction between BAS and fast-food restaurant exposure (P food restaurant exposure and consumption was positive for the highest tertile (odds ratio: 1.49; 95% CI: 1.20, 1.84; P < 0.001) but null for the intermediate (odds ratio: 1.03; 95% CI: 0.80, 1.34; P = 0.81) and lowest (odds ratio: 0.84; 95% CI: 0.51, 1.37; P = 0.49) tertiles. Reward-sensitive individuals may be more responsive to unhealthful cues in their immediate environment.

  19. Fast-food intake and perceived and objective measures of the local fast-food environment in adolescents.

    Science.gov (United States)

    Svastisalee, Chalida; Pagh Pedersen, Trine; Schipperijn, Jasper; Jørgensen, Sanne Ellegaard; Holstein, Bjørn E; Krølner, Rikke

    2016-02-01

    We examined associations between fast-food intake and perceived and objective fast-food outlet exposure. Information from the Health Behaviours in School-aged Children Study was linked to fast-food outlets in seventy-five school neighbourhoods. We used multivariate multilevel logistic regression analyses to examine associations between at least weekly fast-food intake and perceived and objective fast-food outlet measures. Data represent 4642 adolescents (aged 11-15 years) in Denmark. Boys reporting two or more fast-food outlets had 34% higher odds consuming fast food at least weekly. We detected higher odds of at least weekly fast-food intake among 15-year-old 9th graders (ORall=1.74; 95% CI 1.40, 2.18; ORboys=2.20; 95% CI 1.66, 2.91; ORgirls=1.41; 95% CI 1.03, 1.92), Danish speakers (ORall=2.32; 95% CI 1.68, 3.19; ORboys=2.58; 95% CI 1.69, 3.93; ORgirls=2.37; 95% CI 1.46, 3.84) and those travelling 15 min or less to school (ORall=1.21; 95% CI 1.00, 1.46; ORgirls=1.44; 95% CI 1.08, 1.93) compared with 11-year-old 5th graders, non-Danish speakers and those with longer travel times. Boys from middle- (OR=1.28; 95% CI 1.00, 1.65) and girls from low-income families (OR=1.46; 95% CI 1.05, 2.04) had higher odds of at least weekly fast-food intake compared with those from high-income backgrounds. Girls attending schools with canteens (OR=1.47; 95% CI 1.00, 2.15) had higher odds of at least weekly fast-food intake than girls at schools without canteens. The present study demonstrates that perceived food outlets may impact fast-food intake in boys while proximity impacts intake in girls. Public health planning could target food environments that emphasize a better understanding of how adolescents use local resources.

  20. Energy-resolved fast neutron resonance radiography at CSNS

    Science.gov (United States)

    Tan, Zhixin; Tang, Jingyu; Jing, Hantao; Fan, Ruirui; Li, Qiang; Ning, Changjun; Bao, Jie; Ruan, Xichao; Luan, Guangyuan; Feng, Changqin; Zhang, Xianpeng

    2018-05-01

    The white neutron beamline at the China Spallation Neutron Source will be used mainly for nuclear data measurements. It will be characterized by high flux and broad energy spectra. To exploit the beamline as a neutron imaging source, we propose a liquid scintillator fiber array for fast neutron resonance radiography. The fiber detector unit has a small exposed area, which will limit the event counts and separate the events in time, thus satisfying the requirements for single-event time-of-flight (SEToF) measurement. The current study addresses the physical design criteria for ToF measurement, including flux estimation and detector response. Future development and potential application of the technology are also discussed.

  1. Platforms for Single-Cell Collection and Analysis

    Directory of Open Access Journals (Sweden)

    Lukas Valihrach

    2018-03-01

    Full Text Available Single-cell analysis has become an established method to study cell heterogeneity and for rare cell characterization. Despite the high cost and technical constraints, applications are increasing every year in all fields of biology. Following the trend, there is a tremendous development of tools for single-cell analysis, especially in the RNA sequencing field. Every improvement increases sensitivity and throughput. Collecting a large amount of data also stimulates the development of new approaches for bioinformatic analysis and interpretation. However, the essential requirement for any analysis is the collection of single cells of high quality. The single-cell isolation must be fast, effective, and gentle to maintain the native expression profiles. Classical methods for single-cell isolation are micromanipulation, microdissection, and fluorescence-activated cell sorting (FACS. In the last decade several new and highly efficient approaches have been developed, which not just supplement but may fully replace the traditional ones. These new techniques are based on microfluidic chips, droplets, micro-well plates, and automatic collection of cells using capillaries, magnets, an electric field, or a punching probe. In this review we summarize the current methods and developments in this field. We discuss the advantages of the different commercially available platforms and their applicability, and also provide remarks on future developments.

  2. Platforms for Single-Cell Collection and Analysis.

    Science.gov (United States)

    Valihrach, Lukas; Androvic, Peter; Kubista, Mikael

    2018-03-11

    Single-cell analysis has become an established method to study cell heterogeneity and for rare cell characterization. Despite the high cost and technical constraints, applications are increasing every year in all fields of biology. Following the trend, there is a tremendous development of tools for single-cell analysis, especially in the RNA sequencing field. Every improvement increases sensitivity and throughput. Collecting a large amount of data also stimulates the development of new approaches for bioinformatic analysis and interpretation. However, the essential requirement for any analysis is the collection of single cells of high quality. The single-cell isolation must be fast, effective, and gentle to maintain the native expression profiles. Classical methods for single-cell isolation are micromanipulation, microdissection, and fluorescence-activated cell sorting (FACS). In the last decade several new and highly efficient approaches have been developed, which not just supplement but may fully replace the traditional ones. These new techniques are based on microfluidic chips, droplets, micro-well plates, and automatic collection of cells using capillaries, magnets, an electric field, or a punching probe. In this review we summarize the current methods and developments in this field. We discuss the advantages of the different commercially available platforms and their applicability, and also provide remarks on future developments.

  3. Single photon detection and localization accuracy with an ebCMOS camera

    Energy Technology Data Exchange (ETDEWEB)

    Cajgfinger, T. [CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, Villeurbanne F-69622 (France); Dominjon, A., E-mail: agnes.dominjon@nao.ac.jp [Université de Lyon, Université de Lyon 1, Lyon 69003 France. (France); Barbier, R. [CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, Villeurbanne F-69622 (France); Université de Lyon, Université de Lyon 1, Lyon 69003 France. (France)

    2015-07-01

    The CMOS sensor technologies evolve very fast and offer today very promising solutions to existing issues facing by imaging camera systems. CMOS sensors are very attractive for fast and sensitive imaging thanks to their low pixel noise (1e-) and their possibility of backside illumination. The ebCMOS group of IPNL has produced a camera system dedicated to Low Light Level detection and based on a 640 kPixels ebCMOS with its acquisition system. After reminding the principle of detection of an ebCMOS and the characteristics of our prototype, we confront our camera to other imaging systems. We compare the identification efficiency and the localization accuracy of a point source by four different photo-detection devices: the scientific CMOS (sCMOS), the Charge Coupled Device (CDD), the Electron Multiplying CCD (emCCD) and the Electron Bombarded CMOS (ebCMOS). Our ebCMOS camera is able to identify a single photon source in less than 10 ms with a localization accuracy better than 1 µm. We report as well efficiency measurement and the false positive identification of the ebCMOS camera by identifying more than hundreds of single photon sources in parallel. About 700 spots are identified with a detection efficiency higher than 90% and a false positive percentage lower than 5. With these measurements, we show that our target tracking algorithm can be implemented in real time at 500 frames per second under a photon flux of the order of 8000 photons per frame. These results demonstrate that the ebCMOS camera concept with its single photon detection and target tracking algorithm is one of the best devices for low light and fast applications such as bioluminescence imaging, quantum dots tracking or adaptive optics.

  4. FAST

    DEFF Research Database (Denmark)

    Zuidmeer-Jongejan, Laurian; Fernandez-Rivas, Montserrat; Poulsen, Lars K.

    2012-01-01

    ABSTRACT: The FAST project (Food Allergy Specific Immunotherapy) aims at the development of safe and effective treatment of food allergies, targeting prevalent, persistent and severe allergy to fish and peach. Classical allergen-specific immunotherapy (SIT), using subcutaneous injections with aqu...

  5. Inertial picobalance reveals fast mass fluctuations in mammalian cells

    Science.gov (United States)

    Martínez-Martín, David; Fläschner, Gotthold; Gaub, Benjamin; Martin, Sascha; Newton, Richard; Beerli, Corina; Mercer, Jason; Gerber, Christoph; Müller, Daniel J.

    2017-10-01

    The regulation of size, volume and mass in living cells is physiologically important, and dysregulation of these parameters gives rise to many diseases. Cell mass is largely determined by the amount of water, proteins, lipids, carbohydrates and nucleic acids present in a cell, and is tightly linked to metabolism, proliferation and gene expression. Technologies have emerged in recent years that make it possible to track the masses of single suspended cells and adherent cells. However, it has not been possible to track individual adherent cells in physiological conditions at the mass and time resolutions required to observe fast cellular dynamics. Here we introduce a cell balance (a ‘picobalance’), based on an optically excited microresonator, that measures the total mass of single or multiple adherent cells in culture conditions over days with millisecond time resolution and picogram mass sensitivity. Using our technique, we observe that the mass of living mammalian cells fluctuates intrinsically by around one to four per cent over timescales of seconds throughout the cell cycle. Perturbation experiments link these mass fluctuations to the basic cellular processes of ATP synthesis and water transport. Furthermore, we show that growth and cell cycle progression are arrested in cells infected with vaccinia virus, but mass fluctuations continue until cell death. Our measurements suggest that all living cells show fast and subtle mass fluctuations throughout the cell cycle. As our cell balance is easy to handle and compatible with fluorescence microscopy, we anticipate that our approach will contribute to the understanding of cell mass regulation in various cell states and across timescales, which is important in areas including physiology, cancer research, stem-cell differentiation and drug discovery.

  6. Fast-slow asymptotics for a Markov chain model of fast sodium current

    Science.gov (United States)

    Starý, Tomáš; Biktashev, Vadim N.

    2017-09-01

    We explore the feasibility of using fast-slow asymptotics to eliminate the computational stiffness of discrete-state, continuous-time deterministic Markov chain models of ionic channels underlying cardiac excitability. We focus on a Markov chain model of fast sodium current, and investigate its asymptotic behaviour with respect to small parameters identified in different ways.

  7. Differential diagnosis of pituitary adenomas and Rathke's cleft cysts by diffusion-weighted MRI using single-shot fast spin echo technique

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Takumi; Izumiyama, Hitoshi; Fukuda, Ataru; Tanioka, Daisuke; Kunii, Norihiko; Komatsu, Daisuke; Fujita, Shogo; Ukisu, Ryutaro; Moritani, Toshio [Showa Univ., Tokyo (Japan). School of Medicine

    2002-09-01

    The purpose of the present study was to prospectively evaluate the diagnostic ability of diffusion-weighted magnetic resonance imaging (DWI) using single-shot fast spin echo (SSFSE) technique to discriminate pituitary adenomas from Rathke's cleft cysts. DWIs were obtained from 40 patients with pathologically proven pituitary macroadenomas and 15 patients with proven Rathke's cleft cysts. Pituitary adenomas were divided into 27 cases with solid components alone, five with non-hemorrhagic large cysts, and eight with intratumoral hemorrhage. On SSFSE DWI, solid components of pituitary adenomas revealed iso or slightly increased intensity and intratumoral hemorrhage showed higher intensity than normal brain parenchyma, whereas Rathke's cleft cysts and intratumoral cysts demonstrated very low intensity. SSFSE DWI did not display the susceptibility artifacts that are seen close to the skull base and sinonasal cavities on echo planar diffusion imaging. On the basis of our preliminary findings, DWI may enable us to differentiate pituitary adenomas with only solid components and hemorrhagic pituitary adenomas appearing hyperintense on T1-weighted images from Rathke's cleft cysts without administration of gadolinium-DTPA. SSFSE DWI appears to be a useful technique for characterizing pituitary diseases without the susceptibility artifacts. Our study is the first report to demonstrate the identification of pituitary disorders on SSFSE DWI. (author)

  8. Fast synchrotron and FEL beam monitors based on single-crystal diamond detectors and InGaAs/InAlAs quantum well devices

    Science.gov (United States)

    Antonelli, M.; Di Fraia, M.; Carrato, S.; Cautero, G.; Menk, R. H.; Jark, W. H.; Ganbold, T.; Biasiol, G.; Callegari, C.; Coreno, M.; De Sio, A.; Pace, E.

    2013-12-01

    Simultaneous photon-beam position and intensity monitoring is becoming of increasing importance for new-generation synchrotron radiation sources and free-electron lasers (FEL). Thus, novel concepts of beam diagnostics are required in order to keep such beams under control. From this perspective diamond is a promising material for the production of semitransparent in situ photon beam monitors, which can withstand the high dose rates occurring in such radiation facilities. Here, we report on the development of freestanding, single-crystal chemical-vapor-deposited diamond detectors with segmented electrodes. Due to their direct, low-energy band gap, InGaAs quantum well devices operated at room temperature may also be used as fast detectors for photons ranging from visible to X-ray. These features are valuable in low-energy and time-resolved FEL applications. In particular, a novel segmented InGaAs/InAlAs device has been developed and will be discussed. Dedicated measurements carried out on both these devices at the Elettra Synchrotron show their capability to monitor the position and the intensity of the photon beam with bunch-by-bunch temporal performances. Furthermore, preliminary tests have been performed on diamond detectors at the Fermi FEL, extracting quantitative intensity and position information for 100-fs-wide FEL pulses with a photon energy of 28.8 eV.

  9. Simulation of micromechanical behavior of polycrystals: finite elements versus fast Fourier transforms

    International Nuclear Information System (INIS)

    Prakash, A; Lebensohn, R A

    2009-01-01

    In this work, we compare finite element and fast Fourier transform approaches for the prediction of the micromechanical behavior of polycrystals. Both approaches are full-field approaches and use the same visco-plastic single crystal constitutive law. We investigate the texture and the heterogeneity of the inter- and intragranular stress and strain fields obtained from the two models. Additionally, we also look into their computational performance. Two cases—rolling of aluminum and wire drawing of tungsten—are used to evaluate the predictions of the two models. Results from both the models are similar, when large grain distortions do not occur in the polycrystal. The finite element simulations were found to be highly computationally intensive, in comparison with the fast Fourier transform simulations. Figure 9 was corrected in this article on the 25 August 2009. The corrected electronic version is identical to the print version

  10. Hamiltonian analysis of fast wave current drive in tokamak plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Becoulet, A; Fraboulet, D; Giruzzi, G; Moreau, D; Saoutic, B [Association Euratom-CEA, Centre d` Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Chinardet, J [CISI Ingenierie, Centre d` Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France)

    1993-12-01

    The Hamiltonian formalism is used to analyze the direct resonant interaction between the fast magnetosonic wave and the electrons in a tokamak plasma. The intrinsic stochasticity of the electron phase space trajectories is derived, and together with extrinsic de-correlation processes, assesses the validity of the quasilinear approximation for the kinetic studies of fast wave current drive (FWCD). A full-wave resolution of the Maxwell-Vlasov set of equations provides the exact pattern of the wave fields in a complete tokamak geometry, for a realistic antenna spectrum. The local quasilinear diffusion tensor is derived from the wave fields, and is used for a computation of the driven current and deposited power profiles, the current drive efficiency, including possible non-linear effects in the kinetic equation. Several applications of FWCD on existing and future machines are given, as well as results concerning combination of FWCD with other non inductive current drive methods. An analytical expression for the current drive efficiency is given in the high single-pass absorption regimes. (authors). 20 figs., 1 tab., 26 refs.

  11. Simple, fast and accurate two-diode model for photovoltaic modules

    Energy Technology Data Exchange (ETDEWEB)

    Ishaque, Kashif; Salam, Zainal; Taheri, Hamed [Faculty of Electrical Engineering, Universiti Teknologi Malaysia, UTM 81310, Skudai, Johor Bahru (Malaysia)

    2011-02-15

    This paper proposes an improved modeling approach for the two-diode model of photovoltaic (PV) module. The main contribution of this work is the simplification of the current equation, in which only four parameters are required, compared to six or more in the previously developed two-diode models. Furthermore the values of the series and parallel resistances are computed using a simple and fast iterative method. To validate the accuracy of the proposed model, six PV modules of different types (multi-crystalline, mono-crystalline and thin-film) from various manufacturers are tested. The performance of the model is evaluated against the popular single diode models. It is found that the proposed model is superior when subjected to irradiance and temperature variations. In particular the model matches very accurately for all important points of the I-V curves, i.e. the peak power, short-circuit current and open circuit voltage. The modeling method is useful for PV power converter designers and circuit simulator developers who require simple, fast yet accurate model for the PV module. (author)

  12. Hamiltonian analysis of fast wave current drive in tokamak plasmas

    International Nuclear Information System (INIS)

    Becoulet, A.; Fraboulet, D.; Giruzzi, G.; Moreau, D.; Saoutic, B.

    1993-12-01

    The Hamiltonian formalism is used to analyze the direct resonant interaction between the fast magnetosonic wave and the electrons in a tokamak plasma. The intrinsic stochasticity of the electron phase space trajectories is derived, and together with extrinsic de-correlation processes, assesses the validity of the quasilinear approximation for the kinetic studies of fast wave current drive (FWCD). A full-wave resolution of the Maxwell-Vlasov set of equations provides the exact pattern of the wave fields in a complete tokamak geometry, for a realistic antenna spectrum. The local quasilinear diffusion tensor is derived from the wave fields, and is used for a computation of the driven current and deposited power profiles, the current drive efficiency, including possible non-linear effects in the kinetic equation. Several applications of FWCD on existing and future machines are given, as well as results concerning combination of FWCD with other non inductive current drive methods. An analytical expression for the current drive efficiency is given in the high single-pass absorption regimes. (authors). 20 figs., 1 tab., 26 refs

  13. Ultrahigh-brightness KrF laser system for fast ignition studies

    International Nuclear Information System (INIS)

    Shaw, M.J.; Ross, I.N.; Hooker, C.J.; Dodson, J.M.; Hirst, G.J.; Lister, J.M.D.; Divall, E.J.; Kidd, A.K.; Hancock, S.; Damerell, A.R.; Wyborn, B.E.

    1999-01-01

    The main requirements for a fast igniter laser beam are reviewed and shown to favour short wavelength and ultrahigh brightness. These requirements are met by the new KrF laser system at Rutherford Appleton Laboratory called TITANIA. TITANIA uses two schemes to enhance the laser beam brightness. The first is chirped pulse amplification which is used to enhance brightness by compressing the pulse into the femtosecond region. In this mode TITANIA produces in the region of 250 mJ on target in 700 fs. The second mode of operation uses a Raman technique for beam combining and beam clean-up which is designed to give a single beam of 80 Joules on target in a pulselength of 60 ps. In this scheme the KrF wavelength is Raman shifted to 268 nm. The Raman amplifiers will use gaseous rather than solid windows and experiments which demonstrate their feasibility will be described. A concept for a reactor scale fast igniter beam using the Raman technique will be discussed. (orig.)

  14. Effect of Fast Neutron to MA/PU Burning/Transmutation Characteristic Using a Fast Reactor

    International Nuclear Information System (INIS)

    Marsodi; Lasman, As Natio; Kimamoto, A.; Marsongkohadi; Zaki, S.

    2003-01-01

    MA/Pu burning/transmutation has been studied and evaluated using fast neutrons. Generally, neutron density at this fast burner reactor and transmutation has spectrum energy level around 0.2 MeV with wide enough variation, i.e. from low neutron spectrum to its peak is 0.2 MeV. This neutron spectrum energy level depends on the kind of cooler material or fuel used. Neutron spectrum higher than fast power reactor neutron spectrum is found by means of changing oxide fuel by metallic fuel and changing natrium cooler material by metallic or gas cooler material. This evaluation is conducted by various variations in accordance with the kind of fuel or cooler, MA/Pu fractions and fuel comparison fraction with respect to its cooler in order to get better neutron usage and MA/Pu burning speed. Reactor calculation evaluation in this paper was conducted with 26-group nuclear data cross section energy spectrum. The main purpose of the discussion is to know the effect of fast neutrons to burning/transmutation MA/Pu using fast neutrons

  15. Distraction, not hunger, is associated with lower mood and lower perceived work performance on fast compared to non-fast days during intermittent fasting.

    Science.gov (United States)

    Appleton, Katherine M; Baker, Stephanie

    2015-06-01

    Using a repeated measures design, 16 females recorded hunger, distraction, mood and perceived work performance on two consecutive fast days, on two earlier and on two subsequent consecutive non-fast days, during intermittent fasting. Using regression analyses, low positive mood was associated with higher distraction (β = -0.38, p < 0.01), and lower perceived work performance was associated with higher distraction (β = -0.50, p < 0.01) and lower positive mood (β = 0.59, p = 0.01). No associations were found with hunger (largest β = -0.11, p = 0.15). Associations between mood, perceived work performance and distraction but not hunger mirror those found in traditional dieting and suggest no benefit for attention from intermittent fasting-type regimes. © The Author(s) 2015.

  16. Is fasting safe? A chart review of adverse events during medically supervised, water-only fasting.

    Science.gov (United States)

    Finnell, John S; Saul, Bradley C; Goldhamer, Alan C; Myers, Toshia R

    2018-02-20

    Evidence suggests that fasting, during which only water is consumed, results in potentially health promoting physiological effects. However, peer-reviewed research assessing the safety of water-only fasting is lacking. To address this, we conducted a chart review to describe adverse events (AEs) that occurred during medically supervised, water-only fasting. Electronic charts from patient visits to a residential medical facility from 2006 to 2011 were reviewed. Patients who were at least 21 years of age and water-only fasted for ≥2 consecutive days with a refeeding period equal to half of the fast length were included. Out of 2539 charts, 768 visits met our inclusion and exclusion criteria. AEs were abstracted from chart notes and classified according to CTCAE (v4.03) and MedDRA (v12.1) terminology. Descriptive analysis of AEs is reported. During the protocol period, the highest grade AE (HGAE) in 555 visits was a grade 2 event or lower, in 212 visits it was a grade 3 event, in 1 visit it was a grade 4 event, and there were no grade 5 events. There were 2 (0.002%) visits with a serious adverse event (SAE). The majority of AEs identified were mild (n = 4490, 75%) in nature and known reactions to fasting. To our knowledge, this is the most comprehensive analysis of AEs experienced during medically supervised, water-only fasting conducted to date. Overall, our data indicate that the majority of AEs experienced were mild to moderate and known reactions to fasting. This suggests that the protocol used in this study can be safely implemented in a medical setting with minimal risk of a SAE.

  17. Analytical model for fast-shock ignition

    International Nuclear Information System (INIS)

    Ghasemi, S. A.; Farahbod, A. H.; Sobhanian, S.

    2014-01-01

    A model and its improvements are introduced for a recently proposed approach to inertial confinement fusion, called fast-shock ignition (FSI). The analysis is based upon the gain models of fast ignition, shock ignition and considerations for the fast electrons penetration into the pre-compressed fuel to examine the formation of an effective central hot spot. Calculations of fast electrons penetration into the dense fuel show that if the initial electron kinetic energy is of the order ∼4.5 MeV, the electrons effectively reach the central part of the fuel. To evaluate more realistically the performance of FSI approach, we have used a quasi-two temperature electron energy distribution function of Strozzi (2012) and fast ignitor energy formula of Bellei (2013) that are consistent with 3D PIC simulations for different values of fast ignitor laser wavelength and coupling efficiency. The general advantages of fast-shock ignition in comparison with the shock ignition can be estimated to be better than 1.3 and it is seen that the best results can be obtained for the fuel mass around 1.5 mg, fast ignitor laser wavelength ∼0.3  micron and the shock ignitor energy weight factor about 0.25

  18. Radio-frequency reflectometry on an undoped AlGaAs/GaAs single electron transistor

    DEFF Research Database (Denmark)

    MacLeod, S. J.; See, A. M.; Keane, Z. K.

    2014-01-01

    Radio frequency reflectometry is demonstrated in a sub-micron undoped AlGaAs/GaAs device. Undoped single electron transistors (SETs) are attractive candidates to study single electron phenomena, due to their charge stability and robust electronic properties after thermal cycling. However......, these devices require a large top-gate, which is unsuitable for the fast and sensitive radio frequency reflectometry technique. Here, we demonstrate that rf reflectometry is possible in an undoped SET....

  19. Can fast-twitch muscle fibres be selectively recruited during lengthening contractions? Review and applications to sport movements.

    Science.gov (United States)

    Chalmers, Gordon R

    2008-01-01

    Literature examining the recruitment order of motor units during lengthening (eccentric) contractions was reviewed to determine if fast-twitch motor units can be active while lower threshold slow-twitch motor units are not active. Studies utilizing surface electromyogram (EMG) amplitude, single motor unit activity, spike amplitude-frequency analyses, EMG power spectrum, mechanomyographic, and phosphocreatine-to-creatine ratio (PCr/Cr) techniques were reviewed. Only single motor unit and PCr/Cr data were found to be suitable to address the goals of this review. Nine of ten single motor unit studies, examining joint movement velocities up to 225 degrees/s and forces up to 53% of a maximum voluntary contraction, found that the size principle of motor unit recruitment applied during lengthening contractions. Deviation from the size principle was demonstrated by one study examining movements within a small range of low velocities and modest forces, although other studies examining similar low forces and lengthening velocities reported size-ordered recruitment. The PCr/Cr data demonstrated the activation of all fibre types in lengthening maximal contractions. Most evidence indicates that for lengthening contractions of a wide range of efforts and speeds, fast-twitch muscle fibres cannot be selectively recruited without activity of the slow-twitch fibres of the same muscle.

  20. Power from plutonium: fast reactor fuel

    International Nuclear Information System (INIS)

    Bishop, J.F.W.

    1981-01-01

    Points of similarity and of difference between fast reactor fuel and fuels for AGR and PWR plants are established. The flow of uranium and plutonium in fast and thermal systems is also mentioned, establishing the role of the fast reactor as a plutonium burner. A historical perspective of fast reactors is given in which the substantial experience accumulated in test and prototype is indicated and it is noted that fast reactors have now entered the commercial phase. The relevance of the data obtained in the test and prototype reactors to the behaviour of commercial fast reactor fuel is considered. The design concepts employed in fuel are reviewed, including sections on core support styles, pin support and pin detail. This is followed by a discussion of current issues under the headings of manufacture, performance and reprocessing. This section includes a consideration of gel fuel, achievable burn-up, irradiation induced distortions and material choices, fuel form, and fuel failure mechanisms. Future development possibilities are also discussed and the Paper concludes with a view on the logic of a UK fast reactor strategy. (U.K.)